WorldWideScience

Sample records for equivalent exposure inee

  1. Indoor nature exposure (INE): a health-promotion framework.

    Science.gov (United States)

    Mcsweeney, J; Rainham, D; Johnson, S A; Sherry, S B; Singleton, J

    2015-03-01

    Engaging in outdoor nature-based spaces has significant positive physiological and psychological health benefits. Although the integration of nature into indoor spaces is rarely considered a health-promoting tool, it may be an effective method for increasing nature engagement in a largely urbanized world. This paper presents an overview of indoor nature exposure (INE) by summarizing the current evidence of INE through the use of a scoping methodology. Results show that INE can be a health-promoting tool through the interaction of nature-based stimuli and individual characteristics (e.g. gender, age). Moreover, the results of the current literature need to be interpreted with consideration to methodological issues, such as the lack of participant characteristics, the issue of exposure realism and little qualitative data to highlight individual experiences. The scoping review process allowed for the summation of results and for a framework to be created in order to better understand how INE is facilitated. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. A practical exposure-equivalent metric for instrumentation noise in x-ray imaging systems

    International Nuclear Information System (INIS)

    Yadava, G K; Kuhls-Gilcrist, A T; Rudin, S; Patel, V K; Hoffmann, K R; Bednarek, D R

    2008-01-01

    The performance of high-sensitivity x-ray imagers may be limited by additive instrumentation noise rather than by quantum noise when operated at the low exposure rates used in fluoroscopic procedures. The equipment-invasive instrumentation noise measures (in terms of electrons) are generally difficult to make and are potentially not as helpful in clinical practice as would be a direct radiological representation of such noise that may be determined in the field. In this work, we define a clinically relevant representation for instrumentation noise in terms of noise-equivalent detector entrance exposure, termed the instrumentation noise-equivalent exposure (INEE), which can be determined through experimental measurements of noise-variance or signal-to-noise ratio (SNR). The INEE was measured for various detectors, thus demonstrating its usefulness in terms of providing information about the effective operating range of the various detectors. A simulation study is presented to demonstrate the robustness of this metric against post-processing, and its dependence on inherent detector blur. These studies suggest that the INEE may be a practical gauge to determine and compare the range of quantum-limited performance for clinical x-ray detectors of different design, with the implication that detector performance at exposures below the INEE will be instrumentation-noise limited rather than quantum-noise limited

  3. INES in Spain

    International Nuclear Information System (INIS)

    Zarzuela, J.

    1997-01-01

    The presentation discusses the INES activities in Spain addressing the following issues: applicability; rating procedure; public information; activities in 1997; events above level 0 (October 1996 - September 1997); difficulties

  4. The INES scale

    International Nuclear Information System (INIS)

    2014-01-01

    This document presents the International Nuclear Event Scale (INES) which has been created to classify nuclear and radiological events in terms of severity. This scale comprises eight levels from 0 to 7, from a slight but noticeable shift with respect to nominal operation to a major accident. Criteria used for incident and accident classification are indicated; they are based on consequences outside the site, consequences within the site, degradation of in-depth defence. The benefit and weaknesses of this scale are briefly indicated. The major concerned actors are the IAEA, the NEA and the ASN. Some key figures are given (number of declared events and incidents), and a ranking of the main nuclear events is proposed with a brief description of the event: Chernobyl, Fukushima, Kyshtym, Three Mile Island, Sellafield, Tokaimura, Saint-Laurent-des-Eaux. Countries which have adopted INES are indicated, as well as the number of incidents reports in France to the ASN

  5. Dose equivalent distribution during occupational exposure in oncology

    International Nuclear Information System (INIS)

    Marco H, J.

    1996-01-01

    In this work are presented the results of the radiological surveillance of occupationally exposed workers at the National Institute of Oncology and Radiology during 26 years. The incidence of the equivalent dose in the personal working with radiant sources and radioactive substances in areas of x rays diagnostic, teletherapy, brachytherapy, nuclear medicine and biomedical research was showed. The employed dosimetric system makes use of ORWO RD3/RD4 monitoring film with copper and lead filters inside a plastic cassette manufactured in Cuba. The experimental method is supported by the optical densitometric analysis of films together with a set of standard film calibrated in standard X and gamma photon beams by means of a secondary standard dosimeter, type NPL. Statistics show that except those workings with radium-226, manual brachytherapy or Mo-99/Tc-99 generator elution, the equivalent dose distribution in our workers has been kept in regions well down the annual permissible limit. (authors). 6 refs., 3 tabs

  6. Risk equivalent of exposure versus dose of radiation

    International Nuclear Information System (INIS)

    Bond, V.P.

    1986-01-01

    This report describes a risk analysis study of low-dose irradiation and the resulting biological effects on a cell. The author describes fundamental differences between the effects of high-level exposure (HLE) and low-level exposure (LLE). He stresses that the concept of absorbed dose to an organ is not a dose but a level of effect produced by a particular number of particles. He discusses the confusion between a linear-proportional representation of dose limits and a threshold-curvilinear representation, suggesting that a LLE is a composite of both systems

  7. Risk equivalent of exposure versus dose of radiation

    International Nuclear Information System (INIS)

    Bond, V.P.

    1986-01-01

    Radiation is perhaps unique among all agents of interest in the Health Sciences in that it alone is both a therapeutic agent for the control of cancer and an essentially ubiquitous environmental agent with a potential for increasing the cancer rate in human populations. Therapy of tumors is accomplished with the high-level exposure (HLE) to radiation in order to effect control or a cure. Thus, it conforms to the concepts and approaches of pharmacology, toxicology, and therapeutic medicine. Only one function, that which relates the object-oriented and nonstochastic independent variable organ dose to its effect on a cancer or an organ, is needed to estimate the probability, P 2 , of a quantal response. Only P 2 is needed because P 1 , that the cancer slated for such treatment will receive some amount of the agent and be affected to some degree, is effectively unity. The health problem involving low-level exposure (LLE) to radiation, in contrast, is not at all analogous to those of pharmacology, toxicology, and medicine. Rather, it presents a public health problem in that it is a health population, albeit of cells, that is exposed in a radiation field composed of moving radiation particles with some attendant low-order carcinogenic or mutagenic risk. Thus, the concepts, quantities, and terminology applied to low-level radiation must be modified from their present orientation toward pharmacology, toxicology, medicine, and dose to conform to those of public health and accident statistics, in which both P 1 and P 2 for the exposed cells must be estimated

  8. Antipsychotic dose equivalents and dose-years: a standardized method for comparing exposure to different drugs.

    Science.gov (United States)

    Andreasen, Nancy C; Pressler, Marcus; Nopoulos, Peg; Miller, Del; Ho, Beng-Choon

    2010-02-01

    A standardized quantitative method for comparing dosages of different drugs is a useful tool for designing clinical trials and for examining the effects of long-term medication side effects such as tardive dyskinesia. Such a method requires establishing dose equivalents. An expert consensus group has published charts of equivalent doses for various antipsychotic medications for first- and second-generation medications. These charts were used in this study. Regression was used to compare each drug in the experts' charts to chlorpromazine and haloperidol and to create formulas for each relationship. The formulas were solved for chlorpromazine 100 mg and haloperidol 2 mg to derive new chlorpromazine and haloperidol equivalents. The formulas were incorporated into our definition of dose-years such that 100 mg/day of chlorpromazine equivalent or 2 mg/day of haloperidol equivalent taken for 1 year is equal to one dose-year. All comparisons to chlorpromazine and haloperidol were highly linear with R(2) values greater than .9. A power transformation further improved linearity. By deriving a unique formula that converts doses to chlorpromazine or haloperidol equivalents, we can compare otherwise dissimilar drugs. These equivalents can be multiplied by the time an individual has been on a given dose to derive a cumulative value measured in dose-years in the form of (chlorpromazine equivalent in mg) x (time on dose measured in years). After each dose has been converted to dose-years, the results can be summed to provide a cumulative quantitative measure of lifetime exposure. Copyright 2010 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  9. Temporary threshold shifts from exposures to equal equivalent continuous A-weighted sound pressure level

    DEFF Research Database (Denmark)

    Ordoñez, Rodrigo Pizarro; Hammershøi, Dorte

    2014-01-01

    the assumptions made using the A-weighting curve for the assessment of hearing damage. By modifying exposure ratings to compensate for the build-up of energy at mid and high-frequencies (above 1 kHz) due to the presence of the listener in the sound field and for the levels below an effect threshold that does...... not induce changes in hearing (equivalent quiet levels), ratings of the sound exposure that reflect the observed temporary changes in auditory function can be obtained.......According to existing methods for the assessment of hearing damage, signals with the same A-weighted equivalent level should pose the same hazard to the auditory system. As a measure of hazard, it is assumed that Temporary Thresholds Shifts (TTS) reflect the onset of alterations to the hearing...

  10. PRISMES. The INES microgrid platform

    Energy Technology Data Exchange (ETDEWEB)

    Barruel, F.; Vervaart, M.; Merten, J. [INES, 73 - Le Bourget-du-lac (FR). Lab. for Solar Systems (L2S)

    2010-07-01

    The massive penetration of fluctuating renewable energies will challenge the low voltage grids. Innovative solutions to address this issue need to be developed and tested. They may consist of intelligent energy management systems and the use of storage systems. For this purpose the PRISMES platform has been designed and implemented at the INES headquarter in Chambery. It is a universal test and development tool, such as stand alone hybrid systems and grid connected PV systems combined with a storage system and loads. This paper describes the PRISMES facility which will start operation in autumn 2008. (orig.)

  11. Ines Karu tantsis end raamatusse / Kais Allkivi

    Index Scriptorium Estoniae

    Allkivi, Kais

    2008-01-01

    USAs ilmus raamat kõhutantsust "Kõhutants tähistamas püha naiselikkust" ("Belly Dance Celebrating the Sacred Feminine"). Raamatu autor on Martha Elena Burns. Eestlannadest on raamatus Ines Karu ja tema trupikaaslane Janne Mõistus. Lisaks fakte Ines Karust "Pühendunud tantsule"

  12. Progress in 'COE-INES'

    International Nuclear Information System (INIS)

    Sekimoto, Hiroshi

    2008-01-01

    In the year 2002 and 2003, the Japanese Ministry of Education, Culture Sports, Science and Technology started the 'The 21st Century Center of Excellence (COE) Program', which is planned to continue for 5 years. A program proposed by Tokyo Institute of Technology 'Innovative Nuclear Energy Systems for Sustainable Development of the World' simply called as COE-INES was selected as only one program in nuclear engineering field. The program consists of four main activities: research, education, society and internationalism. The research will be performed on the innovative nuclear energy systems, which include innovative nuclear reactors and innovative fuel cycles. Both free thinking and overall vision are taken on the research, and stressed on education also. In the education, COE-INES Captainship Program is promoted by integrating research with education, and we will foster creative researchers and engineers. Society is also a very important issue for nuclear energy. We try to coevolve nuclear energy with society and to strive towards the fulfillment of SR as well as to research innovative nuclear energy systems. We believe these ideas are occupied by many scientists in various countries. Then we are promoting the international collaboration for research and education on innovative nuclear energy systems. (author)

  13. Investigating the protective properties of milk phospholipids against ultraviolet light exposure in a skin equivalent model

    Science.gov (United States)

    Russell, Ashley; Laubscher, Andrea; Jimenez-Flores, Rafael; Laiho, Lily H.

    2010-02-01

    Current research on bioactive molecules in milk has documented health advantages of bovine milk and its components. Milk Phospholipids, selected for this study, represent molecules with great potential benefit in human health and nutrition. In this study we used confocal reflectance and multiphoton microscopy to monitor changes in skin morphology upon skin exposure to ultraviolet light and evaluate the potential of milk phospholipids in preventing photodamage to skin equivalent models. The results suggest that milk phospholipids act upon skin cells in a protective manner against the effect of ultraviolet (UV) radiation. Similar results were obtained from MTT tissue viability assay and histology.

  14. Operational experiences of INES in Japan

    International Nuclear Information System (INIS)

    1997-01-01

    Japan has introduced IAEA's INES in August, 1992. As of September, 1997, the total number of domestic nuclear events which have evaluated by using the INES system has amounted 119. In Japan, when a nuclear event occurs at a nuclear power plant, a provisional evaluation is performed immediately by Nuclear Power Operation Administration Office, MITI. The final evaluation of events is implemented a few months after event occurrence by the Evaluation Committee on Incidents and Failures of Nuclear Power Plant which holds a neutral position. The results of the evaluation are transmitted to IAEA according to the INES reporting criteria

  15. INES rating of radiation protection related events

    International Nuclear Information System (INIS)

    Hort, M.

    2009-01-01

    In this presentation, based on the draft Manual, a short review of the use of the INES rating of events concerning radiation protection is given, based on a new INES User's Manual edition. The presentation comprises a brief history of the scale development, general description of the scale and the main principles of the INES rating. Several examples of the use of the scale for radiation protection related events are mentioned. In the presentation, the term 'radiation protection related events' is used for radiation source and transport related events outside the nuclear installations. (authors)

  16. Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Nishizawa, Kanae; Kumamoto, Yoshikazu; Iwai, Kazuo; Mase, Naomichi.

    1993-01-01

    Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously calculated using a chord length technique and with data from ICRP publications. The annual collective effective dose equivalent were estimated to be about 21.94 person·Sv for medical workers, 7.73 person·Sv for industrial workers, 0.75 person·Sv for research and educational workers, 2.48 person·Sv for atomic energy industry and 84.4 person ·Sv for workers in nuclear power station. The population doses were calculated to be about 1.07 Sv for genetically significant dose, 0.89 Sv for leukemia significant dose and 0.42 Sv for malignant significant dose. The population risks were estimated using these population doses. (author)

  17. Individual monitoring of external exposure in terms of personal dose equivalent, Hp(d)

    International Nuclear Information System (INIS)

    Fantuzzi, E.

    2001-01-01

    The institute for Radiation Protection of ENEA - Bologna has organised a one day-workshop on the subject: Individual monitoring of external exposure in terms of personal dose equivalent, H p (d). The aim of the workshop was the discussion of the new implications and modifications to be expected in the routine individual monitoring of external radiation, due to the issue of the Decree 241/00 (G.U. 31/8/2000) in charge since 01/01/2001. The decree set up in Italian law the standards contained in the European Directive EURATOM 96/29-Basic Standards for the Protection of Health of Workers and the General Public against Dangers arising from Ionizing Radiation. Among others, the definition of the operational quantities for external radiation for personal and environmental monitoring, H p (d) e H * (d) respectively as defined by ICRU (International Commission for Radiation Units and Measurements), requires to update the methods of measurements and calibration of the personal dosemeters and environmental monitors. This report collects the papers presented at the workshop dealing with the Personal Dose Equivalent, H p (d), the conversion coefficients, H p (d)/K a e H p (d)/ , obtained through Monte Carlo calculations published by ICRU and ICRP (International Commission for Radiation Protection), the new calibration procedures and the practical implication in the routine of individual monitoring in terms of H p (d). Eventually, in the last chapter, the answers to Frequently Asked Questions (FAQ) are briefly reported [it

  18. A new method for generating distributions of biomonitoring equivalents to support exposure assessment and prioritization.

    Science.gov (United States)

    Phillips, Martin B; Sobus, Jon R; George, Barbara J; Isaacs, Kristin; Conolly, Rory; Tan, Yu-Mei

    2014-08-01

    Biomonitoring data are now available for hundreds of chemicals through state and national health surveys. Exposure guidance values also exist for many of these chemicals. Several methods are frequently used to evaluate biomarker data with respect to a guidance value. The "biomonitoring equivalent" (BE) approach estimates a single biomarker concentration (called the BE) that corresponds to a guidance value (e.g., Maximum Contaminant Level, Reference Dose, etc.), which can then be compared with measured biomarker data. The resulting "hazard quotient" estimates (HQ=biomarker concentration/BE) can then be used to prioritize chemicals for follow-up examinations. This approach is used exclusively for population-level assessments, and works best when the central tendency of measurement data is considered. Complementary approaches are therefore needed for assessing individual biomarker levels, particularly those that fall within the upper percentiles of measurement distributions. In this case study, probabilistic models were first used to generate distributions of BEs for perchlorate based on the point-of-departure (POD) of 7μg/kg/day. These distributions reflect possible biomarker concentrations in a hypothetical population where all individuals are exposed at the POD. A statistical analysis was then performed to evaluate urinary perchlorate measurements from adults in the 2001 to 2002 National Health and Nutrition Examination Survey (NHANES). Each NHANES adult was assumed to have experienced repeated exposure at the POD, and their biomarker concentration was interpreted probabilistically with respect to a BE distribution. The HQ based on the geometric mean (GM) urinary perchlorate concentration was estimated to be much lower than unity (HQ≈0.07). This result suggests that the average NHANES adult was exposed to perchlorate at a level well below the POD. Regarding individuals, at least a 99.8% probability was calculated for all but two NHANES adults that a higher

  19. INES- French application to radioactive material transport

    International Nuclear Information System (INIS)

    Sowinski, S.; Strawa, S.; Aguilar, J.

    2004-01-01

    After gaining control of radioactive material transport in June 1997, the French Nuclear Safety Authority (ASN) decided to apply the International Nuclear Event Scale (INES scale) to transport events. The Directorate General for Nuclear Safety and Radioprotection (DGSNR) requests that radioactive material package consignors declare any event occurring during transport, and has introduced the use of the INES scale adapted to classify transport events in order to inform the public and to have feedback. The INES scale is applicable to events arising in nuclear installations associated with the civil nuclear industry and events occurring during the transport of radioactive materials to and from them. The INES scale consists of seven levels. It is based on the successive application of three types of criterion (off-site impact, on-site impact and degradation of defence in depth) and uses the maximum level to determine the rating of an accident. As the transport in question takes place on public thoroughfares, only the off-site impact criteria and degradation of defence in-depth criteria apply. This paper deals with DGSNR's feedback during the past 7 years concerning the French application of the INES scale. Significant events that occurred during transport are presented. The French experience was used by the International Atomic Energy Agency (IAEA) to develop a draft guide in 2002 and the IAEA asked countries to use a new draft for a trial period in July 2004. (author)

  20. Report on the application of INES in Belgium

    International Nuclear Information System (INIS)

    1997-01-01

    The report on the application of INES in Belgium discusses the following topics: historical aspects; communication organization; communication policy in Belgium; events with difficulties or learning opportunities; public acceptance of INES issues; problems with the current systems

  1. Equivalent magnetic vector potential model for low-frequency magnetic exposure assessment

    Science.gov (United States)

    Diao, Y. L.; Sun, W. N.; He, Y. Q.; Leung, S. W.; Siu, Y. M.

    2017-10-01

    In this paper, a novel source model based on a magnetic vector potential for the assessment of induced electric field strength in a human body exposed to the low-frequency (LF) magnetic field of an electrical appliance is presented. The construction of the vector potential model requires only a single-component magnetic field to be measured close to the appliance under test, hence relieving considerable practical measurement effort—the radial basis functions (RBFs) are adopted for the interpolation of discrete measurements; the magnetic vector potential model can then be directly constructed by summing a set of simple algebraic functions of RBF parameters. The vector potentials are then incorporated into numerical calculations as the equivalent source for evaluations of the induced electric field in the human body model. The accuracy and effectiveness of the proposed model are demonstrated by comparing the induced electric field in a human model to that of the full-wave simulation. This study presents a simple and effective approach for modelling the LF magnetic source. The result of this study could simplify the compliance test procedure for assessing an electrical appliance regarding LF magnetic exposure.

  2. Experience with the INES scale in Egypt

    International Nuclear Information System (INIS)

    Rashad, S.M.

    1997-01-01

    Thirty years experience with Egypt first Research Reactor (ET-RR-1) operation, was introduced focusing on the famous events that were initiated and the procedures that were taken for their recovery or mitigation is given. Four out of seven events can be attributed to human errors, the events if classified using the INES

  3. Report on operation of INES. Swiss contribution

    International Nuclear Information System (INIS)

    Deutschmann, H.

    1997-01-01

    The presentation discusses the INES activities in Switzerland addressing the following issues: communication procedure for events of public interest; national reporting guidelines; changing information policy by regulatory body; practice of current event handling by regulatory body for faster public information; problems with public information

  4. Refinement of the bottom boundary of the INES scale

    International Nuclear Information System (INIS)

    Ferjencik, Milos

    2010-01-01

    No existing edition of the International Nuclear Events Scale (INES) Manual addresses in depth the determination of the bottom boundary of the Scale, although a need for a definition is felt. The article introduces a method for determining the INES bottom boundary applicable to pressurized water reactors. This bottom boundary is put identical with the threshold of degradation of the installation's nuclear safety assurance. A comprehensive flowchart has been developed as the main outcome of the analysis of the nuclear safety assurance violation issue. The use of this flowchart in INES classification to replace the introductory question in the General INES Rating Procedure in the INES Manual is recommended. (orig.)

  5. Basis for calculating body equivalent doses after external radiation exposure. 3. rev. and enl. ed.; Berechnungsgrundlage fuer die Ermittlung von Koerper-Aequivalentdosen bei aeusserer Strahlenexposition

    Energy Technology Data Exchange (ETDEWEB)

    Sarenio, O. (comp.) [Geschaeftsstelle der Strahlenschutzkommission beim Bundesamt fuer Strahlenschutz, Bonn (Germany)

    2017-07-01

    The book on the basis for calculating body equivalent doses after external radiation exposure includes the following issues: introduction covering the scope of coverage and body equivalent doses for radiation protection, terminology, photon radiation, neutron radiation, electron radiation, mixed radiation fields and the estimation of body equivalent doses for skin surface contamination.

  6. A method, using ICRP 26 weighting factors, to determine effective dose equivalent due to nonuniform external exposures

    International Nuclear Information System (INIS)

    Dyer, S.G.

    1993-01-01

    Westinghouse Savannah River Company (WSRC) has recently implemented a methodology and supporting procedures to calculate effective dose equivalent for external exposures. The calculations are based on ICRP 26 methodology and are used to evaluate exposures when multibadging is used. The methodology is based upon the concept of open-quotes whole bodyclose quotes compartmentalization (i.e., the whole body is separated into seven specific regions of radiological concern and weighted accordingly). The highest dose measured in each compartment is used to determine the weighted dose to that compartment. Benefits of determining effective dose equivalent are compliance with DOE Orders, more accurate dose assessments, and the opportunity for improved worker protection through new ALARA opportunities

  7. The INES is here to stay

    International Nuclear Information System (INIS)

    Mortin, S.J.

    1992-01-01

    The International Nuclear Event Scale (INES) was born in October 1989 at a meeting organised jointly by the IAEA and the OECD NEA. Delegates agreed that a scale was required to improve the effectiveness and consistency of communicating the significance of nuclear events to the public. The broad structure of the scale was also agreed but there were many detailed issues still to be resolved by international debate and compromise. Following meetings in January and March 1990, the scale was published for trial use. A summary of the scale, extracted from an IAEA leaflet, is given in this article. Most events are rated using the defence in depth criterion. The approach to rating events on this basis is also summarized. Full details are provided in the INES user manual. (author)

  8. SOILD: A computer model for calculating the effective dose equivalent from external exposure to distributed gamma sources in soil

    International Nuclear Information System (INIS)

    Chen, S.Y.; LePoire, D.; Yu, C.; Schafetz, S.; Mehta, P.

    1991-01-01

    The SOLID computer model was developed for calculating the effective dose equivalent from external exposure to distributed gamma sources in soil. It is designed to assess external doses under various exposure scenarios that may be encountered in environmental restoration programs. The models four major functional features address (1) dose versus source depth in soil, (2) shielding of clean cover soil, (3) area of contamination, and (4) nonuniform distribution of sources. The model is also capable of adjusting doses when there are variations in soil densities for both source and cover soils. The model is supported by a data base of approximately 500 radionuclides. 4 refs

  9. Homocyst(e)ine and stroke.

    Science.gov (United States)

    Furie, Karen L; Kelly, Peter J

    2006-02-01

    Homocyst(e)ine elevation is associated with a two- to threefold fold increased risk of ischemic stroke. Although most commonly associated with large-artery atherosclerosis and venous thrombosis, hyperhomocysteinemia may contribute to stroke by other mechanisms as well. Levels of homocysteine are determined by genetic regulation of the enzymes involved in homocyst(e)ine metabolism and by levels of the vitamin cofactors (folate, B (6), and B (12)) associated with those reactions. Emerging evidence suggests that genetic variation within this pathway, such as the methyleneterahydrofolate reductase and cystathionine beta-synthase and nicotinamide N-methyltransferase genes, increases the risk of ischemic stroke. The introduction of grain folate fortification in 1998 has reduced homocyst(e)ine concentrations in the U.S. population. However, it is important to screen for vitamin B (12) deficiency and be cognizant that vitamin B (6) levels may be low in the elderly and in individuals with inflammatory disorders. The Vitamin Intervention in Stroke Prevention study failed to prove that high-dose supplementation with folate, B (6), and B (12) reduced the risk of recurrent stroke or myocardial infarction at 2 years; however, there is an ongoing clinical trial evaluating the potential benefit of vitamin supplementation.

  10. Measurement of cardiopulmonary performance during acute exposure to a 2440-m equivalent atmosphere

    Science.gov (United States)

    Levitan, B. M.; Bungo, M. W.

    1982-01-01

    Each of 20 subjects (ranging in age from 18 to 38 years, 15 being male, five female) was given two Bruce Protocol symptom-limited maximum treadmill stress tests, breathing sea-level compressed air (20.9% O2) for one test and a 2440-m equivalent (15.5% O2) for the other. A significant difference was found to exist between measured VO2 max (p less than 0.0002) and exercise time (p less than 0.0004) for the two conditions. No significant differences were observed in heart rate or the recovery time to a respiratory quotient of less than 1. Hemoglobin saturation, as measured by an ear oximeter, averaged 95% for sea-level and 91% for the 2440-m equivalent gases. These results support a 2440-m equivalent contingency atmosphere in the Space Shuttle prior to donning a low-pressure suit for the purpose reducing nitrogen washout times.

  11. MUTZ-3 derived Langerhans cells in human skin equivalents show differential migration and phenotypic plasticity after allergen or irritant exposure

    Energy Technology Data Exchange (ETDEWEB)

    Kosten, Ilona J.; Spiekstra, Sander W. [Department of Dermatology, VU University Medical Center, Amsterdam (Netherlands); Gruijl, Tanja D. de [Department of Dermatology Medical Oncology, VU University Medical Center, Amsterdam (Netherlands); Gibbs, Susan, E-mail: s.gibbs@acta.nl [Department of Dermatology, VU University Medical Center, Amsterdam (Netherlands); Department of Oral Cell Biology, Academic Center for Dentistry (ACTA), Amsterdam (Netherlands)

    2015-08-15

    After allergen or irritant exposure, Langerhans cells (LC) undergo phenotypic changes and exit the epidermis. In this study we describe the unique ability of MUTZ-3 derived Langerhans cells (MUTZ-LC) to display similar phenotypic plasticity as their primary counterparts when incorporated into a physiologically relevant full-thickness skin equivalent model (SE-LC). We describe differences and similarities in the mechanisms regulating LC migration and plasticity upon allergen or irritant exposure. The skin equivalent consisted of a reconstructed epidermis containing primary differentiated keratinocytes and CD1a{sup +} MUTZ-LC on a primary fibroblast-populated dermis. Skin equivalents were exposed to a panel of allergens and irritants. Topical exposure to sub-toxic concentrations of allergens (nickel sulfate, resorcinol, cinnamaldehyde) and irritants (Triton X-100, SDS, Tween 80) resulted in LC migration out of the epidermis and into the dermis. Neutralizing antibody to CXCL12 blocked allergen-induced migration, whereas anti-CCL5 blocked irritant-induced migration. In contrast to allergen exposure, irritant exposure resulted in cells within the dermis becoming CD1a{sup −}/CD14{sup +}/CD68{sup +} which is characteristic of a phenotypic switch of MUTZ-LC to a macrophage-like cell in the dermis. This phenotypic switch was blocked with anti-IL-10. Mechanisms previously identified as being involved in LC activation and migration in native human skin could thus be reproduced in the in vitro constructed skin equivalent model containing functional LC. This model therefore provides a unique and relevant research tool to study human LC biology in situ under controlled in vitro conditions, and will provide a powerful tool for hazard identification, testing novel therapeutics and identifying new drug targets. - Highlights: • MUTZ-3 derived Langerhans cells integrated into skin equivalents are fully functional. • Anti-CXCL12 blocks allergen-induced MUTZ-LC migration.

  12. DEEP code to calculate dose equivalents in human phantom for external photon exposure by Monte Carlo method

    International Nuclear Information System (INIS)

    Yamaguchi, Yasuhiro

    1991-01-01

    The present report describes a computer code DEEP which calculates the organ dose equivalents and the effective dose equivalent for external photon exposure by the Monte Carlo method. MORSE-CG, Monte Carlo radiation transport code, is incorporated into the DEEP code to simulate photon transport phenomena in and around a human body. The code treats an anthropomorphic phantom represented by mathematical formulae and user has a choice for the phantom sex: male, female and unisex. The phantom can wear personal dosimeters on it and user can specify their location and dimension. This document includes instruction and sample problem for the code as well as the general description of dose calculation, human phantom and computer code. (author)

  13. The risk equivalent of an exposure to-, versus a dose of radiation

    International Nuclear Information System (INIS)

    Bond, V.P.

    1986-01-01

    The long-term potential carcinogenic effects of low-level exposure (LLE) are addressed. The principal point discussed is linear, no-threshold dose-response curve. That the linear no-threshold, or proportional relationship is widely used is seen in the way in which the values for cancer risk coefficients are expressed - in terms of new cases, per million persons exposed, per year, per unit exposure or dose. This implies that the underlying relationship is proportional, i.e., ''linear, without threshold''. 12 refs., 9 figs., 1 tab

  14. The International Nuclear Event Scale (INES) user's manual. 2001 edition

    International Nuclear Information System (INIS)

    2001-12-01

    The International Nuclear Event Scale (INES) was introduced in March 1990 jointly by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development (OECD/NEA). Its primary purpose is to facilitate communication and understanding between the nuclear community, the media and the public on the safety significance of events occurring at nuclear installations. The scale was refined in 1992 in the light of experience gained and extended to be applicable to any event associated with radioactive material and/or radiation, including the transport of radioactive materials.This edition of the INES User's Manual incorporates experience gained from applying the 1992 version of the scale and the document entitled 'Clarification of Issues Raised'. As such, it replaces those earlier publications. It does not amend the technical basis of the INES rating procedure but is expected to facilitate the task of those who are required to rate the safety significance of events using the INES scale. The INES communication network currently receives and disseminates event information to the INES National Officers of 60 Member States on special Event Rating Forms which represent official information on the events, including the rating. The INES communication process has led each participating country to set up an internal network which ensures that all events are promptly communicated and rated whenever they have to be reported outside or inside the country. The IAEA provides training services on the use of INES on request

  15. Emotion based Agent Architectures for Tutoring Systems : The INES Architecture

    NARCIS (Netherlands)

    Poel, Mannes; op den Akker, Rieks; Heylen, Dirk; Nijholt, Anton; Trappl, Robert

    2004-01-01

    In this paper we discuss our approach to integrate emotions in the agent based tutoring system INES (Intelligent Nursing Education System). First we discuss the INES system where we emphasize the emotional component of the system. Afterwards we show how a more advanced emotion generation

  16. Emotion based Agent Architectures for Tutoring Systems: The INES Architecture

    NARCIS (Netherlands)

    Poel, Mannes; op den Akker, Hendrikus J.A.; Heylen, Dirk K.J.; Nijholt, Antinus; Trappl, R.

    2004-01-01

    In this paper we discuss our approach to integrate emotions in the agent based tutoring system INES (Intelligent Nursing Education System). First we discuss the INES system where we emphasize the emotional component of the system. Afterwards we show how a more advanced emotion generation

  17. Niacin treatment increases plasma homocyst(e)ine levels.

    Science.gov (United States)

    Garg, R; Malinow, M; Pettinger, M; Upson, B; Hunninghake, D

    1999-12-01

    Studies have reported high levels of plasma homocyst(e)ine as an independent risk factor for arterial occlusive disease. The Cholesterol Lowering Atherosclerosis Study reported an increase in plasma homocyst(e)ine levels in patients receiving both colestipol and niacin compared with placebo. Thus the objective of this study was to examine the effect of niacin treatment on plasma homocyst(e)ine levels. The Arterial Disease Multiple Intervention Trial, a multicenter randomized, placebo-controlled trial, examined the effect of niacin compared with placebo on homocyst(e)ine in a subset of 52 participants with peripheral arterial disease. During the screening phase, titration of niacin dose from 100 mg to 1000 mg daily resulted in a 17% increase in mean plasma homocyst(e)ine level from 13.1 +/- 4.4 micromol/L to 15.3 +/- 5.6 micromol/L (P ine levels in the niacin group and a 7% decrease in the placebo group (P =.0001). This difference remained statistically significant at the end of follow-up at 48 weeks. Niacin substantially increased plasma homocyst(e)ine levels, which could potentially reduce the expected benefits of niacin associated with lipoprotein modification. However, plasma homocyst(e)ine levels can be decreased by folic acid supplementation. Thus further studies are needed to determine whether B vitamin supplementation to patients undergoing long-term niacin treatment would be beneficial.

  18. INES - The International Nuclear Event Scale. User's manual

    International Nuclear Information System (INIS)

    2005-01-01

    The International Nuclear Event Scale (INES) was introduced in March 1990 jointly by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development (OECD/NEA). Its primary purpose is to facilitate communication and understanding between the nuclear community, the media and the public on the safety significance of events occurring at nuclear installations. The scale was refined in 1992 in the light of experience gained and extended to be applicable to any event associated with radioactive material and/or radiation, including the transport of radioactive materials. This edition of the INES User's Manual incorporates experience gained from applying the 1992 version of the scale and the document entitled 'Clarification of Issues Raised'. As such, it replaces those earlier publications. It does not amend the technical basis of the INES rating procedure but is expected to facilitate the task of those who are required to rate the safety significance of events using the INES scale. The INES communication network currently receives and disseminates event information to the INES National Officers of 60 Member States on special Event Rating Forms which represent official information on the events, including the rating. The INES communication process has led each participating country to set up an internal network which ensures that all events are promptly communicated and rated whenever they have to be reported outside or inside the country. The IAEA provides training services on the use of INES on request

  19. Homocyst(e)ine impairs endocardial endothelial function.

    Science.gov (United States)

    Tyagi, S C; Smiley, L M; Mujumdar, V S

    1999-12-01

    Homocyst(e)ine injured vascular endothelium and modulated endothelial-dependent vascular function. Endothelium plays an analogous role in both the vessel and the endocardium. Therefore, we hypothesized that homocyst(e)ine modulated endocardial endothelium (EE) dependent cardiac function. The ex vivo cardiac rings from normal male Wistar-Kyoto rats were prepared. The contractile responses of left and right ventricular rings were measured in an isometric myobath, using different concentrations of CaCl2. The response was higher in the left ventricle than right ventricle and was elevated in endocardium without endothelium. The half effective concentration (EC50) and maximum tension generated by homocyst(e)ine were 10(6) and 5-fold lower than endothelin (ET) and angiotensin II (AII), respectively. However, in endothelial-denuded endocardium, homocyst(e)ine response was significantly increased (pine, and endothelial nitric oxide in EE function, cardiac rings were pretreated with AII (10(-10) M) or ET (10(-13) M) and then treated with homocyst(e)ine (10(-8) M). Results suggested that at these concentrations AII, ET, or homocyst(e)ine alone had no effect on cardiac contraction. However, in the presence of 10(-10) M AII or 10(-13) M ET, the cardiac contraction to homocyst(e)ine (10(-8) M) was significantly enhanced (pine. These results suggested that homocyst(e)ine impaired EE-dependent cardiac function and acted synergistically with AII and ET in enhancing the cardiac contraction.

  20. The International Nuclear Event Scale (INES) user's manual. 2001 edition

    International Nuclear Information System (INIS)

    2001-02-01

    The International Nuclear Event Scale (INES) was introduced in March 1990 jointly by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development (OECD/NEA). Its primary purpose is to facilitate communication and understanding between the nuclear community, the media and the public on the safety significance of events occurring at nuclear installations. The scale was refined in 1992 in the light of experience gained and extended to be applicable to any event associated with radioactive material and/or radiation, including the transport of radioactive materials.This edition of the INES User's Manual incorporates experience gained from applying the 1992 version of the scale and the document entitled ''Clarification of Issues Raised''. As such, it replaces those earlier publications. It does not amend the technical basis of the INES rating procedure but is expected to facilitate the task of those who are required to rate the safety significance of events using the INES scale. The INES communication network currently receives and disseminates event information to the INES National Officers of 60 Member States on special Event Rating Forms which represent official information on the events, including the rating. The INES communication process has led each participating country to set up an internal network which ensures that all events are promptly communicated and rated whenever they have to be reported outside or inside the country. The IAEA provides training services on the use of INES on request

  1. The cyclophosphamide equivalent dose as an approach for quantifying alkylating agent exposure: a report from the Childhood Cancer Survivor Study.

    Science.gov (United States)

    Green, Daniel M; Nolan, Vikki G; Goodman, Pamela J; Whitton, John A; Srivastava, DeoKumar; Leisenring, Wendy M; Neglia, Joseph P; Sklar, Charles A; Kaste, Sue C; Hudson, Melissa M; Diller, Lisa R; Stovall, Marilyn; Donaldson, Sarah S; Robison, Leslie L

    2014-01-01

    Estimation of the risk of adverse long-term outcomes such as second malignant neoplasms and infertility often requires reproducible quantification of exposures. The method for quantification should be easily utilized and valid across different study populations. The widely used Alkylating Agent Dose (AAD) score is derived from the drug dose distribution of the study population and thus cannot be used for comparisons across populations as each will have a unique distribution of drug doses. We compared the performance of the Cyclophosphamide Equivalent Dose (CED), a unit for quantifying alkylating agent exposure independent of study population, to the AAD. Comparisons included associations from three Childhood Cancer Survivor Study (CCSS) outcome analyses, receiver operator characteristic (ROC) curves and goodness of fit based on the Akaike's Information Criterion (AIC). The CED and AAD performed essentially identically in analyses of risk for pregnancy among the partners of male CCSS participants, risk for adverse dental outcomes among all CCSS participants and risk for premature menopause among female CCSS participants, based on similar associations, lack of statistically significant differences between the areas under the ROC curves and similar model fit values for the AIC between models including the two measures of exposure. The CED is easily calculated, facilitating its use for patient counseling. It is independent of the drug dose distribution of a particular patient population, a characteristic that will allow direct comparisons of outcomes among epidemiological cohorts. We recommend the use of the CED in future research assessing cumulative alkylating agent exposure. © 2013 Wiley Periodicals, Inc.

  2. Self-reported sleep disturbances due to railway noise: exposure-response relationships for nighttime equivalent and maximum noise levels.

    Science.gov (United States)

    Aasvang, Gunn Marit; Moum, Torbjorn; Engdahl, Bo

    2008-07-01

    The objective of the present survey was to study self-reported sleep disturbances due to railway noise with respect to nighttime equivalent noise level (L(p,A,eq,night)) and maximum noise level (L(p,A,max)). A sample of 1349 people in and around Oslo in Norway exposed to railway noise was studied in a cross-sectional survey to obtain data on sleep disturbances, sleep problems due to noise, and personal characteristics including noise sensitivity. Individual noise exposure levels were determined outside of the bedroom facade, the most-exposed facade, and inside the respondents' bedrooms. The exposure-response relationships were analyzed by using logistic regression models, controlling for possible modifying factors including the number of noise events (train pass-by frequency). L(p,A,eq,night) and L(p,A,max) were significantly correlated, and the proportion of reported noise-induced sleep problems increased as both L(p,A,eq,night) and L(p,A,max) increased. Noise sensitivity, type of bedroom window, and pass-by frequency were significant factors affecting noise-induced sleep disturbances, in addition to the noise exposure level. Because about half of the study population did not use a bedroom at the most-exposed side of the house, the exposure-response curve obtained by using noise levels for the most-exposed facade underestimated noise-induced sleep disturbance for those who actually have their bedroom at the most-exposed facade.

  3. INES application in Kazakhstan, annual review

    International Nuclear Information System (INIS)

    Krechetov, S.

    1997-01-01

    For the period from the last TCM meeting all Kazakhstani facilities operated rather good. Only one event which attracted public attention occurred at BN-350 on 23 March and was rated as level 0. It had been reported according to INES procedure. I would like to suggest the TCM participants some additional information related to our nuclear activities in Kazakhstan. Our first own law of the Atomic energy use put into force on 14th of April 1997. The research reactor WWER-K nearby to Almaty after 8 years under shutdown reached first critically on 18 April under restarting program. The program to restart of the reactor have to be completed at the end of this year. For the improvement of the relations with the public since this year IAEA started to provide our government TV channel the information about safety status and radiation situation at and around of the nuclear facilities on weekly basis

  4. The INE-Beamline for Actinide Research at ANKA

    Science.gov (United States)

    Brendebach, Boris; Denecke, Melissa A.; Rothe, Jörg; Dardenne, Kathy; Römer, Jürgen

    2007-02-01

    The INE-Beamline for actinide research at the synchrotron source ANKA is now fully operational. This beamline was designed, built, and commissioned by the Institut für Nukleare Entsorgung (INE) at the Forschungszentrum Karlsruhe (FZK), Germany. It is dedicated to actinide speciation investigations related to nuclear waste disposal as well as applied and basic actinide research. Experiments on radioactive samples with activities up to 106 times the limit of exemption inside a safe and flexible double containment concept are possible. The close proximity of the beamline to INE's active laboratories is unique in Europe. Currently, experiments can be performed in an X-ray energy range from around 2.15 keV (P K edge) to 24.35 keV (Pd K edge). The INE-Beamline design is optimized for spectroscopy with emphasis on surface sensitive techniques. A microfocus option is presently being installed at the INE-Beamline. Access to the INE-Beamline is possible through cooperation with INE, through the ANKA proposal system and via the European Network of Excellence for Actinide Sciences (ACTINET).

  5. Report of the application of the INES in Croatia

    International Nuclear Information System (INIS)

    Valcic, I.

    1997-01-01

    The Republic of Croatia has no nuclear installation, no power reactors, no research reactors, nor any other nuclear fuel circle installations, on its territory. All facilities with installations and/or equipment for application of ionising radiation (irradiators, accelerators, sealed sources etc.) have operated without radiation safety relevant incidents. Also all transport activities have been carried out without any safety relevant incidents. Consequently, no one abnormal event was rated in Croatia using INES in period Oct. 1996 - Oct. 1997, and no INES report was communicated to the INES information system

  6. INES information system - Feedback from India 1996-97

    International Nuclear Information System (INIS)

    Kumar, S.V.

    1997-01-01

    International Nuclear Events Scale is in use for the past seven years and has proved to be an effective tool of communication between the nuclear community, the media and the public for safety significance of an event occurring in nuclear facilities. India is an active participant in INES programme and using the INES from its inception. India regularly sends 'Event Rating Forms' to IAEA for events occurring at Indian Nuclear Installations. This paper gives a brief account of INES activities in India during 1996 - 1997

  7. A theoretical study for the real-time assessment of external gamma exposure using equivalent-volume numerical integration

    International Nuclear Information System (INIS)

    Han, Moon Hee

    1995-02-01

    An approximate method for estimating gamma external dose due to an arbitrary distribution of radioactive material has been developed. For the assessment of external gamma dose, the space over which radioactive material is distributed has been assumed to be composed of hexagonal cells. The evaluation of three-dimensional integration over the space is an extremely time-consuming task. Hence, a different approach has been used for the study, i.e., a equivalent-volume spherical approach in which a regular hexahedron is modeled as a equivalent-volume sphere to simplify the integration. For the justification of the current approach, two case studies have been performed: a comparison with a point source approximation and a comparison of external dose rate with the Monte Carlo integration. These comparisons show that the current approach gives reasonable results in a physical sense. Computing times of the developed and Monte Carlo integration method on VAX system have been compared as a function of the number of hexagonal cells. This comparison shows that CPU times for both methods are comparable in the region of small number of cells, but in the region of large number, Monte Carlo integration needs much more computing times. The proposed method is shown to have an accuracy equivalent to Monte Carlo method with an advantage of much shorter calculation time. Then, the method developed here evaluates early off-site consequences of a nuclear accident. An accident consequence assessment model has been integrated using Gaussian puff model which is used to obtain the distribution of radioactive material in the air and on the ground. For this work, the real meteorological data measured at Kori site for 10 years (1976 - 1985) have been statistically analyzed for obtaining site-specific conditions. The short-term external gamma exposures have been assessed for several site-specific meteorological conditions. The results show that the extent and the pattern of short-term external

  8. Communicating about nuclear events: Some suggestions to improve INES

    International Nuclear Information System (INIS)

    Kermisch, Céline; Labeau, Pierre-Etienne

    2013-01-01

    This paper provides a critical analysis of the International Nuclear and Radiological Event Scale (INES) and its use, both from an epistemic and an ethical perspective. As very few papers have been dedicated to this subject, our critical analysis is mainly based on the INES 2009 User's Manual and on technical information issued by different nuclear agencies. Our critical analysis leads to suggest several elements, which could contribute to the improvement of the INES scale and thereby to a better communication about nuclear events. First, we show that multiple criteria are used to assign an INES rating, which could lead to an insufficient differentiation between events. In order to avoid this issue, we suggest to clarify the criteria that are used to assess the level of the event. Then, we show that level 7 of the INES scale is ill-defined as it does not allow to properly take differences in severity between disasters into account. In this regard, we recommend to use an open scale instead. Moreover, we highlight the fact that INES is able to take into account neither events with long-term evolution nor events involving multiple initiators. In this respect, we suggest providing additional guidelines and reflecting about the data on which to rely, in order to assess an INES level. Furthermore, we reflect on who should be rating a nuclear event and we recommend that, for severe events, an independent and plural agency should be in charge. Finally, we show why INES appears to be insufficient for a global communication, and we suggest to complement the INES rating with additional information in parallel. -- Highlights: •We provide a critical analysis of the INES scale and suggestions to improve it. •The rating criteria should be clarified to allow differentiation between events. •An open scale should be used to differentiate between level-7 accidents. •Additional guidelines should be provided for complex and evolving events. •We provide suggestions to satisfy

  9. Serum homocyst(e)ine levels in women with preeclampsia.

    Science.gov (United States)

    Mayerhofer, K; Hefler, L; Zeisler, H; Tempfer, C; Bodner, K; Stöckler-Ipsiroglu, S; Mühl, A; Kaider, A; Schatten, C; Leodolter, S; Husslein, P; Kainz, C

    2000-03-24

    Endothelial dysfunction has been described as the final common pathophysiological pathway in the development of preeclampsia. Since it has been suggested that homocyst(e)ine damages endothelial cells, we measured serum homocyst(e)ine levels in women with preeclampsia and in healthy pregnant women in order to find a new prognostic parameter for women with preeclampsia. Forty-five women with preeclampsia and 45 healthy women with uncomplicated pregnancies, matched for age and parity, were entered into the study. Serum homocyst(e)ine levels were measured by gas chromatography-mass spectrometry analysis and correlated to clinical data. Logistic regression models were used to analyse the influence of serum homocyst(e)ine levels on the presence of preeclampsia versus healthy pregnant women and on the risk of premature termination of pregnancy due to preeclampsia. Median serum homocyst(e)ine levels in women with preeclampsia and healthy pregnant women were 14.2 (range 5.7-38.1) mumol/L and 15.1 (range 5.2-23.1) mumol/L, respectively (Mann-Whitney U-test, p = 0.8). In univariate logistic regression models, serum homocyst(e)ine levels had no significant influence on the odds of presenting with preeclampsia versus healthy pregnant women (univariate logistic regression model, p = 0.8) and on the odds of premature termination of pregnancy due to preeclampsia (univariate logistic regression model, p = 0.3). Serum homocyst(e)ine levels are not elevated in women with preeclampsia and are not associated with clinical outcome in women with preeclampsia.

  10. INE: a rice genome database with an integrated map view.

    Science.gov (United States)

    Sakata, K; Antonio, B A; Mukai, Y; Nagasaki, H; Sakai, Y; Makino, K; Sasaki, T

    2000-01-01

    The Rice Genome Research Program (RGP) launched a large-scale rice genome sequencing in 1998 aimed at decoding all genetic information in rice. A new genome database called INE (INtegrated rice genome Explorer) has been developed in order to integrate all the genomic information that has been accumulated so far and to correlate these data with the genome sequence. A web interface based on Java applet provides a rapid viewing capability in the database. The first operational version of the database has been completed which includes a genetic map, a physical map using YAC (Yeast Artificial Chromosome) clones and PAC (P1-derived Artificial Chromosome) contigs. These maps are displayed graphically so that the positional relationships among the mapped markers on each chromosome can be easily resolved. INE incorporates the sequences and annotations of the PAC contig. A site on low quality information ensures that all submitted sequence data comply with the standard for accuracy. As a repository of rice genome sequence, INE will also serve as a common database of all sequence data obtained by collaborating members of the International Rice Genome Sequencing Project (IRGSP). The database can be accessed at http://www. dna.affrc.go.jp:82/giot/INE. html or its mirror site at http://www.staff.or.jp/giot/INE.html

  11. INES scale: French application to radioactive material transport

    International Nuclear Information System (INIS)

    Sowinski, S.; Strawa, S.; Aguilar, J.

    2004-01-01

    After getting the control of radioactive material transport in June 1997, the French safety Authority (ASN) decided to apply the INES scale to transport events. DGSNR (Directorate General for Nuclear Safety and Radioprotection) requests that radioactive material package consignors declare any event occurring during transportation, and has introduced the use of the INES scale adapted to classify transport events in order to inform the public and to have feedback. This paper deals with DGSNR's feedback during the past seven years concerning the french application of the INES scale. Significant events that occurred during transportation are presented. The French experience was used by IAEA to develop a draft guide in 2002 and IAEA asked countries to use a new draft for a trial period in July 2004

  12. Characterization of a neutron imaging setup at the INES facility

    Science.gov (United States)

    Durisi, E. A.; Visca, L.; Albertin, F.; Brancaccio, R.; Corsi, J.; Dughera, G.; Ferrarese, W.; Giovagnoli, A.; Grassi, N.; Grazzi, F.; Lo Giudice, A.; Mila, G.; Nervo, M.; Pastrone, N.; Prino, F.; Ramello, L.; Re, A.; Romero, A.; Sacchi, R.; Salvemini, F.; Scherillo, A.; Staiano, A.

    2013-10-01

    The Italian Neutron Experimental Station (INES) located at the ISIS pulsed neutron source (Didcot, United Kingdom) provides a thermal neutron beam mainly used for diffraction analysis. A neutron transmission imaging system was also developed for beam monitoring and for aligning the sample under investigation. Although the time-of-flight neutron diffraction is a consolidated technique, the neutron imaging setup is not yet completely characterized and optimized. In this paper the performance for neutron radiography and tomography at INES of two scintillator screens read out by two different commercial CCD cameras is compared in terms of linearity, signal-to-noise ratio, effective dynamic range and spatial resolution. In addition, the results of neutron radiographies and a tomography of metal alloy test structures are presented to better characterize the INES imaging capabilities of metal artifacts in the cultural heritage field.

  13. ANALIZA PRIMEROV UPORABE VELIKE KOLIČINE PODATKOV

    OpenAIRE

    Koželj, Marko

    2013-01-01

    Diplomski seminar predstavlja računalništvo v oblaku in velike količine podatkov. Ta dva pojma sta novi poslovni priložnosti za podjetja. Vsekakor bodo brez teh dveh inovacij podjetja težko preživela na mednarodnih trgih. V diplomskem seminarju smo obravnavali računalništvo v oblaku. Na kratko smo povedali osnovne značilnosti, razvoj skozi leta, arhitekturo, tipe in SWOT analizo računalništva v oblaku. Kasneje smo se osredotočili na velike količine podatkov, jih definirali, pojasnili zgod...

  14. The relationship between maternal and neonatal umbilical cord plasma homocyst(e)ine suggests a potential role for maternal homocyst(e)ine in fetal metabolism.

    Science.gov (United States)

    Malinow, M R; Rajkovic, A; Duell, P B; Hess, D L; Upson, B M

    1998-02-01

    Data on fetal blood homocyst(e)ine concentrations are not available. We tested the hypothesis that homocyst(e)ine crosses the maternal/placental/fetal interphases and is sequestered by the fetus. The concentration of homocyst(e)ine was determined at parturition in peripheral venous plasma from 35 nulliparous healthy pregnant women and umbilical arterial and venous plasma from their conceptus. Findings demonstrated a descending concentration gradient of plasma homocyst(e)ine from maternal vein to umbilical vein and to umbilical artery; the decrease at each interphase approximated 1 micromol/L. The neonate weight and gestational age were inversely related to maternal homocyst(e)ine concentrations. The umbilical vein to umbilical artery homocyst(e)ine decrement suggests that uptake of homocyst(e)ine occurs in the fetus. The likely incorporation of homocyst(e)ine into the fetal metabolic cycle may implicate maternal homocyst(e)ine as having a potential nutritional role in the fetus. Further studies are required to explain the role of homocyst(e)ine in fetal metabolism and development.

  15. Revision and psychometric testing of the Incivility in Nursing Education (INE) survey: introducing the INE-R.

    Science.gov (United States)

    Clark, Cynthia M; Barbosa-Leiker, Celestina; Gill, Larecia Money; Nguyen, Danh

    2015-06-01

    Academic incivility is a serious challenge for nursing education, which needs to be empirically measured and fully addressed. A convenience sample of nursing faculty and students from 20 schools of nursing in the United States participated in a mixed-methods study to test the psychometric properties of the Incivility in Nursing Education-Revised (INE-R) Survey. A factor analysis and other reliability analyses support the use of the INE-R as a valid and reliable measurement of student and faculty perceptions of incivility in nursing education. The INE-R is a psychometrically sound instrument to measure faculty and student perceptions of incivility; to examine differences regarding levels of nursing education, program type, gender, age, and ethnicity; to compare perceptions of incivility between and among adjunct, clinical, teaching, and research faculty; and to conduct pre- and postassessments of the perceived levels of faculty and student incivility in nursing programs to inform evidence-based interventions. Copyright 2015, SLACK Incorporated.

  16. Plasma folic acid cutoff value, derived from its relationship with homocyst(e)ine

    NARCIS (Netherlands)

    Brouwer, D A; Welten, H T; Reijngoud, D J; van Doormaal, J J; Muskiet, F A

    We established the cutoff value for plasma folic acid, using plasma homocyst(e)ine as the functional marker. To do this, we investigated the relationship of the plasma folic acid of 103 apparently healthy adults with their fasting plasma homocyst(e)ine and with their plasma homocyst(e)ine 6 h after

  17. Timo Palo jäine väljakutse

    Index Scriptorium Estoniae

    2014-01-01

    Fotonäitusest "Jäine väljakutse". Näitus koosneb kahest osast: National Geographicu fotograafi Paul Nickleni fotodest "Polar Obsession" ja Eesti polaarränduri Timo Palo retke põhjapooluselt Teravmägede saarestikku kirjeldavast väljapanekust

  18. Characterization of a neutron imaging setup at the INES facility

    Energy Technology Data Exchange (ETDEWEB)

    Durisi, E.A., E-mail: elisabettaalessandra.durisi@unito.it [Università di Torino, Dipartimento di Fisica, Via Pietro Giuria 1, 10125 Torino (Italy); Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Visca, L. [Università di Torino, Dipartimento di Fisica, Via Pietro Giuria 1, 10125 Torino (Italy); Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Albertin, F.; Brancaccio, R. [Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Corsi, J. [Università di Torino, Dipartimento di Fisica, Via Pietro Giuria 1, 10125 Torino (Italy); Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Dughera, G. [Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Ferrarese, W. [Università di Torino, Dipartimento di Fisica, Via Pietro Giuria 1, 10125 Torino (Italy); Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Giovagnoli, A.; Grassi, N. [Fondazione Centro per la Conservazione ed il Restauro dei Beni Culturali “La Venaria Reale”, Piazza della Repubblica, 10078 Venaria Reale, Torino (Italy); Grazzi, F. [Consiglio Nazionale delle Ricerche, Istituto dei Sistemi Complessi, Via Madonna del Piano 10, 50019 Sesto Fiorentino, Firenze (Italy); Lo Giudice, A.; Mila, G. [Università di Torino, Dipartimento di Fisica, Via Pietro Giuria 1, 10125 Torino (Italy); Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); and others

    2013-10-21

    The Italian Neutron Experimental Station (INES) located at the ISIS pulsed neutron source (Didcot, United Kingdom) provides a thermal neutron beam mainly used for diffraction analysis. A neutron transmission imaging system was also developed for beam monitoring and for aligning the sample under investigation. Although the time-of-flight neutron diffraction is a consolidated technique, the neutron imaging setup is not yet completely characterized and optimized. In this paper the performance for neutron radiography and tomography at INES of two scintillator screens read out by two different commercial CCD cameras is compared in terms of linearity, signal-to-noise ratio, effective dynamic range and spatial resolution. In addition, the results of neutron radiographies and a tomography of metal alloy test structures are presented to better characterize the INES imaging capabilities of metal artifacts in the cultural heritage field. -- Highlights: A full characterization of the present INES imaging set-up was carried out. Two CCD cameras and two scintillators (ZnS/{sup 6}LiF) of different thicknesses were tested. Linearity, effective dynamic range and spatial resolution were determined. Radiographies of steep wedges were performed using the highest dynamic range setup. Tomography of a bronze cube was performed using the best spatial resolution setup.

  19. Characterization of a neutron imaging setup at the INES facility

    International Nuclear Information System (INIS)

    Durisi, E.A.; Visca, L.; Albertin, F.; Brancaccio, R.; Corsi, J.; Dughera, G.; Ferrarese, W.; Giovagnoli, A.; Grassi, N.; Grazzi, F.; Lo Giudice, A.; Mila, G.

    2013-01-01

    The Italian Neutron Experimental Station (INES) located at the ISIS pulsed neutron source (Didcot, United Kingdom) provides a thermal neutron beam mainly used for diffraction analysis. A neutron transmission imaging system was also developed for beam monitoring and for aligning the sample under investigation. Although the time-of-flight neutron diffraction is a consolidated technique, the neutron imaging setup is not yet completely characterized and optimized. In this paper the performance for neutron radiography and tomography at INES of two scintillator screens read out by two different commercial CCD cameras is compared in terms of linearity, signal-to-noise ratio, effective dynamic range and spatial resolution. In addition, the results of neutron radiographies and a tomography of metal alloy test structures are presented to better characterize the INES imaging capabilities of metal artifacts in the cultural heritage field. -- Highlights: A full characterization of the present INES imaging set-up was carried out. Two CCD cameras and two scintillators (ZnS/ 6 LiF) of different thicknesses were tested. Linearity, effective dynamic range and spatial resolution were determined. Radiographies of steep wedges were performed using the highest dynamic range setup. Tomography of a bronze cube was performed using the best spatial resolution setup

  20. Construction of computational program of aging in insulating materials for searching reversed sequential test conditions to give damage equivalent to simultaneous exposure of heat and radiation

    International Nuclear Information System (INIS)

    Fuse, Norikazu; Homma, Hiroya; Okamoto, Tatsuki

    2013-01-01

    Two consecutive numerical calculations on degradation of polymeric insulations under thermal and radiation environment are carried out to simulate so-called reversal sequential acceleration test. The aim of the calculation is to search testing conditions which provide material damage equivalent to the case of simultaneous exposure of heat and radiation. At least following four parameters are needed to be considered in the sequential method; dose rate and exposure time in radiation, as well as temperature and aging time in heating. The present paper discusses the handling of these parameters and shows some trial calculation results. (author)

  1. The INE-Beamline for actinide science at ANKA

    Science.gov (United States)

    Rothe, J.; Butorin, S.; Dardenne, K.; Denecke, M. A.; Kienzler, B.; Löble, M.; Metz, V.; Seibert, A.; Steppert, M.; Vitova, T.; Walther, C.; Geckeis, H.

    2012-04-01

    Since its inauguration in 2005, the INE-Beamline for actinide research at the synchrotron source ANKA (KIT North Campus) provides dedicated instrumentation for x-ray spectroscopic characterization of actinide samples and other radioactive materials. R&D work at the beamline focuses on various aspects of nuclear waste disposal within INE's mission to provide the scientific basis for assessing long-term safety of a final nuclear waste repository. The INE-Beamline is accessible for the actinide and radiochemistry community through the ANKA proposal system and the European Union Integrated Infrastructure Initiative ACTINET-I3. Experiments with activities up to 1 × 10+6 times the European exemption limit are feasible within a safe but flexible containment concept. Measurements with monochromatic radiation are performed at photon energies varying between ˜2.1 keV (P K-edge) and ˜25 keV (Pd K-edge), including the lanthanide L-edges and the actinide M- and L3-edges up to Cf. The close proximity of the INE-Beamline to INE controlled area labs offers infrastructure unique in Europe for the spectroscopic and microscopic characterization of actinide samples. The modular beamline design enables sufficient flexibility to adapt sample environments and detection systems to many scientific questions. The well-established bulk techniques x-ray absorption fine structure (XAFS) spectroscopy in transmission and fluorescence mode have been augmented by advanced methods using a microfocused beam, including (confocal) XAFS/x-ray fluorescence detection and a combination of (micro-)XAFS and (micro-)x-ray diffraction. Additional instrumentation for high energy-resolution x-ray emission spectroscopy has been successfully developed and tested.

  2. The INE-Beamline for actinide science at ANKA

    International Nuclear Information System (INIS)

    Rothe, J.; Dardenne, K.; Denecke, M. A.; Kienzler, B.; Loeble, M.; Metz, V.; Steppert, M.; Vitova, T.; Geckeis, H.; Butorin, S.; Seibert, A.; Walther, C.

    2012-01-01

    Since its inauguration in 2005, the INE-Beamline for actinide research at the synchrotron source ANKA (KIT North Campus) provides dedicated instrumentation for x-ray spectroscopic characterization of actinide samples and other radioactive materials. R and D work at the beamline focuses on various aspects of nuclear waste disposal within INE's mission to provide the scientific basis for assessing long-term safety of a final nuclear waste repository. The INE-Beamline is accessible for the actinide and radiochemistry community through the ANKA proposal system and the European Union Integrated Infrastructure Initiative ACTINET-I3. Experiments with activities up to 1 x 10 +6 times the European exemption limit are feasible within a safe but flexible containment concept. Measurements with monochromatic radiation are performed at photon energies varying between ∼2.1 keV (P K-edge) and ∼25 keV (Pd K-edge), including the lanthanide L-edges and the actinide M- and L3-edges up to Cf. The close proximity of the INE-Beamline to INE controlled area labs offers infrastructure unique in Europe for the spectroscopic and microscopic characterization of actinide samples. The modular beamline design enables sufficient flexibility to adapt sample environments and detection systems to many scientific questions. The well-established bulk techniques x-ray absorption fine structure (XAFS) spectroscopy in transmission and fluorescence mode have been augmented by advanced methods using a microfocused beam, including (confocal) XAFS/x-ray fluorescence detection and a combination of (micro-)XAFS and (micro-)x-ray diffraction. Additional instrumentation for high energy-resolution x-ray emission spectroscopy has been successfully developed and tested.

  3. Evaluation of the transmitted exposure through lead equivalent aprons used in a radiology department, including the contribution from backscatter

    International Nuclear Information System (INIS)

    Christodoulou, Emmanuel G.; Goodsitt, Mitchell M.; Larson, Sandra C.; Darner, Katie L.; Satti, Jahangir; Chan, H.-P.

    2003-01-01

    A study was conducted to evaluate the radiation transmission through lead equivalent aprons that are used in a radiology department. A large area beam (poor geometry) was employed for the transmission measurements, and backscatter was simulated by placing 7 '' of Lucite behind each apron. Separate ionization chambers were used to measure the incident and transmitted x-ray beams. Transmission measurements were made at 70 kVp and 100 kVp through aprons and protective shields from eight different vendors that were marked 0.25 mm and 0.5 mm lead equivalent. Transmissions through 0.254 mm and 0.508 mm of pure lead were also measured and were compared with the transmissions through the lead equivalent materials. In addition, the area densities of the aprons were measured to compare radiation transmission with respect to the weights of the aprons. At 70 kVp, the transmission through 0.254 mm of pure lead was 5.4% and the transmissions through the 0.25 mm lead equivalent materials were 4.3% to 10.2% with a mean value of 7.1% and a standard deviation (s.d.) of 1.4%. At 100 kVp, the values were 15% for 0.254 mm pure lead and 12.3% to 20.7% (mean 16.8%, s.d. 2.1%) for the 0.25 mm lead equivalent materials. The transmission through the 0.508 mm pure lead sample was 0.9% at 70 kVp, and the corresponding transmissions through the 0.5 mm lead equivalent materials were 0.6% to 1.6% (mean 1.0%, s.d. 0.2%). At 100 kVp, the transmission through the 0.508 mm lead sample was 5% and those through the 0.5 mm lead equivalent materials were 3.5% to 6.7% (mean 4.9%, s.d. 0.7%). The radiation transmissions at 70 kVp, through two 'lead-free' 0.5 mm lead equivalent aprons, were 1.7% and 1.9% and at 100 kVp the transmissions were 6.1% and 6.8%, respectively. This study indicates that there is a need to establish methods for acceptance testing of aprons and a need to establish acceptance limits for the x-ray transmission of aprons at specific kVp values. There is also a need for the

  4. Microcystin-LR equivalent concentrations in fish tissue during a postbloom Microcystis exposure in Loskop Dam, South Africa

    CSIR Research Space (South Africa)

    Nchabeleng, T

    2014-12-01

    Full Text Available The effects of a decomposing cyanobacteria bloom on water quality and the accumulation of microcystin-LR equivalent toxin in fish at Loskop Dam were studied in May 2012. Enzyme-linked immunosorbent assay [ELISA] was used to confirm the presence...

  5. Analisis Semiotik Fashion Ines Ariani Sebagai Bentuk Presentasi Diri

    Directory of Open Access Journals (Sweden)

    Monica Stella Angelina

    2015-12-01

    Full Text Available Fashion can be seen from the side semoitikanya that denotation and connotation. Like the black color that has connotations mysterious, bold, independent, and stylish, yellow color that symbolizes joy and a sense of spirit. Tiger spotted pattern connotes bold. Clothes that show the shape of the body shape connotes the online, open-minded, and confident. Denotation and connotation of this it can be concluded that Ines presenting himself as someone who is brave, open, cheerful, and stylish. Fashion and clothing are included in it has a deeper function than as body armor and kesopan that as the way a person communicates where fashion clothing is non-verbal communication that is artifactual. It can be seen that one can judge others simply on appearances alone. Even generally someone will first see the appearance of others before making conversation. This conversation function to verify whether the accepted meaning when just looking at clothes only in accordance with the meaning of a conversation or when it is doing the opposite. Although a person can wear to present themselves as it is, but nonetheless in reality there is an element of performance in it. It is also likely to be experienced by Ines, where in addition wants to present himself, Ines also wants the fashion that he was wearing viewed and became the center of attention of the crowd. Fashion dapat dilihat secara semoitikanya yaitu dari sisi denotasi dan konotasinya. Seperti warna hitam yang memiliki konotasi misterius, berani, mandiri, dan stylish, warna kuning yang melambangkan keceriaan dan rasa semangat. Pattern totol harimau yang berkonotasi berani. Bentuk pakaian yang memperlihatkan bentuk tubuh berkonotasi daring, open-minded, dan percaya diri. Dari denotasi dan konotasi inilah dapat diambil kesimpulan bahwa Ines mempresentasikan dirinya sebagai seseorang yang berani, terbuka, ceria, dan stylish. Fashion dan pakaian yang termasuk di dalamnya memiliki fungsi yang lebih mendalam selain

  6. Expression of proliferative and inflammatory markers in a full-thickness human skin equivalent following exposure to the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide

    International Nuclear Information System (INIS)

    Black, Adrienne T.; Hayden, Patrick J.; Casillas, Robert P.; Heck, Diane E.; Gerecke, Donald R.; Sinko, Patrick J.; Laskin, Debra L.; Laskin, Jeffrey D.

    2010-01-01

    Sulfur mustard is a potent vesicant that induces inflammation, edema and blistering following dermal exposure. To assess molecular mechanisms mediating these responses, we analyzed the effects of the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide, on EpiDerm-FT TM , a commercially available full-thickness human skin equivalent. CEES (100-1000 μM) caused a concentration-dependent increase in pyknotic nuclei and vacuolization in basal keratinocytes; at high concentrations (300-1000 μM), CEES also disrupted keratin filament architecture in the stratum corneum. This was associated with time-dependent increases in expression of proliferating cell nuclear antigen, a marker of cell proliferation, and poly(ADP-ribose) polymerase (PARP) and phosphorylated histone H2AX, markers of DNA damage. Concentration- and time-dependent increases in mRNA and protein expression of eicosanoid biosynthetic enzymes including COX-2, 5-lipoxygenase, microsomal PGE 2 synthases, leukotriene (LT) A 4 hydrolase and LTC 4 synthase were observed in CEES-treated skin equivalents, as well as in antioxidant enzymes, glutathione S-transferases A1-2 (GSTA1-2), GSTA3 and GSTA4. These data demonstrate that CEES induces rapid cellular damage, cytotoxicity and inflammation in full-thickness skin equivalents. These effects are similar to human responses to vesicants in vivo and suggest that the full thickness skin equivalent is a useful in vitro model to characterize the biological effects of mustards and to develop potential therapeutics.

  7. The International Nuclear Event Scale (INES) user's manual. 2001 edition; La escala internacional de sucesos nucleares (INES) manual del usuario. Edicion de 2001

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-12-01

    The International Nuclear Event Scale (INES) was introduced in March 1990 jointly by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development (OECD/NEA). Its primary purpose is to facilitate communication and understanding between the nuclear community, the media and the public on the safety significance of events occurring at nuclear installations. The scale was refined in 1992 in the light of experience gained and extended to be applicable to any event associated with radioactive material and/or radiation, including the transport of radioactive materials.This edition of the INES User's Manual incorporates experience gained from applying the 1992 version of the scale and the document entitled 'Clarification of Issues Raised'. As such, it replaces those earlier publications. It does not amend the technical basis of the INES rating procedure but is expected to facilitate the task of those who are required to rate the safety significance of events using the INES scale. The INES communication network currently receives and disseminates event information to the INES National Officers of 60 Member States on special Event Rating Forms which represent official information on the events, including the rating. The INES communication process has led each participating country to set up an internal network which ensures that all events are promptly communicated and rated whenever they have to be reported outside or inside the country. The IAEA provides training services on the use of INES on request.

  8. The International Nuclear and Radiological Event Scale (INES): 20 Years of Nuclear Communication

    International Nuclear Information System (INIS)

    2010-01-01

    Full text: Today, the International Atomic Energy Agency (IAEA) and the OECD Nuclear Energy Agency (NEA) are celebrating the 20th anniversary of the International Nuclear and Radiological Event Scale (INES). Jointly developed by the IAEA and the NEA in 1990, in the aftermath of the Chernobyl accident, the purpose of INES is to help nuclear and radiation safety authorities and the nuclear industry worldwide to rate nuclear and radiological events and to communicate their safety significance to the general public, the media and the technical community. INES has often been compared to other scales used to measure physical properties such as temperature - the Celsius, Kelvin or Fahrenheit scales - or rate events such as earthquakes - the Richter scale. Like these scales, INES also has a sound technical background and can be easily understood. INES was initially used to classify events at nuclear power plants only. It was subsequently extended to rate events occurring in any nuclear facility and during the transport of radioactive material, thus also covering events related to the overexposure of workers. Since 2008, INES has been extended to any event associated with the transport, storage and use of radioactive material and radiation sources, from those occurring at nuclear facilities to those associated with industrial use. More generally, INES has also become a crucial nuclear communications tool. Since its inception, it has been adopted in 69 countries, and an increasing number of countries have expressed their interest in using INES and have designated INES national officers. Over the years, national nuclear safety authorities have made growing use of INES, while the public and the media have become more familiar with the scale and its significance. This is where the true success of INES stands, having helped to foster transparency and provide a better understanding of nuclear-related events and activities. For a full description of the International Nuclear and

  9. Common Risk Target for severe accidents of nuclear power plants based on IAEA INES scale

    International Nuclear Information System (INIS)

    Vitázková, Jiřina; Cazzoli, Errico

    2013-01-01

    original idea is used to join PSA L2 analyses with IAEA INES scale expressed in I 131 equivalent transformed to consequences. The INES scale became the basis for further considerations as it is currently used for evaluation of degree of severity of real accidents. Since PSA deals with potential accidents which might become real with some probability (therefore PSAs are performed indeed), the INES scale seems to be a good tool – commonly and widely accepted for real accidents – to evaluate the degree of severity of potential accidents and thus to be used for the risk limit/target definition for nuclear accidents

  10. Common Risk Target for severe accidents of nuclear power plants based on IAEA INES scale

    Energy Technology Data Exchange (ETDEWEB)

    Vitázková, Jiřina, E-mail: jirina@snus.sk [Vitázková-Vitty, Sládkovičova 24, 900 28 Ivanka pri Dunaji (Slovakia); Cazzoli, Errico, E-mail: erik.cazzoli@gmx.net [Cazzoli Consulting, Wiesenweg 14, CH-5415 Nussbaumen (Switzerland)

    2013-09-15

    original idea is used to join PSA L2 analyses with IAEA INES scale expressed in I{sub 131} equivalent transformed to consequences. The INES scale became the basis for further considerations as it is currently used for evaluation of degree of severity of real accidents. Since PSA deals with potential accidents which might become real with some probability (therefore PSAs are performed indeed), the INES scale seems to be a good tool – commonly and widely accepted for real accidents – to evaluate the degree of severity of potential accidents and thus to be used for the risk limit/target definition for nuclear accidents.

  11. MUTZ-3 derived Langerhans cells in human skin equivalents show differential migration and phenotypic plasticity after allergen or irritant exposure

    NARCIS (Netherlands)

    Kosten, I.J.; Spiekstra, S.W.; de Gruijl, T.D.; Gibbs, S.

    2015-01-01

    After allergen or irritant exposure, Langerhans cells (LC) undergo phenotypic changes and exit the epidermis. In this study we describe the unique ability of MUTZ-3 derived Langerhans cells (MUTZ-LC) to display similar phenotypic plasticity as their primary counterparts when incorporated into a

  12. Equivalent Lagrangians

    International Nuclear Information System (INIS)

    Hojman, S.

    1982-01-01

    We present a review of the inverse problem of the Calculus of Variations, emphasizing the ambiguities which appear due to the existence of equivalent Lagrangians for a given classical system. In particular, we analyze the properties of equivalent Lagrangians in the multidimensional case, we study the conditions for the existence of a variational principle for (second as well as first order) equations of motion and their solutions, we consider the inverse problem of the Calculus of Variations for singular systems, we state the ambiguities which emerge in the relationship between symmetries and conserved quantities in the case of equivalent Lagrangians, we discuss the problems which appear in trying to quantize classical systems which have different equivalent Lagrangians, we describe the situation which arises in the study of equivalent Lagrangians in field theory and finally, we present some unsolved problems and discussion topics related to the content of this article. (author)

  13. Low-level human equivalent gestational lead exposure produces sex-specific motor and coordination abnormalities and late-onset obesity in year-old mice.

    Science.gov (United States)

    Leasure, J Leigh; Giddabasappa, Anand; Chaney, Shawntay; Johnson, Jerry E; Pothakos, Konstantinos; Lau, Yuen Sum; Fox, Donald A

    2008-03-01

    Low-level developmental lead exposure is linked to cognitive and neurological disorders in children. However, the long-term effects of gestational lead exposure (GLE) have received little attention. Our goals were to establish a murine model of human equivalent GLE and to determine dose-response effects on body weight, motor functions, and dopamine neurochemistry in year-old offspring. We exposed female C57BL/6 mice to water containing 0, 27 (low), 55 (moderate), or 109 ppm (high) of lead from 2 weeks prior to mating, throughout gestation, and until postnatal day 10 (PN10). Maternal and litter measures, blood lead concentrations ([BPb]), and body weights were obtained throughout the experiment. Locomotor behavior in the absence and presence of amphetamine, running wheel activity, rotarod test, and dopamine utilization were examined in year-old mice. Peak [BPb] were obesity. Similarly, we observed male-specific decreased spontaneous motor activity, increased amphetamine-induced motor activity, and decreased rotarod performance in year-old GLE mice. Levels of dopamine and its major metabolite were altered in year-old male mice, although only forebrain utilization increased. GLE-induced alterations were consistently larger in low-dose GLE mice. Our novel results show that GLE produced permanent male-specific deficits. The nonmonotonic dose-dependent responses showed that low-level GLE produced the most adverse effects. These data reinforce the idea that lifetime measures of dose-response toxicant exposure should be a component of the neurotoxic risk assessment process.

  14. Acute non-stochastic effect of very low dose whole-body exposure, a thymidine equivalent serum factor

    International Nuclear Information System (INIS)

    Feinendegen, L.E.; Muehlensiepen, H.; Porschen, W.; Booz, J.

    1982-01-01

    Whole-body irradiation of mice causes the dose-dependent appearance of a humoral factor in blood serum which inhibits incorporation of 125-IUdR into tissue culture cells. This factor appears even at doses below 0.01 Gy gamma irradiation and thus is probably not related to cell death. Data are presented relating this humoral factor to thymidine. Since at low doses the target size for this effect was calculated to be the entire cell, a cellular effect is postulated linking the site of few primary absorption events, anywhere in the cell, with the cellular membrane, thus causing changes in membrane charge, structure and/or fluidity. This may lead to blocking thymidine acceptance by the cell, and thus would cause a pile-up of thymidine in the reutilization pathway in peripheral blood and would give rise to the observed effect. The effect appears as a temporary disturbance of the physiological equilibrium and should not be related at present to any cellular damage. The acute low-dose effect described has implications for the measurement of low-dose exposure by biological dosimeters and on basic research on membrane function. (author)

  15. Report of the 1995 annual meeting of INES national officers. Experience and feedback from operation of the INES information service

    International Nuclear Information System (INIS)

    1995-01-01

    Fifty-eight countries are now formally participating in the use of INES as a means of prompt communication of nuclear events. Twenty-six countries attended the TCM, including nearly all countries with major nuclear programmes. Presentations were given by all attendees. No events above level 2 were reported in 1994/95. Participants reported that the use of the Scale was proceeding satisfactorily in their countries without major problems. In some countries, notable progress had been made in obtaining greater understanding and use of the Scale by the media and public. However, it was recognized that communication issues remain of the highest priority. Refs, figs, tabs

  16. Report of the 1995 annual meeting of INES national officers. Experience and feedback from operation of the INES information service

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    Fifty-eight countries are now formally participating in the use of INES as a means of prompt communication of nuclear events. Twenty-six countries attended the TCM, including nearly all countries with major nuclear programmes. Presentations were given by all attendees. No events above level 2 were reported in 1994/95. Participants reported that the use of the Scale was proceeding satisfactorily in their countries without major problems. In some countries, notable progress had been made in obtaining greater understanding and use of the Scale by the media and public. However, it was recognized that communication issues remain of the highest priority. Refs, figs, tabs.

  17. Experience of the South African regulatory authority in the use of INES

    International Nuclear Information System (INIS)

    Henderson, N.R.

    1997-01-01

    The INES National Officer for South Africa who is employed by the Council for Nuclear Safety (CNS), briefly presents the INES situation with other licensees of the CNS, namely the Atomic Energy Corporation (AEC) and various mining and minerals processing facilities

  18. Association between homocyst(e)ine levels and risk of vascular events.

    Science.gov (United States)

    Kaplan, Eugene D

    2003-03-01

    Homocyst(e)ine is a novel risk factor in vascular disease. First observations of vascular lesions in children with high blood homocyst(e)ine levels due to severe inborn enzyme deficiencies led to the hypothesis that elevated blood homocyst(e)ine levels might be a risk factor for vascular disease. A substantial body of evidence on the role of the homocyst(e)ine in the development of coronary and carotid artery disease, myocardial infarction, stroke, deep vein thrombosis and other disorders has been accumulated over the last 30 years. Cross-sectional and case-control studies provide initial and the strongest support for the hypothesis, followed by results from the prospective cohorts. Infrequent cases of homozygous mutations of the key enzymes in the homocyst(e)ine metabolism chain are able to produce extreme homocyst(e)inemia and early vascular lesions. More frequently, heterozygous enzyme mutations and deficiencies of folate and vitamins B6 and B12 cause mild to moderate homocyst(e)inemia, which is still strongly associated with the increased risk of vascular events. Elevated homocyst(e)ine levels may be effectively managed with adequate folate, B12 and B6 intake in doses comparable to or above FDA recommendations. Whether correction of elevated homocyst(e)ine levels with vitamins is helpful in prevention and treatment of vascular events remains unknown and is under investigation in ongoing clinical trials (VISP, VITATOPS). No consensus on homocyst(e)ine management is available at the present time.

  19. Pollutant emission registers-INES and EPER toward PRTR

    International Nuclear Information System (INIS)

    Caricchia, A.M.; Cirillo, M.C.; Gagna, A.

    2005-01-01

    PRTRs (Pollutant Release and Transfer Registers) are information systems collecting and providing public access to information on pollutant releases in the environment. These registers are based on a scheduled reporting by the manufacturing facilities. Since the establishment of the TRI (Toxic Release lnventory) at the end of the '80s in the USA, international interest grew focussing on the definition of the features of national PRTRs as environmental management systems. The Protocol on PRTRs, the first international legally binding agreement, was signed in 2003 in the frame of the UNECE-Convention on Access to Information, Public Participation in Decision-making and Access to Justice in Environmental Matters (Aarhus Convention, 1999). The European register EPER (European Pollutant Emission Register), established in the Directive 96/61/EC, represents the first step at a European level towards a truly integrated pollutant emissions register, an experience which is going to improve further with the forthcoming introduction of the E-PRTR (European Pollutant Release and Transfer Register). Operating since 2003, EPER collects the information provided by 9377 facilities spread over EU15 countries plus Norway and Hungary. Concerning Italy, in accordance with European EPER, a national pollutant emission register has been established, called INES ('Inventario Nazionale delle Emissioni e loro Sorgenti'). INES can be currently browsed and queried on the following web-page: http://www.sinanet.apat.it [it

  20. Vitamin intake: a possible determinant of plasma homocyst(e)ine among middle-aged adults.

    Science.gov (United States)

    Shimakawa, T; Nieto, F J; Malinow, M R; Chambless, L E; Schreiner, P J; Szklo, M

    1997-05-01

    Many epidemiologic studies have identified elevated plasma homocyst(e)ine as a risk factor for atherosclerosis and thromboembolic disease. To examined the relationship between vitamin intakes and plasma homocyst(e)ine, we analyzed dietary intake data from a case-control study of 322 middle-aged individuals with atherosclerosis in the carotid artery and 318 control subjects without evidence of this disease. All of these individuals were selected from a probability sample of 15,800 men and women who participated in the Atherosclerosis Risk in Communities (ARIC) Study. Plasma homocyst(e)ine was inversely associated with intakes of folate, vitamin B6, and vitamin B12 (controls only for this vitamin)--the three key vitamins in homocyst(e)ine metabolism. Among nonusers of vitamin supplement products, on average each tertile increase in intake of these vitamins was associated with 0.4 to 0.7 mumol/L decrease in plasma homocyst(e)ine. An inverse association of plasma homocyst(e)ine was also found with thiamin, riboflavin, calcium, phosphorus, and iron. Methionine and protein intake did not show any significant association with plasma homocyst(e)ine. In almost all analyses, cases and controls showed similar associations between dietary variables and plasma homocyst(e)ine. Plasma homocyst(e)ine among users of vitamin supplement products was 1.5 mumol/L lower than that among nonusers. Further studies to examine possible causal relationships among vitamin intake, plasma homocyst(e)ine, and cardiovascular disease are needed.

  1. Elevated second-trimester serum homocyst(e)ine levels and subsequent risk of preeclampsia.

    Science.gov (United States)

    Sorensen, T K; Malinow, M R; Williams, M A; King, I B; Luthy, D A

    1999-01-01

    Elevated plasma homocyst(e)ine is a risk factor for endothelial dysfunction and vascular disease. In late gestation, levels of homocyst(e)ine are higher in preeclamptics, as compared with normotensive pregnant women. Our objective was to determine whether homocyst(e)ine elevations precede the development of preeclampsia. We used a prospective nested case-control study design to compare second trimester maternal serum homocyst(e)ine concentrations in 52 patients who developed preeclampsia (pregnancy-induced hypertension with proteinuria) compared with 56 women who remained normotensive throughout pregnancy. Study subjects were selected from a base population of 3, 042 women who provided blood samples at an average gestational age of 16 weeks and later delivered at our center. Serum homocyst(e)ine was measured by high-performance liquid chromatography and electrochemical detection. Approximately 29% of preeclamptics, as compared to 13% of controls had homocyst(e)ine levels >/=5.5 micromol/l (upper decile of distribution of control values). Adjusted for maternal age, parity, and body mass-index, a second trimester elevation of homocyst(e)ine was associated with a 3. 2-fold increased risk of preeclampsia (adjusted OR = 3.2; 95% CI 1. 1-9.2; p = 0.030). There was evidence of a interaction between maternal adiposity (as indicated by her prepregnancy body mass index) and parity with second trimester elevations in serum homocyst(e)ine. Nulliparous women with elevated homocyst(e)ine levels experienced a 9.7-fold increased risk of preeclampsia as compared with multiparous women without homocyst(e)ine elevations (95% CI 2.1-14.1; p = 0.003). Women with a higher prepregnancy body mass index (>/=21.4 kg/m(2), or upper 50th percentile) and who also had elevated homocyst(e)ine levels, as compared with leaner women without homocyst(e)ine elevations were 6.9 times more likely to later develop preeclampsia (95% CI 1.4-32.1; p = 0.016). Our findings are consistent with other

  2. INES: The International Nuclear Event Scale. User's manual

    International Nuclear Information System (INIS)

    1990-08-01

    The International Nuclear Event Scale (INES) is being introduced for a trial period, the primary purpose being to facilitate communication between the nuclear community, the media and the public on such events. The scale runs from zero, for events with no safety significance, to seven for a major accident. The scale has been circulated to Member States of the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development and it is presently anticipated that the trial period will last until late 1991. Provision has been made for the scale to be refined thereafter in the light of experience. It is designed as an important tool in providing prompt, clear and consistent information on nuclear events wherever and whenever they may occur. 2 figs, 2 tabs

  3. Experience in the Application of INES scale to events in the Spanish Radioactive facilities

    International Nuclear Information System (INIS)

    Ramirez, M. L.; Alvarez, C.

    2002-01-01

    In February 2001, the International Atomic Energy Agency (IAEA) and the Nuclear energy Agency of the OECD (NEA) published a new edition of the INES User's Manual for the classification of nuclear events. One of the new developments introduced with respect to the scope of the former Manual was the inclusion within the INES of any event associated with radioactive material and/or radiation. This would include events occurred in radioactive facilities so the INES would apply not only to events in nuclear facilities. During the publication process some doubts rose about the applicability of INES to other non nuclear types of events. The IAEA was open to the future development of more practical guidance for the application of the scale. Since the beginning of 2001 the Consejo de Seguridad Nuclear (CSN) has been using INES to test the applicability of the system to classify events in radioactive facilities. A total of 31 events occurred at Spanish radioactive facilities has been classified applying INES scale and a report was sent to IAEA to publish our experience. The objective of this presentation is to introduce the experience obtained by the application of the International Nuclear Events Scale (INES) to classify events in radioactive facilities in Spain and to present several issues raised during its application that may need further development in a practical guidance. (Author)

  4. Cyst(e)ine requirements in enterally fed very low birth weight preterm infants.

    Science.gov (United States)

    Riedijk, Maaike A; Voortman, Gardi; van Beek, Ron H T; Baartmans, Martin G A; Wafelman, Leontien S; van Goudoever, Johannes B

    2008-03-01

    Optimal nutrition is of utmost importance for the preterm infant's later health and developmental outcome. Amino acid requirements for preterm infants differ from those for term and older infants, because growth rates differ. Some nonessential amino acids, however, cannot be sufficiently synthesized endogenously. Cyst(e)ine is supposed to be such a conditionally essential amino acid in preterm infants. The objective of this study was to determine, at 32 and 35 weeks' postmenstrual age, cyst(e)ine requirements in fully enterally fed very low birth weight preterm infants with gestational ages of ine requirement was determined with the indicator amino acid oxidation technique ([1-(13)C]phenylalanine) after 24-hour adaptation. Fractional [1-(13)C]phenylalanine oxidation was established in 47 very low birth weight preterm infants (mean gestational age: 28 weeks +/- 1 week SD; birth weight: 1.07 kg +/- 0.21 kg SD). Increase in dietary cyst(e)ine intake did not result in a decrease in fractional [1-(13)C]phenylalanine oxidation. These data do not support the hypothesis that endogenous cyst(e)ine synthesis is limited in very low birth weight preterm infants with gestational ages of ine requirement is ine is probably not a conditionally essential amino acid in these infants.

  5. Plasma homocyst(e)ine concentrations in pregnant and nonpregnant women with controlled folate intake.

    Science.gov (United States)

    Bonnette, R E; Caudill, M A; Boddie, A M; Hutson, A D; Kauwell, G P; Bailey, L B

    1998-08-01

    To assess the effects of folate intake and pregnancy on plasma total homocyst(e)ine concentrations in women during the second trimester of pregnancy compared with young, healthy nonpregnant women. The diet provided either 450 or 850 microg of folate per day. These levels are approximately the current (400 microg/day) and previous (800 microg/day) Recommended Dietary Allowances for folate in pregnant women. Folate was provided as both food folate (120 microg/day) and supplemental folic acid (either 330 or 730 microg/day) for a period of 12 weeks. Plasma homocyst(e)ine (sum of free and protein-bound homocysteine), serum folate, and erythrocyte folate concentrations were determined weekly. Homocyst(e)ine concentrations were lower in pregnant women during the second trimester of normal pregnancy than in nonpregnant controls, independent of dietary folate intake. The overall mean (+/- standard deviation) homocyst(e)ine concentration of the pregnant subjects (5.4 +/- 1.4 micromol/L) was significantly lower than that observed in the nonpregnant control group (8.7 +/- 1.7 micromol/L) (P ine concentrations remained constant throughout the 12 weeks of the investigation. The folate intakes in this investigation were adequate to maintain constant homocyst(e)ine concentrations in pregnant and nonpregnant women. The lower homocyst(e)ine concentrations observed in pregnant subjects compared with nonpregnant controls may be a physiologic response to pregnancy.

  6. Patients with atherosclerotic vascular disease: how low should plasma homocyst(e)ine levels go?

    Science.gov (United States)

    Spence, J D

    2001-01-01

    Plasma homocyst(e)ine level is a strong independent risk factor for vascular disease. The spelling of homocyst(e)ine reflects that what is measured, and what constitutes the risk factor; it includes homocysteine, homocystine (the dimer of homocysteine) and mixed cysteine-homocysteine disulfide. Homocyst(e)ine levels above 10.2 micro mol/L are associated with a doubling of coronary risk, and levels above 20 micro mol/L are associated with a 9.9-fold increase in risk compared with levels below 9 micro mol/L. The mechanisms by which homocyst(e)ine promotes vascular disease include increased thrombosis, consumption of nitric oxide, endothelial injury, and reduced thrombolysis. Homocyst(e)ine is an independent predictor of carotid atherosclerosis. Vitamin therapy with folate, pyridoxine (vitamin B(6)), and cyanocobalamin (vitamin B(12)) reduces blood levels of homocyst(e)ine, improves endothelial function, reduces levels of fibrinogen and lipoprotein(a), improves thrombolysis, and in uncontrolled clinical observation, leads to regression of carotid plaque. These lines of evidence support a causal relationship between homocyst(e)ine and atherosclerosis, and suggest that in patients with vascular disease, an appropriate target level for therapy may be below 9 or 10 micro mol/L. Randomized controlled studies are under way to determine whether vitamin therapy is effective in secondary prevention of myocardial infarction and stroke.

  7. Homocyst(e)ine and atherosclerosis in patients on chronic hemodialysis.

    Science.gov (United States)

    Lee, Y K; Kwon, Y J; Yoon, J W; Oh, K S; Cha, D R; Cho, W Y; Huh, K; Pyo, H J; Kim, H K

    1999-04-01

    Hyperhomocyst(e)inemia is an established risk factor for atherosclerosis. We performed this study to identify the correlating variables and risk factors for atherosclerosis, as measured by the atherosclerotic score (AS), and to determine the relative risk for cardiovascular disease in relation to plasma homocyst(e)ine levels in patients on chronic hemodialysis. We evaluated and measured 61 patients on chronic hemodialysis for clinical and biochemical parameters including atherosclerotic score (AS) and plasma homocyst(e)ine. We divided patients into high and low groups, first, by the mean AS, and second, by the median value of plasma total homocyst(e)ine levels. Then we compared the variables between the two groups. Out of the 61 patients, the median plasma total homocyst(e)ine level was 24.4 micromol/L (mean+/-SD, 27.7+/-17.4; range, 9.8-127.4 micromol/L), and the median AS was 5 (mean+/-SD, 6.2+/-2.8; range, 3-13) out of a possible 20 points. AS was significantly correlated with plasma total homocyst(e)ine levels (r=0.37) and age (r=0.67). Through multivariate analysis, plasma total homocyst(e)ine level and age were determined as significant risk factors for the high-AS group (pine level did not correlate with age (p>0.05). Eighteen of the 61 patients, presented with cardiovascular disease until the present study, had an AS>6. Cardiovascular disease was found more often in the high-homocyst(e)ine group (>24.4 micromol/L) than in the low-homocyst(e)ine group (odds ratio, 9.3; 95% confidence interval, 2.3-37.4). Regardless of age, hyperhomocyst(e)inemia (especially homocyst(e)ine levels >24.4 micromol/L) is a risk factor that can be modified for the development of cardiovascular disease in patients on chronic hemodialysis.

  8. Event classification related to overflow of solvent containing uranium according to the INES scale (International Nuclear and Radiological Event Scale); Classificacao do evento de transbordamento de solvente contendo uranio segundo a escala INES (International Nuclear and Radiological Event Scale)

    Energy Technology Data Exchange (ETDEWEB)

    Dourado, Eneida R.G.; Assis, Juliana T. de; Lage, Ricardo F., E-mail: cneida@inb.gov.br, E-mail: julianateixeira@inb.gov.br, E-mail: rlage@inb.gov.br [lndustrias Nucleares do Brasil S/A (CLISE.P/INB), Rio de Janeiro, RJ (Brazil). Coordenacao de Licenciamento Nuclear e Ambiental, Saude e Seguranca; Lopes, Karina B., E-mail: karina@inb.gov.br [lndustrias Nucleares do Brasil S/A (CPRAD/INB), Rio de Janeiro, RJ (Brazil). Coordenacao de Protecao Radiologica

    2013-11-01

    This paper aims to frame the event overflow organic solvent rich in uranium, from a decanter of ore beneficiation plant, caused by the fall in the supply of electricity, according to the criteria established by the International Nuclear Event Scale and radiological (INES), facilitating the understanding of the occurrence and communication with the public regarding the radiation safety aspects involved. With the fall of electricity, routine procedures in situations of installation stop were performed, however, due to operational failure, the valve on the transfer line liquor was not closed. Thus, the mixer continued being fed with liquor, that led the consequent leakage of solvent loaded with uranium. It reached the drainage system, and the box of rainwater harvesting of the plant. However, immediately after the detection of the event, corrective actions were initiated and the overflow was contained. Regulatory agencies followed the removal of the solvent and on the results of the analysis of environmental monitoring, found that the event did not provide exposure to workers or any other impact. Therefore, comparing the characteristics of the event and the guidelines proposed by the INES scale, it is concluded that the classification of the event is below scale/level 0, confirming the absence of risk to the local population, workers and the environment.

  9. Event classification related to overflow of solvent containing uranium according to the INES scale (International Nuclear and Radiological Event Scale)

    International Nuclear Information System (INIS)

    Dourado, Eneida R.G.; Assis, Juliana T. de; Lage, Ricardo F.; Lopes, Karina B.

    2013-01-01

    This paper aims to frame the event overflow organic solvent rich in uranium, from a decanter of ore beneficiation plant, caused by the fall in the supply of electricity, according to the criteria established by the International Nuclear Event Scale and radiological (INES), facilitating the understanding of the occurrence and communication with the public regarding the radiation safety aspects involved. With the fall of electricity, routine procedures in situations of installation stop were performed, however, due to operational failure, the valve on the transfer line liquor was not closed. Thus, the mixer continued being fed with liquor, that led the consequent leakage of solvent loaded with uranium. It reached the drainage system, and the box of rainwater harvesting of the plant. However, immediately after the detection of the event, corrective actions were initiated and the overflow was contained. Regulatory agencies followed the removal of the solvent and on the results of the analysis of environmental monitoring, found that the event did not provide exposure to workers or any other impact. Therefore, comparing the characteristics of the event and the guidelines proposed by the INES scale, it is concluded that the classification of the event is below scale/level 0, confirming the absence of risk to the local population, workers and the environment

  10. Rating of transport and radiation source events. Draft additional guidance for the INES national officers for pilot use and feedback; Echelle de classement des incidents de radioprotection: document d'application du systeme international propose par l'AIEA pour les sources radioactives et les transports

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-09-15

    The International Nuclear Event Scale (INES) is a means for promptly communicating to the public in consistent terms the safety significance of any reported event associated with radioactive material and/or radiation and to any event occurring during the transport of radioactive material. As described in the 2001 Edition of the INES User.s Manual, events are classified on the scale at seven levels: the upper levels (4-7) are termed accidents. and the lower levels (1-3) incidents. Events which have no safety significance are classified below scale at Level 0 and termed deviations. An overview of the principles for the rating under INES together with flow charts summarizing the rating process is provided in Appendix I. The 2001 Edition of the INES User.s Manual provides some guidance for the rating of transport and radiation source events. At the technical meeting held in 2002 the INES National Officers requested the IAEA/NEA Secretariat to prepare additional guidance. Progress was reported at the Technical Meeting of the INES National Officers in March 2004 where preparation of this draft additional guidance was requested for pilot use. This note provides additional guidance on the rating of transport and radiation source events. It is for pilot use and feedback and is broadly consistent with the INES User.s Manual. It provides more detailed information and an expanded approach for the rating based on actual exposure of workers and members of the public. It is designed to be used as a self-standing document with limited need for reference to the INES User Manual. (author)

  11. Gyrokinetic equivalence

    International Nuclear Information System (INIS)

    Parra, Felix I; Catto, Peter J

    2009-01-01

    We compare two different derivations of the gyrokinetic equation: the Hamiltonian approach in Dubin D H E et al (1983 Phys. Fluids 26 3524) and the recursive methodology in Parra F I and Catto P J (2008 Plasma Phys. Control. Fusion 50 065014). We prove that both approaches yield the same result at least to second order in a Larmor radius over macroscopic length expansion. There are subtle differences in the definitions of some of the functions that need to be taken into account to prove the equivalence.

  12. INES: The International Nuclear and Radiological Event Scale User's Manual. 2008 Edition (Spanish Edition)

    International Nuclear Information System (INIS)

    2010-11-01

    INES, the International Nuclear and Radiological Event Scale, was developed in 1990 by experts convened by the IAEA and the OECD Nuclear Energy Agency with the aim of communicating the safety significance of events. This edition of the INES User?s Manual is designed to facilitate the task of those who are required to rate the safety significance of events using the scale. It includes additional guidance and clarifications, and provides examples and comments on the continued use of INES. With this new edition, it is anticipated that INES will be widely used by Member States and become the worldwide scale for putting into proper perspective the safety significance of any event associated with the transport, storage and use of radioactive material and radiation sources, whether or not the event occurs at a facility.

  13. INES: The International Nuclear and Radiological Event Scale User's Manual. 2008 Edition (Chinese Edition)

    International Nuclear Information System (INIS)

    2012-01-01

    INES, the International Nuclear and Radiological Event Scale, was developed in 1990 by experts convened by the IAEA and the OECD Nuclear Energy Agency with the aim of communicating the safety significance of events. This edition of the INES User's Manual is designed to facilitate the task of those who are required to rate the safety significance of events using the scale. It includes additional guidance and clarifications, and provides examples and comments on the continued use of INES. With this new edition, it is anticipated that INES will be widely used by Member States and become the worldwide scale for putting into proper perspective the safety significance of any event associated with the transport, storage and use of radioactive material and radiation sources, whether or not the event occurs at a facility.

  14. Cyst(e)ine imbalance and its effect on methionine precursor utilization in chicks.

    Science.gov (United States)

    Dilger, R N; Baker, D H

    2008-08-01

    Five 9- or 12-d chick growth bioassays were done in batteries using 2 Met-deficient diets: a purified AA-based diet containing (by analysis, as-fed) 20.3% CP, 0.12% Met, and 0.05% cyst(e)ine; and an AA-fortified corn-peanut meal diet containing (by analysis, as-fed) 19.0% CP, 0.22% Met, and 0.23% cyst(e) ine. Feed-grade DL-Met (dl-M; 99%) was compared with feed-grade DL-OH-Met, Ca (OH-M; 84%). When the purified diet was modified to contain 0.12% Met and 0.20% or greater cyst(e)ine, slope-ratio assays involving graded dosing of DL-M (0, 404, 808, and 1,212 mg of DL-M/kg) or isosulfurous levels of OH-M resulted in linear (P ine [i.e., 0.12% Met, 0.12% cyst(e)ine]. When this diet was supplemented with either 404 mg of DL-M/kg or 476 mg of OH-M/kg, BW gain and G:F responded (P 0.10). Assays 4 and 5 used the corn-peanut meal basal diet containing 0.22% total Met and 0.23% total cyst(e)ine. In both assays, addition of either 465 mg of DL-M/kg or 554 mg of OH-M/kg resulted in increased (P ine concentration. In the absence of excess cyst(e)ine, BW gain responses to DL-M and OH-M were similar, but when 0.10% excess cyst(e)ine was provided as L-cystine or feather meal, DL-M responses tended to exceed those of OH-M. Moreover, this small excess of dietary cyst(e)ine, regardless of source, depressed (P ine, when included in Met-deficient diets, has the potential to be both anorexigenic and pernicious to OH-M utilization.

  15. Compilation of INES (International Nuclear Event Scale) information. Japanese translation (Vol.2)

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Norio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-03-01

    The International Nuclear Event Scale (INES) is a means designed for providing prompt, clear and consistent information related to nuclear events, that occurred at nuclear power plants and at other nuclear facilities, and facilitating communication between the nuclear community, the media and the public on such events. The INES is jointly operated by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency of the Organization for Economic Co-operation and Development (OECD/NEA). Nuclear events reported to the INES Information System from member countries of IAEA and/or OECD/NEA are rated by the 'Scale', a consistent safety significance indicator. The scale runs from level 0, for events with no safety significance, to level 7 for a major accident with widespread health and environmental effects. The INES was introduced in March 1990 for a trial and then formally adopted in March 1992. In Japan, the INES was formally introduced in August 1992. The Japan Atomic Energy Research Institute (JAERI) has been receiving the INES information through the Science and Technology Agency, promptly translating into Japanese and providing to the relevant sections inside and outside JAERI. As well, we published the report compiling the Japanese translation of individual INES reports until May 31, 1998. Since then, we have developed a world-wide-web database for the Japanese translation and made it available to the public through the internet. This report compiles the Japanese version of approximately 70 INES reports we received from June 1, 1998 to December 31, 2000. (author)

  16. Nuclear and Radiological Event Scale Turns 20. INES Helps Authorities Rate Events and Communicate Their Significance

    International Nuclear Information System (INIS)

    Verlini, Giovanni

    2011-01-01

    Originally developed in the 1990s jointly by IAEA and Nuclear Energy Agency of the Organization for Economic Co-operation and Development (OECD/NEA) and Member States experts, INES was last revised in 2008 to become a more versatile and informative tool. INES is now designed to address events associated with the transport, storage and use of radioactive material and radiation sources, whether they occur at a nuclear installation or not.

  17. Application of the INES scale to the transport of radioactive materials

    International Nuclear Information System (INIS)

    2001-01-01

    This decision from the French authority of nuclear safety (ASN) concerns the application of the international nuclear event scale (INES) to the incidents and accidents occurring during the transport of radioactive materials. Only the off-site impacts and defense-in-depth degradation aspects are taken into account in the INES-transportation scale. A proposal of classification grid is given for both aspects. (J.S.)

  18. Plasma homocyst(e)ine concentrations in eclamptic and preeclamptic African women postpartum.

    Science.gov (United States)

    Rajkovic, A; Mahomed, K; Malinow, M R; Sorenson, T K; Woelk, G B; Williams, M A

    1999-09-01

    To examine the relationship between plasma homocyst(e)ine and risk of eclampsia and preeclampsia among sub-Saharan African women who delivered at Harare Maternity Hospital in Zimbabwe. We ran a hospital-based, case-control study at Harare Maternity Hospital, University of Zimbabwe, Harare, Zimbabwe comprising 33 pregnant women with eclampsia and 138 with preeclampsia. Controls were 185 normotensive pregnant women. Plasma was collected postpartum and homocyst(e)ine levels were measured by high-performance liquid chromatography and electrochemical detection. Women with eclampsia or preeclampsia had significantly higher mean homocyst(e)ine levels than normotensive controls (12.54 or 12.77 micromol/L versus 9.93 micromol/L, respectively, Pine distribution (median 13.9 micromol/L) compared with women in the lowest quartile (median 6.2 micromol/L). The corresponding OR for preeclampsia was 4.57. Nulliparas with elevated homocyst(e)ine had a 12.90 times higher risk of preeclampsia compared with multiparas without elevated homocyst(e)ine. Postpartum plasma homocyst(e)ine concentrations are higher among Zimbabwean women with eclampsia and preeclampsia compared with normotensive women.

  19. The Use of the International Nuclear and Radiological Event Scale (INES) for Event Communication. Guidelines and Good Practices for Setting up a National Framework on the Effective Use of INES for Event Communication

    International Nuclear Information System (INIS)

    2014-10-01

    The IAEA’s International Nuclear and Radiological Event Scale (INES) was developed in 1990 by international experts convened by the IAEA and the OECD Nuclear Energy Agency with the aim of communicating the safety significance of events at nuclear installations. Since then, INES has been expanded to meet the growing need for communicating the safety significance of events giving rise to radiation risk. At present, INES is used for communicating to the public, in a consistent way, the safety significance of an event associated with sources of radiation, whether or not the event occurs at a facility. INES covers a wide spectrum of practices, including industrial uses such as gammagraphy, the use of sources of radiation in medicine, activities at nuclear power plants and research reactors, activities at spent nuclear fuel and radioactive waste management facilities, and the transport of radioactive material. INES has become a widely used tool for putting the safety significance of radiation events into proper perspective. The number of countries using INES has risen steadily over the past five years. As a result, there is a need to ensure the harmonized application of this scale worldwide. Up to now, international activities regarding INES have focused more on developing guidance on rating events than on the ways of using INES. This publication is the first to provide guidance on establishing or improving a national framework for the effective use of INES during event communication. It has been prepared on the basis of national experience with communicating events that have occurred since the introduction of INES. This publication also includes, in Annex I, lessons learned from the application of INES during and after the accident at the Fukushima Daiichi nuclear power plant, Guidance on the Use of INES in Evolving Severe Accidents

  20. Am(m)ines make the difference: organoruthenium am(m)ine complexes and their chemistry in anticancer drug development.

    Science.gov (United States)

    Babak, Maria V; Meier, Samuel M; Legin, Anton A; Adib Razavi, Mahsa S; Roller, Alexander; Jakupec, Michael A; Keppler, Bernhard K; Hartinger, Christian G

    2013-03-25

    With the aim of systematically studying fundamental structure-activity relationships as a basis for the development of Ru(II) arene complexes (arene = p-cymene or biphenyl) bearing mono-, bi-, or tridentate am(m)ine ligands as anticancer agents, a series of ammine, ethylenediamine, and diethylenetriamine complexes were prepared by different synthetic routes. Especially the synthesis of mono-, di-, and triammine complexes was found to be highly dependent on the reaction conditions, such as stoichiometry, temperature, and time. Hydrolysis and protein-binding studies were performed to determine the reactivity of the compounds, and only those containing chlorido ligands undergo aquation or form protein adducts. These properties correlate well with in vitro tumor-inhibiting potency of the compounds. The complexes were found to be active in anticancer assays when meeting the following criteria: stability in aqueous solution and low rates of hydrolysis and binding to proteins. Therefore, the complexes least reactive to proteins were found to be the most cytotoxic in cancer cells. In general, complexes with biphenyl as arene ligand inhibited the growth of tumor cells more effectively than the cymene analogues, consistent with the increase in lipophilicity. This study highlights the importance of finding a proper balance between reactivity and stability in the development of organometallic anticancer agents. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. New developments at the INE-Beamline for actinide research at ANKA

    Science.gov (United States)

    Dardenne, K.; Brendebach, B.; Denecke, M. A.; Liu, X.; Rothe, J.; Vitova, T.

    2009-11-01

    The INE-Beamline for actinide research at the synchrotron source ANKA is operated by the Institut für Nukleare Entsorgung (INE) at the Forschungszentrum Karlsruhe. Experiments on radioactive samples with activities up to 106 times the limit of exemption inside a safe and flexible double containment concept are possible. One great advantage of the beamline is its close proximity to INE's active laboratories with its equipment for manipulation of actinide materials and state-of-the-art spectroscopic, analytical, and microscopic instrumentation. This constellation is unique in Europe. The INE-Beamline is built primarily to serve INE in-house research associated with safe disposal of high level nuclear waste such as actinide speciation or coordination-, redox-, and geo-chemistry of actinides. A wide energy range from around 2.1 keV to 25 keV covering the K-edges from P to Pd and the L3, L2, and L1 edges for actinides from Th to Cm can be used. The INE-Beamline is optimized for X-ray absorption spectroscopy techniques (XANES/EXAFS), but x-ray fluorescence (XRF) analysis and powder diffraction (XRD) are also possible, as well as surface sensitive measurements in grazing incidence geometry (GI-XAFS). Upgrades of instrumentation and extension of experimental capabilities at the INE-Beamline are driven by user needs. Two of the recent upgrades are presented: 1) installation of a microfocus option for spatially resolved studies (μ-XRF, μ-XANES, μ-XRD) and investigations of small volumes (e.g., heterogeneous natural samples and diamond anvil high pressure cells); 2) construction, and commissioning of a high resolution x-ray emission spectrometer (HRXES); 3) availability of an electrochemical cell for investigation of redox sensitive systems.

  2. Protein-bound homocyst(e)ine. A possible risk factor for coronary artery disease.

    Science.gov (United States)

    Kang, S S; Wong, P W; Cook, H Y; Norusis, M; Messer, J V

    1986-01-01

    The development of atherosclerotic changes and thromboembolism are common features in homocystinurics. Hence, we postulate a positive correlation between the level of homocyst(e)ine in the blood and the occurrence of coronary artery disease. Homocysteine is found either as free homocystine, cysteine-homocysteine mixed disulfide, or protein-bound homocyst(e)ine. In nonhomocystinuric subjects, most homocysteine molecules are detectable in the protein-bound form. Thus, protein-bound homocyst(e)ine in stored plasma which reflected total plasma homocyst(e)ine was determined in 241 patients with coronary artery disease (173 males and 68 females). The mean +/- SD total plasma homocyst(e)ine was 5.41 +/- 1.62 nmol/ml in male patients, 4.37 +/- 1.09 nmol/ml in male controls, 5.66 +/- 1.93 nmol/ml in female patients, and 4.16 +/- 1.62 nmol/ml in female controls. The differences between the patients with coronary artery disease and the controls were statistically significant (P less than 0.0005). PMID:3700650

  3. Homocyst(e)ine and risk of cardiovascular disease in the multiple risk factor intervention trial.

    Science.gov (United States)

    Evans, R W; Shaten, B J; Hempel, J D; Cutler, J A; Kuller, L H

    2000-01-01

    A nested case-control study was undertaken involving men participating in the Multiple Risk Factor Intervention Trial (MRFIT). Serum samples from 712 men, stored for upto 20 years, were analysed for homocyst(e)ine. Cases involved non-fatal myocardial infractions, identified through the active phase of the study, which ended on February 28, 1982, and deaths due to coronary heart disease, monitored through 1990. The non-fatal myocardial infarction occurred within 7 years of sample collection, whereas the majority of coronary heart disease deaths occurred more than 11 years after sample collection. Mean homocyst(e)ine concentrations were in the expected range and did not differ significantly between case patients and control subjects: myocardial infarction cases, 12.6 micromol/L; myocardial infarction controls, 13.1 micromol/L; coronary heart disease death cases, 12.8 micromol/L; and coronary heart disease controls, 12.7 micromol/L. Odds ratios versus quartile 1 for coronary heart disease deaths and myocardial infarctions combined were as follows: quartile 2, 1.03; quartile 3, 0.84; and quartile 4, 0.92. Thus, in this prospective study, no association of homocyst(e)ine concentration with heart disease was detected. Homocyst(e)ine levels were weakly associated with the acute-phase (C-reactive) protein. These results are discussed with respect to the suggestion that homocyst(e)ine is an independent risk factor for heart disease.

  4. Plasma folic acid cutoff value, derived from its relationship with homocyst(e)ine.

    Science.gov (United States)

    Brouwer, D A; Welten, H T; Reijngoud, D J; van Doormaal, J J; Muskiet, F A

    1998-07-01

    We established the cutoff value for plasma folic acid, using plasma homocyst(e)ine as the functional marker. To do this, we investigated the relationship of the plasma folic acid of 103 apparently healthy adults with their fasting plasma homocyst(e)ine and with their plasma homocyst(e)ine 6 h after oral methionine challenge (100 mg/kg). We also studied the relationship of their plasma folic acid with the decline of fasting plasma homocyst(e)ine after 7 days of folic acid supplementation (5 mg/day). The three approaches suggested a cutoff value of 10 nmol/L. The chances of individuals to significantly (P ine after folic acid supplementation proved significantly higher at plasma folic acid concentrations < or = 10 nmol/L, as compared with folic acid concentrations above this value (odds ratio, 5.02; 95% confidence interval, 1.87-13.73). We suggest adopting a 10 nmo/L plasma folic acid cutoff value on functional grounds.

  5. Repeated intermittent alcohol exposure during the third trimester-equivalent increases expression of the GABA(A) receptor δ subunit in cerebellar granule neurons and delays motor development in rats.

    Science.gov (United States)

    Diaz, Marvin R; Vollmer, Cyndel C; Zamudio-Bulcock, Paula A; Vollmer, William; Blomquist, Samantha L; Morton, Russell A; Everett, Julie C; Zurek, Agnieszka A; Yu, Jieying; Orser, Beverley A; Valenzuela, C Fernando

    2014-04-01

    Exposure to ethanol (EtOH) during fetal development can lead to long-lasting alterations, including deficits in fine motor skills and motor learning. Studies suggest that these are, in part, a consequence of cerebellar damage. Cerebellar granule neurons (CGNs) are the gateway of information into the cerebellar cortex. Functionally, CGNs are heavily regulated by phasic and tonic GABAergic inhibition from Golgi cell interneurons; however, the effect of EtOH exposure on the development of GABAergic transmission in immature CGNs has not been investigated. To model EtOH exposure during the 3rd trimester-equivalent of human pregnancy, neonatal pups were exposed intermittently to high levels of vaporized EtOH from postnatal day (P) 2 to P12. This exposure gradually increased pup serum EtOH concentrations (SECs) to ∼60 mM (∼0.28 g/dl) during the 4 h of exposure. EtOH levels gradually decreased to baseline 8 h after the end of exposure. Surprisingly, basal tonic and phasic GABAergic currents in CGNs were not significantly affected by postnatal alcohol exposure (PAE). However, PAE increased δ subunit expression at P28 as detected by immunohistochemical and western blot analyses. Also, electrophysiological studies with an agonist that is highly selective for δ-containing GABA(A) receptors, 4,5,6,7-tetrahydroisoxazolo[4,5-c]pyridine-3-ol (THIP), showed an increase in THIP-induced tonic current. Behavioral studies of PAE rats did not reveal any deficits in motor coordination, except for a delay in the acquisition of the mid-air righting reflex that was apparent at P15 to P18. These findings demonstrate that repeated intermittent exposure to high levels of EtOH during the equivalent of the last trimester of human pregnancy has significant but relatively subtle effects on motor coordination and GABAergic transmission in CGNs in rats. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Determination of free and total cyst(e)ine in plasma of dogs and cats.

    Science.gov (United States)

    Tôrres, Cristina L; Miller, Joshua W; Rogers, Quinton R

    2004-01-01

    In human blood, the amino acid cysteine forms disulfide bonds with itself and with other sulfhydryl compounds in their free form and with sulfhydryls in protein. Protein-bound cysteine is lost when plasma proteins are removed before amino acid analysis. The purpose of this study was to assess the time course and extent of cyst(e)ine (cysteine + half-cystine) loss in dog and cat plasma. An equal volume of 6% sulfosalicylic acid was added to plasma aliquots at 0, 2, 4, 10, 16, 24, 36, 48, 60, and 72 hours after separation of blood cells. Tris-2-carboxyethyl-phosphine hydrochloride (TCEP - HCl), a reducing agent, was used to regenerate total plasma cyst(e)ine after 3 months of sample storage (-20 degrees C). Initial free cyst(e)ine concentrations (mean +/- SEM) were higher in canine plasma (77 +/- 4 micromol/L) than in feline plasma (37 +/- 3 micromol/L). Free plasma cyst(e)ine concentrations in dogs and cats decreased after first-order kinetics, with a half-life of 23 and 69 hours, respectively. Total plasma cysteine after TCEP - HCl treatment was similar for dogs (290 micromol/L) and cats (296 micromol/L), but the percentage of free cysteine was higher (P = .02) in dogs (27%) than in cats (13%). Over half of the cyst(e)ine, homocysteine, cysteinylglycine, and glutathione were bound in vivo to plasma proteins. These results emphasize the importance of removing plasma proteins within 1 hour after blood collection for reliable assay of free plasma cyst(e)ine.

  7. Homocyst(e)ine and cardiovascular disease: a critical review of the epidemiologic evidence.

    Science.gov (United States)

    Eikelboom, J W; Lonn, E; Genest, J; Hankey, G; Yusuf, S

    1999-09-07

    To review epidemiologic studies on the association between homocyst(e)ine level and risk for cardiovascular disease and the potential benefits of homocysteine-decreasing therapies. Computerized and manual searches of the literature on total homocysteine levels and cardiovascular disease. Prospective studies and major retrospective epidemiologic studies evaluating the association between homocyst(e)ine levels and cardiovascular disease and the association between blood levels or dietary intake of folate, vitamin B6, and vitamin B12 and cardiovascular disease. Relevant data on patient population, plasma homocyst(e)ine levels, duration of follow-up, and main results were extracted from studies that met the inclusion criteria. The designs and results of studies included in this review are summarized. A formal meta-analysis was not performed because the studies were heterogeneous in method and design. Results of epidemiologic studies suggest that moderately elevated plasma or serum homocyst(e)ine levels are prevalent in the general population and are associated with an increased risk for cardiovascular disease, independent of classic cardiovascular risk factors. Simple, inexpensive, nontoxic therapy with folic acid, vitamin B6, and vitamin B12 reduces plasma homocyst(e)ine levels. Although the association between homocyst(e)ine levels and cardiovascular disease is generally strong and biologically plausible, the data from the prospective studies are less consistent. In addition, epidemiologic observations of an association between hyperhomocyst(e)inemia and cardiovascular risk do not prove the existence of a causal relation. Therefore, the effectiveness of folate, vitamin B6, and vitamin B12 in reducing cardiovascular morbidity and mortality requires rigorous testing in randomized clinical trials. Several such trials are under way; their results may greatly affect cardiovascular morbidity and mortality, given the simplicity and low cost of vitamin therapy.

  8. Systemic Manifestations in Pyridox(am)ine 5'-Phosphate Oxidase Deficiency.

    Science.gov (United States)

    Guerriero, Réjean M; Patel, Archana A; Walsh, Brian; Baumer, Fiona M; Shah, Ankoor S; Peters, Jurriaan M; Rodan, Lance H; Agrawal, Pankaj B; Pearl, Phillip L; Takeoka, Masanori

    2017-11-01

    Pyridoxine is converted to its biologically active form pyridoxal-5-phosphate (P5P) by the enzyme pyridox(am)ine 5'-phosphate oxidase and serves as a cofactor in nearly 200 reactions in the central nervous system. Pyridox(am)ine 5'-phosphate oxidase deficiency leads to P5P dependent epilepsy, typically a neonatal- or infantile-onset epileptic encephalopathy treatable with P5P or in some cases, pyridoxine. Following identification of retinopathy in a patient with pyridox(am)ine 5'-phosphate oxidase deficiency that was reversible with P5P therapy, we describe the systemic manifestations of pyridox(am)ine 5'-phosphate oxidase deficiency. A series of six patients with homozygous mutations of PNPO, the gene coding pyridox(am)ine 5'-phosphate oxidase, were evaluated in our center over the course of two years for phenotyping of neurological and systemic manifestations. Five of six were born prematurely, three had anemia and failure to thrive, and two had elevated alkaline phosphatase. A movement disorder was observed in two children, and a reversible retinopathy was observed in the most severely affected infant. All patients had neonatal-onset epilepsy and were on a continuum of developmental delay to profound encephalopathy. Electroencephalographic features included background slowing and disorganization, absent sleep features, and multifocal and generalized epileptiform discharges. All the affected probands carried a homozygous PNPO mutation (c.674 G>T, c.686 G>A and c.352G>A). In addition to the well-described epileptic encephalopathy, pyridox(am)ine 5'-phosphate oxidase deficiency causes a range of neurological and systemic manifestations. A movement disorder, developmental delay, and encephalopathy, as well as retinopathy, anemia, and failure to thrive add to the broadening clinical spectrum of P5P dependent epilepsy. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. The definition of the individual dose equivalent

    International Nuclear Information System (INIS)

    Ehrlich, Margarete

    1986-01-01

    A brief note examines the choice of the present definition of the individual dose equivalent, the new operational dosimetry quantity for external exposure. The consequences of the use of the individual dose equivalent and the danger facing the individual dose equivalent, as currently defined, are briefly discussed. (UK)

  10. Hydration and transparency of the rabbit cornea irradiated with UVB-doses of 0.25 J/cm(2) and 0.5 J/cm(2) compared with equivalent UVB radiation exposure reaching the human cornea from sunlight.

    Science.gov (United States)

    Cejka, Cestmír; Ardan, Taras; Sirc, Jakub; Michálek, Jiří; Beneš, Jiří; Brůnová, Blanka; Rosina, Jozef

    2011-07-01

    Exposure of the cornea to UV radiation from sunlight evokes intraocular inflammation, photokeratitis. Photokeratitis is caused by UVB radiation. It is accompanied by changes of corneal hydration and light absorption. The aim of this study was to examine the effect of two UVB doses on corneal optics in rabbits and to compare these UVB doses with the equivalent exposure of UVB radiation reaching the human cornea from sunlight. Rabbit corneas were irradiated with a daily UVB dose of 0.25 J/cm(2) or 0.5 J/cm(2) for 4 days. One day after finishing the irradiations the rabbits were sacrificed and corneal light absorption measured using our spectrophotometrical method. Corneal hydration was examined using an ultrasonic Pachymeter every experimental day before the irradiation procedure and the last day before sacrificing the animals. Changes in corneal optics appeared after the repeated exposure of the cornea to a UVB dose of 0.25 J/ cm(2) and massively increased after the repeated exposure of the cornea to a UVB dose of 0.5 J/cm(2). The first significant changes in corneal hydration appeared after a single exposure of the cornea to a UVB dose of 0.25 J/cm(2). Changes in corneal hydration appeared after the exposure of the rabbit cornea to a single UVB dose equivalent to 2.6 hours of solar UVB radiation reaching the human cornea, as measured by UVB sensors embedded in the eyes of mannequin heads facing the sun on a beach at noon in July. Repeated exposure of the rabbit cornea to the same UVB dose evoked profound changes in corneal optics. Although comparison of experimental and outdoor conditions are only approximate, the results in rabbits point to the danger for the human eye from UVB radiation when short stays in sunlight are repeated for several consecutive days without UV protection.

  11. Editorial: New operational dose equivalent quantities

    International Nuclear Information System (INIS)

    Harvey, J.R.

    1985-01-01

    The ICRU Report 39 entitled ''Determination of Dose Equivalents Resulting from External Radiation Sources'' is briefly discussed. Four new operational dose equivalent quantities have been recommended in ICRU 39. The 'ambient dose equivalent' and the 'directional dose equivalent' are applicable to environmental monitoring and the 'individual dose equivalent, penetrating' and the 'individual dose equivalent, superficial' are applicable to individual monitoring. The quantities should meet the needs of day-to-day operational practice, while being acceptable to those concerned with metrological precision, and at the same time be used to give effective control consistent with current perceptions of the risks associated with exposure to ionizing radiations. (U.K.)

  12. Acute Mountain Sickness at 4500 m is not Altered by Repeated Eight-Hour Exposures to 3200-3550 m Normobaric Hypoxic Equivalent,

    Science.gov (United States)

    1987-09-10

    subject had his own numbered device, which was disassembled, washed and disinfected ( benzalkonium chloride , 1:1000 v/v) each evening. 4 Subjects...fluctuations throughout the 10-day period after the reduction in altitude equivalent which occurred during day I, either in the group mean values (shown) or...significant reduction in hemoglobin concentration in the control group over the sea level treatment period, with a concomitant, but non-significant

  13. Utilisation de la Technique D\\'électrophorèse des Protéines Totales ...

    African Journals Online (AJOL)

    Utilisation de la Technique D\\'électrophorèse des Protéines Totales sur Gel de Polyacrylamide-SDS (SDS-PAGE) pour L\\'étude de la Diversité des Rhizobiums D\\'Acacia tortilis (Forsk.) Hayne Subsp. Raddiana (Savi) Brenan.

  14. Report of the meeting of the INES advisory committee, 16-17 October 1995

    International Nuclear Information System (INIS)

    1995-01-01

    The INES advisory committee discussed at its meeting the following issues: report on results from questionnaires, review of events, proposed simplification of the user's manual, guidance on relationship between initiators and safety functions, computerized rating procedure, future work of the advisory committee

  15. INES 2000 ja Läänemere ülikool / Annika Tenno

    Index Scriptorium Estoniae

    Tenno, Annika

    2000-01-01

    Läänemere Ülikooli programmiga (The Baltic University Programme) seotud õppejõududel oli võimalus osaleda INES 2000 konverentsil Stockholmis 14.-18. juunil̀2000, peateemaks "Challenges for Science and Engineering in the 21st Century". Tallinna Pedagoogikaülikooli esindajaks oli Tiina Elvisto

  16. The De-Genderization of Knowledge Production: The Case of Sor Juana Ines de la Cruz.

    Science.gov (United States)

    Salazar, Norma

    1994-01-01

    All societies have official knowledge. Life of Sor Juana Ines de la Cruz, 17th-century nun and literary genius, illustrates who discovers knowledge is more important than what knowledge is promulgated. Real issue was not what Sor Juana wrote but whether nun or woman should engage in producing and publishing knowledge. Her efforts have inspired…

  17. The W(h)ine Club: Women Finding Joy in Academic Work

    Science.gov (United States)

    Selepe, Mosa; Grobler, Christa; Dicks, Emsie; Oldewage-Theron, Wilna

    2012-01-01

    The W(h)ine Club is a multidisciplinary women's research team which has been working together for the past 10 years. The idea for this Viewpoint piece grew as we participated in a Women in Research programme. The aim of the programme was to improve academic publications among women. A group of us in the programme found ourselves repeatedly…

  18. Elevated circulating homocyst(e)ine levels in placental vascular disease and associated pre-eclampsia.

    Science.gov (United States)

    Wang, J; Trudinger, B J; Duarte, N; Wilcken, D E; Wang, X L

    2000-07-01

    We examined the hypothesis that hyperhomocyst(e)inaemia in the maternal or fetal circulation is associated with placental vascular disease with either the maternal syndrome of pre-eclampsia and/or fetal syndrome of growth restriction. Maternal plasma homocyst(e)ine levels were significantly higher in pregnancies complicated by pre-eclampsia, pregnancies with evidence of umbilical placental vascular disease, and pregnancies with both complications compared with the normal pregnancy group. In the fetal circulation mean plasma homocyst(e)ine concentration was significantly higher in the pre-eclampsia group compared with the normal group. The results suggest that hyperhomocyst(e)inaemia may be a risk marker for placental vascular disease and maternal pre-eclampsia. The elevated fetal plasma homocyst(e)ine concentrations, found only in the group of pregnancies with pre-eclampsia in the absence of umbilical placental vascular disease, may be due to an effect of placental vascular disease on homocyst(e)ine transfer from the maternal to fetal circulation.

  19. Determinants of plasma homocyst(e)ine in patients with nephrotic syndrome.

    Science.gov (United States)

    Joven, J; Arcelús, R; Camps, J; Ordóñez-Llanos, J; Vilella, E; González-Sastre, F; Blanco-Vaca, F

    2000-01-01

    Hyperhomocyst(e)inemia is an independent risk factor for atherothrombosis in several clinical settings in which renal function is impaired, but its prevalence in the nephrotic syndrome has not been investigated in detail, even though this syndrome provides an excellent model in which to study a possible link between albuminuria, proteinuria, and hyperhomocyst(e)inemia. We obtained plasma and urine from 27 patients with biopsy-confirmed membranous glomerulonephritis presenting nephrotic syndrome and 27 matched controls and determined the concentrations of homocyst(e)ine and proteins considered putative markers of glomerular and tubular function. Hyperhomocyst(e)inemia, defined as the mean +SD of the plasma homocyst(e)ine concentration of the controls [plasma homocyst(e)ine concentration >10.8 micromol/l] was present in 26% of the patients with nephrotic syndrome but in only 7.4% of the controls. Furthermore, the degree of hyperhomocyst(e)inemia was more severe in the nephrotic patients than in the controls. The existence of renal failure, tubular damage, and, interestingly, relatively well conserved glomerular function barrier were the main predictors of increased levels of plasma homocyst(e)ine. In conclusion, hyperhomocyst(e)inemia is a frequent cardiovascular risk factor present in patients with nephrotic syndrome and renal failure, but it is not directly associated with proteinuria.

  20. Report of the meeting of the INES advisory committee, 16-17 October 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    The INES advisory committee discussed at its meeting the following issues: report on results from questionnaires, review of events, proposed simplification of the user`s manual, guidance on relationship between initiators and safety functions, computerized rating procedure, future work of the advisory committee.

  1. Potential clinical and economic effects of homocyst(e)ine lowering.

    Science.gov (United States)

    Nallamothu, B K; Fendrick, A M; Rubenfire, M; Saint, S; Bandekar, R R; Omenn, G S

    Elevated total homocyst(e)ine levels (>/=11 micromol/L) have been identified as a potential risk factor for coronary heart disease. However, the benefits expected from lowering homocyst(e)ine levels with folic acid and vitamin B(12) supplementation have yet to be demonstrated in clinical trials. We constructed a decision analytic model to estimate the clinical benefits and economic costs of 2 homocyst(e)ine-lowering strategies: (1) "treat all"-no screening, daily supplementation with folic acid (400 microg) and vitamin B(12) (cyanocobalamin; 500 microg) for all; (2) "screen and treat"-screening, followed by daily supplementation with folic acid and vitamin B(12) for individuals with elevated homocyst(e)ine levels. Simulated cohorts of 40-year-old men and 50-year-old women in the general population were evaluated. In the base-case analysis, we assumed that lowering elevated levels would reduce excess coronary heart disease risk by 40%; however, this assumption and others were evaluated across a broad range of potential values using sensitivity analysis. Primary outcomes were discounted costs per life-year saved. Although the treat-all strategy was slightly more effective overall, the screen and treat strategy resulted in a much lower cost per life-year saved ($13,600 in men and $27,500 in women) when compared with no intervention. Incremental cost-effectiveness ratios for the treat-all strategy compared with the screen and treat strategy were more than $500,000 per life-year saved in both cohorts. Sensitivity analysis showed that cost-effectiveness ratios for the screen and treat strategy remained less than $50,000 per life-year saved under several unfavorable scenarios, such as when effective homocyst(e)ine lowering was assumed to reduce the relative risk of coronary heart disease-related death by only 11% in men or 23% in women. Homocyst(e)ine lowering with folic acid and vitamin B(12) supplementation could result in substantial clinical benefits at reasonable

  2. Eye lens dose correlations with personal dose equivalent and patient exposure in paediatric interventional cardiology performed with a fluoroscopic biplane system.

    Science.gov (United States)

    Alejo, L; Koren, C; Corredoira, E; Sánchez, F; Bayón, J; Serrada, A; Guibelalde, E

    2017-04-01

    To analyse the correlations between the eye lens dose estimates performed with dosimeters placed next to the eyes of paediatric interventional cardiologists working with a biplane system, the personal dose equivalent measured on the thorax and the patient dose. The eye lens dose was estimated in terms of H p (0.07) on a monthly basis, placing optically stimulated luminescence dosimeters (OSLDs) on goggles. The H p (0.07) personal dose equivalent was measured over aprons with whole-body OSLDs. Data on patient dose as recorded by the kerma-area product (P KA ) were collected using an automatic dose management system. The 2 paediatric cardiologists working in the facility were involved in the study, and 222 interventions in a 1-year period were evaluated. The ceiling-suspended screen was often disregarded during interventions. The annual eye lens doses estimated on goggles were 4.13±0.93 and 4.98±1.28mSv. Over the aprons, the doses obtained were 10.83±0.99 and 11.97±1.44mSv. The correlation between the goggles and the apron dose was R 2 =0.89, with a ratio of 0.38. The correlation with the patient dose was R 2 =0.40, with a ratio of 1.79μSvGy -1 cm -2 . The dose per procedure obtained over the aprons was 102±16μSv, and on goggles 40±9μSv. The eye lens dose normalized to P KA was 2.21±0.58μSvGy -1 cm -2 . Measurements of personal dose equivalent over the paediatric cardiologist's apron are useful to estimate eye lens dose levels if no radiation protection devices are typically used. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. Monte-Carlo and multi-exposure assessment for the derivation of criteria for disinfection byproducts and volatile organic compounds in drinking water: Allocation factors and liter-equivalents per day.

    Science.gov (United States)

    Akiyama, Megumi; Matsui, Yoshihiko; Kido, Junki; Matsushita, Taku; Shirasaki, Nobutaka

    2018-06-01

    The probability distributions of total potential doses of disinfection byproducts and volatile organic compounds via ingestion, inhalation, and dermal exposure were estimated with Monte Carlo simulations, after conducting physiologically based pharmacokinetic model simulations to takes into account the differences in availability between the three exposures. If the criterion that the 95th percentile estimate equals the TDI (tolerable daily intake) is regarded as protecting the majority of a population, the drinking water criteria would be 140 (trichloromethane), 66 (bromodichloromethane), 157 (dibromochloromethane), 203 (tribromomethane), 140 (dichloroacetic acid), 78 (trichloroacetic acid), 6.55 (trichloroethylene, TCE), and 22 μg/L (perchloroethylene). The TCE criterion was lower than the Japanese Drinking Water Quality Standard (10 μg/L). The latter would allow the intake of 20% of the population to exceed the TDI. Indirect inhalation via evaporation from water, especially in bathrooms, was the major route of exposure to compounds other than haloacetic acids (HAAs) and accounted for 1.2-9 liter-equivalents/day for the median-exposure subpopulation. The ingestion of food was a major indirect route of exposure to HAAs. Contributions of direct water intake were not very different for trihalomethanes (30-45% of TDIs) and HAAs (45-52% of TDIs). Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Protection by imidazol(ine) drugs and agmatine of glutamate-induced neurotoxicity in cultured cerebellar granule cells through blockade of NMDA receptor.

    Science.gov (United States)

    Olmos, G; DeGregorio-Rocasolano, N; Paz Regalado, M; Gasull, T; Assumpció Boronat, M; Trullas, R; Villarroel, A; Lerma, J; García-Sevilla, J A

    1999-07-01

    This study was designed to assess the potential neuroprotective effect of several imidazol(ine) drugs and agmatine on glutamate-induced necrosis and on apoptosis induced by low extracellular K+ in cultured cerebellar granule cells. Exposure (30 min) of energy deprived cells to L-glutamate (1-100 microM) caused a concentration-dependent neurotoxicity, as determined 24 h later by a decrease in the ability of the cells to metabolize 3-(4,5-dimethythiazol-2-yl)-2,5-diphenyltetrazoliumbromide (MTT) into a reduced formazan product. L-glutamate-induced neurotoxicity (EC50=5 microM) was blocked by the specific NMDA receptor antagonist MK-801 (dizocilpine). Imidazol(ine) drugs and agmatine fully prevented neurotoxicity induced by 20 microM (EC100) L-glutamate with the rank order (EC50 in microM): antazoline (13)>cirazoline (44)>LSL 61122 [2-styryl-2-imidazoline] (54)>LSL 60101 [2-(2-benzofuranyl) imidazole] (75)>idazoxan (90)>LSL 60129 [2-(1,4-benzodioxan-6-yl)-4,5-dihydroimidazole](101)>RX82 1002 (2-methoxy idazoxan) (106)>agmatine (196). No neuroprotective effect of these drugs was observed in a model of apoptotic neuronal cell death (reduction of extracellular K+) which does not involve stimulation of NMDA receptors. Imidazol(ine) drugs and agmatine fully inhibited [3H]-(+)-MK-801 binding to the phencyclidine site of NMDA receptors in rat brain. The profile of drug potency protecting against L-glutamate neurotoxicity correlated well (r=0.90) with the potency of the same compounds competing against [3H]-(+)-MK-801 binding. In HEK-293 cells transfected to express the NR1-1a and NR2C subunits of the NMDA receptor, antazoline and agmatine produced a voltage- and concentration-dependent block of glutamate-induced currents. Analysis of the voltage dependence of the block was consistent with the presence of a binding site for antazoline located within the NMDA channel pore with an IC50 of 10-12 microM at 0 mV. It is concluded that imidazol(ine) drugs and agmatine are

  5. Short-term folic acid supplementation induces variable and paradoxical changes in plasma homocyst(e)ine concentrations.

    Science.gov (United States)

    Malinow, M R; Duell, P B; Williams, M A; Kruger, W D; Evans, A A; Anderson, P H; Block, P C; Hess, D L; Upson, B M; Graf, E E; Irvin-Jones, A; Wang, L

    2001-01-01

    Folic acid is presently the mainstay of treatment for most subjects with elevated plasma homocyst(e)ine concentrations [Plasma or serum homocyst(e)ine, or total homocysteine, refers to the sum of the sulfhydryl amino acid homocysteine and the homocysteinyl moieties of the disulfides homocystine and homocystein-cysteine, whether free or bound to plasma proteins.] Changes in homocyst(e)ine in response to folic acid supplementation are characterized by considerable interindividual variation. The purpose of this study was to identify factors that contribute to heterogeneity in short-term responses to folic acid supplementation. The effects of folic acid supplementation (1 or 2 mg per day) for 3 wk on plasma homocyst(e)ine concentrations were assessed in 304 men and women. Overall, folic acid supplementation increased mean plasma folate 31.5 +/- 98.0 nmol/L and decreased mean plasma homocyst(e)ine concentrations 1.2 +/- 2.4 micromol/L. There was evidence of substantial interindividual variation in the homocyst(e)ine response from -18.5 to +7.1 micromol/L, including an increase in homocyst(e)ine in 20% of subjects (mean increase 1.5 +/- 1.4 micromol/L). Basal homocyst(e)ine, age, male gender, cigarette smoking, use of multivitamins, methylene tetrahydrofolate reductase, and cystathionine beta-synthase polymorphisms accounted for 47.6% of the interindividual variability in the change in homocyst(e)ine after folic acid supplementation, but about 50% of variability in response to folic acid was not explained by the variables we studied.

  6. Homocyst(e)ine and risk of cerebral infarction in a biracial population : the stroke prevention in young women study.

    Science.gov (United States)

    Kittner, S J; Giles, W H; Macko, R F; Hebel, J R; Wozniak, M A; Wityk, R J; Stolley, P D; Stern, B J; Sloan, M A; Sherwin, R; Price, T R; McCarter, R J; Johnson, C J; Earley, C J; Buchholz, D W; Malinow, M R

    1999-08-01

    Genetic enzyme variation and vitamin intake are important determinants of blood homocyst(e)ine levels. The prevalence of common genetic polymorphisms influencing homocyst(e)ine levels varies by race, and vitamin intake varies by socioeconomic status. Therefore, we examined the effect of vitamin intake, race, and socioeconomic status on the association of homocyst(e)ine with stroke risk. All 59 hospitals in the greater Baltimore-Washington area participated in a population-based case-control study of stroke in young women. One hundred sixty-seven cases of first ischemic stroke among women aged 15 to 44 years were compared with 328 controls identified by random-digit dialing from the same region. Risk factor data were collected by standardized interview and nonfasting phlebotomy. Plasma homocyst(e)ine was measured by high-performance liquid chromatography and electrochemical detection. Blacks and whites did not differ in median homocyst(e)ine levels, nor did race modify the association between homocyst(e)ine and stroke. After adjustment for cigarettes per day, poverty status, and regular vitamin use, a plasma homocyst(e)ine level of >/=7.3 micromol/L was associated with an odds ratio for stroke of 1.6 (95% CI, 1.1 to 2.5). The association between elevated homocyst(e)ine and stroke was independent not only of traditional vascular risk factors but also of vitamin use and poverty status. The degree of homocyst(e)ine elevation associated with an increased stroke risk in young women is lower than that previously reported for middle-aged men and the elderly and was highly prevalent, being present in one third of the control group.

  7. Politico-economic equivalence

    DEFF Research Database (Denmark)

    Gonzalez Eiras, Martin; Niepelt, Dirk

    2015-01-01

    Traditional "economic equivalence'' results, like the Ricardian equivalence proposition, define equivalence classes over exogenous policies. We derive "politico-economic equivalence" conditions that apply in environments where policy is endogenous and chosen sequentially. A policy regime and a st......Traditional "economic equivalence'' results, like the Ricardian equivalence proposition, define equivalence classes over exogenous policies. We derive "politico-economic equivalence" conditions that apply in environments where policy is endogenous and chosen sequentially. A policy regime...... their use in the context of several applications, relating to social security reform, tax-smoothing policies and measures to correct externalities....

  8. Evaluation of operational incidents in the research reactor RP-10 according to scale INES; Evaluacion de incidentes operacionales en el reactor de investigacion RP-10 segun escala INES

    Energy Technology Data Exchange (ETDEWEB)

    Arrieta, Rolando W.B.; Vela Mora, Mariano, E-mail: rarrieta@ipen.gob.pe, E-mail: mvela@ipen.gob.pe [Instituto Peruano de energia Nuclear, Lima (Peru). Dept. de Operacion de Reactores

    2013-07-01

    This report presents the evaluation of the events in 2011 in the RP-10 Nuclear Reactor Nuclear Center Huarangal from the point of view of safety. To classify these events produced is used Scale International Nuclear and Radiological Event Scale (INES) to facilitate a common understanding between the technical community, the media and the general public. From the results we can say that in 2011 all related to security events that occurred in the RP -10 are classified as 'below scale' or no safety significance. (author)

  9. Relation of plasma homocyst(e)ine to cerebral infarction and cerebral atherosclerosis.

    Science.gov (United States)

    Yoo, J H; Chung, C S; Kang, S S

    1998-12-01

    A number of investigations support the theory that the elevated plasma homocyst(e)ine is associated with occlusive vascular disease. The aim of this study is to examine whether moderate hyperhomocyst(e)inemia is an independent risk factor for cerebral infarction. In addition, we examined the association between plasma homocyst(e)ine and the severity of cerebral atherosclerosis. We conducted a hospital-based case-control study with 140 male controls and 78 male patients with nonfatal cerebral infarction, aged between 39 and 82 years. Plasma homocyst(e)ine levels were analyzed in 218 subjects. Fifty-five patients were evaluated for cerebral vascular stenosis by MR angiography. The mean plasma level of homocyst(e)ine was higher in cases than in controls (11.8+/-5.6 versus 9.6+/-4.1 micromol/L; P=0.002). The proportion of subjects with moderate hyperhomocyst(e)inemia was significantly higher in cases than in controls (16.7% versus 5.0%; P=0.004). Based on the logistic regression model, the odds ratio of the highest 5% of homocyst(e)ine levels in control group was 4.17 (95% confidence interval, 3.71 to 4. 71)(P=0.0001). After additional adjustment for total cholesterol, hypertension, smoking, diabetes, and age, the odds ratio was 1.70 (95% confidence interval, 1.48 to 1.95) (P=0.0001). The plasma homocyst(e)ine levels of patients having vessels with 3 or 2 stenosed sites were significantly higher than those of patients having vessels with 1 stenosed site or normal vessels (14.6+/-1.4, 11.0+/-1.4 versus 7.8+/-1.5, 8.9+/-1.4 micromol/L respectively; P<0. 02). Multiple logistic regression analysis revealed that moderate hyperhomocyst(e)ienemia was significantly associated with the number of stenosed vessels (P=0.001). These findings suggest that moderate hyperhomocyst(e)inemia is an independent risk factor for cerebral infarction and may predict the severity of cerebral atherosclerosis in patients with cerebral infarction.

  10. Mutations du gène d'apoprotéine B100 au cours des dyslipidémies ...

    African Journals Online (AJOL)

    Les apolipoprotéines constituent la partie du complexe lipoprotéique responsable de son métabolisme et son transport. L'objectif de cette étude a été de rechercher les mutations des exons 26 et 29 du gène d'Apolipoprotéine B100 chez les personnes vivant avec le VIH (PV-VIH) présentant une dyslipidémie. Cette étude ...

  11. Kulinaarne palverännak piki Telliskivi tänavat / Martin Hanson, Ines Haak

    Index Scriptorium Estoniae

    Hanson, Martin, 1984-

    2013-01-01

    Toidukriitik Martin Hanson ja sisearhitekt Ines Haak Tallinna Telliskivi tänavat palistavatest söögipaikadest: restoran Kolm Sibulat (sisearhitektuur: Aivar Mühlbach, omanikud, 2012-2013), bistroo Kukeke (Anni Arro, Riina Eerik, 2011-2012), kohvik Reval (Ville Lausmäe, Kadi Karmann, Peeter Klaas, 2013), restoran F-Hoone (Ville Jehe, Steve Heinlo, 2010), baar Pudel (Raul Tiitus, Tarmo Piirmets, 2012-2013)

  12. Crise convulsive chez les abuseurs de Tramadol et caféine: à ...

    African Journals Online (AJOL)

    Nous rapportons Huit cas de crises convulsives diagnostiquées comme maladie épileptique après ingestion de Tramadol et d'autres substances psychotropes dont la Caféine dans une région ou maladie épileptique et addiction au café sont fréquentes. L'objectif de ce travail était d'informer les praticiens sur le risque de ...

  13. Research on classification of nuclear and radiological accident from IAEA threat category with estimation of INES scale

    International Nuclear Information System (INIS)

    Cha, Seok Ki; Kim, Siu

    2017-01-01

    As there is increasing use of nuclear energy and radiation while information on nuclear related accidents are accumulated, international interest in nuclear and radiation incidents is increasing rapidly. Because of the specificity of nuclear energy and radiation, the damage caused by such accidents will be spread to the larger area around the accident point due to the radiation and cause biological damage and mental-psychological damage. The purpose of this study is to categorize historical incidents using the Threat Category concept described in the publication of IAEA Safety Guide GS-G-2.1. In addition to categorizing actual events and accidents into Threat Categories, causes of occurrences, the type of radioactive source which leads to the main threats, the type of radiation exposure, and the type of patient are organized in detail. As a result of the analysis of representative historical cases, most accident cases caused by 'Nuclear Energy-Related Business Operator' correspond to 1 (Anomaly) ~ 4 (Accident with Local Consequences) in the INES Scale by IAEA. From the some accident cases, while the radiological damage can be seen to be local, but it can be seen that the possibility of 6 (Serious Accident) can not be absolutely excluded.

  14. Research on classification of nuclear and radiological accident from IAEA threat category with estimation of INES scale

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Seok Ki [Dept. of Nuclear engineering, Univ of SeJong, Seoul (Korea, Republic of); Kim, Siu [Korea Nuclear International Cooperation Foundation, Daejeon (Korea, Republic of)

    2017-04-15

    As there is increasing use of nuclear energy and radiation while information on nuclear related accidents are accumulated, international interest in nuclear and radiation incidents is increasing rapidly. Because of the specificity of nuclear energy and radiation, the damage caused by such accidents will be spread to the larger area around the accident point due to the radiation and cause biological damage and mental-psychological damage. The purpose of this study is to categorize historical incidents using the Threat Category concept described in the publication of IAEA Safety Guide GS-G-2.1. In addition to categorizing actual events and accidents into Threat Categories, causes of occurrences, the type of radioactive source which leads to the main threats, the type of radiation exposure, and the type of patient are organized in detail. As a result of the analysis of representative historical cases, most accident cases caused by 'Nuclear Energy-Related Business Operator' correspond to 1 (Anomaly) ~ 4 (Accident with Local Consequences) in the INES Scale by IAEA. From the some accident cases, while the radiological damage can be seen to be local, but it can be seen that the possibility of 6 (Serious Accident) can not be absolutely excluded.

  15. I awake, she slept. Sor Juana Ines and Juan Rulfo or the new Latin American poetic condition

    Directory of Open Access Journals (Sweden)

    Hoover Delgado

    2015-12-01

    Full Text Available The article examines how Sor Juana Ines de la Cruz and Juan Rulfo, in dialogue with the literary tradition –especially with the work of Dante, Gongorism and the modern tradition– build a Latin American poetic condition. To that end, it studies the long oneiric ascent of Sor Juana, in First Dream; and Susana San Juan’s story, in Pedro Paramo. For the analysis, it goes to the concepts of resistance when suffering and the signals to transcendence provided by Maria Zambrano in her reflections on the essential condition of the human. It explains how Sor Juana and Susana San Juan offer such resistance: Sor Juana through the journey of knowledge, the sovereignty of the body, the exposure of the precariousness of life and the metaphor of the ascent; Susana, through the fall, madness and eroticism. Finally, it interprets in both characters, the appropriation of the signs of transcendence: the revaluation of the moment, of dreams and the creation-destruction of the divine. It concludes by showing how Sor Juana takes the momentum that starts in Europe with Montaigne, Bacon, the Renaissance and the Golden Age and proposes significant transformations that allow speaking of a different poetic condition. And how Rulfo, starting from the American mythic-religious condition, the non-place, the ontological indefiniteness, stops at the image of Purgatory: showing there the luminous consciousness, the unleashed eroticism and the sacralized madness of Susana as a relief, a possibility of leakage and human of redemption of the sentence.

  16. Depletion of circulating cyst(e)ine by oral and intravenous mesna.

    Science.gov (United States)

    Stofer-Vogel, B.; Cerny, T.; Küpfer, A.; Junker, E.; Lauterburg, B. H.

    1993-01-01

    The sulfhydryl status of normal and tumour cells is critically important in determining their susceptibility to various cytostatic agents. As a sulfhydryl compound, mesna (sodium 2-mercaptoethane-sulfonate) which is used in large doses to prevent haemorrhagic cystitis associated with certain chemotherapeutic regimens might derange cellular thiol homeostasis. In order to investigate the effects of mesna on the concentrations of thiols in plasma, cysteine, glutathione and their disulfides were measured by HPLC following the oral and intravenous administration of mesna to healthy volunteers. After 7.3 mmol mesna i.v. free cysteine rose from 8.2 (95% CI 7.0-9.4) nmol ml-1 to 53.6 (47.4-59.8) nmol ml-1 at 5 min, most likely due to reduction of circulating cystine by the sulfhydryl drug. This initial rise was followed by a marked decrease of total cyst(e)ine in plasma from 276 (215-337) nmol ml-1 to a nadir of 102 (89-115) nmol ml-1 between 30-120 min after infusion, most likely due to an increased uptake of cysteine into cells and an increased urinary excretion of cyst(e)ine. Qualitatively similar changes were seen after oral mesna. The present data indicate that mesna depletes circulating cyst(e)ine and may thereby markedly alter the sulfhydryl status of cells in vivo although the drug itself is not taken up by most cells. PMID:8353049

  17. Elevated levels of plasma homocyst(e)ine and asymmetric dimethylarginine in elderly patients with stroke.

    Science.gov (United States)

    Yoo, J H; Lee, S C

    2001-10-01

    Cerebrovascular risk factors, including hypertension, smoking, diabetes mellitus, aging, dyslipidemia, and hyperhomocyst(e)inemia are linked to endothelial dysfunction. Endothelial-derived nitric oxide (NO) has inhibitory effects on key processes in atherothrombosis. Although asymmetric dimethylarginine (ADMA), an endogenous inhibitor of NO synthase, is associated with atherosclerotic disease, there has been no report on association of ADMA with ischemic stroke. Here we investigated the relation of plasma ADMA, stroke, and homocyst(e)inemia in the elderly. Plasma ADMA and homocyst(e)ine concentration was determined using high-performance liquid chromatography and fluorescence detection. Patients with ischemic stroke had significantly higher concentrations of plasma ADMA than controls (1.85+/-1.32 vs. 0.93+/-0.32 micromol/l, P=0.0001). After adjustment for risk factors, elevated ADMA levels, above 90th percentile of normal controls (> or =1.43 micromol/l) was associated with stroke (OR=6.05, 95% CI; 2.77-13.3, P=0.02). ADMA plasma levels were positively correlated to homocyst(e)ine levels (r=0.43, P=0.01). Multiple logistic regression analysis revealed that hyperhomocyst(e)inemia (plasma homocyst(e)ine concentration > or =15.0 micromol/l) was a significant predictor of elevated ADMA level. Altogether, findings indicate that elevated ADMA concentrations are at increased risk for ischemic stroke in the elderly, and may account for increased risk of stroke in patients with hyperhomocyst(e)inemia.

  18. Dioxin-related compounds in breast milk of women from Vietnamese e-waste recycling sites: levels, toxic equivalents and relevance of non-dietary exposure.

    Science.gov (United States)

    Tue, Nguyen Minh; Katsura, Kana; Suzuki, Go; Tuyen, Le Huu; Takasuga, Takumi; Takahashi, Shin; Viet, Pham Hung; Tanabe, Shinsuke

    2014-08-01

    Although informal e-waste recycling sites (EWRSs) are hotspots of both polychlorinated and polybrominated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs and PBDD/Fs), human exposure to the latter has not been studied in details. This study investigated the accumulation levels and profiles of dioxin-related compounds (DRCs) in breast milk samples from women living in two Vietnamese EWRSs and estimated the intake contribution from e-waste-related exposure. Screening results using Dioxin-Responsive Chemically Activated LUciferase gene eXpression assay (DR-CALUX) showed higher dioxin-like (DL) activities in samples from the EWRS Bui Dau than in those from the EWRS Trang Minh and a reference site (2.3-10 vs 1.7-4.8 and 0.60-5.7 pg CALUX-TEQ/g lipid, n=10, 6 and 9, respectively). Chemical analysis results of selected samples show that the WHO-TEQ levels of PCDD/Fs, DL-PCBs and PBDD/Fs in EWRS samples were not significantly higher than in those from the reference site (0.22-7.4 vs 1.1-3.0 pg/g lipid) and within the Vietnamese background range, but women involved in recycling accumulated higher concentrations of PCDFs (13-15 vs 2.3-8.8 pg/g lipid) and PBDFs (1.1-1.5 vs <1.1 pg/g lipid). By comparing the DRC profile in milk of these women with the reported profile in house dust from the same site, dust ingestion was estimated to contribute most of the intake for tetraBDF, 37 per cent to 55 per cent for penta-octaCDFs, but less than twenty per cent for PCDDs and DL-PCBs, and 26 per cent for total WHO-TEQs. The DL activities in some EWRS milk samples were not fully explained by chemical data, suggesting contribution from unidentified compounds. The estimated WHO-TEQ intake doses for breastfed infants (1.3-33 pg/kg/d) mostly exceeded the tolerable value, especially for those living in the EWRSs; and unidentified DRCs might increase further the dioxin-related health risk. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. INES: The International Nuclear and Radiological Event Scale User's Manual. 2008 Edition

    International Nuclear Information System (INIS)

    2009-05-01

    The International Nuclear and Radiological Event Scale is used for promptly and consistently communicating to the public the safety significance of events associated with sources of radiation. It covers a wide spectrum of practices, including industrial use such as radiography, use of radiation sources in hospitals, activities at nuclear facilities, and the transport of radioactive material. By putting events from all these practices into a proper perspective, use of INES can facilitate a common understanding between the technical community, the media and the public. The scale was developed in 1990 by international experts convened by the IAEA and the OECD Nuclear Energy Agency (OECD/NEA). It originally reflected the experience gained from the use of similar scales in France and Japan as well as consideration of possible scales in several countries. Since then, the IAEA has managed its development in cooperation with the OECD/NEA and with the support of more than 60 designated National Officers who officially represent the INES member States in the biennial technical meeting of INES. Initially the scale was applied to classify events at nuclear power plants, and then was extended and adapted to enable it to be applied to all installations associated with the civil nuclear industry. More recently, it has been extended and adapted further to meet the growing need for communication of the significance of all events associated with the transport, storage and use of radioactive material and radiation sources. This revised manual brings together the guidance for all uses into a single document. Events are classified on the scale at seven levels: Levels 4-7 are termed 'accidents' and Levels 1-3 'incidents'. Events without safety significance are classified as 'Below Scale/Level 0'. Events that have no safety relevance with respect to radiation or nuclear safety are not classified on the scale. For communication of events to the public, a distinct phrase has been

  20. Equivalence principles and electromagnetism

    Science.gov (United States)

    Ni, W.-T.

    1977-01-01

    The implications of the weak equivalence principles are investigated in detail for electromagnetic systems in a general framework. In particular, it is shown that the universality of free-fall trajectories (Galileo weak equivalence principle) does not imply the validity of the Einstein equivalence principle. However, the Galileo principle plus the universality of free-fall rotation states does imply the Einstein principle.

  1. The bystander effect model of Brenner and Sachs fitted to lung cancer data in 11 cohorts of underground miners, and equivalence of fit of a linear relative risk model with adjustment for attained age and age at exposure

    International Nuclear Information System (INIS)

    Little, M P

    2004-01-01

    Bystander effects following exposure to α-particles have been observed in many experimental systems, and imply that linearly extrapolating low dose risks from high dose data might materially underestimate risk. Brenner and Sachs (2002 Int. J. Radiat. Biol. 78 593-604; 2003 Health Phys. 85 103-8) have recently proposed a model of the bystander effect which they use to explain the inverse dose rate effect observed for lung cancer in underground miners exposed to radon daughters. In this paper we fit the model of the bystander effect proposed by Brenner and Sachs to 11 cohorts of underground miners, taking account of the covariance structure of the data and the period of latency between the development of the first pre-malignant cell and clinically overt cancer. We also fitted a simple linear relative risk model, with adjustment for age at exposure and attained age. The methods that we use for fitting both models are different from those used by Brenner and Sachs, in particular taking account of the covariance structure, which they did not, and omitting certain unjustifiable adjustments to the miner data. The fit of the original model of Brenner and Sachs (with 0 y period of latency) is generally poor, although it is much improved by assuming a 5 or 6 y period of latency from the first appearance of a pre-malignant cell to cancer. The fit of this latter model is equivalent to that of a linear relative risk model with adjustment for age at exposure and attained age. In particular, both models are capable of describing the observed inverse dose rate effect in this data set

  2. Comparison of conversion coefficients for equivalent dose in terms of air kerma using a sitting and standing female adult voxel simulators exposure to photons in antero-posterior irradiation geometry

    International Nuclear Information System (INIS)

    Cavalcante, F.R.; Galeano, D.C.; Carvalho Júnior, A.B.; Hunt, J.

    2014-01-01

    Due to the difficulty in implementing invasive techniques for calculations of dose for some exposure scenarios, computational simulators have been created to represent as realistically as possible the structures of the human body and through radiation transport simulations to obtain conversion coefficients (CCs) to estimate dose. In most published papers simulators are implemented in the standing posture and this may not describe a real scenario of exposure. In this work we developed exposure scenarios in the Visual Monte Carlo (VMC) code using a female simulator in standing and sitting postures. The simulator was irradiated in the antero-posterior (AP) geometry by a plane source of monoenergetic photons with energy from 10 keV to 2 MeV. The conversion coefficients for equivalent dose in terms of air kerma (H T /K air ) were calculated for both scenarios and compared. The results show that the percentage difference of CCs for the organs of the head and thorax was not significant (less than 5%) since the anatomic position of the organs is the same in both postures. The percentage difference is more significant to the ovaries (71% for photon energy of 20 keV), to the bladder (39% at 60 keV) and to the uterus (37% at 100 keV) due to different processes of radiation interactions in the legs of the simulator when its posture is changed. For organs and tissues that are distributed throughout the entire body, such as bone (21% at 100 keV) and muscle (30% at 80 keV) the percentage difference of CCs reflects a reduction of interaction of photons with the legs of the simulator. Therefore, the calculation of conversion coefficients using simulators in the sitting posture is relevant for a more accurate dose estimation in real exposures to radiation. - Highlights: ► Scenarios of external photon exposures were performed in VMC code. ► The FAX simulator was irradiated in sitting and standing postures. ► The irradiation geometry used was the antero-posterior (AP). ► The

  3. La caféine : esquisse d'une histoire phytochimique

    OpenAIRE

    Jaussaud, Philippe

    2016-01-01

    article électronique déposé sur le blog Interfaces/Livres anciens de l'Université de Lyonhttp://bibulyon.hypotheses.org/6616; Présente dans les trois boissons chaudes habituellement associées à nos petits-déjeuners - café, thé et chocolat -, la caféine est une méthylxanthine. Elle existe dans des plantes taxinomiquement très variées, comme : le Caféier (Coffea arabica, Coffea canefora, etc.), le Maté (Ilex paraguariensis), le Guarana (Paullinia cupana), le Théier (Camellia sinensis), le Kolat...

  4. Evaluation of operational incidents in the research reactor RP-10 according to scale INES

    International Nuclear Information System (INIS)

    Arrieta, Rolando W.B.; Vela Mora, Mariano

    2013-01-01

    This report presents the evaluation of the events in 2011 in the RP-10 Nuclear Reactor Nuclear Center Huarangal from the point of view of safety. To classify these events produced is used Scale International Nuclear and Radiological Event Scale (INES) to facilitate a common understanding between the technical community, the media and the general public. From the results we can say that in 2011 all related to security events that occurred in the RP -10 are classified as 'below scale' or no safety significance. (author)

  5. Homocyst(e)ine metabolism in hemodialysis patients treated with vitamins B6, B12 and folate.

    Science.gov (United States)

    Henning, B F; Zidek, W; Riezler, R; Graefe, U; Tepel, M

    2001-03-01

    Hyperhomocyst(e)inemia is commonly accepted as an independent atherosclerotic risk factor. In most hemodialysis patients, serum homocyst(e)ine is markedly elevated and may contribute to premature atherosclerosis in these patients. Whereas the beneficial effect of folate supplementation on serum homocyst(e)ine has been extensively studied, there are less detailed studies on the effects of cobalamin and pyridoxal phosphate alone, or in combination with folate. We examined the effect of a four-week course of intravenous treatment with folate (1.1 mg), cobalamin (1.0 mg), and pyridoxal phosphate (5.0 mg), administered once (group 1), twice (group 2) or thrice (group 3) weekly in 33 hemodialysis patients divided in three groups of 11 patients. All patients were followed for a further four weeks after treatment was stopped. Serum homocyst(e)ine, cobalamin, folate and pyridoxal phosphate, as well as the metabolites of homocyst(e)ine, methylmalonate, 2-methylcitrate and cystathionine, were determined before, during and after treatment. Baseline serum homocyst(e)ine correlated significantly with serum folate (P=0.0149), cobalamin (P=0.0047) and pyridoxal phosphate (P=0.0408). Correlations independent from the other metabolites or vitamins were found for methylmalonate (P=0.003) and folate (P=0.029). All regimens increased serum cobalamin significantly (in group 1 from 444 +/- 215 to 17,303 +/- 11,989 pg/ml, Pine was lowered significantly by 39.8% +/- 31.9% (Pine levels. Increasing cobalamin levels and additional treatment with folate and pyridoxal phosphate 156 may decrease serum homocyst(e)ine in the same way as high doses of folate alone.

  6. Meat quality of castrated and non-castrated Santa Ines lambs subjected to food restriction

    Directory of Open Access Journals (Sweden)

    Dayanne Lima de Sousa

    2016-06-01

    Full Text Available This study aimed to evaluate the quality of meat of castrated and non-castrated Santa Ines lambs submitted to food restriction. Were used 30 lambs, 15 castrated and 15 non-castrated, about two months of age and average initial body weight of 13.00 ± 1.49 kg. The lambs were distributed in a completely randomized design in a factorial arrangement 3 x 2 (restriction level x sex class, according to the amount of food provided. The duration of the experiment was determined by the time required for the animals in the one of the groups achieved 28 kg of body weight. There was interaction between food restriction levels and sex class to the variables intensity of yellow color and pH in the longissimus lumborum muscle and the shear force in the semimembranosus muscle. In non-castrated animals, the intensity of yellow color was higher in the longissimus lumborum muscle at the level of 30% of food restriction. There was no significant interaction between food restriction levels and sex class for the quality aspects related to color saturation, color tone, luminosity, red intensity, water holding capacity and cooking losses in longissimus lumborum and semimembranosus muscles. Although food restriction and sex class have influenced the variables related to the quality of meat of the animals evaluated, the mean values are considered acceptable by the literature. The feeding restriction levels and sex class influence some important features of quality of Santa Ines lamb meat.

  7. Supplementation of diets for Santa Ines sheep with organic and inorganic zinc sources

    Directory of Open Access Journals (Sweden)

    Flávio Garcia Vilela

    2012-09-01

    Full Text Available This research was conducted with objective to evaluate the effect of different zinc (Zn sources and doses in the diet for Santa Ines sheep. Forty lambs at weaning, with 18.4 kg of body weight were supplemented with three different sources of zinc (zinc oxide (ZnO, zinc amino acid and zinc proteinate and three doses of zinc (200, 400 and 600 mg/kg DM added to the basal diet. At every 28 days, animals were weighted and blood samples were collected for analyses of zinc (Zn, alkaline phosphatase and immunoglobulin G (IgG and M (IgM. At the end of experiment, liver samples were collected for determination of the hepatic zinc levels. Zinc was analyzed with atomic absorption spectrophotometer, while phosphatase alkaline and immunoglobulins G and M were analyzed using Laborlab and Bioclin kits, respectively. There was no effect of diets on phosphatase alkaline levels and hepatic zinc, but there was difference in the plasmatic zinc levels and IgG and IgM levels. Based on the accumulation of hepatic zinc, the estimate of the zinc bioavailability, through the regression equation, showed that supplementation with organic and inorganic sources of zinc did not differ in the diet of Santa Ines sheep.

  8. Ingestive Behavior and Nitrogen Balance of Confined Santa Ines Lambs Fed Diets Containing Soybean Hulls

    Directory of Open Access Journals (Sweden)

    Milena Patrícia Viana Bastos

    2014-01-01

    Full Text Available The objective of this study was to assess the effect of substituting corn with soybean hulls on the ingestive behavior and nitrogen balance of Santa Ines lambs. A total of 25 lambs with an initial body weight of 20±2 kg at approximately six months of age, sheltered individually in stalls (1.10 m×1.0 m, considering an entirely casual experimental delineation. Soybean hulls were substituted for corn at 0, 250, 500, 750, and 1,000 g/kg of dry matter (DM. The time spent feeding, ruminating, masticating, and resting was not affected by the substitution of corn with soybean hulls. In fact, the feeding efficiency in g DM/h and the rumination efficiency in g DM/bolus increased linearly with soybean hull substitution in the feed. Although the nitrogen balance was not altered by the use of soybean hulls as a substitute for corn in the diets of Santa Ines lambs, the N ingested and N digested expressed in g/d, N retained as a percentage of that ingested, and N retained as a percentage of that digested displayed quadratic behavior. In conclusion, corn can be substituted with soybean hulls up to 1,000 g/kg of dry matter in the concentrate, without changing the ingestive behavior and nitrogen balance.

  9. Ingestive behavior and nitrogen balance of confined santa ines lambs fed diets containing soybean hulls.

    Science.gov (United States)

    Bastos, Milena Patrícia Viana; de Carvalho, Gleidson Giordano Pinto; Pires, Aureliano José Vieira; Silva, Robério Rodrigues; Filho, Antônio Eustáquio; Dos Santos, Edileusa de Jesus; Chagas, Daiane Maria Trindade; Barroso, Daniele Soares; Filho, George Abreu

    2014-01-01

    The objective of this study was to assess the effect of substituting corn with soybean hulls on the ingestive behavior and nitrogen balance of Santa Ines lambs. A total of 25 lambs with an initial body weight of 20±2 kg at approximately six months of age, sheltered individually in stalls (1.10 m×1.0 m), considering an entirely casual experimental delineation. Soybean hulls were substituted for corn at 0, 250, 500, 750, and 1,000 g/kg of dry matter (DM). The time spent feeding, ruminating, masticating, and resting was not affected by the substitution of corn with soybean hulls. In fact, the feeding efficiency in g DM/h and the rumination efficiency in g DM/bolus increased linearly with soybean hull substitution in the feed. Although the nitrogen balance was not altered by the use of soybean hulls as a substitute for corn in the diets of Santa Ines lambs, the N ingested and N digested expressed in g/d, N retained as a percentage of that ingested, and N retained as a percentage of that digested displayed quadratic behavior. In conclusion, corn can be substituted with soybean hulls up to 1,000 g/kg of dry matter in the concentrate, without changing the ingestive behavior and nitrogen balance.

  10. Effective dose equivalent

    International Nuclear Information System (INIS)

    Huyskens, C.J.; Passchier, W.F.

    1988-01-01

    The effective dose equivalent is a quantity which is used in the daily practice of radiation protection as well as in the radiation hygienic rules as measure for the health risks. In this contribution it is worked out upon which assumptions this quantity is based and in which cases the effective dose equivalent can be used more or less well. (H.W.)

  11. Characterization of revenue equivalence

    NARCIS (Netherlands)

    Heydenreich, B.; Müller, R.; Uetz, Marc Jochen; Vohra, R.

    2009-01-01

    The property of an allocation rule to be implementable in dominant strategies by a unique payment scheme is called revenue equivalence. We give a characterization of revenue equivalence based on a graph theoretic interpretation of the incentive compatibility constraints. The characterization holds

  12. Characterization of Revenue Equivalence

    NARCIS (Netherlands)

    Heydenreich, Birgit; Müller, Rudolf; Uetz, Marc Jochen; Vohra, Rakesh

    2008-01-01

    The property of an allocation rule to be implementable in dominant strategies by a unique payment scheme is called \\emph{revenue equivalence}. In this paper we give a characterization of revenue equivalence based on a graph theoretic interpretation of the incentive compatibility constraints. The

  13. On the operator equivalents

    International Nuclear Information System (INIS)

    Grenet, G.; Kibler, M.

    1978-06-01

    A closed polynomial formula for the qth component of the diagonal operator equivalent of order k is derived in terms of angular momentum operators. The interest in various fields of molecular and solid state physics of using such a formula in connection with symmetry adapted operator equivalents is outlined

  14. Equivalent Dynamic Models.

    Science.gov (United States)

    Molenaar, Peter C M

    2017-01-01

    Equivalences of two classes of dynamic models for weakly stationary multivariate time series are discussed: dynamic factor models and autoregressive models. It is shown that exploratory dynamic factor models can be rotated, yielding an infinite set of equivalent solutions for any observed series. It also is shown that dynamic factor models with lagged factor loadings are not equivalent to the currently popular state-space models, and that restriction of attention to the latter type of models may yield invalid results. The known equivalent vector autoregressive model types, standard and structural, are given a new interpretation in which they are conceived of as the extremes of an innovating type of hybrid vector autoregressive models. It is shown that consideration of hybrid models solves many problems, in particular with Granger causality testing.

  15. Mutations du gène d'apoprotéine B100 au cours des dyslipidémies ...

    African Journals Online (AJOL)

    2 Centre de Diagnostic et de Recherche sur le SIDA et les autres Maladies Infectieuses, CHU ... d'Apolipoprotéine B100 chez les personnes vivant avec le VIH (PV-VIH) présentant une dyslipidémie. .... d'ions par la technique du kit Qiagen®.

  16. Psychometric properties of the Korean version of the incivility in nursing education-revised (INE-R) survey.

    Science.gov (United States)

    De Gagne, Jennie C; Kang, Hee Sun; Hyun, Myung Sun

    2016-12-01

    In this study, we developed and tested the psychometric properties of a translated and culturally adapted Korean version of the Incivility in Nursing Education-Revised (INE-R) survey. Using a cross-sectional design, the INE-R was administered to a convenience sample of 284 students enrolled in three Korean nursing colleges. Descriptive statistics were calculated for 24 student and 24 faculty incivility behavior items. Underlying factor structure was examined using exploratory and confirmatory factor analyses, and model fit was assessed using chi-square goodness-of-fit and other fit indices. For student incivility items, a four-factor model provided the best fit for the data, while a two-factor model provided the best fit for faculty incivility items. Overall reliability of the INE-R for student and faculty incivility behavior was estimated as α = 0.94 and 0.96, respectively. The Korean version of the INE-R is a reliable measure for assessing perceptions of student and faculty incivility among Korean nursing students. © 2016 John Wiley & Sons Australia, Ltd.

  17. Homocyst(e)ine and coronary heart disease: pharmacoeconomic support for interventions to lower hyperhomocyst(e)inaemia.

    Science.gov (United States)

    Nallamothu, Brahmajee K; Fendrick, A Mark; Omenn, Gilbert S

    2002-01-01

    Homocyst(e)ine, a sulphur-containing amino acid, is an intermediate formed during the metabolism of the essential amino acid methionine. Biological and epidemiological evidence suggest that elevated plasma levels of homocyst(e)ine are a risk factor for atherosclerosis and coronary heart disease (CHD). In the general US population, hyperhomocyst(e)inaemia is common and most often due to mild nutritional deficiencies in the B vitamins (folic acid, vitamin B(12) and vitamin B(6)). While high homocyst(e)ine levels can be effectively lowered using folic acid and other B vitamins, it is unknown whether such vitamin therapy will lead to clinical benefits. Given that strategies for homocyst(e)ine-lowering are safe and inexpensive, however, even small reductions in CHD risk will be highly cost effective. Thus, it may be prudent for patients to ensure an adequate daily intake of dietary folic acid and other B vitamins and for physicians to screen high-risk adults such as those with established CHD as we await definitive results from ongoing clinical trials.

  18. Dose equivalent distributions in the AAEC total body nitrogen facility

    International Nuclear Information System (INIS)

    Allen, B.J.; Bailey, G.M.; McGregor, B.J.

    1985-01-01

    The incident neutron dose equivalent in the AAEC total body nitrogen facility is measured by a calibrated remmeter. Dose equivalent rates and distributions are calculated by Monte Carlo techniques which take account of the secondary neutron flux from the collimator. Experiment and calculation are found to be in satisfactory agreement. The effective dose equivalent per exposure is determined by weighting organ doses, and the potential detriment per exposure is calculated from ICRP risk factors

  19. Report of the 1997 annual meeting of the INES national officers. Working material

    International Nuclear Information System (INIS)

    1997-01-01

    Fifty nine countries are now formally participating in the use of INES. This includes all member countries who operate power reactors. Representatives of 35 countries attended the 1997 TCM. Overall, it was judged that the use of the scale was proceeding well without major technical problems in its application. Generally, public and media understanding of the scale was improving, although progress in some countries in this respect was greater than in others. A major theme of the TCM was that technical development of the scale has generally reached a satisfactory state. Further major effort should not be invested in seeking marginal improvements although the need to make some further improvements in specific areas (e.g. transport was recognized). The main area on which to concentrate effort in future was its use as a prompt and effective tool for communication

  20. COE-INES report on research and education activities. Final report

    International Nuclear Information System (INIS)

    2008-03-01

    Research and education activities on innovative nuclear energy systems to solve safety, radioactive waste and proliferation problems simultaneously, were summarized as a final report of COE-INES program. CANDLE (Constant Axial shape of Neutron flux, nuclide densities and power shape During Life of Energy producing reactor), lead-bismuth cooled fast reactors, small long-life reactors and water-cooled thorium breeding reactors were studies as innovative nuclear reactors. Experimental study of hydrogen system with carbon dioxide zero emission was progressed. Basic research on micro/nano-scale separation/transmutation of actinide nuclides and long-life fission products was conducted. Research on nuclear energy and social involvement was also conducted. (J.P.N.)

  1. A new fatal case of pyridox(am)ine 5'-phosphate oxidase (PNPO) deficiency.

    Science.gov (United States)

    Ruiz, Angeles; García-Villoria, Judit; Ormazabal, Aida; Zschocke, Johannes; Fiol, Miquel; Navarro-Sastre, Aleix; Artuch, Rafael; Vilaseca, Maria Antonia; Ribes, Antonia

    2008-02-01

    We present a patient with severe pyridox(am)ine 5'-phosphate oxidase deficiency and homozygosity for a novel nonsense-mutation, p.A174X, in the PNPO gene who died with pyridoxal phosphate (PLP) treatment despite initial clinical recovery. He presented neonatally, with the classical clinical symptoms of the disease. Increase of urinary vanillactate was the first biochemical factor of alert. Amino acid and neurotransmitter analysis in CSF indicated reduced activity of several PLP-dependent enzymes. The diagnosis was confirmed by mutational studies. From this and the other reported patients it may be concluded that the administration of PLP should not be delayed until the complete biochemical evidence is obtained.

  2. Evaluation of carcass and muscle traits in Santa Ines female lambs finished with different agricultural products

    Directory of Open Access Journals (Sweden)

    A.M. Menezes

    Full Text Available ABSTRACT The aim of this study was to evaluate the effect of different agricultural products on quantitative aspects of carcass, body constituents, cooking loss, shear force and colorimetry of the Longissimus lumborum and Triceps brachii muscles in Santa Ines lambs. 24 Santa Ines female lambs received one of four diets which were isoproteic and isoenergetic with fixed levels of forage (60% and concentrate (40% of corn and soybean meal during 45 days. The forages per diet differed: coast-cross hay (HAY, cassava hay (CASS, dehydrated by-product of pea crop (PEA and sugarcane (SC. The average weight of the lambs at the beginning of the experiment was 26.35kg. Animals were slaughtered in a federally certified abattoir. Initial and final pH, cooking losses, color using the CIELAB system, shear force and the quantity of sarcomeres per 100μm were measured. Hot carcass, cold and half carcass weights were affected by treatments (P<0.05. The sarcomere length of Triceps brachii muscle 24 hours after slaughter differed between diets and coast-cross hay had the lowest value. The sarcomere length differed significantly between diets and the dehydrated by-product of pea crop had the lowest number of sarcomeres immediately after slaughter compared to other diets. There was no influence of diet on colorimetry, cooking loss and shear force. The decrease in pH followed the development of the process of rigor mortis in the Longissimus lumborum and Triceps brachii muscles in the first hour and up to 24 hours after slaughter. Diets did not alter the pH, water holding capacity, colorimetry or shear force. The pea by-product and sugarcane can replace traditional sources of fodder without depreciation of meat characteristics.

  3. Research and development activities at INE concerning corrosion of final repository container materials; F and E-Arbeiten zur Korrosion von Endlager-Behaelterwerkstoffen im INE

    Energy Technology Data Exchange (ETDEWEB)

    Kienzler, Bernhard

    2017-10-01

    The present work provides a historical overview of the research and development activities carried out at the (Nuclear) Research Center Karlsruhe (today KIT) since the beginning of the 1980s on the corrosion of materials which might be suitable for construction of containers for highly radioactive wastes. The report relates almost exclusively to the work performed by Dr. Emmanuel Smailos, who elaborated the corrosion of various materials at the Institute for Nuclear Waste Disposal (INE). The requirements for the containers and materials, which were subject to changes in time, are presented. The changes were strongly influenced by the changed perception of the use of nuclear energy. The selection of the materials under investigations, the boundary conditions for the corrosion experiments and the analytical methods are described. Results of the corrosion of the materials such as finegrained steel, Hastelloy C4, nodular cast iron, titanium-palladium and copper or copper-nickel alloys in typical salt solutions are summarized. The findings of special investigations, e.g. corrosion under irradiation or the influence of sulfide on the corrosion rates are shown. For construction of disposal canisters, experiments were conducted to determine the contact corrosion, the influence of the hydrogen embrittlement of Ti-Pd and fine-grained steels on the corrosion behavior as well as the corrosion behavior of welding and the influence of different welding processes with the resulting heat-affected zones on the corrosion behavior. The work was contributed to several European research programs and was well recognized in the USA. Investigations on the corrosion of steels in non-saline solutions and corrosion under interim storage conditions as well as under the expected conditions of the Konrad repository for low-level radioactive wastes are also described. In addition, the experiments on ceramic materials are presented and the results of the corrosion of Al{sub 2}O{sub 3} and Zr

  4. Establishing Substantial Equivalence: Transcriptomics

    Science.gov (United States)

    Baudo, María Marcela; Powers, Stephen J.; Mitchell, Rowan A. C.; Shewry, Peter R.

    Regulatory authorities in Western Europe require transgenic crops to be substantially equivalent to conventionally bred forms if they are to be approved for commercial production. One way to establish substantial equivalence is to compare the transcript profiles of developing grain and other tissues of transgenic and conventionally bred lines, in order to identify any unintended effects of the transformation process. We present detailed protocols for transcriptomic comparisons of developing wheat grain and leaf material, and illustrate their use by reference to our own studies of lines transformed to express additional gluten protein genes controlled by their own endosperm-specific promoters. The results show that the transgenes present in these lines (which included those encoding marker genes) did not have any significant unpredicted effects on the expression of endogenous genes and that the transgenic plants were therefore substantially equivalent to the corresponding parental lines.

  5. High plasma homocyst(e)ine levels in elderly Japanese patients are associated with increased cardiovascular disease risk independently from markers of coagulation activation and endothelial cell damage.

    Science.gov (United States)

    Kario, K; Duell, P B; Matsuo, T; Sakata, T; Kato, H; Shimada, K; Miyata, T

    2001-08-01

    Elevated plasma homocyst(e)ine is a risk factor for cardiovascular disease (CVD) in many populations, but the relationship between homocyst(e)ine and CVD in Japanese subjects has been unclear. It has been hypothesized that the link between homocyst(e)ine and CVD may be mediated in part by activation of coagulation and endothelial cell injury in the elderly Japanese subjects. To further evaluate this hypothesis, the present cross-sectional study was designed to assess the relationships among plasma homocyst(e)ine concentrations, risk of CVD, and markers of coagulation (fibrinogen, FVII, F1+2, FVIIa and FXIIa) and endothelial cell damage (vWF and thrombomodulin) in 146 elderly Japanese subjects (79 healthy controls and 67 patients with CVD). The geometric mean (range) of plasma homocyst(e)ine concentrations was 10.2 (3.2--33) micromol/l in 79 Japanese healthy elderly subjects. As expected, healthy female and male elderly subjects had homocyst(e)ine levels that were 2.5 and 5.3 micromol/; higher, respectively, compared to healthy young control subjects (n=62). Healthy young and elderly men had homocyst(e)ine levels that were 1.7 and 4.5 micromol/l higher, respectively, compared to values in women. This higher plasma homocyst(e)ine levels in the elderly subjects were negatively correlated with levels of folic acid, albumin and total cholesterol, but were not significantly related to markers of coagulation or endothelial cell-damage. The results of multiple logistic regression analyses suggested that high homocyst(e)ine levels were independently related to CVD risk. In addition, levels of FVIIa, and F1+2 were significantly higher in elderly Japanese patients with CVD compared to elderly subjects without CVD, but were unrelated to plasma homocyst(e)ine concentrations. In summary, elevated plasma concentrations of homocyst(e)ine, FVIIa, and F1+2 were associated with increased risk of CVD in elderly male and female Japanese subjects, but the association between homocyst(e)ine

  6. The principle of equivalence

    International Nuclear Information System (INIS)

    Unnikrishnan, C.S.

    1994-01-01

    Principle of equivalence was the fundamental guiding principle in the formulation of the general theory of relativity. What are its key elements? What are the empirical observations which establish it? What is its relevance to some new experiments? These questions are discussed in this article. (author). 11 refs., 5 figs

  7. Radioactive waste equivalence

    International Nuclear Information System (INIS)

    Orlowski, S.; Schaller, K.H.

    1990-01-01

    The report reviews, for the Member States of the European Community, possible situations in which an equivalence concept for radioactive waste may be used, analyses the various factors involved, and suggests guidelines for the implementation of such a concept. Only safety and technical aspects are covered. Other aspects such as commercial ones are excluded. Situations where the need for an equivalence concept has been identified are processes where impurities are added as a consequence of the treatment and conditioning process, the substitution of wastes from similar waste streams due to the treatment process, and exchange of waste belonging to different waste categories. The analysis of factors involved and possible ways for equivalence evaluation, taking into account in particular the chemical, physical and radiological characteristics of the waste package, and the potential risks of the waste form, shows that no simple all-encompassing equivalence formula may be derived. Consequently, a step-by-step approach is suggested, which avoids complex evaluations in the case of simple exchanges

  8. Equivalent Colorings with "Maple"

    Science.gov (United States)

    Cecil, David R.; Wang, Rongdong

    2005-01-01

    Many counting problems can be modeled as "colorings" and solved by considering symmetries and Polya's cycle index polynomial. This paper presents a "Maple 7" program link http://users.tamuk.edu/kfdrc00/ that, given Polya's cycle index polynomial, determines all possible associated colorings and their partitioning into equivalence classes. These…

  9. Correspondences. Equivalence relations

    International Nuclear Information System (INIS)

    Bouligand, G.M.

    1978-03-01

    We comment on sections paragraph 3 'Correspondences' and paragraph 6 'Equivalence Relations' in chapter II of 'Elements de mathematique' by N. Bourbaki in order to simplify their comprehension. Paragraph 3 exposes the ideas of a graph, correspondence and map or of function, and their composition laws. We draw attention to the following points: 1) Adopting the convention of writting from left to right, the composition law for two correspondences (A,F,B), (U,G,V) of graphs F, G is written in full generality (A,F,B)o(U,G,V) = (A,FoG,V). It is not therefore assumed that the co-domain B of the first correspondence is identical to the domain U of the second (EII.13 D.7), (1970). 2) The axiom of choice consists of creating the Hilbert terms from the only relations admitting a graph. 3) The statement of the existence theorem of a function h such that f = goh, where f and g are two given maps having the same domain (of definition), is completed if h is more precisely an injection. Paragraph 6 considers the generalisation of equality: First, by 'the equivalence relation associated with a map f of a set E identical to (x is a member of the set E and y is a member of the set E and x:f = y:f). Consequently, every relation R(x,y) which is equivalent to this is an equivalence relation in E (symmetrical, transitive, reflexive); then R admits a graph included in E x E, etc. Secondly, by means of the Hilbert term of a relation R submitted to the equivalence. In this last case, if R(x,y) is separately collectivizing in x and y, theta(x) is not the class of objects equivalent to x for R (EII.47.9), (1970). The interest of bringing together these two subjects, apart from this logical order, resides also in the fact that the theorem mentioned in 3) can be expressed by means of the equivalence relations associated with the functions f and g. The solutions of the examples proposed reveal their simplicity [fr

  10. Occupational dose equivalent limits

    International Nuclear Information System (INIS)

    Goldfinch, E.P.

    1980-01-01

    This paper considers methods of limiting individual radiation risks by recognizing the variation of risk with age at exposure, taking into account both somatic and genetic risks and proposes a simple formula for controlling individual cumulative exposure and hence risk. (Author)

  11. Geology of the Curimatau medium region (Paraiba State, Brazil) and the emplacement of the Dona Ines granite associated to the Brasiliano transcurrent shear zones

    International Nuclear Information System (INIS)

    Borges, Sergio Vieira Freire

    1996-01-01

    In an area of about 700 Km 2 located in the northeast of Paraiba State and having as main point the town of Dona Ines, a geologic/structural mapping, a gravimetric survey and radiometric dating using the Rb/Sr method in whole rock and Sm.Nd model ages were undertaken in order to study and to understand the geology of this portion of terrain, the emplacement of the Dona Ines granitoids and its relationship with the enclosing rocks and the deformation acting at the time of the intrusion. The age of the pluton of Dona Ines was determined by the Rb/Sr whole rock method as 560 ± 20 Ma (end of Brasiliano Cycle in the region). Sm.Nd model ages in granitoids of Araras, Belem and Dona Ines have revealed paleoproterozoic ages for their crustal sources, as indicated by the negative ε nd of this rock

  12. The equivalence theorem

    International Nuclear Information System (INIS)

    Veltman, H.

    1990-01-01

    The equivalence theorem states that, at an energy E much larger than the vector-boson mass M, the leading order of the amplitude with longitudinally polarized vector bosons on mass shell is given by the amplitude in which these vector bosons are replaced by the corresponding Higgs ghosts. We prove the equivalence theorem and show its validity in every order in perturbation theory. We first derive the renormalized Ward identities by using the diagrammatic method. Only the Feynman-- 't Hooft gauge is discussed. The last step of the proof includes the power-counting method evaluated in the large-Higgs-boson-mass limit, needed to estimate the leading energy behavior of the amplitudes involved. We derive expressions for the amplitudes involving longitudinally polarized vector bosons for all orders in perturbation theory. The fermion mass has not been neglected and everything is evaluated in the region m f ∼M much-lt E much-lt m Higgs

  13. Asymmetric dimethyl-L-arginine (ADMA): a possible link between homocyst(e)ine and endothelial dysfunction.

    Science.gov (United States)

    Stühlinger, Markus C; Stanger, Olaf

    2005-02-01

    Hyperhomocyst(e)inemia is associated with an increased risk for atherosclerotic disease and venous thromboembolism. The impact of elevated plasma homocysteine levels seems to be clinically relevant, since the total cardiovascular risk of hyperhomocyst(e)inemia is comparable to the risk associated with hyperlipidemia or smoking. There is substantial evidence for impairment of endothelial function in human and animal models of atherosclerosis, occurring even before development of overt plaques. Interestingly endothelial dysfunction appears to be a sensitive indicator of the process of atherosclerotic lesion development and predicts future vascular events. NO is the most potent endogenous vasodilator known. It is released by the endothelium, and reduced NO bioavailability is responsible for impaired endothelium-dependent vasorelaxation in hyperhomocyst(e)inemia and other metabolic disorders associated with vascular disease. Substances leading to impaired endothelial function as a consequence of reduced NO generation are endogenous NO synthase inhibitors such as ADMA. Indeed there is accumulating evidence from animal and human studies that ADMA, endothelial function and homocyst(e)ine might be closely interrelated. Specifically elevations of ADMA associated with impaired endothelium-dependent relaxation were found in chronic hyperhomocyst(e)inemia, as well as after acute elevation of plasma homocyst(e)ine following oral methionine intake. The postulated mechanisms for ADMA accumulation are increased methylation of arginine residues within proteins, as well as reduced metabolism of ADMA by the enzyme DDAH, but they still need to be confirmed to be operative in vivo. Hyperhomocyst(e)inemia, as well as subsequent endothelial dysfunction can be successfully treated by application of folate and B vitamins. Since ADMA seems to play a central role in homocyst(e)ine-induced endothelial dysfunction, another way of preventing vascular disease in patients with elevated homocyst(e)ine

  14. Tyrosinase inhibition due to interaction of homocyst(e)ine with copper: the mechanism for reversible hypopigmentation in homocystinuria due to cystathionine beta-synthase deficiency.

    Science.gov (United States)

    Reish, O; Townsend, D; Berry, S A; Tsai, M Y; King, R A

    1995-01-01

    Deficiency of cystathionine beta-synthase (CBS) is a genetic disorder of transsulfuration resulting in elevated plasma homocyst(e)ine and methionine and decreased cysteine. Affected patients have multisystem involvement, which may include light skin and hair. Reversible hypopigmentation in treated homocystinuric patients has been infrequently reported, and the mechanism is undefined. Two CBS-deficient homocystinuric patients manifested darkening of their hypopigmented hair following treatment that decreased plasma homocyst(e)ine. We hypothesized that homocyst(e)ine inhibits tyrosinase, the major pigment enzyme. The activity of tyrosinase extracted from pigmented human melanoma cells (MNT-1) that were grown in the presence of homocysteine was reduced in comparison to that extracted from cells grown without homocysteine. Copper sulfate restored homocyst(e)ine-inhibited tyrosinase activity when added to the culture cell media at a proportion of 1.25 mol of copper sulfate per 1 mol of DL-homocysteine. Holo-tyrosinase activity was inhibited by adding DL-homocysteine to the assay reaction mixture, and the addition of copper sulfate to the reaction mixture prevented this inhibition. Other tested compounds, L-cystine and betaine did not affect tyrosinase activity. Our data suggest that reversible hypopigmentation in homocystinuria is the result of tyrosinase inhibition by homocyst(e)ine and that the probable mechanism of this inhibition is the interaction of homocyst(e)ine with copper at the active site of tyrosinase. Images Figure 1 PMID:7611281

  15. Increased plasma homocyst(e)ine after withdrawal of ready-to-eat breakfast cereal from the diet: prevention by breakfast cereal providing 200 microg folic acid.

    Science.gov (United States)

    Malinow, M R; Duell, P B; Irvin-Jones, A; Upson, B M; Graf, E E

    2000-08-01

    We tested the hypothesis that cessation of habitual ingestion of breakfast cereals would be associated with elevated plasma homocyst(e)ine concentrations. We anticipated that those subjects who reported consuming breakfast cereals containing 100 to 400 ,microg of folic acid per serving before entering the study would achieve higher plasma homocyst(e)ine concentrations if, in addition to their regular diet, they began ingesting a daily serving of breakfast cereal that contained less than 10 microg of folic acid per serving. Seventy-nine subjects consumed a daily serving of breakfast cereal containing either ine elevation. Breakfast cereal containing 200 microg folic acid per day was sufficient to maintain the homocyst(e)ine lowering effects of commercial cereals. Habitual consumption of commercially available fortified breakfast cereals, usually containing 100 to 400 microg folic acid per serving, had significant homocyst(e)ine lowering effects as shown by the homocyst(e)ine increase after cessation of habitual intake of commercial breakfast cereal. Substitution of breakfast cereal containing only 200 microg folic acid per day was sufficient to maintain the homocyst(e)inelowering effects of commercial cereals.

  16. Institute of Nuclear Waste Management Technology (INE). 1994 progress report on research and development

    International Nuclear Information System (INIS)

    1995-01-01

    In 1994 INE worked on the following research projects: radionuclide behaviour during corrosion of high-level radioactive COGEMA glass; studies of glassy basalt of the Werra-Fulda salt deposit as a natural analogue of the corrosion of HAW glass; corrosion studies of high burnup LWR fuels in brine; chemical behaviour of Tc in aqueous, chloride systems; corrosion studies of waste container materials; solution chemistry of U; thermodynamics of Np(V) in concentrated brines; radiation-chemical effects in the vicinity of repositories; laser spectroscopic speciation and thermodynamics of Cm(III); development of laser spectroscopic methods; radiochemical and chemical analyses of nuclear samples; solid-state and surface analyses; coupling of transport and speciation models; influence of colloid formation on the migration behaviour of long-lived radionuclides; studies of the consolidation behaviour of filling material; thermomechanical effects of inhomogeneities in the salt dome; basic studies and process engineering developments in the field of solidification of high-level radioactive fission product solutions; corrosion behaviour of WAK-HAW containing glass products in brines. (orig./HP) [de

  17. Neutron diffraction measurements at the INES diffractometer using a neutron radiative capture based counting technique

    Energy Technology Data Exchange (ETDEWEB)

    Festa, G. [Centro NAST, Universita degli Studi di Roma Tor Vergata, Roma (Italy); Pietropaolo, A., E-mail: antonino.pietropaolo@roma2.infn.it [Centro NAST, Universita degli Studi di Roma Tor Vergata, Roma (Italy); Grazzi, F.; Barzagli, E. [CNR-ISC Firenze (Italy); Scherillo, A. [CNR-ISC Firenze (Italy); ISIS facility Rutherford Appleton Laboratory (United Kingdom); Schooneveld, E.M. [ISIS facility Rutherford Appleton Laboratory (United Kingdom)

    2011-10-21

    The global shortage of {sup 3}He gas is an issue to be addressed in neutron detection. In the context of the research and development activity related to the replacement of {sup 3}He for neutron counting systems, neutron diffraction measurements performed on the INES beam line at the ISIS pulsed spallation neutron source are presented. For these measurements two different neutron counting devices have been used: a 20 bar pressure squashed {sup 3}He tube and a Yttrium-Aluminum-Perovskite scintillation detector. The scintillation detector was coupled to a cadmium sheet that registers the prompt radiative capture gamma rays generated by the (n,{gamma}) nuclear reactions occurring in cadmium. The assessment of the scintillator based counting system was done by performing a Rietveld refinement analysis on the diffraction pattern from an ancient Japanese blade and comparing the results with those obtained by a {sup 3}He tube placed at the same angular position. The results obtained demonstrate the considerable potential of the proposed counting approach based on the radiative capture gamma rays at spallation neutron sources.

  18. Changes in plasma homocyst(e)ine in the acute phase after stroke.

    Science.gov (United States)

    Howard, Virginia J; Sides, Elizabeth G; Newman, George C; Cohen, Stanley N; Howard, George; Malinow, M Rene; Toole, James F

    2002-02-01

    Elevated plasma homocyst(e)ine [H(e)] concentration has been associated with an increased risk of stroke. Although the literature suggests that H(e) increases from the acute to the convalescent phase after a stroke, it is not known whether H(e) changes within the acute period. A prospective, multicenter study was conducted to examine changes in H(e) during the 2 weeks after an incident stroke. Blood samples were collected at days 1, 3, 5, 7, and between 10 and 14 days after the stroke. Seventy-six participants (51 men) were enrolled from 9 sites from February 1997 through June 1998. Mean age was 65.6 years, and subjects had at least two H(e) measurements. The estimated mean H(e) level at baseline was 11.3+/-0.5 micromol/L, which increased consistently to a mean of 12.0+/-0.05, 12.4+/-0.5, 13.3+/-0.5, and 13.7+/-0.7 micromol/L at days 3, 5, 7, and 10 to 14, respectively. The magnitude of the change in H(e) was not affected by age, sex, smoking status, alcohol use, history of hypertension or diabetes, or Rankin Scale Score. ; These data suggest that the clinical interpretation of H(e) after stroke and the eligibility for clinical trials assessing treatment for elevated H(e) levels require an adjustment in time since stroke to properly interpret the observed H(e) levels.

  19. Equivalence, commensurability, value

    DEFF Research Database (Denmark)

    Albertsen, Niels

    2017-01-01

    Deriving value in Capital Marx uses three commensurability arguments (CA1-3). CA1 establishes equivalence in exchange as exchangeability with the same third commodity. CA2 establishes value as common denominator in commodities: embodied abstract labour. CA3 establishes value substance...... as commonality of labour: physiological labour. Tensions between these logics have permeated Marxist interpretations of value. Some have supported value as embodied labour (CA2, 3), others a monetary theory of value and value as ‘pure’ societal abstraction (ultimately CA1). They all are grounded in Marx....

  20. Association between high homocyst(e)ine and ischemic stroke due to large- and small-artery disease but not other etiologic subtypes of ischemic stroke.

    Science.gov (United States)

    Eikelboom, J W; Hankey, G J; Anand, S S; Lofthouse, E; Staples, N; Baker, R I

    2000-05-01

    Elevated plasma homocyst(e)ine may be a causal and modifiable risk factor for ischemic stroke, but the results of previous studies have been conflicting. One possible explanation is that homocyst(e)ine may only be associated with certain pathophysiological subtypes of ischemic stroke. We conducted a case-control study of 219 hospital cases with a first-ever ischemic stroke and 205 randomly selected community control subjects stratified by age, sex, and postal code. With the use of established criteria, cases of stroke were classified by etiologic subtype in a blinded fashion. The prevalence of conventional vascular risk factors, fasting plasma homocyst(e)ine levels, vitamin levels, and nucleotide 677 methylene tetrahydrofolate reductase (MTHFR) genotypes were determined in cases and controls. Increasing homocyst(e)ine was a strong and independent risk factor for ischemic stroke (adjusted OR 2.7, 95% CI 1.4 to 5.1 for a 5-micromol/L increase in fasting plasma homocyst(e)ine from 10 to 15 micromol/L). Compared with the lowest quartile, the highest quartile of homocyst(e)ine was associated with an adjusted OR of ischemic stroke of 2.2 (95% CI 1.1 to 4.2). Mean plasma homocyst(e)ine was significantly higher in cases of ischemic stroke due to large-artery disease (14.1 micromol/L, 95% CI 12.5 to 15.9, Pine, the upper 3 quartiles were associated with an adjusted OR of ischemic stroke due to large-artery disease of 3.0 (95% CI 0.8 to 10.8) for the second quartile, 5.6 (95% CI 1.6 to 20) for the third quartile, and 8.7 (95% CI 2.4 to 32) for the fourth quartile (P for trend=0.0005). However, despite a clear association between the TT MTHFR genotype and elevated fasting plasma homocyst(e)ine, there was no association between MTHFR genotype and ischemic stroke or subtype of ischemic stroke. There is a strong, graded association between increasing plasma homocyst(e)ine and ischemic stroke caused by large-artery atherosclerosis and, to a much lesser extent, small

  1. Biomonitoring Equivalents for interpretation of urinary fluoride.

    Science.gov (United States)

    Aylward, L L; Hays, S M; Vezina, A; Deveau, M; St-Amand, A; Nong, A

    2015-06-01

    Exposure to fluoride is widespread due to its natural occurrence in the environment and addition to drinking water and dental products for the prevention of dental caries. The potential health risks of excess fluoride exposure include aesthetically unacceptable dental fluorosis (tooth mottling) and increased skeletal fragility. Numerous organizations have conducted risk assessments and set guidance values to represent maximum recommended exposure levels as well as recommended adequate intake levels based on potential public health benefits of fluoride exposure. Biomonitoring Equivalents (BEs) are estimates of the average biomarker concentrations corresponding to such exposure guidance values. The literature on daily urinary fluoride excretion rates as a function of daily fluoride exposure was reviewed and BE values corresponding to the available US and Canadian exposure guidance values were derived for fluoride in urine. The derived BE values range from 1.1 to 2.1mg/L (1.2-2.5μg/g creatinine). Concentrations of fluoride in single urinary spot samples from individuals, even under exposure conditions consistent with the exposure guidance values, may vary from the predicted average concentrations by several-fold due to within- and across-individual variation in urinary flow and creatinine excretion rates and due to the rapid elimination kinetics of fluoride. Thus, the BE values are most appropriately applied to screen population central tendency estimates for biomarker concentrations rather than interpretation of individual spot sample concentrations. Copyright © 2015. Published by Elsevier Inc.

  2. Carcass and meat traits of Morada Nova, Santa Ines and ½ Ile de France ½ Texel lambs finished in feedlot

    Directory of Open Access Journals (Sweden)

    Juliano Issakowicz

    2014-03-01

    Full Text Available The aim of this study was to evaluate the carcass and meat traits of Morada Nova, Santa Ines and ½ Ile de France ½ Texel lambs finished in feedlot. Weight and proportion of meatcuts, measures of carcass size and color, tenderness, cooking loss and ultimate pH of meat from 10 Morada Nova, 6 Santa Ines and 10 ½ Ile de France ½ Texel were evaluated. The lambs were finished in collective pens, fed ad libitum with 50% corn silage and 50% concentrate and slaughtered at about six months old. Analysis of variance was performed by the procedure PROC GLM of SAS (SAS Inst., Inc., Cary, NC and means were compared by Tukey test at 5% significance. The Morada Nova lambs had values of 14.1 kg, 13.9 kg, 0.240 kg/cm, 56.2 cm and 35.8 cm for hot and cold carcass weight, compactness index, hip and leg circumference respectively and these values were lower (P <0.05 to values observed in Santa Ines (19.4 kg, 18.8 kg, 0.283 cm/kg, 64.6 cm and 40.0 cm and in ½ Ile de France ½ Texel (18.6 kg, 18.2 kg, 0.305 cm/kg; 65.4 cm and 41.6 cm lambs. The hot and cold carcass yield did not differ (P> 0.05 among genetic groups. The scores for conformation and fat cover were higher (P <0.05 in ½ Ile de France ½ Texel lambs (2.4 and 3.0 and the carcass length was greater in Santa Ines lambs (66.3 cm. The ½ Ile de France ½ Texel lambs had smaller (P<0.05 proportion of neck and greater of leg (9.10% and 33.1% compared to Morada Nova lambs (10.3% and 30.4% and Santa Inês (10.9% and 31.6%. The weight of shoulder, leg, rack, ribs and flank was lower (P<0.05 in Morada Nova (1.306, 2.127 kg, 0.999 kg, 0.775 kg and 0.433 kg respectively compared to Santa Inês (1.820 kg, 2.972 kg, 1.355 kg, 0.959 and 0.509 kg and ½ Ile de France ½ Texel (1.791 kg, 3.007 kg, 1.212 kg, 1.016 kg and 0.563 kg. The neck was heavier in Santa Ines (1.038 kg which differed (P <0.05 from the other genetic groups (0.725 kg for Morada Nova and 0.830 kg for ½ Ile de France x ½ Texel lambs. The ½ Ile de

  3. Waste Determination Equivalency - 12172

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, Rebecca D. [Savannah River Remediation (United States)

    2012-07-01

    by the Secretary of Energy in January of 2006 based on proposed processing techniques with the expectation that it could be revised as new processing capabilities became viable. Once signed, however, it became evident that any changes would require lengthy review and another determination signed by the Secretary of Energy. With the maturation of additional salt removal technologies and the extension of the SWPF start-up date, it becomes necessary to define 'equivalency' to the processes laid out in the original determination. For the purposes of SRS, any waste not processed through Interim Salt Processing must be processed through SWPF or an equivalent process, and therefore a clear statement of the requirements for a process to be equivalent to SWPF becomes necessary. (authors)

  4. Folic acid and homocyst(e)ine metabolic defects and the risk of placental abruption, pre-eclampsia and spontaneous pregnancy loss: A systematic review.

    Science.gov (United States)

    Ray, J G; Laskin, C A

    1999-09-01

    Placental infarction or abruption, recurrent pregnancy loss and pre-eclampsia are thought to arise due to defects within the placental vascular bed. Deficiencies of vitamin B12 and folate, or other abnormalities within the methionine-homocyst(e)ine pathway have been implicated in the development of such placental diseases. We conducted a systematic literature review to quantify the risk of placental disease in the presence of these metabolic defects. Studies were identified through OVID Medline between 1966 and February 1999. Terms relating to the measurement of vitamin B12, folic acid, methylenetetrahydrofolate reductase or homocyst(e)ine were combined with those of pre-eclampsia, placental abruption/infarction or spontaneous and habitual abortion. Human studies comprising both cases and controls and published in the English language were accepted. Their references were explored for other publications. Data were abstracted on the matching of cases with controls, the mean levels of folate, B12 or homocyst(e)ine in each group or the frequency of the homozygous state for the thermolabile variant of methylenetetrahydrofolate reductase. The definition of 'abnormal' for each exposure was noted and the presence or absence of the exposure of interest for each outcome was calculated as an absolute rate with a 95 per cent confidence interval. The crude odds ratios were calculated for each study and then pooled using a random effects model. Eighteen studies were finally included. Eight studies examined the risk of placental abruption/infarction in the presence of vitamin B12 or folate deficiency, or hyperhomocyst(e)inaemia. Folate deficiency was a prominent risk factor for placental abruption/infarction among four studies, though not statistically significant (pooled odds ratio 25.9, 95 per cent CI 0.9-736.3). Hyperhomocyst(e)inaemia was also associated with placental abruption/infarction both without (pooled odds ratio 5.3, 95 per cent CI 1.8-15.9) and with methionine

  5. Establishing Substantial Equivalence: Proteomics

    Science.gov (United States)

    Lovegrove, Alison; Salt, Louise; Shewry, Peter R.

    Wheat is a major crop in world agriculture and is consumed after processing into a range of food products. It is therefore of great importance to determine the consequences (intended and unintended) of transgenesis in wheat and whether genetically modified lines are substantially equivalent to those produced by conventional plant breeding. Proteomic analysis is one of several approaches which can be used to address these questions. Two-dimensional PAGE (2D PAGE) remains the most widely available method for proteomic analysis, but is notoriously difficult to reproduce between laboratories. We therefore describe methods which have been developed as standard operating procedures in our laboratory to ensure the reproducibility of proteomic analyses of wheat using 2D PAGE analysis of grain proteins.

  6. The transnational <i>ne bis in idem principle in the EU. Mutual recognition and equivalent protection of human rights

    Directory of Open Access Journals (Sweden)

    John A.E. Vervaele

    2005-12-01

    Full Text Available The deepening and widening of European integration has led to an increase in transborder crime. Concurrent prosecution and sanctioning by several Member States is not only a problem in inter-state relations and an obstacle in the European integration process, but also a violation of the ne bis in idem principle, defined as a transnational human right in a common judicial area. This article analyzes whether and to what extent the ECHR has contributed and may continue to contribute to the development of such a common ne bis in idem standard in Europe. It is also examined whether the application of the ne bis in idem principle in classic inter-state judicial cooperation in criminal matters in the framework of the Council of Europe may make such a contribution as well. The transnational function of the ne bis in idem principle is discussed in the light of the Court of Justice’s case law on ne bis in idem in the framework of the area of Freedom, Security and Justice. Finally the inherent tension between mutual recognition and the protection of human rights in transnational justice is analyzed by looking at the insertion of the ne bis in idem principle in the Framework Decision on the European arrest warrant.

  7. Research and development activities at INE concerning corrosion of final repository container materials

    International Nuclear Information System (INIS)

    Kienzler, Bernhard

    2017-01-01

    The present work provides a historical overview of the research and development activities carried out at the (Nuclear) Research Center Karlsruhe (today KIT) since the beginning of the 1980s on the corrosion of materials which might be suitable for construction of containers for highly radioactive wastes. The report relates almost exclusively to the work performed by Dr. Emmanuel Smailos, who elaborated the corrosion of various materials at the Institute for Nuclear Waste Disposal (INE). The requirements for the containers and materials, which were subject to changes in time, are presented. The changes were strongly influenced by the changed perception of the use of nuclear energy. The selection of the materials under investigations, the boundary conditions for the corrosion experiments and the analytical methods are described. Results of the corrosion of the materials such as finegrained steel, Hastelloy C4, nodular cast iron, titanium-palladium and copper or copper-nickel alloys in typical salt solutions are summarized. The findings of special investigations, e.g. corrosion under irradiation or the influence of sulfide on the corrosion rates are shown. For construction of disposal canisters, experiments were conducted to determine the contact corrosion, the influence of the hydrogen embrittlement of Ti-Pd and fine-grained steels on the corrosion behavior as well as the corrosion behavior of welding and the influence of different welding processes with the resulting heat-affected zones on the corrosion behavior. The work was contributed to several European research programs and was well recognized in the USA. Investigations on the corrosion of steels in non-saline solutions and corrosion under interim storage conditions as well as under the expected conditions of the Konrad repository for low-level radioactive wastes are also described. In addition, the experiments on ceramic materials are presented and the results of the corrosion of Al 2 O 3 and ZrO 2 ceramics

  8. The Effects of Muscle Mass on Homocyst(e)ine Levels in Plasma and Urine.

    Science.gov (United States)

    Malinow, M René; Lister, Craig L; DE Crée, Carl

    The present study was designed to examine the relationship between homocyst(e)ine (H[e]) levels and muscle mass. Two experimental groups each of 24 Caucasian males, one consisting of higher-muscle mass subjects (HMM) and the other of lower-muscle mass subjects (LMM) participated in this study. Muscle mass was estimated from 24-hour urine collections of creatinine (Crt). Muscle mass was 40.3 ± 15.9 kg in HMM and 37.2 ± 11.4 kg in LMM (P= 0.002). Mean plasma H(e) levels in HMM were 10.29 ± 2.9 nmol/mL, and in LMM were 10.02 ± 2.4 nmol/L (Not significant, [NS]). Urinary H(e) levels (UH[e]) were 9.95 ± 4.3 nmol/mL and 9.22 ± 2.9 nmol/mL for HMM and LMM, respectively (NS). Plasma H(e) levels correlated well with UH(e) (HMM: r= 0.58, P= 0.009; LMM: r= 0.66, P= 0.004). Muscle mass and was not correlated to either plasma H(e) or UH(e). However, in HMM trends were identified for body mass to be correlated with UH(e) (r= 0.39, P= 0.10) and UCrt (r= 0.41, P= 0.08). Surprisingly, in HMM plasma and UCrt were only weakly correlated (r= 0.44, P= 0.06). Our results do not support a causal relationship between the amount of muscle mass and H(e) levels in plasma or urine.

  9. Overexpression of cellular glutathione peroxidase rescues homocyst(e)ine-induced endothelial dysfunction

    Science.gov (United States)

    Weiss, Norbert; Zhang, Ying-Yi; Heydrick, Stanley; Bierl, Charlene; Loscalzo, Joseph

    2001-01-01

    Homocyst(e)ine (Hcy) inhibits the expression of the antioxidant enzyme cellular glutathione peroxidase (GPx-1) in vitro and in vivo, which can lead to an increase in reactive oxygen species that inactivate NO and promote endothelial dysfunction. In this study, we tested the hypothesis that overexpression of GPx-1 can restore the normal endothelial phenotype in hyperhomocyst(e)inemic states. Heterozygous cystathionine β-synthase-deficient (CBS(−/+)) mice and their wild-type littermates (CBS(+/+)) were crossbred with mice that overexpress GPx-1 [GPx-1(tg+) mice]. GPx-1 activity was 28% lower in CBS(−/+)/GPx-1(tg−) compared with CBS(+/+)/GPx-1(tg−) mice (P < 0.05), and CBS(−/+) and CBS(+/+) mice overexpressing GPx-1 had 1.5-fold higher GPx-1 activity compared with GPx-1 nontransgenic mice (P < 0.05). Mesenteric arterioles of CBS(−/+)/GPx-1(tg−) mice showed vasoconstriction to superfusion with β-methacholine and bradykinin (P < 0.001 vs. all other groups), whereas nonhyperhomocyst(e)inemic mice [CBS(+/+)/GPx-1(tg−) and CBS(+/+)/GPx-1(tg+) mice] demonstrated dose-dependent vasodilation in response to both agonists. Overexpression of GPx-1 in hyperhomocyst(e)inemic mice restored the normal endothelium-dependent vasodilator response. Bovine aortic endothelial cells (BAEC) were transiently transfected with GPx-1 and incubated with dl-homocysteine (HcyH) or l-cysteine. HcyH incubation decreased GPx-1 activity in sham-transfected BAEC (P < 0.005) but not in GPx-1-transfected cells. Nitric oxide release from BAEC was significantly decreased by HcyH but not cysteine, and GPx-1 overexpression attenuated this decrease. These findings demonstrate that overexpression of GPx-1 can compensate for the adverse effects of Hcy on endothelial function and suggest that the adverse vascular effects of Hcy are at least partly mediated by oxidative inactivation of NO. PMID:11606774

  10. Quantification of the equivalence principle

    International Nuclear Information System (INIS)

    Epstein, K.J.

    1978-01-01

    Quantitative relationships illustrate Einstein's equivalence principle, relating it to Newton's ''fictitious'' forces arising from the use of noninertial frames, and to the form of the relativistic time dilatation in local Lorentz frames. The equivalence principle can be interpreted as the equivalence of general covariance to local Lorentz covariance, in a manner which is characteristic of Riemannian and pseudo-Riemannian geometries

  11. Geology of the Curimatau medium region (Paraiba State, Brazil) and the emplacement of the Dona Ines granite associated to the Brasiliano transcurrent shear zones; Geologia da Regiao do Medio Curimatau (PB) e o alojamento do granito de Dona Ines associado a zonas de cisalhamento transcorrentes brasilianas

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Sergio Vieira Freire

    1996-12-31

    In an area of about 700 Km{sup 2} located in the northeast of Paraiba State and having as main point the town of Dona Ines, a geologic/structural mapping, a gravimetric survey and radiometric dating using the Rb/Sr method in whole rock and Sm.Nd model ages were undertaken in order to study and to understand the geology of this portion of terrain, the emplacement of the Dona Ines granitoids and its relationship with the enclosing rocks and the deformation acting at the time of the intrusion. The age of the pluton of Dona Ines was determined by the Rb/Sr whole rock method as 560 {+-} 20 Ma (end of Brasiliano Cycle in the region). Sm.Nd model ages in granitoids of Araras, Belem and Dona Ines have revealed paleoproterozoic ages for their crustal sources, as indicated by the negative {epsilon}{sub nd} of this rock 128 refs., 95 figs., 6 tabs., 7 maps

  12. Geology of the Curimatau medium region (Paraiba State, Brazil) and the emplacement of the Dona Ines granite associated to the Brasiliano transcurrent shear zones; Geologia da Regiao do Medio Curimatau (PB) e o alojamento do granito de Dona Ines associado a zonas de cisalhamento transcorrentes brasilianas

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Sergio Vieira Freire

    1997-12-31

    In an area of about 700 Km{sup 2} located in the northeast of Paraiba State and having as main point the town of Dona Ines, a geologic/structural mapping, a gravimetric survey and radiometric dating using the Rb/Sr method in whole rock and Sm.Nd model ages were undertaken in order to study and to understand the geology of this portion of terrain, the emplacement of the Dona Ines granitoids and its relationship with the enclosing rocks and the deformation acting at the time of the intrusion. The age of the pluton of Dona Ines was determined by the Rb/Sr whole rock method as 560 {+-} 20 Ma (end of Brasiliano Cycle in the region). Sm.Nd model ages in granitoids of Araras, Belem and Dona Ines have revealed paleoproterozoic ages for their crustal sources, as indicated by the negative {epsilon}{sub nd} of this rock 128 refs., 95 figs., 6 tabs., 7 maps

  13. Effects of growth hormone (GH) administration on homocyst(e)ine levels in men with GH deficiency: a randomized controlled trial.

    Science.gov (United States)

    Sesmilo, G; Biller, B M; Llevadot, J; Hayden, D; Hanson, G; Rifai, N; Klibanski, A

    2001-04-01

    GH deficiency is associated with increased cardiovascular mortality and early manifestations of atherosclerosis. Elevated serum homocyst(e)ine levels have been found to be associated with increased cardiovascular risk. The effect of GH replacement on homocyst(e)ine has not been investigated to date. We evaluated the effect of GH replacement on fasting homocyst(e)inemia in a group of men with adult-onset GH deficiency in a randomized, single blind, placebo-controlled trial. Forty men with adult-onset GH deficiency were randomized to GH or placebo for 18 months, with dose adjustments made according to serum insulin-like growth factor I (IGF-I) levels. Fasting serum homocyst(e)ine, folate, vitamin B12, and total T(3) levels were determined at baseline and 6 and 18 months. Anthropometry, IGF-I levels, insulin, and glucose were measured at 1, 3, 6, 12, and 18 months. Nutritional assessment, body composition, total T(4), thyroid hormone binding index, and free T(4) index were assessed every 6 months. Homocyst(e)ine decreased in the GH-treated group compared with that in the placebo group (net difference, -1.2 +/- 0.6 micromol/L; confidence interval, -2.4, -0.02 micromol/L; P = 0.047). Homocyst(e)ine at baseline was negatively correlated with plasma levels of folate (r = -0.41; P = 0.0087). Total T(3) increased in the GH-treated group vs. that in the placebo group (net difference, 0.17 +/- 0.046 ng/dL; confidence interval, 0.071, 0.26 nmol/L; P = 0.0012). Folate and vitamin B12 levels did not significantly change between groups. Changes in homocyst(e)ine were negatively correlated with changes in IGF-I. For each 1 nmol/L increase in IGF-I, homocyst(e)ine decreased by 0.04 +/- 0.02 micromol/L (P = 0.029). In contrast, changes in homocyst(e)ine did not correlate with changes in folate, vitamin B12, total T(3), C-reactive protein, interleukin-6, or insulin levels. This study shows that GH replacement decreases fasting homocyst(e)ine levels compared with placebo. This may be

  14. Classification of radiation-hazardous objects by the ecological risk rate, based on the concept of the International Nuclear Event Scale (INES)

    International Nuclear Information System (INIS)

    Vetrov, V.A.

    2003-01-01

    The principal categories of the radiation-hazardous objects (RHO) (nuclear fuel cycle plants (NFC including NPP); ships with nuclear engine units and appropriate service facilities; units related with nuclear weapons (design, manufacture, storage, etc.); contaminated territories in the result nuclear accidents and nuclear facilities tests; civil enterprises using the radioactive sources) with real accident risk from radioactive substances (RS) release into environment are considered. For assessment of the ecological risk rate from RHO the International Nuclear Event Scale implemented by IAEA for NPP use is suggested. By opinion of the specialists the INES criteria could be used for radiation events assessment to other RHO that gives possibility for RHO arrangement by the potential hazard rate for environment in the case of accident. For RHO qualitative classification the main parameters assessment influencing on radioactive release risk (amount (total activity) of radioactive substances; possibility of chain reaction development; strength of technological parameters, etc.) was suggested. On the base of the INES all above-listed RHO kinds in the case of accident could be conditionally separated into three categories: 1. most radiation dangerous objects, on which could be severe and serious radiation accidents (corresponding to 4-7 INES levels); 2. RHO on which there is risk for accidents accompanying with RS release (accidents up to 4 INES level). 3. RHO without practical possibility for event (incidents - not higher 3 INES level). Introduction of suggested classification gives possibility for RHO safety control requirements rationalizing to radiation monitoring purposes for both RHO and the local systems

  15. 677C to T mutation in the 5,10-methylenetetrahydrofolate reductase (MTHFR) gene and plasma homocyst(e)ine levels in patients with TIA or minor stroke.

    Science.gov (United States)

    Lalouschek, W; Aull, S; Korninger, L; Mannhalter, C; Pabinger-Fasching, I; Schmid, R W; Schnider, P; Zeiler, K

    1998-03-05

    It was the aim of this study to determine the associations of clinical and laboratory data with plasma homocyst(e)ine levels in patients with transient ischemic attack (TIA) or minor stroke (MS), with special reference to their 677C to T mutation status in the 5,10-methylenetetrahydrofolate reductase (5,10-MTHFR) gene. Seventy-six patients with TIA or MS were investigated at least 3 months after their (last) clinical event. By means of univariate analysis, significant correlations of homocyst(e)ine levels with male gender (Pine levels. After adjustment for age, creatinine levels and homocyst(e)ine levels remained significantly correlated to each other (Pine levels was no longer significant (P=0.10). Mutation-positive patients exhibited moderately and statistically non-significantly higher homocyst(e)ine levels than mutation-negative patients, particularly those who were homozygous positive. Homocyst(e)ine levels were closely correlated with creatinine levels (Pine levels in patients with TIA or MS are dependent on the 5,10-MTHFR mutation status. Significant correlations between these variables were found only in mutation-positive but not in mutation-negative patients.

  16. High plasma cyst(e)ine level may indicate poor clinical outcome in patients with acute stroke: possible involvement of hydrogen sulfide.

    Science.gov (United States)

    Wong, Peter T H; Qu, Kun; Chimon, Ghislain N; Seah, Alvin B H; Chang, Hui Meng; Wong, Meng Cheong; Ng, Yee Kong; Rumpel, Helmut; Halliwell, Barry; Chen, Christopher P L H

    2006-02-01

    Cysteine is known to cause neuronal cell death and has been reported to be elevated in brain ischemia, but it has not been studied in clinical stroke. In this study, we correlated plasma levels of cyst(e)ine with long-term clinical outcome at 3 months in acute stroke. Patients were classified into 3 groups at 3 months as follows: good outcome (Rankin 0-1, n = 11), poor outcome (Rankin 2-5, n = 20), and dead (n = 5). Their plasma cyst(e)ine levels within 24 hours of stroke onset were 61 +/- 12, 67 +/- 9, and 82 +/- 14 micromol/L (standard deviation), respectively. The correlation between early plasma cyst(e)ine levels and long-term clinical outcome assessed at 3 months is significant with p ine was also significantly elevated in patients who had early stroke deterioration (p ine in patients with stroke may reflect increased production of H2S in the brain and thus predispose to poor outcome in clinical stroke. Inhibition of H2S formation may therefore be a novel approach in acute stroke therapy.

  17. New recommendations for dose equivalent

    International Nuclear Information System (INIS)

    Bengtsson, G.

    1985-01-01

    In its report 39, the International Commission on Radiation Units and Measurements (ICRU), has defined four new quantities for the determination of dose equivalents from external sources: the ambient dose equivalent, the directional dose equivalent, the individual dose equivalent, penetrating and the individual dose equivalent, superficial. The rationale behind these concepts and their practical application are discussed. Reference is made to numerical values of these quantities which will be the subject of a coming publication from the International Commission on Radiological Protection, ICRP. (Author)

  18. System equivalent model mixing

    Science.gov (United States)

    Klaassen, Steven W. B.; van der Seijs, Maarten V.; de Klerk, Dennis

    2018-05-01

    This paper introduces SEMM: a method based on Frequency Based Substructuring (FBS) techniques that enables the construction of hybrid dynamic models. With System Equivalent Model Mixing (SEMM) frequency based models, either of numerical or experimental nature, can be mixed to form a hybrid model. This model follows the dynamic behaviour of a predefined weighted master model. A large variety of applications can be thought of, such as the DoF-space expansion of relatively small experimental models using numerical models, or the blending of different models in the frequency spectrum. SEMM is outlined, both mathematically and conceptually, based on a notation commonly used in FBS. A critical physical interpretation of the theory is provided next, along with a comparison to similar techniques; namely DoF expansion techniques. SEMM's concept is further illustrated by means of a numerical example. It will become apparent that the basic method of SEMM has some shortcomings which warrant a few extensions to the method. One of the main applications is tested in a practical case, performed on a validated benchmark structure; it will emphasize the practicality of the method.

  19. Učinkovitost terapevtskega ultrazvoka pri zmanjševanju bolečine pri artrozi kolena

    OpenAIRE

    Blas, Marjeta

    2018-01-01

    Uvod: Artroza je degenerativni proces, ki lahko privede do deformacije kolenskega sklepa ter predvsem pri starejših povzroči težave pri vsakodnevnih opravilih in zmanjša kakovost njihovega življenja. Glavni simptom je bolečina. Pomembno vlogo pri zdravljenju ima fizioterapija. Inštrumentalna fizioterapija, kot je ultrazvok, se pogosto uporablja za zmanjševanje bolečine ali kot predpriprava na vadbo. Namen: Namen diplomskega dela je na osnovi pregleda objavljene strokovne in znanstvene literat...

  20. Unprecedented twofold intramolecular hydroamination in diam(m)ine-dicarboxylatodichloridoplatinum(IV) complexes - ethane-1,2-diamine vs. ammine ligands.

    Science.gov (United States)

    Reithofer, Michael R; Galanski, Markus; Arion, Vladimir B; Keppler, Bernhard K

    2008-03-07

    Reaction of (OC-6-13)-bis(2Z-3-carboxyacrylato)dichlorido(ethane-1,2-diamine)platinum(IV) and (OC-6-13)-diamminebis(2Z-3-carboxyacrylato)dichloridoplatinum(IV) with propylamine in the presence of 1,1'-carbonyl diimidazole afforded not the expected amides; instead, beside amide formation, a twofold intramolecular attack of the am(m)ine ligand at the C[double bond, length as m-dash]C bonds was observed involving either both (ethane-1,2-diamine) or only one (ammine) coordinated nitrogen atom(s).

  1. The New Migration Statistics: A Good Choice made by the INE (Spanish Institute for National Statistics [ENG

    Directory of Open Access Journals (Sweden)

    Carmen Ródenas

    2013-01-01

    Full Text Available The Spanish Institute for National Statistics (INE has decided to create new Migration Statistics (Estadística de Migraciones based upon Residential Variation Statistics (Estadística de Variaciones Residenciales. This article presents arguments to support this decision, in view of the continued lack of consistency found among the sources of the Spanish statistics system for measuring population mobility. Specifically, an insight is provided into the problems of underestimation and internal inconsistency in the Spanish Labour Force Survey when measuring immigration rates, based upon discrepancies identified in the three international immigration flow series produced by this survey.

  2. The equivalence principle

    International Nuclear Information System (INIS)

    Smorodinskij, Ya.A.

    1980-01-01

    The prerelativistic history of the equivalence principle (EP) is presented briefly. Its role in history of the general relativity theory (G.R.T.) discovery is elucidated. A modern idea states that the ratio of inert and gravitational masses does not differ from 1 at least up to the 12 sign after comma. Attention is paid to the difference of the gravitational field from electromagnetic one. The difference is as follows, the energy of the gravitational field distributed in space is the source of the field. These fields always interact at superposition. Electromagnetic fields from different sources are put together. On the basis of EP it is established the Sun field interact with the Earth gravitational energy in the same way as with any other one. The latter proves the existence of gravitation of the very gravitational field to a heavy body. A problem on gyroscope movement in the Earth gravitational field is presented as a paradox. The calculation has shown that gyroscope at satellite makes a positive precession, and its axis turns in an angle equal to α during a turn of the satellite round the Earth, but because of the space curvature - into the angle two times larger than α. A resulting turn is equal to 3α. It is shown on the EP basis that the polarization plane in any coordinate system does not turn when the ray of light passes in the gravitational field. Together with the historical value of EP noted is the necessity to take into account the requirements claimed by the EP at description of the physical world

  3. What level of plasma homocyst(e)ine should be treated? Effects of vitamin therapy on progression of carotid atherosclerosis in patients with homocyst(e)ine levels above and below 14 micromol/L.

    Science.gov (United States)

    Hackam, D G; Peterson, J C; Spence, J D

    2000-01-01

    High levels of plasma homocyst(e)ine (H[e]) are associated with increased vascular risk. Treatment is being contemplated, but the level at which patients should be treated is not known. We compared the response of carotid plaque to vitamin therapy in patients with H(e) above and below 14 micromol/L, a level commonly regarded as high enough to warrant treatment. Two-dimensional B-mode ultrasound measurement of carotid plaque was used to assess the response to vitamin therapy with folic acid 2.5 mg, pyridoxine 25 mg, and cyanocobalamin 250 microg daily, in 101 patients with vascular disease (51 with initial plasma levels above, and 50 below 14 micromol/L). Among patients with plasma H(e) >14 micromol/L, the rate of progression of plaque area was 0.21 +/- 0.41 cm2/year before vitamin therapy, and -0.049 +/- 0.24 cm2/year after vitamin therapy (P2 = .0001; paired t test). Among patients with levels ine and atherosclerosis and, taken with epidemiologic evidence, suggest that in patients with vascular disease, the level to treat may be <9 micromol/L.

  4. Dégradation de la caféine par Aspergillus sp. et Penicillium sp. : étude physiologique et biochimique

    OpenAIRE

    Denis, Sylvain

    1996-01-01

    Ce travail a été axé sur la compréhension des mécanismes physiologiques et biochimiques de la dégradation de la caféine (ou 1,3,7-triméthylxanthine) par deux champignons filamenteux cultivés en milieu liquide synthétique à base de caféine et de saccharose. Les deux souches retenues pour cette étude appartiennent aux genres #Aspergillus$ et #Penicillium$. Deux méthodes chromatographiques (CLHP et CCM) ont été optimisées pour la détermination qualitative et quantitative de la caféine et de tout...

  5. Etude et fonctionnalisation de protéines végétales en vue de leur application en microencapsulation

    OpenAIRE

    Nesterenko, Alla

    2012-01-01

    Les protéines extraites des végétaux sont des matériaux relativement peu coûteux, non toxiques, biocompatibles et biodégradables. Elles représentent une bonne alternative aux protéines d’origine animale et aux polymères dérivés du pétrole. Dans le cadre de cette étude, les protéines extraites de graines de soja et de tournesol ont été utilisées en tant que matériaux enrobants pour la microencapsulation de la matière active hydrophobe (α-tocophérol) ou hydrophile (acide ascorbique) par le proc...

  6. A pilot study of homocyst(e)ine levels in essential hypertension: relationship to von Willebrand factor, an index of endothelial damage.

    Science.gov (United States)

    Lip, G Y; Edmunds, E; Martin, S C; Jones, A F; Blann, A D; Beevers, D G

    2001-07-01

    An interaction between homocyst(e)ine and the endothelium in hypertensive patients may promote thrombogenesis and atherogenesis, leading to adverse cardiovascular events. We hypothesized that homocyst(e)ine levels are abnormal in patients with essential hypertension, and that this may be related to an adverse effect on the vascular endothelium. Accordingly, we compared plasma levels of homocyst(e)ine and von Willebrand factor (marking endothelial damage) in 83 patients (43 men; mean age 54 +/- standard deviation 15.9 years) with essential hypertension (> 160/90 mm Hg), with levels in 25 healthy normotensive controls (13 men; mean age 56+/-11.8 years). Baseline levels of the markers and other clinical indices were then related to adverse cardiovascular events at follow-up. Plasma homocyst(e)ine (P = .0001) and von Willebrand factor (P = .031) levels were significantly higher in hypertensives compared to controls. After a mean follow-up of 76 patients for 45 months (range, 1 to 66 months), 17 subjects experienced an end point of either cardiovascular death (n = 10) or adverse cardiovascular event (n = 7). Comparing these 17 with the 59 free of an end point, the former were older (P = .0002) and had a longer duration of known hypertension (P = .018). There was a nonsignificant trend toward higher median plasma homocyst(e)ine levels in the patients sustaining a vascular end point (P = .07). In this pilot study, we suggest that essential hypertension may be associated with increased plasma homocyst(e)ine levels, but that this amino acid is unrelated to endothelial damage (von Willebrand factor), clinical indices, or prognosis.

  7. Homocyst(e)ine and cardiovascular disease: a systematic review of the evidence with special emphasis on case-control studies and nested case-control studies.

    Science.gov (United States)

    Ford, Earl S; Smith, S Jay; Stroup, Donna F; Steinberg, Karen K; Mueller, Patricia W; Thacker, Stephen B

    2002-02-01

    Elevated concentrations of homocyst(e)ine are thought to increase the risk of vascular diseases including coronary heart disease and cerebrovascular disease. We searched MEDLINE (1966-1999), EMBASE (1974-1999), SciSearch (1974- 1999), and Dissertation Abstracts (1999) for articles and theses about homocyst(e)ine concentration and coronary heart disease and cerebrovascular disease. We included 57 publications (3 cohort studies, 12 nested case-control studies, 42 case-control studies) that reported results on 5518 people with coronary heart disease (11,068 control subjects) and 1817 people with cerebrovascular disease (4787 control subjects) in our analysis. For coronary heart disease, the summary odds ratios (OR) for a 5-micromol/l increase in homocyst(e)ine concentration were 1.06 (95% CI : 0.99-1.13) for 2 publications of cohort studies, 1.23 (95% CI : 1.07-1.41) for 10 publications of nested case-control studies, and 1.70 (95% CI : 1.50-1.93) for 26 publications of case-control studies. For cerebrovascular disease, the summary OR for a 5-micromol/l increase in homocyst(e)ine concentration were 1.10 (95% CI : 0.94-1.28) for 2 publications of cohort studies, 1.58 (95% CI : 1.35-1.85) for 5 publications of nested case-control studies, and 2.16 (95% CI : 1.65-2.82) for 17 publications of case-control studies. Prospective studies offer weaker support than case-control studies for an association between homocyst(e)ine concentration and cardiovascular disease. Although other lines of evidence support a role for homocyst(e)ine in the pathogenesis of cardiovascular disease, more information from prospective epidemiological studies or clinical trials is needed to clarify this role.

  8. Logically automorphically equivalent knowledge bases

    OpenAIRE

    Aladova, Elena; Plotkin, Tatjana

    2017-01-01

    Knowledge bases theory provide an important example of the field where applications of universal algebra and algebraic logic look very natural, and their interaction with practical problems arising in computer science might be very productive. In this paper we study the equivalence problem for knowledge bases. Our interest is to find out how the informational equivalence is related to the logical description of knowledge. Studying various equivalences of knowledge bases allows us to compare d...

  9. Extracellular concentration of homocysteine in human cell lines is influenced by specific inhibitors of cyst(e)ine transport.

    Science.gov (United States)

    Hultberg, Björn

    2004-04-01

    Despite the growing evidence that plasma homocysteine is a cardiovascular risk factor, the mechanism behind the vascular injuries is still unknown. Studies of the cellular uptake systems for homocysteine are scarce, but membrane transporters of cyst(e)ine seem to be involved. In the present study the cellular uptake of extracellular homocysteine in HeLa and hepatoma cell lines is investigated by using several different transport inhibitors for cellular uptake of cyst(e)ine. It is shown that systems A and Xc- are the main transport systems for homocysteine uptake in HeLa cells. It is also confirmed that the magnitude of homocysteine uptake in hepatoma cells is lower than in HeLa cells. However, in the presence of high amounts of extracellular homocysteine both cell types exhibited a high elimination of homocysteine, which was inhibited by the presence of inhibitors of systems A or Xc-. It is possible that there is normally a high turnover of homocysteine in cell cultures, which is not detected by occasional determinations of homocysteine concentrations. The complex pattern of homocysteine production, release, uptake and distribution between different cells in the body is important to examine further in order to possibly be able to modulate the elimination of homocysteine from circulation and thereby lower the risk of cardiovascular disease.

  10. Homocyst(e)ine-lowering therapy does not affect plasma asymmetrical dimethylarginine concentrations in patients with peripheral artery disease.

    Science.gov (United States)

    Ziegler, Sophie; Mittermayer, Friedrich; Plank, Christina; Minar, Erich; Wolzt, Michael; Schernthaner, Gerit-Holger

    2005-04-01

    Elevated plasma asymmetrical dimethylarginine (ADMA) is suggested to contribute to hyperhomocyst(e)ine-related vascular dysfunction in patients with peripheral artery disease (PAD). The present trial investigated whether homocyst(e)ine (Hcy)-lowering therapy with vitamin-B (vit-B) and folic acid affects plasma concentrations of ADMA in patients with PAD and hyperhomocyst(e)inemia. Forty-nine subjects (15 women, 34 men) with PAD and fasting plasma total Hcy concentrations greater than 15 micromol/liter were randomized to receive either oral vit-B and folic acid therapy (n = 27) or placebo (n = 22) for 6 wk. Fasting venous blood samples were monitored for plasma total Hcy, vit-B12 and folate, ADMA, symmetric dimethylarginine, L-arginine, and high-sensitivity C-reactive protein. After 6 wk, plasma Hcy concentrations were decreased, and concentrations of vit-B12 and folate were elevated in patients with vitamin supplementation (all P < 0.05 vs. baseline) and unchanged in the placebo group. Dimethylarginine plasma concentrations were not affected by treatment. High-sensitivity C-reactive protein correlated with ADMA plasma concentrations (r = 0.29; P < 0.01). The lack of vit-B and folic acid therapy on plasma concentrations of ADMA renders a role of extracellular methylarginines unlikely to be involved in the pathophysiology of hyperhomocyst(e)inemia and its complications.

  11. Aleurone flour increases red-cell folate and lowers plasma homocyst(e)ine substantially in man.

    Science.gov (United States)

    Fenech, Michael; Noakes, Manny; Clifton, Peter; Topping, David

    2005-03-01

    Aleurone flour (ALF) is a rich source of natural folate (>500 microg/100 g wet weight). Our objective was to establish whether intake of ALF in man can significantly improve folate status and reduce plasma homocyst(e)ine. We performed a randomised, controlled intervention, of 16 weeks duration, in free-living healthy individuals (mean age 46-52 years). Participants were assigned to one of three groups: ALF, 175 g bread made with ALF and placebo tablet each day; PCS, 175 g bread made with pericarp seed coat (PCS) flour and placebo tablet each day (low-folate control); or FA, 175 g bread made with PCS flour and tablet containing 640 microg folic acid each day (high-folate control). The daily folate intake contributed by the bread and tablet was 233 microg in the PCS group, 615 microg in the ALF group and 819 microg in the FA group. The number of participants completing all phases of the PCS, ALF and FA interventions was twenty-five, twenty-five and eighteen, respectively. Plasma and red-cell folate increased significantly (Pine decreased significantly (Pine in the ALF group decreased from 9.1 (8.2, 10.0) micromol/l at baseline to 6.8 (6.2, 7.5) micromol/l after 16 weeks. In conclusion, moderate dietary intake of ALF can increase red-cell folate and decrease plasma homocyst(e)ine substantially.

  12. Neonatal epileptic encephalopathy caused by mutations in the PNPO gene encoding pyridox(am)ine 5'-phosphate oxidase.

    Science.gov (United States)

    Mills, Philippa B; Surtees, Robert A H; Champion, Michael P; Beesley, Clare E; Dalton, Neil; Scambler, Peter J; Heales, Simon J R; Briddon, Anthony; Scheimberg, Irene; Hoffmann, Georg F; Zschocke, Johannes; Clayton, Peter T

    2005-04-15

    In the mouse, neurotransmitter metabolism can be regulated by modulation of the synthesis of pyridoxal 5'-phosphate and failure to maintain pyridoxal phosphate (PLP) levels results in epilepsy. This study of five patients with neonatal epileptic encephalopathy suggests that the same is true in man. Cerebrospinal fluid and urine analyses indicated reduced activity of aromatic L-amino acid decarboxylase and other PLP-dependent enzymes. Seizures ceased with the administration of PLP, having been resistant to treatment with pyridoxine, suggesting a defect of pyridox(am)ine 5'-phosphate oxidase (PNPO). Sequencing of the PNPO gene identified homozygous missense, splice site and stop codon mutations. Expression studies in Chinese hamster ovary cells showed that the splice site (IVS3-1g>a) and stop codon (X262Q) mutations were null activity mutations and that the missense mutation (R229W) markedly reduced pyridox(am)ine phosphate oxidase activity. Maintenance of optimal PLP levels in the brain may be important in many neurological disorders in which neurotransmitter metabolism is disturbed (either as a primary or as a secondary phenomenon).

  13. Testing statistical hypotheses of equivalence

    CERN Document Server

    Wellek, Stefan

    2010-01-01

    Equivalence testing has grown significantly in importance over the last two decades, especially as its relevance to a variety of applications has become understood. Yet published work on the general methodology remains scattered in specialists' journals, and for the most part, it focuses on the relatively narrow topic of bioequivalence assessment.With a far broader perspective, Testing Statistical Hypotheses of Equivalence provides the first comprehensive treatment of statistical equivalence testing. The author addresses a spectrum of specific, two-sided equivalence testing problems, from the

  14. SAPONIFICATION EQUIVALENT OF DASAMULA TAILA

    OpenAIRE

    Saxena, R. B.

    1994-01-01

    Saponification equivalent values of Dasamula taila are very useful for the technical and analytical work. It gives the mean molecular weight of the glycerides and acids present in Dasamula Taila. Saponification equivalent values of Dasamula taila are reported in different packings.

  15. Saponification equivalent of dasamula taila.

    Science.gov (United States)

    Saxena, R B

    1994-07-01

    Saponification equivalent values of Dasamula taila are very useful for the technical and analytical work. It gives the mean molecular weight of the glycerides and acids present in Dasamula Taila. Saponification equivalent values of Dasamula taila are reported in different packings.

  16. A study on lead equivalent

    International Nuclear Information System (INIS)

    Lin Guanxin

    1991-01-01

    A study on the rules in which the lead equivalent of lead glass changes with the energy of X rays or γ ray is described. The reason of this change is discussed and a new testing method of lead equivalent is suggested

  17. Evaluation of 1cm dose equivalent rate using a NaI(Tl) scintilation spectrometer

    International Nuclear Information System (INIS)

    Matsuda, Hideharu

    1990-01-01

    A method for evaluating 1 cm dose equivalent rates from a pulse height distribution obtained by a 76.2mmφ spherical NaI(Tl) scintillation spectrometer was described. Weak leakage radiation from nuclear facilities were also measured and dose equivalent conversion factor and effective energy of leakage radiation were evaluated from 1 cm dose equivalent rate and exposure rate. (author)

  18. 10 CFR 20.1208 - Dose equivalent to an embryo/fetus.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Dose equivalent to an embryo/fetus. 20.1208 Section 20... Limits § 20.1208 Dose equivalent to an embryo/fetus. (a) The licensee shall ensure that the dose equivalent to the embryo/fetus during the entire pregnancy, due to the occupational exposure of a declared...

  19. Determination of dose equivalent with tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Dietze, G.; Schuhmacher, H.; Menzel, H.G.

    1989-01-01

    Low pressure tissue-equivalent proportional counters (TEPC) are instruments based on the cavity chamber principle and provide spectral information on the energy loss of single charged particles crossing the cavity. Hence such detectors measure absorbed dose or kerma and are able to provide estimates on radiation quality. During recent years TEPC based instruments have been developed for radiation protection applications in photon and neutron fields. This was mainly based on the expectation that the energy dependence of their dose equivalent response is smaller than that of other instruments in use. Recently, such instruments have been investigated by intercomparison measurements in various neutron and photon fields. Although their principles of measurements are more closely related to the definition of dose equivalent quantities than those of other existing dosemeters, there are distinct differences and limitations with respect to the irradiation geometry and the determination of the quality factor. The application of such instruments for measuring ambient dose equivalent is discussed. (author)

  20. Geochemistry of rare earths and oxygen isotopes in granitic rocks from Monte das Gameleiras and Dona Ines, Rio Grande do Norte-Paraiba border, Brazil

    International Nuclear Information System (INIS)

    Sial, A.N.

    1984-01-01

    The study of oxygen isotopes and rare earth elements in granitic plutons of Monte das Gameleiras and Dona Ines, Rio Grande do Norte-Paraiba border, in Brazil, to define the nature of source rock of progenitor magmas, is presented. (M.C.K.) [pt

  1. Influence of folic acid, pyridoxal phosphate and cobalamin on plasma homocyst(e)ine levels and the susceptibility of low-density lipoprotein to ex-vivo oxidation.

    Science.gov (United States)

    Weiss, N; Feussner, A; Hailer, S; Spengel, F A; Keller, C; Wolfram, G

    1999-10-15

    Mild hyperhomocyst(e)inaemia is a risk factor for atherosclerotic vascular disease. In-vitro studies have shown that autooxidation of homocyst(e)ine is accompanied by the generation of oxygen radicals. This may lead to oxidative modification of low-density lipoproteins (LDL) and promote atherosclerotic vascular lesions. In male patients with peripheral arterial occlusive disease we determined fasting and post methionine load homocyst(e)ine levels by high performance liquid chromatography and the susceptibility of their LDL particles to ex-vivo oxidation by continously measuring the conjugated diene production induced by incubation with copper ions. Oxidation resistance (expressed as lag time), maximal oxidation rate, and extent of oxidation (expressed of total diene production) of LDL from patients with normal or mildly elevated homocyst(e)ine levels did not differ significantly. Folic acid, pyridoxal phosphate and cobalamin supplementation significantly decreased plasma homocyst(e)ine levels in hyperhomocyst(e)inaemic patients. This went along with a significant decrease in the extent of LDL oxidation and additionally increased HDL-cholesterol levels. The clinical relevance of these findings for the long-term course of atherosclerotic vascular disorders has to be determined by intervention studies.

  2. Pyridox(am)ine-5-Phosphate Oxidase Deficiency Treatable Cause of Neonatal Epileptic Encephalopathy With Burst Suppression: Case Report and Review of the Literature.

    Science.gov (United States)

    Guerin, Andrea; Aziz, Aly S; Mutch, Carly; Lewis, Jillian; Go, Cristina Y; Mercimek-Mahmutoglu, Saadet

    2015-08-01

    Pyridox(am)ine-5-phosphate oxidase deficiency is an autosomal recessive disorder of pyridoxine metabolism. Intractable neonatal epileptic encephalopathy is the classical presentation. Pyridoxal-5-phosphate or pyridoxine supplementation improves symptoms. We report a patient with myoclonic and tonic seizures at the age of 1 hour. Pyridoxal-5-phosphate was started on the first day of life and seizures stopped at the age of 3 days, but encephalopathy persisted for 4 weeks. She had normal neurodevelopmental outcome at the age of 12 months on pyridoxal-5-phosphate monotherapy. She had novel homozygous pathogenic frameshift mutation (c.448_451del;p.Pro150Argfs*27) in the PNPO gene. Long-lasting encephalopathy despite well-controlled clinical seizures does neither confirm nor exclude pyridox(am)ine-5-phosphate oxidase deficiency. Normal neurodevelopmental outcome of our patient emphasizes the importance of pyridoxal-5-phosphate treatment. Pyridox(am)ine-5-phosphate oxidase deficiency should be included in the differential diagnosis of Ohtahara syndrome and neonatal myoclonic encephalopathy as a treatable underlying cause. In addition, we reviewed the literature for pyridox(am)ine-5-phosphate oxidase deficiency and summarized herein all confirmed cases. © The Author(s) 2014.

  3. Reduction of plasma homocyst(e)ine levels by breakfast cereal fortified with folic acid in patients with coronary heart disease.

    Science.gov (United States)

    Malinow, M R; Duell, P B; Hess, D L; Anderson, P H; Kruger, W D; Phillipson, B E; Gluckman, R A; Block, P C; Upson, B M

    1998-04-09

    The Food and Drug Administration (FDA) has recommended that cereal-grain products be fortified with folic acid to prevent congenital neural-tube defects. Since folic acid supplementation reduces levels of plasma homocyst(e)ine, or plasma total homocysteine, which are frequently elevated in arterial occlusive disease, we hypothesized that folic acid fortification might reduce plasma homocyst(e)ine levels. To test this hypothesis, we assessed the effects of breakfast cereals fortified with three levels of folic acid, and also containing the recommended dietary allowances of vitamins B6 and B12, in a randomized, double-blind, placebo-controlled, crossover trial in 75 men and women with coronary artery disease. Plasma folic acid increased and plasma homocyst(e)ine decreased proportionately with the folic acid content of the breakfast cereal. Cereal providing 127 microg of folic acid daily, approximating the increased daily intake that may result from the FDA's enrichment policy, increased plasma folic acid by 31 percent (P=0.045) but decreased plasma homocyst(e)ine by only 3.7 percent (P= 0.24). However, cereals providing 499 and 665 microg of folic acid daily increased plasma folic acid by 64.8 percent (Pine by 11.0 percent (Pine levels. Further clinical trials are required to determine whether folic acid fortification may prevent vascular disease. Until then, our results suggest that folic acid fortification at levels higher than that recommended by the FDA may be warranted.

  4. What is correct: equivalent dose or dose equivalent

    International Nuclear Information System (INIS)

    Franic, Z.

    1994-01-01

    In Croatian language some physical quantities in radiation protection dosimetry have not precise names. Consequently, in practice either terms in English or mathematical formulas are used. The situation is even worse since the Croatian language only a limited number of textbooks, reference books and other papers are available. This paper compares the concept of ''dose equivalent'' as outlined in International Commission on Radiological Protection (ICRP) recommendations No. 26 and newest, conceptually different concept of ''equivalent dose'' which is introduced in ICRP 60. It was found out that Croatian terminology is both not uniform and unprecise. For the term ''dose equivalent'' was, under influence of Russian and Serbian languages, often used as term ''equivalent dose'' even from the point of view of ICRP 26 recommendations, which was not justified. Unfortunately, even now, in Croatia the legal unit still ''dose equivalent'' defined as in ICRP 26, but the term used for it is ''equivalent dose''. Therefore, in Croatian legislation a modified set of quantities introduced in ICRP 60, should be incorporated as soon as possible

  5. Committed dose equivalent in the practice of radiological protection

    International Nuclear Information System (INIS)

    Nenot, J.C.; Piechowski, J.

    1985-01-01

    In the case of internal exposure, the dose is not received at the moment of exposure, as happens with external exposure, since the incorporated radionuclide irradiates the various organs and tissues during the time it is present in the body. By definition, the committed dose equivalent corresponds to the received dose integrated over 50 years from the date of intake. In order to calculate it, one has to know the intake activity and the value of the committed dose equivalent per unit of intake activity. The uncertainties of the first parameter are such that the committed dose equivalent can only be regarded as an order of magnitude and not as a very accurate quantity. The use of it is justified, however, for, like the dose equivalent for external exposure, it expresses the risk of stochastic effects for the individual concerned since these effects, should they appear, would do so only after a latent period which is generally longer than the dose integration time. Moreover, the use of the committed dose equivalent offers certain advantages for dosimetric management, especially when it is simplified. A practical problem which may arise is that the annual dose limit is apparently exceeded by virtue of the fact that one is taking account, in the first year, of doses which will actually be received only in the following years. These problems are rare enough in practice to be dealt with individually in each case. (author)

  6. Consommation de caféine pendant la grossesse : retentissements maternels, foetaux, néonatals et infantiles

    OpenAIRE

    ALTIERI, Marie

    2015-01-01

    Introduction : La caféine, essentiellement présente dans le café, le thé, les boissons énergisantes, le cola, le cacao et certains médicaments, est la substance psychoactive la plus consommée pendant la grossesse. Elle traverse la barrière placentaire et présente une élimination ralentie chez la femme enceinte, le foetus et le nourrisson. Les études animales ont mis en évidence sa tératogénicité et sa toxicité pour la gestation et la santé des progénitures. Qu’en est-il du déroulement de la g...

  7. Research and education on innovative nuclear engineering in 21. century COE program in Japan (COE-INES)

    International Nuclear Information System (INIS)

    Hiroshi Sekimoto

    2004-01-01

    -In the year 2002 and 2003 the Japanese Ministry of Education, Culture, Sports, Science and Technology (MEXT) started the 'Priority Assistance for the Formation of Worldwide Renowned Centers of Research - The 21. Century Center of Excellence (COE) Program'. A program proposed by Tokyo Institute of Technology (TITech) 'Innovative Nuclear Energy Systems for Sustainable Development of the World (COE-INES)' was selected as the only one program in nuclear engineering. Here the innovative nuclear energy systems include innovative nuclear reactors and innovative separation and transmutation technologies. This program is planned to continue for 5 years, and the monetary support for the first year (2003-4) is already fixed to be 196 M yens. International collaboration will be promoted for research and education on innovative nuclear energy systems. Several international meetings and intensive personnel exchanges will be performed. (author)

  8. Book of presentations. Tokyo Tech COE-INES. Indonesia international symposium 2005. 'Prospect of nuclear energy in Indonesia'

    International Nuclear Information System (INIS)

    2005-03-01

    The symposium of the title was organized by the 21st Century COE Program, Innovative Nuclear Energy Systems for Sustainable Development of the World, the Tokyo Institute of Technology (Tokyo Tech COE-INES), the Bandung Institute of Technology (ITB), and the National Nuclear Energy Agency of Indonesia (BATAN). The symposium included presentations of 21 from Japan 24 from Indonesia and discussions on innovative nuclear energy systems and on a number of topics related to nuclear energy, including long-term policies and regulation for its development. Students from Japan and Indonesia played an important role in the symposium, presenting excellent work and discussion on their research topics as well as participating in very fruitful panel discussions on 'Education in Nuclear Field' and 'Attractiveness of Jobs in the Nuclear Field'. (J.P.N.)

  9. Use of reduced doses of eCG applied by different routes in the TAI program in Santa Ines sheep

    Directory of Open Access Journals (Sweden)

    Karla Dias Antunes-Melo

    2015-06-01

    Full Text Available The aims of this study were to improve the cost-benefit ratio of the application of artificial insemination in fixed time (TAI by the transcervical route in sheep, to test the dosage reduction and the use of the vulvar submucosa (VSM route as an alternative for the application of equine chorionic gonadotropin (eCG on the efficiency of the synchronization protocol and fertility to artificial insemination (AI and to measure the level of cortisol in ewes as a result the application of this biotechnique. Blood samples were collected before AI, immediately after AI and seven days after AI. Six groups of twenty animals were used, and each group received doses of 200, 300 and 400 IU of eCG by the intramuscular route (IM and VSM. Estrus was detected, and 48 hours later, the inseminations were performed by the transcervical route. Among the 120 treated ewes, 87.5% came in estrus. The percentage of the intrauterine deposition of semen was 88.3%. The pregnancy rate ranged from 20 to 70% between treatments, with an average of 46.66%. The VSM route was viable for the application of eCG in doses of 300 and 400 IU. The reduction in the eCG dose to 200 IU by the IM route reduces costs while maintaining the efficiency of estrus synchronization protocols and TAI with frozen semen in Santa Ines ewes. The average levels of cortisol were significant, at 1.15, 2.86 and 0.52 ?g/dL according to the three collections, being higher after the animal was off the easel at the end of AI. The procedures for performing the transcervical AI technique indicate that stress in the animals produces satisfactory fertility results and a low cost in multiparous ewes of the Santa Ines breed.

  10. Symmetries of dynamically equivalent theories

    Energy Technology Data Exchange (ETDEWEB)

    Gitman, D.M.; Tyutin, I.V. [Sao Paulo Univ., SP (Brazil). Inst. de Fisica; Lebedev Physics Institute, Moscow (Russian Federation)

    2006-03-15

    A natural and very important development of constrained system theory is a detail study of the relation between the constraint structure in the Hamiltonian formulation with specific features of the theory in the Lagrangian formulation, especially the relation between the constraint structure with the symmetries of the Lagrangian action. An important preliminary step in this direction is a strict demonstration, and this is the aim of the present article, that the symmetry structures of the Hamiltonian action and of the Lagrangian action are the same. This proved, it is sufficient to consider the symmetry structure of the Hamiltonian action. The latter problem is, in some sense, simpler because the Hamiltonian action is a first-order action. At the same time, the study of the symmetry of the Hamiltonian action naturally involves Hamiltonian constraints as basic objects. One can see that the Lagrangian and Hamiltonian actions are dynamically equivalent. This is why, in the present article, we consider from the very beginning a more general problem: how the symmetry structures of dynamically equivalent actions are related. First, we present some necessary notions and relations concerning infinitesimal symmetries in general, as well as a strict definition of dynamically equivalent actions. Finally, we demonstrate that there exists an isomorphism between classes of equivalent symmetries of dynamically equivalent actions. (author)

  11. Matching of equivalent field regions

    DEFF Research Database (Denmark)

    Appel-Hansen, Jørgen; Rengarajan, S.B.

    2005-01-01

    In aperture problems, integral equations for equivalent currents are often found by enforcing matching of equivalent fields. The enforcement is made in the aperture surface region adjoining the two volumes on each side of the aperture. In the case of an aperture in a planar perfectly conducting...... screen, having the same homogeneous medium on both sides and an impressed current on one aide, an alternative procedure is relevant. We make use of the fact that in the aperture the tangential component of the magnetic field due to the induced currents in the screen is zero. The use of such a procedure...... shows that equivalent currents can be found by a consideration of only one of the two volumes into which the aperture plane divides the space. Furthermore, from a consideration of an automatic matching at the aperture, additional information about tangential as well as normal field components...

  12. Teleparallel equivalent of Lovelock gravity

    Science.gov (United States)

    González, P. A.; Vásquez, Yerko

    2015-12-01

    There is a growing interest in modified gravity theories based on torsion, as these theories exhibit interesting cosmological implications. In this work inspired by the teleparallel formulation of general relativity, we present its extension to Lovelock gravity known as the most natural extension of general relativity in higher-dimensional space-times. First, we review the teleparallel equivalent of general relativity and Gauss-Bonnet gravity, and then we construct the teleparallel equivalent of Lovelock gravity. In order to achieve this goal, we use the vielbein and the connection without imposing the Weitzenböck connection. Then, we extract the teleparallel formulation of the theory by setting the curvature to null.

  13. Attainment of radiation equivalency principle

    International Nuclear Information System (INIS)

    Shmelev, A.N.; Apseh, V.A.

    2004-01-01

    Problems connected with the prospects for long-term development of the nuclear energetics are discussed. Basic principles of the future large-scale nuclear energetics are listed, primary attention is the safety of radioactive waste management of nuclear energetics. The radiation equivalence principle means close of fuel cycle and management of nuclear materials transportation with low losses on spent fuel and waste processing. Two aspects are considered: radiation equivalence in global and local aspects. The necessity of looking for other strategies of fuel cycle management in full-scale nuclear energy on radioactive waste management is supported [ru

  14. Technical background for shallow (skin) dose equivalent evaluations

    International Nuclear Information System (INIS)

    Ashley, J.C.; Turner, J.E.; Crawford, O.H.; Hamm, R.N.; Reaves, K.L.; McMahan, K.L.

    1991-01-01

    Department of Energy Order 5480.11 describes procedures for radiation protection for occupational workers. The revisions dealing with non-uniform exposure to the skin are the subject of this report. We describe measurements and analysis required to assess shallow (skin) dose equivalent from skin contamination. 6 refs., 4 tabs

  15. Anksioznost učencev 6. razreda osnovne šole pri pouku angleščine kot tujega jezika v povezavi z njihovo učno uspešnostjo

    OpenAIRE

    Praček, Anja

    2017-01-01

    Magistrsko delo obravnava anksioznost šestošolcev pri pouku angleščine kot tujega jezika v povezavi z njihovo učno uspešnostjo pri pouku angleščine. Pouk angleščine se v marsičem razlikuje od drugih šolskih predmetov in prav ta posebna učna situacija lahko pri učencih izzove anksioznost. Magistrsko delo je sestavljeno iz teoretičnega in empiričnega dela. V teoretičnem delu je s pomočjo literature na kratko predstavljena trenutna situacija poučevanja in učenja angleščine v slovenskih javnih...

  16. Comments on field equivalence principles

    DEFF Research Database (Denmark)

    Appel-Hansen, Jørgen

    1987-01-01

    It is pointed Out that often-used arguments based on a short-circuit concept in presentations of field equivalence principles are not correct. An alternative presentation based on the uniqueness theorem is given. It does not contradict the results obtained by using the short-circuit concept...

  17. Association between total homocyst(e)ine and the likelihood for a history of acute myocardial infarction by race and ethnicity: Results from the Third National Health and Nutrition Examination Survey.

    Science.gov (United States)

    Giles, W H; Croft, J B; Greenlund, K J; Ford, E S; Kittner, S J

    2000-03-01

    Few studies examining the association between total homocyst(e)ine and coronary heart disease have included blacks or Hispanics. Data from the third National Health and Nutrition Examination Survey (3173 patients), a nationally representative survey of US adults, were used to examine the relation between total homocyst(e)ine and an electrocardiogram or a physician's diagnosis of acute myocardial infarction (259 patients) among whites, blacks, and Mexican Americans >/=40 years old. Vitamin B(12) and serum folate concentrations were significantly lower among persons with a total homocyst(e)ine concentration >/=15 micromol/L than among those with a total homocyst(e)ine concentration ine concentration >/=15 micromol/L were also older and more likely to be hypertensive, have a higher cholesterol concentration, and smoke. Compared with persons with a total homocyst(e)ine concentration /=15 micromol/L had an odds ratio (OR) for myocardial infarction of 1.8 (95% confidence interval [CI], 1.2-2.9) after adjustment for cardiovascular disease risk factors. Similar associations were noted among whites (OR 1.8, 95% CI, 1.1-3.1) and blacks (OR 1.9, 95% CI, 0.8-4.2); a more modest association was noted among Mexican Americans (OR 1.2, 95% CI, 0.3-5.0). The association between total homocyst(e)ine and myocardial infarction was also more pronounced in persons without hypertension or diabetes. Almost a 2-fold increased likelihood of myocardial infarction among persons with a total homocyst(e)ine concentration >/=15 micromol/L was noted in this nationally representative survey. The magnitude of the association did not differ by race or ethnicity.

  18. Processus ultra-rapides associés à la dynamique d'émission de la protéine GFP

    Science.gov (United States)

    Didier, P.; Guidoni, L.; Schwalbach, G.; Bigot, J.-Y.

    2002-06-01

    La protéine GFP (Green Fluorescent Protein) est un marqueur très efficace, utilisable en milieu vivant. La spectroscopie femtoseconde est particulièrement bien adaptée pour comprendre les mécanismes d'émission de cette protéine, étant donné la rapidité des processus de transfert mis en jeu. Nous-présentons des résultats sur la dynamique spectro-temporelle d'émission du mutant GFPuv résolue à l'échelle de la centaine de femtosecondes. Une transition Raman à 3300 cm^{-1} ainsi que la dynamique d'etablissement du gain avec un temps caractéristique d'environ 1.5 ps ont été mis en évidence.

  19. Trening za razvijanje občutka za števila in količine pri predšolskih otrocih s posebnimi potrebami

    OpenAIRE

    Kuplenk, Petra

    2017-01-01

    Tako otroci kot tudi odrasli se z matematiko srečujemo na vsakem koraku, pa naj bo to na poti v vrtec, službo ali pa pri delu doma. Matematika vsakodnevno vpliva na naše življenje in delo. Na delovnem mestu, v vrtcu, opažam vse večje težave otrok s posebnimi potrebami na področju razvoja občutka za števila in količine. V predšolskem obdobju je namreč nujno, da otroci razvijejo občutek za števila in količine, saj vsa nadaljnja matematična znanja temeljijo na usvojenih spretnostih. V empirič...

  20. EQUIVALENCE VERSUS NON-EQUIVALENCE IN ECONOMIC TRANSLATION

    Directory of Open Access Journals (Sweden)

    Cristina, Chifane

    2012-01-01

    Full Text Available This paper aims at highlighting the fact that “equivalence” represents a concept worth revisiting and detailing upon when tackling the translation process of economic texts both from English into Romanian and from Romanian into English. Far from being exhaustive, our analysis will focus upon the problems arising from the lack of equivalence at the word level. Consequently, relevant examples from the economic field will be provided to account for the following types of non-equivalence at word level: culturespecific concepts; the source language concept is not lexicalised in the target language; the source language word is semantically complex; differences in physical and interpersonal perspective; differences in expressive meaning; differences in form; differences in frequency and purpose of using specific forms and the use of loan words in the source text. Likewise, we shall illustrate a number of translation strategies necessary to deal with the afore-mentioned cases of non-equivalence: translation by a more general word (superordinate; translation by a more neutral/less expressive word; translation by cultural substitution; translation using a loan word or loan word plus explanation; translation by paraphrase using a related word; translation by paraphrase using unrelated words; translation by omission and translation by illustration.

  1. Cyst(e)ine Is the Transport Metabolite of Assimilated Sulfur from Bundle-Sheath to Mesophyll Cells in Maize Leaves1

    Science.gov (United States)

    Burgener, Marta; Suter, Marianne; Jones, Stephanie; Brunold, Christian

    1998-01-01

    The intercellular distribution of the enzymes and metabolites of assimilatory sulfate reduction and glutathione synthesis was analyzed in maize (Zea mays L. cv LG 9) leaves. Mesophyll cells and strands of bundle-sheath cells from second leaves of 11-d-old maize seedlings were obtained by two different mechanical-isolation methods. Cross-contamination of cell preparations was determined using ribulose bisphosphate carboxylase (EC 4.1.1.39) and nitrate reductase (EC 1.6.6.1) as marker enzymes for bundle-sheath and mesophyll cells, respectively. ATP sulfurylase (EC 2.7.7.4) and adenosine 5′-phosphosulfate sulfotransferase activities were detected almost exclusively in the bundle-sheath cells, whereas GSH synthetase (EC 6.3.2.3) and cyst(e)ine, γ-glutamylcysteine, and glutathione were located predominantly in the mesophyll cells. Feeding experiments using [35S]sulfate with intact leaves indicated that cyst(e)ine was the transport metabolite of reduced sulfur from bundle-sheath to mesophyll cells. This result was corroborated by tracer experiments, which showed that isolated bundle-sheath strands fed with [35S]sulfate secreted radioactive cyst(e)ine as the sole thiol into the resuspending medium. The results presented in this paper show that assimilatory sulfate reduction is restricted to the bundle-sheath cells, whereas the formation of glutathione takes place predominantly in the mesophyll cells, with cyst(e)ine functioning as a transport metabolite between the two cell types. PMID:9536048

  2. Effect of diet and 677 C-->T 5, 10-methylenetetrahydrofolate reductase genotypes on plasma homocyst(e)ine concentrations in slovak adolescent population.

    Science.gov (United States)

    Raslová, K; Bederová, A; Gasparovic, J; Blazícek, P; Smolková, B

    2000-01-01

    The objective of this study was to evaluate the effect of diet and 677 C-->T mutation of the methylenetetrahydrofolate reductase (MTHFR) gene on plasma homocyst(e)ine concentrations in an adolescent population (113 males, age: 14.2+/-2.4 years; 202 females, age: 14.9+/-2.1 years) from a region characterized by high cardiovascular mortality. Homocyst(e)ine levels did not differ between males and females (9.4+/-3.5 and 8.9+/-3.1 micromol/l, respectively). The homozygosity for the 677 C-->T MTHFR mutation was found in 4.6 % of subjects. No differences in homocyst(e)ine levels were found between MTHFR genotypes. Analysis of the diet composition which was performed on a 24-hour daily recall basis and a food frequency questionnaire showed a low daily intake of vitamin B6 (males: 1.13 mg/66% RDA; females: 0.92 mg/61% RDA). Daily folic acid intake was 0.21 g/105% RDA in males and 0.23 g/115% RDA in females. The results of our study show that the high homocyst(e)ine levels in the adolescent population were not affected by the 677 C-->T MTHFR mutation. We conclude that an insufficient dietary intake of vitamin B6 and folic acid is responsible for this finding. This is in accord with the recommendation that the dietary allowances for folate should be reset to the originally prescribed levels of 0.4 g/day which should be sufficient to control the homocysteine levels.

  3. Low plasma taurine concentration in Newfoundland dogs is associated with low plasma methionine and cyst(e)ine concentrations and low taurine synthesis.

    Science.gov (United States)

    Backus, Robert C; Ko, Kwang Suk; Fascetti, Andrea J; Kittleson, Mark D; Macdonald, Kristin A; Maggs, David J; Berg, John R; Rogers, Quinton R

    2006-10-01

    Although taurine is not dietarily essential for dogs, taurine deficiency and dilated cardiomyopathy (DCM) are sporadically reported in large-breed dogs. Taurine status and husbandry were examined in 216 privately owned Newfoundlands, a giant dog breed with high incidence of idiopathic DCM (1.3-2.5%). Plasma taurine concentration was positively correlated (P ine (r = 0.37) and methionine (r = 0.35) concentrations and was similar across age, sex, neutering status, body weight, and body-condition scores. Plasma taurine concentration was low (ine, tryptophan, and alpha-amino-n-butyric acid concentrations than the other dogs (P ine and blood glutathione, lower (P < 0.01) de novo taurine synthesis (59 +/- 15 vs. 124 +/- 27 mg x kg(-0.75) x d(-1)), and greater (P < 0.05) fecal bile acid excretion (1.7 +/- 0.2 vs. 1.4 +/- 0.2 micromol/g). Newfoundlands would appear to have a higher dietary sulfur amino acid requirement than Beagles, a model breed used in nutrient requirement determinations.

  4. Radiation equivalency: For the radiation recall phenomenon

    International Nuclear Information System (INIS)

    Stevens, R.H.; Cole, D.A.

    1983-01-01

    Experimental and clinico-epidemiological investigations have unequivocally established the risk of an offspring in later years developing cancer after experiencing an in utero carcinogenic insult. The present studies have focused upon identifying whether the biological effects of iodine-131 and the colon carcinogen 1,2-dimethylhydrazine (DMH) when administered during pregnancy in the Fischer F344 inbred rat are remembered in the offsprings at a later age. The investigations have been based upon the premise that after exposure to a carcinogen ''foreign-like'' tumor cells develop which result in the host mounting active antitumor immune responses. The authors have now measured at 2 to 3 months post-exposure, the antitumor cell-mediated immunity (CMI) induced by intraperitoneal administration of the radionuclide or chemical at 16-18 days of gestation. Their findings indicate a positive sex relationship existing in those offsprings exposed to the radioiodine with the female being much less sensitive. In contrast, no such difference was observed between responsiveness of the males and females born from dams exposed to the DMH. Significantly, the dams exposed to either the radionuclide or DMH expressed no measurable CMI suggesting that either the fetus acted as a carcinogen trap or else the state of pregnancy altered the mother's immune system in such a fashion to no longer respond to the insult. A Radiation Equivalency value has now been determined for the transplacental DMH exposures with the calculations suggesting the fetus is significantly more sensitive (over 10 times) than the adult animals. The results of this study now demonstrate that carcinogenic memory remains for exposures to both the iodine-131 and DMH in the first offspring generation and suggest that the effects may be recalled at a later age with the expected overt results being the development of cancer

  5. Biomonitoring Equivalents for bisphenol A (BPA).

    Science.gov (United States)

    Krishnan, Kannan; Gagné, Michelle; Nong, Andy; Aylward, Lesa L; Hays, Sean M

    2010-10-01

    Recent efforts worldwide have resulted in a growing database of measured concentrations of chemicals in blood and urine samples taken from the general population. However, few tools exist to assist in the interpretation of the measured values in a health risk context. Biomonitoring Equivalents (BEs) are defined as the concentration or range of concentrations of a chemical or its metabolite in a biological medium (blood, urine, or other medium) that is consistent with an existing health-based exposure guideline. BE values are derived by integrating available data on pharmacokinetics with existing chemical risk assessments. This study reviews available health-based exposure guidance values for bisphenol A (BPA) from Health Canada, the United States Environmental Protection Agency (USEPA) and the European Food Safety Authority (EFSA). BE values were derived based on data on BPA urinary excretion in humans. The BE value corresponding to the oral provisional tolerable daily intake (pTDI) of 25 microg/kg-d from Health Canada is 1mg/L (1.3mg/g creatinine); value corresponding to the US EPA reference dose (RfD) and EFSA tolerable daily intake (TDI) estimates (both of which are equal to 50 microg/kg-d) is 2mg/L (2.6 mg/g creatinine). These values are estimates of the 24-h average urinary BPA concentrations that are consistent with steady-state exposure at the respective exposure guidance values. These BE values may be used as screening tools for evaluation of central tendency measures of population biomonitoring data for BPA in a risk assessment context and can assist in prioritization of the potential need for additional risk assessment efforts for BPA relative to other chemicals. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  6. On the calibration of photon dosemeters in the equivalent dose units

    International Nuclear Information System (INIS)

    Bregadze, Yu.I.; Isaev, B.M.; Maslyaev, P.F.

    1980-01-01

    General aspects of transition from exposure dose of photo radiation to equivalent one are considered. By determination the equivalent dose is a function of point location in an irradiated object, that is why it is necessary to know equivalent dose distribution in the human body for uniform description of the risk degree. The international electrotechnical comission recommends to measure equivalent doses at 7 and 800 mg/cm 2 depths in a tissue-equivalent ball with 30 cm diameter, calling them skin equivalent dose and depth equivalent dose, respectively, and to compare them with the permissible 500 mZ and 50 mZ a year, respectively. Practical transition to using equivalent dose for evaluation of radiation danger of being in photon radiation field of low energy should include measures on regraduating already produced dose meters, graduating the dose meters under production and developing the system of their metrologic supply [ru

  7. The need for accurate reporting and archival of data for innovative energy conversion devices: the INE database

    International Nuclear Information System (INIS)

    Bailey, P.G.; Grotz, T.; Hurtak, J.J.

    1998-01-01

    A methodology is presented to collect, document, and summarize the findings of the various experiments, motors, generators, devices, and demonstrations in the innovative energy conversion areas that have been reported in the past several years to produce very high-efficiency or so-called over-unity operation. The concepts of free-energy and over-unity devices are not new, and many examples of such devices have been built utilizing various forms of potential energy within the last 100 years, such as hydro-electric dams and nuclear reactors. As many such devices and experiments are currently being reported, it has become very important and necessary to collect the data available on each, cross-check the data with other researchers, and maintain an accurate and truthful accounting of the status of each device and experiment. The INE Database has become an internationally recognized summary of such data. This paper presents a complete description of this database, its location on the publicly available internet, provides detailed instruction on how to add new devices and experiments to this database, and also explains how to modify and update any of the existing data. Selection criteria based upon technical interest, and also on commercialization interest, allow these data to be easily ranked for comparison and reference

  8. The Source Equivalence Acceleration Method

    International Nuclear Information System (INIS)

    Everson, Matthew S.; Forget, Benoit

    2015-01-01

    Highlights: • We present a new acceleration method, the Source Equivalence Acceleration Method. • SEAM forms an equivalent coarse group problem for any spatial method. • Equivalence is also formed across different spatial methods and angular quadratures. • Testing is conducted using OpenMOC and performance is compared with CMFD. • Results show that SEAM is preferable for very expensive transport calculations. - Abstract: Fine-group whole-core reactor analysis remains one of the long sought goals of the reactor physics community. Such a detailed analysis is typically too computationally expensive to be realized on anything except the largest of supercomputers. Recondensation using the Discrete Generalized Multigroup (DGM) method, though, offers a relatively cheap alternative to solving the fine group transport problem. DGM, however, suffered from inconsistencies when applied to high-order spatial methods. While an exact spatial recondensation method was developed and provided full spatial consistency with the fine group problem, this approach substantially increased memory requirements for realistic problems. The method described in this paper, called the Source Equivalence Acceleration Method (SEAM), forms a coarse-group problem which preserves the fine-group problem even when using higher order spatial methods. SEAM allows recondensation to converge to the fine-group solution with minimal memory requirements and little additional overhead. This method also provides for consistency when using different spatial methods and angular quadratures between the coarse group and fine group problems. SEAM was implemented in OpenMOC, a 2D MOC code developed at MIT, and its performance tested against Coarse Mesh Finite Difference (CMFD) acceleration on the C5G7 benchmark problem and on a 361 group version of the problem. For extremely expensive transport calculations, SEAM was able to outperform CMFD, resulting in speed-ups of 20–45 relative to the normal power

  9. Equivalent statistics and data interpretation.

    Science.gov (United States)

    Francis, Gregory

    2017-08-01

    Recent reform efforts in psychological science have led to a plethora of choices for scientists to analyze their data. A scientist making an inference about their data must now decide whether to report a p value, summarize the data with a standardized effect size and its confidence interval, report a Bayes Factor, or use other model comparison methods. To make good choices among these options, it is necessary for researchers to understand the characteristics of the various statistics used by the different analysis frameworks. Toward that end, this paper makes two contributions. First, it shows that for the case of a two-sample t test with known sample sizes, many different summary statistics are mathematically equivalent in the sense that they are based on the very same information in the data set. When the sample sizes are known, the p value provides as much information about a data set as the confidence interval of Cohen's d or a JZS Bayes factor. Second, this equivalence means that different analysis methods differ only in their interpretation of the empirical data. At first glance, it might seem that mathematical equivalence of the statistics suggests that it does not matter much which statistic is reported, but the opposite is true because the appropriateness of a reported statistic is relative to the inference it promotes. Accordingly, scientists should choose an analysis method appropriate for their scientific investigation. A direct comparison of the different inferential frameworks provides some guidance for scientists to make good choices and improve scientific practice.

  10. Equivalent nozzle in thermomechanical problems

    International Nuclear Information System (INIS)

    Cesari, F.

    1977-01-01

    When analyzing nuclear vessels, it is most important to study the behavior of the nozzle cylinder-cylinder intersection. For the elastic field, this analysis in three dimensions is quite easy using the method of finite elements. The same analysis in the non-linear field becomes difficult for designs in 3-D. It is therefore necessary to resolve a nozzle in two dimensions equivalent to a 3-D nozzle. The purpose of the present work is to find an equivalent nozzle both with a mechanical and thermal load. This has been achieved by the analysis in three dimensions of a nozzle and a nozzle cylinder-sphere intersection, of a different radius. The equivalent nozzle will be a nozzle with a sphere radius in a given ratio to the radius of a cylinder; thus, the maximum equivalent stress is the same in both 2-D and 3-D. The nozzle examined derived from the intersection of a cylindrical vessel of radius R=191.4 mm and thickness T=6.7 mm with a cylindrical nozzle of radius r=24.675 mm and thickness t=1.350 mm, for which the experimental results for an internal pressure load are known. The structure was subdivided into 96 finite, three-dimensional and isoparametric elements with 60 degrees of freedom and 661 total nodes. Both the analysis with a mechanical load as well as the analysis with a thermal load were carried out on this structure according to the Bersafe system. The thermal load consisted of a transient typical of an accident occurring in a sodium-cooled fast reactor, with a peak of the temperature (540 0 C) for the sodium inside the vessel with an insulating argon temperature constant at 525 0 C. The maximum value of the equivalent tension was found in the internal area at the union towards the vessel side. The analysis of the nozzle in 2-D consists in schematizing the structure as a cylinder-sphere intersection, where the sphere has a given relation to the

  11. 21 CFR 26.9 - Equivalence determination.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Equivalence determination. 26.9 Section 26.9 Food... Specific Sector Provisions for Pharmaceutical Good Manufacturing Practices § 26.9 Equivalence determination... document insufficient evidence of equivalence, lack of opportunity to assess equivalence or a determination...

  12. Information Leakage from Logically Equivalent Frames

    Science.gov (United States)

    Sher, Shlomi; McKenzie, Craig R. M.

    2006-01-01

    Framing effects are said to occur when equivalent frames lead to different choices. However, the equivalence in question has been incompletely conceptualized. In a new normative analysis of framing effects, we complete the conceptualization by introducing the notion of information equivalence. Information equivalence obtains when no…

  13. Wijsman Orlicz Asymptotically Ideal -Statistical Equivalent Sequences

    Directory of Open Access Journals (Sweden)

    Bipan Hazarika

    2013-01-01

    in Wijsman sense and present some definitions which are the natural combination of the definition of asymptotic equivalence, statistical equivalent, -statistical equivalent sequences in Wijsman sense. Finally, we introduce the notion of Cesaro Orlicz asymptotically -equivalent sequences in Wijsman sense and establish their relationship with other classes.

  14. Equivalence relations of AF-algebra extensions

    Indian Academy of Sciences (India)

    In this paper, we consider equivalence relations of *-algebra extensions and describe the relationship between the isomorphism equivalence and the unitary equivalence. We also show that a certain group homomorphism is the obstruction for these equivalence relations to be the same.

  15. Mixed field dose equivalent measuring instruments

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; McDonald, J.C.; Endres, G.W.R.; Quam, W.

    1985-01-01

    In the past, separate instruments have been used to monitor dose equivalent from neutrons and gamma rays. It has been demonstrated that it is now possible to measure simultaneously neutron and gamma dose with a single instrument, the tissue equivalent proportional counter (TEPC). With appropriate algorithms dose equivalent can also be determined from the TEPC. A simple ''pocket rem meter'' for measuring neutron dose equivalent has already been developed. Improved algorithms for determining dose equivalent for mixed fields are presented. (author)

  16. Derived equivalences for group rings

    CERN Document Server

    König, Steffen

    1998-01-01

    A self-contained introduction is given to J. Rickard's Morita theory for derived module categories and its recent applications in representation theory of finite groups. In particular, Broué's conjecture is discussed, giving a structural explanation for relations between the p-modular character table of a finite group and that of its "p-local structure". The book is addressed to researchers or graduate students and can serve as material for a seminar. It surveys the current state of the field, and it also provides a "user's guide" to derived equivalences and tilting complexes. Results and proofs are presented in the generality needed for group theoretic applications.

  17. Calculation methods for determining dose equivalent

    International Nuclear Information System (INIS)

    Endres, G.W.R.; Tanner, J.E.; Scherpelz, R.I.; Hadlock, D.E.

    1987-11-01

    A series of calculations of neutron fluence as a function of energy in an anthropomorphic phantom was performed to develop a system for determining effective dose equivalent for external radiation sources. Critical organ dose equivalents are calculated and effective dose equivalents are determined using ICRP-26 [1] methods. Quality factors based on both present definitions and ICRP-40 definitions are used in the analysis. The results of these calculations are presented and discussed. The effective dose equivalent determined using ICRP-26 methods is significantly smaller than the dose equivalent determined by traditional methods. No existing personnel dosimeter or health physics instrument can determine effective dose equivalent. At the present time, the conversion of dosimeter response to dose equivalent is based on calculations for maximal or ''cap'' values using homogeneous spherical or cylindrical phantoms. The evaluated dose equivalent is, therefore, a poor approximation of the effective dose equivalent as defined by ICRP Publication 26. 3 refs., 2 figs., 1 tab

  18. 10 CFR 835.203 - Combining internal and external equivalent doses.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Combining internal and external equivalent doses. 835.203 Section 835.203 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External Exposure § 835.203 Combining internal and external equivalent doses. (a) The total effective dose...

  19. Trans labilization of am(m)ine ligands from platinum(II) complexes by cancer cell extracts.

    Science.gov (United States)

    Kasherman, Yonit; Sturup, Stefan; Gibson, Dan

    2009-03-01

    Cisplatin, cis-[Pt(NH(3))(2)Cl(2)], is an effective anticancer agent in wide clinical use whose efficacy is affected by cellular interactions with sulfur-containing nucleophiles. These interactions can potentially enhance the efficacy of the drug by mediating its delivery to nuclear DNA or inactivate the drug by binding to it irreversibly or by labilizing the NH(3) ligands. Despite the potential importance of trans-labilization reactions in the mechanism of action of the drug, few detailed studies on trans labilization of the ammines have been conducted. We used 2D NMR to show that some trans labilization occurs in proliferating cells and that aqueous extracts of cancer cells labilized 20% of the amine ligands of cis-[PtCl(2)((13)CH(3)NH(2))(2)] after a 12-h incubation. Both low molecular mass nucleophiles (less than 3 kDa) and high molecular mass nucleophiles (more than 3 kDa) labilize the amines with similar efficiency. Studies with model compounds show that thiols and thioethers bind to platinum(II) at similar rates, but thioethers are significantly more efficient at labilizing the am(m)ine at lower pH. N-Acetylcysteine is a more efficient trans-labilizer than glutathione, suggesting that the displacement of the amine proceeds through an associative mechanism. The lag time, the time that elapses from the formation of the Pt-S bond till the release of the amine trans to the sulfur, depends on the pH (for thiols), increasing at lower pH. Quantification of the platinum adducts obtained from incubation of cisplatin with cell extracts indicates that two thirds of the platinum is bound to cellular components with molecular mass greater than 3 kDa.

  20. HIGH IONIZATION SPECIES IN THE NEARBY INTERSTELLAR MEDIUM FROM AN EXHAUSTIVE ANALYSIS OF THE IUE INES DATABASE

    Energy Technology Data Exchange (ETDEWEB)

    Freire Ferrero, R.; Halbwachs, J.-L. [Observatoire Astronomique, Universite de Strasbourg, 11 rue de l' Universite, 67.000 Strasbourg (France); Morales Duran, C.; Cabo Cubeiro, A. M., E-mail: rubens.freire@astro.unistra.fr, E-mail: jean-louis.halbwachs@astro.unistra.fr, E-mail: morales@cab.inta-csic.es, E-mail: amcabo@cab.inta-csic.es [LAEX, Centro de Astrobiologia (CAB, CSIC-INTA), LAEFF, European Space Astronomy Centre, P.O. Box 78, 28691 Villanueva de la Canada, Madrid (Spain)

    2012-02-15

    Main-sequence (MS) and giant late-B and early-A type stars are the best targets for searching for nearby interstellar (IS) Si IV and C IV resonance lines because they are not able to produce them, either in atmospheric layers or in their circumstellar environment, and because many stars of these spectral types are nearby and located in the local interstellar medium (LISM). In addition, the use of certain stars hotter than B6 can lead to misinterpretations (e.g., alpha Arae). This work analyzes the reliable Short-Wavelength Prime high-resolution UV spectra of 558 B6-A9 type stars observed by the International Ultraviolet Explorer at distances lower than 400 pc from the Sun. For the first time, this work utilizes the entire INES database to extract stellar and IS information in a systematic way from homogeneous data. Stars were classified into seven groups: normal (MS and subgiant), giant, peculiar, emission line, Algols, pre-main sequence or Herbig Ae/Be, and shell stars. Only 10 normal stars, located beyond 90 pc, show weak Si IV and C IV absorptions and are clustered around the direction of Sco-Cen, while 85 located closer than 90 pc, as well as another 89 beyond 90 pc, do not show any absorptions at all. We conclude that these highly ionized species originate most probably in the LISM, at 90 pc from the Sun, corresponding to the warm interaction zone (IZ), where the expanding Loop I super-shell and the Local Bubble collide. We base our results on a robust statistical analysis of both spectral types and spatial distributions of the different stellar groups we defined. Our estimated column densities N of both ions are similar to those obtained by other authors for distant stars, suggesting that these absorptions concentrate fundamentally in the IZ. A logarithmic correlation between N and the distance D confirms these results.

  1. Is the dose equivalent index a quantity to be measured

    International Nuclear Information System (INIS)

    Wagner, S.R.

    1980-01-01

    ICRP introduced the concept of Effective Dose Equivalent H(sub)E and fixed the basic limits of radiation exposure in terms of H(sub)I. As H(sub)E cannot be measured, ICRP stated that with external exposure to penetrating radiation the limitation of the Dose Equivalent Index H(sub)I would afford at least as good a level of protection. However, difficulties arise in measuring H(sub)I and in calibrating instruments in terms of H(sub)I, since the height and location of the dose equivalent maximum in the sphere which is the phantom used in the definition of H(sub)I, depend on the energy and the angular distribution of the incident radiation. That is, H(sub)I is not an additive quantity relative to the partial H(sub)I(sub)i-values of the different energy and angular components. Hence, 1) the distribution of dose equivalent in the sphere must be measured in full for a determination of H(sub)I, and 2) it is not possible to calibrate an instrument which does not exhibit the scattering and absorption properties of the sphere, consistently for arbitrary radiation fields in terms of H(sub)I. Thus the calibration in an unidirectional beam would infer an uncertainty which may amount to a factor of up to 4. This would hardly be tolerable as a base for radiation protection provisions. An alternative is to introduce operational quantities which are additive, e.g. 1) the sum of maxima of the dose equivalent distributions in the sphere produced by different radiation components, and 2) the mean dose equivalent in the sphere. Their relation to H(sub)E for different types of radiation and consequences on secondary limits are discussed. (H.K.)

  2. Foreword: Biomonitoring Equivalents special issue.

    Science.gov (United States)

    Meek, M E; Sonawane, B; Becker, R A

    2008-08-01

    The challenge of interpreting results of biomonitoring for environmental chemicals in humans is highlighted in this Foreword to the Biomonitoring Equivalents (BEs) special issue of Regulatory Toxicology and Pharmacology. There is a pressing need to develop risk-based tools in order to empower scientists and health professionals to interpret and communicate the significance of human biomonitoring data. The BE approach, which integrates dosimetry and risk assessment methods, represents an important advancement on the path toward achieving this objective. The articles in this issue, developed as a result of an expert panel meeting, present guidelines for derivation of BEs, guidelines for communication using BEs and several case studies illustrating application of the BE approach for specific substances.

  3. Radiological equivalent of chemical pollutants

    International Nuclear Information System (INIS)

    Medina, V.O.

    1982-01-01

    The development of the peaceful uses of nuclear energy has caused continued effort toward public safety through radiation health protection measures and nuclear management practices. However, concern has not been focused on the development specifically in the operation of chemical pestrochemical industries as well as other industrial processes brought about by technological advancements. This article presents the comparison of the risk of radiation and chemicals. The methods used for comparing the risks of late effects of radiation and chemicals are considered at three levels. (a) as a frame of reference to give an impression of resolving power of biological tests; (b) as methods to quantify risks; (c) as instruments for an epidemiological survey of human populations. There are marked dissimilarities between chemicals and radiation and efforts to interpret chemical activity may not be achieved. Applicability of the concept of rad equivalence has many restrictions and as pointed out this approach is not an established one. (RTD)

  4. Tissue equivalence in neutron dosimetry

    International Nuclear Information System (INIS)

    Nutton, D.H.; Harris, S.J.

    1980-01-01

    A brief review is presented of the essential features of neutron tissue equivalence for radiotherapy and gives the results of a computation of relative absorbed dose for 14 MeV neutrons, using various tissue models. It is concluded that for the Bragg-Gray equation for ionometric dosimetry it is not sufficient to define the value of W to high accuracy and that it is essential that, for dosimetric measurements to be applicable to real body tissue to an accuracy of better than several per cent, a correction to the total absorbed dose must be made according to the test and tissue atomic composition, although variations in patient anatomy and other radiotherapy parameters will often limit the benefits of such detailed dosimetry. (U.K.)

  5. Expanding the Interaction Equivalency Theorem

    Directory of Open Access Journals (Sweden)

    Brenda Cecilia Padilla Rodriguez

    2015-06-01

    Full Text Available Although interaction is recognised as a key element for learning, its incorporation in online courses can be challenging. The interaction equivalency theorem provides guidelines: Meaningful learning can be supported as long as one of three types of interactions (learner-content, learner-teacher and learner-learner is present at a high level. This study sought to apply this theorem to the corporate sector, and to expand it to include other indicators of course effectiveness: satisfaction, knowledge transfer, business results and return on expectations. A large Mexican organisation participated in this research, with 146 learners, 30 teachers and 3 academic assistants. Three versions of an online course were designed, each emphasising a different type of interaction. Data were collected through surveys, exams, observations, activity logs, think aloud protocols and sales records. All course versions yielded high levels of effectiveness, in terms of satisfaction, learning and return on expectations. Yet, course design did not dictate the types of interactions in which students engaged within the courses. Findings suggest that the interaction equivalency theorem can be reformulated as follows: In corporate settings, an online course can be effective in terms of satisfaction, learning, knowledge transfer, business results and return on expectations, as long as (a at least one of three types of interaction (learner-content, learner-teacher or learner-learner features prominently in the design of the course, and (b course delivery is consistent with the chosen type of interaction. Focusing on only one type of interaction carries a high risk of confusion, disengagement or missed learning opportunities, which can be managed by incorporating other forms of interactions.

  6. Quantitative comparison of mutagenic hazards: rad-equivalences

    International Nuclear Information System (INIS)

    1980-01-01

    The present situation concerning the problem of estimating genetic risks associated with the exposure of living beings, including man, to chemical compounds present in the environment is defined. Since these compounds affect the genetic material of cells by reactions similar to those produced by radiations, attempts have been made to establish rad-equivalences for some of these substances. This idea is discussed through the different publications mentioned [fr

  7. Equivalent damage of loads on pavements

    CSIR Research Space (South Africa)

    Prozzi, JA

    2009-05-26

    Full Text Available This report describes a new methodology for the determination of Equivalent Damage Factors (EDFs) of vehicles with multiple axle and wheel configurations on pavements. The basic premise of this new procedure is that "equivalent pavement response...

  8. Investigation of Equivalent Circuit for PEMFC Assessment

    International Nuclear Information System (INIS)

    Myong, Kwang Jae

    2011-01-01

    Chemical reactions occurring in a PEMFC are dominated by the physical conditions and interface properties, and the reactions are expressed in terms of impedance. The performance of a PEMFC can be simply diagnosed by examining the impedance because impedance characteristics can be expressed by an equivalent electrical circuit. In this study, the characteristics of a PEMFC are assessed using the AC impedance and various equivalent circuits such as a simple equivalent circuit, equivalent circuit with a CPE, equivalent circuit with two RCs, and equivalent circuit with two CPEs. It was found in this study that the characteristics of a PEMFC could be assessed using impedance and an equivalent circuit, and the accuracy was highest for an equivalent circuit with two CPEs

  9. 46 CFR 175.540 - Equivalents.

    Science.gov (United States)

    2010-10-01

    ... Safety Management (ISM) Code (IMO Resolution A.741(18)) for the purpose of determining that an equivalent... Organization (IMO) “Code of Safety for High Speed Craft” as an equivalent to compliance with applicable...

  10. Pristup uzurpacijama zemljišta na teritoriji općine Maglaj : Approach of land usurpation of municipality of Maglaj theritory

    Directory of Open Access Journals (Sweden)

    Faris Habibović

    2012-12-01

    Full Text Available Rad na temu „Pristup uzurpacijama zemljišta na teritoriji općine Maglaj“obrađuje postupak raspravljanja uzurpacija na teritoriji općine Maglaj uz korištenje odgovarajućih softverskih aplikacija. U okviru rada je opisan postupak povlačenja granične linije između šuma i šumskog zemljišta sa jedne strane i poljoprivrednog zemljišta sa druge strane, a potom su date karakteristike uzurpiranog zemljišta-parcela. Granična linija je na planovima povučena u AutoCAD programskom paketu, a baza podataka kao i pregledna skica za sve šumske komplekse izrađena koristeći softversku aplikaciju ArcGIS. U radu su obrađene tri katastarske općine (k.o. Ošve, k.o. Moševac i k.o. Ravna. : This paper deals with the process of discussing land usurpation in the territory of Maglaj municipality using appropriate software applications. Drawing procedure of the boundary line between the forest (forest land and farmland is described. Later are given characteristics of usurped land - lots. Boundary line is drawn on the plans in AutoCAD software, and the database and review drafts of all forest complexes have been made using ArcGIS software application. In this paper three cadastral municipalities are processed (cadastral municipality Ošve, cadastral municipality Moševac and cadastral municipality Ravna.

  11. Some spectral equivalences between Schroedinger operators

    International Nuclear Information System (INIS)

    Dunning, C; Hibberd, K E; Links, J

    2008-01-01

    Spectral equivalences of the quasi-exactly solvable sectors of two classes of Schroedinger operators are established, using Gaudin-type Bethe ansatz equations. In some instances the results can be extended leading to full isospectrality. In this manner we obtain equivalences between PT-symmetric problems and Hermitian problems. We also find equivalences between some classes of Hermitian operators

  12. Les sources de protéines dans l’alimentation du bétail en France : la place des oléoprotéagineux

    Directory of Open Access Journals (Sweden)

    Peyronnet Corinne

    2014-07-01

    Full Text Available En France, les aliments concentrés totalisent 30 millions de tonnes de matières premières parmi lesquelles 64 % sont des céréales et 22 % des tourteaux d’oléagineux. Le déficit français en matières riches en protéines (dosant plus de 15 % de protéines qui était d’environ 70 % dans les années 1980 a baissé en dessous de 40 % successivement grâce au développement du pois dans les années 1990 puis du colza depuis les années 2000 avec des surfaces totales cultivées de 2,5 millions d’hectares environ. Le tourteau de soja reste le premier tourteau utilisé en France mais ses importations baissent, notamment depuis 2009, et il n’a représenté que 3,3 millions de tonnes sur la campagne 2012/2013. L’utilisation du tourteau de soja non OGM diminue également avec 0,6 million de tonnes en 2012 contre 1,2 en 2002. Les tourteaux de colza et tournesol ont quant à eux atteint respectivement 2,3 et 1,4 millions de tonnes en 2012/2013 parmi lesquels 700 000 tonnes de tourteau de tournesol High pro (à 36 % de protéines importées de la zone Mer noire et 600 000 tonnes de différentes qualités produites en France. Depuis 2013, des tourteaux de tournesol High pro sont également produits en France à Bassens. Les prix des MRP suivent le marché mondial du tourteau de soja mais la demande française pour des matières premières non OGM permet une meilleure valorisation des sources de protéines locales.

  13. Vpliv albanske manjšine na notranjo varnost Republike Makedonije : diplomsko delo visokošolskega strokovnega študija Varnost in policijsko delo

    OpenAIRE

    Mladkovič, Karl

    2013-01-01

    Z razpadom SFRJ leta 1991 so na njenem območju nastale nove, samostojne in neodvisne države. Ena najmanj pripravljenih za samostojno pot je bila Republika Makedonija. Zaradi zgodovinskih dejstev in okoliščin je bila in je še vedno, ne tako vojaško, kot politično in ekonomsko ogrožena s strani svojih sosed Bolgarije, ki ne priznava Makedoncev kot narod in Makedonščine kot samostojnega jezika, Srbije, ki prav tako ne priznavala Makedonije kot samostojnega naroda in njene avtokefalne pravoslavne...

  14. Design, synthesis and anticancer activity of diam(m)ine platinum(II) complexes bearing a small-molecular cell apoptosis inducer dichloroacetate.

    Science.gov (United States)

    Liu, Weiping; Jiang, Jing; Xu, Yongping; Hou, Shuqian; Sun, Liping; Ye, Qingsong; Lou, Liguang

    2015-05-01

    Four new diam(m)ine platinum complexes containing the dichloroacetate moiety in 3-dichoroacetoxylcyclobutane-1,1-dicarboxylate as the leaving group were synthesized, characterized by elemental analysis as well as by ESI(+)-MS (electrospray ionization mass spectrometry in positive mode), FT-IR, (1)H- and (13)C-NMR, and evaluated for their in vitro anticancer activity against human lung cancer cell line (A549) and ovarian cancer cell lines (SK-OV-3, SK-OV-3/DDP). Diam(m)ines used in the present study belong to the carriers of six clinically approved platinum drugs. Among the complexes synthesized, complex 2, cis-[Pt(II)(1R,2R-diaminocyclohexane)·(3-dichoroacetoxylcyclobutane-1,1-dicarboxylate)] is the most promising in terms of water solubility and potential of being totally devoid of cross-drug resistance with cisplatin. Therefore, complex 2 was selected for the dichloroacetate release test. The test shows dichloroacetate can be efficiently released from complex 2 under physiological conditions via the hydrolysis of an ester bond bridging the dichloroacetate moiety and platinum pharmacophores together. Our study supports the further evaluation of this complex as a drug candidate. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Validity of the Aluminum Equivalent Approximation in Space Radiation Shielding

    Science.gov (United States)

    Badavi, Francis F.; Adams, Daniel O.; Wilson, John W.

    2009-01-01

    The origin of the aluminum equivalent shield approximation in space radiation analysis can be traced back to its roots in the early years of the NASA space programs (Mercury, Gemini and Apollo) wherein the primary radiobiological concern was the intense sources of ionizing radiation causing short term effects which was thought to jeopardize the safety of the crew and hence the mission. Herein, it is shown that the aluminum equivalent shield approximation, although reasonably well suited for that time period and to the application for which it was developed, is of questionable usefulness to the radiobiological concerns of routine space operations of the 21 st century which will include long stays onboard the International Space Station (ISS) and perhaps the moon. This is especially true for a risk based protection system, as appears imminent for deep space exploration where the long-term effects of Galactic Cosmic Ray (GCR) exposure is of primary concern. The present analysis demonstrates that sufficiently large errors in the interior particle environment of a spacecraft result from the use of the aluminum equivalent approximation, and such approximations should be avoided in future astronaut risk estimates. In this study, the aluminum equivalent approximation is evaluated as a means for estimating the particle environment within a spacecraft structure induced by the GCR radiation field. For comparison, the two extremes of the GCR environment, the 1977 solar minimum and the 2001 solar maximum, are considered. These environments are coupled to the Langley Research Center (LaRC) deterministic ionized particle transport code High charge (Z) and Energy TRaNsport (HZETRN), which propagates the GCR spectra for elements with charges (Z) in the range I aluminum equivalent approximation for a good polymeric shield material such as genetic polyethylene (PE). The shield thickness is represented by a 25 g/cm spherical shell. Although one could imagine the progression to greater

  16. Imag(ining Sardinia

    Directory of Open Access Journals (Sweden)

    Giorgia Alù

    2014-12-01

    Full Text Available Review of: Maria Bonaria Urban, Sardinia on Screen. The Construction of the Sardinian Character in Italian Cinema, Amsterdam–New York, Rodopi, 579 p., 2013, ISBN: 9789042037502, € 120 / US$ 168; eBook: 9789401210010, € 108 / US$ 151.

  17. Risky Bu$ine$$

    Science.gov (United States)

    Galuszka, Peter

    2006-01-01

    Hedge funds are the rock stars of today's financial world. These slightly regulated pools of equity, which are open only to rich players, are managed through secretive and sophisticated investment strategies. Although the risks are high, so are the potential benefits. Despite the risks, many colleges and universities have chosen to invest heavily…

  18. Individual monitoring of external exposure in terms of personal dose equivalent, H{sub p}(d); Dosimetria personale esterna in termini di equivalente di dose personale, H{sub p}(d). Atti. Giornata di studio, Bologna, 28 febbraio 2001

    Energy Technology Data Exchange (ETDEWEB)

    Fantuzzi, E. [ENEA, Div. Protezione dell' Uomo e degli Ecosistemi, Centro Ricerche Ezio Clementel, Bologna (Italy)

    2001-07-01

    The institute for Radiation Protection of ENEA - Bologna has organised a one day-workshop on the subject: Individual monitoring of external exposure in terms of personal dose equivalent, H{sub p}(d). The aim of the workshop was the discussion of the new implications and modifications to be expected in the routine individual monitoring of external radiation, due to the issue of the Decree 241/00 (G.U. 31/8/2000) in charge since 01/01/2001. The decree set up in Italian law the standards contained in the European Directive EURATOM 96/29-Basic Standards for the Protection of Health of Workers and the General Public against Dangers arising from Ionizing Radiation. Among others, the definition of the operational quantities for external radiation for personal and environmental monitoring, H{sub p}(d) e H{sup *}(d) respectively as defined by ICRU (International Commission for Radiation Units and Measurements), requires to update the methods of measurements and calibration of the personal dosemeters and environmental monitors. This report collects the papers presented at the workshop dealing with the Personal Dose Equivalent, H{sub p}(d), the conversion coefficients, H{sub p}(d)/K{sub a} e H{sub p}(d)/{sub ,} obtained through Monte Carlo calculations published by ICRU and ICRP (International Commission for Radiation Protection), the new calibration procedures and the practical implication in the routine of individual monitoring in terms of H{sub p}(d). Eventually, in the last chapter, the answers to Frequently Asked Questions (FAQ) are briefly reported. [Italian] L'Istituto per la Radioprotezione dell'ENEA di Bologna ha organizzato una giornata di studio Dosimetria personale esterna in termini di equivalente di dose personale, H{sub p}(d). Lo scopo della giornata e' stato quello di discutere le novita' e le modifiche da apportare alle pratiche di monitoraggio dell'esposizione esterna alle radiazioni ionizzanti, a seguito dell'entrata in vigore

  19. The Complexity of Identifying Large Equivalence Classes

    DEFF Research Database (Denmark)

    Skyum, Sven; Frandsen, Gudmund Skovbjerg; Miltersen, Peter Bro

    1999-01-01

    We prove that at least 3k−4/k(2k−3)(n/2) – O(k)equivalence tests and no more than 2/k (n/2) + O(n) equivalence tests are needed in the worst case to identify the equivalence classes with at least k members in set of n elements. The upper bound is an improvement by a factor 2 compared to known res...

  20. Equivalent Simplification Method of Micro-Grid

    OpenAIRE

    Cai Changchun; Cao Xiangqin

    2013-01-01

    The paper concentrates on the equivalent simplification method for the micro-grid system connection into distributed network. The equivalent simplification method proposed for interaction study between micro-grid and distributed network. Micro-grid network, composite load, gas turbine synchronous generation, wind generation are equivalent simplification and parallel connect into the point of common coupling. A micro-grid system is built and three phase and single phase grounded faults are per...

  1. Calculation methods for determining dose equivalent

    International Nuclear Information System (INIS)

    Endres, G.W.R.; Tanner, J.E.; Scherpelz, R.I.; Hadlock, D.E.

    1988-01-01

    A series of calculations of neutron fluence as a function of energy in an anthropomorphic phantom was performed to develop a system for determining effective dose equivalent for external radiation sources. critical organ dose equivalents are calculated and effective dose equivalents are determined using ICRP-26 methods. Quality factors based on both present definitions and ICRP-40 definitions are used in the analysis. The results of these calculations are presented and discussed

  2. Equivalences of real submanifolds in complex space.

    OpenAIRE

    ZAITSEV, DMITRI

    2001-01-01

    PUBLISHED We show that for any real-analytic submanifold M in CN there is a proper real-analytic subvariety V contained in M such that for any p ? M \\ V , any real-analytic submanifold M? in CN, and any p? ? M?, the germs of the submanifolds M and M? at p and p? respectively are formally equivalent if and only if they are biholomorphically equivalent. More general results for k-equivalences are also stated and proved.

  3. Relations of equivalence of conditioned radioactive waste

    International Nuclear Information System (INIS)

    Kumer, L.; Szeless, A.; Oszuszky, F.

    1982-01-01

    A compensation for the wastes remaining with the operator of a waste management center, to be given by the agent having caused the waste, may be assured by effecting a financial valuation (equivalence) of wastes. Technically and logically, this equivalence between wastes (or specifically between different waste categories) and financial valuation has been established as reasonable. In this paper, the possibility of establishing such equivalences are developed, and their suitability for waste management concepts is quantitatively expressed

  4. Behavioural equivalence for infinite systems - Partially decidable!

    DEFF Research Database (Denmark)

    Sunesen, Kim; Nielsen, Mogens

    1996-01-01

    languages with two generalizations based on traditional approaches capturing non-interleaving behaviour, pomsets representing global causal dependency, and locality representing spatial distribution of events. We first study equivalences on Basic Parallel Processes, BPP, a process calculus equivalent...... of processes between BPP and TCSP, not only are the two equivalences different, but one (locality) is decidable whereas the other (pomsets) is not. The decidability result for locality is proved by a reduction to the reachability problem for Petri nets....

  5. Equivalence in Bilingual Lexicography: Criticism and Suggestions*

    Directory of Open Access Journals (Sweden)

    Herbert Ernst Wiegand

    2011-10-01

    Full Text Available

    Abstract: A reminder of general problems in the formation of terminology, as illustrated by theGerman Äquivalence (Eng. equivalence and äquivalent (Eng. equivalent, is followed by a critical discussionof the concept of equivalence in contrastive lexicology. It is shown that especially the conceptof partial equivalence is contradictory in its different manifestations. Consequently attemptsare made to give a more precise indication of the concept of equivalence in the metalexicography,with regard to the domain of the nominal lexicon. The problems of especially the metalexicographicconcept of partial equivalence as well as that of divergence are fundamentally expounded.In conclusion the direction is indicated to find more appropriate metalexicographic versions of theconcept of equivalence.

    Keywords: EQUIVALENCE, LEXICOGRAPHIC EQUIVALENT, PARTIAL EQUIVALENCE,CONGRUENCE, DIVERGENCE, CONVERGENCE, POLYDIVERGENCE, SYNTAGM-EQUIVALENCE,ZERO EQUIVALENCE, CORRESPONDENCE

    Abstrakt: Äquivalenz in der zweisprachigen Lexikographie: Kritik und Vorschläge.Nachdem an allgemeine Probleme der Begriffsbildung am Beispiel von dt. Äquivalenzund dt. äquivalent erinnert wurde, wird zunächst auf Äquivalenzbegriffe in der kontrastiven Lexikologiekritisch eingegangen. Es wird gezeigt, dass insbesondere der Begriff der partiellen Äquivalenzin seinen verschiedenen Ausprägungen widersprüchlich ist. Sodann werden Präzisierungenzu den Äquivalenzbegriffen in der Metalexikographie versucht, die sich auf den Bereich der Nennlexikbeziehen. Insbesondere der metalexikographische Begriff der partiellen Äquivalenz sowie derder Divergenz werden grundsätzlich problematisiert. In welche Richtung man gehen kann, umangemessenere metalexikographische Fassungen des Äquivalenzbegriffs zu finden, wird abschließendangedeutet.

    Stichwörter: ÄQUIVALENZ, LEXIKOGRAPHISCHES ÄQUIVALENT, PARTIELLE ÄQUIVALENZ,KONGRUENZ, DIVERGENZ, KONVERGENZ, POLYDIVERGENZ

  6. Investigation of 1-cm dose equivalent for photons behind shielding materials

    International Nuclear Information System (INIS)

    Hirayama, Hideo; Tanaka, Shun-ichi

    1991-03-01

    The ambient dose equivalent at 1-cm depth, assumed equivalent to the 1-cm dose equivalent in practical dose estimations behind shielding slabs of water, concrete, iron or lead for normally incident photons having various energies was calculated by using conversion factors for a slab phantom. It was compared with the 1-cm depth dose calculated with the Monte Carlo code EGS4. It was concluded from this comparison that the ambient dose equivalent calculated by using the conversion factors for the ICRU sphere could be used for the evaluation of the 1-cm dose equivalent for the sphere phantom within 20% errors. Average and practical conversion factors are defined as the conversion factors from exposure to ambient dose equivalent in a finite slab or an infinite one, respectively. They were calculated with EGS4 and the discrete ordinates code PALLAS. The exposure calculated with simple estimation procedures such as point kernel methods can be easily converted to ambient dose equivalent by using these conversion factors. The maximum value between 1 and 30 mfp can be adopted as the conversion factor which depends only on material and incident photon energy. This gives the ambient dose equivalent on the safe side. 13 refs., 7 figs., 2 tabs

  7. Determination of dose equivalent and risk in thorium cycle

    International Nuclear Information System (INIS)

    Ney, C.L.V.N.

    1988-01-01

    In these report are presented the calculations of dose equivalent and risk, utilizing the dosimetric model described in publication 30 of the International Comission on Radiological Protection. This information was obtained by the workers of the thorium cycle, employed at the Praia and Santo Amaro Facilities, by assessing the quantity and concentration of thorium in the air. The samples and the number of measurements were established through design of experiments techniques, and the results were evaluated with the aid of variance analysis. The estimater of dose equivalent for internal and external radiation exposure and risk associated were compared with the maximum recommended limits. The results indicate the existence of operation areas whose values were above those limits, requiring so an improvement in the procedures and services in order to meet the requirements of the radiological protetion. (author) [pt

  8. Equivalent drawbead performance in deep drawing simulations

    NARCIS (Netherlands)

    Meinders, Vincent T.; Geijselaers, Hubertus J.M.; Huetink, Han

    1999-01-01

    Drawbeads are applied in the deep drawing process to improve the control of the material flow during the forming operation. In simulations of the deep drawing process these drawbeads can be replaced by an equivalent drawbead model. In this paper the usage of an equivalent drawbead model in the

  9. On uncertainties in definition of dose equivalent

    International Nuclear Information System (INIS)

    Oda, Keiji

    1995-01-01

    The author has entertained always the doubt that in a neutron field, if the measured value of the absorbed dose with a tissue equivalent ionization chamber is 1.02±0.01 mGy, may the dose equivalent be taken as 10.2±0.1 mSv. Should it be 10.2 or 11, but the author considers it is 10 or 20. Even if effort is exerted for the precision measurement of absorbed dose, if the coefficient being multiplied to it is not precise, it is meaningless. [Absorbed dose] x [Radiation quality fctor] = [Dose equivalent] seems peculiar. How accurately can dose equivalent be evaluated ? The descriptions related to uncertainties in the publications of ICRU and ICRP are introduced, which are related to radiation quality factor, the accuracy of measuring dose equivalent and so on. Dose equivalent shows the criterion for the degree of risk, or it is considered only as a controlling quantity. The description in the ICRU report 1973 related to dose equivalent and its unit is cited. It was concluded that dose equivalent can be considered only as the absorbed dose being multiplied by a dimensionless factor. The author presented the questions. (K.I.)

  10. Orientifold Planar Equivalence: The Chiral Condensate

    DEFF Research Database (Denmark)

    Armoni, Adi; Lucini, Biagio; Patella, Agostino

    2008-01-01

    The recently introduced orientifold planar equivalence is a promising tool for solving non-perturbative problems in QCD. One of the predictions of orientifold planar equivalence is that the chiral condensates of a theory with $N_f$ flavours of Dirac fermions in the symmetric (or antisymmetric...

  11. 7 CFR 1005.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1005.54 Section 1005.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1005.54 Equivalent price. See § 1000.54. Uniform Prices ...

  12. 7 CFR 1126.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1126.54 Section 1126.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1126.54 Equivalent price. See § 1000.54. Producer Price Differential ...

  13. 7 CFR 1001.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1001.54 Section 1001.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1001.54 Equivalent price. See § 1000.54. Producer Price Differential ...

  14. 7 CFR 1032.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1032.54 Section 1032.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1032.54 Equivalent price. See § 1000.54. Producer Price Differential ...

  15. 7 CFR 1124.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1124.54 Section 1124.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Class Prices § 1124.54 Equivalent price. See § 1000.54. Producer Price Differential ...

  16. 7 CFR 1030.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1030.54 Section 1030.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1030.54 Equivalent price. See § 1000.54. ...

  17. 7 CFR 1033.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1033.54 Section 1033.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1033.54 Equivalent price. See § 1000.54. Producer Price Differential ...

  18. 7 CFR 1131.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1131.54 Section 1131.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1131.54 Equivalent price. See § 1000.54. Uniform Prices ...

  19. 7 CFR 1006.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1006.54 Section 1006.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1006.54 Equivalent price. See § 1000.54. Uniform Prices ...

  20. 7 CFR 1007.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1007.54 Section 1007.54 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Handling Class Prices § 1007.54 Equivalent price. See § 1000.54. Uniform Prices ...

  1. 7 CFR 1000.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1000.54 Section 1000.54 Agriculture... Prices § 1000.54 Equivalent price. If for any reason a price or pricing constituent required for computing the prices described in § 1000.50 is not available, the market administrator shall use a price or...

  2. Finding small equivalent decision trees is hard

    NARCIS (Netherlands)

    Zantema, H.; Bodlaender, H.L.

    2000-01-01

    Two decision trees are called decision equivalent if they represent the same function, i.e., they yield the same result for every possible input. We prove that given a decision tree and a number, to decide if there is a decision equivalent decision tree of size at most that number is NPcomplete. As

  3. What is Metaphysical Equivalence? | Miller | Philosophical Papers

    African Journals Online (AJOL)

    Theories are metaphysically equivalent just if there is no fact of the matter that could render one theory true and the other false. In this paper I argue that if we are judiciously to resolve disputes about whether theories are equivalent or not, we need to develop testable criteria that will give us epistemic access to the obtaining ...

  4. EQUIVALENT MODELS IN COVARIANCE STRUCTURE-ANALYSIS

    NARCIS (Netherlands)

    LUIJBEN, TCW

    1991-01-01

    Defining equivalent models as those that reproduce the same set of covariance matrices, necessary and sufficient conditions are stated for the local equivalence of two expanded identified models M1 and M2 when fitting the more restricted model M0. Assuming several regularity conditions, the rank

  5. Equivalence in Ventilation and Indoor Air Quality

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max; Walker, Iain; Logue, Jennifer

    2011-08-01

    We ventilate buildings to provide acceptable indoor air quality (IAQ). Ventilation standards (such as American Society of Heating, Refrigerating, and Air-Conditioning Enginners [ASHRAE] Standard 62) specify minimum ventilation rates without taking into account the impact of those rates on IAQ. Innovative ventilation management is often a desirable element of reducing energy consumption or improving IAQ or comfort. Variable ventilation is one innovative strategy. To use variable ventilation in a way that meets standards, it is necessary to have a method for determining equivalence in terms of either ventilation or indoor air quality. This study develops methods to calculate either equivalent ventilation or equivalent IAQ. We demonstrate that equivalent ventilation can be used as the basis for dynamic ventilation control, reducing peak load and infiltration of outdoor contaminants. We also show that equivalent IAQ could allow some contaminants to exceed current standards if other contaminants are more stringently controlled.

  6. Beyond Language Equivalence on Visibly Pushdown Automata

    DEFF Research Database (Denmark)

    Srba, Jiri

    2009-01-01

    We study (bi)simulation-like preorder/equivalence checking on the class of visibly pushdown automata and its natural subclasses visibly BPA (Basic Process Algebra) and visibly one-counter automata. We describe generic methods for proving complexity upper and lower bounds for a number of studied...... preorders and equivalences like simulation, completed simulation, ready simulation, 2-nested simulation preorders/equivalences and bisimulation equivalence. Our main results are that all the mentioned equivalences and preorders are EXPTIME-complete on visibly pushdown automata, PSPACE-complete on visibly...... one-counter automata and P-complete on visibly BPA. Our PSPACE lower bound for visibly one-counter automata improves also the previously known DP-hardness results for ordinary one-counter automata and one-counter nets. Finally, we study regularity checking problems for visibly pushdown automata...

  7. Assessment of Effective Dose Equivalent of Indoor 222Rn Daughters in Inchass

    International Nuclear Information System (INIS)

    Ali, E.M.; Taha, T.M.; Gomaa, M.A.; El-Hussein, A.M.; Ahmad, A.A.

    2000-01-01

    The dominant component of natural radiation dose for the general population comes from the radon gas 222 Rn and its short-lived decay products, Ra A ( 214 Po), Ra B ( 214 Pb), Ra C ( 214 Bi), Ra C( 214 Po) in the breathing air. The objective of the present work is to assess the affective dose equivalent of the inhalation exposure of indoor 222 Rn for occupational workers. Average indon concentrations (Bqm -3 ) were monitored in several departments in Nuclear Research Center by radon monitor. We have calculated the lung dose equivalent and the effective dose equivalent for the Egyptian workers due to inhalation exposure of an equilibrium equivalent concentrations of radon daughters which varies from 0.27 to 2.5 mSvy -1 and 0.016 to 0.152mSvy -1 respectively. The annual effective doses obtained are within the accepted range of ICRP recommendations

  8. A study on assessment of bone mass from aluminum-equivalent image by digital imaging system

    International Nuclear Information System (INIS)

    Kim, Jin Soo; Kim, Jae Duck; Choi, Eui Hwan

    1997-01-01

    The purpose of this study was to evaluated the method for quantitative assessment of bone mass from aluminum-equivalent value of hydroxyapatite by using digital imaging system consisted of Power Macintosh 7200/120, 15-inch color monitor, and GT-9000 scanner with transparency unit. After aluminum-equivalent image made from correlation between aluminum thickness and grey scale, the accuracy of conversion to mass from aluminum-equivalent value was evaluated. Measured bone mass was compared with converted bone mass from aluminum-equivalent value of hydroxyapatite block by correlation formula between aluminum-equivalent value of hydroxy apatite block and hydroxyapatite mass. The results of this study were as follows : 1. Correlation between aluminum thickness and grey level for obtaining aluminum-equivalent image was high positively associated (r2=0.99). Converted masses from aluminum-equivalent value were very similar to measured masses. There was, statistically, no significant difference (P<0.05) between them. 2. Correlation between hydroxyapatite aluminum-equivalent and hydroxyapatite mass was shown to linear relation (r2 =0.95). 3. Converted masses from aluminum-equivalent value of 3 dry mandible segments were similar to measured masses. The difference between the exposure directions was not significantly different (P<0.05).

  9. Victor Brauner. Atrapulsion, peinture à la caséine sur toile présentant un important réseau de craquelures en cuvette

    OpenAIRE

    Pingeot, Cristina Cojocaru

    2014-01-01

    Atrapulsion est une peinture à la caséine sur toile de Victor Brauner (datée de 1938). L’altération majeure est constituée par la présence d’un réseau de craquelures généralisé, avec écailles en cuvette et en soulèvement. L’artiste a utilisé pour cette peinture des matières inadaptées à la peinture sur toile. L’œuvre a reçu un traitement de refixage avec une résine synthétique qui a laissé des résidus brillants en surface. L’élaboration du diagnostic a nécessité la réalisation d’essais de mod...

  10. Fibrinogen, homocyst(e)ine, and C-reactive protein concentrations relative to sex and socioeconomic status in British young people.

    Science.gov (United States)

    Thomas, Non-Eleri; Cooper, Stephen-Mark; Williams, Simon R P; Baker, Julien S; Davies, Bruce

    2005-01-01

    This study assesses the prevalence of recently identified coronary heart disease (CHD) risk factors in young people of differing socioeconomic status (SES). From November 2001 through March 2002, 100 boys and 108 girls, of age 12.9 +/- 0.3 years, selected from differing SES were assessed for CHD risk factors. Measurements included fibrinogen (Fg), homocyst(e)ine (Hcy), and C-reactive protein (CRP). Fibrinogen was significantly greater among boys from a higher SES compared with those from a low SES (P < or = 0.05). Differences according to sex (P < or = 0.05) were identified for Fg and CRP. The data indicate the prevalence of recently identified CHD risk factors in this cohort of British schoolchildren. For the purpose of this article, the phrase "young people" embraces both children and adolescents. Copyright 2005 Wiley-Liss, Inc

  11. Determination of equivalent breast phantoms for different age groups of Taiwanese women: An experimental approach

    International Nuclear Information System (INIS)

    Dong, Shang-Lung; Chu, Tieh-Chi; Lin, Yung-Chien; Lan, Gong-Yau; Yeh, Yu-Hsiu; Chen, Sharon; Chuang, Keh-Shih

    2011-01-01

    Purpose: Polymethylmethacrylate (PMMA) slab is one of the mostly used phantoms for studying breast dosimetry in mammography. The purpose of this study was to evaluate the equivalence between exposure factors acquired from PMMA slabs and patient cases of different age groups of Taiwanese women in mammography. Methods: This study included 3910 craniocaudal screen/film mammograms on Taiwanese women acquired on one mammographic unit. The tube loading, compressed breast thickness (CBT), compression force, tube voltage, and target/filter combination for each mammogram were collected for all patients. The glandularity and the equivalent thickness of PMMA were determined for each breast using the exposure factors of the breast in combination with experimental measurements from breast-tissue-equivalent attenuation slabs. Equivalent thicknesses of PMMA to the breasts of Taiwanese women were then estimated. Results: The average ± standard deviation CBT and breast glandularity in this study were 4.2 ± 1.0 cm and 54% ± 23%, respectively. The average equivalent PMMA thickness was 4.0 ± 0.7 cm. PMMA slabs producing equivalent exposure factors as in the breasts of Taiwanese women were determined for the age groups 30-49 yr and 50-69 yr. For the 4-cm PMMA slab, the CBT and glandularity values of the equivalent breast were 4.1 cm and 65%, respectively, for the age group 30-49 yr and 4.4 cm and 44%, respectively, for the age group 50-69 yr. Conclusions: The average thickness of PMMA slabs producing the same exposure factors as observed in a large group of Taiwanese women is less than that reported for American women. The results from this study can provide useful information for determining a suitable thickness of PMMA for mammographic dose survey in Taiwan. The equivalence of PMMA slabs and the breasts of Taiwanese women is provided to allow average glandular dose assessment in clinical practice.

  12. Determination of equivalent breast phantoms for different age groups of Taiwanese women: An experimental approach

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Shang-Lung; Chu, Tieh-Chi; Lin, Yung-Chien; Lan, Gong-Yau; Yeh, Yu-Hsiu; Chen, Sharon; Chuang, Keh-Shih [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, 101 Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan (China); Department of Radiology, Cheng Hsin General Hospital, 45 Cheng Hsin Street, Pai-Tou District, Taipei 11220, Taiwan (China); Department of Medical Imaging and Radiological Sciences, Kaohsiung Medical University, 100 Shih-Chuan 1st Road, Kaohsiung 80708, Taiwan (China); Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, 101 Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan (China)

    2011-07-15

    Purpose: Polymethylmethacrylate (PMMA) slab is one of the mostly used phantoms for studying breast dosimetry in mammography. The purpose of this study was to evaluate the equivalence between exposure factors acquired from PMMA slabs and patient cases of different age groups of Taiwanese women in mammography. Methods: This study included 3910 craniocaudal screen/film mammograms on Taiwanese women acquired on one mammographic unit. The tube loading, compressed breast thickness (CBT), compression force, tube voltage, and target/filter combination for each mammogram were collected for all patients. The glandularity and the equivalent thickness of PMMA were determined for each breast using the exposure factors of the breast in combination with experimental measurements from breast-tissue-equivalent attenuation slabs. Equivalent thicknesses of PMMA to the breasts of Taiwanese women were then estimated. Results: The average {+-} standard deviation CBT and breast glandularity in this study were 4.2 {+-} 1.0 cm and 54% {+-} 23%, respectively. The average equivalent PMMA thickness was 4.0 {+-} 0.7 cm. PMMA slabs producing equivalent exposure factors as in the breasts of Taiwanese women were determined for the age groups 30-49 yr and 50-69 yr. For the 4-cm PMMA slab, the CBT and glandularity values of the equivalent breast were 4.1 cm and 65%, respectively, for the age group 30-49 yr and 4.4 cm and 44%, respectively, for the age group 50-69 yr. Conclusions: The average thickness of PMMA slabs producing the same exposure factors as observed in a large group of Taiwanese women is less than that reported for American women. The results from this study can provide useful information for determining a suitable thickness of PMMA for mammographic dose survey in Taiwan. The equivalence of PMMA slabs and the breasts of Taiwanese women is provided to allow average glandular dose assessment in clinical practice.

  13. 78 FR 67360 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of Five New Equivalent Methods

    Science.gov (United States)

    2013-11-12

    ... Methods: Designation of Five New Equivalent Methods AGENCY: Office of Research and Development; Environmental Protection Agency (EPA). ACTION: Notice of the designation of five new equivalent methods for...) has designated, in accordance with 40 CFR Part 53, five new equivalent methods, one for measuring...

  14. 77 FR 60985 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of Three New Equivalent Methods

    Science.gov (United States)

    2012-10-05

    ... Methods: Designation of Three New Equivalent Methods AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of three new equivalent methods for monitoring ambient air quality. SUMMARY... equivalent methods, one for measuring concentrations of PM 2.5 , one for measuring concentrations of PM 10...

  15. Efficiency of metabolizable energy utilization for maintenance and gain and evaluation of Small Ruminant Nutrition System model in Santa Ines sheep

    Directory of Open Access Journals (Sweden)

    José Gilson Louzada Regadas Filho

    2011-11-01

    Full Text Available This study was carried out to estimate efficiencies of the utilization of metabolizable energy for maintenance (k m and weight gain (k g and to evaluate the Small Ruminant Nutrition System (SRNS model in predicting dry matter intake and average daily gain of growing Santa Ines sheep. Twenty-four non-castrated Santa Ines sheep, at 50 days of age and with average body weight of 13.00 ± 0.56 kg, respectively, were used. After a 10-day adaptation period, four animals were slaughtered to be used as reference for estimating initial empty body weight and body composition of the other animals. The remaining animals were distributed in a random block design, with the treatments consisting of diets containing different levels of metabolizable energy (2.08, 2.28, 2.47 and 2.69 Mcal/kg of DM, with five replicates. The metabolizable energy use efficiencies for maintenance and for weight gain were calculated from the relationship between the dietary net energy for maintenance and gain and ME concentration in the diets. Evaluation of the SRNS model was performed by adjustment of simple linear regression model between the predicted (independent variable and observed (dependent variable values. The estimated energy use efficiency for maintenance (k m was 0.70; and for gain weight (kg it showed to be inversely proportional to the increase of metabolizable energy concentration in the diet. The dry matter intake predicted by the SRNS model did not statistically differ from that observed, but the model overestimated the average daily gain by 5.18%. Those results can contribute to the construction of a database, which could be condensed into several others in a predictive model of performance and feed planning for sheep reared in Brazil.

  16. Analytical and numerical construction of equivalent cables.

    Science.gov (United States)

    Lindsay, K A; Rosenberg, J R; Tucker, G

    2003-08-01

    The mathematical complexity experienced when applying cable theory to arbitrarily branched dendrites has lead to the development of a simple representation of any branched dendrite called the equivalent cable. The equivalent cable is an unbranched model of a dendrite and a one-to-one mapping of potentials and currents on the branched model to those on the unbranched model, and vice versa. The piecewise uniform cable, with a symmetrised tri-diagonal system matrix, is shown to represent the canonical form for an equivalent cable. Through a novel application of the Laplace transform it is demonstrated that an arbitrary branched model of a dendrite can be transformed to the canonical form of an equivalent cable. The characteristic properties of the equivalent cable are extracted from the matrix for the transformed branched model. The one-to-one mapping follows automatically from the construction of the equivalent cable. The equivalent cable is used to provide a new procedure for characterising the location of synaptic contacts on spinal interneurons.

  17. Change of annual collective dose equivalent of radiation workers at KURRI

    International Nuclear Information System (INIS)

    Okamoto, Kenichi

    1994-01-01

    The change of exposure dose equivalent of radiation workers at KURRI (Kyoto University Research Reactor Institute) in the past 30 years is reported together with the operational accomplishments. The reactor achieved criticality on June 24, 1964 and reached the normal power of 1000 kW on August 17 of the same year, and the normal power was elevated to 5000 kW on July 16, 1968 until today. The change of the annual effective dose equivalent, the collective dose equivalent, the average annual dose equivalent and the maximum dose equivalent are indicated in the table and the figure. The chronological table on the activities of the reactor is added. (T.H.)

  18. Benefits of the effective dose equivalent concept at a medical center

    International Nuclear Information System (INIS)

    Vetter, R.J.; Classic, K.L.

    1991-01-01

    A primary objective of the recommendations of the International Committee on Radiological Protection Publication 26 is to insure that no source of radiation exposure is unjustified in relation to its benefits. This objective is consistent with goals of the Radiation Safety Committee and Institutional Review Board at medical centers where research may involve radiation exposure of human subjects. The effective dose equivalent concept facilitates evaluation of risk by those who have little or no knowledge of quantities or biological effects of radiation. This paper presents effective dose equivalent data used by radiation workers and those who evaluate human research protocols as these data relate to personal dosimeter reading, entrance skin exposure, and target organ dose. The benefits of using effective dose equivalent to evaluate risk of medical radiation environments and research protocols are also described

  19. Geometry of the local equivalence of states

    Energy Technology Data Exchange (ETDEWEB)

    Sawicki, A; Kus, M, E-mail: assawi@cft.edu.pl, E-mail: marek.kus@cft.edu.pl [Center for Theoretical Physics, Polish Academy of Sciences, Al Lotnikow 32/46, 02-668 Warszawa (Poland)

    2011-12-09

    We present a description of locally equivalent states in terms of symplectic geometry. Using the moment map between local orbits in the space of states and coadjoint orbits of the local unitary group, we reduce the problem of local unitary equivalence to an easy part consisting of identifying the proper coadjoint orbit and a harder problem of the geometry of fibers of the moment map. We give a detailed analysis of the properties of orbits of 'equally entangled states'. In particular, we show connections between certain symplectic properties of orbits such as their isotropy and coisotropy with effective criteria of local unitary equivalence. (paper)

  20. Measurement Of Lead Equivalent Thickness For Irradiation Room: An Analysis

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Azuhar Ripin; Husaini Salleh; Mohd Khairusalih Mohd Zin; Muhammad Jamal Muhd Isa; Mohd Faizal Abdul Rahman

    2014-01-01

    The Malaysian Ministry of Health (MOH) has established that the irradiation room must have a sufficient thickness of shielding to ensure that requirements for the purpose of radiation protection of patients, employees and the public are met. This paper presents a technique using americium-241 source to test and verify the integrity of the shielding thickness in term of lead equivalent for irradiation room at health clinics own by MOH. Results of measurement of 8 irradiation rooms conducted in 2014 were analyzed for this presentation. Technical comparison of the attenuation of gamma rays from Am-241 source through the walls of the irradiation room and pieces of lead were used to assess the lead equivalent thickness of the walls. Results showed that almost all the irradiation rooms tested meet the requirements of the Ministry of Health and is suitable for the installation of the intended diagnostic X-ray apparatus. Some specific positions such as door knobs and locks, electrical plug sockets were identified with potential to not met the required lead equivalent thickness hence may contribute to higher radiation exposure to workers and the public. (author)

  1. Application of A150-plastic equivalent gases in microdosimetric measurements

    International Nuclear Information System (INIS)

    DeLuca, P.M. Jr.; Higgins, P.D.; Pearson, D.W.; Schell, M.; Attix, F.H.

    1981-01-01

    Neutron dosimetry measurements with ionization chambers, for the most part, employ tissue equivalent plastic-walled cavities (Shonka A150) filled with either air or a methane-base tissue-like gas. The atomic composition of TE-gas and A150 plastic are not matched and are quite dissimilar from muscle. Awschalom and Attix (1980) have partially resolved the problem by formulating a novel A150-plastic equivalent gas. This establishes a homogeneous wall-gas cavity dosimeter for neutron measurements and confines the necessary corrections to the applications of kerma ratios. In this report, we present measurements of applications of two A150-plastic equivalent gases in a low pressure spherical proportional counter. Gas gains and alpha-particle resolutions were determined. For these A150-mixtures as well as a methane-based TE-gas and an Ar-CO 2 mixture, we report measurements of event size distributions from exposure to a beam of 14.8 MeV neutrons

  2. Quantum equivalence principle without mass superselection

    International Nuclear Information System (INIS)

    Hernandez-Coronado, H.; Okon, E.

    2013-01-01

    The standard argument for the validity of Einstein's equivalence principle in a non-relativistic quantum context involves the application of a mass superselection rule. The objective of this work is to show that, contrary to widespread opinion, the compatibility between the equivalence principle and quantum mechanics does not depend on the introduction of such a restriction. For this purpose, we develop a formalism based on the extended Galileo group, which allows for a consistent handling of superpositions of different masses, and show that, within such scheme, mass superpositions behave as they should in order to obey the equivalence principle. - Highlights: • We propose a formalism for consistently handling, within a non-relativistic quantum context, superpositions of states with different masses. • The formalism utilizes the extended Galileo group, in which mass is a generator. • The proposed formalism allows for the equivalence principle to be satisfied without the need of imposing a mass superselection rule

  3. On the equivalence of chaos control systems

    International Nuclear Information System (INIS)

    Wang Xiaofan

    2003-01-01

    For a given chaotic system, different control systems can be constructed depending on which parameter is tuned or where the external input is added. We prove that two different feedback control systems are qualitatively equivalent if they are feedback linearizable

  4. Equivalence relations and the reinforcement contingency.

    Science.gov (United States)

    Sidman, M

    2000-07-01

    Where do equivalence relations come from? One possible answer is that they arise directly from the reinforcement contingency. That is to say, a reinforcement contingency produces two types of outcome: (a) 2-, 3-, 4-, 5-, or n-term units of analysis that are known, respectively, as operant reinforcement, simple discrimination, conditional discrimination, second-order conditional discrimination, and so on; and (b) equivalence relations that consist of ordered pairs of all positive elements that participate in the contingency. This conception of the origin of equivalence relations leads to a number of new and verifiable ways of conceptualizing equivalence relations and, more generally, the stimulus control of operant behavior. The theory is also capable of experimental disproof.

  5. REFractions: The Representing Equivalent Fractions Game

    Science.gov (United States)

    Tucker, Stephen I.

    2014-01-01

    Stephen Tucker presents a fractions game that addresses a range of fraction concepts including equivalence and computation. The REFractions game also improves students' fluency with representing, comparing and adding fractions.

  6. ON THE EQUIVALENCE OF THE ABEL EQUATION

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    This article uses the reflecting function of Mironenko to study some complicated differential equations which are equivalent to the Abel equation. The results are applied to discuss the behavior of solutions of these complicated differential equations.

  7. interpratation: of equivalences and cultural untranslatability

    African Journals Online (AJOL)

    jgmweri

    translatability in cultural diversity in terms equivalences such as –Vocabulary or lexical ..... A KSL interpreter who does not understand this English idiom may literally interpret it .... Nida, E.A. (1958) Analysis of meaning and dictionary making.

  8. Equivalence Principle, Higgs Boson and Cosmology

    Directory of Open Access Journals (Sweden)

    Mauro Francaviglia

    2013-05-01

    Full Text Available We discuss here possible tests for Palatini f(R-theories together with their implications for different formulations of the Equivalence Principle. We shall show that Palatini f(R-theories obey the Weak Equivalence Principle and violate the Strong Equivalence Principle. The violations of the Strong Equivalence Principle vanish in vacuum (and purely electromagnetic solutions as well as on short time scales with respect to the age of the universe. However, we suggest that a framework based on Palatini f(R-theories is more general than standard General Relativity (GR and it sheds light on the interpretation of data and results in a way which is more model independent than standard GR itself.

  9. The gauge principle vs. the equivalence principle

    International Nuclear Information System (INIS)

    Gates, S.J. Jr.

    1984-01-01

    Within the context of field theory, it is argued that the role of the equivalence principle may be replaced by the principle of gauge invariance to provide a logical framework for theories of gravitation

  10. Dark matter and the equivalence principle

    Science.gov (United States)

    Frieman, Joshua A.; Gradwohl, Ben-Ami

    1993-01-01

    A survey is presented of the current understanding of dark matter invoked by astrophysical theory and cosmology. Einstein's equivalence principle asserts that local measurements cannot distinguish a system at rest in a gravitational field from one that is in uniform acceleration in empty space. Recent test-methods for the equivalence principle are presently discussed as bases for testing of dark matter scenarios involving the long-range forces between either baryonic or nonbaryonic dark matter and ordinary matter.

  11. S-equivalents lagrangians in generalized mechanics

    International Nuclear Information System (INIS)

    Negri, L.J.; Silva, Edna G. da.

    1985-01-01

    The problem of s-equivalent lagrangians is considered in the realm of generalized mechanics. Some results corresponding to the ordinary (non-generalized) mechanics are extended to the generalized case. A theorem for the reduction of the higher order lagrangian description to the usual order is found to be useful for the analysis of generalized mechanical systems and leads to a new class of equivalence between lagrangian functions. Some new perspectives are pointed out. (Author) [pt

  12. Effect of in vitro exposure to cadmium and copper on sea bass blood cells

    Directory of Open Access Journals (Sweden)

    Vincenzo Arizza

    2010-01-01

    Full Text Available Blood cells freshly collected from sea bass (Dicentrarchus labrax were exposed in vitro to different concentrations of cadmium (Cd and copper (Cu at 10-7 M, 10-5 M, 10-3 M, and exam- ined for neutral red retention capacity and for cell vitality with MTT assay. A relationship between heavy metal exposure and alteration in responses of blood cells in a dose-time-dependent was found. Our results showed that fish blood cells may constitute an interesting biological model for experimen- tal and applied toxicology, especially in the case of environmental pollution.

  13. The principle of equivalence reconsidered: assessing the relevance of the principle of equivalence in prison medicine.

    Science.gov (United States)

    Jotterand, Fabrice; Wangmo, Tenzin

    2014-01-01

    In this article we critically examine the principle of equivalence of care in prison medicine. First, we provide an overview of how the principle of equivalence is utilized in various national and international guidelines on health care provision to prisoners. Second, we outline some of the problems associated with its applications, and argue that the principle of equivalence should go beyond equivalence to access and include equivalence of outcomes. However, because of the particular context of the prison environment, third, we contend that the concept of "health" in equivalence of health outcomes needs conceptual clarity; otherwise, it fails to provide a threshold for healthy states among inmates. We accomplish this by examining common understandings of the concepts of health and disease. We conclude our article by showing why the conceptualization of diseases as clinical problems provides a helpful approach in the delivery of health care in prison.

  14. Equivalence of Szegedy's and coined quantum walks

    Science.gov (United States)

    Wong, Thomas G.

    2017-09-01

    Szegedy's quantum walk is a quantization of a classical random walk or Markov chain, where the walk occurs on the edges of the bipartite double cover of the original graph. To search, one can simply quantize a Markov chain with absorbing vertices. Recently, Santos proposed two alternative search algorithms that instead utilize the sign-flip oracle in Grover's algorithm rather than absorbing vertices. In this paper, we show that these two algorithms are exactly equivalent to two algorithms involving coined quantum walks, which are walks on the vertices of the original graph with an internal degree of freedom. The first scheme is equivalent to a coined quantum walk with one walk step per query of Grover's oracle, and the second is equivalent to a coined quantum walk with two walk steps per query of Grover's oracle. These equivalences lie outside the previously known equivalence of Szegedy's quantum walk with absorbing vertices and the coined quantum walk with the negative identity operator as the coin for marked vertices, whose precise relationships we also investigate.

  15. Quantum mechanics and the equivalence principle

    International Nuclear Information System (INIS)

    Davies, P C W

    2004-01-01

    A quantum particle moving in a gravitational field may penetrate the classically forbidden region of the gravitational potential. This raises the question of whether the time of flight of a quantum particle in a gravitational field might deviate systematically from that of a classical particle due to tunnelling delay, representing a violation of the weak equivalence principle. I investigate this using a model quantum clock to measure the time of flight of a quantum particle in a uniform gravitational field, and show that a violation of the equivalence principle does not occur when the measurement is made far from the turning point of the classical trajectory. The results are then confirmed using the so-called dwell time definition of quantum tunnelling. I conclude with some remarks about the strong equivalence principle in quantum mechanics

  16. Water equivalence of polymer gel dosimeters

    International Nuclear Information System (INIS)

    Sellakumar, P.; James Jebaseelan Samuel, E.; Supe, Sanjay S.

    2007-01-01

    To evaluate the water equivalence and radiation transport properties of polymer gel dosimeters over the wide range of photon and electron energies 14 different types of polymer gels were considered. Their water equivalence was evaluated in terms of effective atomic number (Z eff ), electron density (ρ e ), photon mass attenuation coefficient (μ/ρ), photon mass energy absorption coefficient (μ en /ρ) and total stopping power (S/ρ) tot of electrons using the XCOM and the ESTAR database. The study showed that the effective atomic number of polymer gels were very close ( en /ρ for all polymer gels were in close agreement ( tot of electrons in polymer gel dosimeters were within 1% agreement with that of water. From the study we conclude that at lower energy (<80keV) the polymer gel dosimeters cannot be considered water equivalent and study has to be carried out before using the polymer gel for clinical application

  17. Using frequency equivalency in stability calculations

    Energy Technology Data Exchange (ETDEWEB)

    Gruzdev, I.A.; Temirbulatov, R.A.; Tereshko, L.A.

    1981-01-01

    A methodology for calculating oscillatory instability that involves using frequency equivalency is employed in carrying out the following proceedures: dividing an electric power system into subgroups; determining the adjustments to the automatic excitation control in each subsystem; simplifying the mathematical definition of the separate subsystems by using frequency equivalency; gradually re-tuning the automatic excitation control in the separate subsystems to account for neighboring subsystems by using their equivalent frequency characteristics. The methodology is to be used with a computer program to determine the gain in the stabilization channels of the automatic excitation control unit in which static stability of the entire aggregate of normal and post-breakdown conditions acceptable damping of transient processes are provided. The possibility of reducing the equation series to apply to chosen regions of the existing range of frequencies is demonstrated. The use of the methodology is illustrated in a sample study on stability in a Siberian unified power system.

  18. The equivalence problem for LL- and LR-regular grammars

    NARCIS (Netherlands)

    Nijholt, Antinus; Gecsec, F.

    It will be shown that the equivalence problem for LL-regular grammars is decidable. Apart from extending the known result for LL(k) grammar equivalence to LLregular grammar equivalence, we obtain an alternative proof of the decidability of LL(k) equivalence. The equivalence prob]em for LL-regular

  19. Fiscal adjustments in Europe and Ricardian equivalence

    Directory of Open Access Journals (Sweden)

    V. DE BONIS

    1998-09-01

    Full Text Available According to the ‘Ricardian’ equivalence hypothesis, consumption is dependent on permanent disposable income and current deficits are equivalent to future tax payments. This hypothesis is tested on 14 European countries in the 1990s. The relationships between private sector savings and general government deficit, and the GDP growth rate and the unemployment rate are determined. The results show the change in consumers' behaviour with respect to government deficit, and that expectations of an increase in future wealth are no longer associated with a decrease in deficit.

  20. Equivalent circuit analysis of terahertz metamaterial filters

    KAUST Repository

    Zhang, Xueqian

    2011-01-01

    An equivalent circuit model for the analysis and design of terahertz (THz) metamaterial filters is presented. The proposed model, derived based on LMC equivalent circuits, takes into account the detailed geometrical parameters and the presence of a dielectric substrate with the existing analytic expressions for self-inductance, mutual inductance, and capacitance. The model is in good agreement with the experimental measurements and full-wave simulations. Exploiting the circuit model has made it possible to predict accurately the resonance frequency of the proposed structures and thus, quick and accurate process of designing THz device from artificial metamaterials is offered. ©2011 Chinese Optics Letters.

  1. Topological equivalence of nonlinear autonomous dynamical systems

    International Nuclear Information System (INIS)

    Nguyen Huynh Phan; Tran Van Nhung

    1995-12-01

    We show in this paper that the autonomous nonlinear dynamical system Σ(A,B,F): x' = Ax+Bu+F(x) is topologically equivalent to the linear dynamical system Σ(A,B,O): x' = Ax+Bu if the projection of A on the complement in R n of the controllable vectorial subspace is hyperbolic and if lipschitz constant of F is sufficiently small ( * ) and F(x) = 0 when parallel x parallel is sufficiently large ( ** ). In particular, if Σ(A,B,O) is controllable, it is topologically equivalent to Σ(A,B,F) when it is only that F satisfy ( ** ). (author). 18 refs

  2. A neutron dose equivalent meter at CAEP

    International Nuclear Information System (INIS)

    Tian Shihai; Lu Yan; Wang Heyi; Yuan Yonggang; Chen Xu

    2012-01-01

    The measurement of neutron dose equivalent has been a widespread need in industry and research. In this paper, aimed at improving the accuracy of neutron dose equivalent meter: a neutron dose counter is simulated with MCNP5, and the energy response curve is optimized. The results show that the energy response factor is from 0.2 to 1.8 for neutrons in the energy range of 2.53×10 -8 MeV to 10 MeV Compared with other related meters, it turns that the design of this meter is right. (authors)

  3. Measurements of the personal dose equivalent

    International Nuclear Information System (INIS)

    Scarlat, F.; Scarisoreanu, A.; Badita, E.; Oane, M.; Mitru, E.

    2008-01-01

    Full text: The paper presents the results of measurements related to the personal dose equivalent in the rooms adjacent to NILPRP 7 MeV linear accelerator, by means of the secondary standard chamber T34035 Hp(10). The chamber was calibrated by PTB at S- 137 Cs (E av = 661.6 keV, T 1/2 11050 days) and has N H = 3.17x10 6 Sv/C calibration factor for the personal dose equivalent, Hp(10), at a depth of 10 mm in climatic reference conditions. The measurements were made for the two operation mode of the 7 MeV linac: electrons and bremsstrahlung

  4. Determination of equivalent copper thickness of patient equivalent phantoms in terms of attenuation, used in radiology

    International Nuclear Information System (INIS)

    Jansen, J.Th.M.; Suliman, I.I.; Zoetelief, J.

    2002-01-01

    aluminium filtration. The Monte Carlo N-Particle transport code (MCNP) is used to calculate the attenuation in the different geometries with the PMMA or copper or no filters applied. In all these cases the detector is placed at 1.0005 m distance from the focus on the central beam axis, with all filters between the detector and the focus. No anti-scatter grid is used in these calculations. With different thickness of the PMMA phantom and appropriate tube voltage the attenuation is calculated. The copper filter thickness is adjusted to get the same attenuation as obtained with the relevant PMMA phantoms. This match is made for the PMMA-phantom in front of the image intensifier and the copper filter in front of the image intensifier or attached to the X-ray tube diaphragm. In addition a match is made with both the PMMA and copper filter attached to the X-ray tube diaphragm. The image intensifier is simulated by a CsI plate 0.5 mm thickness, placed at 1.001 m from the focus. The front filters are placed 0.15 m from the focus and the back filters are ending 1.00 m from the focus. The results will be presented as the copper equivalent filter thickness for the PMMA phantom thicknesses mentioned above for different tube voltages and both beam geometries. The situation with both the PMMA phantom and copper filter in the back position is used to estimate the patient entrance surface dose rates. The equivalent copper filter calculation is based on the detector behind the attenuators to simulate the performance of an Automatic Exposure Controller (AEC). In addition detectors are placed 0.5 mm in front of the PMMA phantom and the copper filter and corrected by the inverse square law to a focus detector distance of 0.50 m. Comparison between both situations is made to estimate the uncertainty in the ionisation chamber measurement. The equivalent copper filter is based on equal attenuation therefore the beam quality will, in general, be different. In order to characterise these

  5. EFFDOS - a FORTRAN-77-code for the calculation of the effective dose equivalent

    International Nuclear Information System (INIS)

    Baer, M.; Honcu, S.; Huebschmann, W.

    1984-01-01

    The FORTRAN-77-code EFFDOS calculates the effective dose equivalent according to ICRP 26 due to the longterm emission of radionuclides into the atmosphere for the following exposure pathways: inhalation, ingestion, γ-ground irradiation (γ-irradiation by radionuclides deposited on the ground) and β- or γ-submersion (irradiation by the passing radioactive cloud). For calculating the effective dose equivalent at a single spot it is necessary to put in the diffusion factor and - if need be - the washout factor; otherwise EFFDOS calculates the input data for the computer codes ISOLA III and WOLGA-1, which then are enabled to compute the atmospheric diffusion, ground deposition and local dose equivalent distribution for the requested exposure pathway. Atmospheric diffusion, deposition and radionuclide transfer are calculated according to the ''Allgemeine Berechnungsgrundlage ....'' recommended by the German Fed. Ministry of Interior. A sample calculated is added. (orig.) [de

  6. Lead Equivalent Thickness Measurement for Mixed Compositions of Barium Plaster Block

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Muhammad Jamal Muhammad Isa; Nur Shahriza Zainuddin; Mohd Khairusalih Md Zin; Shahrul Azlan Azizan

    2016-01-01

    Measurement of lead equivalent thickness for ionizing radiation exposure room wall shall be performed as stated in Malaysian Standard MS 838. A few numbers of sample blocks with different mixture of barium plaster compositions based and varies certain thickness as a shielding material for exposure room wall belong to a local company were tested by using Cs-137, Co-60 and Am-241 with different activities . Radiations passed through the samples were detected with calibrated survey meter. The distance between radiation source and the detector is about 40 cm. Lead uniformity test on the samples was also determined at three labeled points on the samples. Lead equivalent thicknesses for the samples were evaluated based on a calibration graph that was plotted with lead sheets and with the radiation sources. Results shown that lead equivalent thickness for the samples with same actual physical thickness represent different values for different sources. (author)

  7. Bone marrow equivalent prompt dose from two common fallout scenarios

    International Nuclear Information System (INIS)

    Morris, M.D.; Jones, T.D.; Young, R.W.

    1994-01-01

    A cell-kinetics model for radiation-induced myelopoiesis has been derived for mice, rats, dogs, sheep, swine, and burros. The model was extended to humans after extensive comparisons with molecular and cellular data from biological experiments and an assortment of predictive/validation tests on animal mortality, cell survival, and cellular repopulation following irradiations. One advantage of the model is that any complex pattern of protracted irradiation can be equated to its equivalent prompt dose. Severity of biological response depends upon target-organ dose, dose rate, and dose fractionation. Epidemiological and animal data are best suited for exposures given in brief periods of time. To use those data to assess risk from protracted human exposures, it is obligatory to model molecular repair and compensatory proliferation in terms of prompt dose. Although the model is somewhat complex both mathematically and biologically, this note describes simple numerical approximations for two common exposure scenarios. Both approximations are easily evaluated on a simple pocket calculator by a health physicist or emergency management officer. 12 refs., 5 figs

  8. Detection of ultraviolet radiation using tissue equivalent radiochromic gel materials

    International Nuclear Information System (INIS)

    Bero, M A; Abukassem, I

    2009-01-01

    Ferrous Xylenol-orange Gelatin gel (FXG) is known to be sensitive to ionising radiation such as γ and X-rays. The effect of ionising radiation is to produce an increase in the absorption over a wide region of the visible spectrum, which is proportional to the absorbed dose. This study demonstrates that FXG gel is sensitive to ultraviolet radiation and therefore it could functions as UV detector. Short exposure to UV radiation produces linear increase in absorption measured at 550nm, however high doses of UV cause the ion indicator colour to fad away in a manner proportional to the incident UV energy. Light absorbance increase at the rate of 1.1% per minute of irradiation was monitored. The exposure level at which the detector has linear response is comparable to the natural summer UV radiation. Evaluating the UV ability to pass through tissue equivalent gel materials shows that most of the UV gets absorbed in the first 5mm of the gel materials, which demonstrate the damaging effects of this radiation type on human skin and eyes. It was concluded that FXG gel dosimeter has the potential to offer a simple, passive ultraviolet radiation detector with sensitivity suitable to measure and visualises the natural sunlight UV exposure directly by watching the materials colour changes.

  9. Detection of ultraviolet radiation using tissue equivalent radiochromic gel materials

    Science.gov (United States)

    Bero, M. A.; Abukassem, I.

    2009-05-01

    Ferrous Xylenol-orange Gelatin gel (FXG) is known to be sensitive to ionising radiation such as γ and X-rays. The effect of ionising radiation is to produce an increase in the absorption over a wide region of the visible spectrum, which is proportional to the absorbed dose. This study demonstrates that FXG gel is sensitive to ultraviolet radiation and therefore it could functions as UV detector. Short exposure to UV radiation produces linear increase in absorption measured at 550nm, however high doses of UV cause the ion indicator colour to fad away in a manner proportional to the incident UV energy. Light absorbance increase at the rate of 1.1% per minute of irradiation was monitored. The exposure level at which the detector has linear response is comparable to the natural summer UV radiation. Evaluating the UV ability to pass through tissue equivalent gel materials shows that most of the UV gets absorbed in the first 5mm of the gel materials, which demonstrate the damaging effects of this radiation type on human skin and eyes. It was concluded that FXG gel dosimeter has the potential to offer a simple, passive ultraviolet radiation detector with sensitivity suitable to measure and visualises the natural sunlight UV exposure directly by watching the materials colour changes.

  10. 77 FR 32632 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of Three New Equivalent Methods

    Science.gov (United States)

    2012-06-01

    ... Methods: Designation of Three New Equivalent Methods AGENCY: Environmental Protection Agency. ACTION... accordance with 40 CFR Part 53, three new equivalent methods: One for measuring concentrations of nitrogen... INFORMATION: In accordance with regulations at 40 CFR Part 53, the EPA evaluates various methods for...

  11. Confluence Modulo Equivalence in Constraint Handling Rules

    DEFF Research Database (Denmark)

    Christiansen, Henning; Kirkeby, Maja Hanne

    2015-01-01

    Previous results on confluence for Constraint Handling Rules, CHR, are generalized to take into account user-defined state equivalence relations. This allows a much larger class of programs to enjoy the advantages of confluence, which include various optimization techniques and simplified...

  12. Free Fall and the Equivalence Principle Revisited

    Science.gov (United States)

    Pendrill, Ann-Marie

    2017-01-01

    Free fall is commonly discussed as an example of the equivalence principle, in the context of a homogeneous gravitational field, which is a reasonable approximation for small test masses falling moderate distances. Newton's law of gravity provides a generalisation to larger distances, and also brings in an inhomogeneity in the gravitational field.…

  13. Estimation of Toxicity Equivalent Concentration (TEQ) of ...

    African Journals Online (AJOL)

    Estimation of Toxicity Equivalent Concentration (TEQ) of carcinogenic polycyclic aromatic hydrocarbons in soils from Idu Ekpeye playground and University of Port ... Effective soil remediation and detoxification method like Dispersion by chemical reaction technology should be deployed to clean-up sites to avoid soil toxicity ...

  14. Chemical equivalence assessment of three brands of ...

    African Journals Online (AJOL)

    Assay for content of active ingredients is a critical test of drug quality; failure to meet up the standard for content of active ingredients will result to sub therapeutic quantities. Three brands (A, B and C) of carbamazepine were assayed to determine their chemical equivalence as well as their anticonvulsant activities. This was ...

  15. On Behavioral Equivalence of Rational Representations

    NARCIS (Netherlands)

    Trentelman, Harry L.; Willems, JC; Hara, S; Ohta, Y; Fujioka, H

    2010-01-01

    This article deals with the equivalence of representations of behaviors of linear differential systems In general. the behavior of a given linear differential system has many different representations. In this paper we restrict ourselves to kernel representations and image representations Two kernel

  16. Visual Equivalence and Amodal Completion in Cuttlefish.

    Science.gov (United States)

    Lin, I-Rong; Chiao, Chuan-Chin

    2017-01-01

    Modern cephalopods are notably the most intelligent invertebrates and this is accompanied by keen vision. Despite extensive studies investigating the visual systems of cephalopods, little is known about their visual perception and object recognition. In the present study, we investigated the visual processing of the cuttlefish Sepia pharaonis , including visual equivalence and amodal completion. Cuttlefish were trained to discriminate images of shrimp and fish using the operant conditioning paradigm. After cuttlefish reached the learning criteria, a series of discrimination tasks were conducted. In the visual equivalence experiment, several transformed versions of the training images, such as images reduced in size, images reduced in contrast, sketches of the images, the contours of the images, and silhouettes of the images, were used. In the amodal completion experiment, partially occluded views of the original images were used. The results showed that cuttlefish were able to treat the training images of reduced size and sketches as the visual equivalence. Cuttlefish were also capable of recognizing partially occluded versions of the training image. Furthermore, individual differences in performance suggest that some cuttlefish may be able to recognize objects when visual information was partly removed. These findings support the hypothesis that the visual perception of cuttlefish involves both visual equivalence and amodal completion. The results from this research also provide insights into the visual processing mechanisms used by cephalopods.

  17. Possibility and necessity measures and integral equivalence

    Czech Academy of Sciences Publication Activity Database

    Chen, T.; Mesiar, Radko; Li, J.; Stupňanová, A.

    2017-01-01

    Roč. 86, č. 1 (2017), s. 62-72 ISSN 0888-613X Institutional support: RVO:67985556 Keywords : Integral equivalence * Necessity measure * Possibility measure * Survival function * Universal integral Subject RIV: BA - General Mathematics OBOR OECD: Statistics and probability Impact factor: 2.845, year: 2016 http://library.utia.cas.cz/separaty/2017/E/mesiar-0477092.pdf

  18. Fuel Cell Equivalent Electric Circuit Parameter Mapping

    DEFF Research Database (Denmark)

    Jeppesen, Christian; Zhou, Fan; Andreasen, Søren Juhl

    In this work a simple model for a fuel cell is investigated for diagnostic purpose. The fuel cell is characterized, with respect to the electrical impedance of the fuel cell at non-faulty conditions and under variations in load current. Based on this the equivalent electrical circuit parameters can...

  19. Weak equivalence classes of complex vector bundles

    Czech Academy of Sciences Publication Activity Database

    Le, Hong-Van

    LXXVII, č. 1 (2008), s. 23-30 ISSN 0862-9544 R&D Projects: GA AV ČR IAA100190701 Institutional research plan: CEZ:AV0Z10190503 Keywords : chern classes * complex Grassmannians weak equivalence Subject RIV: BA - General Mathematics

  20. Violation of Equivalence Principle and Solar Neutrinos

    International Nuclear Information System (INIS)

    Gago, A.M.; Nunokawa, H.; Zukanovich Funchal, R.

    2001-01-01

    We have updated the analysis for the solution to the solar neutrino problem by the long-wavelength neutrino oscillations induced by a tiny breakdown of the weak equivalence principle of general relativity, and obtained a very good fit to all the solar neutrino data

  1. Bilingual Dictionaries and Communicative Equivalence for a ...

    African Journals Online (AJOL)

    This implies that a bilingual dictionary becomes a poly functional instrument, presenting more information than just translation equivalents. ... With the emphasis on the user perspective, metalexicographical criteria are used to investigate problems regarding the access structure and the addressing procedures in Afrikaans ...

  2. Equivalent operator preconditioning for elliptic problems

    Czech Academy of Sciences Publication Activity Database

    Axelsson, Owe; Karátson, J.

    2009-01-01

    Roč. 50, č. 3 (2009), s. 297-380 ISSN 1017-1398 Institutional research plan: CEZ:AV0Z30860518 Keywords : Elliptic problem * Conjugate gradient method * preconditioning * equivalent operators * compact operators Subject RIV: BA - General Mathematics Impact factor: 0.716, year: 2009 http://en.scientificcommons.org/42514649

  3. Superstring field theory equivalence: Ramond sector

    International Nuclear Information System (INIS)

    Kroyter, Michael

    2009-01-01

    We prove that the finite gauge transformation of the Ramond sector of the modified cubic superstring field theory is ill-defined due to collisions of picture changing operators. Despite this problem we study to what extent could a bijective classical correspondence between this theory and the (presumably consistent) non-polynomial theory exist. We find that the classical equivalence between these two theories can almost be extended to the Ramond sector: We construct mappings between the string fields (NS and Ramond, including Chan-Paton factors and the various GSO sectors) of the two theories that send solutions to solutions in a way that respects the linearized gauge symmetries in both sides and keeps the action of the solutions invariant. The perturbative spectrum around equivalent solutions is also isomorphic. The problem with the cubic theory implies that the correspondence of the linearized gauge symmetries cannot be extended to a correspondence of the finite gauge symmetries. Hence, our equivalence is only formal, since it relates a consistent theory to an inconsistent one. Nonetheless, we believe that the fact that the equivalence formally works suggests that a consistent modification of the cubic theory exists. We construct a theory that can be considered as a first step towards a consistent RNS cubic theory.

  4. Equivalence Scales for the Former West Germany

    NARCIS (Netherlands)

    Charlier, E.

    1997-01-01

    Equivalence scales provide answers to questions like how much a household with four children needs to spend compared to a household with two children or how much a childless couple needs to spend compared to a single person household to attain the same welfare level. These are important questions

  5. Confluence Modulo Equivalence in Constraint Handling Rules

    DEFF Research Database (Denmark)

    Christiansen, Henning; Kirkeby, Maja Hanne

    2014-01-01

    Previous results on confluence for Constraint Handling Rules, CHR, are generalized to take into account user-defined state equivalence relations. This allows a much larger class of programs to enjoy the ad- vantages of confluence, which include various optimization techniques and simplified...

  6. Equivalence of rational representations of behaviors

    NARCIS (Netherlands)

    Gottimukkala, Sasanka; Fiaz, Shaik; Trentelman, H.L.

    This article deals with the equivalence of representations of behaviors of linear differential systems. In general, the behavior of a given linear differential system has many different representations. In this paper we restrict ourselves to kernel and image representations. Two kernel

  7. Equivalent physical models and formulation of equivalent source layer in high-resolution EEG imaging

    International Nuclear Information System (INIS)

    Yao Dezhong; He Bin

    2003-01-01

    In high-resolution EEG imaging, both equivalent dipole layer (EDL) and equivalent charge layer (ECL) assumed to be located just above the cortical surface have been proposed as high-resolution imaging modalities or as intermediate steps to estimate the epicortical potential. Presented here are the equivalent physical models of these two equivalent source layers (ESL) which show that the strength of EDL is proportional to the surface potential of the layer when the outside of the layer is filled with an insulator, and that the strength of ECL is the normal current of the layer when the outside is filled with a perfect conductor. Based on these equivalent physical models, closed solutions of ECL and EDL corresponding to a dipole enclosed by a spherical layer are given. These results provide the theoretical basis of ESL applications in high-resolution EEG mapping

  8. Equivalent physical models and formulation of equivalent source layer in high-resolution EEG imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yao Dezhong [School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu City, 610054, Sichuan Province (China); He Bin [The University of Illinois at Chicago, IL (United States)

    2003-11-07

    In high-resolution EEG imaging, both equivalent dipole layer (EDL) and equivalent charge layer (ECL) assumed to be located just above the cortical surface have been proposed as high-resolution imaging modalities or as intermediate steps to estimate the epicortical potential. Presented here are the equivalent physical models of these two equivalent source layers (ESL) which show that the strength of EDL is proportional to the surface potential of the layer when the outside of the layer is filled with an insulator, and that the strength of ECL is the normal current of the layer when the outside is filled with a perfect conductor. Based on these equivalent physical models, closed solutions of ECL and EDL corresponding to a dipole enclosed by a spherical layer are given. These results provide the theoretical basis of ESL applications in high-resolution EEG mapping.

  9. Tratamiento de la diabetes mellitus tipo 2 en el municipio de Güines, año 2002: Análisis con énfasis en la terapia medicamentosa Treatment of type 2 diabetes mellitus in Güines municipality in the year 2002: Drug therapy-based analysis

    Directory of Open Access Journals (Sweden)

    José Luis Valenciaga Rodríguez

    2003-08-01

    Full Text Available Se realizó una investigación de corte transversal con el objetivo de identificar las características del tratamiento en personas con diabetes mellitus tipo 2 pertenecientes al municipio de Güines, en el año 2002, específicamente en la utilización de compuestos orales normo o hipoglucemiantes e insulina. El universo lo constituyeron 3 017 diabéticos tipo 2 registrados en el municipio en el año 2001, y la muestra 328 de estos casos, seleccionados a través de diseño muestral complejo (estratificado en la primera etapa y por conglomerados en la segunda. Los datos obtenidos se procesaron estadísticamente, con el empleo del programa SPSS (versión 10. La media de edad de la muestra fue de 65, 2 años y de 12,8 de la fecha de diagnóstico. Un total de 161 personas (49,1 % se trataba con dieta solamente y 42 con insulina; de ellos todos empleaban insulina de acción intermedia y 3 (7,1 % la de acción rápida. El compuesto hipoglucemiante más utilizado fue la Glibenclamida, en 131 casos (85,5 %, y su dosis media diaria fue de 15 mg, mientras aproximadamente 1 de cada 10 casos empleaba medicina verde. Se concluye que existen deficiencias en el manejo terapéutico, específicamente en la forma de utilización de insulina, escasa disponibilidad de compuestos orales normo o hipoglucemiantes y alta frecuencia de tratamiento no farmacológico. Se recomienda reanalizar el cumplimiento del Programa Nacional de Diabetes Mellitus en el municipio de Güines, con énfasis en la capacitación del personal de salud en aspectos terapéuticos, así como incrementar la disponibilidad de compuestos orales normo o hipoglucemiantes, específicamente de Metformin, en el municipio.A cross-sectional study was made to identify the characteristics of treatment of persons with type 2 diabetes mellitus in Güines municipality during 2002, particularly the use of oral normo or hypoglicemic compounds and insulin. The universe was made up of 3 017 type 2 diabetics

  10. Homocyst(e)ine, folate, and vitamin B12 status in a cohort of Welsh young people aged 12-13 years old.

    Science.gov (United States)

    Thomas, N E; Cooper, S M; Baker, J S; Graham, M R; Davies, B

    2008-01-01

    The aim of this unique study was to consider the relationship between folate and vitamin B(12) on homocyst(e)ine (Hcy) concentration in an apparently healthy cohort of Welsh young people. A cohort of 179, 12-13 year olds (88 boys and 91 girls) were measured for Hcy, folate, vitamin B(12), adiposity, and dietary habits. Boys had significantly higher waist circumference and folate concentration than girls. Folate was negatively associated with Hcy in both sexes, whereas vitamin B(12) was negatively associated with Hcy in boys only. Adiposity was not associated with Hcy. Folate was an independent predictor of Hcy in both sexes, whilst vitamin B(12) was an independent determinant of Hcy in boys only. Familial history of cardiovascular disease (CVD) risk factors was identified in 69% of the children with elevated Hcy (> or = 8.5 mumol.L(-1)). Young people might be encouraged to increase their folate intake through diet, particularly by increasing their consumption of leafy vegetables and fruit. Further research is necessary to determine the exact contribution of genetics and diet on Hcy levels in young people, and whether Hcy levels during childhood and adolescence might influence future CVD risk.

  11. An LC-MS/MS-Based Method for the Quantification of Pyridox(am)ine 5'-Phosphate Oxidase Activity in Dried Blood Spots from Patients with Epilepsy.

    Science.gov (United States)

    Wilson, Matthew P; Footitt, Emma J; Papandreou, Apostolos; Uudelepp, Mari-Liis; Pressler, Ronit; Stevenson, Danielle C; Gabriel, Camila; McSweeney, Mel; Baggot, Matthew; Burke, Derek; Stödberg, Tommy; Riney, Kate; Schiff, Manuel; Heales, Simon J R; Mills, Kevin A; Gissen, Paul; Clayton, Peter T; Mills, Philippa B

    2017-09-05

    We report the development of a rapid, simple, and robust LC-MS/MS-based enzyme assay using dried blood spots (DBS) for the diagnosis of pyridox(am)ine 5'-phosphate oxidase (PNPO) deficiency (OMIM 610090). PNPO deficiency leads to potentially fatal early infantile epileptic encephalopathy, severe developmental delay, and other features of neurological dysfunction. However, upon prompt treatment with high doses of vitamin B 6 , affected patients can have a normal developmental outcome. Prognosis of these patients is therefore reliant upon a rapid diagnosis. PNPO activity was quantified by measuring pyridoxal 5'-phosphate (PLP) concentrations in a DBS before and after a 30 min incubation with pyridoxine 5'-phosphate (PNP). Samples from 18 PNPO deficient patients (1 day-25 years), 13 children with other seizure disorders receiving B 6 supplementation (1 month-16 years), and 37 child hospital controls (5 days-15 years) were analyzed. DBS from the PNPO-deficient samples showed enzyme activity levels lower than all samples from these two other groups as well as seven adult controls; no false positives or negatives were identified. The method was fully validated and is suitable for translation into the clinical diagnostic arena.

  12. Selectivity criterion for pyrazolo[3,4-b]pyrid[az]ine derivatives as GSK-3 inhibitors: CoMFA and molecular docking studies.

    Science.gov (United States)

    Patel, Dhilon S; Bharatam, Prasad V

    2008-05-01

    In the development of drugs targeted for GSK-3, its selective inhibition is an important requirement owing to the possibility of side effects arising from other kinases for the treatment of diabetes mellitus. A three-dimensional quantitative structure-activity relationship study (3D-QSAR) has been carried out on a set of pyrazolo[3,4-b]pyrid[az]ine derivatives, which includes non-selective and selective GSK-3 inhibitors. The CoMFA models were derived from a training set of 59 molecules. A test set containing 14 molecules (not used in model generation) was used to validate the CoMFA models. The best CoMFA model generated by applying leave-one-out (LOO) cross-validation study gave cross-validation r(cv)(2) and conventional r(conv)(2) values of 0.60 and 0.97, respectively, and r(pred)(2) value of 0.55, which provide the predictive ability of model. The developed models well explain (i) the observed variance in the activity and (ii) structural difference between the selective and non-selective GSK-3 inhibitors. Validation based on the molecular docking has also been carried out to explain the structural differences between the selective and non-selective molecules in the given series of molecules.

  13. Long-term nuclear knowledge management (NKM) of innovative nuclear energy systems (INES). A case study of the Japan Atomic Energy Research Institute (JAERI)

    International Nuclear Information System (INIS)

    Yanagisawa, Kazuaki; Bezdek, Roger H.; Sawada, Tetsuo

    2008-01-01

    Within JAERI, funds invested in a 45-year study of LWR totaled 4.2b$ for research and 3.4b$ (34,718 man years) for personnel. The benefits to taxpayers from this JAERI work were estimated to be about 6.3b$ , resulting in a favorable cost-benefit ratio of 1.5 (6.3/4.2). JAERI is a national research institute and this figure may be regarded as sufficiently high, and many high risk and complex tasks were completed successfully. Funds invested in the 32-year study of HTGR were 1.5b$ for R and D and 0.3b$ (2966 man years) for personnel. Commercialized HTGR will result in a cost reduction of electricity during power generation. Retail cost is 0.36b$/year and the share of JAERI (MCP) is 0.018b$/year. Funds invested in the 32-year study of FR were 5.4b$ for R and D and 0.6b$ (6331 man years) for personnel. Estimate is that after commercialization in 2050, a FR will generate revenue from electricity as high as 1687b$ during the period 2050-2100, or 34b$/year - which is greater than that of LWR. However, there is substantial uncertainty in these estimates. To achieve long-term INES, it is necessary to develop the sustainable scenarios and the long-term robust NKM, as shown in the present study. (author)

  14. Application of maximum radiation exposure values and monitoring of radiation exposure

    International Nuclear Information System (INIS)

    1996-01-01

    The guide presents the principles to be applied in calculating the equivalent dose and the effective dose, instructions on application of the maximum values for radiation exposure, and instruction on monitoring of radiation exposure. In addition, the measurable quantities to be used in monitoring the radiation exposure are presented. (2 refs.)

  15. The meaning and the principle of determination of the effective dose equivalent in radiation protection

    International Nuclear Information System (INIS)

    Drexler, G.; Williams, G.; Zankl, M.

    1985-01-01

    Since the introduction of the quantity ''effective dose equivalent'' within the framework of new radiation concepts, the meaning and interpretation of the quantity is often discussed and debated. Because of its adoption as a limiting quantity in many international and national laws, it is necessary to be able to interpret this main radiation protection quantity. Examples of organ doses and the related Hsub(E) values in occupational and medical exposures are presented and the meaning of the quantity is considered for whole body exposures to external and internal photon sources, as well as for partial body external exposures to photons. (author)

  16. Determination of skin dose reduction by lead equivalent gloves

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Abd Aziz Mhd Ramli

    2006-01-01

    Radiation protective gloves are always used in medical facilities to protect radiation workers from unnecessary radiation exposure. A study on radiation protection gloves which are produced by local company had been performed by the Medical Physics Group, MINT. The gloves were made of lead equivalent material, as the attenuating element. The gloves were evaluated in term of the percentage of skin dose reduction by using a newly developed procedure and facilities in MINT. Attenuation measurements of the gloves had been carried out using direct beams and scattered radiations of different qualities. TLD rings were fitted on finger phantom; and water phantom were used in the measurement. The result were obtained and analysed based on data supplied by manufacturer. (Author)

  17. The effective dose equivalent from external and internal radiation

    International Nuclear Information System (INIS)

    Mattsson, Soeren

    1989-01-01

    The various sources of low-level ionizing radiation are discussed and compared in terms of mean effective dose equivalent to man. For the most nonoccupationally exposed individuals, natural sources given the dominating contribution to the effective dose equivalent. The size of this contribution is strongly dependent on human activities. Natural sources contribution on average 2.4 mSV per year, of which half is due to irradiation of lungs and airways from short lived radon daughters present in indoor air. In Sweden this radon daughter contribution is considerably higher and contributes a mean of 3 mSv per year, thus giving a total contribution from natural radiation of about 4 mSV per year. In extreme cases, radon daughter contributions of several hundreds of mSv per year may be reached. Medical exposure, mainly diagnostic X-rays, contributes 0.4-1 mSv per year both in Sweden and as a world average. The testing of nuclear weapons in the atmosphere has given 1-2 mSv to each person in the world as a mean. The contribution from the routine operation of nuclear reactors is insignificant. The reactor accident in Chernobyl resulted in widely varying exposures of the European population. The average for Sweden is estimated to be 0.1 mSv during the first year and about 1 mSv during a 50-year period. For groups of Swedes who eat a considerable amount of game this contribution will be 10 times higher, and for the Lapps who breed reindeer in the most contaminated areas, typical values of 20-70 mSv and extreme values of about 1 Sv may be reached in 50 years. This means that the Chernobyl reactor accident for several years will be their dominating source of irradiation

  18. Metoprolol Dose Equivalence in Adult Men and Women Based on Gender Differences: Pharmacokinetic Modeling and Simulations

    Directory of Open Access Journals (Sweden)

    Andy R. Eugene

    2016-11-01

    Full Text Available Recent meta-analyses and publications over the past 15 years have provided evidence showing there are considerable gender differences in the pharmacokinetics of metoprolol. Throughout this time, there have not been any research articles proposing a gender stratified dose-adjustment resulting in an equivalent total drug exposure. Metoprolol pharmacokinetic data was obtained from a previous publication. Data was modeled using nonlinear mixed effect modeling using the MONOLIX software package to quantify metoprolol concentration–time data. Gender-stratified dosing simulations were conducted to identify equivalent total drug exposure based on a 100 mg dose in adults. Based on the pharmacokinetic modeling and simulations, a 50 mg dose in adult women provides an approximately similar metoprolol drug exposure to a 100 mg dose in adult men.

  19. On the equivalence of GPD representations

    International Nuclear Information System (INIS)

    Müller, Dieter; Semenov-Tian-Shansky, Kirill

    2016-01-01

    Phenomenological representations of generalized parton distributions (GPDs) implementing the non-trivial field theoretical requirements are employed in the present day strategies for extracting of hadron structure information encoded in GPDs from the observables of hard exclusive reactions. Showing out the equivalence of various GPD representations can help to get more insight into GPD properties and allow to build up flexible GPD models capable of satisfactory description of the whole set of available experimental data. Below we review the mathematical aspects of establishing equivalence between the the double partial wave expansion of GPDs in the conformal partial waves and in the t-channel SO(3) partial waves and the double distribution representation of GPDs

  20. Developing equivalent circuits for radial distribution networks

    Energy Technology Data Exchange (ETDEWEB)

    Prada, Ricardo; Coelho, Agnelo; Rodrigues, Anselmo [Catholic University of Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. of Electrical Engineering], Emails: prada@ele.puc-rio.br, agnelo@ele.puc-rio.br, nebulok_99@yahoo.com; Silva, Maria da Guia da [Federal University of Maranhao, Sao Luiz, MA (Brazil). Dept. of Electrical Engineering

    2009-07-01

    This paper presents a method for evaluating External Equivalent in Electric Distribution Networks (EDN).The proposed method has as its main objectives the reduction of the computational costs in distribution network reconfiguration, investigation of the optimal allocation of banks of capacitors, investigation of the allocation of distributed generation, etc. In these sorts of problems a large number of alternative projects must be assessed in order to identify the optimal solution. The optimal solution comes up with the voltage level in the load points within specified limits. Consequently, the EDN must retain the external network load points but without major increasing in the dimension of the equivalent circuit. The proposed method has been tested and validated in a substation of the Electricity Utility of Maranhao - CEMAR, in Brazil. (author)

  1. Thermoluminescence dosemeter for personal dose equivalent assessment

    International Nuclear Information System (INIS)

    Silva, T.A. da; Rosa, L.A.R. da; Campos, L.L.

    1995-01-01

    The possibility was investigated of utilising a Brazilian thermoluminescence individual dosemeter, usually calibrated in terms of photon dose equivalent, for the assessment of the personal dose equivalent, H p (d), at depths of 0.07 and 10 mm. The dosemeter uses four CaSO 4 :Dy thermoluminescent detectors, between different filters, as the sensitive materials. It was calibrated in gamma and X radiation fields in the energy range from 17 to 1250 keV. Linear combinations of the responses of three detectors, in this energy range, allow the evaluation of H p (0.07) and H p (10), for radiation incidence angles varying from 0 to 60 degrees, with an accuracy better than 35%. The method is not applicable to mixed photon-beta fields. (author)

  2. Thevenin Equivalent Method for Dynamic Contingency Assessment

    DEFF Research Database (Denmark)

    Møller, Jakob Glarbo; Jóhannsson, Hjörtur; Østergaard, Jacob

    2015-01-01

    A method that exploits Thevenin equivalent representation for obtaining post-contingency steady-state nodal voltages is integrated with a method of detecting post-contingency aperiodic small-signal instability. The task of integrating stability assessment with contingency assessment is challenged...... by the cases of unstable post-contingency conditions. For unstable postcontingency conditions there exists no credible steady-state which can be used for basis of a stability assessment. This paper demonstrates how Thevenin Equivalent methods can be applied in algebraic representation of such bifurcation...... points which may be used in assessment of post-contingency aperiodic small-signal stability. The assessment method is introduced with a numeric example....

  3. The Logic of Equivalence in Academic Discourse?

    DEFF Research Database (Denmark)

    Madsen, Dorte

    2017-01-01

    of discourse to distinguish between the scientific field, where interrelationships among academic disciplines are taken as an object of research, and the widespread uses of ‘interdisciplinary’ and ‘interdisciplinarity’ in academic discourse more generally, typically for legitimation purposes. The assumption......-discourses meet. It is suggested that the logics of signification, and the tension between difference and equivalence, may be important tools for theorizing this borderland. It is argued that whereas the logic of equivalence and the production of empty signifiers appears to be of marginal interest...... to the scientific field, the logic of difference as a more complex articulation of elements, seems to be more in line with the ideals of academic discourse....

  4. On equivalent resistance of electrical circuits

    Science.gov (United States)

    Kagan, Mikhail

    2015-01-01

    While the standard (introductory physics) way of computing the equivalent resistance of nontrivial electrical circuits is based on Kirchhoff's rules, there is a mathematically and conceptually simpler approach, called the method of nodal potentials, whose basic variables are the values of the electric potential at the circuit's nodes. In this paper, we review the method of nodal potentials and illustrate it using the Wheatstone bridge as an example. We then derive a closed-form expression for the equivalent resistance of a generic circuit, which we apply to a few sample circuits. The result unveils a curious interplay between electrical circuits, matrix algebra, and graph theory and its applications to computer science. The paper is written at a level accessible by undergraduate students who are familiar with matrix arithmetic. Additional proofs and technical details are provided in appendices.

  5. Symmetry adaptation, operator equivalents and magnetic resonance

    International Nuclear Information System (INIS)

    Kibler, M.; Chatterjee, R.

    1977-12-01

    Basic quantities for symmetry adaptation are discussed in connection with molecular and solid state physics. This gives rise to a formalism whose the central elements are operator equivalents adapted to a point group. Such symmetry adapted operator equivalents are defined in terms of Schwinger operators so that they cover the off-diagonal and diagonal cases. Special emphasis is put on the applications of the formalism to magnetic resonance. More specifically, it is shown how to apply the formalism to the construction, the study of the transformation properties, and the determination of the eigenstates of a generalized spin hamiltonian. Numerous examples are given as well as key tables relative to the chain SO(3) for making easy the application of the formalism to electron paramagnetic resonance [fr

  6. A Logical Characterisation of Static Equivalence

    DEFF Research Database (Denmark)

    Hüttel, Hans; Pedersen, Michael D.

    2007-01-01

    -order logic for frames with quantification over environment knowledge which, under certain general conditions, characterizes static equivalence and is amenable to construction of characteristic formulae. The logic can be used to reason about environment knowledge and can be adapted to a particular application...... by defining a suitable signature and associated equational theory. The logic can furthermore be extended with modalities to yield a modal logic for e.g. the Applied Pi calculus....

  7. Global equivalent magnetization of the oceanic lithosphere

    Science.gov (United States)

    Dyment, J.; Choi, Y.; Hamoudi, M.; Lesur, V.; Thebault, E.

    2015-11-01

    As a by-product of the construction of a new World Digital Magnetic Anomaly Map over oceanic areas, we use an original approach based on the global forward modeling of seafloor spreading magnetic anomalies and their comparison to the available marine magnetic data to derive the first map of the equivalent magnetization over the World's ocean. This map reveals consistent patterns related to the age of the oceanic lithosphere, the spreading rate at which it was formed, and the presence of mantle thermal anomalies which affects seafloor spreading and the resulting lithosphere. As for the age, the equivalent magnetization decreases significantly during the first 10-15 Myr after its formation, probably due to the alteration of crustal magnetic minerals under pervasive hydrothermal alteration, then increases regularly between 20 and 70 Ma, reflecting variations in the field strength or source effects such as the acquisition of a secondary magnetization. As for the spreading rate, the equivalent magnetization is twice as strong in areas formed at fast rate than in those formed at slow rate, with a threshold at ∼40 km/Myr, in agreement with an independent global analysis of the amplitude of Anomaly 25. This result, combined with those from the study of the anomalous skewness of marine magnetic anomalies, allows building a unified model for the magnetic structure of normal oceanic lithosphere as a function of spreading rate. Finally, specific areas affected by thermal mantle anomalies at the time of their formation exhibit peculiar equivalent magnetization signatures, such as the cold Australian-Antarctic Discordance, marked by a lower magnetization, and several hotspots, marked by a high magnetization.

  8. Visual Equivalence and Amodal Completion in Cuttlefish

    OpenAIRE

    Lin, I-Rong; Chiao, Chuan-Chin

    2017-01-01

    Modern cephalopods are notably the most intelligent invertebrates and this is accompanied by keen vision. Despite extensive studies investigating the visual systems of cephalopods, little is known about their visual perception and object recognition. In the present study, we investigated the visual processing of the cuttlefish Sepia pharaonis, including visual equivalence and amodal completion. Cuttlefish were trained to discriminate images of shrimp and fish using the operant conditioning pa...

  9. Canonizing certain Borel equivalences for Silver forcing

    Czech Academy of Sciences Publication Activity Database

    Doucha, Michal

    2012-01-01

    Roč. 159, č. 13 (2012), s. 2973-2979 ISSN 0166-8641. [Prague Symposium on General Topology and its Relations to Modern Analysis and Algebra /11./. Prague, 07.08.2011-12.08.2011] Institutional research plan: CEZ:AV0Z10190503 Keywords : Borel equivalence relations * silver ideal * canonical Ramsey theorem Subject RIV: BA - General Mathematics Impact factor: 0.562, year: 2012 http://www.sciencedirect.com/science/article/pii/S0166864112002180#

  10. Quantum mechanics from an equivalence principle

    International Nuclear Information System (INIS)

    Faraggi, A.E.

    1997-01-01

    The authors show that requiring diffeomorphic equivalence for one-dimensional stationary states implies that the reduced action S 0 satisfies the quantum Hamilton-Jacobi equation with the Planck constant playing the role of a covariantizing parameter. The construction shows the existence of a fundamental initial condition which is strictly related to the Moebius symmetry of the Legendre transform and to its involutive character. The universal nature of the initial condition implies the Schroedinger equation in any dimension

  11. Equivalency of two-dimensional algebras

    International Nuclear Information System (INIS)

    Santos, Gildemar Carneiro dos; Pomponet Filho, Balbino Jose S.

    2011-01-01

    Full text: Let us consider a vector z = xi + yj over the field of real numbers, whose basis (i,j) satisfy a given algebra. Any property of this algebra will be reflected in any function of z, so we can state that the knowledge of the properties of an algebra leads to more general conclusions than the knowledge of the properties of a function. However structural properties of an algebra do not change when this algebra suffers a linear transformation, though the structural constants defining this algebra do change. We say that two algebras are equivalent to each other whenever they are related by a linear transformation. In this case, we have found that some relations between the structural constants are sufficient to recognize whether or not an algebra is equivalent to another. In spite that the basis transform linearly, the structural constants change like a third order tensor, but some combinations of these tensors result in a linear transformation, allowing to write the entries of the transformation matrix as function of the structural constants. Eventually, a systematic way to find the transformation matrix between these equivalent algebras is obtained. In this sense, we have performed the thorough classification of associative commutative two-dimensional algebras, and find that even non-division algebra may be helpful in solving non-linear dynamic systems. The Mandelbrot set was used to have a pictorial view of each algebra, since equivalent algebras result in the same pattern. Presently we have succeeded in classifying some non-associative two-dimensional algebras, a task more difficult than for associative one. (author)

  12. Cryogenic test of the equivalence principle

    International Nuclear Information System (INIS)

    Worden, P.W. Jr.

    1976-01-01

    The weak equivalence principle is the hypothesis that the ratio of internal and passive gravitational mass is the same for all bodies. A greatly improved test of this principle is possible in an orbiting satellite. The most promising experiments for an orbital test are adaptations of the Galilean free-fall experiment and the Eotvos balance. Sensitivity to gravity gradient noise, both from the earth and from the spacecraft, defines a limit to the sensitivity in each case. This limit is generally much worse for an Eotvos balance than for a properly designed free-fall experiment. The difference is related to the difficulty of making a balance sufficiently isoinertial. Cryogenic technology is desirable to take full advantage of the potential sensitivity, but tides in the liquid helium refrigerant may produce a gravity gradient that seriously degrades the ultimate sensitivity. The Eotvos balance appears to have a limiting sensitivity to relative difference of rate of fall of about 2 x 10 -14 in orbit. The free-fall experiment is limited by helium tide to about 10 -15 ; if the tide can be controlled or eliminated the limit may approach 10 -18 . Other limitations to equivalence principle experiments are discussed. An experimental test of some of the concepts involved in the orbital free-fall experiment is continuing. The experiment consists in comparing the motions of test masses levitated in a superconducting magnetic bearing, and is itself a sensitive test of the equivalence principle. At present the levitation magnets, position monitors and control coils have been tested and major noise sources identified. A measurement of the equivalence principle is postponed pending development of a system for digitizing data. The experiment and preliminary results are described

  13. Extended equivalent dipole model for radiated emissions

    OpenAIRE

    Obiekezie, Chijioke S.

    2016-01-01

    This work is on the characterisation of radiated fields from electronic devices. An equivalent dipole approach is used. Previous work showed that this was an effective approach for single layer printed circuit boards where an infinite ground plane can be assumed. In this work, this approach is extended for the characterisation of more complex circuit boards or electronic systems.\\ud For complex electronic radiators with finite ground planes, the main challenge is characterising field diffract...

  14. Equivalence of Lagrangian and Hamiltonian BRST quantizations

    International Nuclear Information System (INIS)

    Grigoryan, G.V.; Grigoryan, R.P.; Tyutin, I.V.

    1992-01-01

    Two approaches to the quantization of gauge theories using BRST symmetry are widely used nowadays: the Lagrangian quantization, developed in (BV-quantization) and Hamiltonian quantization, formulated in (BFV-quantization). For all known examples of field theory (Yang-Mills theory, gravitation etc.) both schemes give equivalent results. However the equivalence of these approaches in general wasn't proved. The main obstacle in comparing of these formulations consists in the fact, that in Hamiltonian approach the number of ghost fields is equal to the number of all first-class constraints, while in the Lagrangian approach the number of ghosts is equal to the number of independent gauge symmetries, which is equal to the number of primary first-class constraints only. This paper is devoted to the proof of the equivalence of Lagrangian and Hamiltonian quantizations for the systems with first-class constraints only. This is achieved by a choice of special gauge in the Hamiltonian approach. It's shown, that after integration over redundant variables on the functional integral we come to effective action which is constructed according to rules for construction of the effective action in Lagrangian quantization scheme

  15. Energy conservation and the principle of equivalence

    International Nuclear Information System (INIS)

    Haugan, M.P.

    1979-01-01

    If the equivalence principle is violated, then observers performing local experiments can detect effects due to their position in an external gravitational environment (preferred-location effects) or can detect effects due to their velocity through some preferred frame (preferred frame effects). We show that the principle of energy conservation implies a quantitative connection between such effects and structure-dependence of the gravitational acceleration of test bodies (violation of the Weak Equivalence Principle). We analyze this connection within a general theoretical framework that encompasses both non-gravitational local experiments and test bodies as well as gravitational experiments and test bodies, and we use it to discuss specific experimental tests of the equivalence principle, including non-gravitational tests such as gravitational redshift experiments, Eoetvoes experiments, the Hughes-Drever experiment, and the Turner-Hill experiment, and gravitational tests such as the lunar-laser-ranging ''Eoetvoes'' experiment, and measurements of anisotropies and variations in the gravitational constant. This framework is illustrated by analyses within two theoretical formalisms for studying gravitational theories: the PPN formalism, which deals with the motion of gravitating bodies within metric theories of gravity, and the THepsilonμ formalism that deals with the motion of charged particles within all metric theories and a broad class of non-metric theories of gravity

  16. Dependence on age at intake of committed dose equivalents from radionuclides

    International Nuclear Information System (INIS)

    Adams, N.

    1981-01-01

    The dependence of committed dose equivalents on age at intake is needed to assess the significance of exposures of young persons among the general public resulting from inhaled or ingested radionuclides. The committed dose equivalents, evaluated using ICRP principles, depend on the body dimensions of the young person at the time of intake of a radionuclide and on subsequent body growth. Representation of growth by a series of exponential segments facilitates the derivation of general expressions for the age dependence of committed dose equivalents if metabolic models do not change with age. The additional assumption that intakes of radionuclides in air or food are proportional to a person's energy expenditure (implying age-independent dietary composition) enables the demonstration that the age of the most highly exposed 'critical groups' of the general public from these radionuclides is either about 1 year or 17 years. With the above assumptions the exposure of the critical group is less than three times the exposure of adult members of the general public. Approximate values of committed dose equivalents which avoid both underestimation and excessive overestimation are shown to be obtainable by simplified procedures. Modified procedures are suggested for use if metabolic models change with age. (author)

  17. Gauge equivalence of the Gross Pitaevskii equation and the equivalent Heisenberg spin chain

    Science.gov (United States)

    Radha, R.; Kumar, V. Ramesh

    2007-11-01

    In this paper, we construct an equivalent spin chain for the Gross-Pitaevskii equation with quadratic potential and exponentially varying scattering lengths using gauge equivalence. We have then generated the soliton solutions for the spin components S3 and S-. We find that the spin solitons for S3 and S- can be compressed for exponentially growing eigenvalues while they broaden out for decaying eigenvalues.

  18. Equivalent models of wind farms by using aggregated wind turbines and equivalent winds

    International Nuclear Information System (INIS)

    Fernandez, L.M.; Garcia, C.A.; Saenz, J.R.; Jurado, F.

    2009-01-01

    As a result of the increasing wind farms penetration on power systems, the wind farms begin to influence power system, and therefore the modeling of wind farms has become an interesting research topic. In this paper, new equivalent models of wind farms equipped with wind turbines based on squirrel-cage induction generators and doubly-fed induction generators are proposed to represent the collective behavior on large power systems simulations, instead of using a complete model of wind farms where all the wind turbines are modeled. The models proposed here are based on aggregating wind turbines into an equivalent wind turbine which receives an equivalent wind of the ones incident on the aggregated wind turbines. The equivalent wind turbine presents re-scaled power capacity and the same complete model as the individual wind turbines, which supposes the main feature of the present equivalent models. Two equivalent winds are evaluated in this work: (1) the average wind from the ones incident on the aggregated wind turbines with similar winds, and (2) an equivalent incoming wind derived from the power curve and the wind incident on each wind turbine. The effectiveness of the equivalent models to represent the collective response of the wind farm at the point of common coupling to grid is demonstrated by comparison with the wind farm response obtained from the detailed model during power system dynamic simulations, such as wind fluctuations and a grid disturbance. The present models can be used for grid integration studies of large power system with an important reduction of the model order and the computation time

  19. Exposure Forecaster

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Exposure Forecaster Database (ExpoCastDB) is EPA's database for aggregating chemical exposure information and can be used to help with chemical exposure...

  20. Microdosimetric basis for exposure limits

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Braby, L.A.

    1986-10-01

    The new organ-weighted effective dose equivalents should provide a much more accurate estimation of the degree of hazard for a worker's exposure to ionizing radiations. The method involves the microdosimetric concept of lineal energy to help establish exposure limits and will provide a unified system applicable to all types of ionizing radiation. Rather than being only calculated values, the effective dose equivalents and quality factors will be experimentally measured using tissue equivalent proportional counters. The measurement may be difficult to perform at various depths in an anthropomorphic phantom. Operational health physicists will be concerned about the lack of survey instruments and personnel dosimeters that measure lineal energy distributions. Their possible objections may be mitigated by the commercial introduction of instruments based upon tissue equivalent proportional counters or related devices containing inexpensive microprocessors. The many potential benefits include providing a uniform method for implementing the proposed increases in quality factors for neutrons and photons, providing a more unified approach for combining external and internal exposures, and potentially resolving questions about dosimeter placement and dose assessment for nonuniform exposures to mixed radiations. 16 refs., 3 figs

  1. Protective aprons in imaging departments: manufacturer stated lead equivalence values require validation

    International Nuclear Information System (INIS)

    Finnerty, M.; Brennan, P.C.

    2005-01-01

    The composition of protective aprons worn by X-ray personnel to shield against secondary radiation is changing. Lead is being replaced by either lead-free or composite (lead with other high atomic numbered elements) materials. These newer aprons are categorised by manufacturers in terms of lead equivalent values, but it is unclear how these stated values compare with actual lead equivalent values. In this work, the actual lead equivalence of 41 protective aprons from four manufacturers, all specified as having 0.25 mm lead equivalence, were investigated with transmission experiments at 70 and 100 kVp. All aprons were in current use. The aprons were screened for defects, and age, weight and design was recorded along with details of associated quality assurance (QA). Out of the 41 protective aprons examined for actual lead equivalence, 73% were outside tolerance levels, with actual levels in some aprons demonstrating less than half of the nominal values. The lack of compatibility between actual and nominal lead equivalent values was demonstrated by aprons from three of the four manufacturers investigated. The area of the defects found on screening of the protective aprons were within recommendations. The results highlight the need for acceptancy and ongoing checks of protective aprons to ensure that radiation exposure of imaging personnel is kept to a minimum. (orig.)

  2. Intake, evaluation of small ruminant nutrition system model and prediction of body composition of Santa Ines lambs fed diets with different levels of energy

    Directory of Open Access Journals (Sweden)

    Iana Sérvulo Gomes Maia

    2014-09-01

    Full Text Available The objective of this study was to evaluate the nutrient intake and suitability test of the SRNS nutritional model for dry matter intake (DMI and average daily gain (ADG, and Hankins and Howe equations to estimate the carcass and empty body chemical composition of 35 Santa Ines lambs, non-castrated, with initial body weight of 14.77 ± 1.26 kg and two months old. After 10 days of adaptation, five animals were slaughtered serving as reference group for estimates of empty body weight (EBW and initial body composition. The remaining animals were distributed in randomized block design with five treatments with different levels of metabolizable energy (1.13, 1.40, 1.73, 2.22 and 2.60 Mcal/kg DM. Quadratic effect was observed for DMI, expressed in g/d, % BW and g/BW0.75, with maximum DM intake of 867.25 g/d. Non fiber carbohydrates (NFC and total digestible nutrients (TDN intakes, expressed in g/d, increased with increases in ME levels and the intakes of neutral detergent fiber (NDF, acid detergent fiber (ADF and fibrous carbohydrates (FC, expressed in g/d, presented decreasing linear effect. The DMI and ADG observed and predicted by SRNS model showed a Pearson correlation coefficient of 0.68 and 0.98, respectively. Comparing the chemical composition of the carcass and HH section, observed that HH section estimated satisfactorily the protein and ether extract of carcass of animals, with Pearson correlation coefficient of 0.77 and 0.92, respectively, while the water content was underestimated with Pearson correlation coefficient of 0.42. The rib section also satisfactorily estimated to ether extract and protein in the empty body (r = 0.96 and 0.86, respectively.

  3. Occurrence of caseous lymphadenitis in sheep breed Santa Ines with surface reactive lymph nodes at Uberlândia region, Minas Gerais

    Directory of Open Access Journals (Sweden)

    Vinícius de Morais Barbosa

    2012-02-01

    Full Text Available This work aimed to evaluate the occurrence of caseous lymphadenitis and tuberculosis in Santa Ines sheep, with the presence of reactive superficial lymph nodes on clinical examination, it was examined 650 adult animals, between one and four years of age from 11 farms in the region of Uberlândia, Minas Gerais, Brazil. Tuberculin cervical comparative test (CCT was performed, as well as microbiological culture and polymerase chain reaction technique (PCR for positive cultures and serum samples for Corynebacterium pseudotuberculosis identification. From the total of 650 sheep examined, 14.6% (96/650 had at least one presented swelling superficial lymph node, and the frequency was: pre-scapular reactive lymph nodes (41.9%, submandibular (38.1%, parotid (14 3% and pre-crural (5.7%. The microbiological culture punctured material showed growth of Corynebacterium pseudotuberculosis in 81.8% of the samples (18/22, Staphylococcus sp and Escherichia coli in 4.6% (1/22 and no growth in 13.6% (3/22. All 18 samples of the culture of C. pseudotuberculosis were positive by PCR and only (3/22 serum samples positive by PCR. The TCC made of 96 sheep, 93 negative tests and 3 inconclusive. It is concluded that in Santa Inês sheep with the presence of swelling in superficial lymph node, the incidence of caseous lymphadenitis was 81.8% (18/22 and 3.1% (3/96 of animals were inconclusive in the tuberculin cervical comparative test.

  4. Novel phenotypes of pyridox(am)ine-5'-phosphate oxidase deficiency and high prevalence of c.445_448del mutation in Chinese patients.

    Science.gov (United States)

    Xue, Jiao; Chang, Xingzhi; Zhang, Yuehua; Yang, Zhixian

    2017-08-01

    To analyze the clinical and genetic characteristics of Chinese patients with pyridox(am)ine-5'-phosphate oxidase (PNPO) deficiency. The clinical presentations and the responses to treatments were analyzed in 4 patients. Blood and urinary metabolic screenings, electroencephalogram (EEG), brain magnetic resonance imaging (MRI) and epilepsy-related genes detection were performed in all patients. Patient 1 and 2 were identical twin brothers, who were born at 35 +5 w gestation with a sign of encephalopathy. Their seizures started within the first day and could not be controlled by pyridoxine or pyridoxal-5'-phosphate (PLP) completely. Patient 3 presented seizures at 5 months, responding well to pyridoxine. Seizures in patient 4 began at 40 days after birth and were controlled by valproic acid and topiramate. EEG showed atypical hypsarrhythmia or multifocal epileptiform discharges in 3 patients, and showed normality in patient 4. MRI showed nonspecific abnormality or normality. Blood metabolic screening showed multiple amino acids level abnormalities in all cases. Urinary metabolic screening showed vanillactic acid prominently elevated in 3 patients. Genetic analysis revealed 5 mutations of PNPO, three of which were novel. The mutation c.445_448del was carried by the twins and patient 3. Assessment of psychomotor development indicated severe delay in 3 patients and borderline to mild delay in patient 3. This is the first time to report patients with PNPO deficiency diagnosed by gene analysis in China. The novel clinical characteristics and novel mutations found here expanded the phenotypes and genotypes of this disease. Further, the frameshift mutation c.445_448del might be high prevalence in PNPO deficiency in Chinese patients.

  5. The use of the effective dose equivalent, Hsub(E), as a risk parameter in computed tomography

    International Nuclear Information System (INIS)

    Huda, W.; Sandison, G.A.

    1986-01-01

    This note employs the concept of the effective dose equivalent, Hsub(E) to overcome the problems of comparing the non-uniform radiation doses encountered in CT examinations with the whole-body dose-equivalent limits imposed for non-medical exposures for members of the public (5 mSv/year), or with the risks from familiar everyday activities such as smoking cigarettes or driving cars. (U.K.)

  6. Generating carbyne equivalents with photoredox catalysis

    Science.gov (United States)

    Wang, Zhaofeng; Herraiz, Ana G.; Del Hoyo, Ana M.; Suero, Marcos G.

    2018-02-01

    Carbon has the unique ability to bind four atoms and form stable tetravalent structures that are prevalent in nature. The lack of one or two valences leads to a set of species—carbocations, carbanions, radicals and carbenes—that is fundamental to our understanding of chemical reactivity. In contrast, the carbyne—a monovalent carbon with three non-bonded electrons—is a relatively unexplored reactive intermediate; the design of reactions involving a carbyne is limited by challenges associated with controlling its extreme reactivity and the lack of efficient sources. Given the innate ability of carbynes to form three new covalent bonds sequentially, we anticipated that a catalytic method of generating carbynes or related stabilized species would allow what we term an ‘assembly point’ disconnection approach for the construction of chiral centres. Here we describe a catalytic strategy that generates diazomethyl radicals as direct equivalents of carbyne species using visible-light photoredox catalysis. The ability of these carbyne equivalents to induce site-selective carbon-hydrogen bond cleavage in aromatic rings enables a useful diazomethylation reaction, which underpins sequencing control for the late-stage assembly-point functionalization of medically relevant agents. Our strategy provides an efficient route to libraries of potentially bioactive molecules through the installation of tailored chiral centres at carbon-hydrogen bonds, while complementing current translational late-stage functionalization processes. Furthermore, we exploit the dual radical and carbene character of the generated carbyne equivalent in the direct transformation of abundant chemical feedstocks into valuable chiral molecules.

  7. Equivalent conserved currents and generalized Noether's theorem

    International Nuclear Information System (INIS)

    Gordon, T.J.

    1984-01-01

    A generalized Noether theorem is presented, relating symmetries and equivalence classes of local) conservation laws in classical field theories; this is contrasted with the standard theorem. The concept of a ''Noether'' field theory is introduced, being a theory for which the generalized theorem applies; not only does this include the cases of Lagrangian and Hamiltonian field theories, these structures are ''derived'' from the Noether property in a natural way. The generalized theorem applies to currents and symmetries that contain derivatives of the fields up to an arbitrarily high order

  8. Gravitational leptogenesis, C, CP and strong equivalence

    International Nuclear Information System (INIS)

    McDonald, Jamie I.; Shore, Graham M.

    2015-01-01

    The origin of matter-antimatter asymmetry is one of the most important outstanding problems at the interface of particle physics and cosmology. Gravitational leptogenesis (baryogenesis) provides a possible mechanism through explicit couplings of spacetime curvature to appropriate lepton (or baryon) currents. In this paper, the idea that these strong equivalence principle violating interactions could be generated automatically through quantum loop effects in curved spacetime is explored, focusing on the realisation of the discrete symmetries C, CP and CPT which must be broken to induce matter-antimatter asymmetry. The related issue of quantum corrections to the dispersion relation for neutrino propagation in curved spacetime is considered within a fully covariant framework.

  9. European Equivalencies in Legal Interpreting and Translation

    DEFF Research Database (Denmark)

    Corsellis, Ann; Hertog, Erik; Martinsen, Bodil

    2002-01-01

    Within Europe there is increasing freedom of movement between countries and increasing inward migration. As a result, equivalent standards of legl interpreting and translation are required to allow reliable communication for judicial cooperation between member states, for criminal and civil matters...... which cross national borders and for the needs of multilingual populations. The European Convention of Human Rights (article 6, paragrph 3) is one of the main planks of relevant legislation. This international, two year project has been funded by the EU Grotius programme to set out what is required...

  10. Testing efficiency transfer codes for equivalence

    International Nuclear Information System (INIS)

    Vidmar, T.; Celik, N.; Cornejo Diaz, N.; Dlabac, A.; Ewa, I.O.B.; Carrazana Gonzalez, J.A.; Hult, M.; Jovanovic, S.; Lepy, M.-C.; Mihaljevic, N.; Sima, O.; Tzika, F.; Jurado Vargas, M.; Vasilopoulou, T.; Vidmar, G.

    2010-01-01

    Four general Monte Carlo codes (GEANT3, PENELOPE, MCNP and EGS4) and five dedicated packages for efficiency determination in gamma-ray spectrometry (ANGLE, DETEFF, GESPECOR, ETNA and EFFTRAN) were checked for equivalence by applying them to the calculation of efficiency transfer (ET) factors for a set of well-defined sample parameters, detector parameters and energies typically encountered in environmental radioactivity measurements. The differences between the results of the different codes never exceeded a few percent and were lower than 2% in the majority of cases.

  11. The equivalence principle in a quantum world

    DEFF Research Database (Denmark)

    Bjerrum-Bohr, N. Emil J.; Donoghue, John F.; El-Menoufi, Basem Kamal

    2015-01-01

    the energy is small, we now have the tools to address this conflict explicitly. Despite the violation of some classical concepts, the EP continues to provide the core of the quantum gravity framework through the symmetry - general coordinate invariance - that is used to organize the effective field theory......We show how modern methods can be applied to quantum gravity at low energy. We test how quantum corrections challenge the classical framework behind the equivalence principle (EP), for instance through introduction of nonlocality from quantum physics, embodied in the uncertainty principle. When...

  12. Equivalent Circuit Modeling of Hysteresis Motors

    Energy Technology Data Exchange (ETDEWEB)

    Nitao, J J; Scharlemann, E T; Kirkendall, B A

    2009-08-31

    We performed a literature review and found that many equivalent circuit models of hysteresis motors in use today are incorrect. The model by Miyairi and Kataoka (1965) is the correct one. We extended the model by transforming it to quadrature coordinates, amenable to circuit or digital simulation. 'Hunting' is an oscillatory phenomenon often observed in hysteresis motors. While several works have attempted to model the phenomenon with some partial success, we present a new complete model that predicts hunting from first principles.

  13. Money and bonds: an equivalence theorem

    OpenAIRE

    Narayana R. Kocherlakota

    2007-01-01

    This paper considers four models in which immortal agents face idiosyncratic shocks and trade only a single risk-free asset over time. The four models specify this single asset to be private bonds, public bonds, public money, or private money respectively. I prove that, given an equilibrium in one of these economies, it is possible to pick the exogenous elements in the other three economies so that there is an outcome-equivalent equilibrium in each of them. (The term ?exogenous variables? ref...

  14. Gravitational leptogenesis, C, CP and strong equivalence

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, Jamie I.; Shore, Graham M. [Department of Physics, Swansea University,Swansea, SA2 8PP (United Kingdom)

    2015-02-12

    The origin of matter-antimatter asymmetry is one of the most important outstanding problems at the interface of particle physics and cosmology. Gravitational leptogenesis (baryogenesis) provides a possible mechanism through explicit couplings of spacetime curvature to appropriate lepton (or baryon) currents. In this paper, the idea that these strong equivalence principle violating interactions could be generated automatically through quantum loop effects in curved spacetime is explored, focusing on the realisation of the discrete symmetries C, CP and CPT which must be broken to induce matter-antimatter asymmetry. The related issue of quantum corrections to the dispersion relation for neutrino propagation in curved spacetime is considered within a fully covariant framework.

  15. Integrable topological billiards and equivalent dynamical systems

    Science.gov (United States)

    Vedyushkina, V. V.; Fomenko, A. T.

    2017-08-01

    We consider several topological integrable billiards and prove that they are Liouville equivalent to many systems of rigid body dynamics. The proof uses the Fomenko-Zieschang theory of invariants of integrable systems. We study billiards bounded by arcs of confocal quadrics and their generalizations, generalized billiards, where the motion occurs on a locally planar surface obtained by gluing several planar domains isometrically along their boundaries, which are arcs of confocal quadrics. We describe two new classes of integrable billiards bounded by arcs of confocal quadrics, namely, non-compact billiards and generalized billiards obtained by gluing planar billiards along non-convex parts of their boundaries. We completely classify non-compact billiards bounded by arcs of confocal quadrics and study their topology using the Fomenko invariants that describe the bifurcations of singular leaves of the additional integral. We study the topology of isoenergy surfaces for some non-convex generalized billiards. It turns out that they possess exotic Liouville foliations: the integral trajectories of the billiard that lie on some singular leaves admit no continuous extension. Such billiards appear to be leafwise equivalent to billiards bounded by arcs of confocal quadrics in the Minkowski metric.

  16. Twisted conformal field theories and Morita equivalence

    Energy Technology Data Exchange (ETDEWEB)

    Marotta, Vincenzo [Dipartimento di Scienze Fisiche, Universita di Napoli ' Federico II' and INFN, Sezione di Napoli, Compl. universitario M. Sant' Angelo, Via Cinthia, 80126 Napoli (Italy); Naddeo, Adele [CNISM, Unita di Ricerca di Salerno and Dipartimento di Fisica ' E.R. Caianiello' , Universita degli Studi di Salerno, Via Salvador Allende, 84081 Baronissi (Italy); Dipartimento di Scienze Fisiche, Universita di Napoli ' Federico II' , Compl. universitario M. Sant' Angelo, Via Cinthia, 80126 Napoli (Italy)], E-mail: adelenaddeo@yahoo.it

    2009-04-01

    The Morita equivalence for field theories on noncommutative two-tori is analysed in detail for rational values of the noncommutativity parameter {theta} (in appropriate units): an isomorphism is established between an Abelian noncommutative field theory (NCFT) and a non-Abelian theory of twisted fields on ordinary space. We focus on a particular conformal field theory (CFT), the one obtained by means of the m-reduction procedure [V. Marotta, J. Phys. A 26 (1993) 3481; V. Marotta, Mod. Phys. Lett. A 13 (1998) 853; V. Marotta, Nucl. Phys. B 527 (1998) 717; V. Marotta, A. Sciarrino, Mod. Phys. Lett. A 13 (1998) 2863], and show that it is the Morita equivalent of a NCFT. Finally, the whole m-reduction procedure is shown to be the image in the ordinary space of the Morita duality. An application to the physics of a quantum Hall fluid at Jain fillings {nu}=m/(2pm+1) is explicitly discussed in order to further elucidate such a correspondence and to clarify its role in the physics of strongly correlated systems. A new picture emerges, which is very different from the existing relationships between noncommutativity and many body systems [A.P. Polychronakos, arXiv: 0706.1095].

  17. Planck Constant Determination from Power Equivalence

    Science.gov (United States)

    Newell, David B.

    2000-04-01

    Equating mechanical to electrical power links the kilogram, the meter, and the second to the practical realizations of the ohm and the volt derived from the quantum Hall and the Josephson effects, yielding an SI determination of the Planck constant. The NIST watt balance uses this power equivalence principle, and in 1998 measured the Planck constant with a combined relative standard uncertainty of 8.7 x 10-8, the most accurate determination to date. The next generation of the NIST watt balance is now being assembled. Modification to the experimental facilities have been made to reduce the uncertainty components from vibrations and electromagnetic interference. A vacuum chamber has been installed to reduce the uncertainty components associated with performing the experiment in air. Most of the apparatus is in place and diagnostic testing of the balance should begin this year. Once a combined relative standard uncertainty of one part in 10-8 has been reached, the power equivalence principle can be used to monitor the possible drift in the artifact mass standard, the kilogram, and provide an accurate alternative definition of mass in terms of fundamental constants. *Electricity Division, Electronics and Electrical Engineering Laboratory, Technology Administration, U.S. Department of Commerce. Contribution of the National Institute of Standards and Technology, not subject to copyright in the U.S.

  18. Evaluación de impacto de un centro de innovación educativa (INED) en Chiapas, México: una mirada desde la evaluación cualitativa

    OpenAIRE

    Estrada, Marcos J.

    2009-01-01

    El presente texto discute dos conceptos relacionados: buenas prácticas e innovación educativa, destacando que la primera es parte de un proceso más amplio denominado “innovación educativa”. A través de dos recortes de evaluación de impacto se analizan los aportes de un centro de innovación educativa ubicado en el estado mexicano de Chiapas. Se destaca en específico que INED contribuye al campo educativo en dos indicadores relevantes con los actores de la comunidad educativa con los que trabaj...

  19. Odabir optimalne prostorne rezolucije fotogrametrijskih digitalnih modela površine za primjenu u šumarstvu – primjer s područja nizinskih šuma hrasta lužnjaka

    OpenAIRE

    Balenović, Ivan; Marjanović, Hrvoje

    2016-01-01

    Posljednjih godina digitalna aerofotogrametrija počinje se primjenjivati kao alternativna metoda zračnomu laserskomu skeniranju u trodimenzionalnom modeliranju šumskih površina, poglavito u izradi digitalnih modela površine (DSM-ova). Za potrebe inventure šuma DSM se uglavnom koristi u kombinaciji s digitalnim modelom reljefa, preklapanjem kojih se dobije digitalni model visine sastojina/krošanja (CHM) koji se potom koristi za procjenu različitih varijabli pojedinačnih stabala ili šumskih sas...

  20. Equivalent sphere approximations for skin, eye, and blood-forming organs

    International Nuclear Information System (INIS)

    Maxson, W.L.; Townsend, L.W.; Bier, S.G.

    1996-01-01

    Throughout the manned spaceflight program, protecting astronauts from space radiation has been the subject of intense study. For interplanetary crews, two main sources of radiation hazards are solar particle events (SPEs) and galactic cosmic rays. For nearly three decades, crew doses and related shielding requirements have been assessed using the assumption that body organ exposures are well approximated by exposures at the center of tissue-equivalent spheres. For the skin and for blood-forming organs (BFOs), these spheres have radii of 0 and 5 cm, respectively. Recent studies indicate that significant overestimation of organ doses occurs if these models are used instead of realistic human geometry models. The use of the latter, however, requires much longer computational times. In this work, the authors propose preliminary revisions to these equivalent sphere approximations that yield more realistic dose estimates

  1. Simulated Response of a Tissue-equivalent Proportional Counter on the Surface of Mars.

    Science.gov (United States)

    Northum, Jeremy D; Guetersloh, Stephen B; Braby, Leslie A; Ford, John R

    2015-10-01

    Uncertainties persist regarding the assessment of the carcinogenic risk associated with galactic cosmic ray (GCR) exposure during a mission to Mars. The GCR spectrum peaks in the range of 300(-1) MeV n to 700 MeV n(-1) and is comprised of elemental ions from H to Ni. While Fe ions represent only 0.03% of the GCR spectrum in terms of particle abundance, they are responsible for nearly 30% of the dose equivalent in free space. Because of this, radiation biology studies focusing on understanding the biological effects of GCR exposure generally use Fe ions. Acting as a thin shield, the Martian atmosphere alters the GCR spectrum in a manner that significantly reduces the importance of Fe ions. Additionally, albedo particles emanating from the regolith complicate the radiation environment. The present study uses the Monte Carlo code FLUKA to simulate the response of a tissue-equivalent proportional counter on the surface of Mars to produce dosimetry quantities and microdosimetry distributions. The dose equivalent rate on the surface of Mars was found to be 0.18 Sv y(-1) with an average quality factor of 2.9 and a dose mean lineal energy of 18.4 keV μm(-1). Additionally, albedo neutrons were found to account for 25% of the dose equivalent. It is anticipated that these data will provide relevant starting points for use in future risk assessment and mission planning studies.

  2. Borel equivalence relations structure and classification

    CERN Document Server

    Kanovei, Vladimir

    2008-01-01

    Over the last 20 years, the theory of Borel equivalence relations and related topics have been very active areas of research in set theory and have important interactions with other fields of mathematics, like ergodic theory and topological dynamics, group theory, combinatorics, functional analysis, and model theory. The book presents, for the first time in mathematical literature, all major aspects of this theory and its applications. This book should be of interest to a wide spectrum of mathematicians working in set theory as well as the other areas mentioned. It provides a systematic exposition of results that so far have been only available in journals or are even unpublished. The book presents unified and in some cases significantly streamlined proofs of several difficult results, especially dichotomy theorems. It has rather minimal overlap with other books published in this subject.

  3. Characterization of Destrins with Different Dextrose Equivalents

    Directory of Open Access Journals (Sweden)

    Guanglei Li

    2010-07-01

    Full Text Available Dextrins are widely used for their functional properties and prepared by partial hydrolysis of starch using acid, enzymes, or combinations of both. The physiochemical properties of dextrins are dependent on their molecular distribution and oligosaccharide profiles. In this study, scanning electron microscopy (SEM, X-ray diffractometry (XRD, rapid viscoanalysis (RVA, high-performance Liquid Chromatography (HPLC and gel permeation chromatography (GPC were used to characterize dextrins prepared by common neutral and thermostable α-amylase hydrolysis. The dextrin granules displayed irregular surfaces and were badly damaged by the enzyme treatment. They displayed A-type X-ray diffraction patterns with a decrease of intensity of the characteristic diffraction peaks. The RVA profiles showed that the viscosity of dextrin decreased with the increase of its Dextrose Equivalent (DE value. According to HPLC analysis, the molecular weight, degree of polymerization and the composition of oligosaccharides in dextrins were different.

  4. Multiplicities of states od equivalent fermion shells

    International Nuclear Information System (INIS)

    Savukinas, A.Yu.; Glembotskij, I.I.

    1980-01-01

    Classification of states of three or four equivalent fermions has been studied, i.e. possible terms and their multiplicities have been determined. For this purpose either the group theory or evident expressions for the fractional-parentage coefficients have been used. In the first approach the formulas obtained by other authors for the multiplicities of terms through the characters of the transformation matrices of bond moments have been used. This approach happens to be more general as compared with the second one, as expressions for the fractional-parentage coefficients in many cases are not known. The multiplicities of separate terms have been determined. It has been shown that the number of terms of any multiplicity becomes constant when l or j is increased [ru

  5. Sample size allocation in multiregional equivalence studies.

    Science.gov (United States)

    Liao, Jason J Z; Yu, Ziji; Li, Yulan

    2018-06-17

    With the increasing globalization of drug development, the multiregional clinical trial (MRCT) has gained extensive use. The data from MRCTs could be accepted by regulatory authorities across regions and countries as the primary sources of evidence to support global marketing drug approval simultaneously. The MRCT can speed up patient enrollment and drug approval, and it makes the effective therapies available to patients all over the world simultaneously. However, there are many challenges both operationally and scientifically in conducting a drug development globally. One of many important questions to answer for the design of a multiregional study is how to partition sample size into each individual region. In this paper, two systematic approaches are proposed for the sample size allocation in a multiregional equivalence trial. A numerical evaluation and a biosimilar trial are used to illustrate the characteristics of the proposed approaches. Copyright © 2018 John Wiley & Sons, Ltd.

  6. Equivalence principle and the baryon acoustic peak

    Science.gov (United States)

    Baldauf, Tobias; Mirbabayi, Mehrdad; Simonović, Marko; Zaldarriaga, Matias

    2015-08-01

    We study the dominant effect of a long wavelength density perturbation δ (λL) on short distance physics. In the nonrelativistic limit, the result is a uniform acceleration, fixed by the equivalence principle, and typically has no effect on statistical averages due to translational invariance. This same reasoning has been formalized to obtain a "consistency condition" on the cosmological correlation functions. In the presence of a feature, such as the acoustic peak at ℓBAO, this naive expectation breaks down for λLexplicitly applied to the one-loop calculation of the power spectrum. Finally, the success of baryon acoustic oscillation reconstruction schemes is argued to be another empirical evidence for the validity of the results.

  7. Development of air equivalent gamma dose monitor

    International Nuclear Information System (INIS)

    Alex, Mary; Bhattacharya, Sadhana; Karpagam, R.; Prasad, D.N.; Jakati, R.K.; Mukhopadhyay, P.K.; Patil, R.K.

    2010-01-01

    The paper describes design and development of air equivalent gamma absorbed dose monitor. The monitor has gamma sensitivity of 84 pA/R/h for 60 Co source. The characterization of the monitor has been done to get energy dependence on gamma sensitivity and response to gamma radiation field from 1 R/hr to 5000 R/hr. The gamma sensitivity in the energy range of 0.06 to 1.25MeV relative to 137 Cs nuclide was within 2.5%. The linearity of the monitor response as a function of gamma field from 10 R/h to 3.8 kR/h was within 6%. The monitor has been designed for its application in harsh environment. It has been successfully qualified to meet environmental requirements of shock. (author)

  8. A new concept of equivalent homogenization method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Jin; Pogoskekyan, Leonid; Kim, Young Il; Ju, Hyung Kook; Chang, Moon Hee [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-07-01

    A new concept of equivalent homogenization is proposed. The concept employs new set of homogenized parameters: homogenized cross sections (XS) and interface matrix (IM), which relates partial currents at the cell interfaces. The idea of interface matrix generalizes the idea of discontinuity factors (DFs), proposed and developed by K. Koebke and K. Smith. The offered concept covers both those of K. Koebke and K. Smith; both of them can be simulated within framework of new concept. Also, the offered concept covers Siemens KWU approach for baffle/reflector simulation, where the equivalent homogenized reflector XS are derived from the conservation of response matrix at the interface in 1D simi-infinite slab geometry. The IM and XS of new concept satisfy the same assumption about response matrix conservation in 1D semi-infinite slab geometry. It is expected that the new concept provides more accurate approximation of heterogeneous cell, especially in case of the steep flux gradients at the cell interfaces. The attractive shapes of new concept are: improved accuracy, simplicity of incorporation in the existing codes, equal numerical expenses in comparison to the K. Smith`s approach. The new concept is useful for: (a) explicit reflector/baffle simulation; (b) control blades simulation; (c) mixed UO{sub 2}/MOX core simulation. The offered model has been incorporated in the finite difference code and in the nodal code PANDOX. The numerical results show good accuracy of core calculations and insensitivity of homogenized parameters with respect to in-core conditions. 9 figs., 7 refs. (Author).

  9. Equivalence principle implications of modified gravity models

    International Nuclear Information System (INIS)

    Hui, Lam; Nicolis, Alberto; Stubbs, Christopher W.

    2009-01-01

    Theories that attempt to explain the observed cosmic acceleration by modifying general relativity all introduce a new scalar degree of freedom that is active on large scales, but is screened on small scales to match experiments. We demonstrate that if such screening occurs via the chameleon mechanism, such as in f(R) theory, it is possible to have order unity violation of the equivalence principle, despite the absence of explicit violation in the microscopic action. Namely, extended objects such as galaxies or constituents thereof do not all fall at the same rate. The chameleon mechanism can screen the scalar charge for large objects but not for small ones (large/small is defined by the depth of the gravitational potential and is controlled by the scalar coupling). This leads to order one fluctuations in the ratio of the inertial mass to gravitational mass. We provide derivations in both Einstein and Jordan frames. In Jordan frame, it is no longer true that all objects move on geodesics; only unscreened ones, such as test particles, do. In contrast, if the scalar screening occurs via strong coupling, such as in the Dvali-Gabadadze-Porrati braneworld model, equivalence principle violation occurs at a much reduced level. We propose several observational tests of the chameleon mechanism: 1. small galaxies should accelerate faster than large galaxies, even in environments where dynamical friction is negligible; 2. voids defined by small galaxies would appear larger compared to standard expectations; 3. stars and diffuse gas in small galaxies should have different velocities, even if they are on the same orbits; 4. lensing and dynamical mass estimates should agree for large galaxies but disagree for small ones. We discuss possible pitfalls in some of these tests. The cleanest is the third one where the mass estimate from HI rotational velocity could exceed that from stars by 30% or more. To avoid blanket screening of all objects, the most promising place to look is in

  10. Doses from radiation exposure

    International Nuclear Information System (INIS)

    Menzel, H-G.; Harrison, J.D.

    2012-01-01

    Practical implementation of the International Commission on Radiological Protection’s (ICRP) system of protection requires the availability of appropriate methods and data. The work of Committee 2 is concerned with the development of reference data and methods for the assessment of internal and external radiation exposure of workers and members of the public. This involves the development of reference biokinetic and dosimetric models, reference anatomical models of the human body, and reference anatomical and physiological data. Following ICRP’s 2007 Recommendations, Committee 2 has focused on the provision of new reference dose coefficients for external and internal exposure. As well as specifying changes to the radiation and tissue weighting factors used in the calculation of protection quantities, the 2007 Recommendations introduced the use of reference anatomical phantoms based on medical imaging data, requiring explicit sex averaging of male and female organ-equivalent doses in the calculation of effective dose. In preparation for the calculation of new dose coefficients, Committee 2 and its task groups have provided updated nuclear decay data (ICRP Publication 107) and adult reference computational phantoms (ICRP Publication 110). New dose coefficients for external exposures of workers are complete (ICRP Publication 116), and work is in progress on a series of reports on internal dose coefficients to workers from inhaled and ingested radionuclides. Reference phantoms for children will also be provided and used in the calculation of dose coefficients for public exposures. Committee 2 also has task groups on exposures to radiation in space and on the use of effective dose.

  11. Polymorphisme de l'apolipoprotéine E dans la population du nord du Maroc: fréquence et influence sur les paramètres lipidiques

    Science.gov (United States)

    Benyahya, Fatiha; Barakat, Amina; Ghailani, Naima; Bennani, Mohcine

    2013-01-01

    Introduction L'objectif de ce travail est de déterminer les fréquences alléliques et génotypiques des sites polymorphes situés dans le gène de l'apolipoprotéine E (apo E) ainsi que leur impact sur les paramètres cliniques et lipidiques dans un échantillon de la population du nord du Maroc cliniquement diagnostiqué ADH. Méthodes Le génotype de l'apo E a été analysé par séquençage direct chez 46 patients cliniquement diagnostiqués ADH selon les critères standards. Résultats Les fréquences des allèles epsilon 3, epsilon 2 et epsilon 4 ont été respectivement 78.3%, 2.2% et 19.6%. La fréquence de l'allèle epsilon 4 est très élevée chez la population du nord du Maroc en comparaison avec les populations des autres régions marocaines. Elle est similaire à celle rapportée dans les pays de l'Europe du nord. Les taux du cholestérol total, du cholestérol LDL ainsi que la présence des xanthomes et les maladies cardiovasculaires ne différent pas entre les génotypes de l'apoE. En revanche, les résultats ont montré une influence de l'allèle epsilon4 sur le taux des triglycérides chez les sujets obèses. Conclusion Le génotype de l'apoE ne peut expliquer le phénotype clinique et biochimique présenté par des patients du Nord du Maroc cliniquement diagnostiqués ADH. PMID:24396563

  12. Uso tradicional de plantas medicinales con acción diurética en el Municipio de Quemado de Güines, Cuba

    Directory of Open Access Journals (Sweden)

    Maykel Pérez Machín

    2011-12-01

    Full Text Available La flora de Cuba es muy rica en plantas medicinales, de las cuales se reportan aproximadamente 179 especies que la población utiliza para fines diuréticos, sin embargo, un gran número de ellas carece de validación experimental de su efecto farmacológico. El presente estudio se realizó con el propósito de documentar la importancia relativa de las especies medicinales más empleadas con fines diuréticos en el municipio de Quemado de Güines de la provincia de Villa Clara, Cuba. Se realizó un estudio etnobotánico en dos comunidades pertenecientes a ese municipio, para lo cual se realizó un muestreo a un total de 85 habitantes, y se aplicó aleatoriamente 80 encuestas a conocedores de plantas y 5 entrevistas entre yerberos y médicos practicantes de medicina tradicional, los cuales nos indicaron las plantas más utilizadas con estos fines en las comunidades estudiadas. La información etnofarmacológica fue registrada mediante la metodología TRAMIL y las especies de interés fueron identificadas y depositadas en el Herbario de la Universidad Central "Marta Abreu" de Las Villas. Los datos se analizaron mediante los índices cuantitativos de valor de uso para cada especie (IVU y el nivel de uso significativo (UST. Este indicador expresa que aquellos usos medicinales que son citados con una frecuencia superior o igual al 20%, por las personas encuestadas pueden considerarse significativos desde el punto de vista de su aceptación cultural y, por lo tanto, merecen su validación científica en Cuba. Se identificaron 26 especies medicinales agrupadas en 19 familias botánicas y se encontraron 10 plantas con un mayor nivel de uso significativo y un mayor IVU. El 53.8% de las plantas reportadas como diuréticas no se han validado experimentalmente en Cuba, el resto de las especies identificadas han sido estudiadas a nivel preclínico, pero aún no está autorizado su empleo como fitomedicamento.

  13. 49 CFR 391.33 - Equivalent of road test.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Equivalent of road test. 391.33 Section 391.33... AND LONGER COMBINATION VEHICLE (LCV) DRIVER INSTRUCTORS Tests § 391.33 Equivalent of road test. (a) In place of, and as equivalent to, the road test required by § 391.31, a person who seeks to drive a...

  14. A bicategorical approach to Morita equivalence for Von Neumann algebras

    NARCIS (Netherlands)

    R.M. Brouwer (Rachel)

    2003-01-01

    textabstractWe relate Morita equivalence for von Neumann algebras to the ``Connes fusion'' tensor product between correspondences. In the purely algebraic setting, it is well known that rings are Morita equivalent if and only if they are equivalent objects in a bicategory whose 1-cells are

  15. Problems of Equivalence in Shona- English Bilingual Dictionaries

    African Journals Online (AJOL)

    rbr

    Page 1 ... translation equivalents in Shona-English dictionaries where lexicographers will be dealing with divergent languages and cultures, traditional practices of lexicography and the absence of reliable ... ideal in translation is to achieve structural and semantic equivalence. Absolute equivalence between any two ...

  16. The equivalence principle in classical mechanics and quantum mechanics

    OpenAIRE

    Mannheim, Philip D.

    1998-01-01

    We discuss our understanding of the equivalence principle in both classical mechanics and quantum mechanics. We show that not only does the equivalence principle hold for the trajectories of quantum particles in a background gravitational field, but also that it is only because of this that the equivalence principle is even to be expected to hold for classical particles at all.

  17. Applicability of ambient dose equivalent H*(d) in mixed radiation fields - a critical discussion

    International Nuclear Information System (INIS)

    Hajek, M.; Vana, N.

    2004-01-01

    For purposes of routine radiation protection, it is desirable to characterize the potential irradiation of individuals in terms of a single dose equivalent quantity that would exist in a phantom approximating the human body. The phantom of choice is the ICRU sphere made of 30 cm diameter tissue-equivalent plastic with a density of 1 g.cm-3 and a mass composition of 76.2 % O, 11.1 % C, 10.1 % H and 2.6 % N. Ambient dose equivalent, H*(d), was defined in ICRU report 51 as the dose equivalent that would be produced by an expanded and aligned radiation field at a depth d in the ICRU sphere. The recommended reference depths are 10 mm for strongly penetrating radiation and 0.07 mm for weakly penetrating radiation, respectively. As an operational quantity in radiation protection, H*(d) shall serve as a conservative and directly measurable estimate of protection quantities, e.g. effective dose E, which in turn are intended to give an indication of the risk associated with radiation exposure. The situation attains increased complexity in radiation environments being composed of a variety of charged and uncharged particles in a broad energetic spectrum. Radiation fields of similarly complex nature are, for example, encountered onboard aircraft and in space. Dose equivalent was assessed as a function of depth in quasi tissue-equivalent spheres by means of thermoluminescent dosemeters evaluated according to the high-temperature ratio (HTR) method. The presented experiments were performed both onboard aircraft and the Russian space station Mir. As a result of interaction processes within the phantom body, the incident primary spectrum may be significantly modified with increasing depth. For the radiation field at aviation altitudes we found the maximum of dose equivalent in a depth of 60 mm which conflicts with the 10 mm value recommended by ICRU. Contrary, for the space radiation environment the maximum dose equivalent was found at the surface of the sphere. This suggests that

  18. Applicability of Ambient Dose Equivalent H (d) in Mixed Radiation Fields - A Critical Discussion

    International Nuclear Information System (INIS)

    Vana, R.; Hajek, M.; Bergerm, T.

    2004-01-01

    For purposes of routine radiation protection, it is desirable to characterize the potential irradiation of individuals in terms of a single dose equivalent quantity that would exist in a phantom approximating the human body. The phantom of choice is the ICRU sphere made of 30 cm diameter tissue-equivalent plastic with a density of 1 g/cm3 and a mass composition of 76.2% O, 11.1% C, 10.1% H and 2.6% N. Ambient dose equivalent, H(d), was defined in ICRU report 51 as the dose equivalent that would be produced by an expanded and aligned radiation field at a depth d in the ICRU sphere. The recommended reference depths are 10 mm for strongly penetrating radiation and 0.07 mm for weakly penetrating radiation, respectively. As an operational quantity in radiation protection, H(d) shall serve as a conservative and directly measurable estimate of protection quantities, e.g. effective dose E, which in turn are intended to give an indication of the risk associated with radiation exposure. The situation attains increased complexity in radiation environments being composed of a variety of charged and uncharged particles in a broad energetic spectrum. Radiation fields of similarly complex nature are, for example, encountered onboard aircraft and in space. Dose equivalent was assessed as a function of depth in quasi tissue-equivalent spheres by means of thermoluminescent dosemeters evaluated according to the high-temperature ratio (HTR) method. The presented experiments were performed both onboard aircraft and the Russian space station Mir. As a result of interaction processes within the phantom body, the incident primary spectrum may be significantly modified with increasing depth. For the radiation field at aviation altitudes we found the maximum of dose equivalent in a depth of 60 mm which conflicts with the 10 mm value recommended by ICRU. Contrary, for the space radiation environment the maximum dose equivalent was found at the surface of the sphere. This suggests that skin

  19. Doses from radiation exposure

    CERN Document Server

    Menzel, H G

    2012-01-01

    Practical implementation of the International Commission on Radiological Protection's (ICRP) system of protection requires the availability of appropriate methods and data. The work of Committee 2 is concerned with the development of reference data and methods for the assessment of internal and external radiation exposure of workers and members of the public. This involves the development of reference biokinetic and dosimetric models, reference anatomical models of the human body, and reference anatomical and physiological data. Following ICRP's 2007 Recommendations, Committee 2 has focused on the provision of new reference dose coefficients for external and internal exposure. As well as specifying changes to the radiation and tissue weighting factors used in the calculation of protection quantities, the 2007 Recommendations introduced the use of reference anatomical phantoms based on medical imaging data, requiring explicit sex averaging of male and female organ-equivalent doses in the calculation of effecti...

  20. The alarming problems of confounding equivalence using logistic regression models in the perspective of causal diagrams

    Directory of Open Access Journals (Sweden)

    Yuanyuan Yu

    2017-12-01

    Full Text Available Abstract Background Confounders can produce spurious associations between exposure and outcome in observational studies. For majority of epidemiologists, adjusting for confounders using logistic regression model is their habitual method, though it has some problems in accuracy and precision. It is, therefore, important to highlight the problems of logistic regression and search the alternative method. Methods Four causal diagram models were defined to summarize confounding equivalence. Both theoretical proofs and simulation studies were performed to verify whether conditioning on different confounding equivalence sets had the same bias-reducing potential and then to select the optimum adjusting strategy, in which logistic regression model and inverse probability weighting based marginal structural model (IPW-based-MSM were compared. The “do-calculus” was used to calculate the true causal effect of exposure on outcome, then the bias and standard error were used to evaluate the performances of different strategies. Results Adjusting for different sets of confounding equivalence, as judged by identical Markov boundaries, produced different bias-reducing potential in the logistic regression model. For the sets satisfied G-admissibility, adjusting for the set including all the confounders reduced the equivalent bias to the one containing the parent nodes of the outcome, while the bias after adjusting for the parent nodes of exposure was not equivalent to them. In addition, all causal effect estimations through logistic regression were biased, although the estimation after adjusting for the parent nodes of exposure was nearest to the true causal effect. However, conditioning on different confounding equivalence sets had the same bias-reducing potential under IPW-based-MSM. Compared with logistic regression, the IPW-based-MSM could obtain unbiased causal effect estimation when the adjusted confounders satisfied G-admissibility and the optimal

  1. The alarming problems of confounding equivalence using logistic regression models in the perspective of causal diagrams.

    Science.gov (United States)

    Yu, Yuanyuan; Li, Hongkai; Sun, Xiaoru; Su, Ping; Wang, Tingting; Liu, Yi; Yuan, Zhongshang; Liu, Yanxun; Xue, Fuzhong

    2017-12-28

    Confounders can produce spurious associations between exposure and outcome in observational studies. For majority of epidemiologists, adjusting for confounders using logistic regression model is their habitual method, though it has some problems in accuracy and precision. It is, therefore, important to highlight the problems of logistic regression and search the alternative method. Four causal diagram models were defined to summarize confounding equivalence. Both theoretical proofs and simulation studies were performed to verify whether conditioning on different confounding equivalence sets had the same bias-reducing potential and then to select the optimum adjusting strategy, in which logistic regression model and inverse probability weighting based marginal structural model (IPW-based-MSM) were compared. The "do-calculus" was used to calculate the true causal effect of exposure on outcome, then the bias and standard error were used to evaluate the performances of different strategies. Adjusting for different sets of confounding equivalence, as judged by identical Markov boundaries, produced different bias-reducing potential in the logistic regression model. For the sets satisfied G-admissibility, adjusting for the set including all the confounders reduced the equivalent bias to the one containing the parent nodes of the outcome, while the bias after adjusting for the parent nodes of exposure was not equivalent to them. In addition, all causal effect estimations through logistic regression were biased, although the estimation after adjusting for the parent nodes of exposure was nearest to the true causal effect. However, conditioning on different confounding equivalence sets had the same bias-reducing potential under IPW-based-MSM. Compared with logistic regression, the IPW-based-MSM could obtain unbiased causal effect estimation when the adjusted confounders satisfied G-admissibility and the optimal strategy was to adjust for the parent nodes of outcome, which

  2. The one-dimensional normalised generalised equivalence theory (NGET) for generating equivalent diffusion theory group constants for PWR reflector regions

    International Nuclear Information System (INIS)

    Mueller, E.Z.

    1991-01-01

    An equivalent diffusion theory PWR reflector model is presented, which has as its basis Smith's generalisation of Koebke's Equivalent Theory. This method is an adaptation, in one-dimensional slab geometry, of the Generalised Equivalence Theory (GET). Since the method involves the renormalisation of the GET discontinuity factors at nodal interfaces, it is called the Normalised Generalised Equivalence Theory (NGET) method. The advantages of the NGET method for modelling the ex-core nodes of a PWR are summarized. 23 refs

  3. Uso tradicional de plantas medicinales con acción diurética en el Municipio de Quemado de Güines, Cuba

    Directory of Open Access Journals (Sweden)

    Maykel Pérez Machín

    2011-12-01

    Full Text Available La flora de Cuba es muy rica en plantas medicinales, de las cuales se reportan aproximadamente 179 especies que la población utiliza para fines diuréticos, sin embargo, un gran número de ellas carece de validación experimental de su efecto farmacológico. El presente estudio se realizó con el propósito de documentar la importancia relativa de las especies medicinales más empleadas con fines diuréticos en el municipio de Quemado de Güines de la provincia de Villa Clara, Cuba. Se realizó un estudio etnobotánico en dos comunidades pertenecientes a ese municipio, para lo cual se realizó un muestreo a un total de 85 habitantes, y se aplicó aleatoriamente 80 encuestas a conocedores de plantas y 5 entrevistas entre yerberos y médicos practicantes de medicina tradicional, los cuales nos indicaron las plantas más utilizadas con estos fines en las comunidades estudiadas. La información etnofarmacológica fue registrada mediante la metodología TRAMIL y las especies de interés fueron identificadas y depositadas en el Herbario de la Universidad Central "Marta Abreu" de Las Villas. Los datos se analizaron mediante los índices cuantitativos de valor de uso para cada especie (IVU y el nivel de uso significativo (UST. Este indicador expresa que aquellos usos medicinales que son citados con una frecuencia superior o igual al 20%, por las personas encuestadas pueden considerarse significativos desde el punto de vista de su aceptación cultural y, por lo tanto, merecen su validación científica en Cuba. Se identificaron 26 especies medicinales agrupadas en 19 familias botánicas y se encontraron 10 plantas con un mayor nivel de uso significativo y un mayor IVU. El 53.8% de las plantas reportadas como diuréticas no se han validado experimentalmente en Cuba, el resto de las especies identificadas han sido estudiadas a nivel preclínico, pero aún no está autorizado su empleo como fitomedicamento.Tradicional use of medicinal plants with diuretic

  4. A bicategorical approach to Morita equivalence for von Neumann algebras

    International Nuclear Information System (INIS)

    Brouwer, R. M.

    2003-01-01

    We relate Morita equivalence for von Neumann algebras to the ''Connes fusion'' tensor product between correspondences. In the purely algebraic setting, it is well known that rings are Morita equivalent if they are equivalent objects in a bicategory whose 1-cells are bimodules. We present a similar result for von Neumann algebras. We show that von Neumann algebras form a bicategory, having Connes's correspondences as 1-morphisms, and (bounded) intertwiners as 2-morphisms. Further, we prove that two von Neumann algebras are Morita equivalent iff they are equivalent objects in the bicategory. The proofs make extensive use of the Tomita-Takesaki modular theory

  5. Overview on measures concerning the radiation exposure reduction following events with serious radiological consequences (catalogue of measures) Pt. 2. Background information, theory and examples of use

    International Nuclear Information System (INIS)

    Genkel, Simone; Schnadt, Horst

    2010-01-01

    The report edited by the German Federal Ministry for the Environment, Nature Conservation and Nuclear Safety includes the following chapters: Summary of materials: international nuclear and radiological event scale (INES), nuclear power plants in Europe, significance of the reference nuclide I-131, emergency protection measures, radiation protection measures, contaminated surface waters, contaminated matter disposal, prevention of radiation exposure by inhalation, decision making concerning agriculture and food, radiation protection during disposal procedures. Theoretical fundamentals: decontamination, dose rate, contaminated soils, inhalation dose, contaminated articles, contaminated surface waters, contaminated skin, contamination by ingestion, conversion factors, calculation procedures for appropriate measures. Examples for use of the catalogue of measures.

  6. Theoretical aspects of the equivalence principle

    International Nuclear Information System (INIS)

    Damour, Thibault

    2012-01-01

    We review several theoretical aspects of the equivalence principle (EP). We emphasize the unsatisfactory fact that the EP maintains the absolute character of the coupling constants of physics, while general relativity and its generalizations (Kaluza–Klein, …, string theory) suggest that all absolute structures should be replaced by dynamical entities. We discuss the EP-violation phenomenology of dilaton-like models, which is likely to be dominated by the linear superposition of two effects: a signal proportional to the nuclear Coulomb energy, related to the variation of the fine-structure constant, and a signal proportional to the surface nuclear binding energy, related to the variation of the light quark masses. We recall various theoretical arguments (including a recently proposed anthropic argument) suggesting that the EP be violated at a small, but not unmeasurably small level. This motivates the need for improved tests of the EP. These tests are probing new territories in physics that are related to deep, and mysterious, issues in fundamental physics. (paper)

  7. VERSE - Virtual Equivalent Real-time Simulation

    Science.gov (United States)

    Zheng, Yang; Martin, Bryan J.; Villaume, Nathaniel

    2005-01-01

    Distributed real-time simulations provide important timing validation and hardware in the- loop results for the spacecraft flight software development cycle. Occasionally, the need for higher fidelity modeling and more comprehensive debugging capabilities - combined with a limited amount of computational resources - calls for a non real-time simulation environment that mimics the real-time environment. By creating a non real-time environment that accommodates simulations and flight software designed for a multi-CPU real-time system, we can save development time, cut mission costs, and reduce the likelihood of errors. This paper presents such a solution: Virtual Equivalent Real-time Simulation Environment (VERSE). VERSE turns the real-time operating system RTAI (Real-time Application Interface) into an event driven simulator that runs in virtual real time. Designed to keep the original RTAI architecture as intact as possible, and therefore inheriting RTAI's many capabilities, VERSE was implemented with remarkably little change to the RTAI source code. This small footprint together with use of the same API allows users to easily run the same application in both real-time and virtual time environments. VERSE has been used to build a workstation testbed for NASA's Space Interferometry Mission (SIM PlanetQuest) instrument flight software. With its flexible simulation controls and inexpensive setup and replication costs, VERSE will become an invaluable tool in future mission development.

  8. Challenging a culture of racial equivalence.

    Science.gov (United States)

    Song, Miri

    2014-03-01

    We live at a time when our understandings and conceptualizations of 'racism' are often highly imprecise, broad, and used to describe a wide range of racialized phenomena. In this article, I raise some important questions about how the term racism is used and understood in contemporary British society by drawing on some recent cases of alleged racism in football and politics, many of which have been played out via new media technologies. A broader understanding of racism, through the use of the term 'racialization', has been helpful in articulating a more nuanced and complex understanding of racial incidents, especially of people's (often ambivalent) beliefs and behaviours. However, the growing emphasis upon 'racialization' has led to a conceptualization of racism which increasingly involves multiple perpetrators, victims, and practices without enough consideration of how and why particular interactions and practices constitute racism as such. The trend toward a growing culture of racial equivalence is worrying, as it denudes the idea of racism of its historical basis, severity and power. These frequent and commonplace assertions of racism in the public sphere paradoxically end up trivializing and homogenizing quite different forms of racialized interactions. I conclude that we need to retain the term 'racism', but we need to differentiate more clearly between 'racism' (as an historical and structured system of domination) from the broader notion of 'racialization'. © London School of Economics and Political Science 2014.

  9. Testing the equivalence principle on a trampoline

    Science.gov (United States)

    Reasenberg, Robert D.; Phillips, James D.

    2001-07-01

    We are developing a Galilean test of the equivalence principle in which two pairs of test mass assemblies (TMA) are in free fall in a comoving vacuum chamber for about 0.9 s. The TMA are tossed upward, and the process repeats at 1.2 s intervals. Each TMA carries a solid quartz retroreflector and a payload mass of about one-third of the total TMA mass. The relative vertical motion of the TMA of each pair is monitored by a laser gauge working in an optical cavity formed by the retroreflectors. Single-toss precision of the relative acceleration of a single pair of TMA is 3.5×10-12 g. The project goal of Δg/g = 10-13 can be reached in a single night's run, but repetition with altered configurations will be required to ensure the correction of systematic error to the nominal accuracy level. Because the measurements can be made quickly, we plan to study several pairs of materials.

  10. Testing the equivalence principle on cosmological scales

    Science.gov (United States)

    Bonvin, Camille; Fleury, Pierre

    2018-05-01

    The equivalence principle, that is one of the main pillars of general relativity, is very well tested in the Solar system; however, its validity is more uncertain on cosmological scales, or when dark matter is concerned. This article shows that relativistic effects in the large-scale structure can be used to directly test whether dark matter satisfies Euler's equation, i.e. whether its free fall is characterised by geodesic motion, just like baryons and light. After having proposed a general parametrisation for deviations from Euler's equation, we perform Fisher-matrix forecasts for future surveys like DESI and the SKA, and show that such deviations can be constrained with a precision of order 10%. Deviations from Euler's equation cannot be tested directly with standard methods like redshift-space distortions and gravitational lensing, since these observables are not sensitive to the time component of the metric. Our analysis shows therefore that relativistic effects bring new and complementary constraints to alternative theories of gravity.

  11. A Bayesian equivalency test for two independent binomial proportions.

    Science.gov (United States)

    Kawasaki, Yohei; Shimokawa, Asanao; Yamada, Hiroshi; Miyaoka, Etsuo

    2016-01-01

    In clinical trials, it is often necessary to perform an equivalence study. The equivalence study requires actively denoting equivalence between two different drugs or treatments. Since it is not possible to assert equivalence that is not rejected by a superiority test, statistical methods known as equivalency tests have been suggested. These methods for equivalency tests are based on the frequency framework; however, there are few such methods in the Bayesian framework. Hence, this article proposes a new index that suggests the equivalency of binomial proportions, which is constructed based on the Bayesian framework. In this study, we provide two methods for calculating the index and compare the probabilities that have been calculated by these two calculation methods. Moreover, we apply this index to the results of actual clinical trials to demonstrate the utility of the index.

  12. Assessment of the in vitro dermal irritation potential of cerium, silver, and titanium nanoparticles in a human skin equivalent model

    Science.gov (United States)

    AbstractDermal exposure to metals may res·ult in irritant contact dermatitis. This study examined the potential of metal nanoparticles to elicit irritant contact dermatitis in a human skin equivalent model (HSEM) derived from epidermal keratinocytes. These cultured cells form a m...

  13. General Dynamic Equivalent Modeling of Microgrid Based on Physical Background

    Directory of Open Access Journals (Sweden)

    Changchun Cai

    2015-11-01

    Full Text Available Microgrid is a new power system concept consisting of small-scale distributed energy resources; storage devices and loads. It is necessary to employ a simplified model of microgrid in the simulation of a distribution network integrating large-scale microgrids. Based on the detailed model of the components, an equivalent model of microgrid is proposed in this paper. The equivalent model comprises two parts: namely, equivalent machine component and equivalent static component. Equivalent machine component describes the dynamics of synchronous generator, asynchronous wind turbine and induction motor, equivalent static component describes the dynamics of photovoltaic, storage and static load. The trajectory sensitivities of the equivalent model parameters with respect to the output variables are analyzed. The key parameters that play important roles in the dynamics of the output variables of the equivalent model are identified and included in further parameter estimation. Particle Swarm Optimization (PSO is improved for the parameter estimation of the equivalent model. Simulations are performed in different microgrid operation conditions to evaluate the effectiveness of the equivalent model of microgrid.

  14. Quid de l’utilisation des protéines d’origine végétale en aquaculture ?

    Directory of Open Access Journals (Sweden)

    Burel Christine

    2014-07-01

    Full Text Available Au cours des 30 dernières années, l’aquaculture mondiale n’a cessé de croître pour répondre à la demande croissante de poisson pour la consommation humaine qui ne peut plus être satisfaite par les seules captures de pêche. En conséquence, la demande de matières premières pour les aliments aquacoles augmente, tandis que le volume disponible de farine de poisson, ingrédient traditionnellement majoritaire dans ces aliments, reste stable. Cela a conduit à une substitution des ressources marines par des produits végétaux comme ingrédients pour les aliments pour poissons. La proportion de farine de poisson dans les aliments piscicoles a été réduite d’un tiers et est remplacée par une combinaison de sources protéiques végétales qui fournissent les acides aminés indispensables en quantité suffisante pour répondre aux besoins des poissons. Une large gamme de produits végétaux a été prospectée pour remplacer la farine de poisson. Sur la base de leur composition et de leur disponibilité sur le marché, les produits végétaux les plus utilisés en Europe sont des graines d’oléagineux (soja, colza, tournesol sous forme de tourteaux ou de concentrés protéiques, des protéagineux (lupin, féverole, pois, des céréales (maïs, blé ou des extraits de protéines obtenus à partir de céréales, comme par exemple les glutens. Néanmoins, les études ayant porté sur des taux de substitution très élevés (peu ou pas de farine de poisson ont mis en évidence des verrous physiologiques bien que les régimes contenaient tous les nutriments nécessaires : une baisse de la consommation alimentaire, de l’efficacité alimentaire et du taux de croissance des poissons, ainsi que des modifications métaboliques. Les travaux de recherche doivent être poursuivis afin d’améliorer l’efficacité nutritionnelle des produits végétaux via une réduction de leurs facteurs antinutritionnels et des toxines qu’ils contiennent

  15. Türkiye’de Denizcilik Eğitiminin Geleceğine Yönelik Nicel Bir Çalışma Örneği

    Directory of Open Access Journals (Sweden)

    Ünal ÖZDEMİR

    2017-07-01

    Full Text Available Bu çalışma ile ülkemizde yükseköğretim kurumuna (YÖK bağlı denizcilik eğitimi veren lisans düzeyindeki bölümlerde yer alan öğretim üyelerine yönelik kantitatif bir araştırma yapılması amaçlanmıştır. Lisans düzeyinde denizcilik eğitimi veren deniz ulaştırma işletme ve gemi makinaları işletme mühendisliği bölümleri kapsamında yer alan öğretim üyeleri çalışmanın ana kapsamını oluşturmaktadır. Bu bölümlerin eğitim-öğretim faaliyetlerini yerine getirebilmeleri için gerekliliklerini sağlama konusunda yaşanan sorunların, yeni kurulan fakülte ve yüksekokul sayılarının artması ile birlikte daha da çarpıcı boyuta geleceği tahmin edilmektedir. Çalışmada probleme neden olan etkenler kantitatif teknikler yardımı ile incelenmiş ve soruna yönelik çözüm önerileri sunulmaya çalışılmıştır. Probleme neden olan çeşitli etkenler bir araya getirilerek, bu etkenlerin birbirleri ile olan ilişkileri ve önem dereceleri bulanık AHP (Fuzzy Analytic Hierarchy Process ve soruna çözüm sunabilecek çözüm önerileri arasında da bir değerlendirme yapabilmesi adına bulanık TOPSIS (Fuzzy Technique for Order Performance by Similarity to Ideal Solution yönteminin ele alındığı bir model yaklaşımı kullanılmıştır. Çalışma sonuçlarına göre öğretim üyesi sayısının yeterli sayıda olmayışının temel nedenlerinden bazıları sırasıyla; “akademisyen ücretlerinin düşüklüğü”, “denizde çalışanlar için yüksek ücret imkânı”, “üniversiteler tarafından yeteri sayıda akademik kadronun açılmaması” olarak tespit edilmiştir. Bu soruna çözüm getirebilecek en önemli alternatiflerden bazıları ise; “akademisyenlik mesleğine olan ilginin arttırılması, özendirilmesi ve öğrencilerin bu alana yönlendirilmesi”, “YÖK’ün istemiş olduğu gerekliliklerin denizcilik eğitimi veren kurumlar için farklı kategoride d

  16. Minor sources of miner exposure

    International Nuclear Information System (INIS)

    Strong, J.C.; Green, N.; Brown, K.; O'Riordan, M.C.

    1983-01-01

    The sources of radiation exposure to miners in non-coal mines in addition to radon daughters are thoron daughters in mine air, long-lived radionuclides in mine dust and gamma radiation from the local rocks. A crude estimate of the total annual effective dose equivalent from these minor sources is 2 - 5 mSv which is of secondary importance compared to the dose from radon daughters. (UK)

  17. Dose sculpting with generalized equivalent uniform dose

    International Nuclear Information System (INIS)

    Wu Qiuwen; Djajaputra, David; Liu, Helen H.; Dong Lei; Mohan, Radhe; Wu, Yan

    2005-01-01

    With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this study was to investigate the effectiveness of gEUD optimization to fine tune the dose distributions of IMRT plans. We analyzed the effect of gEUD-based optimization parameters on plan quality. The objective was to determine whether dose distribution to selected structures could be improved using gEUD optimization without adversely altering the doses delivered to other structures, as in sculpting. We hypothesized that by carefully defining gEUD parameters (EUD 0 and n) based on the current dose distributions, the optimization system could be instructed to search for alternative solutions in the neighborhood, and we could maintain the dose distributions for structures already satisfactory and improve dose for structures that need enhancement. We started with an already acceptable IMRT plan optimized with any objective function. The dose distribution was analyzed first. For structures that dose should not be changed, a higher value of n was used and EUD 0 was set slightly higher/lower than the EUD value at the current dose distribution for critical structures/targets. For structures that needed improvement in dose, a higher to medium value of n was used, and EUD 0 was set to the EUD value or slightly lower/higher for the critical structure/target at the current dose distribution. We evaluated this method in one clinical case each of head and neck, lung and prostate cancer. Dose volume histograms, isodose distributions, and relevant tolerance doses for critical structures were used for the assessment. We found that by adjusting gEUD optimization parameters, the dose distribution could be improved with only a few iterations. A larger value of n could lead to

  18. The radiobiology of boron neutron capture therapy: Are ''photon-equivalent'' doses really photon-equivalent?

    International Nuclear Information System (INIS)

    Coderre, J.A.; Diaz, A.Z.; Ma, R.

    2001-01-01

    Boron neutron capture therapy (BNCT) produces a mixture of radiation dose components. The high-linear energy transfer (LET) particles are more damaging in tissue than equal doses of low-LET radiation. Each of the high-LET components can multiplied by an experimentally determined factor to adjust for the increased biological effectiveness and the resulting sum expressed in photon-equivalent units (Gy-Eq). BNCT doses in photon-equivalent units are based on a number of assumptions. It may be possible to test the validity of these assumptions and the accuracy of the calculated BNCT doses by 1) comparing the effects of BNCT in other animal or biological models where the effects of photon radiation are known, or 2) if there are endpoints reached in the BNCT dose escalation clinical trials that can be related to the known response to photons of the tissue in question. The calculated Gy-Eq BNCT doses delivered to dogs and to humans with BPA and the epithermal neutron beam of the Brookhaven Medical Research Reactor were compared to expected responses to photon irradiation. The data indicate that Gy-Eq doses in brain may be underestimated. Doses to skin are consistent with the expected response to photons. Gy-Eq doses to tumor are significantly overestimated. A model system of cells in culture irradiated at various depths in a lucite phantom using the epithermal beam is under development. Preliminary data indicate that this approach can be used to detect differences in the relative biological effectiveness of the beam. The rat 9L gliosarcoma cell survival data was converted to photon-equivalent doses using the same factors assumed in the clinical studies. The results superimposed on the survival curve derived from irradiation with Cs-137 photons indicating the potential utility of this model system. (author)

  19. Americium-241 use of measurement lead equivalent thickness for medical x-ray room: A review

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Husaini Saleh; Abd Aziz Mhd Ramli; Muhammad Jamal Md Isa; Mohd Firdaus Abd Rahman; Zainal Jamaluddin

    2010-01-01

    Lead equivalent thickness measurement of a shielding material in diagnostic radiology is very important to ensure that requirements for the purpose of radiation protection of patients, employees and the public are met. The Malaysian Ministry of Health (MOH) has established that the irradiation room must have sufficient shielding thickness, for example for general radiography it must be at least equal to 2.0 mm of Pb, for panoramic dental radiography at least equal to 1.5 mm of Pb and for mammography should be a minimum of 1.0 mm of Pb. This paper presents a technique using americium-241 source to test and verify the integrity of the shielding thickness in term of lead equivalent for X-ray room at health centres. Results of measurement of 30 irradiation rooms conducted from 2009 to mid 2010 were analyzed for this presentation. Technical comparison of the attenuation of gamma rays from Am-241 source through the walls of the irradiation room and pieces of lead were used to assess the lead equivalent thickness of the walls. Results showed that 96.7 % of the irradiation rooms tested meet the requirements of the Ministry of Health and is suitable for the installation of the intended diagnostic X-ray apparatus. Some specific positions such as door knobs and locks, electrical plug sockets were identified with potential to not met the required lead equivalent thickness hence may contribute to higher radiation exposure to workers and the public. (author)

  20. Dynamic equivalence relation on the fuzzy measure algebras

    Directory of Open Access Journals (Sweden)

    Roya Ghasemkhani

    2017-04-01

    Full Text Available The main goal of the present paper is to extend classical results from the measure theory and dynamical systems to the fuzzy subset setting. In this paper, the notion of  dynamic equivalence relation is introduced and then it is proved that this relation is an equivalence relation. Also, a new metric on the collection of all equivalence classes is introduced and it is proved that this metric is complete.

  1. Equivalence principle violations and couplings of a light dilaton

    International Nuclear Information System (INIS)

    Damour, Thibault; Donoghue, John F.

    2010-01-01

    We consider possible violations of the equivalence principle through the exchange of a light 'dilaton-like' scalar field. Using recent work on the quark-mass dependence of nuclear binding, we find that the dilaton-quark-mass coupling induces significant equivalence-principle-violating effects varying like the inverse cubic root of the atomic number - A -1/3 . We provide a general parametrization of the scalar couplings, but argue that two parameters are likely to dominate the equivalence-principle phenomenology. We indicate the implications of this framework for comparing the sensitivities of current and planned experimental tests of the equivalence principle.

  2. Equivalent Sensor Radiance Generation and Remote Sensing from Model Parameters. Part 1; Equivalent Sensor Radiance Formulation

    Science.gov (United States)

    Wind, Galina; DaSilva, Arlindo M.; Norris, Peter M.; Platnick, Steven E.

    2013-01-01

    In this paper we describe a general procedure for calculating equivalent sensor radiances from variables output from a global atmospheric forecast model. In order to take proper account of the discrepancies between model resolution and sensor footprint the algorithm takes explicit account of the model subgrid variability, in particular its description of the probably density function of total water (vapor and cloud condensate.) The equivalent sensor radiances are then substituted into an operational remote sensing algorithm processing chain to produce a variety of remote sensing products that would normally be produced from actual sensor output. This output can then be used for a wide variety of purposes such as model parameter verification, remote sensing algorithm validation, testing of new retrieval methods and future sensor studies. We show a specific implementation using the GEOS-5 model, the MODIS instrument and the MODIS Adaptive Processing System (MODAPS) Data Collection 5.1 operational remote sensing cloud algorithm processing chain (including the cloud mask, cloud top properties and cloud optical and microphysical properties products.) We focus on clouds and cloud/aerosol interactions, because they are very important to model development and improvement.

  3. Estimation of equivalent dose on the ends of hemodynamic physicians during neurological procedures

    International Nuclear Information System (INIS)

    Squair, Peterson L.; Souza, Luiz C. de; Oliveira, Paulo Marcio C. de

    2005-01-01

    The estimation of doses in the hands of physicists during hemodynamic procedures is important to verify the application of radiation protection related to the optimization and limit of dose, principles required by the Portaria 453/98 of Ministry of Health/ANVISA, Brazil. It was checked the levels of exposure of the hands of doctors during the use of the equipment in hemodynamic neurological procedures through dosimetric rings with thermoluminescent dosemeters detectors of LiF: Mg, Ti (TLD-100), calibrated in personal Dose equivalent HP (0.07). The average equivalent dose in the end obtained was 41.12. μSv per scan with an expanded uncertainty of 20% for k = 2. This value is relative to the hemodynamic Neurology procedure using radiological protection procedures accessible to minimize the dose

  4. The monetary value of the collective dose equivalent unit (person-rem)

    International Nuclear Information System (INIS)

    Rodgers, Reginald C.

    1978-01-01

    In the design and operation of nuclear power reactor facilities, it is recommended that radiation exposures to the workers and the general public be kept as 'low as reasonably achievable' (ALARA). In the process of implementing this principle cost-benefit evaluations are part of the decision making process. For this reason a monetary value has to be assigned to the collective dose equivalent unit (person-rem). The various factors such as medical health care, societal penalty and manpower replacement/saving are essential ingredients to determine a monetary value for the person-rem. These factors and their dependence on the level of risk (or exposure level) are evaluated. Monetary values of well under $100 are determined for the public dose equivalent unit. The occupational worker person-rem value is determined to be in the range of $500 to about $5000 depending on the exposure level and the type of worker and his affiliation, i.e., temporary or permanent. A discussion of the variability and the range of the monetary values will be presented. (author)

  5. Development of solid water-equivalent radioactive certified reference materials

    International Nuclear Information System (INIS)

    Finke, E.; Greupner, H.; Groche, K.; Rittwag, R.; Geske, G.

    1991-01-01

    This paper presents a brief description of the development of solid water-equivalent beta volume radioactive certified reference materials. These certified reference materials were prepared for the beta fission nuclides 90 Sr/ 90 Y, 137 Cs, 147 Pm and 204 Tl. Comparative measurements of liquid and solid water-equivalent beta volume radioactive certified reference materials are discussed. (author)

  6. Equivalence of quantum states under local unitary transformations

    International Nuclear Information System (INIS)

    Fei Shaoming; Jing Naihuan

    2005-01-01

    In terms of the analysis of fixed point subgroup and tensor decomposability of certain matrices, we study the equivalence of quantum bipartite mixed states under local unitary transformations. For non-degenerate case an operational criterion for the equivalence of two such mixed bipartite states under local unitary transformations is presented

  7. 40 CFR 133.105 - Treatment equivalent to secondary treatment.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Treatment equivalent to secondary treatment. 133.105 Section 133.105 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS SECONDARY TREATMENT REGULATION § 133.105 Treatment equivalent to secondary treatment...

  8. Microcystin-LR equivalent concentrations in fish tissue during a ...

    African Journals Online (AJOL)

    The effects of a decomposing cyanobacteria bloom on water quality and the accumulation of microcystin-LR equivalent toxin in fish at Loskop Dam were studied in May 2012. Enzyme-linked immunosorbent assay [ELISA] was used to confirm the presence of microcystin-LR equivalent in the water and to determine the ...

  9. Decompositional equivalence: A fundamental symmetry underlying quantum theory

    OpenAIRE

    Fields, Chris

    2014-01-01

    Decompositional equivalence is the principle that there is no preferred decomposition of the universe into subsystems. It is shown here, by using simple thought experiments, that quantum theory follows from decompositional equivalence together with Landauer's principle. This demonstration raises within physics a question previously left to psychology: how do human - or any - observers agree about what constitutes a "system of interest"?

  10. Preparation of A-150 tissue-equivalent plastic films

    International Nuclear Information System (INIS)

    Saion, E.B.; Shaari, A.H.; Watt, D.E.

    1992-01-01

    A-150 tissue-equivalent (TE) plastic is widely used as a wall material for tissue-equivalent proportional counters (TEPCS) used in experimental microdosimetry. The objective of this note is to give a technical account of how A-150 TE plastic film can be fabricated in the laboratory from commercially available A-150 TE plastic. (author)

  11. Equivalence of several Chern-Simons matter models

    International Nuclear Information System (INIS)

    Chen, W.; Itoi, C.

    1994-01-01

    Chern-Simons (CS) coupling characterizes not only statistics, but also spin and scaling dimension of matter fields. We demonstrate spin transmutation in relativistic CS matter theory, and moreover show equivalence of several models. We study the CS vector model in some detail, which provides a consistent check to the assertion of the equivalence

  12. 29 CFR 4.170 - Furnishing fringe benefits or equivalents.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Furnishing fringe benefits or equivalents. 4.170 Section 4... Standards Compliance with Compensation Standards § 4.170 Furnishing fringe benefits or equivalents. (a) General. Fringe benefits required under the Act shall be furnished, separate from and in addition to the...

  13. Theory of Covariance Equivalent ARMAV Models of Civil Engineering Structures

    DEFF Research Database (Denmark)

    Andersen, P.; Brincker, Rune; Kirkegaard, Poul Henning

    1996-01-01

    In this paper the theoretical background for using covariance equivalent ARMAV models in modal analysis is discussed. It is shown how to obtain a covariance equivalent ARMA model for a univariate linear second order continous-time system excited by Gaussian white noise. This result is generalized...

  14. Theory of Covariance Equivalent ARMAV Models of Civil Engineering Structures

    DEFF Research Database (Denmark)

    Andersen, P.; Brincker, Rune; Kirkegaard, Poul Henning

    In this paper the theoretical background for using covariance equivalent ARMAV models in modal analysis is discussed. It is shown how to obtain a covariance equivalent ARMA model for a univariate linear second order continuous-time system excited by Gaussian white noise. This result is generalize...

  15. Graphene-based THz modulator analyzed by equivalent circuit model

    DEFF Research Database (Denmark)

    Xiao, Binggang; Chen, Jing; Xie, Zhiyi

    2016-01-01

    A terahertz (THz) modulator based on graphene is proposed and analysed by use of equivalent transmission line of a homogeneous mediumand the local anisotropic model of the graphene conductivity. The result calculated by the equivalent circuit is consistent with that obtained byFresnel transfer...

  16. The lexicographical handling of grammatical equivalence: the case ...

    African Journals Online (AJOL)

    Lexicographers compiling translating dictionaries are not exclusively concerned with semantic equivalence when selecting translating equivalents for lemmata, but often include also grammatical information in illustrative examples when the lexical item to be translated does not have an exact grammatical counterpart in the ...

  17. 30 CFR 90.206 - Approved sampling devices; equivalent concentrations.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; equivalent... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.206 Approved sampling devices; equivalent...

  18. Teaching Brain-Behavior Relations Economically with Stimulus Equivalence Technology

    Science.gov (United States)

    Fienup, Daniel M.; Covey, Daniel P.; Critchfield, Thomas S.

    2010-01-01

    Instructional interventions based on stimulus equivalence provide learners with the opportunity to acquire skills that are not directly taught, thereby improving the efficiency of instructional efforts. The present report describes a study in which equivalence-based instruction was used to teach college students facts regarding brain anatomy and…

  19. Foundations of gravitation theory: the principle of equivalence

    International Nuclear Information System (INIS)

    Haugan, M.P.

    1978-01-01

    A new framework is presented within which to discuss the principle of equivalence and its experimental tests. The framework incorporates a special structure imposed on the equivalence principle by the principle of energy conservation. This structure includes relations among the conceptual components of the equivalence principle as well as quantitative relations among the outcomes of its experimental tests. One of the most striking new results obtained through use of this framework is a connection between the breakdown of local Lorentz invariance and the breakdown of the principle that all bodies fall with the same acceleration in a gravitational field. An extensive discussion of experimental tests of the equivalence principle and their significance is also presented. Within the above framework, theory-independent analyses of a broad range of equivalence principle tests are possible. Gravitational redshift experiments. Doppler-shift experiments, the Turner-Hill and Hughes-Drever experiments, and a number of solar-system tests of gravitation theories are analyzed. Application of the techniques of theoretical nuclear physics to the quantitative interpretation of equivalence principle tests using laboratory materials of different composition yields a number of important results. It is found that current Eotvos experiments significantly demonstrate the compatibility of the weak interactions with the equivalence principle. It is also shown that the Hughes-Drever experiment is the most precise test of local Lorentz invariance yet performed. The work leads to a strong, tightly knit empirical basis for the principle of equivalence, the central pillar of the foundations of gravitation theory

  20. Comparison of adult and child radiation equivalent doses from 2 dental cone-beam computed tomography units.

    Science.gov (United States)

    Al Najjar, Anas; Colosi, Dan; Dauer, Lawrence T; Prins, Robert; Patchell, Gayle; Branets, Iryna; Goren, Arthur D; Faber, Richard D

    2013-06-01

    With the advent of cone-beam computed tomography (CBCT) scans, there has been a transition toward these scans' replacing traditional radiographs for orthodontic diagnosis and treatment planning. Children represent a significant proportion of orthodontic patients. Similar CBCT exposure settings are predicted to result in higher equivalent doses to the head and neck organs in children than in adults. The purpose of this study was to measure the difference in equivalent organ doses from different scanners under similar settings in children compared with adults. Two phantom heads were used, representing a 33-year-old woman and a 5-year-old boy. Optically stimulated dosimeters were placed at 8 key head and neck organs, and equivalent doses to these organs were calculated after scanning. The manufacturers' predefined exposure settings were used. One scanner had a pediatric preset option; the other did not. Scanning the child's phantom head with the adult settings resulted in significantly higher equivalent radiation doses to children compared with adults, ranging from a 117% average ratio of equivalent dose to 341%. Readings at the cervical spine level were decreased significantly, down to 30% of the adult equivalent dose. When the pediatric preset was used for the scans, there was a decrease in the ratio of equivalent dose to the child mandible and thyroid. CBCT scans with adult settings on both phantom heads resulted in higher radiation doses to the head and neck organs in the child compared with the adult. In practice, this might result in excessive radiation to children scanned with default adult settings. Collimation should be used when possible to reduce the radiation dose to the patient. While CBCT scans offer a valuable tool, use of CBCT scans should be justified on a specific case-by-case basis. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  1. Calculation simulation of equivalent irradiation swelling for dispersion nuclear fuel

    International Nuclear Information System (INIS)

    Cai Wei; Zhao Yunmei; Gong Xin; Ding Shurong; Huo Yongzhong

    2015-01-01

    The dispersion nuclear fuel was regarded as a kind of special particle composites. Assuming that the fuel particles are periodically distributed in the dispersion nuclear fuel meat, the finite element model to calculate its equivalent irradiation swelling was developed with the method of computational micro-mechanics. Considering irradiation swelling in the fuel particles and the irradiation hardening effect in the metal matrix, the stress update algorithms were established respectively for the fuel particles and metal matrix. The corresponding user subroutines were programmed, and the finite element simulation of equivalent irradiation swelling for the fuel meat was performed in Abaqus. The effects of the particle size and volume fraction on the equivalent irradiation swelling were investigated, and the fitting formula of equivalent irradiation swelling was obtained. The results indicate that the main factors to influence equivalent irradiation swelling of the fuel meat are the irradiation swelling and volume fraction of fuel particles. (authors)

  2. On identifying name equivalences in digital libraries. Name equivalence, Surname matching, Author identification, Databases

    Directory of Open Access Journals (Sweden)

    Dror G. Feitelson

    2004-01-01

    Full Text Available The services provided by digital libraries can be much improved by correctly identifying variants of the same name. For example, this will allow for better retrieval of all the works by a certain author. We focus on variants caused by abbreviations of first names, and show that significant achievements are possible by simple lexical analysis and comparison of names. This is done in two steps: first a pairwise matching of names is performed, and then these are used to find cliques of equivalent names. However, these steps can each be performed in a variety of ways. We therefore conduct an experimental analysis using two real datasets to find which approaches actually work well in practice. Interestingly, this depends on the size of the repository, as larger repositories may have many more similar names.

  3. XRD, lead equivalent and UV-VIS properties study of Ce and Pr lead silicate glasses

    International Nuclear Information System (INIS)

    Alias, Nor Hayati; Abdullah, Wan Shafie Wan; Isa, Norriza Mohd; Isa, Muhammad Jamal Md; Zali, Nurazila Mat; Abdullah, Nuhaslinda Ee; Muhammad, Azali

    2014-01-01

    In this work, Cerium (Ce) and Praseodymium (Pr) containing lead silicate glasses were produced with 2 different molar ratios low (0.2 wt%) and high (0.4wt%). These types of glasses can satisfy the characteristics required for radiation shielding glasses and minimize the lead composition in glass. The radiation shielding properties of the synthesized glasses is explained in the form of lead equivalent study. The XRD diffraction and UV-VIS analysis were performed to observe the structural changes of the synthesis glasses at 1.5 Gy gamma radiation exposures

  4. The performance of low pressure tissue-equivalent chambers and a new method for parameterising the dose equivalent

    International Nuclear Information System (INIS)

    Eisen, Y.

    1986-01-01

    The performance of Rossi-type spherical tissue-equivalent chambers with equivalent diameters between 0.5 μm and 2 μm was tested experimentally using monoenergetic and polyenergetic neutron sources in the energy region of 10 keV to 14.5 MeV. In agreement with theoretical predictions both chambers failed to provide LET information at low neutron energies. A dose equivalent algorithm was derived that utilises the event distribution but does not attempt to correlate event size with LET. The algorithm was predicted theoretically and confirmed by experiment. The algorithm that was developed determines the neutron dose equivalent, from the data of the 0.5 μm chamber, to better than +-20% over the energy range of 30 keV to 14.5 MeV. The same algorithm also determines the dose equivalent from the data of the 2 μm chamber to better than +-20% over the energy range of 60 keV to 14.5 MeV. The efficiency of the chambers is 33 counts per μSv, or equivalently about 10 counts s -1 per mSv.h -1 . This efficiency enables the measurement of dose equivalent rates above 1 mSv.h -1 for an integration period of 3 s. Integrated dose equivalents can be measured as low as 1 μSv. (author)

  5. Mathematical simulation of biologically equivalent doses for LDR-HDR

    International Nuclear Information System (INIS)

    Slosarek, K.; Zajusz, A.

    1996-01-01

    Based on the LQ model examples of biologically equivalent doses LDR, HDR and external beams were calculated. The biologically equivalent doses for LDR were calculated by appending to the LQ model the corrector for the time of repair of radiation sublethal damages. For radiation continuously delivered at a low dose rate the influence of sublethal damage repair time changes on biologically equivalent doses were analysed. For fractionated treatment with high dose rate the biologically equivalent doses were calculated by adding to the LQ model the formula of accelerated repopulation. For total biologically equivalent dose calculation for combine LDR-HDR-Tele irradiation examples are presented with the use of different parameters of the time of repair of sublethal damages and accelerated repopulation. The calculations performed show, that the same biologically equivalent doses can be obtained for different parameters of cell kinetics changes during radiation treatment. It also shows, that during biologically equivalent dose calculations for different radiotherapy schedules, ignorance of cell kinetics parameters can lead to relevant errors

  6. Sources of radiation exposure - an overview

    International Nuclear Information System (INIS)

    Mason, G.C.

    1990-01-01

    Sources of radiation exposure are reviewed from the perspective of mining and milling of radioactive ores in Australia. The major sources of occupational and public exposure are identified and described, and exposures from mining and milling operations are discussed in the context of natural radiation sources and other sources arising from human activities. Most radiation exposure of humans comes from natural sources. About 80% of the world average of the effective dose equivalents received by individual people arises from natural radiation, with a further 15-20% coming from medical exposures*. Exposures results from human activities, such as mining and milling of radioactive ores, nuclear power generation, fallout from nuclear weapons testing and non-medical use of radioisotopes and X-rays, add less than 1% to the total. 9 refs., 4 tabs., 10 figs

  7. Application of maximum radiation exposure values and monitoring of radiation exposure

    International Nuclear Information System (INIS)

    1993-01-01

    According to the Section 32 of the Radiation Act (592/91) the Finnish Centre for Radiation and Nuclear Safety gives instructions concerning the monitoring of the radiation exposure and the application of the dose limits in Finland. The principles to be applied to calculating the equivalent and the effective doses are presented in the guide. Also the detailed instructions on the application of the maximum exposure values for the radiation work and for the natural radiation as well as the instructions on the monitoring of the exposures are given. Quantities and units for assessing radiation exposure are presented in the appendix of the guide

  8. Modelling of dynamic equivalents in electric power grids

    International Nuclear Information System (INIS)

    Craciun, Diana Iuliana

    2010-01-01

    In a first part, this research thesis proposes a description of the context and new constraints of electric grids: architecture, decentralized production with the impact of distributed energy resource systems, dynamic simulation, and interest of equivalent models. Then, the author discusses the modelling of the different components of electric grids: synchronous and asynchronous machines, distributed energy resource with power electronic interface, loading models. She addresses the techniques of reduction of electric grid models: conventional reduction methods, dynamic equivalence methods using non linear approaches or evolutionary algorithm-based methods of assessment of parameters. This last approach is then developed and implemented, and a new method of computation of dynamic equivalents is described

  9. Asymptotically double lacunry equivalent sequences defined by Orlicz functions

    Directory of Open Access Journals (Sweden)

    Ayhan Esi

    2014-04-01

    Full Text Available This paper presents the following definition which is natural combition of the definition for asymptotically equivalent and Orlicz function. The two nonnegative double sequences x=(x_{k,l} and y=(y_{k,l} are said to be M-asymptotically double equivalent to multiple L provided that for every ε>0, P-lim_{k,l}M(((|((x_{k,l}/(y_{k,l}-L|/ρ=0, for some ρ>0, (denoted by x∽y and simply M-asymptotically double equivalent if L=1. Also we give some new concepts related to this definition and some inclusion theorems.

  10. Calculation of committed dose equivalent from intake of tritiated water

    International Nuclear Information System (INIS)

    Law, D.V.

    1978-08-01

    A new computerized method of calculating the committed dose equivalent from the intake of tritiated water at Harwell is described in this report. The computer program has been designed to deal with a variety of intake patterns and urine sampling schemes, as well as to produce committed dose equivalents corresponding to any periods for which individual monitoring for external radiation is undertaken. Details of retrospective doses are added semi-automatically to the Radiation Dose Records and committed dose equivalents are retained on a separate file. (author)

  11. The Application of Equivalence Theory to Advertising Translation

    Institute of Scientific and Technical Information of China (English)

    张颖

    2017-01-01

    Through analyzing equivalence theory, the author tries to find a solution to the problems arising in the process of ad?vertising translation. These problems include cultural diversity, language diversity and special requirement of advertisement. The author declares that Nida''s functional equivalence is one of the most appropriate theories to deal with these problems. In this pa?per, the author introduces the principles of advertising translation and culture divergences in advertising translation, and then gives some advertising translation practices to explain and analyze how to create good advertising translation by using functional equivalence. At last, the author introduces some strategies in advertising translation.

  12. Spaces of homotopy self-equivalences a survey

    CERN Document Server

    Rutter, John W

    1997-01-01

    This survey covers groups of homotopy self-equivalence classes of topological spaces, and the homotopy type of spaces of homotopy self-equivalences. For manifolds, the full group of equivalences and the mapping class group are compared, as are the corresponding spaces. Included are methods of calculation, numerous calculations, finite generation results, Whitehead torsion and other areas. Some 330 references are given. The book assumes familiarity with cell complexes, homology and homotopy. Graduate students and established researchers can use it for learning, for reference, and to determine the current state of knowledge.

  13. Apparent violation of the principle of equivalence and Killing horizons

    International Nuclear Information System (INIS)

    Zimmerman, R.L.; Farhoosh, H.; Oregon Univ., Eugene

    1980-01-01

    By means of the principle of equivalence it is deduced that the qualitative behavior of the Schwarzschild horizon about a uniformly accelerating particle. This result is confirmed for an exact solution of a uniformly accelerating object in the limit of small accelerations. For large accelerations the Schwarzschild horizon appears to violate the qualitative behavior established via the principle of equivalence. When similar arguments are extended to an observable such as the red shift between two observers, there is no departure from the results expected from the principle of equivalence. The resolution of the paradox is brought about by a compensating effect due to the Rindler horizon. (author)

  14. Photoprotection by pistachio bioactives in a 3-dimensional human skin equivalent tissue model.

    Science.gov (United States)

    Chen, C-Y Oliver; Smith, Avi; Liu, Yuntao; Du, Peng; Blumberg, Jeffrey B; Garlick, Jonathan

    2017-09-01

    Reactive oxygen species (ROS) generated during ultraviolet (UV) light exposure can induce skin damage and aging. Antioxidants can provide protection against oxidative injury to skin via "quenching" ROS. Using a validated 3-dimensional (3D) human skin equivalent (HSE) tissue model that closely mimics human skin, we examined whether pistachio antioxidants could protect HSE against UVA-induced damage. Lutein and γ-tocopherol are the predominant lipophilic antioxidants in pistachios; treatment with these compounds prior to UVA exposure protected against morphological changes to the epithelial and connective tissue compartments of HSE. Pistachio antioxidants preserved overall skin thickness and organization, as well as fibroblast morphology, in HSE exposed to UVA irradiation. However, this protection was not substantiated by the analysis of the proliferation of keratinocytes and apoptosis of fibroblasts. Additional studies are warranted to elucidate the basis of these discordant results and extend research into the potential role of pistachio bioactives promoting skin health.

  15. Radiation exposure of the crew in commercial air traffic

    International Nuclear Information System (INIS)

    Antic, D.; Markovic, P.; Petrovic, Z.

    1993-01-01

    The routine radiation exposure of the crews in Yugoslav Airlines (JAT) has been studied and some previous results are presented. The flights of four selected groups of pilots (four aircraft types) have been studied during one year. Annual exposures and dose equivalents are presented. Some additional results and discussions are given. (1 fig., 4 tabs.)

  16. The neutron dose equivalent around high energy medical electron linear accelerators

    Directory of Open Access Journals (Sweden)

    Poje Marina

    2014-01-01

    Full Text Available The measurement of neutron dose equivalent was made in four dual energy linear accelerator rooms. Two of the rooms were reconstructed after decommissioning of 60Co units, so the main limitation was the space. The measurements were performed by a nuclear track etched detectors LR-115 associated with the converter (radiator that consist of 10B and with the active neutron detector Thermo BIOREM FHT 742. The detectors were set at several locations to evaluate the neutron ambient dose equivalent and/or neutron dose rate to which medical personnel could be exposed. Also, the neutron dose dependence on collimator aperture was analyzed. The obtained neutron dose rates outside the accelerator rooms were several times smaller than the neutron dose rates inside the accelerator rooms. Nevertheless, the measured neutron dose equivalent was not negligible from the aspect of the personal dosimetry with almost 2 mSv a year per person in the areas occupied by staff (conservative estimation. In rooms with 15 MV accelerators, the neutron exposure to the personnel was significantly lower than in the rooms having 18 MV accelerators installed. It was even more pronounced in the room reconstructed after the 60Co decommissioning. This study confirms that shielding from the neutron radiation should be considered when building vaults for high energy linear accelerators, especially when the space constraints exist.

  17. Deciding Type Equivalence in a Language with Singleton Kinds

    National Research Council Canada - National Science Library

    Stone, Christopher

    1999-01-01

    ...: S(A) is the kind of all types provably equivalent to the type A. Singletons are interesting because they provide a very general form of definitions for type variables and allow fine-grained control of type computations...

  18. Lipschitz equivalence of self-similar sets with touching structures

    International Nuclear Information System (INIS)

    Ruan, Huo-Jun; Wang, Yang; Xi, Li-Feng

    2014-01-01

    Lipschitz equivalence of self-similar sets is an important area in the study of fractal geometry. It is known that two dust-like self-similar sets with the same contraction ratios are always Lipschitz equivalent. However, when self-similar sets have touching structures the problem of Lipschitz equivalence becomes much more challenging and intriguing at the same time. So far, all the known results only cover self-similar sets in R with no more than three branches. In this study we establish results for the Lipschitz equivalence of self-similar sets with touching structures in R with arbitrarily many branches. Key to our study is the introduction of a geometric condition for self-similar sets called substitutable. (paper)

  19. Approved Drug Products with Therapuetic Equivalence Evaluations (Orange Book)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The publication Approved Drug Products with Therapeutic Equivalence Evaluations (the List, commonly known as the Orange Book) identifies drug products approved on...

  20. ESA GlobSnow Snow Water Equivalent (SWE)

    Data.gov (United States)

    National Aeronautics and Space Administration — The European Space Agency (ESA) Global Snow Monitoring for Climate Research (GlobSnow) snow water equivalent (SWE) v2.0 data record contains snow information derived...