WorldWideScience

Sample records for equipment performance reliability

  1. Reliability performance of standby equipment with periodic testing

    International Nuclear Information System (INIS)

    Sim, S.H.

    1985-11-01

    In this report, the reliability performance of standby equipment subjected to periodic testing is studied. analytical expressions have been derived for reliability measures, such as the man accumulated operating time to failure, the expected number of tests between two consecutive failures, the mean time to failure following an emergency start-up and the probability of failing to complete an emergency mission of a specified duration. These results are useful for the reliability assessment of standby equipment such as combustion turbine units of the emergency power supply system, and of the Class III power system at a nuclear generating station

  2. Human performance for the success of equipment reliability programs

    International Nuclear Information System (INIS)

    Woodcock, J.

    2007-01-01

    Human performance is a critical element of programs directed at equipment reliability. Reliable equipment performance requires broad support from all levels of plant management and throughout all plant departments. Experience at both nuclear power plants and fuel manufacturing plants shows that human performance must be addressed during all phases of program implementation from the beginning through the establishment of a living, on-going process. At the beginning, certain organizational and management actions during the initiation of the program set the stage for successful adoption by station personnel, leading to more rapid benefits. For the long term, equipment reliability is a living process needed throughout the lifetime of a station, a program which must be motivated and measured. Sustained acceptance and participation by the plant personnel is a requirement, and culture is a key ingredient. This paper will provide an overview of key human performance issues to be considered, using the application of the INPO AP-913 Equipment Reliability Guideline as a basis and gives some best practices for training, communicating and implementing programs. The very last part includes ways to tell if the program is effective

  3. Assessment of Equipment Capability to Perform Reliably under Severe Accident Conditions

    International Nuclear Information System (INIS)

    2017-07-01

    The experience from the last 40 years has shown that severe accidents can subject electrical and instrumentation and control (I&C) equipment to environmental conditions exceeding the equipment’s original design basis assumptions. Severe accident conditions can then cause rapid degradation or damage to various degrees up to complete failure of such equipment. This publication provides the technical basis to consider when assessing the capability of electrical and I&C equipment to perform reliably during a severe accident. It provides examples of calculation tools to determine the environmental parameters as well as examples and methods that Member States can apply to assess equipment reliability.

  4. Analysis of performance reliability of electrical and electronic equipment of car-tractor

    Directory of Open Access Journals (Sweden)

    Kravchenko О.Р.

    2016-08-01

    Full Text Available The analysis of the operational reliability of electrical and electronic equipment of vehicles, trucks Mercedes-Benz Actros 1844 LS and Volvo FH 1242, conducting international cargo transportation is performed. It is established that the equipment is reliable, which meets modern requirements, but where there is a violation of the resolution. The reason for repair work is constructive and operational factors. Distribution of efficiency and overall performance of operational reliability is retrieved. Items with more bounce are found. Common factors of violation of efficiency cars, trucks in operation, are largely different stages in warranty runs are obtained.

  5. Equipment Reliability Program in NPP Krsko

    International Nuclear Information System (INIS)

    Skaler, F.; Djetelic, N.

    2006-01-01

    Operation that is safe, reliable, effective and acceptable to public is the common message in a mission statement of commercial nuclear power plants (NPPs). To fulfill these goals, nuclear industry, among other areas, has to focus on: 1 Human Performance (HU) and 2 Equipment Reliability (EQ). The performance objective of HU is as follows: The behaviors of all personnel result in safe and reliable station operation. While unwanted human behaviors in operations mostly result directly in the event, the behavior flaws either in the area of maintenance or engineering usually cause decreased equipment reliability. Unsatisfied Human performance leads even the best designed power plants into significant operating events, which can be found as well-known examples in nuclear industry. Equipment reliability is today recognized as the key to success. While the human performance at most NPPs has been improving since the start of WANO / INPO / IAEA evaluations, the open energy market has forced the nuclear plants to reduce production costs and operate more reliably and effectively. The balance between these two (opposite) goals has made equipment reliability even more important for safe, reliable and efficient production. Insisting on on-line operation by ignoring some principles of safety could nowadays in a well-developed safety culture and human performance environment exceed the cost of electricity losses. In last decade the leading USA nuclear companies put a lot of effort to improve equipment reliability primarily based on INPO Equipment Reliability Program AP-913 at their NPP stations. The Equipment Reliability Program is the key program not only for safe and reliable operation, but also for the Life Cycle Management and Aging Management on the way to the nuclear power plant life extension. The purpose of Equipment Reliability process is to identify, organize, integrate and coordinate equipment reliability activities (preventive and predictive maintenance, maintenance

  6. Scyllac equipment reliability analysis

    International Nuclear Information System (INIS)

    Gutscher, W.D.; Johnson, K.J.

    1975-01-01

    Most of the failures in Scyllac can be related to crowbar trigger cable faults. A new cable has been designed, procured, and is currently undergoing evaluation. When the new cable has been proven, it will be worked into the system as quickly as possible without causing too much additional down time. The cable-tip problem may not be easy or even desirable to solve. A tightly fastened permanent connection that maximizes contact area would be more reliable than the plug-in type of connection in use now, but it would make system changes and repairs much more difficult. The balance of the failures have such a low occurrence rate that they do not cause much down time and no major effort is underway to eliminate them. Even though Scyllac was built as an experimental system and has many thousands of components, its reliability is very good. Because of this the experiment has been able to progress at a reasonable pace

  7. Equipment Reliability Process in Krsko NPP

    International Nuclear Information System (INIS)

    Gluhak, M.

    2016-01-01

    To ensure long-term safe and reliable plant operation, equipment operability and availability must also be ensured by setting a group of processes to be established within the nuclear power plant. Equipment reliability process represents the integration and coordination of important equipment reliability activities into one process, which enables equipment performance and condition monitoring, preventive maintenance activities development, implementation and optimization, continuous improvement of the processes and long term planning. The initiative for introducing systematic approach for equipment reliability assuring came from US nuclear industry guided by INPO (Institute of Nuclear Power Operations) and by participation of several US nuclear utilities. As a result of the initiative, first edition of INPO document AP-913, 'Equipment Reliability Process Description' was issued and it became a basic document for implementation of equipment reliability process for the whole nuclear industry. The scope of equipment reliability process in Krsko NPP consists of following programs: equipment criticality classification, preventive maintenance program, corrective action program, system health reports and long-term investment plan. By implementation, supervision and continuous improvement of those programs, guided by more than thirty years of operating experience, Krsko NPP will continue to be on a track of safe and reliable operation until the end of prolonged life time. (author).

  8. Deep Space Network equipment performance, reliability, and operations management information system

    Science.gov (United States)

    Cooper, T.; Lin, J.; Chatillon, M.

    2002-01-01

    The Deep Space Mission System (DSMS) Operations Program Office and the DeepSpace Network (DSN) facilities utilize the Discrepancy Reporting Management System (DRMS) to collect, process, communicate and manage data discrepancies, equipment resets, physical equipment status, and to maintain an internal Station Log. A collaborative effort development between JPL and the Canberra Deep Space Communication Complex delivered a system to support DSN Operations.

  9. Integrated reliability condition monitoring and maintenance of equipment

    CERN Document Server

    Osarenren, John

    2015-01-01

    Consider a Viable and Cost-Effective Platform for the Industries of the Future (IOF) Benefit from improved safety, performance, and product deliveries to your customers. Achieve a higher rate of equipment availability, performance, product quality, and reliability. Integrated Reliability: Condition Monitoring and Maintenance of Equipment incorporates reliable engineering and mathematical modeling to help you move toward sustainable development in reliability condition monitoring and maintenance. This text introduces a cost-effective integrated reliability growth monitor, integrated reliability degradation monitor, technological inheritance coefficient sensors, and a maintenance tool that supplies real-time information for predicting and preventing potential failures of manufacturing processes and equipment. The author highlights five key elements that are essential to any improvement program: improving overall equipment and part effectiveness, quality, and reliability; improving process performance with maint...

  10. Performance monitoring of safeguards equipment

    International Nuclear Information System (INIS)

    Sirisena, K.; Peltoranta, M.; Goussarov, V.; Vodrazka, P.

    1999-01-01

    SGTCS is responsible for monitoring and reporting the performance of the SG equipment. Performance monitoring (PM) has been implemented in most important safeguards equipment operating unattended in nuclear facilities. Inspectors acquire equipment performance data in facilities. After inspection, the data package is submitted to SGTCS for processing and analysis. The performance data is used for identification of systems or components, which should be changed in the field and for identification of modules which, should be diagnosed at HQ in order to determine the cause of failure. Moreover, the performance data is used for preventive maintenance and spares distribution planning, and to provide statistics for official reports and management decision making. An important part of the performance monitoring is reporting. Equipment performance reports contain information about equipment inventory, utilization, failure types, failure distribution, and reliability. Trends in performance are given in graphical form in cases, where past data is available. Reliability estimates such as expected times between failures are provided. The automated reporting tools are obtainable through EMIS database application. (author)

  11. Maintenance optimization plan for essential equipment reliability

    International Nuclear Information System (INIS)

    Steffen, D.H.

    1996-02-01

    The Maintenance Optimization Plan (MOP) for Essential Equipment Reliability will furnish Tank Waste Remediation System (TWRS) management with a pro-active, forward-thinking process for maintaining essential structures, systems, and components (ESSC) at the Hanford Site tank farms in their designed condition, and to ensure optimum ESSC availability and reliability

  12. OREDA offshore and onshore reliability data volume 1 - topside equipment

    CERN Document Server

    OREDA

    2015-01-01

    This handbook presents high quality reliability data for offshore equipment collected during phase VI to IX (project period 2000 – 2009) of the OREDA project. The intention of the handbook is to provide both quantitative and qualitative information as a basis for Performance Forecasting or RAMS (Reliability, Availability, Maintainability and Safety) analyses. Volume 1 is about Topside Equipment. Compared to earlier editions, there are only minor changes in the reliability data presentation. To obtain a reasonable population for presenting reliability data for topside equipment in the 2015 edition, some data from phases VI and VII already issued in the previous 2009 handbook (5th edition) have also been included. The 2015 topside volume is divided into two parts. Part I describes the OREDA project, different data collection phases and the estimation procedures used to generate the data tables presented in Part II of the handbook. Topside data are in general not covering the whole lifetime of equipment, but ...

  13. The collection, storage and use of equipment performance data for the safety and reliability assessment of nuclear power plants

    International Nuclear Information System (INIS)

    Fothergill, C.D.H.

    1975-01-01

    It has been characteristic of the Nuclear Industry that it should grow up in an atmosphere where reliability and operational safety considerations have been of vital importance. Consequently all aspects of Nuclear Power Reactor design, construction and operation (in the U.K.A.E.A.) are subjected to rigorous reliability assessments, beginning with the automatic protective devices and the safety shut-down systems. This has resulted in the setting up of large and small private data stores to support this upsurgence of Safety and Reliability assessment work. Unfortunately, much of the information being stored and published falls short of the minimum requirements of Safety Assessors and Reliability Analysts who need to make use of it. That there is still an urgent need for more work to be done in the Reliability Data field is universally acknowledged. The characteristics which make up good quality reliability data must be defined and achievable minimum standards must be set for its identification, collection, storage and retrieval. To this end the United Kingdom Atomic Energy Authority have set up the Systems Reliability Service Data Bank. This includes a computerized storage facility comprised of two principal data stores: (i) Reliability Data Store, (ii) Event Data Store. The figures available in the Reliability Data Store range from those relating to the lifetimes of minute components to those obtained from the assessment of whole plants and complete assemblies. These data have been accumulated from many reliable sources both inside and outside the Nuclear Industry, including the transfer of 'live' data generated from the results of reliability surveillance exercises associated with Event Data collection. Computer techniques developed specifically for the Reliability Data Store enable further 'processing' of these data to be carried out. The Event Data Store consists of three discrete computerized data stores, each one providing the necessary storage, retrieval and

  14. Daya Bay Nuclear Power Station equipment reliability management system innovation

    International Nuclear Information System (INIS)

    Gao Ligang; Wang Zongjun

    2006-01-01

    Daya Bay Nuclear Power Station has achieved good performance since its commercial operation in 1994. The equipment reliability management system that features Daya Bay characteristics has been established through constant technology introduction, digestion and innovation. It is also based on the success of operational system, equipment maintenance system and technical support system. The system lays a solid foundation for the long-term safe operation of power station. This article emphasizes on the innovation part of equipment reliability management system in Daya Bay. (authors)

  15. An Evaluation Method of Equipment Reliability Configuration Management

    Science.gov (United States)

    Wang, Wei; Feng, Weijia; Zhang, Wei; Li, Yuan

    2018-01-01

    At present, many equipment development companies have been aware of the great significance of reliability of the equipment development. But, due to the lack of effective management evaluation method, it is very difficult for the equipment development company to manage its own reliability work. Evaluation method of equipment reliability configuration management is to determine the reliability management capabilities of equipment development company. Reliability is not only designed, but also managed to achieve. This paper evaluates the reliability management capabilities by reliability configuration capability maturity model(RCM-CMM) evaluation method.

  16. Research on the Reliability Testing of Electrical Automation Control Equipment

    OpenAIRE

    Yongjie Luo

    2014-01-01

    According to the author’s many years’ work experience, this paper first discusses the concepts of electrical automation control equipment reliability testing, and then analyzes the test method of electrical automation control equipment reliability testing, finally, on this basis, this article discusses how to determine the reliability test method of electrical automation control equipment. Results of this study will provide a useful reference for electrical automation control equipment reliab...

  17. Failure mode and effect analysis experimental reliability determination for the CANDU reactor equipment

    International Nuclear Information System (INIS)

    Vieru, G.

    1996-01-01

    This paper describes the experimental tests performed in order to prove the reliability parameters for certain equipment manufactured in INR Pitesti, for NPP Cernavoda. The tests were provided by Technical Specifications and test procedures. A comparison, referring to the reliability parameters, between Canadian equipment and INR manufactured equipment ones is also given. The results of tests and conclusions are shown. (author)

  18. FUNDAMENTALS OF RELIABILITY OF ELECTRIC POWER SYSTEM AND EQUIPMENT

    OpenAIRE

    Engr. Anumaka; Michael Chukwukadibia

    2011-01-01

    Today, the electric power system consists of complex interconnected network which are prone to different problems that militates against the reliability of the power system. Inadequate reliability in the power system causes problems such as high failure rate of power system installations and consumer equipment, transient and intransient faults, symmetrical faults etc. This paper provides an extensive review of the powers system and equipment reliability and related failure patterns in equipment.

  19. Equipment reliability process improvement and preventive maintenance optimization

    International Nuclear Information System (INIS)

    Darragi, M.; Georges, A.; Vaillancourt, R.; Komljenovic, D.; Croteau, M.

    2004-01-01

    The Gentilly-2 Nuclear Power Plant wants to optimize its preventive maintenance program through an Integrated Equipment Reliability Process. All equipment reliability related activities should be reviewed and optimized in a systematic approach especially for aging plants such as G2. This new approach has to be founded on best practices methods with the purpose of the rationalization of the preventive maintenance program and the performance monitoring of on-site systems, structures and components (SSC). A rational preventive maintenance strategy is based on optimized task scopes and frequencies depending on their applicability, critical effects on system safety and plant availability as well as cost-effectiveness. Preventive maintenance strategy efficiency is systematically monitored through degradation indicators. (author)

  20. Nuclear performance and reliability

    International Nuclear Information System (INIS)

    Rothwell, G.

    1993-01-01

    If fewer forced outages are a sign of improved safety, nuclear power plants have become safer and more productive. There has been a significant improvement in nuclear power plant performance, due largely to a decline in the forced outage rate and a dramatic drop in the average number of forced outages per fuel cycle. If fewer forced outages are a sign of improved safety, nuclear power plants have become safer and more productive over time. To encourage further increases in performance, regulatory incentive schemes should reward reactor operators for improved reliability and safety, as well as for improved performance

  1. Reliable design of electronic equipment an engineering guide

    CERN Document Server

    Natarajan, Dhanasekharan

    2014-01-01

    This book explains reliability techniques with examples from electronics design for the benefit of engineers. It presents the application of de-rating, FMEA, overstress analyses and reliability improvement tests for designing reliable electronic equipment. Adequate information is provided for designing computerized reliability database system to support the application of the techniques by designers. Pedantic terms and the associated mathematics of reliability engineering discipline are excluded for the benefit of comprehensiveness and practical applications. This book offers excellent support

  2. Reliability of nuclear power plants and equipment

    International Nuclear Information System (INIS)

    1985-01-01

    The standard sets the general principles, a list of reliability indexes and demands on their selection. Reliability indexes of nuclear power plants include the simple indexes of fail-safe operation, life and maintainability, and of storage capability. All terms and notions are explained and methods of evaluating the indexes briefly listed - statistical, and calculation experimental. The dates when the standard comes in force in the individual CMEA countries are given. (M.D.)

  3. Process plant equipment operation, control, and reliability

    CERN Document Server

    Holloway, Michael D; Onyewuenyi, Oliver A

    2012-01-01

    "Process Plant Equipment Book is another great publication from Wiley as a reference book for final year students as well as those who will work or are working in chemical production plants and refinery…" -Associate Prof. Dr. Ramli Mat, Deputy Dean (Academic), Faculty of Chemical Engineering, Universiti Teknologi Malaysia "…give[s] readers access to both fundamental information on process plant equipment and to practical ideas, best practices and experiences of highly successful engineers from around the world… The book is illustrated throughout with numerous black & white p

  4. Equipment reliability improvement process; implementation in Almaraz NPP and Trillo NPP

    International Nuclear Information System (INIS)

    Risquez Bailon, Aranzazu; Gutierrez Fernandez, Eduardo

    2010-01-01

    The Equipment Reliability Improvement Process (INPO AP-913) is a non-regulatory process developed by the US Nuclear Industry for improving Plants Availability. This Process integrates and coordinates a broad range of equipment reliability activities into one process, performed by the Plant in a non-centralized way. The integration and coordination of these activities will allow plant personnel to evaluate the trends of important station equipment, develop and implement long-term equipment health plans, monitor equipment performance and condition, and make adjustments to preventive maintenance tasks and frequencies based on equipment operating experience, if necessary, arbitrating operational and design improvements, to reach a Failure-free Operation. This paper describes the methodology of Equipment Reliability Improvement Process, being focused on main aspects of the implementation process, relating to the scope and establishment of an Equipment Reliability Monitoring Plan, which should include and complement the existing mechanisms and organizations in the Plant to monitor the condition and performance of the equipments, with the common aim of achieving an operation free of failures. The paper will describe the tools that Iberdrola Ingenieria has developed to support the implementation and monitoring of the Equipment Reliability Improvement Process, as well as the results and lessons learned from its implementation in Almaraz NPP and Trillo NPP. (authors)

  5. Reliability problems of heat transfer equipment

    International Nuclear Information System (INIS)

    Collier, J.G.

    1983-01-01

    A short historical account is given of the development of pressure vessel codes. The subject is then discussed under the headings: the cost of heat exchanger unreliability; degraded performance or failure; fouling; mal-distribution of flow; corrosion; erosion; vibration; thermal fatigue; corrosion fatigue; mal-operation; water hammer; conclusions. (U.K.)

  6. Problems in diagnosing and forecasting power equipment reliability

    Energy Technology Data Exchange (ETDEWEB)

    Popkov, V I; Demirchyan, K S

    1979-11-01

    This general survey deals with approaches to the resolution of such problems as the gathering, analysis and systematization of data on component defects in power equipment and setting up feedback with the manufacturing plants and planning organizations to improve equipment reliability. Such efforts on the part of designers, manufacturers and operating and repair organizations in analyzing faults in 300 MW turbogenerators during 1974-1977 reduced the specific fault rate by 20 to 25% and the downtime per failure by 35 to 40%. Since power equipment should operate for several hundreds of thousands of hours (20 to 30 years) and the majority of power components have guaranteed service lives of no more than 10/sup 5/ hours, an extremely difficult problem is the determination of the reliability of equipment past the 10/sup 5/ point. The present trend in the USSR Unified Power System towards increasing the number of shutdowns and startups, which in the case of turbogenerators of up 1200 MW power can reach 7500 to 10,000 cycles is noted. Other areas briefly treated are: MHD generator reliability and economy; nuclear power plant reliability and safety; the reliability of high-power high-voltage thyristor converters; the difficulties involved in scale modeling of power system reliability and the high cost of the requisite full-scale studies; the poor understanding of long term corrosion and erosion processes. The review concludes with arguments in favor of greater computerization of all aspects of power system management.

  7. Reliability and maintainability data acquisition in equipment development tests

    International Nuclear Information System (INIS)

    Haire, M.J.; Gift, E.H.

    1983-10-01

    The need for collection of reliability, maintainability, and availability data adds a new dimension to the data acquisition requirements of equipment development tests. This report describes the reliability and maintainability data that are considered necessary to ensure that sufficient and high quality data exist for a comprehensive, quantitative evaluation of equipment and system availability. These necessary data are presented as a set of data collection forms. Three data acquisition forms are discussed: an inventory and technical data form, which is filed by the design engineer when the design is finished or the equipment is received; an event report form, which is completed by the senior test operator at each shutdown; and a maintainability report, which is a collaborative effort between senior operators and lead engineers and is completed on restart. In addition, elements of a reliability, maintainability evaluation program are described. Emphasis is placed on the role of data, its storage, and use in such a program

  8. Purex: process and equipment performance

    International Nuclear Information System (INIS)

    Orth, D.A.

    1986-01-01

    The Purex process is the solvent extraction system that uses tributyl phosphate as the extractant for separating uranium and plutonium from irradiated reactor fuels. Since the first flowsheet was proposed at Oak Ridge National Laboratory in 1950, the process has endured for over 30 years with only minor modifications. The spread of the technology was rapid, and worldwide use or research on Purex-type processes was reported by the time of the 1955 Geneva Conference. The overall performance of the process has been so good that there are no serious contenders for replacing it soon. This paper presents: process description; equipment performance (mixer-settlers, pulse columns, rapid contactors); fission product decontamination; solvent effects (solvent degradation products); and partitioning of uranium and plutonium

  9. Improvement of Equipment reliability for Auxiliary Feed Water System

    Energy Technology Data Exchange (ETDEWEB)

    Deok, Lee Sang; Kwan, Lee Yong [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2013-10-15

    According to AP913 ER) of INPO, Number of the event related to equipment is higher than others like external or human performance. In the top 25 systems, Auxiliary feed water system is the seventh highest among systems. AWFS consists of many component and complex system and Main Function of AFWS is to supply feedwater to the steam generators for the removal of heat from the RCS(Reactor Coolant System) in event the main feedwater system is unavailable following a transient or accident. Reliability of component means how well operate on demands and monitoring is necessary to keep track of condition of component. If component performance is lower than the required value, corrective action for failure mode should be done. The objective of this study is focused to improve of AF pump by adding the tasks of SHR(System Health Report) into the task of system engineer walkdown of PMT(Preventive Maintenance Template). Increasing the reliability of AF pump will contribute to improvement of reliability of AFWS. Based on operating history, there was high vibration of AF pump during performance test. In that case, there were a lot of maintenance works for normal operation of AF pump. Vibration problem related pump can't be detected by tasks of SE walkdown because it's not running during normal operation except for surveillance test. CHR(Component Health Report) of AF pump in AFWS can be made from necessary part which means monitoring and functional failure because problem of Stand-by pump can be covered by conducting monitoring and analysis of functional failure. To improve reliability of AF pump, walkdown of PMT and SHR should be conducted both in accordance with surveillance test frequency. Health of AF pump based on operation history can be verified first and then can find out which parts of pump are weak. Finally, weak part can be managed intensively and failure can be reduced according to SE walkdown. But this work can be risky and burdensome because all parts of

  10. Photovoltaic performance and reliability workshop

    Energy Technology Data Exchange (ETDEWEB)

    Mrig, L. [ed.

    1993-12-01

    This workshop was the sixth in a series of workshops sponsored by NREL/DOE under the general subject of photovoltaic testing and reliability during the period 1986--1993. PV performance and PV reliability are at least as important as PV cost, if not more. In the US, PV manufacturers, DOE laboratories, electric utilities, and others are engaged in the photovoltaic reliability research and testing. This group of researchers and others interested in the field were brought together to exchange the technical knowledge and field experience as related to current information in this evolving field of PV reliability. The papers presented here reflect this effort since the last workshop held in September, 1992. The topics covered include: cell and module characterization, module and system testing, durability and reliability, system field experience, and standards and codes.

  11. Trends of HVDC technology - highly reliable converting equipment

    International Nuclear Information System (INIS)

    Muraoka, Yasuo; Kato, Yasushi; Watanabe, Atsumi; Kano, Takashi; Kawai, Tadao

    1983-01-01

    At present, the DC power transmission in Japan is practically used for the system connection of relatively small capacity, and the reliability of AC-DC converting system has been proven to exceed the world level by the operational results. However, when the application of this system to trunk power transmission of large capacity in future is considered, it is desirable to raise the reliability of converting equipment further and to develop the stabilized control techniques in harmony with connected AC system. Hitachi Ltd. has developed diversified system-related technologies centering around DC power transmission and the techniques for raising the reliability of converting equipment tending to large capacity. In this report, the results and the future prospect are described. The recent trend of DC power transmission, the development of DC power transmission technology such as the simulation analysis, the stable operation of a DC system connected to a weak AC system and the DC independent transmission from nuclear power stations, the technical development of light direct ignition thyristor bulbs and control protection equipment are reported. (Kako, I.)

  12. A study on the real-time reliability of on-board equipment of train control system

    Science.gov (United States)

    Zhang, Yong; Li, Shiwei

    2018-05-01

    Real-time reliability evaluation is conducive to establishing a condition based maintenance system for the purpose of guaranteeing continuous train operation. According to the inherent characteristics of the on-board equipment, the connotation of reliability evaluation of on-board equipment is defined and the evaluation index of real-time reliability is provided in this paper. From the perspective of methodology and practical application, the real-time reliability of the on-board equipment is discussed in detail, and the method of evaluating the realtime reliability of on-board equipment at component level based on Hidden Markov Model (HMM) is proposed. In this method the performance degradation data is used directly to realize the accurate perception of the hidden state transition process of on-board equipment, which can achieve a better description of the real-time reliability of the equipment.

  13. Equipment improvements for performance enhancement

    International Nuclear Information System (INIS)

    Gaestel, P.; Guesnon, H.; Sauze, G.

    1994-01-01

    In order to enhance the reactor availability, several improvements on reactor equipment have been developed: design optimization for stator maintenance replacement in the main alternator; adjustment modification of stator coils in the main alternator for an easier maintenance; improvement of the fuel handling line (pole crane, transfer equipment, loading machine); development of a loose part trapping system in the steam generator secondary circuit. 1 tab

  14. Domestic manufacturing and reliability improvement of reactor water recirculation equipment

    International Nuclear Information System (INIS)

    Kobayashi, Hidekazu; Oi, Masao; Shida, Toichi; Yokomori, Takashi

    1982-01-01

    The reactor coolant recirculation system is one of the important systems to control the reactor output in BWR nuclear power plants. Its components require high reliability and maintainability as well as controllability. For many Japanese nuclear power plants, recirculation pumps, fluid couplings and others have been imported so far. Hitachi Ltd. has established a domestic manufacturing organization through the development and test of these equipment. The fundamental design conditions for these equipment are the improvement of the rate of utilization of plant facility, the capability to follow load, and output power stability. In this paper, the specifications, the investigation of moment of inertia and the design features of recirculation pumps, driving motors and variable frequency power supply systems are described. The paper also reports on the combination test implemented to evaluate the recirculation system. The combination test includes the test using water rheostat for the power source facility and the loading test for a recirculation pump. The application of those system equipment to an actual plant was analyzed and evaluated on a basis of the test data obtained. The result showed that the equipment can achieve the rate of change of reactor power of 30%/min. Those equipment have been employed for No. 2 reactor plant of the Fukushima No. 2 Nuclear Power Station, the Tokyo Electric Power Co., Inc. (Wakatsuki, Y.)

  15. Characteristics and application study of AP1000 NPPs equipment reliability classification method

    International Nuclear Information System (INIS)

    Guan Gao

    2013-01-01

    AP1000 nuclear power plant applies an integrated approach to establish equipment reliability classification, which includes probabilistic risk assessment technique, maintenance rule administrative, power production reliability classification and functional equipment group bounding method, and eventually classify equipment reliability into 4 levels. This classification process and result are very different from classical RCM and streamlined RCM. It studied the characteristic of AP1000 equipment reliability classification approach, considered that equipment reliability classification should effectively support maintenance strategy development and work process control, recommended to use a combined RCM method to establish the future equipment reliability program of AP1000 nuclear power plants. (authors)

  16. Developing Predictive Maintenance Expertise to Improve Plant Equipment Reliability

    International Nuclear Information System (INIS)

    Wurzbach, Richard N.

    2002-01-01

    On-line equipment condition monitoring is a critical component of the world-class production and safety histories of many successful nuclear plant operators. From addressing availability and operability concerns of nuclear safety-related equipment to increasing profitability through support system reliability and reduced maintenance costs, Predictive Maintenance programs have increasingly become a vital contribution to the maintenance and operation decisions of nuclear facilities. In recent years, significant advancements have been made in the quality and portability of many of the instruments being used, and software improvements have been made as well. However, the single most influential component of the success of these programs is the impact of a trained and experienced team of personnel putting this technology to work. Changes in the nature of the power generation industry brought on by competition, mergers, and acquisitions, has taken the historically stable personnel environment of power generation and created a very dynamic situation. As a result, many facilities have seen a significant turnover in personnel in key positions, including predictive maintenance personnel. It has become the challenge for many nuclear operators to maintain the consistent contribution of quality data and information from predictive maintenance that has become important in the overall equipment decision process. These challenges can be met through the implementation of quality training to predictive maintenance personnel and regular updating and re-certification of key technology holders. The use of data management tools and services aid in the sharing of information across sites within an operating company, and with experts who can contribute value-added data management and analysis. The overall effectiveness of predictive maintenance programs can be improved through the incorporation of newly developed comprehensive technology training courses. These courses address the use of

  17. Equipment design for reliability testing of protection system

    International Nuclear Information System (INIS)

    Situmorang, Johnny; Tjahjono, H.; Santosa, A. Z.; Tjahjani, S.DT.; Ismu, P.H; Haryanto, D.; Mulyanto, D.; Kusmono, S

    1999-01-01

    The equipment for reliability testing of cable of protection system has been designed as a a furnace with the electric heater have a 4 kW power, and need time 10 minute to reach the designed maximum temperature 3000C. The dimension of furnace is 800 mm diameter and 2000 mm length is isolated use rockwool isolator and coated by aluminium. For the designed maximum temperature the surface temperature is 78 0c. Assemble of specimens is arranged horizontally in the furnace. The failure criteria will be defined based on the behaviour of the load circuit in each line of cable specimens

  18. Considerations concerning the reliability of reactor safety equipment

    International Nuclear Information System (INIS)

    Furet, J.; Guyot, Ch.

    1967-01-01

    A review is made of the circumstances which favor a good collection of maintenance data at the C.E.A. The large amount of data to be treated has made necessary the use of a computer for analyzing automatically the results collected. Here, only particular aspects of the reliability from the point of view of the electronics used for nuclear reactor control will be dealt with: sale and unsafe failures; probability of survival (in the case of reactor safety); availability. The general diagrams of the safety assemblies which have been drawn up for two types of reactor (power reactor and low power experimental reactor) are given. Results are presented of reliability analysis which could be applied to the use of functional modular elements, developed industrially in France. Improvement of this reliability appears to be fairly limited by an increase in the redundancy; on the other hand it is shown how it may be very markedly improved by the use of automatic tests with different frequencies for detecting unsafe failures rates of measurements for the sub-assemblies and for the logic sub-assemblies. Finally examples are given to show the incidence of the complexity and of the use of different technologies in reactor safety equipment on the reliability. (authors) [fr

  19. Safety systems I/C equipment reliability analyses of the Kozloduy NPP units 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Halev, G; Christov, N [Risk Engineering Ltd., Sofia (Bulgaria)

    1996-12-31

    The purpose of the analysis is to assess the safety systems I/C equipment reliability. The assessment includes: quantification of the safety systems unavailability due to component failures; definition of the minimal cut sets leading to the analysed safety systems failure; quantification of the I/C equipment importance measures of the dominant contribution components. The safety systems I/C equipment reliability has been analysed using PSAPACK (a code for probabilistic safety assessment). Fault trees for the following safety systems of the Kozloduy-3 and Kozloduy-4 reactors have been constructed: neutron flow control equipment, reactor protection system, main coolant pumps, pressurizer safety valves `Sempell`, steam dump systems, spray system, low pressure injection system, emergency feeding water system, essential service water system. THree separate reports have been issued containing the performed analyses and results. 1 ref.

  20. The establish and application of equipment reliability database in Nuclear Power Plant

    International Nuclear Information System (INIS)

    Zheng Wei; Li He

    2006-03-01

    Take the case of Daya Bay Nuclear Power Plant, the collecting and handling of equipment reliability data, the calculation method of reliability parameters and the establish and application of reliability databases, etc. are discussed. The data source involved the design information of the equipment, the operation information, the maintenance information and periodically test record, etc. Equipment reliability database built on a base of the operation experience. It provided the valid tool for thoroughly and objectively recording the operation history and the present condition of various equipment of the plant; supervising the appearance of the equipment, especially the safety-related equipment, provided the very practical worth information for enhancing the safety and availability management of the equipment and insuring the safety and economic operation of the plant; and provided the essential data for the research and applications in safety management, reliability analysis, probabilistic safety assessment, reliability centered maintenance and economic management in nuclear power plant. (authors)

  1. Study on the Management for the Nuclear Power Plant Maintenance and Equipment Reliability

    International Nuclear Information System (INIS)

    Yoon, Kyeongseop; Lee, Sangheon; Kim, Myungjin; Lee, Unjang

    2015-01-01

    In our country, many studies on the regulatory policy of the plant maintenance have ever been performed since 1998, but the relevant regulatory requirements were not established yet. These background mentioned above request us to study on the regulation policy and maintenance plan to improve the safety, reliability and efficiency of NPP. To solve these problems, in this study, we deduct the management methodology for the improvement of NPP maintenance and equipment reliability that is essential to secure the safety and efficiency of the commercial NPP. For analysis the maintenance and equipment reliability management methodology in overseas NPP. We studied maintenance and equipment reliability of USA, Canada and Europe(France, England, German). We also studied status and application condition of Korean NPP maintenance management technical development. We deducted an effective maintenance methodology that is needed to Korean NPP, as a result of comparison on the technical trend of the maintenance management between overseas and Korean, such like following. - Regulation form ·Specific provision of regulation requirement and application of form that is clarifying application standard - Maintenance management methodology, Maintenance management program. This results of study could be applied for regulation policy, law and guideline establishment of NPP maintenance, operation, supervision and a system establishment for maintenance management, education data about maintenance for NPP employees

  2. About water chemistry influence on equipment reliability of NPP with RBMK-1000

    International Nuclear Information System (INIS)

    Berezina, I.G.; Styazhkin, P.S.; Kritskij, V.G.

    2001-01-01

    In the paper the experience of a quantitative valuation of coolant quality influence on a reliability of some equipment elements of NPP with RBMK-1000 is offered. The choice is made of coolant quality integral parameter. The connection between indices values of coolant quality and reliability of major elements of circulation circuit equipment (including fuel claddings) is established. The reliability improvement of equipment elements operation is supported by high water chemistry quality. (orig.)

  3. Equipment size effects on open pit mining performance

    Energy Technology Data Exchange (ETDEWEB)

    A. Bozorgebrahimi; R.A. Hall; M.A. Morin [University of British Columbia, Vancouver, BC (Canada). Mining Engineering Department

    2005-03-01

    This paper discusses the exploitation of economies of scale in open pit mining through the use of increasingly larger equipment. It presents a method adopted to evaluate the impact of increased scale on operational performance factors. The work identifies equipment size sensitive variables (ESSVs) in the mine design process that affect the performance of the production process. Data from a set of case studies show that the ESSV influence extends beyond mine production to encompass milling performance, environmental footprint and community impacts. Some ESSVs (such as reliability, tyre costs and productivity) are shown to be related to the current state of equipment technology and their effects are therefore comparable for different mines. Other ESSVs relate to the mine and deposit characteristics; their effects therefore vary from mine to mine. A detailed analytical approach, developed to model the impact of ESSVs, suggests that for truck/shovel operations, the industry may be approaching a situation of diseconomies of scale.

  4. Enhancing reliability of ultrasonic testing of welds of nuclear power plant equipment

    International Nuclear Information System (INIS)

    Shcherbinskij, V.G.

    1981-01-01

    Results of investigation of factors influencing the reliability of manual ultrasonic testing of welded joints and weld deposited metal power-generating equipment are presented. Recommendations on the enhancing of reliability are given [ru

  5. Maintenance and test strategies to optimize NPP equipment performance

    International Nuclear Information System (INIS)

    Mayer, S.; Tomic, B.

    2000-01-01

    This paper proposes an approach to maintenance optimization of nuclear power plant components, which can help to increase both safety and availability. In order to evaluate the benefits of preventive maintenance on a quantitative basis, a software code has been developed for component performance and reliability simulation of safety related nuclear power plant equipment. A three state Markov model will be introduced, considering a degraded state in addition to an operational state and a failed state. (author)

  6. System Reliability Analysis Considering Correlation of Performances

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Saekyeol; Lee, Tae Hee [Hanyang Univ., Seoul (Korea, Republic of); Lim, Woochul [Mando Corporation, Seongnam (Korea, Republic of)

    2017-04-15

    Reliability analysis of a mechanical system has been developed in order to consider the uncertainties in the product design that may occur from the tolerance of design variables, uncertainties of noise, environmental factors, and material properties. In most of the previous studies, the reliability was calculated independently for each performance of the system. However, the conventional methods cannot consider the correlation between the performances of the system that may lead to a difference between the reliability of the entire system and the reliability of the individual performance. In this paper, the joint probability density function (PDF) of the performances is modeled using a copula which takes into account the correlation between performances of the system. The system reliability is proposed as the integral of joint PDF of performances and is compared with the individual reliability of each performance by mathematical examples and two-bar truss example.

  7. System Reliability Analysis Considering Correlation of Performances

    International Nuclear Information System (INIS)

    Kim, Saekyeol; Lee, Tae Hee; Lim, Woochul

    2017-01-01

    Reliability analysis of a mechanical system has been developed in order to consider the uncertainties in the product design that may occur from the tolerance of design variables, uncertainties of noise, environmental factors, and material properties. In most of the previous studies, the reliability was calculated independently for each performance of the system. However, the conventional methods cannot consider the correlation between the performances of the system that may lead to a difference between the reliability of the entire system and the reliability of the individual performance. In this paper, the joint probability density function (PDF) of the performances is modeled using a copula which takes into account the correlation between performances of the system. The system reliability is proposed as the integral of joint PDF of performances and is compared with the individual reliability of each performance by mathematical examples and two-bar truss example.

  8. Developing a system engineering program to improve performance and reliability

    International Nuclear Information System (INIS)

    Keuter, D.

    1985-01-01

    After several maintenance, operational, and equipment problems last year, Trojan set out on a mission to improve plant performance and reliability by strengthening its on-site engineering organization. This paper presents Trojan's plans in developing an on-site system engineering organization

  9. Reliability data of fire protection equipment and features in German nuclear power plants

    International Nuclear Information System (INIS)

    Roewekamp, M.; Riekert, T.; Sehrbrock, W.

    1997-01-01

    In order to perform probabilistic fire safety analyses, a comprehensive data base is needed including physical characteristics of fire compartments and their inventory, fire occurrence frequencies, technical reliability data for all fire-related equipment, human actions and human error probabilities, etc. In order to provide updated and realistic reliability data, the operational behaviour of different fire protection features in two German nuclear power plants was analysed in the framework of the study presented here. The analyses are based on the examination of reported results of the regular inspection and maintenance programs for nuclear power plants. Besides a plant specific assessment of the reliability data a generic assessment for an application as input data for fault tree analyses in the framework of probabilistic risk studies for other German plants was carried out. The analyses of failures and unavailabilities gave the impression that most of them are single failures without relevance for the plant safety. The data gained from NPPs were compared to reliability data of the German insurance companies for the same protection features installed in non-nuclear installations and to older nuclear specific reliability data. This comparison showed up a higher reliability. (orig.) [de

  10. A comparative study on the HW reliability assessment methods for digital I and C equipment

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hoan Sung; Sung, T. Y.; Eom, H. S.; Park, J. K.; Kang, H. G.; Lee, G. Y. [Korea Atomic Energy Research Institute, Taejeon (Korea); Kim, M. C. [Korea Advanced Institute of Science and Technology, Taejeon (Korea); Jun, S. T. [KHNP, Taejeon (Korea)

    2002-03-01

    It is necessary to predict or to evaluate the reliability of electronic equipment for the probabilistic safety analysis of digital instrument and control equipment. But most databases for the reliability prediction have no data for the up-to-date equipment and the failure modes are not classified. The prediction results for the specific component show different values according to the methods and databases. For boards and systems each method shows different values than others also. This study is for reliability prediction of PDC system for Wolsong NPP1 as a digital I and C equipment. Various reliability prediction methods and failure databases are used in calculation of the reliability to compare the effects of sensitivity and accuracy of each model and database. Many considerations for the reliability assessment of digital systems are derived with the results of this study. 14 refs., 19 figs., 15 tabs. (Author)

  11. Implementation of the project of equipment reliability in the nuclear power plant of Laguna Verde

    International Nuclear Information System (INIS)

    Rios O, J. E.; Martinez L, A. G.

    2008-01-01

    A equipment is reliable if it fulfills the function for which was designed and when it is required. To implement a project of reliability in a nuclear power plant this associate to a process of continuous analysis of the operation, of the conditions and faults of the equipment. The analysis of the operation of a system, of the equipment of the same faults and the parts that integrate to equipment take to identify the potential causes of faults. The predictive analysis on components and equipment allow to rectify and to establish guides to optimize the maintenance and to guarantee the reliability and function of the same ones. The reliability in the equipment is without place to doubts a wide project that embraces from the more small component of the equipment going by the proof of the parts of reserve, the operation conditions until the operative techniques of analysis. Without place of doubt for a nuclear power plant the taking of decisions based on the reliability of their systems and equipment will be the appropriate for to assure the operation and reliability of the same one. In this work would appear the project of reliability its processes, criteria, indicators action of improvement and the interaction of the different disciplines from the Nuclear Power Plant of Laguna Verde like a fundamental point for it put in operation. (Author)

  12. Tracking reliability for space cabin-borne equipment in development by Crow model.

    Science.gov (United States)

    Chen, J D; Jiao, S J; Sun, H L

    2001-12-01

    Objective. To study and track the reliability growth of manned spaceflight cabin-borne equipment in the course of its development. Method. A new technique of reliability growth estimation and prediction, which is composed of the Crow model and test data conversion (TDC) method was used. Result. The estimation and prediction value of the reliability growth conformed to its expectations. Conclusion. The method could dynamically estimate and predict the reliability of the equipment by making full use of various test information in the course of its development. It offered not only a possibility of tracking the equipment reliability growth, but also the reference for quality control in manned spaceflight cabin-borne equipment design and development process.

  13. Mobility and reliability performance measurement.

    Science.gov (United States)

    2013-06-01

    This project grew out of the fact that mobility was identified early on as one of the key performance focus areas of NCDOTs : strategic transformation effort. The Transformation Management Team (TMT) established a TMT Mobility Workstream Team : in...

  14. Seismic proving tests on the reliability for large components and equipment of nuclear power plants

    International Nuclear Information System (INIS)

    Ohno, Tokue; Tanaka, Nagatoshi

    1988-01-01

    Since Japan has destructive earthquakes frequently, the structural reliability for large components and equipment of nuclear power plants are rigorously required. They are designed using sophisticated seismic analyses and have not yet encountered a destructive earthquake. When nuclear power plants are planned, it is very important that the general public understand the structural reliability during and after an earthquake. Seismic Proving Tests have been planned by Ministry of International Trade and Industry (Miti) to comply with public requirement in Japan. A large-scale high-performance vibration table was constructed at Tasted Engineering Laboratory of Nuclear Power Engineering Test Center (NU PEC), in order to prove the structural reliability by vibrating the test model (of full scale or close to the actual size) in the condition of a destructive earthquake. As for the test models, the following four items were selected out of large components and equipment important to the safety: Reactor Containment Vessel; Primary Coolant Loop or Primary Loop Recirculation System; Reactor Pressure Vessel; and Reactor Core Internals. Here is described a brief of the vibration table, the test method and the results of the tests on PWR Reactor Containment Vessel and BWR Primary Loop Recirculation System (author)

  15. Compilation of the calculation elements of the electronic equipments reliability

    International Nuclear Information System (INIS)

    Lefevre, R.; D'Harcourt, A.; Dupuy, G.

    1968-01-01

    The aim of this work is to allow the practical execution of the estimated calculation of the electronic devices reliability and to standardize the source and the approach of the calculations while giving a systematic character to their execution mode. The systematic character of the calculations allows a comparison of the reliability of different materials and a rapid control of the calculations validity; at last, it brings out the use conditions of all the components of a set. A reliability calculation made according to the method described here reveals: -components badly used -the relative influence on the reliability of the set, of a component or a components group taking into account of the number, of the characteristics and of the use of these ones. At last, the results of the calculation allows to organize the exploitation (availability) and the maintenance (staff, stock of components) of the materials. The failure rates given in this book are only relating to the components service-life and do not correspond to precocious failures. (authors) [fr

  16. A New Method of Reliability Evaluation Based on Wavelet Information Entropy for Equipment Condition Identification

    International Nuclear Information System (INIS)

    He, Z J; Zhang, X L; Chen, X F

    2012-01-01

    Aiming at reliability evaluation of condition identification of mechanical equipment, it is necessary to analyze condition monitoring information. A new method of reliability evaluation based on wavelet information entropy extracted from vibration signals of mechanical equipment is proposed. The method is quite different from traditional reliability evaluation models that are dependent on probability statistics analysis of large number sample data. The vibration signals of mechanical equipment were analyzed by means of second generation wavelet package (SGWP). We take relative energy in each frequency band of decomposed signal that equals a percentage of the whole signal energy as probability. Normalized information entropy (IE) is obtained based on the relative energy to describe uncertainty of a system instead of probability. The reliability degree is transformed by the normalized wavelet information entropy. A successful application has been achieved to evaluate the assembled quality reliability for a kind of dismountable disk-drum aero-engine. The reliability degree indicates the assembled quality satisfactorily.

  17. Delivering on Industry Equipment Reliability Goals By Leveraging an Integration Platform and Decision Support Environment

    International Nuclear Information System (INIS)

    Coveney, Maureen K.; Bailey, W. Henry; Parkinson, William

    2004-01-01

    Utilities have invested in many costly enterprise systems - computerized maintenance management systems, document management systems, enterprise grade portals, to name but a few - and often very specialized systems, like data historians, high end diagnostic systems, and other focused and point solutions. From recent industry reports, we now know that the average nuclear power utilizes on average 1900 systems to perform daily work, of which 250 might facilitate the equipment reliability decision-making process. The time has come to leverage the investment in these systems by providing a common platform for integration and decision-making that will further the collective industry aim of enhancing the reliability of our nuclear generation assets to maintain high plant availability and to deliver on plant life extension goals without requiring additional large scale investment in IT infrastructure. (authors)

  18. Technology and equipment to improve reliability of pipeline transport

    Science.gov (United States)

    Suleimanov, D. F.; Shulayev, N. S.; Bondar, K. E.; Laponov, S. V.; Uzinger, A. A.

    2017-10-01

    The article is dedicated to development of technology and hardware design of method pipeline transport reliability improving by improving the isolated coating properties modified by microwave radiation. The article describes the technology of the modification process of the coating and instrumentation production, which allows improving operational properties not only in stationary conditions in the manufacture of the insulation coating, but also during its replacement in the field.

  19. Reliability analysis of mining equipment: A case study of a crushing plant at Jajarm Bauxite Mine in Iran

    International Nuclear Information System (INIS)

    Barabady, Javad; Kumar, Uday

    2008-01-01

    The performance of mining machines depends on the reliability of the equipment used, the operating environment, the maintenance efficiency, the operation process, the technical expertise of the miners, etc. As the size and complexity of mining equipments continue to increase, the implications of equipment failure become ever more critical. Therefore, reliability analysis is required to identify the bottlenecks in the system and to find the components or subsystems with low reliability for a given designed performance. It is important to select a suitable method for data collection as well as for reliability analysis. This paper presents a case study describing reliability and availability analysis of the crushing plant number 3 at Jajarm Bauxite Mine in Iran. In this study, the crushing plant number 3 is divided into six subsystems. The parameters of some probability distributions, such as Weibull, Exponential, and Lognormal distributions have been estimated by using ReliaSoft's Weibull++6 software. The results of the analysis show that the conveyer subsystem and secondary screen subsystem are critical from a reliability point of view, and the secondary crusher subsystem and conveyer subsystem are critical from an availability point of view. The study also shows that the reliability analysis is very useful for deciding maintenance intervals

  20. Internet Performance and Reliability Measurements

    International Nuclear Information System (INIS)

    Cottrell, Les

    2003-01-01

    Collaborative HEP research is dependent on good Internet connectivity. Although most local- and wide-area networks are carefully watched, there is little monitoring of connections that cross many networks. This paper describes work in progress at several sites to monitor Internet end-to-end performance between hundreds of HEP sites worldwide. At each collection site, ICMP ping packets are automatically sent periodically to sites of interest. The data is recorded and made available to analysis nodes, which collect the data from multiple collection sites and provide analysis and graphing. Future work includes improving the efficiency and accuracy of ping data collection

  1. Efficiency evaluation of an electronic equipment: availability,reliability and maintenance

    International Nuclear Information System (INIS)

    Guyot, C.

    1966-01-01

    This concept of efficiency often called ''system effectiveness'', is presented and analyzed in terms of reliability and maintenance. It allows to define the availability factor of an electronic equipment. A procedure of evaluation is proposed. (A.L.B.)

  2. [A reliability growth assessment method and its application in the development of equipment in space cabin].

    Science.gov (United States)

    Chen, J D; Sun, H L

    1999-04-01

    Objective. To assess and predict reliability of an equipment dynamically by making full use of various test informations in the development of products. Method. A new reliability growth assessment method based on army material system analysis activity (AMSAA) model was developed. The method is composed of the AMSAA model and test data conversion technology. Result. The assessment and prediction results of a space-borne equipment conform to its expectations. Conclusion. It is suggested that this method should be further researched and popularized.

  3. System design and equipment reliability for wide web working at Hem Heath Colliery

    Energy Technology Data Exchange (ETDEWEB)

    Hall, L

    1982-02-01

    This paper outlines the challenge to mining engineers on system design and reliability of equipment and how Hem Heath Colliery in the UK, is meeting this challenge, by describing current systems of work and equipment on the faces, summarising experience gained with succeeding faces, the results achieved, and posing considerations for the future.

  4. Study on highly reliable digital communication technology of reactor nuclear measuring equipment

    International Nuclear Information System (INIS)

    Gu Pengfei; Huang Xiaojin

    2007-01-01

    To meet the need of highly reliable of reactor nuclear measuring equipment, in allusion to the idiographic request of nuclear measuring equipment, the actual technical development and the application in industrial field, we design a kind of redundancy communication net based on PROFIBUS, and a kind of communication interface module based on redundancy PROFIBUS communication, which link the nuclear measuring equipment and PROFIBUS communication net, and also lay a foundation for advanced research. (authors)

  5. MHTGR thermal performance envelopes: Reliability by design

    International Nuclear Information System (INIS)

    Etzel, K.T.; Howard, W.W.; Zgliczynski, J.B.

    1992-05-01

    This document discusses thermal performance envelopes which are used to specify steady-state design requirements for the systems of the Modular High Temperature Gas-Cooled Reactor to maximize plant performance reliability with optimized design. The thermal performance envelopes are constructed around the expected operating point accounting for uncertainties in actual plant as-built parameters and plant operation. The components are then designed to perform successfully at all points within the envelope. As a result, plant reliability is maximized by accounting for component thermal performance variation in the design. The design is optimized by providing a means to determine required margins in a disciplined and visible fashion

  6. Dental CBCT equipment and performance issues

    International Nuclear Information System (INIS)

    Horner, K.; Jacobs, R.; Schulze, R.

    2013-01-01

    Dental cone beam computed tomography (CBCT), also known as digital volumetric tomography was developed in the late 1990s and is now increasingly available in clinical practice. It can provide high resolution cross-sectional images of teeth and the maxillofacial region with applications in all branches of dentistry. As a new imaging modality, there were no established suspension levels at a European level. A literature review, encompassing scientific, professional publications and existing national guidelines was performed in an attempt to develop a set of suspension levels for dental CBCT, using additional expert opinion from the members of the European Academy of dento-maxillo-facial radiology. A limited set of suspension levels has been devised for aspects of the X-ray tube and generator, dosimetry, field-of-view, alignment and image quality. These should be kept under review in the light of growing experience of testing equipment in practice. (authors)

  7. Delivering high performance BWR fuel reliably

    International Nuclear Information System (INIS)

    Schardt, J.F.

    1998-01-01

    Utilities are under intense pressure to reduce their production costs in order to compete in the increasingly deregulated marketplace. They need fuel, which can deliver high performance to meet demanding operating strategies. GE's latest BWR fuel design, GE14, provides that high performance capability. GE's product introduction process assures that this performance will be delivered reliably, with little risk to the utility. (author)

  8. MEASUREMENT: ACCOUNTING FOR RELIABILITY IN PERFORMANCE ESTIMATES.

    Science.gov (United States)

    Waterman, Brian; Sutter, Robert; Burroughs, Thomas; Dunagan, W Claiborne

    2014-01-01

    When evaluating physician performance measures, physician leaders are faced with the quandary of determining whether departures from expected physician performance measurements represent a true signal or random error. This uncertainty impedes the physician leader's ability and confidence to take appropriate performance improvement actions based on physician performance measurements. Incorporating reliability adjustment into physician performance measurement is a valuable way of reducing the impact of random error in the measurements, such as those caused by small sample sizes. Consequently, the physician executive has more confidence that the results represent true performance and is positioned to make better physician performance improvement decisions. Applying reliability adjustment to physician-level performance data is relatively new. As others have noted previously, it's important to keep in mind that reliability adjustment adds significant complexity to the production, interpretation and utilization of results. Furthermore, the methods explored in this case study only scratch the surface of the range of available Bayesian methods that can be used for reliability adjustment; further study is needed to test and compare these methods in practice and to examine important extensions for handling specialty-specific concerns (e.g., average case volumes, which have been shown to be important in cardiac surgery outcomes). Moreover, it's important to note that the provider group average as a basis for shrinkage is one of several possible choices that could be employed in practice and deserves further exploration in future research. With these caveats, our results demonstrate that incorporating reliability adjustment into physician performance measurements is feasible and can notably reduce the incidence of "real" signals relative to what one would expect to see using more traditional approaches. A physician leader who is interested in catalyzing performance improvement

  9. Providing reliable equipment to IAEA through a low risk transition plan

    International Nuclear Information System (INIS)

    Green, L.; Weinstock, E.V.; Karlin, E.W.

    1988-01-01

    The development and production of safeguards equipment is a complex process containing many potential pitfalls between the conceptual design and its implementation in the field. The conditions for equipment use are especially demanding. At the same time, the consequences of failure may be serious. Repeated failure may result in the loss of credibility of safeguards. Expensive back up measures such as re-verification of inventories may be required. Inspectors may come to distrust the equipment. Finally, the expense of maintaining the equipment may be excessive. It is therefore essential that the process for bringing equipment for the conceptual stage to actual routine use minimizes the risk of producing equipment that is unsuitable for the job. Fortunately, approaches for accomplishing this have already been developed in both the industrial and commercial sectors. One such approach, the Low Risk Transition Plan (LRTP) is described to show it can be applied to the production of reliable safeguards equipment

  10. Performance characterization of night vision equipment based on Triangle Orientation Discrimination (TOD) methodology

    NARCIS (Netherlands)

    Laurent, N.; Lejard, C.; Deltel, G.; Bijl, P.

    2013-01-01

    Night vision equipment is crucial in order to accomplish supremacy and safety of the troops on the battlefield. Evidently, system integrators, MODs and end-users need access to reliable quantitative characterization of the expected field performance when using night vision equipment. The Image

  11. Equipment performance monitoring in NPP Krsko (Summarized system health report)

    International Nuclear Information System (INIS)

    Djetelic, N.; Cicvaric, D.

    2004-01-01

    Management common goal is safe, reliable, effective, acceptable to public and conservative/cautious operation of NPP Krsko. A set of programs, including Corrective Action Program, Performance Indicators, Operating Experience, Self Assessment and System Health Report, is developed to assist NPP Krsko management in fulfilling those goals. System Health Report is a tool that management can use to quickly assess how selected systems are performing, to determine where additional management attention is required and to determine if appropriate corrective actions have been established. Summarized System Health Report is developed for management's quick overview of systems status, important system malfunctions and problems as well as major changes from previous assessment period. Summarized Report contains nine sections: status difference including brief explanation, selected performance indicators, new equipment problems, functional failures, important problem analyses, action plan for systems with Potential Danger (RED) status, maintenance rule status overview and systems availability (planned and unplanned).(author)

  12. On the reliability evaluation of communication equipment for SMART using FMEA

    International Nuclear Information System (INIS)

    Kim, D. H.; Suh, Y. S.; Koo, I. S.; Song, Ki Sang; Han, Byung Rae

    2000-07-01

    This report describes the reliability analysis method for communication equipment using FMEA and FTA. The major equipments to be applicable for SMART communication networks are repeater, bridge, router and gateway and we can apply the FMEA or FTA technique. In the FMEA process, analysis of tagged system, decision of the level of analysis of the target system, drawing reliability block diagram according to the function, decision of failure mode, writing the fault reasons, writing on the FMEA sheet and FMEA level decision are included. Also, the FTA, it is possible to figure out top event reasons and system reliability. We have considered these in mind and we did the FMEA and FTA for NIC, hub, client server and router. Also, we suggested and integrated network model for nuclear power plant and we have shown the reliability analysis procedure according to FTA. If any proprietary communication device is developed, the reliability can be easily determined with proposed procedures

  13. On the reliability evaluation of communication equipment for SMART using FMEA

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. H.; Suh, Y. S.; Koo, I. S.; Song, Ki Sang; Han, Byung Rae

    2000-07-01

    This report describes the reliability analysis method for communication equipment using FMEA and FTA. The major equipments to be applicable for SMART communication networks are repeater, bridge, router and gateway and we can apply the FMEA or FTA technique. In the FMEA process, analysis of tagged system, decision of the level of analysis of the target system, drawing reliability block diagram according to the function, decision of failure mode, writing the fault reasons, writing on the FMEA sheet and FMEA level decision are included. Also, the FTA, it is possible to figure out top event reasons and system reliability. We have considered these in mind and we did the FMEA and FTA for NIC, hub, client server and router. Also, we suggested and integrated network model for nuclear power plant and we have shown the reliability analysis procedure according to FTA. If any proprietary communication device is developed, the reliability can be easily determined with proposed procedures.

  14. On reliability and maintenance modelling of ageing equipment in electric power systems

    International Nuclear Information System (INIS)

    Lindquist, Tommie

    2008-04-01

    Maintenance optimisation is essential to achieve cost-efficiency, availability and reliability of supply in electric power systems. The process of maintenance optimisation requires information about the costs of preventive and corrective maintenance, as well as the costs of failures borne by both electricity suppliers and customers. To calculate expected costs, information is needed about equipment reliability characteristics and the way in which maintenance affects equipment reliability. The aim of this Ph.D. work has been to develop equipment reliability models taking the effect of maintenance into account. The research has focussed on the interrelated areas of condition estimation, reliability modelling and maintenance modelling, which have been investigated in a number of case studies. In the area of condition estimation two methods to quantitatively estimate the condition of disconnector contacts have been developed, which utilise results from infrared thermography inspections and contact resistance measurements. The accuracy of these methods were investigated in two case studies. Reliability models have been developed and implemented for SF6 circuit-breakers, disconnector contacts and XLPE cables in three separate case studies. These models were formulated using both empirical and physical modelling approaches. To improve confidence in such models a Bayesian statistical method incorporating information from the equipment design process was also developed. This method was illustrated in a case study of SF6 circuit-breaker operating rods. Methods for quantifying the effect of maintenance on equipment condition and reliability have been investigated in case studies on disconnector contacts and SF6 circuit-breakers. The input required by these methods are condition measurements and historical failure and maintenance data, respectively. This research has demonstrated that the effect of maintenance on power system equipment may be quantified using available data

  15. A Study on Performance and Safety Tests of Defibrillator Equipment

    Directory of Open Access Journals (Sweden)

    Tavakoli Golpaygani A.

    2017-12-01

    Full Text Available Introduction: Nowadays, more than 10,000 different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the required level of performance. Defibrillators are critical resuscitation devices. The use of reliable defibirillators has led to more effective treatments and improved patient safety through better control and management of complications during Cardiopulmonary Resuscitation (CPR. Materials and Methods: The metrological reliability of twenty frequent use, manual defibrillators in use ten hospitals (4 private and 6 public in one of the provinces of Iran according to international and national standards was evaluated. Results: Quantitative analysis of control and instrument accuracy showed the amount of the obtained results in many units are critical which had less value over the standard limitations especially in devices with poor battery. For the accuracy of delivered energy analysis, only twelve units delivered acceptable output values and the precision in the output energy measurements especialy in weak battry condition, after activation of discharge alarm, were low. Conclusion: Obtained results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially for high risk instruments. It is also necessary to provide training courses on the fundumentals of operation and performane parameters for medical staff in the field of meterology in medicine and how one can get good accuracy results especially in high risk medical devices.

  16. A Study on Performance and Safety Tests of Defibrillator Equipment.

    Science.gov (United States)

    Tavakoli Golpaygani, A; Movahedi, M M; Reza, M

    2017-12-01

    Nowadays, more than 10,000 different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the required level of performance. Defibrillators are critical resuscitation devices. The use of reliable defibirillators has led to more effective treatments and improved patient safety through better control and management of complications during Cardiopulmonary Resuscitation (CPR). The metrological reliability of twenty frequent use, manual defibrillators in use ten hospitals (4 private and 6 public) in one of the provinces of Iran according to international and national standards was evaluated. Quantitative analysis of control and instrument accuracy showed the amount of the obtained results in many units are critical which had less value over the standard limitations especially in devices with poor battery. For the accuracy of delivered energy analysis, only twelve units delivered acceptable output values and the precision in the output energy measurements especialy in weak battry condition, after activation of discharge alarm, were low. Obtained results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially for high risk instruments. It is also necessary to provide training courses on the fundumentals of operation and performane parameters for medical staff in the field of meterology in medicine and how one can get good accuracy results especially in high risk medical devices.

  17. Predicting Cost/Reliability/Maintainability of Advanced General Aviation Avionics Equipment

    Science.gov (United States)

    Davis, M. R.; Kamins, M.; Mooz, W. E.

    1978-01-01

    A methodology is provided for assisting NASA in estimating the cost, reliability, and maintenance (CRM) requirements for general avionics equipment operating in the 1980's. Practical problems of predicting these factors are examined. The usefulness and short comings of different approaches for modeling coast and reliability estimates are discussed together with special problems caused by the lack of historical data on the cost of maintaining general aviation avionics. Suggestions are offered on how NASA might proceed in assessing cost reliability CRM implications in the absence of reliable generalized predictive models.

  18. Delivering high performance BWR fuel reliably

    Energy Technology Data Exchange (ETDEWEB)

    Schardt, J.F. [GE Nuclear Energy, Wilmington, NC (United States)

    1998-07-01

    Utilities are under intense pressure to reduce their production costs in order to compete in the increasingly deregulated marketplace. They need fuel, which can deliver high performance to meet demanding operating strategies. GE's latest BWR fuel design, GE14, provides that high performance capability. GE's product introduction process assures that this performance will be delivered reliably, with little risk to the utility. (author)

  19. A Study on Performance and Safety Tests of Electrosurgical Equipment.

    Science.gov (United States)

    Tavakoli Golpaygani, A; Movahedi, M M; Reza, M

    2016-09-01

    Modern medicine employs a wide variety of instruments with different physiological effects and measurements. Periodic verifications are routinely used in legal metrology for industrial measuring instruments. The correct operation of electrosurgical generators is essential to ensure patient's safety and management of the risks associated with the use of high and low frequency electrical currents on human body. The metrological reliability of 20 electrosurgical equipment in six hospitals (3 private and 3 public) was evaluated in one of the provinces of Iran according to international and national standards. The achieved results show that HF leakage current of ground-referenced generators are more than isolated generators and the power analysis of only eight units delivered acceptable output values and the precision in the output power measurements was low. Results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially in high risk instruments. It is also necessary to provide training courses for operating staff in the field of meterology in medicine to be acquianted with critical parameters to get accuracy results with operation room equipment.

  20. A Study on Performance and Safety Tests of Electrosurgical Equipment

    Directory of Open Access Journals (Sweden)

    Tavakoli Golpaygani A.

    2016-09-01

    Full Text Available Introduction: Modern medicine employs a wide variety of instruments with different physiological effects and measurements. Periodic verifications are routinely used in legal metrology for industrial measuring instruments. The correct operation of electrosurgical generators is essential to ensure patient’s safety and management of the risks associated with the use of high and low frequency electrical currents on human body. Material and Methods: The metrological reliability of 20 electrosurgical equipment in six hospitals (3 private and 3 public was evaluated in one of the provinces of Iran according to international and national standards. Results: The achieved results show that HF leakage current of ground-referenced generators are more than isolated generators and the power analysis of only eight units delivered acceptable output values and the precision in the output power measurements was low. Conclusion: Results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially in high risk instruments. It is also necessary to provide training courses for operating staff in the field of meterology in medicine to be acquianted with critical parameters to get accuracy results with operation room equipment.

  1. Reliability database development and plant performance improvement effort at Korea Hydro and Nuclear Power Co

    International Nuclear Information System (INIS)

    Oh, S. J.; Hwang, S. W.; Na, J. H.; Lim, H. S.

    2008-01-01

    Nuclear utilities in recent years have focused on improved plant performance and equipment reliability. In U.S., there is a movement toward process integration. Examples are INPO AP-913 equipment reliability program and the standard nuclear performance model developed by NEI. Synergistic effect from an integrated approach can be far greater than as compared to individual effects from each program. In Korea, PSA for all Korean NPPs (Nuclear Power Plants) has been completed. Plant performance monitoring and improvement is an important goal for KHNP (Korea Hydro and Nuclear Power Company) and a risk monitoring system called RIMS has been developed for all nuclear plants. KHNP is in the process of voluntarily implementing maintenance rule program similar to that in U.S. In the future, KHNP would like to expand the effort to equipment reliability program and to achieve highest equipment reliability and improved plant performance. For improving equipment reliability, the current trend is moving toward preventive/predictive maintenance from corrective maintenance. With the emphasis on preventive maintenance, the failure cause and operation history and environment are important. Hence, the development of accurate reliability database is necessary. Furthermore, the database should be updated regularly and maintained as a living program to reflect the current status of equipment reliability. This paper examines the development of reliability database system and its application of maintenance optimization or Risk Informed Application (RIA). (authors)

  2. Reliability of nondestructive testing of metal strength properties for power equipment

    International Nuclear Information System (INIS)

    Bugaj, N.V.; Lebedev, A.A.; Sharko, A.V.

    1985-01-01

    Ultrasonic control which is a constituent part of a complex control system which includes specimen-free (by hardness) tests, random breaking tests and acoustic measurements is stUdied for its reliability with respect to strength properties of power-equipment metal. Quantitative and alternative criteria are developed to estimate quality of elements for power-equipment according to results of metal strength properties. Acoustic control results are presented for ultimate strength in 12Kh1MF-steel

  3. The evaluation of equipment and Instrumentation Reliability Factors on Power Reactor

    International Nuclear Information System (INIS)

    Supriatna, Piping; Karlina, Itjeu; Widagdo, Suharyo; Santosa, Kussigit; Darlis; Sudiyono, Bambang; Yuniyanta, Sasongko; Sudarmin

    1999-01-01

    Equipment and instrumentation reliability on type power reactor control room was determined by its pattern and design. the principle of ergonomy applied on equipment and instrumentation layout in this ABWR type reactor are geometric pattern appropriate with economic body motion, average anthropometry data of operator especially operator hand-reach, range of vision, angle of vision, lighting, color arrangement and harmony as will as operator case in operating the equipment system. Limitation criteria of the parameter mentioned above are based on EPRI NP-3659, NURG 0700, and NUREG/CR-3331 documents. Besides that, the (working) physical environment parameter factor of the control room must be designed in order to fulfil the standard criteria of ergonomic condition based on NUREG-0800. The reliability evaluation of equipment and instrumentation system also occurs observed from man machine interaction side which happen between operator and equipment and instrumentation in the ABWR type power reactor control room. From the MMI analysis can be known the working failure possibility which is caused by the operator. The evaluation result of equipment and instrumentation reliability on ABWR type power reactor control room showed that the design of this ABWR control room is good and fulfils the ergonomy standard criteria have been determined

  4. Research on reliability measures of the main transformer and GIS equipment manufacturing process

    International Nuclear Information System (INIS)

    Wu Honglong

    2014-01-01

    Based on the accidents of the main transformer GIS equipment and the accidents of the high voltage switch equipment, combined with the main transformer switch equipment maintenance experience and electrical theory, the reliability measures of the main transformer GIS equipment during manufacturing stage are studied and improved. Six successful reliability measures are identified: 1) design properly and check the ability of transformer for anti short circuit; 2) choose mature and reliable main transformer HV bushing; 3) choose GIS switch operation mechanism of high quality and reliability; 4) ensure that the insulation margin through tests piece by piece on withstand voltage and partial discharge of the GIS equipment insulation; 5) take test measures such as GIS conductor, shell polishing witness process and full form lightning impulse, to find out and eliminate the defects of abnormal electric field distribution; 6) Anti VFTO design for the main transformer connected with GIS with the voltage of 500 kV should be considered, and its anti VFTO ability to meet the safe operation under VFTO requirements should be checked. This paper proposed 2 new measures: 1) the main transformer insulation material quality standard is determined not only by its high dielectric strength, but more importantly by the homogeneous dielectric electric strength. Insulating Materials with a high and also uniform dielectric strength should be chosen. 2) During the silver-coating stage of the GIS equipment conductor, QC group activities should be organized to ensure that the plating layer quality, and the current lap surface DC resistance measurements should be supervised and witnessed to ensure the quality of the conductor contact surface. These measures are verified in Fuqing project of GIS main transformer equipment manufacturing process, and their effectiveness is proven. (author)

  5. Operational human performance reliability assessment (OHPRA)

    International Nuclear Information System (INIS)

    Haas, P.M.; Swanson, P.J.; Connelly, E.M.

    1993-01-01

    Operational Human Performance Reliability Assessment (OHPRA) is an approach for assessing human performance that is being developed in response to demands from modern process industries for practical and effective tools to assess and improve human performance, and therefore overall system performance and safety. The single most distinguishing feature of the approach is that is defines human performance in open-quotes operationalclose quotes terms. OHPRA is focused not on generation of human error probabilities, but on practical analysis of human performance to aid management in (1) identifying open-quotes fixableclose quotes problems and (2) providing input on the importance and nature of potential improvements. Development of the model in progress uses a unique approach for eliciting expert strategies for assessing performance. A PC-based model incorporating this expertise is planned. A preliminary version of the approach has already been used successfully to identify practical human performance problems in reactor and chemical process plant operations

  6. SGHWR fuel performance, safety and reliability

    International Nuclear Information System (INIS)

    Pickman, D.O.; Inglis, G.H.

    1977-05-01

    The design principles involved in fuel pins and elements need to take account of the sometimes conflicting requirements of safety and reliability. The principal factors involved in this optimisation are discussed and it is shown from fuel irradiation experience in the Winfrith SGHWR that the necessary bias towards safety has not resulted in a reliability level lower than that shown by other successful water reactor designs. Reliability has important economic implications. By a detailed evaluation of SGHWR fuel defects it is shown that very few defects can be shown to be related to design, rating, or burn-up. This demonstrates that economic aspects have not over-ridden necessary criteria that most be met to achieve the desirable reliability level. It is possible that large scale experience on SGHWR fuel may eventually demonstrate that the balance is too much in favour of reliability and consideration may be given to whether design changes favouring economy could be achieved without compromising safety. The safety criteria applied to SGHWR fuel are designed to avoid any possibility of a temperature runaway in any credible accident situation. the philosophy and supporting experimental work programme are outlines and the fuel design features which particularly contribute to maximising safety margins are outlined. Reference is made to the new 60-pin fuel element to be used in the commercial SGHWRs and to its comparison in design and performance aspects with the 36-pin element that has been used to date in the Winfrith SGHWR. (author)

  7. Technical report on reliability assessment of the digital I and C equipment using reliability block diagram

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Young; Hwang, In Koo; Cha, Kyung Ho; Park, Joo Hyun; Choi, Jong Gyun; Lee, Ki Young; Park, Jong Kyun [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-03-01

    As the operational life-time of nuclear power plants being currently developed is increasing with technology improvements, the life-time of instrumentation and control systems is also required to be met to this plant operational period. The electronic devices are usually expected to be available less than for 10 years. Therefore, an appropriate S and PM (surveillance and preventive maintenance) strategy should be established to secure the reliability and availability of the plants. EPRI-URD requires that the mean time between failures caused by any I and C system failure shall be more than 50 operating years. The methodology to access of the mean time between failures of I and C system is included in this report. 35 refs., 19 figs., 3 tabs. (Author)

  8. SGHWR fuel performance, safety and reliability

    International Nuclear Information System (INIS)

    Pickman, D.O.; Inglis, G.H.

    1977-01-01

    The design principles involved in fuel pins and elements need to take account of the sometimes conflicting requirements of performance, safety and reliability. The principal factors involved in this optimisation are discussed and it is shown from fuel irradiation experience in the Winfrith S.G.H.W.R. that the necessary bias toward safety has not resulted in a reliability level lower than that shown by other successful water reactor designs. Reliability has important economic implications and has to be paid for. By a detailed evaluation of S.G.H.W.R. fuel defects it is shown that very few defects can be shown to be related to design, rating or burn-up. This demonstrates that economic aspects have not over-ridden necessary criteria that must be met to achieve the desirable reliability level. It is possible that large-scale experience with S.G.H.W.R. fuel may eventually demonstrate that the balance is too much in favour of reliability and consideration may be given to whether design changes favouring economy could be achieved without compromising safety. The safety criteria applied to S.G.H.W.R. fuel are designed to avoid any possibility of a temperature runaway in any credible accident situation. The philosophy and supporting experimental work programme are outlined and the fuel design features which particularly contribute to maximising safety margins are outlined. Reference is made to new 60 pin fuel element to be used in the commercial S.G.H.W.R.'s and how it compares in design and performance aspects with the 36 pin element that has been used to date in the Winfrith S.G.H.W.R

  9. A summary of methods of predicting reliability life of nuclear equipment with small samples

    International Nuclear Information System (INIS)

    Liao Weixian

    2000-03-01

    Some of nuclear equipment are manufactured in small batch, e.g., 1-3 sets. Their service life may be very difficult to determine experimentally in view of economy and technology. The method combining theoretical analysis with material tests to predict the life of equipment is put forward, based on that equipment consists of parts or elements which are made of different materials. The whole life of an equipment part consists of the crack forming life (i.e., the fatigue life or the damage accumulation life) and the crack extension life. Methods of predicting machine life has systematically summarized with the emphasis on those which use theoretical analysis to substitute large scale prototype experiments. Meanwhile, methods and steps of predicting reliability life have been described by taking into consideration of randomness of various variables and parameters in engineering. Finally, the latest advance and trends of machine life prediction are discussed

  10. Validity and reliability of a home environment inventory for physical activity and media equipment

    Directory of Open Access Journals (Sweden)

    Pereira Mark A

    2008-04-01

    Full Text Available Abstract Background Little is known about how the home environmental supports physical activity and screen media usage. The purpose of this study was to develop and test the reliability and validity of a self-report instrument to comprehensively reflect the availability and accessibility of physical activity and screen media equipment in the home environment. Methods Ten families participated in the initial field testing to provide feedback for instrument development. Thirty one adult participants, each of whom had at least one child 10–17 years old, completed two Physical Activity and Media Inventory (PAMI instruments. The first PAMI was completed simultaneously, but independently, with a research assistant to assess validity. A second PAMI was completed by the participant one week later to assess reliability. Results The adult participants were mostly mothers/female guardians, mean age 38 ± 7.2 years, mostly Caucasian (52%, college educated (65%, living in single family homes (74%. Test-retest reliability was acceptable to strong for all summary variables (physical activity equipment, ICC = 0.76 to 0.99; media equipment, ICC = 0.72 to 0.96. For validation, reports from participants and research assistants were strongly correlated (physical activity, 0.67 – 0.98; media, 0.79 – 0.96. Compared to participants, research assistants reported a greater percentage of physical activity equipment as "in plain view and easy to get to" and a smaller percentage of items as "put away and difficult to get to". Conclusion Our results indicate strong evidence for the reliability and validity of the variables calculated from the PAMI. This self report inventory may be useful in assessing the availability of physical activity and screen media equipment in the home environment and could be used in conjunction with other home assessment tools (food availability, parenting styles and feeding practices to identify obesogenic home environments.

  11. Performance of FACTS equipment in Meshed systems

    Energy Technology Data Exchange (ETDEWEB)

    Lerch, E; Povh, D [Siemens AG, Berlin (Germany)

    1994-12-31

    Modern power electronic devices such as thyristors and GTOs have made it possible to design controllable network elements, which will play a considerable role in ensuring reliable economic operation of transmission systems as a result of their capability to rapidly change active and reactive power. A number of FACTS elements for high-speed active and reactive power control will be described. Control of power system fluctuations in meshed systems by modulation of active and reactive power will be demonstrated using a number of examples. (author) 7 refs., 11 figs.

  12. Increasing reliability of nuclear energy equipment and at nuclear power plants

    International Nuclear Information System (INIS)

    Ochrana, L.

    1997-01-01

    The Institute of Nuclear Energy at the Technical University in Brno cooperates with nuclear power plants in increasing their reliability. The teaching programme is briefly described. The scientific research programme of the Department of Heat and Nuclear Power Energy Equipment in the field of reliability is based on a complex systematic concept securing a high level of reliability. In 1996 the Department prepared a study dealing with the evaluation of the maintenance system in a nuclear power plant. The proposed techniques make it possible to evaluate the reliability and maintenance characteristics of any individual component in a nuclear power plant, and to monitor, record and evaluate data at any given time intervals. (M.D.)

  13. Experience of safety and performance improvement for fuel handling equipment

    International Nuclear Information System (INIS)

    Gyoon Chang, Sang; Hee Lee, Dae

    2014-01-01

    The purpose of this study is to provide experience of safety and performance improvement of fuel handling equipment for nuclear power plants in Korea. The fuel handling equipment, which is used as an important part of critical processes during the refueling outage, has been improved to enhance safety and to optimize fuel handling procedures. Results of data measured during the fuel reloading are incorporated into design changes. The safety and performance improvement for fuel handling equipment could be achieved by simply modifying the components and improving the interlock system. The experience provided in this study can be useful lessons for further improvement of the fuel handling equipment. (authors)

  14. The concepts of leak before break and absolute reliability of NPP equipment and piping

    International Nuclear Information System (INIS)

    Getman, A.F.; Komarov, O.V.; Sokov, L.M.

    1997-01-01

    This paper describes the absolute reliability (AR) concept for ensuring safe operation of nuclear plant equipment and piping. The AR of a pipeline or component is defined as the level of reliability when the probability of an instantaneous double-ended break is near zero. AR analysis has been applied to Russian RBMK and VVER type reactors. It is proposed that analyses required for application of the leak before break concept should be included in AR implementation. The basic principles, methods, and approaches that provide the basis for implementing the AR concept are described

  15. The concepts of leak before break and absolute reliability of NPP equipment and piping

    Energy Technology Data Exchange (ETDEWEB)

    Getman, A.F.; Komarov, O.V.; Sokov, L.M. [and others

    1997-04-01

    This paper describes the absolute reliability (AR) concept for ensuring safe operation of nuclear plant equipment and piping. The AR of a pipeline or component is defined as the level of reliability when the probability of an instantaneous double-ended break is near zero. AR analysis has been applied to Russian RBMK and VVER type reactors. It is proposed that analyses required for application of the leak before break concept should be included in AR implementation. The basic principles, methods, and approaches that provide the basis for implementing the AR concept are described.

  16. Efficiency evaluation of an electronic equipment: availability,reliability and maintenance; Notion d'efficacite d'un equipement electronique: disponibilite, fiabilite et maintenabilite

    Energy Technology Data Exchange (ETDEWEB)

    Guyot, C

    1966-07-01

    This concept of efficiency often called ''system effectiveness'', is presented and analyzed in terms of reliability and maintenance. It allows to define the availability factor of an electronic equipment. A procedure of evaluation is proposed. (A.L.B.)

  17. Development of equipment reliability process using predictive technologies at Hamaoka Nuclear Power Station

    International Nuclear Information System (INIS)

    Taniguchi, Yuji; Sakuragi, Futoshi; Hamada, Seiichi

    2014-01-01

    Development of equipment reliability(ER) process, specifically for predictive maintenance (PdM) technologies integrated condition based maintenance (CBM) process, at Hamaoka Nuclear Power Station is introduced in this paper. Integration of predictive maintenance technologies such as vibration, oil analysis and thermo monitoring is more than important to establish strong maintenance strategies and to direct a specific technical development. In addition, a practical example of CBM is also presented to support the advantage of the idea. (author)

  18. Performance Measurement of Mining Equipments by Utilizing OEE

    Directory of Open Access Journals (Sweden)

    Sermin Elevli

    2010-10-01

    Full Text Available Over the past century, open pit mines have steadily increased their production rate by using larger equipments which requireintensive capital investment. Low commodity prices have forced companies to decrease their unit cost by improving productivity. Oneway to improve productivity is to utilize equipment as effectively as possible. Therefore, the accurate estimation of equipmenteffectiveness is very important so that it can be increased. Overall Equipment Effectiveness (OEE is a well-known measurementmethod, which combines availability, performance and quality, for the evaluation of equipment effectiveness in manufacturing industry.However, there isn’t any study in literature about how to use this metric for mining equipments such as shovel, truck, drilling machineetc. This paper will discuss the application of OEE to measure effectiveness of mining equipment. It identifies causes of time losses forshovel and truck operations and introduces procedure to record time losses. The procedure to estimate OEE of shovels and trucks hasalso been presented via numerical example.

  19. Measurement-based reliability/performability models

    Science.gov (United States)

    Hsueh, Mei-Chen

    1987-01-01

    Measurement-based models based on real error-data collected on a multiprocessor system are described. Model development from the raw error-data to the estimation of cumulative reward is also described. A workload/reliability model is developed based on low-level error and resource usage data collected on an IBM 3081 system during its normal operation in order to evaluate the resource usage/error/recovery process in a large mainframe system. Thus, both normal and erroneous behavior of the system are modeled. The results provide an understanding of the different types of errors and recovery processes. The measured data show that the holding times in key operational and error states are not simple exponentials and that a semi-Markov process is necessary to model the system behavior. A sensitivity analysis is performed to investigate the significance of using a semi-Markov process, as opposed to a Markov process, to model the measured system.

  20. CFC and HFC recycling equipments: Test performances

    International Nuclear Information System (INIS)

    Picini, P.; Caropreso, G.; Cicoli, G.; Posarelli, M.

    1996-12-01

    Actual regulatory conditions about ozone layer depleting chemicals set problems on their disposal and on the management of plants still using illegal CFCs. Anyway fluids that will replace CFCs (i.e. HFCs) will not be allowed to be spread into the atmosphere, due to their high costs and to the greenhouse effect. A viable solution would be the recovery, purification and recycle of contaminated fluids. ENEA (National Agency for New Technology, Energy and the Environment), in cooperation with ICF (Industria Componenti Frigoriferi) Company leader in the field of air refrigerating and conditioning, patented a device able to extract, to clean and to recycle CFC 12 and HFC 134a in the refrigerating systems. This paper presents experimental data from the qualification tests on a device performing the above mentioned operations regarding systems that use HFC 134a as process fluid

  1. Influence of organizational factors on performance reliability

    International Nuclear Information System (INIS)

    Haber, S.B.; O'Brien, J.N.; Metlay, D.S.; Crouch, D.A.

    1991-12-01

    This is the first volume of a two-volume report. Volume 2 will be published at a later date. This report presents the results of a research project conducted by Brookhaven National Laboratory for the United States Nuclear Regulatory Commission, Office of Nuclear Regulatory Research. The purpose of the project was to develop a general methodology to be use in the assessment of the organizational factors which affect performance reliability (safety) in a nuclear power plant. The research described in this report includes the development of the Nuclear Organization and Management Analysis Concept (GNOMIC). This concept characterizes the organizational factors that impact safety performance in a nuclear power plant and identifies some methods for systematically measuring and analyzing the influence of these factors on safety performance. This report is divided into two parts; Part 1 presents an overview of the development of the methodology, while Part 2 provides more details and a technical analysis of the methodological development. Specifically, the results of two demonstration studies, the feasibility of the methodology, and a specific applications for which the methodology was developed are presented

  2. Human Reliability Analysis for In-Tank Precipitation Alignment and Startup of Emergency Purge Ventilation Equipment. Revision 3

    International Nuclear Information System (INIS)

    Shapiro, B.J.; Britt, T.E.

    1994-10-01

    This report documents the methodology used for calculating the human error probability for establishing air based ventilation using emergency purge ventilation equipment on In-Tank Precipitation (ITP) processing tanks 48 and 49 after failure of the nitrogen purge system following a seismic event. The analyses were performed according to THERP (Technique for Human Error Rate Prediction) as described in NUREG/CR-1278-F, ''Handbook of Human Reliability Analysis with Emphasis on Nuclear Power Plant Applications.'' The calculated human error probabilities are provided as input to the Fault Tree Analysis for the ITP Nitrogen Purge System

  3. Air curtain incinerator equipment performance evaluation report

    Energy Technology Data Exchange (ETDEWEB)

    1987-01-01

    About 50 tonnes of oil-contaminated debris and related wood products were successfully incinerated in a 10-h performance evaluation of a mobile air curtain incinerator. The test was conducted to evaluate the incinerator's ability to combust oil-contaminated trash and debris obtained from oil spill sites. The operating principle of the apparatus involves a diesel engine driving an air blower to deliver ca 20,000 scfm of air into a 5-m long manifold angled at a 30{degree} slope into an incineration tank. A bottomhole aerator is lowered to the bottom of the tank and compressed air is injected into the aerator to control burn efficiency. The blower is engaged once the debris in the tank is burning sufficiently after starting a fire in the debris. The air curtain effect created by the air deflecting off the opposite wall from the blower manifold and bouncing off the bottom and up the side of the incineration tank results in repeated combustion of the gases, thereby significantly reducing the degree of visible smoke emission. The unit is capable of incinerating ca 5 tonnes/h and of generating ca 16 m{sup 3}/h of hot water which can be used for flushing spill sites and cleaning shorelines. 12 figs.

  4. Life Cycle Management for Equipments in Nuclear Plants Based on Reliability

    International Nuclear Information System (INIS)

    Wang Dalin; Sun Jinlong

    2012-01-01

    Life cycle management model based on reliability includes two parts: obtaining failure rate function and founding cost-oriented model to solve. It is actually a single objective programming whose optimal solution is the most economical replacement period. Parameters of failure rate function are estimated by Weibull process fitting with the method of maximum likelihood. The objective function of the model is life-cost function where the dependent variable is replacement period T, with the constraints of failure rate or availability. After foundation of LCM model, we solve it to find the optimal replacement period for the equipments. (author)

  5. Life cycle management for equipments in nuclear plants based on reliability and actual conditions

    International Nuclear Information System (INIS)

    Dalin, Wang; Jingquan, Liu; Peng, Liu

    2010-01-01

    Life cycle management model based on reliability includes two parts: obtaining failure rate function and founding cost-oriented model to solve. It is actually a single objective programming whose optimal solution is the most economical replacement period. Parameters of failure rate function are estimated by Weibull process fitting with the method of maximum likelihood. The objective function of the model is life-cost function where the dependent variable is replacement period T, with the constraints of failure rate or availability. After foundation of LCM model, we solve it to find the optimal replacement period for the equipments. (authors)

  6. Assessing the reliability of skilled performance

    International Nuclear Information System (INIS)

    Dougherty, E.M.; Collins, E.P.

    1996-01-01

    In some high-hazard military tasks, precision of motor skills is crucial to avoid a risk-sensitive drop or other mishap. Sparse data supports a basic level of reliability for this activity seemingly much lower than typical, individual action, slip-mode errors would yield. A typical occurrence failure rate seems to be of the order of 1 x 10 -5 per opportunity. A speculation is tendered that this represents a difference in kind; that the reliability of skills is a different taxon than previously called out in the typical scheme of human reliability

  7. Human reliability analysis for In-Tank Precipitation alignment and startup of emergency purge ventilation equipment

    International Nuclear Information System (INIS)

    Olsen, L.M.

    1993-08-01

    This report documents the methodology used for calculating the human error probability for establishing air based ventilation using emergency purge ventilation equipment on In-Tank Precipitation (ITP) processing tanks 48 and 49 after a failure of the nitrogen purge system following a seismic event. The analyses were performed according to THERP (Technique for Human Error Rate Prediction). The calculated human error probabilities are provided as input to the Fault Tree Analysis for the ITP Nitrogen Purge System. The analysis assumes a seismic event initiator leading to establishing air based ventilation on the ITP processing tanks 48 and 49. At the time of this analysis only the tanks and the emergency purge ventilation equipment are seismically qualified. Consequently, onsite and offsite power is assumed to be unavailable and all operator control actions are to be performed locally on the tank top. Assumptions regarding procedures, staffing, equipment locations, equipment tagging, equipment availability, and training were made and are documented in this report. The human error probability for establishing air based ventilation using the emergency purge ventilation equipment on In-Tank Precipitation processing tanks 48 and 49 after a failure of the nitrogen purge system following a seismic event is 4.2E-6 (median value on the lognormal scale). It is important to note that this result is predicated on the implementation of all of the assumptions listed in the ''Assumptions'' section of this report. This analysis was not based on the current conditions in ITP. The analysis is to be used as a tool to aid ITP operations personnel in achieving the training, procedural, and operational goals outlined in this document

  8. Use of eye tracking equipment for human reliability analysis applied to complex system operations

    International Nuclear Information System (INIS)

    Pinheiro, Andre Ricardo Mendonça; Prado, Eugenio Anselmo Pessoa do; Martins, Marcelo Ramos

    2017-01-01

    This article will discuss the preliminary results of an evaluation methodology for the analysis and quantification of manual character errors (human), by monitoring cognitive parameters and skill levels in the operation of a complex control system based on parameters provided by a eye monitoring equipment (Eye Tracker). The research was conducted using a simulator (game) that plays concepts of operation of a nuclear reactor with a split sample for evaluation of aspects of learning, knowledge and standard operating within the context addressed. bridge operators were monitored using the EYE TRACKING, eliminating the presence of the analyst in the evaluation of the operation, allowing the analysis of the results by means of multivariate statistical techniques within the scope of system reliability. The experiments aim to observe state change situations such as stops and scheduled departures, incidents assumptions and common operating characteristics. Preliminary results of this research object indicate that technical and cognitive aspects can contribute to improving the reliability of the available techniques in human reliability, making them more realistic both in the context of quantitative approaches to regulatory and training purposes, as well as reduced incidence of human error. (author)

  9. Use of eye tracking equipment for human reliability analysis applied to complex system operations

    Energy Technology Data Exchange (ETDEWEB)

    Pinheiro, Andre Ricardo Mendonça; Prado, Eugenio Anselmo Pessoa do; Martins, Marcelo Ramos, E-mail: andrericardopinheiro@usp.br, E-mail: eugenio.prado@labrisco.usp.br, E-mail: mrmatins@usp.br [Universidade de Sao Paulo (LABRISCO/USP), Sao Paulo, SP (Brazil). Lab. de Análise, Avaliação e Gerenciamento de Risco

    2017-07-01

    This article will discuss the preliminary results of an evaluation methodology for the analysis and quantification of manual character errors (human), by monitoring cognitive parameters and skill levels in the operation of a complex control system based on parameters provided by a eye monitoring equipment (Eye Tracker). The research was conducted using a simulator (game) that plays concepts of operation of a nuclear reactor with a split sample for evaluation of aspects of learning, knowledge and standard operating within the context addressed. bridge operators were monitored using the EYE TRACKING, eliminating the presence of the analyst in the evaluation of the operation, allowing the analysis of the results by means of multivariate statistical techniques within the scope of system reliability. The experiments aim to observe state change situations such as stops and scheduled departures, incidents assumptions and common operating characteristics. Preliminary results of this research object indicate that technical and cognitive aspects can contribute to improving the reliability of the available techniques in human reliability, making them more realistic both in the context of quantitative approaches to regulatory and training purposes, as well as reduced incidence of human error. (author)

  10. MYRRHA cryogenic system study on performances and reliability requirements

    International Nuclear Information System (INIS)

    Junquera, T.; Chevalier, N.R.; Thermeau, J.P.; Medeiros Romao, L.; Vandeplassche, D.

    2015-01-01

    A precise evaluation of the cryogenic requirements for accelerator-driven system such as the MYRRHA project has been performed. In particular, operation temperature, thermal losses, and required cryogenic power have been evaluated. A preliminary architecture of the cryogenic system including all its major components, as well as the principles for the cryogenic fluids distribution has been proposed. A detailed study on the reliability aspects has also been initiated. This study is based on the reliability of large cryogenic systems used for accelerators like HERA, LHC or SNS Linac. The requirements to guarantee good cryogenic system availability can be summarised as follows: 1) Mean Time Between Maintenance (MTBM) should be > 8 000 hours; 2) Valves, heat exchangers and turbines are particularly sensitive elements to impurities (dust, oil, gases), improvements are necessary to keep a minimal level in these components; 3) Redundancy studies for all elements containing moving/vibrating parts (turbines, compressors, including their respective bearings and seal shafts) are necessary; 4) Periodic maintenance is mandatory: oil checks, control of screw compressors every 10.000-15.000 hours, vibration surveillance programme, etc; 5) Special control and maintenance of utilities equipment (supply of cooling water, compressed air and electrical supply) is necessary; 6) Periodic vacuum checks to identify leakage appearance such as insulation vacuum of transfer lines and distribution boxes are necessary; 7) Easily exchangeable cold compressors are required

  11. Applications of Human Performance Reliability Evaluation Concepts and Demonstration Guidelines

    Science.gov (United States)

    1977-03-15

    ship stops dead in the water and the AN/SQS-26 operator recommends a new heading (000°). At T + 14 minutes, the target ship begins a hard turn to...Various Simulated Conditions 82 9 Hunan Reliability for Each Simulated Operator (Baseline Run) 83 10 Human and Equipment Availabilit / under

  12. Major factors in critical equipment reliability - Auxiliary systems; The development of an auxiliary system

    International Nuclear Information System (INIS)

    Forsthoffer, W.E.

    1992-01-01

    In this article, the author details the development of an actual auxiliary system in order to fully understand the function of each major component and how it contributes to the total operation and reliability of the system. Only after the function of an auxiliary system is thoroughly understood, can one proceed to discuss specifications, design audits, testing, operation and preventive maintenance. The application selected will be to develop a pressurized lubrication and steam turbine control oil system for the critical equipment unit. This example was selected since many readers will be familiar with this type and because it provides a good foundation towards understanding fluid sealing systems. In the exercise that follow, he will define the system requirements and determine the system parameters. This information will then be used for component sizing

  13. Performance and reliability of LWR fuel

    International Nuclear Information System (INIS)

    Bairiot, H.; Deramaix, P.; Vandenberg, C.

    1977-01-01

    The main requirements for fuel reloads are: good reliability, minimum fuel cycle costs and flexibility of operation. Fulfilling these goals requires a background of experience. The approach to the acquisition of this experience in the particular case of BN has included over the last 15 years a proper development and cross-checking of the design methods and criteria, a continuous updating of the drawings and specifications and the qualification of adequate fabrication plants. This approach can best be outlined on the basis of the gradual implementation of the modern features of the LWR fuel. The first fuel clad with stainless steel was loaded in the BR 3 (11 MWe) in 1969 and later on (since 1974) in the SENA plant (310 MWe). Similarly, Zircaloy 4 cladding was first introduced in a reactor reload in 1969 as autoclaved cladding and later on (in 1971) the autoclaving was suppressed for the further reloads. Zircaloy 2 was loaded in DODEWAARD (51.5 MWe) in 1970. The first demonstration assembly in a PWR was a Pu-island assembly loaded in the BR 3 in 1963. It was followed by an all-Pu assembly in the same reactor in 1965 and by the loading of Pu fuels in four prototype assemblies in GARIGLIANO (160 MWe) in 1968. A full reload incorporating Pu fuel has been experienced by the supply of fuel for GARIGLIANO (BOL: 1975) and for BR 3 (BOL: 1972 and 1976). While in the early sixties the brazed design was still being utilized, the first assembly incorporating grids with springs was introduced in BR 3 in 1963. The first Inconel grids were loaded in the same reactor in 1969 and the first Zircaloy grids in 1972 (the first Zr grid has been loaded in a BWR in 1973). The experience covered successively the shrouded design (BOL: 1963), the shroudless design (BOL: 1969), a BWR assembly (BOL: 1971), a typical RCC assembly first with large diameter fuel rods (1972) and later on with small diameter fuel rods (1974). The experience on the reactivity control covered successively diluted

  14. Design, construction and testing of replacement nuclear coolant pump stators to meet today's equipment reliability expectations

    International Nuclear Information System (INIS)

    Fostier, L.; Howell, D.

    2005-01-01

    The reliability expectations of equipment and components in today's nuclear power plant are much greater than three or more decades ago when nuclear plants were first constructed due to economic impact of a failure. Very few components in a pressurized water reactor plant can have as much impact of the plants capacity factor as a catastrophic failure of a reactor coolant pump winding. This paper describes the maintenance approach taken by one North American utility in attempt to preclude such failures. The paper will discuss the challenges of the reactor coolant pump application and the enhancements made in the winding design and construction by the supplier to address failure mechanisms so as to better meet present reliability expectations in accordance with dedicated specifications. The paper will also present the in-process and final testing requirements and limits imposed in an attempt to ensure quality of the machine windings, along with selected test results from the stators that have been designed and constructed to these specifications to date. (author)

  15. Multivariate performance reliability prediction in real-time

    International Nuclear Information System (INIS)

    Lu, S.; Lu, H.; Kolarik, W.J.

    2001-01-01

    This paper presents a technique for predicting system performance reliability in real-time considering multiple failure modes. The technique includes on-line multivariate monitoring and forecasting of selected performance measures and conditional performance reliability estimates. The performance measures across time are treated as a multivariate time series. A state-space approach is used to model the multivariate time series. Recursive forecasting is performed by adopting Kalman filtering. The predicted mean vectors and covariance matrix of performance measures are used for the assessment of system survival/reliability with respect to the conditional performance reliability. The technique and modeling protocol discussed in this paper provide a means to forecast and evaluate the performance of an individual system in a dynamic environment in real-time. The paper also presents an example to demonstrate the technique

  16. Development of KSC program for investigating and generating field failure rates. Reliability handbook for ground support equipment

    Science.gov (United States)

    Bloomquist, C. E.; Kallmeyer, R. H.

    1972-01-01

    Field failure rates and confidence factors are presented for 88 identifiable components of the ground support equipment at the John F. Kennedy Space Center. For most of these, supplementary information regarding failure mode and cause is tabulated. Complete reliability assessments are included for three systems, eight subsystems, and nine generic piece-part classifications. Procedures for updating or augmenting the reliability results are also included.

  17. A method for performance assessment of medical radioisotope equipment

    International Nuclear Information System (INIS)

    Kerin, T.; Slavtchev, Ath.; Nedeltchev, M.; Kjurktchiev, T.

    1984-01-01

    A variety of tests and procedures exist for the performance assessment of radioisotope diagnostic equipment. The complex performance index which has been introduced to date is based on an heuristic approach. The present work tries to interconnect algorithmically the most important factors as the influence of the measurement geometry, the statistic peculiarities for lower activities and the information loss at high count rates. All this is reflected in a criterion which integrates the spatial resolution, the effective detector's field of vision, the radionuclide's sensitivity, the background count rate and the effective dead-time of the system under investigation. (Auth.)

  18. Equipment and performance upgrade of compact nuclear simulator

    International Nuclear Information System (INIS)

    Park, J. C.; Kwon, K. C.; Lee, D. Y.; Hwang, I. K.; Park, W. M.; Cha, K. H.; Song, S. J.; Lee, J. W.; Kim, B. G.; Kim, H. J.

    1999-01-01

    The simulator at Nuclear Training Center in KAERI became old and has not been used effectively for nuclear-related training and researches due to the problems such as aging of the equipment, difficulties in obtaining consumables and their high cost, and less personnel available who can handle the old equipment. To solve the problems, this study was performed for recovering the functions of the simulator through the technical design and replacement of components with new ones. As results of this study, our test after the replacement showed the same simulation status as the previous one, and new graphic displays added to the simulator was effective for the training and easy for maintenance. This study is meaningful as demonstrating the way of upgrading nuclear training simulators that lost their functioning due to the obsolescence of simulators and the unavailability of components

  19. Performance reliability prediction for thermal aging based on kalman filtering

    International Nuclear Information System (INIS)

    Ren Shuhong; Wen Zhenhua; Xue Fei; Zhao Wensheng

    2015-01-01

    The performance reliability of the nuclear power plant main pipeline that failed due to thermal aging was studied by the performance degradation theory. Firstly, through the data obtained from the accelerated thermal aging experiments, the degradation process of the impact strength and fracture toughness of austenitic stainless steel material of the main pipeline was analyzed. The time-varying performance degradation model based on the state space method was built, and the performance trends were predicted by using Kalman filtering. Then, the multi-parameter and real-time performance reliability prediction model for the main pipeline thermal aging was developed by considering the correlation between the impact properties and fracture toughness, and by using the stochastic process theory. Thus, the thermal aging performance reliability and reliability life of the main pipeline with multi-parameter were obtained, which provides the scientific basis for the optimization management of the aging maintenance decision making for nuclear power plant main pipelines. (authors)

  20. Facility/equipment performance evaluation using microcomputer simulation analysis

    International Nuclear Information System (INIS)

    Chockie, A.D.; Hostick, C.J.

    1985-08-01

    A computer simulation analysis model was developed at the Pacific Northwest Laboratory to assist in assuring the adequacy of the Monitored Retrievable Storage facility design to meet the specified spent nuclear fuel throughput requirements. The microcomputer-based model was applied to the analysis of material flow, equipment capability and facility layout. The simulation analysis evaluated uncertainties concerning both facility throughput requirements and process duration times as part of the development of a comprehensive estimate of facility performance. The evaluations provided feedback into the design review task to identify areas where design modifications should be considered

  1. Performativity and the Politics of Equipping for Calculation

    DEFF Research Database (Denmark)

    Henriksen, Lasse Folke

    2013-01-01

    This article argues that the concept of performativity deepens our understanding of contemporary, expertise-driven processes of global economic governance. Tracing the World Bank's role in constructing a global market for microfinance, the paper suggests that the World Bank was instrumental...... in translating selected parts of economic models into practice, thereby changing microfinance practices globally. Socio-technical networks centered on the World Bank were created to equip actors to become part of a global market, which incorporated not only donors but also commercial investors. The paper makes...

  2. Reliable predictions of waste performance in a geologic repository

    International Nuclear Information System (INIS)

    Pigford, T.H.; Chambre, P.L.

    1985-08-01

    Establishing reliable estimates of long-term performance of a waste repository requires emphasis upon valid theories to predict performance. Predicting rates that radionuclides are released from waste packages cannot rest upon empirical extrapolations of laboratory leach data. Reliable predictions can be based on simple bounding theoretical models, such as solubility-limited bulk-flow, if the assumed parameters are reliably known or defensibly conservative. Wherever possible, performance analysis should proceed beyond simple bounding calculations to obtain more realistic - and usually more favorable - estimates of expected performance. Desire for greater realism must be balanced against increasing uncertainties in prediction and loss of reliability. Theoretical predictions of release rate based on mass-transfer analysis are bounding and the theory can be verified. Postulated repository analogues to simulate laboratory leach experiments introduce arbitrary and fictitious repository parameters and are shown not to agree with well-established theory. 34 refs., 3 figs., 2 tabs

  3. Reliability of equipments and theory of frequency statistics and Bayesian decision

    International Nuclear Information System (INIS)

    Procaccia, H.; Clarotti, C.A.

    1992-01-01

    The rapid development of Bayesian techniques use in the domain of industrial risk is a recent phenomenon linked to the development of powerful computers. These techniques involve a reasoning well adapted to experimental logics, based on the dynamical knowledge enrichment with experience data. In the framework of reliability studies and statistical decision making, these methods differ slightly from the methods commonly used to evaluate the reliability of systems and from classical theoretical frequency statistics. This particular approach is described in this book and illustrated with many examples of application (power plants, pressure vessels, industrial installations etc..). These examples generally concern the risk management in the cases where the application of rules and the respect of norms become insufficient. It is now well known that the risk cannot be reduced to zero and that its evaluation must be performed using statistics, taking into account the possible accident processes and also the investments necessary to avoid them (service life, failure, maintenance costs and availability of materials). The result is the optimizing of a decision process about rare or uncertain events. (J.S.)

  4. Establishing reliability of performance indicator of sepak takraw ...

    African Journals Online (AJOL)

    The aim of this study is to establish the necessary reliability in the notational analysis of sepak takraw. Two performance analysts were recruited to help in the collection of the data. The performances were analyzed based on the main performance indicators relevant to the demand of the game. Cronbach's alpha and ...

  5. The development of a reliable amateur boxing performance analysis template.

    Science.gov (United States)

    Thomson, Edward; Lamb, Kevin; Nicholas, Ceri

    2013-01-01

    The aim of this study was to devise a valid performance analysis system for the assessment of the movement characteristics associated with competitive amateur boxing and assess its reliability using analysts of varying experience of the sport and performance analysis. Key performance indicators to characterise the demands of an amateur contest (offensive, defensive and feinting) were developed and notated using a computerised notational analysis system. Data were subjected to intra- and inter-observer reliability assessment using median sign tests and calculating the proportion of agreement within predetermined limits of error. For all performance indicators, intra-observer reliability revealed non-significant differences between observations (P > 0.05) and high agreement was established (80-100%) regardless of whether exact or the reference value of ±1 was applied. Inter-observer reliability was less impressive for both analysts (amateur boxer and experienced analyst), with the proportion of agreement ranging from 33-100%. Nonetheless, there was no systematic bias between observations for any indicator (P > 0.05), and the proportion of agreement within the reference range (±1) was 100%. A reliable performance analysis template has been developed for the assessment of amateur boxing performance and is available for use by researchers, coaches and athletes to classify and quantify the movement characteristics of amateur boxing.

  6. Reliability analysis of the automatic control and power supply of reactor equipment

    International Nuclear Information System (INIS)

    Monori, Pal; Nagy, J.A.; Meszaros, Zoltan; Konkoly, Laszlo; Szabo, Antal; Nagy, Laszlo

    1988-01-01

    Based on reliability analysis the shortcomings of nuclear facilities are discovered. Fault tree types constructed for the technology of automatic control and for power supply serve as input data of the ORCHARD 2 computer code. In order to charaterize the reliability of the system, availability, failure rates and time intervals between failures are calculated. The results of the reliability analysis of the feedwater system of the Paks Nuclear Power Plant showed that the system consisted of elements of similar reliabilities. (V.N.) 8 figs.; 3 tabs

  7. Cycle chemistry monitoring system as means of improving the reliability of the equipment at the power plants

    Science.gov (United States)

    Yegoshina, O. V.; Voronov, V. N.; Yarovoy, V. O.; Bolshakova, N. A.

    2017-11-01

    There are many problems in domestic energy at the present that require urgent solutions in the near future. One of these problems - the aging of the main and auxiliary equipment. Wear of equipment is the cause of decrease reliability and efficiency of power plants. Reliability of the equipment are associated with the introduction of cycle chemistry monitoring system. The most damageable equipment’s are boilers (52.2 %), turbines (12.6 %) and heating systems (12.3 %) according to the review of failure rate on the power plants. The most part of the damageability of the boiler is heated surfaces (73.2 %). According to the Russian technical requirements, the monitoring systems are responsible to reduce damageability the boiler heating surfaces and to increase the reliability of the equipment. All power units capacity of over 50 MW are equipped with cycle chemistry monitoring systems in order to maintain water chemistry within operating limits. The main idea of cycle chemistry monitoring systems is to improve water chemistry at power plants. According to the guidelines, cycle chemistry monitoring systems of a single unit depends on its type (drum or once-through boiler) and consists of: 20…50 parameters of on-line chemical analyzers; 20…30 «grab» sample analyses (daily) and about 15…20 on-line monitored operating parameters. The operator of modern power plant uses with many data at different points of steam/water cycle. Operators do not can estimate quality of the cycle chemistry due to the large volume of daily and every shift information and dispersion of data, lack of systematization. In this paper, an algorithm for calculating the quality index developed for improving control the water chemistry of the condensate, feed water and prevent scaling and corrosion in the steam/water cycle.

  8. Flash memories economic principles of performance, cost and reliability optimization

    CERN Document Server

    Richter, Detlev

    2014-01-01

    The subject of this book is to introduce a model-based quantitative performance indicator methodology applicable for performance, cost and reliability optimization of non-volatile memories. The complex example of flash memories is used to introduce and apply the methodology. It has been developed by the author based on an industrial 2-bit to 4-bit per cell flash development project. For the first time, design and cost aspects of 3D integration of flash memory are treated in this book. Cell, array, performance and reliability effects of flash memories are introduced and analyzed. Key performance parameters are derived to handle the flash complexity. A performance and array memory model is developed and a set of performance indicators characterizing architecture, cost and durability is defined.   Flash memories are selected to apply the Performance Indicator Methodology to quantify design and technology innovation. A graphical representation based on trend lines is introduced to support a requirement based pr...

  9. Beam reliability and equipment downtime tracking how Lansce closes the loop

    International Nuclear Information System (INIS)

    Callaway, N.T.; Ryder, R.D.

    2003-01-01

    LANSCE uses a semi-automated accounting system to track how well we meet our stated beam delivery goals. When an equipment failure prevents delivery of the desired beam to our customers, the first order cause is identified and an accurate measurement of the downtime is recorded. For equipment downtimes of significant duration, we investigate the causes and make recommendations that will hopefully eliminate or mitigate the impact of similar downtimes in the future. (authors)

  10. Performance and Reliability of Wind Turbines: A Review

    Directory of Open Access Journals (Sweden)

    Sebastian Pfaffel

    2017-11-01

    Full Text Available Performance (availability and yield and reliability of wind turbines can make the difference between success and failure of wind farm projects and these factors are vital to decrease the cost of energy. During the last years, several initiatives started to gather data on the performance and reliability of wind turbines on- and offshore and published findings in different journals and conferences. Even though the scopes of the different initiatives are similar, every initiative follows a different approach and results are therefore difficult to compare. The present paper faces this issue, collects results of different initiatives and harmonizes the results. A short description and assessment of every considered data source is provided. To enable this comparison, the existing reliability characteristics are mapped to a system structure according to the Reference Designation System for Power Plants (RDS-PP®. The review shows a wide variation in the performance and reliability metrics of the individual initiatives. Especially the comparison on onshore wind turbines reveals significant differences between the results. Only a few publications are available on offshore wind turbines and the results show an increasing performance and reliability of offshore wind turbines since the first offshore wind farms were erected and monitored.

  11. Material and design considerations of FBGA reliability performance

    International Nuclear Information System (INIS)

    Lee, Teck Kheng; Ng, T.C.; Chai, Y.M.

    2004-01-01

    FBGA package reliability is usually assessed through the conventional approaches of die attach and mold compound material optimization. However, with the rapid changes and fast-moving pace of electronic packaging and the introduction of new soldermask and core materials, substrate design has also become a critical factor in determining overall package reliability. The purpose of this paper is to understand the impact design and soldermask material of a rigid substrate on overall package reliability. Three different soldermask patterns with a matrix of different die attach, mold compound, and soldermask materials are assessed using the moisture sensitivity test (MST). Package reliability is also assessed through the use of temperature cycling (T/C) at conditions 'B' and 'C'. For material optimization, three different mold compounds and die attach materials are used. Material adhesion between different die attach materials and soldermask materials are obtained through die shear performed at various temperatures and preset moisture conditions. A study correlating the different packaging material properties and their relative adhesion strengths with overall package reliability in terms of both MST and T/C performance was performed. Soldermask design under the die pads was found to affect package reliability. For example, locating vias at the edge of the die is not desirable because the vias acts as initiation point for delamination and moisture-induced failure. Through die shear testing, soldermask B demonstrated higher adhesion properties compared to soldermask A across several packaging materials and enhanced the overall package reliability in terms of both MST and T/C performance. Both MST JEDEC level 1 and the T/C of 'B' and 'C' at 1000 cycles have been achieved through design and package material optimization

  12. Material and design considerations of FBGA reliability performance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Teck Kheng; Ng, T.C.; Chai, Y.M

    2004-09-01

    FBGA package reliability is usually assessed through the conventional approaches of die attach and mold compound material optimization. However, with the rapid changes and fast-moving pace of electronic packaging and the introduction of new soldermask and core materials, substrate design has also become a critical factor in determining overall package reliability. The purpose of this paper is to understand the impact design and soldermask material of a rigid substrate on overall package reliability. Three different soldermask patterns with a matrix of different die attach, mold compound, and soldermask materials are assessed using the moisture sensitivity test (MST). Package reliability is also assessed through the use of temperature cycling (T/C) at conditions 'B' and 'C'. For material optimization, three different mold compounds and die attach materials are used. Material adhesion between different die attach materials and soldermask materials are obtained through die shear performed at various temperatures and preset moisture conditions. A study correlating the different packaging material properties and their relative adhesion strengths with overall package reliability in terms of both MST and T/C performance was performed. Soldermask design under the die pads was found to affect package reliability. For example, locating vias at the edge of the die is not desirable because the vias acts as initiation point for delamination and moisture-induced failure. Through die shear testing, soldermask B demonstrated higher adhesion properties compared to soldermask A across several packaging materials and enhanced the overall package reliability in terms of both MST and T/C performance. Both MST JEDEC level 1 and the T/C of 'B' and 'C' at 1000 cycles have been achieved through design and package material optimization.

  13. Reliability-based performance simulation for optimized pavement maintenance

    International Nuclear Information System (INIS)

    Chou, Jui-Sheng; Le, Thanh-Son

    2011-01-01

    Roadway pavement maintenance is essential for driver safety and highway infrastructure efficiency. However, regular preventive maintenance and rehabilitation (M and R) activities are extremely costly. Unfortunately, the funds available for the M and R of highway pavement are often given lower priority compared to other national development policies, therefore, available funds must be allocated wisely. Maintenance strategies are typically implemented by optimizing only the cost whilst the reliability of facility performance is neglected. This study proposes a novel algorithm using multi-objective particle swarm optimization (MOPSO) technique to evaluate the cost-reliability tradeoff in a flexible maintenance strategy based on non-dominant solutions. Moreover, a probabilistic model for regression parameters is employed to assess reliability-based performance. A numerical example of a highway pavement project is illustrated to demonstrate the efficacy of the proposed MOPSO algorithms. The analytical results show that the proposed approach can help decision makers to optimize roadway maintenance plans. - Highlights: →A novel algorithm using multi-objective particle swarm optimization technique. → Evaluation of the cost-reliability tradeoff in a flexible maintenance strategy. → A probabilistic model for regression parameters is employed to assess reliability-based performance. → The proposed approach can help decision makers to optimize roadway maintenance plans.

  14. Reliability-based performance simulation for optimized pavement maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Jui-Sheng, E-mail: jschou@mail.ntust.edu.tw [Department of Construction Engineering, National Taiwan University of Science and Technology (Taiwan Tech), 43 Sec. 4, Keelung Rd., Taipei 106, Taiwan (China); Le, Thanh-Son [Department of Construction Engineering, National Taiwan University of Science and Technology (Taiwan Tech), 43 Sec. 4, Keelung Rd., Taipei 106, Taiwan (China)

    2011-10-15

    Roadway pavement maintenance is essential for driver safety and highway infrastructure efficiency. However, regular preventive maintenance and rehabilitation (M and R) activities are extremely costly. Unfortunately, the funds available for the M and R of highway pavement are often given lower priority compared to other national development policies, therefore, available funds must be allocated wisely. Maintenance strategies are typically implemented by optimizing only the cost whilst the reliability of facility performance is neglected. This study proposes a novel algorithm using multi-objective particle swarm optimization (MOPSO) technique to evaluate the cost-reliability tradeoff in a flexible maintenance strategy based on non-dominant solutions. Moreover, a probabilistic model for regression parameters is employed to assess reliability-based performance. A numerical example of a highway pavement project is illustrated to demonstrate the efficacy of the proposed MOPSO algorithms. The analytical results show that the proposed approach can help decision makers to optimize roadway maintenance plans. - Highlights: > A novel algorithm using multi-objective particle swarm optimization technique. > Evaluation of the cost-reliability tradeoff in a flexible maintenance strategy. > A probabilistic model for regression parameters is employed to assess reliability-based performance. > The proposed approach can help decision makers to optimize roadway maintenance plans.

  15. Performance of the standard FAIR equipment controller prototype

    International Nuclear Information System (INIS)

    Rauch, S.; Baer, R.C.; Panschow, W.; Thieme, M.

    2012-01-01

    For the control system of the new FAIR accelerator facility a standard equipment controller, the Scalable Control Unit (SCU), is presently under development. First prototypes have already been tested in real applications. The controller combines an *86 COM Express TM Board and an Altera Arria TM II FPGA. Over a parallel bus interface called the SCU bus, up to 12 slave boards can be controlled. Communication between CPU and FPGA is done by a PCIe link. We discuss the real time behaviour between the Linux OS and the FPGA Hardware. For the test, a Front-End Software Architecture (FESA) class, running under Linux, communicates with the PCIe bridge in the FPGA. Although we are using PCIe only for single 32 bit wide accesses to the FPGA address space, the performance still seems sufficient. The tests showed an average response time to IRQs of 50 μs with a 1.6 GHz Intel Atom CPU. This includes the context change to the FESA user space application and the reply back to the FPGA. Further topics are the bandwidth of the PCIe link for single/burst transfers and the performance of the SCU bus communication. (authors)

  16. Performance of Very Small Robotic Fish Equipped with CMOS Camera

    Directory of Open Access Journals (Sweden)

    Yang Zhao

    2015-10-01

    Full Text Available Underwater robots are often used to investigate marine animals. Ideally, such robots should be in the shape of fish so that they can easily go unnoticed by aquatic animals. In addition, lacking a screw propeller, a robotic fish would be less likely to become entangled in algae and other plants. However, although such robots have been developed, their swimming speed is significantly lower than that of real fish. Since to carry out a survey of actual fish a robotic fish would be required to follow them, it is necessary to improve the performance of the propulsion system. In the present study, a small robotic fish (SAPPA was manufactured and its propulsive performance was evaluated. SAPPA was developed to swim in bodies of freshwater such as rivers, and was equipped with a small CMOS camera with a wide-angle lens in order to photograph live fish. The maximum swimming speed of the robot was determined to be 111 mm/s, and its turning radius was 125 mm. Its power consumption was as low as 1.82 W. During trials, SAPPA succeeded in recognizing a goldfish and capturing an image of it using its CMOS camera.

  17. Implementation of the project of equipment reliability in the nuclear power plant of Laguna Verde; Implementacion del proyecto de confiabilidad de equipo en la Central Nucleoelectrica Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Rios O, J. E.; Martinez L, A. G. [CFE, Central Laguna Verde, Subgerencia General de Operacion, Veracruz (Mexico)]. e-mail: jrios@cfe.gob.mx

    2008-07-01

    A equipment is reliable if it fulfills the function for which was designed and when it is required. To implement a project of reliability in a nuclear power plant this associate to a process of continuous analysis of the operation, of the conditions and faults of the equipment. The analysis of the operation of a system, of the equipment of the same faults and the parts that integrate to equipment take to identify the potential causes of faults. The predictive analysis on components and equipment allow to rectify and to establish guides to optimize the maintenance and to guarantee the reliability and function of the same ones. The reliability in the equipment is without place to doubts a wide project that embraces from the more small component of the equipment going by the proof of the parts of reserve, the operation conditions until the operative techniques of analysis. Without place of doubt for a nuclear power plant the taking of decisions based on the reliability of their systems and equipment will be the appropriate for to assure the operation and reliability of the same one. In this work would appear the project of reliability its processes, criteria, indicators action of improvement and the interaction of the different disciplines from the Nuclear Power Plant of Laguna Verde like a fundamental point for it put in operation. (Author)

  18. Engineering and Design: Reliability Analysis of Navigation Lock and Dam Mechanical and Electrical Equipment

    National Research Council Canada - National Science Library

    Beranek, Dwight

    2001-01-01

    This engineer technical letter (ETL) provides guidance for assessing the reliability of mechanical and electrical systems of navigation locks and dams and for establishing an engineering basis for major rehabilitation investment decisions...

  19. Developing safety performance functions incorporating reliability-based risk measures.

    Science.gov (United States)

    Ibrahim, Shewkar El-Bassiouni; Sayed, Tarek

    2011-11-01

    Current geometric design guides provide deterministic standards where the safety margin of the design output is generally unknown and there is little knowledge of the safety implications of deviating from these standards. Several studies have advocated probabilistic geometric design where reliability analysis can be used to account for the uncertainty in the design parameters and to provide a risk measure of the implication of deviation from design standards. However, there is currently no link between measures of design reliability and the quantification of safety using collision frequency. The analysis presented in this paper attempts to bridge this gap by incorporating a reliability-based quantitative risk measure such as the probability of non-compliance (P(nc)) in safety performance functions (SPFs). Establishing this link will allow admitting reliability-based design into traditional benefit-cost analysis and should lead to a wider application of the reliability technique in road design. The present application is concerned with the design of horizontal curves, where the limit state function is defined in terms of the available (supply) and stopping (demand) sight distances. A comprehensive collision and geometric design database of two-lane rural highways is used to investigate the effect of the probability of non-compliance on safety. The reliability analysis was carried out using the First Order Reliability Method (FORM). Two Negative Binomial (NB) SPFs were developed to compare models with and without the reliability-based risk measures. It was found that models incorporating the P(nc) provided a better fit to the data set than the traditional (without risk) NB SPFs for total, injury and fatality (I+F) and property damage only (PDO) collisions. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Proceedings of the 1998 Photovoltaic Performance and Reliability Workshop

    International Nuclear Information System (INIS)

    Kroposki, B.

    1998-01-01

    This proceedings is the compilation of all papers presented at the 11th PV Performance and Reliability Workshop held at the Doubletree Hotel in Cocoa Beach, Florida, on November 3-5, 1998. The workshop was hosted by the Florida Solar Energy Center. This year's workshop included presentations from 29 speakers and had 110 attendees

  1. Reliable and Valid Assessment of Clinical Bronchoscopy Performance

    DEFF Research Database (Denmark)

    Konge, Lars; Larsen, Klaus Richter; Clementsen, Paul

    2012-01-01

    : The interrater reliability was high, with Cronbach's a = 0.86. Assessment of 3 bronchoscopies by a single rater had a generalizability coefficient of 0.84. The correlation between experience and performance was good (Pearson correlation = 0.76). There were significant differences between the groups for all...

  2. Reliability and performance evaluation of stainless and mild steel ...

    African Journals Online (AJOL)

    Reliability and performance of stainless and mild steel products in methanolic and aqueous sodium chloride media have been investigated. Weight-loss and pre-exposure methods were used. There was a higher rate of weight-loss of mild steels and stainless steels in 1% HCl methanolic solution than in aqueous NaCl ...

  3. Performance test of ex-core high temperature and high pressure water loop test equipment (Contract research)

    International Nuclear Information System (INIS)

    Nakano, Hiroko; Uehara, Toshiaki; Takeuchi, Tomoaki; Shibata, Hiroshi; Nakamura, Jinichi; Matsui, Yoshinori; Tsuchiya, Kunihiko

    2016-03-01

    In Japan Atomic Energy Agency, we started research and development so as to monitor the situations in the Nuclear Plant Facilities during a severe accident, such as a radiation-resistant monitoring camera, a radiation-resistant transmission system for conveying the in-core information, and a heat-resistant signal cable. As a part of developments of the heat-resistant signal cable, we prepared ex-core high-temperature and high-pressure water loop test equipment, which can simulate the conditions of BWRs and PWRs, for evaluating reliability and properties of sheath materials of the cable. This equipment consists of autoclave, water conditioning tank, high-pressure metering pump, preheater, heat exchanger and water purification equipment, etc. This report describes the basic design and the performance test results of ex-core high-temperature and high-pressure water loop test equipment. (author)

  4. Thermal performance envelopes for MHTGRs - Reliability by design

    International Nuclear Information System (INIS)

    Etzel, K.T.; Howard, W.W.; Zgliczynski, J.

    1992-01-01

    Thermal performance envelopes are used to specify steady-state design requirements for the systems of the modular high-temperature gas-cooled reactor (MHTGR) to maximize plant performance reliability with optimized design. The thermal performance envelopes are constructed around the expected operating point to account for uncertainties in actual plant as-built parameters and plant operation. The components are then designed to perform successfully at all points within the envelope. As a result, plant reliability is maximized by accounting for component thermal performance variation in the design. The design is optimized by providing a means to determine required margins in a disciplined and visible fashion. This is accomplished by coordinating these requirements with the various system and component designers in the early stages of the design, applying the principles of total quality management. The design is challenged by the more complex requirements associated with a range of operating conditions, but in return, high probability of delivering reliable performance throughout the plant life is ensured

  5. Fleet equipment performance measurement preventive maintenance model : final report.

    Science.gov (United States)

    2014-04-01

    The concept of preventive maintenance is very important in the effective management and deployment of : vehicle fleets. The Texas Department of Transportation (TxDOT) operates a large fleet of on-road and offroad : equipment. Newer engines and vehicl...

  6. Performance test of nutrient control equipment for hydroponic plants

    Science.gov (United States)

    Rahman, Nurhaidar; Kuala, S. I.; Tribowo, R. I.; Anggara, C. E. W.; Susanti, N. D.

    2017-11-01

    Automatic control equipment has been made for the nutrient content in irrigation water for hydroponic plants. Automatic control equipment with CCT53200E conductivity controller to nutrient content in irrigation water for hydroponic plants, can be used to control the amount of TDS of nutrient solution in the range of TDS numbers that can be set according to the range of TDS requirements for the growth of hydroponically cultivated crops. This equipment can minimize the work time of hydroponic crop cultivators. The equipment measurement range is set between 1260 ppm up to 1610 ppm for spinach plants. Caisim plants were included in this experiment along with spinach plants with a spinach plants TDS range. The average of TDS device is 1450 ppm, while manual (conventional) is 1610 ppm. Nutrient solution in TDS controller has pH 5,5 and temperature 29,2 °C, while manual is pH 5,6 and temperature 31,3 °C. Manually treatment to hydroponic plant crop, yields in an average of 39.6 grams/plant, greater than the yield of spinach plants with TDS control equipment, which is in an average of 24.6 grams / plant. The yield of caisim plants by manual treatment is in an average of 32.3 grams/crop, less than caisim crop yields with TDS control equipment, which is in an average of 49.4 grams/plant.

  7. Life Cycle Management for Equipments in Nuclear Plants Based on Reliability

    International Nuclear Information System (INIS)

    Wang Dalin; Sun Jinlong

    2012-01-01

    Majority of equipments in nuclear power stations are not un-repairable, but repaired after failures or maintained periodically and then returned to running. Along with aging or fatigue causes, duration between failures may be variable such as larger or shorter. Equipments failure occurrences are consistent with non-homogeneous Poisson process (NHPP), in which their failure rates are variable. We chose Weibull process to simplify the actual circumstances to obtain the optimal life cycle management plans approximately. In application we need to estimate parameters of Weibull process with existing data. Before that, trend test is necessary. Total time test (TTT) is an alternative. Trend test can determine whether the failure rate changes along operating time and whether the devices operated under imperfect or minimal repair. Parameters of Weibull process λ, β can be estimated by maximum likelihood estimation method. LCM model is designed to found an optimizing model for those aging equipments under minimal repair or imperfect maintenance with maximum economic or availability as objective function. The purpose is to establish the optimal replacement strategies. Periodical replacement is the most regular choice and so LCM model aims to calculate the optimal replacement periodical duration.

  8. System reliability, performance and trust in adaptable automation.

    Science.gov (United States)

    Chavaillaz, Alain; Wastell, David; Sauer, Jürgen

    2016-01-01

    The present study examined the effects of reduced system reliability on operator performance and automation management in an adaptable automation environment. 39 operators were randomly assigned to one of three experimental groups: low (60%), medium (80%), and high (100%) reliability of automation support. The support system provided five incremental levels of automation which operators could freely select according to their needs. After 3 h of training on a simulated process control task (AutoCAMS) in which the automation worked infallibly, operator performance and automation management were measured during a 2.5-h testing session. Trust and workload were also assessed through questionnaires. Results showed that although reduced system reliability resulted in lower levels of trust towards automation, there were no corresponding differences in the operators' reliance on automation. While operators showed overall a noteworthy ability to cope with automation failure, there were, however, decrements in diagnostic speed and prospective memory with lower reliability. Copyright © 2015. Published by Elsevier Ltd.

  9. Electrical equipment performance under severe accident conditions (BWR/Mark 1 plant analysis): Summary report

    International Nuclear Information System (INIS)

    Bennett, P.R.; Kolaczkowski, A.M.; Medford, G.T.

    1986-09-01

    The purpose of the Performance Evaluation of Electrical Equipment during Severe Accident States Program is to determine the performance of electrical equipment, important to safety, under severe accident conditions. In FY85, a method was devised to identify important electrical equipment and the severe accident environments in which the equipment was likely to fail. This method was used to evaluate the equipment and severe accident environments for Browns Ferry Unit 1, a BWR/Mark I. Following this work, a test plan was written in FY86 to experimentally determine the performance of one selected component to two severe accident environments

  10. Concrete pedestals for high-performance semiconductor production equipment

    Science.gov (United States)

    Vogen, Wayne; Franklin, Craig L.; Morneault, Joseph

    1999-09-01

    Concrete pedestals have many vibration and stiffness characteristics that make them a superior choice for sensitive semiconductor production equipment including scanners, scanning electron microscopes, focused ion beam millers and optical inspection equipment. Among the advantages of concrete pedestals are high inherent damping, monolithic construction that eliminates low stiffness joints common in steep pedestals, ability to reuse and ease of installation. Steel pedestals that have plates attached to the top of the frame are easily excited by acoustic excitation, especially in the range from 50 Hertz to 400 Hertz. Concrete pedestals do not suffer from this phenomenon because of the high mass and damping of the top surface.

  11. Reliability

    OpenAIRE

    Condon, David; Revelle, William

    2017-01-01

    Separating the signal in a test from the irrelevant noise is a challenge for all measurement. Low test reliability limits test validity, attenuates important relationships, and can lead to regression artifacts. Multiple approaches to the assessment and improvement of reliability are discussed. The advantages and disadvantages of several different approaches to reliability are considered. Practical advice on how to assess reliability using open source software is provided.

  12. Performance testing of medical US equipment using US phantom (ATS-539)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Hyung [Daegu Branch, Korea Association of Health Promotion, Daegu (Korea, Republic of); Kwon, Deok Moon [Dept. of Radiology, Daegu Health College, Daegu (Korea, Republic of)

    2014-12-15

    This study is to provide accurate information as medical imaging equipment to check for the presence of body disease US equipment. We investigated the status of medical US equipment performance in Daegu and criteria US phantom (ATS-539) for US equipment performance measurements. The results in this study, 1. US phantom measurement results: The test passed rate were 88.6% and the failed rate were 11.4%. 2. The difference between the group of mean and the pass/failed groups were statistically significant. Focal zone and 4 mm functional resolution in the two items that are not present the passing standard. 3. The difference was statistically significant number of years and used equipment and pass the failed equipment (4.13 vs 7.25 years). We investigated the performance status of US equipment used in the clinical area in Daegu. The basis for the two items are not present this proposed passing standard. Equipment performance was associated with the number of years of using US equipment. It is necessary to maintain the best performance of the equipment phantom measurements for performance testing of US equipment.

  13. Performance testing of medical US equipment using US phantom (ATS-539)

    International Nuclear Information System (INIS)

    Kim, Do Hyung; Kwon, Deok Moon

    2014-01-01

    This study is to provide accurate information as medical imaging equipment to check for the presence of body disease US equipment. We investigated the status of medical US equipment performance in Daegu and criteria US phantom (ATS-539) for US equipment performance measurements. The results in this study, 1. US phantom measurement results: The test passed rate were 88.6% and the failed rate were 11.4%. 2. The difference between the group of mean and the pass/failed groups were statistically significant. Focal zone and 4 mm functional resolution in the two items that are not present the passing standard. 3. The difference was statistically significant number of years and used equipment and pass the failed equipment (4.13 vs 7.25 years). We investigated the performance status of US equipment used in the clinical area in Daegu. The basis for the two items are not present this proposed passing standard. Equipment performance was associated with the number of years of using US equipment. It is necessary to maintain the best performance of the equipment phantom measurements for performance testing of US equipment

  14. Compilation of the calculation elements of the electronic equipments reliability; Recueil des elements de calcul de la fiabilite des equipements electroniques

    Energy Technology Data Exchange (ETDEWEB)

    Lefevre, R.; D' Harcourt, A.; Dupuy, G. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    The aim of this work is to allow the practical execution of the estimated calculation of the electronic devices reliability and to standardize the source and the approach of the calculations while giving a systematic character to their execution mode. The systematic character of the calculations allows a comparison of the reliability of different materials and a rapid control of the calculations validity; at last, it brings out the use conditions of all the components of a set. A reliability calculation made according to the method described here reveals: -components badly used -the relative influence on the reliability of the set, of a component or a components group taking into account of the number, of the characteristics and of the use of these ones. At last, the results of the calculation allows to organize the exploitation (availability) and the maintenance (staff, stock of components) of the materials. The failure rates given in this book are only relating to the components service-life and do not correspond to precocious failures. (authors) [French] L'objet du present recueil est d'une part de permettre l'execution pratique du calcul previsionnel de la fiabilite des equipements electroniques et d'autre part d'uniformiser l'origine et la presentation de calculs en donnant un caractere systematique a leur mode d'execution. Le caractere systematique des calculs permet une comparaison de la fiabilite de differents materiels et un controle rapide de la validite des calculs; enfin il met en relief les conditions d'utilisation de tous les composants d'un ensemble. Un calcul de fiabilite realise selon la methode preconise par ce document permet la mise en evidence: -des composants mal utilises -de l'influence relative sur la fiabilite de l'ensemble, d'un composant ou d'un groupe de composants compte tenu du nombre, des caracteristiques et de l'utilisation de ceux-ci. Enfin, les resultats du

  15. Improving Product Performance Through New Equipment Training (NET) Techniques

    Science.gov (United States)

    2008-12-01

    communication equipment with gloves, acquire targets while wearing helmet and protective eyewear , and stealth movement to contact the enemy and...to be utilized in the literature review. We found that the industry and academic information we retrieved was relevant and transferable to the...chapter summarized industry and academic research relevant to enhancing Marines abilities to better notice and correctly utilize Infantry Combat

  16. Simple, reliable, and nondestructive method for the measurement of vacuum pressure without specialized equipment.

    Science.gov (United States)

    Yuan, Jin-Peng; Ji, Zhong-Hua; Zhao, Yan-Ting; Chang, Xue-Fang; Xiao, Lian-Tuan; Jia, Suo-Tang

    2013-09-01

    We present a simple, reliable, and nondestructive method for the measurement of vacuum pressure in a magneto-optical trap. The vacuum pressure is verified to be proportional to the collision rate constant between cold atoms and the background gas with a coefficient k, which can be calculated by means of the simple ideal gas law. The rate constant for loss due to collisions with all background gases can be derived from the total collision loss rate by a series of loading curves of cold atoms under different trapping laser intensities. The presented method is also applicable for other cold atomic systems and meets the miniaturization requirement of commercial applications.

  17. Photovoltaic Reliability Performance Model v 2.0

    Energy Technology Data Exchange (ETDEWEB)

    2016-12-16

    PV-RPM is intended to address more “real world” situations by coupling a photovoltaic system performance model with a reliability model so that inverters, modules, combiner boxes, etc. can experience failures and be repaired (or left unrepaired). The model can also include other effects, such as module output degradation over time or disruptions such as electrical grid outages. In addition, PV-RPM is a dynamic probabilistic model that can be used to run many realizations (i.e., possible future outcomes) of a system’s performance using probability distributions to represent uncertain parameter inputs.

  18. State-of-art Report on reliability assessment issue of the digital I and C equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Young; Hwang, In Koo; Cha, Kyung Ho; Kwon, Kee Choon; Ham, Chang Shik; Lee, Ki Young; Park, Jong Kyun

    2000-03-01

    As the operational life-time of nuclear power plants being currently developed is increasing with technology improvements, the life-time of instrumentation and control systems is also required to be met to this plant operational period. The electronic devices are usually expected to be available less than for 10 years. Therefore, an appropriate S and PM (surveillance and preventive maintenance) strategy should be established to secure the reliability and availability of the plants. EPRI-URD requires that the mean time between failures caused by any I and C system failure shall be more than 50 operating years. The methodology to access of the mean time between failures of I and C system is included in this report. (author)

  19. Equipment and performance upgrade of compact nuclear simulator

    International Nuclear Information System (INIS)

    Park, Jae Chang; Kwon, Kee Choon; Cha, Hyung Ho; Park, Won Man; Song, Soon Ja; Seh, Kyung Won; Joo, Young Chang

    1998-12-01

    In this project, the techniques to upgrade obsolescent nuclear power plant simulation were developed: the simulation code operated in Macro-VAX II has been transplanted to the HP workstation: commercial equipment PLC was adopted for the interface system: the protection logic was developed in the prototype level: and the display system was strengthened. These techniques can be directly used to upgrade other obsolescent simulators

  20. Equipment and performance upgrade of compact nuclear simulator

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Chang; Kwon, Kee Choon; Cha, Hyung Ho; Park, Won Man; Song, Soon Ja; Seh, Kyung Won; Joo, Young Chang

    1998-12-01

    In this project, the techniques to upgrade obsolescent nuclear power plant simulation were developed: the simulation code operated in Macro-VAX II has been transplanted to the HP workstation: commercial equipment PLC was adopted for the interface system: the protection logic was developed in the prototype level: and the display system was strengthened. These techniques can be directly used to upgrade other obsolescent simulators.

  1. The SACADA database for human reliability and human performance

    International Nuclear Information System (INIS)

    James Chang, Y.; Bley, Dennis; Criscione, Lawrence; Kirwan, Barry; Mosleh, Ali; Madary, Todd; Nowell, Rodney; Richards, Robert; Roth, Emilie M.; Sieben, Scott; Zoulis, Antonios

    2014-01-01

    Lack of appropriate and sufficient human performance data has been identified as a key factor affecting human reliability analysis (HRA) quality especially in the estimation of human error probability (HEP). The Scenario Authoring, Characterization, and Debriefing Application (SACADA) database was developed by the U.S. Nuclear Regulatory Commission (NRC) to address this data need. An agreement between NRC and the South Texas Project Nuclear Operating Company (STPNOC) was established to support the SACADA development with aims to make the SACADA tool suitable for implementation in the nuclear power plants' operator training program to collect operator performance information. The collected data would support the STPNOC's operator training program and be shared with the NRC for improving HRA quality. This paper discusses the SACADA data taxonomy, the theoretical foundation, the prospective data to be generated from the SACADA raw data to inform human reliability and human performance, and the considerations on the use of simulator data for HRA. Each SACADA data point consists of two information segments: context and performance results. Context is a characterization of the performance challenges to task success. The performance results are the results of performing the task. The data taxonomy uses a macrocognitive functions model for the framework. At a high level, information is classified according to the macrocognitive functions of detecting the plant abnormality, understanding the abnormality, deciding the response plan, executing the response plan, and team related aspects (i.e., communication, teamwork, and supervision). The data are expected to be useful for analyzing the relations between context, error modes and error causes in human performance

  2. WWER-1000 unit reliability problems from the point of view of the main supplier of technological equipment

    International Nuclear Information System (INIS)

    Bursa, V.; Holousova, M.; Turnik, S.

    1990-01-01

    At Skoda Works in Plzen, data from the period of construction of nuclear power plants are processed on an ICL DRS 300 computer. The database systems DBASE II and DATAFLEX are available for creating reliability information systems. The information system that is being developed for WWER-1000 units is tested at the WWER-440 units of the Dukovany and Mochovce nuclear power plants. Activities in the field of evaluation of structure reliability of WWER-1000 nuclear power plants are aimed at two major goals, viz., developing a methodology for testing the reliability of the whole unit and its subsystems, and performing reliability analysis and calculations of reliability indices of the secondary circuit of a WWER-1000 nuclear power plant. The reason for the latter concern is the fact that in 1984-1986, secondary circuits contributed 46% to failures of Czechoslovak WWER-440 nuclear power plants. According to existing analyses, the time fluctuations of reliability indices obey no rule that could be employed for inferring indices expected in steady-state operating conditions from indices established in the starting stage of operation. (Z.M.). 10 refs

  3. Review on Fuel Loading Process and Performance for Advanced Fuel Handling Equipment

    International Nuclear Information System (INIS)

    Chang, Sang-Gyoon; Lee, Dae-Hee; Kim, Young-Baik; Lee, Deuck-Soo

    2007-01-01

    The fuel loading process and the performance of the advanced fuel handling equipment for OPR 1000 (Optimized Power Plant) are analyzed and evaluated. The fuel handling equipment, which acts critical processes in the refueling outage, has been improved to reduce fuel handling time. The analysis of the fuel loading process can be a useful tool to improve the performance of the fuel handling equipment effectively. Some recommendations for further improvement are provided based on this study

  4. Telehealth language assessments using consumer grade equipment in rural and urban settings: Feasible, reliable and well tolerated.

    Science.gov (United States)

    Sutherland, Rebecca; Trembath, David; Hodge, Antoinette; Drevensek, Suzi; Lee, Sabrena; Silove, Natalie; Roberts, Jacqueline

    2017-01-01

    Introduction Telehealth can be an effective way to provide speech pathology intervention to children with speech and language impairments. However, the provision of reliable and feasible standardised language assessments via telehealth to establish children's needs for intervention and to monitor progress has not yet been well established. Further, there is limited information about children's reactions to telehealth. This study aimed to examine the reliability and feasibility of conducting standardised language assessment with school-aged children with known or suspected language impairment via a telehealth application using consumer grade computer equipment within a public school setting. Method Twenty-three children (aged 8-12 years) participated. Each child was assessed using a standardised language assessment comprising six subtests. Two subtests were administered by a speech pathologist face-to-face (local clinician) and four subtests were administered via telehealth. All subtests were completed within a single visit to the clinic service, with a break between the face to face and telehealth sessions. The face-to-face clinician completed behaviour observation checklists in the telehealth and face to face conditions and provided feedback on the audio and video quality of the application from the child's point of view. Parent feedback about their child's experience was elicited via survey. Results There was strong inter-rater reliability in the telehealth and face-to-face conditions (correlation coefficients ranged from r = 0.96-1.0 across the subtests) and good agreement on all measures. Similar levels of attention, distractibility and anxiety were observed in the two conditions. Clinicians rated only one session of 23 as having poor audio quality and no sessions were rated as having poor visual quality. Parent and child reactions to the use of telehealth were largely positive and supportive of using telehealth to assess rural children. Discussion The

  5. Human Reliability Analysis for In-Tank Precipitation Alignment and Startup of Emergency Purge Ventilation Equipment. Revision 4

    International Nuclear Information System (INIS)

    Shapiro, B.J.; Britt, T.E.

    1995-06-01

    This report documents the methodology used for calculating the human error probability for establishing air based ventilation using emergency purge ventilation equipment on In-Tank Precipitation (ITP) processing tanks 48 and 49 after a failure of the nitrogen purge system following a seismic event. The analyses were performed according to THERP (Technique for Human Error Rate Prediction) as describes in NUREG/CR-1278-F

  6. Reliability performance testing of totally encapsulating chemical protective suits

    International Nuclear Information System (INIS)

    Johnson, J.S.; Swearengen, P.M.

    1991-01-01

    The need to assure a high degree of reliability for totally encapsulating chemical protective (TECP) suits has been recognized by Lawrence Livermore National Laboratory's (LLNL) Hazards Control Department for some time. The following four tests were proposed as necessary to provide complete evaluation of TECP suit performance: 1. Quantitative leak test (ASTM draft), 2. Worst-case chemical exposure test (conceptual), 3. Pressure leak-rate test (complete, ASTM F1057-87), and 4. Chemical leak-rate test (ASTM draft). This paper reports on these tests which should be applied to measuring TECP suit performance in two stages: design qualification tests and field use tests. Test 1, 2, and 3 are used as design qualification tests, and tests 3 and 4 are used as field use tests

  7. Managing wind turbine reliability and maintenance via performance-based contract

    DEFF Research Database (Denmark)

    Jin, Tongdan; Ding, Yi; Guo, Huairui

    2012-01-01

    between system cost, reliability and spare parts stocking. This analytical insight into the system performance allows the turbine manufacturer to optimize design, production, and after-sales services. The study aims to create a theoretical basis to facilitate the transition of the maintenance paradigm......Performance-based contracting (PBC) is reshaping the acquisition, operation, and maintenance of capital equipment. Under the PBC scheme, we propose a holistic approach for lowering the cost of wind turbine ownership while meeting the availability requirement. Our effects are focused on integrated...... firms who design and market wind turbines, and also provide maintenance and repair service. PBC differs from conventional service contracts in that the wind farmers compensate the service provider for the system performance, not the spare parts and repair labor. We explore the analytical relationship...

  8. Improving motor reliability in nuclear power plants: Volume 1, Performance evaluation and maintenance practices

    International Nuclear Information System (INIS)

    Subudhi, M.; Gunther, W.E.; Taylor, J.H.; Sugarman, A.C.; Sheets, M.W.

    1987-11-01

    This report constitutes the first of the three volumes under this NUREG. The report presents recommendations for developing a cost-effective program for performance evaluation and maintenance of electric motors in nuclear power plants. These recommendations are based on current industry practices, available techniques for monitoring degradation in motor components, manufacturer's recommendations, operating experience, and results from two laboratory tests on aged motors. Two laboratory test reports on a small and a large motor are presented in separate volumes of this NUREG. These provide the basis for the various functional indicators recommended for maintenance programs in this report. The overall preventive maintenance program is separated into two broad areas of activity aimed at mitigating the potential effects of equipment aging: Performance Evaluation and Equipment Maintenance. The latter involves actually maintaining the condition of the equipment while the former involves those activities undertaken to monitor degradation due to aging. These monitoring methods are further categorized into periodic testing, surveillance testing, continuous monitoring and inspections. This study focuses on the methods and procedures for performing the above activities to maintain the motors operationally ready in a nuclear facility. This includes an assessment of various functional indicators to determine their suitability for trending to monitor motor component condition. The intrusiveness of test methods and the present state-of-the-art for using the test equipment in a plant environment are discussed. In conclusion, implementation of the information provided in this report, will improve motor reliability in nuclear power plants. The study indicates the kinds of tests to conduct, how and when to conduct them, and to which motors the tests should be applied. 44 refs., 12 figs., 13 tabs

  9. Performance and equipments upgrade of compact nuclear simulator

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Chang; Kwon, Kee Choon; Sim, Bong Shick; Kim, Jung Taek; Lee, Dong Young; Kim, Chang Hwoi; Park, Won Man; Song, Soon Ja; Yoo, Soon Duk; Yang, Kwang Nam

    1997-12-01

    The compact nuclear simulator (CNS) is installed in the Korea Atomic Energy Research Institute (KAERI) Nuclear Training Center in 1988. The CNS has been used for training of non-operator personnel such as NSSS design engineers, maintenance personnel, inspectors of regulatory body, etc. and for test facility of fuzzy control algorithm. The CNS was manufactured by KAERI and Studsvik (now Eurosim) joint project. The CNS mathematical modeling modeled a three loop Westinghouse Pressurizer Water Reactor (PWR), 993 MWe, mostly referred to as the Kori Unit 3 and 4 in Korea. But the main computer (Micro VAX II), a interface card between main computer and operator panel, and a graphic interface system are faced with frequent troubles by obsolescence and lack of spare parts. According to the above reasons, the CNS hardware should be replaced by state of the art equipment. It is planned to replace the main computer with HP workstation, a dedicated interface card with a PLC-based interface system, and a graphic interface system with an X-terminal based full graphics system. The software for a instructor console also will be modified text-based to Motif-based user interface. The Motif-based user interface provides more efficient and easy operation in a instructor console also will be modified text-based to Motif-based user interface. The Motif-based user interface provides more efficient and easy operation in a instructor console. (author). 124 refs., 2 tabs., 24 figs

  10. Specific issues for seismic performance of power plant equipment

    Energy Technology Data Exchange (ETDEWEB)

    Nawrotzki, Peter [GERB Vibration Control Systems, Berlin (Germany)

    2010-01-15

    Power plant machinery can be dynamically decoupled from the substructure by the effective use of helical steel springs and viscous dampers. Turbine foundations, coal mills, boiler feed pumps and other machine foundations benefit from this type of elastic support systems to mitigate the transmission of operational vibration. The application of these devices may also be used to protect against earthquakes and other catastrophic events, i.e. airplane crash, of particular importance in nuclear facilities. This article illustrates basic principles of elastic support systems and applications on power plant equipment and buildings in medium and high seismic areas. Spring damper combinations with special stiffness properties are used to reduce seismic acceleration levels of turbine components and other safety or non-safety related structures. For turbine buildings, the integration of the turbine sub-structure into the machine building can further reduce stress levels in all structural members. The application of this seismic protection strategy for a spent fuel storage tank in a high seismic area is also discussed. Safety in nuclear facilities is of particular importance and recent seismic events and the resulting damage in these facilities again brings up the discussion. One of the latest events is the 2007 Chuetsu earthquake in Japan. The resulting damage in the Kashiwazaki Kariwa Nuclear Power Plant can be found in several reports, e.g. in Yamashita. (orig.)

  11. Equipment reliability and life cycle optimization of a nuclear plant feedwater heater

    International Nuclear Information System (INIS)

    Thomas, Daniel; Coakley, Michael; Catapano, Michael; Svensson, Eric

    2006-01-01

    Many papers published over the last 25 years have strongly emphasized the need for an ongoing program of inspection and testing with subsequent failure cause analysis of feedwater heaters. Plants must be run more competitively; therefore, Utilities must lower operation and maintenance costs, while optimizing overall plant efficiency and capacity factor. One recognized area that needs to be addressed in accomplishing this goal is the heat cycle. This paper specifically deals with the feedwater heating system. Utility engineers must monitor feedwater heater performance in order to recognize degradation, identify and mitigate failure mechanisms, and prevent in-service failures thereby optimizing availability. Periodic tube plugging without complete analysis of the degraded/failed areas resolves the immediate need for return to service; however, heater life will not be optimized. This paper illustrates a complete life cycle management inspection, testing, and maintenance program implemented at Peach Bottom Atomic Power Station (PBAPS). Concerns that tubes may have been too conservatively plugged due to insufficient data and lack of root cause analysis, justified a program that included: - Removal of previously installed plugs; - Video-probe inspection of failed areas; - Extraction of tube samples for further analysis; - Eddy current testing of selected tubes; - Evaluation of the condition of 'insurance' plugged tubes for return to service; - Hydrostatic testing of selected individual tubes; - Final repair plan based on the results of the above program. This paper concludes that no single method of inspection or testing should solely be relied upon in establishing: - The extent of actual degraded conditions; - The mechanism(s) of failure; - The details of repair to be implemented. Evaluating all data affords the best chance in arresting problems and optimizing feedwater heater life. Problem heaters should be continuously monitored and inspected over time until the facts

  12. Reliability of performance velocity for jump squats under feedback and nonfeedback conditions.

    Science.gov (United States)

    Randell, Aaron D; Cronin, John B; Keogh, Justin Wl; Gill, Nicholas D; Pedersen, Murray C

    2011-12-01

    Randell, AD, Cronin, JB, Keogh, JWL, Gill, ND, and Pedersen, MC. Reliability of performance velocity for jump squats under feedback and nonfeedback conditions. J Strength Cond Res 25(12): 3514-3518, 2011-Advancements in the monitoring of kinematic and kinetic variables during resistance training have resulted in the ability to continuously monitor performance and provide feedback during training. If equipment and software can provide reliable instantaneous feedback related to the variable of interest during training, it is thought that this may result in goal-oriented movement tasks that increase the likelihood of transference to on-field performance or at the very least improve the mechanical variable of interest. The purpose of this study was to determine the reliability of performance velocity for jump squats under feedback and nonfeedback conditions over 3 consecutive training sessions. Twenty subjects were randomly allocated to a feedback or nonfeedback group, and each group performed a total of 3 "jump squat" training sessions with the velocity of each repetition measured using a linear position transducer. There was less change in mean velocities between sessions 1-2 and sessions 2-3 (0.07 and 0.02 vs. 0.13 and -0.04 m·s), less random variation (TE = 0.06 and 0.06 vs. 0.10 and 0.07 m·s) and greater consistency (intraclass correlation coefficient = 0.83 and 0.87 vs. 0.53 and 0.74) between sessions for the feedback condition as compared to the nonfeedback condition. It was concluded that there is approximately a 50-50 probability that the provision of feedback was beneficial to the performance in the squat jump over multiple sessions. It is suggested that this has the potential for increasing transference to on-field performance or at the very least improving the mechanical variable of interest.

  13. Performance of indigenous resistance welding equipment for PHWR fuel fabrication in NFC

    International Nuclear Information System (INIS)

    Hemantha Rao, G.V.S.; Jayaraj, R.N.; Prakash, M.S.; Gupta, U.C.; Ganguly, C.

    1999-01-01

    Indigenisation of critical equipment for manufacturing of PHWR fuel and automation in the production line have been the main thrust in NFC in recent years. As part of this endeavour, resistance welding equipment for end plug welding of Zircaloy-4 clad Uranium Oxide fuel pin and end plates of 19-element fuel bundles have been developed. The paper discusses the equipment design features, critical operating parameters and performance of these indigenous welding machines. (author)

  14. SU-F-E-01: Pitfalls: Reliability and Performance of Diagnostic X-Sources

    Energy Technology Data Exchange (ETDEWEB)

    Behling, R [Philips Medical Systems DMC GmbHHamburg (United States)

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. The author is employee of Royal Philips.

  15. SU-F-E-01: Pitfalls: Reliability and Performance of Diagnostic X-Sources

    International Nuclear Information System (INIS)

    Behling, R

    2016-01-01

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. The author is employee of Royal Philips

  16. Assessment of the performance of containment and surveillance equipment part 1: methodology

    International Nuclear Information System (INIS)

    Rezniczek, A.; Richter, B.

    2009-01-01

    Equipment performance aims at the creation of relevant data. As Containment and Surveillance (C/S) is playing an ever increasing role in safeguards systems, the issue of how to assess the performance of C/S equipment is being addressed by the ESARDA Working Group on C/S. The issue is important not only for the development of appropriate safeguards approaches but also for the review of existing approaches with regard to the implementation of the Additional Protocol (A P) and Integrated Safeguards. It is expected that the selection process of appropriate equipment, especially for unattended operation, is facilitated by the availability of methods to determine the performance of such equipment. Apart from EURATOM, the users of assessment methodologies would be the International Atomic Energy Agency (IAEA), plant operators, and instrument developers. The paper describes a non-quantitative performance assessment methodology. A structured procedure is outlined that allows assessing the suitability of different C/S instrumentation to comply with the objectives of its application. The principle to determine the performance of C/S equipment is to define, based on safeguards requirements, a task profile and to check the performance profile against the task profile. The performance profile of C/S equipment can be derived from the functional specifications and design basis tolerances provided by the equipment manufacturers.

  17. Considerations concerning the reliability of reactor safety equipment; Considerations sur la fiabilite des ensembles de securite de reacteurs

    Energy Technology Data Exchange (ETDEWEB)

    Furet, J; Guyot, Ch [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    A review is made of the circumstances which favor a good collection of maintenance data at the C.E.A. The large amount of data to be treated has made necessary the use of a computer for analyzing automatically the results collected. Here, only particular aspects of the reliability from the point of view of the electronics used for nuclear reactor control will be dealt with: sale and unsafe failures; probability of survival (in the case of reactor safety); availability. The general diagrams of the safety assemblies which have been drawn up for two types of reactor (power reactor and low power experimental reactor) are given. Results are presented of reliability analysis which could be applied to the use of functional modular elements, developed industrially in France. Improvement of this reliability appears to be fairly limited by an increase in the redundancy; on the other hand it is shown how it may be very markedly improved by the use of automatic tests with different frequencies for detecting unsafe failures rates of measurements for the sub-assemblies and for the logic sub-assemblies. Finally examples are given to show the incidence of the complexity and of the use of different technologies in reactor safety equipment on the reliability. (authors) [French] On rappelle les circonstances qui favorisent au C.E.A. la collecte d'une information valable des resultats de la maintenance. L'importance des donnees a traiter a rendu necessaire l'utilisation d'une calculatrice poux l'analyse automatique des resultats recueillis. On se limitera ici aux aspects particuliers de la fiabilite du point de vue de l'electronique pour le controle et la commande de reacteurs nucleaires: pannes sures et pannes non sures; probabilite de survie dans le cas de la securite des reacteurs; facteur de disponibilite. Les schemas de principe des ensembles de securite definis pour deux types de reacteurs (reacteur de puissance et reacteur experimental de faible puissance) sont indiques. On

  18. Root cause analysis underscores the importance of understanding, addressing, and communicating cold chain equipment failures to improve equipment performance.

    Science.gov (United States)

    Lennon, Pat; Atuhaire, Brian; Yavari, Shahrzad; Sampath, Vidya; Mvundura, Mercy; Ramanathan, Nithya; Robertson, Joanie

    2017-04-19

    Vaccine cold chain equipment (CCE) in developing countries is often exposed to harsh environmental conditions, such as extreme temperatures and humidity, and is subject to many additional challenges, including intermittent power supply, insufficient maintenance capacity, and a scarcity of replacement parts. Together, these challenges lead to high failure rates for refrigerators, potentially damaging vaccines and adversely affecting immunization coverage. Providing a sustainable solution for improving CCE performance requires an understanding of the root causes of failure. Project teams conducted small-scale studies to determine the root causes of CCE failure in selected locations in Uganda and Mozambique. The evaluations covered 59 failed refrigerators and freezers in Uganda and 27 refrigerators in Mozambique. In Uganda, the vast majority of failures were due to a cooling unit fault in one widely used refrigerator model. In Mozambique, 11 of the 27 problems were attributable to solar refrigerators with batteries that were unable to hold a charge, and another eight problems were associated with a need to adjust thermostat settings. The studies showed that tracking and evaluation of equipment performance and failure can yield important, actionable information for a range of stakeholders, including local CCE technicians, the ministry of health, equipment manufacturers, and international partners such as the United Nations Children's Fund, World Health Organization, and Gavi, the Vaccine Alliance. Collaborative efforts to systematically collect and communicate data on CCE performance and causes of failure will help to improve the efficiency and reach of immunization programs in low- and middle-income countries. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  19. 40 CFR 63.2994 - How do I verify the performance of monitoring equipment?

    Science.gov (United States)

    2010-07-01

    ... equipment? (a) Before conducting the performance test, you must take the steps listed in paragraphs (a)(1) and (2) of this section: (1) Install and calibrate all process equipment, control devices, and... evaluation results. (b) If you use a thermal oxidizer, the temperature monitoring device must meet the...

  20. Performance Evaluation and Suggestion of Upgraded Fuel Handling Equipment for Operating OPR1000

    International Nuclear Information System (INIS)

    Chang, Sang Gyoon; Hwang, Jeung Ki; Choi, Taek Sang; Na, Eun Seok; Lee, Myung Lyul; Baek, Seung Jin; Kim, Man Su; Kunik, Jack

    2011-01-01

    The purpose of this study is to evaluate the performance of upgraded FHE (Fuel Handling Equipment) for operating OPR 1000 (Optimized Power Reactor) by using data measured during the fuel reloading, and make some suggestions on enhancing the performance of the FHE. The fuel handling equipment, which serves critical processes in the refueling outage, has been upgraded to increase and improve the operational availability of the plant. The evaluation and suggestion of this study can be a beneficial tool related to the performance of the fuel handling equipment

  1. Reliability and validity of the Performance Recorder 1 for measuring isometric knee flexor and extensor strength.

    Science.gov (United States)

    Neil, Sarah E; Myring, Alec; Peeters, Mon Jef; Pirie, Ian; Jacobs, Rachel; Hunt, Michael A; Garland, S Jayne; Campbell, Kristin L

    2013-11-01

    Muscular strength is a key parameter of rehabilitation programs and a strong predictor of functional capacity. Traditional methods to measure strength, such as manual muscle testing (MMT) and hand-held dynamometry (HHD), are limited by the strength and experience of the tester. The Performance Recorder 1 (PR1) is a strength assessment tool attached to resistance training equipment and may be a time- and cost-effective tool to measure strength in clinical practice that overcomes some limitations of MMT and HHD. However, reliability and validity of the PR1 have not been reported. Test-retest and inter-rater reliability was assessed using the PR1 in healthy adults (n  =  15) during isometric knee flexion and extension. Criterion-related validity was assessed through comparison of values obtained from the PR1 and Biodex® isokinetic dynamometer. Test-retest reliability was excellent for peak knee flexion (intra-class correlation coefficient [ICC] of 0.96, 95% CI: 0.85, 0.99) and knee extension (ICC  =  0.96, 95% CI: 0.87, 0.99). Inter-rater reliability was also excellent for peak knee flexion (ICC  =  0.95, 95% CI: 0.85, 0.99) and peak knee extension (ICC  =  0.97, 95% CI: 0.91, 0.99). Validity was moderate for peak knee flexion (ICC  =  0.75, 95% CI: 0.38, 0.92) but poor for peak knee extension (ICC  =  0.37, 95% CI: 0, 0.73). The PR1 provides a reliable measure of isometric knee flexor and extensor strength in healthy adults that could be used in the clinical setting, but absolute values may not be comparable to strength assessment by gold-standard measures.

  2. DEVELOPING OF INDIVIDUAL INSTRUMENT PERFORMANCE ANXIETY SCALE: VALIDITY - RELIABILITY STUDY

    Directory of Open Access Journals (Sweden)

    Esra DALKIRAN

    2014-07-01

    Full Text Available The purpose of this study is to develop a scale unique to our culture, concerning  individual instrument performance anxiety of the students  who are getting instrument training  in the Department of Music Education. In the study, the descriptive research model is used and qualitative research techniques are utilized. The study population consists of the students attending the 23 universities which has Music Education Department. The sample of the study consists of 438 girls and 312 boys, totally 750 students  who are studying in the Department of Music Education of randomly selected 10 universities. As a result of the explanatory and confirmatory factor analyses that were performed, a one-dimensional structure consisting of 14 items was obtained. Also, t-scores and  the coefficient scores of total item correlation concerning the distinguishing power of the items, the difference in the scores of the set of lower and upper 27% was calculated, and it was observed that the items are distinguishing as a result of both analyses. Of the scale, Cronbach's alpha coefficient of internal consistency was calculated as .94, and test-retest reliability coefficient was calculated as .93. As a result, a valid and reliable assessment and evaluation instrument that measures the exam performance anxiety of the students studying in the Department of Music Education, has been developed.Extended AbstractsIntroductionAnxiety is a universal phenomenon which people experience once or a few times during lives. It was accepted as concern for the future or as an unpleasant emotional experience regarding probable hitches of the events (Di Tomasso & Gosch, 2002.In general, the occasions on which negative feelings are experienced cause anxiety to arise (Baltaş and Baltaş, 2000. People also feel anxious in dangerous situations. Anxiety may lead a person to be creative, while it may have hindering characteristics. Anxiety is that an individual considers him

  3. Track 2- major components reliability and materials issues. Some performance indicators of PWR steam generators

    International Nuclear Information System (INIS)

    Milivojevic, S.; Spasojevic, D.; Riznic, J.

    2001-01-01

    The monitoring of operational performance is a crucial aspect of the management of equipment operation and maintenance in many industries, including nuclear and thermal power plants. Monitoring involves the collection and analysis of data on the operation. In these paper an analysis was made of steam generators in operation, i.e., their malfunctions during the plant life cycle with the aim of studying the characteristics of failure rate and repair rate. These values are necessary parameters if we are to determine the reliability and availability of the steam generator as a basis for the analysis of its effect on the safety and efficiency of the nuclear power plant. We analyzed IAEA available data for period from 1971 to 1998. Each steam generator was monitored individually during plants' lifetime. The data on steam generator failures were presented in uniform format, allowing the consistency in failure classification and data reporting. Operational presence of the analyzed steam generators is given for each calendar year and each lifetime year: the failure rate l and repair rate m with associated boundaries are calculated. The general trends in calendar years performance indicators (μ) of steam generators is investigated. The distributions of lifetime l and m are formed, as a complement to the analysis of calendar years performance indicators. With aspect of steam generators influence on reliability and availability of nuclear power plants, the empirical probability distribution for failure rates and repair rates are also constructed. (author)

  4. The use of commercial microwave dissolution equipment for the fast and reliable dissolution of high-fired POX and MOX samples

    International Nuclear Information System (INIS)

    Tushingham, J.; McInnes, C.; Firkin, S.

    1998-09-01

    The use of commercially available microwave dissolution equipment for the fast and reliable dissolution of high-fired plutonium dioxide (POX) and mixed oxide (MOX) samples has been evaluated for application to Safeguards Analysis. Under the auspices of the UK R and D Support Programme to the IAEA, equipment has been purchased and tested for the high-pressure microwave dissolution of POX samples fired to 1250 deg. C and MOX samples fired to 1600 deg. C, in concentrated nitric acid and hydrofluoric acid mixture. Considerable problems were encountered during development of procedures for microwave dissolution, resulting largely from sudden changes in pressure within dissolution vessels, which resulted in actuation of safety interlocks designed to prevent overpressurisation. These difficulties were alleviated by controlling the microwave power to reduce the reaction temperature and pressure, and also by introducing additional safety valves into the digestion vessels. Using microwave digestion, dissolution times for high fired POX and MOX samples were substantially reduced. Samples which required ca. 10 hours to dissolve by conventional means could be dissolved in ca. 80 minutes by microwave digestion. Whilst a similar performance in terms of plutonium recovery was achieved for some materials by microwave and conventional dissolution, for other materials microwave dissolution gave higher plutonium recoveries but with poorer precision. This suggests the possible presence of some plutonium oxide within high-fired materials which is more difficult to dissolve than the bulk, and which is perhaps dissolved to an additional but variable degree by the current microwave dissolution procedure. Microwave dissolution has been demonstrated to increase the speed of dissolution of high-fired POX and MOX materials, compared with conventional dissolution. However, the technique has not yet proved satisfactory for the complete dissolution of all high-fired materials tested because of

  5. Development of KSC program for investigating and generating field failure rates. Volume 2: Recommended format for reliability handbook for ground support equipment

    Science.gov (United States)

    Bloomquist, C. E.; Kallmeyer, R. H.

    1972-01-01

    Field failure rates and confidence factors are presented for 88 identifiable components of the ground support equipment at the John F. Kennedy Space Center. For most of these, supplementary information regarding failure mode and cause is tabulated. Complete reliability assessments are included for three systems, eight subsystems, and nine generic piece-part classifications. Procedures for updating or augmenting the reliability results presented in this handbook are also included.

  6. Reliability prediction for the vehicles equipped with advanced driver assistance systems (ADAS and passive safety systems (PSS

    Directory of Open Access Journals (Sweden)

    Balbir S. Dhillon

    2012-10-01

    Full Text Available The human error has been reported as a major root cause in road accidents in today’s world. The human as a driver in road vehicles composed of human, mechanical and electrical components is constantly exposed to changing surroundings (e.g., road conditions, environmentwhich deteriorate the driver’s capacities leading to a potential accident. The auto industries and transportation authorities have realized that similar to other complex and safety sensitive transportation systems, the road vehicles need to rely on both advanced technologies (i.e., Advanced Driver Assistance Systems (ADAS and Passive Safety Systems (PSS (e.g.,, seatbelts, airbags in order to mitigate the risk of accidents and casualties. In this study, the advantages and disadvantages of ADAS as active safety systems as well as passive safety systems in road vehicles have been discussed. Also, this study proposes models that analyze the interactions between human as a driver and ADAS Warning and Crash Avoidance Systems and PSS in the design of vehicles. Thereafter, the mathematical models have been developed to make reliability prediction at any given time on the road transportation for vehicles equipped with ADAS and PSS. Finally, the implications of this study in the improvement of vehicle designs and prevention of casualties are discussed.

  7. TH-F-209-01: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    International Nuclear Information System (INIS)

    Behling, R.

    2016-01-01

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  8. TH-F-209-00: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    International Nuclear Information System (INIS)

    2016-01-01

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  9. TH-F-209-01: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Behling, R. [Philips Medical Systems DMC GmbH (United States)

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  10. TH-F-209-00: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  11. Assessment of the performance of containment and surveillance equipment part 2: trial application

    International Nuclear Information System (INIS)

    Rezniczek, A.; Richter, B.; Jussofie, A.

    2009-01-01

    The adopted methodological approach for assessing the performance of Containment and Surveillance (C/S) equipment resulted from an account of work performed for and in cooperation with the ESARDA Working Group on C/S. It was applied on a trial basis to a dry storage facility for spent nuclear fuel and consisted of the following steps: (1) Acquisition and analysis of design information and operational characteristics of the facility under consideration, (2) assumptions on diversion and misuse scenarios, (3) assumptions on safeguards approach and definition of safeguards requirements, (4) compilation and characterisation of candidate C/S equipment, (5) performance assessment of C/S equipment. The candidate equipment taken into account was routinely used by the IAEA: DCM14-type camera, Type E capand- wire seal, COBRA fibre optic seal, and VACOSS electronic seal. Four applications were considered: camera mounted in the reception area, seal on secondary lid of transport and storage cask, seal on protective lid, and seal on group of casks. For these applications, requirements were defined and requirement levels were attributed. The assignment of performance levels was carried out by using the technical specifications and design basis tolerances provided by the equipment manufacturers. The results were entered into four performance assessment tables. Although the assessment methodology was not yet fully developed, its trial application yielded promising results with regard to the selection of appropriate C/S equipment.

  12. Understanding organic photovoltaic cells: Electrode, nanostructure, reliability, and performance

    Science.gov (United States)

    Kim, Myung-Su

    My Ph.D. research has focused on alternative renewable energy using organic semiconductors. During my study, first, I have established reliable characterization methods of organic photovoltaic devices. More specifically, less than 5% variation of power conversion efficiency of fabricated organic blend photovoltaic cells (OBPC) was achieved after optimization. The reproducibility of organic photovoltaic cell performance is one of the essential issues that must be clarified before beginning serious investigations of the application of creative and challenging ideas. Second, the relationships between fill factor (FF) and process variables have been demonstrated with series and shunt resistance, and this provided a chance to understand the electrical device behavior. In the blend layer, series resistance (Rs) and shunt resistance (Rsh) were varied by controlling the morphology of the blend layer, the regioregularity of the conjugated polymer, and the thickness of the blend layer. At the interface between the cathode including PEDOT:PSS and the blend layer, cathode conductivity was controlled by varying the structure of the cathode or adding an additive. Third, we thoroughly examined possible characterization mistakes in OPVC. One significant characterization mistake is observed when the crossbar electrode geometry of OPVC using PEDOT:PSS was fabricated and characterized with illumination which is larger than the actual device area. The hypothesis to explain this overestimation was excess photo-current generated from the cell region outside the overlapped electrode area, where PEDOT:PSS plays as anode and this was clearly supported with investigations. Finally, I incorporated a creative idea, which enhances the exciton dissociation efficiency by increasing the interface area between donor and acceptor to improve the power conversion efficiency of organic photovoltaic cells. To achieve this, nanoimprint lithography was applied for interface area increase. To clarify the

  13. Research performed at the ET-RR-1 reactor using the neutron scattering equipment

    International Nuclear Information System (INIS)

    Adib, M.; Maayouf, R.M.A.; Abdel-Kawy, A.

    1990-02-01

    This report represents the results of studies and measurements, performed at the ET-RR-1 reactor, using the neutron scattering equipment supplied by the IAEA according to the technical assistance project EGY/1/11/10. The results of these studies, starting in 1980 and continuing to date, are discussed; the use of the equipment, both as a neutron monochromator and fixed scattering angle spectrometer, is also assessed. (author). 19 refs, 17 figs

  14. Reliable and valid assessment of performance in thoracoscopy

    DEFF Research Database (Denmark)

    Konge, Lars; Lehnert, Per; Hansen, Henrik Jessen

    2012-01-01

    BACKGROUND: As we move toward competency-based education in medicine, we have lagged in developing competency-based evaluation methods. In the era of minimally invasive surgery, there is a need for a reliable and valid tool dedicated to measure competence in video-assisted thoracoscopic surgery....... The purpose of this study is to create such an assessment tool, and to explore its reliability and validity. METHODS: An expert group of physicians created an assessment tool consisting of 10 items rated on a five-point rating scale. The following factors were included: economy and confidence of movement...

  15. Maintenance personnel performance simulation (MAPPS): a model for predicting maintenance performance reliability in nuclear power plants

    International Nuclear Information System (INIS)

    Knee, H.E.; Krois, P.A.; Haas, P.M.; Siegel, A.I.; Ryan, T.G.

    1983-01-01

    The NRC has developed a structured, quantitative, predictive methodology in the form of a computerized simulation model for assessing maintainer task performance. Objective of the overall program is to develop, validate, and disseminate a practical, useful, and acceptable methodology for the quantitative assessment of NPP maintenance personnel reliability. The program was organized into four phases: (1) scoping study, (2) model development, (3) model evaluation, and (4) model dissemination. The program is currently nearing completion of Phase 2 - Model Development

  16. Reliability of magnetic particle inspection performed through coatings: Final report

    International Nuclear Information System (INIS)

    1988-07-01

    The magnetic particle examination (MT) technique can reliably examine containment welds without removing their protective coatings. This study has investigated a variety of MT methods used in the oil and gas industry for their suitability for nuclear plant applications. 102 figs

  17. Performance of nuclear power plants and analysis of some factors affecting their operational reliability and economy

    International Nuclear Information System (INIS)

    Kozak, M.; Havel, S.

    1989-09-01

    In Czechoslovakia, there are eight WWER 440 type reactors in operation at present. Since their introduction into operation, nuclear power plants in Czechoslovakia have exhibited high reliability. In the paper, total parameters of reliability with an analysis of causes affecting negatively their annual utilization are presented. Existence of a computerized information system for acquisition, recording and evaluation of reliability-significant data from operation and its feedback to designers and manufacturers of nuclear power plant equipment and components is a basic requirement of a systematic assurance of the needed level of nuclear power plant reliability. The information system is used simultaneously also for realistic evaluation of aging of equipment and systems. Analysis of the state of equipment is important mainly in the final stage of the NPP during consideration of further extension of its service life. Environmental effects of the Czechoslovak NPPs are very low (favourable). It follows from comparison of annual dose equivalents of the Czechoslovak NPPs operational personnel with the foreign NPPs that the values recorded in Czechoslovakia belong to the lowest ones. In conclusion, some ways of assurance of operational safety and reliability of the Czechoslovak nuclear power plants including the role of the State regulatory body are briefly discussed. (author). 3 tabs

  18. Extension and update of the reliability data for fire protection equipment in German light water reactors; Ergaenzung und Aktualisierung von Zuverlaessigkeitskenngroessen fuer Brandschutzeinrichtungen in deutschen Leichtwasserreaktoren

    Energy Technology Data Exchange (ETDEWEB)

    Forell, Burkhard; Einarsson, Svante

    2016-12-15

    Within the BMUB project 3610R01370 ''Extension and update of reliability data for fire protection equipment in German light water reactors'' plant-specific as well as generic failure rates for the technical reliability of active fire protection features in German nuclear power plants have been calculated. Based on results of previous projects, in this project observation times of components were updated and extended and additional components and functions were assessed. Now, the data evaluated results from a total of six German reference plants with seven reactor units.

  19. Improving Stochastic Communication Network Performance: Reliability vs. Throughput

    Science.gov (United States)

    1991-12-01

    increased to one. 2) arc survivabil.. ities will be increased in increments of one tenths. and 3) the costs to increase- arc si’rvivabilities were equal and...This reliability value is leni used to maximize the associated expected flow. For Net work A. a bIdget of (8)() pro(duces a tradcoff point at (.58.37...Network B for a buidgel of 2000 which allows a nel \\\\ork relial)ilitv of one to be achieved and a bidget of 1200 which allows for ;, maximum 57

  20. Human Performance Modeling for Dynamic Human Reliability Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Boring, Ronald Laurids [Idaho National Laboratory; Joe, Jeffrey Clark [Idaho National Laboratory; Mandelli, Diego [Idaho National Laboratory

    2015-08-01

    Part of the U.S. Department of Energy’s (DOE’s) Light Water Reac- tor Sustainability (LWRS) Program, the Risk-Informed Safety Margin Charac- terization (RISMC) Pathway develops approaches to estimating and managing safety margins. RISMC simulations pair deterministic plant physics models with probabilistic risk models. As human interactions are an essential element of plant risk, it is necessary to integrate human actions into the RISMC risk framework. In this paper, we review simulation based and non simulation based human reliability analysis (HRA) methods. This paper summarizes the founda- tional information needed to develop a feasible approach to modeling human in- teractions in RISMC simulations.

  1. A novel mechanical design of broken rope protection device for enhancing the safety performances of overhead manned equipment in coal mine

    Directory of Open Access Journals (Sweden)

    Xiaoguang Zhang

    2015-08-01

    Full Text Available A novel mechanical design of the broken rope protection device is proposed to enhance the safety performances of the overhead manned equipment. According to the operating characteristics and functional requirements of the overhead manned equipment, a three-dimensional mechanical model of the broken rope protection device was redesigned. Based on the known parameters of the mechanical model, the stress and strength of the main components are readjusted using the statics characteristics of finite element analysis. To ensure the reliability of the control system of the broken rope protection device, the process of people’s falling, the response performance of the tension sensor, and the signal extraction of the broken rope are analyzed under different loading and unloading speeds. The working principle of the broken rope protection device is expounded in detail. The experimental results showed that better effect is obtained by the new broken rope protection device, which is characterized by good durability, low investment, and high reliability.

  2. Training Corrective Maintenance Performance on Electronic Equipment with CAI Terminals: I. A Feasibility Study.

    Science.gov (United States)

    Rigney, Joseph W.

    A report is given of a feasibility study in which several possible relationships between student, computer terminal, and electronic equipment were considered. The simplest of these configurations was set up and examined in terms of its feasibility for teaching the performance of fault localization on a Navy transceiver. An instructional program…

  3. Performance Indexing: Assessing the Nonmonetized Returns on Investment in Military Equipment

    Science.gov (United States)

    2016-05-17

    Image designed by Diane Fleischer PERFORMANCE INDEXING: Assessing the NONMONETIZED RETURNS ON INVESTMENT in Military Equipment Ian D...MacLeod and Capt Robert A. Dinwoodie, USMC A prime managerial concern is how to decide which investment alternatives provide the greatest return with...agencies, these methods often fall short because typical governmental investments do not have a monetary return. The processes underpinning governmental

  4. 75 FR 76254 - Official Performance and Procedural Requirements for Grain Weighing Equipment and Related Grain...

    Science.gov (United States)

    2010-12-08

    ... DEPARTMENT OF AGRICULTURE Grain Inspection, Packers and Stockyards Administration 7 CFR Part 802 [Docket GIPSA-2010-FGIS-0012] RIN 0580-AB19 Official Performance and Procedural Requirements for Grain Weighing Equipment and Related Grain Handling Systems AGENCY: Grain Inspection, Packers and Stockyards...

  5. The role of human reliability analysis for enhancing crew performance

    International Nuclear Information System (INIS)

    Hannaman, G.W.; Joksimovich, V.; Worledge, D.H.; Spurgin, A.J.

    1986-01-01

    This paper summarizes some aspects of EPRI-sponsored research undertaken in support of improving the PRA technology. In particular, the consideration of how human actions that impact accident sequences can be analyzed in a systematic way to supplement the type of ergonomic studies normally carried out in support of control room design. The HRA/PRA approach described not only identifies the operator information and interface needs, but also helps to identify issues and areas for additional research. The process includes a link to data collections. Preliminary collections of data and analytical benchmark support the idea that such analytical frameworks and models provide support for ranking the importance of various human reliability issues

  6. Carbohydrate ingestion improves performance of a new reliable test of soccer performance.

    Science.gov (United States)

    Currell, Kevin; Conway, Steve; Jeukendrup, Asker E

    2009-02-01

    The aim of the study was to investigate the reliability of a new test of soccer performance and evaluate the effect of carbohydrate (CHO) on soccer performance. Eleven university footballers were recruited and underwent 3 trials in a randomized order. Two of the trials involved ingesting a placebo beverage, and the other, a 7.5% maltodextrin solution. The protocol comprised a series of ten 6-min exercise blocks on an outdoor Astroturf pitch, separated by the performance of 2 of the 4 soccer-specific tests, making the protocol 90 min in duration. The intensity of the exercise was designed to be similar to the typical activity pattern during soccer match play. Participants performed skill tests of dribbling, agility, heading, and shooting throughout the protocol. The coefficients of variation for dribbling, agility, heading, and shooting were 2.2%, 1.2%, 7.0%, and 2.8%, respectively. The mean combined placebo scores were 42.4 +/- 2.7 s, 43.1 +/- 3.7 s, 210 +/- 34 cm, and 212 +/- 17 points for agility, dribbling, heading, and kicking, respectively. CHO ingestion led to a combined agility time of 41.5 +/- 0.8 s, for dribbling 41.7 +/- 3.5 s, 213 +/- 11 cm for heading, and 220 +/- 5 points for kicking accuracy. There was a significant improvement in performance for dribbling, agility, and shooting (p soccer performance, and ingesting CHO leads to an improvement in soccer performance.

  7. Development of a Test Equipment for Performance Evaluation of Safety Systems

    International Nuclear Information System (INIS)

    Kim, S. J.; Kwon, S. M.; Lee, J. M.; Kim, C. K.; Cho, C. H.; Chun, J. H.; Park, M. K.

    2004-07-01

    The purpose of this study is to develop a test equipment for performance evaluation of safety systems in nuclear power plants. First, we develop an input-output simulator for reactor protection systems, ESF component control systems, and a data acquisition system for these I/O simulators as a hardware for this equipment. Then, we develop a software for human-machine interface system, which is easy-to-use and easy-to-modify. In addition, a simulation tool for a reactor trip switch gear is developed

  8. AIChe equipment testing procedure centrifugal compressors : a guide to performance evaluation and site testing

    CERN Document Server

    AIChE

    2013-01-01

    With its engineer-tested procedures and thorough explanations, Centrifugal Compressors is an essential text for anyone engaged in implementing new technology in equipment design, identifying process problems, and optimizing equipment performance.  This condensed book presents a step by step approach to preparing for, planning, executing, and analyzing tests of centrifugal compressors, with an emphasis on methods that can be conducted on-site and with an acknowledgement of the strengths and limitations of these methods. The book opens with an extensive and detailed section offering definitions

  9. Performance of X-ray equipment used for conventional radiographic examinations of children

    International Nuclear Information System (INIS)

    Lacerda, Marco A.S.; Silva, Teogenes A. da; Khoury, Helen J.

    2009-01-01

    The performance of X-ray equipment that are used for conventional X-ray examinations of children in four hospitals of Belo Horizonte, Brazil, was evaluated. The methodology proposed by the Brazilian authority for radiation protection in diagnostic radiology was adopted. The performance tests were carried out in six X-ray machines and they consisted of measurements and determination of the X-ray tube output, linearity and constancy of radiation output, accuracy and reproducibility of the exposure time and tube potential, half-value layer (HVL), light field / X-ray field alignment and accuracy of the X-ray field indicator. It was observed that only one hospital had the suitable equipment for X-ray examinations of children. Results showed that all six equipment of the four hospitals presented unsatisfactory performance in some quality control tests. Only for some combinations of the exposure parameters, generally employed in pediatric X-ray examinations, some equipment complied with the authority requirements. (author)

  10. Human performance and reliability studies on nuclear power plant

    International Nuclear Information System (INIS)

    Miyaoka, S.

    1988-01-01

    The TMI accident in USA, the Chernobyl accident in USSR and other major accidents overseas have shown that it is necessary to investigate and research human factor problems related to operation, maintenance and others in order to increase the safety and reliability of nuclear power plants. Although a variety of countermeasures have been devised, the accidents and failures due to human factors still occur. So far, the problems related to human factors have not been fundamantally and systematically investigated. Also the data base related to this problem has not been developed. Therefore, the government and electric utility industry began the research on the prevention of the accidents caused by human errors. The basic research is carried out by the government, and the applied research is done by electric utility industry. The Central Research Institute of Electric Power Industry established the Human Factors Research Center on July 1, 1987. The research program in the Human Factors Research Center is divided into the basic research to clarity fundamental human characteristics, the systematic research to apply this information and the analytical research on human error experience. These research activities are reported. (Kako, I.)

  11. Performance of on-site Medical waste disinfection equipment in hospitals of Tabriz, Iran

    Directory of Open Access Journals (Sweden)

    Hassan Taghipour

    2016-10-01

    Full Text Available Background: The number of studies available on the performance of on-site medical waste treatment facilities is rare, to date. The aim of this study was to evaluate the performance of onsite medical waste treatment equipment in hospitals of Tabriz, Iran. Methods: A various range of the on-site medical waste disinfection equipment (autoclave, chemical disinfection, hydroclave, and dry thermal treatment was considered to select 10 out of 22 hospitals in Tabriz to be included in the survey. The apparatus were monitored mechanically, chemically, and biologically for a six months period in all of the selected hospitals. Results: The results of the chemical monitoring (Bowie-Dick tests indicated that 38.9% of the inspected autoclaves had operational problems in pre-vacuum, air leaks, inadequate steam penetration into the waste, and/or vacuum pump. The biological indicators revealed that about 55.55% of the samples were positive. The most of applied devices were not suitable for treating anatomical, pharmaceutical, cytotoxic, and chemical waste. Conclusion: Although on-site medical waste treating facilities have been installed in all the hospitals, the most of infectious-hazardous medical waste generated in the hospitals were deposited into a municipal solid waste landfill, without enough disinfection. The responsible authorities should stringently inspect and evaluate the operation of on-site medical waste treating equipment. An advanced off-site central facility with multi-treatment and disinfection equipment and enough capacity is recommended as an alternative.

  12. High efficiency motors - performance, economy and reliability, by optimisation

    Energy Technology Data Exchange (ETDEWEB)

    Caselotti, P.; Conchetto, A.; Tavner, P.J.

    2000-07-01

    The challenge of the efficiency initiatives in North America and the European Union is to improve performance without reducing power-weight by adding materials and increasing cost. This has been the subject of other papers, Haataja et al Ref2, where the key area has been identified as reducing loss. This paper suggests that addressing the fundamental problem of heat transfer in the TEFC machine, in addition to reducing loss will make it possible to improve performance and still provide competitive products. (orig.)

  13. Suncor maintenance and reliability

    Energy Technology Data Exchange (ETDEWEB)

    Little, S. [Suncor Energy, Calgary, AB (Canada)

    2006-07-01

    Fleet maintenance and reliability at Suncor Energy was discussed in this presentation, with reference to Suncor Energy's primary and support equipment fleets. This paper also discussed Suncor Energy's maintenance and reliability standard involving people, processes and technology. An organizational maturity chart that graphed organizational learning against organizational performance was illustrated. The presentation also reviewed the maintenance and reliability framework; maintenance reliability model; the process overview of the maintenance and reliability standard; a process flow chart of maintenance strategies and programs; and an asset reliability improvement process flow chart. An example of an improvement initiative was included, with reference to a shovel reliability review; a dipper trip reliability investigation; bucket related failures by type and frequency; root cause analysis of the reliability process; and additional actions taken. Last, the presentation provided a graph of the results of the improvement initiative and presented the key lessons learned. tabs., figs.

  14. Improving the Efficiency of Administrative Decision-Making when Monitoring Reliability and Safety of Oil and Gas Equipment

    Directory of Open Access Journals (Sweden)

    Zemenkova Maria

    2016-01-01

    Full Text Available Methodology of rapid assessment of reliability index was developed based on system analysis of technological parameters. Within functioning of on-line monitoring system of reliability index of industrial facility this method allows to increase efficiency of making managerial decisions on technical and preventive maintenance. The technique is based on the analysis of technological parameters of operational modes of pipeline transport facilities registered by dispatcher controls. The created technique can be used by the operating, research, design institutes and oil and gas transport enterprises when declaring industrial safety. The received mathematical models allow federal services of supervision, the independent expert organizations to predict the development of reliability in the registered block of dispatching data either in real time mode, or taking into account the dynamics of service conditions of the object.

  15. Towards Reliable Evaluation of Anomaly-Based Intrusion Detection Performance

    Science.gov (United States)

    Viswanathan, Arun

    2012-01-01

    This report describes the results of research into the effects of environment-induced noise on the evaluation process for anomaly detectors in the cyber security domain. This research was conducted during a 10-week summer internship program from the 19th of August, 2012 to the 23rd of August, 2012 at the Jet Propulsion Laboratory in Pasadena, California. The research performed lies within the larger context of the Los Angeles Department of Water and Power (LADWP) Smart Grid cyber security project, a Department of Energy (DoE) funded effort involving the Jet Propulsion Laboratory, California Institute of Technology and the University of Southern California/ Information Sciences Institute. The results of the present effort constitute an important contribution towards building more rigorous evaluation paradigms for anomaly-based intrusion detectors in complex cyber physical systems such as the Smart Grid. Anomaly detection is a key strategy for cyber intrusion detection and operates by identifying deviations from profiles of nominal behavior and are thus conceptually appealing for detecting "novel" attacks. Evaluating the performance of such a detector requires assessing: (a) how well it captures the model of nominal behavior, and (b) how well it detects attacks (deviations from normality). Current evaluation methods produce results that give insufficient insight into the operation of a detector, inevitably resulting in a significantly poor characterization of a detectors performance. In this work, we first describe a preliminary taxonomy of key evaluation constructs that are necessary for establishing rigor in the evaluation regime of an anomaly detector. We then focus on clarifying the impact of the operational environment on the manifestation of attacks in monitored data. We show how dynamic and evolving environments can introduce high variability into the data stream perturbing detector performance. Prior research has focused on understanding the impact of this

  16. A reliable measure of footwear upper comfort enabled by an innovative sock equipped with textile pressure sensors.

    Science.gov (United States)

    Herbaut, Alexis; Simoneau-Buessinger, Emilie; Barbier, Franck; Cannard, Francis; Guéguen, Nils

    2016-10-01

    Footwear comfort is essential and pressure distribution on the foot was shown as a relevant objective measurement to assess it. However, asperities on the foot sides, especially the metatarsals and the instep, make its evaluation difficult with available equipment. Thus, a sock equipped with textile pressure sensors was designed. Results from the mechanical tests showed a high linearity of the sensor response under incremental loadings and allowed to determine the regression equation to convert voltage values into pressure measurements. The sensor response was also highly repeatable and the creep under constant loading was low. Pressure measurements on human feet associated with a perception questionnaire exhibited that significant relationships existed between pressure and comfort perceived on the first, the third and the fifth metatarsals and top of the instep. Practitioner Summary: A sock equipped with textile sensors was validated for measuring the pressure on the foot top, medial and lateral sides to evaluate footwear comfort. This device may be relevant to help individuals with low sensitivity, such as children, elderly or neuropathic, to choose the shoes that fit the best.

  17. A Valid and Reliable Tool to Assess Nursing Students` Clinical Performance

    OpenAIRE

    Mehrnoosh Pazargadi; Tahereh Ashktorab; Sharareh Khosravi; Hamid Alavi majd

    2013-01-01

    Background: The necessity of a valid and reliable assessment tool is one of the most repeated issues in nursing students` clinical evaluation. But it is believed that present tools are not mostly valid and can not assess students` performance properly.Objectives: This study was conducted to design a valid and reliable assessment tool for evaluating nursing students` performance in clinical education.Methods: In this methodological study considering nursing students` performance definition; th...

  18. Validity and reliability of tests determining performance-related components of wheelchair basketball

    NARCIS (Netherlands)

    de Groot, Sonja; Balvers, Inge J.M.; Kouwenhoven, Sanne M.; Janssen, Thomas W.J.

    The purpose of this study was to investigate the reliability and validity of wheelchair basketball field tests. Nineteen wheelchair basketball players performed 10 test items twice to determine the reliability. The validity of the tests was assessed by relating the scores to the players'

  19. Validity and reliability of tests determining performance-related components of wheelchair basketball

    NARCIS (Netherlands)

    De Groot, Sonja; Balvers, Inge J. M.; Kouwenhoven, Sanne M.; Janssen, Thomas W. J.

    2012-01-01

    The purpose of this study was to investigate the reliability and validity of wheelchair basketball field tests. Nineteen wheelchair basketball players performed 10 test items twice to determine the reliability. The validity of the tests was assessed by relating the scores to the players'

  20. Comparison of reading performance tests concerning difficulty of sentences and paragraphs and their reliability

    NARCIS (Netherlands)

    Brussee, T.; van Nispen, R.M.A.; Klerkx, E.M.F.J.; Knol, D.L.; van Rens, G.H.M.B.

    2015-01-01

    In research and practice, sentences or paragraphs of reading tests may be randomly chosen to assess reading performance. This means that in addition to test reliability, all sentences or paragraphs should be reliable and equally difficult to read. The sentences and paragraphs of five (un-)

  1. Cryogenics system: strategy to achieve nominal performance and reliable operation

    International Nuclear Information System (INIS)

    Bremer, J.; Brodzinski, K.; Casas, J.; Claudet, S.; Delikaris, D.; Delruelle, N.; Ferlin, G.; Fluder, C.; Perin, A.; Perinic, G.; Pezzetti, M.; Pirotte, O.; Tavian, L.; Wagner, U.

    2012-01-01

    During the LHC operation in 2010 and 2011, the cryogenic system has achieved an availability level fulfilling the overall requirement. To reach this level, the cryogenic system has profited like many other beam-dependent systems from the reduced beam parameters. Therefore, impacts of some failures occurred during the LHC operation were mitigated by using the over-capacity margin, the existing built-in redundancy in between adjacent sector cryogenic plants and the 'cannibalization' of spares on two idle cryogenic plants. These two first years of operation were also crucial to identify the weaknesses of the present cryogenic maintenance plan and new issues like SEUs. After the LS1, nominal beam parameters are expected and the mitigated measures will be less effective or not applicable at all. Consequently, a consolidation plan to improve the MTBF and the MTTR of the LHC cryogenic system is under definition. Concerning shutdown periods, the present cryogenic sectorization imposes some restrictions in the type of interventions (e.g. cryo-magnet removal) which can be done without affecting the operating conditions of the adjacent sector. This creates additional constrains and possible extra down-time in the schedule of the shutdowns including the hardware commissioning. This presentation focuses on the consolidation plan foreseen during the LS1 to improve the performance of the LHC cryogenic system in terms of availability and sectorization. (authors)

  2. Reliability and performance experience with flat-plate photovoltaic modules

    Science.gov (United States)

    Ross, R. G., Jr.

    1982-01-01

    Statistical models developed to define the most likely sources of photovoltaic (PV) array failures and the optimum method of allowing for the defects in order to achieve a 20 yr lifetime with acceptable performance degradation are summarized. Significant parameters were the cost of energy, annual power output, initial cost, replacement cost, rate of module replacement, the discount rate, and the plant lifetime. Acceptable degradation allocations were calculated to be 0.0001 cell failures/yr, 0.005 module failures/yr, 0.05 power loss/yr, a 0.01 rate of power loss/yr, and a 25 yr module wear-out length. Circuit redundancy techniques were determined to offset cell failures using fault tolerant designs such as series/parallel and bypass diode arrangements. Screening processes have been devised to eliminate cells that will crack in operation, and multiple electrical contacts at each cell compensate for the cells which escape the screening test and then crack when installed. The 20 yr array lifetime is expected to be achieved in the near-term.

  3. Development and performance of inspection equipment for pressure tubes in Fugen

    International Nuclear Information System (INIS)

    Naruo, Kazuteru; Tanimoto, Ken-ichi; Ohta, Takeo; Nakamura, Takahisa; Imaizumi, Kiyoshi.

    1984-01-01

    The pressure tubes of Fugen are the important equipment as the many tubes compose the core, and since they are made of Zr-2.5% Nb alloy which has been used for the first time in Japan, they have become the object of monitoring (the follow-up investigation of the change of inside diameter, the presence of defects and so on) in addition to the in-service inspection. In this paper, on the inspection equipment for pressure tubes, that has been developed independently by the Power Reactor and Nuclear Fuel Development Corp. in order to carry out the ISI and monitoring, the course of development and the construction and the performance are reported, and the results of having used it for the fourth regular inspection of Fugen are described. The 10-year plan of the ISI and monitoring of pressure tubes is shown. The core of Fugen is composed of 224 pressure tubes, therefore, the inspection is carried out by sampling inspection. The monitoring is carried out on four tubes for the follow-up investigation and one tube that shows the severest operation history at the time of inspection. The equipment performs ultrasonic flaw detection, the measurement of inside diameter and the visual inspection of internal surface. (Kako, I.)

  4. Forward lunge as a functional performance test in ACL deficient subjects: test-retest reliability

    DEFF Research Database (Denmark)

    Alkjaer, Tine; Henriksen, Marius; Dyhre-Poulsen, Poul

    2009-01-01

    The forward lunge movement may be used as a functional performance test of anterior cruciate ligament (ACL) deficient and reconstructed subjects. The purposes were 1) to determine the test-retest reliability of a forward lunge in healthy subjects and 2) to determine the required numbers...... of repetitions necessary to yield satisfactory reliability. Nineteen healthy subjects performed four trials of a forward lunge on two different days. The movement time, impulses of the ground reaction forces (IFz, IFy), knee joint kinematics and dynamics during the forward lunge were calculated. The relative...... reliability was determined by calculation of Intraclass Correlation Coefficients (ICC). The IFz, IFy and the positive work of the knee extensors showed excellent reliability (ICC >0.75). All other variables demonstrated acceptable reliability (0.4>ICCreliability increased when more than...

  5. Pump performance and reliability follow-up by the French Safety Authorities

    International Nuclear Information System (INIS)

    Clausner, J.P.; De La Ronciere, X.; Scott de Martinville, E.; Courbiere, P.

    1990-12-01

    This paper will present, through actual examples, the methodology of the performance and reliability safety-related pumps evaluation applied by the French Safety Authorities and the lessons drawn from this evaluation

  6. Impact of scaling on the performance and reliability degradation of metal-contacts in NEMS devices

    KAUST Repository

    Dadgour, Hamed F.; Hussain, Muhammad Mustafa; Cassell, Alan M.; Singh, Navab R.; Banerjee, Kaustav

    2011-01-01

    thoroughly investigated in the literature. Such a study is essential because metal contacts play a critical role in determining the overall performance and reliability of NEMS. Therefore, the comprehensive analytical study presented in this paper highlights

  7. Improved Yield, Performance and Reliability of High-Actuator-Count Deformable Mirrors, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The project team will conduct processing and design research aimed at improving yield, performance, and reliability of high-actuator-count micro-electro-mechanical...

  8. Performance Test of the Salt transfer and Pellet fabrication of UCl3 Making Equipment for Electrorefining

    International Nuclear Information System (INIS)

    Woo, M. S.; Jin, H. J.; Park, G. I.; Park, S. B.

    2014-01-01

    The process to produce a uranium chloride salt includes two steps: a reaction process of gaseous chlorine with liquid cadmium to form the CdCl 2 occurring in a Cd layer, followed by a process to produce UCl 3 by the reaction of U in the LiCl-KCl eutectic salt and CdCl 2 . Chemical reaction is next chlorination reaction; - Cd chlorination : Cd + Cl2 → CdCl 2 - U chlorination : 3CdCl2 + 2U → 3Cd + 2UCl 3 The apparatus for producing UCl 3 consists of a chlorine gas generator, a uranium chlorinator, a Cd distiller, the pelletizer, a off-gas wet scrubber and a dry scrubber. Salt transfer system set among reactors to transfer salt at 500 .deg. C. The temperature of the reactants is maintained at about 600 .deg. C. After the reaction is completed in the uranium chlorinator, The Salt product is transferred to the Cd distiller to decrease residual Cd concentration in the salts, and then salt is transferred to the mould of pelletizer by a transfer system to fabricate pellet type salt. Performance test of the salt transfer and pellet fabrication of its equipment was tested in this work. Performance test of the salt transfer and pellet fabrication of UCl3 making equipment for Electrorefining carried out in this work. The result of equipment test is that melted salt at 600 .deg. C was easy transferred by salt transfer equipment heated at 500 .deg. C. In this time, salt transfer was carried out by argon gas pressurization at 3bar. When velocity of salt transfer was controlled under reduce pressure, velocity of salt transfer was difficult to control. And when salt pellet was fabricated by the mold of pelletizer heated at 90 .deg. C better than mold of pelletizer heated at 200 .deg. C because salt melted prevent leakage from mold of pelletizer

  9. A Fast Optimization Method for Reliability and Performance of Cloud Services Composition Application

    Directory of Open Access Journals (Sweden)

    Zhao Wu

    2013-01-01

    Full Text Available At present the cloud computing is one of the newest trends of distributed computation, which is propelling another important revolution of software industry. The cloud services composition is one of the key techniques in software development. The optimization for reliability and performance of cloud services composition application, which is a typical stochastic optimization problem, is confronted with severe challenges due to its randomness and long transaction, as well as the characteristics of the cloud computing resources such as openness and dynamic. The traditional reliability and performance optimization techniques, for example, Markov model and state space analysis and so forth, have some defects such as being too time consuming and easy to cause state space explosion and unsatisfied the assumptions of component execution independence. To overcome these defects, we propose a fast optimization method for reliability and performance of cloud services composition application based on universal generating function and genetic algorithm in this paper. At first, a reliability and performance model for cloud service composition application based on the multiple state system theory is presented. Then the reliability and performance definition based on universal generating function is proposed. Based on this, a fast reliability and performance optimization algorithm is presented. In the end, the illustrative examples are given.

  10. MONITORING OF THE PERFORMANCE EFFICIENCY OF THE EQUIPMENT AT THE ENTERPRISES OF AVIATION INSTRUMENTATION

    Directory of Open Access Journals (Sweden)

    Petr P. Dobrov

    2016-01-01

    Full Text Available The article elaborates the proposals to improve the systems for monitoring performance of the equipment at the enterprises of aviation instrument. The relevance of the study due to the fact that the aviation instrument-making industry of the Russian Federation can play a role as a key factor in enhancing the competitiveness of the national economy. Currently, the global aviation market is fairly saturated, it competition is not between individual companies and between the aviation powers. The role of an efficient industrial production is largely dependent on the amount, structure, technical condition and the level of utilization of fixed assets. Specificity of high-tech high-tech production presupposes the existence of a specific fleet of expensive and unique equipment; a high degree of novelty products, single or small-scale type of production that determines the high cost of production of a unit of production; high demands on the staff . The paper noted that the production capacity is an essential tool for production planning process, which allows to determine the optimal work shifts Park main technological equipment and production program to justify the enterprises of sphere of aviation instrument. On the basis of the modification of OEE method, a stochastic model is proposed, which allows to display the efficiency of the productive capacity of the high-tech enterprises of sphere of aviation instrument in the form of multi-dimensional size and much more accurately identify the relationship between its elements.

  11. Can High-Performance Equipment Lead to a Low-Performance Building?

    Energy Technology Data Exchange (ETDEWEB)

    Jonlin, Duane; Thornton, Brian A.; Rosenberg, Michael I.

    2016-08-22

    The performance-based compliance alternative available in most energy codes, intended to provide energy efficiency equivalent to that of prescriptive compliance while allowing innovation and design flexibility, can instead result in sub-standard energy performance in both the short and the long term. The potential deficiencies in modeled buildings originate with subtleties in the energy modeling rules, allowing building systems that consume more energy than their real-world, prescriptively-designed counterparts. This performance gap is exacerbated over subsequent decades as less efficient permanent features of the building remain while elements with shorter lives are regularly upgraded in most buildings. This paper summarizes an investigation into the topic for Pacific Northwest National Laboratory and the City of Seattle, including identification of the principal deficiencies exploited in the modeling path, and several potential code amendments that could resolve these deficiencies and establish better equivalency between prescriptive and performance compliance paths. The study, focusing on Seattle and Washington State energy codes, offers lessons and implications for other jurisdictions and energy codes.

  12. Controlled air incinerator for radioactive waste. Volume I. Rationale, process, equipment, performance, and recommendations

    International Nuclear Information System (INIS)

    Neuls, A.S.; Draper, W.E.; Koenig, R.A.; Newmyer, J.M.; Warner, C.L.

    1982-11-01

    This two-volume report is a detailed design and operating documentation of the Los Alamos National Laboratory Controlled Air Incinerator (CAI) and is an aid to technology transfer to other Department of Energy contractor sites and the commercial sector. Volume I describes the CAI process, equipment, and performance, and it recommends modifications based on Los Alamos experience. It provides the necessary information for conceptual design and feasibility studies. Volume II provides descriptive engineering information such as drawings specifications, calculations, and costs. It aids duplication of the process at other facilities

  13. Los Alamos Controlled Air Incinerator for radioactive waste. Volume I. Rationale, process, equipment, performance, and recommendations

    International Nuclear Information System (INIS)

    Neuls, A.S.; Draper, W.E.; Koenig, R.A.; Newmyer, J.M.; Warner, C.L.

    1982-08-01

    This two-volume report is a detailed design and operating documentation of the Los Alamos National Laboratory Controlled Air Incinerator (CAI) and is an aid to technology transfer to other Department of Energy contractor sites and the commercial sector. Volume I describes the CAI process, equipment, and performance, and it recommends modifications based on Los Alamos experience. It provides the necessary information for conceptual design and feasibility studies. Volume II provides descriptive engineering information such as drawing, specifications, calculations, and costs. It aids duplication of the process at other facilities

  14. Evaluation of mammography equipment performance, dose and image quality in five Latin American countries

    Science.gov (United States)

    Brandan, M.-E.; Ruiz-Trejo, C.; Caspani, C. E. M.; Fleitas, I.; de-la-Mora, R.; Miranda, A. A.; Plazas, M.-C.; Betancourt, C.-M.; Borras, C.

    2001-10-01

    Under the auspices of PAHO/WHO, a multicentric investigation is carried out in five Latin American countries. Its aim is to correlate quality indicators of radiology services with the accuracy of the radiological interpretation as determined by a panel of radiology experts. We present preliminary results from mammographic imaging facilities. Evaluation of the equipment performance and dose measurements in 21 mammographic units show that, on the average, 75% of the units comply with recommendations issued by various organizations. An independent evaluation of the quality of the clinical images show strong variations among the different radiological services.

  15. General guidelines about performance specifications for purchasing equipment for x-ray diagnostics, with comments

    International Nuclear Information System (INIS)

    1995-12-01

    These general guidelines are intended to be used as a basis for what requirements are reasonable from a radiation protection point of view and should be part of the contract in connection with the purchase of equipment for x-ray diagnostics. Technical performance requirements are addressed as well as items like documentation, instructions for use and education and training. The guidelines are also useful for the design of quality assurance programs. In the comments in addition to these guidelines legal aspects are noted, including a list of relevant laws, regulations and directives. Standards, both national and international, within the field are referred to with a short description of their content. 40 refs

  16. Los Alamos Controlled Air Incinerator for radioactive waste. Volume I. Rationale, process, equipment, performance, and recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Neuls, A.S.; Draper, W.E.; Koenig, R.A.; Newmyer, J.M.; Warner, C.L.

    1982-08-01

    This two-volume report is a detailed design and operating documentation of the Los Alamos National Laboratory Controlled Air Incinerator (CAI) and is an aid to technology transfer to other Department of Energy contractor sites and the commercial sector. Volume I describes the CAI process, equipment, and performance, and it recommends modifications based on Los Alamos experience. It provides the necessary information for conceptual design and feasibility studies. Volume II provides descriptive engineering information such as drawing, specifications, calculations, and costs. It aids duplication of the process at other facilities.

  17. Evaluation of mammography equipment performance, dose and image quality in five Latin American countries

    International Nuclear Information System (INIS)

    Brandan, M.-E.; Ruiz-Trejo, C.; Caspani, C. E. M.; Fleitas, I.; Mora, R. de la; Miranda, A. A.; Plazas, M.-C.; Betancourt, C.-M.; Borras, C.

    2001-01-01

    Under the auspices of PAHO/WHO, a multicentric investigation is carried out in five Latin American countries. Its aim is to correlate quality indicators of radiology services with the accuracy of the radiological interpretation as determined by a panel of radiology experts. We present preliminary results from mammographic imaging facilities. Evaluation of the equipment performance and dose measurements in 21 mammographic units show that, on the average, 75% of the units comply with recommendations issued by various organizations. An independent evaluation of the quality of the clinical images show strong variations among the different radiological services

  18. Quantification of glibenclamide in cleaning samples of pharmaceutical equipment through high performance liquid chromatography

    International Nuclear Information System (INIS)

    Baeza Fonte, Alen Nils; Diaz Aguila, Elsa Eneida; Martinez Alfonso; Nancy

    2012-01-01

    to submit a selective analytical method for quantization of glibenclamide in cleaning samples of pharmaceutical equipment using high performance liquid chromatography. The mobile phase consisted of an equal mixing of acetonitrile/phosphate buffer KH 2 PO 4 ; with 0.037 mol/L concentration pH 5.25 and flow of 1.5 mL/min, in a Nucleosil 100 C8 column. Glibenclamide was injected with progesterone as internal standard and using an UV detector= 230 nm

  19. General guidelines about performance specifications for purchasing equipment for x-ray diagnostics, with comments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    These general guidelines are intended to be used as a basis for what requirements are reasonable from a radiation protection point of view and should be part of the contract in connection with the purchase of equipment for x-ray diagnostics. Technical performance requirements are addressed as well as items like documentation, instructions for use and education and training. The guidelines are also useful for the design of quality assurance programs. In the comments in addition to these guidelines legal aspects are noted, including a list of relevant laws, regulations and directives. Standards, both national and international, within the field are referred to with a short description of their content. 40 refs.

  20. Characterization and performances of DOSION, a dosimetry equipment dedicated to radiobiology experiments taking place at GANIL

    Energy Technology Data Exchange (ETDEWEB)

    Boissonnat, Guillaume, E-mail: boissonnat@lpccaen.in2p3.fr [LPC (Normandie Univ-ENSICAEN-UNICAEN-CNRS/IN2P3), 6 Bd Maréchal Juin, 14050 Caen (France); Fontbonne, Jean-Marc [LPC (Normandie Univ-ENSICAEN-UNICAEN-CNRS/IN2P3), 6 Bd Maréchal Juin, 14050 Caen (France); Balanzat, Emmanuel [CIMAP (CEA/DSM-CNRS/INP-ENSICAEN-UNICAEN), Bd Henri Becquerel, 14076 Caen (France); Boumard, Frederic; Carniol, Benjamin [LPC (Normandie Univ-ENSICAEN-UNICAEN-CNRS/IN2P3), 6 Bd Maréchal Juin, 14050 Caen (France); Cassimi, Amine [CIMAP (CEA/DSM-CNRS/INP-ENSICAEN-UNICAEN), Bd Henri Becquerel, 14076 Caen (France); Colin, Jean; Cussol, Daniel; Etasse, David; Fontbonne, Cathy [LPC (Normandie Univ-ENSICAEN-UNICAEN-CNRS/IN2P3), 6 Bd Maréchal Juin, 14050 Caen (France); Frelin, Anne-Marie [GANIL (CEA/DSM-CNRS/IN2P3), Bd Henri Becquerel, 14076 Caen (France); Hommet, Jean; Salvador, Samuel [LPC (Normandie Univ-ENSICAEN-UNICAEN-CNRS/IN2P3), 6 Bd Maréchal Juin, 14050 Caen (France)

    2017-06-01

    Currently, radiobiology experiments using heavy ions at GANIL (Grand Accélérateur National d′Ions Lourds) are conducted under the supervision of the CIMAP (Center for research on Ions, MAterials and Photonics). In this context, a new beam monitoring equipment named DOSION has been developed. It allows to perform measurements of accurate fluence and dose maps in near real time for each biological sample irradiated. In this paper, we present the detection system, its design, performances, calibration protocol and measurements performed during radiobiology experiments. This setup is currently available for any radiobiology experiments if one wishes to correlate one's own sample analysis to state-of-the-art dosimetric references.

  1. reliability reliability

    African Journals Online (AJOL)

    eobe

    Corresponding author, Tel: +234-703. RELIABILITY .... V , , given by the code of practice. However, checks must .... an optimization procedure over the failure domain F corresponding .... of Concrete Members based on Utility Theory,. Technical ...

  2. Performance and reliability of TPE-2 device with pulsed high power source

    International Nuclear Information System (INIS)

    Sato, Y.; Takeda, S.; Kiyama, S.

    1987-01-01

    The performance and the reliability of TPE-2 device with pulsed high power sources are described. To obtain the stable high beta plasma, the reproducibility and the reliability of the pulsed power sources must be maintained. A new power crowbar system with high efficiency and the switches with low jitter time are adopted to the bank system. A monitor system which always watches the operational states of the switches is developed too, and applied for the fast rising capacitor banks of TPE-2 device. The reliable operation for the bank has been realized, based on the data of switch monitor system

  3. Reliability modeling of degradation of products with multiple performance characteristics based on gamma processes

    International Nuclear Information System (INIS)

    Pan Zhengqiang; Balakrishnan, Narayanaswamy

    2011-01-01

    Many highly reliable products usually have complex structure, with their reliability being evaluated by two or more performance characteristics. In certain physical situations, the degradation of these performance characteristics would be always positive and strictly increasing. In such a case, the gamma process is usually considered as a degradation process due to its independent and non-negative increments properties. In this paper, we suppose that a product has two dependent performance characteristics and that their degradation can be modeled by gamma processes. For such a bivariate degradation involving two performance characteristics, we propose to use a bivariate Birnbaum-Saunders distribution and its marginal distributions to approximate the reliability function. Inferential method for the corresponding model parameters is then developed. Finally, for an illustration of the proposed model and method, a numerical example about fatigue cracks is discussed and some computational results are presented.

  4. Reliability and validity of match performance analysis in soccer : a multidimensional qualitative evaluation of opponent interaction

    OpenAIRE

    Tenga, Albin

    2010-01-01

    Avhandling (doktorgrad) – Norges idrettshøgskole, 2010. Match performance analysis is widely used as a method for studying technical, tactical and physical aspects of player and team performance in a soccer match. Therefore, ensuring the validity and reliability of the collected data is important for match performance analysis to meet its intents and purposes effectively. However, most studies on soccer match performance use unidimensional frequency data based on analyses done ...

  5. Embedded Sensors and Controls to Improve Component Performance and Reliability Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Kisner, R.; Melin, A.; Burress, T.; Fugate, D.; Holcomb, D.; Wilgen, J.; Miller, J.; Wilson, D.; Silva, P.; Whitlow, L.; Peretz, F.

    2012-09-15

    The objective of this project is to demonstrate improved reliability and increased performance made possible by deeply embedding instrumentation and controls (I&C) in nuclear power plant (NPP) components and systems. The project is employing a highly instrumented canned rotor, magnetic bearing, fluoride salt pump as its I&C technology demonstration platform. I&C is intimately part of the basic millisecond-by-millisecond functioning of the system; treating I&C as an integral part of the system design is innovative and will allow significant improvement in capabilities and performance. As systems become more complex and greater performance is required, traditional I&C design techniques become inadequate and more advanced I&C needs to be applied. New I&C techniques enable optimal and reliable performance and tolerance of noise and uncertainties in the system rather than merely monitoring quasistable performance. Traditionally, I&C has been incorporated in NPP components after the design is nearly complete; adequate performance was obtained through over-design. By incorporating I&C at the beginning of the design phase, the control system can provide superior performance and reliability and enable designs that are otherwise impossible. This report describes the progress and status of the project and provides a conceptual design overview for the platform to demonstrate the performance and reliability improvements enabled by advanced embedded I&C.

  6. The Reliability of In-Training Assessment when Performance Improvement Is Taken into Account

    Science.gov (United States)

    van Lohuizen, Mirjam T.; Kuks, Jan B. M.; van Hell, Elisabeth A.; Raat, A. N.; Stewart, Roy E.; Cohen-Schotanus, Janke

    2010-01-01

    During in-training assessment students are frequently assessed over a longer period of time and therefore it can be expected that their performance will improve. We studied whether there really is a measurable performance improvement when students are assessed over an extended period of time and how this improvement affects the reliability of the…

  7. The effect of plant aging on equipment qualification and human performance issues related to license renewal

    International Nuclear Information System (INIS)

    Gunther, W.E.; Higgins, J.C.; Aggarwal, S.K.

    1991-01-01

    The aging of nuclear power plants is one of the most important issues facing the nuclear industry worldwide. Aging encompasses as forms of degradation to nuclear power plant components, systems, and structures that result from exposure to environmental conditions or from operational stresses. Both the degradation from aging and actions taken to address the aging, such as increased maintenance and testing, can significantly impact human performance in the plant. Research into the causes and effects of aging as obtained through the assessment of operating experience and testing have raised questions regarding the adequacy of existing industry standards for addressing the concerns raised by this research. This paper discusses these issues, with particular emphasis in the area of equipment qualification and human performance

  8. High performance gamma measurements of equipment retrieved from Hanford high-level nuclear waste tanks

    Energy Technology Data Exchange (ETDEWEB)

    Troyer, G.L.

    1997-03-17

    The cleanup of high level defense nuclear waste at the Hanford site presents several progressive challenges. Among these is the removal and disposal of various components from buried active waste tanks to allow new equipment insertion or hazards mitigation. A unique automated retrieval system at the tank provides for retrieval, high pressure washing, inventory measurement, and containment for disposal. Key to the inventory measurement is a three detector HPGe high performance gamma spectroscopy system capable of recovering data at up to 90% saturation (200,000 counts per second). Data recovery is based on a unique embedded electronic pulser and specialized software to report the inventory. Each of the detectors have different shielding specified through Monte Carlo simulation with the MCNP program. This shielding provides performance over a dynamic range of eight orders of magnitude. System description, calibration issues and operational experiences are discussed.

  9. The effect of plant aging on equipment qualification and human performance issues related to license renewal

    Energy Technology Data Exchange (ETDEWEB)

    Gunther, W.E.; Higgins, J.C. [Brookhaven National Lab., Upton, NY (United States); Aggarwal, S.K. [Nuclear Regulatory Commission, Washington, DC (United States)

    1991-12-31

    The aging of nuclear power plants is one of the most important issues facing the nuclear industry worldwide. Aging encompasses as forms of degradation to nuclear power plant components, systems, and structures that result from exposure to environmental conditions or from operational stresses. Both the degradation from aging and actions taken to address the aging, such as increased maintenance and testing, can significantly impact human performance in the plant. Research into the causes and effects of aging as obtained through the assessment of operating experience and testing have raised questions regarding the adequacy of existing industry standards for addressing the concerns raised by this research. This paper discusses these issues, with particular emphasis in the area of equipment qualification and human performance.

  10. The effect of plant aging on equipment qualification and human performance issues related to license renewal

    Energy Technology Data Exchange (ETDEWEB)

    Gunther, W.E.; Higgins, J.C. (Brookhaven National Lab., Upton, NY (United States)); Aggarwal, S.K. (Nuclear Regulatory Commission, Washington, DC (United States))

    1991-01-01

    The aging of nuclear power plants is one of the most important issues facing the nuclear industry worldwide. Aging encompasses as forms of degradation to nuclear power plant components, systems, and structures that result from exposure to environmental conditions or from operational stresses. Both the degradation from aging and actions taken to address the aging, such as increased maintenance and testing, can significantly impact human performance in the plant. Research into the causes and effects of aging as obtained through the assessment of operating experience and testing have raised questions regarding the adequacy of existing industry standards for addressing the concerns raised by this research. This paper discusses these issues, with particular emphasis in the area of equipment qualification and human performance.

  11. How the reverse supply chain impacts the financial performance of original equipment manufacturers

    DEFF Research Database (Denmark)

    Larsen, Samuel

    This thesis examines the financial impact of a firm’s reverse supply chain (RSC). Specifically, the thesis examines the two questions of how the RSC can contribute to the financial performance of the firm and which factors are decisive for the RSC’s financial contribution. The thesis focuses...... on original equipment manufacturers. The thesis results show that the RSC can contribute to the financial performance of the firm in more than 20 different ways, which the thesis defines as functions of the RSC. Examples of RSC-functions are 1) resale of recovered end-products to price-focused market segments...... in the firm’s primary markets, 2) resale to customers in new markets (in e.g. emerging economies), and 3) sale of used materials back the firm’s original material suppliers. The firm’ RSC can conduct several RSC-functions simultaneously and the financial benefits from operating these RSC-functions differ...

  12. High performance gamma measurements of equipment retrieved from Hanford high-level nuclear waste tanks

    International Nuclear Information System (INIS)

    Troyer, G.L.

    1997-01-01

    The cleanup of high level defense nuclear waste at the Hanford site presents several progressive challenges. Among these is the removal and disposal of various components from buried active waste tanks to allow new equipment insertion or hazards mitigation. A unique automated retrieval system at the tank provides for retrieval, high pressure washing, inventory measurement, and containment for disposal. Key to the inventory measurement is a three detector HPGe high performance gamma spectroscopy system capable of recovering data at up to 90% saturation (200,000 counts per second). Data recovery is based on a unique embedded electronic pulser and specialized software to report the inventory. Each of the detectors have different shielding specified through Monte Carlo simulation with the MCNP program. This shielding provides performance over a dynamic range of eight orders of magnitude. System description, calibration issues and operational experiences are discussed

  13. Reliability and Validity of the Turkish Version of the Job Performance Scale Instrument.

    Science.gov (United States)

    Harmanci Seren, Arzu Kader; Tuna, Rujnan; Eskin Bacaksiz, Feride

    2018-02-01

    Objective measurement of the job performance of nursing staff using valid and reliable instruments is important in the evaluation of healthcare quality. A current, valid, and reliable instrument that specifically measures the performance of nurses is required for this purpose. The aim of this study was to determine the validity and reliability of the Turkish version of the Job Performance Instrument. This study used a methodological design and a sample of 240 nurses working at different units in four hospitals in Istanbul, Turkey. A descriptive data form, the Job Performance Scale, and the Employee Performance Scale were used to collect data. Data were analyzed using IBM SPSS Statistics Version 21.0 and LISREL Version 8.51. On the basis of the data analysis, the instrument was revised. Some items were deleted, and subscales were combined. The Turkish version of the Job Performance Instrument was determined to be valid and reliable to measure the performance of nurses. The instrument is suitable for evaluating current nursing roles.

  14. Design of thermoelectric modules for both mechanical reliability and performance using FE simulation

    DEFF Research Database (Denmark)

    Sarhadi, Ali; Bjørk, Rasmus; Pryds, Nini

    for these two objectives. The current study deals with FE simulation of the TE modules to optimize their geometrical dimension in terms of mechanical reliability and performance. First, FE simulation of a TE module consisting of bismuth telluride alloys is carried out and the induced thermal stresses, output......, the geometrical dimensions of the TE elements for both mechanical reliability and performance are optimized to obtain a compromise design. The present work provides a basis for optimizing the TE modules in terms of their life time and performance.......Thermo-mechanical modeling of the TE modules provides an efficient tool for assessing the mechanical strength of the modules against the induced thermal stresses and subsequently optimizing them in terms of the mechanical reliability. However, the design of TE modules in terms of mechanical...

  15. Evaluating performance characteristics of x-ray equipment and film systems without the use of electronic measurement and/or special instruments

    International Nuclear Information System (INIS)

    Bianchi, M.F.; DeNitto, C.; Liscio, A.; Scala, N.

    2004-01-01

    Measurement and control of characteristics of NDT equipment and system that produce output to be interpreted by inspector is one of the most important tools for NDT reliability. Control activity should be based on: initial accurate measurement and calibration; periodical check to assure maintenance of calibration status; and, immediate verification and corrective action when any malfunctioning is suspected. 'Self-calibration' intended as capability of NDT facility to calibrate and control its own equipment and systems is very important for continuous and reliable activity. Typical approach based on this philosophy is ASTM E317 'Standard Practice for Evaluating Performance Characteristics of Ultrasonic Pulse-Echo Examination Instruments and Systems Without the Use of Electronic Measurement Instruments' that is applicable to shop or field conditions. Is 'Self-calibration' applicable to radiographic system too? Many characteristics can be self-determined according to existing practices and methods, but other ones require assistance and cooperation of supplier both for film system and x-ray equipment. A certified film system being controlled by pre-exposed filmstrips can be adopted as 'measurement device' for X-ray output concerning both intensity and contrast. Basically x-ray equipment manufacturer performs initial accurate measurement and calibration using electronic measurement and/or special instrumentation as necessary. Then specific film set on 'low-price' blocks and specimens is produced according to standard practice whose guidelines are supplied by this paper. Film set, blocks, specimens and results referred to specific film system will be the reference kit for periodical check in NDT facility. This paper supplies some guidelines for standard practice based on testing using mainly GE Inspection Technologies radiographic system being available in Avio facilities. (author)

  16. Device Performance and Reliability Improvements of AlGaBN/GaN/Si MOSFET

    Science.gov (United States)

    2016-02-04

    AFRL-AFOSR-JP-TR-2016-0037 Device Performance and Reliablity Improvements of AlGaBN/GaN/Si MOSFET Robert Wallace UNIVERSITY OF TEXAS AT DALLAS Final...GaN/Si MOSFET 5a.  CONTRACT NUMBER 5b.  GRANT NUMBER FA2386-14-1-4069 5c.  PROGRAM ELEMENT NUMBER 61102F 6. AUTHOR(S) Robert Wallace 5d.  PROJECT...AOARD Grant FA2386-14-1-4069 Device Performance and Reliability Improvements of AlGaN/GaN/Si MOSFET US 12 month extension (2014 – 2015) for current

  17. Development of microstructure to optimise mechanical performance of power generation equipment

    International Nuclear Information System (INIS)

    Marshall, P.

    1986-11-01

    The factors responsible for the development of microstructure in CEGB construction ceramics and steels is assessed as a function of composition, thermomechanical treatment, thermal ageing and environmental degradation. The relationships between microstructure and mechanical properties (tensile, toughness, creep and fatigue) of relevance to structures operating in power generation equipment is then developed in quantitative terms. The conclusions from the assessment are as follows: 1 The relationship between microstructure and mechanical properties of construction ceramics and steels used in the power generation industry has been assessed. 2 Factors which significantly influence microstructure and thus mechanical properties are chemical composition, thermomechanical treatment, ageing and environmental degradation. The influence of such microstructural changes in tensile, toughness, fatigue and creep properties of ceramics and steels is assessed. 3 The benefits arising from an understanding of materials behaviour are discussed in terms of improved materials and the assessment of plant performance. (author)

  18. Survey of mammography practice in Croatia: Equipment performance, image quality and dose

    International Nuclear Information System (INIS)

    Faj, D.; Stimac, D.; Ivezic, Z.; Kasabasic, M.; Ivkovic, A.; Posedel, D.; Kubelka, D.; Ilakovac, V.; Brnic, Z.; Bjelac, O.C.

    2008-01-01

    A national audit of mammography equipment performance, image quality and dose has been conducted in Croatia. Film-processing parameters, optical density (OD), average glandular dose (AGD) to the standard breast, viewing conditions and image quality were examined using TOR(MAM) test object. Average film gradient ranged from 2.6 to 3.7, with a mean of 3.1. Tube voltage used for imaging of the standard 45 mm polymethylmethacrylate phantom ranged from 24 to 34 kV, and OD ranged from 0.75 to 1.94 with a mean of 1.26. AGD to the standard breast ranged from 0.4 to 2.3 mGy with a mean of 1.1 mGy. Besides clinical conditions, the authors have imaged the standard phantom in the referent conditions with 28 kV and OD as close as possible to 1.5. Then, AGD ranged from 0.5 to 2.6 mGy with a mean of 1.3 mGy. Image viewing conditions were generally unsatisfying with ambient light up to 500 lx and most of the viewing boxes with luminance between 1000 and 2000 cd per m 2 . TOR(MAM) scoring of images taken in clinical and referent conditions was done by local radiologists in local image viewing conditions and by the referent radiologist in good image viewing conditions. Importance of OD and image viewing conditions for diagnostic information were analysed. The survey showed that the main problem in Croatia is the lack of written quality assurance/quality control (QA/QC) procedures. Consequently, equipment performance, image quality and dose are unstable and activities to improve image quality or to reduce the dose are not evidence-based. This survey also had an educational purpose, introducing in Croatia the QC based on European Commission Guidelines. (authors)

  19. Human Reliability Assessment and Human Performance Evaluation: Research and Analysis Activities at the U.S. NRC

    International Nuclear Information System (INIS)

    Ramey-Smith, A.M.

    1998-01-01

    The author indicates the themes of the six programs identified by the US NRC mission on human performance and human reliability activities. They aim at developing the technical basis to support human performance, at developing and updating a model of human performance and human reliability, at fostering national and international dialogue and cooperation efforts on human performance evaluation, at conducting operating events analysis and database development, and at providing support to human performance and human reliability inspection

  20. A new approach for reliability analysis with time-variant performance characteristics

    International Nuclear Information System (INIS)

    Wang, Zequn; Wang, Pingfeng

    2013-01-01

    Reliability represents safety level in industry practice and may variant due to time-variant operation condition and components deterioration throughout a product life-cycle. Thus, the capability to perform time-variant reliability analysis is of vital importance in practical engineering applications. This paper presents a new approach, referred to as nested extreme response surface (NERS), that can efficiently tackle time dependency issue in time-variant reliability analysis and enable to solve such problem by easily integrating with advanced time-independent tools. The key of the NERS approach is to build a nested response surface of time corresponding to the extreme value of the limit state function by employing Kriging model. To obtain the data for the Kriging model, the efficient global optimization technique is integrated with the NERS to extract the extreme time responses of the limit state function for any given system input. An adaptive response prediction and model maturation mechanism is developed based on mean square error (MSE) to concurrently improve the accuracy and computational efficiency of the proposed approach. With the nested response surface of time, the time-variant reliability analysis can be converted into the time-independent reliability analysis and existing advanced reliability analysis methods can be used. Three case studies are used to demonstrate the efficiency and accuracy of NERS approach

  1. APPLICATION OF TRAVEL TIME RELIABILITY FOR PERFORMANCE ORIENTED OPERATIONAL PLANNING OF EXPRESSWAYS

    Science.gov (United States)

    Mehran, Babak; Nakamura, Hideki

    Evaluation of impacts of congestion improvement scheme s on travel time reliability is very significant for road authorities since travel time reliability repr esents operational performance of expressway segments. In this paper, a methodology is presented to estimate travel tim e reliability prior to implementation of congestion relief schemes based on travel time variation modeling as a function of demand, capacity, weather conditions and road accident s. For subject expressway segmen ts, traffic conditions are modeled over a whole year considering demand and capacity as random variables. Patterns of demand and capacity are generated for each five minute interval by appl ying Monte-Carlo simulation technique, and accidents are randomly generated based on a model that links acci dent rate to traffic conditions. A whole year analysis is performed by comparing de mand and available capacity for each scenario and queue length is estimated through shockwave analysis for each time in terval. Travel times are estimated from refined speed-flow relationships developed for intercity expressways and buffer time index is estimated consequently as a measure of travel time reliability. For validation, estimated reliability indices are compared with measured values from empirical data, and it is shown that the proposed method is suitable for operational evaluation and planning purposes.

  2. Reliability issues and solutions for coding social communication performance in classroom settings.

    Science.gov (United States)

    Olswang, Lesley B; Svensson, Liselotte; Coggins, Truman E; Beilinson, Jill S; Donaldson, Amy L

    2006-10-01

    To explore the utility of time-interval analysis for documenting the reliability of coding social communication performance of children in classroom settings. Of particular interest was finding a method for determining whether independent observers could reliably judge both occurrence and duration of ongoing behavioral dimensions for describing social communication performance. Four coders participated in this study. They observed and independently coded 6 social communication behavioral dimensions using handheld computers. The dimensions were mutually exclusive and accounted for all verbal and nonverbal productions during a specified time frame. The technology allowed for coding frequency and duration for each entered code. Data were collected from 20 different 2-min video segments of children in kindergarten through 3rd-grade classrooms. Data were analyzed for interobserver and intraobserver agreements using time-interval sorting and Cohen's kappa. Further, interval size and total observation length were manipulated to determine their influence on reliability. The data revealed interval sorting and kappa to be a suitable method for examining reliability of occurrence and duration of ongoing social communication behavioral dimensions. Nearly all comparisons yielded medium to large kappa values; interval size and length of observation minimally affected results. Implications The analysis procedure described in this research solves a challenge in reliability: comparing coding by independent observers of both occurrence and duration of behaviors. Results indicate the utility of a new coding taxonomy and technology for application in online observations of social communication in a classroom setting.

  3. Advanced control rooms and crew performance issues: Implications for human reliability

    International Nuclear Information System (INIS)

    O'Hara, J.M.; Hall, R.E.

    1991-01-01

    Recent trends in advanced control room (ACR) design are considered with respect to their impact on human performance. It is concluded that potentially negative influences exist, however, a variety of factors make it difficult to model, analyze, and quantify these effects for human reliability analyses (HRAs)

  4. Methodology for performing RF reliability experiments on a generic test structure

    NARCIS (Netherlands)

    Sasse, G.T.; de Vries, Rein J.; Schmitz, Jurriaan

    2007-01-01

    This paper discusses a new technique developed for generating well defined RF large voltage swing signals for on wafer experiments. This technique can be employed for performing a broad range of different RF reliability experiments on one generic test structure. The frequency dependence of a

  5. Influence of test reliability on the screening performance of frequency-doubling perimetry

    NARCIS (Netherlands)

    Heeg, GP; Jansonius, NM

    PURPOSE: To investigate the influence of test reliability on the screening performance of frequency,doubling perimetry (FDT). DESIGN: Cross-sectional study. METHODS: FDT sensitivity and specificity were calculated three times using three different strategies for handling unreliable (that is, > 0

  6. Reliability assessment of serviceability performance of braced retaining walls using a neural network approach

    Science.gov (United States)

    Goh, A. T. C.; Kulhawy, F. H.

    2005-05-01

    In urban environments, one major concern with deep excavations in soft clay is the potentially large ground deformations in and around the excavation. Excessive movements can damage adjacent buildings and utilities. There are many uncertainties associated with the calculation of the ultimate or serviceability performance of a braced excavation system. These include the variabilities of the loadings, geotechnical soil properties, and engineering and geometrical properties of the wall. A risk-based approach to serviceability performance failure is necessary to incorporate systematically the uncertainties associated with the various design parameters. This paper demonstrates the use of an integrated neural network-reliability method to assess the risk of serviceability failure through the calculation of the reliability index. By first performing a series of parametric studies using the finite element method and then approximating the non-linear limit state surface (the boundary separating the safe and failure domains) through a neural network model, the reliability index can be determined with the aid of a spreadsheet. Two illustrative examples are presented to show how the serviceability performance for braced excavation problems can be assessed using the reliability index.

  7. A method to evaluate performance reliability of individual subjects in laboratory research applied to work settings.

    Science.gov (United States)

    1978-10-01

    This report presents a method that may be used to evaluate the reliability of performance of individual subjects, particularly in applied laboratory research. The method is based on analysis of variance of a tasks-by-subjects data matrix, with all sc...

  8. The Effect of Instrument-Specific Rater Training on Interrater Reliability and Counseling Skills Performance Differentiation

    Science.gov (United States)

    Meacham, Paul Douglas, Jr.

    2013-01-01

    The purpose of this study was to explore the effect of instrument-specific rater training on interrater reliability (IRR) and counseling skills performance differentiation. Strong IRR is of primary concern to effective program evaluation (McCullough, Kuhn, Andrews, Valen, Hatch, & Osimo, 2003; Schanche, Nielsen, McCullough, Valen, &…

  9. Feasibility and Inter-Rater Reliability of Physical Performance Measures in Acutely Admitted Older Medical Patients

    DEFF Research Database (Denmark)

    Bodilsen, Ann Christine; Juul-Larsen, Helle Gybel; Petersen, Janne

    2015-01-01

    OBJECTIVE: Physical performance measures can be used to predict functional decline and increased dependency in older persons. However, few studies have assessed the feasibility or reliability of such measures in hospitalized older patients. Here we assessed the feasibility and inter-rater reliabi......OBJECTIVE: Physical performance measures can be used to predict functional decline and increased dependency in older persons. However, few studies have assessed the feasibility or reliability of such measures in hospitalized older patients. Here we assessed the feasibility and inter......-rater reliability of four simple measures of physical performance in acutely admitted older medical patients. DESIGN: During the first 24 hours of hospitalization, the following were assessed twice by different raters in 52 (≥ 65 years) patients admitted for acute medical illness: isometric hand grip strength, 4......, and 30-s chair stand were 8%, 7%, and 18%, and the SRD95% values were 22%, 17%, and 49%. CONCLUSION: In acutely admitted older medical patients, grip strength, gait speed, and the Cumulated Ambulation Score measurements were feasible and showed high inter-rater reliability when administered by different...

  10. Evidence of Reliability and Validity for a Children’s Auditory Continuous Performance Test

    Directory of Open Access Journals (Sweden)

    Michael J. Lasee

    2013-11-01

    Full Text Available Continuous Performance Tests (CPTs are commonly utilized clinical measures of attention and response inhibition. While there have been many studies of CPTs that utilize a visual format, there is considerably less research employing auditory CPTs. The current study provides initial reliability and validity evidence for the Auditory Vigilance Screening Measure (AVSM, a newly developed CPT. Participants included 105 five- to nine-year-old children selected from two rural Midwestern school districts. Reliability data for the AVSM was collected through retesting of 42 participants. Validity was evaluated through correlation of AVSM scales with subscales from the ADHD Rating Scale–IV. Test–retest reliability coefficients ranged from .62 to .74 for AVSM subscales. A significant (r = .31 correlation was obtained between the AVSM Impulsivity Scale and teacher ratings of inattention. Limitations and implications for future study are discussed.

  11. Assessing the Impact of Clothing and Individual Equipment (CIE) on Soldier Physical, Biomechanical, and Cognitive Performance Part 1: Test Methodology

    Science.gov (United States)

    2018-02-01

    29 during Soldier Equipment Configuration Impact on Performance: Establishing a Test Methodology for the...during ACSM’S resource manual for exercise testing and prescription Human Movement Science, 31(2), Proceedings of the 2016 American Biomechanics...Performance of Medium Rucksack Prototypes An investigation: Comparison of live-fire and weapon simulator test methodologies and the of three extremity armor

  12. Different Approaches for Ensuring Performance/Reliability of Plastic Encapsulated Microcircuits (PEMs) in Space Applications

    Science.gov (United States)

    Gerke, R. David; Sandor, Mike; Agarwal, Shri; Moor, Andrew F.; Cooper, Kim A.

    2000-01-01

    Engineers within the commercial and aerospace industries are using trade-off and risk analysis to aid in reducing spacecraft system cost while increasing performance and maintaining high reliability. In many cases, Commercial Off-The-Shelf (COTS) components, which include Plastic Encapsulated Microcircuits (PEMs), are candidate packaging technologies for spacecrafts due to their lower cost, lower weight and enhanced functionality. Establishing and implementing a parts program that effectively and reliably makes use of these potentially less reliable, but state-of-the-art devices, has become a significant portion of the job for the parts engineer. Assembling a reliable high performance electronic system, which includes COTS components, requires that the end user assume a risk. To minimize the risk involved, companies have developed methodologies by which they use accelerated stress testing to assess the product and reduce the risk involved to the total system. Currently, there are no industry standard procedures for accomplishing this risk mitigation. This paper will present the approaches for reducing the risk of using PEMs devices in space flight systems as developed by two independent Laboratories. The JPL procedure involves primarily a tailored screening with accelerated stress philosophy while the APL procedure is primarily, a lot qualification procedure. Both Laboratories successfully have reduced the risk of using the particular devices for their respective systems and mission requirements.

  13. The prone bridge test: Performance, validity, and reliability among older and younger adults.

    Science.gov (United States)

    Bohannon, Richard W; Steffl, Michal; Glenney, Susan S; Green, Michelle; Cashwell, Leah; Prajerova, Kveta; Bunn, Jennifer

    2018-04-01

    The prone bridge maneuver, or plank, has been viewed as a potential alternative to curl-ups for assessing trunk muscle performance. The purpose of this study was to assess prone bridge test performance, validity, and reliability among younger and older adults. Sixty younger (20-35 years old) and 60 older (60-79 years old) participants completed this study. Groups were evenly divided by sex. Participants completed surveys regarding physical activity and abdominal exercise participation. Height, weight, body mass index (BMI), and waist circumference were measured. On two occasions, 5-9 days apart, participants held a prone bridge until volitional exhaustion or until repeated technique failure. Validity was examined using data from the first session: convergent validity by calculating correlations between survey responses, anthropometrics, and prone bridge time, known groups validity by using an ANOVA comparing bridge times of younger and older adults and of men and women. Test-retest reliability was examined by using a paired t-test to compare prone bridge times for Session1 and Session 2. Furthermore, an intraclass correlation coefficient (ICC) was used to characterize relative reliability and minimal detectable change (MDC 95% ) was used to describe absolute reliability. The mean prone bridge time was 145.3 ± 71.5 s, and was positively correlated with physical activity participation (p ≤ 0.001) and negatively correlated with BMI and waist circumference (p ≤ 0.003). Younger participants had significantly longer plank times than older participants (p = 0.003). The ICC between testing sessions was 0.915. The prone bridge test is a valid and reliable measure for evaluating abdominal performance in both younger and older adults. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. A Regulatory Perspective on the Performance and Reliability of Nuclear Passive Safety Systems

    International Nuclear Information System (INIS)

    Quan, Pham Trung; Lee, Sukho

    2016-01-01

    Passive safety systems have been proven to enhance the safety of NPPs. When an accident such as station blackout occurs, these systems can perform the following functions: the decay heat removal, passive safety injection, containment cooling, and the retention of radioactive materials. Following the IAEA definitions, using passive safety systems reduces reliance on active components to achieve proper actuation and not requiring operator intervention in accident conditions. That leads to the deviations in boundary conditions of the critical process or geometric parameters, which activate and operate the system to perform accident prevention and mitigation functions. The main difficulties in evaluation of functional failure of passive systems arise because of (a) lack of plant operational experience; (b) scarcity of adequate experimental data from integral test facilities or from separate effect tests in order to understand the performance characteristics of these passive systems, not only at normal operation but also during accidents and transients; (c) lack of accepted definitions of failure modes for these systems; and (d) difficulty in modeling certain physical behavior of these systems. Reliability assessment of the PSS is still one of the important issues. Several reliability methodologies such as REPAS, RMPS and ASPRA have been applied to the reliability assessments. However, some issues are remained unresolved due to lack of understanding of the treatment of dynamic failure characteristics of components of the PSS, the treatment of dynamic variation of independence process parameters such as ambient temperature and the functional failure criteria of the PSS. Dynamic reliability methodologies should be integrated in the PSS reliability analysis to have a true estimate of system failure probability. The methodology should estimate the physical variation of the parameters and the frequency of the accident sequences when the dynamic effects are considered

  15. RELIABILITY OF ANKLE-FOOT MORPHOLOGY, MOBILITY, STRENGTH, AND MOTOR PERFORMANCE MEASURES.

    Science.gov (United States)

    Fraser, John J; Koldenhoven, Rachel M; Saliba, Susan A; Hertel, Jay

    2017-12-01

    Assessment of foot posture, morphology, intersegmental mobility, strength and motor control of the ankle-foot complex are commonly used clinically, but measurement properties of many assessments are unclear. To determine test-retest and inter-rater reliability, standard error of measurement, and minimal detectable change of morphology, joint excursion and play, strength, and motor control of the ankle-foot complex. Reliability study. 24 healthy, recreationally-active young adults without history of ankle-foot injury were assessed by two clinicians on two occasions, three to ten days apart. Measurement properties were assessed for foot morphology (foot posture index, total and truncated length, width, arch height), joint excursion (weight-bearing dorsiflexion, rearfoot and hallux goniometry, forefoot inclinometry, 1 st metatarsal displacement) and joint play, strength (handheld dynamometry), and motor control rating during intrinsic foot muscle (IFM) exercises. Clinician order was randomized using a Latin Square. The clinicians performed independent examinations and did not confer on the findings for the duration of the study. Test-retest and inter-tester reliability and agreement was assessed using intraclass correlation coefficients (ICC 2,k ) and weighted kappa ( K w ). Test-retest reliability ICC were as follows: morphology: .80-1.00, joint excursion: .58-.97, joint play: -.67-.84, strength: .67-.92, IFM motor rating: K W -.01-.71. Inter-rater reliability ICC were as follows: morphology: .81-1.00, joint excursion: .32-.97, joint play: -1.06-1.00, strength: .53-.90, and IFM motor rating: K w .02-.56. Measures of ankle-foot posture, morphology, joint excursion, and strength demonstrated fair to excellent test-retest and inter-rater reliability. Test-retest reliability for rating of perceived difficulty and motor performance was good to excellent for short-foot, toe-spread-out, and hallux exercises and poor to fair for lesser toe extension. Joint play measures had

  16. Performance Analysis of a Solar Dryer Equipped with a Recycling Air System and Desiccant Chamber

    Directory of Open Access Journals (Sweden)

    M.H Aghkhani

    2013-09-01

    Full Text Available Drying is a high energy consuming process. Solar drying is one of the most popular methods for dehydration of agricultural products. In the present study, the performance of a forced convection solar dryer equipped with recycling air system and desiccant chamber was investigated. The solar dryer is comprised of solar collector, drying chamber, silica jell desiccant chamber, air ducts, fan and measuring and controlling system. Drying rate and energy consumption in three levels of air temperature (40, 45 and 50 oC and two modes of drying (with recycling air and no-recycling with open duct system were measured and compared. The results showed that increasing the drying air temperature decreased the drying time and increased the energy consumption in the mode of non-recycling air system. The dryer efficiency and drying rate were better in the mode of recycling air system than open duct system. The highest dryer efficiency was obtained from drying air temperature of 50 oC and the mode of recycling air system. In general, the efficiency of solar collector and the highest efficiency of the dryer were 0.34 and 0.41, respectively.

  17. Equipment performance and radiation protection status in X-ray fluoroscopy units in Sudan

    International Nuclear Information System (INIS)

    Ahmed, N. A.; Nayl, A. I.; Suliman, I. I.

    2012-01-01

    The number of fluoroscopy and fluoroscopically guided procedures has been substantially growing in developing countries at the same time advanced and sophisticated equipment are used in some hospitals. However, radiation protection requirements are not necessarily well adopted. In this study nine fluoroscopy X-ray units in Sudan were examined for compliance with international standards. The tests included: beam quality, entrance surface air kerma, image quality and radiation field measurements. Staff radiation protection tools such as lead aprons and eye glasses were also visually examined to find out whether international recommendations were fulfilled and to determine the level of staff awareness. The measured peak tube voltage deviation exceeded the recommended tolerance level in 30 % of the measurements. The results of patient doses measurements exceeded the recommended reference dose levels in 43 % of the measurements; however image quality and radiation field generally fulfilled the requirements for most units. The study revealed that a considerable number of fluoroscopy units were not performing according to the international standards and highlights the need of optimisation of radiation protection. (authors)

  18. Impact of nuclear fuel performance and reliability in a deregulated electricity market

    International Nuclear Information System (INIS)

    Barnoski, M.; Kaiser, B.

    1997-01-01

    US nuclear plants are now placing a great deal of importance on fuel performance and reliability because of their direct effect on a plant's capacity factor, availability, operating flexibility, outage duration, and worker exposure. This is reflected by utilities making fuel reliability a principal vendor evaluation criterion and making fuel performance an important bonus/penalty provision. Defect-free fuel, combined with ever improving design features, makes it possible for plants to operate at higher outputs while reducing operating and maintenance costs. Higher electrical output at lower cost is essential for US nuclear plants to meet the expected competition in a deregulated market. Through continued investment in manufacturing improvements and a vigilant, systematic design process, ABB's nuclear fuel has contributed to helping its nuclear utility customers reduce their cost of doing business. (author) 1 fig., 1 tab

  19. Country-wide quality control of equipment in Norwegian laboratories performing in vivo nuclear medicine examinations

    International Nuclear Information System (INIS)

    Skretting, A.; Rootwelt, K.; Berthelsen, T.

    1984-01-01

    The report presents the methods used and the results obtained in quality control tests performd in all Norwegian hospital laboratories performing in vivo nuclear medicine examinations. The tests included activity meters and scintillation cameras. The activity meters were tested by means of calibrated, long-lived radioactive sources. The quality of these instruments were judged to be satisfactory for moderate and high activities, non of them showing a deviation of more than 10% from the calibration value. Deviations were larger at low activities and were for some laboratories unacceptable. The scintillation cameras test included studies of flood field (homogeneity), geometrical resolution and energy resolution, as well as measurements of count rate characteristics and sensitivity. 40% of the cameras were judged to have flood field responses with satisfactory homogeneity, whereas 32% of the cameras had a satisfactory resolution ability. A liver/abdomen phantom test was carried out by the staff of the actual laboratory. This test proved that only 20% of the laboratories had a satisfactory total performance, managing to detect and describe satisfactorily 4 out of 5 simulated defects in the liver phantom. Lack of information density and insufficient number of projections was the main reason for unsatisfactory results with good cameras. It is recommended that quality control equipment as used in the described tests should be made available to Norwegian hospitals for self assessment. Regular quality assurance tests as recommended by the Norwegian Association for Radiation Physics and Norwegian Society of Nuclear Medicine should be implemented in all hospitals. Moreover, a practical training course in quality assurance should be arranged. (RF)

  20. Performance management in the internal supply chain of an industry of equipment for refrigeration

    Directory of Open Access Journals (Sweden)

    Emílio Della Bruna Junior

    2013-05-01

    Full Text Available Supply chains are complex, conflicting and uncertain management environments, where the best alternatives are usually not previously know, they need to be built based on the managers objectives. For this reason, its decision-makers have been looking for management tools that expand their understanding in order to identify which objectives best represent their values regarding the decision context. With this in mind, this paper aims to develop a Performance Evaluation Model for the operations of the internal supply chain of an organization of the refrigeration equipment sector. The study adopts a mixture of qualitative and quantitative approaches and applies them through a case study. The data collection was conducted through unstructured interviews with the decision-maker as well as specialists appointed by him and supplemented by documentary research. The applied intervention instrument is the Multricriteria Decision Aid – Constructivist (MCDA-C due to its capacity of expanding the knowledge in the decision-maker about the consequences of his decisions on the criteria that he deems critical to the success of the company. One of the results of this research was the identification of the objectives that, according to the decision-maker perception, should drive the alternative definition process, as well as their organization, ordinal and cardinal measurement and integration. In addition, it can be highlighted the current situation diagnosis and elaboration of improvement actions, where the implementation effects of the Lean Philosophy and an Advanced Planning System are evaluated. The main contributions made by the article resides in the proposal of solutions for fulfilling gaps identified within the Supply Chain Performance Evaluation area and in the application of the MCDA-C to a real case.

  1. The performance investigation of a temperature cascaded cogeneration system equipped with adsorption desalination unit

    KAUST Repository

    Myat, Aung

    2013-02-01

    This paper presents the performance investigation of a temperature cascaded cogeneration plant, shortly in TCCP, equipped with an efficient waste heat recovery system. The TCCP or cogeneration system produces four types of useful energy namely (i) electricity, (ii) steam, (iii) cooling, and (iv) dehumidification and distilled water by utilizing single energy source. The TCCP comprises a Capstone C30 micro-turbine that generates nominal capacity of 26 kW of electricity, a compact and efficient waste heat recovery system and a host of waste heatactivated devices namely (i) a steam generator, (ii) an absorption chiller, (iii) an adsorption desalination system, and (iv) a multi-bed desiccant dehumidifier. The analysis is performed under different operation conditions such as heat source temperatures, flow rates of heat transfer fluids and chilled water inlet temperatures. The only single heat source for TCCP is obtained from exhaust gas of micro-turbine and it is channeled to a series of waste heat recovery heat exchangers to steam and hot water at different temperatures. Hot water produced by such a compact heat exchangers is the driving heat source to produce steam of 15 kg/h, cooling of 2 Rton, dehumidification of 2 Rton, and distilled water of 0.7 m3/day. A set of experiments, both part load and full load, of micro-turbine is conducted to examine the electricity generation and the exhaust gas temperature. It is observed that energy utilization factor could achieve as high as 70% while fuel energy saving ratio is found to be 28%. © 2013 Desalination Publications. All rights reserved.

  2. The performance investigation of a temperature cascaded cogeneration system equipped with adsorption desalination unit

    KAUST Repository

    Myat, Aung; Thu, Kyaw; Kim, Youngdeuk; Ng, K. C.

    2013-01-01

    This paper presents the performance investigation of a temperature cascaded cogeneration plant, shortly in TCCP, equipped with an efficient waste heat recovery system. The TCCP or cogeneration system produces four types of useful energy namely (i) electricity, (ii) steam, (iii) cooling, and (iv) dehumidification and distilled water by utilizing single energy source. The TCCP comprises a Capstone C30 micro-turbine that generates nominal capacity of 26 kW of electricity, a compact and efficient waste heat recovery system and a host of waste heatactivated devices namely (i) a steam generator, (ii) an absorption chiller, (iii) an adsorption desalination system, and (iv) a multi-bed desiccant dehumidifier. The analysis is performed under different operation conditions such as heat source temperatures, flow rates of heat transfer fluids and chilled water inlet temperatures. The only single heat source for TCCP is obtained from exhaust gas of micro-turbine and it is channeled to a series of waste heat recovery heat exchangers to steam and hot water at different temperatures. Hot water produced by such a compact heat exchangers is the driving heat source to produce steam of 15 kg/h, cooling of 2 Rton, dehumidification of 2 Rton, and distilled water of 0.7 m3/day. A set of experiments, both part load and full load, of micro-turbine is conducted to examine the electricity generation and the exhaust gas temperature. It is observed that energy utilization factor could achieve as high as 70% while fuel energy saving ratio is found to be 28%. © 2013 Desalination Publications. All rights reserved.

  3. Approach to reliability assessment

    International Nuclear Information System (INIS)

    Green, A.E.; Bourne, A.J.

    1975-01-01

    Experience has shown that reliability assessments can play an important role in the early design and subsequent operation of technological systems where reliability is at a premium. The approaches to and techniques for such assessments, which have been outlined in the paper, have been successfully applied in variety of applications ranging from individual equipments to large and complex systems. The general approach involves the logical and systematic establishment of the purpose, performance requirements and reliability criteria of systems. This is followed by an appraisal of likely system achievment based on the understanding of different types of variational behavior. A fundamental reliability model emerges from the correlation between the appropriate Q and H functions for performance requirement and achievement. This model may cover the complete spectrum of performance behavior in all the system dimensions

  4. Performance and reliability of the Y-Balance TestTM in high school athletes.

    Science.gov (United States)

    Smith, Laura J; Creps, James R; Bean, Ryan; Rodda, Becky; Alsalaheen, Bara

    2017-11-07

    Lower extremity injuries account for 32.9% of the overall injuries in high school athletes. Previous research has suggested that asymmetry greater than 4cm using the Y-Balance TestTM Lower Quarter (YBT-LQ) in the anterior direction is predictive of non- contact injuries in adults and collegiate athletes. The prevalence of asymmetries or abnormal YBT-LQ performance is not well documented for adolescents. The primary purposes of this study are: 1) to characterize the prevalence of YBT-LQ asymmetries and performance in a cross-sectional sample of adolescents, 2) to examine possible differences in performance on the YBT-LQ between male and female adolescents, and 3) to describe the test-retest reliability of the YBT-LQ in a subsample of adolescents. Observational cross-sectional study. High-school athletes completed the YBT-LQ as main outcome measure. 51 male, 59 female high-school athletes participated in this study. Asymmetries greater than 4cm in the posteromedial (PM) reach direction were most prevalent for male (54.9%) and female (50.8%) participants. Females presented with slightly higher composite scores. Good reliability (ICC = 0.89) was found for the anterior (ANT) direction, and moderate reliability with 0.76 for posterolateral (PL) and 0.63 for PM directions. The MDC95 for the ANT direction was 6% and 12% for both the PL and PM directions. The YBT-LQ performance can be beneficial in assessing recovery in an injured extremity compared to the other limb. However, due to the large MDC95, noted in the PM and PL directions, the differences between sequential testing cannot be attributed to true change in balance unless they exceed the MDC95. In this study, 79% of the athletes presented with at least one asymmetry in YBT-LQ reach distances. Moderate reliability in the PL and PM directions warrants reexamination of the definition of asymmetry in these directions.

  5. The performance shaping factors influence analysis on the human reliability for NPP operation

    International Nuclear Information System (INIS)

    Farcasiu, M.; Nitoi, M.; Apostol, M.; Florescu, G.

    2008-01-01

    The Human Reliability Analysis (HRA) is an important step in Probabilistic Safety Assessment (PSA) studies and offers an advisability for concrete improvement of the man - machine - organization interfaces, reliability and safety. The goals of this analysis are to obtain sufficient details in order to understand and document all-important factors that affect human performance. The purpose of this paper is to estimate the human errors probabilities in view of the negative or positive effect of the human performance shaping factors (PSFs) for the mitigation of the initiating events which could occur in Nuclear Power Plant (NPP). Using THERP and SPAR-H methods, an analysis model of PSFs influence on the human reliability is performed. This model is applied to more important activities, that are necessary to mitigate 'one steam generator tube failure' event at Cernavoda NPP. The results are joint human error probabilities (JHEP) values estimated for the following situations: without regarding to PSFs influence; with PSFs in specific conditions; with PSFs which could have only positive influence and with PSFs which could have only negative influence. In addition, PSFs with negative influence were identified and using the DOE method, the necessary activities for changing negative influence were assigned. (authors)

  6. Reliability assessment of stress concentration performance state for a perforated composite plate under traction

    Directory of Open Access Journals (Sweden)

    Jabbouri A.

    2012-07-01

    Full Text Available Considering a perforated sandwich plate made from two elastic homogenous and isotropic layers, and having a square hole, reliability assessment of stress concentration limit state for which the stress should not exceed a given threshold is performed in this work. Assuming that the plate dimensions and the applied loading are deterministic, focus is done on the square hole centre position and edge length considered to be random variables. The means and the standard deviations of these variables are assumed to be known, but no information is so far available about their densities of probabilities. To assess reliability of the performance state, reliability analysis known methods are applied to a response surface representation of the stress concentration factor of the perforated plate which is obtained through quadratic polynomial regression of finite element results. A parametric study is performed regarding the influence of the distributions of probabilities chosen to model the hole dimensions uncertainties. It is shown that the probability of failure depends largely on the selected densities of probabilities.

  7. Study on Performance Shaping Factors (PSFs) Quantification Method in Human Reliability Analysis (HRA)

    International Nuclear Information System (INIS)

    Kim, Ar Ryum; Jang, Inseok Jang; Seong, Poong Hyun; Park, Jinkyun; Kim, Jong Hyun

    2015-01-01

    The purpose of HRA implementation is 1) to achieve the human factor engineering (HFE) design goal of providing operator interfaces that will minimize personnel errors and 2) to conduct an integrated activity to support probabilistic risk assessment (PRA). For these purposes, various HRA methods have been developed such as technique for human error rate prediction (THERP), simplified plant analysis risk human reliability assessment (SPAR-H), cognitive reliability and error analysis method (CREAM) and so on. In performing HRA, such conditions that influence human performances have been represented via several context factors called performance shaping factors (PSFs). PSFs are aspects of the human's individual characteristics, environment, organization, or task that specifically decrements or improves human performance, thus respectively increasing or decreasing the likelihood of human errors. Most HRA methods evaluate the weightings of PSFs by expert judgment and explicit guidance for evaluating the weighting is not provided. It has been widely known that the performance of the human operator is one of the critical factors to determine the safe operation of NPPs. HRA methods have been developed to identify the possibility and mechanism of human errors. In performing HRA methods, the effect of PSFs which may increase or decrease human error should be investigated. However, the effect of PSFs were estimated by expert judgment so far. Accordingly, in order to estimate the effect of PSFs objectively, the quantitative framework to estimate PSFs by using PSF profiles is introduced in this paper

  8. Performance of intraclass correlation coefficient (ICC) as a reliability index under various distributions in scale reliability studies.

    Science.gov (United States)

    Mehta, Shraddha; Bastero-Caballero, Rowena F; Sun, Yijun; Zhu, Ray; Murphy, Diane K; Hardas, Bhushan; Koch, Gary

    2018-04-29

    Many published scale validation studies determine inter-rater reliability using the intra-class correlation coefficient (ICC). However, the use of this statistic must consider its advantages, limitations, and applicability. This paper evaluates how interaction of subject distribution, sample size, and levels of rater disagreement affects ICC and provides an approach for obtaining relevant ICC estimates under suboptimal conditions. Simulation results suggest that for a fixed number of subjects, ICC from the convex distribution is smaller than ICC for the uniform distribution, which in turn is smaller than ICC for the concave distribution. The variance component estimates also show that the dissimilarity of ICC among distributions is attributed to the study design (ie, distribution of subjects) component of subject variability and not the scale quality component of rater error variability. The dependency of ICC on the distribution of subjects makes it difficult to compare results across reliability studies. Hence, it is proposed that reliability studies should be designed using a uniform distribution of subjects because of the standardization it provides for representing objective disagreement. In the absence of uniform distribution, a sampling method is proposed to reduce the non-uniformity. In addition, as expected, high levels of disagreement result in low ICC, and when the type of distribution is fixed, any increase in the number of subjects beyond a moderately large specification such as n = 80 does not have a major impact on ICC. Copyright © 2018 John Wiley & Sons, Ltd.

  9. Improvement of the electromagnetic situation in networks of operational current at nuclear power plant for the purpose of ensuring reliability of monitoring systems, control, RPA and communications, realized on the basis of digital equipment

    International Nuclear Information System (INIS)

    Fomenko, O.V.; Moloshnaya, E.S.; Ul'yanova, Yu.E.

    2014-01-01

    The authors propose the technique of designing a portable grounding contour for protection and control systems, relay protection and automation (RPA) systems made on the basis of digital equipment in networks of an operational direct current to increase the reliability of their functioning under the conditions of influence of strong hindrances and improvement of an electromagnetic environment [ru

  10. Development of a valid and reliable test to assess trauma radiograph interpretation performance

    International Nuclear Information System (INIS)

    Neep, M.J.; Steffens, T.; Riley, V.; Eastgate, P.; McPhail, S.M.

    2017-01-01

    Objectives: The purpose of this investigation was to develop and examine the preliminary validity and reliability among radiographers of a test to assess trauma radiograph interpretation performance suitable for use among health professionals. Methods: Stage 1 examined 14,159 consecutive appendicular and axial examinations from a hospital emergency department over a 12 month period to quantify a typical anatomical region case-mix of trauma radiographs. A sample of radiographic cases representative of affected anatomical regions was then developed into the Image Interpretation Test (IIT). Stage 2 involved prospective investigations of the IIT's reliability (inter-rater, intra-rater, internal consistency) and validity (concurrent) among 41 radiographers. Results: The IIT included 60 cases. The median (interquartile range) clinical experience of participants was 5 (2–10) years. Case scores were internally consistent (Cronbach's alpha = 0.90). Favourable inter-rater reliability (kappa > 0.70 for 58/60 cases, Intra-class correlation coefficient (ICC) > 0.99 for total score) and intra-rater reliability (kappa > 0.90 for 60/60 cases, ICC > 0.99 for total score) was observed. There was a positive association between radiographers' confidence in image interpretation and IIT score (coefficient = 1.52, r-squared = 0.60, p < 0.001). Conclusions: The IIT developed during this investigation included a selection of radiographic cases consistent with anatomical regions represented in an adult trauma case-mix. This study has also provided foundational preliminary evidence to support the reliability and validity of the IIT among radiographers. The findings suggest that it is possible to assess image interpretation performance of adult trauma radiographs with this test. - Highlights: • Development of an Image Interpretation Test (IIT). • Cases consistent with anatomical regions represented in a typical adult trauma case-mix. • Development of a

  11. Reliability- and performance-based robust design optimization of MEMS structures considering technological uncertainties

    Science.gov (United States)

    Martowicz, Adam; Uhl, Tadeusz

    2012-10-01

    The paper discusses the applicability of a reliability- and performance-based multi-criteria robust design optimization technique for micro-electromechanical systems, considering their technological uncertainties. Nowadays, micro-devices are commonly applied systems, especially in the automotive industry, taking advantage of utilizing both the mechanical structure and electronic control circuit on one board. Their frequent use motivates the elaboration of virtual prototyping tools that can be applied in design optimization with the introduction of technological uncertainties and reliability. The authors present a procedure for the optimization of micro-devices, which is based on the theory of reliability-based robust design optimization. This takes into consideration the performance of a micro-device and its reliability assessed by means of uncertainty analysis. The procedure assumes that, for each checked design configuration, the assessment of uncertainty propagation is performed with the meta-modeling technique. The described procedure is illustrated with an example of the optimization carried out for a finite element model of a micro-mirror. The multi-physics approach allowed the introduction of several physical phenomena to correctly model the electrostatic actuation and the squeezing effect present between electrodes. The optimization was preceded by sensitivity analysis to establish the design and uncertain domains. The genetic algorithms fulfilled the defined optimization task effectively. The best discovered individuals are characterized by a minimized value of the multi-criteria objective function, simultaneously satisfying the constraint on material strength. The restriction of the maximum equivalent stresses was introduced with the conditionally formulated objective function with a penalty component. The yielded results were successfully verified with a global uniform search through the input design domain.

  12. Impact of scaling on the performance and reliability degradation of metal-contacts in NEMS devices

    KAUST Repository

    Dadgour, Hamed F.

    2011-04-01

    Nano-electro-mechanical switches (NEMS) offer new possibilities for the design of ultra energy-efficient systems; however, thus far, all the fabricated NEMS devices require high supply voltages that limit their applicability for logic designs. Therefore, research is being conducted to lower the operating voltages by scaling down the physical dimensions of these devices. However, the impact of device scaling on the electrical and mechanical properties of metal contacts in NEMS devices has not been thoroughly investigated in the literature. Such a study is essential because metal contacts play a critical role in determining the overall performance and reliability of NEMS. Therefore, the comprehensive analytical study presented in this paper highlights the performance and reliability degradations of such metal contacts caused by scaling. The proposed modeling environment accurately takes into account the impact of roughness of contact surfaces, elastic/plastic deformation of contacting asperities, and various inter-molecular forces between mating surfaces (such as Van der Waals and capillary forces). The modeling results are validated and calibrated using available measurement data. This scaling analysis indicates that the key contact properties of gold contacts (resistance, stiction and wear-out) deteriorate "exponentially" with scaling. Simulation results demonstrate that reliable (stiction-free) operation of very small contact areas (≈ 6nm x 6nm) will be a daunting task due to the existence of strong surface forces. Hence, contact degradation is identified as a major problem to the scaling of NEMS transistors. © 2011 IEEE.

  13. Practical application of the benchmarking technique to increase reliability and efficiency of power installations and main heat-mechanic equipment of thermal power plants

    Science.gov (United States)

    Rimov, A. A.; Chukanova, T. I.; Trofimov, Yu. V.

    2016-12-01

    Data on the comparative analysis variants of the quality of power installations (benchmarking) applied in the power industry is systematized. It is shown that the most efficient variant of implementation of the benchmarking technique is the analysis of statistical distributions of the indicators in the composed homogenous group of the uniform power installations. The benchmarking technique aimed at revealing the available reserves on improvement of the reliability and heat efficiency indicators of the power installations of the thermal power plants is developed in the furtherance of this approach. The technique provides a possibility of reliable comparison of the quality of the power installations in their homogenous group limited by the number and adoption of the adequate decision on improving some or other technical characteristics of this power installation. The technique provides structuring of the list of the comparison indicators and internal factors affecting them represented according to the requirements of the sectoral standards and taking into account the price formation characteristics in the Russian power industry. The mentioned structuring ensures traceability of the reasons of deviation of the internal influencing factors from the specified values. The starting point for further detail analysis of the delay of the certain power installation indicators from the best practice expressed in the specific money equivalent is positioning of this power installation on distribution of the key indicator being a convolution of the comparison indicators. The distribution of the key indicator is simulated by the Monte-Carlo method after receiving the actual distributions of the comparison indicators: specific lost profit due to the short supply of electric energy and short delivery of power, specific cost of losses due to the nonoptimal expenditures for repairs, and specific cost of excess fuel equivalent consumption. The quality loss indicators are developed

  14. Good performance in Japan is proof of continuing safety and reliability improvement practice

    International Nuclear Information System (INIS)

    Sumi, Y.

    1987-01-01

    Nuclear power is a vital energy supply source for both security and economy for such countries as Japan whose sources of energy are dependent on imported materials. This is the very reason why Japan gives her national priority to the improvement of nuclear power safety and reliability. As of the end of 1986, total nuclear power capacity owned and operated by private utility companies in Japan amounted to 24521 MW with 32 units sharing -- 19% of the total generating capacity. Moreover, during 1986 these units scored a remarkably high capacity factor of 76.2% and shared almost 28% of the nationwide electric power production, thereby contributing to a considerable saving of imported sources of energy. This outstanding record has been achieved by the parties concerned who dedicated themselves to furthering nuclear plant safety and reliability improvement. In this connection, this paper summarizes those key factors contributing to the good nuclear power plant performance of the Kansai Electric Power Company

  15. Visual perspective in autobiographical memories: reliability, consistency, and relationship to objective memory performance.

    Science.gov (United States)

    Siedlecki, Karen L

    2015-01-01

    Visual perspective in autobiographical memories was examined in terms of reliability, consistency, and relationship to objective memory performance in a sample of 99 individuals. Autobiographical memories may be recalled from two visual perspectives--a field perspective in which individuals experience the memory through their own eyes, or an observer perspective in which individuals experience the memory from the viewpoint of an observer in which they can see themselves. Participants recalled nine word-cued memories that differed in emotional valence (positive, negative and neutral) and rated their memories on 18 scales. Results indicate that visual perspective was the most reliable memory characteristic overall and is consistently related to emotional intensity at the time of recall and amount of emotion experienced during the memory. Visual perspective is unrelated to memory for words, stories, abstract line drawings or faces.

  16. Thermal Performance and Reliability Characterization of Bonded Interface Materials (BIMs): Preprint

    Energy Technology Data Exchange (ETDEWEB)

    DeVoto, D.; Paret, P.; Mihalic, M.; Narumanchi, S.; Bar-Cohen, A.; Matin, K.

    2014-08-01

    Thermal interface materials are an important enabler for low thermal resistance and reliable electronics packaging for a wide array of applications. There is a trend towards bonded interface materials (BIMs) because of their potential for low thermal resistivity (< 1 mm2K/W). However, BIMs induce thermomechanical stresses in the package and can be prone to failures and integrity risks. Deteriorated interfaces can result in high thermal resistance in the package and degradation and/or failure of the electronics. DARPA's Thermal Management Technologies program has addressed this challenge, supporting the development of mechanically-compliant, low resistivity nano-thermal interface (NTI) materials. In this work, we describe the testing procedure and report the results of NREL's thermal performance and reliability characterization of an initial sample of four different NTI-BIMs.

  17. Performance evaluation of the quarter-scale Russian retrieval equipment for the removal of hazardous waste

    International Nuclear Information System (INIS)

    Enderlin, C.W.; Mullen, O.D.; Terrones, G.

    1997-09-01

    This report describes the test program for evaluating the Russian Retrieval Equipment fabricated by the Integrated Mining Chemical Company (IMCC) and delivered to the US by Radiochem Services Company (RCSC), both of Russia. The testing and fabrication of this equipment were sponsored by the US Department of Energy (DOE). The tests described in this report were conducted at the Pacific Northwest National Laboratory (PNNL) at the DOE Hanford Site by the Retrieval Process Development and Enhancement (RPD and E) team of the Tank Focus Area program (TFA). Tests were carried out jointly by Russian and US personnel for the purpose of evaluating the Russian Retrieval Equipment for potential deployment within the DOE complex. Section 1.0 of this report presents the objectives and a brief background for the test program. The Russian Equipment is described in Section 2.0. Section 3.0 describes the approach taken for testing the equipment. The results of the tests and an analysis of the data are described in Section 4.0. The results and observations obtained from the tests are discussed in Section 5.0. Recommendations and conclusions are presented in Section 6.0

  18. "Do-It-Yourself" reliable pH-stat device by using open-source software, inexpensive hardware and available laboratory equipment

    Science.gov (United States)

    Kragic, Rastislav; Kostic, Mirjana

    2018-01-01

    In this paper, we present the construction of a reliable and inexpensive pH stat device, by using open-source “OpenPhControl” software, inexpensive hardware (a peristaltic and a syringe pump, Arduino, a step motor…), readily available laboratory devices: a pH meter, a computer, a webcam, and some 3D printed parts. We provide a methodology for the design, development and test results of each part of the device, as well as of the entire system. In addition to dosing reagents by means of a low-cost peristaltic pump, we also present carefully controlled dosing of reagents by an open-source syringe pump. The upgrading of the basic open-source syringe pump is given in terms of pump control and application of a larger syringe. In addition to the basic functions of pH stat, i.e. pH value measurement and maintenance, an improvement allowing the device to be used for potentiometric titration has been made as well. We have demonstrated the device’s utility when applied for cellulose fibers oxidation with 2,2,6,6-tetramethylpiperidine-1-oxyl radical, i.e. for TEMPO-mediated oxidation. In support of this, we present the results obtained for the oxidation kinetics, the consumption of added reagent and experimental repeatability. Considering that the open-source scientific tools are available to everyone, and that researchers can construct and adjust the device according to their needs, as well as, that the total cost of the open-source pH stat device, excluding the existing laboratory equipment (pH meter, computer and glossary) was less than 150 EUR, we believe that, at a small fraction of the cost of available commercial offers, our open-source pH stat can significantly improve experimental work where the use of pH stat is necessary. PMID:29509793

  19. "Do-It-Yourself" reliable pH-stat device by using open-source software, inexpensive hardware and available laboratory equipment.

    Science.gov (United States)

    Milanovic, Jovana Z; Milanovic, Predrag; Kragic, Rastislav; Kostic, Mirjana

    2018-01-01

    In this paper, we present the construction of a reliable and inexpensive pH stat device, by using open-source "OpenPhControl" software, inexpensive hardware (a peristaltic and a syringe pump, Arduino, a step motor…), readily available laboratory devices: a pH meter, a computer, a webcam, and some 3D printed parts. We provide a methodology for the design, development and test results of each part of the device, as well as of the entire system. In addition to dosing reagents by means of a low-cost peristaltic pump, we also present carefully controlled dosing of reagents by an open-source syringe pump. The upgrading of the basic open-source syringe pump is given in terms of pump control and application of a larger syringe. In addition to the basic functions of pH stat, i.e. pH value measurement and maintenance, an improvement allowing the device to be used for potentiometric titration has been made as well. We have demonstrated the device's utility when applied for cellulose fibers oxidation with 2,2,6,6-tetramethylpiperidine-1-oxyl radical, i.e. for TEMPO-mediated oxidation. In support of this, we present the results obtained for the oxidation kinetics, the consumption of added reagent and experimental repeatability. Considering that the open-source scientific tools are available to everyone, and that researchers can construct and adjust the device according to their needs, as well as, that the total cost of the open-source pH stat device, excluding the existing laboratory equipment (pH meter, computer and glossary) was less than 150 EUR, we believe that, at a small fraction of the cost of available commercial offers, our open-source pH stat can significantly improve experimental work where the use of pH stat is necessary.

  20. MAPPS (Maintenance Personnel Performance Simulation): a computer simulation model for human reliability analysis

    International Nuclear Information System (INIS)

    Knee, H.E.; Haas, P.M.

    1985-01-01

    A computer model has been developed, sensitivity tested, and evaluated capable of generating reliable estimates of human performance measures in the nuclear power plant (NPP) maintenance context. The model, entitled MAPPS (Maintenance Personnel Performance Simulation), is of the simulation type and is task-oriented. It addresses a number of person-machine, person-environment, and person-person variables and is capable of providing the user with a rich spectrum of important performance measures including mean time for successful task performance by a maintenance team and maintenance team probability of task success. These two measures are particularly important for input to probabilistic risk assessment (PRA) studies which were the primary impetus for the development of MAPPS. The simulation nature of the model along with its generous input parameters and output variables allows its usefulness to extend beyond its input to PRA

  1. The reliability and validity of a soccer-specific nonmotorised treadmill simulation (intermittent soccer performance test).

    Science.gov (United States)

    Aldous, Jeffrey W F; Akubat, Ibrahim; Chrismas, Bryna C R; Watkins, Samuel L; Mauger, Alexis R; Midgley, Adrian W; Abt, Grant; Taylor, Lee

    2014-07-01

    This study investigated the reliability and validity of a novel nonmotorised treadmill (NMT)-based soccer simulation using a novel activity category called a "variable run" to quantify fatigue during high-speed running. Twelve male University soccer players completed 3 familiarization sessions and 1 peak speed assessment before completing the intermittent soccer performance test (iSPT) twice. The 2 iSPTs were separated by 6-10 days. The total distance, sprint distance, and high-speed running distance (HSD) were 8,968 ± 430 m, 980 ± 75 m and 2,122 ± 140 m, respectively. No significant difference (p > 0.05) was found between repeated trials of the iSPT for all physiological and performance variables. Reliability measures between iSPT1 and iSPT2 showed good agreement (coefficient of variation: 0.80). Furthermore, the variable run phase showed HSD significantly decreased (p ≤ 0.05) in the last 15 minutes (89 ± 6 m) compared with the first 15 minutes (85 ± 7 m), quantifying decrements in high-speed exercise compared with the previous literature. This study validates the iSPT as a NMT-based soccer simulation compared with the previous match-play data and is a reliable tool for assessing and monitoring physiological and performance variables in soccer players. The iSPT could be used in a number of ways including player rehabilitation, understanding the efficacy of nutritional interventions, and also the quantification of environmentally mediated decrements on soccer-specific performance.

  2. An integrated methodology for the dynamic performance and reliability evaluation of fault-tolerant systems

    International Nuclear Information System (INIS)

    Dominguez-Garcia, Alejandro D.; Kassakian, John G.; Schindall, Joel E.; Zinchuk, Jeffrey J.

    2008-01-01

    We propose an integrated methodology for the reliability and dynamic performance analysis of fault-tolerant systems. This methodology uses a behavioral model of the system dynamics, similar to the ones used by control engineers to design the control system, but also incorporates artifacts to model the failure behavior of each component. These artifacts include component failure modes (and associated failure rates) and how those failure modes affect the dynamic behavior of the component. The methodology bases the system evaluation on the analysis of the dynamics of the different configurations the system can reach after component failures occur. For each of the possible system configurations, a performance evaluation of its dynamic behavior is carried out to check whether its properties, e.g., accuracy, overshoot, or settling time, which are called performance metrics, meet system requirements. Markov chains are used to model the stochastic process associated with the different configurations that a system can adopt when failures occur. This methodology not only enables an integrated framework for evaluating dynamic performance and reliability of fault-tolerant systems, but also enables a method for guiding the system design process, and further optimization. To illustrate the methodology, we present a case-study of a lateral-directional flight control system for a fighter aircraft

  3. Approach to the assessment of the performance of nondestructive test methods in the manufacture of nuclear power station equipment

    International Nuclear Information System (INIS)

    Michaut, J.P.

    1996-01-01

    The safety of a nuclear power station lies largely in the possibility of ensuring, at the time of in service inspections on major equipment, that the extent of faults which may appear or develop is not greater than that of faults detrimental to behavior in service. This assurance is based on performance demonstration of the nondestructive test methods used for inspecting the equipment in service. This is the subject of numerous studies in various countries. To ensure that manufacturing faults likely to downgrade the safety of the equipment are not discovered in service, it seems desirable to make sure that the performance of the nondestructive test (NDT) methods which are going to be used in manufacture will be at least as high as those used in service and that they are therefore capable of guaranteeing detection of faults clearly less important than really harmful faults. The performance of NDT methods and their consistency with those which can be used in service is evaluated before the start of manufacture on a mock-up representative of the equipment itself. Information is given on research in progress on the bimetal welding of a pressurizer spray nozzle

  4. PERFORMANCE-RELIABILITY – THE MAIN SUBJECT OF THE BANKING ANALYSIS OF THE CREDITED SOCIETIES

    Directory of Open Access Journals (Sweden)

    AVRAM (BOITOŞ CAMELIA

    2013-12-01

    Full Text Available Since the crediting activity occupies the primary role in any banking institution, the necessity of study and its analysis is required by following some steps both at a microeconomic level and at a macroeconomic one. Going over the theme, which aims at the importance of a thorough study of the clients' reliability for highlighting the existing risks in the banking activity in general, and particularly in the crediting activity, becomes as more interesting as their approach at the level of the member states of the European Union tends towards a common theme. Starting from these premises, we have considered as being extremely important the selection of a research theme which aims at the risks in the crediting activity, emphasizing the analysis of the clients' reliability both in the decision of crediting in order to assume the risk of credit and in determining the financial and banking performances. Being given the complexity of the existing risks in the banking activity in general and particularly of the credit risk, the clients' reliability represents an extremely important field, of research and application, bearing in mind both the actual stage of developing the Romanian banking system and the attempts of its alignment to the requirements imposed by the European Union.

  5. Design for High Performance, Low Power, and Reliable 3D Integrated Circuits

    CERN Document Server

    Lim, Sung Kyu

    2013-01-01

    This book describes the design of through-silicon-via (TSV) based three-dimensional integrated circuits.  It includes details of numerous “manufacturing-ready” GDSII-level layouts of TSV-based 3D ICs, developed with tools covered in the book. Readers will benefit from the sign-off level analysis of timing, power, signal integrity, and thermo-mechanical reliability for 3D IC designs.  Coverage also includes various design-for-manufacturability (DFM), design-for-reliability (DFR), and design-for-testability (DFT) techniques that are considered critical to the 3D IC design process. Describes design issues and solutions for high performance and low power 3D ICs, such as the pros/cons of regular and irregular placement of TSVs, Steiner routing, buffer insertion, low power 3D clock routing, power delivery network design and clock design for pre-bond testability. Discusses topics in design-for-electrical-reliability for 3D ICs, such as TSV-to-TSV coupling, current crowding at the wire-to-TSV junction and the e...

  6. 30 CFR 75.1909 - Nonpermissible diesel-powered equipment; design and performance requirements.

    Science.gov (United States)

    2010-07-01

    ... energy, or leakage; (4) Releases only by a manual control that does not operate any other equipment...; and (xi) A water separator and fuel filter(s) must be provided. (4) A sensor to monitor the..., and accelerator pedals, controls which are of automobile orientation; (4) An audible warning device...

  7. Microgrid Design Analysis Using Technology Management Optimization and the Performance Reliability Model

    Energy Technology Data Exchange (ETDEWEB)

    Stamp, Jason E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Eddy, John P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jensen, Richard P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Munoz-Ramos, Karina [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    Microgrids are a focus of localized energy production that support resiliency, security, local con- trol, and increased access to renewable resources (among other potential benefits). The Smart Power Infrastructure Demonstration for Energy Reliability and Security (SPIDERS) Joint Capa- bility Technology Demonstration (JCTD) program between the Department of Defense (DOD), Department of Energy (DOE), and Department of Homeland Security (DHS) resulted in the pre- liminary design and deployment of three microgrids at military installations. This paper is focused on the analysis process and supporting software used to determine optimal designs for energy surety microgrids (ESMs) in the SPIDERS project. There are two key pieces of software, an ex- isting software application developed by Sandia National Laboratories (SNL) called Technology Management Optimization (TMO) and a new simulation developed for SPIDERS called the per- formance reliability model (PRM). TMO is a decision support tool that performs multi-objective optimization over a mixed discrete/continuous search space for which the performance measures are unrestricted in form. The PRM is able to statistically quantify the performance and reliability of a microgrid operating in islanded mode (disconnected from any utility power source). Together, these two software applications were used as part of the ESM process to generate the preliminary designs presented by SNL-led DOE team to the DOD. Acknowledgements Sandia National Laboratories and the SPIDERS technical team would like to acknowledge the following for help in the project: * Mike Hightower, who has been the key driving force for Energy Surety Microgrids * Juan Torres and Abbas Akhil, who developed the concept of microgrids for military instal- lations * Merrill Smith, U.S. Department of Energy SPIDERS Program Manager * Ross Roley and Rich Trundy from U.S. Pacific Command * Bill Waugaman and Bill Beary from U.S. Northern Command * Tarek Abdallah, Melanie

  8. Developing of Individual Instrument Performance Anxiety Scale: ValidityReliability Study

    Directory of Open Access Journals (Sweden)

    Esra DALKIRAN

    2016-07-01

    Full Text Available In this study, it is intended to develop a scale unique to our culture, concerning individual instrument performance anxiety of the students who are getting instrument training in the Department of Music Education. In the study, the descriptive research model is used and qualitative research techniques are utilized. The study population consists of the students attending the 23 universities which has Music Education Department. The sample of the study consists of 438 girls and 312 boys, totally 750 students who are studying in the Department of Music Education of randomly selected 10 universities. As a result of the explanatory and confirmatory factor analyses that were performed, a onedimensional structure consisting of 14 items was obtained. Also, t-scores and the coefficient scores of total item correlation concerning the distinguishing power of the items, the difference in the scores of the set of lower and upper 27% was calculated, and it was observed that the items are distinguishing as a result of both analyses. Of the scale, Cronbach's alpha coefficient of internal consistency was calculated as .94, and test-retest reliability coefficient was calculated as .93. As a result, a valid and reliable assessment and evaluation instrument that measures the exam performance anxiety of the students studying in the Department of Music Education, has been developed.

  9. Performance and Reliability of Bonded Interfaces for High-temperature Packaging: Annual Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    DeVoto, Douglas J. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-10-19

    As maximum device temperatures approach 200 °Celsius, continuous operation, sintered silver materials promise to maintain bonds at these high temperatures without excessive degradation rates. A detailed characterization of the thermal performance and reliability of sintered silver materials and processes has been initiated for the next year. Future steps in crack modeling include efforts to simulate crack propagation directly using the extended finite element method (X-FEM), a numerical technique that uses the partition of unity method for modeling discontinuities such as cracks in a system.

  10. Performance and Reliability of Bonded Interfaces for High-Temperature Packaging (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Devoto, D.

    2014-11-01

    The thermal performance and reliability of sintered-silver is being evaluated for power electronics packaging applications. This will be experimentally accomplished by the synthesis of large-area bonded interfaces between metalized substrates that will be subsequently subjected to thermal cycles. A finite element model of crack initiation and propagation in these bonded interfaces will allow for the interpretation of degradation rates by a crack-velocity (V)-stress intensity factor (K) analysis. The experiment is outlined, and the modeling approach is discussed.

  11. Reliability and effect of sodium bicarbonate: buffering and 2000-m rowing performance.

    Science.gov (United States)

    Carr, Amelia J; Slater, Gary J; Gore, Christopher J; Dawson, Brian; Burke, Louise M

    2012-06-01

    The aim of this study was to determine the effect and reliability of acute and chronic sodium bicarbonate ingestion for 2000-m rowing ergometer performance (watts) and blood bicarbonate concentration [HCO3-]. In a crossover study, 7 well-trained rowers performed paired 2000-m rowing ergometer trials under 3 double-blinded conditions: (1) 0.3 grams per kilogram of body mass (g/kg BM) acute bicarbonate; (2) 0.5 g/kg BM daily chronic bicarbonate for 3 d; and (3) calcium carbonate placebo, in semi-counterbalanced order. For 2000-m performance and [HCO3-], we examined differences in effects between conditions via pairwise comparisons, with differences interpreted in relation to the likelihood of exceeding smallest worthwhile change thresholds for each variable. We also calculated the within-subject variation (percent typical error). There were only trivial differences in 2000-m performance between placebo (277 ± 60 W), acute bicarbonate (280 ± 65 W) and chronic bicarbonate (282 ± 65 W); however, [HCO3-] was substantially greater after acute bicarbonate, than with chronic loading and placebo. Typical error for 2000-m mean power was 2.1% (90% confidence interval 1.4 to 4.0%) for acute bicarbonate, 3.6% (2.5 to 7.0%) for chronic bicarbonate, and 1.6% (1.1 to 3.0%) for placebo. Postsupplementation [HCO3-] typical error was 7.3% (5.0 to 14.5%) for acute bicarbonate, 2.9% (2.0 to 5.7%) for chronic bicarbonate and 6.0% (1.4 to 11.9%) for placebo. Performance in 2000-m rowing ergometer trials may not substantially improve after acute or chronic bicarbonate loading. However, performances will be reliable with both acute and chronic bicarbonate loading protocols.

  12. Human reliability under sleep deprivation: Derivation of performance shaping factor multipliers from empirical data

    International Nuclear Information System (INIS)

    Griffith, Candice D.; Mahadevan, Sankaran

    2015-01-01

    This paper develops a probabilistic approach that could use empirical data to derive values of performance shaping factor (PSF) multipliers for use in quantitative human reliability analysis (HRA). The proposed approach is illustrated with data on sleep deprivation effects on performance. A review of existing HRA methods reveals that sleep deprivation is not explicitly included at present, and expert opinion is frequently used to inform HRA model multipliers. In this paper, quantitative data from empirical studies regarding the effect of continuous hours of wakefulness on performance measures (reaction time, accuracy, and number of lapses) are used to develop a method to derive PSF multiplier values for sleep deprivation, in the context of the SPAR-H model. Data is extracted from the identified studies according to the meta-analysis research synthesis method and used to investigate performance trends and error probabilities. The error probabilities in test and control conditions are compared, and the resulting probability ratios are suggested for use in informing the selection of PSF multipliers in HRA methods. Although illustrated for sleep deprivation, the proposed methodology is general, and can be applied to other performance shaping factors. - Highlights: • Method proposed to derive performance shaping factor multipliers from empirical data. • Studies reporting the effect of sleep deprivation on performance are analyzed. • Test data using psychomotor vigilance tasks are analyzed. • Error probability multipliers computed for reaction time, lapses, and accuracy measures.

  13. Perform qualify reliability-power tests by shooting common mistakes: practical problems and standard answers per Telcordia/Bellcore requests

    Science.gov (United States)

    Yu, Zheng

    2002-08-01

    Facing the new demands of the optical fiber communications market, almost all the performance and reliability of optical network system are dependent on the qualification of the fiber optics components. So, how to comply with the system requirements, the Telcordia / Bellcore reliability and high-power testing has become the key issue for the fiber optics components manufacturers. The qualification of Telcordia / Bellcore reliability or high-power testing is a crucial issue for the manufacturers. It is relating to who is the outstanding one in the intense competition market. These testing also need maintenances and optimizations. Now, work on the reliability and high-power testing have become the new demands in the market. The way is needed to get the 'Triple-Win' goal expected by the component-makers, the reliability-testers and the system-users. To those who are meeting practical problems for the testing, there are following seven topics that deal with how to shoot the common mistakes to perform qualify reliability and high-power testing: ¸ Qualification maintenance requirements for the reliability testing ¸ Lots control for preparing the reliability testing ¸ Sampling select per the reliability testing ¸ Interim measurements during the reliability testing ¸ Basic referencing factors relating to the high-power testing ¸ Necessity of re-qualification testing for the changing of producing ¸ Understanding the similarity for product family by the definitions

  14. A maturidade e o desempenho das equipes no ambiente produtivo Maturity and performance of teams in the production environment

    Directory of Open Access Journals (Sweden)

    Robson Luiz Montanari

    2011-01-01

    Full Text Available O presente estudo teve como objetivo identificar a influência da maturidade das equipes no desempenho das suas atividades. Para tanto, sete equipes de uma prestadora de serviços foram analisadas. Os procedimentos metodológicos foram permeados por entrevistas, observações não participantes, aplicação de dois questionários e três instrumentos. Os resultados permitiram identificar influências da maturidade no desempenho das equipes em ambiente produtivo, bem como verificar que ela está intimamente relacionada ao comportamento revelado no desempenho dentro do grupo. Nas equipes com maior maturidade, comportamentos indesejáveis ao desempenho coletivo não apareceram na mesma proporção aos das equipes com menor grau de maturidade. Infere-se que, à medida que a maturidade dos grupos é aumentada, pela presença de integrantes mais comprometidos e com confiança mútua, os membros das equipes mudam o comportamento alterando a forma de funcionamento do grupo e transformando-se em uma equipe. Se as equipes em estudo, dentro de uma sequência evolutiva de funcionamento, aumentarem sua maturidade, tendem a influenciar positivamente o seu desempenho no ambiente produtivo em que estão inseridas.This study aimed to identify the influence of maturity of the teams in carrying out its activities. Seven teams of a service provider industry were analyzed. The data were collected through interviews, non-participant observations, application of two questionnaires and three instruments. The results showed the influence of maturity on the performance of teams in the production environment and that it is closely related to the individual behavior within the group. In the teams with more maturity, the presence of undesirable collective behaviors did not occur in the same proportion of that of teams with lesser degrees of maturity. It can be inferred that as the maturity of the groups is increased by the presence of more committed members with mutual

  15. Rehabilitation of heat exchange equipment a key to power plant life extension and performance improvement

    Energy Technology Data Exchange (ETDEWEB)

    Taveau, F.; Huiban, A.M. [Alstom Power Heat Exchange, 78 - Velizy Villacoublay (France)

    2001-07-01

    With the current evolutions of the energy market and the life extension of the power plants, all the equipment initially supplied need one day or another partial or total rehabilitation. For heat exchange equipment, this includes the condensers, feed water heaters and various heat exchangers. Modernization is in particular necessary when in-service monitoring and periodic inspections show significant deteriorations of the tubes and cooling water leakages leading to forced outages or when tube and tube plate materials are no longer suited to cooling water characteristics or to updated specifications of the secondary system. Feedwater heaters and heat exchangers damaged by erosion/corrosion, vibrations, etc. can be re-designed, manufactured and replaced easily. The operation is more complex on condensers and requires technical surveys, study of alternative solutions and has a more direct impact on the global output of the power plant. That is why our conference will focus on the condenser refurbishment. (author)

  16. Rehabilitation of heat exchange equipment a key to power plant life extension and performance improvement

    International Nuclear Information System (INIS)

    Taveau, F.; Huiban, A.M.

    2001-01-01

    With the current evolutions of the energy market and the life extension of the power plants, all the equipment initially supplied need one day or another partial or total rehabilitation. For heat exchange equipment, this includes the condensers, feed water heaters and various heat exchangers. Modernization is in particular necessary when in-service monitoring and periodic inspections show significant deteriorations of the tubes and cooling water leakages leading to forced outages or when tube and tube plate materials are no longer suited to cooling water characteristics or to updated specifications of the secondary system. Feedwater heaters and heat exchangers damaged by erosion/corrosion, vibrations, etc. can be re-designed, manufactured and replaced easily. The operation is more complex on condensers and requires technical surveys, study of alternative solutions and has a more direct impact on the global output of the power plant. That is why our conference will focus on the condenser refurbishment. (author)

  17. Accuracy and Reliability in the Prediction of End-of-Life Performance of Solar Generators

    Science.gov (United States)

    Rapp, Etienne

    2008-09-01

    The end-of-life power analysis of solar arrays is calculated using a combination of arithmetic and root square sums of loss factors. These loss factors are sometimes linked to degradations, sometimes linked to uncertainties. The uncertainties of the degradations are taken into account considering contractual "worst cases". This paper will put the first stones for a move "metrological" evaluation of the probable performance associated with a standard uncertainty. The turn from silicon to triple junction solar cells induces some changes in the degradation parameters of solar arrays: * The triple junction cells are more sensitive to UV darkening than silicon ones. * The cell voltage is higher and the current is lower. Then the cell strings are shorter, and there are more strings in parallel. This induces some changes in the reliability analyses and risk management. * The failure modes and failure rates of these cells have to be compared and discussed. We try to define improved rules to design solar arrays for end of life performance, for a better knowledge of the margins and a better reliability.

  18. A Correlated Model for Evaluating Performance and Energy of Cloud System Given System Reliability

    Directory of Open Access Journals (Sweden)

    Hongli Zhang

    2015-01-01

    Full Text Available The serious issue of energy consumption for high performance computing systems has attracted much attention. Performance and energy-saving have become important measures of a computing system. In the cloud computing environment, the systems usually allocate various resources (such as CPU, Memory, Storage, etc. on multiple virtual machines (VMs for executing tasks. Therefore, the problem of resource allocation for running VMs should have significant influence on both system performance and energy consumption. For different processor utilizations assigned to the VM, there exists the tradeoff between energy consumption and task completion time when a given task is executed by the VMs. Moreover, the hardware failure, software failure and restoration characteristics also have obvious influences on overall performance and energy. In this paper, a correlated model is built to analyze both performance and energy in the VM execution environment given the reliability restriction, and an optimization model is presented to derive the most effective solution of processor utilization for the VM. Then, the tradeoff between energy-saving and task completion time is studied and balanced when the VMs execute given tasks. Numerical examples are illustrated to build the performance-energy correlated model and evaluate the expected values of task completion time and consumed energy.

  19. Measures of small business success/performance: Importance, reliability and usability

    Directory of Open Access Journals (Sweden)

    Leković Božidar

    2015-01-01

    Full Text Available The main objective of this paper is to assess the reliability of selected measures of success/performance of small enterprises taking into account all the advantages and disadvantages of objective (traditional, financial and subjective (personal perception indicators. The realization of the basic objective will enable removal of doubt in different categories of success / performance of small businesses, which would be a secondary objective of the paper. The research methodology involves the use parametric procedures due to the characteristics of the selected variables and the number of observations in the sample. Univariate ANOVA and Pearson's coefficient correlation will be the main methods used. The basis of this study consists of data gathered from e-survey of 260 entrepreneurs/ owners/ managers of small enterprises in administrative sub-region of the Republic of Serbia. The analysis results show the correlation between subjective estimate of success of owners/ entrepreneurs/ managers and objective performance indicators, which can be characterized as complementary, meaning that subjective assessment as well as formally stated performance indicators are realistic. In addition, it is important to emphasize as an important result within the group of objective performance indicators, the differences between two groups, financial and non-financial, performance indicators.

  20. Standardization of heparins by means of high performance liquid chromatography equipped with a low angle laser light scattering detector

    NARCIS (Netherlands)

    Hennink, W.E.; van den Berg, J.W.A.; Feijen, Jan

    1987-01-01

    This study shows that HPLC-LALLS (high performance liquid chromatography with a light-scattering detector) is a convenient and reliable method for the characterization of standard heparin samples, provided that polyelectrolyte artefacts are suppressed by a suitable dialysis procedure. The method has

  1. The tendency of medical electrical equipment - IEC 60601-2-54: Particular requirements for the basic safety and essential performance of x-ray equipment for radiography and radioscopy

    International Nuclear Information System (INIS)

    Roh, Young Hoon; Kim, Jung Min

    2015-01-01

    Medical electrical equipment - Part 1: General requirement for basic safety and essential performance of MFDS was revised as 3th edition and Medical electrical equipment Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment will be expected to be announced as notification. Therefore this technical report was written to introduce provision of the particular requirements, replacement, addition, amendment. The purpose of this particular requirements is to secure requirements for basic safety and essential performance of X-ray equipment for radiography and radioscopy. X-ray high voltage generator, mechanical protective device, protection against radiation is included in this particular requirements. Medical electrical equipment - Part 1, Part 1-2, Part 1-3 is applied to this particular requirements. If the requirements is announced as notification, It is expected to widen understanding for basic safety and essential performance of X-ray equipment for radiography and radioscopy and play a part to internationalize of medical equipment

  2. Influence of performance improvement of AP1000 nuclear island main equipment forging on manufacturing

    International Nuclear Information System (INIS)

    Liu Zhiying

    2013-01-01

    In order to comply with the 60-year design life of an AP1000 nuclear power station, higher strength and ductility requirements have been made on AP1000 nuclear island SG forgings than on CPR1000 nuclear island main equipment. In addition, bigger size of AP1000 nuclear island SG forgings increases the difficulty of manufacturing them. Insufficient recognition of these changes may cause unstable quality of forgings and possible quality problems in follow-up welding procedure. On the basis of comparison and analysis of AP1000 nuclear island SG forgings and CPR1000 nuclear island forgings, this thesis suggests clear directions for the actions we need to take. (author)

  3. The cognitive environment simulation as a tool for modeling human performance and reliability

    International Nuclear Information System (INIS)

    Woods, D.D.; Pople, H. Jr.; Roth, E.M.

    1990-01-01

    The US Nuclear Regulatory Commission is sponsoring a research program to develop improved methods to model the cognitive behavior of nuclear power plant (NPP) personnel. Under this program, a tool for simulating how people form intentions to act in NPP emergency situations was developed using artificial intelligence (AI) techniques. This tool is called Cognitive Environment Simulation (CES). The Cognitive Reliability Assessment Technique (or CREATE) was also developed to specify how CBS can be used to enhance the measurement of the human contribution to risk in probabilistic risk assessment (PRA) studies. The next step in the research program was to evaluate the modeling tool and the method for using the tool for Human Reliability Analysis (HRA) in PRAs. Three evaluation activities were conducted. First, a panel of highly distinguished experts in cognitive modeling, AI, PRA and HRA provided a technical review of the simulation development work. Second, based on panel recommendations, CES was exercised on a family of steam generator tube rupture incidents where empirical data on operator performance already existed. Third, a workshop with HRA practitioners was held to analyze a worked example of the CREATE method to evaluate the role of CES/CREATE in HRA. The results of all three evaluations indicate that CES/CREATE represents a promising approach to modeling operator intention formation during emergency operations

  4. Embedded Sensors and Controls to Improve Component Performance and Reliability: Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Kisner, Roger A [ORNL; Melin, Alexander M [ORNL; Burress, Timothy A [ORNL; Fugate, David L [ORNL; Holcomb, David Eugene [ORNL; Wilgen, John B [ORNL; Miller, John M [ORNL; Wilson, Dane F [ORNL; Silva, Pamela C [ORNL; Whitlow, Lynsie J [ORNL; Peretz, Fred J [ORNL

    2012-10-01

    The overall project objective is to demonstrate improved reliability and increased performance made possible by deeply embedding instrumentation and controls (I&C) in nuclear power plant components. The project is employing a highly instrumented canned rotor, magnetic bearing, fluoride salt pump as its I&C technology demonstration vehicle. The project s focus is not primarily on pump design, but instead is on methods to deeply embed I&C within a pump system. However, because the I&C is intimately part of the basic millisecond-by-millisecond functioning of the pump, the I&C design cannot proceed in isolation from the other aspects of the pump. The pump will not function if the characteristics of the I&C are not embedded within the design because the I&C enables performance of the basic function rather than merely monitoring quasi-stable performance. Traditionally, I&C has been incorporated in nuclear power plant (NPP) components after their design is nearly complete; adequate performance was obtained through over-design. This report describes the progress and status of the project and provides a conceptual design overview for the embedded I&C pump.

  5. Simulation-based Assessment to Reliably Identify Key Resident Performance Attributes.

    Science.gov (United States)

    Blum, Richard H; Muret-Wagstaff, Sharon L; Boulet, John R; Cooper, Jeffrey B; Petrusa, Emil R; Baker, Keith H; Davidyuk, Galina; Dearden, Jennifer L; Feinstein, David M; Jones, Stephanie B; Kimball, William R; Mitchell, John D; Nadelberg, Robert L; Wiser, Sarah H; Albrecht, Meredith A; Anastasi, Amanda K; Bose, Ruma R; Chang, Laura Y; Culley, Deborah J; Fisher, Lauren J; Grover, Meera; Klainer, Suzanne B; Kveraga, Rikante; Martel, Jeffrey P; McKenna, Shannon S; Minehart, Rebecca D; Mitchell, John D; Mountjoy, Jeremi R; Pawlowski, John B; Pilon, Robert N; Shook, Douglas C; Silver, David A; Warfield, Carol A; Zaleski, Katherine L

    2018-04-01

    Obtaining reliable and valid information on resident performance is critical to patient safety and training program improvement. The goals were to characterize important anesthesia resident performance gaps that are not typically evaluated, and to further validate scores from a multiscenario simulation-based assessment. Seven high-fidelity scenarios reflecting core anesthesiology skills were administered to 51 first-year residents (CA-1s) and 16 third-year residents (CA-3s) from three residency programs. Twenty trained attending anesthesiologists rated resident performances using a seven-point behaviorally anchored rating scale for five domains: (1) formulate a clear plan, (2) modify the plan under changing conditions, (3) communicate effectively, (4) identify performance improvement opportunities, and (5) recognize limits. A second rater assessed 10% of encounters. Scores and variances for each domain, each scenario, and the total were compared. Low domain ratings (1, 2) were examined in detail. Interrater agreement was 0.76; reliability of the seven-scenario assessment was r = 0.70. CA-3s had a significantly higher average total score (4.9 ± 1.1 vs. 4.6 ± 1.1, P = 0.01, effect size = 0.33). CA-3s significantly outscored CA-1s for five of seven scenarios and domains 1, 2, and 3. CA-1s had a significantly higher proportion of worrisome ratings than CA-3s (chi-square = 24.1, P < 0.01, effect size = 1.50). Ninety-eight percent of residents rated the simulations more educational than an average day in the operating room. Sensitivity of the assessment to CA-1 versus CA-3 performance differences for most scenarios and domains supports validity. No differences, by experience level, were detected for two domains associated with reflective practice. Smaller score variances for CA-3s likely reflect a training effect; however, worrisome performance scores for both CA-1s and CA-3s suggest room for improvement.

  6. NDE performance demonstration in the US nuclear power industry - applications, costs, lessons learned, and connection to NDE reliability

    International Nuclear Information System (INIS)

    Ammirato, F.

    1997-01-01

    Periodic inservice inspection (ISI) of nuclear power plant components is performed in the United States to satisfy legal commitments and to provide plant owners with reliable information for managing degradation. Performance demonstration provides credible evidence that ISI will fulfill its objectives. This paper examines the technical requirements for inspection and discusses how these technical needs are used to develop effective performance demonstration applications. NDE reliability is discussed with particular reference to its role in structural integrity assessments and its connection with performance demonstration. It is shown that the role of NDE reliability can range from very small to critical depending on the particular application and must be considered carefully in design of inspection techniques and performance demonstration programs used to qualify the inspection. Finally, the costs, benefits, and problems associated with performance demonstration are reviewed along with lessons learned from more than 15 years of performance demonstration experience in the US. (orig.)

  7. Backup control airstart performance on a digital electronic engine control-equipped F100-engine

    Science.gov (United States)

    Johnson, J. B.

    1984-01-01

    The air start capability of a backup control (BUC) was tested for a digital electronic engine control (DEEC) equipped F100 engine, which was installed in an F-15 aircraft. Two air start schedules were tested. Using the group 1 start schedule, based on a 40 sec timer, an air speed of 300 knots was required to ensure successful 40 and 25% BUC mode spooldown airstarts. If core rotor speed (N2) was less than 40% a stall would occur when the start bleed closed, 40 sec after initiation of the air start. All jet fuel starter (JFS) assisted air starts were successful with the group 1 start schedule. For the group 2 schedule, the time between pressurization and start bleed closure ranged between 50 sec and 72 sec. Idle rps was lower than the desired 65% for air starts at higher altitudes and lower air speeds.

  8. The Mirror Fusion Test Facility cryogenic system: Performance, management approach, and present equipment status

    International Nuclear Information System (INIS)

    Slack, D.S.; Chronis, W.C.

    1987-01-01

    The cryogenic system for the Mirror Fusion Test Facility (MFTF) is a 14-kW, 4.35-K helium refrigeration system that proved to be highly successful and cost-effective. All operating objectives were met, while remaining within a few percent of initial cost and schedule plans. The management approach used in MFTF allowed decisions to be made quickly and effectively, and it helped keep costs down. Manpower levels, extent and type of industrial participation, key aspects of subcontractor specifications, and subcontractor interactions are reviewed, as well as highlights of the system tests, operation, and present equipment status. Organizations planning large, high-technology systems may benefit from this experience with the MFTF cryogenic system

  9. The experiences to improve plant performance and reliability of Ko-Ri nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ho Weon [Korea Electric Power Corp. Ko-Ri nuclear power division, Ko-Ri (Korea, Republic of)

    1998-07-01

    This paper provides a discussion of the lessons learned from operational experience and the future plans to improve performance of the Ko-Ri plant. To operate nuclear power plants safely with good performance is the only way to mitigate the negative image of nuclear power generation to the public and to enhance the economical benefit compared to other electrical generation method. Therefore, in a continuous effort to overcome a negative challenge from outside, we have driven an aggressive 'OCTF' campaign as part of safety. As a result of our efforts, the following remarkable achievements have been accomplished. (1) 3 times of OCTF during recent three years (2) Selected twice as a top notch power plant on the list of NEI magazine in terms of plant capacity factor (3) No scram recorded in 1997 for all 4 units at Ko-Ri site. Ko-Ri is now undergoing the large scale plant betterment projects for retaking-off our operating performance to the level of new challenge target. Such improvement of critical components in the reactor coolant system and turbine system greatly contribute to increase the safety and reliability of the plant and to shortening of the planned outage period as well as to reduction of radiation exposure and radwaste. (Cho, G. S.). 5 tabs., 10 figs.

  10. Modeling and Quantification of Team Performance in Human Reliability Analysis for Probabilistic Risk Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey C. JOe; Ronald L. Boring

    2014-06-01

    Probabilistic Risk Assessment (PRA) and Human Reliability Assessment (HRA) are important technical contributors to the United States (U.S.) Nuclear Regulatory Commission’s (NRC) risk-informed and performance based approach to regulating U.S. commercial nuclear activities. Furthermore, all currently operating commercial NPPs in the U.S. are required by federal regulation to be staffed with crews of operators. Yet, aspects of team performance are underspecified in most HRA methods that are widely used in the nuclear industry. There are a variety of "emergent" team cognition and teamwork errors (e.g., communication errors) that are 1) distinct from individual human errors, and 2) important to understand from a PRA perspective. The lack of robust models or quantification of team performance is an issue that affects the accuracy and validity of HRA methods and models, leading to significant uncertainty in estimating HEPs. This paper describes research that has the objective to model and quantify team dynamics and teamwork within NPP control room crews for risk informed applications, thereby improving the technical basis of HRA, which improves the risk-informed approach the NRC uses to regulate the U.S. commercial nuclear industry.

  11. The experiences to improve plant performance and reliability of Ko-Ri nuclear power plants

    International Nuclear Information System (INIS)

    Kang, Ho Weon

    1998-01-01

    This paper provides a discussion of the lessons learned from operational experience and the future plans to improve performance of the Ko-Ri plant. To operate nuclear power plants safely with good performance is the only way to mitigate the negative image of nuclear power generation to the public and to enhance the economical benefit compared to other electrical generation method. Therefore, in a continuous effort to overcome a negative challenge from outside, we have driven an aggressive 'OCTF' campaign as part of safety. As a result of our efforts, the following remarkable achievements have been accomplished. (1) 3 times of OCTF during recent three years (2) Selected twice as a top notch power plant on the list of NEI magazine in terms of plant capacity factor (3) No scram recorded in 1997 for all 4 units at Ko-Ri site. Ko-Ri is now undergoing the large scale plant betterment projects for retaking-off our operating performance to the level of new challenge target. Such improvement of critical components in the reactor coolant system and turbine system greatly contribute to increase the safety and reliability of the plant and to shortening of the planned outage period as well as to reduction of radiation exposure and radwaste. (Cho, G. S.). 5 tabs., 10 figs

  12. Assessing the Impact of Equipment Aging on System Performance Using Simulation Modeling Methods

    International Nuclear Information System (INIS)

    Gupta, N. K.

    2005-01-01

    The radiological Inductively Coupled Plasma Mass Spectrometer (ICP-MS) is used to analyze the radioactive samples collected from different radioactive material processing operations at Savannah River Site (SRS). The expeditious processing of these samples is important for safe and reliable operations at SRS. As the radiological (RAD) ICP-MS machine ages, the experience shows that replacement parts and repairs are difficult to obtain on time for reliable operations after 5 years of service. A discrete event model using commercial software EXTEND was prepared to assess the impact on sample turn around times as the ICP-MS gets older. The model was prepared using the sample statistics from the previous 4 years. Machine utilization rates were calculated for the new machine, 5 year old machine, 10 year old machine, and a 12 year old machine. Computer simulations were run for these periods and the sample delay times calculated. The model was validated against the sample statistics collected from the previous 4 quarters. 90% confidence intervals were calculated for the 10th, 25th, 50th, and 90th quantiles of the samples. The simulation results show that if 50% of the samples are needed on time for efficient site operations, a 10 year old machine could take nearly 50 days longer to process these samples than a 5-year old machine. This simulation effort quantifies the impact on sample turn around time as the ICP-MS gets older

  13. Radon removal equipment based on aeration: A literature study of tests performed in Sweden between 1981 and 1996

    International Nuclear Information System (INIS)

    Mjoenes, L.

    2000-02-01

    In Sweden some principles to reduce the radon concentration in drinking water were tested in the beginning of the 1980s. Spray aeration under atmospheric pressure, diffused bubble aeration, aeration in the pressure tank and different combinations of these principles were studied. Aeration in the drill hole and adsorption on granulated activated char-coal were also tested. The best results, about 70 % reduction, were obtained with aeration in the pressure tank with a spray system combined with diffused air bubbling. The Oerebro project in the beginning of the 1990s included on site testing of five different aeration solutions: Aeration in the drill hole, aeration in the storage tank, ejector aeration, shallow tray aeration and packed column aeration. The radon removal efficiency varied between 20 % and 99 %. In 1994 a study intended to test the radon removal capacity of different water treatment equipment was performed. Six units of radon separators were included but most of the tested equipment was installed for other water treatment purposes. The performed measurements showed that the only types of equipment that reduce the radon concentration efficiently are radon separators and reverse osmosis filters. The radon removal capacity of the radon separators varied between 23 % and 97 %. In 1996 the nine most common radon separators on the Swedish market were tested. The results showed that the tested radon removal equipment worked well, although the technical quality and chosen technical solutions were not always the best. The radon removal capacity of the units participating in this test was in most cases between 96 and 99 %. In some cases the capacity exceeded 99 %. In order to reach this radon removal capacity the water must be recirculated in a storage tank under atmospheric pressure

  14. Performance Test of the Salt transfer and Pellet fabrication of UCl{sub 3} Making Equipment for Electrorefining

    Energy Technology Data Exchange (ETDEWEB)

    Woo, M. S.; Jin, H. J.; Park, G. I.; Park, S. B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    The process to produce a uranium chloride salt includes two steps: a reaction process of gaseous chlorine with liquid cadmium to form the CdCl{sub 2} occurring in a Cd layer, followed by a process to produce UCl{sub 3} by the reaction of U in the LiCl-KCl eutectic salt and CdCl{sub 2}. Chemical reaction is next chlorination reaction; - Cd chlorination : Cd + Cl2 → CdCl{sub 2} - U chlorination : 3CdCl2 + 2U → 3Cd + 2UCl{sub 3} The apparatus for producing UCl{sub 3} consists of a chlorine gas generator, a uranium chlorinator, a Cd distiller, the pelletizer, a off-gas wet scrubber and a dry scrubber. Salt transfer system set among reactors to transfer salt at 500 .deg. C. The temperature of the reactants is maintained at about 600 .deg. C. After the reaction is completed in the uranium chlorinator, The Salt product is transferred to the Cd distiller to decrease residual Cd concentration in the salts, and then salt is transferred to the mould of pelletizer by a transfer system to fabricate pellet type salt. Performance test of the salt transfer and pellet fabrication of its equipment was tested in this work. Performance test of the salt transfer and pellet fabrication of UCl3 making equipment for Electrorefining carried out in this work. The result of equipment test is that melted salt at 600 .deg. C was easy transferred by salt transfer equipment heated at 500 .deg. C. In this time, salt transfer was carried out by argon gas pressurization at 3bar. When velocity of salt transfer was controlled under reduce pressure, velocity of salt transfer was difficult to control. And when salt pellet was fabricated by the mold of pelletizer heated at 90 .deg. C better than mold of pelletizer heated at 200 .deg. C because salt melted prevent leakage from mold of pelletizer.

  15. Radon removal equipment based on aeration: A literature study of tests performed in Sweden between 1981 and 1996

    Energy Technology Data Exchange (ETDEWEB)

    Mjoenes, L

    2000-02-01

    In Sweden some principles to reduce the radon concentration in drinking water were tested in the beginning of the 1980s. Spray aeration under atmospheric pressure, diffused bubble aeration, aeration in the pressure tank and different combinations of these principles were studied. Aeration in the drill hole and adsorption on granulated activated char-coal were also tested. The best results, about 70 % reduction, were obtained with aeration in the pressure tank with a spray system combined with diffused air bubbling. The Oerebro project in the beginning of the 1990s included on site testing of five different aeration solutions: Aeration in the drill hole, aeration in the storage tank, ejector aeration, shallow tray aeration and packed column aeration. The radon removal efficiency varied between 20 % and 99 %. In 1994 a study intended to test the radon removal capacity of different water treatment equipment was performed. Six units of radon separators were included but most of the tested equipment was installed for other water treatment purposes. The performed measurements showed that the only types of equipment that reduce the radon concentration efficiently are radon separators and reverse osmosis filters. The radon removal capacity of the radon separators varied between 23 % and 97 %. In 1996 the nine most common radon separators on the Swedish market were tested. The results showed that the tested radon removal equipment worked well, although the technical quality and chosen technical solutions were not always the best. The radon removal capacity of the units participating in this test was in most cases between 96 and 99 %. In some cases the capacity exceeded 99 %. In order to reach this radon removal capacity the water must be recirculated in a storage tank under atmospheric pressure.

  16. Performance and Reliability of Bonded Interfaces for High-Temperature Packaging. Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    DeVoto, Douglas [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-04-01

    Current generation automotive power electronics packages utilize silicon devices and lead-free solder alloys. To meet stringent technical targets for 2020 and beyond (for cost, power density, specific power, efficiency and reliability), wide-bandgap devices are being considered since they offer advantages such as operation at higher frequencies, voltages, and temperatures. Traditional power electronics packages must be redesigned to utilize the full potential of wide-bandgap devices, and the die- and substrate-attach layers are key areas where new material development and validation is required. Present solder alloys do not meet the performance requirements for these new package designs while also meeting cost and hazardous substance restrictions. Sintered silver (Ag) promises to meet the needs for die- and substrate-attach interfaces but synthesis optimization and reliability evaluation must be completed. Sintered Ag material was proposed as an alternative solution in power electronics packages almost 20 years back. However, synthesis pressure requirements up 40 MPa caused a higher complexity in the production process and more stringent flatness specifications for the substrates. Recently, several manufacturers have developed sintered Ag materials that require lower (3-5 MPa) or even no bonding pressures. Degradation mechanisms for these sintered Ag materials are not well known and need to be addressed. We are addressing these aspects to some extent in this project. We are developing generalized (i.e., independent of geometry) stress intensity factor versus cycles-to-failure relations for sintered Ag. Because sintered Ag is a relatively new material for automotive power electronics, the industry currently does not have a good understanding of recommended synthesis parameters or expected reliability under prescribed conditions. It is an important deliverable of this project to transfer findings to industry to eliminate barriers to using sintered Ag as a viable and

  17. The reliability and utility of spirometry performed on people with asthma in community pharmacies.

    Science.gov (United States)

    Lei Burton, Deborah; LeMay, Kate S; Saini, Bandana; Smith, Lorraine; Bosnic-Anticevich, Sinthia; Southwell, Phillipa; Cooke, Julie; Emmerton, Lynne; Stewart, Kay; Krass, Ines; Reddel, Helen; Armour, Carol

    2015-01-01

    To investigate the reliability and the utility of spirometry generated by community pharmacists participating in two large asthma intervention trials of 892 people. The Pharmacy Asthma Care Program (PACP) and the Pharmacy Asthma Management Service (PAMS) involved up to four visits to the pharmacy over 6 months for counseling and goal setting. Pharmacists performed spirometry according to ATS/ERS guidelines to inform management. The proportion of A-E, F quality tests, as per EasyOne QC grades, were recorded. Lung function results between visits and for participants referred/not referred to their general practitioner on the basis of spirometry were compared. Complete data from 2593 spirometry sessions were recorded, 68.5% of spirometry sessions achieved three acceptable tests with between-test repeatability of 150 ml or less (A or B quality), 96% of spirometry sessions included at least one test that met ATS/ERS acceptability criteria. About 39.1% of participants had FEV1/FVC values below the lower limit of normal (LNN), indicating a respiratory obstruction. As a result of the service, there was a significant increase in FEV1 and FEV1/FVC and asthma control. Lung function values were significantly poorer for participants referred to their general practitioner, compared with those not referred, on the basis of spirometry. Community pharmacists are able to reliably achieve spirometry results meeting ATS/ERS guidelines in people with asthma. Significant improvements in airway obstruction were demonstrated with the pharmacy services. Pharmacists interpreted lung function results to identify airway obstruction for referral, making this a useful technique for review of people with asthma in the community.

  18. Reliability, validity and description of timed performance of the Jebsen-Taylor Test in patients with muscular dystrophies.

    Science.gov (United States)

    Artilheiro, Mariana Cunha; Fávero, Francis Meire; Caromano, Fátima Aparecida; Oliveira, Acary de Souza Bulle; Carvas, Nelson; Voos, Mariana Callil; Sá, Cristina Dos Santos Cardoso de

    2017-12-08

    The Jebsen-Taylor Test evaluates upper limb function by measuring timed performance on everyday activities. The test is used to assess and monitor the progression of patients with Parkinson disease, cerebral palsy, stroke and brain injury. To analyze the reliability, internal consistency and validity of the Jebsen-Taylor Test in people with Muscular Dystrophy and to describe and classify upper limb timed performance of people with Muscular Dystrophy. Fifty patients with Muscular Dystrophy were assessed. Non-dominant and dominant upper limb performances on the Jebsen-Taylor Test were filmed. Two raters evaluated timed performance for inter-rater reliability analysis. Test-retest reliability was investigated by using intraclass correlation coefficients. Internal consistency was assessed using the Cronbach alpha. Construct validity was conducted by comparing the Jebsen-Taylor Test with the Performance of Upper Limb. The internal consistency of Jebsen-Taylor Test was good (Cronbach's α=0.98). A very high inter-rater reliability (0.903-0.999), except for writing with an Intraclass correlation coefficient of 0.772-1.000. Strong correlations between the Jebsen-Taylor Test and the Performance of Upper Limb Module were found (rho=-0.712). The Jebsen-Taylor Test is a reliable and valid measure of timed performance for people with Muscular Dystrophy. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  19. Quantitative developments in the cognitive reliability and error analysis method (CREAM) for the assessment of human performance

    International Nuclear Information System (INIS)

    Marseguerra, Marzio; Zio, Enrico; Librizzi, Massimo

    2006-01-01

    The current 'second generation' approaches in human reliability analysis focus their attention on the contextual conditions under which a given action is performed rather than on the notion of inherent human error probabilities, as was done in the earlier 'first generation' techniques. Among the 'second generation' methods, this paper considers the Cognitive Reliability and Error Analysis Method (CREAM) and proposes some developments with respect to a systematic procedure for computing probabilities of action failure. The starting point for the quantification is a previously introduced fuzzy version of the CREAM paradigm which is here further extended to include uncertainty on the qualification of the conditions under which the action is performed and to account for the fact that the effects of the common performance conditions (CPCs) on performance reliability may not all be equal. By the proposed approach, the probability of action failure is estimated by rating the performance conditions in terms of their effect on the action

  20. Principles of performance and reliability modeling and evaluation essays in honor of Kishor Trivedi on his 70th birthday

    CERN Document Server

    Puliafito, Antonio

    2016-01-01

    This book presents the latest key research into the performance and reliability aspects of dependable fault-tolerant systems and features commentary on the fields studied by Prof. Kishor S. Trivedi during his distinguished career. Analyzing system evaluation as a fundamental tenet in the design of modern systems, this book uses performance and dependability as common measures and covers novel ideas, methods, algorithms, techniques, and tools for the in-depth study of the performance and reliability aspects of dependable fault-tolerant systems. It identifies the current challenges that designers and practitioners must face in order to ensure the reliability, availability, and performance of systems, with special focus on their dynamic behaviors and dependencies, and provides system researchers, performance analysts, and practitioners with the tools to address these challenges in their work. With contributions from Prof. Trivedi's former PhD students and collaborators, many of whom are internationally recognize...

  1. Science-Based Simulation Model of Human Performance for Human Reliability Analysis

    International Nuclear Information System (INIS)

    Kelly, Dana L.; Boring, Ronald L.; Mosleh, Ali; Smidts, Carol

    2011-01-01

    Human reliability analysis (HRA), a component of an integrated probabilistic risk assessment (PRA), is the means by which the human contribution to risk is assessed, both qualitatively and quantitatively. However, among the literally dozens of HRA methods that have been developed, most cannot fully model and quantify the types of errors that occurred at Three Mile Island. Furthermore, all of the methods lack a solid empirical basis, relying heavily on expert judgment or empirical results derived in non-reactor domains. Finally, all of the methods are essentially static, and are thus unable to capture the dynamics of an accident in progress. The objective of this work is to begin exploring a dynamic simulation approach to HRA, one whose models have a basis in psychological theories of human performance, and whose quantitative estimates have an empirical basis. This paper highlights a plan to formalize collaboration among the Idaho National Laboratory (INL), the University of Maryland, and The Ohio State University (OSU) to continue development of a simulation model initially formulated at the University of Maryland. Initial work will focus on enhancing the underlying human performance models with the most recent psychological research, and on planning follow-on studies to establish an empirical basis for the model, based on simulator experiments to be carried out at the INL and at the OSU.

  2. Element nodes of sports equipment double back flip factions and double back flip hunched performed gymnast in floor exercise

    Directory of Open Access Journals (Sweden)

    V.A. Potop

    2014-07-01

    Full Text Available Purpose: to identify the node elements of sports equipment double back somersault tuck and double back flip bent. To compare the two types of nodes for double somersault. Material : the study involved eight gymnasts (age 12 - 14 years. All finalists in the competition floor exercise - reserve team Romania. The method of video - computer research and method of postural orientation movements. Results : identified nodal elements of sports equipment double back somersault tuck and double back flip bent. In the preparatory phase of motor actions - launcher body posture for reaching is repulsive to flip. In the phase of basic motor action - animation body postures (double back somersault tuck and bent (bent double back flip. Exercises are performed on the ascending and descending parts of the flight path of the demonstration of individual maximum lift height common center of mass. In the final phase of motor actions - final body posture - steady landing. Conclusions : indicators of key elements of sports equipment acrobatic exercises contain new scientific facts kinematic and dynamic structures of motor actions. They are necessary for the development of modern training programs acrobatic exercises in step specialized base preparation.

  3. Improvements in Thermal Performance of Mango Hot-water Treatment Equipments: Data Analysis, Mathematical Modelling and Numerical-computational Simulation

    Directory of Open Access Journals (Sweden)

    Elder M. Mendoza Orbegoso

    2017-06-01

    Full Text Available Mango is one of the most popular and best paid tropical fruits in worldwide markets, its exportation is regulated within a phytosanitary quality control for killing the “fruit fly”. Thus, mangoes must be subject to hot-water treatment process that involves their immersion in hot water over a period of time. In this work, field measurements, analytical and simulation studies are developed on available hot-water treatment equipment called “Original” that only complies with United States phytosanitary protocols. These approaches are made to characterize the fluid-dynamic and thermal behaviours that occur during the mangoes’ hot-water treatment process. Then, analytical model and Computational fluid dynamics simulations are developed for designing new hot-water treatment equipment called “Hybrid” that simultaneously meets with both United States and Japan phytosanitary certifications. Comparisons of analytical results with data field measurements demonstrate that “Hybrid” equipment offers a better fluid-dynamic and thermal performance than “Original” ones.

  4. Performance of a resistive plate chamber equipped with a new prototype of amplified front-end electronics

    CERN Document Server

    Marchisone, Massimiliano

    2016-01-01

    ALICE is the LHC experiment dedicated to the study of heavy-ion collisions. At forward rapidity a muon spectrometer detects muons from low mass mesons, quarkonia, open heavy-flavor hadrons as well as weak bosons. A muon selection based on transverse momentum is made by a trigger system composed of 72 resistive plate chambers (RPCs). For the LHC Run 1 and the ongoing Run 2 the RPCs have been equipped with a non-amplified FEE called ADULT. However, in view of an increase in luminosity expected for Run 3 (2021-2023) the possibility to use an amplified FEE has been explored in order to improve the counting rate limitation and to prevent the aging of the detector, by reducing the charge per hit. A prototype of this new electronics (FEERIC) has been developed and tested first with cosmic rays before equipping one RPC in the ALICE cavern with it. In this talk the most important performance indicators - efficiency, dark current, dark rate, cluster size and total charge - of an RPC equipped with this new FEE will be r...

  5. Abreu system - dosimetric system to evaluate the performance of the basic parameters of photofluorographic equipments

    International Nuclear Information System (INIS)

    Silva Feita, J.C. da.

    1986-01-01

    In Brazil, photofluorographic X-ray machines are used for tuberculosis mass screening throughout the country. The exact number of these X-ray equipment is unknown, but it is estimated to be around 1000 operating units. Twelve million miniature chest radiographs are taken per year. In order to make local inspections speedier and also aiming at its postal use, a system has been developed which evaluates the entrance exposure of the patients, the X-ray beam half-value layer (leading to the evaluation of the tube's total filtration) and the beam's field size. It consists of a piece of cardboard where filters, TLDs and X-ray films are inserted. So far the system has been tested in 53 X-ray machines. The results show that it can be used in a national survey program. The data collected were used for the calculation of doses and this showed the influence of field size and tube voltage on the dose to the thyroid, uterus, ovaries, bone marrow and lungs. Furthermore, the results can be used to estimate population doses and risks factors due to photofluorographic examinations. (author)

  6. Field performance evaluation during fog-dominated wintertime of a newly developed denuder-equipped PM1 sampler.

    Science.gov (United States)

    Singh, Dharmendra Kumar; Lakshay; Gupta, Tarun

    2014-03-01

    This study presents the performance evaluation of a novel denuder-equipped PM1 (particles having aerodynamic diameter less than 1 μm) sampler, tested during fog-dominated wintertime, in the city of Kanpur, India. One PM1 sampler and one denuder-equipped PM1 sampler were co-located to collect ambient PM1 for 25 days. The mean PM1 mass concentration measured on foggy days with the PM1 sampler and the denuder-equipped PM1 sampler was found to be 165.95 and 135.48 μg/m(3), respectively. The mean PM1 mass concentration measured on clear days with the PM1 sampler and the denuder-equipped PM1 sampler was observed to be 159.66 and 125.14 μg/m(3), respectively. The mass concentration with denuder-fitted PM1 sampler for both foggy and clear days was always found less than the PM1 sampler. The same drift was observed in the concentrations of water-soluble ions and water-soluble organic carbon (WSOC). Moreover, it was observed that the use of denuder leads to a significant reduction in the PM positive artifact. The difference in the concentration of chemical species obtained by two samplers indicates that the PM1 sampler without denuder had overestimated the concentrations of chemical species in a worst-case scenario by almost 40 %. Denuder-fitted PM1 sampler can serve as a useful sampling tool in estimating the true values for nitrate, ammonium, potassium, sodium and WSOC present in the ambient PM.

  7. Validity and Reliability of Surface Electromyography Measurements from a Wearable Athlete Performance System

    Directory of Open Access Journals (Sweden)

    Scott K. Lynn, Casey M. Watkins, Megan A. Wong, Katherine Balfany, Daniel F. Feeney

    2018-06-01

    Full Text Available The Athos ® wearable system integrates surface electromyography (sEMG electrodes into the construction of compression athletic apparel. The Athos system reduces the complexity and increases the portability of collecting EMG data and provides processed data to the end user. The objective of the study was to determine the reliability and validity of Athos as compared with a research grade sEMG system. Twelve healthy subjects performed 7 trials on separate days (1 baseline trial and 6 repeated trials. In each trial subjects wore the wearable sEMG system and had a research grade sEMG system’s electrodes placed just distal on the same muscle, as close as possible to the wearable system’s electrodes. The muscles tested were the vastus lateralis (VL, vastus medialis (VM, and biceps femoris (BF. All testing was done on an isokinetic dynamometer. Baseline testing involved performing isometric 1 repetition maximum tests for the knee extensors and flexors and three repetitions of concentric-concentric knee flexion and extension at MVC for each testing speed: 60, 180, and 300 deg/sec. Repeated trials 2-7 each comprised 9 sets where each set included three repetitions of concentric-concentric knee flexion-extension. Each repeated trial (2-7 comprised one set at each speed and percent MVC (50%, 75%, 100% combination. The wearable system and research grade sEMG data were processed using the same methods and aligned in time. The amplitude metrics calculated from the sEMG for each repetition were the peak amplitude, sum of the linear envelope, and 95th percentile. Validity results comprise two main findings. First, there is not a significant effect of system (Athos or research grade system on the repetition amplitude metrics (95%, peak, or sum. Second, the relationship between torque and sEMG is not significantly different between Athos and the research grade system. For reliability testing, the variation across trials and averaged across speeds was 0.8%, 7

  8. The performance of a prototype device designed to evaluate general quality parameters of X-ray equipment

    International Nuclear Information System (INIS)

    Murata, C.H.; Fernandes, D.C.; Lavínia, N.C.; Caldas, L.V.E; Pires, S.R; Medeiros, R.B.

    2014-01-01

    The performance of radiological equipment can be assessed using non-invasive methods and portable instruments that can analyze an X-ray beam with just one exposure. These instruments use either an ionization chamber or a state solid detector (SSD) to evaluate X-ray beam parameters. In Brazil, no such instruments are currently being manufactured; consequently, these instruments come at a higher cost to users due to importation taxes. Additionally, quality control tests are time consuming and impose a high workload on the X-ray tubes when evaluating their performance parameters. The assessment of some parameters, such as the half-value layer (HVL), requires several exposures; however, this can be reduced by using a SSD that requires only a single exposure. One such SSD uses photodiodes designed for high X-ray sensitivity without the use of scintillation crystals. This sensitivity allows one electron-hole pair to be created per 3.63 eV of incident energy, resulting in extremely high and stable quantum efficiencies. These silicon photodiodes operate by absorbing photons and generating a flow of current that is proportional to the incident power. The aim of this study was to show the response of the solid sensor PIN RD100A detector in a multifunctional X-ray analysis system that is designed to evaluate the average peak voltage (kVp), exposure time, and HVL of radiological equipment. For this purpose, a prototype board that uses four SSDs was developed to measure kVp, exposure time, and HVL using a single exposure. The reproducibility and accuracy of the results were compared to that of different X-ray beam analysis instruments. The kVp reproducibility and accuracy results were 2% and 3%, respectively; the exposure time reproducibility and accuracy results were 2% and 1%, respectively; and the HVL accuracy was ±2%. The prototype's methodology was able to calculate these parameters with appropriate reproducibility and accuracy. Therefore, the prototype can be considered

  9. Measuring Ucrit and endurance: equipment choice influences estimates of fish swimming performance.

    Science.gov (United States)

    Kern, P; Cramp, R L; Gordos, M A; Watson, J R; Franklin, C E

    2018-01-01

    This study compared the critical swimming speed (U crit ) and endurance performance of three Australian freshwater fish species in different swim-test apparatus. Estimates of U crit measured in a large recirculating flume were greater for all species compared with estimates from a smaller model of the same recirculating flume. Large differences were also observed for estimates of endurance swimming performance between these recirculating flumes and a free-surface swim tunnel. Differences in estimates of performance may be attributable to variation in flow conditions within different types of swim chambers. Variation in estimates of swimming performance between different types of flumes complicates the application of laboratory-based measures to the design of fish passage infrastructure. © 2017 The Fisheries Society of the British Isles.

  10. Double-shell tank integrity assessments ultrasonic test equipment performance test

    Energy Technology Data Exchange (ETDEWEB)

    Pfluger, D.C.

    1996-09-26

    A double-shell tank (DST) inspection (DSTI) system was performance tested over three months until August 1995 at Pittsburgh, Pennsylvania, completing a contract initiated in February 1993 to design, fabricate, and test an ultrasonic inspection system intended to provide ultrasonic test (UT) and visual data to determine the integrity of 28 DSTs at Hanford. The DSTs are approximately one-million-gallon underground radioactive-waste storage tanks. The test was performed in accordance with a procedure (Jensen 1995) that included requirements described in the contract specification (Pfluger 1995). This report documents the results of tests conducted to evaluate the performance of the DSTI system against the requirements of the contract specification. The test of the DSTI system also reflects the performance of qualified personnel and operating procedures.

  11. Novel Scanning Lens Instrument for Evaluating Fresnel Lens Performance: Equipment Development and Initial Results (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Herrero, R.; Miller, D. C.; Kurtz, S. R.; Anton, I.; Sala, G.

    2013-07-01

    A system dedicated to the optical transmittance characterization of Fresnel lenses has been developed at NREL, in collaboration with the UPM. The system quantifies the optical efficiency of the lens by generating a performance map. The shape of the focused spot may also be analyzed to understand change in the lens performance. The primary instrument components (lasers and CCD detector) have been characterized to confirm their capability for performing optical transmittance measurements. Measurements performed on SoG and PMMA lenses subject to a variety of indoor conditions (e.g., UV and damp heat) identified differences in the optical efficiency of the evaluated lenses, demonstrating the ability of the Scanning Lens Instrument (SLI) to distinguish between the aged lenses.

  12. Postal auditing methodology used to find out the performance of high rate brachytherapy equipment

    International Nuclear Information System (INIS)

    Morales, J.A.; Campa, R.

    1998-01-01

    This work describes results from a methodology implemented at the Secondary Laboratory for Dosimetric Calibration at CPHR used to check the brachytherapy performance at high doses rate using Cesium 137 or cobalt 60 sources

  13. Performance measurement using overall equipment effectiveness (OEE): Literature review and practical application discussion

    OpenAIRE

    Pintelon , Liliane M-Y A; Muchiri , Peter Nganga

    2008-01-01

    Abstract The quest for improving productivity in the current global competitive environment has led to a need for a rigorously defined performance measurement systems for manufacturing processes. In this paper, OEE is described as such kind of performance measurement tool that measures different types of production losses and indicates areas of process improvement. Analysis is done on how OEE has evolved leading to other tools like TEEP, PEE, OFE, OPE and OAE. Two industrial exampl...

  14. Development, construct validity and test–retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball

    NARCIS (Netherlands)

    de Witte, AMH; Hoozemans, MJM; Berger, MAM; van der Slikke, R.M.A.; van der Woude, LHV; Veeger, H.E.J.

    2018-01-01

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation

  15. Development, construct validity and test-retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball

    NARCIS (Netherlands)

    de Witte, Annemarie M. H.; Hoozemans, Marco J. M.; Berger, Monique A. M.; van der Slikke, Rienk M. A.; van der Woude, Lucas H. V.; Veeger, Dirkjan (H. E. J)

    2018-01-01

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation of

  16. Development, construct validity and test–retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball

    NARCIS (Netherlands)

    de Witte, Annemarie M H; Hoozemans, Marco J M; Berger, Monique A M; van der Slikke, Rienk M A; van der Woude, Lucas H V; Veeger, Dirkjan (H E J)

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation of

  17. Human reliability analysis of performing tasks in plants based on fuzzy integral

    International Nuclear Information System (INIS)

    Washio, Takashi; Kitamura, Yutaka; Takahashi, Hideaki

    1991-01-01

    The effective improvement of the human working conditions in nuclear power plants might be a solution for the enhancement of the operation safety. The human reliability analysis (HRA) gives a methodological basis of the improvement based on the evaluation of human reliability under various working conditions. This study investigates some difficulties of the human reliability analysis using conventional linear models and recent fuzzy integral models, and provides some solutions to the difficulties. The following practical features of the provided methods are confirmed in comparison with the conventional methods: (1) Applicability to various types of tasks (2) Capability of evaluating complicated dependencies among working condition factors (3) A priori human reliability evaluation based on a systematic task analysis of human action processes (4) A conversion scheme to probability from indices representing human reliability. (author)

  18. A Bayesian reliability approach to the performance assessment of a geological waste repository

    International Nuclear Information System (INIS)

    Flueck, J.A.; Singh, A.K.

    1992-01-01

    This paper discusses the task of selecting a suitable site for a high-level waste disposal repository (HLWR) which certainly is a complex one in that one must address both engineering and economic factors of the proposed facility and site as well as environmental, public health, safety, and sociopolitical factors. Acknowledging the complexity of the siting problem for a HLWR leads one to readily conclude that a formal analysis, including the use of a performance assessment model (PAM), is needed to assist the designated decision makers in their task of selecting a suitable site. The overall goal of a PAM is to aid the decision makers in making the best possible technical siting decision. For a number of reason, the authors believe that the combining of both Bayesian decision theory and reliability methodology provides the best approach to constructing a useful PAM for assisting in the siting of a HLWR. This combination allows one to formally integrate existing relevant information, professional judgement, and component model outputs to produce conditionally estimated probabilities for a decision tree approach to the radionuclide release problem of a proposed HLWR. If loss functions are available, this also allows one to calculate the expected costs or losses from possible radionuclide releases. This latter calculation may be very important in selecting the final site from among a number of alternative sites

  19. The Effect of Patient Characteristics and Sleep Quality on Visual Field Performance Reliability

    Directory of Open Access Journals (Sweden)

    Swarup S. Swaminathan

    2018-01-01

    Full Text Available Purpose. To investigate the association of automated visual field (VF reliability indices (false positive [FP], false negative [FN], and fixation loss [FL] and sleep quality, VF experience, and age. Methods. Prospective, cross-sectional study. Adult patients (age ≥ 18 years completing automated VF testing were invited to participate. Baseline participant characteristics were obtained, and all participants were asked to complete the Pittsburgh Sleep Quality Index (PSQI questionnaire. Nonparametric Spearman correlations and logistical regression models were performed. Results. 63 patients were enrolled. Lower PSQI score was correlated with higher percentage (% FL in the right eye (p=0.03. Fewer prior VF was significantly correlated with higher %FP in the right eye (p=0.008. Older age was significantly correlated with higher %FN in the left eye (p=0.01. Greater mean deviation (MD and pattern standard deviation (PSD were strongly correlated with higher %FN in the right (p=0.02 and 0.002, resp. and left eyes (p=0.01 and 0.02, resp.. Conclusion. In this prospective, cross-sectional study, worse MD and PSD are strongly correlated with increased FN in both eyes. Increased FN in the left eye associated with older age might be attributable to test fatigue. Worse sleep quality is associated with decreased FL in the right eye.

  20. Performance and Reliability of DSRC Vehicular Safety Communication: A Formal Analysis

    Directory of Open Access Journals (Sweden)

    2009-02-01

    Full Text Available IEEE- and ASTM-adopted dedicated short range communications (DSRC standard toward 802.11p is a key enabling technology for the next generation of vehicular safety communication. Broadcasting of safety messages is one of the fundamental services in DSRC. There have been numerous publications addressing design and analysis of such broadcast ad hoc system based on the simulations. For the first time, an analytical model is proposed in this paper to evaluate performance and reliability of IEEE 802.11a-based vehicle-to-vehicle (V2V safety-related broadcast services in DSRC system on highway. The proposed model takes two safety services with different priorities, nonsaturated message arrival, hidden terminal problem, fading transmission channel, transmission range, IEEE 802.11 backoff counter process, and highly mobile vehicles on highway into account. Based on the solutions to the proposed analytic model, closed-form expressions of channel throughput, transmission delay, and packet reception rates are derived. From the obtained numerical results under various offered traffic and network parameters, new insights and enhancement suggestions are given.

  1. Meteorological measurements performed at the Saclay Centre of Nuclear Studies, and used equipment

    International Nuclear Information System (INIS)

    Levrard, A.

    1960-01-01

    This note first recalls the objective of meteorological measurements performed at the CENS station atmospheric radioactivity control station. It briefly recalls some definitions and notions in meteorology: atmosphere vertical structure, atmospheric humidity, atmospheric pressure, weather fronts and passage of disturbances, cloud systems. It indicates measurements performed on a daily basis (temperature in the shelter, minimum and maximum temperature, relative humidity, dew point temperature, atmospheric pressure, soil condition, present weather, visibility, past weather, cloudiness, precipitations, miscellaneous phenomena), recorded measurements (wind strength and direction, atmospheric pressure, relative humidity, temperature, pluviometry), while indicating and presenting corresponding measurement devices

  2. The reliability of team-based primary data collectors for the collection of exposure and protective equipment use data in community sport

    OpenAIRE

    Braham, R; Finch, C

    2004-01-01

    Methods: Nine clubs (23 teams) from a metropolitan Australian Football league in Victoria each provided one primary data collector to monitor exposure and protective equipment use over a regular playing season. Four random audits of this data collection for each team were conducted throughout the regular playing season. The audits were compared with data collected by the club data collectors and the level of agreement assessed.

  3. Reliability and Validity of the Turkish Language Version of the Test of Performance Strategies

    Directory of Open Access Journals (Sweden)

    Miçooğulları Bülent Okan

    2017-03-01

    Full Text Available The aim of the present study was to examine the psychometric properties of the Test of Performance Strategies (TOPS; Thomas et al., 1999 on the Turkish population. The TOPS was designed to assess eight psychological skills and strategies used by athletes in competition (activation, automaticity, emotional control, goal-setting, imagery, relaxation, self-talk, and negative thinking and the same strategies, except negative thinking is replaced by attentional control used in training. The sample of the study included athletes who were training and competing in a wide variety of sports across a broad range of performance standards. The final sample consisted of 433 males (mean ± s: age 22.47 ± 5.30 years and 187 females (mean ± s: age 20.97 ± 4.78 years, 620 athletes in total (mean ± s: age 21.25 ± 4.87 years who voluntarily participated; TOPS was administered to all participants. Afterward, Confirmatory Factor Analysis (CFA was conducted by Analysis Moments of Structures (AMOS 18. Comparative fit index (CFI, non-normed fit index (NNFI and root mean square error of approximation (RMSEA were used to verify whether the model fit the data. Goodness-of-fit statistics were CFI= .91, NNFI= .92 and RMSEA= .056. These values showed that the tested model is coherent at a satisfactory level. Moreover, results of confirmatory factor analyses revealed that a total of four items (two items from competition and two from practice within the subscale of automaticity have been removed. The 28 items within the remaining seven subscales have been validated. In conclusion, Turkish version of TOPS is a valid and reliable instrument to assess the psychological skills and strategies used by athletes in competition and practices.

  4. Application of objective clinical human reliability analysis (OCHRA) in assessment of technical performance in laparoscopic rectal cancer surgery.

    Science.gov (United States)

    Foster, J D; Miskovic, D; Allison, A S; Conti, J A; Ockrim, J; Cooper, E J; Hanna, G B; Francis, N K

    2016-06-01

    Laparoscopic rectal resection is technically challenging, with outcomes dependent upon technical performance. No robust objective assessment tool exists for laparoscopic rectal resection surgery. This study aimed to investigate the application of the objective clinical human reliability analysis (OCHRA) technique for assessing technical performance of laparoscopic rectal surgery and explore the validity and reliability of this technique. Laparoscopic rectal cancer resection operations were described in the format of a hierarchical task analysis. Potential technical errors were defined. The OCHRA technique was used to identify technical errors enacted in videos of twenty consecutive laparoscopic rectal cancer resection operations from a single site. The procedural task, spatial location, and circumstances of all identified errors were logged. Clinical validity was assessed through correlation with clinical outcomes; reliability was assessed by test-retest. A total of 335 execution errors identified, with a median 15 per operation. More errors were observed during pelvic tasks compared with abdominal tasks (p technical performance of laparoscopic rectal surgery.

  5. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD.

    Science.gov (United States)

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A; Campos, Michael A; Cahalin, Lawrence P

    2018-01-01

    The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Test-retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test-retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. The TIRE measures of MIP, SMIP and ID have excellent test-retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP.

  6. Performance of on-power fuelling equipment at Rajasthan Atomic Power Station

    International Nuclear Information System (INIS)

    Jayabarathan, S.; Gopalakrishnan, S.

    1977-01-01

    Natural uranium reactors on account of their intrinsically low reactivity need frequent refuelling. The Rajasthan Atomic Power Station based on natural uranium reactors has, therefore, been provided with on-power fuel handling system which was installed in 1972. Its performance has met the design intent and operational objectives which are enumerated. However, continuous fuelling 7 to 10 days has not been possible because frequent maintenance of refuelling system is needed on account of certain deficiencies major of which is the heavy water leakage. For better performance, installation of a programmable logic controller is suggested. Mention has also been made of inadequate number of skilled man-power required for maintenance which leads to quick depletion of man-rem of all the available personnel trained for maintenance work. (M.G.B.)

  7. Equipment and performance of the Q3D spectrometer installed at the tandem laboratory of Saclay

    International Nuclear Information System (INIS)

    Berthier, B.

    1979-01-01

    A quadrupole - dipole - dipole - dipole (Q3D) magnetic spectrometer with proportional gas counter which has been installed at the tandem laboratory of Saclay is described. Typical results are given indicating the performance of the apparatus in studies of heavy ion reactions at tandem energies for which good energy resolution and large solid angles are required. Improvements to allow the detection of heavier masses and less energetic ions with better energy resolution are planned. (U.K.)

  8. A study on the establishment of component/equipment performance criteria considering Heavy Water Reactor characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Keun Sun; Kwon, Young Chul; Lee, Min Kyu; Lee, Yun Soo [Sunmoon Univ., Asan (Korea, Republic of); Chang, Seong Hoong; Ryo, Chang Hyun [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of); Kim, Soong Pyung; Hwnag, Jung Rye; Chung, Chul Kee [Chosun Univ., Gwangju (Korea, Republic of)

    2002-03-15

    Foreign and domestic technology trends, regulatory requirements, design and researches for heavy water reactors are analyzed. Safety design guides of Canada industry and regulatory documents and consultative documents of Canada regulatory agency are reviewed. Applicability of MOST guidance 16 Revision 'guidance for technical criteria of nuclear reactor facility' is reviewed. Specific performance criteria are established for components and facilities for heavy water reactor.

  9. Performance simulation of the JPL solar-powered distiller. Part 1: Quasi-steady-state conditions. [for cooling microwave equipment

    Science.gov (United States)

    Yung, C. S.; Lansing, F. L.

    1983-01-01

    A 37.85 cu m (10,000 gallons) per year (nominal) passive solar powered water distillation system was installed and is operational in the Venus Deep Space Station. The system replaced an old, electrically powered water distiller. The distilled water produced with its high electrical resistivity is used to cool the sensitive microwave equipment. A detailed thermal model was developed to simulate the performance of the distiller and study its sensitivity under varying environment and load conditions. The quasi-steady state portion of the model is presented together with the formulas for heat and mass transfer coefficients used. Initial results indicated that a daily water evaporation efficiency of 30% can be achieved. A comparison made between a full day performance simulation and the actual field measurements gave good agreement between theory and experiment, which verified the model.

  10. The intra- and inter-rater reliability of five clinical muscle performance tests in patients with and without neck pain

    Science.gov (United States)

    2013-01-01

    Background This study investigates the reliability of muscle performance tests using cost- and time-effective methods similar to those used in clinical practice. When conducting reliability studies, great effort goes into standardising test procedures to facilitate a stable outcome. Therefore, several test trials are often performed. However, when muscle performance tests are applied in the clinical setting, clinicians often only conduct a muscle performance test once as repeated testing may produce fatigue and pain, thus variation in test results. We aimed to investigate whether cervical muscle performance tests, which have shown promising psychometric properties, would remain reliable when examined under conditions similar to those of daily clinical practice. Methods The intra-rater (between-day) and inter-rater (within-day) reliability was assessed for five cervical muscle performance tests in patients with (n = 33) and without neck pain (n = 30). The five tests were joint position error, the cranio-cervical flexion test, the neck flexor muscle endurance test performed in supine and in a 45°-upright position and a new neck extensor test. Results Intra-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.48-0.82), the cranio-cervical flexion test (ICC ≥ 0.69), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.68) and in a 45°-upright position (ICC ≥ 0.41) with the exception of a new test (neck extensor test), which ranged from slight to moderate agreement (ICC = 0.14-0.41). Likewise, inter-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.51-0.75), the cranio-cervical flexion test (ICC ≥ 0.85), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.70) and in a 45°-upright position (ICC ≥ 0.56). However, only slight to fair agreement was found for the neck extensor test (ICC

  11. Adequate performance of cardiopulmonary resuscitation techniques during simulated cardiac arrest over and under protective equipment in football.

    Science.gov (United States)

    Waninger, Kevin N; Goodbred, Andrew; Vanic, Keith; Hauth, John; Onia, Joshua; Stoltzfus, Jill; Melanson, Scott

    2014-07-01

    To investigate (1) cardiopulmonary resuscitation (CPR) adequacy during simulated cardiac arrest of equipped football players and (2) whether protective football equipment impedes CPR performance measures. Exploratory crossover study performed on Laerdal SimMan 3 G interactive manikin simulator. Temple University/St Luke's University Health Network Regional Medical School Simulation Laboratory. Thirty BCLS-certified ATCs and 6 ACLS-certified emergency department technicians. Subjects were given standardized rescuer scenarios to perform three 2-minute sequences of compression-only CPR. Baseline CPR sequences were captured on each subject. Experimental conditions included 2-minute sequences of CPR either over protective football shoulder pads or under unlaced pads. Subjects were instructed to adhere to 2010 American Heart Association guidelines (initiation of compressions alone at 100/min to 51 mm). Dependent variables included average compression depth, average compression rate, percentage of time chest wall recoiled, and percentage of hands-on contact during compressions. Differences between subject groups were not found to be statistically significant, so groups were combined (n = 36) for analysis of CPR compression adequacy. Compression depth was deeper under shoulder pads than over (P = 0.02), with mean depths of 36.50 and 31.50 mm, respectively. No significant difference was found with compression rate or chest wall recoil. Chest compression depth is significantly decreased when performed over shoulder pads, while there is no apparent effect on rate or chest wall recoil. Although the clinical outcomes from our observed 15% difference in compression depth are uncertain, chest compression under the pads significantly increases the depth of compressions and more closely approaches American Heart Association guidelines for chest compression depth in cardiac arrest.

  12. Correlation Relationship of Performance Shaping Factors (PSFs) for Human Reliability Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bheka, M. Khumalo; Kim, Jonghyun [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2014-10-15

    At TMI-2, operators permitted thousands of gallons of water to escape from the reactor plant before realizing that the coolant pumps were behaving abnormally. The coolant pumps were then turned off, which in turn led to the destruction of the reactor itself as cooling was completely lost within the core. Human also plays a role in many aspects of complex systems e.g. in design and manufacture of hardware, interface between human and system and also in maintaining such systems as well as for coping with unusual events that place the NPP system at a risk. This is why human reliability analysis (HRA) - an aspect of risk assessments which systematically identifies and analyzes the causes and consequences of human decisions and actions - is important in nuclear power plant operations. It either upgrades or degrades human performance; therefore it has an impact on the possibility of error. These PSFs can be used in various HRA methods to estimate Human Error Probabilities (HEPs). There are many current HRA methods who propose sets of PSFs for normal operation mode of NPP. Some of these PSFs in the sets have some degree of dependency and overlap. Overlapping PSFs introduce error in HEP evaluations due to the fact that some elements are counted more than once in data; this skews the relationship amongst PSF and masks the way that the elements interact to affect performance. This study uses a causal model that represents dependencies and relationships amongst PSFs for HEP evaluation during normal NPP operational states. The model is built taking into consideration the dependencies among PSFs and thus eliminating overlap. The use of an interdependent model of PSFs is expected to produce more accurate HEPs compared to other current methods. PSF sets produced in this study can be further used as nodes (variables) and directed arcs (causal influence between nodes) in HEP evaluation methods such as Bayesian belief (BN) networks. This study was done to estimate the relationships

  13. Reliability centered maintenance : a case study of railway transit maintenance to achieve optimal performance.

    Science.gov (United States)

    2010-12-01

    The purpose of this qualitative case study was to identify the types of obstacles and patterns experienced by a single heavy rail transit agency located in North America that embedded a Reliability Centered Maintenance (RCM) Process. The outcome of t...

  14. (House Municipal School wind energy system: equipment performance). Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    1985-05-14

    The performance of a Skyhawk horizontal axis wind system with a 3-blade, 15-ft upwind rotor is evaluated. The wind system was placed at the House Municipal School. The school is located between Tucumcari and Clovis, New Mexico and has an annual wind regime of 12 mi/h at a height of 33 ft. It was operated for 26 months and during that time has been out of service, due to breakdowns, 13 months. When the Skyhawk was operational, it generated between 100 and 700 kilowatt-hrs per month.

  15. Reliability of one-repetition maximum performance in people with chronic heart failure.

    Science.gov (United States)

    Ellis, Rachel; Holland, Anne E; Dodd, Karen; Shields, Nora

    2018-02-24

    Evaluate intra-rater and inter-rater reliability of the one-repetition maximum strength test in people with chronic heart failure. Intra-rater and inter-rater reliability study. A public tertiary hospital in northern metropolitan Melbourne. Twenty-four participants (nine female, mean age 71.8 ± 13.1 years) with mild to moderate heart failure of any aetiology. Lower limb strength was assessed by determining the maximum weight that could be lifted using a leg press. Intra-rater reliability was tested by one assessor on two separate occasions . Inter-rater reliability was tested by two assessors in random order. Intra-class correlation coefficients and 95% confidence intervals were calculated. Bland and Altman analyses were also conducted, including calculation of mean differences between measures ([Formula: see text]) and limits of agreement . Ten intra-rater and 21 inter-rater assessments were completed. Excellent intra-rater (intra-class correlation coefficient 2,1 0.96) and inter-rater (intra-class correlation coefficient 2,1 0.93) reliability was found. Intra-rater assessment showed less variability (mean difference 4.5 kg, limits of agreement -8.11 to 17.11 kg) than inter-rater agreement (mean difference -3.81 kg, limits of agreement -23.39 to 15.77 kg). One-repetition maximum determined using a leg press is a reliable measure in people with heart failure. Given its smaller limits of agreement, intra-rater testing is recommended. Implications for Rehabilitation Using a leg press to determine a one-repetition maximum we were able to demonstrate excellent inter-rater and intra-rater reliability using an intra-class correlation coefficient. The Bland and Altman levels of agreement were wide for inter-rater reliability and so we recommend using one assessor if measuring change in strength within an individual over time.

  16. Study of the test method for prediction of air conditioning equipment seasonal performance

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, S.B.

    1980-05-01

    The test procedure, Method of Testing, Rating and Estimating the Seasonal Performance of Central Air-Conditioners and Heat Pumps Operating in the Cooling Mode, has been analyzed. The analysis of the test procedure incorporated two main functions: (1) to determine the validity of the test procedure; and (2) to determine if there are other alternate methods of obtaining the same results with less testing burden. Data were collected from industry and analyzed for any significant trends. Certain conclusions are drawn about the energy efficiency ratios, degradation coefficients and seasonal energy efficiency ratios. An error analysis was performed on the test procedure to determine the approximate amount of error when using this procedure. A semi-empirical model assuming a first order system response was developed to determine the factors that affect the part-load and cooling-load factors. The corresponding transient characteristics are then determined in terms of a single time constant. A thermostat demand cycle is used to determine the relationship between on-time and cycle-time. Recommendations are made regarding an alternate method being used to determine the seasonal energy efficiency ratio.

  17. Evaluating the reliability of multi-body mechanisms: A method considering the uncertainties of dynamic performance

    International Nuclear Information System (INIS)

    Wu, Jianing; Yan, Shaoze; Zuo, Ming J.

    2016-01-01

    Mechanism reliability is defined as the ability of a certain mechanism to maintain output accuracy under specified conditions. Mechanism reliability is generally assessed by the classical direct probability method (DPM) derived from the first order second moment (FOSM) method. The DPM relies strongly on the analytical form of the dynamic solution so it is not applicable to multi-body mechanisms that have only numerical solutions. In this paper, an indirect probability model (IPM) is proposed for mechanism reliability evaluation of multi-body mechanisms. IPM combines the dynamic equation, degradation function and Kaplan–Meier estimator to evaluate mechanism reliability comprehensively. Furthermore, to reduce the amount of computation in practical applications, the IPM is simplified into the indirect probability step model (IPSM). A case study of a crank–slider mechanism with clearance is investigated. Results show that relative errors between the theoretical and experimental results of mechanism reliability are less than 5%, demonstrating the effectiveness of the proposed method. - Highlights: • An indirect probability model (IPM) is proposed for mechanism reliability evaluation. • The dynamic equation, degradation function and Kaplan–Meier estimator are used. • Then the simplified form of indirect probability model is proposed. • The experimental results agree well with the predicted results.

  18. On the Need for Reliable Seismic Input Assessment for Optimized Design and Retrofit of Seismically Isolated Civil and Industrial Structures, Equipment, and Cultural Heritage

    Science.gov (United States)

    Martelli, Alessandro

    2011-01-01

    Based on the experience of recent violent earthquakes, the limits of the methods that are currently used for the definition of seismic hazard are becoming more and more evident to several seismic engineers. Considerable improvement is felt necessary not only for the seismic classification of the territory (for which the probabilistic seismic hazard assessment—PSHA—is generally adopted at present), but also for the evaluation of local amplification. With regard to the first item, among others, a better knowledge of fault extension and near-fault effects is judged essential. The aforesaid improvements are particularly important for the design of seismically isolated structures, which relies on displacement. Thus, such a design requires an accurate definition of the maximum value of displacement corresponding to the isolation period, and a reliable evaluation of the earthquake energy content at the low frequencies that are typical of the isolated structures, for the site and ground of interest. These evaluations shall include possible near-fault effects even in the vertical direction; for the construction of high-risk plants and components and retrofit of some cultural heritage, they shall be performed for earthquakes characterized by very long return periods. The design displacement shall not be underestimated, but neither be excessively overestimated, at least when using rubber bearings in the seismic isolation (SI) system. In fact, by decreasing transverse deformation of such SI systems below a certain value, their horizontal stiffness increases. Thus, should a structure (e.g. a civil defence centre, a masterpiece, etc.) protected in the aforesaid way be designed to withstand an unnecessarily too large earthquake, the behaviour of its SI system will be inadequate (i.e. it will be too stiff) during much more frequent events, which may really strike the structure during its life. Furthermore, since SI can be used only when the room available to the structure

  19. The Effect of Epoxy Molding Compound Floor Life to Reliability Performance and mold ability for QFN Package

    Science.gov (United States)

    Peanpunga, Udom; Ugsornrat, Kessararat; Thorlor, Panakamol; Sumithpibul, Chalermsak

    2017-09-01

    This research studied about an epoxy molding compound (EMC) floor life to reliability performance of integrated circuit (IC) package. Molding is the process for protecting the die of IC package form mechanical and chemical reaction from external environment by shaping EMC. From normal manufacturing process, the EMC is stored in the frozen at 5oC and left at around room temperature for aging time or floor life before molding process. The EMC floor life effect to its properties and reliability performance of IC package. Therefore, this work interested in varied the floor life of EMC before molding process to analyze properties of EMC such as spiral flow length, gelation time, and viscosity. In experiment, the floor life of EMC was varied to check the effect of its property to reliability performance. The EMC floor life were varied from 0 hours to 60 hours with a step of 12 hours and observed wire sweep, incomplete EMC, and delamination inside the packages for 3x3, 5x5 and 8x8 mm2 of QFN packages. The evaluation showed about clearly effect of EMC floor life to IC packaging reliability. EMC floor life is not any concern for EMC property, moldabilty, and reliability from 0 hours to 48 hours for molding process of 3x3,5x5 and 8x8 mm2 QFN packaging manufacturing

  20. Component fragility data base for reliability and probability studies

    International Nuclear Information System (INIS)

    Bandyopadhyay, K.; Hofmayer, C.; Kassier, M.; Pepper, S.

    1989-01-01

    Safety-related equipment in a nuclear plant plays a vital role in its proper operation and control, and failure of such equipment due to an earthquake may pose a risk to the safe operation of the plant. Therefore, in order to assess the overall reliability of a plant, the reliability of performance of the equipment should be studied first. The success of a reliability or a probability study depends to a great extent on the data base. To meet this demand, Brookhaven National Laboratory (BNL) has formed a test data base relating the seismic capacity of equipment specimens to the earthquake levels. Subsequently, the test data have been analyzed for use in reliability and probability studies. This paper describes the data base and discusses the analysis methods. The final results that can be directly used in plant reliability and probability studies are also presented in this paper

  1. “Weather” transit is reliable? Using AVL data to explore tram performance in Melbourne, Australia

    Directory of Open Access Journals (Sweden)

    Mahmoud Mesbah

    2015-06-01

    Full Text Available This paper uses automatic vehicle location (AVL records to investigate the effect of weather conditions on the travel time reliability of on-road rail transit, through a case study of the Melbourne streetcar (tram network. The datasets available were an extensive historical AVL dataset as well as weather observations. The sample size used in the analysis included all trips made over a period of five years (2006–2010 inclusive, during the morning peak (7 am–9 am for fifteen randomly selected radial tram routes, all traveling to the Melbourne CBD. Ordinary least square (OLS regression analysis was conducted to create a linear model, with tram travel time being the dependent variable. An alternative formulation of the model is also compared. Travel time was regressed on various weather effects including precipitation, air temperature, sea level pressure and wind speed; as well as indicator variables for weekends, public holidays and route numbers to investigate a correlation between weather condition and the on-time performance of the trams. The results indicate that only precipitation and air temperature are significant in their effect on tram travel time. The model demonstrates that on average, an additional millimeter of precipitation during the peak period adversely affects the average travel time during that period by approximately 8 s, that is, rainfall tends to increase the travel time. The effect of air temperature is less intuitive, with the model indicating that trams adhere more closely to schedule when the temperature is different in absolute terms to the mean operating conditions (taken as 15 °C.

  2. Further Development of the Assessment of Military Multitasking Performance: Iterative Reliability Testing.

    Directory of Open Access Journals (Sweden)

    Margaret M Weightman

    Full Text Available The Assessment of Military Multitasking Performance (AMMP is a battery of functional dual-tasks and multitasks based on military activities that target known sensorimotor, cognitive, and exertional vulnerabilities after concussion/mild traumatic brain injury (mTBI. The AMMP was developed to help address known limitations in post concussive return to duty assessment and decision making. Once validated, the AMMP is intended for use in combination with other metrics to inform duty-readiness decisions in Active Duty Service Members following concussion. This study used an iterative process of repeated interrater reliability testing and feasibility feedback to drive modifications to the 9 tasks of the original AMMP which resulted in a final version of 6 tasks with metrics that demonstrated clinically acceptable ICCs of > 0.92 (range of 0.92-1.0 for the 3 dual tasks and > 0.87 (range 0.87-1.0 for the metrics of the 3 multitasks. Three metrics involved in recording subject errors across 2 tasks did not achieve ICCs above 0.85 set apriori for multitasks (0.64 and above 0.90 set for dual-tasks (0.77 and 0.86 and were not used for further analysis. This iterative process involved 3 phases of testing with between 13 and 26 subjects, ages 18-42 years, tested in each phase from a combined cohort of healthy controls and Service Members with mTBI. Study findings support continued validation of this assessment tool to provide rehabilitation clinicians further return to duty assessment methods robust to ceiling effects with strong face validity to injured Warriors and their leaders.

  3. New design of engineered safety features-component control system to improve performance and reliability

    International Nuclear Information System (INIS)

    Kim, S.T.; Jung, H.W.; Lee, S.J.; Cho, C.H.; Kim, D.H.; Kim, H.

    2006-01-01

    Full text: Full text: The Engineered Safety Features-Component Control System (ESF-CCS) controls the engineered safety features of a Nuclear Power Plant such as Solenoid Operated Valves (SOV), Motor Operated Valves (MOV), pumps, dampers, etc. to mitigate the effects of a Design Basis Accident (DBA) or an abnormal operation. ESF-CCS serves as an interface system between the Plant Protection System (PPS) and remote actuation devices. ESF-CCS is composed of fault tolerant Group Controllers GC, Loop Controllers (LC), ESF-CCS Test and Interface Processor (ETIP) and Cabinet Operator Module (COM) and Control Channel Gateway (CCG) etc. GCs in each division are designed to be fully independent triple configuration, which perform system level NSSS and BOP ESFAS logic (2-out-of-4 logic and l-out-of-2 logic, respectively) making it possible to test each GC individually during normal operation. In the existing configuration, the safety-related plant component control is part of the Plant Control System (PCS) non-safety system. For increased safety and reliability, this design change incorporates this part into the LCs, and is therefore designed according to the safety-critical system procedures. The test and diagnosis capabilities of ETIP and COM are reinforced. By means of an automatic periodic test for all main functions of the system, it is possible to quickly determine an abnormal status of the system, and to decrease the elapsed time for tests, thus effectively increasing availability. ESF-CCS consists of four independent divisions (A, B, C, and D) in the Advanced Power Reactor 1400 (APR1400). One prototype division is being manufactured and will be tested

  4. Performance evaluation of aprons according to lead equipment and form types

    International Nuclear Information System (INIS)

    Kim, Ki Won; Choi, Sung Hyun; Kim, Ki Yeol; Lee, Ik Pyo; Hwang, Sun Gwang; Dong, Kyung Rae

    2017-01-01

    The apron is one of the essential protectors to reduce the exposure dose of radiological technologists. This study is to provide a guideline for purchasing the aprons with excellent performance and to help reducing the exposure dose by measuring the shielding ration and uniformity of aprons according to lead equivalent and form types. The shielding ratio of aprons were measured by using radiation generator and dosimeter. Exposure conditions were 81 kVp, 25 mAs, source to image receptor distance (SID) 100 cm and field of view (FOV) 17"×17". Exposure areas for front type and around type aprons were divided into 9 areas and for 2 pieces type aprons were divided into 3 areas of top and 4 areas of skirt. The uniformity of aprons were measured by using fluoroscopy and Image J. The 4 regions of interest (ROI) were set into acquired images and measured uniformity by measuring the standard deviation of pixel intensity in ROIs. In continuous shielding ration measurement of aprons according to exposure area, there was not statistical significance (P>0.05). In ANOVA test of aprons, there was statistical significance (P<0.01). In the results of shielding ratio, although the aprons had equal lead equivalent, there were difference in shielding ratio from 83.59% to 98.15%. In the results of uniformity, the front type aprons with equal lead equivalent indicated the similar uniformity. However, the around type and 2 pieces type apron with equal lead equivalent indicated the different uniformity each other, from 1.8 to 22.2. If the performance evaluation in this study were conducted regularly before and after purchase the aprons, the exposure does to patients and radiological technologists could be reduced

  5. Performance evaluation of aprons according to lead equipment and form types

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Won; Choi, Sung Hyun; Kim, Ki Yeol; Lee, Ik Pyo; Hwang, Sun Gwang [Dept. of Radiology, Kyung Hee University Hostpital at Gangdong, Seoul (Korea, Republic of); Dong, Kyung Rae [Dept. of of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of)

    2017-02-15

    The apron is one of the essential protectors to reduce the exposure dose of radiological technologists. This study is to provide a guideline for purchasing the aprons with excellent performance and to help reducing the exposure dose by measuring the shielding ration and uniformity of aprons according to lead equivalent and form types. The shielding ratio of aprons were measured by using radiation generator and dosimeter. Exposure conditions were 81 kVp, 25 mAs, source to image receptor distance (SID) 100 cm and field of view (FOV) 17{sup ×}17{sup .} Exposure areas for front type and around type aprons were divided into 9 areas and for 2 pieces type aprons were divided into 3 areas of top and 4 areas of skirt. The uniformity of aprons were measured by using fluoroscopy and Image J. The 4 regions of interest (ROI) were set into acquired images and measured uniformity by measuring the standard deviation of pixel intensity in ROIs. In continuous shielding ration measurement of aprons according to exposure area, there was not statistical significance (P>0.05). In ANOVA test of aprons, there was statistical significance (P<0.01). In the results of shielding ratio, although the aprons had equal lead equivalent, there were difference in shielding ratio from 83.59% to 98.15%. In the results of uniformity, the front type aprons with equal lead equivalent indicated the similar uniformity. However, the around type and 2 pieces type apron with equal lead equivalent indicated the different uniformity each other, from 1.8 to 22.2. If the performance evaluation in this study were conducted regularly before and after purchase the aprons, the exposure does to patients and radiological technologists could be reduced.

  6. Some Aspects of Psychophysiological Support of Crew Member's Performance Reliability in Space Flight

    Science.gov (United States)

    Nechaev, A. P.; Myasnikov, V. I.; Stepanova, S. I.; Isaev, G. F.; Bronnikov, S. V.

    The history of cosmonautics demonstrates many instances in which only crewmembers' intervention allowed critical situations to be resolved, or catastrophes to be prevented. However, during "crew-spacecraft" system operation human is exposed by influence of numerous flight factors, and beforehand it is very difficult to predict their effects on his functional state and work capacity. So, the incidents are known when unfavorable alterations of crewmember's psychophysiological state (PPS) provoked errors in task performance. The objective of the present investigation was to substantiate the methodological approach directed to increase reliability of a crewmember performance (human error prevention) by means of management of his/her PPS. The specific aims of the investigation were: 1) to evaluate the statistical significance of the interrelation between crew errors (CE) and crewmember's PPS, and 2) to develop the way of PPS management. At present, there is no conventional method to assess combined effect of flight conditions (microgravity, confinement, psychosocial factors, etc.) on crewmembers' PPS. For this purpose experts of the Medical Support Group (psychoneurologists and psychologists) at the Moscow Mission Control Center analyze information received during radio and TV contacts with crew. Peculiarities of behavior, motor activity, sleep, speech, mood, emotional reactions, well-being and sensory sphere, trend of dominant interests and volitional acts, signs of deprivation phenomena are considered as separate indicators of crewmember's PPS. The set of qualitative symptoms reflecting PPS alterations and corresponding to them ratings (in arbitrary units) was empirically stated for each indicator. It is important to emphasize that symptoms characterizing more powerful PPS alterations have higher ratings. Quantitative value of PPS integral parameter is calculating by adding up the ratings of all separate indicators over a day, a week, or other temporal interval (in

  7. The performance of a prototype device designed to evaluate general quality parameters of X-ray equipment

    Science.gov (United States)

    Murata, C. H.; Fernandes, D. C.; Lavínia, N. C.; Caldas, L. V. E.; Pires, S. R.; Medeiros, R. B.

    2014-02-01

    The performance of radiological equipment can be assessed using non-invasive methods and portable instruments that can analyze an X-ray beam with just one exposure. These instruments use either an ionization chamber or a state solid detector (SSD) to evaluate X-ray beam parameters. In Brazil, no such instruments are currently being manufactured; consequently, these instruments come at a higher cost to users due to importation taxes. Additionally, quality control tests are time consuming and impose a high workload on the X-ray tubes when evaluating their performance parameters. The assessment of some parameters, such as the half-value layer (HVL), requires several exposures; however, this can be reduced by using a SSD that requires only a single exposure. One such SSD uses photodiodes designed for high X-ray sensitivity without the use of scintillation crystals. This sensitivity allows one electron-hole pair to be created per 3.63 eV of incident energy, resulting in extremely high and stable quantum efficiencies. These silicon photodiodes operate by absorbing photons and generating a flow of current that is proportional to the incident power. The aim of this study was to show the response of the solid sensor PIN RD100A detector in a multifunctional X-ray analysis system that is designed to evaluate the average peak voltage (kVp), exposure time, and HVL of radiological equipment. For this purpose, a prototype board that uses four SSDs was developed to measure kVp, exposure time, and HVL using a single exposure. The reproducibility and accuracy of the results were compared to that of different X-ray beam analysis instruments. The kVp reproducibility and accuracy results were 2% and 3%, respectively; the exposure time reproducibility and accuracy results were 2% and 1%, respectively; and the HVL accuracy was ±2%. The prototype's methodology was able to calculate these parameters with appropriate reproducibility and accuracy. Therefore, the prototype can be considered

  8. Effect of Epistemic Uncertainty Modeling Approach on Decision-Making: Example using Equipment Performance Indicator

    Energy Technology Data Exchange (ETDEWEB)

    Dana Kelly; Robert Youngblood

    2012-06-01

    Quantitative risk assessments are an integral part of risk-informed regulation of current and future nuclear plants in the U.S. The Bayesian approach to uncertainty, in which both stochastic and epistemic uncertainties are represented with precise probability distributions, is the standard approach to modeling uncertainties in such quantitative risk assessments. However, there are long-standing criticisms of the Bayesian approach to epistemic uncertainty from many perspectives, and a number of alternative approaches have been proposed. Among these alternatives, the most promising (and most rapidly developing) would appear to be the concept of imprecise probability. In this paper, we employ a performance indicator example to focus the discussion. We first give a short overview of the traditional Bayesian paradigm and review some its controversial aspects, for example, issues with so-called noninformative prior distributions. We then discuss how the imprecise probability approach treats these issues and compare it with two other approaches: sensitivity analysis and hierarchical Bayes modeling. We conclude with some practical implications for risk-informed decision making.

  9. Performance Analysis of Window Type Air Conditioning with Addition of Heat Exchanger Equipment

    Directory of Open Access Journals (Sweden)

    I Ketut Gede Wirawan

    2012-11-01

    Full Text Available One manner to be used to increase refregration effect is by flowing hot refrigerant out from condensor, it is then touched with the refrigerant out from evaporator on a heat exchanger of counterflow type. Experiment was done by taking samples of pressure at suction (p1 and discharge (p2 of compressor and box temperature (Tr1, Tr2, Tr3, Tr4. By knowing of pressure at suction (p1, the enthalpy into compressor is known. By assuming the process is isentropic (compressor, isobar (condenser and evaporator, and isenthalpy (expansion valve, the enthalpy into condensor, expansion valve and evaporator were known. In 60 minutes, compression work of air conditioning with heat exchanger is 31,588 kJ/kg, and without heat exchanger is 33,796 kJ/kg. Effect refrigeration average with modification is 155,55 kJ/kg and without modification was 153,40 kJ/kg so that coefficient of performance with modification more than without modification. Air conditioning with modification had initial refrigration rate was 67,193 J/s and 0,043 J/s at the end minute, meanwhile, refrigeration without modification had cooling rate at start 66,538 J/s and 0,935 J/s at the end.

  10. PERFORMANCE EVALUATION OF sUAS EQUIPPED WITH VELODYNE HDL-32E LiDAR SENSOR

    Directory of Open Access Journals (Sweden)

    G. Jozkow

    2017-08-01

    Full Text Available The Velodyne HDL-32E laser scanner is used more frequently as main mapping sensor in small commercial UASs. However, there is still little information about the actual accuracy of point clouds collected with such UASs. This work evaluates empirically the accuracy of the point cloud collected with such UAS. Accuracy assessment was conducted in four aspects: impact of sensors on theoretical point cloud accuracy, trajectory reconstruction quality, and internal and absolute point cloud accuracies. Theoretical point cloud accuracy was evaluated by calculating 3D position error knowing errors of used sensors. The quality of trajectory reconstruction was assessed by comparing position and attitude differences from forward and reverse EKF solution. Internal and absolute accuracies were evaluated by fitting planes to 8 point cloud samples extracted for planar surfaces. In addition, the absolute accuracy was also determined by calculating point 3D distances between LiDAR UAS and reference TLS point clouds. Test data consisted of point clouds collected in two separate flights performed over the same area. Executed experiments showed that in tested UAS, the trajectory reconstruction, especially attitude, has significant impact on point cloud accuracy. Estimated absolute accuracy of point clouds collected during both test flights was better than 10 cm, thus investigated UAS fits mapping-grade category.

  11. Performance Evaluation of sUAS Equipped with Velodyne HDL-32E LiDAR Sensor

    Science.gov (United States)

    Jozkow, G.; Wieczorek, P.; Karpina, M.; Walicka, A.; Borkowski, A.

    2017-08-01

    The Velodyne HDL-32E laser scanner is used more frequently as main mapping sensor in small commercial UASs. However, there is still little information about the actual accuracy of point clouds collected with such UASs. This work evaluates empirically the accuracy of the point cloud collected with such UAS. Accuracy assessment was conducted in four aspects: impact of sensors on theoretical point cloud accuracy, trajectory reconstruction quality, and internal and absolute point cloud accuracies. Theoretical point cloud accuracy was evaluated by calculating 3D position error knowing errors of used sensors. The quality of trajectory reconstruction was assessed by comparing position and attitude differences from forward and reverse EKF solution. Internal and absolute accuracies were evaluated by fitting planes to 8 point cloud samples extracted for planar surfaces. In addition, the absolute accuracy was also determined by calculating point 3D distances between LiDAR UAS and reference TLS point clouds. Test data consisted of point clouds collected in two separate flights performed over the same area. Executed experiments showed that in tested UAS, the trajectory reconstruction, especially attitude, has significant impact on point cloud accuracy. Estimated absolute accuracy of point clouds collected during both test flights was better than 10 cm, thus investigated UAS fits mapping-grade category.

  12. EFFECT OF LUBRICANT CONTAMINATION ON THE PERFORMANCE AND RELIABILITY OF HEAT PUMPS CHARGED WITH R-407C.

    Science.gov (United States)

    The report gives results of the development of new data that can be used to determine the effect of mineral oil contamination on the reliability of a heat pump system operating with a new hydrofluorocarbon mixture and polyol ester lubricant, to assess any performance degradation ...

  13. The Validity and Reliability of the Gymaware Linear Position Transducer for Measuring Counter-Movement Jump Performance in Female Athletes

    Science.gov (United States)

    O'Donnell, Shannon; Tavares, Francisco; McMaster, Daniel; Chambers, Samuel; Driller, Matthew

    2018-01-01

    The current study aimed to assess the validity and test-retest reliability of a linear position transducer when compared to a force plate through a counter-movement jump in female participants. Twenty-seven female recreational athletes (19 ± 2 years) performed three counter-movement jumps simultaneously using the linear position transducer and…

  14. Proceedings of the 1998 Photovoltaic Performance and Reliability Workshop; Cocoa Beach, Florida; November 3-5, 1998

    Energy Technology Data Exchange (ETDEWEB)

    Kroposki, B.

    1998-12-17

    This proceedings is the compilation of all papers presented at the 11th PV Performance and Reliability Workshop held at the Doubletree Hotel in Cocoa Beach, Florida, on November 3-5, 1998. The workshop was hosted by the Florida Solar Energy Center. This year's workshop included presentations from 29 speakers and had 110 attendees.

  15. Experimental Investigation of Thermohydraulic Performance of a Rectangular Solar Air Heater Duct Equipped with V-Shaped Perforated Blocks

    Directory of Open Access Journals (Sweden)

    Tabish Alam

    2014-01-01

    Full Text Available This paper presents the thermohydraulic performance of rectangular solar air heater duct equipped with V-shaped rectangular perforated blocks attached to the heated surface. The V-shaped perforated blocks are tested for downstream (V-down to the air flow at Reynolds number from 2000 to 20000. The perforated blocks have relative pitch ratio (P/e from 4 to 12, relative blockage height ratio (e/H from 0.4 to 1.0, and open area ration from 5% to 25% at a fixed value of angle of attack of 60∘ in a rectangular duct having duct aspect ratio (W/H of 12. Thermohydraulic performance is compared at different geometrical parameters of V-shaped perforated blocks for equal pumping power which shows that maximum performance is observed at a relative pitch of 8, relative rib height of 0.8, and open area ration of 20%. It is also observed that the performance of V-shaped perforated blocks was better than transverse-perforated blocks.

  16. Performance Evaluation of an Active Solar Dryer Equipped with an Auxilliary Electrical Heater and Heat Recovery System

    International Nuclear Information System (INIS)

    Pourghasemi Ranjbar, M.; Alavi Naeini, N.; Mortezapour, H.

    2016-01-01

    Drying is a very sophisticated process which consumes a large amount of energy. Solar energy can be used as an alternative or supplementary energy source to fossil fuels. Solar dryers are common ways for saving fossil fuel consumption during agricultural products drying. In this study, the performance of an active solar dryer equipped with an energy recovery system was investigated at three levels of drying air temperature. The results showed that the energy recovery system was able to increase inlet air temperature by 16.8, 18.5 and 18.9 ° C at drying temperatures of 55, 65 and 75 ℃, respectively. Meanwhile 47.8, 42.9 and 40.9 percents of the dryer exhaust air energy were recovered respectively at these conditions which subsequently led to a reduction of 30.7, 19.2 and 14.7 percents in electrical heater energy consumption.

  17. Overall Key Performance Indicator to Optimizing Operation of High-Pressure Homogenizers for a Reliable Quantification of Intracellular Components in Pichia pastoris.

    Science.gov (United States)

    Garcia-Ortega, Xavier; Reyes, Cecilia; Montesinos, José Luis; Valero, Francisco

    2015-01-01

    The most commonly used cell disruption procedures may present lack of reproducibility, which introduces significant errors in the quantification of intracellular components. In this work, an approach consisting in the definition of an overall key performance indicator (KPI) was implemented for a lab scale high-pressure homogenizer (HPH) in order to determine the disruption settings that allow the reliable quantification of a wide sort of intracellular components. This innovative KPI was based on the combination of three independent reporting indicators: decrease of absorbance, release of total protein, and release of alkaline phosphatase activity. The yeast Pichia pastoris growing on methanol was selected as model microorganism due to it presents an important widening of the cell wall needing more severe methods and operating conditions than Escherichia coli and Saccharomyces cerevisiae. From the outcome of the reporting indicators, the cell disruption efficiency achieved using HPH was about fourfold higher than other lab standard cell disruption methodologies, such bead milling cell permeabilization. This approach was also applied to a pilot plant scale HPH validating the methodology in a scale-up of the disruption process. This innovative non-complex approach developed to evaluate the efficacy of a disruption procedure or equipment can be easily applied to optimize the most common disruption processes, in order to reach not only reliable quantification but also recovery of intracellular components from cell factories of interest.

  18. A criterion of the performance of thermometric systems of high metrological reliability

    International Nuclear Information System (INIS)

    Sal'nikov, N.L.; Filimonov, E.V.

    1995-01-01

    Monitoring temperature regimes is an important part of ensuring the operational safety of a nuclear power plant. Therefore, high standards are imposed upon the reliability of the primary information on the heat field of the object obtained from different sensors, and it is urgent to develop methods of evaluating the metrological reliability of these sensors. THe main sources of thermometric information at nuclear power plants are contact temperature sensors, the most widely used of these being thermoelectric converters (TEC) and thermal resistance converters (TRC)

  19. An Impact of Thermodynamic Processes in Human Bodies on Performance Reliability of Individuals

    Directory of Open Access Journals (Sweden)

    Smalko Zbigniew

    2015-01-01

    Full Text Available The article presents the problem of the influence of thermodynamic factors on human fallibility in different zones of thermal discomfort. Describes the processes of energy in the human body. Been given a formal description of the energy balance of the human body thermoregulation. Pointed to human reactions to temperature changes of internal and external environment, including reactions associated with exercise. The methodology to estimate and determine the reliability of indicators of human basal acting in different zones of thermal discomfort. The significant effect of thermodynamic factors on the reliability and security ofperson.

  20. Improvement of Steam Turbine Operational Performance and Reliability with using Modern Information Technologies

    Science.gov (United States)

    Brezgin, V. I.; Brodov, Yu M.; Kultishev, A. Yu

    2017-11-01

    The report presents improvement methods review in the fields of the steam turbine units design and operation based on modern information technologies application. In accordance with the life cycle methodology support, a conceptual model of the information support system during life cycle main stages (LC) of steam turbine unit is suggested. A classifying system, which ensures the creation of sustainable information links between the engineer team (manufacture’s plant) and customer organizations (power plants), is proposed. Within report, the principle of parameterization expansion beyond the geometric constructions at the design and improvement process of steam turbine unit equipment is proposed, studied and justified. The report presents the steam turbine unit equipment design methodology based on the brand new oil-cooler design system that have been developed and implemented by authors. This design system combines the construction subsystem, which is characterized by extensive usage of family tables and templates, and computation subsystem, which includes a methodology for the thermal-hydraulic zone-by-zone oil coolers design calculations. The report presents data about the developed software for operational monitoring, assessment of equipment parameters features as well as its implementation on five power plants.

  1. Effects of Differential Item Functioning on Examinees' Test Performance and Reliability of Test

    Science.gov (United States)

    Lee, Yi-Hsuan; Zhang, Jinming

    2017-01-01

    Simulations were conducted to examine the effect of differential item functioning (DIF) on measurement consequences such as total scores, item response theory (IRT) ability estimates, and test reliability in terms of the ratio of true-score variance to observed-score variance and the standard error of estimation for the IRT ability parameter. The…

  2. Human reliability

    International Nuclear Information System (INIS)

    Embrey, D.E.

    1987-01-01

    Concepts and techniques of human reliability have been developed and are used mostly in probabilistic risk assessment. For this, the major application of human reliability assessment has been to identify the human errors which have a significant effect on the overall safety of the system and to quantify the probability of their occurrence. Some of the major issues within human reliability studies are reviewed and it is shown how these are applied to the assessment of human failures in systems. This is done under the following headings; models of human performance used in human reliability assessment, the nature of human error, classification of errors in man-machine systems, practical aspects, human reliability modelling in complex situations, quantification and examination of human reliability, judgement based approaches, holistic techniques and decision analytic approaches. (UK)

  3. Reliability Calculations

    DEFF Research Database (Denmark)

    Petersen, Kurt Erling

    1986-01-01

    Risk and reliability analysis is increasingly being used in evaluations of plant safety and plant reliability. The analysis can be performed either during the design process or during the operation time, with the purpose to improve the safety or the reliability. Due to plant complexity and safety...... and availability requirements, sophisticated tools, which are flexible and efficient, are needed. Such tools have been developed in the last 20 years and they have to be continuously refined to meet the growing requirements. Two different areas of application were analysed. In structural reliability probabilistic...... approaches have been introduced in some cases for the calculation of the reliability of structures or components. A new computer program has been developed based upon numerical integration in several variables. In systems reliability Monte Carlo simulation programs are used especially in analysis of very...

  4. Study of redundant Models in reliability prediction of HXMT's HES

    International Nuclear Information System (INIS)

    Wang Jinming; Liu Congzhan; Zhang Zhi; Ji Jianfeng

    2010-01-01

    Two redundant equipment structures of HXMT's HES are proposed firstly, the block backup and dual system cold-redundancy. Then prediction of the reliability is made by using parts count method. Research of comparison and analysis is also performed on the two proposals. A conclusion is drawn that a higher reliability and longer service life could be offered by taking a redundant equipment structure of block backup. (authors)

  5. Power Doppler ultrasonography and synovitis: correlating ultrasound imaging with histopathological findings and evaluating the performance of ultrasound equipments.

    Science.gov (United States)

    Koski, J M; Saarakkala, S; Helle, M; Hakulinen, U; Heikkinen, J O; Hermunen, H

    2006-12-01

    To examine the validity of power Doppler ultrasound imaging to identify synovitis, using histopathology as gold standard, and to assess the performance of ultrasound equipments. 44 synovial sites in small and large joints, bursae and tendon sheaths were depicted with ultrasound. A synovial biopsy was performed on the site depicted and a synovial sample was taken for histopathological evaluation. The performance of three ultrasound devices was tested using flow phantoms. A positive Doppler signal was detected in 29 of 35 (83%) of the patients with active histological inflammation. In eight additional samples, histological examination showed other pathological synovial findings and a Doppler signal was detected in five of them. No significant correlation was found between the amount of Doppler signal and histological synovitis score (r = 0.239, p = NS). The amount of subsynovial infiltration of polymorphonuclear leucocytes and surface fibrin correlated significantly with the amount of power Doppler signal: r = 0.397 (pultrasound devices differed in showing the smallest detectable flow. A negative Doppler signal does not exclude the possibility of synovitis. A positive Doppler signal in the synovium is an indicator of an active synovial inflammation in patients. A Doppler signal does not correlate with the extent of the inflammation and it can also be seen in other synovial reactions. It is important that the quality measurements of ultrasound devices are reported, because the results should be evaluated against the quality of the device used.

  6. [Hydrotherapy equipment].

    Science.gov (United States)

    Tsibikov, V B; Ragozin, S I; Mikheeva, L V

    1985-01-01

    A flow-chart is developed demonstrating the relation between medical and prophylactic institutions within the organizational structure of the rehabilitation system and main types of rehabilitation procedures. In order to ascertain the priority in equipping rehabilitation services with adequate hardware the special priority criterion is introduced. The highest priority is assigned to balneotherapeutic and fangotherapeutic services. Based on the operation-by-operation analysis of clinical processes related to service and performance of balneologic procedures the preliminary set of clinical devices designed for baths, basins and showers in hospitals and rehabilitation departments is defined in a generalized form.

  7. Intra-rater reliability and agreement of muscle strength, power and functional performance measures in patients with hip osteoarthritis

    DEFF Research Database (Denmark)

    Bieler, Theresa; Magnusson, S Peter; Kjær, Michael

    2014-01-01

    OBJECTIVE: To investigate the reliability and agreement of measures of lower extremity muscle strength, power and functional performance in patients with hip osteoarthritis at different time intervals, and to compare these with the same measures in healthy peers. DESIGN: Intra-rater test...... extensor power, and functional performance (8-foot Up & Go, stair climbing, chair stand and 6-min walk) were measured in patients, and quadriceps strength, leg extensor power and functional performance were measured in healthy peers. Systematic error, reliability and agreement were calculated. RESULTS......-retest separated by 1, 2, or 2.5 weeks in patients, and 1 week in healthy peers. SUBJECTS: Patients with hip osteoarthritis (age range 61-83 years) with 1 (n = 37), 2 (n = 35), or 2.5 weeks (n = 15) between tests, and 35 healthy peers (age range 63-82 years). METHODS: Maximal isometric hip and thigh strength, leg...

  8. The Functional Test for Agility Performance is a Reliable Quick Decision-Making Test for Skilled Water Polo Players

    Directory of Open Access Journals (Sweden)

    Tucher Guilherme

    2015-06-01

    Full Text Available The reliability of the Functional Test for Agility Performance has only been evaluated in water polo players in a small group of novice athletes. Thus, the aim of this study was to evaluate the reliability of the Functional Test for Agility Performance in skilled water polo players. Forty-two athletes (17.81 ± 3.24 years old with a minimum of 5 years of competitive experience (7.05 ± 2.84 years and playing at the national or international level were evaluated. The Functional Test for Agility Performance is characterized as a specific open decision-making test where a tested player moves as quickly as possible in accordance to a pass made by another player. The time spent in the test was measured by two experienced coaches. Descriptive statistics, repeated measures analysis of variance (ANOVA, 95% limit of agreement (LOA, intraclass correlation coefficient (ICC and standard error of measurements (SEM were used for data analysis. Athletes completed the Functional Test for Agility Performance in 4.15 0.47 s. The ICC value was 0.87 (95% IC = 0.80-0.92. The SEM varied between 0.24 and 0.38 s. The LOA was 1.20 s and the CV average considering each individual trial was 6%. The Functional Test for Agility Performance was shown to be a reliable quick decision-making test for skilled water polo players.

  9. Research on Application of FMECA in Missile Equipment Maintenance Decision

    Science.gov (United States)

    Kun, Wang

    2018-03-01

    Fault mode effects and criticality analysis (FMECA) is a method widely used in engineering. Studying the application of FMEA technology in military equipment maintenance decision-making, can help us build a better equipment maintenance support system, and increase the using efficiency of weapons and equipment. Through Failure Modes, Effects and Criticality Analysis (FMECA) of equipment, known and potential failure modes and their causes are found out, and the influence on the equipment performance, operation success, personnel security are determined. Furthermore, according to the synthetical effects of the severity of effects and the failure probability, possible measures for prevention and correction are put forward. Through replacing or adjusting the corresponding parts, corresponding maintenance strategy is decided for preventive maintenance of equipment, which helps improve the equipment reliability.

  10. Reliability and validity of videotaped functional performance tests in ACL-injured subjects

    DEFF Research Database (Denmark)

    von Porat, Anette; Holmström, Eva; Roos, Ewa

    2008-01-01

    BACKGROUND AND PURPOSE: In clinical practice, visual observation is often used to determine functional impairment and to evaluate treatment following a knee injury. The aim of this study was to evaluate the reliability and validity of observational assessments of knee movement pattern quality......, crossover hop on one leg and one-leg hop. The videos were observed by four physiotherapists, and the knee movement pattern quality, a feature of the loading strategy of the lower extremity, was scored on an 11-point rating scale. To assess the criterion validity, the observational rating was correlated...... obtained between the observers' assessment and knee flexion angle, r = 0.37-0.61. The crossover hop test or one-leg hop test was ranked as the most useful test in 172 of 192 occasions (90%) when assessing knee function. CONCLUSION: The moderate to good inter-observer reliability and the moderate criterion...

  11. Space Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1998-01-01

    The performance evaluation of space heating equipment for a geothermal application is generally considered from either of two perspectives: (a) selecting equipment for installation in new construction, or (b) evaluating the performance and retrofit requirements of an existing system. With regard to new construction, the procedure is relatively straightforward. Once the heating requirements are determined, the process need only involve the selection of appropriately sized hot water heating equipment based on the available water temperature. It is important to remember that space heating equipment for geothermal applications is the same equipment used in non-geothermal applications. What makes geothermal applications unique is that the equipment is generally applied at temperatures and flow rates that depart significantly from traditional heating system design. This chapter presents general considerations for the performance of heating equipment at non-standard temperature and flow conditions, retrofit of existing systems, and aspects of domestic hot water heating.

  12. Applying the High Reliability Health Care Maturity Model to Assess Hospital Performance: A VA Case Study.

    Science.gov (United States)

    Sullivan, Jennifer L; Rivard, Peter E; Shin, Marlena H; Rosen, Amy K

    2016-09-01

    The lack of a tool for categorizing and differentiating hospitals according to their high reliability organization (HRO)-related characteristics has hindered progress toward implementing and sustaining evidence-based HRO practices. Hospitals would benefit both from an understanding of the organizational characteristics that support HRO practices and from knowledge about the steps necessary to achieve HRO status to reduce the risk of harm and improve outcomes. The High Reliability Health Care Maturity (HRHCM) model, a model for health care organizations' achievement of high reliability with zero patient harm, incorporates three major domains critical for promoting HROs-Leadership, Safety Culture, and Robust Process Improvement ®. A study was conducted to examine the content validity of the HRHCM model and evaluate whether it can differentiate hospitals' maturity levels for each of the model's components. Staff perceptions of patient safety at six US Department of Veterans Affairs (VA) hospitals were examined to determine whether all 14 HRHCM components were present and to characterize each hospital's level of organizational maturity. Twelve of the 14 components from the HRHCM model were detected; two additional characteristics emerged that are present in the HRO literature but not represented in the model-teamwork culture and system-focused tools for learning and improvement. Each hospital's level of organizational maturity could be characterized for 9 of the 14 components. The findings suggest the HRHCM model has good content validity and that there is differentiation between hospitals on model components. Additional research is needed to understand how these components can be used to build the infrastructure necessary for reaching high reliability.

  13. The Impact of Automation Reliability and Operator Fatigue on Performance and Reliance

    Science.gov (United States)

    2016-09-23

    Cummings et al., 2007). Automation designed to assist operators in overload situations may promote operator disengagement during periods of low...Calhoun et al., 2011). This testbed offers several tasks designed to emulate the cognitive demands that an operator managing multiple UAVs is likely...reliable (Cronbach’s α = 0.94) measure of affective and cognitive components of trust in automation. Items gauge confidence in an automation and

  14. THERMAL AND THERMO-MECHANICAL CHARACTERISTICS OF CRYOGENIC MICROCOOLER FOR OPTIMUM PERFORMANCE AND RELIABILITY

    Science.gov (United States)

    2017-10-19

    reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of...contracted fundamental research deemed exempt from public affairs security and policy review in accordance with SAF/AQR memorandum dated 10 Dec 08 and AFRL...subjected to cryogenic operating conditions was assessed by proposing a hierarchical physics -of-failure-based reliability assessment model. 15. SUBJECT

  15. Reliability testing of failed fuel location system

    International Nuclear Information System (INIS)

    Vieru, G.

    1996-01-01

    This paper presents the experimental reliability tests performed in order to prove the reliability parameters for Failed Fuel Location System (FFLS), equipment used to detect in which channel of a particular heat transport loop a fuel failure is located, and to find in which channel what particular bundle pair is failed. To do so, D20 samples from each reactor channel are sequentially monitored to detect a comparatively high level of delayed neutron activity. 15 refs, 8 figs, 2 tabs

  16. Power electronics reliability analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Mark A.; Atcitty, Stanley

    2009-12-01

    This report provides the DOE and industry with a general process for analyzing power electronics reliability. The analysis can help with understanding the main causes of failures, downtime, and cost and how to reduce them. One approach is to collect field maintenance data and use it directly to calculate reliability metrics related to each cause. Another approach is to model the functional structure of the equipment using a fault tree to derive system reliability from component reliability. Analysis of a fictitious device demonstrates the latter process. Optimization can use the resulting baseline model to decide how to improve reliability and/or lower costs. It is recommended that both electric utilities and equipment manufacturers make provisions to collect and share data in order to lay the groundwork for improving reliability into the future. Reliability analysis helps guide reliability improvements in hardware and software technology including condition monitoring and prognostics and health management.

  17. Analyzing Reliability and Performance Trade-Offs of HLS-Based Designs in SRAM-Based FPGAs Under Soft Errors

    Science.gov (United States)

    Tambara, Lucas Antunes; Tonfat, Jorge; Santos, André; Kastensmidt, Fernanda Lima; Medina, Nilberto H.; Added, Nemitala; Aguiar, Vitor A. P.; Aguirre, Fernando; Silveira, Marcilei A. G.

    2017-02-01

    The increasing system complexity of FPGA-based hardware designs and shortening of time-to-market have motivated the adoption of new designing methodologies focused on addressing the current need for high-performance circuits. High-Level Synthesis (HLS) tools can generate Register Transfer Level (RTL) designs from high-level software programming languages. These tools have evolved significantly in recent years, providing optimized RTL designs, which can serve the needs of safety-critical applications that require both high performance and high reliability levels. However, a reliability evaluation of HLS-based designs under soft errors has not yet been presented. In this work, the trade-offs of different HLS-based designs in terms of reliability, resource utilization, and performance are investigated by analyzing their behavior under soft errors and comparing them to a standard processor-based implementation in an SRAM-based FPGA. Results obtained from fault injection campaigns and radiation experiments show that it is possible to increase the performance of a processor-based system up to 5,000 times by changing its architecture with a small impact in the cross section (increasing up to 8 times), and still increasing the Mean Workload Between Failures (MWBF) of the system.

  18. Attentional and visual demands for sprint performance in non-fatigued and fatigued conditions: reliability of a repeated sprint test

    Directory of Open Access Journals (Sweden)

    Diercks Ron L

    2010-05-01

    Full Text Available Abstract Background Physical performance measures are widely used to assess physical function, providing information about physiological and biomechanical aspects of motor performance. However they do not provide insight into the attentional and visual demands for motor performance. A figure-of-eight sprint test was therefore developed to measure the attentional and visual demands for repeated-sprint performance. The aims of the study were: 1 to assess test-retest reliability of the figure-of-eight sprint test, and 2 to study the attentional and visual demands for sprint performance in a non-fatigued and fatigued condition. Methods Twenty-seven healthy athletes were included in the study. To determine test-retest reliability, a subgroup of 19 athletes performed the figure-of-eight sprint test twice. The figure-of-eight sprint test consisted of nine 30-second sprints. The sprint test consisted of three test parts: sprinting without any restriction, with an attention-demanding task, and with restricted vision. Increases in sprint times with the attention-demanding task or restricted vision are reflective of the attentional and visual demands for sprinting. Intraclass correlation coefficients (ICCs and mean difference between test and retest with 95% confidence limits (CL were used to assess test-retest reliability. Repeated-measures ANOVA were used for comparisons between the sprint times and fatigue measurements of the test parts in both a non-fatigued and fatigued condition. Results The figure-of-eight sprint test showed good test-retest reliability, with ICCs ranging from 0.75 to 0.94 (95% CL: 0.40-0.98. Zero lay within the 95% CL of the mean differences, indicating that no bias existed between sprint performance at test and retest. Sprint times during the test parts with attention-demanding task (P = 0.01 and restricted vision (P Conclusions High ICCs and the absence of systematic variation indicate good test-retest reliability of the figure

  19. The application and practice of predictive maintenance at CANDU equipment management

    International Nuclear Information System (INIS)

    Yu Guangting

    2014-01-01

    The equipment in Qinshan CANDU unit is characterized by large number and complex structure. Some equipment failure has no relation with the operation time, it is impossible to avoid the failure of these equipment only by periodical maintenance. To improve the equipment reliability, increase the equipment usability and decrease the maintenance cost, for important equipment related to nuclear safety and generating electricity, it is required to perform condition monitoring and the predictive maintenance (PdM). According to different characteristics of equipment, it is required to use suitable equipment condition monitoring method, content and frequency. In this way, some potential equipment failure can be found, preventive maintenance can be arranged in advance, and equipment maintenance management can be optimized. (author)

  20. 40 CFR Appendix B1 to Subpart F of... - Performance of Refrigerant Recovery, Recycling and/or Reclaim Equipment

    Science.gov (United States)

    2010-07-01

    ... Refrigeration Institute Standard 740-1993. Refrigerant Recovery/Recycling Equipment Section 1. Purpose 1..., Recycling and/or Reclaim Equipment B1 Appendix B1 to Subpart F of Part 82 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Recycling...

  1. Performance, compliance and reliability of Waste stabilization pond: Effluent discharge quality and environmental protection agency standards in Ghana

    DEFF Research Database (Denmark)

    Owusu-Ansah, Emmanuel de-Graft Johnson; Sampson, Angelina; Amponsah, Samuel K.

    2015-01-01

    function to establish the relationship between the statistical coefficient of variation and the coefficient of reliability based on rth moment about the origin in the moment of generation function to generate the functions of the mean and standard deviation, properties of the standard Z normal distribution...... were used to establish the coefficient of reliability relationship depending on the coefficient of variation influenced by the standard of deviation. Discharge values of Physico-chemical Parameters measured from the WSP were found be performing acceptably based on the EPA standards, whereas only four......Measuring performance has been arguerably, one of the metric with many facets with different school of thoughts, as there exist different approaches of measuring it. Several of the existing approaches measure such metric by comparison with standards esherined in policy documents and as a result...

  2. Effect of Sensors on the Reliability and Control Performance of Power Circuits in the Web of Things (WoT

    Directory of Open Access Journals (Sweden)

    Sungwoo Bae

    2016-09-01

    Full Text Available In order to realize a true WoT environment, a reliable power circuit is required to ensure interconnections among a range of WoT devices. This paper presents research on sensors and their effects on the reliability and response characteristics of power circuits in WoT devices. The presented research can be used in various power circuit applications, such as energy harvesting interfaces, photovoltaic systems, and battery management systems for the WoT devices. As power circuits rely on the feedback from voltage/current sensors, the system performance is likely to be affected by the sensor failure rates, sensor dynamic characteristics, and their interface circuits. This study investigated how the operational availability of the power circuits is affected by the sensor failure rates by performing a quantitative reliability analysis. In the analysis process, this paper also includes the effects of various reconstruction and estimation techniques used in power processing circuits (e.g., energy harvesting circuits and photovoltaic systems. This paper also reports how the transient control performance of power circuits is affected by sensor interface circuits. With the frequency domain stability analysis and circuit simulation, it was verified that the interface circuit dynamics may affect the transient response characteristics of power circuits. The verification results in this paper showed that the reliability and control performance of the power circuits can be affected by the sensor types, fault tolerant approaches against sensor failures, and the response characteristics of the sensor interfaces. The analysis results were also verified by experiments using a power circuit prototype.

  3. "Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia".

    Science.gov (United States)

    Olsen, Cecilie Fromholt; Bergland, Astrid

    2017-06-09

    The purpose of the study was to establish the test-retest reliability of the Norwegian version of the Short Physical Performance Battery (SPPB). This was a cross- sectional reliability study. A convenience sample of 61 older adults with a mean age of 88.4(8.1) was tested by two different physiotherapists at two time points. The mean time interval between tests was 2.5 days. The Intraclass Correlation Coefficient model 3.1 (ICC, 3.1) with 95% confidence intervals as well as the weighted Kappa (K) were used as measures of relative reliability. The Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC) were used to measure absolute reliability. The results were also analyzed for a subgroup of 24 older people with dementia. The ICC reflected high relative reliability for the SPPB summary score and the 4 m walk test (4mwt), both for the total sample (ICC = 0.92, and 0.91 respectively)) and for the subgroup with dementia (ICC = 0.84 and 0.90 respectively). Furthermore, weighted Ks for the SPPB subscales were 0.64 for the chair stand, 0.80 for gait and 0.52 for balance for the total sample and almost identical for the subgroup with dementia. MDC-values at the 95% confidence intervals (MDC95) were calculated at 0.8 for the total score of SPPB and 0.39 m/s for the 4mwt in the total sample. For the subgroup with dementia MDC95 was 1.88 for the total score of SPPB and 0.28 m/s for 4mwt. The SPPB total score and the timed walking test showed overall high relative and absolute reliability for the total sample indicating that the Norwegian version of the SPPB is reliable when used by trained physiotherapists with older people. The reliability of the Norwegian SPPB in older people with dementia seems high, but due to a small sample size this needs further investigation.

  4. Ball-Sport Endurance and Sprint Test (BEAST90): validity and reliability of a 90-minute soccer performance test.

    Science.gov (United States)

    Williams, Jeremy D; Abt, Grant; Kilding, Andrew E

    2010-12-01

    The aim of this study was to determine the validity and reliability of a 90-minute soccer performance test: Ball-sport Endurance and Sprint Test (BEAST90). Fifteen healthy male amateur soccer players participated and attended 5 testing sessions over a 10-day period to perform physiologic and soccer-specific assessments. This included familiarization sessions and 2 full trials of the BEAST90, separated by 7 days. The total 90-minute distance, mean percent peak heart rate (HRpeak), and estimated percent peak oxygen uptake of the BEAST90 were 8,097 ± 458 m, 85 ± 5% and 82 ± 14%, respectively. Measures obtained from trial 1 and trial 2 were not significantly different (p > 0.05). Reliability of measures over 90 minutes ranged from 0.9-25.5% (% typical error). The BEAST90 protocol replicated soccer match play in terms of time, movement patterns, physical demands (volume and intensity), distances, and mean and HRpeak values, as well as having an aerobic load similar to that observed during a soccer match. Reproducibility of key physical measures during the BEAST90 were mostly high, suggesting good reliability. The BEAST90 could be used in studies that wish to determine the effects of training or nutritional interventions on prolonged intermittent physical performance.

  5. Effects of variable loads on equipment and cogeneration cycles performance; Influencia da variacao da carga no rendimento de equipamentos e ciclos de co-geracao

    Energy Technology Data Exchange (ETDEWEB)

    Ernst, Mario A.B.; Balestieri, Jose A.P. [UNESP, Guaratingueta, SP (Brazil). Escola de Engenharia. Dept. de Engenharia Mecanica]. E-mails: basulto1@uol.com.br; basulto@feg.unesp.br; perella@feg.unesp.br

    2000-07-01

    This article presents some aspects relative to the effects of changing loads on steam.generators and turbines. When the equipment solicitation varies due to industrial process demand changes, the equipment work in off-design point, altering its efficiency and the specific fuel rate. This work do not look for a detailed and exhaustive determination of the performance variation with the load but shows that in the selection of equipment this variation can have effects over the consume and the costs. In the present article it is assumed that the load variations are known, and the effects on the equipment efficiency were took from the correlated literature. An example of a Rankine cycle and other of a Brayton cycle are discussed, altering the operational conditions estimating the operating cost for each case. (author)

  6. Performance and Benchmarking of Multisurface UHF RFID Tags for Readability and Reliability

    Directory of Open Access Journals (Sweden)

    Joshua Bolton

    2017-01-01

    Full Text Available As the price of passive radio frequency identification (RFID tags continues to decrease, more and more companies are considering item-level tagging. Although the use of RFID is simple, its proper application should be studied to achieve maximum efficiency and utilization in the industry. This paper is intended to demonstrate the test results of various multisurface UHF tags from different manufacturers for their readability under varying conditions such as orientation of tags with respect to reader, distance of tag from the reader, and materials used for embedding tags. These conditions could affect the reliability of RFID systems used for varied applications. In this paper, we implement a Design for Six Sigma Research (DFSS-R methodology that allows for reliability testing of RFID systems. In this paper, we have showcased our results about the benchmarking of UHF RFID tags and have put forward an important observation about the blind spots observed at different distances and orientations along different surfaces, which is primarily due to the polarity of the antenna chosen.

  7. Reliability analysis of repairable multi-state system with common bus performance sharing

    International Nuclear Information System (INIS)

    Yu, Huan; Yang, Jun; Mo, Huadong

    2014-01-01

    In this paper, an instantaneous availability model for repairable multi-state system (MSS) with common bus performance sharing is proposed. The repairable MSS consists of some multi-state units and a common bus performance redistribution system. Each unit in the system has several performance levels and must satisfy its individual random demand. A unit can transmit the surplus performance to other units in real time through the common bus performance redistribution system, if it has a performance that exceeds its demand. The entire system fails if the demand of any unit is not satisfied. A new method based on the combination of the stochastic process method and the universal generating function technique is suggested to evaluate the instantaneous availability and the mean instantaneous performance deficiency of the proposed repairable MSS. Two examples are given for applications in the end

  8. Reliability Engineering

    CERN Document Server

    Lazzaroni, Massimo

    2012-01-01

    This book gives a practical guide for designers and users in Information and Communication Technology context. In particular, in the first Section, the definition of the fundamental terms according to the international standards are given. Then, some theoretical concepts and reliability models are presented in Chapters 2 and 3: the aim is to evaluate performance for components and systems and reliability growth. Chapter 4, by introducing the laboratory tests, puts in evidence the reliability concept from the experimental point of view. In ICT context, the failure rate for a given system can be

  9. Performance and Reliability of Bonded Interfaces for High-Temperature Packaging

    Energy Technology Data Exchange (ETDEWEB)

    Paret, Paul P [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-02

    Sintered silver has proven to be a promising candidate for use as a die-attach and substrate-attach material in automotive power electronics components. It holds promise of greater reliability than lead-based and lead-free solders, especially at higher temperatures (>200 degrees C). Accurate predictive lifetime models of sintered silver need to be developed and its failure mechanisms thoroughly characterized before it can be deployed as a die-attach or substrate-attach material in wide-bandgap device-based packages. Mechanical characterization tests that result in stress-strain curves and accelerated tests that produce cycles-to-failure result will be conducted. Also, we present a finite element method (FEM) modeling methodology that can offer greater accuracy in predicting the failure of sintered silver under accelerated thermal cycling. A fracture mechanics-based approach is adopted in the FEM model, and J-integral/thermal cycle values are computed.

  10. Review of the human reliability analysis performed for Empire State Electric Energy Research Corporation

    International Nuclear Information System (INIS)

    Swart, D.; Banz, I.

    1985-01-01

    The Empire State Electric Energy Research Corporation (ESEERCO) commissioned Westinghouse to conduct a human reliability analysis to identify and quantify human error probabilities associated with operator actions for four specific events which may occur in light water reactors: loss of coolant accident, steam generator tube rupture, steam/feed line break, and stuck open pressurizer spray valve. Human Error Probabilities (HEPs) derived from Swain's Technique for Human Error Rate Prediction (THERP) were compared to data obtained from simulator exercises. A correlation was found between the HEPs derived from Swain and the results of the simulator data. The results of this study provide a unique insight into human factors analysis. The HEPs obtained from such probabilistic studies can be used to prioritize scenarios for operator training situations, and thus improve the correlation between simulator exercises and real control room experiences

  11. Demands placed on waste package performance testing and modeling by some general results on reliability analysis

    International Nuclear Information System (INIS)

    Chesnut, D.A.

    1991-09-01

    Waste packages for a US nuclear waste repository are required to provide reasonable assurance of maintaining substantially complete containment of radionuclides for 300 to 1000 years after closure. The waiting time to failure for complex failure processes affecting engineered or manufactured systems is often found to be an exponentially-distributed random variable. Assuming that this simple distribution can be used to describe the behavior of a hypothetical single barrier waste package, calculations presented in this paper show that the mean time to failure (the only parameter needed to completely specify an exponential distribution) would have to be more than 10 7 years in order to provide reasonable assurance of meeting this requirement. With two independent barriers, each would need to have a mean time to failure of only 10 5 years to provide the same reliability. Other examples illustrate how multiple barriers can provide a strategy for not only achieving but demonstrating regulatory compliance

  12. The reliability of language performance measurement in language sample analysis of children aged 5-6 years

    Directory of Open Access Journals (Sweden)

    Zahra Soleymani

    2014-04-01

    Full Text Available Background and Aim: The language sample analysis (LSA is more common in other languages than Persian to study language development and assess language pathology. We studied some psychometric properties of language sample analysis in this research such as content validity of written story and its pictures, test-retest reliability, and inter-rater reliability.Methods: We wrote a story based on Persian culture from Schneider’s study. The validity of written story and drawn pictures was approved by experts. To study test-retest reliability, 30 children looked at the pictures and told their own story twice with 7-10 days interval. Children generated the story themselves and tester did not give any cue about the story. Their audio-taped story was transcribed and analyzed. Sentence and word structures were detected in the analysis.Results: Mean of experts' agreement with the validity of written story was 92.28 percent. Experts scored the quality of pictures high and excellent. There was correlation between variables in sentence and word structure (p<0.05 in test-retest, except complex sentences (p=0.137. The agreement rate was 97.1 percent in inter-rater reliability assessment of transcription. The results of inter-rater reliability of language analysis showed that correlation coefficients were significant.Conclusion: The results confirmed that the tool was valid for eliciting language sample. The consistency of language performance in repeated measurement varied from mild to high in language sample analysis approach.

  13. Reliability engineering

    International Nuclear Information System (INIS)

    Lee, Chi Woo; Kim, Sun Jin; Lee, Seung Woo; Jeong, Sang Yeong

    1993-08-01

    This book start what is reliability? such as origin of reliability problems, definition of reliability and reliability and use of reliability. It also deals with probability and calculation of reliability, reliability function and failure rate, probability distribution of reliability, assumption of MTBF, process of probability distribution, down time, maintainability and availability, break down maintenance and preventive maintenance design of reliability, design of reliability for prediction and statistics, reliability test, reliability data and design and management of reliability.

  14. A Malay version of the Child Oral Impacts on Daily Performances (Child-OIDP index: assessing validity and reliability

    Directory of Open Access Journals (Sweden)

    Yusof Zamros YM

    2012-06-01

    Full Text Available Abstract Background The study aimed to develop and test a Malay version of the Child-OIDP index, evaluate its psychometric properties and report on the prevalence of oral impacts on eight daily performances in a sample of 11–12 year old Malaysian schoolchildren. Methods The Child-OIDP index was translated from English into Malay. The Malay version was tested for reliability and validity on a non-random sample of 132, 11–12 year old schoolchildren from two urban schools in Kuala Lumpur. Psychometric analysis of the Malay Child-OIDP involved face, content, criterion and construct validity tests as well as internal and test-retest reliability. Non-parametric statistical methods were used to assess relationships between Child-OIDP scores and other subjective outcome measures. Results The standardised Cronbach’s alpha was 0.80 and the weighted Kappa was 0.84 (intraclass correlation = 0.79. The index showed significant associations with different subjective measures viz. perceived satisfaction with mouth, perceived needs for dental treatment, perceived oral health status and toothache experience in the previous 3 months (p  Conclusion This study indicated that the Malay Child-OIDP index is a valid and reliable instrument to measure the oral impacts of daily performances in 11–12 year old urban schoolchildren in Malaysia.

  15. Equipment considerations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Trace or ultratrace analyses require that the HPLC equipment used, including the detector, be optimal for such determinations. HPLC detectors are discussed at length in Chapter 4; discussion here is limited to the rest of the equipment. In general, commercial equipment is adequate for trace analysis; however, as the authors approach ultratrace analysis, it becomes very important to examine the equipment thoroughly and optimize it, where possible. For this reason they will review the equipment commonly used in HPLC and discuss the optimization steps. Detectability in HPLC is influenced by two factors (1): (a) baseline noise or other interferences that lead to errors in assigning the baseline absorbance; (b) peak width. 87 refs

  16. The effect of water quality on reliability of boiler plants performance

    Directory of Open Access Journals (Sweden)

    Gajić Anto S.

    2010-01-01

    Full Text Available This paper presents sources and types of corrosion processes of boiler tube system of the Thermal Power Plant "Ugljevik". The main goal in the electric power production is to achieve lower prices, which can only be done by providing low maintenance costs. While it is not possible to completely stop corrosion, it could be slowed down and it's effects could be reduced. In order to reduce corrosion to a minimum on thermal power plants' vital equipment, particularly boilers, it is necessary to determine in each particular case the acting mechanism of corrosion and agents that cause it. Damages and failures on thermal power plants are largely caused by the development of various types of corrosion processes. Special attention is given to the preparation of water, considering its importance to the occurrence of corrosion. The following types of corrosion were detected on the screen tube boiler by visual examination on the side of water and steam: erosive, pitting and impact corrosion. The inner surface of screen pipes, from which the scale layer was removed, indicates that the erosive corrosion with the thinning of pipe walls occurs. Perforation of the welded screen pipes shows that stress corrosion occurred on the screen pipe with formation of cracks and that pipe exploded. Pits on the inner surface of the screen pipes, visible after the removal of scale and corrosion products, are proof that pitting corrosion occurred. The causes of corrosion were discovered and proposed measures for their elimination were given.

  17. Follow-up of the evolution of the characteristics and performance of the equipments tested during a KALI campaign

    International Nuclear Information System (INIS)

    Rouaud, J.

    1985-01-01

    One of the four parts of the K1 qualification of the 1E equipments concerns the design basis accidents. The KALI loops allows to create the thermodynamic conditions of these accidents. This paper presents the PROCESS II which concerns the installation of the equipment in conditions representative of those met in nuclear power plants, the control assurance before, during and after the thermodynamic test. A list of qualification tests carried out on the KALI loop is finally given [fr

  18. Use of performance shaping factors and quantified expert judgment in the evaluation of human reliability: an initial appraisal

    International Nuclear Information System (INIS)

    Embrey, D.E.

    1983-05-01

    The first part of the report considers the nature of human reliability assessment, and the techniques currently employed. It is concluded that most approaches are limited by the availability of data. Approaches to the subjective assessment of error are surveyed. A particular technique which has been developed, the Success Likelihood Index Methodology (SLIM), is described in detail, together with the practical steps for its implementation. The results from a trial application of a questionnaire designed to elicit judges' perceptions of the relative importance of performance shaping factors in determining human reliability are analyzed. A revised form of the questionnaire is presented for future use. A pilot experiment to investigate the relationship between subjectively derived indices of success for six tasks and their objective probability of success is described. The results indicate that the SLIM has potential value as a predictive technique. Some requirements for a program of research to produce a generally applicable methodology are set out

  19. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD

    Directory of Open Access Journals (Sweden)

    Formiga MF

    2018-05-01

    Full Text Available Magno F Formiga,1,2 Kathryn E Roach,1 Isabel Vital,3 Gisel Urdaneta,3 Kira Balestrini,3 Rafael A Calderon-Candelario,3,4 Michael A Campos,3,4,* Lawrence P Cahalin1,* 1Department of Physical Therapy, University of Miami Miller School of Medicine, Coral Gables, FL, USA; 2CAPES Foundation, Ministry of Education of Brazil, Brasilia, Brazil; 3Pulmonary Section, Miami Veterans Administration Medical Center, Miami, FL, USA; 4Division of Pulmonary, Allergy, Critical Care and Sleep Medicine, University of Miami Miller School of Medicine, Miami, FL, USA *These authors contributed equally to this work Purpose: The Test of Incremental Respiratory Endurance (TIRE provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP over time. The integration of MIP over inspiratory duration (ID provides the sustained maximal inspiratory pressure (SMIP. Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Patients and methods: Test–retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. Results: All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test–retest reliability with a nearly perfect intraclass correlation coefficient (ICC of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP

  20. Investing American Recovery and Reinvestment Act Funds to Advance Capability, Reliability, and Performance in NASA Wind Tunnels

    Science.gov (United States)

    Sydnor, Goerge H.

    2010-01-01

    The National Aeronautics and Space Administration's (NASA) Aeronautics Test Program (ATP) is implementing five significant ground-based test facility projects across the nation with funding provided by the American Recovery and Reinvestment Act (ARRA). The projects were selected as the best candidates within the constraints of the ARRA and the strategic plan of ATP. They are a combination of much-needed large scale maintenance, reliability, and system upgrades plus creating new test beds for upcoming research programs. The projects are: 1.) Re-activation of a large compressor to provide a second source for compressed air and vacuum to the Unitary Plan Wind Tunnel at the Ames Research Center (ARC) 2.) Addition of high-altitude ice crystal generation at the Glenn Research Center Propulsion Systems Laboratory Test Cell 3, 3.) New refrigeration system and tunnel heat exchanger for the Icing Research Tunnel at the Glenn Research Center, 4.) Technical viability improvements for the National Transonic Facility at the Langley Research Center, and 5.) Modifications to conduct Environmentally Responsible Aviation and Rotorcraft research at the 14 x 22 Subsonic Tunnel at Langley Research Center. The selection rationale, problem statement, and technical solution summary for each project is given here. The benefits and challenges of the ARRA funded projects are discussed. Indirectly, this opportunity provides the advantages of developing experience in NASA's workforce in large projects and maintaining corporate knowledge in that very unique capability. It is envisioned that improved facilities will attract a larger user base and capabilities that are needed for current and future research efforts will offer revenue growth and future operations stability. Several of the chosen projects will maximize wind tunnel reliability and maintainability by using newer, proven technologies in place of older and obsolete equipment and processes. The projects will meet NASA's goal of

  1. The reliability of in-training assessment when performance improvement is taken into account

    NARCIS (Netherlands)

    van Lohuizen, M.T.; Kuks, J.B.; van Hell, E.A.; Raat, A.N.; Stewart, R.E.; Cohen-Schotanus, J.

    2010-01-01

    During in-training assessment students are frequently assessed over a longer period of time and therefore it can be expected that their performance will improve. We studied whether there really is a measurable performance improvement when students are assessed over an extended period of time and how

  2. Validity and reliability of global operative assessment of laparoscopic skills (GOALS) in novice trainees performing a laparoscopic cholecystectomy.

    Science.gov (United States)

    Kramp, Kelvin H; van Det, Marc J; Hoff, Christiaan; Lamme, Bas; Veeger, Nic J G M; Pierie, Jean-Pierre E N

    2015-01-01

    Global Operative Assessment of Laparoscopic Skills (GOALS) assessment has been designed to evaluate skills in laparoscopic surgery. A longitudinal blinded study of randomized video fragments was conducted to estimate the validity and reliability of GOALS in novice trainees. In total, 10 trainees each performed 6 consecutive laparoscopic cholecystectomies. Sixty procedures were recorded on video. Video fragments of (1) opening of the peritoneum; (2) dissection of Calot's triangle and achievement of critical view of safety; and (3) dissection of the gallbladder from the liver bed were blinded, randomized, and rated by 2 consultant surgeons using GOALS. Also, a grade was given for overall competence. The correlation of GOALS with live observation Objective Structured Assessment of Technical Skills (OSATS) scores was calculated. Construct validity was estimated using the Friedman 2-way analysis of variance by ranks and the Wilcoxon signed-rank test. The interrater reliability was calculated using the absolute and consistency agreement 2-way random-effects model intraclass correlation coefficient. A high correlation was found between mean GOALS score (r = 0.879, p = 0.021) and mean OSATS score. The GOALS score increased significantly across the 6 procedures (p = 0.002). The trainees performed significantly better on their sixth when compared with their first cholecystectomy (p = 0.004). The consistency agreement interrater reliability was 0.37 for the mean GOALS score (p = 0.002) and 0.55 for overall competence (p < 0.001) of the 3 video fragments. The validity observed in this randomized blinded longitudinal study supports the existing evidence that GOALS is a valid tool for assessment of novice trainees. A relatively low reliability was found in this study. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  3. U.S. Army Physical Demands Study: Reliability of Simulations of Physically Demanding Tasks Performed by Combat Arms Soldiers.

    Science.gov (United States)

    Foulis, Stephen A; Redmond, Jan E; Frykman, Peter N; Warr, Bradley J; Zambraski, Edward J; Sharp, Marilyn A

    2017-12-01

    Foulis, SA, Redmond, JE, Frykman, PN, Warr, BJ, Zambraski, EJ, and Sharp, MA. U.S. Army physical demands study: reliability of simulations of physically demanding tasks performed by combat arms soldiers. J Strength Cond Res 31(12): 3245-3252, 2017-Recently, the U.S. Army has mandated that soldiers must successfully complete the physically demanding tasks of their job to graduate from their Initial Military Training. Evaluating individual soldiers in the field is difficult; however, simulations of these tasks may aid in the assessment of soldiers' abilities. The purpose of this study was to determine the reliability of simulated physical soldiering tasks relevant to combat arms soldiers. Three cohorts of ∼50 soldiers repeated a subset of 8 simulated tasks 4 times over 2 weeks. Simulations included: sandbag carry, casualty drag, and casualty evacuation from a vehicle turret, move under direct fire, stow ammunition on a tank, load the main gun of a tank, transferring ammunition with a field artillery supply vehicle, and a 4-mile foot march. Reliability was assessed using intraclass correlation coefficients (ICCs), standard errors of measurement (SEMs), and 95% limits of agreement. Performance of the casualty drag and foot march did not improve across trials (p > 0.05), whereas improvements, suggestive of learning effects, were observed on the remaining 6 tasks (p ≤ 0.05). The ICCs ranged from 0.76 to 0.96, and the SEMs ranged from 3 to 16% of the mean. These 8 simulated tasks show high reliability. Given proper practice, they are suitable for evaluating the ability of Combat Arms Soldiers to complete the physical requirements of their jobs.

  4. Learning process for performing and analyzing 3D/4D transperineal ultrasound imaging and interobserver reliability study.

    Science.gov (United States)

    Siafarikas, F; Staer-Jensen, J; Braekken, I H; Bø, K; Engh, M Ellström

    2013-03-01

    To evaluate the learning process for acquiring three- and four-dimensional (3D/4D) transperineal ultrasound volumes of the levator hiatus (LH) dimensions at rest, during pelvic floor muscle (PFM) contraction and on Valsalva maneuver, and for analyzing the ultrasound volumes, as well as to perform an interobserver reliability study between two independent ultrasound examiners. This was a prospective study including 22 women. We monitored the learning process of an inexperienced examiner (IE) performing 3D/4D transperineal ultrasonography and analyzing the volumes. The examination included acquiring volumes during three PFM contractions and three Valsalva maneuvers. LH dimensions were determined in the axial plane. The learning process was documented by estimating agreement between the IE and an experienced examiner (E) using the intraclass correlation coefficient. Agreement was calculated in blocks of 10 ultrasound examinations and analyzed volumes. After the learning process was complete the interobserver reliability for the technique was calculated between these two independent examiners. For offline analysis of the first 10 ultrasound volumes obtained by E, good to very good agreement between E and IE was achieved for all LH measurements except for the left and right levator-urethra gap and pubic arc. For the next 10 analyzed volumes, agreement improved for all LH measurements. Volumes that had been obtained by IE and E were then re-evaluated by IE, and good to very good agreement was found for all LH measurements indicating consistency in volume acquisition. The interobserver reliability study showed excellent ICC values (ICC, 0.81-0.97) for all LH measurements except the pubic arc (ICC = 0.67). 3D/4D transperineal ultrasound is a reliable technique that can be learned in a short period of time. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  5. Proposed limiting values for performance criteria in acceptance testing of diagnostic X-ray equipment in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Baeuml, A.

    1989-01-01

    In the Federal Republic of Germany a new X-ray ordinance came into force in 1988 containing a specific paragraph on quality assurance for all medical X-ray units stipulating acceptance tests, regular checks and supervision by medical bodies and the competent authorities. Acceptance testing is to be performed by engineers from equipment suppliers of manufacturers in new and existing installations. It is expected that the service engineers will adjust the equipment in such a way as to obtain optimal performance before measurements are made, the results of which are to be stated in a certificate describing quality status of the equipment. A working group has developed guidelines for these acceptance tests. Items to be measured are reported and proposed limiting values and their tolerances are discussed. (author)

  6. Proposed limiting values for performance criteria in acceptance testing of diagnostic X-ray equipment in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Baeuml, A.

    1989-01-01

    In the Federal Republic of Germany a new X-ray ordinance came into force in 1988 containing a specific paragraph on quality assurance for all medical X-ray units stipulating acceptance tests, regular checks and supervision by medical bodies and the competent authorities. Acceptance testing is to be performed by engineers from the equipment suppliers or manufacturers in new and also existing installations. It is expected that the service engineers will adjust the equipment in such a way as to obtain optimal performance before measurements are made, the results of which are to be stated in a certificate describing the quality status of the equipment. A working group has developed guidelines for these acceptance tests. The items to be measured are reported and the proposed limiting values and their tolerances are discussed. (author)

  7. On the reliability of steam generator performance at nuclear power plants with WWER type reactors

    International Nuclear Information System (INIS)

    Styrikovich, M.A.; Margulova, T.Kh.

    1974-01-01

    The problem of ensuring reliable operation of steam generators in a nuclear power plant with a water-cooled, water-moderated reactor (WWER) was studied. At a nuclear power plant with a vertical steam generator (specifically, a Westinghouse product) the steam generator tubes were found to have been penetrated. Shutdown was due to corrosion disintegration of the austenitic stainless steel, type 18/8, used as pipe material for the heater surface. The corrosion was the result of the action of chlorine ions concentrated in the moisture contained in the iron oxide films deposited in low parts of the tube bundle, directly at the tube plate. Blowing through did not ensure complete removal of the film, and in some cases the construction features of the steam generator made removal of the film practically impossible. Replacement of type 18/8 stainless steel by other construction material, e.g., Inconel, did not give good results. To ensure reliable operation of vertical steam generators in domestic practice, the generators are designed without a low tube plate (a variant diagram of the vertical steam generator of such construction for the water-cooled, water-moderated reactor 1000 is presented). When low tube plates are used the film deposition is intolerable. For organization of a non-film regime a complex treatment of the feed water is used, in which the amount of complexion is calculated from the stoichmetric ratios with the composition of the feed water. It is noted that, if 100% condensate purification is used with complexon processing of the feed water to the generator, we can calculate the surface of the steam-generator heater without considering the outer placement on the tubes. In this the cost of the steam generator and all the nuclear power plants with WWER type reactors is decreased even with installation of a 100% condensate purification. It is concluded that only simultaneous solution of construction and water-regime problems will ensure relaible operation of

  8. Dataset size and composition impact the reliability of performance benchmarks for peptide-MHC binding predictions

    DEFF Research Database (Denmark)

    Kim, Yohan; Sidney, John; Buus, Søren

    2014-01-01

    Background: It is important to accurately determine the performance of peptide: MHC binding predictions, as this enables users to compare and choose between different prediction methods and provides estimates of the expected error rate. Two common approaches to determine prediction performance...... are cross-validation, in which all available data are iteratively split into training and testing data, and the use of blind sets generated separately from the data used to construct the predictive method. In the present study, we have compared cross-validated prediction performances generated on our last...

  9. Increasing the Performance and Reliability of Power Boiler by Monitoring Thermal and Strength Parameters

    Directory of Open Access Journals (Sweden)

    Sobota Tomasz

    2017-01-01

    Full Text Available The paper presents a method for determination of thermo-flow parameters for steam boilers. This method allows to perform the calculations of the boiler furnace chamber and heat flow rates absorbed by superheater stages. These parameters are important for monitoring the performance of the power unit. Knowledge of these parameters allows determining the degree of the furnace chamber slagging. The calculation can be performed in online mode and use to monitoring of steam boiler. The presented method allows to the operation of steam boiler with high efficiency.

  10. Development of corrosion models to ensure reliable performance of nuclear power plants

    International Nuclear Information System (INIS)

    Kritzky, V.G.; Stjazhkin, P.S.

    1993-01-01

    The safety and reliability of the coolant circuits in nuclear power plants depend much on corrosion and corrosion products transfer processes. Various empirical models have been developed which are applicable to particular sets of operational conditions. In our laboratory a corrosion model has been worked out, which is based on the thermodynamic properties of the compounds, participating in corrosion process and on the assumption, that the corrosion process is controlled by the solubilities of the corrosion products forming the surface oxide layer. The validity of the model has been verified by use of retrospective experimental data, which have been obtained for a series of structural materials such as e.g., carbon and stainless steels, Cu-, Al-, and Zr alloys. With regard for hydriding the model satisfactorily describes stress corrosion cracking process in water-salt environments. This report describes a model based on the thermodynamic properties of the compounds participating in the corrosion process, and on the assumption that the corrosion process is controlled by the solubilities of the corrosion products forming the surface oxide layer

  11. Methodical installations for fast resource testing of reliability of electrotechnical components intended for NPP equipment; Metodicheskie ustanovki dlya uskorennykh roesursnykh ispytanij na nadezhnost ` ehlektrotekhnicheskikh komplektuyushchikh, vkhodyashchikh v sostav oborudovaniya AEhS i yadernykh ustanovok

    Energy Technology Data Exchange (ETDEWEB)

    Shestakov, V S

    1994-12-31

    Installations for testing the electrotechnical equipment, microswitches for mechanical bend tests of cables as well as for high voltage tests of electrotechnical equipment are developed and described.

  12. The Maintenance Personnel Performance Simulation (MAPPS) model: A human reliability analysis tool

    International Nuclear Information System (INIS)

    Knee, H.E.

    1985-01-01

    The Maintenance Personnel Performance Simulation (MAPPS) model is a computerized, stochastic, task-oriented human behavioral model developed to provide estimates of nuclear power plant (NPP) maintenance team performance measures. It is capable of addressing person-machine, person-environment, and person-person relationships, and accounts for interdependencies that exist between the subelements that make up the maintenance task of interest. The primary measures of performance estimated by MAPPS are: 1) the probability of successfully completing the task of interest and 2) the task duration time. MAPPS also estimates a host of other performance indices, including the probability of an undetected error, identification of the most- and least-likely error-prone subelements, and maintenance team stress profiles during task execution

  13. Reliability of six physical performance tests in older people with dementia

    NARCIS (Netherlands)

    Blankevoort, C.G.; Heuvelen, M.J.; Scherder, E.J.A.

    2012-01-01

    Background. Physical performance tests are important for assessing the effect of physical activity interventions in older people with dementia, but their psychometric properties have not been systematically established within this specific population. Objective. The purpose of this study was to

  14. Reliability of Six Physical Performance Tests in Older People With Dementia

    NARCIS (Netherlands)

    Blankevoort, Christiaan G.; van Heuvelen, Marieke J. G.; Scherder, Erik J. A.

    Background. Physical performance tests are important for assessing the effect of physical activity interventions in older people with dementia, but their psychometric properties have not been systematically established within this specific population. Objective. The purpose of this study was to

  15. Performance-based maintenance of gas turbines for reliable control of degraded power systems

    Science.gov (United States)

    Mo, Huadong; Sansavini, Giovanni; Xie, Min

    2018-03-01

    Maintenance actions are necessary for ensuring proper operations of control systems under component degradation. However, current condition-based maintenance (CBM) models based on component health indices are not suitable for degraded control systems. Indeed, failures of control systems are only determined by the controller outputs, and the feedback mechanism compensates the control performance loss caused by the component deterioration. Thus, control systems may still operate normally even if the component health indices exceed failure thresholds. This work investigates the CBM model of control systems and employs the reduced control performance as a direct degradation measure for deciding maintenance activities. The reduced control performance depends on the underlying component degradation modelled as a Wiener process and the feedback mechanism. To this aim, the controller features are quantified by developing a dynamic and stochastic control block diagram-based simulation model, consisting of the degraded components and the control mechanism. At each inspection, the system receives a maintenance action if the control performance deterioration exceeds its preventive-maintenance or failure thresholds. Inspired by realistic cases, the component degradation model considers random start time and unit-to-unit variability. The cost analysis of maintenance model is conducted via Monte Carlo simulation. Optimal maintenance strategies are investigated to minimize the expected maintenance costs, which is a direct consequence of the control performance. The proposed framework is able to design preventive maintenance actions on a gas power plant, to ensuring required load frequency control performance against a sudden load increase. The optimization results identify the trade-off between system downtime and maintenance costs as a function of preventive maintenance thresholds and inspection frequency. Finally, the control performance-based maintenance model can reduce

  16. Maintenance Personnel Performance Simulation (MAPPS) model: a human reliability analysis tool

    International Nuclear Information System (INIS)

    Knee, H.E.

    1985-01-01

    The Maintenance Personnel Performance Simulation (MAPPS) model is a computerized, stochastic, task-oriented human behavioral model developed to provide estimates of nuclear power plant (NPP) maintenance team performance measures. It is capable of addressing person-machine, person-environment, and person-person relationships, and accounts for interdependencies that exist between the subelements that make up the maintenance task of interest. The primary measures of performance estimated by MAPPS are: (1) the probability of successfully completing the task of interest; and (2) the task duration time. MAPPS also estimates a host of other performance indices, including the probability of an undetected error, identification of the most- and least-likely error-prone subelements, and maintenance team stress profiles during task execution. The MAPPS model was subjected to a number of evaluation efforts that focused upon its practicality, acceptability, usefulness, and validity. Methods used for these efforts included a case method approach, consensus estimation, and comparison with observed task performance measures at a NPP. Favorable results, such as close agreement between task duration times for two tasks observed in the field (67.0 and 119.8 minutes, respectively), and estimates by MAPPS (72.0 and 124.0 minutes, respectively) enhance the confidence in the future use of MAPPS. 8 refs., 1 fig

  17. The impact of natural gas/hydrogen mixtures on the performance of end-use equipment : Interchangeability analysis for domestic appliances

    NARCIS (Netherlands)

    de Vries, Harmen; Mokhov, Anatoli V.; Levinsky, Howard B.

    2017-01-01

    The addition of hydrogen derived from renewable power to the natural gas network is being promoted as a viable means of storing excess wind and solar energy. However, the changes in combustion properties of the natural gas upon hydrogen addition can impact the performance of the end-use equipment

  18. The reliability of test results from simple test samples in predicting the fatigue performance of automotive components

    International Nuclear Information System (INIS)

    Fourlaris, G.; Ellwood, R.; Jones, T.B.

    2007-01-01

    The use of high strength steels (HSS) in automotive components is steadily increasing as automotive designers use modern steel grades to improve structural performance, reduce vehicle weight and enhance crash performance. Weight reduction can be achieved by substituting mild steel with a thinner gauge HSS, however, it must be ensured that no deterioration in performance including fatigue capability occurs. In this study, tests have been carried out to determine the effects that gauge and material strength have on the fatigue performance of a fusion welded automotive suspension arm. Current finite element (FE) modelling and fatigue prediction techniques have been evaluated to determine their reliability when used for thin strip steels. Results have shown the fatigue performance of welded components to be independent of the strength of the parent material for the steel grades studied, with material thickness and joining process the key features determining the fatigue performance. The correlation between the fatigue performance of simple welded samples under uniaxial, constant amplitude loading and complex components under biaxial in service road load data, has been shown to be unreliable. This study also indicates that with the application of modern technologies, such as tailor-welded blanks (TWB), significant weight savings can be achieved. This is demonstrated by a 19% weight reduction with no detrimental effect on the fatigue performance

  19. Agreement and Reliability of Functional Performance and Muscle Power in Patients with Advanced Osteoarthritis of the Hip or Knee

    DEFF Research Database (Denmark)

    Villadsen, Allan; Roos, Ewa M; Overgaard, Søren

    2012-01-01

    -time repeated chair stands, and repeated unilateral knee bending). RESULTS: For single-joint and multijoint maximal peak power and functional performance measures, we demonstrated poor (CVws, approximately 25%, single-joint hip extension) and moderate (CVws, approximately 15%, multijoint leg extension press......OBJECTIVE: The purpose of this study was to test the reproducibility and clinical feasibility of three functional performance measures and five single-joint or multijoint muscle power measures. DESIGN: Twenty patients with a mean age of 68.7 ± 7.2 yrs with severe hip or knee osteoarthritis were...... assessed for test-retest reliability and agreement on two occasions 1 wk apart. The outcomes were maximal single-joint muscle power (hip extension/abduction and knee extension/flexion), maximal muscle power during multijoint leg extension press, and functional performance measures (20-m walk, five...

  20. Operational safety performance indicator system - a management tool for the self assessment of safety and reliability of nuclear power plants

    International Nuclear Information System (INIS)

    Anil Kumar; Mandowara, S.L.; Mittal, S.

    2006-01-01

    Operational Safety Performance Indicator system is one of the self assessment tools for station management to monitor safety and reliability of nuclear power plants. It provides information to station management about the performance of various areas of the plants by means of different colours of relevant performance indicators. Such systems have been implemented at many nuclear power plants in the world and have been considered as strength during WANO Peer Review. IAEA had a Coordinated Research Programme (CRP) on this with several countries participating including India. In NPCIL this system has been implemented in KAPS about a year back and found very useful in identifying areas which needs to be given more attention. Based on the KAPS feedback Implementation of this system has been taken up in RAPS-3 and 4 and KGS-l and 2. (author)

  1. Reliability in the performance-based concept of fib Model Code 2010

    NARCIS (Netherlands)

    Bigaj-van Vliet, A.; Vrouwenvelder, T.

    2013-01-01

    The design philosophy of the new fib Model Code for Concrete Structures 2010 represents the state of the art with regard to performance-based approach to the design and assessment of concrete structures. Given the random nature of quantities determining structural behaviour, the assessment of

  2. Determination of validity and reliability of performance assessments tasks developed for selected topics in high school chemistry

    Science.gov (United States)

    Zichittella, Gail Eberhardt

    The primary purpose of this study was to validate performance assessments, which can be used as teaching and assessment instruments in high school science classrooms. This study evaluated the classroom usability of these performance instruments and establishes the interrater reliability of the scoring rubrics when used by classroom teachers. The assessment instruments were designed to represent two levels of scientific inquiry. The high level of inquiry tasks are relatively unstructured in terms of student directions; the low inquiry tasks provided more structure for the student. The tasks cover two content topics studied in chemistry (scientific observation and density). Students from a variety of Western New York school districts who were enrolled in chemistry classes and other science courses were involved in completion of the tasks at the two levels of inquiry. The chemistry students completed the NYS Regents Examination in Chemistry. Their classroom teachers were interviewed and completed a questionnaire to aid in the establishment their epistemological view on the inclusion of inquiry based learning in the science classroom. Data showed that the performance assessment tasks were reliable, valid and helpful for obtaining a more complete picture of the students' scientific understanding. The teacher participants reported no difficulty with the usability of the task in the high school chemistry setting. Collected data gave no evidence of gender bias with reference to the performance tasks or the NYS Regents Chemistry Examination. Additionally, it was shown that the instructors' classroom practices do have an effect upon the students' achievement on the performance tasks and the NYS Regents examination. Data also showed that achievement on the performance tasks was influenced by the number of years of science instruction students had received.

  3. Reliable quantification of BOLD fMRI cerebrovascular reactivity despite poor breath-hold performance.

    Science.gov (United States)

    Bright, Molly G; Murphy, Kevin

    2013-12-01

    Cerebrovascular reactivity (CVR) can be mapped using BOLD fMRI to provide a clinical insight into vascular health that can be used to diagnose cerebrovascular disease. Breath-holds are a readily accessible method for producing the required arterial CO2 increases but their implementation into clinical studies is limited by concerns that patients will demonstrate highly variable performance of breath-hold challenges. This study assesses the repeatability of CVR measurements despite poor task performance, to determine if and how robust results could be achieved with breath-holds in patients. Twelve healthy volunteers were scanned at 3 T. Six functional scans were acquired, each consisting of 6 breath-hold challenges (10, 15, or 20 s duration) interleaved with periods of paced breathing. These scans simulated the varying breath-hold consistency and ability levels that may occur in patient data. Uniform ramps, time-scaled ramps, and end-tidal CO2 data were used as regressors in a general linear model in order to measure CVR at the grey matter, regional, and voxelwise level. The intraclass correlation coefficient (ICC) quantified the repeatability of the CVR measurement for each breath-hold regressor type and scale of interest across the variable task performances. The ramp regressors did not fully account for variability in breath-hold performance and did not achieve acceptable repeatability (ICC0.4). Further analysis of intra-subject CVR variability across the brain (ICCspatial and voxelwise correlation) supported the use of end-tidal CO2 data to extract robust whole-brain CVR maps, despite variability in breath-hold performance. We conclude that the incorporation of end-tidal CO2 monitoring into scanning enables robust, repeatable measurement of CVR that makes breath-hold challenges suitable for routine clinical practice. © 2013.

  4. Reliability analysis of PLC safety equipment

    Energy Technology Data Exchange (ETDEWEB)

    Yu, J.; Kim, J. Y. [Chungnam Nat. Univ., Daejeon (Korea, Republic of)

    2006-06-15

    FMEA analysis for Nuclear Safety Grade PLC, failure rate prediction for nuclear safety grade PLC, sensitivity analysis for components failure rate of nuclear safety grade PLC, unavailability analysis support for nuclear safety system.

  5. Reliability analysis of PLC safety equipment

    International Nuclear Information System (INIS)

    Yu, J.; Kim, J. Y.

    2006-06-01

    FMEA analysis for Nuclear Safety Grade PLC, failure rate prediction for nuclear safety grade PLC, sensitivity analysis for components failure rate of nuclear safety grade PLC, unavailability analysis support for nuclear safety system

  6. Operating performance and reliability of CANDU PHWR fuel channels in Canada

    International Nuclear Information System (INIS)

    Strachan, B.; Brown, D.R.

    1983-03-01

    CANDU nuclear plants use many small-diameter high-pressure fuel channels. Good operating performance from the CANDU fuel channels has made a major contribution to the world-leading operating record of the CANDU nuclear power plants. As of 1982 December 31, there were 7,480 fuel channels installed in 18 CANDU reactors over 500 MW(e) in size. Eight of these reactors have been declared in-service and have accumulated 24,000 fuel channel-years of operation. The only significant operating problems with fuel channels have been the occurrence of leaking cracks in 70 fuel channels and a larger amount of axial creep on the early reactors than was originally provided for in the design. Both of these problems have been corrected on all CANDU reactors built since the Bruce GS 'A' station and the newer reactors should exhibit even better performance

  7. Wind turbine performance: Methods and criteria for reliability of measured power curves

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, D.A. [Advanced Wind Turbines Inc., Seattle, WA (United States)

    1996-12-31

    In order to evaluate the performance of prototype turbines, and to quantify incremental changes in performance through field testing, Advanced Wind Turbines (AWT) has been developing methods and requirements for power curve measurement. In this paper, field test data is used to illustrate several issues and trends which have resulted from this work. Averaging and binning processes, data hours per wind-speed bin, wind turbulence levels, and anemometry methods are all shown to have significant impacts on the resulting power curves. Criteria are given by which the AWT power curves show a high degree of repeatability, and these criteria are compared and contrasted with current published standards for power curve measurement. 6 refs., 5 figs., 5 tabs.

  8. Embedded Sensors and Controls to Improve Component Performance and Reliability -- Loop-scale Testbed Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Melin, Alexander M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kisner, Roger A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-09-01

    Embedded instrumentation and control systems that can operate in extreme environments are challenging to design and operate. Extreme environments limit the options for sensors and actuators and degrade their performance. Because sensors and actuators are necessary for feedback control, these limitations mean that designing embedded instrumentation and control systems for the challenging environments of nuclear reactors requires advanced technical solutions that are not available commercially. This report details the development of testbed that will be used for cross-cutting embedded instrumentation and control research for nuclear power applications. This research is funded by the Department of Energy's Nuclear Energy Enabling Technology program's Advanced Sensors and Instrumentation topic. The design goal of the loop-scale testbed is to build a low temperature pump that utilizes magnetic bearing that will be incorporated into a water loop to test control system performance and self-sensing techniques. Specifically, this testbed will be used to analyze control system performance in response to nonlinear and cross-coupling fluid effects between the shaft axes of motion, rotordynamics and gyroscopic effects, and impeller disturbances. This testbed will also be used to characterize the performance losses when using self-sensing position measurement techniques. Active magnetic bearings are a technology that can reduce failures and maintenance costs in nuclear power plants. They are particularly relevant to liquid salt reactors that operate at high temperatures (700 C). Pumps used in the extreme environment of liquid salt reactors provide many engineering challenges that can be overcome with magnetic bearings and their associated embedded instrumentation and control. This report will give details of the mechanical design and electromagnetic design of the loop-scale embedded instrumentation and control testbed.

  9. Linking Quality Assurance to Performance Improvement to Produce a High Reliability Organization

    International Nuclear Information System (INIS)

    Silvey, Andrea B.; Warrick, Louise H.

    2008-01-01

    Three basic change management models are currently used in healthcare to produce and sustain quality improvement. We have presented the context to determine where any particular organization stands within these paradigms. We also have introduced a change-management tool used to assess, plan, and monitor leadership effort and commitment to quality improvement and culture change activities, tracked as 'momentum for change.' This 'momentum' is measured at eight discrete levels, from recognizing a performance gap to officially implementing changes intended to improve quality

  10. How reliable are geometry-based building indices as thermal performance indicators?

    International Nuclear Information System (INIS)

    Rodrigues, Eugénio; Amaral, Ana Rita; Gaspar, Adélio Rodrigues; Gomes, Álvaro

    2015-01-01

    Highlights: • Geometry-based building indices are tested in different European climate regions. • Building design programs are used to randomly generate sets of simulation models. • Some indices correlate in specific climates and design programs. • Shape-based Relative Compactness presented the best correlation of all indices. • Window-to-Surface Ratio was the window-based index with best correlation. - Abstract: Architects and urban planners have been relying on geometry-based indices to design more energy efficient buildings for years. The advantage of such indices is their ease of use and capability to capture the relation of a few geometric variables with the building’s performance. However, such relation is usually found using only a few simple building models and considering only a few climate regions. This paper presents the analysis of six geometry-based building indices to determine their adequacy in eight different climate regions in Europe. For each location, three residential building design programs were used as building specifications. Two algorithms were employed to randomly generate and assess the thermal performance of three sets of 500 alternative building models. The results show that geometry-based indices only correlate with the buildings’ thermal performance according to specific climate regions and building design programs

  11. RFA-based 589-nm guide star lasers for ESO VLT: a paradigm shift in performance, operational simplicity, reliability, and maintenance

    Science.gov (United States)

    Friedenauer, Axel; Karpov, Vladimir; Wei, Daoping; Hager, Manfred; Ernstberger, Bernhard; Clements, Wallace R. L.; Kaenders, Wilhelm G.

    2012-07-01

    Large telescopes equipped with adaptive optics require 20-25W CW 589-nm sources with emission linewidths of ~5 MHz. These Guide Star (GS) lasers should also be highly reliable and simple to operate and maintain for many years at the top of a mountain facility. Under contract from ESO, industrial partners TOPTICA and MPBC are nearing completion of the development of GS lasers for the ESO VLT, with delivery of the first of four units scheduled for December 2012. We report on the design and performance of the fully-engineered Pre-Production Unit (PPU), including system reliability/availability analysis, the successfully-concluded qualification testing, long-term component and system level tests and long-term maintenance and support planning. The chosen approach is based on ESO's patented narrow-band Raman Fiber Amplifier (EFRA) technology. A master oscillator signal from a linearly-polarized TOPTICA 20-mW, 1178-nm CW diode laser, with stabilized emission frequency and controllable linewidth up to a few MHz, is amplified in an MPBC polarization-maintaining (PM) RFA pumped by a high-power 1120-nm PM fiber laser. With efficient stimulated Brillouin scattering suppression, an unprecedented 40W of narrow-band RFA output has been obtained. This is then mode-matched into a resonant-cavity doubler with a free-spectral-range matching the sodium D2a to D2b separation, allowing simultaneous generation of an additional frequency component (D2b line) to re-pump the sodium atom electronic population. With this technique, the return flux can be increased without having to resort to electro-optical modulators and without the risk of introducing optical wave front distortions. The demonstrated output powers with doubling efficiencies >80% at 589 nm easily exceed the 20W design goal and require less than 700 W of electrical power. In summary, the fiber-based guide star lasers provide excellent beam quality and are modular, turn-key, maintenance-free, reliable, efficient, and ruggedized

  12. Spatial learning and psychomotor performance of C57BL/6 mice: age sensitivity and reliability of individual differences.

    Science.gov (United States)

    de Fiebre, Nancyellen C; Sumien, Nathalie; Forster, Michael J; de Fiebre, Christopher M

    2006-09-01

    Two tests often used in aging research, the elevated path test and the Morris water maze test, were examined for their application to the study of brain aging in a large sample of C57BL/6JNia mice. Specifically, these studies assessed: (1) sensitivity to age and the degree of interrelatedness among different behavioral measures derived from these tests, (2) the effect of age on variation in the measurements, and (3) the reliability of individual differences in performance on the tests. Both tests detected age-related deficits in group performance that occurred independently of each other. However, analysis of data obtained on the Morris water maze test revealed three relatively independent components of cognitive performance. Performance in initial acquisition of spatial learning in the Morris maze was not highly correlated with performance during reversal learning (when mice were required to learn a new spatial location), whereas performance in both of those phases was independent of spatial performance assessed during a single probe trial administered at the end of acquisition training. Moreover, impaired performance during initial acquisition could be detected at an earlier age than impairments in reversal learning. There were modest but significant age-related increases in the variance of both elevated path test scores and in several measures of learning in the Morris maze test. Analysis of test scores of mice across repeated testing sessions confirmed reliability of the measurements obtained for cognitive and psychomotor function. Power calculations confirmed that there are sufficiently large age-related differences in elevated path test performance, relative to within age variability, to render this test useful for studies into the ability of an intervention to prevent or reverse age-related deficits in psychomotor performance. Power calculations indicated a need for larger sample sizes for detection of intervention effects on cognitive components of the

  13. Development of an Expanded, High Reliability Cost and Performance Database for In Situ Remediation Technologies

    Science.gov (United States)

    2016-03-01

    Biomass (cells/mL) 1.0 E+4 1.8 E+7 5.3 E+6 -- 2.7 E+7 DNA (ug/L) 0.04 72 21 -- 108 Dehalococcoides (cells/L) -- -- -- -- ə.0 E+4 Field Measurements...indicates that bioremediation processes could remain on- going for some time at this site. Total biomass concentrations in the most recent sample...of medium to coarse-grained sand and crushed shells . The Pilot Test was performed with three injection wells and three extraction wells over a 20

  14. Reliability calculations

    International Nuclear Information System (INIS)

    Petersen, K.E.

    1986-03-01

    Risk and reliability analysis is increasingly being used in evaluations of plant safety and plant reliability. The analysis can be performed either during the design process or during the operation time, with the purpose to improve the safety or the reliability. Due to plant complexity and safety and availability requirements, sophisticated tools, which are flexible and efficient, are needed. Such tools have been developed in the last 20 years and they have to be continuously refined to meet the growing requirements. Two different areas of application were analysed. In structural reliability probabilistic approaches have been introduced in some cases for the calculation of the reliability of structures or components. A new computer program has been developed based upon numerical integration in several variables. In systems reliability Monte Carlo simulation programs are used especially in analysis of very complex systems. In order to increase the applicability of the programs variance reduction techniques can be applied to speed up the calculation process. Variance reduction techniques have been studied and procedures for implementation of importance sampling are suggested. (author)

  15. Power Electronics Packaging Reliability | Transportation Research | NREL

    Science.gov (United States)

    Packaging Reliability Power Electronics Packaging Reliability A photo of a piece of power electronics laboratory equipment. NREL power electronics packaging reliability research investigates the electronics packaging around a semiconductor switching device determines the electrical, thermal, and

  16. A dissociation between engagement and learning: Enthusiastic instructions fail to reliably improve performance on a memory task.

    Directory of Open Access Journals (Sweden)

    Benjamin A Motz

    Full Text Available Despite widespread assertions that enthusiasm is an important quality of effective teaching, empirical research on the effect of enthusiasm on learning and memory is mixed and largely inconclusive. To help resolve these inconsistencies, we conducted a carefully-controlled laboratory experiment, investigating whether enthusiastic instructions for a memory task would improve recall accuracy. Scripted videos, either enthusiastic or neutral, were used to manipulate the delivery of task instructions. We also manipulated the sequence of learning items, replicating the spacing effect, a known cognitive technique for memory improvement. Although spaced study reliably improved test performance, we found no reliable effect of enthusiasm on memory performance across two experiments. We did, however, find that enthusiastic instructions caused participants to respond to more item prompts, leaving fewer test questions blank, an outcome typically associated with increased task motivation. We find no support for the popular claim that enthusiastic instruction will improve learning, although it may still improve engagement. This dissociation between motivation and learning is discussed, as well as its implications for education and future research on student learning.

  17. A dissociation between engagement and learning: Enthusiastic instructions fail to reliably improve performance on a memory task.

    Science.gov (United States)

    Motz, Benjamin A; de Leeuw, Joshua R; Carvalho, Paulo F; Liang, Kaley L; Goldstone, Robert L

    2017-01-01

    Despite widespread assertions that enthusiasm is an important quality of effective teaching, empirical research on the effect of enthusiasm on learning and memory is mixed and largely inconclusive. To help resolve these inconsistencies, we conducted a carefully-controlled laboratory experiment, investigating whether enthusiastic instructions for a memory task would improve recall accuracy. Scripted videos, either enthusiastic or neutral, were used to manipulate the delivery of task instructions. We also manipulated the sequence of learning items, replicating the spacing effect, a known cognitive technique for memory improvement. Although spaced study reliably improved test performance, we found no reliable effect of enthusiasm on memory performance across two experiments. We did, however, find that enthusiastic instructions caused participants to respond to more item prompts, leaving fewer test questions blank, an outcome typically associated with increased task motivation. We find no support for the popular claim that enthusiastic instruction will improve learning, although it may still improve engagement. This dissociation between motivation and learning is discussed, as well as its implications for education and future research on student learning.

  18. Intra-system reliability of SICS: video-tracking system (Digital.Stadium®) for performance analysis in football.

    Science.gov (United States)

    Beato, Marco; Jamil, Mikael

    2017-05-09

    The correct evaluation of external load parameters is a key factor in professional football. The instrumentations usually utilised to quantify the external load parameters during official matches are Video-Tracking Systems (VTS). VTS is a technology that records two- dimensional position data (x and y) at high sampling rates (over 25 Hz). The aim of this study was to evaluate the intra-system reliability of Digital.Stadium® VTS. 28 professional male football players taking part in the Italian Serie A (age 24 ± 6 years, body mass 79.5 ± 7.8 kg, stature 1.83 ± 0.05 m) during the 2015/16 season were enrolled in this study (Team A and Team B). Video-analysis was done during an official match and data analysis was performed immediately after the game ended and then replicated a week later. This study reported a near perfect relationship between the initial analysis (analysis 1) and the replicated analysis undertaken a week later (analysis 2). R2 coefficients were highly significant for each of the performance parameters, p power of 9.65 ± 1.64 w kg-1 and 9.58 ± 1.61 w kg-1, in analysis 1 and analysis 2, respectively. The findings reported in this study underlined that all data reported by Digital.Stadium® VTS showed high levels of absolute and relative reliability.

  19. Test-retest reliability of maximal leg muscle power and functional performance measures in patients with severe osteoarthritis (OA)

    DEFF Research Database (Denmark)

    Villadsen, Allan; Roos, Ewa M.; Overgaard, Søren

    Abstract : Purpose To evaluate the reliability of single-joint and multi-joint maximal leg muscle power and functional performance measures in patients with severe OA. Background Muscle power, taking both strength and velocity into account, is a more functional measure of lower extremity muscle...... and scheduled for unilateral total hip (n=9) or knee (n=11) replacement. Patients underwent a test battery on two occasions separated by approximately one week (range 7 to 11 days). Muscle power was measured using: 1. A linear encoder, unilateral lower limb isolated single-joint dynamic movement, e.g. knee...... flexion 2. A leg extension press, unilateral multi-joint knee and hip extension Functional performance was measured using: 1. 20 m walk usual pace 2. 20 m walk maximal pace 3. 5 times chair stands 4. Maximal number of knee bends/30sec Pain was measured on a VAS prior to and after conducting the entire...

  20. A Microfabricated Segmented-Involute-Foil Regenerator for Enhancing Reliability and Performance of Stirling Engines

    Science.gov (United States)

    Ibrahim, Mounir; Danila, Daniel; Simon, Terrence; Mantell, Susan; Sun, Liyong; Gadeon, David; Qiu, Songgang; Wood, Gary; Kelly, Kevin; McLean, Jeffrey

    2007-01-01

    An actual-size microfabricated regenerator comprised of a stack of 42 disks, 19 mm diameter and 0.25 mm thick, with layers of microscopic, segmented, involute-shaped flow channels was fabricated and tested. The geometry resembles layers of uniformly-spaced segmented-parallel-plates, except the plates are curved. Each disk was made from electro-plated nickel using the LiGA process. This regenerator had feature sizes close to those required for an actual Stirling engine but the overall regenerator dimensions were sized for the NASA/Sunpower oscillating-flow regenerator test rig. Testing in the oscillating-flow test rig showed the regenerator performed extremely well, significantly better than currently used random-fiber material, producing the highest figures of merit ever recorded for any regenerator tested in that rig over its approximately 20 years of use.

  1. Reliability residual-life prediction method for thermal aging based on performance degradation

    International Nuclear Information System (INIS)

    Ren Shuhong; Xue Fei; Yu Weiwei; Ti Wenxin; Liu Xiaotian

    2013-01-01

    The paper makes the study of the nuclear power plant main pipeline. The residual-life of the main pipeline that failed due to thermal aging has been studied by the use of performance degradation theory and Bayesian updating methods. Firstly, the thermal aging impact property degradation process of the main pipeline austenitic stainless steel has been analyzed by the accelerated thermal aging test data. Then, the thermal aging residual-life prediction model based on the impact property degradation data is built by Bayesian updating methods. Finally, these models are applied in practical situations. It is shown that the proposed methods are feasible and the prediction accuracy meets the needs of the project. Also, it provides a foundation for the scientific management of aging management of the main pipeline. (authors)

  2. Chapter 1: Reliably Measuring the Performance of Emerging Photovoltaic Solar Cells

    Energy Technology Data Exchange (ETDEWEB)

    Rumbles, Garry [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Reese, Matthew O [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Marshall, Ashley [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-08

    Determining the power conversion efficiency of photovoltaic solar cells, especially those from new, emerging areas of technology, is important if advances in performance are to be made. However, although precise measurements are important, it is the accuracy of these types of measurements that can cause issues. Accurate measurements not only promote the development of new technology platforms, but they also enable comparisons with established technologies and allow assessments of advancements within the same field. This chapter provides insights into how measurements can be made with reasonable accuracy using both the components of the measuring system and a good protocol to acquire good data. The chapter discusses how to measure a calibrated lamp spectrum, determine a spectral mismatch factor, identify the correct reference cell and filter, define the illuminated active area, measure J-V curves to avoid any hysteresis effects, take note of sample degradation issues and avoid the temptation to artificially enhance efficiency data.

  3. RETRIEVAL EQUIPMENT DESCRIPTIONS

    International Nuclear Information System (INIS)

    J. Steinhoff

    1997-01-01

    The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) retrieval from the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. There are no quality assurance requirements or QA controls in this document. Retrieval under normal conditions is accomplished with the same fleet of equipment as is used for emplacement. Descriptions of equipment used for retrieval under normal conditions is found in Emplacement Equipment Descriptions, DI: BCAF00000-01717-5705-00002 (a document in progress). Equipment used for retrieval under abnormal conditions is addressed in this document and consists of the following: (1) Inclined Plane Hauler; (2) Bottom Lift Transporter; (3) Load Haul Dump (LHD) Loader; (4) Heavy Duty Forklift for Emplacement Drifts; (5) Covered Shuttle Car; (6) Multipurpose Vehicle; and (7) Scaler

  4. Equipment Obsolescence Management Program

    Energy Technology Data Exchange (ETDEWEB)

    Redmond, J.

    2014-07-01

    Nuclear Power Plant (NPP) Operators are challenged with securing reliable supply channels for safety related equipment due to equipment obsolescence. Many Original Equipment Manufacturers (OEMs) have terminated production of spare parts and product life-cycle support. The average component life cycles are much shorter than the NPP design life, which means that replacement components and parts for the original NPP systems are not available for the complete design life of the NPPs. The lack or scarcity of replacement parts adversely affects plant reliability and ultimately the profitability of the affected NPPs. This problem is further compounded when NPPs pursue license renewal and approval for plant-life extension. A reliable and predictable supply of replacement co components is necessary for NPPs to remain economically competitive and meet regulatory requirements and guidelines. Electrical and I and C components, in particular, have short product life cycles and obsolescence issues must be managed pro actively and not reactively in order to mitigate the risk to the NPP to ensure reliable and economic NPP operation. (Author)

  5. 29 CFR 1926.95 - Criteria for personal protective equipment.

    Science.gov (United States)

    2010-07-01

    ..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Personal Protective and Life... in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or... construction for the work to be performed. (d) Payment for protective equipment. (1) Except as provided by...

  6. Performance of synchrotron x-ray monochromators under heat load: How reliable are the predictions?

    International Nuclear Information System (INIS)

    Freund, A.K.; Hoszowska, J.; Migliore, J.-S.; Mocella, V.; Zhang, L.; Ferrero, C.

    2000-01-01

    With the ongoing development of insertion devices with smaller gaps the heat load generated by modern synchrotron sources increases continuously. To predict the overall performance of experiments on beam lines it is of crucial importance to be able to predict the efficiency of x-ray optics and in particular that of crystal monochromators. We report on a detailed comparison between theory and experiment for a water-cooled silicon crystal exposed to bending magnet radiation of up to 237 W total power and 1.3 W/mm2 power density. The thermal deformation has been calculated by the code ANSYS and its output has been injected into a finite difference code based on the Takagi-Taupin diffraction theory for distorted crystals. Several slit settings, filters and reflection orders were used to vary the geometrical conditions and the x-ray penetration depth in the crystal. In general, good agreement has been observed between the calculated and the observed values for the rocking curve width

  7. How do nurses and teachers perform breast self-examination: are they reliable sources of information?

    Directory of Open Access Journals (Sweden)

    Ozvurmaz Safiye

    2007-06-01

    Full Text Available Abstract Background Breast cancer is the most common cause of cancer-related deaths among women worldwide. The aim of the present study was to determine and compare knowledge, behavior and attitudes among female nurses and teachers concerning breast self-examination (BSE. Methods Two-hundred and eighty nine women working in Aydin, Turkey (125 nurses and 164 teachers were included in the study. The data were collected using a questionnaire designed to measure the knowledge, attitudes and behavior of the groups. Analysis involved percentiles, χ2 tests, t tests and factor analysis. Results The knowledge of nurses about BSE was higher than that of teachers (81.5% versus 45.1%; p 0.05, whereas skills in performing self-examination were higher in nurses (p Conclusion We conclude that nurses and teachers should be supported with information enabling them to accomplish their roles in the community. To improve BSE practice, it is crucial to coordinate continuous and planned education.

  8. Charging performance of automotive batteries-An underestimated factor influencing lifetime and reliable battery operation

    Science.gov (United States)

    Sauer, Dirk Uwe; Karden, Eckhard; Fricke, Birger; Blanke, Holger; Thele, Marc; Bohlen, Oliver; Schiffer, Julia; Gerschler, Jochen Bernhard; Kaiser, Rudi

    Dynamic charge acceptance and charge acceptance under constant voltage charging conditions are for two reasons essential for lead-acid battery operation: energy efficiency in applications with limited charging time (e.g. PV systems or regenerative braking in vehicles) and avoidance of accelerated ageing due to sulphation. Laboratory tests often use charge regimes which are beneficial for the battery life, but which differ significantly from the operating conditions in the field. Lead-acid batteries in applications with limited charging time and partial-state-of-charge operation are rarely fully charged due to their limited charge acceptance. Therefore, they suffer from sulphation and early capacity loss. However, when appropriate charging strategies are applied most of the lost capacity and thus performance for the user may be recovered. The paper presents several aspects of charging regimes and charge acceptance. Theoretical and experimental investigations show that temperature is the most critical parameter. Full charging within short times can be achieved only at elevated temperatures. A strong dependency of the charge acceptance during charging pulses on the pre-treatment of the battery can be observed, which is not yet fully understood. But these effects have a significant impact on the fuel efficiency of micro-hybrid electric vehicles.

  9. Embedded Sensors and Controls to Improve Component Performance and Reliability -- Bench-scale Testbed Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Melin, Alexander M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kisner, Roger A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Drira, Anis [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Reed, Frederick K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-09-01

    Embedded instrumentation and control systems that can operate in extreme environments are challenging due to restrictions on sensors and materials. As a part of the Department of Energy's Nuclear Energy Enabling Technology cross-cutting technology development programs Advanced Sensors and Instrumentation topic, this report details the design of a bench-scale embedded instrumentation and control testbed. The design goal of the bench-scale testbed is to build a re-configurable system that can rapidly deploy and test advanced control algorithms in a hardware in the loop setup. The bench-scale testbed will be designed as a fluid pump analog that uses active magnetic bearings to support the shaft. The testbed represents an application that would improve the efficiency and performance of high temperature (700 C) pumps for liquid salt reactors that operate in an extreme environment and provide many engineering challenges that can be overcome with embedded instrumentation and control. This report will give details of the mechanical design, electromagnetic design, geometry optimization, power electronics design, and initial control system design.

  10. DJFS: Providing Highly Reliable and High‐Performance File System with Small‐Sized

    Directory of Open Access Journals (Sweden)

    Junghoon Kim

    2017-11-01

    Full Text Available File systems and applications try to implement their own update protocols to guarantee data consistency, which is one of the most crucial aspects of computing systems. However, we found that the storage devices are substantially under‐utilized when preserving data consistency because they generate massive storage write traffic with many disk cache flush operations and force‐unit‐access (FUA commands. In this paper, we present DJFS (Delta‐Journaling File System that provides both a high level of performance and data consistency for different applications. We made three technical contributions to achieve our goal. First, to remove all storage accesses with disk cache flush operations and FUA commands, DJFS uses small‐sized NVRAM for a file system journal. Second, to reduce the access latency and space requirements of NVRAM, DJFS attempts to journal compress the differences in the modified blocks. Finally, to relieve explicit checkpointing overhead, DJFS aggressively reflects the checkpoint transactions to file system area in the unit of the specified region. Our evaluation on TPC‐C SQLite benchmark shows that, using our novel optimization schemes, DJFS outperforms Ext4 by up to 64.2 times with only 128 MB of NVRAM.

  11. The cognitive environment simulation as a tool for modeling human performance and reliability

    International Nuclear Information System (INIS)

    Woods, D.D.; Pople, H. Jr.

    1989-01-01

    Various studies have shown that intention errors, or cognitive error, are a major contributor to the risk of disaster. Intention formation refers to the cognitive processes by which an agent decides on what actions are appropriate to carry out (information gathering, situation assessment, diagnosis, response selection). Understanding, measuring, predicting and correcting cognitive errors depends on the answers to the question - what are difficult problems? The answer to this question defines what are risky situations from the point of view of what incidents will the human-technical system manage safely and what incidents will the human-technical system manage poorly and evolve towards negative outcomes. The authors have made progress in the development of such measuring devices through an NRC sponsored research program on cognitive modeling of operator performance. The approach is based on the demand-resource match view of human error. In this approach the difficulty of a problem depends on both the nature of the problem itself and on the resources (e.g., knowledge, plans) available to solve the problem. One can test the difficulty posed by a domain incident, given some set of resources by running the incident through a cognitive simulation that carries out the cognitive activities of a limited resource problem solver in a dynamic, uncertain, risky and highly doctrinal (pre-planned routines and procedures) world. The cognitive simulation that they have developed to do this in NPP accidents is called the Cognitive Environment Simulation (CES). They will illustrate the power of this approach by comparing the behavior of operators in variants on a simulated accident to the behavior of CES in the same accidents

  12. A Reliable Bistable Board Implementation through I/O Redundancy

    International Nuclear Information System (INIS)

    Kim, Min Gyu; Chung, Tae Hyok; Lee, Youn Sang; Kim, Tae Hee; Song, Seung Hwan

    2010-01-01

    Nuclear power plant safety systems and related equipment used in the design, including an accident in all driving conditions that must be proven In addition, the safety-related equipment that is derived according to the digitization of the safety equipment is the most important factors. Therefore, it is necessary to prove that the device was satisfied the requirements for a given performance for safety-related digital equipment for the life of the installation. These proven is done through the process, design verification of the equipment, production management, such as installation and maintenance. Among other things, it is most important to implement of the performance and reliability features the safety-related equipment in the design phase. In this paper, Bistable Board implemented to generate a ESF sign-on signal throughout the signal processing of input signal from sensors. Also, for the reliable signal input and output, I/O Module that implements the redundancy increases the reliability of the Bistable Board , to verify the performance of safety-related equipment

  13. Procedure for field axes measurement, beam indication adjustment, and figure of convergence determination within performance tests for radiation therapy equipment

    Energy Technology Data Exchange (ETDEWEB)

    Quast, U; Krause, K; Rassow, J [Essen Univ. (Gesamthochschule) (Germany, F.R.). Abt. fuer Klinische Strahlenphysik

    1976-09-01

    A routine measuring procedure for the verification of radiation field axes and figure of convergence within a spatial resolution of +- 0.5 mm is described. Measurements are done in two parallel planes in a certain distance before and behind the presumed isocentre. The used test arrangement permits rapid check and controlled adjustment of the alignment of beam or isocentre indicating devices for all isocentric radiation therapy equipment.

  14. Improved Mechanical Performance Fracture Properties and Reliability of Radical-Cured Thermosets

    Energy Technology Data Exchange (ETDEWEB)

    Redline, Erica Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bolintineanu, Dan S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lane, J. Matthew [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stevens, Mark J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Alam, Todd M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Celina, Mathias C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    The aim of this study was to alter polymerization chemistry to improve network homogeneity in free-radical crosslinked systems. It was hypothesized that a reduction in heterogeneity of the network would lead to improved mechanical performance. Experiments and simulations were carried out to investigate the connection between polymerization chemistry, network structure and mechanical properties. Experiments were conducted on two different monomer systems - the first is a single monomer system, urethane dimethacrylate (UDMA), and the second is a two-monomer system consisting of bisphenol A glycidyl dimethacrylate (BisGMA) and triethylene glycol dimethacrylate (TEGDMA) in a ratio of 70/30 BisGMA/TEGDMA by weight. The methacrylate systems were crosslinked using traditional radical polymeriza- tion (TRP) with azobisisobutyronitrile (AIBN) or benzoyl peroxide (BPO) as an initiator; TRP systems were used as the control. The monomers were also cross-linked using activator regenerated by electron transfer atom transfer radical polymerization (ARGET ATRP) as a type of controlled radical polymerization (CRP). FTIR and DSC were used to monitor reac- tion kinetics of the systems. The networks were analyzed using NMR, DSC, X-ray diffraction (XRD), atomic force microscopy (AFM), and small angle X-ray scattering (SAXS). These techniques were employed in an attempt to quantify differences between the traditional and controlled radical polymerizations. While a quantitative methodology for characterizing net- work morphology was not established, SAXS and AFM have shown some promising initial results. Additionally, differences in mechanical behavior were observed between traditional and controlled radical polymerized thermosets in the BisGMA/TEGDMA system but not in the UDMA materials; this finding may be the result of network ductility variations between the two materials. Coarse-grained molecular dynamics simulations employing a novel model of the CRP reaction were carried out for

  15. The validity and reliability of the my jump 2 app for measuring the reactive strength index and drop jump performance.

    Science.gov (United States)

    Haynes, Tom; Bishop, Chris; Antrobus, Mark; Brazier, Jon

    2018-03-27

    This is the first study to independently assess the concurrent validity and reliability of the My Jump 2 app for measuring drop jump performance. It is also the first to evaluate the app's ability to measure the reactive strength index (RSI). Fourteen male sport science students (age: 29.5 ± 9.9 years) performed three drop jumps from 20 cm and 40 cm (totalling 84 jumps), assessed via a force platform and the My Jump 2 app. Reported metrics included reactive strength index, jump height, ground contact time, and mean power. Measurements from both devices were compared using the intraclass correlation coefficient (ICC), Pearson product moment correlation coefficient (r), Cronbach's alpha (α), coefficient of variation (CV) and BlandAltman plots. Near perfect agreement was seen between devices at 20 cm for RSI (ICC = 0.95) and contact time (ICC = 0.99) and at 40 cm for RSI (ICC = 0.98), jump height (ICC = 0.96) and contact time (ICC = 0.92); with very strong agreement seen at 20 cm for jump height (ICC = 0.80). In comparison with the force plate the app showed good validity for RSI (20 cm: r = 0.94; 40 cm; r = 0.97), jump height (20 cm: r = 0.80; 40 cm; r = 0.96) and contact time (20 cm = 0.96; 40 cm; r = 0.98). The results of the present study show that the My Jump 2 app is a valid and reliable tool for assessing drop jump performance.

  16. LESSONS LEARNED IN TESTING OF SAFEGUARDS EQUIPMENT

    International Nuclear Information System (INIS)

    Pepper, S.; Farnitano, M.; Carelli, J.; Hazeltine, J.; Bailey, D.

    2001-01-01

    The International Atomic Energy Agency's (IAEA) Department of Safeguards uses complex instrumentation for the application of safeguards at nuclear facilities around the world. Often, this equipment is developed through cooperation with member state support programs because the Agency's requirements are unique and are not met by commercially available equipment. Before approving an instrument or system for routine inspection use, the IAEA subjects it to a series of tests designed to evaluate its reliability. In 2000, the IAEA began to observe operational failures in digital surveillance systems. In response to the observed failures, the IAEA worked with the equipment designer and manufacturer to determine the cause of failure. An action plan was developed to correct the performance issues and further test the systems to make sure that additional operational issues would not surface later. This paper addresses the steps taken to address operation issues related to digital image surveillance systems and the lessons learned during this process

  17. Assessing the performance of commercial Agisoft PhotoScan software to deliver reliable data for accurate3D modelling

    Directory of Open Access Journals (Sweden)

    Jebur Ahmed

    2018-01-01

    Full Text Available 3D models delivered from digital photogrammetric techniques have massively increased and developed to meet the requirements of many applications. The reliability of these models is basically dependent on the data processing cycle and the adopted tool solution in addition to data quality. Agisoft PhotoScan is a professional image-based 3D modelling software, which seeks to create orderly, precise n 3D content from fixed images. It works with arbitrary images those qualified in both controlled and uncontrolled conditions. Following the recommendations of many users all around the globe, Agisoft PhotoScan, has become an important source to generate precise 3D data for different applications. How reliable is this data for accurate 3D modelling applications is the current question that needs an answer. Therefore; in this paper, the performance of the Agisoft PhotoScan software was assessed and analyzed to show the potential of the software for accurate 3D modelling applications. To investigate this, a study was carried out in the University of Baghdad / Al-Jaderia campus using data collected from airborne metric camera with 457m flying height. The Agisoft results show potential according to the research objective and the dataset quality following statistical and validation shape analysis.

  18. Mechanical development for reliable reactor components

    International Nuclear Information System (INIS)

    Ross-Ross, P.A.; Metcalfe, R.

    1983-09-01

    The CANDU reactor has achieved worldwide distinction because of its reliable performance. To achieve this, special attention was given to the reliability and maintainability of components in the heavy water circuits. Development programs were initiated early in the history of the CANDU reactor to improve the effectiveness of pump seals, valves, and static seals because of unacceptable performance of the commercial equipment then available. As a result, pump seals with a five year life now appear achievable, and valves and static seals are no longer a significant concern in CANDU reactors. Increasing effort is being given remotely operated tools and fabrication systems for radioactive environments

  19. Erosion of wind turbine blade coatings - Design and analysis of jet-based laboratory equipment for performance evaluation

    DEFF Research Database (Denmark)

    Zhang, Shizhong; Dam-Johansen, Kim; Nørkjær, Sten

    2015-01-01

    of the blades in such equipment. To reduce expensive blade maintenance repairs and to avoid out-of-service periods, energy-absorbing blade coatings are required to protect rotor blades from rain erosion. In this work we describe the design, construction and evaluation of a laboratory setup for fast screening...... experimental blade coatings were investigated using the proposed experimental design. The evaluation of the coatings under conditions where impact frequency and water hammer pressure were "matched" could not be directly correlated with the results obtained with the whirling arm rig. This result may...

  20. Practices of prolongation of the I and C equipment lifetime

    International Nuclear Information System (INIS)

    Samoylov, O.B.; Pronin, V.S.; Savelov, I.D.; Bogomazov, V.A.; Drumov, V.V.; Chudin, A.G.

    2000-01-01

    The lifetime of nuclear power plants (NPP) always exceeds the operational time of Instrumentation and Control (I and C) systems. Ageing of I and C equipment in NPPs have many aspects. Research of these aspects is being performed in OKB Mechanical Engineering. Under condition of fast development of I and C systems and applying more stringent safety requirements, modernization of the equipment irrespective of its operational condition is getting important. However, an equipment of I and C systems operated in Russia was designed and manufactured applying highest requirements for a reliability of their work during its whole operational time. Therefore, in many cases it is not necessary to replace them in spite of expiration of their specified lifetime. During operation this equipment is maintained in a proper operation condition by a special service procedures stipulated by its development. When the equipment lifetime approaches to its end, lifetime extension for the certain period should be considered. (author)