WorldWideScience

Sample records for evaluating electrically insulating

  1. Electric fields and electrical insulation

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson

    2002-01-01

    The adoption of a field-theoretical approach to problems arising in the framework of electrical insulation is discussed with reference to six main topics, which have been addressed over the last 30 years. These include uniform field electrodes, Green's differential equation, electrode surface...... roughness, induced charge, electrostatic probes, and partial discharge transients, together with several follow-on aspects. Each topic is introduced and thereafter the progress achieved through the use of a field-theoretical approach is reviewed. Because the topics cover a wide spectrum of conditions......, it is amply demonstrated that such an approach can lead to significant progress in many areas of electrical insulation....

  2. Insulation assembly for electric machine

    Science.gov (United States)

    Rhoads, Frederick W.; Titmuss, David F.; Parish, Harold; Campbell, John D.

    2013-10-15

    An insulation assembly is provided that includes a generally annularly-shaped main body and at least two spaced-apart fingers extending radially inwards from the main body. The spaced-apart fingers define a gap between the fingers. A slot liner may be inserted within the gap. The main body may include a plurality of circumferentially distributed segments. Each one of the plurality of segments may be operatively connected to another of the plurality of segments to form the continuous main body. The slot liner may be formed as a single extruded piece defining a plurality of cavities. A plurality of conductors (extendable from the stator assembly) may be axially inserted within a respective one of the plurality of cavities. The insulation assembly electrically isolates the conductors in the electric motor from the stator stack and from other conductors.

  3. Electrically Tunable Magnetism in Magnetic Topological Insulators.

    Science.gov (United States)

    Wang, Jing; Lian, Biao; Zhang, Shou-Cheng

    2015-07-17

    The external controllability of the magnetic properties in topological insulators would be important both for fundamental and practical interests. Here we predict the electric-field control of ferromagnetism in a thin film of insulating magnetic topological insulators. The decrease of band inversion by the application of electric fields results in a reduction of magnetic susceptibility, and hence in the modification of magnetism. Remarkably, the electric field could even induce the magnetic quantum phase transition from ferromagnetism to paramagnetism. We further propose a transistor device in which the dissipationless charge transport of chiral edge states is controlled by an electric field. In particular, the field-controlled ferromagnetism in a magnetic topological insulator can be used for voltage based writing of magnetic random access memories in magnetic tunnel junctions. The simultaneous electrical control of magnetic order and chiral edge transport in such devices may lead to electronic and spintronic applications for topological insulators.

  4. Electrically Tunable Magnetism in Magnetic Topological Insulators

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jing; Lian, Biao; Zhang, Shou-Cheng

    2015-07-14

    The external controllability of the magnetic properties in topological insulators would be important both for fundamental and practical interests. Here we predict the electric-field control of ferromagnetism in a thin film of insulating magnetic topological insulators. The decrease of band inversion by the application of electric fields results in a reduction of magnetic susceptibility, and hence in the modification of magnetism. Remarkably, the electric field could even induce the magnetic quantum phase transition from ferromagnetism to paramagnetism. We further propose a transistor device in which the dissipationless charge transport of chiral edge states is controlled by an electric field. In particular, the field-controlled ferromagnetism in a magnetic topological insulator can be used for voltage based writing of magnetic random access memories in magnetic tunnel junctions. The simultaneous electrical control of magnetic order and chiral edge transport in such devices may lead to electronic and spintronic applications for topological insulators.

  5. Electrical insulator assembly with oxygen permeation barrier

    Science.gov (United States)

    Van Der Beck, Roland R.; Bond, James A.

    1994-01-01

    A high-voltage electrical insulator (21) for electrically insulating a thermoelectric module (17) in a spacecraft from a niobium-1% zirconium alloy wall (11) of a heat exchanger (13) filled with liquid lithium (16) while providing good thermal conductivity between the heat exchanger and the thermoelectric module. The insulator (21) has a single crystal alumina layer (SxAl.sub.2 O.sub.3, sapphire) with a niobium foil layer (32) bonded thereto on the surface of the alumina crystal (26) facing the heat exchanger wall (11), and a molybdenum layer (31) bonded to the niobium layer (32) to act as an oxygen permeation barrier to preclude the oxygen depleting effects of the lithium from causing undesirable niobium-aluminum intermetallic layers near the alumina-niobium interface.

  6. Self-Healable Electrical Insulation for High Voltage Applications

    Science.gov (United States)

    Williams, Tiffany S.

    2017-01-01

    Polymeric aircraft electrical insulation normally degrades by partial discharge with increasing voltage, which causes excessive localized Joule heating in the material and ultimately leads to dielectric failure of the insulator through thermal breakdown. Developing self-healing insulation could be a viable option to mitigate permanent mechanical degradation, thus increasing the longevity of the insulation. Instead of relying on catalyst and monomer-filled microcapsules to crack, flow, and cure at the damaged sites described in well-published mechanisms, establishment of ionic crosslinks could allow for multiple healing events to occur with the added benefit of achieving full recovery strength under certain thermal environments. This could be possible if the operating temperature of the insulator is the same as or close to the temperature where ionic crosslinks are formed. Surlyn, a commercial material with ionic crosslinks, was investigated as a candidate self-healing insulator based off prior demonstrations of self-healing behavior. Thin films of varying thicknesses were investigated and the effects of thickness on the dielectric strength were evaluated and compared to representative polymer insulators. The effects of thermal conditioning on the recovery strength and healing were observed as a function of time following dielectric breakdown. Moisture absorption was also studied to determine if moisture absorption rates in Surlyn were lower than that of common polyimides.

  7. Modification of electrical properties of topological insulators

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Peter Anand

    2017-08-29

    Ion implantation or deposition can be used to modify the bulk electrical properties of topological insulators. More particularly, ion implantation or deposition can be used to compensate for the non-zero bulk conductivity due to extrinsic charge carriers. The direct implantation of deposition/annealing of dopants allows better control over carrier concentrations for the purposes of achieving low bulk conductivity. Ion implantation or deposition enables the fabrication of inhomogeneously doped structures, enabling new types of device designs.

  8. Integrated Electrical Wire Insulation Repair System

    Science.gov (United States)

    Williams, Martha; Jolley, Scott; Gibson, Tracy; Parks, Steven

    2013-01-01

    An integrated system tool will allow a technician to easily and quickly repair damaged high-performance electrical wire insulation in the field. Low-melt polyimides have been developed that can be processed into thin films that work well in the repair of damaged polyimide or fluoropolymer insulated electrical wiring. Such thin films can be used in wire insulation repairs by affixing a film of this low-melt polyimide to the damaged wire, and heating the film to effect melting, flow, and cure of the film. The resulting repair is robust, lightweight, and small in volume. The heating of this repair film is accomplished with the use of a common electrical soldering tool that has been modified with a special head or tip that can accommodate the size of wire being repaired. This repair method can furthermore be simplified for the repair technician by providing replaceable or disposable soldering tool heads that have repair film already "loaded" and ready for use. The soldering tool heating device can also be equipped with a battery power supply that will allow its use in areas where plug-in current is not available

  9. 30 CFR 77.503 - Electric conductors; capacity and insulation.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric conductors; capacity and insulation... UNDERGROUND COAL MINES Electrical Equipment-General § 77.503 Electric conductors; capacity and insulation. Electric conductors shall be sufficient in size and have adequate current carrying capacity and be of such...

  10. 30 CFR 75.513 - Electric conductor; capacity and insulation.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric conductor; capacity and insulation. 75... MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.513 Electric conductor; capacity and insulation. All electric conductors shall be sufficient in...

  11. High voltage and electrical insulation engineering

    CERN Document Server

    Arora, Ravindra

    2011-01-01

    "The book is written for students as well as for teachers and researchers in the field of High Voltage and Insulation Engineering. It is based on the advance level courses conducted at TU Dresden, Germany and Indian Institute of Technology Kanpur, India. The book has a novel approach describing the fundamental concept of field dependent behavior of dielectrics subjected to high voltage. There is no other book in the field of high voltage engineering following this new approach in describing the behavior of dielectrics. The contents begin with the description of fundamental terminology in the subject of high voltage engineering. It is followed by the classification of electric fields and the techniques of field estimation. Performance of gaseous, liquid and solid dielectrics under different field conditions is described in the subsequent chapters. Separate chapters on vacuum as insulation and the lightning phenomenon are included"--

  12. Effects of thermal insulation on electrical connections and outlet boxes

    Science.gov (United States)

    Beausoliel, R. W.; Clifton, J. R.; Meese, W. J.

    1981-04-01

    When residential walls are retrofitted with foamed-in urea formaldehyde or blown-in cellulose thermal insulations, the insulation may enter electrical outlet and switch boxes. The effects of these thermal insulations on the durability of electrical components were studied. These studies were carried out at 44, 75, and 96 percent relative humidities with test periods between one and twelve months. Laboratory test methods were developed and tests performed to determine the electrical and corrosive effects of urea formaldehyde and cellulose thermal insulation contained in electrical outlet and switch boxes.

  13. Testing to evaluate synergistic effects from LOCA environments. Test IX. Simultaneous mode; cables, splice assemblies, and electrical insulation samples

    Energy Technology Data Exchange (ETDEWEB)

    Thome, F.V.

    1978-04-01

    This test was conducted to complement Test VIII which was a sequential test of cables, cable splices, and insulation samples. In this test, the generic LOCA environments (radiation, temperature, pressure, chemical spray) were simulated and simultaneously applied to the test items. There were no failures of any assemblies and all were able to function at rated current and voltage throughout the entire test. An additional parameter, dissipation factor, was monitored in this test and when used in conjunction with capacitance, provided a better indication of insulation degradation.

  14. Electrical control of spin in topological insulators

    Science.gov (United States)

    Chang, Kai

    2012-02-01

    All-electrical manipulation of electron spin in solids becomes a central issue of quantum information processing and quantum computing. The many previous proposals are based on spin-orbit interactions in semiconductors. Topological insulator, a strong spin-orbit coupling system, make it possible to control the spin transport electrically. Recent calculations proved that external electric fields can drive a HgTe quantum well from normal band insulator phase to topological insulator phase [1]. Since the topological edge states are robust against local perturbation, the controlling of edge states using local fields is a challenging task. We demonstrate that a p-n junction created electrically in HgTe quantum wells with inverted band structure exhibits interesting intraband and interband tunneling processes. We find a perfect intraband transmission for electrons injected perpendicularly to the interface of the p-n junction. The opacity and transparency of electrons through the p-n junction can be tuned by changing the incidence angle, the Fermi energy and the strength of the Rashba spin-orbit interaction (RSOI). The occurrence of a conductance plateau due to the formation of topological edge states in a quasi-one-dimensional p-n junction can be switched on and off by tuning the gate voltage. The spin orientation can be substantially rotated when the samples exhibit a moderately strong RSOI [2]. An electrical switching of the edge-state transport can also be realized using quantum point contacts in quantum spin Hall bars. The switch-on/off of the edge channel is caused by the finite size effect of the quantum point contact and therefore can be manipulated by tuning the voltage applied on the split gate [3,4]. The magnetic ions doped on the surface of 3D TI can be correlated through the helical electrons. The RKKY interaction mediated by the helical Dirac electrons consists of the Heisenberg-like, Ising-like, and Dzyaloshinskii-Moriya (DM)-like terms, which can be tuned

  15. Switching a normal insulator into a topological insulator via electric field with application to phosphorene.

    Science.gov (United States)

    Liu, Qihang; Zhang, Xiuwen; Abdalla, L B; Fazzio, Adalberto; Zunger, Alex

    2015-02-11

    The study of topological insulators has generally involved search of materials that have this property as an innate quality, distinct from normal insulators. Here we focus on the possibility of converting a normal insulator into a topological one by application of an external electric field that shifts different bands by different energies and induces a specific band inversion, which leads to a topological state. Phosphorene is a two-dimensional (2D) material that can be isolated through mechanical exfoliation from layered black phosphorus, but unlike graphene and silicene, single-layer phosphorene has a large band gap (1.5-2.2 eV). Thus, it was unsuspected to exhibit band inversion and the ensuing topological insulator behavior. Using first-principles calculations with applied perpendicular electric field F⊥ on few-layer phosphorene we predict a continuous transition from the normal insulator to a topological insulator and eventually to a metal as a function of F⊥. The tuning of topological behavior with electric field would lead to spin-separated, gapless edge states, that is, quantum spin Hall effect. This finding opens the possibility of converting normal insulating materials into topological ones via electric field and making a multifunctional "field effect topological transistor" that could manipulate simultaneously both spin and charge carrier. We use our results to formulate some design principles for looking for other 2D materials that could have such an electrical-induced topological transition.

  16. Evaluation of thermal insulation materials

    Science.gov (United States)

    Wilbers, O. J.; Conti, J. C.; Mcgee, J. V.; Mcpherson, J. I.

    1973-01-01

    Data was obtained on silicone-bonded fiberglass, isocyanurate foam, and two dozen other insulators. Materials were selected to withstand heat sterilization, outer space, and the Martian atmosphere. Significant environmental parameters were vibration, landing shock, and launch venting.

  17. Gaseous insulators for high voltage electrical equipment

    Science.gov (United States)

    Christophorou, Loucas G.; James, David R.; Pace, Marshall O.; Pai, Robert Y.

    1979-01-01

    Gaseous insulators comprise compounds having high attachment cross sections for electrons having energies in the 0-1.3 electron volt range. Multi-component gaseous insulators comprise compounds and mixtures having overall high electron attachment cross sections in the 0-1.3 electron volt range and moderating gases having high cross sections for inelastic interactions with electrons of energies 1-4 electron volts. Suitable electron attachment components include hexafluorobutyne, perfluorobutene-2, perfluorocyclobutane, perfluorodimethylcyclobutane, perfluorocyclohexene, perfluoromethylcyclohexane, hexafluorobutadiene, perfluoroheptene-1 and hexafluoroazomethane. Suitable moderating gases include N.sub.2, CO, CO.sub.2 and H.sub.2. The gaseous insulating mixture can also contain SF.sub.6, perfluoropropane and perfluorobenzene.

  18. Effect of electrically insulating materials on magnetically induced electrical currents in a tissue-like medium

    Science.gov (United States)

    Hoffmeister, Brent K.; Shores, Andrew R.; Banerjee, Shubho; Malkin, Robert A.

    2006-04-01

    Time varying magnetic fields can induce eddy currents in a conductor. Electrical currents also can be induced magnetically in the human body, and there has been considerable interest in the bioeffects of this phenomenon. We present an analytical model derived from Faraday's law and Coulomb's law that provides physical insight into how electrically insulating materials in a tissue-like medium redirect magnetically induced currents. The model shows that charge accumulates at the tissue-insulator interface to produce a secondary electric field. This field combines with the magnetically induced electric field to alter the net electric field in the vicinity of the insulator, causing the electric current to flow around the insulator. The model is supplemented by measurements of magnetically induced electric fields in a volume of physiologic saline solution. Good agreement is found among the model, the measurements, and a finite element analysis model of the experiment.

  19. New Techniques to Evaluate the Incendiary Behavior of Insulators

    Science.gov (United States)

    Buhler, Charles; Calle, Carlos; Clements, Sid; Trigwell, Steve; Ritz, Mindy

    2008-01-01

    New techniques for evaluating the incendiary behavior of insulators is presented. The onset of incendive brush discharges in air is evaluated using standard spark probe techniques for the case simulating approaches of an electrically grounded sphere to a charged insulator in the presence of a flammable atmosphere. However, this standard technique is unsuitable for the case of brush discharges that may occur during the charging-separation process for two insulator materials. We present experimental techniques to evaluate this hazard in the presence of a flammable atmosphere which is ideally suited to measure the incendiary nature of micro-discharges upon separation, a measurement never before performed. Other measurement techniques unique to this study include; surface potential measurements of insulators before, during and after contact and separation, as well as methods to verify fieldmeter calibrations using a charge insulator surface opposed to standard high voltage plates. Key words: Kapton polyimide film, incendiary discharges, brush discharges, contact and frictional electrification, ignition hazards, insulators, contact angle, surface potential measurements.

  20. 30 CFR 27.36 - Test for adequacy of electrical insulation and clearances.

    Science.gov (United States)

    2010-07-01

    ... Test for adequacy of electrical insulation and clearances. MSHA shall examine, and test in a manner it deems suitable, electrical insulation and clearances between electrical conductors to determine adequacy... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Test for adequacy of electrical insulation and...

  1. Industrial manufacturing of electric insulators; Fabricacion industrial de aisladores electricos

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, Lucia [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    Porcelain is the insulating material more extensively used for electric insulators manufacturing, due to its dielectric properties; nevertheless, it presents fragility problems of manufacture and of resistance to the thermal shock, among others. For this reason studies are being conducted for the substitution of porcelain in the electric insulators manufacturing. In this area, the Instituto de Investigaciones Electricas developed an improved insulating formulation - the polymeric concrete- and an industrial prototype machine for the manufacture of high voltage electric insulators for outdoors use. [Espanol] La porcelana es el material aislante electrico mas utilizado en la elaboracion de aisladores electricos, debido a sus propiedades dielectricas; sin embargo, presenta problemas de fragilidad, de fabricacion y de baja resistencia al choque termico, entre otros. Es por ello que se realizan estudios para sustituir la porcelana en la fabricacion de aisladores electricos. En este campo, el Instituto de Investigaciones Electricas desarrollo una formulacion aislante mejorada -el concreto polimerico- y una maquina prototipo industrial para fabricar aisladores electricos de alto voltaje para uso en exteriores.

  2. Electrically and Thermally Insulated Joint for Liquid Nitrogen Transfer

    DEFF Research Database (Denmark)

    Rasmussen, Carsten; Jensen, Kim Høj; Holbøll, Joachim T.

    1999-01-01

    A prototype of a superconducting cable is currently under construction. The cable conductor is cooled by liquid nitrogen in order to obtain superconductivity. The peripheral cooling circuit is kept at ground potential. This requires a joint which insulates both electrically and thermally...

  3. SAFETY ALERT: Electrical insulation defect on safety helmets

    CERN Multimedia

    HSE Unit

    2013-01-01

    Contrarily to the information provided until 31 May 2013, some “Euro Protection” safety helmets do not respect any of the requirements for electrical insulation.   This alert concerns the safety helmets identified under the following SCEM numbers: 50.43.30.050.4 white 50.43.30.060.2 yellow 50.43.30.070.0 blue This amounts up to several hundreds of helmets on the CERN site. People who need to wear an electrically insulated safety helmet for their activities, must from now on acquire a duly insulated item to be found on the CERN store under the following SCEM numbers: 50.43.30.210.6: Petzl Vertex ST Helmet (without vent) 50.43.30.300.1: IDRA Helmet with a visor for electrical work As for the people who do not need to wear an electrically insulated helmet for their activities, they can continue working with the aforementioned helmets. For your information, please take note of the maximum use limit of each helmet: “Euro Protection” Safety Helme...

  4. Measurement of full-field deformation induced by a dc electrical field in organic insulator films

    Directory of Open Access Journals (Sweden)

    Boudou L.

    2010-06-01

    Full Text Available Digital image correlation method (DIC using the correlation coefficient curve-fitting for full-field surface deformation measurements of organic insulator films is investigated in this work. First the validation of the technique was undertaken. The computer-generated speckle images and the measurement of coefficient of thermal expansion (CTE of aluminium are used to evaluate the measurement accuracy of the technique. In a second part the technique is applied to measure the mechanical deformation induced by electrical field application to organic insulators. For that Poly(ethylene naphthalene 2,6-dicarboxylate (PEN thin films were subjected to DC voltage stress and DIC provides the full-field induced deformations of the test films. The obtained results show that the DIC is a practical and robust tool for better comprehension of mechanical behaviour of the organic insulator films under electrical stress.

  5. CHARACTERIZATION OF ELECTRICAL PORCELAIN INSULATORS FROM LOCAL CLAYS

    OpenAIRE

    Okolo Chidiebere Cajetan; Ezechukwu O.A.; Olisakwe C.O.; Ezendokwelu C.E.; Umunna Chike

    2017-01-01

    In this thesis, the characterization of electrical porcelain insulators based on local clays has been investigated. Test samples were made by varying the quantities of feldspar and silica required to form a mouldable plastic body with each clay sample. The clay samples were bisque fired which is to 900°C and glazed before it was fired to 1250°C after air-drying. An electrical property such as dielectric strength (breakdown voltage) was determined for each test sample that survived the high te...

  6. GASSING OF THE ELECTRICAL INSULATING FLUIDS - A DETERMINANT FACTOR OF THE TRANSFORMERS SAFETY IN OPERATION

    Directory of Open Access Journals (Sweden)

    VOINA A.

    2017-06-01

    Full Text Available The influence on the quality of the electrical insulating fluids on the safety in operation of the transformers has been evaluated. After processing the comparative experimental data obtained by gas chromatography technique on 5 different sorts of electrical insulating fluids (a sort of vegetable oil with high oleic content and with addition of 0.5% antioxidant "functional model" - compared with two commercial sorts of mineral oil, 1 mainly vegetable commercial oil, 1 commercial synthetic ester, thermal aged in contact with electrical insulating paper and copper for electrical use, at 110 ± 3 °C for 1000 hours in closed vessels (limited access to atmospheric oxygen it has been found that at the transformers filled with mineral oils, the risk of explosion and fire is approx. 10 times higher than those filled with synthetic or vegetal ester. It has also been found that the ageing of the insulation paper is approx. 15 times slower in the synthetic and natural ester than in the mineral oils normally used in transformers.

  7. Comparison of Dissolved Gases in Mineral and Vegetable Insulating Oils under Typical Electrical and Thermal Faults

    OpenAIRE

    Chenmeng Xiang; Quan Zhou; Jian Li; Qingdan Huang; Haoyong Song; Zhaotao Zhang

    2016-01-01

    Dissolved gas analysis (DGA) is attracting greater and greater interest from researchers as a fault diagnostic tool for power transformers filled with vegetable insulating oils. This paper presents experimental results of dissolved gases in insulating oils under typical electrical and thermal faults in transformers. The tests covered three types of insulating oils, including two types of vegetable oil, which are camellia insulating oil, Envirotemp FR3, and a type of mineral insulating oil, to...

  8. Investigation of electrical responses to acupuncture stimulation: the effect of electrical grounding and insulation conditions.

    Science.gov (United States)

    Lee, Yong-Heum; Ryu, Yeon-Hang; Jung, Byungjo

    2009-03-01

    Acupuncture in Oriental medicine has been widely used as a core therapeutic method due to its minimal side-effects and therapeutic efficacy. However, the electrical response to acupuncture stimulation (ERAS) has not been clearly studied under acupuncture conditions that might affect the efficacy of acupuncture therapy. In this study, the ERAS was objectively investigated by measuring meridian electric potentials (MEPs) when the electrical grounding conditions of the operator and subject were varied, and when the insulation conditions of acupuncture needle were varied. MEPs between Sang-geoheo (ST37) and Ha-geoheo (ST39) of the Stomach Meridian (ST) were measured by stimulating Jok-samni (ST36) with an acupuncture needle. For non-insulated acupuncture stimulation (NIAS), the average MEP peak was 148.6 +/- 20.6 when neither the operator nor the subject were electrically grounded, 23.1 +/- 8.8 when the subject only was electrically grounded, 348 +/- 76.8 when the operator only was electrically grounded, and 19.9 +/- 4.7 when both the operator and the subject were electrically grounded. The MEPs presented various magnitudes and patterns depending on the electrical grounding conditions. The MEP pattern was very similar to that of the charge and discharge of a capacitor. For insulated acupuncture stimulation (IAS), the average MEP peak was 20 +/- 4 in all electrical grounding conditions, which is not a significant electric response for acupuncture stimulation. In terms of electricity, this study verified that acupuncture therapy might be affected by acupuncture conditions such as (1) the electrical grounding condition of the operator and the subject and (2) the insulation condition of the acupuncture needle.

  9. Evaluation of Silicone Rubber Insulators used in High-Voltage Transmission Lines

    Science.gov (United States)

    Ul-Hamid, Anwar; Soufi, Khaled Y.; Al-Hamoudi, Ibrahim

    2008-04-01

    Three long-rod silicone rubber composite insulators used in 230 kV power transmission lines were evaluated for aging affects. The insulators were obtained from various outdoor desert locations within Saudi Arabia where they had been in service for 6 years. Surface degradation associated with the aging process was analyzed by using Scanning Electron Microscopy (SEM) coupled with Energy Dispersive X-ray Spectroscopy (EDS), Fourier Transform Infra-Red Spectroscopy (FTIR), and Electron Spectroscopy for Chemical Analysis (ESCA). Electrical performance of insulators was evaluated by Rapid Flashover Voltage Tests (RFVT) and Pollution Severity Measurement Tests. Depending on their locations of service, the samples exhibited various types of pollutants at their surfaces. The analysis indicated that the insulator material showed localized surface degradation while there was no evidence of micro-cracking. Furthermore, it was noted that the electrical performance of the insulators was not significantly affected by exposure during the in-service period.

  10. Electrically Induced Multiple Metal-Insulator Transitions in Oxide Nanodevices

    Science.gov (United States)

    del Valle, Javier; Kalcheim, Yoav; Trastoy, Juan; Charnukha, Aliaksei; Basov, Dimitri N.; Schuller, Ivan K.

    2017-11-01

    We show that electrical resistive switching can trigger the appearance of multiple metal-insulator transitions (MITs) in VO2 and V2O3 planar nanodevices. We have fabricated planar devices to electrically induce oxygen vacancy drift and filament formation. We show that oxygen migration can create ordered vanadium-oxide phases of varying stoichiometry with an intrinsic MIT, resulting in well-defined hysteresis loops in the R vs T characteristics of the device. We also show that oxygen migration induces oxide phases displaying correlated behaviors. Our results open up the possibility to electrically control the MIT, enabling alternative functionalities in memristive devices and allowing for alternative paradigms in neuromorphic computing or memory applications.

  11. Effects of RTV coating on the electrical performance of polymer insulator under lightning impulse voltage condition.

    Directory of Open Access Journals (Sweden)

    Farah Adilah Jamaludin

    Full Text Available Located near the equator, Malaysia is a country with one of the highest lightning densities in the world. Lightning contributes to 70% of the power outages in Malaysia and affects power equipment, automated network systems, causes data losses and monetary losses in the nation. Therefore, consideration of insulator evaluation under lightning impulses can be crucial to evaluate and attempt to overcome this issue. This paper presents a new approach to increase the electrical performance of polymer insulators using a Room Temperature Vulcanisation (RTV coating. The evaluation involves three different settings of polymer insulator, namely uncoated, RTV type 1, and RTV type 2 upper surface coatings. All the insulators were tested under three different conditions as dry, clean wet and salty under different impulse polarities using the even-rising test method. The voltage breakdown for each test was recorded. From the experiment, it was found that the effectiveness of the RTV coating application became apparent when tested under salty or polluted conditions. It increased the voltage withstand capabilities of the polymer insulator up to 50% from the basic uncoated insulator. Under dry and clean conditions, the RTV coating provided just a slight increase of the breakdown voltage. The increase in voltage breakdown capability decreased the probability of surface discharge and dry band arcing that could cause degradation of the polymeric material housing. The RTV type 1 coating was found to be more effective when performing under a lightning impulse. The findings might help the utility companies improve the performance of their insulators in order to increase power system reliability.

  12. Effects of RTV coating on the electrical performance of polymer insulator under lightning impulse voltage condition.

    Science.gov (United States)

    Jamaludin, Farah Adilah; Ab-Kadir, Mohd Zainal Abidin; Izadi, Mahdi; Azis, Norhafiz; Jasni, Jasronita; Abd-Rahman, Muhammad Syahmi

    2017-01-01

    Located near the equator, Malaysia is a country with one of the highest lightning densities in the world. Lightning contributes to 70% of the power outages in Malaysia and affects power equipment, automated network systems, causes data losses and monetary losses in the nation. Therefore, consideration of insulator evaluation under lightning impulses can be crucial to evaluate and attempt to overcome this issue. This paper presents a new approach to increase the electrical performance of polymer insulators using a Room Temperature Vulcanisation (RTV) coating. The evaluation involves three different settings of polymer insulator, namely uncoated, RTV type 1, and RTV type 2 upper surface coatings. All the insulators were tested under three different conditions as dry, clean wet and salty under different impulse polarities using the even-rising test method. The voltage breakdown for each test was recorded. From the experiment, it was found that the effectiveness of the RTV coating application became apparent when tested under salty or polluted conditions. It increased the voltage withstand capabilities of the polymer insulator up to 50% from the basic uncoated insulator. Under dry and clean conditions, the RTV coating provided just a slight increase of the breakdown voltage. The increase in voltage breakdown capability decreased the probability of surface discharge and dry band arcing that could cause degradation of the polymeric material housing. The RTV type 1 coating was found to be more effective when performing under a lightning impulse. The findings might help the utility companies improve the performance of their insulators in order to increase power system reliability.

  13. Effects of RTV coating on the electrical performance of polymer insulator under lightning impulse voltage condition

    Science.gov (United States)

    Jamaludin, Farah Adilah; Ab-Kadir, Mohd Zainal Abidin; Izadi, Mahdi; Azis, Norhafiz; Jasni, Jasronita; Abd-Rahman, Muhammad Syahmi

    2017-01-01

    Located near the equator, Malaysia is a country with one of the highest lightning densities in the world. Lightning contributes to 70% of the power outages in Malaysia and affects power equipment, automated network systems, causes data losses and monetary losses in the nation. Therefore, consideration of insulator evaluation under lightning impulses can be crucial to evaluate and attempt to overcome this issue. This paper presents a new approach to increase the electrical performance of polymer insulators using a Room Temperature Vulcanisation (RTV) coating. The evaluation involves three different settings of polymer insulator, namely uncoated, RTV type 1, and RTV type 2 upper surface coatings. All the insulators were tested under three different conditions as dry, clean wet and salty under different impulse polarities using the even-rising test method. The voltage breakdown for each test was recorded. From the experiment, it was found that the effectiveness of the RTV coating application became apparent when tested under salty or polluted conditions. It increased the voltage withstand capabilities of the polymer insulator up to 50% from the basic uncoated insulator. Under dry and clean conditions, the RTV coating provided just a slight increase of the breakdown voltage. The increase in voltage breakdown capability decreased the probability of surface discharge and dry band arcing that could cause degradation of the polymeric material housing. The RTV type 1 coating was found to be more effective when performing under a lightning impulse. The findings might help the utility companies improve the performance of their insulators in order to increase power system reliability. PMID:29136025

  14. Designing Predictive Diagnose Method for Insulation Resistance Degradation of the Electrical Power Cables from Neutral Insulated Power Networks

    Science.gov (United States)

    Dobra, R.; Pasculescu, D.; Risteiu, M.; Buica, G.; Jevremović, V.

    2017-06-01

    This paper describe some possibilities to minimize voltages switching-off risks from the mining power networks, in case of insulated resistance faults by using a predictive diagnose method. The cables from the neutral insulated power networks (underground mining) are designed to provide a flexible electrical connection between portable or mobile equipment and a point of supply, including main feeder cable for continuous miners, pump cable, and power supply cable. An electronic protection for insulated resistance of mining power cables can be made using this predictive strategy. The main role of electronic relays for insulation resistance degradation of the electrical power cables, from neutral insulated power networks, is to provide a permanent measurement of the insulated resistance between phases and ground, in order to switch-off voltage when the resistance value is below a standard value. The automat system of protection is able to signalize the failure and the human operator will be early informed about the switch-off power and will have time to take proper measures to fix the failure. This logic for fast and automat switch-off voltage without aprioristic announcement is suitable for the electrical installations, realizing so a protection against fires and explosion. It is presented an algorithm and an anticipative relay for insulated resistance control from three-phase low voltage installations with insulated neutral connection.

  15. Numerical Computation of Electric Field and Potential Along Silicone Rubber Insulators Under Contaminated and Dry Band Conditions

    Science.gov (United States)

    Arshad; Nekahi, A.; McMeekin, S. G.; Farzaneh, M.

    2016-09-01

    Electrical field distribution along the insulator surface is considered one of the important parameters for the performance evaluation of outdoor insulators. In this paper numerical simulations were carried out to investigate the electric field and potential distribution along silicone rubber insulators under various polluted and dry band conditions. Simulations were performed using commercially available simulation package Comsol Multiphysics based on the finite element method. Various pollution severity levels were simulated by changing the conductivity of pollution layer. Dry bands of 2 cm width were inserted at the high voltage end, ground end, middle part, shed, sheath, and at the junction of shed and sheath to investigate the effect of dry band location and width on electric field and potential distribution. Partial pollution conditions were simulated by applying pollution layer on the top and bottom surface respectively. It was observed from the simulation results that electric field intensity was higher at the metal electrode ends and at the junction of dry bands. Simulation results showed that potential distribution is nonlinear in the case of clean and partially polluted insulator and linear for uniform pollution layer. Dry band formation effect both potential and electric field distribution. Power dissipated along the insulator surface and the resultant heat generation was also studied. The results of this study could be useful in the selection of polymeric insulators for contaminated environments.

  16. Cloaking magnetic field and generating electric field with topological insulator and superconductor bi-layer sphere

    Directory of Open Access Journals (Sweden)

    Jin Xu

    2017-12-01

    Full Text Available When an electric field is applied on a topological insulator, not only the electric field is generated, but also the magnetic field is generated, vice versa. I designed topological insulator and superconductor bi-layer magnetic cloak, derived the electric field and magnetic field inside and outside the topological insulator and superconductor sphere. Simulation and calculation results show that the applied magnetic field is screened by the topological insulator and superconductor bi-layer, and the electric field is generated in the cloaked region.

  17. Electrical actuation of electrically conducting and insulating droplets using ac and dc voltages

    Science.gov (United States)

    Kumari, N.; Bahadur, V.; Garimella, S. V.

    2008-10-01

    Electrical actuation of liquid droplets at the microscale offers promising applications in the fields of microfluidics and lab-on-chip devices. Much prior research has targeted the electrical actuation of electrically conducting liquid droplets using dc voltages (classical electrowetting). Electrical actuation of conducting droplets using ac voltages and the actuation of insulating droplets (using dc or ac voltages) has remained relatively unexplored. This paper utilizes an energy-minimization-based analytical framework to study the electrical actuation of a liquid droplet (electrically conducting or insulating) under ac actuation. It is shown that the electromechanical regimes of classical electrowetting, electrowetting under ac actuation and insulating droplet actuation can be extracted from the generic electromechanical actuation framework, depending on the electrical properties of the droplet, the underlying dielectric layer and the frequency of the actuation voltage. This paper also presents experiments which quantify the influence of the ac frequency and the electrical properties of the droplet on its velocity under electrical actuation. The velocities of droplets moving between two parallel plates under ac actuation are experimentally measured; these velocities are then related to the actuation force on the droplet which is predicted by the electromechanical model developed in this work. It is seen that the droplet velocities are strongly dependent on the frequency of the ac actuation voltage; the cut-off ac frequency, above which the droplet fails to actuate, is experimentally determined and related to the electrical conductivity of the liquid. This paper then analyzes and directly compares the various electromechanical regimes for the actuation of droplets in microfluidic applications.

  18. Evaluation of Charge Storage and Decay in Spacecraft Insulators

    Science.gov (United States)

    Frederickson, Arthur; Benson, Charles; Bockman, James

    2003-01-01

    Two reports discuss methods for evaluating the magnitude of electrostatic charging that occurs in spacecraft dielectric materials (in particular, polyimides) during prolonged exposure to radiation in outer space. The reports describe experiments on the electrical resistivities and charge-storage properties of polyimide specimens in a dark, evacuated environment, both before and after 5-megarad exposures to rays from cobalt-60. The experiments were designed to measure these properties not under standard conditions prescribed for testing dielectrics in air but, rather, under conditions approximating those in the intended spacecraft applications. The results of the experiments showed that the electrical resistivities of the insulations as determined under these conditions are greater, by a factor of roughly a thousand, than those determined under the standard conditions and that the gamma irradiation reduced resistivities marginally.

  19. Condition Evaluation of Large Generator Stator Insulation Based on Partial Discharge Measurement

    Directory of Open Access Journals (Sweden)

    Ruihua Li

    2013-01-01

    Full Text Available The large generator faults are mostly from the stator insulation, which is aged by exposure to a combination of thermal, electrical, mechanical, and harsh environment stresses. Condition evaluation of stator insulation is an important measure of ensuring the safe operation and extending the remaining life of large generator. In this paper, a diagnosis method based on the partial discharge (PD measurement was used for the condition evaluation of the stator insulation. The statistical parameters of partial discharge phase resolved distribution were proposed to assess the aging condition of stator insulation. A partial least square (PLS approach was used to explore and extract relationships between the statistical parameters of partial discharge distribution with physical properties and performance such as electrical breakdown strength. Results of the PD testing and statistical analysis show that the statistical parameter Sk extent of partial discharge distribution changes much more remarkably with the aging time than do the other parameters. The statistical parameter Sk can be considered as a potential indicator of stator insulation aging. The PLS approach can effectively assess the stator insulation aging condition and can provide a predictive capability for the stator insulation diagnosis.

  20. Radiation cross-linking of small electrical wire insulator fabricated from NR/LDPE blends

    Energy Technology Data Exchange (ETDEWEB)

    Siri-Upathum, Chyagrit [Department of Nuclear Technology, Faculty of Engineering Chulalongkorn University, Bangkok 10330 (Thailand)], E-mail: chyagrit@chula.ac.th; Punnachaiya, Suvit [Department of Nuclear Technology, Faculty of Engineering Chulalongkorn University, Bangkok 10330 (Thailand)

    2007-12-15

    A low voltage, radiation-crosslinked wire insulator has been fabricated from blends of natural rubber block (STR-5L) and LDPE with phthalic anhydride (PA) as a compatibilizer. Physical properties of the NR/LDPE blend ratios of 50/50 and 60/40 with 0.5, 1.0, and 1.5 wt% PA were evaluated. The gel content increased as the radiation dose increased. Tensile at break exhibited a maximum value of 12 MPa at 120 kGy for 1.0 and 1.5 wt% PA of both blend ratios. A higher PA content yielded a higher modulus for the same blend ratio. Blends of 60/40 ratio with 1.0 wt% PA and 0.8 wt% antimony oxide flame retardant gave the highest limiting oxygen index (LOI) of >30% at above 150 kGy. Other electrical properties of the wire insulator were investigated. It was found that an insulator fabricated from a PA content of 1.0 wt% in the NR/LDPE blend ratio of 50/50, after gamma ray cross-linked at a dose of 180 kGy in low vacuum (1 mm Hg), met the Thai Industrial Standard 11-2531 for low voltage wire below 1.0 kV. To comply with the standard for vertical flame test, a more suitable flame retardant was needed for the insulator.

  1. Electrical detection of spin-momentum locking in topological insulators

    Science.gov (United States)

    Li, Connie; van't Erve, Olaf; Robinson, Jeremy; Li, Yaoyi; Li, Lian; Jonker, Berry

    2015-03-01

    One of the most striking properties of topological insulators (TIs) is that of spin-momentum locking - the spin of the TI surface state lies in-plane, and is locked at right angle to the carrier momentum. While anticipated by theory, direct electrical access to this spin system in a simple transport structure had been challenging, due to that the bulk is typically unintentionally doped and contributes to transport. Using a ferromagnet/tunnel barrier detector contact that preferentially probes surface/interface spins, we have demonstrated the first direct electrical detection of spin-momentum locking in the TI surface states in MBE-grown Bi2Se3. However, as the bulk carrier concentration for Bi2Se3 is typically in the 1019/cm3 range, the Fermi level is well within the conduction band, where a significant portion of the current is shunted through the bulk. Moving the Fermi level to within the gap is desirable to eliminate current shunting, as well as contribution from Rashba 2DEG states that may dilute the signal. These results, as well as how they affect the spin signal measured will be discussed at the meeting. Supported by NRL core funds and Nanoscience Institute.

  2. Insulation co-ordination in high-voltage electric power systems

    CERN Document Server

    Diesendorf, W

    2015-01-01

    Insulation Co-ordination in High-Voltage Electric Power Systems deals with the methods of insulation needed in different circumstances. The book covers topics such as overvoltages and lightning surges; disruptive discharge and withstand voltages; self-restoring and non-self-restoring insulation; lightning overvoltages on transmission lines; and the attenuation and distortion of lightning surges. Also covered in the book are topics such as the switching surge designs of transmission lines, as well as the insulation coordination of high-voltage stations. The text is recommended for electrical en

  3. Reaction and Protection of Electrical Wire Insulators in Atomic-oxygen Environments

    Science.gov (United States)

    Hung, Ching-Cheh; Cantrell, Gidget

    1994-01-01

    Atomic-oxygen erosion on spacecraft in low Earth orbit is an issue which is becoming increasingly important because of the growing number of spacecraft that will fly in the orbits which have high concentrations of atomic oxygen. In this investigation, the atomic-oxygen durability of three types of electrical wire insulation (carbon-based, fluoropolymer, and polysiloxane elastomer) were evaluated. These insulation materials were exposed to thermal-energy atomic oxygen, which was obtained by RF excitation of air at a pressure of 11-20 Pa. The effects of atomic-oxygen exposure on insulation materials indicate that all carbon-based materials erode at about the same rate as polyamide Kapton and, therefore, are not atomic-oxygen durable. However, the durability of fluoropolymers needs to be evaluated on a case by case basis because the erosion rates of fluoropolymers vary widely. For example, experimental data suggest the formation of atomic fluorine during atomic-oxygen amorphous-fluorocarbon reactions. Dimethyl polysiloxanes (silicone) do not lose mass during atomic-oxygen exposure, but develop silica surfaces which are under tension and frequently crack as a result of loss of methyl groups. However, if the silicone sample surfaces were properly pretreated to provide a certain roughness, atomic oxygen exposure resulted in a sturdy, non-cracked atomic-oxygen durable SiO2 layer. Since the surface does not crack during such silicone-atomic oxygen reaction, the crack-induced contamination by silicone can be reduced or completely stopped. Therefore, with proper pretreatment, silicone can be either a wire insulation material or a coating on wire insulation materials to provide atomic-oxygen durability.

  4. Effect of artificial aging on polymeric surge arresters and polymer insulators for electricity distribution networks

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Carlos A.; Coser, E. [Laboratorio de Materiais Polimericos, Departamento de Engenharia de Materiais, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil)], e-mail: ferreira.carlos@ufrgs.br; Angelini, Joceli M.G. [Departamento de Materiais Eletricos, CPqD, Campinas, SP (Brazil); Rossi, Jose A.D. [Materiais Alta Tensao, CPqD, Campinas, SP (Brazil); Martinez, Manuel L.B. [Departamento de Engenharia Eletrica, UNIFEI, Itajuba, MG (Brazil)

    2011-07-01

    A study was conducted to evaluate new and laboratory-aged samples of surge arresters and anchorage polymeric insulators, for 12 and 24 kV networks, which are used by the Rio Grande Energia (RGE). Power utility polymeric compounds were analyzed by Differential Scanning Calorimetry (DSC), Thermogravimetric Analysis (TG), Dynamic-Mechanic Analysis (DMA), Fourier Transformed Infrared Spectroscopy (FTIR) and Scanning Electronic Microscopy (SEM) to verify changes in the insulator properties due to degradation occurred during the experiments. The analyses were carried out before and after 6 months of aging in laboratory devices (weather meter, 120 deg C, salt spray, immersion in water). After the aging experiments, high-voltage electrical tests were also conducted: a radio interference voltage test and, simultaneously, the total and the internal leakage currents were measured to verify the surface degradation of the polymeric material used in the housing. The impulse current test was applied with current values close to 5, 10 and 30 k A, in order to force an internal degradation. Results showed that only surface degradation is detected at the polymer. The main properties of the parts were not affected by the aging. It confirms that polymer insulator and surge arrester are appropriate for use in electricity distribution networks. (author)

  5. Research on High Temperature Ceramic Insulation for Electrical Conductors

    Science.gov (United States)

    Kreidler, Eric R.; Bhallamudi, Vidya Praveen

    2001-01-01

    Three methods for applying ceramic coatings to wires were examined in depth and a fourth (chemical vapor deposition) was studied briefly. CVD coatings were not reported in the thesis because it was realized early in the study that the deposition rate of the coatings was too slow to be used in a commercial process. Of the methods reported in the thesis, slurry coating was the most promising. This method consists of slowly drawing a platinum wire through a thixotropic slurry of alumina in a vehicle composed of polyvinyl butyral, methyl ethyl ketone, and toluene. The coatings produced by this method were continuous and free of cracks after sintering. The sintered coatings crack when the wire is bent around sharp corners, but most of the coating remains in place and still provides electrical insulation between the wire and any metallic structure to which the wire may be attached. The coating thickness was 0.61 mm (16 micrometers). The electrical resistivity of the intact coating was 340 M-Ohm-cm at 800 C and 23 M-Ohm-cm at 1050 C. Therefore, these coatings more than meet the electrical requirements for use in turbine engines. Although adherence of the coating to the wire was generally excellent, a problem was noted in localized areas where the coating flaked off. Further work will be needed to obtain good coating adherence along the entire length of the wire. The next most promising coatings were made by electrophoretic deposition (EPD) of Al2O3 onto platinum wires, using mixtures of ethanol and acetone as the suspending liquid. These EPD coatings were made only on short lengths of wire because the coating is too fragile to allow spooling of the wire. The worst coatings were those made by electrophoretic deposition from aqueous suspensions. Continuous slurry coating of wire was achieved, but due to lack of suitable equipment, the wire had to be cut into short lengths for sintering.

  6. Heat transfer in electrical insulation of LHC cables cooled with superfluid helium

    CERN Document Server

    Meuris, C; Leroy, D; Szeless, Balázs

    1999-01-01

    The electrical insulation of the Large Hadron Collider (LHC) cables constitutes a thermal barrier between the conductor and the superfluid helium bath. This can prevent removal of the heat dissipated in the cable by the current rise in the dipoles or by the beam losses. The main experimental results, obtained with stacks of insulated conductors representing a piece of the actual coil, are given. The mock-ups vary only by the material composition and the structure of the electrical insulation. Analysis of the temperature distribution measured in the conductors as a function of the dissipated heat power makes it possible to determine the dominant heat transfer mode in each type of tested insulation and to classify these according to their permeability to superfluid helium. Thermal numerical modelling of the experimental mock-ups clarifies the heat transfer path in the complex structure of the insulation and enables calculation of values of the thermal quantities characteristic of each insulation. The results of...

  7. Electrical performance of distribution insulators with chlorella vulgaris growth on its surface

    Directory of Open Access Journals (Sweden)

    H. E. Rojas

    2015-11-01

    Full Text Available This paper presents a study about electrical performance of ceramic and polymeric insulators bio-contaminated with alga Chlorella vulgaris. The performed tests involve ANSI 55-2 and ANSI 52-1 ceramic insulators and ANSI DS-15 polymeric insulators, all of them used in distribution systems of Colombia. Biological contamination of insulators is realized using a controlled environment chamber that adjusts the temperature, humidity and light radiation. The laboratory tests include measurements of flashover voltages and leakage currents and they were performed to determine how insulators are affected by biological contamination. After a series of laboratory tests, it was concluded that the presence of Chlorella vulgaris on the contaminated ceramic insulators reduces the wet flashover voltage up to 12% and increases their leakage currents up to 80%. On the other hand, for polymeric insulators the effect of algae growth on flashover voltages was not to strong, although the leakage currents increase up to 60%.

  8. Electrical-Based Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers

    Directory of Open Access Journals (Sweden)

    Issouf Fofana

    2016-08-01

    Full Text Available The condition of the internal cellulosic paper and oil insulation are of concern for the performance of power transformers. Over the years, a number of methods have been developed to diagnose and monitor the degradation/aging of the transformer internal insulation system. Some of this degradation/aging can be assessed from electrical responses. Currently there are a variety of electrical-based diagnostic techniques available for insulation condition monitoring of power transformers. In most cases, the electrical signals being monitored are due to mechanical or electric changes caused by physical changes in resistivity, inductance or capacitance, moisture, contamination or aging by-products in the insulation. This paper presents a description of commonly used and modern electrical-based diagnostic techniques along with their interpretation schemes.

  9. Insulated Solar Electric Cooking – Tomorrow's healthy affordable stoves?

    Directory of Open Access Journals (Sweden)

    T. Watkins

    Full Text Available We present a cooking technology consisting of a solar panel directly connected to an electric heater inside of a well-insulated chamber. Assuming continued decrease in solar panel prices, we anticipate that in a few decades Solar Electric Cooking (SEC technologies will be the most common cooking technology for the poor. Appropriate use of insulation reduces the power demand making low-power Insulated Solar Electric Cooking (ISEC systems already cost competitive. We present a $100 prototype and preliminary results of two implementations in Uganda.

  10. Effect of pollutant gases on electrical insulators deterioration

    Directory of Open Access Journals (Sweden)

    Zamarad, A.

    2000-06-01

    Full Text Available In this work ceramic materials as electrical insulators have been exposed in laboratory-based chambers. Water contact angle and FTIR of the surface before and after pollutant exposures have been studied. The results indicated that the reaction between the policrete and the atmospheric pollutant produce some salts deposits, some hydrolysis over the resin surface, modifying water contact angle.

    En este trabajo se exponen en cámaras atmosféricas de laboratorio materiales cerámicos usados como aislantes eléctricos. Se realiza un estudio de la superficie expuesta a la degradación medioambiental a través del ángulo de contacto de una gota de agua y de las sales depositadas, determinándose éstas últimas por espectroscopia infrarroja. Los resultados revelan el depósito de varias sales sobre la superficie de la muestra, e hidrólisis sobre la superficie de la resina, modificando el ángulo de contacto.

  11. Ceramics Porcelain Based Electric Solid Insulator Using Local Raw Materials

    Directory of Open Access Journals (Sweden)

    Eva Indiani

    2009-08-01

    Full Text Available AbstractElectric solid insulator based on ceramics porcelain had been made by using local raw materials: 68% feldspar, 10% kaolinite and 22% quartz, and also added 0%, 5%, 10%, 15%, 20%, 25% cullet (From total mass. The forming process of the porcelain was conducted by milling the raw materials using ball mill and screened using 200 mesh screening. The samples were formed by using the dry-press method with the pressure of 50MPa, then the samples is sintered at temperature of 1000oC, 1050oC, 1100oC, 1150oC for 2 hours. The properties of the samples had been analyzed for their shrinkage, density, bending strength and resistivity. The result of the experiment showed that the optimum value was reached by ceramic which was added by 15% cullet and sintered at temperature of 1100oC. This ceramic had shrinkage of 9,70%, density of 2,44 g/cm3, bending strength of 86,73 MPa and the resistivity at 25oC is 2,32x108 Ωcm.

  12. Development of electrically insulating CaO coatings

    Energy Technology Data Exchange (ETDEWEB)

    Natesan, K.; Reed, C.B.; Uz, M.; Rink, D.L. [Argonne National Lab., IL (United States)

    1998-09-01

    A systematic study has been initiated to develop electrically insulating CaO coatings by vapor phase transport and by in-situ formation in a liquid Li environment. Several experiments were conducted in vapor transport studies with variations in process temperature, time, specimen location, specimen surface preparation, and pretreatment. Several of the coatings obtained by the method exhibited Ca concentration in the range of 60--95 wt.% on the surface. However, coating thickness has not been very uniform among several samples exposed in the same run or even within the same sample. The coatings developed in these early tests degraded after 24 h exposure to Li at 500 C. Additional experiments are underway to develop better-adhering and more dense coatings by this method. A program to develop in-situ CaO coatings in Li has been initiated, and the first set of capsule tests at 800 C in three different Li-Ca mixtures will be completed in early July. Specimens included in the run are bare V-4Cr-4Ti alloy, specimens with a grit-blasted surface and O-precharged in 99.999% Ar, polished specimens precharged in a 99.999% Ar and 5000 ppm O{sub 2}-N{sub 2} mixture, and prealuminized V-5Cr-5Ti alloy preoxidized in a 5000 ppm O{sub 2}-N{sub 2} mixture. Additional experiments at lower temperatures are planned.

  13. Characterization of dielectric properties of nanocellulose from wood and algae for electrical insulator applications.

    Science.gov (United States)

    Le Bras, David; Strømme, Maria; Mihranyan, Albert

    2015-05-07

    Cellulose is one of the oldest electrically insulating materials used in oil-filled high-power transformers and cables. However, reports on the dielectric properties of nanocellulose for electrical insulator applications are scarce. The aim of this study was to characterize the dielectric properties of two nanocellulose types from wood, viz., nanofibrillated cellulose (NFC), and algae, viz., Cladophora cellulose, for electrical insulator applications. The cellulose materials were characterized with X-ray diffraction, nitrogen gas and moisture sorption isotherms, helium pycnometry, mechanical testing, and dielectric spectroscopy at various relative humidities. The algae nanocellulose sample was more crystalline and had a lower moisture sorption capacity at low and moderate relative humidities, compared to NFC. On the other hand, it was much more porous, which resulted in lower strength and higher dielectric loss than for NFC. It is concluded that the solid-state properties of nanocellulose may have a substantial impact on the dielectric properties of electrical insulator applications.

  14. Insulation Resistance Monitoring Algorithm for Battery Pack in Electric Vehicle Based on Extended Kalman Filtering

    National Research Council Canada - National Science Library

    Chuanxue Song; Yulong Shao; Shixin Song; Silun Peng; Fang Zhou; Cheng Chang; Da Wang

    2017-01-01

    To improve the accuracy of insulation monitoring between the battery pack and chassis of electric vehicles, we established a serial battery pack model composed of first-order resistor-capacitor (RC...

  15. Study on the Microscopic Figures of Power Transformer Insulation Paper Under Electrical and Thermal Stresses

    Science.gov (United States)

    Liao, Rui-Jin; Tang, Chao; Yang, Li-Jun

    In this paper, Atomic Force Microscope (AFM) was used to observe the microscopic figure of aged insulation paper in order to analyze the microscopic ageing mechanism of power transformer insulation paper under electrical and thermal stresses. The results indicate that there are obvious concaves and convexes on the surface of aged insulation paper, and the paper samples are punctured because of chain scission and the flow of discharge current, which destroyed the compact cellulose chains structures and the diameter of punctures is about 0.5 nm. In addition, this paper analyzed the influence to the physical chemistry characteristics of insulation paper caused by partial discharge and paper ageing.

  16. Comparison of Dissolved Gases in Mineral and Vegetable Insulating Oils under Typical Electrical and Thermal Faults

    Directory of Open Access Journals (Sweden)

    Chenmeng Xiang

    2016-04-01

    Full Text Available Dissolved gas analysis (DGA is attracting greater and greater interest from researchers as a fault diagnostic tool for power transformers filled with vegetable insulating oils. This paper presents experimental results of dissolved gases in insulating oils under typical electrical and thermal faults in transformers. The tests covered three types of insulating oils, including two types of vegetable oil, which are camellia insulating oil, Envirotemp FR3, and a type of mineral insulating oil, to simulate thermal faults in oils from 90 °C to 800 °C and electrical faults including breakdown and partial discharges in oils. The experimental results reveal that the content and proportion of dissolved gases in different types of insulating oils under the same fault condition are different, especially under thermal faults due to the obvious differences of their chemical compositions. Four different classic diagnosis methods were applied: ratio method, graphic method, and Duval’s triangle and Duval’s pentagon method. These confirmed that the diagnosis methods developed for mineral oil were not fully appropriate for diagnosis of electrical and thermal faults in vegetable insulating oils and needs some modification. Therefore, some modification aiming at different types of vegetable oils based on Duval Triangle 3 were proposed in this paper and obtained a good diagnostic result. Furthermore, gas formation mechanisms of different types of vegetable insulating oils under thermal stress are interpreted by means of unimolecular pyrolysis simulation and reaction enthalpies calculation.

  17. Concepts for evaluation of sound insulation of dwellings

    DEFF Research Database (Denmark)

    Rasmussen, Birgit; Rindel, Jens Holger

    2005-01-01

    Legal sound insulation requirements have existed more than 50 years in some countries, and single-number quantities for evaluation of sound insulation have existed nearly as long time. However, the concepts have changed considerably over time from simple arithmetic averaging of frequency bands......¬ments and classification schemes revealed significant differences of concepts. The paper summarizes the history of concepts, the disadvantages of the present chaos and the benefits of consensus concerning concepts for airborne and impact sound insulation between dwellings and airborne sound insulation of facades...... with a trend towards light-weight constructions are contradictory and challenging. This calls for exchange of data and experience, implying a need for harmonized concepts, including use of spectrum adaptation terms. The paper will provide input for future discussions in EAA TC-RBA WG4: "Sound insulation...

  18. Using Expert Systems in Evaluation of the State of High Voltage Machine Insulation Systems

    Directory of Open Access Journals (Sweden)

    K. Záliš

    2000-01-01

    Full Text Available Expert systems are used for evaluating the actual state and future behavior of insulating systems of high voltage electrical machines and equipment. Several rule-based expert systems have been developed in cooperation with top diagnostic workplaces in the Czech Republic for this purpose. The IZOLEX expert system evaluates diagnostic measurement data from commonly used offline diagnostic methods for the diagnostic of high voltage insulation of rotating machines, non-rotating machines and insulating oils. The CVEX expert system evaluates the discharge activity on high voltage electrical machines and equipment by means of an off-line measurement. The CVEXON expert system is for evaluating the discharge activity by on-line measurement, and the ALTONEX expert system is the expert system for on-line monitoring of rotating machines. These developed expert systems are also used for educating students (in bachelor, master and post-graduate studies and in courses which are organized for practicing engineers and technicians and for specialists in the electrical power engineering branch. A complex project has recently been set up to evaluate the measurement of partial discharges. Two parallel expert systems for evaluating partial dischatge activity on high voltage electrical machines will work at the same time in this complex evaluating system.

  19. High Temperature Electrical Insulation Materials for Space Applications Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's future space science missions cannot be realized without the state of the art high temperature insulation materials of which higher working temperature, high...

  20. Electrical and structural R&D activities on high voltage dc solid insulator in vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Pilan, N., E-mail: nicola.pilan@igi.cnr.it [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Marcuzzi, D.; Rizzolo, A.; Grando, L.; Gambetta, G. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Rosa, S. Dalla [Umicore – Italbras S.p.A., Strada del Balsego, n.6, 36100 Vicenza (Italy); Kraemer, V.; Quirmbach, T. [FRIATEC Ceramics Division, Steinzeugstrasse 50, 68229 Mannheim (Germany); Chitarin, G. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Gobbo, R.; Pesavento, G. [DII, Università di Padova, v. Gradenigo 6/A, I-35131 Padova (Italy); De Lorenzi, A.; Lotto, L.; Rizzieri, R.; Fincato, M.; Romanato, L.; Trevisan, L.; Cervaro, V.; Franchin, L. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy)

    2015-10-15

    Highlights: • A thorough R&D activity on the MITICA post insulator prototypes is being carried out. • The design has been numerically verified considering both mechanical and electrical aspects. • Experimental validation has been started, with positive results in both involved fields. • Alternative design solutions thickness have been proposed and successfully tested. - Abstract: This paper describes the R&D work performed in support of the design of the alumina insulators for the MITICA Neutral Beam Injector. The ceramic insulators are critical elements, both from the structural and electrical point of view, of the 1 MV electrostatic accelerator of the MITICA injector, as they are required to sustain both the mechanical loads due to the cantilevered weight of the ion source and the high electric field between the accelerator grids. This paper presents the results of numerical simulations and experimental tests on prototypes that have been carried out to validate the insulator design under realistic operating conditions.

  1. Evaluating thermophysical properties of insulating materials

    Energy Technology Data Exchange (ETDEWEB)

    Yurchenko, V.G.; Antonova, V.V.; Grishchenko, T.G.

    1982-01-01

    A plan is described for automation of thermophysical experiment based on the IT-3 instrument. Results are presented from the experimental determination of the heat conductance coefficient of a number of rigid and elastic insulating materials used for heating heat tracks.

  2. Automatic extraction of insulators from 3D LiDAR data of an electrical substation

    Directory of Open Access Journals (Sweden)

    M. Arastounia

    2013-10-01

    Full Text Available A considerable percentage of power outages are caused by animals that come into contact with conductive elements of electrical substations. These can be prevented by insulating conductive electrical objects, for which a 3D as-built plan of the substation is crucial. This research aims to create such a 3D as-built plan using terrestrial LiDAR data while in this paper the aim is to extract insulators, which are key objects in electrical substations. This paper proposes a segmentation method based on a new approach of finding the principle direction of points’ distribution. This is done by forming and analysing the distribution matrix whose elements are the range of points in 9 different directions in 3D space. Comparison of the computational performance of our method with PCA (principal component analysis shows that our approach is 25% faster since it utilizes zero-order moments while PCA computes the first- and second-order moments, which is more time-consuming. A knowledge-based approach has been developed to automatically recognize points on insulators. The method utilizes known insulator properties such as diameter and the number and the spacing of their rings. The results achieved indicate that 24 out of 27 insulators could be recognized while the 3 un-recognized ones were highly occluded. Check point analysis was performed by manually cropping all points on insulators. The results of check point analysis show that the accuracy, precision and recall of insulator recognition are 98%, 86% and 81%, respectively. It is concluded that automatic object extraction from electrical substations using only LiDAR data is not only possible but also promising. Moreover, our developed approach to determine the directional distribution of points is computationally more efficient for segmentation of objects in electrical substations compared to PCA. Finally our knowledge-based method is promising to recognize points on electrical objects as it was

  3. Two-dimensional hexagonal boron nitride as lateral heat spreader in electrically insulating packaging

    Science.gov (United States)

    Bao, Jie; Edwards, Michael; Huang, Shirong; Zhang, Yong; Fu, Yifeng; Lu, Xiuzhen; Yuan, Zhichao; Jeppson, Kjell; Liu, Johan

    2016-07-01

    The need for electrically insulating materials with a high in-plane thermal conductivity for lateral heat spreading applications in electronic devices has intensified studies of layered hexagonal boron nitride (h-BN) films. Due to its physicochemical properties, h-BN can be utilised in power dissipating devices such as an electrically insulating heat spreader material for laterally redistributing the heat from hotspots caused by locally excessive heat flux densities. In this study, two types of boron nitride based heat spreader test structures have been assembled and evaluated for heat dissipation. The test structures separately utilised a few-layer h-BN film with and without graphene enhancement drop coated onto the hotspot test structure. The influence of the h-BN heat spreader films on the temperature distribution across the surface of the hotspot test structure was studied at a range of heat flux densities through the hotspot. It was found that the graphene-enhanced h-BN film reduced the hotspot temperature by about 8-10 °C at a 1000 W cm-2 heat flux density, a temperature decrease significantly larger than for h-BN film without graphene enhancement. Finite element simulations of the h-BN film predict that further improvements in heat spreading ability are possible if the thermal contact resistance between the film and test chip are minimised.

  4. Electric-field control of spin-orbit torque in a magnetically doped topological insulator

    OpenAIRE

    Fan, Yabin; Kou, Xufeng; Upadhyaya, Pramey; Shao, Qiming; Pan, Lei; Lang, Murong; Che, Xiaoyu; Tang, Jianshi; Montazeri, Mohammad; Murata, Koichi; Chang, Li-Te; Akyol, Mustafa; Yu, Guoqiang; Nie, Tianxiao; Wong, Kin L.

    2015-01-01

    Electric-field manipulation of magnetic order has proved of both fundamental and technological importance in spintronic devices. So far, electric-field control of ferromagnetism, magnetization and magnetic anisotropy has been explored in various magnetic materials, but the efficient electric-field control of spin-orbit torque (SOT) still remains elusive. Here, we report the effective electric-field control of a giant SOT in a Cr-doped topological insulator (TI) thin film using a top-gate FET ...

  5. Electrical Trees in a Composite Insulating System Consisted of Epoxy Resin and Mica: The Case of Multiple Mica Sheets For Machine Insulation

    Directory of Open Access Journals (Sweden)

    V. A. Kioussis

    2014-08-01

    Full Text Available Epoxy resin and mica sheets consist the essential insulation of rotating machine stator bars. Such an insulation, although very resistant to partial discharges, is subjected to considerable electrical stresses and consequently electrical trees may ensue. In this paper, an effort is made to simulate electrical tree propagation in multiple epoxy resin/mica sheets with the aid of Cellular Automata (CA. An attempt to compare the simulation results with experimental results is also made.

  6. Evaluation and comparison of insulation efficiency of three enhancer-blocking insulators in plants

    Science.gov (United States)

    Enhancer-promoter interactions potentially compromise the precise engineering of gene function and agronomically important traits in crops, which demands the adoption of strong, effective enhancer-blocking insulators to block such communication in a transgene construct. In this study, we evaluated ...

  7. A Study of the Properties of Electrical Insulation Oils and of the Components of Natural Oils

    Directory of Open Access Journals (Sweden)

    Milan Spohner

    2012-01-01

    Full Text Available This paper presents a study of the electrical and non-electrical properties of insulating oils. For the correct choice of an electrical insulation oil, it is necessary to know its density, dynamic viscosity, dielectric constant, loss number and conductivity, and the effects of various exposure factors. This paper deals with mathematical and physical principles needed for studying and making correct measurements of the dynamic viscosity, density and electrical properties of insulation oils. Rheological properties were measured using an A&D SV-10 vibratory viscometer, and analytical balance with density determination kit, which operates on the principle of Archimedes’ law. Dielectric properties were measured using a LCR meter Agilent 4980A with connected with the Agilent 16452A test fixture for dielectric liquids.

  8. Electrical resistance of individual defects at a topological insulator surface

    Science.gov (United States)

    Lüpke, Felix; Eschbach, Markus; Heider, Tristan; Lanius, Martin; Schüffelgen, Peter; Rosenbach, Daniel; von den Driesch, Nils; Cherepanov, Vasily; Mussler, Gregor; Plucinski, Lukasz; Grützmacher, Detlev; Schneider, Claus M.; Voigtländer, Bert

    2017-06-01

    Three-dimensional topological insulators host surface states with linear dispersion, which manifest as a Dirac cone. Nanoscale transport measurements provide direct access to the transport properties of the Dirac cone in real space and allow the detailed investigation of charge carrier scattering. Here we use scanning tunnelling potentiometry to analyse the resistance of different kinds of defects at the surface of a (Bi0.53Sb0.47)2Te3 topological insulator thin film. We find the largest localized voltage drop to be located at domain boundaries in the topological insulator film, with a resistivity about four times higher than that of a step edge. Furthermore, we resolve resistivity dipoles located around nanoscale voids in the sample surface. The influence of such defects on the resistance of the topological surface state is analysed by means of a resistor network model. The effect resulting from the voids is found to be small compared with the other defects.

  9. Relationship of Cure Temperature to Mechanical, Physical, and Dielectric Performance of PDMS Glass Composite for Electric Motor Insulation

    Science.gov (United States)

    Miller, Sandi G.; Becker, Kathleen; Williams, Tiffany S.; Scheiman, Daniel A.; McCorkle, Linda S.; Heimann, Paula J.; Ring, Andrew; Woodworth, Andrew

    2017-01-01

    Achieving NASAs aggressive fuel burn and emission reduction for N-plus-3 aircraft will require hybrid electric propulsion system in which electric motors driven by either power generated from turbine or energy storage system will power the fan for propulsion. Motors designed for hybrid electric aircraft are expected to operate at medium to high voltages over long durations in a high altitude service environment. Such conditions have driven research toward the development of wire insulation with improved mechanical strength, thermal stability and increased breakdown voltage. The silicone class of materials has been considered for electric wire insulation due to its inherent thermal stability, dielectric strength and mechanical integrity. This paper evaluates the dependence of these properties on the cure conditions of a polydimethyl-siloxane (PDMS) elastomer; where both cure temperature and base-to-catalyst ratio were varied. The PDMS elastomer was evaluated as a bulk material and an impregnation matrix within a lightweight glass veil support. The E-glass support was selected for mechanical stiffness and dielectric strength. This work has shown a correlation between cure conditions and material physical properties. Tensile strength increased with cure temperature whereas breakdown voltage tended to be independent of process variations. The results will be used to direct material formulation based on specific insulation requirements.

  10. Insulation Resistance Monitoring Algorithm for Battery Pack in Electric Vehicle Based on Extended Kalman Filtering

    OpenAIRE

    Chuanxue Song; Yulong Shao; Shixin Song; Silun Peng; Fang Zhou; Cheng Chang; Da Wang

    2017-01-01

    To improve the accuracy of insulation monitoring between the battery pack and chassis of electric vehicles, we established a serial battery pack model composed of first-order resistor-capacitor (RC) circuit battery cells. We then designed a low-voltage, low-frequency insulation monitoring model based on this serial battery pack model. An extended Kalman filter (EKF) was designed for this non-linear system to filter the measured results, thus mitigating the influence of noise. Experimental and...

  11. Insulation Resistance Monitoring Algorithm for Battery Pack in Electric Vehicle Based on Extended Kalman Filtering

    Directory of Open Access Journals (Sweden)

    Chuanxue Song

    2017-05-01

    Full Text Available To improve the accuracy of insulation monitoring between the battery pack and chassis of electric vehicles, we established a serial battery pack model composed of first-order resistor-capacitor (RC circuit battery cells. We then designed a low-voltage, low-frequency insulation monitoring model based on this serial battery pack model. An extended Kalman filter (EKF was designed for this non-linear system to filter the measured results, thus mitigating the influence of noise. Experimental and simulation results show that the proposed monitoring model and extended Kalman filtering algorithm for insulation resistance monitoring present satisfactory estimation accuracy and robustness.

  12. Mathematical Model of Lifetime Duration at Insulation of Electrical Machines

    Directory of Open Access Journals (Sweden)

    Mihaela Răduca

    2009-10-01

    Full Text Available Abstract. This paper present a mathematical model of lifetime duration at hydro generator stator winding insulation when at hydro generator can be appear the damage regimes. The estimation to make by take of the programming and non-programming revisions, through the introduction and correlation of the new defined notions.

  13. Investigation of electrical characteristics of no-insulation coil wound with surface-processed HTS tape

    Science.gov (United States)

    Jeon, Haeryong; Lee, Woo Seung; Kim, Jinsub; Baek, Geonwoo; Jeon, Sangsu; Yoon, Yong Soo; Ko, Tae Kuk

    2017-08-01

    This paper deals with the electrical characteristics of no-insulation coil wound with surface-processed HTS tape. The bypassing current path through turn-to-turn contacts within a coil is formed in the no-insulation coil, and this bypassing current path determines two characteristics: 1) self-protection and 2) charge-discharge delay. The amplitude of bypassing current is determined by contact resistance between the turn-to-turn contacts of the no-insulation coil. The surface roughness of the HTS tape is one of the parameters to change the contact resistance. The HTS tapes were processed to roughen by bead blast and abrasive paper, and the no-insulation coil is fabricated using processed HTS tape. We have studied the charge-discharge delay and self-protecting characteristic of each no-insulation coil by 1) sudden discharge tests and 2) overcurrent tests. The FEM simulations of contact resistance of no-insulation coil were carried out. The contact surface resistance of a case processed by abrasive paper has almost three times larger than that of reference no-insulation coil, and a case processed by bead blast presents almost same contact surface resistance with reference no-insulation coil.

  14. Studies on electrical cable insulation for nuclear applications

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B.S.; Soo, P.; MacKenzie, D.R. [Brookhaven National Lab., Upton, NY (USA); Blackburn, P. [Beloit Junior-Senior High School, KS (USA)

    1989-12-01

    Two new polyethylene cable insulations have been formulated for nuclear applications, and have been tested under gamma radiation. Both insulations are based on low density polyethylene, one with PbO and the other with Sb{sub 2}O{sub 3} as additives. The test results show that the concept of using inorganic anti-oxidants to retard radiation initiated oxidation is viable, and PbO is more effective than Sb{sub 2}O{sub 3} in slowing down radiation initiated oxidation (RIO). Also, radiation degradation data for polyethylene and polyvinyl chloride at 60{degrees}C have been generated, which will be used to understand radiation initiated oxidation process on these materials combined with the 25{degrees}C data that will be generated in the future. 14 refs., 41 figs., 3 tabs.

  15. Effect on superhydrophobic surfaces on electrical porcelain insulator, improved technique at polluted areas for longer life and reliability

    OpenAIRE

    Isaac Ramalla; Rajeev K Gupta; Kamal Bansal

    2015-01-01

    This paper proposes a novel technique to enhance the stability of high-voltage insulators, which are affected due to the presence of dust, contamination, electrical stresses in a high moisture content environment. These result in puncture of insulators and heavy loss due to power outages in the transmission lines. To extend its stability, powdered coating is done on the insulators which have insulation property and super hydrophobicity. In this paper, the authors were inspired by the ‘lotus e...

  16. Transfer-Free Electrical Insulation of Epitaxial Graphene from its Metal Substrate

    DEFF Research Database (Denmark)

    Lizzit, Silvano; Larciprete, Rosanna; Lacovig, Paolo

    2012-01-01

    High-quality, large-area epitaxial graphene can be grown on metal surfaces, but its transport properties cannot be exploited because the electrical conduction is dominated by the substrate. Here we insulate epitaxial graphene on Ru(0001) by a stepwise intercalation of silicon and oxygen......, and the eventual formation of a SiO2 layer between the graphene and the metal. We follow the reaction steps by X-ray photoemission spectroscopy and demonstrate the electrical insulation using a nanoscale multipoint probe technique....

  17. Electrical Performance of Distribution Insulators with Chlorella vulgaris Growth on its Surface

    Directory of Open Access Journals (Sweden)

    Herbert Enrique Rojas Cubides

    2015-06-01

    Full Text Available This paper presents a study about electrical performance of ceramic and polymeric insulators bio-contaminated with alga Chlorella vulgaris. The performed tests involve ANSI 55-2 and ANSI 52-1 ceramic insulators and ANSI DS-15 polymeric insulators, all of them used in distribution systems of Colombia. Biological contamination of insulators is realized using a controlled environment chamber that adjusts the temperature, humidity and light radiation. The laboratory tests include measurements of flashover voltages and leakage currents and they were performed to determine how insulators are affected by biological contamination. After a series of laboratory tests, it was concluded that the presence of Chlorella vulgaris on the contaminated ceramic insulators reduces the wet flashover voltage up to 12% and increases their leakage currents up to 80%. On the other hand, for polymeric insulators the effect of algae growth on flashover voltages was not to strong, although the leakage currents increase up to 60%.

  18. Electrically induced insulator to metal transition in epitaxial SmNiO{sub 3} thin films

    Energy Technology Data Exchange (ETDEWEB)

    Shukla, Nikhil, E-mail: nss152@psu.edu; Dasgupta, Sandeepan; Datta, Suman [Department of Electrical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802 (United States); Joshi, Toyanath; Borisov, Pavel; Lederman, David [Department of Physics and Astronomy, West Virginia University, Morgantown, West Virginia 26506-6315 (United States)

    2014-07-07

    We report on the electrically induced insulator to metal transition (IMT) in SmNiO{sub 3} thin films grown on (001) LaAlO{sub 3} by pulsed laser deposition. The behavior of the resistivity as a function of temperature suggests that the primary transport mechanism in the SmNiO{sub 3} insulating state is dominated by Efros-Shklovskii variable range hopping (ES-VRH). Additionally, the magnetic transition in the insulating state of SmNiO{sub 3} modifies the characteristics of the ES-VRH transport. Systematic DC and pulsed current-voltage measurements indicate that current-induced joule heating is the fundamental mechanism driving the electrically induced IMT in SmNiO{sub 3}. These transport properties are explained in context of the IMT in SmNiO{sub 3} being related to the strong electron-lattice coupling.

  19. Doping Effect of Graphene Nanoplatelets on Electrical Insulation Properties of Polyethylene: From Macroscopic to Molecular Scale

    Directory of Open Access Journals (Sweden)

    Ziang Jing

    2016-08-01

    Full Text Available The doping effect of graphene nanoplatelets (GNPs on electrical insulation properties of polyethylene (PE was studied by combining experimental and theoretical methods. The electric conduction properties and trap characteristics were tested for pure PE and PE/GNPs composites by using a direct measurement method and a thermal stimulated current (TSC method. It was found that doping smaller GNPs is more beneficial to decrease the conductivity of PE/GNPs. The PE/GNPs composite with smaller size GNPs mainly introduces deep energy traps, while with increasing GNPs size, besides deep energy traps, shallow energy traps are also introduced. These results were also confirmed by density functional theory (DFT and the non-equilibrium Green’s function (NEGF method calculations. Therefore, doping small size GNPs is favorable for trapping charge carriers and enhancing insulation ability, which is suggested as an effective strategy in exploring powerful insulation materials.

  20. Doping Effect of Graphene Nanoplatelets on Electrical Insulation Properties of Polyethylene: From Macroscopic to Molecular Scale.

    Science.gov (United States)

    Jing, Ziang; Li, Changming; Zhao, Hong; Zhang, Guiling; Han, Baozhong

    2016-08-10

    The doping effect of graphene nanoplatelets (GNPs) on electrical insulation properties of polyethylene (PE) was studied by combining experimental and theoretical methods. The electric conduction properties and trap characteristics were tested for pure PE and PE/GNPs composites by using a direct measurement method and a thermal stimulated current (TSC) method. It was found that doping smaller GNPs is more beneficial to decrease the conductivity of PE/GNPs. The PE/GNPs composite with smaller size GNPs mainly introduces deep energy traps, while with increasing GNPs size, besides deep energy traps, shallow energy traps are also introduced. These results were also confirmed by density functional theory (DFT) and the non-equilibrium Green's function (NEGF) method calculations. Therefore, doping small size GNPs is favorable for trapping charge carriers and enhancing insulation ability, which is suggested as an effective strategy in exploring powerful insulation materials.

  1. A concept for the intrinsic dielectric strength of electrical insulation materials

    Science.gov (United States)

    Cuddihy, E. F.

    1985-04-01

    A concept is described for a possible definition of the intrinsic dielectric strength of insulating materials, which can be considered as a fundamental material property similar to other material properties, such as Young's modulus, index of refraction, and expansion coefficients. The events leading to the recognition of this property are reported, and the property is defined. This intrinsic dielectric strength concept should facilitate interpretation of results from accelerated and/or natural aging programs intended to predict electrical insulation service life of encapsulants in photovoltaic modules. As a practical application, this new concept enabled a possible explanation of the cause of failures in buried high-voltage cable with polyethylene insulation, and a possible explanation of the causes of electrical trees in polyethylene; these also are described.

  2. The effects of fillers on polyurethane resin-based electrical insulators

    Directory of Open Access Journals (Sweden)

    Altafim Ruy Alberto Corrêa

    2003-01-01

    Full Text Available The increasingly widespread use of polymeric insulators in vehicle distributors and transmission systems has led to an ongoing quest for quality and low costs. This quest has, in turn, resulted in improved performance and cost benefits, brought about by the use of new polymeric and composite resins. Occasionally, however, while some properties are improved, others may show a loss of optimal performance. Therefore, to understand the behavior of fillers, such as carbon black, silica and mica added to castor oil-derived polyurethane resins, several thermal, mechanical and electrical tests were conducted on samples and insulators produced specifically for this purpose, using these new materials. The results of these tests clearly demonstrated that this type of resin and its composites can be used to manufacture indoor electrical insulators and that the fillers analyzed in this study improve or maintain the characteristics of the pure resins.

  3. EXPERIMENTAL STUDY FOR PERFORMANCE EVALUATION OF INSULATOR USING VARIOUS COATING MATERIALS UNDER DIFFERENT ATMOSPHERIC CONDITIONS

    OpenAIRE

    Akshay Singh Thakur; Prof. Arun Pachori

    2017-01-01

    In this study, we have an insulator is subjected to high voltage under various atmospheric condition. Without porcelain and asbestos coatings to judge the performance and with porcelain and asbestos coatings to judge the performance of electrical insulation materials, upto 44 KV during various atmospheric condition. And for porcelain insulating material, upto 41 KV.

  4. Carbon nanotubes integrated in electrically insulated channels for lab-on-a-chip applications

    DEFF Research Database (Denmark)

    Mogensen, Klaus Bo; Gangloff, L.; Bøggild, Peter

    2009-01-01

    A fabrication process for monolithic integration of vertically aligned carbon nanotubes in electrically insulated microfluidic channels is presented. A 150 nm thick amorphous silicon layer could be used both for anodic bonding of a glass lid to hermetically seal the microfluidic glass channels...

  5. Modeling, Fabrication, and Electrical Testing of Metal-Insulator-Metal Diode

    Science.gov (United States)

    2011-12-01

    Horizon: Optical Rectenna Solar Cell; NREL/SR-520-33263; NREL, August 2011. [4] Simmons, J. G. Generalized Formula for the Electric Tunnel Effect between...K. Design and Develop- ment of Batch Fabricatable Metal-Insulator-Metal Diode and Microstrip Slot Antenna as Rectenna Elements. Sensors and

  6. Electrical treeing in ceramic-based insulating materials (Ba TiO3 ...

    African Journals Online (AJOL)

    Electrical treeing in ceramic-based insulating materials (Ba TiO3 – SiO2). ... It was observed that the tree-like structures were of two types and that the initiation could have been due to partial discharges that arose from microcracks, pores and other similar defects. This equally shows that the mechanism of the initiation of an ...

  7. An Explosively Actuated Electrical Switch Using Kapton Insulation

    Science.gov (United States)

    1993-03-01

    would also like to thank our colleagues who made valuable contributions to the experimental effort: Robert Hay, Nathaniel Snowden , and Bernard... Snowden . The authors are grateful to J. Forbes who made many valuable comments on this manuscript. Approved by: KURT F. MUELLER, Head Warheads and...field; see Figure l-l(B). 1-1 NSWCDD/TR-92/124 Electrodes Shock Front Electric Field Kaptori Film Electrodes, Shock Front El Electric

  8. ESTIMATION OF INDUCED CURRENTS IN THE SHIELDS OF ELECTRICAL POWER CABLES WITH XLPE INSULATION

    Directory of Open Access Journals (Sweden)

    I. V. Oleksyuk

    2015-01-01

    Full Text Available Electrical power cables with Cross-Linked Polyethylene Insulation (XLPE-insulation are currently utilized in projects of the electric-power supply systems of modern facilities. However, the higher costs, the incomplete design, installation and maintenance normativetechnical basis as well as certain constructional features of the XLPE-insulated cable lines hinder their large-scale implementation.The cables with XLPE insulation are mostly produced in a single-conductor core version being provided with a composite copper shield whose cross-section may vary while the electric conductor cross-section remains uniform. Earthing the cable shields on both sides causes the flow of electricity in them. The course of operational service of the XLPE-insulated cable lines revealed the following fact – the currents induced in the cable shields can run up to the levels commeasurable with those in the conductor-cores themselves. That, in its turn, leads to electrical safety-level reduction, cable lines failure, and economic losses. The currents induced in the shields may occur both in symmetric (normal and emergency and asymmetric operating modes of the power grid with values of the induced currents reaching 80 % of the conducting core currents. Many factors affect the level of the current induced in the shield: the midpoint conductor modes, the values of the core longitudinal currents in the normal and emergency operating modes, failure mode, the cross-section area of the shield, the cables mutual disposition, and the distance between them.The paper claims experimental existence conformation of the cable-shield current induced by that in the conductor-core and demonstrates its measured value. The author establishes that induction of dangerous currents in the cable shields demands elaboration of measures on reducing their level.

  9. Experimental evaluation of gas filled plenum (GFP) insulation for ducts

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; Guillot, Cyril

    2003-01-26

    Forced-air heating and cooling system ducts are often located outside conditioned space in US houses. For these systems to perform efficiently it is important that these ducts be well insulated. Common practice is to use a glass fiber wrap around the ducts--either field applied or more commonly, integrated into a flexible duct. Most duct insulation has an R-value of 4.2, with R6 and R8 ducts also occasionally used. With glass fiber insulation being about R4 per inch (RSI 0.28/cm), this adds 2 to 4 inches (50 to 100 mm) to the duct diameter. Some building codes are now requiring these higher insulation levels, for example, the EPA requires the use of R6 ducts, and International Energy Conservation Code (BOCA 2003) requires R8 ducts. The difficulty with adding insulation to ducts is the increase in diameter of the ducts that makes them expensive to transport because they take up a large volume and are difficult to install in the confined spaces available for ducts in houses. The objective of this study was to evaluate Gas Filled Plenum (GFP) technology as an alternative duct insulation. GFP ducts have the potential to provide greater insulation levels than existing ducts (for a given thickness of insulation or size of duct) and provide cost savings in transportation. These transportation cost savings are based on the idea of shipping the GFP ducts empty and inflating them on-site. To evaluate this technology for ducts we constructed a prototype duct and determined both its flow and heat transfer resistance in LBNL's duct testing laboratories. The GFP technology works by encapsulating a gas (usually air--but other noble gases such as Argon or Krypton can provide significant increases in thermal resistance with increased cost) in a metalized film jacket. A honeycomb structure is used to keep individual gas pockets small to minimize convection heat transfer. A metallic finish (usually aluminum) minimizes radiation heat transfer between the surfaces.

  10. Experimental evaluation of gas filled plenum (GFP) insulation for ducts

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; Guillot, Cyril

    2003-01-26

    Forced-air heating and cooling system ducts are often located outside conditioned space in US houses. For these systems to perform efficiently it is important that these ducts be well insulated. Common practice is to use a glass fiber wrap around the ducts--either field applied or more commonly, integrated into a flexible duct. Most duct insulation has an R-value of 4.2, with R6 and R8 ducts also occasionally used. With glass fiber insulation being about R4 per inch (RSI 0.28/cm), this adds 2 to 4 inches (50 to 100 mm) to the duct diameter. Some building codes are now requiring these higher insulation levels, for example, the EPA requires the use of R6 ducts (for Energy Star ducts), and International Energy Conservation Code (BOCA 2003) requires R8 ducts. The difficulty with adding insulation to ducts is the increase in diameter of the ducts that makes them expensive to transport because they take up a large volume and are difficult to install in the confined spaces available for ducts in houses. The objective of this study was to evaluate Gas Filled Plenum (GFP) technology as an alternative duct insulation. GFP ducts have the potential to provide greater insulation levels than existing ducts (for a given thickness of insulation or size of duct) and provide cost savings in transportation. These transportation cost savings are based on the idea of shipping the GFP ducts empty and inflating them on-site. To evaluate this technology for ducts we constructed a prototype duct and determined both its flow and heat transfer resistance in LBNL's duct testing laboratories. The GFP technology works by encapsulating a gas (usually air--but other noble gases such as Argon or Krypton can provide significant increases in thermal resistance with increased cost) in a metalized film jacket. A honeycomb structure is used to keep individual gas pockets small to minimize convection heat transfer. A metallic finish (usually aluminum) minimizes radiation heat transfer between the

  11. Epoxy/α-alumina nanocomposite with high electrical insulation performance

    Directory of Open Access Journals (Sweden)

    Yun Chen

    2017-10-01

    Full Text Available An experimental study was conducted to improve the electrical insulation of epoxy resin. The effects of boehmite, γ-alumina and α-alumina nanoparticles on the volume resistivity, dielectric strength and glass transition temperature of epoxy nanocomposites were investigated. The results showed that α-alumina nanoparticles displayed obvious advantages in enhancing electrical insulation performance of epoxy nanocomposites, compared to boehmite and γ-alumina nanoparticles. The direct current volume resistivity and breakdown strength of epoxy nanocomposite with 2.0 wt% α-alumina nanoparticles was improved to 2.2 × 1018 Ω cm and 76.1 kV mm−1 respectively. And these improved values of electrical insulation properties are much higher than these of epoxy nanocomposites reported in previous studies. The main reason of these improvements may be that the epoxy/α-alumina interaction zone was enhanced by crosslink. Keywords: Nanocomposite, Epoxy resin, Insulation, α-alumina

  12. Electrical Insulation Of Carbon Nanotube Separation Columns For Microchip Electrochromatography

    DEFF Research Database (Denmark)

    Mogensen, Klaus Bo; Chen, Miaoxiang Max; Mølhave, Kristian

    2011-01-01

    Carbon nanotubes (CNT) have been grown in microfluidic glass channels for chemical analysis based on electrokinetic separations. A limitation of CNTs for this type of application is their high conductivity, which prevent them from being used for electroosmotic pumping with electrical field...

  13. Polarizing Oxygen Vacancies in Insulating Metal Oxides under a High Electric Field

    Science.gov (United States)

    Youssef, Mostafa; Van Vliet, Krystyn J.; Yildiz, Bilge

    2017-09-01

    We demonstrate a thermodynamic formulation to quantify defect formation energetics in an insulator under a high electric field. As a model system, we analyzed neutral oxygen vacancies (color centers) in alkaline-earth-metal binary oxides using density functional theory, Berry phase calculations, and maximally localized Wannier functions. The work of polarization lowers the field-dependent electric Gibbs energy of formation of this defect. This is attributed mainly to the ease of polarizing the two electrons trapped in the vacant site, and secondarily to the defect induced reduction in bond stiffness and softening of phonon modes. The formulation and analysis have implications for understanding the behavior of insulating oxides in electronic, magnetic, catalytic, and electrocaloric devices under a high electric field.

  14. Remarkably improved electrical insulating performances of lightweight polypropylene nanocomposites with fullerene

    Science.gov (United States)

    Dang, Bin; Hu, Jun; Zhou, Yao; He, Jinliang

    2017-11-01

    A polypropylene/fullerene nanocomposite was fabricated via solution processing with good dispersion of the fullerene nanoparticles. It was observed that a small amount of fullerene (~1 wt. ‰) can significantly improve the direct current (DC) electrical insulation performance (i.e. improved space charge distribution, greater DC dielectric breakdown strength, and larger DC volume resistivity) of polypropylene. Thermally stimulated depolarization current tests indicate that fullerene doping remarkably increases the deep trap density of pure polypropylene. The mechanisms by which the electrical properties of the polypropylene nanocomposites were improved are the introduction of deep traps and the high electron affinity of fullerene. The deep traps result from the interfaces between polypropylene and fullerene. This work provides a potential method to tailor lightweight nanodielectric materials with excellent electrical insulating performances.

  15. Insulator-metal transitions induced by electric field and photoirradiation in organic Mott insulator deuterated κ-(BEDT-TTF)2Cu[N(CN)2]Br.

    Science.gov (United States)

    Sabeth, Farzana; Iimori, Toshifumi; Ohta, Nobuhiro

    2012-04-25

    The Mott insulator-metal transition induced by an external stimulus such as electric field, pressure, chemical doping, or photoirradiation has received considerable attention because of the potential use in new optoelectronic functional devices. Here we report an abrupt Mott insulator-metal transition observed as a current jump in a molecular-based Mott insulator, namely, deuterated κ-(BEDT-TTF)(2)Cu[N(CN)(2)]Br, where BEDT-TTF = bis(ethylenedithio)tetrathiafulvalene, upon application of a pulsed voltage of certain magnitude (threshold voltage). Furthermore, the threshold voltage needed for the transition is shown to be reduced by photoirradiation. Thus, the Mott insulator-metal transition can be controlled by a combination of an external electric field and photoirradiation.

  16. Thermal paint production: the techno-economic evaluation of muscovite as insulating additive.

    Directory of Open Access Journals (Sweden)

    Gabriela Fernandes Ribas

    2016-09-01

    Full Text Available Muscovite is known by its thermal and electrical insulating properties. Based on this, it was hypothesized that its addition on paints should increase the thermal resistance. The use of muscovite as mineral insulating is pointed out as advantageous due to its low cost compared to other materials used for this purpose, such as the ceramic microsphere. The use of a low cost material could open the access to the medium and low income families, implying two aspects: the life quality increase by thermal comfort and the increase of energy saving. Thus, this part of the population could open a new market to thermal paints. Aiming to contribute to this issue, this work evaluated the thermal insulation performance of commercial paints containing muscovite additions and determined the economic evaluation for its industrial production. The thermal paint was formulated by adding 10%, 20% and 40% of muscovite to the commercial paint. This was applied on steel reinforced mortar boards. Thermal insulation tests were carried out in bench scale using an adapted box. The economic evaluation of the industrial production of muscovite-based thermal paint was conducted, considering the Brazilian economic market in this activity. The results showed its ability as an insulating agent due to a reduction of 0.667 °C/mm board by the addition of 40% muscovite. The economic analysis also demonstrated the feasibility of the thermal paint industrial production. The payback is favorable to 5 years when compared to the Selic short-term lending rate, with 21.53% of internal rate return and a net present value of US$ 15,085.76.

  17. Cooling of electrically insulated high voltage electrodes down to 30 mK

    CERN Document Server

    Eisel, T; Burghart, G; Feigl, S; Haug, F; Koettig, T

    2011-01-01

    AEgIS [1] is an antimatter experiment, using high voltage electrodes at 100 mK. In this work two possible principles to cool these electrodes with a dilution refrigerator are described: the Rod and the Sandwich. The metallic Rod is electrically insulated by a ceramic and connects a single electrode directly with a heat exchanger placed in the mixing chamber. The Sandwich consists of an elec-trically insulating sapphire plate, at both sides covered with indium. The total thermal resistivities of the Rod and of different Sandwich samples are measured between (30 and 130) mK. The lowest resistivity of the Sandwich is achieved with indium vapour deposited on polished sapphire (26 cm2K4/W at 30 mK). The resistivity of the Rod is significantly lower (0.5 cm2K4/W at 30 mK).

  18. Electric-field-induced antiferromagnetic resonance in antiferromagnetic insulators with spin-orbit coupling

    Directory of Open Access Journals (Sweden)

    Akihiko Sekine

    2017-05-01

    Full Text Available We study theoretically spin dynamics in three-dimensional antiferromagnetic insulators with spin-orbit coupling. We focus on the antiferromagnetic insulators whose low-energy effective model possesses a topological term called the θ term. By solving the Landau-Lifshitz-Gilbert equation in the presence of the θ term, we show that the antiferromagnetic resonance can be realized by ac electric fields along with static magnetic fields. The antiferromagnetic resonance can be detected via the spin pumping from the Néel field and net magnetization. We calculate both contributions to the pumped spin current, and find that the magnitude of the ac electric field to cause the resonance state is very small (∼ 1 V/m. This indicates that spin currents can be generated efficiently. The mechanism of the antiferromagnetic resonance in this study is understood as the inverse process of the dynamical chiral magnetic effect.

  19. THE INSULATION PROBLEMS ON PORCELAIN INSULATORS

    Directory of Open Access Journals (Sweden)

    Engin ÇETİN

    2005-02-01

    Full Text Available Porcelain insulators used on electrical institutions are important materials to provide system reliability and material insulation. Specification of raw materials of insulators and environmental factors affect insulator strength and operation. In this study, environmental factors and materials used on porcelain insulator manufacturing are examined and also their influence on system reliability and insulation are investigated.

  20. THE INSULATION PROBLEMS ON PORCELAIN INSULATORS

    OpenAIRE

    Engin ÇETİN; N. Lerzan ÖZER; ÇETİN, Meriç

    2005-01-01

    Porcelain insulators used on electrical institutions are important materials to provide system reliability and material insulation. Specification of raw materials of insulators and environmental factors affect insulator strength and operation. In this study, environmental factors and materials used on porcelain insulator manufacturing are examined and also their influence on system reliability and insulation are investigated.

  1. Experimental study on the effects of AC electric fields on flame spreading over polyethylene-insulated electric-wire

    KAUST Repository

    Jin, Young Kyu

    2010-11-01

    In this present study, we experimentally investigated the effects of electric fields on the characteristics of flames spreading over electric-wires with AC fields. The dependence of the rate at which a flame spreads over polyethylene-insulated wires on the frequency and amplitude of the applied AC electric field was examined. The spreading of the flame can be categorized into linear spreading and non-linearly accelerated spreading of flame. This categorization is based on the axial distribution of the field strength of the applied electric field. The rate at which the flame spreads is highly dependent on the inclined direction of the wire fire. It could be possible to explain the spreading of the flame on the basis of thermal balance. © 2010 The Korean Society of Mechanical Engineers.

  2. Methyltrimethoxysilane-insulated piezoelectric microcantilevers for direct, all-electrical biodetection in buffered aqueous solutions

    Science.gov (United States)

    Capobianco, Joseph A.; Shih, Wan Y.; Shih, Wei-Heng

    2006-12-01

    We have examined coating (PbMg1/3Nb2/3O3)0.63-(PbTiO3)0.37 (PMN-PT)/tin piezoelectric microcantilever sensors (PEMSs) with a thin methyltrimethoxysilane (MTMS) by a simple solution method to electrically insulate the PEMS for biodetection in phosphate buffered saline (PBS) solutions. The PMN-PT/tin PEMSs were constructed using PMN-PT freestanding films that exhibited an electric-field-enhanced giant piezoelectric coefficient. The insulation procedure involved spin coatings of MTMS followed by cross-linking in water, which yielded a coating layer of about 10nm in thickness on the tin side of the PEMS. We showed that the MTMS-insulated PMN-PT/tin PEMSs were capable of electrical self-excitation and self-sensing with a stable resonance spectrum exhibiting a quality factor of Q =50 when submerged in 0.1M PBS solution. Direct, all-electrical, in situ detection of Escherichia coli O157:H7 at various concentrations was demonstrated at a flow rate of 0.5ml/min. A MTMS-insulated PMN-PT/tin PEMS 725μm long consisting of a 22-μm-thick PMN-PT layer and a 6-μm-thick tin layer exhibited a mass detection sensitivity Δm /Δf=-3±2×10-12g/Hz and a concentration sensitivity of better than 100cells/ml in less than 1ml of liquid.

  3. Methods for the improvement of electrical insulation in vacuum in the presence of transverse magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Hara, Masanori; Suehiro, Junya; Shigematsu, Hidetaka; Yano, Shinsuke (Kyushu Univ., Faculty of Engineering, Fukuoka, (Japan))

    1989-09-20

    When a transverse magnetic field is applied to an insulating system in vacuum, its dielectric strength deteriorates considerably and this breaking characteristic is considered to be caused by generation of impact ionization between the atoms of residual gas and electrons due to the cycloid movements of the latter. In this study, taking the above breaking mechanism into consideration, proposed were methods using a spiral spacer and an electric field control electrode as the methods of improving dielectric strength in vacuum of the cryogenic equipment generating such a strong magnetic field as superconducting magnet, etc.. Concerning the former method in case when a spiral pitch is infinitive and the latter method in case when a grounding electrode is installed in the neighborhood of the inside electrode, the respective effectiveness was demonstrated by experiments. In other words, with regard to the coaxial cylindrical electrode system, in case when no method of improving electrical insulation was applied, the breaking voltage decreased from about 20kV to about 1kV as the transverse magnetic field was made stronger, but in case when a spacer was used, the decline of electrical insulation could be suppressed within several kV up to the magnetic field of 4.65T and the magnetic field at which the decline of the breaking voltage started was increased three times by using a control electrode. 7 refs., 14 figs.

  4. Aging performance evaluation of vacuum insulation panel (VIP

    Directory of Open Access Journals (Sweden)

    Jin-Hee Kim

    2017-12-01

    Full Text Available Energy efficiency solutions are being pursued as a sustainable approach to reducing energy consumption and related gas emissions across various sectors of the economy. Vacuum Insulation Panel (VIP is an energy efficient advanced insulation system that facilitates slim but high-performance insulation, based on a porous core material evacuated and encapsulated in a barrier envelope. Although VIP has been on the market for decades now, it wasn’t until recently that efforts have been initiated to propose and adopt a global standard on characterization and testing. One of the issues regarding VIP is its durability and aging due to pressure and moisture dependent increase of the initial low thermal conductivity with time; more so in building applications. In this paper, the aging performance of commercially available VIP was investigated experimentally; thermal conductivity was tested in accordance with ISO 8302 standard (guarded hot plate method and their long-term performance was analyzed based on a non-linear pressure-humidity dependent equation based on IEA/EBC Annex 39, with the aim of evaluating durability of VIP. The center-of-panel thermal conductivity after 25 years based on initial 90% fractile with a confidence level of 90% for the thermal conductivity (λ90/90 ranged from 7.3–8.2 mW/(m K for silica core VIP. Significant differences between manufacturer-provided data and measurements of thermal conductivity and internal pressure were observed.

  5. Thermal Performance Evaluation of Walls with Gas Filled Panel Insulation

    Energy Technology Data Exchange (ETDEWEB)

    Shrestha, Som S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Desjarlais, Andre Omer [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Atchley, Jerald Allen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-11-01

    Gas filled insulation panels (GFP) are very light weight and compact (when uninflated) advanced insulation products. GFPs consist of multiple layers of thin, low emittance (low-e) metalized aluminum. When expanded, the internal, low-e aluminum layers form a honeycomb structure. These baffled polymer chambers are enveloped by a sealed barrier and filled with either air or a low-conductivity gas. The sealed exterior aluminum foil barrier films provide thermal resistance, flammability protection, and properties to contain air or a low conductivity inert gas. This product was initially developed with a grant from the U.S. Department of Energy. The unexpanded product is nearly flat for easy storage and transport. Therefore, transportation volume and weight of the GFP to fill unit volume of wall cavity is much smaller compared to that of other conventional insulation products. This feature makes this product appealing to use at Army Contingency Basing, when transportation cost is significant compared to the cost of materials. The objective of this study is to evaluate thermal performance of walls, similar to those used at typical Barracks Hut (B-Hut) hard shelters, when GFPs are used in the wall cavities. Oak Ridge National Laboratory (ORNL) tested performance of the wall in the rotatable guarded hotbox (RGHB) according to the ASTM C 1363 standard test method.

  6. Evaluation of mechanical and thermal properties of insulation materials for HTS power devices at liquid nitrogen temperature

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hyung Seop; Diaz, Mark Angelo [Dept. of Mechanical Design Engineering, Andong National University, Andong (Korea, Republic of)

    2017-06-15

    In superconducting power devices including power cables in which high temperature superconducting (HTS) tapes are utilized, a reliable electrical insulation should be achieved for its maximum performance. For an efficient design of HTS superconducting devices, a comparative evaluation of the mechanical and thermal propperties for various insulation materials at cryogenic temperatures is required. Especially, in the process of the property evaluation of the sheet-shaped insulation materials, anisotropy according to the machining direction should be considered because the mechanical and thermal properties are significantly influenced by the sample orientation. In this study, the cryogenic thermal and mechanical properties of various insulation material sheets such as PPLP, Cryoflex, Teflon, and Kapton were determined considering sample orientation. All samples tested at cryogenic temperature showed significantly higher tensile strength as compared with that of room temperature. The ultimate tensile strength at both temperature conditions significantly depended upon the sample orientation. The thermal properties of the insulation materials exhibited a slight difference among samples depending on the orientation: for the PPLP and Cryoflex, the CD orientation showed larger thermal contraction up to 77 K as compared to the MD one. MD samples in PPLP and Cryoflex showed a lower CTE and thermal contraction which made it more promising as an insulation material due to its comparable CTE with HTS CC tapes.

  7. Experimental Study on Downwardly Spreading Flame over Inclined Polyethylene-insulated Electrical Wire with Applied AC Electric Fields

    KAUST Repository

    Lim, Seung Jae

    2014-12-30

    An experimental study on downwardly spreading flame over slanted electrical wire, which is insulated by Polyethylene (PE), was conducted with applied AC electric fields. The result showed that the flame spread rate decreased initially with increase in inclination angle of wire and then became nearly constant. The flame shape was modified significantly with applied AC electric field due to the effect of ionic wind. Such a variation in flame spread rate could be explained by a thermal balance mechanism, depending on flame shape and slanted direction of flame. Extinction of the spreading flame was not related to angle of inclination, and was described well by a functional dependency upon the frequency and voltage at extinction.

  8. HEAT TRANSFER THROUGH CYANATE ESTER EPOXY MIX AND EPOXY GPAP–DETDA ELECTRICAL INSULATIONS AT SUPERFLUID HELIUM TEMPERATURE

    CERN Document Server

    Pietrowicz, S; Canfer, S; Jones, S; Baudouy, B

    2011-01-01

    In the framework of the European project EuCARD (FP7) aiming at constructing a high magnetic field accelerator magnet of 13 T with Nb3Sn superconducting cables, new electrical insulation are thermally tested. This technology will use “conventional” electrical insulation in combination with pressurized superfluid helium (He II) or saturated helium at atmospheric pressure as coolant. Two composite insulation systems composed of cyanate ester epoxy mix or a tri-functional epoxy (TGPAP-DETDA) with fiberglass tape frame, have been chosen as potential candidates. The knowledge of their thermal properties is necessary for the thermal design and therefore samples have been tested in pressurized He II where heat is applied perpendicularly to the fibers between 1.6 K and 2.0 K. Overall thermal resistance is determined as a function of temperature and the results are compared with other electrical insulation systems used for accelerator magnets.

  9. Survey and evaluation of available thermal insulation materials for use on solar heating and cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    1980-03-01

    This is the final report of a survey and evaluation of insulation materials for use with components of solar heating and cooling systems. The survey was performed by mailing questionnaires to manufacturers of insulation materials and by conducting an extensive literature search to obtain data on relevant properties of various types of insulation materials. The study evaluated insulation materials for active and passive solar heating and cooling systems and for multifunction applications. Primary and secondary considerations for selecting insulation materials for various components of solar heating and cooling systems are presented.

  10. Electrically controlled crossing of energy levels in quantum dots in two-dimensional topological insulators

    Energy Technology Data Exchange (ETDEWEB)

    Sukhanov, Aleksei A.

    2017-05-15

    We study the energy spectra of bound states in quantum dots (QDs) formed by an electrostatic potential in two-dimensional topological insulator (TI) and their transformation with changes in QD depth and radius. It is found that, unlike a trivial insulator, the energy difference between the levels of the ground state and first excited state can decrease with decreasing the radius and increasing the depth of the QD so that these levels intersect under some critical condition. The crossing of the levels results in unusual features of optical properties caused by intraceneter electron transitions. In particular, it leads to significant changes of light absorption due to electron transitions between such levels and to the transient electroluminescence induced by electrical tuning of QD and TI parameters. In the case of magnetic TIs, the polarization direction of the absorbed or emitted circularly polarized light is changed due to the level crossing.

  11. Side-by-Side Field Evaluation of Highly Insulating Windows in the PNNL Lab Homes

    Energy Technology Data Exchange (ETDEWEB)

    Widder, Sarah H.; Parker, Graham B.; Baechler, Michael C.; Bauman, Nathan N.

    2012-08-01

    To examine the energy, air leakage, and thermal performance of highly insulating windows, a field evaluation was undertaken in a matched pair of all-electric, factory-built “Lab Homes” located on the Pacific Northwest National Laboratory (PNNL) campus in Richland, Washington. The “baseline” Lab Home B was retrofitted with “standard” double-pane clear aluminum-frame slider windows and patio doors, while the “experimental” Lab Home A was retrofitted with Jeld-Wen® triple-pane vinyl-frame slider windows and patio doors with a U-factor of 0.2 and solar heat gain coefficient of 0.19. To assess the window, the building shell air leakage, energy use, and interior temperatures of each home were compared during the 2012 winter heating and summer cooling seasons. The measured energy savings in Lab Home B averaged 5,821 watt-hours per day (Wh/day) during the heating season and 6,518 Wh/day during the cooling season. The overall whole-house energy savings of Lab Home B compared to Lab Home A are 11.6% ± 1.53% for the heating season and 18.4 ± 2.06% for the cooling season for identical occupancy conditions with no window coverings deployed. Extrapolating these energy savings numbers based on typical average heating degree days and cooling degree days per year yields an estimated annual energy savings of 12.2%, or 1,784 kWh/yr. The data suggest that highly insulating windows are an effective energy-saving measure that should be considered for high-performance new homes and in existing retrofits. However, the cost effectiveness of the measure, as determined by the simple payback period, suggests that highly insulating window costs continue to make windows difficult to justify on a cost basis alone. Additional reductions in costs via improvements in manufacturing and/or market penetration that continue to drive down costs will make highly insulating windows much more viable as a cost-effective energy efficiency measure. This study also illustrates that highly

  12. Mechanically Stretchable and Electrically Insulating Thermal Elastomer Composite by Liquid Alloy Droplet Embedment

    Science.gov (United States)

    Jeong, Seung Hee; Chen, Si; Huo, Jinxing; Gamstedt, Erik Kristofer; Liu, Johan; Zhang, Shi-Li; Zhang, Zhi-Bin; Hjort, Klas; Wu, Zhigang

    2015-01-01

    Stretchable electronics and soft robotics have shown unsurpassed features, inheriting remarkable functions from stretchable and soft materials. Electrically conductive and mechanically stretchable materials based on composites have been widely studied for stretchable electronics as electrical conductors using various combinations of materials. However, thermally tunable and stretchable materials, which have high potential in soft and stretchable thermal devices as interface or packaging materials, have not been sufficiently studied. Here, a mechanically stretchable and electrically insulating thermal elastomer composite is demonstrated, which can be easily processed for device fabrication. A liquid alloy is embedded as liquid droplet fillers in an elastomer matrix to achieve softness and stretchability. This new elastomer composite is expected useful to enhance thermal response or efficiency of soft and stretchable thermal devices or systems. The thermal elastomer composites demonstrate advantages such as thermal interface and packaging layers with thermal shrink films in transient and steady-state cases and a stretchable temperature sensor. PMID:26671673

  13. Evaluation of Fire Test Methods for Aircraft Thermal Acoustical Insulation

    Science.gov (United States)

    1997-09-01

    This report presents the results of laboratory round robin flammability testing performed on thermal acoustical insulation blankets and the films used as insulation coverings. This work was requested by the aircraft industry as a result of actual inc...

  14. Field evaluation of reflective insulation in south east Asia

    Science.gov (United States)

    Teh, Khar San; Yarbrough, David W.; Lim, Chin Haw; Salleh, Elias

    2017-12-01

    The objective of this research was to obtain thermal performance data for reflective insulations in a South East Asia environment. Thermal resistance data (RSI, m2 ṡ K/W) for reflective insulations are well established from 1-D steady-state tests, but thermal data for reflective insulation in structures like those found in South East Asia are scarce. Data for reflective insulations in South East Asia will add to the worldwide database for this type of energy-conserving material. RSI were obtained from heat flux and temperature data of three identical structures in the same location. One unit did not have insulation above the ceiling, while the second and third units were insulated with reflective insulation with emittance less than 0.05. RSI for the uninsulated test unit varied from 0.37 to 0.40 m2 ṡ K/W. RSI for a single-sheet reflective insulation (woven foil) varied from 2.15 to 2.26 m2 ṡ K/W, while bubble-foil insulation varied from 2.69 to 3.09 m2 ṡ K/W. The range of RSI values resulted from differences in the spacing between the reflective insulation and the roof. In addition, the reflective insulation below the roof lowered attic temperatures by as much as 9.7° C. Reductions in ceiling heat flux of 80 to 90% relative to the uninsulated structure, due to the reflective insulation, were observed.

  15. Field evaluation of reflective insulation in south east Asia

    Directory of Open Access Journals (Sweden)

    Teh Khar San

    2017-12-01

    Full Text Available The objective of this research was to obtain thermal performance data for reflective insulations in a South East Asia environment. Thermal resistance data (RSI, m2 ⋅ K/W for reflective insulations are well established from 1-D steady-state tests, but thermal data for reflective insulation in structures like those found in South East Asia are scarce. Data for reflective insulations in South East Asia will add to the worldwide database for this type of energy-conserving material. RSI were obtained from heat flux and temperature data of three identical structures in the same location. One unit did not have insulation above the ceiling, while the second and third units were insulated with reflective insulation with emittance less than 0.05. RSI for the uninsulated test unit varied from 0.37 to 0.40 m2 ⋅ K/W. RSI for a single-sheet reflective insulation (woven foil varied from 2.15 to 2.26 m2 ⋅ K/W, while bubble-foil insulation varied from 2.69 to 3.09 m2 ⋅ K/W. The range of RSI values resulted from differences in the spacing between the reflective insulation and the roof. In addition, the reflective insulation below the roof lowered attic temperatures by as much as 9.7° C. Reductions in ceiling heat flux of 80 to 90% relative to the uninsulated structure, due to the reflective insulation, were observed.

  16. An innovative hybrid insulation switch to enable/disable electrical loads without overvoltages

    Science.gov (United States)

    Zajkowski, Konrad

    2017-10-01

    This article describes an innovative project for the design of a low voltage switch to enable/disable electrical devices from an AC source, which is characterised by the absence of arc ignition. When powered off, this device is a galvanically separated of the receiver from the power source. The proposed hybrid interaction has two switches: the insulating switch made of mechanical contacts and the current switch made of elements from power electronics. The absence of arc ignition increases the equipment uptime and improves the comfort-powered receiver and equipment located nearby.

  17. Electrical control of the superconducting-to-insulating transition in graphene-metal hybrids.

    Science.gov (United States)

    Allain, Adrien; Han, Zheng; Bouchiat, Vincent

    2012-05-20

    Graphene is a sturdy and chemically inert material exhibiting an exposed two-dimensional electron gas of high mobility. These combined properties enable the design of graphene composites, based either on covalent or non-covalent coupling of adsorbates, or on stacked and multilayered heterostructures. These systems have shown tunable electronic properties such as bandgap engineering, reversible metal-insulating transition or supramolecular spintronics. Tunable superconductivity is expected as well, but experimental realization is lacking. Here, we show experiments based on metal-graphene hybrid composites, enabling the tunable proximity coupling of an array of superconducting nanoparticles of tin onto a macroscopic graphene sheet. This material allows full electrical control of the superconductivity down to a strongly insulating state at low temperature. The observed gate control of superconductivity results from the combination of a proximity-induced superconductivity generated by the metallic nanoparticle array with the two-dimensional and tunable metallicity of graphene. The resulting hybrid material behaves, as a whole, like a granular superconductor showing universal transition threshold and localization of Cooper pairs in the insulating phase. This experiment sheds light on the emergence of superconductivity in inhomogeneous superconductors, and more generally, it demonstrates the potential of graphene as a versatile building block for the realization of superconducting materials.

  18. An effect of heat insulation parameters on thermal losses of water-cooled roofs for secondary steelmaking electric arc furnaces

    Directory of Open Access Journals (Sweden)

    E. Mihailov

    2016-07-01

    Full Text Available The aim of this work is research in the insulation parameters effect on the thermal losses of watercooled roofs for secondary steelmaking electric arc furnaces. An analytical method has been used for the investigation in heat transfer conditions in the working area. The results of the research can be used to choose optimal cooling parameters and select a suitable kind of insulation for water-cooled surfaces.

  19. Heavily Cr-doped (Bi,Sb2Te3 as a ferromagnetic insulator with electrically tunable conductivity

    Directory of Open Access Journals (Sweden)

    Yunbo Ou

    2016-08-01

    Full Text Available With molecular beam epitaxy we have grown Cry(BixSb1-x2-yTe3 thin films with homogeneous distribution of Cr dopants and Curie temperature up to 77 K. The films with Cr concentration y ≥ 0.39 are found to be topologically trivial, highly insulating ferromagnets, whose conductivity can be tuned over two orders of magnitude by gate voltage. The ferromagnetic insulators with electrically tunable conductivity can be used to realize the quantum anomalous Hall effect at higher temperature in topological insulator heterostructures and to develop field effect devices for spintronic applications.

  20. Electric-field control of spin-orbit torque in a magnetically doped topological insulator.

    Science.gov (United States)

    Fan, Yabin; Kou, Xufeng; Upadhyaya, Pramey; Shao, Qiming; Pan, Lei; Lang, Murong; Che, Xiaoyu; Tang, Jianshi; Montazeri, Mohammad; Murata, Koichi; Chang, Li-Te; Akyol, Mustafa; Yu, Guoqiang; Nie, Tianxiao; Wong, Kin L; Liu, Jun; Wang, Yong; Tserkovnyak, Yaroslav; Wang, Kang L

    2016-04-01

    Electric-field manipulation of magnetic order has proved of both fundamental and technological importance in spintronic devices. So far, electric-field control of ferromagnetism, magnetization and magnetic anisotropy has been explored in various magnetic materials, but the efficient electric-field control of spin-orbit torque (SOT) still remains elusive. Here, we report the effective electric-field control of a giant SOT in a Cr-doped topological insulator (TI) thin film using a top-gate field-effect transistor structure. The SOT strength can be modulated by a factor of four within the accessible gate voltage range, and it shows strong correlation with the spin-polarized surface current in the film. Furthermore, we demonstrate the magnetization switching by scanning gate voltage with constant current and in-plane magnetic field applied in the film. The effective electric-field control of SOT and the giant spin-torque efficiency in Cr-doped TI may lead to the development of energy-efficient gate-controlled spin-torque devices compatible with modern field-effect semiconductor technologies.

  1. Electric-field control of spin-orbit torque in a magnetically doped topological insulator

    Science.gov (United States)

    Fan, Yabin; Kou, Xufeng; Upadhyaya, Pramey; Shao, Qiming; Pan, Lei; Lang, Murong; Che, Xiaoyu; Tang, Jianshi; Montazeri, Mohammad; Murata, Koichi; Chang, Li-Te; Akyol, Mustafa; Yu, Guoqiang; Nie, Tianxiao; Wong, Kin L.; Liu, Jun; Wang, Yong; Tserkovnyak, Yaroslav; Wang, Kang L.

    2016-04-01

    Electric-field manipulation of magnetic order has proved of both fundamental and technological importance in spintronic devices. So far, electric-field control of ferromagnetism, magnetization and magnetic anisotropy has been explored in various magnetic materials, but the efficient electric-field control of spin-orbit torque (SOT) still remains elusive. Here, we report the effective electric-field control of a giant SOT in a Cr-doped topological insulator (TI) thin film using a top-gate field-effect transistor structure. The SOT strength can be modulated by a factor of four within the accessible gate voltage range, and it shows strong correlation with the spin-polarized surface current in the film. Furthermore, we demonstrate the magnetization switching by scanning gate voltage with constant current and in-plane magnetic field applied in the film. The effective electric-field control of SOT and the giant spin-torque efficiency in Cr-doped TI may lead to the development of energy-efficient gate-controlled spin-torque devices compatible with modern field-effect semiconductor technologies.

  2. Evolution of the electric potential of an insulator under charged particle impact

    Science.gov (United States)

    Giglio, E.; Guillous, S.; Cassimi, A.; Zhang, H. Q.; Nagy, G. U. L.; Tőkési, K.

    2017-03-01

    Insulating glass capillaries have been shown to lead to ion transmission without any change in either the ion charge state or in the ion kinetic energy. This surprising process has been attributed to a self-organized distribution of charge patches creating the necessary guiding electric potential on the capillary walls. By the use of our original electrometer, it has been possible to measure and monitor simultaneously and in a nondestructive way the electric potential and the transmitted beam intensity during the charging up by an Ar+ ion beam. We show that glass microcapillaries can reach potentials higher than 500 V, even in the case of singly charged ions, opening the possibility of high transmission rates and providing a renewed sight into ion beam transport by tapered capillaries. The setup, also suitable for the determination of leakage currents governing the capillary potential dynamics, allowed one to evidence that secondary electrons may strongly affect the rise of the capillary potential and consequently avoid Coulomb blocking of the beam transmission across insulating capillaries.

  3. All-electrical generation of spin-polarized currents in quantum spin Hall insulators

    Science.gov (United States)

    Tao, L. L.; Cheung, K. T.; Zhang, L.; Wang, J.

    2017-03-01

    The control and generation of spin-polarized current (SPC) without magnetic materials and an external magnetic field is a big challenge in spintronics and normally requires a spin-flip mechanism. In this Rapid Communication, we show the theoretical discovery of all-electrical generation of SPC without relying on spin-flip spin-orbit coupling (SOC). We find that the SPC can be produced as long as an energy-dependent phase difference between the spin up and down electrons can be established. We verify this through quantum transport calculations on a gated stanene zigzag nanoribbon, which is a quantum spin Hall (QSH) insulator. Our calculations indicate that the transient current as well as ac conductance are significantly spin polarized, which results from the genetic phase difference between spin up and down electrons after traversing the system. Our results are robust against edge imperfections and generally valid for other QSH insulators, such as silicene and germanene, etc. These findings establish a different route for generating SPCs by purely electrical means and open the door for interesting applications of semiconductor spintronics.

  4. Electric field-triggered metal-insulator transition resistive switching of bilayered multiphasic VOx

    Science.gov (United States)

    Won, Seokjae; Lee, Sang Yeon; Hwang, Jungyeon; Park, Jucheol; Seo, Hyungtak

    2017-10-01

    Electric field-triggered Mott transition of VO2 for next-generation memory devices with sharp and fast resistance-switching response is considered to be ideal but the formation of single-phase VO2 by common deposition techniques is very challenging. Here, VOx films with a VO2-dominant phase for a Mott transition-based metal-insulator transition (MIT) switching device were successfully fabricated by the combined process of RF magnetron sputtering of V metal and subsequent O2 annealing to form. By performing various material characterizations, including scanning transmission electron microscopyelectron energy loss spectroscopy, the film is determined to have a bilayer structure consisting of a VO2-rich bottom layer acting as the Mott transition switching layer and a V2O5/V2O3 mixed top layer acting as a control layer that suppresses any stray leakage current and improves cyclic performance. This bilayer structure enables excellent electric field-triggered Mott transition-based resistive switching of Pt- VOx-Pt metal-insulator-metal devices with a set/reset current ratio reaching 200, set/reset voltage of less than 2.5 V, and very stable DC cyclic switching upto 120 cycles with a great set/reset current and voltage distribution less than 5% of standard deviation at room temperature, which are specifications applicable for neuromorphic or memory device applications.[Figure not available: see fulltext.

  5. Electric field-triggered metal-insulator transition resistive switching of bilayered multiphasic VOx

    Science.gov (United States)

    Won, Seokjae; Lee, Sang Yeon; Hwang, Jungyeon; Park, Jucheol; Seo, Hyungtak

    2018-01-01

    Electric field-triggered Mott transition of VO2 for next-generation memory devices with sharp and fast resistance-switching response is considered to be ideal but the formation of single-phase VO2 by common deposition techniques is very challenging. Here, VOx films with a VO2-dominant phase for a Mott transition-based metal-insulator transition (MIT) switching device were successfully fabricated by the combined process of RF magnetron sputtering of V metal and subsequent O2 annealing to form. By performing various material characterizations, including scanning transmission electron microscopy-electron energy loss spectroscopy, the film is determined to have a bilayer structure consisting of a VO2-rich bottom layer acting as the Mott transition switching layer and a V2O5/V2O3 mixed top layer acting as a control layer that suppresses any stray leakage current and improves cyclic performance. This bilayer structure enables excellent electric field-triggered Mott transition-based resistive switching of Pt-VOx-Pt metal-insulator-metal devices with a set/reset current ratio reaching 200, set/reset voltage of less than 2.5 V, and very stable DC cyclic switching upto 120 cycles with a great set/reset current and voltage distribution less than 5% of standard deviation at room temperature, which are specifications applicable for neuromorphic or memory device applications. [Figure not available: see fulltext.

  6. Evaluation of the Fretting Resistance of the High Voltage Insulation on the ITER Magnet Feeder Busbars

    Science.gov (United States)

    Clayton, N.; Crouchen, M.; Evans, D.; Gung, C.-Y.; Su, M.; Devred, A.; Piccin, R.

    2017-12-01

    The high voltage (HV) insulation on the ITER magnet feeder superconducting busbars and current leads will be prepared from S-glass fabric, pre-impregnated with an epoxy resin, which is interleaved with polyimide film and wrapped onto the components and cured during feeder manufacture. The insulation architecture consists of nine half-lapped layers of glass/Kapton, which is then enveloped in a ground-screen, and two further half-lapped layers of glass pre-preg for mechanical protection. The integrity of the HV insulation is critical in order to inhibit electrical arcs within the feeders. The insulation over the entire length of the HV components (bus bar, current leads and joints) must provide a level of voltage isolation of 30 kV. In operation, the insulation on ITER busbars will be subjected to high mechanical loads, arising from Lorentz forces, and in addition will be subjected to fretting erosion against stainless steel clamps, as the pulsed nature of some magnets results in longitudinal movement of the busbar. This work was aimed at assessing the wear on, and the changes in, the electrical properties of the insulation when subjected to typical ITER operating conditions. High voltage tests demonstrated that the electrical isolation of the insulation was intact after the fretting test.

  7. Transforming common III-V/II-VI insulating building blocks into topological heterostructure via the intrinsic electric polarization

    Science.gov (United States)

    Zunger, Alex; Zhang, Xiuwen; Abdalla, Leonardo; Liu, Qihang

    Currently known topological insulators (TIs) are limited to narrow gap compounds incorporating heavy elements, thus severely limiting the material pool available for such applications. We show how a heterovalent superlattice made of common semiconductor building blocks can transform its non-TI components into a topological heterostructure. The heterovalent nature of such interfaces sets up, in the absence of interfacial atomic exchange, a natural internal electric field that along with the quantum confinement leads to band inversion, transforming these semiconductors into a topological phase while also forming a giant Rashba spin splitting. We demonstrate this paradigm of designing TIs from ordinary semiconductors via first-principle calculations on III-V/II-VI superlattice InSb/CdTe. We illustrate the relationship between the interfacial stability and the topological transition, finding a ``window of opportunity'' where both conditions can be optimized. This work illustrates the general principles of co-evaluation of TI functionality with thermodynamic stability as a route of identifying realistic combination of common insulators that could produce topological heterostructures. This work was supported by Basic Energy Science, MSE division (Grant DE-FG02-13ER46959).

  8. Electric field driven destabilization of the insulating state in nominally pure LaMnO3.

    Science.gov (United States)

    Nath, Rajib; Raychaudhuri, A K; Mukovskii, Ya M; Mondal, Parthasarathi; Bhattacharya, Dipten; Mandal, P

    2013-04-17

    We report an electric field driven destabilization of the insulating state in nominally pure LaMnO3 single crystal with a moderate field which leads to a resistive state transition below 300 K. The transition is between the insulating state in LaMnO3 and a high resistance bad metallic state that has a temperature independent resistivity. The transition occurs at a threshold field (Eth) that shows a steep enhancement on cooling. While at lower temperatures the transition is sharp and involves a large change in resistance, it softens on heating and is eventually absent above 280 K. When the Mn(4+) content is increased by Sr substitution up to x = 0.1, the observed transition, although observable in a certain temperature range, softens considerably. This observation has been explained as a bias driven percolation type transition between two co-existing phases, where the majority phase is a charge and orbitally ordered polaronic insulating phase and the minority phase is a bad metallic phase. The mobile fraction f of the bad metallic phase deduced from the experimental data follows an activated kinetics as f = fo(E)exp(-Δ/kBT) with the activation energy Δ ≈ 200 meV, and the pre-factor fo(E) is a strong function of the field that leads to a rapid enhancement of f on application of field, leading to the resistive state transition. We suggest likely scenarios for such co-existing phases in nominally pure LaMnO3 that can lead to the bias driven percolation type transition.

  9. Electric strength of insulation on superhigh-voltage overhead transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Danis, J.; Kromer, I.L.

    1979-09-01

    Insulation for superhigh-voltage overhead transmission lines is selected on the basis of reliability during switching overvoltages and extreme changes in ambient conditions. A study of 400 kV and 750 kV insulator strings, porcelain and glass, respectively, was made to determine their performance with dusty or moist surface under these severe conditions as expected in service. Four different configurations of a double string suspended from a cross beam 30 m above ground and at various horizontal distances from lateral poles were tested. The risetime of aperiodic voltage pulses was varied from 35 ..mu..s (below critical) to 1200..mu..s (above critical) and their duration was varied from 1000 to 10,500 ..mu..s, the voltage level changed in 5% steps and successive pulses applied in 30 to 40 s intervals. The 50%-discharge voltage was estimated by the up and down method and the readings evaluated statistically by Student's method. The results yielded the voltage-time characteristics of these insulator strings, with the dip of the 50%-discharge voltage down to its minimum critical level corresponding to an overvoltage pulse with the critical risetime. Further analysis yields also the risk and the number of flashhovers, depending on the contamination distribution density, on the overvoltage amplitude distribution density, and on the number of weak spots. Contamination increases the probable number of flashovers during switching by 30 to 50%.

  10. Effectiveness Analysis and Temperature Effect Mechanism on Chemical and Electrical-Based Transformer Insulation Diagnostic Parameters Obtained from PDC Data

    Directory of Open Access Journals (Sweden)

    Hanbo Zheng

    2018-01-01

    Full Text Available The dielectric monitoring/diagnostic tool, such as Polarization and Depolarization Current (PDC measurement, is now being widely applied to obtain the status of deteriorated transformers around the world. Nowadays, several works have reported that the chemical and electrical-based transformer insulation diagnostic parameters (absorption ratio, polarization index, paper conductivity, oil conductivity, insulation resistance, etc. can be easily calculated from the PDC data. It is a fact that before using these parameters to obtain the status of deteriorated transformers, the power engineers should prudently investigate the effectiveness of these parameters. However, there are few papers that investigate the important issue. In addition, the understanding of temperature effect mechanism on these parameters should also be prudently studied. In the present work, we firstly prepare several oil-impregnated pressboard specimens with various insulation statuses by using a sequence of thermal ageing and moisture absorption experiments launched in the laboratory, and then the PDC measurement is performed to obtain the chemical and electrical-based transformer insulation diagnostic parameters. Finally, we systematically interpret the effectiveness and temperature effect mechanism on these chemical and electrical-based transformer insulation diagnostic parameters.

  11. Electrical resistivity of assembled transparent inorganic oxide nanoparticle thin layers: influence of silica, insulating impurities, and surfactant layer thickness.

    Science.gov (United States)

    Bubenhofer, Stephanie B; Schumacher, Christoph M; Koehler, Fabian M; Luechinger, Norman A; Sotiriou, Georgios A; Grass, Robert N; Stark, Wendelin J

    2012-05-01

    The electrical properties of transparent, conductive layers prepared from nanoparticle dispersions of doped oxides are highly sensitive to impurities. Production of cost-effective thin conducting films for consumer electronics often employs wet processing such as spin and/or dip coating of surfactant-stabilized nanoparticle dispersions. This inherently results in entrainment of organic and inorganic impurities into the conducting layer leading to largely varying electrical conductivity. Therefore, this study provides a systematic investigation on the effect of insulating surfactants, small organic molecules and silica in terms of pressure dependent electrical resistivity as a result of different core/shell structures (layer thickness). Application of high temperature flame synthesis gives access to antimony-doped tin oxide (ATO) nanoparticles with high purity. This well-defined starting material was then subjected to representative film preparation processes using organic additives. In addition ATO nanoparticles were prepared with a homogeneous inorganic silica layer (silica layer thickness from 0.7 to 2 nm). Testing both organic and inorganic shell materials for the electronic transport through the nanoparticle composite allowed a systematic study on the influence of surface adsorbates (e.g., organic, insulating materials on the conducting nanoparticle's surface) in comparison to well-known insulators such as silica. Insulating impurities or shells revealed a dominant influence of a tunneling effect on the overall layer resistance. Mechanical relaxation phenomena were found for 2 nm insulating shells for both large polymer surfactants and (inorganic) SiO(2) shells.

  12. Concepts for evaluation of sound insulation of dwellings - from chaos to consensus?

    DEFF Research Database (Denmark)

    Rasmussen, Birgit; Rindel, Jens Holger

    2005-01-01

    Legal sound insulation requirements have existed more than 50 years in some countries, and single-number quantities for evaluation of sound insulation have existed nearly as long time. However, the concepts have changed considerably over time from simple arithmetic averaging of frequency bands......¬ments and classification schemes revealed significant differences of concepts. The paper summarizes the history of concepts, the disadvantages of the present chaos and the benefits of consensus concerning concepts for airborne and impact sound insulation between dwellings and airborne sound insulation of facades...

  13. All-electric spin modulator based on a two-dimensional topological insulator

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Xianbo; Ai, Guoping [School of Computer Science, Jiangxi University of Traditional Chinese Medicine, Nanchang 330004 (China); Liu, Ying; Yang, Shengyuan A., E-mail: shengyuan-yang@sutd.edu.sg [Research Laboratory for Quantum Materials, Singapore University of Technology and Design, Singapore 487372 (Singapore); Liu, Zhengfang [School of Science, East China Jiaotong University, Nanchang 330013 (China); Zhou, Guanghui, E-mail: ghzhou@hunnu.edu.cn [Key Laboratory for Low-Dimensional Structures and Quantum Manipulation (Ministry of Education), and Synergetic Innovation Center for Quantum Effects and Applications, Hunan Normal University, Changsha 410081 (China)

    2016-01-18

    We propose and investigate a spin modulator device consisting of two ferromagnetic leads connected by a two-dimensional topological insulator as the channel material. It exploits the unique features of the topological spin-helical edge states, such that the injected carriers with a non-collinear spin-polarization direction would travel through both edges and show interference effect. The conductance of the device can be controlled in a simple and all-electric manner by a side-gate voltage, which effectively rotates the spin-polarization of the carrier. At low voltages, the rotation angle is linear in the gate voltage, and the device can function as a good spin-polarization rotator by replacing the drain electrode with a non-magnetic material.

  14. Heat transfer through the electrical insulation of Nb3Sn cables

    CERN Document Server

    Granieri, P; van Weelderen, R

    2014-01-01

    For the LHC upgrade projects, CERN will rely on the Nb3Sn technology to build high field dipole and quadrupole superconducting magnets. In the frame of this R&D program, cooling studies are carried out to determine the heat extraction from this new type of accelerator magnets and the relevant quench limits. In this paper we present and discuss experimental results of heat transfer through the electrical insulation of Nb3Sn cables. A cable-stack was prepared using fiberglass sleeves and CTD-101K impregnation resin. Two different measurement methods were compared, consisting of instrumenting the sample before or after the vacuum impregnation. The tests were performed both in 1.9 K superfluid and 4.2 K liquid helium baths, using different heating configurations. We also present results of the numerical model developed to reproduce the experimental results.

  15. Identification of Droplet-Flow-Induced Electric Energy on Electrolyte-Insulator-Semiconductor Structure.

    Science.gov (United States)

    Park, Junwoo; Song, Suhwan; Yang, YoungJun; Kwon, Soon-Hyung; Sim, Eunji; Kim, Youn Sang

    2017-08-16

    Recently, various energy transducers driven by the relative motion of solids and liquids have been demonstrated. However, in relation to the energy transducer, a proper understanding of the dynamic behavior of ions remains unclear. Moreover, the energy density is low for practical usage mainly due to structural limitations, a lack of material development stemming from the currently poor understanding of the mechanisms, and the intermittently generated electricity given the characteristics of the water motion (pulsed signals). Here, we verify a hypothesis pertaining to the ion dynamics which govern the operation mechanism of the transducer. In addition, we demonstrate enhanced energy transducer to convert the mechanical energy of flowing water droplets into continuous electrical energy using an electrolyte-insulator-semiconductor structure as a device structure. The output power per droplet mass and the ratio of generated electric energy to the kinetic energy of water drops are 0.149v2 mW·g-1·m-2·s2 and 29.8%, respectively, where v is the speed of the water droplet.

  16. The Dynamics of the Electric Field Distribution in the Surface of Insulating Film Irradiated by Air Ions

    Directory of Open Access Journals (Sweden)

    Julionas KALADE

    2016-05-01

    Full Text Available When deposited on a surface, electric charge usually accumulates near the tips of surface irregularities, from where it can be transferred to nearby objects due to ionization of ambient air. The amount of transferred charge, the rate of charge transfer, the size of the charged spot (e.g., on the surface of an insulator and its tendency to spread will depend on properties of air during electric discharge, on the magnitude of charge accumulated at the tip of an object, on possibilities for replenishing that charge, on the time spent for charge transfer from the tip onto the insulating layer, on properties of the insulating layer, etc. Those properties are discussed in this work by comparing the results of measurements and theoretical analysis.

  17. Density-Polarization Functional Theory of the response of a periodic insulating solid to an electric field.

    OpenAIRE

    Gonze, X.; Ghosez, Ph.; Godby, R. W.; .

    1995-01-01

    The response of an infinite, periodic, insulating, solid to an infinitesimally small electric field is investigated in the framework of Density Functional Theory. We find that the applied perturbing potential is not a unique functional of the periodic density change~: it depends also on the change in the macroscopic {\\em polarization}. Moreover, the dependence of the exchange-correlation energy on polarization induces an exchange-correlation electric field. These effects are exhibited for a m...

  18. Density-polarisation functional theory of the response of a periodic insulating solid to an electric field

    OpenAIRE

    Godby, R. W.; Gonze, X.; Ghosez, P

    1995-01-01

    The response of an infinite, periodic, insulating, solid to an infinitesimally small electric field is investigated in the framework of Density Functional Theory. We find that the applied perturbing potential is not a unique functional of the periodic density change~: it depends also on the change in the macroscopic {\\em polarization}. Moreover, the dependence of the exchange-correlation energy on polarization induces an exchange-correlation electric field. These effects are exhibited for a m...

  19. Dielectric and insulating properties of an acrylic DEA material at high near-DC electric fields

    Science.gov (United States)

    Di Lillo, L.; Schmidt, A.; Bergamini, A.; Ermanni, P.; Mazza, E.

    2011-04-01

    A number of adaptive structure applications call for the generation of intense electric fields (in excess of 70 MV/m). Such intense fields across the thickness of a thin polymer dielectric layer are typically used to exploit the direct electromechanical coupling in the form of a Maxwell stress: (see manuscript) Where V/d is the applied field, ɛ0 is the permittivity of vacuum and ɛ is the relative permittivity of the material. The field that can be applied to the dielectric is limited by the dielectric strength of the material. Below the limit set by the breakdown, the material is generally assumed to have a field independent dielectric constant and to be a perfect insulator, i.e. to have an infinite volume resistivity. While extensive investigations about the mechanical properties of the materials used for electronic Dielectric Elastomer Actuators (DEA) are available from literature, the results of the investigation of the insulating and dielectric properties of these materials, especially under conditions (electric field and frequency) similar to the ones encountered during operation are not available. In the present contribution, we present a method and a set-up for the measurement of the electric properties of thin polymer films, such as the ones used for the fabrication of electronic DEAs, under conditions close to operations. The method and setup where developed to investigate the properties of 'stiff' thin polymer films, such as Polyimide or Polyvinylidenefluoride, used for Electro-Bonded Laminates (EBLs). The properties of the well known VHB 4910 acrylic elastomer are presented to illustrate how the permittivity and the leakage current can be measured as a function of the electric field and the deformation state, using the proposed set-up. The material properties were measured on membranes under different fixed pre-stretch conditions (λ 1, λ2=3, 4, 5), in order to eliminate effects due to the change in sample geometry, using gold sputtered electrodes, 20

  20. Evaluation of the thermal insulation of clothing of infants sleeping outdoors in Northern winter.

    Science.gov (United States)

    Tourula, Marjo; Fukazawa, Takako; Isola, Arja; Hassi, Juhani; Tochihara, Yutaka; Rintamäki, Hannu

    2011-04-01

    It is a common practice in Northern countries that children aged about 2 weeks to 2 years take their daytime sleep outdoors in prams in winter. The aim was to evaluate the thermal insulation of clothing of infants sleeping outdoors in winter. Clothing data of infants aged 3.5 months was collected, and sleep duration, skin and microclimate temperatures, humidity inside middle wear, air temperature and velocity of the outdoor environment were recorded during sleep taken outdoors (n = 34) and indoors (n = 33) in families' homes. The insulation of clothing ensembles was measured by using a baby-size thermal manikin, and the values were used for defining clothing insulation of the observed infants. Required clothing insulation for each condition was estimated according to ISO 11079. Clothing insulation did not correlate with ambient air temperature. The observed and required insulation of the study group was equal at about -5 °C, but overdressing existed in warmer and deficiency in thermal insulation in colder temperatures (r (s) 0.739, p insulation increased, the cooling rate of T (sk) increased linearly (r (s) 0.605, p thermal insulation for outdoor sleeping infants during northern winter. Therefore, the necessity for guidelines is obvious. The study provides information for adequate cold protection of infants sleeping in cold conditions.

  1. Standard Practice for Evaluating Thermal Insulation Materials for Use in Solar Collectors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1994-01-01

    1.1 This practice sets forth a testing methodology for evaluating the properties of thermal insulation materials to be used in solar collectors with concentration ratios of less than 10. Tests are given herein to evaluate the pH, surface burning characteristics, moisture adsorption, water absorption, thermal resistance, linear shrinkage (or expansion), hot surface performance, and accelerated aging. This practice provides a test for surface burning characteristics but does not provide a methodology for determining combustibility performance of thermal insulation materials. 1.2 The tests shall apply to blanket, rigid board, loose-fill, and foam thermal insulation materials used in solar collectors. Other thermal insulation materials shall be tested in accordance with the provisions set forth herein and should not be excluded from consideration. 1.3 The assumption is made that elevated temperature, moisture, and applied stresses are the primary factors contributing to the degradation of thermal insulation mat...

  2. Thermally conductive and electrically insulating EVA composite encapsulant for solar photovoltaic (PV cell

    Directory of Open Access Journals (Sweden)

    2008-05-01

    Full Text Available A new way of improving the heat dissipating ability and PV efficiency of the solar cells by enhancing the thermal conductivity of the rear EVA layer was reported. The thermal conductivity, electrical resistivity, degree of curing of the EVA encapsulating composites and the PV efficiency of the solar cells are investigated. Filling with the thermal conductive fillers enhances the thermal conductivity of the composites effectively. The thermal conductivity of the filler influences significantly the thermal conductivity of the composite at high filler loading (greater than 20 vol%. Thermal conductivities of the composites filled with SiC, ZnO or BN reach respectively 2.85, 2.26 and 2.08 W/m•K at filler content of 60 vol%. The composites filled with ZnO or BN exhibit superior electrical insulation to those filled with SiC or Al2O3. ZnO can promote the cross-linking reaction of the EVA matrix. The test results indicated that the EVA composite encapsulating rear films filled with thermal conductive fillers are able to improve the PV efficiency and the heat dissipating ability of the solar cell effectively.

  3. Measurement of insulating and dielectric properties of acrylic elastomer membranes at high electric fields

    Science.gov (United States)

    Di Lillo, L.; Schmidt, A.; Carnelli, D. A.; Ermanni, P.; Kovacs, G.; Mazza, E.; Bergamini, A.

    2012-01-01

    This work reports on the investigation of VHB 4910 acrylic elastomer insulating and dielectric properties. This material is widely exploited for the realization of actuators with large deformations, dielectric elastomer actuators (DEA), and belongs to the group of so-called electroactive polymers (EAP). Extensive investigations concerning its mechanical properties are available in literature while its electric behavior at working conditions has not received the same level of attention. In this work, the relative permittivity and the volume resistivity have been measured on VHB 4910 membranes under different fixed stretch conditions (λ1, λ2 = 3, 3.6, 4, 5) using circular gold electrodes sputtered onto both sides of the specimens. The measured values of relative permittivity are in fairly good agreement with the results previously published by other groups. The volume resistivity, at field values close to the operational ones, has shown a field-dependent behavior revealing dissipative properties that should be considered in real applications. Further, measurements on circular actuators verify these findings. Consequences for modeling of VHB 4910 are drawn and new material model parameters proposed to account for the value of relative permittivity at high electric fields.

  4. Electric controlling of surface metal-insulator transition in the doped BaTiO3 film

    Directory of Open Access Journals (Sweden)

    Wei Xun

    2017-07-01

    Full Text Available Based on first-principles calculations, the BaTiO3(BTO film with local La-doping is studied. For a selected concentration and position of doping, the surface metal-insulator transition occurs under the applied electric field, and the domain appears near the surface for both bipolar states. Furthermore, for the insulated surface state, i.e., the downward polarization state in the doped film, the gradient bandgap structure is achieved, which favors the absorption of solar energy. Our investigation can provide an alternative avenue in modification of surface property and surface screening effect in polar materials.

  5. Reusable surface insulation thermal protection systems test evaluation status

    Science.gov (United States)

    Strouhal, G.; Tillian, D. J.

    1973-01-01

    Changes in coating morphology of mullite, silica, and ceramic mullite fiber at two heating rates are described followed by a discussion of the changes in surface chemistry that occur during convective heating tests. Subsequently, the surface chemistry changes observed are compared to similar data obtained from radiantly heated coatings and the significance of the difference between the results is discussed. Finally, the changes in chemistry of the coatings in cross section before and after convectively heated cyclic testing are discussed and the significance of surface chemistry changes are described. Results indicate that the thermal conductivity of mullite surface insulation is higher than that of silica insulation, based on thermal response data. Acoustic excitation of cracked silica tiles does not lead to catastrophic failure such as spallation or tile loss. Cracks in mullite material after thermal exposure lead to fracturing of the coating and surface insulation material after acoustic excitation.

  6. Contribution to evaluation of power generator insulation aging due to long term service

    Energy Technology Data Exchange (ETDEWEB)

    Coletti, G.; Guastavino, F. (Genoa Univ. (Italy). Dip. di Ingegneria Elettrica)

    1991-01-01

    An evaluation of the insulating system status of two different large fossil- fuel power plant generators having a service life longer than 30 years is presented. Both insulations were based on mica splittings: one used a thermosetting resin, while the other one had a thermoplastic compound. A purposely devised testing program was carried out both on semicoils (and on smaller samples) taken from the windings which had been in long term service and on reference (same) semicoils kept stored for the same time period. The testing program involved visual, acoustic and microscopic examinations, partial discharges, loss tangent and depolarization current measurements, a dielectric proof test and thermo-physical analyses. The relevant results facilitated qualitative assessments of the noted ageing mechanisms and thus contributed to a wider diagnostic evaluation of the winding insulation status. In parallel, it was also possible to evaluate the capabilities of the single testing procedures adopted to discriminate between service aged and non-aged insulation systems.

  7. Evaluation of Electrical and Thermal Conductivity of Polymeric ...

    African Journals Online (AJOL)

    PROF HORSFALL

    for the electrical and thermal conductivities of the doped polymers it was observed that both conductivities .... ceramic insulators when very hot may conduct quite well. The more ... Doping also lead to the formation of polarons and bipolarons ...

  8. Evaluation of a strengthening and insulation system for high temperature BSCCO-2223 superconducting tape

    Energy Technology Data Exchange (ETDEWEB)

    King, C.; Mantone, A. [GE Medical Systems, Florence, SC (United States); Herd, K.; Laskaris, T. [GE Corp. Research and Development Center, Schenectady, NY (United States)

    1995-12-31

    Recent advances in BSCCO-2223 superconducting tape quality and length have led to demonstration programs for coil performance. The conductors in these coils need to be insulated without damage to the superconducting properties. A paper insulation process developed at the General Electric Company (GE) for low temperature superconducting Nb{sub 3}Sn tape has been modified to provide the same insulation system to high temperature (HTS) superconducting tapes, such as BSCCO-2223. In this paper, we report on the insulation process and its effect on the tape performance. Several long lengths of conductor have been tested, unwound, insulated and retested to examine any degradation issues. Additionally, it is known that HTS materials are inherently weak in relation to the winding and handling stresses in a manufacturing environment. A system to provide mechanical stabilization to Nb{sub 3}Sn tape through a lamination process has been successfully applied to high temperature superconductors as a method to build a strong, windable composite. The system is described and mechanical and electrical properties of the strengthened tapes are discussed.

  9. Electric-field control of spin-orbit torque in magnetically doped topological insulators

    Science.gov (United States)

    Fan, Yabin; Shao, Qiming; Kou, Xufeng; Upadhyaya, Pramey; Wang, Kang

    Recent advances of spin-orbit torques (SOTs) generated by topological insulators (TIs) have drawn increasing interest to the spin-momentum locking feature of TIs' surface states, which can potentially provide a very efficient means to generate SOTs for spintronic applications. In this presentation, we will show the magnetization switching through current-induced giant SOT in both TI/Cr-doped TI bilayer and uniformly Cr-doped TI films In particular, we show that the current-induced SOT has significant contribution from the spin-momentum locked surface states of TIs. We find that the spin torque efficiency is in general three orders of magnitude larger than those reported in heavy metal/ferromagnetic heterostructures. In the second part, we will present the electric-field control of the giant SOT in magnetically doped TIs, which suggests promising gate-controlled spin-torque device applications. The giant SOT and efficient current-induced magnetization switching exhibited by the magnetic TIs may lead to innovative spintronic applications such as ultralow power dissipation memory and logic devices. We acknowledge the supports from DARPA, FAME, SHINES and ARO programs.

  10. Cooling of electrically insulated high voltage electrodes down to 30 mK: Dynamic measurements

    CERN Document Server

    Eisel, T; Burghart, G; Feigl, S; Haug, F; Koettig, T

    2011-01-01

    AEgIS [1] is an antimatter experiment, using high voltage electrodes at 100 mK. Two possible principles to cool these electrodes with a dilution refrigerator are investigated: the Rod and the Sandwich. Both designs are described in detail in [2]. The Sandwich design is discussed in the present work. It consists of an electrically insulating sapphire plate covered with indium on both sides. Dynamic measurements are performed in order to estimate the influence of time depending heat loads on different Sandwich designs. From these data the Sandwich’s thermal diffusivity is derived and compared to previous measurements using a static heat load. The lowest resistivity of the Sandwich is achieved with an indium vapor deposition onto polished sapphire (26 cm2K4/W at 30 mK). The same sandwich shows the best, i.e. highest thermal diffusivity (0.23 mm2/s at 70 mK). However, the results of the static and the dynamic measurements show some interesting and contrary tendencies.

  11. Electrically controlled spin polarization and selection in a topological insulator sandwiched between ferromagnetic electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Junji; Liao, Wenhu, E-mail: whliao2007@aliyun.com; Zhao, Heping [College of Physics, Mechanical and Electrical Engineering, Jishou University, Jishou 416000 (China); Zhou, Guanghui [Department of Physics and Key Laboratory for Low-Dimensional Quantum Structures and Manipulation (Ministry of Education), Hunan Normal University, Changsha 410081 (China)

    2014-01-14

    We theoretically investigate the electrically controllable spin polarization and selective efficiency of the edge state Dirac electron in a two-dimensional topological insulator (TI) sandwiched between ferromagnetic (FM) electrodes by using the method of Keldysh nonequilibrium Green's function. A nearly full spin polarization of the topological edge state with giant inversion of ∼80% is observed, which is much higher than the value previously reported. Moreover, the selective efficiency for spin-up electrons under the modulation of the parallel configuration of FM electrodes has been demonstrated to be larger than 95% for the first time, while that for spin-down electrons in the antiparallel case is higher than 90% in a wide energy range, owing to the inter-edge spin tunneling induced backscattering and spin dephasing effect. The obtained results may provide a deeper understanding of the TI edge states and a valuable guidance to design spin switch and filter with high on-off speed and selective efficiency based on TIs.

  12. A new experimental approach for characterizing the internal trapped charge and electric field build up in ground-coated insulators during their e sup - irradiation

    CERN Document Server

    Jbara, O; Belhaj, M; Cazaux, J; Rau, E I; Filippov, M; Andrianov, M V

    2002-01-01

    An original method is proposed to investigate the dynamical trapping properties of bulk insulators during their irradiation by keV electrons when they are coated with a grounded metallic film. This method is based on the measurement of the displacement current and it allows to evaluate time constants for charging and discharging the dielectric as well as to evaluate the electric field build up and trapped charge density below the coating. This method is illustrated by the estimate of the charging and discharging time constants in e sup - irradiated PMMA and the estimate of the magnitude of the electric field which drives the migration of the mobile ions in e sup - irradiated glasses.

  13. A Facile Approach to Evaluate Thermal Insulation Performance of Paper Cups

    OpenAIRE

    Yudi Kuang; Gang Chen; Zhiqiang Fang

    2015-01-01

    Paper cups are ubiquitous in daily life for serving water, soup, coffee, tea, and milk due to their convenience, biodegradability, recyclability, and sustainability. The thermal insulation performance of paper cups is of significance because they are used to supply hot food or drinks. Using an effective thermal conductivity to accurately evaluate the thermal insulation performance of paper cups is complex due to the inclusion of complicated components and a multilayer structure. Moreover, an ...

  14. Density-Polarization Functional Theory of the Response of a Periodic Insulating Solid to an Electric Field

    Science.gov (United States)

    Gonze, X.; Ghosez, Ph.; Godby, R. W.

    1995-05-01

    The response of an infinite, periodic, insulating solid to an infinitesimally small electric field is investigated in the framework of density functional theory. We find that the applied perturbing potential is not a unique functional of the periodic density change; it depends also on the change in the macroscopic polarization. Moreover, the dependence of the exchange-correlation energy on polarization induces an exchange-correlation electric field. These effects are exhibited for a model semiconductor. We also show that the scissor-operator technique is an approximate way of bypassing this polarization dependence.

  15. Thermal and electrical properties of thermal-grease-insulated REBCO superconducting coils with respect to winding tension

    Science.gov (United States)

    Song, Jung-Bin; Choi, Yoon Hyuck; Yang, Dong Gyu; Kim, Young-Gyun; Kim, Seong-Gyeom; Choi, Yeon Suk; Lee, Haigun

    2017-09-01

    This study investigates the thermal and electrical characteristics of a silicon-based grease insulation (GI) GdBCO coil with respect to the winding tension through charge, sudden discharge, and over-current tests. Charge and sudden discharge test results demonstrate that the charging/discharging delay time increases as the winding tension increases; this is because the characteristic resistance of the coil decreases due to the reduced contact resistance. The over-current test results confirm that the thermal/electrical stabilities of the GI coil are considerably enhanced with an increased winding tension resulting from improved thermal contact and the decrease in the electrical contact resistance between the turn-to-turn layers of the coil. Thus, as the winding tension increases, the charging/discharging rates decrease whereas the thermal/electrical stabilities improve. Overall, selecting the appropriate winding tension for a GI coil is critical for achieving thermal/electrical stabilities, as well as ameliorating the charging/discharging delay phenomenon generally observed in a no-insulation coil.

  16. A Facile Approach to Evaluate Thermal Insulation Performance of Paper Cups

    Directory of Open Access Journals (Sweden)

    Yudi Kuang

    2015-01-01

    Full Text Available Paper cups are ubiquitous in daily life for serving water, soup, coffee, tea, and milk due to their convenience, biodegradability, recyclability, and sustainability. The thermal insulation performance of paper cups is of significance because they are used to supply hot food or drinks. Using an effective thermal conductivity to accurately evaluate the thermal insulation performance of paper cups is complex due to the inclusion of complicated components and a multilayer structure. Moreover, an effective thermal conductivity is unsuitable for evaluating thermal insulation performance of paper cups in the case of fluctuating temperature. In this work, we propose a facile approach to precisely analyze the thermal insulation performance of paper cups in a particular range of temperature by using an evaluation model based on the MISO (Multiple-Input Single-Output technical theory, which includes a characterization parameter (temperature factor and a measurement apparatus. A series of experiments was conducted according to this evaluation model, and the results show that this evaluation model enables accurate characterization of the thermal insulation performance of paper cups and provides an efficient theoretical basis for selecting paper materials for paper cups.

  17. Evaluation of Electrical Characteristics of Protective Equipment - a Prerequisite for Ensuring Safety and Health of Workers at Work

    Science.gov (United States)

    Buică, G.; Beiu, C.; Antonov, A.; Dobra, R.; Păsculescu, D.

    2017-06-01

    The protecting electrical equipment in use are subject to various factors generated by the use, maintenance, storage and working environment, which may change the characteristics of protection against electric shock. The study presents the results of research on the behaviour over time of protective characteristics of insulating covers of material of work equipment in use, in order to determine the type and periodicity of safety tests. There were tested and evaluated safety equipment with plastic and insulating rubber covers used in operations of verifying functionality, safety and maintenance of machinery used in manufacturing industries and specific services from electric, energy and food sector.

  18. Objective and subjective evaluation of façade sound insulation

    DEFF Research Database (Denmark)

    Ordoñez, Rodrigo Pizarro; Visentin, Chiara; Markovic, Milos

    2013-01-01

    Façade insulation of several different construction types were subjectively evaluated using two psychoacoustic methods: paired comparisons using a two alternative forced choice (2-AFC) paradigm and direct scaling using a visual analogue scale (VAS). The stimuli used in the evaluations were obtained...... by filtering recordings of traffic noise with the frequency response of sound insulation measurements. The measurements were performed in typical Italian buildings in accordance with the ISO 140-5 standard. The objectives of the present paper are to compare the subjective evaluations obtained with the two...

  19. Methodology for Evaluating Raw Material Changes to RSRM Elastomeric Insulation Materials

    Science.gov (United States)

    Mildenhall, Scott D.; McCool, Alex (Technical Monitor)

    2001-01-01

    The Reusable Solid Rocket Motor (RSRM) uses asbestos and silicon dioxide filled acrylonitrile butadiene rubber (AS-NBR) as the primary internal insulation to protect the case from heat. During the course of the RSRM Program, several changes have been made to the raw materials and processing of the AS-NBR elastomeric insulation material. These changes have been primarily caused by raw materials becoming obsolete. In addition, some process changes have been implemented that were deemed necessary to improve the quality and consistency of the AS-NBR insulation material. Each change has been evaluated using unique test efforts customized to determine the potential impacts of the specific raw material or process change. Following the evaluations, the various raw material and process changes were successfully implemented with no detectable effect on the performance of the AS-NBR insulation. This paper will discuss some of the raw material and process changes evaluated, the methodology used in designing the unique test plans, and the general evaluation results. A summary of the change history of RSRM AS-NBR internal insulation is also presented.

  20. Voltage- and current-activated metal–insulator transition in VO2-based electrical switches: a lifetime operation analysis

    Directory of Open Access Journals (Sweden)

    Aurelian Crunteanu, Julien Givernaud, Jonathan Leroy, David Mardivirin, Corinne Champeaux, Jean-Christophe Orlianges, Alain Catherinot and Pierre Blondy

    2010-01-01

    Full Text Available Vanadium dioxide is an intensively studied material that undergoes a temperature-induced metal–insulator phase transition accompanied by a large change in electrical resistivity. Electrical switches based on this material show promising properties in terms of speed and broadband operation. The exploration of the failure behavior and reliability of such devices is very important in view of their integration in practical electronic circuits. We performed systematic lifetime investigations of two-terminal switches based on the electrical activation of the metal–insulator transition in VO2 thin films. The devices were integrated in coplanar microwave waveguides (CPWs in series configuration. We detected the evolution of a 10 GHz microwave signal transmitted through the CPW, modulated by the activation of the VO2 switches in both voltage- and current-controlled modes. We demonstrated enhanced lifetime operation of current-controlled VO2-based switching (more than 260 million cycles without failure compared with the voltage-activated mode (breakdown at around 16 million activation cycles. The evolution of the electrical self-oscillations of a VO2-based switch induced in the current-operated mode is a subtle indicator of the material properties modification and can be used to monitor its behavior under various external stresses in sensor applications.

  1. Investigation of thermal and electrical stabilities of a GdBCO coil using grease as an insulation material for practical superconducting applications.

    Science.gov (United States)

    Kang, D H; Kim, K L; Kim, Y G; Park, Y J; Kim, W J; Kim, S H; Lee, H G

    2014-09-01

    This paper presents the effects of thermal grease on the electrical and thermal characteristics of GdBCO pancake coils, observed through charge-discharge, sudden discharge, over-current, and thermal quench testing. In charge-discharge and sudden discharge tests, a coil using thermal grease as an insulation material demonstrated faster charging/discharging rates compared to a coil without turn-to-turn insulation. In the case of over-current tests, the coil using thermal grease exhibited the highest electrical stability. Furthermore, thermal quench testing showed the coil employing thermal grease to possess superior thermal characteristics, with rapid cooling and low temperature rise. Overall, the use of thermal grease as an insulation material may be a potential solution to the problems observed with the existing insulation materials, possessing fast charging/discharging rates with superior thermal and electrical stabilities.

  2. Evaluation of airborne and impact sound insulation by means of loudness

    DEFF Research Database (Denmark)

    Rindel, Jens Holger

    2006-01-01

    The currently used evaluation methods in ISO 717 have the possibility of including spectrum adaptation terms, which may have the advantage of improved correlation with subjective evaluation of the sound insulation. However, the current method is complicated, and it is open for many variations...

  3. Measurements of Electrical and Electron Emission Properties of Highly Insulating Materials

    Science.gov (United States)

    Dennison, J. R.; Brunson, Jerilyn; Hoffman, Ryan; Abbott, Jonathon; Thomson, Clint; Sim, Alec

    2005-01-01

    Highly insulating materials often acquire significant charges when subjected to fluxes of electrons, ions, or photons. This charge can significantly modify the materials properties of the materials and have profound effects on the functionality of the materials in a variety of applications. These include charging of spacecraft materials due to interactions with the severe space environment, enhanced contamination due to charging in Lunar of Martian environments, high power arching of cables and sources, modification of tethers and ion thrusters for propulsion, and scanning electron microscopy, to name but a few examples. This paper describes new techniques and measurements of the electron emission properties and resistivity of highly insulating materials. Electron yields are a measure of the number of electrons emitted from a material per incident particle (electron, ion or photon). Electron yields depend on incident species, energy and angle, and on the material. They determine the net charge acquired by a material subject to a give incident flu. New pulsed-beam techniques will be described that allow accurate measurement of the yields for uncharged insulators and measurements of how the yields are modified as charge builds up in the insulator. A key parameter in modeling charge dissipation is the resistivity of insulating materials. This determines how charge will accumulate and redistribute across an insulator, as well as the time scale for charge transport and dissipation. Comparison of new long term constant-voltage methods and charge storage methods for measuring resistivity of highly insulating materials will be compared to more commonly used, but less accurate methods.

  4. Effects of additional oxidation after Ge condensation on electrical properties of germanium-on-insulator p-channel MOSFETs

    Science.gov (United States)

    Suh, Junkyo; Nakane, Ryosho; Taoka, Noriyuki; Takenaka, Mitsuru; Takagi, Shinichi

    2016-03-01

    This paper discusses the effects of additional oxidation after Ge condensation on electrical characteristics of fully depleted germanium-on-insulator (FDGOI) p-channel MOSFETs. We highlight the passivation of the back interface of GOI layers by the additional oxidation. Moreover, the electrical characteristics of the fabricated GOI pMOSFETs were systematically analyzed with varying the additional oxidation time and resulting compressive strain. It is found that 12-nm-thick GOI pMOSFETs with 0.94 % compressive strain were realized without any additional oxidation by utilizing strained silicon-on-insulator (sSOI), showing the drive current over twice as high as that of unstrained Ge pMOSFETs. However, the devices exhibit large positive threshold voltage (Vth) shifts, large subthreshold swing (SS), and high off-state current (Ioff), attributable to the poor MOS interfaces with buried oxides (BOX). This back channel MOS interface can be effectively passivated without significant growth of the BOX thickness by additional oxidation, leading to the restoration of the Vth shifts, improved SS, and dramatic reduction of Ioff. It is also found that the improvement of the back interface (Ge/BOX) and the strain relaxation occur simultaneously by the additional oxidation, which is corroborated by Raman spectroscopy, transmission electron microscopy (TEM), and the electrical characterization of GOI pMOSFETs. As a result, a possible physical model to explain the observed phenomena was proposed.

  5. Some Observations on the Dielectric Breakdown and the Importance of Cavities in Insulating Materials used for Cables and Electrical Machines

    Directory of Open Access Journals (Sweden)

    KARLIS, A. D.

    2011-05-01

    Full Text Available Partial discharges (PD contribute greatly to the ageing and the breakdown of solid insulating materials. In the present paper, some conductivity measurements are performed relating the conductivity of inner walls of an enclosed cavity to the behaviour of PD in the case of polyethylene and of epoxy resin. The temporary decrease of the PD magnitude is explained in terms of the increase of the cavity inner wall conductivity. The PD behaviour is studied in epoxy resin samples and is explained with the aid of Pedersen's model. Scanning Electron Microscope (SEM photographs indicate the sort of damage suffered by the cavity walls under electrical stress.

  6. Numerical Modeling of the Electric Field and the Potential Distributions in Heterogeneous Cavities inside XLPE Power Cable Insulation

    Directory of Open Access Journals (Sweden)

    KHOUILDI Emna

    2016-10-01

    Full Text Available The XLPE power cable is easily affected by heterogeneous cavities: air void cavity, vented and bow-tie water trees. In this paper, we present a numerical modeling of this cable. A number of simulations are realized in order to analyze the influence of heterogeneous cavities and the influence of their positions and sizes on the electric field distribution, the potential distribution and the degradation of the XLPE insulation. The models are implemented with the finite element method based on the software package COMSOL Multiphysics.

  7. Electric preheating - a new method for laying pre-insulated district heating pipes. District heating schemes on-line faster

    Energy Technology Data Exchange (ETDEWEB)

    Lambertsen, E.; Pedersen, H.N.

    1990-01-01

    i.c.moeller a/s of Fredericia, Denmark, is one of the world's leading manufacturers of pre-insulated pipe systems. The company, a member of the ABB Group, has refined district heating pipeline design to a degree where heat losses can be neglected over distances of 100 km and more. Pipe installation is also undergoing continuing improvement at i.c.moeller, which has developed a method of electric preheating that makes it easier to prestress friction-locked pipe systems. This method has also proved successful for large-diameter pipes. (orig.).

  8. Electric multipole moments, topological multipole moment pumping, and chiral hinge states in crystalline insulators

    Science.gov (United States)

    Benalcazar, Wladimir A.; Bernevig, B. Andrei; Hughes, Taylor L.

    2017-12-01

    We extend the theory of dipole moments in crystalline insulators to higher multipole moments. As first formulated in Benalcazar et al. [Science 357, 61 (2017), 10.1126/science.aah6442], we show that bulk quadrupole and octupole moments can be realized in crystalline insulators. In this paper, we expand in great detail the theory presented previously [Benalcazar et al., Science 357, 61 (2017), 10.1126/science.aah6442] and extend it to cover associated topological pumping phenomena, and a class of three-dimensional (3D) insulator with chiral hinge states. We start by deriving the boundary properties of continuous classical dielectrics hosting only bulk dipole, quadrupole, or octupole moments. In quantum mechanical crystalline insulators, these higher multipole bulk moments manifest themselves by the presence of boundary-localized moments of lower dimension, in exact correspondence with the electromagnetic theory of classical continuous dielectrics. In the presence of certain symmetries, these moments are quantized, and their boundary signatures are fractionalized. These multipole moments then correspond to new symmetry-protected topological phases. The topological structure of these phases is described by "nested" Wilson loops, which we define. These Wilson loops reflect the bulk-boundary correspondence in a way that makes evident a hierarchical classification of the multipole moments. Just as a varying dipole generates charge pumping, a varying quadrupole generates dipole pumping, and a varying octupole generates quadrupole pumping. For nontrivial adiabatic cycles, the transport of these moments is quantized. An analysis of these interconnected phenomena leads to the conclusion that a new kind of Chern-type insulator exists, which has chiral, hinge-localized modes in 3D. We provide the minimal models for the quantized multipole moments, the nontrivial pumping processes, and the hinge Chern insulator, and describe the topological invariants that protect them.

  9. Insulated Pressure Vessels for Vehicular Hydrogen Storage: Analysis and Performance Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, S M; Martinez-Frias, J; Garcia-Villazana, O; Espinosa-Loza, F

    2001-06-26

    Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LH{sub 2}) or ambient-temperature compressed hydrogen (CH{sub 2}). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (fuel flexibility, lower energy requirement for hydrogen liquefaction and reduced evaporative losses). The work described here is directed at verifying that commercially available pressure vessels can be safely used to store liquid hydrogen. The use of commercially available pressure vessels significantly reduces the cost and complexity of the insulated pressure vessel development effort. This paper describes a series of tests that have been done with aluminum-lined, fiber-wrapped vessels to evaluate the damage caused by low temperature operation. All analysis and experiments to date indicate that no significant damage has resulted. Required future tests are described that will prove that no technical barriers exist to the safe use of aluminum-fiber vessels at cryogenic temperatures. Future activities also include a demonstration project in which the insulated pressure vessels will be installed and tested on two vehicles. A draft standard will also be generated for obtaining certification for insulated pressure vessels.

  10. Evaluation of Structure Influence on Thermal Conductivity of Thermal Insulating Materials from Renewable Resources

    Directory of Open Access Journals (Sweden)

    Jolanta VĖJELIENĖ

    2011-07-01

    Full Text Available The development of new thermal insulation materials needs to evaluate properties and structure of raw material, technological factors that make influence on the thermal conductivity of material. One of the most promising raw materials for production of insulation material is straw. The use of natural fibres in insulation is closely linked to the ecological building sector, where selection of materials is based on factors including recyclable, renewable raw materials and low resource production techniques In current work results of research on structure and thermal conductivity of renewable resources for production thermal insulating materials are presented. Due to the high abundance of renewable resources and a good its structure as raw material for thermal insulation materials barley straw, reeds, cattails and bent grass stalks are used. Macro- and micro structure analysis of these substances is performed. Straw bales of these materials are used for determining thermal conductivity. It was found that the macrostructure has the greatest effect on thermal conductivity of materials. Thermal conductivity of material is determined by the formation of a bale due to the large amount of pores among the stalks of the plant, inside the stalk and inside the stalk wall.http://dx.doi.org/10.5755/j01.ms.17.2.494

  11. Evaluation of transformer insulating oil quality using NIR, fluorescence, and NMR spectroscopic data fusion.

    Science.gov (United States)

    Godinho, Mariana S; Blanco, Marcos R; Gambarra Neto, Francisco F; Lião, Luciano M; Sena, Marcelo M; Tauler, Romà; de Oliveira, Anselmo E

    2014-11-01

    Power transformers are essential components in electrical energy distribution. One of their most important parts is the insulation system, consisting of Kraft paper immersed in insulating oil. Interfacial tension and color are major parameters used for assessing oil quality and the system׳s degradation. This work proposes the use of near infrared (NIR), molecular fluorescence, and (1)H nuclear magnetic resonance (NMR) spectroscopy methods combined with chemometric multivariate calibration methods (Partial Least Squares - PLS) to predict interfacial tension and color in insulating mineral oil samples. Interfacial tension and color were also determined using tensiometry and colorimetry as standard reference methods, respectively. The best PLS model was obtained when NIR, fluorescence, and NMR data were combined (data fusion), demonstrating synergy among them. An optimal PLS model was calculated using the selected group of variables according to their importance on PLS projections (VIP). The root mean square errors of prediction (RMSEP) values of 2.9 mN m(-1) and 0.3 were estimated for interfacial tension and color, respectively. Mean relative standard deviations of 1.5% for interfacial tension and 6% for color were registered, meeting quality control requirements set by electrical energy companies. The methods proposed in this work are rapid and simple, showing great advantages over traditional approaches, which are slow and environmentally unfriendly due to chemical waste generation. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Development of High Temperature Type Vacuum Insulation Panel using Soluble Polyimide and Characteristic Evaluation

    Science.gov (United States)

    Araki, Kuninari; Kamoto, Daigorou; Matsuoka, Shin-Ichi

    The utilization is expected from the high-insulated characteristic as a tool for energy saving also in the high temperature insulation fields as in vacuum insulation panels (VIP) in the future. For high temperature, the material composition and process of VIP were reviewed, the SUS foil was adopted as packaging material, and soluble polyimide was developed as the thermo compression bonding material for high temperature VIP at 150°C. To lower the glass-transition temperature (Tg) under 200°C, we elaborated the new soluble polyimide using aliphatic diamine copolymer, and controlled Tg to about 176°C. By making from trial VIP and evaluations, it was possible to be maintain high performance concerning the coefficient of thermal conductivity [λ<0.008 W/(m·K) at 150°C].

  13. An indirect method to measure the electric charge deposited on insulators during PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dinator, M.I.; Cancino, S.A.; Miranda, P.A. [Departamento de Fisica, Facultad de Ciencias, Universidad de Chile, Las Palmeras 3425, Nunoa, Santiago (Chile); Morales, J.R. [Departamento de Fisica, Facultad de Ciencias, Universidad de Chile, Las Palmeras 3425, Nunoa, Santiago (Chile)], E-mail: rmorales@uchile.cl; Seelenfreund, A. [Universidad Academia de Humanismo Cristiano, Condell 343, Providencia, Santiago (Chile)

    2007-10-15

    Total charge deposited by a proton beam in an insulator during PIXE analysis has been indirectly determined using a Mylar film coated with cobalt. Elemental concentrations in the samples, pieces of volcanic glass, were obtained and compared to concentrations determined by ICP OES on the same samples. The strong agreement between these results shows the accuracy of the charge determined by this method.

  14. Resistance noise spectroscopy across the thermally and electrically driven metal-insulator transitions in VO2 nanobeams

    Science.gov (United States)

    Alsaqqa, Ali; Kilcoyne, Colin; Singh, Sujay; Horrocks, Gregory; Marley, Peter; Banerjee, Sarbajit; Sambandamurthy, G.

    Vanadium dioxide (VO2) is a strongly correlated material that exhibits a sharp thermally driven metal-insulator transition at Tc ~ 340 K. The transition can also be triggered by a DC voltage in the insulating phase with a threshold (Vth) behavior. The mechanisms behind these transitions are hotly discussed and resistance noise spectroscopy is a suitable tool to delineate different transport mechanisms in correlated systems. We present results from a systematic study of the low frequency (1 mHz noise behavior in VO2 nanobeams across the thermally and electrically driven transitions. In the thermal transition, the power spectral density (PSD) of the resistance noise is unchanged as we approach Tc from 300 K and an abrupt drop in the magnitude is seen above Tc and it remains unchanged till 400 K. However, the noise behavior in the electrically driven case is distinctly different: as the voltage is ramped from zero, the PSD gradually increases by an order of magnitude before reaching Vth and an abrupt increase is seen at Vth. The noise magnitude decreases above Vth, approaching the V = 0 value. The individual roles of percolation, Joule heating and signatures of correlated behavior will be discussed. This work is supported by NSF DMR 0847324.

  15. Evaluation electric bicycles; Evaluation velos electriques

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-10-01

    Leovelo service is the first measure in favor of the bicycle to control the air pollution and to conserve energy. It provides in the city of Clermont-Ferrand (France) a service of bicycle hiring. This document evaluates the project after two years of operating. It provides a technical evaluation (maintenance, equipment, financing) and also the socio-economic impacts. (A.L.B.)

  16. Effect of thickness of insulation coating on temperature of electrically exploded tungsten wires in vacuum

    Science.gov (United States)

    Shi, Huantong; Zou, Xiaobing; Wang, Xinxin

    2017-07-01

    This paper reports an interesting observation of great differences in the temperature of exploded wires with insulation coating of different thicknesses. Two kinds of polyimide-coated tungsten wires were used with the same conductive diameter 12.5 μm but a different thickness of coating, 0.75-2.25 μm and 2.25-4.25 μm, respectively. The specific energy reconstructed from the current and voltage signals was quite close for the tested wires. However, the exploding scenario, obtained from Mach-Zehnder interferograms, showed great differences: a neutral outer-layer was observed around the thick-coated wire, which was absent for the thin-coated wire; and the calculated electron density and local thermal equilibrium temperature were much higher for thick-coated wires. The heat-preserving neutral layer formed by the decomposition of the insulation was supposed to be the cause of this phenomenon.

  17. Underground electrical power transmission lines in coastal areas: Insulation and installation. Problemi connessi con posa e esercizio di cavi elettrici di potenza in ambiente lagunare

    Energy Technology Data Exchange (ETDEWEB)

    Bisiach, L.; Cerretti, A.; Cocchiglia, A. (Ente Nazionale per l' Energia Elettrica, Venice (Italy))

    1992-12-01

    The coastal area of Venice, crossed by an intricate network of salt water canals, presents particular problems for engineers planning the installation of underground power transmission lines. This paper traces the development, by ENEL (the Italian National Electricity Board), of suitable electrical insulation specifications to counter the destructive physical-chemical effects on power cables of highly corrosive coastal lagoon environments. Cable trench excavation, cable installation and trench back-filling methods are described specifying suitable depths, choice and layering of materials designed to adequately protect buried high and medium voltage lines crossing navigable canals. Reference is made to the relative Italian normatives governing power cable insulation and installation.

  18. Flame spread over electrical wire with AC electric fields: Internal circulation, fuel vapor-jet, spread rate acceleration, and molten insulator dripping

    KAUST Repository

    Lim, Seungjae

    2015-04-01

    The effect of electric field on the characteristics of flame spread along a polyethylene (PE) insulated electrical wire was investigated experimentally by varying the AC frequency and voltage applied to the wire. The results showed that the flame spread rate was accelerated due to the convergence of electric flux near the end of wire, having three distinct regimes depending on applied voltage. In each regime, several subregimes could be identified depending on AC frequency. Flame shape (height and width) and slanted direction of the spreading flame were influenced differently. Fuel-vapor jets were ejected from the molten PE surface even for the baseline case without the application of an electric field; this could be attributed to the bursting of fuel vapor bubbles generated from internal boiling at the molten PE surface. An internal circulation of molten-PE was also observed as a result of non-uniform heating by the spreading flame. In the high voltage regime with a high AC frequency, excessive dripping of molten PE led to flame extinction.

  19. Contribution of ethylenetetrafluoroethylene (ETFE) insulation to the electrical performance of Riata® silicone leads having externalized conductors.

    Science.gov (United States)

    Fischer, Avi; Klehn, Russell

    2013-08-01

    The insulation of St. Jude Medical Riata® leads contains a polytetrafluoroethylene (PTFE) liner, silicone tubing, and ethylenetetrafluoroethylene (ETFE) coating on individual cable conductors. ETFE has sufficient dielectric strength to assure electrical function. This investigation intended to analyze performance of leads with and without externalized conductors and with intact and breached ETFE. Testing was performed on ETFE-coated conductors to determine their ability to deliver high-voltage therapy. Tests were performed on samples under different conditions and current leakage was measured. A high-voltage test and a cyclic pulse test were performed, and the effect of lead modifications on the potential gradient from a high-voltage shock was used to determine functionality. Measurements from modified Riata® leads were compared with a control lead with all insulation and conducting elements intact. Current leakage for all conditions tested, was within the acceptance criteria for the high-voltage test and the cyclic pulse test. In conductors that underwent cyclic testing, the highest value of current leakage was within the limit of acceptability for both phases of the test. Testing of leads with externalized conductors and breached ETFE showed similar potential gradients compared with a control lead. Testing of ETFE-coated conductors following multiple preconditioning steps showed that ETFE serves as a redundant layer of insulation. In the event that the ETFE coating is breached, the potential gradient seen resulting from a high-voltage defibrillation shock was similar to a lead with no breach to the ETFE, even after 100 shocks.

  20. Role of geometric parameters in electrical measurements of insulating thin films deposited on a conductive substrate

    Science.gov (United States)

    Kumar, S.; Gerhardt, R. A.

    2012-03-01

    The effects of film thickness, electrode size and substrate thickness on the impedance parameters of alternating frequency dielectric measurements of insulating thin films deposited on conductive substrates were studied through parametric finite-element simulations. The quasi-static forms of Maxwell's electromagnetic equations in a time harmonic mode were solved using COMSOL Multiphysics® for several types of 2D models (linear and axisymmetric). The full 2D model deals with a configuration in which the impedance is measured between two surface electrodes on top of a film deposited on a conductive substrate. For the simplified 2D models, the conductive substrate is ignored and the two electrodes are placed on the top and bottom of the film. By comparing the full model and the simplified models, approximations and generalizations are deduced. For highly insulating films, such as the case of insulating SiO2 films on a conducting Si substrate, even the simplified models predict accurate capacitance values at all frequencies. However, the edge effects on the capacitance are found to be significant when the film thickness increases and/or the top electrode contact size decreases. The thickness of the substrate affects predominantly the resistive components of the dielectric response while having no significant effect on the capacitive components. Changing the electrode contact size or the film thickness determines the specific values of the measured resistance or capacitance while the material time constant remains the same, and thus this affects the frequency dependence that is able to be detected. This work highlights the importance of keeping in mind the film thickness and electrode contact size for the correct interpretation of the measured dielectric properties of micro/nanoscale structures that are often investigated using nanoscale capacitance measurements.

  1. Metal-insulator transition in tin doped indium oxide (ITO) thin films: Quantum correction to the electrical conductivity

    Science.gov (United States)

    Kaushik, Deepak Kumar; Kumar, K. Uday; Subrahmanyam, A.

    2017-01-01

    Tin doped indium oxide (ITO) thin films are being used extensively as transparent conductors in several applications. In the present communication, we report the electrical transport in DC magnetron sputtered ITO thin films (prepared at 300 K and subsequently annealed at 673 K in vacuum for 60 minutes) in low temperatures (25-300 K). The low temperature Hall effect and resistivity measurements reveal that the ITO thin films are moderately dis-ordered (kFl˜1; kF is the Fermi wave vector and l is the electron mean free path) and degenerate semiconductors. The transport of charge carriers (electrons) in these disordered ITO thin films takes place via the de-localized states. The disorder effects lead to the well-known `metal-insulator transition' (MIT) which is observed at 110 K in these ITO thin films. The MIT in ITO thin films is explained by the quantum correction to the conductivity (QCC); this approach is based on the inclusion of quantum-mechanical interference effects in Boltzmann's expression of the conductivity of the disordered systems. The insulating behaviour observed in ITO thin films below the MIT temperature is attributed to the combined effect of the weak localization and the electron-electron interactions.

  2. Metal-insulator transition in tin doped indium oxide (ITO thin films: Quantum correction to the electrical conductivity

    Directory of Open Access Journals (Sweden)

    Deepak Kumar Kaushik

    2017-01-01

    Full Text Available Tin doped indium oxide (ITO thin films are being used extensively as transparent conductors in several applications. In the present communication, we report the electrical transport in DC magnetron sputtered ITO thin films (prepared at 300 K and subsequently annealed at 673 K in vacuum for 60 minutes in low temperatures (25-300 K. The low temperature Hall effect and resistivity measurements reveal that the ITO thin films are moderately dis-ordered (kFl∼1; kF is the Fermi wave vector and l is the electron mean free path and degenerate semiconductors. The transport of charge carriers (electrons in these disordered ITO thin films takes place via the de-localized states. The disorder effects lead to the well-known ‘metal-insulator transition’ (MIT which is observed at 110 K in these ITO thin films. The MIT in ITO thin films is explained by the quantum correction to the conductivity (QCC; this approach is based on the inclusion of quantum-mechanical interference effects in Boltzmann’s expression of the conductivity of the disordered systems. The insulating behaviour observed in ITO thin films below the MIT temperature is attributed to the combined effect of the weak localization and the electron-electron interactions.

  3. Low temperature plasma enhanced chemical vapor deposition of thin films combining mechanical stiffness, electrical insulation, and homogeneity in microcavities

    Science.gov (United States)

    Peter, S.; Günther, M.; Hauschild, D.; Richter, F.

    2010-08-01

    The deposition of hydrogenated amorphous carbon (a-C:H) as well as hydrogenated amorphous silicon carbonitride (SiCN:H) films was investigated in view of a simultaneous realization of a minimum Young's modulus (>70 GPa), a high electrical insulation (≥1 MV/cm), a low permittivity and the uniform coverage of microcavities with submillimeter dimensions. For the a-C:H deposition the precursors methane (CH4) and acetylene (C2H2) were used, while SiCN:H films were deposited from mixtures of trimethylsilane [SiH(CH3)3] with nitrogen and argon. To realize the deposition of micrometer thick films with the aforementioned complex requirements at substrate temperatures ≤200 °C, several plasma enhanced chemical vapor deposition methods were investigated: the capacitively coupled rf discharge and the microwave electron cyclotron resonance (ECR) plasma, combined with two types of pulsed substrate bias. SiCN:H films deposited at about 1 Pa from ECR plasmas with pulsed high-voltage bias best met the requirements. Pulsed biasing with pulse periods of about 1 μs and amplitudes of about -2 kV was found to be most advantageous for the conformal low temperature coating of the microtrenches, thereby ensuring the required mechanical and insulating film properties.

  4. Microwave and Millimeter Wave Nondestructive Evaluation of the Space Shuttle External Tank Insulating Foam

    Science.gov (United States)

    Shrestha, S.; Kharkovsky, S.; Zoughi, R.; Hepburn, F

    2005-01-01

    The Space Shuttle Columbia s catastrophic failure has been attributed to a piece of external fuel tank insulating SOFI (Spray On Foam Insulation) foam striking the leading edge of the left wing of the orbiter causing significant damage to some of the protecting heat tiles. The accident emphasizes the growing need to develop effective, robust and life-cycle oriented methods of nondestructive testing and evaluation (NDT&E) of complex conductor-backed insulating foam and protective acreage heat tiles used in the space shuttle fleet and in future multi-launch space vehicles. The insulating SOFI foam is constructed from closed-cell foam. In the microwave regime this foam is in the family of low permittivity and low loss dielectric materials. Near-field microwave and millimeter wave NDT methods were one of the techniques chosen for this purpose. To this end several flat and thick SOFI foam panels, two structurally complex panels similar to the external fuel tank and a "blind" panel were used in this investigation. Several anomalies such as voids and disbonds were embedded in these panels at various locations. The location and properties of the embedded anomalies in the "blind" panel were not disclosed to the investigating team prior to the investigation. Three frequency bands were used in this investigation covering a frequency range of 8-75 GHz. Moreover, the influence of signal polarization was also investigated. Overall the results of this investigation were very promising for detecting the presence of anomalies in different panels covered with relatively thick insulating SOFI foam. Different types of anomalies were detected in foam up to 9 in thick. Many of the anomalies in the more complex panels were also detected. When investigating the blind panel no false positives were detected. Anomalies in between and underneath bolt heads were not easily detected. This paper presents the results of this investigation along with a discussion of the capabilities of the method

  5. EVALUATION OF INDUCTANCE WITH ELECTRICAL WIRES

    Directory of Open Access Journals (Sweden)

    V. Kudry

    2016-08-01

    Full Text Available In this paper proved the possibility of developing passive electronic inductive elements based replace metal wire that is wound inductor, the wire is made of electret. The relative permeability of the electret S  10 000, several orders of magnitude greater than the permeability of conventional insulation materials, i < 10, resulting current in the wire acquires properties bias current. The essence of innovation is to replace the source of of magnetic induction flow that pervades the core of the coil. According to the theory of electrodynamics, current bias, in contrast to conduction current, generated no movement of charge along the wire, but the change of the charge in the local volume.Equivalence bias current and conduction current is manifested in the possibility of forming a magnetic field. The flow through magnetic induction coil core regardless of the current it generates, creates voltage at its ends.The paper also shows the numeric characteristics that determine the effective frequency range, specified the reason why electric a wire with і < 10 can not generate magnetic flux through the core and serve as a passive reactive component.

  6. Consideration in GIS insulation coordination

    Energy Technology Data Exchange (ETDEWEB)

    Bargigia, A.

    1990-01-01

    Analysis of electrical system failures reveals that many are caused by insulation breakdowns due to overvoltages. The problem of insulation co-ordination is then one of the most important aspects in the design of an electrical system. Insulation co-ordination of gas-insulated sub-stations (GIS) has recently received much attention especially due to a large diffusion of this insulation technique. In this review of GIS insulation co-ordination, attention is given to the impact on the insulation co-ordination strategy of the metal-clad disconnector performance during capacity current switching operations.

  7. Aligned Graphene Oxide Nanofillers: An Approach to Prepare Highly Thermally Conductive and Electrically Insulative Transparent Polymer Composites

    Directory of Open Access Journals (Sweden)

    Genlian Lin

    2015-01-01

    Full Text Available Graphene oxide (GO/polyvinyl alcohol composites with extremely high in-plane thermal conductivities are prepared by a simple tape casting process using water as process solvent. The in-plane thermal conductivity of the composite can reach 17.61 W/mK at only 0.1 wt% GO loading, which is close to that of fully dense alumina. The excellent thermal conducting ability, the unique two-dimensional morphology, and the all-wet handling of the GO fillers as well as the high orientation of the fillers in the polymer matrix all contribute to the high thermal conductivities achieved. Meanwhile, the composites show good electrical insulation property and decent transparency.

  8. Localization of Electrical Insulation Failures in Superconducting Collared Coils by Analysis of the Distortion of a Pulsed Magnetic Field

    CERN Document Server

    Komorowski, P A

    2000-01-01

    The localization of possible electrical faults in superconducting accelerator magnets may, in most cases, be a complex, expensive and time-consuming process. In particular, inter-turn short circuits and failures of the ground insulation are well detectable when the magnet is collared, but often disappear after disassembly for repair due to the release of the pre-stress in the coils. The fault localization method presented in this paper is based on the measurement and analysis of the magnetic field generated inside the magnet aperture by a high voltage pulse. The presence of the fault modifies the distribution of the current in the coils and produces a distortion of the magnetic field. The described method aims at locating both the longitudinal and azimuthal position of the fault-affected area. The test method, the transient case FEM models and the implemented experimental set-up are presented and discussed for the LHC dipole models.

  9. Examples of occupational exposure to electric and magnetic fields at 110-kV gas-insulated substations (GISs).

    Science.gov (United States)

    Korpinen, Leena; Pääkkönen, Rauno

    2015-02-01

    The objectives of the study were to present examples of occupational exposure to electric and magnetic fields at gas-insulated substations (GISs) and to analyse the exposure according to the new European Directive 2013/35/EU. The aim was also to describe the details of the measurements of this study at GISs. Electric and magnetic fields were measured (45 measurements in total) at two GISs in the Tampere region of Finland. Inside the GISs, magnetic field values varied from 0.4 to 43.0 µT, and electric fields from 5 to 90 V m(-1). In the cable room of GIS B, the maximum value was 250 µT (very near the cables). The values did not exceed the low or high action levels of the new Directive 2013/35/EU. In conclusion, it can be stated that at 110-kV GISs, workers are not exposed to electromagnetic fields (EMFs) higher than the new European Directive 2013/35/EU. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. A Fast-Acting Diagnostic Algorithm of Insulated Gate Bipolar Transistor Open Circuit Faults for Power Inverters in Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Lei Yu

    2017-04-01

    Full Text Available To improve the diagnostic detection speed in electric vehicles, a novel diagnostic algorithm of insulated gate bipolar transistor (IGBT open circuit faults for power inverters is proposed in this paper. The average of the difference between the actual three-phase current and referential three-phase current values over one electrical period is used as the diagnostic variable. The normalization method based on the amplitude of the d-q axis referential current is applied to the diagnostic variables to improve the response speed of diagnosis, and to avoid the noise and the delay caused by signal acquisition. In the parameter discretization process, the variable parameter moving average method (VPMAM is adopted to solve the variation of the average value over a period with the speed of the motor; hence, the diagnostic reliability of the system is improved. This algorithm is robust, independent of load variations, and has a high resistivity against false alarms. Since only the three-phase current of the motor is utilized for calculations in the time domain, a fast diagnostic detection speed can be achieved, which is significantly essential for real-time control in electric vehicles. The effectiveness of the proposed algorithm is verified by both simulation and experimental results.

  11. Electricity Breakdown Management for Sarawak Energy: Use of Condition-Based Equipment for Detection of Defective Insulator

    Science.gov (United States)

    Tan, J. K.; Abas, N.

    2017-07-01

    Managing electricity breakdown is vital since an outage causes economic losses for customers and the utility companies. However, electricity breakdown is unavoidable due to some internal or external factors beyond our control. Electricity breakdown on overhead lines tend occur more frequently because it is prone to external disturbances such as animal, overgrown vegetation and defective pole top accessories. In Sarawak Energy Berhad (SEB), majority of the network are composed of overhead lines and hence, is more prone to failure. Conventional method of equipment inspection and fault finding are not effective to quickly identify the root cause of failure. SEB has engaged the use of corona discharge camera as condition-based monitoring equipment to carry out condition based inspection on the line in order to diagnose the condition of the lines prior to failure. Experimental testing has been carried out to determine the correlation between the corona discharge count and the level of defect on line insulator. The result shall be tabulated and will be used as reference for future scanning and diagnostic on any defect on the lines.

  12. Electrical properties of germanium-based insulator-semiconductor structures with an insulating layer of polynucleotides, and their monomer components on the surface

    Energy Technology Data Exchange (ETDEWEB)

    Yafyasov, A. M., E-mail: yafyasov@bk.ru; Bakulev, V. M.; Konorov, P. P.; Bogevolnov, V. V. [St. Petersburg State University, Faculty of Physics (Russian Federation)

    2011-12-15

    It is shown that adsorption of nucleic acid molecules and their monomeric components, i.e., nitrogenous bases, from aqueous solutions results in the formation of an insulating layer on the germanium surface. Comparatively small values of the insulator charge and the surface-state density point to promising applications of nucleotides for both the formation of germanium-based insulator-semiconductor structures with nanoscale insulating layers and low surface-state densities at the phase interface, and for germanium surface passivation. Changes in the electronic properties of the space-charge region of germanium during nucleotide adsorption on its surface can be used as a method for determining the nucleotide molecule concentration in aqueous solutions.

  13. Design and evaluation of brushless electrical generators

    Science.gov (United States)

    Collins, F. A.; Ellis, J. N.

    1970-01-01

    Ten design manuals assembled and nine computer programs are developed for evaluation of proposed designs of brushless rotating electrical generators. Design manual package provides all information required for generator design, and computer programs permit calculation of performance of specific designs including effects of materials.

  14. Determination of threshold and maximum operating electric stresses for selected high voltage insulations. Task III. Investigation of high voltage capacitor insulation. Progress report No. 4

    Energy Technology Data Exchange (ETDEWEB)

    Sosnowski, M.; Eager, G.S. Jr.

    1984-03-01

    This report covers the investigation of threshold voltage of capacitor insulation. The experimental work was performed on samples prepared from commercial polypropylene insulated, liquid-filled capacitors. The samples were vacuum-impregnated with the original capacitor insulating liquid obtained from the manufacturer. A limited number of full-size capacitor elements also were tested. Impulse voltage breakdown tests with dc voltage prestressing were performed at room temperature and 75/sup 0/C. From the results of these tests, the threshold voltage of the samples of the capacitor insulation was determined at both temperatures and that of the whole capacitor elements at room temperature. The threshold voltage of the capacitor insulation was found to be approximately equal to the impulse breakdown voltage. No difference was found between the threshold voltage at room temperature and at 75/sup 0/C. The threshold voltage of the whole capacitor elements at room temperature was found to be equal to approximately 80% of the threshold voltage of the capacitor insulation samples.

  15. EVALUATION OF THERMAL INSULATION FOR THREE DIFFERENT MATERIALS USED IN CONSTRUCTION AND COMPLETION OF EXTERNAL WALLS

    Directory of Open Access Journals (Sweden)

    Marcio Carlos Navroski

    2010-05-01

    Full Text Available Summers increasingly hot are bringing large thermal problems within homes and businesses, leading to increased demand for installation of air conditioners and the consequent high energy consumption. Constructions with thermal insulation on its external walls thatcould reduce energy use or even supply the use of such equipment. Due to these factors the present study was to evaluate the insulation in three boxes built with different materials, one made of wooden boards with plain walls, and two built with plywood, wall insulation andinterior walls filled with rice husk and Styrofoam®. The boxes were built after placed in drying oven at 40 °C, then noted the temperature inside the same interval every five minutes using a digital thermometer. The box with inner Styrofoam® showed the lowest variation among the three evaluated, followed by the box of rice husk. These two materials also showed good thermal initial, unlike the box built only with wood, which showed a large interiorheating, lay in a drying oven.

  16. Evaluation of Experimental Parameters in the Accelerated Aging of Closed-Cell Foam Insulation

    Energy Technology Data Exchange (ETDEWEB)

    Stovall, Therese K [ORNL; Vanderlan, Michael [ORNL; Atchley, Jerald Allen [ORNL

    2012-12-01

    The thermal conductivity of many closed-cell foam insulation products changes over time as production gases diffuse out of the cell matrix and atmospheric gases diffuse into the cells. Thin slicing has been shown to be an effective means of accelerating this process in such a way as to produce meaningful results. Efforts to produce a more prescriptive version of the ASTM C1303 standard test method led to the ruggedness test described here. This test program included the aging of full size insulation specimens for time periods of five years for direct comparison to the predicted results. Experimental parameters under investigation include: slice thickness, slice origin (at the surface or from the core of the slab), thin slice stack composition, product facings, original product thickness, product density, and product type. The test protocol has been completed and this report provides a detailed evaluation of the impact of the test parameters on the accuracy of the 5-year thermal conductivity prediction.

  17. Sustainability evaluation of decentralized electricity generation

    Energy Technology Data Exchange (ETDEWEB)

    Karger, Cornelia R.; Hennings, Wilfried [Research Centre Juelich, Programme Group Humans, Environment, Technology (MUT), 52425 Juelich (Germany)

    2009-04-15

    Decentralized power generation is gaining significance in liberalized electricity markets. An increasing decentralization of power supply is expected to make a particular contribution to climate protection. This article investigates the advantages and disadvantages of decentralized electricity generation according to the overall concept of sustainable development. On the basis of a hierarchically structured set of sustainability criteria, four future scenarios for Germany are assessed, all of which describe different concepts of electricity supply in the context of the corresponding social and economic developments. The scenarios are developed in an explorative way according to the scenario method and the sustainability criteria are established by a discursive method with societal actors. The evaluation is carried out by scientific experts. By applying an expanded analytic hierarchy process (AHP), a multicriteria evaluation is conducted that identifies dissent among the experts. The results demonstrate that decentralized electricity generation can contribute to climate protection. The extent to which it simultaneously guarantees security of supply is still a matter of controversy. However, experts agree that technical and economic boundary conditions are of major importance in this field. In the final section, the article discusses the method employed here as well as implications for future decentralized energy supply. (author)

  18. Effects of Thermal and Solvent Aging on Breakdown Voltage of TPE, PBT/PET Alloy, and PBT Insulated Low Voltage Electric Wire

    Directory of Open Access Journals (Sweden)

    Eun-Soo Park

    2013-01-01

    Full Text Available Tests were performed to evaluate the effects of thermal and solvent aging on the mechanical and dielectric breakdown properties of four types of polyester resins, namely, the insulation layer of poly(butylene terephthalat (PBT- based thermoplastic elastomer (TPE, TPE1, poly(butylene 2,6-naphthalate-based TPE (TPE2, PBT/poly(ethylene terephthalate alloy (Alloy, and PBT extruded onto a copper conductor of low voltage electric wire. The tensile specimens used in this series were prepared from the same extruded resins. The prepared electric wires and tensile specimens were thermally aged in air and in toluene, xylene, TCB, and NMP. When Alloy and PBT were thermally aged in toluene, xylene and TCB at 120°C for 6 h, the tensile properties were significantly decreased compared to TPE1 and TPE2 at the same condition. The reduction of elongation at break of Alloy was more discernible than that of PBT. This result indicated that Alloy is more affected by thermal and solvent ageing. Among them, TPE2 showed the highest breakdown voltage (BDV, and it has also the highest BDV after thermal and solvent aging.

  19. Temperature and electric field induced metal-insulator transition in atomic layer deposited VO2 thin films

    Science.gov (United States)

    Tadjer, Marko J.; Wheeler, Virginia D.; Downey, Brian P.; Robinson, Zachary R.; Meyer, David J.; Eddy, Charles R.; Kub, Fritz J.

    2017-10-01

    Amorphous vanadium oxide (VO2) films deposited by atomic layer deposition (ALD) were crystallized with an ex situ anneal at 660-670 °C for 1-2 h under a low oxygen pressure (10-4 to 10-5 Torr). Under these conditions the crystalline VO2 phase was maintained, while formation of the V2O5 phase was suppressed. Electrical transition from the insulator to the metallic phase was observed in the 37-60 °C range, with an ROFF/RON ratio of up to about 750 and ΔTC ≅ 7-10 °C. Lateral electric field applied across two-terminal device structures induced a reversible phase change, with a room temperature transition field of about 25 kV/cm in the VO2 sample processed with the 2 h long O2 anneal. Both the width and slope of the field induced MIT I-V hysteresis were dependent upon the VO2 crystalline quality.

  20. Evaluation of the contact angle and frost resistance of hydrophobised heat-insulating mortars with polystyrene

    Science.gov (United States)

    Barnat-Hunek, Danuta; Łagód, Grzegorz; Klimek, Beata

    2017-07-01

    The aim of the research presented in the paper was to evaluate the feasibility of using hydrophobic preparation based on organosilicon compounds for surface protection on the heat-insulating mortars modified with polystyrene. The work discusses issues related to wettability, absorptivity and frost resistance of the surface layer of mortars. The experimental part pertains to the physical and mechanical properties of polystyrene-modified mortars and the influence of hydrophobic preparation on the contact angle and frost resistance. The frost resistance of mortars was examined following 25 cycles of freezing and thawing. The contact angle of light mortars (θw) was determined before and after the tests of frost resistance, in the function of time using a single measurement liquid. This provided a basis for calculating the surface free energy with Neumann method, characterizing the wettability and adhesion of mortars under normal conditions and with damages resulting from frost weathering. The structure of mortars and the adhesion of lightweight aggregate to cement paste were presented by means of scanning electron microscopy. The studies enabled to determine the hydrophobisation efficiency of heat-insulating mortars with polystyrene. The obtained results confirmed the possibility of producing heat-insulating mortars modified with polystyrene along with proper surface protection against moisture and frost.

  1. Low Temperature and High Pressure Evaluation of Insulated Pressure Vessels for Cryogenic Hydrogen Storage

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, S.; Martinez-Frias, J.; Garcia-Villazana, O.

    2000-06-25

    Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LH{sub 2}) or ambient-temperature compressed hydrogen (CH{sub 2}). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (fuel flexibility, lower energy requirement for hydrogen liquefaction and reduced evaporative losses). The work described here is directed at verifying that commercially available pressure vessels can be safely used to store liquid hydrogen. The use of commercially available pressure vessels significantly reduces the cost and complexity of the insulated pressure vessel development effort. This paper describes a series of tests that have been done with aluminum-lined, fiber-wrapped vessels to evaluate the damage caused by low temperature operation. All analysis and experiments to date indicate that no significant damage has resulted. Required future tests are described that will prove that no technical barriers exist to the safe use of aluminum-fiber vessels at cryogenic temperatures.

  2. Field Evaluation of Highly Insulating Windows in the Lab Homes: Winter Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Graham B.; Widder, Sarah H.; Bauman, Nathan N.

    2012-06-01

    This field evaluation of highly insulating windows was undertaken in a matched pair of 'Lab Homes' located on the Pacific Northwest National Laboratory (PNNL) campus during the 2012 winter heating season. Improving the insulation and solar heat gain characteristics of a home's windows has the potential to significantly improve the home's building envelope and overall thermal performance by reducing heat loss (in the winter), and cooling loss and solar heat gain (in the summer) through the windows. A high quality installation and/or window retrofit will also minimize or reduce air leakage through the window cavity and thus also contribute to reduced heat loss in the winter and cooling loss in the summer. These improvements all contribute to decreasing overall annual home energy use. Occupant comfort (non-quantifiable) can also be increased by minimizing or eliminating the cold 'draft' (temperature) many residents experience at or near window surfaces that are at a noticeably lower temperature than the room air temperature. Lastly, although not measured in this experiment, highly insulating windows (triple-pane in this experiment) also have the potential to significantly reduce the noise transmittance through windows compared to standard double-pane windows. The metered data taken in the Lab Homes and data analysis presented here represent 70 days of data taken during the 2012 heating season. As such, the savings from highly insulating windows in the experimental home (Lab Home B) compared to the standard double-pane clear glass windows in the baseline home (Lab Home A) are only a portion of the energy savings expected from a year-long experiment that would include a cooling season. The cooling season experiment will take place in the homes in the summer of 2012, and results of that experiment will be reported in a subsequent report available to all stakeholders.

  3. Electric breakdowns of the "plasma capacitors" occurs on insulation coating of the ISS surface

    Science.gov (United States)

    Homin, Taras; Korsun, Anatolii

    High electric fields and currents are occurred in the spacecrafts plasma environment by onboard electric generators. Thus the high voltage solar array (SA) of the American segment of International Space Station (ISS) generates potential 160 V. Its negative pole is shorted to the frames of all the ISS segments. There is electric current between the SA and the frame through the plasma environment, i.e. electric discharge occurs. As a result a potential drop exists between the frames of all the ISS segments and the environmental plasma [1], which is cathode drop potential varphi _{c} defined. When ISS orbiting, the φc varies greatly in the range 0-100 V. A large area of the ISS frames and SA surface is coated with a thin dielectric film. Because of cathode drop potential the frame surfaces accumulate ion charges and the SA surfaces accumulate electron charges. These surfaces become plasma capacitors, which accumulate much charge and energy. Micrometeorite impacts or buildup of potential drop in excess of breakdown threshold varphi_{b} (varphi _{c} > varphi _{b} = 60 V) may cause breakdowns of these capacitors. Following a breakdown, the charge collected at the surfaces disperses and transforms into a layer of dense plasma [2]. This plasma environment of the spacecraft produces great pulsed electric fields E at the frame surfaces as well as heavy currents between construction elements which in turn induce great magnetic fields H. Therefore the conductive frame and the environmental plasma is plasma inductors. We have calculated that the densities of these pulsing and high-frequency fields E and H generated in the plasma environment of the spacecraft may exceed values hazardous to human. Besides, these fields must induce large electromagnetic impulses in the space-suit and in the power supply and control circuits of onboard systems. During astronaut’s space-suit activity, these fields will penetrate the space-suit and the human body with possible hazardous effects

  4. Electrically insulating properties of the 5d double perovskite Sr2YOsO6

    Science.gov (United States)

    Li, Jinghua; Wang, Xia; Wang, Hongyuan; Matsushita, Yoshitaka; Alexei, Belik A.; Kolodiazhnyi, Taras; Xu, Gang; Shi, Youguo; Guo, Yanfeng; Yamaura, Kazunari; Chen, Ying

    2017-09-01

    A high-pressure-synthesized double perovskite Sr2YOsO6 was investigated by synchrotron X-ray diffraction and measurements of its magnetic susceptibility, specific heat capacity, complex impedance, and complex dielectric constant. It crystallized into a monoclinic double perovskite structure (P21/n) with complete ordering of the Y and Os atoms. Its magnetic behaviors, including the antiferromagnetic transition temperature (˜52 K), Curie-Weiss effective moment [3.48(5) μB/Os], and Weiss temperature [-350.1(7) K], were close to the respective values of Sr2YOsO6 previously synthesized without an applied pressure of 6 GPa. Transport property measurements revealed that the lower limit of the activation energy was 192(1) meV and the charge gap remained open regardless of the presence of magnetic order, conflicting with the electron delocalization predicted by theoretical calculations. Further consideration, including theoretical and experimental investigations of the roles of spin-orbit coupling and U of the 5d electrons of Os 5d-t2g3, may assist in understanding the general magnetic and insulating behaviors of quasi-half-filled 5d-t2g3oxides in the perovskite category toward the use of 5d double perovskite for magnetic applications.

  5. Characterization of Chemical Trends in Magnetically Doped, Electrically Gated Topological Insulator Thin Films

    Science.gov (United States)

    Richardella, Anthony; Kandala, Abhinav; Lee, Joon Sue; Fraleigh, Robbie; Samarth, Nitin; Liu, Minhao; Ong, Nai Phuan; Tao, Jing

    2014-03-01

    Interfacing topological insulators (TIs) with magnetism breaks time reversal symmetry and opens a gap in the surface states at the Dirac point. This results in novel phenomena, such as the recently reported quantized conductance at zero applied external magnetic field due to the quantum anomalous Hall effect (QAHE) in Cr doped (BixSb1-x)2 Te3 [C-Z. Chang, et al., Science 340, 167 (2013)]. We have studied magnetically doped (BixSb1-x)2 Te3 thin films grown by MBE on SrTiO3(111) (STO) substrates using Cr, Fe and Mn as magnetic dopants and as a function of the Bi and Sb composition. These films are carefully characterized by XRD, AFM, SQUID magnetometry and TEM. The chemical composition is determined using SIMS, RBS and XRF. Low temperature transport shows a large gate-tunable Hall effect in Cr doped samples and systematically varying longitudinal magneto-conductance as the Fermi energy is tuned through the Dirac point. The origin of ferromagnetism and its dependence on the chemical potential, chemical composition and sample thickness is discussed. Funded by DARPA and ARO-MURI.

  6. Temperature dependent electrical transport in single Ge nanowires near insulator-metal transition

    Science.gov (United States)

    Raychaudhuri, Arup Kumar; Seth, Shaili; Das, Kaustuv

    We report low temperature (4K Resolution Transmission Electron Microscope and established their crystalline quality. A single nanowire dispersed on a Si/SiO2 substrate was connected by Cr/Au contacts made by electron beam lithography in 2-probe / 4-probe configurations. The undoped nanowires have a room temperature resistivity (ρ) of 2 ohm.cm or more (estimated carrier concentration ~1015/cm3) and below the 25K (where it shows carrier freeze out) the ρ rises to high value of 35 ohm.cm. For nanowires with ρ <= .01 ohm.cm at 300K , low temperature ρ becomes finite, signaling transition to a metallic state with negative temperature co-efficient of ρ. The critical composition for the insulator-metal transition is more than an order higher than that observed in the bulk. At low T (<25K) resistivity data in this regime can be fitted to weak-localization form ρ =ρ0 - aTp/2 with ρ0 the NW's ~ 0.5-3.5 mohm.cm, with the exponent p ~ 3-4 as expected from theoretical predictions. Acknowldge Financial Support from Department od Science and Technology, Government of India for Sponsored Project.

  7. Electric characteristics of organic thin-film transistors and logic circuits with a ferroelectric gate insulator

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yong Suk [Electronics and Telecommunications Research Institute, Yuseong, Daejon 305-350 (Korea, Republic of)], E-mail: jullios@etri.re.kr; Chu, Hye Yong; Kim, Seong Hyun; Lim, Sang Chul; Koo, Jae Bon; Lee, Jung Hun; Ku, Chan Hoe; Lee, Jeong-Ik; Do, Lee-Mi; Hwang, Chi Sun; Park, Sang-He Ko; Kim, Gi Heon; Jung, Sung Mook [Electronics and Telecommunications Research Institute, Yuseong, Daejon 305-350 (Korea, Republic of)

    2007-07-16

    Organic electronic devices using a pentacene have improved importantly in the last several years. We fabricated pentacene organic thin-film transistors (OTFTs) with dielectric SiO{sub 2} and ferroelectric Pb(Zr{sub 0.3},Ti{sub 0.7})O{sub 3} (PZT) gate insulators. The organic devices using SiO{sub 2} and PZT films had the field-effect mobility of approximately 0.1 and 0.004 cm{sup 2}/V s, respectively. The drain current in the transfer curve of pentacene/PZT transistors showed a hysteresis behavior originated in a ferroelectric polarization switching. In order to investigate the polarization effect of PZT gate dielectrics in a logic circuit, the simple voltage inverter using SiO{sub 2} and PZT films was fabricated and measured by an output-input measurement. The gain of inverter at the poling-down state was approximately 7.2 and it was three times larger than the value measured at the poling-up state.

  8. Evaluation of Cow Milk Electrical Conductivity Measurements

    Directory of Open Access Journals (Sweden)

    Constantin Gavan

    2017-11-01

    Full Text Available The efficiency of subclinical mastitis diagnosis using an electrical conductivity (EC meter was evaluated in the dairy farm of Agricultural Research and Development Station ( ARDS Simnic Craiova. The results were compared with those obtained by using the California Mastitis Test (CMT and the Somatic Cell Count (SCC.The milk quarter samples ( 1176 from Holstein Friesian cows were analyzed between September and December 2015. The EC evaluation with  the EC meter  ,showed a high proportion of results differing from SCC and CMT results. The CMT still shows to be the most accessible and efficient test in comparison to the EC meter tested.

  9. Do clinical examination gloves provide adequate electrical insulation for safe hands-on defibrillation? I: Resistive properties of nitrile gloves.

    Science.gov (United States)

    Deakin, Charles D; Lee-Shrewsbury, Victoria; Hogg, Kitwani; Petley, Graham W

    2013-07-01

    Uninterrupted chest compressions are a key factor in determining resuscitation success. Interruptions to chest compression are often associated with defibrillation, particularly the need to stand clear from the patient during defibrillation. It has been suggested that clinical examination gloves may provide adequate electrical resistance to enable safe hands-on defibrillation in order to minimise interruptions. We therefore examined whether commonly used nitrile clinical examination gloves provide adequate resistance to current flow to enable safe hands-on defibrillation. Clinical examination gloves (Kimberly Clark KC300 Sterling nitrile) worn by members of hospital cardiac arrest teams were collected immediately following termination of resuscitation. To determine the level of protection afforded by visually intact gloves, electrical resistance across the glove was measured by applying a DC voltage across the glove and measuring subsequent resistance. Forty new unused gloves (control) were compared with 28 clinical (non-CPR) gloves and 128 clinical (CPR) gloves. One glove in each group had a visible tear and was excluded from analysis. Control gloves had a minimum resistance of 120 kΩ (median 190 kΩ) compared with 60 kΩ in clinical gloves (both CPR (median 140 kΩ) and non-CPR groups (median 160 kΩ)). Nitrile clinical examination gloves do not provide adequate electrical insulation for the rescuer to safely undertake 'hands-on' defibrillation and when exposed to the physical forces of external chest compression, even greater resistive degradation occurs. Further work is required to identify gloves suitable for safe use for 'hands-on' defibrillation. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Insulation Coordination and Failure Mitigation Concerns for Roust Dc Electrical Power Systems (Preprint)

    Science.gov (United States)

    2014-05-01

    create light, powerful and controllable motors through dc brushless technology. Unfortunately, some complications are created by the presence of high...have been developed to qualify random-wound induction motors for use with pulse-width-modulated drives to control motor speed and/or torque. This...Systems (Type I) Used in Rotating Electrical Machines Fed From Voltage Converters—Qualification and Quality Control Tests, International Standard

  11. Effect of multi-structured zinc oxide on the electrical properties of polypropylene insulating materials

    Science.gov (United States)

    Zha, Jun-Wei; Cheng, Qi; Yan, Hong-Da; Li, Wei-Kang; Dang, Zhi-Min

    2017-08-01

    In this paper, polypropylene (PP) nanocomposites filled with ZnO nanoparticles, nanowires and tera-needle-like whiskers were prepared by a melt blending method. The effects of multi-structure ZnO fillers on space charge, breakdown strength and electrical conductive current of PP nanocomposites were investigated. The nanocomposites presented a remarkable suppression on space charge by adding ZnO nanowires, while the addition of ZnO nanoparticles and tera-needle-like whiskers did not effectively suppress the space charge accumulation. The electrical field distortion occurred in the inner of the PP filled with ZnO nanoparticles and tera-needle-like whiskers were about 1.8 kV mm-1 and 3.3 kV mm-1, respectively. Compared with pure PP, the breakdown strength of the PP nanocomposites filled with ZnO nanoparticles and nanowires increased, while they decreased in PP nanocomposites filled with tera-needle-like ZnO whiskers. This work indicated that the improvements on the electrical properties, especially the charge transport and space charge suppression in the nanocomposites were closely related to the different structure of ZnO.

  12. 78 FR 29159 - Electric Power Research Institute; Seismic Evaluation Guidance

    Science.gov (United States)

    2013-05-17

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Electric Power Research Institute; Seismic Evaluation Guidance AGENCY: Nuclear Regulatory... issuing an endorsement letter of Electric Power Research Institute (EPRI) Report, ``Seismic Evaluation...

  13. Cooling of electrically insulated high voltage electrodes down to 30 mK Kühlung von elektrisch isolierten Hochspannungselektroden bis 30 mK

    CERN Document Server

    Eisel, Thomas; Bremer, J

    2011-01-01

    The Antimatter Experiment: Gravity, Interferometry, Spectroscopy (AEGIS) at the European Organization for Nuclear Research (CERN) is an experiment investigating the influence of earth’s gravitational force upon antimatter. To perform precise measurements the antimatter needs to be cooled to a temperature of 100 mK. This will be done in a Penning trap, formed by several electrodes, which are charged with several kV and have to be individually electrically insulated. The trap is thermally linked to a mixing chamber of a 3He-4He dilution refrigerator. Two link designs are examined, the Rod design and the Sandwich design. The Rod design electrically connects a single electrode with a heat exchanger, immersed in the helium of the mixing chamber, by a copper pin. An alumina ring and the helium electrically insulate the Rod design. The Sandwich uses an electrically insulating sapphire plate sandwiched between the electrode and the mixing chamber. Indium layers on the sapphire plate are applied to improve the ther...

  14. Electrically Insulated Sensing of Respiratory Rate and Heartbeat Using Optical Fibers

    Directory of Open Access Journals (Sweden)

    Ernesto Suaste-Gómez

    2014-11-01

    Full Text Available Respiratory and heart rates are among the most important physiological parameters used to monitor patients’ health. It is important to design devices that can measure these parameters without risking or altering the subject’s health. In this context, a novel sensing method to monitor simultaneously the heartbeat and respiratory rate signals of patients within an electrically safety environment was developed and tested. An optical fiber-based sensor was used in order to detect two optical phenomena. Photo-plethysmography and the relation between bending radius and attenuation of optical fiber were coupled through a single beam light traveling along this fiber.

  15. Insulated Foamy Viral Vectors

    Science.gov (United States)

    Browning, Diana L.; Collins, Casey P.; Hocum, Jonah D.; Leap, David J.; Rae, Dustin T.; Trobridge, Grant D.

    2016-01-01

    Retroviral vector-mediated gene therapy is promising, but genotoxicity has limited its use in the clinic. Genotoxicity is highly dependent on the retroviral vector used, and foamy viral (FV) vectors appear relatively safe. However, internal promoters may still potentially activate nearby genes. We developed insulated FV vectors, using four previously described insulators: a version of the well-studied chicken hypersensitivity site 4 insulator (650cHS4), two synthetic CCCTC-binding factor (CTCF)-based insulators, and an insulator based on the CCAAT box-binding transcription factor/nuclear factor I (7xCTF/NF1). We directly compared these insulators for enhancer-blocking activity, effect on FV vector titer, and fidelity of transfer to both proviral long terminal repeats. The synthetic CTCF-based insulators had the strongest insulating activity, but reduced titers significantly. The 7xCTF/NF1 insulator did not reduce titers but had weak insulating activity. The 650cHS4-insulated FV vector was identified as the overall most promising vector. Uninsulated and 650cHS4-insulated FV vectors were both significantly less genotoxic than gammaretroviral vectors. Integration sites were evaluated in cord blood CD34+ cells and the 650cHS4-insulated FV vector had fewer hotspots compared with an uninsulated FV vector. These data suggest that insulated FV vectors are promising for hematopoietic stem cell gene therapy. PMID:26715244

  16. A REVIEW OF COMPARATIVE EVALUATION OF THERMAL INSULATION MATERIALS FOR BUILDING WALL APPLICATIONS

    OpenAIRE

    Dr. RK. Jain *, Chouhan Balaji, Dhananjay Singh

    2016-01-01

    Attention towards the thermal performance of building materials, particularly thermal insulation systems for buildings, has grown in recent years. Thermal insulation of building walls has a significant effect on the reduction of thermal energy consumption in buildings Making a thermal insulation of a building external wall can in terms of economic aspects be approached as an investment. In this investment the cost is related to the purchase, transport and laying the insulation, whereas the pr...

  17. Environmental and Sustainable Technology Evaluation: Mold-Resistant Armacell Insulation--Armacell LLC, AP Armaflex Black

    Science.gov (United States)

    The ESTE test program measured the mold resistance of Armacell AP Armaflex Black insulation. Tests for emissions of VOCs and formaldehyde were also performed. AP Armaflex Roll Insulation is a black flexible closed-cell, fiber-free elastomeric thermal insulation. The expanded clos...

  18. Development of non-cellulosic insulation for transformers. Quarterly report No. 2, April 1980. General Electric No. CCR-80-07

    Energy Technology Data Exchange (ETDEWEB)

    Fessler, W.A.

    1980-01-01

    Work has continued on the development of an analytical model to demonstrate the advantages in both materials and losses to be gained by the utilization of thin insulation in transformers. Measurement of mechanical and electrical properties of film materials is underway. The aging and material compatibility of synthetic films in transformer oil, silicone, and R113 is being studied in a sealed-tube aging program. Several materials are on test and others are being readied for test.

  19. The change of electric field and of some other insulating properties during isochronal annealing in thermally poled Ge-doped silica films

    DEFF Research Database (Denmark)

    Liu, Q.M.; Poumellec, B.; Braga, D.

    2005-01-01

    The secondary electron emission contrast between poled and unpoled regions in thermally poled Ge-doped silica films were measured according to different annealing temperatures and electron doses with electron acceleration energy of 5 keV. It is used for measuring the change on annealing of poling...... induced electric field and other insulating properties like electron traps population and conductivity in high field. Concerning the change of the contrast at low dose arising from the poling electric field, we show that this field begins to disappear at around 450 degrees C and is erased completely...

  20. 78 FR 13097 - Electric Power Research Institute; Seismic Evaluation Guidance

    Science.gov (United States)

    2013-02-26

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Electric Power Research Institute; Seismic Evaluation Guidance AGENCY: U.S. Nuclear Regulatory... issuing an endorsement letter with clarifications of Electric Power Research Institute (EPRI)-1025287...

  1. Material characterization and thermoforming of polyethylene terephthalate film for electrical insulation: Topical report

    Energy Technology Data Exchange (ETDEWEB)

    Carey, D.A.; Smith, B.P.

    1987-12-01

    Differential scanning calorimetry (DSC) was used to determine as-received glass transition, crystallization, and melting temperatures of polyethylene terephthalate (PET). A Box-Behnken statistical designed experiment was used to evaluate the effect of forming temperature, forming rate, and heat-set temperature on shrinkage, tear resistance, and thermal properties. At a forming temperature of 88/sup 0/C and heat-set temperature of 180/sup 0/C, good-quality PET parts were produced. The optimum forming time appears to be either 0.5 min or 5.0 min. In addition, inductively coupled argon plasma emission spectroscopy (ICAP) was used to determine the catalyst system for both PET sheets from two vendors.

  2. Silanization of boron nitride nanosheets (BNNSs) through microfluidization and their use for producing thermally conductive and electrically insulating polymer nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Seyhan, A.Tuğrul, E-mail: atseyhan@anadolu.edu.tr [Department of Materials Science and Engineering, Anadolu University - AU, Iki Eylul Campus, 26550 Eskisehir (Turkey); Composite Materials Manufacturing Science Laboratory (CMMSL), Research and Application Center of Civil Aviation (RACCA), Anadolu University - AU, Iki Eylul Campus, 26550 Eskisehir (Turkey); Göncü, Yapıncak; Durukan, Oya; Akay, Atakan; Ay, Nuran [Department of Materials Science and Engineering, Anadolu University - AU, Iki Eylul Campus, 26550 Eskisehir (Turkey)

    2017-05-15

    to make it possible to utilize them as promising filler constituent in manufacturing thermally conductive and electrically insulating polymer nanocomposites that could be considered as whole or a part of a heat-releasing device.

  3. Silanization of boron nitride nanosheets (BNNSs) through microfluidization and their use for producing thermally conductive and electrically insulating polymer nanocomposites

    Science.gov (United States)

    Seyhan, A. Tuğrul; Göncü, Yapıncak; Durukan, Oya; Akay, Atakan; Ay, Nuran

    2017-05-01

    to make it possible to utilize them as promising filler constituent in manufacturing thermally conductive and electrically insulating polymer nanocomposites that could be considered as whole or a part of a heat-releasing device.

  4. Development and analysis of insulation constructions for aerospace wiring applications

    Science.gov (United States)

    Slenski, George A.; Woodford, Lynn M.

    1993-03-01

    The Wright Laboratory Materials Directorate at WPAFB, Ohio recently completed a research and development program under contract with the McDonnell Douglas Aerospace Company, St. Louis, Missouri. Program objectives were to develop wire insulation performance requirements, evaluate candidate insulations, and prepare preliminary specification sheets on the most promising candidates. Aircraft wiring continues to be a high maintenance item and a major contributor to electrically-related aircraft mishaps. Mishap data on aircraft show that chafing of insulation is the most common mode of wire failure. Improved wiring constructions are expected to increase aircraft performance and decrease costs by reducing maintenance actions. In the laboratory program, new insulation constructions were identified that had overall improved performance in evaluation tests when compared to currently available MIL-W-81381 and MIL-W-22759 wiring. These insulations are principally aromatic polyimide and crosslinked ethylene tetrafluoroethylene (ETFE), respectively. Candidate insulations identified in preliminary specification sheets were principally fluoropolymers with a polyimide inner layer. Examples of insulation properties evaluated included flammability, high temperature mechanical and electrical performance, fluid immersion, and susceptibility to arc propagation under applied power chafing conditions. Potential next generation wire insulation materials are also reviewed.

  5. Insulation for crack protection of brick liners at Tucson Electric Power Company's Irvington Station

    Energy Technology Data Exchange (ETDEWEB)

    Bochicchio, V.A.; Hodder, T.; Olmsted, C.D.

    1986-04-01

    The chimney designed and constructed for Units 3 and 4 of the Irvington Generating Station Coal Conversion Project consists of a concrete shell with two acid-resistant brick liners. The liners incorporate an exterior layer of fiberglass insulation to reduce the temperature gradient through the brick wall and, hence, the tensile stresses in the brickwork. The reduction or elimination of cracking by means of insulation is expected to result in improved performance of the lining and reduced maintenance. This paper discusses the stresses involved, the usual crack development mechanism, stress testing background, and the Irvington Station brick liner insulation application.

  6. Numerical Evaluation of Mode 1 Stress Intensity Factor as a Function of Material Orientation For BX-265 Foam Insulation Material

    Science.gov (United States)

    Knudsen, Erik; Arakere, Nagaraj K.

    2006-01-01

    Foam; a cellular material, is found all around us. Bone and cork are examples of biological cell materials. Many forms of man-made foam have found practical applications as insulating materials. NASA uses the BX-265 foam insulation material on the external tank (ET) for the Space Shuttle. This is a type of Spray-on Foam Insulation (SOFI), similar to the material used to insulate attics in residential construction. This foam material is a good insulator and is very lightweight, making it suitable for space applications. Breakup of segments of this foam insulation on the shuttle ET impacting the shuttle thermal protection tiles during liftoff is believed to have caused the space shuttle Columbia failure during re-entry. NASA engineers are very interested in understanding the processes that govern the breakup/fracture of this complex material from the shuttle ET. The foam is anisotropic in nature and the required stress and fracture mechanics analysis must include the effects of the direction dependence on material properties. Material testing at NASA MSFC has indicated that the foam can be modeled as a transversely isotropic material. As a first step toward understanding the fracture mechanics of this material, we present a general theoretical and numerical framework for computing stress intensity factors (SIFs), under mixed-mode loading conditions, taking into account the material anisotropy. We present mode I SIFs for middle tension - M(T) - test specimens, using 3D finite element stress analysis (ANSYS) and FRANC3D fracture analysis software, developed by the Cornel1 Fracture Group. Mode I SIF values are presented for a range of foam material orientations. Also, NASA has recorded the failure load for various M(T) specimens. For a linear analysis, the mode I SIF will scale with the far-field load. This allows us to numerically estimate the mode I fracture toughness for this material. The results represent a quantitative basis for evaluating the strength and

  7. Partial Discharge Characteristics of Polymer Nanocomposite Materials in Electrical Insulation: A Review of Sample Preparation Techniques, Analysis Methods, Potential Applications, and Future Trends

    Science.gov (United States)

    Izzati, Wan Akmal; Adzis, Zuraimy; Shafanizam, Mohd

    2014-01-01

    Polymer nanocomposites have recently been attracting attention among researchers in electrical insulating applications from energy storage to power delivery. However, partial discharge has always been a predecessor to major faults and problems in this field. In addition, there is a lot more to explore, as neither the partial discharge characteristic in nanocomposites nor their electrical properties are clearly understood. By adding a small amount of weight percentage (wt%) of nanofillers, the physical, mechanical, and electrical properties of polymers can be greatly enhanced. For instance, nanofillers in nanocomposites such as silica (SiO2), alumina (Al2O3) and titania (TiO2) play a big role in providing a good approach to increasing the dielectric breakdown strength and partial discharge resistance of nanocomposites. Such polymer nanocomposites will be reviewed thoroughly in this paper, with the different experimental and analytical techniques used in previous studies. This paper also provides an academic review about partial discharge in polymer nanocomposites used as electrical insulating material from previous research, covering aspects of preparation, characteristics of the nanocomposite based on experimental works, application in power systems, methods and techniques of experiment and analysis, and future trends. PMID:24558326

  8. Evaluation of conjugate, radial heat transfer in an internally insulated composite pipe

    NARCIS (Netherlands)

    Reurings, C.; Koussios, S.; Bergsma, O.K.; Vergote, K.

    2015-01-01

    In order to compete with steel, a fibre-reinforced composite exhaust wall with a general-purpose resin system requires an effective but lightweight insulation layer. However a lack of experimental methods for heat transfer from turbulent gas flow to pipe walls lined with a porous insulation layer

  9. Determination of copper in liquid and solid insulation for large electrical equipment by ICP-OES. Application to copper contamination assessment in power transformers.

    Science.gov (United States)

    Bruzzoniti, Maria Concetta; De Carlo, Rosa Maria; Sarzanini, Corrado; Maina, Riccardo; Tumiatti, Vander

    2012-09-15

    Copper is one of the main constituents of the components in power transformers and its presence both in liquid (mineral oil) and in solid (Kraft paper) insulators can lead to enhanced dielectric losses and to the subsequent deterioration of their insulating properties. Recently the latter have been correlated to plant failures which in turn may have severe impact on the environment. This paper describes the direct analysis of copper in insulating mineral oil by ICP-OES and how it was first optimized compared to the official American Society for Testing and Materials (ASTM) D7151 method. Detection and quantification limits of 8.8 μg kg(-1) and 29.3 μg kg(-1) were obtained. Secondly, copper determination was improved by coupling a microwave assisted dissolution procedure of the mineral oil which avoided the problems, in the real samples, due to the presence of solid species of copper which cannot be nebulized following traditional methods described in literature. Sixteen mineral insulating oils sampled from transformers in service were analyzed before and after dissolution. In order to evaluate copper speciation, size fractionation was performed by filtration on PTFE filters (0.45, 1 and 5 μm). This test was performed on all the oil samples. Finally, because of the key role of the solid insulator in failed transformers, the Authors applied the developed method to study the copper deposition tendency onto the insulating Kraft paper tapes exerted by two unused oils (a corrosive and a non-corrosive one) under defined ageing conditions. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Bilayers of Ni3C12S12 and Pt3C12S12: graphene-like 2D topological insulators tunable by electric fields

    Science.gov (United States)

    Silveira, Orlando J.; Lima, Érika N.; Chacham, Hélio

    2017-11-01

    In the present work we predict, through first-principles calculations, that bilayers of the recently synthesized Ni3 C12 S12 and Pt3 C12 S12 layered materials are topological insulators upon electron doping, and that their topological insulator properties can be modulated by the application of electric fields with magnitudes achievable in devices. The electronic structures of both bilayers are characterized by spin–orbit split graphene-like bands, with gap magnitudes that are three orders of magnitude larger than graphene’s. In ribbon geometries, chiral edge modes develop at each side with band dispersions similar to that of Kane–Mele graphene model. Surprisingly, the edge states’ spin-propagation locking occurs even for very thin ribbons. We also find that the response of the electronic structure of both materials to applied electric fields are similar to both graphene and the Kane–Mele model with a Rashba term. All these findings indicate that these bilayer systems can be considered as large-spin–orbit graphene analogues with a strong sensitivity to applied electric fields.

  11. Determining insulation condition of 110kV instrument transformers. Linking PD measurement results from both gas chromatography and electrical method

    Science.gov (United States)

    Dan, C.; Morar, R.

    2017-05-01

    Working methods for on site testing of insulations: Gas chromatography (using the TFGA-P200 chromatographer); Electrical measurements of partial discharge levels using the digital detection, recording, analysis and partial discharge acquisition system, MPD600. First performed, between 2000-2015, were the chromatographic analyses concerning electrical insulating environments of: 102 current transformers, 110kV. Items in operation, functioning in 110/20kV substations. 38 voltage transformers, 110kV also in operation, functioning in 110/20kV substations. Then, electrical measurements of partial discharge inside instrument transformers, on site (power substations) were made (starting in the year 2009, over a 7-year period, collecting data until the year 2015) according to the provisions of standard EN 61869-1:2007 „Instrument transformers. General requirements”, applying, assimilated to it, type A partial discharge test procedure, using as test voltage the very rated 110kV distribution grid voltage. Given the results of two parallel measurements, containing: to this type of failure specific gas amount (H 2) and the quantitative partial discharge’ level, establishing a clear dependence between the quantity of partial discharges and the type and amount of in oil dissolved gases inside equipments affected by this type of defect: partial discharges, was expected. Of the „population” of instrument transformers subject of the two parallel measurements, the dependency between Q IEC (apparent charge) and (H 2) (hydrogen, gas amount dissolved within their insulating environment) represents a finite assemblage situated between the two limits developed on an empirical basis.

  12. Electrical analysis of high dielectric constant insulator and metal gate metal oxide semiconductor capacitors on flexible bulk mono-crystalline silicon

    KAUST Repository

    Ghoneim, Mohamed T.

    2015-06-01

    We report on the electrical study of high dielectric constant insulator and metal gate metal oxide semiconductor capacitors (MOSCAPs) on a flexible ultra-thin (25 μm) silicon fabric which is peeled off using a CMOS compatible process from a standard bulk mono-crystalline silicon substrate. A lifetime projection is extracted using statistical analysis of the ramping voltage (Vramp) breakdown and time dependent dielectric breakdown data. The obtained flexible MOSCAPs operational voltages satisfying the 10 years lifetime benchmark are compared to those of the control MOSCAPs, which are not peeled off from the silicon wafer. © 2014 IEEE.

  13. Electrical transport properties and morphology of topological insulator Bi{sub 2}Se{sub 3} thin films with different thickness prepared by magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Min; Wei, Zhantao; Jin, Rong; Ji, Yaxin; Yan, Yong; Pu, Xiaoyan [Key Laboratory of Advanced Technology of Materials (Ministry of Education), Superconductivity and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China); Yang, Xinsheng, E-mail: xsyang@swjtu.edu.cn [Key Laboratory of Advanced Technology of Materials (Ministry of Education), Superconductivity and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China); Zhao, Yong [Key Laboratory of Advanced Technology of Materials (Ministry of Education), Superconductivity and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China); School of Materials Science and Engineering, University of New South Wales, Sydney, 2052, NSW (Australia)

    2016-03-31

    Topological insulator Bi{sub 2}Se{sub 3} thin films were grown by magnetron sputtering on Si (1 0 0) substrate and their phase structures and electrical properties were studied. The films have good crystalline quality, and their surfaces exhibited terrace-like quintuple layers. In the high temperature region, contribution from surface carrier and bulk conduction band electrons excited from an impurity band; in the low temperature region, surface electron became dominant. The weak antilocalization (WAL) cusp was observed in the magneto-transport measurement at low temperature under low magnetic field. The linear magnetoresistance (MR) under high-field was found, which was associated with the gapless topological surface states and of quantum origin. Insulating tendency was much stronger in thinner films. The WAL effect became weaker in thicker films. The top surface was only partially decoupled. - Highlights: • The linear magnetoresistance is associated with gapless topological surface state. • Insulating tendency is much stronger in thinner films. • The weak antilocalization effect becomes weaker with increasing thickness.

  14. Thermal conductivity and Kapitza resistance of cyanate ester epoxy mix and tri-functional epoxy electrical insulations at superfluid helium temperature

    CERN Document Server

    Pietrowicz, S; Jones, S; Canfer, S; Baudouy, B

    2012-01-01

    In the framework of the European Union FP7 project EuCARD, two composite insulation systems made of cyanate ester epoxy mix and tri-functional epoxy (TGPAP-DETDA) with S-glass fiber have been thermally tested as possible candidates to be the electrical insulation of 13 T Nb3Sn high field magnets under development for this program. Since it is expected to be operated in pressurized superfluid helium at 1.9 K and 1 atm, the thermal conductivity and the Kapitza resistance are the most important input parameters for the thermal design of this type of magnet and have been determined in this study. For determining these thermal properties, three sheets of each material with different thicknesses varying from 245 μm to 598 μm have been tested in steady-state condition in the temperature range of 1.6 K - 2.0 K. The thermal conductivity for the tri-functional epoxy (TGPAP-DETDA) epoxy resin insulation is found to be k=[(34.2±5.5).T-(16.4±8.2)]×10-3 Wm-1K-1 and for the cyanate ester epoxy k=[(26.8±4.8).T- (9.6±5...

  15. Electrical testing and performance evaluation of 1:1 prototype JET ELM control coils

    Energy Technology Data Exchange (ETDEWEB)

    Kanabar, Deven, E-mail: deven@ipr.res.in; Roy, Swati; Ghate, Mahesh; Raj, Piyush; Kundu, Ananya; Kumar, Nitish; Bhavsar, Dhaval; Panchal, Arun; Pradhan, Subrata, E-mail: pradhan@ipr.res.in

    2016-12-15

    Highlights: • An appropriate 1:1 prototype Small and Large ELM coils for JET have been successfully manufactured using indigenous technologies. • ELM coils have been tested extensively to verify and validated their performance with respect to operational requirement of JET. • The test results confirm and validate the electrical performance of ELM coils. - Abstract: Magnet Technology Development Division at Institute for Plasma research is engaged in extensive R & D for appropriate technologies towards manufacturing of Edge Localized Mode (ELM) magnets for Large Tokamak such as Joint European Torus (JET) as well as for Steady State Superconducting Tokamak (SST-1). Under this project, manufacturing of 1:1 prototype of Large and Small JET ELM control coils (CC) is completed incorporating indigenously developed manufacturing and insulation technologies. Performance evaluation of both the types of coil has been completed for its current carrying capability and insulation resistance as required by various operational scenarios of JET. Experimental setups, test procedures and measurements for electrical characterization of both type of ELM control coil has been discussed in this paper.

  16. Energy efficiency and sustainability: evaluation of electricity ...

    African Journals Online (AJOL)

    Tricomponent Model of Attitude), this work presents the results of a systematic survey and analysis of electricity consumer's attitudes, behaviours and practices towards energy use and sustainability. Using the random sampling method, the ...

  17. Correlation analysis between ceramic insulator pollution and acoustic emissions

    Directory of Open Access Journals (Sweden)

    Benjamín Álvarez-Nasrallah

    2015-01-01

    Full Text Available Most of the studies related to insulator pollution are normally performed based on individual analysis among leakage current, relative humidity and equivalent salt deposit density (ESDD. This paper presents a correlation analysis between the leakage current and the acoustic emissions measured in a 230 kV electrical substations in the city of Barranquilla, Colombia. Furthermore, atmospheric variables were considered to develop a characterization model of the insulator contamination process. This model was used to demonstrate that noise emission levels are a reliable indicator to detect and characterize pollution on high voltage insulators. The correlation found amount the atmospheric, electrical and sound variables allowed to determine the relations for the maintenance of ceramic insulators in high-polluted areas. In this article, the results on the behavior of the leakage current in ceramic insulators and the sound produced with different atmospheric conditions are shown, which allow evaluating the best time to clean the insulator at the substation. Furthermore, by experimentation on site and using statistical models, the correlation between ambient variables and the leakage current of insulators in an electrical substation was obtained. Some of the problems that bring the external noise were overcome using multiple microphones and specialized software that enabled properly filter the sound and better measure the variables.

  18. Forced cooling of underground electric power transmission lines. Part II. Heat conduction in the cable insulation of force-cooled underground electrical power transmission systems. Yearly report

    Energy Technology Data Exchange (ETDEWEB)

    Sanders, J.V.; Glicksman, L.R.; Rohsenow, W.M.

    1974-05-01

    Forced-cooled systems for oil-filled pipe-type cable circuits have recently been considered. In such systems the conduction resistance through the paper insulation of the cables is the limiting thermal resistance. Assuming bilateral symmetry, steady-state conditions, and two-dimensional heat transfer, a FORTRAN IV computer program was written to solve the heat conduction problem in the cable insulation for abritrary configurations of a three-cable system. For a steel pipe, a cable system is most susceptible to overheating in the equilateral configuration with the three cables touching. Proximity effects are very significant in forced cooling, especially when cables are not provided with a copper tape under the insulation moisture seal assembly, accounting for as much as 21 percent of the total oil temperature rise between refrigeration stations. This figure, however, is reduced to 8 percent when 0.005 in.-thick copper tape is present.

  19. Sound insulation of dwellings - Legal requirements in Europe and subjective evaluation of acoustical comfort

    DEFF Research Database (Denmark)

    Rasmussen, Birgit; Rindel, Jens Holger

    2003-01-01

    Acoustical comfort is a concept that can be characterised by absence of unwanted sound and by opportunities for acoustic activities without annoying other people. In order to achieve acoustical comfort in dwellings certain requirements have to be fulfilled concerning the airborne sound insulation...... requirement for sound insulation. The findings can also be used as a guide to specify acoustic requirements for dwellings in the future......., the impact sound insulation and the noise level from traffic and building services. For road traffic noise it is well established that an outdoor noise level LAeq, 24 h below 55 dB in a housing area means that approximately 15-20% of the occupants are annoyed by the noise. However, for sound insulation...

  20. Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Podorson, David [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-01-01

    Exterior insulation and finish systems (EIFS) are proprietary synthetic formulations that are applied to the exterior walls of buildings to serve as insulation and exterior cladding. The insulation thickness can vary from less than one inch to a foot or more. In this project the applicability of EIFS for residential deep energy retrofits was investigated through modeling and a case study home. The home was retrofitted using a site-applied four-inch-thick EIFS. Site-specific details were developed as required for the residential retrofit application. Site work and the costs of the EIFS system were documented. The demonstration home was modeled using Building Energy Optimization energy and cost analysis software to explore cost effectiveness of various EIFS insulation thicknesses in two climate locations.

  1. Summary of Activities for Nondestructive Evaluation of Insulation in Cryogenic Tanks

    Science.gov (United States)

    Arens, Ellen

    2012-01-01

    This project was undertaken to investigate methods to non-intrusively determine the existence and density of perlite insulation in the annular region of the cryogenic storage vessels, specifically considering the Launch Complex 39 hydrogen tanks at Kennedy Space Center. Lack of insulation in the tanks (as existed in the pad B hydrogen tank at Kennedy Space Center) results in an excessive loss of commodity and can pose operational and safety risks if precautions are not taken to relieve the excessive gas build-up. Insulation with a density that is higher than normal (due to settling or compaction) may also pose an operational and safety risk if the insulation prevents the system from moving and responding to expansions and contractions as fluid is removed and added to the tank.

  2. Evaluation Methods of Contamination Flashover Voltage Performance of Cylindrical Type Semi-conducting Glaze Porcelain Insulators

    Science.gov (United States)

    Yamada, Kazuma; Hayashi, Akio; Saka, Chiharu; Sakanishi, Kenji; Matsuoka, Ryosuke; Ito, Susumu; Fujii, Osamu

    Higher contamination flashover voltage of a semi-conducting glaze (SG) insulator owes primarily to the drying effect by leakage current flowing in the glaze. Significant reduction in contamination flashover voltage was confirmed on a cylindrical SG insulator when fog density was increased from 0.5g/m3 to 13g/m3 in clean fog test. The effect of de-energized duration between trip-out and re-energization on the contamination flashover voltage of a cylindrical SG insulator under cold-wet switch-on conditions was investigated. As the de-energized duration becomes shorter, the flashover voltage of a cylindrical SG insulator becomes higher. Higher contamination design voltages may be adopted even under cold-wet switch-on conditions.

  3. A comparative study of Mg and Pt contacts on semi-insulating GaAs: electrical and XPS characterization

    Czech Academy of Sciences Publication Activity Database

    Dubecký, F.; Kindl, Dobroslav; Hubík, Pavel; Mičušík, M.; Dubecký, M.; Boháček, P.; Vanko, G.; Gombia, E.; Nečas, V.; Mudroň, J.

    2017-01-01

    Roč. 395, Feb (2017), s. 131-135 ISSN 0169-4332 Institutional support: RVO:68378271 Keywords : semi-insulating GaAs * metal-semiconductor contact * interface * work function * electron transport * XPS Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.387, year: 2016

  4. Effect of the Ignition Method on the Extinction Limit for a Flame Spreading over Electric Wire Insulation

    DEFF Research Database (Denmark)

    Mitsui, Fumiya; Nagachi, Masashi; Citerne, Jean-Marie

    Flame spread experiments with wire insulation were conducted in microgravity (parabolic flights) and in normal gravity to understand the effect of the ignition condition on the Limiting Oxygen Concentration (LOC) for an opposed air flow condition of 100 mm/s (typical flow velocity on ISS). Both t...

  5. Evaluating standard airborne sound insulation measures in terms of annoyance, loudness, and audibility ratings.

    Science.gov (United States)

    Park, H K; Bradley, J S

    2009-07-01

    This paper reports the results of an evaluation of the merits of standard airborne sound insulation measures with respect to subjective ratings of the annoyance and loudness of transmitted sounds. Subjects listened to speech and music sounds modified to represent transmission through 20 different walls with sound transmission class (STC) ratings from 34 to 58. A number of variations in the standard measures were also considered. These included variations in the 8-dB rule for the maximum allowed deficiency in the STC measure as well as variations in the standard 32-dB total allowed deficiency. Several spectrum adaptation terms were considered in combination with weighted sound reduction index (R(w)) values as well as modifications to the range of included frequencies in the standard rating contour. A STC measure without an 8-dB rule and an R(w) rating with a new spectrum adaptation term were better predictors of annoyance and loudness ratings of speech sounds. R(w) ratings with one of two modified C(tr) spectrum adaptation terms were better predictors of annoyance and loudness ratings of transmitted music sounds. Although some measures were much better predictors of responses to one type of sound than were the standard STC and R(w) values, no measure was remarkably improved for predicting annoyance and loudness ratings of both music and speech sounds.

  6. Experimental Evaluation and Comparison of Thermal Conductivity of High-Voltage Insulation Materials for Vacuum Electronic Devices

    Science.gov (United States)

    Suresh, C.; Srikrishna, P.

    2017-07-01

    Vacuum electronic devices operate with very high voltage differences between their sub-assemblies which are separated by very small distances. These devices also emit large amounts of heat that needs to be dissipated. Hence, there exists a requirement for high-voltage insulators with good thermal conductivity for voltage isolation and efficient heat dissipation. However, these voltage insulators are generally poor conductors of heat. In the present work, an effort has been made to obtain good high-voltage insulation materials with substantial improvement in their thermal conductivity. New mixtures of composites were formed by blending varying percentages (by volumes) of aluminum nitride powders with that of neat room-temperature vulcanizing (RTV) silicone elastomer compound. In this work, a thermal conductivity test setup has been devised for the quantification of the thermal conductivity of the insulators. The thermal conductivities and high-voltage isolation capabilities of various blended composites were quantified and were compared with that of neat RTV to evaluate the relative improvement.

  7. Potential and electric-field distributions around an ice-covered post-type insulator; Distributions du potentiel et du champ electrique le long d'un isolateur de poste recouvert de glace

    Energy Technology Data Exchange (ETDEWEB)

    Volat, C.; Farzaneh, M. [Quebec Univ., Chicoutimi, PQ (Canada). Industrial Chair on Atmospheric Icing of Power Network Equipment

    2006-10-01

    This study investigated the phenomenon preceding a flashover on an ice-covered post-type insulator during a melting period. The potential and electric-field distributions along the insulator were calculated in an effort to solve the problem of power outages in cold, remote regions and to find the location of faulty equipment during icing events. It was shown that ice accumulation can significantly affect the performance of electrical insulators and that new and better insulators should be considered for cold climate regions. This study included a laboratory component in which an ice-covered insulator was simulated and experimentally validated using a commercial software based on the boundary element method. The simulation considered the presence of a conducting water film at the ice surface, the shedding of ice deposits, and the presence of a partial electric arc along an air gap. It was concluded that the water film, the number of internal voids, and the duration and presence of partial arcs has a considerable influence on the insulators. 22 refs., 7 tabs., 16 figs.

  8. Insulator for laser housing

    Science.gov (United States)

    Duncan, David B.

    1992-01-01

    The present invention provides a heat-resistant electrical insulator adapted for joining laser housing portions, which insulator comprises: an annulus; a channel in the annulus traversing the circumference and length of the housing; at least two ports, each communicating with the channel and an outer surface of the housing; and an attachment for securely attaching each end of the annulus to a laser housing member.

  9. Insulation fact sheet

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-08-01

    Electricity bills, oil bills, gas bills - all homeowners pay for one or more of these utilities, and wish they paid less. Often many of us do not really know how to control or reduce our utility bills. We resign ourselves to high bills because we think that is the price we have to pay for a comfortable home. We encourage our children to turn off the lights and appliances, but may not recognize the benefits of insulating the attic. This publication provides facts relative to home insulation. It discusses where to insulate, what products to use, the decision making process, installation options, and sources of additional information.

  10. Insulation coordination in distribution liveline maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Gela, G.; Balpinarli, M. (Dept. of Electrical Engineering, The Ohio State Univ., Columbus, OH (US))

    1988-10-01

    Insulation coordination principles are applied in this paper to assess the expected performance of distribution liveline maintenance equipment. Rubber gloves are used as an example. Breakdown probability distributions for Class II, III, and IV gloves are given for AC and slow-front surge voltages. Available (although scarce) data on observed surge magnitudes in sample distribution systems are quoted. Although quantitative evaluation of the risk of failure of liveline maintenance equipment cannot be performed due to insufficient data on surge performance of distribution systems, some qualitative conclusions can be derived. Based on available glove breakdown voltage values (electric strength) and in-service surge magnitudes (electric stress), it is apparent that flexible liveline maintenance equipment should be able to perform without failure. Additional extensive data base on electric stresses (surges) in distribution systems is needed for quantitative insulation coordination studies.

  11. Strongly correlated material under voltage: The electrical breakdown in V{sub 2}O{sub 3} at the insulator to metal transition

    Energy Technology Data Exchange (ETDEWEB)

    Guenon, Stefan; Wang, Siming; Ramirez, Juan Gabriel; Schuller, Ivan K. [Department of Physics and Center for Advanced Nanoscience, University of California, San Diego (United States); Scharinger, Sebastian; Koelle, Dieter; Kleiner, Reinhold [Physikalisches Institut and Center for Collective Quantum Phenomena and their Applications in LISAplus, Universitaet Tuebingen (Germany)

    2013-07-01

    We have investigated the electrical properties of a V{sub 2}O{sub 3} thin film micro bridge. Discontinuous jumps to lower voltages in the current voltage characteristic (IV) followed by an approximately constant voltage progression for high currents indicate an electrical breakdown of the device. In addition, the IV curves show hysteresis and a training effect, i.e. the subsequent IV loops are different from the first IV loop after thermal cycling. Low temperature scanning electron microscopy (LTSEM) reveals that the electrical breakdown over the whole device is caused by the formation of electro-thermal domains (ETDs), i.e. the current and temperature redistribution. On the contrary, at the nanoscale, the electrical breakdown causes the insulator to metal transition of individual domains. In a numerical model we considered these domains as a network of resistors and we were able to reproduce the electro-thermal breakdown as well as the hysteresis and the training effect in the IVs.

  12. Performance Evaluation Tests of Insulated Pressure Vessels for Vehicular Hydrogen Storage

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, S M; Martinez-Frias, J; Espinoza-Loza, F

    2002-03-01

    Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen or ambient-temperature compressed hydrogen. This flexibility results in multiple advantages with respect to compressed hydrogen tanks or low-pressure liquid hydrogen tanks. Our work is directed at verifying that commercially available aluminum-lined, fiber-wrapped pressure vessels can be safely used to store liquid hydrogen. A series of tests have been conducted, and the results indicate that no significant vessel damage has resulted from cryogenic operation. Future activities include a demonstration project in which the insulated pressure vessels will be installed and tested on two vehicles. A draft standard will also be generated for certification of insulated pressure vessels.

  13. Temperature and electric field stabilities of dielectric and insulating properties for c-axis-oriented CaBi4Ti4O15 films

    Science.gov (United States)

    Kimura, Junichi; Takuwa, Itaru; Matsushima, Masaaki; Yasui, Shintaro; Yamada, Tomoaki; Funakubo, Hiroshi

    2013-07-01

    Temperature and electric field dependencies of the dielectric and insulating properties of (001)-oriented epitaxial CaBi4Ti4O15 films grown on (100)cSrRuO3//(100)SrTiO3 substrates were investigated and compared with those of conventional (100)-oriented epitaxial (Ba0.3Sr0.7)TiO3 and SrTiO3 films. All films showed negative temperature dependency of the capacitance from 25 to 500 °C, and their changes were -18%, -83%, and -58% for CaBi4Ti4O15, (Ba0.3Sr0.7)TiO3, and SrTiO3 films, respectively. Smaller change of the capacitance against dc electric field was also observed for CaBi4Ti4O15 films. Moreover, the maximum leakage current density of CaBi4Ti4O15 films measured at ±100 kV/cm was below 10-3 A/cm2 up to 500 °C, which was smaller than those of (Ba0.3Sr0.7)TiO3 and SrTiO3 films. These results indicate that (001)-oriented CaBi4Ti4O15 films are a useful candidate as the capacitor material applicable for the high temperature use because of its high stability against temperature and an electric field as well as the good insulating characteristics.

  14. Insulation Coordination of Arcing Horns on HVDC Electrode Lines: Protection Performance Evaluation, Influence Factors and Improvement Method

    Directory of Open Access Journals (Sweden)

    Xiandong Li

    2018-02-01

    Full Text Available Arcing horns are widely used in high voltage overhead lines to protect insulator strings from being destroyed by the free burning arcs caused by lightening faults. In this paper, we focus on the insulation coordination of arcing horns on the electrode lines of a 5000 MW, ±800 kV high voltage direct current (HVDC system. The protection performance of arcing horns are determined by the characteristics of not only the external system but also the fault arc. Therefore, the behaviors and characteristics of long free burning arcs are investigated by the experiments at first. In order to evaluate the protection performance of arcing horns, the static stability criterion U-I characteristic method is introduced. The influence factors on the protection performance of arcing horns are analyzed theoretically. Finally, the improvement methods for the protection performance of arcing horns are proposed, and the diversified configuration strategy of arcing horns is recommended for cost saving.

  15. Performance Evaluation of A Low Heat Rejection Diesel Engine for Different Insulation Levels

    Directory of Open Access Journals (Sweden)

    Can Haşimoğlu

    2010-01-01

    Full Text Available This experimental study focuses on investigating of effects of low heat rejection engine application to a diesel engine at different insulation levels. For this purpose cylinder head and valves of the test engine were thermally insulated with yttria-stabilized zirconia (Y2O3–ZrO2 layer at first stage. Then in addition to cylinder head and valves, pistons of the test engine were coated with the same material. Brake specific fuel consumption (BSFC, exhaust gas temperature (EGT, brake thermal efficiency and volumetric efficiency of the test engine were investigated for two different insulation levels. After the engine tests it was determined that BSFC was improved by 4 - 7.1 %, EGT was increased by 3.5 - 6.8 %, brake thermal efficiency was improved by 4.1-7.9 % and volumetric efficiency was increased by 0.9 - 2.6 % with LHR application. It was also determined that these improvements in engine performance are proportional with the insulation levels of the test engine.

  16. The empirical evaluation of thermal conduction coefficient of some liquid composite heat insulating materials

    Science.gov (United States)

    Anisimov, M. V.; Rekunov, V. S.; Babuta, M. N.; Bach Lien, Nguyen Thi Hong

    2016-02-01

    We experimentally determined the coefficients of thermal conductivity of some ultra thin liquid composite heat insulating coatings, for sample #1 λ = 0.086 W/(m·°C), for sample #2 λ = 0.091 W/(m·°C). We performed the measurement error calculation. The actual thermal conduction coefficient of the studied samples was higher than the declared one. The manufactures of liquid coatings might have used some "ideal" conditions when defining heat conductivity in the laboratory or the coefficient was obtained by means of theoretical solution of heat conduction problem in liquid composite insulating media. However, liquid insulating coatings are of great interest to builders, because they allow to warm objects of complex geometric shapes (valve chambers, complex assemblies, etc.), which makes them virtually irreplaceable. The proper accounting of heating qualities of paints will allow to avoid heat loss increase above the specified limits in insulated pipes with heat transfer materials or building structures, as well as protect them from possible thawing in the period of subzero weather.

  17. Evaluation of Electric Power Procurement Strategies by Stochastic Dynamic Programming

    Science.gov (United States)

    Saisho, Yuichi; Hayashi, Taketo; Fujii, Yasumasa; Yamaji, Kenji

    In deregulated electricity markets, the role of a distribution company is to purchase electricity from the wholesale electricity market at randomly fluctuating prices and to provide it to its customers at a given fixed price. Therefore the company has to take risk stemming from the uncertainties of electricity prices and/or demand fluctuation instead of the customers. The way to avoid the risk is to make a bilateral contact with generating companies or install its own power generation facility. This entails the necessity to develop a certain method to make an optimal strategy for electric power procurement. In such a circumstance, this research has the purpose for proposing a mathematical method based on stochastic dynamic programming and additionally considering the characteristics of the start-up cost of electric power generation facility to evaluate strategies of combination of the bilateral contract and power auto-generation with its own facility for procuring electric power in deregulated electricity market. In the beginning we proposed two approaches to solve the stochastic dynamic programming, and they are a Monte Carlo simulation method and a finite difference method to derive the solution of a partial differential equation of the total procurement cost of electric power. Finally we discussed the influences of the price uncertainty on optimal strategies of power procurement.

  18. The influence of strong electric fields on the DC conductivity of the composite cellulose, insulating oil, and water nanoparticles

    Science.gov (United States)

    Kierczyński, Konrad; Żukowski, Paweł

    2016-12-01

    The paper presents investigated the dependencies of DC conductivity electrical pressboard impregnated insolating oil of moisture content and electric field strength. The studies were conducted for measuring temperature in the range of 20 °C to 80 °C and the electric field intensity in the range of 10 kV/m to 1000 kV/m. With approximate waveforms in double logarithmic coordinates conductivity depending on the intensity of the electric field exponential function determined coefficients of determination R2. The value of this ratio is close to unity, which provides high accuracy measurements of conductivity and the exact stability and temperature measurements. It was found that changes in the electric field intensity will decrease the activation energy of conductivity of about 0.01 eV, thus increasing the DC conductivity of about 1.5 times.

  19. Evaluating Permeability Enchancement Using Electrical Techniques

    Energy Technology Data Exchange (ETDEWEB)

    John W. Pritchett

    2008-09-01

    Enhanced Geothermal Systems (EGS) development projects involve the artificial stimulation of relatively impermeable high-temperature underground regions (at depths of 2-4 kilometers or more) to create sufficient permeability to permit underground fluid circulation, so that hot water can be withdrawn from production wells and used to generate electric power. Several major research projects of this general type have been undertaken in the past in New Mexico (Fenton Hill), Europe, Japan and Australia. Recent U.S. activities along these lines focus mainly on stimulating peripheral areas of existing operating hydrothermal fields rather than on fresh 'greenfield' sites, but the long-term objective of the Department of Energy's EGS program is the development of large-scale power projects based on EGS technology (MIT, 2006; NREL, 2008). Usually, stimulation is accomplished by injecting water into a well at high pressure, enhancing permeability by the creation and propagation of fractures in the surrounding rock (a process known as 'hydrofracturing'). Beyond just a motivation, low initial system permeability is also an essential prerequisite to hydrofracturing. If the formation permeability is too high, excessive fluid losses will preclude the buildup of sufficient pressure to fracture rock. In practical situations, the actual result of injection is frequently to re-open pre-existing hydrothermally-mineralized fractures, rather than to create completely new fractures by rupturing intact rock. Pre-existing fractures can often be opened using injection pressures in the range 5-20 MPa. Creation of completely new fractures will usually require pressures that are several times higher. It is preferable to undertake development projects of this type in regions where tectonic conditions are conducive to shear failure, so that when pre-existing fractures are pressurized they will fail by shearing laterally. If this happens, the fracture will often stay open

  20. Marginal electricity and environmental evaluation of electricity; Marginalel och miljoevaerdering av el

    Energy Technology Data Exchange (ETDEWEB)

    Skoeldberg, Haakan; Unger, Thomas; Olofsson, Mattias

    2006-08-15

    In many environmental-impact analyses and assessments it is inevitable to estimate the environmental consequences of electricity use and electricity generation. In most cases, this is done in order to confront different alternatives with one another and compare their environmental effects. Hence, it is the effects of a change that one wants to illustrate. There are a number of approaches that can form the basis for such environmental evaluations. This project has been carried out in order to find a structure in the conceptions of environmental evaluations of electricity and to present different approaches for such evaluations. In particular, the concept of marginal electricity has been of central interest in this project. By marginal electricity we refer to the last used unit of electricity at any given point of time, which, generally, is supplied with the most costly means of generation in the generation merit order. An important part of the project has been a seminar where nine different speakers presented their views on the subject. In a concluding panel debate, the speakers participated in a discussion with the audience. The principles for environmental evaluation often appear to be chosen to fit the alternative that one is favouring. Those who want to achieve reduced electricity use preferably use marginal data for electricity, while those who are in favour of increased electricity use preferably choose average data. The choice of environmental evaluation principle has a decisive impact on the results. The most important reason for this is the dramatic difference between average and marginal data in the Swedish and Nordic electricity generation systems. It is obvious that there is a lack of consensus regarding which principle for environmental evaluation of electricity that should be used. In the initial phase of this project eight different principles were identified. Most people, but far from all, have the opinion that some type of marginal approach should

  1. 13. SNPTEE: Brazilian seminar on electric power production and transmission. Group 11: overvoltage, insulation coordination and interferences (GSI); 13. SNPTEE: Seminario nacional de producao e transmissao de energia eletrica. Grupo 11: sobretensoes, coordenacao de isolamento e interferencias (GSI)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    This book collects the works presented during the 13{sup th} national seminar on electric power generation and transmission which took place in Camboriu, Santa Catarina State - South Brazil, in 1995. The Group 11 discussed over voltages, insulation coordination and interferences giving special emphasis to: electric power systems design, operation, controlling and optimization; as well as automation and safety systems. The existing situation in Brazil is presented and discussed as well as future trends and perspectives. Several case studies are presented

  2. Interior insulation – Experimental investigation of hygrothermal conditions and damage evaluation of solid masonry façades in a listed building

    DEFF Research Database (Denmark)

    Odgaard, Tommy; Bjarløv, Søren Peter; Rode, Carsten

    2018-01-01

    % on the outside, while the insulated wall showed uniformly distributed values around 80%. The risk of moisture-induced damage was evaluated based on mathematical models for mould and decay of wood, visual inspection for frost and mould, and on-site measurements for presence of mould spores. The damage evaluation......Exterior walls in historic multi-storey buildings compared to walls in modern buildings have low thermal resistance, resulting in high energy loss and cold surfaces/floors in cold climates. When restrictions regarding alteration of the exterior appearance exist, interior insulation might...... be the only possibility to increase occupant comfort. This paper describes an investigation of the hygrothermal influence when applying 100 mm of diffusion open interior insulation to a historic multi-storey solid masonry spandrel. The dormitory room with the insulated spandrel had a normal indoor climate...

  3. High-speed electrical motor evaluation

    Energy Technology Data Exchange (ETDEWEB)

    1989-02-03

    Under this task, MTI conducted a general review of state-of-the-art high-speed motors. The purpose of this review was to assess the operating parameters, limitations and performance of existing motor designs, and to establish commercial sources for a motor compatible with the requirements of the Brayton-cycle system. After the motor requirements were established, a list of motor types, manufacturers and designs capable of achieving the requisite performance was compiled. This list was based on an in-house evaluation of designs. Following the establishment of these options, a technical evaluation of the designs selected was conducted. In parallel with their evaluations, MTI focused on the establishment of commercial sources.

  4. Suppression of metal-insulator transition in VO2 by electric field-induced oxygen vacancy formation

    National Research Council Canada - National Science Library

    Jeong, Jaewoo; Aetukuri, Nagaphani; Graf, Tanja; Schladt, Thomas D; Samant, Mahesh G; Parkin, Stuart S P

    2013-01-01

    .... We found that electrolyte gating of VO(2) leads not to electrostatically induced carriers but instead to the electric field-induced creation of oxygen vacancies, with consequent migration of oxygen from the oxide film into the ionic liquid...

  5. Evaluation of kraft paper chemical byproducts in insulating mineral oil of energized transformers; Avaliacao de subprodutos quimicos de papel tipo kraft em oleo mineral isolante de transformadores energizados

    Energy Technology Data Exchange (ETDEWEB)

    Portella, Mariana d' Orey Gaivao; Portella, Kleber Franke; Swinka Filho, Vitoldo; Silva, Guilherme Cunha da; Stocco, Guilherme Barrachina; Batista, Douglas Antonio; Sabec, Daiane Cristina; Deger, Claudio Adriano [Instituto de Tecnologia para o Desenvolvimento (LATEC), Curitiba, PR (Brazil)], E-mails: mariana.portella@lactec.org.br, portella@laclec.org.br; Andreoli, Mario Carlos [Centro de Transmissao de Energia Eletrica Paulista (CTEEP), Sao Paulo, SP (Brazil)], E-mail: mandreoli@cteep.com.br

    2011-10-15

    The insulating paper is a major determinant of the remaining lifetime of an electrical transformer, since it is not possible to analyse or replace this equipment during operation. However, using the quantification of the furanic compounds concentration formed in mineral oil, it is possible to infer about the quality of the material, confirming the presence of degradation. Given the existence of new kinds of solid insulation, this research aimed at studying a new analytical methodology, using the techniques of liquid chromatography with mass detection of these substances in order to increase the reliability of the results, assisting the preventive maintenance. (author)

  6. Fuel Cell Electric Vehicle Evaluation; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Jennifer; Sprik, Sam; Ainscough, Chris; Saur, Genevieve

    2015-06-10

    This presentation provides a summary of NREL's FY15 fuel cell electric vehicle evaluation project activities and accomplishments. It was presented at the U.S. Department of Energy Hydrogen and Fuel Cells Program 2015 Annual Merit Review and Peer Evaluation Meeting on June 10, 2015, in Arlington, Virginia.

  7. Electrocardiographic Evaluation of Structural and Electrical ...

    African Journals Online (AJOL)

    DATONYE ALASIA

    electrocardiography. The aim of this study is to evaluate the hypertension related abnormalities on the electrocardiograph of patients with untreated hypertension. Methodology: A detailed prospective analysis of the electrocardiographic tracing of all patients with untreated essential hypertension at first presentation over a ...

  8. Needle-Bonded Electromagnetic Shielding Thermally Insulating Nonwoven Composite Boards: Property Evaluations

    Directory of Open Access Journals (Sweden)

    Jia-Horng Lin

    2016-10-01

    Full Text Available Complicated environmental problems inevitably arise when technology advances. One major environmental problem is the presence of electromagnetic radiation. Long-term exposure to electromagnetic radiation can damage people’s health in many ways. Therefore, this study proposes producing composite boards with electromagnetic shielding effectiveness and thermal insulation by utilizing the structures and properties of materials. Different combinations of flame-retardant polyester fiber (FR fiber, recycled far-infrared polyester fiber (FI fiber, and 4D low-melting-point fibers (LM fiber were made into flame-retardant and thermally insulating matrices. The matrices and carbon fiber (CF woven fabric in a sandwich-structure were needle-punched in order to be tightly compact, and then circularly heat dried in order to have a heat set and reinforced structure. The test results indicate that Polyester (PET/CF composite boards are mechanically strong and have thermal insulation and electromagnetic shielding effectiveness at a frequency between 0.6 MHz and 3 GHz.

  9. Evaluation of thermal insulation and mechanical properties of waste rubber/natural rubber composite

    Directory of Open Access Journals (Sweden)

    M.M. Abdel Kader

    2012-04-01

    Full Text Available The influences of waste rubber loading on mechanical and thermal conductivity properties were investigated for NR composite. An experimental investigation was carried out to obtain low cost construction material with desirable mechanical and thermal insulation properties. Natural rubber was loaded with different concentrations of waste rubber (200, 400, 600, 800, and 1000 phr. The addition of waste rubber leads to a slight increase in thermal conductivity values of composites but it still lies around range of thermal insulating materials. Also addition of waste rubber leads to improvement of mechanical properties of composites. The crosslink density of NR composite increases with the increase of waste rubber loading until 600 phr and after that it decreases due to the stronger the rubber–filler interaction. This leads to the decrease of the swelling index that has the opposite trend of crosslink density. So, the sample with 600 phr waste rubber is considered the optimum concentration from the swelling measurement. Filler loading results in pronounced increase in the tensile modulus and decease in the elongation at fracture which reflects the reinforcement effect of the filler. The yield stress increases with waste rubber loading increment. This delays the permanent disruption of matrix morphology. So, the optimum concentration which is 600 phr waste rubber loading agrees with the swelling and mechanical measurements which has desirable thermal insulation and high mechanical properties and decreases the cost of materials to 82% of the NR cost.

  10. A comparative study of Mg and Pt contacts on semi-insulating GaAs: Electrical and XPS characterization

    Energy Technology Data Exchange (ETDEWEB)

    Dubecký, F., E-mail: elekfdub@savba.sk [Institute of Electrical Engineering, SAS, Dúbravská cesta 9, Bratislava, SK-84104 (Slovakia); Kindl, D.; Hubík, P. [Institute of Physics CAS, v.v.i., Cukrovarnická 10, CZ-16200 Prague (Czech Republic); Mičušík, M. [Polymer Institute, SAS, Dúbravská cesta 9, Bratislava, SK-84541 (Slovakia); Dubecký, M. [Department of Physics, Faculty of Science, University of Ostrava, 30. dubna 22, CZ-70103 Ostrava 1 (Czech Republic); Boháček, P.; Vanko, G. [Institute of Electrical Engineering, SAS, Dúbravská cesta 9, Bratislava, SK-84104 (Slovakia); Gombia, E. [IMEM-CNR, Parco area delle Scienze 37/A, Parma, I-43010 (Italy); Nečas, V. [Faculty of Electrical Engineering and Information Technology, SUT, Ilkovičova 3, Bratislava, SK-81219 (Slovakia); Mudroň, J. [Department of Electronics, Academy of Armed Forces, Demänová 393, Liptovský Mikuláš, SK-03106 (Slovakia)

    2017-02-15

    Highlights: • Explored were diodes with full-area low/high work function metal contacts on semi-insulating GaAs (S). • The Mg-S-Mg diode is promising for radiation detectors for its low high-field current. • The XPS analysis of Mg-S interface shows presence of MgO instead of Mg metal. - Abstract: We present a comparative study of the symmetric metal-SI GaAs-metal (M-S-M) diodes with full-area contacts on both device sides, in order to demonstrate the effect of contact metal work function in a straightforward way. We compare the conventional high work function Pt contact versus the less explored low work function Mg contact. The Pt-S-Pt, Mg-S-Mg and mixed Mg-S-Pt structures are characterized by the current-voltage measurements, and individual Pt-S and Mg-S contacts are investigated by the X-ray photoelectron spectroscopy (XPS). The transport measurements of Mg-S-Pt structure show a significant current decrease at low bias while the Mg-S-Mg structure shows saturation current at high voltages more than an order of magnitude lower with respect to the Pt-S-Pt reference. The phenomena observed in Mg-containing samples are explained by the presence of insulating MgO layer at the M-S interface, instead of the elementary Mg, as confirmed by the XPS analysis. Alternative explanations of the influence of MgO layer on the effective resistance of the structures are presented. The reported findings have potential applications in M-S-M sensors and radiation detectors based on SI GaAs.

  11. Evaluating the Mechanical Properties of Tomato Based on Electrical Conductivity

    Directory of Open Access Journals (Sweden)

    M Ghasemi

    2014-09-01

    Full Text Available Evaluation of mechanical and electrical properties of agricultural products plays an important role in equipment design and optimizing post-harvest operations. Among the crops, tomato and its products are the major processing industries in the world and its economic importance is increasing. Considering the importance of the quality and various post harvesting uses of tomato, the evaluation of mechanical properties including rupture force and deformation and the work done to establish the rupture of two tomato cultivars (Petoearly CH and Newton were studied under penetration test based on the electrical conductivity. These properties were measured at three levels of 1, 3 and 5 days after harvesting. The evaluated mechanical properties of both cultivars were decreased by increasing the storage time. Interaction of cultivar and time were significant at the 1% level, for all mechanical parameters except the deformation failure in both cultivars. The electrical conductivity of both cultivars was decreased by increasing the storage time. Interaction of cultivar and time on the electrical conductivity of both cultivars were significant at the 1% level. Significant relationships were found at the 1% level between electrical conductivity and mechanical properties except for deformation of Petoearly CH cultivar. Among the mechanical parameters, rupture forces and rupture works of both cultivars were highly correlated with the electrical conductivity.

  12. Electric double-layer transistor using layered iron selenide Mott insulator TI[Fe.sub.1.6][Se.sub.2

    National Research Council Canada - National Science Library

    Katase, Takayoshi; Hiramatsu, Hidenori; Kamiya, Toshio; Hosono, Hideo

    2014-01-01

    ... (AFM) insulating phases, and they have extremely high Neel transition temperatures. However, control of carrier doping into the parent AFM insulators has been difficult due to their intrinsic phase separation...

  13. Insulation commonality assessment (phase 1). Volume 2: Section 7.0 through 16.0. [evaluation of materials used for spacecraft thermal insulation

    Science.gov (United States)

    1973-01-01

    The heat transfer characteristics of various materials used for the thermal insulation of spacecraft are discussed. Techniques for conducting thermal performance analysis, structural performance analysis, and dynamic analysis are described. Processes for producing and finishing the materials are explained. The methods for determining reliability, system safety, materials tests, and design effectiveness are explained.

  14. TO STUDY AND ANALYSIS OF RTV SILICONE RUBBER INSULATOR OPERATED WITH VARIOUS TEMPERATURE

    OpenAIRE

    Dr. S. K. Mahobia

    2017-01-01

    The insulator are most important equipment in transmission Line, Distribution Line and electrical power plant. In this way the insulator are used with pin, insulator and pin are mounted on the frame, which is connected with the Grid power supply. The insulator has to separate of electrical power supply and structure, in this way we are used the high quality insulator.

  15. The impact of etched trenches geometry and dielectric material on the electrical behaviour of silicon-on-insulator self-switching diodes

    Energy Technology Data Exchange (ETDEWEB)

    Farhi, G; Charlebois, S A [Departement de genie electrique et genie informatique, et Institut interdisciplinaire d' innovation technologique (3IT), Universite de Sherbrooke, 2500, Boulevard de l' Universite, J1K 2R1, Sherbrooke, QC (Canada); Morris, D [Departement de physique et Institut interdisciplinaire d' innovation technologique (3IT), Universite de Sherbrooke, 2500, Boulevard de l' Universite, J1K 2R1, Sherbrooke, QC (Canada); Raskin, J-P, E-mail: ghania.farhi@usherbrooke.ca [Institute of Information and Communication Technologies, Electronics and Applied Mathematics (ICTEAM), Universite catholique de Louvain, Place du Levant, 3, B-1348 Louvain-la-Neuve (Belgium)

    2011-10-28

    Hole electrical transport in a p-doped nanochannel defined between two L-shape etched trenches made on a silicon-on-insulator substrate is investigated using a TCAD-Medici simulator. We study the impact of the etched trenches' geometry and dielectric filling materials on the current-voltage characteristics of the device. Carrier accumulation on frontiers defined by the trenches causes a modulation of the hole density inside the conduction channel as the bias voltage varies and this gives rise to a diode-like characteristic. For a 1.2 {mu}m-long channel, plots of the electric field distribution show that a nonlinear transport regime is reached at a moderate reverse and forward bias of {+-} 2 V. Plots of the carrier velocity along the conduction channel show that holes remain hot for a few hundreds of nm outside the nanometre-wide channel, at a bias of {+-} 10 V. Filling the etched trenches with a high-{kappa} dielectric material gives rise to a lower threshold voltage, V{sub th}. A similar decrease of V{sub th} is also achieved by reducing the longitudinal and/or the transverse trench width. Our simulation results provide useful design guidelines for future integrated self-switching-diode-based circuits.

  16. Evaluation of Unknown Tube Well Depth Using Electrical Resistivity Method

    Directory of Open Access Journals (Sweden)

    Zainal Abidin Mohd Hazreek

    2017-01-01

    Full Text Available Electrical resistivity method has increasingly adopted in engineering, environmental, mining and archaeological studies. Systematic and proper studies of unknown civil engineering structure evaluation particularly on tube well depth was rarely being established. Conventionally, camera test or string with weight approach has been used to evaluate unknown tube well depth thus exposed to several restriction due to its expensive and time consuming. Hence, this study focused on evaluation of unknown tube well depth using indirect test with particular reference to electrical resistivity method (ERM.A single spread line of electrical resistivity survey was performed using ABEM SAS 4000 equipment set based on Wenner and Pole-dipole array in line with the tube well position. Electrical resistivity raw data was processed using RES2DINV software producing electrical resistivity tomography (ERT of the subsurface profile studied. Then, electrical resistivity value (ERV obtained from RES2DINV analyses (ERT was extracted and analysed using plotted graph (depth versus ERV specifically at tube well position based on electrical resistivity spread line performed. It was found that both array have shown some good similarity results in term of tube well depth (20 m thus able to verify the result interpreted. Both array have shown some good similarity of ERV representing groundwater (ERV = 10 – 100 Ωm and soil with water (ERV > 100 Ωm at depth of 0 – 20 m and >20 m respectively. All those interpretation have shown good agreement based on verification thru established ERV of earth materials references, geological map and nearest available boreholes data. Hence, this study has shown that the application of ERM was applicable in evaluation of unknown tube well depth which efficient in term of cost, time and environmental sustainable.

  17. Cellulose Insulation

    Science.gov (United States)

    1980-01-01

    Fire retardant cellulose insulation is produced by shredding old newspapers and treating them with a combination of chemicals. Insulating material is blown into walls and attics to form a fiber layer which blocks the flow of air. All-Weather Insulation's founders asked NASA/UK-TAP to help. They wanted to know what chemicals added to newspaper would produce an insulating material capable of meeting federal specifications. TAP researched the query and furnished extensive information. The information contributed to successful development of the product and helped launch a small business enterprise which is now growing rapidly.

  18. Thermal insulator

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, R.; Asada, Y.; Matsuo, Y.; Mikoda, M.

    1985-07-16

    A thermal insulator comprises an expanded resin body having embedded therein an evacuated powder insulation portion which consists of fine powder and a container of film-like plastics or a film-like composite of plastics and metal for enclosing the powder. The resin body has been expanded by a Freon gas as a blowing agent. Since a Freon gas has a larger molecular diameter than the constituent gases of air, it is less likely to permeate through the container than air. Thus present invention provides a novel composite insulator which fully utilizes the benefits of vacuum insulation without necessitating a strong and costly material for a vacuum container.

  19. A Method of Insulator Detection from Aerial Images

    Directory of Open Access Journals (Sweden)

    Yongjie Zhai

    2014-08-01

    Full Text Available With increased image processing and sensor technologies, it is possible for photogrammetrists to monitor the status of electrical power infrastructures. Identifying and extracting insulators from complex background have great potential in automatic power grid surveillance on board unmanned aerial vehicles. This paper proposes an improved method to automatically extract the insulators from aerial images. A 3D model is introduced into the existing algorithms to obtain samples of insulators, which are Haar features and AdaBoost. Finally, in order to evaluate the performances, we compare our 3D model-based method with the existing methods that does not use 3D model to show the performance improvement. The experimental results demonstrate that the proposed method is able to successfully extract the insulators from aerial images with an increased average detection ratio to 83 %.

  20. A clamp fixture with interdigital capacitive sensor for in situ evaluation of wire insulation

    Science.gov (United States)

    Sheldon, Robert T.; Bowler, Nicola

    2014-02-01

    An interdigital capacitive sensor has been designed and optimized for testing aircraft wires by applying a quasinumerical model developed and reported previously. The sensor consists of two patches of interdigitated electrodes, connected by a long signal bus strip, that are intended to conform to two sides of an insulated wire. The electrodes are deposited using photolithography upon a 25.4-μm-thick Kapton® polyimide film. The two electrode patches are attached to the two jaws of a plastic spring-loaded clamp, with each jaw having a milled groove designed such that the electrodes conform to the curved surface of the insulated wire. An SMA connector and cable connect between the electrodes on the clamp and an LCR meter. Segments of pristine M5086/2 aircraft wire, each 10 cm long, were immersed in fluids commonly found in aircraft environments, to cause accelerated chemical degradation. The effects of Jet A fuel, deicing fluid, hydraulic fluid, aircraft cleaner, isopropyl alcohol and distilled water were studied. The frequency-dependent capacitance and dissipation factor of one pristine wire segment and of those degraded in the six fluid environments were measured within the frequency range 100 Hz to 1 MHz. Significant changes in capacitance and dissipation factor were observed for all degraded wires, compared with results for the pristine sample, suggesting the feasibility of detecting insulation degradation in the field. The results were also consistent with those of a similar experiment performed on sheets of Nylon 6, the material that comprises the outermost layer of M5086/2 wire.

  1. Combustion Products Evaluation from Hull Insulation Materials Coated with Fire Retardant Paints.

    Science.gov (United States)

    1980-09-08

    Bureau of Standards, Report No. NBSIR 78-1584 of May 1979. 2. P.A. Tatem, "Production of Gaseous Combustion Products from Insulating Foam ( Armaflex -FR...Letter Report 6180-102:PAT:bh of 15 May 1975. 6. P.A. Tatem, I.T. Cheng and F.W. Williams, "Toxic Product Evolution from Armaflex -FR and Armaflex -FR...I.T. Cheng and F.W. Williams, "Toxic Product Evolution from Armaflex -FR Coated with Fire Retardant Paints, Part I; forwarding of information on," NRL

  2. Reliability evaluation of deregulated electric power systems for planning applications

    Energy Technology Data Exchange (ETDEWEB)

    Ehsani, A. [Electrical Engineering Department, Sharif University of Technology, PO Box 11365-8639, Tehran (Iran, Islamic Republic of)], E-mail: aehsani80@yahoo.com; Ranjbar, A.M. [Electrical Engineering Department, Sharif University of Technology, PO Box 11365-8639, Tehran (Iran, Islamic Republic of); Jafari, A. [Niroo Research Institute, PO Box 14665/517, Tehran (Iran, Islamic Republic of); Fotuhi-Firuzabad, M. [Electrical Engineering Department, Sharif University of Technology, PO Box 11365-8639, Tehran (Iran, Islamic Republic of)

    2008-10-15

    In a deregulated electric power utility industry in which a competitive electricity market can influence system reliability, market risks cannot be ignored. This paper (1) proposes an analytical probabilistic model for reliability evaluation of competitive electricity markets and (2) develops a methodology for incorporating the market reliability problem into HLII reliability studies. A Markov state space diagram is employed to evaluate the market reliability. Since the market is a continuously operated system, the concept of absorbing states is applied to it in order to evaluate the reliability. The market states are identified by using market performance indices and the transition rates are calculated by using historical data. The key point in the proposed method is the concept that the reliability level of a restructured electric power system can be calculated using the availability of the composite power system (HLII) and the reliability of the electricity market. Two case studies are carried out over Roy Billinton Test System (RBTS) to illustrate interesting features of the proposed methodology.

  3. Electrical Resistivity of Concrete for Durability Evaluation: A Review

    Directory of Open Access Journals (Sweden)

    Pejman Azarsa

    2017-01-01

    Full Text Available Degradation processes in reinforced concrete structures that affect durability are partially controlled by transport of aggressive ions through the concrete microstructure. Ions are charged and the ability of concrete to hold out against transfer of ions greatly relies on its electrical resistivity. Hence, a connection could be expected between electrical resistivity of concrete and the deterioration processes such as increase in permeability and corrosion of embedded steel. Through this paper, an extensive literature review has been done to address relationship between concrete electrical resistivity and its certain durability characteristics. These durability characteristics include chloride diffusivity and corrosion of reinforcement as these have major influence on concrete degradation process. Overall, there exists an inverse or direct proportional correlation between these parameters. Evaluated results, from measuring the concrete electrical resistivity, can also be used as a great indicator to identify early age characteristics of fresh concrete and for evaluation of its properties, determination of moisture content, connectivity of the micropores, and even condition assessment of in-service structures. This paper also reviews and assesses research concerning the influential parameters such as environmental conditions and presence of steel rebar and cracks on measuring electrical resistivity of concrete. Moreover, concrete resistivity concept, application, and its various measurement techniques are introduced.

  4. Evaluation of the electrical conductivity and corrosion resistance for layers deposited via sputtering on stainless steel

    Science.gov (United States)

    Blanco, J.; Salas, Y.; Jiménez, C.; Pineda, Y.; Bustamante, A.

    2017-12-01

    In some Engineering fields, we need that conductive materials have a mechanic performance and specific electrical for that they maintain conditions or corrosive attack if they are in the environment or if they are closed structure. The stainless steels have an inert film on their surface and it has the function to act in contrast to external agents who generates the corrosion, especially for stings, spoiling the film until to fail. We found a solution taking into account the electrical performance and the anticorrosive; into the process we put recovering of specific oxides on, stainless steel using the method of sputtering with Unbalanced Magnetron, (UBM) varying the oxygen in the reactive environment. The coating obtained had a thickness one micron approximately and we saw on serious structural uniformity [1]. The corrosion resistance was evaluated through the potentiodynamics polarization and electrochemical spectroscopy impedance in NACL according to the standard. The cathode protection is the most important method employed for the corrosion prevention of metallic structures in the soil or immersed on the water. The electrical resistivity was evaluated with the four points methods and it showed a behaviour of diode type in some substrates with a threshold potential in several volts. We noticed a simple resistance solution when it was analysed in the Nyquist graphics whit the Electrochemical Impedance Spectroscopy technique. With on equivalent circuit, for this reason we determinate a variation in the corrosion speed in almost two orders of magnitude when we analysed the potentiodynamics curve by Tafel approximation. The data obtained and analysed show that this type of surface modification maintains the conductivity condition at the interface, improving the resistance in relation whit the corrosion of these elements where the recovering allowed the ionic flow wished for overcoming threshold voltage, acting as an insulator in different cases.

  5. EVALUATION OF THE APPLICATION OF A THERMAL INSULATION SYSTEM: IN-SITU COMPARISSON OF SEASONAL AND DAILY CLIMATIC FLUCTUATIONS

    Directory of Open Access Journals (Sweden)

    Jan Fořt

    2017-06-01

    Full Text Available The current outdated state of many institutional and administrative buildings in the EU region poses a significant burden from the energy sustainability point of view. According to the contemporary EU requirements on the energy efficiency of buildings maintenance, an evaluation of performed improvements is essential for the assessment of expended investments. This paper describes the effect of building envelope reconstruction works consisting in the installation of a thermal insulation system. Here, a long-term continuous monitoring is used for the extensive assessment of the seasonal and daily temperature and relative humidity fluctuations. The obtained results include temperature and relative humidity profiles in the wall cross-section as a response to the changing exterior climatic conditions. The analysis of measured data reveals substantial improvements in thermal stability of the analyzed wall during temperature peaks. While the indoor temperatures exceeding 28 °C are recorded during summer before application of the thermal insulation layer, the thermal stability of the indoor environment is distinctly upgraded after performed improvements. Based on the complex long-term monitoring, a relevant experience is gained for the future work on energy sustainability and fulfilment of the EU directives.

  6. Metal-insulator transition in tin doped indium oxide (ITO) thin films: Quantum correction to the electrical conductivity

    OpenAIRE

    Deepak Kumar Kaushik; K. Uday Kumar; Subrahmanyam, A

    2017-01-01

    Tin doped indium oxide (ITO) thin films are being used extensively as transparent conductors in several applications. In the present communication, we report the electrical transport in DC magnetron sputtered ITO thin films (prepared at 300 K and subsequently annealed at 673 K in vacuum for 60 minutes) in low temperatures (25-300 K). The low temperature Hall effect and resistivity measurements reveal that the ITO thin films are moderately dis-ordered (kFl∼1; kF is the Fermi wave vector and l ...

  7. Statistical and electrical properties of the conduction electrons of a metal nanosphere in the region of metal-insulator transition

    OpenAIRE

    Datsyuk, Vitaly V; Ivanytska, Iryna V

    2014-01-01

    Statistical and electrical properties of the conduction electrons of a silver or gold sphere with a radius from 1 to 2 nm are shown to differ drastically from the properties of electrons in a bulk metal sample. If the radius of a noble metal sphere decreases from 10 to 1 nm, its conductivity oscillates around the bulk metal value with increasing amplitude and drops at the 'magic’ numbers of electrons. These numbers are equal to 186, 198, 254, 338, 440, 556, 676, 832, 912, 1,284, 1,502, and 1,...

  8. Religion insulates ingroup evaluations: the development of intergroup attitudes in India.

    Science.gov (United States)

    Dunham, Yarrow; Srinivasan, Mahesh; Dotsch, Ron; Barner, David

    2014-03-01

    Research on the development of implicit intergroup attitudes has placed heavy emphasis on race, leaving open how social categories that are prominent in other cultures might operate. We investigate two of India's primary means of social distinction, caste and religion, and explore the development of implicit and explicit attitudes towards these groups in minority-status Muslim children and majority-status Hindu children, the latter drawn from various positions in the Hindu caste system. Results from two tests of implicit attitudes find that caste attitudes parallel previous findings for race: higher-caste children as well as lower-caste children have robust high-caste preferences. However, results for religion were strikingly different: both lower-status Muslim children and higher-status Hindu children show strong implicit ingroup preferences. We suggest that religion may play a protective role in insulating children from the internalization of stigma. © 2013 John Wiley & Sons Ltd.

  9. Evaluation of Silicon-on-Insulator HTOP-01 Operational Amplifier for Wide Temperature Operation

    Science.gov (United States)

    Patterson, Richard; Hammoud, Ahmad; Elbuluk, Malik

    2008-01-01

    Electronics capable of operation under extreme temperatures are required in many of NASA space exploration missions. Aerospace and military applications, as well as some terrestrial industries constitute environments where electronic systems are anticipated to be exposed to extreme temperatures and wide-range thermal swings. Electronics that are able to withstand and operate efficiently in such harsh environments would simplify, if not eliminate, traditional thermal control elements and their associated structures for proper ambient operation. As a result, overall system mass would be reduced, design would be simplified, and reliability would be improved. Electronic parts that are built utilizing silicon-on-insulator (SOI) technology are known to offer better radiation-tolerance compared to their conventional silicon counterparts, provide faster switching, and consume less power. They also exhibit reduced leakage current and, thus, they are often tailored for high temperature operation. These attributes make SOI-based devices suitable for use in harsh environments where extreme temperatures and wide thermal swings are anticipated. A new operational amplifier, based on silicon-on-insulator technology and geared for high temperature well-logging applications, was recently introduced by Honeywell Corporation. This HTOP-01 dual precision operational amplifier is a low power device, operates on a single supply, and has an internal oscillator and an external clocking option [1]. It is rated for operation from -55 C to +225 C with a maximum output current capability of 50 mA. The amplifier chip is designed as a 14-pin, hermetically-sealed device in a ceramic package. Table I shows some of the device manufacturer s specifications.

  10. Electric-field-induced Skyrmion distortion and giant lattice rotation in the magnetoelectric insulator Cu2OSeO3.

    Science.gov (United States)

    White, J S; Prša, K; Huang, P; Omrani, A A; Zivković, I; Bartkowiak, M; Berger, H; Magrez, A; Gavilano, J L; Nagy, G; Zang, J; Rønnow, H M

    2014-09-05

    Uniquely in Cu2OSeO3, the Skyrmions, which are topologically protected magnetic spin vortexlike objects, display a magnetoelectric coupling and can be manipulated by externally applied electric (E) fields. Here, we explore the E-field coupling to the magnetoelectric Skyrmion lattice phase, and study the response using neutron scattering. Giant E-field induced rotations of the Skyrmion lattice are achieved that span a range of ∼25°. Supporting calculations show that an E-field-induced Skyrmion distortion lies behind the lattice rotation. Overall, we present a new approach to Skyrmion control that makes no use of spin-transfer torques due to currents of either electrons or magnons.

  11. Statistical and electrical properties of the conduction electrons of a metal nanosphere in the region of metal-insulator transition.

    Science.gov (United States)

    Datsyuk, Vitaly V; Ivanytska, Iryna V

    2014-01-01

    Statistical and electrical properties of the conduction electrons of a silver or gold sphere with a radius from 1 to 2 nm are shown to differ drastically from the properties of electrons in a bulk metal sample. If the radius of a noble metal sphere decreases from 10 to 1 nm, its conductivity oscillates around the bulk metal value with increasing amplitude and drops at the 'magic' numbers of electrons. These numbers are equal to 186, 198, 254, 338, 440, 556, 676, 832, 912, 1,284, 1,502, and 1,760, in agreement with various experimental data. We show that the conductivity and capacitance of a metal nanosphere can be changed by several orders of magnitude by adding or removing just a few electrons.

  12. Impact of alternate fuels on industrial refractories and refractory insulation applications. An Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Wei, G.C.; Tennery, V.J.

    1976-09-01

    The effects of use of alternate fuels such as distillate oils, residual oils, coal, producer gas, and electricity on refractory insulation are evaluated. Sections are included on alternate fuels for 1976 to 1980, assessment by industry of fuel conversion impact on industrial refractories in the period 1976 to 1980, interactions of alternate fuel combustion products with refractories and refractory insulation, and analysis of degradation mechanisms in refractories and refractory materials. (JRD)

  13. Effects Of Radiation On Insulators

    Science.gov (United States)

    Bouquet, Frank L.

    1988-01-01

    Report presents data on responses of electrically insulating thermosetting and thermoplastic polymers to radiation. Lowest-threshold-dose (LTD) levels and 25-percent-change levels presented for such properties as tensile strength and electrical resistivity. Data on radiation-induced outgassing also given.

  14. Automotive Insulation

    Science.gov (United States)

    1997-01-01

    Under a Space Act Agreement between Boeing North America and BSR Products, Space Shuttle Thermal Protection System (TPS) materials are now used to insulate race cars. BSR has created special TPS blanket insulation kits for use on autos that take part in NASCAR events, and other race cars through its nationwide catalog distribution system. Temperatures inside a race car's cockpit can soar to a sweltering 140 to 160 degrees, with the extreme heat coming through the engine firewall, transmission tunnel, and floor. It is common for NASCAR drivers to endure blisters and burns due to the excessive heat. Tests on a car insulated with the TPS material showed a temperature drop of some 50 degrees in the driver's cockpit. BSR-TPS Products, Inc. now manufactures insulation kits for distribution to race car teams around the world.

  15. Electric and hybrid electric vehicles. Report of the International Evaluation Committee. June 96

    Energy Technology Data Exchange (ETDEWEB)

    Kahlen, H. [Univ. Kaiserslautern (Germany); Maggetto, G. [Vrije Univ., Brussel (Belgium); Scrosati, B. [Univ. di Roma (Italy); Srinivasan, S. [Texas A and M Univ., College Station (United States)

    1996-11-01

    As requested by NUTEK our task was to evaluate the results and progress achieved in the electric and hybrid electric vehicles programme. This is a multidisciplinary research programme involving 12 projects at four universities and is planned to be extended over two three-year periods, i.e. 1993-1996 and 1997-1999 at a level of 8 MSKR (about USD 1,2M) per year. The programme has been launched to stimulate the development of electric vehicle technology in Sweden and is supporting projects to optimize the material processes, improve battery and engine components and promote of their production by the Swedish industry. In addition, the programme is directed to: 1. improve the knowledge and experience in the field at the academic level; 2. to support long time research on the subject and, 3. promote collaboration nationally and internationally. Our first comment is that the latter aspect appears to be satisfactorily accomplished. Most of the groups we have visited demonstrate an acquired experience in the field and presented their results with competence and enthusiasm. In many cases, we found valid interactions on ongoing projects in Swedish universities and established collaborations with high rank international groups. The programme has provided the material and the motivation for high-quality thesis work and, consequently, the formation of a class of well prepared and professionally competent students. Since electric vehicle technology is fast developing and is expected to have important fall-outs not only in the car industry but also in battery and electric engine manufacturing, the training of competent scientists and engineers in the field is of paramount relevance for Sweden where these types of industries are active and spread out. Therefore, we believe that as far as educational promotion is concerned, the funds distribution was worthwhile in all the projects which we evaluated

  16. Achieving safe hands-on defibrillation using electrical safety gloves--a clinical evaluation.

    Science.gov (United States)

    Deakin, Charles D; Thomsen, Jakob E; Løfgren, Bo; Petley, Graham W

    2015-05-01

    Safe hands-on defibrillation (HOD) will allow uninterrupted chest compression during defibrillation and may improve resuscitation success. We tested the ability of electrical insulating gloves to protect the rescuer during HOD using a 'worst case' electrical scenario. Leakage current flowing from the patient to the 'rescuer' during antero-lateral defibrillation of patients undergoing elective cardioversion was measured. The 'rescuer' maintained firm (20 kgf) contact with the patient during defibrillation, wearing Class 1 electrical insulating gloves while simulating an inadvertent contact with the patient, through an additional wired contact between 'rescuer' and patient. Data from 61 shocks from 43 different patients were recorded. The median leakage current from all defibrillations was 20.0 μA, (range: 2.0-38.5). In total, 18 of the shocks were delivered at 360 J and had a median leakage current of 27.0 μA (range: 14.3-38.5). When using Class 1 electrical insulating gloves for hands-on defibrillation, rescuer leakage current is significantly below the 1 mA safe threshold, allowing safe hands-on defibrillation if the rescuer makes only one other point of contact with the patient. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Seismic Evaluation of Structural Insulated Panels in Comparison with Wood-Frame Panels

    Directory of Open Access Journals (Sweden)

    Stefanie Terentiuk

    2014-07-01

    Full Text Available Structural Insulated Panel (SIP wall systems have been used in residential and light commercial buildings for the past sixty years. Lack of sufficient published research on racking load performance and limited understanding of the influence of fastener types on seismic response has been a deterrent in widespread use of the wall system in seismically active areas. This paper presents the results of a study involving a total of twenty one 2.4 m × 2.4 m shear walls tested under monotonic and cyclic loading. Four different 114 mm thick SIP panel configurations and one traditional wood frame wall were tested under monotonic loading according to ASTM E 564-06; and thirteen 114 mm thick SIP panels and three wood frame walls were tested under the CUREE loading protocol according to ASTM E 2126-11. Parameters such as fastener type; spline design; hold-down anchor location; and sheathing bearing were adjusted throughout the testing in order to determine their effects on the SIP’s performance. Performance parameters such as peak load and displacement; energy dissipation; allowable drift load capacity and seismic compatibility were determined for all of the specimens. Such parameters were then used to demonstrate the SIP walls’ compatibility with the wood frame walls and to determine the efficiency of the different SIP wall configuration and spline systems employed.

  18. Evaluating signal-to-noise ratios, loudness, and related measures as indicators of airborne sound insulation.

    Science.gov (United States)

    Park, H K; Bradley, J S

    2009-09-01

    Subjective ratings of the audibility, annoyance, and loudness of music and speech sounds transmitted through 20 different simulated walls were used to identify better single number ratings of airborne sound insulation. The first part of this research considered standard measures such as the sound transmission class the weighted sound reduction index (R(w)) and variations of these measures [H. K. Park and J. S. Bradley, J. Acoust. Soc. Am. 126, 208-219 (2009)]. This paper considers a number of other measures including signal-to-noise ratios related to the intelligibility of speech and measures related to the loudness of sounds. An exploration of the importance of the included frequencies showed that the optimum ranges of included frequencies were different for speech and music sounds. Measures related to speech intelligibility were useful indicators of responses to speech sounds but were not as successful for music sounds. A-weighted level differences, signal-to-noise ratios and an A-weighted sound transmission loss measure were good predictors of responses when the included frequencies were optimized for each type of sound. The addition of new spectrum adaptation terms to R(w) values were found to be the most practical approach for achieving more accurate predictions of subjective ratings of transmitted speech and music sounds.

  19. Dirac-electron-mediated magnetic proximity effect in topological insulator/magnetic insulator heterostructures

    Science.gov (United States)

    Li, Mingda; Song, Qichen; Zhao, Weiwei; Garlow, Joseph A.; Liu, Te-Huan; Wu, Lijun; Zhu, Yimei; Moodera, Jagadeesh S.; Chan, Moses H. W.; Chen, Gang; Chang, Cui-Zu

    2017-11-01

    The possible realization of dissipationless chiral edge current in a topological insulator/magnetic insulator heterostructure is based on the condition that the magnetic proximity exchange coupling at the interface is dominated by the Dirac surface states of the topological insulator. Here we report a polarized neutron reflectometry observation of Dirac-electron-mediated magnetic proximity effect in a bulk-insulating topological insulator (B i0.2S b0.8)2 T e3 /magnetic insulator EuS heterostructure. We are able to maximize the proximity-induced magnetism by applying an electrical back gate to tune the Fermi level of topological insulator to be close to the Dirac point. A phenomenological model based on diamagnetic screening is developed to explain the suppressed proximity-induced magnetism at high carrier density. Our work paves the way to utilize the magnetic proximity effect at the topological insulator/magnetic insulator heterointerface for low-power spintronic applications.

  20. Evaluation of 2004 Toyota Prius Hybrid Electric Drive System

    Energy Technology Data Exchange (ETDEWEB)

    Staunton, R. H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Engineering Science and Technology Division; Ayers, C. W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Engineering Science and Technology Division; Marlino, L. D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Engineering Science and Technology Division; Chiasson, J. N. [Univ. of Tennessee, Knoxville, TN (United States); Burress, B. A. [Oak Ridge Inst. for Science and Education (ORISE), Oak Ridge, TN (United States)

    2006-05-01

    The 2004 Toyota Prius is a hybrid automobile equipped with a gasoline engine and a battery- and generator-powered electric motor. Both of these motive-power sources are capable of providing mechanical-drive power for the vehicle. The engine can deliver a peak-power output of 57 kilowatts (kW) at 5000 revolutions per minute (rpm) while the motor can deliver a peak-power output of 50 kW over the speed range of 1200–1540 rpm. Together, this engine-motor combination has a specified peak-power output of 82 kW at a vehicle speed of 85 kilometers per hour (km/h). In operation, the 2004 Prius exhibits superior fuel economy compared to conventionally powered automobiles. To acquire knowledge and thereby improve understanding of the propulsion technology used in the 2004 Prius, a full range of design characterization studies were conducted to evaluate the electrical and mechanical characteristics of the 2004 Prius and its hybrid electric drive system. These characterization studies included (1) a design review, (2) a packaging and fabrication assessment, (3) bench-top electrical tests, (4) back-electromotive force (emf) and locked rotor tests, (5) loss tests, (6) thermal tests at elevated temperatures, and most recently (7) full-design-range performance testing in a controlled laboratory environment. This final test effectively mapped the electrical and thermal results for motor/inverter operation over the full range of speeds and shaft loads that these assemblies are designed for in the Prius vehicle operations. This testing was undertaken by the Oak Ridge National Laboratory (ORNL) as part of the U.S. Department of Energy (DOE) – Energy Efficiency and Renewable Energy (EERE) FreedomCAR and Vehicle Technologies (FCVT) program through its vehicle systems technologies subprogram. The thermal tests at elevated temperatures were conducted late in 2004, and this report does not discuss this testing in detail. The thermal tests explored the derating of the Prius motor design

  1. EVA Metro Sedan electric-propulsion system: test and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Reimers, E.

    1979-09-01

    The procedure and results of the performance evaluation of the EVA Metro Sedan (car No. 1) variable speed dc chopper motor drive and its three speed automatic transmission are presented. The propulsion system for a battery powered vehicle manufactured by Electric Vehicle Associates, Valley View, Ohio, was removed from the vehicle, mounted on the programmable electric dynamometer test facility and evaluated with the aid of a hp 3052A Data Acquisition System. Performance data for the automatic transmission, the solid state dc motor speed controller, and the dc motor in the continuous and pulsating dc power mode, as derived on the dynamometer test facility, as well as the entire propulsion system are given. This concept and the system's components were evaluated in terms of commercial applicability, maintainability, and energy utility to establish a design base for the further development of this system or similar propulsion drives. The propulsion system of the EVA Metro Sedan is powered by sixteen 6-volt traction batteries, Type EV 106 (Exide Battery Mfg. Co.). A thyristor controlled cable form Pulsomatic Mark 10 controller, actuated by a foot throttle, controls the voltage applied to a dc series field motor, rated at 10 hp at 3800 rpm (Baldor Electric Co.). Gear speed reduction to the wheel is accomplished by the original equipment three speed automatic transmission with torque converter (Renault 12 Sedan). The brake consists of a power-assisted, hydraulic braking system with front wheel disk and rear drum. An ability to recuperate electric energy with subsequent storage in the battery power supply is not provided.

  2. Development of insulating coatings for liquid metal blankets

    Energy Technology Data Exchange (ETDEWEB)

    Malang, S.; Borgstedt, H.U. [Kernforschungszentrum Karlsruhe GmbH (Germany); Farnum, E.H. [Los Alamos National Lab., NM (United States); Natesan, K. [Argonne National Lab., IL (United States); Vitkovski, I.V. [Efremov Inst., St. Petersburg (Russian Federation). MHD-Machines Lab.

    1994-07-01

    It is shown that self-cooled liquid metal blankets are feasible only with electrically insulating coatings at the duct walls. The requirements on the insulation properties are estimated by simple analytical models. Candidate insulator materials are selected based on insulating properties and thermodynamic consideration. Different fabrication technologies for insulating coatings are described. The status of the knowledge on the most crucial feasibility issue, the degradation of the resisivity under irradiation, is reviewed.

  3. Performance evaluation of advanced battery technologies for electric vehicle applications

    Science.gov (United States)

    Deluca, W. H.; Tummillo, A. F.; Kulaga, J. E.; Webster, C. E.; Gillie, K. R.; Hogrefe, R. L.

    1990-01-01

    At the Argonne Analysis and Diagnostic Laboratory, advanced battery technology evaluations are performed under simulated electric vehicle operating conditions. During 1989 and the first quarter of 1990, single cell and multicell modules from seven developers were examined for the Department of Energy and Electric Power Research Institute. The results provide battery users, developers, and program managers with an interim measure of the progress being made in battery R&D programs, a comparison of battery technologies, and a source of basic data for modeling and continuing R&D. This paper summarizes the performance and life characterizations of two single cells and seven 3- to 960-cell modules that encompass six technologies (Na/S, Ni/Fe, Ni/Cd, Ni-metal hydride, lead-acid, and Zn/Br).

  4. Effect of annealing temperature on the electrical properties of Au/Ta{sub 2}O{sub 5}/n-GaN metal-insulator-semiconductor (MIS) structure

    Energy Technology Data Exchange (ETDEWEB)

    Prasanna Lakshmi, B.; Rajagopal Reddy, V.; Janardhanam, V. [Sri Venkateswara University, Department of Physics, Tirupati (India); Siva Pratap Reddy, M.; Lee, Jung-Hee [Kyungpook National University, School of Electrical Engineering and Computer Science, Daegu (Korea, Republic of)

    2013-11-15

    We report on the effect of an annealing temperature on the electrical properties of Au/Ta{sub 2}O{sub 5}/n-GaN metal-insulator-semiconductor (MIS) structure by current-voltage (I-V) and capacitance-voltage (C-V) measurements. The measured Schottky barrier height ({Phi} {sub bo}) and ideality factor n values of the as-deposited Au/Ta{sub 2}O{sub 5}/n-GaN MIS structure are 0.93 eV (I-V) and 1.19. The barrier height (BH) increases to 1.03 eV and ideality factor decreases to 1.13 upon annealing at 500 {sup circle} C for 1 min under nitrogen ambient. When the contact is annealed at 600 {sup circle} C, the barrier height decreases and the ideality factor increases to 0.99 eV and 1.15. The barrier heights obtained from the C-V measurements are higher than those obtained from I-V measurements, and this indicates the existence of spatial inhomogeneity at the interface. Cheung's functions are also used to calculate the barrier height ({Phi} {sub bo}), ideality factor (n), and series resistance (R{sub s}) of the Au/Ta{sub 2}O{sub 5}/n-GaN MIS structure. Investigations reveal that the Schottky emission is the dominant mechanism and the Poole-Frenkel emission occurs only in the high voltage region. The energy distribution of interface states is determined from the forward bias I-V characteristics by taking into account the bias dependence of the effective barrier height. It is observed that the density value of interface states for the annealed samples with interfacial layer is lower than that of the density value of interface states of the as-deposited sample. (orig.)

  5. Design and Simulation of an Anode Stalk Support Insulator

    CERN Document Server

    Wang, Lisa; Westenskow, Glen

    2005-01-01

    An anode stalk support insulator in a magnetically insulated transmission line was designed and modeled. One of the important design criteria is that within space constraints, the electric field along the insulator surface has to be minimized in order to prevent a surface flashover. In order to further reduce the field on the insulator surface, metal rings between insulator layers were also specially shaped. To facilitate the design process, electric field simulations were performed to determine the maximum field stress on the insulator surfaces and the transmission line chamber.

  6. Are Kondo insulators simply insulators?

    Energy Technology Data Exchange (ETDEWEB)

    Aeppli, G.; DiTusa, J.F. [AT& T Bell Laboratories, Murray Hill, NJ (United States); Fisk, Z. [Los Alamos National Laboratory, NM (United States)

    1994-12-31

    Since the discovery of the anomalous normal state properties of the high-T{sub c} oxides, there has been a lively debate concerning the applicability of conventional Fermi liquid theory to strongly interacting metals. A question arising naturally in this context is whether strongly interacting insulators exhibit properties at odds with ordinary band theory. Of course, Mott insulators, which in the absence of strong Coulomb interactions would be metals, represent the most dramatic breakdown of band theory. However, among strongly interacting insulators which one believes are band insulators, there have until recently been no indications that many-body effects yield observable consequences beyond those which band parameter renormalization might account for. The large number of recent theoretical papers on this renormalization for f-band materials, as well as the long struggle to achieve quantitative understanding of the band gap in as basic a semiconductor as Si, attest to the importance and difficulty of calculating renormalized band parameters for insulators. Also, the experience with Si clearly shows that the renormalization can depend on the quantity being measured. In a recent review, the authors placed the newly discovered Ce-based Kondo insulators, as well as older anomalous semiconductors such as SmB{sub 6} and FeSi, in the context of renormalized band theory. The conclusion was that in large measure, this theory represents an adequate starting point for understanding strongly correlated insulators. The goal here is not to repeat what was said before, but to focus on those aspects of charge and spin fluctuations which the band picture cannot obviously accomodate.

  7. Topological insulators

    CERN Document Server

    Franz, Marcel

    2013-01-01

    Topological Insulators, volume six in the Contemporary Concepts of Condensed Matter Series, describes the recent revolution in condensed matter physics that occurred in our understanding of crystalline solids. The book chronicles the work done worldwide that led to these discoveries and provides the reader with a comprehensive overview of the field. Starting in 2004, theorists began to explore the effect of topology on the physics of band insulators, a field previously considered well understood. However, the inclusion of topology brings key new elements into this old field. Whereas it was

  8. Scenario Evaluator for Electrical Resistivity survey pre-modeling tool

    Science.gov (United States)

    Terry, Neil; Day-Lewis, Frederick D.; Robinson, Judith L.; Slater, Lee D.; Halford, Keith J.; Binley, Andrew; Lane, John W.; Werkema, Dale

    2017-01-01

    Geophysical tools have much to offer users in environmental, water resource, and geotechnical fields; however, techniques such as electrical resistivity imaging (ERI) are often oversold and/or overinterpreted due to a lack of understanding of the limitations of the techniques, such as the appropriate depth intervals or resolution of the methods. The relationship between ERI data and resistivity is nonlinear; therefore, these limitations depend on site conditions and survey design and are best assessed through forward and inverse modeling exercises prior to field investigations. In this approach, proposed field surveys are first numerically simulated given the expected electrical properties of the site, and the resulting hypothetical data are then analyzed using inverse models. Performing ERI forward/inverse modeling, however, requires substantial expertise and can take many hours to implement. We present a new spreadsheet-based tool, the Scenario Evaluator for Electrical Resistivity (SEER), which features a graphical user interface that allows users to manipulate a resistivity model and instantly view how that model would likely be interpreted by an ERI survey. The SEER tool is intended for use by those who wish to determine the value of including ERI to achieve project goals, and is designed to have broad utility in industry, teaching, and research.

  9. Translucent Insulation

    DEFF Research Database (Denmark)

    Rahbek, Jens Eg

    1998-01-01

    Two new types of translucent materials are presented. One is translucent fiber insulation and the other type is a new type of hony-comb made of Celulose-acetat. Data for the materials and calculations of energy savings when using the materials in building envelopes are presented....

  10. Kondo insulators

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, Z.; Sarrao, J.L. [National High Magnetic Field Lab., Tallahassee, FL (United States); Thompson, J.D. [Los Alamos National Lab., NM (United States)

    1994-10-01

    The Kondo insulating materials present a particularly simple limiting case of the strongly correlated electron lattice problem: one occupied f-state interacting with a single half-filled conduction band. Experiment shows that the solution to this problem has some remarkably simple aspects. Optical conductivity data display the strong coupling nature of this physics.

  11. Evaluation of the Effect of Operating Parameters on Thermal Performance of an Integrated Starter Generator in Hybrid Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Moo-Yeon Lee

    2015-08-01

    Full Text Available The belt-driven-type integrated starter generator motor in a hybrid electric vehicle is vulnerable to thermal problems owing to its high output power and proximity to the engine. These problems may cause demagnetization and insulation breakdown, reducing the performance and durability of the motor. Hence, it is necessary to evaluate the thermal performance and enhance the cooling capacity of the belt-driven type Integrated Starter Generator. In this study, the internal temperature variations of the motor were investigated with respect to the operating parameters, particularly the rotation speed and environment temperature. At a maximum ambient temperature of 105 °C and rotation speed (motor design point of 4500 rpm, the coil of the motor was heated to approximately 189 °C in generating mode. The harsh conditions of the starting mode were analyzed by assuming that the motor operates during the start-up time at a maximum ambient temperature of 105 °C and rotation speed (motor design point of 800 rpm; the coil was heated to approximately 200 °C, which is close to the insulation temperature limit. The model for analyzing the thermal performance of the ISG was verified by comparing its results with those obtained through a generating-mode-based experiment

  12. Simplified topological invariants for interacting insulators

    OpenAIRE

    Zhong Wang; Shou-Cheng Zhang

    2012-01-01

    We propose general topological order parameters for interacting insulators in terms of the Green’s function at zero frequency. They provide a unified description of various interacting topological insulators including the quantum anomalous Hall insulators and the time-reversal-invariant insulators in four, three, and two dimensions. Since only the Green’s function at zero frequency is used, these topological order parameters can be evaluated efficiently by most numerical and analytical algori...

  13. Quality Evaluation of the Modified Diesel-Electric Train (KRDE

    Directory of Open Access Journals (Sweden)

    Taufik Hidayat

    2013-07-01

    Full Text Available Quality of the diesel-electric train (KRDE modified from the electric train (A and B types which were used in three operating regions in the Indonesian Railway Company has been evaluated by analyzing the cause of the KRDE damages in terms of some aspects including: design, components quality, maintenance (method, finance, human resources, environment and way of operation. Based on the evaluation, it was found that the modification of the both types of KRDE provided a very low reliability and availability due to design and technical problems, as well as unoptimal maintenance. In KRDE type A, damage occurs in the cabling system, compressor, radiator fan system, and the braking system. While in type B, damage occurs in the traction motors, static inverter, and radiator fan. It is predicted that their life span can not reach the design life of 25 years, and even they are expected to be grounded. Many improvement is required to lengten their service life including: repair, modification, human resource competence, facilities, spare parts, maintenance and management.

  14. Evaluation of electrical power alternatives for the Pacific Northwest

    Energy Technology Data Exchange (ETDEWEB)

    1977-09-01

    This study evaluates the concept of implementation of large-scale energy conservation to reduce end-use demand for electrical energy as an alternative to the need for continued construction of new power plants to meet projected energy requirements for the Pacific Northwest. In particular, the numerical accuracy, economic feasibility, and institutional impact of a conservation-oriented scenario developed by the Natural Resources Defense Council, Inc., is assessed, relative to the energy forecast prepared by the Pacific Northwest Utilities Conference Commission. The results of this study are presented in four detailed sections following an introductory and summary section: Reconstruction and Numerical Evaluation of Alternative Scenario; Economic Analysis; Institutional Impact; and Impact of New National Energy Policy.

  15. THE ELECTROSTATIC CHARACTERISTICS OF LINEAR INSULATORS FOR CONTACT NETWORKS OF RAILWAYS

    Directory of Open Access Journals (Sweden)

    Ye. D. Kim

    2009-03-01

    Full Text Available On the base of numeric investigations on mathematical models of stationary electric field the basic electric performances of insulating suspensions from porcelain and polymeric insulators for contact nets of alternating and direct current are compared.

  16. THE ELECTROSTATIC CHARACTERISTICS OF LINEAR INSULATORS FOR CONTACT NETWORKS OF RAILWAYS

    OpenAIRE

    Ye. D. Kim; V. H. Sychenko; V. L. Kalmykov

    2009-01-01

    On the base of numeric investigations on mathematical models of stationary electric field the basic electric performances of insulating suspensions from porcelain and polymeric insulators for contact nets of alternating and direct current are compared.

  17. Evaluation of physical parameters of localized states in insulating Y-Ba-Cu-O layers by means of electronic transport measurements

    Energy Technology Data Exchange (ETDEWEB)

    Moran, O., E-mail: omoranc@unalmed.edu.c [Laboratorio de Materiales Ceramicos y Vitreos, Departamento de Fisica, Universidad Nacional de Colombia, sede Medellin, A.A. 568, Medellin (Colombia)

    2010-02-01

    Electronic transport measurements were carried out on YBa{sub 2}Cu{sub 3}O{sub 7-d}elta/insulator/Au planar junctions in order to determine physical parameters of the localized states in thin insulating Y-Ba-Cu-O layers. In doing so, 12x5 mum{sup 2} YBa{sub 2}Cu{sub 3}O{sub 7-d}elta/insulator/Au junction areas were defined by standard lithographic techniques and Ar ion milling. The analysis of the conductance of the junction at high-temperature or high-bias voltages showed that Mott's variable-range hopping conduction model is appropriated to describe the electrical behavior of the junction in this regime. From the fitting procedure, important physical parameters of the barrier such as the localization length alpha{sup -1} (approx3 A), the average barrier height phi (approx0.5 eV) or the variable range hopping length l{sub in} (approx20 A at approx300 K) were estimated. The experimentally estimated values were physically reasonable and comparable to those reported for other oxide materials.

  18. Evaluation of 2004 Toyota Prius Hybrid Electric Drive System

    Energy Technology Data Exchange (ETDEWEB)

    Staunton, Robert H [ORNL; Ayers, Curtis William [ORNL; Chiasson, J. N. [University of Tennessee, Knoxville (UTK); Burress, Timothy A [ORNL; Marlino, Laura D [ORNL

    2006-05-01

    The 2004 Toyota Prius is a hybrid automobile equipped with a gasoline engine and a battery- and generator-powered electric motor. Both of these motive-power sources are capable of providing mechanical-drive power for the vehicle. The engine can deliver a peak-power output of 57 kilowatts (kW) at 5000 revolutions per minute (rpm) while the motor can deliver a peak-power output of 50 kW over the speed range of 1200-1540 rpm. Together, this engine-motor combination has a specified peak-power output of 82 kW at a vehicle speed of 85 kilometers per hour (km/h). In operation, the 2004 Prius exhibits superior fuel economy compared to conventionally powered automobiles. To acquire knowledge and thereby improve understanding of the propulsion technology used in the 2004 Prius, a full range of design characterization studies were conducted to evaluate the electrical and mechanical characteristics of the 2004 Prius and its hybrid electric drive system. These characterization studies included (1) a design review, (2) a packaging and fabrication assessment, (3) bench-top electrical tests, (4) back-electromotive force (emf) and locked rotor tests, (5) loss tests, (6) thermal tests at elevated temperatures, and most recently (7) full-design-range performance testing in a controlled laboratory environment. This final test effectively mapped the electrical and thermal results for motor/inverter operation over the full range of speeds and shaft loads that these assemblies are designed for in the Prius vehicle operations. This testing was undertaken by the Oak Ridge National Laboratory (ORNL) as part of the U.S. Department of Energy (DOE) - Energy Efficiency and Renewable Energy (EERE) FreedomCAR and Vehicle Technologies (FCVT) program through its vehicle systems technologies subprogram. The thermal tests at elevated temperatures were conducted late in 2004, and this report does not discuss this testing in detail. The thermal tests explored the derating of the Prius motor design if

  19. The Insulation Properties of Oil-Impregnated Insulation Paper Reinforced with Nano-TiO2

    OpenAIRE

    Ruijin Liao; Cheng Lv; Lijun Yang; Yiyi Zhang; Weiqiang Wu; Chao Tang

    2013-01-01

    Oil-impregnated insulation paper has been widely used in transformers because of its low cost and desirable physical and electrical properties. However, research to improve the insulation properties of oil-impregnated insulation paper is rarely found. In this paper, nano-TiO2 was used to stick to the surface of cellulose which was used to make insulation paper. After oil-impregnated insulation paper reinforced by nano-TiO2 was prepared, the tensile strength, breakdown strength, and dielectric...

  20. Improved insulator layer for MIS devices

    Science.gov (United States)

    Miller, W. E.

    1980-01-01

    Insulating layer of supersonic conductor such as LaF sub 3 has been shown able to impart improved electrical properties to photoconductive detectors and promises to improve other metal/insulator/semiconductor (MIS) devices, e.g., MOSFET and integrated circuits.

  1. Evaluation of subsidy for electricity savings in households; Evaluering av tilskuddsordning for elektrisitetssparing i husholdninger

    Energy Technology Data Exchange (ETDEWEB)

    2010-04-15

    Ramboll Management Consulting (Ramboll) has on behalf of Enova SF (Enova) conducted an evaluation of the 'Grant Scheme for electricity savings in households'. The evaluation is conducted in the period January to March 2009, Ramboll is solely responsible for all the analysis, conclusions and recommendations in the report. The evaluation conducted on the basis of a review of the grant assessed on the basis of six evaluation themes. The evaluation will form the basis for further work on the grant by Enova and in their reporting to the Ministry of Petroleum and Energy (OED). (AG)

  2. RESEARCH OF THE INFLUENCE OF VARIOUS FACTORS ON THE ACCURACY OF DETERMINING OF PARAMETERS AND PLACE OF INSULATION DAMAGE IN THE ELECTRIC NETWORKS OF 6 TO 35 KV

    Directory of Open Access Journals (Sweden)

    Naraeva R.R

    2013-12-01

    Full Text Available The present paper is devoted to the research of the method for determining the parameters and plot of insulation damage in the networks of 6 to 35 kV with isolated neutral on the basis of measuring the operating parameters of the network. In the considered three-phase circuit with a symmetric source of EMF and symmetric loading there was a damage of insulation in one of the phases. The calculations are carried out for the transmission line equivalent circuit with a branch line by means of node-potential method. An investigation of the influence of the magnitude of insulation conductivity in the place of damage of different sections of the network upon the accuracy of determining the insulation conductivity is conducted using the data from digital models. The research of this method is performed by advancing hypotheses about the place of damage and by considering the influence of the multiplicity of increasing insulation conductivity of the damaged section and accuracy class of measuring devices.

  3. Dissociative adsorption of environment-friendly insulating medium C3F7CN on Cu(111) and Al(111) surface: A theoretical evaluation

    Science.gov (United States)

    Zhang, Xiaoxing; Li, Yi; Chen, Dachang; Xiao, Song; Tian, Shuangshuang; Tang, Ju; Wang, Dibo

    2018-03-01

    SF6 is extensively used in electrical applications because of its excellent insulation and arc extinguishing performance, but its strong greenhouse effect has negative impact on the atmosphere. The excellent performance of C3F7CN in greenhouse effect, insulation ability, safety, and thermal stability has been demonstrated, indicating that this compound can replace SF6 in electrical applications. However, little information is available on the compatibility of C3F7CN with metals, such as copper and aluminum, in devices. Material compatibility between new gas mixtures and materials used in Gas Insulated Switchgear (GIS) should be investigated to determine the long-term behavior of materials. In this paper, dissociative adsorption of C3F7CN on Cu (1 1 1) and Al (1 1 1) surfaces were analyzed based on density functional theory. Adsorption energy, charge transfer, density of states, and electron density difference of interaction between C3F7CN and two metals were analyzed. It was found that the adsorption energy of C3F7CN adsorbed on Cu (1 1 1) and Al (1 1 1) is both below 0.8 eV. This value indicates that the interaction between them is not very strong. In addition, the dissociation reaction path of gas molecules after adsorption requires certain activation energy. Therefore, C3F7CN and copper or aluminum have certain compatibility and the compatibility of C3F7CN with aluminum is better than that of copper. Related results provide a reference for predicting the aging mechanism of equipment and the selection or modification of major materials for equipment.

  4. Combination of scanning probe microscopy techniques for evaluating the electrical parameters of individual multiwalled carbon nanotubes

    Science.gov (United States)

    Sokolov, D. V.; Davletkildeev, N. A.; Bolotov, V. V.; Lobov, I. A.

    2017-10-01

    Using two techniques of scanning probe microscopy, the electrical properties (work function, Fermi level position, free carriers’ concentration, electrical resistance, conductivity, and carriers’ mobility) of individual multiwalled carbon nanotubes were evaluated.

  5. Evaluation of Electrical Tree Degradation in Cross-Linked Polyethylene Cable Using Weibull Process of Propagation Time

    Directory of Open Access Journals (Sweden)

    Donguk Jang

    2017-11-01

    Full Text Available The main purpose of this paper is to evaluate electrical tree degradation for cross-linked polyethylene (XLPE cable insulation for three difference models. In order to show the distribution characteristics using phase resolved partial discharge (PD, we acquire data by using a PD detecting system. These acquired data presented four 2D distributions such as phase angle-average discharge distribution, pulse magnitude-pulse number distribution, phase angle-pulse number distribution, and phase angle-maximum discharge derived from the distribution of PD. From the analysis of these distributions, each of the tree models are proved to hold its unique characteristics and the results were then applied as basic specific qualities. In order to evaluate the progresses of an electrical tree, we proposed methods using parameters by means of Weibull distribution to the time of tree propagation. We measured the time of tree propagation for 16 specimens of each artificial tree models from initiation stage, middle stage, and final stage respectively, using these breakdown data, we estimated the shape parameter, scale parameter, and mean time to failure. It is possible to analyze the difference in lifetime between the initial stage, the middle stage, and the final stage, and could be used to predict the lifetime of an XLPE cable from these results.

  6. Study of Temperature Distribution Along an Artificially Polluted Insulator String

    Science.gov (United States)

    Subba, Reddy B.; Nagabhushana, G. R.

    2003-04-01

    Insulator becomes wet partially or completely, and the pollution layer on it becomes conductive, when collecting pollutants for an extended period during dew, light rain, mist, fog or snow melting. Heavy rain is a complicated factor that it may wash away the pollution layer without initiating other stages of breakdown or it may bridge the gaps between sheds to promote flashover. The insulator with a conducting pollution layer being energized, can cause a surface leakage current to flow (also temperature-rise). As the surface conductivity is non-uniform, the conducting pollution layer becomes broken by dry bands (at spots of high current density), interrupting the flow of leakage current. Voltage across insulator gets concentrated across dry bands, and causes high electric stress and breakdown (dry band arcing). If the resistance of the insulator surface is sufficiently low, the dry band arcs can be propagated to bridge the terminals causing flashover. The present paper concerns the evaluation of the temperature distribution along the surface of an energized artificially polluted insulator string.

  7. Evaluation of electric field distribution in electromagnetic stimulation of human femoral head.

    Science.gov (United States)

    Su, Yukun; Souffrant, Robert; Kluess, Daniel; Ellenrieder, Martin; Mittelmeier, Wolfram; van Rienen, Ursula; Bader, Rainer

    2014-12-01

    Electromagnetic stimulation is a common therapy used to support bone healing in the case of avascular necrosis of the femoral head. In the present study, we investigated a bipolar induction screw system with an integrated coil. The aim was to analyse the influence of the screw parameters on the electric field distribution in the human femoral head. In addition, three kinds of design parameters (the shape of the screw tip, position of the screw in the femoral head, and size of the screw insulation) were varied. The electric field distribution in the bone was calculated using the finite element software Comsol Multiphysics. Moreover, a validation experiment was set up for an identical bone specimen with an implanted screw. The electric potential of points inside and on the surface of the bone were measured and compared to numerical data. The electric field distribution within the bone was clearly changed by the different implant parameters. Repositioning the screw by a maximum of 10 mm and changing the insulation length by a maximum of 4 mm resulted in electric field volume changes of 16% and 7%, respectively. By comparing the results of numerical simulation with the data of the validation experiment, on average, the electric potential difference of 19% and 24% occurred when the measuring points were at a depth of approximately 5 mm within the femoral bone and directly on the surface of the femoral bone, respectively. The results of the numerical simulations underline that the electro-stimulation treatment of bone in clinical applications can be influenced by the implant parameters. © 2014 Wiley Periodicals, Inc.

  8. Nondestructive Evaluation of Foam Insulation on the Space Shuttle External Tank

    Science.gov (United States)

    Richter, Joel; Walker, James L.

    2006-01-01

    Foam loss on the External Tank (ET) during launch can be caused by a number of factors. Voids are the best understood mechanism of foam loss, although it is known that delaminations, cracks and crushed foam can also lead to liberation of foam. Shortly after the Columbia accident, work began on non-destructive evaluation of foam targeted at finding voids and delaminations. After several months of searching for candidate methods capable of inspecting ET foam, the five most promising techniques were taken through a blind test and narrowed down to two methods to develop and use for inspection of the ET. These methods were backscatter radiography and terahertz imaging. The backscatter radiography system measures a test part by detecting Compton backscattered x-ray energy generated by a collimated beam of x-rays directed at the test subject. This collimated beam is scanned across the subject, recording scatter intensity data one pixel at a time until the area of interest is covered. The resulting data can be used to generate an image similar to a radiograph. Some depth information can be gathered utilizing apertures or collimation on the detectors. The detectors are located around the collimated source, making this a single sided inspection. The void detection limit with the currently utilized system is around 0.5 inches in diameter by 0.2 inches high. The terahertz imaging system inspects a test part by utilizing a transceiver to emit a pulse focused at the aluminum skin of the ET, which reflects it back to the transceiver where it is analyzed. The transceiver is scanned across the area of interest until a measurement has been taken at every location. Amplitude, time delay and frequency content are examined to note any discontinuities which may be the result of a void or other type of defect. The pulse currently utilized is in the millimeter wave regime. The void detection limit with this system is around 0.5 inches in diameter by 0.2 inches high. With increased

  9. Common test methods for insulating and sheathing materials of electrical cables - Part 4 Methods specific to polyethylene and polypropylene compounds. Section Two

    CERN Document Server

    International Electrotechnical Commission. Geneva

    1990-01-01

    Gives the methods for measurement of elongation at break after pre-conditioning, for wrapping test after pre-conditioning, for wraping test after thermal ageing in air, for measurement of mass increase, for long-term stability test and for measurement of copper-catalysed oxidative degradation, which apply to polyolefin insulations.

  10. Sizing of electric power transmission lines insulation in areas of vegetation burns occurrences; Dimensionamento do isolamento de LT`s em regioes de queimadas

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, J.R.; Tan, A.L. [CEPEL, Rio de Janeiro, RJ (Brazil); Junqueira, W.S. [Companhia Energetica de Sao Paulo, SP (Brazil); Silva, R.P [ELETROSUL, Curitiba, PR (Brazil); Assuncao, L.A.R. [Furnas, Rio de Janeiro, RJ (Brazil); Melo, M.O.C. [Companhia Hidro Eletrica do Sao Francisco (CHESF), Recife, PE (Brazil); Monassi, V.

    1987-12-31

    This work presents, for several voltages levels used in Brazil, the insulation requirements in order to prevent the occurrence of failures during vegetation burns. The work is based on field tests. The methodology developed is presented as well as the results 5 refs., 2 figs., 14 tabs.

  11. ITER CENTRAL SOLENOID COIL INSULATION QUALIFICATION

    Energy Technology Data Exchange (ETDEWEB)

    Martovetsky, N N; Mann, T L; Miller, J R; Freudenberg, K D; Reed, R P; Walsh, R P; McColskey, J D; Evans, D

    2009-06-11

    An insulation system for ITER Central Solenoid must have sufficiently high electrical and structural strength. Design efforts to bring stresses in the turn and layer insulation within allowables failed. It turned out to be impossible to eliminate high local tensile stresses in the winding pack. When high local stresses can not be designed out, the qualification procedure requires verification of the acceptable structural and electrical strength by testing. We built two 4 x 4 arrays of the conductor jacket with two options of the CS insulation and subjected the arrays to 1.2 million compressive cycles at 60 MPa and at 76 K. Such conditions simulated stresses in the CS insulation. We performed voltage withstand tests and after end of cycling we measured the breakdown voltages between in the arrays. After that we dissectioned the arrays and studied micro cracks in the insulation. We report details of the specimens preparation, test procedures and test results.

  12. Unconventional Fermi surface in an insulating state

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Neil [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Tan, B. S. [Cambridge Univ., Cambridge (United Kingdom); Hsu, Y. -T. [Cambridge Univ., Cambridge (United Kingdom); Zeng, B. [National High Magnetic Field Lab., Tallahassee, FL (United States); Hatnean, M. Ciomaga [Univ. of Warwick, Coventry (United Kingdom); Zhu, Z. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hartstein, M. [Cambridge Univ., Cambridge (United Kingdom); Kiourlappou, M. [Cambridge Univ., Cambridge (United Kingdom); Srivastava, A. [Cambridge Univ., Cambridge (United Kingdom); Johannes, M. D. [Center for Computational Materials Science, Washington, DC (United States); Murphy, T. P. [National High Magnetic Field Lab., Tallahassee, FL (United States); Park, J. -H. [National High Magnetic Field Lab., Tallahassee, FL (United States); Balicas, L. [National High Magnetic Field Lab., Tallahassee, FL (United States); Lonzarich, G. G. [Cambridge Univ., Cambridge (United Kingdom); Balakrishnan, G. [Univ. of Warwick, Coventry (United Kingdom); Sebastian, Suchitra E. [Cambridge Univ., Cambridge (United Kingdom)

    2015-07-17

    Insulators occur in more than one guise; a recent finding was a class of topological insulators, which host a conducting surface juxtaposed with an insulating bulk. Here, we report the observation of an unusual insulating state with an electrically insulating bulk that simultaneously yields bulk quantum oscillations with characteristics of an unconventional Fermi liquid. We present quantum oscillation measurements of magnetic torque in high-purity single crystals of the Kondo insulator SmB6, which reveal quantum oscillation frequencies characteristic of a large three-dimensional conduction electron Fermi surface similar to the metallic rare earth hexaborides such as PrB6 and LaB6. As a result, the quantum oscillation amplitude strongly increases at low temperatures, appearing strikingly at variance with conventional metallic behavior.

  13. Insulation systems for superconducting transmission cables

    DEFF Research Database (Denmark)

    Tønnesen, Ole

    1996-01-01

    This paper describes shortly the status of superconducting transmission lines and assesses what impact the recently discovered BSCCO superconductors may have on the design of the cables.Two basically different insulation systems are discussed:1) The room temperature dielectric design, where...... the electrical insulation is placed outside both the superconducting tube and the cryostat. The superconducting tube is cooled by liquid nitrogen which is pumped through the hollow part of the tube.2) The cryogenic dielectric design, where the electrical insulation is placed inside the cryostat and thus is kept...

  14. Analysis of electrical properties of insulators (Si{sub 3}N{sub 4}, SiO{sub 2}, AlN, and Al{sub 2}O{sub 3})/0.5 nm Si{sub 3}N{sub 4}/AlGaN/GaN heterostructures

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Narihiko; Hiroki, Masanobu; Watanabe, Noriyuki; Oda, Yasuhiro; Yokoyama, Haruki; Enoki, Takatomo; Kobayashi, Takashi [NTT Photonics Laboratories, NTT Corporation, 3-1 Morinosato Wakamiya, Atsugi, Kanagawa 243-0198 (Japan); Yagi, Takuma [NTT Advanced Technology Corporation, 3-1 Morinosato Wakamiya, Atsugi, Kanagawa 243-198 (Japan); Makimoto, Toshiki [NTT Basic Research Laboratories, NTT Corporation, 3-1 Morinosato Wakamiya, Atsugi, Kanagawa 243-0198 (Japan)

    2007-06-15

    The electrical properties in AlGaN/GaN heterostructures with Si- and Al-based insulators (Si{sub 3}N{sub 4}, SiO{sub 2}, AlN, and Al{sub 2}O{sub 3}) have been examined and analyzed. By insulators deposition, significant increase in the two-dimensional electron gas (2DEG) density (N{sub s}) was observed with the order of N{sub s}(Al{sub 2}O{sub 3})>N{sub s}(AlN){proportional_to}N{sub s}(SiO{sub 2})>N{sub s}(Si{sub 3}N{sub 4})>N{sub 0} (N{sub 0}: N{sub s} without insulators). As the result, the decrease in the sheet resistance (R) was observed; the smallest order of R was R(Al{sub 2}O{sub 3})insulator). The insulators deposition effect has thus been shown to be significant and different among insulators. The increase in N{sub s} was analyzed in terms of the change in the potential profile, and the observed differences in N{sub s} among insulators have been interpreted. The band engineering including insulators is indispensable in understanding and designing AlGaN/GaN HFETs, since insulators are commonly used for the surface passivation as well as for the gate insulators, and the insulators deposition is to alter the essential device parameters such as the source resistance. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  15. Insulator coating for high temperature alloys method for producing insulator coating for high temperature alloys

    Science.gov (United States)

    Park, Jong Hee

    1998-01-01

    A method for fabricating an electrically insulating coating on a surface is disclosed comprising coating the surface with a metal, and reacting the metal coated surface with a nonmetal so as to create a film on the metal-coated surface. Alternatively, the invention provides for a method for producing a noncorrosive, electrically insulating coating on a surface saturated with a nonmetal comprising supplying a molten fluid, dissolving a metal in the molten fluid to create a mixture, and contacting the mixture with the saturated surface. Lastly, the invention provides an electrically insulative coating comprising an underlying structural substrate coated with an oxide or nitride compound

  16. COMPLEX EVALUATION OF ELECTRIC RAIL TRANSPORT IMPLEMENTATION IN VILNIUS CITY

    Directory of Open Access Journals (Sweden)

    Gintautas BUREIKA

    2016-03-01

    Full Text Available The article analyses the current problems of Vilnius city public transportation. The possible solutions (options and the technical means to improve the attractiveness of public transportation and accessibility are considered. Two main alternatives of means of electric transport (underground and tram have been singled out for Vilnius city. The suitability of these rail transport means have been substantiated. The nature and density of the work and residence places (areas of Vilnius city residents have been analysed. The scheme of tram and underground lines projected in Vilnius city are evaluated, which have been composed according to the current and forecasted flows of passengers, the nature of their changes and critical points. The technical economic indicators of the tram routes and underground lines in Vilnius city are analysed: average driving speed, average distance between the stations, the duration of the trip, the capacity of a single means of transport, the costs of line support and the size of investment. The accident rate of urban rail transportation is estimated. Comparative criteria of tram and underground lines are selected. The effectiveness of both rail means of transport in Vilnius city are compared according to three multi-criteria evaluation methods: the sum of ratings, simple additive weighting and geometrical means. The final conclusions and recommendations are provided.

  17. Corrugated outer sheath gas-insulated transmission line

    Science.gov (United States)

    Kemeny, George A.; Cookson, Alan H.

    1981-01-01

    A gas-insulated transmission line includes two transmission line sections each of which are formed of a corrugated outer housing enclosing an inner high-voltage conductor disposed therein, with insulating support means supporting the inner conductor within the outer housing and an insulating gas providing electrical insulation therebetween. The outer housings in each section have smooth end sections at the longitudinal ends thereof which are joined together by joining means which provide for a sealing fixed joint.

  18. Selection of the external insulation distance for electric equipment as function of the environmental pollution level; Seleccion de la distancia de aislamiento externo de equipo electrico en funcion del nivel de contaminacion ambiental

    Energy Technology Data Exchange (ETDEWEB)

    Villa Velazquez Santillanes, Francisco [Gerencia de Proyectos Geotermoelectricos de la Comision Federal de Electricidad, Morelia (Mexico)

    1996-09-01

    Geographic, environmental and meteorological conditions, are considered as decisive factors in the basic engineering and design of electric substations. These conditions are considered through the use of environmental and meteorological parameters, such as: pollution type, creepage distance, pollution level, maximum wind rate, maximum temperature, seismic coefficient and maximum pluvial precipitation. In some cases, the pollution level determines the external insulation distance. The pollution level factor is quantified as the equivalent salt accumulation in milligrams per square centimeter of the insulation surface (DESD), occurring during certain time, that produces an electric effect similar to that of the real pollutant. [Espanol] Los aspectos geograficos, ambientales y meteorologicos son factores que se deben considerar en la ingenieria basica de las subestaciones electricas. En el diseno de estas se utilizan parametros asociados con las condiciones ambientales y meteorologicas, como son: tipo de contaminacion, distancia de fuga, nivel de contaminacion, velocidad maxima del viento, temperatura ambiental maxima, temperatura ambiental minima, coeficiente sismico y maxima precipitacion pluvial. La contaminacion se produce por la depositacion de polvo y otras sustencias quimicas sobre los aisladores. Para cuantificar la contaminacion se recurre al concepto de Densidad Equivalente de Sal Depositada (DESD), que consiste en medir la contaminacion en funcion de la cantidad de sal (NaC1) depositada en cierto tiempo, por centimetro cuadrado del aislador, tal que su comportamiento electrico es equivalente al de los contaminantes reales.

  19. Magnetic and electrical response of Co-doped La{sub 0.7}Ca{sub 0.3}MnO{sub 3} manganites/insulator system

    Energy Technology Data Exchange (ETDEWEB)

    Debnath, J.C., E-mail: Jyotish.debnath@deakin.edu.au [Institute for Frontier Materials, Deakin University, Geelong, VIC 3216 (Australia); Wang, Jianli, E-mail: jcd341@uowmail.edu.au [Institute for Superconductivity and Electronic Materials, University of Wollongong, Wollongong, NSW 2522 (Australia)

    2017-01-01

    We present a systematic study of the structural, magnetic and electrical properties of La{sub 0.7}Ca{sub 0.3}MnO{sub 3} (LCMO) and La{sub 0.7}Ca{sub 0.3}Mn{sub 0.95}Co{sub 0.05}O{sub 3} (LCMCO0 perovskite manganites. Most of the work is devoted to the electrical properties with a thorough discussion about different models for both the metallic and insulator states. With a view to understand the conduction mechanism in these materials, the resistivity of both materials was measured over a temperature range 5–300 K and in a magnetic field up to 1 T and the data were analysed by using several theoretical models. It has been observed that the metallic part of the temperature dependent resistivity (ρ) curve fits well with ρ=ρ{sub 0} +ρ{sub 2,5}Τ{sup 2,5}, indicating the electron–magnon scattering processes in the conduction of these materials. On the other hand, in the high temperature paramagnetic insulating regime, the adiabatic small polaron and VRH models fit well, thereby indicating that polaron hopping might be responsible for the conduction mechanism.

  20. Reliability Evaluation for Optimizing Electricity Supply in a Developing Country

    Directory of Open Access Journals (Sweden)

    Mark Ndubuka NWOHU

    2007-09-01

    Full Text Available The reliability standards for electricity supply in a developing country, like Nigeria, have to be determined on past engineering principles and practice. Because of the high demand of electrical power due to rapid development, industrialization and rural electrification; the economic, social and political climate in which the electric power supply industry now operates should be critically viewed to ensure that the production of electrical power should be augmented and remain uninterrupted. This paper presents an economic framework that can be used to optimize electric power system reliability. Finally the cost models are investigated to take into account the economic analysis of system reliability, which can be periodically updated to improve overall reliability of electric power system.

  1. Fiber glass plastic insulation of power transmission lines. Stekloplastikovaya izolyatsiya liniy elektroperedachi

    Energy Technology Data Exchange (ETDEWEB)

    Aleksandrov, G.N.; Ivanov, V.L.

    1983-01-01

    Results are described of comprehensive studies of electrophysical characteristics of polymer electrical insulation of external design under the main operating effects. The current state of the problem of creation, use and selection of polymer electrical insulation are presented. Fundamentals are presented of the technique of selecting the polymer electrical insulation taking into consideration the specific nature of the fiber glass plastic structure. A technique is developed for calculation and selection of screen fittings for fiber glass plastic electrical insulation designs for apparatus and overhead lines. Reference data are presented which can be used in calculating the fiber glass plastic electrical insulation.

  2. Evaluation of Two CEDA Weatherization Pilot Implementations of an Exterior Insulation and Over-Clad Retrofit Strategy for Residential Masonry Buildings in Chicago

    Energy Technology Data Exchange (ETDEWEB)

    Neuhauser, K.

    2013-08-01

    This project examines the implementation of an exterior insulation and over-clad strategy for brick masonry buildings in Chicago. The strategy was implemented at a free-standing two story two-family dwelling and a larger free-standing multifamily building. The test homes selected for this research represent predominant housing types for the Chicago area. High heating energy use typical in these buildings threaten housing affordability. Uninsulated mass masonry wall assemblies also have a strongly detrimental impact on comfort. Significant changes to the performance of masonry wall assemblies is generally beyond the reach of typical weatherization (Wx) program resources. The Community and Economic Development Association of Cook County, Inc. (CEDA) has secured a Sustainable Energy Resources for Consumers (SERC) innovation grant sponsored by the United States Department of Energy (DOE). This grant provides CEDA the opportunity to pursue a pilot implementation of innovative approaches to retrofit in masonry wall enclosures. The exterior insulation and over-clad strategy implemented through this project was designed to allow implementation by contractors active in CEDA weatherization programs and using materials and methods familiar to these contractors. The retrofit measures are evaluated in terms of feasibility, cost and performance. Through observations of the strategies implemented, the research described in this report identifies measures critical to performance as well as conditions for wider adoption. The research also identifies common factors that must be considered in determining whether the exterior insulation and over-clad strategy is appropriate for the building.

  3. Sparsity reconstruction in electrical impedance tomography: An experimental evaluation

    KAUST Repository

    Gehre, Matthias

    2012-02-01

    We investigate the potential of sparsity constraints in the electrical impedance tomography (EIT) inverse problem of inferring the distributed conductivity based on boundary potential measurements. In sparsity reconstruction, inhomogeneities of the conductivity are a priori assumed to be sparse with respect to a certain basis. This prior information is incorporated into a Tikhonov-type functional by including a sparsity-promoting ℓ1-penalty term. The functional is minimized with an iterative soft shrinkage-type algorithm. In this paper, the feasibility of the sparsity reconstruction approach is evaluated by experimental data from water tank measurements. The reconstructions are computed both with sparsity constraints and with a more conventional smoothness regularization approach. The results verify that the adoption of ℓ1-type constraints can enhance the quality of EIT reconstructions: in most of the test cases the reconstructions with sparsity constraints are both qualitatively and quantitatively more feasible than that with the smoothness constraint. © 2011 Elsevier B.V. All rights reserved.

  4. Evaluation of Glare at the Ivanpah Solar Electric Generating System

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Clifford K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sims, Cianan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Christian, Joshua Mark [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-07-01

    The Ivanpah Solar Electric Generating System (ISEGS), located on I - 15 about 40 miles (60 km) south of Las Vegas, NV, consists of three power towers 459 ft (140 m) tall and over 170,000 reflective heliostats with a rated capacity of 390 MW. Reports of glare from the plant have been submitted by pilots and air traffic controllers and recorded by the Aviation Safety Reporting System and the California Energy Commission since 2013. Aerial and ground - based surveys of the glare were conducted in April, 2014, to identify the cause and to quantify the irradiance and potential ocular impact s of the glare . Results showed that the intense glare viewed from the airspace above ISEGS was caused by he liostats in standby mode that were aimed to the side of the receiver. Evaluation of the glare showed that the retinal irradiance and subtended source angle of the glare from the heliostats in standby were sufficient to cause significant ocular impact (pot ential for after - image) up to a distance of %7E6 miles (10 km), but the values were below the threshold for permanent eye damage . Glare from the receivers had a low potential for after - image at all ground - based monitoring locations outside of the site bound aries. A Letter to Airmen has been issued by the Federal Aviation Administration to notify pilots of the potential glare hazards. Additional measures to mitigate the potential impacts of glare from ISGES are also presented and discussed. This page intentionally left blank

  5. Application of Three Electrical Resistivity Arrays to Evaluate ...

    African Journals Online (AJOL)

    ADOWIE PERE

    https://dx.doi.org/10.4314/jasem.v21i6.36. Keywords: Electrical resistivity array; fractured zones; finite element method; 2-D models; resolution, mean absolute error. Ambiguity in the interpretation of electrical resistivity dataset as well as other geophysical datasets can be reduced by numerical modelling. This allows one to ...

  6. Evaluation of electrical resistivity anisotropy in geological mapping ...

    African Journals Online (AJOL)

    user

    However, the combination of the anisotropy polygons and the iso-resistivity map has reduced the ambiguity inherent in using a single geophysical parameter. Key words: Electrical resistivity anisotropy, radial vertical electrical sounding, anisotropy polygons. INTRODUCTION. The geological mapping in the Precambrian, ...

  7. (VLF-EM) and electrical resistivity survey for evaluation of ...

    African Journals Online (AJOL)

    ENSEMBLES

    2016-05-26

    May 26, 2016 ... complex. Key words: Weathered layer, geological fissures, aquifer, electrical resistivity, geoelectric section, electromagnetic. ... Electrical Resistivity methods was used in this study to delineating geological deep ... partial curve matching were then used for a quantitative computer iteration using the Resist ...

  8. Electric Power Transmission Lines

    Data.gov (United States)

    Department of Homeland Security — Transmission Lines are the system of structures, wires, insulators and associated hardware that carry electric energy from one point to another in an electric power...

  9. Thermal and Electrical Performance Evaluation of PV/T Collectors in UAE

    OpenAIRE

    Kaya, Mustafa

    2013-01-01

    Photovoltaic Thermal/Hybrid collectors are an emerging technology that combines PV and solar thermal collectors by producing heat and electricity simultaneously. In this paper, thermal and electrical performance of PV/T collectors are analyzed and presented for the climate of RAK, UAE. Thermal performance evaluation is done following the collector output model presented in European standard EN 12975-2 and electrical performance evaluation is done by analyzing the effect of water circulation o...

  10. Evaluation of the application of a thermal insulation system: in-situ comparison of seasonal and daily climatic fluctuations

    Czech Academy of Sciences Publication Activity Database

    Fořt, J.; Beran, Pavel; Konvalinka, P.; Pavlík, Z.; Černý, R.

    2017-01-01

    Roč. 57, č. 3 (2017), s. 159-166 ISSN 1210-2709 R&D Projects: GA ČR(CZ) GBP105/12/G059 Institutional support: RVO:68378297 Keywords : in-situ monitoring * temperature * relative humidity * thermal insulation * energy sustainability * seasonal fluctuations Subject RIV: JN - Civil Engineering OBOR OECD: Construction engineering, Municipal and structural engineering https://ojs.cvut.cz/ojs/index.php/ap/article/view/4087/4171

  11. Eddy Current Testing with Giant Magnetoresistance (GMR) Sensors and a Pipe-Encircling Excitation for Evaluation of Corrosion under Insulation.

    Science.gov (United States)

    Bailey, Joseph; Long, Nicholas; Hunze, Arvid

    2017-09-28

    This work investigates an eddy current-based non-destructive testing (NDT) method to characterize corrosion of pipes under thermal insulation, one of the leading failure mechanisms for insulated pipe infrastructure. Artificial defects were machined into the pipe surface to simulate the effect of corrosion wall loss. We show that by using a giant magnetoresistance (GMR) sensor array and a high current (300 A), single sinusoidal low frequency (5-200 Hz) pipe-encircling excitation scheme it is possible to quantify wall loss defects without removing the insulation or weather shield. An analysis of the magnetic field distribution and induced currents was undertaken using the finite element method (FEM) and analytical calculations. Simple algorithms to remove spurious measured field variations not associated with defects were developed and applied. The influence of an aluminium weather shield with discontinuities and dents was ascertained and found to be small for excitation frequency values below 40 Hz. The signal dependence on the defect dimensions was analysed in detail. The excitation frequency at which the maximum field amplitude change occurred increased linearly with the depth of the defect by about 3 Hz/mm defect depth. The change in magnetic field amplitude due to defects for sensors aligned in the azimuthal and radial directions were measured and found to be linearly dependent on the defect volume between 4400-30,800 mm³ with 1.2 × 10-3-1.6 × 10-3 µT/mm³. The results show that our approach is well suited for measuring wall loss defects similar to the defects from corrosion under insulation.

  12. Prospective long-term evaluation of Optim-insulated (Riata ST Optim and Durata) implantable cardioverter-defibrillator leads.

    Science.gov (United States)

    Cairns, John A; Epstein, Andrew E; Rickard, John; Connolly, Stuart J; Buller, Christopher; Wilkoff, Bruce L; Pogue, Janice; Themeles, Ellison; Healey, Jeff S

    2014-12-01

    St Jude Medical Optim-insulated implantable cardioverter-defibrillator leads were designed to impart lubricity, strength, and abrasion resistance while maintaining flexibility and biostability. No long-term prospective follow-up data have been published. The objective of this study was to determine the rates of all-cause mechanical failure and its subtypes (conductor fracture, insulation abrasion, externalized conductors, and other mechanical failures) in a prospective cohort of Optim-insulated implantable cardioverter-defibrillator leads. St Jude Medical established 3 prospective registries and enrolled 11,016 leads implanted in 10,835 patients beginning in 2006. There was standardized baseline documentation, 6-monthly follow-up, adverse events reports (verified by expert staff using detailed algorithms), and documentation of lead revisions or inactivation, study withdrawal, and death. The Population Health Research Institute (McMaster University) was engaged to review database functions, adjudicate all potential mechanical lead failures, and conduct independent analyses of the data. During a median follow-up of 3.2 years, there were 51 mechanical failures (0.46%), with 99.0% survival free of this outcome by 5 years of follow-up. Freedom from conductor fracture was identified in 99.4% and from all-cause abrasion in 99.8% of the leads, and there were no reports of externalized conductors. There were no significant differences in survival among Durata DF4, Durata DF1, and Riata ST Optim leads. Over a mean follow-up of 3.2 years, Optim-insulated leads have low rates of all-cause mechanical failure and no observed externalized conductors. Independent analyses of these registries are designed to provide reliable long-term follow-up information and are ongoing. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  13. Evaluation of the Electricity Saving Fund in Basel, Switzerland; Evaluation des Stromsparfonds Basel

    Energy Technology Data Exchange (ETDEWEB)

    Iten, R.; Vettori, A.; Schmidt, N. [Infras, Zuerich (Switzerland); Vaterlaus, S.; Wild, J. [Plaut (Schweiz) Consulting AG, Bern (Switzerland)

    2003-09-15

    This comprehensive report for the Swiss Federal Office of Energy (SFOE) presents the results of an evaluation made concerning the Electricity Saving Fund operated in Basel, Switzerland. The aims of the fund, which is based on the imposition of a steering levy on electricity consumption, are presented and discussed. It is noted that the political policies behind this promotional scheme differ greatly from those of other Swiss Cantons. This study examines the direct and indirect effects of the steering levy and the resulting bonus for energy-saving consumers and takes a look at possibilities for transferring the idea to other Swiss Cantons. Questions asked include the degree to which the aims were fulfilled, were negative side-effects noted, is the implementation efficient, can the know-how gained be transferred to other communities and Cantons and which general experience was gained in the application of steering levies. Details on the implementation of the Electricity Saving Bonus are presented and discussed. Results of a survey on the perception of the scheme both in the commercial and private sectors are discussed. Also, the results of evaluations made concerning the degree to which the scheme's aims were fulfilled and their usefulness from the national economics point of view are discussed. Suggestions for improvements are presented. The report is concluded with an a selection of annexes on the topics dealt with in the report

  14. Natural ageing of EPDM composite insulators

    Energy Technology Data Exchange (ETDEWEB)

    Vlastos, A.E.; Sherif, E. (Chalmers Univ. of Technology, High Voltage Engineering, S-412 96 Gothenburg (SW))

    1990-01-01

    Long-rod composite insulators, with weather sheds (sheds) made of ethylene propylene rubbers (EPDM), were exposed for many years to HVAC and HVDC under realistic conditions and natural pollution. The change of their properties with time and their aging was studied. The results show that the insulator shed material undergoes a slow degradation process and loses successively its water repelling properties which initially make the EPDM composite insulators superior to inorganic glass and porcelain insulator. The outdoor degradation of the shed material depends on the electric stress, in the environmental factors (such as pollution, rain, salt-laden fog, and UV-radiation from sun) and on the materials and fillers used in the construction of the composite insulators. A thorough macro- and microscopic study of the EPDM composite insulator sheds illustrates the differences of the surface state of EPDM insulators of different makes in which different basic material compositions and fillers are used. The poor performance of aged EPDM composite insulators compared to inorganic insulators depends on the design and on environmental factors.

  15. High-Performance Slab-on-Grade Foundation Insulation Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Louise F. [NorthernSTAR, St. Paul, MN (United States); Mosiman, Garrett E. [NorthernSTAR, St. Paul, MN (United States)

    2015-09-01

    A more accurate assessment of slab-on-grade foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulation at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated).

  16. Evaluation of solar thermal storage for base load electricity generation

    Directory of Open Access Journals (Sweden)

    Adinberg R.

    2012-10-01

    Full Text Available In order to stabilize solar electric power production during the day and prolong the daily operating cycle for several hours in the nighttime, solar thermal power plants have the options of using either or both solar thermal storage and fossil fuel hybridization. The share of solar energy in the annual electricity production capacity of hybrid solar-fossil power plants without energy storage is only about 20%. As it follows from the computer simulations performed for base load electricity demand, a solar annual capacity as high as 70% can be attained by use of a reasonably large thermal storage capacity of 22 full load operating hours. In this study, the overall power system performance is analyzed with emphasis on energy storage characteristics promoting a high level of sustainability for solar termal electricity production. The basic system parameters, including thermal storage capacity, solar collector size, and annual average daily discharge time, are presented and discussed.

  17. The physical phenomena associated with stator winding insulation condition as detected by the ramped direct high-voltage method

    Science.gov (United States)

    Rux, Lorelynn Mary

    Deregulation of the electric utility industry has increased the need to monitor the state of powerplant equipment, such as critical generators and motors, to improve availability and reduce life cycle costs via condition-based maintenance. To achieve these goals, nondestructive condition assessment and diagnostic tests are necessary to evaluate the quality and condition of a machine's stator winding insulation system. Periodic tests are generally conducted to monitor insulation aging, diagnose problems, or provide some assurance that the winding has a minimum level of electrical strength. The basic principles of insulation testing are presented herein, and the physical mechanisms that affect the current versus voltage response are described. A stator winding insulation model was developed based on this theoretical foundation for use in understanding and analyzing the macroscopic behavior of complex insulation phenomena. A comprehensive, controlled laboratory experiment was conducted on a set of stator coils that were deliberately manufactured with and without insulation defects. Specific defects were chosen to represent the types of insulation problems typically encountered during manufacture or as a result of in-service aging, and included lack of resin cure, loosely-applied insulating tapes, internal conductive contamination, reduced density of the groundwall insulation, and thermal cycling damage. Results are presented from a series of electrical tests conducted on the coil specimens to compare the effectiveness of various test methods in detecting the different insulation problems. The tests included insulation resistance, polarization index, ramped direct voltage, dissipation factor, dielectric spectroscopy, partial discharge, and recovery voltage measurements. Dielectric principles and testing experience obtained during this investigation were applied to a collection of test results obtained by the author from in-service machines during the past ten years

  18. Evaluating and Improving Cybersecurity Capabilities of the Electricity Critical Infrastructure

    Science.gov (United States)

    2015-05-01

    challenges • Largest technical program at SEI • Focused on internet security, digital investigation, secure systems, insider threat, operational...60 days Use of strong passwords Use of simple passwords` 10 A Family of Cybersecurity Maturity Models ES-C2M2 ONG -C2M2 C2M2 for IT Services F a c...11 Electricity Subsector Electricity portion of the energy sector Includes • Generation • Transmission • Distribution • Marketing 12 Model

  19. Understanding and Improving High Voltage Vacuum Insulators for Microsecond Pulses

    Energy Technology Data Exchange (ETDEWEB)

    Javedani, J B; Goerz, D A; Houck, T L; Lauer, E J; Speer, R D; Tully, L K; Vogtlin, G E; White, A D

    2007-03-05

    High voltage insulation is one of the main areas of pulsed power research and development, and dielectric breakdown is usually the limiting factor in attaining the highest possible performance in pulsed power devices. For many applications the delivery of pulsed power into a vacuum region is the most critical aspect of operation. The surface of an insulator exposed to vacuum can fail electrically at an applied field more than an order or magnitude below the bulk dielectric strength of the insulator. This mode of breakdown, called surface flashover, imposes serious limitations on the power flow into a vacuum region. This is especially troublesome for applications where high voltage conditioning of the insulator and electrodes is not practical and for applications where relatively long pulses, on the order of several microseconds, are required. The goal of this project is to establish a sound fundamental understanding of the mechanisms that lead to surface flashover, and then evaluate the most promising techniques to improve vacuum insulators and enable high voltage operation at stress levels near the intrinsic bulk breakdown limits of the material. The approach we proposed and followed was to develop this understanding through a combination of theoretical and computation methods coupled with experiments to validate and quantify expected behaviors. In this report we summarize our modeling and simulation efforts, theoretical studies, and experimental investigations. The computational work began by exploring the limits of commercially available codes and demonstrating methods to examine field enhancements and defect mechanisms at microscopic levels. Plasma simulations with particle codes used in conjunction with circuit models of the experimental apparatus enabled comparisons with experimental measurements. The large scale plasma (LSP) particle-in-cell (PIC) code was run on multiprocessor platforms and used to simulate expanding plasma conditions in vacuum gap regions

  20. Evaluation of SF6-alternative gas C5-PFK based on arc extinguishing performance and electric strength

    Science.gov (United States)

    Wu, Yi; Wang, Chunlin; Sun, Hao; Rong, Mingzhe; Murphy, Anthony Bruce; Li, Tianwei; Zhong, Jianying; Chen, Zhexin; Yang, Fei; Niu, Chunpin

    2017-09-01

    C5-PFK (C5-perfluoroketone, C5F10O) is under wide consideration as an environmentally-friendly alternative gas to SF6 in high-voltage applications, because of its superior insulation performance. The aim of this work is to study theoretically the arc extinguishing performance and electric strength of C5-PFK. The arc extinguishing performance of C5-PFK was evaluated by analyzing and comparing the thermophysical properties of C5-PFK, SF6, CF4, CO2 and N2 plasmas. It was difficult to obtain the species formed in C5-PFK plasmas because of the complex C5-PFK molecular decomposition process. In this work, the decomposition process of C5-PFK and the related species were analyzed by the bond energy analysis method. For the species for which parameters such as the partition function and the enthalpy of formation were not available, computational chemistry methods were used to obtain the required data. The collision integrals were calculated using the phenomenological potential model. Using these results, the local thermodynamic equilibrium composition at temperatures from 300 to 30 000 K at 1-10 atm of pure C5-PFK was calculated by the method of minimization of the Gibbs free energy, and the corresponding transport coefficients were calculated by Chapman-Enskog method. Through the comparison of the thermophysical properties, it was found that C5-PFK had similar characteristics to SF6, with large peaks in specific heat below 4500 K, indicating potentially good thermal interruption capability. However, the specific heat peak at 7000 K corresponding to CO decomposition may detract from the thermal interruption capability. Specific heat peaks at higher temperatures are associated with the breaking of double or triple bonds, and should be avoided if possible in the new alternative gases. The electric strength of C5-PFK was assessed using the molecular electrostatic potential, which can be accurately calculated or measured, and gives strong insights into important

  1. Multiple density layered insulator

    Science.gov (United States)

    Alger, Terry W.

    1994-01-01

    A multiple density layered insulator for use with a laser is disclosed wh provides at least two different insulation materials for a laser discharge tube, where the two insulation materials have different thermoconductivities. The multiple layer insulation materials provide for improved thermoconductivity capability for improved laser operation.

  2. Hydrogen storage in insulated pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, S.M.; Garcia-Villazana, O. [Lawrence Livermore National Lab., CA (United States)

    1998-08-01

    Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LH{sub 2}) or ambient-temperature compressed hydrogen (CH{sub 2}). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (lower energy requirement for hydrogen liquefaction and reduced evaporative losses). This paper shows an evaluation of the applicability of the insulated pressure vessels for light-duty vehicles. The paper shows an evaluation of evaporative losses and insulation requirements and a description of the current analysis and experimental plans for testing insulated pressure vessels. The results show significant advantages to the use of insulated pressure vessels for light-duty vehicles.

  3. Characterizations of realized metal-insulator-silicon-insulator-metal waveguides and nanochannel fabrication via insulator removal.

    Science.gov (United States)

    Kwon, Min-Suk; Shin, Jin-Soo; Shin, Sang-Yung; Lee, Wan-Gyu

    2012-09-24

    We investigate experimentally metal-insulator-silicon-insulator-metal (MISIM) waveguides that are fabricated by using fully standard CMOS technology. They are hybrid plasmonic waveguides, and they have a feature that their insulator is replaceable with functional material. We explain a fabrication process for them and discuss fabrication results based on 8-inch silicon-on-insulator wafers. We measured the propagation characteristics of the MISIM waveguides that were actually fabricated to be connected to Si photonic waveguides through symmetric and asymmetric couplers. When incident light from an optical source has transverse electric (TE) polarization and its wavelength is 1318 or 1554 nm, their propagation losses are between 0.2 and 0.3 dB/μm. Excess losses due to the symmetric couplers are around 0.5 dB, which are smaller than those due to the asymmetric couplers. Additional measurement results indicate that the MISIM waveguide supports a TE-polarized hybrid plasmonic mode. Finally, we explain a process of removing the insulator without affecting the remaining MISIM structure to fabricate ~30-nm-wide nanochannels which may be filled with functional material.

  4. The Insulation Properties of Oil-Impregnated Insulation Paper Reinforced with Nano-TiO2

    Directory of Open Access Journals (Sweden)

    Ruijin Liao

    2013-01-01

    Full Text Available Oil-impregnated insulation paper has been widely used in transformers because of its low cost and desirable physical and electrical properties. However, research to improve the insulation properties of oil-impregnated insulation paper is rarely found. In this paper, nano-TiO2 was used to stick to the surface of cellulose which was used to make insulation paper. After oil-impregnated insulation paper reinforced by nano-TiO2 was prepared, the tensile strength, breakdown strength, and dielectric properties of the oil-impregnated insulation paper were investigated to determine whether the modified paper had a better insulation performance. The results show that there were no major changes in tensile strength, and the value of the breakdown strength was greatly improved from 51.13 kV/mm to 61.78 kV/mm. Also, the values of the relative dielectric constant, the dielectric loss, and conductivity declined. The discussion reveals that nano-TiO2 plays a major role in the phenomenon. Because of the existence of nano-TiO2, the contact interface of cellulose and oil was changed, and a large number of shallow traps were produced. These shallow traps changed the insulation properties of oil-impregnated insulation paper. The results show that the proposed solution offers a new method to improve the properties of oil-impregnated insulation paper.

  5. Physical and electrical properties of induced high-k ZrHfO crystallization with ZrN cap by high power impulse magnetron sputtering for metal-gate metal-insulator-semiconductor structures

    Science.gov (United States)

    Tsai, Jung-Ruey; Juan, Pi-Chun; Lin, Cheng-Li; Lin, Guo-Cheng

    2017-01-01

    Metal-gate TiN/ZrN/ZrHfO/p-Si metal-insulator-semiconductor (MIS) structures have been fabricated in this work. The physical and electrical properties were characterized. The crystallization of high-k ZrHfO thin-film is induced by high power impulse magnetron sputtering (HIPIMS) during the deposition of ZrN capping layer. The binding energies and depth profiles were investigated by X-ray photoelectron spectroscopy (XPS). It is found that Zr and Hf out-diffusion from high-k dielectric in samples with HIPIMS is lesser than those in samples with the conventional DC magnetron sputtering (DCMS). The dielectric constant which strongly relates to the tetragonal phase becomes higher and the flatband voltage shift shows smaller by using the HIPIMS method than by the conventional DCMS. The cation and anion vacancies have been investigated by the defect reaction model.

  6. 168kV reduced-size gas insulated switch for Hekinan substation of Chubu Electric Power Co., Inc.; Chubu Denryoku (kabu) Hekinan hendensho 168kV shukushogata gas zetsuen kaihei sochi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-01-10

    Fuji Electric Co., Ltd., has delivered 13 units of 168kV reduced-size gas insulated switches (GIS) to the Hekinan substation of Chubu Electric Power Co., Inc. Their rated currents are 2000/3000/4000A, and they can withstand a short-time amperage of 40kA. The GIS introduced here is based on the excellent result achieved by the 168kV-rate GIS of the SDF type of Fuji Electric Co., Ltd., with its constituent devices reduced in size and composited, and its unit layout optimized. The new GIS occupies approximately 70% of what the conventional type requires for installation, and it weighs approximately 90% of the conventional type in mass. The new product may be separated into two parts, or integrated with the control panel, and the design is expected to shorten the on-site work time and the term of works. As for the number of parts, it is also reduced to approximately 80%, and this enhances GIS reliability. The 13 units were installed in September 1999, adjustment is now complete, and they are to come into service in May 2000. (translated by NEDO)

  7. Electrical and magnetic properties of n-Cd sub 1 sub - sub x Mn sub x Te close to the metal-insulator transition

    CERN Document Server

    Read, D E

    2001-01-01

    temperatures and in zero field an activated form of the conductivity is observed. In applied magnetic fields (B > 50 mT) Efros-ShkIovskii variable range hopping is observed in the insulating phase. These results are attributed to the formation of a hard gap in the density of states, having a magnetic origin. At higher fields an insulator-metal phase transition occurs. In the metallic phase the conductivity can be described by a quantum correction to the zero temperature conductivity due to the effect of electron-electron interactions. Results obtained before and after illumination are consistent with scaling theory of electron localisation, having a critical exponent close to unity, indicative of the importance of electron-electron interactions. A reduction in the value of the critical field is seen after increasing the carrier density (B sub c = 2.0 and 1.3 T for n = 3.3 and 3.8 x 10 sup 1 sup 7 cm sup - sup 3 respectively). At low temperatures an anisotropy in the resistivity has been measured for samples i...

  8. Electrical machines monitoring using partial discharges; Monitorizacion de maquinas electricas mediante descargas parciales

    Energy Technology Data Exchange (ETDEWEB)

    Cano, J. C.; Rodriguez Ruiz, S.

    2006-07-01

    Electrical Machines Monitoring is a philosophy that is being more and more accepted in maintenance, the application of these techniques has a lot of advantages as the life evaluation non-intrusively and the detection and evolution evaluation of defects. this paper presents the monitoring of electrical machines using the Partial Discharges technique, which allow the evaluation of insulation of Electrical Machines. Real Cases are included in the paper as samples in which this techniques has been useful to detecting defects. (Author)

  9. Insulation coordination for delta connected transformers

    Energy Technology Data Exchange (ETDEWEB)

    Keri, A.J.F.; Musa, Y.I.; Halladay, J.A. (American Electric Power Service Corp., Columbus, OH (United States))

    1994-04-01

    It is common practice to install only phase to ground surge arresters for transformer insulation protection against electrical stresses. However, this may not adequately protect the delta connected transformer phase to phase winding insulation. High phase to phase overvoltages at the transformer terminals, due to capacitor switching, have been reported. This paper describes the excessive phase to phase overvoltages that can also occur due to wave propagation and surge transfer through transformers. This paper points out the need for surge arrester arrangements that protect both, phase to phase and phase to ground transformer insulations. Surge arrester arrangements, selection criteria, installation practices, and application considerations are discussed in this paper.

  10. A critical evaluation of direct electrical protein detection methods

    NARCIS (Netherlands)

    Bergveld, Piet

    1991-01-01

    During the last decennia many protein-related electrical phenomena have been studied and applied in a variety of measuring systems, from simple metal electrodes with adsorbed proteins to sophisticated systems with lipid bilayers. Many of the investigations concern the monitoring of immuno reactions.

  11. Evaluation of Electrical and Thermal Conductivity of Polymeric ...

    African Journals Online (AJOL)

    PROF HORSFALL

    application was compressed in a wooden mold to form tablets of the doped polymers. On testing for the electrical and thermal conductivities of the doped polymers it was observed that both conductivities were greatly enhanced as the concentrations of the dopants increased. Hence it is evident that those polymeric materials ...

  12. Evaluation of electrical and thermal conductivity of polymeric wastes ...

    African Journals Online (AJOL)

    The mixture on melting with heat application was compressed in a wooden mold to form tablets of the doped polymers. On testing for the electrical and thermal conductivities of the doped polymers it was observed that both conductivities were greatly enhanced as the concentrations of the dopants increased. Hence it is ...

  13. Evaluation of full strength paper mill effluent for electricity generation ...

    African Journals Online (AJOL)

    0615306y

    2011-11-07

    Nov 7, 2011 ... renewable energy, have considered anaerobic treatment for the generation of volatile fatty acids, biogases. (Kaksonen et al., 2003; Najafpour et al., 2009) and direct generation of electricity in microbial fuel cells — MFCs. (Nimje et al., 2009; Cha et al., 2010; Kassongo and Togo,. 2010). In the latter, effluent ...

  14. Evaluation of reusable surface insulation for space shuttle over a range of heat-transfer rate and surface temperature

    Science.gov (United States)

    Chapman, A. J.

    1973-01-01

    Reusable surface insulation materials, which were developed as heat shields for the space shuttle, were tested over a range of conditions including heat-transfer rates between 160 and 620 kW/sq m. The lowest of these heating rates was in a range predicted for the space shuttle during reentry, and the highest was more than twice the predicted entry heating on shuttle areas where reusable surface insulation would be used. Individual specimens were tested repeatedly at increasingly severe conditions to determine the maximum heating rate and temperature capability. A silica-base material experienced only minimal degradation during repeated tests which included conditions twice as severe as predicted shuttle entry and withstood cumulative exposures three times longer than the best mullite material. Mullite-base materials cracked and experienced incipient melting at conditions within the range predicted for shuttle entry. Neither silica nor mullite materials consistently survived the test series with unbroken waterproof surfaces. Surface temperatures for a silica and a mullite material followed a trend expected for noncatalytic surfaces, whereas surface temperatures for a second mullite material appeared to follow a trend expected for a catalytic surface.

  15. Evaluation of all-electric secondary power for transport aircraft

    Science.gov (United States)

    Murray, W. E.; Feiner, L. J.; Flores, R. R.

    1992-01-01

    This report covers a study by Douglas Aircraft Company (DAC) of electrical power systems for advanced transport aircraft based upon an all-electric design concept. The concept would eliminate distributed hydraulic and pneumatic secondary power systems, and feature an expanded secondary electrical power system redesigned to supply power to the loads customarily supplied by hydraulic or pneumatic power. The initial study was based on an advanced 20-kHz electrical power transmission and distribution system, using a system architecture supplied by NASA-Lewis Research Center for twin-engine aircraft with many advanced power conversion concepts. NASA-LeRC later requested DAC to refocus the study on 400-Hz secondary power distribution. Subsequent work was based on a three-engine MD-11 aircraft, selected by DAC as a baseline system design that would provide data for the comparative cost/benefit analysis. The study concluded that the 20-kHz concept produced many expected benefits, and that the all-electric trijet weight savings on hardware redesign would be 2,304 pounds plus a 2.1-percent fuel reduction and resized for a total weight reduction of 11,000 pounds. Cost reductions for a fleet of 800 aircraft in a 15-year production program were estimated at $76.71 million for RDT&E; $2.74 million per aircrat for production; $9.84 million for nonrecurring expenses; $120,000 per aircraft for product support; and $300,000 per aircraft per year for operating and maintenance costs, giving a present value of $1.914 billion saved or a future value of $10.496 billion saved.

  16. Evaluation of the Electrical Resistance and Capacitance of a Di-Electric Electro-Active Polymer

    Science.gov (United States)

    Ng, Boon Chai; Lovhoiden, Gunnar; Magbanua, James

    Dielectric Electro Active Polymers (DEAP) have the potential of converting mechanical energy into electrical energy. DEAP consists of a silicone dielectric film material with a special corrugated surface and a very thin layer of metallic electrodes on both sides of the surface allowing for large mechanical deformations with low operating forces. This work examined how the DEAP capacitance and the electrode resistance were affected by repeated stress relaxation cycles.

  17. Electrical Bistabilities and Conduction Mechanisms of Nonvolatile Memories Based on a Polymethylsilsesquioxane Insulating Layer Containing CdSe/ZnS Quantum Dots

    Science.gov (United States)

    Ma, Zehao; Ooi, Poh Choon; Li, Fushan; Yun, Dong Yeol; Kim, Tae Whan

    2015-10-01

    Nonvolatile memory (NVM) devices based on a metal-insulator-metal structure consisting of CdSe/ZnS quantum dots embedded in polymethylsilsesquioxane dielectric layers were fabricated. The current-voltage ( I- V) curves showed a bistable current behavior and the presence of hysteresis. The current-time ( I- t) curves showed that the fabricated NVM memory devices were stable up to 1 × 104 s with a distinct ON/OFF ratio of 104 and were reprogrammable when the endurance test was performed. The extrapolation of the I- t curve to 105 s with corresponding current ON/OFF ratio 1 × 105 indicated a long performance stability of the NVM devices. Schottky emission, Poole-Frenkel emission, trapped-charge limited-current and Child-Langmuir law were proposed as the dominant conduction mechanisms for the fabricated NVM devices based on the obtained I- V characteristics.

  18. Temperature dependent electrical characterisation of Pt/HfO2/n-GaN metal-insulator-semiconductor (MIS Schottky diodes

    Directory of Open Access Journals (Sweden)

    Arjun Shetty

    2015-09-01

    Full Text Available This paper reports an improvement in Pt/n-GaN metal-semiconductor (MS Schottky diode characteristics by the introduction of a layer of HfO2 (5 nm between the metal and semiconductor interface. The resulting Pt/HfO2/n-GaN metal-insulator-semiconductor (MIS Schottky diode showed an increase in rectification ratio from 35.9 to 98.9(@ 2V, increase in barrier height (0.52 eV to 0.63eV and a reduction in ideality factor (2.1 to 1.3 as compared to the MS Schottky. Epitaxial n-type GaN films of thickness 300nm were grown using plasma assisted molecular beam epitaxy (PAMBE. The crystalline and optical qualities of the films were confirmed using high resolution X-ray diffraction and photoluminescence measurements. Metal-semiconductor (Pt/n-GaN and metal-insulator-semiconductor (Pt/HfO2/n-GaN Schottky diodes were fabricated. To gain further understanding of the Pt/HfO2/GaN interface, I-V characterisation was carried out on the MIS Schottky diode over a temperature range of 150 K to 370 K. The barrier height was found to increase (0.3 eV to 0.79 eV and the ideality factor decreased (3.6 to 1.2 with increase in temperature from 150 K to 370 K. This temperature dependence was attributed to the inhomogeneous nature of the contact and the explanation was validated by fitting the experimental data into a Gaussian distribution of barrier heights.

  19. Nonlinear conduction phenomena in the Mott insulator Ca2RuO4

    Science.gov (United States)

    Okazaki, Ryuji; Nishina, Yasuo; Yasui, Yukio; Terasaki, Ichiro; Nakamura, Fumihiko; Kimura, Yusaku; Sakaki, Mariko; Suzuki, Takashi

    2012-02-01

    The 4d-electron Mott insulator Ca2RuO4 has attracted considerable attention because of its rich electronic states dramatically varied by temperature change, pressure, and isovalent Sr substitution. Recently, Nakamura et al. reported an intriguing result of current-voltage characteristics in Ca2RuO4 and found an E-induced insulator-to-metal transition caused by relatively low electric field E ˜ 50 V/cm [1]. In this study we investigate the nonlinear conduction phenomena in the Mott insulating phase of Ca2RuO4 with a proper evaluation for self-heating effects. By utilizing a non-contact infrared thermometer, sample temperature was accurately determined even in the presence of large Joule heating. The resistivity shows a typical insulating behavior featured by thermal activation with an energy gap, but clearly depends on the applied currents. The result is highlighted by a strong suppression of the energy gap by the electrical currents. A striking similarity to the current dependence of charge-order gap in organic insulators is discussed in terms of the nonequilibrium phase transition. [4pt] [1] F. Nakamura et al., (submitted).

  20. A Study of Insulation Design of a Gas Transformer Using Extra Turns

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Woo Heng; Ha, Yong Sik [Hyosung Industries Co., Ltd (Korea); Hong, Jung Pyo; Kim, Gyu Tak [Changwon University, Changwon (Korea)

    2001-03-01

    This paper deals with the electrical insulation design of a gas insulated power transformer based on extra turns method satisfying the impulse test performed in the worst condition. The calculation of electrical strength in insulation structure was done by 2D finite element method. The gas insulated power transformer was manufactured by selecting the optimum arrangement among design results. the validity of the design result is verified by the impulse test of manufactured machine. (author). 11 refs., 11 figs., 2 tabs.

  1. Comparative Evaluation of Tactile Sensation by Electrical and Mechanical Stimulation.

    Science.gov (United States)

    Yem, Vibol; Kajimoto, Hiroyuki

    2017-01-01

    An electrotactile display is a tactile interface that provides tactile perception by passing electrical current through the surface of the skin. It is actively used instead of mechanical tactile displays for tactile feedback because of several advantages such as its small and thin size, light weight, and high responsiveness. However, the similarities and differences between these sensations is still not clear. This study directly compares the intensity sensation of electrotactile stimulation to that of mechanical stimulation, and investigates the characteristic sensation of anodic and cathodic stimulation. In the experiment, participants underwent a 30 pps electrotactile stimulus every one second to their middle finger, and were asked to match this intensity by adjusting the intensity of a mechanical tactile stimulus to an index finger. The results showed that anodic stimulation mainly produced vibration sensation, whereas cathodic sensation produced both vibration and pressure sensations. Relatively low pressure sensation was also observed for anodic stimulation but it remains low, regardless of the increasing of electrical intensity.

  2. Evaluation of 2005 Honda Accord Hybrid Electric Drive System

    Energy Technology Data Exchange (ETDEWEB)

    Staunton, R.H.; Burress, T.A.; Marlino, L.D.

    2006-09-11

    The Hybrid Electric Vehicle (HEV) program officially began in 1993 as a five-year, cost-shared partnership between the U.S. Department of Energy (DOE) and American auto manufacturers: General Motors, Ford, and Daimler Chrysler. Currently, HEV research and development is conducted by DOE through its FreedomCAR and Vehicle Technologies (FCVT) program. The mission of the FCVT program is to develop more energy efficient and environmentally friendly highway transportation technologies. Program activities include research, development, demonstration, testing, technology validation, and technology transfer. These activities are aimed at developing technologies that can be domestically produced in a clean and cost-competitive manner. The vehicle systems technologies subprogram, which is one of four subprograms under the FCVT program, supports the efforts of the FreedomCAR through a three-phase approach [1] intended to: (1) Identify overall propulsion and vehicle-related needs by analyzing programmatic goals and reviewing industry's recommendations and requirements, then develop the appropriate technical targets for systems, subsystems, and component research and development activities; (2) Develop and validate individual subsystems and components, including electric motors, emission control devices, battery systems, power electronics, accessories, and devices to reduce parasitic losses; and (3) Determine how well the components and subassemblies work together in a vehicle environment or as a complete propulsion system and whether the efficiency and performance targets at the vehicle level have been achieved. The research performed under the vehicle systems subprogram will help remove technical and cost barriers to enable technology for use in such advanced vehicles as hybrid electric, plug-in electric, and fuel-cell-powered vehicles.

  3. Evaluation of electrical conductivity of the fertiliser solution on ...

    African Journals Online (AJOL)

    The effects of three fertiliser solutions (20:20:20, 15:5:25 and 12:30:10 NPK) with electrical conductivity (EC) of 1, 1.5 or 2 mS cm-1 on growth and flowering of Cymbidium 'Sleeping Nymph' were investigated over three years. One-year-old tissue-cultured propagules of 'Sleeping Nymph' were planted singly in plastic pots in ...

  4. Generation of Electrical Power from Stimulated Muscle Contractions Evaluated

    Science.gov (United States)

    Lewandowski, Beth; Kilgore, Kevin; Ercegovic, David B.

    2004-01-01

    This project is a collaborative effort between NASA Glenn Research Center's Revolutionary Aeropropulsion Concepts (RAC) Project, part of the NASA Aerospace Propulsion and Power Program of the Aerospace Technology Enterprise, and Case Western Reserve University's Cleveland Functional Electrical Stimulation (FES) Center. The RAC Project foresees implantable power requirements for future applications such as organically based sensor platforms and robotics that can interface with the human senses. One of the goals of the FES Center is to develop a totally implantable neural prosthesis. This goal is based on feedback from patients who would prefer a system with an internal power source over the currently used system with an external power source. The conversion system under investigation would transform the energy produced from a stimulated muscle contraction into electrical energy. We hypothesize that the output power of the system will be greater than the input power necessary to initiate, sustain, and control the electrical conversion system because of the stored potential energy of the muscle. If the system can be made biocompatible, durable, and with the potential for sustained use, then the biological power source will be a viable solution.

  5. A new experimental device to evaluate eye ulcers using a multispectral electrical impedance technique

    Science.gov (United States)

    Bellotti, Mariela I.; Bast, Walter; Berra, Alejandro; Bonetto, Fabián J.

    2011-07-01

    We present a novel experimental technique to determine eye ulcers in animals using a spectral electrical impedance technique. We expect that this technique will be useful in dry eye syndrome. We used a sensor that is basically a platinum (Pt) microelectrode electrically insulated by glass from a cylindrical stainless steel counter-electrode. This sensor was applied to the naked eye of New Zealand rabbits (2.0-3.5 kg in weight). Whereas half of the eyes were normal (control), we applied to the remainder a few drops of 20% (v/v) alcohol to produce an ulcer in the eye. Using a multispectral electrical impedance system we measured ulcerated and control eyes and observed significant difference between normal and pathological samples. We also investigated the effects of different applied pressures and natural degradation of initially normal eyes as a function of time. We believe that this technique could be sufficiently sensitive and repetitive to help diagnose ocular surface diseases such as dry eye syndrome.

  6. Guidelines for insulation coordination in live working

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The Guide contains the main aspects to be taken into consideration in the assessment of insulation coordination during live working on overhead transmission lines; the basis rules and influence factors for the determination of the minimum distances to be maintained between parts at different potential, including the worker himself, are given as well as for the evaluation of the risk of insulation failure. (authors)

  7. Evaluation of Two CEDA Weatherization Pilot Implementations of an Exterior Insulation and Over-Clad Retrofit Strategy for Residential Masonry Buildings in Chicago

    Energy Technology Data Exchange (ETDEWEB)

    Neuhauser, Ken [Building Science Corporation, Somerville, MA (United States)

    2013-08-01

    This project examines the implementation of an exterior insulation and over-clad strategy for brick masonry buildings in Chicago—a free-standing two story two-family dwelling and a larger free-standing multifamily building. The test homes selected for this research represent predominant housing types for the Chicago area, in which high heating energy use typical in these buildings threaten housing affordability, and uninsulated mass masonry wall assemblies are uncomfortable for residents. In this project, the Community and Economic Development Association of Cook County, Inc. (CEDA) has secured a Sustainable Energy Resources for Consumers (SERC) innovation grant sponsored by DOE to pursue a pilot implementation of innovative approaches to retrofit in masonry wall enclosures. The retrofit measures are evaluated in terms of feasibility, cost and performance. Through observations of the strategies implemented, the research described in this report identifies measures critical to performance as well as conditions for wider adoption. The research also identifies common factors that must be considered in determining whether the exterior insulation and over-clad strategy is appropriate for the building.

  8. Evaluation of electric properties of cement mortars containing pozzolans

    Directory of Open Access Journals (Sweden)

    Cruz, J. M.

    2011-03-01

    Full Text Available In this paper the evolution of the microstructure of Portland cement mortar is analyzed, by using electrical impedance measurements. Cement mortars are compared without and with two pozzolanic substitutions: spent fluid catalytic cracking catalyst (FCC and metakaolin (MK. The measurement method is described and the model for analyzing the electrical impedance spectra is developed. Three electrical parameters are defined: electrical resistivity, capacitance exponent, and capacitive factor. The results show a significant increase in resistivity of the mortars with pozzolans after 7 days of curing, especially in mortars with MK. This increase is correlated with lime-fixing by the pozzolans. The capacitive properties evolve differently at early age, but reach the same values after 148 days. The electrical and mineralogical data show that the evolution of the microstructure in the mortar with MK starts before it does in the mortars with FCC and that the final microstructure becomes different.

    En este trabajo se analiza la microestructura de morteros de cemento Portland, mediante medidas de impedancia eléctrica. Se comparan morteros de cemento sin y con dos sustituciones puzolánicas: residuo de catalizador de craqueo catalítico (FCC y metacaolín (MK. Se describe el método de medida y se desarrolla el modelo de análisis de los espectros de impedancia eléctrica. Se definen tres parámetros eléctricos: resistividad eléctrica, exponente capacitivo, y factor capacitivo. Se observa un aumento importante de la resistividad de los morteros con puzolana a partir de los 7 días de curado, sobre todo en morteros con MK. Este aumento está correlacionado con la fijación de cal de las puzolanas. Las propiedades capacitivas son diferentes a edad temprana, pero se igualan a los 148 días. Los resultados eléctricos y mineralógicos muestran que la evolución microestructural comienza antes en los morteros con MK que con FCC y que la microestructura

  9. Evaluation of the induced electric field and compliance procedure for a wireless power transfer system in an electrical vehicle.

    Science.gov (United States)

    Laakso, Ilkka; Hirata, Akimasa

    2013-11-07

    In this study, an induced electric field in a human body is evaluated for the magnetic field leaked from a wireless power transfer system for charging an electrical vehicle. The magnetic field from the wireless power transfer system is modelled computationally, and its effectiveness is confirmed by comparison with the field measured in a previous study. The induced electric field in a human standing around the vehicle is smaller than the allowable limit prescribed in international guidelines, although the magnetic field strength in the human body is locally higher than the allowable external field strength. Correlation between the external magnetic field and the induced electric field is confirmed to be reasonable at least in the standing posture, which is the case discussed in the international standard. Based on this finding, we discussed and confirmed the applicability of a three-point magnetic field measurement at heights of 0.5, 1.0, and 1.5 m for safety compliance.

  10. Performance Evaluation of an Autonomous Photovoltaic System for Recharging Electrical Vehicle Batteries

    OpenAIRE

    Benaouadj, M.; Aboubou, A.; Ayad, M.Y; Becherif, M.; Akhrif, O.

    2015-01-01

    – This paper deals with the performance evaluation of an autonomous photovoltaic system for recharging (with electrical power produced by photovoltaic panels) Lithium-ion batteries for an electrical vehicle. In this system, the power flow control is performed via a DC-DC converter using a Maximum Power Point Tracking (MPPT) technique. The performance evaluation is according to two operation modes: under degraded and optimal conditions

  11. Evaluating multivariate GARCH models in the Nordic electricity markets

    Energy Technology Data Exchange (ETDEWEB)

    Malo, P.; Kanto, A.

    2005-07-01

    This paper considers a variety of specification tests for multivariate GARCH models that are used in dynamic hedging in the electricity markets. The test statistics include the robust conditional moments tests for sign-size bias along with the recently introduced copula tests for an appropriate dependence structure. We consider this effort worthwhile, since quite often the tests of multivariate GARCH models are easily omitted and the models become selected ad-hoc depending on the results they generate. Hedging performance comparisons, in terms of unconditional and conditional ex-post variance portfolio reduction, are conducted. (orig.)

  12. Evaluation of Electric Power Saving Due to Oil Slime Cleaning in Linear Part of Oil Pipeline

    Directory of Open Access Journals (Sweden)

    V. A. Anischenko

    2006-01-01

    Full Text Available The paper presents evaluation method of electric power saving due to periodical cleaning of oil pipeline linear part which is intended to increase an equivalent diameter of the pipeline. The proposed method is based on statistical model developed on the basis of 24-hourly statistics reflecting modes of electric power consumption that take place at an enterprise. Electric power saving is evaluated according to changes of an equivalent diameter in the process of oil pipeline cleaning (and after this process with respect to changes of an equivalent diameter without pipeline cleaning.

  13. Experimental Evaluation of Electric Power Grid Visualization Tools in the EIOC

    Energy Technology Data Exchange (ETDEWEB)

    Greitzer, Frank L.; Dauenhauer, Peter M.; Wierks, Tamara G.; Podmore, Robin; Dalton, Angela C.

    2009-12-01

    The present study follows an initial human factors evaluation of four electric power grid visualization tools and reports on an empirical evaluation of two of the four tools: Graphical Contingency Analysis, and Phasor State Estimator. The evaluation was conducted within specific experimental studies designed to measure the impact on decision making performance.

  14. Band structure engineering in topological insulator based heterostructures.

    Science.gov (United States)

    Menshchikova, T V; Otrokov, M M; Tsirkin, S S; Samorokov, D A; Bebneva, V V; Ernst, A; Kuznetsov, V M; Chulkov, E V

    2013-01-01

    The ability to engineer an electronic band structure of topological insulators would allow the production of topological materials with tailor-made properties. Using ab initio calculations, we show a promising way to control the conducting surface state in topological insulator based heterostructures representing an insulator ultrathin films on the topological insulator substrates. Because of a specific relation between work functions and band gaps of the topological insulator substrate and the insulator ultrathin film overlayer, a sizable shift of the Dirac point occurs resulting in a significant increase in the number of the topological surface state charge carriers as compared to that of the substrate itself. Such an effect can also be realized by applying the external electric field that allows a gradual tuning of the topological surface state. A simultaneous use of both approaches makes it possible to obtain a topological insulator based heterostructure with a highly tunable topological surface state.

  15. Dielectric insulation and high-voltage issues

    CERN Document Server

    Tommasini, D

    2010-01-01

    Electrical faults are in most cases dramatic events for magnets, due to the large stored energy which is potentially available to be dissipated at the fault location. After a reminder of the principles of electrostatics in Section 1, the basic mechanisms of conduction and breakdown in dielectrics are summarized in Section 2. Section 3 introduces the types and function of the electrical insulation in magnets, and Section 4 its relevant failure mechanisms. Section 5 deals with ageing and, finally, Section 6 gives some principles for testing. Though the School specifically dealt with warm magnets, for completeness some principles of dielectric insulation for superconducting accelerator magnets are briefly summarized in a dedicated appendix.

  16. Ultra High Voltage Propellant Isolators and Insulators for JIMO Ion Thrusters

    Science.gov (United States)

    Banks, Bruce A.; Gaier, James R.; Hung, Ching-Cheh; Walters, Patty A.; Sechkar, Ed; Panko, Scott; Kamiotis, Christina A.

    2004-01-01

    Within NASA's Project Prometheus, high specific impulse ion thrusters for electric propulsion of spacecraft for the proposed Jupiter Icy Moon Orbiter (JIMO) mission to three of Jupiter's moons: Callisto, Ganymede and Europa will require high voltage operation to meet mission propulsion. The anticipated approx.6,500 volt net ion energy will require electrical insulation and propellant isolation which must exceed that used successfully by the NASA Solar Electric Propulsion Technology Readiness (NSTAR) Deep Space 1 mission thruster by a factor of approx.6. Xenon propellant isolator prototypes that operate at near one atmosphere and prototypes that operate at low pressures (Insulators used to mount the thrusters as well as those needed to support the ion optics have also been designed and are under evaluation. Isolator and insulator concepts, design issues, design guidelines, fabrication considerations and performance issues are presented. The objective of the investigation was to identify candidate isolators and insulators that are sufficiently robust to perform durably and reliably during the proposed JIMO mission.

  17. Fractal analysis of the electrical discharges' surface paths in polymeric insulation considering different pollution levels; Analisis fractal de las trayectorias de descargas electricas superficiales en aislamiento polimerico considerando diferentes niveles de contaminacion

    Energy Technology Data Exchange (ETDEWEB)

    Palacios Lopez, Arturo

    2002-07-01

    In this thesis tree patterns of superficial breakdown in polymeric insulator of Silicon Rubber are generated. Experimental arrangement rod-rod was used on the basis of norm ASTM D 2303-85. Pollution levels on the basis of norm IEC 507 were also used. The experimental values of Fractal Dimension for each case of pollution were reported. A self similar method called Box Counting for the fractal dimension calculus and for the self affine methods an R/S and Variogram were used. According to the results, it was concluded that the tree patterns of superficial electric breakdown in Silicon Rubber is self similar and its value does not depend on the degree of pollution, that is equivalent to the concentration of salt for liter of water or to the Equivalent Salt Deposition (ESDD), in the surface of an insulator. [Spanish] En el presente trabajo se inducen descargas electricas superficiales en un aislamiento polimerico de Hule Silicon, el arreglo experimental que se utilice es punta-punta con base en la norma ASTM D 2303-85 y los niveles de contaminacion con base en la norma IEC 507. Se reportan los valores experimentales de la Dimension Fractal para cada caso de contaminacion, se utilice el metodo auto similar de conteo de cuadros, para el calculo de la Dimension Fractal y para metodos auto afines se utilice analisis R/S y variograma. Con los resultados obtenidos se concluye que la trayectoria de la descarga electrica superficial en un polimero de Hule Silicon es auto similar y su valor no depende del grado de contaminacion, el cual es equivalente a la concentracion de gramos de sal por litro de agua o a la densidad de sal depositada (DESD), en la superficie de un aislador.

  18. Study of Composite Insulator Sheds Subjected to Wheel Test

    OpenAIRE

    Mackiewicz M.; Mikulski J.L.; Wańkowicz J.; Kucharski S.; Ranachowski P.; Ranachowski Z.

    2017-01-01

    The paper presents investigation of the properties of the surface and the material stiffness – flexibility of series of samples taken from the sheds of the composite insulators. The insulators were previously subjected to wheel test. The wheel test and 1000 h salt fog test are regarded as alternative examination of the material resistance to the effects of electrical surface discharges. There were investigated two series of the samples of the composite insulators sheds. Examined specimens, ma...

  19. Explosion resistant insulator and method of making same

    Science.gov (United States)

    Meyer, Jeffry R.; Billings, Jr., John S.; Spindle, Harvey E.; Hofmann, Charles F.

    1983-01-01

    An electrical insulator assembly and method of manufacturing same, having a generally cylindrical or conical body portion formed of a breakable cast solid insulation system and a reinforcing member having a corrugated configuration and formed of a web or mesh type reinforcing fabric. When the breakable body member has been broken, the corrugated configured reinforcing web member provides a path of escape for pressurized insulating fluid while limiting the movement of body member fragments in the direction of escape of the pressurized fluid.

  20. From a normal insulator to a topological insulator in plumbene

    Science.gov (United States)

    Yu, Xiang-Long; Huang, Li; Wu, Jiansheng

    2017-03-01

    Plumbene, similar to silicene, has a buckled honeycomb structure with a large band gap (˜400 meV). All previous studies have shown that it is a normal insulator. Here, we perform first-principles calculations and employ a sixteen-band tight-binding model with nearest-neighbor and next-nearest-neighbor hopping terms to investigate electronic structures and topological properties of the plumbene monolayer. We find that it can become a topological insulator with a large bulk gap (˜200 meV) through electron doping, and the nontrivial state is very robust with respect to external strain. Plumbene can be an ideal candidate for realizing the quantum spin Hall effect at room temperature. By investigating effects of external electric and magnetic fields on electronic structures and transport properties of plumbene, we present two rich phase diagrams with and without electron doping and propose a theoretical design for a four-state spin-valley filter.

  1. Quality labels for retrofit cavity wall insulation : a comparative analysis

    NARCIS (Netherlands)

    Rovers, Twan Johannes Hendrikus; Entrop, Alexis Gerardus; Halman, Johannes I.M.

    2017-01-01

    Retrofit cavity wall insulation can be exerted to reduce the energy use for space heating and cooling of existing buildings. In multiple countries, quality labels have emerged for this insulation service. In this research project, an evaluation framework for cavity wall insulation is developed by

  2. Limiting oxygen concentration for extinction of upward spreading flames over inclined thin polyethylene-insulated NiCr electrical wires with opposed-flow under normal- and micro-gravity

    KAUST Repository

    Hu, Longhua

    2016-10-02

    Materials, such as electrical wire, used in spacecraft must pass stringent fire safety standards. Tests for such standards are typically performed under normal gravity conditions and then extended to applications under microgravity conditions. The experiments reported here used polyethylene (PE)-insulated (thickness of 0.15 mm) Nichrome (NiCr)-core (diameter of 0.5 mm) electrical wires. Limiting oxygen concentrations (LOC) at extinction were measured for upward spreading flame at various forced opposed-flow (downward) speeds (0−25 cm/s) at several inclination angles (0−75°) under normal gravity conditions. The differences from those previously obtained under microgravity conditions were quantified and correlated to provide a reference for the development of fire safety test standards for electrical wires to be used in space exploration. It was found that as the opposed-flow speed increased for a specified inclination angle (except the horizontal case), LOC first increased, then decreased and finally increased again. The first local maximum of this LOC variation corresponded to a critical forced flow speed resulted from the change in flame spread pattern from concurrent to counter-current type. This critical forced flow speed correlated well with the buoyancy-induced flow speed component in the wire\\'s direction when the flame base width along the wire was used as a characteristic length scale. LOC was generally higher under the normal gravity than under the microgravity and the difference between the two decreased as the opposed-flow speed increases, following a reasonably linear trend at relatively higher flow speeds (over 10 cm/s). The decrease in the difference in LOC under normal- and microgravity conditions as the opposed-flow speed increases correlated well with the gravity acceleration component in the wire\\'s direction, providing a measure to extend LOC determined by the tests under normal gravity conditions (at various inclination angles and opposed

  3. Evaluating an electricity and magnetism assessment tool: Brief electricity and magnetism assessment

    National Research Council Canada - National Science Library

    Ding, Lin; Chabay, Ruth; Sherwood, Bruce; Beichner, Robert

    2006-01-01

    ... and magnetism concepts covered in college-level calculus-based introductory physics courses. To evaluate the reliability and discriminatory power of this assessment tool, we performed statistical tests focusing both on item analyses...

  4. Electrical engineer's reference book

    CERN Document Server

    Laughton, M A

    1985-01-01

    Electrical Engineer's Reference Book, Fourteenth Edition focuses on electrical engineering. The book first discusses units, mathematics, and physical quantities, including the international unit system, physical properties, and electricity. The text also looks at network and control systems analysis. The book examines materials used in electrical engineering. Topics include conducting materials, superconductors, silicon, insulating materials, electrical steels, and soft irons and relay steels. The text underscores electrical metrology and instrumentation, steam-generating plants, turbines

  5. Human Factors Evaluation of Advanced Electric Power Grid Visualization Tools

    Energy Technology Data Exchange (ETDEWEB)

    Greitzer, Frank L.; Dauenhauer, Peter M.; Wierks, Tamara G.; Podmore, Robin

    2009-04-01

    This report describes initial human factors evaluation of four visualization tools (Graphical Contingency Analysis, Force Directed Graphs, Phasor State Estimator and Mode Meter/ Mode Shapes) developed by PNNL, and proposed test plans that may be implemented to evaluate their utility in scenario-based experiments.

  6. Performance evaluation of a transformerless multiphase electric submersible pump system

    Directory of Open Access Journals (Sweden)

    Ahmed A. Hakeem

    2014-08-01

    Full Text Available Using of low-voltage variable-frequency drive followed by a step-up transformer is the most preferable way to feed an electrical submersible pump motor. The existence of long feeder between the motor and drive systems usually causes over-voltage problems because of the travelling wave phenomenon, which makes the employment of filter networks on the motor or inverter terminals mandatory. The so-called boost-inverter inherently can solve this problem with filter-less operation as it offers a direct sinusoidal output voltage. As boost inverters have voltage boosting capability, it can provide a transformer-less operation as well. This study investigates the performance of a five-phase modular winding induction machine fed from a boost-inverter through a long feeder. A simulation study using a 1000 Hp system and experimental investigation on a 1 Hp prototype machine are used to support the presented approach.

  7. Estudo da viabilidade de obtenção de isoladores elétricos a partir de resíduo de esmaltação Study of the viability for obtaining electric insulators from enameling waste

    Directory of Open Access Journals (Sweden)

    F. J. P. Sousa

    2004-09-01

    Full Text Available A gestão racional de resíduos industriais é um dos sérios problemas da sociedade atual. O presente trabalho tem por objetivo propor uma alternativa para o aproveitamento do resíduo de esmaltação da empresa Portinari, grupo Cecrisa S.A, por meio da utilização desse resíduo como principal componente em massas cerâmicas para obtenção de isoladores elétricos de distribuição secundária. Foram estudadas formulações contendo no mínimo 50% de resíduo e quantidades variáveis de alumina, feldspato potássico e de quartzo. O resíduo bruto foi primeiramente beneficiado e submetido às analises química, térmica e mineralógica para fins de caracterização. Adotou-se o processo de conformação plástica por torneamento para fabricação das amostras a verde, as quais foram secadas ao ar livre. As amostras obtidas foram submetidas a um ciclo térmico previamente indicado pela curva de gresificação do resíduo. Por fim, após a queima, os protótipos foram ensaiados quanto à rigidez dielétrica. Os resultados indicaram a compatibilidade técnica dos mesmos considerando o uso como isolador.Wise management of industrial wastes is one of the most serious problems in today´s society. The aim of the present work is to suggest an alternative way to reuse the enameling waste of Company Portinari Company, Cecrisa S.A, as major component in ceramic masses to the manufacturing of electric insulators. Formulations with variable amounts of alumina, potassic feldspar and quartz were used, all containing at least 50% waste. The crude waste was firstly treated and then characterized by chemical and mineralogical analysis. The plastic molding process was used in order to produce the green samples, which were left to dry. The samples were submitted to a firing cycle previously indicated by a gresification curve for the waste. After that, the produced samples were submitted to a final test in order to estimate their dielectric rupture tension. The

  8. Insulating and sheathing materials of electric and optical cables: common test methods part 4-1: methods specific to polyethylene and polypropylene compounds – resistance to environmental stress cracking – measurement of the melt flow index – carbon black and/or mineral filler content measurement in polyethylene by direct combustion – measurement of carbon black content by thermogravimetric analysis (TGA) – assessment of carbon black dispersion in polyethylene using a microscope

    CERN Document Server

    International Electrotechnical Commission. Geneva

    2004-01-01

    Specifies the test methods to be used for testing polymeric insulating and sheathing materials of electric cables for power distribution and telecommunications including cables used on ships. Gives the methods for measurements of the resistance to environmental stress cracking, for wrapping test after thermal ageing in air, for measurement of melt flow index and for measurement of carbon black and/or mineral filler content, which apply to PE and PP coumpounds, including cellular compounds and foam skin for insulation.

  9. Evaluation of electricity generation from lignin residue and biogas in cellulosic ethanol production.

    Science.gov (United States)

    Liu, Gang; Bao, Jie

    2017-11-01

    This study takes the first insight on the rigorous evaluation of electricity generation based on the experimentally measured higher heating value (HHV) of lignin residue, as well as the chemical oxygen demand (COD) and biological oxygen demand (BOD 5 ) of wastewater. For producing one metric ton of ethanol fuel from five typical lignocellulose substrates, including corn stover, wheat straw, rice straw, sugarcane bagasse and poplar sawdust, 1.26-1.85tons of dry lignin residue is generated from biorefining process and 0.19-0.27tons of biogas is generated from anaerobic digestion of wastewater, equivalent to 4335-5981kWh and 1946-2795kWh of electricity by combustion of the generated lignin residue and biogas, respectively. The electricity generation not only sufficiently meets the electricity needs of process requirement, but also generates more than half of electricity surplus selling to the grid. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. High Performance Slab-on-Grade Foundation Insulation Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Louise F. [NorthernSTAR, St. Paul, MN (United States); Mosiman, Garrett E. [NorthernSTAR, St. Paul, MN (United States)

    2015-09-01

    ?A more accurate assessment of SOG foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulation at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated). The optimum insulation strategy was applied to single and multi-family residential buildings in climate zone 4 - 7. The highest site energy savings of 5% was realized for a single family home in Duluth, MN, and the lowest savings of 1.4 % for a 4-unit townhouse in Richmond, VA. SOG foundation insulation retrofit simple paybacks ranged from 18 to 47 years. There are other benefits of SOG foundation insulation resulting from the increase in the slab surface temperatures. These include increased occupant thermal comfort, and a decrease in slab surface condensation particularly around the slab perimeter.

  11. ESTIMATION OF INSULATOR CONTAMINATIONS BY MEANS OF REMOTE SENSING TECHNIQUE

    Directory of Open Access Journals (Sweden)

    G. Han

    2016-06-01

    Full Text Available The accurate estimation of deposits adhering on insulators is critical to prevent pollution flashovers which cause huge costs worldwide. The traditional evaluation method of insulator contaminations (IC is based sparse manual in-situ measurements, resulting in insufficient spatial representativeness and poor timeliness. Filling that gap, we proposed a novel evaluation framework of IC based on remote sensing and data mining. Varieties of products derived from satellite data, such as aerosol optical depth (AOD, digital elevation model (DEM, land use and land cover and normalized difference vegetation index were obtained to estimate the severity of IC along with the necessary field investigation inventory (pollution sources, ambient atmosphere and meteorological data. Rough set theory was utilized to minimize input sets under the prerequisite that the resultant set is equivalent to the full sets in terms of the decision ability to distinguish severity levels of IC. We found that AOD, the strength of pollution source and the precipitation are the top 3 decisive factors to estimate insulator contaminations. On that basis, different classification algorithm such as mahalanobis minimum distance, support vector machine (SVM and maximum likelihood method were utilized to estimate severity levels of IC. 10-fold cross-validation was carried out to evaluate the performances of different methods. SVM yielded the best overall accuracy among three algorithms. An overall accuracy of more than 70% was witnessed, suggesting a promising application of remote sensing in power maintenance. To our knowledge, this is the first trial to introduce remote sensing and relevant data analysis technique into the estimation of electrical insulator contaminations.

  12. Instrumentation Requirements for the Engineering Evaluation of Nuclear-Electric Spacecraft

    Science.gov (United States)

    Apel, W. C.

    1961-01-01

    Spacecraft employing nuclear-electric propulsion are being proposed for missions to Venus and distances beyond. These spacecraft utilize a nuclear reactor to provide thermal energy to a turboalternator which generates electric power for an ion motor and the other spacecraft systems. This Report discusses the instrumentation and communications system needed to evaluate a nuclear-electric spacecraft in flight, along with the problems expected. A representative spacecraft design is presented, which leads to a discussion of the instrumentation needed to evaluate such a spacecraft. A basic communications system is considered for transmitting the spacecraft data to Earth. The instrumentation and communications system, as well as all electronic systems on a nuclear-electric spacecraft, will be operating in high temperature and nuclear-radiation environments. The problems caused by these environments are discussed, and possible solutions are offered.

  13. Complex Evaluation of Light Sources in Case of Electric Power Cost Increase

    Directory of Open Access Journals (Sweden)

    Y. N. Kolesnik

    2008-01-01

    Full Text Available The paper gives complex evaluation of efficiency of incandescent lamps, luminescent and light-emitting-diode (LED light sources in case of electric power price increase. On the basis of experimental table lamp electric power indices of light-emitting-diode (LED light sources with equivalent luminous flux have been determined. Dependences of main indices of economic efficiency of various light sources on their operational regimes have been obtained and rate of influence on these indices of electric power price increase have been determined. Economically justified variants and conditions for application of various light sources have been substantiated.

  14. Evaluation of Electrical Stimulus Current Applied to Retina Cells for Retinal Prosthesis

    Science.gov (United States)

    Motonami, Keita; Watanabe, Taiichiro; Deguchi, Jun; Fukushima, Takafumi; Tomita, Hiroshi; Sugano, Eriko; Sato, Manami; Kurino, Hiroyuki; Tamai, Makoto; Koyanagi, Mitsumasa

    2006-04-01

    We have proposed a novel multilayer stacked retinal prosthesis chip based on three-dimensional integration technology. Implantable stimulus electrode arrays in polyimide flexible cables were fabricated for the electrical stimulation of the retina. To evaluate optimal retinal stimulus current, electrically evoked potential (EEP) was recorded in animal experiments using Japanese white rabbits. The EEP waveform was compared with visually evoked potential (VEP) waveform. The amplitude of the recorded EEP increased with stimulus current. The EEP waveform shows a similar behavior to the VEP waveform, indicating that the electrical stimulation of the retina can be exploited for the blind to perceive incident light to the retina.

  15. Electric air filtration: theory, laboratory studies, hardware development, and field evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Bergman, W.; Biermann, A.; Kuhl, W.; Lum, B.; Bogdanoff, A.; Hebard, H.; Hall, M.; Banks, D.; Mazumder, M.; Johnson, J.

    1983-09-01

    We summarize the results of a seven-year research project for the US Department of Energy (DOE) to develop electric air filters that extend the service life of high-efficiency particulate air (HEPA) filters used in the nuclear industry. This project was unique to Lawrence Livermore National Laboratory (LLNL), and it entailed comprehensive theory, laboratory studies, and hardware development. We present our work in three major areas: (1) theory of and instrumentation for filter test methods, (2) theoretical and laboratory studies of electric air filters, and (3) development and evaluation of eight experimental electric air filters.

  16. Structure Change of the Insulating Composite

    Directory of Open Access Journals (Sweden)

    Vaclav Mentlik

    2008-01-01

    Full Text Available Modern power electric drives brought advantages in induction motor control. In the same time appeared problems with high frequency square waveform voltage (pulse stress produced by the voltage converters. Voltage converters produce repetitive pulses with high level of voltage rise fronts (slew rates. Rise fronts attained values of up to tens kilovolts per microsecond and voltage pulse repetition frequency up to some tens of kilohertz. This technology is an advantage for a drive control. Significant is the impact of these voltage waveforms on the motor insulations. Degradation of the main wall insulation can reduce the reliability of the electric motor and whole drive. In this paper is discussed one possible solution. The promising modification in the insulation material structure is presented in the paper.

  17. A Wind Farm Electrical Systems Evaluation with EeFarm-II

    NARCIS (Netherlands)

    Pierik, J.; Axelsson, U.; Eriksson, E.; Salomonsson, D.; Bauer, P.; Czech, B.

    2010-01-01

    EeFarm-II is used to evaluate 13 different electrical systems for a 200 MW wind farm with a 100 km connection to shore. The evaluation is based on component manufacturer data of 2009. AC systems are compared to systems with DC connections inside the wind farm and DC connection to shore. Two options

  18. Radiation degradation of plastic insulating materials

    Energy Technology Data Exchange (ETDEWEB)

    Bartonicek, B.; Hnat, V.; Janovsky, I.; Pejsa, R. [Nuclear Research Institute, Rez (Czech Republic)

    1995-10-01

    Several types of polymeric compounds, used as insulating and sheathing materials of cables, were subjected to accelerated thermal and radiation ageing and to LOCA test. The stability of materials was evaluated via their mechanical properties, namely strain at break. (Author).

  19. Evaluation of a wind turbine electric power generator

    Science.gov (United States)

    Swim, W. B.

    1981-01-01

    A technical assessment of the aerodynamic performance of the wind wheel turbine (WWT) is reported. The potential of the WWT in utilizing wind as an alternate power source was evaluated. Scaling parameters were developed to predict the aerodynamic performance of WWT prototype sized to produce 3, 9, 30, and 100 kw outputs in a 6.7 m/sec wind.

  20. Evaluation of reliability worth in an electric power system

    Energy Technology Data Exchange (ETDEWEB)

    Billinton, Roy [Saskatchewan Univ., Saskatoon, SK (Canada). Power System Research Group

    1994-12-31

    This paper illustrates the application of basic power system reliability evaluation techniques to the quantification for reliability worth. The approach presented links customer interruption cost estimates with predictable indices of power system reliability. The technique is illustrated by application in the areas of generation, composite generation and transmission, and distribution system assessment using a hypothetical test system. (author)

  1. Power Systems Evaluated for Solar Electric Propulsion Vehicles

    Science.gov (United States)

    Kerslake, Thomas W.; Gefert, Leon P.

    2000-01-01

    Solar electric propulsion (SEP) mission architectures are applicable to a wide range NASA missions including the robotic exploration of the outer planets in the next decade and the human exploration of Mars within the next 2 decades. SEP enables architectures that are very mass efficient with reasonable power levels (1-MW class) aerobrake and cryogenic upper-stage transportation technologies are utilized. In this architecture, the efficient SEP stage transfers the payload from low Earth orbit (LEO) High Energy Elliptical Parking Orbit (HEEPO) within a period of 6 to 12 months. highthrust, cryogenic upper stage and payload then separate from the SEP vehicle for injection to the planetary target, allowing for fast heliocentric trip times. This mission architecture offers a potential reduction in mass to LEO in comparison to alternative all-chemical nuclear propulsion schemes. Mass reductions may allow launch vehicle downsizing enable missions that would have been grounded because of cost constraints. The preceding figure illustrates a conceptual SEP stage design for a human Mars mission. Researchers at the NASA Glenn Research Center at Lewis Field designed conceptual SEP vehicle, conceived the mission architecture to use this vehicle, and analyzed the vehicle s performance. This SEP stage has a dry mass of 35 metric tons (MT), 40 MT of xenon propellant, and a photovoltaic array that spans 110 m, providing power to a cluster of eight 100-kW Hall thrusters. The stage can transfer an 80-MT payload and upper stage to the desired HEEPO. Preliminary packaging studies show this space-station-class SEP vehicle meets the proposed "Magnum" launch vehicle and volume requirements with considerable margin. An SEP vehicle for outer planetary missions, such as the Europa Mapper Mission, would be dramatically smaller than human Mars mission SEP stage. In this mission architecture, the SEP power system with the payload to provide spacecraft power throughout the mission. Several

  2. Electrical properties and transport mechanisms of Au/Ba0.6Sr0.4TiO3/GaN metal-insulator-semiconductor (MIS) diode at high temperature range

    Science.gov (United States)

    Rajagopal Reddy, V.

    2016-05-01

    The electrical and transport mechanisms of a fabricated Au/Ba0.6Sr0.4TiO3 (BST)/GaN metal-insulator-semiconductor (MIS) diode have been studied in the temperature range of 280-430 K by current-voltage ( I- V) and capacitance-voltage ( C- V) measurements. The barrier heights (BHs) of the Au/BST/GaN MIS diode are found to be 0.85 eV ( I- V)/1.35 ( C- V) at 280 K and 1.14 eV ( I- V)/1.17 ( C- V) at 430 K. The series resistance ( R S) values determined by Cheung's functions are in good agreement with each other. The difference between BHs estimated by I- V and C- V methods are also discussed. Results show that the estimated interface state density ( N SS) of MIS diode decreases with an increase in temperature. Observations have indicated that the BH increases whereas ideality factor R S and N SS decreases with increasing temperature. Results have demonstrated that the reverse leakage current is dominated by Poole-Frenkel emission at temperatures of 280-340 K and by Schottky emission at temperatures of 370-430 K. It is also noted that there is a transition of the conduction mechanism in Au/BST/GaN MIS diode from Poole-Frenkel to Schottky emission at temperatures of 340-370 K.

  3. Antireduction Insulator For Solid-Electrolyte Cell

    Science.gov (United States)

    Shlichta, Paul J.

    1990-01-01

    Depletion of oxygen from electrolyte prevented. Proposed to add layer of electrical insulation between solid electrolyte and portion of porous negative electrode under negative metal contact in solid-electrolyte cell. Helps maintain efficiency of cell by preventing "shadow" effect degrading portion of electrolyte under negative contact and sometimes near seals.

  4. 7 CFR 1755.890 - RUS specification for filled telephone cables with expanded insulation.

    Science.gov (United States)

    2010-01-01

    ... direct current potential between the conductors, using a light or buzzer to indicate electrical contact... conductors are solid copper, individually insulated with an extruded cellular insulating compound which may be either totally expanded or expanded with a solid skin coating. (ii) The insulated conductors are...

  5. PROBLEMS FOR DEVELOPMENT OF TECHNIQUE AND TECHNOLOGY OF COMPOSITE INSULATORS IN WESTERN EUROPE

    Directory of Open Access Journals (Sweden)

    L. Suboch

    2005-01-01

    Full Text Available Problems concerning development of composite insulators and insulator types for electric mains with a voltage higher than 1000 kV in the Western Europe are considered in the paper. It shows the prospects for obtaining a number of polymer materials (epoxy resin, silicone elastomer, ethylene-propylene rubber, polytetraftuoroethylene etc., reinforcing materials and ageing problem of polymer insulation.

  6. The efficiency of night insulation using aerogel-filled polycarbonate panels during the heating season

    Science.gov (United States)

    Adelsberger, Kathleen

    Energy is the basis for modern life. All modern technology from a simple coffee maker to massive industrial facilities is powered by energy. While the demand for energy is increasing, our planet is suffering from the consequences of using fossil fuels to generate electricity. Therefore, the world is looking at clean energy and solar power to minimize this effect on our environment. However, saving energy is extremely important even for clean energy. The more we save the less we have to generate. Heat retention in buildings is one step towards achieving passive heating. Therefore, efforts are made to prevent heat from escaping buildings through the glass during cold nights. Movable insulation is a way to increase the insulation value of the glass to reduce heat loss towards the outdoor. This thesis examines the performance of the aerogel-filled polycarbonate movable panels in the Ecohawks building, a building located on the west campus of The University of Kansas. Onsite tests were performed using air and surface temperature sensors to determine the effectiveness of the system. Computer simulations were run by Therm 7.2 simulation software to explore alternative design options. A cost analysis was also performed to evaluate the feasibility of utilizing movable insulation to reduce the heating bills during winter. Results showed that sealed movable insulation reduces heat loss through the glazing by 67.5%. Replacing aerogel with XPS panels reduces this percentage to 64.3%. However, it reduces the cost of the insulation material by 98%.

  7. Electric field analysis

    CERN Document Server

    Chakravorti, Sivaji

    2015-01-01

    This book prepares newcomers to dive into the realm of electric field analysis. The book details why one should perform electric field analysis and what are its practical implications. It emphasizes both the fundamentals and modern computational methods of electric machines. The book covers practical applications of the numerical methods in high voltage equipment, including transmission lines, power transformers, cables, and gas insulated systems.

  8. Evaluation of electricity production from alkaline pretreated sludge using two-chamber microbial fuel cell.

    Science.gov (United States)

    Xiao, Benyi; Yang, Fang; Liu, Junxin

    2013-06-15

    Electricity production from alkaline pretreated sludge was evaluated using a two-chamber microbial fuel cell (MFC). The electricity production was found to be stable over a long period of time (approximately 17 d) with voltage outputs and power densities of 0.47-0.52 V and 46.80-55.88 mW/m(2), respectively. The anode resistance was the main internal resistance (73.2%) of MFC in the stable stage. Most soluble organic matters (proteins and carbohydrates) in the anode chamber were first degraded and converted into volatile fatty acids (0-15 d), which were then degraded and converted into electricity and methane (15-29 d). The insoluble organics were solubilized thereby decreasing the sludge concentration and reducing the sludge mass. Methane was produced in the anode chamber owing to the growth of methanogens, which did not obviously affect the electricity production. The change in humic-like substances displayed a positive correlation with the electricity production of the MFC. Microbial analysis showed that methanogens and electricity-producing bacteria co-existed mostly on the surface as well as inside the anode. Decreasing the anode resistance and increasing the anode utilization could enhance the electricity production. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  9. Biomechanical Evaluation of an Electric Power-Assisted Bicycle by a Musculoskeletal Model

    Science.gov (United States)

    Takehara, Shoichiro; Murakami, Musashi; Hase, Kazunori

    In this study, we construct an evaluation system for the muscular activity of the lower limbs when a human pedals an electric power-assisted bicycle. The evaluation system is composed of an electric power-assisted bicycle, a numerical simulator and a motion capture system. The electric power-assisted bicycle in this study has a pedal with an attached force sensor. The numerical simulator for pedaling motion is a musculoskeletal model of a human. The motion capture system measures the joint angles of the lower limb. We examine the influence of the electric power-assisted force on each muscle of the human trunk and legs. First, an experiment of pedaling motion is performed. Then, the musculoskeletal model is calculated by using the experimental data. We discuss the influence on each muscle by electric power-assist. It is found that the muscular activity is decreased by the electric power-assist bicycle, and the reduction of the muscular force required for pedaling motion was quantitatively shown for every muscle.

  10. Heat Transfer through Cable Insulation of Nb–Ti Superconducting Magnets Operating in He II

    CERN Document Server

    Granieri, P P

    2013-01-01

    The operation of Nb–Ti superconducting magnets in He II relies on superfluidity to overcome the severe thermal barrier represented by the cable electrical insulation. In wrapped cable insulations, like those used for the main magnets of the Large Hadron Collider (LHC) particle accelerator, the micro-channels network created by the insulation wrappings allows to efficiently transfer the heat deposited or generated in the cable to the He bath. In this paper, available experimental data of heat transfer through polyimide electrical insulation schemes are analyzed. A steady-state thermal model is developed to describe the insulation of the LHC main dipole magnets and the Enhanced Insulation proposed for the High Luminosity LHC upgrade (HL-LHC), according to the relevant geometric parameters. The model is based on the coupled mechanisms of heat transfer through the bulk of the dielectric insulation and through micro-channels between the insulation tapes. A good agreement is found between calculations and tests p...

  11. Plasmonics in Topological Insulators

    Directory of Open Access Journals (Sweden)

    Yi-Ping Lai

    2014-04-01

    Full Text Available With strong spin-orbit coupling, topological insulators have an insulating bulk state, characterized by a band gap, and a conducting surface state, characterized by a Dirac cone. Plasmons in topological insulators show high frequency-tunability in the mid-infrared and terahertz spectral regions with transverse spin oscillations, also called “spin-plasmons”. This paper presents a discussion and review of the developments in this field from the fundamental theory of plasmons in bulk, thin-film, and surface-magnetized topological insulators to the techniques of plasmon excitation and future applications.

  12. Electrical Properties and Interfacial Studies of HfxTi1–xO2 High Permittivity Gate Insulators Deposited on Germanium Substrates

    Directory of Open Access Journals (Sweden)

    Qifeng Lu

    2015-12-01

    Full Text Available In this research, the hafnium titanate oxide thin films, TixHf1–xO2, with titanium contents of x = 0, 0.25, 0.9, and 1 were deposited on germanium substrates by atomic layer deposition (ALD at 300 °C. The approximate deposition rates of 0.2 Å and 0.17 Å per cycle were obtained for titanium oxide and hafnium oxide, respectively. X-ray Photoelectron Spectroscopy (XPS indicates the formation of GeOx and germanate at the interface. X-ray diffraction (XRD indicates that all the thin films remain amorphous for this deposition condition. The surface roughness was analyzed using an atomic force microscope (AFM for each sample. The electrical characterization shows very low hysteresis between ramp up and ramp down of the Capacitance-Voltage (CV and the curves are indicative of low trap densities. A relatively large leakage current is observed and the lowest leakage current among the four samples is about 1 mA/cm2 at a bias of 0.5 V for a Ti0.9Hf0.1O2 sample. The large leakage current is partially attributed to the deterioration of the interface between Ge and TixHf1–xO2 caused by the oxidation source from HfO2. Consideration of the energy band diagrams for the different materials systems also provides a possible explanation for the observed leakage current behavior.

  13. Surface growth of MG(multilayer graphene)-SiC nanofillers/poly(vinylidene fluoride) composites for improving thermal conductivity and maintaining electrical insulation

    Science.gov (United States)

    He, Jing; Guo, Yulan; Tian, Konghu; Wang, Hua; Su, Zheng; Huang, Weiqi; Tian, Xingyou

    2017-08-01

    In the present research, a high-frequency heating process with the advantages of simplicity and high yield was applied to synthesize multilayer graphene-SiC nanofillers (MG-SiCnf) and found to boost yields dramatically. The growth process of MG-SiCnf was also investigated. Nanofillers grown on an MG surface consisted of both SiC particles and SiC nanofibers. Interestingly, the growth process of SiC nanofibers included two main steps: firstly, SiC particles gathered on the edge of the MG, and then they grew into SiC nanofibers. SiC nanofibers enhanced the thermal conductivity of materials whereas SiC particles tended to hinder electronic transmission. The vertical and in-plane orientated thermal conductivities of poly(vinylidene fluoride) (PVDF)/MG-SiCnf composites were determined to be 0.28 and 30.491 W m-1 K-1, while the maximum value of the electrical conductivity of PVDF/MG-SiCnf composites was only 2.0  ×  10-11 S cm-1. In addition, the storage modulus of PVDF/MG-SiCnf composites also improved remarkably in comparison with that of pure PVDF.

  14. Do clinical examination gloves provide adequate electrical insulation for safe hands-on defibrillation? II: Material integrity following exposure to defibrillation waveforms.

    Science.gov (United States)

    Petley, Graham W; Deakin, Charles D

    2013-07-01

    Maintaining contact with the patient during defibrillator discharge has been proposed as a method for reducing no flow time but carries an associated risk of electrocution of the rescuer. This study describes an investigation to determine if typical clinical examination gloves possess the dielectric strength needed to prevent breakdown at defibrillation voltages; a factor essential to protect the rescuer. Four types of examination glove typically used in a clinical environment were tested with two types of defibrillation waveform commonly used. For each type of glove, 10 samples were tested initially using a monophasic defibrillation waveform and then, using a fresh sample of gloves, with a Biphasic waveform. For each glove the number of shocks required before electrical breakdown occurred was recorded. Kimberly Clark KC300 (nitrile), Kimberly Clark KC500 purple (nitrile), PH Medisavers GN90 (nitrile) and Bodyguards GL6622 (Vinyl) were tested using a monophasic defibrillation waveform and broke down after a median of 1, 4.5, 1 and 1 shocks respectively. The equivalent values for Biphasic defibrillator were 2, >10, 2.5 and 1 shocks. Typical clinical examination gloves do not possess the dielectric strength required to protect a rescuer from defibrillation voltages during hands-on chest compressions. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  15. Use of GC/MS and Microtome Techniques as Methods to Evaluate ODC Free Cleaner Diffusion and Evaporation in Insulation and Phenolic Case Material

    Science.gov (United States)

    Biegert, L. L.

    2001-01-01

    Because of the 1990 Clean Air Act Amendment (CAAA) many chlorinated solvents used in the aerospace industry are being phased out. Replacement of the ODC (ozone-depleting chemicals) with less volatile, non-ozone depleting cleaners has been extensively studied over the past seven years at Thiokol Propulsion, a Division of Cordant Technologies, Inc. The down selection of ODC replacement cleaners has been based on several factors including the diffusion evaporation of the cleaners in selected substrates. Methodologies were developed to evaluate the cleaner content in substrates. Methods of cutting thin slices of material (microtoming) were combined with GC/MS (gas chromatography/mass spectroscopy) analysis. Substrates evaluated in this study include potential solid rocket motor materials: ASNBR (asbestos-filled nitrile butadiene rubber) and CFEPDM (carbon-filled ethylene propylene dimonomer) insulation and glass (GCP), carbon (CCP) and silica (SCP) cloth phenolic substrates with fibers either parallel (0 deg) or perpendicular (90 deg) to the surface. Residue profiles indicate both cleaner and substrate composition affect the diffusion and subsequent evaporation of the cleaner from the substrate surface.

  16. The Effects of Roof and Wall Insulation on the Energy Costs of Low Income Housing in Mexico

    Directory of Open Access Journals (Sweden)

    Jorge Lucero-Álvarez

    2016-06-01

    Full Text Available Environmental conditions, such as air temperature and solar radiation, have a complex relationship with the energy requirements for heating and cooling of residential buildings. In this work, a comparative analysis of the insulation methods most commonly applied to low income single-family houses in Mexico is presented, in order to find the most energy-efficient combinations of methods for the various climates in this country. A common kind of building, small houses built with hollow cinder block walls and concrete slab roofs, was analyzed considering three insulation scenarios: walls only, roof only and both. We used dynamic simulation to evaluate energy consumption under the climate conditions found in several Mexican cities. From the energy consumption data and the cost of electricity in Mexico, we calculated net annual energy costs, including both annual energy savings and the annualized cost of the initial investment in better insulation. Results of this analysis show that insulating both roof and walls is most effective in cities with cold winters; insulating just the roof is best for temperate climates; and insulating walls (combined with high-albedo roofs is most effective for cities with year-long warm weather.

  17. Particle trap with dielectric barrier for use in gas insulated transmission lines

    Science.gov (United States)

    Dale, S.J.

    1982-06-15

    A gas-insulated transmission line includes an outer sheath, an inner conductor within the outer sheath, insulating supports supporting the inner conductor within the outer sheath, and an insulating gas electrically insulating the inner conductor from the outer sheath. An apertured particle trapping electrode is disposed within the outer sheath, and the electrode has a pair of dielectric members secured at each longitudinal end thereof, with the dielectric members extending outwardly from the apertured electrode. 7 figs.

  18. Comparative Investigation of Pollution Accumulation and Natural Cleaning for Different HV Insulators

    OpenAIRE

    Dimitropoulou, M; D. Pylarinos; K. Siderakis; Thalassinakis, E.; Danikas, M.

    2015-01-01

    High Voltage insulators are scattered throughout any HV network and a single insulator fault may cause an excessive outage. Reliability is a key issue for electric power systems and fault-free performance of insulators greatly reflects on the reliability of the system. Environmental influence is rather important for the optimum selection of outdoor insulators and, therefore, field measurements provide valuable information. Utilities perform such measurements in order to decide upon the locati...

  19. Design and Construction of a Live Insulator Washing System for Transformers

    OpenAIRE

    Lizama-Cámara Y.A.; Mendieta-Antúnez J.A.; Blanco-Brisset E.; Olivares Galván J.C.; Escarela-Pérez R.

    2012-01-01

    Through the electrical industry history there have been developments of different cleaning methods to avoid the insulators flashovers due to pollution. This paper describes the principal cleaning methods applicable to transformers insulators, emphasizing the high pressure fixed-type live insulator washing method, which was applied for cleaning the insulators of 900 MVA transformer bank of the “Laguna Verde” power plant localized at the state of Veracruz in Mexico. We propose a transformer ins...

  20. Gas insulated transmission line with insulators having field controlling recesses

    Science.gov (United States)

    Cookson, Alan H.; Pederson, Bjorn O.

    1984-01-01

    A gas insulated transmission line having a novel insulator for supporting an inner conductor concentrically within an outer sheath. The insulator has a recess contiguous with the periphery of one of the outer and inner conductors. The recess is disposed to a depth equal to an optimum gap for the dielectric insulating fluid used for the high voltage insulation or alternately disposed to a large depth so as to reduce the field at the critical conductor/insulator interface.

  1. Detection of UV Pulse from Insulators and Application in Estimating the Conditions of Insulators

    Science.gov (United States)

    Wang, Jingang; Chong, Junlong; Yang, Jie

    2014-10-01

    Solar radiation in the band of 240-280 nm is absorbed by the ozone layer in the atmosphere, and corona discharges from high-voltage apparatus emit in air mainly in the 230-405 nm range of ultraviolet (UV), so the band of 240-280 nm is called UV Solar Blind Band. When the insulators in a string deteriorate or are contaminated, the voltage distribution along the string will change, which causes the electric fields in the vicinity of insulators change and corona discharge intensifies. An UV pulse detection method to check the conditions of insulators is presented based on detecting the UV pulse among the corona discharge, then it can be confirmed that whether there exist faulty insulators and whether the surface contamination of insulators is severe for the safe operation of power systems. An UV-I Insulator Detector has been developed, and both laboratory tests and field tests have been carried out which demonstrates the practical viability of UV-I Insulator Detector for online monitoring.

  2. Silicon on insulator with active buried regions

    Science.gov (United States)

    McCarthy, Anthony M.

    1996-01-01

    A method for forming patterned buried components, such as collectors, sources and drains, in silicon-on-insulator (SOI) devices. The method is carried out by epitaxially growing a suitable sequence of single or multiple etch stop layers ending with a thin silicon layer on a silicon substrate, masking the silicon such that the desired pattern is exposed, introducing dopant and activating in the thin silicon layer to form doped regions. Then, bonding the silicon layer to an insulator substrate, and removing the silicon substrate. The method additionally involves forming electrical contact regions in the thin silicon layer for the buried collectors.

  3. Impact and Cost Evaluation of Electric Vehicle Integration on Medium Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Wu, Qiuwei; Cheng, Lin; Pineau, Ulysse

    2013-01-01

    This paper presents the analysis of the impact of electric vehicle (EV) integration on medium voltage (MV) distribution networks and the cost evaluation of replacing the overloaded grid components. A number of EV charging scenarios have been studied. A 10 kV grid from the Bornholm Island...

  4. Evaluation of Electric Vehicle Charging Controllability for Provision of Time Critical Grid Services

    DEFF Research Database (Denmark)

    Martinenas, Sergejus; Marinelli, Mattia; Andersen, Peter Bach

    2016-01-01

    of electric vehicles. EVs are a fast responding energy resource with high availability. This work evaluates and experimentally shows the limits of EV charging controllability with the focus on its suitability for providing ancillary grid services. Three different series produced EVs are tested...

  5. Applying of Electrical Imaging Survey (EIS) to Evaluate Leachate Pollution in Underground Area of Informal Landfill

    DEFF Research Database (Denmark)

    Du, Song; Wang, Di; Mou, Zishen

    2014-01-01

    An informal landfill is an open dump that pollutes the underground environment because it lacks an impervious liner. The leakage of such a landfill is unidirectional and thus difficult to directly test. This study uses electrical imaging survey to evaluate the pollution of the underground...

  6. Evaluating piezo-electric transducer response to thermal shock from in-cylinder pressure data

    NARCIS (Netherlands)

    Rosseel, E.; Sierens, R.; Baert, R.S.G.

    1999-01-01

    One of the major effects limiting the accuracy of piezo-electric transducers for performing in-cyclinder pressure measurements is their sensitivity to the cyclic thermal loading effects of the intermittent combustion process. This paper compares 5 different methods for evaluating the effect of this

  7. Translucent insulating building envelope

    DEFF Research Database (Denmark)

    Rahbek, Jens Eg

    1997-01-01

    A new type of translucent insulating material has been tested. This material is made of Celulose-Acetat and have a honey-comb structure. The material has a high solar transmittance and is highly insulating. The material is relatively cheap to produce. Danish Title: Translucent isolerende klimaskærm....

  8. Measurement and Evaluation of Heating Performance of Heat Pump Systems Using Wasted Heat from Electric Devices for an Electric Bus

    OpenAIRE

    Cho, Chung-Won; Lee, Ho-Seong; Won, Jong-Phil; Lee, Moo-Yeon

    2012-01-01

    The objective of this study is to investigate heating performance characteristics of a coolant source heat pump using the wasted heat from electric devices for an electric bus. The heat pump, using R-134a, is designed for heating a passengers’ compartment by using discharged energy from the coolant of electric devices, such as motors and inverters of the electric bus. The heating performance of the heat pump was tested by varying the operating parameters, such as outdoor temperature and volum...

  9. Electrical characterization of conductive textile materials and its evaluation as electrodes for venous occlusion plethysmography.

    Science.gov (United States)

    Goy, C B; Dominguez, J M; Gómez López, M A; Madrid, R E; Herrera, M C

    2013-08-01

    The ambulatory monitoring of biosignals involves the use of sensors, electrodes, actuators, processing tools and wireless communication modules. When a garment includes these elements with the purpose of recording vital signs and responding to specific situations it is call a 'Smart Wearable System'. Over the last years several authors have suggested that conductive textile material (e-textiles) could perform as electrode for these systems. This work aims at implementing an electrical characterization of e-textiles and an evaluation of their ability to act as textile electrodes for lower extremity venous occlusion plethysmography (LEVOP). The e-textile electrical characterization is carried out using two experimental set-ups (in vitro evaluation). Besides, LEVOP records are obtained from healthy volunteers (in vivo evaluation). Standard Ag/AgCl electrodes are used for comparison in all tests. Results shown that the proposed e-textiles are suitable for LEVOP recording and a good agreement between evaluations (in vivo and in vitro) is found.

  10. Sound insulation between dwellings

    DEFF Research Database (Denmark)

    Rasmussen, Birgit

    2011-01-01

    Regulatory sound insulation requirements for dwellings exist in more than 30 countries in Europe. In some countries, requirements have existed since the 1950s. Findings from comparative studies show that sound insulation descriptors and requirements represent a high degree of diversity...... and initiate – where needed – improvement of sound insulation of new and existing dwellings in Europe to the benefit of the inhabitants and the society. A European COST Action TU0901 "Integrating and Harmonizing Sound Insulation Aspects in Sustainable Urban Housing Constructions", has been established and runs...... 2009-2013. The main objectives of TU0901 are to prepare proposals for harmonized sound insulation descriptors and for a European sound classification scheme with a number of quality classes for dwellings. Findings from the studies provide input for the discussions in COST TU0901. Data collected from 24...

  11. Sound Insulation between Dwellings

    DEFF Research Database (Denmark)

    Rasmussen, Birgit

    2011-01-01

    Regulatory sound insulation requirements for dwellings exist in more than 30 countries in Europe. In some countries, requirements have existed since the 1950s. Findings from comparative studies show that sound insulation descriptors and requirements represent a high degree of diversity...... and initiate – where needed – improvement of sound insulation of new and existing dwellings in Europe to the benefit of the inhabitants and the society. A European COST Action TU0901 "Integrating and Harmonizing Sound Insulation Aspects in Sustainable Urban Housing Constructions", has been established and runs...... 2009-2013. The main objectives of TU0901 are to prepare proposals for harmonized sound insulation descriptors and for a European sound classification scheme with a number of quality classes for dwellings. Findings from the studies provide input for the discussions in COST TU0901. Data collected from 24...

  12. Electrical and carrier transport properties of the Au/Y2O3/n-GaN metal-insulator-semiconductor (MIS) diode with rare-earth oxide interlayer

    Science.gov (United States)

    Venkata Prasad, C.; Rajagopal Reddy, V.; Choi, Chel-Jong

    2017-04-01

    The electrical and transport properties of rare-earth Y2O3 on n-type GaN with Au electrode have been investigated by current-voltage and capacitance-voltage techniques at room temperature. The Au/Y2O3/n-GaN metal-insulator-semiconductor (MIS) diode shows a good rectification behavior compared to the Au/n-GaN metal-semiconductor (MS) diode. Statistical analysis showed that a mean barrier height (BH) and ideality factor are 0.78 eV and 1.93, and 0.96 eV and 2.09 for the Au/n-GaN MS and Au/Y2O3/n-GaN MIS diodes, respectively. Results indicate that the high BH is obtained for the MIS diode compared to the MS diode. The BH, ideality factor and series resistance are also estimated by Cheung's function and Norde method. From the forward current-voltage data, the interface state density ( N SS) is estimated for both the MS and MIS Schottky diodes, and found that the estimated N SS is lower for the MIS diode compared to the MS diode. The results reveal that the introduction of Y2O3 interlayer facilitated the reduction of N SS of the Au/n-GaN interface. Experimental results suggest that the Poole-Frenkel emission is a dominant conduction mechanism in the reverse bias region of both Au/n-GaN MS and Au/Y2O3/n-GaN MIS diodes.

  13. Evaluation and Ranking of Geothermal Resources for Electrical Generation or Electrical Offset in Idaho, Montana, Oregon and Washington. Volume II.

    Energy Technology Data Exchange (ETDEWEB)

    Bloomquist, R. Gordon

    1985-06-01

    This volume contains appendices on: (1) resource assessment - electrical generation computer results; (2) resource assessment summary - direct use computer results; (3) electrical generation (high temperature) resource assessment computer program listing; (4) direct utilization (low temperature) resource assessment computer program listing; (5) electrical generation computer program CENTPLANT and related documentation; (6) electrical generation computer program WELLHEAD and related documentation; (7) direct utilization computer program HEATPLAN and related documentation; (8) electrical generation ranking computer program GEORANK and related documentation; (9) direct utilization ranking computer program GEORANK and related documentation; and (10) life cycle cost analysis computer program and related documentation. (ACR)

  14. Evaluation testing of a closed Brayton-cycle electrical-power-conversion system.

    Science.gov (United States)

    Redding, T. E.; Mcgee, J. M.; Luksa, N. C.

    1972-01-01

    Description of the design and testing of a recuperated, closed Brayton-cycle, electrical power conversion system designated the Brayton Cycle Demonstrator (BCD). The system uses electrical heaters as a heat source, argon as the cycle working fluid, and gas-lubricated foil-type bearings. Objectives of the test program include (1) evaluation of the overall system performance characteristics and influences on spacecraft integration, (2) familiarization of personnel with operational methods, and (3) determination of system flexibility by operating at a number of off-design conditions. Results obtained to date are discussed.

  15. Evaluation of an Early Three Phase Approach to Electric Circuit Instruction

    Directory of Open Access Journals (Sweden)

    Matthew Turner

    2017-02-01

    Full Text Available This paper presents a novel approach to the study of electric circuits: utilizing three phase electric power systems to introduce students to the techniques of circuit analysis beyond Kirchhoff’s and Ohm’s Laws. The efficacy of the pedagogy is evaluated by comparison of student performance on DC circuits assessment quiz pre and post intervention and by comparison to circuit analysis methods used by experts. Also discusses is how the curriculum effects students qualitative and quantitative conceptions of the behavior of voltage and current in DC resistive circuits.

  16. Evaluation of atmospheric corrosion on electroplated zinc and zinc nickel coatings by Electrical Resistance (ER) Monitoring

    DEFF Research Database (Denmark)

    Møller, Per

    2013-01-01

    ER (Electrical Resistance) probes provide a measurement of metal loss, measured at any time when a metal is exposed to the real environment. The precise electrical resistance monitoring system can evaluate the corrosion to the level of nanometers, if the conductivity is compensated for temperature...... and magnetic fields. With this technique very important information about the durability of a new conversion coatings for aluminum, zinc and zinc alloys exposed to unknown atmospheric conditions can be gathered. This is expected to have a major impact on a number of industrial segments, such as test cars...

  17. Flux pumping for non-insulated and metal-insulated HTS coils

    Science.gov (United States)

    Ma, Jun; Geng, Jianzhao; Coombs, T. A.

    2018-01-01

    High-temperature superconducting (HTS) coils wound from coated conductors without turn-to-turn insulation (non-insulated (NI) coils) have been proven with excellent electrical and thermal performances. However, the slow charging of NI coils has been a long-lasting problem. In this work, we explore using a transformer-rectifier HTS flux pump to charge an NI coil and a metal-insulated coil. The charging performance comparison is made between different coils. Comprehensive study is done to thoroughly understand the electrical-magnetic transience in charging these coils. We will show that the low-voltage high-current flux pump is especially suitable for charging NI coils with very low characteristic resistance.

  18. Topological Field Theory of Time-Reversal Invariant Insulators

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Xiao-Liang; Hughes, Taylor; Zhang, Shou-Cheng; /Stanford U., Phys. Dept.

    2010-03-19

    We show that the fundamental time reversal invariant (TRI) insulator exists in 4 + 1 dimensions, where the effective field theory is described by the 4 + 1 dimensional Chern-Simons theory and the topological properties of the electronic structure is classified by the second Chern number. These topological properties are the natural generalizations of the time reversal breaking (TRB) quantum Hall insulator in 2 + 1 dimensions. The TRI quantum spin Hall insulator in 2 + 1 dimensions and the topological insulator in 3 + 1 dimension can be obtained as descendants from the fundamental TRI insulator in 4 + 1 dimensions through a dimensional reduction procedure. The effective topological field theory, and the Z{sub 2} topological classification for the TRI insulators in 2+1 and 3+1 dimensions are naturally obtained from this procedure. All physically measurable topological response functions of the TRI insulators are completely described by the effective topological field theory. Our effective topological field theory predicts a number of novel and measurable phenomena, the most striking of which is the topological magneto-electric effect, where an electric field generates a magnetic field in the same direction, with an universal constant of proportionality quantized in odd multiples of the fine structure constant {alpha} = e{sup 2}/hc. Finally, we present a general classification of all topological insulators in various dimensions, and describe them in terms of a unified topological Chern-Simons field theory in phase space.

  19. An Education in Electrical Safety.

    Science.gov (United States)

    McBride, John W.; Chiappetta, Eugene L.

    1992-01-01

    Discusses teaching electrical safety guidelines in the process of teaching the concepts related to electricity. Discusses household current; electrical insulation; and examples of electrical safety in the home related to appliances, the bathroom, the yard and the neighborhood. (10 references) (MDH)

  20. Study on Insulating Material by Renewable Resources

    Science.gov (United States)

    Kurata, Yasuyuki; Kurosumi, Akihiro; Ishikawa, Keita

    Under circumstances such as global warming caused by carbon dioxide and other green house gas and crisis of depletion of fossil resources, recyclable resources such as biomass have captured the world's attention as reproducible resources alternative to petroleum. Therefore the technologies such to manufacture chemicals from recyclable resources have been developed for the achievement of measures for controlling global warming and the low carbon society. Recently, the bioplastic such as polylactic resin is applied to the home appliances and the automobile interior part as substitution of general-purpose plastic Moreover, the insulation oil from the vegetable oil has been put to practical use. The application of recyclable resources is extending in an electric field. In this paper, we introduce the characteristic and the problem of the insulating material made from recyclable resources in the field of the solid insulation.

  1. Optimisation of Multilayer Insulation an Engineering Approach

    CERN Document Server

    Chorowski, M; Parente, C; Riddone, G

    2001-01-01

    A mathematical model has been developed to describe the heat flux through multilayer insulation (MLI). The total heat flux between the layers is the result of three distinct heat transfer modes: radiation, residual gas conduction and solid spacer conduction. The model describes the MLI behaviour considering a layer-to-layer approach and is based on an electrical analogy, in which the three heat transfer modes are treated as parallel thermal impedances. The values of each of the transfer mode vary from layer to layer, although the total heat flux remains constant across the whole MLI blanket. The model enables the optimisation of the insulation with regard to different MLI parameters, such as residual gas pressure, number of layers and boundary temperatures. The model has been tested with experimental measurements carried out at CERN and the results revealed to be in a good agreement, especially for insulation vacuum between 10-5 Pa and 10-3 Pa.

  2. Fast Charge Battery Electric Transit Bus In-Use Fleet Evaluation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Prohaska, Robert; Eudy, Leslie; Kelly, Kenneth

    2016-05-06

    The focus of this interim fleet evaluation is to characterize and evaluate the operating behavior of Foothill Transit's fast charge battery electric buses (BEBs). Future research will compare the BEBs' performance to conventional vehicles. In an effort to better understand the impacts of drive cycle characteristics on advanced vehicle technologies, researchers at the National Renewable Energy Laboratory analyzed over 148,000 km of in-use operational data, including driving and charging events. This analysis provides an unbiased evaluation of advanced vehicle technologies in real-world operation demonstrating the importance of understanding the effects of road grade and heating, ventilating and air conditioning requirements when deploying electric vehicles. The results of this analysis show that the Proterra BE35 demonstrated an operating energy efficiency of 1.34 kWh/km over the data reporting period.

  3. Bulk electric system reliability evaluation incorporating wind power and demand side management

    Science.gov (United States)

    Huang, Dange

    Electric power systems are experiencing dramatic changes with respect to structure, operation and regulation and are facing increasing pressure due to environmental and societal constraints. Bulk electric system reliability is an important consideration in power system planning, design and operation particularly in the new competitive environment. A wide range of methods have been developed to perform bulk electric system reliability evaluation. Theoretically, sequential Monte Carlo simulation can include all aspects and contingencies in a power system and can be used to produce an informative set of reliability indices. It has become a practical and viable tool for large system reliability assessment technique due to the development of computing power and is used in the studies described in this thesis. The well-being approach used in this research provides the opportunity to integrate an accepted deterministic criterion into a probabilistic framework. This research work includes the investigation of important factors that impact bulk electric system adequacy evaluation and security constrained adequacy assessment using the well-being analysis framework. Load forecast uncertainty is an important consideration in an electrical power system. This research includes load forecast uncertainty considerations in bulk electric system reliability assessment and the effects on system, load point and well-being indices and reliability index probability distributions are examined. There has been increasing worldwide interest in the utilization of wind power as a renewable energy source over the last two decades due to enhanced public awareness of the environment. Increasing penetration of wind power has significant impacts on power system reliability, and security analyses become more uncertain due to the unpredictable nature of wind power. The effects of wind power additions in generating and bulk electric system reliability assessment considering site wind speed

  4. Effects of Silver Microparticles and Nanoparticles on Thermal and Electrical Characteristics of Electrically Conductive Adhesives

    Science.gov (United States)

    Zulkarnain, M.; Fadzil, M. A.; Mariatti, M.; Azid, I. A.

    2017-11-01

    The effects of different volume fractions of silver (Ag) particles of different size (microsize, 2 μm to 3.5 μm diameter; nanosize, 80 nm diameter) on the thermal and electrical characteristics of epoxy-Ag electrically conductive adhesive (ECA) have been evaluated, as well as hybrid ECAs with both particle sizes at different ratios. Improved thermal and electrical conductivity resulted from the interaction between the particles, as evaluated by analysis of sample morphology. The interaction was altered to improve the conductivity. For both particle sizes, the electrical resistivity showed a transition from insulation to conduction at 6 vol.% Ag. In the hybrid system, the thermal conductivity decreased with increasing microparticle filler ratio. The electrical conductivity of the hybrid composite increased at 50:50 weight ratio.

  5. Efficiency evaluation of gas fuelled and electric driven buses in the public transport sector

    Energy Technology Data Exchange (ETDEWEB)

    Aigner, Tobias Alexander

    2013-07-01

    The following report evaluates the efficiency of gas fuelled and electric driven buses in the public transport sector on a theoretical basis. The results indicate that the combination of CHP power plants and electric driven buses reach an overall efficiency of about 51% throughout the production chain (Well-to-Wheel), including heat distribution losses. The overall Well-to-Wheel efficiency for conventional gas turbines without heat recovery decreases to around 28%. For gas fuelled buses the Well-to-Wheel efficiency is about 30%. The Co2-emissions are evaluated based on the example of a #Left Double Quotation Mark#Volvo B10L CNG#Right Double Quotation Mark# gas bus and the electric driven #Left Double Quotation Mark#Eurabus 600#Right Double Quotation Mark#. The low energy consumption of the electric driven bus results in Co2-emissions of only 181.4 g Co2/km (Grid-to-Wheel). Depending on the utilised power plant technology the overall Co2-emissions (Well-to-Wheel) amount to 307.5 g Co2/km for a CHP power plant and 553.5 g Co2/km for a conventional gas turbine. On the other hand, gas fuelled buses emit about 1.25 kg Co2/km (Tank-to-Wheel), which is eightfold the emissions of an electrical bus. The Well-to-Tank emissions further increase to about 1.32 kg Co2/km. The emission calculation is based on real gas consumption data from a Norwegian public transport utility. The results indicate that the combination of CHP plants and electrical buses provide a much higher efficiency while reducing Co2-emissions. (author)

  6. Via sidewall insulation for through cell via contacts

    Science.gov (United States)

    de Lafontaine, Mathieu; Jaouad, Abdelatif; Darnon, Maxime; Volatier, Maïté; Arès, Richard; Fafard, Simon; Aimez, Vincent

    2017-09-01

    Over the past few years, through cell via contacts (TCVC) architecture has been the object of a growing interest to replace standard front side and backside contact on concentrated photovoltaic (CPV) cells. The technology is based on transferring the front side contact to the backside using insulated and metallized vias. This architecture could reduce shading and series resistance, thus increasing device efficiency. However, the processes involved in TCVC fabrication increases the risk of creating short-circuit, reducing significantly the efficiency of the solar cell. Therefore, the electrical insulation must be defect free. In this paper, an insulation validation protocol is proposed in order to thoroughly study the insulation quality. This process has been used to compare two insulation deposition techniques candidates: plasma-enhanced chemical vapor deposition (PECVD) and plasma-enhanced atomic layer deposition (PEALD). Results show that the insulation validation protocol presents several strengths such as revealing defects otherwise unobservable even with scanning electron microscopy. PECVD insulation presents several insulation defects whereas PEALD presents almost no defects making it suited for via insulation.

  7. Common test methods for insulating and sheathing materials of electric cables part 1-1: methods for general application : measurement of thickness and overall dimensions : tests for determining the mechanical properties

    CERN Document Server

    International Electrotechnical Commission. Geneva

    2001-01-01

    Gives the methods for measuring thicknesses and overall dimensions, and for determining the mechanical properties, which apply to the most common types of insulating and sheathing compounds (elastometic, PVC, PE, PP, etc.).

  8. Electrical installations technology

    CERN Document Server

    Whitfield, J F

    1968-01-01

    Electrical Installations Technology covers the syllabus of the City and Guilds of London Institute course No. 51, the "Electricians B Certificate”. This book is composed of 15 chapters that deal with basic electrical science and electrical installations. The introductory chapters discuss the fundamentals and basic electrical principles, including the concept of mechanics, heat, magnetic fields, electric currents, power, and energy. These chapters also explore the atomic theory of electric current and the electric circuit, conductors, and insulators. The subsequent chapter focuses on the chemis

  9. Gas insulated substations

    CERN Document Server

    2014-01-01

    This book provides an overview on the particular development steps of gas insulated high-voltage switchgear, and is based on the information given with the editor's tutorial. The theory is kept low only as much as it is needed to understand gas insulated technology, with the main focus of the book being on delivering practical application knowledge. It discusses some introductory and advanced aspects in the meaning of applications. The start of the book presents the theory of Gas Insulated Technology, and outlines reliability, design, safety, grounding and bonding, and factors for choosing GIS. The third chapter presents the technology, covering the following in detail: manufacturing, specification, instrument transformers, Gas Insulated Bus, and the assembly process. Next, the book goes into control and monitoring, which covers local control cabinet, bay controller, control schemes, and digital communication. Testing is explained in the middle of the book before installation and energization. Importantly, ...

  10. A magnetic heterostructure of topological insulators as a candidate for an axion insulator.

    Science.gov (United States)

    Mogi, M; Kawamura, M; Yoshimi, R; Tsukazaki, A; Kozuka, Y; Shirakawa, N; Takahashi, K S; Kawasaki, M; Tokura, Y

    2017-05-01

    The axion insulator which may exhibit an exotic quantized magnetoelectric effect is one of the most interesting quantum phases predicted for the three-dimensional topological insulator (TI). The axion insulator state is expected to show up in magnetically doped TIs with magnetizations pointing inwards and outwards from the respective surfaces. Towards the realization of the axion insulator, we here engineered a TI heterostructure in which magnetic ions (Cr) are modulation-doped only in the vicinity of the top and bottom surfaces of the TI ((Bi,Sb)2Te3) film. A separation layer between the two magnetic layers weakens interlayer coupling between them, enabling the magnetization reversal of individual layers. We demonstrate the realization of the axion insulator by observing a zero Hall plateau (ZHP) (where both the Hall and longitudinal conductivity become zero) in the electric transport properties, excluding the other possible origins for the ZHP. The manifestation of the axion insulator can lead to a new stage of research on novel magnetoelectric responses in topological matter.

  11. Multifactor Stress Aging of Electrical Insulation

    Science.gov (United States)

    1990-11-29

    spaciai A- ---I--C alI RESEARCH OBJECTIVES To establish a physical and experimental base in order to study and understand multifactor stress (radiation...for their support and also to Maxwell Laboratories for winding the capacitors for this project. REFERENCES 1. J.R. Laghad and A. Hammoud , "A Brief...the Crystalline Content of Irradiated Linear Polyethylene Upon Ageing," Polymer, Vol. 23, pp.654-655, 1982. 17. A. N. Hammoud , J. R. Laghari and B

  12. Pure spin current devices based on ferromagnetic topological insulators

    Science.gov (United States)

    Götte, Matthias; Joppe, Michael; Dahm, Thomas

    2016-01-01

    Two-dimensional topological insulators possess two counter propagating edge channels with opposite spin direction. Recent experimental progress allowed to create ferromagnetic topological insulators realizing a quantum anomalous Hall (QAH) state. In the QAH state one of the two edge channels disappears due to the strong ferromagnetic exchange field. We investigate heterostructures of topological insulators and ferromagnetic topological insulators by means of numerical transport calculations. We show that spin current flow in such heterostructures can be controlled with high fidelity. Specifically, we propose spintronic devices that are capable of creating, switching and detecting pure spin currents using the same technology. In these devices electrical currents are directly converted into spin currents, allowing a high conversion efficiency. Energy independent transport properties in combination with large bulk gaps in some topological insulator materials may allow operation even at room temperature. PMID:27782187

  13. Degree of Fault Tolerance as a Comprehensive Parameter for Reliability Evaluation of Fault Tolerant Electric Traction Drives

    Directory of Open Access Journals (Sweden)

    Igor Bolvashenkov

    2016-09-01

    Full Text Available This paper describes a new approach and methodology of quantitative assessment of the fault tolerance of electric power drive consisting of the multi-phase traction electric motor and multilevel electric inverter. It is suggested to consider such traction drive as a system with several degraded states. As a comprehensive parameter for evaluating of the fault tolerance, it is proposed to use the criterion of degree of the fault tolerance. For the approbation of the proposed method, the authors carried out research and obtained results of its practical application for evaluating the fault tolerance of the power train of an electrical helicopter.

  14. INTEGRAL INDEX OF OPERATION QUALITY FOR EVALUATION OF IMPACT OF DISTRIBUTIVE GENERATION SOURCES ON ELECTRIC NETWORK MODES

    Directory of Open Access Journals (Sweden)

    Petro D. Lezhniuk

    2017-06-01

    Full Text Available Method of operation quality evaluation of electric network, comprising renewable sources of energy (RSE is considered. Integral index that enables to evaluate the impact of RSE on energy losses and its quality as well as balance reliability in electric network is suggested. Mathematical model is constructed, taking into account the assumption that electric network with RSE may be in various operation modes, characterized by different technical economic indices. To determine the integral index of operation quality of electric network with RSE in all possible states tools of Markov processes theory and criterial method are used.

  15. Detection and emotional evaluation of an electric vehicle’s exterior sound in a simulated environment

    OpenAIRE

    Singh, Sneha; Payne, Sarah R.; Jennings, P.A.

    2013-01-01

    Electric vehicles are quiet at low speeds and thus potentially pose a threat to pedestrians’ safety. Laws are formulating worldwide that mandate these vehicles emit sounds to alert the pedestrians of the vehicles’ approach. It is necessary that these sounds promote a positive perception of the vehicle brand, and understanding their impact on soundscapes is also important. Detection time of the vehicle sounds is an important measure to assess pedestrians’ safety. Emotional evaluation of these ...

  16. Evaluation of Constant Potential Method in Simulating Electric Double-Layer Capacitors

    OpenAIRE

    Wang, Zhenxing; Yang, Yang; Olmsted, David L.; Asta, Mark; Laird, Brian B.

    2014-01-01

    A major challenge in the molecular simulation of electric double layer capacitors (EDLCs) is the choice of an appropriate model for the electrode. Typically, in such simulations the electrode surface is modeled using a uniform fixed charge on each of the electrode atoms, which ignores the electrode response to local charge fluctuations induced by charge fluctuations in the electrolyte. In this work, we evaluate and compare this Fixed Charge Method (FCM) with the more realistic Constant Potent...

  17. Perioperative thermal insulation.

    Science.gov (United States)

    Bräuer, Anselm; Perl, Thorsten; English, Michael J M; Quintel, Michael

    2007-01-01

    Perioperative hypothermia remains a common problem during anesthesia and surgery. Unfortunately, the implementation of new minimally invasive surgical procedures has not lead to a reduction of this problem. Heat losses from the skin can be reduced by thermal insulation to avoid perioperative hypothermia. However, only a small amount of information is available regarding the physical properties of insulating materials used in the Operating Room (OR). Therefore, several materials using validated manikins were tested. Heat loss from the surface of the manikin can be described as:"Q = h . DeltaT . A" where Q = heat flux, h = heat exchange coefficient, DeltaT = temperature gradient between the environment and surface, and A = covered area. Heat flux per unit area and surface temperature were measured with calibrated heat flux transducers. Environmental temperature was measured using a thermoanemometer. The temperature gradient between the surface and environment (DeltaT) was varied and "h" was determined by linear regression analysis as the slope of "DeltaT" versus heat flux per unit area. The reciprocal of the heat exchange coefficient defines the insulation. The insulation values of the materials varied between 0.01 Clo (plastic bag) to 2.79 Clo (2 layers of a hospital duvet). Given the range of insulating materials available for outdoor activities, significant improvement in insulation of patients in the OR is both possible and desirable.

  18. Evaluation of the Life Cycle Greenhouse Gas Emissions from Different Biomass Feedstock Electricity Generation Systems

    Directory of Open Access Journals (Sweden)

    Akhil Kadiyala

    2016-11-01

    Full Text Available This paper evaluates life cycle greenhouse gas (GHG emissions from the use of different biomass feedstock categories (agriculture residues, dedicated energy crops, forestry, industry, parks and gardens, wastes independently on biomass-only (biomass as a standalone fuel and cofiring (biomass used in combination with coal electricity generation systems. The statistical evaluation of the life cycle GHG emissions (expressed in grams of carbon dioxide equivalent per kilowatt hour, gCO2e/kWh for biomass electricity generation systems was based on the review of 19 life cycle assessment studies (representing 66 biomass cases. The mean life cycle GHG emissions resulting from the use of agriculture residues (N = 4, dedicated energy crops (N = 19, forestry (N = 6, industry (N = 4, and wastes (N = 2 in biomass-only electricity generation systems are 291.25 gCO2e/kWh, 208.41 gCO2e/kWh, 43 gCO2e/kWh, 45.93 gCO2e/kWh, and 1731.36 gCO2e/kWh, respectively. The mean life cycle GHG emissions for cofiring electricity generation systems using agriculture residues (N = 10, dedicated energy crops (N = 9, forestry (N = 9, industry (N = 2, and parks and gardens (N = 1 are 1039.92 gCO2e/kWh, 1001.38 gCO2e/kWh, 961.45 gCO2e/kWh, 926.1 gCO2e/kWh, and 1065.92 gCO2e/kWh, respectively. Forestry and industry (avoiding the impacts of biomass production and emissions from waste management contribute the least amount of GHGs, irrespective of the biomass electricity generation system.

  19. Bi-Level Optimization for Available Transfer Capability Evaluation in Deregulated Electricity Market

    Directory of Open Access Journals (Sweden)

    Beibei Wang

    2015-11-01

    Full Text Available Available transfer capability (ATC is the transfer capability remaining in the physical transmission network for further commercial activity over and above already committed uses which needs to be posted in the electricity market to facilitate competition. ATC evaluation is a complicated task including the determination of total transfer capability (TTC and existing transfer capability (ETC. In the deregulated electricity market, ETC is decided by the independent system operator’s (ISO’s economic dispatch (ED. TTC can then be obtained by a continuation power flow (CPF method or by an optimal power flow (OPF method, based on the given ED solutions as well as the ETC. In this paper, a bi-level optimization framework for the ATC evaluation is proposed in which ATC results can be obtained simultaneously with the ED and ETC results in the deregulated electricity market. In this bi-level optimization model, ATC evaluation is formulated as the upper level problem and the ISO’s ED is the lower level problem. The bi-level model is first converted to a mathematic program with equilibrium constraints (MPEC by recasting the lower level problem as its Karush-Kuhn-Tucher (KKT optimality condition. Then, the MPEC is transformed into a mixed-integer linear programming (MILP problem, which can be solved with the help of available optimization software. In addition, case studies on PJM 5-bus, IEEE 30-bus, and IEEE 118-bus systems are presented to demonstrate the proposed methodology.

  20. Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators.

    Science.gov (United States)

    Kim, Pil-Jong; Kim, Hong-Gee; Cho, Byeong-Hoon

    2015-05-01

    The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL). The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC) in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

  1. The fuzzy comprehensive evaluation on occupational health hazards of electric field in substation

    Science.gov (United States)

    Zhao, Xin; Wang, Jing; Gao, Yang; Chen, Tao

    2017-05-01

    In this paper, multilevel fuzzy analysis method is used to making a comprehensive evaluation on the health hazards of workers exposed to electric field in 500kV substation. The five different regions of 500kV substation is identified as the first level index, according to the specific measurement substation of each area to set up the second level index. The first level weight is established according to the proportion of the retention time of the workers in the different areas, and the weight of the second level is determined according to the proportion of the measuring points. Establishing five comment sets, and carrying out the fuzzy comprehensive evaluation according to the maximum membership principle, eventually come to the conclusion: although the measured data show that a small number of electric field intensity exposure value of 500kV substation beyond the requirements of the International Commission on non-ionizing radiation protection (ICNIRP) and the requirements of the People's Republic of China(PRC), but workers have very little contact time, therefore, it cannot be explained that there is a large occupational health hazard in 500kV substation. The multilevel fuzzy analysis method can be used to evaluate the health hazards of the electric field in the substation working environment well, it avoids the subjective and limitations of the traditional methods, and can be able to make a more accurate and objective judgment of the substation

  2. Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators

    Directory of Open Access Journals (Sweden)

    Pil-Jong Kim

    2015-05-01

    Full Text Available Objectives The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL. Materials and Methods The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Results Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Conclusions Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

  3. Composite aerogel insulation for cryogenic liquid storage

    Science.gov (United States)

    Kyeongho, Kim; Hyungmook, Kang; Soojin, Shin; In Hwan, Oh; Changhee, Son; Hyung, Cho Yun; Yongchan, Kim; Sarng Woo, Karng

    2017-02-01

    High porosity materials such as aerogel known as a good insulator in a vacuum range (10-3 ∼ 1 Torr) was widely used to storage and to transport cryogenic fluids. It is necessary to be investigated the performance of aerogel insulations for cryogenic liquid storage in soft vacuum range to atmospheric pressure. A one-dimensional insulating experimental apparatus was designed and fabricated to consist of a cold mass tank, a heat absorber and an annular vacuum space with 5-layer (each 10 mm thickness) of the aerogel insulation materials. Aerogel blanket for cryogenic (used maximum temperature is 400K), aerogel blanket for normal temperature (used maximum temperature is 923K), and combination of the two kinds of aerogel blankets were 5-layer laminated between the cryogenic liquid wall and the ambient wall in vacuum space. Also, 1-D effective thermal conductivities of the insulation materials were evaluated by measuring boil-off rate from liquid nitrogen and liquid argon. In this study, the effective thermal conductivities and the temperature-thickness profiles of the two kinds of insulators and the layered combination of the two different aerogel blankets were presented.

  4. Review of nuclear electricity generation and desalination plants and evaluation of SMART application

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Han Ok; Kang, Hyung Suk; Cho, Bong Hyun; Yoon, Ju Hyeon; Kim, Hwan Yeol; Lee, Young Jin; Kim, Joo Pyung; Lee, Doo Jeong; Chang, Moon Hee

    1998-03-01

    KAERI are developing a new advanced integral reactor named SMART for dual application purpose of the electric power generation and seawater desalination. This report are describing the general desalting methods with its technology development and the coupling schemes between electricity generation system and desalting system. Though MSF takes the most part of currently operating seawater desalination plants, MED and RO has been preferred in the past decade. MED has a advantage over MSF with the view to investment costs and energy efficiency. The coupling between electricity generation system and desalination system can be realized by using one of back pressure cycle, extraction cycle, and multi-shaft cycle. New design and operating strategy has to be established for various environment and load conditions. To evaluate the candidate desalination systems of SMART and the coupling method of it with other secondary systems, the desalted water and electricity were calculated through the several options. The result shows that back pressure cycle is preferred at the high water/power ratio and extraction cycle at the low value. If energy efficiency are only considered, RO will be best choice. (author). 17 refs., 12 tabs., 31 figs

  5. Evaluation of Freshness of Soft Tissue Samples with Optical Coherence Tomography Assisted by Low Frequency Electric Field

    OpenAIRE

    A. Pena; A. Sadovoy; A. Doronin; A. Bykov; I. Meglinski

    2015-01-01

    We present an optical coherence tomography based methodology to determine freshness of soft tissue samples by evaluation of their interaction with low frequency electric field. Various biological tissues samples of different stages of freshness were exposed by low frequency electric current. The influence of the low frequency electric field on tissues was observed and quantified by the double correlation optical coherence tomography (dcOCT) approach developed in house. The quantitative evalua...

  6. Pilot project for evaluating motorized personal transportation devices : Segways and electric scooters

    Energy Technology Data Exchange (ETDEWEB)

    Lavallee, P. [Centre for Electric Vehicle Experimentation in Quebec, Saint-Jerome, PQ (Canada)

    2004-05-01

    This report presented information on the Segway and electric scooter, 2 types of motorized personal transportation devices (MPTDs) that are the subject of a 2-phase pilot project conducted by the Centre for Electric Vehicle Experimentation. A general literature review of MPTDs was presented, with a focus on pilot projects carried out in the United States and Europe, along with legislation in various countries regarding user safety, legal frameworks, and traffic conditions. The report also contained an analysis of existing safety regulations for Segways and scooters, the legal framework for using the vehicles, as well as information concerning traffic rules and incidents involving MPTDs in Canada. In addition, details of a group of tests conducted by groups of experts and a group of 50 participants were presented. Various ergonomic, technical and operational evaluations of the MPTDs were conducted on a closed indoor test track and in the laboratory. Results of the technical evaluation demonstrated that under normal use, Segways are stable, easy to manoeuvre, and can stop quickly in case of emergency. An ergonomic evaluation indicated that a wide range of users found Segways easy to use. Results of the behavioural study indicated that the parameters to be taken into account in Segway use included training by a recognized government-certified organization; a set minimum user age of 14; and the wearing of safety helmets. Survey results indicated that Segways may generate transfer to other alternatives to automobiles. Electric scooter evaluation results indicated that the scooters were safe in normal use situations. The addition of horns and helmets was recommended, as well as a minimum user age of 12. It was concluded that Phase 2 of the project be carried out according to procedures established by the project partners in order to evaluate their reliability and safety in urban areas, the social acceptability of scooters and Segways in Quebec, and the ability of the

  7. MIR retrotransposon sequences provide insulators to the human genome

    Science.gov (United States)

    Wang, Jianrong; Vicente-García, Cristina; Seruggia, Davide; Moltó, Eduardo; Fernandez-Miñán, Ana; Neto, Ana; Lee, Elbert; Gómez-Skarmeta, José Luis; Montoliu, Lluís; Lunyak, Victoria V.; Jordan, I. King

    2015-01-01

    Insulators are regulatory elements that help to organize eukaryotic chromatin via enhancer-blocking and chromatin barrier activity. Although there are several examples of transposable element (TE)-derived insulators, the contribution of TEs to human insulators has not been systematically explored. Mammalian-wide interspersed repeats (MIRs) are a conserved family of TEs that have substantial regulatory capacity and share sequence characteristics with tRNA-related insulators. We sought to evaluate whether MIRs can serve as insulators in the human genome. We applied a bioinformatic screen using genome sequence and functional genomic data from CD4+ T cells to identify a set of 1,178 predicted MIR insulators genome-wide. These predicted MIR insulators were computationally tested to serve as chromatin barriers and regulators of gene expression in CD4+ T cells. The activity of predicted MIR insulators was experimentally validated using in vitro and in vivo enhancer-blocking assays. MIR insulators are enriched around genes of the T-cell receptor pathway and reside at T-cell–specific boundaries of repressive and active chromatin. A total of 58% of the MIR insulators predicted here show evidence of T-cell–specific chromatin barrier and gene regulatory activity. MIR insulators appear to be CCCTC-binding factor (CTCF) independent and show a distinct local chromatin environment with marked peaks for RNA Pol III and a number of histone modifications, suggesting that MIR insulators recruit transcriptional complexes and chromatin modifying enzymes in situ to help establish chromatin and regulatory domains in the human genome. The provisioning of insulators by MIRs across the human genome suggests a specific mechanism by which TE sequences can be used to modulate gene regulatory networks. PMID:26216945

  8. MIR retrotransposon sequences provide insulators to the human genome.

    Science.gov (United States)

    Wang, Jianrong; Vicente-García, Cristina; Seruggia, Davide; Moltó, Eduardo; Fernandez-Miñán, Ana; Neto, Ana; Lee, Elbert; Gómez-Skarmeta, José Luis; Montoliu, Lluís; Lunyak, Victoria V; Jordan, I King

    2015-08-11

    Insulators are regulatory elements that help to organize eukaryotic chromatin via enhancer-blocking and chromatin barrier activity. Although there are several examples of transposable element (TE)-derived insulators, the contribution of TEs to human insulators has not been systematically explored. Mammalian-wide interspersed repeats (MIRs) are a conserved family of TEs that have substantial regulatory capacity and share sequence characteristics with tRNA-related insulators. We sought to evaluate whether MIRs can serve as insulators in the human genome. We applied a bioinformatic screen using genome sequence and functional genomic data from CD4(+) T cells to identify a set of 1,178 predicted MIR insulators genome-wide. These predicted MIR insulators were computationally tested to serve as chromatin barriers and regulators of gene expression in CD4(+) T cells. The activity of predicted MIR insulators was experimentally validated using in vitro and in vivo enhancer-blocking assays. MIR insulators are enriched around genes of the T-cell receptor pathway and reside at T-cell-specific boundaries of repressive and active chromatin. A total of 58% of the MIR insulators predicted here show evidence of T-cell-specific chromatin barrier and gene regulatory activity. MIR insulators appear to be CCCTC-binding factor (CTCF) independent and show a distinct local chromatin environment with marked peaks for RNA Pol III and a number of histone modifications, suggesting that MIR insulators recruit transcriptional complexes and chromatin modifying enzymes in situ to help establish chromatin and regulatory domains in the human genome. The provisioning of insulators by MIRs across the human genome suggests a specific mechanism by which TE sequences can be used to modulate gene regulatory networks.

  9. Risk assessment of desert pollution on composite high voltage insulators.

    Science.gov (United States)

    El-Shahat, Mohammed; Anis, Hussein

    2014-09-01

    Transmission lines located in the desert are subjected to desert climate, one of whose features is sandstorms. With long accumulation of sand and with the advent of moisture from rain, ambient humidity and dew, a conductive layer forms and the subsequent leakage current may lead to surface discharge, which may shorten the insulator life or lead to flashover thus interrupting the power supply. Strategically erected power lines in the Egyptian Sinai desert are typically subject to such a risk, where sandstorms are known to be common especially in the spring. In view of the very high cost of insulator cleaning operation, composite (silicon rubber) insulators are nominated to replace ceramic insulators on transmission lines in Sinai. This paper examines the flow of leakage current on sand-polluted composite insulators, which in turn enables a risk assessment of insulator failure. The study uses realistic data compiled and reported in an earlier research project about Sinai, which primarily included grain sizes of polluting sand as well as their salinity content. The paper also uses as a case study an ABB-designed composite insulator. A three-dimensional finite element technique is used to simulate the insulator and seek the potential and electric field distribution as well as the resulting leakage current flow on its polluted surface. A novel method is used to derive the probabilistic features of the insulator's leakage current, which in turn enables a risk assessment of insulator failure. This study is expected to help in critically assessing - and thus justifying - the use of this type of insulators in Sinai and similar critical areas.

  10. Project Startup: Evaluating the Performance of Frito Lay's Electric Delivery Trucks (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2014-04-01

    The Fleet Test and Evaluation Team at the National Renewable Energy Laboratory (NREL) is evaluating the in-service performance of 10 medium-duty Smith Newton electric vehicles (EVs) and 10 comparable conventional diesel vehicles operated by Frito Lay North America in the Seattle, Washington, area. Launched in late 2013, the on-road portion of this 12-month evaluation focuses on collecting and analyzing vehicle performance data, such as fuel economy and maintenance costs, to better understand how to optimize the use of such vehicles in a large-scale commercial operation. In addition to the on-road portion of this evaluation, NREL is analyzing charging data to support total cost of ownership estimations and investigations into smart charging opportunities. NREL is also performing a battery life degradation analysis to quantify battery pack health, track battery performance over time, and determine how various drive cycles and battery charging protocols impact battery life.

  11. Evaluation of electrical propagation delay with cardiomyocytes by photosensitization reaction in vitro

    Science.gov (United States)

    Doi, Marika; Ogawa, Emiyu; Arai, Tsunenori

    2017-02-01

    In order to study cardiomyocyte electrical conduction damage by a photosensitization reaction (PR) mostly comes from outside of the cells in a few minutes after the PR, we studied propagation delay of contact action potential with cardiomyocyte by the PR. To determine appropriate PR condition for tachyarrhythmia ablation, a precise electrophysiological experiment in vitro has been preferable. We measured the contact action potential using a microelectrode array system of which information may be correct than conventional Ca2+ measurement. We investigated the propagation delays of an evoked potential to evaluate the electrical conduction damage by the PR. Rat cardiomyocytes were cultivated for 5-7 days on a dish with which 64 electrodes were patterned, in an incubator controlled to 37°C, 5% CO2. The following conditions were used for the PR: 40 μg/ml talapordfin sodium and 290 mW/cm2, 40-78 J/cm2 for an irradiation. A 2D map was obtained to visualize the propagation delays of the evoked potential. The propagation speed, which was calculated based on the measured propagation delays, was decreased by about 30-50% on average of all electrodes after the PR. Therefore, we think 2D propagation delays measurement of the evoked potential with contact action potential measuring system might be available to evaluate the acute electrical conduction damage of cardiomyocyte by the PR.

  12. Evaluating the use of an urban consolidation centre and electric vehicles in central London

    Directory of Open Access Journals (Sweden)

    Michael Browne

    2011-07-01

    Full Text Available The paper focuses on the role that can be played by urban consolidation centres (UCCs in reducing freight traffic and its environmental impacts in towns and cities. It is based on the before and after evaluation of a trial led by a major stationery and office supplies company in which urban freight deliveries in central London made from a depot in the suburbs using diesel vehicles were replaced with the use of an urban micro-consolidation centre located in the delivery area together with the use of electrically-assisted cargo tricycles and electric vans. The results show that the total distance travelled and the CO2eq emissions per parcel delivered fell by 20% and 54% respectively as a result of this delivery system. However, the evaluation has also indicated that the distance travelled per parcel rose substantially in the City of London delivery area as a result of the electric vehicles having far smaller load limits in both weight and volume compared with diesel vans. But, at the same time, the trial system was able to virtually eliminate CO2eq emissions per parcel delivered in the City of London. The trial proved successful from the company's perspective in transport, environmental and financial terms. The company therefore decided to continue the operation beyond the end of the trial with it being officially launched during 2010.

  13. Evaluation of semiconductor devices for Electric and Hybrid Vehicle (EHV) ac-drive applications, volume 1

    Science.gov (United States)

    Lee, F. C.; Chen, D. Y.; Jovanovic, M.; Hopkins, D. C.

    1985-01-01

    The results of evaluation of power semiconductor devices for electric hybrid vehicle ac drive applications are summarized. Three types of power devices are evaluated in the effort: high power bipolar or Darlington transistors, power MOSFETs, and asymmetric silicon control rectifiers (ASCR). The Bipolar transistors, including discrete device and Darlington devices, range from 100 A to 400 A and from 400 V to 900 V. These devices are currently used as key switching elements inverters for ac motor drive applications. Power MOSFETs, on the other hand, are much smaller in current rating. For the 400 V device, the current rating is limited to 25 A. For the main drive of an electric vehicle, device paralleling is normally needed to achieve practical power level. For other electric vehicle (EV) related applications such as battery charger circuit, however, MOSFET is advantageous to other devices because of drive circuit simplicity and high frequency capability. Asymmetrical SCR is basically a SCR device and needs commutation circuit for turn off. However, the device poses several advantages, i.e., low conduction drop and low cost.

  14. Measurement and Evaluation of Heating Performance of Heat Pump Systems Using Wasted Heat from Electric Devices for an Electric Bus

    Directory of Open Access Journals (Sweden)

    Moo-Yeon Lee

    2012-03-01

    Full Text Available The objective of this study is to investigate heating performance characteristics of a coolant source heat pump using the wasted heat from electric devices for an electric bus. The heat pump, using R-134a, is designed for heating a passengers’ compartment by using discharged energy from the coolant of electric devices, such as motors and inverters of the electric bus. The heating performance of the heat pump was tested by varying the operating parameters, such as outdoor temperature and volume flow rate of the coolant water of the electrical devices. Heating capacity, compressor work, and heating COP were measured; their behaviors with regard to the parameters were observed. Experimental results showed that heating COP increased with decrease of outdoor temperature, from 20.0 °C to 0 °C, and it observed to be 3.0 in the case of 0 °C outdoor temperature. The observed characteristics of the heating COP suggest that the heat pump is applicable as the cabin heater of an electric vehicle, which is limited by short driving range.

  15. Properties of radiation stable insulation composites for fusion magnet

    Science.gov (United States)

    Wu, Zhixiong; Huang, Rongjin; Huang, Chuanjun; Li, Laifeng

    2017-09-01

    High field superconducting magnets made of Nb3Al will be a suitable candidate for future fusion device which can provide magnetic field over 15T without critical current degradation caused by strain. The higher magnetic field and the larger current will produce a huge electromagnetic force. Therefore, it is necessary to develop high strength cryogenic structural materials and electrical insulation materials with excellent performance. On the other hand, superconducting magnets in fusion devices will experience significant nuclear radiation exposure during service. While typical structural materials like stainless steel and titanium have proven their ability to withstand these conditions, electrical insulation materials used in these coils have not fared as well. In fact, recent investigations have shown that electrical insulation breakdown is a limiting factor in the performance of high field magnets. The insulation materials used in the high field fusion magnets should be characterized by excellent mechanical properties, high radiation resistivity and good thermal conductivity. To meet these objectives, we designed various insulation materials based on epoxy resins and cyanate ester resins and investigated their processing characteristic and mechanical properties before and after irradiation at low temperature. In this paper, the recent progress of the radiation stable insulation composites for high field fusion magnet is presented. The materials have been irradiated by 60Co γ-ray irradiation in air at ambient temperature with a dose rate of 300 Gy/min. The total doses of 1 MGy, 5 MGy and 10 MGy were selected to the test specimens.

  16. A novel no-insulation winding technique of high temperature-superconducting racetrack coil for rotating applications: A progress report in Korea university.

    Science.gov (United States)

    Choi, Y H; Song, J B; Yang, D G; Kim, Y G; Hahn, S; Lee, H G

    2016-10-01

    This paper presents our recent progress on core technology development for a megawatt-class superconducting wind turbine generator supported by the international collaborative R&D program of the Korea Institute of Energy Technology Evaluation and Planning. To outperform the current high-temperature-superconducting (HTS) magnet technology in the wind turbine industry, a novel no-insulation winding technique was first proposed to develop the second-generation HTS racetrack coil for rotating applications. Here, we briefly report our recent studies on no-insulation (NI) winding technique for GdBCO coated conductor racetrack coils in the following areas: (1) Charging-discharging characteristics of no-insulation GdBCO racetrack coils with respect to external pressures applied to straight sections; (2) thermal and electrical stabilities of no-insulation GdBCO racetrack coils encapsulated with various impregnating materials; (3) quench behaviors of no-insulation racetrack coils wound with GdBCO conductor possessing various lamination layers; (4) electromagnetic characteristics of no-insulation GdBCO racetrack coils under time-varying field conditions. Test results confirmed that this novel NI winding technique was highly promising. It could provide development of a compact, mechanically dense, and self-protecting GdBCO magnet for use in real-world superconducting wind turbine generators.

  17. Test methods for evaluating energy consumption and emissions of vehicles with electric, hybrid and fuel cell power trains

    NARCIS (Netherlands)

    Smokers, R.T.M.; Ploumen, S.; Conte, M.; Buning, L.; Meier-Engel, K.

    2000-01-01

    As part of the MATADOR-project measurement methods have been developed for the evaluation of the energy consumption and emissions of vehicles with advanced propulsion systems, such as battery-electric, hybrid electric and fuel cell vehicles. Based on an inventory of existing and prospective standard

  18. Materials selection and evaluation of Copper-Tungsten particulate composites for extreme electrical contacts

    Science.gov (United States)

    Watkins, Bobby Gene, II

    2011-12-01

    Materials for extreme electrical contacts need to have high electrical conductivity coupled with good structural properties. Potential applications include motor contacts, high power switches, and the components of electromagnetic launch (EML) systems. The lack of durability experienced with these contact materials limits service life. Due to extreme current densities coupled with the local sliding, electrical contact surfaces can degrade due to a one or more wear mechanisms, including adhesive wear and thermally-assisted wear associated with extreme local Joule heating. A systematic materials selection procedure was developed to identify and compare candidate materials that would be more durable for these types of applications. The most promising materials identified on the Pareto frontier are tungsten alloys. Moreover, several possible candidate monolithic materials as well as hybrid materials that could potentially be even better, filling the "white spaces" on the material property charts, were identified. A couple of these potential candidate materials were obtained and evaluated. These included copper-tungsten W-Cu, "self-lubricating" graphite-impregnated Cu, and Gr-W-Cu composites with different volume fractions of the constituents. The structure-property relations were determined through mechanical and electrical resistivity testing. A unique test protocol for exposing mechanical test specimens to extreme current densities up to 1.2 GA/m2 was developed and used to evaluate these candidate materials. The design of materials including optimizing the microstructure attributes for these applications can potentially be accelerated by using micromechanics modeling and other materials design tools coupled with systematic mechanical and tribological experiments. In this study, physics- and micromechanics-based models were used to correlate properties to the volume fraction of the tungsten. These properties included elastic modulus, hardness, tensile strength, and

  19. Economical noise- and heat insulation

    Energy Technology Data Exchange (ETDEWEB)

    1982-06-01

    All noise protection and heat insulations measures are interlinked. While noise abatement and insulation is primarily a task of health protection, the economically optimised heat insulation is rather a problem for financial mathematics. Parameters, influencing the heat insulation are subject to changes which will affect the profitability of heat insulation measures in turn. Several options for reducing the noise level are described and some standard values for material cost are supplied. Depending on the kind of noise different abatement methods are suitable which require materials with specific properties. Measures for heat insulation are described which to a great extent are identical will noise abatement measures.

  20. A Difference in Using Atomic Layer Deposition or Physical Vapour Deposition TiN as Electrode Material in Metal-Insulator-Metal and Metal-Insulator-Silicon Capacitors

    NARCIS (Netherlands)

    Groenland, A.W.; Wolters, Robertus A.M.; Kovalgin, Alexeij Y.; Schmitz, Jurriaan

    2011-01-01

    In this work, metal-insulator-metal (MIM) and metal-insulator-silicon (MIS) capacitors are studied using titanium nitride (TiN) as the electrode material. The effect of structural defects on the electrical properties on MIS and MIM capacitors is studied for various electrode configurations. In the