  1. Glass heat pipe evacuated tube solar collector

    Science.gov (United States)

    McConnell, Robert D.; Vansant, James H.

    1984-01-01

    A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.

  2. Modified Evacuated-Tube Collector Tested in Solar Simulator

    Science.gov (United States)

    1982-01-01

    According to report, particular commercial evacuated-tube solar collector performs slightly more efficiently with larger manifold. Tests were performed with Marshall Space Flight Center solar simulator. Report describes test conditions and procedures, provides analysis of results, and presents tables and graphs of data, both measured and calculated.

  3. Thermal performance of evacuated tube heat pipe solar collector

    Science.gov (United States)

    Putra, Nandy; Kristian, M. R.; David, R.; Haliansyah, K.; Ariantara, Bambang

    2016-06-01

    The high fossil energy consumption not only causes the scarcity of energy but also raises problems of global warming. Increasing needs of fossil fuel could be reduced through the utilization of solar energy by using solar collectors. Indonesia has the abundant potential for solar energy, but non-renewable energy sources still dominate energy consumption. With heat pipe as passive heat transfer device, evacuated tube solar collector is expected to heat up water for industrial and home usage without external power supply needed to circulate water inside the solar collector. This research was conducted to determine the performance of heat pipe-based evacuated tube solar collector as solar water heater experimentally. The experiments were carried out using stainless steel screen mesh as a wick material, and water and Al2O3-water 0.1% nanofluid as working fluid, and applying inclination angles of 0°, 15°, 30°, and 45°. To analyze the heat absorbed and transferred by the prototype, water at 30°C was circulated through the condenser. A 150 Watt halogen lamp was used as sun simulator, and the prototype was covered by an insulation box to obtain a steady state condition with a minimum affection of ambient changes. Experimental results show that the usage of Al2O3-water 0.1% nanofluid at 30° inclination angle provides the highest thermal performance, which gives efficiency as high as 0.196 and thermal resistance as low as 5.32 °C/W. The use of nanofluid as working fluid enhances thermal performance due to high thermal conductivity of the working fluid. The increase of the inclination angle plays a role in the drainage of the condensate to the evaporator that leads to higher thermal performance until the optimal inclination angle is reached.

  4. Glycol/water evacuated-tube solar collector

    Science.gov (United States)

    1980-01-01

    Report describes performance of 8 tube and 10 tube commercially produced solar collectors. Tests include thermal efficiency, time constant for temperature drop after solar flux is cut, change in efficiency with Sun angle, and temperature rise if circulation is stopped.

  5. Evacuated-tube solar collector--performance evaluation

    Science.gov (United States)

    1980-01-01

    Report gives thermal performance test procedures and results for commercially produced, water-filled, 8-tube collectors. Tests include efficiency, time constant for temperature drop after solar flux is cut, change in efficiency as function of sun angle, and test to see if tubes break when filled with hot water.

  6. Experimental analysis of thermal performance according to heat pipe working fluids for evacuated tube solar collector

    Science.gov (United States)

    Joo, Hong-Jin; Kwak, Hee-Youl

    2017-11-01

    The purpose of this study was to experimentally investigate the thermal performance and operating characteristics of various heat pipe working fluids in evacuated tube solar collectors. Heat pipe efficiency was evaluated by calculating the solar collector efficiency value when using four types of working fluids: water, ethanol, flutec-pp9 and methyl acetate under the same operating conditions on an indoor experiment apparatus. The experimental conditions were as follows: The inclination angle of the evacuated tube solar collectors were 20°, 40° and 60° from the normal basis. The mass flow rate into the manifold of the evacuated tubular solar collector was 0.3 kg/min. The heat flux on the collector surface was 870 W/m2. The results showed that, at an angle of incidence of 40°, the values of {F}R ( {τ α } ) and {F}R {U}L with methyl acetate as the working fluid were 0.6572 and -2.0086, respectively, with water they were 0.6636 and -1.8457, respectively, ethanol they were 0.6147 and -0.6353, respectively, and with flutec-pp9 they were 0.525, and -3.2313, respectively.

  7. Evaluation of an evacuated-tube liquid solar collector

    Science.gov (United States)

    1981-01-01

    Indoor and outdoor thermal performances of collectors are compared in report. Tests conducted on indoor solar simulator with data from both diffuse and specular reflectors are presented graphically and in tables. Comparisons with previous data for prototype show effects of improved mainfold.

  8. Low-cost evacuated-tube solar collector appendices. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Beecher, D.T.

    1980-05-31

    A low cost solar heat energy collector module and array has been designed using the evacuated tube, selective absorber, air cooled concept. Glass tubing as used in fluorescent lamps with automatic sealing methods is a key feature of the evacuated tube design. A molded fiber glass concentrating reflector panel and sheet metal header assembly are proposed. Major design problems involved included the cost of materials and labor, thermal expansion and distortion problems, high stagnation and operating temperatures, isolation, thermal efficiency, sealing, joining, air pressure drop, and weight of the preassembled module. A cost of less than $5 per active square foot of collecting surface has been estimated for materials and labor of the module and its mounting frame.

  9. PERFORMANCE ANALYSIS OF FORCED CONVECTION EVACUATED TUBE SOLAR COLLECTOR USED FOR GRAPE DRYER

    Directory of Open Access Journals (Sweden)

    A. B. UBALE

    2017-01-01

    Full Text Available In the present experimental study an evacuated tube solar collector is designed, fabricated and its performance is tested in the force convection mode of heat transfer. The solar collector is designed for the grape dryer of capacity 10kg per batch. Experiments are carried out in the month of April to produce raisins for Thomson Seedless grapes, with initial moisture content of 77 (kg per kg on wet basis% to final moisture content of 19 (kg per kg on wet basis% in 36 hours. Raisins produced from this system are tested for varies parameters to check its quality and found satisfactory results. The average collector efficiency is found to be 23.4%.

  10. A Study on Thermal Performance of a Novel All-Glass Evacuated Tube Solar Collector Manifold Header with an Inserted Tube

    Directory of Open Access Journals (Sweden)

    Jichun Yang

    2015-01-01

    Full Text Available A novel all-glass evacuated tube collector manifold header with an inserted tube is proposed in this paper which makes water in all-glass evacuated solar collector tube be forced circulated to improve the performance of solar collector. And a dynamic numerical model was presented for the novel all-glass evacuated tube collector manifold header water heater system. Also, a test rig was built for model validation and comparison with traditional all-glass evacuated tube collector. The experiment results show that the efficiency of solar water heater with a novel collector manifold header is higher than traditional all-glass evacuated tube collector by about 5% and the heat transfer model of water heater system is valid. Based on the model, the relationship between the average temperature of water tank and inserted tube diameter (water mass flow has been studied. The results show that the optimized diameter of inserted tube is 32 mm for the inner glass with the diameter of 47 mm and the water flow mass should be less than 1.6 Kg/s.

  11. SOLAR REFRIGERATING UNIT WITH AN ADSORPTION REACTOR AND EVACUATED TUBE COLLECTORS

    Directory of Open Access Journals (Sweden)

    M.E. Vieira

    1997-09-01

    Full Text Available This work presents the principles of operation of a solar refrigerator with the following basic components: a reactor, a set of evacuated tube solar collectors, a condenser, a heat exchanger, and an evaporator. During the heating phase, solar radiation is collected and transferred to the reactor for desorption by a vapor thermal siphon loop. During the cooling phase, heat from the reactor is released to the ambient by a second water vapor loop. Ambient data collected daily during a period of 18 years were divided into hourly values and used to simulate the temperatures of the reactor, which uses salt impregnated with graphite and ammonia, during the adsorption / desorption processes. The results show that the refrigerator operates well in Fortaleza and that better results are expected for the countryside of the state of Ceara. It is concluded that only a high efficiency collector set can be used in the system

  12. Design considerations for residential solar heating and cooling systems utilizing evacuated tube solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Ward, D. S.; Ward, J. C.

    1977-01-01

    As solar heating systems become a commercial reality, greater efforts are now being employed to incorporate solar cooling components in order to obtain a complete solar heating and cooling system, and thus take advantage of the cost-effectiveness of year-round use of the solar equipment. The solar heating and cooling system design presented incorporates design considerations which have been obtained from previous experimental efforts utilizing evacuated tube solar collectors. These advanced collectors are capable of significantly higher efficiencies, even at the higher temperatures required for solar cooling operation. Most of the considerations presented are based on the experience gained in the design and performance of the solar heating and cooling systems for CSU Solar Houses I through IV.

  13. Indoor test for thermal performance of the Sunmaster evacuated tube (liquid) solar collector

    Science.gov (United States)

    1979-01-01

    The test procedures used to obtain the thermal performance data for a solar collector under simulated conditions are presented. Tests included a stagnation test, a time constant test, a thermal efficiency test, an incident angle modifier test, and a hot fill test. All tests were performed at ambient conditions and the transient effect and the incident angle effect on the collector were determined. The solar collector is a water working fluid type.

  14. Theoretical and experimental investigation of Chinese evacuated tubular solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Lin Qin; Furbo, S.

    1999-06-01

    For many years evacuated tubular collectors have been marketed in Europe and the USA. These solar collectors are typically designed on the basis of the heat-pipe principle. Recently a number of Chinese firms started mass production of relatively cheap evacuated tubular solar collectors. The firms produce differently designed evacuated tubular solar collectors, e.g. with different absorbers and glass tube diameters with or without reflectors. As opposed to Europe, in Asia evacuated tubular solar collectors have reached such a low price level and such a high efficiency that in certain types of solar heating systems it has become attractive to use these high-efficient solar collectors instead of ordinary flat-plate collectors. At present the suitability of Chinese evacuated tubular solar collectors for different types of solar heating systems under Danish conditions are investigated at the Technical University of Denmark, DTU. The provisional results of these investigations, which are expected to be finished in the spring of 1999, are described in details in this document. The completed investigations indicate that the thermal performance of a small solar domestic hot water system can be improved if the evacuated tubular solar collector is used instead of a traditional flat-plate collector. However, the investigations indicate the price/performance-ratio of typical Danish small solar domestic hot water systems can not be improved by using evacuated tubular solar collectors instead of traditional flat-plate collector. Furthermore, the investigations indicate that it is not as important for the evacuated tubular solar collectors that the solar collectors are installed with `correct` orientation and tilt as it is for flat-plate collectors. The investigations also showed that it is an advantage for solar heating plants with high operation temperature to use high-efficient evacuated tubular solar collectors. (EHS)

  15. Profitability Variations of a Solar System with an Evacuated Tube Collector According to Schedules and Frequency of Hot Water Demand

    Directory of Open Access Journals (Sweden)

    Carlos J. Porras-Prieto

    2016-12-01

    Full Text Available The use of solar water heating systems with evacuated tube collectors has been experiencing a rapid growth in recent years. Times when there is demand for hot water, the days of use and the volumes demanded may determine the profitability of these systems, even within the same city. Therefore, this paper characterizes the behavior of a solar system with active circulation with the objective of determining the profitability variations according to the timing and schedule of demand. Through a simplified methodology based on regression equations, calculated for each hour of the day based on data from an experimental facility, the useful energy is estimated from the time and frequency of the demand for hot water at 60 °C. The analysis of the potential profitability of the system in more than 1000 scenarios analyzed shows huge differences depending on the number of days when the water is demanded, the time when demand occurs, the irradiation and the average price of energy. In cities with high irradiation and high energy prices, the system could be profitable even in homes where it is used only on weekends. The study of profitability in a building of 10 homes shows that by applying an average European household’s profile for hot water demand, levels close to full potential would be reached; for this, it is necessary to optimize the collection surface.

  16. The sizes of Flat Plate and Evacuated Tube Collectors with Heat Pipe area as a function of the share of solar system in the heat demand

    Directory of Open Access Journals (Sweden)

    Olek Małgorzata

    2016-01-01

    Full Text Available The popularity of solar collectors in Poland is still increasing. The correct location of the collectors and a relatively high density of solar radiation allow delivering heat even in spite of relatively low ambient temperature. Moreover, solar systems used for heating domestic heat water (DHW in summer allow nearly complete elimination of conventional energy sources (e.g. gas, coal. That is why more and more house owners in Poland decide to install solar system installations. In Poland the most common types of solar collectors are flat plate collectors (FPC and evacuated tube collectors with heat pipe (ETCHP; both were selected for the analysis. The heat demand related to the preparation of hot water, connected with the size of solar collectors’ area, has been determined. The analysis includes FPC and ETCHP and heat demand of less than 10 000 kWh/year. Simulations were performed with the Matlab software and using data from a typical meteorological year (TMY. In addition, a 126–year period of measurements of insolation for Krakow has been taken into account. The HDKR model (Hay, Davis, Klucher, Reindl was used for the calculation of solar radiation on the absorber surface. The monthly medium temperature of the absorber depends on the amount of solar system heat and on the heat demand. All the previously mentioned data were used to determine solar efficiency. Due to the fact that solar efficiency and solar system heat are connected, the calculations were made with the use of an iterative method. Additionally, the upper limit for monthly useful solar system heat is resulted from the heat demand and thus the authors prepared a model of statistical solar system heat deviations based on the Monte Carlo method. It has been found that an increase in the useful solar system heat in reference to the heat demand is associated with more than proportional increase in the sizes of the analyzed surfaces of solar collector types.

  17. Theoretical flow investigations of an all glass evacuated tubular collector

    DEFF Research Database (Denmark)

    Shah, Louise Jivan; Furbo, Simon

    2007-01-01

    Heat transfer and flow structures inside all glass evacuated tubular collectors for different operating conditions are investigated by means of computational fluid dynamics. The investigations are based on a collector design with horizontal tubes connected to a vertical 14 manifold channel. Three...... different tube lengths varying from 0.59 in to 1.47 in have been modelled with five different inlet mass flow rates varying from 0.05 kg/min to 10 kg/min with a constant inlet temperature of 333 K. Under these operating conditions the results showed that: the collector with the shortest tube length achieved...... the highest efficiency, the optimal inlet flow rate was around 0.4-1 kg/min, the flow structures in the glass tubes were relatively uninfluenced by the inlet flow rate, Generally, the results showed only small variations in the efficiencies. This indicates that the collector design is well working for most...

  18. Theoretical and experimental investigations of Chinese evacuated tubular solar collectors

    DEFF Research Database (Denmark)

    Qin, Lin; Furbo, Simon

    1999-01-01

    Four different marketed Chinese evacuated tubular solar collectors have been investigated both theoretically and experimentally. The advantages of the investigated solar collectors compared to normal flat plate collectors were elucidated.......Four different marketed Chinese evacuated tubular solar collectors have been investigated both theoretically and experimentally. The advantages of the investigated solar collectors compared to normal flat plate collectors were elucidated....

  19. Indoor test for the thermal performance evaluation of the DEC 8A large manifold sunmaster evacuated tube (liquid) solar collector

    Science.gov (United States)

    1981-01-01

    The Sunmaster DEC 8A Large Manifold solar collector using simulated conditions was evaluated. The collector provided 17.17 square feet of gross collector area. Test conditions, test requirements, an analysis of results, and tables of test data are reported.

  20. Solar Heating Systems with Evacuated Tubular Solar Collector

    DEFF Research Database (Denmark)

    Qin, Lin; Furbo, Simon

    1998-01-01

    Recently different designed evacuated tubular solar collectors were introduced on the market by different Chinese companies. In the present study, investigations on the performance of four different Chinese evacuated tubular collectors and of solar heating systems using these collectors were...... carried out, employing both laboratory test and theoretical calculations. The collectors were tested in a small solar domestic hot water (SDHW) system in a laboratory test facility under realistic conditions. The yearly thermal performance of solar heating systems with these evacuated tubular collectors......-plate collectors. For solar heating plants, the yearly energy output from these evacuated tubular collectors is about 40%-90% higher than the output from typical flat-plate collectors at an operation temperature of about 50°C....

  1. Fin-tube solar collectors

    Science.gov (United States)

    1980-01-01

    Report presents test procedures and results of thermal-performance evaluation of seven commercial fin tube (liquid) solar collector-absorber plates. Tests were conducted indoors at Marshall Space Flight Center Solar simulator. Results are graphically shown along with supporting test data and summary, indicating efficiency as function of collector inlet temperature.

  2. Experimental analysis of solar thermal integrated MD system for cogeneration of drinking water and hot water for single family villa in dubai using flat plate and evacuated tube solar collectors

    DEFF Research Database (Denmark)

    Asim, Muhammad; Imran, Muhammad; Leung, Michael K.H.

    2017-01-01

    This paper presents the experimental analysis performed on solar thermal integrated membrane distillation (MD) system using flat plate and evacuated tube collectors. The system will be utilized for cogeneration of drinking water and domestic hot water for single family in Dubai comprising of four...... on MD setup at optimized flow rates of 6 L/min on hot side and 3 L/min on cold side for producing the desired distillate. The hot side and cold side MD temperature has been maintained between 60°C and 70°C, and 20°C and 30°C. The total annual energy demand comes out to be 8,223 kWh (6,000 k...

  3. VALIDATION OF SIMULATION MODELS FOR DIFFERENTLY DESIGNED HEAT-PIPE EVACUATED TUBULAR COLLECTORS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Dragsted, Janne; Furbo, Simon

    2007-01-01

    Differently designed heat-pipe evacuated tubular collectors have been investigated theoretically and experimentally. The theoretical work has included development of two TRNSYS [1] simulation models for heat-pipe evacuated tubular collectors utilizing solar radiation from all directions. One model...... is developed for heat-pipe evacuated tubular collectors with flat fins and one model is developed for heat-pipe evacuated tubular collectors with curved fins. The models are characterized by detailed calculations of the heat transfer processes in the fins, by detailed shadow modeling and by fins with selective...... coating on both sides. The input to the models is thus not a simple collector efficiency expression but the actual collector geometry. In this study, the TRNSYS models are validated with measurements for four differently designed heat-pipe evacuated tubular collectors. The collectors are produced...

  4. EVALUATION OF EVACUATED TUBULAR SOLAR COLLECTORS FOR LARGE SDHW SYSTEMS AND COMBINED SPACE HEATING SYSTEMS

    DEFF Research Database (Denmark)

    Qin, Lin; Furbo, Simon

    1999-01-01

    . Based on thesemodels, the thermal performance of large solar domestic hot water (DHW) systems and combined domestichot water and space heating systems with the four evacuated tubular collectors was determined. To make acomparison with traditional flat-plate collectors, similar simulations were also......In the present study, detailed investigations on evacuated tubular solar collectors for large solarheating systems have been carried out. Four types of evacuated tubular solar collectors were used in theinvestigation. Based on laboratory tests, simulation models for the collectors were determined...... carried out for systems with atypical flat-plate collector. The results show that the thermal advantage of evacuated tubular collectors variesgreatly from system to system, and increases with the solar fraction. Furthermore, the higher the operationtemperature of the collector in the system is...

  5. An experimental study on single basin solar still augmented with evacuated tubes

    Directory of Open Access Journals (Sweden)

    Sampathkumar K.

    2012-01-01

    Full Text Available The productivity of the solar still is determined by the temperature of water in the basin and the glass temperature. Various active methods have been adopted to increase the temperature of the basin, so as to improve the productivity of solar still. Most of the previous research works have been focusing on flat plate collector and concentrating collector. In this experimental study, a single slope solar still directly augmented with evacuated tubes was used to increase the daily productivity by reducing heat losses. Evacuated tubes were directly coupled to the lower side of the single slope solar still with an area of 1m2. Black gravel is used to increase the productivity by means of reducing quantity of water in the basin. Extensive experiments were conducted to explore the performance of solar still in several modes namely still alone, still with black stones, still with evacuated tubes, and still with evacuated tubes and black gravel. The experimental setup was designed and installed at Solar Energy Park, Tamilnadu College of Engineering, Coimbatore (77˚E, 11˚N, Tamilnadu, India. These experiments were conducted using tap water as feed. It was found that, after augmentation of the evacuated tubes, the daily production rate has increased by 49.7 % and it increased by 59.48% with black stones. Economic analysis was also done and payback period of this experimental setup is 235 days.

  6. A Long Term Test of Differently Designed Evacuated Tubular Collectors

    DEFF Research Database (Denmark)

    Fan, Jianhua; Dragsted, Janne; Furbo, Simon

    2008-01-01

    and one direct flow ETC from Sunda Technolgoy Co. Ltd and one all-glass ETC with heat pipe from Exoheat AB. The collectors have been investigated side-by-side in an outdoor test facility for a long period. During the measurements, the operating conditions – such as weather conditions and temperature....... Further, the collector performances are compared for different times of the year and it is illustrated how the performance of the different collector types depends on weather conditions....

  7. Design and modelling of novel evacuated receiver tube of concentration solar power system by using heliostat stadium arrangement

    Directory of Open Access Journals (Sweden)

    Kadhim Khlief Ayad

    2017-01-01

    Full Text Available A novel concentration solar evacuated receiver tube collector is proposed in this study. Details of design and simulation of the heliostat field are presented. The proposed system uses a heliostat stadium arrangement to focus sunlight towards a receiver (evacuated receiver tube. Heliostat field which looks like stadium arrangement is proposed an alternative system of the tower in the power tower plants to cancel the shading / blocking losses. In this study, simulation results showed that the energy input increases with increased solar irradiation; the increase ranges from 288 to 470W/m.The maximum amount of energy inputs that can be obtained in the receiver for the collector is around 470W/m for the maximum solar density of 688W.m2. In the solar is 402 W/m2, and the useful energy of collectors is about 288 W/m and the thermal efficiency of the receiver was around 23%.

  8. Indoor tests of the concentric-tube solar collector

    Science.gov (United States)

    1980-01-01

    Report describes performance tests on 12-tube, liquid-filled collector. Thermal efficiency, change in efficiency with sun position, and time constant for temperature drop after solar flux is cut are described.

  9. Final report on the concentric-tube solar collector

    Science.gov (United States)

    Parker, J. C.

    1980-01-01

    Report documents 26-month program to optimize performance of commercial high performance concentric tube solar collector. Report discusses program objectives, accomplishments, encountered problems, and final hardware. Certification test results are also included.

  10. Effect of the collector tube profile on Pitot pump performances

    Science.gov (United States)

    Komaki, K.; Kanemoto, T.; Sagara, K.; Umekage, T.

    2013-12-01

    The pitot pump is composed of the rotating casing with the impeller channel and the pitot tube type collector as the discharge line. The radial impeller feeds water to the rotating casing. The water rotating together with the casing is caught by the stationary pitot tube type collector, and then discharges to the outside. This type pump, as the extra high head pump, is provided mainly for boiler feed systems, and has been designed by trial and error. To optimize the pump profiles, it is desirable to investigate not only performances but also internal flow conditions. This paper discusses experimentally and numerically the relation between the pump performances and the flow conditions in the rotating casing. The moderately larger dimensions of the collector make the pump head and the discharge high with the higher hydraulic efficiency. The flow in the casing is almost the forced vortex type whose velocity is in proportion to the radius but the core velocity is affected with the drag force of the stationary collector. Based upon the above results, the profile of the pitot tube type collector was optimized with the numerical simulation.

  11. Evacuated tubular collector utilizing a heat pipe. Progress report, May 1 1975--August 31, 1975

    Energy Technology Data Exchange (ETDEWEB)

    Ortabasi, U.; Fehlner, F.P.

    1975-01-01

    Research and development activities performed by the Corning Glass Works solar group during the period from May 1, 1975 to August 31, 1975 are reported. The analytical studies encompassed optical modeling of a modified cusp reflector, fresnel losses from tubular enclosures as a function of orientation, preliminary work on a digital Monte-Carlo Ray Tracing Computer Code and the determination of U/sub L/ losses as a function of vacuum level and temperature of the absorber. Compatible enclosure materials, wicks and working fluids were selected to assemble heat pipes for use as solar collector absorbers. Cusp reflectors with good accuracy were fabricated from various commercial bright aluminum sheet and their optical properties determined. Evacuation techniques were developed and special bake-out procedures were worked out to assemble the evacuated tubular collectors. The work on selective coatings narrowed down the field of potential absorber films to ''black chrome'' which has good stability in vacuum and the necessary ..cap alpha../epsilon value. Six different heat pipes and one flow-through absorber were fabricated and were partially characterized for thermal performance. Indoor and outdoor test facilities were completed and calibrated within proposed NBS standards. They are now available for parametric as well as true-life experiments with solar radiation.

  12. MINICHANNEL-TUBE SOLAR THERMAL COLLECTORS FOR LOW TO MEDIUM TEMPERATURE APPLICATIONS

    OpenAIRE

    Duong, Thuc

    2015-01-01

    Novel minichannel-tube solar thermal collectors for low to medium temperature applications are introduced. Two types of minichannel solar thermal collectors are analyzed experimentally: aluminum minichannel solar collector for low temperature applications, and copper minichannel solar collector for low to medium temperature applications.The aluminum minichannel solar collector has been tested for over a year alongside a conventional copper flat-plate solar collector of similar dimensions as t...

  13. A simple method for preparing superconducting FeSe pellets without sealing in evacuated silica tubes

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude

    2017-01-01

    Superconducting tetragonal FeSe pellets were made by reacting mixtures of elemental Fe and Se powders in argon atmosphere without sealing in evacuated silica tubes. A simple tube furnace has been used. Although the tube's material consisted of quartz, an alumina tube could be used as well. X-ray ...

  14. High-performance solar collector

    Science.gov (United States)

    Beekley, D. C.; Mather, G. R., Jr.

    1979-01-01

    Evacuated all-glass concentric tube collector using air or liquid transfer mediums is very efficient at high temperatures. Collector can directly drive existing heating systems that are presently driven by fossil fuel with relative ease of conversion and less expense than installation of complete solar heating systems.

  15. Artificial Neural Networks-Based Software for Measuring Heat Collection Rate and Heat Loss Coefficient of Water-in-Glass Evacuated Tube Solar Water Heaters.

    Science.gov (United States)

    Liu, Zhijian; Liu, Kejun; Li, Hao; Zhang, Xinyu; Jin, Guangya; Cheng, Kewei

    2015-01-01

    Measurements of heat collection rate and heat loss coefficient are crucial for the evaluation of in service water-in-glass evacuated tube solar water heaters. However, conventional measurement requires expensive detection devices and undergoes a series of complicated procedures. To simplify the measurement and reduce the cost, software based on artificial neural networks for measuring heat collection rate and heat loss coefficient of water-in-glass evacuated tube solar water heaters was developed. Using multilayer feed-forward neural networks with back-propagation algorithm, we developed and tested our program on the basis of 915 measured samples of water-in-glass evacuated tube solar water heaters. This artificial neural networks-based software program automatically obtained accurate heat collection rate and heat loss coefficient using simply "portable test instruments" acquired parameters, including tube length, number of tubes, tube center distance, heat water mass in tank, collector area, angle between tubes and ground and final temperature. Our results show that this software (on both personal computer and Android platforms) is efficient and convenient to predict the heat collection rate and heat loss coefficient due to it slow root mean square errors in prediction. The software now can be downloaded from http://t.cn/RLPKF08.

  16. Theoretical and experimental validation of evacuated tubes directly coupled with solar still

    Science.gov (United States)

    Panchal, H. N.; Thakkar, H.

    2016-11-01

    Experimental study of evacuated tubes coupled solar still in the climatic conditions of Mehsana, a region of North Gujarat, India during summer and winter climate conditions has been made. Experimental setup was made by authors. Fourteen double-walled hard borosilicate glass tubes have been used. Evacuated tubes were inclined at angle of 45° from horizontal. Outer tubes of evacuated tubes were transparent, inner tubes were coated with a selective coating of Al-Ni/Al compound for better solar radiation absorption and minimum emittance. It has been shown that evacuated tube attachments to the solar still increased the water temperature inside the solar still for increment in the generation of distillate output. Evacuated tubes coupled solar still is not only produce distilled water during sunshine hours, but also off-sunshine hours due to heat storage effect. For the validation of the experimental results, a theoretical model is proposed based on the fundamentals of heat and mass transfer equations for solar still glass cover, water in basin and basin bottom. Two main statistical parameters—root mean square error and mean bias error—were calculated to compare the results of experiments and theoretical analysis. Closed matching of the experimental and theoretical results has been found.

  17. Study of Performance of Coaxial Vacuum Tube Solar Collector on Ethanol Distillation Process

    Science.gov (United States)

    Sutomo; Ramelan, A. H.; Mustafa; Tristono, T.

    2017-07-01

    Coaxial vacuum tube solar collectors can generate heat up to 80°C is possibly used for ethanol distillation process that required temperature 79°C only. This study reviews the performance of coaxial collector vacuum tube used for ethanol distillation process. This experimental research was conducted in a closed space using a halogen lamp as a solar radiation simulator. We had done on three different of the radiation values, i.e. 998 W/m2, 878 W/m2 and 782 W/m2. The pressure levels of vacuum tube collector cavity in the research were 1; 0.5; 0.31; 0.179; and 0.043 atmospheres. The Research upgraded the 30% of ethanol to produce the concentration of 77% after distillation. The result shows that the performance of coaxial collector vacuum tube used for ethanol distillation process has the negative correlation to the level of the collector tube cavity pressure. The productivity will increase while the collector tube cavity pressure decreased. Therefore, the collector efficiency has the negative correlation also to the level of collector tube cavity pressure. The best performance achieved when it operated at a pressure of 0.043 atmosphere with radiation intensity 878 W / m2, and the value of efficiency is 57.8%.

  18. Performance of evacuated tubular solar collectors in a residential heating and cooling system. Final report, 1 October 1978-30 September 1979

    Energy Technology Data Exchange (ETDEWEB)

    Duff, W.S.; Loef, G.O.G.

    1981-03-01

    Operation of CSU Solar House I during the heating season of 1978-1979 and during the 1979 cooling season was based on the use of systems comprising an experimental evacuated tubular solar collector, a non-freezing aqueous collection medium, heat exchange to an insulated conventional vertical cylindrical storage tank and to a built-up rectangular insulated storage tank, heating of circulating air by solar heated water and by electric auxiliary in an off-peak heat storage unit, space cooling by lithium bromide absorption chiller, and service water heating by solar exchange and electric auxiliary. Automatic system control and automatic data acquisition and computation are provided. This system is compared with others evaluated in CSU Solar Houses I, II and III, and with computer predictions based on mathematical models. Of the 69,513 MJ total energy requirement for space heating and hot water during a record cold winter, solar provided 33,281 MJ equivalent to 48 percent. Thirty percent of the incident solar energy was collected and 29 percent was delivered and used for heating and hot water. Of 33,320 MJ required for cooling and hot water during the summer, 79 percent or 26,202 MJ were supplied by solar. Thirty-five percent of the incident solar energy was collected and 26 percent was used for hot water and cooling in the summer. Although not as efficient as the Corning evacuated tube collector previously used, the Philips experimental collector provides solar heating and cooling with minimum operational problems. Improved performance, particularly for cooling, resulted from the use of a very well-insulated heat storage tank. Day time (on-peak) electric auxiliary heating was completely avoided by use of off-peak electric heat storage. A well-designed and operated solar heating and cooling system provided 56 percent of the total energy requirements for heating, cooling, and hot water.

  19. Results of thermal performance evaluation of the Owens-Illinois sunpack liquid solar collector at indoor conditions

    Science.gov (United States)

    1979-01-01

    Test procedures and results of the thermal performance of a liquid, evacuated tube, solar collector under simulated conditions are presented. The collector tested was a module used on the early demonstration projects.

  20. SIDE-BY-SIDE TESTS OF DIFFERENTLY DESIGNED EVACUATED TUBULAR COLLECTORS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Dragsted, Janne; Furbo, Simon

    2007-01-01

    . and one all-glass ETC with heat pipe from Exoheat AB. The collectors have been investigated side-by-side in an outdoor test facility for a long period. During the measurements, the operating conditions – such as weather conditions, inlet and mean solar collector fluid temperatures have been the same. Thus...

  1. CFD Study of Fluid Flow in an All-glass Evacuated Tube Solar Water Heater

    DEFF Research Database (Denmark)

    Ai, Ning; Fan, Jianhua; Li, Yumin

    2008-01-01

    Abstract: The all-glass evacuated tube solar water heater is one of the most widely used solar thermal technologies. The aim of the paper is to investigate fluid flow in the solar water heater by means of computational fluid dynamics (CFD). The investigation was carried out with a focus...

  2. Indoor test for thermal performance evaluation of seven Elcam fin-tube solar collector configurations

    Science.gov (United States)

    1979-01-01

    The test procedure used and the results obtained from an evaluation test program conducted to obtain thermal performance data on seven Elcam fin-tube solar collector configurations under simulated conditions are described. These tests were made using the Marshall Space Flight Center solar facilities. The Elcam fin-tube (liquid) solar collectors each consist of an absorber plate 5.9 inches wide by 83 inches long and a type M copper tube of 0.569 inch nominal inside diameter. No cover plate was used with any of the specimens. The uniqueness of each of the seven configurations is described, and tests were performed on each separate configuration.

  3. Viability of use of PVC tubes in solar collectors: an analysis of materials

    Directory of Open Access Journals (Sweden)

    Souza Luiz Guillherme Meira de

    2003-01-01

    Full Text Available This paper presents a study of the inherent degradations of PVC tubes due to the thermal effect and ultraviolet solar radiation. The approach relates its causes and its effect of use of the PVC tubes as elements to absorption, forming a coil, in solar collectors for water heating. It is demonstrated that such degradations can be burst through the use of an outflow and an appropriate regimen of work, as well as of a protective layer for the tubes, in this case black ink used to magnify its absorption. The results of the properties of tubes that had been exposed to the degradation effect for up to five years are presented. The viability of use of this type of collector is demonstrated through comparative analysis of tubes exposed and not exposed to the sun, concluding for the low cost, easy assembly and maintenance of the system.

  4. Comparative Study on Solar Collector's Configuration for an Ejector-Refrigeration Cycle

    OpenAIRE

    Senjaya, Raffles; Astina, I Made

    2008-01-01

    Solar collector's configuration plays important role on solar-powered refrigeration systems to work as heat source for generator . Three types of solar collector consisting of flat plate, evacuated tube, and compound parabolic solar collectors are compared to investigate their performances. The performances consist of the behavior of heat which can be absorbed by the collectors, heat loss from the collectors and outlet temperature of working fluid at several slopes of the solar...

  5. Direct solar steam generation inside evacuated tube absorber

    Directory of Open Access Journals (Sweden)

    Khaled M. Bataineh

    2016-12-01

    Full Text Available Direct steam generation by solar radiation falling on absorber tube is studied in this paper. A system of single pipe covered by glass material in which the subcooled undergoes heating and evaporation process is analyzed. Mathematical equations are derived based on energy, momentum and mass balances for system components. A Matlab code is built to simulate the flow of water inside the absorber tube and determine properties of water along the pipe. Widely accepted empirical correlations and mathematical models of turbulent flow, pressure drop for single and multiphase flow, and heat transfer are used in the simulation. The influences of major parameters on the system performance are investigated. The pressure profiles obtained by present numerical solution for each operation condition (3 and 10 MPa matches very well experimental data from the DISS system of Plataforma Solar de Almería. Furthermore, results obtained by simulation model for pressure profiles are closer to the experimental data than those predicted by already existed other numerical model.

  6. Metal glass vacuum tube solar collectors are approaching lower-medium temperature heat application.

    Science.gov (United States)

    Jiang, Xinian

    2010-04-26

    Solar thermal collectors are widely used worldwide mainly for hot water preparation at a low temperature (less than 80?C). Applications including many industrial processes and central air conditioning with absorption chillers, instead require lower-medium temperature heat (between 90 degrees C and 150 degrees C) to be driven when using solar thermal energy. The metal absorber glass vacuum tube collectors (MGVT) are developed for this type of applications. Current state-of-art and possible future technology development of MGVT are presented.

  7. COMBINED UNCOVERED SHEET-AND-TUBE PVT-COLLECTOR SYSTEM WITH BUILT-IN STORAGE WATER HEATER

    Directory of Open Access Journals (Sweden)

    Muhammad Abid

    2012-02-01

    Full Text Available This work describes the design and investigation of a simple combined uncovered sheet-and-tube photo-voltaic-thermal (PVT collector system. The PVT-collector system consists of a support, standard PV module (1.22x0.305m, area=0.37m2, fill factor=0.75, sheet-and-tube water collector and storage tank-heater. The collector was fixed under PV module. Inclination angle of the PVT-collector to the horizontal plane was 45 degree. The storage tank-heater played double role i.e. for storage of hot water and for water heating. The PVT-collector system could work in the fixed and tracking modes of operation. During investigations of PVT-collector in natural conditions, solar irradiance, voltage and current of PV module, ambient temperature and water temperature in storage tank were measured. Average thermal and electrical powers of the PVT-collector system at the tracking mode of operation observed were 39W and 21W, with efficiencies of 15% and 8% respectively at the input power of 260W. The maximum temperature of the water obtained was 42oC. The system was observed efficient for low-temperature applications. The PVT-collector system may be used as a prototype for design of PVT-collector system for domestic application, teaching aid and for demonstration purposes.

  8. Absorber Tube with Internal Pin-Fins for Solar Parabolic Trough Collector

    Directory of Open Access Journals (Sweden)

    Kalidasan B.

    2016-01-01

    Full Text Available Solar parabolic trough collectors exploit solar energy for power generation in solar thermal power stations. These systems require long arrays of reflective troughs with absorber tube running along the axis of parabolic dish. A successful attempt to reduce the length of arrays was accomplished by experimentally analysing the modifications done in absorber tube. Two out of three tubes were fabricated and they were employed to obtain the performance parameters through experimentation conducted at VIT University, Vellore, India. Distilled water was used as the working fluid. Maximum efficiency of 39.12% was obtained at 451.6 W/m2 of direct normal irradiance (DNI for absorber tube with internal pin-fins and without glass tube (AFWGt compared to 8.15% obtained at same value of DNI and other conditions for simple absorber tube without glass cover (AWGt. Cylindrical parabolic trough available at the university was utilized, providing the basis for designing and fabrication of the tubes. Plots for varying mass flow rate at interval of 10 minutes were made against instantaneous thermal efficiency and heat utilized, for direct normal irradiance vs. temperature difference across the tubes and instantaneous thermal efficiency. Through the experimentation conducted, better performance was procured compared to earlier works. Thus, the proposal infers that absorber tube with internal fins has good scope for its application, both domestically as well as industrially. It also calls for further research and development of proposed techniques so as to achieve better performance curves.

  9. Theoretical modeling and experimental analysis of solar still integrated with evacuated tubes

    Science.gov (United States)

    Panchal, Hitesh; Awasthi, Anuradha

    2017-06-01

    In this present research work, theoretical modeling of single slope, single basin solar still integrated with evacuated tubes has been performed based on energy balance equations. Major variables like water temperature, inner glass cover temperature and distillate output has been computed based on theoretical modeling. The experimental setup has been made from locally available materials and installed at Gujarat Power Engineering and Research Institute, Mehsana, Gujarat, India (23.5880°N, 72.3693°E) with 0.04 m depth during 6 months of time interval. From the series of experiments, it is found considerable increment in average distillate output of a solar still when integrated with evacuated tubes not only during daytime but also from night time. In all experimental cases, the correlation of coefficient (r) and root mean square percentage deviation of theoretical modeling and experimental study found good agreement with 0.97 < r < 0.98 and 10.22 < e < 38.4% respectively.

  10. Novel Method for Measuring the Heat Collection Rate and Heat Loss Coefficient of Water-in-Glass Evacuated Tube Solar Water Heaters Based on Artificial Neural Networks and Support Vector Machine

    Directory of Open Access Journals (Sweden)

    Zhijian Liu

    2015-08-01

    Full Text Available The determinations of heat collection rate and heat loss coefficient are crucial for the evaluation of in service water-in-glass evacuated tube solar water heaters. However, the direct determination requires complex detection devices and a series of standard experiments, which also wastes too much time and manpower. To address this problem, we propose machine learning models including artificial neural networks (ANNs and support vector machines (SVM to predict the heat collection rate and heat loss coefficient without a direct determination. Parameters that can be easily obtained by “portable test instruments” were set as independent variables, including tube length, number of tubes, tube center distance, heat water mass in tank, collector area, final temperature and angle between tubes and ground, while the heat collection rate and heat loss coefficient determined by the detection device were set as dependent variables respectively. Nine hundred fifteen samples from in-service water-in-glass evacuated tube solar water heaters were used for training and testing the models. Results show that the multilayer feed-forward neural network (MLFN with 3 nodes is the best model for the prediction of heat collection rate and the general regression neural network (GRNN is the best model for the prediction of heat loss coefficient due to their low root mean square (RMS errors, short training times, and high prediction accuracies (under the tolerances of 30%, 20%, and 10%, respectively.

  11. Mathematical Modeling of a developed Central Receiver Based on Evacuated Solar Tubes

    Directory of Open Access Journals (Sweden)

    Ali Basil. H.

    2016-01-01

    Full Text Available Solar central receiver plays a considerable role in the plant output power; it is one of the most important synthesis in the solar power tower plants. Its performance directly affects the efficiency of the entire solar power generation system. In this study, a new designed receiver model based on evacuated solar tube was proposed, and the dynamic characteristics of the developed receiver were investigated. In order to optimise and evaluate the dynamic characteristics of solar power plant components, the model investigates the solar radiation heat conversion process through the developed receiver, where the energy and mass conservation equations are used to determine the working fluid temperature and state through the receiver parts, beside the calculation and analysis of the thermal losses.

  12. Experimental investigation of forced-convection in a finned rhombic tube of the flat-plate solar collectors

    DEFF Research Database (Denmark)

    Taherian, Hessam; Yazdanshenas, Eshagh

    2006-01-01

    Due to scarcity of literature on forced-convection heat transfer in a solar collector with rhombic cross-section absorbing tubes, a series of experiments was arranged and conducted to determine heat transfer coefficient. In this study, a typical rhombic cross-section finned tube of flat......-plate collectors used as the test section. Two correlations were proposed for the Nusselt number as a function of the Reynolds number and the Prandtl number based on hydraulic diameter for various heat fluxes. The temperature distribution along the finned tube for the fluid and the wall were also illustrated....

  13. A Comparison of the Thermodynamic Efficiency of Vacuum Tube and Flat Plate Solar Collector Systems

    Directory of Open Access Journals (Sweden)

    Juozas Bielskus

    2013-12-01

    Full Text Available The article presents simulation based exergy analysis used for comparing solar thermal systems applied for preparing domestic hot water. The simulation of flat and vacuum tube solar collector systems was performed in TRNSYS simulation environment. A period of one year under Lithuanian climate conditions was chosen. Simulation was performed on 6 min time step resolution by calculating energy and exergy flows and creating balance calculation. Assessment results at system and element levels have been presented as monthly variation in efficiency. The conducted analysis has revealed that the systems designed to cover equal heat energy demand operates in different exergetic efficiencies.Article in Lithuanian

  14. Evaluation performance of helix tube solar collector from nano carbon composite

    Energy Technology Data Exchange (ETDEWEB)

    Boonchom, K. [Rajabhat ChiangMai Univ., ChiangMai (Thailand). Faculty of Science and Technology; Vorasingha, A.; Bongran, T. [Naresuan Univ., Phitsanuloke (Thailand). Faculty of Science; Ketjoy, N. [Naresuan Univ., Phitsanuloke (Thailand). School of Renewable Energy; Souvakon, C. [Rajabhat Uttaradit Univ., Uttaradit , (Thailand). Faculty of Science and Technology

    2006-07-01

    Hot fluid is an essential requirement in both the domestic and industrial sectors. Reducing electricity consumption and energy costs as well as reducing environmental pollution are concerns that have led to the search for more viable and efficient renewable energy sources. A helix tube solar oil heater was designed and manufactured for preheating water in the distillation process of natural products and to preheat seed oil or vegetable oil in the production of bio-diesel. The thermal performance was evaluated by using solar radiation data from the province of Phitsanuloke, Thailand as well as optical parameter absorbance and infrared emissions of nano carbon composite. A solar collector is a device that absorbs the incoming solar radiation, converts it into heat, and then subsequently transfer this heat to a fluid (usually air, water, or oil) flowing through the collector. The design, thermal analysis of collectors, and results and discussion were presented in this paper. It was concluded that there is a good capability of the system to convert the solar energy to heat. 15 refs., 6 tabs., 4 figs.

  15. Multiple-effect diffusion solar still coupled with a vacuum-tube collector and heat pipe

    KAUST Repository

    Chong, Tze-Ling

    2014-08-01

    The present study develops a multiple-effect diffusion solar still (MEDS) with a bended-plate design in multiple-effect diffusion unit (MDU) to solve the peel-off problem of wick material. The MDU is coupled with a vacuum-tube solar collector to produce a high temperature gradient for high productivity. A heat pipe is used to transfer the solar heat to the MDU. A prototype MEDS-1L was built and tested outdoors. Four performance indexes are proposed for the performance evaluation of MEDS, including daily pure water production per unit area of glass cover, solar absorber, and evaporating surface (Mcov, Msol, Mevp, respectively), and solar distillation efficiency Rcov. The outdoor test results of MEDS-1L show that the solar collector supply temperature Th reaches 100°C at solar radiation 800Wm-2. The highest Mcov is 23.9kgm-2d-1 which is about 29% higher than the basin-type MEDS [11]. The highest value is 25.9kgm-2d-1 for Msol and 2.79kgm-2d-1 for Mevp. The measured Rcov is 1.5-2.44, higher than the basin-type MEDS (1.45-1.88). The Mcov, Msol, Mevp and Rcov of MEDS-1L are all higher than the theoretical calculation of a MEDS with a flat-plate solar collector coupled with a heat pipe (MEDS-FHP) [17].© 2014 Elsevier B.V.

  16. A vacuum tube vee-trough collector for solar heating and air conditioning applications

    Science.gov (United States)

    Selcuk, M. K.

    1978-01-01

    An analysis is conducted of the performance of a vee-trough vacuum tube collector proposed for use in solar heating and cooling applications. The vee-trough reflector is a triangular sectioned, flat surfaced reflector, whose axis is laid in the East-West direction. A vacuum tube receiver placed at the bottom of the vee-trough collects solar heat most efficiently since convection is completely eliminated. Radiation losses are reduced by use of selective coatings on the absorber. Owing to its high temperature capabilities (300-400 F), the proposed scheme could also be used for power generation applications in combination with an organic Rankine conversion system. It is especially recommended for unattended pumping stations since the reflectors only require reversal once every six months.

  17. Investigation of Thermal Performance of Flat Plate and Evacuated Tubular Solar Collectors According to a New Dynamic Test Method

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Wang, Zhifeng; Fan, Jianhua

    2012-01-01

    A new dynamic test method is introduced. This so called improved transfer function method features on two new collector parameters. One is time term which can indicate solar collector's inner heat transfer ability and the other is a second order term of collector mean fluid temperature which can...... obtain fluid thermal capacitance in data processing. Then theoretical analysis and experimental verification are carried out to investigate influencing factors of obtaining accurate and stable second order term. A flat plate and ETC solar collector are compared using both the new dynamic method...... and a standard method. The results show that the improved function method can accurately and robustly estimate these two kinds of solar collectors....

  18. Design and Optical Performance of Compound Parabolic Solar Concentrators with Evacuated Tube as Receivers

    Directory of Open Access Journals (Sweden)

    Qiang Wang

    2016-10-01

    Full Text Available In the present article, six symmetric compound parabolic solar concentrators (CPCs with all-glass evacuated solar tubes (EST as the receiver are designed, and a comparative study on their optical performance is performed based on theoretical analysis and ray-tracing simulations. In terms of optical loss through gaps of CPCs and optical efficiency averaged for radiation over the acceptance angle, CPC-6, designed based on a fictitious “hat”-shaped absorber with a “V” groove at the bottom, is the optimal design, and CPC-1, designed based on the cover tube, is the worst solution, whereas from the point of view of the annual collectible radiation on the EST, it is found that CPC-4, designed based on a fictitious “ice-cream” absorber, is the optimal design and CPC-1 is the worst solution. CPC-6, commonly regarded as the best design in the past, is not an optimal design in terms of annual collectible radiation after truncation. Results also indicate that, for high temperature applications, CPC-6 and CPC-4 are advisable due to the high solar flux on the EST resulting from the high optical efficiency for radiation within the acceptance angle.

  19. Design and Optimization of Elliptical Cavity Tube Receivers in the Parabolic Trough Solar Collector

    Directory of Open Access Journals (Sweden)

    Fei Cao

    2017-01-01

    Full Text Available The nonfragile cavity receiver is of high significance to the solar parabolic trough collector (PTC. In the present study, light distributions in the cavity under different tracking error angles and PTC configurations are analyzed. A new elliptical cavity geometry is proposed and analyzed. It is obtained from this study that light distribution on the tube receiver is asymmetrical when tracking error occurs. On increasing the tracking error angle, more lights are sheltered by the cavity outer surface. The PTC focal distance has negative correlation with the cavity open length, whereas the PTC concentration ratio has positive correlation with the cavity open length. Increasing the tracking error angle and increasing the PTC focal distance would both decrease the cavity blackness. Introducing a flat plate reflector at the elliptical cavity open inlet can largely increase the cavity darkness.

  20. Evaluation of flat-plate collector efficiency under controlled conditions in a solar simulator

    Science.gov (United States)

    Johnson, S. M.; Simon, F. F.

    1976-01-01

    The measured thermal efficiencies of 35 collectors tested with a solar simulator, along with the correlation equations used to generalize the data, are presented in this report. The single correlation used is shown to apply to all the different types of collectors tested, including one with black paint and one cover, one with a selective surface coating and two covers, and an evacuated-tube collector. The test and correlation technique is also modified by using a shield so that collectors larger than the simulator test area can also be tested. This technique was verified experimentally for a shielded collector for which the collector shielded area was 31% of the solar simulator radiation area. A table lists all the collectors tested, the collector areas, and the experimental constants used to correlate the data for each collector.

  1. Efficiency and entropy generation in fined tube solar collectors systems; Eficiencia e geracao de entropia em sistemas de tubos aletados coletores de energia solar

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcio Bueno dos [Instituto Nacional de Pesquisas Espaciais (INPE), Sao Jose dos Campos, SP (Brazil). Lab. de Integracao e Testes; Saboya, Sergio Mourao [Instituto Tecnologico de Aeronautica, Sao Jose dos Campos, SP (Brazil). Dept. de Energia

    1998-07-01

    This paper studies the efficiency of a fined tube solar collector used in artificial satellites and the relation of this efficiency with the entropy generation in the fin. The mathematical modeling of heat transfer in the collector leads to a non-linear integrodifferential system of equations, which is solved numerically. The solution gives the efficiency, which is presented as function of geometrical and physical characteristics of the collector. It is also shown that a minimum entropy generation in the fins, in a collector, whose characteristics are subjected to constraints, corresponds to an optimum efficiency, that is, an efficiency value advantageous to collector performance. (author)

  2. Spiral multiple-effect diffusion solar still coupled with vacuum-tube collector and heat pipe

    KAUST Repository

    Huang, Bin-Juine

    2015-04-01

    © 2015 Elsevier B.V. A novel solar still with spiral-shape multiple-effect diffusion unit is developed in the present study. The test results of a 14-effect unit coupled with vacuum-tube solar collector (absorber area 1.08m2) show that the highest daily pure water production is 40.6kgd-1. The measured highest productivity based on the area of glass cover, solar absorber, and evaporating surface is 34.7, 40.6, and 7.96kgm-2d-1, respectively, which are much higher than the published results. The measured solar distillation efficiency is 2.0-3.5. The performance enhancement results mainly from the lateral diffusion process in the spiraled still cell. The vapor flow generated by heat input can flow freely and laterally through the spiral channel down to the end when solar heat input is high. Besides, the larger evaporating and condensing area at the outer cell may increase heat and mass transfer at the outer cell.

  3. Performance of solar collectors under low temperature conditions

    DEFF Research Database (Denmark)

    Bunea, Mircea; Eicher, Sara; Hildbrand, Catherine

    evaluated and results compared to experimental measurements. A mathematical model is also under development to include, in addition to the condensation phenomena, the frost, the rain and the long-wave radiation gains/losses on the rear of the solar collector. While the potential gain from rain was estimated......The performance of four solar thermal collectors (flat plate, evacuated tube, unglazed with rear insulation and unglazed without rear insulation) was experimentally measured and simulated for temperatures below ambient. The influence of several parameters (e.g. collector inlet temperature, air...

  4. Efficiency enhancement of octave-bandwidth traveling wave tubes by use of multistage depressed collectors

    Science.gov (United States)

    Ramins, P.; Fox, T. A.

    1979-01-01

    Small, three- and five-stage depressed collectors were evaluated in conjunction with a 4.8- to 9.6-GHz TWT of 325- to 675-W power output and a beam of 0.5 microperv. The multistage depressed collector (MDC) performed well even though its design had been optimized for a TWT of identical design but considerably less output power. Despite large, fixed losses significant efficiency enhancement was demonstrated with both the three- and five-stage depressed collectors. At saturated rf power output, the improvement in the overall efficiency ranged from a factor of 2.5 to 3.0 for the three-stage collector and a factor of 3.0 to 3.5 for the five-stage collector. At saturation three-stage collector efficiencies of 77 to 80 percent and five-stage collector efficiencies of 81 to 84 percent were obtained across the frequency band. An overall efficiency of 37.0 to 44.3 percent across the frequency band of 4.8 to 9.6 GHz was demonstrated with the use of harmonic injection. For operation below saturation, even larger relative improvements in the overall TWT efficiency were demonstrated. Collector performance was relatively insensitive to the degree of regulation of the collector power supply.

  5. Indoor test for thermal performance of the GE TC-100 liquid solar collector eight- and ten-tube configuration. [Marshall Space Flight Center solar simulator

    Science.gov (United States)

    1979-01-01

    The thermal performance of a liquid solar collector was tested in eight- and ten-tube configurations under simulated conditions. A time constant test and an incident angle modifier test were also conducted to determine the transient and incident angle effects on the collector. Performance loss with accessory covers is demonstrated. The gross collector area is about 17.4 ft sq without manifold and 19.1 ft sq with manifold. The collector weight is approximately 60 pounds empty and 75 pounds with manifold.

  6. Experimental Validation and Model Verification for a Novel Geometry ICPC Solar Collector

    DEFF Research Database (Denmark)

    Perers, Bengt; Duff, William S.; Daosukho, Jirachote

    A novel geometry ICPC solar collector was developed at the University of Chicago and Colorado State University. A ray tracing model has been designed to investigate the optical performance of both the horizontal and vertical fin versions of this collector. Solar radiation is modeled as discrete...... to the desired incident angle of the sun’s rays, performance of the novel ICPC solar collector at various specified angles along the transverse and longitudinal evacuated tube directions were experimentally determined. To validate the ray tracing model, transverse and longitudinal performance predictions...... at the corresponding specified incident angles are compared to the Sandia results. A 100 m2 336 Novel ICPC evacuated tube solar collector array has been in continuous operation at a demonstration project in Sacramento California since 1998. Data from the initial operation of the array are used to further validate...

  7. Traveling-wave-tube efficiency improvement by a low-cost technique for deposition of carbon on multistage depressed collector

    Science.gov (United States)

    Ebihara, Ben T.; Ramins, Peter; Peet, Shelly

    1987-01-01

    A simple method of improving the traveling-wave-tube (TWT) and multistage depressed collector (MDC) efficiency has been demonstrated. The efficiency improvement was produced by the application of a thin layer of carbon to the copper electrodes of the MDC by means of a rapid, low-cost technique involving the pyrolysis of hydrocarbon oil in electric arc discharges. Experimental results with a representative TWT and MDC showed an 11 percent improvement in both the TWT and MDC efficiencies as compared to those of the same TWT and MDC efficiencies with bare copper electrode surfaces. An extended test with a 500-W, continuous wave (CW) TWT and small-sized MDC indicated good stability of the carbon coated electrode surfaces after a relatively small initial degradation in TWT overall and apparent MDC efficiencies.

  8. Analisa Efisiensi Prototype Solar Collector Jenis Parabolic Trough dengan Menggunakan Cover Glass Tube pada Pipa Absorber

    Directory of Open Access Journals (Sweden)

    Hartamas Ridho Prasetyo

    2015-06-01

    Full Text Available Energi tidak dapat diciptakan maupun dimusnahkan, hanya dapat dikonversikan dari satu bentuk ke bentuk lainnya (Hukum Kekekalan Energi. Energi sangat penting dalam kehidupan sehari – hari khususnya energi listrik yang kebutuhan terhadap energi ini sangat besar sedangkan sebagian besar energi listrik dihasilkan dari sumber daya fosil yang mulai menipis jumlahnya. Ketergantungan akan minyak bumi untuk jangka panjang tidak dapat di pertahankan lebih lama jika pemakaian melebihi batas wajar. Dalam Tugas Akhir ini penulis melakukan analisa alat Parabolic Trough Solar Collector dengan memanfaatkan energi radiasi matahari, yang di awali adanya perancangan desain alat PTSC dengan material yang sudah di tentukan sebelumnya. Prototype tersebut hanya bisa dilakukan pengujian dengan posisi steady state atau diam antara jam 11.30 sampai dengan 12.30 siang. Dengan adanya penelitian tentang analisa performa pada alat tersebut, telah di dapatkan beberapa hasil nilai variabel yang signifikan dan berpengaruh besar dengan nilai performa alat tersebut.

  9. Preliminary design of an air solar collector

    Science.gov (United States)

    1979-01-01

    Report containing performance specifications and engineering drawings of concentric-tube air solar collector show details of collector and subcomponents that indicate efficiency surpassing predetermined performance baseline for air collectors.

  10. Extreme learning machine: a new alternative for measuring heat collection rate and heat loss coefficient of water-in-glass evacuated tube solar water heaters.

    Science.gov (United States)

    Liu, Zhijian; Li, Hao; Tang, Xindong; Zhang, Xinyu; Lin, Fan; Cheng, Kewei

    2016-01-01

    Heat collection rate and heat loss coefficient are crucial indicators for the evaluation of in service water-in-glass evacuated tube solar water heaters. However, the direct determination requires complex detection devices and a series of standard experiments, wasting too much time and manpower. To address this problem, we previously used artificial neural networks and support vector machine to develop precise knowledge-based models for predicting the heat collection rates and heat loss coefficients of water-in-glass evacuated tube solar water heaters, setting the properties measured by "portable test instruments" as the independent variables. A robust software for determination was also developed. However, in previous results, the prediction accuracy of heat loss coefficients can still be improved compared to those of heat collection rates. Also, in practical applications, even a small reduction in root mean square errors (RMSEs) can sometimes significantly improve the evaluation and business processes. As a further study, in this short report, we show that using a novel and fast machine learning algorithm-extreme learning machine can generate better predicted results for heat loss coefficient, which reduces the average RMSEs to 0.67 in testing.

  11. Effect of magnesium contamination in evacuated blood collection tubes on the prothrombin time test and ISI calibration using recombinant human thromboplastin and different types of coagulometer.

    Science.gov (United States)

    van den Besselaar, A M H P; Rutten, W P F; Witteveen, E

    2005-01-01

    The purpose of the present study was to assess the effect of two types of evacuated blood collection tube on the prothrombin time and international sensitivity index (ISI) of Recombiplastin, a recombinant human thromboplastin. Vacutainer tubes were compared with Venoject II tubes. Magnesium contamination was detected in the sodium citrate solutions contained in the Vacutainer tubes with concentrations ranging from 1.1 to 1.5 mmol/l. In contrast, magnesium ions could not be detected in the Venoject II tubes. The prothrombin ratio was decreased by contamination with magnesium ions and, hence, the ISI was increased. The magnitude of the effect of magnesium contamination on the ISI was influenced by the type of coagulometer and increased in the order: ACL Advance (3%), ACL-300 (4%), Electra-1000 (6%). The ISI bias is transmitted to the international normalized ratio (INR). In the case of the Electra-1000, the INR bias would be approximately 6% at INR 3.0 if the two types of blood collection tubes would be used without distinction. In a secondary study, the effect of magnesium contamination on the prothrombin time was assessed with the current World Health Organization international reference preparation for recombinant human thromboplastin (rTF/95). Magnesium chloride added to patients' blood (0.2 mmol/l) induced 2.3% reduction of the INR determined with rTF/95 and the manual technique. The magnitude of the influence of blood collection tubes contaminated with magnesium on ISI and INR determined with recombinant human thromboplastin depends on the coagulometer.

  12. Design and Testing of a Shell-Encapsulated Solar Collector with the Compound Surface Concentrators

    Directory of Open Access Journals (Sweden)

    Hongfei Zheng

    2015-01-01

    Full Text Available This paper presents design and testing of a shell-encapsulated solar collector which can be used in north area of China for wall-amounting installation. The designed solar collector is based on the combination of a novel compound curved surface concentrator and an aluminum concentric solar receiver, which is contained in a glass evacuated-tube. As there is no perforative joint between the double-skin glass evacuated-tube and the aluminum concentric solar receiver, the difficulty of vacuum keeping for a glass-metal joint is avoided. The cavity shell provides an additional thermal insulation to reduce heat loss of the designed solar collector. The working principle of the compound curved surface concentrator is described. The ray-tracing results are given to show the effect of deviation angle of the concentrator on its optical efficiency, hence determining its maximum acceptance angle. A prototype of the designed solar collector has been constructed and tested under the sunny winter weather condition. The experimental results indicate that the hot water temperature higher than 80°C with a daily average efficiency of about 45~50% has been achieved at the average ambient temperature below 0°C, so the designed solar collector can produce hot water at a useful temperature in winter.

  13. Biological sample collector

    Science.gov (United States)

    Murphy, Gloria A [French Camp, CA

    2010-09-07

    A biological sample collector is adapted to a collect several biological samples in a plurality of filter wells. A biological sample collector may comprise a manifold plate for mounting a filter plate thereon, the filter plate having a plurality of filter wells therein; a hollow slider for engaging and positioning a tube that slides therethrough; and a slide case within which the hollow slider travels to allow the tube to be aligned with a selected filter well of the plurality of filter wells, wherein when the tube is aligned with the selected filter well, the tube is pushed through the hollow slider and into the selected filter well to sealingly engage the selected filter well and to allow the tube to deposit a biological sample onto a filter in the bottom of the selected filter well. The biological sample collector may be portable.

  14. Evacuation exercise

    CERN Multimedia

    AUTHOR|(CDS)2094367

    2017-01-01

    In the event of an emergency, it is important that staff and visitors are evacuated safely and efficiently. Hence CERN organises regularly emergency response and evacuation exercise (also known as an ‘evacuation drill’) in different buildings across the sites.

  15. 3X compound parabolic concentrating (CPC) solar energy collector. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Ballheim, R.W.

    1980-04-25

    Chamberlain engineers designed a 3X compound parabolic concentrating (CPC) collector for the subject contract. The collector is a completely housed, 105.75 x 44.75 x 10.23-inch, 240-pound unit with six each evacuated receiver assemblies, a center manifold and a one-piece glass cover. A truncated version of a CPC trough reflector system and the General Electric Company tubular evacuated receiver have been integrated with a mass producible collector design suitable for operation at 250 to 450/sup 0/F. The key criterion for optimization of the design was minimization of the cost per Btu collected annually at an operating temperature of 400/sup 0/F. The reflector is a 4.1X design truncated to a total height of 8.0 inches with a resulting actual concentration ratio of 2.6 to 1. The manifold is an insulated area housing the fluid lines which connect the six receivers in series with inlet and outlet tubes extending from one side of the collector at the center. The reflectors are polished, anodized aluminum which are shaped by the roll form process. The housing is painted, galvanized steel, and the cover glass is 3/16-inch thick tempered, low iron glass. The collector requires four slope adjustments per year for optimum effectiveness. Chamberlain produced ten 3X CPC collectors for the subject contract. Two collectors were used to evaluate assembly procedures, six were sent to the project officer in Albuquerque, New Mexico, one was sent to Argonne National Laboratory for performance testing and one remained with the Company. A manufacturing cost study was conducted to estimate limited mass production costs, explore cost reduction ideas and define tooling requirements. The final effort discussed shows the preliminary design for application of a 3X CPC solar collector system for use in the Iowa State Capitol complex.

  16. Design package for concentrating solar collector panels

    Science.gov (United States)

    1978-01-01

    Information used to evaluate the design of the Northrup concentrating collector is presented. Included are the system performance specifications, the applications manual, and the detailed design drawings of the collector. The collector is a water/glycol/working fluid type, with a dipped galvanized steel housing, transparent acrylic Fresnel lens cover, copper absorber tube, and fiber glass insulation. It weights 98 pounds. A collector assembly includes four collector units within a tracking mount array.

  17. Solar collector with improved thermal concentration

    Science.gov (United States)

    Barak, Amitzur Z.

    1976-01-01

    Reduced heat loss from the absorbing surface of the energy receiver of a cylindrical radiant energy collector is achieved by providing individual, insulated, cooling tubes for adjacent parallel longitudinal segments of the receiver. Control means allow fluid for removing heat absorbed by the tubes to flow only in those tubes upon which energy is then being directed by the reflective wall of the collector.

  18. Internal absorber solar collector

    Science.gov (United States)

    Sletten, Carlyle J.; Herskovitz, Sheldon B.; Holt, F. S.; Sletten, E. J.

    1981-01-01

    Thin solar collecting panels are described made from arrays of small rod collectors consisting of a refracting dielectric rod lens with an absorber imbedded within it and a reflecting mirror coated on the back side of the dielectric rod. Non-tracking collector panels on vertical walls or roof tops receive approximately 90% of solar radiation within an acceptance zone 60.degree. in elevation angle by 120.degree. or more in the azimuth sectors with a collector concentration ratio of approximately 3.0. Miniaturized construction of the circular dielectric rods with internal absorbers reduces the weight per area of glass, plastic and metal used in the collector panels. No external parts or insulation are needed as heat losses are low due to partial vacuum or low conductivity gas surrounding heated portions of the collector. The miniature internal absorbers are generally made of solid copper with black selective surface and the collected solar heat is extracted at the collector ends by thermal conductivity along the absorber rods. Heat is removed from end fittings by use of liquid circulants. Several alternate constructions are provided for simplifying collector panel fabrication and for preventing the thermal expansion and contraction of the heated absorber or circulant tubes from damaging vacuum seals. In a modified version of the internal absorber collector, oil with temperature dependent viscosity is pumped through a segmented absorber which is now composed of closely spaced insulated metal tubes. In this way the circulant is automatically diverted through heated portions of the absorber giving higher collector concentration ratios than theoretically possible for an unsegmented absorber.

  19. Parabolic Trough Solar Collector Initial Trials

    Directory of Open Access Journals (Sweden)

    Ghalya Pikra

    2012-03-01

    Full Text Available This paper discusses initial trials of parabolic trough solar collector (PTSC in Bandung. PTSC model consists of concentrator, absorber and tracking system. Concentrator designs are made with 2m aperture width, 6m length and 0.75m focal distance. The design is equipped with an automatic tracking system which is driven using 12V and 24Watt DC motor with 0.0125rpm rotational speed. Absorber/receiver is designed with evacuated tube type, with 1 inch core diameter and tube made of AISI304 and coated with black oxide, the outer tube is borosilicate glass with a 70 mm diameter and 1.5 m length. Working fluid stored in single type of thermal storage tank, a single phase with 37.7 liter volume. PTSC model testing carried out for 2 hours and 10 minutes produces heat output and input of 11.5 kW and 0.64 kW respectively. 

  20. Design, fabrication, and performance of brazed, graphite electrode, multistage depressed collectors with 500-W, continuous wave, 4.8- to 9.6-GHz traveling-wave tubes

    Science.gov (United States)

    Ramins, Peter; Ebihara, Ben

    1989-03-01

    A small, isotropic graphite electrode, multistage depressed collector (MDC) was designed, fabricated, and evaluated in conjunction with a 500-W, continuous wave (CW), 4.8- to 9.6-GHz traveling-wave tube (TWT). The carbon electrode surfaces were used to improve the TWT overall efficiency by minimizing the secondary electron emission losses in the MDC. The design and fabrication of the brazed graphite MDC assembly are described. The brazing technique, which used copper braze filler metal, is compatible with both vacuum and the more commonly available hydrogen atmosphere brazing furnaces. The TWT and graphite electrode MCC bakeout, processing, and outgassing characteristics were evaluated and found to be comparable to TWT's equipped with copper electrode MDC's. The TWT and MDC performance was optimized for broadband CW operation at saturation. The average radiofrequency (RF), overall, and MDC efficiencies were 14.9, 46.4, and 83.6 percent, respectively, across the octave operating band. A 1500-hr CW test, conducted without the use of an appendage ion pump, showed no gas buildup and excellent stability of the electrode surfaces.

  1. The effect and contribution of wind generated rotation on outlet temperature and heat gain of LS-2 parabolic trough solar collector

    Directory of Open Access Journals (Sweden)

    Sadaghiyani Omid Karimi

    2013-01-01

    Full Text Available The Monte Carlo ray tracing method is applied and coupled with finite volume numerical methods to study effect of rotation on outlet temperature and heat gain of LS-2 parabolic trough concentrator (PTC. Based on effect of sunshape, curve of mirror and use of MCRT, heat flux distribution around of inner wall of evacuated tube is calculated. After calculation of heat flux, the geometry of LS-2 Luz collector is created and finite volume method is applied to simulate. The obtained results are compared with Dudley et al test results for irrotational cases to validate these numerical solving models. Consider that, for rotational models ,the solving method separately with K.S. Ball's results. In this work, according to the structure of mentioned collector, we use plug as a flow restriction. In the rotational case studies, the inner wall rotates with different angular speeds. We compare results of rotational collector with irrotational. Also for these two main states, the location of plug changed then outlet temperature and heat gain of collector are studied. The results show that rotation have positive role on heat transfer processing and the rotational plug in bottom half of tube have better effectual than upper half of tube. Also the contribution of rotation is calculated in the all of case studies. Working fluid of these study is one of the oil derivatives namely Syltherm-800. The power of wind can be used to rotate tube of collector.

  2. Solar Collectors

    Science.gov (United States)

    1980-01-01

    Solar Energy's solar panels are collectors for a solar energy system which provides heating for a drive-in bank in Akron, OH. Collectors were designed and manufactured by Solar Energy Products, a firm established by three former NASA employees. Company President, Frank Rom, an example of a personnel-type technology transfer, was a Research Director at Lewis Research Center, which conducts extensive solar heating and cooling research, including development and testing of high-efficiency flat-plate collectors. Rom acquired solar energy expertise which helped the company develop two types of collectors, one for use in domestic/commercial heating systems and the other for drying grain.

  3. Measuring the Optical Performance of Evacuated Receivers via an Outdoor Thermal Transient Test: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Kutscher, C.; Burkholder, F.; Netter, J.

    2011-08-01

    Modern parabolic trough solar collectors operated at high temperatures to provide the heat input to Rankine steam power cycles employ evacuated receiver tubes along the collector focal line. High performance is achieved via the use of a selective surface with a high absorptance for incoming short-wave solar radiation and a low emittance for outgoing long-wave infrared radiation, as well as the use of a hard vacuum to essentially eliminate convective and conductive heat losses. This paper describes a new method that determines receiver overall optical efficiency by exposing a fluid-filled, pre-cooled receiver to one sun outdoors and measuring the slope of the temperature curve at the point where the receiver temperature passes the glass envelope temperature (that is, the point at which there is no heat gain or loss from the absorber). This transient test method offers the potential advantages of simplicity, high accuracy, and the use of the actual solar spectrum.

  4. Study on the Instability of Two-Phase Flow in the Heat-Absorbing Tube of Trough Solar Collector

    Directory of Open Access Journals (Sweden)

    Ying Zhang

    2017-01-01

    Full Text Available The Marangoni effect and Rayleigh-Benard effect in the two-phase region of solar trough heat-absorbing tube are simulated by FTM (front tracking method. Considering the Marangoni effect alone, although surface tension gradient and surface tension affect the interface wave, the two effects have different characteristics. The surface tension gradient caused by the temperature gradient is one of the factors that swing the interface. The amplitude attenuation of the interface wave decreases with the increase of the Marangoni number (Ma. In general, the surface tension gradient enhances the convection opposite to the temperature gradient. Under the gravity field, the Rayleigh-Benard effect influences the development of the vortex structure in the flow field, which in turn affects the velocity gradient near the interface to influence the evolution of the interface fluctuation. In a small Rayleigh number (Ra, the buoyancy convection reduces the velocity gradient, thus suppressing the evolution of the interfacial wave. In the range of Ra  4.0E4, the situation is just the opposite. The larger the Ra is, the stronger the promoting effect is.

  5. Suction evacuation of hemothorax: A prospective study.

    Science.gov (United States)

    Savage, Stephanie A; Cibulas, George A; Ward, Tyler A; Davis, Corinne A; Croce, Martin A; Zarzaur, Ben L

    2016-07-01

    Although tube thoracostomy is a common procedure after thoracic trauma, incomplete evacuation of fluid places the patient at risk for retained hemothorax. As little as 300 to 500 cm of blood may result in the need for an additional thoracostomy tube or, in more severe cases, lung entrapment and empyema. We hypothesized that suction evacuation of the thoracic cavity before tube placement would decrease the incidence of late complications. Patients requiring tube thoracostomy within 96 hours of admission were prospectively identified and underwent suction evacuation of the pleural space (SEPS) before tube placement. These patients were compared to historical controls without suction evacuation. Demographics, admission vital signs, laboratory values, details of chest tube placement, and outcomes were collected on all patients. Multivariable logistic regression was used to compare outcomes between groups. A total of 199 patients were identified, consisting of 100 retrospective controls and 99 SEPS patients. There were no differences in age, sex, admission injury severity score or chest abbreviated injury score, admission laboratory values or vital signs, or hospital length of stay. Mean (SD) volume of hemothorax in SEPS patients was 220 (297) cm; with only 48% having a volume greater than 100 cm at the time of tube placement. Three patients developed empyema, and 19 demonstrated retained blood; there was no difference between SEPS and control patients. Suction evacuation of the pleural space was significantly protective against recurrent pneumothorax after chest tube removal (odds ratio, 0.332; 95% confidence interval, 0.148-0.745). Preemptive suction evacuation of the thoracic cavity did not have a significant impact on subsequent development of retained hemothorax or empyema. Suction evacuation of the pleural space significantly decreased incidence of recurrent pneumothorax after thoracostomy removal. Although the mechanism is unclear, such a benefit may make this

  6. How to select the best solar collector. Pt. 1. Comparative study of solar collector performance; Wo sich Spreu und Weizen trennen. T. 1. Kollektoren im energetischen Leistungsvergleich

    Energy Technology Data Exchange (ETDEWEB)

    Abrecht, S.; Kettner, C.; Meissner, R. [Paradigma Energie- und Umwelttechnik GmbH und Co.KG, Karlsbad (Germany)

    2008-06-15

    At higher operating temperatures, the results of solar collector with vacuum insulation differ from those with conventional thermal insulation, and tube collectors differ from flat plate collectors. In average insolation conditions (e.g. 450 W/m{sup 2}a at Wuerzburg), even the best flat plate collectors cannot compete with tube collectors at temperature gradients of 25 K and more from ambient temperature. From about 40 K, even the simplest tube collectors are better than flat plate collectors. These were the findings of internal studies carried out by Paradigma, a producer of solar systems. (orig.)

  7. Design review of a liquid solar collector

    Science.gov (United States)

    Wiesewmaier, B. L.

    1979-01-01

    Report documents procedures, results, and recommendations for in-depth analysis of problems with liquid-filled version of concentric-tube solar collector. Problems are related to loss of vacuum and/or violent fracture of collector elements, fluid leakage, freezing, flow anomalies, manifold damage, and other component failures.

  8. How to evaluate the influence of blood collection systems on the international sensitivity index. Protocol applied to two new evacuated tubes and eight coagulometer/thromboplastin combinations.

    Science.gov (United States)

    Tripodi, Armando; Chantarangkul, Veena; Bressi, Caterina; Mannucci, Pier Mannuccio

    2002-10-01

    Previous reports indicate that the international sensitivity index (ISI) of coagulometer/thromboplastin combinations (measuring systems) may be influenced by blood collection systems. We applied a new protocol to assess the extent with which two new blood collection systems (evaluation tubes) influence the ISI of eight widely used measuring systems. The evaluation tubes were made of plastic and had draw volumes of 1.8 and 2.7 ml; citrate concentration was 0.109 M. Well-established collection tubes (from the same manufacturer)-which were made of siliconized glass with draw volume and citrate concentration of 4.5 ml and 0.105 M, respectively-served as control. Plasmas from 20 healthy subjects and 60 patients on oral anticoagulants, collected with the evaluation and control tubes, were tested for prothrombin time (PT) with the eight measuring systems. Plasmas collected with the control tubes were also tested with an international standard for thromboplastin. Results were used to calculate the ISIs of the measuring systems. These were then used to calculate the differences of the crossover international normalized ratio (INR) (i.e., the INR obtained with PT ratios of plasmas collected into the evaluation tubes and the ISI determined with plasmas collected into the control tubes). Overall, the differences were small but measurable, especially for the 2.7-ml draw evaluation tubes and with some of the measuring systems (mean difference, tubes compare well with the control tubes from the same manufacturer. The protocol described here should be adopted for the evaluation of other blood collection systems.

  9. Solar collector

    Science.gov (United States)

    Wilhelm, William G.

    1982-01-01

    The field of this invention is solar collectors, and more particularly, the invention pertains to a flat plate collector that employs high performance thin films. The solar collector of this invention overcomes several problems in this field, such as excessive hardware, cost and reliability, and other prior art drawbacks outlined in the specification. In the preferred form, the apparatus features a substantially rigid planar frame (14). A thin film window (42) is bonded to one planar side of the frame. An absorber (24) of laminate construction is comprised of two thin film layers (24a, 24b) that are sealed perimetrically. The layers (24a, 24b) define a fluid-tight planar envelope (24c) of large surface area to volume through which a heat transfer fluid flows. Absorber (24) is bonded to the other planar side of the frame. The thin film construction of the absorber assures substantially full envelope wetting and thus good efficiency. The window and absorber films stress the frame adding to the overall strength of the collector.

  10. Modelisation, conception et simulation des performances d'un collecteur solaire aeraulique a tubes sous vide en milieu nordique

    Science.gov (United States)

    Paradis, Pierre-Luc

    The global energy consumption is still increasing year after year even if different initiatives are set up to decrease fossil fuel dependency. In Canada 80% of the energy is used for space heating and domestic hot water heating in residential sector. This heat could be provided by solar thermal technologies despite few difficulties originating from the cold climate. The aim of this project is to design a solar evacuated tube thermal collector using air as the working fluid. Firstly, needs and specifications of the product are established in a clear way. Then, three concepts of collector are presented. The first one relies on the standard evacuated tube. The second one uses a new technology of tubes; both sides are open. The third one uses heat pipe to extract the heat from the tubes. Based on the needs and specification as criteria, the concept involving tubes with both sides open has been selected as the best idea. In order to simulate the performances of the collector, a model of the heat exchanges in an evacuated tube was developed in 4 steps. The first step is a model in steady state intended to calculate the stagnation temperature of the tube for a fixed solar radiation, outside temperature and wind speed. As a second step, the model is generalised to transient condition in order to validate it with an experimental setup. A root mean square error of 2% is then calculated. The two remainder steps are intended to calculate the temperature of airflow leaving the tube. In the same way, a first model in steady state is developed and then generalised to the transient mode. Then, the validation with an experimental setup gave a difference of 0.2% for the root mean square error. Finally, a preindustrial prototype intended to work in open loop for preheating of fresh air is presented. During the project, explosion of the both sides open evacuated tube in overheating condition blocked the construction of a real prototype for the test. Different path for further work are

  11. Detailed Modeling of Flat Plate Solar Collector with Vacuum Glazing

    OpenAIRE

    Viacheslav Shemelin; Tomas Matuska

    2017-01-01

    A theoretical analysis of flat plate solar collectors with a vacuum glazing is presented. Different configurations of the collector have been investigated by a detailed theoretical model based on a combined external and internal energy balance of the absorber. Performance characteristics for vacuum flat plate collector alternatives have been derived. Subsequently, annual energy gains have been evaluated for a selected variant and compared with state-of-the-art vacuum tube collectors. The resu...

  12. Alternative to the cyclone. Vortex tube dust separator with integrated dust collector is economically efficient; Alternative zum Zyklon. Wirbelrohr-Staubabscheider mit integriertem Staubsammelbehaelter arbeitet wirtschaftlich

    Energy Technology Data Exchange (ETDEWEB)

    Sibbertsen, W. [Fachhochschule Hamburg (Germany). Physik

    2002-03-18

    Theoretical and numeric investigation of flow and energy separation in vortex tubes according to Ranque and Hilsch. Investigation of a vortex tube with a secondary stream on the hot gas side. Gas drying by the vortex tube process. Calculation of vortex tube characteristics according to Ranque-Hilsch with air, steam and refrigerant R22 as working fluids. [German] Theoretische Untersuchung und numerische Berechnung der Stroemung und Energietrennung im Wirbelrohr nach Ranque und Hilsch. Untersuchung eines Wirbelrohres mit warmgasseitigem Zusatzstrom. Gastrocknung mit dem Wirbelrohrverfahren. Ermittlung von Kennlinien eines Wirbelrohres nach Ranque-Hilsch mit den Arbeitsstoffen Luft, Wasserdampf und Kaeltemittel (R 22). (orig.)

  13. Evaluation of a Line-Concentrating Solar Collector

    Science.gov (United States)

    1982-01-01

    45-page report contains results of performance evaluation of line-concentrating solar collector. Collector employs parabolic trough to direct Sunlight to line along its focal axis, along which lies a black-chrome plated receiver tube covered by a glass tube containing still air. Reflective trough has aluminum-mirror surface covered with metallized acrylic film. Array of four collectors, positioned end to end was used for evaluation. Array was driven by single drive mechanism which was controlled by electronic tracking device.

  14. Hurricane Evacuation Routes

    Data.gov (United States)

    Department of Homeland Security — Hurricane Evacuation Routes in the United States A hurricane evacuation route is a designated route used to direct traffic inland in case of a hurricane threat. This...

  15. The PKI collector

    Science.gov (United States)

    Rice, M. P.

    1982-07-01

    The design and manufacturing of a solar thermal collector is discussed. The collector has three primary subsystems: concentrator, receiver/fluid loop, and controls. Identical curved reflective columns are utilized in a faceted Fresnel design to support 864 one foot square flat inexpensive second-surface, silvered glass mirrors. The columns are ganged together and rotated through their centers of gravity to provide elevation tracking. The concentrator is supported by a lightweight spaceframe structure which distributes all wind and gravity loads to the base supports. The base of the structure is a track which rotates on wheels mounted on concrete piers. A parallel tube steel heat exchanger is mounted at the concentrator focal area in a well insulated, galvanized steel housing. Two rows of vertical close-packed, staggered tubes connect a mud header and a steam header. Automatic two axis tracking and operational control is provided with a microprocessor based package. Concentrator-mounted shadowbands are the basis for active tracking. A software program provides azimuthal tracking during cloudy periods.

  16. Evacuation dynamics of children

    DEFF Research Database (Denmark)

    Larusdottir, Aldis Run; Dederichs, Anne

    2010-01-01

    The purpose of this study is to deliver new data and to bring attention to the subject of evacuation of children. Evacuation characteristics such as flow, densities and walking speeds are in focus. Currently literature on evacuation com-prehends mostly studies on adults. Ten Danish daycare centers...

  17. Evacuation of the ICU

    Science.gov (United States)

    Niven, Alexander S.; Beninati, William; Fang, Ray; Einav, Sharon; Rubinson, Lewis; Kissoon, Niranjan; Devereaux, Asha V.; Christian, Michael D.; Grissom, Colin K.; Christian, Michael D.; Devereaux, Asha V.; Dichter, Jeffrey R.; Kissoon, Niranjan; Rubinson, Lewis; Amundson, Dennis; Anderson, Michael R.; Balk, Robert; Barfield, Wanda D.; Bartz, Martha; Benditt, Josh; Beninati, William; Berkowitz, Kenneth A.; Daugherty Biddison, Lee; Braner, Dana; Branson, Richard D; Burkle, Frederick M.; Cairns, Bruce A.; Carr, Brendan G.; Courtney, Brooke; DeDecker, Lisa D.; De Jong, Marla J.; Dominguez-Cherit, Guillermo; Dries, David; Einav, Sharon; Erstad, Brian L.; Etienne, Mill; Fagbuyi, Daniel B.; Fang, Ray; Feldman, Henry; Garzon, Hernando; Geiling, James; Gomersall, Charles D.; Grissom, Colin K.; Hanfling, Dan; Hick, John L.; Hodge, James G.; Hupert, Nathaniel; Ingbar, David; Kanter, Robert K.; King, Mary A.; Kuhnley, Robert N.; Lawler, James; Leung, Sharon; Levy, Deborah A.; Lim, Matthew L.; Livinski, Alicia; Luyckx, Valerie; Marcozzi, David; Medina, Justine; Miramontes, David A.; Mutter, Ryan; Niven, Alexander S.; Penn, Matthew S.; Pepe, Paul E.; Powell, Tia; Prezant, David; Reed, Mary Jane; Rich, Preston; Rodriquez, Dario; Roxland, Beth E.; Sarani, Babak; Shah, Umair A.; Skippen, Peter; Sprung, Charles L.; Subbarao, Italo; Talmor, Daniel; Toner, Eric S.; Tosh, Pritish K.; Upperman, Jeffrey S.; Uyeki, Timothy M.; Weireter, Leonard J.; West, T. Eoin; Wilgis, John; Ornelas, Joe; McBride, Deborah; Reid, David; Baez, Amado; Baldisseri, Marie; Blumenstock, James S.; Cooper, Art; Ellender, Tim; Helminiak, Clare; Jimenez, Edgar; Krug, Steve; Lamana, Joe; Masur, Henry; Mathivha, L. Rudo; Osterholm, Michael T.; Reynolds, H. Neal; Sandrock, Christian; Sprecher, Armand; Tillyard, Andrew; White, Douglas; Wise, Robert; Yeskey, Kevin

    2014-01-01

    BACKGROUND: Despite the high risk for patient harm during unanticipated ICU evacuations, critical care providers receive little to no training on how to perform safe and effective ICU evacuations. We reviewed the pertinent published literature and offer suggestions for the critical care provider regarding ICU evacuation. The suggestions in this article are important for all who are involved in pandemics or disasters with multiple critically ill or injured patients, including front-line clinicians, hospital administrators, and public health or government officials. METHODS: The Evacuation and Mobilization topic panel used the American College of Chest Physicians (CHEST) Guidelines Oversight Committee’s methodology to develop seven key questions for which specific literature searches were conducted to identify studies upon which evidence-based recommendations could be made. No studies of sufficient quality were identified. Therefore, the panel developed expert opinion-based suggestions using a modified Delphi process. RESULTS: Based on current best evidence, we provide 13 suggestions outlining a systematic approach to prepare for and execute an effective ICU evacuation during a disaster. Interhospital and intrahospital collaboration and functional ICU communication are critical for success. Pre-event planning and preparation are required for a no-notice evacuation. A Critical Care Team Leader must be designated within the Hospital Incident Command System. A three-stage ICU Evacuation Timeline, including (1) no immediate threat, (2) evacuation threat, and (3) evacuation implementation, should be used. Detailed suggestions on ICU evacuation, including regional planning, evacuation drills, patient transport preparation and equipment, patient prioritization and distribution for evacuation, patient information and tracking, and federal and international evacuation assistance systems, are also provided. CONCLUSIONS: Successful ICU evacuation during a disaster requires

  18. Evacuated aerogel glazings

    DEFF Research Database (Denmark)

    Schultz, Jørgen Munthe; Jensen, Karsten Ingerslev

    2008-01-01

    This paper describes the main characteristics of monolithic silica aerogel and its application in evacuated superinsulating aerogel glazing including the evacuation and assembling process. Furthermore, the energetic benefit of aerogel glazing is quantified. In evacuated aerogel glazing the space ......) combined with a solar energy transmittance above 0.75.......This paper describes the main characteristics of monolithic silica aerogel and its application in evacuated superinsulating aerogel glazing including the evacuation and assembling process. Furthermore, the energetic benefit of aerogel glazing is quantified. In evacuated aerogel glazing the space...... between the glass panes is filled with monolithic silica aerogel evacuated to a rough vacuum of approximately 1-10 hPa. The aerogel glazing does not depend on use of low emissive coatings that have the drawback of absorbing a relatively large part of the solar radiation that otherwise could reduce...

  19. THEORETICAL STUDY OF SOLAR COLLECTOR WITH MINI PARABOLIC CONCENTRATOR

    Directory of Open Access Journals (Sweden)

    I TABET

    2013-12-01

    Full Text Available In this paper, numerical modeling and simulation of the thermal behavior of a solar collector vacuum tube with a concentration has been done, the value of adding a system of concentration at the back of the collector and try to increase the amount of solar radiation incident on the collector  in order to obtain high temperatures compared to traditional flat plate collector  and improved their energy performance, this type of collector  being integrated into buildings for domestic hot water, air conditioning and for cooling.

  20. Simple, economical solar collector

    Science.gov (United States)

    Anthony, K.

    1979-01-01

    Hot air solar collector designed for economy and simplicity is assembled from only three parts: (1) molded urethane foam body, (2) flat sheet metal collector panel and (3) transparent cover. Large arrays may be assembled by inserting male fittings of each collector into female fitting of adjacent collector.

  1. Selecting baghouse dust collectors

    Energy Technology Data Exchange (ETDEWEB)

    Moore, S.; Rubak, J.; Jolin, M. [Farr Co., El Segundo, CA (United States)]|[Farr Co., Laval, Quebec (Canada)

    1996-10-01

    Control of nuisance or process dusts generated within a plant is a vital concern with today`s growing emphasis on indoor air quality. In the past, many companies simply moved these contaminants away from workers and discharged them into the atmosphere. More stringent pollution control requirements now make this course of action unacceptable. Also, in some cases there is a need to recover high-value dusts, such as chemicals or precious metals. As a result, proper design and selection of a dust collection system are more critical than ever. There are two types of fabric filter dust collection systems commonly used today: baghouses and cartridges. Baghouses were the first collection systems with fabric media (in the form of long tubes, or bags) for removal of contaminants. The versatility of the baghouse--coupled with constant technological refinements--have made it a long-standing favorite among specifiers of pollution control equipment. In fact, baghouses account for more than 80% of all fabric filter dust collection systems in use today. Cartridge dust collectors use rigidly pleated filter elements instead of bags, making it possible to accommodate a large amount of filter surface area in a comparatively small package. Cartridge collectors also offer high efficiency and low pressure drop.

  2. Two new designs of parabolic solar collectors

    Directory of Open Access Journals (Sweden)

    Karimi Sadaghiyani Omid

    2014-01-01

    Full Text Available In this work, two new compound parabolic trough and dish solar collectors are presented with their working principles. First, the curves of mirrors are defined and the mathematical formulation as one analytical method is used to trace the sun rays and recognize the focus point. As a result of the ray tracing, the distribution of heat flux around the inner wall can be reached. Next, the heat fluxes are calculated versus several absorption coefficients. These heat flux distributions around absorber tube are functions of angle in polar coordinate system. Considering, the achieved heat flux distribution are used as a thermal boundary condition. After that, Finite Volume Methods (FVM are applied for simulation of absorber tube. The validation of solving method is done by comparing with Dudley's results at Sandia National Research Laboratory. Also, in order to have a good comparison between LS-2 and two new designed collectors, some of their parameters are considered equal with together. These parameters are consist of: the aperture area, the measures of tube geometry, the thermal properties of absorber tube, the working fluid, the solar radiation intensity and the mass flow rate of LS-2 collector are applied for simulation of the new presented collectors. After the validation of the used numerical models, this method is applied to simulation of the new designed models. Finally, the outlet results of new designed collector are compared with LS-2 classic collector. Obviously, the obtained results from the comparison show the improving of the new designed parabolic collectors efficiency. In the best case-study, the improving of efficiency are about 10% and 20% for linear and convoluted models respectively.

  3. Evacuation of Children

    DEFF Research Database (Denmark)

    Larusdottir, Aldis Run

    where needed, not leaving a boundary layer as the theory for adults suggests. Handrails were frequently used by both age groups in the daycare centers, more when walking on their own than when assisted. It was found that children using a low handrail achieved on average a 23.5% higher travel speed than......’s evacuation which is reflected in a rising number of publications on the topic. This thesis comprises evacuation experiments in daycares for children 0-6 years old and elementary schools for children aged 6-15 years. Full scale evacuations were filmed allowing detailed data analysis. Findings and results...

  4. Connectable solar air collectors

    Energy Technology Data Exchange (ETDEWEB)

    Oestergaard Jensen, S.; Bosanac, M.

    2002-02-01

    The project has proved that it is possible to manufacture solar air collector panels, which in an easy way can be connected into large collector arrays with integrated ducting without loss of efficiency. The developed connectable solar air collectors are based on the use of matrix absorbers in the form of perforated metal sheets. Three interconnected solar air collectors of the above type - each with an transparent area of approx. 3 m{sup 2} - was tested and compared with parallel tests on two single solar air collectors also with a transparent area of approx. 3 m{sup 2} One of the single solar air collectors has an identical absorber as the connectable solar air collectors while the absorber of the other single solar air collector was a fibre cloth. The efficiency of the three solar air collectors proved to be almost identical in the investigated range of mass flow rates and temperature differences. The solar air collectors further proved to be very efficient - as efficient as the second most efficient solar air collectors tested in the IEA task 19 project Solar Air Systems. Some problems remain although to be solved: the pressure drop across especially the connectable solar air collectors is too high - mainly across the inlets of the solar air collectors. It should, however, be possible to considerably reduce the pressure losses with a more aerodynamic design of the inlet and outlet of the solar air collectors; The connectable solar air collectors are easy connectable but the air tightness of the connections in the present form is not good enough. As leakage leads to lower efficiencies focus should be put on making the connections more air tight without loosing the easiness in connecting the solar air collectors. As a spin off of the project a simple and easy way to determine the efficiency of solar, air collectors for pre-heating of fresh air has been validated. The simple method of determining the efficiency has with success been compared with an advance method

  5. Surgical smoke evacuation systems.

    Science.gov (United States)

    1997-04-01

    Surgical smoke evacuation systems are high-flow vacuum sources used to capture, at the surgical site, the smoke aerosols and gases generated during the use of lasers and electrosurgical units (ESUs). In this study, we evaluated 16 evacuation systems, from 10 suppliers, designed and marketed for use in the operating room for general surgery. For our testing, we focused on the performance of the systems (particularly their ability to capture smoke particles under simulated surgical conditions) and their ease of use and quality of construction. We also examined the projected costs of each system over a seven-year life cycle. We rated the systems separately for two different evacuation applications (1) general-purpose applications, for which the system would, in many cases, be used with a handheld nozzle (the traditional capture device used with these systems), and (2) ESU-pencil-based evacuation applications only, for which the system would always be used with a pencil-based wand. (We report on ESU-pencil-based smoke evacuation wands in a separate Evaluation in this issue.) While we found most units to be Acceptable, we did rate two units Acceptable-Not Recommended for both applications and one unit Unacceptable for general-purpose applications. In addition to our findings for the evaluated models, this study features several sections providing generic information and guidance about smoke evacuation technology. The Technology Overview describes the basics: what these systems do and how they do it. The Technology Management Guide, "Clearing the Air-Should Surgical Smoke Be Evacuated?," discusses the issues healthcare facilities should consider when determining whether, when, and how surgical smoke should be evacuated. Finally, the Selection, Purchasing, and Use Guide offers guidance on how facilities can most effectively implement this technology, from identifying models that will meet their needs to ensuring that the systems are used properly to provide adequate staff

  6. Air/liquid collectors

    DEFF Research Database (Denmark)

    Jensen, Søren Østergaard; Olesen, Ole; Kristiansen, Finn Harken

    1997-01-01

    this kind of collectors. The modified simulation program has been used for the determination of the surplus in performance which solar heating systems with this type of solar collectors for combined preheating of ventilation air and domestic hot water will have. The simulation program and the efficiency......This report determine efficiency equations for combined air/liquid solar collectors by measurements on to different air/liquid collectors. Equations which contain all relevant informations on the solar collectors. A simulation program (Kviksol) has been modified in order to be able to handle...

  7. Detailed Modeling of Flat Plate Solar Collector with Vacuum Glazing

    Directory of Open Access Journals (Sweden)

    Viacheslav Shemelin

    2017-01-01

    Full Text Available A theoretical analysis of flat plate solar collectors with a vacuum glazing is presented. Different configurations of the collector have been investigated by a detailed theoretical model based on a combined external and internal energy balance of the absorber. Performance characteristics for vacuum flat plate collector alternatives have been derived. Subsequently, annual energy gains have been evaluated for a selected variant and compared with state-of-the-art vacuum tube collectors. The results of modeling indicate that, in the case of using advanced vacuum glazing with optimized low-emissivity coating (emissivity 0.20, solar transmittance 0.85, it is possible to achieve efficiency parameters similar to or even better than vacuum tube collectors. The design presented in this paper can be considered promising for the extension of the applicability range of FPC and could be used in applications, which require low-to-medium temperature level.

  8. Development of high efficiency collector plates. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Santala, T.; Sabol, R.

    1976-02-01

    Composite metal technology was used to manufacture intermetallic compound (IC) absorption surfaces and to combine them integrally with composite metal tube-in-sheet collector plates. Five material systems in which Al was one component metal and Fe, Cr, or Ni and their alloy was the other pair, were evaluated. All intermetallic compounds had high solar absorptance ..cap alpha.. approx. = 0.9. The AlNi was most promising and ..cap alpha.. > or = 0.95 and epsilon approx. = 0.3 were obtained over a broad range of compounding conditions. After eight months exposure in a flat plate collector enclosure the characteristic properties of AlNi surfaces remained virtually unchanged. Only LCS/Cu composite metal tube-in-sheet collector plates could be manufactured successfully. The technical difficulties associated with integrating the intermetallic compound and tube-in-sheet technologies make the manufacturing of composite metal collector plates at the time being economically unfeasible.

  9. Pulsed depressed collector

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, Mark A

    2015-11-03

    A high power RF device has an electron beam cavity, a modulator, and a circuit for feed-forward energy recovery from a multi-stage depressed collector to the modulator. The electron beam cavity include a cathode, an anode, and the multi-stage depressed collector, and the modulator is configured to provide pulses to the cathode. Voltages of the electrode stages of the multi-stage depressed collector are allowed to float as determined by fixed impedances seen by the electrode stages. The energy recovery circuit includes a storage capacitor that dynamically biases potentials of the electrode stages of the multi-stage depressed collector and provides recovered energy from the electrode stages of the multi-stage depressed collector to the modulator. The circuit may also include a step-down transformer, where the electrode stages of the multi-stage depressed collector are electrically connected to separate taps on the step-down transformer.

  10. Evacuation under limited visibility

    Science.gov (United States)

    Frank, Guillermo A.; Dorso, Claudio O.

    2015-06-01

    A multiplicity of situations can trigger off an evacuation of a room under panic conditions. For "normal" (with "normal" meaning absence of obstacles, perfect visibility, etc.) environmental conditions, the "faster is slower" effect dominates the dynamics of this process. It states that as the pedestrians desire to reach the exit increases, the clogging phenomena delays the time to get out of the room. But, environmental conditions are usually far from "normal." In this work, we consider that pedestrians have to find their way out under low visibility conditions. Some of them might switch to a herding-like behavior if they do not remember where the exit was. Others will just trust on their memory. Our investigation handles the herding and memory effects on the evacuation of a single exit room with no obstacles. We also include a section on how signaling devices affect the evacuation process. Unexpectedly, some low visibility situations may enhance the evacuation performance. This can be resumed as a second paradoxical result, since we demonstrated in an earlier investigation that "clever is not always better" G. A. Frank and C. O. Dorso, Physica A 390, 2135 (2011).

  11. Evacuation and Community Shelters

    Science.gov (United States)

    ... solution − Emergency preparedness kit − Clothing and bedding − Car keys If local officials haven’t advised an immediate evacuation, take these steps to protect your home before you leave: − Turn off electricity at the main fuse or breaker and turn ...

  12. Evacuation performance evaluation tool.

    Science.gov (United States)

    Farra, Sharon; Miller, Elaine T; Gneuhs, Matthew; Timm, Nathan; Li, Gengxin; Simon, Ashley; Brady, Whittney

    2016-01-01

    Hospitals conduct evacuation exercises to improve performance during emergency events. An essential aspect in this process is the creation of reliable and valid evaluation tools. The objective of this article is to describe the development and implications of a disaster evacuation performance tool that measures one portion of the very complex process of evacuation. Through the application of the Delphi technique and DeVellis's framework, disaster and neonatal experts provided input in developing this performance evaluation tool. Following development, content validity and reliability of this tool were assessed. Large pediatric hospital and medical center in the Midwest. The tool was pilot tested with an administrative, medical, and nursing leadership group and then implemented with a group of 68 healthcare workers during a disaster exercise of a neonatal intensive care unit (NICU). The tool has demonstrated high content validity with a scale validity index of 0.979 and inter-rater reliability G coefficient (0.984, 95% CI: 0.948-0.9952). The Delphi process based on the conceptual framework of DeVellis yielded a psychometrically sound evacuation performance evaluation tool for a NICU.

  13. Central Dental Evacuation Systems.

    Science.gov (United States)

    1982-05-01

    20 High-Vacuum Oral Evacuation System (HIVAC) for Oral Surgery, Periodontics, and Endodontics Treatment Rooms..................... 20...box-section steel rails. Rubber isolator pads between this frame and the structure floor absorb vibration and prevent its magnification . The inlet...System (HIVAC) for Oral Surgery, Periodontics, and Endodontics Treatment Rooms The HIVAC system is designed to build and sustain high vacuum pressures

  14. Evacuation drill at CMS

    CERN Multimedia

    Niels Dupont-Sagorin and Christoph Schaefer

    2012-01-01

    Training personnel, including evacuation guides and shifters, checking procedures, improving collaboration with the CERN Fire Brigade: the first real-life evacuation drill at CMS took place on Friday 3 February from 12p.m. to 3p.m. in the two caverns located at Point 5 of the LHC.   CERN personnel during the evacuation drill at CMS. Evacuation drills are required by law and have to be organized periodically in all areas of CERN, both above and below ground. The last drill at CMS, which took place in June 2007, revealed some desiderata, most notably the need for a public address system. With this equipment in place, it is now possible to broadcast audio messages from the CMS control room to the underground areas.   The CMS Technical Coordination Team and the GLIMOS have focused particularly on preparing collaborators for emergency situations by providing training and organizing regular safety drills with the HSE Unit and the CERN Fire Brigade. This Friday, the practical traini...

  15. All-glass solar collector

    Science.gov (United States)

    Wisnewski, J. P.

    1980-01-01

    Proposed all tempered glass solar collector uses black collection fluid and mirrored bottom to reduce energy loss and overall costs associated with conventional collectors. Collector is more efficient and practically maintenance-free.

  16. Solar collector overheating protection

    NARCIS (Netherlands)

    Slaman, M.J.; Griessen, R.P.

    Prismatic structures in a thermal solar collector are used as overheating protection. Such structures reflect incoming light efficiently back whenever less thermal power is extracted from the solar collector. Maximum thermal power is generated when the prismatic structure is surrounded by a

  17. Renewable Electricity Generation via Solar-Powered Methanol Reforming: Hybrid Proton Exchange Membrane Fuel Cell Systems Based on Novel Non-Concentrating, Intermediate-Temperature Solar Collectors

    Science.gov (United States)

    Real, Daniel J.

    Tremendous research efforts have been conducted studying the capturing and conversion of solar energy. Solar thermal power systems offer a compelling opportunity for renewable energy utilization with high efficiencies and excellent cost-effectiveness. The goal of this work was to design a non-concentrating collector capable of reaching temperatures above 250 °C, use this collector to power methanol steam reforming, and operate a proton exchange membrane (PEM) fuel cell using the generated hydrogen. The study presents the construction and characterization of a non-concentrating, intermediate-temperature, fin-in-tube evacuated solar collector, made of copper and capable of reaching stagnation temperatures of 268.5 °C at 1000 W/m2 irradiance. The collector was used to power methanol steam reforming, including the initial heating and vaporization of liquid reactants and the final heating of the gaseous reactants. A preferential oxidation (PROX) catalyst was used to remove CO from simulated reformate gas, and this product gas was used to operate a PEM fuel cell. The results show 1) that the outlet temperature is not limited by heat transfer from the absorber coating to the heat transfer fluid, but by the amount of solar energy absorbed. This implicates a constant heat flux description of the heat transfer process and allows for the usage of materials with lower thermal conductivity than copper. 2) It is possible to operate a PEM fuel cell from reformate gas if a PROX catalyst is used to remove CO from the gas. 3) The performance of the fuel cell is only slightly decreased (~4%) by CO2 dilution present in the reformate and PROX gas. These results provide a foundation for the first renewable electricity generation via solar-powered methanol reforming through a hybrid PEM fuel cell system based on novel non-concentrating, intermediate-temperature solar collectors.

  18. Fluid Line Evacuation and Freezing Experiments for Digital Radiator Concept

    Science.gov (United States)

    Berisford, Daniel F.; Birur, Gajanana C.; Miller, Jennifer R.; Sunada, Eric T.; Ganapathi, Gani B.; Stephan, Ryan; Johnson, Mark

    2011-01-01

    The digital radiator technology is one of three variable heat rejection technologies being investigated for future human-rated NASA missions. The digital radiator concept is based on a mechanically pumped fluid loop with parallel tubes carrying coolant to reject heat from the radiator surface. A series of valves actuate to start and stop fluid flow to di erent combinations of tubes, in order to vary the heat rejection capability of the radiator by a factor of 10 or more. When the flow in a particular leg is stopped, the fluid temperature drops and the fluid can freeze, causing damage or preventing flow from restarting. For this reason, the liquid in a stopped leg must be partially or fully evacuated upon shutdown. One of the challenges facing fluid evacuation from closed tubes arises from the vapor generated during pumping to low pressure, which can cause pump cavitation and incomplete evacuation. Here we present a series of laboratory experiments demonstrating fluid evacuation techniques to overcome these challenges by applying heat and pumping to partial vacuum. Also presented are results from qualitative testing of the freezing characteristics of several different candidate fluids, which demonstrate significant di erences in freezing properties, and give insight to the evacuation process.

  19. Behavior-based evacuation planning

    KAUST Repository

    Rodriguez, Samuel

    2010-05-01

    In this work, we present a formulation of an evacuation planning problem that is inspired by motion planning and describe an integrated behavioral agent-based and roadmap-based motion planning approach to solve it. Our formulation allows users to test the effect on evacuation of a number of different environmental factors. One of our main focuses is to provide a mechanism to investigate how the interaction between agents influences the resulting evacuation plans. Specifically, we explore how various types of control provided by a set of directing agents effects the overall evacuation planning strategies of the evacuating agents. ©2010 IEEE.

  20. Hybrid thermoelectric solar collector design and analysis

    Science.gov (United States)

    Roberts, A. S., Jr.; Shaheen, K. E.

    1982-01-01

    A flat-plate solar collector is conceived where energy cascades through thermoelectric power modules generating direct-current electricity. The intent of this work was to choose a collector configuration and to perform a steady-state thermal performance assessment. A set of energy balance equations were written and solved numerically for the purpose of optimizing collector thermal and electrical performance. The collector design involves finned columns of thermoelectric modules imbedded in the absorber plate (hot junction) over a parallel array of vertical tubes. The thermoelectric power output is limited by the small hot-junction/cold-junction temperature difference which can be maintained under steady-state conditions. The electric power per unit tube pass area is found to have a maximum as a function of a geometric parameter, while electric power is maximized with respect to an electric resistance ratio. Although the electric power efficiency is small, results indicate that there is sufficient electric power production to drive a coolant circulator, suggesting the potential for a stand-alone system.

  1. Heat Pumps With Direct Expansion Solar Collectors

    Science.gov (United States)

    Ito, Sadasuke

    In this paper, the studies of heat pump systems using solar collectors as the evaporators, which have been done so far by reserchers, are reviwed. Usually, a solar collector without any cover is preferable to one with ac over because of the necessity of absorbing heat from the ambient air when the intensity of the solar energy on the collector is not enough. The performance of the collector depends on its area and the intensity of the convective heat transfer on the surface. Fins are fixed on the backside of the collector-surface or on the tube in which the refrigerant flows in order to increase the convective heat transfer. For the purpose of using a heat pump efficiently throughout year, a compressor with variable capacity is applied. The solar assisted heat pump can be used for air conditioning at night during the summer. Only a few groups of people have studied cooling by using solar assisted heat pump systems. In Japan, a kind of system for hot water supply has been produced commercially in a company and a kind of system for air conditioning has been installed in buildings commercially by another company.

  2. FLOW DISTRIBUTION IN A SOLAR COLLECTOR PANEL WITH HORIZONTAL ABSORBER STRIPS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    2007-01-01

    The objective of this work is to theoretically and experimentally investigate the flow and temperature distribution in a solar collector panel with an absorber consisting of horizontal strips. Fluid flow and heat transfer in the collector panel are studied by means of computational fluid dynamics...... (CFD) calculations. Further, experimental investigations of a 12.5 m² solar collector panel with 16 parallel connected horizontal fins are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the backside of the absorber tubes. The measured...... collector fluid, and by increased collector tilt and inlet temperature, the flow distribution gets worse resulting in a decreased collector efficiency and an increased risk of boiling in the upper part of the collector panel. Keywords: Solar collector; Flow distribution; Computational Fluid Dynamics (CFD...

  3. Theoretical study of fluidized solar collector performance

    Energy Technology Data Exchange (ETDEWEB)

    Adulla, S. H; Kassem, M A; El-Refaie, M. F. [Cairo University, Giza (Egypt)

    2000-07-01

    This work presents a proposed novel design aiming to increasing the absorber-to-fluid heat transfer coefficient. This is accomplished by introducing small solid particles inside the collector tubes. When the collector liquid flows, it causes the particles to be fluidized and spread in the tubes. The particles material, size and total number should be turned together with the fluid mass flow rate to keep the bed, or particle dispersion, length within the physical length of collector tubes. Thus, the particles would be confined in the collector only; and not carried over to other parts of the circulation loop. While moving, the particles erode the thermal boundary layer formed on the tube inner surface, hence increasing the heat transfer coefficient. [Spanish] Este articulo presenta un diseno novedoso destinado a aumentar el coeficiente de trasferencia de calor de absorbedor a fluido. Esto se lleva a cabo mediante la introduccion de particulas solidas dentro de los tubos del colector. Cuando fluye el liquido del colector origina que las particulas se fluidicen y se diseminen en los tubos. El material de las particulas, tamano y numero total debera de ser puesto en movimiento junto con el regimen de flujo de masa de fluido para mantener el lecho o la dispersion de particulas por largo tiempo dentro de la longitud fisica de los tubos de colector. De esta manera las particulas seran confinadas solamente en el colector y no seran arrastradas a otras partes del anillo de circulacion. Al moverse, las particulas erosionan la capa de frontera termica formada en la superficie interior del tubo, aumentando por tanto el coeficiente de transmision de calor.

  4. FLOW DISTRIBUTION IN A SOLAR COLLECTOR PANEL WITH HORIZONTAL FINS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    2005-01-01

    The objective of this work is to theoretically and experimentally investigate the flow and temperature distribution in a solar collector panel with an absorber consisting of horizontal fins. Fluid flow and heat transfer in the collector panel are studied by means of computational fluid dynamics...... (CFD) calculations. Further, experimental investigations of a 12.5 m² solar collector panel with 16 parallel connected horizontal fins are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the backside of the absorber tubes. The measured...

  5. Analysis of a high-performance tubular solar collector

    Science.gov (United States)

    Lansing, F. L.; Yung, C. S.

    1981-01-01

    This article analyzes the thermal performance of a new vacuum tube solar collector. The assumptions and mathematical modeling are presented. The problem is reduced to the formulation of two simultaneous linear differential equations characterizing the collector thermal behavior. After applying the boundary conditions, a general solution is obtained which is found similar to the general Hottel, Whillier and Bliss form, but with a complex flow factor. The details of the two-dimensional thermal model of the solar collector at steady state is also presented to include the computer simulation and the performance parameterization. Comparison of the simulated performance with the manufacturer's test data showed good agreement at wide ranges of operating conditions.

  6. Analysis of WWER 1000 collector cracking mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Matocha, K.; Wozniak, J. [Vitkovice J.S.C., Ostrava (Switzerland)

    1997-12-31

    The presentation reviews the large experimental program, started in 1993 in Vitkovice, where the main aim was: (1) a detailed study of strain and thermal ageing, dissolved oxygen content and temperature on subcritical crack growth in 10NiMo8.5 (10GN2MFA) steel, (2) a detailed study of the effect of high temperature water and tube expansion technology on fracture behaviour of ligaments between holes for heat exchange tubes, and (3) a detailed study of the effect of drilling, tube expansion technology and heat treatment on residual stresses on the surface of holes for heat exchange tubes. The aim of all these investigations was to find a dominant damage mechanism responsible for collector cracking to be able to judge the efficiency of implemented modifications and suggested countermeasures and to answer a very important question whether proper operation conditions (mainly water chemistry) make the operation of steam generators made in Vitcovice safe throughout the planned lifetime. 10 refs.

  7. Theoretical analysis to investigate thermal performance of co-axial heat pipe solar collector

    Science.gov (United States)

    Azad, E.

    2011-12-01

    The thermal performance of co-axial heat pipe solar collector which consist of a collector 15 co-axial heat pipes surrounded by a transparent envelope and which heat a fluid flowing through the condenser tubes have been predicted using heat transfer analytical methods. The analysis considers conductive and convective losses and energy transferred to a fluid flowing through the collector condenser tubes. The thermal performances of co-axial heat pipe solar collector is developed and are used to determine the collector efficiency, which is defined as the ratio of heat taken from the water flowing in the condenser tube and the solar radiation striking the collector absorber. The theoretical water outlet temperature and efficiency are compared with experimental results and it shows good agreement between them. The main advantage of this collector is that inclination of collector does not have influence on performance of co-axial heat pipe solar collector therefore it can be positioned at any angle from horizontal to vertical. In high building where the roof area is not enough the co-axial heat pipe solar collectors can be installed on the roof as well as wall of the building. The other advantage is each heat pipe can be topologically disconnected from the manifold.

  8. Tracking system for solar collectors

    Science.gov (United States)

    Butler, B.

    1980-10-01

    A tracking system is provided for pivotally mounted spaced-apart solar collectors. A pair of cables is connected to spaced-apart portions of each collector, and a driver displaces the cables, thereby causing the collectors to pivot about their mounting, so as to assume the desired orientation. The collectors may be of the cylindrical type as well as the flat-plate type. Rigid spar-like linkages may be substituted for the cables. Releasable attachments of the cables to the collectors is also described, as is a fine tuning mechanism for precisely aligning each individual collector.

  9. Tracking system for solar collectors

    Science.gov (United States)

    Butler, Barry L.

    1984-01-01

    A tracking system is provided for pivotally mounted spaced-apart solar collectors. A pair of cables is connected to spaced-apart portions of each collector, and a driver displaces the cables, thereby causing the collectors to pivot about their mounting, so as to assume the desired orientation. The collectors may be of the cylindrical type as well as the flat-plate type. Rigid spar-like linkages may be substituted for the cables. Releasable attachments of the cables to the collectors is also described, as is a fine tuning mechanism for precisely aligning each individual collector.

  10. Evacuation from a Complex Structure

    DEFF Research Database (Denmark)

    Sørensen, Janne Gress; Dederichs, Anne

    2014-01-01

    How is the total evacuation time of a mixed population and its subgroups predicted by the evacuation tool STEPS? Simulation using STEPS is compared with experimental data and evaluated based on individual total egress times. It was found that the total egress times were similar for the simulation...

  11. Ventilation Criteria for Aeromedical Evacuation.

    Science.gov (United States)

    1986-09-01

    number) FIELD GROUP i SUB-GROUP Aeromedical evacuation; Ventilatory requirements; 06 11 06 12 iAir evacuation; and Mechanical ventilation . 19...ABSTRACT (Continue on reverse if necessary and identify by block number) -., fr evacLation of patients requiring mechanical ventilation exposes these...reasonably stable from a medical standpoint; none required mechanical ventilation . Unfortunately, we find no .- , studies that describe the

  12. Societal acceptance of unnecessary evacuation

    Science.gov (United States)

    McCaughey, Jamie W.; Mundzir, Ibnu; Patt, Anthony; Rosemary, Rizanna; Safrina, Lely; Mahdi, Saiful; Daly, Patrick

    2017-04-01

    Uncertainties in forecasting extreme events force an unavoidable tradeoff between false alarms and misses. The appropriate balance depends on the level of societal acceptance of unnecessary evacuations, but there has been little empirical research on this. Intuitively it may seem that an unnecessary evacuation would make people less likely to evacuate again in the future, but our study finds no support for this intuition. Using new quantitative (n=800) and qualitative evidence, we examine individual- and household-level evacuation decisions in response to the strong 11-Apr-2012 earthquake in Aceh, Indonesia. This earthquake did not produce a tsunami, but the population had previously experienced the devastating 2004 tsunami. In our sample, the vast majority of people (86%) evacuated in the 2012 earthquake, and nearly all (94%) say they would evacuate again if a similar earthquake happened in the future. Self-reported level of fear at the moment of the 2012 earthquake explains more of the variance in evacuation decisions and intentions than does a combination of perceived tsunami risk and perceived efficacy of evacuation modeled on protection motivation theory. These findings suggest that the appropriate balance between false alarms and misses may be highly context-specific. Investigating this in each context would make an important contribution to the effectiveness of early-warning systems.

  13. The Experimental Performance of an Unglazed PVT Collector with Two Different Absorber Types

    Directory of Open Access Journals (Sweden)

    Jin-Hee Kim

    2012-01-01

    Full Text Available Photovoltaic-thermal collectors combine photovoltaic modules and solar thermal collectors, forming a single device that produces electricity and heat simultaneously. There are two types of liquid-type PVT collectors, depending on the existence or absence of a glass cover over the PV module. The glass-covered (glazed PVT collector produces relatively more thermal energy but has a lower electrical yield, whereas the uncovered (unglazed PVT collector has a relatively low thermal energy and somewhat higher electrical performance. The thermal and electrical performance of liquid-type PVT collectors is related not only to the collector design, such as whether a glass cover is used, but also to the absorber design, that is, whether the absorber is for the sheet-and-tube type or the fully wetted type. The design of the absorber, as it comes into contact with the PV modules and the liquid tubes, is regarded as important, as it is related to the heat transfer from the PV modules to the liquid in the tubes. In this paper, the experimental performance of two liquid-type PVT collectors, a sheet-and-tube type and a fully wetted type, was analyzed.

  14. Evacuation modeling trends

    CERN Document Server

    Abreu, Orlando; Alvear, Daniel

    2016-01-01

    This book presents an overview of modeling definitions and concepts, theory on human behavior and human performance data, available tools and simulation approaches, model development, and application and validation methods. It considers the data and research efforts needed to develop and incorporate functions for the different parameters into comprehensive escape and evacuation simulations, with a number of examples illustrating different aspects and approaches. After an overview of basic modeling approaches, the book discusses benefits and challenges of current techniques. The representation of evacuees is a central issue, including human behavior and the proper implementation of representational tools. Key topics include the nature and importance of the different parameters involved in ASET and RSET and the interactions between them. A review of the current literature on verification and validation methods is provided, with a set of recommended verification tests and examples of validation tests. The book c...

  15. Black Liquid Solar Collector Demonstrator.

    Science.gov (United States)

    Weichman, F. L.; Austen, D. J.

    1979-01-01

    Describes the details of constructing, and use of, a solar collector. Uses a black liquid to absorb the energy, the thermosyphon effect to drive the liquid through the collector, and a floodlamp as a surrogate sun. (GA)

  16. Comparing solar collectors - where the wheat separates from the chaff; Kollektorvergleiche. Wo sich Spreu und Weizen trennen

    Energy Technology Data Exchange (ETDEWEB)

    Abrecht, S.; Griesshaber, W.; Kettner, C.; Meissner, R. [Paradigma GmbH, Karlsbad (Germany)

    2008-12-15

    Solar plants are an important option among climate-friendly energy technologies. However, a closer look at collector technologies available on the market reveals dramatic differences. At high operating temperatures the performance of solar collectors with vacuum insulation stands out clearly against collectors with conventional insulation. Under average or above-average solar radiation conditions with temperature differences relative to ambient levels of 25 K and more not even the best flat-panel collectors can compete technically with tube collectors. The following article shows that only high-performance vacuum tube collectors can cover the requirements of applications involving large-scale process heat. This should have consequences for the allocation of state funds to different collector technologies.

  17. Development, testing, and certification of Calmac Mfg. Corp. solar collector and solar operated pump

    Science.gov (United States)

    Parker, J. C.

    1979-01-01

    Development of a rubber tube solar collector and solar operated pump for use with solar heating and cooling systems is discussed. The development hardware, problems encountered during fabrication and testing, and certification statements of performance are included.

  18. Solar energy collector

    Science.gov (United States)

    Brin, Raymond L.; Pace, Thomas L.

    1978-01-01

    The invention relates to a solar energy collector comprising solar energy absorbing material within chamber having a transparent wall, solar energy being transmitted through the transparent wall, and efficiently absorbed by the absorbing material, for transfer to a heat transfer fluid. The solar energy absorbing material, of generally foraminous nature, absorbs and transmits the solar energy with improved efficiency.

  19. Leaves: Nature's Solar Collectors

    Science.gov (United States)

    Isabelle, Aaron D.; de Groot, Cornelis

    2009-01-01

    One of the most captivating things about plants is the way they capture the Sun's energy, but this can be a difficult topic to cover with elementary students. Therefore, to help students to make a concrete connection to this abstract concept, this series of solar-energy lessons focuses on leaves and how they act as "solar collectors." As students…

  20. Liquid solar collector

    Science.gov (United States)

    1980-01-01

    Report documents evaluation test on commercial flat-plate solar collector that uses water as working fluid. Performance was measured before and after 34-day exposure to natural environment. Tables in metric and English units present data on air and water temperatures, waterflow, insolation, efficiency, and windspeed and direction.

  1. Structurally integrated steel solar collector

    Science.gov (United States)

    Moore, Stanley W.

    1977-03-08

    Herein is disclosed a flat plate solar heat collector unit. The solar collector is integrated as a structural unit so that the collector also functions as the building roof. The functions of efficient heat collection, liquid coolant flow passages, roof structural support and building insulation are combined into one unit.

  2. Colored solar collectors - Annual report 2006

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, A.; Chambrier, E. De; Roecker, Ch.; Scartezzini, J.-L.

    2007-12-15

    The architectural integration of thermal solar collectors into buildings is often limited by their black color, and the visibility of tubes and corrugations of the absorber sheets. A certain freedom in color choice would be desirable, but the colored appearance should not cause an excessive degradation of the collector efficiency. Multilayered thin film interference filters on the collector glazing can produce a colored reflection, hiding the corrugated metal sheet, while transmitting the non-reflected radiation entirely to the absorber. These interference filters are designed and optimized by numerical simulation, and are manufactured by sol-gel dip-coating or magnetron sputtering. The novel colored glazed solar collectors will be ideally suited for architectural integration into buildings, e.g. as solar active glass facades. Due to the tunability of the refractive index, nanostructured materials such as SiO{sub 2}:TiO{sub 2} composites and porous SiO{sub 2} are very useful for application in multilayer interference stacks. Novel quaternary Mg-F-Si-O films exhibit a surprisingly low refractive index and are therefore promising candidates for highly transparent coatings on solar collector glazing. The nanostructure of these thin films is studied by transmission electron microscopy, while the optical constants are measured precisely by ellipsometry. For a convincing demonstration, sufficiently large samples of high quality are imperatively needed. The fabrication of nanocomposite SiO{sub 2}:TiO{sub 2} films has been demonstrated by sol-gel dip-coating of A4-sized glass panes. The produced coatings exhibit a colored reflection in combination with a high solar transmittance, a homogenous appearance, and are free of visible defects. Film hardening by UV exposure will result in speeding up the sol-gel process and saving energy, thereby reducing costs significantly. The infrastructure for UV-curing has been established. A UV C radiation source can now be attached to the

  3. Improved Large Aperture Collector Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    O' Rourke, Deven [Abengoa Solar LLC, Lakewood, CO (United States); Farr, Adrian [Abengoa Solar LLC, Lakewood, CO (United States)

    2015-12-01

    The parabolic trough is the most established CSP technology and carries a long history of design experimentation dating back to the 1970’s. This has led to relatively standardized collector architectures, a maturing global supply chain, and a fairly uniform cost reduction strategy. Abengoa has deployed more than 1,500MWe of CSP troughs across several countries and has built and tested full-scale prototypes of many R&D concepts. The latest trough R&D efforts involved efforts to internalize non-CSP industry experience including a preliminary DFMA principles review done with Boothroyd Dewhurst, a construction literature review by the Arizona State University School of Construction Management, and two more focused manufacturing engineering subcontracts done by Ricardo Inc. and the nonprofit Edison Welding Institute. The first two studies highlighted strong opportunities in lowering part count, standardizing components and fasteners, developing modular designs to support prefabrication and automation, and devising simple, error-proof manual assembly methods. These principles have delivered major new cost savings in otherwise “mature” products in analogous industries like automotive, truck trailer manufacture, metal building fabrication, and shipbuilding. For this reason, they were core in the design development of the SpaceTube® collector, and arguably key to its early successes. The latter two studies were applied specifically to the first-generation SpaceTube® design and were important in setting the direction of the present SolarMat project. These studies developed a methodology to analyze the costs of manufacture and assembly, and identify new tooling concepts for more efficient manufacture. Among the main opportunities identified in these studies were the automated mirror arm manufacturing concept and the need for a less infrastructure-intensive assembly line, both of which now form central pillars of the SolarMat project strategy. These new designs will be

  4. CMS DT Upgrade The Sector Collector Relocation

    CERN Document Server

    AUTHOR|(CDS)2079704

    2016-01-01

    The Sector Collector relocation is the first stage of the upgrade program for the Drift Tubes subdetector of the CMS experiment. It was accomplished during Long Shutdown 2013-2014, and consisted in the relocation of the second-level trigger and readout electronics from the experimental to the service cavern, relieving the environmental constraints and improving accessibility for maintenance and upgrade. Extending the electrical links would degrade reliability, so the information is converted to optical with a custom system capable of dealing with the DC-unbalanced data. Initially, present electronics are used, so optical-to-copper conversion has also been installed.

  5. Solar collector array

    Science.gov (United States)

    Hall, John Champlin; Martins, Guy Lawrence

    2015-09-06

    A method and apparatus for efficient manufacture, assembly and production of solar energy. In one aspect, the apparatus may include a number of modular solar receiver assemblies that may be separately manufactured, assembled and individually inserted into a solar collector array housing shaped to receive a plurality of solar receivers. The housing may include optical elements for focusing light onto the individual receivers, and a circuit for electrically connecting the solar receivers.

  6. Flow distribution in a solar collector panel with horizontally inclined absorber strips

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    2007-01-01

    The objective of this work is to theoretically and experimentally investigate the flow and temperature distribution in a solar collector panel with an absorber consisting of horizontally inclined strips. Fluid flow and heat transfer in the collector panel are studied by means of computational fluid...... dynamics (CFD) calculations. Further, experimental investigations of a 12.5 m(2) solar collector panel with 16 parallel connected horizontal fins are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the backside of the absorber tubes. The measured...... rate, properties of solar collector fluid, solar collector fluid inlet temperature and collector tilt angle are shown. The flow distribution through the absorber fins is uniform if high flow rates are used. By decreased flow rate and decreased content of glycol in the glycol/water mixture used as solar...

  7. Turning collectors for solar radiation

    Science.gov (United States)

    Barak, Amitzur Z.

    1976-01-01

    A device is provided for turning a solar collector about the polar axis so that the collector is directed toward the sun as the sun tracks the sky each day. It includes two heat-expansive elements and a shadow plate. In the morning a first expansive element is heated, expands to turn the collector to face the sun, while the second expansive element is shaded by the plate. In the afternoon the second element is heated, expands to turn the collector to face the sun, while the first is shaded by the plate.

  8. Concentrating solar collector - final design

    Science.gov (United States)

    Parker, J. C.

    1980-01-01

    Final report of program to improve commercially available concentrating solar collector describes final hardware, discusses problems encountered, and presents certification statements, photographs, and recommendations for modification.

  9. City evacuations an interdisciplinary approach

    CERN Document Server

    Binner, Jane; Branicki, Layla; Galla, Tobias; Jones, Nick; King, James; Kolokitha, Magdalini; Smyrnakis, Michalis

    2015-01-01

    Evacuating a city is a complex problem that involves issues of governance, preparedness education, warning, information sharing, population dynamics, resilience and recovery. As natural and anthropogenic threats to cities grow, it is an increasingly pressing problem for policy makers and practitioners.   The book is the result of a unique interdisciplinary collaboration between researchers in the physical and social sciences to consider how an interdisciplinary approach can help plan for large scale evacuations.  It draws on perspectives from physics, mathematics, organisation theory, economics, sociology and education.  Importantly it goes beyond disciplinary boundaries and considers how interdisciplinary methods are necessary to approach a complex problem involving human actors and increasingly complex communications and transportation infrastructures.   Using real world case studies and modelling the book considers new approaches to evacuation dynamics.  It addresses questions of complexity, not only ...

  10. Integrated solar collector

    Science.gov (United States)

    Tchernev, Dimiter I.

    1985-01-01

    A solar collector having a copper panel in a contiguous space relationship with a condenser-evaporator heat exchanger located under the panel, the panel having a honeycomb-like structure on its interior defining individual cells which are filled with zeolite loaded, in its adsorbed condition, with 18 to 20% by weight of water. The interior of the panel and heat exchanger are maintained at subatmospheric pressure of about 0.1 to 1 psia. The panel and heat exchanger are insulated on their lateral sides and bottoms and on the top of the heat exchange. The panel has a black coating on its top which is exposed to and absorbs solar energy. Surrounding the insulation (which supports the panel) is an extruded aluminum framework which supports a pair of spaced-apart glass panels above the solar panel. Water in conduits from a system for heating or cooling or both is connected to flow into an inlet and discharge from outlet of a finned coil received within the heat exchanger. The collector panel provides heat during the day through desorption and condensing of water vapor from the heated solar panel in the heat exchanger and cools at night by the re-adsorption of the water vapor from the heat exchanger which lowers the absolute pressure within the system and cools the heat exchange coils by evaporation.

  11. Evacuation transportation management. Task five, Operational concept

    Science.gov (United States)

    2006-01-01

    Much of what is known about evacuations is based on preparations for incidents, such as hurricanes, for which there is advance warning. With advance warning, evacuations can be planned and managed using procedures and systems that have been developed...

  12. Evacuation transportation management : task five : operational concept.

    Science.gov (United States)

    2009-06-26

    Much of what is known about evacuations is based on preparations for incidents, such as hurricanes, for which there is advance warning. With advance warning, evacuations can be planned and managed using procedures and systems that have been developed...

  13. Evacuation Shelters - MDC_HurricaneShelter

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — A label feature class of Miami-Dade County Hurricane Evacuation Shelters (HEC) including Special Need Evacuation Centers (SNEC) and Medical Management Facilities...

  14. An Integrated Approach to Modeling Evacuation Behavior

    Science.gov (United States)

    2011-02-01

    A spate of recent hurricanes and other natural disasters have drawn a lot of attention to the evacuation decision of individuals. Here we focus on evacuation models that incorporate two economic phenomena that seem to be increasingly important in exp...

  15. Chemical Agents: Facts about Evacuation

    Science.gov (United States)

    ... with Chronic Illnesses Glucose Monitoring at Evacuation Centers Dialysis Care After a Disaster Evacuees Keep It With You Drug and Medical Device Safety Immunizations Food & Water Safety and Hand Hygiene Clean Hands Save Lives Resources for Emergency Health Professionals Clinician Outreach and ...

  16. Effectiveness of Installation Aeromedical Evacuation

    Science.gov (United States)

    2013-12-13

    Aeromedical Evacuation Approved by: , Thesis Committee Chair Jackie D. Kem, Ph.D , Member Larry J. Lust, M.S...David Brown, Lawrence V. Fulton, Robert Mitchell, Wayne Pollard, Mark Robinson , and Ronald Wilson. 2013. Analyzing the future of Army aeromedical

  17. NUMERICAL SIMULATION OF THE AIR FLOW AROUND THE ARRAYS OF SOLAR COLLECTORS

    Directory of Open Access Journals (Sweden)

    Vukman V Bakić

    2011-01-01

    Full Text Available This paper deals with the numerical simulation of air around the arrays of flat plate collectors and determination of the flow field, which should provide a basis for estimating a convective heat losses, a parameter which influences their working characteristics. Heat losses are the result of the reflection on the glass, conductive losses at the collector's absorber plate, radiation of the absorber plate and convective losses on the glass. Wind velocity in the vicinity of the absorber plate depends on its position in the arrays of collectors. Results obtained in the numerical simulation of flow around collectors were used as boundary conditions in modeling of thermal-hydraulic processes inside the solar collector. A method for coupling thermal-hydraulic processes inside the collector with heat transfer from plate to tube bundle was developed, in order to find out the distribution of the temperature of the absorber plate and the efficiency of the flat plate collectors. Analyses of flow around arrays of collectors are preformed with RNG k - ε model. Three values for free-stream velocity were analysed, i.e. 1 m/s, 5 m/s and 10 m/s, as well as two values for the angle between the ground and the collector (20° and 40°. Heat transfer coefficient was determined from the theory of boundary layer. Heat transfer inside the plate cavity was analyzed assuming constant intensity of radiation.

  18. Up-date of traveling wave tube improvements

    Science.gov (United States)

    Buck, E.

    1978-01-01

    NASA research in the area of traveling wave tube technology is reviewed, with emphasis on the basic physics of guns and collectors and a computer model for the interaction between the electron beam and the RF circuit. The design of a multistage depressed collector, capable of multiplying tube efficiency by a factor of two or more, is presented; one such design has been adopted for commercial traveling wave tube production. A three-dimensional model of electron trajectories toward the collector also receives attention, as does the problem of RF circuit losses.

  19. LHCb Tag Collector

    CERN Document Server

    Fuente Fernàndez, P; Cousin, N

    2011-01-01

    The LHCb physics software consists of hundreds of packages, each of which is developed by one or more physicists. When the developers have some code changes that they would like released, they commit them to the version control system, and enter the revision number into a database. These changes have to be integrated into a new release of each of the physics analysis applications. Tests are then performed by a nightly build system, which rebuilds various configurations of the whole software stack and executes a suite of run-time functionality tests. A Tag Collector system has been developed using solid standard technologies to cover both the use cases of developers and integration managers. A simple Web interface, based on an AJAX-like technology, is available. Integration with software management and Nightly Build programs is possible via a Python API. Data are stored in a relational database with the help of an ORM (Object-Relational Mapping) library.

  20. Biobriefcase aerosol collector

    Science.gov (United States)

    Bell, Perry M [Tracy, CA; Christian, Allen T [Madison, WI; Bailey, Christopher G [Pleasanton, CA; Willis, Ladona [Manteca, CA; Masquelier, Donald A [Tracy, CA; Nasarabadi, Shanavaz L [Livermore, CA

    2009-09-22

    A system for sampling air and collecting particles entrained in the air that potentially include bioagents. The system comprises providing a receiving surface, directing a liquid to the receiving surface and producing a liquid surface. Collecting samples of the air and directing the samples of air so that the samples of air with particles entrained in the air impact the liquid surface. The particles potentially including bioagents become captured in the liquid. The air with particles entrained in the air impacts the liquid surface with sufficient velocity to entrain the particles into the liquid but cause minor turbulence. The liquid surface has a surface tension and the collector samples the air and directs the air to the liquid surface so that the air with particles entrained in the air impacts the liquid surface with sufficient velocity to entrain the particles into the liquid, but cause minor turbulence on the surface resulting in insignificant evaporation of the liquid.

  1. Selecting baghouse dust collectors

    Energy Technology Data Exchange (ETDEWEB)

    Moore, S.; Rubak, J.; Jolin, M. [Farr Co., El Segundo, CA (United States)]|[Farr Co., Laval, Quebec (Canada)

    1997-04-01

    A thorough analysis of the dust to be captured and determination of specific application requirements are necessary when designing a baghouse collection system. Independent consultants specializing in pollution control equipment and manufacturers with experience in several types of collectors are possible sources of assistance. These experts typically have testing facilities to analyze the dust characteristics. This final article of a two-part series on baghouse design and selection concentrates on application considerations created by the type of dust handled, selecting the best filtration media, selecting the best filtration media, and determining the air-to-cloth (A/C) ratio. The first article discussed bag sizing and cleaning methods and housing and hopper designs.

  2. Development of a Small Modular Parabolic trough Collector

    Energy Technology Data Exchange (ETDEWEB)

    Hoffschmidt, B.; Schwarzer, K.; Spate, F.; Kotter, J.; Ebert, M.; Sierck, O.

    2006-07-01

    A small parabolic trough collector is developed with the purpose to achieve a high efficiency at temperatures up to 300 degree Celsius. The collector has an aperture area of 1 m width and 2 m length. Therefore it can be used very easily for roof installations. Tests at the collector test stand of the Solar-Institut Juelich show good results up to 100 degree celsius. The power is about 1 kW. The collector's efficiency is above 50%. Stagnation experiments have shown temperatures around 590 degree celsius at a direct radiation of 730 W/square meters and 7 degree Celsius ambient temperature. The collector consists of a form giving rib construction of stainless steel covered with an aluminum reflector with a reflection coefficient of 95%. A standard vacuum tube (Sidney-principle) 200 cm long is used as absorber. Anti Reflex Glass with a solar transmission of more than 95% is used as cover. The tracking system is consisting of a stepper motor, transmission, sun sensor and electronic steering. (Author)

  3. Current collectors for improved safety

    Energy Technology Data Exchange (ETDEWEB)

    Abdelmalak, Michael Naguib; Allu, Srikanth; Dudney, Nancy J.; Li, Jianlin; Simunovic, Srdjan; Wang, Hsin

    2017-12-19

    A battery electrode assembly includes a current collector with conduction barrier regions having a conductive state in which electrical conductivity through the conduction barrier region is permitted, and a safety state in which electrical conductivity through the conduction barrier regions is reduced. The conduction barrier regions change from the conductive state to the safety state when the current collector receives a short-threatening event. An electrode material can be connected to the current collector. The conduction barrier regions can define electrical isolation subregions. A battery is also disclosed, and methods for making the electrode assembly, methods for making a battery, and methods for operating a battery.

  4. AEROSOL PARTICLE COLLECTOR DESIGN STUDY

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S; Richard Dimenna, R

    2007-09-27

    A computational evaluation of a particle collector design was performed to evaluate the behavior of aerosol particles in a fast flowing gas stream. The objective of the work was to improve the collection efficiency of the device while maintaining a minimum specified air throughput, nominal collector size, and minimal power requirements. The impact of a range of parameters was considered subject to constraints on gas flow rate, overall collector dimensions, and power limitations. Potential improvements were identified, some of which have already been implemented. Other more complex changes were identified and are described here for further consideration. In addition, fruitful areas for further study are proposed.

  5. Tsunami evacuation buildings and evacuation planning in Banda Aceh, Indonesia.

    Science.gov (United States)

    Yuzal, Hendri; Kim, Karl; Pant, Pradip; Yamashita, Eric

    Indonesia, a country of more than 17,000 islands, is exposed to many hazards. A magnitude 9.1 earthquake struck off the coast of Sumatra, Indonesia, on December 26, 2004. It triggered a series of tsunami waves that spread across the Indian Ocean causing damage in 11 countries. Banda Aceh, the capital city of Aceh Province, was among the most damaged. More than 31,000 people were killed. At the time, there were no early warning systems nor evacuation buildings that could provide safe refuge for residents. Since then, four tsunami evacuation buildings (TEBs) have been constructed in the Meuraxa subdistrict of Banda Aceh. Based on analysis of evacuation routes and travel times, the capacity of existing TEBs is examined. Existing TEBs would not be able to shelter all of the at-risk population. In this study, additional buildings and locations for TEBs are proposed and residents are assigned to the closest TEBs. While TEBs may be part of a larger system of tsunami mitigation efforts, other strategies and approaches need to be considered. In addition to TEBs, robust detection, warning and alert systems, land use planning, training, exercises, and other preparedness strategies are essential to tsunami risk reduction.

  6. A comparison between the solar energy collection by fix and tracking collectors

    Energy Technology Data Exchange (ETDEWEB)

    Garrison, John D [San Diego State University, San Diego (United States)

    2000-07-01

    A realistic mathematical simulation of solar thermal energy collection for an air flat plate collector, six designs of fixed evacuated collectors and two designs of tracking evacuated collectors at port Hardy, British Columbia and Edmonton, Alberta, in Canada and Daggett, California in the United States has been calculated. Differences in solar energy collection by the different collector designs arise only from differences in collector geometry, since the same collector orientations, selective absorber and solar radiation data are used in the simulations for all collector designs. It is found that solar energy collection in Canada by an air flat plate collector is significantly lower than that of the fixed evacuated and the tracking evacuated collectors at the lowest operating temperatures. This occurs because of the high thermal losses for the air flat plate collector, and the low solar insolation and low winter ambient temperatures in Canada. Highly concentrating tracking collectors which collect no diffuse radiation do not collect as much solar energy at lower temperatures as all of the fixed evacuated collectors at Port Hardy in Canada where there are a limited number of clear days. The fixed, vacuum tubular (dewar type) collector collects the most solar energy at low temperatures. At higher temperatures it collects the least amount of energy of all of the evacuated collectors. This is because of its low concentration and thus larger radiation losses. The vacuum vertical fin and higher concentration shaped glass evacuated collectors at high temperatures. Solar energy collection at Daggett is much higher than that at the two Canadian stations because of the high solar insolation and moderate to warm ambient temperatures. By rotating of the more highly concentrating CPC evacuated collectors about their axes placed parallel to the polar axis so as to track the sun, significantly higher energy collection is obtained, particularly for sites with higher annual

  7. Craft-Joule Project: Stagnation proof transparently insulated flat plate solar collector (static)

    Energy Technology Data Exchange (ETDEWEB)

    Oliva, A; Cadafalch, J; Perez-Segarra, C.D. [Universitat Politecnica de Catalunya, Barcelona (Spain)] (and others)

    2000-07-01

    The STATIC (STAgnation proof Transparently Insulated flat plate Solar Collector) project is a Craft-Joule Project within the framework of the Non Nuclear Energy Programme Joule III coordinated by the Centre Technologic de Transferencia de Calor (CTTC). The core group of SMEs involved in the project has its main economical activity in the field of solar thermal systems at low temperature level (domestic hot water, solar heating, etc.). Beyond this, a large application potential exists for solar heating at medium temperature level (from 80 to 160 Celsius degrees) : industrial process heat, solar cooling and air conditioning, solar drying , distillation and desalination. Three of the four SME proposers are located in Southern Europe and in the Caribean, where a continuos increase of the demand for air conditioning and cooling has been demonstrated in the last years. The recent development of flat plate solar collectors with honeycomb-type transparent insulation cover has shown that this type of collectors can become a low cost alternative to evacuated tube and high concentrating CPC collectors in the medium temperature range from 80 to 160 Celsius degrees. With the expected reduction of collector cost, that forms 30%-50% of total system cost, a decisive break-through of solar thermal systems using heat in the medium temperature range can be achieved. The feasibility and good performance of these solar collectors has been proved in several prototypes. Nevertheless, up to now no commercial products are available. In order to reach this, the following developments of new concepts are necessary and are being carried out within this project: solution of the problem of overheating: development of collector versions for different working temperatures: optimization of the design with the support of high level numerical simulation. Several prototypes of the new solar collectors are being tested. System tests will also be carried or for two test arrays of optimized collector

  8. Accelerated Testing of Solar Collector Durability

    DEFF Research Database (Denmark)

    Svendsen, Sv Aa Højgaard

    1996-01-01

    A climatic simulator has been build to test the reliability and durability of solar collectors. In the climatic simulator the collector is expåosed to extreme climatic conditions and temperature variations in an accelerated way and during this process the function of the collector is tested...... and the microclimate in the collector box is measured....

  9. Design features of vortex dust collectors

    Directory of Open Access Journals (Sweden)

    Puring Svetlana

    2017-01-01

    Full Text Available This article states that during the construction of industrial buildings it is necessary to provide engineering communications (including systems of supply and exhaust ventilation which ensure uninterrupted production, its technological and environmental safety. It is necessary to use cleaning devices to remove pollutants from ventilation emissions in local exhaust systems. As for devices for removing highly disperse non-sticky dust, it is possible to offer vortex dust collectors, the efficiency of which depends on the design and operating mode. A method is proposed to increase the efficiency of a vortex dust collector, to improve the quality of the purified air, and to reduce energy consumption during air purification by installing watering nozzles in primary and secondary air pipes made in the form of a Venturi tube. In consequence of multidirectional movement of dust particles and sprayed water, active coagulation of dust particles takes place, as a result of which the separation increases. Apart from that, watering dusty air flows leads to the formation of a liquid film on the inner surface of the separation chamber, which prevents dust particles from rebounding off the separation chamber and facilitates their capture and flushing into the collecting hopper

  10. Pedestrian and Evacuation Dynamics 2005

    CERN Document Server

    Gattermann, Peter; Knoflacher, Hermann; Schreckenberg, Michael

    2007-01-01

    Due to an increasing number of reported catastrophes all over the world, the safety especially of pedestrians today, is a dramatically growing field of interest, both for practitioners as well as scientists from various disciplines. The questions arising mainly address the dynamics of evacuating people and possible optimisations of the process by changing the architecture and /or the procedure. This concerns not only the case of ships, stadiums or buildings, all with restricted geometries, but also the evacuation of complete geographical regions due to natural disasters. Furthermore, also ‘simple’ crowd motion in ‘relaxed’ situations poses new questions with respect to higher comfort and efficiency since the number of involved persons at large events is as high as never before. In addition, as a new research topic in this field, collective animal behaviour is attracting increasing attention. All this was in the scope of the conference held in Vienna, September 28–30, 2005, the third one in a series ...

  11. Performance Evaluation of a Nanofluid-Based Direct Absorption Solar Collector with Parabolic Trough Concentrator.

    Science.gov (United States)

    Xu, Guoying; Chen, Wei; Deng, Shiming; Zhang, Xiaosong; Zhao, Sainan

    2015-12-04

    Application of solar collectors for hot water supply, space heating, and cooling plays a significant role in reducing building energy consumption. For conventional solar collectors, solar radiation is absorbed by spectral selective coating on the collectors' tube/plate wall. The poor durability of the coating can lead to an increased manufacturing cost and unreliability for a solar collector operated at a higher temperature. Therefore, a novel nanofluid-based direct absorption solar collector (NDASC) employing uncoated collector tubes has been proposed, and its operating characteristics for medium-temperature solar collection were theoretically and experimentally studied in this paper. CuO/oil nanofluid was prepared and used as working fluid of the NDASC. The heat-transfer mechanism of the NDASC with parabolic trough concentrator was theoretically evaluated and compared with a conventional indirect absorption solar collector (IASC). The theoretical analysis results suggested that the fluid's temperature distribution in the NDASC was much more uniform than that in the IASC, and an enhanced collection efficiency could be achieved for the NDASC operated within a preferred working temperature range. To demonstrate the feasibility of the proposed NDASC, experimental performances of an NDASC and an IASC with the same parabolic trough concentrator were furthermore evaluated and comparatively discussed.

  12. Solar collector manufacturing activity, 1992

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-09

    This report presents data provided by US-based manufacturers and importers of solar collectors. Summary data on solar thermal collector shipments are presented for the years 1974 through 1992. Summary data on photovoltaic cell and module shipments are presented for the years 1982 through 1992. Detailed information for solar thermal collectors and photovoltaic cells and modules are presented for 1992. Appendix A describes the survey methodology. Appendix B contains the 1992 survey forms and instructions. Appendices C and D list the companies that responded to the 1992 surveys and granted permission for their names and addresses to appear in the report. Appendix E provides selected tables from this report with data shown in the International System of Units (SI) metric units. Appendix F provides an estimate of installed capacity and energy production from solar collectors for 1992.

  13. Solar collector with altitude tracking

    Science.gov (United States)

    Barak, Amitzur Z.

    1977-01-01

    A device is provided for turning a solar collector about an east-west horizontal axis so that the collector is tilted toward the sun as the EWV altitude of the sun varies each day. It includes one or more heat responsive elements and a shading means aligned so that within a range of EWV altitudes of the sun during daylight hours the shading means shades the element or elements while during the rest of the daylight hours the elements or elements are heated by the sun to assume heated, stable states. Mechanical linkage between the collector and the element is responsive to the states of the element or elements to tilt the collector in accordance with variations in the EWV altitude of the sun.

  14. Modelling of Microclimate in collectors

    DEFF Research Database (Denmark)

    Holck, Ole

    1996-01-01

    Abstract It is important to avoid condensation in solar collectors, most of all because wetness of the absorber can damage the selective surface and cause corrosion on the absorber plate. During night time the cover of collectors will cool below ambient temperature due to thermal radiation...... to the cold sky. In climates where the air during night time becomes saturated with humidity (the relative humidity is 100%), condensation will form on the outside and inside of the collector glazing. If too much condensation takes place on the inside of the glazing, it will start to fall off...... on to the absorber surface. It is important to characterize microclimatic conditions in the collector, and at the Department of Buildings and Energy work is carried out with the improvement of a computer model. As a tool the computer model will be useful in developing guidelines to achieve the most favourable...

  15. Standard Practice for Exposure of Cover Materials for Solar Collectors to Natural Weathering Under Conditions Simulating Operational Mode

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This practice provides a procedure for the exposure of cover materials for flat-plate solar collectors to the natural weather environment at temperatures that are elevated to approximate operating conditions. 1.2 This practice is suitable for exposure of both glass and plastic solar collector cover materials. Provisions are made for exposure of single and double cover assemblies to accommodate the need for exposure of both inner and outer solar collector cover materials. 1.3 This practice does not apply to cover materials for evacuated collectors or photovoltaics. 1.4 The values stated in SI units are to be regarded as the standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Evacuation exercise at the Kindergarten

    CERN Multimedia

    2001-01-01

    Every year fire evacuation exercises are organized through out CERN and our facility's Kindergarten is no exception. Just a few weeks ago, a fire simulation was carried out in the Kindergarten kitchen facility using synthetic smoke. The purpose of the exercise was to teach staff to react in a disciplined and professional manner when in the presence of danger. The simulation is always carried out at a random time so as to ensure that people in the area under the test are not aware of the exercise. For the Kindergarten the exercise was held early in the school year so as to train those who are new to the establishment. The evacuation was a complete success and all went as it was supposed to. When the children and teachers smelt smoke they followed the prescribed evacuation routes and left the building immediately. Once outside the situation was revealed as an exercise and everyone went back to business as usual, everyone that is, except the fire brigade and fire inspector.  The fire brigade checked t...

  17. Elastocapillary mist collector

    Science.gov (United States)

    Duprat, Camille; Labbé, Romain; Rewakowicz, Ana

    2015-11-01

    Fibrous media are commonly used to collect droplets from an aerosol. In particular, woven textiles are used to harvest fresh water from fog, and coalescing filters made of non-woven entangled fibers are used to extract oil drops from gas streams. We propose a novel mist collector made of a forest of vertical flexible threads. As the droplets accumulate on the fibers, capillary bridges are formed, leading to the collapse of adjacent fibers thus forming liquid columns. This improve the liquid collection by preventing clogging, enabling high capture and precluding re-entrainment of drops in the gas stream due to the immediate coalescence of incoming droplets, and promoting fast drainage. We find that the collection flow rate is constant and can be adjusted by varying the fibers arrangement and flexibility. We show that there is an optimal situation for which this collection rate, i.e. the global efficiency, is maximal due to an elastocapillary coupling that we further characterize with a model experiment. Specifically, we study the drainage between two flexible fibers. Depending on the geometry and the fiber deformations, several flow regimes are observed. We characterize these regimes, and discuss the consequences on the drainage velocity, and thus the collection efficiency.

  18. ADVANCED HYBRID PARTICULATE COLLECTOR

    Energy Technology Data Exchange (ETDEWEB)

    Stanley J. Miller; Grant L. Schelkoph; Grant E. Dunham

    2000-12-01

    A new concept in particulate control, called an advanced hybrid particulate collector (AHPC), is being developed under funding from the US Department of Energy. The AHPC combines the best features of electrostatic precipitators (ESPs) and baghouses in an entirely novel manner. The AHPC concept combines fabric filtration and electrostatic precipitation in the same housing, providing major synergism between the two methods, both in the particulate collection step and in transfer of dust to the hopper. The AHPC provides ultrahigh collection efficiency, overcoming the problem of excessive fine-particle emissions with conventional ESPs, and solves the problem of reentrainment and recollection of dust in conventional baghouses. Phase I of the development effort consisted of design, construction, and testing of a 5.7-m{sup 3}/min (200-acfm) working AHPC model. Results from both 8-hour parametric tests and 100-hour proof-of-concept tests with two different coals demonstrated excellent operability and greater than 99.99% fine-particle collection efficiency.

  19. SOLAR NANTENNA ELECTROMAGNETIC COLLECTORS

    Energy Technology Data Exchange (ETDEWEB)

    Steven D. Novack; Dale K. Kotter; Dennis Slafer; Patrick Pinhero

    2008-08-01

    This research explores a new efficient approach for producing electricity from the abundant energy of the sun. A nanoantenna electromagnetic collector (NEC) has been designed, prototyped, and tested. Proof of concept has been validated. The device targets mid-infrared wavelengths where conventional photovoltaic (PV) solar cells do not respond but is abundant in solar energy. The initial concept of designing NEC antennas was based on scaling of radio frequency antenna theory. This approach has proven unsuccessful by many due to not fully understanding and accounting for the optical behavior of materials in the THz region. Also until recent years the nanofabrication methods were not available to fabricate the optical antenna elements. We have addressed and overcome both technology barriers. Several factors were critical in successful implementation of NEC including: 1) frequency-dependent modeling of antenna elements, 2) selection of materials with proper THz properties and 3) novel manufacturing methods that enable economical large-scale manufacturing. The work represents an important step toward the ultimate realization of a low-cost device that will collect as well as convert this radiation into electricity, which will lead to a wide spectrum, high conversion efficiency, and low cost solution to complement conventional PVs.

  20. Manifold Insulation for Solar Collectors

    Science.gov (United States)

    1982-01-01

    Results of computer analysis of effects of various manifold insulation detailed in 23-page report show that if fluid is distributed to and gathered from array of solar collectors by external rather than internal manifold, effectiveness of manifold insulation has major influence on efficiency. Report describes required input data and presents equations that govern computer model. Provides graphs comparing collector efficiencies for representative manifold sizes and insulations.

  1. Solar radiation on a catenary collector

    Science.gov (United States)

    Crutchik, M.; Appelbaum, J.

    1992-01-01

    A tent-shaped structure with a flexible photovoltaic blanket acting as a catenary collector is presented. The shadow cast by one side of the collector produces a shadow on the other side of the collector. This self-shading effect is analyzed. The direct beam, the diffuse, and the albedo radiation on the collector are determined. An example is given for the insolation on the collector operating on Viking Lander 1 (VL1).

  2. Research on temperature control and influence of the vacuum tubes with inserted tubes solar heater

    Science.gov (United States)

    Xiao, L. X.; He, Y. T.; Hua, J. Q.

    2017-11-01

    A novel snake-shape vacuum tube with inserted tubes solar collector is designed in this paper, the heat transfer characteristics of the collector are analyzed according to its structural characteristics, and the influence of different working temperature on thermal characteristics of the collector is studied. The solar water heater prototype consisting of 14 vacuum tubes with inserted tubes is prepared, and the hot water storage control subsystem is designed by hysteresis comparison algorithm. The heat characteristic of the prototype was experimentally studied under hot water output temperature of 40-45°C, 50-55°C and 60-65°C. The daily thermal efficiency was 64%, 50% and 46%, respectively. The experimental results are basically consistent with the theoretical analysis.

  3. Incidence angle modifiers in cylindrical solar collector design. Final report, June 1996--May 1997

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, J.P.

    1997-05-01

    This thesis presents an analysis of the thermal performance of cylindrical solar collectors. A major contributor to performance is optics, the principle focus of this work. A tool used to compute the incidence angle modifiers (IAM`s) for cylindrical solar collectors is presented. The Monte Carlo Method is employed in a Fortran 90 computer code to compute the hemispheric IAM`s of cylindrical solar collectors. Using concentric cylinders, the tubes are modeled with and without back plane reflectors of varying size. The computed IAM`s are verified both analytically and experimentally. Outdoor experiments on an array of cylindrical tubes with various back planes and two different tube spacings are described. Agreement with TRNSYS runs in daily energy gain is excellent. Over the 38 data sets, taken on different days, a maximum error of 11.2% is observed, with an average error of 3%. Heat loss tests, used to calculate an overall heat loss coefficient for the collector, are also described. A parametric variation study is used to illustrate the effect of varying many of the collector parameters. This study provides insight into the significant design parameters for cylindrical solar collectors. This insight is used to analyze the effect of these design parameters on the annual energy delivered by the collector. In addition, a simple cost analysis illustrates the benefits of varying the design parameters. The use of this new program and a detailed Life Cycle Cost analysis are the tools needed for optimizing the design of a cylindrical solar collector. 27 figs., 9 tabs.

  4. Experimental investigation of a nanofluid absorber employed in a low-profile, concentrated solar thermal collector

    Science.gov (United States)

    Li, Qiyuan; Zheng, Cheng; Mesgari, Sara; Hewakuruppu, Yasitha L.; Hjerrild, Natasha; Crisostomo, Felipe; Morrison, Karl; Woffenden, Albert; Rosengarten, Gary; Scott, Jason A.; Taylor, Robert A.

    2015-12-01

    Recent studies [1-3] have demonstrated that nanotechnology, in the form of nanoparticles suspended in water and organic liquids, can be employed to enhance solar collection via direct volumetric absorbers. However, current nanofluid solar collector experimental studies are either relevant to low-temperature flat plate solar collectors (100 °C) indoor laboratory-scale concentrating solar collectors [1, 5]. Moreover, many of these studies involve in thermal properties of nanofluid (such as thermal conductivity) enhancement in solar collectors by using conventional selective coated steel/copper tube receivers [6], and no full-scale concentrating collector has been tested at outdoor condition by employing nanofluid absorber [2, 6]. Thus, there is a need of experimental researches to evaluate the exact performance of full-scale concentrating solar collector by employing nanofluids absorber at outdoor condition. As reported previously [7-9], a low profile (solar thermal concentrating collector was designed and analysed which can potentially supply thermal energy in the 100-250 °C range (an application currently met by gas and electricity). The present study focuses on the design and experimental investigation of a nanofluid absorber employed in this newly designed collector. The nanofluid absorber consists of glass tubes used to contain chemically functionalized multi-walled carbon nanotubes (MWCNTs) dispersed in DI water. MWCNTs (average diameter of 6-13 nm and average length of 2.5-20 μm) were functionalized by potassium persulfate as an oxidant. The nanofluids were prepared with a MCWNT concentration of 50 +/- 0.1 mg/L to form a balance between solar absorption depth and viscosity (e.g. pumping power). Moreover, experimentally comparison of the thermal efficiency between two receivers (a black chrome-coated copper tube versus a MWCNT nanofluid contained within a glass tubetube) is investigated. Thermal experimentation reveals that while the collector efficiency

  5. Standard Practice for Exposure of Solar Collector Cover Materials to Natural Weathering Under Conditions Simulating Stagnation Mode

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 This practice covers a procedure for the exposure of solar collector cover materials to the natural weather environment at elevated temperatures that approximate stagnation conditions in solar collectors having a combined back and edge loss coefficient of less than 1.5 W/(m2 · °C). 1.2 This practice is suitable for exposure of both glass and plastic solar collector cover materials. Provisions are made for exposure of single and double cover assemblies to accommodate the need for exposure of both inner and outer solar collector cover materials. 1.3 This practice does not apply to cover materials for evacuated collectors, photovoltaic cells, flat-plate collectors having a combined back and edge loss coefficient greater than 1.5 W/(m2 ·° C), or flat-plate collectors whose design incorporates means for limiting temperatures during stagnation. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard t...

  6. Experimental performance analysis for mini-parabolic solar reflecting collectors

    Energy Technology Data Exchange (ETDEWEB)

    Barakos, G.; Kaplanis, S.; Spyrogiannoulas, A. [Technological Educational Inst. of Patras, Patra (Greece)

    2007-07-01

    This paper presented a detailed analysis of the thermal behaviour of a mini-parabolic solar reflecting collector installed on the roof of a building. A data logging system was used to monitor fluid inlet and outlet temperatures in the absorber; total solar radiation incident on the aperture surface; ambient temperatures; and fluid flow measurements. The aim of the study was to increase the reliability of the collector, maximize output, and optimize the geometrical and physical characteristics of the collector's components. Experiments were conducted over a 4-day period in October and November 2006 at a location in Greece. Data obtained during the experiments showed that as the mass flow rate increased, the outlet and inlet temperatures decreased. The system's efficiency increased as the mass flow rate increased. Losses were decreased when temperatures in the tube absorber remained low. The results of several subsequent experiments confirmed that higher mass flow rates increase the efficiency of the collectors.15 refs., 10 figs.

  7. Cellular automaton model of crowd evacuation inspired by slime mould

    Science.gov (United States)

    Kalogeiton, V. S.; Papadopoulos, D. P.; Georgilas, I. P.; Sirakoulis, G. Ch.; Adamatzky, A. I.

    2015-04-01

    In all the living organisms, the self-preservation behaviour is almost universal. Even the most simple of living organisms, like slime mould, is typically under intense selective pressure to evolve a response to ensure their evolution and safety in the best possible way. On the other hand, evacuation of a place can be easily characterized as one of the most stressful situations for the individuals taking part on it. Taking inspiration from the slime mould behaviour, we are introducing a computational bio-inspired model crowd evacuation model. Cellular Automata (CA) were selected as a fully parallel advanced computation tool able to mimic the Physarum's behaviour. In particular, the proposed CA model takes into account while mimicking the Physarum foraging process, the food diffusion, the organism's growth, the creation of tubes for each organism, the selection of optimum tube for each human in correspondence to the crowd evacuation under study and finally, the movement of all humans at each time step towards near exit. To test the model's efficiency and robustness, several simulation scenarios were proposed both in virtual and real-life indoor environments (namely, the first floor of office building B of the Department of Electrical and Computer Engineering of Democritus University of Thrace). The proposed model is further evaluated in a purely quantitative way by comparing the simulation results with the corresponding ones from the bibliography taken by real data. The examined fundamental diagrams of velocity-density and flow-density are found in full agreement with many of the already published corresponding results proving the adequacy, the fitness and the resulting dynamics of the model. Finally, several real Physarum experiments were conducted in an archetype of the aforementioned real-life environment proving at last that the proposed model succeeded in reproducing sufficiently the Physarum's recorded behaviour derived from observation of the aforementioned

  8. Effect of Installation of Solar Collector on Performance of Balcony Split Type Solar Water Heaters

    Directory of Open Access Journals (Sweden)

    Xu Ji

    2015-01-01

    Full Text Available The influences of surface orientation and slope of solar collectors on solar radiation collection of balcony split type solar water heaters for six cities in China were analyzed by employing software TRNSYS. The surface azimuth had greater effect on solar radiation collection in high latitude regions. For deviation of the surface slope angle within ±20° around the optimized angle, the variation of the total annual collecting solar radiation was less than 5%. However, with deviation of 70° to 90°, the variation was up to 20%. The effects of water cycle mode, reverse slope placement of solar collector, and water tank installation height on system efficiency were experimentally studied. The thermal efficiencies of solar water heater with single row horizontal arrangement all-glass evacuated tubular collector were higher than those with vertical arrangement at the fixed surface slope angle of 90°. Compared with solar water heaters with flat-plate collector under natural circulation, the system thermal efficiency was raised up to 63% under forced circulation. For collector at reverse slope placement, the temperature-based water stratification in water tank deteriorated, and thus the thermal efficiency became low. For improving the system efficiency, an appropriate installation height of the water tank was suggested.

  9. Pedestrian Evacuation Analysis for Tsunami Hazards

    Science.gov (United States)

    Jones, J. M.; Ng, P.; Wood, N. J.

    2014-12-01

    Recent catastrophic tsunamis in the last decade, as well as the 50th anniversary of the 1964 Alaskan event, have heightened awareness of the threats these natural hazards present to large and increasing coastal populations. For communities located close to the earthquake epicenter that generated the tsunami, strong shaking may also cause significant infrastructure damage, impacting the road network and hampering evacuation. There may also be insufficient time between the earthquake and first wave arrival to rely on a coordinated evacuation, leaving at-risk populations to self-evacuate on foot and across the landscape. Emergency managers evaluating these coastal risks need tools to assess the evacuation potential of low-lying areas in order to discuss mitigation options, which may include vertical evacuation structures to provide local safe havens in vulnerable communities. The U.S. Geological Survey has developed the Pedestrian Evacuation Analyst software tool for use by researchers and emergency managers to assist in the assessment of a community's evacuation potential by modeling travel times across the landscape and producing both maps of travel times and charts of population counts with corresponding times. The tool uses an anisotropic (directionally dependent) least cost distance model to estimate evacuation potential and allows for the variation of travel speed to measure its effect on travel time. The effectiveness of vertical evacuation structures on evacuation time can also be evaluated and compared with metrics such as travel time maps showing each structure in place and graphs displaying the percentage change in population exposure for each structure against the baseline. Using the tool, travel time maps and at-risk population counts have been generated for some coastal communities of the U.S. Pacific Northwest and Alaska. The tool can also be used to provide valuable decision support for tsunami vertical evacuation siting.

  10. Geiger-Muller tubes

    Energy Technology Data Exchange (ETDEWEB)

    Gair, S.A.; Copleston, R.E.

    1991-01-16

    A Geiger-Muller tube designed for use in an environment (for example, mounted on a rock drill) where subjected to mechanical shock and vibration has a tensioned anode wire secured by welding to securement members between first and second mounts at opposite ends of the tube envelope. The wire tension is adjusted to a high value with a screwable-adjustment means which is locked eg. by a spot-weld or by a locking nut, in the adjusted position, so that the natural frequency of the vibration of the tensioned wire does not resonate with (and may be much higher than) the frequencies to which the tube is subjected in use. The wire frequency is typically in excess of 400Hz and even 500Hz. The adjustment means may be included in the mount via which the envelope is evacuated and back-filled with the ionizible gas, and a gas-tight seal can be provided around this part of the mount, for example by sealing off the gas pump tube. However the adjustment means may be designed into another part of the tube, for example using telescopic parts of the envelope whose sliding junction is made gas tight with a flexible seal. (author).

  11. Performance Evaluation of a Nanofluid-Based Direct Absorption Solar Collector with Parabolic Trough Concentrator

    Directory of Open Access Journals (Sweden)

    Guoying Xu

    2015-12-01

    Full Text Available Application of solar collectors for hot water supply, space heating, and cooling plays a significant role in reducing building energy consumption. For conventional solar collectors, solar radiation is absorbed by spectral selective coating on the collectors’ tube/plate wall. The poor durability of the coating can lead to an increased manufacturing cost and unreliability for a solar collector operated at a higher temperature. Therefore, a novel nanofluid-based direct absorption solar collector (NDASC employing uncoated collector tubes has been proposed, and its operating characteristics for medium-temperature solar collection were theoretically and experimentally studied in this paper. CuO/oil nanofluid was prepared and used as working fluid of the NDASC. The heat-transfer mechanism of the NDASC with parabolic trough concentrator was theoretically evaluated and compared with a conventional indirect absorption solar collector (IASC. The theoretical analysis results suggested that the fluid’s temperature distribution in the NDASC was much more uniform than that in the IASC, and an enhanced collection efficiency could be achieved for the NDASC operated within a preferred working temperature range. To demonstrate the feasibility of the proposed NDASC, experimental performances of an NDASC and an IASC with the same parabolic trough concentrator were furthermore evaluated and comparatively discussed.

  12. Thin film solar energy collector

    Science.gov (United States)

    Aykan, Kamran; Farrauto, Robert J.; Jefferson, Clinton F.; Lanam, Richard D.

    1983-11-22

    A multi-layer solar energy collector of improved stability comprising: (1) a substrate of quartz, silicate glass, stainless steel or aluminum-containing ferritic alloy; (2) a solar absorptive layer comprising silver, copper oxide, rhodium/rhodium oxide and 0-15% by weight of platinum; (3) an interlayer comprising silver or silver/platinum; and (4) an optional external anti-reflective coating, plus a method for preparing a thermally stable multi-layered solar collector, in which the absorptive layer is undercoated with a thin film of silver or silver/platinum to obtain an improved conductor-dielectric tandem.

  13. 14 CFR 29.803 - Emergency evacuation.

    Science.gov (United States)

    2010-01-01

    ... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... Emergency evacuation. (a) Each crew and passenger area must have means for rapid evacuation in a crash... folding seats. (e) A combination of analysis and tests may be used to show that the rotorcraft is capable...

  14. 14 CFR 25.803 - Emergency evacuation.

    Science.gov (United States)

    2010-01-01

    ... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... evacuation. (a) Each crew and passenger area must have emergency means to allow rapid evacuation in crash... must be shown by actual demonstration using the test criteria outlined in appendix J of this part...

  15. Modelling Traveller Behaviour under Emergency Evacuation Conditions

    NARCIS (Netherlands)

    Pel, A.J.; Bliemer, M.C.J.; Hoogendoorn, S.P.

    2011-01-01

    Dynamic traffic simulation models are frequently used to support decisions when planning an evacuation. This paper focuses on limitations in the modelling of travellers’ behaviour with respect to traffic information and compliance to evacuation instructions. More specifically, we propose a model

  16. Performance verification of an air solar collector

    Science.gov (United States)

    Miller, D. C.; Romaker, R. F.

    1979-01-01

    Procedures and results of battery of qualification tests performed by independent certification agency on commercial solar collector are presented in report. Reported results were used as basis in judging collector suitable for field installation in residential and commerical buildings.

  17. Pet Ownership and Evacuation Prior to Hurricane Irene

    OpenAIRE

    Hunt, Melissa G.; Bogue, Kelsey; Rohrbaugh, Nick

    2012-01-01

    Simple Summary Ninety pet owners and 27 non-pet owners who lived in mandatory evacuation zones during the 2011 Hurricane Irene were surveyed about whether or not they evacuated and about their experiences during the hurricane. Although pet-ownership was not statistically associated with evacuation failure, many pet owners who chose not to evacuate still claimed that they did not evacuate because of difficulties with evacuating their pet. These findings suggest that more work needs to be done ...

  18. Bilinear reduced order approximate model of parabolic distributed solar collectors

    KAUST Repository

    Elmetennani, Shahrazed

    2015-07-01

    This paper proposes a novel, low dimensional and accurate approximate model for the distributed parabolic solar collector, by means of a modified gaussian interpolation along the spatial domain. The proposed reduced model, taking the form of a low dimensional bilinear state representation, enables the reproduction of the heat transfer dynamics along the collector tube for system analysis. Moreover, presented as a reduced order bilinear state space model, the well established control theory for this class of systems can be applied. The approximation efficiency has been proven by several simulation tests, which have been performed considering parameters of the Acurex field with real external working conditions. Model accuracy has been evaluated by comparison to the analytical solution of the hyperbolic distributed model and its semi discretized approximation highlighting the benefits of using the proposed numerical scheme. Furthermore, model sensitivity to the different parameters of the gaussian interpolation has been studied.

  19. Application of Induction Heating for Brazing Parts of Solar Collectors

    Directory of Open Access Journals (Sweden)

    Kristína Demianová

    2012-01-01

    Full Text Available This paper reports on the application of induction heating for brazing parts of solar collectors made of Al alloys. The tube-flange joint is a part of the collecting pipe of a solar collector. The main task was to design an induction coil for this type of joint, and to select the optimum brazing parameters. Brazing was performed with AlSi12 brazing alloy, and corrosive and non-corrosive flux types were also applied. The optimum brazing parameters were determined on the basis of testing the fabricated brazed joints by visual inspection, by leakage tests, and by macro- and micro-analysis of the joint boundary. The following conditions can be considered to be the best for brazing Al materials: power 2.69 kW,brazing time 24 s, flux BrazeTec F32/80.

  20. Buoyancy effects on thermal behavior of a flat-plate solar collector

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon

    2008-01-01

    Theoretical and experimental investigations of the flow and temperature distribution in a 12.53 m(2) solar collector panel with an absorber consisting of two vertical manifolds interconnected by 16 parallel horizontal fins have been carried out. The investigations are focused on overheating...... and the influence of the buoyancy effects are considered in the investigations. Further experimental investigations of the solar collector panel are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the back of the absorber tubes. The measured temperatures....... The CFD calculations elucidate the flow and temperature distribution in the collector panels of different designs. Based on the investigations, recommendations are given in order to avoid overheating or boiling problems in the solar collector panel....

  1. Thermal performance evaluation of the Suncatcher SH-11 (liquid) solar collector

    Science.gov (United States)

    1980-01-01

    The procedures used and the results obtained during the evaluation test program on the Solar Unlimited, Inc., Suncatcher SH-11 (liquid) solar collector are presented. The flat-plate collector case assembly is made of .08 inch aluminum 3003 H14 riveted with fiberglass board insulation. The absorber consists of collared aluminum fins mechanically bonded to 3/8 inch copper tubing and coated with 3M Nextel black. Water is used as the working fluid. The glazing is made of a single glass, 1/8 inch water white, tempered and antireflective. The collector weight is 85 pounds with overall external dimensions of about 35.4 in x 82.0 in x 4.0 in. Thermal performance data on the Solar Unlimited Suncatcher SH-11 solar collector under simulated conditions were conducted using the MSFC Solar Simulator.

  2. Investigations on efficiencies of HT solar collectors for different flow rates and collector tilts

    DEFF Research Database (Denmark)

    Chen, Ziqian; Perers, Bengt; Furbo, Simon

    2013-01-01

    Two HT solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one solar collector is equipped with an ETFE foil between the abso......Two HT solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one solar collector is equipped with an ETFE foil between...... the absorber and the cover glass and the other is without ETFE foil. The efficiencies for the collectors are tested at different flow rates and tilt. On the basis of the measured efficiencies, the efficiencies for the collectors as functions of flow rates are obtained. The calculated efficiencies are in good...

  3. Decision Dynamics in Group Evacuation

    CERN Document Server

    Han, Fangqiu; Schlesinger, Kimberly J; Gür, Izzeddin; Carlson, Jean M

    2016-01-01

    Identifying factors that affect human decision making and quantifying their influence remain essential and challenging tasks for the design and implementation of social and technological communication systems. We report results of a behavioral experiment involving decision making in the face of an impending natural disaster. In a controlled laboratory setting, we characterize individual and group evacuation decision making influenced by several key factors, including the likelihood of the disaster, available shelter capacity, group size, and group decision protocol. Our results show that success in individual decision making is not a strong predictor of group performance. We use an artificial neural network trained on the collective behavior of subjects to predict individual and group outcomes. Overall model accuracy increases with the inclusion of a subject-specific performance parameter based on laboratory trials that captures individual differences. In parallel, we demonstrate that the social media activit...

  4. Pedestrian and Evacuation Dynamics 2012

    CERN Document Server

    Kirsch, Uwe; Schreckenberg, Michael

    2014-01-01

    The 6th International Conference on Pedestrian and Evacuation Dynamics conference (PED2012) showcased research on human locomotion. This book presents the proceedings of PED2012. Humans have walked for eons; our drive to settle the globe began with a walk out of Africa. However, much remains to discover. As the world moves toward sustainability while racing to assess and accommodate climate change, research must provide insight on the physical requirements of walking, the dynamics of pedestrians on the move and more. We must understand, predict and simulate pedestrian behaviour, to avoid dangerous situations, to plan for emergencies, and not least, to make walking more attractive and enjoyable. PED2012 offered 70 presentations and keynotes and 70 poster presentations covering new and improved mathematical models, describing new insights on pedestrian behaviour in normal and emergency cases and presenting research based on sensors and advanced observation methods. These papers offer a starting point for innova...

  5. Solar Air Collectors for Space Heating and Ventilation Applications—Performance and Case Studies under Romanian Climatic Conditions

    Directory of Open Access Journals (Sweden)

    Sanda Budea

    2014-06-01

    Full Text Available Solar air collectors have various applications: on the one hand, they can be used for air heating in cold seasons; on the other hand they can be used in summer to evacuate the warm and polluted air from residential, offices, industrial, and commercial buildings. The paper presents experimental results of a solar collector air, under the climatic conditions of the Southeastern Europe. The relationships between the direct solar irradiation, the resulting heat flow, the air velocity at the outlet, the air flow rate, the nominal regime of the collector and the efficiency of conversion of solar energy into thermal energy are all highlighted. Thus, it was shown that after a maximum 50 min, solar air collectors, with baffles and double air passage can reach over 50% efficiency for solar irradiation of 900–1000 W/m2. The article also presents a mathematical model and the results of a computational program that allows sizing solar collectors for the transfer of air, with the purpose of improving the natural ventilation of buildings. The article is completed with case studies, sizing the area to be covered with solar collectors, to ensure ventilation of a house with two floors or for an office building. In addition, the ACH (air change per hour coefficient was calculated and compared.

  6. Assessment of Energy, Environmental and Economic Performance of a Solar Desiccant Cooling System with Different Collector Types

    Directory of Open Access Journals (Sweden)

    Giovanni Angrisani

    2014-10-01

    Full Text Available Desiccant-based air handling units can achieve reductions in greenhouse gas emissions and energy savings with respect to conventional air conditioning systems. Benefits are maximized when they interact with renewable energy technologies, such as solar collectors. In this work, experimental tests and data derived from scientific and technical literature are used to implement a model of a solar desiccant cooling system, considering three different collector technologies (air, flat-plate and evacuated collectors. Simulations were then performed to compare the energy, environmental and economic performance of the system with those of a desiccant-based unit where regeneration thermal energy is supplied by a natural gas boiler, and with those of a conventional air-handling unit. The only solution that allows achieving the economic feasibility of the solar desiccant cooling unit consists of 16 m2 of evacuated solar collectors. This is able to obtain, with respect to the reference system, a reduction of primary energy consumption and of the equivalent CO2 emissions of 50.2% and 49.8%, respectively, but with a payback time of 20 years.

  7. TUBE TESTER

    Science.gov (United States)

    Gittings, H.T. Jr.; Kalbach, J.F.

    1958-01-14

    This patent relates to tube testing, and in particular describes a tube tester for automatic testing of a number of vacuum tubes while in service and as frequently as may be desired. In it broadest aspects the tube tester compares a particular tube with a standard tube tarough a difference amplifier. An unbalanced condition in the circuit of the latter produced by excessive deviation of the tube in its characteristics from standard actuates a switch mechanism stopping the testing cycle and indicating the defective tube.

  8. A Case of Re-Expansion Pulmonary Edema after Rapid Pleural Evacuation

    Directory of Open Access Journals (Sweden)

    SH Shahbazi

    2007-07-01

    Full Text Available Introduction & Objective: Pulmonary edema after chest tube insertion is a rare complication and is associated with high mortality. The cause of this phenomenon is not clear, although causes such as decrease in surfactant and inflammatory process have been defined. Early diagnosis and treatment decrease the mortality. This study introduces a case of re-expansion pulmonary edema after rapid pleural evacuation. Case: The case is a 4.5 y/o boy, a case of Tetralogy of Fallot, who developed respiratory distress after surgery (Total Correction in ICU of Namazi Hospital in 1385. Chest X ray showed pneumothorax of left lung. For the patient, chest tube was inserted and the symptoms improved. After few hours the patient developed tachypnea, tachycardia, and CXR showed pulmonary edema of left lung. Appropriate treatment was done for the patient and his condition improved. Conclusion: Pulmonary edema after sudden evacuation of pleura is a rare phenomenon and early diagnosis decreases the mortality.

  9. Tsunami evacuation simulation considering differences in evacuation means depending on the household attribute

    Science.gov (United States)

    Sugiki, Nao; Hirata, Yoshiki; Matsuo, Kojiro

    2017-10-01

    Large scale earthquakes occur frequently in Japan in recent years. In the Great East Japan Earthquake that occurred in 2011 and caused major damage, more than 90% of the dead were due to the tsunami. The speed of evacuation is important in considering evacuation at the time of the attack of the tsunami, especially the elderly evacuation speed is assumed to be slower than non-elderly people. Elderly people may have different means of evacuation and speed depending on the composition of the households to which they belong because of the different possibilities of riding in families' driven cars. However, a simulation taking such a difference of evacuation into consideration has not been conducted. The purpose of this study is to conduct a tsunami evacuation simulation in consideration of evacuation measures and speed depending on the type of households belonging to in the tsunami inundation area of Toyohashi city, Japan. In order to conduct the tsunami evacuation simulation considering the household type, detailed data on individual households is necessary. However, it is difficult to obtain from aggregated data such as National Census. Therefore, detailed data on individual households is created by using the household micro data estimation system developed by Sugiki et al. [1]. Evacuation simulation is performed by shortest path search using Esri's ArcGIS Network Analyst's OD cost matrix analysis. The elderly people who cannot complete evacuation by the time of the arrival of the tsunami were found from evacuation simulation results assuming evacuation measures available for each household attribute to which the evacuees belong.

  10. Engineering of solar photocatalytic collectors

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, S.M.; Galvez, J.B.; Rubio, M.I.M.; Ibanez, P.F.; Padilla, D.A. [Plataforma Solar de Almeria (CIEMAT) (Spain); Pereira, M.C.; Mendes, J.F. [Instituto Nacional de Engenharia e Tecnologica Industrial, Lisbon (Portugal); Correia de Oliveira, J. [Aosol Energias Renovaveis Lda, Porto Alto (Portugal)

    2004-11-01

    This paper briefly describes the different collectors used in solar photocatalysis for wastewater treatment and, based on prior experience, the main advantages and disadvantages of each. As the tubular-shape reactor configuration is the most appropriate for handling and pumping water, the compound parabolic collector (CPC) is proposed as an interesting combination of parabolic concentrators and flat static systems and constitutes a good option for solar photochemical applications. The design of compound parabolic concentrators for solar photocatalytic applications is described in detail and 25-50 mm is proposed as the optimum photoreactor diameter, based on the optical characteristics and optimum concentration of the two photocatalytic systems (TiO{sub 2} and photo-Fenton) that can be used with sunlight for wastewater treatment. It has been demonstrated that since aluminium is the only metal that is highly reflective in the ultraviolet spectrum of solar radiation, aluminium-based mirrors are the best option. But, especially when exposed to outdoor conditions, aluminium must be protected and, therefore, at the present time, anodised and electropolished aluminium surfaces are considered the most suitable solutions. As the photochemical reactor contain the working fluid, including the catalyst, it must transmit UV sunlight efficiently and be able to work under enough pressure to handle the high volumes resulting from the large number of collectors in an industrial treatment plant, only low-iron glass is proposed as feasible for constructing the photoreactor (collector absorbers). Finally, ray-tracing algorithm simulations are presented as a design tool for the optical configuration of a particular reactor, drawing conclusions for its improvement and assisting in final engineering decision-making. (Author)

  11. Testing of PCM Heat Storage Modules with Solar Collectors as Heat Source

    DEFF Research Database (Denmark)

    Englmair, Gerald; Dannemand, Mark; Johansen, Jakob Berg

    2016-01-01

    was to actively utilize the ability of the material to supercool to obtain long storage periods. The modules were charged with solar heat supplied by 22.4 m2 evacuated tubular collectors. The investigation showed that it was possible to fully charge one module within a period of 270 minutes with clear skies......A latent heat storage based on the phase change material Sodium Acetate Trihydrate (SAT) has been tested as part of a demonstration system. The full heat storage consisted of 4 individual modules each containing about 200 kg of sodium acetate trihydrate with different additives. The aim...

  12. Dual axis solar collector assembly

    Energy Technology Data Exchange (ETDEWEB)

    Eiden, G.E.

    1991-02-19

    This patent describes a solar collector. It comprises: an elongate main boom having a longitudinal axis; a solar collector frame first mounting means for pivotally mounting the solar collector frame to the main boom for pivotal motion about first pivotal axis substantially parallel to the longitudinal axis of the main boom; and first motor means, separate from the first mounting means a generally horizontal countertop mounted on the frame means adapted for a placement and retention of an ostomy bag thereon during cleaning of the ostomy bag. The countertop having a sink formed therein for draining liquid and waste materials from the ostomy bag and from the countertop; a mirror mounted upright on the frame means; a light source mounted to the frame means for illuminating the countertop, a user and the mirror; and a drainage conduit, having a first end connected to the sink, the drainage conduit being adapted for carrying the waste materials and the liquid from the sink to the disposal location.

  13. The Bali bombing: civilian aeromedical evacuation.

    Science.gov (United States)

    Tran, Minh D; Garner, Alan A; Morrison, Ion; Sharley, Peter H; Griggs, William M; Xavier, Colin

    2003-10-06

    After the Bali bombing on 12 October 2002, many injured Australians required evacuation to Darwin, and then to burns units around Australia. Many patients were evacuated from Denpasar by Qantas, with assistance from staff of civilian medical retrieval services. The transport of patients from Darwin to specialist burns units involved a coordinated response of civilian and military services. Some issues in responding to such disasters were identified, and a national coordinating network could improve future responses.

  14. Proceedings of Pedestrian and Evacuation Dynamics 2016

    OpenAIRE

    Song, Weiguo; Ma, Jian; Fu, Libi

    2017-01-01

    The 8th International Conference on Pedestrian and Evacuation Dynamics (PED 2016) has been held on October 17–21, 2016 in Hefei, China. PED 2016 Conference offered an opportunity for professionals and scientists with different backgrounds to present and discuss new findings and applications in the field of pedestrian and evacuation dynamics and associated human behavior. The conference aims to provide suggestions for policy makers, planners, designers and emergency management to solve real wo...

  15. Fog collectors and collection techniques

    Science.gov (United States)

    Höhler, I.; Suau, C.

    2010-07-01

    The earth sciences taught that due to the occurrence of water in three phases: gas, liquid and solid, solar energy keeps the hydrological cycle going, shaping the earth surface while regulating the climate and thus allowing smart technologies to interfere in the natural process by rerouting water and employing its yield for natural and human environments’ subsistence. This is the case of traditional fog collectors implemented by several researchers along the Atacama Desert since late ’50s such as vertical tensile mesh or macro-diamonds structures. Nevertheless, these basic prototypes require to be upgraded, mainly through new shapes, fabrics and frameworks’ types by following the principles of lightness, transformability, portability and polyvalence. The vertical canvas of conventional fog collectors contain too much stressed at each joints and as result it became vulnerable. Our study constitutes a research by design of two fog-trap devices along the Atacama Desert. Different climatic factors influence the efficiency of fog harvesting. In order to increase yield of collected fog water, we need to establish suitable placements that contain high rates of fog’s accumulation. As important as the location is also the building reliability of these collectors that will be installed. Their frames and skins have to be adjustable to the wind direction and resistant against strong winds and rust. Its fabric need to be more hydrophobic, elastic and with light colours to ease dripping/drainage and avoid ultra-violet deterioration. In addition, meshes should be well-tensed and frames well-embraced too. In doing so we have conceived two fog collectors: DropNet© (Höhler) and FogHive© (Suau). These designs explore climatic design parameters combined with the agile structural principles of Tensegrity and Geodesic widely developed by Bucky Fuller and Frei Otto. The research methods mainly consisted of literature review; fieldwork; comparative analysis of existing fog

  16. Thermal and optical efficiency investigation of a parabolic trough collector

    Directory of Open Access Journals (Sweden)

    C. Tzivanidis

    2015-09-01

    Full Text Available Solar energy utilization is a promising Renewable Energy source for covering a variety of energy needs of our society. This study presents the most well-known solar concentrating system, the parabolic trough collector, which is operating efficiently in high temperatures. The simulation tool of this analysis is the commercial software Solidworks which simulates complicated problems with an easy way using the finite elements method. A small parabolic trough collector model is designed and simulated for different operating conditions. The goal of this study is to predict the efficiency of this model and to analyze the heat transfer phenomena that take place. The efficiency curve is compared to a one dimensional numerical model in order to make a simple validation. Moreover, the temperature distribution in the absorber and inside the tube is presented while the heat flux distribution in the outer surface of the absorber is given. The heat convection coefficient inside the tube is calculated and compared with the theoretical one according to the literature. Also the angle efficiency modifier is calculated in order to predict the thermal and optical efficiency for different operating conditions. The final results show that the PTC model performs efficiently and all the calculations are validated.

  17. Evacuation proctography: a reappraisal of normal variability.

    Science.gov (United States)

    Palit, S; Bhan, C; Lunniss, P J; Boyle, D J; Gladman, M A; Knowles, C H; Scott, S M

    2014-07-01

    Interpretation of evacuation proctography (EP) images is reliant on robust normative data. Previous studies of EP in asymptomatic subjects have been methodologically limited. The aim of this study was to provide parameters of normality for both genders using EP. Evacuation proctography was prospectively performed on 46 healthy volunteers (28 women). Proctograms were independently analysed by two reviewers. All established and some new variables of defaecatory structure and function were assessed objectively: anorectal dimensions; anorectal angle changes; evacuation time; percentage contrast evacuated; and incidence of rectal wall morphological 'abnormalities'. Normal ranges were calculated for all main variables. Mean end-evacuation time was 88 s (95% CI: 63-113) in male subjects and 128 s (95% CI: 98-158) in female subjects; percentage contrast evacuated was 71% (95% CI: 63-80) in male subjects and 65% (95% CI: 58-72) in female subjects. Twenty-six (93%) of 28 female subjects had a rectocoele with a mean depth of 2.5 cm (upper limit = 3.9 cm). Recto-rectal intussusception was found in nine subjects (approximately 20% of both genders); however, recto-anal intussusception was not observed. Only rectal diameter differed significantly between genders. Qualitatively, three patterns of evacuation were present. This study defines normal ranges for anorectal dimensions and parameters of emptying, as well as the incidence and characteristics of rectal-wall 'abnormalities' observed or derived from EP. These ranges can be applied clinically for subsequent disease comparison. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  18. Automated solar collector installation design

    Science.gov (United States)

    Wayne, Gary; Frumkin, Alexander; Zaydman, Michael; Lehman, Scott; Brenner, Jules

    2014-08-26

    Embodiments may include systems and methods to create and edit a representation of a worksite, to create various data objects, to classify such objects as various types of pre-defined "features" with attendant properties and layout constraints. As part of or in addition to classification, an embodiment may include systems and methods to create, associate, and edit intrinsic and extrinsic properties to these objects. A design engine may apply of design rules to the features described above to generate one or more solar collectors installation design alternatives, including generation of on-screen and/or paper representations of the physical layout or arrangement of the one or more design alternatives.

  19. A method of emotion contagion for crowd evacuation

    Science.gov (United States)

    Cao, Mengxiao; Zhang, Guijuan; Wang, Mengsi; Lu, Dianjie; Liu, Hong

    2017-10-01

    The current evacuation model does not consider the impact of emotion and personality on crowd evacuation. Thus, there is large difference between evacuation results and the real-life behavior of the crowd. In order to generate more realistic crowd evacuation results, we present a method of emotion contagion for crowd evacuation. First, we combine OCEAN (Openness, Extroversion, Agreeableness, Neuroticism, Conscientiousness) model and SIS (Susceptible Infected Susceptible) model to construct the P-SIS (Personalized SIS) emotional contagion model. The P-SIS model shows the diversity of individuals in crowd effectively. Second, we couple the P-SIS model with the social force model to simulate emotional contagion on crowd evacuation. Finally, the photo-realistic rendering method is employed to obtain the animation of crowd evacuation. Experimental results show that our method can simulate crowd evacuation realistically and has guiding significance for crowd evacuation in the emergency circumstances.

  20. Optimization of dish solar collectors

    Science.gov (United States)

    Jaffe, L. D.

    1983-01-01

    Methods for optimizing parabolic dish solar collectors and the consequent effects of various optical, thermal, mechanical, and cost variables are examined. The most important performance optimization is adjusting the receiver aperture to maximize collector efficiency. Other parameters that can be adjusted to optimize efficiency include focal length, and, if a heat engine is used, the receiver temperature. The efficiency maxima associated with focal length and receiver temperature are relatively broad; it may, accordingly, be desirable to design somewhat away from the maxima. Performance optimization is sensitive to the slope and specularity errors of the concentrator. Other optical and thermal variables affecting optimization are the reflectance and blocking factor of the concentrator, the absorptance and losses of the receiver, and, if a heat engine is used, the shape of the engine efficiency versus temperature curve. Performance may sometimes be improved by use of an additional optical element (a secondary concentrator) or a receiver window if the errors of the primary concentrator are large or the receiver temperature is high. Previously announced in STAR as N83-19224

  1. Panic evacuation of single pedestrians and couples

    Science.gov (United States)

    Frank, G. A.; Dorso, C. O.

    2016-02-01

    Understanding the timing requirements for evacuation of people has focused primarily on independent pedestrians rather than pedestrians emotionally connected. However, the main statistical effects observed in crowds, the so-called “faster is slower”, “clever is not always better” and the “low visibility enhancement”, cannot explain the overall behavior of a crowd during an evacuation process when correlated pedestrians due to, for example feelings, are present. Our research addresses this issue and examines the statistical behavior of a mixture of individuals and couples during a (panic) escaping process. We found that the attractive feeling among couples plays an important role in the time delays during the evacuation of a single exit room.

  2. Evacuation and assembly of aerogel glazings

    DEFF Research Database (Denmark)

    Jensen, Karsten Ingerslev

    1999-01-01

    EU project a promising method was proposed, so the time for evacuation could be reduced from several hours to a few minutes.The aim of this project was to design and build an apparatus for evacuation and assembly of aerogel glazings up to 60 cm x 60 cm based on the proposed method.The key element...... of the method is the vacuum chamber in which the aerogel glazing is prior to mounting of the last glass pane. This glass pane is kept above the rest of the glazing while the chamber is evacuated. When the desired gas pressure is reached the glazing is assembled and the chamber is ventilated. Due to the fast...

  3. PERFORMANCE CHARACTERISTICS OF PARABOLIC SOLAR COLLECTOR WATER HEATER SYSTEM FITTED WITH NAIL TWISTED TAPES ABSORBER

    Directory of Open Access Journals (Sweden)

    K. SYED JAFAR

    2017-03-01

    Full Text Available In this paper, the experimental heat transfer, friction loss and thermal performance data for water flowing through the absorber tube fitted with two different twisted tape configurations in parabolic trough collector (PTC are presented. In the present work, a relative experimental study is carried out to investigate the performance of a PTC influenced by heat transfer through fluidabsorber wall mixing mechanism. The major findings of this experiment show that heat transport enhancement in the nail twisted tape collector perform significantly better than plain twisted tapes and also show that the smallest twisted tape ratio enhances the system performance remarkably maximizing the collector efficiency. The results suggest that the twisted tape and nail twisted tape would be a better option for high thermal energy collection in laminar region of the PTC system.

  4. Foldable Frame Supporting Electromagnetic Radiation Collectors

    DEFF Research Database (Denmark)

    2011-01-01

    The present invention relates to flexible frames supporting electromagnetic radiation collectors, such as antennas, antenna reflectors, deflectors or solar collectors, for celestial or terrestrial applications, which can be folded to be stored and/or transported. The method for stowing deforms...

  5. Cleaner for Solar-Collector Covers

    Science.gov (United States)

    Frickland, P. O.; Cleland, E. L.

    1983-01-01

    Simple self-contained cleaning system proposed for solar collectors or solar-collector protective domes. Perforated transparent plastic cap attached to top of protective dome in heliostat solar-energy collection system distributes cleaning fluid over surface of dome without blocking significant fraction of solar radiation.

  6. Combined solar collector and energy storage system

    Science.gov (United States)

    Jensen, R. N. (Inventor)

    1980-01-01

    A combined solar energy collector, fluid chiller and energy storage system is disclosed. A movable interior insulated panel in a storage tank is positionable flush against the storage tank wall to insulate the tank for energy storage. The movable interior insulated panel is alternately positionable to form a solar collector or fluid chiller through which the fluid flows by natural circulation.

  7. Weathering of a liquid solar collector

    Science.gov (United States)

    1980-01-01

    Commercially available flate plate hot water solar collector is characterized in report that presents 10 month weathering study of system. Collector efficiency was calculated and plotted from measurements of fluid temperature and flow rate, ambient temperature and solar flux. Windspeed and wind direction were also measured during tests.

  8. [Results of the study of motor and evacuation function of the stomach after gastroplasty].

    Science.gov (United States)

    Serikova, S N; Korochanskaia, N V; Durleshter, V M

    2013-01-01

    Investigation of motor and evacuated functions of upper parts of digestive tract in patients with hard scarring gastric ulcers (HSGU) after organ-preserving surgery by gastroplasty method. Motor and evacuated functions of the operated stomach were studied in 74 patients after gastroplasty (GP) with invaginated corporo-antral anastomosis (CAA) and 30 patients after GP with corporo-antral sphincter (KAS) formation from the ileal loop in different post-operated periods. The roentgenologic barium passage trough the upper parts of digestive tract and inter-digestive motor activity were assessed. The recovery of functional condition of the operated stomach after GP occurred during a year. It stipulated by adequate motor and evacuated functions of anastomosis performed. The GP technique with KAS formation from the ileal loop has number of advantages before its analogue GP with invaginated KAA: the muscular cuff from the ileal loop obstacles the dilatation of gastric tube; recovers the reservoir function of the fundal gastric part; provides the bolus portioned delivery to antral gastric portion to prevent its overload. The results of the study of motor and evacuated functions of operated stomach have proved that GP with KAS formation from the ileal loop was the optimal method of HSGU surgical treatment.

  9. Electrostatic particle collector with improved features for installing and/or removing its collector plates

    Energy Technology Data Exchange (ETDEWEB)

    Siegfried, Matthew J.; Radford, Daniel R.; Huffman, Russell K.

    2017-04-04

    An electrostatic particle collector may generally include a housing having sidewalls extending lengthwise between a first end and a second end. The housing may define a plate slot that extends heightwise within the housing between a top end and a bottom end. The housing may further include a plate access window that provides access to the bottom end of the plate slot. The collector may also include a collector plate configured to be installed within the plate slot that extends heightwise between a top edge and a bottom edge. Additionally, when the collector plate is installed within the plate slot, the bottom edge of the collector plate may be accessible from an exterior of the housing via the plate access window so as to allow the bottom edge of the collector plate to be moved relative to the housing to facilitate removal of the collector plate from the housing.

  10. Nocturnal radiation from a solar collector

    Science.gov (United States)

    Wang, H. F.; Chiang, C. W.

    1980-11-01

    As the sky temperature during the night is relatively low compared to the ambient temperature, the temperature of the absorber plate in a solar collector can be lower than the ambient temperature due to nocturnal radiation. Measurements have been made for Lennox Solar Collectors installed in a solar heating and cooling project, a same collector in Rapid City and a simple home-made collector in the laboratory. The home-made collector consists of a brass-copper plate sprayed with flat-black paint, covered with glass sheets and boxed with two inch thick styrofoam insulation. A cooling as much as 10 C in winter has been observed. It is expected to be appreciably more in summer. This suggests a potential utilization of nocturnal radiation for air conditioning. Theoretical analysis is presented.

  11. Evacuation transportation management : task four: interview and survey results.

    Science.gov (United States)

    2006-06-26

    Much of what is known about evacuations is based on preparations for incidents, such as hurricanes, for which there is advance warning. With advance warning, evacuations can be planned and managed using procedures and systems that have been developed...

  12. Mobile Collector for Field Trips

    Directory of Open Access Journals (Sweden)

    Lucia Terrenghi

    2004-04-01

    Full Text Available Current e-Learning is based on learning management systems that provide certain standard services - course authoring and delivery, tutoring, administration and collaboration facilities. Rapid development of mobile technologies opens a new area of m-Learning to enhance the current educational opportunities. Field trips are a relevant part of the curriculum, but for various reasons it is often difficult to organize them. The aim of the RAFT project is development of a system that would enable virtual field trips. One mobile learning application prototype created in this project, called Mobile Collector, enables data gathering and annotation in the field, together with real time collaboration. The application supports learner-centred education in real world context.

  13. Thermal efficiency of low cost solar collectors - CSBC; Eficiencia termica de coletores solares de baixo custo - CSBC

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Renato C.; Shiota, Robson T.; Mello, Samuel F.; Assis Junior, Valdir; Bartoli, Julio R. [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Faculdade de Engenharia Quimica. Dept. de Tecnologia de Polimeros

    2006-07-01

    The thermal performance of a low cost flat panel solar collector was measured. This Low Cost Solar Collector is a novel concept for water heating using only thermoplastics materials, used on building: ceiling and tubes made of unplasticized PVC, but without transparent cover. The top side of the UPVC panel was black painted to be the solar radiation absorber surface. Prototypes were installed on two charity houses around Campinas and at the FEQ campus, being used without any trouble for one year. The thermal efficiency analysis followed ABNT NBR 10184 standard at the Green-Solar Laboratory, Brazilian Centre for Development of Solar Thermal Energy, PUC-Minas. It was measured a thermal efficiency of 67%, compared to the 75% usually found on conventional solar collectors made of copper tubes and with glass cover. (author)

  14. Design and beam transport simulations of a multistage collector for the Israeli EA-FEM

    CERN Document Server

    Tecimer, M; Efimov, S; Gover, A; Sokolowski, J

    2001-01-01

    A four stage asymmetric type depressed collector has been designed for the Israeli mm-wave FEM that is driven by a 1.4 MeV, 1.5 A electron beam. After leaving the interaction section the spent beam has an energy spread of 120 keV and 75 pi mm mrad normalized beam emittance. Simulations of the beam transport system from the undulator exit through the decelerator tube into the collector have been carried out using EGUN and GPT codes. The latter has also been employed to study trajectories of the primary and scattered particles within the collector, optimizing the asymmetrical collector geometry and the electrode potentials at the presence of a deflecting magnetic field. The estimated overall system and collector efficiencies reach 50% and 70%, respectively, with a beam recovery of 99.6%. The design is aimed to attain millisecond long pulse operation and subsequently 1 kW average power. Simulation results are implemented in a mechanical design that leads to a simple, cost efficient assembly eliminating ceramic i...

  15. Mathematical model of heat-mass exchange processes in a flat solar collector SUN 1

    Directory of Open Access Journals (Sweden)

    Tunik Aleksandr Aleksandrovich

    2016-01-01

    Full Text Available In a flat solar collector SUN 1 The active development of environmental friendly energy sources alternative to HPPs is currently of great importance in the world. Such alternative energy sources are: water, ground, sun, wind, biofuel, etc. If we have a look at the atlas of solar energy resources on the territory of Russia, we can make a conclusion, that in many regions of our country solar activity level allows using solar collector. Though the analysis of different models of solar collector showed, that most of them are ineffective in the regions with cold climate, though the solar activity of these regions is of a great level. In this regard, a mathematical model of heat-mass exchange processes in flat solar collectors is introduced in this article. The model was a basis for the development of a new solar collector, named SUN 1, which has an original heating tubes form. This form allows heat transfer medium to be under the influence of solar energy for a longer time and consequently to warm to a higher temperature, increasing the warming rapidity.

  16. Uncertainty in a spatial evacuation model

    Science.gov (United States)

    Mohd Ibrahim, Azhar; Venkat, Ibrahim; Wilde, Philippe De

    2017-08-01

    Pedestrian movements in crowd motion can be perceived in terms of agents who basically exhibit patient or impatient behavior. We model crowd motion subject to exit congestion under uncertainty conditions in a continuous space and compare the proposed model via simulations with the classical social force model. During a typical emergency evacuation scenario, agents might not be able to perceive with certainty the strategies of opponents (other agents) owing to the dynamic changes entailed by the neighborhood of opponents. In such uncertain scenarios, agents will try to update their strategy based on their own rules or their intrinsic behavior. We study risk seeking, risk averse and risk neutral behaviors of such agents via certain game theory notions. We found that risk averse agents tend to achieve faster evacuation time whenever the time delay in conflicts appears to be longer. The results of our simulations also comply with previous work and conform to the fact that evacuation time of agents becomes shorter once mutual cooperation among agents is achieved. Although the impatient strategy appears to be the rational strategy that might lead to faster evacuation times, our study scientifically shows that the more the agents are impatient, the slower is the egress time.

  17. Evacuating the Area of a Hurricane

    Centers for Disease Control (CDC) Podcasts

    2006-08-10

    If a hurricane warning is issued for your area, or authorities tell you to evacuate, take only essential items. If you have time, turn off gas, electricity, and water and disconnect appliances.  Created: 8/10/2006 by Emergency Communications System.   Date Released: 10/10/2007.

  18. Evacuation dynamics of asymmetrically coupled pedestrian pairs

    CERN Document Server

    Müller, Frank

    2016-01-01

    We propose and analyze extended floor field cellular automaton models for evacuation dynamics of inhomogeneous pedestrian pairs which are coupled by asymmetric group interactions. Such pairs consist of a leader, who mainly determines the couple's motion and a follower, who has a defined tendency to follow the leader. Examples for such pairs are mother and child or two siblings of different age. We examine the system properties and compare them to the case of a homogeneous crowd. We find a strong impact on evacuation times for the regime of strong pair coupling due to the occurrence of a clogging phenomenon. In addition we obtain a non-trivial dependence of evacuation times on the followers' coupling to the static floor field, which carries the information of the shortest way to the exit location. In particular we find that systems with fully passive followers, who are solely coupled to their leaders, show lower evacuation times than homogeneous systems where all pedestrians have an equal tendency to move towa...

  19. An adaptive simulation tool for evacuation scenarios

    NARCIS (Netherlands)

    Formolo, Daniel; van der Wal, C. Natalie

    2017-01-01

    Building useful and efficient models and tools for a varied audience, such as evacuation simulators for scientists, engineers and crisis managers, can be tricky. Even good models can fail in providing information when the user’s tools for the model are scarce of resources. The aim of this work is to

  20. COMPARATIVE FIELD EXPERIMENTAL INVESTIGATIONS OF DIFFERENT FLAT PLATE SOLAR COLLECTORS

    Directory of Open Access Journals (Sweden)

    Guangming Chen

    2015-12-01

    Full Text Available Full-scale traditional metal solar collectors and solar collector specimens fabricated from polymeric materials were investigated in the present study. A polymeric collector is 67.8% lighter than a traditional metal solar collector, and a metal solar collector with transparent plastic covering is 40.3% lighter than a traditional metal solar collector. Honeycomb multichannel plates made from polycarbonate were chosen to create a polymeric solar collector. A test rig for the natural circulation of the working fluid in a solar collector was built for a comparative experimental investigation of various solar collectors operating at ambient conditions. It was shown experimentally that the efficiency of a polymeric collector is 8–15% lower than the efficiency of a traditional collector.

  1. The Pedestrian Evacuation Analyst: geographic information systems software for modeling hazard evacuation potential

    Science.gov (United States)

    Jones, Jeanne M.; Ng, Peter; Wood, Nathan J.

    2014-01-01

    Recent disasters such as the 2011 Tohoku, Japan, earthquake and tsunami; the 2013 Colorado floods; and the 2014 Oso, Washington, mudslide have raised awareness of catastrophic, sudden-onset hazards that arrive within minutes of the events that trigger them, such as local earthquakes or landslides. Due to the limited amount of time between generation and arrival of sudden-onset hazards, evacuations are typically self-initiated, on foot, and across the landscape (Wood and Schmidtlein, 2012). Although evacuation to naturally occurring high ground may be feasible in some vulnerable communities, evacuation modeling has demonstrated that other communities may require vertical-evacuation structures within a hazard zone, such as berms or buildings, if at-risk individuals are to survive some types of sudden-onset hazards (Wood and Schmidtlein, 2013). Researchers use both static least-cost-distance (LCD) and dynamic agent-based models to assess the pedestrian evacuation potential of vulnerable communities. Although both types of models help to understand the evacuation landscape, LCD models provide a more general overview that is independent of population distributions, which may be difficult to quantify given the dynamic spatial and temporal nature of populations (Wood and Schmidtlein, 2012). Recent LCD efforts related to local tsunami threats have focused on an anisotropic (directionally dependent) path distance modeling approach that incorporates travel directionality, multiple travel speed assumptions, and cost surfaces that reflect variations in slope and land cover (Wood and Schmidtlein, 2012, 2013). The Pedestrian Evacuation Analyst software implements this anisotropic path-distance approach for pedestrian evacuation from sudden-onset hazards, with a particular focus at this time on local tsunami threats. The model estimates evacuation potential based on elevation, direction of movement, land cover, and travel speed and creates a map showing travel times to safety (a

  2. FIRE EVACUATION FROM HIGH-RISE BUILDINGS

    Directory of Open Access Journals (Sweden)

    Korol'chenko Aleksandr Yakovlevich

    2012-10-01

    Full Text Available The authors argue that no collapse of structures is likely in the event of a fire emergency in multistoried buildings, rather, other fire-related factors may endanger the lives of people inside high-rise buildings exposed to the fire emergency, including open fire, sparks, high ambient temperature, smoke and toxic combustion products, reduced concentration of oxygen, and combined influence of various factors. In case of fire, the temperature inside buildings reaches 1100 °С. It exceeds the temperature of the ambient air acceptable for humans by far (70 °С. The experiments demonstrate that combustion products contain hundreds of toxic chemical compounds. The most hazardous of them include carbon oxide, carbon dioxide, chloride and cyanic hydrogen, aldehydes and acrolein. The author provides the pattern of their influence on the human body. The smoke consists of unburned particles of carbon and aerosols. The size of particles fluctuates within 0.05-50 MMK. Smoke produces a physiological and psychological impact on human beings. It has been proven that dangerous fire factors emerge within the first five to ten minutes of the emergency situation. Evacuation is the principal method of safety assurance. However, the velocity of propagation of smoke and heat is so high that even if the fire prevention system is in operation, people may be blocked both on the floors that are exposed to the fire and those that escape its propagation. New evacuation and rescue methods are recommended by the author. Various ways and methods of use of life-saving facilities are also provided. Safe evacuation is feasible from buildings where the number of stories does not exceed 10- 12. During evacuation, high density human streams are formed inside buildings, therefore, the period of stay in a burning building is increased. The calculations have proven that a two-minute delay of evacuation converts into a safe evacuation of only 13-15% of people. Low reliability of

  3. Evacuation of children - movement on stairs and on Horizontal Plane

    DEFF Research Database (Denmark)

    Larusdottir, Aldis Run; Dederichs, Anne

    2012-01-01

    Little is known on the evacuation characteristics of children. Current literature on evacuation is based mostly on studies on adults. The aim of this study is to investigate the movement of children during evacuation, focusing on flow, densities and walking. Ten Danish daycare centers participated...

  4. 21 CFR 888.4220 - Cement monomer vapor evacuator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cement monomer vapor evacuator. 888.4220 Section... (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4220 Cement monomer vapor evacuator. (a) Identification. A cement monomer vapor evacuator is a device intended for use during surgery to contain or remove...

  5. 21 CFR 876.4370 - Gastroenterology-urology evacuator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gastroenterology-urology evacuator. 876.4370... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4370 Gastroenterology-urology evacuator. (a) Identification. A gastroenterology-urology evacuator is a device used to remove...

  6. EXPERIMENTAL RESEARCH OF THE INFLUENCE OF VARIOUS TYPES OF SOLAR COLLECTORS FOR PERFORMANCE SOLAR DESALINATION PLANT

    Directory of Open Access Journals (Sweden)

    Rakhmatulin I.R.

    2014-04-01

    Full Text Available The article discusses the possibility of using renewable energy for water purification. Results of analysis of a preferred energy source for a water purification using installed in places where fresh water shortages and a lack of electrical energy. The possibility of desalination of salt water using solar energy for regions with temperate climate. Presented desalination plant working on energy vacuum solar collectors, principles of action developed by the desalination plant. The experimental results of a constructed distiller when working with vacuum glass tubes and vacuum tubes with copper core inside. Conclusions about the possibility of using solar collectors for water desalination, are tips and tricks to improve the performance of solar desalination plant.

  7. Efficiency enhancement of octave-bandwidth TWT's by the use of multistage depressed collectors

    Science.gov (United States)

    Ramins, P.; Fox, T. A.

    1977-01-01

    A small size two and four stage depressed collector was evaluated in conjunction with a 4.8 to 9.6 GHz traveling wave tube of 325 to 675 W power output. In spite of large fixed traveling wave tube losses, very significant efficiency enhancement was demonstrated with both the two and four stage multistage depressed collectors (MDC). The improvement in the overall efficiency ranged from a factor of 2.5 to 3.0 for the two stage MDC and a factor of 3.0 to 3.5 for the four stage MDC. An overall efficiency of 37.0 to 44.3 percent across the frequency band was demonstrated with the use of harmonic injection.

  8. Variations in population exposure and evacuation potential to multiple tsunami evacuation phases on Alameda and Bay Farm Islands, California

    Science.gov (United States)

    Peters, J.

    2015-12-01

    Planning for a tsunami evacuation is challenging for California communities due to the variety of earthquake sources that could generate a tsunami. A maximum tsunami inundation zone is currently the basis for all tsunami evacuations in California, although an Evacuation Playbook consisting of specific event-based evacuation phases relating to flooding severity is in development. We chose to investigate the Evacuation Playbook approach for the island community of Alameda, CA since past reports estimated a significant difference in numbers of residents in the maximum inundation zone when compared to an event-based inundation zone. In order to recognize variations in the types of residents and businesses within each phase, a population exposure analysis was conducted for each of the four Alameda evacuation phases. A pedestrian evacuation analysis using an anisotropic, path distance model was also conducted to understand the time it would take for populations to reach high ground by foot. Initial results suggest that the two islands of the City of Alameda have different situations when it comes to the four tsunami evacuation phases. Pedestrian evacuation results suggest that Bay Farm Island would have more success evacuating by vehicle due to limited nearby high ground for pedestrians to reach safety. Therefore, agent-based traffic simulation software was used to model vehicle evacuation off Bay Farm Island. Initial results show that Alameda Island could face challenges evacuating numerous boat docks and a large beach for phases 1 and 2, whereas Bay Farm Island is unaffected at these phases but might be challenged with evacuating by vehicle for phases 3 and maximum due to congestion on limited egress routes. A better understanding of the population exposure within each tsunami Evacuation Playbook phase and the time it would take to evacuate out of each phase by foot or vehicle will help emergency managers implement the evacuation phases during an actual tsunami event.

  9. Next Generation Solar Collectors for CSP

    Energy Technology Data Exchange (ETDEWEB)

    Molnar, Attila [3M Company, St. Paul, MN (United States); Charles, Ruth [3M Company, St. Paul, MN (United States)

    2014-07-31

    The intent of “Next Generation Solar Collectors for CSP” program was to develop key technology elements for collectors in Phase 1 (Budget Period 1), design these elements in Phase 2 (Budget Period 2) and to deploy and test the final collector in Phase 3 (Budget Period 3). 3M and DOE mutually agreed to terminate the program at the end of Budget Period 1, primarily due to timeline issues. However, significant advancements were achieved in developing a next generation reflective material and panel that has the potential to significantly improve the efficiency of CSP systems.

  10. Baghouse and cartridge dust collectors: A comparison

    Energy Technology Data Exchange (ETDEWEB)

    Grafe, T.; Kelley, G. (Torit and Day, Minneapolis, MN (United States))

    1993-09-01

    Increased demands are being placed on air filtration systems. The particular application will determine whether a baghouse or cartridge type is best. Baghouse and cartridge dust collectors both have their place in modern air filtering systems. Baghouses have been in use much longer, but cartridge types offer significant advantages for particular applications. The task facing the site engineer is to match the requirements of the specific application with the inherent characteristics of the dust collector. This article presents basic information about both types of dust collectors that can help provide the best solution to that problem.

  11. A thermal comparison among several beverage can solar collectors.

    Science.gov (United States)

    Peter Y.S. Chen

    1984-01-01

    Four air-heated solar collectors were built using four different configurations of aluminum beverage cans. The collectors were then tested for four consecutive seasons for their daily efficiencies. One of the collectors was also evaluated for one season for the effect of air velocity on efficiency, temperature rise, and power consumption of the collector.

  12. Performance after weathering of a liquid solar collector

    Science.gov (United States)

    1979-01-01

    Results from retesting of liquid solar collector described in "Performance evaluation of liquid collector" (M-FS-23931), after long term exposure to natural weathering indicate no detectable degradation in collector performance and no visable deterioration in appearance of collector. Supporting data and pretest/post test efficiency comparison are included.

  13. Collector/Receiver Characterization (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2010-08-01

    Fact sheet describing NREL CSP Program capabilities for collector/receiver characterization: determining optical efficiency, measuring heat loss, developing and testing concentrators, concentrating the sun's power, and optically characterizing CSP plants.

  14. Certification of the concentrating solar collector

    Science.gov (United States)

    1980-01-01

    Report describes procedures and results of extensive testing of concentrating solar collector performed for certification of systems compliance with government performance standards. Test includes operational, electrical, mechanical, and thermal checks, as well as structural integrity.

  15. Tilt assembly for tracking solar collector assembly

    Science.gov (United States)

    Almy, Charles; Peurach, John; Sandler, Reuben

    2012-01-24

    A tilt assembly is used with a solar collector assembly of the type comprising a frame, supporting a solar collector, for movement about a tilt axis by pivoting a drive element between first and second orientations. The tilt assembly comprises a drive element coupler connected to the drive element and a driver, the driver comprising a drive frame, a drive arm and a drive arm driver. The drive arm is mounted to the drive frame for pivotal movement about a drive arm axis. Movement on the drive arm mimics movement of the drive element. Drive element couplers can extend in opposite directions from the outer portion of the drive arm, whereby the assembly can be used between adjacent solar collector assemblies in a row of solar collector assemblies.

  16. Study on Earthquake Emergency Evacuation Drill Trainer Development

    Science.gov (United States)

    ChangJiang, L.

    2016-12-01

    With the improvement of China's urbanization, to ensure people survive the earthquake needs scientific routine emergency evacuation drills. Drawing on cellular automaton, shortest path algorithm and collision avoidance, we designed a model of earthquake emergency evacuation drill for school scenes. Based on this model, we made simulation software for earthquake emergency evacuation drill. The software is able to perform the simulation of earthquake emergency evacuation drill by building spatial structural model and selecting the information of people's location grounds on actual conditions of constructions. Based on the data of simulation, we can operate drilling in the same building. RFID technology could be used here for drill data collection which read personal information and send it to the evacuation simulation software via WIFI. Then the simulation software would contrast simulative data with the information of actual evacuation process, such as evacuation time, evacuation path, congestion nodes and so on. In the end, it would provide a contrastive analysis report to report assessment result and optimum proposal. We hope the earthquake emergency evacuation drill software and trainer can provide overall process disposal concept for earthquake emergency evacuation drill in assembly occupancies. The trainer can make the earthquake emergency evacuation more orderly, efficient, reasonable and scientific to fulfill the increase in coping capacity of urban hazard.

  17. Pet Ownership and Evacuation Prior to Hurricane Irene

    Directory of Open Access Journals (Sweden)

    Nick Rohrbaugh

    2012-09-01

    Full Text Available Pet ownership has historically been one of the biggest risk factors for evacuation failure prior to natural disasters. The forced abandonment of pets during Hurricane Katrina in 2005 made national headlines and led to the passage of the Pet Evacuation and Transportation Standards Act (PETS, 2006 which mandated local authorities to plan for companion animal evacuation. Hurricane Irene hit the East Coast of the United States in 2011, providing an excellent opportunity to examine the impact of the PETS legislation on frequency and ease of evacuation among pet owners and non-pet owners. Ninety pet owners and 27 non-pet owners who lived in mandatory evacuation zones completed questionnaires assessing their experiences during the hurricane and symptoms of depression, PTSD, dissociative experiences, and acute stress. Pet ownership was not found to be a statistical risk factor for evacuation failure. However, many pet owners who failed to evacuate continue to cite pet related reasons.

  18. Intelligent Transportation and Evacuation Planning A Modeling-Based Approach

    CERN Document Server

    Naser, Arab

    2012-01-01

    Intelligent Transportation and Evacuation Planning: A Modeling-Based Approach provides a new paradigm for evacuation planning strategies and techniques. Recently, evacuation planning and modeling have increasingly attracted interest among researchers as well as government officials. This interest stems from the recent catastrophic hurricanes and weather-related events that occurred in the southeastern United States (Hurricane Katrina and Rita). The evacuation methods that were in place before and during the hurricanes did not work well and resulted in thousands of deaths. This book offers insights into the methods and techniques that allow for implementing mathematical-based, simulation-based, and integrated optimization and simulation-based engineering approaches for evacuation planning. This book also: Comprehensively discusses the application of mathematical models for evacuation and intelligent transportation modeling Covers advanced methodologies in evacuation modeling and planning Discusses principles a...

  19. Pet Ownership and Evacuation Prior to Hurricane Irene.

    Science.gov (United States)

    Hunt, Melissa G; Bogue, Kelsey; Rohrbaugh, Nick

    2012-09-28

    Pet ownership has historically been one of the biggest risk factors for evacuation failure prior to natural disasters. The forced abandonment of pets during Hurricane Katrina in 2005 made national headlines and led to the passage of the Pet Evacuation and Transportation Standards Act (PETS, 2006) which mandated local authorities to plan for companion animal evacuation. Hurricane Irene hit the East Coast of the United States in 2011, providing an excellent opportunity to examine the impact of the PETS legislation on frequency and ease of evacuation among pet owners and non-pet owners. Ninety pet owners and 27 non-pet owners who lived in mandatory evacuation zones completed questionnaires assessing their experiences during the hurricane and symptoms of depression, PTSD, dissociative experiences, and acute stress. Pet ownership was not found to be a statistical risk factor for evacuation failure. However, many pet owners who failed to evacuate continue to cite pet related reasons.

  20. Interference filters for colored glazed thermal solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, A.; Roecker, C.; Scartezzini, J.-L. [Swiss Federal Institute of Technology EPFL, Laboratoire d' Energie Solaire et de Physique du Batiment LESO-PB, Lausanne (Switzerland); Boudaden, J.; Videnovic, I. R.; Ho, R. S-C.; Oelhafen, P. [Institut fuer Physik der Universitaet Basel, Basel (Switzerland)

    2003-07-01

    Glazed thermal solar collectors, typically equipped with black, optical selective absorber sheets, exhibit good energy conversion efficiency. However, the black color, and sometimes the visibility of tubes and corrugations of the metal sheets, limit the architectural integration into buildings. In order to overcome this drawback, interference filters are considered as a promising approach. Multilayered thin film stacks deposited on the cover glass can produce a colored reflection hiding the black absorber without a great loss of energy. These interference filters are designed and optimized by numerical simulation. Such coatings can be deposited by vacuum processes (e.g. magnetron sputtering) or via the SolGel method. Optical measurements, such as spectrophotometry or ellipsometry, are used to determine film thicknesses and optical constants of individual layers, and to measure color coordinates and solar transmission for the multilayer stacks. (authors)

  1. Thermomechanical Assessment of the Collector for the Hollow Electron Lens

    CERN Document Server

    Anderson, George Bowers

    2017-01-01

    The hollow electron lens (HEL) is a system proposed for the High Luminosity upgrade of the Large Hadron Collider LHC (HL-LHC) [1]. Being considered for installation at LHC point 4, the HEL improves halo control and collimation of proton beams in the collider [2]. This is achieved by creating a hollow tube of electrons using an electron gun. This axisymmetric electron cloud travels around the proton beam for a few meters, overlapping with the proton beam halo, until the electron cloud is dissipated in a collector, which is the focus of this project. A 3D image of the HEL system is found in Figure 1 and a further technical description of such electron lenses is available in [3].

  2. Wind loading on solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Bhaduri, S.; Murphy, L.M.

    1985-06-01

    The present design methodology for the determination of wind loading on the various solar collectors has been reviewed and assessed. The total force coefficients of flat plates of aspect ratios 1.0 and 3.0, respectively, at various angles of attack obtained by using the guidelines of the ANSI A58.1-1982, have been compared with those obtained by using the methodology of the ASCE Task Committee, 1961, and the experimental results of the full-scale test of heliostats by Peglow. The turbulent energy spectra, currently employed in the building code, are compared with those of Kaimal et al., Lumley, and Ponofsky for wind velocities of 20.0 m/s and 40.24 m/s at an elevation of 9.15 m. The longitudinal spectra of the building code overestimates the Kaimal spectra in the frequency range of 0.007 Hz to 0.08 Hz and underestimates beyond the frequency of 0.08 Hz. The peak angles of attack, on the heliostat, stowed in horizontal position, due to turbulent vertical and lateral components of wind velocity, have been estimated by using Daniel's methodology for three wind velocities and compared with the value suggested by the code. The experimental results of a simple test in the laboratory indicate the feasibility of decreasing the drag forces of the flat plate by reducing the solidity ratio.

  3. Local Reasoning about a Copying Garbage Collector

    DEFF Research Database (Denmark)

    Torp-Smith, Noah; Birkedal, Lars; Reynolds, John C.

    2008-01-01

    We present a programming language, model, and logic appropriate for implementing and reasoning about a memory management system. We state semantically what is meant by correctness of a copying garbage collector, and employ a variant of the novel separation logics to formally specify partial...... correctness of Cheney’s copying garbage collector in our program logic. Finally, we prove that our implementation of Cheney’s algorithm meets its specification using the logic we have given and auxiliary variables. Udgivelsesdato: 2008...

  4. Evaluation of combined photovoltaic/thermal collectors

    Energy Technology Data Exchange (ETDEWEB)

    Hendrie, S.D.

    1979-01-01

    The thermal and electric performance of an air and a liquid type combined photovoltaic/thermal solar collector has been evaluated, yielding close correlation with theoretical results. Maximum thermal efficiencies of 42.5% and 40% for the liquid and air collectors without electric power production decreased to 40.4% and 32.9% when electrical power was produced. Maximum electrical efficiencies of 6.8% were measured.

  5. Development of Magneto-static Solver Module for the design of compact and light-weight Traveling Wave Tubes

    Science.gov (United States)

    Mercy Latha, A.; Srivastav, V.; Gupta, R. K.; Ghosh, S. K.

    2012-11-01

    Traveling Wave Tubes are the unique class of microwave amplifiers with broad bandwidth, which makes it preferred for space applications. The constraints for a space application are very stringent demanding compactness and less weight. Entire size of the tube is mainly decided by the size of the collector, as it is the bulkiest component in a tube. Hence, if the size of the collector is reduced then the entire tube size will reduce. Researches reveal that in order to reduce the size of the collector, application of the magnetic field is necessary. Therefore, to study the effect of magnetic field on the collector performance, a magneto-static solver module has been developed. This paper describes the development of the magneto-static solver.

  6. Are the dynamics of gastric evacuation of natural prey in a piscivorous flatfish different from what is going on in a gadoid?

    DEFF Research Database (Denmark)

    Krog, C.; Andersen, Niels Gerner

    2009-01-01

    Despite the fact that the stomach of turbot Psetta maxima is a curved tube that forms a half circle, it was demonstrated that gastric evacuation in this predatory flatfish fed natural prey closely followed the surface-dependent cylinder model developed from studies on gadoids with a straight...

  7. Health ramifications of the Gush Katif evacuation.

    Science.gov (United States)

    Kory, Ronen; Carney, Alon; Naimer, Sody

    2013-03-01

    Following the 2005 evacuation of Gush Katif, a community of Jewish settlements located in the greater Gaza Strip, many evacuees reported a deterioration in their health status. To determine if and to what degree the evacuation of Gush Katif caused a worsening in the health status of the evacuees. In this retrospective cohort study we assessed the medical records of 2962 evacuees for changes in prevalence of diabetes, hypertension and ischemic heart disease in the period beginning 1 year before and ending 5 years after the evacuation. The findings were compared to those for the general israeli population. A questionnaire was distributed to 64 individuals to assess lifestyle and social change. An increase in diabetes and hypertension was found in men aged 45-64. The prevalence of diabetes mellitus in the 45-54 male group rose from 8.7% in 2004 to 12.6% in 2007 to 18.7% in 2010; in the 55-64 age group it rose from 24.6% in 2004 to 29.9% in 2007 to 32.9% in 2010. Hypertension in 45-64 year old men rose from 27.1% in 2004 to 35.12% in 2010. The increases in diabetes were significant and higher than those in the general population. The increases in hypertension were of similar magnitude. The prevalence of heart disease did not change and is similar to that in the general population. The questionnaire sample showed an increase in depression and overweight. The Gush Katif evacuation appears to be associated with increased morbidity of chronic disease. This may be attributed to any of several mechanisms, with unemployment, depression, inactivity and overweight playing significant roles. Preventive medical interventions and measures should be employed to screen and treat this population which underwent a major stressful event and as a result seem at greater risk than their peers.

  8. Evacuation Dynamics: Empirical Results, Modeling and Applications

    OpenAIRE

    Schadschneider, Andreas; Klingsch, Wolfram; Kluepfel, Hubert; Kretz, Tobias; Rogsch, Christian; Seyfried, Armin

    2008-01-01

    This extensive review was written for the ``Encyclopedia of Complexity and System Science'' (Springer, 2008) and addresses a broad audience ranging from engineers to applied mathematicians, computer scientists and physicists. It provides an extensive overview of various aspects of pedestrian dynamics, focussing on evacuation processes. First the current status of empirical results is critically reviewed as it forms the basis for the calibration of models needed for quantitative predictions. T...

  9. Evacuation exercise at the CERN Kindergarten

    CERN Document Server

    2001-01-01

    Every year fire evacuation exercises are organized through out CERN and our facility's Kindergarten is no exception. Just a few weeks ago, a fire simulation was carried out in the Kindergarten kitchen facility using synthetic smoke. The purpose of the exercise was to teach staff to react in a disciplined and professional manner when in the presence of danger. The simulation is always carried out at a random time so as to ensure that people in the area under the test are not aware of the exercise. For the Kindergarten the exercise was held early in the school year so as to train those who are new to the establishment. The evacuation was a complete success and all went as it was supposed to. When the children and teachers smelt smoke they followed the prescribed evacuation routes and left the building immediately. Once outside the situation was revealed as an exercise and everyone went back to business as usual, everyone that is, except the fire brigade and fire inspector. The fire brigade checked that the buil...

  10. Effects of evacuation assistant’s leading behavior on the evacuation efficiency: Information transmission approach

    Science.gov (United States)

    Wang, Xiao-Lu; Guo, Wei; Zheng, Xiao-Ping

    2015-07-01

    Evacuation assistants are expected to spread the escape route information and lead evacuees toward the exit as quickly as possible. Their leading behavior influences the evacuees’ movement directly, which is confirmed to be a decisive factor of the evacuation efficiency. The transmission process of escape information and its function on the evacuees’ movement are accurately presented by the proposed extended dynamic communication field model. For evacuation assistants and evacuees, their sensitivity parameter of static floor field (SFF), , and , are fully discussed. The simulation results indicate that the appropriate is associated with the maximum of evacuees. The optimal combinations of and were found to reach the highest evacuation efficiency. There also exists an optimal value for evacuation assistants’ information transmission radius. Project supported by the National Basic Research Program of China (Grant No. 2011CB706900), the National Natural Science Foundation of China (Grant Nos. 71225007 and 71203006), the National Key Technology Research and Development Program of the Ministry of Science and Technology of China (Grant No. 2012BAK13B06), the Humanities and Social Sciences Project of the Ministry of Education of China (Grant Nos. 10YJA630221 and 12YJCZH023), and the Beijing Philosophy and Social Sciences Planning Project of the Twelfth Five-Year Plan, China (Grant Nos. 12JGC090 and 12JGC098).

  11. Influence of collector heat capacity and internal conditions of heat exchanger on cool-down process of small gas liquefier

    Science.gov (United States)

    Saberimoghaddam, Ali; Bahri Rasht Abadi, Mohammad Mahdi

    2018-01-01

    Joule-Thomson cooling systems are commonly used in gas liquefaction. In small gas liquefiers, transient cool-down time is high. Selecting suitable conditions for cooling down process leads to decrease in time and cost. In the present work, transient thermal behavior of Joule-Thomson cooling system including counter current helically coiled tube in tube heat exchanger, expansion valve, and collector was studied using experimental tests and simulations. The experiments were performed using small gas liquefier and nitrogen gas as working fluid. The heat exchanger was thermally studied by experimental data obtained from a small gas liquefier. In addition, the simulations were performed using experimental data as variable boundary conditions. A comparison was done between presented and conventional methods. The effect of collector heat capacity and convection heat transfer coefficient inside the tubes on system performance was studied using temperature profiles along the heat exchanger.

  12. Multimode Traveling-Wave Amplifier Tubes

    Science.gov (United States)

    Buck, E.

    1981-02-01

    The paper examines the recent developments which makes the Traveling Wave Tube (TWT) more powerful and efficient as a microwave amplifier than the solid state devices. Basic workings and efficiency, which can run, but usually do not, to 55%, are examined. The dependence of the performance of a given TWT upon the qualities of the beam and the manner of its focusing is described. Also described is the development of a multistage depressed collector (MDC) and its first application to a Communication Technology Satellite (CTS) tube, a 12 GHz, coupled-cavity, 200 watt TWT, which resulted in being operated in space for nearly four years and was both the most powerful and the most efficient (around 50%) communications TWT ever flown. It is predicted that the application of efficient refocusing and MDCs, made possible by computer simulations, will greatly increase tube efficiency, and thereby make practical, new multimode tubes which operate, as least partly, in a linear fashion.

  13. Dual effects of guide-based guidance on pedestrian evacuation

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Yi, E-mail: yima23-c@my.cityu.edu.hk; Lee, Eric Wai Ming; Shi, Meng

    2017-06-15

    This study investigates the effects of guide-based guidance on the pedestrian evacuation under limited visibility via the simulations based on an extended social force model. The results show that the effects of guides on the pedestrian evacuation under limited visibility are dual, and related to the neighbor density within the visual field. On the one hand, in many cases, the effects of guides are positive, particularly when the neighbor density within the visual field is moderate; in this case, a few guides can already assist the evacuation effectively and efficiently. However, when the neighbor density within the visual field is particularly small or large, the effects of guides may be adverse and make the evacuation time longer. Our results not only provide a new insight into the effects of guides on the pedestrian evacuation under limited visibility, but also give some practical suggestions as to how to assign guides to assist the evacuation under different evacuation conditions. - Highlights: • Extended social force model is used to simulate guided pedestrian evacuation. • Effects of guides on pedestrian evacuation under limited visibility are dual. • Effects of guides on pedestrian evacuation under limited visibility are related to neighbor density within visual field.

  14. A New Models for Emergency Evacuation under the Disaster Condition

    Science.gov (United States)

    Tang, L.; Yang, X.; Huang, F.; Xu, H.; Li, Q.

    2012-07-01

    People must face many disasters every day, which cause losses in property and human lives. It is significant how to establish the emergency evacuation model and for high density population in large areas according to the actual situation of their emergency evacuation. This paper put forward a Multi-levels Emergency Evacuation Model (MEE) based on the collective evacuation for high density of population in large areas under the earthquake condition in China, which firstly find the best ways from the multi-gathering points(Origins) in the disaster area to multi-settling points(Destinations )in the safe area based on the road impedance such as the traffic, road speed limit and pavement damage to weight the evacuation ability of road network, and secondly determine the evacuation auto numbers on the every routes which is at the target to deliver all the evacuating people from the Origins to Destinations in the shortest time. The experiment area is Dezhou city in Shandong province of China, and an emergency evacuation platform was put up according to the multilevel emergency evacuation model using Google map API and C# as development platform, and the result show us that MEE is promised to be a new methods for emergency evacuation.

  15. Optimization of Evacuation Warnings Prior to a Hurricane Disaster

    Directory of Open Access Journals (Sweden)

    Dian Sun

    2017-11-01

    Full Text Available The key purpose of this paper is to demonstrate that optimization of evacuation warnings by time period and impacted zone is crucial for efficient evacuation of an area impacted by a hurricane. We assume that people behave in a manner consistent with the warnings they receive. By optimizing the issuance of hurricane evacuation warnings, one can control the number of evacuees at different time intervals to avoid congestion in the process of evacuation. The warning optimization model is applied to a case study of Hurricane Sandy using the study region of Brooklyn. We first develop a model for shelter assignment and then use this outcome to model hurricane evacuation warning optimization, which prescribes an evacuation plan that maximizes the number of evacuees. A significant technical contribution is the development of an iterative greedy heuristic procedure for the nonlinear formulation, which is shown to be optimal for the case of a single evacuation zone with a single evacuee type case, while it does not guarantee optimality for multiple zones under unusual circumstances. A significant applied contribution is the demonstration of an interface of the evacuation warning method with a public transportation scheme to facilitate evacuation of a car-less population. This heuristic we employ can be readily adapted to the case where response rate is a function of evacuation number in prior periods and other variable factors. This element is also explored in the context of our experiment.

  16. Step tracking program for concentrator solar collectors

    Science.gov (United States)

    Ciobanu, D.; Jaliu, C.

    2016-08-01

    The increasing living standards in developed countries lead to increased energy consumption. The fossil fuel consumption and greenhouse gas effect that accompany the energy production can be reduced by using renewable energy. For instance, the solar thermal systems can be used in temperate climates to provide heating during the transient period or cooling during the warmer months. Most used solar thermal systems contain flat plate solar collectors. In order to provide the necessary energy for the house cooling system, the cooling machine uses a working fluid with a high temperature, which can be supplied by dish concentrator collectors. These collectors are continuously rotated towards sun by biaxial tracking systems, process that increases the consumed power. An algorithm for a step tracking program to be used in the orientation of parabolic dish concentrator collectors is proposed in the paper to reduce the consumed power due to actuation. The algorithm is exemplified on a case study: a dish concentrator collector to be implemented in Brasov, Romania, a location with the turbidity factor TR equal to 3. The size of the system is imposed by the environment, the diameter of the dish reflector being of 3 meters. By applying the proposed algorithm, 60 sub-programs are obtained for the step orientation of the parabolic dish collector over the year. Based on the results of the numerical simulations for the step orientation, the efficiency of the direct solar radiation capture on the receptor is up to 99%, while the energy consumption is reduced by almost 80% compared to the continuous actuation of the concentrator solar collector.

  17. Thermal analysis of a solar collector consisting of V cavities for water heating; Analise termica de um coletor solar composto de cavidades V para aquecimento de agua

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Michel Fabio de Souza

    2009-03-15

    The solar water heating is carried through, in Brazil, by means of solar heaters compound for collectors flat plate of the type plate-and-pipes, devices that operate in stationary position and they do not require tracking of the sun. A compound collector for some formed V-trough concentrators can be an alternative to the conventional solar collectors flat plate. This compound collector for V-trough is considered, each one, for side-walls which are specularly reflecting surfaces associates in V (equivalent to a triangular gutter). Next to the vertex to each V-trough concentrators an absorber tube is fixed, for flow of the fluid to be heated. Interconnection of the absorbers tubes forms a similar tubular network existing in solar collectors of the type the plate and pipe. V-trough concentrators with the absorbers tubes are made use in series in the interior a prismatic box, which have one of its faces consisting by a glass covering and directed toward incidence of the solar radiation. An analysis of thermal performance of these devices operating stationary and without tracking of the sun is researched. A mathematical model for the computational simulation of the optical and thermal performance of these concentrative devices is elaborated, whose implementation was carried through software EES (Engineering Equation Solver). The efficiency optics of V-trough concentrators with cylindrical absorbers is calculated from the adaptation of the methodology used for Fraidenraich (1994), proposal for Hollands (1971) for V-trough cavities with plain absorbers. The thermal analysis of the considered collector was based on the applied methodology the CPC for Hsieh (1981) and Leao (1989). Relative results to the thermal performance of V-trough concentrators suggest that these configurations are not competitive, technique and economically, with the conventional plain collectors. Although some geometric configurations presented next thermal efficiencies to the conventional plain

  18. Feeding Tubes

    Science.gov (United States)

    ... feeding therapies have been exhausted. Please review product brand and method of placement carefully with your physician ... Total Parenteral Nutrition. Resources: Oley Foundation Feeding Tube Awareness Foundation Children’s Medical Nutrition Alliance APFED’s Educational Webinar ...

  19. Optimum solar collector fluid flow rates

    DEFF Research Database (Denmark)

    Furbo, Simon; Shah, Louise Jivan

    1996-01-01

    Experiments showed that by means of a standard electronically controlled pump, type UPE 2000 from Grundfos it is possible to control the flow rate in a solar collector loop in such a way that the flow rate is strongly influenced by the temperature of the solar collector fluid passing the pump...... the energy consumption of a normal ciculation pump in the solar heating system.Calculations showed that the highest thermal performances for small SDHW systems based on mantle tanks with constant volume flow rates in the solar collector loops are achieved if the flow rate is situated in the interval from 0.......2 to 0.3 l/min. per m^2 solar collector for combi tank systems and in the interval from 0.3 to 0.4 l/min. per m^2 solar collector for preheating systems. Further, calculations showed that by means of an advanced control strategy for the flow rate - for instance if the flow rate is directly proportional...

  20. Assessment of total evacuation systems for tall buildings

    CERN Document Server

    Ronchi, Enrico

    2014-01-01

    This SpringerBrief focuses on the use of egress models to assess the optimal strategy for total evacuation in high-rise buildings. It investigates occupant relocation and evacuation strategies involving the exit stairs, elevators, sky bridges and combinations thereof. Chapters review existing information on this topic and describe case study simulations of a multi-component exit strategy. This review provides the architectural design, regulatory and research communities with a thorough understanding of the current and emerging evacuation procedures and possible future options. A model case study simulates seven possible strategies for the total evacuation of two identical twin towers linked with two sky-bridges at different heights. The authors present the layout of the building and the available egress components including both vertical and horizontal egress components, namely stairs, occupant evacuation elevators (OEEs), service elevators, transfer floors and sky-bridges. The evacuation strategies employ a ...

  1. Carbon-Nanohorn Based Nanofluids for a Direct Absorption Solar Collector for Civil Application.

    Science.gov (United States)

    Moradi, A; Sani, E; Simonetti, M; Francini, F; Chiavazzo, E; Asinari, P

    2015-05-01

    Direct solar absorption has been often considered in the past as a possible solution for solar thermal collectors for residential and small commercial applications. A direct absorption could indeed improve the performance of solar collectors by skipping one step of the heat transfer mechanism in standard devices and having a more convenient temperature distribution inside the collector. Classical solar thermal collectors have a metal sheet as absorber, designed such that water has the minimum temperature in each transversal section, in order to collect as much solar thermal energy as possible. On the other hand, in a direct configuration, the hottest part of the system is the operating fluid and this allows to have a more efficient conversion. Nanofluids, i.e., fluids with a suspension of nanoparticles, such as carbon nanohorns, could be a good and innovative family of absorbing fluids owing to their higher absorption coefficient compared to the base fluid and stability under moderate temperature gradients. Moreover, carbon nanohorns offer the remarkable advantage of a reduced toxicity over other carbon nanoparticles. In this work, a three-dimensional model of the absorption phenomena in nanofluids within a cylindrical tube is coupled with a computational fluid dynamics (CFD) analysis of the flow and temperature field. Measured optical properties of nanofluids at different concentrations have been implemented in the model. Heat losses due to conduction, convection and radiation at the boundaries are considered as well.

  2. Are the dynamics of gastric evacuation of natural prey in a piscivorous flatfish different from what is going on in a gadoid?

    Science.gov (United States)

    Krog, C; Andersen, N G

    2009-11-01

    Despite the fact that the stomach of turbot Psetta maxima is a curved tube that forms a half circle, it was demonstrated that gastric evacuation in this predatory flatfish fed natural prey closely followed the surface-dependent cylinder model developed from studies on gadoids with a straight stomach. Evacuation experiments were performed on two size groups of P. maxima fed sandeel Ammodytes tobianus as well as on P. maxima fed brown shrimp Crangon crangon at three different temperatures. This enabled the provision of a gastric evacuation model for studies on P. maxima, which takes into account the effects of the explanatory variables predator size, temperature, prey energy density and resistance of prey to the digestive processes in the stomach. Basically, the cylinder model predicts that a square-root function accurately describes gastric evacuation, which is inconsistent with the conclusion of a previous study on P. maxima that evacuation of A. tobianus is essentially linear with time. Use of the cylinder model to the values of the explanatory variables presented in the latter study, however, gave accurate predictions of the actually acquired evacuation data, which points to the generic value of the model.

  3. Efficiencies of flat plate solar collectors at different flow rates

    DEFF Research Database (Denmark)

    Chen, Ziqian; Furbo, Simon; Perers, Bengt

    2012-01-01

    Two flat plate solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one collector is equipped with an ETFE foil between...... the absorber and the cover glass and the other is without ETFE foil. The efficiencies for the collectors are tested at different flow rates. On the basis of the measured efficiencies, the efficiencies for the collectors as functions of flow rate are obtained. The calculated efficiencies are in good agreement...

  4. What is the appropriate radiation level for evacuations?

    Energy Technology Data Exchange (ETDEWEB)

    Cuttler, J.M., E-mail: jerrycuttler@rogers.com [Cuttler & Associates Inc., Mississauga, Ontario (Canada)

    2012-07-01

    This commentary reviews the international radiation protection policy that resulted in the evacuation of more than 90,000 residents from areas near the Fukushima Daiichi NPS and the enormous expenditures to protect them against a hypothetical risk of cancer. The basis for the precautionary measures is shown to be invalid; the radiation level chosen for evacuation is not conservative. The actions caused unnecessary fear and suffering. An appropriate level for evacuation is recommended. Radical changes to the ICRP recommendations are long overdue.

  5. Short-Term Solar Collector Power Forecasting

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Perers, Bengt

    2011-01-01

    This paper describes a new approach to online forecasting of power output from solar thermal collectors. The method is suited for online forecasting in many applications and in this paper it is applied to predict hourly values of power from a standard single glazed large area flat plate collector......, such as wind power. In such a scenario online forecasting is a vital tool for optimal control and utilization of solar heating systems. The method is a two-step scheme, where first a non-linear model is applied to transform the solar power into a stationary process, which then is forecasted with robust time......-adaptive linear models. The approach is similar to the one by Bacher et al. (2009), but contains additional effects due to differences between solar thermal collectors and photovoltaics. Numerical weather predictions provided by Danish Meteorological Institute are used as input. The applied models adapt over time...

  6. Evacuation routes performances and fire safety of buildings

    Directory of Open Access Journals (Sweden)

    Laban Mirjana Đ.

    2015-01-01

    Full Text Available Residential buildings, public and business facilities with large number of occupants are particularly exposed to the risk of event with catastrophic consequences, especially in case of fire. Evacuation routes must be separated fire compartments with surfaces made of non-combustible materials. Safe evacuation of building occupants in case of fire is a crucial requirement for the preservation of human life in building. In our engineering practice, calculation model is usually applied in order to determine the time required for evacuation (SRPS TP 21. However, evacuation simulation models are more present in research papers, contributing to better assessment of flow of evacuation in the real time. These models could provide an efficient way of testing the safety of a building in the face of fire and indicate critical points at the evacuation paths. Computer models enable the development and analysis of multiple various scenarios during a fire event, contributing to defining the measures for improving the safety of the building in case of fire. This paper analyses the fulfilment of technical requirements for the safe evacuation and proposes improvement measures based on a comparative analysis of the time required for occupants' evacuation from the building (Department of Civil Engineering and Geodesy in Novi Sad, obtained by calculation model and by using evacuation simulation software.

  7. Analysis of dynamic road risk for pedestrian evacuation

    Science.gov (United States)

    Zhang, Nan; Huang, Hong; Su, Boni; Zhao, Jinlong

    2015-07-01

    Knowing the dynamic road risk for pedestrian evacuation and having an efficient evacuation plan play a very important role in the serious disasters such as earthquake, tsunami and hurricane. In this paper, the dynamic road risk for pedestrian evacuation in a densely populated area of Beijing was studied with consideration of different influencing factors. Firstly, the eight influencing factors including road width, node degree, safety betweenness, road resistor coefficient, building threat, pedestrian counterflow, illegal vehicle parking and traffic flow were considered to assess the road risk for pedestrian evacuation. Secondly, based on complex network theory, electric circuit theory and real situation of the roads, the comprehensive assessment function for road risk was developed quantitatively based on the eight influencing factors. Thirdly, we analyzed road risk for pedestrian evacuation considering different situations: current condition, regular condition, and optimal condition; the risk distribution maps were drawn to directly show the risk level. Through assessments, the roads with high risk for pedestrian evacuation were found, and an optimized evacuation plan was obtained and analyzed. This mathematical model can guide the emergency evacuation in real time. The process and the results are essential for improving the efficiency of evacuations which should considerably reduce the possibility of injuries, deaths and other losses in the disaster.

  8. Study on rapid evacuation in high-rise buildings

    Directory of Open Access Journals (Sweden)

    Xin Zhang

    2017-06-01

    Full Text Available More and more high rising buildings emerged in modern cities, but emergency evacuation of tall buildings has been a worldwide difficult problem. In this paper, a new evacuation device for high rising buildings in fire accident was proposed and studied. This device mainly consisted of special spiral slideway and shunt valve. People in this device could fast slide down to the first floor under gravity without any electric power and physical strength, which is suitable for various emergency evacuation including mobility-impaired persons. The plane simulation test has shown that human being in alternative clockwise and counterclockwise movement will not become dizzy. The evacuated people should wear protection pad, which can prevent slider from being injured by surface friction with the slide, and eliminate the friction coefficient difference caused by different clothes and slide surface. The calculation results show that the evacuation speed of the new device is much faster than traditional staircases. Moreover, such new evacuation device can also be used as a means of vertical transportation in high-rise buildings partly. People can take it from any floor to ground floor directly, which not only save time for waiting for the lifts but also save the power. The new evacuation system is of simple structure, easy to use, and suitable for evacuation and partly used as vertical downwards traffic, which shows light on solving world-wide difficulties on fast evacuation in high-rise buildings.

  9. A generic framework for tsunami evacuation planning

    Science.gov (United States)

    Scheer, Stefan J.; Varela, Vassiliki; Eftychidis, George

    Tsunami preparedness is fundamentally enhanced having available a comprehensive catalogue of procedures to be applied one by one thus ensuring a fully working evacuation plan over time. All these procedures are grouped into three basic steps to be performed subsequently: a first step in order to generate a fully valid first instance of an evacuation plan, a second step needed to install and to disseminate the evacuation plan, and a third step to deploy, integrate and maintain the plan in a long-term. The application of each procedure requires input from previously applied procedures as well as other input to be obtained from scientific insights (expected wave height, expected arrival time of the first tsunami wave) obtainable through the analysis of realistic scenarios. The output of each procedure may trigger other procedures (within the current step or by going back towards a procedure of a previous step). Thus the whole methodology mirrors a nested and recursive approach. Though the whole methodology is based on the use of dedicated tools (GIS tools, simulation tools) it should also be applicable by decision makers not having available the full range of such tools. In such cases responsible stakeholders have to switch to a more qualitative approach by using some rules of thumb or just normal logical thinking. Proposing this kind of framework it clearly addresses the needs of many decision makers in the world in enhancing the tsunami preparedness in their communities. First tests along some Mediterranean communities have shown the applicability of realistic scenarios thus producing inundation and further maps with which all other procedures of this framework could subsequently be worked out.

  10. Qualification test and analysis report: solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    1978-12-01

    Test results show that the Owens-Illinois Sunpak/sup TM/ Model SEC 601 air-cooled collector meets the national standards and codes as defined in the Subsystem Performance Specification and Verification Plan of NASA/MSFC Contract NAS8-32259, dated October 28, 1976. The architectural and engineering firm of Smith, Hinchman and Grylls, Detroit, Michigan, acted in the capacity of the independent certification agency. The program calls for the development, fabrication, qualification and delivery of an air-liquid solar collector for solar heating, combined heating and cooling, and/or hot water systems.

  11. Behavior of a solar collector loop during stagnation

    DEFF Research Database (Denmark)

    Chen, Ziqian; Dragsted, Janne; Furbo, Simon

    2015-01-01

    A mathematical model simulating the emptying behavior of a pressurized solar collector loop with solar collectors with a good emptying behavior is developed and validated with measured data. The calculated results are in good agreement with the measured results. The developed simulation model...... is therefore suitable to determine the behavior of a solar collector loop during stagnation. A volume ratio R, which is the ratio of the volume of the vapour in the upper pipes of the solar collector loop during stagnation and the fluid content of solar collectors, is introduced to determine the mass...... of the collector fluid pushed into the expansion vessel during stagnation, Min. A correlation function for the mass Min and the volume ratio R for solar collector loops is obtained. The function can be used to determine a suitable size of expansion vessels for solar collector loops....

  12. Pedestrian Dynamics Feedback Control of Crowd Evacuation

    CERN Document Server

    Kachroo, Pushkin P.E; Al-nasur, Sadeq J; Shende, Apoorva

    2008-01-01

    Effective evacuation of people from closed spaces is an extremely important topic, since it can save real lives in emergency situations that can be brought about by natural and human made disasters. Usually there are static maps posted at various places at buildings that illustrate routes that should be taken during emergencies. However, when disasters happen, some of these routes might not be valid because of structural problems due to the disaster itself and more importantly because of the distribution of congestion of people spread over the area. The average flow of traffic depends on the traffic density. Therefore, if all the people follow the same route, or follow a route without knowing the congestion situation, they can end up being part of the congestion which results in very low flow rate or worse a traffic jam. Hence it becomes extremely important to design evacuations that inform people how fast and in which direction to move based on real-time information obtained about the people distribution usi...

  13. A Simulation Tool for Hurricane Evacuation Planning

    Directory of Open Access Journals (Sweden)

    Daniel J. Fonseca

    2009-01-01

    Full Text Available Atlantic hurricanes and severe tropical storms are a serious threat for the communities in the Gulf of Mexico region. Such storms are violent and destructive. In response to these dangers, coastal evacuation may be ordered. This paper describes the development of a simulation model to analyze the movement of vehicles through I-65, a major US Interstate highway that runs north off the coastal City of Mobile, Alabama, towards the State of Tennessee, during a massive evacuation originated by a disastrous event such a hurricane. The constructed simulation platform consists of a primary and two secondary models. The primary model is based on the entry of vehicles from the 20 on-ramps to I-65. The two secondary models assist the primary model with related traffic events such as car breakdowns and accidents, traffic control measures, interarrival signaling, and unforeseen emergency incidents, among others. Statistical testing was performed on the data generated by the simulation model to indentify variation in relevant traffic variables affecting the timely flow of vehicles travelling north. The performed statistical analysis focused on the closing of alternative on-ramps throughout the Interstate.

  14. Performance of Polycrystalline Photovoltaic and Thermal Collector (PVT on Serpentine-Parallel Absorbers Design

    Directory of Open Access Journals (Sweden)

    Mustofa Mustofa

    2017-03-01

    Full Text Available This paper presents the performance of an unglazed polycrystalline photovoltaic-thermal PVT on 0.045 kg/s mass flow rate. PVT combine photovoltaic modules and solar thermal collectors, forming a single device that receive solar radiation and produces heat and electricity simultaneously. The collector figures out serpentine-parallel tubes that can prolong fluid heat conductivity from morning till afternoon. During testing, cell PV, inlet and outlet fluid temperaturs were recorded by thermocouple digital LM35 Arduino Mega 2560. Panel voltage and electric current were also noted in which they were connected to computer and presented each second data recorded. But, in this performance only shows in the certain significant time data. This because the electric current was only noted by multimeter device not the digital one. Based on these testing data, average cell efficieny was about 19%, while thermal efficiency of above 50% and correspondeng cell efficiency of 11%, respectively

  15. Performance of Polycrystalline Photovoltaic and Thermal Collector (PVT on Serpentine-Parallel Absor

    Directory of Open Access Journals (Sweden)

    Mustofa

    2015-10-01

    Full Text Available This paper presents the performance of an unglazed polycrystalline photovoltaic-thermal PVT on 0.045 kg/s mass flow rate. PVT combine photovoltaic modules and solar thermal collectors, forming a single device that receive solar radiation and produces heat and electricity simultaneously. The collector figures out serpentine-parallel tubes that can prolong fluid heat conductivity from morning till afternoon. During testing, cell PV, inlet and outlet fluid temperatures were recorded by thermocouple digital LM35 Arduino Mega 2560. Panel voltage and electric current were also noted in which they were connected to computer and presented each second data recorded. But, in this performance only shows in the certain significant time data. This because the electric current was only noted by multimeter device not the digital one. Based on these testing data, average cell efficiency was about 19%, while thermal efficiency of above 50% and correspondent cell efficiency of 11%, respectively.

  16. Solar Air Collectors: How Much Can You Save?

    Science.gov (United States)

    Newburn, J. D.

    1985-04-01

    A collector efficiency curve is used to determine the output of solar air collectors based on the testing of seven solar collectors sold in Iowa. In this application the solar heater is being used as a space heater for a house. The performance of the solar air heater was analyzed and an 8% savings in energy was achieved over a one year period using two 4 x 8 collectors in a typical house.

  17. Flat plate collector performance determined experimentally with a solar simulator

    Science.gov (United States)

    Vernon, R. W.; Simon, F. F.

    1974-01-01

    The NASA is constructing a new office building at Langley Research Center that will utilize solar energy for heating and cooling. A collector technology program being conducted at Lewis will provide the basis for selecting collectors for use at Langley. The technology program includes testing collectors in an indoor facility under simulated solar radiation. Tests have been conducted on five collectors to date and performance data are presented herein.

  18. Computer simulation-based framework for transportation evacuation in major trip generator.

    Science.gov (United States)

    2009-01-01

    Since emergencies including both natural disasters and man-made incidents, are happening more and more : frequently, evacuation, especially transportation evacuation, is becoming a hot research focus in recent years. : Currently, transportation evacu...

  19. Non-tracking solar energy collector system

    Science.gov (United States)

    Selcuk, M. K. (Inventor)

    1978-01-01

    A solar energy collector system is described characterized by an improved concentrator for directing incident rays of solar energy on parallel strip-like segments of a flatplate receiver. Individually mounted reflector modules of a common asymmetrical triangular cross-sectional configuration supported for independent orientation are asymmetric included with vee-trough concentrators for deflecting incident solar energy toward the receiver.

  20. A test program for solar collectors

    Science.gov (United States)

    1980-01-01

    Rigorous environmental and performance tests qualify solar collector for use in residential solar-energy systems. Testing over 7 month period examined pressurized effects, wind and snow loading, hail damage, solar and thermal degradation, effects of pollutants, efficiency, and outgassing. Test procedures and results are summarized in tables, graphs, and text.

  1. Selective optical coatings for solar collectors

    Science.gov (United States)

    Lowery, J. R.

    1980-01-01

    For best performance, energy-absorbing surface of solar collector should be characterized by high ratio of solar absorptance to thermal emitance. Report on optical characteristics of several chemical treatments and electrodeposited coatings for metal solar-absorbing surfaces should interest designers and users of solar-energy systems. Moisture resistance of some coatings is also reported.

  2. Performance evaluation of a liquid solar collector

    Science.gov (United States)

    1979-01-01

    Report describes thermal performance and structural-load tests on commercial single glazed flat-plate solar collector with gross area of 63.5 sq ft that uses water as heat-transfer medium. Report documents test instrumentation and procedures and presents data as tables and graphs. Results are analyzed by standard data-reduction methods.

  3. 31 CFR 203.17 - Collector depositaries.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Collector depositaries. 203.17 Section 203.17 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) FISCAL SERVICE, DEPARTMENT OF THE TREASURY FINANCIAL MANAGEMENT SERVICE PAYMENT OF FEDERAL TAXES AND THE TREASURY...

  4. In situ built-up air collector with glass cover

    DEFF Research Database (Denmark)

    Kristiansen, Finn Harken; Engelmark, Jesper

    1998-01-01

    as an absorber. Efficiency and aair pressure drop were measured. The efficiency of the two air solar collectors was almost similar and at the same level as other corresponding air solar collectors. The air pressure drop was somewhat larger in the case of the solar collector where the air flows behind...

  5. Solar collector apparatus having increased energy rejection during stagnation

    Science.gov (United States)

    Moore, Stanley W.

    1983-07-12

    The disclosure relates to an active solar collector having increased energy rejection during stagnation. The collector's glazing is brought into substantial contact with absorber during stagnation to increase re-emittance and thereby to maintain lower temperatures when the collector is not in operation.

  6. Theoretical study on a solar collector loop during stagnation

    DEFF Research Database (Denmark)

    Chen, Ziqian; Dragsted, Janne; Furbo, Simon

    2010-01-01

    A mathematical model simulating the stagnation behavior of a pressurized solar collector loop with solar collectors with a good emptying behavior is developed. Based on the pre-pressure of the expansion vessel, the system filling pressure of the solar collector loop and the design of the solar co...

  7. 7 CFR 58.221 - Collectors and conveyors.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Collectors and conveyors. 58.221 Section 58.221....221 Collectors and conveyors. Collectors shall be made of stainless steel or equally noncorrosive... for cleaning and inspection. Conveyors shall be of stainless steel or equally corrosion resistant...

  8. Ear Tubes

    Science.gov (United States)

    ... of the ear drum or eustachian tube, Down Syndrome, cleft palate, and barotrauma (injury to the middle ear caused by a reduction of air pressure, ... specialist) may be warranted if you or your child has experienced repeated ... fluid in the middle ear, barotrauma, or have an anatomic abnormality that ...

  9. A social force evacuation model with the leadership effect

    Science.gov (United States)

    Hou, Lei; Liu, Jian-Guo; Pan, Xue; Wang, Bing-Hong

    2014-04-01

    When planning for the evacuation guidance, how to efficiently set the trained evacuation leaders is an important problem which has great impact on the evacuation process. This paper investigates the effect of the number and positions of evacuation leaders on the evacuation dynamics in rooms with limited visibility range. In the improved social force model, only the trained leaders exactly know the exit positions, and the others could only follow the guidance according to the positions and directions of evacuation leaders. According to the simulation results, only one or two leaders could get remarkable effect for a single-exit configuration. But for configurations with multi-exits, evacuation leaders would make the dynamic slower unless the guidance sufficiently utilizes every exit. The results indicate that, we should set as many leaders as the number of exits in the center of the multi-exits regular squared room, and when emergencies occur, each leader heads to a different exit. Moreover, if we do like this, the evacuation would be even faster than that with 20 random-position-leaders. This work may shed some light on the drawing up of emergency scheme for large public-gathering places like stadiums and shopping malls.

  10. Robust model-based optimization of evacuation guidance

    NARCIS (Netherlands)

    Huibregtse, O.L.

    2013-01-01

    Large scale disasters, such as floods and fires, cause many casualties. This risk of casualties is reduced by evacuating the people from the threatened region. By guiding these people, i.e. instructing them when and where to go, the efficiency of the evacuation is increased. This means that, for

  11. Gastric evacuation, feeding periodicity and daily ration of Sardine ...

    African Journals Online (AJOL)

    Estimated gastric evacuation rates ranged between 0.05 and 0.29.h-1, with mean values of 0.09 and 0.27.h-1 for fish fed zooplankton and phytoplankton respectively. Despite this large range, no significant relationships were found between gastric evacuation rate and fish size, temperature, food particle size or meal size.

  12. Clarifying evacuation options through fire behavior and traffic modeling

    Science.gov (United States)

    Carol L. Rice; Ronny J. Coleman; Mike. Price

    2011-01-01

    Communities are becoming increasingly concerned with the variety of choices related to wildfire evacuation. We used ArcView with Network Analyst to evaluate the different options for evacuations during wildfire in a case study community. We tested overlaying fire growth patterns with the road network and population characteristics to determine recommendations for...

  13. Is ward evacuation for uncomplicated incomplete abortion under ...

    African Journals Online (AJOL)

    Objective. To compare evacuation under systemic analgesia (fentanyl and midazolam) in a treatment room (ward group) with evacuation under general anaesthesia in theatre. Design. A prospective randomised clinical trial. Setting. A tertiary medical centre serving a black urban population. Subjects. One hundred and ...

  14. 14 CFR 121.570 - Airplane evacuation capability.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Airplane evacuation capability. 121.570... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations § 121.570 Airplane evacuation capability. (a) No person may cause an airplane carrying passengers to be moved on the surface, take off, or...

  15. WILLEM : a Wireless InteLLigent Evacuation Method

    NARCIS (Netherlands)

    Willigen, W.H. van; Neef, R.M.; Lieburg, A. van; Schut, M.C.

    2009-01-01

    In this paper we present WILLEM, a system for dynamic evacuation routing in buildings, using a wireless sensor network. Dynamic evacuation routing is the process of dynamically determining the fastest routes to the exits. The routes may be changed in case a fire occurs somewhere. We also present an

  16. Everscape : The Making of a Disaster Evacuation Experience

    NARCIS (Netherlands)

    Doirado, E.; Van den Berg, M.; Van Lint, J.W.C.; Hoogendoorn, S.P.; Prendinger, H.

    2012-01-01

    Disaster evacuation studies are important but difficult or impossible to conduct in the real world. Evacuation simulation in a virtual world can be an important tool to obtain data on the escape and choice behavior of people. However, to obtain accurate “realistic” data, the engagement of

  17. Effect of authority figures for pedestrian evacuation at metro stations

    Science.gov (United States)

    Song, Xiao; Zhang, Zenghui; Peng, Gongzhuang; Shi, Guoqiang

    2017-01-01

    Most pedestrian evacuation literatures are about routing algorithm, human intelligence and behavior etc. Few works studied how to fully explore the function of authority/security figures, who know more of the environment by simply being there every day. To evaluate the effect of authority figure (AF) in complex buildings, this paper fully investigates the AF related factors that may influence the evacuation effect of crowd, such as the number and locations of AFs, their spread of direction, calming effect and distribution strategies etc. Social force based modeling and simulation results show that these factors of AFs play important roles in evacuation efficiency, which means fewer AFs with right guiding strategy can have good evacuation performance. For our case study, Zhichun Avenue station, the conclusion is that deployment of four AFs is a good choice to achieve relatively high evacuation performance yet save cost.

  18. Theoretical performance of a tubular integral collector storage system; Analisis teorico del comportamiento de un colector acumulador integrado tubular

    Energy Technology Data Exchange (ETDEWEB)

    Lema, Alba; Barral, Jorge; Galimberti, Pablo [Universidad Nacional de Rio Cuarto (Argentina). Facultad de Ingenieria]. E-mail: alema@ing.unrc.edu.ar; Fasulo, Amilcar [Universidad de San Luis (Argentina). Dept. de Fisica]. E-mail afasulo@unsl.edu.ar

    2000-07-01

    A simplified theoretical dynamic computational model is developed in this work to evaluate the thermal behavior of a tubular integral-collector-storage system. A generic unit is studied under the hypothesis of isothermal nodes for the tubes and the corresponding pieces of transparent cover. The physical-mathematical model takes into account the energy balances relating the water of the tubes, the cover, and the collector surroundings. The model is codified in FORTRAN to perform simulations using the climatic local data and a typical hot water demand. The model is validated by comparing simulation results with experimental data obtained from a prototype built in a educational farm of the central part of Argentina. (author)

  19. Automatic control of plants of direct steam generation with cylinder-parabolic solar collectors; Control automatico de plantas de generacion directa de vapor con colectores solares cilindro-parabolicos

    Energy Technology Data Exchange (ETDEWEB)

    Valenzuela Gutierrez, L.

    2008-07-01

    The main objective of this dissertation has been the contributions to the operation in automatic mode of a new generation of direct steam generation solar plants with parabolic-trough collectors. The dissertation starts introducing the parabolic-trough collectors solar thermal technology for the generation of process steam or steam for a Rankine cycle in the case of power generation generation, which is currently the most developed and commercialized technology. Presently, the parabolic-trough collectors technology is based on the configuration known as heat-exchanger system, based in the use of a heat transfer fluid in the solar field which is heated during the recirculation through the absorber tubes of the solar collectors, transferring later on the that thermal energy to a heat-exchanger for steam generation. Direct steam generation in the absorber tubes has always been shown as an ideal pathway to reduce generation cost by 15% and increase conversion efficiency by 20% (DISS, 1999). (Author)

  20. Evacuation of People with Visual Impairments

    DEFF Research Database (Denmark)

    Sørensen, Janne Gress

    since the model is based on data for this group. Likewise, the theoretical model is conservative estimate for the hearing impaired participants moving on horizontal planes. For all tested subpopulations the walking speed decreased with increasing person density, but the visually impaired participants...... and with a special focus on blind and visually impaired people. An experimental program is designed to obtain data on walking speeds horizontally and descending stairs, interaction between participants and their interaction with the building environment. Experiments are conducted in different buildings including...... for a safe and easy evacuation, challenge the movement for occupants having an impairment. Quantitative results on reaction times, walking speeds horizontally and descending stairs are also obtained from the experiments. It is found that N&M model correlates with results found able-bodied. This is expected...

  1. Neutron tubes

    Science.gov (United States)

    Leung, Ka-Ngo; Lou, Tak Pui; Reijonen, Jani

    2008-03-11

    A neutron tube or generator is based on a RF driven plasma ion source having a quartz or other chamber surrounded by an external RF antenna. A deuterium or mixed deuterium/tritium (or even just a tritium) plasma is generated in the chamber and D or D/T (or T) ions are extracted from the plasma. A neutron generating target is positioned so that the ion beam is incident thereon and loads the target. Incident ions cause D-D or D-T (or T-T) reactions which generate neutrons. Various embodiments differ primarily in size of the chamber and position and shape of the neutron generating target. Some neutron generators are small enough for implantation in the body. The target may be at the end of a catheter-like drift tube. The target may have a tapered or conical surface to increase target surface area.

  2. Evacuation time estimate for a total pedestrian evacuation using queuing network model and volunteered geographic information

    CERN Document Server

    Kunwar, Bharat; Johansson, Anders

    2015-01-01

    Estimating city evacuation time is a non-trivial problem due to the interaction between thousands of individual agents, giving rise to various collective phenomena, such as bottleneck formation, intermittent flow and stop-and-go waves. We present a mean field approach to draw relationships between road network spatial attributes, number of evacuees and resultant evacuation time estimate (ETE). We divide $50$ medium sized UK cities into a total of $697$ catchment areas which we define as an area where all agents share the same nearest exit node. In these catchment areas, 90% of agents are within $5.4$ km of their designated exit node. We establish a characteristic flow rate from catchment area attributes (population, distance to exit node and exit node width) and a mean flow rate in free-flow regime by simulating total evacuations using an agent based `queuing network' model. We use these variables to determine a relationship between catchment area attributes and resultant ETE. This relationship could enable e...

  3. Theoretical study on a solar collector loop during stagnation

    DEFF Research Database (Denmark)

    Chen, Ziqian; Dragsted, Janne; Furbo, Simon

    A mathematical model simulating the stagnation behavior of a pressurized solar collector loop with solar collectors with a good emptying behavior is developed. Based on the pre-pressure of the expansion vessel, the system filling pressure of the solar collector loop and the design of the solar...... collector loop, the mass of the fluid flowing into the pressurized expansion vessel and the pressures at the top part and at the bottom part of the solar collector loop during stagnation for the solar collector loop are calculated. The theoretically calculated results are compared with experimental results....... There is a good agreement between calculations and measurements. The developed simulation model is therefore suitable to determine the behavior of solar collector loops during stagnation....

  4. Simulation of a solar collector array consisting of two types of solar collectors, with and without convection barrier

    DEFF Research Database (Denmark)

    Bava, Federico; Furbo, Simon; Perers, Bengt

    2015-01-01

    barrier, can be found on the Danish market. Depending on the temperature level at which the two types of collectors operate, one can perform better than the other. This project aimed to study the behavior of a 14 solar collector row made of these two different kinds of collectors, in order to optimize...... the composition of the row. Actual solar collectors available on the Danish market (models HT-SA and HT-A 35-10 manufactured by ARCON Solar A/S) were used for this analysis. To perform the study, a simulation model in TRNSYS was developed based on the Danish solar collector field in Braedstrup. A parametric...

  5. Performance of a Solar Heating System with Photovoltaic Thermal Hybrid Collectors and Heat Pump

    DEFF Research Database (Denmark)

    Dannemand, Mark; Furbo, Simon; Perers, Bengt

    2017-01-01

    The energy consumption in buildings accounts for a large part of the World’s CO2 emissions. Much energy is used for appliances, domestic hot water preparation and space heating. In solar heating systems, heat is captured by solar collectors when the sun is shining and used for heating purposes....... In this system, it is possible to have the high performance of the liquid/water heat pump but without the need to install tubes in the ground. The performance of the system with automated energy discharge over several months is evaluated....

  6. Research on Evacuation Based on Social Force Model

    Science.gov (United States)

    Liu, W.; Deng, Z.; Li, W.; Lin, J.

    2017-09-01

    Crowded centers always cause personnel casualties in evacuation operations. Stampede events often occur by hit, squeeze and crush due to panic. It is of vital important to alleviate such situation. With the deepening of personnel evacuation research, more and more researchers are committed to study individual behaviors and self-organization phenomenon in evacuation process. The study mainly includes: 1, enrich the social force model from different facets such as visual, psychological, external force to descript more realistic evacuation; 2, research on causes and effects of self - organization phenomenon. In this paper, we focus on disorder motion that occurs in the crowded indoor publics, especially the narrow channel and safety exits and other special arteries. We put forward the improved social force model to depict pedestrians' behaviors, an orderly speed-stratification evacuation method to solve disorder problem, and shape-changed export to alleviate congestion. The result of this work shows an improvement of evacuation efficiency by 19.5 %. Guiding pedestrians' direction to slow down the influence of social forces has a guidance function in improving the efficiency of indoor emergency evacuation.

  7. Agent-based simulation of alternative classroom evacuation scenarios

    Directory of Open Access Journals (Sweden)

    Runjiao Liu

    2016-03-01

    Full Text Available Due to the growing number of emergency accidents occurring around students, evacuation issues have become significantly important for both school officials and architects. Simply following construction codes cannot ensure that a building׳s layout is suitable for evacuation behaviors; therefore, to discover the suitable planning schemes, we have introduced an agent-based simulation model via Netlogo to investigate the interrelationships between evacuation efficiency and classroom layouts. Before conducting modeling experiments, both the simulation structure and the sensitivity to its parameter settings are examined by validation research and sensitivity analysis. Furthermore, to demonstrate the importance of conducting fire drills with students, two different types of behavior rules are designed to reflect the distinctive characteristics of students evacuating without instructions and students evacuating in good order. The general comparison results show us that the classroom layout with two exits shortens students׳ evacuation time, and the premeditated behavior rules, meaning that students who follow preset instructions to arrange their activities, not only escape faster but also have some advantages in ensuring their safety during the evacuation process. Moreover, at the end of this paper, several methods of improving this simulation model are proposed for more complex research in the future.

  8. An analysis of evacuation options for nuclear accidents

    Energy Technology Data Exchange (ETDEWEB)

    Tawil, J.J.; Strenge, D.L.; Schultz, R.W. [Battelle Memorial Inst., Richland, WA (United States)

    1987-11-01

    In this report we consider the threat posed by the accidental release of radionuclides from a nuclear power plant. The objective is to establish relationships between radiation dose and the cost of evacuation under a wide variety of conditions. The dose can almost always be reduced by evacuating the population from a larger area. However, extending the evacuation zone outward will cause evacuation costs to increase. The purpose of this analysis was to provide the Environmental Protection Agency (EPA) a data base for evaluating whether implementation costs and risks averted could be used to justify evacuation at lower doses. The procedures used and results of these analyses are being made available as background information for use by others. We develop cost/dose relationships for 54 scenarios that are based upon the severity of the reactor accident, meteorological conditions during the release of radionuclides into the environment, and the angular width of the evacuation zone. The 54 scenarios are derived from combinations of three accident severity levels, six meteorological conditions and evacuation zone widths of 70{degree}, 90{degree}, and 180{degree}.

  9. Self-tracking mechanisms for solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, K.

    1985-02-12

    A self-tracking mechanism for a solar collector comprises a plurality of sensor concentrators arranged side by side and a plurality of shape memory alloy coils each located at a position coincident with the focal line of the corresponding one of sensor concentrators. The shape memory alloy coil is treated so as to shrink into a memorized shape when heated. Each of a plurality of tension wires have one end connected to one end of the shape memory alloy coil and the other end wound up on a wire drum which is mounted on a drive shaft. A transfer mechanism is operatively connected to the drive shaft for transferring the rotation of the drive shaft to a rotatable main collector.

  10. A Self-Biasing Pulsed Depressed Collector

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, Mark A.; Jensen, Aaron; Neilson, Jeff; /SLAC

    2014-05-29

    Depressed collectors have been utilized successfully for many years to improve the electrical efficiency of vacuum electron devices. Increasingly, pulsed, high-peak power accelerator applications are placing a premium on electrical efficiency. As RF systems are responsible for a large percentage of the overall energy usage at accelerator laboratories, methods to improve upon the state-of-the-art in pulsed high-power sources are desired. This paper presents a technique for self-biasing the stages in a multistage depressed collector. With this technique, the energy lost during the rise and fall times of the pulse can be recovered, separate power supplies are not needed, and existing modulators can be retrofitted. Calculations show that significant cost savings can be realized with the implementation of this device in high-power systems. In this paper, the technique is described along with experimental demonstration. (auth)

  11. Resident perception of volcanic hazards and evacuation procedures

    Science.gov (United States)

    Bird, D. K.; Gisladottir, G.; Dominey-Howes, D.

    2009-02-01

    Katla volcano, located beneath the Mýrdalsjökull ice cap in southern Iceland, is capable of producing catastrophic jökulhlaup. The Icelandic Civil Protection (ICP), in conjunction with scientists, local police and emergency managers, developed mitigation strategies for possible jökulhlaup produced during future Katla eruptions. These strategies were tested during a full-scale evacuation exercise in March 2006. A positive public response during a volcanic crisis not only depends upon the public's knowledge of the evacuation plan but also their knowledge and perception of the possible hazards. To improve the effectiveness of residents' compliance with warning and evacuation messages it is important that emergency management officials understand how the public interpret their situation in relation to volcanic hazards and their potential response during a crisis and apply this information to the ongoing development of risk mitigation strategies. We adopted a mixed methods approach in order to gain a broad understanding of residents' knowledge and perception of the Katla volcano in general, jökulhlaup hazards specifically and the regional emergency evacuation plan. This entailed field observations during the major evacuation exercise, interviews with key emergency management officials and questionnaire survey interviews with local residents. Our survey shows that despite living within the hazard zone, many residents do not perceive that their homes could be affected by a jökulhlaup, and many participants who perceive that their homes are safe, stated that they would not evacuate if an evacuation warning was issued. Alarmingly, most participants did not receive an evacuation message during the exercise. However, the majority of participants who took part in the exercise were positive about its implementation. This assessment of resident knowledge and perception of volcanic hazards and the evacuation plan is the first of its kind in this region. Our data can be used

  12. Assessment of musculoskeletal load in refuse collectors

    Directory of Open Access Journals (Sweden)

    Zbigniew W. Jóźwiak

    2013-08-01

    Full Text Available Background: The aim of this work was to assess the load on the musculoskeletal system and its effects in the collectors of solid refuse. The rationale behind this study was to formulate proposals how to reduce excessive musculoskeletal load in this group of workers. Material and Methods: The study group comprised 15 refuse collectors aged 25 to 50 years. Data about the workplace characteristics and subjective complaints of workers were collected by the free interview and questionnaire. During the survey the photorecording of the workpostures, the distance and velocity by GPS recorders, measurements of forces necessary to move containers, energy expenditure (lung ventilation method, workload estimation using the Firstbeat system and REBA method and stadiometry were done. Results: The distance walked daily by the collectors operating in terms of 2 to 3 in urban areas was about 15 km, and in rural areas about 18 km. The most frequent musculoskeletal complaints concerned the feet (60% subjects, knees, wrists and shoulders (over 40% subjects. After work-shift all examined workers had vertebral column shorter by 10 to 14 mm (11.4 mm mean. Conclusions: The results of our study show that the refuse collectors are subjected to a very high physical load because of the work organization and the way it is performed. To avoid adverse health effects and overload it is necessary to undertake ergonomic interventions, involving training of workers to improve the way of their job performance, active and passive leisure, technical control of the equipment and refuse containers, as well as the renegotiation of contracts with clients, especially those concerning non-standard containers. Med Pr 2013;64(4:507–519

  13. High performance flat plate solar collector

    Science.gov (United States)

    Lansing, F. L.; Reynolds, R.

    1976-01-01

    The potential use of porous construction is presented to achieve efficient heat removal from a power producing solid and is applied to solar air heaters. Analytical solutions are given for the temperature distribution within a gas-cooled porous flat plate having its surface exposed to the sun's energy. The extracted thermal energy is calculated for two different types of plate transparency. Results show the great improvement in performance obtained with porous flat plate collectors as compared with analogous nonporous types.

  14. Protection of solar collector materials from UV

    Science.gov (United States)

    Castle, J. G., Jr.; Gause, R. L.; Whitaker, A.

    1978-01-01

    Certain plastic films, such as KAPTON, are known to be stable with excellent long-term aging characteristics under intense uv radiation. Our recent measurements of the optical transmission spectra of KAPTON films show an absorption edge in the blue and are interpreted in terms of an electronic excitation mechanism. The application of this type of film as covering for solar collectors is discussed in regard to the protection this strong uv absorption offers to the materials underneath.

  15. (AJST) EFFECT OF COLLECTOR, FROTHER AND DEPRESSANT ...

    African Journals Online (AJOL)

    The reagent dose rates were varied as follows: collector (10, 30, 50 and 80 g/t), frother (10, 20, and 30 g/t), and depressant (40, 60, and 100 g/t). The results showed that the addition of TDSC 39/R9004A frother (maximum recovery 72.49 % TCu with a concentrate grade of 29.5 % TCu at a dose rate of 30 g/t) to the scavenger ...

  16. Commentary on the appropriate radiation level for evacuations

    Energy Technology Data Exchange (ETDEWEB)

    Cuttler, J.M. [Cuttler and Associates Inc., Mississauga, Ontario (Canada)

    2012-03-15

    This commentary reviews the international radiation protection policy that resulted in the evacuation of more than 90,000 residents from areas near the Fukushima Daiichi NPS and the enormous expenditures to protect them against a hypothetical risk of cancer. The basis for the precautionary measures is shown to be invalid; the radiation level chosen for evacuation is not conservative. The actions caused unnecessary fear and suffering. An appropriate level for evacuation is recommended. Radical changes to the ICRP recommendations are long overdue. (author)

  17. Application of Catastrophe Risk Modelling to Evacuation Public Policy

    Science.gov (United States)

    Woo, G.

    2009-04-01

    The decision by civic authorities to evacuate an area threatened by a natural hazard is especially fraught when the population in harm's way is extremely large, and where there is considerable uncertainty in the spatial footprint, scale, and strike time of a hazard event. Traditionally viewed as a hazard forecasting issue, civil authorities turn to scientists for advice on a potentially imminent dangerous event. However, the level of scientific confidence varies enormously from one peril and crisis situation to another. With superior observational data, meteorological and hydrological hazards are generally better forecast than geological hazards. But even with Atlantic hurricanes, the track and intensity of a hurricane can change significantly within a few hours. This complicated and delayed the decision to call an evacuation of New Orleans when threatened by Hurricane Katrina, and would present a severe dilemma if a major hurricane were appearing to head for New York. Evacuation needs to be perceived as a risk issue, requiring the expertise of catastrophe risk modellers as well as geoscientists. Faced with evidence of a great earthquake in the Indian Ocean in December 2004, seismologists were reluctant to give a tsunami warning without more direct sea observations. Yet, from a risk perspective, the risk to coastal populations would have warranted attempts at tsunami warning, even though there was significant uncertainty in the hazard forecast, and chance of a false alarm. A systematic coherent risk-based framework for evacuation decision-making exists, which weighs the advantages of an evacuation call against the disadvantages. Implicitly and qualitatively, such a cost-benefit analysis is undertaken by civic authorities whenever an evacuation is considered. With the progress in catastrophe risk modelling, such an analysis can be made explicit and quantitative, providing a transparent audit trail for the decision process. A stochastic event set, the core of a

  18. Thin film absorber for a solar collector

    Science.gov (United States)

    Wilhelm, William G.

    1985-01-01

    This invention pertains to energy absorbers for solar collectors, and more particularly to high performance thin film absorbers. The solar collectors comprising the absorber of this invention overcome several problems seen in current systems, such as excessive hardware, high cost and unreliability. In the preferred form, the apparatus features a substantially rigid planar frame with a thin film window bonded to one planar side of the frame. An absorber in accordance with the present invention is comprised of two thin film layers that are sealed perimetrically. In a preferred embodiment, thin film layers are formed from a metal/plastic laminate. The layers define a fluid-tight planar envelope of large surface area to volume through which a heat transfer fluid flows. The absorber is bonded to the other planar side of the frame. The thin film construction of the absorber assures substantially full envelope wetting and thus good efficiency. The window and absorber films stress the frame adding to the overall strength of the collector.

  19. The Variable Scale Evacuation Model (VSEM: a new tool for simulating massive evacuation processes during volcanic crises

    Directory of Open Access Journals (Sweden)

    J. M. Marrero

    2010-04-01

    Full Text Available Volcanic eruptions are among the most awesome and powerful displays of nature's force, constituting a major natural hazard for society (a single eruption can claim thousands of lives in an instant. Consequently, assessment and management of volcanic risk have become critically important goals of modern volcanology. Over recent years, numerous tools have been developed to evaluate volcanic risk and support volcanic crisis management: probabilistic analysis of future eruptions, hazard and risk maps, event trees, etc. However, there has been little improvement in the tools that may help Civil Defense officials to prepare Emergency Plans. Here we present a new tool for simulating massive evacuation processes during volcanic crisis: the Variable Scale Evacuation Model (VSEM. The main objective of the VSEM software is to optimize the evacuation process of Emergency Plans during volcanic crisis. For this, the VSEM allows the simulation of an evacuation considering different strategies depending on diverse impact scenarios. VSEM is able to calculate the required time for the complete evacuation taking into account diverse evacuation scenarios (number and type of population, infrastructure, road network, etc. and to detect high-risk or "blackspots" of the road network. The program is versatile and can work at different scales, thus being capable of simulating the evacuation of small villages as well as huge cities.

  20. Traveling wave tube and method of manufacture

    Science.gov (United States)

    Vancil, Bernard K. (Inventor)

    2004-01-01

    A traveling wave tube includes a glass or other insulating envelope having a plurality of substantially parallel glass rods supported therewithin which in turn support an electron gun, a collector and an intermediate slow wave structure. The slow wave structure itself provides electrostatic focussing of a central electron beam thereby eliminating the need for focussing magnetics and materially decreasing the cost of construction as well as enabling miniaturization. The slow wave structure advantageously includes cavities along the electron beam through which the r.f. energy is propagated, or a double, interleaved ring loop structure supported by dielectric fins within a ground plane cylinder disposed coaxially within the glass envelope.

  1. photomultiplier tube

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  2. photomultiplier tubes

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  3. Geiger-Muller tubes and their manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Gair, S.A.; Copleston, R.E.

    1991-02-06

    A Geiger-Muller tube designed for use in an environment subjected to mechanical shock and vibration has a tensioned anode wire secured between first and second mounts located at opposite ends of the tube envelope. The wire tension is adjusted, preferably with a screwable-adjustment means which is locked in the adjusted position, so that the natural frequency of vibration of the tensioned wire does not resonate with any frequency to which the tube is subjected in use. The adjustment means may be included in the mount via which the envelope is evacuated and back-filled with the ionizable gas, and a gas-tight seal can be provided around this part of the mount for example by sealing off the gas pump tube. However the adjustment means may be designed into another part of the tube, for example using telescopic parts of the envelope whose sliding junction is made gas tight with a flexible seal. Alternatively, the desired tension may be obtained by welding the wire to the first mount, passing it through the second mount, tensioning it and then crimping it to the second mount. (Author).

  4. Performance Investigation and Structure Optimization of a Flat Dual-Function Solar Collector

    Directory of Open Access Journals (Sweden)

    Jinwei Ma

    2015-01-01

    Full Text Available The performance of a dual-function solar collector (DFSC that can work as either water heater or air heater depending on seasonal requirement is investigated via both experimental and numerical approaches in this paper. The numerical results are well consistent with the experimental results. Daily efficiency of the thermosiphon system with DFSC is more than 55% in water heating mode and the instantaneous air heating efficiency of the collector reaches 60%. The effects of inner parameters on the thermal efficiency of the collector are analyzed by numerical simulations of the operation of DFSC in two working modes. It is found that the depths of the two air channels in DFSC have an optimal range suitable for both working modes. The thickness of back insulation should be no less than 0.06 m to prevent heat loss via backboard, and the diameter and number of copper tubes show notable effect on the efficiency of DFSC in water heating mode but slight effect in air heating mode.

  5. Investigations for effect of Al2O3–H2O nanofluid flow rate on the efficiency of direct absorption solar collector

    Directory of Open Access Journals (Sweden)

    Hemant Kumar Gupta

    2015-03-01

    Full Text Available The efficiency of conventional tube‐ in plate type solar collectors is limited due to higher heat losses for surface based solar energy absorption and indirect transfer of heat from hot absorber surface to working fluid having poor heat transfer properties flowing through tubes. In this paper, a prototype direct absorption solar collector having gross area 1.4 m2 working on volumetric absorption principle is developed to investigate the effect of using Al2O3–H2O nanofluid as heat transfer fluid at different flow rates. Experimentation was carried using distilled water and 0.005% volume fractions of 20 nm size Al2O3 nanoparticles at three flow rates of 1.5, 2 and 2.5 lpm. ASHRAE standard 93-86 was followed for calculation of instantaneous efficiency of solar collector. Use of nanofluid improves the optical and thermo physical properties that result into an increase in the efficiency of the collector in all cases of using nanofluids in place of water. Collector efficiency enhancement of 8.1% and 4.2% has been observed for 1.5 and 2 lpm flow rate of nanofluid respectively. Optimum flow rate of 2.5 and 2 lpm towards maximum collector efficiency have also been observed for water and nanofluid respectively.

  6. Modelling gastric evacuation in gadoids feeding on crustaceans

    DEFF Research Database (Denmark)

    Andersen, Niels Gerner; Chabot, Denis; Couturier, C. S.

    2016-01-01

    A mechanistic, prey surface-dependent model was expanded to describe the course and rate of gastric evacuation in predatory fishes feeding on crustacean prey with robust exoskeletons. This was accomplished by adding a layer of higher resistance to the digestive processes outside the inner softer...... parts of a prey cylinder abstraction and splitting up the prey evacuation into two stages: an initial stage where the exoskeleton is cracked and a second where the prey remains are digested and evacuated. The model was parameterized for crustaceans with different levels of armour fed to Atlantic cod...... and Chionoecetes opilio. In accordance with the apparent intraspecific isometric relationship between exoskeleton mass and total body mass, the model described stage duration and rate of evacuation of the crustacean prey independently of meal and prey sizes. The duration of the first stage increased (0-33 h...

  7. Teaching case studies on emergency evacuation : final report

    Science.gov (United States)

    2011-02-15

    Through the development of four Harvard Kennedy School case studies, this project explored the policy and institutional dimensions of emergency evacuation planning and implementation in two major metropolitan areas Houston and New Orleans. By pro...

  8. The effect of meal size on gastric evacuation in whiting

    DEFF Research Database (Denmark)

    Andersen, Niels Gerner

    1998-01-01

    Gastric evacuation experiments were performed on whiting Merlangius merlangus fed discrete meals of different sizes. Herring Clupea harengus, sandeel Ammodytes tobianus, common goby Pomatoschistus microps, and brown shrimp Crangon crangon were tested as prey. A simple power model to describe...

  9. Theoretical Basis for the Design of a DWPF Evacuated Canister

    Energy Technology Data Exchange (ETDEWEB)

    Routt, K.R.

    2001-09-17

    This report provides the theoretical bases for use of an evacuated canister for draining a glass melter. Design recommendations are also presented to ensure satisfactory performance in future tests of the concept.

  10. SAFETY EVACUATION FROM UNDERGROUND MALL DURING URBAN FLOODING

    Science.gov (United States)

    Inoue, Tomomi; Kawanaka, Ryuji; Ishigaki, Taisuke; Ozaki, Taira; Toda, Keiichi

    Torrential rainfalls have been observed frequently in recent years and these rainfalls caused inundations in urban and rural areas. Intensity of such rainfalls were sometimes excess over the design rainfall of drainage systems and rain was running over the road. In these floods, some portion of rainwater intruded into underground spaces and the users faced the danger of underground flooding. In this paper, underground flooding in a mega-underground mall were investigated by using 2D shallow flow model with structural mesh and evacuation from there was also studied with the criteria of safety evacuation obtained by evacuation tests. The results show that flooding processes and safety of evacuation are quite different in the two cases with and without the consideration of drainage system. It means that the inflow conditions into underground space are depend on calculation results of rainwater flooding.

  11. Vacuum evacuated thermal storage in Sengenthal

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, B.; Hofbeck, K. [Georg-Simon-Ohm Hochschule Nuernberg (Germany). Fakultaet Allgemeinwissenschaften; Faulstich, M. [Technische Univ. Muenchen (Germany). Lehrstuhl fuer Rohstoff- und Energietechnologie

    2010-07-01

    This paper describes a vacuum insulated and stratified thermal hot water storage which will be built in Sengenthal in March 2011. The thermal storage is loaded with different types of renewable energy sources, especially firewood and solar thermal energy. With the high efficient tank it is possible to reduce the carbon dioxide emission by 90% and reduce the thermal losses of the storage by 80%. Within the project in Sengenthal the vacuum evacuated storage saves expectedly about 7.500 Euro fuel costs each year without regarding the advance in prices. This fact is caused by the substitution of a gas boiler by using the described tank as a buffer tank within a local heating plant which is covered by a firewood boiler. The concrete problem of the local heating plant was the fact that the power of the firewood boiler is too low to cover the demand of a new building. Without the described thermal storage with vacuum insulation there would be a need of an additional gas boiler. (orig.)

  12. Analysis and validation of a quasi-dynamic model for a solar collector field with flat plate collectors and parabolic trough collectors in series for district heating

    DEFF Research Database (Denmark)

    Tian, Zhiyong; Perers, Bengt; Furbo, Simon

    2018-01-01

    performance of the hybrid solar district heating plants is also presented. The measured and simulated results show that the integration of parabolic trough collectors in solar district heating plants can guarantee that the system produces hot water with relatively constant outlet temperature. The daily energy......A quasi-dynamic TRNSYS simulation model for a solar collector field with flat plate collectors and parabolic trough collectors in series was described and validated. A simplified method was implemented in TRNSYS in order to carry out long-term energy production analyses of the whole solar heating...... plant. The advantages of the model include faster computation with fewer resources, flexibility of different collector types in solar heating plant configuration and satisfactory accuracy in both dynamic and long-term analyses. In situ measurements were taken from a pilot solar heating plant with 5960 m...

  13. 3D Building Evacuation Route Modelling and Visualization

    Science.gov (United States)

    Chan, W.; Armenakis, C.

    2014-11-01

    The most common building evacuation approach currently applied is to have evacuation routes planned prior to these emergency events. These routes are usually the shortest and most practical path from each building room to the closest exit. The problem with this approach is that it is not adaptive. It is not responsively configurable relative to the type, intensity, or location of the emergency risk. Moreover, it does not provide any information to the affected persons or to the emergency responders while not allowing for the review of simulated hazard scenarios and alternative evacuation routes. In this paper we address two main tasks. The first is the modelling of the spatial risk caused by a hazardous event leading to choosing the optimal evacuation route for a set of options. The second is to generate a 3D visual representation of the model output. A multicriteria decision making (MCDM) approach is used to model the risk aiming at finding the optimal evacuation route. This is achieved by using the analytical hierarchy process (AHP) on the criteria describing the different alternative evacuation routes. The best route is then chosen to be the alternative with the least cost. The 3D visual representation of the model displays the building, the surrounding environment, the evacuee's location, the hazard location, the risk areas and the optimal evacuation pathway to the target safety location. The work has been performed using ESRI's ArcGIS. Using the developed models, the user can input the location of the hazard and the location of the evacuee. The system then determines the optimum evacuation route and displays it in 3D.

  14. Roof mounted solar collectors with reflectors. Evaluation; Takmonterade solfaangare med reflektorer i Markbacken. Utvaerdering

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Leif [Chalmers Tekniska Hoegskola, Goeteborg (Sweden). Maetcentralen; Perers, B. [Vattenfall Utveckling AB, Stockholm (Sweden)

    1999-09-01

    A solar heating plant designed for preheating of domestic hot water was built during the spring of 1998 at Markbacken, Oerebro. The collector panels were built with a very low profile, less than 1 m high, but they were quite wide in the east-west direction (6.6 m). The roof-placed collectors, 210 m{sup 2} in all, were thus very discreet and can not be seen from the main facades of the three-storey building on which they are placed. Also, the slim design meant that the entire collector box could be manufactured in a one-step process, bottom and sides being pressed from a single sheet of aluminium. Each collector and its reflector, also of aluminium, shared the same frame. The frame was attached to heavy bars of concrete which was placed on the flat roof. No further anchoring was needed. The tubing from the collectors was drawn to the cellar of the building through an obsolete refuse chute. The circulation pumps, heat exchangers and accumulator were placed in a cellar room. The accumulator consists of three cylindrical tanks with a maximum allowed pressure of 3 bar and a volume of 11 m{sup 3}. Heat from the accumulator is heat-exchanged to the cold water supplied to the system for producing domestic hot water. If the resulting temperature is less required extra heat is added from the district heating net. The solar heating plant has operated very well and has even produced more energy than was calculated in the pre-study. At a system temperature of 40 deg C the specific energy production is about 600 kWh/m{sup 2},year. The typical production is 126 MWh per annum, corresponding to 35% of the hot water consumption. The final cost of the system was some 20% higher than calculated. Some unforeseen additional costs resulted from the need for cellar floor reinforcement and also some roof improvement measures. Too high flow through the solar collectors and through the loading circuit for the accumulator has a destructive action on the temperature stratification in the heat

  15. Hail resistance of solar collectors with tempered glass covers

    Science.gov (United States)

    Lof, G. O. G.; French, R. R.

    1980-01-01

    The resistance of solar collectors glazed with 3 mm of tempered glass to hailstones of up to 10 cm in diameter and 0.5 kg in weight which fell on Fort Collins, Colorado is discussed. Of the ten solar heating systems directly in the hailpath with tempered glass covers, seven were undamaged, two lost one collector panel each, and a 700-panel collector had seven broken covers, amounting to a total breakage of nine panels out of 956, approximately 1%. In addition, one system with nontempered glass covers suffered two glass punctures in a 26-panel collector. It is concluded that the risk of hail damage to commercial solar collectors glazed with 3-mm tempered glass is negligibly small, and greatly exceeded by the risk of hail damage to the roofs of buildings and automobiles or to fiberglass-reinforced polyester sheets used as collector glazings.

  16. Characterization of optical collectors for concentration photovoltaic applications

    Energy Technology Data Exchange (ETDEWEB)

    Anton, I.; Pachon, D.; Sala, G. [Ciudad Universitaria s/n, Inst. de Energia Solar, Madrid (Spain)

    2003-07-01

    The design and characterization of the collector of a photovoltaic concentrator system is commonly carried out for a given receiver, the optical parameters of the collector being linked to it. This paper, which has substantial tutorial content, deals with the characterization of collectors for concentrator photovoltaic systems, independently of any receiver, and providing the necessary parameters for the design of a system. This strategy allows the parameters related to the collector and the receiver, which are usually manufactured by different industries, to be totally separated. It also allows the optical collectors coming from non-photovoltaic industries to be evaluated. The information that the mirror and lens manufacturers should provide for a photovoltaic concentrator application can be summarized under three characteristics: overall optical efficiency; light distribution; and acceptance angle. Theory, equipment, and procedures to carry out the optical characterization of the collectors are explained. (Author)

  17. Evaluation of Test Method for Solar Collector Efficiency

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    on these efficiencies, an efficiency equation is determined by regression analysis. In the test method, there are no requirements on the ambient air temperature and the sky temperature. The paper will present an evaluation of the test method for a 12.5 m² flat plate solar collector panel from Arcon Solvarme A....../S. The solar collector panel investigated has 16 parallel connected horizontal absorber fins. CFD (Computational Fluid Dynamics) simulations, calculations with a solar collector simulation program SOLEFF (Rasmussen and Svendsen, 1996) and thermal experiments are carried out in the investigation......The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximated...

  18. Effect of dividing daylight in symmetric prismatic daylight collector

    Science.gov (United States)

    Yeh, Shih-Chuan; Lu, Ju-Lin; Cheng, Yu-Chin

    2017-04-01

    This paper presented a symmetric prismatic daylight collector to collect daylight for the natural light illumination system. We analyzed the characteristics of the emerging light when the parallel light beam illuminate on the horizontally placed symmetric prismatic daylight collector. The ratio of the relative intensities of collected daylight that emerging from each surface of the daylight collector shown that the ratio is varied with the incident angle during a day. The simulation of the emerging light of the daylight collector shown that the ratio of emerging light is varied with the tilted angle when sunshine illuminated on a symmetric prismatic daylight collector which was not placed horizontally. The integration of normalized intensity is also varied with the tilted angle. The symmetric prismatic daylight collector with the benefits of reducing glare and dividing intensity of incident daylight, it is applicable to using in the natural light illumination system and hybrid system for improving the efficiency of utilizing of solar energy.

  19. Complex multimaterial insulating frames for windows with evacuated glazing

    Energy Technology Data Exchange (ETDEWEB)

    Yueping Fang; Eames, P.C.; Hyde, T.J. [University of Ulster, Newtonabbey (United Kingdom). Centre for Sustainable Technologies; Norton, B. [Dublin Institute of Technology, Dublin (Ireland)

    2005-09-01

    The thermal performance of a complex multimaterial frame consisting of an exoskeleton framework and cavities filled with insulant materials enclosing an evacuated glazing was simulated using a two-dimensional finite element model and the results were validated experimentally using a guarded hot box calorimeter. The analysed 0.5 m by 0.5 m evacuated glazing consisted of two low-emittance film coated glass panes supported by an array of 0.32 mm diameter pillars spaced 25 mm apart, contiguously sealed by a 10 mm wide metal edge seal. Thermal performance of windows employing evacuated glazing set in various complex multimaterial frames were analysed in detail. Very good agreement was found between simulations and experimental measurements of surface temperatures of the evacuated glazing window system. The heat loss from a window with an evacuated glazing and a complex multimaterial frame is about 80% of that for a window comprised of an evacuated glazing set in a single material solid frame. (author)

  20. Complex multimaterial insulating frames for windows with evacuated glazing

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Yueping; Eames, Philip C.; Hyde, Trevor J. [Centre for Sustainable Technologies, School of the Built Environment, University of Ulster, Newtownabbey, N. Ireland BT37 0QB (United Kingdom); Norton, Brian [Dublin Institute of Technology, Aungier Street, Dublin 2 (Ireland)

    2005-09-01

    The thermal performance of a complex multimaterial frame consisting of an exoskeleton framework and cavities filled with insulant materials enclosing an evacuated glazing was simulated using a two-dimensional finite element model and the results were validated experimentally using a guarded hot box calorimeter. The analysed 0.5m by 0.5m evacuated glazing consisted of two low-emittance film coated glass panes supported by an array of 0.32mm diameter pillars spaced 25mm apart, contiguously sealed by a 10mm wide metal edge seal. Thermal performance of windows employing evacuated glazing set in various complex multimaterial frames were analysed in detail. Very good agreement was found between simulations and experimental measurements of surface temperatures of the evacuated glazing window system. The heat loss from a window with an evacuated glazing and a complex multimaterial frame is about 80% of that for a window comprised of an evacuated glazing set in a single material solid frame. (author)

  1. Records review of musculoskeletal injuries in aeromedical evacuation personnel.

    Science.gov (United States)

    Serres, Jennifer L; Fouts, Brittany L; Dukes, Susan F; Maupin, Genny M; Wade, Molly E

    2015-04-01

    Aeromedical evacuation providers care for patients during air transport. By applying standard medical practices, oftentimes developed for ground care, these practitioners perform their mission duties under additional physical stress in this unique medical environment. Awkward postures and excessive forces are common occurrences among personnel operating in this domain. Additionally, anecdotal reports highlight the risk of developing musculoskeletal injuries for these providers. Currently, there is limited research focusing on musculoskeletal injuries in aeromedical evacuation providers. To determine the prevalence of musculoskeletal injuries and associated symptoms in aeromedical evacuation providers to understand the risk and burden of these injuries to military personnel. This study utilized a retrospective review of military medical records containing ICD-9 codes to investigate the incidence of musculoskeletal injuries within flight nurses and medical technicians compared to their non-flying counterparts from 2006 through 2011. Data were analyzed from 2013 through 2014. Although musculoskeletal injuries were identified within the test populations, results showed fewer injuries for aeromedical evacuation populations compared to non-aeromedical evacuation counterparts. One contributing factor may be a potential under-reporting of musculoskeletal injuries resulting from the fear of being placed on limited flying status. As flyers, aeromedical evacuation personnel must undergo yearly medical examinations and complete training courses that emphasize proper lifting techniques and physical requirements necessary for the safe and efficient transport of patients on various platforms. These additional requirements may create a healthy worker effect, likely contributing to lower musculoskeletal injuries. Published by Elsevier Inc.

  2. Dual effects of pedestrian density on emergency evacuation

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Yi, E-mail: yima23-c@my.cityu.edu.hk [School of Transportation and Logistics, Southwest Jiaotong University, Chengdu (China); Department of Architecture and Civil Engineering, City University of Hong Kong, Kowloon (Hong Kong); Lee, Eric Wai Ming; Yuen, Richard Kwok Kit [Department of Architecture and Civil Engineering, City University of Hong Kong, Kowloon (Hong Kong)

    2017-02-05

    This paper investigates the effect of the pedestrian density in building on the evacuation dynamic with simulation method. In the simulations, both the visibility in building and the exit limit of building are taken into account. The simulation results show that the effect of the pedestrian density in building on the evacuation dynamics is dual. On the one hand, when the visibility in building is very large, the increased pedestrian density plays a negative effect. On the other hand, when the visibility in building is very small, the increased pedestrian density can play a positive effect. The simulation results also show that when both the exit width and visibility are very small, the varying of evacuation time with regard to the pedestrian density is non-monotonous and presents a U-shaped tendency. That is, in this case, too large or too small pedestrian density in building is disadvantageous to the evacuation process. Our findings provide a new insight about the effect of the pedestrian density in building on the evacuation dynamic. - Highlights: • Pedestrian density inside buildings has dual effects on evacuation. • Increased pedestrian density has a negative effect in cases of increased visibility. • Increased pedestrian density has a positive effect in cases of decreased visibility.

  3. Mathematical Modeling of Dual Intake Transparent Transpired Solar Collector

    OpenAIRE

    Thomas Semenou; Rousse, Daniel R.; Brice Le Lostec; Hervé F. Nouanegue; Pierre-Luc Paradis

    2015-01-01

    Nowadays, in several types of commercial or institutional buildings, a significant rise of transpired solar collectors used to preheat the fresh air of the building can be observed. Nevertheless, when the air mass flow rate is low, the collector efficiency collapses and a large amount of energy remains unused. This paper presents a simple yet effective mathematical model of a transparent transpired solar collector (TTC) with dual intake in order to remove stagnation problems in the plenum and...

  4. The flooding of carbon collectors in Tatar fields

    Energy Technology Data Exchange (ETDEWEB)

    Kolevatova, A.N.; Solov' eva, V.N.; Suleymanov, E.I.

    1980-01-01

    The results of the development and flooding of oil deposits in carbon collectors are analyzed in this article. A short history of the field development is provided covering the period prior to, and since the flooding. It appears that the effectiveness of flooding carbon collectors in small fields in Tatariya was noted in only the Upin-Malevskiy deposits lining a relatively uniform and highly permeable collector.

  5. Experimental and simulation studies of parabolic trough collector design for obtaining solar energy

    Directory of Open Access Journals (Sweden)

    Syed Ameen Murtuza

    2017-12-01

    Full Text Available Concentrated solar power has great potential for large scale renewable energy sources, and is currently an eye catching one for its utilization with wide area of improvement. Especially, parabolic trough solar collectors (PTSCs are gaining popularity due to their increased efficiency as compared to photovoltaics. In this work, an effort has been made to evaluate the performance of a designed 5-m length PTSC model. Heat collecting element was made of stainless steel with water as working fluid. The authentication of the proposed model is justified based on the results obtained on a yearly scale with respect to average inlet and outlet temperatures, surface temperatures and thermal efficiency for the climatic conditions of Ramanagaram. It was observed that March to May yielded better outlet temperatures ranging from 93 °C to 103 °C. Experiments were carried out at different flow rates of 0.4 LPM, 0.8 LPM and 1.2 LPM and corresponding Reynolds number was calculated. It was seen that February to May gave good surface and outlet temperatures as compared with other months while the liquid flow is laminar. Simulation studies were carried out using ANSYS software on receiver tube to ensure the robustness and design effectiveness under static loading conditions. Keywords: Parabolic trough solar collector, Receiver tube, Solar thermal, Static structural analysis

  6. Simulation Application for Optimization of Solar Collector Array

    Directory of Open Access Journals (Sweden)

    Igor Shesho*,

    2014-01-01

    Full Text Available Solar systems offer a comparatively low output density , so increasing the output always means a corresponding increase in the size of the collector area. Thus collector arrays are occasionally constructed (i.e. with different azimuth angles and/or slopes, which be imposed by the location and structure available to mount the collector. In this paper is developed simulation application for optimization for the solar collector array position and number of collectors in regard of maximum annual energy gain and thermal efficiency. It is analyzed solar collector array which has parallel and serial connected solar collectors with different tilt, orientation and thermal characteristics. Measurements are performed for determine the thermal performance of the system. Using the programming language INSEL it is developed simulation program for the analyzed system where optimization is done through parametric runs in the simulation program. Accent is given on the SE orientated collectors regarding their tilt and number, comparing two solutions-scenarios and the current system set situation of the in means of efficiency and total annual energy gain. The first scenario envisages a change of angle from 35 to 25 solar panels on the SE orientation, while the second scenario envisages retaining the existing angle of 35 and adding additional solar collector. Scenario 1 accounts for more than 13% energy gain on annual basis while Scenario 2 has 2% bigger thermal efficiency.

  7. Performances and yield assessment of glazed photovoltaic-thermal collectors

    OpenAIRE

    Dupeyrat, P.; Fortuin, S.; Kwiatkowski, G.; Baranzini, M.; Schumann, M.

    2012-01-01

    Photovoltaic-Thermal (PV-T) hybrid collectors are multi-energy components that convert solar energy into both electricity and heat. In this paper, the performances of a PV-T collector are investigated. The objective is not only the evaluation of the PV-T collector itself, but the evaluation of this component operating in a real energy system. For this purpose, experimental prototypes of PV-T collector were built, tested in an indoor sun simulator and finally installed and monitored at the EDF...

  8. EFFICIENCY AND LIFETIME OF SOLAR COLLECTORS FOR SOLAR HEATING PLANTS

    OpenAIRE

    Fan, Jianhua; Chen, Ziqian; Furbo, Simon; Perers, Bengt; Karlsson, Björn

    2009-01-01

    The 12.5 m² flat plate solar collector HT, today marketed by Arcon Solvarme A/S, has been used in solar heating plants in Scandinavia since 1983. The collector is designed to operate in a temperature interval between 40°C and 90°C. The efficiency of the collector has been strongly improved since it was introduced on the market. The paper will present the increase of the efficiency of the collector due to technical improvements since 1983. Further, measurements from the spring of 2009 of the e...

  9. High Performance Flat Plate Solar Thermal Collector Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Rockenbaugh, Caleb [National Renewable Energy Lab. (NREL), Golden, CO (United States); Dean, Jesse [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lovullo, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lisell, Lars [National Renewable Energy Lab. (NREL), Golden, CO (United States); Barker, Greg [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hanckock, Ed [National Renewable Energy Lab. (NREL), Golden, CO (United States); Norton, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-09-01

    This report was prepared for the General Services Administration by the National Renewable Energy Laboratory. The Honeycomb Solar Thermal Collector (HSTC) is a flat plate solar thermal collector that shows promising high efficiencies over a wide range of climate zones. The technical objectives of this study are to: 1) verify collector performance, 2) compare that performance to other market-available collectors, 3) verify overheat protection, and 4) analyze the economic performance of the HSTC both at the demonstration sites and across a matrix of climate zones and utility markets.

  10. Adaptive control of solar energy collector systems

    CERN Document Server

    Lemos, João M; Igreja, José M

    2014-01-01

    This book describes methods for adaptive control of distributed-collector solar fields: plants that collect solar energy and deliver it in thermal form. Controller design methods are presented that can overcome difficulties found in these type of plants:they are distributed-parameter systems, i.e., systems with dynamics that depend on space as well as time;their dynamics is nonlinear, with a bilinear structure;there is a significant level of uncertainty in plant knowledge.Adaptive methods form the focus of the text because of the degree of uncertainty in the knowledge of plant dynamics. Parts

  11. Line-focus concentrating collector program

    Science.gov (United States)

    Dugan, V. L.

    1980-01-01

    The Line-Focus Concentrating Collector Program has emphasized the development and dissemination of concentrating solar technology in which the reflected sunlight is focused onto a linear or line receiver. Although a number of different types of line-focus concentrators were developed, the parabolic trough has gained the widest acceptance and utilization within the industrial and applications sectors. The trough is best applied for application scenarios which require temperatures between 140 and 600 F. Another concept, the bowl, is investigated for applications which may require temperatures in the range between 600 and 1200 F. Current technology emphases are upon the reduction of system installation cost and the implementation of production oriented engineering.

  12. Simulation of a Solar Collector Array Consisting of two Types of Solar Collectors, with and Without Convection Barrier

    OpenAIRE

    Bava, Federico; Furbo, Simon; Perers, Bengt

    2015-01-01

    The installed area of solar collectors in solar heating fields is rapidly increasing in Denmark. In this scenario even relatively small performance improvements may lead to a large increase in the overall energy production. Both collectors with and without polymer foil, functioning as convection barrier, can be found on the Danish market. Depending on the temperature level at which the two types of collectors operate, one can perform better than the other. This project aimed to study the beha...

  13. Social influence on evacuation behavior in real and virtual environments

    Directory of Open Access Journals (Sweden)

    Max Kinateder

    2016-07-01

    Full Text Available Virtual reality (VR is a promising tool to study evacuation behavior as it allows experimentally controlled, safe simulation of otherwise dangerous situations. However, validation studies comparing evacuation behavior in real and virtual environments are still scarce. We compare the decision to evacuate in response to a fire alarm in matched physical and virtual environments. 150 participants were tested individually in a one-trial experiment in one of three conditions. In the Control condition, the fire alarm sounded while the participant performed a bogus perceptual matching task. In the Passive bystander condition, the participant performed the task together with a confederate who ignored the fire alarm. In the Active bystander condition, the confederate left the room when the fire alarm went off. Half of the participants in each condition experienced the scenario in the real laboratory, and the other half in a matched virtual environment with a virtual bystander, presented in a head-mounted display. The active bystander group was more likely to evacuate, and the passive bystander group less likely to evacuate, than the control group. This pattern of social influence was observed in both the real and virtual environments, although the overall response to the virtual alarm was reduced; positive influence was comparable, whereas negative influence was weaker in VR. We found no reliable gender effects for the participant or the bystander. These findings extend the bystander effect to the decision to evacuate, revealing a positive as well as the previous negative social influence. The results support the ecological validity of VR as a research tool to study evacuation behavior in emergency situations, with the caveat that effect sizes may be smaller in VR.

  14. Neural Tube Defects

    Science.gov (United States)

    ... vitamin, before and during pregnancy prevents most neural tube defects. Neural tube defects are usually diagnosed before the infant is ... or imaging tests. There is no cure for neural tube defects. The nerve damage and loss of function ...

  15. Multiobjective Optimization of Evacuation Routes in Stadium Using Superposed Potential Field Network Based ACO

    Directory of Open Access Journals (Sweden)

    Jialiang Kou

    2013-01-01

    Full Text Available Multiobjective evacuation routes optimization problem is defined to find out optimal evacuation routes for a group of evacuees under multiple evacuation objectives. For improving the evacuation efficiency, we abstracted the evacuation zone as a superposed potential field network (SPFN, and we presented SPFN-based ACO algorithm (SPFN-ACO to solve this problem based on the proposed model. In Wuhan Sports Center case, we compared SPFN-ACO algorithm with HMERP-ACO algorithm and traditional ACO algorithm under three evacuation objectives, namely, total evacuation time, total evacuation route length, and cumulative congestion degree. The experimental results show that SPFN-ACO algorithm has a better performance while comparing with HMERP-ACO algorithm and traditional ACO algorithm for solving multi-objective evacuation routes optimization problem.

  16. Facilitating emergency hospital evacuation through uniform discharge criteria.

    Science.gov (United States)

    Sandra, Keret; Meital, Nahari; Ofer, Merin; Limor, Aharonson-Daniel; Sara, Goldberg; Bruria, Adini

    2017-05-01

    Though hospitals' operational continuity is crucial, full institutional evacuation may at times be unavoidable. The study's objective was to establish criteria for discharge of patients during complete emergency evacuation and compare scope of patients suitable for discharge pre/post implementation of criteria. Standards for patient discharge during an evacuation were developed based on literature and disaster managers. The standards were reviewed in a two-round Delphi process. All hospitals in Israel were requested to identify inpatients' that could be released home during institutional evacuation. Potential discharges were compared in 2013-2014, before and after formulation of discharge criteria. Consensus exceeding 80% was obtained for four out of five criteria after two Delphi cycles. Average projected discharge rate before and after formulation of criteria was 34.2% and 42.9%, respectively (p<0.001). Variance in potential dischargeable patients was 31-fold less in 2014 than in 2013 (MST=8,452 versus MST=264,366, respectively; p<0.001). Differences were found between small, medium and large hospitals in mean rate of dischargeable patients: 52.1%, 41.5% and 42.2%, respectively (p=0.001). The study's findings enable to forecast the extent of patients that may be released home during full emergency evacuation of a hospital; thereby facilitating preparedness of contingency plans. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. A Simple Evacuation Modeling and Simulation Tool for First Responders

    Energy Technology Data Exchange (ETDEWEB)

    Koch, Daniel B [ORNL; Payne, Patricia W [ORNL

    2015-01-01

    Although modeling and simulation of mass evacuations during a natural or man-made disaster is an on-going and vigorous area of study, tool adoption by front-line first responders is uneven. Some of the factors that account for this situation include cost and complexity of the software. For several years, Oak Ridge National Laboratory has been actively developing the free Incident Management Preparedness and Coordination Toolkit (IMPACT) to address these issues. One of the components of IMPACT is a multi-agent simulation module for area-based and path-based evacuations. The user interface is designed so that anyone familiar with typical computer drawing tools can quickly author a geospatially-correct evacuation visualization suitable for table-top exercises. Since IMPACT is designed for use in the field where network communications may not be available, quick on-site evacuation alternatives can be evaluated to keep pace with a fluid threat situation. Realism is enhanced by incorporating collision avoidance into the simulation. Statistics are gathered as the simulation unfolds, including most importantly time-to-evacuate, to help first responders choose the best course of action.

  18. Modeling and simulating for congestion pedestrian evacuation with panic

    Science.gov (United States)

    Wang, Jinhuan; Zhang, Lei; Shi, Qiongyu; Yang, Peng; Hu, Xiaoming

    2015-06-01

    A new multi-agent based congestion evacuation model incorporating panic behavior is proposed in this paper for simulating pedestrian evacuation in public places such as a stadium. Different from the existing results, pedestrians in this model are divided into four classes and each pedestrian's status can be either normal, being overtaken, or casualty. The direction of action for each individual is affected by competitive ability, distance to the exits as well as number and density of occupants within the view field of the agent. Our simulations exhibit that during the evacuation process: (1) The agents gather in front of the exits spontaneously and present arched shapes close to the exits. (2) Under the panic state the agents cohere closely and almost do not change the target exit. So other alternative exits are ignored. (3) For the case without obstacle, the casualties under panic increase greatly. But if there are obstacles (chairs), the congestion can be alleviated. Thus the casualties are reduced. (4) If certain exit is partly clogged, the evacuation becomes more efficient when adding a virtual leader. The overall simulation results show that the proposed model can reproduce the real evacuation process in a stadium quite well.

  19. Experimental studies on small intestinal pouch motility and evacuation.

    Science.gov (United States)

    Willis, S; Riesener, K P; Anurow, M; Titkova, S; Ottinger, A; Arlt, G; Schumpelick, V

    1999-01-01

    The aim of the study was to investigate pouch motility and evacuation under standardised conditions with a minimum of external influence. Ileal J-pouches had been constructed 30 cm proximal to the ileocecal valve in 10 dogs (6 pelvic/4 gastric configuration). After 8 weeks the following examinations were performed: (1) measurement of pouch compliance by balloon distension, (2) measurement of pouch contractions by strain gauge transducers, (3) radiological imaging of pouch contractions and evacuation, (4) evacuation scintigraphy and (5) radiological determination of small intestinal transit time. Compliance (2.3 +/- 1.1 mmHg/ml) and small intestinal transit time (31.6 +/- 7.5 h) were significantly higher in the pouch group than in controls (0.5 +/- 0.2 mmHg/ml, 8.0 +/- 2.8 h; p evacuation (t(1/2) = 109 +/- 52 min). Strain gauge measurements revealed irregular pouch contractions without detectable propagation. Contraction amplitudes (40.4 +/- 22.9 g) and frequencies (10.4 +/- 1.0/min) were equal all over the pouch. There were no functional differences between gastric and pelvic pouch configuration. Small intestinal pouches act as reservoirs. Uncoordinated motility patterns contribute to this function. Other factors than pouch motility are responsible for evacuation.

  20. Thermal performance of a hot-air solar collector

    Science.gov (United States)

    1978-01-01

    Report contains procedures and results of thermal-performance tests on double-glazed air solar collector. Four types of tests were carried out including thermal-efficiency and stagnation tests, collector time-constant tests to assess effects of transients, and incident-angle modifier tests. Data are presented in tables and as graphs and are discussed and analyzed.

  1. Determination of the Optimum Collector Angle for Composite Solar ...

    African Journals Online (AJOL)

    A model for predicting solar radiation available at any given time in the inhabited area in Ilorin was developed. From the equation developed, the optimum tilt angle of the collector due south was carried out. The optimum angle of tilt of the collector and the orientation are dependent on the month of the year and the location ...

  2. Preliminary design package for solar collector and solar pump

    Science.gov (United States)

    1978-01-01

    A solar-operated pump using an existing solar collector, for use on solar heating and cooling and hot water systems is described. Preliminary design criteria of the collector and solar-powered pump is given including: design drawings, verification plans, and hazard analysis.

  3. Advances in design of air-heating collectors

    CSIR Research Space (South Africa)

    Johannsen, A

    1982-11-01

    Full Text Available Principles of the operation of air-heating collectors are discussed. The fundamental differences between the design principles of air-heating as opposed to water-heating collectors are highlighted. The main requirement is the transfer of heat from...

  4. Solar collector design with respect to moisture problems

    DEFF Research Database (Denmark)

    Holck, Ole; Svendsen, Svend; Brunold, Stefan

    2003-01-01

    more ventilation openings should be made and what influence the insulation material has. Guidelines for collector designers are proposed. The design guidelines provide some suggestions to be considered during the design of solar collectors.The work was carried out within the framework of the working...

  5. ANALYSIS AND MODELING OF SOLAR EVAPORATOR-COLLECTOR

    Directory of Open Access Journals (Sweden)

    Zakaria Mohd. Amin

    2015-11-01

    Full Text Available Solar energy is considered a sustainable resource that poses little to no harmful effects on the environment. The performance of a solar system depends to a great extent on the collector used for the conversion of solar radiant energy to thermal energy. A solar evaporator-collector (SEC is basically an unglazed flat plate collector where refrigerants, such as R134a is used as the working fluid. As the operating temperature of the SEC is very low, it utilizes both solar irradiation and ambient energy leading to a much higher efficiency than the conventional collectors. This capability of SECs to utilize ambient energy also enables the system to operate at night. This type of collector can be locally made and is relatively much cheaper than the conventional collector.   At the National University of Singapore, the evaporator-collector was integrated to a heat pump and the performance was investigated for several thermal applications: (i water heating, (ii drying and (iii desalination. A 2-dimensional transient mathematical model of this system was developed and validated by experimental data. The present study provides a comprehensive study of performance. KEYWORDS: heat pump; evaporator-collector.

  6. Weathering of a flat-plate solar collector

    Science.gov (United States)

    1980-01-01

    Report contains performance evaluation of flat-plate liquid solar collector after 14-months of natural weathering. Collector efficiency was calculated and plotted as function of inlet liquid temperature. Measurements were made of ambient temperature, inlet and outlet temperatures, differential temperature and pressure, liquid flow rate, insolation, and windspeed.

  7. A tool for standardized collector performance calculations including PVT

    DEFF Research Database (Denmark)

    Perers, Bengt; Kovacs, Peter; Olsson, Marcus

    2012-01-01

    in Europe. The collector parameters used as input in the tool are compiled from tests according to EN12975, without any intermediate conversions. The main target group for this tool is test institutes and certification bodies that are intended to use it for conversion of collector model parameters (derived...

  8. Thermal performances of vertical hybrid PV/T air collector

    Science.gov (United States)

    Tabet, I.; Touafek, K.; Bellel, N.; Khelifa, A.

    2016-11-01

    In this work, numerical analyses and the experimental validation of the thermal behavior of a vertical photovoltaic thermal air collector are investigated. The thermal model is developed using the energy balance equations of the PV/T air collector. Experimental tests are conducted to validate our mathematical model. The tests are performed in the southern Algerian region (Ghardaïa) under clear sky conditions. The prototype of the PV/T air collector is vertically erected and south oriented. The absorber upper plate temperature, glass cover temperature, air temperature in the inlet and outlet of the collector, ambient temperature, wind speed, and solar radiation are measured. The efficiency of the collector increases with increase in mass flow of air, but the increase in mass flow of air reduces the temperature of the system. The increase in efficiency of the PV/T air collector is due to the increase in the number of fins added. In the experiments, the air temperature difference between the inlet and the outlet of the PV/T air collector reaches 10 ° C on November 21, 2014, the interval time is between 10:00 and 14:00, and the temperature of the upper plate reaches 45 ° C at noon. The mathematical model describing the dynamic behavior of the typical PV/T air collector is evaluated by calculating the root mean square error and mean absolute percentage error. A good agreement between the experiment and the simulation results is obtained.

  9. Analysis of a solar collector field water flow network

    Science.gov (United States)

    Rohde, J. E.; Knoll, R. H.

    1976-01-01

    A number of methods are presented for minimizing the water flow variation in the solar collector field for the Solar Building Test Facility at the Langley Research Center. The solar collector field investigated consisted of collector panels connected in parallel between inlet and exit collector manifolds to form 12 rows. The rows were in turn connected in parallel between the main inlet and exit field manifolds to complete the field. The various solutions considered included various size manifolds, manifold area change, different locations for the inlets and exits to the manifolds, and orifices or flow control valves. Calculations showed that flow variations of less than 5 percent were obtainable both inside a row between solar collector panels and between various rows.

  10. Test results, Industrial Solar Technology parabolic trough solar collector

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, V.E. [EG and G MSI, Albuquerque, NM (United States); Evans, L.R.; Matthews, C.W. [Sandia National Labs., Albuquerque, NM (United States)

    1995-11-01

    Sandia National Laboratories and Industrial Solar Technology are cost-sharing development of advanced parabolic trough technology. As part of this effort, several configurations of an IST solar collector were tested to determine the collector efficiency and thermal losses with black chrome and black nickel receiver selective coatings, combined with aluminized film and silver film reflectors, using standard Pyrex{reg_sign} and anti-reflective coated Pyrex{reg_sign} glass receiver envelopes. The development effort has been successful, producing an advanced collector with 77% optical efficiency, using silver-film reflectors, a black nickel receiver coating, and a solgel anti-reflective glass receiver envelope. For each receiver configuration, performance equations were empirically derived relating collector efficiency and thermal losses to the operating temperature. Finally, equations were derived showing collector performance as a function of input insolation value, incident angle, and operating temperature.

  11. Optical performance of fluorescent collectors integrated with microlens arrays

    Science.gov (United States)

    Damrongsak, Pattareeya; Locharoenrat, Kitsakorn

    2017-09-01

    Fluorescent collectors have been considered for being used as a light concentrator in photovoltaic applications. It is able to replace the expensive area of solar cells in order to minimize the energy cost. In this study, fluorescent collectors integrated with microlens arrays were developed in order to improve the collection efficiency. Fluorescent collectors were prepared by casting an epoxy resin solution containing Rhodamine 6G dye in the polydimethylsiloxane master mold. Polydimethylsiloxane-based microlens arrays with actual diameters of 804.06-1008.02 µm were fabricated using a replica molding technique. The microlens arrays were then integrated with the fluorescent collectors with various dye concentrations from 2.5  ×  10-4 to 4.5  ×  10-4 Molar. Experimental results were demonstrated that the implementation of polydimethylsiloxane microlens arrays on the top of fluorescent collectors was improved for both light absorption and fluorescent intensity.

  12. A solar air collector with integrated latent heat thermal storage

    Science.gov (United States)

    Charvat, Pavel; Ostry, Milan; Mauder, Tomas; Klimes, Lubomir

    2012-04-01

    Simulations of the behaviour of a solar air collector with integrated latent heat thermal storage were performed. The model of the collector was created with the use of coupling between TRNSYS 17 and MATLAB. Latent heat storage (Phase Change Material - PCM) was integrated with the solar absorber. The model of the latent heat storage absorber was created in MATLAB and the model of the solar air collector itself was created in TRNSYS with the use of TYPE 56. The model of the latent heat storage absorber allows specification of the PCM properties as well as other parameters. The simulated air collector was the front and back pass collector with the absorber in the middle of the air cavity. Two variants were considered for comparison; the light-weight absorber made of sheet metal and the heat-storage absorber with the PCM. Simulations were performed for the climatic conditions of the Czech Republic (using TMY weather data).

  13. The effects of group and position vacancy on pedestrian evacuation flow model

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jun [School of Traffic and Transportation, Beijing Jiaotong University, Beijing 100044 (China); Faculty of Computer Science, Chengdu Normal University, Chengdu 611130 (China); You, Lei [College of Information Science and Technology, Chengdu University, Chengdu 610106 (China); Wei, Juan, E-mail: weijuan0905@126.com [Faculty of Computer Science, Chengdu Normal University, Chengdu 611130 (China); Gu, Musong [College of Information Science and Technology, Southwest Jiaotong University, Chengdu 610031 (China); Liang, Ying [Chengdu Aeronautic Vocational and Technical College, Chengdu 610100 (China)

    2014-05-01

    In order to reduce the simulation error of pedestrian evacuation model, a novel three-dimensional cellular automata model was proposed with ladder factor. The calculation formula for transition probability was given in the model based on floor field, position vacancy degree and group attraction, and the evacuation strategy was presented. Meanwhile, the experiment studied the relationships of evacuation time, mean system velocity as well as pedestrian density. The result showed that the evacuation time could be reduced effectively when the mean system velocity and position vacancy had proper degree, and the bigger group had negative effect with the evacuation time, so the bigger group should be avoided in actual evacuation process.

  14. Projection of distributed-collector solar-thermal electric power plant economics to years 1990-2000

    Science.gov (United States)

    Fujita, T.; Elgabalawi, N.; Herrera, G.; Turner, R. H.

    1977-01-01

    A preliminary comparative evaluation of distributed-collector solar thermal power plants was undertaken by projecting power plant economics of selected systems to the 1990 to 2000 time frame. The selected systems include: (1) fixed orientation collectors with concentrating reflectors and vacuum tube absorbers, (2) one axis tracking linear concentrator including parabolic trough and variable slat designs, and (3) two axis tracking parabolic dish systems including concepts with small heat engine-electric generator assemblies at each focal point as well as approaches having steam generators at the focal point with pipeline collection to a central power conversion unit. Comparisons are presented primarily in terms of energy cost and capital cost over a wide range of operating load factors. Sensitvity of energy costs for a range of efficiency and cost of major subsystems/components is presented to delineate critical technological development needs.

  15. Design and construction of a solar collector of parabolic channel; Diseno y construccion de un colector solar de canal parabolico

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar, J. O.; Calam, J. S.; Acosta, R.; Cuevas, J. D.; Hernandez, J.; Jaramillo, O. A.; Perez-Rabago, C.; Flores, J. J.

    2008-07-01

    Design and construction of 1.06 m width and 2.44 m large parabolic trough collector with 0.26 m focal length and 90 degree centigrade rim angle are presented. The design of collector components was made using CAD/CAM commercial software and they were machined with computerized numerical control (CNC). The ray tracing analysis showed that the optimal absorber diameter is 5 mm, neglecting errors or imperfections however, for mechanical and standardization reasons, it was decided to use and absorbent tube diameter of 19,05. Structural stress by finite element analysis it showed that the minimum safety factor was 4,21 and 34,22 MPa the maximum value of stress. Considering that the aluminum allowable stress is 145 MPa, then the proposed prototype resist the design loads without deformed permanently. (Author)

  16. Studies of flat-plate solar air collectors with absorber plates made of amorphous silicon photovoltaic modules; Amorphous taiyo denchi module wo shunetsuban to shita heibangata kukishiki shunetsuki no kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Sato, K.; Ito, S.; Miura, N. [Kanagawa Institute of Technology, Kanagawa (Japan)

    1996-10-27

    A light/heat hybrid air type heat collector has been developed in which heat is collected by solar cell panels. In Type 1 heat collector provided with a glass cover, two modules are connected in series and placed under a glass cover to serve as a heat collecting plate, each module built of a steel plate and two thin-film amorphous solar cells bonded to the steel plate. Air runs under the heat collecting plate. Type 2 heat collector is a Type 1 heat collector minus the glass cover. Air is taken in by a fan, runs in a vinyl chloride tube, and then through the heat collector where it is heated by the sun, and goes out at the exit. Heat collecting performance was subjected to theoretical analysis. This heat collector approximated in point of heat collection a model using a board painted black, which means that the new type functions effectively as an air-type heat collector. Operating as a photovoltaic power generator, the covered type generated approximately 20% less than the uncovered type under 800W/m{sup 2} insolation conditions. Type 1 has been in service for five months, and Type 2 for 2 months. At present, both are free of troubles such as deformation and the amorphous solar cell modules have deteriorated but a little. 4 refs., 9 figs.

  17. Mathematical Modeling of a developed Central Receiver Based on Evacuated Solar Tubes

    National Research Council Canada - National Science Library

    Ali, Basil. H; Gilani, S. I; Al-Kayiem, Hussain H

    2016-01-01

    ..., where the energy and mass conservation equations are used to determine the working fluid temperature and state through the receiver parts, beside the calculation and analysis of the thermal losses.

  18. Simulation of the shopping center 'Zona I' evacuation

    Directory of Open Access Journals (Sweden)

    Jevtić Radoje B.

    2014-01-01

    Full Text Available One of the most important and the most complex tasks in human protection and human safety in objects is the projecting of the object evacuation. There are many factors that could effect on the opportune living of object such as object assignment, arrangement of rooms, arrangement of furniture, arrangement of exits, occupant speed and many other that human lives and material properties depend on. This is very important for objects with great number of humans, such as high residential objects, shopping centers, schools, hospitals etc. This paper has written to show the possible evacuation situations and calculate minimal time for evacuation in case of the shopping center 'Zona I' in Niš.

  19. SCALING AN URBAN EMERGENCY EVACUATION FRAMEWORK: CHALLENGES AND PRACTICES

    Energy Technology Data Exchange (ETDEWEB)

    Karthik, Rajasekar [ORNL; Lu, Wei [ORNL

    2014-01-01

    Critical infrastructure disruption, caused by severe weather events, natural disasters, terrorist attacks, etc., has significant impacts on urban transportation systems. We built a computational framework to simulate urban transportation systems under critical infrastructure disruption in order to aid real-time emergency evacuation. This framework will use large scale datasets to provide a scalable tool for emergency planning and management. Our framework, World-Wide Emergency Evacuation (WWEE), integrates population distribution and urban infrastructure networks to model travel demand in emergency situations at global level. Also, a computational model of agent-based traffic simulation is used to provide an optimal evacuation plan for traffic operation purpose [1]. In addition, our framework provides a web-based high resolution visualization tool for emergency evacuation modelers and practitioners. We have successfully tested our framework with scenarios in both United States (Alexandria, VA) and Europe (Berlin, Germany) [2]. However, there are still some major drawbacks for scaling this framework to handle big data workloads in real time. On our back-end, lack of proper infrastructure limits us in ability to process large amounts of data, run the simulation efficiently and quickly, and provide fast retrieval and serving of data. On the front-end, the visualization performance of microscopic evacuation results is still not efficient enough due to high volume data communication between server and client. We are addressing these drawbacks by using cloud computing and next-generation web technologies, namely Node.js, NoSQL, WebGL, Open Layers 3 and HTML5 technologies. We will describe briefly about each one and how we are using and leveraging these technologies to provide an efficient tool for emergency management organizations. Our early experimentation demonstrates that using above technologies is a promising approach to build a scalable and high performance urban

  20. Development of a 200 W CW high efficiency traveling wave tube at 12 GHz. [for use in communication technology satellites

    Science.gov (United States)

    Christensen, J. A.; Tammaru, I.

    1974-01-01

    The design, development, and test results are reported for an experimental PPM focused, traveling-wave tube that produces 235 watts of CW RF power over 85 MHz centered at 12.080 GHz. The tube uses a coupled cavity RF circuit with a velocity taper for greater than 30 percent basic efficiency. Overall efficiency of 51 percent is achieved by means of a nine stage depressed collector designed at NASA Lewis Research Center. This collector is cooled by direct radiation to deep space.

  1. Study of Cylindrical Honeycomb Solar Collector

    Directory of Open Access Journals (Sweden)

    Atish Mozumder

    2014-01-01

    Full Text Available We present the results of our investigation on cylindrical honeycomb solar collector. The honeycomb has been fabricated with transparent cellulose triacetate polymer sheets. Insulation characteristics of the honeycomb were studied by varying the separation between the honeycomb and the absorber plate. The optimal value of the separation was found to be 3.3 mm for which the heat transfer coefficient is 3.06 W m−2 K−1. This supports result of previous similar experiments. Further we test the honeycomb through a field experiment conducted in Delhi (28.6°N, 77°E and found that when the incident angle of the solar radiation is within 20° then the performance of the system with the honeycomb is better than the one without the honeycomb.

  2. Use of membrane collectors in electrostatic precipitators.

    Science.gov (United States)

    Bayless, D J; Pasic, H; Alam, M K; Shi, L; Haynes, B; Cochran, J; Khan, W

    2001-10-01

    Membrane collection surfaces, developed and patented by researchers at Ohio University, were used to replace steel plates in a dry electrostatic precipitator (ESP). Such replacement facilitates tension-based rapping, which shears the adhered particle layer from the collector surface more effectively than hammer-based rapping. Tests were performed to measure the collection efficiency of the membranes and to quantify the potential improvements of this novel cleaning technique with respect to re-entrainment. Results indicate that even semiconductor materials (e.g., carbon fibers) collect ash nearly as efficiently as steel plates, potentially indicating that collection surface resistivity is primarily dictated by the accumulated ash layer and not by the underlying plate conductivity. In addition, virtually all sheared particles separated from the collecting membranes fell within the boundary layer of the membrane, indicating extremely low potential for re-entrainment.

  3. Alignment method for solar collector arrays

    Science.gov (United States)

    Driver, Jr., Richard B

    2012-10-23

    The present invention is directed to an improved method for establishing camera fixture location for aligning mirrors on a solar collector array (SCA) comprising multiple mirror modules. The method aligns the mirrors on a module by comparing the location of the receiver image in photographs with the predicted theoretical receiver image location. To accurately align an entire SCA, a common reference is used for all of the individual module images within the SCA. The improved method can use relative pixel location information in digital photographs along with alignment fixture inclinometer data to calculate relative locations of the fixture between modules. The absolute locations are determined by minimizing alignment asymmetry for the SCA. The method inherently aligns all of the mirrors in an SCA to the receiver, even with receiver position and module-to-module alignment errors.

  4. Genesis Solar Wind Array Collector Cataloging Status

    Science.gov (United States)

    Burkett, P.J.; Rodriguez, M.C.; Calaway, M.C.; Allton, J.H.

    2009-01-01

    Genesis solar wind array collectors were fractured upon landing hard in Utah in 2004. The fragments were retrieved from the damaged canister, imaged, repackaged and shipped to the Johnson Space Center curatorial facility [1]. As of January 2009, the collection consists of 3460 samples. Of these, 442 are comprised into "multiple" sample groupings, either affixed to adhesive paper (177) or collected in jars (17), culture trays (87), or sets of polystyrene vials (161). A focused characterization task was initiated in May 2008 to document the largest samples in the collection. The task consisted of two goals: to document sapphire based fragments greater than 2 cm in one dimension, and to document silicon based fragments greater than 1 cm in one direction.

  5. Getting out of harm's way - evacuation from tsunamis

    Science.gov (United States)

    Jones, Jeanne M.; Wood, Nathan J.; Gordon, Leslie C.

    2015-01-01

    Scientists at the U.S. Geological Survey (USGS) have developed a new mapping tool, the Pedestrian Evacuation Analyst, for use by researchers and emergency managers to estimate how long it would take for someone to travel on foot out of a tsunami-hazard zone. The ArcGIS software extension, released in September 2014, allows the user to create maps showing travel times out of hazard zones and to determine the number of people that may or may not have enough time to evacuate. The maps take into account the elevation changes and the different types of land cover that a person would encounter along the way.

  6. Modelling gastric evacuation in gadoids feeding on crustaceans

    DEFF Research Database (Denmark)

    Andersen, Niels Gerner; Chabot, Denis; Couturier, C. S.

    2016-01-01

    and Chionoecetes opilio. In accordance with the apparent intraspecific isometric relationship between exoskeleton mass and total body mass, the model described stage duration and rate of evacuation of the crustacean prey independently of meal and prey sizes. The duration of the first stage increased (0-33 h......) and the evacuation rate of both stages decreased (by a half) with increasing level of the crustacean armament in terms of chitin and ash. A common, interspecific parameterization of the model within each of the categories krill, shrimp and crab can probably be used if the contents of chitin and ash are similar among...

  7. Modified Static Floor Field and Exit Choice for Pedestrian Evacuation

    Science.gov (United States)

    Xu, Yan; Huang, Hai-Jun; Yong, Gui

    2012-08-01

    An improved floor field model is proposed to simulate the pedestrian evacuation behavior in a room with multiple exits by modifying the static floor field. The modified static floor field is determined additionally by two cognitive coefficients of exit width and congestion degree around the exits. The logit-based discrete choice principle is used to govern the initial exit selection strategy based on the modified static floor field in such a scenario that pedestrians are distributed in the room's specified zone. Simulation results show that the proposed model can better perform the evacuation process. Sensitivity analyses of the model parameters are also presented.

  8. Nasogastric feeding tube

    Science.gov (United States)

    ... of what to do. What to Expect at Home If your child has an NG tube, try to keep your child from touching or pulling on the tube. After your nurse teaches you how to flush the tube and perform skin care around the nose, set up a daily routine for these tasks. Flushing the Tube Flushing the ...

  9. PERFORMANCE EVALUATION OF SOLAR COLLECTORS USING A SOLAR SIMULATOR

    Directory of Open Access Journals (Sweden)

    M. Norhafana

    2015-11-01

    Full Text Available Solar water heating systems is one of the applications of solar energy. One of the components of a solar water heating system is a solar collector that consists of an absorber. The performance of the solar water heating system depends on the absorber in the solar collector. In countries with unsuitable weather conditions, the indoor testing of solar collectors with the use of a solar simulator is preferred. Thus, this study is conducted to use a multilayered absorber in the solar collector of a solar water heating system as well as to evaluate the performance of the solar collector in terms of useful heat of the multilayered absorber using the multidirectional ability of a solar simulator at several values of solar radiation. It is operated at three variables of solar radiation of 400 W/m2, 550 W/m2 and 700 W/m2 and using three different positions of angles at 0º, 45º and 90º. The results show that the multilayer absorber in the solar collector is only able to best adapt at 45° of solar simulator with different values of radiation intensity. At this angle the maximum values of useful heat and temperature difference are achieved. KEYWORDS: solar water heating system; solar collector; multilayered absorber; solar simulator; solar radiation 

  10. Evaluation of heat transfer enhancement in air-heating collectors

    Energy Technology Data Exchange (ETDEWEB)

    Mattox, D. L.

    1979-06-01

    The present research effort was initiated for the purpose of increasing the thermal efficiency of air heating solar collectors through identification and development of optimum design and operation criteria for solar absorber-to-air heat exchangers. Initially this effort took the form of a solar collector systems analysis to evaluate the impact of various techniques for enhancing the heat transfer between the absorber and air stream on overall thermal performance of the entire solar collector. This systems analysis resulted in the selection of solar collector designs providing ducted cooling air on the absorber shaded side as a base line. A transient heat transfer analysis of a complete solar air heating collector was used to demonstrate that an optimum absorber-to-air heat exchanger design could be provided with several interrupted fin configurations. Additional analyses were performed to establish that the maximum solar collector thermal performance to required pumping power was realized for a Reynolds number range of 1000 to 2000. This Reynolds number range was used to establish a theoretical design limit curve for maximum thermal performance versus required pumping power for all interrupted fin designs as published in the open literature. Heat and momentum transfer empirical relationships were defined for scaling the state-of-the-art high conductance fin designs identified from a compact configuration to the less compact designs needed for solar collectors.

  11. A high performance porous flat-plate solar collector

    Science.gov (United States)

    Lansing, F. L.; Clarke, V.; Reynolds, R.

    1979-01-01

    A solar collector employing a porous matrix as a solar absorber and heat exchanger is presented and its application in solar air heaters is discussed. The collector is composed of a metallic matrix with a porous surface which acts as a large set of cavity radiators; cold air flows through the matrix plate and exchanges heat with the thermally stratified layers of the matrix. A steady-state thermal analysis of the collector is used to determine collector temperature distributions for the cases of an opaque surface matrix with total absorption of solar energy at the surface, and a diathermanous matrix with successive solar energy absorption at each depth. The theoretical performance of the porous flat plate collector is shown to exceed greatly that of a solid flat plate collector using air as the working medium for any given set of operational conditions. An experimental collector constructed using commercially available, low cost steel wool as the matrix has been found to have thermal efficiencies from 73 to 86%.

  12. Numerical analysis of a coupled solar collector latent heat storage unit using various phase change materials for heating the water

    Energy Technology Data Exchange (ETDEWEB)

    El Qarnia, Hamid [Universite Cadi Ayyad, Faculte des Sciences Semlalia, Departement de Physique, Laboratoire de Mecanique des Fluides et d' energetique, B.P., 2390 Marrakech (Morocco)

    2009-02-15

    A theoretical model based on the energy equations was developed to predict the thermal behaviour and performance of a solar latent heat storage unit (LHSU) consisting of a series of identical tubes embedded in the phase change material (PCM). During charging mode, a heat transfer fluid (hot water) from the solar collector passes through the tubes and transfers the collecting heat of solar radiation to the PCM. The heat stored in the liquid PCM is next transferred to water during discharging mode to produce heating water. A simulation program based on the finite volume approach was also developed to numerically evaluate the thermal performance of the LHSU. The model was first validated by comparing the results of numerical simulations to the experimental data. A series of numerical simulations were conducted for three kinds of PCM (n-octadecane, Paraffin wax and Stearic acid) to find the optimum design for a given summer climatic conditions of Marrakech city: solar radiation and ambient temperature. Optimization of the LHSU involves determination of the mass of the PCM, the number of tubes, and the flow rate water in solar collector that maximise the thermal storage efficiency. Several simulations were also made to study the effect of the flow rate water on its outlet temperature, during the discharging mode. (author)

  13. Prey exoskeletons influence the course of gastric evacuation in Atlantic cod Gadus morhua

    DEFF Research Database (Denmark)

    Couturier, C. S.; Andersen, N. G.; Audet, C.

    2013-01-01

    This study examined the effects of prey exoskeleton characteristics on gastric evacuation patterns in Atlantic cod Gadus morhua. Three distinct stages were highlighted in the gastric evacuation of crustacean prey characterized by a robust exoskeleton. The experiments confirmed that the three shrimp...... of the prey exoskeleton all affected gastric evacuation: duration of initial delay, overall evacuation rate and a decreased evacuation rate at the end of the process. The power exponential function (PEF), with its shape parameter, described the course of evacuation for these prey types well, especially...... the initial delay. The PEF does not, however, allow describing evacuation by the current stomach content mass independent of meal size, which limits its usefulness in estimating consumption rates of wild G. morhua. To predict and describe gastric evacuation of prey with a robust exoskeleton, it is therefore...

  14. Emergency communications for evacuation (EVAC) in New Orleans impact assessment report.

    Science.gov (United States)

    2015-05-01

    This document constitutes the Impact Assessment Report for Emergency Communications for Evacuation (EVAC) in : New Orleans. Response, Emergency Staging and Communications, Uniform Management, and Evacuation : (R.E.S.C.U.M.E.) is a bundle of applicati...

  15. A review on travel behaviour modelling in dynamic traffic simulation models for evacuations

    NARCIS (Netherlands)

    Pel, A.J.; Bliemer, M.C.J.; Hoogendoorn, S.P.

    2011-01-01

    Dynamic traffic simulation models are frequently used to support decisions when planning an evacuation. This contribution reviews the different (mathematical) model formulations underlying these traffic simulation models used in evacuation studies and the behavioural assumptions that are made. The

  16. Integrating supply and demand aspects of transportation for mass evacuation under disasters.

    Science.gov (United States)

    2009-10-15

    This study seeks to address real-time operational needs in the context of the evacuation response problem by providing a capability to dynamically route vehicles under evacuation, thereby being responsive to the actual conditions unfolding in real-ti...

  17. Annual measured and simulated thermal performance analysis of a hybrid solar district heating plant with flat plate collectors and parabolic trough collectors in series

    DEFF Research Database (Denmark)

    Tian, Zhiyong; Perers, Bengt; Furbo, Simon

    2017-01-01

    the district heating network to about 70 °C and then the parabolic trough collectors would heat the preheated water to the required supply temperature of the district heating network. Annual measured and simulated thermal performances of both the parabolic trough collector field and the flat plate collector...... in large solar heating plants for a district heating network, a hybrid solar collector field with 5960 m2 flat plate collectors and 4039 m2 parabolic trough collectors in series was constructed in Taars, Denmark. The design principle is that the flat plate collectors preheat the return water from...... field are presented in this paper. The thermal performance of both collector fields with weather data of a Design Reference Year was simulated to have a whole understanding of the application of both collectors under Danish climate conditions as well. These results not only can provide a design basis...

  18. Mathematical modelling of unglazed solar collectors under extreme operating conditions

    DEFF Research Database (Denmark)

    Bunea, M.; Perers, Bengt; Eicher, S.

    2015-01-01

    average temperature levels at the evaporator. Simulation of these systems requires a collector model that can take into account operation at very low temperatures (below freezing) and under various weather conditions, particularly operation without solar irradiation.A solar collector mathematical model...... was found due to the condensation phenomenon and up to 40% due to frost under no solar irradiation. This work also points out the influence of the operating conditions on the collector's characteristics.Based on experiments carried out at a test facility, every heat flux on the absorber was separately...

  19. Fuzzy Approximate Model for Distributed Thermal Solar Collectors Control

    KAUST Repository

    Elmetennani, Shahrazed

    2014-07-01

    This paper deals with the problem of controlling concentrated solar collectors where the objective consists of making the outlet temperature of the collector tracking a desired reference. The performance of the novel approximate model based on fuzzy theory, which has been introduced by the authors in [1], is evaluated comparing to other methods in the literature. The proposed approximation is a low order state representation derived from the physical distributed model. It reproduces the temperature transfer dynamics through the collectors accurately and allows the simplification of the control design. Simulation results show interesting performance of the proposed controller.

  20. Calculating the Solar Energy of a Flat Plate Collector

    Directory of Open Access Journals (Sweden)

    Ariane Rosario

    2014-09-01

    Full Text Available The amount of solar energy that could be obtained by a flat plate solar collector of one square meter dimension is calculated in three different locations: Tampa FL, Fairbanks AL, and Pontianak Indonesia, considering the varying sunset time for each day of the year. The results show that if the collectors are placed near the equator, more total energy could be obtained. In fact, by placing a solar collector in Pontianak, Indonesia 12.42% more solar energy can be obtained than by placing it in Tampa and 96.9% more solar energy than Alaska.

  1. 14 CFR 121.291 - Demonstration of emergency evacuation procedures.

    Science.gov (United States)

    2010-01-01

    ...) Initial introduction of a type and model of airplane into passenger-carrying operation; (2) Changing the number, location, or emergency evacuation duties or procedures of flight attendants who are required by... passengers and observed by the Administrator, in which the flight attendants for that type and model of...

  2. Considering culture in evacuation planning and consequence management.

    Science.gov (United States)

    Bergeron, Wayne P

    2015-01-01

    Because culture profoundly affects human behavior, it is important that emergency management decision makers from both government and the private sector who will be involved in the management of evacuation operations build cultural considerations into their planning, preparations, education, and training from the very beginning. Preparation in this regard ensures that when the crisis hits, the response efforts undertaken will at a minimum not disregard culture or make situations worse because of a lack of cultural understanding and optimally will use the consideration of culture to frame the most effective response possible to ultimately save lives and relieve suffering. Whether it is recognizing that in some cultures the decision to comply with evacuation advice and orders will be made by a matriarch or patriarch of the family, or that the ability of an entire extended family unit to remain together in the evacuation process will be the key to compliance, culture may be the pivotal factor in a successful outcome. It is these (and many more) small cultural considerations and an overall understanding of the effect that culture has on behavior that can enhance the overall effectiveness of a culturally aware organization involved in the management of evacuation operations and emergency response. Hopefully, this initial work begins a deeper discussion and evaluation of cultural aspects both concerning the populations and cultures impacted by events, but just as importantly, the cultures and cultural understanding of the responding organizations.

  3. is misoprostol a suitable alternative to the surgical evacuation

    African Journals Online (AJOL)

    2013-06-11

    Jun 11, 2013 ... Request for reprint to: Dr. B. Chigbu, Department of Obstetrics and Gynaecology, Abia State University Teaching. Hospital, PMB 7004, Abia State, Nigeria. IS MISOPROSTOL A SUITABLE ALTERNATIVE TO THE SURGICAL. EVACUATION OF INCOMPLETE ABORTION IN RURAL SOUTH-EASTERN.

  4. Integrating Decentralized Indoor Evacuation with Information Depositories in the Field

    Directory of Open Access Journals (Sweden)

    Haifeng Zhao

    2017-07-01

    Full Text Available The lonelier evacuees find themselves, the riskier become their wayfinding decisions. This research supports single evacuees in a dynamically changing environment with risk-aware guidance. It deploys the concept of decentralized evacuation, where evacuees are guided by smartphones acquiring environmental knowledge and risk information via exploration and knowledge sharing by peer-to-peer communication. Peer-to-peer communication, however, relies on the chance that people come into communication range with each other. This chance can be low. To bridge between people being not at the same time at the same places, this paper suggests information depositories at strategic locations to improve information sharing. Information depositories collect the knowledge acquired by the smartphones of evacuees passing by, maintain this information, and convey it to other passing-by evacuees. Multi-agent simulation implementing these depositories in an indoor environment shows that integrating depositories improves evacuation performance: It enhances the risk awareness and consequently increases the chance that people survive and reduces their evacuation time. For evacuating dynamic events, deploying depositories at staircases has been shown more effective than deploying them in corridors.

  5. Development of Cladding Materials for Evacuated Panel Superinsulation

    Energy Technology Data Exchange (ETDEWEB)

    Wilkes, K.E.; Weaver, F.J.; Cumberbatch, G.M.; Begnoche, B.; Brodie, V.; Lamb, W.; Reitz, R.; Caldwell, P.; Meyer, C.

    1999-11-01

    This Cooperative Research and Development Agreement (CRADA) was among E.I. DuPont de Nemours and Company, VacuPanel, Inc., and Lockheed Martin Energy Research Corp. Evacuated panel superinsulations have thermal resistivities (R) substantially above that of conventional existing insulation without the environmental problems of some insulations such as foam insulations blown with Chlorofluorocarbons (CFCs) or hydrochlorofluorocarbons (HCFCs).

  6. Neighborhood organization activities: evacuation drills, clusters, and fire safety awareness

    Science.gov (United States)

    Dick White

    1995-01-01

    Emergency preparedness activities of one Berkeley-Oakland Hills neighborhood at the wildland/urban interface include establishing clusters that reduce fire hazards and fuel loads, setting aside emergency supplies, and identifying evacuation routes; taking emergency preparedness courses from the Offices of Emergency Services of Berkeley and Oakland (the CERT and CORE...

  7. Evacuation of mixed populations from trains on bridges

    DEFF Research Database (Denmark)

    Kindler, C.; Sørensen, J.G.; Dederichs, A.S.

    2012-01-01

    An understanding of human evacuation dynamics and performance are important when designing complex buildings such as bridges and when applying performance-based codes in order to reduce the risk of exposing occupants to critical conditions in case of fire. The majority of previous studies deal...

  8. 14 CFR Appendix J to Part 25 - Emergency Evacuation

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Emergency Evacuation J Appendix J to Part 25 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... an emergency exit. (j) Seat belts and shoulder harnesses (as required) must be fastened. (k) Before...

  9. Effects of a Sprinkler on Evacuation Dynamics in Fire

    Directory of Open Access Journals (Sweden)

    Kazuhiro Yamamoto

    2015-06-01

    Full Text Available A fire in an enclosed space, such as a room in a building, is generally called a compartment fire. To prevent the compartment fire, a sprinkler for first-aid fire-fighting is installed in rooms. However, it is difficult to determine the degree to which smoke generation and the fire spreading will be inhibited when sprinklers are on. In particular, demonstrating evacuation behavior assuming an actual fire is impossible. In this study, we evaluated an effectiveness of the sprinkler by numerical simulations. To consider evacuation dynamics, a real-coded cellular automata (RCA was used, where we can freely set the direction and velocity of an evacuee based on a floor field model. To consider the situation in the room fire, we used a simulator called Fire Dynamics Simulator (FDS. Two cases with and without the sprinkler were compared to see the validity of the sprinkler on evacuation dynamics. The effect of smoke and the expansion of the fire-spreading region were discussed. Results show that, since the fire-spreading region disappears when the sprinkler is actuated, the evacuation time decreases. Even though the sprinkler is actuated, the smoke generated at the beginning of a fire diffuses inside the whole room. However, the duration of evacuees being overwhelmed by smoke is less, because the amount of smoke generated by the pyrolysis reaction is much decreased.

  10. A Space-Time Flow Optimization Model for Neighborhood Evacuation

    Science.gov (United States)

    2010-03-01

    Arriba KEN04 750 2.1 2 17. Montrose and Cheltenham MONTROSE01 1000 2.8 3 18. Williams and Palomino PALOMINO16 850 2.4 3 19. Montrose and Tunnel TUNNEL24...homes. Losing the intersection of Palomino and Williams isolates 51 homes, but results in an improvement in evacuation time for the remaining homes

  11. Escape, evacuation, and rescue research project : phase 2

    Energy Technology Data Exchange (ETDEWEB)

    Bercha, F.G. [Bercha Engineering Ltd., Calgary, AB (Canada)

    2003-04-01

    This report describes the work from the Escape, Evacuation and Rescue (EER) research project conducted between April 2001 and March 2003. The objectives were to develop EER performance-based standards (PBS) for offshore oil and gas installations in Canadian waters. It included studies of human performance under extreme conditions, reliability analysis of a specific evacuation system, and the incorporation of research findings into a computer simulation program called the Risk and Performance Tool (RPT). The newest version of the RPT was applied to make use of three major improvements and modifications. This report also discussed the application of RPT to generate information in support of the PBS development program. Methods of quantifying psychological and physiological stressors into the RPT were developed. The RPT was applied to the reliability analysis of the preferred orientation and displacement system. The results indicate the contributions of human and mechanical factors in evacuation performance. Results showed that for evacuations in calm conditions, human error and mechanical failure made the same contribution. Under moderate and severe conditions, human error contributed about twice as much to failure as mechanical failure. Under extreme conditions, both human error and mechanical failure were at the limit. A series of recommendations were proposed to improve performance-based standards. refs., tabs., figs.

  12. Nonlinear Effects in Examples of Crowd Evacuation Scenarios

    DEFF Research Database (Denmark)

    Starke, Jens; Berg Thomsen, Kristian; Sørensen, Asger

    2014-01-01

    Severe accidents with many fatalities have occurred when too many pedestrians had to maneuver in too tight surroundings, as during evacuations of mass events. This demonstrates the importance of a better general understanding of pedestrians and emergent complex behavior in crowds. To this end, we...

  13. Regional Evacuation Modeling: A State of the Art Reviewing

    Energy Technology Data Exchange (ETDEWEB)

    Southworth, F.

    1991-01-01

    Regional evacuation modeling is treated as a five step process: involving vehicle trip generation, trip departure time, trip destination, and trip route selection modeling, supplemented by plan set-up and analysis procedures. Progress under each of these headings is reviewed and gaps in the process identified. The potential for emergency planners to make use of real time traffic data, resulting from the recent technical and economic revolutions in telecommunications and infrared traffic sensing, is identified as the single greatest opportunity for the near future; and some beginnings in the development of real time dynamic traffic modeling specifically geared to evacuation planning are highlighted. Significant data problems associated with the time of day location of large urban populations represent a second area requiring extensive research. A third area requiring much additional effort is the translation of the considerable knowledge we have on evacuee behavior in times of crisis into reliable quantitative measures of the timing of evacuee mobilization, notably by distance from the source of the hazard. Specific evacuation models are referenced and categorized by method. Incorporation of evacuation model findings into the definition of emergency planning zone boundaries is also discussed.

  14. Emergency evacuation : how better interior design can improve passenger flow

    NARCIS (Netherlands)

    Boer, L.C.; Skjong, R.

    2001-01-01

    The paper presents some conclusions from the EU basic research project "MEPdesign" relevant for design of ship interiors. The findings are discussed with regard to passenger flow as a function of design parameters. The paper explains that current evacuation analyses may be overly optimistic. The

  15. Precision of ingestion time and evacuation predictors for individual prey in stomachs of predatory fishes

    DEFF Research Database (Denmark)

    Andersen, Niels Gerner; Beyer, Jan

    2008-01-01

    merlangus), Atlantic cod (Gadus morhua), and saithe (pollock) (Pollachius virens). Deriving the variance of gastric evacuation rate, evacuation time, and remaining prey mass, the study also established a basis for statistical analyses of the results obtained from laboratory experiments on gastric evacuation...

  16. Variable population exposure and distributed travel speeds in least-cost tsunami evacuation modelling

    Science.gov (United States)

    Fraser, Stuart A.; Wood, Nathan J.; Johnston, David A.; Leonard, Graham S.; Greening, Paul D.; Rossetto, Tiziana

    2014-01-01

    Evacuation of the population from a tsunami hazard zone is vital to reduce life-loss due to inundation. Geospatial least-cost distance modelling provides one approach to assessing tsunami evacuation potential. Previous models have generally used two static exposure scenarios and fixed travel speeds to represent population movement. Some analyses have assumed immediate departure or a common evacuation departure time for all exposed population. Here, a method is proposed to incorporate time-variable exposure, distributed travel speeds, and uncertain evacuation departure time into an existing anisotropic least-cost path distance framework. The method is demonstrated for hypothetical local-source tsunami evacuation in Napier City, Hawke's Bay, New Zealand. There is significant diurnal variation in pedestrian evacuation potential at the suburb level, although the total number of people unable to evacuate is stable across all scenarios. Whilst some fixed travel speeds approximate a distributed speed approach, others may overestimate evacuation potential. The impact of evacuation departure time is a significant contributor to total evacuation time. This method improves least-cost modelling of evacuation dynamics for evacuation planning, casualty modelling, and development of emergency response training scenarios. However, it requires detailed exposure data, which may preclude its use in many situations.

  17. Measurements and Calculations of the Effects of Distortions in the Collector Surface on Efficiencies of Umbrella-Type Solar Collectors

    Science.gov (United States)

    Bond, Victor R.

    1961-01-01

    The meridional tensions along the ribs in a Mylar-covered umbrella-type solar collector produce a distortion in the reflecting surface that is detrimental to the image in the focal plane. The investigation reported herein was made to obtain measured and calculated geometric efficiencies of umbrella-type collectors as affected by these surface distortions. These studies show that if the tension transverse to the ribs is increased relative to the meridional tensions, the distortion is reduced and higher efficiencies can be attained, and if the transverse tension is small, the number of ribs in the collector must be increased for higher efficiencies.

  18. Performance of wood in a do-it-yourself solar collector

    Science.gov (United States)

    G. E. Sherwood; W. A. Gatz

    1979-01-01

    Six variations of a do-it-yourself solar collector design were constructed and exposed under stagnation conditions for 1 year; collectors were basically closed boxes without air circulation. Temperature in each collector was recorded throughout the test period and the effect of these temperatures on the wood framing and plywood in the collectors was estimated...

  19. CLEAR (Calculates Logical Evacuation And Response): A Generic Transportation Network Model for the Calculation of Evacuation Time Estimates

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, M. P.; Urbanik, II, T.; Desrosiers, A. E.

    1982-03-01

    This paper describes the methodology and application of the computer model CLEAR (Calculates Logical Evacuation And Response) which estimates the time required for a specific population density and distribution to evacuate an area using a specific transportation network. The CLEAR model simulates vehicle departure and movement on a transportation network according to the conditions and consequences of traffic flow. These include handling vehicles at intersecting road segments, calculating the velocity of travel on a road segment as a function of its vehicle density, and accounting for the delay of vehicles in traffic queues. The program also models the distribution of times required by individuals to prepare for an evacuation. In order to test its accuracy, the CLEAR model was used to estimate evacuatlon tlmes for the emergency planning zone surrounding the Beaver Valley Nuclear Power Plant. The Beaver Valley site was selected because evacuation time estimates had previously been prepared by the licensee, Duquesne Light, as well as by the Federal Emergency Management Agency and the Pennsylvania Emergency Management Agency. A lack of documentation prevented a detailed comparison of the estimates based on the CLEAR model and those obtained by Duquesne Light. However, the CLEAR model results compared favorably with the estimates prepared by the other two agencies.

  20. Unaccompanied evacuation and adult mortality: evaluating the finnish policy of evacuating children to foster care during World War II.

    Science.gov (United States)

    Santavirta, Torsten

    2014-09-01

    I examined associations between evacuation of Finnish children to temporary foster care in Sweden during World War II and all-cause mortality between ages 38 and 78 years. I used a Cox proportional hazards model to estimate mortality risk according to whether the individual was evacuated during childhood or not. I used within-sibling analysis to control for all unobserved socioeconomic and genetic characteristics shared among siblings. Individual-level data for Finnish cohorts born in 1933 to 1944 were derived from wartime government records, Finnish census data from 1950 and 1970, and death cause registry from 1971 to 2011. I found no statistically significant association between evacuation and all-cause mortality when all exposed individuals were included in the analysis. However, subgroup analysis showed that men evacuated before age 4 years had a 1.31 higher mortality risk (95% confidence interval = 1.01, 1.69) than their nonevacuated counterparts. In the aggregate, individuals do not have elevated mortality risk as a consequence of foster care during early childhood owing to the onset of sudden external shocks (e.g., wars).

  1. Solar Thermal AIR Collector Based on New Type Selective Coating

    National Research Council Canada - National Science Library

    Musiy, R.Y; Midyana, G.G; Makitra, R.G; Vasyutin, J.M; Khovanets, G.I; Zaborowskiy, A.B

    2014-01-01

    Based on the best for optical performance and selective coating solar thermal air collector, which operates by solar power on the principle of simultaneous ventilation and heating facilities, is designed...

  2. Mathematical Modeling of Dual Intake Transparent Transpired Solar Collector

    Directory of Open Access Journals (Sweden)

    Thomas Semenou

    2015-01-01

    Full Text Available Nowadays, in several types of commercial or institutional buildings, a significant rise of transpired solar collectors used to preheat the fresh air of the building can be observed. Nevertheless, when the air mass flow rate is low, the collector efficiency collapses and a large amount of energy remains unused. This paper presents a simple yet effective mathematical model of a transparent transpired solar collector (TTC with dual intake in order to remove stagnation problems in the plenum and ensure a better thermal efficiency and more heat recovery. A thermal model and a pressure loss model were developed. Then, the combined model was validated with experimental data from the Solar Rating and Certification Corporation (SRCC. The results show that the collector efficiency can be up to 70% and even 80% regardless of operating conditions. The temperature gain is able to reach 20°K when the solar irradiation is high.

  3. Thermal Performance of an Annealed Pyrolytic Graphite Solar Collector

    Science.gov (United States)

    Jaworske, Donald A.; Hornacek, Jennifer

    2002-01-01

    A solar collector having the combined properties of high solar absorptance, low infrared emittance, and high thermal conductivity is needed for applications where solar energy is to be absorbed and transported for use in minisatellites. Such a solar collector may be used with a low temperature differential heat engine to provide power or with a thermal bus for thermal switching applications. One concept being considered for the solar collector is an Al2O3 cermet coating applied to a thermal conductivity enhanced polished aluminum substrate. The cermet coating provides high solar absorptance and the polished aluminum provides low infrared emittance. Annealed pyrolytic graphite embedded in the aluminum substrate provides enhanced thermal conductivity. The as-measured thermal performance of an annealed pyrolytic graphite thermal conductivity enhanced polished aluminum solar collector, coated with a cermet coating, will be presented.

  4. [Naturalists, collectors and theoreticians of museology].

    Science.gov (United States)

    Arabas, Iwona

    2009-01-01

    The origins of the contemporary collectorship dates from times when the sameness of art and science was commonly accepted. In those days relics of the ancient past and natural individuals of newly discovered lands were presented at the same time. Cosmological character of the collections manifested the tenacity of recognition and representation of the surrounding reality. A great impact on completion of collections of curiosities in Europe had Netherlands, and in the basin of Baltic Sea a remarkable significance was gained by Hanseatic Gdańsk. Collections of Jakub Breyn, Jakub Klein and Gotfryd Reyger became famous then. In the same way were imported individuals for Anna Jabłonowska that composed one of the most interesting European collections. In course of time merging such a great multiplicity of collections was beyond collectors' power and museum pieces from collections of curiosities were parcelled out. It was a real beginning of specialistic museums. A role of museum for science results from its function of methodical organizing collections that can be used by research workers. However, although the aims of scientific and museum centres are different, they come together on the occasion of museum recognition works when museums' workers borrow essential knowledge and methods from resources of science, and scientists search for useful research materials in museum resources.

  5. The transient thermal response of a tubular solar collector

    Science.gov (United States)

    Lansing, F. L.

    1976-01-01

    A special analytical solution is provided for the timewise response of the circulating fluid temperatures when a sudden step change of the input solar radiation is imposed and remains constant thereafter. An example which demonstrates the transient temperatures at the exit section of a single collector with two different flow patterns is presented. This study is used to supplement some numerical solutions to provide a fairly complete coverage for this type of solar collector.

  6. Proceedings of the solar thermal concentrating collector technology symposium

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, B.P.; Kreith, F. (eds.)

    1978-08-01

    The purpose of the symposium was to review the current status of the concentrating collector technology, to disseminate the information gained from experience in operating solar systems, and to highlight the significant areas of technology development that must be vigorously pursued to foster early commercialization of concentrating solar collectors. Separate abstracts were prepared for thirteen invited papers and working group summaries. Two papers were previously abstracted for EDB.

  7. Means of increasing efficiency of CPC solar energy collector

    Science.gov (United States)

    Chao, B.T.; Rabl, A.

    1975-06-27

    A device is provided for improving the thermal efficiency of a cylindrical radiant energy collector. A channel is placed next to and in close proximity to the nonreflective side of an energy reflective wall of a cylindrical collector. A coolant is piped through the channel and removes a portion of the nonreflective energy incident on the wall which is absorbed by the wall. The energy transferred to the coolant may be utilized in a useful manner.

  8. Shape Control of Solar Collectors Using Shape Memory Alloy Actuators

    Science.gov (United States)

    Lobitz, D. W.; Grossman, J. W.; Allen, J. J.; Rice, T. M.; Liang, C.; Davidson, F. M.

    1996-01-01

    Solar collectors that are focused on a central receiver are designed with a mechanism for defocusing the collector or disabling it by turning it out of the path of the sun's rays. This is required to avoid damaging the receiver during periods of inoperability. In either of these two cases a fail-safe operation is very desirable where during power outages the collector passively goes to its defocused or deactivated state. This paper is principally concerned with focusing and defocusing the collector in a fail-safe manner using shape memory alloy actuators. Shape memory alloys are well suited to this application in that once calibrated the actuators can be operated in an on/off mode using a minimal amount of electric power. Also, in contrast to other smart materials that were investigated for this application, shape memory alloys are capable of providing enough stroke at the appropriate force levels to focus the collector. Design and analysis details presented, along with comparisons to test data taken from an actual prototype, demonstrate that the collector can be repeatedly focused and defocused within accuracies required by typical solar energy systems. In this paper the design, analysis and testing of a solar collector which is deformed into its desired shape by shape memory alloy actuators is presented. Computations indicate collector shapes much closer to spherical and with smaller focal lengths can be achieved by moving the actuators inward to a radius of approximately 6 inches. This would require actuators with considerably more stroke and some alternate SMA actuators are currently under consideration. Whatever SMA actuator is finally chosen for this application, repeatability and fatigue tests will be required to investigate the long term performance of the actuator.

  9. Thermal efficiency of single-pass solar air collector

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Zamry; Ibarahim, Zahari; Yatim, Baharudin [School of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor Darul Ehsan (Malaysia); Ruslan, Mohd Hafidz [Solar Energy Research Institute (SERI), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor Darul Ehsan (Malaysia)

    2013-11-27

    Efficiency of a finned single-pass solar air collector was studied. This paper presents the experimental study to investigate the effect of solar radiation and mass flow rate on efficiency. The fins attached at the back of absorbing plate to improve the thermal efficiency of the system. The results show that the efficiency is increased proportional to solar radiation and mass flow rate. Efficiency of the collector archived steady state when reach to certain value or can be said the maximum performance.

  10. Dual curvature acoustically damped concentrating collector. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Smith, G.A.; Rausch, R.A.

    1980-05-01

    A development program was conducted to investigate the design and performance parameters of a novel, dual curvature, concentrating solar collector. The reflector of the solar collector is achieved with a stretched-film reflective surface that approximates a hyperbolic paraboloid and is capable of line-focusing at concentration ratios ranging from 10 to 20X. A prototype collector was designed based on analytical and experimental component trade-off activities as well as economic analyses of solar thermal heating and cooling systems incorporating this type of collector. A prototype collector incorporating six 0.66 x 1.22 m (2 x 4 ft) was fabricated and subjected to a limited thermal efficiency test program. A peak efficiency of 36% at 121/sup 0/C (250/sup 0/F) was achieved based upon the gross aperture area. Commercialization activities were conducted, including estimated production costs of $134.44/m/sup 2/ ($12.49/ft/sup 2/) for the collector assembly (including a local suntracker and controls) and $24.33/m/sup 2/ ($2.26/ft/sup 2/) for the reflector subassembly.

  11. EFFICIENCY AND LIFETIME OF SOLAR COLLECTORS FOR SOLAR HEATING PLANTS

    DEFF Research Database (Denmark)

    The 12.5 m² flat plate solar collector HT, today marketed by Arcon Solvarme A/S, has been used in solar heating plants in Scandinavia since 1983. The collector is designed to operate in a temperature interval between 40°C and 90°C. The efficiency of the collector has been strongly improved since...... it was introduced on the market. The paper will present the increase of the efficiency of the collector due to technical improvements since 1983. Further, measurements from the spring of 2009 of the efficiency of two HT collectors, which have been in operation in the solar heating plant Ottrupgaard, Skørping......, Denmark since 1994 with a constant high flow rate and in the solar heating plant Marstal, Denmark since 1996 with a variable flow rate, will be presented. The efficiencies will be compared to the efficiencies of the collectors when they were first installed in the solar heating plants. The measurements...

  12. EFFICIENCY AND LIFETIME OF SOLAR COLLECTORS FOR SOLAR HEATING PLANTS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Chen, Ziqian; Furbo, Simon

    2009-01-01

    The 12.5 m² flat plate solar collector HT, today marketed by Arcon Solvarme A/S, has been used in solar heating plants in Scandinavia since 1983. The collector is designed to operate in a temperature interval between 40°C and 90°C. The efficiency of the collector has been strongly improved since...... it was introduced on the market. The paper will present the increase of the efficiency of the collector due to technical improvements since 1983. Further, measurements from the spring of 2009 of the efficiency of two HT collectors, which have been in operation in the solar heating plant Ottrupgaard, Skørping......, Denmark since 1994 with a constant high flow rate and in the solar heating plant Marstal, Denmark since 1996 with a variable flow rate, will be presented. The efficiencies will be compared to the efficiencies of the collectors when they were first installed in the solar heating plants. The measurements...

  13. An improved dynamic test method for solar collectors

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Wang, Zhifeng; Fan, Jianhua

    2012-01-01

    A comprehensive improvement of the mathematical model for the so called transfer function method is presented in this study. This improved transfer function method can estimate the traditional solar collector parameters such as zero loss coefficient and heat loss coefficient. Two new collector...... parameters t and mfCf are obtained. t is a time scale parameter which can indicate the heat transfer ability of the solar collector. mfCf can be used to calculate the fluid volume content in the solar collector or to validate the regression process by comparing it to the physical fluid volume content...... for the second-order differential term with 6–9min as the best averaging time interval. The measured and predicted collector power output of the solar collector are compared during a test of 13days continuously both for the ITF method and the QDT method. The maximum and averaging error is 53.87W/m2 and 5.22W/m2...

  14. An investigation on the performance characteristics of solar flat plate collector with different selective surface coatings

    OpenAIRE

    Madhukeshwara N., E. S. Prakash

    2012-01-01

    In the present work, investigations are made to study performance characteristics of solar flat plate collector with different selective surface coatings. Flat plate collector is one of the important solar energy trapping device which uses air or water as working fluid. Of the many solar collector concepts presently being developed, the relative simple flat plate solar collector has found the widest application so far. Its characteristics are known, and compared with other collector types, it...

  15. Coloured solar collectors. Phase II : from laboratory samples to collector prototypes. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, A.; Roecker, Ch.; Chambrier, E. de; Munari Probst, M.

    2007-07-01

    This illustrated final report for the Swiss Federal Office of Energy (SFOE) deals with the second phase of a project concerning the architectural integration of glazed solar collectors into the facades of buildings for heat production. The factors that limit the integration of photovoltaic panels in facades are discussed. The authors state that, for a convincing demonstration, sufficiently large samples and high quality levels are needed. The sol-gel deposition of the multi-layered coatings on A4-sized glass panes demonstrated in the laboratory by EPFL-LESO are discussed. The coatings produced exhibit a coloured reflection in combination with a high solar transmittance, a homogenous appearance, and are free of visible defects. Film hardening by UV exposure is discussed: This should result in the speeding up of the sol-gel process and thus save energy, thereby significantly reducing costs. Collaboration with industry is discussed in which full-scale glass panes are to be coated with novel multiple layers. The novel glazing is to be integrated into first prototype collectors. The manufacturing and test processes for the prototypes manufactured are discussed in detail.

  16. Effect of openings collectors and solar irradiance on the thermal efficiency of flat plate-finned collector for indirect-type passive solar dryer

    Science.gov (United States)

    Batubara, Fatimah; Dina, Sari Farah; Klaudia Kathryn Y., M.; Turmuzi, M.; Siregar, Fitri; Panjaitan, Nora

    2017-06-01

    Research on the effect of openings solar collector and solar irradiance to thermal efficiency has been done. Solar collector by flat plate-finned type consists of 3 ply insulator namely wood, Styrofoam and Rockwool with thickness respectively are 10 mm, 25 mm and 50 mm. Absorber plate made of aluminum sheet with thickness of 0.30 mm, painted by black-doff. Installation of 19 units fins (length x height x thickness: 1000x20x10 mm) on the collector will increase surface area of absorber so it can receive much more solar energy. The solar collector cover is made of glass (thickness of 5 mm). During the research, the solar irradiance and temperature of collector are measured and recorded every five minutes. Temperature measurement performed on the surface of the absorber plate, inside of collector, surface cover and the outer side insulator (plywood). This data is used to calculate the heat loss due to conduction, convection and radiation on the collector. Openings of collectors vary as follows: 100%, 75%, 15% and 0% (total enclosed). The data collecting was conducted from 09.00 am to 17.00 pm and triplicates. The collector thermal efficiency calculated based on the ratio of the amount of heat received to the solar irradiance absorbed. The results show that each of openings solar collector has different solar irradiance (because it was done on a different day) which is in units of W/m2: 390 (100% open), 376 (75% open), 429 (15% open), and 359 (totally enclosed). The highest thermal efficiency is in openings variation of 15% opened. These results indicate that the efficiency of the collector is influenced by the solar irradiance received by the collector and the temperature on the collector plate. The highest thermal efficiency is in variation of openings 15%. These indicate that the efficiency of the collector was influenced by solar irradiance received by the collector and openings of the collector plate.

  17. Community disruptions and business costs for distant tsunami evacuations using maximum versus scenario-based zones

    Science.gov (United States)

    Wood, Nathan J.; Wilson, Rick I.; Ratliff, Jamie L.; Peters, Jeff; MacMullan, Ed; Krebs, Tessa; Shoaf, Kimberley; Miller, Kevin

    2017-01-01

    Well-executed evacuations are key to minimizing loss of life from tsunamis, yet they also disrupt communities and business productivity in the process. Most coastal communities implement evacuations based on a previously delineated maximum-inundation zone that integrates zones from multiple tsunami sources. To support consistent evacuation planning that protects lives but attempts to minimize community disruptions, we explore the implications of scenario-based evacuation procedures and use the California (USA) coastline as our case study. We focus on the land in coastal communities that is in maximum-evacuation zones, but is not expected to be flooded by a tsunami generated by a Chilean earthquake scenario. Results suggest that a scenario-based evacuation could greatly reduce the number of residents and employees that would be advised to evacuate for 24–36 h (178,646 and 159,271 fewer individuals, respectively) and these reductions are concentrated primarily in three counties for this scenario. Private evacuation spending is estimated to be greater than public expenditures for operating shelters in the area of potential over-evacuations ($13 million compared to $1 million for a 1.5-day evacuation). Short-term disruption costs for businesses in the area of potential over-evacuation are approximately $122 million for a 1.5-day evacuation, with one-third of this cost associated with manufacturing, suggesting that some disruption costs may be recouped over time with increased short-term production. There are many businesses and organizations in this area that contain individuals with limited mobility or access and functional needs that may have substantial evacuation challenges. This study demonstrates and discusses the difficulties of tsunami-evacuation decision-making for relatively small to moderate events faced by emergency managers, not only in California but in coastal communities throughout the world.

  18. Sampling efficiency of the Moore egg collector

    Science.gov (United States)

    Worthington, Thomas A.; Brewer, Shannon K.; Grabowski, Timothy B.; Mueller, Julia

    2013-01-01

    Quantitative studies focusing on the collection of semibuoyant fish eggs, which are associated with a pelagic broadcast-spawning reproductive strategy, are often conducted to evaluate reproductive success. Many of the fishes in this reproductive guild have suffered significant reductions in range and abundance. However, the efficiency of the sampling gear used to evaluate reproduction is often unknown and renders interpretation of the data from these studies difficult. Our objective was to assess the efficiency of a modified Moore egg collector (MEC) using field and laboratory trials. Gear efficiency was assessed by releasing a known quantity of gellan beads with a specific gravity similar to that of eggs from representatives of this reproductive guild (e.g., the Arkansas River Shiner Notropis girardi) into an outdoor flume and recording recaptures. We also used field trials to determine how discharge and release location influenced gear efficiency given current methodological approaches. The flume trials indicated that gear efficiency ranged between 0.0% and 9.5% (n = 57) in a simple 1.83-m-wide channel and was positively related to discharge. Efficiency in the field trials was lower, ranging between 0.0% and 3.6%, and was negatively related to bead release distance from the MEC and discharge. The flume trials indicated that the gellan beads were not distributed uniformly across the channel, although aggregation was reduced at higher discharges. This clustering of passively drifting particles should be considered when selecting placement sites for an MEC; further, the use of multiple devices may be warranted in channels with multiple areas of concentrated flow.

  19. Advanced Hybrid Particulate Collector Project Management Plan

    Energy Technology Data Exchange (ETDEWEB)

    Miller, S.J.

    1995-11-01

    As the consumption of energy increases, its impact on ambient air quality has become a significant concern. Recent studies indicate that fine particles from coal combustion cause health problems as well as atmospheric visibility impairment. These problems are further compounded by the concentration of hazardous trace elements such as mercury, cadmium, selenium, and arsenic in fine particles. Therefore, a current need exists to develop superior, but economical, methods to control emissions of fine particles. Since most of the toxic metals present in coal will be in particulate form, a high level of fine- particle collection appears to be the best method of overall air toxics control. However, over 50% of mercury and a portion of selenium emissions are in vapor form and cannot be collected in particulate control devices. Therefore, this project will focus on developing technology not only to provide ultrahigh collection efficiency of particulate air toxic emissions, but also to capture vapor- phase trace metals such as mercury and selenium. Currently, the primary state-of-the-art technologies for particulate control are fabric filters (baghouses) and electrostatic precipitators (ESPs). However, they both have limitations that prevent them from achieving ultrahigh collection of fine particulate matter and vapor-phase trace metals. The objective of this project is to develop a highly reliable advanced hybrid particulate collector (AHPC) that can provide > 99.99 % particulate collection efficiency for all particle sizes between 0.01 and 50 14m, is applicable for use with all U.S. coals, and is cost-0443competitive with existing technologies. Phase I of the project is organized into three tasks: Task I - Project Management, Reporting, and Subcontract Consulting Task 2 - Modeling, Design, and Construction of 200-acfm AHPC Model Task 3 - Experimental Testing and Subcontract Consulting

  20. Modelling social identification and helping in evacuation simulation

    CERN Document Server

    von Sivers, I; Künzner, F; Köster, G; Drury, J; Philippides, A; Neckel, T; Bungartz, H -J

    2016-01-01

    Social scientists have criticised computer models of pedestrian streams for their treatment of psychological crowds as mere aggregations of individuals. Indeed most models for evacuation dynamics use analogies from physics where pedestrians are considered as particles. Although this ensures that the results of the simulation match important physical phenomena, such as the deceleration of the crowd with increasing density, social phenomena such as group processes are ignored. In particular, people in a crowd have social identities and share those social identities with the others in the crowd. The process of self categorisation determines norms within the crowd and influences how people will behave in evacuation situations. We formulate the application of social identity in pedestrian simulation algorithmically. The goal is to examine whether it is possible to carry over the psychological model to computer models of pedestrian motion so that simulation results correspond to observations from crowd psychology. ...

  1. Modeling Evacuation of Emergency Vehicles by Cellular Automata Models

    Science.gov (United States)

    Moussa, Najem

    An evacuation of the emergency vehicle (EV) from an origin point (e.g., accident location) to a destination point (e.g., hospital) in lower and higher congestions is simulated using city cellular automata models. We find that the mean speed of the EV and its arrival time all depend enormously on the cars density, the route length of the EV and the turn capability of the cars. Dangerous situations that occurred during the evacuation of the EV are also investigated. By allowing high turning capabilities to cars, considerable improvements are obtained. Indeed, the EV mean speed is enhanced and its arrival time is optimized. Moreover, at relatively high density, a significant reduction of the risk of accident is expected.

  2. Tsunami Evacuation Exercises: the Case of Heraklion, Crete Isl., Greece

    Science.gov (United States)

    Triantafyllou, I.; Charalampakis, M.; Bocchini, G. M.; Novikova, T.; Papadopoulos, G. A.

    2016-12-01

    Effective tsunami evacuation requires appropriate awareness as regards good shelters selection. Field exercises may improve public awareness. A field exercise was organized in Heraklion, Crete Isl., in 2016. The area is part of the Hellenic Arc which is the most active structure in the Mediterranean. Large earthquakes triggered tsunamis that hit Heraklion in the past, such in AD 1303. After selecting various fault models, simulation of the 1303 tsunami showed important inundation zone in Heraklion. For the exercise needs a team of 30 volunteers was divided in 3 groups of 10 people each. Everyone was equipped with a mobile phone and a GPS device. The 3 groups were gathered in 3 coastal spots Heraklion situated 400 m apart each other. The scenario was that immediately after receiving in their mobile a tsunami warning message they will set on their personal GPS device and start evacuating inland on the best way they believed to do so. In each group, only 5 out of 10 volunteers were notified beforehand that the Eleftherias Square, located inland at distance satisfying evacuation needs in case of repeat of the 1303 tsunami, would be a good shelter to go. Using the Road Graph Plugin of QGIS, we calculated the shortest path distances which found equal to 800, 700 and 680 m. Adopting average velocity of 3 km/h we found that these distances can be covered within 18, 16 and 15 min, respectively. The routes towards the settlement spots as well as the times needed to arrive there by each one of the 30 volunteers were recorded by their personal GPS devices. The processing of the GPS tracks and their comparison with the theoretical routes and times showed good evacuation performance which is encouraging for the next phases of the Heraklion tsunami hazard mitigation program. This is contribution to the EU-FP7 projects ZIP (Zooming In between Plates, grant no: 604713, 2013) and ASTARTE (Assessment, Strategy And Risk Reduction for Tsunamis in Europe), grant no: 603839, 2013.

  3. A Guide for Emergency Evacuation Management and Operations

    Science.gov (United States)

    1981-02-01

    coordinators or assistants for medical care and public health (including sanitation and mortuary services). To plan for and execute evacuation operations...conversion of schols, hotels and other facilities to temporary care facilities; * Plan to coordinate mortuary services for interment of the dead, grave...disinfectants; packaged cleaning towels and toilet paper; and chemical toilets where possible (with chemicals). 20-4L 0; 20.4 OTHER SUPPLIES The following items

  4. The science between tsunami science and evacuation decisions

    Science.gov (United States)

    McCaughey, J.; Dewi, P. R.; Mundzir, I.; Rosemary, R.; Safrina, L.; Daly, P.; Patt, A.

    2014-12-01

    The science of rare natural hazards provides us an opportunity that our ancestors lacked: the chance to learn what hazards we could face, and how reliable any particular precursor may or may not be. Connecting hazard science to societal learning is far too complex a challenge for our intuitions to be of much use. Instead, we need to use evidence - the science of science communication - to identify what actually works. As practitioners, we first worked with NGOs and local governments in coastal Sumatran communities to develop tsunami evacuation guidance that is consistent with the science of tsunamis and suitable for the communities that face the threat. This work identified important practical questions that social science can address: how do people decide whether to evacuate, and how do hazard knowledge and experience influence this? How acceptable are false alarms? What modes of communicating tsunami science and its uncertainties may lead to greater willingness to evacuate, and greater acceptance of false alarms? Which parts of the vast body of research on communication, risk perception, and decision-making might be significant in these contexts? We are beginning research at the household level that will address these questions and feed back into our continuing science-communication practice.

  5. Evacuation of Pedestrians with Two Motion Modes for Panic System.

    Science.gov (United States)

    Zou, You; Xie, Jiarong; Wang, Binghong

    2016-01-01

    In this paper, we have captured an underlying mechanism of emergence of collective panic in pedestrian evacuations by using a modification of the lattice-gas model. We classify the motion of pedestrians into two modes according to their moods. One is gentle (mode I), the other is flustered (mode II). First, to research the cause for crowd, we fix the motion modes of pedestrians and increase the proportion of pedestrians with motion mode II (ρII). The simulation results show that the pedestrians with motion mode II are lack of evacuation efficiency and cause more casualties. Further, we use the SIS (susceptible-infective-susceptible) model to describe the spreading of the panic mood. The system can be in the high-mix state when the infection probability λ is greater than a fuzzy threshold. In addition, the distances S from wounded people to the exit are researched, the number of wounded people gets maximum at the internal S = 5∼10, which is independent of ρII and λ. This research can help us to understand and prevent the emergence of collective panic and reduce wounds in the real evacuation.

  6. Evacuation of Pedestrians with Two Motion Modes for Panic System.

    Directory of Open Access Journals (Sweden)

    You Zou

    Full Text Available In this paper, we have captured an underlying mechanism of emergence of collective panic in pedestrian evacuations by using a modification of the lattice-gas model. We classify the motion of pedestrians into two modes according to their moods. One is gentle (mode I, the other is flustered (mode II. First, to research the cause for crowd, we fix the motion modes of pedestrians and increase the proportion of pedestrians with motion mode II (ρII. The simulation results show that the pedestrians with motion mode II are lack of evacuation efficiency and cause more casualties. Further, we use the SIS (susceptible-infective-susceptible model to describe the spreading of the panic mood. The system can be in the high-mix state when the infection probability λ is greater than a fuzzy threshold. In addition, the distances S from wounded people to the exit are researched, the number of wounded people gets maximum at the internal S = 5∼10, which is independent of ρII and λ. This research can help us to understand and prevent the emergence of collective panic and reduce wounds in the real evacuation.

  7. Mass Casualty Incident Response and Aeromedical Evacuation in Antarctica

    Directory of Open Access Journals (Sweden)

    Mills, Christopher N

    2011-02-01

    Full Text Available Antarctica is one of the most remote regions on Earth. Mass casualty incident (MCI responses in Antarctica are prone to complications from multiple environmental and operational challenges. This review of the current status of MCI risks and response strategies for Antarctica focuses on aeromedical evacuation, a critical component of many possible MCI scenarios. Extreme cold and weather, a lack of medical resources and a multitude of disparate international bases all exert unique demands on MCI response planning. Increasing cruise ship traffic is also escalating the risk of MCI occurrence. To be successful, MCI response must be well coordinated and undertaken by trained rescuers, especially in the setting of Antarctica. Helicopter rescue or aeromedical evacuation of victims to off-continent facilities may be necessary. Currently, military forces have the greatest capacity for mass air evacuation. Specific risks that are likely to occur include structure collapses, vehicle incapacitations, vehicle crashes and fires. All of these events pose concomitant risks of hypothermia among both victims and rescuers. Antarctica’s unique environment requires flexible yet robust MCI response planning among the many entities in operation on the continent. [West J Emerg Med. 2011;12(1:37-42.

  8. Modeling pedestrian evacuation by means of game theory

    Science.gov (United States)

    Shi, Dongmei; Zhang, Wenyao; Wang, Binghong

    2017-04-01

    Pedestrian evacuation is studied based on a modified lattice model. The payoff matrix in this model represents the complicated interactions between selfish individuals, and the mean force imposed on an individual is given by considering the impacts of neighbors, walls, and defector herding. Each passer-by moves to his selected location according to the Fermi function, and the average velocity of pedestrian flow is defined as a function of the motion rule. Two pedestrian types are included: cooperators, who adhere to the evacuation instructions; and defectors, who ignore the rules and act individually. It is observed that the escape time increases as fear degree increases, and the system remains smooth for a low fear degree, but exhibits three stages for a high fear degree. We prove that the fear degree determines the dynamics of this system, and the initial density of cooperators has a negligible impact. The system experiences three phases, a single phase of cooperator, a mixed two-phase pedestrian, and a single phase of defector sequentially as the fear degree upgrades. The phase transition has been proven basically robust to the changes of empty site contribution, wall’s pressure, and noise amplitude in the motion rule. It is further shown that pedestrians derive the greatest benefit from overall cooperation, but are trapped in the worst situation if they are all defectors. Dynamics of pedestrian evacuation.

  9. Measuring and modeling behavioral decision dynamics in collective evacuation.

    Directory of Open Access Journals (Sweden)

    Jean M Carlson

    Full Text Available Identifying and quantifying factors influencing human decision making remains an outstanding challenge, impacting the performance and predictability of social and technological systems. In many cases, system failures are traced to human factors including congestion, overload, miscommunication, and delays. Here we report results of a behavioral network science experiment, targeting decision making in a natural disaster. In a controlled laboratory setting, our results quantify several key factors influencing individual evacuation decision making in a controlled laboratory setting. The experiment includes tensions between broadcast and peer-to-peer information, and contrasts the effects of temporal urgency associated with the imminence of the disaster and the effects of limited shelter capacity for evacuees. Based on empirical measurements of the cumulative rate of evacuations as a function of the instantaneous disaster likelihood, we develop a quantitative model for decision making that captures remarkably well the main features of observed collective behavior across many different scenarios. Moreover, this model captures the sensitivity of individual- and population-level decision behaviors to external pressures, and systematic deviations from the model provide meaningful estimates of variability in the collective response. Identification of robust methods for quantifying human decisions in the face of risk has implications for policy in disasters and other threat scenarios, specifically the development and testing of robust strategies for training and control of evacuations that account for human behavior and network topologies.

  10. Controlled evacuation using the biocompatible and energy efficient microfluidic ejector.

    Science.gov (United States)

    Lad, V N; Ralekar, Swati

    2016-10-01

    Development of controlled vacuum is having many applications in the realm of biotechnology, cell transfer, gene therapy, biomedical engineering and other engineering activities involving separation or chemical reactions. Here we show the controlled vacuum generation through a biocompatible, energy efficient, low-cost and flexible miniature device. We have designed and fabricated microfluidic devices from polydimethylsiloxane which are capable of producing vacuum at a highly controlled rate by using water as a motive fluid. Scrupulous removal of infected fluid/body fluid from the internal hemorrhage affected parts during surgical operations, gene manipulation, cell sorting, and other biomedical activities require complete isolation of the delicate cells or tissues adjacent to the targeted location. We demonstrate the potential of the miniature device to obtain controlled evacuation without the use of highly pressurized motive fluids. Water has been used as a motive liquid to eject vapor and liquid at ambient conditions through the microfluidic devices prepared using a low-cost fabrication method. The proposed miniature device may find applications in vacuum generation especially where the controlled rate of evacuation, and limited vacuum generation are of utmost importance in order to precisely protect the cells in the nearby region of the targeted evacuated area.

  11. Surgical smoke evacuation guidelines: compliance among perioperative nurses.

    Science.gov (United States)

    Ball, Kay

    2010-08-01

    More than 500,000 health care workers are exposed to surgical smoke every year. Toxic gases create an offensive odor, small particulate matter causes respiratory complications, and pathogens may be transmitted in the surgical smoke to the surgical team. Previous research notes that perioperative nurses do not consistently follow smoke evacuation recommendations. The purpose of this study was to determine key indicators that are associated with compliance with smoke evacuation recommendations. Data from a web-based survey completed by 777 nurse members of AORN were analyzed to examine the relationship between the key indicators and compliance with smoke evacuation recommendations. Major findings were that specific key indicators influencing compliance include increased knowledge and training, positive perceptions about the complexity of the recommendations, and increased specialization, interconnectedness, and leadership support in larger facilities. Education programs can be developed that directly address these key predictors so that a surgical environment free from surgical smoke is promoted. 2010 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  12. Modeling Evacuate versus Shelter-in-Place Decisions in Wildfires

    Directory of Open Access Journals (Sweden)

    Frank A. Drews

    2011-09-01

    Full Text Available Improving community resiliency to wildfire is a challenging problem in the face of ongoing development in fire-prone regions. Evacuation and shelter-in-place are the primary options for reducing wildfire casualties, but it can be difficult to determine which option offers the most protection in urgent scenarios. Although guidelines and policies have been proposed to inform this decision, a formal approach to evaluating protective options would help advance protective-action theory. We present an optimization model based on the premise that protecting a community can be viewed as assigning threatened households to one of three actions: evacuation, shelter-in-refuge, or shelter-in-home. While evacuation generally offers the highest level of life protection, it can place residents at greater risk when little time is available. This leads to complex trade-offs involving expected fire intensity, available time, and the quality and accessibility of in-place shelter. An application of the model is presented to illustrate a range of issues that can arise across scenarios.

  13. Impact of Smoke Evacuation on Patient Experience During Mohs Surgery.

    Science.gov (United States)

    Yonan, Yousif; Ochoa, Shari

    2017-11-01

    There have been several investigations into possible health risks of surgical smoke exposure, and it has previously been associated with harboring pathogens and carcinogens. Patients in the authors' practice have expressed that the odor from the smoke created by electrosurgical equipment is unpleasant. The authors sought to determine if smoke evacuation decreases patient perception of smoke created by electrosurgery during Mohs surgery and if it subsequently improves patient satisfaction with their surgical experience by minimizing the associated odor. Thirty patients were enrolled in this comparative trial. Smoke evacuation was used during closure but not during Mohs stages. Patients were queried regarding their experience and preferences during and at the end of the procedure. 100% of patients reported the perception of a burning odor during removal of Mohs stages, compared with 40% reporting the perception of a burning odor during closure. During the Mohs stages, 66.6% of patients reported the odor as unpleasant compared with 16.6% of patients during closure. There were no statistically significant differences in patient perceptions when stratified by age, sex, or surgical site. The authors believe that using a wall suction smoke evacuation system is simple and can result in a more pleasant experience for patients undergoing Mohs surgery.

  14. Comparison of Electrical and Thermal Performances of Glazed and Unglazed PVT Collectors

    Directory of Open Access Journals (Sweden)

    Jin-Hee Kim

    2012-01-01

    Full Text Available Photovoltaic-thermal (PVT collectors combine photovoltaic modules and solar thermal collectors, forming a single device that receives solar radiation and produces electricity and heat simultaneously. PVT collectors can produce more energy per unit surface area than side-by-side PV modules and solar thermal collectors. There are two types of liquid-type flat-plate PVT collectors, depending on the existence of glass cover over PV module: glass-covered (glazed PVT collectors, which produce relatively more thermal energy but have lower electrical yield, and uncovered (unglazed PVT collectors, which have relatively lower thermal energy with somewhat higher electrical performance. In this paper, the experimental performance of two types of liquid-type PVT collectors, glazed and unglazed, was analyzed. The electrical and thermal performances of the PVT collectors were measured in outdoor conditions, and the results were compared. The results show that the thermal efficiency of the glazed PVT collector is higher than that of the unglazed PVT collector, but the unglazed collector had higher electrical efficiency than the glazed collector. The overall energy performance of the collectors was compared by combining the values of the average thermal and electrical efficiency.

  15. Study of 42 and 85 GHz coupled cavity traveling-wave tubes for space use

    Science.gov (United States)

    Kennedy, J. B.; Tammaru, I.; Wolcott, P. S.

    1977-01-01

    Designs were formulated for four CW, millimeter wavelength traveling-wave tubes having high efficiency and long life. Three of these tubes, in the 42 to 44 GHz frequency region, develop power outputs of 100 to 300 watts with overall efficiencies of typically 45 percent. Another tube, which covers the frequency range of 84 to 86 GHz, provides a power output of 200 watts at 25 percent efficiency. The cathode current density in each design was 1A/sq cm. Each tube includes: metal-ceramic construction, periodic permanent magnet focusing, a two step velocity taper, an electron beam refocusing section, and a radiation cooled three-stage depressed collector. The electrical and mechanical design for each tube type is discussed in detail. The results of thermal and mechanical analyses are presented.

  16. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... NEI YouTube Videos > NEI YouTube Videos: Amblyopia NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration ... Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: ...

  17. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... YouTube Videos > NEI YouTube Videos: Amblyopia NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia ... of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: Amblyopia ...

  18. NEI You Tube Videos: Amblyopia

    Science.gov (United States)

    ... YouTube Videos > NEI YouTube Videos: Amblyopia NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia ... of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: Amblyopia ...

  19. Simulation of traffic flow during emergency evacuations: A microcomputer based modeling system

    Energy Technology Data Exchange (ETDEWEB)

    Rathi, A.K.; Solanki, R.S.

    1993-09-01

    Evacuation is one of the major and often preferred protective action options available for emergency management in times of threat to the general public. One of the key factors used in evaluating the effectiveness of evacuation as a protective action option is the estimate of time required for evacuation. The time required for evacuation is the time associated with clearing an area at risk to areas far enough away to be considered safe. Computer simulation models of traffic flow are used to estimate the time it takes to evacuate or ``clear`` an at-risk region by means of vehicular evacuation. This paper provides a brief description of the Oak Ridge Evacuation Modeling System (OREMS), a prototype under development at the Oak Ridge National Laboratory. OREMS consists of a set of computer programs and models which can be used to simulate traffic flow during regional population evacuations and to develop evacuation plans for different events and scenarios (e.g. good vs. bad weather and nighttime vs. daytime evacuations) for user-defined spatial boundaries.

  20. Who evacuates when hurricanes approach? The role of risk, information, and location.

    Science.gov (United States)

    Stein, Robert M; Dueñas-Osorio, Leonardo; Subramanian, Devika

    2010-01-01

    This article offers an expanded perspective on evacuation decision making during severe weather. In particular, this work focuses on uncovering determinants of individual evacuation decisions. We draw on a survey conducted in 2005 of residents in the eight-county Houston metropolitan area after Hurricane Rita made landfall on September 24, 2005. We find that evacuation decisions are influenced by a heterogeneous set of parameters, including perceived risk from wind, influence of media and neighbors, and awareness of evacuation zone, that are often at variance with one of the primary measures of risk used by public officials to order or recommend an evacuation (i.e., storm surge). We further find that perceived risk and its influence on evacuation behavior is a local phenomenon more readily communicated by and among individuals who share the same geography, as is the case with residents living inside and outside official risk areas. Who evacuates and why is partially dependent on where one lives because perceptions of risk are not uniformly shared across the area threatened by an approaching hurricane and the same sources and content of information do not have the same effect on evacuation behavior. Hence, efforts to persuade residential populations about risk and when, where, and how to evacuate or shelter in place should originate in the neighborhood rather than emanating from blanket statements from the media or public officials. Our findings also raise important policy questions (included in the discussion section) that require further study and consideration by those responsible with organizing and implementing evacuation plans.

  1. Rapid health assessments of evacuation centres in areas affected by Typhoon Haiyan

    Directory of Open Access Journals (Sweden)

    Ruth Alma Ramos

    2015-11-01

    Full Text Available Introduction: Typhoon Haiyan caused thousands of deaths and catastrophic destruction, leaving many homeless in Region 8 of the Philippines. A team from the Philippine Field Epidemiology Training Program conducted a rapid health assessment survey of evacuation centres severely affected by Haiyan. Methods: A descriptive study was conducted whereby a convenience sample of evacuation centres were assessed on the number of toilets per evacuee, sanitation, drinking-water, food supply source and medical services. Results: Of the 20 evacuation centres assessed, none had a designated manager. Most were located in schools (70% with the estimated number of evacuees ranging from 15 to 5000 per centre. Only four (20% met the World Health Organization standard for number of toilets per evacuee; none of the large evacuation centres had even half the recommended number of toilets. All of the evacuation centres had available drinking-water. None of the evacuation centres had garbage collection, vector control activities or standby medical teams. Fourteen (70% evacuation centres had onsite vaccination activities for measles, tetanus and polio virus. Many evacuation centres were overcrowded. Conclusion: Evacuation centres are needed in almost every disaster. They should be safely located and equipped with the required amenities. In disaster-prone areas such as the Philippines, schools and community centres should not be designated as evacuation centres unless they are equipped with adequate sanitation services.

  2. Atmospheric Ionic Deposition in Tropical Sites of Central Sulawesi Determined by Ion Exchange Resin Collectors and Bulk Water Collector.

    Science.gov (United States)

    Köhler, S; Jungkunst, H F; Gutzler, C; Herrera, R; Gerold, G

    2012-09-01

    In the light of global change, the necessity to monitor atmospheric depositions that have relevant effects on ecosystems is ever increasing particularly for tropical sites. For this study, atmospheric ionic depositions were measured on tropical Central Sulawesi at remote sites with both a conventional bulk water collector system (BWS collector) and with a passive ion exchange resin collector system (IER collector). The principle of IER collector to fix all ionic depositions, i.e. anions and cations, has certain advantages referring to (1) post-deposition transformation processes, (2) low ionic concentrations and (3) low rainfall and associated particulate inputs, e.g. dust or sand. The ionic concentrations to be measured for BWS collectors may easily fall below detection limits under low deposition conditions which are common for tropical sites of low land use intensity. Additionally, BWS collections are not as independent from the amount of rain fallen as are IER collections. For this study, the significant differences between both collectors found for nearly all measured elements were partly correlated to the rainfall pattern, i.e. for calcium, magnesium, potassium and sodium. However, the significant differences were, in most cases, not highly relevant. More relevant differences between the systems were found for aluminium and nitrate (434-484 %). Almost five times higher values for nitrate clarified the advantage of the IER system particularly for low deposition rate which is one particularity of atmospheric ionic deposition in tropical sites of extensive land use. The monthly resolution of the IER data offers new insights into the temporal distribution of annual ionic depositions. Here, it did not follow the tropical rain pattern of a drier season within generally wet conditions.

  3. Why Don't People Evacuate When Nature Threatens?

    Science.gov (United States)

    Thompson, K. J.; Broad, K.; Meyer, R.; Orlove, B. S.

    2011-12-01

    Why do so many Southern Californians fail to evacuate when warned that winter storms have critically raised the risk of a debris flow in their neighborhoods? Have they perhaps not seen or heeded news coverage of past debris flow events? Are they unaware that recent fires made the hillsides above them more prone to gravity-driven processes? Do they think they can wait to start their cars until they can actually see the flow coming? Or have they merely experienced too many "false alarms" in past years, and no longer put much stock in the judgment of public officials or the ability of scientists to judge debris flow risk? In preparation for a simulation study that will place decision makers in a virtual house in the California foothills during a winter storm event, we explore the reasons that people do and do not evacuate in the face of potential debris flows. Working in collaboration with the USGS Multi-Hazards Demonstration Project for Southern California, we are surveying hundreds of local residents, from debris-flow prone areas and from elsewhere in the state, to establish their baseline knowledge (and misconceptions) about, attitudes toward, information use regarding, and experience with debris flows. Initial interviews with residents of recently hit neighborhoods give qualitative data suggesting that false-alarm effects and underestimation of risk are driving factors; these surveys will provide quantitative evidence to extend those findings. We will discuss the results of this survey in the context of a comprehensive body of psychology research that seeks to explain why people frequently appear to ignore or discount hazard warnings: neglecting to insure their homes and crops (Kunreuther, 1984), failing to evacuate in the face of storms and fires (Baker, 1991; Packham, 1995), and (barring a recent, vivid event) showing little support for measures that would manage or mitigate future hazards (Kunreuther, 2006a, 2006b; Weber, 2006). We will also consider the

  4. Simulation Tool for Optimizing Non-Combatant Evacuation (STONE): Optimization of Evacuation Time and Transportation Resource Utilization

    Science.gov (United States)

    2015-05-01

    Le gouvernement du Canada est responsable de la sécurité et du bien -être de tous les Canadiens. Le MAECD assume cette responsabilité pour les...evacuation centres [16]. It was anticipated that the tool developed would benefit planning requirements for lodging, food, and transportation out of the...handles CEPs who go directly to an EC (on their own) with- out going through an AP. This was not explicitly illustrated in Figure 5 to reduce the

  5. MERCURY CONTROL WITH ADVANCED HYBRID PARTICULATE COLLECTOR

    Energy Technology Data Exchange (ETDEWEB)

    Ye Zhuang; Stanley J. Miller

    2005-05-01

    This project was awarded under U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) Program Solicitation DE-PS26-00NT40769 and specifically addressed Technical Topical Area 4-Testing Novel and Less Mature Control Technologies on Actual Flue Gas at the Pilot Scale. The project team included the Energy & Environmental Research Center (EERC) as the main contractor; W.L. Gore & Associates, Inc., as a technical and financial partner; and the Big Stone Power Plant operated by Otter Tail Power Company, host for the field-testing portion of the research. Since 1995, DOE has supported development of a new concept in particulate control called the advanced hybrid particulate collector (AHPC). The AHPC has been licensed to W.L. Gore & Associates, Inc., and has been marketed as the Advanced Hybrid{trademark} filter by Gore. The Advanced Hybrid{trademark} filter combines the best features of electrostatic precipitators (ESPs) and baghouses in a unique configuration, providing major synergism between the two collection methods, both in the particulate collection step and in the transfer of dust to the hopper. The Advanced Hybrid{trademark} filter provides ultrahigh collection efficiency, overcoming the problem of excessive fine-particle emissions with conventional ESPs, and it solves the problem of reentrainment and re-collection of dust in conventional baghouses. The Advanced Hybrid{trademark} filter also appears to have unique advantages for mercury control over baghouses or ESPs as an excellent gas--solid contactor. The objective of the project was to demonstrate 90% total mercury control in the Advanced Hybrid{trademark} filter at a lower cost than current mercury control estimates. The approach included bench-scale batch tests, larger-scale pilot testing with real flue gas on a coal-fired combustion system, and field demonstration at the 2.5-MW (9000-acfm) scale at a utility power plant to prove scale-up and demonstrate longer-term mercury control

  6. Prototype Tsunami Evacuation Park in Padang, West Sumatra, Indonesia

    Science.gov (United States)

    Tucker, B. E.; Cedillos, V.; Deierlein, G.; Di Mauro, M.; Kornberg, K.

    2012-12-01

    Padang, Indonesia, a city of some 900,000 people, half of whom live close to the coast and within a five-meter elevation above sea level, has one of the highest tsunami risks in the world due to its close offshore thrust-fault seismic hazard, flat terrain and dense population. There is a high probability that a tsunami will strike the shores of Padang, flooding half of the area of the city, within the next 30 years. If that tsunami occurred today, it is estimated that several hundred thousand people would die, as they could not reach safe ground in the ~30 minute interval between the earthquake's occurrence and the tsunami's arrival. Padang's needs have been amply demonstrated: after earthquakes in 2007, 2009, 2011 and 2012, citizens, thinking that those earthquakes might cause a tsunami, tried to evacuate in cars and motorbikes, which created traffic jams, and most could not reach safe ground in 30 minutes. Since 2008, GeoHazards International (GHI) and Stanford University have studied a range of options for improving this situation, including ways to accelerate evacuation to high ground with pedestrian bridges and widened roads, and means of "vertical" evacuation in multi-story buildings, mosques, pedestrian overpasses, and Tsunami Evacuation Parks (TEPs), which are man-made hills with recreation facilities on top. TEPs proved most practical and cost-effective for Padang, given the available budget, technology and time. The Earth Observatory Singapore (EOS) developed an agent-based model that simulates pedestrian and vehicular evacuation to assess tsunami risk and risk reduction interventions in Southeast Asia. EOS applied this model to analyze the effectiveness in Padang of TEPs over other tsunami risk management approaches in terms of evacuation times and the number of people saved. The model shows that only ~24,000 people (20% of the total population) in the northern part of Padang can reach safe ground within 30 minutes, if people evacuate using cars and

  7. Pulse Tube Refrigerator

    Science.gov (United States)

    Matsubara, Yoichi

    The pulse tube refrigerator is one of the regenerative cycle refrigerators such as Stirling cycle or Gifford-McMahon cycle which gives the cooling temperature below 150 K down to liquid helium temperature. In 1963, W. E. Gifford invented a simple refrigeration cycle which is composed of compressor, regenerator and simple tube named as pulse tube which gives a similar function of the expander in Stirling or Gifford-McMahon cycle. The thermodynamically performance of this pulse tube refrigerator is inferior to that of other regenerative cycles. In 1984, however, Mikulin and coworkers made a significant advance in pulse tube configuration called as orifice pulse tube. After this, several modifications of the pulse tube hot end configuration have been developed. With those modifications, the thermodynamic performance of the pulse tube refrigerator became the same order to that of Stirling and Gifford-McMahon refrigerator. This article reviews the brief history of the pulse tube refrigerator development in the view point of its thermodynamically efficiency. Simplified theories of the energy flow in the pulse tube have also been described.

  8. Development of 12.5 m² Solar Collector Panel for Solar Heating Plants

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian; Furbo, Simon; Shah, Louise Jivan

    2004-01-01

    Theoretical and experimental investigations have elucidated how different changes in the design of the 12.5 m(2) HT flat-plate solar collector from the Danish company ARCON Solvarme A/S influence the solar collector efficiency and the yearly thermal performance. The collector is designed for medium...... and large solar heating systems. Based on the theoretical findings a prototype of an improved HT solar collector was built and tested side-by-side with the original HT solar collector. The improved HT collector makes use of a changed insulation material, an absorber with improved absorptance and emittance...

  9. Optimization of solar air collector using genetic algorithm and artificial bee colony algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Sencan Sahin, Arzu [Sueleyman Demirel University, Technology Faculty, Isparta (Turkey)

    2012-11-15

    Thermal performance of solar air collector depends on many parameters as inlet air temperature, air velocity, collector slope and properties related to collector. In this study, the effect of the different parameters which affect the performance of the solar air collector are investigated. In order to maximize the thermal performance of a solar air collector genetic algorithm (GA) and artificial bee colony algorithm (ABC) have been used. The results obtained indicate that GA and ABC algorithms can be applied successfully for the optimization of the thermal performance of solar air collector. (orig.)

  10. A solar collector design procedure for crop drying

    Directory of Open Access Journals (Sweden)

    B. M. Santos

    2005-06-01

    Full Text Available A design procedure was proposed for sizing solar-assisted crop-drying systems and assessing the combination of solar collector area and auxiliary energy needs that meets the requirements of the load. Two empirical correlations were compared for use with high thermal inertia solar collectors that are cheap and appropriate for rural areas. A case study as performed in the city of Campinas in southeastern Brazil. Grain drying with partial air heating by solar energy can provide an annual savings of 30% in fuel consumption for 1.80m² collector area during the drying of 1.2t of corn at 50ºC at a daily air rate of 1526.8 m³/day.

  11. MSFC hot air collectors. Phase 1: Test report

    Science.gov (United States)

    Losey, R.

    1977-01-01

    A development test program of 3 hot air flat plate solar collectors is described in detail. The pressure drop versus flow rate performance characteristics for these collectors, mounted in series, was determined under 14 different test conditions each of which was characterized by a unique combination of inlet air temperature and air flow rate. Characteristics of inlet, exit and transfer ducts of these collectors were also determined during this testing. The test results indicate that significant pressure drop occurs at air flow rates greater than 150 standard cubic feet per minute and this drop is not heavily dependent upon inlet air temperature; and inlet, exit and transfer duct characteristics differ sufficiently to suggest that system performance may be enhanced through careful design of each type of duct individually.

  12. Absorber Alignment Measurement Tool for Solar Parabolic Trough Collectors: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Stynes, J. K.; Ihas, B.

    2012-04-01

    As we pursue efforts to lower the capital and installation costs of parabolic trough solar collectors, it is essential to maintain high optical performance. While there are many optical tools available to measure the reflector slope errors of parabolic trough solar collectors, there are few tools to measure the absorber alignment. A new method is presented here to measure the absorber alignment in two dimensions to within 0.5 cm. The absorber alignment is measured using a digital camera and four photogrammetric targets. Physical contact with the receiver absorber or glass is not necessary. The alignment of the absorber is measured along its full length so that sagging of the absorber can be quantified with this technique. The resulting absorber alignment measurement provides critical information required to accurately determine the intercept factor of a collector.

  13. Categorising YouTube

    DEFF Research Database (Denmark)

    Simonsen, Thomas Mosebo

    2011-01-01

    This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC) of YouTube. The article investigates the construction of navigation processes on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube......’s technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a user-driven bottom-up folksonomy and a hierarchical browsing system that emphasises a culture of competition...... and which favours the already popular content of YouTube. With this taxonomic approach, the UGC videos are registered and analysed in terms of empirically based observations. The article identifies various UGC categories and their principal characteristics. Furthermore, general tendencies of the UGC within...

  14. Long term mental health outcomes of Finnish children evacuated to Swedish families during the second world war and their non-evacuated siblings: cohort study.

    Science.gov (United States)

    Santavirta, Torsten; Santavirta, Nina; Betancourt, Theresa S; Gilman, Stephen E

    2015-01-05

    To compare the risks of admission to hospital for any type of psychiatric disorder and for four specific psychiatric disorders among adults who as children were evacuated to Swedish foster families during the second world war and their non-evacuated siblings, and to evaluate whether these risks differ between the sexes. Cohort study. National child evacuation scheme in Finland during the second world war. Children born in Finland between 1933 and 1944 who were later included in a 10% sample of the 1950 Finnish census ascertained in 1997 (n = 45,463; women: n = 22,021; men: n = 23,442). Evacuees in the sample were identified from war time government records. Adults admitted to hospital for psychiatric disorders recorded between 1971 and 2011 in the Finnish hospital discharge register. We used Cox proportional hazards models to estimate the association between evacuation to temporary foster care in Sweden during the second world war and admission to hospital for a psychiatric disorder between ages 38 and 78 years. Fixed effects methods were employed to control for all unobserved social and genetic characteristics shared among siblings. Among men and women combined, the risk of admission to hospital for a psychiatric disorder did not differ between Finnish adults evacuated to Swedish foster families and their non-evacuated siblings (hazard ratio 0.89, 95% confidence interval 0.64 to 1.26). Evidence suggested a lower risk of admission for any mental disorder (0.67, 0.44 to 1.03) among evacuated men, whereas for women there was no association between evacuation and the overall risk of admission for a psychiatric disorder (1.21, 0.80 to 1.83). When admissions for individual psychiatric disorders were analyzed, evacuated girls were significantly more likely than their non-evacuated sisters to be admitted to hospital for a mood disorder as an adult (2.19, 1.10 to 4.33). The Finnish evacuation policy was not associated with an increased overall risk of admission to hospital

  15. The Group Evacuation Behavior Based on Fire Effect in the Complicated Three-Dimensional Space

    Directory of Open Access Journals (Sweden)

    Jun Hu

    2014-01-01

    Full Text Available In order to effectively depict the group evacuation behavior in the complicated three-dimensional space, a novel pedestrian flow model is proposed with three-dimensional cellular automata. In this model the calculation methods of floor field and fire gain are elaborated at first, and the transition gain of target position at the next moment is defined. Then, in consideration of pedestrian intimacy and velocity change, the group evacuation strategy and evolution rules are given. Finally, the experiments were conducted with the simulation platform to study the relationships of evacuation time, pedestrian density, average system velocity, and smoke spreading velocity. The results had shown that large-scale group evacuation should be avoided, and in case of large pedestrian density, the shortest route of evacuation strategy would extend system evacuation time.

  16. Incorporating emergency evacuation planning, through human reliability analysis, in the risk management of industrial installation

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Isaac J.A. Luquetti; Carvalho, Paulo V.R.; Grecco, Claudio H.S. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)], Email: luquetti@ien.gov.br

    2009-07-01

    An industrial installation presents many risks in the form of the process hazards, such as fire, explosion, gas and radiation release. In these situations, workers may need to evacuate from the work environment as soon as possible. In this case, the emergency evacuation planning is a key element that involves an iterative process to identify the best evacuation routes and to estimate the time required to evacuate the area at risk. The mean aspects for a successful emergency evacuation are influenced by the type of human error and the severity of the initiator event. The aim of this paper is to present a methodological framework for the identification of the performance shaping factors and prediction of human error probabilities of the responsible by the emergency evacuation of the workers in an industrial installation, providing a proactive approach for the allocation of the human factors in the risk assessment of the industrial installation. (author)

  17. The effects of meal size, body size and temperature on gastric evacuation in pikeperch

    DEFF Research Database (Denmark)

    Koed, Anders

    2001-01-01

    Prey size had no effect on the gastric evacuation rate of pikeperch Stizostedion lucioperca. The gastric evacuation was adequately described applying an exponent of 0.5 in the power model. Applying length instead of weight of pikeperch in the gastric evacuation model resulted in a change of estim......Prey size had no effect on the gastric evacuation rate of pikeperch Stizostedion lucioperca. The gastric evacuation was adequately described applying an exponent of 0.5 in the power model. Applying length instead of weight of pikeperch in the gastric evacuation model resulted in a change...... of estimated parameters, in accordance with the weight-length relationship of pikeperch. (C) 2001 The Fisheries Society of the British Isles....

  18. Enhancing Evacuation Plans with a Situation Awareness System Based on End-User Knowledge Provision

    Directory of Open Access Journals (Sweden)

    Augusto Morales

    2014-06-01

    Full Text Available Recent disasters have shown that having clearly defined preventive procedures and decisions is a critical component that minimizes evacuation hazards and ensures a rapid and successful evolution of evacuation plans. In this context, we present our Situation-Aware System for enhancing Evacuation Plans (SASEP system, which allows creating end-user business rules that technically support the specific events, conditions and actions related to evacuation plans. An experimental validation was carried out where 32 people faced a simulated emergency situation, 16 of them using SASEP and the other 16 using a legacy system based on static signs. From the results obtained, we compare both techniques and discuss in which situations SASEP offers a better evacuation route option, confirming that it is highly valuable when there is a threat in the evacuation route. In addition, a study about user satisfaction using both systems is presented showing in which cases the systems are assessed as satisfactory, relevant and not frustrating.

  19. An optimization design for evacuation planning based on fuzzy credibility theory and genetic algorithm

    Science.gov (United States)

    Zhang, D.; Zhang, W. Y.

    2017-08-01

    Evacuation planning is an important activity in disaster management. It has to be planned in advance due to the unpredictable occurrence of disasters. It is necessary that the evacuation plans are as close as possible to the real evacuation work. However, the evacuation plan is extremely challenging because of the inherent uncertainty of the required information. There is a kind of vehicle routing problem based on the public traffic evacuation. In this paper, the demand for each evacuation set point is a fuzzy number, and each routing selection of the point is based on the fuzzy credibility preference index. This paper proposes an approximate optimal solution for this problem by the genetic algorithm based on the fuzzy reliability theory. Finally, the algorithm is applied to an optimization model, and the experiment result shows that the algorithm is effective.

  20. Retrograde Gastrojejunostomy Tube Migration

    Directory of Open Access Journals (Sweden)

    Adeleke Adesina

    2014-01-01

    Full Text Available Percutaneous enteral feeding tubes are placed about 250,000 times each year in the United States. Although they are relatively safe, their placement may be complicated by perforation, infection, bleeding, vomiting, dislodgment, and obstruction. There have been numerous reports of antegrade migration of gastrojejunostomy (G-J tubes. We report a case of G-J tube regurgitation following protracted vomiting and discuss the management of this very rare entity.