WorldWideScience

Sample records for euvl source collector

  1. Experimental and numerical investigations on the density profile of CO2 laser-produced Sn plasma for an EUVL source

    Science.gov (United States)

    Tao, Y.; Ueno, Y.; Yuspeh, S.; Burdt, R. A.; Amin, N.; Shaikh, N. M.; Tillack, M. S.; Najmabadi, F.

    2010-04-01

    Experimentally observed density profile of CO2 laser-produced Sn plasma was compared with that predicted by one dimensional hydrodynamic radiation numerical code. Experimental data showed a much smaller corona and a much shorter shift distance of the critical density from the initial target surface as compared with those predicted by an isothermal model and the numerical simulation. The possible reason may come from thin localized laser deposition region, less energy transport into the corona and into the dense region beyond the critical density. This research suggests that more efforts to understand the fundamental dominating the interaction of CO2 laser with high Z plasma are necessary to form a more solid foundation for the application of numerical method to the development of the EUVL source.

  2. Debris and radiation-induced damage effects on EUV nanolithography source collector mirror optics performance.

    Energy Technology Data Exchange (ETDEWEB)

    Allain, J. P.; Nieto, M.; Hendricks, M.; Harilal, S. S.; Hassanein, A.; Mathematics and Computer Science

    2007-01-01

    Exposure of collector mirrors facing the hot, dense pinch plasma in plasma-based EUV light sources to debris (fast ions, neutrals, off-band radiation, droplets) remains one of the highest critical issues of source component lifetime and commercial feasibility of nanolithography at 13.5-nm. Typical radiators used at 13.5-nm include Xe and Sn. Fast particles emerging from the pinch region of the lamp are known to induce serious damage to nearby collector mirrors. Candidate collector configurations include either multi-layer mirrors (MLM) or single-layer mirrors (SLM) used at grazing incidence. Studies at Argonne have focused on understanding the underlying mechanisms that hinder collector mirror performance at 13.5-nm under fast Sn or Xe exposure. This is possible by a new state-of-the-art in-situ EUV reflectometry system that measures real time relative EUV reflectivity (15-degree incidence and 13.5-nm) variation during fast particle exposure. Intense EUV light and off-band radiation is also known to contribute to mirror damage. For example offband radiation can couple to the mirror and induce heating affecting the mirror's surface properties. In addition, intense EUV light can partially photo-ionize background gas (e.g., Ar or He) used for mitigation in the source device. This can lead to local weakly ionized plasma creating a sheath and accelerating charged gas particles to the mirror surface and inducing sputtering. In this paper we study several aspects of debris and radiation-induced damage to candidate EUVL source collector optics materials. The first study concerns the use of IMD simulations to study the effect of surface roughness on EUV reflectivity. The second studies the effect of fast particles on MLM reflectivity at 13.5-nm. And lastly the third studies the effect of multiple energetic sources with thermal Sn on 13.5-nm reflectivity. These studies focus on conditions that simulate the EUVL source environment in a controlled way.

  3. Debris- and radiation-induced damage effects on EUV nanolithography source collector mirror optics performance

    Science.gov (United States)

    Allain, J. P.; Nieto, M.; Hendricks, M.; Harilal, S. S.; Hassanein, A.

    2007-05-01

    Exposure of collector mirrors facing the hot, dense pinch plasma in plasma-based EUV light sources to debris (fast ions, neutrals, off-band radiation, droplets) remains one of the highest critical issues of source component lifetime and commercial feasibility of nanolithography at 13.5-nm. Typical radiators used at 13.5-nm include Xe and Sn. Fast particles emerging from the pinch region of the lamp are known to induce serious damage to nearby collector mirrors. Candidate collector configurations include either multi-layer mirrors (MLM) or single-layer mirrors (SLM) used at grazing incidence. Studies at Argonne have focused on understanding the underlying mechanisms that hinder collector mirror performance at 13.5-nm under fast Sn or Xe exposure. This is possible by a new state-of-the-art in-situ EUV reflectometry system that measures real time relative EUV reflectivity (15-degree incidence and 13.5-nm) variation during fast particle exposure. Intense EUV light and off-band radiation is also known to contribute to mirror damage. For example offband radiation can couple to the mirror and induce heating affecting the mirror's surface properties. In addition, intense EUV light can partially photo-ionize background gas (e.g., Ar or He) used for mitigation in the source device. This can lead to local weakly ionized plasma creating a sheath and accelerating charged gas particles to the mirror surface and inducing sputtering. In this paper we study several aspects of debris and radiation-induced damage to candidate EUVL source collector optics materials. The first study concerns the use of IMD simulations to study the effect of surface roughness on EUV reflectivity. The second studies the effect of fast particles on MLM reflectivity at 13.5-nm. And lastly the third studies the effect of multiple energetic sources with thermal Sn on 13.5-nm reflectivity. These studies focus on conditions that simulate the EUVL source environment in a controlled way.

  4. SEMATECH EUVL mask program status

    Science.gov (United States)

    Yun, Henry; Goodwin, Frank; Huh, Sungmin; Orvek, Kevin; Cha, Brian; Rastegar, Abbas; Kearney, Patrick

    2009-04-01

    As we approach the 22nm half-pitch (hp) technology node, the industry is rapidly running out of patterning options. Of the several lithography techniques highlighted in the International Technology Roadmap for Semiconductors (ITRS), the leading contender for the 22nm hp insertion is extreme ultraviolet lithography (EUVL). Despite recent advances with EUV resist and improvements in source power, achieving defect free EUV mask blank and enabling the EUV mask infrastructure still remain critical issues. To meet the desired EUV high volume manufacturing (HVM) insertion target date of 2013, these obstacles must be resolved on a timely bases. Many of the EUV mask related challenges remain in the pre-competitive stage and a collaborative industry based consortia, such as SEMATECH can play an important role to enable the EUVL landscape. SEMATECH based in Albany, NY is an international consortium representing several of the largest manufacturers in the semiconductor market. Full members include Intel, Samsung, AMD, IBM, Panasonic, HP, TI, UMC, CNSE (College of Nanoscience and Engineering), and Fuller Road Management. Within the SEMATECH lithography division a major thrust is centered on enabling the EUVL ecosystem from mask development, EUV resist development and addressing EUV manufacturability concerns. An important area of focus for the SEMATECH mask program has been the Mask Blank Development Center (MBDC). At the MBDC key issues in EUV blank development such as defect reduction and inspection capabilities are actively pursued together with research partners, key suppliers and member companies. In addition the mask program continues a successful track record of working with the mask community to manage and fund critical mask tools programs. This paper will highlight recent status of mask projects and longer term strategic direction at the MBDC. It is important that mask technology be ready to support pilot line development HVM by 2013. In several areas progress has been

  5. 100-Picometer Interferometry for EUVL

    Energy Technology Data Exchange (ETDEWEB)

    Sommargren, G E; Phillion, D W; Johnson, M A; Nguyen, N O; Barty, A; Snell, F J; Dillon, D R; Bradsher, L S

    2002-03-18

    Future extreme ultraviolet lithography (EWL) steppers will, in all likelihood, have six-mirror projection cameras. To operate at the diffraction limit over an acceptable depth of focus each aspheric mirror will have to be fabricated with an absolute figure accuracy approaching 100 pm rms. We are currently developing visible light interferometry to meet this need based on modifications of our present phase shifting diffraction interferometry (PSDI) methodology where we achieved an absolute accuracy of 250pm. The basic PSDI approach has been further simplified, using lensless imaging based on computational diffractive back-propagation, to eliminate auxiliary optics that typically limit measurement accuracy. Small remaining error sources, related to geometric positioning, CCD camera pixel spacing and laser wavelength, have been modeled and measured. Using these results we have estimated the total system error for measuring off-axis aspheric EUVL mirrors with this new approach to interferometry.

  6. Photoresists in extreme ultraviolet lithography (EUVL)

    Science.gov (United States)

    De Simone, Danilo; Vesters, Yannick; Vandenberghe, Geert

    2017-06-01

    The evolutionary advances in photosensitive material technology, together with the shortening of the exposure wavelength in the photolithography process, have enabled and driven the transistor scaling dictated by Moore's law for the last 50 years. Today, the shortening wavelength trend continues to improve the chips' performance over time by feature size miniaturization. The next-generation lithography technology for high-volume manufacturing (HVM) is extreme ultraviolet lithography (EUVL), using a light source with a wavelength of 13.5 nm. Here, we provide a brief introduction to EUVL and patterning requirements for sub-0-nm feature sizes from a photomaterial standpoint, discussing traditional and novel photoresists. Emphasis will be put on the novel class of metal-containing resists (MCRs) as well as their challenges from a manufacturing prospective.

  7. Properites of ultrathin films appropriate for optics capping layers in extreme ultraviolet lithography (EUVL)

    Energy Technology Data Exchange (ETDEWEB)

    Bajt, S; Edwards, N V; Madey, T E

    2007-06-25

    The contamination of optical surfaces by irradiation shortens optics lifetime and is one of the main concerns for optics used in conjunction with intense light sources, such as high power lasers, 3rd and 4th generation synchrotron sources or plasma sources used in extreme ultraviolet lithography (EUVL) tools. This paper focuses on properties and surface chemistry of different materials, which as thin layers, could be used as capping layers to protect and extend EUVL optics lifetime. The most promising candidates include single element materials such as ruthenium and rhodium, and oxides such as TiO{sub 2} and ZrO{sub 2}.

  8. Optics and multilayer coatings for EUVL systems

    Energy Technology Data Exchange (ETDEWEB)

    Soufli, R; Bajt, S; Hudyma, R M; Taylor, J S

    2008-03-21

    EUV lithography (EUVL) employs illumination wavelengths around 13.5 nm, and in many aspects it is considered an extension of optical lithography, which is used for the high-volume manufacturing (HVM) of today's microprocessors. The EUV wavelength of illumination dictates the use of reflective optical elements (mirrors) as opposed to the refractive lenses used in conventional lithographic systems. Thus, EUVL tools are based on all-reflective concepts: they use multilayer (ML) coated optics for their illumination and projection systems, and they have a ML-coated reflective mask.

  9. Challenges and solutions ensuring EUVL photomask integrity

    Science.gov (United States)

    Brux, O.; Dreß, P.; Schmalfuß, H.; Jonckheere, R.; Koolen-Hermkens, W.

    2012-06-01

    Industry roadmaps indicate that the introduction of Extreme Ultraviolet Lithography (EUVL) is on track for high volume manufacturing. Although, there has been significant progress in each of the individual subsets of the EUVL infrastructure, the absolute management of the process outside of the scanner and up to the point-of-exposure has been highlighted as critical requirement for the adoption of EUVL. Significant changes in the EUV system environment and mask architecture are driving a zero process tolerance level. Any unforeseen contamination introduced to the scanner environment from the EUV mask could cause considerable downtime and yield loss. Absolute mask integrity at the point-of-exposure must be guaranteed. EUV mask cleaning processes-of-record have been developed and introduced to the industry [1]. The issue is not longer "how to clean the mask" but, "how to keep it clean". With the introduction of EUVL, mask cleanliness extends out beyond the traditional mask cleaning tool. Complete control of contamination and/or particles during transportation, handling and storage will require a holistic approach to mask management. A new environment specifically for EUV mask integrity must be developed and fully tested for the sub 16nm half-pitch node introduction. The SUSS MaskTrack Pro (MTP) InSync was introduced as the solution for EUV mask integrity. SUSS demonstrated the fully automated handling of EUV masks into and out of a Dual Pod System [2]. Intrinsic cleanliness of each individual handling and storage step of the inner pod (EIP) and EUV mask inside the MTP InSync Tool was investigated and reported. A target specification of a PRP <= 0.08 as criterion for the cross contamination between EIP and the EUV reticle during handling within MTP InSync has been achieved and therefore proofing the applicability for the Dual Pod automation. Moreover an appropriate automated handling, other aspects like backside particle contamination and EIP cleanliness plays a

  10. Deposition and sputtering yields on EUV collector mirror from Laser Plasma Extreme Ultraviolet Sources

    Energy Technology Data Exchange (ETDEWEB)

    Wu Tao [Wuhan National Laboratory for Optoelectronics, School of Optoelectronic Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Rao Zhiming [Depart of Computer Science, Jiangxi University of Traditional Chinese Medicine, Nanchang 330004, Jiangxi (China); Wang Shifang, E-mail: flatime@163.com [School of Physics and Electric Information, Hubei University of Education 1 Nanhuan Road, Wuhan East High-Tech. Zone, Wuhan 430205, Hubei (China)

    2011-02-01

    Based on the self-similar solution of gas dynamic equations, spherical expansion of the highly ionized plasma with limited mass into a vacuum is investigated for the droplet target laser-produced plasma extreme ultraviolet (LPP-EUV) sources. Using partially numerical and partially analytical technology, the velocity, the temperature and the density profiles in the plume versus ionization degree, adiabatic index and initial conditions are presented. Furthermore, the spatial thickness variations of the deposited substrate witness and ion sputtering yields for Ru, Mo, and Si under Sn ion bombardment are theoretically calculated, which can be useful to enable LPP-EUV sources suppliers to estimate collector lifetime and improve debris mitigation systems.

  11. Molecular contamination mitigation in EUVL by environmental control

    NARCIS (Netherlands)

    Koster, N.; Mertens, B.; Jansen, R.; van de Runstraat, A.; Stietz, F.; Wedowski, M.; Meiling, H.; Klein, R.; Gottwald, A.; Scholze, F.; Visser, M.; Kurt, R.; Zalm, P.; E. Louis,; Yakshin, A.

    2002-01-01

    EUVL tools operate under vacuum conditions to avoid absorption losses. Under these conditions, the MoSi multilayer mirrors are contaminated, resulting in reduced reflection and thus throughput. We report on experiments on MoSi mirrors exposed to EUV radiation from a synchrotron. To mimic the effects

  12. Genesis Solar Wind Science Canister Components Curated as Potential Solar Wind Collectors and Reference Contamination Sources

    Science.gov (United States)

    Allton, J. H.; Gonzalez, C. P.; Allums, K. K.

    2016-01-01

    The Genesis mission collected solar wind for 27 months at Earth-Sun L1 on both passive and active collectors carried inside of a Science Canister, which was cleaned and assembled in an ISO Class 4 cleanroom prior to launch. The primary passive collectors, 271 individual hexagons and 30 half-hexagons of semiconductor materials, are described in. Since the hard landing reduced the 301 passive collectors to many thousand smaller fragments, characterization and posting in the online catalog remains a work in progress, with about 19% of the total area characterized to date. Other passive collectors, surfaces of opportunity, have been added to the online catalog. For species needing to be concentrated for precise measurement (e.g. oxygen and nitrogen isotopes) an energy-independent parabolic ion mirror focused ions onto a 6.2 cm diameter target. The target materials, as recovered after landing, are described in. The online catalog of these solar wind collectors, a work in progress, can be found at: http://curator.jsc.nasa.gov/gencatalog/index.cfm This paper describes the next step, the cataloging of pieces of the Science Canister, which were surfaces exposed to the solar wind or component materials adjacent to solar wind collectors which may have contributed contamination.

  13. Detectability and printability of EUVL mask blank defects for the 32-nm HP node

    Science.gov (United States)

    Cho, Wonil; Han, Hak-Seung; Goldberg, Kenneth A.; Kearney, Patrick A.; Jeon, Chan-Uk

    2007-10-01

    The readiness of a defect-free extreme ultraviolet lithography (EUVL) mask blank infrastructure is one of the main enablers for the insertion of EUVL technology into production. It is essential to have sufficient defect detection capability and understanding of defect printability to develop a defect-free EUVL mask blank infrastructure. The SEMATECH Mask Blank Development Center (MBDC) has been developing EUVL mask blanks with low defect densities with the Lasertec M1350 and M7360, the 1st and 2nd generations, respectively, of visible light EUVL mask blank inspection tools. Although the M7360 represents a significant improvement in our defect detection capability, it is time to start developing a 3rd generation tool for EUVL mask blank inspection. The goal of this tool is to detect all printable defects; therefore, understanding defect printability criteria is critical to this tool development. In this paper, we will investigate the defect detectability of a 2nd generation blank inspection tool and a patterned EUVL mask inspection tool. We will also compare the ability of the inspection tools to detect programmed defects whose printability has been estimated from wafer printing results and actinic aerial images results.

  14. Testing of PCM Heat Storage Modules with Solar Collectors as Heat Source

    DEFF Research Database (Denmark)

    Englmair, Gerald; Dannemand, Mark; Johansen, Jakob Berg

    2016-01-01

    was to actively utilize the ability of the material to supercool to obtain long storage periods. The modules were charged with solar heat supplied by 22.4 m2 evacuated tubular collectors. The investigation showed that it was possible to fully charge one module within a period of 270 minutes with clear skies......A latent heat storage based on the phase change material Sodium Acetate Trihydrate (SAT) has been tested as part of a demonstration system. The full heat storage consisted of 4 individual modules each containing about 200 kg of sodium acetate trihydrate with different additives. The aim...

  15. Solar Collectors

    Science.gov (United States)

    1980-01-01

    Solar Energy's solar panels are collectors for a solar energy system which provides heating for a drive-in bank in Akron, OH. Collectors were designed and manufactured by Solar Energy Products, a firm established by three former NASA employees. Company President, Frank Rom, an example of a personnel-type technology transfer, was a Research Director at Lewis Research Center, which conducts extensive solar heating and cooling research, including development and testing of high-efficiency flat-plate collectors. Rom acquired solar energy expertise which helped the company develop two types of collectors, one for use in domestic/commercial heating systems and the other for drying grain.

  16. Stardust Interstellar Preliminary Examination II: Curating the Interstellar Dust Collector, Picokeystones, and Sources of Impact Tracks

    Science.gov (United States)

    Frank, David R.; Westphal, Andrew J.; Zolensky, Michael E.; Gainsforth, Zack; Butterworth, Anna L.; Bastien, Ronald K.; Allen, Carlton; Anderson, David; Bechtel, Hans A.; Sandford, Scott A.

    2013-01-01

    We discuss the inherent difficulties that arise during "ground truth" characterization of the Stardust interstellar dust collector. The challenge of identifying contemporary interstellar dust impact tracks in aerogel is described within the context of background spacecraft secondaries and possible interplanetary dust particles and beta-meteoroids. In addition, the extraction of microscopic dust embedded in aerogel is technically challenging. Specifically, we provide a detailed description of the sample preparation techniques developed to address the unique goals and restrictions of the Interstellar Preliminary Exam. These sample preparation requirements and the scarcity of candidate interstellar impact tracks exacerbate the difficulties. We also illustrate the role of initial optical imaging with critically important examples, and summarize the overall processing of the collection to date.

  17. Source term boundary adaptive estimation in a first-order 1D hyperbolic PDE: Application to a one loop solar collector through

    KAUST Repository

    Mechhoud, Sarra

    2016-08-04

    In this paper, boundary adaptive estimation of solar radiation in a solar collector plant is investigated. The solar collector is described by a 1D first-order hyperbolic partial differential equation where the solar radiation models the source term and only boundary measurements are available. Using boundary injection, the estimator is developed in the Lyapunov approach and consists of a combination of a state observer and a parameter adaptation law which guarantee the asymptotic convergence of the state and parameter estimation errors. Simulation results are provided to illustrate the performance of the proposed identifier.

  18. Solar collector

    Science.gov (United States)

    Wilhelm, William G.

    1982-01-01

    The field of this invention is solar collectors, and more particularly, the invention pertains to a flat plate collector that employs high performance thin films. The solar collector of this invention overcomes several problems in this field, such as excessive hardware, cost and reliability, and other prior art drawbacks outlined in the specification. In the preferred form, the apparatus features a substantially rigid planar frame (14). A thin film window (42) is bonded to one planar side of the frame. An absorber (24) of laminate construction is comprised of two thin film layers (24a, 24b) that are sealed perimetrically. The layers (24a, 24b) define a fluid-tight planar envelope (24c) of large surface area to volume through which a heat transfer fluid flows. Absorber (24) is bonded to the other planar side of the frame. The thin film construction of the absorber assures substantially full envelope wetting and thus good efficiency. The window and absorber films stress the frame adding to the overall strength of the collector.

  19. Imaging collector channel entrance with a new intraocular micro-probe swept-source optical coherence tomography.

    Science.gov (United States)

    Xin, Chen; Chen, Xiaoya; Li, Meng; Shi, Yan; Wang, Huaizhou; Wang, Ruikang; Wang, Ningli

    2017-09-01

    To describe the use of a newly developed side-viewing catheter probe to provide the cross-sectional images of collector channel entrance (CCE), achieved by swept-source optical coherence tomography (SS-OCT). A side-viewing SS-OCT catheter probe was developed that has a core probe diameter of 0.15 mm and an outer diameter of 0.25 mm, for the purpose of imaging CCEs within eye globe. Cadaver eyes harvested from swine and human were used to demonstrate its feasibility. For porcine eyes, the probe imaged the CCE by accessing the region of the aqueous plexus (AP) as well as along the inner wall (IW) of the trabecular meshwork (TM). For human eyes, the CCE images were captured by placing the probe within the lumen of the Schlemm's canal (SC) and along its IW. With the optical coherence tomography (OCT) catheter probe, the CCE is well delineated as optically empty areas within the highly scattering sclera. In porcine eyes, images captured in the region of the AP demonstrate a large cavity with delicate tissue strands around the probe. The CCE can be identified at the outer margin of the AP. When imaged along the IW, the TM is discernable but difficult to be distinguished from the AP. In the human limbal regions, when placed within the lumen of the SC, the catheter probe fully occupies the potential space. TM is highly compact. The CCE can be identified at the outer wall of the SC. When imaged along the IW of TM, the SC and CCE can be identified. The intraocular SS-OCT catheter probe is feasible to provide the CCE images, indicating useful clinical applications to assist glaucoma surgery. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. High-performance next-generation EUV lithography light source

    Science.gov (United States)

    Choi, Peter; Zakharov, Sergey V.; Aliaga-Rossel, Raul; Benali, Otman; Duffy, Grainne; Sarroukh, Ouassima; Wyndham, Edmund; Zakharov, Vasily S.

    2009-03-01

    EUVL solution for HVM at the 22 nm node requires a high power long-term EUV source operation with hundreds of watts at the intermediate focus output. EUV mask blank and mask defects inspections require at-wavelength tools with high brightness. Theoretical analysis with a 2-D radiation MHD code Z* has been performed to address key issues in EUV plasma sources with radiation transfer. The study shows that self-absorption defines the limiting brightness of a single EUV source, which cannot meet the requirements of the HVM tool with high efficiency and is not sufficient for critical metrology applications, given the limiting etendue of the optics. It is shown that the required irradiance can be achieved by spatial multiplexing, using multiple small sources. We present here details of the study, as well as experimental results from a novel EUV light source with an intrinsic photon collector demonstrating high brightness, the i-SoCoMo concept, where an impulse micro discharge plasma source is integrated to a photon collector based on an active plasma structure. The small physical size and low etendue properties of the i-SoCoMo unit allows a large number of such sources to be put together in one physical package and be operated in a multiplexed fashion to meet necessary power requirements.

  1. Actinic defect counting statistics over 1 cm2 area of EUVL mask blank

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Seongtae; Lai, Chih-Wei; Rekawa, Seno; Walton, Chris W.; Bokor, Jeffrey

    2000-02-18

    As a continuation of comparison experiments between EUV inspection and visible inspection of defects on EUVL mask blanks, we report on the result of an experiment where the EUV defect inspection tool is used to perform at-wavelength defect counting over 1 cm{sup 2} of EUVL mask blank. Initial EUV inspection found five defects over the scanned area and the subsequent optical scattering inspection was able to detect all of the five defects. Therefore, if there are any defects that are only detectable by EUV inspection, the density is lower than the order of unity per cm2. An upgrade path to substantially increase the overall throughput of the EUV inspection system is also identified in the manuscript.

  2. Simple, economical solar collector

    Science.gov (United States)

    Anthony, K.

    1979-01-01

    Hot air solar collector designed for economy and simplicity is assembled from only three parts: (1) molded urethane foam body, (2) flat sheet metal collector panel and (3) transparent cover. Large arrays may be assembled by inserting male fittings of each collector into female fitting of adjacent collector.

  3. Connectable solar air collectors

    Energy Technology Data Exchange (ETDEWEB)

    Oestergaard Jensen, S.; Bosanac, M.

    2002-02-01

    The project has proved that it is possible to manufacture solar air collector panels, which in an easy way can be connected into large collector arrays with integrated ducting without loss of efficiency. The developed connectable solar air collectors are based on the use of matrix absorbers in the form of perforated metal sheets. Three interconnected solar air collectors of the above type - each with an transparent area of approx. 3 m{sup 2} - was tested and compared with parallel tests on two single solar air collectors also with a transparent area of approx. 3 m{sup 2} One of the single solar air collectors has an identical absorber as the connectable solar air collectors while the absorber of the other single solar air collector was a fibre cloth. The efficiency of the three solar air collectors proved to be almost identical in the investigated range of mass flow rates and temperature differences. The solar air collectors further proved to be very efficient - as efficient as the second most efficient solar air collectors tested in the IEA task 19 project Solar Air Systems. Some problems remain although to be solved: the pressure drop across especially the connectable solar air collectors is too high - mainly across the inlets of the solar air collectors. It should, however, be possible to considerably reduce the pressure losses with a more aerodynamic design of the inlet and outlet of the solar air collectors; The connectable solar air collectors are easy connectable but the air tightness of the connections in the present form is not good enough. As leakage leads to lower efficiencies focus should be put on making the connections more air tight without loosing the easiness in connecting the solar air collectors. As a spin off of the project a simple and easy way to determine the efficiency of solar, air collectors for pre-heating of fresh air has been validated. The simple method of determining the efficiency has with success been compared with an advance method

  4. Air/liquid collectors

    DEFF Research Database (Denmark)

    Jensen, Søren Østergaard; Olesen, Ole; Kristiansen, Finn Harken

    1997-01-01

    this kind of collectors. The modified simulation program has been used for the determination of the surplus in performance which solar heating systems with this type of solar collectors for combined preheating of ventilation air and domestic hot water will have. The simulation program and the efficiency......This report determine efficiency equations for combined air/liquid solar collectors by measurements on to different air/liquid collectors. Equations which contain all relevant informations on the solar collectors. A simulation program (Kviksol) has been modified in order to be able to handle...

  5. Status of EUVL mask development in Europe (Invited Paper)

    Science.gov (United States)

    Peters, Jan H.

    2005-06-01

    EUV lithography is the prime candidate for the next generation lithography technology after 193 nm immersion lithography. The commercial onset for this technology is expected for the 45 nm half-pitch technology or below. Several European and national projects and quite a large number of companies and research institutions in Europe work on various aspects of the technological challenges to make EUV a commercially viable technology in the not so far future. Here the development of EUV sources, the development of an EUV exposure tools, metrology tools dedicated for characterization of mask, the production of EUV mask blanks and the mask structuring itself are the key areas in which major activities can be found. In this talk we will primarily focus on those activities, which are related to establish an EUV mask supply chain with all its ingredients from substrate production, polishing, deposition of EUV layers, blank characterization, mask patterning process and the consecutive metrology and defect inspection as well as shipping and handling from blank supply to usage in the wafer fab. The EUV mask related projects on the national level are primarily supported by the French Ministry of Economics and Finance (MinEFi) and the German Ministry of Education and Research (BMBF).

  6. Selecting baghouse dust collectors

    Energy Technology Data Exchange (ETDEWEB)

    Moore, S.; Rubak, J.; Jolin, M. [Farr Co., El Segundo, CA (United States)]|[Farr Co., Laval, Quebec (Canada)

    1997-04-01

    A thorough analysis of the dust to be captured and determination of specific application requirements are necessary when designing a baghouse collection system. Independent consultants specializing in pollution control equipment and manufacturers with experience in several types of collectors are possible sources of assistance. These experts typically have testing facilities to analyze the dust characteristics. This final article of a two-part series on baghouse design and selection concentrates on application considerations created by the type of dust handled, selecting the best filtration media, selecting the best filtration media, and determining the air-to-cloth (A/C) ratio. The first article discussed bag sizing and cleaning methods and housing and hopper designs.

  7. Pulsed depressed collector

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, Mark A

    2015-11-03

    A high power RF device has an electron beam cavity, a modulator, and a circuit for feed-forward energy recovery from a multi-stage depressed collector to the modulator. The electron beam cavity include a cathode, an anode, and the multi-stage depressed collector, and the modulator is configured to provide pulses to the cathode. Voltages of the electrode stages of the multi-stage depressed collector are allowed to float as determined by fixed impedances seen by the electrode stages. The energy recovery circuit includes a storage capacitor that dynamically biases potentials of the electrode stages of the multi-stage depressed collector and provides recovered energy from the electrode stages of the multi-stage depressed collector to the modulator. The circuit may also include a step-down transformer, where the electrode stages of the multi-stage depressed collector are electrically connected to separate taps on the step-down transformer.

  8. Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings

    DEFF Research Database (Denmark)

    Kjellsson, Elisabeth; Hellström, Göran; Perers, Bengt

    2010-01-01

    -source heat pumps, computer simulations have been carried out with the simulation program TRNSYS. Large differences were found between the system alternatives. The optimal design is when solar heat produces domestic hot water during summertime and recharges the borehole during wintertime. The advantage...... is related to the rate of heat extraction from the borehole as well as the overall design of the system. The demand of electricity may increase with solar recharging, because of the increased operating time of the circulation pumps. Another advantage with solar heat in combination with heat pumps is when...... by recharge from solar heat....

  9. A particle-in-cell plus Monte Carlo study of plasma-induced damage of normal incidence collector optics used in extreme ultraviolet lithography

    NARCIS (Netherlands)

    Wieggers, R. C.; W. J. Goedheer,; M.R. Akdim,; F. Bijkerk,; Zegeling, P. A.

    2008-01-01

    We present a kinetic simulation of the plasma formed by photoionization in the intense flux of an extreme ultraviolet lithography (EUVL) light source. The model is based on the particle-in-cell plus Monte Carlo approach. The photoelectric effect and ionization by electron collisions are included.

  10. Effective EUVL mask cleaning technology solutions for mask manufacturing and in-fab mask maintenance

    Science.gov (United States)

    Dietze, Uwe; Dress, Peter; Waehler, Tobias; Singh, Sherjang; Jonckheere, Rik; Baudemprez, Bart

    2011-03-01

    Extreme Ultraviolet Lithography (EUVL) is considered the leading lithography technology choice for semiconductor devices at 16nm HP node and beyond. However, before EUV Lithography can enter into High Volume Manufacturing (HVM) of advanced semiconductor devices, the ability to guarantee mask integrity at point-of-exposure must be established. Highly efficient, damage free mask cleaning plays a critical role during the mask manufacturing cycle and throughout the life of the mask, where the absence of a pellicle to protect the EUV mask increases the risk of contamination during storage, handling and use. In this paper, we will present effective EUVL mask cleaning technology solutions for mask manufacturing and in-fab mask maintenance, which employs an intelligent, holistic approach to maximize Mean Time Between Cleans (MBTC) and extend the useful life span of the reticle. The data presented will demonstrate the protection of the capping and absorber layers, preservation of pattern integrity as well as optical and mechanical properties to avoid unpredictable CD-linewidth and overlay shifts. Experiments were performed on EUV blanks and pattern masks using various process conditions. Conditions showing high particle removal efficiency (PRE) and minimum surface layer impact were then selected for durability studies. Surface layer impact was evaluated over multiple cleaning cycles by means of UV reflectivity metrology XPS analysis and wafer prints. Experimental results were compared to computational models. Mask life time predictions where made using the same computational models. The paper will provide a generic overview of the cleaning sequence which yielded best results, but will also provide recommendations for an efficient in-fab mask maintenance scheme, addressing handling, storage, cleaning and inspection.

  11. All-glass solar collector

    Science.gov (United States)

    Wisnewski, J. P.

    1980-01-01

    Proposed all tempered glass solar collector uses black collection fluid and mirrored bottom to reduce energy loss and overall costs associated with conventional collectors. Collector is more efficient and practically maintenance-free.

  12. Solar collector overheating protection

    NARCIS (Netherlands)

    Slaman, M.J.; Griessen, R.P.

    Prismatic structures in a thermal solar collector are used as overheating protection. Such structures reflect incoming light efficiently back whenever less thermal power is extracted from the solar collector. Maximum thermal power is generated when the prismatic structure is surrounded by a

  13. Comparative Study on Solar Collector's Configuration for an Ejector-Refrigeration Cycle

    OpenAIRE

    Senjaya, Raffles; Astina, I Made

    2008-01-01

    Solar collector's configuration plays important role on solar-powered refrigeration systems to work as heat source for generator . Three types of solar collector consisting of flat plate, evacuated tube, and compound parabolic solar collectors are compared to investigate their performances. The performances consist of the behavior of heat which can be absorbed by the collectors, heat loss from the collectors and outlet temperature of working fluid at several slopes of the solar...

  14. Modeling EUVL patterning variability for metal layers in 5nm technology node and its effect on electrical resistance

    Science.gov (United States)

    Gao, Weimin; Blanco, Victor; Philipsen, Vicky; Kamohara, Itaru; Saad, Yves; Ciofi, Ivan; Melvin, Lawrence S.; Hendrickx, Eric; Wiaux, Vincent; Kim, Ryoung Han

    2017-03-01

    In 5nm node, even minor process variation in extreme ultraviolet lithography (EUVL) can bring significant impact to the device performance. Except for the overlay and critical dimension uniformity (CDU), EUV specific effects, such as shadowing, three-dimensional mask effect (M3D), and stochastic effects, must also be understood in processing, modeling, and optical proximity correction (OPC). We simulate those variabilities using a calibrated model and compare it to what is observed on the wafer. The interconnect path of Metal1-Via1-Metal2 is studied by using a silicon-calibrated resistivity model to analyze the related overlap area and the electrical resistance. The approach allows us to quantify the impact of EUVL process by investigating the individual contribution of each patterning process variations.

  15. Internal absorber solar collector

    Science.gov (United States)

    Sletten, Carlyle J.; Herskovitz, Sheldon B.; Holt, F. S.; Sletten, E. J.

    1981-01-01

    Thin solar collecting panels are described made from arrays of small rod collectors consisting of a refracting dielectric rod lens with an absorber imbedded within it and a reflecting mirror coated on the back side of the dielectric rod. Non-tracking collector panels on vertical walls or roof tops receive approximately 90% of solar radiation within an acceptance zone 60.degree. in elevation angle by 120.degree. or more in the azimuth sectors with a collector concentration ratio of approximately 3.0. Miniaturized construction of the circular dielectric rods with internal absorbers reduces the weight per area of glass, plastic and metal used in the collector panels. No external parts or insulation are needed as heat losses are low due to partial vacuum or low conductivity gas surrounding heated portions of the collector. The miniature internal absorbers are generally made of solid copper with black selective surface and the collected solar heat is extracted at the collector ends by thermal conductivity along the absorber rods. Heat is removed from end fittings by use of liquid circulants. Several alternate constructions are provided for simplifying collector panel fabrication and for preventing the thermal expansion and contraction of the heated absorber or circulant tubes from damaging vacuum seals. In a modified version of the internal absorber collector, oil with temperature dependent viscosity is pumped through a segmented absorber which is now composed of closely spaced insulated metal tubes. In this way the circulant is automatically diverted through heated portions of the absorber giving higher collector concentration ratios than theoretically possible for an unsegmented absorber.

  16. Predation of shore crabs (Carcinus maenas (L.)) and starfish (Asterias rubens L.) on blue mussel (Mytilus edulis L.) seed from wild sources and spat collectors

    NARCIS (Netherlands)

    Kamermans, P.; Blankendaal, M.; Perdon, J.

    2009-01-01

    In The Netherlands, several pilot projects are carried out on the use of spat collectors as an additional supply of seed for bottom culture of mussels (Mytilus edulis). The method proves to be successful in yielding substantial amounts of seed. One of the conditions for successful application of

  17. Predation of shore crabs (Carcinus maenas (L)) and starfish (Asterias rubens L.) on blue mussel (Mytilus edulis L.) seed from wild sources and spat collectors

    NARCIS (Netherlands)

    Kamermans, P.; Blankendaal, M.; Perdon, K.J.

    2009-01-01

    In The Netherlands, several pilot projects are carried out on the use of spat collectors as an additional supply of seed for bottom culture of mussels (Mytilus edulis). The method proves to be successful in yielding substantial amounts of seed. One of the conditions for successful application of

  18. Dual axis solar collector assembly

    Energy Technology Data Exchange (ETDEWEB)

    Eiden, G.E.

    1991-02-19

    This patent describes a solar collector. It comprises: an elongate main boom having a longitudinal axis; a solar collector frame first mounting means for pivotally mounting the solar collector frame to the main boom for pivotal motion about first pivotal axis substantially parallel to the longitudinal axis of the main boom; and first motor means, separate from the first mounting means a generally horizontal countertop mounted on the frame means adapted for a placement and retention of an ostomy bag thereon during cleaning of the ostomy bag. The countertop having a sink formed therein for draining liquid and waste materials from the ostomy bag and from the countertop; a mirror mounted upright on the frame means; a light source mounted to the frame means for illuminating the countertop, a user and the mirror; and a drainage conduit, having a first end connected to the sink, the drainage conduit being adapted for carrying the waste materials and the liquid from the sink to the disposal location.

  19. High-volume manufacturing compatible dry development rinse process (DDRP): patterning and defectivity performance for EUVL

    Science.gov (United States)

    Sayan, Safak; Vanelderen, Pieter; Hetel, Iulian; Chan, BT; Raghavan, Praveen; Blanco, Victor; Foubert, Philippe; D'urzo, Lucia; De Simone, Danilo; Vandenberghe, Geert

    2017-04-01

    There are many knobs available that change the chemical and physical properties of the photoresists to "break" the RLS (Resolution, Sensitivity, Line edge/width roughness) trade-off, however those are not enough today to realize a material to satisfy all requirements at once for 7nm technology and beyond. DDRP improves the ultimate achievable resolution via pattern collapse mitigation, hence the priority of requirements for the EUV photoresist development may be changed with more focus on Sensitivity and LWR. This may potentially provide a new conceptual approach towards EUV PR development for DDRP applications. We have previously demonstrated pattern collapse (PC) mitigation via DDRP on different EUVL photoresists (including different resist platforms), achieving ultimate resolution and exposure latitude improvements [1,2]. In this contribution, we report patterning and material defect performance of HVM compatible (all aqueous) dry development rinse material. We will also report on process window improvement on 2-dimensional metal structures towards standard cell size reduction with elimination of mask layer(s) using single EUV exposure.

  20. NEG (non evaporable getter) pumps for organic compounds and water removal in EUVL tools

    Science.gov (United States)

    Conte, A.; Manini, P.; Raimondi, S.

    2008-03-01

    One of present EUVL challenges is to reduce as much as possible the organic compounds and water partial pressures during the lithographic process. These gases can in fact interact with sensitive surfaces and, in the presence of EUV radiation, decompose to generate carbon-based films and oxides, which are detrimental to the optics, reducing its performance, lifetime and significantly increasing the equipment total cost of ownership. With this respect, use of Non Evaporable Getter (NEG) pumps seems particularly attractive. Getter pumps are very clean, vibration-free, compact, able to deliver large pumping speed for all active gases, including water and hydrogen. In the present paper, we report for the first time the results of specific tests aimed at measuring the pumping speed for some selected organic compounds, namely toluene and decane (n-decane). The study shows that getter pumps can effectively sorb these large organic molecules with high speed and capacity. Speed and capacity increases when operating the getter cartridge at moderate temperature (e.g. 150-200°C), however remarkable sorption is achieved, even at room temperature, without any power applied. When coupled with turbo-molecular pumps NEG pumps have therefore the potential to improve the ultimate vacuum and mitigate the carbon/oxygen contamination in a UHV lithographic system.

  1. Tracking system for solar collectors

    Science.gov (United States)

    Butler, B.

    1980-10-01

    A tracking system is provided for pivotally mounted spaced-apart solar collectors. A pair of cables is connected to spaced-apart portions of each collector, and a driver displaces the cables, thereby causing the collectors to pivot about their mounting, so as to assume the desired orientation. The collectors may be of the cylindrical type as well as the flat-plate type. Rigid spar-like linkages may be substituted for the cables. Releasable attachments of the cables to the collectors is also described, as is a fine tuning mechanism for precisely aligning each individual collector.

  2. Tracking system for solar collectors

    Science.gov (United States)

    Butler, Barry L.

    1984-01-01

    A tracking system is provided for pivotally mounted spaced-apart solar collectors. A pair of cables is connected to spaced-apart portions of each collector, and a driver displaces the cables, thereby causing the collectors to pivot about their mounting, so as to assume the desired orientation. The collectors may be of the cylindrical type as well as the flat-plate type. Rigid spar-like linkages may be substituted for the cables. Releasable attachments of the cables to the collectors is also described, as is a fine tuning mechanism for precisely aligning each individual collector.

  3. Biological sample collector

    Science.gov (United States)

    Murphy, Gloria A [French Camp, CA

    2010-09-07

    A biological sample collector is adapted to a collect several biological samples in a plurality of filter wells. A biological sample collector may comprise a manifold plate for mounting a filter plate thereon, the filter plate having a plurality of filter wells therein; a hollow slider for engaging and positioning a tube that slides therethrough; and a slide case within which the hollow slider travels to allow the tube to be aligned with a selected filter well of the plurality of filter wells, wherein when the tube is aligned with the selected filter well, the tube is pushed through the hollow slider and into the selected filter well to sealingly engage the selected filter well and to allow the tube to deposit a biological sample onto a filter in the bottom of the selected filter well. The biological sample collector may be portable.

  4. Development of the negative-tone molecular resists for EB/EUVL having high EUV absorption capacity and molecular design method

    Science.gov (United States)

    Sato, Takashi; Takigawa, Tomoaki; Togashi, Yuta; Toida, Takumi; Echigo, Masatoshi; Harada, Tetsuo; Watanabe, Takeo; Kudo, Hiroto

    2017-10-01

    In this paper, we designed the synthesis of negative-type molecular resist materials for EB and EUVL exposure tools, and their properties were examined. The resist materials for EUVL have been required showing higher sensitivity for high throughput in the lithographic process, and expecting lower shot noise to improve a roughness. In EUVL process, the resist materials must be ionized by absorbing EUV to emit more secondary electrons. The EUV absorption of the synthesized resist materials was measured using their thin films on the silicon wafer, and it was observed that the ratio of EUV absorption of the synthesized resist was higher than in the comparison of that of PHS as a reference., i.e., 2.4 times higher absorption was shown. Furthermore, we examined the relationship between the ratios of EUV absorptions and functional groups of the resist materials. As the result, the sensitivity of resist materials under EUV exposure tool was consistent with their structures.

  5. Black Liquid Solar Collector Demonstrator.

    Science.gov (United States)

    Weichman, F. L.; Austen, D. J.

    1979-01-01

    Describes the details of constructing, and use of, a solar collector. Uses a black liquid to absorb the energy, the thermosyphon effect to drive the liquid through the collector, and a floodlamp as a surrogate sun. (GA)

  6. Solar energy collector

    Science.gov (United States)

    Brin, Raymond L.; Pace, Thomas L.

    1978-01-01

    The invention relates to a solar energy collector comprising solar energy absorbing material within chamber having a transparent wall, solar energy being transmitted through the transparent wall, and efficiently absorbed by the absorbing material, for transfer to a heat transfer fluid. The solar energy absorbing material, of generally foraminous nature, absorbs and transmits the solar energy with improved efficiency.

  7. Leaves: Nature's Solar Collectors

    Science.gov (United States)

    Isabelle, Aaron D.; de Groot, Cornelis

    2009-01-01

    One of the most captivating things about plants is the way they capture the Sun's energy, but this can be a difficult topic to cover with elementary students. Therefore, to help students to make a concrete connection to this abstract concept, this series of solar-energy lessons focuses on leaves and how they act as "solar collectors." As students…

  8. Liquid solar collector

    Science.gov (United States)

    1980-01-01

    Report documents evaluation test on commercial flat-plate solar collector that uses water as working fluid. Performance was measured before and after 34-day exposure to natural environment. Tables in metric and English units present data on air and water temperatures, waterflow, insolation, efficiency, and windspeed and direction.

  9. Structurally integrated steel solar collector

    Science.gov (United States)

    Moore, Stanley W.

    1977-03-08

    Herein is disclosed a flat plate solar heat collector unit. The solar collector is integrated as a structural unit so that the collector also functions as the building roof. The functions of efficient heat collection, liquid coolant flow passages, roof structural support and building insulation are combined into one unit.

  10. Solar collector array

    Science.gov (United States)

    Hall, John Champlin; Martins, Guy Lawrence

    2015-09-06

    A method and apparatus for efficient manufacture, assembly and production of solar energy. In one aspect, the apparatus may include a number of modular solar receiver assemblies that may be separately manufactured, assembled and individually inserted into a solar collector array housing shaped to receive a plurality of solar receivers. The housing may include optical elements for focusing light onto the individual receivers, and a circuit for electrically connecting the solar receivers.

  11. Parameters determining the use of zeolite 5A as collector medium in passive flux samplers to estimate N2O emissions from livestock sources.

    Science.gov (United States)

    Larios, Araceli D; Brar, Satinder Kaur; Ramírez, Antonio Avalos; Godbout, Stéphane; Sandoval-Salas, Fabiola; Palacios, Joahnn H; Dubé, Patrick; Delgado, Beatriz; Giroir-Fendler, Anne

    2017-05-01

    The present study analyzes the effect of parameters that determine the use of the zeolite 5A as collector medium in passive flux samplers (PFS) developed to estimate N2O emissions from livestock buildings. The study analyzes the mass of N2O collected on the zeolite 5A as a function of gas flow rate (40 and 130 ml/min), inlet mass of N2O to the PFS (from 7 to 84 μg), adsorbent mass (4 and 13.6 g), length of the adsorbent bed (1.9 and 10.9 cm), and inlet N2O concentration (0.6 and 2 ppmv). The mass of N2O collected on the zeolite 5A ranged from 1.24 to 6.19 μg of N2O/g of adsorbent, which was mainly affected by inlet N2O concentration and mass of adsorbent contained in the PFS. The mass of N2O collected presented a significant relationship with the inlet N2O concentration and the adsorbent bed. Tests were performed using PFS in a laboratory farm under semi-real conditions. It was found that at sampling time of 1.5 h, the accuracy and precision of PFS was appropriate. Under evaluated conditions, a maximum variation between PFS and direct detection of around 12% was estimated.

  12. Turning collectors for solar radiation

    Science.gov (United States)

    Barak, Amitzur Z.

    1976-01-01

    A device is provided for turning a solar collector about the polar axis so that the collector is directed toward the sun as the sun tracks the sky each day. It includes two heat-expansive elements and a shadow plate. In the morning a first expansive element is heated, expands to turn the collector to face the sun, while the second expansive element is shaded by the plate. In the afternoon the second element is heated, expands to turn the collector to face the sun, while the first is shaded by the plate.

  13. Concentrating solar collector - final design

    Science.gov (United States)

    Parker, J. C.

    1980-01-01

    Final report of program to improve commercially available concentrating solar collector describes final hardware, discusses problems encountered, and presents certification statements, photographs, and recommendations for modification.

  14. Integrated solar collector

    Science.gov (United States)

    Tchernev, Dimiter I.

    1985-01-01

    A solar collector having a copper panel in a contiguous space relationship with a condenser-evaporator heat exchanger located under the panel, the panel having a honeycomb-like structure on its interior defining individual cells which are filled with zeolite loaded, in its adsorbed condition, with 18 to 20% by weight of water. The interior of the panel and heat exchanger are maintained at subatmospheric pressure of about 0.1 to 1 psia. The panel and heat exchanger are insulated on their lateral sides and bottoms and on the top of the heat exchange. The panel has a black coating on its top which is exposed to and absorbs solar energy. Surrounding the insulation (which supports the panel) is an extruded aluminum framework which supports a pair of spaced-apart glass panels above the solar panel. Water in conduits from a system for heating or cooling or both is connected to flow into an inlet and discharge from outlet of a finned coil received within the heat exchanger. The collector panel provides heat during the day through desorption and condensing of water vapor from the heated solar panel in the heat exchanger and cools at night by the re-adsorption of the water vapor from the heat exchanger which lowers the absolute pressure within the system and cools the heat exchange coils by evaporation.

  15. Selecting baghouse dust collectors

    Energy Technology Data Exchange (ETDEWEB)

    Moore, S.; Rubak, J.; Jolin, M. [Farr Co., El Segundo, CA (United States)]|[Farr Co., Laval, Quebec (Canada)

    1996-10-01

    Control of nuisance or process dusts generated within a plant is a vital concern with today`s growing emphasis on indoor air quality. In the past, many companies simply moved these contaminants away from workers and discharged them into the atmosphere. More stringent pollution control requirements now make this course of action unacceptable. Also, in some cases there is a need to recover high-value dusts, such as chemicals or precious metals. As a result, proper design and selection of a dust collection system are more critical than ever. There are two types of fabric filter dust collection systems commonly used today: baghouses and cartridges. Baghouses were the first collection systems with fabric media (in the form of long tubes, or bags) for removal of contaminants. The versatility of the baghouse--coupled with constant technological refinements--have made it a long-standing favorite among specifiers of pollution control equipment. In fact, baghouses account for more than 80% of all fabric filter dust collection systems in use today. Cartridge dust collectors use rigidly pleated filter elements instead of bags, making it possible to accommodate a large amount of filter surface area in a comparatively small package. Cartridge collectors also offer high efficiency and low pressure drop.

  16. The PKI collector

    Science.gov (United States)

    Rice, M. P.

    1982-07-01

    The design and manufacturing of a solar thermal collector is discussed. The collector has three primary subsystems: concentrator, receiver/fluid loop, and controls. Identical curved reflective columns are utilized in a faceted Fresnel design to support 864 one foot square flat inexpensive second-surface, silvered glass mirrors. The columns are ganged together and rotated through their centers of gravity to provide elevation tracking. The concentrator is supported by a lightweight spaceframe structure which distributes all wind and gravity loads to the base supports. The base of the structure is a track which rotates on wheels mounted on concrete piers. A parallel tube steel heat exchanger is mounted at the concentrator focal area in a well insulated, galvanized steel housing. Two rows of vertical close-packed, staggered tubes connect a mud header and a steam header. Automatic two axis tracking and operational control is provided with a microprocessor based package. Concentrator-mounted shadowbands are the basis for active tracking. A software program provides azimuthal tracking during cloudy periods.

  17. Colored solar collectors - Annual report 2006

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, A.; Chambrier, E. De; Roecker, Ch.; Scartezzini, J.-L.

    2007-12-15

    The architectural integration of thermal solar collectors into buildings is often limited by their black color, and the visibility of tubes and corrugations of the absorber sheets. A certain freedom in color choice would be desirable, but the colored appearance should not cause an excessive degradation of the collector efficiency. Multilayered thin film interference filters on the collector glazing can produce a colored reflection, hiding the corrugated metal sheet, while transmitting the non-reflected radiation entirely to the absorber. These interference filters are designed and optimized by numerical simulation, and are manufactured by sol-gel dip-coating or magnetron sputtering. The novel colored glazed solar collectors will be ideally suited for architectural integration into buildings, e.g. as solar active glass facades. Due to the tunability of the refractive index, nanostructured materials such as SiO{sub 2}:TiO{sub 2} composites and porous SiO{sub 2} are very useful for application in multilayer interference stacks. Novel quaternary Mg-F-Si-O films exhibit a surprisingly low refractive index and are therefore promising candidates for highly transparent coatings on solar collector glazing. The nanostructure of these thin films is studied by transmission electron microscopy, while the optical constants are measured precisely by ellipsometry. For a convincing demonstration, sufficiently large samples of high quality are imperatively needed. The fabrication of nanocomposite SiO{sub 2}:TiO{sub 2} films has been demonstrated by sol-gel dip-coating of A4-sized glass panes. The produced coatings exhibit a colored reflection in combination with a high solar transmittance, a homogenous appearance, and are free of visible defects. Film hardening by UV exposure will result in speeding up the sol-gel process and saving energy, thereby reducing costs significantly. The infrastructure for UV-curing has been established. A UV C radiation source can now be attached to the

  18. Preliminary design of an air solar collector

    Science.gov (United States)

    1979-01-01

    Report containing performance specifications and engineering drawings of concentric-tube air solar collector show details of collector and subcomponents that indicate efficiency surpassing predetermined performance baseline for air collectors.

  19. Fin-tube solar collectors

    Science.gov (United States)

    1980-01-01

    Report presents test procedures and results of thermal-performance evaluation of seven commercial fin tube (liquid) solar collector-absorber plates. Tests were conducted indoors at Marshall Space Flight Center Solar simulator. Results are graphically shown along with supporting test data and summary, indicating efficiency as function of collector inlet temperature.

  20. High-performance solar collector

    Science.gov (United States)

    Beekley, D. C.; Mather, G. R., Jr.

    1979-01-01

    Evacuated all-glass concentric tube collector using air or liquid transfer mediums is very efficient at high temperatures. Collector can directly drive existing heating systems that are presently driven by fossil fuel with relative ease of conversion and less expense than installation of complete solar heating systems.

  1. LHCb Tag Collector

    CERN Document Server

    Fuente Fernàndez, P; Cousin, N

    2011-01-01

    The LHCb physics software consists of hundreds of packages, each of which is developed by one or more physicists. When the developers have some code changes that they would like released, they commit them to the version control system, and enter the revision number into a database. These changes have to be integrated into a new release of each of the physics analysis applications. Tests are then performed by a nightly build system, which rebuilds various configurations of the whole software stack and executes a suite of run-time functionality tests. A Tag Collector system has been developed using solid standard technologies to cover both the use cases of developers and integration managers. A simple Web interface, based on an AJAX-like technology, is available. Integration with software management and Nightly Build programs is possible via a Python API. Data are stored in a relational database with the help of an ORM (Object-Relational Mapping) library.

  2. Biobriefcase aerosol collector

    Science.gov (United States)

    Bell, Perry M [Tracy, CA; Christian, Allen T [Madison, WI; Bailey, Christopher G [Pleasanton, CA; Willis, Ladona [Manteca, CA; Masquelier, Donald A [Tracy, CA; Nasarabadi, Shanavaz L [Livermore, CA

    2009-09-22

    A system for sampling air and collecting particles entrained in the air that potentially include bioagents. The system comprises providing a receiving surface, directing a liquid to the receiving surface and producing a liquid surface. Collecting samples of the air and directing the samples of air so that the samples of air with particles entrained in the air impact the liquid surface. The particles potentially including bioagents become captured in the liquid. The air with particles entrained in the air impacts the liquid surface with sufficient velocity to entrain the particles into the liquid but cause minor turbulence. The liquid surface has a surface tension and the collector samples the air and directs the air to the liquid surface so that the air with particles entrained in the air impacts the liquid surface with sufficient velocity to entrain the particles into the liquid, but cause minor turbulence on the surface resulting in insignificant evaporation of the liquid.

  3. A Self-Biasing Pulsed Depressed Collector

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, Mark A.; Jensen, Aaron; Neilson, Jeff; /SLAC

    2014-05-29

    Depressed collectors have been utilized successfully for many years to improve the electrical efficiency of vacuum electron devices. Increasingly, pulsed, high-peak power accelerator applications are placing a premium on electrical efficiency. As RF systems are responsible for a large percentage of the overall energy usage at accelerator laboratories, methods to improve upon the state-of-the-art in pulsed high-power sources are desired. This paper presents a technique for self-biasing the stages in a multistage depressed collector. With this technique, the energy lost during the rise and fall times of the pulse can be recovered, separate power supplies are not needed, and existing modulators can be retrofitted. Calculations show that significant cost savings can be realized with the implementation of this device in high-power systems. In this paper, the technique is described along with experimental demonstration. (auth)

  4. Current collectors for improved safety

    Energy Technology Data Exchange (ETDEWEB)

    Abdelmalak, Michael Naguib; Allu, Srikanth; Dudney, Nancy J.; Li, Jianlin; Simunovic, Srdjan; Wang, Hsin

    2017-12-19

    A battery electrode assembly includes a current collector with conduction barrier regions having a conductive state in which electrical conductivity through the conduction barrier region is permitted, and a safety state in which electrical conductivity through the conduction barrier regions is reduced. The conduction barrier regions change from the conductive state to the safety state when the current collector receives a short-threatening event. An electrode material can be connected to the current collector. The conduction barrier regions can define electrical isolation subregions. A battery is also disclosed, and methods for making the electrode assembly, methods for making a battery, and methods for operating a battery.

  5. AEROSOL PARTICLE COLLECTOR DESIGN STUDY

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S; Richard Dimenna, R

    2007-09-27

    A computational evaluation of a particle collector design was performed to evaluate the behavior of aerosol particles in a fast flowing gas stream. The objective of the work was to improve the collection efficiency of the device while maintaining a minimum specified air throughput, nominal collector size, and minimal power requirements. The impact of a range of parameters was considered subject to constraints on gas flow rate, overall collector dimensions, and power limitations. Potential improvements were identified, some of which have already been implemented. Other more complex changes were identified and are described here for further consideration. In addition, fruitful areas for further study are proposed.

  6. Extending the path for efficient extreme ultraviolet sources for advanced nanolithography

    Science.gov (United States)

    Sizyuk, Tatyana; Hassanein, Ahmed

    2015-09-01

    Developing efficient light sources for extreme ultraviolet (EUV) lithography is one of the most important problems of high volume manufacturing (HVM) of the next generation computer chips. Critical components of this technology are continued to face challenges in the demanding performance for HVM. Current investigations of EUV and beyond EUV (BEUV) community are focused on the dual-pulse laser produced plasma (LPP) using droplets of mass-limited targets. Two main objectives as well as challenges in the optimization of these light sources are related to enhancement of the conversion efficiency (CE) of the source and increase components lifetime of the collector optical system. These require significant experimental and computer simulation efforts. These requirements call for fine detail analysis of various plasma physics processes involved in laser target interactions and their effects on source optimization. We continued to enhance our comprehensive HEIGHTS simulation package and upgrade our CMUXE laboratories to study and optimize the efficiency of LPP sources. Integrated modeling and experimental research were done to both benchmark simulation results and to make projections and realistic predictions of the development path for powerful EUVL devices for HVM requirements. We continued the detail analysis of dual-pulse laser systems using various laser wavelengths and delay times between the two pulses. We showed that the efficiency of EUV sources can be improved utilizing the higher harmonics of Nd:YAG laser for the prepulse and the first harmonics for the main pulse, while still having lower efficiency than the combination involving CO2 laser in the range of parameters studied in this case. The differences in optimization process as well as in the source characteristics for two combinations of laser wavelengths were analyzed based on details of atomic and hydrodynamics processes during the evolving plasma plumes.

  7. Accelerated Testing of Solar Collector Durability

    DEFF Research Database (Denmark)

    Svendsen, Sv Aa Højgaard

    1996-01-01

    A climatic simulator has been build to test the reliability and durability of solar collectors. In the climatic simulator the collector is expåosed to extreme climatic conditions and temperature variations in an accelerated way and during this process the function of the collector is tested...... and the microclimate in the collector box is measured....

  8. DESIGN AND THERMAL ANALYSIS OF FIXED AND TRACKING FLAT PLATE COLLECTORS

    OpenAIRE

    *Sudarshan T A

    2016-01-01

    This paper focuses on Thermal efficiency analysis of flat plate collectors. The instantaneous efficiency for a collector over a day is calculated. Application of solar energy for domestic and industrial heating purposes has been become very popular. However the effectiveness of presently used fixed flat plate collectors is low due to the moving nature of the energy source. In the present work, an attempt has been made to compare the performance of fixed flat plate water heater with that of he...

  9. Solar collector manufacturing activity, 1992

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-09

    This report presents data provided by US-based manufacturers and importers of solar collectors. Summary data on solar thermal collector shipments are presented for the years 1974 through 1992. Summary data on photovoltaic cell and module shipments are presented for the years 1982 through 1992. Detailed information for solar thermal collectors and photovoltaic cells and modules are presented for 1992. Appendix A describes the survey methodology. Appendix B contains the 1992 survey forms and instructions. Appendices C and D list the companies that responded to the 1992 surveys and granted permission for their names and addresses to appear in the report. Appendix E provides selected tables from this report with data shown in the International System of Units (SI) metric units. Appendix F provides an estimate of installed capacity and energy production from solar collectors for 1992.

  10. Solar collector with altitude tracking

    Science.gov (United States)

    Barak, Amitzur Z.

    1977-01-01

    A device is provided for turning a solar collector about an east-west horizontal axis so that the collector is tilted toward the sun as the EWV altitude of the sun varies each day. It includes one or more heat responsive elements and a shading means aligned so that within a range of EWV altitudes of the sun during daylight hours the shading means shades the element or elements while during the rest of the daylight hours the elements or elements are heated by the sun to assume heated, stable states. Mechanical linkage between the collector and the element is responsive to the states of the element or elements to tilt the collector in accordance with variations in the EWV altitude of the sun.

  11. Modelling of Microclimate in collectors

    DEFF Research Database (Denmark)

    Holck, Ole

    1996-01-01

    Abstract It is important to avoid condensation in solar collectors, most of all because wetness of the absorber can damage the selective surface and cause corrosion on the absorber plate. During night time the cover of collectors will cool below ambient temperature due to thermal radiation...... to the cold sky. In climates where the air during night time becomes saturated with humidity (the relative humidity is 100%), condensation will form on the outside and inside of the collector glazing. If too much condensation takes place on the inside of the glazing, it will start to fall off...... on to the absorber surface. It is important to characterize microclimatic conditions in the collector, and at the Department of Buildings and Energy work is carried out with the improvement of a computer model. As a tool the computer model will be useful in developing guidelines to achieve the most favourable...

  12. Elastocapillary mist collector

    Science.gov (United States)

    Duprat, Camille; Labbé, Romain; Rewakowicz, Ana

    2015-11-01

    Fibrous media are commonly used to collect droplets from an aerosol. In particular, woven textiles are used to harvest fresh water from fog, and coalescing filters made of non-woven entangled fibers are used to extract oil drops from gas streams. We propose a novel mist collector made of a forest of vertical flexible threads. As the droplets accumulate on the fibers, capillary bridges are formed, leading to the collapse of adjacent fibers thus forming liquid columns. This improve the liquid collection by preventing clogging, enabling high capture and precluding re-entrainment of drops in the gas stream due to the immediate coalescence of incoming droplets, and promoting fast drainage. We find that the collection flow rate is constant and can be adjusted by varying the fibers arrangement and flexibility. We show that there is an optimal situation for which this collection rate, i.e. the global efficiency, is maximal due to an elastocapillary coupling that we further characterize with a model experiment. Specifically, we study the drainage between two flexible fibers. Depending on the geometry and the fiber deformations, several flow regimes are observed. We characterize these regimes, and discuss the consequences on the drainage velocity, and thus the collection efficiency.

  13. ADVANCED HYBRID PARTICULATE COLLECTOR

    Energy Technology Data Exchange (ETDEWEB)

    Stanley J. Miller; Grant L. Schelkoph; Grant E. Dunham

    2000-12-01

    A new concept in particulate control, called an advanced hybrid particulate collector (AHPC), is being developed under funding from the US Department of Energy. The AHPC combines the best features of electrostatic precipitators (ESPs) and baghouses in an entirely novel manner. The AHPC concept combines fabric filtration and electrostatic precipitation in the same housing, providing major synergism between the two methods, both in the particulate collection step and in transfer of dust to the hopper. The AHPC provides ultrahigh collection efficiency, overcoming the problem of excessive fine-particle emissions with conventional ESPs, and solves the problem of reentrainment and recollection of dust in conventional baghouses. Phase I of the development effort consisted of design, construction, and testing of a 5.7-m{sup 3}/min (200-acfm) working AHPC model. Results from both 8-hour parametric tests and 100-hour proof-of-concept tests with two different coals demonstrated excellent operability and greater than 99.99% fine-particle collection efficiency.

  14. SOLAR NANTENNA ELECTROMAGNETIC COLLECTORS

    Energy Technology Data Exchange (ETDEWEB)

    Steven D. Novack; Dale K. Kotter; Dennis Slafer; Patrick Pinhero

    2008-08-01

    This research explores a new efficient approach for producing electricity from the abundant energy of the sun. A nanoantenna electromagnetic collector (NEC) has been designed, prototyped, and tested. Proof of concept has been validated. The device targets mid-infrared wavelengths where conventional photovoltaic (PV) solar cells do not respond but is abundant in solar energy. The initial concept of designing NEC antennas was based on scaling of radio frequency antenna theory. This approach has proven unsuccessful by many due to not fully understanding and accounting for the optical behavior of materials in the THz region. Also until recent years the nanofabrication methods were not available to fabricate the optical antenna elements. We have addressed and overcome both technology barriers. Several factors were critical in successful implementation of NEC including: 1) frequency-dependent modeling of antenna elements, 2) selection of materials with proper THz properties and 3) novel manufacturing methods that enable economical large-scale manufacturing. The work represents an important step toward the ultimate realization of a low-cost device that will collect as well as convert this radiation into electricity, which will lead to a wide spectrum, high conversion efficiency, and low cost solution to complement conventional PVs.

  15. Manifold Insulation for Solar Collectors

    Science.gov (United States)

    1982-01-01

    Results of computer analysis of effects of various manifold insulation detailed in 23-page report show that if fluid is distributed to and gathered from array of solar collectors by external rather than internal manifold, effectiveness of manifold insulation has major influence on efficiency. Report describes required input data and presents equations that govern computer model. Provides graphs comparing collector efficiencies for representative manifold sizes and insulations.

  16. Design package for concentrating solar collector panels

    Science.gov (United States)

    1978-01-01

    Information used to evaluate the design of the Northrup concentrating collector is presented. Included are the system performance specifications, the applications manual, and the detailed design drawings of the collector. The collector is a water/glycol/working fluid type, with a dipped galvanized steel housing, transparent acrylic Fresnel lens cover, copper absorber tube, and fiber glass insulation. It weights 98 pounds. A collector assembly includes four collector units within a tracking mount array.

  17. Solar radiation on a catenary collector

    Science.gov (United States)

    Crutchik, M.; Appelbaum, J.

    1992-01-01

    A tent-shaped structure with a flexible photovoltaic blanket acting as a catenary collector is presented. The shadow cast by one side of the collector produces a shadow on the other side of the collector. This self-shading effect is analyzed. The direct beam, the diffuse, and the albedo radiation on the collector are determined. An example is given for the insolation on the collector operating on Viking Lander 1 (VL1).

  18. Thin film solar energy collector

    Science.gov (United States)

    Aykan, Kamran; Farrauto, Robert J.; Jefferson, Clinton F.; Lanam, Richard D.

    1983-11-22

    A multi-layer solar energy collector of improved stability comprising: (1) a substrate of quartz, silicate glass, stainless steel or aluminum-containing ferritic alloy; (2) a solar absorptive layer comprising silver, copper oxide, rhodium/rhodium oxide and 0-15% by weight of platinum; (3) an interlayer comprising silver or silver/platinum; and (4) an optional external anti-reflective coating, plus a method for preparing a thermally stable multi-layered solar collector, in which the absorptive layer is undercoated with a thin film of silver or silver/platinum to obtain an improved conductor-dielectric tandem.

  19. Performance verification of an air solar collector

    Science.gov (United States)

    Miller, D. C.; Romaker, R. F.

    1979-01-01

    Procedures and results of battery of qualification tests performed by independent certification agency on commercial solar collector are presented in report. Reported results were used as basis in judging collector suitable for field installation in residential and commerical buildings.

  20. Metrology tools for EUV-source characterization and optimization

    Science.gov (United States)

    Missalla, Thomas; Schuermann, Max C.; Lebert, Rainer; Wies, Christian; Juschkin, Larissa; Klein, Roman M.; Scholze, Frank; Ulm, Gerhard; Egbert, Andre; Tkachenko, Boris; Chichkov, Boris N.

    2004-05-01

    The development of suitable radiation sources for extreme ultraviolet lithography (EUVL) is a major challenge. For the optimization of these sources and for the determination of the parameters needed for the system design and the system integration these sources have to be characterized in terms of the absolute in-band power, the spectral distribution in the EUV spectral region and the out-of-band spectral regions, the spatial distribution of the emitting volume and the angular distribution of the emission. For improving the lifetime of such sources, generally accepted as one key risk with EUVL, another task, the debris emitted from sources under development has to be investigated. Therefore, JENOPTIK Mikrotechnik GmbH is co-operating with the Laser Laboratorium Goettingen, the Physikalisch-Technische Bundesanstalt (PTB) and the AIXUV GmbH in developing ready-for-use metrology tools for EUVL source characterization and optimization. The set of the tools employed for EUV-source characterization is presented in detail as well as concepts for calibration and measurement procedures.

  1. Opensource Software for MLR-Modelling of Solar Collectors

    DEFF Research Database (Denmark)

    Bacher, Peder; Perers, Bengt

    2011-01-01

    A first research version is now in operation of a software package for multiple linear regression (MLR) modeling and analysis of solar collectors according to ideas originating all the way from Walletun et. al. (1986), Perers, (1987 and 1993). The tool has been implemented in the free and open...... source program R http://www.r-project.org/. Applications of the software package includes: visual validation, resampling and conversion of data, collector performance testing analysis according to the European Standard EN 12975 (Fischer et al., 2004), statistical validation of results...... with a new Excel tool connected to EN 12975 (Kovacs, 2011) this built in validation gives an extra quality assurance....

  2. Investigations on efficiencies of HT solar collectors for different flow rates and collector tilts

    DEFF Research Database (Denmark)

    Chen, Ziqian; Perers, Bengt; Furbo, Simon

    2013-01-01

    Two HT solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one solar collector is equipped with an ETFE foil between the abso......Two HT solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one solar collector is equipped with an ETFE foil between...... the absorber and the cover glass and the other is without ETFE foil. The efficiencies for the collectors are tested at different flow rates and tilt. On the basis of the measured efficiencies, the efficiencies for the collectors as functions of flow rates are obtained. The calculated efficiencies are in good...

  3. Theoretical and experimental investigations of Chinese evacuated tubular solar collectors

    DEFF Research Database (Denmark)

    Qin, Lin; Furbo, Simon

    1999-01-01

    Four different marketed Chinese evacuated tubular solar collectors have been investigated both theoretically and experimentally. The advantages of the investigated solar collectors compared to normal flat plate collectors were elucidated.......Four different marketed Chinese evacuated tubular solar collectors have been investigated both theoretically and experimentally. The advantages of the investigated solar collectors compared to normal flat plate collectors were elucidated....

  4. Engineering of solar photocatalytic collectors

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, S.M.; Galvez, J.B.; Rubio, M.I.M.; Ibanez, P.F.; Padilla, D.A. [Plataforma Solar de Almeria (CIEMAT) (Spain); Pereira, M.C.; Mendes, J.F. [Instituto Nacional de Engenharia e Tecnologica Industrial, Lisbon (Portugal); Correia de Oliveira, J. [Aosol Energias Renovaveis Lda, Porto Alto (Portugal)

    2004-11-01

    This paper briefly describes the different collectors used in solar photocatalysis for wastewater treatment and, based on prior experience, the main advantages and disadvantages of each. As the tubular-shape reactor configuration is the most appropriate for handling and pumping water, the compound parabolic collector (CPC) is proposed as an interesting combination of parabolic concentrators and flat static systems and constitutes a good option for solar photochemical applications. The design of compound parabolic concentrators for solar photocatalytic applications is described in detail and 25-50 mm is proposed as the optimum photoreactor diameter, based on the optical characteristics and optimum concentration of the two photocatalytic systems (TiO{sub 2} and photo-Fenton) that can be used with sunlight for wastewater treatment. It has been demonstrated that since aluminium is the only metal that is highly reflective in the ultraviolet spectrum of solar radiation, aluminium-based mirrors are the best option. But, especially when exposed to outdoor conditions, aluminium must be protected and, therefore, at the present time, anodised and electropolished aluminium surfaces are considered the most suitable solutions. As the photochemical reactor contain the working fluid, including the catalyst, it must transmit UV sunlight efficiently and be able to work under enough pressure to handle the high volumes resulting from the large number of collectors in an industrial treatment plant, only low-iron glass is proposed as feasible for constructing the photoreactor (collector absorbers). Finally, ray-tracing algorithm simulations are presented as a design tool for the optical configuration of a particular reactor, drawing conclusions for its improvement and assisting in final engineering decision-making. (Author)

  5. Fog collectors and collection techniques

    Science.gov (United States)

    Höhler, I.; Suau, C.

    2010-07-01

    The earth sciences taught that due to the occurrence of water in three phases: gas, liquid and solid, solar energy keeps the hydrological cycle going, shaping the earth surface while regulating the climate and thus allowing smart technologies to interfere in the natural process by rerouting water and employing its yield for natural and human environments’ subsistence. This is the case of traditional fog collectors implemented by several researchers along the Atacama Desert since late ’50s such as vertical tensile mesh or macro-diamonds structures. Nevertheless, these basic prototypes require to be upgraded, mainly through new shapes, fabrics and frameworks’ types by following the principles of lightness, transformability, portability and polyvalence. The vertical canvas of conventional fog collectors contain too much stressed at each joints and as result it became vulnerable. Our study constitutes a research by design of two fog-trap devices along the Atacama Desert. Different climatic factors influence the efficiency of fog harvesting. In order to increase yield of collected fog water, we need to establish suitable placements that contain high rates of fog’s accumulation. As important as the location is also the building reliability of these collectors that will be installed. Their frames and skins have to be adjustable to the wind direction and resistant against strong winds and rust. Its fabric need to be more hydrophobic, elastic and with light colours to ease dripping/drainage and avoid ultra-violet deterioration. In addition, meshes should be well-tensed and frames well-embraced too. In doing so we have conceived two fog collectors: DropNet© (Höhler) and FogHive© (Suau). These designs explore climatic design parameters combined with the agile structural principles of Tensegrity and Geodesic widely developed by Bucky Fuller and Frei Otto. The research methods mainly consisted of literature review; fieldwork; comparative analysis of existing fog

  6. Physical processes in EUV sources for microlithography

    Energy Technology Data Exchange (ETDEWEB)

    Banine, V Y; Swinkels, G H P M [ASML Netherlands B.V., De Run 6501, 5504DR Veldhoven (Netherlands); Koshelev, K N [Institute of Spectroscopy RAS (ISAN), Fizicheskaya 5, Troitsk 142190 (Russian Federation)

    2011-06-29

    The source is an integral part of an extreme ultraviolet lithography (EUVL) tool. Such a source, as well as the EUVL tool, has to fulfil very high demands both technical and cost oriented. The EUVL tool operates at a wavelength of 13.5 nm, which requires the following new developments. - The light production mechanism changes from conventional lamps and lasers to relatively high-temperature emitting plasmas. - The light transport, mainly refractive for deep ultraviolet (DUV), should be reflective for EUV. - The source specifications as derived from the customer requirements on wafer throughput mean that the output EUV source power has to be hundreds of watts. This in its turn means that tens to hundreds of kilowatts of dissipated power has to be managed in a relatively small volume. - In order to keep lithography costs as low as possible, the lifetime of the components should be as long as possible and at least of the order of thousands of hours. This poses a challenge for the sources, namely how to design and manufacture components robust enough to withstand the intense environment of high heat dissipation, flows of several keV ions as well as the atomic and particular debris within the source vessel. - As with all lithography tools, the imaging requirements demand a narrow illumination bandwidth. Absorption of materials at EUV wavelengths is extreme with extinguishing lengths of the order of tens of nanometres, so the balance between high transmission and spectral purity requires careful engineering. All together, EUV lithography sources present technological challenges in various fields of physics such as plasma, optics and material science. These challenges are being tackled by the source manufacturers and investigated extensively in the research facilities around the world. An overview of the published results on the topic as well as the analyses of the physical processes behind the proposed solutions will be presented in this paper. (topical review)

  7. Temperature comparison of different reflective surfaces of a solar thermal collector

    Science.gov (United States)

    Koh, Yit Yan; Chua, Yaw Long; Chin, Kiat Keong

    2017-09-01

    With the rapid depletion of fossil fuels, the search for application of alternative energy sources becomes more important than ever before. Solar energy has been identified as one of the major renewable energy that will contribute to power generation is years to come. There are two major categories of solar energy applications. Solar thermal collector is one of it. This paper presents an investigation on the effect of different reflecting surfaces on solar thermal collector. Three different reflective surfaces were applied on the surface of the solar thermal collector. Data was collected and analyzed. From the results, the aluminum mirror sheet performed best.

  8. Automated solar collector installation design

    Science.gov (United States)

    Wayne, Gary; Frumkin, Alexander; Zaydman, Michael; Lehman, Scott; Brenner, Jules

    2014-08-26

    Embodiments may include systems and methods to create and edit a representation of a worksite, to create various data objects, to classify such objects as various types of pre-defined "features" with attendant properties and layout constraints. As part of or in addition to classification, an embodiment may include systems and methods to create, associate, and edit intrinsic and extrinsic properties to these objects. A design engine may apply of design rules to the features described above to generate one or more solar collectors installation design alternatives, including generation of on-screen and/or paper representations of the physical layout or arrangement of the one or more design alternatives.

  9. Optimization of dish solar collectors

    Science.gov (United States)

    Jaffe, L. D.

    1983-01-01

    Methods for optimizing parabolic dish solar collectors and the consequent effects of various optical, thermal, mechanical, and cost variables are examined. The most important performance optimization is adjusting the receiver aperture to maximize collector efficiency. Other parameters that can be adjusted to optimize efficiency include focal length, and, if a heat engine is used, the receiver temperature. The efficiency maxima associated with focal length and receiver temperature are relatively broad; it may, accordingly, be desirable to design somewhat away from the maxima. Performance optimization is sensitive to the slope and specularity errors of the concentrator. Other optical and thermal variables affecting optimization are the reflectance and blocking factor of the concentrator, the absorptance and losses of the receiver, and, if a heat engine is used, the shape of the engine efficiency versus temperature curve. Performance may sometimes be improved by use of an additional optical element (a secondary concentrator) or a receiver window if the errors of the primary concentrator are large or the receiver temperature is high. Previously announced in STAR as N83-19224

  10. Development of a Solar Assisted Drying System Using Double-Pass Solar Collector with Finned Absorber

    Science.gov (United States)

    Azmi, M. S. M.; Othman, M. Y.; Sopian, K.; Ruslan, M. H.; Majid, Z. A. A.; Fudholi, A.; Yasin, J. M.

    2012-09-01

    The Solar Energy Research Group, Universiti Kebangsaan Malaysia, International Islamic University Malaysia and Yayasan FELDA has designed and constructed a solar assisted drying system at OPF FELDA Factory, Felda Bukit Sagu 2, Kuantan, Pahang. The drying system has a total of six double-pass solar collectors. Each collector has a length of 480 cm and a width of 120 cm. The first channel depth is 3.5 cm and the second channel depth is 7 cm. Longitudinal fins made of angle aluminium, 0.8 mm thickness were attached to the bottom surface of the absorber plate. The solar collectors are arranged as two banks of three collectors each in series. Internal manifold are used to connect the collectors. Air enters through the first channel and then through the second channel of the collector. An auxiliary heater source is installed to supply heat under unfavourable solar radiation condition. An on/off controller is used to control the startup and shutdown of the auxiliary heater. An outlet temperature of 70-75 °C can be achieved at solar radiation range of 800-900 W/m2 and flow rate of 0.12 kg/s. The average thermal efficiency of a solar collector is approximately 37%.

  11. Development of a dust collector inlet hood for enhanced surface mine drill dust capture

    Energy Technology Data Exchange (ETDEWEB)

    John A. Organiscak; Steven J. Page [National Institute for Occupational Safety & Health, Pittsburgh, PA (United States). Pittsburgh Research Laboratory, Department of Health & Human Services, Centers for Disease Control and Prevention

    2005-03-01

    Surface mine drill operators have the highest frequency of overexposure to quartz dust, and drilling is one of the occupations associated with the highest incidence of silicosis. Previous field assessment studies of drilling machines indicate that they can emit some of the highest airborne respirable quartz dust concentrations found at surface mining operations. Typically, the surface mine drills are equipped with dry dust collector systems to capture the dust being flushed with compressed air from the hole during the drilling process. The overall control effectiveness of the dust collector system is initially dependent on capturing the dust cloud at the source via the collector inlet. To assist the initial capture of the dust being flushed from the drill hole, the bottom of the drill deck is typically shrouded or enclosed on all sides to help contain the dust for the collector inlet plenum located on the underside perimeter of the drill deck. Openings, gaps and breaches in the shroud enclosure permit dust to escape dust collector capture. The National Institute for Occupational Safety and Health (NIOSH) has developed a collector inlet hood that reconfigures the inlet plenum around the drill steel and above the hole to enhance dust capture. Laboratory development and testing show that this inlet hood improves dust capture by an average of nearly 50% over a wide range of collector flows and shroud leakage areas. This report describes the laboratory and subsequent field testing of this inlet hood concept.

  12. Foldable Frame Supporting Electromagnetic Radiation Collectors

    DEFF Research Database (Denmark)

    2011-01-01

    The present invention relates to flexible frames supporting electromagnetic radiation collectors, such as antennas, antenna reflectors, deflectors or solar collectors, for celestial or terrestrial applications, which can be folded to be stored and/or transported. The method for stowing deforms...

  13. Cleaner for Solar-Collector Covers

    Science.gov (United States)

    Frickland, P. O.; Cleland, E. L.

    1983-01-01

    Simple self-contained cleaning system proposed for solar collectors or solar-collector protective domes. Perforated transparent plastic cap attached to top of protective dome in heliostat solar-energy collection system distributes cleaning fluid over surface of dome without blocking significant fraction of solar radiation.

  14. Solar collector with improved thermal concentration

    Science.gov (United States)

    Barak, Amitzur Z.

    1976-01-01

    Reduced heat loss from the absorbing surface of the energy receiver of a cylindrical radiant energy collector is achieved by providing individual, insulated, cooling tubes for adjacent parallel longitudinal segments of the receiver. Control means allow fluid for removing heat absorbed by the tubes to flow only in those tubes upon which energy is then being directed by the reflective wall of the collector.

  15. Design review of a liquid solar collector

    Science.gov (United States)

    Wiesewmaier, B. L.

    1979-01-01

    Report documents procedures, results, and recommendations for in-depth analysis of problems with liquid-filled version of concentric-tube solar collector. Problems are related to loss of vacuum and/or violent fracture of collector elements, fluid leakage, freezing, flow anomalies, manifold damage, and other component failures.

  16. Combined solar collector and energy storage system

    Science.gov (United States)

    Jensen, R. N. (Inventor)

    1980-01-01

    A combined solar energy collector, fluid chiller and energy storage system is disclosed. A movable interior insulated panel in a storage tank is positionable flush against the storage tank wall to insulate the tank for energy storage. The movable interior insulated panel is alternately positionable to form a solar collector or fluid chiller through which the fluid flows by natural circulation.

  17. Weathering of a liquid solar collector

    Science.gov (United States)

    1980-01-01

    Commercially available flate plate hot water solar collector is characterized in report that presents 10 month weathering study of system. Collector efficiency was calculated and plotted from measurements of fluid temperature and flow rate, ambient temperature and solar flux. Windspeed and wind direction were also measured during tests.

  18. Review of state-of-the-art of solar collector corrosion processes. Task 1 of solar collector studies for solar heating and cooling applications. Final technical progress report

    Energy Technology Data Exchange (ETDEWEB)

    Clifford, J E; Diegle, R B

    1980-04-11

    The state-of-the-art of solar collector corrosion processes is reviewed, and Task 1 of a current research program on use of aqueous heat transfer fluids for solar heating and cooling is summarized. The review of available published literature has indicated that lack of quantitative information exists relative to collector corrosion at the present time, particularly for the higher temperature applications of solar heating and cooling compared to domestic water heating. Solar collector systems are reviewed from the corrosion/service life viewpoint, with emphasis on various applications, collector design, heat transfer fluids, and freeze protection methods. Available information (mostly qualitative) on collector corrosion technology is reviewed to indicate potential corrosion problem areas and corrosion prevention practices. Sources of limited quantitative data that are reviewed are current solar applications, research programs on collector corrosion, and pertinent experience in related applications of automotive cooling and non-solar heating and cooling. A data bank was developed to catalog corrosion information. Appendix A of this report is a bibliography of the data bank, with abstracts reproduced from presently available literature accessions (about 220). This report is presented as a descriptive summary of information that is contained in the data bank.

  19. Electrostatic particle collector with improved features for installing and/or removing its collector plates

    Energy Technology Data Exchange (ETDEWEB)

    Siegfried, Matthew J.; Radford, Daniel R.; Huffman, Russell K.

    2017-04-04

    An electrostatic particle collector may generally include a housing having sidewalls extending lengthwise between a first end and a second end. The housing may define a plate slot that extends heightwise within the housing between a top end and a bottom end. The housing may further include a plate access window that provides access to the bottom end of the plate slot. The collector may also include a collector plate configured to be installed within the plate slot that extends heightwise between a top edge and a bottom edge. Additionally, when the collector plate is installed within the plate slot, the bottom edge of the collector plate may be accessible from an exterior of the housing via the plate access window so as to allow the bottom edge of the collector plate to be moved relative to the housing to facilitate removal of the collector plate from the housing.

  20. Nocturnal radiation from a solar collector

    Science.gov (United States)

    Wang, H. F.; Chiang, C. W.

    1980-11-01

    As the sky temperature during the night is relatively low compared to the ambient temperature, the temperature of the absorber plate in a solar collector can be lower than the ambient temperature due to nocturnal radiation. Measurements have been made for Lennox Solar Collectors installed in a solar heating and cooling project, a same collector in Rapid City and a simple home-made collector in the laboratory. The home-made collector consists of a brass-copper plate sprayed with flat-black paint, covered with glass sheets and boxed with two inch thick styrofoam insulation. A cooling as much as 10 C in winter has been observed. It is expected to be appreciably more in summer. This suggests a potential utilization of nocturnal radiation for air conditioning. Theoretical analysis is presented.

  1. Mobile Collector for Field Trips

    Directory of Open Access Journals (Sweden)

    Lucia Terrenghi

    2004-04-01

    Full Text Available Current e-Learning is based on learning management systems that provide certain standard services - course authoring and delivery, tutoring, administration and collaboration facilities. Rapid development of mobile technologies opens a new area of m-Learning to enhance the current educational opportunities. Field trips are a relevant part of the curriculum, but for various reasons it is often difficult to organize them. The aim of the RAFT project is development of a system that would enable virtual field trips. One mobile learning application prototype created in this project, called Mobile Collector, enables data gathering and annotation in the field, together with real time collaboration. The application supports learner-centred education in real world context.

  2. COMPARATIVE FIELD EXPERIMENTAL INVESTIGATIONS OF DIFFERENT FLAT PLATE SOLAR COLLECTORS

    Directory of Open Access Journals (Sweden)

    Guangming Chen

    2015-12-01

    Full Text Available Full-scale traditional metal solar collectors and solar collector specimens fabricated from polymeric materials were investigated in the present study. A polymeric collector is 67.8% lighter than a traditional metal solar collector, and a metal solar collector with transparent plastic covering is 40.3% lighter than a traditional metal solar collector. Honeycomb multichannel plates made from polycarbonate were chosen to create a polymeric solar collector. A test rig for the natural circulation of the working fluid in a solar collector was built for a comparative experimental investigation of various solar collectors operating at ambient conditions. It was shown experimentally that the efficiency of a polymeric collector is 8–15% lower than the efficiency of a traditional collector.

  3. Next Generation Solar Collectors for CSP

    Energy Technology Data Exchange (ETDEWEB)

    Molnar, Attila [3M Company, St. Paul, MN (United States); Charles, Ruth [3M Company, St. Paul, MN (United States)

    2014-07-31

    The intent of “Next Generation Solar Collectors for CSP” program was to develop key technology elements for collectors in Phase 1 (Budget Period 1), design these elements in Phase 2 (Budget Period 2) and to deploy and test the final collector in Phase 3 (Budget Period 3). 3M and DOE mutually agreed to terminate the program at the end of Budget Period 1, primarily due to timeline issues. However, significant advancements were achieved in developing a next generation reflective material and panel that has the potential to significantly improve the efficiency of CSP systems.

  4. Baghouse and cartridge dust collectors: A comparison

    Energy Technology Data Exchange (ETDEWEB)

    Grafe, T.; Kelley, G. (Torit and Day, Minneapolis, MN (United States))

    1993-09-01

    Increased demands are being placed on air filtration systems. The particular application will determine whether a baghouse or cartridge type is best. Baghouse and cartridge dust collectors both have their place in modern air filtering systems. Baghouses have been in use much longer, but cartridge types offer significant advantages for particular applications. The task facing the site engineer is to match the requirements of the specific application with the inherent characteristics of the dust collector. This article presents basic information about both types of dust collectors that can help provide the best solution to that problem.

  5. Improved Large Aperture Collector Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    O' Rourke, Deven [Abengoa Solar LLC, Lakewood, CO (United States); Farr, Adrian [Abengoa Solar LLC, Lakewood, CO (United States)

    2015-12-01

    The parabolic trough is the most established CSP technology and carries a long history of design experimentation dating back to the 1970’s. This has led to relatively standardized collector architectures, a maturing global supply chain, and a fairly uniform cost reduction strategy. Abengoa has deployed more than 1,500MWe of CSP troughs across several countries and has built and tested full-scale prototypes of many R&D concepts. The latest trough R&D efforts involved efforts to internalize non-CSP industry experience including a preliminary DFMA principles review done with Boothroyd Dewhurst, a construction literature review by the Arizona State University School of Construction Management, and two more focused manufacturing engineering subcontracts done by Ricardo Inc. and the nonprofit Edison Welding Institute. The first two studies highlighted strong opportunities in lowering part count, standardizing components and fasteners, developing modular designs to support prefabrication and automation, and devising simple, error-proof manual assembly methods. These principles have delivered major new cost savings in otherwise “mature” products in analogous industries like automotive, truck trailer manufacture, metal building fabrication, and shipbuilding. For this reason, they were core in the design development of the SpaceTube® collector, and arguably key to its early successes. The latter two studies were applied specifically to the first-generation SpaceTube® design and were important in setting the direction of the present SolarMat project. These studies developed a methodology to analyze the costs of manufacture and assembly, and identify new tooling concepts for more efficient manufacture. Among the main opportunities identified in these studies were the automated mirror arm manufacturing concept and the need for a less infrastructure-intensive assembly line, both of which now form central pillars of the SolarMat project strategy. These new designs will be

  6. A thermal comparison among several beverage can solar collectors.

    Science.gov (United States)

    Peter Y.S. Chen

    1984-01-01

    Four air-heated solar collectors were built using four different configurations of aluminum beverage cans. The collectors were then tested for four consecutive seasons for their daily efficiencies. One of the collectors was also evaluated for one season for the effect of air velocity on efficiency, temperature rise, and power consumption of the collector.

  7. Performance after weathering of a liquid solar collector

    Science.gov (United States)

    1979-01-01

    Results from retesting of liquid solar collector described in "Performance evaluation of liquid collector" (M-FS-23931), after long term exposure to natural weathering indicate no detectable degradation in collector performance and no visable deterioration in appearance of collector. Supporting data and pretest/post test efficiency comparison are included.

  8. Collector/Receiver Characterization (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2010-08-01

    Fact sheet describing NREL CSP Program capabilities for collector/receiver characterization: determining optical efficiency, measuring heat loss, developing and testing concentrators, concentrating the sun's power, and optically characterizing CSP plants.

  9. Certification of the concentrating solar collector

    Science.gov (United States)

    1980-01-01

    Report describes procedures and results of extensive testing of concentrating solar collector performed for certification of systems compliance with government performance standards. Test includes operational, electrical, mechanical, and thermal checks, as well as structural integrity.

  10. Tilt assembly for tracking solar collector assembly

    Science.gov (United States)

    Almy, Charles; Peurach, John; Sandler, Reuben

    2012-01-24

    A tilt assembly is used with a solar collector assembly of the type comprising a frame, supporting a solar collector, for movement about a tilt axis by pivoting a drive element between first and second orientations. The tilt assembly comprises a drive element coupler connected to the drive element and a driver, the driver comprising a drive frame, a drive arm and a drive arm driver. The drive arm is mounted to the drive frame for pivotal movement about a drive arm axis. Movement on the drive arm mimics movement of the drive element. Drive element couplers can extend in opposite directions from the outer portion of the drive arm, whereby the assembly can be used between adjacent solar collector assemblies in a row of solar collector assemblies.

  11. Wind loading on solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Bhaduri, S.; Murphy, L.M.

    1985-06-01

    The present design methodology for the determination of wind loading on the various solar collectors has been reviewed and assessed. The total force coefficients of flat plates of aspect ratios 1.0 and 3.0, respectively, at various angles of attack obtained by using the guidelines of the ANSI A58.1-1982, have been compared with those obtained by using the methodology of the ASCE Task Committee, 1961, and the experimental results of the full-scale test of heliostats by Peglow. The turbulent energy spectra, currently employed in the building code, are compared with those of Kaimal et al., Lumley, and Ponofsky for wind velocities of 20.0 m/s and 40.24 m/s at an elevation of 9.15 m. The longitudinal spectra of the building code overestimates the Kaimal spectra in the frequency range of 0.007 Hz to 0.08 Hz and underestimates beyond the frequency of 0.08 Hz. The peak angles of attack, on the heliostat, stowed in horizontal position, due to turbulent vertical and lateral components of wind velocity, have been estimated by using Daniel's methodology for three wind velocities and compared with the value suggested by the code. The experimental results of a simple test in the laboratory indicate the feasibility of decreasing the drag forces of the flat plate by reducing the solidity ratio.

  12. Local Reasoning about a Copying Garbage Collector

    DEFF Research Database (Denmark)

    Torp-Smith, Noah; Birkedal, Lars; Reynolds, John C.

    2008-01-01

    We present a programming language, model, and logic appropriate for implementing and reasoning about a memory management system. We state semantically what is meant by correctness of a copying garbage collector, and employ a variant of the novel separation logics to formally specify partial...... correctness of Cheney’s copying garbage collector in our program logic. Finally, we prove that our implementation of Cheney’s algorithm meets its specification using the logic we have given and auxiliary variables. Udgivelsesdato: 2008...

  13. Evaluation of combined photovoltaic/thermal collectors

    Energy Technology Data Exchange (ETDEWEB)

    Hendrie, S.D.

    1979-01-01

    The thermal and electric performance of an air and a liquid type combined photovoltaic/thermal solar collector has been evaluated, yielding close correlation with theoretical results. Maximum thermal efficiencies of 42.5% and 40% for the liquid and air collectors without electric power production decreased to 40.4% and 32.9% when electrical power was produced. Maximum electrical efficiencies of 6.8% were measured.

  14. Thermal performance of evacuated tube heat pipe solar collector

    Science.gov (United States)

    Putra, Nandy; Kristian, M. R.; David, R.; Haliansyah, K.; Ariantara, Bambang

    2016-06-01

    The high fossil energy consumption not only causes the scarcity of energy but also raises problems of global warming. Increasing needs of fossil fuel could be reduced through the utilization of solar energy by using solar collectors. Indonesia has the abundant potential for solar energy, but non-renewable energy sources still dominate energy consumption. With heat pipe as passive heat transfer device, evacuated tube solar collector is expected to heat up water for industrial and home usage without external power supply needed to circulate water inside the solar collector. This research was conducted to determine the performance of heat pipe-based evacuated tube solar collector as solar water heater experimentally. The experiments were carried out using stainless steel screen mesh as a wick material, and water and Al2O3-water 0.1% nanofluid as working fluid, and applying inclination angles of 0°, 15°, 30°, and 45°. To analyze the heat absorbed and transferred by the prototype, water at 30°C was circulated through the condenser. A 150 Watt halogen lamp was used as sun simulator, and the prototype was covered by an insulation box to obtain a steady state condition with a minimum affection of ambient changes. Experimental results show that the usage of Al2O3-water 0.1% nanofluid at 30° inclination angle provides the highest thermal performance, which gives efficiency as high as 0.196 and thermal resistance as low as 5.32 °C/W. The use of nanofluid as working fluid enhances thermal performance due to high thermal conductivity of the working fluid. The increase of the inclination angle plays a role in the drainage of the condensate to the evaporator that leads to higher thermal performance until the optimal inclination angle is reached.

  15. Step tracking program for concentrator solar collectors

    Science.gov (United States)

    Ciobanu, D.; Jaliu, C.

    2016-08-01

    The increasing living standards in developed countries lead to increased energy consumption. The fossil fuel consumption and greenhouse gas effect that accompany the energy production can be reduced by using renewable energy. For instance, the solar thermal systems can be used in temperate climates to provide heating during the transient period or cooling during the warmer months. Most used solar thermal systems contain flat plate solar collectors. In order to provide the necessary energy for the house cooling system, the cooling machine uses a working fluid with a high temperature, which can be supplied by dish concentrator collectors. These collectors are continuously rotated towards sun by biaxial tracking systems, process that increases the consumed power. An algorithm for a step tracking program to be used in the orientation of parabolic dish concentrator collectors is proposed in the paper to reduce the consumed power due to actuation. The algorithm is exemplified on a case study: a dish concentrator collector to be implemented in Brasov, Romania, a location with the turbidity factor TR equal to 3. The size of the system is imposed by the environment, the diameter of the dish reflector being of 3 meters. By applying the proposed algorithm, 60 sub-programs are obtained for the step orientation of the parabolic dish collector over the year. Based on the results of the numerical simulations for the step orientation, the efficiency of the direct solar radiation capture on the receptor is up to 99%, while the energy consumption is reduced by almost 80% compared to the continuous actuation of the concentrator solar collector.

  16. Two new designs of parabolic solar collectors

    Directory of Open Access Journals (Sweden)

    Karimi Sadaghiyani Omid

    2014-01-01

    Full Text Available In this work, two new compound parabolic trough and dish solar collectors are presented with their working principles. First, the curves of mirrors are defined and the mathematical formulation as one analytical method is used to trace the sun rays and recognize the focus point. As a result of the ray tracing, the distribution of heat flux around the inner wall can be reached. Next, the heat fluxes are calculated versus several absorption coefficients. These heat flux distributions around absorber tube are functions of angle in polar coordinate system. Considering, the achieved heat flux distribution are used as a thermal boundary condition. After that, Finite Volume Methods (FVM are applied for simulation of absorber tube. The validation of solving method is done by comparing with Dudley's results at Sandia National Research Laboratory. Also, in order to have a good comparison between LS-2 and two new designed collectors, some of their parameters are considered equal with together. These parameters are consist of: the aperture area, the measures of tube geometry, the thermal properties of absorber tube, the working fluid, the solar radiation intensity and the mass flow rate of LS-2 collector are applied for simulation of the new presented collectors. After the validation of the used numerical models, this method is applied to simulation of the new designed models. Finally, the outlet results of new designed collector are compared with LS-2 classic collector. Obviously, the obtained results from the comparison show the improving of the new designed parabolic collectors efficiency. In the best case-study, the improving of efficiency are about 10% and 20% for linear and convoluted models respectively.

  17. Heat Pumps With Direct Expansion Solar Collectors

    Science.gov (United States)

    Ito, Sadasuke

    In this paper, the studies of heat pump systems using solar collectors as the evaporators, which have been done so far by reserchers, are reviwed. Usually, a solar collector without any cover is preferable to one with ac over because of the necessity of absorbing heat from the ambient air when the intensity of the solar energy on the collector is not enough. The performance of the collector depends on its area and the intensity of the convective heat transfer on the surface. Fins are fixed on the backside of the collector-surface or on the tube in which the refrigerant flows in order to increase the convective heat transfer. For the purpose of using a heat pump efficiently throughout year, a compressor with variable capacity is applied. The solar assisted heat pump can be used for air conditioning at night during the summer. Only a few groups of people have studied cooling by using solar assisted heat pump systems. In Japan, a kind of system for hot water supply has been produced commercially in a company and a kind of system for air conditioning has been installed in buildings commercially by another company.

  18. Optimum solar collector fluid flow rates

    DEFF Research Database (Denmark)

    Furbo, Simon; Shah, Louise Jivan

    1996-01-01

    Experiments showed that by means of a standard electronically controlled pump, type UPE 2000 from Grundfos it is possible to control the flow rate in a solar collector loop in such a way that the flow rate is strongly influenced by the temperature of the solar collector fluid passing the pump...... the energy consumption of a normal ciculation pump in the solar heating system.Calculations showed that the highest thermal performances for small SDHW systems based on mantle tanks with constant volume flow rates in the solar collector loops are achieved if the flow rate is situated in the interval from 0.......2 to 0.3 l/min. per m^2 solar collector for combi tank systems and in the interval from 0.3 to 0.4 l/min. per m^2 solar collector for preheating systems. Further, calculations showed that by means of an advanced control strategy for the flow rate - for instance if the flow rate is directly proportional...

  19. Mathematical model of heat-mass exchange processes in a flat solar collector SUN 1

    Directory of Open Access Journals (Sweden)

    Tunik Aleksandr Aleksandrovich

    2016-01-01

    Full Text Available In a flat solar collector SUN 1 The active development of environmental friendly energy sources alternative to HPPs is currently of great importance in the world. Such alternative energy sources are: water, ground, sun, wind, biofuel, etc. If we have a look at the atlas of solar energy resources on the territory of Russia, we can make a conclusion, that in many regions of our country solar activity level allows using solar collector. Though the analysis of different models of solar collector showed, that most of them are ineffective in the regions with cold climate, though the solar activity of these regions is of a great level. In this regard, a mathematical model of heat-mass exchange processes in flat solar collectors is introduced in this article. The model was a basis for the development of a new solar collector, named SUN 1, which has an original heating tubes form. This form allows heat transfer medium to be under the influence of solar energy for a longer time and consequently to warm to a higher temperature, increasing the warming rapidity.

  20. Efficiencies of flat plate solar collectors at different flow rates

    DEFF Research Database (Denmark)

    Chen, Ziqian; Furbo, Simon; Perers, Bengt

    2012-01-01

    Two flat plate solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one collector is equipped with an ETFE foil between...... the absorber and the cover glass and the other is without ETFE foil. The efficiencies for the collectors are tested at different flow rates. On the basis of the measured efficiencies, the efficiencies for the collectors as functions of flow rate are obtained. The calculated efficiencies are in good agreement...

  1. Short-Term Solar Collector Power Forecasting

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Perers, Bengt

    2011-01-01

    This paper describes a new approach to online forecasting of power output from solar thermal collectors. The method is suited for online forecasting in many applications and in this paper it is applied to predict hourly values of power from a standard single glazed large area flat plate collector......, such as wind power. In such a scenario online forecasting is a vital tool for optimal control and utilization of solar heating systems. The method is a two-step scheme, where first a non-linear model is applied to transform the solar power into a stationary process, which then is forecasted with robust time......-adaptive linear models. The approach is similar to the one by Bacher et al. (2009), but contains additional effects due to differences between solar thermal collectors and photovoltaics. Numerical weather predictions provided by Danish Meteorological Institute are used as input. The applied models adapt over time...

  2. Qualification test and analysis report: solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    1978-12-01

    Test results show that the Owens-Illinois Sunpak/sup TM/ Model SEC 601 air-cooled collector meets the national standards and codes as defined in the Subsystem Performance Specification and Verification Plan of NASA/MSFC Contract NAS8-32259, dated October 28, 1976. The architectural and engineering firm of Smith, Hinchman and Grylls, Detroit, Michigan, acted in the capacity of the independent certification agency. The program calls for the development, fabrication, qualification and delivery of an air-liquid solar collector for solar heating, combined heating and cooling, and/or hot water systems.

  3. Solar Heating Systems with Evacuated Tubular Solar Collector

    DEFF Research Database (Denmark)

    Qin, Lin; Furbo, Simon

    1998-01-01

    Recently different designed evacuated tubular solar collectors were introduced on the market by different Chinese companies. In the present study, investigations on the performance of four different Chinese evacuated tubular collectors and of solar heating systems using these collectors were...... carried out, employing both laboratory test and theoretical calculations. The collectors were tested in a small solar domestic hot water (SDHW) system in a laboratory test facility under realistic conditions. The yearly thermal performance of solar heating systems with these evacuated tubular collectors......-plate collectors. For solar heating plants, the yearly energy output from these evacuated tubular collectors is about 40%-90% higher than the output from typical flat-plate collectors at an operation temperature of about 50°C....

  4. Behavior of a solar collector loop during stagnation

    DEFF Research Database (Denmark)

    Chen, Ziqian; Dragsted, Janne; Furbo, Simon

    2015-01-01

    A mathematical model simulating the emptying behavior of a pressurized solar collector loop with solar collectors with a good emptying behavior is developed and validated with measured data. The calculated results are in good agreement with the measured results. The developed simulation model...... is therefore suitable to determine the behavior of a solar collector loop during stagnation. A volume ratio R, which is the ratio of the volume of the vapour in the upper pipes of the solar collector loop during stagnation and the fluid content of solar collectors, is introduced to determine the mass...... of the collector fluid pushed into the expansion vessel during stagnation, Min. A correlation function for the mass Min and the volume ratio R for solar collector loops is obtained. The function can be used to determine a suitable size of expansion vessels for solar collector loops....

  5. Collectors of botanical specimens from the flora area mentioned in the Flora of Ethiopia and Eritrea

    DEFF Research Database (Denmark)

    Friis, Ib

    2009-01-01

    Information based on all available sources about full name, nationality, profession, area and period of collection, with whom they are known to have made joint collections, herbaria in which the collections have been deposited etc., for all collectors mentioned in vol. 1-7 of the Flora of Ethiopia...

  6. Electron beam simulations of a multi-stage depressed collector, including secondary and scattered electrons

    NARCIS (Netherlands)

    van der Geer, C. A. J.; Caplan, M.; Dionne, N.; van der Geer, S. B.; de Loos, M. J.; Verhoeven, A. G. A.; Valentini, M.; van der Wiel, M. J.; Urbanus, W. H.

    1998-01-01

    The Fusion FEM is the prototype of a high power, rapid-tunable mm-wave source, operating in the range 130-260 GHz (Urbanus, Nucl. Instr. and Meth. A 375 (1996) 401) [1]. The device is driven by a 2 MeV, 12 A DC electron beam. A decelerator and depressed collector will be mounted behind the mm-wave

  7. Theoretical and experimental investigation of Chinese evacuated tubular solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Lin Qin; Furbo, S.

    1999-06-01

    For many years evacuated tubular collectors have been marketed in Europe and the USA. These solar collectors are typically designed on the basis of the heat-pipe principle. Recently a number of Chinese firms started mass production of relatively cheap evacuated tubular solar collectors. The firms produce differently designed evacuated tubular solar collectors, e.g. with different absorbers and glass tube diameters with or without reflectors. As opposed to Europe, in Asia evacuated tubular solar collectors have reached such a low price level and such a high efficiency that in certain types of solar heating systems it has become attractive to use these high-efficient solar collectors instead of ordinary flat-plate collectors. At present the suitability of Chinese evacuated tubular solar collectors for different types of solar heating systems under Danish conditions are investigated at the Technical University of Denmark, DTU. The provisional results of these investigations, which are expected to be finished in the spring of 1999, are described in details in this document. The completed investigations indicate that the thermal performance of a small solar domestic hot water system can be improved if the evacuated tubular solar collector is used instead of a traditional flat-plate collector. However, the investigations indicate the price/performance-ratio of typical Danish small solar domestic hot water systems can not be improved by using evacuated tubular solar collectors instead of traditional flat-plate collector. Furthermore, the investigations indicate that it is not as important for the evacuated tubular solar collectors that the solar collectors are installed with `correct` orientation and tilt as it is for flat-plate collectors. The investigations also showed that it is an advantage for solar heating plants with high operation temperature to use high-efficient evacuated tubular solar collectors. (EHS)

  8. Detailed Modeling of Flat Plate Solar Collector with Vacuum Glazing

    OpenAIRE

    Viacheslav Shemelin; Tomas Matuska

    2017-01-01

    A theoretical analysis of flat plate solar collectors with a vacuum glazing is presented. Different configurations of the collector have been investigated by a detailed theoretical model based on a combined external and internal energy balance of the absorber. Performance characteristics for vacuum flat plate collector alternatives have been derived. Subsequently, annual energy gains have been evaluated for a selected variant and compared with state-of-the-art vacuum tube collectors. The resu...

  9. Solar Air Collectors: How Much Can You Save?

    Science.gov (United States)

    Newburn, J. D.

    1985-04-01

    A collector efficiency curve is used to determine the output of solar air collectors based on the testing of seven solar collectors sold in Iowa. In this application the solar heater is being used as a space heater for a house. The performance of the solar air heater was analyzed and an 8% savings in energy was achieved over a one year period using two 4 x 8 collectors in a typical house.

  10. Flat plate collector performance determined experimentally with a solar simulator

    Science.gov (United States)

    Vernon, R. W.; Simon, F. F.

    1974-01-01

    The NASA is constructing a new office building at Langley Research Center that will utilize solar energy for heating and cooling. A collector technology program being conducted at Lewis will provide the basis for selecting collectors for use at Langley. The technology program includes testing collectors in an indoor facility under simulated solar radiation. Tests have been conducted on five collectors to date and performance data are presented herein.

  11. Effect of thickness on the maximum potential drop of current collectors

    Science.gov (United States)

    Campillo-Robles, Jose Miguel; Artetxe, Xabier; del Teso Sánchez, Karmele

    2017-08-01

    The basic principle for achieving high-power capability on an electrochemical energy storage cell is minimizing the overall resistance. The resistance due to current collecting systems has not received sufficient attention in the past, presumably because it was not considered of significance for low-power batteries and supercapacitors. However, the necessity of high-power cells has reduced other sources of the inner resistance, and the current collector potential drop has become more important. Moreover, the miniaturization of energy storage devices could increase the ohmic loses in current collectors. In this work, we have developed an electrical model to assess the effect of the current collector thickness on the maximum potential drop. We have found that the thickness of current collectors is a critical parameter that can increase the maximum potential drop drastically. Indeed, the maximum potential drop of current collectors remains almost constant for thicknesses greater than 500 μm, but below this value, there is an inverse relationship between the maximum potential drop and the thickness. We have also analyzed the effect of the material and tab position in the maximum potential drop.

  12. Non-tracking solar energy collector system

    Science.gov (United States)

    Selcuk, M. K. (Inventor)

    1978-01-01

    A solar energy collector system is described characterized by an improved concentrator for directing incident rays of solar energy on parallel strip-like segments of a flatplate receiver. Individually mounted reflector modules of a common asymmetrical triangular cross-sectional configuration supported for independent orientation are asymmetric included with vee-trough concentrators for deflecting incident solar energy toward the receiver.

  13. A test program for solar collectors

    Science.gov (United States)

    1980-01-01

    Rigorous environmental and performance tests qualify solar collector for use in residential solar-energy systems. Testing over 7 month period examined pressurized effects, wind and snow loading, hail damage, solar and thermal degradation, effects of pollutants, efficiency, and outgassing. Test procedures and results are summarized in tables, graphs, and text.

  14. Hybrid thermoelectric solar collector design and analysis

    Science.gov (United States)

    Roberts, A. S., Jr.; Shaheen, K. E.

    1982-01-01

    A flat-plate solar collector is conceived where energy cascades through thermoelectric power modules generating direct-current electricity. The intent of this work was to choose a collector configuration and to perform a steady-state thermal performance assessment. A set of energy balance equations were written and solved numerically for the purpose of optimizing collector thermal and electrical performance. The collector design involves finned columns of thermoelectric modules imbedded in the absorber plate (hot junction) over a parallel array of vertical tubes. The thermoelectric power output is limited by the small hot-junction/cold-junction temperature difference which can be maintained under steady-state conditions. The electric power per unit tube pass area is found to have a maximum as a function of a geometric parameter, while electric power is maximized with respect to an electric resistance ratio. Although the electric power efficiency is small, results indicate that there is sufficient electric power production to drive a coolant circulator, suggesting the potential for a stand-alone system.

  15. Selective optical coatings for solar collectors

    Science.gov (United States)

    Lowery, J. R.

    1980-01-01

    For best performance, energy-absorbing surface of solar collector should be characterized by high ratio of solar absorptance to thermal emitance. Report on optical characteristics of several chemical treatments and electrodeposited coatings for metal solar-absorbing surfaces should interest designers and users of solar-energy systems. Moisture resistance of some coatings is also reported.

  16. Performance evaluation of a liquid solar collector

    Science.gov (United States)

    1979-01-01

    Report describes thermal performance and structural-load tests on commercial single glazed flat-plate solar collector with gross area of 63.5 sq ft that uses water as heat-transfer medium. Report documents test instrumentation and procedures and presents data as tables and graphs. Results are analyzed by standard data-reduction methods.

  17. 31 CFR 203.17 - Collector depositaries.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Collector depositaries. 203.17 Section 203.17 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) FISCAL SERVICE, DEPARTMENT OF THE TREASURY FINANCIAL MANAGEMENT SERVICE PAYMENT OF FEDERAL TAXES AND THE TREASURY...

  18. Design and Development of a Solar Thermal Collector with Single Axis Solar Tracking Mechanism

    Directory of Open Access Journals (Sweden)

    Theebhan Mogana

    2016-01-01

    Full Text Available The solar energy is a source of energy that is abundant in Malaysia and can be easily harvested. However, because of the rotation of the Earth about its axis, it is impossible to harvest the solar energy to the maximum capacity if the solar thermal collector is placed fix to a certain angle. In this research, a solar thermal dish with single axis solar tracking mechanism that will rotate the dish according to the position of the sun in the sky is designed and developed, so that more solar rays can be reflected to a focal point and solar thermal energy can be harvested from the focal point. Data were collected for different weather conditions and performance of the solar thermal collector with a solar tracker were studied and compared with stationary solar thermal collector.

  19. Design of an Energy System Based on Photovoltaic Thermal Collectors in the South of Algeria

    Directory of Open Access Journals (Sweden)

    K. Touafek

    2014-01-01

    Full Text Available The objective of this work is the design of a new energy system where the energy source will be provided by solar photovoltaic thermal (PV/T hybrid collectors. This system will be applied to a habitation in the region of Ghardaïa in the south of Algeria. The cold water reaches the thermal storage tank and then will be heated by the hybrid collector. The hot water will be used directly as sanitary water. The electric power produced by the hybrid collector will be used to charge the battery and will be delivered to the load (electrical appliances, lamps, etc.. Two types of loads are considered: a DC load and the other alternating current. The fans located adjacent to the radiators supplied with hot water will provide warm air to the house in winter.

  20. In situ built-up air collector with glass cover

    DEFF Research Database (Denmark)

    Kristiansen, Finn Harken; Engelmark, Jesper

    1998-01-01

    as an absorber. Efficiency and aair pressure drop were measured. The efficiency of the two air solar collectors was almost similar and at the same level as other corresponding air solar collectors. The air pressure drop was somewhat larger in the case of the solar collector where the air flows behind...

  1. Solar collector apparatus having increased energy rejection during stagnation

    Science.gov (United States)

    Moore, Stanley W.

    1983-07-12

    The disclosure relates to an active solar collector having increased energy rejection during stagnation. The collector's glazing is brought into substantial contact with absorber during stagnation to increase re-emittance and thereby to maintain lower temperatures when the collector is not in operation.

  2. Theoretical study on a solar collector loop during stagnation

    DEFF Research Database (Denmark)

    Chen, Ziqian; Dragsted, Janne; Furbo, Simon

    2010-01-01

    A mathematical model simulating the stagnation behavior of a pressurized solar collector loop with solar collectors with a good emptying behavior is developed. Based on the pre-pressure of the expansion vessel, the system filling pressure of the solar collector loop and the design of the solar co...

  3. 7 CFR 58.221 - Collectors and conveyors.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Collectors and conveyors. 58.221 Section 58.221....221 Collectors and conveyors. Collectors shall be made of stainless steel or equally noncorrosive... for cleaning and inspection. Conveyors shall be of stainless steel or equally corrosion resistant...

  4. THEORETICAL STUDY OF SOLAR COLLECTOR WITH MINI PARABOLIC CONCENTRATOR

    Directory of Open Access Journals (Sweden)

    I TABET

    2013-12-01

    Full Text Available In this paper, numerical modeling and simulation of the thermal behavior of a solar collector vacuum tube with a concentration has been done, the value of adding a system of concentration at the back of the collector and try to increase the amount of solar radiation incident on the collector  in order to obtain high temperatures compared to traditional flat plate collector  and improved their energy performance, this type of collector  being integrated into buildings for domestic hot water, air conditioning and for cooling.

  5. Thermal and optical efficiency investigation of a parabolic trough collector

    Directory of Open Access Journals (Sweden)

    C. Tzivanidis

    2015-09-01

    Full Text Available Solar energy utilization is a promising Renewable Energy source for covering a variety of energy needs of our society. This study presents the most well-known solar concentrating system, the parabolic trough collector, which is operating efficiently in high temperatures. The simulation tool of this analysis is the commercial software Solidworks which simulates complicated problems with an easy way using the finite elements method. A small parabolic trough collector model is designed and simulated for different operating conditions. The goal of this study is to predict the efficiency of this model and to analyze the heat transfer phenomena that take place. The efficiency curve is compared to a one dimensional numerical model in order to make a simple validation. Moreover, the temperature distribution in the absorber and inside the tube is presented while the heat flux distribution in the outer surface of the absorber is given. The heat convection coefficient inside the tube is calculated and compared with the theoretical one according to the literature. Also the angle efficiency modifier is calculated in order to predict the thermal and optical efficiency for different operating conditions. The final results show that the PTC model performs efficiently and all the calculations are validated.

  6. Theoretical study on a solar collector loop during stagnation

    DEFF Research Database (Denmark)

    Chen, Ziqian; Dragsted, Janne; Furbo, Simon

    A mathematical model simulating the stagnation behavior of a pressurized solar collector loop with solar collectors with a good emptying behavior is developed. Based on the pre-pressure of the expansion vessel, the system filling pressure of the solar collector loop and the design of the solar...... collector loop, the mass of the fluid flowing into the pressurized expansion vessel and the pressures at the top part and at the bottom part of the solar collector loop during stagnation for the solar collector loop are calculated. The theoretically calculated results are compared with experimental results....... There is a good agreement between calculations and measurements. The developed simulation model is therefore suitable to determine the behavior of solar collector loops during stagnation....

  7. Simulation of a solar collector array consisting of two types of solar collectors, with and without convection barrier

    DEFF Research Database (Denmark)

    Bava, Federico; Furbo, Simon; Perers, Bengt

    2015-01-01

    barrier, can be found on the Danish market. Depending on the temperature level at which the two types of collectors operate, one can perform better than the other. This project aimed to study the behavior of a 14 solar collector row made of these two different kinds of collectors, in order to optimize...... the composition of the row. Actual solar collectors available on the Danish market (models HT-SA and HT-A 35-10 manufactured by ARCON Solar A/S) were used for this analysis. To perform the study, a simulation model in TRNSYS was developed based on the Danish solar collector field in Braedstrup. A parametric...

  8. Self-tracking mechanisms for solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, K.

    1985-02-12

    A self-tracking mechanism for a solar collector comprises a plurality of sensor concentrators arranged side by side and a plurality of shape memory alloy coils each located at a position coincident with the focal line of the corresponding one of sensor concentrators. The shape memory alloy coil is treated so as to shrink into a memorized shape when heated. Each of a plurality of tension wires have one end connected to one end of the shape memory alloy coil and the other end wound up on a wire drum which is mounted on a drive shaft. A transfer mechanism is operatively connected to the drive shaft for transferring the rotation of the drive shaft to a rotatable main collector.

  9. Assessment of musculoskeletal load in refuse collectors

    Directory of Open Access Journals (Sweden)

    Zbigniew W. Jóźwiak

    2013-08-01

    Full Text Available Background: The aim of this work was to assess the load on the musculoskeletal system and its effects in the collectors of solid refuse. The rationale behind this study was to formulate proposals how to reduce excessive musculoskeletal load in this group of workers. Material and Methods: The study group comprised 15 refuse collectors aged 25 to 50 years. Data about the workplace characteristics and subjective complaints of workers were collected by the free interview and questionnaire. During the survey the photorecording of the workpostures, the distance and velocity by GPS recorders, measurements of forces necessary to move containers, energy expenditure (lung ventilation method, workload estimation using the Firstbeat system and REBA method and stadiometry were done. Results: The distance walked daily by the collectors operating in terms of 2 to 3 in urban areas was about 15 km, and in rural areas about 18 km. The most frequent musculoskeletal complaints concerned the feet (60% subjects, knees, wrists and shoulders (over 40% subjects. After work-shift all examined workers had vertebral column shorter by 10 to 14 mm (11.4 mm mean. Conclusions: The results of our study show that the refuse collectors are subjected to a very high physical load because of the work organization and the way it is performed. To avoid adverse health effects and overload it is necessary to undertake ergonomic interventions, involving training of workers to improve the way of their job performance, active and passive leisure, technical control of the equipment and refuse containers, as well as the renegotiation of contracts with clients, especially those concerning non-standard containers. Med Pr 2013;64(4:507–519

  10. High performance flat plate solar collector

    Science.gov (United States)

    Lansing, F. L.; Reynolds, R.

    1976-01-01

    The potential use of porous construction is presented to achieve efficient heat removal from a power producing solid and is applied to solar air heaters. Analytical solutions are given for the temperature distribution within a gas-cooled porous flat plate having its surface exposed to the sun's energy. The extracted thermal energy is calculated for two different types of plate transparency. Results show the great improvement in performance obtained with porous flat plate collectors as compared with analogous nonporous types.

  11. Protection of solar collector materials from UV

    Science.gov (United States)

    Castle, J. G., Jr.; Gause, R. L.; Whitaker, A.

    1978-01-01

    Certain plastic films, such as KAPTON, are known to be stable with excellent long-term aging characteristics under intense uv radiation. Our recent measurements of the optical transmission spectra of KAPTON films show an absorption edge in the blue and are interpreted in terms of an electronic excitation mechanism. The application of this type of film as covering for solar collectors is discussed in regard to the protection this strong uv absorption offers to the materials underneath.

  12. Theoretical study of fluidized solar collector performance

    Energy Technology Data Exchange (ETDEWEB)

    Adulla, S. H; Kassem, M A; El-Refaie, M. F. [Cairo University, Giza (Egypt)

    2000-07-01

    This work presents a proposed novel design aiming to increasing the absorber-to-fluid heat transfer coefficient. This is accomplished by introducing small solid particles inside the collector tubes. When the collector liquid flows, it causes the particles to be fluidized and spread in the tubes. The particles material, size and total number should be turned together with the fluid mass flow rate to keep the bed, or particle dispersion, length within the physical length of collector tubes. Thus, the particles would be confined in the collector only; and not carried over to other parts of the circulation loop. While moving, the particles erode the thermal boundary layer formed on the tube inner surface, hence increasing the heat transfer coefficient. [Spanish] Este articulo presenta un diseno novedoso destinado a aumentar el coeficiente de trasferencia de calor de absorbedor a fluido. Esto se lleva a cabo mediante la introduccion de particulas solidas dentro de los tubos del colector. Cuando fluye el liquido del colector origina que las particulas se fluidicen y se diseminen en los tubos. El material de las particulas, tamano y numero total debera de ser puesto en movimiento junto con el regimen de flujo de masa de fluido para mantener el lecho o la dispersion de particulas por largo tiempo dentro de la longitud fisica de los tubos de colector. De esta manera las particulas seran confinadas solamente en el colector y no seran arrastradas a otras partes del anillo de circulacion. Al moverse, las particulas erosionan la capa de frontera termica formada en la superficie interior del tubo, aumentando por tanto el coeficiente de transmision de calor.

  13. (AJST) EFFECT OF COLLECTOR, FROTHER AND DEPRESSANT ...

    African Journals Online (AJOL)

    The reagent dose rates were varied as follows: collector (10, 30, 50 and 80 g/t), frother (10, 20, and 30 g/t), and depressant (40, 60, and 100 g/t). The results showed that the addition of TDSC 39/R9004A frother (maximum recovery 72.49 % TCu with a concentrate grade of 29.5 % TCu at a dose rate of 30 g/t) to the scavenger ...

  14. Thin film absorber for a solar collector

    Science.gov (United States)

    Wilhelm, William G.

    1985-01-01

    This invention pertains to energy absorbers for solar collectors, and more particularly to high performance thin film absorbers. The solar collectors comprising the absorber of this invention overcome several problems seen in current systems, such as excessive hardware, high cost and unreliability. In the preferred form, the apparatus features a substantially rigid planar frame with a thin film window bonded to one planar side of the frame. An absorber in accordance with the present invention is comprised of two thin film layers that are sealed perimetrically. In a preferred embodiment, thin film layers are formed from a metal/plastic laminate. The layers define a fluid-tight planar envelope of large surface area to volume through which a heat transfer fluid flows. The absorber is bonded to the other planar side of the frame. The thin film construction of the absorber assures substantially full envelope wetting and thus good efficiency. The window and absorber films stress the frame adding to the overall strength of the collector.

  15. OFFSET - RAY TRACING OPTICAL ANALYSIS OF OFFSET SOLAR COLLECTOR FOR SPACE STATION SOLAR DYNAMIC POWER SYSTEM

    Science.gov (United States)

    Jefferies, K.

    1994-01-01

    OFFSET is a ray tracing computer code for optical analysis of a solar collector. The code models the flux distributions within the receiver cavity produced by reflections from the solar collector. It was developed to model the offset solar collector of the solar dynamic electric power system being developed for Space Station Freedom. OFFSET has been used to improve the understanding of the collector-receiver interface and to guide the efforts of NASA contractors also researching the optical components of the power system. The collector for Space Station Freedom consists of 19 hexagonal panels each containing 24 triangular, reflective facets. Current research is geared toward optimizing flux distribution inside the receiver via changes in collector design and receiver orientation. OFFSET offers many options for experimenting with the design of the system. The offset parabolic collector model configuration is determined by an input file of facet corner coordinates. The user may choose other configurations by changing this file, but to simulate collectors that have other than 19 groups of 24 triangular facets would require modification of the FORTRAN code. Each of the roughly 500 facets in the assembled collector may be independently aimed to smooth out, or tailor, the flux distribution on the receiver's wall. OFFSET simulates the effects of design changes such as in receiver aperture location, tilt angle, and collector facet contour. Unique features of OFFSET include: 1) equations developed to pseudo-randomly select ray originating sources on the Sun which appear evenly distributed and include solar limb darkening; 2) Cone-optics technique used to add surface specular error to the ray originating sources to determine the apparent ray sources of the reflected sun; 3) choice of facet reflective surface contour -- spherical, ideal parabolic, or toroidal; 4) Gaussian distributions of radial and tangential components of surface slope error added to the surface normals at

  16. Analysis and validation of a quasi-dynamic model for a solar collector field with flat plate collectors and parabolic trough collectors in series for district heating

    DEFF Research Database (Denmark)

    Tian, Zhiyong; Perers, Bengt; Furbo, Simon

    2018-01-01

    performance of the hybrid solar district heating plants is also presented. The measured and simulated results show that the integration of parabolic trough collectors in solar district heating plants can guarantee that the system produces hot water with relatively constant outlet temperature. The daily energy......A quasi-dynamic TRNSYS simulation model for a solar collector field with flat plate collectors and parabolic trough collectors in series was described and validated. A simplified method was implemented in TRNSYS in order to carry out long-term energy production analyses of the whole solar heating...... plant. The advantages of the model include faster computation with fewer resources, flexibility of different collector types in solar heating plant configuration and satisfactory accuracy in both dynamic and long-term analyses. In situ measurements were taken from a pilot solar heating plant with 5960 m...

  17. Hail resistance of solar collectors with tempered glass covers

    Science.gov (United States)

    Lof, G. O. G.; French, R. R.

    1980-01-01

    The resistance of solar collectors glazed with 3 mm of tempered glass to hailstones of up to 10 cm in diameter and 0.5 kg in weight which fell on Fort Collins, Colorado is discussed. Of the ten solar heating systems directly in the hailpath with tempered glass covers, seven were undamaged, two lost one collector panel each, and a 700-panel collector had seven broken covers, amounting to a total breakage of nine panels out of 956, approximately 1%. In addition, one system with nontempered glass covers suffered two glass punctures in a 26-panel collector. It is concluded that the risk of hail damage to commercial solar collectors glazed with 3-mm tempered glass is negligibly small, and greatly exceeded by the risk of hail damage to the roofs of buildings and automobiles or to fiberglass-reinforced polyester sheets used as collector glazings.

  18. Characterization of optical collectors for concentration photovoltaic applications

    Energy Technology Data Exchange (ETDEWEB)

    Anton, I.; Pachon, D.; Sala, G. [Ciudad Universitaria s/n, Inst. de Energia Solar, Madrid (Spain)

    2003-07-01

    The design and characterization of the collector of a photovoltaic concentrator system is commonly carried out for a given receiver, the optical parameters of the collector being linked to it. This paper, which has substantial tutorial content, deals with the characterization of collectors for concentrator photovoltaic systems, independently of any receiver, and providing the necessary parameters for the design of a system. This strategy allows the parameters related to the collector and the receiver, which are usually manufactured by different industries, to be totally separated. It also allows the optical collectors coming from non-photovoltaic industries to be evaluated. The information that the mirror and lens manufacturers should provide for a photovoltaic concentrator application can be summarized under three characteristics: overall optical efficiency; light distribution; and acceptance angle. Theory, equipment, and procedures to carry out the optical characterization of the collectors are explained. (Author)

  19. Evaluation of Test Method for Solar Collector Efficiency

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    on these efficiencies, an efficiency equation is determined by regression analysis. In the test method, there are no requirements on the ambient air temperature and the sky temperature. The paper will present an evaluation of the test method for a 12.5 m² flat plate solar collector panel from Arcon Solvarme A....../S. The solar collector panel investigated has 16 parallel connected horizontal absorber fins. CFD (Computational Fluid Dynamics) simulations, calculations with a solar collector simulation program SOLEFF (Rasmussen and Svendsen, 1996) and thermal experiments are carried out in the investigation......The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximated...

  20. Effect of dividing daylight in symmetric prismatic daylight collector

    Science.gov (United States)

    Yeh, Shih-Chuan; Lu, Ju-Lin; Cheng, Yu-Chin

    2017-04-01

    This paper presented a symmetric prismatic daylight collector to collect daylight for the natural light illumination system. We analyzed the characteristics of the emerging light when the parallel light beam illuminate on the horizontally placed symmetric prismatic daylight collector. The ratio of the relative intensities of collected daylight that emerging from each surface of the daylight collector shown that the ratio is varied with the incident angle during a day. The simulation of the emerging light of the daylight collector shown that the ratio of emerging light is varied with the tilted angle when sunshine illuminated on a symmetric prismatic daylight collector which was not placed horizontally. The integration of normalized intensity is also varied with the tilted angle. The symmetric prismatic daylight collector with the benefits of reducing glare and dividing intensity of incident daylight, it is applicable to using in the natural light illumination system and hybrid system for improving the efficiency of utilizing of solar energy.

  1. Mathematical Modeling of Dual Intake Transparent Transpired Solar Collector

    OpenAIRE

    Thomas Semenou; Rousse, Daniel R.; Brice Le Lostec; Hervé F. Nouanegue; Pierre-Luc Paradis

    2015-01-01

    Nowadays, in several types of commercial or institutional buildings, a significant rise of transpired solar collectors used to preheat the fresh air of the building can be observed. Nevertheless, when the air mass flow rate is low, the collector efficiency collapses and a large amount of energy remains unused. This paper presents a simple yet effective mathematical model of a transparent transpired solar collector (TTC) with dual intake in order to remove stagnation problems in the plenum and...

  2. The flooding of carbon collectors in Tatar fields

    Energy Technology Data Exchange (ETDEWEB)

    Kolevatova, A.N.; Solov' eva, V.N.; Suleymanov, E.I.

    1980-01-01

    The results of the development and flooding of oil deposits in carbon collectors are analyzed in this article. A short history of the field development is provided covering the period prior to, and since the flooding. It appears that the effectiveness of flooding carbon collectors in small fields in Tatariya was noted in only the Upin-Malevskiy deposits lining a relatively uniform and highly permeable collector.

  3. Evaluation of a Line-Concentrating Solar Collector

    Science.gov (United States)

    1982-01-01

    45-page report contains results of performance evaluation of line-concentrating solar collector. Collector employs parabolic trough to direct Sunlight to line along its focal axis, along which lies a black-chrome plated receiver tube covered by a glass tube containing still air. Reflective trough has aluminum-mirror surface covered with metallized acrylic film. Array of four collectors, positioned end to end was used for evaluation. Array was driven by single drive mechanism which was controlled by electronic tracking device.

  4. A Long Term Test of Differently Designed Evacuated Tubular Collectors

    DEFF Research Database (Denmark)

    Fan, Jianhua; Dragsted, Janne; Furbo, Simon

    2008-01-01

    and one direct flow ETC from Sunda Technolgoy Co. Ltd and one all-glass ETC with heat pipe from Exoheat AB. The collectors have been investigated side-by-side in an outdoor test facility for a long period. During the measurements, the operating conditions – such as weather conditions and temperature....... Further, the collector performances are compared for different times of the year and it is illustrated how the performance of the different collector types depends on weather conditions....

  5. Performance Analysis of Fractional-Order PID Controller for a Parabolic Distributed Solar Collector

    KAUST Repository

    Elmetennani, Shahrazed

    2017-09-01

    This paper studies the performance of a fractional-order proportional integral derivative (FOPID) controller designed for parabolic distributed solar collectors. The control problem addressed in concentrated solar collectors aims at forcing the produced heat to follow a desired reference despite the unevenly varying solar irradiance. In addition to the unpredictable variations of the energy source, the parabolic solar collectors are subject to inhomogeneous distributed efficiency parameters affecting the heat production. The FOPID controller is well known for its simplicity with better tuning flexibility along with robustness with respect to disturbances. Thus, we propose a control strategy based on FOPID to achieve the control objectives. First, the FOPID controller is designed based on a linear approximate model describing the system dynamics under nominal working conditions. Then, the FOPID gains and differentiation orders are optimally tuned in order to fulfill the robustness design specifications by solving a nonlinear optimization problem. Numerical simulations are carried out to evaluate the performance of the proposed FOPID controller. A comparison to the robust integer order PID is also provided. Robustness tests are performed for the nominal model to show the effectiveness of the FOPID. Furthermore, the proposed FOPID is numerically tested to control the distributed solar collector under real working conditions.

  6. Simulation Application for Optimization of Solar Collector Array

    Directory of Open Access Journals (Sweden)

    Igor Shesho*,

    2014-01-01

    Full Text Available Solar systems offer a comparatively low output density , so increasing the output always means a corresponding increase in the size of the collector area. Thus collector arrays are occasionally constructed (i.e. with different azimuth angles and/or slopes, which be imposed by the location and structure available to mount the collector. In this paper is developed simulation application for optimization for the solar collector array position and number of collectors in regard of maximum annual energy gain and thermal efficiency. It is analyzed solar collector array which has parallel and serial connected solar collectors with different tilt, orientation and thermal characteristics. Measurements are performed for determine the thermal performance of the system. Using the programming language INSEL it is developed simulation program for the analyzed system where optimization is done through parametric runs in the simulation program. Accent is given on the SE orientated collectors regarding their tilt and number, comparing two solutions-scenarios and the current system set situation of the in means of efficiency and total annual energy gain. The first scenario envisages a change of angle from 35 to 25 solar panels on the SE orientation, while the second scenario envisages retaining the existing angle of 35 and adding additional solar collector. Scenario 1 accounts for more than 13% energy gain on annual basis while Scenario 2 has 2% bigger thermal efficiency.

  7. Performances and yield assessment of glazed photovoltaic-thermal collectors

    OpenAIRE

    Dupeyrat, P.; Fortuin, S.; Kwiatkowski, G.; Baranzini, M.; Schumann, M.

    2012-01-01

    Photovoltaic-Thermal (PV-T) hybrid collectors are multi-energy components that convert solar energy into both electricity and heat. In this paper, the performances of a PV-T collector are investigated. The objective is not only the evaluation of the PV-T collector itself, but the evaluation of this component operating in a real energy system. For this purpose, experimental prototypes of PV-T collector were built, tested in an indoor sun simulator and finally installed and monitored at the EDF...

  8. EFFICIENCY AND LIFETIME OF SOLAR COLLECTORS FOR SOLAR HEATING PLANTS

    OpenAIRE

    Fan, Jianhua; Chen, Ziqian; Furbo, Simon; Perers, Bengt; Karlsson, Björn

    2009-01-01

    The 12.5 m² flat plate solar collector HT, today marketed by Arcon Solvarme A/S, has been used in solar heating plants in Scandinavia since 1983. The collector is designed to operate in a temperature interval between 40°C and 90°C. The efficiency of the collector has been strongly improved since it was introduced on the market. The paper will present the increase of the efficiency of the collector due to technical improvements since 1983. Further, measurements from the spring of 2009 of the e...

  9. High Performance Flat Plate Solar Thermal Collector Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Rockenbaugh, Caleb [National Renewable Energy Lab. (NREL), Golden, CO (United States); Dean, Jesse [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lovullo, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lisell, Lars [National Renewable Energy Lab. (NREL), Golden, CO (United States); Barker, Greg [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hanckock, Ed [National Renewable Energy Lab. (NREL), Golden, CO (United States); Norton, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-09-01

    This report was prepared for the General Services Administration by the National Renewable Energy Laboratory. The Honeycomb Solar Thermal Collector (HSTC) is a flat plate solar thermal collector that shows promising high efficiencies over a wide range of climate zones. The technical objectives of this study are to: 1) verify collector performance, 2) compare that performance to other market-available collectors, 3) verify overheat protection, and 4) analyze the economic performance of the HSTC both at the demonstration sites and across a matrix of climate zones and utility markets.

  10. Adaptive control of solar energy collector systems

    CERN Document Server

    Lemos, João M; Igreja, José M

    2014-01-01

    This book describes methods for adaptive control of distributed-collector solar fields: plants that collect solar energy and deliver it in thermal form. Controller design methods are presented that can overcome difficulties found in these type of plants:they are distributed-parameter systems, i.e., systems with dynamics that depend on space as well as time;their dynamics is nonlinear, with a bilinear structure;there is a significant level of uncertainty in plant knowledge.Adaptive methods form the focus of the text because of the degree of uncertainty in the knowledge of plant dynamics. Parts

  11. Line-focus concentrating collector program

    Science.gov (United States)

    Dugan, V. L.

    1980-01-01

    The Line-Focus Concentrating Collector Program has emphasized the development and dissemination of concentrating solar technology in which the reflected sunlight is focused onto a linear or line receiver. Although a number of different types of line-focus concentrators were developed, the parabolic trough has gained the widest acceptance and utilization within the industrial and applications sectors. The trough is best applied for application scenarios which require temperatures between 140 and 600 F. Another concept, the bowl, is investigated for applications which may require temperatures in the range between 600 and 1200 F. Current technology emphases are upon the reduction of system installation cost and the implementation of production oriented engineering.

  12. CMS DT Upgrade The Sector Collector Relocation

    CERN Document Server

    AUTHOR|(CDS)2079704

    2016-01-01

    The Sector Collector relocation is the first stage of the upgrade program for the Drift Tubes subdetector of the CMS experiment. It was accomplished during Long Shutdown 2013-2014, and consisted in the relocation of the second-level trigger and readout electronics from the experimental to the service cavern, relieving the environmental constraints and improving accessibility for maintenance and upgrade. Extending the electrical links would degrade reliability, so the information is converted to optical with a custom system capable of dealing with the DC-unbalanced data. Initially, present electronics are used, so optical-to-copper conversion has also been installed.

  13. A hybrid air conditioner driven by a hybrid solar collector

    Science.gov (United States)

    Al-Alili, Ali

    The objective of this thesis is to search for an efficient way of utilizing solar energy in air conditioning applications. The current solar Air Conditioners (A/C)s suffer from low Coefficient of Performance (COP) and performance degradation in hot and humid climates. By investigating the possible ways of utilizing solar energy in air conditioning applications, the bottlenecks in these approaches were identified. That resulted in proposing a novel system whose subsystem synergy led to a COP higher than unity. The proposed system was found to maintain indoor comfort at a higher COP compared to the most common solar A/Cs, especially under very hot and humid climate conditions. The novelty of the proposed A/C is to use a concentrating photovoltaic/thermal collector, which outputs thermal and electrical energy simultaneously, to drive a hybrid A/C. The performance of the hybrid A/C, which consists of a desiccant wheel, an enthalpy wheel, and a vapor compression cycle (VCC), was investigated experimentally. This work also explored the use of a new type of desiccant material, which can be regenerated with a low temperature heat source. The experimental results showed that the hybrid A/C is more effective than the standalone VCC in maintaining the indoor conditions within the comfort zone. Using the experimental data, the COP of the hybrid A/C driven by a hybrid solar collector was found to be at least double that of the current solar A/Cs. The innovative integration of its subsystems allows each subsystem to do what it can do best. That leads to lower energy consumption which helps reduce the peak electrical loads on electric utilities and reduces the consumer operating cost since less energy is purchased during the on peak periods and less solar collector area is needed. In order for the proposed A/C to become a real alternative to conventional systems, its performance and total cost were optimized using the experimentally validated model. The results showed that for an

  14. Simulation of a Solar Collector Array Consisting of two Types of Solar Collectors, with and Without Convection Barrier

    OpenAIRE

    Bava, Federico; Furbo, Simon; Perers, Bengt

    2015-01-01

    The installed area of solar collectors in solar heating fields is rapidly increasing in Denmark. In this scenario even relatively small performance improvements may lead to a large increase in the overall energy production. Both collectors with and without polymer foil, functioning as convection barrier, can be found on the Danish market. Depending on the temperature level at which the two types of collectors operate, one can perform better than the other. This project aimed to study the beha...

  15. Characterisation of shear stress distribution on a flat roof with solar collectors

    OpenAIRE

    Thiis, Thomas Kringlebotn; Ferreira, Almerindo D.; Molnar, Markus; Erichsen, Arnold

    2015-01-01

    i n the search for new renewable energy sources, photovoltaic systems and solar thermal collectors have become more common in buildings. With increased efficiency and demand for energy, solar power has also become exploitable at higher latitudes where snow is a major load on buildings. For flat roofs, one usually expects approximately 80% of the snow to be eroded off the roof surface. i nstalling solar panels would change this since the flow pattern and wind conditions o...

  16. Design features of vortex dust collectors

    Directory of Open Access Journals (Sweden)

    Puring Svetlana

    2017-01-01

    Full Text Available This article states that during the construction of industrial buildings it is necessary to provide engineering communications (including systems of supply and exhaust ventilation which ensure uninterrupted production, its technological and environmental safety. It is necessary to use cleaning devices to remove pollutants from ventilation emissions in local exhaust systems. As for devices for removing highly disperse non-sticky dust, it is possible to offer vortex dust collectors, the efficiency of which depends on the design and operating mode. A method is proposed to increase the efficiency of a vortex dust collector, to improve the quality of the purified air, and to reduce energy consumption during air purification by installing watering nozzles in primary and secondary air pipes made in the form of a Venturi tube. In consequence of multidirectional movement of dust particles and sprayed water, active coagulation of dust particles takes place, as a result of which the separation increases. Apart from that, watering dusty air flows leads to the formation of a liquid film on the inner surface of the separation chamber, which prevents dust particles from rebounding off the separation chamber and facilitates their capture and flushing into the collecting hopper

  17. How to select the best solar collector. Pt. 1. Comparative study of solar collector performance; Wo sich Spreu und Weizen trennen. T. 1. Kollektoren im energetischen Leistungsvergleich

    Energy Technology Data Exchange (ETDEWEB)

    Abrecht, S.; Kettner, C.; Meissner, R. [Paradigma Energie- und Umwelttechnik GmbH und Co.KG, Karlsbad (Germany)

    2008-06-15

    At higher operating temperatures, the results of solar collector with vacuum insulation differ from those with conventional thermal insulation, and tube collectors differ from flat plate collectors. In average insolation conditions (e.g. 450 W/m{sup 2}a at Wuerzburg), even the best flat plate collectors cannot compete with tube collectors at temperature gradients of 25 K and more from ambient temperature. From about 40 K, even the simplest tube collectors are better than flat plate collectors. These were the findings of internal studies carried out by Paradigma, a producer of solar systems. (orig.)

  18. Thermal performance of a hot-air solar collector

    Science.gov (United States)

    1978-01-01

    Report contains procedures and results of thermal-performance tests on double-glazed air solar collector. Four types of tests were carried out including thermal-efficiency and stagnation tests, collector time-constant tests to assess effects of transients, and incident-angle modifier tests. Data are presented in tables and as graphs and are discussed and analyzed.

  19. Determination of the Optimum Collector Angle for Composite Solar ...

    African Journals Online (AJOL)

    A model for predicting solar radiation available at any given time in the inhabited area in Ilorin was developed. From the equation developed, the optimum tilt angle of the collector due south was carried out. The optimum angle of tilt of the collector and the orientation are dependent on the month of the year and the location ...

  20. Preliminary design package for solar collector and solar pump

    Science.gov (United States)

    1978-01-01

    A solar-operated pump using an existing solar collector, for use on solar heating and cooling and hot water systems is described. Preliminary design criteria of the collector and solar-powered pump is given including: design drawings, verification plans, and hazard analysis.

  1. Advances in design of air-heating collectors

    CSIR Research Space (South Africa)

    Johannsen, A

    1982-11-01

    Full Text Available Principles of the operation of air-heating collectors are discussed. The fundamental differences between the design principles of air-heating as opposed to water-heating collectors are highlighted. The main requirement is the transfer of heat from...

  2. Solar collector design with respect to moisture problems

    DEFF Research Database (Denmark)

    Holck, Ole; Svendsen, Svend; Brunold, Stefan

    2003-01-01

    more ventilation openings should be made and what influence the insulation material has. Guidelines for collector designers are proposed. The design guidelines provide some suggestions to be considered during the design of solar collectors.The work was carried out within the framework of the working...

  3. ANALYSIS AND MODELING OF SOLAR EVAPORATOR-COLLECTOR

    Directory of Open Access Journals (Sweden)

    Zakaria Mohd. Amin

    2015-11-01

    Full Text Available Solar energy is considered a sustainable resource that poses little to no harmful effects on the environment. The performance of a solar system depends to a great extent on the collector used for the conversion of solar radiant energy to thermal energy. A solar evaporator-collector (SEC is basically an unglazed flat plate collector where refrigerants, such as R134a is used as the working fluid. As the operating temperature of the SEC is very low, it utilizes both solar irradiation and ambient energy leading to a much higher efficiency than the conventional collectors. This capability of SECs to utilize ambient energy also enables the system to operate at night. This type of collector can be locally made and is relatively much cheaper than the conventional collector.   At the National University of Singapore, the evaporator-collector was integrated to a heat pump and the performance was investigated for several thermal applications: (i water heating, (ii drying and (iii desalination. A 2-dimensional transient mathematical model of this system was developed and validated by experimental data. The present study provides a comprehensive study of performance. KEYWORDS: heat pump; evaporator-collector.

  4. Weathering of a flat-plate solar collector

    Science.gov (United States)

    1980-01-01

    Report contains performance evaluation of flat-plate liquid solar collector after 14-months of natural weathering. Collector efficiency was calculated and plotted as function of inlet liquid temperature. Measurements were made of ambient temperature, inlet and outlet temperatures, differential temperature and pressure, liquid flow rate, insolation, and windspeed.

  5. A tool for standardized collector performance calculations including PVT

    DEFF Research Database (Denmark)

    Perers, Bengt; Kovacs, Peter; Olsson, Marcus

    2012-01-01

    in Europe. The collector parameters used as input in the tool are compiled from tests according to EN12975, without any intermediate conversions. The main target group for this tool is test institutes and certification bodies that are intended to use it for conversion of collector model parameters (derived...

  6. Thermal performances of vertical hybrid PV/T air collector

    Science.gov (United States)

    Tabet, I.; Touafek, K.; Bellel, N.; Khelifa, A.

    2016-11-01

    In this work, numerical analyses and the experimental validation of the thermal behavior of a vertical photovoltaic thermal air collector are investigated. The thermal model is developed using the energy balance equations of the PV/T air collector. Experimental tests are conducted to validate our mathematical model. The tests are performed in the southern Algerian region (Ghardaïa) under clear sky conditions. The prototype of the PV/T air collector is vertically erected and south oriented. The absorber upper plate temperature, glass cover temperature, air temperature in the inlet and outlet of the collector, ambient temperature, wind speed, and solar radiation are measured. The efficiency of the collector increases with increase in mass flow of air, but the increase in mass flow of air reduces the temperature of the system. The increase in efficiency of the PV/T air collector is due to the increase in the number of fins added. In the experiments, the air temperature difference between the inlet and the outlet of the PV/T air collector reaches 10 ° C on November 21, 2014, the interval time is between 10:00 and 14:00, and the temperature of the upper plate reaches 45 ° C at noon. The mathematical model describing the dynamic behavior of the typical PV/T air collector is evaluated by calculating the root mean square error and mean absolute percentage error. A good agreement between the experiment and the simulation results is obtained.

  7. MINICHANNEL-TUBE SOLAR THERMAL COLLECTORS FOR LOW TO MEDIUM TEMPERATURE APPLICATIONS

    OpenAIRE

    Duong, Thuc

    2015-01-01

    Novel minichannel-tube solar thermal collectors for low to medium temperature applications are introduced. Two types of minichannel solar thermal collectors are analyzed experimentally: aluminum minichannel solar collector for low temperature applications, and copper minichannel solar collector for low to medium temperature applications.The aluminum minichannel solar collector has been tested for over a year alongside a conventional copper flat-plate solar collector of similar dimensions as t...

  8. Analysis of a solar collector field water flow network

    Science.gov (United States)

    Rohde, J. E.; Knoll, R. H.

    1976-01-01

    A number of methods are presented for minimizing the water flow variation in the solar collector field for the Solar Building Test Facility at the Langley Research Center. The solar collector field investigated consisted of collector panels connected in parallel between inlet and exit collector manifolds to form 12 rows. The rows were in turn connected in parallel between the main inlet and exit field manifolds to complete the field. The various solutions considered included various size manifolds, manifold area change, different locations for the inlets and exits to the manifolds, and orifices or flow control valves. Calculations showed that flow variations of less than 5 percent were obtainable both inside a row between solar collector panels and between various rows.

  9. Test results, Industrial Solar Technology parabolic trough solar collector

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, V.E. [EG and G MSI, Albuquerque, NM (United States); Evans, L.R.; Matthews, C.W. [Sandia National Labs., Albuquerque, NM (United States)

    1995-11-01

    Sandia National Laboratories and Industrial Solar Technology are cost-sharing development of advanced parabolic trough technology. As part of this effort, several configurations of an IST solar collector were tested to determine the collector efficiency and thermal losses with black chrome and black nickel receiver selective coatings, combined with aluminized film and silver film reflectors, using standard Pyrex{reg_sign} and anti-reflective coated Pyrex{reg_sign} glass receiver envelopes. The development effort has been successful, producing an advanced collector with 77% optical efficiency, using silver-film reflectors, a black nickel receiver coating, and a solgel anti-reflective glass receiver envelope. For each receiver configuration, performance equations were empirically derived relating collector efficiency and thermal losses to the operating temperature. Finally, equations were derived showing collector performance as a function of input insolation value, incident angle, and operating temperature.

  10. Detailed Modeling of Flat Plate Solar Collector with Vacuum Glazing

    Directory of Open Access Journals (Sweden)

    Viacheslav Shemelin

    2017-01-01

    Full Text Available A theoretical analysis of flat plate solar collectors with a vacuum glazing is presented. Different configurations of the collector have been investigated by a detailed theoretical model based on a combined external and internal energy balance of the absorber. Performance characteristics for vacuum flat plate collector alternatives have been derived. Subsequently, annual energy gains have been evaluated for a selected variant and compared with state-of-the-art vacuum tube collectors. The results of modeling indicate that, in the case of using advanced vacuum glazing with optimized low-emissivity coating (emissivity 0.20, solar transmittance 0.85, it is possible to achieve efficiency parameters similar to or even better than vacuum tube collectors. The design presented in this paper can be considered promising for the extension of the applicability range of FPC and could be used in applications, which require low-to-medium temperature level.

  11. Optical performance of fluorescent collectors integrated with microlens arrays

    Science.gov (United States)

    Damrongsak, Pattareeya; Locharoenrat, Kitsakorn

    2017-09-01

    Fluorescent collectors have been considered for being used as a light concentrator in photovoltaic applications. It is able to replace the expensive area of solar cells in order to minimize the energy cost. In this study, fluorescent collectors integrated with microlens arrays were developed in order to improve the collection efficiency. Fluorescent collectors were prepared by casting an epoxy resin solution containing Rhodamine 6G dye in the polydimethylsiloxane master mold. Polydimethylsiloxane-based microlens arrays with actual diameters of 804.06-1008.02 µm were fabricated using a replica molding technique. The microlens arrays were then integrated with the fluorescent collectors with various dye concentrations from 2.5  ×  10-4 to 4.5  ×  10-4 Molar. Experimental results were demonstrated that the implementation of polydimethylsiloxane microlens arrays on the top of fluorescent collectors was improved for both light absorption and fluorescent intensity.

  12. A solar air collector with integrated latent heat thermal storage

    Science.gov (United States)

    Charvat, Pavel; Ostry, Milan; Mauder, Tomas; Klimes, Lubomir

    2012-04-01

    Simulations of the behaviour of a solar air collector with integrated latent heat thermal storage were performed. The model of the collector was created with the use of coupling between TRNSYS 17 and MATLAB. Latent heat storage (Phase Change Material - PCM) was integrated with the solar absorber. The model of the latent heat storage absorber was created in MATLAB and the model of the solar air collector itself was created in TRNSYS with the use of TYPE 56. The model of the latent heat storage absorber allows specification of the PCM properties as well as other parameters. The simulated air collector was the front and back pass collector with the absorber in the middle of the air cavity. Two variants were considered for comparison; the light-weight absorber made of sheet metal and the heat-storage absorber with the PCM. Simulations were performed for the climatic conditions of the Czech Republic (using TMY weather data).

  13. TaxCollector: Modifying Current 16S rRNA Databases for the Rapid Classification at Six Taxonomic Levels

    Directory of Open Access Journals (Sweden)

    Eric W. Triplett

    2010-07-01

    Full Text Available The high level of conservation of 16S ribosomal RNA gene (16S rRNA in all Prokaryotes makes this gene an ideal tool for the rapid identification and classification of these microorganisms. Databases such as the Ribosomal Database Project II (RDP-II and the Greengenes Project offer access to sets of ribosomal RNA sequence databases useful in identification of microbes in a culture-independent analysis of microbial communities. However, these databases do not contain all of the taxonomic levels attached to the published names of the bacterial and archaeal sequences. TaxCollector is a set of scripts developed in Python language that attaches taxonomic information to all 16S rRNA sequences in the RDP-II and Greengenes databases. These modified databases are referred to as TaxCollector databases, which when used in conjunction with BLAST allow for rapid classification of sequences from any environmental or clinical source at six different taxonomic levels, from domain to species. The TaxCollector database prepared from the RDP-II database is an important component of a new 16S rRNA pipeline called PANGEA. The usefulness of TaxCollector databases is demonstrated with two very different datasets obtained using samples from a clinical setting and an agricultural soil. The six TaxCollector scripts are freely available on http://taxcollector.sourceforge.net and on http://www.microgator.org.

  14. Study of Cylindrical Honeycomb Solar Collector

    Directory of Open Access Journals (Sweden)

    Atish Mozumder

    2014-01-01

    Full Text Available We present the results of our investigation on cylindrical honeycomb solar collector. The honeycomb has been fabricated with transparent cellulose triacetate polymer sheets. Insulation characteristics of the honeycomb were studied by varying the separation between the honeycomb and the absorber plate. The optimal value of the separation was found to be 3.3 mm for which the heat transfer coefficient is 3.06 W m−2 K−1. This supports result of previous similar experiments. Further we test the honeycomb through a field experiment conducted in Delhi (28.6°N, 77°E and found that when the incident angle of the solar radiation is within 20° then the performance of the system with the honeycomb is better than the one without the honeycomb.

  15. Use of membrane collectors in electrostatic precipitators.

    Science.gov (United States)

    Bayless, D J; Pasic, H; Alam, M K; Shi, L; Haynes, B; Cochran, J; Khan, W

    2001-10-01

    Membrane collection surfaces, developed and patented by researchers at Ohio University, were used to replace steel plates in a dry electrostatic precipitator (ESP). Such replacement facilitates tension-based rapping, which shears the adhered particle layer from the collector surface more effectively than hammer-based rapping. Tests were performed to measure the collection efficiency of the membranes and to quantify the potential improvements of this novel cleaning technique with respect to re-entrainment. Results indicate that even semiconductor materials (e.g., carbon fibers) collect ash nearly as efficiently as steel plates, potentially indicating that collection surface resistivity is primarily dictated by the accumulated ash layer and not by the underlying plate conductivity. In addition, virtually all sheared particles separated from the collecting membranes fell within the boundary layer of the membrane, indicating extremely low potential for re-entrainment.

  16. Alignment method for solar collector arrays

    Science.gov (United States)

    Driver, Jr., Richard B

    2012-10-23

    The present invention is directed to an improved method for establishing camera fixture location for aligning mirrors on a solar collector array (SCA) comprising multiple mirror modules. The method aligns the mirrors on a module by comparing the location of the receiver image in photographs with the predicted theoretical receiver image location. To accurately align an entire SCA, a common reference is used for all of the individual module images within the SCA. The improved method can use relative pixel location information in digital photographs along with alignment fixture inclinometer data to calculate relative locations of the fixture between modules. The absolute locations are determined by minimizing alignment asymmetry for the SCA. The method inherently aligns all of the mirrors in an SCA to the receiver, even with receiver position and module-to-module alignment errors.

  17. Genesis Solar Wind Array Collector Cataloging Status

    Science.gov (United States)

    Burkett, P.J.; Rodriguez, M.C.; Calaway, M.C.; Allton, J.H.

    2009-01-01

    Genesis solar wind array collectors were fractured upon landing hard in Utah in 2004. The fragments were retrieved from the damaged canister, imaged, repackaged and shipped to the Johnson Space Center curatorial facility [1]. As of January 2009, the collection consists of 3460 samples. Of these, 442 are comprised into "multiple" sample groupings, either affixed to adhesive paper (177) or collected in jars (17), culture trays (87), or sets of polystyrene vials (161). A focused characterization task was initiated in May 2008 to document the largest samples in the collection. The task consisted of two goals: to document sapphire based fragments greater than 2 cm in one dimension, and to document silicon based fragments greater than 1 cm in one direction.

  18. Glass heat pipe evacuated tube solar collector

    Science.gov (United States)

    McConnell, Robert D.; Vansant, James H.

    1984-01-01

    A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.

  19. Analysis of WWER 1000 collector cracking mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Matocha, K.; Wozniak, J. [Vitkovice J.S.C., Ostrava (Switzerland)

    1997-12-31

    The presentation reviews the large experimental program, started in 1993 in Vitkovice, where the main aim was: (1) a detailed study of strain and thermal ageing, dissolved oxygen content and temperature on subcritical crack growth in 10NiMo8.5 (10GN2MFA) steel, (2) a detailed study of the effect of high temperature water and tube expansion technology on fracture behaviour of ligaments between holes for heat exchange tubes, and (3) a detailed study of the effect of drilling, tube expansion technology and heat treatment on residual stresses on the surface of holes for heat exchange tubes. The aim of all these investigations was to find a dominant damage mechanism responsible for collector cracking to be able to judge the efficiency of implemented modifications and suggested countermeasures and to answer a very important question whether proper operation conditions (mainly water chemistry) make the operation of steam generators made in Vitcovice safe throughout the planned lifetime. 10 refs.

  20. EXPERIMENTAL RESEARCH OF THE INFLUENCE OF VARIOUS TYPES OF SOLAR COLLECTORS FOR PERFORMANCE SOLAR DESALINATION PLANT

    Directory of Open Access Journals (Sweden)

    Rakhmatulin I.R.

    2014-04-01

    Full Text Available The article discusses the possibility of using renewable energy for water purification. Results of analysis of a preferred energy source for a water purification using installed in places where fresh water shortages and a lack of electrical energy. The possibility of desalination of salt water using solar energy for regions with temperate climate. Presented desalination plant working on energy vacuum solar collectors, principles of action developed by the desalination plant. The experimental results of a constructed distiller when working with vacuum glass tubes and vacuum tubes with copper core inside. Conclusions about the possibility of using solar collectors for water desalination, are tips and tricks to improve the performance of solar desalination plant.

  1. PERFORMANCE EVALUATION OF SOLAR COLLECTORS USING A SOLAR SIMULATOR

    Directory of Open Access Journals (Sweden)

    M. Norhafana

    2015-11-01

    Full Text Available Solar water heating systems is one of the applications of solar energy. One of the components of a solar water heating system is a solar collector that consists of an absorber. The performance of the solar water heating system depends on the absorber in the solar collector. In countries with unsuitable weather conditions, the indoor testing of solar collectors with the use of a solar simulator is preferred. Thus, this study is conducted to use a multilayered absorber in the solar collector of a solar water heating system as well as to evaluate the performance of the solar collector in terms of useful heat of the multilayered absorber using the multidirectional ability of a solar simulator at several values of solar radiation. It is operated at three variables of solar radiation of 400 W/m2, 550 W/m2 and 700 W/m2 and using three different positions of angles at 0º, 45º and 90º. The results show that the multilayer absorber in the solar collector is only able to best adapt at 45° of solar simulator with different values of radiation intensity. At this angle the maximum values of useful heat and temperature difference are achieved. KEYWORDS: solar water heating system; solar collector; multilayered absorber; solar simulator; solar radiation 

  2. Evaluation of heat transfer enhancement in air-heating collectors

    Energy Technology Data Exchange (ETDEWEB)

    Mattox, D. L.

    1979-06-01

    The present research effort was initiated for the purpose of increasing the thermal efficiency of air heating solar collectors through identification and development of optimum design and operation criteria for solar absorber-to-air heat exchangers. Initially this effort took the form of a solar collector systems analysis to evaluate the impact of various techniques for enhancing the heat transfer between the absorber and air stream on overall thermal performance of the entire solar collector. This systems analysis resulted in the selection of solar collector designs providing ducted cooling air on the absorber shaded side as a base line. A transient heat transfer analysis of a complete solar air heating collector was used to demonstrate that an optimum absorber-to-air heat exchanger design could be provided with several interrupted fin configurations. Additional analyses were performed to establish that the maximum solar collector thermal performance to required pumping power was realized for a Reynolds number range of 1000 to 2000. This Reynolds number range was used to establish a theoretical design limit curve for maximum thermal performance versus required pumping power for all interrupted fin designs as published in the open literature. Heat and momentum transfer empirical relationships were defined for scaling the state-of-the-art high conductance fin designs identified from a compact configuration to the less compact designs needed for solar collectors.

  3. A high performance porous flat-plate solar collector

    Science.gov (United States)

    Lansing, F. L.; Clarke, V.; Reynolds, R.

    1979-01-01

    A solar collector employing a porous matrix as a solar absorber and heat exchanger is presented and its application in solar air heaters is discussed. The collector is composed of a metallic matrix with a porous surface which acts as a large set of cavity radiators; cold air flows through the matrix plate and exchanges heat with the thermally stratified layers of the matrix. A steady-state thermal analysis of the collector is used to determine collector temperature distributions for the cases of an opaque surface matrix with total absorption of solar energy at the surface, and a diathermanous matrix with successive solar energy absorption at each depth. The theoretical performance of the porous flat plate collector is shown to exceed greatly that of a solid flat plate collector using air as the working medium for any given set of operational conditions. An experimental collector constructed using commercially available, low cost steel wool as the matrix has been found to have thermal efficiencies from 73 to 86%.

  4. Annual measured and simulated thermal performance analysis of a hybrid solar district heating plant with flat plate collectors and parabolic trough collectors in series

    DEFF Research Database (Denmark)

    Tian, Zhiyong; Perers, Bengt; Furbo, Simon

    2017-01-01

    the district heating network to about 70 °C and then the parabolic trough collectors would heat the preheated water to the required supply temperature of the district heating network. Annual measured and simulated thermal performances of both the parabolic trough collector field and the flat plate collector...... in large solar heating plants for a district heating network, a hybrid solar collector field with 5960 m2 flat plate collectors and 4039 m2 parabolic trough collectors in series was constructed in Taars, Denmark. The design principle is that the flat plate collectors preheat the return water from...... field are presented in this paper. The thermal performance of both collector fields with weather data of a Design Reference Year was simulated to have a whole understanding of the application of both collectors under Danish climate conditions as well. These results not only can provide a design basis...

  5. sources

    Directory of Open Access Journals (Sweden)

    Shu-Yin Chiang

    2002-01-01

    Full Text Available In this paper, we study the simplified models of the ATM (Asynchronous Transfer Mode multiplexer network with Bernoulli random traffic sources. Based on the model, the performance measures are analyzed by the different output service schemes.

  6. Mathematical modelling of unglazed solar collectors under extreme operating conditions

    DEFF Research Database (Denmark)

    Bunea, M.; Perers, Bengt; Eicher, S.

    2015-01-01

    average temperature levels at the evaporator. Simulation of these systems requires a collector model that can take into account operation at very low temperatures (below freezing) and under various weather conditions, particularly operation without solar irradiation.A solar collector mathematical model...... was found due to the condensation phenomenon and up to 40% due to frost under no solar irradiation. This work also points out the influence of the operating conditions on the collector's characteristics.Based on experiments carried out at a test facility, every heat flux on the absorber was separately...

  7. Performance of solar collectors under low temperature conditions

    DEFF Research Database (Denmark)

    Bunea, Mircea; Eicher, Sara; Hildbrand, Catherine

    evaluated and results compared to experimental measurements. A mathematical model is also under development to include, in addition to the condensation phenomena, the frost, the rain and the long-wave radiation gains/losses on the rear of the solar collector. While the potential gain from rain was estimated......The performance of four solar thermal collectors (flat plate, evacuated tube, unglazed with rear insulation and unglazed without rear insulation) was experimentally measured and simulated for temperatures below ambient. The influence of several parameters (e.g. collector inlet temperature, air...

  8. Fuzzy Approximate Model for Distributed Thermal Solar Collectors Control

    KAUST Repository

    Elmetennani, Shahrazed

    2014-07-01

    This paper deals with the problem of controlling concentrated solar collectors where the objective consists of making the outlet temperature of the collector tracking a desired reference. The performance of the novel approximate model based on fuzzy theory, which has been introduced by the authors in [1], is evaluated comparing to other methods in the literature. The proposed approximation is a low order state representation derived from the physical distributed model. It reproduces the temperature transfer dynamics through the collectors accurately and allows the simplification of the control design. Simulation results show interesting performance of the proposed controller.

  9. FLOW DISTRIBUTION IN A SOLAR COLLECTOR PANEL WITH HORIZONTAL FINS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    2005-01-01

    The objective of this work is to theoretically and experimentally investigate the flow and temperature distribution in a solar collector panel with an absorber consisting of horizontal fins. Fluid flow and heat transfer in the collector panel are studied by means of computational fluid dynamics...... (CFD) calculations. Further, experimental investigations of a 12.5 m² solar collector panel with 16 parallel connected horizontal fins are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the backside of the absorber tubes. The measured...

  10. Calculating the Solar Energy of a Flat Plate Collector

    Directory of Open Access Journals (Sweden)

    Ariane Rosario

    2014-09-01

    Full Text Available The amount of solar energy that could be obtained by a flat plate solar collector of one square meter dimension is calculated in three different locations: Tampa FL, Fairbanks AL, and Pontianak Indonesia, considering the varying sunset time for each day of the year. The results show that if the collectors are placed near the equator, more total energy could be obtained. In fact, by placing a solar collector in Pontianak, Indonesia 12.42% more solar energy can be obtained than by placing it in Tampa and 96.9% more solar energy than Alaska.

  11. Analysis of a high-performance tubular solar collector

    Science.gov (United States)

    Lansing, F. L.; Yung, C. S.

    1981-01-01

    This article analyzes the thermal performance of a new vacuum tube solar collector. The assumptions and mathematical modeling are presented. The problem is reduced to the formulation of two simultaneous linear differential equations characterizing the collector thermal behavior. After applying the boundary conditions, a general solution is obtained which is found similar to the general Hottel, Whillier and Bliss form, but with a complex flow factor. The details of the two-dimensional thermal model of the solar collector at steady state is also presented to include the computer simulation and the performance parameterization. Comparison of the simulated performance with the manufacturer's test data showed good agreement at wide ranges of operating conditions.

  12. Sources

    OpenAIRE

    2015-01-01

    Sources Fondation Pablo Iglesias. Alcala de Henares. Sections : Archives privées de Manuel ArijaArchives extérieuresArchives FNJS de EspañaPrensa Archives Générales de l’Administration. Alcala de Henares. Sections : Opposition au franquismeSig. 653 Sig TOP 82/68.103-68.602.Índice de las cartas colectivas, Relaciones, Cartas al Ministro de Información de Marzo de 1965. c.662. Sources cinématographiques Filmothèque Nationale d’Espagne.NO.DO. N° 1157C. 08/03/1965.aguirre Javier, Blanco vertical....

  13. Measurements and Calculations of the Effects of Distortions in the Collector Surface on Efficiencies of Umbrella-Type Solar Collectors

    Science.gov (United States)

    Bond, Victor R.

    1961-01-01

    The meridional tensions along the ribs in a Mylar-covered umbrella-type solar collector produce a distortion in the reflecting surface that is detrimental to the image in the focal plane. The investigation reported herein was made to obtain measured and calculated geometric efficiencies of umbrella-type collectors as affected by these surface distortions. These studies show that if the tension transverse to the ribs is increased relative to the meridional tensions, the distortion is reduced and higher efficiencies can be attained, and if the transverse tension is small, the number of ribs in the collector must be increased for higher efficiencies.

  14. Performance of wood in a do-it-yourself solar collector

    Science.gov (United States)

    G. E. Sherwood; W. A. Gatz

    1979-01-01

    Six variations of a do-it-yourself solar collector design were constructed and exposed under stagnation conditions for 1 year; collectors were basically closed boxes without air circulation. Temperature in each collector was recorded throughout the test period and the effect of these temperatures on the wood framing and plywood in the collectors was estimated...

  15. Solar Thermal AIR Collector Based on New Type Selective Coating

    National Research Council Canada - National Science Library

    Musiy, R.Y; Midyana, G.G; Makitra, R.G; Vasyutin, J.M; Khovanets, G.I; Zaborowskiy, A.B

    2014-01-01

    Based on the best for optical performance and selective coating solar thermal air collector, which operates by solar power on the principle of simultaneous ventilation and heating facilities, is designed...

  16. Mathematical Modeling of Dual Intake Transparent Transpired Solar Collector

    Directory of Open Access Journals (Sweden)

    Thomas Semenou

    2015-01-01

    Full Text Available Nowadays, in several types of commercial or institutional buildings, a significant rise of transpired solar collectors used to preheat the fresh air of the building can be observed. Nevertheless, when the air mass flow rate is low, the collector efficiency collapses and a large amount of energy remains unused. This paper presents a simple yet effective mathematical model of a transparent transpired solar collector (TTC with dual intake in order to remove stagnation problems in the plenum and ensure a better thermal efficiency and more heat recovery. A thermal model and a pressure loss model were developed. Then, the combined model was validated with experimental data from the Solar Rating and Certification Corporation (SRCC. The results show that the collector efficiency can be up to 70% and even 80% regardless of operating conditions. The temperature gain is able to reach 20°K when the solar irradiation is high.

  17. Thermal Performance of an Annealed Pyrolytic Graphite Solar Collector

    Science.gov (United States)

    Jaworske, Donald A.; Hornacek, Jennifer

    2002-01-01

    A solar collector having the combined properties of high solar absorptance, low infrared emittance, and high thermal conductivity is needed for applications where solar energy is to be absorbed and transported for use in minisatellites. Such a solar collector may be used with a low temperature differential heat engine to provide power or with a thermal bus for thermal switching applications. One concept being considered for the solar collector is an Al2O3 cermet coating applied to a thermal conductivity enhanced polished aluminum substrate. The cermet coating provides high solar absorptance and the polished aluminum provides low infrared emittance. Annealed pyrolytic graphite embedded in the aluminum substrate provides enhanced thermal conductivity. The as-measured thermal performance of an annealed pyrolytic graphite thermal conductivity enhanced polished aluminum solar collector, coated with a cermet coating, will be presented.

  18. Theoretical flow investigations of an all glass evacuated tubular collector

    DEFF Research Database (Denmark)

    Shah, Louise Jivan; Furbo, Simon

    2007-01-01

    Heat transfer and flow structures inside all glass evacuated tubular collectors for different operating conditions are investigated by means of computational fluid dynamics. The investigations are based on a collector design with horizontal tubes connected to a vertical 14 manifold channel. Three...... different tube lengths varying from 0.59 in to 1.47 in have been modelled with five different inlet mass flow rates varying from 0.05 kg/min to 10 kg/min with a constant inlet temperature of 333 K. Under these operating conditions the results showed that: the collector with the shortest tube length achieved...... the highest efficiency, the optimal inlet flow rate was around 0.4-1 kg/min, the flow structures in the glass tubes were relatively uninfluenced by the inlet flow rate, Generally, the results showed only small variations in the efficiencies. This indicates that the collector design is well working for most...

  19. Glycol/water evacuated-tube solar collector

    Science.gov (United States)

    1980-01-01

    Report describes performance of 8 tube and 10 tube commercially produced solar collectors. Tests include thermal efficiency, time constant for temperature drop after solar flux is cut, change in efficiency with Sun angle, and temperature rise if circulation is stopped.

  20. Indoor tests of the concentric-tube solar collector

    Science.gov (United States)

    1980-01-01

    Report describes performance tests on 12-tube, liquid-filled collector. Thermal efficiency, change in efficiency with sun position, and time constant for temperature drop after solar flux is cut are described.

  1. Final report on the concentric-tube solar collector

    Science.gov (United States)

    Parker, J. C.

    1980-01-01

    Report documents 26-month program to optimize performance of commercial high performance concentric tube solar collector. Report discusses program objectives, accomplishments, encountered problems, and final hardware. Certification test results are also included.

  2. Development of high efficiency collector plates. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Santala, T.; Sabol, R.

    1976-02-01

    Composite metal technology was used to manufacture intermetallic compound (IC) absorption surfaces and to combine them integrally with composite metal tube-in-sheet collector plates. Five material systems in which Al was one component metal and Fe, Cr, or Ni and their alloy was the other pair, were evaluated. All intermetallic compounds had high solar absorptance ..cap alpha.. approx. = 0.9. The AlNi was most promising and ..cap alpha.. > or = 0.95 and epsilon approx. = 0.3 were obtained over a broad range of compounding conditions. After eight months exposure in a flat plate collector enclosure the characteristic properties of AlNi surfaces remained virtually unchanged. Only LCS/Cu composite metal tube-in-sheet collector plates could be manufactured successfully. The technical difficulties associated with integrating the intermetallic compound and tube-in-sheet technologies make the manufacturing of composite metal collector plates at the time being economically unfeasible.

  3. Evaluation performance of helix tube solar collector from nano carbon composite

    Energy Technology Data Exchange (ETDEWEB)

    Boonchom, K. [Rajabhat ChiangMai Univ., ChiangMai (Thailand). Faculty of Science and Technology; Vorasingha, A.; Bongran, T. [Naresuan Univ., Phitsanuloke (Thailand). Faculty of Science; Ketjoy, N. [Naresuan Univ., Phitsanuloke (Thailand). School of Renewable Energy; Souvakon, C. [Rajabhat Uttaradit Univ., Uttaradit , (Thailand). Faculty of Science and Technology

    2006-07-01

    Hot fluid is an essential requirement in both the domestic and industrial sectors. Reducing electricity consumption and energy costs as well as reducing environmental pollution are concerns that have led to the search for more viable and efficient renewable energy sources. A helix tube solar oil heater was designed and manufactured for preheating water in the distillation process of natural products and to preheat seed oil or vegetable oil in the production of bio-diesel. The thermal performance was evaluated by using solar radiation data from the province of Phitsanuloke, Thailand as well as optical parameter absorbance and infrared emissions of nano carbon composite. A solar collector is a device that absorbs the incoming solar radiation, converts it into heat, and then subsequently transfer this heat to a fluid (usually air, water, or oil) flowing through the collector. The design, thermal analysis of collectors, and results and discussion were presented in this paper. It was concluded that there is a good capability of the system to convert the solar energy to heat. 15 refs., 6 tabs., 4 figs.

  4. Copper corrosion and its relationship to solar collectors:a compendium.

    Energy Technology Data Exchange (ETDEWEB)

    Menicucci, David F.; Mahoney, Alan Roderick

    2007-07-01

    Copper has many fine qualities that make it a useful material. It is highly conductive of both heat and electricity, is ductile and workable, and reasonably resistant to corrosion. Because of these advantages, the solar water heating industry has been using it since the mid-1970s as the material of choice for collectors, the fundamental component of a solar water heating system. In most cases copper has performed flawlessly, but in some situations it has been known to fail. Pitting corrosion is the usual failure mode, but erosion can also occur. In 2000 Sandia National Laboratories and the Copper Development Association were asked to analyze the appearance of pin-hole leaks in solar collector units installed in a housing development in Arizona, and in 2002 Sandia analyzed a pitting corrosion event that destroyed a collector system at Camp Pendleton. This report includes copies of the reports and accounts of these corrosion failures, and provides a bibliography with references to many papers and articles that might be of benefit to the solar community. It consolidates in a single source information that has been accumulated at Sandia relative to copper corrosion, especially as it relates to solar water heaters.

  5. Parabolic Trough Solar Collector Initial Trials

    Directory of Open Access Journals (Sweden)

    Ghalya Pikra

    2012-03-01

    Full Text Available This paper discusses initial trials of parabolic trough solar collector (PTSC in Bandung. PTSC model consists of concentrator, absorber and tracking system. Concentrator designs are made with 2m aperture width, 6m length and 0.75m focal distance. The design is equipped with an automatic tracking system which is driven using 12V and 24Watt DC motor with 0.0125rpm rotational speed. Absorber/receiver is designed with evacuated tube type, with 1 inch core diameter and tube made of AISI304 and coated with black oxide, the outer tube is borosilicate glass with a 70 mm diameter and 1.5 m length. Working fluid stored in single type of thermal storage tank, a single phase with 37.7 liter volume. PTSC model testing carried out for 2 hours and 10 minutes produces heat output and input of 11.5 kW and 0.64 kW respectively. 

  6. [Naturalists, collectors and theoreticians of museology].

    Science.gov (United States)

    Arabas, Iwona

    2009-01-01

    The origins of the contemporary collectorship dates from times when the sameness of art and science was commonly accepted. In those days relics of the ancient past and natural individuals of newly discovered lands were presented at the same time. Cosmological character of the collections manifested the tenacity of recognition and representation of the surrounding reality. A great impact on completion of collections of curiosities in Europe had Netherlands, and in the basin of Baltic Sea a remarkable significance was gained by Hanseatic Gdańsk. Collections of Jakub Breyn, Jakub Klein and Gotfryd Reyger became famous then. In the same way were imported individuals for Anna Jabłonowska that composed one of the most interesting European collections. In course of time merging such a great multiplicity of collections was beyond collectors' power and museum pieces from collections of curiosities were parcelled out. It was a real beginning of specialistic museums. A role of museum for science results from its function of methodical organizing collections that can be used by research workers. However, although the aims of scientific and museum centres are different, they come together on the occasion of museum recognition works when museums' workers borrow essential knowledge and methods from resources of science, and scientists search for useful research materials in museum resources.

  7. Multiscale computational modeling of a radiantly driven solar thermal collector

    Science.gov (United States)

    Ponnuru, Koushik

    The objectives of the master's thesis are to present, discuss and apply sequential multiscale modeling that combines analytical, numerical (finite element-based) and computational fluid dynamic (CFD) analysis to assist in the development of a radiantly driven macroscale solar thermal collector for energy harvesting. The solar thermal collector is a novel green energy system that converts solar energy to heat and utilizes dry air as a working heat transfer fluid (HTF). This energy system has important advantages over competitive technologies: it is self-contained (no energy sources are needed), there are no moving parts, no oil or supplementary fluids are needed and it is environmentally friendly since it is powered by solar radiation. This work focuses on the development of multi-physics and multiscale models for predicting the performance of the solar thermal collector. Model construction and validation is organized around three distinct and complementary levels. The first level involves an analytical analysis of the thermal transpiration phenomenon and models for predicting the associated mass flow pumping that occurs in an aerogel membrane in the presence of a large thermal gradient. Within the aerogel, a combination of convection, conduction and radiation occurs simultaneously in a domain where the pore size is comparable to the mean free path of the gas molecules. CFD modeling of thermal transpiration is not possible because all the available commercial CFD codes solve the Navier Stokes equations only for continuum flow, which is based on the assumption that the net molecular mass diffusion is zero. However, thermal transpiration occurs in a flow regime where a non-zero net molecular mass diffusion exists. Thus these effects are modeled by using Sharipov's [2] analytical expression for gas flow characterized by high Knudsen number. The second level uses a detailed CFD model solving Navier Stokes equations for momentum, heat and mass transfer in the various

  8. The transient thermal response of a tubular solar collector

    Science.gov (United States)

    Lansing, F. L.

    1976-01-01

    A special analytical solution is provided for the timewise response of the circulating fluid temperatures when a sudden step change of the input solar radiation is imposed and remains constant thereafter. An example which demonstrates the transient temperatures at the exit section of a single collector with two different flow patterns is presented. This study is used to supplement some numerical solutions to provide a fairly complete coverage for this type of solar collector.

  9. Proceedings of the solar thermal concentrating collector technology symposium

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, B.P.; Kreith, F. (eds.)

    1978-08-01

    The purpose of the symposium was to review the current status of the concentrating collector technology, to disseminate the information gained from experience in operating solar systems, and to highlight the significant areas of technology development that must be vigorously pursued to foster early commercialization of concentrating solar collectors. Separate abstracts were prepared for thirteen invited papers and working group summaries. Two papers were previously abstracted for EDB.

  10. Means of increasing efficiency of CPC solar energy collector

    Science.gov (United States)

    Chao, B.T.; Rabl, A.

    1975-06-27

    A device is provided for improving the thermal efficiency of a cylindrical radiant energy collector. A channel is placed next to and in close proximity to the nonreflective side of an energy reflective wall of a cylindrical collector. A coolant is piped through the channel and removes a portion of the nonreflective energy incident on the wall which is absorbed by the wall. The energy transferred to the coolant may be utilized in a useful manner.

  11. Shape Control of Solar Collectors Using Shape Memory Alloy Actuators

    Science.gov (United States)

    Lobitz, D. W.; Grossman, J. W.; Allen, J. J.; Rice, T. M.; Liang, C.; Davidson, F. M.

    1996-01-01

    Solar collectors that are focused on a central receiver are designed with a mechanism for defocusing the collector or disabling it by turning it out of the path of the sun's rays. This is required to avoid damaging the receiver during periods of inoperability. In either of these two cases a fail-safe operation is very desirable where during power outages the collector passively goes to its defocused or deactivated state. This paper is principally concerned with focusing and defocusing the collector in a fail-safe manner using shape memory alloy actuators. Shape memory alloys are well suited to this application in that once calibrated the actuators can be operated in an on/off mode using a minimal amount of electric power. Also, in contrast to other smart materials that were investigated for this application, shape memory alloys are capable of providing enough stroke at the appropriate force levels to focus the collector. Design and analysis details presented, along with comparisons to test data taken from an actual prototype, demonstrate that the collector can be repeatedly focused and defocused within accuracies required by typical solar energy systems. In this paper the design, analysis and testing of a solar collector which is deformed into its desired shape by shape memory alloy actuators is presented. Computations indicate collector shapes much closer to spherical and with smaller focal lengths can be achieved by moving the actuators inward to a radius of approximately 6 inches. This would require actuators with considerably more stroke and some alternate SMA actuators are currently under consideration. Whatever SMA actuator is finally chosen for this application, repeatability and fatigue tests will be required to investigate the long term performance of the actuator.

  12. Thermal efficiency of single-pass solar air collector

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Zamry; Ibarahim, Zahari; Yatim, Baharudin [School of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor Darul Ehsan (Malaysia); Ruslan, Mohd Hafidz [Solar Energy Research Institute (SERI), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor Darul Ehsan (Malaysia)

    2013-11-27

    Efficiency of a finned single-pass solar air collector was studied. This paper presents the experimental study to investigate the effect of solar radiation and mass flow rate on efficiency. The fins attached at the back of absorbing plate to improve the thermal efficiency of the system. The results show that the efficiency is increased proportional to solar radiation and mass flow rate. Efficiency of the collector archived steady state when reach to certain value or can be said the maximum performance.

  13. Collector sealants and breathing. Final Report, 25 September 1978-31 December 1979

    Energy Technology Data Exchange (ETDEWEB)

    Mendelsohn, M A; Luck, R M; Yeoman, F A; Navish, Jr, F W

    1980-02-20

    The objectives of this program were: (1) to investigate the pertinent properties of a variety of possible sealants for solar collectors and identify the most promising candidates, and (2) to study the effect of breathing in flat-plate, thermal solar collector units. The study involved two types of sealants, Class PS which includes preformed seals or gaskets and Class SC which includes sealing compounds or caulks. It was the intent of the study to obtain data regarding initial properties of candidate elastomers from manufacturers and from the technical literature and to use those sources to provide data pertaining to endurance of these materials under environmental service conditions. Where necessary, these data were augmented by experimental measurements. Environmental stresses evaluated by these measurements included elevated temperatures, moisture, ultraviolet light, ozone and oxygen, and fungus. The second major area of the work involved a study of the effects of materials used and design on the durability of solar collectors. Factors such as design, fabrication, materials of construction, seals and sealing techniques and absorber plate coatings were observed on actual field units removed from service. Such phenomena as leakage, corrosion and formation of deposits on glazing and absorber plate were noted. An evaluation of the properties of several desiccants was made in order to providemeans to mitigate the deleterious effects of water on collector life. Adsorbents for organic degradation products of sealants were also investigated in order to protect the glazing and absorber plate from deposited coatings. Since adsorbents and desiccants in general tend to take up both water and organic decomposition products, relative affinities of a number of these agents for water and for organic compounds were determined . Results are presented in detail.

  14. Collector sealants and breathing. Mid-term report, September 25, 1978-May 30, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Mendelsohn, M. A.; Yeoman, F. A.; Luck, R. M.; Navish, Jr, F. W.; Meier, J. F.

    1978-01-01

    The objectives of this program are: (1) to investigate the pertinent properties of a variety of possible sealants for solar collectors and identify the most promising candidates and to study the effect of breathing in flat-plate, thermal solar collector units. The study involves two types of sealants, Class PS which includes performed seals or gaskets and Class SC which includes sealing compounds or caulks. It is the intent of the study to obtain data regarding initial properties of candidate elastomers from manufacturers and from the technical literature and to use those sources to provide data pertaining to endurance of these materials under environmental service conditions. Where necessary, these data are being augmented by experimental measurements. Environmental stresses to be evaluated by these measuremets include elevated temperatures, moisture, ultraviolet light, ozone and oxygen, and fungus. The second major area of the work involves a study of the effects of materials used and design on the durability of solar collectors. Factors such as design, fabrication, materials of construction, seals and sealing techniques and absorber plate coatings were observed on actual field units removed from service. Such phenomena as leakage, corrosion and formation of deposits on glazing and absorber plate were noted. An evaluation of the properties of several desiccants is being made in order to provide means to mitigate the deleterious effects of water on collector life.Absorbents for organic degradation products of sealants are also being investigated in order to protect the glazing and absorber plate from deposited coatings. Since adsorbents and desiccants in general tend to take up both waer and organic decomposition products, relative affinities of a number of these agents for water and for organic compounds are being determined.

  15. Dual curvature acoustically damped concentrating collector. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Smith, G.A.; Rausch, R.A.

    1980-05-01

    A development program was conducted to investigate the design and performance parameters of a novel, dual curvature, concentrating solar collector. The reflector of the solar collector is achieved with a stretched-film reflective surface that approximates a hyperbolic paraboloid and is capable of line-focusing at concentration ratios ranging from 10 to 20X. A prototype collector was designed based on analytical and experimental component trade-off activities as well as economic analyses of solar thermal heating and cooling systems incorporating this type of collector. A prototype collector incorporating six 0.66 x 1.22 m (2 x 4 ft) was fabricated and subjected to a limited thermal efficiency test program. A peak efficiency of 36% at 121/sup 0/C (250/sup 0/F) was achieved based upon the gross aperture area. Commercialization activities were conducted, including estimated production costs of $134.44/m/sup 2/ ($12.49/ft/sup 2/) for the collector assembly (including a local suntracker and controls) and $24.33/m/sup 2/ ($2.26/ft/sup 2/) for the reflector subassembly.

  16. EFFICIENCY AND LIFETIME OF SOLAR COLLECTORS FOR SOLAR HEATING PLANTS

    DEFF Research Database (Denmark)

    The 12.5 m² flat plate solar collector HT, today marketed by Arcon Solvarme A/S, has been used in solar heating plants in Scandinavia since 1983. The collector is designed to operate in a temperature interval between 40°C and 90°C. The efficiency of the collector has been strongly improved since...... it was introduced on the market. The paper will present the increase of the efficiency of the collector due to technical improvements since 1983. Further, measurements from the spring of 2009 of the efficiency of two HT collectors, which have been in operation in the solar heating plant Ottrupgaard, Skørping......, Denmark since 1994 with a constant high flow rate and in the solar heating plant Marstal, Denmark since 1996 with a variable flow rate, will be presented. The efficiencies will be compared to the efficiencies of the collectors when they were first installed in the solar heating plants. The measurements...

  17. EFFICIENCY AND LIFETIME OF SOLAR COLLECTORS FOR SOLAR HEATING PLANTS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Chen, Ziqian; Furbo, Simon

    2009-01-01

    The 12.5 m² flat plate solar collector HT, today marketed by Arcon Solvarme A/S, has been used in solar heating plants in Scandinavia since 1983. The collector is designed to operate in a temperature interval between 40°C and 90°C. The efficiency of the collector has been strongly improved since...... it was introduced on the market. The paper will present the increase of the efficiency of the collector due to technical improvements since 1983. Further, measurements from the spring of 2009 of the efficiency of two HT collectors, which have been in operation in the solar heating plant Ottrupgaard, Skørping......, Denmark since 1994 with a constant high flow rate and in the solar heating plant Marstal, Denmark since 1996 with a variable flow rate, will be presented. The efficiencies will be compared to the efficiencies of the collectors when they were first installed in the solar heating plants. The measurements...

  18. An improved dynamic test method for solar collectors

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Wang, Zhifeng; Fan, Jianhua

    2012-01-01

    A comprehensive improvement of the mathematical model for the so called transfer function method is presented in this study. This improved transfer function method can estimate the traditional solar collector parameters such as zero loss coefficient and heat loss coefficient. Two new collector...... parameters t and mfCf are obtained. t is a time scale parameter which can indicate the heat transfer ability of the solar collector. mfCf can be used to calculate the fluid volume content in the solar collector or to validate the regression process by comparing it to the physical fluid volume content...... for the second-order differential term with 6–9min as the best averaging time interval. The measured and predicted collector power output of the solar collector are compared during a test of 13days continuously both for the ITF method and the QDT method. The maximum and averaging error is 53.87W/m2 and 5.22W/m2...

  19. An investigation on the performance characteristics of solar flat plate collector with different selective surface coatings

    OpenAIRE

    Madhukeshwara N., E. S. Prakash

    2012-01-01

    In the present work, investigations are made to study performance characteristics of solar flat plate collector with different selective surface coatings. Flat plate collector is one of the important solar energy trapping device which uses air or water as working fluid. Of the many solar collector concepts presently being developed, the relative simple flat plate solar collector has found the widest application so far. Its characteristics are known, and compared with other collector types, it...

  20. Coloured solar collectors. Phase II : from laboratory samples to collector prototypes. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, A.; Roecker, Ch.; Chambrier, E. de; Munari Probst, M.

    2007-07-01

    This illustrated final report for the Swiss Federal Office of Energy (SFOE) deals with the second phase of a project concerning the architectural integration of glazed solar collectors into the facades of buildings for heat production. The factors that limit the integration of photovoltaic panels in facades are discussed. The authors state that, for a convincing demonstration, sufficiently large samples and high quality levels are needed. The sol-gel deposition of the multi-layered coatings on A4-sized glass panes demonstrated in the laboratory by EPFL-LESO are discussed. The coatings produced exhibit a coloured reflection in combination with a high solar transmittance, a homogenous appearance, and are free of visible defects. Film hardening by UV exposure is discussed: This should result in the speeding up of the sol-gel process and thus save energy, thereby significantly reducing costs. Collaboration with industry is discussed in which full-scale glass panes are to be coated with novel multiple layers. The novel glazing is to be integrated into first prototype collectors. The manufacturing and test processes for the prototypes manufactured are discussed in detail.

  1. Effect of openings collectors and solar irradiance on the thermal efficiency of flat plate-finned collector for indirect-type passive solar dryer

    Science.gov (United States)

    Batubara, Fatimah; Dina, Sari Farah; Klaudia Kathryn Y., M.; Turmuzi, M.; Siregar, Fitri; Panjaitan, Nora

    2017-06-01

    Research on the effect of openings solar collector and solar irradiance to thermal efficiency has been done. Solar collector by flat plate-finned type consists of 3 ply insulator namely wood, Styrofoam and Rockwool with thickness respectively are 10 mm, 25 mm and 50 mm. Absorber plate made of aluminum sheet with thickness of 0.30 mm, painted by black-doff. Installation of 19 units fins (length x height x thickness: 1000x20x10 mm) on the collector will increase surface area of absorber so it can receive much more solar energy. The solar collector cover is made of glass (thickness of 5 mm). During the research, the solar irradiance and temperature of collector are measured and recorded every five minutes. Temperature measurement performed on the surface of the absorber plate, inside of collector, surface cover and the outer side insulator (plywood). This data is used to calculate the heat loss due to conduction, convection and radiation on the collector. Openings of collectors vary as follows: 100%, 75%, 15% and 0% (total enclosed). The data collecting was conducted from 09.00 am to 17.00 pm and triplicates. The collector thermal efficiency calculated based on the ratio of the amount of heat received to the solar irradiance absorbed. The results show that each of openings solar collector has different solar irradiance (because it was done on a different day) which is in units of W/m2: 390 (100% open), 376 (75% open), 429 (15% open), and 359 (totally enclosed). The highest thermal efficiency is in openings variation of 15% opened. These results indicate that the efficiency of the collector is influenced by the solar irradiance received by the collector and the temperature on the collector plate. The highest thermal efficiency is in variation of openings 15%. These indicate that the efficiency of the collector was influenced by solar irradiance received by the collector and openings of the collector plate.

  2. Sampling efficiency of the Moore egg collector

    Science.gov (United States)

    Worthington, Thomas A.; Brewer, Shannon K.; Grabowski, Timothy B.; Mueller, Julia

    2013-01-01

    Quantitative studies focusing on the collection of semibuoyant fish eggs, which are associated with a pelagic broadcast-spawning reproductive strategy, are often conducted to evaluate reproductive success. Many of the fishes in this reproductive guild have suffered significant reductions in range and abundance. However, the efficiency of the sampling gear used to evaluate reproduction is often unknown and renders interpretation of the data from these studies difficult. Our objective was to assess the efficiency of a modified Moore egg collector (MEC) using field and laboratory trials. Gear efficiency was assessed by releasing a known quantity of gellan beads with a specific gravity similar to that of eggs from representatives of this reproductive guild (e.g., the Arkansas River Shiner Notropis girardi) into an outdoor flume and recording recaptures. We also used field trials to determine how discharge and release location influenced gear efficiency given current methodological approaches. The flume trials indicated that gear efficiency ranged between 0.0% and 9.5% (n = 57) in a simple 1.83-m-wide channel and was positively related to discharge. Efficiency in the field trials was lower, ranging between 0.0% and 3.6%, and was negatively related to bead release distance from the MEC and discharge. The flume trials indicated that the gellan beads were not distributed uniformly across the channel, although aggregation was reduced at higher discharges. This clustering of passively drifting particles should be considered when selecting placement sites for an MEC; further, the use of multiple devices may be warranted in channels with multiple areas of concentrated flow.

  3. Advanced Hybrid Particulate Collector Project Management Plan

    Energy Technology Data Exchange (ETDEWEB)

    Miller, S.J.

    1995-11-01

    As the consumption of energy increases, its impact on ambient air quality has become a significant concern. Recent studies indicate that fine particles from coal combustion cause health problems as well as atmospheric visibility impairment. These problems are further compounded by the concentration of hazardous trace elements such as mercury, cadmium, selenium, and arsenic in fine particles. Therefore, a current need exists to develop superior, but economical, methods to control emissions of fine particles. Since most of the toxic metals present in coal will be in particulate form, a high level of fine- particle collection appears to be the best method of overall air toxics control. However, over 50% of mercury and a portion of selenium emissions are in vapor form and cannot be collected in particulate control devices. Therefore, this project will focus on developing technology not only to provide ultrahigh collection efficiency of particulate air toxic emissions, but also to capture vapor- phase trace metals such as mercury and selenium. Currently, the primary state-of-the-art technologies for particulate control are fabric filters (baghouses) and electrostatic precipitators (ESPs). However, they both have limitations that prevent them from achieving ultrahigh collection of fine particulate matter and vapor-phase trace metals. The objective of this project is to develop a highly reliable advanced hybrid particulate collector (AHPC) that can provide > 99.99 % particulate collection efficiency for all particle sizes between 0.01 and 50 14m, is applicable for use with all U.S. coals, and is cost-0443competitive with existing technologies. Phase I of the project is organized into three tasks: Task I - Project Management, Reporting, and Subcontract Consulting Task 2 - Modeling, Design, and Construction of 200-acfm AHPC Model Task 3 - Experimental Testing and Subcontract Consulting

  4. Sources

    OpenAIRE

    2014-01-01

    Archives Archivo Histórico del Estado de Jalisco Fondo Gobernación, Asunto Pasaportes y Salvoconductos : G-8-877/9773-9775 G-8-878/9774, 9776, 9777 et 9781 G-8-879/9782-9788 G-8-880/9789-9798 G-8-881-882/9803 G-8-882/9804-9805 G-8-883/9806-9811 G-8-884/9813 G-8-885/9817-9820 G-8-886/9822-9825 G-8-887/9826-9830 G-8-888/9835 G-8-889-890/9837 G-8-889/9839 Sources imprimées Livres et chroniques O’Farrill Romulo, (2004) Reseña histórica estadística y comercial de México y sus estados, directorio g...

  5. Thermal Efficiency of Power Module “Boiler with Solar Collectors as Additional Heat Source” For Combined Heat Supply System

    Directory of Open Access Journals (Sweden)

    Denysova A.E.

    2015-04-01

    Full Text Available The purpose of work is to increase the efficiency of the combined heat supply system with solar collectors as additional thermal generators. In order to optimize the parameters of combined heat supply system the mathematical modeling of thermal processes in multi module solar collectors as additional thermal generators for preheating of the water for boiler have been done. The method of calculation of multi-module solar collectors working with forced circulation for various configurations of hydraulic connection of solar collector modules as the new result of our work have been proposed. The results of numerical simulation of thermal efficiency of solar heat source for boiler of combined heat supply system with the account of design features of the circuit; regime parameters of thermal generators that allow establishing rational conditions of its functioning have been worked out. The conditions of functioning that provide required temperature of heat carrier incoming to boiler and value of flow rate at which the slippage of heat carrier is not possible for different hydraulic circuits of solar modules have been established.

  6. Evaluation of flat-plate collector efficiency under controlled conditions in a solar simulator

    Science.gov (United States)

    Johnson, S. M.; Simon, F. F.

    1976-01-01

    The measured thermal efficiencies of 35 collectors tested with a solar simulator, along with the correlation equations used to generalize the data, are presented in this report. The single correlation used is shown to apply to all the different types of collectors tested, including one with black paint and one cover, one with a selective surface coating and two covers, and an evacuated-tube collector. The test and correlation technique is also modified by using a shield so that collectors larger than the simulator test area can also be tested. This technique was verified experimentally for a shielded collector for which the collector shielded area was 31% of the solar simulator radiation area. A table lists all the collectors tested, the collector areas, and the experimental constants used to correlate the data for each collector.

  7. Techno-economic appraisal of an integrated collector-storage solar water heater

    Energy Technology Data Exchange (ETDEWEB)

    Smyth, M.; Eames, P.C.; Norton, B. [University of Ulster, Newtownabbey (United Kingdom). School of the Built Environment

    2004-07-01

    Integrated collector/storage solar water heaters, due to their simple compact structure and inherent freeze protection, offer a promising approach for solar water heating in colder climates. Such a system, designed specifically for application at a Northern latitude, has been developed incorporating a heat retaining storage vessel mounted within a concentrating cusp reflector supported by a novel exo-skeleton framework. The performance was determined experimentally under real operational conditions in the Northern Irish climate. A detailed cost analysis is presented and payback periods, substituting different local fuel/power sources, determined. (author)

  8. Comparison of Electrical and Thermal Performances of Glazed and Unglazed PVT Collectors

    Directory of Open Access Journals (Sweden)

    Jin-Hee Kim

    2012-01-01

    Full Text Available Photovoltaic-thermal (PVT collectors combine photovoltaic modules and solar thermal collectors, forming a single device that receives solar radiation and produces electricity and heat simultaneously. PVT collectors can produce more energy per unit surface area than side-by-side PV modules and solar thermal collectors. There are two types of liquid-type flat-plate PVT collectors, depending on the existence of glass cover over PV module: glass-covered (glazed PVT collectors, which produce relatively more thermal energy but have lower electrical yield, and uncovered (unglazed PVT collectors, which have relatively lower thermal energy with somewhat higher electrical performance. In this paper, the experimental performance of two types of liquid-type PVT collectors, glazed and unglazed, was analyzed. The electrical and thermal performances of the PVT collectors were measured in outdoor conditions, and the results were compared. The results show that the thermal efficiency of the glazed PVT collector is higher than that of the unglazed PVT collector, but the unglazed collector had higher electrical efficiency than the glazed collector. The overall energy performance of the collectors was compared by combining the values of the average thermal and electrical efficiency.

  9. Atmospheric Ionic Deposition in Tropical Sites of Central Sulawesi Determined by Ion Exchange Resin Collectors and Bulk Water Collector.

    Science.gov (United States)

    Köhler, S; Jungkunst, H F; Gutzler, C; Herrera, R; Gerold, G

    2012-09-01

    In the light of global change, the necessity to monitor atmospheric depositions that have relevant effects on ecosystems is ever increasing particularly for tropical sites. For this study, atmospheric ionic depositions were measured on tropical Central Sulawesi at remote sites with both a conventional bulk water collector system (BWS collector) and with a passive ion exchange resin collector system (IER collector). The principle of IER collector to fix all ionic depositions, i.e. anions and cations, has certain advantages referring to (1) post-deposition transformation processes, (2) low ionic concentrations and (3) low rainfall and associated particulate inputs, e.g. dust or sand. The ionic concentrations to be measured for BWS collectors may easily fall below detection limits under low deposition conditions which are common for tropical sites of low land use intensity. Additionally, BWS collections are not as independent from the amount of rain fallen as are IER collections. For this study, the significant differences between both collectors found for nearly all measured elements were partly correlated to the rainfall pattern, i.e. for calcium, magnesium, potassium and sodium. However, the significant differences were, in most cases, not highly relevant. More relevant differences between the systems were found for aluminium and nitrate (434-484 %). Almost five times higher values for nitrate clarified the advantage of the IER system particularly for low deposition rate which is one particularity of atmospheric ionic deposition in tropical sites of extensive land use. The monthly resolution of the IER data offers new insights into the temporal distribution of annual ionic depositions. Here, it did not follow the tropical rain pattern of a drier season within generally wet conditions.

  10. Effect of the collector tube profile on Pitot pump performances

    Science.gov (United States)

    Komaki, K.; Kanemoto, T.; Sagara, K.; Umekage, T.

    2013-12-01

    The pitot pump is composed of the rotating casing with the impeller channel and the pitot tube type collector as the discharge line. The radial impeller feeds water to the rotating casing. The water rotating together with the casing is caught by the stationary pitot tube type collector, and then discharges to the outside. This type pump, as the extra high head pump, is provided mainly for boiler feed systems, and has been designed by trial and error. To optimize the pump profiles, it is desirable to investigate not only performances but also internal flow conditions. This paper discusses experimentally and numerically the relation between the pump performances and the flow conditions in the rotating casing. The moderately larger dimensions of the collector make the pump head and the discharge high with the higher hydraulic efficiency. The flow in the casing is almost the forced vortex type whose velocity is in proportion to the radius but the core velocity is affected with the drag force of the stationary collector. Based upon the above results, the profile of the pitot tube type collector was optimized with the numerical simulation.

  11. Development of a Small Modular Parabolic trough Collector

    Energy Technology Data Exchange (ETDEWEB)

    Hoffschmidt, B.; Schwarzer, K.; Spate, F.; Kotter, J.; Ebert, M.; Sierck, O.

    2006-07-01

    A small parabolic trough collector is developed with the purpose to achieve a high efficiency at temperatures up to 300 degree Celsius. The collector has an aperture area of 1 m width and 2 m length. Therefore it can be used very easily for roof installations. Tests at the collector test stand of the Solar-Institut Juelich show good results up to 100 degree celsius. The power is about 1 kW. The collector's efficiency is above 50%. Stagnation experiments have shown temperatures around 590 degree celsius at a direct radiation of 730 W/square meters and 7 degree Celsius ambient temperature. The collector consists of a form giving rib construction of stainless steel covered with an aluminum reflector with a reflection coefficient of 95%. A standard vacuum tube (Sidney-principle) 200 cm long is used as absorber. Anti Reflex Glass with a solar transmission of more than 95% is used as cover. The tracking system is consisting of a stepper motor, transmission, sun sensor and electronic steering. (Author)

  12. MERCURY CONTROL WITH ADVANCED HYBRID PARTICULATE COLLECTOR

    Energy Technology Data Exchange (ETDEWEB)

    Ye Zhuang; Stanley J. Miller

    2005-05-01

    This project was awarded under U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) Program Solicitation DE-PS26-00NT40769 and specifically addressed Technical Topical Area 4-Testing Novel and Less Mature Control Technologies on Actual Flue Gas at the Pilot Scale. The project team included the Energy & Environmental Research Center (EERC) as the main contractor; W.L. Gore & Associates, Inc., as a technical and financial partner; and the Big Stone Power Plant operated by Otter Tail Power Company, host for the field-testing portion of the research. Since 1995, DOE has supported development of a new concept in particulate control called the advanced hybrid particulate collector (AHPC). The AHPC has been licensed to W.L. Gore & Associates, Inc., and has been marketed as the Advanced Hybrid{trademark} filter by Gore. The Advanced Hybrid{trademark} filter combines the best features of electrostatic precipitators (ESPs) and baghouses in a unique configuration, providing major synergism between the two collection methods, both in the particulate collection step and in the transfer of dust to the hopper. The Advanced Hybrid{trademark} filter provides ultrahigh collection efficiency, overcoming the problem of excessive fine-particle emissions with conventional ESPs, and it solves the problem of reentrainment and re-collection of dust in conventional baghouses. The Advanced Hybrid{trademark} filter also appears to have unique advantages for mercury control over baghouses or ESPs as an excellent gas--solid contactor. The objective of the project was to demonstrate 90% total mercury control in the Advanced Hybrid{trademark} filter at a lower cost than current mercury control estimates. The approach included bench-scale batch tests, larger-scale pilot testing with real flue gas on a coal-fired combustion system, and field demonstration at the 2.5-MW (9000-acfm) scale at a utility power plant to prove scale-up and demonstrate longer-term mercury control

  13. Development of 12.5 m² Solar Collector Panel for Solar Heating Plants

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian; Furbo, Simon; Shah, Louise Jivan

    2004-01-01

    Theoretical and experimental investigations have elucidated how different changes in the design of the 12.5 m(2) HT flat-plate solar collector from the Danish company ARCON Solvarme A/S influence the solar collector efficiency and the yearly thermal performance. The collector is designed for medium...... and large solar heating systems. Based on the theoretical findings a prototype of an improved HT solar collector was built and tested side-by-side with the original HT solar collector. The improved HT collector makes use of a changed insulation material, an absorber with improved absorptance and emittance...

  14. Optimization of solar air collector using genetic algorithm and artificial bee colony algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Sencan Sahin, Arzu [Sueleyman Demirel University, Technology Faculty, Isparta (Turkey)

    2012-11-15

    Thermal performance of solar air collector depends on many parameters as inlet air temperature, air velocity, collector slope and properties related to collector. In this study, the effect of the different parameters which affect the performance of the solar air collector are investigated. In order to maximize the thermal performance of a solar air collector genetic algorithm (GA) and artificial bee colony algorithm (ABC) have been used. The results obtained indicate that GA and ABC algorithms can be applied successfully for the optimization of the thermal performance of solar air collector. (orig.)

  15. A solar collector design procedure for crop drying

    Directory of Open Access Journals (Sweden)

    B. M. Santos

    2005-06-01

    Full Text Available A design procedure was proposed for sizing solar-assisted crop-drying systems and assessing the combination of solar collector area and auxiliary energy needs that meets the requirements of the load. Two empirical correlations were compared for use with high thermal inertia solar collectors that are cheap and appropriate for rural areas. A case study as performed in the city of Campinas in southeastern Brazil. Grain drying with partial air heating by solar energy can provide an annual savings of 30% in fuel consumption for 1.80m² collector area during the drying of 1.2t of corn at 50ºC at a daily air rate of 1526.8 m³/day.

  16. MSFC hot air collectors. Phase 1: Test report

    Science.gov (United States)

    Losey, R.

    1977-01-01

    A development test program of 3 hot air flat plate solar collectors is described in detail. The pressure drop versus flow rate performance characteristics for these collectors, mounted in series, was determined under 14 different test conditions each of which was characterized by a unique combination of inlet air temperature and air flow rate. Characteristics of inlet, exit and transfer ducts of these collectors were also determined during this testing. The test results indicate that significant pressure drop occurs at air flow rates greater than 150 standard cubic feet per minute and this drop is not heavily dependent upon inlet air temperature; and inlet, exit and transfer duct characteristics differ sufficiently to suggest that system performance may be enhanced through careful design of each type of duct individually.

  17. Absorber Alignment Measurement Tool for Solar Parabolic Trough Collectors: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Stynes, J. K.; Ihas, B.

    2012-04-01

    As we pursue efforts to lower the capital and installation costs of parabolic trough solar collectors, it is essential to maintain high optical performance. While there are many optical tools available to measure the reflector slope errors of parabolic trough solar collectors, there are few tools to measure the absorber alignment. A new method is presented here to measure the absorber alignment in two dimensions to within 0.5 cm. The absorber alignment is measured using a digital camera and four photogrammetric targets. Physical contact with the receiver absorber or glass is not necessary. The alignment of the absorber is measured along its full length so that sagging of the absorber can be quantified with this technique. The resulting absorber alignment measurement provides critical information required to accurately determine the intercept factor of a collector.

  18. IEA/SPS 500 kW distributed collector system

    Science.gov (United States)

    Neumann, T. W.; Hartman, C. D.

    1980-01-01

    Engineering studies for an International Energy Agency project for the design and construction of a 500 kW solar thermal electric power generation system of the distributed collector system (DCS) type are reviewed. The DCS system design consists of a mixed field of parabolic trough type solar collectors which are used to heat a thermal heat transfer oil. Heated oil is delivered to a thermocline storage tank from which heat is extracted and delivered to a boiler by a second heat transfer loop using the same heat transfer oil. Steam is generated in the boiler, expanded through a steam turbine, and recirculated through a condenser system cooled by a wet cooling tower.

  19. Attractive economy and durability of building integrated solar collector systems

    Energy Technology Data Exchange (ETDEWEB)

    Vejsig Pedersen, P.; Vejsig Pedersen, P.

    1986-05-01

    An advantage of building integrated solar collector systems is that often the solar components also function as a building envelope. Two demonstration projects with large roof integrated, site-built solar collectors for DHW built near Copenhagen are described. One solar collector has 208 m/sup 2/ of collector area integrated in an existing building and forming part of a roof renovation. The other solar collector has a collector area of 160 m/sup 2/ and was used in a new building project. The solar collector was developed with a special acrylic glazing which is easy to install. It is completely rain tight and well ventilated. In a building project north of Copenhagen, where 40 out of 55 solar low energy houses were equipped with a new type of compact thermosyphon solar water heater, originally developed at the Thermal Insulation Laboratory is described. Integrated in the wall in the living room, a selective absorber and 16 cm thick, 150 liter DHW tank with an electric heater as back-up, were installed behind an ordinary 3.5 m/sup 2/ window with a tilt of 57 deg. 3 monitored systems show that a yearly system efficiency of 50% is possible for a daily DHW demand of 200 liter being equal to a solar fraction of 65% or a coefficient of performance of 3.0 Economic aspects are also dealt with. At the Thermal Insulation Laboratory, several passive solar heating research projects have also been carried out. However, to obtain better possibilities for control, which can be necessary in an unstable climate like the Danish, various hybrid heating systems have been investigated. An example is the so-called loft room solar collector. This system is an ordinary, black painted loft room with a transparent roofing. A rock-bed storage is charged by air heated in the loft room. This is an inexpensive solar system with a quite high solar fraction. The importance of using solar technology in new building projects is discussed. 11 refs.

  20. Self-tracking radiant energy collector

    Energy Technology Data Exchange (ETDEWEB)

    Steiner, R.E.

    1978-05-30

    A solar energy conversion device is provided with simplified means for tracking a source of solar energy. In the preferred embodiment, the tracking means is a predeterminedly shaped, heat expandable device operatively connected to an energy concentrator. The energy concentrator is movably mounted and is adapted to direct concentrated energy either towards a suitable energy conversion means in those positions in which the concentration is aligned with respect to the solar energy source, or towards the expandable device in those positions in which the concentrator is disaligned with respect to the solar energy source. Application of concentrated solar energy to the expandable device causes its expansion, which expansion is utilized to move the concentrator into alignment with the energy source. At alignment, concentrated energy is directed from the expandable device toward the energy conversion means.

  1. A Mathematical Model for the Temperature Field in the Absorber of a New Type Solar Collector

    National Research Council Canada - National Science Library

    P Shipkov; V Barkans; M van ags; L Vasilevska

    2010-01-01

      A Mathematical Model for the Temperature Field in the Absorber of a New Type Solar Collector The temperature field problem described in the paper is analytically solved for the absorber of a new type solar collector...

  2. EVALUATION OF EVACUATED TUBULAR SOLAR COLLECTORS FOR LARGE SDHW SYSTEMS AND COMBINED SPACE HEATING SYSTEMS

    DEFF Research Database (Denmark)

    Qin, Lin; Furbo, Simon

    1999-01-01

    . Based on thesemodels, the thermal performance of large solar domestic hot water (DHW) systems and combined domestichot water and space heating systems with the four evacuated tubular collectors was determined. To make acomparison with traditional flat-plate collectors, similar simulations were also......In the present study, detailed investigations on evacuated tubular solar collectors for large solarheating systems have been carried out. Four types of evacuated tubular solar collectors were used in theinvestigation. Based on laboratory tests, simulation models for the collectors were determined...... carried out for systems with atypical flat-plate collector. The results show that the thermal advantage of evacuated tubular collectors variesgreatly from system to system, and increases with the solar fraction. Furthermore, the higher the operationtemperature of the collector in the system is...

  3. FLOW DISTRIBUTION IN A SOLAR COLLECTOR PANEL WITH HORIZONTAL ABSORBER STRIPS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    2007-01-01

    The objective of this work is to theoretically and experimentally investigate the flow and temperature distribution in a solar collector panel with an absorber consisting of horizontal strips. Fluid flow and heat transfer in the collector panel are studied by means of computational fluid dynamics...... (CFD) calculations. Further, experimental investigations of a 12.5 m² solar collector panel with 16 parallel connected horizontal fins are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the backside of the absorber tubes. The measured...... collector fluid, and by increased collector tilt and inlet temperature, the flow distribution gets worse resulting in a decreased collector efficiency and an increased risk of boiling in the upper part of the collector panel. Keywords: Solar collector; Flow distribution; Computational Fluid Dynamics (CFD...

  4. The Effect of the Volume Flow rate on the Efficiency of a Solar Collector

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    rates. Theoretically, a simplified model of the solar collector panel is built by means of the CFD (Computational Fluid Dynamics) code Fluent, where the geometry of the collector panel except the casing is fully modeled. Both lateral and longitudinal heat conduction in the absorber fins, the heat...... transfer from the absorber to the solar collector fluid and the heat loss from the absorber are considered. Flow and temperature distribution in the collector panel are investigated with buoyancy effect. Measurements are carried out with the solar collector panel. Collector efficiencies are measured......The flow distribution inside a collector panel with an area of 12.5 m² and with 16 parallel connected horizontal fins and the effect of the flow nonuniformity on the risk of boiling and on the collector efficiency have been theoretically and experimentally investigated for different volume flow...

  5. Performance evaluation of the solar kinetics T-700 line concentrating solar collector

    Science.gov (United States)

    1981-01-01

    A performance evaluation of the solar kinetics T-700 line concentrating solar collector is reported. Collector descriptions, summary, test conditions, test equipment, test requirements and procedures, and an analysis of the various tests performed are described.

  6. VALIDATION OF SIMULATION MODELS FOR DIFFERENTLY DESIGNED HEAT-PIPE EVACUATED TUBULAR COLLECTORS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Dragsted, Janne; Furbo, Simon

    2007-01-01

    Differently designed heat-pipe evacuated tubular collectors have been investigated theoretically and experimentally. The theoretical work has included development of two TRNSYS [1] simulation models for heat-pipe evacuated tubular collectors utilizing solar radiation from all directions. One model...... is developed for heat-pipe evacuated tubular collectors with flat fins and one model is developed for heat-pipe evacuated tubular collectors with curved fins. The models are characterized by detailed calculations of the heat transfer processes in the fins, by detailed shadow modeling and by fins with selective...... coating on both sides. The input to the models is thus not a simple collector efficiency expression but the actual collector geometry. In this study, the TRNSYS models are validated with measurements for four differently designed heat-pipe evacuated tubular collectors. The collectors are produced...

  7. Thermal and Electrical Performance Evaluation of PV/T Collectors in UAE

    OpenAIRE

    Kaya, Mustafa

    2013-01-01

    Photovoltaic Thermal/Hybrid collectors are an emerging technology that combines PV and solar thermal collectors by producing heat and electricity simultaneously. In this paper, thermal and electrical performance of PV/T collectors are analyzed and presented for the climate of RAK, UAE. Thermal performance evaluation is done following the collector output model presented in European standard EN 12975-2 and electrical performance evaluation is done by analyzing the effect of water circulation o...

  8. Flat-plate collector performance evaluation. The case for a solar simulation approach

    Science.gov (United States)

    Simon, F. F.; Harlamert, P.

    1973-01-01

    A method is proposed for determining the performance of flat-plate solar collector using a simulated sun. Collector test variables that will help establish the basis for the indoor test facility at the Lewis Research Center are discussed. The use of the indoor testing should permit a standard test for the convenient and accurate determination of collector performance. Preliminary test results are reported as an example of the type of collector performance data to be expected from the simulation approach.

  9. Using Collector for ArcGIS for Field Surveys

    OpenAIRE

    Meador, Chris; Horn, Adam

    2017-01-01

    In this session we discuss the use of mobile devices such as tablets and cell phones to complete field surveys using the Collector app. This app is a product of ArcGIS and allows for collection of points, lines, areas, and other related data in the field without internet or home network connection. It also makes completing data forms easy.

  10. Dynamic Modeling of Natural Convection Solar Energy Collector

    African Journals Online (AJOL)

    NIJOTECH

    which occurred between 1800s and 3600s after solar noon where global radiation had its maximum. The shift is attributable to the heat capacities of the materials of the collector Separation of the transient terms from the steady- state terms for the plates' temperatures showed the transient contribution to be very small and ...

  11. Solar-collector manufacturing activity, July through December, 1981

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-03-01

    Solar thermal collector and solar cell manufacturing activity is both summarized and tabulated. Data are compared for three survey periods (July through December, 1981; January through June, 1981; and July through December, 1980). Annual totals are also provided for the years 1979 through 1981. Data include total producer shipments, end use, market sector, imports and exports. (LEW)

  12. Certification and verification for calmac flat plate solar collector

    Energy Technology Data Exchange (ETDEWEB)

    1978-01-27

    This document contains information used in the certification and verification of the Calmac Flat Plate Collector. Contained are such items as test procedures and results, information on materials used, Installation, Operation, and Maintenance Manuals, and other information pertaining to the verification and certification.

  13. Solar Thermal AIR Collector Based on New Type Selective Coating

    Directory of Open Access Journals (Sweden)

    Musiy, R.Y.

    2014-01-01

    Full Text Available Based on the best for optical performance and selective coating solar thermal air collector, which operates by solar power on the principle of simultaneous ventilation and heating facilities, is designed. It can be used for vacation homes, museums, wooden churches, warehouses, garages, houses, greenhouses etc.

  14. Genesis Solar Wind Collector Cleaning Assessment: 60366 Sample Case Study

    Science.gov (United States)

    Goreva, Y. S.; Gonzalez, C. P.; Kuhlman, K. R.; Burnett, D. S.; Woolum, D.; Jurewicz, A. J.; Allton, J. H.; Rodriguez, M. C.; Burkett, P. J.

    2014-01-01

    In order to recognize, localize, characterize and remove particle and thin film surface contamination, a small subset of Genesis mission collector fragments are being subjected to extensive study via various techniques [1-5]. Here we present preliminary results for sample 60336, a Czochralski silicon (Si-CZ) based wafer from the bulk array (B/C).

  15. Performance simulation of parabolic trough solar collector using two ...

    African Journals Online (AJOL)

    The Parabolic trough solar collector is considered as one of the most proven, mature and commercial concentrating solar systems implemented in arid and semi-arid regions for energy production. It focuses sunlight onto a solar receiver by using mirrors and is finally converted to a useful thermal energy by means of a heat ...

  16. Dynamic Modeling of Natural Convection Solar Energy Collectors ...

    African Journals Online (AJOL)

    This was confirmed when the transient terms were completely deleted as the maximum values of the output parameters and their times of occurrence remained the same in both cases. The developed output expressions (in closed form) for the dynamic model of flat plate solar energy air heating collectors can easily be used ...

  17. A note on critical flow section in collector channels

    Indian Academy of Sciences (India)

    Springer Verlag Heidelberg #4 2048 1996 Dec 15 10:16:45

    received no attention so far. The aim of the present study is to report a methodology for generalized solution of critical flow section in collector ..... Churchill S W 1977 Friction factor equation spans all fluid regimes. Chem. Eng. 84: 91–92. Conte S D, de Boor C 1987 Elementary numerical analysis: an algorithmic approach ( ...

  18. Modified Evacuated-Tube Collector Tested in Solar Simulator

    Science.gov (United States)

    1982-01-01

    According to report, particular commercial evacuated-tube solar collector performs slightly more efficiently with larger manifold. Tests were performed with Marshall Space Flight Center solar simulator. Report describes test conditions and procedures, provides analysis of results, and presents tables and graphs of data, both measured and calculated.

  19. Evaluation of an evacuated-tube liquid solar collector

    Science.gov (United States)

    1981-01-01

    Indoor and outdoor thermal performances of collectors are compared in report. Tests conducted on indoor solar simulator with data from both diffuse and specular reflectors are presented graphically and in tables. Comparisons with previous data for prototype show effects of improved mainfold.

  20. Evacuated-tube solar collector--performance evaluation

    Science.gov (United States)

    1980-01-01

    Report gives thermal performance test procedures and results for commercially produced, water-filled, 8-tube collectors. Tests include efficiency, time constant for temperature drop after solar flux is cut, change in efficiency as function of sun angle, and test to see if tubes break when filled with hot water.

  1. Development of nonmetallic solar collector and solar-powered pump

    Science.gov (United States)

    Parker, J. C.

    1979-01-01

    Design and building of two unique components for solar heating (1. flatplate solar collector using no metal components, and 2. solar powered pump for heating and cooling systems are outlined in report. Report also discusses hardware, deliverable end items, problems encountered during fabrication and testing, and performance certification.

  2. Testing of a solar collector with concentrating mirrors

    Science.gov (United States)

    1980-01-01

    Commerical flat-plate solar collector with concentrating mirrors has been tested for thermal performance, structured behavior under static load, and effects of long-term natural weathering. Report documents results of testing and concludes that absorptivity was degraded by weathering.

  3. Dynamic Modeling of Natural Convection Solar Energy Collector

    African Journals Online (AJOL)

    NIJOTECH

    ENERGY COLLECTORS FOR AGRICULTURAL DRIERS I: THEORY. AND COMPLETE RUN OF THE SOLUTIONS TO ... agricultural products like meat, fish, grains and vegetables and bring them to acceptable equilibrium moisture content to ... Sun in the forms of heat and light (two forms of electromagnetic radiations), life.

  4. Macrofauna Settlement on Pearl Oyster Collectors in Kenya ...

    African Journals Online (AJOL)

    Interest in pearl culture in the Western Indian Ocean ... West Indian Ocean. These include the settlement of mangrove oyster, Saccostrea cucullata within the intertidal zone in Kenya (Van Someren and. Whitehead ..... Abundance of different species/taxa (mean±SE) identified from black plastic sheet collectors deployed.

  5. Experimental performance analysis for mini-parabolic solar reflecting collectors

    Energy Technology Data Exchange (ETDEWEB)

    Barakos, G.; Kaplanis, S.; Spyrogiannoulas, A. [Technological Educational Inst. of Patras, Patra (Greece)

    2007-07-01

    This paper presented a detailed analysis of the thermal behaviour of a mini-parabolic solar reflecting collector installed on the roof of a building. A data logging system was used to monitor fluid inlet and outlet temperatures in the absorber; total solar radiation incident on the aperture surface; ambient temperatures; and fluid flow measurements. The aim of the study was to increase the reliability of the collector, maximize output, and optimize the geometrical and physical characteristics of the collector's components. Experiments were conducted over a 4-day period in October and November 2006 at a location in Greece. Data obtained during the experiments showed that as the mass flow rate increased, the outlet and inlet temperatures decreased. The system's efficiency increased as the mass flow rate increased. Losses were decreased when temperatures in the tube absorber remained low. The results of several subsequent experiments confirmed that higher mass flow rates increase the efficiency of the collectors.15 refs., 10 figs.

  6. On the Adsorption of Some Anionic Collectors on Fluoride Minerals

    DEFF Research Database (Denmark)

    Sørensen, Emil

    1973-01-01

    Test flotations have been carried out in a small apparatus under standardized conditions in order to determine the dependence of the flotation yield on the reagent concentration for certain minerals and anionic collectors. The results suggest that a special adsorption mechanism is operating...

  7. Inverse Marx modulators for self-biasing klystron depressed collectors

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, Mark A; /SLAC

    2014-07-31

    A novel pulsed depressed collector biasing scheme is proposed. This topology feeds forward energy recovered during one RF pulse for use on the following RF pulse. The presented ''inverse'' Marx charges biasing capacitors in series, and discharges them in parallel. Simulations are shown along with experimental demonstration on a 62kW klystron.

  8. FTIR Analysis of Aerogel Keystones from the Stardust Interstellar Dust Collector: Assessment of Terrestrial Organic Contamination and X-Ray Microprobe Beam Damage

    Science.gov (United States)

    Zolensky, M. E.; Bechtel, H. A.; Allen, C.; Bajt, S.; Borg, J.; Brenker, F.; Bridges, J.; Brownlee, D. E.; Burchell, M.; Burghammer, M.; hide

    2011-01-01

    The Stardust Interstellar Dust Collector (SIDC) was intended to capture and return contemporary interstellar dust. The approx.0.1 sq m collector was composed of aerogel tiles (85% of the collecting area) and aluminum foils and was exposed to the interstellar dust stream for a total exposure factor of 20 sq m day. The Stardust Interstellar Preliminary Examination (ISPE) is a consortium-based project to characterize the collection using nondestructive techniques. Sandford et al. recently assessed numerous potential sources of organic contaminants in the Stardust cometary collector. These contaminants could greatly complicate the analysis and interperetation of any organics associated with interstellar dust, particularly because signals from these particles are expected to be exceedingly small. Here, we present a summary of FTIR analyses of over 20 aerogel keystones, many of which contained candidates for interstellar dust.

  9. Modelling and performance study of a continuous adsorption refrigeration system driven by parabolic trough solar collector

    Energy Technology Data Exchange (ETDEWEB)

    Fadar, A. El; Mimet, A. [Energetics Laboratory, Sciences Faculty, Abdelmalek Essaadi University, BP 2121, 93000 Tetouan (Morocco); Perez-Garcia, M. [Dpto. de Fisica Aplicada, Universidad de Almeria (Spain)

    2009-06-15

    This article suggests a numerical study of a continuous adsorption refrigeration system consisting of two adsorbent beds and powered by parabolic trough solar collector (PTC). Activated carbon as adsorbent and ammonia as refrigerant are selected. A predictive model accounting for heat balance in the solar collector components and instantaneous heat and mass transfer in adsorbent bed is presented. The validity of the theoretical model has been tested by comparison with experimental data of the temperature evolution within the adsorber during isosteric heating phase. A good agreement is obtained. The system performance is assessed in terms of specific cooling power (SCP), refrigeration cycle COP (COP{sub cycle}) and solar coefficient of performance (COP{sub s}), which were evaluated by a cycle simulation computer program. The temperature, pressure and adsorbed mass profiles in the two adsorbers have been shown. The influences of some important operating and design parameters on the system performance have been analyzed. The study has put in evidence the ability of such a system to achieve a promising performance and to overcome the intermittence of the adsorption refrigeration systems driven by solar energy. Under the climatic conditions of daily solar radiation being about 14 MJ per 0.8 m{sup 2} (17.5 MJ/m{sup 2}) and operating conditions of evaporating temperature, T{sub ev} = 0 C, condensing temperature, T{sub con} = 30 C and heat source temperature of 100 C, the results indicate that the system could achieve a SCP of the order of 104 W/kg, a refrigeration cycle COP of 0.43, and it could produce a daily useful cooling of 2515 kJ per 0.8 m{sup 2} of collector area, while its gross solar COP could reach 0.18. (author)

  10. Design, Implementation & Assessment of Local Exhaust Ventilation System and dust collectors for crushing unit

    Directory of Open Access Journals (Sweden)

    Farshid Ghorbani shahna

    2015-09-01

    Full Text Available Background & objective: Industrial ventilation systems and dust collectors are effective solutions to reduce particulate emissions in the workplace and environmental in mineral processes. In this study, Local Exhaust Ventilation System and dust collectors for control of emitted silica, coke, silicon carbide dusts from crushing unit was designed and evaluated. Methods: : Local Exhaust ventilation system based on standards and guides was designed and implemented after field study of the processes and sources of air pollutants. A set comprised of the four parallel cyclones (Stairmand model and a new design of the scrubber had been used for dust control. After set-up of systems, its effectiveness in reducing the exposure of workers in the workshops and dust collecting were assessed. Results: Test results were significant differences between the concentration of particles in both on and off the ventilation system revealed (P <0.05. The system has been implemented as means of personal exposure to pollutants and environmental emissions were reduced 93.01% and 64.64%, respectively. Also, alone and integrated collection efficiency of cyclone and scrubber, were 94.2%, 59.05% and 97.4%, respectively. The results show good agreement with the values of the parameters ventilation system was designed. Conclusion: Implementation of integrated dust collectors is a good option in industries that have the financial and technical constraints to improve change processes and devices. This method with attainment to health and environmental standards not only can be resolve of the pollution problems, but also will be economically justified of such projects with reduction of depreciation expense and dust recycling.

  11. Energy and exergy analysis of PV/T air collectors connected in series

    NARCIS (Netherlands)

    Dubey, Swapnil; Solanki, S.C.; Tiwari, A.

    2009-01-01

    In this paper an attempt has been made to derive the analytical expressions for N hybrid photovoltaic/thermal (PV/T) air collectors connected in series. The performance of collectors is evaluated by considering the two different cases, namely, Case I (air collector is fully covered by PV module

  12. Design and installation package for the Sunmat Flat Plate Solar Collector

    Energy Technology Data Exchange (ETDEWEB)

    1978-03-01

    The information used in evaluating the design of the Sunmat Liquid Flat Plat Plate Solar Collector developed by Calmac Manufacturing Company is presented. Included in this package are the Subsystem Performance Specification, Installation, Operation and Maintenance Manuals, collector sizing guides, and detailed drawings of the single-glazed collector.

  13. Glazed PVT Collector with Polysiloxane Encapsulation of PV Cells: Performance and Economic Analysis

    Directory of Open Access Journals (Sweden)

    Tomas Matuska

    2015-01-01

    Full Text Available Development of a new concept of glazed PVT collector based on temperature resistant polysiloxane encapsulation material is presented together with the results from experimental testing and modelling. Performance and economic analysis in 4 different European climates has been done to derive the competitive price of the PVT collector concepts with main focus on the glazed PVT collector under development. Results have shown that specific market price 400 to 500 EUR/m2 for the glazed PVT collector should not be exceeded in order to become competitive with conventional combination of photothermal and photovoltaic collectors.

  14. Experimental and simulation studies of parabolic trough collector design for obtaining solar energy

    Directory of Open Access Journals (Sweden)

    Syed Ameen Murtuza

    2017-12-01

    Full Text Available Concentrated solar power has great potential for large scale renewable energy sources, and is currently an eye catching one for its utilization with wide area of improvement. Especially, parabolic trough solar collectors (PTSCs are gaining popularity due to their increased efficiency as compared to photovoltaics. In this work, an effort has been made to evaluate the performance of a designed 5-m length PTSC model. Heat collecting element was made of stainless steel with water as working fluid. The authentication of the proposed model is justified based on the results obtained on a yearly scale with respect to average inlet and outlet temperatures, surface temperatures and thermal efficiency for the climatic conditions of Ramanagaram. It was observed that March to May yielded better outlet temperatures ranging from 93 °C to 103 °C. Experiments were carried out at different flow rates of 0.4 LPM, 0.8 LPM and 1.2 LPM and corresponding Reynolds number was calculated. It was seen that February to May gave good surface and outlet temperatures as compared with other months while the liquid flow is laminar. Simulation studies were carried out using ANSYS software on receiver tube to ensure the robustness and design effectiveness under static loading conditions. Keywords: Parabolic trough solar collector, Receiver tube, Solar thermal, Static structural analysis

  15. CHEMICAL COMPOSITION OF IRRIGATION, COLLECTOR-AND-DRAINAGE AND GROUND WATERS OF THE LOWER ALAZANI VALLEY

    Directory of Open Access Journals (Sweden)

    MARIAM ELIZBARASHVILI

    2016-03-01

    Full Text Available Kakheti region is one of the important regions for agriculture development in Georgia. Salinized soils (54 thou. hectares are extended in the area of Alazani valley, in Sighnaghi region of Kakheti. Sighnaghi region is poor with water resources and atmospheric precipitations. Air temperature in summer months reaches here 35-40°C that along with extended period without precipitations often becomes the reason of droughts. Chemical composition of irrigation channel, collector-and-drainage and ground waters of the Lower Alazani Valley in Sighnaghi region of Kakheti is considered in the work. It is established that the water of Lower Alazani irrigation channel is suitable for irrigation; collector-and-drainage waters in case of low mineralization may be used as the additional source of irrigation; ground waters belong to the category of ground waters of high salinity and at the same time mineralization have a tendency to change according to seasons, in particular, mineralization increases in summer and autumn.

  16. Nanofluid Types, Their Synthesis, Properties and Incorporation in Direct Solar Thermal Collectors: A Review

    Science.gov (United States)

    Chamsa-ard, Wisut; Brundavanam, Sridevi; Fung, Chun Che; Fawcett, Derek; Poinern, Gerrard

    2017-01-01

    The global demand for energy is increasing and the detrimental consequences of rising greenhouse gas emissions, global warming and environmental degradation present major challenges. Solar energy offers a clean and viable renewable energy source with the potential to alleviate the detrimental consequences normally associated with fossil fuel-based energy generation. However, there are two inherent problems associated with conventional solar thermal energy conversion systems. The first involves low thermal conductivity values of heat transfer fluids, and the second involves the poor optical properties of many absorbers and their coating. Hence, there is an imperative need to improve both thermal and optical properties of current solar conversion systems. Direct solar thermal absorption collectors incorporating a nanofluid offers the opportunity to achieve significant improvements in both optical and thermal performance. Since nanofluids offer much greater heat absorbing and heat transfer properties compared to traditional working fluids. The review summarizes current research in this innovative field. It discusses direct solar absorber collectors and methods for improving their performance. This is followed by a discussion of the various types of nanofluids available and the synthesis techniques used to manufacture them. In closing, a brief discussion of nanofluid property modelling is also presented. PMID:28561802

  17. Nanofluid Types, Their Synthesis, Properties and Incorporation in Direct Solar Thermal Collectors: A Review.

    Science.gov (United States)

    Chamsa-Ard, Wisut; Brundavanam, Sridevi; Fung, Chun Che; Fawcett, Derek; Poinern, Gerrard

    2017-05-31

    The global demand for energy is increasing and the detrimental consequences of rising greenhouse gas emissions, global warming and environmental degradation present major challenges. Solar energy offers a clean and viable renewable energy source with the potential to alleviate the detrimental consequences normally associated with fossil fuel-based energy generation. However, there are two inherent problems associated with conventional solar thermal energy conversion systems. The first involves low thermal conductivity values of heat transfer fluids, and the second involves the poor optical properties of many absorbers and their coating. Hence, there is an imperative need to improve both thermal and optical properties of current solar conversion systems. Direct solar thermal absorption collectors incorporating a nanofluid offers the opportunity to achieve significant improvements in both optical and thermal performance. Since nanofluids offer much greater heat absorbing and heat transfer properties compared to traditional working fluids. The review summarizes current research in this innovative field. It discusses direct solar absorber collectors and methods for improving their performance. This is followed by a discussion of the various types of nanofluids available and the synthesis techniques used to manufacture them. In closing, a brief discussion of nanofluid property modelling is also presented.

  18. Nanofluid Types, Their Synthesis, Properties and Incorporation in Direct Solar Thermal Collectors: A Review

    Directory of Open Access Journals (Sweden)

    Wisut Chamsa-ard

    2017-05-01

    Full Text Available The global demand for energy is increasing and the detrimental consequences of rising greenhouse gas emissions, global warming and environmental degradation present major challenges. Solar energy offers a clean and viable renewable energy source with the potential to alleviate the detrimental consequences normally associated with fossil fuel-based energy generation. However, there are two inherent problems associated with conventional solar thermal energy conversion systems. The first involves low thermal conductivity values of heat transfer fluids, and the second involves the poor optical properties of many absorbers and their coating. Hence, there is an imperative need to improve both thermal and optical properties of current solar conversion systems. Direct solar thermal absorption collectors incorporating a nanofluid offers the opportunity to achieve significant improvements in both optical and thermal performance. Since nanofluids offer much greater heat absorbing and heat transfer properties compared to traditional working fluids. The review summarizes current research in this innovative field. It discusses direct solar absorber collectors and methods for improving their performance. This is followed by a discussion of the various types of nanofluids available and the synthesis techniques used to manufacture them. In closing, a brief discussion of nanofluid property modelling is also presented.

  19. Solar assisted heat pump system with volume solar collector. Technical report

    Energy Technology Data Exchange (ETDEWEB)

    Sabnis, J.S.; Hickox, W.J.; Drucker, E.E.; Ucar, M.; LaGraff, J.E.

    1978-09-01

    The system uses the attic of the house with a large south facing window as the solar collector. An air-to-water heat pump uses the attic air as a heat source to heat a volume of storage water during the heating season. During the cooling season the attic is ventilated and the heat pump uses the attic air as a heat sink while cooling the storage water. The computer program was developed to include a heat exchanger in the attic which could by-pass the heat pump condenser cooling water, thus permitting direct heat exchange between the attic air and the storage water whenever a favorable temperature existed. The program also accounts for the effect of the incidence angle of insolation and the effect of the number of glass plates on the transmittance and absorptance of the collector and windows. Other refinements include: the use of a sophisticated nighttime setback thermostat, account of internal heat generation and infiltration loss. Among all of the parameter variations, the use of an attic heat exchanger resulted in the maximum savings in the heating/cooling energy consumption of the house. The use of double-glazed windows too, resulted in substantial energy savings. The total energy consumption was found to depend strongly on the infiltration rate. The program was also used to simulate the same system under weather conditions existing at several different geographic areas.

  20. Research and Development of a Low Cost Solar Collector

    Energy Technology Data Exchange (ETDEWEB)

    Ansari, Asif; Philip, Lee; Thouppuarachchi, Chirath

    2012-08-01

    This is a Final Technical Report on the Research and Development completed towards the development of a Low Cost Solar Collector conducted under the DOE cost-sharing award EE-0003591. The objective of this project was to develop a new class of solar concentrators with geometries and manufacturability that could significantly reduce the fully installed cost of the solar collector field for concentrated solar thermal power plants. The goal of the project was to achieve an aggressive cost target of $170/m2, a reduction of up to 50% in the total installed cost of a solar collector field as measured against the current industry benchmark of a conventional parabolic trough. The project plan, and the detailed activities conducted under the scope of the DOE Award project addressed all major drivers that affect solar collector costs. In addition to costs, the study also focused on evaluating technical performance of new collector architectures and compared them to the performance of the industry benchmark parabolic trough. The most notable accomplishment of this DOE award was the delivery of a full-scale integrated design, manufacturing and field installation solution for a new class of solar collector architecture which has been classified as the Bi-Planar Fresnel Collector (BPFC) and may be considered as a viable alternative to the conventional parabolic trough, as well as the conventional Fresnel collectors. This was in part accomplished through the design and development, all the way through fabrication and test validation of a new class of Linear Planar Fresnel Collector architecture. This architecture offers a number of key differentiating features which include a planar light-weight frame geometry with small mass-manufacturable elements utilizing flat mirror sections. The designs shows significant promise in reducing the material costs, fabrication costs, shipping costs, and on-site field installation costs compared to the benchmark parabolic trough, as well as the

  1. The sizes of Flat Plate and Evacuated Tube Collectors with Heat Pipe area as a function of the share of solar system in the heat demand

    Directory of Open Access Journals (Sweden)

    Olek Małgorzata

    2016-01-01

    Full Text Available The popularity of solar collectors in Poland is still increasing. The correct location of the collectors and a relatively high density of solar radiation allow delivering heat even in spite of relatively low ambient temperature. Moreover, solar systems used for heating domestic heat water (DHW in summer allow nearly complete elimination of conventional energy sources (e.g. gas, coal. That is why more and more house owners in Poland decide to install solar system installations. In Poland the most common types of solar collectors are flat plate collectors (FPC and evacuated tube collectors with heat pipe (ETCHP; both were selected for the analysis. The heat demand related to the preparation of hot water, connected with the size of solar collectors’ area, has been determined. The analysis includes FPC and ETCHP and heat demand of less than 10 000 kWh/year. Simulations were performed with the Matlab software and using data from a typical meteorological year (TMY. In addition, a 126–year period of measurements of insolation for Krakow has been taken into account. The HDKR model (Hay, Davis, Klucher, Reindl was used for the calculation of solar radiation on the absorber surface. The monthly medium temperature of the absorber depends on the amount of solar system heat and on the heat demand. All the previously mentioned data were used to determine solar efficiency. Due to the fact that solar efficiency and solar system heat are connected, the calculations were made with the use of an iterative method. Additionally, the upper limit for monthly useful solar system heat is resulted from the heat demand and thus the authors prepared a model of statistical solar system heat deviations based on the Monte Carlo method. It has been found that an increase in the useful solar system heat in reference to the heat demand is associated with more than proportional increase in the sizes of the analyzed surfaces of solar collector types.

  2. Lightweight diaphragm mirror module system for solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Butler, B. L.

    1985-04-16

    A mirror module system is provided for accurately focusing solar radiation on a point or a line as defined by an array of solar collectors. Each mirror module includes a flexible membrane stretched over a frame in a manner similar to that of a drum or a trampoline and further includes a silvered glass or plastic mirror for forming an optical reflecting surface. The configuration of the optical reflecting surface is variably adjustable to provide for the accurate focusing of the solar energy on a given collector array, e.g., a point or a linear array arrangement. The flexible mirror-membrane combination is lightweight to facilitate installation and reduce system cost yet structurally strong enough to provide for the precise focusing of the incident solar radiation in a semi-rigid reflector system in which unwanted reflector displacement is minimized.

  3. Lightweight diaphragm mirror module system for solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Butler, Barry L. (Golden, CO)

    1985-01-01

    A mirror module system is provided for accurately focusing solar radiation on a point or a line as defined by an array of solar collectors. Each mirror module includes a flexible membrane stretched over a frame in a manner similar to that of a drum or a trampoline and further includes a silvered glass or plastic mirror for forming an optical reflecting surface. The configuration of the optical reflecting surface is variably adjustable to provide for the accurate focusing of the solar energy on a given collector array, e.g., a point or a linear array arrangement. The flexible mirror-membrane combination is lightweight to facilitate installation and reduce system cost yet structurally strong enough to provide for the precise focusing of the incident solar radiation in a semi-rigid reflector system in which unwanted reflector displacement is minimized.

  4. Lightweight diaphragm mirror module system for solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Butler, B.L.

    1984-01-01

    A mirror module system is provided for accurately focusing solar radiation on a point or a line as defined by an array of solar collectors. Each mirror module includes a flexible membrane stretched over a frame in a manner similar to that of a drum or a trampoline and further includes a silvered glass or plastic mirror for forming an optical reflecting surface. The configuration of the optical reflecting surface is variably adjustable to provide for the accurate focusing of the solar energy on a given collector array, e.g., a point or a linear array arrangement. The flexible mirror-membrane combination is lightweight to facilitate installation and reduce system cost yet structurally strong enough to provide for the precise focusing of the incident solar radiation in a semi-rigid reflector system in which unwanted reflector displacement is minimized.

  5. Investigation of Backside Textures for Genesis Solar Wind Silicon Collectors

    Science.gov (United States)

    Gonzalez, C. P.; Burkett, P. J.; Rodriguez, M. C.; Allton, J. H.

    2014-01-01

    Genesis solar wind collectors were comprised of a suite of 15 types of ultrapure materials. The single crystal, pure silicon collectors were fabricated by two methods: float zone (FZ) and Czochralski (CZ). Because of slight differences in bulk purity and surface cleanliness among the fabrication processes and the specific vendor, it is desirable to know which variety of silicon and identity of vendor, so that appropriate reference materials can be used. The Czochralski method results in a bulk composition with slightly higher oxygen, for example. The CZ silicon array wafers that were Genesis-flown were purchased from MEMC Electronics. Most of the Genesis-flown FZ silicon was purchased from Unisil and cleaned by MEMC, although a few FZ wafers were acquired from International Wafer Service (IWS).

  6. Bilinear reduced order approximate model of parabolic distributed solar collectors

    KAUST Repository

    Elmetennani, Shahrazed

    2015-07-01

    This paper proposes a novel, low dimensional and accurate approximate model for the distributed parabolic solar collector, by means of a modified gaussian interpolation along the spatial domain. The proposed reduced model, taking the form of a low dimensional bilinear state representation, enables the reproduction of the heat transfer dynamics along the collector tube for system analysis. Moreover, presented as a reduced order bilinear state space model, the well established control theory for this class of systems can be applied. The approximation efficiency has been proven by several simulation tests, which have been performed considering parameters of the Acurex field with real external working conditions. Model accuracy has been evaluated by comparison to the analytical solution of the hyperbolic distributed model and its semi discretized approximation highlighting the benefits of using the proposed numerical scheme. Furthermore, model sensitivity to the different parameters of the gaussian interpolation has been studied.

  7. Application of Induction Heating for Brazing Parts of Solar Collectors

    Directory of Open Access Journals (Sweden)

    Kristína Demianová

    2012-01-01

    Full Text Available This paper reports on the application of induction heating for brazing parts of solar collectors made of Al alloys. The tube-flange joint is a part of the collecting pipe of a solar collector. The main task was to design an induction coil for this type of joint, and to select the optimum brazing parameters. Brazing was performed with AlSi12 brazing alloy, and corrosive and non-corrosive flux types were also applied. The optimum brazing parameters were determined on the basis of testing the fabricated brazed joints by visual inspection, by leakage tests, and by macro- and micro-analysis of the joint boundary. The following conditions can be considered to be the best for brazing Al materials: power 2.69 kW,brazing time 24 s, flux BrazeTec F32/80.

  8. Water heating solar system using collector with polycarbonate absorber surface

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Luiz Guilherme Meira de; Sodre, Dilton; Cavalcanti, Eduardo Jose Cidade; Souza, Luiz Guilherme Vieira Meira de; Mendes, Jose Ubiragi de Lima [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil)], e-mails: lguilherme@dem.ufrn.br, diltonsodre@ifba.edu.br, ubiragi@ct.ufrn.br

    2010-07-01

    It is presented s solar collector to be used in a heating water for bath system, whose main characteristics are low cost and easy fabrication and assembly processes. The collector absorber surface consists of a polycarbonate plate with an area of 1.5 m{sup 2}. The water inlet and outlet are made of PVC 50mm, and were coupled to a 6mm thick polycarbonate plate using fiberglass resin. A 200 liters thermal reservoir will be used. This reservoir is also alternative. The absorber heating system works under thermo-siphon regimen. Thermal parameters will be evaluated to prove the feasibility of the studied solar heating system to obtain bath water for a four people family. (author)

  9. IMPACT OF SOLAR RADIATION CHANGE ON THE COLLECTOR EFFICIENTLY

    Directory of Open Access Journals (Sweden)

    Danuta Proszak-Miąsik

    2017-01-01

    Full Text Available In October 2014 in a building of Rzeszow University of Technology, a series of measurements was taken to calculate the parameters of a solar system with a flat collector, as installed on the roof of the building. The following parameters were obtained: the value of solar radiation intensity, the temperature of external air, the temperature on the collector, the temperature of water in the tank and the temperature of glycol on the supply and return lines. On the basis of the data received, charts were made to visually present how changes of solar radiation intensity affected parameters of the system. The study was conducted in autumn when the intensity of solar radiation decreases, compared with summer months. The publication aims to show that the solar system brings energy gains in periods of transition, and the instantaneous intensity of solar radiation are comparable to those in the summer.

  10. Evaluation of Surface Slope Irregularity in Linear Parabolic Solar Collectors

    Directory of Open Access Journals (Sweden)

    F. Francini

    2012-01-01

    Full Text Available The paper describes a methodology, very simple in its application, for measuring surface irregularities of linear parabolic collectors. This technique was principally developed to be applied in cases where it is difficult to use cumbersome instruments and to facilitate logistic management. The instruments to be employed are a digital camera and a grating. If the reflector surface is defective, the image of the grating, reflected on the solar collector, appears distorted. Analyzing the reflected image, we can obtain the local slope of the defective surface. These profilometric tests are useful to identify and monitor the mirror portions under mechanical stress and to estimate the losses caused by the light rays deflected outside the absorber.

  11. A low cost high temperature sun tracking solar energy collector

    Science.gov (United States)

    Perkins, G. S.

    1977-01-01

    The design and economic evaluation of a low cost high temperature two axis sun tracking solar energy collector are described. The collector design is specifically intended for solar energy use with the freedom of motion about its two control axes being limited only to the amplitude required to track the sun. An examination of the performance criteria required in order to track the sun and perform the desired solar energy conversion is used as the starting point and guide to the design. This factor, along with its general configuration and structural aspect ratios, is the significant contributor to achieving low cost. The unique mechanical design allows the control system to counter wide tolerances that will be specified for the fabrication of the azimuth frame and perform within a small tracking error.

  12. Thermal advantage of tracking solar collectors under Danish weather conditions

    DEFF Research Database (Denmark)

    Andersen, Elsa; Dragsted, Janne; Furbo, Simon

    2010-01-01

    Theoretical investigations have been carried out with the aim to elucidate the thermal advantage of tracking solar collectors for different weather conditions in Kgs. Lyngby, Denmark (55.8°N), and for the weather conditions in Sisimiut, Greenland (66.9°N), just north of the arctic circle....... The investigations are based on calculations with a newly developed program. Measured weather data from a solar radiation measurement station at Technical University of Denmark in Kgs. Lyngby Denmark in the period 1990 to 2002 and the Danish Design Reference Year, DRY data file are used in the investigations....... The weather data used for Sisimiut are based on a Test Reference Year, TRY weather data file. The thermal advantages of different tracking strategies is investigated for two flat plate solar collectors with different efficiencies, operated at different temperature levels. The investigations show...

  13. Parabolic-trough solar collectors and their applications

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Garcia, A.; Zarza, E.; Valenzuela, L. [CIEMAT-Plataforma Solar de Almeria, Ctra. Senes, km. 4, Tabernas (Almeria) 04200 (Spain); Perez, M. [Departamento de Fisica Aplicada, Universidad de Almeria, Almeria 04120 (Spain)

    2010-09-15

    This paper presents an overview of the parabolic-trough collectors that have been built and marketed during the past century, as well as the prototypes currently under development. It also presents a survey of systems which could incorporate this type of concentrating solar system to supply thermal energy up to 400 C, especially steam power cycles for electricity generation, including examples of each application. (author)

  14. Performance Simulation Comparison for Parabolic Trough Solar Collectors in China

    Directory of Open Access Journals (Sweden)

    Jinping Wang

    2016-01-01

    Full Text Available Parabolic trough systems are the most used concentrated solar power technology. The operating performance and optical efficiency of the parabolic trough solar collectors (PTCs are different in different regions and different seasons. To determine the optimum design and operation of the parabolic trough solar collector throughout the year, an accurate estimation of the daily performance is needed. In this study, a mathematical model for the optical efficiency of the parabolic trough solar collector was established and three typical regions of solar thermal utilization in China were selected. The performance characteristics of cosine effect, shadowing effect, end loss effect, and optical efficiency were calculated and simulated during a whole year in these three areas by using the mathematical model. The simulation results show that the optical efficiency of PTCs changes from 0.4 to 0.8 in a whole year. The highest optical efficiency of PTCs is in June and the lowest is in December. The optical efficiency of PTCs is mainly influenced by the solar incidence angle. The model is validated by comparing the test results in parabolic trough power plant, with relative error range of 1% to about 5%.

  15. Macroscopic Subdivision of Silica Aerogel Collectors for Sample Return Missions

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, H A; Bradley, J P

    2005-09-14

    Silica aerogel collector tiles have been employed for the collection of particles in low Earth orbit and, more recently, for the capture of cometary particles by NASA's Stardust mission. Reliable, reproducible methods for cutting these and future collector tiles from sample return missions are necessary to maximize the science output from the extremely valuable embedded particles. We present a means of macroscopic subdivision of collector tiles by generating large-scale cuts over several centimeters in silica aerogel with almost no material loss. The cut surfaces are smooth and optically clear allowing visual location of particles for analysis and extraction. This capability is complementary to the smaller-scale cutting capabilities previously described [Westphal (2004), Ishii (2005a, 2005b)] for removing individual impacts and particulate debris in tiny aerogel extractions. Macroscopic cuts enable division and storage or distribution of portions of aerogel tiles for immediate analysis of samples by certain techniques in situ or further extraction of samples suited for other methods of analysis.

  16. Assessment of existing studies of wind loading on solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, L. M.

    1981-02-01

    In developing solar collectors, wind loading is the major structural design consideration. Wind loading investigations have focused on establishing safe bounds for steady state loading and verifying rational but initial and conservative design approaches for the various solar collector concepts. As such, the effort has been very successful, and has contributed greatly to both the recognition and qualitative understanding of many of the physical phenomena involved. Loading coefficients corresponding to mean wind velocities have been derived in these prior studies to measure the expected structural loading on the various solar collectors. Current design and testing procedures for wind loading are discussed. The test results corresponding to numerous wind tests on heliostats, parabolic troughs, parabolic dishes, and field mounted photovoltaic arrays are discussed and the applicability of the findings across the various technologies is assessed. One of the most significant consistencies in the data from all the technologies is the apparent benefit provided by fences and field shielding. Taken in toto, these data show that load reductions of three or possibly more seem feasible, though a more thorough understanding of the phenomena involved must be attained before this benefit can be realized. It is recommended that the required understanding be developed to take advantage of this benefit and that field tests be conducted to correlate with both analyses and tests.

  17. Hybrid solar collector using nonimaging optics and photovoltaic components

    Science.gov (United States)

    Winston, Roland; Yablonovitch, Eli; Jiang, Lun; Widyolar, Bennett K.; Abdelhamid, Mahmoud; Scranton, Gregg; Cygan, David; Kozlov, Alexandr

    2015-08-01

    The project team of University of California at Merced (UC-M), Gas Technology Institute, and Dr. Eli Yablonovitch of University of California at Berkeley developed a novel hybrid concentrated solar photovoltaic thermal (PV/T) collector using nonimaging optics and world record single-junction Gallium arsenide (GaAs) PV components integrated with particle laden gas as thermal transfer and storage media, to simultaneously generate electricity and high temperature dispatchable heat. The collector transforms a parabolic trough, commonly used in CSP plants, into an integrated spectrum-splitting device. This places a spectrum-sensitive topping element on a secondary reflector that is registered to the thermal collection loop. The secondary reflector transmits higher energy photons for PV topping while diverting the remaining lower energy photons to the thermal media, achieving temperatures of around 400°C even under partial utilization of the solar spectrum. The collector uses the spectral selectivity property of Gallium arsenide (GaAs) cells to maximize the exergy output of the system, resulting in an estimated exergy efficiency of 48%. The thermal media is composed of fine particles of high melting point material in an inert gas that increases heat transfer and effectively stores excess heat in hot particles for later on-demand use.

  18. Thin-film absorber for a solar collector

    Energy Technology Data Exchange (ETDEWEB)

    Wilhelm, W.G.

    1982-02-09

    This invention pertains to energy absorbers for solar collectors, and more particularly to high performance thin film absorbers. The solar collectors comprising the absorber of this invention overcome several problems seen in current systems, such as excessive hardware, high cost and unreliability. In the preferred form, the apparatus features a substantially rigid planar frame with a thin film window bonded to one planar side of the frame. An absorber in accordance with the present invention is comprised of two thin film layers that are sealed perimetrically. In a preferred embodiment, thin film layers are formed from a metal/plastic laminate. The layers define a fluid-tight planar envelope of large surface area to volume through which a heat transfer fluid flows. The absorber is bonded to the other planar side of the frame. The thin film construction of the absorber assures substantially full envelope wetting and thus good efficiency. The window and absorber films stress the frame adding to the overall strength of the collector.

  19. Grid Collector: Facilitating Efficient Selective Access from DataGrids

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Kesheng; Gu, Junmin; Lauret, Jerome; Poskanzer, Arthur M.; Shoshani, Arie; Sim, Alexander; Zhang, Wei-Ming

    2005-05-17

    The Grid Collector is a system that facilitates the effective analysis and spontaneous exploration of scientific data. It combines an efficient indexing technology with a Grid file management technology to speed up common analysis jobs on high-energy physics data and to enable some previously impractical analysis jobs. To analyze a set of high-energy collision events, one typically specifies the files containing the events of interest, reads all the events in the files, and filters out unwanted ones. Since most analysis jobs filter out significant number of events, a considerable amount of time is wasted by reading the unwanted events. The Grid Collector removes this inefficiency by allowing users to specify more precisely what events are of interest and to read only the selected events. This speeds up most analysis jobs. In existing analysis frameworks, the responsibility of bringing files from tertiary storages or remote sites to local disks falls on the users. This forces most of analysis jobs to be performed at centralized computer facilities where commonly used files are kept on large shared file systems. The Grid Collector automates file management tasks and eliminates the labor-intensive manual file transfers. This makes it much easier to perform analyses that require data files on tertiary storages and remote sites. It also makes more computer resources available for analysis jobs since they are no longer bound to the centralized facilities.

  20. Ultraviolet out-of-band radiation studies in laser tin plasma sources

    Science.gov (United States)

    Parchamy, Homaira; Szilagyi, John; Masnavi, Majid; Richardson, Martin

    2017-11-01

    Out-of-band long wavelength emission measurements from high power, high-repetition-rate extreme-ultra-violet lithography (EUVL) laser plasma sources are imperative to estimating heat deposition in EUV mirrors, and the impact of short wavelength light transported through the imaging system to the wafer surface. This paper reports a series of experiments conducted to measure the absolute spectral irradiances of laser-plasmas produced from planar tin targets over the wavelength region of 124 to 164 nm by 1.06 μm wavelength, 10 ns full-width-at-half-maximum Gaussian laser pulses. The use of spherical targets is relevant to the EUVL source scenario. Although plasmas produced from planar surfaces evolve differently, there is a close similarity to the evolution of current from 10.6 μm CO2 laser EUVL sources, which use a pre-pulse from a lower energy solid-state laser to melt and reform an initial spherical droplet into a thin planar disc target. The maximum of radiation conversion efficiency in the 124-164 nm wavelength band (1%/2πsr) occurs at the laser intensity of 1010 W cm-2. A developed collisional-radiative model reveals the strong experimental spectra that originate mainly from the 4d105p2-4d105s5p, 4d105p-4d105s resonance lines, and 4d95p-4d95s unresolved transition arrays from Sn III, Sn IV, and Sn V ions, respectively. The calculated conversion efficiencies using a 2D radiation-hydrodynamics model are in agreement with the measurements. The model predicts the out-of-band (100-400 nm) radiation conversion efficiencies generated by both 1.06 and 10.6 μm pulses. The 10.6 μm laser pulse produces a higher conversion efficiency (12%/2πsr) at the lower laser intensity of 109 W cm-2.

  1. Lifetime of solar collectors in solar heating plants; Levetid for solfangere i solvarmecentraler

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Z.; Fan, J.; Perers, B.; Furbo, S.

    2009-10-15

    Two HT solar collectors, which have been in operation at high temperature levels in Ottrupgaard solar heating plant for 15 years and in Marstal solar heating plant for 13 years, were in the spring of 2009 tested with regard to efficiency. The collectors were also inspected with the aim to evaluate the life time of the collectors. An old version of the HT solar collector, which has been in operation in a Swedish test facility since 1982, was tested with regard to the thermal performance. The measurements showed that the efficiencies of the solar collectors from the two Danish solar heating plants have been decreased since the installation. The reductions of the yearly thermal performance of the solar collectors are at a temperature level of 40 centigrade Celsius, 1% and 4%, respectively, for the Marstal collector and the Ottrupgaard collector. At a temperature level of 60 centigrade Celsius the reduction of the yearly thermal performance is 10% and 11%, respectively, for the Marstal collector and the Ottrupgaard collector. At a temperature level of 80 centigrade Celsius the reduction is 27% and 23%, respectively, for the Marstal collector and the Ottrupgaard collector. Based on the inspection, it is estimated that the reason for the reduction of thermal performance is the condition of the Teflon foil and the installation of the Teflon foil. The Teflon foil is wrinkled and folded and expanded in such a way that the distance between the absorber and the Teflon foil is far too small. Further, cracks in the Teflon foil have been observed. The thermal performance of the Swedish solar collector in the test facility is after 26 years of operation reduced compared to the thermal performance of the collector when it was first installed. For this collector the reduction in thermal performance is only 2-5%. The collectors from Ottrupgaard solar heating plant and from Marstal solar heating plant were in a very good condition with exception of the above mentioned problems with

  2. Theoretical analysis to investigate thermal performance of co-axial heat pipe solar collector

    Science.gov (United States)

    Azad, E.

    2011-12-01

    The thermal performance of co-axial heat pipe solar collector which consist of a collector 15 co-axial heat pipes surrounded by a transparent envelope and which heat a fluid flowing through the condenser tubes have been predicted using heat transfer analytical methods. The analysis considers conductive and convective losses and energy transferred to a fluid flowing through the collector condenser tubes. The thermal performances of co-axial heat pipe solar collector is developed and are used to determine the collector efficiency, which is defined as the ratio of heat taken from the water flowing in the condenser tube and the solar radiation striking the collector absorber. The theoretical water outlet temperature and efficiency are compared with experimental results and it shows good agreement between them. The main advantage of this collector is that inclination of collector does not have influence on performance of co-axial heat pipe solar collector therefore it can be positioned at any angle from horizontal to vertical. In high building where the roof area is not enough the co-axial heat pipe solar collectors can be installed on the roof as well as wall of the building. The other advantage is each heat pipe can be topologically disconnected from the manifold.

  3. On the Influence of Collector Size on the Solar Chimneys Performance

    Directory of Open Access Journals (Sweden)

    Al-Azawiey Sundus S.

    2017-01-01

    Full Text Available Performance of solar chimney power plant system is highly influenced by the design geometries. The collector size is logically enhances the solar chimney performance, but the trend of enhancement is not yet investigated. In the present work, experimental and numerical investigations have been carried out to ascertain, in terms of qualitative and quantitative evaluation, the effect of the collector diameter. Daily thermal efficiency has been determined at four different collector diameter. Two different collector diameters, 3.0 and 6.0 m, have been investigated experimentally, and then scaled up, to 9.0 and 12.0 m, by numerical simulation using ANSYS-FLUENT®15 software. Results demonstrated that collector diameter has effectively influenced the system performance. Larger collector diameter imposed increase in the velocity, temperature and the daily average thermal efficiency of the system. From the experimental results, increasing the collector diameter from 3.0 to 6.0 m has increased the daily average thermal efficiency of the collector from 9.81 to 12.8. Simulation results at 800 W/m2 irradiation revealed that the velocity in the chimney have increased from 1.66 m/s at 3.0 m collector diameter to 2.34, 2.47 and 2.63 m/s for 6.0, 9.0 and 12.0 m collector diameters, respectively.

  4. Wetting properties and performance test of modified rigid collector in wet electrostatic precipitators.

    Science.gov (United States)

    Xu, Chunyan; Chang, Jingcai; Meng, Zhen; Wang, Xiang; Zhang, Jing; Cui, Lin; Ma, Chunyuan

    2016-10-01

    The fine particles are considered a significant pollution problem. The wet electrostatic precipitators (ESPs) have advantages of efficient collection of the fine particles with lower pressure drop and eliminating reentrainment. The wetting properties of the collector surfaces have significantly important effect on wet ESPs' stable and secure operation. The modified rigid collector (MRC) was modified by coating specific vinyl ester resin composites and loose glass fiber cloth over the conventional carbon steel in a certain way. The rigid collector surfaces before and after modification had been characterized by scanning electron microscopy (SEM) and interface tensiometer. The effect of operating temperatures on the wetting properties of the rigid collector surfaces before and after modification was investigated. The temperature range was 40~90 °C, and the wetting properties contained liquid holdup, surface flow rate, film rate, average film thickness, and critical saturation time. The modified rigid collector surface exhibited excellent wetting properties at the operating temperatures. The fine particles collection performance compared among the MRC, the conventional rigid collector (CRC), and the flexible collector (FC) in the wet ESPs was investigated. The effects of the applied voltage, the water film, corona power, and the specific collecting area on the fine particles collection were evaluated. The modified rigid collector provided high fine particles collection effect with lower energy and water consumption. To improve the submicron particles collection efficiency and decrease energy and water consumption, the formation of uniform water film over the collector surfaces has been widely studied. The modified rigid collector was modified by coating specific vinyl ester resin composites and loose glass fiber cloth (ERGF) over the conventional carbon steel (CCS) in a certain way. The modified rigid collector surface exhibited excellent wetting properties. The wet

  5. Laboratory demonstration of image reconstruction for coherent optical system of modular imaging collectors (COSMIC)

    Science.gov (United States)

    Traub, W. A.

    1984-01-01

    The first physical demonstration of the principle of image reconstruction using a set of images from a diffraction-blurred elongated aperture is reported. This is an optical validation of previous theoretical and numerical simulations of the COSMIC telescope array (coherent optical system of modular imaging collectors). The present experiment utilizes 17 diffraction blurred exposures of a laboratory light source, as imaged by a lens covered by a narrow-slit aperture; the aperture is rotated 10 degrees between each exposure. The images are recorded in digitized form by a CCD camera, Fourier transformed, numerically filtered, and added; the sum is then filtered and inverse Fourier transformed to form the final image. The image reconstruction process is found to be stable with respect to uncertainties in values of all physical parameters such as effective wavelength, rotation angle, pointing jitter, and aperture shape. Future experiments will explore the effects of low counting rates, autoguiding on the image, various aperture configurations, and separated optics.

  6. A numerical model to evaluate the flow distribution in a large solar collector field

    DEFF Research Database (Denmark)

    Bava, Federico; Dragsted, Janne; Furbo, Simon

    2017-01-01

    This study presents a numerical model to evaluate the flow distribution in a large solar collector field, with solar collectors connected both in series and in parallel. The boundary conditions of the systems, such as flow rate, temperature, fluid type and layout of the collector field can...... be easily changed in the model. The model was developed in Matlab and the calculated pressure drop and flow distribution were compared with measurements from a solar collector field. A good agreement between model and measurements was found. The model was then used to study the flow distribution...... in different conditions. Balancing valves proved to be an effective way to achieve uniform flow distribution also in conditions different from those for which the valves were regulated. For small solar collector fields with limited number of collector rows connected in parallel, balancing valves...

  7. Cleaning Surface Particle Contamination with Ultrapure Water (UPW) Megasonic Flow on Genesis Array Collectors

    Science.gov (United States)

    Allton, J. H.; Calaway, Michael J.; Hittle, J. D.; Rodriquez, M. C.; Stansbery, E. K.; McNamara, K. M.

    2006-01-01

    The hard landing experienced by the Genesis sample return capsule breached the science canister containing the solar wind collectors. This impact into the damp lakebed contaminated collector surfaces with pulverized collector and spacecraft materials and Utah sediment and brine residue. The gold foil, polished aluminum, and bulk metallic glass remained intact, but the solar wind bulk and regime-specific array collectors were jarred loose from their frames and fractured into greater than 10,000 specimens. After a year of investigation and cleaning experimentation, the Genesis Science Team determined that array collectors had 4 classes of contaminants: particles, molecular film, submicron inorganic particulate ("aerosol"), and pre-launch surface contamination. We discuss here use of megasonically energized ultrapure water (UPW) for removing particulate debris from array collector fragments.

  8. Flow distribution in a solar collector panel with horizontally inclined absorber strips

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    2007-01-01

    The objective of this work is to theoretically and experimentally investigate the flow and temperature distribution in a solar collector panel with an absorber consisting of horizontally inclined strips. Fluid flow and heat transfer in the collector panel are studied by means of computational fluid...... dynamics (CFD) calculations. Further, experimental investigations of a 12.5 m(2) solar collector panel with 16 parallel connected horizontal fins are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the backside of the absorber tubes. The measured...... rate, properties of solar collector fluid, solar collector fluid inlet temperature and collector tilt angle are shown. The flow distribution through the absorber fins is uniform if high flow rates are used. By decreased flow rate and decreased content of glycol in the glycol/water mixture used as solar...

  9. Comparison of Thermal Performances of Fixed and Tracking Solar Collectors With Computational Fluid Dynamics

    OpenAIRE

    Keçel, Selçuk

    2015-01-01

    Solar collectors, one of the important areas of use for solar power, are based on the principle of heating water flowing through piping systems with solar radiation. Collectors are mostly fixed with various constructions on roofs of buildings, which provide hot water. Efficiency differences between fixed systems and tracking systems are generally compared over efficiencies of photovoltaic systems. As a different this study, the thermal analysis of solar collector systems to be installed on tw...

  10. Penggunaan Heat Pipe Persegi Dan Sirip Untuk Meningkatkan Performance Pada Flat Plate Solar Collector

    OpenAIRE

    Adawiyah, Rabiatul; Arifin, M. Khafidz

    2016-01-01

    Based on the review of references from journals, and review of the literature supportingthis research, state of art the underlying issue of solar collectors in particular types of flatplate solar collector how to improve performance such as efficiency the collector can beincreased maximum. In improving this performance history researchers perform a variety ofways, that is modification, add fixtures, test material used etc. From the results of researchrelated to the problem of the increase in ...

  11. Indoor test for thermal performance of the Sunmaster evacuated tube (liquid) solar collector

    Science.gov (United States)

    1979-01-01

    The test procedures used to obtain the thermal performance data for a solar collector under simulated conditions are presented. Tests included a stagnation test, a time constant test, a thermal efficiency test, an incident angle modifier test, and a hot fill test. All tests were performed at ambient conditions and the transient effect and the incident angle effect on the collector were determined. The solar collector is a water working fluid type.

  12. Semi-solid electrode cell having a porous current collector and methods of manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Chiang, Yet-Ming; Carter, William Craig; Cross, III, James C.; Bazzarella, Ricardo; Ota, Naoki

    2017-11-21

    An electrochemical cell includes an anode, a semi-solid cathode, and a separator disposed therebetween. The semi-solid cathode includes a porous current collector and a suspension of an active material and a conductive material disposed in a non-aqueous liquid electrolyte. The porous current collector is at least partially disposed within the suspension such that the suspension substantially encapsulates the porous current collector.

  13. Development of flat-plate solar collectors for the heating and cooling of buildings: Executive summary

    Science.gov (United States)

    1978-01-01

    An efficient, low cost, flat-plate solar collector was developed. Computer aided mathematical models of the heat process in the collector were used in defining absorber panel configuration; determining insulation thickness; and in selecting the number, spacing, and material of the covers. Prototypes were built and performance tested. Data from simulated operation of the collector are compared with predicted loads from a number of locations to determine the degree of solar utilization.

  14. Measurement of in situ sulfur isotopes by laser ablation multi-collector ICPMS: opening Pandora’s Box

    Science.gov (United States)

    Ridley, William I.; Pribil, Michael; Koenig, Alan E.; Slack, John F.

    2015-01-01

    Laser ablation multi-collector ICPMS is a modern tool for in situ measurement of S isotopes. Advantages of the technique are speed of analysis and relatively minor matrix effects combined with spatial resolution sufficient for many applications. The main disadvantage is a more destructive sampling mechanism relative to the ion microprobe technique. Recent advances in instrumentation allow precise measurement with spatial resolutions down to 25 microns. We describe specific examples from economic geology where increased spatial resolution has greatly expanded insights into the sources and evolution of fluids that cause mineralization and illuminated genetic relations between individual deposits in single mineral districts.

  15. Wind effects on collectors. Final report, October 1, 1978--October 1, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Hewitt, H.C. Jr.; Griggs, E.I.

    1979-11-01

    Consideration was given to modeling wind speed data and to a scheme for correlating data between two separate stations. A sensor system was developed to measure the effect of wind on collector performance. The specifications for the sensor are presented, and a discussion of the calibration of the sensor is given. Four experiments were performed to determine wind flow patterns around buildings. The velocity profile over an actual collector was also measured as a function of free stream velocity. A mathematical model for a solar collector and three experimental efforts to measure the effect of wind on collector performance are reported. (MHR)

  16. Effect of Glass Thickness on Performance of Flat Plate Solar Collectors for Fruits Drying

    Directory of Open Access Journals (Sweden)

    Ramadhani Bakari

    2014-01-01

    Full Text Available This study aimed at investigating the effect of thickness of glazing material on the performance of flat plate solar collectors. Performance of solar collector is affected by glaze transmittance, absorptance, and reflectance which results into major heat losses in the system. Four solar collector models with different glass thicknesses were designed, constructed, and experimentally tested for their performances. Collectors were both oriented to northsouth direction and tilted to an angle of 10° with the ground toward north direction. The area of each collector model was 0.72 m2 with a depth of 0.15 m. Low iron (extra clear glass of thicknesses 3 mm, 4 mm, 5 mm, and 6 mm was used as glazing materials. As a control, all collector performances were analysed and compared using a glass of 5 mm thickness and then with glass of different thickness. The results showed that change in glass thickness results into variation in collector efficiency. Collector with 4 mm glass thick gave the best efficiency of 35.4% compared to 27.8% for 6 mm glass thick. However, the use of glass of 4 mm thick needs precautions in handling and during placement to the collector to avoid extra costs due to breakage.

  17. Efficiency enhancement of octave-bandwidth traveling wave tubes by use of multistage depressed collectors

    Science.gov (United States)

    Ramins, P.; Fox, T. A.

    1979-01-01

    Small, three- and five-stage depressed collectors were evaluated in conjunction with a 4.8- to 9.6-GHz TWT of 325- to 675-W power output and a beam of 0.5 microperv. The multistage depressed collector (MDC) performed well even though its design had been optimized for a TWT of identical design but considerably less output power. Despite large, fixed losses significant efficiency enhancement was demonstrated with both the three- and five-stage depressed collectors. At saturated rf power output, the improvement in the overall efficiency ranged from a factor of 2.5 to 3.0 for the three-stage collector and a factor of 3.0 to 3.5 for the five-stage collector. At saturation three-stage collector efficiencies of 77 to 80 percent and five-stage collector efficiencies of 81 to 84 percent were obtained across the frequency band. An overall efficiency of 37.0 to 44.3 percent across the frequency band of 4.8 to 9.6 GHz was demonstrated with the use of harmonic injection. For operation below saturation, even larger relative improvements in the overall TWT efficiency were demonstrated. Collector performance was relatively insensitive to the degree of regulation of the collector power supply.

  18. Simulations of geometry effects and loss mechanisms affecting the photon collection in photovoltaic fluorescent collectors

    Directory of Open Access Journals (Sweden)

    Rau U.

    2012-06-01

    Full Text Available Monte-Carlo simulations analyze the photon collection in photovoltaic systems with fluorescent collectors. We compare two collector geometries: the classical setup with solar cells mounted at each collector side and solar cells covering the collector back surface. For small ratios of collector length and thickness, the collection probability of photons is equally high in systems with solar cells mounted on the sides or at the bottom of the collector. We apply a photonic band stop filter acting as an energy selective filter which prevents photons emitted by the dye from leaving the collector. We find that the application of such a filter allows covering only 1% of the collector side or bottom area with solar cells. Furthermore, we compare ideal systems in their radiative limits to systems with included loss mechanisms in the dye, at the mirror, or the photonic filter. Examining loss mechanisms in photovoltaic systems with fluorescent collectors enables us to estimate quality limitations of the used materials and components.

  19. NUMERICAL SIMULATION OF THE AIR FLOW AROUND THE ARRAYS OF SOLAR COLLECTORS

    Directory of Open Access Journals (Sweden)

    Vukman V Bakić

    2011-01-01

    Full Text Available This paper deals with the numerical simulation of air around the arrays of flat plate collectors and determination of the flow field, which should provide a basis for estimating a convective heat losses, a parameter which influences their working characteristics. Heat losses are the result of the reflection on the glass, conductive losses at the collector's absorber plate, radiation of the absorber plate and convective losses on the glass. Wind velocity in the vicinity of the absorber plate depends on its position in the arrays of collectors. Results obtained in the numerical simulation of flow around collectors were used as boundary conditions in modeling of thermal-hydraulic processes inside the solar collector. A method for coupling thermal-hydraulic processes inside the collector with heat transfer from plate to tube bundle was developed, in order to find out the distribution of the temperature of the absorber plate and the efficiency of the flat plate collectors. Analyses of flow around arrays of collectors are preformed with RNG k - ε model. Three values for free-stream velocity were analysed, i.e. 1 m/s, 5 m/s and 10 m/s, as well as two values for the angle between the ground and the collector (20° and 40°. Heat transfer coefficient was determined from the theory of boundary layer. Heat transfer inside the plate cavity was analyzed assuming constant intensity of radiation.

  20. A diagram for defined flat plate solar collector area for solar floor heating

    Energy Technology Data Exchange (ETDEWEB)

    Altuntop, N.; Tekin, Y. [Erciyes University, Dept. of Mechanical Engineering (Turkey); Cengel, Y.A. [Nevada Reno University, Dept. of Mechanical Engineering, NV (United States)

    2000-07-01

    In winters, one of the best ways to heat living areas by using the low- temperature - water obtained from flat-plate solar collectors is the floor heating. In floor heating, low temperature-water (30 + 60 deg C) can be used and heat can be stored in water when solar radiation is not possible. In this study, it is aimed to define collector surface needed to supply heat for floor heating. It is also aimed to define and explain the diagram developed for every heating months. The calculations about the sun geometry are used to define the amount of radiation coming in to the collectors. Formulations are made about the definition of solar radiation absorbed by the collectors, the total heat loss coefficient, and the collector plate surface temperature. These formulations are transformed in to the diagram. In addition, the studies, heat transfer calculations and design parameters about the floor of the heating areas are used. A combined collector floor heating diagram is obtained. This diagram is used to define collector surface area necessary to supply heat for floor heated places. In this diagram, the collector surface area is obtained by giving the heat capacity of the place area, floor surface temperature, approximate modulation distance of the floor, the elevation of city, collector slope angle, wind speed, sun shine lime and the amount of the solar radiation obtained from the solar radiation diagram. (authors)

  1. Hybrid Direct Carbon Fuel Cell Performance with Anode Current Collector Material

    DEFF Research Database (Denmark)

    Deleebeeck, Lisa; Kammer Hansen, Kent

    2015-01-01

    The influence of the current collector on the performance of a hybrid direct carbon fuel cell (HDCFC), consisting of solid oxide fuel cell (SOFC) with a molten carbonate-carbon slurry in contact with the anode, has been investigated using current-voltage curves. Four different anode current...... collectors were studied: Au, Ni, Ag, and Pt. It was shown that the performance of the direct carbon fuel cell (DCFC) is dependent on the current collector materials, Ni and Pt giving the best performance, due to their catalytic activity. Gold is suggested to be the best material as an inert current collector...

  2. Economical judge possibility uses solar collectors to warm service water and heating

    Directory of Open Access Journals (Sweden)

    Lívia Bodonská

    2006-09-01

    Full Text Available The sun-heated water has been used from before fossil fuels started to determine the direction of our power consumption. This article is focused on the assessing of the use of solar energy as one of inexhaustible resources that has multiple uses, including hot water service systems. Heating is rendered through solar collectors that permit to transform solar energy to warm water. We divide solar collectors into various groups but in principle they are medium temperature collectors and low temperature collectors. The work is directed also on the solar collector market. In our case the market is just at its initial stage as this technology is little known and costs of collectors are rather high, compared to our conditions, on average, they may grow up to 100,000 Slovac crowns per a family house. Because it is the only investment and the costs of operation are minimum throughout the entire collectors lifetime, from the economic point of view, it is a rather advantageous investment. Solar collectors are used in heating and also in hot service water systems in family houses, where they permit to lower costs for the consumption of many kinds of energies. In the hot service water system, solar collectors permit to lower the consumption by almost 70 %. This way of using the solar energy is very prospective and in future it will be used in various sectors

  3. Thermal Performance of Solar Hot Water Systems Using a Flat Plate Collector of Accelerated Risers

    Directory of Open Access Journals (Sweden)

    KE Amori

    2012-06-01

    Full Text Available This study focuses on a comparison of the performance of two similar locally-fabricated solar water heaters. One of the collectors features a new design for accelerated absorber; its risers are made of converging ducts whose exit area is half that of the entrance. The other collector is a conventional absorber, with risers of the same cross sectional area along its length. Each collector is the primary part of an indirect thermosyphon circulation solar hot water system. Both collectors face south with a fixed tilt angle of 33.3

  4. Summer performance results obtained from simultaneously testing ten solar collectors outdoors

    Science.gov (United States)

    Miller, D. R.

    1977-01-01

    Ten solar collectors were simultaneously tested outdoors. Efficiency data were correlated using a method that separates solar variables (flux, incident angle) from the desired performance parameters (heat loss, absorbtance, transmittance) which are unique to a given collector design. Tests were conducted on both clear and moderately cloudy days. Correlating data in the above manner, a 2-glass, black paint collector exhibited a decrease in efficiency of 5 percentage points relative to the baseline data for an exposure time of 2 years, 4 months. Condensation on the collector glazing was thought to be a contributing factor in this efficiency change.

  5. Standard Test Method for Determining Thermal Performance of Tracking Concentrating Solar Collectors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1987-01-01

    1.1 This test method covers the determination of thermal performance of tracking concentrating solar collectors that heat fluids for use in thermal systems. 1.2 This test method applies to one- or two-axis tracking reflecting concentrating collectors in which the fluid enters the collector through a single inlet and leaves the collector through a single outlet, and to those collectors where a single inlet and outlet can be effectively provided, such as into parallel inlets and outlets of multiple collector modules. 1.3 This test method is intended for those collectors whose design is such that the effects of diffuse irradiance on performance is negligible and whose performance can be characterized in terms of direct irradiance. Note 1—For purposes of clarification, this method shall apply to collectors with a geometric concentration ratio of seven or greater. 1.4 The collector may be tested either as a thermal collection subsystem where the effects of tracking errors have been essentially removed from t...

  6. Experience with building integrated solar collectors; Erfaring med bygningsintegrerte solfangere

    Energy Technology Data Exchange (ETDEWEB)

    Simonsen, Ingeborg; Time, Berit; Andresen, Inger

    2011-07-01

    The main objective of the research 'Zero Emission Buildings' ZEB is to develop products and solutions that provide buildings with zero greenhouse gas emissions associated with the production, operation and disposal. Can we make this happen must the building produce more energy than it needs to compensate for greenhouse gas emissions from the production of materials and the actual construction.To build up knowledge on experience with building integrated solar collectors in Norway, we have in this study made interviews with suppliers and manufacturers of solar collectors and some building owners. Since the focus is on climate shell, we have limited the study to include solar collectors to replace a part of the cladding or roofing. Construction upstairs roofing, outside facade or freestanding rack is not considered as building integrated in this context. The providers we have been in contact with appeals to slightly different parts of the market. This is reflected in the product's development, assembly and approach to the calculation of energy delivery. Overall, providers may offer a range of products suitable for both the professional and skilled carpenter, the interested 'man in the street' . The feedback we have received shows generally good experiences with the product and the installation. Because of the preliminary short operating periods of the investigated plants we have little data on energy supply from these plants. In summary, we can say that the knowledge and the products are available and it is up to use to use them.(Author)

  7. Fuel cell collector plates with improved mass transfer channels

    Science.gov (United States)

    Gurau, Vladimir; Barbir, Frano; Neutzler, Jay K.

    2003-04-22

    A fuel cell collector plate can be provided with one or more various channel constructions for the transport of reactants to the gas diffusion layer and the removal of water therefrom. The outlet channel can be arranged to have a reduced volume compared to the inlet channel, in both interdigitated and discontinuous spiral applications. The land width between an inlet channel and outlet channel can be reduced to improved mass flow rate in regions of deleted reactant concentrations. Additionally or alternatively, the depth of the inlet channel can be reduced in the direction of flow to reduce the diffusion path as the concentration of reactant is reduced.

  8. Nanoparticles Ni electroplating and black paint for solar collector applications

    OpenAIRE

    Nady, J.; Kashyout, A.B.; Ebrahim, Sh.; Soliman, M.B.

    2017-01-01

    A nanoparticles layer of bright nickel base was deposited on copper substrates using electrodeposition technique before spraying the paint. IR reflectance of the paint was found to be around 0.4 without bright nickel layer and the reflectance increased to 0.6 at a Ni layer thickness of 750 nm. The efficiency of the constructed solar collectors using black paint and black paint combined with bright nickel was found to be better than black paint individually. After aging tests under high temper...

  9. Fuzzy Universal Model Approximator for Distributed Solar Collector Field Control

    KAUST Repository

    Elmetennani, Shahrazed

    2014-07-01

    This paper deals with the control of concentrating parabolic solar collectors by forcing the outlet oil temperature to track a set reference. A fuzzy universal approximate model is introduced in order to accurately reproduce the behavior of the system dynamics. The proposed model is a low order state space representation derived from the partial differential equation describing the oil temperature evolution using fuzzy transform theory. The resulting set of ordinary differential equations simplifies the system analysis and the control law design and is suitable for real time control implementation. Simulation results show good performance of the proposed model.

  10. Theoretical Study of the Compound Parabolic Trough Solar Collector

    Directory of Open Access Journals (Sweden)

    Dr. Subhi S. Mahammed

    2012-06-01

    Full Text Available Theoretical design of compound parabolic trough solar collector (CPC without tracking is presented in this work. The thermal efficiency is obtained by using FORTRAN 90 program. The thermal efficiency is between (60-67% at mass flow rate between (0.02-0.03 kg/s at concentration ratio of (3.8 without need to tracking system.The total and diffused radiation is calculated for Tikrit city by using theoretical equations. Good agreement between present work and the previous work.

  11. Lobster eye as a collector for water window microscopy

    Science.gov (United States)

    Pina, L.; Maršíková, V.; Inneman, A.; Nawaz, M. F.; Jančárek, A.; Havlíková, R.

    2017-08-01

    Imaging in EUV, SXR and XR spectral bands of radiation is of increasing interest. Material science, biology and hot plasma are examples of relevant fast developing areas. Applications include spectroscopy, astrophysics, Soft X-ray Ray metrology, Water Window microscopy, radiography and tomography. Especially Water Window imaging has still not fully recognized potential in biology and medicine microscopy applications. Theoretical study and design of Lobster Eye (LE) optics as a collector for water window (WW) microscopy and comparison with a similar size ellipsoidal mirror condensor are presented.

  12. Analysis, simulation, and experimental studies of YAG and CO2 laser-produced plasma for EUV lithography sources

    Science.gov (United States)

    Hassanein, A.; Sizyuk, V.; Harilal, S. S.; Sizyuk, T.

    2010-04-01

    Efficient laser systems are essential for the realization of high volume manufacturing in extreme ultraviolet lithography (EUVL). Solid-state Nd:YAG lasers usually have lower efficiency and source suppliers are alternatively investigating the use of high power CO2 laser systems. However, CO2 laser-produced plasmas (LPP) have specific characteristics and features that should be taken into account when considering them as the light source for EUVL. The analysis of recent experimental and theoretical work showed significant differences in the properties of plasma plumes produced by CO2 and the Nd:YAG lasers including EUV radiation emission, source formation, debris generation, and conversion efficiency. The much higher reflectivity of CO2 laser from liquid, vapor, and plasma of a tin target results in the production of optically thinner plumes with higher velocity and in a better formation of plasma properties (temperature and density values) towards more efficient EUV source. However, the spikes in the temporal profiles of current CO2 laser will additionally affect the properties of the produced plasma. We have developed unique combination of state-of-the-art experimental facilities (CMUXE Laboratory) and advanced computer simulation (HEIGHTS) package for studying and optimizing various lasers, discharge produced plasmas (DPP), and target parameters as well as the optical collection system regarding EUV lithography. In this work, detailed characteristics of plasmas produced by CO2 and Nd:YAG lasers were analyzed and compared both experimentally and theoretically for optimizing EUV from LPP sources. The details of lower overheating of plasma produced by CO2 laser are given with time and explain how to utilize the high reflectivity of such lasers in plasmas produced in different target geometries to significantly enhance the conversion efficiency of EUV radiation.

  13. Genesis Solar Wind Collector Cleaning Assessment: Update on 60336 Sample Case Study

    Science.gov (United States)

    Goreva, Y. S.; Allums, K. K.; Gonzalez, C. P.; Jurewicz, A. J.; Burnett, D. S.; Allton, J. H.; Kuhlman, K. R.; Woolum, D.

    2015-01-01

    To maximize the scientific return of Genesis Solar Wind return mission it is necessary to characterize and remove a crash-derived particle and thin film surface contamination. A small subset of Genesis mission collector fragments are being subjected to extensive study via various techniques. Here we present an update on the sample 60336, a Czochralski silicon (Si-CZ) based wafer from the bulk array (B/C). This sample has undergone multiple cleaning steps (see the table below): UPW spin wash, aggressive chemical cleanings (including aqua regia, hot xylene and RCA1), as well as optical and chemical (EDS, ToF-SIMS) imaging. Contamination appeared on the surface of 60336 after the initial 2007 UPW cleaning. Aqua regia and hot xylene treatment (8/13/2013) did little to remove contaminants. The sample was UPW cleaned for the third time and imaged (9/16/13). The UPW removed the dark stains that were visible on the sample. However, some features, like "the Flounder" (a large, 100 micron feature in Fig. 1b) appeared largely intact, resisting all previous cleaning efforts. These features were likely from mobilized adhesive, derived from the Post-It notes used to stabilize samples for transport from Utah after the hard landing. To remove this contamination, an RCA step 1 organic cleaning (RCA1) was employed. Although we are still uncertain on the nature of the Flounder and why it is resistant to UPW and aqua regia/hot xylene treatment, we have found RCA1 to be suitable for its removal. It is likely that the glue from sticky pads used during collector recovery may have been a source for resistant organic contamination [9]; however [8] shows that UPW reaction with crash-derived organic contamination does not make particle removal more difficult.

  14. Demonstration of domestic hot water with combination of wood stove hot water (winter) and homemade solar collector (summer). Final project report

    Energy Technology Data Exchange (ETDEWEB)

    Nichols, N.S. II

    1981-09-03

    The purpose of this project was to demonstrate that adequate hot water can be provided for a family of four in northeastern Pennsylvania, by using a combination of wood stove hot water in the winter and solar collector hot water during the non-heating months. This demonstration would be to encourage other people in the area to investigate using similar energy-saving systems, by providing an observable operating installation, and by increasing their confidence in using simple alternate-energy sources.

  15. Nanoparticles Ni electroplating and black paint for solar collector applications

    Directory of Open Access Journals (Sweden)

    J. El Nady

    2016-06-01

    Full Text Available A nanoparticles layer of bright nickel base was deposited on copper substrates using electrodeposition technique before spraying the paint. IR reflectance of the paint was found to be around 0.4 without bright nickel layer and the reflectance increased to 0.6 at a Ni layer thickness of 750 nm. The efficiency of the constructed solar collectors using black paint and black paint combined with bright nickel was found to be better than black paint individually. After aging tests under high temperature, Bright nickel improved the stability of the absorber paint. The collector optical gain FR(τα was lowered by 24.7% for the commercial paint and lowered by 19.3% for the commercial paint combined with bright nickel. The overall heat loss FR(UL was increased by 3.3% for the commercial paint and increased by 2.7% for the commercial paint combined with bright nickel after the temperature aging test.

  16. Parabolic Trough Photovoltaic/Thermal Collectors: Design and Simulation Model

    Directory of Open Access Journals (Sweden)

    Laura Vanoli

    2012-10-01

    Full Text Available This paper presents a design procedure and a simulation model of a novel concentrating PVT collector. The layout of the PVT system under investigation was derived from a prototype recently presented in literature and commercially available. The prototype consisted in a parabolic trough concentrator and a linear triangular receiver. In that prototype, the bottom surfaces of the receiver are equipped with mono-crystalline silicon cells whereas the top surface is covered by an absorbing surface. The aperture area of the parabola was covered by a glass in order to improve the thermal efficiency of the system. In the modified version of the collector considered in this paper, two changes are implemented: the cover glass was eliminated and the mono-crystalline silicon cells were replaced by triple-junction cells. In order to analyze PVT performance, a detailed mathematical model was implemented. This model is based on zero-dimensional energy balances. The simulation model calculates the temperatures of the main components of the system and the main energy flows Results showed that the performance of the system is excellent even when the fluid temperature is very high (>100 °C. Conversely, both electrical and thermal efficiencies dramatically decrease when the incident beam radiation decreases.

  17. Rates of Dry Deposition Determined Using Wet/Dry Collectors

    Science.gov (United States)

    Feely, H. W.; Bogen, D. C.; Nagourney, S. J.; Torquato, C. C.

    1985-02-01

    Daily samples of dryfall were collected during the June 1982 Dry Deposition Measurement Intercomparison Study at Champaign, Illinois, using six Aerochem Metrics wet/dry collectors. Upon completion of the field experiment, these samples were analyzed at the Environmental Measurements Laboratory for pH and for their concentrations of major inorganic constituents. Contamination by rain and bird droppings rendered a number of dryfall samples unusuable. When data for these samples were removed, the remaining data displayed acceptable precision for sulfate, calcium, and magnesium. The measured deposition rates varied between 7 and 73 ng/m2/s for sulfate, between 7 and 44 for calcium, and between 0.8 and 8.1 for magnesium. The precision of the data for ammonium, nitrate, and phosphate was poor, so we have not calculated deposition rates for these constituents. The measurements of the atmospheric concentrations of sulfate reported by the Illinois State Water Survey have been used to calculate deposition velocities for particulate sulfate for 18 daily samples, even though the aerosol sampler and the dry bucket of the wet/dry collector may not sample the same size population of particulates. These velocities ranged from 0.1 to 1.2 cm/s, with a median value of 0.4 cm/s and a mean of 0.45±0.31 cm/s.

  18. Investigating effect of different reflective surfaces on solar thermal collector

    Science.gov (United States)

    Chua, Yaw Long; Chin, Kiat Keong; Tay, Tee Tiong

    2017-11-01

    This paper reports on the experiments conducted to investigate the efficiency of different type of reflecting surfaces used on solar thermal collector. Three types of commonly available reflective surfaces coated with silver colour acrylic paint, reflective aluminium foil and blank compact disc are investigated. In this paper, the effect of different reflective surfaces on the water container and parabolic concentrator dish are investigated. In the first experiment, two types of surfaces, coated with silver colour acrylic paint and black colour acrylic paint on an aluminium container are compared. The other factors that might influence the experiment outcome like the material, focal point, and weather condition are kept constant. The experiment results proved that black colour surface is better in absorbing heat reflected by the parabolic dish. The second experiment focused on investigating the effect of different reflective surfaces on the parabolic concentrator dish itself. These surfaces are tested on a parabolic disc of a static solar thermal collector that reflects heat from the sun to a body of water stored in a black colour aluminium container. The temperature of the water is measured at a predetermined interval to measure the efficiency of the reflective surfaces used. It is found that the aluminium reflective surface performed the best compared to the other surfaces.

  19. Cable tensioned membrane solar collector module with variable tension control

    Science.gov (United States)

    Murphy, Lawrence M.

    1985-01-01

    Disclosed is a solar collector comprising a membrane for concentrating sunlight, a plurality of elongated structural members for suspending the membrane member thereon, and a plurality of control members for adjustably tensioning the membrane member, as well as for controlling a focus produced by the membrane members. Each control member is disposed at a different corresponding one of the plurality of structural members. The collector also comprises an elongated flexible tensioning member, which serves to stretch the membrane member and to thereafter hold it in tension, and a plurality of sleeve members, which serve to provide the membrane member with a desired surface contour during tensioning of the membrane member. The tensioning member is coupled to the structural members such that the tensioning member is adjustably tensioned through the structural members. The tensioning member is also coupled to the membrane member through the sleeve members such that the sleeve members uniformly and symmetrically stretch the membrane member upon applying tension to the tensioning member with the control members.

  20. Optimization of Dish Solar Collectors with and without Secondary Concentrators

    Science.gov (United States)

    Jaffe, L. D.

    1982-01-01

    Methods for optimizing parabolic dish solar collectors and the consequent effects of various optical, thermal, mechanical, and cost variables are examined. The most important performance optimization is adjusting the receiver aperture to maximize collector efficiency. Other parameters that can be adjusted to optimize efficiency include focal length, and, if a heat engine is used, the receiver temperature. The efficiency maxima associated with focal length and receiver temperature are relatively broad; it may, accordingly, be desirable to design somewhat away from the maxima. Performance optimization is sensitive to the slope and specularity errors of the concentrator. Other optical and thermal variables affecting optimization are the reflectance and blocking factor of the concentrator, the absorptance and losses of the receiver, and, if a heat engine is used, the shape of the engine efficiency versus temperature curve. Performance may sometimes be improved by use of an additional optical element (a secondary concentrator) or a receiver window if the errors of the primary concentrator are large or the receiver temperature is high.

  1. Theoretical study for solar air pretreatment collector/regenerator

    Energy Technology Data Exchange (ETDEWEB)

    Peng Donggen; Zhang Xiaosong; Yin Yonggao [School of Energy and Environment, Southeast Univ., Nanjing (China)

    2008-07-01

    A new liquid regeneration equipment - solar air pretreatment collector/regenerator for liquid desiccant cooling system is put forward in this paper, which is preferable to solution regeneration in hot and moist climate in South China. The equipment can achieve liquid regeneration in lower temperature. When the solution and the air are in ''match'' state in collector/ regenerator, a match air to salt mass ratio ASMR* is found by theoretical study in which there is the largest theoretical storage capacity SC{sub max}. After two new concepts of the effective solution proportion (EPS) and the effective storage capacity (ESC) are defined, it is found by theoretical calculation that when ESP drops from 100% to 67%, ESC raises lowly, not drops and liquid outlet concentration C{sub str} {sub sol} increases from 40% to 49% in which its increment totals to 90%. All these data explain fully that air pretreatment liquid regeneration equipment enables to improve the performance of liquid desiccant cooling system. (orig.)

  2. Slope Error Measurement Tool for Solar Parabolic Trough Collectors: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Stynes, J. K.; Ihas, B.

    2012-04-01

    The National Renewable Energy Laboratory (NREL) has developed an optical measurement tool for parabolic solar collectors that measures the combined errors due to absorber misalignment and reflector slope error. The combined absorber alignment and reflector slope errors are measured using a digital camera to photograph the reflected image of the absorber in the collector. Previous work using the image of the reflection of the absorber finds the reflector slope errors from the reflection of the absorber and an independent measurement of the absorber location. The accuracy of the reflector slope error measurement is thus dependent on the accuracy of the absorber location measurement. By measuring the combined reflector-absorber errors, the uncertainty in the absorber location measurement is eliminated. The related performance merit, the intercept factor, depends on the combined effects of the absorber alignment and reflector slope errors. Measuring the combined effect provides a simpler measurement and a more accurate input to the intercept factor estimate. The minimal equipment and setup required for this measurement technique make it ideal for field measurements.

  3. Investigation of a novel discharge EUV source for microlithography

    Science.gov (United States)

    Bauer, Bruno S.; Makhin, Volodymyr; Fuelling, Stephan; Lindemuth, Irvin R.

    2006-03-01

    A plasma discharge could be an inexpensive and efficient EUV source for microlithography, if issues of brightness, lifetime, debris, repetition rate, and stability can be resolved. A novel discharge EUV source (international patent pending) is being investigated that may offer an economical solution to these issues. The novel EUV discharge seeks to efficiently assemble a hot, dense, uniform, axially stable plasma with magnetic pressure and inductive current drive, employing resonant theta-pinch-type compression of plasma confined in a magnetic mirror. This resonantly compressed mirror plasma (RCMP) source would be continuously driven by a radio frequency oscillator, to obtain an EUV conversion efficiency greater than that of sources in which the plasma is discarded after each radiation burst. An analytic calculation indicates the novel RCMP source could provide 115 W of 13.45 nm radiation in 3.3 mm2sr etendue to an intermediate focus. Numerical modeling of RCMP dynamics has been performed with MHRDR-EUVL, a magnetohydrodynamic (MHD) numerical simulation with atomic and radiation physics. The numerical simulation demonstrates the efficacy of resonant magneto-acoustic heating. An experiment is being developed to test the new concept.

  4. Evaluation of the flat-plate solar collector system for electric power generation

    Science.gov (United States)

    Athey, R. E.

    1976-01-01

    This evaluation of the flat-plate collector system was designed to determine the number of flat-plate collectors required to generate a given amount of electricity with optimum efficiency. Variable parameters are the temperature of the heat-transport fluid, both to and from the collector field. In the analysis, the efficiency of the flat-plate collectors was coupled to the efficiency of the thermal cycle to calculate optimal overall system efficiencies. Overall system efficiencies for the system are on the order of 3.5 per cent or less. Over two million 4 ft-by-4 ft collectors would be required to produce 100,000 kW(e). Based on the results, it can be shown that the limiting factor in the use of the flat-plate collector system for electric power generation is the efficiency of the collectors. An increase in the overall system efficiency can occur only if the collector efficiency can be increased at higher surface temperatures.

  5. Analysis of the Kirk effect in silicon-based bipolar transistors with a nonuniform collector profile

    NARCIS (Netherlands)

    Hueting, Raymond Josephus Engelbart; van der Toorn, Ramses

    2005-01-01

    In this paper, the Kirk effect has been analyzed for silicon-based bipolar transistors (BJTs) with a nonuniform collector profile. We show that, for any arbitrary collector doping profile, the Kirk effect starts when the electron concentration equals the average doping concentration in the depletion

  6. Growth of juvenile blue mussels (Mytilus edulis) on suspended collectors in the Dutch Wadden Sea

    NARCIS (Netherlands)

    Jacobs, P.; Beauchemin, C.; Riegman, R.

    2014-01-01

    In The Netherlands, fishing for juvenile blue mussels (Mytilus edulis) on wild beds is gradually replaced by harvesting of seeds from suspended collectors. Both the relaxation of fishing as well as the up-scaling of the number of seed collectors are expected to result in an increase in the number of

  7. METAL-POLYMER SOLAR COLLECTORS WITH MULTICHANNEL ABSORBER FOR MULTIFUNCTIONAL MULTIPURPOSE ENERGY SYSTEMS

    Directory of Open Access Journals (Sweden)

    Doroshenko A.

    2012-08-01

    Full Text Available New modification of liquid-metal-polymer solar collector for solar heating and for creation of multifunctional energy systems on its basis, particularly solar refrigeration systems was developed. A comparative study of several modifications of polymer collectors involving data of a set of foreign researchers was made and high efficiency of the new elaboration was proven.

  8. The Experimental Performance of an Unglazed PVT Collector with Two Different Absorber Types

    Directory of Open Access Journals (Sweden)

    Jin-Hee Kim

    2012-01-01

    Full Text Available Photovoltaic-thermal collectors combine photovoltaic modules and solar thermal collectors, forming a single device that produces electricity and heat simultaneously. There are two types of liquid-type PVT collectors, depending on the existence or absence of a glass cover over the PV module. The glass-covered (glazed PVT collector produces relatively more thermal energy but has a lower electrical yield, whereas the uncovered (unglazed PVT collector has a relatively low thermal energy and somewhat higher electrical performance. The thermal and electrical performance of liquid-type PVT collectors is related not only to the collector design, such as whether a glass cover is used, but also to the absorber design, that is, whether the absorber is for the sheet-and-tube type or the fully wetted type. The design of the absorber, as it comes into contact with the PV modules and the liquid tubes, is regarded as important, as it is related to the heat transfer from the PV modules to the liquid in the tubes. In this paper, the experimental performance of two liquid-type PVT collectors, a sheet-and-tube type and a fully wetted type, was analyzed.

  9. Comparative test of two large solar collectors for solar field application

    DEFF Research Database (Denmark)

    Bava, Federico; Furbo, Simon

    2014-01-01

    Two large solar collectors for solar heating plants were tested according to the standard norm EN 12975-2. The two collectors were almost identical, the only difference being a thin FEP (fluorinated ethylene propylene) foil interposed between the absorber and the glass cover in one of them...

  10. Study of Performance of Coaxial Vacuum Tube Solar Collector on Ethanol Distillation Process

    Science.gov (United States)

    Sutomo; Ramelan, A. H.; Mustafa; Tristono, T.

    2017-07-01

    Coaxial vacuum tube solar collectors can generate heat up to 80°C is possibly used for ethanol distillation process that required temperature 79°C only. This study reviews the performance of coaxial collector vacuum tube used for ethanol distillation process. This experimental research was conducted in a closed space using a halogen lamp as a solar radiation simulator. We had done on three different of the radiation values, i.e. 998 W/m2, 878 W/m2 and 782 W/m2. The pressure levels of vacuum tube collector cavity in the research were 1; 0.5; 0.31; 0.179; and 0.043 atmospheres. The Research upgraded the 30% of ethanol to produce the concentration of 77% after distillation. The result shows that the performance of coaxial collector vacuum tube used for ethanol distillation process has the negative correlation to the level of the collector tube cavity pressure. The productivity will increase while the collector tube cavity pressure decreased. Therefore, the collector efficiency has the negative correlation also to the level of collector tube cavity pressure. The best performance achieved when it operated at a pressure of 0.043 atmosphere with radiation intensity 878 W / m2, and the value of efficiency is 57.8%.

  11. Aging and corrosion problems of plane thermal solar collectors: literature and field investigations

    Energy Technology Data Exchange (ETDEWEB)

    Wennerholm, H.; Lagerkvist, K.U.

    1979-01-01

    The literature and field investigation will be the basis of a project concerning the development of standardized methods for the test of solar collectors which are used in heating and cooling systems. The literature and field investigations include the study of the construction of plane thermal solar collectors as well as atmospheric degradation processes on different construction materials.

  12. 30 CFR 18.21 - Machines equipped with powered dust collectors.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Machines equipped with powered dust collectors... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.21 Machines equipped with powered dust collectors. Powered dust...

  13. Preliminary design review package on air flat plate collector for solar heating and cooling system

    Science.gov (United States)

    1977-01-01

    Guidelines to be used in the development and fabrication of a prototype air flat plate collector subsystem containing 320 square feet (10-4 ft x 8 ft panels) of collector area are presented. Topics discussed include: (1) verification plan; (2) thermal analysis; (3) safety hazard analysis; (4) drawing list; (5) special handling, installation and maintenance tools; (6) structural analysis; and (7) selected drawings.

  14. Emotion, desire and reverie in the consumption practices from the recyclable material collectors

    Directory of Open Access Journals (Sweden)

    Josilene Barbosa do Nascimento

    2014-08-01

    imagination. Thus, pointing out how works the self delusion of the collectors, characteristic of modern consumption, as we watch for the excitement and the individual values governing their consumption practices as pointing work. In this sense, the collectors consume to satiate subjectively established wills: it is the emotional consumption.

  15. 22 CFR 91.2 - Furnishing samples to collectors of customs or appraising officers.

    Science.gov (United States)

    2010-04-01

    ... appraising officers. 91.2 Section 91.2 Foreign Relations DEPARTMENT OF STATE LEGAL AND RELATED SERVICES IMPORT CONTROLS § 91.2 Furnishing samples to collectors of customs or appraising officers. Upon the receipt of a request therefor from a collector of customs or appraising officer of the Government of the...

  16. A Computer-Interfaced Drop Counter as an Inexpensive Fraction Collector for Column Chromatography

    Science.gov (United States)

    Nash, Barbara T.

    2008-01-01

    A computer-interfaced drop counter is described that serves as an inexpensive alternative to a fraction collector for column chromatography experiments. Undergraduate biochemistry laboratories frequently do not have the budget to purchase fraction collectors. Protocols that call for the manual measurement of fraction volumes as well as the manual…

  17. A Didactic Experiment and Model of a Flat-Plate Solar Collector

    Science.gov (United States)

    Gallitto, Aurelio Agliolo; Fiordilino, Emilio

    2011-01-01

    We report on an experiment performed with a home-made flat-plate solar collector, carried out together with high-school students. To explain the experimental results, we propose a model that describes the heating process of the solar collector. The model accounts quantitatively for the experimental data. We suggest that solar-energy topics should…

  18. Effect of collector molecular structure on the wettability of gold for froth flotation

    Science.gov (United States)

    Moncayo-Riascos, Ivan; Hoyos, Bibian A.

    2017-10-01

    Molecular dynamics simulations were conducted to evaluate the alteration of the hydrophilic state of gold surfaces caused by the adsorption of collectors with different molecular structures, using the contact angle of water droplets as an evaluation parameter. Four collectors were evaluated: SDS (with twelve hydrogenated carbon atoms), PAX (with five hydrogenated carbon atoms), DTP (with two branched aliphatic chains) and MBT (with an aromatic ring). The contact angle was evaluated for coatings of a monolayer (ML) and for surface densities of 2.89 μmol/m2 for each collector. For a ML, the hydrophobic effect generated by the aromatic ring of the MBT collector is comparable with the effect of the non-polar short chain of the PAX collector. The increase in hydrophobicity for the gold surfaces achieved by collectors with aliphatic chains is because the water-collector interaction energy is significantly higher (repulsive) than the water-gold interactions (attractive). The lowest increase in hydrophobicity was achieved with the MBT collector, since the carbon-water interaction energy of the aromatic ring is stronger than the interaction with the carbon atoms in the aliphatic chains. The calculated contact angles of the water droplets deviated less than 4% with respect to the experimental values.

  19. SIDE-BY-SIDE TESTS OF DIFFERENTLY DESIGNED EVACUATED TUBULAR COLLECTORS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Dragsted, Janne; Furbo, Simon

    2007-01-01

    . and one all-glass ETC with heat pipe from Exoheat AB. The collectors have been investigated side-by-side in an outdoor test facility for a long period. During the measurements, the operating conditions – such as weather conditions, inlet and mean solar collector fluid temperatures have been the same. Thus...

  20. The effect of precipitation collector design on the measured acid content of precipitation

    Science.gov (United States)

    H. A. Weibe

    1976-01-01

    In order to evaluate the effect of different types of collectors on the measured chemical constituents of monthly precipitation collections, an array of fourteen precipitation samplers of five different designs has been in operation at Woodbridge, Ontario since March 1974. The collectors are located in an open field near the city of Toronto in an area of approximately...

  1. Different collector types for sampling deposition of polycyclic aromatic hydrocarbons - Comparison of measurement results and their uncertainty

    NARCIS (Netherlands)

    Gladtke, D.; Bakker, F.; Biaudet, H.; Brennfleck, A.; Coleman, P.; Creutznacher, H.; Egmond, B.F. van; Hafkenscheid, T.; Hahne, F.; Houtzager, M.M.; Leoz-Garziandia, E.; Menichini, E.; Olschewski, A.; Remesch, T.

    2012-01-01

    Different collector types, sample workup procedures and analysis methods to measure the deposition of polycyclic aromatic hydrocarbons (PAH) were tested and compared. Whilst sample workup and analysis methods did not influence the results of PAH deposition measurements, using different collector

  2. Results of thermal performance evaluation of the Owens-Illinois sunpack liquid solar collector at indoor conditions

    Science.gov (United States)

    1979-01-01

    Test procedures and results of the thermal performance of a liquid, evacuated tube, solar collector under simulated conditions are presented. The collector tested was a module used on the early demonstration projects.

  3. Tårs 10000 m2 CSP + Flat Plate Solar Collector Plant - Cost-Performance Optimization of the Design

    DEFF Research Database (Denmark)

    Perers, Bengt; Furbo, Simon; Tian, Zhiyong

    2016-01-01

    A novel solar heating plant with Concentrating Solar Power (CSP) collectors and Flat Plate (FP) collectors has been put into operation in Tårs since July 2015. To investigate economic performance of the plant, a TRNSYS-Genopt model, including a solar collector field and thermal storage tank......, was established. The optimization showed that there was a synergy in combining CSP and FP collectors. Even though the present cost per m² of the CSP collectors is high, the total energy cost is minimized by installing a combination of collectors in such solar heating plant. It was also found that the CSP...... collectors could raise flexibility in the control strategy of the plant. The TRNSYS-Genopt model is based on individually validated component models and collector parameters from experiments. Optimization of the cost performance of the plant has been conducted in this paper. The simulation model remains...

  4. The Influence of Different Absorbed Coatings on Thermal Effect of Prefabricated Solar Collector Panels

    Directory of Open Access Journals (Sweden)

    Wang Qi

    2016-01-01

    Full Text Available Prefabricated solar collector panels is a kind of new permeability structure of collector panels. For this test, we adopt a certain proportion of copper oxide, magnesium oxide and iron oxide to enamel paint as absorbed panel coating and make two kinds of collector panels for different forms of color by dark green coating and black coating. By the methods of comparison, the two kinds of panel collector efficiency and heat loss coefficient UL were tested. The results showed that there was a slight difference between the heat loss coefficient of prefabricated solar collector panels, using the panel with dark green coating’s comprehensive thermal effect is well than the panel with black coating. The beautiful appearance color is more suitable for building requirements.

  5. Models of the heat dynamics of solar collectors for performance testing

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Perers, Bengt

    2011-01-01

    The need for fast and accurate performance testing of solar collectors is increasing. This paper describes a new technique for performance testing which is based on non-linear continuous time models of the heat dynamics of the collector. It is shown that all important performance parameters can...... be accurately estimated with measurements from a single day. The estimated parameters are compared with results from standardized test methods (Fischer et al., 2004). Modelling the dynamics of the collector is carried out using stochastic differential equations, which is a well proven efficient method to obtain......) and modelling of the heat dynamics of buildings (Madsen and Holst, 1995). Measurements obtained at a test site in Denmark during the spring 2010 are used for the modelling. The tested collector is a single glazed large area flat plate collector with selective absorber and Teflon anti convection layer. The test...

  6. Method Of Making Solar Collectors By In-Situ Encapsulation Of Solar Cells

    Science.gov (United States)

    Carrie, Peter J.; Chen, Kingsley D. D.

    2000-10-24

    A method of making solar collectors by encapsulating photovoltaic cells within a base of an elongated solar collector wherein heat and pressure are applied to the cells in-situ, after an encapsulating material has been applied. A tool is fashioned having a bladder expandable under gas pressure, filling a region of the collector where the cells are mounted. At the same time, negative pressure is applied outside of the bladder, enhancing its expansion. The bladder presses against a platen which contacts the encapsulated cells, causing outgassing of the encapsulant, while heat cures the encapsulant. After curing, the bladder is deflated and the tool may be removed from the collector and base and reflective panels put into place, if not already there, thereby allowing the solar collector to be ready for use.

  7. Modeling Heat Flow In a Calorimeter Equipped With a Textured Solar Collector

    Science.gov (United States)

    Jaworske, Donald A.; Allen, Bradley J.

    2001-01-01

    Heat engines are being considered for generating electric power for minisatellite applications, particularly for those missions in high radiation threat orbits. To achieve this objective, solar energy must be collected and transported to the hot side of the heat engine. A solar collector is needed having the combined properties of high solar absorptance, low infrared emittance, and high thermal conductivity. To test candidate solar collector concepts, a simple calorimeter was designed, manufactured, and installed in a bench top vacuum chamber to measure heat flow. In addition, a finite element analysis model of the collector/calorimeter combination was made to model this heat flow. The model was tuned based on observations from the as-manufactured collector/calorimeter combination. In addition, the model was exercised to examine other collector concepts, properties, and scale up issues.

  8. Attaching solar collectors to a structural framework utilizing a flexible clip

    Science.gov (United States)

    Kruse, John S

    2014-03-25

    Methods and apparatuses described herein provide for the attachment of solar collectors to a structural framework in a solar array assembly. A flexible clip is attached to either end of each solar collector and utilized to attach the solar collector to the structural framework. The solar collectors are positioned to allow a member of the framework to engage a pair of flexible clips attached to adjacent solar collectors during assembly of the solar array. Each flexible clip may have multiple frame-engaging portions, each with a flange on one end to cause the flexible clip to deflect inward when engaged by the framework member during assembly and to guide each of the frame-engaging portions into contact with a surface of the framework member for attachment.

  9. Influence of stratification grade in the accumulator tank over la efficiency of solar thermal plate collector facilities; Influencia del grado de estratificacion en el tanque acumulador sobre la eficiencia de las instalaciones fototermicas de colectores planos

    Energy Technology Data Exchange (ETDEWEB)

    Silio, D. S.; Renedo, J. C. E.; Castanera, V. H.

    2004-07-01

    This paper shows a dynamic simulation of a domestic solar thermal installation. This installation produces sanitary hot water and includes different thermal stratification levels in the storage tank The installation consists in a solar flat collector, a tank of water, a source of auxiliary energy, and a device for blending water. The efficiency for each simulation is analyzed and compared. (Author)

  10. Experimental Investigation of a Solar Greenhouse Heating System Equipped with a Parabolic Trough Solar Concentrator and a Double-Purpose Flat Plate Solar Collector

    Directory of Open Access Journals (Sweden)

    M Jafari

    2017-10-01

    Full Text Available Introduction Greenhouses provide a suitable environment in which all the parameters required for growing the plants can be controlled throughout the year. Greenhouse heating is one of the most important issues in productivity of a greenhouse. In many countries, heating costs in the greenhouses are very high, having almost 60-80% of the total production costs. In recent years, several studies have attempted to reduce the heating costs of the greenhouses by applying more energy efficient equipment and using the renewable energy sources as alternatives or supplementary to the fossil fuels. In the present study a novel solar greenhouse heating system equipped with a parabolic trough solar concentrator (PTC and a flat-plate solar collector has been developed. Therefore, the aim of this paper is to investigate the performance of the proposed heating system at different working conditions. Materials and Methods The presented solar greenhouse heating system was comprised of a parabolic trough solar concentrator (PTC, a heat storage tank, a pump and a flat plate solar collector. The PTC was constructed from a polished stainless steel sheet (as the reflector and a vacuum tube receiver. The PTC was connected to the tank by using insulated tubes and a water pump was utilized to circulate the working fluid trough the PTC and the heat exchanger installed between walls of the tank. The uncovered solar collector was located inside the greenhouse. During the sunshine time, a fraction of the total solar radiation received inside the greenhouse is absorbed by the solar collector. This rises the temperature of the working fluid inside the collector which led to density reduction and natural flow of the fluid. In other words, the collector works as a natural flow flat plate solar collector during the sunshine time. At night, when the greenhouse temperature is lower than tank temperature, the fluid flows in a reverse direction through the solar collector and the

  11. Interference filters for colored glazed thermal solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, A.; Roecker, C.; Scartezzini, J.-L. [Swiss Federal Institute of Technology EPFL, Laboratoire d' Energie Solaire et de Physique du Batiment LESO-PB, Lausanne (Switzerland); Boudaden, J.; Videnovic, I. R.; Ho, R. S-C.; Oelhafen, P. [Institut fuer Physik der Universitaet Basel, Basel (Switzerland)

    2003-07-01

    Glazed thermal solar collectors, typically equipped with black, optical selective absorber sheets, exhibit good energy conversion efficiency. However, the black color, and sometimes the visibility of tubes and corrugations of the metal sheets, limit the architectural integration into buildings. In order to overcome this drawback, interference filters are considered as a promising approach. Multilayered thin film stacks deposited on the cover glass can produce a colored reflection hiding the black absorber without a great loss of energy. These interference filters are designed and optimized by numerical simulation. Such coatings can be deposited by vacuum processes (e.g. magnetron sputtering) or via the SolGel method. Optical measurements, such as spectrophotometry or ellipsometry, are used to determine film thicknesses and optical constants of individual layers, and to measure color coordinates and solar transmission for the multilayer stacks. (authors)

  12. Method of forming oxide coatings. [for solar collector heating panels

    Science.gov (United States)

    Mcdonald, G. E. (Inventor)

    1983-01-01

    This invention is concerned with an improved plating process for covering a substrate with a black metal oxide film. The invention is particularly directed to making a heating panel for a solar collector. A compound is electrodeposited from an aqueous solution containing cobalt metal salts onto a metal substrate. This compound is converted during plating into a black, highly absorbing oxide coating which contains hydrated oxides. This is achieved by the inclusion of an oxidizing agent in the plating bath. The inclusion of an oxidizing agent in the plating bath is contrary to standard electroplating practice. The hydrated oxides are converted to oxides by treatment in a hot bath, such as boiling water. An oxidizing agent may be added to the hot liquid treating bath.

  13. Focusing solar collector and method for manufacturing same

    Science.gov (United States)

    Murphy, Lawrence M.

    1984-01-01

    Disclosed is a solar collector comprising an annular-shaped frame and a composite membrane member for concentrating and focusing sun radiation. The composite membrane member is supported and tensioned by the frame and consists of first and second differentially pretensioned sheet members which are integrally bonded to one another. The frame and one of the two sheet members are adapted to allow tensions in both of the sheets to be adjusted. Subsequent to bonding and upon adjusting a tension in one of the two sheet members, both of the two bonded sheet members react with one another so as to cause the composite membrane member to have a contoured configuration, which enables the membrane member to be focusable. Additionally, adjusting the tension in one of the two sheet members provides a reciprocal adjustment in a focus provided by the membrane member.

  14. Introducing CFD in the optical simulation of linear Fresnel collectors

    Science.gov (United States)

    Moghimi, M. A.; Rungasamy, A.; Craig, K. J.; Meyer, J. P.

    2016-05-01

    This paper seeks to determine whether the Finite Volume method within a commercially available Computational Fluid Dynamics (CFD) solver (ANSYS Fluent) can model radiation with comparable accuracy to a Monte Carlo ray-tracing software package (SolTrace). A detailed investigation was performed into modeling techniques that can be used to significantly reduce the optical errors traditionally associated with CFD modeling of radiation false scattering and ray effect using a simple optical test case. The strategies formulated in the first part of this paper were used to model a variety of Linear Fresnel Collector Concentrating Solar Power Plants. This paper shows that commercial CFD packages yield accurate results for line focusing concentrating solar applications and simple geometries, validating its use in an integrated environment where both optical and thermal performance of these plants can be simulated and optimized.

  15. Thermomechanical Assessment of the Collector for the Hollow Electron Lens

    CERN Document Server

    Anderson, George Bowers

    2017-01-01

    The hollow electron lens (HEL) is a system proposed for the High Luminosity upgrade of the Large Hadron Collider LHC (HL-LHC) [1]. Being considered for installation at LHC point 4, the HEL improves halo control and collimation of proton beams in the collider [2]. This is achieved by creating a hollow tube of electrons using an electron gun. This axisymmetric electron cloud travels around the proton beam for a few meters, overlapping with the proton beam halo, until the electron cloud is dissipated in a collector, which is the focus of this project. A 3D image of the HEL system is found in Figure 1 and a further technical description of such electron lenses is available in [3].

  16. Indoor test for the thermal performance evaluation of the DEC 8A large manifold sunmaster evacuated tube (liquid) solar collector

    Science.gov (United States)

    1981-01-01

    The Sunmaster DEC 8A Large Manifold solar collector using simulated conditions was evaluated. The collector provided 17.17 square feet of gross collector area. Test conditions, test requirements, an analysis of results, and tables of test data are reported.

  17. Experimental System of Solar Adsorption Refrigeration with Concentrated Collector.

    Science.gov (United States)

    Yuan, Z X; Li, Y X; Du, C X

    2017-10-18

    To improve the performance of solar adsorption refrigeration, an experimental system with a solar concentration collector was set up and investigated. The main components of the system were the adsorbent bed, the condenser, the evaporator, the cooling sub-system, and the solar collector. In the first step of the experiment, the vapor-saturated bed was heated by the solar radiation under closed conditions, which caused the bed temperature and pressure to increase. When the bed pressure became high enough, the bed was switched to connect to the condenser, thus water vapor flowed continually from the bed to the condenser to be liquefied. Next, the bed needed to cool down after the desorption. In the solar-shielded condition, achieved by aluminum foil, the circulating water loop was opened to the bed. With the water continually circulating in the bed, the stored heat in the bed was took out and the bed pressure decreased accordingly. When the bed pressure dropped below the saturation pressure at the evaporation temperature, the valve to the evaporator was opened. A mass of water vapor rushed into the bed and was adsorbed by the zeolite material. With the massive vaporization of the water in the evaporator, the refrigeration effect was generated finally. The experimental result has revealed that both the COP (coefficient of the performance of the system) and the SCP (specific cooling power of the system) of the SAPO-34 zeolite was greater than that of the ZSM-5 zeolite, no matter whether the adsorption time was longer or shorter. The system of the SAPO-34 zeolite generated a maximum COP of 0.169.

  18. Application of solar flat plate collector in automobile industry

    Energy Technology Data Exchange (ETDEWEB)

    Wawge, P. [Peenya Alloys Pvt. Ltd., Parvati, Pune (India)

    2004-07-01

    In any industry, heating, cooling and compressed air the costliest part, which affects the production cost of any product. There are three types of indirect heat requirement or the requirement of heat can be divided in the three main categories. (1) low temp. 40 - 60 Deg. (2) Medium temp. 80 - 150 deg. (3) High Temp applications - above 150. Solar Flat Collectors have been proven for the use of solar energy for medium temp. application in hotels, boiler feed water preheating, dairy for pasteurization and some other indirect heating applications. There is another neglected area of application of Solar Flat Plate collector is heat treatment for powder coating plants where heat requirement is bet 50 Deg C - 70 Deg C. In any automobile industry the aesthetic or look of the vehicle place a very important role as far as the sale is concern (after the mechanical performance). The aesthetic means the body and colour of the vehicle. To get a long lasting good quality color, the powder coating procedure plays a major role. Before powder coating there is requirement of different chemical treatment for the removal of rust, grease and other cleaning of the specific sheet metal body parts. The time duration and chemical composition is depends on the selection of body material. A proven method of a chemical treatment is seven / eight tank process. The common system of heating chemicals is by way of electrical heaters, by diesel or other fuel fired boilers. This increases the cost of heat treatment process due the high cost of electricity (for industries rate of electricity is 1.5 to 2 times than the domestic rate) or oils. This can be replaced by Solar water heating system which can efficiently generate the temp of liquid upto 85 Deg C. (orig.)

  19. Flat plate solar collector for water pre-heating using concentrated solar power (CSP)

    Science.gov (United States)

    Peris, Leonard Sunny; Shekh, Md. Al Amin; Sarker, Imran

    2017-12-01

    Numerous attempt and experimental conduction on different methods to harness energy from renewable sources are being conducted. This study is a contribution to the purpose of harnessing solar energy as a renewable source by using flat plate solar collector medium to preheat water. Basic theory of solar radiation and heat convection in water (working fluid) has been combined with heat conduction process by using copper tubes and aluminum absorber plate in a closed conduit, covered with a glazed through glass medium. By this experimental conduction, a temperature elevation of 35°C in 10 minutes duration which is of 61.58% efficiency range (maximum) has been achieved. The obtained data and experimental findings are validated with the theoretical formulation and an experimental demonstration model. A cost effective and simple form of heat energy extraction method for space heating/power generation has been thoroughly discussed with possible industrial implementation possibilities. Under-developed and developing countries can take this work as an illustration for renewable energy utilization for sustainable energy prospect. Also a full structure based data to derive concentrated solar energy in any geographical location of Bangladesh has been outlined in this study. These research findings can contribute to a large extent for setting up any solar based power plant in Bangladesh irrespective of its installation type.

  20. Performance Evaluation of a Nanofluid-Based Direct Absorption Solar Collector with Parabolic Trough Concentrator.

    Science.gov (United States)

    Xu, Guoying; Chen, Wei; Deng, Shiming; Zhang, Xiaosong; Zhao, Sainan

    2015-12-04

    Application of solar collectors for hot water supply, space heating, and cooling plays a significant role in reducing building energy consumption. For conventional solar collectors, solar radiation is absorbed by spectral selective coating on the collectors' tube/plate wall. The poor durability of the coating can lead to an increased manufacturing cost and unreliability for a solar collector operated at a higher temperature. Therefore, a novel nanofluid-based direct absorption solar collector (NDASC) employing uncoated collector tubes has been proposed, and its operating characteristics for medium-temperature solar collection were theoretically and experimentally studied in this paper. CuO/oil nanofluid was prepared and used as working fluid of the NDASC. The heat-transfer mechanism of the NDASC with parabolic trough concentrator was theoretically evaluated and compared with a conventional indirect absorption solar collector (IASC). The theoretical analysis results suggested that the fluid's temperature distribution in the NDASC was much more uniform than that in the IASC, and an enhanced collection efficiency could be achieved for the NDASC operated within a preferred working temperature range. To demonstrate the feasibility of the proposed NDASC, experimental performances of an NDASC and an IASC with the same parabolic trough concentrator were furthermore evaluated and comparatively discussed.

  1. Physical effect of a variable magnetic field on the heat transfer of a nanofluid-based concentrating parabolic solar collector

    Science.gov (United States)

    Tahari, M.; Ghorbanian, A.; Hatami, M.; Jing, D.

    2017-12-01

    In this paper, the physical effect of a variable magnetic field on a nanofluid-based concentrating parabolic solar collector (NCPSC) is demonstrated. A section of reservoir is modeled as a semi-circular cavity under the solar radiation with the magnetic source located in the center or out of the cavity and the governing equations were solved by the FlexPDE numerical software. The effect of four physical parameters, i.e., Hartmann Number (Ha), nanoparticles volume fraction ( φ, magnetic field strength ( γ and magnetic source location ( b, on the Nusselt number is discussed. To find the interaction of these parameters and its effect on the heat transfer, a central composite design (CCD) is used and analysis is performed on the 25 experiments proposed by CCD. Analysis of variance (ANOVA) of the results reveals that increasing the Hartmann number decreases the Nusselt number due to the Lorentz force resulting from the presence of stronger magnetic field.

  2. Object-oriented simulation model of a parabolic trough solar collector: Static and dynamic validation

    Science.gov (United States)

    Ubieta, Eduardo; Hoyo, Itzal del; Valenzuela, Loreto; Lopez-Martín, Rafael; Peña, Víctor de la; López, Susana

    2017-06-01

    A simulation model of a parabolic-trough solar collector developed in Modelica® language is calibrated and validated. The calibration is performed in order to approximate the behavior of the solar collector model to a real one due to the uncertainty in some of the system parameters, i.e. measured data is used during the calibration process. Afterwards, the validation of this calibrated model is done. During the validation, the results obtained from the model are compared to the ones obtained during real operation in a collector from the Plataforma Solar de Almeria (PSA).

  3. Stationary concentrating reflector cum tracking absorber solar energy collector: optical design characteristics.

    Science.gov (United States)

    Steward, W G; Kreith, F

    1975-07-01

    This article presents an analysis of the optical design characteristics of a stationary reflecting/tracking absorber solar energy collector. This type of collector consists of a segment of a spherical mirror placed in a stationary position facing the sun, but having a linear absorber that can track the image of the sun by a simple pivoting motion about the center of curvature of the reflector. The optical characteristics of this system and the axial variation of its concentration ratio are developed to provide information for the engineering design and sizing of this type of solar energy collector system.

  4. Thermal-hydraulics of PGV-4 water volume during damage of the feedwater collector nozzles

    Energy Technology Data Exchange (ETDEWEB)

    Logvinov, S.A.; Titov, V.F. [OKB Gidropress (Russian Federation); Notaros, U.; Lenkei, I. [NPP Paks (Hungary)

    1995-12-31

    A number of VVER-440 plants has experienced the distributing nozzles of feedwater collector being damaged due to corrosion-erosion wearing. Such phenomenon could result in feedwater redistribution within the SG inventory with undesirable consequences. The collector with damaged nozzles has to be replaced but a certain time is needed for the preparatory works. The main objective of the investigation conducted is to assess if the safe operation of SG is possible before collector replacement. It was shown that the nozzle damage as observed did not result in the dangerous disturbances of thermobydraulics as compared with the conditions existing at the initial period of operation. (orig.).

  5. Recycled Material Collector: Citizenship and the Social Right to Special Foresight

    Directory of Open Access Journals (Sweden)

    Ana Luiza Felix Severo

    2016-10-01

    Full Text Available The object of this study is to analyze the elements that the recyclable material collector has to belong to particular social class insured. Use shall be bibliographical research with qualitative order to discuss the possibility of granting the benefit under consideration by the social security. Justified by the importance of the collector exercise profitable activity for the recycling industry and promote sound environmental quality. Thus, what is the legal relationship of recyclables collector with special social security? It can be assumed that no such benefits can generate disincentive to exercise this activity, therefore, decline in balanced environment.

  6. Recent Optical and SEM Characterization of Genesis Solar Wind Concentrator Diamond on Silicon Collector

    Science.gov (United States)

    Allton, Judith H.; Rodriquez, M. C.; Burkett, P. J.; Ross, D. K.; Gonzalez, C. P.; McNamara, K. M.

    2013-01-01

    One of the 4 Genesis solar wind concentrator collectors was a silicon substrate coated with diamond-like carbon (DLC) in which to capture solar wind. This material was designed for analysis of solar nitrogen and noble gases [1, 2]. This particular collector fractured during landing, but about 80% of the surface was recovered, including a large piece which was subdivided in 2012 [3, 4, 5]. The optical and SEM imaging and analysis described below supports the subdivision and allocation of the diamond-on-silicon (DOS) concentrator collector.

  7. Standard Practice for Generating All-Day Thermal Performance Data for Solar Collectors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1987-01-01

    1.1 This practice covers a means of generating all-day thermal performance data for flat-plate collectors, concentrating collectors, and tracking collectors. 1.2 The values stated in SI units are to be regarded as the standard. The values given in the parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Solar collector parameter identification from unsteady data by a discrete-gradient optimization algorithm

    Science.gov (United States)

    Hotchkiss, G. B.; Burmeister, L. C.; Bishop, K. A.

    1980-01-01

    A discrete-gradient optimization algorithm is used to identify the parameters in a one-node and a two-node capacitance model of a flat-plate collector. Collector parameters are first obtained by a linear-least-squares fit to steady state data. These parameters, together with the collector heat capacitances, are then determined from unsteady data by use of the discrete-gradient optimization algorithm with less than 10 percent deviation from the steady state determination. All data were obtained in the indoor solar simulator at the NASA Lewis Research Center.

  9. Mathematical modeling of photovoltaic thermal PV/T system with v-groove collector

    Science.gov (United States)

    Zohri, M.; Fudholi, A.; Ruslan, M. H.; Sopian, K.

    2017-07-01

    The use of v-groove in solar collector has a higher thermal efficiency in references. Dropping the working heat of photovoltaic panel was able to raise the electrical efficiency performance. Electrical and thermal efficiency were produced by photovoltaic thermal (PV/T) system concurrently. Mathematical modeling based on steady-state thermal analysis of PV/T system with v-groove was conducted. With matrix inversion method, the energy balance equations are explained by means of the investigative method. The comparison results show that in the PV/T system with the V-groove collector is higher temperature, thermal and electrical efficiency than other collectors.

  10. Effects of flat collectors on soil vegetation and microbes; Auswirkungen von Flachkollektoren auf Bodenvegetation und Kleinlebewesen

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Heinrich; Zottl, Andreas [Austrian Institute of Technology, Wien (Austria). Dept. Energy

    2010-07-01

    Ground coupled heat pumps use the environmental heat of the subsoil via geothermic collectors. In a survey comprising eight selected lower Austrian single-family houses, the influence of geothermic collectors on technical and horticultural factors was investigated. A slight delay in the vegetation period as well as a complete thermal regeneration of the subsoil during the summer months was assessed. Ideally, the design of the landscape coincides with the planning of the geothermal collectors, as the future use and the optimal planting of vegetation can be considered then. (orig.)

  11. Satellite Collectors of Solar Energy for Earth and Colonized Planet Habitats

    Science.gov (United States)

    Kusiolek, Richard

    Summary An array of 55,000 40-foot antennas can generate from the rays of the Sun enough electrical power to replace 50 The economic potential is huge. There are new industries that will only grow and there are different ways to collect solar energy, including wind power. The energy sources we rely on for the most part are finite - fossil fuels, coal, oil and natural gas are all limited in supply. The cost will only continue to rise as demand increases. The time of global economic crossover between the EU, Asia Pacific and North America is coming within less than five years. The biggest opportunity for solar energy entrepreneurs would seem to be in municipal contracting where 1500 40-foot stacking antennas can be hooked into a grid to power an entire city. The antenna can generate 45 kilowatts of energy, enough to satisfy the electrical needs 7x24 of ten to twenty homes. It is possible to design and build 35-by-80-foot pedestals that track the sun from morning until night to provide full efficiency. A normal solar cell looks in the sky for only four or five hours of direct sunlight. Fabrication of these pedestals would sell for USD 50, 000-70,000 each. The solar heat collected by the antennas can be bounced into a Stirling engine, creating electricity at a focal point. Water can be heated by running through that focal point. In addition, salt water passing through the focal point can be desalinated, and since the antenna can generate up to 2,000 degrees of heat at the focal point. The salt water passing through the focal point turns to steam, which separates the salt and allows the steam to be turned into fresh drinking water. Collector energy can be retained in betavoltaics which uses semiconductors to capture energy from radioactive materials and turn it into usable electricity for automobiles. In a new battery, the silicon wafers in the battery are etched with a network of deep pores. These pores vastly increase the exposure surface area of the silicon, allowing

  12. Mathematical model for thermal solar collectors by using magnetohydrodynamic Maxwell nanofluid with slip conditions, thermal radiation and variable thermal conductivity

    Science.gov (United States)

    Mahmood, Asif; Aziz, Asim; Jamshed, Wasim; Hussain, Sajid

    Solar energy is the cleanest, renewable and most abundant source of energy available on earth. The main use of solar energy is to heat and cool buildings, heat water and to generate electricity. There are two types of solar energy collection system, the photovoltaic systems and the solar thermal collectors. The efficiency of any solar thermal system depend on the thermophysical properties of the operating fluids and the geometry/length of the system in which fluid is flowing. In the present research a simplified mathematical model for the solar thermal collectors is considered in the form of non-uniform unsteady stretching surface. The flow is induced by a non-uniform stretching of the porous sheet and the uniform magnetic field is applied in the transverse direction to the flow. The non-Newtonian Maxwell fluid model is utilized for the working fluid along with slip boundary conditions. Moreover the high temperature effect of thermal radiation and temperature dependent thermal conductivity are also included in the present model. The mathematical formulation is carried out through a boundary layer approach and the numerical computations are carried out for cu-water and TiO2 -water nanofluids. Results are presented for the velocity and temperature profiles as well as the skin friction coefficient and Nusselt number and the discussion is concluded on the effect of various governing parameters on the motion, temperature variation, velocity gradient and the rate of heat transfer at the boundary.

  13. Laser produced plasma for efficient extreme ultraviolet light sources

    Energy Technology Data Exchange (ETDEWEB)

    Donnelly, Tony; Cummins, Thomas; O' Gorman, Colm; Li Bowen; Harte, Colm S.; O' Reilly, Fergal; Sokell, Emma; Dunne, Padraig; O' Sullivan, Gerry [School of Physics, University College Dublin, Belfield, Dublin 4 (Ireland)

    2012-05-25

    Extreme ultraviolet emission from laser produced plasma and their relevance to EUV source development is discussed. The current state of the field for Sn LPP sources operating at 13.5 nm is described and initial results are given for EUV emission from CO{sub 2} laser irradiation of a bulk Sn target. A maximum conversion efficiency of 1.7% has been measured and the influence of the CO{sub 2} laser temporal profile on the CE is discussed. A double pulse irradiation scheme is shown to increase CE up to a maximum value of 2.1% for an optimum prepulse - pulse delay of 150 ns. The emergence of a new EUVL source wavelength at 6.7 nm based on Gd and Tb LPPs has been outlined. An initial experiment investigating picosecond laser irradiation as a means to produce strong 6.7 nm emission from a Gd{sub 2}O{sub 3} target has been performed and verified.

  14. Electrolytic/fuel cell bundles and systems including a current collector in communication with an electrode thereof

    Science.gov (United States)

    Hawkes, Grant L.; Herring, James S.; Stoots, Carl M.; O& #x27; Brien, James E.

    2013-03-05

    Electrolytic/fuel cell bundles and systems including such bundles include an electrically conductive current collector in communication with an anode or a cathode of each of a plurality of cells. A cross-sectional area of the current collector may vary in a direction generally parallel to a general direction of current flow through the current collector. The current collector may include a porous monolithic structure. At least one cell of the plurality of cells may include a current collector that surrounds an outer electrode of the cell and has at least six substantially planar exterior surfaces. The planar surfaces may extend along a length of the cell, and may abut against a substantially planar surface of a current collector of an adjacent cell. Methods for generating electricity and for performing electrolysis include flowing current through a conductive current collector having a varying cross-sectional area.

  15. Comparing solar collectors - where the wheat separates from the chaff; Kollektorvergleiche. Wo sich Spreu und Weizen trennen

    Energy Technology Data Exchange (ETDEWEB)

    Abrecht, S.; Griesshaber, W.; Kettner, C.; Meissner, R. [Paradigma GmbH, Karlsbad (Germany)

    2008-12-15

    Solar plants are an important option among climate-friendly energy technologies. However, a closer look at collector technologies available on the market reveals dramatic differences. At high operating temperatures the performance of solar collectors with vacuum insulation stands out clearly against collectors with conventional insulation. Under average or above-average solar radiation conditions with temperature differences relative to ambient levels of 25 K and more not even the best flat-panel collectors can compete technically with tube collectors. The following article shows that only high-performance vacuum tube collectors can cover the requirements of applications involving large-scale process heat. This should have consequences for the allocation of state funds to different collector technologies.

  16. Development and investigation of solar collectors for conversion of solar radiation into heat and/or electricity

    Directory of Open Access Journals (Sweden)

    Stefanović Velimir P.

    2006-01-01

    Full Text Available This article describes work on two projects of the National Energy Efficiency Program NEEP 709300036 and NPEE 271003 titled "The model of solar collector for middle temperature conversion of solar radiation in heat" and "Development and investigation on hybrid solar collector for heat and electricity generation", respectively. This first project deals with solar collector that transfers solar radiation in heat in area of middle temperature conversion (at temperatures above 100 ºC. During entire year it can realize significant saving of electric energy used for preparation of warm water and in central and district heating. During work on the second project, two hybrid solar collectors, their installation, mathematical model, software, and experimental set-up were designed and realized. The first collector had the photovoltaic panel located above the absorber and the second collector had the panel located on the absorber. For both collectors, the results show that efficiency of fossil fuel replacement is 85%. .

  17. Experimental Investigation of a Direct Methanol Fuel Cell with Hilbert Fractal Current Collectors

    Directory of Open Access Journals (Sweden)

    Jing-Yi Chang

    2014-01-01

    Full Text Available The Hilbert curve is a continuous type of fractal space-filling curve. This fractal curve visits every point in a square grid with a size of 2×2, 4×4, or any other power of two. This paper presents Hilbert fractal curve application to direct methanol fuel cell (DMFC current collectors. The current collectors are carved following first, second, and third order Hilbert fractal curves. These curves give the current collectors different free open ratios and opening perimeters. We conducted an experimental investigation into DMFC performance as a function of the free open ratio and opening perimeter on the bipolar plates. Nyquist plots of the bipolar plates are made and compared using electrochemical impedance spectroscopy (EIS experiments to understand the phenomena in depth. The results obtained in this paper could be a good reference for future current collector design.

  18. Comparative performance of twenty-three types of flat plate solar energy collectors

    Science.gov (United States)

    Simon, F. F.

    1975-01-01

    Report compares efficiencies of 23 solar collectors for four different purposes: operating a Rankine-cycle engine, heating or absorption air conditioning, heating hot water, and heating a swimming pool.

  19. Experimental Validation and Model Verification for a Novel Geometry ICPC Solar Collector

    DEFF Research Database (Denmark)

    Perers, Bengt; Duff, William S.; Daosukho, Jirachote

    A novel geometry ICPC solar collector was developed at the University of Chicago and Colorado State University. A ray tracing model has been designed to investigate the optical performance of both the horizontal and vertical fin versions of this collector. Solar radiation is modeled as discrete...... to the desired incident angle of the sun’s rays, performance of the novel ICPC solar collector at various specified angles along the transverse and longitudinal evacuated tube directions were experimentally determined. To validate the ray tracing model, transverse and longitudinal performance predictions...... at the corresponding specified incident angles are compared to the Sandia results. A 100 m2 336 Novel ICPC evacuated tube solar collector array has been in continuous operation at a demonstration project in Sacramento California since 1998. Data from the initial operation of the array are used to further validate...

  20. Experiments and simulations on a thermosyphon solar collector with integrated storage

    Science.gov (United States)

    Toninelli, P.; Mariani, A.; Del, D., Col

    2015-11-01

    This paper deals with the thermal behaviour of a new type of flat solar collector that integrates the fluid storage tank. Often the main limitation of the solar thermosyphon installations is the prohibition to adopt external storage tanks due to their impact, especially for historical centres of particular architectural significance. To avoid this issue, a new system, that includes the collector and the storage, has been developed. This new apparatus works as a thermosyphon: it is possible to take advantage of the natural convection to avoid using a pump. Experimental tests have been conducted in such a collector with and without the absorbing plate. Furthermore, CFD simulations are reported to analyze in detail the dynamic thermal performance of the innovative solar collector and a good-agreement with the experimental tests has been found. Finally, both in numerical simulations and in experimental data the thermosyphon effect has been verified, obtaining the desired water temperature for domestic applications.

  1. Study of thermohydraulic characteristics of upgraded feedwater collector in PGV-440 steam generator

    Energy Technology Data Exchange (ETDEWEB)

    Tarankov, G.A.; Trunov, N.B.; Titov, V.F. [OKB Gidropress (Russian Federation); Urbansky, V.V. [Rovno NPP (Ukraine); Lenkei, I.; Notarosh, M. [Paks NPP (Hungary)

    1995-12-31

    Reconstruction of feedwater distribution collector was performed at unit 1 of Rowno NPP. Main results of measurements of temperatures in water volume, reparation characteristics and impurities distribution are presented. Analysis of tests results and design criteria is given. (orig.).

  2. A diagram for defined solar radiation absorbed per unit area of flat plate solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Tekin, Y.; Altuntop, N. [Erciyes University, Dept. of Mechanical Engineering (Turkey); Cengel, Y.A. [Nevada Reno University, Dept. of Mechanical Engineering, NV (United States); Cengel, Y.A. [Nevada University, Dept. Mechanical Engineering, Reno, NV (United States)

    2000-07-01

    In Erciyes University, the Solar House (28.75 m{sup 2}) is heated from the floor by using flat plate liquid solar collectors. Required solar radiation for heating and heat losses are calculated. In this work, the required calculations for Erciyes Solar House were generalized and required calculation were done to evaluate absorbed solar radiation per unit surface of the flat plate liquid collector. At the end, three generalized diagrams for nine different months are obtained using obtained numerical values. The goal of preparing diagrams is to determine absorbed solar radiation per unit surface area of flat plate liquid collector at any instant at any latitude, In this work, the diagram is explained by means of sample calculations for November. This diagram was prepared to find out absorbed solar radiation per unit area of black surface collector by means obtained equations. With this diagram, all instant solar radiation can be evaluated in 19 steps. (authors)

  3. Buoyancy effects on thermal behavior of a flat-plate solar collector

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon

    2008-01-01

    Theoretical and experimental investigations of the flow and temperature distribution in a 12.53 m(2) solar collector panel with an absorber consisting of two vertical manifolds interconnected by 16 parallel horizontal fins have been carried out. The investigations are focused on overheating...... and the influence of the buoyancy effects are considered in the investigations. Further experimental investigations of the solar collector panel are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the back of the absorber tubes. The measured temperatures....... The CFD calculations elucidate the flow and temperature distribution in the collector panels of different designs. Based on the investigations, recommendations are given in order to avoid overheating or boiling problems in the solar collector panel....

  4. Development of flat-plate solar collectors for the heating and cooling of buildings

    Science.gov (United States)

    Ramsey, J. W.; Borzoni, J. T.; Holland, T. H.

    1975-01-01

    The relevant design parameters in the fabrication of a solar collector for heating liquids were examined. The objective was to design, fabricate, and test a low-cost, flat-plate solar collector with high collection efficiency, high durability, and requiring little maintenance. Computer-aided math models of the heat transfer processes in the collector assisted in the design. The preferred physical design parameters were determined from a heat transfer standpoint and the absorber panel configuration, the surface treatment of the absorber panel, the type and thickness of insulation, and the number, spacing and material of the covers were defined. Variations of this configuration were identified, prototypes built, and performance tests performed using a solar simulator. Simulated operation of the baseline collector configuration was combined with insolation data for a number of locations and compared with a predicted load to determine the degree of solar utilization.

  5. Development, testing, and certification of Calmac Mfg. Corp. solar collector and solar operated pump

    Science.gov (United States)

    Parker, J. C.

    1979-01-01

    Development of a rubber tube solar collector and solar operated pump for use with solar heating and cooling systems is discussed. The development hardware, problems encountered during fabrication and testing, and certification statements of performance are included.

  6. Ray tracing optical analysis of offset solar collector for space station solar dynamic system

    Science.gov (United States)

    Jefferies, Kent S.

    1988-01-01

    OFFSET, a detailed ray tracing computer code, was developed at NASA Lewis Research Center to model the offset solar collector for the Space Station solar dynamic electric power system. This model traces rays from 50 points on the face of the Sun to 10 points on each of the 456 collector facets. The triangular facets are modeled with spherical, parabolic, or toroidal reflective surface contour and surface slope errors. The rays are then traced through the receiver aperture to the walls of the receiver. Images of the collector and of the Sun within the receiver produced by this code provide insight into the collector receiver interface. Flux distribution on the receiver walls, plotted by this code, is improved by a combination of changes to aperture location and receiver tilt angle. Power loss by spillage at the receiver aperture is computed and is considerably reduced by using toroidal facets.

  7. Ray tracing optical analysis of offset solar collector for Space Station solar dynamic system

    Science.gov (United States)

    Jefferies, Kent S.

    1988-01-01

    OFFSET, a detailed ray tracing computer code, was developed at NASA Lewis Research Center to model the offset solar collector for the Space Station solar dynamic electric power system. This model traces rays from 50 points on the face of the sun to 10 points on each of the 456 collector facets. The triangular facets are modeled with spherical, parabolic, or toroidal reflective surface contour and surface slope errors. The rays are then traced through the receiver aperture to the walls of the receiver. Images of the collector and of the sun within the receiver produced by this code provide insight into the collector receiver interface. Flux distribution on the receiver walls, plotted by this code, is improved by a combination of changes to aperture location and receiver tilt angle. Power loss by spillage at the receiver aperture is computed and is considerably reduced by using toroidal facets.

  8. Thermal performance evaluation of the Suncatcher SH-11 (liquid) solar collector

    Science.gov (United States)

    1980-01-01

    The procedures used and the results obtained during the evaluation test program on the Solar Unlimited, Inc., Suncatcher SH-11 (liquid) solar collector are presented. The flat-plate collector case assembly is made of .08 inch aluminum 3003 H14 riveted with fiberglass board insulation. The absorber consists of collared aluminum fins mechanically bonded to 3/8 inch copper tubing and coated with 3M Nextel black. Water is used as the working fluid. The glazing is made of a single glass, 1/8 inch water white, tempered and antireflective. The collector weight is 85 pounds with overall external dimensions of about 35.4 in x 82.0 in x 4.0 in. Thermal performance data on the Solar Unlimited Suncatcher SH-11 solar collector under simulated conditions were conducted using the MSFC Solar Simulator.

  9. Wind Tunnel Tests of Parabolic Trough Solar Collectors: March 2001--August 2003

    Energy Technology Data Exchange (ETDEWEB)

    Hosoya, N.; Peterka, J. A.; Gee, R. C.; Kearney, D.

    2008-05-01

    Conducted extensive wind-tunnel tests on parabolic trough solar collectors to determine practical wind loads applicable to structural design for stress and deformation, and local component design for concentrator reflectors.

  10. Analysis of the Optimum Solar Collector Installation Angle from the Viewpoint of Energy Use Patterns

    Directory of Open Access Journals (Sweden)

    Yong-Joon Jun

    2017-11-01

    Full Text Available While solar energy is the most efficient energy source for heating, many problems can occur when the capacity selection of the system is wrong: a definite possibility in a place where the seasonal climate change is large, such as Korea. For example, if a system is designed for use in the winter, the system will be overloaded if it does not discard the energy it collects during the summer months. Conversely, if the capacity of the system is in accordance with the summer season demand, it will be necessary to input supplementary energy in the winter season. Solar energy also depends on the altitude and azimuth of the sun, and the amount of energy collected on the slope depends on the latitude of the area in which it is installed. Therefore, this study is divided into investigating the collection energy, heat radiation energy and auxiliary energy input according to the installation angle of the solar collector and the capacity of the heat storage tank according to latitude of the installation area. To this end, we formulate appropriate energy equations. Simulation coding was performed to track the temperature changes in each part. Additionally, we considered the amount of solar energy that can be effectively used, not simply the amount of solar energy collected, by substituting the actual hot water usage schedule.

  11. Development and life cycle analysis of double slope active solar still with flat plate collector

    Directory of Open Access Journals (Sweden)

    A.K. Sethi

    2014-02-01

    Full Text Available Potable water is an essential ingredient of socio-economic development and economic growth. Often water sources are brackish (i.e. contain dissolved salts and/or contain harmful bacteria and therefore cannot be used for drinking. In addition, there are many coastal locations where seawater is abundant but potable water is not available. This study is focused on a development of solar still with flat plat collector for water desalination considered for small scale applications at remote locations where only saline water is available. In this paper the cost of distilled water per kg has been calculated by using the concept of life cycle cost analysis. The pay back periods for different conditions of the distribution of distilled water, namely at the cost it is produced and at the selling price on market rate have been evaluated. The cost of water per kg is minimum Rs. 0.59, when the interest rate and the lifetime of solar still are taken as 4% and 50 years respectively. The lowest payback time 1.23 years is obtained when the selling price of water Rs. 10 per kg.

  12. Experimental study of the scavenging process by means of a sequential precipitation collector, preliminary results

    Science.gov (United States)

    Durana, N.; Casado, H.; Ezcurra, A.; Garcia, C.; Lacaux, J. P.; Van Dinh, Pham

    From January 1986 to July 1989, 103 rain events were sampled with a sequential collector in Vitoria, a moderately industrialized city (Spanish Basque country). Each sample was analysed in terms of pH, conductivity and the ionic concentration of Cl -, NO -3, SO 2-4, NH +4, Na +, K +, Ca 2+ and Mg 2+. On average, the rainwater samples were acid, with a mean pH value of 4.9 the major ions being SO 2-4 and Ca 2+. Events with highly acid characteristics (pH ⩽ 4.5) represent 14% of the total collected. Analysis of meteorological conditions in relation with the average ionic concentrations points out the influence of anthropogenic sources from southwestern France and from the northern Basque country. The decrease in the wet deposition (in percentage of the total deposition per rainfall event) throughout precipitation is particularly apparent for NH +4 and Ca 2+ ions. In precipitation related to the meteorological Local-class, the atmospheric removal appears to be more efficient, especially for Ca 2+, and we can also note a precipitation-neutralizing effect. Precipitation scavenging is mainly controlled by the total amount of water precipitated. However, the intensity of the rain modified the deposition rate.

  13. Control of Hyperbolic Heat Transfer Mechanisms Application to the Distributed Concentrated Solar Collectors

    KAUST Repository

    Elmetennani, Shahrazed

    2017-04-01

    This dissertation addresses the flow control problem in hyperbolic heat transfer mechanisms. It raises in concentrated distributed solar collectors to enhance their production efficiency under the unpredictable variations of the solar energy and the external disturbances. These factors which are either locally measured (the solar irradiance) or inaccessible for measurement (the collectors’ cleanliness) affect the source term of the distributed model and represent a major difficulty for the control design. Moreover, the temperature in the collector can only be measured at the boundaries. In this dissertation, we propose new adaptive control approaches to provide the adequate level of heat while coping with the unpredictable varying disturbances. First, we design model based control strategies for a better efficiency, in terms of accuracy and response time, with a relatively reduced complexity. Second, we enhance the controllers with on-line adaptation laws to continuously update the efficient value of the external conditions. In this study, we approach the control problem using both, the infinite dimensional model (late lumping) and a finite dimensional approximate representation (early lumping). For the early lumping approach, we introduce a new reduced order bilinear approximate model for system analysis and control design. This approximate state representation is then used to derive a nonlinear state feedback resorting to Lyapunov stability theory. To compensate for the external disturbances and the approximation uncertainties, an adaptive controller is developed based on a phenomenological representation of the system dynamics. For the late lumping approach, we propose two PDE based controllers by stabilization of the reference tracking error distributed profile. The control laws are explicitly defined as functions of the available measurement. The first one is obtained using a direct approach for error stabilization while the second one is derived through a

  14. Towards the optimization of the thermal–hydraulic performance of gyrotron collectors

    Energy Technology Data Exchange (ETDEWEB)

    Savoldi, Laura; Bertani, Cristina [Dipartimento Energia, Politecnico di Torino, 10129 Torino (Italy); Cau, Francesca; Cismondi, Fabio [F4E, Barcelona (Spain); Gantenbein, Gerd; Illy, Stefan [Karlsruhe Institute of Technology (KIT), Institute for Pulsed Power and Microwave Technology (IHM), Kaiserstr. 12, 76131 Karlsruhe (Germany); Monni, Grazia [Dipartimento Energia, Politecnico di Torino, 10129 Torino (Italy); Rozier, Yoann [Thales Electron Devices, 78141 Vélizy-Villacoublay (France); Zanino, Roberto, E-mail: roberto.zanino@polito.it [Dipartimento Energia, Politecnico di Torino, 10129 Torino (Italy)

    2015-11-15

    Different configurations of water-cooled Cu collector for gyrotrons are investigated using the StarCCM + CFD code, aimed at optimizing its thermal–hydraulic (TH) performance. Although the current collectors show a good performance, the collector can be subjected to transient heat loads, due to the spent electron beam, of up to several tens of MW/m{sup 2}, and there is an interest to increase the gyrotron output power in the future. Furthermore, an optimized cooling will lead to improved reliability and lifetime of the collector. Starting from a hypervapotron (HV)-like collector, characterized by 100+ deep rectangular cavities with aspect ratio (AR) = 3, we present in the first part of the paper a single-cavity steady-state parametric analysis of the effect of AR on the heat exhaust capabilities. The investigation is then extended to other collector designs, including circumferential ribs and dimples, in order to assess the options for further improvements of the TH performance. The peak Cu temperature is computed by the code and its minimization is the target of the present optimization exercise. A self-consistent estimate of the heat transfer coefficient between collector and coolant is also obtained, which could be useful for fatigue and lifetime assessments. In the second part of the paper the most promising collector geometries identified in the first part are analyzed in the case of a transient heat load (vertical sweeping), first at the level of a single spatial period of the collector structure, then at the full-collector level. The results of the TH transient analysis are compared with both the results of the first part and with the transient purely thermal analysis of the full collector, showing for all geometries considered in this study a room for cooling efficiency improvement with respect to the HV-like design with AR = 3, at least in the operating conditions considered for this study (V ∼ 4 m/s, almost 100 °C sub-cooling).

  15. Protocol of measurement techniques - Project colored solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, A.; Chambrier, E. De; Roecker, Ch.; Scartezzini, J.-L.

    2004-08-15

    This illustrated annual report for the Swiss Federal Office of Energy (SFOE) takes a look at work done at the Swiss Federal Institute of Technology in Lausanne, Switzerland, on multi-layer, thin-film interference coatings for solar collector glazing. The correct combinations of refractive indices and film thickness are discussed. The authors state that corresponding multi-layered thin film stacks will have to be realised experimentally in a controlled and reproducible way. New thin film materials are to be tailored to exhibit optimised optical and ageing properties. The development of these coatings is to be based on various measurement techniques, such as spectro-photometry, measurements of total power throughput by means of a solar simulator, spectroscopic ellipsometry, scanning electron microscopy (SEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). The paper provides many examples of typical data and explains which film properties can be inferred from each method and thus describes both the function and purpose of the different measurement techniques.

  16. Failure analysis of collector circuits associated with wind farms

    Directory of Open Access Journals (Sweden)

    Clifton Ashley P.

    2017-01-01

    Full Text Available Wind farm collector circuits generally comprise several wind turbine generators (WTG’s. WTG’s are connected in parallel to a substation. This connection acts as the point-of-connection to the national electricity grid. The electrical load in these circuits is close to component (power cables and accessories ratings. The objective of this paper is to identify cable joint failure paths; and, develop an understanding of specific contributing factors. All findings presented were established from literature review involving data analysis and discussion with industry experts working across the wind industry. Application of forces, inadequate workmanship, incorrect thermal resistance or other contributing factors, all contribute to high conductor operating temperatures. High conductor operating temperatures highlight issues including insufficient environmental heat transfer due to the use of inadequate cable trenching materials. This in turn results in the imbalanced application of force, experienced at the cable joint, as a direct result of frequent thermal expansion and contraction. For most cable joint failures, the root cause is insulation breakdown due to sustained deterioration of the cross-linked polyethylene insulation. This is a direct result from excessive operating temperatures.

  17. Grid collector an event catalog with automated file management

    CERN Document Server

    Ke Sheng Wu; Sim, A; Jun Min Gu; Shoshani, A

    2004-01-01

    High Energy Nuclear Physics (HENP) experiments such as STAR at BNL and ATLAS at CERN produce large amounts of data that are stored as files on mass storage systems in computer centers. In these files, the basic unit of data is an event. Analysis is typically performed on a selected set of events. The files containing these events have to be located, copied from mass storage systems to disks before analysis, and removed when no longer needed. These file management tasks are tedious and time consuming. Typically, all events contained in the files are read into memory before a selection is made. Since the time to read the events dominate the overall execution time, reading the unwanted event needlessly increases the analysis time. The Grid Collector is a set of software modules that works together to address these two issues. It automates the file management tasks and provides "direct" access to the selected events for analyses. It is currently integrated with the STAR analysis framework. The users can select ev...

  18. Nanofluid optical property characterization: towards efficient direct absorption solar collectors

    Directory of Open Access Journals (Sweden)

    Otanicar Todd

    2011-01-01

    Full Text Available Abstract Suspensions of nanoparticles (i.e., particles with diameters < 100 nm in liquids, termed nanofluids, show remarkable thermal and optical property changes from the base liquid at low particle loadings. Recent studies also indicate that selected nanofluids may improve the efficiency of direct absorption solar thermal collectors. To determine the effectiveness of nanofluids in solar applications, their ability to convert light energy to thermal energy must be known. That is, their absorption of the solar spectrum must be established. Accordingly, this study compares model predictions to spectroscopic measurements of extinction coefficients over wavelengths that are important for solar energy (0.25 to 2.5 μm. A simple addition of the base fluid and nanoparticle extinction coefficients is applied as an approximation of the effective nanofluid extinction coefficient. Comparisons with measured extinction coefficients reveal that the approximation works well with water-based nanofluids containing graphite nanoparticles but less well with metallic nanoparticles and/or oil-based fluids. For the materials used in this study, over 95% of incoming sunlight can be absorbed (in a nanofluid thickness ≥10 cm with extremely low nanoparticle volume fractions - less than 1 × 10-5, or 10 parts per million. Thus, nanofluids could be used to absorb sunlight with a negligible amount of viscosity and/or density (read: pumping power increase.

  19. Photocatalytic disinfection of water using low cost compound parabolic collectors

    Energy Technology Data Exchange (ETDEWEB)

    McLoughlin, O.A.; Gill, L.W. [Dublin Univ. (Ireland). Dept. of Civil, Structural and Environmental Engineering; Ibanez, F.; Gernjak, W.; Malato Rodriguez, S. [Plataforma Solar de Almeria (CIEMAT), Tabemas (Spain)

    2004-11-01

    The objective of this work was to assess the effectiveness of using near UV light to disinfect water supplies for potential applications in developing countries. A pilot scale photoreactor comprised of non-tracking compound parabolic collectors installed at Plataforma Solar de Almeria was examined and a comparison of disinfection efficiency using E. coli K-12 was carried out with a reactor configuration of 3 and 1 m{sup 2} illuminated area. Tests were also carried out using suspensions of titanium dioxide (TiO{sub 2}) at concentrations ranging from 0 to 9 mg/l. The removal of E. coli K-12 from initial concentrations of 1 x 10{sup 5} CFU/ml to below the limit of detection was achieved both with and without the use of TiO{sub 2}. Levels of inactivation in 35 l of inoculated water of up to 4-log removal were achieved in under 30 min. The addition of TiO{sub 2} created an enhancement to the process only at the 3 mg/l dose. However, the results have also suggested the possibility that another disinfection mechanism, possibly governed by the frequency of intermittent UV light exposure, was regulating the overall inactivation kinetics of the trials. (Author)

  20. Metal-free current collectors based on graphene materials for supecapacitors produced by 3D printing

    Science.gov (United States)

    Baskakov, S. A.; Baskakova, Yu. V.; Lyskov, N. V.; Dremova, N. N.; Shul'ga, Yu. M.

    2017-10-01

    Supercapacitor (SC) current collectors with electrodes made of graphite oxide reduced during microwave exfoliation are produced from a commercial filament with a graphene component via layer-by-layer fusing with a 3D printer. The separator is made of a graphene oxide film. The current collectors are investigated by means of IR spectroscopy. Electrochemical tests are performed for the assembled SC that include tests of its cyclic stability up to 1000 cycles.

  1. Methods to Reduce the Risk to Wind Action of the Fixing Systems of Sollar Collectors

    OpenAIRE

    Elena Axinte; Elena-Carmen Teleman; Victoria-Elena Roşca; Georgeta Vasieş

    2010-01-01

    The interest in the non-conventional energy resources, a consequence of the severe restrictions imposed towards pollution of any kind, arises again the interest in using solar collectors. Implanting them on the terraces of new or existent home residencies, or any kind of other buildings, means to solve a sum of engineering problems, among them being also the stages of safely designing the plane panels for collectors and the sustaining skeleton, made in steel as well as the fixing systems adop...

  2. DESIGN AND IMPLEMENTATION SINGLE AXIS TRACKER MODEL BASED ON MICROCONTROLLER FOR SOLAR COLLECTOR

    OpenAIRE

    Saad T. Hamidi; Ekbal Hussein Ali; Noor Shakeeb Hassan

    2017-01-01

    ABSTRACT :- The present work is a design and implementation of a compact single-axes solar tracking system. The hybrid system a combination from mechanical and the electronic parts. A tracking system are used to track the sun position and let the solar collector facing the sun as long as possible. The single axis tracking system has the ability to rotate the solar collector in horizontal axis and in both clockwise and anticlockwise .The electronic system contains a microcont...

  3. Incidence angle modifiers in cylindrical solar collector design. Final report, June 1996--May 1997

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, J.P.

    1997-05-01

    This thesis presents an analysis of the thermal performance of cylindrical solar collectors. A major contributor to performance is optics, the principle focus of this work. A tool used to compute the incidence angle modifiers (IAM`s) for cylindrical solar collectors is presented. The Monte Carlo Method is employed in a Fortran 90 computer code to compute the hemispheric IAM`s of cylindrical solar collectors. Using concentric cylinders, the tubes are modeled with and without back plane reflectors of varying size. The computed IAM`s are verified both analytically and experimentally. Outdoor experiments on an array of cylindrical tubes with various back planes and two different tube spacings are described. Agreement with TRNSYS runs in daily energy gain is excellent. Over the 38 data sets, taken on different days, a maximum error of 11.2% is observed, with an average error of 3%. Heat loss tests, used to calculate an overall heat loss coefficient for the collector, are also described. A parametric variation study is used to illustrate the effect of varying many of the collector parameters. This study provides insight into the significant design parameters for cylindrical solar collectors. This insight is used to analyze the effect of these design parameters on the annual energy delivered by the collector. In addition, a simple cost analysis illustrates the benefits of varying the design parameters. The use of this new program and a detailed Life Cycle Cost analysis are the tools needed for optimizing the design of a cylindrical solar collector. 27 figs., 9 tabs.

  4. Reduction of Fire Hazard in Materials for Irrigators and Water Collectors in Cooling Towers

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, N. V.; Konstantinova, N. I., E-mail: konstantinova-n@inbox.ru [FGBU VNIIPO of EMERCOM of Russia (All-Russian Scientific-research Institute of Fire Protection) (Russian Federation); Gordon, E. P. [Research and Production Center “Kaustik” (Russian Federation); Poedintsev, E. A. [FGBU VNIIPO of EMERCOM of Russia (All-Russian Scientific-research Institute of Fire Protection) (Russian Federation)

    2016-09-15

    A way of reducing the fire hazard of PVC film used to make cooling-tower irrigators and water collectors is examined. A new generation of fire retardant, nanostructured magnesium hydroxide, is used to impart fire retardant properties. The fabrication technology is optimized with a roller-calendering manufacturing technique, and the permissible ranges of fire hazard indicators for materials in irrigators and water collectors are determined.

  5. Comparison between theoretical analyses and experimental results of two-phase closed thermosyphons solar collector

    Energy Technology Data Exchange (ETDEWEB)

    Sayegh, M.A. [Faculty of Mechanical Engineering, Univ. Aleppo (Syrian Arab Republic); Danielewicz, J.; Nowak, B. [Faculty of Heating and Air Conditioning, Techn. Univ. of Wroclaw (Poland)

    1996-12-31

    The observed experimental results of the heated water temperature runs in the solar collector with TPCT for water heating systems are compared with results of numerical simulation. A compact system for hot water preparation with absorbing and accumulating the heat was analysed. In study the influence of the thermal resistance of TPCT on the heat removal factor F{sub R} and collector thermal efficiency is also presented. (orig.)

  6. 3X compound parabolic concentrating (CPC) solar energy collector. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Ballheim, R.W.

    1980-04-25

    Chamberlain engineers designed a 3X compound parabolic concentrating (CPC) collector for the subject contract. The collector is a completely housed, 105.75 x 44.75 x 10.23-inch, 240-pound unit with six each evacuated receiver assemblies, a center manifold and a one-piece glass cover. A truncated version of a CPC trough reflector system and the General Electric Company tubular evacuated receiver have been integrated with a mass producible collector design suitable for operation at 250 to 450/sup 0/F. The key criterion for optimization of the design was minimization of the cost per Btu collected annually at an operating temperature of 400/sup 0/F. The reflector is a 4.1X design truncated to a total height of 8.0 inches with a resulting actual concentration ratio of 2.6 to 1. The manifold is an insulated area housing the fluid lines which connect the six receivers in series with inlet and outlet tubes extending from one side of the collector at the center. The reflectors are polished, anodized aluminum which are shaped by the roll form process. The housing is painted, galvanized steel, and the cover glass is 3/16-inch thick tempered, low iron glass. The collector requires four slope adjustments per year for optimum effectiveness. Chamberlain produced ten 3X CPC collectors for the subject contract. Two collectors were used to evaluate assembly procedures, six were sent to the project officer in Albuquerque, New Mexico, one was sent to Argonne National Laboratory for performance testing and one remained with the Company. A manufacturing cost study was conducted to estimate limited mass production costs, explore cost reduction ideas and define tooling requirements. The final effort discussed shows the preliminary design for application of a 3X CPC solar collector system for use in the Iowa State Capitol complex.

  7. Micro-V covering materials with high light transmittance for solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Sonneveld, P.J.; Swinkels, G.L.A.M. [Wageningen UR, A and F (Netherlands)

    2004-07-01

    Maximal light transmittance of the covering material is important for solar collectors maximising yield of the system. Furthermore a second sheet of covering material can be applied with low light loss to increase thermal insulation. Therefore research is aimed at improving light transmission. Ray tracing method has been applied to design the optimal geometry of the material. Light transmission, thermal insulation, structural performance and yield aspects of solar collectors are combined in this research with glass as basic covering material. (orig.)

  8. Architectural integration of energy solar collectors made with ceramic materials and suitable for the Mediterranean climate

    Directory of Open Access Journals (Sweden)

    J. Roviras

    2016-12-01

    Full Text Available The work presented here aims to demonstrate the technical, architectural and energy viability of solar thermal collectors made with ceramic materials and the Mediterranean climate suitable for the production of domestic hot water (DHW and for heating systems in buildings. The design of a ceramic shell formed by panels collectors and panels no sensors, which are part of the same building system that is capable of responding to the basic requirements of a building envelope and capture solar energy is proposed. Ceramics considerably reduced the final cost of the sensor system and offers the new system a variety of compositional and chromatic since, with reduced performance compared to a conventional metallic collector, can occupy the entire surface of front and get a high degree of architectural integration. A tool for assessing the new ceramic solar collector has been defined from a multi-criteria perspective: economic, environmental and social. The tool enables the comparison of the ceramic solar collector with solar collectors on the market under different climatic and demand conditions.

  9. Performance Evaluation of a Nanofluid-Based Direct Absorption Solar Collector with Parabolic Trough Concentrator

    Directory of Open Access Journals (Sweden)

    Guoying Xu

    2015-12-01

    Full Text Available Application of solar collectors for hot water supply, space heating, and cooling plays a significant role in reducing building energy consumption. For conventional solar collectors, solar radiation is absorbed by spectral selective coating on the collectors’ tube/plate wall. The poor durability of the coating can lead to an increased manufacturing cost and unreliability for a solar collector operated at a higher temperature. Therefore, a novel nanofluid-based direct absorption solar collector (NDASC employing uncoated collector tubes has been proposed, and its operating characteristics for medium-temperature solar collection were theoretically and experimentally studied in this paper. CuO/oil nanofluid was prepared and used as working fluid of the NDASC. The heat-transfer mechanism of the NDASC with parabolic trough concentrator was theoretically evaluated and compared with a conventional indirect absorption solar collector (IASC. The theoretical analysis results suggested that the fluid’s temperature distribution in the NDASC was much more uniform than that in the IASC, and an enhanced collection efficiency could be achieved for the NDASC operated within a preferred working temperature range. To demonstrate the feasibility of the proposed NDASC, experimental performances of an NDASC and an IASC with the same parabolic trough concentrator were furthermore evaluated and comparatively discussed.

  10. Experimental and Numerical Analyses of a Flat Plate Photovoltaic/Thermal Solar Collector

    Directory of Open Access Journals (Sweden)

    Francesco Calise

    2017-04-01

    Full Text Available This paper presents a one-dimensional finite-volume model of an unglazed photovoltaic/thermal (PVT solar collector. The unit consists of a conventional solar photovoltaic (PV collector coupled with a suitable heat exchanger. In particular, the collector includes a roll bond heat exchanger and it is not equipped with back and frame insulation. The system is discretized along the flow direction (longitudinal of the cogenerative collector. For each finite-volume element of the discretized computational domain, mass and energy balances are implemented. The collector geometry and materials parameters are taken from a commercially available device. An on-field experimental investigation is performed in order to validate the proposed model. The model is used to evaluate both electrical and thermodynamic parameters for each element of the domain and for fixed operating conditions. Finally, a sensitivity analysis is also performed in order to investigate the energetic performance of the cogenerative collector as a function of the main design/environmental parameters.

  11. Optimizing the shape of a surge-and-pitch wave energy collector using a genetic algorithm

    Energy Technology Data Exchange (ETDEWEB)

    McCabe, A.P.; Aggidis, G.A.; Widden, M.B. [Engineering Department, Renewable Energy Research Group, Lancaster University, Lancaster LA1 4YR (United Kingdom)

    2010-12-15

    This study forms part of research into the optimization of the shape of a wave energy collector to improve energy extraction using genetic algorithms. The wave energy collector geometry uses a parametric description based upon bi-cubic B-spline surfaces, generated from a relatively small number of control points to reduce the dimensionality of the search space. The collector shapes that are optimized have either one or two planes of symmetry. An elementary cost function is used to determine the performance of each candidate solution. The collectors move in two degrees of freedom (surge-and-pitch), and are optimally tuned to absorb the greatest power from a number of incident regular waves, the results being weighted according to a generalized occurrence distribution. High velocities and large collector volumes are penalized. A benchmark collector shape, against which the optimized shapes are compared, is identified. The overall optimization strategy entails performing repeated runs of the algorithm for a fixed number of generations, then restarting the optimization with the run that produces the best result. An appraisal of the results is made, looking at the performance of all the shapes assessed as well as those deemed the best. (author)

  12. Heat transfer in a low latitude flat-plate solar collector

    Directory of Open Access Journals (Sweden)

    Oko C.O.C.

    2012-01-01

    Full Text Available Study of rate of heat transfer in a flat-plate solar collector is the main subject of this paper. Measurements of collector and working fluid temperatures were carried out for one year covering the harmattan and rainy seasons in Port Harcourt, Nigeria, which is situated at the latitude of 4.858oN and longitude of 8.372oE. Energy balance equations for heat exchanger were employed to develop a mathematical model which relates the working fluid temperature with the vital collector geometric and physical design parameters. The exit fluid temperature was used to compute the rate of heat transfer to the working fluid and the efficiency of the transfer. The optimum fluid temperatures obtained for the harmattan, rainy and yearly (or combined seasons were: 317.4, 314.9 and 316.2 [K], respectively. The corresponding insolation utilized were: 83.23, 76.61 and 79.92 [W/m2], respectively, with the corresponding mean collector efficiency of 0.190, 0.205 and 0.197 [-], respectively. The working fluid flowrate, the collector length and the range of time that gave rise to maximum results were: 0.0093 [kg/s], 2.0 [m] and 12PM - 13.00PM, respectively. There was good agreement between the computed and the measured working fluid temperatures. The results obtained are useful for the optimal design of the solar collector and its operations.

  13. LPP EUV source readiness for NXE 3300B

    Science.gov (United States)

    Brandt, David C.; Fomenkov, Igor V.; Farrar, Nigel R.; La Fontaine, Bruno; Myers, David W.; Brown, Daniel J.; Ershov, Alex I.; Böwering, Norbert R.; Riggs, Daniel J.; Rafac, Robert J.; De Dea, Silvia; Peeters, Rudy; Meiling, Hans; Harned, Noreen; Smith, Daniel; Pirati, Alberto; Kazinczi, Robert

    2014-03-01

    Laser produced plasma (LPP) light sources have been developed as the primary approach for EUV scanner imaging of circuit features in sub-20nm devices in high volume manufacturing (HVM). This paper provides a review of development progress and readiness status for the LPP extreme-ultra-violet (EUV) source. We present the latest performance results from second generation sources, including Prepulse operation for high power, collector protection for long lifetime and low cost of ownership, and dose stability for high yield. Increased EUV power is provided by a more powerful drive laser and the use of Prepulse operation for higher conversion efficiciency. Advanced automation and controls have been developed to provide the power and energy stability performance required during production fab operation. We will also discuss lifetesting of the collector in Prepulse mode and show the ability of the debris mitigation systems to keep the collector multi-layer coating free from damage and maintain high reflectivity.

  14. COMBINED UNCOVERED SHEET-AND-TUBE PVT-COLLECTOR SYSTEM WITH BUILT-IN STORAGE WATER HEATER

    Directory of Open Access Journals (Sweden)

    Muhammad Abid

    2012-02-01

    Full Text Available This work describes the design and investigation of a simple combined uncovered sheet-and-tube photo-voltaic-thermal (PVT collector system. The PVT-collector system consists of a support, standard PV module (1.22x0.305m, area=0.37m2, fill factor=0.75, sheet-and-tube water collector and storage tank-heater. The collector was fixed under PV module. Inclination angle of the PVT-collector to the horizontal plane was 45 degree. The storage tank-heater played double role i.e. for storage of hot water and for water heating. The PVT-collector system could work in the fixed and tracking modes of operation. During investigations of PVT-collector in natural conditions, solar irradiance, voltage and current of PV module, ambient temperature and water temperature in storage tank were measured. Average thermal and electrical powers of the PVT-collector system at the tracking mode of operation observed were 39W and 21W, with efficiencies of 15% and 8% respectively at the input power of 260W. The maximum temperature of the water obtained was 42oC. The system was observed efficient for low-temperature applications. The PVT-collector system may be used as a prototype for design of PVT-collector system for domestic application, teaching aid and for demonstration purposes.

  15. Experimental and CFD studies on SnO2 coatings over solar cells to increase collector efficiency

    Science.gov (United States)

    Vinutha, A.; Anvesh, C. H. Venkata; Babu, R. Art; Sarma, P. N.

    2017-07-01

    Solar radiation is major outcome of renewable energy sources. The low overall efficiency (21%) in solar collectors is mainly due to the reflection of the heat absorbed from the solar cells back to atmospheric air. Experiments are conducted to apply a Nano-coating layer of tin oxide on solar cells (silicon wafers) by a thermal vapour process under high vacuum, followed by annealing with an objective of reducing the reflection. The tests conducted with the Nano-coated solar cells showed that the cell efficiency has increased from 24% without coating to 31% with an optimum coating 400 nm thicknesses has been found. As the coating thickness is increased from zero to 600nm the heat loss due to convection decreased monotonically from 461.4 to 452 W/m2. The CFD analysis provides the temperature distribution in the solar panel and heat transferred to base for effective heat re-utilization.

  16. Experimental investigation of a nanofluid absorber employed in a low-profile, concentrated solar thermal collector

    Science.gov (United States)

    Li, Qiyuan; Zheng, Cheng; Mesgari, Sara; Hewakuruppu, Yasitha L.; Hjerrild, Natasha; Crisostomo, Felipe; Morrison, Karl; Woffenden, Albert; Rosengarten, Gary; Scott, Jason A.; Taylor, Robert A.

    2015-12-01

    Recent studies [1-3] have demonstrated that nanotechnology, in the form of nanoparticles suspended in water and organic liquids, can be employed to enhance solar collection via direct volumetric absorbers. However, current nanofluid solar collector experimental studies are either relevant to low-temperature flat plate solar collectors (100 °C) indoor laboratory-scale concentrating solar collectors [1, 5]. Moreover, many of these studies involve in thermal properties of nanofluid (such as thermal conductivity) enhancement in solar collectors by using conventional selective coated steel/copper tube receivers [6], and no full-scale concentrating collector has been tested at outdoor condition by employing nanofluid absorber [2, 6]. Thus, there is a need of experimental researches to evaluate the exact performance of full-scale concentrating solar collector by employing nanofluids absorber at outdoor condition. As reported previously [7-9], a low profile (solar thermal concentrating collector was designed and analysed which can potentially supply thermal energy in the 100-250 °C range (an application currently met by gas and electricity). The present study focuses on the design and experimental investigation of a nanofluid absorber employed in this newly designed collector. The nanofluid absorber consists of glass tubes used to contain chemically functionalized multi-walled carbon nanotubes (MWCNTs) dispersed in DI water. MWCNTs (average diameter of 6-13 nm and average length of 2.5-20 μm) were functionalized by potassium persulfate as an oxidant. The nanofluids were prepared with a MCWNT concentration of 50 +/- 0.1 mg/L to form a balance between solar absorption depth and viscosity (e.g. pumping power). Moreover, experimentally comparison of the thermal efficiency between two receivers (a black chrome-coated copper tube versus a MWCNT nanofluid contained within a glass tubetube) is investigated. Thermal experimentation reveals that while the collector efficiency

  17. MERCURY CONTROL WITH THE ADVANCED HYBRID PARTICULATE COLLECTOR

    Energy Technology Data Exchange (ETDEWEB)

    Ye Zhuang; Stanley J. Miller; Grant E. Dunham; Michelle R. Olderbak

    2002-02-01

    Since 1995, DOE has supported development of a new concept in particulate control, called the advanced hybrid particulate collector (AHPC). The AHPC combines the best features of electrostatic precipitators (ESPs) and baghouses in a unique configuration, providing major synergism between the two collection methods, both in the particulate collection step and in the transfer of dust to the hopper. The AHPC provides ultrahigh collection efficiency, overcoming the problem of excessive fine-particle emission with conventional ESPs, and it solves the problem of reentrainment and re-collection of dust in conventional baghouses. The AHPC appears to have unique advantages for mercury control over baghouses or ESPs as an excellent gas-solid contactor. The objective of the three-task project is to demonstrate 90% total mercury control in the AHPC at a lower cost than current mercury control estimates. The approach includes bench-scale batch testing that ties the new work to previous results and links results with larger-scale pilot testing with real flue gas on a coal-fired combustion system, pilot-scale testing on a coal-fired combustion system with both a pulse-jet baghouse and an AHPC to prove or disprove the research hypotheses, and field demonstration pilot-scale testing at a utility power plant to prove scaleup and demonstrate longer-term mercury control. This project, if successful, will demonstrate at the pilot-scale level a technology that would provide a cost-effective technique to accomplish control of mercury emissions and, at the same time, greatly enhance fine particulate collection efficiency. The technology can be used to retrofit systems currently employing inefficient ESP technology as well as for new construction, thereby providing a solution to a large segment of the U.S. utility industry as well as other industries requiring mercury control.

  18. The effects of source credibility and salience on sales performance: a study of corporate art collectors

    NARCIS (Netherlands)

    Kackovic, M.; Ebbers, J.J.; Wijnberg, N.M.; Kubacki, K.

    2015-01-01

    Signaling theory (Spence, 1973) focuses on using signals as proxies of quality and helps explain how signals reduce uncertainties in pre-purchase decision-making. Signals convey information about a product or producer’s unobservable or indiscernible quality (Kirmani and Rao, 2000), and are important

  19. Evaluation of the potential of optical switching materials for overheating protection of thermal solar collectors - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Huot, G.; Roecker, Ch.; Schueler, A.

    2008-01-15

    Providing renewable energy for domestic hot water production and space heating, thermal solar collectors are more and more widespread, and users' expectations with respect to performance and service lifetime are rising continuously. The durability of solar collector materials is a critical point as the collector lifetime should be at least 25 years. Overheating and the resulting stagnation of the collector is a common problem with solar thermal systems. During stagnation high temperatures lead to water evaporation, glycol degradation, and stresses in the collector with increasing pressure. Special precautions are necessary to release this pressure; only mechanical solutions exist nowadays. Additionally, the occurring elevated temperatures lead to degradation of the materials that compose collectors: seals, insulation materials, and also the selective coating which is the most important part of the collector. A promising way to achieve active cooling of collectors without any mechanical device for pressure release or collector emptying is to produce a selective coating which is able to switch its optical properties at a critical temperature Tc. An optical switch allows changing the selective coating efficiency; the goal is to obtain a coating with a poor selectivity above Tc (decreasing of absorptance, increasing of emittance). Obtaining self-cooling collectors will allow increasing collector surfaces on facades and roofs in order to get high efficiency and hot water production during winter without inconvenient overheating during summer. Optical switching of materials can be obtained by many ways. Inorganic and organic thermochromic compounds, and organic thermotropic coatings are the main types of switching coatings that have been studied at EPFL-LESO-PB. Aging studies of organic thermochromic paints fabricated at EPFL suggest that the durability of organic compounds might not be sufficient for glazed metallic collectors. First samples of inorganic coatings

  20. Analyser av effektivitet til nyutviklet solfanger i polymermateriale = Analyses of the efficiency for a new polymer solar collector

    OpenAIRE

    Schakenda, Jeanette A.

    2004-01-01

    In this thesis, variations in efficiency between two different solar collectors have been measured. Solar collector efficiency has been measured at different levels of flow. In addition, there has been made calculations of heat gained by the solar system in the course of a day. The effect of reduced transmission at an increasing angle of incidence, has been discussed. Comparisons of the two models show a minor improvement in efficiency in the latest solar collector models. Comparing dai...

  1. Numerical characterisation of one-step and three-step solar air heating collectors used for cocoa bean solar drying.

    Science.gov (United States)

    Orbegoso, Elder Mendoza; Saavedra, Rafael; Marcelo, Daniel; La Madrid, Raúl

    2017-12-01

    In the northern coastal and jungle areas of Peru, cocoa beans are dried using artisan methods, such as direct exposure to sunlight. This traditional process is time intensive, leading to a reduction in productivity and, therefore, delays in delivery times. The present study was intended to numerically characterise the thermal behaviour of three configurations of solar air heating collectors in order to determine which demonstrated the best thermal performance under several controlled operating conditions. For this purpose, a computational fluid dynamics model was developed to describe the simultaneous convective and radiative heat transfer phenomena under several operation conditions. The constructed computational fluid dynamics model was firstly validated through comparison with the data measurements of a one-step solar air heating collector. We then simulated two further three-step solar air heating collectors in order to identify which demonstrated the best thermal performance in terms of outlet air temperature and thermal efficiency. The numerical results show that under the same solar irradiation area of exposition and operating conditions, the three-step solar air heating collector with the collector plate mounted between the second and third channels was 67% more thermally efficient compared to the one-step solar air heating collector. This is because the air exposition with the surface of the collector plate for the three-step solar air heating collector former device was twice than the one-step solar air heating collector. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Long-term weathering effects on the thermal performance of the Solargenics (liquid) solar collector at outdoor conditions

    Energy Technology Data Exchange (ETDEWEB)

    1979-07-01

    The test procedures used and the results obtained during the evaluation test program of the Solargenics single-covered liquid solar collector are presented. The tests were performed under outdoor natural conditions at the Solar Test Facility at MSFC, following long-term exposure to natural weathering conditions. The collector was under stagnation conditions from August 26, 1978, to June 13, 1979, for a total of approximately ten months. The Solargenics solar collector is a liquid, single-glazed, flat-plate collector, and is about 240 inches long, 38 inches wide, and 3.8 inches in depth.

  3. Harmonization of standards for parabolic trough collector testing in solar thermal power plants

    Science.gov (United States)

    Sallaberry, Fabienne; Valenzuela, Loreto; Palacin, Luis G.; Leon, Javier; Fischer, Stephan; Bohren, Andreas

    2017-06-01

    The technology of parabolic trough collectors (PTC) is used widely in concentrating Solar Power (CSP) plants worldwide. However this type of large-size collectors cannot be officially tested by an accredited laboratory and certified by an accredited certification body so far, as there is no standard adapted to its particularity, and the current published standard for solar thermal collectors are not completely applicable to them. Recently some standardization committees have been working on this technology. This paper aims to give a summary of the standardized testing methodology of large-size PTC for CSP plants, giving the physical model chosen for modeling the thermal performance of the collector in the new revision of standard ISO 9806 and the points still to be improved in the standard draft IEC 62862-3-2. In this paper, a summary of the testing validation performed on one parabolic trough collector installed in one of the test facilities at the Plataforma Solar de Almería (PSA) with this new model is also presented.

  4. Experimental analysis of thermal performance according to heat pipe working fluids for evacuated tube solar collector

    Science.gov (United States)

    Joo, Hong-Jin; Kwak, Hee-Youl

    2017-11-01

    The purpose of this study was to experimentally investigate the thermal performance and operating characteristics of various heat pipe working fluids in evacuated tube solar collectors. Heat pipe efficiency was evaluated by calculating the solar collector efficiency value when using four types of working fluids: water, ethanol, flutec-pp9 and methyl acetate under the same operating conditions on an indoor experiment apparatus. The experimental conditions were as follows: The inclination angle of the evacuated tube solar collectors were 20°, 40° and 60° from the normal basis. The mass flow rate into the manifold of the evacuated tubular solar collector was 0.3 kg/min. The heat flux on the collector surface was 870 W/m2. The results showed that, at an angle of incidence of 40°, the values of {F}R ( {τ α } ) and {F}R {U}L with methyl acetate as the working fluid were 0.6572 and -2.0086, respectively, with water they were 0.6636 and -1.8457, respectively, ethanol they were 0.6147 and -0.6353, respectively, and with flutec-pp9 they were 0.525, and -3.2313, respectively.

  5. A new concept of hybrid photovoltaic thermal (PVT) collector with natural circulation

    Science.gov (United States)

    Lu, Longsheng; Wang, Xiaowu; Wang, Shuai; Liu, Xiaokang

    2017-07-01

    Hybrid photovoltaic thermal (PVT) technology refers to the integration of a photovoltaic module into a conventional solar thermal collector. Generally, the traditional design of a PVT collector has solar cells fixed on the top surface of an absorber in a flat-plate solar thermal collector. In this work, we presented a new concept of water-based PVT collector in which solar cells were directly placed on the bottom surface of its glass cover. A dynamic numerical model of this new PVT is developed and validated by experimental tests. With numerical analysis, it is found that at same covering factor, the electricity conversion efficiency of solar cells of the new PVT exceed that of the traditional PVT by nearly 10% while its thermal efficiency is approximately 30% lower than that of the traditional PVT. When the covering factor changes from 0.05 to 1, the thermal efficiency of the new PVT drops nearly 70%. The thermal efficiency of both the new PVT and the traditional PVT rise up as the water mass in tank increases. Meanwhile, the final water temperature in tank of the traditional PVT collector declines more than 17 °C, whereas that of the new PVT declines less than 6 °C, when the water mass increases from 100 to 300 kg.

  6. Design and Testing of a Shell-Encapsulated Solar Collector with the Compound Surface Concentrators

    Directory of Open Access Journals (Sweden)

    Hongfei Zheng

    2015-01-01

    Full Text Available This paper presents design and testing of a shell-encapsulated solar collector which can be used in north area of China for wall-amounting installation. The designed solar collector is based on the combination of a novel compound curved surface concentrator and an aluminum concentric solar receiver, which is contained in a glass evacuated-tube. As there is no perforative joint between the double-skin glass evacuated-tube and the aluminum concentric solar receiver, the difficulty of vacuum keeping for a glass-metal joint is avoided. The cavity shell provides an additional thermal insulation to reduce heat loss of the designed solar collector. The working principle of the compound curved surface concentrator is described. The ray-tracing results are given to show the effect of deviation angle of the concentrator on its optical efficiency, hence determining its maximum acceptance angle. A prototype of the designed solar collector has been constructed and tested under the sunny winter weather condition. The experimental results indicate that the hot water temperature higher than 80°C with a daily average efficiency of about 45~50% has been achieved at the average ambient temperature below 0°C, so the designed solar collector can produce hot water at a useful temperature in winter.

  7. Small-Scale Flat Plate Collectors for Solar Thermal Scavenging in Low Conductivity Environments

    Directory of Open Access Journals (Sweden)

    Emmanuel Ogbonnaya

    2017-01-01

    Full Text Available There is great opportunity to develop power supplies for autonomous application on the small scale. For example, remote environmental sensors may be powered through the harvesting of ambient thermal energy and heating of a thermoelectric generator. This work investigates a small-scale (centimeters solar thermal collector designed for this application. The absorber is coated with a unique selective coating and then studied in a low pressure environment to increase performance. A numerical model that is used to predict the performance of the collector plate is developed. This is validated based on benchtop testing of a fabricated collector plate in a low-pressure enclosure. Model results indicate that simulated solar input of about 800 W/m2 results in a collector plate temperature of 298 K in ambient conditions and up to 388 K in vacuum. The model also predicts the various losses in W/m2 K from the plate to the surroundings. Plate temperature is validated through the experimental work showing that the model is useful to the future design of these small-scale solar thermal energy collectors.

  8. Effect of Installation of Solar Collector on Performance of Balcony Split Type Solar Water Heaters

    Directory of Open Access Journals (Sweden)

    Xu Ji

    2015-01-01

    Full Text Available The influences of surface orientation and slope of solar collectors on solar radiation collection of balcony split type solar water heaters for six cities in China were analyzed by employing software TRNSYS. The surface azimuth had greater effect on solar radiation collection in high latitude regions. For deviation of the surface slope angle within ±20° around the optimized angle, the variation of the total annual collecting solar radiation was less than 5%. However, with deviation of 70° to 90°, the variation was up to 20%. The effects of water cycle mode, reverse slope placement of solar collector, and water tank installation height on system efficiency were experimentally studied. The thermal efficiencies of solar water heater with single row horizontal arrangement all-glass evacuated tubular collector were higher than those with vertical arrangement at the fixed surface slope angle of 90°. Compared with solar water heaters with flat-plate collector under natural circulation, the system thermal efficiency was raised up to 63% under forced circulation. For collector at reverse slope placement, the temperature-based water stratification in water tank deteriorated, and thus the thermal efficiency became low. For improving the system efficiency, an appropriate installation height of the water tank was suggested.

  9. Influence of nanofluids on the efficiency of Flat-Plate Solar Collectors (FPSC)

    Science.gov (United States)

    Nejad, Marjan B.; Mohammed, H. A.; Sadeghi, O.; Zubeer, Swar A.

    2017-11-01

    A numerical investigation is performed using finite volume method to study the laminar heat transfer in a three-dimensional flat-plate solar collector using different nanofluids as working fluids. Three nanofluids with different types of nanoparticles (Ag, MWCNT and Al2O3 dispersed in water) with 1-2 wt% volume fractions are analyzed. A constant heat flux, equivalent to solar radiation absorbed by the collector, is applied at the top surface of the absorber plate. In this study, several parameters including boundary conditions (different volume flow rates, different fluid inlet temperatures and different solar irradiance at Skudai, Malaysia), different types of nanoparticles, and different solar collector tilt angles are investigated to identify their effects on the heat transfer performance of FPSC. The numerical results reveal that the three types of nanofluid enhance the thermal performance of solar collector compared to pure water and FPSC with Ag nanofluid has the best thermal performance enhancement. For all the cases, the collector efficiency increased with the increase of volume flow rate while fluid outlet temperature decreased. It is found that FPSC with tilt angle of 10° and fluid inlet temperature of 301.15 K has the best thermal performance.

  10. Influence of nanofluids on the efficiency of Flat-Plate Solar Collectors (FPSC

    Directory of Open Access Journals (Sweden)

    Nejad Marjan B.

    2017-01-01

    Full Text Available A numerical investigation is performed using finite volume method to study the laminar heat transfer in a three-dimensional flat-plate solar collector using different nanofluids as working fluids. Three nanofluids with different types of nanoparticles (Ag, MWCNT and Al2O3 dispersed in water with 1–2 wt% volume fractions are analyzed. A constant heat flux, equivalent to solar radiation absorbed by the collector, is applied at the top surface of the absorber plate. In this study, several parameters including boundary conditions (different volume flow rates, different fluid inlet temperatures and different solar irradiance at Skudai, Malaysia, different types of nanoparticles, and different solar collector tilt angles are investigated to identify their effects on the heat transfer performance of FPSC. The numerical results reveal that the three types of nanofluid enhance the thermal performance of solar collector compared to pure water and FPSC with Ag nanofluid has the best thermal performance enhancement. For all the cases, the collector efficiency increased with the increase of volume flow rate while fluid outlet temperature decreased. It is found that FPSC with tilt angle of 10° and fluid inlet temperature of 301.15 K has the best thermal performance.

  11. Field Experiments of PV-Thermal Collectors for Residential Application in Bangkok

    Directory of Open Access Journals (Sweden)

    Atsushi Akisawa

    2012-04-01

    Full Text Available This study presents experimental results on Photovoltaic-thermal (PVT solar systems, the commercial photovoltaic (PV panels used as solar absorbers in PVT collectors, which are amorphous and multi-crystalline silicon. Testing was done with outdoor experiments in the climate of Bangkok corresponding to energy consumption behavior of medium size Thai families. The experimental results show that the thermal recovery of amorphous silicon PVT collector is almost the same as that of multi-crystalline silicon PVT collectors while electricity generation of multi crystalline silicon PVT is 1.2 times as much as that of amorphous silicon PVT. The maximum of heat gain from the PVT systems were obtained in March in summer. It was found that PVT collectors of unit area annually produced 1.1 × 103 kWh/m2 .year of heat and 55–83 kWh/m2.year of electricity, respectively. The results show that annual average solar factor of hot water supply is 0.45 for unit collector area. Economical evaluation based on energy costs in Thailand was conducted, which estimated the payback time would be 7 and 14 years for a-Si PVT and mc-Si PV, respectively.

  12. Design and beam transport simulations of a multistage collector for the Israeli EA-FEM

    CERN Document Server

    Tecimer, M; Efimov, S; Gover, A; Sokolowski, J

    2001-01-01

    A four stage asymmetric type depressed collector has been designed for the Israeli mm-wave FEM that is driven by a 1.4 MeV, 1.5 A electron beam. After leaving the interaction section the spent beam has an energy spread of 120 keV and 75 pi mm mrad normalized beam emittance. Simulations of the beam transport system from the undulator exit through the decelerator tube into the collector have been carried out using EGUN and GPT codes. The latter has also been employed to study trajectories of the primary and scattered particles within the collector, optimizing the asymmetrical collector geometry and the electrode potentials at the presence of a deflecting magnetic field. The estimated overall system and collector efficiencies reach 50% and 70%, respectively, with a beam recovery of 99.6%. The design is aimed to attain millisecond long pulse operation and subsequently 1 kW average power. Simulation results are implemented in a mechanical design that leads to a simple, cost efficient assembly eliminating ceramic i...

  13. Metal oxide collectors for storing matter technique applied in secondary ion mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Miśnik, Maciej [Institute of Tele and Radio Technology, ul. Ratuszowa 11, 03-450 Warszawa (Poland); Gdańsk University of Technology (Poland); Konarski, Piotr [Institute of Tele and Radio Technology, ul. Ratuszowa 11, 03-450 Warszawa (Poland); Zawada, Aleksander [Institute of Tele and Radio Technology, ul. Ratuszowa 11, 03-450 Warszawa (Poland); Military University of Technology, Warszawa (Poland)

    2016-03-15

    We present results of the use of metal and metal oxide substrates that serve as collectors in ‘storing matter’, the quantitative technique of secondary ion mass spectrometry (SIMS). This technique allows separating the two base processes of secondary ion formation in SIMS. Namely, the process of ion sputtering is separated from the process of ionisation. The technique allows sputtering of the analysed sample and storing the sputtered material, with sub-monolayer coverage, onto a collector surface. Such deposits can be then analysed by SIMS, and as a result, the so called ‘matrix effects’ are significantly reduced. We perform deposition of the sputtered material onto Ti and Cu substrates and also onto metal oxide substrates as molybdenum, titanium, tin and indium oxides. The process of sputtering is carried within the same vacuum chamber where the SIMS analysis of the collected material is performed. For sputtering and SIMS analysis of the deposited material we use 5 keV Ar{sup +} beam of 500 nA. The presented results are obtained with the use of stationary collectors. Here we present a case study of chromium. The obtained results show that the molybdenum and titanium oxide substrates used as collectors increase useful yield by two orders, with respect to such pure elemental collectors as Cu and Ti. Here we define useful yield as a ratio of the number of detected secondary ions during SIMS analysis and the number of atoms sputtered during the deposition process.

  14. Development of a Direct Methanol Fuel Cell with Lightweight Disc Type Current Collectors

    Directory of Open Access Journals (Sweden)

    Yean-Der Kuan

    2014-05-01

    Full Text Available The direct methanol fuel cell (DMFC adopts methanol solution as a fuel suitable for low power portable applications. A miniature, lightweight, passive air-breathing design is therefore desired. This paper presents a novel planar disc-type DMFC with multiple cells containing a novel developed lightweight current collector at both the anode and cathode sides. The present lightweight current collector adopts FR4 Glass/Epoxy as the substrate with the current collecting areas located at the corresponding membrane electrolyte assembly (MEA areas. The current collecting areas are fabricated by sequentially coating a corrosion resistant layer and electrical conduction layer via the thermal evaporation technique. The anode current collector has carved flow channels for fuel transport and production. The cathode current collector has drilled holes for passive air breathing. In order to ensure feasibility in the present concept a 3-cell prototype DMFC module with lightweight disc type current collectors is designed and constructed. Experiments were conducted to measure the cell performance. The results show that the highest cell power output is 54.88 mW·cm−2 and successfully demonstrate the feasibility of this novel design.

  15. A Dynamic Multinode Model for Component-Oriented Thermal Analysis of Flat-Plate Solar Collectors

    Directory of Open Access Journals (Sweden)

    Christoph N. Reiter

    2015-01-01

    Full Text Available A mathematical model of a flat-plate solar collector was developed on the basis of the physical principles of optics and heat transfer in order to determine collector’s component temperatures as well as collector efficiency. In contrast to many available models, the targeted use of this dynamic model is the detailed, theoretical investigation of the thermal behaviour of newly developed or adjusted collector designs on component level, for example, absorber, casing, or transparent cover. The defined model is based on a multinode network (absorber, fluid, glazing, and backside insulation containing the relevant physical equations to transfer the energy. The heat transfer network covers heat conduction, convection, and radiation. Furthermore, the collector optics is defined for the plane glazing and the absorber surface and also considers interactions between them. The model enables the variation of physical properties considering the geometric parameters and materials. Finally, the model was validated using measurement data and existing efficiency curve models. Both comparisons proved high accuracy of the developed model with deviation of up to 3% in collector efficiency and 1 K in component temperatures.

  16. Adsorption of guanidinium collectors on aluminosilicate minerals - a density functional study.

    Science.gov (United States)

    Nulakani, Naga Venkateswara Rao; Baskar, Prathab; Patra, Abhay Shankar; Subramanian, Venkatesan

    2015-10-07

    In this density functional theory based investigation, we have modelled and studied the adsorption behaviour of guanidinium cations and substituted (phenyl, methoxy phenyl, nitro phenyl and di-nitro phenyl) guanidinium cationic collectors on the basal surfaces of kaolinite and goethite. The adsorption behaviour is assessed in three different media, such as gas, explicit water and pH medium, to understand the affinity of GC collectors to the SiO4 tetrahedral and AlO6 octahedral surfaces of kaolinite. The tetrahedral siloxane surface possesses a larger binding affinity to GC collectors than the octahedral sites due to the presence of surface exposed oxygen atoms that are active in the intermolecular interactions. Furthermore, the inductive electronic effects of substituted guanidinium cations also play a key role in the adsorption mechanism. Highly positive cations result in a stronger electrostatic interaction and preferential adsorption with the kaolinite surfaces than low positive cations. Computed interaction energies and electron densities at the bond critical points suggest that the adsorption of guanidinium cations on the surfaces of kaolinite and goethite is due to the formation of intra/inter hydrogen bonding networks. Also, the electrostatic interaction favours the high adsorption ability of GC collectors in the pH medium than gas phase and water medium. The structures and energies of GC collectors pave an intuitive view for future experimental studies on mineral flotation.

  17. Annual Optimum Tilt Angle Prediction of Solar Collector using PSO Estimator

    Science.gov (United States)

    Dixit, T. V.; Yadav, Anamika; pre="Senior Member ">IEEE,

    2017-08-01

    The amount of solar flux falls on solar collector depends on tilt angle and orientation of collector from the surface. By efficiently regulating the tilt and orientation of solar collector unnecessary loss in potential power can be minimized. In general, for north hemisphere, south facing of the collector is considered as optimum orientation. There are several metrological and geographical factors which affect the optimum tilt angle. In this paper, the PSO estimator has been proposed in order to find optimum tilt angle on annual basis. The results of PSO estimators are compared with ANN estimator and satellite (RETScreen software) data. To evaluate the performance of proposed model MBE, RMSE, Error range, percentage annual error as well as direct method of statistical study have been carried out. During annual tilt angle prediction the annual percentage errors of proposed method and RETScreensoftware data are 0.03% and 7.03% respectively with respect to ANN results. Finally, the average percentage error indicates that the proposed estimator gives better prediction as compared to satellite based results for collecting maximum solar flux at surface of solar collector.

  18. Signs of musculoskeletal disorders in bus drivers and fare collectors

    Directory of Open Access Journals (Sweden)

    Malú de Oliveira Freire

    2007-09-01

    Full Text Available To describe the signs of musculoskeletal disorders (SMD in drivers and fare ollectors and to investigate their association with hours worked per day, nutritional status and level of physical activity (PA. A cross-sectional study undertaken with 40 bus drivers and 39 fare collectors working intercity routes. The “Nordic Musculoskeletal Questionnaire” was used to identify SMD. The working day was defi ned according to median values ( ABSTRACT O objetivo deste estudo foi descrever os sintomas de distúrbios osteomusculares (SDO em motoristas e cobradores de ônibus e investigar sua associação com jornada de trabalho, estado nutricional e nível de atividade física. Estudo transversal realizado com 40 motoristas e 39 cobradores de ônibus de viagens intermunicipais. Os SDO foram verificados, utilizando-se o Questionário Nórdico de Sintomas Osteomusculares. A jornada de trabalho foi categorizada a partir dos valores da mediana (< 8 horas e ≥ 8 horas. O índice de massa corporal (IMC foi usado para verificar o estado nutricional. O nível de atividade física foi avaliado, usando-se o Questionário Internacional de Atividade Física (versão curta. As associações foram verifi cadas por teste qui-quadrado. A freqüência de dor em alguma região do corpo (últimos 12 meses foi de 70,0% e 76,9% para motoristas e cobradores respectivamente; 30,0% dos motoristas e 33,3% dos cobradores referiram dor nos últimos 7 dias; 26,6% e 33,3% dos motoristas e cobradores, respectivamente, tiveram que evitar o trabalho devido às dores. As maiores prevalências (últimos 12 meses foram observadas nas seguintes regiões anatômicas: ombros (32,5%, para motoristas e; lombar (48,7%, para cobradores. Houve diferença significativa (p = 0,029 entre motoristas e cobradores quanto ao relato de dor na região “lombar”. A prevalência de sobrepeso foi maior nos motoristas (72,0% do que nos cobradores (33,3%, as diferenças foram signifi cativas (p = 0

  19. MERCURY CONTROL WITH THE ADVANCED HYBRID PARTICULATE COLLECTOR

    Energy Technology Data Exchange (ETDEWEB)

    Ye Zhuang; Stanley J. Miller; Steven A. Benson; Michelle R. Olderbak

    2003-08-01

    This project was awarded under U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) Program Solicitation DE-PS26-00NT40769 and specifically addresses Technical Topical Area 4-Testing Novel and Less Mature Control Technologies on Actual Flue Gas at the Pilot Scale. The project team includes the Energy & Environmental Research Center (EERC) as the main contractor; W.L. Gore & Associates, Inc., as a technical and financial partner; and the Big Stone Plant operated by Otter Tail Power Company, host for the field-testing portion of the research. Since 1995, DOE has supported development of a new concept in particulate control called the advanced hybrid particulate collector (AHPC). The AHPC has been licensed to W.L. Gore & Associates, Inc., and is now marketed as the ''Advanced Hybrid''{trademark} filter by Gore. The AHPC combines the best features of electrostatic precipitators (ESPs) and baghouses in a unique configuration, providing major synergism between the two collection methods, both in the particulate collection step and in the transfer of dust to the hopper. The AHPC provides ultra-high collection efficiency, overcoming the problem of excessive fine-particle emissions with conventional ESPs, and it solves the problem of reentrainment and re-collection of dust in conventional baghouses. The AHPC appears to have unique advantages for mercury control over baghouses or ESPs as an excellent gas-solid contactor. The objective of the three-task project is to demonstrate 90% total mercury control in the AHPC at a lower cost than current mercury control estimates. The approach includes bench-scale batch testing that ties the new work to previous results and links results with larger-scale pilot testing with real flue gas on a coal-fired combustion system, pilot-scale testing on a coal-fired combustion system with both a pulse-jet baghouse and an AHPC to prove or disprove the research hypotheses, and field demonstration pilot

  20. Heat Lump in Different Pavement Layer Using Ethylene Glycol as A Solar Heat Collector

    Directory of Open Access Journals (Sweden)

    Talib Siti Hidayah Abu

    2017-01-01

    Full Text Available Due to the hot weather in Malaysia, several studies being carried out regarding solar energy harvesting and use as a noble renewable energy. Therefore, researchers start developing various methods to utilize sun’s heat as a renewable source of energy. Solar energy has been always concern researchers to develop most effective, durable and cheap methods and materials to be used as solar energy collectors in road pavements. Therefore, this study was conducted to determine the maximum heat area using ethylene glycol. The study was involved the field monitoring of the six samples of asphalt slab with stainless steel pipe with ethylene glycol and empty pipe act as the controlled sample. The pipe was arranged in three different depths of 50mm, 100mm and 150mm and keeping controlled the pipe diameter and the size of slab of 20mm and 300mm x 300mm respectively. These results show that the maximum heat extraction by the ethylene glycol was at a depth 150mm which was 51.2°C. The average percentage increments of the pipe with ethylene glycol for three days for pipe depth 50mm was 71%, while for pipe at depth 100mm and 150mm were 78% and 62% respectively. The ethylene glycol effect was more noticeable compare to the pipe without ethylene glycol and can store more heat. For the strength of pipe, the highest maximum load bearing capacity that can be supported by the stainless steel pipe was at depth 50mm and the second highest was at a depth 100mm while the third highest was at depth 150mm. So, the suitable depth to install the pipe with the consideration of both cases which was maximum heat gain and the maximum load that can be supported was at depth 50mm.

  1. Spatial patterns of atmospheric deposition of nitrogen and sulfur using ion-exchange resin collectors in Rocky Mountain National Park, USA

    Science.gov (United States)

    Clow, David W.; Roop, Heidi; Nanus, Leora; Fenn, Mark; Sexstone, Graham A.

    2015-01-01

    Lakes and streams in Class 1 wilderness areas in the western United States (U.S.) are at risk from atmospheric deposition of nitrogen (N) and sulfur (S), and protection of these resources is mandated under the Federal Clean Air Act and amendments. Assessment of critical loads, which are the maximum exposure to pollution an area can receive without adverse effects on sensitive ecosystems, requires accurate deposition estimates. However, deposition is difficult and expensive to measure in high-elevation wilderness, and spatial patterns in N and S deposition in these areas remain poorly quantified. In this study, ion-exchange resin (IER) collectors were used to measure dissolved inorganic N (DIN) and S deposition during June 2006–September 2007 at approximately 20 alpine/subalpine sites spanning the Continental Divide in Rocky Mountain National Park. Results indicated good agreement between deposition estimated from IER collectors and commonly used wet + dry methods during summer, but poor agreement during winter. Snowpack sampling was found to be a more accurate way of quantifying DIN and S deposition during winter. Summer DIN deposition was significantly greater on the east side of the park than on the west side (25–50%; p ≤ 0.03), consistent with transport of pollutants to the park from urban and agricultural areas to the east. Sources of atmospheric nitrate (NO3−) were examined using N isotopes. The average δ15N of NO3− from IER collectors was 3.5‰ higher during winter than during summer (p combustion and vehicular sources of atmospheric NO3−. There were no significant differences in δ15N of NO3− between east and west sides of the park during summer or winter (p = 0.83), indicating that the two areas may have similar sources of atmospheric NO3−. Results from this study indicate that a combination of IER collectors and snowpack sampling can be used to characterize spatial variability in DIN and S deposition in high-elevation wilderness

  2. A Large-Radius High-Mass-Resolution Multiple-Collector Isotope Ratio Mass Spectrometer for Analysis of Rare Isotopologues of CH4 and Other Gases

    Science.gov (United States)

    Young, E. D.; Rumble, D.; Freedman, P.; Mills, M.

    2016-12-01

    We describe a unique and novel isotope ratio mass spectrometer (IRMS), the Panorama, developed explicitly for high-mass-resolution analysis of isotopologue ratios of gas samples. The double-focussing instrument routinely operates at a mass resolving power of 40,000 with a maximum useful MRP of 80,000. The instrument achieves this exceptional MRP for a multi-collector using a Matsuda ion optical design with an ESA radius of 1018 mm and a magnetic sector radius of 800 mm. Collectors comprise 9 Faraday cups and a single channel of ion counting each with continuously variable collector slits. The continously variable collector slits are key for making meausrements of rare doubly-substituted species free of corrections that would otherwise be necessitated by intefereing ion beams. First results demonstrate both accuracy and precision for singly and doubly-substituted molecular species. Our first applications have focussed on resolving the mass-18 rare isotopologues of methane, 12CH2D2 and 13CH3D. By measuring a wide variety of natural methane sources, we find that the ability to separate these two species allows one to substantiate temperatures of methane bond formation where temperatures from the two species are concordant, representing thermodynamic equilibrium. Conversely, where the species are in disequilibrium, the data provide evidence for the reaction pathways for methane formation or subsequent processing, including mixing with other reservoirs. Concordant temperatures are sometimes inconsistent with previous estimates from indirect methods. These sometimes surprising results are fortified by the concordancy of two doubly-substituted isotopologues. Similarly, there are instances in which the temperatures derived from the relative concentrations of 13CH3D seem plausible, yet substantial kinetically-induced deficits in 12CH2D2show that these temperatures are in fact suspect. The ability to measure more than one doubly-substituted istopologue in the same gas, now

  3. Towards standardization of in-site parabolic trough collector testing in solar thermal power plants

    Science.gov (United States)

    Sallaberry, Fabienne; Valenzuela, Loreto; de Jalón, Alberto García; Leon, Javier; Bernad, Ignacio David

    2016-05-01

    This paper presents a summary of the testing procedure and a validation of the methodology of parabolic trough collector in solar thermal power plants. The applied testing methodology is the one proposed within the Spanish standardization sub-committee AEN/CTN 206/SC117 working group WG2 related to the components for solar thermal power plants. This methodology is also proposed within the international committee IEC TC 117 (Standard draft IEC 62862-3-2 Ed. 1.0). This study is done at Plataforma Solar de Almería (PSA) in Almeria within the European project STAGE-STE. This paper presents the results of the optical and thermal efficiency of a large-size parabolic trough collector. The obtained values are similar to the previous analysis on this collector by PSA. The results of the tracking system have a good accuracy compared to the acceptance angle of the concentrator.

  4. Thermal Performance Analysis of Solar Collectors Installed for Combisystem in the Apartment Building

    Science.gov (United States)

    Žandeckis, A.; Timma, L.; Blumberga, D.; Rochas, C.; Rošā, M.

    2012-01-01

    The paper focuses on the application of wood pellet and solar combisystem for space heating and hot water preparation at apartment buildings under the climate of Northern Europe. A pilot project has been implemented in the city of Sigulda (N 57° 09.410 E 024° 52.194), Latvia. The system was designed and optimised using TRNSYS - a dynamic simulation tool. The pilot project was continuously monitored. To the analysis the heat transfer fluid flow rate and the influence of the inlet temperature on the performance of solar collectors were subjected. The thermal performance of a solar collector loop was studied using a direct method. A multiple regression analysis was carried out using STATGRAPHICS Centurion 16.1.15 with the aim to identify the operational and weather parameters of the system which cause the strongest influence on the collector's performance. The parameters to be used for the system's optimisation have been evaluated.

  5. PERFORMANCE CHARACTERISTICS OF PARABOLIC SOLAR COLLECTOR WATER HEATER SYSTEM FITTED WITH NAIL TWISTED TAPES ABSORBER

    Directory of Open Access Journals (Sweden)

    K. SYED JAFAR

    2017-03-01

    Full Text Available In this paper, the experimental heat transfer, friction loss and thermal performance data for water flowing through the absorber tube fitted with two different twisted tape configurations in parabolic trough collector (PTC are presented. In the present work, a relative experimental study is carried out to investigate the performance of a PTC influenced by heat transfer through fluidabsorber wall mixing mechanism. The major findings of this experiment show that heat transport enhancement in the nail twisted tape collector perform significantly better than plain twisted tapes and also show that the smallest twisted tape ratio enhances the system performance remarkably maximizing the collector efficiency. The results suggest that the twisted tape and nail twisted tape would be a better option for high thermal energy collection in laminar region of the PTC system.

  6. Investigation and Measurement of Copper Nanofluid Impact on Thermal Efficiency of Solar Collectors

    Directory of Open Access Journals (Sweden)

    Assadi Morteza Khalaji

    2014-07-01

    Full Text Available This study compared the impacts of using copper nanofliud to enhance the efficiency of flat solar collectors with closed loop and under forced convection heat transfer circumstances to traditional work fluids. Various concentrations of nanoparticles in water and water/glycol, from 250ppm to 3000ppm, were examined for volume fraction impact. Results indicate that the laboratory tests were different from those under real conditions because of the high concentration of nanoparticles used in laboratory tests; however, by using nanofluid (even with low concentrations around 0.3% solar collector efficiency improved (3.2%.Results have also shown that the use of copper nanofluid in ethylene glycol as the base fluid causes a significant reduction in collector efficiency, due to the increase in viscosity. However, using higher flow rates caused the heat transfer rate to rise because of increased turbulence.

  7. Compendium of information on identification and testing of materials for plastic solar thermal collectors

    Energy Technology Data Exchange (ETDEWEB)

    McGinniss, V.D.; Sliemers, F.A.; Landstrom, D.K.; Talbert, S.G.

    1980-07-31

    This report is intended to organize and summarize prior and current literature concerning the weathering, aging, durability, degradation, and testing methodologies as applied to materials for plastic solar thermal collectors. Topics covered include (1) rate of aging of polymeric materials; (2) environmental factors affecting performance; (3) evaluation and prediction of service life; (4) measurement of physical and chemical properties; (5) discussion of evaluation techniques and specific instrumentation; (6) degradation reactions and mechanisms; (7) weathering of specific polymeric materials; and (8) exposure testing methodology. Major emphasis has been placed on defining the current state of the art in plastics degradation and on identifying information that can be utilized in applying appropriate and effective aging tests for use in projecting service life of plastic solar thermal collectors. This information will also be of value where polymeric components are utilized in the construction of conventional solar collectors or any application where plastic degradation and weathering are prime factors in material selection.

  8. Performance study of unglazed cylindrical solar collector for adsorption refrigeration system

    Science.gov (United States)

    Mahesh, A.; Kaushik, S. C.; Kumaraguru, A. K.

    2013-12-01

    In the present communication, the unglazed cylindrical solar adsorber module is suggested for refrigeration and theoretical models for the heat and mass transfer in the cylindrical adsorber with heat balance equations in the collector components have been developed. It has been found that, both the SCP and COPsolar raises with increasing the evaporation temperature and drop off with the increase of the condensation temperature. The COPsolar increased from 0.15 to 0.52 with the increase of the total solar energy absorbed by the collector while the COPcycle varied in the range of 0.57-0.73. The efficiency of unglazed solar collector varied from 36 to 44 %. The cost of current unglazed adsorption refrigeration system is compared with the glazed system, and it is 33 to 50 % less than the cost of glazed system.

  9. Thin Flexible Lithium Ion Battery Featuring Graphite Paper Based Current Collectors with Enhanced Conductivity

    CERN Document Server

    Qu, Hang; Tang, Yufeng; Semenikihin, Oleg; Skorobogatiy, Maksim

    2015-01-01

    A flexible, light weight and high conductivity current collector is the key element that enables fabrication of high performance flexible lithium ion battery. Here we report a thin, light weight and flexible lithium ion battery that uses graphite paper enhanced with a nano-sized metallic layers as the current collector, LiFePO4 and Li4Ti5O12 as the cathode and anode materials, and PE membrane soaked in LiPF6 as a separator. Using thin and flexible graphite paper as a substrate for the current collector instead of a rigid and heavy metal foil enables us to demonstrate a very thin Lithium-Ion Battery into ultra-thin (total thickness including encapsulation layers of less than 250 {\\mu}m) that is also light weight and highly flexible.

  10. Automated solar collector installation design including ability to define heterogeneous design preferences

    Science.gov (United States)

    Wayne, Gary; Frumkin, Alexander; Zaydman, Michael; Lehman, Scott; Brenner, Jules

    2013-01-08

    Embodiments may include systems and methods to create and edit a representation of a worksite, to create various data objects, to classify such objects as various types of pre-defined "features" with attendant properties and layout constraints. As part of or in addition to classification, an embodiment may include systems and methods to create, associate, and edit intrinsic and extrinsic properties to these objects. A design engine may apply of design rules to the features described above to generate one or more solar collectors installation design alternatives, including generation of on-screen and/or paper representations of the physical layout or arrangement of the one or more design alternatives. Embodiments may also include definition of one or more design apertures, each of which may correspond to boundaries in which solar collector layouts should comply with distinct sets of user-defined design preferences. Distinct apertures may provide heterogeneous regions of collector layout according to the user-defined design preferences.

  11. Dynamic thermal performance analysis of two solar air collectors with and without porous media

    Directory of Open Access Journals (Sweden)

    Abed Qahtan A.

    2016-01-01

    Full Text Available The paper presents the thermal performance comparison between two types of solar air collectors, with and without porous absorber material. In order to simulate the transient processes which occur in the collectors two mathematical models were developed. Each model consists of a set of time dependent equations which describe the energy balance for the main components of the collector considering time-dependent thermo-physical properties and heat transfer coefficients. The theoretical models were validated by experimental data obtained from measurements performed in different meteorological conditions characteristic to the city of Bucharest – Romania (latitude 44°26′ N, longitude 26°6′ E. Good agreement between the simulation results and experimental data was achieved.

  12. Copper current collectors reduce long-term fouling of air cathodes in microbial fuel cells

    KAUST Repository

    Myung, Jaewook

    2018-02-05

    Long-term operation of wastewater-fed, microbial fuel cells (MFCs) with cathodes made of activated carbon and stainless steel (SS) current collectors can result in decreased performance due to cathode fouling. Copper has good antimicrobial properties, and it is more electrically conductive than SS. To demonstrate that a copper current collector could produce a more fouling resistant cathode, MFCs with air cathodes using either SS or copper current collectors were operated using domestic wastewater for 27 weeks. The reduction in biofouling over time was shown by less biofilm formation on the copper cathode surface compared to SS cathodes, due to the antimicrobial properties of copper. Maximum power densities from 17–27 weeks were 440 ± 38 mW/m2 using copper and 370 ± 21 mW/m2 using SS cathodes. The main difference in the microbial community was a nitrifying community on the SS cathodes, which was not present on the copper cathodes.

  13. Effects of nanometric hydrophobic layer on performances of solar photovoltaic collectors

    Directory of Open Access Journals (Sweden)

    Andrei BUTUZA

    2014-11-01

    Full Text Available The study refers to the experimental investigation of solar photovoltaic collectors' behaviour when the glazed surface is treated with a nanometric layer of hydrophobic solution. The experiment was carried out on two photovoltaic collectors, of which one was considered as reference and the other one was coated with a commercial hydrophobic solution. It was studied the evolution of the following electrical parameters: current, voltage, power, efficiency and daily energy production. The voltage was almost unaffected, but for all the others parameters, important drop were recorded. The preliminary conclusion of the study is that the use of hydrophobic solutions, for the treatment of glazed surfaces of solar collectors is not recommended. This hypothesis needs supplementary investigations and measurements in the context of reduced available information concerning the optical properties of hydrophobic solutions.

  14. Electrochemistry of thin-plate lead-carbon batteries employing alternative current collectors

    Science.gov (United States)

    Lannelongue, Jérémy; Cugnet, Mikael; Guillet, Nicolas; Kirchev, Angel

    2017-06-01

    The article discusses the electrochemistry of lead-carbon battery cells based on thin-plate electrodes with alternative current collectors. The latter are comprised of lead-electroplated graphite foil and expanded titanium mesh coated with SnO2 replacing the conventional negative and positive grids. The results from charge/discharge tests, cycling voltammetry and impedance spectroscopy measurements show that the negative electrodes store energy via three types of electrochemical processes: electrostatic storage, reversible hydrogen storage and precipitation/dissolution of lead and lead sulfate. When the activated carbon is the predominant component of the negative active material the preferred energy storage mechanism is the reversible hydrogen storage. The use of titanium as alternative current collector allows to increase the active material to current collector ratio to 5: 1, retaining a high power performance and increasing the battery lifetime beyond 3000 equivalent cycles in partial state of charge cycling applications.

  15. Microelectrode generator-collector systems for electrolytic titration: theoretical and practical considerations.

    Science.gov (United States)

    Bell, Christopher G; Seelanan, Parinya; O'Hare, Danny

    2017-10-23

    Electochemical generator-collector systems, where one electrode is used to generate a reagent, have a potentially large field of application in sensing and measurement. We present a new theoretical description for coplanar microelectrode disc-disc systems where the collector is passive (such as a potentiometric sensor) and the generator is operating at constant flux. This solution is then used to develop a leading order solution for such a system where the reagent reacts reversibly in solution, such as in acid-base titration, where a hydrogen ion flux is generated by electrolysis of water. The principal novel result of the theory is that such devices are constrained by a maximum reagent flux. The hydrogen ion concentration at the collector will only reflect the buffer capacity of the bulk solution if this constraint is met. Both mathematical solutions are evaluated with several microfabricated devices and reasonable agreement with theory is demonstrated.

  16. The Theoretical Analysis of Mass and Energy Flow Through Solar Collector – Chimney System

    Directory of Open Access Journals (Sweden)

    Lipnicki Zygmunt

    2017-03-01

    Full Text Available The goal of the paper was to simplify the designing process for mass and energy flow through solar collector - chimney system. Theoretical analysis allowed to get involved system of three nonlinear analytical equations in dimensionless forms that have been saved. Dimensionless numbers for the problem are well known in the literature on fluid mechanics and thermodynamics: Reynolds, Grashof, Galileo, Biot and Prandtl. In the analyzed equations are also dimensionless geometric parameters expressing the ratios of basic geometrical dimensions of the collector system-chimney: the radius disc collector to the thickness gap, the height and radius of the chimney. In the system of equations, the Reynolds number is treated as the determined number, which is a novelty of the method used.

  17. A new Laplace transformation method for dynamic testing of solar collectors

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Perers, Bengt; Fan, Jianhua

    2015-01-01

    A new dynamic method for solar collector testing is developed. It is characterized by using the Laplace transformation technique to solve the differential governing equation. The new method was inspired by the so called New Dynamic Method (NDM) (Amer E. et al (1999) [1]) but totally different....... By integration of the Laplace transformation technique with the Quasi Dynamic Test (QDT) model (Fischer S. et al (2004) [2]), the Laplace – QDT (L-QDT) model is derived. Two experimental methods are then introduced. One is the shielding method which needs to shield and un-shield solar collector continuously...... and the natural experimental method. The identified collector parameters are then compared and analyzed with those obtained by the steady state test method and the QDT test method. The results comparison shows that the L-QDT method and the natural experimental method are also valid. It can be concluded...

  18. Side by side tests of two SDHW systems with solar collectors with and without antireflection treatment

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Han, Jiangong; Perers, Bengt

    2015-01-01

    Two low flow SDHW systems based on mantle tanks are tested side by side in a laboratory test facility for solar heating systems under the same weather and operation conditions. The systems are identical with the exception that one system is equipped with a solar collector with antireflection...... agreement between measured and calculated thermal performances for both systems. The extra thermal performance of the system with the solar collector with the anti reflection treated glass cover is a strong function of the solar fraction. In sunny periods with high solar fractions the percentage extra...... treated glass while the other system has a collector with a normal glass. Measurements of the thermal performance of the two systems have been carried out for a long measuring period. The thermal performances of the systems have also been calculated with a detailed simulation model. There is a good...

  19. Using Image Pro Plus Software to Develop Particle Mapping on Genesis Solar Wind Collector Surfaces

    Science.gov (United States)

    Rodriquez, Melissa C.; Allton, J. H.; Burkett, P. J.

    2012-01-01

    The continued success of the Genesis mission science team in analyzing solar wind collector array samples is partially based on close collaboration of the JSC curation team with science team members who develop cleaning techniques and those who assess elemental cleanliness at the levels of detection. The goal of this collaboration is to develop a reservoir of solar wind collectors of known cleanliness to be available to investigators. The heart and driving force behind this effort is Genesis mission PI Don Burnett. While JSC contributes characterization, safe clean storage, and benign collector cleaning with ultrapure water (UPW) and UV ozone, Burnett has coordinated more exotic and rigorous cleaning which is contributed by science team members. He also coordinates cleanliness assessment requiring expertise and instruments not available in curation, such as XPS, TRXRF [1,2] and synchrotron TRXRF. JSC participates by optically documenting the particle distributions as cleaning steps progress. Thus, optical document supplements SEM imaging and analysis, and elemental assessment by TRXRF.

  20. PERFORMANCE ANALYSIS OF FORCED CONVECTION EVACUATED TUBE SOLAR COLLECTOR USED FOR GRAPE DRYER

    Directory of Open Access Journals (Sweden)

    A. B. UBALE

    2017-01-01

    Full Text Available In the present experimental study an evacuated tube solar collector is designed, fabricated and its performance is tested in the force convection mode of heat transfer. The solar collector is designed for the grape dryer of capacity 10kg per batch. Experiments are carried out in the month of April to produce raisins for Thomson Seedless grapes, with initial moisture content of 77 (kg per kg on wet basis% to final moisture content of 19 (kg per kg on wet basis% in 36 hours. Raisins produced from this system are tested for varies parameters to check its quality and found satisfactory results. The average collector efficiency is found to be 23.4%.