WorldWideScience

Sample records for equipment quality control

  1. Electronic quality control on dental x-rays equipment

    International Nuclear Information System (INIS)

    Pomares C, Martin

    1996-09-01

    A brief description of dental x-ray equipment is done. The non-invasive quality control is treated as than the responsibilities from the dentists to the patient and the equipment. A propose for quality control for dental x-ray equipment, film and developer is include

  2. Exposure parameters in fluoroscopy equipment. Quality control

    International Nuclear Information System (INIS)

    Alonso, M.; Castaneda, M.J.; Matorras, P.; Diaz-Caneja, N.; Gutierrez, I.

    1992-01-01

    Within the quality control program in Diagnostic Radiology currently being undertaken at the 'Marques de Valdecilla' University Hospital, the corresponding specification and procedure prototypes for the control of conventional radioscopy equipment have been elaborated and applied. This paper presents the values proposed in the specifications and those obtained for the following radioscopy equipment parameters: reference kerma, and its reproducibility, kerma linearity, maximum kerma at the skin, and total filtration. The results obtained indicate that the equipment studied could comply with specified requirements if a Maintenance Program were to be implemented in coordination with the Quality Control Program. (author)

  3. Ways to control quality of electric equipment in the coal industry

    Energy Technology Data Exchange (ETDEWEB)

    Shipilov, A.D.; Nabokov, E.P.

    1982-01-01

    A structure is proposed for organization in the coal industry of a permanent service for controlling quality of electrical engineering equipment. A form was developed for introduction of recommendations to improve quality. Methods are suggested for evaluating the quality level as applied to specific tasks of controlling quality of the electrical equipment used in mining.

  4. Quality control of diagnostic x-ray equipment and film processing

    International Nuclear Information System (INIS)

    1993-01-01

    According to the section 40 of the Radiation Act (592/92), the licensee is required in Finland to make the arrangements to control the function of the radiation equipment and related facilities used for medical procedures. The guide explains how quality control can be organized for diagnostic x-ray equipment. It also gives recommendations for constancy tests for conventional x-ray radiographic and fluoroscopic equipment and for film processing. The recommendations are based on the publications and statements of the International Committee for Radiation Protection (ICRP) and standardization organizations. The intention is that the operators of x-ray equipment or the maintenance personnel are able to perform the quality control tests presented in the guide

  5. Results of pilot project on introducing quality control of mammographic equipment

    International Nuclear Information System (INIS)

    Vasileva, Zh.; Lichev, A.; Dimov, A.; Kostova, E.; Dimov, G.

    2003-01-01

    Objective:The results from a pilot project, realized in the framework of the PHARE Project 'Radiation Protection and Safety in Medical Use of the Ionizing Radiation'. The main goal of the project is the elaboration a quality control program for mammographic equipment and its implementation in 4 radiological units in the country. Another task is to examine the possibility for conducting a mammographic screening using this equipment. Material and methods: The developed quality control program has the following components: test parameters; criteria for intervention; minimal frequency of measurement. Methodologies for measurement of the parameters and assessment of the results in accordance with the European Protocol for physical and technical aspects of the mammographic screening. Standard protocols have been elaborated. Results: The quality program has been tested for three month at different hospitals. Conclusions: Optimization and strict control of the process of film development are needed. The exposure equipment. The quality control program should be implemented on all mammographic equipment in the country. For the performance of mammographic screening a strict selection of the equipment is necessary

  6. Regulation EM-GT-8. Guidance for quality control of mammography equipment

    International Nuclear Information System (INIS)

    2015-01-01

    Objective: To provide practical guidance of technical procedures for carrying out quality control in mammography equipment. Scope: This guide applies to mammography equipment. A number of methods which require the appointed instrumentation described, some of which can be implemented in radiology services own country given the low complexity of themselves and others that require specific equipment and can be performed by specialized groups external to these units. The guide does not constitute a mandatory, however, the parameters evaluated according to the tests described therein and their tolerances form the basis of regulations that establish the CCEEM about these teams. Overview: The success of mammographic studies depends on obtaining high-quality images combined with a low rate of patient dose. To ensure this objective the establishment of quality assurance programs on all aspects involving these services is necessary. This guide provides a number of quality control procedures aimed at x-ray equipment, which must be performed at least on an annual basis or when some maintenance occurs at x-ray equipment.

  7. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for equipment, instruments, and controls? 111.117 Section 111.117 Food and Drugs FOOD AND DRUG ADMINISTRATION... and Process Control System: Requirements for Quality Control § 111.117 What quality control operations...

  8. Regulation EM-GT-7. Quality control of the radiography equipment

    International Nuclear Information System (INIS)

    2015-01-01

    The purpose of this document is to provide practical guidance of technical procedures for carrying out quality control in X-ray equipment. This guide is applicable to general purpose radiography equipment, although some of the procedures may be applied to other types of diagnostic imaging equipment. The tests described require the appointed instrumentation and some of these can be implemented in the radiodiagnostic given the simplicity of them and others require special equipment and can be performed by external specialized groups to these units.

  9. Quality control for dental X-rays equipment and film developers

    International Nuclear Information System (INIS)

    Pomares C, Martin

    1998-01-01

    Quality control in five dental X-ray equipments, film and film developers was done. It was for evaluating the radiologic practices in the odontologic services too. This work was made based on international standards, the results will be used for future works in quality assurance in dental radiology

  10. Guidelines for Quality Control of Equipment Used in Diagnostic Radiology in the Netherlands

    International Nuclear Information System (INIS)

    Berg, L. van den; Aarts, C.N.M.; Beentjes, L.B.; Dalen, A. van; Elsakkers, P.; Julius, H.W.; Kicken, P.J.H.; Meer, F. van der; Teeuwisse, W.; Thijssen, M.A.O.; Zoetelief, J.

    1998-01-01

    The Dutch working group on 'Quality Criteria for Equipment Used in Diagnostic Radiology' has formulated guidelines providing technical criteria for equipment used in conventional diagnostic radiology. These guidelines are applicable to the technical parameters having a major impact on image quality and patient dose and include methods for testing. The following parameters are included: tube voltage, automatic exposure control, film processing, film-screen combination, light tightness and illumination of the dark room, half-value layer and filtration, light field, grid, focal spot size, viewing boxes and geometrical indicators. Each guideline consists of the following chapters: (1) Scope and field of application, (2) Background information, (3) Test procedure, (4) Test frequency, (5) Registration of observations, (6) Evaluation and interpretation, (7) Test report. Chapter 3 includes both the principles of the test method and a step by step description of the procedures. The principles of the test procedure provide a basis for adaptation to local circumstances. The step by step test procedure allows a quality control measurement to be performed with limited physical knowledge of the equipment. Chapter 6 includes limiting values. Draft guidelines were evaluated in practice in 20 hospitals. The final document has been accepted by the professional societies in the Netherlands and the Dutch Minister of Health as a reference set of tools to perform Quality Control of equipment used for conventional diagnostic radiology. (author)

  11. Quality Control Program for radiodiagnostic equipment on the Department of Antioquia, Colombia

    International Nuclear Information System (INIS)

    Beltran, Camilo; Viloria, Carolina; Puerta, Anselmo; Morales, Javier; Martinez, Piedad

    2008-01-01

    The Health Sectional Direction of Antioquia DSSA and the National University of Colombia campus Medellin have been formalizing inter-administrative agreements to realize Quality Control Studies on the institutions of medical radiodiagnostics of the department. In the first phase of the project on 2006, quality control studies were completed on 40 conventional and 31 mammography equipment, in the second phase by the end of 2006, 21 fluoroscopy, interventionism and C arms equipment were also studied; the third phase, finished by the end of 2007, counted with 50 conventional equipment. The tests proposed on the ARCAL XLIX IAEA protocol, tests on the installations, on the generator, on the image systems and the patient dosimetry were performed. From the evaluations on the installations, reports with relevant recommendations to be considerate and implemented to perform a better use of own resources on each institution were elaborated. On this paper, current results, impact on the participating institutions and the benefits from the applications that these kinds of practices bring to the institutions are presented. Finally, the necessity to advance towards clear politics in order to impulse the implementation of quality assurance programs in radiodiagnostic institutions, looking to improve the quality of diagnostic images with patient benefits, higher trust on technical conditions of equipment for a better and adequate diagnose, as well as to advance on processes seeking the optimization of radiological protection on the patient and the personnel occupationally exposed, is presented. (author)

  12. A-Cell equipment removal quality process plan

    International Nuclear Information System (INIS)

    TAKASUMI, D.S.

    1999-01-01

    This document establishes the quality assuring activities used to manage the 324 building A-Cell equipment removal activity. This activity will package, remove, transport and dispose of the equipment in A-Cell. This document is provided to ensure that appropriate and effective quality assuring activities have been incorporated into the work controlling documentation and procedures

  13. Quality control for the equipment of Nuclear medicine: experience of the H.U. de la Princesa

    International Nuclear Information System (INIS)

    Espana, M.L.; Gracia, A.; Prieto, C.; Lopez F, P.

    1998-01-01

    The quality control of the equipment used in a nuclear medicine service is a fundamental aspect in the Quality Assurance Program that in the present time is starting in our hospital. the objective of this work is to present the internal protocol used, its problematic associated with its starting, and the results obtained in the quality control as of the gamma camera as of the activimeter. In addition to the equipment own to the nuclear medicine service it has been used a Cs-137 source and puppets for several purposes. The results obtained demonstrated the stability of the controlled parameters which has led us to a restating of the established periodicities in our internal protocol, over all for some constancy tests. (Author)

  14. Analysis of quality control protocol implementation of equipment in radiotherapy services

    International Nuclear Information System (INIS)

    Calcina, Carmen S. Guzman; Lima, Luciana P. de; Rubo, Rodrigo A.; Ferraz, Eduardo; Almeida, Adelaide de

    2000-01-01

    Considering the importance of the Quality Assurance in the radiotherapy services, there was an interest to make tests' evaluation for a Quality Control for the cobalt equipment, linear accelerator and simulator as a classification and comparison. The work proposed is a suggestion that can serve as tool for medical physicists that are starting to work in the radiotherapy area and for the most experts. The discussions were made by the gathering of local tests and official protocols, resulting in a minimum protocol as a suggestion for a routine work, emphasizing the periodicity and level of tolerance of each one of the tests. (author)

  15. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment

    International Nuclear Information System (INIS)

    Costa, A.M.; Caldas, L.V.E.

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy responses of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities. (author)

  16. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment.

    Science.gov (United States)

    Costa, A M; Caldas, L V E

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy response of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities.

  17. Survey on quality control measurements for nuclear medicine imaging equipment in Finland in 2006

    International Nuclear Information System (INIS)

    Korpela, Helinae; Niemelae, Jarkko

    2008-01-01

    Routine quality control (QC) is an essential requirement in nuclear medicine (NM) in order to ensure optimal functioning of equipment. To harmonise the routine QC of NM imaging equipment in Finnish hospital s (planar gamma cameras, SPECT, coincidence gamma cameras, PET), the Radiation and Nuclear Safety Authority (STUK) will publish guidelines on QC in collaboration with several hospital physicists. Recommendations will be provided on routine QC measurements and on the frequency of testing. It is also planned to provide recommendations for the acceptance criteria when assessing different performance parameters for NM imaging equipment. In order to determine what performance parameters of NM equipment are currently measured in hospitals, how frequently they are measured and what acceptance criteria are used, a survey was carried out on the QC of NM equipment in Finland during 2006. (author)

  18. Evaluation of the Nuclear Medicine facilities in Minas Gerais state: quality control program of equipment

    International Nuclear Information System (INIS)

    Kubo, Tadeu Takao Almodovar; Biancardi, Rodrigo; Rocha, Adriana Marcia Guimaraes; Ferreira, Denia Romao; Silva, Franciele Aquiles Anjos; Assuncao, Jonathan Buenos Aires; Alves, Ederson Henrique; Almeida, Ana Flavia Batista; Alves, Nathalia Fernandes; Xavier, Faber Henrique Zacarias; Gontijo, Rodrigo Modesto Gadelha; Mamede, Marcelo; Universidade Federal de Minas Gerais

    2017-01-01

    With the reformulation of the CNEN-NN-3.05 standard in December 2013, Brazil's Nuclear Medicine (NMS) services have to perform a greater number of quality controls for SPECT and PET equipment. However, little is known about the reality of the quality control programs of these services regarding the application of the new standard. Thus, in this context, the objective of the present study was to evaluate the quality control program of MNSs in the state of Minas Gerais. All NMSs in the state of Minas Gerais were invited to participate in the project. Of these, 34.48% (20 facilities) agreed to participate in the project, 50.00% (29 facilities) did not respond to the invitation and 15.52%(9 facilities) declined their participation. Thus, as of November 2015, 20 SPECT and 2 PET/CT equipment were evaluated for the performance of the quality control tests recommended by the new CNEN standard. The phantoms required for the evaluation came from the Laboratory of Dosimetry and Quality Control of UFMG. Even with the deadlines set by CNEN for the implementation of the quality control program in the NMSs, more than 50% of the evaluated services did not implement the quality controls, and the absence of specific phantoms is the main reason for the failure. Among the problems found in the installations, the most critical were: collimators with no conditions of use in the clinical routine, linearity problems of the evaluated image and values of image uniformity superior to the limits of acceptance. Problems in the uniformity and linearity of the image found directly impacted the performance of other tests, such as spatial resolution, SPECT performance, among others. In a general way, the NMSs in the state of Minas Gerais evaluated with the present study are in clinical feasible conditions. (author)

  19. WP EMPLACEMENT CONTROL AND COMMUNICATION EQUIPMENT DESCRIPTIONS

    International Nuclear Information System (INIS)

    Raczka, N.T.

    1997-01-01

    The objective and scope of this document are to list and briefly describe the major control and communication equipment necessary for waste package emplacement at the proposed nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the required equipment are explained and summarized in the individual subsections of this document. This task was evaluated in accordance with QAP-2-0 and found not to be quality affecting. Therefore, this document was prepared in accordance with NAP-MG-012. The following control and communication equipment are addressed in this document: (1) Programmable Logic Controllers (PLC's); (2) Leaky Feeder Radio Frequency Communication Equipment; (3) Slotted Microwave guide Communication Equipment; (4) Vision Systems; (5) Radio Control Equipment; and (6) Enclosure Cooling Systems

  20. Quality control of repair of equipment for coal preparation plants. Upravlenie kachestvom remonta oborudovaniya ugleobogatitel'nykh fabrik

    Energy Technology Data Exchange (ETDEWEB)

    Okonishnikov, A I; Neskoromnykh, V M; Surzhenko, V S; Sirichenko, R P; Pavlyuchenko, S G; Lesikov, A V

    1984-01-01

    The Ukrniiugleobogashchenie, Kalininsk and Sukhodol'sk coal preparation plants have developed the SUKRO system for control of repair quality of coal preparation equipment in the USSR. The system is based on a system of standards used in coal preparation plants. The following systems of standards used by the SUKRO system are analyzed: organization standards (order of repair in a coal preparation plant, repair planning, spare part systems, methods for determining equipment wear, analysis of equipment failures), standards for maintenance and repair (methods for equipment maintenance, service life of each equipment component or system, structure of preventive repair or repair, organizational models of repair operations, lubrication systems), standards for assessment of labor quality during repair operations. Use of the SUKRO system in the Sukhodol'sk coal preparation plant is evaluated. The SUKRO forms a system of standards for repair and maintenance of equipment considering operation conditions in coal preparation plants, requirements for equipment reliability and service life. (4 refs.)

  1. Advantages of a program of quality control in the nuclear medicine equipment

    International Nuclear Information System (INIS)

    Trujillo Z, F.E.; Argumosa, E.; Herrera R, M.R.

    2007-01-01

    In Nuclear Medicine more 90% of the entirety of the carried out procedures its are with diagnostic ends where it is acquired one or several images. This makes indispensable to have an appropriate operation of the dedicated equipment to produce images and also of those non former images, as the activity caliper, to assure an appropriate quality diagnoses not from the images and the correct dose administration to the patient. In this work the main calibrations that should be carried out and an example of the program of quality control of a gamma camera mark Siemens and model E.CAM are presented. Considerations that should take as for the radiological protection are exposed. Comments on the parameters that correct the required calibrations and the images taken place by an operation or inadequate calibrations are included. In conclusion, the necessity of a program that it contains as minimum the quality control of the gamma cameras and of the activity caliper, having as main advantages a good image quality diagnoses and to minimize the dose imparted the patient are exposed. (Author)

  2. Commercial jet fuel quality control

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, K.H.

    1995-05-01

    The paper discusses the purpose of jet fuel quality control between the refinery and the aircraft. It describes fixed equipment, including various types of filters, and the usefulness and limitations of this equipment. Test equipment is reviewed as are various surveillance procedures. These include the Air Transport Association specification ATA 103, the FAA Advisory Circular 150/5230-4, the International Air Transport Association Guidance Material for Fuel Quality Control and Fuelling Service and the Guidelines for Quality Control at Jointly Operated Fuel Systems. Some past and current quality control problems are briefly mentioned.

  3. Quality control guarantees the safety of radiotherapy

    International Nuclear Information System (INIS)

    Aaltonen, P.

    1994-01-01

    While radiotherapy equipment has seen some decisive improvements in the last few decades, the technology has also become more complicated. The advanced equipment produces increasingly good treatment results, but the condition of the equipment must be controlled efficiently so as to eliminate any defects that might jeopardise patient safety. The quality assurance measures that are taken to show that certain equipment functions as required are known as quality control. The advanced equipment and stricter requirements set for the precision of radiotherapy have meant that more attention must be paid to quality control. The present radiation legislation stipulates that radiotherapy equipment must undergo regular quality control. The implementation of the quality control is supervised by the Finnish Centre for Radiation and Nuclear Safety (STUK). Hospitals carry out quality control in accordance with a programme approved by STUK, and STUK inspectors periodically visit hospitals to check the results of quality control. (orig.)

  4. Controlling the quality of replacement parts in nuclear station, class 1E equipment

    International Nuclear Information System (INIS)

    Pierson, R.K.; Clemons, R.W.

    1984-01-01

    Nuclear station owners have traditionally purchased replacement parts for Class 1E equipment from the original supplier of the equipment. By this method, part and equipment quality could be maintained. In recent years, however, this traditional source of parts has continuously declined as an increasing number of original equipment suppliers stop producing Class 1E equipment or no longer stock parts for older equipment. When replacement parts for Class 1E equipment are not obtainable from the original suppliers, equipment owners have created a variety of methods for assuring the quality of parts obtained from other sources. A standard that provides direction and guidance for maintaining the quality of Class 1E equipment when repaired with parts from alternate sources is, therefore, needed to assure the methods in use are satisfactory and to alert the equipment owners to additional acceptable methods. The standard has now been proposed. IEEE Standard P934 (June, 1983 Draft): ''Requirements for Replacement Parts for Class 1E Equipment in Nuclear Power Generating Stations'' (Ref-3) consist of an introductory section followed by sections on part selection, procurement, replacement (including inspections and tests), non-conforming conditions and records. The proposed standard also includes a non-mandatory appendix on acceptable procurement methods and a summary intended to assist the user in selecting a proper procurement method

  5. Image quality analysis of digital mammographic equipments

    Energy Technology Data Exchange (ETDEWEB)

    Mayo, P.; Pascual, A.; Verdu, G. [Valencia Univ. Politecnica, Chemical and Nuclear Engineering Dept. (Spain); Rodenas, F. [Valencia Univ. Politecnica, Applied Mathematical Dept. (Spain); Campayo, J.M. [Valencia Univ. Hospital Clinico, Servicio de Radiofisica y Proteccion Radiologica (Spain); Villaescusa, J.I. [Hospital Clinico La Fe, Servicio de Proteccion Radiologica, Valencia (Spain)

    2006-07-01

    The image quality assessment of a radiographic phantom image is one of the fundamental points in a complete quality control programme. The good functioning result of all the process must be an image with an appropriate quality to carry out a suitable diagnostic. Nowadays, the digital radiographic equipments are replacing the traditional film-screen equipments and it is necessary to update the parameters to guarantee the quality of the process. Contrast-detail phantoms are applied to digital radiography to study the threshold contrast detail sensitivity at operation conditions of the equipment. The phantom that is studied in this work is C.D.M.A.M. 3.4, which facilitates the evaluation of image contrast and detail resolution. One of the most extended indexes to measure the image quality in an objective way is the Image Quality Figure (I.Q.F.). This parameter is useful to calculate the image quality taking into account the contrast and detail resolution of the image analysed. The contrast-detail curve is useful as a measure of the image quality too, because it is a graphical representation in which the hole thickness and diameter are plotted for each contrast-detail combination detected in the radiographic image of the phantom. It is useful for the comparison of the functioning of different radiographic image systems, for phantom images under the same exposition conditions. The aim of this work is to study the image quality of different images contrast-detail phantom C.D.M.A.M. 3.4, carrying out the automatic detection of the contrast-detail combination and to establish a parameter which characterize in an objective way the mammographic image quality. This is useful to compare images obtained at different digital mammographic equipments to study the functioning of the equipments. (authors)

  6. Image quality analysis of digital mammographic equipments

    International Nuclear Information System (INIS)

    Mayo, P.; Pascual, A.; Verdu, G.; Rodenas, F.; Campayo, J.M.; Villaescusa, J.I.

    2006-01-01

    The image quality assessment of a radiographic phantom image is one of the fundamental points in a complete quality control programme. The good functioning result of all the process must be an image with an appropriate quality to carry out a suitable diagnostic. Nowadays, the digital radiographic equipments are replacing the traditional film-screen equipments and it is necessary to update the parameters to guarantee the quality of the process. Contrast-detail phantoms are applied to digital radiography to study the threshold contrast detail sensitivity at operation conditions of the equipment. The phantom that is studied in this work is C.D.M.A.M. 3.4, which facilitates the evaluation of image contrast and detail resolution. One of the most extended indexes to measure the image quality in an objective way is the Image Quality Figure (I.Q.F.). This parameter is useful to calculate the image quality taking into account the contrast and detail resolution of the image analysed. The contrast-detail curve is useful as a measure of the image quality too, because it is a graphical representation in which the hole thickness and diameter are plotted for each contrast-detail combination detected in the radiographic image of the phantom. It is useful for the comparison of the functioning of different radiographic image systems, for phantom images under the same exposition conditions. The aim of this work is to study the image quality of different images contrast-detail phantom C.D.M.A.M. 3.4, carrying out the automatic detection of the contrast-detail combination and to establish a parameter which characterize in an objective way the mammographic image quality. This is useful to compare images obtained at different digital mammographic equipments to study the functioning of the equipments. (authors)

  7. The method innovation in nuclear equipment quality witness tracing and management

    International Nuclear Information System (INIS)

    Hao Guang

    2012-01-01

    The total construction cost of a nuclear power plant, equipment procurement cost accounts for about 47%-53%. Whether the quality of equipment can meet the technical requirements plays a significant role in the operation and maintenance of a nuclear power plant. Only if we adopt effective management can the equipment quality be ensured. As the most important method of quality control, the effective attendance and track of quality witness points has a crucial effect on contract smooth implementation as well. The essay mainly illustrates the method of quality witness point tracing and management and how to incorporate serious minded ideas and all take part in ways into quality management, hoping to offer some enlightenment on the innovation of nuclear power equipment quality management. (author)

  8. Quality control in dental diagnostic radiology : anomalous in the use of radiological equipment

    International Nuclear Information System (INIS)

    Alcaraz, M.; Martinez-Beneyto, Y.; Jodar, S.; Velasco, E.; Garcia-Vera, M. C.

    2004-01-01

    7,176 official quality control reports on dental diagnostic radiology were studied, relating to dental clinics located in 37 Spanish provinces covering 16 different autonomous Regions. The reports were issued as a result of the entry into force of Royal Decree 2071/1995 on quality control in General Diagnostic Radiology facilities, this Royal Decree was replaced by R. D. 1976/1999. The reports were writen by the UTPR (Technical Unit of Radiological Protection) Agsigma S. A. L., a company approved by the Nuclear Safety Council, and they correspond with the official reports issued during 1996-2001. This meants that a 5-year period has been monitored in order to observe the impacts of the establlishment of this legislation on quality control in intraoral dental diagnostic radiology facilities. The results show that 72.79% of the reports checked in 2001 would comply with the European Union's official recommendation (70 kVp, 8 mA> 1.5 mm of Al and 20 cm collimator length). Significant alterations have detected in a third (30.59%) of the radiological equipment. (Author) 36 refs

  9. Manual on quality assurance for installation and commissioning of instrumentation, control and electrical equipment in nuclear power plants

    International Nuclear Information System (INIS)

    1989-01-01

    The present Manual on Quality Assurance (QA) for Installation and Commissioning of Instrumentation, Control and Electrical (ICE) Equipment of Nuclear Power Plants contains supporting material and illustrative examples for implementing basic requirements of the quality assurance programme in procurement, receiving, installation and commissioning of this equipment. The Manual on Quality Assurance for Installation and Commissioning of ICE Equipment is designed to supplement and be consistent with the Guidebook as well as with the IAEA Code and Safety Guides on Quality Assurance. It is intended for the use of managerial staff and QA personnel of nuclear power plant owners or the organizations respectively responsible for the legal, technical, administrative and financial aspects of a nuclear power plant. The information provided in the Manual will also be useful to the inspection staff of the regulatory organization in the planning and performance of regulatory inspections at nuclear power plants

  10. Constancy check of beam quality in conventional diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Costa, Alessandro M.; Badin, Romulo S.; Leite, Marina S.; Caldas, Linda V.E.

    2008-01-01

    A tandem ionization chamber was developed for quality control programs of X-ray equipment used in conventional radiography and mammography. A methodology for the use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities was established. The application at a medical X-ray imaging facility of this established methodology is presented. The use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities is a useful method to control the performance of the X-ray equipment

  11. First steps in quality control equipment MRI; Primeros pasos en el control de calidad de equipos de imagen por resonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Alonso Diaz, M.; Castaneda Arronte, M. J.; Ferreiros Vazquez, N.; Sanchez Merino, G.

    2011-07-01

    The present work aims to develop the initial stages of a program of quality control of nuclear magnetic resonance equipment. Not intended to conduct a comprehensive study covering all aspects of quality control, but gather the steps are followed and the most common problems they are encountering during the development of this program. It has been claimed that the work will be helpful to others facing the same task. Have been studied the compatibility of mannequins and procedures for the various teams. Ideally, such controls should be independent of the procedures and mannequins own commercial houses.

  12. Survey of Equipment Quality Control in Radiotherapy Centers in Croatia: First Results

    International Nuclear Information System (INIS)

    Jurkovic, S.; Diklic, A.; Smilovic Radojcic, Dj.; Svabic, M.; Kasabasic, M.; Ivkovic, A.; Faj, D.

    2011-01-01

    Implementation of advanced radiation therapy techniques into clinical practice has a huge influence on tumour control as well as normal tissue sparing. Introduction of Conformal Radiation Therapy (CRT) and Intensity Modulated Radiation Therapy (IMRT) into clinical practice results in precise 'tailoring' of dose distributions and according to that in reduction of irradiated volumes. This is not possible without, for the application of advanced radiation therapy techniques constructed, linear accelerators. They must be very precise, well tuned and maintained. In this way the milestone of radiation therapy quality assurance programme is machine quality control (QC). First step in development of quality control programme is existence of written QC protocols. The survey of existence of written QC protocols showed the lack of written protocols for QC procedures in Croatian radiotherapy departments. In this way regular implementation of the procedures are usually left to the conscience of the medical physicists. In the IAEA granted projects CRO6008 and RER9093, we harmonized existing QC protocols between radiation therapy departments at University hospitals Rijeka and Osijek and developed the new ones. The protocols made according to international guidelines are publicly available at websites of the State Office for Radiological and Nuclear Safety and Croatian medical physics society in order to help other radiotherapy departments in Croatia to develop their own ones. Next step was reviewing of QC practices in different centres and exchanging experiences. For that purpose we defined a set of tests, according to the existing QC protocols. Then, on-site measurements were done to check QC parameters of linear accelerators and simulators in six radiation therapy centres in Croatia. In this paper we present the tests preformed, devices and analysing tools used, along with the overall results. Tests were preformed in six radiotherapy centres in Croatia on nine linear

  13. Quality control test solutions for diagnostic radiology, nuclear medicine and health physics with PTW equipment

    International Nuclear Information System (INIS)

    Froescher, Olga

    2007-01-01

    Complete test of publication follows. In 1922 PTW-Freiburg was founded to produce and market a revolutionary new electromechanical component for measuring very small electrical charges. Today PTW is the specialist and one of the global market leaders for manufacturing and supplying high-quality products in diagnostic radiology, nuclear medicine, radiation therapy and health physics. The quality control of X-ray images is influenced by a number of parameters. To maintain a consistent performance of X-ray installations, quality checks have to be conducted regularly. PTW offers a variety of diagnostic test tools for different X-ray devices, and therefore to reduce patient exposure and costs for X-ray departments. PTW's 'Code of Practice' defines in an easy and compact way how to perform quality control measurements on different diagnostic X-ray installations. The necessary equipment for measuring main parameters as well as acceptable limits are mentioned accordingly. The 'Code of Practice' bases on actual standards.

  14. Establishment of an X radiation equipment quality control programme using non invasive meters

    International Nuclear Information System (INIS)

    Lucena, Rodrigo Ferreira de

    2010-01-01

    The objective of this work was to study the behavior of the mainly X ray equipment calibration laboratory of IPEN, operated in the range from 25 kV to 150 kV using a PTW non invasive meter, model Diavolt TM , and an ORTEC spectrometry system, model NOMAD-PLUS 92X, for the establishment of a quality control programme. The Diavolt meter was used for measurements of air kerma, peak voltage and practical peak voltage. The measurements were made varying parameters such as electrical current, X radiation quality for radiation diagnostic, angulations of the meter and its distance in relation to the focal spot of the X ray tube. The results were compared with data found in the literature. Several spectra were generated with the spectrometer system with the purpose of determine the peak voltage in function of the nominal voltage and to characterize the radiation qualities for radiation diagnostic previously determined. The established quality control programme enables the management of the appropriate functioning of the measurement instruments (ionization chambers, voltage and current meter and spectrometer) as well as of the X radiation system. This work also has proposed a time interval to run each one of the tests. (author)

  15. Quality control of conventional diagnostic radiology equipment in Serbia and Montenegro

    International Nuclear Information System (INIS)

    Ciraj, O.; Kosutic, D.; Markovic, S.

    2003-01-01

    There are more than 1500 diagnostic X-ray tubes in service in Serbia and Montenegro. Diagnostic X-ray equipment is checked on annual basis. X-ray equipment Qc protocols have been adopted from several international standards and guidelines [1,2], which have been modified according our practice and measuring equipment. According our inventory, about one half of all installed units is used for conventional X-ray diagnostics, 10% are mobile units, 2% of all in units in operation are mammographic devices an another 2% are computed tomography units. In addition there are about 600 dental X-ray units, which is 36% of all units. It is worth mentioning that almost 30 % of all installed units have single-phase generators, another 25% are tree phase (six and twelve pulse) generators and nearly 9% are high frequency units. Majority of units was installed more than 25 years ago. The Quality Control (QC) in radiography is a central part of QA programme, which deals with equipment maintenance and monitoring. QA in diagnostic radiology is a mean of maintaining standards in imaging and working towards minimizing patient and staff doses. As a part of QA programme in diagnostic radiology, the performance characteristics of 96 conventional X-ray units were measured in six months period during 2003. The diagnostic units were located in hospitals all over the country. They represent 25% of the total conventional diagnostic units of the country. About one half of measured X-ray units were new-installed. QC program has positive effect on X-ray equipment performance in a period of a few years. It is essential to perform QC tests for all installed X-ray units at least on annual basis. This would lead to production of consistent X-ray images, with minimal retake rate and hence, will contribute to decreasing of the patient dose. Patient doses are determined by multitude factors which interact in very complicated manner. It is very important to perform real patient dose measurements in

  16. Objective masurement of image quality in fluoroscopic x-ray equipment FluoroQuality

    CERN Document Server

    Tapiovaara, M

    2003-01-01

    The report describes FluoroQuality, a computer program that is developed in STUK and used for measuring the image quality in medical fluoroscopic equipment. The method is based on the statistical decision theory (SDT) and the main measurement result is given in terms of the accumulation rate of the signal-to-noise ratio squared (SNR sup 2 sub r sub a sub t sub e). In addition to this quantity several other quantities are measured. These quantities include the SNR of single image frames, the spatio-temporal noise power spectrum and the temporal lag. The measurement method can be used, for example, for specifying the image quality in fluoroscopic images, for optimising the image quality and dose rate in fluoroscopy and for quality control of fluoroscopic equipment. The theory behind the measurement method is reviewed and the measurement of the various quantities is explained. An example of using the method for optimising a specified fluoroscopic procedure is given. The User's Manual of the program is included a...

  17. Results of evaluation of quality control measurement instrument of x-ray diagnostic equipment by non-invasive method

    International Nuclear Information System (INIS)

    Laan, Flavio T. van der; Elbern, Alvin W.

    1996-01-01

    This work shows the results of the tests realized on Santa Rita Hospital (Porto Alegre), using a non invasive quality control measurement instrument, developed in this University for fast measurement of essential parameters of X-rays diagnostic equipment. In the tests we used a diagnostics Siemens X ray, model Heliofos 4E as our standard equipment. The linearity test of sensor probe and the exposure rate calibration was performed, with a Palmer Dosimeter. For the kVp and exposure time we used a RTI commercial instrument. (author)

  18. 2. Product quality control and assurance system

    International Nuclear Information System (INIS)

    1990-01-01

    Product quality control and assurance are dealt with in relation to reliability in nuclear power engineering. The topics treated include product quality control in nuclear power engineering, product quality assurance of nuclear power plant equipment, quality assurance programs, classification of selected nuclear power equipment, and standards relating to quality control and assurance and to nuclear power engineering. Particular attention is paid to Czechoslovak and CMEA standards. (P.A.). 2 figs., 1 tab., 12 refs

  19. Preventive maintenance prioritization index of medical equipment using quality function deployment.

    Science.gov (United States)

    Saleh, Neven; Sharawi, Amr A; Elwahed, Manal Abd; Petti, Alberto; Puppato, Daniele; Balestra, Gabriella

    2015-05-01

    Preventive maintenance is a core function of clinical engineering, and it is essential to guarantee the correct functioning of the equipment. The management and control of maintenance activities are equally important to perform maintenance. As the variety of medical equipment increases, accordingly the size of maintenance activities increases, the need for better management and control become essential. This paper aims to develop a new model for preventive maintenance priority of medical equipment using quality function deployment as a new concept in maintenance of medical equipment. We developed a three-domain framework model consisting of requirement, function, and concept. The requirement domain is the house of quality matrix. The second domain is the design matrix. Finally, the concept domain generates a prioritization index for preventive maintenance considering the weights of critical criteria. According to the final scores of those criteria, the prioritization action of medical equipment is carried out. Our model proposes five levels of priority for preventive maintenance. The model was tested on 200 pieces of medical equipment belonging to 17 different departments of two hospitals in Piedmont province, Italy. The dataset includes 70 different types of equipment. The results show a high correlation between risk-based criteria and the prioritization list.

  20. Quality assurance applied to mammographic equipments using phantoms and software for its evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Mayo, Patricia, E-mail: p.mayo@titaniast.co [Titania Servicios Tecnologicos S.L., Grupo Dominguis, Apartado 46015, Valencia (Spain); Rodenas, Francisco [Departamento de Matematica Aplicada, Universidad Politecnica de Valencia, Apartado 46022, Valencia (Spain); Manuel Campayo, Juan [Hospital Clinico Universitario de Valencia, Avda. Blasco Ibanez, Apartado 46017, Valencia (Spain); Verdu, Gumersido [Departamento de Ingenieria Quimica y Nuclear, Universidad Politecnica de Valencia, Apartado 46022, Valencia (Spain)

    2010-07-21

    The image quality assessment in radiographic equipments is a very important item for a complete quality control of the radiographic image chain. The periodic evaluation of the radiographic image quality must guarantee the constancy of this quality to carry out a suitable diagnosis. Mammographic phantom images are usually used to study the quality of images obtained by determined mammographic equipment. The digital image treatment techniques allow to carry out an automatic analysis of the phantom image. In this work we apply some techniques of digital image processing to analyze in an automatic way the image quality of mammographic phantoms, namely CIRS SP01 and RACON for different varying conditions of the mammographic equipment. The CIRS SP01 phantom is usually used in analogic mammographic equipments and the RACON phantom has been specifically developed by authors to be applied to acceptance and constancy tests of the image quality in digital radiographic equipments following recommendations of international associations. The purpose of this work consists in analyzing the image quality for both phantoms by means of an automatic software utility. This analysis allows us to study the functioning of the image chain of the mammographic system in an objective way, so an abnormal functioning of the radiographic equipment might be detected.

  1. Quality assurance applied to mammographic equipments using phantoms and software for its evaluation

    International Nuclear Information System (INIS)

    Mayo, Patricia; Rodenas, Francisco; Manuel Campayo, Juan; Verdu, Gumersido

    2010-01-01

    The image quality assessment in radiographic equipments is a very important item for a complete quality control of the radiographic image chain. The periodic evaluation of the radiographic image quality must guarantee the constancy of this quality to carry out a suitable diagnosis. Mammographic phantom images are usually used to study the quality of images obtained by determined mammographic equipment. The digital image treatment techniques allow to carry out an automatic analysis of the phantom image. In this work we apply some techniques of digital image processing to analyze in an automatic way the image quality of mammographic phantoms, namely CIRS SP01 and RACON for different varying conditions of the mammographic equipment. The CIRS SP01 phantom is usually used in analogic mammographic equipments and the RACON phantom has been specifically developed by authors to be applied to acceptance and constancy tests of the image quality in digital radiographic equipments following recommendations of international associations. The purpose of this work consists in analyzing the image quality for both phantoms by means of an automatic software utility. This analysis allows us to study the functioning of the image chain of the mammographic system in an objective way, so an abnormal functioning of the radiographic equipment might be detected.

  2. 40 CFR 51.359 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts are...

  3. Photoelectric detectors used in laser based control and alignment equipment

    International Nuclear Information System (INIS)

    Chis, I.; Ciura, A.I.; Udrea, M.V.

    1988-03-01

    Some theoretical considerations and practical results regarding the utilization of the ROL 50 photovoltaic cell in a leveling control system and glass quality control equipment are presented. (authors)

  4. Pilot program of quality control in mammography and conventional equipment in the Antioquia Department

    International Nuclear Information System (INIS)

    Martinez, P.; Puerta, J.A.; Morales, J.; Beltran, C.C.

    2006-01-01

    The Sectional Health Division of Antioquia and the National University of Colombia- Medellin Headquarters formalized an agreement for the realization of the quality control of thirty mammographs and twenty-five conventional X-ray equipment located in the one metropolitan area of Medellin, and ten municipalities of the nine regions in that the antioquen county is divided. The National University of Colombia- Headquarters Medellin possesses a program for the formation in quality control and radiological protection at master level in physics for that which endowed a radiodiagnostic laboratory for these purposes. In the Antioquia department only exists an institution, the San Vicente of Paul University Hospital that possesses a quality control program in radiodiagnostic; this hospital given its great volume of studies in radiodiagnostic has a medical physicist and of that instrumental necessary to maintain the program. The quality control programs have not been implemented in the rest of health institutions, public or private, big or small, until the moment. The project then allowed to carry out an initial evaluation of the pertinent parameters of the quality control of the facilities like its are those that refer to the state of the x-ray generator, the disposition of the installation, the dark room, the film processor and negatoscopies room; these its were carried out with base in the protocol produced in the ARCAL XLIX project in which participated six Latin American countries. The dose average in mammography, following the proposed course in the ARCAL LXXV, where its participate eleven Latin American countries was also evaluated. This study pilot serves like reference of the current state of the regional radiodiagnostic services, with base in this sampling that is representative. The obtained data gave the necessary information so that the Sectional Division of Health of Antioquia can generate tending actions to the implementation of quality guarantee programs and

  5. Quality control for the equipment of Nuclear medicine: experience of the H.U. de la Princesa; Control de calidad del equipamiento en Medicina Nuclear. Experiencia enel H.U. de la Princesa

    Energy Technology Data Exchange (ETDEWEB)

    Espana, M.L.; Gracia, A.; Prieto, C.; Lopez F, P. [Servicio de ProteccionRadiologica. Hospital Universitario de la Princesa C/ Diego de Leon 62, 28006Madrid (Spain)

    1998-12-31

    The quality control of the equipment used in a nuclear medicine service is a fundamental aspect in the Quality Assurance Program that in the present time is starting in our hospital. the objective of this work is to present the internal protocol used, its problematic associated with its starting, and the results obtained in the quality control as of the gamma camera as of the activimeter. In addition to the equipment own to the nuclear medicine service it has been used a Cs-137 source and puppets for several purposes. The results obtained demonstrated the stability of the controlled parameters which has led us to a restating of the established periodicities in our internal protocol, over all for some constancy tests. (Author)

  6. Control system of digital x-ray systems by quality parameters

    International Nuclear Information System (INIS)

    Balashov, S.V.; Kovalenko, Yu.N.

    2013-01-01

    The paper proposed a control system of X-ray digital equipment on quality indicators. Two basic parameters were determined: image quality and patients' radiation load. A method for monitoring these indicators is proposed. The criterion of equipment suitability is to obtain control digital X-ray images of diagnostically acceptable quality at a fixed low entrance dose in the plane of the digital detector. It is shown that the control system of X-ray digital equipment based on indicators of quality is the most appropriate in situations of deficit of financial resources, since minimizing the costs for the purchase and running of control systems, does not require highly skilled technical personnel, and reduces the duration of the equipment inspection. (authors)

  7. Network-based production quality control

    Science.gov (United States)

    Kwon, Yongjin; Tseng, Bill; Chiou, Richard

    2007-09-01

    This study investigates the feasibility of remote quality control using a host of advanced automation equipment with Internet accessibility. Recent emphasis on product quality and reduction of waste stems from the dynamic, globalized and customer-driven market, which brings opportunities and threats to companies, depending on the response speed and production strategies. The current trends in industry also include a wide spread of distributed manufacturing systems, where design, production, and management facilities are geographically dispersed. This situation mandates not only the accessibility to remotely located production equipment for monitoring and control, but efficient means of responding to changing environment to counter process variations and diverse customer demands. To compete under such an environment, companies are striving to achieve 100%, sensor-based, automated inspection for zero-defect manufacturing. In this study, the Internet-based quality control scheme is referred to as "E-Quality for Manufacturing" or "EQM" for short. By its definition, EQM refers to a holistic approach to design and to embed efficient quality control functions in the context of network integrated manufacturing systems. Such system let designers located far away from the production facility to monitor, control and adjust the quality inspection processes as production design evolves.

  8. Quality control of radiodiagnostics

    International Nuclear Information System (INIS)

    Alonso Diaz, M.; Castaneda Arronte, M.J.; Matorras Galan, P.; Diaz-Caneja Rodriguez, N.; Gutierrez Diaz Velarde, I.

    1993-01-01

    Since May 1990, a program of quality control of diagnostic X-ray equipment is underway in the University Hospital Marques de Valdecilla. This includes the design and application of measuring specifications and procedures corresponding to the different parameters of the equipment. The specified values are presented, as are those obtained for geometric and exposition parameters using the equipment. The specifications for the geometric parameters are fulfilled in an large proportion (between 52 and 86%) of the units, and the rest can easily be adjusted. However, 85% of the units can be made to operate with a field larger than that of the screen of the image monitor and approximately half of them can operate at a shorter focus-to-patient distance than that specified. With respect to the exposition parameters, in general, these units do not fulfill the specifications and their behavior is not uniform. The results obtained indicate that the equipment studied could be made to comply with the proposed specifications if a Maintenance Program were initiated in coordination with that of Quality Control. (Author)

  9. Quality control procedures for equipment: The EORTC radiotherapy group experience

    International Nuclear Information System (INIS)

    Garavaglia, G.; Mijnheer, B.

    1997-01-01

    The QA program of the Radiotherapy Co-operative Group of the EORTC (European Organisation for Research and Treatment of Cancer) has included quality control procedures for equipment from its starting date in 1982. During on-site visits carded out by a team of radiotherapists and physicists the following equipment checks and measurements were performed: mechanical and beam alignment checks of simulator and therapy units; measurements of the dose homogeneity for X-ray and electron beams; intercomparison of ionization chambers; measurements of the depth dose distribution at several depths; absorbed dose determination in specific points in water for several combinations of field sizes and accessories, for photon and electron beams. In addition calculations of treatment time and monitor units were carried out for reference cases and the relevant beam data from all machines in use were collected. In order to provide a follow-up of the on-site visits, a mailed TLD program was then established in 1986. The program has been very successful, the centers are eager to participate since it constitutes an independent check of the measurements performed by the local physicists. It also allows to detect dosimetric problems in centers not yet included in the site visit program. To date, all participating centers have been monitored by mailed TLD, several more than once. This has led to the decision of stopping the site visits unless large deviations cannot be resolved by a second TLD mailing. The Radiation Physics Department of the Goeteborg, University Hospital has been the main partner in this QA effort. Since 1993 the mailed TLD program continues in co-operation with the Institut Gustave Roussy in Villejuif. Besides water phantom measurements on the beam axis, the IGR, in collaboration with the Radiation Physics Center in Houston, is planning a procedure to check off-axis doses by means of a TLD-loaded multi-purpose phantom. (author)

  10. Comparison between the implementation of quality criteria of radiographic image in conventional and digital mammography equipments

    International Nuclear Information System (INIS)

    Alcantara, M.C.; Sordi, G.M.A.A.; Caldas, L.V.E.; Furquim, T.A.C.

    2008-01-01

    The mammographic examination needs a strict quality control. A publication of the European Commission provides guidelines on quality criteria for the images of the breast, quantifying the quality obtained in the image. Following the recommendations of the European Commission, two kinds of mammographic equipments, at a same institution, were evaluated to compare the quality of the conventional and digital images. Besides of that, the Average Glandular Dose (AGD) and the Entrance Surface Dose (ESD) were measured by using an ionization chamber (Radcal, 6M) in the radiation beams of each equipment. The digital equipment fulfills more quality criteria than the conventional equipment, provided ESD values, AGD values and a rejection index lower than the conventional equipment. Therefore, the digital mammography can be considered more adequate than the conventional one, both for criteria analyses and for dose optimization. (author)

  11. Tool for the verification of geometrical parameters and constancy of image quality in radiology equipment

    International Nuclear Information System (INIS)

    Mayo, P.; Verdu Martin, G.; Rodenas Escriba, F.; Marin Peinado, B.; Camapyo Esteban Nogueira, J. M.; Diez Domingo, S.; Villaescusa Blanca, J. I.; Hernando Gonzalez, I.; Ruiz Manzano, P.; Rivas Ballarin, M. A.; Melcho Iniguez, M.; Asensio Martinez, M. I.

    2013-01-01

    This paper presents the application of an innovative tool developed for the detailed quality control of diagnostic equipment. We have tried to validate such a tool for verification of geometrical parameters and the evaluation of the constancy of the image quality in radiology equipment, evaluating their usefulness by various services of Radio physics and radiation protection of different hospitals. (Author)

  12. A survey in Portuguese X-ray fluoroscopy equipment: dose rates and image quality

    International Nuclear Information System (INIS)

    Teixeira, Nuno G.; Cunha, Gilda R.; Coutinho, Guilherme M.; Trindade, Hugo R.; Carvoeiras, Pedro P.

    2015-01-01

    X-ray fluoroscopy is essential in both diagnosis and medical intervention, although it may contribute to significant radiation doses to patients that have to be optimised and justified. Therefore, it is crucial to the patient to be exposed to the lowest achievable dose without compromising the image quality. The purpose of this study was to perform an analysis of the quality control measurements, particularly dose rates, contrast and spatial resolution of Portuguese fluoroscopy equipment and also to provide a contribution to the establishment of reference levels for the equipment performance parameters. Measurements carried out between 2007 and 2013 on 143 fluoroscopy equipment distributed by 34 nationwide health units were analysed. The measurements suggest that image quality and dose rates of Portuguese equipment are congruent with other studies, and in general, they are as per the Portuguese law. However, there is still a possibility of improvements intending optimisation at a national level. (authors)

  13. Country-wide quality control of equipment in Norwegian laboratories performing in vivo nuclear medicine examinations

    International Nuclear Information System (INIS)

    Skretting, A.; Rootwelt, K.; Berthelsen, T.

    1984-01-01

    The report presents the methods used and the results obtained in quality control tests performd in all Norwegian hospital laboratories performing in vivo nuclear medicine examinations. The tests included activity meters and scintillation cameras. The activity meters were tested by means of calibrated, long-lived radioactive sources. The quality of these instruments were judged to be satisfactory for moderate and high activities, non of them showing a deviation of more than 10% from the calibration value. Deviations were larger at low activities and were for some laboratories unacceptable. The scintillation cameras test included studies of flood field (homogeneity), geometrical resolution and energy resolution, as well as measurements of count rate characteristics and sensitivity. 40% of the cameras were judged to have flood field responses with satisfactory homogeneity, whereas 32% of the cameras had a satisfactory resolution ability. A liver/abdomen phantom test was carried out by the staff of the actual laboratory. This test proved that only 20% of the laboratories had a satisfactory total performance, managing to detect and describe satisfactorily 4 out of 5 simulated defects in the liver phantom. Lack of information density and insufficient number of projections was the main reason for unsatisfactory results with good cameras. It is recommended that quality control equipment as used in the described tests should be made available to Norwegian hospitals for self assessment. Regular quality assurance tests as recommended by the Norwegian Association for Radiation Physics and Norwegian Society of Nuclear Medicine should be implemented in all hospitals. Moreover, a practical training course in quality assurance should be arranged. (RF)

  14. Characterization of a PET-NEMA/IEC body phantom for quality control tests of PET/CT equipment

    International Nuclear Information System (INIS)

    Oliveira, Cassio M.; Vieira, Igor F.; Lima, Fernando R.A.; Sa, Lidia V. de

    2011-01-01

    The Brazilian Sanitary Agency from Ministry of Health requires that all PET/CT equipment must undergo minimal quality control tests using manufacturer simulators. The PET-NEMA/IEC body phantom is recommended by the IEC and NEMA to perform acceptance testing and quality control in PET/CT equipment according to specific protocols. It is essential that all simulator components (spheres and body) are properly characterized in relation to their size and internal structure volumes, since they are used to calculate the overall activity concentration and the total weight. The objective of this work was characterize a PET-NEMA/IEC body phantom for the true reconstruction in computational modeling and correct analysis of experimental results. The simulator is basically composed of three structures: the body (simulating a portion of the chest), an inner cylinder (simulating the lung tissue) and a top cover in which are coupled spheres of different sizes simulating 'hot' (tumors) and cold lesions. The spheres were evaluated in terms of volume. The same evaluations were performed with the body of the simulator and the inner cylinder, beyond of analysis of their weights (filled with water) and wall thickness. The data showed that the total weight of the simulator with all its internal structures is 12.5 kg and the volume of the 'hot' and 'cold' spheres are approximately equal to those presented by the manufacturer. The inner cylinder volume showed a significant difference between the measured and the presented in the manual. The results were used for reconstruction of the simulator in computational modeling using the code GATE. (author)

  15. Implementation of a quality control program of the equipment of the nuclear medicine services in Chile

    International Nuclear Information System (INIS)

    Astudillo, R.; Diaz, G.; Ferreira, A.; Garcia, M.; Hermosilla, A.; Pacheco, F.; Vasquez, M.; Coca, M.

    2014-08-01

    Now days in Chile there are more of 43 Nuclear Medicine centers; most of them have gamma cameras in order to study physiological process in diagnostic and treatment of patients pathologies. This requires having the equipment in optimal operating condition and it is ensured with quality control programs that are based on a series of tests relating to protocols, such as TECDOC-602 y AAPM No.6. Planar test often applied in gamma cameras including: spatial resolution, spatial linearity, sensitivity and uniformity. SPECT tests consider: tomography uniformity, rotation center tomography resolution and total performance. The tests in dose calibrator are: background measurement, accuracy, precision, linearity and reproducibility. The tests above require the use of radioactive sources and specific simulators patterns or phantom based on international standards such as The National Electrical Manufacturers Association (Nema), International Atomic Energy Agency (IAEA) and The American Association of Medical Physics (AAPM). In this work we carried out several tests of quality control in a Nuclear Medicine Center of Temuco and we propose to implement the applied methodology in others similar Chilean centers. (author)

  16. Traps in quality assurance of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Meier, N.; Lenzen, H.; Fiebich, M.

    1992-01-01

    With the introduction of the German industrial protocol for quality assurance of X-ray equipment, everybody using X-ray machines fell into sort of trap or found some of the procedures misleading. Vigorous discussions were held on every conceivable aspect of this and other protocols, and are still in progress. This paper points out some of the common traps and considers a new type dosimeter, which allows a definite separation of quality assurance of X-ray equipment and of processing and which can also be used in future for quality assurance of digital radiography equipment. (orig.) [de

  17. Routine quality control of high dose rate brachytherapy equipment

    International Nuclear Information System (INIS)

    Guzman Calcina, Carmen S.; Almeida, Adelaide de; Rocha, Jose R. Oliveira

    2001-01-01

    A Quality Assurance program should be installed also for High Dose Rate brachytherapy, in the order to achieve a correct dose administration to the patient and for the safety to those involved directly with the treatment. The work presented here has the following purposes: Analyze the types of equipment tests presented by the official protocols (TG40, TG56 e ARCAL XXX), evaluate the brachytherapy routine tests of protocols from various national and international radiotherapy services and compare the latter with those presented in the official protocols. As a result, we conclude the following: TG56 presents a higher number of tests when compared to the other official protocols and most of the tests presented by the analyzed services are present in TG56. A suggestion for a basic protocol is presented, emphasizing the periodicity and tolerance level of each of the tests. (author)

  18. Water quality control system and water quality control method

    International Nuclear Information System (INIS)

    Itsumi, Sachio; Ichikawa, Nagayoshi; Uruma, Hiroshi; Yamada, Kazuya; Seki, Shuji

    1998-01-01

    In the water quality control system of the present invention, portions in contact with water comprise a metal material having a controlled content of iron or chromium, and the chromium content on the surface is increased than that of mother material in a state where compression stresses remain on the surface by mechanical polishing to form an uniform corrosion resistant coating film. In addition, equipments and/or pipelines to which a material controlling corrosion potential stably is applied on the surface are used. There are disposed a cleaning device made of a material less forming impurities, and detecting intrusion of impurities and removing them selectively depending on chemical species and/or a cleaning device for recovering drain from various kinds of equipment to feedwater, connecting a feedwater pipeline and a condensate pipeline and removing impurities and corrosion products. Then, water can be kept to neutral purified water, and the concentrations of oxygen and hydrogen in water are controlled within an optimum range to suppress occurrence of corrosion products. (N.H.)

  19. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    The practice of nuclear diagnostic imaging requires an appropriate quality assurance program to attain high standards of efficiency and reliability. The International Atomic Energy Agency defines the term quality assurance as ''the closeness with which the outcome of a given procedure approaches some ideal, free from all errors and artifacts.'' The term quality control is used in reference to the specific measures taken to ensure that one particular aspect of the procedure is satisfactory. Therefore, quality assurance is a hospital-wide concept that should involve all aspects of clinical practice. Quality control is concerned with the submission of requests for procedures; the scheduling of patients; the preparation and dispensing of radiopharmaceuticals; the protection of patients, staff, and the general public against radiation hazards and accidents caused by radioactive materials or by faulty equipment; the setting up, use, and maintenance of electronic instruments; the methodology of the actual procedures; the analysis and interpretation of data; the reporting of results; and, finally, the keeping of records. The chapter discusses each of these areas

  20. Control cards as a statistical quality control resource

    Directory of Open Access Journals (Sweden)

    Aleksandar Živan Drenovac

    2013-02-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 This paper proves that applying of statistical methods can significantly contribute increasing of products and services quality, as well as increasing of institutions rating. Determining of optimal, apropos anticipatory and limitary values, is based on sample`s statistical analyze. Control cards represent very confident instrument, which is simple for use and efficient for control of process, by which process is maintained in set borders. Thus, control cards can be applied in quality control of procesess of weapons and military equipment production, maintenance of technical systems, as well as for seting of standards and increasing of quality level for many other activities.

  1. Automatic dose-rate controlling equipment

    International Nuclear Information System (INIS)

    Szasz, T.; Nagy Czirok, Cs.; Batki, L.; Antal, S.

    1977-01-01

    The patent of a dose-rate controlling equipment that can be attached to X-ray image-amplifiers is presented. In the new equipment the current of the photocatode of the image-amplifier is led into the regulating unit, which controls the X-ray generator automatically. The advantages of the equipment are the following: it can be simply attached to any type of X-ray image-amplifier, it accomplishes fast and sensitive regulation, it makes possible the control of both the mA and the kV values, it is attached to the most reliable point of the image-transmission chain. (L.E.)

  2. Maintenance of electromechanical equipment in quality organization under operating conditions

    International Nuclear Information System (INIS)

    Mercier, J.P.

    1984-01-01

    The paper outlines the principles adopted by the Thermal Production Service of Electricite de France on the basis of the experience of the first years of operation of its 900 MW(e)PWR units for the purpose of improving quality organization in operating conditions in respect of the maintenance of electromechanical safety equipment. This organization is based on application of the usual principles for quality assurance, adapted in accordance with current French regulations. The paper first recalls the now traditional methods of applying the principles of quality organization in the area of equipment maintenance. It then defines particular so-called ''delicate'' activities which, in accordance with the above regulations, are subjected to additional quality organizational procedures; this applies in particular to the area of pre-maintenance preparation and studies and to the control exercised by the French safety authorities over the execution of those activities. The paper explains how the application of the regulations improves maintenance practices compared with standard quality organization. It describes how the attempt to establish a frontier between these two types of activity (current and ''delicate'') has led to the definition of a classification criterion which is technically correct and simple to use and is based on the professional skills of those performing each activity. The paper then describes in greater detail the principal rules for the performance of those tasks which come under the standard organization and those to which more stringent criteria apply. Lastly, it explains the thinking behind equipment surveillance programmes and the analysis of anomalies discovered through surveillance measures or brought to light by operating incidents, the aim of these being to benefit from the experience gained

  3. Establishment of quality assessment standard for mammographic equipment: evaluation of phantom and clinical images

    International Nuclear Information System (INIS)

    Lee, Sung Hoon; Choe, Yeon Hyeon; Chung, Soo Young

    2005-01-01

    The purpose of this study was to establish a quality standard for mammographic equipment Korea and to eventually improve mammographic quality in clinics and hospitals throughout Korea by educating technicians and clinic personnel. For the phantom test and on site assessment, we visited 37 sites and examined 43 sets of mammographic equipment. Items that were examined include phantom test, radiation dose measurement, developer assessment, etc. The phantom images were assessed visually and by optical density measurements. For the clinical image assessment, clinical images from 371 sites were examined following the new Korean standard for clinical image evaluation. The items examined include labeling, positioning, contrast, exposure, artifacts, collimation among others. Quality standard of mammographic equipment was satisfied in all equipment on site visits. Average mean glandular dose was 114.9 mRad. All phantom image test scores were over 10 points (average, 10.8 points). However, optical density measurements were below 1.2 in 9 sets of equipment (20.9%). Clinical image evaluation revealed appropriate image quality in 83.5%, while images from non-radiologist clinics were adequate in 74.6% (91/122), which was the lowest score of any group. Images were satisfactory in 59.0% (219/371) based on evaluation by specialists following the new Korean standard for clinical image evaluation. Satisfactory images had a mean score of 81.7 (1 S.D. =8.9) and unsatisfactory images had a mean score of 61.9 (1 S.D = 11). The correlation coefficient between the two observers was 0.93 (ρ < 0.01) in 49 consecutive cases. The results of the phantom tests suggest that optical density measurements should be performed as part of a new quality standard for mammographic equipment. The new clinical evaluation criteria that was used in this study can be implemented with some modifications for future mammography quality control by the Korean government

  4. Performance and quality control of nuclear medicine instrumentation

    International Nuclear Information System (INIS)

    Paras, P.

    1981-01-01

    The status and the recent developments of nuclear medicine instrumentation performance, with an emphasis on gamma-camera performance, are discussed as the basis for quality control. New phantoms and techniques for the measurement of gamma-camera performance parameters are introduced and their usefulness for quality control is discussed. Tests and procedures for dose calibrator quality control are included. Also, the principles of quality control, tests, equipment and procedures for each type of instrument are reviewed, and minimum requirements for an effective quality assurance programme for nuclear medicine instrumentation are suggested. (author)

  5. Evaluation of the Nuclear Medicine facilities in Minas Gerais state: quality control program of equipment; Avaliacao dos servicos de Medicina Nuclear do estado de Minas Gerais: programa de controle de qualidade dos equipamentos

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Tadeu Takao Almodovar; Biancardi, Rodrigo; Rocha, Adriana Marcia Guimaraes; Ferreira, Denia Romao; Silva, Franciele Aquiles Anjos; Assuncao, Jonathan Buenos Aires; Alves, Ederson Henrique; Almeida, Ana Flavia Batista; Alves, Nathalia Fernandes; Xavier, Faber Henrique Zacarias; Gontijo, Rodrigo Modesto Gadelha; Mamede, Marcelo, E-mail: mamede.mm@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN), Belo Horizonte, MG (Brazil); Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento Anatomia e Imagem

    2017-11-01

    With the reformulation of the CNEN-NN-3.05 standard in December 2013, Brazil's Nuclear Medicine (NMS) services have to perform a greater number of quality controls for SPECT and PET equipment. However, little is known about the reality of the quality control programs of these services regarding the application of the new standard. Thus, in this context, the objective of the present study was to evaluate the quality control program of MNSs in the state of Minas Gerais. All NMSs in the state of Minas Gerais were invited to participate in the project. Of these, 34.48% (20 facilities) agreed to participate in the project, 50.00% (29 facilities) did not respond to the invitation and 15.52%(9 facilities) declined their participation. Thus, as of November 2015, 20 SPECT and 2 PET/CT equipment were evaluated for the performance of the quality control tests recommended by the new CNEN standard. The phantoms required for the evaluation came from the Laboratory of Dosimetry and Quality Control of UFMG. Even with the deadlines set by CNEN for the implementation of the quality control program in the NMSs, more than 50% of the evaluated services did not implement the quality controls, and the absence of specific phantoms is the main reason for the failure. Among the problems found in the installations, the most critical were: collimators with no conditions of use in the clinical routine, linearity problems of the evaluated image and values of image uniformity superior to the limits of acceptance. Problems in the uniformity and linearity of the image found directly impacted the performance of other tests, such as spatial resolution, SPECT performance, among others. In a general way, the NMSs in the state of Minas Gerais evaluated with the present study are in clinical feasible conditions. (author)

  6. Quality assurance grading of conventional equipment at nuclear power station

    International Nuclear Information System (INIS)

    Li Ping; Li Shichang

    2006-01-01

    Equipment QA grading with the systematic and standardized approach will benefit the concerned organizations by effective allocating of limited resources to guarantee the quality of essential equipment. This paper presents a new quality assurance grading system for the convention systems/equipment of nuclear power station, which is operative and at the same time could help the owner to allot resource reasonably through the analysis of the purpose of grading and the experience and lessons of LINGAO Phase I project. (authors)

  7. New approach to equipment quality evaluation method with distinct functions

    Directory of Open Access Journals (Sweden)

    Milisavljević Vladimir M.

    2016-01-01

    Full Text Available The paper presents new approach for improving method for quality evaluation and selection of equipment (devices and machinery by applying distinct functions. Quality evaluation and selection of devices and machinery is a multi-criteria problem which involves the consideration of numerous parameters of various origins. Original selection method with distinct functions is based on technical parameters with arbitrary evaluation of each parameter importance (weighting. Improvement of this method, presented in this paper, addresses the issue of weighting of parameters by using Delphi Method. Finally, two case studies are provided, which included quality evaluation of standard boilers for heating and evaluation of load-haul-dump (LHD machines, to demonstrate applicability of this approach. Analytical Hierarchical Process (AHP is used as a control method.

  8. Advantages of a program of quality control in the nuclear medicine equipment; Ventajas de un programa de control de calidad en los equipos de medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Trujillo Z, F.E.; Argumosa, E. [Departamento de Medicina Nuclear del Instituto Nacional de Cancerologia, Tlalpan, Mexico D.F. (Mexico); Herrera R, M.R. [Hospital Infantil de Mexico ' Federico Gomez' , Mexico D.F. (Mexico)

    2007-07-01

    In Nuclear Medicine more 90% of the entirety of the carried out procedures its are with diagnostic ends where it is acquired one or several images. This makes indispensable to have an appropriate operation of the dedicated equipment to produce images and also of those non former images, as the activity caliper, to assure an appropriate quality diagnoses not from the images and the correct dose administration to the patient. In this work the main calibrations that should be carried out and an example of the program of quality control of a gamma camera mark Siemens and model E.CAM are presented. Considerations that should take as for the radiological protection are exposed. Comments on the parameters that correct the required calibrations and the images taken place by an operation or inadequate calibrations are included. In conclusion, the necessity of a program that it contains as minimum the quality control of the gamma cameras and of the activity caliper, having as main advantages a good image quality diagnoses and to minimize the dose imparted the patient are exposed. (Author)

  9. The regulatory maze of quality control

    International Nuclear Information System (INIS)

    Stone, T.I.

    1987-01-01

    The appropriateness of specific procedures within a quality control program becomes difficult to assess when an attempt is made to collate all of the available information. This task is discussed from the perspective of the Joint Commission (JCAH Accreditation Manual), HHS(quality assurance program recommendations), equipment manufacturers maintenance schedules, and radiology administrative cost concerns

  10. Development of quality control procedures at a new radiation therapy centre

    International Nuclear Information System (INIS)

    Cooper, A.

    1999-01-01

    Before patients can be treated with radiation therapy, the radiation therapist must be certain that the equipment is functioning within specified parameters. When commencing a new service, introducing appropriate Quality Control procedures on all equipment can be a major accomplishment. At the North Queensland Oncology Service, the Radiation Therapists are responsible for the daily Quality Control on all the radiation therapy equipment. The documentation and procedures were developed by radiation therapists to ensure that all machine parameter discrepancies would be detected before a patient was treated. Monthly Quality Control is the responsibility of the Physics Department. These are carried out on the bi-weekly service days rostered for each linear accelerator and monthly for the simulator. Ongoing Quality Control and Maintenance Meetings ensures reporting and feedback is ongoing between the Radiation Therapists and Physicists. All other liaising is done through the Deputy Chief Radiation Therapist and Senior Physicist. Copyright (1999) Australian Institute of Radiography

  11. Obtention and application of recovery coefficients in SUV values to quality control in PET equipment

    International Nuclear Information System (INIS)

    Oliveira, Cássio Miri; Sá, Lídia V. de; Santana, Priscila do Carmo; Mamede, Marcelo; Silva, Teógenes A. da

    2017-01-01

    The functional imaging technique Positron Emission Tomography (PET) using the radiopharmaceutical fluorodeoxyglucose ("1"8F-FDG) has been demonstrated an important role in the diagnosis and staging of cancer tumors. However, the standard uptake values (SUV) quantification of a 'lesion' or a hot spot is influenced by partial volume effects (PVE). This is particularly important for evaluating solid tumour response to therapy, where SUV quantification could indicate treatment efficiency. The objective of this study was to evaluate the efficiency of "1"8F-FDG uptake correction in two image quantification modes (SUVmaximum and SUVmedium) through recovery coefficients (RC) application. The NEMA/IEC Body Phantom simulator was used and tested for an activity ratio lesion to background of 4:1, and at different acquisition times. The images quantification was performed with OsiriX® software. The obtained RCs were applied to the phantom images. The obtained SUVmedium values corrected by RCs presented satisfactory results, demonstrating small differences (1.1% a 2.3%) in relation to previously known SUVreference values. This did not occur for corrected SUVmaximum values where differences of up to 27.0% were observed between these and SUVreference values. These results demonstrate that the PVE correction by SUVmedium can more adequate to evaluate tumor's uptake. Therefore, this parameter should be used for equipment quality control in order to evaluate the response and degree of agreement between equipment. (author)

  12. Quality assurance for radiodiagnostic equipment in Uruguay

    International Nuclear Information System (INIS)

    Cotelo, Elena D.

    2001-01-01

    Since Uruguay did not have an study on X-ray equipment, students of Radiation Protection course (RP) made this field work throughout the country. The objective is to obtain information on the number and kind of X-ray radiodiagnostic equipment. Some of the results are: there are 666 radiodiagnostic equipment. The ratio of population to equipment is 4.515 to 1 in the capital and the mean rate in the rest of the country is 4.383 to one, with a minimum of 1.707 and a maximum of 8.220. The Public Health Ministry (MSP) and the Instituciones de Asistencia Medica Colectiva (a kind of private heath assurance) (IAMC) have less equipment in the capital than in the rest of the country. The 37% of the capital population receives assistance through the IAMC , with a 42.5 % of the equipment. Uruguay except the capital has 18 districts and 17 computed tomography equipment, from which only 3 belong to the MSP. Five districts do not have any. In Montevideo, there are 11.500 females over forty years of age per X-ray mammography equipment, and this relation in the rest of the country is 13.900. There are 21 X-ray Interventional radiology equipment, 16 of them are in the capital. Is from relating the radiodiagnostic equipment, the population and the procedures, that quality assistance indicators emerge. This owns high importance on the way to create a RP National Programme. (author)

  13. Specific developed phantoms and software to assess radiological equipment image quality

    International Nuclear Information System (INIS)

    Verdu, G.; Rodenas, F.

    2011-01-01

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be automatized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques, etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (mAs). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (author)

  14. Specific developed phantoms and software to assess radiological equipment image quality

    Energy Technology Data Exchange (ETDEWEB)

    Verdu, G., E-mail: gverdu@iqn.upv.es [Universidad Politecnica de Valencia (Spain). Dept. de Ingenieria Quimica y Nuclear; Mayo, P., E-mail: p.mayo@titaniast.com [TITANIA Servicios Teconologicos, Valencia (Spain); Rodenas, F., E-mail: frodenas@mat.upv.es [Universidad Politecnica de Valencia (Spain). Dept. de Matematica Aplicada; Campayo, J.M., E-mail: j.campayo@lainsa.com [Logistica y Acondicionamientos Industriales S.A.U (LAINSA), Valencia (Spain)

    2011-07-01

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be automatized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques, etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (mAs). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (author)

  15. Nuclear safety: a large scale quality audit of pressurized equipment

    International Nuclear Information System (INIS)

    Faudon, Valerie

    2016-01-01

    This article notably refers to, quotes and comments a hearing organised by the French Public Office for the Assessment Scientific and Technological Choices (OPECST) on the issue of safety of pressurized equipment in nuclear reactors, and which gathered the main concerned actors (Areva, EDF, IRSN, ASN) to have an overview of quality controls in AREVA NP fabrication plants. Two different issues have been addressed: a technical metallurgical issue related to some boiler-making parts, and an issue related to quality assurance. These issues concern different older reactors (Fessenheim for example) as well as new ones (EPR Flamanville). The article indicates the different measures planned, envisaged or already implemented by the concerned actors in order to improve knowledge in the boiler-making industry, and to ensure a better quality

  16. Some observations about quality control tests of Spect

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.

    1987-01-01

    Some observations about quality control tests done in the tomographic system of Heart Institute are described. Among the tests, the traditional test of quality control with scintillation camera and the specific test for tomography systems are induced. The traditional tests are essential, but not sufficient for evaluating the Spect equipment and the specific tests have been effectuated in controlled conditions. (C.G.C.) [pt

  17. Comparative tests of bench equipment for fuel control system testing of gas-turbine engine

    Science.gov (United States)

    Shendaleva, E. V.

    2018-04-01

    The relevance of interlaboratory comparative researches is confirmed by attention of world metrological community to this field of activity. Use of the interlaboratory comparative research methodology not only for single gages collation, but also for bench equipment complexes, such as modeling stands for fuel control system testing of gas-turbine engine, is offered. In this case a comparative measure of different bench equipment will be the control fuel pump. Ensuring traceability of measuring result received at test benches of various air enterprises, development and introduction of national standards to practice of bench tests and, eventually, improvement of quality and safety of a aircraft equipment is result of this approach.

  18. Quality control: comparison of images quality with screen film system and digital mammography CR

    International Nuclear Information System (INIS)

    Alvarenga, Frederico L.; Nogueira, Maria do Socorro

    2008-01-01

    The mammography screen film system should be used as part of processing chemicals, revelation process, equipment and this system has have a progressive replacing by the digital technology Full Field Digital Mammography FFDM, Computed Radiography (CR) Mammography and hardcopy. This new acquisition process of medical images has improved radiology section; however it is necessary efficient means for evaluating of the quality parameters. It should be considered taking into account the adaptation of the existent equipment and that procedures adopted for the exam, as well the adaptation of the new mammography films, the radiologist view box constitutes a part of the quality control program. This program aims at obtaining radiography with good quality that allows obtaining more information for the diagnosis and decreases the patient dose. For evaluation the quality image, this article is focused on presenting the differences regarding the acquired images through simulator mammography radiographic PMMA (Poly methyl methacrylate) in CR Mammography system and screen film system. The tests were accomplished at the same equipment of Mammography with the Automatic Exposure Control using a tension of 28 kV for both systems. The quality tests evaluated the spatial resolution, the own structures of the phantom, artifacts, optical density and contrast with conventional and laser films by mammography system. The installation for the accomplishment of the test has a quality control program. The evaluation was based on the pattern developed by the competent organ of the State of Minas Gerais. In this study, it was verified that the suitable Phantom Mama used by the Brazilian School of Radiology for conventional mammography did not obtain satisfactory result for Spatial Resolution in the digital mammography system CR. The final aim of this work is to obtain parameters to characterize the reference phantom quality image in an objective way. These parameters will be used to compare

  19. METHODOLOGY OF DETERMINATION OF QUALITY INDEX OF MAINTENANCE SERVICE SYSTEM OF POWER EQUIPMENT OF TRACTION SUBSTATIONS

    Directory of Open Access Journals (Sweden)

    O.O. Matusevych

    2016-03-01

    information was further developed. The author offers a number of options at first time. There are version of the document formalized quality evaluation of power equipment of traction substations by experts; expression to define the integral Quality systems maintenance and electrical power P TS, which is absent in the standard system maintenance and P; matrix of quality system with regard to steps (methods and ways of increasing service quality electrical power control systems. This method makes it possible to conduct an expert assessment of the maintenance system and to predict and select the option rational system of quality improvement and maintenance of power equipment of traction substations considering not only technical but also organizational, legal, financial and economic measures. Practical value. Improvement on electrified railways of Ukraine quality management system maintenance and P TS will improve the efficiency and quality of maintenance of power equipment and provide TA prevent or reduce the severity of possible equipment failures. Based on the relationships matrix components as systems maintenance and electrical power P TP were formed expressions calculating quality indices of integrated systems with directions and stages for specific equipment and systems in general. It was determined that an increase in the quality and maintenance of electrical PR, the rate of change of the measured value at step k during operation is reduced while the standard deviation parameter is also reduced, and the probability of electrical TA increases.

  20. Quality Control in Diagnostic Radiology in the Netherlands (invited paper)

    International Nuclear Information System (INIS)

    Zoetelief, J.

    1998-01-01

    Application of the general principles of radiation protection to medical diagnostic radiology implies that each procedure using X rays or radionuclides is to be justified and optimised. Optimisation in diagnostic radiology implies that the radiation burden to the patient should be as low as possible, but compatible with the image quality necessary to obtain an adequate diagnosis or to guide treatment. Quality control of equipment is a prerequisite for achieving optimisation in diagnostic radiology. This was especially recognised for mammography as employed for breast cancer screening. Existing legislation in the Netherlands includes only a few criteria for equipment used in diagnostic radiology. In addition, the criteria are not all operational and measurement methods are lacking. Therefore, upon the initiative of the Dutch Ministry of Health, Welfare and Sports, the relevant professional societies, in collaboration with the former TNO Centre for Radiological Protection and Dosimetry, formulated eleven guidelines for quality control of equipment used in diagnostic radiology, including test procedures, test frequencies and limiting values. The implementation of quality control of equipment was included in the 1984 European Directive (84/466/Euratom) laying down basic measures for the radiation protection of persons undergoing medical examination or treatment. In the most recent European Directive on medical exposure (97/43/Euratom) the importance of quality control is stressed. In addition, the latter EC directive proposes the use of diagnostic reference levels for limiting the risks for patients undergoing diagnostic radiology. In the Netherlands preliminary reference levels for various procedures employed in diagnostic radiology are suggested. Finally, methods applied in the Netherlands for assessment of image quality are discussed. (author)

  1. Obtention and application of recovery coefficients in SUV values to quality control in PET equipment

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Cássio Miri; Sá, Lídia V. de; Santana, Priscila do Carmo; Mamede, Marcelo; Silva, Teógenes A. da, E-mail: cassio.miri@unifesp.br, E-mail: lidia@ird.gov.br, E-mail: mamede.mm@gmail.com, E-mail: silvata@cdtn.br [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Departmento de Diagnose por Imagem; Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-11-01

    The functional imaging technique Positron Emission Tomography (PET) using the radiopharmaceutical fluorodeoxyglucose ({sup 18}F-FDG) has been demonstrated an important role in the diagnosis and staging of cancer tumors. However, the standard uptake values (SUV) quantification of a 'lesion' or a hot spot is influenced by partial volume effects (PVE). This is particularly important for evaluating solid tumour response to therapy, where SUV quantification could indicate treatment efficiency. The objective of this study was to evaluate the efficiency of {sup 18}F-FDG uptake correction in two image quantification modes (SUVmaximum and SUVmedium) through recovery coefficients (RC) application. The NEMA/IEC Body Phantom simulator was used and tested for an activity ratio lesion to background of 4:1, and at different acquisition times. The images quantification was performed with OsiriX® software. The obtained RCs were applied to the phantom images. The obtained SUVmedium values corrected by RCs presented satisfactory results, demonstrating small differences (1.1% a 2.3%) in relation to previously known SUVreference values. This did not occur for corrected SUVmaximum values where differences of up to 27.0% were observed between these and SUVreference values. These results demonstrate that the PVE correction by SUVmedium can more adequate to evaluate tumor's uptake. Therefore, this parameter should be used for equipment quality control in order to evaluate the response and degree of agreement between equipment. (author)

  2. Development of a dosimetric system for dental X-ray equipment quality control

    International Nuclear Information System (INIS)

    Melo, Francisco Almeida de

    2002-08-01

    An electronic instrument with digital readout was designed and constructed to provide fast, simple and non-invasive measurements of X-ray dental equipment parameters. This instrument is capable of evaluating the entrance dose, exposure time, tube voltage (kVp) and beam filtration. It consists of a set of five photodiodes connected each one in the photocurrent mode to the input of a designed integrating electrometer. Three of the detectors are fixed under aluminium filters with different thicknesses, one is fixed under a 0.3 mm copper filter and the other has no filtration. The readings of the three detectors under aluminium filters and of the bare detector permit the determination of the half-value layer, which is used to calculate the beam filtration. The ratio between the readings of the detector below the copper filter and the one without filtration is used to determine the tube voltage. The signal produced by the detector without filter is used to evaluate the patient entrance dose, and to active an electronic timer for measuring the real exposure time. The tests and calibration of the instrument in different voltages in the 59 - 70kVp range, showed that its response is both stable and reproducible to within 1%. The instrument response was compared to the one from a commercial non-invasive X-ray test equipment (Gammex RMI Multifunction kVp meter). The results showed that the response of the developed instrument is in good agreement with the RMI meter which is the standard equipment for such measurements. These results indicate that the dosimetric system is suitable for use in Dental Quality Assurance Programs. (author)

  3. A quality control manual for oral radiology

    International Nuclear Information System (INIS)

    Peixoto, J.E.; Ferreira, R.S.; Bessa, S.O.; Domingues, C.; Gomes, C.A.; Oliveira, S.L.G.; Ortiz, J.A.P.

    1988-01-01

    A quality control manual for oral radiology is showed. The X-ray equipment used for this activity is described, such as the X-ray tube, collimator. The high tension in X-ray tube, the spectra, the quality and the quantity of radiation and the X-ray intensity are also analysed. (C.G.C.) [pt

  4. Quality control for some digital fluoroscopy equipment used in Sudan

    International Nuclear Information System (INIS)

    Nayledam, A. I.

    2009-07-01

    The aim of this work was to perform quality control (QC) for six digital fluoroscopy units used for cardiovascular and interventional radiology procedures. Measurement were based on the QC protocol developed in the framework of European Commission (EU) DIMOND111 project. Measurement made included: beam quality (half-value layer, HVL), peak tube voltage (kVp) accuracy, automatic exposure control (Aec) and patient dose in terms of entrance surface air kerma rate plus image intensifier input air kerma rate. Dose measurements were made using Calibrated dose rate meter. Field limitation and source to skin distant measurement in addition to evaluation radiation protection tools for occupation exposure were performed. Image quality was evaluated in terms of spatial resolution and Contrast detail detectability. Patient dose measurements was performed using polymethylmethacrylate (PMMA) patient equivalent phantom whereas image quality was assessed using Haunter Type 53 spatial frequency grating and TO10 contrast detail phantom. The results show that the measured HVL and peak tube voltage were within the recommended limits of 10% in four fluoroscopy units. Entrance surface air kerma rate measured ranged from 6.1 to 250 mGy/min for fluoroscopy units operated in pulsed, continuous and cine mode of operation. These results were obtained using varying thicknesses of PMMA phantom. Most values are in reasonable agreement with internationally established reference levels with exception to one fluoroscopy unit where doses were remarkably high. Field limitation and minimum source to skin distance were well within the recommended limits of 30 cm for all fluoroscopy units. The limiting resolution was ranged from 1.0 to 2.2 Lp /mm for image intensifier field diameters between 7 ad 23 cm. The results of present study can be used as baseline for future quality assurance measurements. (Author)

  5. Challenges in setting up quality control in diagnostic radiology ...

    African Journals Online (AJOL)

    Journal Home > Vol 24, No 4 (2015) >. Log in or ... Quality control (QC) on diagnostic radiology equipment form part of the fundamental requirements for the ... Inadequate cooperation by facilities management, lack of QC equipment and insufficient staff form the major challenges in setting up QC in the facilities under study.

  6. Quality control, mean glandular dose estimate and room shielding calculation in mammography

    International Nuclear Information System (INIS)

    Rakotomalala, H.M.

    2014-01-01

    This study focuses in the importance of Radiation Protection in mammography. A good control of the radiological risk depends on the dose optimization, room shielding calculation and the quality of equipment. The work was carried out in the three private medical centers called A, B, and C. Dosimetry estimates were made on the equipment of the three centers. Values has been compared with the Diagnostic Reference Levels established by the International Atomic Energy Agency (IAEA). Conformity control of the radiological devices has also been done with the Mammographic Quality Control Kit of the INSTN-Madagascar. Verifications of shields of the room containing the mammography equipment were done by theoretical calculations using the method provided by NCRP 147. [fr

  7. Computer-supported quality control in X-ray diagnosis

    International Nuclear Information System (INIS)

    Maier, W.; Klotz, E.

    1989-01-01

    Quality control of X-ray facilities in radiological departments of large hospitals is possible only if the instrumentation used for measurements is interfaced to a computer. The central computer helps to organize the measurements as well as analyse and record the results. It can also be connected to a densitometer and camera for evaluating radiographs of test devices. Other quality control tests are supported by a mobile station with equipment for non-invasive dosimetry measurements. Experience with a computer-supported system in quality control of film and film processing is described and the evaluation methods of ANSI and the German industrial standard DIN are compared. The disadvantage of these methods is the exclusion of film quality parameters, which can make processing control almost worthless. (author)

  8. Evaluation tests of the Instrumentation and Control equipment to use in nuclear power plants: its contribution to the improvement and quality certification of the Brazilian equipment

    International Nuclear Information System (INIS)

    Menezes, R.H.M. de; Peluso, M.A.V.

    1984-01-01

    This work presents the procedures used to evaluate Instrumentation Control equipment and reports the experience of integration among instrument user, manufacturer and test institution. It covers tests for equipments for conventional user and for specific application in Nuclear Power Stations. (Author) [pt

  9. US quality control in Italy: present and future

    Science.gov (United States)

    Balbis, S.; Musacchio, C.; Guiot, C.; Spagnolo, R.

    2011-02-01

    US diagnostic equipments are widely diffused in Italy but, in spite of recommendations (e.g. ISPESL-Ministry of Health (1999) and SIRM (Società Italiana di Radiologia Medica, 2004), US quality controls are restricted to only a few public sanitary structure and a national (or even regional) quality assurance program for testing the performances of the US equipments is still missing. A joint Research Centre among the three Piedmontese Universities and INRIM, partially funded by Regione Piemonte, has been established in 2009 as Reference Centre for Medical Ultrasounds (CRUM). In addition to research, development and training tasks, the Centre aims at the local diffusion of the quality assurance in clinical US equipments. According to data from the Ministry of Health (2006), around 7 % of the Italian US diagnostic equipments (946 over 13526) are located in Piedmont: mostly (75.6%) in public hospitals, 9.3 % in conventionated hospitals, 4.3% in public and 10.8% in private territorial structures. The goal is the provision of a regional database, which progressively includes data related to acceptance test, status and QC tests and maintenance, in order to drive equipment turnover and carefully monitoring the overall equipment efficiency. Moreover, facilities are available at CRUM for monitoring both beam geometry and acoustic power and performing quantitative assessment of the delivered energy intensity.

  10. Quality audits of the remote-controlled automatically-driven gamma ray afterloading equipment used in brachytherapy in the Czech Republic

    International Nuclear Information System (INIS)

    Zackova, H.; Horakova, I.

    2001-01-01

    To reach safety and precise application of ionisation radiation to patients Atomic act declares, in its Article no. 7, requirements for medical exposure. There are also given -among others -the demands to i nstall the quality assurance programmes (QA) for medical actions and functions . Since 1997, when the act has been adopted, a set of five Recommendations of State Office for Nuclear Safety (SONS ) for radiotherapy has been prepared to instruct users how to prepare quality control system (i.e. system of tests required by of the regulation no.184/1997 Sb. -acceptance, status and constancy tests) for main types of sources used in radiotherapy for treatment of the patients. Among them also the Recommendation on QA in brachytherapy has been issued by SONS in 1998. National Radiation Protection Institute (NRPI) has been performing the regular in situ quality audits in which the chosen parameters (which could seriously influence the dose to the patients -i.e. absorbed dose, main geometrical and radiation parameters etc ) are independently checked by the NRPI experts. System of Quality Audits on the sources used in teletherapy has been introduced in 1997 and at present time they are smoothly carried out according the SONS's demands. This work describes the process of installing of the Quality Audit system on brachytherapy. The work described here forms the only part of the activities, which have been carrying out by the department of dosimetry gamma and X-rays of NRPI to support supervisions of SONS in the field of radiation protection in radiotherapy .Quality audits in brachytherapy will extend the possibilities of NRPI. The Methods NRPI 43-01.30 prepared by NRPI could be used as documentation for all types of test which are at present time required by Czech legislation for the remote-controlled automatically-driven gamma-ray afterloading equipment used in brachytherapy. (authors)

  11. A study on enforcement effects of radiation safety control regulations for diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Sung, Mo IL; Park, Myeong Hwan; Kwon, Duk Moon; Lee, Joon IL

    1999-01-01

    The purposes of this study are to analyze the realities after enforcements of safety control regulations for diagnostic X-ray equipment and to suggest means for an improvement of low radiation safety control. A questionnaire survey for medical radiologic technologists was carried out to determine enforcement effects of the safety control regulations. The results of analysis from the survey are as follows. That is, most of he respondents realized the importance of the radiation safety control system, but about a half of them revealed that regulations were not well observed in accordance with their purposes. Only 43.9 percent of the respondents took an active part in quality control of radiation. And responsibility, sex, age, and knowledge for safety control were important indicators for observations of the regulations. Training for the safety control regulations are needed to ensure safety control and proper usage of diagnostic X-ray equipment. And management of organizations using diagnostic X-ray equipment have to understand and stress the importance of radiation safety control system. (author)

  12. Suggestion for improvement of PET quality control tests in Brazil

    International Nuclear Information System (INIS)

    Ferreira, Fernanda C.L.; Magalhaes, Cinthia M.S.; Souza, Divanizia N.

    2009-01-01

    Nowadays nuclear medicine has a considerable importance among the other medical specialties. This medical specialty utilizes high-tech equipment for imaging in the diagnosis, obtaining information on the clinical functionality of organs and systems of the human body through the use of radioisotopes . In view of the importance of guaranteeing the image quality in SPECT and PET systems, enabling patients not repeat exams due to lack of quality control of equipment used in nuclear medicine, this paper aims to present a possible suggestion to update the quality control tests needed for quality assurance of nuclear medicine services. They were considered the requirements of the National Commission of Nuclear Energy (CNEN) and the National Health Surveillance Agency (ANVISA) in Brazil. The minimum requirements to be defined for inclusion of quality control tests on PET in the standard CNEN are extremely important because they will guide the evaluation of PET systems, determining the quality control tests to be performed. And those tests for PET will be a regulatory requirement by the CNEN and ANVISA. As the National Health Surveillance Agency has already publication of RDC 38 with recommendations for services of nuclear medicine. This study will continue with evaluation of PET systems and presenting the tests of quality control with additional objects and simulators to ensure safety in PET systems have not standardized in nuclear medicine services in Brazil. (author)

  13. External quality audit programmes for radiotherapy dosimetry and equipment

    International Nuclear Information System (INIS)

    Thwaites, D.I.

    1997-01-01

    It is widely accepted that individual radiotherapy centres should have in place a comprehensive quality assurance programme on all the necessary steps for the delivery of safe accurate treatment. As regards the performance of radiotherapy equipment and dosimetry, the most widely used process of external checking has been dosimetry intercomparison, comparing independently measured doses to locally stated doses in a variety of conditions. These have been at a number of different levels: from basic beam calibration; up to and including exercises employing anatomic or pseudo-anatomic phantoms and incorporating tests of treatment planning equipment and procedures. Some of these have been one-off exercises, whilst others are continuing, or have given rise to on-going quality audit programmes on a national (or wider) basis. A number of these have evolved, or are evolving, into audits which include external checking of the achievement of standards in performance of treatment equipment, as well as in the dosimetry in each institution involved. The principles and methodologies of the various types of external checking programmes for treatment equipment and dosimetry are reviewed, covering the experimental approaches and the tolerances applied. What is included in a given programme will, of necessity, depend on the resources available and the purpose of the exercise. Methods and tolerances must be matched to endpoint. Tolerance levels must take into account the experimental uncertainties of the measurement methods employed. Finally, external audit can only be used to complement, and in conjunction with, institutional quality assurance programmes and not as a substitute for them

  14. 38 CFR 17.155 - Minimum standards of safety and quality for automotive adaptive equipment.

    Science.gov (United States)

    2010-07-01

    ... safety and quality for automotive adaptive equipment. 17.155 Section 17.155 Pensions, Bonuses, and... Minimum standards of safety and quality for automotive adaptive equipment. (a) The Under Secretary for... officials that it meets implicit standards of safety and quality adopted by the industry or as later...

  15. Organizing quality control programmes

    International Nuclear Information System (INIS)

    Hjardemaal, O.

    1989-01-01

    When procuring new equipment, performance and safety should be specified, if possible by reference to international standards. Some of the characteristics of the International Electrotechnical Commission (IEC) standard for X-ray generators, in particular the accuracy of the operating data, are described. The quality control tests to be performed after installation comprise acceptance test, status test and constancy test. The first two involve absolute measurements and will be the responsibility of physicists or engineers. Apparently limiting values stipulated by users are a factor of two lower than the limits of the IEC standard. By means of an example it is shown that modern X-ray generators can meet the lower limits of the users without problems. In order to obtain optimum initial quality when procuring new equipment operating data, limiting values must be specified and must be verified by acceptance testing, etc. However, in many countries physicists and engineers are not available for this job. A relatively uncomplicated test object can be used by radiographers for checks on fluoroscopic systems. The findings from such tests in Denmark are compared with other published findings and good agreement is found. Therefore it is proposed that such uncomplicated tests could form the basis for quality evaluation. (author)

  16. 30 CFR 250.806 - Safety and pollution prevention equipment quality assurance requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Safety and pollution prevention equipment... Gas Production Safety Systems § 250.806 Safety and pollution prevention equipment quality assurance... install only certified safety and pollution prevention equipment (SPPE) in wells located on the OCS. SPPE...

  17. Application of quality assurance program to safety related aging equipment or components

    International Nuclear Information System (INIS)

    Papaiya, N.C.

    1990-01-01

    This paper addresses how quality assurance programs and their criteria are applied to safety related and aging equipment or components used in commercial nuclear plant applications. The QA Programs referred to are 10CFR50 Appendix B and EPRI NP-5652. The QA programs as applicable are applied to equipment/component aging qualification, preventive maintenance, surveillance testing and procurement engineering. The intent of this paper is not the technical issues, methods and research of aging. The paper addresses QA program's application to age-related equipment or components in safety related applications. Quality Assurance Program 10CFR50 Appendix B applies to all safety related aging components or equipment related to the qualification program and associated preventive maintenance and surveillance testing programs. Quality Assurance involvement with procurement engineering for age-related commercial grade items supports EPRI NP-5652 and assures that the dedicated OGI is equal to the item purchased as a basic component to 10CFR50 Appendix B requirements

  18. Research on the Reliability Testing of Electrical Automation Control Equipment

    OpenAIRE

    Yongjie Luo

    2014-01-01

    According to the author’s many years’ work experience, this paper first discusses the concepts of electrical automation control equipment reliability testing, and then analyzes the test method of electrical automation control equipment reliability testing, finally, on this basis, this article discusses how to determine the reliability test method of electrical automation control equipment. Results of this study will provide a useful reference for electrical automation control equipment reliab...

  19. Quality Risk Management: Putting GMP Controls First.

    Science.gov (United States)

    O'Donnell, Kevin; Greene, Anne; Zwitkovits, Michael; Calnan, Nuala

    2012-01-01

    This paper presents a practical way in which current approaches to quality risk management (QRM) may be improved, such that they better support qualification, validation programs, and change control proposals at manufacturing sites. The paper is focused on the treatment of good manufacturing practice (GMP) controls during QRM exercises. It specifically addresses why it is important to evaluate and classify such controls in terms of how they affect the severity, probability of occurrence, and detection ratings that may be assigned to potential failure modes or negative events. It also presents a QRM process that is designed to directly link the outputs of risk assessments and risk control activities with qualification and validation protocols in the GMP environment. This paper concerns the need for improvement in the use of risk-based principles and tools when working to ensure that the manufacturing processes used to produce medicines, and their related equipment, are appropriate. Manufacturing processes need to be validated (or proven) to demonstrate that they can produce a medicine of the required quality. The items of equipment used in such processes need to be qualified, in order to prove that they are fit for their intended use. Quality risk management (QRM) tools can be used to support such qualification and validation activities, but their use should be science-based and subject to as little subjectivity and uncertainty as possible. When changes are proposed to manufacturing processes, equipment, or related activities, they also need careful evaluation to ensure that any risks present are managed effectively. This paper presents a practical approach to how QRM may be improved so that it better supports qualification, validation programs, and change control proposals in a more scientific way. This improved approach is based on the treatment of what are called good manufacturing process (GMP) controls during those QRM exercises. A GMP control can be considered

  20. Quality assurance, quality control and quality audit in diagnostic radiology

    International Nuclear Information System (INIS)

    Vassileva, J.

    2009-01-01

    Full text:The lecture aims to present contemporary view of quality assurance in X-Ray diagnosis and its practical realization in Bulgaria. In the lecture the concepts of quality assurance, quality control and clinical audit will be defined and their scope will be considered. An answer of the following questions will be given: why is it necessary to determine the dose of patient in X-ray studies, what is the reference dose level and how it is used for dosimetric quantity which characterized the patient's exposure in X-ray, mammography and CT scans and how they are measured, who conducted the measurement and how to keep the records, what are the variations of doses in identical tests and what defines them? The findings from a national survey of doses in diagnostic radiology, conducted in 2008-2009 and the developed new national reference levels will be presented. The main findings of the first tests of radiological equipment and the future role of quality control as well as the concept of conducting clinical audit and its role in quality assurance are also presented. Quality assurance of the diagnostic process with minimal exposure of patients is a strategic goal whose realization requires understanding, organization and practical action, both nationally and in every hospital. To achieve this the important role of education and training of physicians, radiological technicians and medical physicists is enhanced

  1. Laser-based measuring equipment controlled by microcomputer

    International Nuclear Information System (INIS)

    Miron, N.; Sporea, D.; Velculescu, V.G.; Petre, M.

    1988-03-01

    Some laser-based measuring equipment controlled by microcomputer developed for industrial and scientific purposes are described. These equipments are intended for dial indicators verification, graduated rules measurement, and for very accurate measurement of the gravitational constant. (authors)

  2. Performance test of nutrient control equipment for hydroponic plants

    Science.gov (United States)

    Rahman, Nurhaidar; Kuala, S. I.; Tribowo, R. I.; Anggara, C. E. W.; Susanti, N. D.

    2017-11-01

    Automatic control equipment has been made for the nutrient content in irrigation water for hydroponic plants. Automatic control equipment with CCT53200E conductivity controller to nutrient content in irrigation water for hydroponic plants, can be used to control the amount of TDS of nutrient solution in the range of TDS numbers that can be set according to the range of TDS requirements for the growth of hydroponically cultivated crops. This equipment can minimize the work time of hydroponic crop cultivators. The equipment measurement range is set between 1260 ppm up to 1610 ppm for spinach plants. Caisim plants were included in this experiment along with spinach plants with a spinach plants TDS range. The average of TDS device is 1450 ppm, while manual (conventional) is 1610 ppm. Nutrient solution in TDS controller has pH 5,5 and temperature 29,2 °C, while manual is pH 5,6 and temperature 31,3 °C. Manually treatment to hydroponic plant crop, yields in an average of 39.6 grams/plant, greater than the yield of spinach plants with TDS control equipment, which is in an average of 24.6 grams / plant. The yield of caisim plants by manual treatment is in an average of 32.3 grams/crop, less than caisim crop yields with TDS control equipment, which is in an average of 49.4 grams/plant.

  3. Web-based X-ray quality control documentation.

    Science.gov (United States)

    David, George; Burnett, Lou Ann; Schenkel, Robert

    2003-01-01

    The department of radiology at the Medical College of Georgia Hospital and Clinics has developed an equipment quality control web site. Our goal is to provide immediate access to virtually all medical physics survey data. The web site is designed to assist equipment engineers, department management and technologists. By improving communications and access to equipment documentation, we believe productivity is enhanced. The creation of the quality control web site was accomplished in three distinct steps. First, survey data had to be placed in a computer format. The second step was to convert these various computer files to a format supported by commercial web browsers. Third, a comprehensive home page had to be designed to provide convenient access to the multitude of surveys done in the various x-ray rooms. Because we had spent years previously fine-tuning the computerization of the medical physics quality control program, most survey documentation was already in spreadsheet or database format. A major technical decision was the method of conversion of survey spreadsheet and database files into documentation appropriate for the web. After an unsatisfactory experience with a HyperText Markup Language (HTML) converter (packaged with spreadsheet and database software), we tried creating Portable Document Format (PDF) files using Adobe Acrobat software. This process preserves the original formatting of the document and takes no longer than conventional printing; therefore, it has been very successful. Although the PDF file generated by Adobe Acrobat is a proprietary format, it can be displayed through a conventional web browser using the freely distributed Adobe Acrobat Reader program that is available for virtually all platforms. Once a user installs the software, it is automatically invoked by the web browser whenever the user follows a link to a file with a PDF extension. Although no confidential patient information is available on the web site, our legal

  4. Control of equipment isolation system using wavelet-based hybrid sliding mode control

    Science.gov (United States)

    Huang, Shieh-Kung; Loh, Chin-Hsiung

    2017-04-01

    Critical non-structural equipment, including life-saving equipment in hospitals, circuit breakers, computers, high technology instrumentations, etc., is vulnerable to strong earthquakes, and on top of that, the failure of the vibration-sensitive equipment will cause severe economic loss. In order to protect vibration-sensitive equipment or machinery against strong earthquakes, various innovative control algorithms are developed to compensate the internal forces that to be applied. These new or improved control strategies, such as the control algorithms based on optimal control theory and sliding mode control (SMC), are also developed for structures engineering as a key element in smart structure technology. The optimal control theory, one of the most common methodologies in feedback control, finds control forces through achieving a certain optimal criterion by minimizing a cost function. For example, the linear-quadratic regulator (LQR) was the most popular control algorithm over the past three decades, and a number of modifications have been proposed to increase the efficiency of classical LQR algorithm. However, except to the advantage of simplicity and ease of implementation, LQR are susceptible to parameter uncertainty and modeling error due to complex nature of civil structures. Different from LQR control, a robust and easy to be implemented control algorithm, SMC has also been studied. SMC is a nonlinear control methodology that forces the structural system to slide along surfaces or boundaries; hence this control algorithm is naturally robust with respect to parametric uncertainties of a structure. Early attempts at protecting vibration-sensitive equipment were based on the use of existing control algorithms as described above. However, in recent years, researchers have tried to renew the existing control algorithms or developing a new control algorithm to adapt the complex nature of civil structures which include the control of both structures and non

  5. Quality control in nuclear fuel fabrication

    International Nuclear Information System (INIS)

    Abdelhalim, A.S.; Elsayed, A.A.; Shaaban, H.I.

    1988-01-01

    The department of metallurgy, NRC Inchass is embarking on a programme of on a laboratory scale, fuel pins containing uranium dioxide pellets are going to be produced. The department is making use of the expertise and equipment at present available and is going to utilize the new fuel pin fabrication unit which would be shortly in operation. The fabrication and testing of uranium dioxide pellets then gradually adapt them and develop, a national know how in this field. This would also involve building up of indigenous experience through proper training of qualified personnel. That are applied to ensure quality of U o 2 pellets, the techniques implemented, the equipment used and the specifications of the equipment presently available. The following parameters are subject to quality control tests: density. O/U ration, hydrogen content, microstructure, each property will be discussed, measurements related to U o 2 powders, including flow ability, bulk density, O/U ratio, bet surface area and water content will be critically discussed. Relevant tests to ensure Q C of pellets are reviewed. These include surface integrity, density, dimensions, microstructure.4 fig., 1 tab

  6. Progress in control equipment for fuel-handling machinery

    International Nuclear Information System (INIS)

    Nutting, B.A.

    1986-01-01

    The paper outlines the development of the equipment used to control the fuel-handling machinery associated with nuclear reactors, from the early electromechanical equipment, through solid-state switching logic to programmable controllers and microprocessors. The control techniques have developed along with the technology, and modern systems offer versatility, reliability and ease of design, operation and maintenance. Future trends and developments are discussed together with possible limiting factors. (author)

  7. Survey of mammography practice in Croatia: Equipment performance, image quality and dose

    International Nuclear Information System (INIS)

    Faj, D.; Stimac, D.; Ivezic, Z.; Kasabasic, M.; Ivkovic, A.; Posedel, D.; Kubelka, D.; Ilakovac, V.; Brnic, Z.; Bjelac, O.C.

    2008-01-01

    A national audit of mammography equipment performance, image quality and dose has been conducted in Croatia. Film-processing parameters, optical density (OD), average glandular dose (AGD) to the standard breast, viewing conditions and image quality were examined using TOR(MAM) test object. Average film gradient ranged from 2.6 to 3.7, with a mean of 3.1. Tube voltage used for imaging of the standard 45 mm polymethylmethacrylate phantom ranged from 24 to 34 kV, and OD ranged from 0.75 to 1.94 with a mean of 1.26. AGD to the standard breast ranged from 0.4 to 2.3 mGy with a mean of 1.1 mGy. Besides clinical conditions, the authors have imaged the standard phantom in the referent conditions with 28 kV and OD as close as possible to 1.5. Then, AGD ranged from 0.5 to 2.6 mGy with a mean of 1.3 mGy. Image viewing conditions were generally unsatisfying with ambient light up to 500 lx and most of the viewing boxes with luminance between 1000 and 2000 cd per m 2 . TOR(MAM) scoring of images taken in clinical and referent conditions was done by local radiologists in local image viewing conditions and by the referent radiologist in good image viewing conditions. Importance of OD and image viewing conditions for diagnostic information were analysed. The survey showed that the main problem in Croatia is the lack of written quality assurance/quality control (QA/QC) procedures. Consequently, equipment performance, image quality and dose are unstable and activities to improve image quality or to reduce the dose are not evidence-based. This survey also had an educational purpose, introducing in Croatia the QC based on European Commission Guidelines. (authors)

  8. Quality of mammography equipment in Health Public Network; Calidad de proceso generador de imagenes mamograficas de equipos instalados en la Red Publica de Salud

    Energy Technology Data Exchange (ETDEWEB)

    Ruberti Filha, E. M.; Pires, S. R.; Medeiros, R. B.

    2006-07-01

    In spite of the requirements of the Brazilian Regulatory Organization to ensure that quality control verifications are made in the radiological equipment, further actions should also be carried out in order to guarantee the quality of the images and of the diagnosis. This study has as its objective to analyze the failures of the image generation system using instruments to control the quality of the radiological equipment, verify the processing image conditions and, finally, classify the mammographic findings as unacceptable, suitable and acceptable. A statistical phantom was used in which the fibers and the microcalcifications were randomly positioned. The images were then read by specialists and the level of agreement was measured by the Kappa value. It was possible to check that most of the tested equipment parameters presented a good performance, although the film processing did not generate satisfactory results and caused reading difficulties. Many of the results of these reading were classified as unacceptable. Among these images, only a small percentage of them presented the fibers and microcalcifications of the sizes required by the Brazilian legislation. We concluded that it is only possible to generate good quality images if all the steps of the process are properly controlled. Therefore, it is relevant to invest in training, calibration and maintenance of the mammographic equipment. (Author)

  9. The UK market for gaseous emissions control equipment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-09-01

    The report analyses the changes in demand for gaseous emissions control equipment in the United Kingdom over the next 5 years. It discusses the factors affecting demand such as legislation reporting of environmental performance, and economic factors. It looks at environmental expenditure by UK industry. Markets are examined, for VOC abatement systems; thermal incinerators; adsorption equipment; catalytic oxidisers; absorption equipment; biological treatments; cryogenic equipment; SO{sub x} abatement equipment; wet FGD; wet dry FGD, dry scrubbers; NOx abatement systems; selective catalytic reduction; and selective non-catalytic reduction. Profiles are given of 16 leading suppliers.

  10. Radiological protection and quality control for diagnostic radiology in China

    International Nuclear Information System (INIS)

    Baorong, Yue

    2008-01-01

    Full text: There are 43,000 diagnostic departments, nearly 70,000 X-ray diagnostic facilities, 7,000 CT, 250 million for the annual total numbers of X-ray examinations, 120,000 occupationally exposed workers in diagnostic radiology. 'Basic standards for protection against ionizing radiation and for the safety of radiation sources' is promulgated on October, 2002. This basic standard follows the BSS. 'Rule on the administration of radio-diagnosis and radiotherapy', as a order of the Ministry of Health No. 46, is promulgated by Minister of Health on January 24, 2006. It includes general provisions, requirements and practice, establishment and approval of radio-diagnosis and radiotherapy services, safeguards and quality assurance, and so on. There are a series of radiological protection standards and quality control standards in diagnostic radiology, including 'radiological protection standard for the examination in X-ray diagnosis', 'radiological health protection standards for X-ray examination of child-bearing age women and pregnant women', 'radiological protection standards for the children in X-ray diagnosis', 'standards for radiological protection in medical X-ray diagnosis', 'specification for radiological protection monitoring in medical X-ray diagnosis', 'guide for reasonable application of medical X-ray diagnosis', 'general aspects for quality assurance in medical X-ray image of diagnosis', 'specification of image quality control test for the medical X-ray diagnostic equipment', 'specification of image quality assurance test for X-ray equipment for computed tomography', 'specification for testing of quality control in computed radiography (CR)' and 'specification for testing of quality control in X-ray mammography'. With the X-ray diagnostic equipment, there are acceptant tests, status tests and routing tests in large hospitals. It is poor for routing test in middle and smaller hospitals. CT is used widely in diagnostic radiology, however most workers in CT

  11. Software to implement the IAEA-TECDOC 1517: quality control in mammography

    International Nuclear Information System (INIS)

    Mora Rodriguez, Patricia

    2011-01-01

    Mammography quality control is presented; also, guidelines for establishing a quality control program through tests to be performed, equipment, frequencies and tolerances. The work is intended for radiologists, medical physicists and technologists. Also examples of data collection sheets, minimum equipment list and overview of a quality control program are included. Two projects (RLA/9/057 and RLA/9/067) raised the goal of developing a software that allows a simple and effective way to automate the evidence contained in the TECDOC. The V1 is presented in the IRPA 12 (2008), which was tested in some countries to detect problems in their use and include possible improvements. However, the final revised version for distribution in member countries was get in 2010. The way of work on the project is described and who has worked. Also, a complete program, its importance and the projection of the Universidad de Costa Rica to work with the same. (author) [es

  12. Procuring, maintaining and using equipment: the key issues in controlling exposure to patients

    International Nuclear Information System (INIS)

    Hendra, I.R.F.

    1989-01-01

    Not only are acceptance criteria directly related to the design of medical x-ray equipment and quality assurance exercised during its manufacture, but also its performance, safety and reliability must feature in requirements for procuring new equipment. In the UK this issue is dealt with under the Department of Health and Social Security Manufacturer Registration Scheme for Medical Equipment in its application to radiological equipment. In the UK quality of maintenance services has been considered by one of our Working Parties commissioned by the South-East Thames Regional Health Authority who are the ''Centre of Responsibility'' for diagnostic imaging equipment in the National Health Service. The report prepared from the first phase of activity of this working group describes features of a procurement specification for maintenance services and prescribes complementary duties of contractors and customers. Radiograph reject analysis has indicated human error outweighs unsatisfactory equipment performance as the reason for rejecting poor radiographs. The use in X-ray departments of the kind of manufacturing quality system used by most reputable equipment manufacturers has the potential for a dramatic reduction in exposure. (author)

  13. Design of special purpose equipment - remote control dozer

    International Nuclear Information System (INIS)

    Aprameyan, K.

    1990-01-01

    Operation environment in handling hot slag, radio active material, clearing/dismantling buildings and loose rocky zones pose hazards with the operation of heavy duty vehicles. Under such hazardous environment conditions, elimination of operator becomes the prime criteria. Remote control of heavy vehicles is resorted to operate the equipment in various working conditions. Radio control systems coupled with penumatic/hydraulic actuators and proportional control logics aim total control of the equipment from a distance using hand pendants. Bharat Earth Moovers Limited has successfully developed remote control system for dozers of 200hp and 300hp. (author). 3 figs

  14. Metrology and quality control handbook

    International Nuclear Information System (INIS)

    Hofmann, D.

    1983-01-01

    This book tries to present the fundamentals of metrology and quality control in brief surveys. Compromises had to be made in order to reduce the material available to a sensible volume for the sake of clarity. This becomes evident by the following two restrictions which had to made: First, in dealing with the theoretical principles of metrology and quality control, mere reference had to be made in many cases to the great variety of special literature without discussing it to explain further details. Second, in dealing with the application of metrology and quality control techniques in practice, only the basic qantities of the International System of Units (SI) could be taken into account as a rule. Some readers will note that many special measuring methods and equipment known to them are not included in this book. I do hope, however, that this short-coming will show to have a positive effect, too. This book will show the reader how to find the basic quantities and units from the derived quantities and units, and the steps that are necessary to solve any kind of measuring task. (orig./RW) [de

  15. Procuring, maintaining and using equipment: the key issues in controlling exposure to patients

    International Nuclear Information System (INIS)

    Hendra, I.R.F.

    1989-01-01

    Radiological equipment is not purpose-built for each individual application. Thus, not only are acceptance criteria directly related to the design of equipment and the quality assurance exercised during its manufacture, but also the performance, safety and reliability of equipment must feature in the requirements for procuring new equipment. In the UK this issue is dealt with under the Department of Health and Social Security Manufacturer Registration Scheme for Medical Equipment in its application to radiological equipment. Similarly the continuing reliability of equipment in service is directly related to the quality of maintenance services. This is determined largely by the manner in which such services are procured. In the UK this issue has been considered by one of four Working Parties commissioned by the South-East Thames Regional Health Authority who are the ''Centre of Responsibility'' for diagnostic imaging equipment. The report prepared from the first phase of activity of this working group describes features of a procurement specification for maintenance services and prescribes the complementary duties of contractors and customers. The use in X-ray departments of the kind of manufacturing quality system that is used by most reputable equipment manufacturers has the potential for a dramatic reduction in exposure to patients. (author)

  16. Dynamic monitoring equipment for earthworks and sub grades

    International Nuclear Information System (INIS)

    Alvarez de Sotomayor, R.

    2013-01-01

    This paper take into account some dynamic auscultation equipment s that currently are available in Spain for compaction quality control on earthworks and sub grades. Closed to the equipment description, a deformation modulus calculus approximation has been developed for each of them. A standards checking has been made from national and European point of view. some important research works that have been developed in our country about dynamic monitoring equipment s for quality control in earthworks has been mentioned. In addition to this, some variables are analyzed which have an influence on deformation modulus calculi and a possibility for comparing the equipment modulus calculated with a reference laboratory test has been offered. (Author) 18 refs.

  17. Radiation therapy quality control in MRCCC radiotherapy units

    International Nuclear Information System (INIS)

    Fielda Djuita; Rina Taurisia; Andreas Nainggolan

    2011-01-01

    Increasing cancer patients in Indonesia is not supported with the number of equipment that is able to treat cancer patients, especially in the radiation therapy field. Therefore, several private hospitals have joined to provide radiation therapy services and one of them is MRCCC. As a new hospital providing services in radiotherapy field, the writer tries to present our quality control program that we have done in our hospital. Purpose: As quality control to radiation therapy clinical practice. Methods: Descriptive essay of what we do in our institution. Conclusion: Average output photon and electron lower more than tolerance dose. (author)

  18. Quality control of mammography

    International Nuclear Information System (INIS)

    Hering, K.G.

    1986-01-01

    Random checks of mammograms allow to clearly assess quality controls concerning correct application and operation of the radiographic system indicated by rich contrast in breast tissue images, complete imaging of the mammary parenchyma, freedom from blurs due to motion, efficient breast compression, correct film labelling and perfect maintenance of the film screen system. In addition to these subjective assessments, the following points should be considered when using objective measurement procedures and phantoms: Testing the correct function of X-ray and radiographic equipment by means of test specimens to measure KV standard (KV=Association of German Panel Doctors), mAS and automatic exposure timer; comparing dose and density to initial values and checking film processing by using a sensitometer. Quality assurance handling varies from one KV to the next. That is why the users need to obtain the guidelines of the respective KV relative to radiological quality assurance and to proceed according to these. (orig.) [de

  19. Specialized software for optimization of the quality control of the mammography units

    International Nuclear Information System (INIS)

    Stoeva, M.; Vassileva, J.

    2004-01-01

    Quality control is essential to ensure the equipment used is reliable and consistent in order to maintain radiation does as low as reasonably achievable whilst optimizing image quality and performance in mammography. The effectiveness of mammographic screening is highly dependent on the consistent production of high quality diagnostic images. Mammography is highly dependent on the equipment status, which requires an effective Quality Control (QC) program to provide tools for continuous assessment of the equipment performance and also data storage and analysis of the protocols' data. The objective of this paper is to present the specialized software for Quality Control of the Mammography Units, as tool providing additional functionality for optimizations of the Mammography QC data storage and management. The PC program was developed according to the requirements stated in the European protocol for Quality Control of the Mammography Screening and the data collected as a result of its application in several Bulgarian hospitals. The Structured Analysis method was used in order to perform a case, which resulted in the development of the specialized software with a database module, providing the following functionality: Data Storage, Preliminary Data Processing and Post-Processing, Manual Data Entry, Data Import from XLS format, Data Export to XLS format, Printing, Data Filters, Automated Calculation, Automated Graphical Representation, Archiving The development of specialized QC software with a database for mammography units facilitates the process of QC data storage and handling and minimizes the errors. The electronic format for data storage is especially useful in case of long-term storage and periodical data analysis/access. The integrated data processing functionality and the automated import/export features based on standard platform increase the compatibility of the data. (authors)

  20. Quality assurance and quality control in mammography: A review

    International Nuclear Information System (INIS)

    BenComo, Jose A.

    2000-01-01

    A mammogram is among the most technically demanding radiographic procedures. The early detection of breast cancer relies on the radiologist's ability to perceive subtle changes in the image that are only perceptible with high-quality imaging. Early detection of breast cancer is only as reliable as the mammogram with which a diagnosis is made, and a mammogram is only as accurate as the system that produces it. A quality assurance (QA) program maximizes the likelihood that the mammographic images will provide adequate diagnostic information for the least possible radiation exposure and cost to the patient. The QA program monitors each phase of operation of the imaging facility beginning with the request for an examination and ending with the interpretation of the referring physician and ensures that the imaging equipment used for the examination will yield the information desired. Because image quality is the most important technical aspect of mammography, this review summarizes the most important QA and quality control issues

  1. As the thermoluminescent dosimetry can help in the quality control in radiotherapy

    International Nuclear Information System (INIS)

    Araujo, Anna Maria Campos de; Marin, Alfredo Viamonte; Viegas, Claudio C.B.; Souza, Roberto Salomon de; Alves, Victor Gabriel Leandro

    2011-01-01

    According to the international (International Atomic Energy Agency) and national (Agencia Nacional de Vigilancia Sanitaria- ANVISA) rules, the irradiators of any radiotherapy department should be periodical/y checked through a quality control external audit. In Brazil, where we have about 300 radiotherapy equipment, is very difficult to perform these audits on site with a acceptable frequency. For this reason, the Quality Service on Ionizing Radiations from the National Cancer Institute-INCA/Rio de Janeiro, developed and implemented postal systems to evaluate the main parameters of the radiotherapeutic equipment (Co-60, linear accelerators and high dose rate brachytherapy). All the postal systems developed are based on thermoluminescent dosimeters. The aim of this paper is to share the INCA experience in the use of TLD for dose evaluation and quality control measurements. Following the same philosophy, INCA developed also a postal system to evaluate the doses in mammography, since Brazil has 4000 equipment and performs about 8 millions of mammograms per year. A new experience is studying the OSL dosimeters to be used also for dose evaluation, including for in vivo dosimetry. (author)

  2. Maintenance of medical nuclear equipment. A proposal for quality control in radiotherapy

    International Nuclear Information System (INIS)

    Becker, Paulo H.B.

    1996-01-01

    A project of quality control in radiotherapy that is been implemented by Instituto de Radioprotecao e Dosimetria from Brazilian National Energy Commission (CNEN) in cooperation with International Atomic Energy Agency is described. The establishment of a laboratory for the maintenance of medical dosemeters is proposed

  3. Quality-control activities of the Hanford Environmental Surveillance Program

    International Nuclear Information System (INIS)

    Price, K.R.; Jaquish, R.E.

    1982-01-01

    A comprehensive approach to quality control (QC) has been developed by the Pacific Northwest Laboratory for the Hanford Environmental Surveillance Program. The framework of quality control for the surveillance program has been documented in a QC implementation guide wherein QC requirements are specified and specific responsibilities and authorities are described. Subjects in the guide include the collection, analysis, and reporting of samples as well as equipment calibration and maintenance, training, audits, and record keeping. A QC file and library have been established to store pertinent documentation, records, and references for ready access

  4. The application of probability methods with a view to improving the quality of equipment

    International Nuclear Information System (INIS)

    Carnino, A.; Gachot, B.; Greppo, J.-F.; Guitton, J.

    1976-01-01

    After stating that reliability and availability could be considered as parameters allowing the quality of equipment to be estimated, the chief aspects of the use of probability methods in the field of quality is described. These methods are mainly applied at the design, operation and maintenance level of the equipment, as well as at the compilation stage of the corresponding data [fr

  5. Express quality control of chicken eggs by machine vision

    Science.gov (United States)

    Gorbunova, Elena V.; Chertov, Aleksandr N.; Peretyagin, Vladimir S.; Korotaev, Valery V.; Arbuzova, Evgeniia A.

    2017-06-01

    The urgency of the task of analyzing the foodstuffs quality is determined by the strategy for the formation of a healthy lifestyle and the rational nutrition of the world population. This applies to products, such as chicken eggs. In particular, it is necessary to control the chicken eggs quality at the farm production prior to incubation in order to eliminate the possible hereditary diseases, as well as high embryonic mortality and a sharp decrease in the quality of the bred young. Up to this day, in the market there are no objective instruments of contactless express quality control as analytical equipment that allow the high-precision quality examination of the chicken eggs, which is determined by the color parameters of the eggshell (color uniformity) and yolk of eggs, and by the presence in the eggshell of various defects (cracks, growths, wrinkles, dirty). All mentioned features are usually evaluated only visually (subjectively) with the help of normalized color standards and ovoscopes. Therefore, this work is devoted to the investigation of the application opportunities of contactless express control method with the help of technical vision to implement the chicken eggs' quality analysis. As a result of the studies, a prototype with the appropriate software was proposed. Experimental studies of this equipment on a representative sample of eggs from chickens of different breeds have been carried out (the total number of analyzed samples exceeds 300 pieces). The correctness of the color analysis was verified by spectrophotometric studies of the surface of the eggshell.

  6. Automated Quality Assurance of Medical Digital X-Ray Equipment

    International Nuclear Information System (INIS)

    Zelikman, Mikhail; Kruchinin, Sergey

    2013-06-01

    Quality assurance of the x-ray equipment includes a set of various tests among which are installation and periodic exams performed by qualified engineers as well as daily routine tests carried out by the medical staff of the Radiology Department. As a rule, the decision concerning the applicability of the x-ray equipment for using in clinical studies is made on the basis of the routine tests results. The presented method is based on the detector's output signals, Signal-to-Noise Ratio and Modulation Transfer Function evaluation in automated way using the simple test-object's digital image registered with given geometry and x-ray exposure parameters settings. Rectangular 20 mm thick aluminum plate with fixed 1 mm thick well-finished steel edge (for general x-ray radiography/fluoroscopy systems) or 2 mm thick aluminum plate with fixed 1 mm thick aluminum well-finished edge (for digital x-ray mammography systems) can be used as a test equipment. Relevant to the decision concerning the x-ray device operation status are the parameters: deviations from the reference levels of the tube voltage and mAs as well as internal detector's noise variance and detector's gain deviations. Everyday testing procedure includes the following steps. On the first step the roentgenographer places the test-object at the center of the detector's surface, makes an exposure with specified parameters setting and geometry and after this, test results are displayed on the work station monitor or console screen in automatic way. In order to provide an automated regime of the presenting algorithm, the software must be integrated with the program module intended for the x-ray device control. The use of the presented method in clinical practice provides the reliable daily monitoring of the x-ray equipment operation status prior to its utilizing for patient diagnostic process. As a rule, it will take not more than 3-5 minutes for the roentgenographer to complete the routine

  7. Radiotherapy procedures quality control program: Guidelines established by the Spanish Society of Radiotherapy and Oncology

    International Nuclear Information System (INIS)

    Palacios, A.; Pardo, J.; Valls, A.; Petschen, I.; Castell, A.; Villar, A.; Pedro Olive, B.A.; Munoz, V.; Fernandez, J.; Rodriguez, R.; Oton, C.

    2001-01-01

    The main purpose of the Royal Decree 1566/1998 of July 17 th , is to establish the quality criteria in radiation therapy in order to assure the optimisation of both radiation oncology treatments and radiation protection of the patients. According to this decree, the implementation of a quality control program in the radiation oncology departments is imperative. This program must be in writing and always available for supervision of health authorities. When necessary, modifications to improve non-optimal procedures or equipment will be made. The Spanish Society of Radiotherapy and Oncology, in order to co-operate and facilitate to all its members, set up a task force focussing on elaborating a set of guidelines that every single Radiation Oncology Department could use to develop its own quality control program. No agreements regarding equipment quality control were made by the Commission, in spite they are a part of the quality control program in radiotherapy, because it is considered that they correspond to members of other scientific societies. (author)

  8. INCREASING OF ECOLOGICAL EFFICIENCY OF WORN EQUIPMENT BY PARTIAL UPDATES. ANALYTICAL AND CONTROL ASPECT

    Directory of Open Access Journals (Sweden)

    S. Voinova

    2017-12-01

    Full Text Available The current state of worn industrial equipment and the resulting low performance indicators of its functioning, in particular, low environmental friendliness, are considered. It is shown that the normalization of the complex situation that has developed in production is an acute problem, the solution of which should begin with the implementation of a program for the partial renewal of worn equipment. It is pointed out that there is a high potential for improving the technological, including ecological, efficiency of functioning of the upgraded equipment. It is pointed out that the partial renewal is highly efficient, because of the small specific investments in it. The significant influence of the quality of control of the setting and implementation of the renewal program on its effectiveness was noted. It is shown that the process of renewal of worn-out equipment, ultimately, has an environmental focus, increases the environmental friendliness of the updated technical facility.

  9. Pilot program of quality control in mammography and conventional equipment in the Antioquia Department; Programa piloto de control de calidad en mamografia y equipos convencionales en el Departamento de Antioquia

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, P. [Direccion Seccional de Salud de Antioquia (Colombia); Puerta, J.A.; Morales, J. [Universidad Nacional de Colombia, Sede Medellin (Colombia); Beltran, C.C. [Asociacion Colombiana de Proteccion Radiologica (Colombia)]. e-mail: japuerta@unal.edu.co

    2006-07-01

    The Sectional Health Division of Antioquia and the National University of Colombia- Medellin Headquarters formalized an agreement for the realization of the quality control of thirty mammographs and twenty-five conventional X-ray equipment located in the one metropolitan area of Medellin, and ten municipalities of the nine regions in that the antioquen county is divided. The National University of Colombia- Headquarters Medellin possesses a program for the formation in quality control and radiological protection at master level in physics for that which endowed a radiodiagnostic laboratory for these purposes. In the Antioquia department only exists an institution, the San Vicente of Paul University Hospital that possesses a quality control program in radiodiagnostic; this hospital given its great volume of studies in radiodiagnostic has a medical physicist and of that instrumental necessary to maintain the program. The quality control programs have not been implemented in the rest of health institutions, public or private, big or small, until the moment. The project then allowed to carry out an initial evaluation of the pertinent parameters of the quality control of the facilities like its are those that refer to the state of the x-ray generator, the disposition of the installation, the dark room, the film processor and negatoscopies room; these its were carried out with base in the protocol produced in the ARCAL XLIX project in which participated six Latin American countries. The dose average in mammography, following the proposed course in the ARCAL LXXV, where its participate eleven Latin American countries was also evaluated. This study pilot serves like reference of the current state of the regional radiodiagnostic services, with base in this sampling that is representative. The obtained data gave the necessary information so that the Sectional Division of Health of Antioquia can generate tending actions to the implementation of quality guarantee programs and

  10. The pharmaceutical vial capping process: Container closure systems, capping equipment, regulatory framework, and seal quality tests.

    Science.gov (United States)

    Mathaes, Roman; Mahler, Hanns-Christian; Buettiker, Jean-Pierre; Roehl, Holger; Lam, Philippe; Brown, Helen; Luemkemann, Joerg; Adler, Michael; Huwyler, Joerg; Streubel, Alexander; Mohl, Silke

    2016-02-01

    Parenteral drug products are protected by appropriate primary packaging to protect against environmental factors, including potential microbial contamination during shelf life duration. The most commonly used CCS configuration for parenteral drug products is the glass vial, sealed with a rubber stopper and an aluminum crimp cap. In combination with an adequately designed and controlled aseptic fill/finish processes, a well-designed and characterized capping process is indispensable to ensure product quality and integrity and to minimize rejections during the manufacturing process. In this review, the health authority requirements and expectations related to container closure system quality and container closure integrity are summarized. The pharmaceutical vial, the rubber stopper, and the crimp cap are described. Different capping techniques are critically compared: The most common capping equipment with a rotating capping plate produces the lowest amount of particle. The strength and challenges of methods to control the capping process are discussed. The residual seal force method can characterize the capping process independent of the used capping equipment or CCS. We analyze the root causes of several cosmetic defects associated with the vial capping process. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Quality control of CANDU6 fuel element in fabrication process

    International Nuclear Information System (INIS)

    Li Yinxie; Zhang Jie

    2012-01-01

    To enhance the fine control over all aspects of the production process, improve product quality, fuel element fabrication process for CANDU6 quality process control activities carried out by professional technical and management technology combined mode, the quality of the fuel elements formed around CANDU6 weak links - - end plug , and brazing processes and procedures associated with this aspect of strict control, in improving staff quality consciousness, strengthening equipment maintenance, improved tooling, fixtures, optimization process test, strengthen supervision, fine inspection operations, timely delivery carry out aspects of the quality of information and concerns the production environment, etc., to find the problem from the improvement of product quality and factors affecting the source, and resolved to form the active control, comprehensive and systematic analysis of the problem of the quality management concepts, effectively reducing the end plug weld microstructure after the failure times and number of defects zirconium alloys brazed, improved product quality, and created economic benefits expressly provided, while staff quality consciousness and attention to detail, collaboration department, communication has been greatly improved and achieved very good management effectiveness. (authors)

  12. Configuration control during maintenance of safety related equipment

    International Nuclear Information System (INIS)

    Irish, C.S.

    2001-01-01

    Possibly the most important aspect of performing maintenance of safety related equipment is maintaining the component's original design basis. Assuring that the repaired item will perform the same safety function within the original performance and equipment qualification parameters is commonly referred to as configuration control. Maintaining configuration control of a technologically current well documented item is easy. Unfortunately, this does not describe most safety related items requiring maintenance within the global nuclear industry. Items such as motors, transformers, metal clad switchgear (low and medium voltage circuit breakers), refrigeration compressors, and electronic components (i.e. circuit boards, power supplies, regulators, etc.) which routinely require repair have been in service for twenty plus years. As a result, finding replacement parts and or material to repair the items to the original condition is becoming more and more difficult. An added difficulty is the lack of original technical documentation available on the item which is being repaired. The lack of technical documentation makes it difficult to identify replacement material and parts when the original part or material is not available. The lack of documentation also makes it difficult to test the repaired item to make sure that the original configuration has been maintained after the repair. The presentation will discuss the details of repairing various items including motors, metal clad switchgear, refrigeration compressors and power supplies and the controls which are necessary to maintain the configuration of the original item. The discussion will include the Quality Assurance and engineering necessary to identify and evaluate replacement material and parts necessary to perform repairs on safety related equipment when the original material or part is not available. Examples of repairs which required different parts or materials than the original to be used in the repair will be

  13. Configuration control during maintenance of safety related equipment

    International Nuclear Information System (INIS)

    Irish, C.S.

    2003-01-01

    Possibly the most important aspect of performing maintenance of safety related equipment is maintaining the component's original design basis. Assuring that the repaired item will perform the same safety function within the original performance and equipment qualification parameters is commonly referred to as configuration control. Maintaining configuration control of a technologically current well documented item is easy. Unfortunately, this does not describe most safety related items requiring maintenance within the global nuclear industry. Items such as motors, transformers, metal clad switchgear (low and medium voltage circuit breakers), refrigeration compressors, and electronic components (i.e. circuit boards, power supplies, regulators, etc.) which routinely require repair have been in service for twenty plus years. As a result, finding replacement parts and or material to repair the items to the original condition is becoming more and more difficult. An added difficulty is the lack of original technical documentation available on the item which is being repaired. The lack of technical documentation makes it difficult to identify replacement material and parts when the original part or material is not available. The lack of documentation also makes it difficult to test the repaired item to make sure that the original configuration has been maintained after the repair. The presentation will discuss the details of repairing various items including motors, metal clad switchgear, refrigeration compressors and power supplies and the controls which are necessary to maintain the configuration of the original item. The discussion will include the Quality Assurance and engineering necessary to identify and evaluate replacement material and parts necessary to perform repairs on safety related equipment when the original material or part is not available. Examples of repairs which required different parts or materials than the original to be used in the repair will be

  14. Improving the quality control program for patient dose calibrator according to IEC 60580

    International Nuclear Information System (INIS)

    Costa, Nathalia Almeida; Potiens, Maria da Penha Albuquerque

    2013-01-01

    The objective of this work was to improve the program quality control of this equipment based on the International Standard IEC 60580 - Medical electrical equipment - Dose area product meters . The initial program was established following the recommendations of IEC 61674 quoting dosimeters with ionization chambers and / or semiconductor detectors used in diagnostic X-ray image, however, the IEC 60580 is referred specifically to gauges and KAP (kerma-area product) presents additional tests. Tests included: intrinsic relative error, repeatability, scanning resolution, settling time, restarting, float values, response time and spatial uniformity of response. As a rule, all measurements are within the range characteristic of equipment performance. Thus, the PDC (Patient Dose Calibrator) again shows a device with excellent functionality and reliability in characterization tests carried out to quality control as( for the test in clinical PKA meters

  15. The main tests for quality control in X-ray equipment of radiodiagnosis

    International Nuclear Information System (INIS)

    Ferreira, R.S.

    1988-01-01

    All aspects of the relation between patient, examination and diagnosis for controling the quality in radiodiagnosis are showed. The bundle collimation for decreasing the scattered radiation in patient and the systems for measuring the exposure time are described. The yield valuation and the tension for X-rays tube are also cited. (C.G.C.) [pt

  16. Implementation of quality control program in radiodiagnostic services

    International Nuclear Information System (INIS)

    Herrera S, A.; Roas Z, N.

    1995-01-01

    This monograph is the first version of the implementation of the quality control programme in radiology diagnostic services. Here all information related to diagnostic quality to better radiation protection to patients and personnel was collected. The programme was implemented on the X-ray equipment at three hospitals (named hospital A, hospital B and hospital C) and included the evaluation of technical parameters such as kilovolts, exposition time, filtration, fields. In addition, dark room, chassis and image intensifiers were also evaluated. The procedures to carry out the quality control and the manner in which the observations, conclusions and recommendations should be formulated are based on documents issued by the International Commission on Radiological Protection (I.C.R.P.), International Atomic Energy Agency (I.A.E.A.) and World Health Organization (W.H.O.)

  17. Optimization of a radiodiagnostic service by means of quality control

    International Nuclear Information System (INIS)

    Carrizales, L.; Gamez, L.; Reggio, F.; Gamboa, M.; Quintero, A.; Almeida, J.

    2001-01-01

    Most of the radio diagnosis institutions (public and private) in Venezuela have a lack quality control applied to radiological equipment, as well as capable staff to implement it. It is intended to implant training programs and corrective policies to optimize their services [es

  18. RETRIEVAL EQUIPMENT DESCRIPTIONS

    International Nuclear Information System (INIS)

    J. Steinhoff

    1997-01-01

    The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) retrieval from the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. There are no quality assurance requirements or QA controls in this document. Retrieval under normal conditions is accomplished with the same fleet of equipment as is used for emplacement. Descriptions of equipment used for retrieval under normal conditions is found in Emplacement Equipment Descriptions, DI: BCAF00000-01717-5705-00002 (a document in progress). Equipment used for retrieval under abnormal conditions is addressed in this document and consists of the following: (1) Inclined Plane Hauler; (2) Bottom Lift Transporter; (3) Load Haul Dump (LHD) Loader; (4) Heavy Duty Forklift for Emplacement Drifts; (5) Covered Shuttle Car; (6) Multipurpose Vehicle; and (7) Scaler

  19. Sci-Fri AM: Quality, Safety, and Professional Issues 01: CPQR Technical Quality Control Suite Development including Quality Control Workload Results

    Energy Technology Data Exchange (ETDEWEB)

    Malkoske, Kyle; Nielsen, Michelle; Brown, Erika; Diamond, Kevin; Frenière, Normand; Grant, John; Pomerleau-Dalcourt, Natalie; Schella, Jason; Schreiner, L. John; Tantot, Laurent; Barajas, Eduardo Villareal; Bissonnette, Jean-Pierre [Royal Victoria Hospital, Trillium Health Partners, CPQR, Juravinski Cancer Centre, CIUSSS MCQ - CHAUR, Cape Breton Health Care Complex, Centre d’oncologie Dr. Léon-Richard / Dr. Léon Richard Oncology Centre, QEII Health Sciences Centre, Cancer Centre of Southeastern Ontario, Hôpital Maisonneuve-Rosemont, Tom Baker Cancer Centre, Princess Margaret Cancer Centre (Canada)

    2016-08-15

    A close partnership between the Canadian Partnership for Quality Radiotherapy (CPQR) and the Canadian Organization of Medical Physicist’s (COMP) Quality Assurance and Radiation Safety Advisory Committee (QARSAC) has resulted in the development of a suite of Technical Quality Control (TQC) Guidelines for radiation treatment equipment, that outline specific performance objectives and criteria that equipment should meet in order to assure an acceptable level of radiation treatment quality. The framework includes consolidation of existing guidelines and/or literature by expert reviewers, structured stages of public review, external field-testing and ratification by COMP. The adopted framework for the development and maintenance of the TQCs ensures the guidelines incorporate input from the medical physics community during development, measures the workload required to perform the QC tests outlined in each TQC, and remain relevant (i.e. “living documents”) through subsequent planned reviews and updates. This presentation will show the Multi-Leaf Linear Accelerator document as an example of how feedback and cross-national work to achieve a robust guidance document. During field-testing, each technology was tested at multiple centres in a variety of clinic environments. As part of the defined feedback, workload data was captured. This lead to average time associated with testing as defined in each TQC document. As a result, for a medium-sized centre comprising 6 linear accelerators and a comprehensive brachytherapy program, we evaluate the physics workload to 1.5 full-time equivalent physicist per year to complete all QC tests listed in this suite.

  20. Sci-Fri AM: Quality, Safety, and Professional Issues 01: CPQR Technical Quality Control Suite Development including Quality Control Workload Results

    International Nuclear Information System (INIS)

    Malkoske, Kyle; Nielsen, Michelle; Brown, Erika; Diamond, Kevin; Frenière, Normand; Grant, John; Pomerleau-Dalcourt, Natalie; Schella, Jason; Schreiner, L. John; Tantot, Laurent; Barajas, Eduardo Villareal; Bissonnette, Jean-Pierre

    2016-01-01

    A close partnership between the Canadian Partnership for Quality Radiotherapy (CPQR) and the Canadian Organization of Medical Physicist’s (COMP) Quality Assurance and Radiation Safety Advisory Committee (QARSAC) has resulted in the development of a suite of Technical Quality Control (TQC) Guidelines for radiation treatment equipment, that outline specific performance objectives and criteria that equipment should meet in order to assure an acceptable level of radiation treatment quality. The framework includes consolidation of existing guidelines and/or literature by expert reviewers, structured stages of public review, external field-testing and ratification by COMP. The adopted framework for the development and maintenance of the TQCs ensures the guidelines incorporate input from the medical physics community during development, measures the workload required to perform the QC tests outlined in each TQC, and remain relevant (i.e. “living documents”) through subsequent planned reviews and updates. This presentation will show the Multi-Leaf Linear Accelerator document as an example of how feedback and cross-national work to achieve a robust guidance document. During field-testing, each technology was tested at multiple centres in a variety of clinic environments. As part of the defined feedback, workload data was captured. This lead to average time associated with testing as defined in each TQC document. As a result, for a medium-sized centre comprising 6 linear accelerators and a comprehensive brachytherapy program, we evaluate the physics workload to 1.5 full-time equivalent physicist per year to complete all QC tests listed in this suite.

  1. Cooling water conditioning and quality control for tokamaks

    International Nuclear Information System (INIS)

    Gootgeld, A.M.

    1995-10-01

    Designers and operators of Tokamaks and all associated water cooled, peripheral equipment, are faced with the task of providing and maintaining closed-loop, low conductivity, low impurity, cooling water systems. Most of these systems must provide large volumes of high quality cooling water at reasonable cost and comply with local and state government orders and EPA mandated national pretreatment standards and regulations. This paper discusses the DIII-D water quality requirements, the means used to obtain the necessary quality and the instrumentation used for control and monitoring. Costs to mechanically and chemically condition and maintain water quality are discussed as well as the various aspects of complying with government standards and regulations

  2. Test of remote control cutting equipment by Nd:YAG laser

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Akio [Fuji Electric Corp. Research and Development Ltd., Yokosuka, Kanagawa (Japan); Hosoda, Hiroshi

    1997-11-01

    Technology of remote controlled cutting and reduction of generative secondary products have been required to the cutting system for decommissioning nuclear equipments. At a point of view that laser cutting technology by use of a Nd:YAG laser is effective, we have developed the laser cutting machine and carried out cutting tests for several stainless steel plates. This report is described the result of experiment by test equipment, about element technology of remote controlled cutting nuclear equipments. (author)

  3. Test of remote control cutting equipment by Nd:YAG laser

    International Nuclear Information System (INIS)

    Shimizu, Akio; Hosoda, Hiroshi.

    1997-01-01

    Technology of remote controlled cutting and reduction of generative secondary products have been required to the cutting system for decommissioning nuclear equipments. At a point of view that laser cutting technology by use of a Nd:YAG laser is effective, we have developed the laser cutting machine and carried out cutting tests for several stainless steel plates. This report is described the result of experiment by test equipment, about element technology of remote controlled cutting nuclear equipments. (author)

  4. Quality control in digital mammography: the noise components

    Energy Technology Data Exchange (ETDEWEB)

    Leyton, Fernando [Universidade de Tarapaca, Arica (Chile). Centro de Estudios en Ciencias Radiologicas; Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Nogueira, Maria do Socorro, E-mail: mnogue@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Duran, Maria Paz [Clinica Alemana, Santiago (Chile). Dept. de Radiologia; Dantas, Marcelino, E-mail: marcelino@inb.gov.b [Industrias Nucleares do Brasil (INB), Caldas, MG (Brazil). Unidade de Tratamento de Minerios; Ubeda, Carlos, E-mail: cubeda@uta.c [Universidade de Tarapaca, Arica (Chile). Fac. de Ciencias de la Salud

    2011-07-01

    To measure the linearity of the detector and determine the noise components (quantum, electronic and structural noise) that contributed to losing image quality and to determine the signal noise ratio (SNR) and contrast noise ratio (CNR). This paper describes the results of the implementation of a protocol for quality control in digital mammography performed in two direct digital mammography equipment (Hologic, Selenia) in Santiago of Chile. Shows the results of linearity and noise analysis of the images which establishes the main cause of noise in the image of the mammogram to ensure the quality and optimize procedures. The study evaluated two digital mammography's Selenia, Hologic (DR) from Santiago, Chile. We conducted the assessment of linearity of the detector, the signal noise ratio, contrast noise ratio and was determined the contribution of different noise components (quantum, electronics and structural noise). Used different thicknesses used in clinical practice according to the protocol for quality control in digital mammography of Spanish society of medical physics and NHSBSP Equipment Report 0604 Version 3. The Selenia mammography software was used for the analysis of images and Unfors Xi detector for measuring doses. The mammography detector has a linear performance, the CNR and SNR did not comply with the Protocol for the thicknesses of 60 and 70 mm. The main contribution of the noise corresponds to the quantum noise, therefore it is necessary to adjust and optimize the mammography system. (author)

  5. Quality control in digital mammography: the noise components

    International Nuclear Information System (INIS)

    Leyton, Fernando; Nogueira, Maria do Socorro; Duran, Maria Paz; Dantas, Marcelino; Ubeda, Carlos

    2011-01-01

    To measure the linearity of the detector and determine the noise components (quantum, electronic and structural noise) that contributed to losing image quality and to determine the signal noise ratio (SNR) and contrast noise ratio (CNR). This paper describes the results of the implementation of a protocol for quality control in digital mammography performed in two direct digital mammography equipment (Hologic, Selenia) in Santiago of Chile. Shows the results of linearity and noise analysis of the images which establishes the main cause of noise in the image of the mammogram to ensure the quality and optimize procedures. The study evaluated two digital mammography's Selenia, Hologic (DR) from Santiago, Chile. We conducted the assessment of linearity of the detector, the signal noise ratio, contrast noise ratio and was determined the contribution of different noise components (quantum, electronics and structural noise). Used different thicknesses used in clinical practice according to the protocol for quality control in digital mammography of Spanish society of medical physics and NHSBSP Equipment Report 0604 Version 3. The Selenia mammography software was used for the analysis of images and Unfors Xi detector for measuring doses. The mammography detector has a linear performance, the CNR and SNR did not comply with the Protocol for the thicknesses of 60 and 70 mm. The main contribution of the noise corresponds to the quantum noise, therefore it is necessary to adjust and optimize the mammography system. (author)

  6. IRRIGATION STATION EQUIPMENT FOR PREVENTING THE USE OF LOW WATER QUALITY

    Directory of Open Access Journals (Sweden)

    Constantin Nicolescu

    2010-01-01

    Full Text Available In Romania the economically efficient irrigated area is estimated at 3.5 million hectares. On national scale there is nointegrated approach for monitoring the quantity and quality of the irrigation water, using adequate equipment at thepumping station. On international scale, in many countries the pumping stations are provided with equipment formonitoring, on real time, the quality or the pumped water and for warning about critical situations (emergencies.This paper describes a technical solution consisting of equipment which monitors the following parameters of waterpumped in irrigation systems: turbidity, pH, CE at 25 o C, Na+, Cl-. The lapse of time for monitoring is of 10 to 60 min.The main components are the following: the sampling pump (submersible the monitoring board, the repression pipe ofthe analyzed water. Warnings are made about values exceeding the programmed level for each monitored parameter,about the fact that the pump and agitator do not work or about any other source of damage.The technical solution and equipment were tested at a pumping station which uses water from Danube, in most casesmixed with water originating from drainage. Results showed a reduction of the total content of soluble salts from soiland of their negative impact upon the crops, a reduction of the degree of river alluvial deposits within the irrigationsystem and reduction of the energetic consumption required for pumping.

  7. Evaluation of quality control in the college of medical radiological sciences, conventional x-ray department

    International Nuclear Information System (INIS)

    Babiker, Esameldeen Mohamed Tom

    2002-02-01

    Quality control in diagnostic radiography aims to ensure continuous production of diagnostic images with optimum quality, using minimum necessary dose to the patients and staff. Therefore an ineffective quality control program can lead to poor quality images that can impair diagnosis, increase operating costs and contribute to unnecessary radiation exposure to both patients and staff. Apply basic quality control program is responsibility of each x-ray facility, and to achieve maximum benefits, all levels of management and technical staff must support and participate in operating the programme. The main parameters to be monitored during the quality control programme include: dose consistency, k Vp accuracy, k Vp variations, exposure timer accuracy, besides checking image receptors, recording system and processing conditions. The aims of this project is to evaluate the quality control in the x-ray department of the college of medical radiologic sciences. The evaluation was an experimental study done by checking the operational status of the radiographic equipment, beside data collection using questionnaires regarding quality control. In the applied experiments the results show that there is a noted variation in the accuracy of k Vp, exposure timer and also in the dose consistency. The obtained results from image receptors and processing system showed noted variations too. The results of the questionnaire and direct interviewing showed other causes of quality degradation such as absence of test tools, the status of the equipment, absence of regular quality control testing, in addition to absence of an organized team to deal with quality. (Author)

  8. A computerized diagnostic system for nuclear plant control rooms based on statistical quality control

    International Nuclear Information System (INIS)

    Heising, C.D.; Grenzebach, W.S.

    1990-01-01

    In engineering science, statistical quality control techniques have traditionally been applied to control manufacturing processes. An application to commercial nuclear power plant maintenance and control is presented that can greatly improve safety. As a demonstration of such an approach to plant maintenance and control, a specific system is analyzed: the reactor coolant pumps of the St. Lucie Unit 2 nuclear power plant located in Florida. A 30-day history of the four pumps prior to a plant shutdown caused by pump failure and a related fire within the containment was analyzed. Statistical quality control charts of recorded variables were constructed for each pump, which were shown to go out of statistical control many days before the plant trip. The analysis shows that statistical process control methods can be applied as an early warning system capable of identifying significant equipment problems well in advance of traditional control room alarm indicators

  9. standards used for quality control of nuclear fuels

    International Nuclear Information System (INIS)

    Guereli, L; Can, S.

    1997-01-01

    Nuclear fuels and fuel materials are subject to stringent restrictions as to their quality. The standards and regulations that apply vary according to reactor type and country and the standards are stated in the quality assurance documents. The concept of quality assurance has altered the conventional quality control tests and procedures, defining which control tests are to be applied and how. Although most of the tests and measurements allow the determination of tolerances to be decided according to the agreement between the buyer and the seller, exacting procedures apply to which instruments and equipment are used for these tests and measurements, how these instruments are standardized.Detailed explanations of test methods and their documentation is a requirement in all standards. The purpose of this work is to study which standards, tests and measurements apply to the nuclear fuel production. Only the standards that apply to various stages of the nuclear fuel production (powder preparation, pellet production, fuel element and fuel assembly fabrication) are reviewed. Process and documentation control, design and licensing requirements and the frequency of inspections are quality assurance subjects. Some ASTM standards are given as examples

  10. Survey of Current Status of Quality Control of Gamma Cameras in Republic of Korea

    International Nuclear Information System (INIS)

    Choe, Jae Gol; Joh, Cheol Woo

    2008-01-01

    It is widely recognized that good quality control (QC) program is essential for adequate imaging diagnosis using gamma camera. The purpose of this study is to survey the current status of QC of gamma cameras in Republic of Korea for implementing appropriate nationwide quality control guidelines and programs. A collection of data is done for personnel, equipment and appropriateness of each nuclear medicine imaging laboratory's' quality control practice. This survey is done by collection of formatted questionnaire by mails, e mails or interviews. We also reviewed the current recommendations concerning quality assurance by international societies. This survey revealed that practice of quality control is irregular and not satisfactory. The irregularity of the QC practice seems due partly to the lack of trained personnel, equipment, budget, time and hand-on guidelines. The implementation of QC program may cause additional burden to the hospitals, patients and nuclear medicine laboratories. However, the benefit of a good QC program is obvious that the hospitals can provide good quality nuclear medicine imaging studies to the patients. It is important to use least cumbersome QC protocol, to educate the nuclear medicine and hospital administrative personnel concerning QC, and to establish national QC guidelines to help each individual nuclear medicine laboratory

  11. Evaluation of the weekly quality control of a digital mammography machine; Evaluacion del control de calidad semanal de un mamografo digital

    Energy Technology Data Exchange (ETDEWEB)

    Angulo Pain, E.; Ramos Caballero, L. J.; Urena Llinares, A.; Iborra Oquendo, M. A.; Quinones Rodriguez, L. A.; Castro Ramirez, I.; Gonzalez Aquino, P.; Aguirre Huelga, M. J.

    2013-07-01

    In the new edition of the PCCRD (2011) has been established as weekly quality control testing for digital mammography equipment the analysis of artifacts from the team and defective items in the DR, the constancy of the functioning of the CAE, the accuracy of the thickness determined by the compression system, constancy in the uniformity and quality of the image. The objective of the study is to evaluate data collected during the first year of operation of the equipment. (Author)

  12. Role of the medical physicist in quality control in diagnostic x-ray departments

    International Nuclear Information System (INIS)

    Cameron, J.R.

    1973-01-01

    Medical physicists can play a role in education of future radiologists and technologists by teaching quality control needs and techniques. He or she can also provide service to the diagnostic section by establishing a quality control program. Finally, the medical physicist can play an important role in the development of simple and inexpensive techniques for quality control by radiological technologists. The ongoing work at the University of Wisconsin in this area is to provide quality control in measurement of the effective kVcp, the measurement of the effective focal spot size, the performance of the processing equipment, the output in mR/mAs, and the measurement of the half-value-layer and the total filtration. (U.S.)

  13. Quality control in Department of Nuclear Medicine, Clinical Center Banja Luka, RS, Bosnia and Herzegovina

    International Nuclear Information System (INIS)

    Goran Vuleta

    2007-01-01

    Complete test of publication follows. The aim of this work is to give a review of situations in the Department of Nuclear Medicine in Banja Luka related to quality control. We must perform daily, weekly and monthly control of equipment in the Department of Nuclear Medicine, and we must keep records. In our Department we have equipment from different producers and different year of production: 3 gamma cameras (1973, 1989, 2000); 2 auto gamma counters (2000, 2006); 2 dose calibrators (1973, 2000); 1 thyroid uptake system (2000). Normally procedures for quality control are also different. The situation, according to results of quality control is good. All equipment is working normally and with good performance (except one gamma camera - a problem with hard drive), but we don't have a routine daily control and periodical control for others tests. Keeping a records is another problem. Why? 1. In Bosnia and Herzegovina we don't have Regulatory authority. That means that we don't have legislation, rules, inspection or any other regulatory instruments. 2. There is only school for nurses, we have no special school for medical technician. So, we need an education in that field. 3. Very small number of physicist in hospital, no education for medical and nuclear medicine physicist. Conclusion. Situation in Department of Nuclear Medicine in Banja Luka related to quality control is on the medium level. We are trying to put that on the higher level, but to accomplish that we need additional education for nurses (technicians) and physicist.

  14. Acquired image quality in digital industrial radiographic equipments

    International Nuclear Information System (INIS)

    Oliveira, Cristiane de Queiroz; Lopes, Ricardo Tadeu; Oliveira, Davi F.

    2008-01-01

    The computerized radiographic application in the industrial area is a recent event. The imaging plate is the equipment used as imaging receiver during the exposition radiographic technique, which consists of a flexible photostimulable phosphor screen, capable of storing the photons energy of the incident X and γ rays and of a reading unit which uses a laser device to stimulate a visible light. As two types of phosphor screen are manufactured, one for general use (General Plate - GP) and another one for specific using (High Resolution-HR), one of the objectives of this study was to evaluate the spatial resolution capability in both plates using the Kodak equipment. Furthermore, equipment from different makers, Kodak and General Electric Company - GE, were compared. Two phosphor screen HR were used as the main objective of this study. Imaging Quality Indicators - IQI were used to evaluate the spatial resolution of the images in accordance with ASME and DIN standard. The results show that after evaluating the GP and HR Kodak plates, the HR plate was capable of showing a larger resolution of details. However, after evaluating the performance of the HR Kodak plate and GE plate, over the same acquisition condition and with the same size of the laser focal set of 87 μm, the results show a superiority in the GE equipment used for industrial radiographic, mainly for processed images in each specific ambient of digital processing and its performance in meeting satisfactorily the ASME code and the DIN standard. (author)

  15. Quality assurance in a cask fleet parts control system

    International Nuclear Information System (INIS)

    Fernandez, C.; McCreery, P.N.; Shappert, L.B.

    1991-01-01

    Applicable portions of the eighteen Quality Assurance criteria of Subpart H, 10 CFR 71 are incorporated into a relational data base system which has been designed to manage the spare parts control system for a fleet of spent nuclear fuel casks. The system includes not only parts in warehouse storage but parts in use in the field plus casks, ancillary equipment, test equipment, support devices, and even personnel. It provides a high degree of assurance that any device for which a condition for certification has expired will be flagged for recertification testing or removal from service well before the critical date

  16. Chlorine dioxide as a disinfectant for Ralstonia solanacearum control in water, storage and equipment

    Directory of Open Access Journals (Sweden)

    Popović Tatjana

    2016-01-01

    Full Text Available Brown rot or bacterial wilt caused by bacterium Ralstonia solanacearum is the main limiting factor in potato production. Quarantine measures are necessary to avoid spread of disease to disease-free areas. R. solanacearum has been shown to contaminate watercourses from which crop irrigation is then prohibited causing further potential losses in yield and quality. The bacteria also spread via surfaces that diseased seed potatoes come into contact with. This study showed bactericidal activity of chlorine dioxide (CIO2 on R. solanacearum for disinfection of water, surface and equipment. The results showed that CIO2 solution at concentration of 2 ppm at 30 minutes of exposure time had bactericidal effect for disinfection of water. For surface and equipment disinfection, concentration of 50 ppm showed total efficacy at 30 min and 5 sec exposure time, respectively. Results suggest that use of CIO2 as a disinfectant has a potential for control of brown rot pathogen in water, storage and equipment.

  17. Quality control of pesticide products

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-15

    In light of an established need for more efficient analytical procedures, this publication, which documents the findings of an IAEA coordinated research project (CRP) on “Quality Control of Pesticide Products”, simplifies the existing protocol for pesticide analysis while simultaneously upholding existing standards of quality. This publication includes both a report on the development work done in the CRP and a training manual for use by pesticide analysis laboratories. Based on peer reviewed and internationally recognized methods published by the Association of Analytical Communities (AOAC) and the Collaborative International Pesticides Analytical Council (CIPAC), this report provides laboratories with versatile tools to enhance the analysis of pesticide chemicals and to extend the scope of available analytical repertoires. Adoption of the proposed analytical methodologies promises to reduce laboratories’ use of solvents and the time spent on reconfiguration and set-up of analytical equipment.

  18. Quality control of pesticide products

    International Nuclear Information System (INIS)

    2009-07-01

    In light of an established need for more efficient analytical procedures, this publication, which documents the findings of an IAEA coordinated research project (CRP) on “Quality Control of Pesticide Products”, simplifies the existing protocol for pesticide analysis while simultaneously upholding existing standards of quality. This publication includes both a report on the development work done in the CRP and a training manual for use by pesticide analysis laboratories. Based on peer reviewed and internationally recognized methods published by the Association of Analytical Communities (AOAC) and the Collaborative International Pesticides Analytical Council (CIPAC), this report provides laboratories with versatile tools to enhance the analysis of pesticide chemicals and to extend the scope of available analytical repertoires. Adoption of the proposed analytical methodologies promises to reduce laboratories’ use of solvents and the time spent on reconfiguration and set-up of analytical equipment

  19. Comparison of studies realized with quality control and without it in nuclear medicine

    International Nuclear Information System (INIS)

    Manzo, Aisa

    2001-01-01

    SPECT studies are revised, either cerebral or cardiac, showing, in the first place, the radiopharmaceuticals used with their radio chemical characteristics; afterwards excellent quality studies are compared with studies presenting defects attributable no to the patient pathology but to a flaw in the quality control of equipment being used [es

  20. Implementation of quality assurance and quality control in the Nuclear Analytical Laboratory of the Estonian Radiation Protection Centre

    International Nuclear Information System (INIS)

    Koeoep, T.; Jakobson, E.

    2002-01-01

    The Analytical Laboratory of the Estonian Radiation Protection Centre is in the process of implementing the system of Quality Assurance (QA) and Quality Control (QC) in the framework of the IAEA TC Project RER/2/004/ 'QA/QC of Nuclear Analytical Techniques'. The draft Quality Manual with annexes has been prepared accordingly to the ISO 17025 Guide, documents and other printed material delivered on the seminars of the project. The laboratory supply has been supplemented with necessary equipment for guaranteeing of quality. Proficiency testing included in the project has been performed successfully. (author)

  1. Quality control of conventional radiographic facilities in Kinshasa

    International Nuclear Information System (INIS)

    Woto, M.L.; Lukanda, M.V.; Mulumba, L.C.P.; Palangu

    2009-01-01

    The continuous development of medical applications of ionizing radiation, due to the benefit derived by diagnostic or therapeutic patients, their diversity, ease of implementation, explains the importance of medical exposure. The latter is currently the leading cause of human exposure to artificial origin. The purpose of this study is to contribute to the optimization of radiographic facilities in the city of Kinshasa. This study has revealed that city of Kinshasa has an average of 122 medical training with conventional radiology facilities distributed in six districts of health. Of the 122 facilities, only 30 (or 24.59%) are controlled from the point of view of quality assurance. Some generators and X-ray tubes are respectively controlled adjustment and de centered, and other devices are cannibalized. So, nationally and particularly in Kinshasa, quality control equipment and diagnostic facilities is at a generally delayed compared with international recommendations of X W. Major efforts must be made at government level to raise awareness and establish a quality assurance program in diagnostic radiology. An awareness of the entire medical profession and the competent administrative authorities of medical devices could be beneficial to the quality of care delivered to patients, limiting radiation exposure and improving image quality and only the financial balance of the health sector. The delivery of quality care passes through the justification of acts, the development and dissemination of good practice references and the establishment of quality control radiological installations.

  2. In-house quality audit and benefits of some quality control procedures in the quality assurance of TL dosimetry system at NRPB

    International Nuclear Information System (INIS)

    Dutt, J.C.

    1993-01-01

    A number of Quality Control (QC) procedures have been introduced into the running and operation of the NRPB personal monitoring services. Those described here apply to the whole-body TL dosimetry system. These QC procedures comprise Quality Assurance (QA) of incoming raw materials and equipment, reader stabilisation, daily, routine and periodic QA checks on all phases of the service. In-house quality audit, periodic internal and external 'blind QA checks' on the dosimetry system as a whole have assured the continuing high quality and reliability of the NRPB TL dosimetry service for assessing body and skin doses of radiation workers from external photon and beta radiations. (author)

  3. CHALLENGES IN SETTING UP QUALITY CONTROL IN DIAGNOSTIC RADIOLOGY FACILITIES IN NIGERIA.

    Science.gov (United States)

    Inyang, S O; Egbe, N O; Ekpo, E

    2015-01-01

    The Nigerian Nuclear Regulatory Authority (NNRA) was established to regulate and control the use of radioactive and radiation emitting sources in Nigeria. Quality control (QC) on diagnostic radiology equipment form part of the fundamental requirements for the authorization of diagnostic radiology facilities in the Country. Some quality control tests (output, exposure linearity and reproducibility) were measured on the x-ray machines in the facilities that took part in the study. Questionnaire was developed to evaluate the frequencies at which QC tests were conducted in the facilities and the challenges in setting up QC. Results show great variation in the values of the QC parameters measured. Inadequate cooperation by facilities management, lack of QC equipment and insufficient staff form the major challenges in setting up QC in the facilities under study. The responses on the frequencies at which QC tests should be conducted did not correspond to the recommended standards; indicating that personnel were not familiar with QC implementation and may require further training on QC.

  4. X ray spectra and qualities for use in diagnostic radiology and equipment calibration

    International Nuclear Information System (INIS)

    Souza, Karla Cristina de

    1996-12-01

    The goal of this work was the standardization of radiation qualities of diagnostic X ray equipment of the Assay Laboratory of the Institute for Radiation Protection and Dosimetry (IRD) of the National Commission of Nuclear Energy, Brazil. X ray spectra were determined from pulse height distribution measured directly on the primary beam using a high pure planar Ge detector. A program was developed to convert pulse height distribution into radiation spectra in the range from 20 to 150 keV. X ray qualities based on those used by the 'Physikalish-Technish Bundesantalt' (PTB) primary laboratory were implanted in three radiological equipment of the Assay Laboratory. These qualities simulate radiation beams on patients submitted to typical radiological examinations. Besides the spectrometric system, a reference measurement system based on an ionization chamber calibrated in air kerma was used to establish parameters such as kilovoltage, first and second half-value layer, mean energy, effective energy and inherent filtration. Our data have shown that the implantation of these radiation qualities in the Assay Laboratory results on a metrological basis for calibration of dose measurement assemblies and kV-meters, like those used by IRD to evaluate the parameters of X ray equipment around the country. A catalogue of spectral data resulting from this work is a data bank that allows various applications like dose calculation using Monte Carlo simulation techniques. (author)

  5. Work organisation and quality control in a welding robotic cell

    OpenAIRE

    Moniz, António

    1993-01-01

    In this paper is analyzed the work organization and the forms of quality control in a robotic welding station in a company of office equipment and metal components manufacturing. The robotic cell is recent and works in two shifts. Quality and production rationalization implied in this firms the adoption of a strategy of organization of teamwork, and it is supported the collaborative tools to decrease the possibilities for errors and to improve means and methods of manufacturing. The analysis ...

  6. Some auxiliary technology equipment for ATLAS hadron calorimeter module and submodule manipulations and the quality control of the assembled module

    International Nuclear Information System (INIS)

    Budagov, Yu.; Lebedev, A.; Lomakin, Yu.; Romanov, V.; Rusakovich, N.; Shchelchkov, A.; Sisakyan, A.; Sorokina, Yu.; Topilin, N.; Kul'chitskij, Yu.

    1997-01-01

    Describing of the auxiliary technology equipment for the submodule and module manipulations is presented. The results of the 0-module beam incoming control are given. The variations of the assembled module control measurements are described. The description of the construction for the 0-module transportation is presented

  7. Development of manufacturing equipment and QC equipment for DUPIC fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Park, J.J.; Lee, J.W.; Kim, S.S.; Yim, S.P.; Kim, J.H.; Kim, K.H.; Na, S.H.; Kim, W.K.; Shin, J.M.; Lee, D.Y.; Cho, K.H.; Lee, Y.S.; Sohn, J.S.; Kim, M.J.

    1999-05-01

    In this study, DUPIC powder and pellet fabrication equipment, welding system, QC equipment, and fission gas treatment are developed to fabricate DUPIC fuel at IMEF M6 hot cell. The systems are improved to be suitable for remote operation and maintenance with the manipulator at hot cell. Powder and pellet fabrication equipment have been recently developed. The systems are under performance test to check remote operation and maintenance. Welding chamber and jigs are designed and developed to remotely weld DUPIC fuel rod with manipulators at hot cell. Remote quality control equipment are being tested for analysis and inspection of DUPIC fuel characteristics at hot cell. And trapping characteristics is analyzed for cesium and ruthenium released under oxidation/reduction and sintering processes. The design criteria and process flow diagram of fission gas treatment system are prepared incorporating the experimental results. The fission gas treatment system has been successfully manufactured. (Author). 33 refs., 14 tabs., 91 figs

  8. Special equipment for the fabrication and quality control of nuclear fuel elements

    International Nuclear Information System (INIS)

    Guse, K.; Herbert, W.; Jaeger, K.

    1989-01-01

    For the fabrication of LWR fuel elements, columns are packed of up to 4 m in length, consisting of fuel pellets with different uranium enrichment, their weight and total length to be measured prior to further processing to fuel rods. An automated column packing device has been developed for this purpose. The packing jobs and other tasks are computer-controlled, measured data are stored and are printed out for quality documentation. The forces in the springs of fuel spacers of LWR fuel elements are to be measured and compared with the standard requirements, deviations to be documented. For this task, another computer-controlled, automated device has been developed for measuring the spring forces at all required positions after positioning and fixation of the spacers. (orig./DG) [de

  9. Quality control of PET/CT

    International Nuclear Information System (INIS)

    Angelova, J.; Zajcharov, M.

    2013-01-01

    Full text: Introduction: The aim of this work is to undertake a review of the methods for checking and adjusting the computer and positron emission tomography in the Hospital 'Alexandrovska' by the attached to the equipment phantoms according to the manufacturer prescription in order to fulfill its requirements for the entry of the main parameters image within certain limits. Materials and Methods: At the start of work a check of the lasers setting for patient positioning and 'heat' of the X-ray tube scanner to better image quality were made. Daily verification procedures on the image quality of CT through the water phantom and weekly - 'air' calibration were carried out. In positron part, daily control involves setting the resolution and sensitivity of the scanner through built Ga68 phantom. When commissioning, after repair and at least once a year, it is necessary to verify the accuracy of registration of the pulses from the crystal with a water phantom of known volume and the coincidence between CT and PET image. Results: The process of quality control is interactive. The results are displayed in tables and graphically, with the goal the individual values to fall within the determined by manufacturers range and to meet the standards for image quality. If necessary, the procedure repeats several times until it is fulfilled. Conclusion: Ensuring the quality of the image in positron emission tomography combined with computed tomography, is inextricably linked to accurate and precise diagnosis of tumor processes in the human body

  10. Quality control in diagnostic mammography: myths, realities and their importance in the final image quality

    International Nuclear Information System (INIS)

    Mora Rodriguez, Patricia

    2011-01-01

    Mammography is the most used tool for early detection of breast cancer and reduce mortality from this cause. Studies with ionizing radiation it is important that be justified and provide a quality image to make the diagnosis, to get more benefits and fewer risks. The problem is the difficult to obtain an image of the breast. Therefore, the commitment to quality mammography is to maximize the contrast, definition, resolution and reliability, thus minimizing noise and dose. A mammogram performed without quality don't detect early breast cancer and the study doesn't have sense. Quality mammography requires trained and experienced staff, modern equipment and in good conditions, correct positioning, right technical factors and appropriate viewing conditions. In addition, quality programs are required to reach to ensure quality, control in testing techniques and image quality. (author) [es

  11. PACS quality control and automatic problem notifier

    Science.gov (United States)

    Honeyman-Buck, Janice C.; Jones, Douglas; Frost, Meryll M.; Staab, Edward V.

    1997-05-01

    One side effect of installing a clinical PACS Is that users become dependent upon the technology and in some cases it can be very difficult to revert back to a film based system if components fail. The nature of system failures range from slow deterioration of function as seen in the loss of monitor luminance through sudden catastrophic loss of the entire PACS networks. This paper describes the quality control procedures in place at the University of Florida and the automatic notification system that alerts PACS personnel when a failure has happened or is anticipated. The goal is to recover from a failure with a minimum of downtime and no data loss. Routine quality control is practiced on all aspects of PACS, from acquisition, through network routing, through display, and including archiving. Whenever possible, the system components perform self and between platform checks for active processes, file system status, errors in log files, and system uptime. When an error is detected or a exception occurs, an automatic page is sent to a pager with a diagnostic code. Documentation on each code, trouble shooting procedures, and repairs are kept on an intranet server accessible only to people involved in maintaining the PACS. In addition to the automatic paging system for error conditions, acquisition is assured by an automatic fax report sent on a daily basis to all technologists acquiring PACS images to be used as a cross check that all studies are archived prior to being removed from the acquisition systems. Daily quality control is preformed to assure that studies can be moved from each acquisition and contrast adjustment. The results of selected quality control reports will be presented. The intranet documentation server will be described with the automatic pager system. Monitor quality control reports will be described and the cost of quality control will be quantified. As PACS is accepted as a clinical tool, the same standards of quality control must be established

  12. Evaluation of the Beam Quality of Intraoral X-ray Equipment using Intraoral Standard Films

    International Nuclear Information System (INIS)

    Lee, Sang Sub; Kwon, Hyok Rak; Sim, Woo Hyoun; Oh, Seung Hyoun; Lee, Ji Youn; Jeon, Kug Jin; Kim, Kee Deog; Park, Chang Seo

    2000-01-01

    This study was to evaluate the beam quality of intraoral X-ray equipment used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. The study was done using the intraoral X-ray equipment used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Most of the HVLs of intraoral X-ray equipment were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANPAS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X-ray equipment should be managed in the planned and organized fashion.

  13. Universal machine ''Shtrek'' and the tractor-lifter with pneumatic-equipment control. [Auxiliary multipurpose materials handling equipment

    Energy Technology Data Exchange (ETDEWEB)

    Bal' bert, B M; Borumenskiy, V A; Lishenko, A P; Mitchenko, G A

    1982-01-01

    The machine ''Shtrek'' is described. It makes it possible to mechanize over 20 auxiliary operations: loading-unloading operations: extraction of old and deformed timbering; dissmantling of obstructions; erection of different types of timbering; making and restoring of drainage channels; laying and straightening of a drift and its leveling; assembly and disassembly of pipelines and mine equipment, etc. Depending on the type of operation, the machine has the corresponding suspended equipment. The elementary variant has a limited area of application at mines of the central region of the Dunbass. Currently a pneumatic variant of the machine ''Shtrek'' has been developed. The electric motor and the starter of the pumping equipment of the machine have been replaced by a pneumatic motor and pneumatically controlled valve KTM-50. In this case there was significant reduction in the weight of the pumping equipment and in its overall dimensions; the electric drive of the hydraulic distributors for controlling the mechanisms were replaced by simpler pneumatic ones; the logical circuit of the control system was constructed on the USEPPA elements. A specialized tractor-lifter designed for moving suspended loads is described for auxiliary operations in the near-face zone of the preparatory drifts. The machine also lifts and lowers the boom, rotates the boom by 270/sup 0/ and additionally lifts and lowers the weight-lifting hook.

  14. Control of Nuclear Materials and Special Equipment (Nuclear Safety Regulations)

    International Nuclear Information System (INIS)

    Cizmek, A.; Prah, M.; Medakovic, S.; Ilijas, B.

    2008-01-01

    Based on Nuclear Safety Act (OG 173/03) the State Office for Nuclear Safety (SONS) in 2008 adopted beside Ordinance on performing nuclear activities (OG 74/06) and Ordinance on special conditions for individual activities to be performed by expert organizations which perform activities in the area of nuclear safety (OG 74/06) the new Ordinance on the control of nuclear material and special equipment (OG 15/08). Ordinance on the control of nuclear material and special equipment lays down the list of nuclear materials and special equipment as well as of nuclear activities covered by the system of control of production of special equipment and non-nuclear material, the procedure for notifying the intention to and filing the application for a license to carry out nuclear activities, and the format and contents of the forms for doing so. This Ordinance also lays down the manner in which nuclear material records have to be kept, the procedure for notifying the State administration organization (regulatory body) responsible for nuclear safety by the nuclear material user, and the keeping of registers of nuclear activities, nuclear material and special equipment by the State administration organization (regulatory body) responsible for nuclear safety, as well as the form and content of official nuclear safety inspector identification card and badge.(author)

  15. Quality assurance in a cask fleet parts control system

    International Nuclear Information System (INIS)

    Fernandez, C.; Shappert, L.B.

    1992-01-01

    This paper discusses applicable portions of the eighteen Quality Assurance criteria of Subpart H, 10 CFR 71 which are incorporated into a relational data base system which has been designed to manage the spare parts control system for a fleet of spent nuclear fuel casks. The system includes not only parts in warehouse storage but parts in use in the field plus casks, ancillary equipment, test equipment, support devices, and even personnel. It provides a high degree of assurance that any device for which a condition for certification has expired will be flagged for recertification testing or removal from service well before the critical date

  16. Basic quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Wikstrom, Erik

    2016-01-01

    Along the route toward regular performance of Quality Control in the Diagnostic Imaging sector there are a number of balances to negotiate: Patient/Staff safety considerations vs Regulatory compliance vs Performance of modern equipment vs Clinic's Productivity. At first glance these ambitions may seem in conflict. The tests performed to meet regulatory requirements may or may not bear any semblance to real clinical measurement scenarios. And the process of collecting the data from the quality assurance tests may induce a system down- time that adversely affects the clinic's overall productivity. Furthermore, the time it takes to complete the analysis of the test data and provide the report required to take the facility back into operation is time wasted for patients waiting for a diagnostic imaging exam

  17. Radiation protection of patients and quality controls in teleradiology

    Energy Technology Data Exchange (ETDEWEB)

    Vermiglio, G.; Testagrossa, B.; Sansotta, C.; Tripepi, M.G. [Messina Univ., Dept. of Protezionistica Ambientale, Sanitaria, Sociale ed Industriale (Italy)

    2006-07-01

    Nowadays, it is well-known that tele-radiology represents the new frontier of radiodiagnostic imaging. In this case, the continuous broadening of transmission bands and the more sophisticated procedures of information packaging constitute a no negligible inducement. Moreover, standards used to convert analogical signals into the digital ones, necessary to transfer via ether radiological images and information, involve a more limited loss of information. Nevertheless, unlike the common images, in case of the X-ray diagnostic images it must take into account that the EURATOM Council Directives give the health physicist all the procedures to be followed for checking the status of X-ray equipments. In particular, the EURATOM Council Directives provide minimum criteria of acceptance for parameters that characterised the correct working of the radiological equipments and the guide lines for standardised execution of X-ray images, in order to obtain high quality information. In addiction, for maintaining such level it is necessary to adopt adequate programs of Quality Assurance. Naturally, the high quality of radiological images must be conserved after the transmission of information. So, in order to evaluate the amount of losses that can be introduced after transferring the X-ray images from source to user, the authors have carried out specific procedures in order to evaluate the quality level of the images after transmission and to compare them with the correspondent ones acquired at the equipment console. To this aim, the AAs have identified all the parameters able to verify the quality level of the images and measured the values obtained for the directly acquired images and the transferred ones. They have also considered different kinds of transmission protocols to define suitable procedures of remote quality controls. (authors)

  18. Radiation protection of patients and quality controls in teleradiology

    International Nuclear Information System (INIS)

    Vermiglio, G.; Testagrossa, B.; Sansotta, C.; Tripepi, M.G.

    2006-01-01

    Nowadays, it is well-known that tele-radiology represents the new frontier of radiodiagnostic imaging. In this case, the continuous broadening of transmission bands and the more sophisticated procedures of information packaging constitute a no negligible inducement. Moreover, standards used to convert analogical signals into the digital ones, necessary to transfer via ether radiological images and information, involve a more limited loss of information. Nevertheless, unlike the common images, in case of the X-ray diagnostic images it must take into account that the EURATOM Council Directives give the health physicist all the procedures to be followed for checking the status of X-ray equipments. In particular, the EURATOM Council Directives provide minimum criteria of acceptance for parameters that characterised the correct working of the radiological equipments and the guide lines for standardised execution of X-ray images, in order to obtain high quality information. In addiction, for maintaining such level it is necessary to adopt adequate programs of Quality Assurance. Naturally, the high quality of radiological images must be conserved after the transmission of information. So, in order to evaluate the amount of losses that can be introduced after transferring the X-ray images from source to user, the authors have carried out specific procedures in order to evaluate the quality level of the images after transmission and to compare them with the correspondent ones acquired at the equipment console. To this aim, the AAs have identified all the parameters able to verify the quality level of the images and measured the values obtained for the directly acquired images and the transferred ones. They have also considered different kinds of transmission protocols to define suitable procedures of remote quality controls. (authors)

  19. Quality and safety based management of radiological and clinical equipment

    International Nuclear Information System (INIS)

    Arora, S.; Saini, P.S.

    2001-01-01

    TQM (Total quality management) is the 'buzz' acronym expected in almost every aspect of industrial manufacturing, product development and services solicited by the outside agencies. The correct management of the many technological resources in health institutions in terms of efficiency, effectiveness and safety is a necessity in view of the criteria on which modern medicine is based. Almost all activities -be they diagnostic, therapeutic and rehabilitative - carried out within a modern hospital are based on widespread application of equipment and technology, the efficiency of which can directly influence the quality of service offered to the patient

  20. Physical aspects of quality assurance in radiotherapy: A protocol for quality control

    International Nuclear Information System (INIS)

    Aguirre, J.F.; Alfonso-Laguardia, R.; Andreo, P.; Brunetto, M.; Marenco-Zuniga, H.; Gutt, F.; Torres-Calderon, A.

    2000-06-01

    In consistency with the increasing requests from Member States for establishing radiotherapy programmes, an IAEA Technical Co-operation project was initiated in Latin America aimed at improving the physical aspects (as a complement to the clinical issues) of quality assurance in radiotherapy; this ARCAL XXX project (RLA/6/032) was classified as a Model Project of the IAEA. Among the important outcomes of the project were (i) the training of a considerable number of medical physicists in hospitals of the region, (ii) the development of a protocol for quality control procedures, and (iii) the organization of quality audit site visits (to the participant countries) where the implementation in hospitals of the developed quality control procedures is verified. The present publication is the protocol for quality control of the physical aspects of radiotherapy. It contains detailed procedures on what should be measured by a medical physicist in a radiotherapy treatment unit and related equipment, and how this should be made. The latter is made through several appendices, which make the document rather unique. The protocol was developed by medical physicists of the region for the professionals of the region, and it is the first document of this kind ever written in Spanish. A training course was organized in November 1998 (Havana, Cuba) where its practical implementation was taught. There are plans to have this document translated into different languages for the various regions having similar TC projects. (author)

  1. Improving electrical equipment and control systems for shield integrated mining systems

    Energy Technology Data Exchange (ETDEWEB)

    Rabinovich, Z.M.; Starikov, B.Ya.; Kibrik, I.S.

    1984-06-01

    The design and operation are discussed for electrical equipment and control systems for the 1AShchM, the ANShch and the 2ANShch shield integrated face systems consisting of shield supports, coal plow and chain conveyor. The shield system is used for mining inclined and steep coal seams endangered by coal dust explosions, methane or rock bursts. Control and electrical system for 3 types of shield face mining systems is similar. It cuts energy supply when methane content at working faces exceeds the maximum permissible level, controls haulage rate and cutting rate of a coal plow, controls operation of shield supports (using the Sirena system), controls dust suppression system and its water consumption. The system is also equipped with communications equipment. Tests of the control and electrical system for the integrated shield system carried out in the im. Gagarin mine in the Ukraine are described. The VAUS III control system developed by Dongiprouglemash was tested.

  2. Quality control programme for radiotherapy

    International Nuclear Information System (INIS)

    Campos de Araujo, A.M.; Viegas, C.C.B.; Viamonte, A.M.

    2002-01-01

    A 3 years pilot programme started in January 2000 with 33 philanthropic cancer institutions that provides medical services to 60% of the patients from the national social security system. Brazil has today 161 radiotherapy services (144 operating with megavoltage equipment). These 33 institutions are distributed over 19 Brazilian states. The aim of this programme is: To create conditions to allow the participants to apply the radiotherapy with quality and efficacy; To promote up dating courses for the physicians, physicists and technicians of these 33 Institutions. With the following objectives: To recommend dosimetric and radiological protection procedures in order to guarantee the tumor prescribed dose and safe working conditions; To help in establishing and implementing these procedures. The main activities are: local quality control evaluations, postal TLD audits in reference conditions, postal TLD audits in off axis conditions and training. The local quality control program has already evaluated 22 institutions with 43 machines (25 Co-60 and 18 linear accelerators). In these visits we perform dosimetric, electrical, mechanical and safety tests. As foreseen, we found more problems among the old Co-60 machines i.e., field flatness, size, symmetry and relative output factors; lasers positioning system alignment; optical distance indicator; radiation and light field coincidence; optical and mechanical distance indicators agreement, than among the linear accelerators i.e., field flatness and size; lasers positioning system alignment; tray interlocking and wedge filter factors

  3. Use of Industrial Components in SL/BT Equipment Controls

    CERN Document Server

    Carlier, E

    1999-01-01

    The control system of all SPS target stations, beam absorbers and other aperture limiting devices is presently being refurbished, using solely standard industrial hardware and software components. SIEMENS Simatic S7-300 programmable logic controllers serve as equipment controllers. They are connected through Profibus to a WinNT front-end running the SIEMENS WinCC SCADA package which acts as local controller and gateway for remote access. A variant configuration, where the PLCs are directly linked to Ethernet, has been used for controlling the SPS Q measurement kickers. These and some other SL/BT projects will be reviewed where fully off-the-shelf components have been successfully integrated into the SL accelerator controls infrastructure. The arguments leading to the various technical choices will be laid down including a report of the experience gained. Finally, the presentation will address the perspective and current ideas for using industrial components in controlling SL/BT equipment during the LHC era.

  4. Establishment for Nuclear Equipment: Overview

    International Nuclear Information System (INIS)

    Pracz, J.

    2001-01-01

    Full text: The activity of ZdAJ in 2000 was focused on realisation of the Government-Ordered Project - 6/15 MeV Accelerator. The realisation was accomplished in two stages: - stage I should result in deriving principal operational parameters of the accelerator - stage 2 will result in full implementation of the control system providing optimum control of the equipment and automatic maintaining of its parameters. Within the frames of the first stage, a klystron modulator panel was finished and the design documentation of the mechanical supporting structure, the arm, accelerating structure, collimator and control panel were advanced. Manufacturing of the above sub-units in the workshop has started. In the frames of the Specific Project of the State Committee for Scientific Research, the improvement of Neptun lOPC accelerator was undertaken. The read-out of the monitor dose with atmospheric pressure and ambient temperature compensation has been introduced. New filters for equalising the photon and electron beam and new wedge filters have been designed. Changes in programming have been introduced, which improve the patient's safety by eliminating possible personnel errors and increase the accuracy of radiation fields read-out. In 2000 ZdAJ progressed in development of the Quality System conforming EN-ISO 9001 Standard by including the provisions of EN 46001 Standard. The Standard EN 46001: ''Quality Systems - Medical Equipment''. Detailed requirements related to application of EN ISO 9001 is an European Quality Standard extending the provisions of EN ISO 9001 Standard over the manufacturers of medical equipment. (author)

  5. Quality control activities in the environmental radiology laboratory

    International Nuclear Information System (INIS)

    Llaurado, M.; Quesada, D.; Rauret, G.; Tent, J.; Zapata, D.

    2006-01-01

    During the last twenty years many analytical laboratories have implemented quality assurance systems. A quality system implementation requires documentation of all activities (technical and management), evaluation of these activities and its continual improvement. Implementation and adequate management of all the elements a quality system includes are not enough to guarantee quality of the analytical results generated at a time. That is the aim of a group of specific activities labelled as quality control activities. The Laboratori de Radiologia Ambiental (Environmental Radiology Laboratory; LRA) at the University of Barcelona was created in 1984 to carry out part of the quality control assays of the Environmental Radiology Monitoring Programs around some of the Spanish nuclear power plants, which are developed by the Servei Catala d'Activitats Energetiques (SCAR) and the Consejo de Seguridad Nuclear (CSN), organisations responsible for nuclear security and radiological protection. In these kind of laboratories, given the importance of the results they give, quality control activities become an essential aspect. In order to guarantee the quality of its analytical results, the LRA Direction decided to adopt the international standard UNE-EN ISO/IEC 17025 for its internal quality system and to accreditate some of the assays it carries out. In such as system, it is established, the laboratory shall monitor the validity of tests undertaken and data shall be recorded in such a way that trends are detectable. The present work shows the activities carried out in this way by the LRA, which are: Equipment control activities which in the special case of radiochemical techniques include measurement of backgrounds and blanks as well as periodical control of efficiency and resolution. Activities to assure the specifications settled by method validation, which are testing of reference materials and periodical analysis of control samples. Evaluation of the laboratory work quality

  6. Quality of care and investment in property, plant, and equipment in hospitals.

    OpenAIRE

    Levitt, S W

    1994-01-01

    OBJECTIVE. This study explores the relationship between quality of care and investment in property, plant, and equipment (PPE) in hospitals. DATA SOURCES. Hospitals' investment in PPE was derived from audited financial statements for the fiscal years 1984-1989. Peer Review Organization (PRO) Generic Quality Screen (GQS) reviews and confirmed failures between April 1989 and September 1990 were obtained from the Massachusetts PRO. STUDY DESIGN. Weighted least squares regression models used PRO ...

  7. Quality control as a way to find out doses as low as reasonably practicable in mammography systems

    International Nuclear Information System (INIS)

    Hwang, S.F.; Nogueira, M.S.; Peixoto, J.E.; Paraguay, Y.V.

    2008-01-01

    The breast cancer is the most common neoplasm amongst women. Mammography is an essential tool for diagnosis and early detection of this disease. In order to guarantee the effectiveness of the diagnosis taking into account the patient radiation safety, it is mandatory to perform the quality control tests of the mammographic equipment. The main objective of this work has been to evaluate the relationship between the image quality and the total performance of the medical equipment. Primary data were collected from several radiological facilities during the quality control inspections performed by the local regulatory authorities of the Brazilian health, the National Commission of Nuclear Energy and the Brazilian College of Radiology. The main important functioning parameters were evaluated as well as the image quality using the simulator 'phantom mama'. In spite of the fact that high quality images could suggest delivering large radiation doses to patients it has been demonstrated that it is possible to acquire images with a good quality for clinical diagnosis without delivering high doses if the system is working properly. It has been concluded that following an optimized quality control program could avoid the complex dosimetric studies to guarantee good images quality. (author)

  8. Robust control investigations for equipment loaded panels

    DEFF Research Database (Denmark)

    Aglietti, G.S.; Langley, R.S.; Rogers, E.

    1998-01-01

    This paper develops a modelling technique for equipment load panels which directly produces (adequate) models of the underlying dynamics on which to base robust controller design/evaluations. This technique is based on the use of the Lagrange's equations of motion and the resulting models...

  9. Current State Park General Radiology in the region of Murcia. 18 years of quality control

    International Nuclear Information System (INIS)

    Vera Sanchez, J. A.; Buades Forner, M. J.; Tobarra Gonzalez, B. M.

    2011-01-01

    This paper examines the latest campaign for quality control of technical parameters of equipment carried out by l Radiological Protection Service of the Hospital Universitario Virgen de la Arrixaca, and compare the present results with those presented by this same service Congress of the Spanish Society of Medical Physics in 1993. [1], corresponding to the first quality control campaign conducted in 1992. (Author) 2 refs.

  10. Quality control in diagnostic radiology - patient dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Prlic, I; Radalj, Z; Brumen, V; Cerovac, H [Institute for Medical Research and Occupational Health, Laboratory for Radiation Protection and Dosimetry, Zagreb (Croatia); Gladic, J [Institute for Physics, Laboratory for Solid State Physics, Zagreb (Croatia); Tercek, V [Clinical Hospital Sisters of Mercy, Health Physics Department, Zagreb (Croatia)

    1997-12-31

    In order to establish the Quality Criteria for diagnostic radiographic images in the radiology departments in Republic of Croatia we have started the several Quality Control projects on the field. The measurements are performed according to some methodology recommendations in our law but the methodology, measurement principles, measurement equipment, phantoms, measurable parameters for the good use by radiographers, statistical and numerical evaluation, dosimetric philosophy etc. where first recognized as a private/or group hazard of each person involved in the procedure of evaluation of diagnostic radiology images/diagnosis. The important quality elements of the imaging process are: the diagnostic quality of the radiographic image, the radiation dose to the patient and the choice of the radiographic technique. This depends on the x-ray unit (tube) radiation quality, image processing quality and final image evaluation quality. In this paper we will show how the Quality Control measurements can be easily connected to the dose delivered to the patient for the known diagnostic procedure and how this can be used by radiographers in their daily work. The reproducibility of the x-ray generator was checked before the service calibration and after the service calibration. The table of kV dependence and output dose per mAs was calculated and the ESD (entrance surface dose) was measured/calculated for the specific diagnostic procedure. After the phantom calculation were made and the dose prediction for the given procedure was done, measurements were done on the patients (digital dosemeters, TLD and film dosemeter combinations). We are claiming that there is no need to measure each patient if the proper Quality Control measurements are done and the proper table of ESD for each particular x-ray tube in diagnostic departments is calculated for the radiographers daily use. (author). 1 example, 1 fig., 13 refs.

  11. Quality Control and Quality Assurance of Radiation Oncology

    International Nuclear Information System (INIS)

    Abaza, A.

    2016-01-01

    Radiotherapy (RT) has played important roles in cancer treatment for more than one century. The development of RT techniques allows high-dose irradiation to tumors while reducing the radiation doses delivered to surrounding normal tissues. However, RT is a complex process and involves understanding of the principles of medical physics, radiobiology, radiation safety, dosimetry, radiation treatment planning, simulation and interaction of radiation with other treatment modalities. Each step in the integrated process of RT needs quality control and quality assurance (QA) to prevent errors and to ensure that patients will receive the prescribed treatment correctly. The aim of this study is to help the radio therapists in identifying a system for QA that balances patient safety and quality with available resources. Recent advances in RT focus on the need for a systematic RT QA program that balances patient safety and quality with available resources. It is necessary to develop more formal error mitigation and process analysis methods, such as failure mode and effect analysis (FMEA), to focus available QA resources optimally on the process components. External audit programs are also effective. Additionally, Clinical trial QA has a significant role in enhancing the quality of care. The International Atomic Energy Agency (IAEA) has operated both an on-site and off-site postal dosimetry audit to improve practice and to assure the dose from RT equipment. Both postal dosimetry audit and clinical trial RTQA, especially for advanced technologies, in collaboration with global networks, will serve to enhance patient safety and quality of care

  12. Electrical and control equipment in nuclear power plants. Problems when replacing aging equipment

    International Nuclear Information System (INIS)

    Nordling, Anna; Haakansson, Goeran

    2012-01-01

    Interoperability between different technical systems is more complicated when old and new technology meet, such as between analog and digital technology. New electrical and I and C equipment is selected with consideration to simplify and improve the compatibility and interoperability. The original construction of nuclear power plants with electricity and I and C equipment had more natural interfaces. Generally experienced guidance, to the management of interoperability and interfaces, feels insufficient. Skills transfer programs are identified as a major need, as more and more important personnel are retiring and important information is lost with them. Lack of appropriate skills directly affects the ability to produce accurate and complete requirements specification. Failure modes of newer electrical and I and C equipment are perceived as more complex than the older equipment. When choosing equipment, attempts are made to minimize unnecessary features, to reduce the number of potential failure modes. There is a lack of consistent understanding of the meaning of robustness in electrical technology and I and C technology, in the nuclear plant engineering departments. The overall picture is that the robustness has worsened since the facilities were built. The Swedish nuclear power plants have an internal organizational structure with separated client and support organization. This splits the nuclear organization into two distinct parts which threaten to separate the two entities focus. Engineering departments at the Swedish nuclear power plants express a need for increased expertise in the client organization (blocks). Competence requested is for example, system knowledge to facilitate and enhance the quality of the initial analysis performed in the blocks. Suppliers receive more recently larger turnkey projects, both to minimize costs but also to minimize the interfaces and co-function problems. This, however, heightens demands for knowledge transfer between

  13. The equipment access software for a distributed UNIX-based accelerator control system

    International Nuclear Information System (INIS)

    Trofimov, Nikolai; Zelepoukine, Serguei; Zharkov, Eugeny; Charrue, Pierre; Gareyte, Claire; Poirier, Herve

    1994-01-01

    This paper presents a generic equipment access software package for a distributed control system using computers with UNIX or UNIX-like operating systems. The package consists of three main components, an application Equipment Access Library, Message Handler and Equipment Data Base. An application task, which may run in any computer in the network, sends requests to access equipment through Equipment Library calls. The basic request is in the form Equipment-Action-Data and is routed via a remote procedure call to the computer to which the given equipment is connected. In this computer the request is received by the Message Handler. According to the type of the equipment connection, the Message Handler either passes the request to the specific process software in the same computer or forwards it to a lower level network of equipment controllers using MIL1553B, GPIB, RS232 or BITBUS communication. The answer is then returned to the calling application. Descriptive information required for request routing and processing is stored in the real-time Equipment Data Base. The package has been written to be portable and is currently available on DEC Ultrix, LynxOS, HPUX, XENIX, OS-9 and Apollo domain. ((orig.))

  14. Physicians, radiologists, and quality control

    International Nuclear Information System (INIS)

    Payne, W.F.

    1973-01-01

    Factors involved in quality control in medical x-ray examinations to achieve the least possible exposure to the patient are discussed. It would be hoped that film quality will remain in the position of paramount importance that it must in order to achieve the greatest amount of diagnostic information on each radiographic examination. At the same time, it is hoped that this can be done by further reducing the exposure of the patient to ionizing radiation by the methods that have been discussed; namely, education of the physician, radiologist, and technologist, modern protective equipment and departmental construction, efficient collimation whether automatic or manual, calibration and output measurement of the radiographic and fluoroscopic units, ongoing programs of education within each department of radiographic facility, film badge monitoring, education of and cooperation with the nonradiologic physician, and hopefully, more intensive programs by the National and State Bureaus and Departments of Radiological Health in education and encouragement to the medical community. (U.S.)

  15. Procurement and quality control of components important to safety in nuclear engineering projects

    International Nuclear Information System (INIS)

    Zhang Zhihua; Zhang Yiyun

    2006-01-01

    The procurement and quality control of components is a very important work in the nuclear engineering. This paper introduces the project management techniques, such as how to make a plan of components purchase in nuclear engineering. This paper discussed the classification of components, evaluation of the potential suppliers, invitation of bids, exchange of design details with the suppliers, quality assurance and quality assurance audit, and the equipment checks before acceptance and some engineering experiences. (authors)

  16. Design, analysis, and interpretation of field quality-control data for water-sampling projects

    Science.gov (United States)

    Mueller, David K.; Schertz, Terry L.; Martin, Jeffrey D.; Sandstrom, Mark W.

    2015-01-01

    The process of obtaining and analyzing water samples from the environment includes a number of steps that can affect the reported result. The equipment used to collect and filter samples, the bottles used for specific subsamples, any added preservatives, sample storage in the field, and shipment to the laboratory have the potential to affect how accurately samples represent the environment from which they were collected. During the early 1990s, the U.S. Geological Survey implemented policies to include the routine collection of quality-control samples in order to evaluate these effects and to ensure that water-quality data were adequately representing environmental conditions. Since that time, the U.S. Geological Survey Office of Water Quality has provided training in how to design effective field quality-control sampling programs and how to evaluate the resultant quality-control data. This report documents that training material and provides a reference for methods used to analyze quality-control data.

  17. Long-term preventive maintenance of instrumentation control equipment for PWR plants

    International Nuclear Information System (INIS)

    Sugitani, S.; Nanba, M.

    2006-01-01

    Since the PWR plants in Japan have been operated more than 30 years, main instrumentation control equipment of analog systems has been renewed to digital control systems. Renewal works had to be done in short period within periodical inspection term and for several facilities. The Mitsubishi LTD group had been provided with these market needs by its digital control system (MELTAC-NplusR 3) applicable to main instrumentation control equipment for primary and secondary systems and had already finished the renewal for practical plants. (T. Tanaka)

  18. [Quality process control system of Chinese medicine preparation based on "holistic view"].

    Science.gov (United States)

    Wang, Ya-Qi; Jiao, Jiao-Jiao; Wu, Zhen-Feng; Zheng, Qin; Yang, Ming

    2018-01-01

    "High quality, safety and effectiveness" are the primary principles for the pharmaceutical research and development process in China. The quality of products relies not only on the inspection method, but also on the design and development, process control and standardized management. The quality depends on the process control level. In this paper, the history and current development of quality control of traditional Chinese medicine (TCM) preparations are reviewed systematically. Based on the development model of international drug quality control and the misunderstanding of quality control of TCM preparations, the reasons for impacting the homogeneity of TCM preparations are analyzed and summarized. According to TCM characteristics, efforts were made to control the diversity of TCM, make "unstable" TCM into "stable" Chinese patent medicines, put forward the concepts of "holistic view" and "QbD (quality by design)", so as to create the "holistic, modular, data, standardized" model as the core of TCM preparation quality process control model. Scientific studies shall conform to the actual production of TCM preparations, and be conducive to supporting advanced equipment and technology upgrade, thoroughly applying the scientific research achievements in Chinese patent medicines, and promoting the cluster application and transformation application of TCM pharmaceutical technology, so as to improve the quality and effectiveness of the TCM industry and realize the green development. Copyright© by the Chinese Pharmaceutical Association.

  19. Implementation of a quality control program of the equipment of the nuclear medicine services in Chile; Implementacion de un programa de control de calidad del equipamiento de los servicios de medicina nuclear de Chile

    Energy Technology Data Exchange (ETDEWEB)

    Astudillo, R.; Diaz, G.; Ferreira, A.; Garcia, M.; Hermosilla, A.; Pacheco, F.; Vasquez, M. [Universidad de la Frontera, Departamento de Ciencias Fisicas, Av. Francisco Salazar 1145, Temuco 4811230, Araucania (Chile); Coca, M., E-mail: ferreira.sdgr@gmail.com [MedScan Concepcion, Paicavi 270, Concepcion (Chile)

    2014-08-15

    Now days in Chile there are more of 43 Nuclear Medicine centers; most of them have gamma cameras in order to study physiological process in diagnostic and treatment of patients pathologies. This requires having the equipment in optimal operating condition and it is ensured with quality control programs that are based on a series of tests relating to protocols, such as TECDOC-602 y AAPM No.6. Planar test often applied in gamma cameras including: spatial resolution, spatial linearity, sensitivity and uniformity. SPECT tests consider: tomography uniformity, rotation center tomography resolution and total performance. The tests in dose calibrator are: background measurement, accuracy, precision, linearity and reproducibility. The tests above require the use of radioactive sources and specific simulators patterns or phantom based on international standards such as The National Electrical Manufacturers Association (Nema), International Atomic Energy Agency (IAEA) and The American Association of Medical Physics (AAPM). In this work we carried out several tests of quality control in a Nuclear Medicine Center of Temuco and we propose to implement the applied methodology in others similar Chilean centers. (author)

  20. Radioisotopic methods for quality control of works and studies while constructing foundations and underground structures

    International Nuclear Information System (INIS)

    Smorodinov, M.I.

    1980-01-01

    The data on the use of radioisotope methods of quality control of various kinds of construction works when building foundations and underground constructions and when carrying out scientific research, are presented. Devices and equipment are described, their block diagrams are presented. The experience in using radioisotope devices to control the quality of construction works, is presented. The problems of economic effectivenes of works using radioisotope devices are solved

  1. The Evaluation of the Equipment and Quality of the Public Space of Poznań

    Directory of Open Access Journals (Sweden)

    Budner Waldemar W.

    2016-06-01

    Full Text Available The article defines the notion of public space and attempts to explain its forms and roles. The article realizes two cognitive goals: the evaluation of the equipment of public spaces in Poznań with the selected elements of landscape architecture and the quality of those spaces. Empirical research was conducted in the form of a survey addressed at 300 respondents. The research activities conducted in the course of work allow for the formulation of the following conclusions: the quality of life in a city depends on the condition of equipment of public space; the elements of landscape architecture make the public space of Poznań more attractive (contribute to its functionality, increase the aesthetics of urban space; the condition of the equipment of public space with landscape architecture is evaluated as good; the users of the public space in Poznań pointed out the problem of advertising pillars, advertisements and signboards, public toilets and the insufficient number of seats.

  2. A Digital Power Quality Monitoring Equipment Designed for Digital Substation

    Science.gov (United States)

    Li, Wei; Wang, Xin; Geng, Jiewen

    2018-01-01

    Taking into account both current status and development trend of digital substation, this paper proposed a design of a new multi-channelled digital power quality monitoring equipment with high compatibility. The overall functional structure, hardware architecture, software architecture, interface architecture and some key techniques such as IEC 61850 modelling of transient event and harmonic measurement method under the condition of non-synchronous sampling are described in this paper.

  3. Image quality control of mammography equipment -Mammography System MX-300- of the Teachers Hospital of UNSA and dose measurement in breasts with radiographic films

    International Nuclear Information System (INIS)

    Quispe F, L. K.; Vega R, J.

    2015-10-01

    This work is part of medical imaging for the evaluation of quality. Will have an accredited breast phantom Rmi-156 that allows evaluating the image quality of mammography equipment and through a series of techniques and processes that will submit to mammography films we obtain characteristic curves, which allows to evaluate different parameters that will serve for our study. Images were acquired with different k Vp and m As of the equipment, also with different thicknesses of the breast phantom. Also we want to use the lowest possible dose for obtaining our images. In this paper we develop a simple protocol that aims to unify the conditions under which are acquired the images for later evaluation. By obtaining these characteristic curves demonstrate that the Kodak film is the most suitable for our study because it requires lower dose for obtaining our images. (Author)

  4. Shifting Control Algorithm for a Single-Axle Parallel Plug-In Hybrid Electric Bus Equipped with EMT

    Directory of Open Access Journals (Sweden)

    Yunyun Yang

    2014-01-01

    Full Text Available Combining the characteristics of motor with fast response speed, an electric-drive automated mechanical transmission (EMT is proposed as a novel type of transmission in this paper. Replacing the friction synchronization shifting of automated manual transmission (AMT in HEVs, the EMT can achieve active synchronization of speed shifting. The dynamic model of a single-axle parallel PHEV equipped with the EMT is built up, and the dynamic properties of the gearshift process are also described. In addition, the control algorithm is developed to improve the shifting quality of the PHEV equipped with the EMT in all its evaluation indexes. The key techniques of changing the driving force gradient in preshifting and shifting compensation phases as well as of predicting the meshing speed in the gear meshing phase are also proposed. Results of simulation, bench test, and real road test demonstrate that the proposed control algorithm can reduce the gearshift jerk and the power interruption time noticeably.

  5. Construction of a physical phantom for quality control of digital radiography images

    International Nuclear Information System (INIS)

    Santos, Tayline T.; Azevedo, Priscila F.B. de; Vieira, Jose Wilson; Oliveira, Alex C.H. de; Lima, Fernando R. Andrade

    2014-01-01

    The advancement of technology in recent years has the production of increasingly sophisticated devices, in order thus to obtain medical images with high technical level and also facilitate the operation of the equipment. The phantoms were created to ensure a more accurate diagnosis with the minimum dose without exposing patients. Also, to obtain data and verify the performance of a radiography system with a view to ensuring the quality control standards. The objective of this paper is to present and validate a methodology for the construction of a phantom for the control of digital quality radiographic image. (author)

  6. Construction of a physical phantom for quality control of digital radiography images

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Tayline T.; Azevedo, Priscila F.B. de; Vieira, Jose Wilson, E-mail: taylinetyene@hotmail.com, E-mail: priscilafbrasil@yahoo.com.br [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFPE), Recife, PE (Brazil); Oliveira, Alex C.H. de; Lima, Fernando R. Andrade, E-mail: falima@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2014-07-01

    The advancement of technology in recent years has the production of increasingly sophisticated devices, in order thus to obtain medical images with high technical level and also facilitate the operation of the equipment. The phantoms were created to ensure a more accurate diagnosis with the minimum dose without exposing patients. Also, to obtain data and verify the performance of a radiography system with a view to ensuring the quality control standards. The objective of this paper is to present and validate a methodology for the construction of a phantom for the control of digital quality radiographic image. (author)

  7. Calibration and qualification of equipment in the pharmaceutical industry: emphasis on radiopharmaceuticals production

    International Nuclear Information System (INIS)

    Melero, Laura T.U.H.; Silva, Katia S. da S.; Zanette, Camila; Araujo, Elaine B. de; Mengatti, Jair

    2011-01-01

    The calibration and qualification of equipment are listed items in RDC number 17 of 2010 which refers about the Good Manufacturing Practice (GMP) of medicaments and RDC number 63 of 2009 which refers about GMP of Radiopharmaceuticals. Both are essential requirements since they are involved in process control to attend the regulatory criteria and are a key part of the validation process. The aim of this work is presenting the importance of calibration and qualification, and the routine use of equipment and facilities in industrial scale production of radiopharmaceuticals in the IPEN/CNEN. The radiopharmacy of IPEN is a pharmaceutical industry that produces radiopharmaceuticals for diagnosis and therapy. It was the pioneer institute in production of radioisotopes and radiopharmaceuticals in Brazil. Currently, 38 products are distributed to the nuclear medicine centers, including primary radioisotopes, labeled molecules and lyophilized reagents for labeling with technetium-99m. To fulfill the GMP requirements for quality assurance of products, several factors must be considered including infrastructure, equipment and raw materials beyond, obviously, the whole production process should be controlled until the release of the final product. Therefore, the calibration and verification of equipment, instruments and other appliances used in the production and quality control should be performed. A program of calibration, qualification and requalification of equipment used in production and quality control of radiopharmaceuticals is necessary for the validation of production processes and analytical methods, and should be established for quality assurance of produced radiopharmaceuticals. (author)

  8. Calibration and qualification of equipment in the pharmaceutical industry: emphasis on radiopharmaceuticals production

    Energy Technology Data Exchange (ETDEWEB)

    Melero, Laura T.U.H.; Silva, Katia S. da S.; Zanette, Camila; Araujo, Elaine B. de; Mengatti, Jair [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The calibration and qualification of equipment are listed items in RDC number 17 of 2010 which refers about the Good Manufacturing Practice (GMP) of medicaments and RDC number 63 of 2009 which refers about GMP of Radiopharmaceuticals. Both are essential requirements since they are involved in process control to attend the regulatory criteria and are a key part of the validation process. The aim of this work is presenting the importance of calibration and qualification, and the routine use of equipment and facilities in industrial scale production of radiopharmaceuticals in the IPEN/CNEN. The radiopharmacy of IPEN is a pharmaceutical industry that produces radiopharmaceuticals for diagnosis and therapy. It was the pioneer institute in production of radioisotopes and radiopharmaceuticals in Brazil. Currently, 38 products are distributed to the nuclear medicine centers, including primary radioisotopes, labeled molecules and lyophilized reagents for labeling with technetium-99m. To fulfill the GMP requirements for quality assurance of products, several factors must be considered including infrastructure, equipment and raw materials beyond, obviously, the whole production process should be controlled until the release of the final product. Therefore, the calibration and verification of equipment, instruments and other appliances used in the production and quality control should be performed. A program of calibration, qualification and requalification of equipment used in production and quality control of radiopharmaceuticals is necessary for the validation of production processes and analytical methods, and should be established for quality assurance of produced radiopharmaceuticals. (author)

  9. Review of foreign equipment for powered support control

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, W; Sobczyk, J

    1986-10-01

    A new generation of control systems are comparatively evaluated developed by Dowty, Hemscheidt and Thyssen-Siemens for powered supports and shield supports. Types of functions controlled by each system are discussed: support advancing (lowering support canopy, advancing, increasing pressure), control of support position, advancing chain conveyor. The following control systems are described: fully automatic control, remote control from a gate road, manual control from an adjacent support unit. Types of electronic equipment used in the control systems are described: microcomputers (8-bit CMOS device), 8-bit microcomputers, transmission systems, measuring instruments. Advantages of control systems developed and manufactured by the 3 companies are comparatively evaluated.

  10. Quality control of calibration system for area monitors at National Laboratory of Metrology from Ionizing Radiations (LNMRI)

    International Nuclear Information System (INIS)

    Ramos, M.M.O.; Freitas, L.C. de

    1992-01-01

    The quality control of equipment used in calibration from the National Laboratory of Metrology on Ionizing Radiations is presented, with results of standard measure systems and irradiation system. Tables and graphics with the quality of systems are also shown. (C.G.C.)

  11. Unsolved problems in applying U.S. regulatory guides to control system equipment

    International Nuclear Information System (INIS)

    Stade, R.E.

    1978-01-01

    Two current problems encountered when designing control systems to the United States Regulatory Guide requirements are discussed. They are: 1) Level of surge voltages that should be specified when procuring solid state control and instrumentation systems and equipment. 2) The approach to be used qualifying equipment that must meet the aging requirements. (author)

  12. X-ray quality control using TLD-100

    International Nuclear Information System (INIS)

    Rojas S, D. A.; Garcia V, E.; Azorin N, J.; Gaona, E.

    2017-10-01

    The use of thermoluminescent dosimeters in the area of medical physics and especially in radiology is of great importance to guarantee the quality of a given study, for this reason the need to verify by means of measurements for quality control in X-rays using thermoluminescent dosimeters of LiF:Mg,Ti was raised. For this, measurements of air Kerma, beam efficiency (reproducibility and linearity) and determination of the hemi-reductive layer were carried out, where previously the dosimeters were used, the graphs of the linear equation were used to obtain the absorbed dose of each dosimeter and thus the results of the absorbed dose calculated analytically against the value estimated by an electronic dosimeter were compared; it was found that the values of the absorbed dose are quantities similar to those stipulated by the electronic dosimeter. These measurements made it possible to verify the quality of the equipment that was used in the comparison. (Author)

  13. Interlaboratory comparison and accreditation in quality control testing of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Kepler, K.; Vladimirov, A.; Servomaa, A.

    2005-01-01

    The Univ. of Tartu provides a quality control service to the majority of diagnostic X-ray departments in Estonia. Its methodology has been adopted from the IEC and other relevant standards. Recently the Testing Centre of the Univ. of Tartu was accredited on this methodology by ISO/IEC 17025. Besides the implementation of the quality management system, participation in interlaboratory comparison (ILC) was one of the prerequisites for the accreditation. Tests for estimating reproducibility of tube voltage and dose rate, accuracy of the voltage and accuracy of exposure time were carried out on a diagnostic X-ray unit in the Radiation and Nuclear Safety Authority in Helsinki. The measurement performance was judged by calculating deviation En normalised with respect to the stated uncertainties. En values for all tests were less than unity and by the common ILC criteria the testing performance could be considered as acceptable. (authors)

  14. Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy

    International Nuclear Information System (INIS)

    Lin, Pei-Jan Paul

    2009-01-01

    New generation of fluoroscopic imaging systems is equipped with spectral shaping filters complemented with sophisticated automatic dose rate and image quality control logic called ''fluoroscopy curve'' or ''trajectory''. Such fluoroscopy curves were implemented first on cardiovascular angiographic imaging systems and are now available on conventional fluoroscopy equipment. This study aims to investigate the control logic operations under the fluoroscopy mode and acquisition mode (equivalent to the legacy spot filming) of a conventional fluoroscopy system typically installed for upper-lower gastrointestinal examinations, interventional endoscopy laboratories, gastrointestinal laboratory, and pain clinics.

  15. Application of QC_DR software for acceptance testing and routine quality control of direct digital radiography systems: initial experiences using the Italian Association of Physicist in Medicine quality control protocol.

    Science.gov (United States)

    Nitrosi, Andrea; Bertolini, Marco; Borasi, Giovanni; Botti, Andrea; Barani, Adriana; Rivetti, Stefano; Pierotti, Luisa

    2009-12-01

    Ideally, medical x-ray imaging systems should be designed to deliver maximum image quality at an acceptable radiation risk to the patient. Quality assurance procedures are employed to ensure that these standards are maintained. A quality control protocol for direct digital radiography (DDR) systems is described and discussed. Software to automatically process and analyze the required images was developed. In this paper, the initial results obtained on equipment of different DDR manufacturers were reported. The protocol was developed to highlight even small discrepancies in standard operating performance.

  16. Measurement and control system for ITER remote maintenance equipment

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Kiyoshi; Kakudate, Satoshi; Takeda, Nobukazu; Takiguchi, Yuji; Akou, Kentaro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-04-01

    ITER in-vessel components such as blankets and divertors are categorized as scheduled maintenance components because they are subjected to severe plasma heat and particle loads. Blanket maintenance requires remote handling equipment and tools able to handle Heavy payloads of about 4 tons within a 2 mm precision tolerance. Divertor maintenance requires remote replacement of 60 cassettes with a dead weight of about 25 tons each. In the ITER R and D program, full-scale remote handling equipment for blanket and divertor maintenance has been designed and assembled for demonstration tests. This paper reviews the measurement and control system developed for full-scale remote handling equipment, the Japan Home Team contribution. (author)

  17. Measurement and control system for ITER remote maintenance equipment

    International Nuclear Information System (INIS)

    Oka, Kiyoshi; Kakudate, Satoshi; Takeda, Nobukazu; Takiguchi, Yuji; Akou, Kentaro

    1998-01-01

    ITER in-vessel components such as blankets and divertors are categorized as scheduled maintenance components because they are subjected to severe plasma heat and particle loads. Blanket maintenance requires remote handling equipment and tools able to handle Heavy payloads of about 4 tons within a 2 mm precision tolerance. Divertor maintenance requires remote replacement of 60 cassettes with a dead weight of about 25 tons each. In the ITER R and D program, full-scale remote handling equipment for blanket and divertor maintenance has been designed and assembled for demonstration tests. This paper reviews the measurement and control system developed for full-scale remote handling equipment, the Japan Home Team contribution. (author)

  18. COMP report: CPQR technical quality control guidelines for low-dose-rate permanent seed brachytherapy.

    Science.gov (United States)

    Beaulieu, Luc; Radford, Dee-Ann; Eduardo Villarreal-Barajas, J

    2018-03-14

    The Canadian Organization of Medical Physicists (COMP), in close partnership with the Canadian Partnership for Quality Radiotherapy (CPQR) has developed a series of Technical Quality Control (TQC) guidelines for radiation treatment equipment. These guidelines outline the performance objectives that equipment should meet in order to ensure an acceptable level of radiation treatment quality. The TQC guidelines have been rigorously reviewed and field tested in a variety of Canadian radiation treatment facilities. The development process enables rapid review and update to keep the guidelines current with changes in technology. This article contains detailed performance objectives and safety criteria for low-dose-rate (LDR) permanent seed brachytherapy. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  19. Quality Management of CERN Vacuum Controls

    CERN Document Server

    Antoniotti, F; Fortescue-Beck, E; Gama, J; Gomes, P; Le Roux, P; Pereira, H; Pigny, G

    2014-01-01

    The vacuum controls Section (TE-VSC-ICM) is in charge of the monitoring, maintenance and consolidation of the control systems of all accelerators and detectors in CERN; this represents 6 000 instruments distributed along 128 km of vacuum chambers, often of heterogeneous architectures and of diverse technical generations. In order to improve the efficiency of the services provided by ICM, to vacuum experts and to accelerator operators, a Quality Management Plan is being put into place. The first step was the standardization of the naming convention across different accelerators. The traceability of problems, requests, repairs, and other actions, has also been put into place (VTL). This was combined with the effort to identify each individual device by a coded label, and register it in a central database (MTF). Occurring in parallel, was the gathering of old documents and the centralization of information concerning architectures, procedures, equipment and settings (EDMS). To describe the topology of control c...

  20. Image guided radiotherapy. Quality control of X ray equipment. S.F.P.M. report nr 29

    International Nuclear Information System (INIS)

    Delpon, Gregory; Aubignac, Leone; Bramoulle, Celine; Boutry, Christine; Guerin, Lucie; Lafay, Frederic; Benoit, David; Garcia, Robin; Jaegle, Enric; Vieillevigne, Laure; Dedieu, Veronique; Ferrrer, Ludovic; Guillhem, Marie-Therese; Lacaze, Brigitte; Mazurier, Jocelyne; Simon, Luc

    2014-01-01

    This report presents different X ray imagery systems used for positioning support in external radiation therapy, and installed in treatment rooms. If portal imagery systems and rail-mounted tomodensitometry systems are not addressed in this document, the authors distinguish and describe various embedded systems in which devices are directly mounted on the treatment apparatus (X-Ray Volume Imaging by Elekta, On Board Imager by Varian), peripheral systems which are independent from the machine (Cyberknife by Accuray and Exatrac by BrainLab), MVCT or Mega Voltage Computed Tomography systems (Tomotherapy by Accuray), and MVCBCT or Megavoltage Cone Beam Computed Tomography systems (Artiste by Siemens). After a brief presentation of these systems, the author present various aspects of quality controls (list, periodicity, test tolerance, tested objects), and then more precisely describe the above-mentioned systems. For each of them, the following aspects are addressed: generator, geometry, image quality, dose, environment and safety, gating module, quality controls

  1. Quality control in diagnostic radiology. Historical development and present status in Europe

    International Nuclear Information System (INIS)

    Michael Moores, B.

    2007-01-01

    Complete test of publication follows. Quality control is now an accepted activity within the overall radiation protection framework for diagnostic radiology. Indeed it is now a legal requirement within Member States specified in EC Directives that establish the basic requirements for radiation protection in medicine. This was not always the case and its historical development can be considered in three parts: 1) The development of test procedures and standardisation of practices; 2) Harmonisation of initiatives and the creation of a European dimension in such practices; 3) Its role and function in a changing and evolving technological environment - current status and future needs. The development of tests methods for diagnostic X-ray equipment was initially intimately related to the development of a scientific basis for the X-ray imaging process. Knowledge of the physical basis for image production in film-screen and fluoroscopic processes required the definition and specification and measurement of particular parameters within the image forming chain. The development of test methods and the necessary measuring equipment involved ongoing research and development by physical scientists throughout Europe and North America. However, the many different approaches employed meant that results of measurements could not always be compared. However, once acceptable test methods and equipment had been developed it was possible to standardise practices through the development of test protocols. In 1980 a foundation for collective European actions was established through the EC radiation protection research and development programme. This helped to establish a European wide forum for actions in the field of medical radiation protection including quality control. These initiatives were driven by EC Directives, which were concerned with protection of the worker, general public and patients from medical practices that utilised ionising radiation. Multi national research

  2. Reduction of patient doses in X-ray diagnosis using quality control tests on image and equipment

    International Nuclear Information System (INIS)

    Milu, C.; Tomulescu, V.; Sorescu, Anca; Vladareanu, M.; Olteanu, B.; Enachescu, B.; Zaharia, N.; Lesaru, M.

    1997-01-01

    In the frame of a research program under the contract with the International Atomic Energy Agency (IAEA), several patient dose measurements were performed using thermoluminescent dosemeters (TLDs) before and after application of Quality Control tests and patient dose reduction methods. The paper evidenced the practical influence factors (like the need of use of high voltage technique) and possibilities for dose reduction keeping the image quality. (authors)

  3. A compliance testing program for diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Hutchinson, D.E.; Cobb, B.J.; Jacob, C.S.

    1999-01-01

    Compliance testing is nominally that part of a quality assurance program dealing with those aspects of X-ray equipment performance that are subject to radiation control legislation. Quality assurance programs for medical X-ray equipment should be an integral part of the quality culture in health care. However while major hospitals and individual medical centers may implement such programs with some diligence, much X-ray equipment can remain unappraised unless there is a comprehensive regulatory inspection program or some form of compulsion on the equipment owner to implement a testing program. Since the late 1950s all X-ray equipment in the State of Western Australia has been inspected by authorized officers acting on behalf of the Radiological Council, the regulatory authority responsible for administration of the State's Radiation Safety Act. However, economic constraints, coupled with increasing X-ray equipment numbers and a geographically large State have significantly affected the inspection rate. Data available from inspections demonstrate that regular compliance and performance checks are essential in order to ensure proper performance and to minimize unnecessary patient and operator dose. To ensure that diagnostic X-ray equipment complies with accepted standards and performance criteria, the regulatory authority introduced a compulsory compliance testing program for all medical, dental and chiropractic diagnostic X-ray equipment effective from 1 January 1997

  4. Remote handling equipment for CANDU retubing

    International Nuclear Information System (INIS)

    Crawford, G.S.; Lowe, H.

    1993-01-01

    Numet Engineering Ltd. has designed and supplied remote handling equipment for Ontario Hydro's retubing operation of its CANDU reactors at the Bruce Nuclear Generating Station. This equipment consists of ''Retubing Tool Carriers'' an'' Worktables'' which operate remotely or manually at the reactor face. Together they function to transport tooling to and from the reactor face, to position and support tooling during retubing operations, and to deliver and retrieve fuel channels and channel components. This paper presents the fundamentals of the process and discusses the equipment supplied in terms of its design, manufacturing, components and controls, to meet the functional and quality requirements of Ontario Hydro's retubing process. (author)

  5. Association between product quality control and process quality control of bulk milk

    NARCIS (Netherlands)

    Velthuis, A.; Asseldonk, van M.A.P.M.

    2010-01-01

    Assessment of dairy-milk quality is based on product quality control (testing bulk-milk samples) and process quality control (auditing dairy farms). It is unknown whether process control improves product quality. To quantify possible association between product control and process control a

  6. Management of radiodiagnostic equipment: Implementation of self-maintenance project of the conventional x-ray equipment of Hospital Universitario Clementino Fraga Filho - HUCFF-UFRJ

    International Nuclear Information System (INIS)

    Couto, N.F. do; Azevedo, A.C.P.; Koch, H.A.

    2001-01-01

    The project aims the implantation of a management program, for the maintenance of the conventional X-ray equipment at HUCFF. It has been implemented through the training of the electronic technicians who work at the Hospital. Essential courses were organized such as: Basics of Radioprotection, Radiographs Techniques, and Maintenance of equipment of X-Rays. Equipment: a library with the schemes of the equipment is being assembled in collaboration with UNICAMP. In order to manage the process, a software was created using the tools of the total quality for control of the maintenance. Preliminary tests: the equipment and their working conditions were evaluated, as well as the level of the employees' satisfaction with their use. The creation of a new routine for maintenance seeks to assist the demands of the new legislation in Brazil 5, and also reduce the costs to improve the quality of the images in the Radiodiagnostic Service. (author)

  7. Improved control rod drive handling equipment for BWRs [boiling-water reactors]: Final report

    International Nuclear Information System (INIS)

    Turner, A.P.L.; Gorman, J.A.

    1987-08-01

    Improved equipment for removing and replacing control rod drives (CRDs) in BWR plants has been designed, built and tested. Control rod drives must be removed from the reactor periodically for servicing. Removal and replacement of CRDs using equipment originally supplied with the plant has long been recognized as one of the more difficult and highest radiation exposure maintenance operations that must be performed at BWR plants. The improved equipment was used for the first time at Quad Cities, Unit 2, during a Fall 1986 outage. The trial of the equipment was highly successful, and it was shown that the new equipment significantly improves CRD handling operations. The new equipment significantly simplifies the sequence of operations required to lower a CRD from its housing, upend it to a horizontal orientation, and transport it out of the reactor containment. All operations of the new equipment are performed from the undervessel equipment handling platform, thus, eliminating the requirement for a person to work on the lower level of the undervessel gallery which is often highly contaminated. Typically, one less person is required to operate the equipment than were used with the older equipment. The new equipment incorporates a number of redundant and fail safe features that improve operations and reduce the chances for accidents

  8. Quality Control Applications

    CERN Document Server

    Chorafas, Dimitris N

    2013-01-01

    Quality control is a constant priority in electrical, mechanical, aeronautical, and nuclear engineering – as well as in the vast domain of electronics, from home appliances to computers and telecommunications. Quality Control Applications provides guidance and valuable insight into quality control policies; their methods, their implementation, constant observation and associated technical audits. What has previously been a mostly mathematical topic is translated here for engineers concerned with the practical implementation of quality control. Once the fundamentals of quality control are established, Quality Control Applications goes on to develop this knowledge and explain how to apply it in the most effective way. Techniques are described and supported using relevant, real-life, case studies to provide detail and clarity for those without a mathematical background. Among the many practical examples, two case studies dramatize the importance of quality assurance: A shot-by-shot analysis of the errors made ...

  9. Quality control of mammographic systems

    International Nuclear Information System (INIS)

    Espana Lopez, M. L.

    2001-01-01

    High quality in mammography is a difficult objective to achieve, that is the reason for what efforts are made in order to improve equipment, to offer good combinations screen-film, and professional staff dedicated to this technique [es

  10. Reliability of nondestructive testing of metal strength properties for power equipment

    International Nuclear Information System (INIS)

    Bugaj, N.V.; Lebedev, A.A.; Sharko, A.V.

    1985-01-01

    Ultrasonic control which is a constituent part of a complex control system which includes specimen-free (by hardness) tests, random breaking tests and acoustic measurements is stUdied for its reliability with respect to strength properties of power-equipment metal. Quantitative and alternative criteria are developed to estimate quality of elements for power-equipment according to results of metal strength properties. Acoustic control results are presented for ultimate strength in 12Kh1MF-steel

  11. Analyze for the Quality Control of General X-ray Systems in Capital region

    International Nuclear Information System (INIS)

    Kang, Byung Sam; Lee, Kang Min; Shin, Woo Yong; Park, Soon Chul; Choi, Hak Dong; Cho, Yong Kwon

    2012-01-01

    Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.

  12. Development of Tandem ionization chambers for use in quality control programs in radiotherapy and diagnostic radiology

    International Nuclear Information System (INIS)

    Costa, Alessandro Martins da

    2003-01-01

    A quality control program of X-ray equipment used in diagnostic radiology and radiotherapy requires the check of the beam qualities constancy in terms of the half-value layers. In this work, two special double-faced parallel-plate ionization chambers were developed with inner electrodes of different materials, in tandem system. The different energy response of the two faces of each chamber allowed the development of tandem systems useful for the check of beam qualities constancy. The main application of these ionization chambers will be in quality control programs of diagnostic and therapeutic X-ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the tandem chambers may also be utilized for measurements of air kerma values (and air kerma rates) in kilo voltage X-radiation fields used for diagnostic and therapeutic procedures. The chambers were studied in relation to their operational characteristics, and they were calibrated in X-ray beams in accordance to international recommendations. They presented a very good level of performance. In this developed system no absorbers or special set-ups are necessary. A methodology of use of the chambers in the quality control of diagnostic and therapeutic X-ray systems was established, with the elaboration of the respective procedures. (author)

  13. Development of high quality cereal drying and storage equipment, 2: Microorganism control using ultraviolet irradiation and TiO2

    International Nuclear Information System (INIS)

    Kubota, K.; Hidaka, Y.

    2004-01-01

    Abstract In this paper, in order to obtain the condition of practical ultraviolet sterilization, we made a recirculating grain sterilization equipment using ultraviolet irradiation. We investigated the ultraviolet sterilization of microorganism that adhere to the wheat surface. And we examined the quality of those wheat. Moreover, we investigated the sterilization using titanium dioxide attracted attention as a photocatalyst and ultraviolet irradiation. As a result of sterilization experiment, sterilization time required in order to obtain the sterilization rate of 90% was 6.3 hours for bacteria and 5.6 hours for fungi under condition of 97W/square m ultraviolet irradiance. In this experiment using ultraviolet irradiation and titanium dioxide, sterilization time required to obtain the sterilization rate of 90% was 4.8 hours for bacteria and 4.5 hours for fungi. We could shorten the sterilization time. In the quality examination, it was thought that there was little influence on quality by ultraviolet irradiation in this range from the germination test and the amylograph examination. As a result of calculating ultraviolet radiant energy for 30 t of grain, it was estimated as 84 MJ

  14. Stability of two measuring systems used in quality control of mammography; Estabilidade de dois sistemas de medicao utilizados no controle de qualidade de mamografos

    Energy Technology Data Exchange (ETDEWEB)

    Barreira, Jacqueline Sales; Vivolo, Vitor, E-mail: jacsales@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2014-07-01

    The use of X-Rays for diagnosis is very important for medicine, including mammographic exam. A quality control program is necessary to control the radiation systems performance. The objective of this paper is evaluation of stability of measurement working system and measurement standard system, collecting meters of charge and dose using one source of Strontium 90 (Sr-90). The results of this test are very important to determine if the instruments are calibrated for use in quality control program for a mammography equipment. (author)

  15. Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Pei-Jan Paul [Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2009-05-15

    New generation of fluoroscopic imaging systems is equipped with spectral shaping filters complemented with sophisticated automatic dose rate and image quality control logic called ''fluoroscopy curve'' or ''trajectory''. Such fluoroscopy curves were implemented first on cardiovascular angiographic imaging systems and are now available on conventional fluoroscopy equipment. This study aims to investigate the control logic operations under the fluoroscopy mode and acquisition mode (equivalent to the legacy spot filming) of a conventional fluoroscopy system typically installed for upper-lower gastrointestinal examinations, interventional endoscopy laboratories, gastrointestinal laboratory, and pain clinics.

  16. Design of equipment management information system for nuclear power plant

    International Nuclear Information System (INIS)

    Wang Chengyuan

    1996-01-01

    The author describes the ideas and practical method for need analysis, system function dividing, code design, program design and network disposition of equipment purchase management system of nuclear power plant during building, from the view of engineering investment control, schedule control and quality control

  17. Patients Radiation Load Caused by Digitalised X-Ray Equipment

    International Nuclear Information System (INIS)

    Nikodemova, D.; Prikazska, M.; Horvathova, M.

    2001-01-01

    Full text: The radiation load of population all over the world from medical examinations clearly demonstrate the importance of implementation of quality assurance and quality control programmes into the activities of radiological departments. The basic aim of quality assurance programme is to ensure that the radiation dose is kept as low as reasonably practicable consistent with adequate image quality. As many other fields, the rapid development of techniques brought change-over from the conventional analogue technique to the digital technique. In this connection conventional X-ray film is being abandoned and images are being viewed on either laser film or monitor. The main advantages of using digital equipment lay in improved image quality and diagnostic accuracy through digital image processing, reduction in patient exposure, cost reduction by reduction film usage, more efficient storage and retrieval of radiographic images through picture archiving. Several studies that have been conducted for comparison of various diagnostic examinations performed on digital and analogue X-ray equipment have shown that in barium meal examinations, there is potential for dose saving in the digital image intensifier technique. The aim of this study was to compare measured values of dose-area product for colon investigations using different X-ray equipment types, on digital and one analogue. Our material consisted of 60 randomly selected patients, 24 of them were examined with digital equipment and 36 patients with the analogue equipment. (author)

  18. Inquiry about the uses of special equipment (CT equipment, angiography systems, mammography devices, screens)

    International Nuclear Information System (INIS)

    Schwager, P.; Stieve, F.E.

    1986-01-01

    There are at least 1100 special devices in medical establishment in Bavaria which require special inspection and surveillance with regard to quality of equipment and radiation protection. In addition, there are at least 53 tomographs available for operation, and at least 120 installed X-ray screens. These devices need special approval testing and quality control services as they contribute a very significant amount of the medically indicated radiation exposure of the population. Appropriate measures are explained that can be applied in order to reduce the medical radiation exposure to an optimum. (orig.) [de

  19. Quality control in breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Jakubiak, R.R.; Messias, P.C.; Santos, M.F., E-mail: requi@utfpr.edu.br [Universidade Tecnologia Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Fisica; Urban, L.A.B.D., E-mail: lineiurban@hotmail.com [Diagnostico Avancado por Imagem, Curitiba, PR (Brazil)

    2015-07-01

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  20. Quality control in breast tomosynthesis

    International Nuclear Information System (INIS)

    Jakubiak, R.R.; Messias, P.C.; Santos, M.F.

    2015-01-01

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  1. Quality control in breast tomosynthesis

    International Nuclear Information System (INIS)

    Jakubiak, Rosangela Requi; Messias, Pricila Cordeiro; Santos, Marilia Fernanda; Urban, Linei Augusta B.D.

    2014-01-01

    In Brazil breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Breast Digital Tomosynthesis (BDT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared to the mammography. This study presents results of Contrast Ratio Noise tests (CRN) and quality image on a Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CRN was determined with plates Polymethylmethacrylate (PMMA) of 20 to 70 mm thickness and an aluminum plate of 10 mm 2 and 0.2 mm thickness. Image quality was assessed with the ACR Breast Simulator. In assessment of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Were visualized 4.5 fibers and 4 mass in both modes. In 2D mode groups have been identified 3.5 microcalcifications, and 3D were 3 groups. The Mean Glandular Dose for the simulator in 2D mode was 1.17 mGy and 2.35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CRN values, ensuring image quality and dose compatible in 2D and 3D processes

  2. If You Don't Know, Ask! Using Expert Knowledge to Determine What Content Is Needed in an Undergraduate Food Quality Management and Control Course

    Science.gov (United States)

    Joyner, Helen S.; Stevenson, Clinton D.

    2017-01-01

    Quality management and quality control of food products are critical to producing food that is safe to consume and has consistent quality and sensory attributes. The extent to which undergraduate students are equipped with competencies in quality management/control, in theory, has a direct connection with their career potential to ensure food…

  3. Development of special ionization chambers for a quality control program in mammography

    International Nuclear Information System (INIS)

    Silva, Jonas Oliveira da

    2013-01-01

    Mammography is an imaging method that uses X-rays. The use of ionization chambers in mammography quality control programs presents an essential role which is to verify whether the parameters of the patient exposure are correct. However, the commercial ionization chambers for dosimetry in mammography represent a high cost for small and medium size clinics that wish to have this equipment or for professionals that work with quality control programs. The innovative feature of this work was to develop ionization chambers for this purpose. In this work ionization chambers for X radiation beams in the mammography energy range were designed, constructed and characterized. The ionization chambers were tested in standard X radiation beams at the LCI/IPEN. The main characterization tests performed with the ionization chambers were: saturation curve, linearity of response, angular and energy dependence. The response stability tests of the ionization chambers were also conducted at the LCI, presenting results within 2.0 % for long-term stability. The results of the remaining tests are in accordance with international standards. These ionization chambers were also submitted to quality control tests of mammography equipment: linearity of the air kerma rates, determination of half-value layers and mean glandular doses. The results for air kerma rate linearity were less than 10 %, as recommended in international standards. The mean glandular dose obtained with the developed chambers presented values comparable to those of commercial ionization chambers tested, with an estimated variation within international standards. (author)

  4. Intercomparison of quality control procedures in radiotherapy in the Netherlands

    International Nuclear Information System (INIS)

    Kleffens, H.J. van; Meijer, G.J.; Mijnheer, B.J.

    1997-01-01

    A grant was received from the Dutch government to accomplish the development and implementation of guidelines for quality control (QC) of radiotherapy equipment in The Netherlands. QC of electron accelerators, simulators, CT scanners, mould room equipment, dosimetry equipment and treatment planning systems will be considered in this project. The project started in September 1994 with an investigation of QC of medical electron accelerators as performed in all 21 radiotherapy institutions in The Netherlands. An extensive questionnaire on QC procedures of electron accelerators was sent to all centres with items related to safety systems, mechanical aspects, radiation leakage, beam data and dosimetry equipment (in total about 60 questions). From the answers the following conclusions can be drawn: There is a large variation in time spent on QC; This QC time strongly depends on the complexity of the linear accelerator; There is a large variation in frequency and tolerance levels of the various tests; The way QC of an item is performed differs considerably (extensive-comprehensive). From these data recommendations specific for the situation in The Netherlands are being prepared and compared with other existing national and international reports. Similar procedures are underway for CT scanners and simulators while for the other equipment minimum guidelines still have to be developed. (author)

  5. Problematic of the implantation of quality control in the radiodiagnostic service of a hospital with more than 5000 beds with a urgency service

    International Nuclear Information System (INIS)

    Castell, A.; Lizuain, M.C.; Cinos, C.; Linero, D.

    1992-01-01

    The quality control of the x-ray equipment is not normal in the Hospitals. This technique has very difficulties. In this report we show the methodology in order to implant the quality control in radiodiagnostic service : data acquisition and format of communication

  6. The process control and management on equipment qualification of nuclear power plant

    International Nuclear Information System (INIS)

    Liu Dong; Wang Hongyin; Zhang Yong

    2013-01-01

    The equipment qualification (EQ) to the safety class equipment is an important safety measure for the nuclear power plants (NPP), and also reflects the nuclear safety culture. Along with the continuous constructions of NPP in China, it has become an important issue for NPP engineering company and equipment suppliers how to effectively establish standard EQ process control and management, and provide sufficient technical arrangements to maintain this EQ management system. This paper summarizes three process of EQ including Design Input, EQ Establishment and EQ Maintenance, proposes the measures and key points for EQ process control and management in phase of NPP construction, and introduces the documents management during the whole process of EQ. (authors)

  7. Dynamic monitoring equipment for earthworks and sub grades; Euipos de auscultacion dinamica para obras de tierra

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez de Sotomayor, R.

    2013-06-01

    This paper take into account some dynamic auscultation equipment s that currently are available in Spain for compaction quality control on earthworks and sub grades. Closed to the equipment description, a deformation modulus calculus approximation has been developed for each of them. A standards checking has been made from national and European point of view. some important research works that have been developed in our country about dynamic monitoring equipment s for quality control in earthworks has been mentioned. In addition to this, some variables are analyzed which have an influence on deformation modulus calculi and a possibility for comparing the equipment modulus calculated with a reference laboratory test has been offered. (Author) 18 refs.

  8. Pengukuran Overall Equipment Effectiveness (Oee) Dengan Labview 8.5 Sebagai Pengendali Maintenance

    OpenAIRE

    Syarief, Syafrizal

    2015-01-01

    Total Productive Maintenance (TPM) is a philosophy that aims to maximize the effectiveness of the facilities used in industry, it is applied to analyze problems that occur on any equipment and machinery with a method of calculation of Overall Equipment Effectiveness (OEE) of product quality. Value is determined by OEE Availability, Performance and Yield / Quality. LabVIEW (Laboratory Virtual Instrument Engineering Workbench) software is dedicated to the activities of the interface and control...

  9. Quality control tools applied to a PV microgrid in Ecuador

    Energy Technology Data Exchange (ETDEWEB)

    Camino-Villacorta, M.; Egido-Aguilera, M.A. [Ciudad Univ., Madrid (Spain). Inst. de Energia Solar - UPM; Gamez, J.; Arranz-Piera, P. [Trama Tecnoambiental (TTA), Barcelona (Spain)

    2010-07-01

    The Instituto de Energia Solar has been dealing with quality control issues for rural electrification for many years. In the framework of project DOSBE (Development of Electricity Service Operators for Poverty Alleviation in Ecuador and Peru), a technical toolkit has been developed to implement adapted integral quality control procedures for photovoltaic systems (covering all components and equipment, installation and servicing), applicable at a local and regional scale, with the overall aim of increasing the confidence in photovoltaic systems. This toolkit was applied in the evaluation of an existing microgrid in Ecuador, which is described in this paper. The toolkit and the detailed results of its application are presented in a published document which is being widely distributed among the stakeholders of rural electrification in Ecuador and Peru. It can be downloaded from the web page of the DOSBE project: www.dosbe.org (orig.)

  10. Current trends in small vocabulary speech recognition for equipment control

    Science.gov (United States)

    Doukas, Nikolaos; Bardis, Nikolaos G.

    2017-09-01

    Speech recognition systems allow human - machine communication to acquire an intuitive nature that approaches the simplicity of inter - human communication. Small vocabulary speech recognition is a subset of the overall speech recognition problem, where only a small number of words need to be recognized. Speaker independent small vocabulary recognition can find significant applications in field equipment used by military personnel. Such equipment may typically be controlled by a small number of commands that need to be given quickly and accurately, under conditions where delicate manual operations are difficult to achieve. This type of application could hence significantly benefit by the use of robust voice operated control components, as they would facilitate the interaction with their users and render it much more reliable in times of crisis. This paper presents current challenges involved in attaining efficient and robust small vocabulary speech recognition. These challenges concern feature selection, classification techniques, speaker diversity and noise effects. A state machine approach is presented that facilitates the voice guidance of different equipment in a variety of situations.

  11. Development and implementation of a low-cost phantom for quality control in cone beam computed tomography

    International Nuclear Information System (INIS)

    Batista, W. O.; Navarro, M. V. T.; Maia, A. F.

    2013-01-01

    A phantom for quality control in cone beam computed tomography (CBCT) scanners was designed and constructed, and a methodology for testing was developed. The phantom had a polymethyl methacrylate structure filled with water and plastic objects that allowed the assessment of parameters related to quality control. The phantom allowed the evaluation of essential parameters in CBCT as well as the evaluation of linear and angular dimensions. The plastics used in the phantom were chosen so that their density and linear attenuation coefficient were similar to those of human facial structures. Three types of CBCT equipment, with two different technological concepts, were evaluated. The results of the assessment of the accuracy of linear and angular dimensions agreed with the existing standards. However, other parameters such as computed tomography number accuracy, uniformity and high-contrast detail did not meet the tolerances established in current regulations or the manufacturer's specifications. The results demonstrate the importance of establishing specific protocols and phantoms, which meet the specificities of CBCT. The practicality of implementation, the quality control test results for the proposed phantom and the consistency of the results using different equipment demonstrate its adequacy. (authors)

  12. Development of a plug in for image j for the quality control of a scanner

    International Nuclear Information System (INIS)

    Otal Palacin, A.; Fuentemilla Urio, N.; Olasolo Alonso, J.; Martin Albina, M. L.; Miquelez Alonso, S.; Lozares Cordero, S.; Pellejero, S.; Maneru Camara, F.; Rubio Arroniz, A.; Soto Prados, P.

    2013-01-01

    The increase in the quality of radiology equipment requirements necessitates that give us tools efficient that they simplify the more possible tasks of analysis of the data obtained in the quality controls. We can choose by solutions based on commercial software or otherwise try to develop our own to measure of our needs. For this reason we have developed a plug-in for the ImageJ program that automates the work of analysis of image quality in the Navarro health service scanners. (Author)

  13. [Technological innovations in radiation oncology require specific quality controls].

    Science.gov (United States)

    Lenaerts, E; Mathot, M

    2014-01-01

    During the last decade, the field of radiotherapy has benefited from major technological innovations and continuously improving treatment efficacy, comfort and safety of patients. This mainly concerns the imaging techniques that allow 4D CT scan recording the respiratory phases, on-board imaging on linear accelerators that ensure perfect positioning of the patient for treatment and irradiation techniques that reduce very significantly the duration of treatment sessions without compromising quality of the treatment plan, including IMRT (Intensity Modulated Radiation Therapy) and VMAT (Volumetric Modulated Arc therapy). In this context of rapid technological change, it is the responsibility of medical physicists to regularly and precisely monitor the perfect functioning of new techniques to ensure patient safety. This requires the use of specific quality control equipment best suited to these new techniques. We will briefly describe the measurement system Delta4 used to control individualized treatment plan for each patient treated with VMAT technology.

  14. Quality control and radioprotection in dental cone beam computed tomography - case study

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Ligiane C.N.; Ferreira, Nadya M.P.D., E-mail: lnadya@ime.eb.br [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    The radiological protection in medical and odontologic radiology follows The Order (Portaria) 453/98 of the Ministry of Health, which presents the minimum set of tests for the constancy X-ray equipment. These tests follow the procedures set forth in the Resolution no. 64, the National Agency for Sanitary Vigilance. This work aims to show a study on dental cone beam computed tomography (CBCT), evaluating the physical parameters that influence the performance and image quality and presenting the appropriate tests to this new system. The authors analyzed the tests specific for computed tomography (CT) of the Resolution no. 64, feasibility assessment of them and if their interpretations are compatible with CBCT. Once determined if testing is feasible, compare with those presented in the manual provided by the equipment manufacturer. The CT scanner used was the Mini-Cat Tomography Scanner Xoran Technologies of KAVO. In the study it was verified that four tests could be reproduced in CBCT: noise, accuracy and uniformity in the number of CT of water and spatial resolution. Considering experimental data, the methodology and tolerance of manufacturer for the first two tests were more appropriate. For the uniformity test of the CT number, we recommend using the phantom quality control. Three new tests were suggested to be made in the quality control of the Cone Beam: linearity, artifacts and alignment of the beam. (author)

  15. Quality control and radioprotection in dental cone beam computed tomography - case study

    International Nuclear Information System (INIS)

    Rodrigues, Ligiane C.N.; Ferreira, Nadya M.P.D.

    2011-01-01

    The radiological protection in medical and odontologic radiology follows The Order (Portaria) 453/98 of the Ministry of Health, which presents the minimum set of tests for the constancy X-ray equipment. These tests follow the procedures set forth in the Resolution no. 64, the National Agency for Sanitary Vigilance. This work aims to show a study on dental cone beam computed tomography (CBCT), evaluating the physical parameters that influence the performance and image quality and presenting the appropriate tests to this new system. The authors analyzed the tests specific for computed tomography (CT) of the Resolution no. 64, feasibility assessment of them and if their interpretations are compatible with CBCT. Once determined if testing is feasible, compare with those presented in the manual provided by the equipment manufacturer. The CT scanner used was the Mini-Cat Tomography Scanner Xoran Technologies of KAVO. In the study it was verified that four tests could be reproduced in CBCT: noise, accuracy and uniformity in the number of CT of water and spatial resolution. Considering experimental data, the methodology and tolerance of manufacturer for the first two tests were more appropriate. For the uniformity test of the CT number, we recommend using the phantom quality control. Three new tests were suggested to be made in the quality control of the Cone Beam: linearity, artifacts and alignment of the beam. (author)

  16. Quality control of radioactive waste products

    International Nuclear Information System (INIS)

    Martens, B.R.; Warnecke, E.; Odoj, R.

    1986-01-01

    The variety of incoming untreated wastes, treatment methods, waste forms and containers requires a great variety of controlling methods and principles to be applied both during waste treatment and on the final product. The paper describes product control schemes and methods, sampling systems and transportable testing equipment for waste drums, and equipment for waste cementation using in-drum stirring and subsequent fixation of solid wastes in the flowable product. (DG) [de

  17. Software for creating quality control database in diagnostic radiology

    International Nuclear Information System (INIS)

    Stoeva, M.; Spassov, G.; Tabakov, S.

    2000-01-01

    The paper describes a PC based program with database for quality control (QC). It keeps information about all surveyed equipment and measured parameters. The first function of the program is to extract information from old (existing) MS Excel spreadsheets with QC surveys. The second function is used for input of measurements which are automatically organized in MS Excel spreadsheets and built into the database. The spreadsheets are based on the protocols described in the EMERALD Training Scheme. In addition, the program can make statistics of all measured parameters, both in absolute term and in time

  18. Flaw detection of welded joints in NPP equipment assembly

    International Nuclear Information System (INIS)

    Kesler, N.A.; Polevik, V.A.; Orlov, N.S.

    1984-01-01

    State of the art and prospects of development of ultrasonic and radiography testing of welded joints for quality used in NPP equipment assembly are considered. Recommendations are given on reducing the labour content with the use of these methods. Specifications for the developed facilities intended for automation and mechanization of the described quality control methods are presented

  19. Quality Management, Quality Assurance and Quality Control in Blood Establishments

    OpenAIRE

    Bolbate, N

    2008-01-01

    Quality terms and the roots of the matter are analyzed according to European Committee’s recommendations. Essence of process and product quality control as well as essence of quality assurance is described. Quality system’s structure including quality control, quality assurance and management is justified in the article.

  20. Comprehensive framework for preventive maintenance priority of medical equipment.

    Science.gov (United States)

    Saleh, Neven; Balestra, Gabriella

    2015-08-01

    Throughout the medical equipment life cycle, preventive maintenance is considered one of the most important stages that should be managed properly. However, the need for better management and control by giving a reasonable prioritization for preventive maintenance becomes essential. The purpose of this study is to develop a comprehensive framework for preventive maintenance priority of medical equipment using Quality Function Deployment (QFD) and Fuzzy Logic (FL). The quality function deployment is proposed in order to identify the most important criteria that could impact preventive maintenance priority decision; meanwhile the role of the fuzzy logic is to generate a priority index of the list of equipment considering those criteria. The model validation was carried out on 140 pieces of medical equipment belonging to two hospitals. In application, we propose to classify the priority index into five classes. The results indicate that the strong correlation existence between risk-based criteria and preventive maintenance priority decision.

  1. Possible radiation dose reduction by using digital X-ray equipment

    International Nuclear Information System (INIS)

    Horvathova, M.; Nikodemova, D.; Prikazska, M.

    2001-01-01

    The radiation load of population all over the world from medical examinations clearly demonstrates the importance of the introduction of the quality assurance and quality control programmes into the activities of radiology departments. The basic aim of quality assurance program is to ensure that the radiation dose is kept as low as reasonably practicable while still providing an adequate image quality. As many other fields, the rapid development of techniques brought change-over from the conventional analogue technique to the digital technique. In this process, the conventional X-ray film is being abandoned and images are being viewed on either laser film or monitor. The main advantages of using digital equipment lay in improved image quality and diagnostic accuracy through digital image processing, reduction in patients exposure, cost reduction by reduction of the film usage, more efficient storage and retrieval of radiographic images through picture archiving. Several studies that have been conducted for comparison of various diagnostic examinations show , that there is potential for dose saving in the digital image intensifier technique. The aim of this study was to compare measured values of dose-area product for colon investigations using different X-ray equipment types, two digital and two analogue. Our material consisted of 169 randomly selected patients, 115 of them were examined with digital equipment and 54 patients with the analogue equipment. The obtained results have confirmed the dose reduction and increase of diagnostic accuracy when using the digital equipment, with the added benefit of a good image quality. (authors)

  2. Quality control in the commerce of irradiated foods

    International Nuclear Information System (INIS)

    Bustos R, M.E.

    2000-01-01

    In spite of an irradiated food is innocuous for health and that the irradiation process offers great advantages as conservation and hygiene method and it has been recognised by the Agriculture and Health International organizations and although the adequate equipment exists to make this treatment in the majority of countries, an international trade of irradiated foods has not been established and it is that it has to be required that the quality control of the treatment should be regulated by the corresponding authorities and it also should be harmonized with other countries for the commercial interchange. Owing to up to present an identification method of irradiated foods which is validated, the unique quality control for irradiated foods is realized in the irradiation plant, measuring the absorbed dose in products, using dosimetric systems justly calibrated and standardized to be used the adequate for the type of product and dose level which is wanted to be measured for foods mainly for quarantine treatment which is very important to determine that any part of the irradiation system has reached the minimum dose to obtain the technical effect which is desired and that it does not exceed the maximum dose for that the product quality not to be altered. (Author)

  3. Establishment of seed quality control programs Implantação de programas de controle de qualidade de sementes

    Directory of Open Access Journals (Sweden)

    S. M. Cicero

    1998-01-01

    Full Text Available An efficient quality control program should lead to the production of high quality seeds. Consequently, a series of technical and administrative procedures must be adopted in a way that does not compromise this objective. Considering that, in applied terms, external control becomes less important as internal control programs advance technologically, this work emphasizes the principle factors that should be considered in the implantation of a seed quality control program, such as: work groups, physical structure and procedures to initiate the program.Um programa de controle de qualidade deve proporcionar a produção de sementes de alta qualidade. Para que tal objetivo seja alcançado com sucesso, e necessário a adoção de uma serie de procedimentos técnicos e administrativos, sem os quais haverá comprometimento das metas a serem atingidas. Levando-se em conta que, em termos aplicados, o controle externo perde importância na medida que avançam tecnologicamente os programas de controle interno, o presente trabalho aborda os principais fatores que devem ser considerados na implantação de um programa de controle de qualidade de sementes, tais como: equipe de trabalho, estrutura física e procedimentos para iniciar o programa.

  4. Evaluation of the air quality in pig housing facilities equipped with a liquid-solid separation system

    International Nuclear Information System (INIS)

    Lavoie, J.; Beaudet, Y.; Letourneau, C.; Godbout, S.; Lemay, S.; Belzile, M.; Lachance, I.; Pouliot, F.

    2006-01-01

    A new regulation regarding agricultural operations in Quebec was passed in June 2002. It stated the new standards for managing phosphorous generated from animal livestock. The regulation is intended to protect the environment, more specifically, water, soil and air quality. This new regulation stipulates that agricultural producers acquire a balanced phosphorous assessment by 2010. In order to achieve this, a system is needed to separate solid and liquid pig manure on a daily basis. Producers must also comply with environmental requirements on odour elimination and atmospheric control. The proposed solid-liquid separation system would improve the indoor and outdoor air quality at pig housing facilities by reducing toxic gas and bioaerosol formation. In addition, it would contribute to stream purification. The solid-liquid separation technique was successfully tested in a pilot project at a mini pig housing facility. It was concluded that type of separation equipment system could readily used for other types of animal farming, such as cattle raising. 41 refs., 13 tabs., 12 figs

  5. DEVELOPMENT OF THE TEMPERATURE CONTROL OF THE HOME-STREET AND MANAGING EXECUTIVE EQUIPMENT

    Directory of Open Access Journals (Sweden)

    Doshenko G.G.

    2017-12-01

    Full Text Available A home-street temperature control device and executive equipment management have been developed, which is characterized by high reliability and comparatively low cost. Due to the improvement of the analog circuit it is ensured to increase the speed of the developed device and its reliability. Practical recommendations for the manufacture of a home-street temperature control device and executive equipment management are presented

  6. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  7. Analysis of QA audit checklist for equipment suppliers

    International Nuclear Information System (INIS)

    Tian Xuehang

    2012-01-01

    Eleven aspects during the equipment manufacturing by the suppliers, including the guidelines and objectives of quality assurance, management department review, document and record control, staffing and training, design control, procurement control, control of items, process control, inspection and testing control, non-conformance control, and internal and external QA audit, are analyzed in this article. The detailed QA audit checklist on these above mentioned aspects are described and the problems found in real QA audit are listed in this article. (authors)

  8. NPP capital equipment life control facilities and tools

    International Nuclear Information System (INIS)

    Nekrasov, A.V.; Proskuryakov, K.N.

    2009-01-01

    Algorithms and simulation package for calculation of eigen modes of coolant pressure oscillations in equipment of primary coolant circuit of WWER-1000 NPP, tuned-circuit Q-factor of an oscillating contour of the coolant, fluctuation frequencies pass band and attenuation factors of were developed. Calculation results for cases of presence and absence of gaseous state radiolysis products in the coolant were obtained. Results analysis makes it possible to disclose operating conditions which result in raised vibrations, and to develop control response in NPP industrial control system for their prevention [ru

  9. Strategy and implementation of resources control of key equipments in nuclear power plant

    International Nuclear Information System (INIS)

    Zha Qing

    2014-01-01

    The strategic resources of the construction of nuclear power plant, which include the main equipment of nuclear island, heavy forgings, the bottleneck equipment and strategic materials, is one of the key issues in the construction of nuclear power projects. The control of these strategic resources has become the focus of competition in industry and the major nuclear power groups are willing to fight for this huge advantages. The resource control strategies of key equipment of nuclear power projects are analyzed in this paper. This paper put forward specific measures and methods for the strategic resources control. By the application to a plurality of nuclear power engineering construction projects, these specific measures and methods achieved good results and will be with important guidance and reference for the construction of future nuclear power projects in China. (author)

  10. Implementation of quality control program in radiodiagnostic services; Implementacion de un programa de control de calidad en servicios de radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Herrera S, A; Roas Z, N

    1996-12-31

    This monograph is the first version of the implementation of the quality control programme in radiology diagnostic services. Here all information related to diagnostic quality to better radiation protection to patients and personnel was collected. The programme was implemented on the X-ray equipment at three hospitals (named hospital A, hospital B and hospital C) and included the evaluation of technical parameters such as kilovolts, exposition time, filtration, fields. In addition, dark room, chassis and image intensifiers were also evaluated. The procedures to carry out the quality control and the manner in which the observations, conclusions and recommendations should be formulated are based on documents issued by the International Commission on Radiological Protection (I.C.R.P.), International Atomic Energy Agency (I.A.E.A.) and World Health Organization (W.H.O.).

  11. Electromagnetic compatibility for the control and command equipments in nuclear power plants

    International Nuclear Information System (INIS)

    Buisson, J.

    1985-06-01

    Different kinds of electrical interference produce some disturbance on electronic sub-assemblies used to assume the control and the command of nuclear reactors. Following interferences are described: power supply lines perturbations, potential difference between grounding connections, electromagnetic fields. A method is described for testing the EMC of different equipments. The advantages of this method are: no destructive method, usable for testing equipment ''in situ'' in operating conditions on nuclear power plant, usable for testing equipment before operating conditions (acceptance test), level of the testing signals similar to the electrical interference level induced by the electromagnetic environment in normal operating conditions, no particular equipment and installation for test are required [fr

  12. Using a tandem ionization chamber for quality control of X-ray beams

    International Nuclear Information System (INIS)

    Yoshizumi, Maira T.; Caldas, Linda V.E.

    2011-01-01

    X-ray beam qualities are defined by both the mean energies and by the half-value layers (HVL). Many international protocols use the half-value layer and the beam voltage to characterize the X-ray beam quality. A quality control program for X-ray equipment includes the constancy check of beam qualities, i.e., the periodical verification of the half-value layer, which can be a time consumable procedure. A tandem ionization chamber, developed at Instituto de Pesquisas Energeticas e Nucleares, was used to determine the HVL and its constancy for five radiotherapy standard beam qualities. This ionization chamber is composed by two sensitive volumes with inner electrodes made of different materials: aluminum and graphite. The beam quality constancy check test was performed during two months and the maximum variation obtained was 1.24% for the radiation beam quality T-10. This result is very satisfactory according to national recommendations. (author)

  13. Changes in radiological protection and quality control in Spanish dental installations: 1996-2003.

    Science.gov (United States)

    Alcaraz-Baños, Miguel; Parra-Pérez, María del Carmen; Armero-Barranco, David; Velasco-Hidalgo, Francisco; Velasco-Hidalgo, Esteban

    2009-10-01

    The European Union has established specific directives concerning radiological protection which are obligatory for member States. In addition, all Spanish dental clinics with radiological equipment are required to have an annual quality control check. To analyze the effect of new European legislation on dental radiological practice in Spain and to determine whether it has resulted in lower doses being administered to patients. A total of 10,171 official radiological quality control reports on Spanish dental clinics, covering 16 autonomous regions, were studied following the passing of Royal Decree 2071/1995 on quality criteria in radiodiagnostic installations. The reports, compiled by U.T.P.R Asigma S.A., a company authorised by the Nuclear Safety Council, cover the years 1996 to 2003, which has enabled us to monitor the evolution of radiological procedures in dental clinics over a seven year period. According to the reports for 2003, 77.3 % of clinics complied with EU requirements, using equipment of 70 kVp, 8 mA, 1.5 mm Al filters, with a collimator length of 20 cm. However, non-compliance was detected in approximately a third (30.8%) of the equipment inspected: alterations in the kilovoltage used, exposure time, performance of the tubing, dosage, linearity/intensity of current and acoustic-luminous signal 6.86%. The mean skin dose reached 3.11 mGy for patients who received an x-ray of an upper molar, representing a decrease of 18% over the seven years studied. there has obviously been a general improvement in the parameters studied, but only 77.3% of the installations complied fully with official EU regulations concerning dental radiological protection.

  14. Enhancing spill prevention and response preparedness through quality control techniques

    International Nuclear Information System (INIS)

    Jones, M.A.; Butts, R.L.; Pickering, T.H.; Lindsay, J.R.; McCully, B.S.

    1993-01-01

    The year 1990 saw passage of federal and state oil spill legislation directing the US Environmental Protection Agency and the Florida Department of Environmental Regulation to require on shore bulk petroleum storage facilities to improve their oil spill response and prevention capabilities. The Florida Power ampersand Light Company (FPL), to address concerns arising out of several recent significant spills which had occurred worldwide, and to examine its current situation with regard compliance with the new laws, formed a quality improvement interdepartmental task team in July 1989. Its mission was to reduce the potential for oil spills during waterborne transportation between FPL's fuel oil terminals and its power plants and during transfer and storage of oil at these facilities. Another objective of the team was to enhance the company's spill response preparedness. Using quality control tools and reliability techniques, the team conducted a detailed analysis of seven coastal power plants and five fuel oil terminal facilities. This analysis began with the development of cause-and-effect diagrams designed to identify the root causes of spills so that corrective and preventive actions could be taken. These diagram are constructed by listing possible causes of oil spills under various major categories of possible system breakdown, such as man, method, equipment, and materials. Next, potential root causes are identified and then verified. The team identified the occurrence of surface water oil spill and reduced spill response capability as primary concerns and accordingly constructed cause-and-effect diagrams for both components. Lack of proper procedures, failure of control equipment, and inadequate facility design were identified as potential root causes leading to surface water oil spills. Lack of proper procedures, an inconsistent training program, and response equipment limitations were identified as potential root causes affecting oil spill response capabilities

  15. Rules on the Inspection of Gamma Radiography Equipment

    International Nuclear Information System (INIS)

    1981-01-01

    These Rules issued by the State Institute of Radiation Hygiene (SIS) set out the obligations of licences and vendors of gamma radiography equipment for purposes of quality control. The Rules provide for a programme of periodic inspections and services by personnel approved by SIS. (NEA)

  16. Total Quality Control Points on Clean Area of Renewable Equipment%探讨再生器械回收清洗区全程质量控制点

    Institute of Scientific and Technical Information of China (English)

    曹秋莲; 赵玛丽

    2011-01-01

    Objective To explore all the quality control problems on clean area of renewable equipment. Methods The causes were analyzed, such as the manipulation of cleaning personnel capacity, personal protective measures, recovery of pre-treatment, classification before cleaning, cleaning and disinfection reagent configuration and use of clean water for the quality of scientific management. Results The previous recovery of clean supply room management of ambiguous situation was changed and the cost of medical equipment was reduced. Conclusion The complete recovery of cleaning process will not only lay the foundation for follow-up work, but also improve the use security.%目的:探讨回收清洗区全程质量控制的问题.方法:通过对清洗人员的操控能力、个人防护措施、回收预处理、器械清洗前分类、清洗消毒试剂的配置及使用、清洗用水质量进行控制,并进行因为分析,以迭到科学管理.结果:改变了以往供应室回收清洗管理模糊的状况,降低了医疗器械成本.结论:完善的回收清洗流程不仅为后续工作打好了基础,而且提高了使用安全性.

  17. Operation control equipment for BWR type reactor

    International Nuclear Information System (INIS)

    Izumi, Masayuki; Takeda, Renzo.

    1981-01-01

    Purpose: To improve the temperature balance in a feedwater heater by obtaining the objective value of a feedwater enthalpy upon calculation of respective measured values and controlling the opening or closing of an extraction valve so that the objective value may coincide with the measured value, thereby averaging the axial power distribution. Constitution: A plurality of stages of extraction lines are connected to a turbine, and extraction valves are respectively provided at the lines. By calculating the measured values of ractor pressure, reactor core flow rate, vapor flow rate and reactor core inlet enthalpy determined to predetermined value using heat balance the objective feedwater enthalpy is obtained, is fed as an extraction valve opening or closing signal from a control equipment, the extraction stages of the turbine extraction are altered in accordance with this signal, and the feedwater enthalpy is controlled. (Sekiya, K.)

  18. General Guidelines for Remote Operation and Maintenance of Pyroprocess Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. H.; Park, B. S.; Park, H. S.; Lee, H. J.; Choi, C. W.; Lee, J. K

    2007-12-15

    As the pyroprocess handle the high radioactive materials, a high radioactive material handling facility required high safety, radioactive shielding, strict quality control, and the remote handling equipment of high technology. This report describes the guidelines of for pyroprocess based the design guides for radioactive material handling facility and equipment from American Nuclear Society(ANS), design guidelines for remotely maintained equipment from Oak Ridge National Laboratory(ORNL), and the experience of design for ACP equipment installed at the ACPF(Advanced Conditioning Process Facility). The General guidelines in this report are as follows. The General guidelines for remote operation and maintenance of pyroprocess equipment: Pyroprocess, Remote handling equipment for pyroprocess, General guide for remote operation and maintenance, general guidelines for the design of remotely operated and maintained equipment, Estimation and analysis for remote maintenance.

  19. Equipment for radiography in Yugoslavia - security and radiation protection

    International Nuclear Information System (INIS)

    Dobrijevic, R.; Vucina, J.

    1998-01-01

    Nondestructive method of material control by using radioisotopes is developed in Yugoslavia. This method of quality control is professionally performed by 30 firms. This paper presents the overview of the equipment used in the industrial radiography by using radioisotopes. Special attention was devoted to the security during the work and to the radiation protection of the operator and other personnel around the working place. In general it could be concluded that the main drawback which influences the security is the fact that most cases old and whom out equipment is in use. Other factors influencing the security are also discussed. (author)

  20. Quality control of radionuclide calibrators used in nuclear medicine services in the Brazilian northeast region

    International Nuclear Information System (INIS)

    Fragoso, Maria C.F.; Albuquerque, Antonio M.S.; Oliveira, Mercia L.; Lima, Ricardo A.; Lima, Fabiana F.

    2011-01-01

    The radionuclide calibrators are essential instruments in nuclear medicine services in order to activity determination of radiopharmaceuticals which will be administered to the patients. Inappropriate performance of these equipment could provide underestimation or overestimation of the activity, compromising the success of diagnosis or therapeutic procedures. To ensure the satisfactory performance of the radionuclide calibrators, quality control tests are recommended by national and international guides. The aim of this work was evaluate the establishment of the quality control program in the radionuclide calibrators at medicine nuclear services in the Brazilian northeast region, highlighting the tests and their frequencies. (author)

  1. Technical preparation of the Yuzhteploehnergomontazh trust for technological equipment mounting

    International Nuclear Information System (INIS)

    Zayats, A.I.

    1982-01-01

    Measures of technical preparation for equipment mounting at the Zaporozhe NPP developed with the Yuzhteploehnergomontazh trust experts are considered. These measures envisage the construction of mounting base of heat facilities, calculation of labour contents and determination of necessary quantity of mounters, development of optimal flowsheet of mounting control, improvement of mounting qualification and creation of stable collective body, improvement of technical level of mounting and welding works, organizational-technical measures on mounting logistics. Factors affecting negatively technical preparation quality of equipment mounting at the Zaporozhe NPP are discussed. The flowsheet of mounting control is presented

  2. Principles and Practices for Quality Assurance and Quality Control

    Science.gov (United States)

    Jones, Berwyn E.

    1999-01-01

    Quality assurance and quality control are vital parts of highway runoff water-quality monitoring projects. To be effective, project quality assurance must address all aspects of the project, including project management responsibilities and resources, data quality objectives, sampling and analysis plans, data-collection protocols, data quality-control plans, data-assessment procedures and requirements, and project outputs. Quality control ensures that the data quality objectives are achieved as planned. The historical development and current state of the art of quality assurance and quality control concepts described in this report can be applied to evaluation of data from prior projects.

  3. THE CONCEPTUAL FRAMEWORK OF FORMING THE PRODUCT QUALITY CONTROL STRATEGY OF ROAD-BUILDING ENGINEERING ENTERPRISES

    Directory of Open Access Journals (Sweden)

    Mariia Sadova

    2017-11-01

    Full Text Available The purpose of the work is the need of the theoretical justification and the development of relevant scientific and methodological approaches to the management of the road production quality of machine-building enterprises; it led to the choice of research topics. Methodology. Taking into account the value of existing methods of quality management of road production engineering companies, currently a particular attention requires improvement of the quality control functions: analysis, evaluation, planning and quality control during the operation of road-building equipment, because existing economic practices and quality management approaches are built on classical principles of ISO 9001, and in the practical application do not solve all of the drawbacks of traditional management models, but only smooth them a little. Therefore, the formation of the quality management strategy for the road production of mechanical engineering is essential to ensure the competitiveness of products and enterprises of the road-building complex in the period of development of market relations in the economy. The results showed that the current market conditions impose strict requirements to all production areas of the society. Especially stringent are requirements for the road construction, because the quality of the construction of the subgrade, covering roads and curbs, grading and soil compaction under different conditions of terrain and driving safety depends on people's lives. This factor determines the exceptional quality requirements for roadbuilding equipment, which must be reliable, functional and able to meet the totality of the design and operational characteristics of the road. Further European integration of Ukraine, deepening of external economic relations with the European countries are responsible for the growing needs of the national economy in the development and expansion of the transport network. However, large-scale road construction and repair

  4. Quality assurance services

    International Nuclear Information System (INIS)

    For over 20 years the quality assurance services at the Springfields Laboratories have been concerned with manufacturing both simple and complex engineering products to the highest standard. The scientists working there have considerable expertise in the practical application of quality control and the development and design of inspection and non-destructive testing equipment. The folder contains six sheets or leaflets illustrating the work and equipment. The subjects are the mechanical standards laboratory, non-destructive testing, the digitising table, the peripheral camera, automated measurement, data handling and presentation, and the computer controlled three axis co-ordinate measuring machine. (U.K.)

  5. Checking quality control?

    DEFF Research Database (Denmark)

    Brodersen, Lars

    2005-01-01

    How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?......How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?...

  6. 77 FR 35310 - Revisions to the Export Administration Regulations (EAR): Control of Military Training Equipment...

    Science.gov (United States)

    2012-06-13

    ... for foreign made ``military commodities'' that incorporate more than 10% U.S.-origin ``600 series... Military Training Equipment and Related Items the President Determines No Longer Warrant Control Under the... longer warrant control under Category IX (Military Training Equipment and Training) of the United States...

  7. Quality assurance in mammography

    International Nuclear Information System (INIS)

    Fosmark, H.; Olerud, H.M.

    1992-01-01

    Guidelines in mammography are given, including competence of staff, performance of equipment and quality control procedures. The purpose of the guidelines is to ensure optimum diagnostic quality. 5 refs

  8. Research on Modularized Design and Allocation of Infectious Disease Prevention and Control Equipment in China.

    Science.gov (United States)

    Zhao, Xin; Wang, Yun-Dou; Zhang, Xiao-Feng; Gao, Shu-Tian; Guo, Li-Jun; Sun, Li-Na

    2017-06-01

    For the prevention and control of newly emergent or sudden infectious diseases, we built an on-site, modularized prevention and control system and tested the equipment by using the clustering analysis method. On the basis of this system, we propose a modular equipment allocation method and 4 applications of this method for different types of infectious disease prevention and control. This will help to improve the efficiency and productivity of anti-epidemic emergency forces and will provide strong technical support for implementing more universal and serialized equipment in China. (Disaster Med Public Health Preparedness. 2017;11:375-382).

  9. The Role Of Quality Assurance Program For Safety Operation Of Nuclear Installations

    International Nuclear Information System (INIS)

    Harjanto, N.T.; Purwadi, K.P.; Boru, D.S.; Farida; Suharni

    2000-01-01

    Nuclear installations expose potential hazard of radiation, therefore in their construction, operation and maintenance, it is necessary to consider safety aspect, in which the safety requirements which has been determined must be met. One of the requirements that is absolutely needed is quality assurance, which covers arrangement of quality assurance program, organization and administration of the implementation of quality assurance, and supervision. Quality Assurance program is a guideline containing quality policies and basic determination on the realization of activities that effect the quality of equipment's and items used in the operation of nuclear installations in order that the operation of nuclear installation can run safety and in accordance with their design aims and operation limits. Quality Assurance Program includes document control, design control, supply control, control of equipment s and items, operation/process control, inspection and control of equipment test, and control of nonconformance and corrections. General system of nuclear installation operation is equipped with safety and supporting systems. These systems must apply the quality assurance program that cover control of activities in the systems. In the implementation of the quality assurance program, it is necessary to establish procedures, work guidelines/instructions, and quality recording that constitutes documents of quality system 2 nd , 3 th , and 4 th level after the quality assurance program. To ensure the effectivity and to prove whether the realization of the program has been pursuant to the determined requirements, an internal audit must be conducted accordingly

  10. Quality control of stainless steel pipings for nuclear power generation

    International Nuclear Information System (INIS)

    Miki, Minoru; Kitamura, Ichiro; Ito, Hisao; Sasaki, Ryoichi

    1979-01-01

    The proportion of nuclear power in total power generation is increasing recently in order to avoid the concentrated dependence on petroleum resources, consequently the reliability of operation of nuclear power plants has become important. In order to improve the reliability of plants, the reliability of each machine or equipment must be improved, and for the purpose, the quality control at the time of manufacture is the important factor. The piping systems for BWRs are mostly made of carbon steel, and stainless steel pipings are used for the recirculation system cooling reactors and instrumentation system. Recently, grain boundary type stress corrosion cracking has occurred in the heat-affected zones of welded stainless steel pipings in some BWR plants. In this paper, the quality control of stainless steel pipings is described from the standpoint of preventing stress corrosion cracking in BWR plants. The pipings for nuclear power plants must have sufficient toughness so that the sudden rupture never occurs, and also sufficient corrosion resistance so that corrosion products do not raise the radioactivity level in reactors. The stress corrosion cracking occurred in SUS 304 pipings, the factors affecting the quality of stainless steel pipings, the working method which improves the corrosion resistance and welding control are explained. (Kako, I.)

  11. Automated Risk Control in Medical Imaging Equipment Management Using Cloud Application

    Directory of Open Access Journals (Sweden)

    Sally M. Ghanem

    2018-01-01

    Full Text Available Medical imaging equipment (MIE is the baseline of providing patient diagnosis in healthcare facilities. However, that type of equipment poses high risk for patients, operators, and environment in terms of technology and application. Considering risk management in MIE management is rarely covered in literature. The study proposes a methodology that controls risks associated with MIE management. The methodology is based on proposing a set of key performance indicators (KPIs that lead to identify a set of undesired events (UDEs, and through a risk matrix, a risk level is evaluated. By using cloud computing software, risks could be controlled to be manageable. The methodology was verified by using a data set of 204 pieces of MIE along 104 hospitals, which belong to Egyptian Ministry of Health. Results point to appropriateness of proposed KPIs and UDEs in risk evaluation and control. Thus, the study reveals that optimizing risks taking into account the costs has an impact on risk control of MIE management.

  12. Evaluation of the quality parameters of mobile X-ray units equipment used for radiodiagnostic in public institutions of Sergipe

    International Nuclear Information System (INIS)

    Oliveira, Celso A.; Santos, Lucas R. dos; Silva, Fabio A.R.; Souza, Divanizia N.

    2008-01-01

    This project was started having as main objective to observe the diagnosis quality offered by mobile x-ray units utilized in a health care institution. In this work we are reporting the first results obtained from three equipment used by a public institution inspected on the state of Sergipe, Brazil. During the verification visits at institution the radiology technicians were questioned about specific maintenances performed on the equipment and the operating procedures used. Moreover, some beams parameters were verified as dose, dose rate, and peak voltage and exposition time. The obtained results showed a good index of reproducibility and linearity of the operation parameters, of the kerma air rate and exposition time. However, to the kVp tests were observed variations up to 20% between the nominal value used and the value measured on the X-ray units. The test results of the focal point are in accordance with the acceptable standards. The analyses of equipment and the answered questionnaire showed that have not been performed periodic maintenances in the equipment, therefore some of the equipment do not present satisfactory requirements of operating, their do not make use of luminous field nether collimator or the scale meter to checking the source to surface distance. The main factor that can explains the negative results is the absence of a continue quality program associated with the unsatisfactory maintenances. The health care institutions evaluated are introducing a permanent quality program to the X-ray devices. (author)

  13. Quality assurance in dental radiology

    International Nuclear Information System (INIS)

    Lorber, C.G.

    1992-01-01

    The quality criteria that have determined and the quality optimization measures defined have to regularly checked in order to guarantee the quality standards. The quality control programme is laid down in the publiction of the WHO (ISO 3534-1977), referring to the quality control of equipment, film processing techniques, and to the qualification of the medical and technical personnel. (DG) [de

  14. Dosimetry and quality control in radiodiagnosis

    International Nuclear Information System (INIS)

    Le Gouic, M.

    1983-07-01

    This work deals with physics of radiodiagnosis. In a first part a study of the characteristics of different kinds of radiological equipments and a quality assurance of some of them (standard radiography, coronarography and computed tomography) have been performed. The second part deals with patient irradiation. After a bibliographic study of radiodiagnosis dosimetry, two kinds of dosimetric measures have been made: ''in vitro'' measures, using a phantom, that had allowed to calibrate the equipment and to improve the individual irradiation card, and ''in vivo'' measures. For the first types of measures ionization chambers, have been used for the second thermoluminescent dosimeters [fr

  15. Uncertainties of exposure-related quantities in mammographic x-ray unit quality control

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Pattison, John E.; Bibbo, Giovanni

    2006-01-01

    Breast screening programs operate in many countries with mammographic x-ray units subject to stringent quality control tests. These tests include the evaluation of quantities based on exposure measurements, such as half value layer, automatic exposure control reproducibility, average glandular dose, and radiation output rate. There are numerous error sources that contribute to the uncertainty of these exposure-related quantities, some of which are unique to the low energy x-ray spectrum produced by mammographic x-ray units. For each of these exposure-related quantities, the applicable error sources and their magnitudes vary, depending on the test equipment used to make the measurement, and whether or not relevant corrections have been applied. This study has identified and quantified a range of error sources that may be used to estimate the combined uncertainty of these exposure-related quantities, given the test equipment used and corrections applied. The uncertainty analysis uses methods described by the International Standards Organization's Guide to the Expression of Uncertainty in Measurement. Examples of how these error sources combine to give the uncertainty of the exposure-related quantities are presented. Using the best test equipment evaluated in this study, uncertainties of the four exposure-related quantities at the 95% confidence interval were found to be ±1.6% (half value layer), ±0.0008 (automatic exposure control reproducibility), ±2.3% (average glandular dose), and ±2.1% (radiation output rate). In some cases, using less precise test equipment or failing to apply corrections, resulted in uncertainties more than double in magnitude

  16. Noise control of radiological monitoring equipment

    International Nuclear Information System (INIS)

    Rubick, R.D.; Stevens, W.W.; Burke, L.L.

    1998-01-01

    Although vacuum pumps on continuous air monitors (CAMs) do not produce noise levels above regulatory limits, engineering controls were used to establish a safer work environment. Operations performed in areas where CAMs are located are highly specialized and require precision work when handling nuclear materials, heavy metals, and inert gases. Traditional methods for controlling noise such as enclosing or isolating the source and the use of personal protection equipment were evaluated. An innovative solution was found by retrofitting CAMs with air powered multistage ejectors pumps. By allowing the air to expand in several chambers to create a vacuum, one can eliminate the noise hazard altogether. In facilities with adequate pressurized air, use of these improved ejector pumps may be a cost-effective replacement for noisy vacuum pumps. A workplace designed or engineered with noise levels as low as possible or as close to background adds to increased concentration, attention to detail, and increased production

  17. Engineering Work Plan for the Development of Phased Startup Initiative (PSI) Phases 3 and 4 Test Equipment

    International Nuclear Information System (INIS)

    PITNER, A.L.

    2000-01-01

    A number of tools and equipment pieces are required to facilitate planned test operations during Phases 3 and 4 of the Phased Startup Initiative (PSI). These items will be used in assessing residual canister sludge quantities on cleaned fuel assemblies, sorting coarse and fine scrap fuel pieces, assessing the size distribution of scrap pieces, loading scrap into a canister, and measuring the depth of the accumulated scrap in a canister. This work plan supercedes those previously issued for development of several of these test items. These items will be considered prototype equipment until testing has confirmed their suitability for use in K West Basin. The process described in AP-EN-6-032 will be used to qualify the equipment for facility use. These items are considered non-OCRWM for PSI Phase 3 applications. The safety classification of this equipment is General Service, with Quality Level 0 (for PSI Phase 3). Quality Control inspections shall be performed to verify basic dimensions and overall configurations of fabricated components, and any special quality control verifications specified in this work plan (Section 3.1.5). These inspections shall serve to approve the test equipment for use in K West Basin (Acceptance Tag). This equipment is for information gathering only during PSI Phases 3 and 4 activities, and will be discarded at the completion of PSI. For equipment needed to support actual production throughput, development/fabrication/testing activities would be more rigorously controlled

  18. Quality controls in intensity-modulated conformational radiotherapy. S.F.P.M. report nr 26, January 2010

    International Nuclear Information System (INIS)

    Valinta, Danielle; Poinsignon, Anne; Caron, Jerome; Dejean, Catherine; Corsetti, Dominique; Marcie, Serge; Mazurier, Jocelyne; Naudy, Suzanne; Aget, Helene; Marchesi, Vincent; Vieillevigne, Laure; Dedieu, Veronique; Bramoule, Celine; Caselles, Olivier; Lacaze, Brigitte; Mazurier, Jocelyne

    2009-08-01

    This report proposes a comprehensive presentation of the different controls which can be performed for the implementation of 3D intensity-modulated conformal radiation therapy (IMCR). The authors first present the IMCR principle by describing modes of production of modulated beams, the practical realisation of intensity modulation with Multi Leaf Collimator (MLC), multi leaf collimators, and the inverse planning system. They present the quality control of the accelerator (pre-requisites, linearity of the monitor chamber, symmetry and homogeneity), the quality control of multi leaf collimators (prerequisites, leaf absolute calibration, static mode, dynamic mode), the quality control of the treatment planning system (prerequisites, tests specific to IMCR, example in dynamic mode with the chair test), the quality control of the treatment plan (objective, necessary equipment and software solutions, measurement of point absolute dose, control of dose distribution, independent calculation of the number of monitor units), and the treatment verification (pre-treatment verification, patient repositioning during treatment). Finally, they indicate human means required for IMCR implementation, and formulate some recommendations for this implementation

  19. Controller recovery from equipment failures in air traffic control: A framework for the quantitative assessment of the recovery context

    International Nuclear Information System (INIS)

    Subotic, Branka; Schuster, Wolfgang; Majumdar, Arnab; Ochieng, Washington

    2014-01-01

    Air Traffic Control (ATC) involves a complex interaction of human operators (primarily air traffic controllers), equipment and procedures. On the rare occasions when equipment malfunctions, controllers play a crucial role in the recovery process of the ATC system for continued safe operation. Research on human performance in other safety critical industries using human reliability assessment techniques has shown that the context in which recovery from failures takes place has a significant influence on the outcome of the process. This paper investigates the importance of context in which air traffic controller recovery from equipment failures takes place, defining it in terms of 20 Recovery Influencing Factors (RIFs). The RIFs are used to develop a novel approach for the quantitative assessment of the recovery context based on a metric referred to as the Recovery Context Indicator (RCI). The method is validated by a series of simulation exercises conducted at a specific ATC Centre. The proposed method is useful to assess recovery enhancement approaches within ATC centres

  20. Overall Equipment Effectiveness Implementation Criteria

    Science.gov (United States)

    Abramova, I. G.; Abramov, D. A.

    2018-01-01

    This article documents the methods applied in production control technics specifically focused on commonly used parameter OEE (Overall Equipment Effectiveness). The indicators of extensive and intensive use of equipment are considered. Their appointment this is comparison in the same type of production within the industry and comparison of single-type and / or different types of equipment in terms of capacity. However, it is shown that there is no possibility of revealing the reasons for the machine’s operation: productive / unproductive, with disturbances. Therefore, in the article reveals the approaches to calculating the indicator characterizing the direct operation of the equipment. The Machine Load coefficient is approaching closely to the indicator of the efficiency of the use of equipment. Methods analysis is proceeded through the historically applied techniques such as “Stopwatch” and “Motion” studies. Was performed the analysis of the efficiency index of OEE equipment using the comparable indexes performance of equipment in the Russian practice. An important indicator of OEE contains three components. The meaning of each of them reflects historically applicable indicators. The value of the availability of equipment indicator is close to the value of the equipment extensibility index. The value of the indicator of the efficiency of work can be compared with the characteristic of the capacity of the equipment and the indicator of the quality level can meet the requirements for compliance with the manufacturing technology. Shown that the sum of the values of the coefficient of “Availability” of the equipment and the value of the “Factor of compaction of working hours” are one. As well as the total value of the indicator “level of quality” and the coefficient of marriage given in the result unit. The measurability of the indicators makes it possible to make a prediction about efficiency of the equipment.

  1. Physical aspects of quality assurance in radiotherapy: A protocol for quality control; Aspectos fisicos de la garantia de calidad en radioterapia: Protocolo de control de calidad

    Energy Technology Data Exchange (ETDEWEB)

    Aguirre, J F [Radiological Physics Center, M.D. Anderson Hospital, Houston (United States); Alfonso-Laguardia, R [Instituto Nacional de Oncologia y Radiobiologia (INOR), La Habana (Cuba); Andreo, P [International Atomic Energy Agency, Vienna (Austria); Brunetto, M [FaMAF (UNC), Centro Medico Dean Funes, Cordoba (Argentina); Marenco-Zuniga, H [Hospital Mexico, San Jose (Costa Rica); Gutt, F [Instituto Venezolano de Investigaciones Cientificas, LSCD, Caracas (Venezuela); Torres-Calderon, A [Hospital Siglo XXI, Ciudad de Mexico (Mexico)

    2000-06-01

    In consistency with the increasing requests from Member States for establishing radiotherapy programmes, an IAEA Technical Co-operation project was initiated in Latin America aimed at improving the physical aspects (as a complement to the clinical issues) of quality assurance in radiotherapy; this ARCAL XXX project (RLA/6/032) was classified as a Model Project of the IAEA. Among the important outcomes of the project were (i) the training of a considerable number of medical physicists in hospitals of the region, (ii) the development of a protocol for quality control procedures, and (iii) the organization of quality audit site visits (to the participant countries) where the implementation in hospitals of the developed quality control procedures is verified. The present publication is the protocol for quality control of the physical aspects of radiotherapy. It contains detailed procedures on what should be measured by a medical physicist in a radiotherapy treatment unit and related equipment, and how this should be made. The latter is made through several appendices, which make the document rather unique. The protocol was developed by medical physicists of the region for the professionals of the region, and it is the first document of this kind ever written in Spanish. A training course was organized in November 1998 (Havana, Cuba) where its practical implementation was taught. There are plans to have this document translated into different languages for the various regions having similar TC projects. (author)

  2. Mapping of the radiation field of a mammography equipment using molybdenum and rhodium filters

    International Nuclear Information System (INIS)

    Barreira, Jacqueline S.; Campos, Daniela; Vivolo, Vitor

    2014-01-01

    The use of X rays for diagnostic radiology is very common and important to Medicine, including mammographic diagnosis focusing decreasing of the doses applied to the patients and preserving high quality of the diagnostic image. A quality control program of the irradiation systems it is very necessary. The Instruments Calibration Laboratory (LCI) of IPEN perform calibration in dosemeters used in radiation dosimetry (in diagnostic radiology) for many years. The objective of that paper is determining the point of greatest intensity of the beam issued by the mammography equipment. Exposures were made with filters Rhodium and Molybdenum. That mapping is important before applied a routine quality control program of the mammography equipment and the calibration of instruments in the diagnosis. (author)

  3. Development of augmented reality system for servicing electromechanical equipment

    Science.gov (United States)

    Zhukovskiy, Y.; Koteleva, N.

    2018-05-01

    Electromechanical equipment is widely used. It is used in industrial enterprises, in the spheres of public services, in everyday life, etc. Maintenance servicing of electromechanical equipment is an important part of its life cycle. High-quality and timely service can extend the life of the electromechanical equipment. The creation of special systems that simplify the process of servicing electromechanical equipment is an urgent task. Such systems can shorten the time for maintenance of electrical equipment, and, therefore, reduce the cost of maintenance in general. This article presents an analysis of information on the operation of service services for maintenance and repair of electromechanical equipment, identifies the list of services, and estimates the time required to perform basic service operations. The structure of the augmented reality system is presented, the ways of interaction of the augmented reality system with the automated control systems working at the enterprise are presented.

  4. Quality control of intelligence research

    International Nuclear Information System (INIS)

    Lu Yan; Xin Pingping; Wu Jian

    2014-01-01

    Quality control of intelligence research is the core issue of intelligence management, is a problem in study of information science This paper focuses on the performance of intelligence to explain the significance of intelligence research quality control. In summing up the results of the study on the basis of the analysis, discusses quality control methods in intelligence research, introduces the experience of foreign intelligence research quality control, proposes some recommendations to improve quality control in intelligence research. (authors)

  5. Changes in equipment and image quality. Impact of one year Austrian breast cancer early detection programme; Aenderungen in der Geraetelandschaft und Bildqualitaet. Auswirkungen nach einem Jahr Oesterreichischem Brustkrebsfrueherkennungsprogramm

    Energy Technology Data Exchange (ETDEWEB)

    Menhart, S.; Osanna-Elliott, A.; Semturs, F.; Schloegl, C.; Wildner, S.; Zwettler, G. [AGES, Wien (Austria). Referenzzentrum fuer technische Qualitaetssicherung im Brustkrebsfrueherkennungsprogramm

    2015-07-01

    The nationwide Austrian Breast Cancer Early Detection Programme (''BKFP'') started in January 2014. The Austrian Agency for Health and Food Safety Ltd. was entrusted with running the reference center for technical quality control (''RefZQS'') on April 1, 2014. The quality of the radiologists' equipment is evaluated against the standards described in the EUREF-Oeprotocol, which is based on the European guidelines for quality assurance in breast cancer screening and diagnosis (EPQC V4, 2006) and has been optimized for Austrian requirements. In its first year of operation the RefZQS has controlled the entire equipment (mammography, periphery and ultrasound system) of all participating radiologists. A significant number of systems had to be adjusted to meet the EUREF-Oecriteria. Some of the systems could not be adjusted accordingly, and had to be replaced. In the wake of the start of the screening programme, several sites switched from CR to more modern DR systems, yielding a significant benefit by reduction of radiation burden. The most important data after one year of RefZQS, especially according to adjustments and replacements, are presented.

  6. The use of fuzzy logic in quality control testing of automotive and tractor equipment

    Directory of Open Access Journals (Sweden)

    Korobko А.

    2016-08-01

    Full Text Available The article analyzes the relevance of the research topics, defines goals and objectives, subject and object of research. On the basis of the literature analysis, the following eduction was made: not all the test methods in road and agricultural vehicles (tractors contribute to the effective implementation of the requirements of normative documents including international, inter-laboratory comparative tests. The approach in laboratory testing to the synthesis adaptive system of metrological assurance the use of fuzzy logic is proposed. These labs conduct testing of automotive and tractor equipment. The decision is under risk. The scheme of metrological assurance system covers all parties to ensure the necessary accuracy of measurements and tests; the necessary normative-technical documentation is provided; availability of measuring instruments and test equipment, standards and reference measures; availability of qualified personnel; the assurance that test results are accurate (correct and precision; provides effective decisions based on objective information.

  7. Interaction between production control and quality control

    NARCIS (Netherlands)

    Bij, van der J.D.; Ekert, van J.H.W.

    1999-01-01

    Describes a qualitative study on interaction between systems for production control and quality control within industrial organisations. Production control and quality control interact in a sense. Good performance for one aspect often influences or frustrates the performance of the other. As far as

  8. The research on information security technology for the industrial control system of special equipment

    International Nuclear Information System (INIS)

    Chen Ligang; Liu Hongye; Zhang Wei; Sun Jianying; Lan Peng; Dai Sidan

    2014-01-01

    With the rapid development of information technology in enterprise application, industrial control network and management network is becoming more and more closely linked. Development and application of special equipment control system from the traditional industrial control system, not considered when designing communication security problem mainly, therefore, the industrial control system opened at the same time, isolation control system and the outside was weakened, the safety problems of industrial control system had become more and more serious. The practical application combined with the special equipment control system, analysis and elaboration in view of security problems for the control network, also, provide appropriate security solutions for professional characteristics of industrial control network, design on process control system specially, provide security partition protection scheme, in order to improve security ability of industrial control system information. (authors)

  9. MRI quality control tools for procedures and analyses

    International Nuclear Information System (INIS)

    Di Nallo, A.M.; Ortenzia, O.; Benassi, M.; D'Arienzo, M.; Coniglio, D.

    2006-01-01

    Quality control in MRI includes acceptance tests on the installation of a new scanner and tests representative of the system's performance during clinical practice.The first tests are time consuming and carried out to evaluate the agreement of the system with the prescribed procurement specifications. The second tests identify the equipment malfunction requiring maintenance are not time consuming and are suited to a busy clinical scanner. The paper evaluates the feasibility of the AAPM protocols and proposes procedures and practical tools to achieve this purpose.The MRI images, captured from the scanner and transferred in DICOM (Digital Imaging and Communications in Medicine) format by a local network, are analyzed by computerized worksheets and commercial software

  10. Quality control in radiotherapy

    International Nuclear Information System (INIS)

    Batalla, A.

    2009-01-01

    The authors discuss the modalities and periodicities of internal quality control on radiotherapy installations. They indicate the different concerned systems and the aspects and items to be controlled (patient and personnel security, apparatus mechanical characteristics, beam quality, image quality, isodose and irradiation duration calculation, data transfer). They present the measurement instruments and tools used for the mechanical controls, dose measurement, beam homogeneity and symmetry, anatomic data acquisition systems, and dose distribution and control imagery calculation

  11. ECOLOGICAL CONTROL EQUIPMENT AND TECHNOLOGY OF UNDERWATER VEGETATION DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    V. TITINSCHNEIDER

    2008-10-01

    Full Text Available The excess of aquatic submerse vegetation development carries to the reduction of the real rearing area for the piscicultural material from the production farms and allow nestling of the ichthyophages bird species that decrease the fish production. Aquatic submerse vegetation stumble the utilization of aquatic zones for recreation and also wright function of basins utilized for the electric energy production, of micro electricity works through obstruction of the dams grid. The control of the aquatic submerse vegetation development, for Myriophyllum verticillatum, Ceratophyllum submersum, Urticularia vulgaris, Potamogeton natans, Nimphoides peltata species it is accomplish through the removing of some parts of these, preferably with all the stump system. Usually, these its accomplish with the floating equipments fit up with the thermic engines and the propulsion and governating elements who have harm over the fish and some others aquatic organisms through the noise, the displacing a large quality of water caused of propulsion systems and through the noxes elimination (flue, carburant trails, etc.. These technologies reside from the evacuation of the aquatic submerse vegetation and the stump systems of these with the help of an adjustable rake, hang up from the coast by a rope, wrapped to a drummer, who is trained by a motto-propeller group with a small installed power.

  12. Quality control and patient dose from X-ray examinations in some hospitals in Estonia

    International Nuclear Information System (INIS)

    Servomaa, A.; Rannikko, S.; Parviainen, T.; Holmberg, P.; Kuus, E.; Mueuersepps, T.; Jaerv, V.

    1995-01-01

    Quality control measurements of X ray diagnostic units were carried out in four hospitals in Estonia. Measurements were focused on the unit's technical performance, on image quality and on patient dose and film processing. The main problems are in the areas of image receptors and film processing: image receptors are of low speed type causing high patient doses and manual film processing results in low contrast and high base plus fog. Spatial resolution, both in film imaging and in image intensifiers, is reasonably good. It is recommended that quality assurance programmes be established, that basic measuring equipment be acquired and personnel assigned to perform such measurements be trained. (Author)

  13. Investigation of possible methods for equipment self-tests in digital radiology

    International Nuclear Information System (INIS)

    Zoetelief, J.; Idris, H. H. E.; Jansen, J. T. M.

    2005-01-01

    Quality control in digital radiology can be time-consuming. Equipment self-tests may significantly decrease staff workload. The two most essential parameters for radiology systems are image quality and patient dose. Concerning patient dose, information on the dose-area product (DAP) values generally forms the basis for assessment of patient dose. DAP-values can be measured using a transmission ionisation chamber or calculated from equipment settings. In the present study, various image quality parameters were derived using a contrast-detail (C-D) phantom. The investigation included a computer-aided assessment of C-D images, which produced various parameters, and also parameters based upon scoring by human observers. In addition, another parameter was calculated from modulation transfer function (MTF) measurements. The automatically calculated parameters showed good correlation with human readings, although the number of X-ray systems studied is still limited. We propose a combined evaluation of DAP and automatically calculated C-D or MTF parameters for equipment self-tests. (authors)

  14. Quality of care and investment in property, plant, and equipment in hospitals.

    Science.gov (United States)

    Levitt, S W

    1994-02-01

    This study explores the relationship between quality of care and investment in property, plant, and equipment (PPE) in hospitals. Hospitals' investment in PPE was derived from audited financial statements for the fiscal years 1984-1989. Peer Review Organization (PRO) Generic Quality Screen (GQS) reviews and confirmed failures between April 1989 and September 1990 were obtained from the Massachusetts PRO. Weighted least squares regression models used PRO GQS confirmed failure rates as the dependent variable, and investment in PPE as the key explanatory variable. Investment in PPE was standardized, summed by the hospital over the six years, and divided by the hospital's average number of beds in that period. The number of PRO reviewed cases with one or more GQS confirmed failures was divided by the total number of cases reviewed to create confirmed failure rates. Investment in PPE in Massachusetts hospitals is correlated with GQS confirmed failure rates. A financial variable, investment in PPE, predicts certain dimensions of quality of care in hospitals.

  15. Quality control of physician-performed mammography. Importance of original attempts to improve quality

    International Nuclear Information System (INIS)

    Nakayama, Takashi; Terada, Hiroshi; Kotsuma, Yoshikazu

    2006-01-01

    In order to perform effective breast cancer screening with mammography, family doctors should be encouraged to participate. At institutions without specific radiology technicians, physicians themselves are required to perform mammography and operate the equipment, otherwise it is difficult to consistently obtain good-quality mammograms. Our institutions have been given a grade ''A'' evaluation by the Central Committee for Quality Control of Mammographic Screening (CCQCMS), due largely to our own efforts and promotion. Here we report our experience in solving a number of problems that occurred during the establishment of our system. We used the SEPIO standard mammography apparatus with a MD-100/CM-H screen/filter system, and developed films using a TCX-202 automatic film processor. Problems due to asymmetry of the bilateral breasts and lack of retroglandular fat tissue space and inframammary folds seen on our initial mammograms were overcome by placing marks at the postion of the AEC sensor, and at both ends and the center of the film on a bucky table. We simplified the markers by removing several complicated ones. We tried to rectify areas of the image that were obscured due to the difference in size between the inside of the cassette and the screen. Physicians and a radiology technician attended a mammography study course once weekly, and attempted to improve the quality of mammograms and our reading ability by obtaining advice from members of the CCQCMS. Manufacturers responded with considerable delay to our attempt to overcome the troublesome appearance of numerous microcalfication-like artifact shadows caused by screens. In conclusion, in order to perform effective breast cancer screening with mammography, we must obtain mammograms of good quality, for which it is necessary to always try to seek new ways of improving. At the same time, manufacturers need to respond quickly to queries and problems related to quality control. (author)

  16. Quality assurance in microbiology

    OpenAIRE

    Arora D

    2004-01-01

    Quality assurance (QA) is the total process whereby the quality of laboratory reports can be guaranteed. The term quality control covers that part of QA, which primarily concerns the control of errors in the performance of tests and verification of test results. All materials, equipment and procedures must be adequately controlled. Culture media must be tested for sterility and performance. Each laboratory must have standard operating procedures (SOPs). QA of pre-analytical, analytical and po...

  17. Cooling water conditioning and quality control for tokamaks

    International Nuclear Information System (INIS)

    Gootgeld, A.M.

    1995-01-01

    Designers and operators of Tokamaks and all associated water cooled, peripheral equipment, are faced with the task of providing and maintaining closed-loop, low conductivity, low impurity, cooling water systems. The primary reason for supplying low conductivity water to the DIII-D vacuum vessel coils, power supplies and auxiliary heating components is to assure, along with the use of a non-conducting break in the supply piping, sufficient electrical resistance and thus an acceptable current-leakage path to ground at operating voltage potentials. As important, good quality cooling water significantly reduces the likelihood of scaling and fouling of flow passages and heat transfer surfaces. Dissolved oxygen gas removal is also required in one major DIII-D cooling water system to minimize corrosion in the ion sources of the neutral beam injectors. Currently, the combined pumping capacity of the high quality cooling water systems at DIII-D is ∼5,000 gpm. Another area that receives close attention at DIII-D is the chemical treatment of the water used in the cooling towers. This paper discusses the DIII-D water quality requirements, the means used to obtain the necessary quality and the instrumentation used for control and monitoring. Costs to mechanically and chemically condition and maintain water quality are discussed as well as the various aspects of complying with government standards and regulations

  18. Daily quality control in computed radiography mammography using the manufacturer phantom

    International Nuclear Information System (INIS)

    Jakubiak, Rosangela R.; Messias, Pricila C.; Oliveira, Carlla M.

    2011-01-01

    The quality control (QC) in mammography system involves a large amount of test tools, which implies a large space for storage and a high number of exposure. This work describes a QC system using a phantom, Fuji Computed Radiography (FCR) One Shot Phantom M Plus, that evaluates several parameters with just one exposure. The software offers tests with annual, semi-annual, quarterly, weekly and daily periodicity, and analyzes the conformities of the mammography equipment, image plate and cassettes. Because of the high number of tests, it was evaluated the daily test only for seven months in two mammography equipment. The test, through the software and its image, allows the analysis of ten parameters in QC. The evaluation of these parameters was realized by the average of the values provided by the software. Only one of the evaluated items showed not conformity, but this was observed and the necessary corrections were realized. The monitoring of use of FCR Mammography QC software with the FCR One Shot Phantom M Plus was realized and through this we could investigate that the quality program provided by the system is appropriate for the radiology services that has the Fuji Computed Radiography system. (author)

  19. The Design and Implementation of the Remote Centralized-Monitoring System of Well-Control Equipment Based on RFID Technique

    Directory of Open Access Journals (Sweden)

    Luo Bin

    2017-01-01

    Full Text Available At present, in domestic for the management of well control equipment continue to the traditional way of nameplates identifies and paper-based registration, there are many issues like the separation of data information of device, easy lose, difficult query, confused management and many other problems, which will make the problem device into the well field, and then resulting in well control runaway drilling accident. To solve the above problems, this paper put forward to the integrated remote centralized-monitoring management mode of the well-control equipment. Taking the advantages of IOT technology, adopting the RFID technology, and combining with the remote transmission, this paper designs the remote centralized-monitoring system of well-control equipment based on RFID, which realizes the intelligent management of well-control equipment and meets the actual demand of the well-control equipment safe use and timely scheduling, and it has the ability of field application.

  20. Autonomous Quality Control of Joint Orientation Measured with Inertial Sensors

    Directory of Open Access Journals (Sweden)

    Karina Lebel

    2016-07-01

    Full Text Available Clinical mobility assessment is traditionally performed in laboratories using complex and expensive equipment. The low accessibility to such equipment, combined with the emerging trend to assess mobility in a free-living environment, creates a need for body-worn sensors (e.g., inertial measurement units—IMUs that are capable of measuring the complexity in motor performance using meaningful measurements, such as joint orientation. However, accuracy of joint orientation estimates using IMUs may be affected by environment, the joint tracked, type of motion performed and velocity. This study investigates a quality control (QC process to assess the quality of orientation data based on features extracted from the raw inertial sensors’ signals. Joint orientation (trunk, hip, knee, ankle of twenty participants was acquired by an optical motion capture system and IMUs during a variety of tasks (sit, sit-to-stand transition, walking, turning performed under varying conditions (speed, environment. An artificial neural network was used to classify good and bad sequences of joint orientation with a sensitivity and a specificity above 83%. This study confirms the possibility to perform QC on IMU joint orientation data based on raw signal features. This innovative QC approach may be of particular interest in a big data context, such as for remote-monitoring of patients’ mobility.

  1. Quality assurance and quality control in mammography: a review of available guidance worldwide.

    Science.gov (United States)

    Reis, Cláudia; Pascoal, Ana; Sakellaris, Taxiarchis; Koutalonis, Manthos

    2013-10-01

    Review available guidance for quality assurance (QA) in mammography and discuss its contribution to harmonise practices worldwide. Literature search was performed on different sources to identify guidance documents for QA in mammography available worldwide in international bodies, healthcare providers, professional/scientific associations. The guidance documents identified were reviewed and a selection was compared for type of guidance (clinical/technical), technology and proposed QA methodologies focusing on dose and image quality (IQ) performance assessment. Fourteen protocols (targeted at conventional and digital mammography) were reviewed. All included recommendations for testing acquisition, processing and display systems associated with mammographic equipment. All guidance reviewed highlighted the importance of dose assessment and testing the Automatic Exposure Control (AEC) system. Recommended tests for assessment of IQ showed variations in the proposed methodologies. Recommended testing focused on assessment of low-contrast detection, spatial resolution and noise. QC of image display is recommended following the American Association of Physicists in Medicine guidelines. The existing QA guidance for mammography is derived from key documents (American College of Radiology and European Union guidelines) and proposes similar tests despite the variations in detail and methodologies. Studies reported on QA data should provide detail on experimental technique to allow robust data comparison. Countries aiming to implement a mammography/QA program may select/prioritise the tests depending on available technology and resources. •An effective QA program should be practical to implement in a clinical setting. •QA should address the various stages of the imaging chain: acquisition, processing and display. •AEC system QC testing is simple to implement and provides information on equipment performance.

  2. Improvement of the quality control program of the clinical dosimeters calibration laboratory of the IPEN/CNEN-SP

    Energy Technology Data Exchange (ETDEWEB)

    Damatto, Willian B.; Potiens, Maria da Penha A.; Vivolo, Vitor, E-mail: wbdamatto@ipen.br, E-mail: mppotiens@ipen.br, E-mail: vivolo@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    A set of clinical dosimeters (thimble ionization chamber coupled to an electrometer) commonly used in radiotherapy in Brazil and sent to the Calibration Laboratory of IPEN were under several tests and analysis parameters for the dosimeters behaviour were established, specifying their sensitivities and operating characteristics. Applied tests were: repeatability, reproducibility and current leakage. Thus it was possible to determine the most common defects found in these equipment and the actions that could be taken to prevent it (clinical dosimeters quality control programs). The behaviour of 167 dosimeters was analyzed and in this study, 62 of them have been tested. The main problem detected during calibration tests was current leakage, i.e. electronic noise. The tests were applied to the routine measurements at the Calibration Laboratory implementing an ideal calibration procedure. New calibration criteria were established following international recommendations. Therefore, it was made the improvement of the quality control programme of the clinical dosimeters calibration laboratory, benefiting the users of such equipment with better consistent calibration measurements. (author)

  3. Improvement of the quality control program of the clinical dosimeters calibration laboratory of the IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Damatto, Willian B.; Potiens, Maria da Penha A.; Vivolo, Vitor

    2013-01-01

    A set of clinical dosimeters (thimble ionization chamber coupled to an electrometer) commonly used in radiotherapy in Brazil and sent to the Calibration Laboratory of IPEN were under several tests and analysis parameters for the dosimeters behaviour were established, specifying their sensitivities and operating characteristics. Applied tests were: repeatability, reproducibility and current leakage. Thus it was possible to determine the most common defects found in these equipment and the actions that could be taken to prevent it (clinical dosimeters quality control programs). The behaviour of 167 dosimeters was analyzed and in this study, 62 of them have been tested. The main problem detected during calibration tests was current leakage, i.e. electronic noise. The tests were applied to the routine measurements at the Calibration Laboratory implementing an ideal calibration procedure. New calibration criteria were established following international recommendations. Therefore, it was made the improvement of the quality control programme of the clinical dosimeters calibration laboratory, benefiting the users of such equipment with better consistent calibration measurements. (author)

  4. Impacts of Water Quality on Residential Water Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Widder, Sarah H.; Baechler, Michael C.

    2013-11-01

    Water heating is a ubiquitous energy use in all residential housing, accounting for 17.7% of residential energy use (EIA 2012). Today, there are many efficient water heating options available for every fuel type, from electric and gas to more unconventional fuel types like propane, solar, and fuel oil. Which water heating option is the best choice for a given household will depend on a number of factors, including average daily hot water use (total gallons per day), hot water draw patterns (close together or spread out), the hot water distribution system (compact or distributed), installation constraints (such as space, electrical service, or venting accommodations) and fuel-type availability and cost. While in general more efficient water heaters are more expensive than conventional water heating technologies, the savings in energy use and, thus, utility bills can recoup the additional upfront investment and make an efficient water heater a good investment over time in most situations, although the specific payback period for a given installation will vary widely. However, the expected lifetime of a water heater in a given installation can dramatically influence the cost effectiveness and savings potential of a water heater and should be considered, along with water use characteristics, fuel availability and cost, and specific home characteristics when selecting the optimum water heating equipment for a particular installation. This report provides recommendations for selecting and maintaining water heating equipment based on local water quality characteristics.

  5. Design and construction of stepper motor controller for brachy-therapy equipment

    International Nuclear Information System (INIS)

    Ahmad Rifai; Usep Setia Gunawan; Indarzah Masbatin Putra

    2011-01-01

    Based on a microcontroller, a stepper motor controller for brachy-therapy equipment has been designed and prototyped. The embedded control program routine and its other associated routines enable the microcontroller to generate required pulses via external commands for stepper motor based position control. The controller receives ASCII text command via a serial port. The constructed algorithm implements the widely used method that allows motor to rotate in three phases, i.e: acceleration, constant speed, and deceleration. (author)

  6. Quality control in breast tomosynthesis; Controle de qualidade em tomossintese mamaria

    Energy Technology Data Exchange (ETDEWEB)

    Jakubiak, Rosangela Requi; Messias, Pricila Cordeiro; Santos, Marilia Fernanda, E-mail: requi@gmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Urban, Linei Augusta B.D., E-mail: ineiurban@hotmail.com [Diagnostico Avancado por Imagem (DAPI), Curitiba, PR (Brazil)

    2014-07-01

    In Brazil breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Breast Digital Tomosynthesis (BDT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared to the mammography. This study presents results of Contrast Ratio Noise tests (CRN) and quality image on a Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CRN was determined with plates Polymethylmethacrylate (PMMA) of 20 to 70 mm thickness and an aluminum plate of 10 mm{sup 2} and 0.2 mm thickness. Image quality was assessed with the ACR Breast Simulator. In assessment of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Were visualized 4.5 fibers and 4 mass in both modes. In 2D mode groups have been identified 3.5 microcalcifications, and 3D were 3 groups. The Mean Glandular Dose for the simulator in 2D mode was 1.17 mGy and 2.35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CRN values, ensuring image quality and dose compatible in 2D and 3D processes.

  7. An open software system based on X Windows for process control and equipment monitoring

    International Nuclear Information System (INIS)

    Aimar, A.; Carlier, E.; Mertens, V.

    1992-01-01

    The construction and application of a configurable open software system for process control and equipment monitoring can speed up and simplify the development and maintenance of equipment specific software as compared to individual solutions. The present paper reports the status of such an approach for the distributed control systems of SPS and LEP beam transfer components, based on X Windows and the OSF/Motif tool kit and applying data modeling and software engineering methods. (author)

  8. Evaluation of mammography equipment performance, dose and image quality in five Latin American countries

    Science.gov (United States)

    Brandan, M.-E.; Ruiz-Trejo, C.; Caspani, C. E. M.; Fleitas, I.; de-la-Mora, R.; Miranda, A. A.; Plazas, M.-C.; Betancourt, C.-M.; Borras, C.

    2001-10-01

    Under the auspices of PAHO/WHO, a multicentric investigation is carried out in five Latin American countries. Its aim is to correlate quality indicators of radiology services with the accuracy of the radiological interpretation as determined by a panel of radiology experts. We present preliminary results from mammographic imaging facilities. Evaluation of the equipment performance and dose measurements in 21 mammographic units show that, on the average, 75% of the units comply with recommendations issued by various organizations. An independent evaluation of the quality of the clinical images show strong variations among the different radiological services.

  9. Evaluation of mammography equipment performance, dose and image quality in five Latin American countries

    International Nuclear Information System (INIS)

    Brandan, M.-E.; Ruiz-Trejo, C.; Caspani, C. E. M.; Fleitas, I.; Mora, R. de la; Miranda, A. A.; Plazas, M.-C.; Betancourt, C.-M.; Borras, C.

    2001-01-01

    Under the auspices of PAHO/WHO, a multicentric investigation is carried out in five Latin American countries. Its aim is to correlate quality indicators of radiology services with the accuracy of the radiological interpretation as determined by a panel of radiology experts. We present preliminary results from mammographic imaging facilities. Evaluation of the equipment performance and dose measurements in 21 mammographic units show that, on the average, 75% of the units comply with recommendations issued by various organizations. An independent evaluation of the quality of the clinical images show strong variations among the different radiological services

  10. [On-site quality control of acupuncture randomized controlled trial: design of content and checklist of quality control based on PICOST].

    Science.gov (United States)

    Li, Hong-Jiao; He, Li-Yun; Liu, Zhi-Shun; Sun, Ya-Nan; Yan, Shi-Yan; Liu, Jia; Zhao, Ye; Liu, Bao-Yan

    2014-02-01

    To effectively guarantee quality of randomized controlld trial (RCT) of acupuncture and develop reasonable content and checklist of on-site quality control, influencing factors on quality of acupuncture RCT are analyzed and scientificity of quality control content and feasibility of on-site manipulation are put into overall consideration. Based on content and checklist of on-site quality control in National 11th Five-Year Plan Project Optimization of Comprehensive Treatment Plan for TCM in Prevention and Treatment of Serious Disease and Clinical Assessment on Generic Technology and Quality Control Research, it is proposed that on-site quality control of acupuncture RCT should be conducted with PICOST (patient, intervention, comparison, out come, site and time) as core, especially on quality control of interveners' skills and outcome assessment of blinding, and checklist of on-site quality control is developed to provide references for undertaking groups of the project.

  11. Design, manufacture and installation of measuring and control equipments for the advanced thermal prototype reactor 'Fugen'

    International Nuclear Information System (INIS)

    Hirota, Shigeo; Kawabata, Yoshinori

    1979-01-01

    The advanced thermal prototype reactor ''Fugen'' attained the criticality on March 20, 1978, and 100% output operation on November 13, 1978. On March 20, 1979, it passed the final inspection, and since then, it has continued the smooth operation up to now. The measuring and control equipments are provided for grasping the operational conditions of the plant and operating it safely and efficiently. At the time of designing, manufacturing and installing the measuring and control equipments for Fugen, it was required to clarify the requirements of the plant design, to secure the sufficient functions, and to improve the operational process, maintainability and the reliability and accuracy of the equipments. Many design guidelines and criteria were decided in order to coordinate the conditions among five manufacturers and give the unified state as one plant. The outline of the instrumentations for neutrons, radiation monitoring and process data, the control systems for reactivity, reactor output, pressure and water supply, the safety protection system, and the process computer are described. Finally, the installations and tests of the measuring and control equipments are explained. The aseismatic capability of the equipments was confirmed. (Kako, I.)

  12. Current State Park General Radiology in the region of Murcia. 18 years of quality control; Estado actual del Parque de Radiologia General de la region de Murcia. 18 anos de controles de calidad

    Energy Technology Data Exchange (ETDEWEB)

    Vera Sanchez, J. A.; Buades Forner, M. J.; Tobarra Gonzalez, B. M.

    2011-07-01

    This paper examines the latest campaign for quality control of technical parameters of equipment carried out by l Radiological Protection Service of the Hospital Universitario Virgen de la Arrixaca, and compare the present results with those presented by this same service Congress of the Spanish Society of Medical Physics in 1993. [1], corresponding to the first quality control campaign conducted in 1992. (Author) 2 refs.

  13. Application of owner technical management in hydraulic machinery and electrical equipment investment target control

    International Nuclear Information System (INIS)

    Luo, H

    2012-01-01

    Using technical means in investment target control is an effective method to improve investment benefit of a construction project. Take the practice of construction and management in hydropower station as an example, the investment and management need of the owner is put forward through the investment target decision-making process of electromechanical equipment. Owner technical management in the specific application measures and effects of investment target control was discussed in the paper, and the revelation in investment target control application of owner technical management was also summarized. The paper is aimed to provide a useful reference for the investment target control work in the construction of electromechanical equipment.

  14. SPS/LEP beam transfer equipment control using industrial automation components

    International Nuclear Information System (INIS)

    Aimar, A.; Berard, G.; Bretin, J.L.; Carlier, E.; Dieperink, J.H.; Laffin, M.; Mertens, V.; Verhagen, H.

    1992-01-01

    Several control systems for SPS and LEP beam transfer equipment have to be commissioned in the near future. Tools for fast software development, easy maintenance and modifications, compliance with industrial standards, and independence of specific suppliers are considered to be essential. A large fraction of the systems can be realized using off-the-shelf industrial automation components like industrial I/O systems, programmable logic controllers, or diskless PCs. Specific electronics built up in G-64 can be integrated. Diskless systems running UNIX and X Windows are foreseen as process controllers and local access media. (author)

  15. An approach to quality and performance control in a computer-assisted clinical chemistry laboratory.

    Science.gov (United States)

    Undrill, P E; Frazer, S C

    1979-01-01

    A locally developed, computer-based clinical chemistry laboratory system has been in operation since 1970. This utilises a Digital Equipment Co Ltd PDP 12 and an interconnected PDP 8/F computer. Details are presented of the performance and quality control techniques incorporated into the system. Laboratory performance is assessed through analysis of results from fixed-level control sera as well as from cumulative sum methods. At a simple level the presentation may be considered purely indicative, while at a more sophisticated level statistical concepts have been introduced to aid the laboratory controller in decision-making processes. PMID:438340

  16. Organization of a system of guarantee of quality for the control of specifications of chemical reagents

    International Nuclear Information System (INIS)

    Bustamante Gutierrez, M. G.

    2000-01-01

    Analytic methods were implemented based on valuations acid-base and redox for the quantitative determination of sodium hidroxid, iodine and iron chloride III, like part of a system of quality for the technical specifications of these reagents. The planning of its system of quality includes two fundamental parts: insurance and control of quality. In the insurance part the state of operation of the team that you uses settled down, gauges the one that achieve to maintain under the supervision of a single operator (electronic equip and glassware) and the design of the appropriate documents settled down to carry out the periodic supervision of the acting of the same ones and other aspects characteristic of the system (experimental results). Also protocolized and validated the analytic methods to use following the approaches of precision given by ASTM, organism whose methodologies are recognized in the country like official; other procedures, as that of calibration of the volumetric equipments, they were also protocolized. In the part of control of quality, the limits settled down and procedures were applied the scales and used other, to the necessary distilled water to carry out the determinations and to the used chemical reagents. With base in the obtained results you determines that the analyzed reagents fulfill the specifications of ACS (and with those reported by the maker) at the same time settled down that the laboratory 09 of the Chemistry School, used in a large part of development of this project, it didn't fulfill the necessary requirements so that it works as laboratory of control of quality. As an alternative, the administration of the School outlines as solution the use of the Laboratory of Insurance of the Quality from the Unit of Service to the Industry for such end [es

  17. A Method of Numerical Control Equipment Appearance Design Based on Product Identity

    Science.gov (United States)

    Zhu, Zhijuan; Zhou, Qi; Li, Bin; Visser, Steve

    Research on numerical control (NC) equipment has been more and more abundant; however, there are few existing studies in the field of appearance design for NC equipments. This paper provided a method to generate new appearance design of NC equipments based on product identity (PI). For the purpose of providing guidelines to generate new concept of NC equipment design, this paper, therefore, took the DMG Company (a Germen NC equipment company) as a case, examined the total products of this company from two aspects: Product Image and Product Family. Task 1 was an evaluate task about the Product Image by using the semantic differential (SD) evaluation method; Task 2 was a study task about Product Family to find out features of the products and classify these features. During the Task 2, several features have been found out and summarized, and these features were classified into 3 different levels according to their frequency and importance. In the end, two appearance design samples have been generated based on the analysis above to prove the application of the research.

  18. Software product quality control

    CERN Document Server

    Wagner, Stefan

    2013-01-01

    Quality is not a fixed or universal property of software; it depends on the context and goals of its stakeholders. Hence, when you want to develop a high-quality software system, the first step must be a clear and precise specification of quality. Yet even if you get it right and complete, you can be sure that it will become invalid over time. So the only solution is continuous quality control: the steady and explicit evaluation of a product's properties with respect to its updated quality goals.This book guides you in setting up and running continuous quality control in your environment. Star

  19. 46 CFR 180.175 - Survival craft equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Survival craft equipment. 180.175 Section 180.175... TONS) LIFESAVING EQUIPMENT AND ARRANGEMENTS Survival Craft Arrangements and Equipment § 180.175 Survival craft equipment. (a) General. Each item of survival craft equipment must be of good quality, and...

  20. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Kaden, W.

    1986-01-01

    General preconditions and methods for QA work in the nuclear field are analysed. The application of general QA principles to actual situations is illustrated by examples in the fields of engineering and of the manufacturing of mechanical and electrical components. All QA measures must be fitted to the complexity and relevance of the work steps, which are under consideration. The key to good product quality is the control of working processes. The term 'controlled process' is discussed in detail and examples of feed back systems are given. The main QA measures for the operation of nuclear power plants include the establishment of a Quality Assurance Program, training and qualification of personnel, procurement control, inspection and tests, reviews and audits. These activities are discussed. (orig.)

  1. Data center equipment location and monitoring system

    DEFF Research Database (Denmark)

    2011-01-01

    A data center equipment location system includes both hardware and software to provide for location, monitoring, security and identification of servers and other equipment in equipment racks. The system provides a wired alternative to the wireless RFID tag system by using electronic ID tags...... connected to each piece of equipment, each electronic ID tag connected directly by wires to a equipment rack controller on the equipment rack. The equipment rack controllers then link over a local area network to a central control computer. The central control computer provides an operator interface......, and runs a software application program that communicates with the equipment rack controllers. The software application program of the central control computer stores IDs of the equipment rack controllers and each of its connected electronic ID tags in a database.; The software application program...

  2. Quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Leme, P.R.

    1983-01-01

    The following topics are discussed: objectives of the quality control in nuclear medicine; the necessity of the quality control in nuclear medicine; guidelines and recommendations. An appendix is given concerning the guidelines for the quality control and instrumentation in nuclear medicine. (M.A.) [pt

  3. Quality of care and investment in property, plant, and equipment in hospitals.

    Science.gov (United States)

    Levitt, S W

    1994-01-01

    OBJECTIVE. This study explores the relationship between quality of care and investment in property, plant, and equipment (PPE) in hospitals. DATA SOURCES. Hospitals' investment in PPE was derived from audited financial statements for the fiscal years 1984-1989. Peer Review Organization (PRO) Generic Quality Screen (GQS) reviews and confirmed failures between April 1989 and September 1990 were obtained from the Massachusetts PRO. STUDY DESIGN. Weighted least squares regression models used PRO GQS confirmed failure rates as the dependent variable, and investment in PPE as the key explanatory variable. DATA EXTRACTION. Investment in PPE was standardized, summed by the hospital over the six years, and divided by the hospital's average number of beds in that period. The number of PRO reviewed cases with one or more GQS confirmed failures was divided by the total number of cases reviewed to create confirmed failure rates. PRINCIPAL FINDINGS. Investment in PPE in Massachusetts hospitals is correlated with GQS confirmed failure rates. CONCLUSIONS. A financial variable, investment in PPE, predicts certain dimensions of quality of care in hospitals. PMID:8113054

  4. Development of a dosimetric system for dental X-ray equipment quality control; Desenvolvimento de um sistema dosimetrico para controle de qualidade de equipamentos de raios-X odontologicos

    Energy Technology Data Exchange (ETDEWEB)

    Melo, Francisco Almeida de

    2002-08-01

    An electronic instrument with digital readout was designed and constructed to provide fast, simple and non-invasive measurements of X-ray dental equipment parameters. This instrument is capable of evaluating the entrance dose, exposure time, tube voltage (kVp) and beam filtration. It consists of a set of five photodiodes connected each one in the photocurrent mode to the input of a designed integrating electrometer. Three of the detectors are fixed under aluminium filters with different thicknesses, one is fixed under a 0.3 mm copper filter and the other has no filtration. The readings of the three detectors under aluminium filters and of the bare detector permit the determination of the half-value layer, which is used to calculate the beam filtration. The ratio between the readings of the detector below the copper filter and the one without filtration is used to determine the tube voltage. The signal produced by the detector without filter is used to evaluate the patient entrance dose, and to active an electronic timer for measuring the real exposure time. The tests and calibration of the instrument in different voltages in the 59 - 70kVp range, showed that its response is both stable and reproducible to within 1%. The instrument response was compared to the one from a commercial non-invasive X-ray test equipment (Gammex RMI Multifunction kVp meter). The results showed that the response of the developed instrument is in good agreement with the RMI meter which is the standard equipment for such measurements. These results indicate that the dosimetric system is suitable for use in Dental Quality Assurance Programs. (author)

  5. 47 CFR 90.475 - Operation of internal transmitter control systems in specially equipped systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Operation of internal transmitter control... Control Internal Transmitter Control Systems § 90.475 Operation of internal transmitter control systems in specially equipped systems. (a) An internal transmitter control system need not be designed to meet the...

  6. Power quality control of an autonomous wind-diesel power system based on hybrid intelligent controller.

    Science.gov (United States)

    Ko, Hee-Sang; Lee, Kwang Y; Kang, Min-Jae; Kim, Ho-Chan

    2008-12-01

    Wind power generation is gaining popularity as the power industry in the world is moving toward more liberalized trade of energy along with public concerns of more environmentally friendly mode of electricity generation. The weakness of wind power generation is its dependence on nature-the power output varies in quite a wide range due to the change of wind speed, which is difficult to model and predict. The excess fluctuation of power output and voltages can influence negatively the quality of electricity in the distribution system connected to the wind power generation plant. In this paper, the authors propose an intelligent adaptive system to control the output of a wind power generation plant to maintain the quality of electricity in the distribution system. The target wind generator is a cost-effective induction generator, while the plant is equipped with a small capacity energy storage based on conventional batteries, heater load for co-generation and braking, and a voltage smoothing device such as a static Var compensator (SVC). Fuzzy logic controller provides a flexible controller covering a wide range of energy/voltage compensation. A neural network inverse model is designed to provide compensating control amount for a system. The system can be optimized to cope with the fluctuating market-based electricity price conditions to lower the cost of electricity consumption or to maximize the power sales opportunities from the wind generation plant.

  7. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Science.gov (United States)

    2010-07-01

    ... quality assurance audit or any other audit, the system is out-of-control. The owner or operator shall... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...

  8. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Kristensen, K.

    1981-01-01

    Quality assurance was introduced in the pharmaceutical field long before it was used in many other areas, and the term quality control has been used in a much broader sense than merely analytical quality control. The term Good Manufacturing Practice (GMP) has been used to describe the system used for producing safe and effective drugs of a uniform quality. GMP has also been used for the industrial production of radiopharmaceuticals. For the preparation and control of radiopharmaceuticals in hospitals a similar system has been named Good Radiopharmacy Practice (GRP). It contains the same elements as GMP but takes into account the special nature of this group of drugs. Data on the assessment of the quality of radiopharmaceuticals in relation to present standards are reviewed. The general conclusion is that the quality of radiopharmaceuticals appears comparable to that of other drugs. It seems possible to establish the production of radiopharmaceuticals, generators and preparation kits in such a way that analytical control of the final product at the hospital may be limited provided the final preparation work is carried out in accordance with GRP principles. The elements of GRP are reviewed. (author)

  9. Development of special ionization chambers for a quality control program in mammography; Desenvolvimento de camaras de ionizacao especiais para controle de qualidade em mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Jonas Oliveira da

    2013-07-01

    Mammography is an imaging method that uses X-rays. The use of ionization chambers in mammography quality control programs presents an essential role which is to verify whether the parameters of the patient exposure are correct. However, the commercial ionization chambers for dosimetry in mammography represent a high cost for small and medium size clinics that wish to have this equipment or for professionals that work with quality control programs. The innovative feature of this work was to develop ionization chambers for this purpose. In this work ionization chambers for X radiation beams in the mammography energy range were designed, constructed and characterized. The ionization chambers were tested in standard X radiation beams at the LCI/IPEN. The main characterization tests performed with the ionization chambers were: saturation curve, linearity of response, angular and energy dependence. The response stability tests of the ionization chambers were also conducted at the LCI, presenting results within 2.0 % for long-term stability. The results of the remaining tests are in accordance with international standards. These ionization chambers were also submitted to quality control tests of mammography equipment: linearity of the air kerma rates, determination of half-value layers and mean glandular doses. The results for air kerma rate linearity were less than 10 %, as recommended in international standards. The mean glandular dose obtained with the developed chambers presented values comparable to those of commercial ionization chambers tested, with an estimated variation within international standards. (author)

  10. SPECT quality control tests

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.; Abe, R.

    1987-01-01

    Quality control tests of tomographic system composed by a rotatory chamber (CGR Gammatomome T-9000) and a microcomputer are presented. Traditional quality control tests for scintilation chambers and specific tests for tomographic systems are reported. (M.A.C.) [pt

  11. Project management in nuclear equipment manufacture

    International Nuclear Information System (INIS)

    Liu Jiancheng

    2005-01-01

    The completion of the management organization shall be firstly considered in project management for a nuclear power plant. The organization of nuclear equipment quality assurance program and project management consists of 5 departments such as the nuclear power container department, the manufacture department and the quality assurance department. The general manager takes the overall responsibility for the quality of the nuclear press usr bearing equipment, and the vice general manager takes responsibility for the quality, technology and schedule related with the manufacture of the equipment, and organizes the organization department for the audit. The director of the quality assurance department takes the responsibility for the establishment and completion of the quality assurance program, with enough rights authorized by the general manager, including the right not bounded by the cost and schedule, and confirms the implementation of the program by related departments and personnel. The manufacture schedule shall be prepared to ensure the implementation feasibility, process continuity and flexibility. The schedule shall be followed and monitored for the whole process, to check and feedback the implementation. (authors)

  12. Operating the plant, quality assurance, and the job of the operating staff, Volume Twelve

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Subject matter includes operating the plant (the role of the operator, the control room, plant technical specifications, plant operating procedures, initial startup program, BWR/PWR plant startup, BWR/PWR steady state power operation, BWR/PWR transient operation, emergency operation), quality assurance (what is quality, what is quality control, quality assurance includes quality control, government regulation and quality assurance, administrative controls for nuclear power plants, the necessity of reviews and audits, practical quality assurance), and the job of the operating staff (the plant operating staff, plant safety, first aid and resuscitation, general plant hazards, personnel protective equipment, handling chemicals, handling compressed gas, equipment repair and maintenance, communicating with others

  13. Quality assurance and quality control of nuclear engineering during construction phase

    International Nuclear Information System (INIS)

    Zhang Zhihua; Deng Yue; Liu Yaoguang; Xu Xianqi; Zhou Shan; Qian Dazhi; Zhang Yang

    2007-01-01

    The quality assurance (QA) and quality control (QC) is a very important work in the nuclear engineering. This paper starts with how to establish quality assurance system of nuclear engineering construction phase, then introduces several experiments and techniques such as the implementation of quality assurance program, the quality assurance and quality control of contractors, the quality surveillance and control of supervisory companies, quality assurance audit and surveillance of builders. (authors)

  14. Quality stabilisation of synthetic sand containing bentonite in process lines

    OpenAIRE

    A. Fedoryszyn

    2010-01-01

    Stabilisation of sand quality requires the monitoring and control of sand moisture contents and its other parameters at each stage of sandprocessing, i.e. during the preparation of return sand mix and rebonding processes. Stabilisation of sand quality necessitates the use of reliable control equipment and evaluation procedures. This study outlines the scope and results of research work aimed to improve the control equipment to enhance the performance of turbine mixers. The paper reviews the m...

  15. Performance of the standard FAIR equipment controller prototype

    International Nuclear Information System (INIS)

    Rauch, S.; Baer, R.C.; Panschow, W.; Thieme, M.

    2012-01-01

    For the control system of the new FAIR accelerator facility a standard equipment controller, the Scalable Control Unit (SCU), is presently under development. First prototypes have already been tested in real applications. The controller combines an *86 COM Express TM Board and an Altera Arria TM II FPGA. Over a parallel bus interface called the SCU bus, up to 12 slave boards can be controlled. Communication between CPU and FPGA is done by a PCIe link. We discuss the real time behaviour between the Linux OS and the FPGA Hardware. For the test, a Front-End Software Architecture (FESA) class, running under Linux, communicates with the PCIe bridge in the FPGA. Although we are using PCIe only for single 32 bit wide accesses to the FPGA address space, the performance still seems sufficient. The tests showed an average response time to IRQs of 50 μs with a 1.6 GHz Intel Atom CPU. This includes the context change to the FESA user space application and the reply back to the FPGA. Further topics are the bandwidth of the PCIe link for single/burst transfers and the performance of the SCU bus communication. (authors)

  16. Protocol for the quality control systems of electronic portal imaging used in verification of radiotherapy treatment

    International Nuclear Information System (INIS)

    Silvestre, Ileana; Alfonso, Rodolfo; Garcia, Fernando

    2009-01-01

    Following the approach of quality control of radiotherapy equipment, conceived in the IAEA TECDOC-1151, we analyzed the different tests must be to an EPID to guarantee levels of accuracy required in the administration of radiation treatments, including the study of the impact of different parameters, geometric and dosimetric imaging, involved in the process. Established the types and frequency of checks, as well as procedures for their implementation, the allowable tolerances set of values records and forms for recording . Was carried out assessment protocol in various services based on amorphous silicon EPID for its applicability and scope. Was designed and validated in clinical practice protocol for EPID quality control, demonstrating its applicability with a minimum of material and human resources. It We concluded that with proper and systematic quality control program, tests including dosimetry, the EPID can provide valuable information about physico-beam dosimetry, and ensure adequate accuracy geometric in the patient's location. (author)

  17. 46 CFR 117.175 - Survival craft equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Survival craft equipment. 117.175 Section 117.175... AND ARRANGEMENTS Survival Craft Arrangements and Equipment § 117.175 Survival craft equipment. (a) General. Each item of survival craft equipment must be of good quality, and efficient for the purpose it...

  18. Tracking reliability for space cabin-borne equipment in development by Crow model.

    Science.gov (United States)

    Chen, J D; Jiao, S J; Sun, H L

    2001-12-01

    Objective. To study and track the reliability growth of manned spaceflight cabin-borne equipment in the course of its development. Method. A new technique of reliability growth estimation and prediction, which is composed of the Crow model and test data conversion (TDC) method was used. Result. The estimation and prediction value of the reliability growth conformed to its expectations. Conclusion. The method could dynamically estimate and predict the reliability of the equipment by making full use of various test information in the course of its development. It offered not only a possibility of tracking the equipment reliability growth, but also the reference for quality control in manned spaceflight cabin-borne equipment design and development process.

  19. Evaluation of Quality-Assurance/Quality-Control Data Collected by the U.S. Geological Survey from Wells and Springs between the Southern Boundary of the Idaho National Engineering and Environmental Laboratory and the Hagerman Area, Idaho, 1989 through 1995

    Energy Technology Data Exchange (ETDEWEB)

    Williams, L.M.; Bartholomay, R.C.; Campbell, L.J.

    1998-10-01

    The U.S. Geological (USGS) and the Idaho Department of Water Resources, in cooperation with the U.S. Department of Energy, collected and analyzed water samples to monitor the water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering and Environmental Laboratory to the Hagerman area, Idaho. Concurrently, replicate samples and blank samples were collected and analyzed as part of the quality-assurance/quality-control program. Samples were analyzed from inorganic constituents, gross radioactivity and radionuclides, organic constituents, and stable isotopes. To evaluate the precision of field and laboratory methods, analytical results of the water-quality and replicate samples were compared statistically for equivalence on the basis of the precision associated with each result. Statistical comparisons of the data indicated that 95 percent of the results of the replicate pairs were equivalent. Blank-sample analytical results indicated th at the inorganic blank water and volatile organic compound blank water from the USGS National Water Quality Laboratory and the distilled water from the Idaho Department of Water Resources were suitable for blanks; blank water from other sources was not. Equipment-blank analytical results were evaluated to determine if a bias had been introduced and possible sources of bias. Most equipment blanks were analyzed for trace elements and volatile organic compounds; chloroform was found in one equipment blank. Two of the equipment blanks were prepared after collection and analyses of the water-quality samples to determine whether contamination had been introduced during the sampling process. Results of one blank indicated that a hose used to divert water away from pumps and electrical equipment had contaminated the samples with some volatile organic compounds. Results of the other equipment blank, from the apparatus used to filter dissolved organic carbon samples, indicated that the filtering

  20. Evaluation of a Trapezoidal Predictive Controller for a Four-Wire Active Power Filter for Utility Equipment of Metro Railway, Power-Land Substations

    Directory of Open Access Journals (Sweden)

    Sergio Salas-Duarte

    2016-01-01

    Full Text Available The realization of an improved predictive current controller based on a trapezoidal model is described, and the impact of this technique is assessed on the performance of a 2 kW, 21.6 kHz, four-wire, Active Power Filter for utility equipment of Metro Railway, Power-Land Substations. The operation of the trapezoidal predictive current controller is contrasted with that of a typical predictive control technique, based on a single Euler approximation, which has demonstrated generation of high-quality line currents, each using a 400 V DC link to improve the power quality of an unbalanced nonlinear load of Metro Railway. The results show that the supply current waveforms become virtually sinusoidal waves, reducing the current ripple by 50% and improving its power factor from 0.8 to 0.989 when the active filter is operated with a 1.6 kW load. The principle of operation of the trapezoidal predictive controller is analysed together with a description of its practical development, showing experimental results obtained with a 2 kW prototype.

  1. Data Center Equipment Location and Monitoring System

    DEFF Research Database (Denmark)

    2013-01-01

    Abstract: Data center equipment location systems include hardware and software to provide information on the location, monitoring, and security of servers and other equipment in equipment racks. The systems provide a wired alternative to the wireless RFID tag system by using electronic ID tags...... connected to each piece of equipment, each electronic ID tag connected directly by wires to an equipment rack controller on the equipment rack. The equipment rack controllers link to a central control computer that provides an operator ...

  2. Development of controller strategies for a robotized filament winding equipment

    Science.gov (United States)

    Lobo, Edgar; Machado, José; Mendonça, João P.

    2013-10-01

    The composites reinforced with continuous fibers of polymeric material are increasingly used in applications where it is essential to reduce weight, mainly due to their high ratio of strength/weight and rigidity/weight. A conventional application are pressure vessels, used for storing liquids or gases subjected to low or high pressure, where the tape continuous fiber-reinforced polymeric matrix material is wound around a mandrel defining the final geometry. In this context the filament winding process is a very attractive process for the production of composite components. For optimal structural performance, and greater weight saving, an optimal path should be adopted, resulting only in axial tension in the longitudinal direction (slip). Such path is the geodesic winding and diverse equipment may be used to guarantee the process automation of the winding. This work herein presented is focused on the study and development of the controller program for a robotized filament winding equipment, taking into account customization of possible trajectories controlling filament winding. The automation of the custom path according to user needs increases exponentially the capabilities, where the use of a robotized solution increases process flexibility and repeatability.

  3. Development of a plug in for image j for the quality control of a scanner; Desarrollo de un Plug-in de Imagej para el control de calidad de un escaner

    Energy Technology Data Exchange (ETDEWEB)

    Otal Palacin, A.; Fuentemilla Urio, N.; Olasolo Alonso, J.; Martin Albina, M. L.; Miquelez Alonso, S.; Lozares Cordero, S.; Pellejero, S.; Maneru Camara, F.; Rubio Arroniz, A.; Soto Prados, P.

    2013-07-01

    The increase in the quality of radiology equipment requirements necessitates that give us tools efficient that they simplify the more possible tasks of analysis of the data obtained in the quality controls. We can choose by solutions based on commercial software or otherwise try to develop our own to measure of our needs. For this reason we have developed a plug-in for the ImageJ program that automates the work of analysis of image quality in the Navarro health service scanners. (Author)

  4. Valorization procedure of x-ray equipment in the mammography equipment

    International Nuclear Information System (INIS)

    Ruiz, M. A.; Ordonez, J.; Antolin, E.; Andres, J. C. de; Gonzalez, I.; Arranz, L.; Sastre, J. M.; Ferrer, N.

    2006-01-01

    The Ramon y Cajal Hospital mammography service has three X-rays units, two of them with high resolution computed radiography (CR) system and one with flat-panel (FP)-based full-field digital mammography system. Periodic control dose tests in patients have shown lower glandular dose levels (DGM) than references provided by European Protocol for de Quality Control of de Physical and Technical Aspects of Mammography Screening. In this work, we have tried to establish an easy method for DGM calculation which is representative of the three equipment results. For this aim, we have defined an index which is measured along the time like a reference point. This index is defined as the relation between the blind test punctuations of a standard phantom image given by at least three radiologists in the Unit, and the average DGM values obtained in 20 patients in each Unit (using random thickness and random mama composition). (Author)

  5. Financing of power supply systems and pollution control equipment. Models, dimensions, developments

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, G; Raabe, G

    1988-11-01

    The authors explain the bankers' point of view of the financial and economic aspects of developments in the energy sector, discussing the financing of natural gas pipelines (Muro, Megal, etc.), of nuclear power plant construction, of projects in the oil supply sector, and of pollution abatement measures and equipment for the power industry and other industries. The different financial situations of small firms or large firms supplying pollution control equipment are discussed referring to the financing schemes to be set up, explaining among other things the profitability assessment taking into account long-term development or delays in return on capital investment from borrowed funds as induced, e.g., by delays in the licensing procedure. Future demand for borrowed capital for pollution control or nuclear power plant development is difficult to assess by the banking circles. (orig./RST).

  6. Radiotherapy equipment for conformal radiotherapy and IMRT in the Czech Republic

    International Nuclear Information System (INIS)

    Horakova, I.; Irena Pavlikova, I.; Novotny, J. ml.

    2005-01-01

    The development of the equipment of radiotherapy departments in the Czech Republic is presented here. The data from the special questionnaire from 14 workplaces with linear accelerators with multi-leaf collimators (MLC) and electronic portal imaging device (EPID) are included. They show not only the equipment specification but also the application methods, the quality control, plans for future etc. In the Czech Republic, a great extension of modem irradiation techniques and accessories occurs at present. Together with it, it is necessary to develop quality assurance of the whole process of dose delivery to the patient. It is also necessary to assure further education and training of hospital staff. Modern radiotherapy techniques demand sufficient amount of all sources including personal sources. (authors)

  7. Quality control in the commerce of irradiated foods; Control de calidad en el comercio de alimentos irradiados

    Energy Technology Data Exchange (ETDEWEB)

    Bustos R, M.E. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    In spite of an irradiated food is innocuous for health and that the irradiation process offers great advantages as conservation and hygiene method and it has been recognised by the Agriculture and Health International organizations and although the adequate equipment exists to make this treatment in the majority of countries, an international trade of irradiated foods has not been established and it is that it has to be required that the quality control of the treatment should be regulated by the corresponding authorities and it also should be harmonized with other countries for the commercial interchange. Owing to up to present an identification method of irradiated foods which is validated, the unique quality control for irradiated foods is realized in the irradiation plant, measuring the absorbed dose in products, using dosimetric systems justly calibrated and standardized to be used the adequate for the type of product and dose level which is wanted to be measured for foods mainly for quarantine treatment which is very important to determine that any part of the irradiation system has reached the minimum dose to obtain the technical effect which is desired and that it does not exceed the maximum dose for that the product quality not to be altered. (Author)

  8. Development of nuclear power plant online monitoring system using statistical quality control

    International Nuclear Information System (INIS)

    An, Sang Ha

    2006-02-01

    Statistical Quality Control techniques have been applied to many aspects of industrial engineering. An application to nuclear power plant maintenance and control is also presented that can greatly improve plant safety. As a demonstration of such an approach, a specific system is analyzed: the reactor coolant pumps (RCP) and the fouling resistance of heat exchanger. This research uses Shewart X-bar, R charts, Cumulative Sum charts (CUSUM), and Sequential Probability Ratio Test (SPRT) to analyze the process for the state of statistical control. And we made Control Chart Analyzer (CCA) to support these analyses that can make a decision of error in process. The analysis shows that statistical process control methods can be applied as an early warning system capable of identifying significant equipment problems well in advance of traditional control room alarm indicators. Such a system would provide operators with enough time to respond to possible emergency situations and thus improve plant safety and reliability

  9. Irradiation position-control equipment for the HIMAC

    Energy Technology Data Exchange (ETDEWEB)

    Higashi, Seiichi; Kuma, Shoichiro [Mitsubishi Electric Corp., Tokyo (Japan); Nomura, Kazuaki; Endo, Masahiro; Minohara, Shin-ichi

    1995-02-01

    Use of heavy-ion beams to mount a pinpoint attack on unhealthy tissue requires that the target tissue be placed in the precise location specified by the therapy planning equipment. The article reports on the detailed specifications, positioning mechanism, position verification method and the interface with the therapy planning equipment. (author).

  10. Safety management of software-based equipment

    CERN Document Server

    Boulanger, Jean-Louis

    2013-01-01

    A review of the principles of the safety of software-based equipment, this book begins by presenting the definition principles of safety objectives. It then moves on to show how it is possible to define a safety architecture (including redundancy, diversification, error-detection techniques) on the basis of safety objectives and how to identify objectives related to software programs. From software objectives, the authors present the different safety techniques (fault detection, redundancy and quality control). "Certifiable system" aspects are taken into account throughout the book. C

  11. Guidelines for the design of the working rules of the guarantee and quality control in radiotherapy commission

    International Nuclear Information System (INIS)

    Pardo, J.; Galmes, M.A.; Font, J.; Caro, J.; Serra, J.; Mata, F.; Bertan, S.; Biete, A.; Carceller, J.A.; Esco, R.; Palacios, A.; Veiras, C.; Vazquez, M.G.

    2001-01-01

    The 1566/1988 Royal Decree stated on July 17 th , focused on Quality Criteria in Radiation Therapy, was published in the Official Spanish Gazette on August 28 th . Its publication began a self-analysis process in all the Spanish Radiation Oncology Departments due to the fact that it implies the guidelines elaboration of each step of the radiation therapy process, including the patient post-treatment follow up and the equipment quality control. The Royal Decree orders the managers of the hospitals and facilities that have a radiation oncology department to create the Guarantee and Quality Control in Radiotherapy Commission. According to the Spanish law regulations, every single commission must have its own working rules based on the Chapter II, focused in 'Organos Colegiados', of the 30/1992 Law stated on November 27 th about Public Administration Legal Rules. The Guidelines for the design of the Guarantee and Quality Control in Radiotherapy Commission Working Rules here presented, have been done by consensus in Son Dureta University Hospital and afterwards sent to all Radiation Oncology Departments by the Spanish Society for Radiotherapy and Oncology. (author)

  12. Evaluation of safety requirements of erbium laser equipment used in dentistry

    International Nuclear Information System (INIS)

    Braga, Flavio Hamilton

    2002-01-01

    The erbium laser (Er:YAG) has been used in several therapeutic processes. Erbium lasers, however, operate with energies capable to produce lesions in biological tissues. Aiming the safe use, the commercialization of therapeutic laser equipment is controlled in Brazil, where the equipment should comply with quality and safety requirement prescribed in technical regulations. The objective of this work is to evaluate the quality and safety requirements of a commercial therapeutic erbium laser according to Brazilian regulations, and to discuss a risk control program intended to minimize the accidental exposition at dangerous laser radiation levels. It was verified that the analyzed laser can produce lesions in the skin and eyes, when exposed to laser radiation at distances smaller than 80 cm by 10 s or more. In these conditions, the use of protection glasses is recommended to the personnel that have access to the laser operation ambient. It was verified that the user's training and the presence of a target indicator are fundamental to avoid damages in the skin and buccal cavity. It was also verified that the knowledge and the correct use of the equipment safety devices, and the application of technical and administrative measures is efficient to minimize the risk of dangerous expositions to the laser radiation. (author)

  13. Implementation of Quality Control Protocol in Mammography: A Serbian Experience

    International Nuclear Information System (INIS)

    Ciraj Bjelac, O.; Kosutic, D.; Arandjic, D.; Kovacevic, M.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. In Serbia, mammography is performed only clinically, although there is a long term plan to introduce mammography as screening method. Currently there are 60 mammography units in practice in Serbia, resulting with 70 000 mammographies annually. The purpose of this paper is preliminary evaluation of the mammography practice in Serbia, having in mind the annual number of examinations and fact that part of examination is performed on women without any clinical signs. For pilot implementation of Quality Control (QC) protocol in mammography, five hospitals with highest workload have been selected, representing the typical mammography practice in Serbia. Developed QC protocol, based on European guidelines for quality assurance in breast cancer screening and diagnosis, actual practice and resources, includes equipment testing and maintenance, staff training and QC management and allocation of responsibilities. Subsequently, it should be applied on the national scale. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Main problems were associated with film processing, viewing conditions and optical density control. The preliminary survey of mammography practice highlighted the need for optimization of radiation protection and training of operating staff, although the survey itself was very valuable learning process for all participants. Furthermore, systematic implementation of QC protocol should provide reliable performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practical.(author)

  14. Data acquisition, remote control and equipment monitoring for ISOLDE RILIS

    Science.gov (United States)

    Rossel, R. E.; Fedosseev, V. N.; Marsh, B. A.; Richter, D.; Rothe, S.; Wendt, K. D. A.

    2013-12-01

    With a steadily increasing on-line operation time up to a record 3000 h in the year 2012, the Resonance Ionization Laser Ion Source (RILIS) is one of the key components of the ISOLDE on-line isotope user facility at CERN. Ion beam production using the RILIS is essential for many experiments due to the unmatched combination of ionization efficiency and selectivity. To meet the reliability requirements the RILIS is currently operated in shift duty for continuous maintenance of crucial laser parameters such as wavelength, power, beam position and timing, as well as ensuring swift intervention in case of an equipment malfunction. A recent overhaul of the RILIS included the installation of new pump lasers, commercial dye lasers and a complementary, fully solid-state titanium:sapphire laser system. The framework of the upgrade also required the setup of a network-extended, LabVIEW-based system for data acquisition, remote control and equipment monitoring, to support RILIS operators as well as ISOLDE users. The system contributes to four key aspects of RILIS operation: equipment monitoring, machine protection, automated self-reliance, and collaborative data acquisition. The overall concept, technologies used, implementation status and recent applications during the 2012 on-line operation period will be presented along with a summary of future developments.

  15. Establishment for Nuclear Equipment -Overview

    International Nuclear Information System (INIS)

    Pracz, J.

    2006-01-01

    Research and development works conducted in the Establishment for Nuclear Equipment (ZdAJ) were focused around 3 subject areas: an accelerator for cancer treatment, therapeutical tables, systems and methods for controlling objects that cross international borders. The new, medium energy accelerator for cancer therapy cases is being designed in the Establishment for several years. In 2005 progress was achieved. A physical part, containing an electron beam has been completed and the parameters of that beam make it useful for therapeutical purposes. Consequently, the work on designing and testing of beam control systems, ensuring its high stability, repetition of irradiation parameters and accuracy of dosage have been started. Results of these tests make it very probable that 2006 will be the final year of scientific works and in 2007 the new apparatus will be ready for sales. Therapeutical tables have become a leading product of ZdAJ IPJ. Their technical parameters, reliability and universality in uses are appreciated by many customers of ZdAJ. In 2005, the table Polkam 16 was registered by the national Office for Registration of Medical Equipment as the first product of ZdAJ that meets all technical and formal requirements of the safety mark CE. This allows sales of the product on the market of the European Union. The research and development part of designing a therapeutical table for uses in the total body irradiation technique was also concluded in 2005. After the September 11 terrorist attacks on WTC a matter of controlling international borders have become a priority for many countries. In 2005 in ZdAJ IPJ, we conducted many preliminary calculations and experiments analyzing systems of irradiation sources, both photon and neutron as well as systems of detection and designing of signals triggered by controlling objects crossing the border. The results so far have enabled us to formulate a research project which has been positively evaluated by experts and found

  16. Survey and analysis on environmental and electromagnetic effect on instrumentation and control equipment of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, In Koo; Lee, Dong Young; Cha, Kyung Ho

    2001-03-01

    As the instrumentation and control (I and C) equipment suppliers tend to provide digital components rather than conventional analog type components for instrumentation and control systems of nuclear power plants(NPPs), it is unavoidable to adopt digital equipment for safety I and C systems as well as non-safety systems. However, the full introduction of digital equipment for I and C systems of nuclear power plants raises several concerns which have not been considered in conventional analog I and C equipment. The two major examples of the issues of digital systems are environmental/electromagnetic compatibility (EMC) and software reliability. This report presents the survey and research results on environmental and electromagnetic effect on I and C equipment of nuclear power plants to give a guideline for aging management and design process. Electromagnetic site surveys were conducted to be used as a part of technical basis to demonstrate that I and C systems are compatible with the ambient electromagnetic noise in Korean nuclear power plants.

  17. Radiopharmaceutical quality control-Pragmatic approach

    International Nuclear Information System (INIS)

    Barbier, Y.

    1994-01-01

    The quality control must be considered in a practical manner. The radiopharmaceuticals are drugs. They must satisfy the quality assurance control. These products are then conform to Pharmacopeia. But sometimes the user must control some data especially radiochemical purity and pH value. On all the administered solutions four controls are compulsory: radionuclide identity, administered radioactivity, organoleptic character and pH

  18. 7 CFR 981.42 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  19. REDUCTION IN CUTS SPEED AT THE BEGINNING OF A SORTING SIDINGS, EQUIPPED WITH QUASI-CONTINUOUS SPEED CONTROL SYSTEM

    Directory of Open Access Journals (Sweden)

    O. A. Nazarov

    2016-08-01

    Full Text Available Purpose. Clear and uninterrupted operation of humps depends on the quality of technical equipment and control technology of cuts speed. Technology of interval and purposive regulation of cuts speed is used at most humps. The article discusses ways to reduce the cuts rolling speed to a safe level at the beginning of the sorting sidings equipped with quasi-continuous speed control system. Methodology. It proposed three fundamentally different ways to reduce the cuts rolling speed at the beginning of the sorting siding. The analysis of the ways to reduce cuts rolling speed to a safe level at the beginning of the sorting sidings was conducted using simulation the process of cuts rolling from humps equipped with quasi-continuous speed control. Findings. As a result of analysis, the inappropriateness of opposite elevation using on the roll-out part of the hump after the last separation switch point. Spot regulators of cars speed can be used to reduce the cuts rolling speed at the beginning of the sorting siding, but this leads to a division conditions deterioration on the last separating switch points of long cuts with the following after them short cuts. Reducing the cuts rolling speed at the beginning of the sorting siding can be carried out using the beam on a stationary wagon retarders park brake position. Control Algorithm park brake position is quite simple. All produce should be unhooked from it at a safe speed. If the accuracy of the implementation of the set speed output to unhook from the park brake position is low, it is possible to eliminate the error of point regulators cars speed. Originality. The question where to start location point of wagon retarders zone to reduce speed to cut level requires additional research. Reducing rolling cut the speed at the beginning of the sorting sidings can be carried out using the beam on a stationary wagon retarders park brake position. Practical value. Control Algorithm park brake position is quite

  20. Quality control of dosemeters

    International Nuclear Information System (INIS)

    Mendes, L.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are acomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintilation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (Author) [pt

  1. Basic principles of quality assurance to be used in a firm fabricating conventional and nuclear equipments

    International Nuclear Information System (INIS)

    Sauvagnac, B.

    1977-01-01

    The 'Quality Organisation' system to be adopted depends on the equipment sold, the inherent structures of the enterprise and on its importance, of the habits and requirements of the main clients. Iy is stressed however that a certain number of conditions should be required from the start: the determination of the hierarchy and, in particular, that of the General Management, to set up an efficient 'Quality Organisation'; the firm determination to see that decisions are taken by the most competent people in the field concerned and to make them assume official responsibility by signing their work; the development of a system of information and continuous and planned training, whilst remaining very attentive to the risk that a too formal or too dogmatic 'Quality Organisation' might engender [fr

  2. The National System for quality control and the European experience

    International Nuclear Information System (INIS)

    Dimov, A.; Vassileva, J.; Ingilizova, K.; Slavchev, A. and others

    2003-01-01

    Objective: The aim of the work is to present the structure and functions of the National System for quality control (NSQC) in the medical irradiation, created to guarantee the safety and the safe use of the radiological equipment. Material and method: The approaches are studies in the development of the NSQC, applied in Bulgaria and some European Union members - such as Germany and Great Britain - and the specifics of the way in which the Directive for medical irradiation EURATOM 97/43 is implemented in national legislations. Results: The advantages and disadvantages of Bulgarian NSQC are analysed and some ideas for tis improvement are suggested. Conclusions: The developed draft NSQC for medical irradiation is in compliance with the requirement of the European Directive. The real advantages and disadvantages of the NSQC will show after its implementation in the practical radiation protection and control in the country

  3. Toward city-scale water quality control: building a theory for smart stormwater systems

    Science.gov (United States)

    Kerkez, B.; Mullapudi, A. M.; Wong, B. P.

    2016-12-01

    Urban stormwater systems are rarely designed as actual systems. Rather, it is often assumed that individual Best Management Practices (BMPs) will add up to achieve desired watershed outcomes. Given the rise of BMPs and green infrastructure, we ask: does doing "best" at the local scale guarantee the "best" at the global scale? Existing studies suggest that the system-level performance of distributed stormwater practices may actually adversely impact watersheds by increasing downstream erosion and reducing water quality. Optimizing spatial placement may not be sufficient, however, since precipitation variability and other sources of uncertainty can drive the overall system into undesirable states. To that end, it is also important to control the temporal behavior of the system, which can be achieved by equipping stormwater elements (ponds, wetlands, basins, bioswales, etc.) with "smart" sensors and valves. Rather than building new infrastructure, this permits for existing assets to be repurposed and controlled to adapt to individual storm events. While we have learned how to build and deploy the necessary sensing and control technologies, we do not have a framework or theory that combines our knowledge of hydrology, hydraulics, water quality and control. We discuss the development of such a framework and investigate how existing water domain knowledge can be transferred into a system-theoretic context to enable real-time, city-scale stormwater control. We apply this framework to water quality control in an urban watershed in southeast Michigan, which has been heavily instrumented and retrofitted for control over the past year.

  4. Automatic quality control in the production of ceramic substrates by pulsed laser cutting

    DEFF Research Database (Denmark)

    Morace, Renate Erica; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2004-01-01

    This paper deals with the use of optical coordinate measuring machines (CMMs) in the quality control of ceramic substrates produced by a CO2 pulsed laser. A procedure of automatic measurements on a CMM equipped with a CCD camera was developed. In particular, the number and the distribution...... of cavities on the cut face of thin ceramic substrates were investigated and different strategies to assess the depth and the pitch of cavities were compared. Then, the measurement uncertainty for these two critical parameters was evaluated using the method described in ISO/TS 15530-3....

  5. 7 CFR 930.44 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of the...

  6. Auxiliary controllers for data acquisition from scintillation detector electronic equipment

    Energy Technology Data Exchange (ETDEWEB)

    Leonenko, D A; Rybakov, V G; Sen' ko, V A [Gosudarstvennyj Komitet po Ispol' zovaniyu Atomnoj Ehnergii SSSR, Serpukhov. Inst. Fiziki Vysokikh Ehnergij

    1983-01-01

    Structural schemes of auxiliary controllers of three types ensuring compression, filtration and record in buffer storage of data from scintillation detectors electronic equipment are described. The electronics is made according to the CAMAC ideology. The KD-85 controller exercises data readout from analog-to-digital converters (ADC), subtraction of pedestal values, discrimination by the bottom level and record into the buffer storage module. The KD-86 controller summarizes data from all the ADC channels in a crate dicscriminates the summarized data by the upper and bottom levels, and rejects data classified as useless. The KD-90 controller ensures data reading from different modules of the crate according to preset code and records information in the buffer storage module. The considered controllers employ integral microcircuits of the K 155 series. At present the controllers are under experimental operation. Their utilization would permit to adopt new arrangement of data acquisition from experimental facilities in the nearest future and essentially increase the operating efficiency of these facilities.

  7. National phantoms bank for the service of nuclear medicine in Cuba. Utility for the quality control of the instrumentation

    International Nuclear Information System (INIS)

    Varela C, C.; Diaz B, M.; Lopez B, G.M.

    2006-01-01

    Although, most of the applications in Nuclear Medicine have diagnostic ends, its going enlarging considerably the therapeutic applications. So that the diagnostic accuracy or the therapy effectiveness have not been affected, it becomes indispensable the quality control of the instrumentation, independently of its technological complexity and/or its exploitation period. Before the real lack of phantoms in the institutions, it was created a bank that puts to disposition of all the institutions, the existent phantoms in the country, and those that are going acquired, centralized by the State Control of Medical Equipment Center (CCEEM) and with Web access in its place www.eqmed.sld.cu. Having like base the elaboration of the National Protocol for the Quality Control of the Instrumentation in Nuclear Medicine that keeps in mind the international normative and the own existent conditions, were dictated and established two national regulations and its are being carried out the first audits to the instrumentation quality. These have evidenced the partial realization of the established quality controls in the services, the necessity to make aware as for the fulfillment of the criteria and quality concepts for the instrumentation, as well as the necessity to increase the phantoms number to the bank to guarantee the fulfillment of the Quality Control Programs. (Author)

  8. Photovoltaic System Equipped with Digital Command Control and Acquisition

    Directory of Open Access Journals (Sweden)

    Khalil Kassmi

    2013-07-01

    Full Text Available In this paper, we present results concerning the design, the realization and the characterization of a photovoltaic system (PV, equipped with a digital controls: Power Point Tracking (MPPT, charge/discharge lead acid batteries, sun tracker and supervision. These different functions are performed with a microcontroller that has capabilities and functions to the reliability of PV systems (signal generation Pulses Width Modulation (PWM, speed etc.. Concerning the MPPT control operation, we improved the accuracy and reliability of research by improving the search algorithm “Hill Climbing” taking into account the optimal operation of PV panels depending on weather conditions (temperature and light.The experiment of each block shows that the MPPT control converges instantly the operating point of the PV panels around the maximum power point, independently of sudden changes of the illumination or the load. The control blocks charge/discharge battery and sun tracking show good control of charge/discharge lead acid batteries and the need of sun tracker to increase the power supplied by the PV panel. By using the improved MPPT control, loss of power supplied by the PV panels are very low (below 5%.

  9. Quality control analysis at the hospital

    International Nuclear Information System (INIS)

    Kristensen, K.

    1979-01-01

    Quality control analysis is an integral part of quality assurance. In a system as with radiopharmaceuticals where part of the finishing of the product takes place at individual hospitals, the need for quality control analysis at the hospital can be discussed. Data are presented that stresses the importance of quality control by the manufacturer as a basis for limitation of such work at hospitals. A simplified programme is proposed

  10. Design and Development of a Nearable Wireless System to Control Indoor Air Quality and Indoor Lighting Quality

    Directory of Open Access Journals (Sweden)

    Francesco Salamone

    2017-05-01

    Full Text Available The article describes the results of the project “open source smart lamp” aimed at designing and developing a smart object able to manage and control the indoor environmental quality (IEQ of the built environment. A first version of this smart object, built following a do-it-yourself (DIY approach using a microcontroller, an integrated temperature and relative humidity sensor, and techniques of additive manufacturing, allows the adjustment of the indoor thermal comfort quality (ICQ, by interacting directly with the air conditioner. As is well known, the IEQ is a holistic concept including indoor air quality (IAQ, indoor lighting quality (ILQ and acoustic comfort, besides thermal comfort. The upgrade of the smart lamp bridges the gap of the first version of the device providing the possibility of interaction with the air exchange unit and lighting system in order to get an overview of the potential of a nearable device in the management of the IEQ. The upgraded version was tested in a real office equipped with mechanical ventilation and an air conditioning system. This office was occupied by four workers. The experiment is compared with a baseline scenario and the results show how the application of the nearable device effectively optimizes both IAQ and ILQ.

  11. Pediatric interventional radiography equipment: safety considerations

    International Nuclear Information System (INIS)

    Strauss, Keith J.

    2006-01-01

    This paper discusses pediatric image quality and radiation dose considerations in state-of-the-art fluoroscopic imaging equipment. Although most fluoroscopes are capable of automatically providing good image quality on infants, toddlers, and small children, excessive radiation dose levels can result from design deficiencies of the imaging device or inappropriate configuration of the equipment's capabilities when imaging small body parts. Important design features and setup choices at installation and during the clinical use of the imaging device can improve image quality and reduce radiation exposure levels in pediatric patients. Pediatric radiologists and cardiologists, with the help of medical physicists, need to understand the issues involved in creating good image quality at reasonable pediatric patient doses. The control of radiographic technique factors by the generator of the imaging device must provide a large dynamic range of mAs values per exposure pulse during both fluoroscopy and image recording as a function of patient girth, which is the thickness of the patient in the posterior-anterior projection at the umbilicus (less than 10 cm to greater than 30 cm). The range of pulse widths must be limited to less than 10 ms in children to properly freeze patient motion. Variable rate pulsed fluoroscopy can be leveraged to reduce radiation dose to the patient and improve image quality. Three focal spots with nominal sizes of 0.3 mm to 1 mm are necessary on the pediatric unit. A second, lateral imaging plane might be necessary because of the child's limited tolerance of contrast medium. Spectral and spatial beam shaping can improve image quality while reducing the radiation dose. Finally, the level of entrance exposure to the image receptor of the fluoroscope as a function of operator choices, of added filter thickness, of selected pulse rate, of the selected field-of-view and of the patient girth all must be addressed at installation. (orig.)

  12. Interfacing the septa movement (DC motor) equipment to the PS control system and the MIL1553 bus

    CERN Document Server

    Dehavay, Claude

    1993-01-01

    Continuing the rejuvenation of the PS Control system , it is planned to replace the Single Transceiver Hybrid used to interface the Septa Movement Equipment by a G64 system connected to the VME crate via the MIL1553 bus. This note explains the G64 hardware interface and details the standard message as defined in the Control Protocole for Power Converter, RF and Stepping Motor equipment.

  13. Quality control in medical radiology using T.L.D

    International Nuclear Information System (INIS)

    Rolemberg Silva, F.A.; Nascimento Souza, D. do

    2006-01-01

    In this work tests of quality control in beams of X rays have been carried out, at diagnostic level, of two radiological services equipments of Brazilian hospitals (Aracaju, SE). We obtained the air kerma and kerma rate values, the beams efficiency, the coherence between the luminous fields and the referring fields of irradiation and half-value layer to each equipment and set of parameters. The measures of direct form have been obtained using two ionization chambers, one cylindrical and another one with parallel plates. An optional method for accomplishment some of the tests were carried out with CaSO 4 :Dy + Teflon thermoluminescent dosimeters. The values of air kerma were evaluated for three tube voltage, 40, 60 and 81 kV at 1.0 m from the focus of the equipments. For each one of the voltages three distinct current values were chosen besides a fixed value of exposition time. The results showed that the values of air kerma varied between 8.0 μGy and 0.35 μGy. The T.L.D. have revealed useful for the measures if the response to the dose is previously known for each set of beam parameters used for the irradiations. Otherwise, the tests with the dosimeters can serve to evaluate the beams conditions and their reproducibility. The evaluation results of coherence between the luminous fields and the irradiation fields demonstrated that the difference between the radiation and the luminous fields did not exceed 2% of the distance between the focal point and the film. We found satisfactory values for half-value layer. (author)

  14. Establishment of a quality control system of coals; Establecimiento de una Metodologia de Aseguramiento de Calidad en el Analisis de Carbones

    Energy Technology Data Exchange (ETDEWEB)

    1999-09-01

    The pain propose of this project is the establishment of a quality control system in order to assure the feasibility of analytic data used in commercial valorization coals. The programme of quality assurement takes into account the following concepts: - Normalization of analytic methods. - Maintenance and measurements of analysis equipment - Standardization of analysis process. - Quality control inside of laboratory - Standardization of measurement systems between laboratories - External audits of quality process. - Accreditation of alternative systems. - Personnel education necessities. In order to be an useful tool, the programme has been consider under this three aspects: reliableness, rapidness, and simpleness. The process is based in: validation of method, validation of origin, and validation by coherence. All that is integrated in an informatic system. (Author)

  15. Experience of Implementing a Distributed Control System for Thermal and Mechanical and Electrical Equipment at the South-West CHP

    Energy Technology Data Exchange (ETDEWEB)

    Babkin, K. V., E-mail: babkin@uztec.ru; Tsvetkov, M. S.; Kostyuk, R. I.; Chugin, A. V. [SC “South-West CHP” (Russian Federation); Bilenko, V. A.; Molchanov, K. A.; Fedunov, V. V. [JSC “Interautomatika” (Russian Federation)

    2015-01-15

    Results of implementing an SPPA-T3000-based unified distributed control system for thermal and mechanical and electrical equipment at the South-West CHP are discussed. Hardware solutions for integration with local control systems, control of electrical equipment in compliance with the standards IEC 61850, Modbus RTU, and communication between the plant control system and the System Operator of the Unified Power System are described.

  16. Experience of Implementing a Distributed Control System for Thermal and Mechanical and Electrical Equipment at the South-West CHP

    International Nuclear Information System (INIS)

    Babkin, K. V.; Tsvetkov, M. S.; Kostyuk, R. I.; Chugin, A. V.; Bilenko, V. A.; Molchanov, K. A.; Fedunov, V. V.

    2015-01-01

    Results of implementing an SPPA-T3000-based unified distributed control system for thermal and mechanical and electrical equipment at the South-West CHP are discussed. Hardware solutions for integration with local control systems, control of electrical equipment in compliance with the standards IEC 61850, Modbus RTU, and communication between the plant control system and the System Operator of the Unified Power System are described

  17. Current aspects in the development of the quality control in the conventional X-ray diagnostic radiology

    International Nuclear Information System (INIS)

    Stoeva, M.; Velkova, K.

    2004-01-01

    The role of the X-ray diagnostic radiology as one of the main factors forming the general public dose is indisputable. Following the requirement for justification of the application of X-rays for medical purposes, certain criteria for assessment of the parameters of the X-ray diagnostic equipment are formed and maximum permissible values defined. The latter are developed by the international and national radiation protection organizations and introduced both in the international and national legislation. The importance of the quality assurance concept for the radiation protection of the patient and staff in diagnostic radiology turned the quality control into main toll for obtaining high quality images with minimum dose to the patient and staff. X-ray diagnostics is one of the most common methods used in the medical practice. This is the main reason for the increase of the quality control protocols, winch makes their handling difficult. The latest developments in this area bring forward the idea for the development of specialized quality control software, which is capable of: 1) full or semi-automated calculation and assessment of the parameters of the X-ray diagnostic units; 2) tools for data handling and access; 3) tools for data analysis based on predefined procedures

  18. 14 CFR 21.139 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which he...

  19. 33 CFR 385.21 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product that...

  20. CONTROL DE MALEZA EN DISTRITOS DE RIEGO CON EQUIPOS LIGEROS WEED CONTROL IN IRRIGATION DISTRICTS WITH LIGHT WEIGHT EQUIPMENT

    Directory of Open Access Journals (Sweden)

    José Ramón Lomelí Villanueva

    2010-12-01

    Full Text Available En México el control mecánico de maleza, tradicionalmente se realizaba con maquinaria inadecuada lo cual provocaba daños en los taludes y modificaciones de la sección hidráulica. Para resolver este problema, actualmente se utilizan los equipos ligeros que permiten el desarrollo de una cubierta vegetal, que no interfiere con el flujo del agua y su sistema radical retiene el suelo, lo cual reduce la erosión y mantiene en condiciones estables los taludes. El presente trabajo aborda los aspectos relativos a características y criterios para la selección de los implementos y la secuencia para su utilización. El costo de las operaciones para el control de maleza en canales, drenes y caminos se ha reducido un 39,21% con respecto a utilizar maquinaria inadecuada. La versatilidad de los equipos ligeros permite emplear el implemento más adecuado para cada tipo de maleza. En México, el inventario actual es de 263 equipos ligeros que tienen un potencial de aplicación para el control de la maleza, en la totalidad de los caminos, el 90% de canales y el 70% de drenes de los Distritos de Riego.In Mexico, the mechanical weed control was traditionally carried out with inadequate equipment which caused damage to the slopes and changes in the hydraulic section. In order to solve this problem, light weight equipment is currently being used to allow the development of a vegetation cover to retain soil with no interference with water flow, reducing erosion and maintaining stable conditions in the slopes. This paper addresses aspects related to characteristics and criteria for selecting and sequencing tools for use. The costs of weed control in irrigation channels, drains and roads have been reduced 39.21% compared to using inadequate equipment. The versatility of light weight equipment allows the use of the most appropriate implement for each weed. In Mexico, the current inventory includes 263 light weight devices with which a potential weed control of 90

  1. Data acquisition, remote control and equipment monitoring for ISOLDE RILIS

    Energy Technology Data Exchange (ETDEWEB)

    Rossel, R.E., E-mail: ralf.erik.rossel@cern.ch [CERN, Geneva (Switzerland); Institut für Physik, Johannes Gutenberg-Universität, Mainz (Germany); Hochschule RheinMain, Fachbereich Design Informatik Medien, Wiesbaden (Germany); Fedosseev, V.N.; Marsh, B.A. [CERN, Geneva (Switzerland); Richter, D. [Hochschule RheinMain, Fachbereich Design Informatik Medien, Wiesbaden (Germany); Rothe, S. [CERN, Geneva (Switzerland); Institut für Physik, Johannes Gutenberg-Universität, Mainz (Germany); Wendt, K.D.A. [Institut für Physik, Johannes Gutenberg-Universität, Mainz (Germany)

    2013-12-15

    Highlights: • The requirements for continuous and automated RILIS operation are outlined. • Laser wavelength, power, beam position and pulse timing are continuously monitored. • A network-extended LabVIEW-based equipment operation framework was developed. • The system serves as a foundation for collaborative laser spectroscopy data acquisition. • Example applications have been successfully tested with ISOLDE experiment setups. -- Abstract: With a steadily increasing on-line operation time up to a record 3000 h in the year 2012, the Resonance Ionization Laser Ion Source (RILIS) is one of the key components of the ISOLDE on-line isotope user facility at CERN. Ion beam production using the RILIS is essential for many experiments due to the unmatched combination of ionization efficiency and selectivity. To meet the reliability requirements the RILIS is currently operated in shift duty for continuous maintenance of crucial laser parameters such as wavelength, power, beam position and timing, as well as ensuring swift intervention in case of an equipment malfunction. A recent overhaul of the RILIS included the installation of new pump lasers, commercial dye lasers and a complementary, fully solid-state titanium:sapphire laser system. The framework of the upgrade also required the setup of a network-extended, LabVIEW-based system for data acquisition, remote control and equipment monitoring, to support RILIS operators as well as ISOLDE users. The system contributes to four key aspects of RILIS operation: equipment monitoring, machine protection, automated self-reliance, and collaborative data acquisition. The overall concept, technologies used, implementation status and recent applications during the 2012 on-line operation period will be presented along with a summary of future developments.

  2. Chapter 8: Quality assurance

    International Nuclear Information System (INIS)

    2001-01-01

    The main efforts of Nuclear Regulatory Authority of the Slovak Republic (UJD) have been focused on inspection of quality assurance programmes of Slovak Power Stations, plc. and its daughter companies at Bohunice and Mochovce. Two quality assurance inspections in the area of periodical in service inspections (V-2 units) and tests of selected equipment (NPP V-2 units) and operation control (V-1 units) has been performed at NPPs Bohunice. One violation of decree on quality assurance of selected equipment has been found in the area of documentation archiving. The inspection concerning the implementation of quality assurance programme for operation of NPP Mochovce in the area of operation control has been performed focused on safety aspects of operation, operational procedures, control of operational events and feedback from operational experience. The results of this inspection were positive. Inspection of implementation of quality assurance programme for operation of radioactive waste repository (RU RAW) at the Mochovce location has been performed focused on receiving of containers, with radioactive wastes, containers handling, radiation monitoring, activities of documentation control and radiation protection at the repository site. No serious deficiencies have been found out. Also one inspection of experimental nuclear installations of VUJE Trnava at Jaslovske Bohunice site has been performed focused on procurement control, quality audits, documentation and quality records control when performing activities at experimental nuclear installations. The activity on development of internal quality assurance system continued. The implementation of this system will assure quality and effective fulfilment enlarged tasks of UJD with limited resources for its activity. The analyses of possible use of existing internal administrative control documentation as a basis for future quality system procedures was performed in co-operation with an external specialised organisation. The

  3. [Equipping the bacteriological laboratories of a tuberculosis service as the most important element of assurance of the quality and safety of their work].

    Science.gov (United States)

    Sevast'ianova, E V; Martynova, L P; Barilo, V N; Golyshevskaia, V I; Shul'gina, M V

    2009-01-01

    By taking into account the present requirements for the equipping of the laboratories, the authors have drawn up the minimum standard list of equipment, as well as a list of additional equipment for the specialized bacteriological laboratory of a tuberculosis-controlling institution, which performs microbiological studies for the diagnosis and control of chemotherapy for tuberculosis. The specifications and characteristics of the baric types of equipment used to fit out the laboratories under the present conditions are described. Equipping the laboratories in accordance with the draw-up lists is shown to ensure a qualitative, effective, and safe work. Recommendations on how to supply the laboratories with equipment, to make the optimal choice, and to use consumables for tests are given.

  4. Improvement of remote control system of automatic ultrasonic equipment for inspection of reactor pressure vessel

    International Nuclear Information System (INIS)

    Cheong, Yong Moo; Jung, H. K.; Joo, Y. S.; Koo, K. M.; Hyung, H.; Sim, C. M.; Gong, U. S.; Kim, S. H.; Lee, J. P.; Rhoo, H. C.; Kim, M. S.; Ryoo, S. K.; Choi, C. H.; Oh, K. I.

    1999-12-01

    One of the important issues related to the nuclear safety is in-service inspection of reactor pressure vessel (RPV). A remote controlled automatic ultrasonic method is applied to the inspection. At present the automatic ultrasonic inspection system owned by KAERI is interrupted due to degradation of parts. In order to resume field inspection new remote control system for the equipment was designed and installed to the existing equipment. New ultrasonic sensors and their modules for RPV inspection were designed and fabricated in accordance with the new requirements of the inspection codes. Ultrasonic sensors were verified for the use in the RPV inspection. (author)

  5. Related regulation of quality control of industrial products

    International Nuclear Information System (INIS)

    1983-04-01

    This book introduce related regulation of quality control of industrial products, which includes regulations of industrial products quality control, enforcement ordinance of industrial products quality control, enforcement regulation of quality control of industrial products, designated items with industrial production quality indication, industrial production quality test, and industrial production quality test organization and management tips of factory quality by grade.

  6. Lighting Control System for Premises with Display Screen Equipment

    Science.gov (United States)

    Kudryashov, A. V.

    2017-11-01

    The use of Display Screen Equipment (DSE) at enterprises allows one to increase the productivity and safety of production, minimize the number of personnel and leads to the simplification of the work of specialists, but on the other side, changes usual working conditions. If the personnel works with displays, visual fatigue develops more quickly which contributes to the emergence of nervous tension, stress and possible erroneous actions. Low interest of the lighting control system developers towards the rooms with displays is dictated by special requirements for coverage by sanitary and hygienic standards (limiting excess workplace illumination). We decided to create a combined lighting system which works considering daylight illumination and artificial light sources. The brightness adjustment of the LED lamps is carried out according to the DALI protocol, adjustment of the natural illumination by means of smart glasses. The technical requirements for a lighting control system, the structural-functional scheme and the algorithm for controlling the operation of the system have been developed. The elements of control units, sensors and actuators have been selected.

  7. 78 FR 31459 - Approval and Promulgation of Air Quality Implementation Plans; Connecticut; Reasonably Available...

    Science.gov (United States)

    2013-05-24

    ... equipment is required to control VOC emissions by one of the following methods: Use of an enclosed gun... keeping; air pollution control equipment requirements; surface preparation requirements; and spray gun... and Promulgation of Air Quality Implementation Plans; Connecticut; Reasonably Available Control...

  8. Estimation of the dose to patients in conventional radiology to starting from the data obtained in the quality controls

    International Nuclear Information System (INIS)

    Parra Osorio, V.; Casado Villalon, F. J.; Ortega Cantos, E.; Navarro Guirado, F.; Moreno Saiz, C.; Martin-Viera Cueto, J. A.

    2013-01-01

    The objective of this study is to estimate the dose on the surface of the entry of the patient on simple scans with x-rays from the information collected by the unit of Radiophysics in quality controls of equipment.To this end, we have selected three scans collected in this legislation: PA chest and Abdomen AP skull AP. (Author)

  9. CONTROL SYSTEM FOR UNMANNED AIRCRAFT EQUIPPED WITH ROBOTICS ARM

    Directory of Open Access Journals (Sweden)

    Alexei A. Margun

    2014-11-01

    Full Text Available The paper deals with the problem of control system synthesis for multi rotational UAV equipped with robotics arm. Control algorithm is proposed based on the method of feedback linearization and synthesis of proportional-differential controller with the real time computation of the inertia tensor and center of mass changes and compensation of the reactive torque generated by the dynamics of the manipulator. Quadrocopter with attached articulated manipulator is selected as a model of the control object. Systems of equations describing the behavior of considered dynamical system are obtained according to the Newton and Euler-Lagrange laws. Expressions are offered, defining the inertia tensor and the position of the system center of mass depending on the current position of the manipulator, and the torque acting on the quadrocopter from the manipulator. Feedback linearization with arm influence compensation on quadrocopter is applied for the resulting nonlinear coupled system. As a result, robot dynamics equations have been converted to a linear stationary system. Converted system control is achieved by a proportional-differential controller. Examined system simulation is done with control method described in the paper and the classical method based on a proportional-differential controller. Simulation results confirm the effectiveness of the proposed approach and demonstrate that the proposed approach provides higher accuracy of the tracking error, than control method by means of proportional-differential regulator.

  10. Data acquisition, remote control and equipment monitoring for ISOLDE RILIS

    CERN Document Server

    Rossel, R E; Richter, D; Wendt, K D A; Rothe, S; Marsh, B A

    2013-01-01

    With a steadily increasing on-line operation time up to a record 3000 h in the year 2012, the Resonance Ionization Laser Ion Source (RILIS) is one of the key components of the ISOLDE on-line isotope user facility at CERN. Ion beam production using the RILIS is essential for many experiments due to the unmatched combination of ionization efficiency and selectivity. To meet the reliability requirements the RILIS is currently operated in shift duty for continuous maintenance of crucial laser parameters such as wavelength, power, beam position and timing, as well as ensuring swift intervention in case of an equipment malfunction. A recent overhaul of the RILIS included the installation of new pump lasers, commercial dye lasers and a complementary, fully solid-state titanium:sapphire laser system. The framework of the upgrade also required the setup of a network-extended, LabVIEW-based system for data acquisition, remote control and equipment monitoring, to support RILIS operators as well as ISOLDE users. The syst...

  11. Process equipment data organisation in CERN PS controls

    International Nuclear Information System (INIS)

    Casalegno, L.; Cuperus, J.; Sicard, C.H.

    1990-01-01

    The CERN PS control system has a widely distributed architecture, mainly for fast response in a real-time environment. The organisation of the data for equipment access must be compatible with this architecture and give efficient program access to the data. Moreover, it must also offer managerial features such as data integrity, easy backup and restoration, adaptibility to changes in data structure, initialisation, data-entry facilities and automatic documentation. This paper shows how one can take advantage of a commercial data-base management system with its associated tools, adding to it some object-oriented programming concepts to meet the objectives of a manageable distributed data organisation having good run-time performance features and using a reasonable manpower investment. (orig.)

  12. 46 CFR 28.130 - Survival craft equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Survival craft equipment. 28.130 Section 28.130 Shipping... INDUSTRY VESSELS Requirements for All Vessels § 28.130 Survival craft equipment. (a) General. Each item of survival craft equipment must be of good quality, effective for the purpose it is intended to serve, and...

  13. A status report on dual energy x-ray absorptiometry quality control in Korea

    International Nuclear Information System (INIS)

    Kim, Jung Su; Ro, Young Hoon; Lee, In Ju; Kim, Jung Min; Kim, Sung Su; Kim, Kyoung Ah

    2016-01-01

    Dual-energy X-ray absorptiometry (DEXA) is the most widely used technical instrument for evaluating bone mineral content (BMC) and density (BMD) in patients of all ages. In 2016, DEXA devices operating is 5617 in Korea. In this study we investigated the quality of management practices survey for DEXA equipment and we analyzed it. We got a survey response rate of 12.6%. Accurate bone densitometry test is used data for estimation a patient's risk of fracture. However, improper bone densitometry will increase the possibility of causing a false positive. Therefore. it is essential to use the proper aids accurate bone densitomenty to be performed, and the quality control of the device to reduce the error factor of the tester through the training to reduce error for the device and the attitude

  14. A status report on dual energy x-ray absorptiometry quality control in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su [Dept. of Radiogic Technology, Chungbuk Health and Science University, Cheongju (Korea, Republic of); Ro, Young Hoon; Lee, In Ju; Kim, Jung Min [Dept. of Bio-convergence Engineering, Korea University Graduate School, Seoul (Korea, Republic of); Kim, Sung Su [Dept. of Healthcare Management, Cheongju University, Cheongju (Korea, Republic of); Kim, Kyoung Ah [Dept. of Diagnostic Radiology, CHA Bundang Medical Center, CHA University, Sungnam (Korea, Republic of)

    2016-12-15

    Dual-energy X-ray absorptiometry (DEXA) is the most widely used technical instrument for evaluating bone mineral content (BMC) and density (BMD) in patients of all ages. In 2016, DEXA devices operating is 5617 in Korea. In this study we investigated the quality of management practices survey for DEXA equipment and we analyzed it. We got a survey response rate of 12.6%. Accurate bone densitometry test is used data for estimation a patient's risk of fracture. However, improper bone densitometry will increase the possibility of causing a false positive. Therefore. it is essential to use the proper aids accurate bone densitomenty to be performed, and the quality control of the device to reduce the error factor of the tester through the training to reduce error for the device and the attitude.

  15. Plant equipment integrity monitoring and diagnosing method and device therefor, plant equipment maintenance and inspection time determining method and device therefor, as well as nuclear power plant

    International Nuclear Information System (INIS)

    Kato, Takahiko; Ando, Masashi; Osumi, Katsumi; Horiuchi, Tetsuo; Asakura, Yamato; Akamine, Kazuhiko.

    1995-01-01

    The present invention can accurately forecast a time for occurrence of troubles of plant equipments in contact with recycling water, to conduct its maintenance and inspection before occurrence of the troubles. Namely, change of water quality in plant equipments caused by corrosion of recycling water occurred in constitutional parts of the plant equipments is measured. The time upon occurrence of the troubles of the plant equipments to corrosion of the recycling water is forecast based on the measured value. A time till the occurrence of the change of water quality after starting the use of the plant equipments is calculated based on the measured value. The calculated time is compared with a correlation between the time of occurrence of the troubles after starting the use of the plant equipments and the time of occurrence of change of the water quality, to forecast the time of occurrence of the troubles. Preferably, electroconductivity and pH of recycling water in the inside or at the exit of the plant equipments are measured as an object for the measurement of change of water quality. (I.S.)

  16. Quality and reliability control on assemblies

    International Nuclear Information System (INIS)

    Mueller, H.

    1976-01-01

    Taking as an example electronic assemblies in printed circuit board engineering, quality control during manufacture is dealt with. After giving a survey of four phases of quality and reliability control, some specific methods of quality control are dealt with by means of a flowchart, and by some examples the necessity and the success of these measures are shown. (RW) [de

  17. Quality Control in Mammography: Image Quality and Patient Doses

    International Nuclear Information System (INIS)

    Ciraj Bjelac, O.; Arandjic, D.; Boris Loncar, B.; Kosutic, D.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. The purpose of this paper is preliminary evaluation the mammography practice in Serbia, in terms of both quality control indicators, i.e. image quality and patient doses. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Correlation between image contrast and mean glandular doses was demonstrated. Systematic implementation of quality control protocol should provide satisfactory performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practicable. (author)

  18. Equipment design guidance document for flammable gas waste storage tank new equipment

    International Nuclear Information System (INIS)

    Smet, D.B.

    1996-01-01

    This document is intended to be used as guidance for design engineers who are involved in design of new equipment slated for use in Flammable Gas Waste Storage Tanks. The purpose of this document is to provide design guidance for all new equipment intended for application into those Hanford storage tanks in which flammable gas controls are required to be addressed as part of the equipment design. These design criteria are to be used as guidance. The design of each specific piece of new equipment shall be required, as a minimum to be reviewed by qualified Unreviewed Safety Question evaluators as an integral part of the final design approval. Further Safety Assessment may be also needed. This guidance is intended to be used in conjunction with the Operating Specifications Documents (OSDs) established for defining work controls in the waste storage tanks. The criteria set forth should be reviewed for applicability if the equipment will be required to operate in locations containing unacceptable concentrations of flammable gas

  19. Methods of equipment choice in shotcreting

    Science.gov (United States)

    Sharapov, R. R.; Yadykina, V. V.; Stepanov, M. A.; Kitukov, B. A.

    2018-03-01

    Shotcrete is widely used in architecture, hydraulic engineering structures, finishing works in tunnels, arc covers and ceilings. The problem of the equipment choice in shotcreting is very important. The main issues influencing the equipment choice are quality improvement and intensification of shotcreting. Main parameters and rational limits of technological characteristic of machines used in solving different problems in shotcreting are described. It is suggested to take into account peculiarities of shotcrete mixing processes and peculiarities of applying these mixtures with compressed air kinetic energy. The described method suggests choosing a mixer with the account of energy capacity, Reynolds number and rotational frequency of the mixing drum. The suggested choice procedure of the equipment nomenclature allows decreasing exploitation costs, increasing the quality of shotcrete and shotcreting in general.

  20. VGI QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    C. C. Fonte

    2015-08-01

    Full Text Available This paper presents a framework for considering quality control of volunteered geographic information (VGI. Different issues need to be considered during the conception, acquisition and post-acquisition phases of VGI creation. This includes items such as collecting metadata on the volunteer, providing suitable training, giving corrective feedback during the mapping process and use of control data, among others. Two examples of VGI data collection are then considered with respect to this quality control framework, i.e. VGI data collection by National Mapping Agencies and by the most recent Geo-Wiki tool, a game called Cropland Capture. Although good practices are beginning to emerge, there is still the need for the development and sharing of best practice, especially if VGI is to be integrated with authoritative map products or used for calibration and/or validation of land cover in the future.

  1. Hot roller embossing system equipped with a temperature margin-based controller

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seyoung, E-mail: seyoungkim@kimm.re.kr; Son, Youngsu; Lee, Sunghee; Ham, Sangyong; Kim, Byungin [Department of Robotics and Mechatronics, Korea Institute of Machinery and Materials (KIMM), Daejeon (Korea, Republic of)

    2014-08-15

    A temperature control system was proposed for hot roller embossing. The roll surface was heated using induction coils and cooled with a circulating chilled water system. The temperature of the roll surface was precisely controlled by a temperature margin-based control algorithm that we developed. Implementation of the control system reduced deviations in the roll surface temperature to less than ±2 °C. The tight temperature control and the ability to rapidly increase and decrease the roll temperature will allow optimum operating parameters to be developed quickly. The temperature margin-based controller could also be used to optimize the time course of electrical power and shorten the cooling time by choosing an appropriate temperature margin, possibly for limited power consumption. The chiller-equipped heating roll with the proposed control algorithm is expected to decrease the time needed to determine the optimal embossing process.

  2. Hot roller embossing system equipped with a temperature margin-based controller

    International Nuclear Information System (INIS)

    Kim, Seyoung; Son, Youngsu; Lee, Sunghee; Ham, Sangyong; Kim, Byungin

    2014-01-01

    A temperature control system was proposed for hot roller embossing. The roll surface was heated using induction coils and cooled with a circulating chilled water system. The temperature of the roll surface was precisely controlled by a temperature margin-based control algorithm that we developed. Implementation of the control system reduced deviations in the roll surface temperature to less than ±2 °C. The tight temperature control and the ability to rapidly increase and decrease the roll temperature will allow optimum operating parameters to be developed quickly. The temperature margin-based controller could also be used to optimize the time course of electrical power and shorten the cooling time by choosing an appropriate temperature margin, possibly for limited power consumption. The chiller-equipped heating roll with the proposed control algorithm is expected to decrease the time needed to determine the optimal embossing process

  3. 7 CFR 58.928 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be...

  4. Expert database system for quality control

    Science.gov (United States)

    Wang, Anne J.; Li, Zhi-Cheng

    1993-09-01

    There are more competitors today. Markets are not homogeneous they are fragmented into increasingly focused niches requiring greater flexibility in the product mix shorter manufacturing production runs and above allhigher quality. In this paper the author identified a real-time expert system as a way to improve plantwide quality management. The quality control expert database system (QCEDS) by integrating knowledge of experts in operations quality management and computer systems use all information relevant to quality managementfacts as well as rulesto determine if a product meets quality standards. Keywords: expert system quality control data base

  5. About water chemistry influence on equipment reliability of NPP with RBMK-1000

    International Nuclear Information System (INIS)

    Berezina, I.G.; Styazhkin, P.S.; Kritskij, V.G.

    2001-01-01

    In the paper the experience of a quantitative valuation of coolant quality influence on a reliability of some equipment elements of NPP with RBMK-1000 is offered. The choice is made of coolant quality integral parameter. The connection between indices values of coolant quality and reliability of major elements of circulation circuit equipment (including fuel claddings) is established. The reliability improvement of equipment elements operation is supported by high water chemistry quality. (orig.)

  6. 7 CFR 58.335 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow...

  7. The performance of a prototype device designed to evaluate general quality parameters of X-ray equipment

    Science.gov (United States)

    Murata, C. H.; Fernandes, D. C.; Lavínia, N. C.; Caldas, L. V. E.; Pires, S. R.; Medeiros, R. B.

    2014-02-01

    The performance of radiological equipment can be assessed using non-invasive methods and portable instruments that can analyze an X-ray beam with just one exposure. These instruments use either an ionization chamber or a state solid detector (SSD) to evaluate X-ray beam parameters. In Brazil, no such instruments are currently being manufactured; consequently, these instruments come at a higher cost to users due to importation taxes. Additionally, quality control tests are time consuming and impose a high workload on the X-ray tubes when evaluating their performance parameters. The assessment of some parameters, such as the half-value layer (HVL), requires several exposures; however, this can be reduced by using a SSD that requires only a single exposure. One such SSD uses photodiodes designed for high X-ray sensitivity without the use of scintillation crystals. This sensitivity allows one electron-hole pair to be created per 3.63 eV of incident energy, resulting in extremely high and stable quantum efficiencies. These silicon photodiodes operate by absorbing photons and generating a flow of current that is proportional to the incident power. The aim of this study was to show the response of the solid sensor PIN RD100A detector in a multifunctional X-ray analysis system that is designed to evaluate the average peak voltage (kVp), exposure time, and HVL of radiological equipment. For this purpose, a prototype board that uses four SSDs was developed to measure kVp, exposure time, and HVL using a single exposure. The reproducibility and accuracy of the results were compared to that of different X-ray beam analysis instruments. The kVp reproducibility and accuracy results were 2% and 3%, respectively; the exposure time reproducibility and accuracy results were 2% and 1%, respectively; and the HVL accuracy was ±2%. The prototype's methodology was able to calculate these parameters with appropriate reproducibility and accuracy. Therefore, the prototype can be considered

  8. Development and assembly of equipment for non destructive assay system control using nuclear radiation

    International Nuclear Information System (INIS)

    Melo, Jose Altino Tupinamba

    2006-01-01

    Nondestructive Assay (NDA) is applied to machines and components quality tests. These elements would not have a good performance if they were conceived without concern about the mechanical project quality, used materials, manufacture processes and inspection and maintenance methodology. There are constant developments in high level of technology with the objective of guaranteeing the components quality and the good functioning of these machines, in the mechanics, naval, aeronautical, petrochemical and steel industry, energy and nuclear generation as well. The globalization in the industry lines is a fact, leading to an increase in the multinational projects and products. The following questions arise: how to assure the high quality of components and processes? How to optimize the test methods to assure that the materials do not have defects affecting the performance of the components? The answers to the questions above are found in the application of NDA. The complex materials analysis (inhomogeneous) using NDA requires a detailed study of the sensors response signal. In this work, a measure and control system of non destructive processes was developed, using a radioactive source with a defined energy in function of the material to be analyzed. This system involves: (a) Interface of input/output (I/O) (the Hardware) and (b) graphical Interface (Software). In the non destructive analysis, it is made the comparison of the signal proceeding from the sensor with a signal preset (Set Point) or analogical signal of reference (Base Line), which is adjusted in the I/O Interface. Analyzed the signal, the system will make the decision: (a) to reject or (b) to accept the analyzed material. The I/O Interface is implemented by electronic equipment with a MCS51. The purpose of this interface is to supply conditions to exchange information, using serial RS232, between the sensor and the microcomputer. The graphical Interface (software) is written in visual C++ language (author)

  9. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Verdera, E.S.

    1994-01-01

    The quality control of radiopharmaceuticals is based in physics, physics-chemical and biological controls. Between the different controls can be enumerated the following: visual aspect,side, number of particle beams,activity,purity,ph,isotonicity,sterility,radioinmunoessay,toxicity,stability and clinical essay

  10. Radiological equipment analyzed by specific developed phantoms and software

    International Nuclear Information System (INIS)

    Soto, M.; Campayo, J. M.; Mayo, P.; Verdu, G.; Rodenas, F.

    2010-10-01

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be computerized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In case of film-screen equipment s this analysis could be applied digitalising the image in a professional scanner. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment s. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment s and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques... etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (m As). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (Author)

  11. Radiological equipment analyzed by specific developed phantoms and software

    Energy Technology Data Exchange (ETDEWEB)

    Soto, M.; Campayo, J. M. [Logistica y Acondicionamientos Industriales SAU, Sorolla Center, Local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Mayo, P. [TITANIA Servicios Tecnologicos SL, Sorolla Center, Local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Verdu, G.; Rodenas, F., E-mail: m.soto@lainsa.co [ISIRYIM Universidad Politecnica de Valencia, Camino de Vera s/n, Valencia (Spain)

    2010-10-15

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be computerized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In case of film-screen equipment s this analysis could be applied digitalising the image in a professional scanner. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment s. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment s and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques... etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (m As). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (Author)

  12. 7 CFR 58.642 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.642 Section 58.642... Procedures § 58.642 Quality control tests. All mix ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow line samples as...

  13. Quality in the fabrication process

    International Nuclear Information System (INIS)

    Romano, A.; Aguirre, F.

    2010-01-01

    Enusa commitment to quality in the manufacture process materializes in the application of the most advanced product quality control technologies such as not-destructive inspection techniques, like artificial vision, X-ray or UT inspection, or process parameter statistical control systems. Quality inspectors are trained and certified by the main National Quality Organizations and receive periodic training under a formal company training program that constantly updates their qualification. Fabrication quality control reliability is based on a strategy that prioritizes redundancy of critical inspection equipment's and inspection personnel knowledge polyvalence. Furthermore, improvement in fabrication quality is obtained by a systematic application of the six sigma methodology where added value is created in projects integrating crosscutting company knowledge, reinforcing the global company vision that the fuel business is based on quality. (Author)

  14. Quality control of nuclear medicine instrumentation

    International Nuclear Information System (INIS)

    Mould, R.F.

    1983-09-01

    The proceedings of a conference held by the Hospital Physicists' Association in London 1983 on the quality control of nuclear medicine instrumentation are presented. Section I deals with the performance of the Anger gamma camera including assessment during manufacture, acceptance testing, routine testing and long-term assessment of results. Section II covers interfaces, computers, the quality control problems of emission tomography and the quality of software. Section III deals with radionuclide measurement and impurity assessment and Section IV the presentation of images and the control of image quality. (U.K.)

  15. A new hyperspectral imaging based device for quality control in plastic recycling

    Science.gov (United States)

    Bonifazi, G.; D'Agostini, M.; Dall'Ava, A.; Serranti, S.; Turioni, F.

    2013-05-01

    The quality control of contamination level in the recycled plastics stream has been identified as an important key factor for increasing the value of the recycled material by both plastic recycling and compounder industries. Existing quality control methods for the detection of both plastics and non-plastics contaminants in the plastic waste streams at different stages of the industrial process (e.g. feed, intermediate and final products) are currently based on the manual collection from the stream of a sample and on the subsequent off-line laboratory analyses. The results of such analyses are usually available after some hours, or sometimes even some days, after the material has been processed. The laboratory analyses are time-consuming and expensive (both in terms of equipment cost and their maintenance and of labour cost).Therefore, a fast on-line assessment to monitor the plastic waste feed streams and to characterize the composition of the different plastic products, is fundamental to increase the value of secondary plastics. The paper is finalized to describe and evaluate the development of an HSI-based device and of the related software architectures and processing algorithms for quality assessment of plastics in recycling plants, with particular reference to polyolefins (PO). NIR-HSI sensing devices coupled with multivariate data analysis methods was demonstrated as an objective, rapid and non-destructive technique that can be used for on-line quality and process control in the recycling process of POs. In particular, the adoption of the previous mentioned HD&SW integrated architectures can provide a solution to one of the major problems of the recycling industry, which is the lack of an accurate quality certification of materials obtained by recycling processes. These results could therefore assist in developing strategies to certify the composition of recycled PO products.

  16. Charging equipment. Ladegeraet

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, E

    1981-09-17

    The invention refers to a charging equipment, particularly on board charging equipment for charging traction batteries of an electric vehicle from the AC mains supply, consisting of a DC converter, which contains a controlled power transistor, a switching off unloading circuit and a power transmitter, where the secondary winding is connected in series with a rectifier diode, and a smoothing capacitor is connected in parallel with this series circuit. A converter module is provided, which consists of two DC voltage converters, whose power transistors are controlled by a control circuit in opposition with a phase displacement of 180/sup 0/.

  17. [Hospital clinical engineer orientation and function in the maintenance system of hospital medical equipment].

    Science.gov (United States)

    Li, Bin; Zheng, Yunxin; He, Dehua; Jiang, Ruiyao; Chen, Ying; Jing, Wei

    2012-03-01

    The quantity of medical equipment in hospital rise quickly recent year. It provides the comprehensive support to the clinical service. The maintenance of medical equipment becomes more important than before. It is necessary to study on the orientation and function of clinical engineer in medical equipment maintenance system. Refer to three grade health care system, the community doctors which is called General practitioner, play an important role as the gatekeeper of health care system to triage and cost control. The paper suggests that hospital clinical engineer should play similar role as the gatekeeper of medical equipment maintenance system which composed by hospital clinical engineer, manufacture engineer and third party engineer. The hospital clinical engineer should be responsible of guard a pass of medical equipment maintenance quality and cost control. As the gatekeeper, hospital clinical engineer should take the responsibility of "General engineer" and pay more attention to safety and health of medical equipment. The responsibility description and future transition? development of clinical engineer as "General Engineer" is discussed. More attention should be recommended to the team building of hospital clinical engineer as "General Engineer".

  18. Improvement of remote control system of automatic ultrasonic equipment for inspection of reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, Yong Moo; Jung, H. K.; Joo, Y. S.; Koo, K. M.; Hyung, H.; Sim, C. M.; Gong, U. S.; Kim, S. H.; Lee, J. P.; Rhoo, H. C.; Kim, M. S.; Ryoo, S. K.; Choi, C. H.; Oh, K. I

    1999-12-01

    One of the important issues related to the nuclear safety is in-service inspection of reactor pressure vessel (RPV). A remote controlled automatic ultrasonic method is applied to the inspection. At present the automatic ultrasonic inspection system owned by KAERI is interrupted due to degradation of parts. In order to resume field inspection new remote control system for the equipment was designed and installed to the existing equipment. New ultrasonic sensors and their modules for RPV inspection were designed and fabricated in accordance with the new requirements of the inspection codes. Ultrasonic sensors were verified for the use in the RPV inspection. (autho0008.

  19. Hall-effect based semi-fast AC on-board charging equipment for electric vehicles.

    Science.gov (United States)

    Milanés-Montero, María Isabel; Gallardo-Lozano, Javier; Romero-Cadaval, Enrique; González-Romera, Eva

    2011-01-01

    The expected increase in the penetration of electric vehicles (EV) and plug-in hybrid electric vehicles (PHEV) will produce unbalanced conditions, reactive power consumption and current harmonics drawn by the battery charging equipment, causing a great impact on the power quality of the future smart grid. A single-phase semi-fast electric vehicle battery charger is proposed in this paper. This ac on-board charging equipment can operate in grid-to-vehicle (G2V) mode, and also in vehicle-to-grid (V2G) mode, transferring the battery energy to the grid when the vehicle is parked. The charger is controlled with a Perfect Harmonic Cancellation (PHC) strategy, contributing to improve the grid power quality, since the current demanded or injected has no harmonic content and a high power factor. Hall-effect current and voltage transducers have been used in the sensor stage to carry out this control strategy. Experimental results with a laboratory prototype are presented.

  20. Quality Control Activities Related to Mechanical Maintenance of Safety Related Components at Krsko NPP

    International Nuclear Information System (INIS)

    Djakovic, D.

    2016-01-01

    performing receipt control of complete units had found many deficiencies, excessive distortions, heat tints and corrosion spots. Heat tints could cause corrosion, which could accelerate in a harsh environment conditions. The reason for the faults identified in both cases was improper human performance. These findings confirm the need to control human performance factor in addition to standard quality control activities. Best tools to be used in such cases beside QC inspections are QNOD observations. The third specific maintenance case was a replacement of pressurizer spray control valve during the last outage. This was a complex activity on Safety Class 1 equipment. The QC department had to perform welding control and non-destructive examination of welds in very demanding radiological conditions. This activity affected the plant ISI program and pre-service inspection of the welds had to be performed. Activities affecting quality shall be accomplished under suitably controlled conditions and well performed maintenance of safety related components followed by successful QC control are essential for nuclear safety. (author).

  1. Implementation of DMLC quality control using EPID (Portal Dosimetry); Implementacao de um controle de qualidade de DMLC utilizando um EPID (Portal Dosimetry)

    Energy Technology Data Exchange (ETDEWEB)

    Mattos, Fabio R.; Furnari, Laura, E-mail: mattos.fr@gmail.com [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Faculdade de Medicina; Universidade de Sao Paulo (INRAD/HC/FMUSP), Sao Paulo, SP (Brazil). Instituto de Radiologia. Setor de Radioterapia

    2017-11-01

    A Quality Assurance (QA) to ensure the expected performance of a Multileaf Collimator System (MLC) is essential to deliver dose in a safety and appropriate way. The time required for equipment control and dosimetry may be reduced when the Electronic Portal Image Device (EPID) is used. The aim of this work was to check the resolution limits of the detection system for IMRT mode, and to propose a set of tests that can provide positioning analysis of a multileaf system. A Varian iX Clinac equipped with an 80 leaf Millenium MLC, and an amorphous silicon based EPID (aS1000) was used. The EPID proved itself effective for detecting errors up to 0.5 mm. The proposed tests provided relevant results of leaf position, and revealed that the MLC system is within acceptable limits found in literature. (author)

  2. Control by quality: proposition of a typology.

    Science.gov (United States)

    Pujo, P; Pillet, M

    The application of Quality tools and methods in industrial management has always had a fundamental impact on the control of production. It influences the behavior of the actors concerned, while introducing the necessary notions and formalizations, especially for production systems with little or no automation, which constitute a large part of the industrial activity. Several quality approaches are applied in the workshop and are implemented at the level of the control. In this paper, the authors present a typology of the various approaches that have successively influenced control, such as statistical process control, quality assurance, and continuous improvement. First the authors present a parallel between production control and quality organizational structure. They note the duality between control, which is aimed at increasing productivity, and quality, which aims to satisfy the needs of the customer. They also note the hierarchical organizational structure of these two systems of management with, at each level, the notion of a feedback loop. This notion is fundamental to any kind of decision making. The paper is organized around the operational, tactical, and strategic levels, by describing for each level the main methods and tools for control by quality. The overview of these tools and methods starts at the operational level, with the Statistical Process Control, the Taguchi technique, and the "six sigma" approach. On the tactical level, we find a quality system approach, with a documented description of the procedures introduced in the firm. The management system can refer here to Quality Assurance, Total Productive Maintenance, or Management by Total Quality. The formalization through procedures of the rules of decision governing the process control enhances the validity of these rules. This leads to the enhancement of their reliability and to their consolidation. All this counterbalances the human, intrinsically fluctuating, behavior of the control

  3. INFORMATION SYSTEM QUALITY CONTROL KNOWLEDGE

    Directory of Open Access Journals (Sweden)

    Vladimir Nikolaevich Babeshko

    2017-02-01

    Full Text Available The development of the educational system is associated with the need to control the quality of educational services. Quality control knowledge is an important part of the scientific process. The penetration of computers into all areas of activities changing approaches and technologies that previously they were used.

  4. Testing objects in Computerized Axial Tomography. Contributions to the Spanish Protocol on quality control in radiodiagnostics

    International Nuclear Information System (INIS)

    Villaescusa, J.I.; Campayo, J.M.

    1995-01-01

    In the provisional version of the Spanish Protocol about the technical aspects of Quality Control in Radiodiagnostic,SEFM-SEPR 1993, it is dedicated a section to Computerized Axial tomography, establishing a total of eleven technical parameters of the equipment for examination. The present work describes the practical use of the Protocol using various types of Test Object. The authors also propose new tests that should be considered in the final version of the Spanish Protocol. (Author)

  5. Quality assurance in central nuclear power plant control systems. (Status report containing proposed enhancements for KTA rules)

    International Nuclear Information System (INIS)

    Gossner, S.

    1985-01-01

    All enterprises investigated observe the requirements laid down in KTA 1401. In most cases, the quality assurance systems and measures applied even go beyond the requirements of KTA 1401, especially in those enterprises working primarily for export and having to meet foreign quality assurance standards. Quality assurance measures in these enterprises are based primarily on 10 CFR 50, App.B and related rules and standards (e.g. ANSI N 54.2; NUREG 75/087). Internal quality assurance in these enterprises is organized on the basis of graphic flow diagrams which are even presented in the quality assurance manuals. These flow diagrams, in contrast to the German KTA rules, meet the international standards for quality assurance. KTA 1401 requirements not sufficiently met are, e.g. the operator audits with plant producers and unit and equipment producer audits with component producers. The report presents hints for improvements of the quality assurance concept in control systems engineering. (orig./HP) [de

  6. Experiences of a secondary laboratory of dosimetric calibration from the radiation protection and hygiene center CPHR in its first year of work and the procedures for quality assessment used in the calibration and quality control service

    International Nuclear Information System (INIS)

    Morales, J.A.; Campa, R.; Jova Sed, L.

    1996-01-01

    Experiences of a secondary laboratory of dosimetric calibration from the Radiation Protection and Hygiene Center (CPHR) in first year of work and the procedures for quality assessment used in the calibration and quality control service of radiotherapeutic equipment. For the yield calibration of the calibrated sources an ionometric method was used using ionizing chambers coupled to electrometers. Those determination were based on dosimetric American Association of Physicists in Medicine (AAPM)

  7. Improved quality control of carbon-14 labelled compounds

    International Nuclear Information System (INIS)

    Leonhardt, J.W.; Fuchs, P.; Standtke, K.

    1997-01-01

    IUT Ltd is a producer of carbon-14 labelled organic compounds like benzene, methanol, phenol, formaldehyde, Na-acetates and also special ordered compounds. The quality control of these compounds is carried out by means of HPLC and GC-MS due to chemical purity. Molar activity was determined by Liquid Scintillation Counting and HPLC being equipped by a radioactivity detector. Unfortunately the accuracy of the activity determination was arrived only ±4% relatively. This error is too high because of the large dilution factors. In respect of the IUT accreditation as an analytical laboratory in Germany the accuracy had to be improved remarkably. Therefore the GC-MS-determination of molar activities of labelled compounds is used as the 14 C-labelled compound. A special evaluation code is used to determine the enrichment values relative to the unlabelled molecules. Taking into account the results of GC-MS the accuracy of molar activity determination is improved to ±2%. The spectra evaluation is demonstrated and some examples are discussed

  8. Determination and evaluation of air quality control. Manual of ambient air quality control in Germany

    Energy Technology Data Exchange (ETDEWEB)

    Lahmann, E.

    1997-07-01

    Measurement of air pollution emissions and ambient air quality are essential instruments for air quality control. By undertaking such measurements, pollutants are registered both at their place of origin and at the place where they may have an effect on people or the environment. Both types of measurement complement each other and are essential for the implementation of air quality legislation, particularly, in compliance with emission and ambient air quality limit values. Presented here are similar accounts of measurement principles and also contains as an Appendix a list of suitability-tested measuring devices which is based on information provided by the manufacturers. In addition, the guide of ambient air quality control contains further information on discontinuous measurement methods, on measurement planning and on the assessment of ambient air quality data. (orig./SR)

  9. Quality assessment of ultrasonographic equipment using an ATS-539 multipurpose phantom

    International Nuclear Information System (INIS)

    Kim, Pyo Nyun; Lim, Joo Won; Kim, Hyun Cheol; Yoon, Young Cheol; Sung, Deuk Je; Moon, Min Hoan; Kim, Jeong Sook; Kim, Jong Chan

    2008-01-01

    To determine the rate of congruence and to standardize assessment of US (ultrasound) phantom images with the use of an ATS-539 multipurpose phantom for US equipment currently utilized in Korea. US phantom images were scanned with a 3.0-5.0 MHz convex transducer and were digitized by use of an analogue-digital converter. Members of a committee with consent evaluated the US phantom images from 108 types of ultrasound equipment. The dead zone, vertical and horizontal measurement, axial/lateral resolution, focal zone, sensitivity, functional resolution and gray scale/dynamic range were evaluated. Congruence or incongruence of ultrasound equipment was determined based on the results of dead zone, axial/lateral resolution and gray scale/dynamic range measurements. Other factors were evaluated for the possibility as criteria with the use of the Mann-Whitney U test and receiver operator characteristic (ROC) curve analysis. The dead zone, axial/lateral resolution and gray scale/dynamic range were 91.7%, 94.4% and 76.9%, respectively, for suitable US equipment. Considering all three factors, 78 types of ultrasound equipment were passed. The congruence rate of focal zone and functional resolution were 62.4% and 69.3% of the US equipment, respectively. Of the US equipment, 72.2% of the equipment was acceptable based on the dead zone, axial/lateral resolution, and gray scale/dynamic range measurement as determined with the use of an ATS-539 phantom. Focal zone and 8 mm-functional resolution can be useful as a standard in the assessment of a US phantom image

  10. The Quality Control of Intensity Modulated Radiation Therapy (IMRT for ONCOR Siemens Linear Accelerators Using Film Dosimetry

    Directory of Open Access Journals (Sweden)

    Keyvan Jabbari

    2012-03-01

    Full Text Available Introduction Intensity Modulated Radiation Therapy (IMRT has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various steps of planning and quality control of Siemens linear accelerators for IMRT, using film dosimetry. This article in addition to review of the techniques, discusses the details of experiments and possible sources of errors which are not mentioned in the protocols and other references. Materials and Methods This project was carried out in Isfahan Milad hospital which has two Siemens ONCOR linear accelerators. Both accelerators are equipped with Multi-Leaf Collimators (MLC which enables us to perform IMRT delivery in the step-and-shoot method. The quality control consists of various experiments related to the sections of radiation therapy. In these experiments, the accuracy of some components such as treatment planning system, imaging device (CT, MLC, control system of accelerator, and stability of the output are evaluated. The dose verification is performed using film dosimetry method. The films were KODAK-EDR2, which were calibrated before the experiments. One of the important steps is the comparison of the calculated dose with planning system and the measured dose in experiments. Results The results of the experiments in various steps have been acceptable according to the standard protocols. The calibration of MLC and evaluation of the leakage through the leaves of MLC was performed by using the film dosimetry and visual check. In comparison with calculated and measured dose, more that 80% of the points have to be in agreement within 3% of the value. In our experiments, between 85 and 90% of the points had such an agreement with IMRT delivery. Conclusion

  11. 30 CFR 74.6 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control. 74.6 Section 74.6 Mineral... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and... DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.6 Quality...

  12. Quality assurance in nuclear medicine

    International Nuclear Information System (INIS)

    Paras, P.

    1978-01-01

    Quality assurance practices must be followed throughout the entire nuclear medicine process, from the initial decision to perform a particular procedure, through the interpretation and reporting of the results. The various parameters that can be defined and measured in each area must be monitored by quality control tests to assure the excellence of the total nuclear medicine process. The presentation will discuss each of the major areas of nuclear medicine quality control and their interaction as a part of the entire system. Quality control testing results and recommendations for measurements of radioactivity distribution will be described with emphasis on imaging equipment and dose calibrating instrumentation. The role of the health physicist in a quality assurance program will be stressed. (author)

  13. The performance of a prototype device designed to evaluate general quality parameters of X-ray equipment

    International Nuclear Information System (INIS)

    Murata, C.H.; Fernandes, D.C.; Lavínia, N.C.; Caldas, L.V.E; Pires, S.R; Medeiros, R.B.

    2014-01-01

    The performance of radiological equipment can be assessed using non-invasive methods and portable instruments that can analyze an X-ray beam with just one exposure. These instruments use either an ionization chamber or a state solid detector (SSD) to evaluate X-ray beam parameters. In Brazil, no such instruments are currently being manufactured; consequently, these instruments come at a higher cost to users due to importation taxes. Additionally, quality control tests are time consuming and impose a high workload on the X-ray tubes when evaluating their performance parameters. The assessment of some parameters, such as the half-value layer (HVL), requires several exposures; however, this can be reduced by using a SSD that requires only a single exposure. One such SSD uses photodiodes designed for high X-ray sensitivity without the use of scintillation crystals. This sensitivity allows one electron-hole pair to be created per 3.63 eV of incident energy, resulting in extremely high and stable quantum efficiencies. These silicon photodiodes operate by absorbing photons and generating a flow of current that is proportional to the incident power. The aim of this study was to show the response of the solid sensor PIN RD100A detector in a multifunctional X-ray analysis system that is designed to evaluate the average peak voltage (kVp), exposure time, and HVL of radiological equipment. For this purpose, a prototype board that uses four SSDs was developed to measure kVp, exposure time, and HVL using a single exposure. The reproducibility and accuracy of the results were compared to that of different X-ray beam analysis instruments. The kVp reproducibility and accuracy results were 2% and 3%, respectively; the exposure time reproducibility and accuracy results were 2% and 1%, respectively; and the HVL accuracy was ±2%. The prototype's methodology was able to calculate these parameters with appropriate reproducibility and accuracy. Therefore, the prototype can be considered

  14. Cost-benefit evaluation in a quality control programme for conventional radiodiagnosis

    International Nuclear Information System (INIS)

    Gallini, R.; Belletti, S.; Giugni, U.

    1985-01-01

    A comparison is being made between the cost of the staff and equipment in a quality control programme of conventional radiodiagnosis and the benefit obtained in the reduction of spoilt films and in the reduction of dose to patients and workers. For over two years the programme has followed a protocol verified on about 50 X-ray tubes, 25 radiological devices and four automatic processors. The present research, based on previous data, works on a limited but representative sample of radiological X-ray tubes and accessories. The control procedures are carried out periodically to improve and make constant the efficiency of the radiological devices. An evaluation of the cost of these procedures is made. In the meantime the dose to the patients undergoing radiodiagnostic examinations is evaluated by a transmission chamber. Comparison between the values obtained before and after the control enables the benefits to be evaluated. Rejection of radiographic films is evaluated before and after the control to obtain the cost reduction. During the one year control period, there were no variations in the technical characteristics of the personnel, in the operational procedures or in the work-load. (author)

  15. [Quality control in herbal supplements].

    Science.gov (United States)

    Oelker, Luisa

    2005-01-01

    Quality and safety of food and herbal supplements are the result of a whole of different elements as good manufacturing practice and process control. The process control must be active and able to individuate and correct all possible hazards. The main and most utilized instrument is the hazard analysis critical control point (HACCP) system the correct application of which can guarantee the safety of the product. Herbal supplements need, in addition to standard quality control, a set of checks to assure the harmlessness and safety of the plants used.

  16. Distributed sensor architecture for intelligent control that supports quality of control and quality of service.

    Science.gov (United States)

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-02-25

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  17. Distributed Sensor Architecture for Intelligent Control that Supports Quality of Control and Quality of Service

    Directory of Open Access Journals (Sweden)

    Jose-Luis Poza-Lujan

    2015-02-01

    Full Text Available This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS parameters and the optimization of control using Quality of Control (QoC parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS communication standard as proposed by the Object Management Group (OMG. As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  18. Quality assurance programme and responsibility

    International Nuclear Information System (INIS)

    Lee Peter

    2004-01-01

    The contents of this chapter are follows - Quality Control of Equipment and Facilities, Monitoring and Analysis of Film Reject Rate, Continuous Medical Education (CME), Audit of X-Ray Radiographs, General Principles, Good Image Criteria

  19. Towards a strengthening of inspections carried out on pressurised equipment and pipework..

    International Nuclear Information System (INIS)

    Noel, St.

    2010-01-01

    Following the fast presidential election, a major restructuring of the administrative landscape was set in motion. Tasks that historically were the responsibility of the Ministry of Industry are now carried out by the Ministry of Sustainable Development, which in particular is responsible for the whole policy to do with the prevention of technological risks. The General Directorate for the Prevention of Risks (Direction generale de la prevention des risques (DGPR)) of this ministry is now responsible for controlling technological risks, opening up new perspectives in terms of managing accidental risks and offering a new opportunity for an 'integrated' approach, making it possible to deal with an industrial installation in all its facets. Within the DGPR, the Office for the Safety of Industrial Equipment (bureau de la securite des equipements industriels (BSEI)) is responsible for the safety of pressurised equipment, as well as pipes carrying gas, inflammable liquids and chemical products. After a quick presentation of the inspections carried out on this equipment, issues to do with their safety will be dealt with and in particular: - the suitability of inspections carried out in the tight of faults that are likely to occur and develop in the structures; - control of ageing; - management of the quality of new equipment. (author)

  20. Quality control education in the community college

    Science.gov (United States)

    Greene, J. Griffen; Wilson, Steve

    1966-01-01

    This paper describes the Quality Control Program at Daytona Beach Junior College, including course descriptions. The program in quality control required communication between the college and the American Society for Quality Control (ASQC). The college has machinery established for certification of the learning process, and the society has the source of teachers who are competent in the technical field and who are the employers of the educational products. The associate degree for quality control does not have a fixed program, which can serve all needs, any more than all engineering degrees have identical programs. The main ideas which would be common to all quality control programs are the concept of economic control of a repetitive process and the concept of developing individual potentialities into individuals who are needed and productive.

  1. TRAINING SYSTEM OF FUTURE SPECIALISTS: QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    Vladimir A. Romanov

    2015-01-01

    Full Text Available The aim of the investigation is development of innovative strategy of quality control training of engineers and skilled workers (hereinafter – future specialists in educational professional organizations on the principles of social partnership.Methods. Theoretic: theoretic and methodological analysis, polytheoretic synthesis, modeling. Empirical: research and generalization of the system, process and competence – based approaches experience, experiment, observation, surveys, expert evaluation, SWOT-analysis as a method of strategic planning which is to identify the internal and external factors (socio-cultural of the organization surrounding.Results. The strategy of the development of the process of quality control training in educational professional organizations and a predictive model of the system of quality control training for future engineers and workers have been created on the analysis and synthesis of a quantitative specification of the quality, the obtained experience and success in control training of future specialists in educational professional organizations in recent economic and educational conditions.Scientific novelty. There has been built a predicative model of quality control training of future specialists to meet modern standards and the principles of social partnership; the control algorithm of the learning process, developed in accordance with the standards (international of quality ISO in the implementation of the quality control systems of the process approach (matrix-based responsibility, competence and remit of those responsible for the education process in the educational organization, the «problem» terms and diagnostic tools for assessing the quality of professional training of future specialists. The perspective directions of innovation in the control of the quality of future professionals training have been determined; the parameters of a comprehensive analysis of the state of the system to ensure the

  2. Effectiveness of mat Pilates or equipment-based Pilates in patients with chronic non-specific low back pain: a protocol of a randomised controlled trial

    Science.gov (United States)

    2013-01-01

    Background Chronic low back pain is an expensive and difficult condition to treat. One of the interventions widely used by physiotherapists in the treatment of chronic non-specific low back pain is exercise therapy based upon the Pilates principles. Pilates exercises can be performed with or without specific equipment. These two types of Pilates exercises have never been compared on a high-quality randomised controlled trial. Methods/design This randomised controlled trial with a blinded assessor will evaluate eighty six patients of both genders with chronic low back pain, aged between 18 and 60 years, from one Brazilian private physiotherapy clinic. The patients will be randomly allocated into two groups: Mat Group will perform the exercises on the ground while the Equipment-based Group will perform the Pilates method exercises on the following equipment: Cadillac, Reformer, Ladder Barrel, and Step Chair. The general and specific disability of the patient, kinesiophobia, pain intensity and global perceived effect will be evaluated by a blinded assessor before randomisation and at six weeks and six months after randomisation. In addition, the expectation of the participants and their confidence with the treatment will be evaluated before randomisation and after the first treatment session, respectively. Discussion This will be the first study aiming to compare the effectiveness of Mat and Equipment-based Pilates exercises in patients with chronic non-specific low back pain. The results may help health-care professionals in clinical decision-making and could potentially reduce the treatment costs of this condition. Trial registration Brazilian Registry of Clinical Trials RBR-7tyg5j PMID:23298183

  3. Exercise Equipment: Neutral Buoyancy

    Science.gov (United States)

    Shackelford, Linda; Valle, Paul

    2016-01-01

    Load Bearing Equipment for Neutral Buoyancy (LBE-NB) is an exercise frame that holds two exercising subjects in position as they apply counter forces to each other for lower extremity and spine loading resistance exercises. Resistance exercise prevents bone loss on ISS, but the ISS equipment is too massive for use in exploration craft. Integrating the human into the load directing, load generating, and motion control functions of the exercise equipment generates safe exercise loads with less equipment mass and volume.

  4. Computer aided process control equipment at the Karlsruhe reprocessing pilot plant, WAK

    International Nuclear Information System (INIS)

    Winter, R.; Finsterwalder, L.; Gutzeit, G.; Reif, J.; Stollenwerk, A.H.; Weinbrecht, E.; Weishaupt, M.

    1991-01-01

    A computer aided process control system has been installed at the Karlsruhe Spent Fuel Reprocessing Plant, WAK. All necessary process control data of the first extraction cycle is collected via a data collection system and is displayed in suitable ways on a screen for the operator in charge of the unit. To aid verification of displayed data, various measurements are associated to each other using balance type process modeling. Thus, deviation of flowsheet conditions and malfunctioning of measuring equipment are easily detected. (orig.) [de

  5. EQuIP-ped for Success

    Science.gov (United States)

    Ewing, Molly

    2015-01-01

    The Educators Evaluating the Quality of Instructional Products (EQuIP) Rubric for science is a new tool for science educators that provides criteria by which to examine the alignment and overall quality of lessons and units with respect to the "Next Generation Science Standards" ("NGSS"). The rubric criteria are divided into…

  6. 48 CFR 870.115 - Food service equipment.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Food service equipment... DEPARTMENT SUPPLEMENTARY REGULATIONS SPECIAL PROCUREMENT CONTROLS Controls 870.115 Food service equipment. (a) All new food service equipment purchased for Dietetic Service through other than Defense General...

  7. Process plant equipment operation, control, and reliability

    CERN Document Server

    Holloway, Michael D; Onyewuenyi, Oliver A

    2012-01-01

    "Process Plant Equipment Book is another great publication from Wiley as a reference book for final year students as well as those who will work or are working in chemical production plants and refinery…" -Associate Prof. Dr. Ramli Mat, Deputy Dean (Academic), Faculty of Chemical Engineering, Universiti Teknologi Malaysia "…give[s] readers access to both fundamental information on process plant equipment and to practical ideas, best practices and experiences of highly successful engineers from around the world… The book is illustrated throughout with numerous black & white p

  8. 14 CFR 145.211 - Quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...

  9. 18 CFR 12.40 - Quality control programs.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Quality control... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a... meeting any requirements or standards set by the Regional Engineer. If a quality control program is...

  10. Good manufacturing practice - quality assurance programs

    International Nuclear Information System (INIS)

    Masefield, John; Thompson, Steven

    1986-01-01

    The concept of good manufacturing practice (GMP) in the medical device industry requires the use of controlled methods and equipment in performing each step in the device manufacturing process. Quality assurance programs are used to maintain compliance with GMP requirements by prescribing the operating and control procedures to be used. The specific elements of a quality assurance program for the radiation sterilization of medical devices are described. (author)

  11. Developing methods of controlling quality costs

    Directory of Open Access Journals (Sweden)

    Gorbunova A. V.

    2017-01-01

    Full Text Available The article examines issues of managing quality costs, problems of applying economic methods of quality control, implementation of progressive methods of quality costs management in enterprises with the view of improving the efficiency of their evaluation and analysis. With the aim of increasing the effectiveness of the cost management mechanism, authors introduce controlling as a tool of deviation analysis from the standpoint of the process approach. A list of processes and corresponding evaluation criteria in the quality management system of enterprises is introduced. Authors also introduce the method of controlling quality costs and propose it for the practical application, which allows them to determine useful and unnecessary costs at the existing operating plant. Implementing the proposed recommendations in the system of cost management at an enterprise will allow to improve productivity of processes operating and reduce wasted expense on the quality of the process on the basis of determining values of useful and useless costs of quality according to criteria of processes functioning in the system of quality management.

  12. The application of nuclear equipment to measurement and control in the steel industry

    International Nuclear Information System (INIS)

    Van Schalkwyk, J.

    1976-01-01

    In this paper, some of the reasons for utilising equipment which makes use of nuclear radiation for the control of processes in the steel industry will be discussed. Two applications will be analysed to demonstrate the reasoning and to highlight some of the factors and principles [af

  13. Computer controlled quality of analytical measurements

    International Nuclear Information System (INIS)

    Clark, J.P.; Huff, G.A.

    1979-01-01

    A PDP 11/35 computer system is used in evaluating analytical chemistry measurements quality control data at the Barnwell Nuclear Fuel Plant. This computerized measurement quality control system has several features which are not available in manual systems, such as real-time measurement control, computer calculated bias corrections and standard deviation estimates, surveillance applications, evaluaton of measurement system variables, records storage, immediate analyst recertificaton, and the elimination of routine analysis of known bench standards. The effectiveness of the Barnwell computer system has been demonstrated in gathering and assimilating the measurements of over 1100 quality control samples obtained during a recent plant demonstration run. These data were used to determine equaitons for predicting measurement reliability estimates (bias and precision); to evaluate the measurement system; and to provide direction for modification of chemistry methods. The analytical chemistry measurement quality control activities represented 10% of the total analytical chemistry effort

  14. Employee quality, monitoring environment and internal control

    Directory of Open Access Journals (Sweden)

    Chunli Liu

    2017-03-01

    Full Text Available We investigate the effect of internal control employees (ICEs on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX, have higher institutional ownership or attach greater importance to internal control. Our findings suggest that ICEs play an important role in the design and implementation of internal control systems. Our study should be of interest to both top managers who wish to improve corporate internal control quality and regulators who wish to understand the mechanisms of internal control monitoring.

  15. Problems of quality assurance and quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Angerstein, W.

    1986-01-01

    Topical problems of quality assurance and quality control in diagnostic radiology are discussed and possible solutions are shown. Complex units are differentiated with reference to physicians, technicians, organization of labour, methods of examination and indication. Quality control of radiologic imaging systems should involve three stages: (1) simple tests carried out by radiologic technicians, (2) measurements by service technicians, (3) testing of products by the manufacturer and independent governmental or health service test agencies. (author)

  16. Quality Control in construction.

    Science.gov (United States)

    1984-01-01

    behavioral scientists. In 1962, Dr. Kaoru Ishikawa gave shape to the form of training which featured intradepartmental groups of ten or so workers seated...and Japanese circles bears closer scrutiny. 4.3.1 Japanese Ingredients of Quality The founder of quality circles, Dr. Kaoru Ishikawa , gives six...around 51 a table; hence the name Quality Control Circle. 4 Dr. 0 Ishikawa was an engineering professor at Tokyo University, and the circles were

  17. Metrological control of instruments, equipment and measurement system for ultrasonic meters of flow; Controle metrologico de instrumentos, equipamentos e sistema de medicao para medidores ultra-sonicos de vazao

    Energy Technology Data Exchange (ETDEWEB)

    Palacios, Oscar de

    2004-07-01

    Following the actual tendency to obtaining greater precision in Natural Gas measurement, in the past few years the use of Ultrasonic Flow Meters as Custody Transfer applications has grown significantly. There are several units currently operating in Brazil. The legislation for model approval, measure system certification and periodical metrological control of the above mentioned equipment, is currently under elaboration final stage. It was placed under public inquire through the 'Portaria 037' of 2004 of INMETRO, which proposes the authorization to perform the Metrological control by the Operator, once it has a quality system implemented according NBR ISO 9001-2000 and/or ISO 17025. This paper describes the verification procedure adopted by most of ultrasonic meters manufacturers. It also describes the application of the procedure for create the 'Metrological Control System of the Measurement System' of a 12'' Ultrasonic Meter installed and operating, with 3 years operation's data. (author)

  18. Establishment for quality control of experimental animal

    International Nuclear Information System (INIS)

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus

  19. Establishment for quality control of experimental animal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus.

  20. Quality assurance procedures in radiotherapy - IEC specifications for equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rassow, J; Klieber, E

    1986-08-01

    The International Electrotechnical Commission (IEC) worked out international standards for requirements and tests of electrical, mechanical and radiation safety as well as for definition and tests of functional performance characteristics of radiotherapy equipments (medical electron accelerators, gamma beam teletherapy and afterloading equipments, simulators and accessories) and for clinical dosimeters and terminology for medical radiology. A survey is given on the actual state of standardization projects. The problems of such standards are shown for the standard for functional performance characteristics of medical electron accelerators as example.

  1. Quality assurance procedures in radiotherapy - IEC specifications for equipment

    International Nuclear Information System (INIS)

    Rassow, J.; Klieber, E.

    1986-01-01

    The International Electrotechnical Commission (IEC) worked out international standards for requirements and tests of electrical, mechanical and radiation safety as well as for definition and tests of functional performance characteristics of radiotherapy equipments (medical electron accelerators, gamma beam teletherapy and afterloading equipments, simulators and accessories) and for clinical dosimeters and terminology for medical radiology. A survey is given on the actual state of standardization projects. The problems of such standards are shown for the standard for functional performance characteristics of medical electron accelerators as example. (orig.) [de

  2. Equipment line-up developed for structuring programmed digital systems important to safety

    International Nuclear Information System (INIS)

    Remus, L.; Colling, J.M.; Buisson, J.

    1986-01-01

    The use of the programmed digital techniques in systems important to safety led to developing equipment line-ups which allow to procedure, through using a restricted number of sub-assemblies, a variety of facilities capable of performing diversified functions. Upon remembering the requirements that such equipment are required to meet (quality assurance both at the design and production stages, qualification, testing opportunities, etc.) the equipments produced by MERLIN GERIN are described in this paper. Such equipments include a whole set of printed circuit boards, plug-in units with self-engaging connectors and the related cabinets to accomodate them. The following systems are made up of such equipments: Digital integrated protection system; Rod control and monitoring system; Reactor power distribution monitoring equipment. This equipment line-up has been gradually complemented and is still further expanding both as a result of the component further development or for the purpose of meeting new requirements or applications (new digital neutron instrumentation, local area networks). Experience gained thus far provides us with the capability of working out in a short time programmed systems for further applications in the nuclear power field

  3. Quality control for dose calibrators

    International Nuclear Information System (INIS)

    Mendes, L.C.G.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are accomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintillation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (author)

  4. Quality control for the first large areas of triple-GEM chambers for the CMS endcaps

    Science.gov (United States)

    Abbaneo, D.; Abbas, M.; Abbrescia, M.; Abi Akl, M.; Aboamer, O.; Acosta, D.; Ahmad, A.; Ahmed, W.; Aleksandrov, A.; Altieri, P.; Asawatangtrakuldee, C.; Aspell, P.; Assran, Y.; Awan, I.; Bally, S.; Ban, Y.; Banerjee, S.; Barashko, V.; Barria, P.; Bencze, G.; Beni, N.; Benussi, L.; Bhopatkar, V.; Bianco, S.; Bos, J.; Bouhali, O.; Braghieri, A.; Braibant, S.; Buontempo, S.; Calabria, C.; Caponero, M.; Caputo, C.; Cassese, F.; Castaneda, A.; Cauwenbergh, S.; Cavallo, F. R.; Celik, A.; Choi, M.; Choi, S.; Christiansen, J.; Cimmino, A.; Colafranceschi, S.; Colaleo, A.; Conde Garcia, A.; Czellar, S.; Dabrowski, M. M.; De Lentdecker, G.; De Oliveira, R.; de Robertis, G.; Dildick, S.; Dorney, B.; Endroczi, G.; Errico, F.; Fenyvesi, A.; Ferry, S.; Furic, I.; Giacomelli, P.; Gilmore, J.; Golovtsov, V.; Guiducci, L.; Guilloux, F.; Gutierrez, A.; Hadjiiska, R. M.; Hauser, J.; Hoepfner, K.; Hohlmann, M.; Hoorani, H.; Iaydjiev, P.; Jeng, Y. G.; Kamon, T.; Karchin, P.; Korytov, A.; Krutelyov, S.; Kumar, A.; Kim, H.; Lee, J.; Lenzi, T.; Litov, L.; Loddo, F.; Madorsky, A.; Maerschalk, T.; Maggi, M.; Magnani, A.; Mal, P. K.; Mandal, K.; Marchioro, A.; Marinov, A.; Majumdar, N.; Merlin, J. A.; Mitselmakher, G.; Mohanty, A. K.; Mohapatra, A.; Molnar, J.; Muhammad, S.; Mukhopadhyay, S.; Naimuddin, M.; Nuzzo, S.; Oliveri, E.; Pant, L. M.; Paolucci, P.; Park, I.; Passeggio, G.; Pavlov, B.; Philipps, B.; Piccolo, D.; Postema, H.; Puig Baranac, A.; Radi, A.; Radogna, R.; Raffone, G.; Ranieri, A.; Rashevski, G.; Riccardi, C.; Rodozov, M.; Rodrigues, A.; Ropelewski, L.; RoyChowdhury, S.; Ryu, G.; Ryu, M. S.; Safonov, A.; Salva, S.; Saviano, G.; Sharma, A.; Sharma, A.; Sharma, R.; Shah, A. H.; Shopova, M.; Sturdy, J.; Sultanov, G.; Swain, S. K.; Szillasi, Z.; Talvitie, J.; Tatarinov, A.; Tuuva, T.; Tytgat, M.; Vai, I.; Van Stenis, M.; Venditti, R.; Verhagen, E.; Verwilligen, P.; Vitulo, P.; Volkov, S.; Vorobyev, A.; Wang, D.; Wang, M.; Yang, U.; Yang, Y.; Yonamine, R.; Zaganidis, N.; Zenoni, F.; Zhang, A.

    2018-02-01

    The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC. This project is at the final stages of R&D and moving to production. An unprecedented large area of several 100 m2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators.

  5. Quality control for the first large areas of triple-GEM chambers for the CMS endcaps

    Directory of Open Access Journals (Sweden)

    Abbaneo D.

    2018-01-01

    Full Text Available The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC. This project is at the final stages of R&D and moving to production. An unprecedented large area of several 100 m2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators.

  6. Quality control for the first large areas of triple-GEM chambers for the CMS endcaps

    CERN Document Server

    AUTHOR|(CDS)2068936; Abbas, M.; Abbrescia, M.; Abi Akl, M.; Aboamer, O.; Acosta, D.; Ahmad, A.; Ahmed, W.; Aleksandrov, A.; Altieri, P.; Asawatangtrakuldee, C.; Aspell, P.; Assran, Y.; Awan, I.; Bally, S.; Ban, Y.; Banerjee, S.; Barashko, V.; Barria, P.; Bencze, G.; Beni, N.; Benussi, L.; Bhopatkar, V.; Bianco, S.; Bos, J.; Bouhali, O.; Braghieri, A.; Braibant, S.; Buontempo, S.; Calabria, C.; Caponero, M.; Caputo, C.; Cassese, F.; Castaneda, A.; Cauwenbergh, S.; Cavallo, F.R.; Celik, A.; Choi, M.; Choi, S.; Christiansen, J.; Cimmino, A.; Colafranceschi, S.; Colaleo, A.; Conde Garcia, A.; Czellar, S.; Dabrowski, M.M.; De Lentdecker, G.; De Oliveira, R.; de Robertis, G.; Dildick, S.; Dorney, B.; Endroczi, G.; Errico, F.; Fenyvesi, A.; Ferry, S.; Furic, I.; Giacomelli, P.; Gilmore, J.; Golovtsov, V.; Guiducci, L.; Guilloux, F.; Gutierrez, A.; Hadjiiska, R.M.; Hauser, J.; Hoepfner, K.; Hohlmann, M.; Hoorani, H.; Iaydjiev, P.; Jeng, Y.G.; Kamon, T.; Karchin, P.; Korytov, A.; Krutelyov, S.; Kumar, A.; Kim, H.; Lee, J.; Lenzi, T.; Litov, L.; Loddo, F.; Madorsky, A.; Maerschalk, T.; Maggi, M.; Magnani, A.; Mal, P.K.; Mandal, K.; Marchioro, A.; Marinov, A.; Majumdar, N.; Merlin, J.A.; Mitselmakher, G.; Mohanty, A.K.; Mohapatra, A.; Molnar, J.; Muhammad, S.; Mukhopadhyay, S.; Naimuddin, M.; Nuzzo, S.; Oliveri, E.; Pant, L.M.; Paolucci, P.; Park, I.; Passeggio, G.; Pavlov, B.; Philipps, B.; Piccolo, D.; Postema, H.; Puig Baranac, A.; Radi, A.; Radogna, R.; Raffone, G.; Ranieri, A.; Rashevski, G.; Riccardi, C.; Rodozov, M.; Rodrigues, A.; Ropelewski, L.; RoyChowdhury, S.; Ryu, G.; Ryu, M.S.; Safonov, A.; Salva, S.; Saviano, G.; Sharma, A.; Sharma, A.; Sharma, R.; Shah, A.H.; Shopova, M.; Sturdy, J.; Sultanov, G.; Swain, S.K.; Szillasi, Z.; Talvitie, J.; Tatarinov, A.; Tuuva, T.; Vai, I.; Van Stenis, M.; Venditti, R.; Verhagen, E.; Verwilligen, P.; Vitulo, P.; Volkov, S.; Vorobyev, A.; Wang, D.; Wang, M.; Yang, U.; Yang, Y.; Yonamine, R.; Zaganidis, N.; Zenoni, F.; Zhang, A.

    2015-01-01

    The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC. This project is at the final stages of R&D and moving to production. An unprecedented large area of several 100 m2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators.

  7. Performance of mechanical ventilators at the patient's home: a multicentre quality control study.

    Science.gov (United States)

    Farré, R; Navajas, D; Prats, E; Marti, S; Guell, R; Montserrat, J M; Tebe, C; Escarrabill, J

    2006-05-01

    Quality control procedures vary considerably among the providers of equipment for home mechanical ventilation (HMV). A multicentre quality control survey of HMV was performed at the home of 300 patients included in the HMV programmes of four hospitals in Barcelona. It consisted of three steps: (1) the prescribed ventilation settings, the actual settings in the ventilator control panel, and the actual performance of the ventilator measured at home were compared; (2) the different ventilator alarms were tested; and (3) the effect of differences between the prescribed settings and the actual performance of the ventilator on non-programmed readmissions of the patient was determined. Considerable differences were found between actual, set, and prescribed values of ventilator variables; these differences were similar in volume and pressure preset ventilators. The percentage of patients with a discrepancy between the prescribed and actual measured main ventilator variable (minute ventilation or inspiratory pressure) of more than 20% and 30% was 13% and 4%, respectively. The number of ventilators with built in alarms for power off, disconnection, or obstruction was 225, 280 and 157, respectively. These alarms did not work in two (0.9%), 52 (18.6%) and eight (5.1%) ventilators, respectively. The number of non-programmed hospital readmissions in the year before the study did not correlate with the index of ventilator error. This study illustrates the current limitations of the quality control of HMV and suggests that improvements should be made to ensure adequate ventilator settings and correct ventilator performance and ventilator alarm operation.

  8. Fuel quality control: Five years of activity in laboratories

    International Nuclear Information System (INIS)

    Bettinelli, M.; Cimini, G.; Durello, G.; Lucchesi, P.L.

    1991-01-01

    A description of how ENEL (Italian National Electricity Board) carries out the activity of fuel quality control is given, and the results of the Round Robin circuit which has been operating for five years in laboratories regulary performing the control analyses of these products are reported. The laboratories taking part in the Round Robin circuit are 41 (out of which 35 are ENEL laboratories and 6 are owned by external companies) and they are situated throughout Italy; the controlled parameters are the following: heat of combustion (PCS), sulphur (S), vanadium (V) and asphaltenes (ASF); the adopted methods are the official ASTM or IP ones. The statistical analysis of the results has permitted, for every parameter, the calculation of the repeatability and the reproducibility which, in most cases, have turned out to be in keeping with the values provided for in the regulations. Among the collateral initiatives promoted in the framework of this Round Robin, the following are reported: preparation of standards of fuel oil with a known content of a sulphur and vanadium; expediting visits to all the ENEL laboratories participating in the RRT; publication of a handbook of the adopted analysis methods (in Italian); definition of guide-lines on the right selection of new automatic equipment

  9. Integrated reliability condition monitoring and maintenance of equipment

    CERN Document Server

    Osarenren, John

    2015-01-01

    Consider a Viable and Cost-Effective Platform for the Industries of the Future (IOF) Benefit from improved safety, performance, and product deliveries to your customers. Achieve a higher rate of equipment availability, performance, product quality, and reliability. Integrated Reliability: Condition Monitoring and Maintenance of Equipment incorporates reliable engineering and mathematical modeling to help you move toward sustainable development in reliability condition monitoring and maintenance. This text introduces a cost-effective integrated reliability growth monitor, integrated reliability degradation monitor, technological inheritance coefficient sensors, and a maintenance tool that supplies real-time information for predicting and preventing potential failures of manufacturing processes and equipment. The author highlights five key elements that are essential to any improvement program: improving overall equipment and part effectiveness, quality, and reliability; improving process performance with maint...

  10. Quality assurance for external radiotherapy equipment in Japan

    International Nuclear Information System (INIS)

    Tomaru, Teizo

    1993-01-01

    In Japan, quality assurance (QA) for external beam teletherapy equipment is carried out according to QA protocols issued by the Japanese Society for Therapeutic Radiology and Oncology (JASTRO), which are modified from the IEC recommendations. The QA program in Japan is introduced in this paper. It is advisable to do several tests daily, including the accuracy of the optical distance indicator, alignment of the sidelight, check of 10 x 10 cm light field, and constancy of the dose monitor. Pencil marks on the wall and floor can be used to check light alignment. Dose monitor calibration and flatness/symmetry should be checked weekly. Monthly tests should include 8 items: depth dose characteristics of electron beam, radiation-light field congruence, indication of x-ray beam axis (patient entry and exit), indication of isocenter, distance indicator, and vertical movement of table. Film is used to test the flatness/symmetry, and congruence of the radiation and light field. The alignment of the intersection of the cross hair is useful to check the x-ray beam axis indication and vertical movement of table. Checks of stability of each dose monitor system and mechanical alignment should be performed every 6 months or annually. Mechanical alignment is fundamentally important for the performance of a teletherapy unit. As a constancy check of the overall system, a split-field test is recommended due to its rapid and simple execution. (author)

  11. Training courses for radiological technicians: radiation protection of the patient and control of image quality

    International Nuclear Information System (INIS)

    Mateus Yoshimura, Elisabeth; Costa, Paulo Roberto; Furquim, Tania Aparecida; Freitas, Marcelo Baptista de; Valente, Marcelo; Cerri, Giovanni Guido

    2008-01-01

    Full text: As in other countries, life expectancy is increasing in Brazil, and the number of radiological examinations tends to increase. Old equipment and high technology ones cohabit, radiology technicians are not well prepared to conduct practices, images and doses to patients are not optimized. Digital techniques that began to be introduced in the last years are also an important issue, because, as it is possible to modify the image digitally, there is less concern about the choice of equipment parameters that produce the best-image/lowest-dose compromise. Pediatric radiology, CT and fluoroscopy require attention too, as they are of dosimetric interest or because the patient ages imply higher risks or because the techniques deliver higher doses than the conventional ones. In our opinion, the most important role that we can play is educating and forming people to work in this area: training programs and refreshing courses are a way of facing the problem. This way, we are organizing, in a technical cooperation with IAEA, two training courses in quality assurance and radiation protection in radiology, one designed to physicists (60 h), and the radiological technicians (40 h). An important cooperation with a paediatric and a general hospital made it possible to offer courses with 50% practical lessons, performed both in the University and in hospital equipment. Both courses cover a basic Radiation Physics program, radiation protection, image formation and quality control in conventional and digital equipment, and patient dosimetry. Equipment donated by IAEA facilitate the practical QA and dosimetry lessons. The rationale of our project is making it sustainable through the formation of physicists that will go on in the education process of technicians in technical schools. We present the results of the first two courses (physicists and technicians), considering the selection process, the development of the activities, and the assessment both of the students enrolled

  12. 42 CFR 84.256 - Quality control requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  13. Recent Progress toward Microfluidic Quality Control Testing of Radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    Noel S. Ha

    2017-11-01

    Full Text Available Radiopharmaceuticals labeled with short-lived positron-emitting or gamma-emitting isotopes are injected into patients just prior to performing positron emission tomography (PET or single photon emission tomography (SPECT scans, respectively. These imaging modalities are widely used in clinical care, as well as in the development and evaluation of new therapies in clinical research. Prior to injection, these radiopharmaceuticals (tracers must undergo quality control (QC testing to ensure product purity, identity, and safety for human use. Quality tests can be broadly categorized as (i pharmaceutical tests, needed to ensure molecular identity, physiological compatibility and that no microbiological, pyrogenic, chemical, or particulate contamination is present in the final preparation; and (ii radioactive tests, needed to ensure proper dosing and that there are no radiochemical and radionuclidic impurities that could interfere with the biodistribution or imaging. Performing the required QC tests is cumbersome and time-consuming, and requires an array of expensive analytical chemistry equipment and significant dedicated lab space. Calibrations, day of use tests, and documentation create an additional burden. Furthermore, in contrast to ordinary pharmaceuticals, each batch of short-lived radiopharmaceuticals must be manufactured and tested within a short period of time to avoid significant losses due to radioactive decay. To meet these challenges, several efforts are underway to develop integrated QC testing instruments that automatically perform and document all of the required tests. More recently, microfluidic quality control systems have been gaining increasing attention due to vastly reduced sample and reagent consumption, shorter analysis times, higher detection sensitivity, increased multiplexing, and reduced instrumentation size. In this review, we describe each of the required QC tests and conventional testing methods, followed by a

  14. Development of a standard operating procedure for mammography equipment used in calibration of ionized chambers

    International Nuclear Information System (INIS)

    Rodrigues, Yklys Santos; Potiens, Maria da Penha Albuquerque

    2011-01-01

    Mammography is one widely used technique in the detection of breast cancer. In order to optimize the results achieving better images with lower dose rates, a quality assurance programme must be applied to the equipment. Some control tests use ionization chambers to measure air kerma and other quantities. These tests can only be reliable if the ionization chambers used on them are correctly calibrated. In the present work, it was developed a standard operating procedure (SOP) for quality control tests in a commercial mammography equipment installed in the Calibration Laboratory (LCI) at IPEN - Brazilian Institute for energy and nuclear research). Seven tests were performed in the equipment: Tube voltage and exposition time accuracy and reproducibility, linearity and reproducibility of Air kerma and Half Value Layer (HVL). Then, it was made a measurement of the air kerma in the mammography equipment, using a reference ionization chamber with traceability to a primary laboratory in Germany (Physikalisch-Technische Bundesanstalt - PTB), that was later compared with the air kerma measured in an industrial irradiator. This industrial X-ray generator was recently used in the implementation of X-radiation Standards beams, mammography level, following the Standard IEC 61267. The HVL values varied from 0.36 (25kV) to 0.41 mmA1 (35kV), and the measured air kerma rates were between 9.78 and 17.97 mGy/min. (author)

  15. Methodology for the construction of a physical phantom for quality control of images in digital radiography

    International Nuclear Information System (INIS)

    Santos, Tayline T.; Vieira, Jose Wilson; Oliveira, Alex Cristovao H. de; Lima, Fernando R. de Andrade

    2013-01-01

    The advancement of technology in recent years has provided the production of increasingly sophisticated devices, aiming to acquire medical images with high technical level and also facilitate the operational readiness of the equipment. In order to ensure the most accurate diagnosis with minimum dose without exposing patients to obtain data and verify the performance of a radiographic system for quality control purposes we use the so-called phantoms. Phantoms are physical or computational models used to simulate the transport of ionizing radiation, their interactions in the tissues of the human body and evaluate the deposition of energy. Besides, they are made from materials with behavior similar to human tissues when exposed to ionizing radiation - the so-called tissue-equivalent materials. This paper describes the construction of a physical phantom that allows the execution of the main acceptance tests of the quality control protocols in digital radiography

  16. Medical equipment in government health facilities: Missed opportunities

    OpenAIRE

    Pardeshi Geeta

    2005-01-01

    BACKGROUND: The availability and optimal utilization of medical equipment is important for improving the quality of health services. Significant investments are made for the purchase, maintenance and repair of medical equipment. Inadequate management of these equipment will result in financial losses and deprive the public of the intended benefits. This analysis is based on the conceptual framework drawn from the WHO recommended- lifecycle of medical equipment. AIMS: (1) To identify the probl...

  17. Control protocol: the proposed new CERN standard access procedure to accelerator equipment

    International Nuclear Information System (INIS)

    Baribaud, G.; Barnett, I.; Benincasa, G.

    1992-01-01

    Control protocol provides a normalized access procedure for equipment of the same kind from a control system. Modelisation and the subsequent identification of functionalities with their parameters, variables and attributes have now been carried out at CERN for representative families of devices. ISO specifications, such as the ASN.1 metalanguage for data structure representation and MMS definitions and services have, to some extent, been introduced in the design for generality and compatibility with external world. The final product of this design is totally independent of the control systems and permits object oriented implementations in any controls frame. The present paper describes the different phases of the project with a short overview of the various implementations under development at CERN. (author)

  18. Quality assurance in diagnostic radiology - assessing the fluoroscopic image quality

    International Nuclear Information System (INIS)

    Tabakov, S.

    1995-01-01

    The X-ray fluoroscopic image has a considerably lower resolution than the radiographic one. This requires a careful quality control aiming at optimal use of the fluoroscopic equipment. The basic procedures for image quality assessment of Image Intensifier/TV image are described. Test objects from Leeds University (UK) are used as prototypes. The results from examining 50 various fluoroscopic devices are shown. Their limiting spatial resolution varies between 0.8 lp/mm (at maximum II field size) and 2.24 lp/mm (at minimum field size). The mean value of the limiting spatial resolution for a 23 cm Image Intensifier is about 1.24 lp/mm. The mean limits of variation of the contrast/detail diagram for various fluoroscopic equipment are graphically expressed. 14 refs., 1 fig. (author)

  19. Power quality improvement by using STATCOM control scheme in wind energy generation interface to grid

    Science.gov (United States)

    Kirmani, Sheeraz; Kumar, Brijesh

    2018-01-01

    “Electric Power Quality (EPQ) is a term that refers to maintaining the near sinusoidal waveform of power distribution bus voltages and currents at rated magnitude and frequency”. Today customers are more aware of the seriousness that the power quality possesses, this prompt the utilities to assure good quality of power to their customer. The power quality is basically customer centric. Increased focus of utilities toward maintaining reliable power supply by employing power quality improvement tools has reduced the power outages and black out considerably. Good power quality is the characteristic of reliable power supply. Low power factor, harmonic pollution, load imbalance, fast voltage variations are some common parameters which are used to define the power quality. If the power quality issues are not checked i.e. the parameters that define power quality doesn't fall within the predefined standards than it will lead into high electricity bill, high running cost in industries, malfunctioning of equipments, challenges in connecting renewable. Capacitor banks, FACTS devices, harmonic filters, SVC’s (static voltage compensators), STATCOM (Static-Compensator) are the solutions to achieve the power quality. The performance of Wind turbine generators is affected by poor quality power, at the same time these wind power generating plant affects the power quality negatively. This paper presents the STATCOM-BESS (battery energy storage system) system and studies its impact on the power quality in a system which consists of wind turbine generator, non linear load, hysteresis controller for controlling the operation of STATCOM and grid. The model is simulated in the MATLAB/Simulink. This scheme mitigates the power quality issues, improves voltage profile and also reduces harmonic distortion of the waveforms. BESS level out the imbalances caused in real power due to intermittent nature of wind power available due to varying wind speeds.

  20. Welding technologies for nuclear machinery and equipment

    International Nuclear Information System (INIS)

    Kobayashi, Masahiro; Yokono, Tomomi.

    1991-01-01

    The main welding methods applied to nuclear machinery and equipment are shielded metal arc welding, submerged arc welding, MAG welding and TIG welding. But in the last 10 years, in order to improve the reliability required for the welding of nuclear machinery and equipment, the welding technologies aiming at the reduction of heat input, the decrease of the number of welding pass and the automatic control of welding factors have been applied for the main purpose of bettering the quality and excluding human errors. The merits and the technology of narrow gap, pulsed MAG welding and melt-through welding are explained. As the automation of TIG welding, image processing type narrow gap, hot wire TIG welding and remote control type automatic TIG welding are described. For the longitudinal welding of active metal sheet products, plasma key-hole welding is applied. Since the concentration of its arc is good, high speed welding with low heat input can be done. For the stainless steel cladding by welding, electroslag welding has become to be employed in place of conventional submerged arc welding. Arc is not generated in the electroslag welding, and the penetration into base metal is small. (K.I.)