WorldWideScience

Sample records for equipment exchange unit

  1. Corrosion resistance of heat exchange equipment in hydrotreating Orenburg Condensate

    International Nuclear Information System (INIS)

    Teslya, B.M.; Burlov, V.V.; Parputs, I.V.; Parputs, T.P.

    1986-01-01

    The authors study the corrosion resistance of materials of construction and select appropriate materials for the fabrication of heat exchange equipment that will be serviceable under hydrotreating conditions. This paper discusses the Orenburg condensate hydrotreating unit which has been shut down repeatedly for repair because of corrosion damage to components of heat exchangers in the reactor section: tube bundles (08Kh18N10T steel), corrugated compensators (12Kh18N10T steel), and pins of the floating heads (37Kh13N8G8MFB steel). The authors recommend that the tube bundles and the compensators in heat exchangers in the reaction section should be fabricated of 08Kh21N6M2T or 10Kh17N13M2T steel. The pins have been replaced by new pins made of 10Kh17N13 X M2T steel, increasing the service life from 6-12 months to 2 years

  2. Depleted ion exchange resins encapsulation with mobile unit: equipment and experience

    International Nuclear Information System (INIS)

    Cohen, S.; Faisantieu, D.

    1986-01-01

    Since 1981, STMI has been operating mobile units in EDF's PWR nuclear power plants, for spent resins encapsulation with polymer thermosetting matrices. Three mobile units are now in operation: COMET 1 and COMET 2, supplied by STMI, using polymerized styrene with proper additives as encapsulating material, and PRECED 1, on PEC-Engineering design, based on a DOW Chemical solidification process. On march 1986, more than 30 operations have been performed on EDF's PWR plants. More than 5000 liners containing encapsulated depleted ion exchange resins have been produced, while processing about 500 m 3 (i.e. 17.000 ft 3 ) of resins. During this period, those mobile units have shown their reliability and their efficiency. The produced processed waste, which have been accepted by ANDRA at the La Manche Storage Site (SSM) must meet the Fundamental Safety Rules (RFS) edicted by the Central Bureau for Nuclear Facilities Safety (SCSIN) of the French Department of Industry. The operations are carried out with excellent safety and radioprotection safety conditions, and following a very detailed Q.A. program [fr

  3. Methods for tube attachment in a heat exchange equipment

    International Nuclear Information System (INIS)

    Shilin, O.V.; Vasil'ev, V.B.

    1984-01-01

    Two main ways of attaching tubes to tube panels in heat exchange equipment are analyzed: expanding and pulse method (by explosion, for instance). Labour-consumption and cost price for the fastening of brass, perlitic and corrosion-resistant tubes for both of the methods are presented. The extent of fitting out with equipment for tube fixing and ways of testing the joints for attachment are evaluated. Measures for improving the joint quality and introduction of the advanced technology are suggested

  4. Design Modification of Kori Unit 1 for the Equipment Qualification

    International Nuclear Information System (INIS)

    Park, J. W.; Kim, M. Y.; Han, K. T.; Park, J. D.

    2007-01-01

    There has not been a strict regulatory requirements for the Equipment Qualification(EQ) in 1970's when Kori Unit 1 had begun the construction and the commercial operation. The Korean regulatory body requested the EQ on the various safety-related components, as a result of Periodic Safety Review. However, the EQ itself is impossible in some areas, due to the high pressure/temperature and flooding environment conditions from the pipe breaks. Design modification is being considered in the Auxiliary Building, the Intermediate Building, the Component Cooling Water Heat Exchanger Building and the Turbine Building, in order to mitigate the environmental conditions for the EQ

  5. Effectiveness-NTU analyses in a double tube heat exchanger equipped with wavy strip considering various angles

    International Nuclear Information System (INIS)

    Pourahmad, Saman; Pesteei, S.M.

    2016-01-01

    Highlights: • Double tube heat exchanger equipped with wavy strip turbulators was studied. • The effects of wavy strip angles on the effectiveness were investigated. • Variation of the effectiveness with hot and cold water flow rate was presented. • The effectiveness increases with the decrease of wavy strip angle. • The friction factor increases with the decrease of wavy strip angle. - Abstract: In the present study, effectiveness-NTU analyses in a double tube heat exchanger equipped with wavy strip considering various angles were experimentally studied. Moreover, variation of the effectiveness with hot water Reynolds numbers for different cold water flow rates were presented. These turbulators with different angles of 45°, 60°, 90°, 120° and 150° were made of galvanized plates with thickness of 1 mm and were installed in the inner tube of heat exchanger. The experiments were carried out at Reynolds numbers of 3000–13,500 at turbulent flow regime. Throughout the experiments, hot and cold water flowed through the inner pipe and the space between the pipes (annulus), respectively. It was tried to keep the inlet hot and cold water temperatures at constant values. Effectiveness-NTU analyses were made for the conditions with and without wavy strips including their different angles and compared to each other. Results showed the considerable effect of turbulators on effectiveness (ε) and number of heat transfer units (NTU) of double tube heat exchanger. In addition, some empirical correlations expressing the results were also developed based on curve fitting.

  6. Unified electronic unit for miniature radioactivity logging equipment

    International Nuclear Information System (INIS)

    Bragin, A.A.; Goldshtejn, L.M.; Fedorov, R.F.; Shikhman, A.S.

    1981-01-01

    Appropriateness and urgency of the unification of components of radioactivity logging equipment used for the investigation of wells at solid mineral deposits is substantiated. A two-channel electronic unit for miniature equipment for radioactivity logging is described and its basic specifications and performance are given. All functional assemblies of the unit are structurally made in the form of printed circuit boards placed in a pan-shaped chassis 28 mm in diameter. The unit's general design provides for the possibility to attach two probes with detection devices to the unit. The unit is used in the two-channel radioactivity logging instrument ''Kura-2'' and in the two-channel radiometer ''RUR-2''. The outer diameter of these instruments is 48 mm and they ensure the investigation of ore and coal wells with a combination radioactivity methods [ru

  7. The digital ultrasonic test unit for automatic equipment

    International Nuclear Information System (INIS)

    Hiraoka, T.; Matsuyama, H.

    1976-01-01

    The operations and features of the ultrasonic test unit used and the digital data processing techniques employed are described. This unit is used for a few hundred multi-channel automatic ultrasonic test equipment

  8. Restoration to serviceability of Bruce 'A' heat transfer equipment

    International Nuclear Information System (INIS)

    Gammage, D.; Machowski, C.; McGillivray, R.; Durance, D.; Kazimer, D.; Werner, K.

    2009-01-01

    Bruce Units 1 to 4 were shut down during the 1990s by the former Ontario Hydro, due in part to a long list of system and equipment deficiencies and concerns, including steam generator tube degradation as a consequence of the then-existing steam generator secondary side water chemistry conditions. Upon its creation in 2001, and following a program of condition assessment, Bruce Power was able to determine that Units 3 and 4 could return to service; but that Units 1 and 2 would require refurbishment. That Refurbishment Program, which is currently well advanced, included the re-assessment of the condition of equipment throughout the plant including the heat transfer equipment; and determination item-by-item as to what inspection, cleaning, repair, or even replacement would be required to put the equipment into a condition where it could be expected to operate reliably for the additional 30 years expected from the plant. Clearly the objective is to suitably restore the equipment to serviceability without doing more refurbishment work than is warranted - without replacing equipment except where absolutely necessary. The first task in such a program is determination of its scope - i.e. a listing of all heat exchangers. That list included everything from the steam generators (which required replacement, now completed), to much smaller heat exchangers in the heavy water upgrader systems (which were found to be in very good overall condition). There is also a very large number of other so-called 'balance-of-plant' heat exchangers; these include the maintenance coolers, moderator heat exchangers, shutdown coolers and a whole raft of smaller coolers - many of which are cooled directly by lake water with its potential for bio-fouling and 'BIC' (Biologically Induced Corrosion). This paper focuses primarily on the engineering assessment, inspection, repair and general refurbishment of the balance-of-plant heat exchangers. As will be discussed in the paper, the assessment of the

  9. Rehabilitation of heat exchange equipment a key to power plant life extension and performance improvement

    Energy Technology Data Exchange (ETDEWEB)

    Taveau, F.; Huiban, A.M. [Alstom Power Heat Exchange, 78 - Velizy Villacoublay (France)

    2001-07-01

    With the current evolutions of the energy market and the life extension of the power plants, all the equipment initially supplied need one day or another partial or total rehabilitation. For heat exchange equipment, this includes the condensers, feed water heaters and various heat exchangers. Modernization is in particular necessary when in-service monitoring and periodic inspections show significant deteriorations of the tubes and cooling water leakages leading to forced outages or when tube and tube plate materials are no longer suited to cooling water characteristics or to updated specifications of the secondary system. Feedwater heaters and heat exchangers damaged by erosion/corrosion, vibrations, etc. can be re-designed, manufactured and replaced easily. The operation is more complex on condensers and requires technical surveys, study of alternative solutions and has a more direct impact on the global output of the power plant. That is why our conference will focus on the condenser refurbishment. (author)

  10. Rehabilitation of heat exchange equipment a key to power plant life extension and performance improvement

    International Nuclear Information System (INIS)

    Taveau, F.; Huiban, A.M.

    2001-01-01

    With the current evolutions of the energy market and the life extension of the power plants, all the equipment initially supplied need one day or another partial or total rehabilitation. For heat exchange equipment, this includes the condensers, feed water heaters and various heat exchangers. Modernization is in particular necessary when in-service monitoring and periodic inspections show significant deteriorations of the tubes and cooling water leakages leading to forced outages or when tube and tube plate materials are no longer suited to cooling water characteristics or to updated specifications of the secondary system. Feedwater heaters and heat exchangers damaged by erosion/corrosion, vibrations, etc. can be re-designed, manufactured and replaced easily. The operation is more complex on condensers and requires technical surveys, study of alternative solutions and has a more direct impact on the global output of the power plant. That is why our conference will focus on the condenser refurbishment. (author)

  11. Information technology equipment cooling method

    Science.gov (United States)

    Schultz, Mark D.

    2015-10-20

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools air utilized by the rack of information technology equipment to cool the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat generated by the rack of information technology equipment.

  12. Information technology equipment cooling system

    Science.gov (United States)

    Schultz, Mark D.

    2014-06-10

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools warm air generated by the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat from the rack of information technology equipment.

  13. Sustainability assessment of heat exchanger units for spray dryers

    International Nuclear Information System (INIS)

    Caglayan, Hasan; Caliskan, Hakan

    2017-01-01

    In this study, the sustainability assessment is performed to the system known as heat exchanger unit with spray dryer. The five-different dead state temperatures (0-5-10-15-20 °C) are considered. It is found that the heat exchanger has the highest energy efficiency (63.32%), while the overall system has the lowest one (5.56%). So, the combination of the spray dryer with the heat exchanger is more effective. On the other hand, the overall exergy efficiency of the system is lower than the heat exchanger and spray dryer for all of the dead state (environmental) temperatures. The exergy efficiency of the heat exchanger is inversely proportional to the dead state temperature, and the maximum rate is found as 49.65% at 0 °C. Furthermore, the exergy efficiencies of the spray dryer and overall system are directly proportional to the dead state temperatures, and the corresponding maximum rates are found to be 26.41% and 24.32% at 20 °C, respectively. Also, the exergy destruction is directly proportional to the dead state temperatures. The minimum and maximum exergy destruction rates are found at the dead state temperatures of 0 °C and 20 °C, respectively. Furthermore, the most sustainable system is found as the heat exchanger unit. - Highlights: • Thermodynamic analyses of industrial heat exchangers and spray dryers. • Sustainability of heat exchangers for spray dryers. • Dead state temperature effects on exergy efficiencies of heat exchangers and spray dryers.

  14. Application of ion-exchange unit in uranium extraction process in China (to be continued)

    International Nuclear Information System (INIS)

    Gong Chuanwen

    2004-01-01

    The application conditions of five different ion exchange units in uranium milling plant and wastewater treatment plant of uranium mine in China are introduced, including working parameters, existing problems and improvements. The advantages and disadvantages of these units are reviewed briefly. The procedure points to be followed in selecting ion exchange unit are recommended in the engineering design. The primary views are presented upon the application prospects of some ion exchange units in uranium extraction process in China

  15. Efficient fully controlled up-to-date equipment for catalytic treatment of waste gases

    International Nuclear Information System (INIS)

    Dvorak, Radek; Stulir, Roman; Cagas, Pavel

    2007-01-01

    This paper describes research and development of a new unit for catalytic destruction of waste gases polluted mainly by volatile organic compounds (VOC), halogenated organic compounds (HOC) or carbon monoxide. Novel equipment has considerable advantages compared with commonly used arrangement (combustion chamber (catalytic reactor)-pipeline-heat exchanger). It is very compact and light and has the combustion chamber, catalytic reactor and heat exchanger integrated into one unit. Maximum utilizing heat losses in the combustion chamber and catalytic reactor is achieved. During the development of this unit experience from tests of previously developed equipment used for thermal treatment of waste gases was used, as well as from experimental studies of catalytic disposal of various VOC carried out in the newly built experimental unit. During the development calculation methods were created allowing design modifications of this unit for real industrial applications. The newly developed unit can be used in various branches of industry such as paint shops, refining plants, sewage treatment plants, food processing industry, pharmaceutical industry, but also in companies processing and transporting crude-oil or natural gas, etc

  16. Developing maintenance technologies for FBR's heat exchanger units by advanced laser processing

    International Nuclear Information System (INIS)

    Nishimura, Akihiko; Shimada, Yukihiro

    2011-01-01

    Laser processing technologies were developed for the purpose of maintenance of FBR's heat exchanger units. Ultrashort laser processing fabricated fiber Bragg grating sensor for seismic monitoring. Fiber laser welding with a newly developed robot system repair cracks on inner wall of heat exchanger tubes. Safety operation of the heat exchanger units will be improved by the advanced laser processing technologies. These technologies are expected to be applied to the maintenance for the next generation FBRs. (author)

  17. Cooperation of Horizontal Ground Heat Exchanger with the Ventilation Unit During Summer - Case Study

    Science.gov (United States)

    Romańska-Zapała, Anna; Furtak, Marcin; Dechnik, Mirosław

    2017-10-01

    Renewable energy sources are used in the modern energy-efficient buildings to improve their energy balance. One of them is used in the mechanical ventilation system ground air heat exchanger (earth-air heat exchanger - EAHX). This solution, right after heat recovery from exhaust air (recuperation), allows the reduction in the energy needed to obtain the desired temperature of supply air. The article presents the results of "in situ" measurements of pipe ground air heat exchanger cooperating with the air handling unit, supporting cooling the building in the summer season, in Polish climatic conditions. The laboratory consists of a ventilation unit intake - exhaust with rotor for which the source of fresh air is the air intake wall and two air intakes field cooperating with the tube with ground air heat exchangers. Selection of the source of fresh air is performed using sprocket with actuators. This system is part of the ventilation system of the Malopolska Laboratory of Energy-Efficient Building (MLBE) building of Cracow University of Technology. The measuring system are, among others, the sensors of parameters of air inlets and outlets of the heat exchanger channels EAHX and weather station that senses the local weather conditions. The measurement data are recorded and archived by the integrated process control system in the building of MLBE. During the study measurements of operating parameters of the ventilation unit cooperating with the selected source of fresh air were performed. Two cases of operation of the system: using EAHX heat exchanger and without it, were analyzed. Potentially the use of ground air heat exchanger in the mechanical ventilation system can reduce the energy demand for heating or cooling rooms by the pre-adjustment of the supply air temperature. Considering the results can be concluded that the continuous use of these exchangers is not optimal. This relationship is appropriate not only on an annual basis for the transitional periods (spring

  18. A Bayesian analysis of the unit root in real exchange rates

    NARCIS (Netherlands)

    P.C. Schotman (Peter); H.K. van Dijk (Herman)

    1991-01-01

    textabstractWe propose a posterior odds analysis of the hypothesis of a unit root in real exchange rates. From a Bayesian viewpoint the random walk hypothesis for real exchange rates is a posteriori as probable as a stationary AR(1) process for four out of eight time series investigated. The French

  19. Seismic soil-structure-equipment interaction analysis of unit 5/6, Kozloduy NPP

    Energy Technology Data Exchange (ETDEWEB)

    Kostov, M [Bulgarian Academy of Sciences, Central Laboratory for Seismic Mechanics and Earthquake Engineering, Sofia (Bulgaria)

    1995-07-01

    This research project is aimed to analyse problems of soil-structure-equipment interaction under seismic excitation in case of Kozloduy NPP. Reevaluation and upgrading of Kozloduy NPP has started after 1977 Vrancea earthquake. New Safe Shutdown Earthquake (SSE) level was defined, upgrading most of structural equipment was performed, seismic instrumentation was installed. New investigations were initiated after 1990 IAEA mission visited the site. A comprehensive site confirmation project was started with a subsequent structural and equipment reevaluation and upgrading. This work deals with Units 5 and 6 of WWER-1000 type only.

  20. Equipment for maintenance and repair of 900 MW PWR units in France

    International Nuclear Information System (INIS)

    Blary, F.; Castaing, C.; Haessig, M.

    1984-01-01

    As of March 1984, Electricite de France has been operating twenty-seven 900 MW PWR power units. To cut down unit unavailability and reduce the dosimetric requirements of maintenance staff, a wide range of special devices for inspecting and repairing equipment has been designed; details of 64 operational devices and a further 18 still being developed are given in a maintenance catalogue. This special equipment, together with maintenance and repair procedures, has been devised in collaboration with Framatome, the constructor of the nuclear island. One particular problem resolved was that of replacing the pins of the upper internals (UI) of 21 operational units, preventive measures having been taken at the other units. The strategy adopted consisted, first, in setting up a pin-changing workshop to enable the pins and guide tubes to be replaced separately and, second, in devising and applying wherever possible a method for partially replacing the guide tubes outside the critical path of the outage by means of a mobile pool known as the 'Aquarium'. (author)

  1. Heat exchanger cleaning

    International Nuclear Information System (INIS)

    Gatewood, J.R.

    1980-01-01

    A survey covers the various types of heat-exchange equipment that is cleaned routinely in fossil-fired generating plants, the hydrocarbon-processing industry, pulp and paper mills, and other industries; the various types, sources, and adverse effects of deposits in heat-exchange equipment; some details of the actual procedures for high-pressure water jetting and chemical cleaning of some specific pieces of equipment, including nuclear steam generators. (DN)

  2. Thermal-economic optimization of an air-cooled heat exchanger unit

    International Nuclear Information System (INIS)

    Alinia Kashani, Amir Hesam; Maddahi, Alireza; Hajabdollahi, Hassan

    2013-01-01

    Thermodynamic modeling and optimal design of an air-cooled heat exchanger (ACHE) unit are developed in this study. For this purpose, ε–NTU method and mathematical relations are applied to estimate the fluids outlet temperatures and pressure drops in tube and air sides. The main goal of this study is minimizing of two conflicting objective functions namely the temperature approach and the minimum total annual cost, simultaneously. For this purpose, fast and elitist non-dominated sorting genetic-algorithm (NSGA-II) is applied to minimize the objective functions by considering ten design parameters. In addition, a set of typical constraints, governing on the ACHE unit design, is subjected to obtain more practical optimum design points. Furthermore, sensitivity analysis of change in the objective functions, when the optimum design parameters vary, is conducted and the degree of each parameter on conflicting objective functions has been investigated. Finally, a selection procedure of the best optimum point is introduced and final optimum design point is determined. -- Highlights: ► Multi-objective optimization of air-cooled heat exchanger. ► Considering ten new design parameters in this type of heat exchanger. ► A detailed cost function is used to estimate the heat exchanger investment cost. ► Presenting a mathematical relation for optimum total cost vs. temperature approach. ► The sensitivity analysis of parameters in the optimum situation

  3. 3D web based learning of medical equipment employed in intensive care units.

    Science.gov (United States)

    Cetin, Aydın

    2012-02-01

    In this paper, both synchronous and asynchronous web based learning of 3D medical equipment models used in hospital intensive care unit have been described over the moodle course management system. 3D medical equipment models were designed with 3ds Max 2008, then converted to ASE format and added interactivity displayed with Viewpoint-Enliven. 3D models embedded in a web page in html format with dynamic interactivity-rotating, panning and zooming by dragging a mouse over images-and descriptive information is embedded to 3D model by using xml format. A pilot test course having 15 h was applied to technicians who is responsible for intensive care unit at Medical Devices Repairing and Maintenance Center (TABOM) of Turkish High Specialized Hospital.

  4. Remotely-operated equipment for inspection, measurement and handling

    CERN Document Server

    Bertone, C; CERN. Geneva. TS Department

    2008-01-01

    As part of the application of ALARA radiation dose reduction principles at CERN, inspection, measurement and handling interventions in controlled areas are being studied in detail. A number of activities which could be carried out as remote operations have already been identified and equipment is being developed. Example applications include visual inspection to check for ice formation on LHC components or water leaks, measurement of radiation levels before allowing personnel access, measurement of collimator or magnet alignment, visual inspection or measurements before fire service access in the event of fire, gas leak or oxygen deficiency. For these applications, a modular monorail train, TIM, has been developed with inspection and measurement wagons. In addition TIM provides traction, power and data communication for lifting and handling units such as the remote collimator exchange module and vision for other remotely operated units such as the TAN detector exchange mini-cranes. This paper describes the eq...

  5. 77 FR 71607 - Mobile Offshore Drilling Unit (MODU) Electrical Equipment Certification Guidance

    Science.gov (United States)

    2012-12-03

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2012-0839] Mobile Offshore Drilling... hazardous areas on foreign-flagged Mobile Offshore Drilling Units (MODUs) that have never operated, but... International Maritime Organization (IMO) Code for the Construction and Equipment of Mobile Offshore Drilling...

  6. Designing a Common Interchange Format for Unit Data Using the Command and Control Information Exchange Data Model (C2IEDM) and XSLT

    Science.gov (United States)

    2004-09-01

    Required> </Equipment> <Equipment code="L44680"> <Description>LAUNCHER GRENADE SMOKE: SCREENING RP M250 </Description> <Required...EquipmentPiecesOnHand> </UnitEquipment> <UnitEquipment> <EquipmentDescription>LAUNCHER GRENADE SMOKE: SCREENING RP M250 </EquipmentDescription

  7. He II Heat Exchanger Test Unit for the LHC Inner Triplet

    CERN Document Server

    Blanco-Viñuela, E; Huang, Y; Nicol, T H; Peterson, T; Van Weelderen, R

    2002-01-01

    The Inner Triplet Heat Exchanger Test Unit (IT-HXTU) is a 30-m long thermal model designed at Fermilab, built in US industry, fully automated and tested at CERN as part of the US LHC program to develop the LHC Interaction Region quadrupole system. The cooling scheme of the IT-HXTU is based on heat exchange between stagnant pressurized He II in the magnet cold mass and saturated He II (two-phase) flowing in a heat exchanger located outside of and parallel to the cold mass. The purposes of this test are, among others, to validate the proposed cooling scheme and to define an optimal control strategy to be implemented in the future LHC accelerator. This paper discusses the results for the heat exchanger test runs and emphasizes the thermal and hydraulic behavior of He II for the inner triplet cooling scheme.

  8. Attribute measurement systems prototypes and equipment in the United States

    International Nuclear Information System (INIS)

    Langner, D.C.; Landry, R.P.; Hsue, S.-T.; MacArthur, D.W.; Mayo, D.R.; Smith, M.K.; Nicholas, N.J.; Whiteson, R.

    2001-01-01

    Since the fall of 1997, the United States has been developing prototypical attribute verification technology for potential use by the International Atomic Energy Agency (IAEA) under the Trilateral Initiative. The first attribute measurement equipment demonstration took place in December 1997 at the Lawrence Livermore National Laboratory. This demonstration led to a series of joint Russian Federatioin/US/IAEA technical discussions that focused on attribute measurement technology that could be applied to plutonium bearing items having classified characteristics. A first prototype attribute verification system with an information barrier was demonstrated at a Trilateral Technical Workshop in June 1999 at Los Alamos. This prototype nourished further fruitful discussions between the three parties that has in turn led to the documents discussed in a previous paper. Prototype development has continued in the US, under other initiatives, using an integrated approach that includes the Trilatleral Initiative. Specifically for the Trilateral Initiative, US development has turned to some peripheral equipment that would support verifications by the IAEA. This equipment includes an authentication tool for measurement systems with information barriers and in situ probes that would facilitate inspections by reducing the need to move material out of storage locations for reverification. In this paper, we will first summarize the development of attribute verification measurement system technology in the US and then report on the status of the development of other equipment to support the Trilateral Initiative.

  9. Pre-commissioning activities of exchange units of Heavy Water Plant, Manuguru (Paper No. 1.2)

    International Nuclear Information System (INIS)

    Kamath, H.S.; Sikaria, R.P.

    1992-01-01

    Heavy Water Plant, Manuguru (HWPM) comprises of two exchange units where enrichment of deuterium from natural concentration to 15% concentration is achieved using dual temperature H 2 S-H 2 O exchange process in a three stage cascade. In each exchange unit an inventory of around 200 MT of H 2 S gas is required under normal operating pressure and a feed water flow rate of 450 MT/Hr is required to be maintained. In view of the large flow rates of H 2 S circulating gas, water, cooling water, steam etc., the lines sizes in exchange unit are quite large. Further, H 2 S gas being highly toxic and corrosive, extreme care is required in order to ensure integrity and leak tightness. While due care is taken in material selection, design, quality surveillance etc., during fabrication, certain additional measures are required to be taken during precommissioning of the systems handling H 2 S under pressure. This paper deals with the activities from completion of plant erection including hydrotesting of piping by the piping contractor to the stage of trial production run. (author)

  10. 7 CFR 3015.167 - Replacement of equipment.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Replacement of equipment. 3015.167 Section 3015.167..., DEPARTMENT OF AGRICULTURE UNIFORM FEDERAL ASSISTANCE REGULATIONS Property § 3015.167 Replacement of equipment. (a) If needed, equipment may be exchanged for replacement equipment. Replacement of equipment may be...

  11. New portable monitor enhances the ability to evaluate heat exchanger performance

    International Nuclear Information System (INIS)

    O'Toole, W.; Lacy, J.R.; Karlovich, D.N.

    1992-01-01

    Corrosion and fouling problems in nuclear power plant service water systems have led to industry-wide concern. These problems can affect the ability of these important heat exchangers to remove design heat loads. In addition, a limited amount of permanently installed on-line instrumentation is available to monitor key heat transfer parameters. A new, computerized monitoring system has been developed that acquires and manipulates process data. This enables power plant personnel to evaluate the on-line performance of important cooling system heat exchangers. The equipment provides the capability to continuously monitor, graph, and record cooling and process heat transfer parameters. The computer hardware is in a portable cabinet on wheels, which can be easily rolled from exchanger to exchanger for monitoring. This new monitoring system is being used at Consolidated Edison Company of New York Inc.'s Indian Point 2 Nuclear Station. They are currently expanding their performance testing on service water system heat exchangers and other auxiliary components to include those units that have limited on-line instrumentation. The ability to use clamp on flow and temperature sensing devices is necessary for trending exchanger performance. With on-line testing capabilities it is possible to: evaluate the cleanliness of plant heat transfer surfaces; make judgments about biofouling or antiscalant programs; and determine when equipment needs to be shut down for inspection or cleaning This paper describes this state-of-the-art equipment in detail and its application at the Indian Point 2 Nuclear Station. 9 refs., 8 figs., 1 tab

  12. Containment Response Analysis for Equipment Qualification of Kori Nuclear Power Plant Unit 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Choong Sup; Song, Dong Soo; Hwang, Yong Jun [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Seo, Kwi Hyun; Song, Wan Jung [ENERGEO Inc., Sungnam (Korea, Republic of)

    2006-07-01

    Equipment that is used to perform a necessary safety function must be capable of maintaining functional operability under all service condition postulated to occur during the installed life for the time it is required. The pressure and temperature analyses for loss of coolant accident and main steam line break accident provide the bounding test envelope inside containment for the operability evaluation of safety equipment in harsh environmental. This paper describes the results of the containment pressure and temperature analysis for the equipment qualification (EQ) envelopes of Kori unit 3 and 4.

  13. Condition based monitoring, diagnosis and maintenance on operating equipments of a hydraulic generator unit

    International Nuclear Information System (INIS)

    Liu, X T; Feng, F Z; Si, A W

    2012-01-01

    According to performance characteristics of operating equipments in a hydraulic generator unit (HGU), the relative techniques on condition monitoring and fault diagnosis (CMFD) are introduced in this paper, especially the key technologies are emphasized, such as equipment monitoring, expert system (ES), intelligent diagnosis and condition based maintenance (CBM). Meanwhile, according to the instructor on CBM proposed by State electric power corporation, based on integrated mode, the main steps on implementation of CBM are discussed in this paper.

  14. DESIGNING FEATURES OF POWER OPTICAL UNITS FOR TECHNOLOGICAL EQUIPMENT

    Directory of Open Access Journals (Sweden)

    M. Y. Afanasiev

    2016-03-01

    Full Text Available This paper considers the question of an optical unit designing for transmitting power laser radiation through an optical fiber. The aim of this work is designing a simple construction unit with minimized reflection losses. The source of radiation in the optical unit described below is an ultraviolet laser with diode pumping. We present the general functioning scheme and designing features for the three main parts: laser beam deflecting system, laser beam dump and optical unit control system. The described laser beam deflection system is composed of a moving flat mirror and a spherical scattering mirror. Comparative analysis of the production technology for such mirrors was carried out, and, as a result, the decision was made to produce both mirrors of 99.99 % pure molybdenum without coating. A moving mirror deflects laser emission from a source through a fiber or deflects it on a spherical mirror and into the laser beam dump, moreover, switching from one position to another occurs almost immediately. It is shown that a scattering mirror is necessary, otherwise, the absorbing surface of the beam dump is being worn out irregularly. The laser beam dump is an open conical cavity, in which the conical element with its spire turned to the emission source is placed. Special microgeometry of the internal surface of the beam dump is suggested for the better absorption effect. An optical unit control system consists of a laser beam deflection system, laser temperature sensor, deflection system solenoid temperature sensor, and deflection mirror position sensor. The signal processing algorithm for signals coming from the sensors to the controller is described. The optical unit will be used in special technological equipment.

  15. Radon mitigation with mechanical supply and exhaust ventilation adjusted by a pressure control unit

    International Nuclear Information System (INIS)

    Kokotti, H.; Keskikuru, T.; Kalliokoski, P.

    1993-01-01

    Effective ventilation and positive or low negative pressure indoors are suggested to low indoor radon levels. The aim of this study is to develop and to test an equipment, which makes it possible to achieve simultaneously effective ventilation and minimum outdoor-pressure difference. The unit includes mechanical supply and exhaust air fans, a exchanger and a pressure control unit in direct digital control (DDC), which adjusts continuously air exchange based on the pressure difference transmitter information. (orig.). (8 refs., 6 figs.)

  16. Traveling Uncharted Waters: The Exchange of Government Information between the United States and China.

    Science.gov (United States)

    Wang, Rui

    1998-01-01

    Describes a program established between the United States and China for exchange of government publications through their national libraries, the Library of Congress and the National Library of China. Challenges to the program, including the shift to electronic formats in the United States and government Internet censorship in China, are…

  17. Unit of Account, Medium of Exchange, and Prices

    OpenAIRE

    Young Sik Kim; Manjong Lee

    2011-01-01

    The separation of a unit of account (UoA) from a medium of exchange (MoE) in the commodity-money system is investigated by considering explicitly a seller¡¯s choice with regard to posting price in terms of either an MoE or a UoA. If the likelihood of debasement of MoE or its rate is high enough and agents are sufficiently risk averse, there exists a monetary equilibrium in which price is quoted in terms of a UoA. Further, a UoA-posting equilibrium yields the flexible nominal price, whereas ...

  18. 47 CFR 36.126 - Circuit equipment-Category 4.

    Science.gov (United States)

    2010-10-01

    ... separating property associated with special services, circuit equipment included in Categories 4.12 (other... Equipment Excluding Wideband—Category 4.13—The cost of Circuit Equipment associated with exchange line plant... 47 Telecommunication 2 2010-10-01 2010-10-01 false Circuit equipment-Category 4. 36.126 Section 36...

  19. Calculational-experimental examination and ensuring of equipment and pipelines seismic resistance at starting and operating water-cooled WWER-type reactor NPPs. Final report. From 01 May 1997 - 30 April 1998

    International Nuclear Information System (INIS)

    Kaznovski, S.

    1999-01-01

    In conformity with request from Paks NPP in July 1997 the additional dynamic tests of the following units of equipment were carried out: Heat exchanger (Diesel Generator Station); Jalousie (Diesel Generator Station); Axial ventilator (Main Building, gallery of electric equipment). The natural frequencies of equipment were obtained as results of these testing. For all tested units the calculations of seismic resistance were carried out. The method of finite elements and special computer programmes of KBGU (ISPA, and others) were used. Calculations were carried out in accordance with modem standards. The calculations of tested equipment seismic resistance are carried out based on the obtained experimental data and NPP floor response spectra. The necessary recommendations for unsatisfactory equipment are worked out

  20. Plasma exchange in the intensive care unit: Technical aspects and complications.

    Science.gov (United States)

    Lemaire, Aurélie; Parquet, Nathalie; Galicier, Lionel; Boutboul, David; Bertinchamp, Rémi; Malphettes, Marion; Dumas, Guillaume; Mariotte, Eric; Peraldi, Marie-Noëlle; Souppart, Virginie; Schlemmer, Benoit; Azoulay, Elie; Canet, Emmanuel

    2017-12-01

    Data on plasma exchange therapy in the intensive care unit (ICU) setting are scarce. We aimed to describe the technical aspects and the adverse events associated with the procedure in critically ill patients. All adult patients treated by plasma exchange in the medical ICU of the Saint-Louis university hospital between January 1, 2013 and March 31, 2015 were prospectively included. We report on 260 plasma exchange procedures performed in 50 patients. The centrifugation technique was used for 159 (61%) procedures and the filtration technique for the other 101 (39%) procedures. Both techniques had similar efficacy to treat hyperviscosity syndrome (n = 18). Seventy (26.9%) of the 260 plasma exchange procedures were reported with at least one adverse reaction. Centrifugation and filtration techniques had similar rates of adverse reactions (23.9 vs. 31.7%, P = .19). Hypotension was the most reported (n = 21, 8%) and correlates with a low hematocrit before therapy. Most complications were related to allergic reactions to the replacement fluids. Coagulation disorders depended on the type of replacement fluid. The post-exchange fibrinogen level was decreased by 54% [48;66] with albumin 5%, and 4% [-5;17] with plasma frozen within 24 h. Twenty-three (22.8%) of the 101 filtration procedures experienced filter clotting. Filter clotting was associated with a higher volume exchange prescribed when compared to procedures without filter clotting (4600 [4000;5000] ml vs. 3900 [3600;4800] ml, P < .01). Plasma exchange is a relatively safe and generally well-tolerated procedure in the ICU setting. Most adverse events are unpredictable and related to minor allergic reactions. © 2017 Wiley Periodicals, Inc.

  1. Reconciliation of equipment flexibility effects on piping system dynamic response

    International Nuclear Information System (INIS)

    Geraets, L.H.

    1987-01-01

    Piping systems are connected to equipment; if the equipment cannot be considered as ''rigid'' relative to excitation frequencies, nozzle response spectra techniques, or equipment modeling techniques are used. If the equipment is considered rigid, a fixed anchor is assumed. However, occasionally after (seismic) dynamic analysis has been completed, tests or detailed equipment dynamic analyses demonstrate that the assumption of ''infinite stiff'' is questionable. This paper reviews several classes of equipment (pumps, vessels, reservoirs, heat exchangers), and the associated (piping stresses, support loads, equipment nozzle allowables). Significant divergences between design and ''as built'' results are shown (for heat exchangers in particular). The paper discusses the reconciliation process performed for a belgian PWR plant through the use of less conservative seismic damping data (Code Case N-411)

  2. Comparison between conventional heat exchanger performance and an heat pipes exchanger

    International Nuclear Information System (INIS)

    Souza, J.R.G. de; Rocha, N.R.

    1989-01-01

    The thermal performance of conventional compact heat exchanger and of exchanger with heat pipes are simulated using a digital computer, for equal volumes and the same process conditions. The comparative analysis is depicted in graphs that indicate which of the situations each equipment is more efficient. (author)

  3. HYDRAULIC UNITS FOR DRIVING SYSTEMS OF RUNNING EQUIPMENT IN ROAD CONSTRUCTION MACHINERY

    Directory of Open Access Journals (Sweden)

    A. Ja. Kotlobai

    2016-01-01

    Full Text Available Operational efficiency of multi-functional road construction machines depends on number of working bodies which are simultaneously performing technological operations. Systems for propulsion pto to the running equipment drive and active working bodies of road construction machines are developing in the way of using three-axis hydraulic drives. When designing a hydraulic system for road construction machinery dividing of power flow from propulsion to the running equipment drive and active working bodies is considered as rather essential problem. Leading companies do not pay attention to the development of flow divider designs, preferring to produce more expensive multi-flow pumps. One of the ways to increase efficiency of multi-functional road construction machinery is an implementation of running equipment hydraulic driving system based on a mono-aggregate pump unit which consists of a pump and a volumetric divider of power fluid flow. A principle of volumetric division and summing-up of power fluid flows, technical realization and methodology for calculation of key parameters of discrete flow distributors has been developed on the basis of discrete hydraulics regulations. The paper presents results of mathematical modeling of hydraulic systems equipped with the discrete flow distributor. Analysis of a dual-motor hydraulic drive operation has shown the following results: a discrete flow distributor ensures independent load mode of the current consumer circuit operation from the load mode of the second consumer circuit within a wide range of loads; rational value of working fluid flow discretization parameter is the following value interval k = 4–6, maximum value of parameter efficiency is reached when an angular velocity of a distributor rotor coincides with the angular velocity of a pump shaft; discrete flow distributor provides a possibility to change parameters of hydraulic flow feeding in consumers’ pressure lines within a wide range

  4. Computer aided heat transfer analysis in a laboratory scaled heat exchanger unit

    International Nuclear Information System (INIS)

    Gunes, M.

    1998-01-01

    In this study. an explanation of a laboratory scaled heat exchanger unit and a software which is developed to analyze heat transfer. especially to use it in heat transfer courses, are represented. Analyses carried out in the software through sample values measured in the heat exchanger are: (l) Determination of heat transfer rate, logarithmic mean temperature difference and overall heat transfer coefficient; (2)Determination of convection heat transfer coefficient inside and outside the tube and the effect of fluid velocity on these; (3)Investigation of the relationship between Nusselt Number. Reynolds Number and Prandtl Number by using multiple non-linear regression analysis. Results are displayed on the screen graphically

  5. Equipment for inspection and carrying out repairs, if required, for tube bundles of steam raising units

    International Nuclear Information System (INIS)

    Gugel, G.

    1976-01-01

    The equipment solves the problem of being able to inspect and possibly to repair U-tubes of a vertical steam raising unit standing on a tube floor, without draining the primary medium and bringing the test equipment and tools into the inside of the boiler first. This is achieved by leaving a considerable part of the equipment permanently in the hemispherical space under the tube floor and operating it from the outside, on the other side of the concrete shielding. An inspection tube is threaded in turn horizontally through a concrete shield, a tube duct in the heat insulation of the steam raising unit, and through a hole in the hemispherical space under the tube floor into this space. The end of an angle tube can be moved axially from outside the concrete shield and can be rotated in a semicircle above the tube axis. By interposing a, for example, 12 part distributor with 12 short, differently bent tubes 12 adjacent tubes opening into the tube floor can be controlled and tested, by axial movement of the angle tube together with the distributor, e.g. 4 x 12 other U tubes. A turbulent flow sensor, for example, can be introduced through the angle tube and distributor. In the non-operational condition the equipment is moved into a recess via a supporting angle and stopped there. (ORU) [de

  6. Notice to exporters on products prohibited from export (nuclear material, equipment and large nuclear units)

    International Nuclear Information System (INIS)

    1988-01-01

    In order to ensure that the policy to avoid the proliferation of nuclear weapons is complied with, the French Administration applies stricter controls over the export of certain sensitive products, materials and equipment. To this effect, lists of such products, materials and equipment are published in the form of Notices to exporters and periodically revised. This Notice repeals and replaces the previous Notice published in the Official Gazette of 21 January 1986. Annex I contains the list of materials whose export is subject to nuclear non-proliferation controls. Annex II lists the equipment whose export is subject to the same controls. Annex III includes the list of large nuclear units for which an application for prior approval of export must be submitted to the Administrations concerned. (NEA) [fr

  7. The history of anaesthetic equipment evaluation in the United Kingdom: lessons for developing future strategy.

    Science.gov (United States)

    Wilkes, A R; Pandit, J J; O'Sullivan, E

    2011-12-01

    Recent guidance published by the Association of Anaesthetists of Great Britain and Ireland encourages the purchase of equipment based on evidence of safety and performance. For many years, evidence of the safety and performance of anaesthetic equipment was published by various government departments and agencies. However, these schemes were gradually eroded over time such that many devices entered the market with little or no clinical evidence of their efficacy. This recently led to the Difficult Airway Society's issuing guidance to its members on how best to select new airway devices; guidance that was based on the available evidence. This article provides a short history of the evaluation of anaesthetic equipment in the United Kingdom. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  8. Earth Observing System (EOS)/ Advanced Microwave Sounding Unit-A (AMSU-A): Special Test Equipment. Software Requirements

    Science.gov (United States)

    Schwantje, Robert

    1995-01-01

    This document defines the functional, performance, and interface requirements for the Earth Observing System/Advanced Microwave Sounding Unit-A (EOS/AMSU-A) Special Test Equipment (STE) software used in the test and integration of the instruments.

  9. United States/Mexico electricity exchanges. [History, incentives, and constraints

    Energy Technology Data Exchange (ETDEWEB)

    None,

    1980-05-01

    As a result of the agreement between the respective presidents, a joint study was undertaken to analyze the possibilities of increasing the international electricity exchange between the two countries. Responsibility for this undertaking was assigned to the United States Department of Energy (DOE) and to the Direccion de Energia de Mexico (DEM) through the Comision Federal de Electricidad (CFE). Representatives from Mexico and the US were chosen from the regional utilities along the border between the two countries and made up working groups that particiated in the study. With the support of both governments, and a high degree of cooperation between the two countries, work on the study was completed within fourteen months The completion of the study has been a major step in broadening the base of bilateral energy relations. the study highlights the opportunities for increased electricity exchanges, which could increase cooperation along the common border. Expansion of electricity interchange could offer substantial economic benefit to both countries, both directly and indirectly. Direct benefits include increased reliability of electric power and cost savings through economies of scale and diversity of peak demand patterns. Indirect benefits include improved economic and employment opportunities, especially in the border areas of both countries. This report provides background on the history of past exchanges and the characteristics of the US and Mexico electric systems, a summary of opportunities and incentives, and suggestions for procedures to remove obstacles and constraints.

  10. Analysis of the heat transfer in double and triple concentric tube heat exchangers

    Science.gov (United States)

    Rădulescu, S.; Negoiţă, L. I.; Onuţu, I.

    2016-08-01

    The tubular heat exchangers (shell and tube heat exchangers and concentric tube heat exchangers) represent an important category of equipment in the petroleum refineries and are used for heating, pre-heating, cooling, condensation and evaporation purposes. The paper presents results of analysis of the heat transfer to cool a petroleum product in two types of concentric tube heat exchangers: double and triple concentric tube heat exchangers. The cooling agent is water. The triple concentric tube heat exchanger is a modified constructive version of double concentric tube heat exchanger by adding an intermediate tube. This intermediate tube improves the heat transfer by increasing the heat area per unit length. The analysis of the heat transfer is made using experimental data obtained during the tests in a double and triple concentric tube heat exchanger. The flow rates of fluids, inlet and outlet temperatures of water and petroleum product are used in determining the performance of both heat exchangers. Principally, for both apparatus are calculated the overall heat transfer coefficients and the heat exchange surfaces. The presented results shows that triple concentric tube heat exchangers provide better heat transfer efficiencies compared to the double concentric tube heat exchangers.

  11. A hardware-software system for the automation of verification and calibration of oil metering units secondary equipment

    Science.gov (United States)

    Boyarnikov, A. V.; Boyarnikova, L. V.; Kozhushko, A. A.; Sekachev, A. F.

    2017-08-01

    In the article the process of verification (calibration) of oil metering units secondary equipment is considered. The purpose of the work is to increase the reliability and reduce the complexity of this process by developing a software and hardware system that provides automated verification and calibration. The hardware part of this complex carries out the commutation of the measuring channels of the verified controller and the reference channels of the calibrator in accordance with the introduced algorithm. The developed software allows controlling the commutation of channels, setting values on the calibrator, reading the measured data from the controller, calculating errors and compiling protocols. This system can be used for checking the controllers of the secondary equipment of the oil metering units in the automatic verification mode (with the open communication protocol) or in the semi-automatic verification mode (without it). The peculiar feature of the approach used is the development of a universal signal switch operating under software control, which can be configured for various verification methods (calibration), which allows to cover the entire range of controllers of metering units secondary equipment. The use of automatic verification with the help of a hardware and software system allows to shorten the verification time by 5-10 times and to increase the reliability of measurements, excluding the influence of the human factor.

  12. Determining the Residual Lifetime of Qualified Electrical and I and C Equipment in Units 5 and 6 of Kozloduy NPP

    International Nuclear Information System (INIS)

    Radoslavov, Biser

    2012-01-01

    The proposed paper clarifies the environmental qualification and residual lifetime of installed equipment and electrical cables in operating WWER 1000 type units 5 and 6 of Kozloduy NPP. The qualification approach is a combination of analyses and tests in consideration of some specific features of WWER equipment. As a result of the study, selected equipment is divided in 26 groups. Qualification groups include similar types of equipment with equal resistance to foreign impacts, analogous critical parts, and same methods of control and estimation of residual lifetime. Qualification protocols were made for each group. (author)

  13. Automatic exchange unit for control rod drive device

    International Nuclear Information System (INIS)

    Nasu, Seiji; Sasaki, Masayoshi.

    1982-01-01

    Purpose: To enable automatic reoperation and continuation without external power interruption remedy device at the time of recovering the interrupted power soruce during automatic positioning operation. Constitution: In case of an automatic exchange unit for a control rod drive device of the control type for setting the deviation between the positioning target position and the present position of the device to zero, the position data of the drive device of the positioning target value of the device is automatically read, and an interlock of operation inhibit is applied to a control system until the data reading is completed and automatic operation start or restart conditions are sequentially confirmed. After the confirmation, the interlock is released to start the automatic operation or reoperation. Accordingly, the automatic operation can be safely restarted and continued. (Yoshihara, H.)

  14. Modeling of crude oil fouling in preheat exchangers of refinery distillation units

    Energy Technology Data Exchange (ETDEWEB)

    Jafari Nasr, Mohammad Reza; Majidi Givi, Mehdi [National Petrochemical Research and Technology Company (NPC-RT), P.O. Box 14385, Tehran (Iran)

    2006-10-15

    The aim of this paper is to propose a new model for crude oil fouling in preheat exchangers of crude distillation units. The experimental results of Australian light crude oil with the tube side surface temperature between 200 and 260{sup o}C and fluid velocity ranged 0.25-0.4m/s were used [Z. Saleh, R. Sheikholeslami, A.P. Watkinson, Heat exchanger fouling by a light australian crude oil, in: Heat Exchanger Fouling and Cleaning Fundamentals and Applications, Santa Fe, 2003]. The amount of activation energy depends on the surface temperature has been calculated. A new model including a term for fouling formation and a term for fouling removal due to chemical and tube wall shear stress was proposed, respectively. The main superiority of the model are independent to Pr number, thermal fouling removal and determination of {beta} based on experimental tests. Finally using the proposed model the fouling rate of Australian light crude oil has been calculated and the threshold curves to identify fouling and no fouling formation zones have been drawn. (author)

  15. Experimental analysis of an air–water heat pump with micro-channel heat exchanger

    International Nuclear Information System (INIS)

    Brignoli, Riccardo; Cecchinato, Luca; Zilio, Claudio

    2013-01-01

    A multi-port extruded (MPE) aluminium flat tube air heat exchanger was compared to a round tube finned coil (FC). The MPE heat exchanger has parallel flow vertical tube configuration with headers in horizontal position and conventional folded louvred fins. The two heat exchangers were mounted on a 10 kW cooling capacity R410A packaged air heat pump. They were sized to approximately obtain the same cooling and heating capacities in chiller and heating mode, respectively. Climatic room steady state tests without frosting phenomena occurring during heat pump operation, demonstrated that the round tube and the flat tube heat exchanger performance are comparable. The MPE heat exchanger was tested with different refrigerant inlet distributor/outlet tubes configurations to investigate the effect of liquid refrigerant distribution. Cycling frosting/defrosting operations were tested with two equivalent machines placed in parallel outdoor and working at full load condition, one of the units was equipped with the MPE heat exchanger while the other mounted a standard finned coil. Penalization factors were analytically introduced to evaluate frosting associated heating energy and energy efficiency degradation. Test results indicate that both the heat pumps are penalized by frost formation but both the penalization factors are higher for the MPE-unit than the FC-unit one in the −6 to 4 °C air dry bulb temperature range. For the two units, a roughly linear dependence of the heating energy penalization factor and of the energy efficiency factor from the difference between outdoor air and saturated air at the evaporation temperature humidity ratio can be pointed out. - Highlights: ► A multi-port aluminium flat tube heat exchanger was compared to a round tube finned one in a heat pump application. ► In steady state tests without frosting the round and the flat tube heat exchanger are comparable. ► Different inlet distributor/outlet tubes configurations were tested to

  16. High temperature heat exchange: nuclear process heat applications

    International Nuclear Information System (INIS)

    Vrable, D.L.

    1980-09-01

    The unique element of the HTGR system is the high-temperature operation and the need for heat exchanger equipment to transfer nuclear heat from the reactor to the process application. This paper discusses the potential applications of the HTGR in both synthetic fuel production and nuclear steel making and presents the design considerations for the high-temperature heat exchanger equipment

  17. New type fuel exchange system

    International Nuclear Information System (INIS)

    Meshii, Toshio; Maita, Yasushi; Hirota, Koichi; Kamishima, Yoshio.

    1988-01-01

    When the reduction of the construction cost of FBRs is considered from the standpoint of the machinery and equipment, to make the size small and to heighten the efficiency are the assigned mission. In order to make a reactor vessel small, it is indispensable to decrease the size of the equipment for fuel exchange installed on the upper part of a core. Mitsubishi Heavy Industries Ltd. carried out the research on the development of a new type fuel exchange system. As for the fuel exchange system for FBRs, it is necessary to change the mode of fuel exchange from that of LWRs, such as handling in the presence of chemically active sodium and inert argon atmosphere covering it and handling under heavy shielding against high radiation. The fuel exchange system for FBRs is composed of a fuel exchanger which inserts, pulls out and transfers fuel and rotary plugs. The mechanism adopted for the new type fuel exchange system that Mitsubishi is developing is explained. The feasibility of the mechanism on the upper part of a core was investigated by water flow test, vibration test and buckling test. The design of the mechanism on the upper part of the core of a demonstration FBR was examined, and the new type fuel exchange system was sufficiently applicable. (Kako, I.)

  18. 36 CFR 1207.32 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... 1207.32 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION GENERAL RULES... as follows: (1) Items of equipment with a current per-unit fair market value of less than $5,000 may...) Items of equipment with a current per unit fair market value in excess of $5,000 may be retained or sold...

  19. Evaluating the Effectiveness and the Impact of Donated Neurosurgical Equipment on Neurosurgical Units in Low- and Middle-Income Countries: The World Federation of Neurosurgical Societies Experience.

    Science.gov (United States)

    Venturini, Sara; Park, Kee B

    2018-01-01

    Surgical practice highly depends on the availability of surgical equipment; this is particularly relevant to low- and middle-income countries (LMICs), where resources are limited. A key part of the efforts to improve surgical provision globally include providing affordable equipment to LMICs; however, the effectiveness and the impact of these initiatives have not yet been assessed. We aimed to evaluate the World Federation of Neurosurgical Societies neurosurgical equipment program in this context. Recipients were identified from the World Federation of Neurosurgical Societies records; contact details were gathered. An online survey was used to collect data on equipment, including its current use, any malfunctioning issues, suitability, reliability, serviceability, and the impact it has had on the unit. Responses were received from 16 units, totaling 28 pieces of equipment. A total of 75% of the equipment is still in use; of this, 57% is fully functioning, and 43% is used despite some malfunction. We found that 25% of the equipment is broken and unusable; high-maintenance items, such as high-speed drills, feature in this category (100% broken, n = 3). Units reported an increase in number of operation performed in 74% cases, improved surgery quality in 78%, and breadth of operations in 44%. Satisfaction, equipment suitability, reliability, and serviceability scored highly, with median values of 9 for all fields on a 10-point scale. Equipment donation positively impacts neurosurgical units in LMICs by allowing expansion of neurosurgical practice, improved safety and quality, and affordability. Adequate follow-up, considerations regarding equipment durability and maintenance needs, and improved support for repairs should be prioritized to ensure maximal benefit. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. A comparison of portable ultrasound and fully-equipped clinical ultrasound unit in the thyroid size measurement of the Indo-Pacific bottlenose dolphin.

    Directory of Open Access Journals (Sweden)

    Brian C W Kot

    Full Text Available Measurement of thyroid size and volume is a useful clinical parameter in both human and veterinary medicine, particularly for diagnosing thyroid diseases and guiding corrective therapy. Procuring a fully-equipped clinical ultrasound unit (FCUS may be difficult in most veterinary settings. The present study evaluated the inter-equipment variability in dolphin thyroid ultrasound measurements between a portable ultrasound unit (PUS and a FCUS; for both units, repeatability was also assessed. Thyroid ultrasound examinations were performed on 15 apparently healthy bottlenose dolphins with both PUS and FCUS under identical scanning conditions. There was a high level of agreement between the two ultrasound units in dolphin thyroid measurements (ICC = 0.859-0.976. A high intra-operator repeatability in thyroid measurements was found (PUS: ICC = 0.854-0.984, FCUS: ICC = 0.709-0.954. As a conclusion, no substantial inter-equipment variability was found between PUS and FCUS in dolphin thyroid size measurements under identical scanning conditions, supporting further application of PUS for quantitative analyses of dolphin thyroid gland in both research and clinical practices at aquarium settings.

  1. The Kozloduy project management unit

    International Nuclear Information System (INIS)

    Carnes, W.S.; Gros-Gean, P.; Demireva, E.

    2004-01-01

    The Project Management Unit (PMU) has been established in support to the Kozloduy NPP decommissioning department. It is comprised of a Consortium of the British Nuclear Group, EDF and subcontractor ENPRO Consult. It is responsible for the management of seven projects (a facility for dry storage of spent fuel; equipment to treat low activity liquid radioactive waste; provision of physical separation of the plant systems and areas to be decommissioned from the ones in operation; equipment to decontaminate and clean pools and large tanks; a facility to provide high volume reduction of solid radioactive wastes and retrieval and conditioning of ion exchange resins and other sorbents; equipment to provide measurement for the free-release of materials and components; a facility for personnel monitoring, decontamination and clothes changing for work outside of the normal radiological control areas) that will be used in support of the KNPP decommissioning process. The projects will be tendered in compliance with the European Bank for Reconstruction and Development requirements

  2. The AP1000{sup R} China projects move forward to construction completion and equipment installation

    Energy Technology Data Exchange (ETDEWEB)

    Harrop, G. [Westinghouse Electric Company LLC, 1000 Westinghouse Drive, Cranberry Township, PA 16066 (United States)

    2012-07-01

    The AP1000 design is the only Generation III+ technology to receive design certification from the U.S. Nuclear Regulatory Commission. This evolutionary design provides the highest safety and performance standards and has several distinct advantages over other designs, including improved operations and reduced construction schedule risks through the use of modern, modular, engineering principles that allow construction and fabrication tasks traditionally performed in sequence to be undertaken in parallel. Since the first granting of Design Certification in 2005 by the NRC, the AP1000 design has been modified to meet emergent NRC requirements such as those requiring the design to withstand the impact of an aircraft crash. Both domestic and foreign utilities have turned to the Westinghouse AP1000 plant design to meet their near - and long-term sustainable energy needs. The first ever deployment of this advanced U.S. nuclear power technology began in China in 2007 with the award of a contract to build four AP1000 units, constructed in pairs at the coastal sites of Sanmen (Zhejiang Province) and Haiyang (Shandong Province). Currently, all four units are at an advanced stage of construction. The commercial operation date for Sanmen Unit 1 is November 2013 followed by Haiyang Unit 1 being operational in May 2014. Construction and equipment manufacture is at an advanced stage. Sanmen Unit 1 equipment that has been delivered includes the reactor vessel, the reactor vessel closure head, the passive residual heat removal heat exchanger, the integrated head package, the polar crane, and the refueling machine. The steam generators are also completed. The RV was installed within the containment vessel building in September 2011. The installation of this major equipment will allow the setting of the containment vessel top head. Haiyang Unit 1 is also achieving significant progress. Significant benefits continue to be realized as a result of lessons learned and experience gained

  3. Geography of community health information organization activity in the United States: Implications for the effectiveness of health information exchange.

    Science.gov (United States)

    Vest, Joshua R

    The United States has invested nearly a billion dollars in creating community health information organizations (HIOs) to foster health information exchange. Community HIOs provide exchange services to health care organizations within a distinct geographic area. While geography is a key organizing principle for community HIOs, it is unclear if geography is an effective method for organization or what challenges are created by a geography-based approach to health information exchange. This study describes the extent of reported community HIO coverage in the United States and explores the practical and policy implications of overlaps and gaps in HIO service areas. Furthermore, because self-reported service areas may not accurately reflect the true extent of HIOs activities, this study maps the actual markets for health services included in each HIO. An inventory of operational community HIOs that included self-reported geographic markets and participating organizations was face-validated using a crowd-sourcing approach. Aggregation of the participating hospitals' individual health care markets provided the total geographic market served by each community HIO. Mapping and overlay analyses using geographic information system methods described the extent of community HIO activity in the United States. Evidence suggests that community HIOs may be inefficiently distributed. Parts of the United States have multiple, overlapping HIOs, while others do not have any providing health information exchange services. In markets served by multiple community HIOs, 45% of hospitals were participants of only one HIO. The current geography of community HIO activity does not provide comprehensive patient information to providers, nor community-wide information for public health agencies. The discord between the self-reported and market geography of community HIOs raises concerns about the potential effectiveness of health information exchange, illustrates the limitations of geography as

  4. Marrying Up by Marrying Down: Status Exchange between Social Origin and Education in the United States.

    Science.gov (United States)

    Schwartz, Christine R; Zeng, Zhen; Xie, Yu

    2016-11-01

    Intermarriage plays a key role in stratification systems. Spousal resemblance reinforces social boundaries within and across generations, and the rules of intermarriage govern the ways that social mobility may occur. We examine intermarriage across social origin and education boundaries in the United States using data from the 1968-2013 Panel Study of Income Dynamics. Our evidence points to a pattern of status exchange-that is, persons with high education from modest backgrounds tend to marry those with lower education from more privileged backgrounds. Our study contributes to an active methodological debate by pinpointing the conditions under which the results pivot from evidence against exchange to evidence for exchange and advances theory by showing that the rules of exchange are more consistent with the notion of diminishing marginal utility than the more general theory of compensating differentials.

  5. Evaluation of the quality parameters of mobile X-ray units equipment used for radiodiagnostic in public institutions of Sergipe

    International Nuclear Information System (INIS)

    Oliveira, Celso A.; Santos, Lucas R. dos; Silva, Fabio A.R.; Souza, Divanizia N.

    2008-01-01

    This project was started having as main objective to observe the diagnosis quality offered by mobile x-ray units utilized in a health care institution. In this work we are reporting the first results obtained from three equipment used by a public institution inspected on the state of Sergipe, Brazil. During the verification visits at institution the radiology technicians were questioned about specific maintenances performed on the equipment and the operating procedures used. Moreover, some beams parameters were verified as dose, dose rate, and peak voltage and exposition time. The obtained results showed a good index of reproducibility and linearity of the operation parameters, of the kerma air rate and exposition time. However, to the kVp tests were observed variations up to 20% between the nominal value used and the value measured on the X-ray units. The test results of the focal point are in accordance with the acceptable standards. The analyses of equipment and the answered questionnaire showed that have not been performed periodic maintenances in the equipment, therefore some of the equipment do not present satisfactory requirements of operating, their do not make use of luminous field nether collimator or the scale meter to checking the source to surface distance. The main factor that can explains the negative results is the absence of a continue quality program associated with the unsatisfactory maintenances. The health care institutions evaluated are introducing a permanent quality program to the X-ray devices. (author)

  6. Nuclear safety inspection in treatment process for SG heat exchange tubes deficiency of unit 1, TNPS

    International Nuclear Information System (INIS)

    Zhang Chunming; Song Chenxiu; Zhao Pengyu; Hou Wei

    2006-01-01

    This paper describes treatment process for SG heat exchange tubes deficiency of Unit 1, TNPS, nuclear safety inspection of Northern Regional Office during treatment process for deficiency and further inspection after deficiency had been treated. (authors)

  7. The outline of the processes for lithium isotope separation by ion exchange method

    International Nuclear Information System (INIS)

    Fujine, Sachio; Saito, Keiichiro; Naruse, Yuji; Shiba, Koreyuki; Kosuge, Masao; Itoi, Toshiaki; Kitsukawa, Tomohiko.

    1981-10-01

    A plant of lithium isotope separation by displacement chromatography is preliminary designed. The construction expenses of a 100 kg 7 Li/year plant and the unit cost of separation are estimated on the basis of the data taken from the literature, and the feasibility is studied. Experimental equipment of continuous displacement chromatography is set up and is tested with the stable automatic operation. These results indicate that the ion exchange method is promising for industrial lithium isotope separation. (author)

  8. Equipment performance and radiation protection status in X-ray fluoroscopy units in Sudan

    International Nuclear Information System (INIS)

    Ahmed, N. A.; Nayl, A. I.; Suliman, I. I.

    2012-01-01

    The number of fluoroscopy and fluoroscopically guided procedures has been substantially growing in developing countries at the same time advanced and sophisticated equipment are used in some hospitals. However, radiation protection requirements are not necessarily well adopted. In this study nine fluoroscopy X-ray units in Sudan were examined for compliance with international standards. The tests included: beam quality, entrance surface air kerma, image quality and radiation field measurements. Staff radiation protection tools such as lead aprons and eye glasses were also visually examined to find out whether international recommendations were fulfilled and to determine the level of staff awareness. The measured peak tube voltage deviation exceeded the recommended tolerance level in 30 % of the measurements. The results of patient doses measurements exceeded the recommended reference dose levels in 43 % of the measurements; however image quality and radiation field generally fulfilled the requirements for most units. The study revealed that a considerable number of fluoroscopy units were not performing according to the international standards and highlights the need of optimisation of radiation protection. (authors)

  9. Comparison between Japan and the United States in the frequency of events in equipment and components at nuclear power plants

    International Nuclear Information System (INIS)

    Shimada, Yoshio

    2007-01-01

    The Institute of Nuclear Safety System, Incorporated (INSS) conducted trend analyses until 2005 to compare the frequency of events in certain electrical components and instrumentation components at nuclear power plants between Japan and the United States. The results revealed that events have occurred approximately an order of magnitude less often in Japan than in the United States. This paper compared Japan and the United States in more detail in terms of how often events - events reported under the reporting standards of the Nuclear Information Archive (NUCIA) or the Institute of Nuclear Power Operations (INPO) - occurred in electrical components, instrumentation components and mechanical components at nuclear power plants. The results were as follows: (1) In regard to electrical components and instrumentation components, events have occurred one-eighth less frequently in Japan than in the United States, suggesting that the previous results were correct. (2) Events have occurred more often in mechanical components than electrical components and instrumentation components in both Japan and the United States, and there was a smaller difference in the frequency of events in mechanical components between the two countries. (3) Regarding mechanical components, it was found that events in the pipes for critical systems and equipment, such as reactor coolant systems, emergency core cooling systems, instrument and control systems, ventilating and air-conditioning systems, and turbine equipment, have occurred more often in Japan than in the United States. (4) The above observations suggest that there is little scope for reducing the frequency of events in electrical components and instrumentation components, but that mechanical components such as pipes for main systems like emergency core cooling systems and turbine equipment in the case of PWRs, could be improved by re-examining inspection methods and intervals. (author)

  10. Report on coal refining and chemical equipment analogous to coal liquefaction equipment in fiscal 1981. Maintenance of equipment for direct desulfurization, indirect desulfurization, and fluidized catalytic cracking; 1981 nendo sekitan ekika ruiji seiyu seisei oyobi kagaku sochi ni kansuru chosa hokokusho. Chokudatsu, kandatsu, ryudo sesshoku bunkai sochi no hozen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1981-07-01

    This questionnaire survey was intended to investigate the actual state of maintenance such as materials used, conditions for use, anti-corrosion measures, and cases and handling of damage, concerning primary apparatus in the direct/indirect desulfurization equipment and the fluidized catalytic crackers, which are owned by each oil refinery and which are analogous to coal liquefaction equipment. The questionnaire was intended for the following equipment and apparatus, with the actual state of their maintenance investigated. 1. Questionnaire concerning maintenance of direct desulfurization (reactor, high temperature separation tank, material furnace tube, reactor exit piping, high temperature heat exchanger, low temperature heat exchanger, and pressure reducing valve), 2. Questionnaire concerning maintenance of indirect desulfurization (reactor, high temperature separation tank, material furnace tube, reactor exit piping, high temperature heat exchanger, low temperature heat exchanger, and pressure reducing valve), 3. Questionnaire concerning maintenance of fluidized catalytic cracker (reactor, regeneration tower, riser pipe, and fractionator bottom pump). The questionnaire this time was distributed to 27 domestic oil companies, with the reply received from 23 of them. The replies were summarized by each type of equipment. Shown at the back of the report were the cases of damage and handling in FCC's and reactors. (NEDO)

  11. Seasonal Dynamics of River Corridor Exchange Across the Continental United States

    Science.gov (United States)

    Gomez-Velez, J. D.; Harvey, J. W.; Scott, D.; Boyer, E. W.; Schmadel, N. M.

    2017-12-01

    River corridors store and convey mass and energy from landscapes to the ocean, altering water quality and ecosystem functioning at the local, reach, and watershed scales. As water moves through river corridors from headwaters streams to coastal estuaries, dynamic exchange between the river channel and its adjacent riparian, floodplain, and hyporheic zones, combined with ponded waters such as lakes and reservoirs, results in the emergence of hot spots and moments for biogeochemical transformations. In this work, we used the model Networks with EXchange and Subsurface Storage (NEXSS) to estimate seasonal variations in river corridor exchange fluxes and residence times along the continental United States. Using a simple routing scheme, we translate these estimates into a cumulative measure of river corridor connectivity at the watershed scale, differentiating the contributions of hyporheic zones, floodplains, and ponded waters. We find that the relative role of these exchange subsystems changes seasonally, driven by the intra-seasonal variability of discharge. In addition, we find that seasonal variations in discharge and the biogeochemical potential of hyporheic zones are out of phase. This behavior results in a significant reduction in hyporheic water quality functions during high flows and emphasizes the potential importance of reconnecting floodplains for managing water quality during seasonal high flows. Physical parameterizations of river corridor processes are critical to model and predict water quality and to sustainably manage water resources under present and future socio-economic and climatic conditions. Parsimonious models like NEXSS can play a key role in the design, implementation, and evaluation of sustainable management practices that target both water quantity and quality at the scale of the nation. This research is a product of the John Wesley Powell Center River Corridor Working Group.

  12. Use of Equipment Information System (EQUIS) to determine priority for purchasing safeguards equipment

    International Nuclear Information System (INIS)

    Silberberg, S.

    1988-01-01

    To manage its large world-wide inventory of safeguards equipment, the IAEA Safeguards department uses a computerized Equipment Information System (EQUIS). EQUIS data have been analyzed using Queueing Theory to determine if inventory is adequate to meet inspector demands and in those cases where it is inadequate, to indicate how many additional units should be procured. Results are tabulated for various types of non-destructive analysis (NDA) equipment. For equipment where there is a high turnover and hence a large amount of data, the analysis provides a powerful tool for assisting procurement decisions

  13. Implementation of remote equipment at TMI-2 [Three Mile Island Unit 2

    International Nuclear Information System (INIS)

    Giefer, D.; Jeffries, A.B.

    1988-01-01

    Each of the remote vehicles in use, or planned for use, at Three Mile Island Unit 2 (TMI-2) during the period from 1984 to the present had certain distinct common features. These were proven to be desirable for remote application in the TMI-2 environment. Proper implementation requires consideration of the following: control systems, rigging systems, power supplies, operator/support interface, maintenance concerns, viewing systems, contamination control, and communications. Design and component fabrication of these features allowed deployment of each of the remote devices. This paper discusses these systems and their impact for the use of remote mobile equipment at TMI-2. In most cases, the means of implementation dictated the design features of the devices

  14. Eddy current automatic inspection of heat exchangers in nuclear power stations

    International Nuclear Information System (INIS)

    Cazal, M.; Scopelliti, J.D.; Mendez, J.

    1997-01-01

    This presentation describes the eddy current tube inspection techniques for heavy heat exchangers in nuclear power stations. The purpose of these eddy current tests, is first to determine the integrity of the heat exchanger tubes, and to characterize the related types of defects in each case following to their analysis and cause determination and subsequent inspection planning. This task requires a group highly qualified personnel with high tech automate equipment. The organization of the group required a correct function and task assignment in order to achieve efficiency in scheduling, with simultaneous inspection to different components in a continuous base and uninterruptedly. A lead specialist is in charge of the group, which is set up by several shift supervisors, a qualified tele manipulator installation crew a number of qualified tele manipulator operators, and the specialist for data acquisition and certified eddy current signal evaluators plus some other support technicians and administrations helpers. In order to comply with inspection requirements, a bunch of technical procedures had to be developed. The following equipment is available nowadays: Zetec SM-13, SM-23 and SM-22 tele manipulators for inspection probes positioning, with different shapes and configuration (rotating probes, flexible probes for U-Bends, and magnetic saturation probes endowed with their own driving units) and remote data acquisition units identified as MIZ-18 A and MIZ-30, which are remotely operated from a mobile lab installed in a trailer, outside the reactor building. The available equipment allows a simultaneous inspection of three different plant components (two steam generators and a moderator heat exchanger). We are also in a position of performing eddy current tube inspection in more than a NSP at the same time. The Zetec Eddynet software is used in the manipulator operation and for the data acquisition and defect evaluation. This software operates within Windows

  15. 40 CFR 1054.626 - What special provisions apply to equipment imported under the Transition Program for Equipment...

    Science.gov (United States)

    2010-07-01

    ... EMISSIONS FROM NEW, SMALL NONROAD SPARK-IGNITION ENGINES AND EQUIPMENT Special Compliance Provisions § 1054... provisions of this section and send us an annual report, as follows: (1) Notify the Designated Compliance... and manufacturing equipment. Companies that import equipment into the United States without meeting...

  16. Market Assessment for Residential Refrigerator-Freezer with Novel Rotating Heat Exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Sikes, Karen [CSRA International, Inc., Fairfax, VA (United States); Blackburn, Julia [CSRA International, Inc., Fairfax, VA (United States); Grubbs, Tyler [CSRA International, Inc., Fairfax, VA (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Momen, Ayyoub [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-02-01

    Despite a steady record of energy efficiency improvements in residential refrigerators and freezers over recent decades, these products still account for 4% of the site energy consumption for the average U.S. household. The Oak Ridge National Laboratory (ORNL) – along with partners Sandia National Laboratories (SNL) and the University of Maryland – are pursuing further efficiency improvements in this market sector by using a novel/prototype rotating heat exchanger (RHX) based on a Sandia Cooler technology as an evaporator in a residential refrigerator-freezer. The purpose of this study is to investigate the market potential of refrigerator-freezer products equipped with RHX evaporators in the United States, including projections of maximum annual market share and unit shipments and maximum direct and indirect job creation.

  17. X-ray equipment

    International Nuclear Information System (INIS)

    Redmayne, I.G.B.

    1988-01-01

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.)

  18. X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Redmayne, I.G.B.

    1988-01-06

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.).

  19. Qualification of electrical equipment. A United States nuclear system supplier perspective

    International Nuclear Information System (INIS)

    Jordan, W.G.

    1978-01-01

    At Westinghouse Pressurized Water Reactor Systems Division (PWR-SD) qualification. of safety related electrical equipment can be segregated into three distinct generations: (1) the initial seismic and environmental qualification programs for electrical equipment (1969-1972); (2) the supplemental sismic and environmental qualification programs (1975-1977); and (3) the seismic and environmental qualification programs to meet IEEE-323-1974, IEEE Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations''(1975). The latter two programs (in a licensing framework), as they are most current, with emphasis on electrical equipment (e.g. transmitters, rack mounted equipment) as opposed to electro-mechanical equipment (valve operators, pump motors) are reviewed. (author)

  20. A systematic approach applied in design of a micro heat exchanger

    DEFF Research Database (Denmark)

    Omidvarnia, Farzaneh; Hansen, Hans Nørgaard; Sarhadi, Ali

    2016-01-01

    The number of products benefiting from micro components in the market is increasing, and consequently, the demand for well-matched tools, equipment and systems with micro features is eventually increasing as well. During the design process of micro products, a number of issues appear which...... from the design process of the micro heat exchanger are added to the RTC unit and can be applied as guidelines in design pro- cess of any other micro heat exchanger. In other words, the current study can provide a useful guideline in design for manufacturing of micro products....... are inherent due to the down scaling or physical phenomena dominating in the micro range but negligible in the macro scale. In fact, some aspects in design for micro manufacturing are considerably different compared to the de- sign procedure taken at the macro level. Identifying the differences between design...

  1. Industrial Technology Modernization Program. Project 44. Modernize Facility Equipment and Processes. Volume 2. Revision 2. Phase 2

    Science.gov (United States)

    1988-05-01

    not be implemented. A change in foreign exchange rates (which increase the equipment cost) and a reduction in marketing forecast resulted in an...project will not be implemented due to unfavorable changes in foreign exchange rates (which increase the equipment costs) and a reduction in market

  2. Electronic equipment for spectrometric data processing

    International Nuclear Information System (INIS)

    Antonov, L.J.; Trenev, A.M.; Todorova, E.I.; Dimitrov, V.D.

    1978-01-01

    Electronic equipment carrying out logical operations and a full set of the arithmetic operations was developed for spectrometric data processing. The flowsheet of the computing part of the device, made on the basis of a specialized integral circuit, is given. The device includes input registers, multiplexor, matrix commutator, arithmetic unit and indication unit. The equipment is rated to carry out calculations according to comparatively complex formulae in several seconds

  3. A Bootstrap Neural Network Based Heterogeneous Panel Unit Root Test: Application to Exchange Rates

    OpenAIRE

    Christian de Peretti; Carole Siani; Mario Cerrato

    2010-01-01

    This paper proposes a bootstrap artificial neural network based panel unit root test in a dynamic heterogeneous panel context. An application to a panel of bilateral real exchange rate series with the US Dollar from the 20 major OECD countries is provided to investigate the Purchase Power Parity (PPP). The combination of neural network and bootstrapping significantly changes the findings of the economic study in favour of PPP.

  4. Diagnostic imaging and radiation therapy equipment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-05-01

    This is the third edition of CSA Standard C22.2 No. 114 (now CAN/CSA-C22.2 No. 114), which is one of a series of standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. This edition marks an important shift towards harmonization of Canadian requirements with those of the European community and the United States. Also important to this edition is the expansion of its scope to include the complete range of diagnostic imaging and radiation therapy equipment, rather than solely radiation-emitting equipment. In so doing, equipment previously addressed by CSA Standard C22.2 No. 125, Electromedical Equipment, specifically lasers for medical applications and diagnostic ultrasound units, is now dealt with in the new edition. By virtue of this expanded scope, many of the technical requirements in the electromedical equipment standard have been introduced to the new edition, thereby bringing CSA Standard C22.2 No. 114 up to date. 14 tabs., 16 figs.

  5. Diagnostic imaging and radiation therapy equipment

    International Nuclear Information System (INIS)

    1990-05-01

    This is the third edition of CSA Standard C22.2 No. 114 (now CAN/CSA-C22.2 No. 114), which is one of a series of standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. This edition marks an important shift towards harmonization of Canadian requirements with those of the European community and the United States. Also important to this edition is the expansion of its scope to include the complete range of diagnostic imaging and radiation therapy equipment, rather than solely radiation-emitting equipment. In so doing, equipment previously addressed by CSA Standard C22.2 No. 125, Electromedical Equipment, specifically lasers for medical applications and diagnostic ultrasound units, is now dealt with in the new edition. By virtue of this expanded scope, many of the technical requirements in the electromedical equipment standard have been introduced to the new edition, thereby bringing CSA Standard C22.2 No. 114 up to date. 14 tabs., 16 figs

  6. Road Safety Peer Exchange for Tribal Governments : an RSPCB Peer Exchange

    Science.gov (United States)

    2014-12-01

    This report provides a summary of the proceedings of the Road Safety Peer Exchange for Tribal : Governments held in Albuquerque, New Mexico on December 9th and 10th, 2014. The peer exchange : brought together safety practitioners from across the Unit...

  7. Free-world microelectronic manufacturing equipment

    Science.gov (United States)

    Kilby, J. S.; Arnold, W. H.; Booth, W. T.; Cunningham, J. A.; Hutcheson, J. D.; Owen, R. W.; Runyan, W. R.; McKenney, Barbara L.; McGrain, Moira; Taub, Renee G.

    1988-12-01

    Equipment is examined and evaluated for the manufacture of microelectronic integrated circuit devices and sources for that equipment within the Free World. Equipment suitable for the following are examined: single-crystal silicon slice manufacturing and processing; required lithographic processes; wafer processing; device packaging; and test of digital integrated circuits. Availability of the equipment is also discussed, now and in the near future. Very adequate equipment for most stages of the integrated circuit manufacturing process is available from several sources, in different countries, although the best and most widely used versions of most manufacturing equipment are made in the United States or Japan. There is also an active market in used equipment, suitable for manufacture of capable integrated circuits with performance somewhat short of the present state of the art.

  8. Field tests for the comparative evaluation of heat and enthalpy exchangers in compact ventilation units; Feldvergleich von Waerme- und Enthalpieuebertragern in Kompakt-Lueftungsgeraeten - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Frei, B.

    2007-07-01

    In an efficiency review on low energy buildings promoted by the Swiss Federal Office of Energy, low air humidity has been measured during thousands of annual hours. Modern compact ventilation units are being increasingly offered with transmission of heat and moisture. One possibility to raise the air humidity level is an enthalpy exchanger with steam-permeable membranes. With an enthalpy exchanger you can not only recover heat but also a good part of the humidity of the return air. In a comparative field study alternate applications with enthalpy or heat exchangers have been analysed at four different locations. Also calculations have been made to estimate how a rotating heat exchanger with ion-exchange resin would have performed. The comparative field study has shown that the enthalpy exchanger is able to raise the humidity level. Conditions for this are internal humidity loads, balanced air volume rates which correspond to occupancy as well as low leakages of the ventilation unit. Over-moistening due to the system with enthalpy exchanger was not found. The measurements have been affected by a sequence of winter months which have been partially warmer than usual. Otherwise the difference between enthalpy and heat exchangers would have been more significant. (author)

  9. Methods for improvement of some parameters of medical X-ray diagnostic equipment. Basic faults in selection of appropriate new or used units

    International Nuclear Information System (INIS)

    Tonev, M.; Danev, N.; Constantinov, B.

    2004-01-01

    An analysis is made of the factors determining the quality and performance of the main types of medical equipment: conventional radiographic and fluoroscopic X-ray unit; X-ray computer tomograph (CT); angiographic, mammographic, densitometric and dental X-ray equipment; magnetic resonance MRI. The aim is to give certain directions for the method one should adopt on choosing and purchasing X-ray equipment. Also one should take into consideration the new Health law and the Regulation for radiation protection of persons undergoing medical examination or treatment. The problems can be solved with the close cooperation between radiologists, medical physicists and x-ray engineers

  10. Innovative heat exchangers

    CERN Document Server

    Scholl, Stephan

    2018-01-01

    This accessible book presents unconventional technologies in heat exchanger design that have the capacity to provide solutions to major concerns within the process and power-generating industries. Demonstrating the advantages and limits of these innovative heat exchangers, it also discusses micro- and nanostructure surfaces and micro-scale equipment, and introduces pillow-plate, helical and expanded metal baffle concepts. It offers step-by-step worked examples, which provide instructions for developing an initial configuration and are supported by clear, detailed drawings and pictures. Various types of heat exchangers are available, and they are widely used in all fields of industry for cooling or heating purposes, including in combustion engines. The market in 2012 was estimated to be U$ 42.7 billion and the global demand for heat exchangers is experiencing an annual growth of about 7.8 %. The market value is expected to reach U$ 57.9 billion in 2016, and approach U$ 78.16 billion in 2020. Providing a valua...

  11. Impulse Response of the Exchange Rate Volatility to a Foreign Exchange Intervention Shock

    OpenAIRE

    Hoshikawa, Takeshi

    2009-01-01

    This paper uses Lin's technique (1997) to report on the impulse response function analysis that traces the dynamics of exchange rate volatility from innovations in Japanese foreign exchange intervention. Using a multivariate GARCH model, we employed a volatility impulse response function based on Lin (1997) to detect the impulse response of exchange rate volatility on a one-unit foreign exchange intervention shock. The main findings of t his paper are as follows: (1) a foreign exchange inter...

  12. Exchange sex among people receiving medical care for HIV in the United States - medical monitoring project 2009-2013.

    Science.gov (United States)

    Olaiya, Oluwatosin; Nerlander, Lina; Mattson, Christine L; Beer, Linda

    2018-04-20

    Many studies of persons who exchange sex for money or drugs have focused on their HIV acquisition risk, and are often limited to select populations and/or geographical locations. National estimates of exchange sex among people living with HIV (PLWH) who are in medical care, and its correlates, are lacking. To address these gaps, we analyzed data from the Medical Monitoring Project, a surveillance system that produces nationally representative estimates of behavioral and clinical characteristics of PLWH receiving medical care in the United States, to estimate the weighted prevalence of exchange sex overall, and by selected socio-demographic, behavioral and clinical characteristics. We found 3.6% of sexually active adults reported exchange sex in the past 12 months. We found a higher prevalence of exchange sex among transgender persons, those who experienced homelessness, and those with unmet needs for social and medical services. Persons who exchanged sex were more likely to report depression and substance use than those who did not exchange sex. We found a higher prevalence of sexual behaviors that increase the risk of HIV transmission and lower viral suppression among persons who exchanged sex. PLWH who exchanged sex had a higher prevalence of not being prescribed ART, and not being ART adherent than those who did not exchange sex. We identify several areas for intervention, including: provision of or referral to services for unmet needs (such as housing or shelter), enhanced delivery of mental health and substance abuse screening and treatment, risk-reduction counseling, and ART prescription and adherence support services.

  13. Development of a method for calculating steady-state equipment sensible heat ratio of direct expansion air conditioning units

    International Nuclear Information System (INIS)

    Xia Liang; Chan, M.Y.; Deng Shiming

    2008-01-01

    A complete set of calculation method for steady-state equipment sensible heat ratio (SHR) for a direct expansion (DX) cooling coil has been developed and reported. The method was based on the fundamentals of energy conservation and heat and mass transfer taking place in the DX cooling coil, and was experimentally validated using an experimental DX A/C rig. With the method developed, the effect of refrigerant evaporating temperature at fixed inlet air conditions on equipment SHR has been theoretically analyzed. The validated method can be useful in further studying the inherent operating characteristics of a DX air conditioning (A/C) unit and in developing suitable control strategies for achieving higher energy efficiency and better indoor thermal environment

  14. The performance investigation of a temperature cascaded cogeneration system equipped with adsorption desalination unit

    KAUST Repository

    Myat, Aung

    2013-02-01

    This paper presents the performance investigation of a temperature cascaded cogeneration plant, shortly in TCCP, equipped with an efficient waste heat recovery system. The TCCP or cogeneration system produces four types of useful energy namely (i) electricity, (ii) steam, (iii) cooling, and (iv) dehumidification and distilled water by utilizing single energy source. The TCCP comprises a Capstone C30 micro-turbine that generates nominal capacity of 26 kW of electricity, a compact and efficient waste heat recovery system and a host of waste heatactivated devices namely (i) a steam generator, (ii) an absorption chiller, (iii) an adsorption desalination system, and (iv) a multi-bed desiccant dehumidifier. The analysis is performed under different operation conditions such as heat source temperatures, flow rates of heat transfer fluids and chilled water inlet temperatures. The only single heat source for TCCP is obtained from exhaust gas of micro-turbine and it is channeled to a series of waste heat recovery heat exchangers to steam and hot water at different temperatures. Hot water produced by such a compact heat exchangers is the driving heat source to produce steam of 15 kg/h, cooling of 2 Rton, dehumidification of 2 Rton, and distilled water of 0.7 m3/day. A set of experiments, both part load and full load, of micro-turbine is conducted to examine the electricity generation and the exhaust gas temperature. It is observed that energy utilization factor could achieve as high as 70% while fuel energy saving ratio is found to be 28%. © 2013 Desalination Publications. All rights reserved.

  15. The performance investigation of a temperature cascaded cogeneration system equipped with adsorption desalination unit

    KAUST Repository

    Myat, Aung; Thu, Kyaw; Kim, Youngdeuk; Ng, K. C.

    2013-01-01

    This paper presents the performance investigation of a temperature cascaded cogeneration plant, shortly in TCCP, equipped with an efficient waste heat recovery system. The TCCP or cogeneration system produces four types of useful energy namely (i) electricity, (ii) steam, (iii) cooling, and (iv) dehumidification and distilled water by utilizing single energy source. The TCCP comprises a Capstone C30 micro-turbine that generates nominal capacity of 26 kW of electricity, a compact and efficient waste heat recovery system and a host of waste heatactivated devices namely (i) a steam generator, (ii) an absorption chiller, (iii) an adsorption desalination system, and (iv) a multi-bed desiccant dehumidifier. The analysis is performed under different operation conditions such as heat source temperatures, flow rates of heat transfer fluids and chilled water inlet temperatures. The only single heat source for TCCP is obtained from exhaust gas of micro-turbine and it is channeled to a series of waste heat recovery heat exchangers to steam and hot water at different temperatures. Hot water produced by such a compact heat exchangers is the driving heat source to produce steam of 15 kg/h, cooling of 2 Rton, dehumidification of 2 Rton, and distilled water of 0.7 m3/day. A set of experiments, both part load and full load, of micro-turbine is conducted to examine the electricity generation and the exhaust gas temperature. It is observed that energy utilization factor could achieve as high as 70% while fuel energy saving ratio is found to be 28%. © 2013 Desalination Publications. All rights reserved.

  16. 7 CFR 3300.64 - Application for certificate for new equipment produced or assembled in the United States or in a...

    Science.gov (United States)

    2010-01-01

    ... case of a unit of equipment (i.e., the insulated body with its mechanical refrigerating appliance... insulated body have been tested separately: (1) For the reference mechanical refrigerating appliance: (i... reference insulated body. See paragraph (3)(iii) below. (2) For the identical mechanical refrigerating...

  17. Semiautomatic exchanger of samples for carry out neutron activation analysis

    International Nuclear Information System (INIS)

    Aguilar H, F.; Quintana C, G.; Torres R, C. E.; Mejia J, J. O.

    2015-09-01

    In this paper the design methodology and implementation of a semiautomatic exchanger of samples for the Analysis Laboratory by Neutron Activation of the Reactor department is presented. Taking into account the antecedents, the necessities of improvement are described, as well as the equipment that previously contained the Laboratory. The project of the semiautomatic exchanger of samples was developed at Instituto Nacional de Investigaciones Nucleares, with its own technology to increase independence from commercial equipment. Each element of the semiautomatic exchanger of samples is described both in the design phase as construction. The achieved results are positive and encouraging for the fulfillment of the proposed objective that is to increase the capacity of the Laboratory. (Author)

  18. Experimental evaluation of vibrations in heat exchangers

    International Nuclear Information System (INIS)

    Martin Ghiselli, A.

    1997-01-01

    Flow induced vibrations may produce damage of heat exchangers, condensers and steam generators tubes. To evaluate this problem a set of tests were developed to know the real support state of the tubes, which have great influence on the vibration response. This paper include a description of the tests and the results obtained applying them on a heat exchanger equipment. (author) [es

  19. Analysis of licensed South African diagnostic imaging equipment ...

    African Journals Online (AJOL)

    Analysis of licensed South African diagnostic imaging equipment. ... Pan African Medical Journal ... Introduction: Objective: To conduct an analysis of all registered South Africa (SA) diagnostic radiology equipment, assess the number of equipment units per capita by imaging modality, and compare SA figures with published ...

  20. Fuel exchanging machine for a nuclear ship

    International Nuclear Information System (INIS)

    Hayashi, Tetsuji.

    1984-01-01

    Purpose: To prevent atmospheric contaminations upon fuel exchange thereby keep the environmental circumstance clean in the periphery of the nuclear ship. Constitution: A nuclear reactor container is disposed to the inside of a containing vessel in the ship body and a shutter is mounted to the upper opening of the ship body. Further, a landing container having a bottom opening equipped with shutter for alingning the upper opening equipped with shuuter of the ship is elevatably suspended to the trolley of a crane by way of a wire rope and a winch, and a fuel exchange cask is elevatably disposed to the inside of the landing container. Further, airs in the inside of the container is adapted to be discharged externally through a filter by means of a blower and the inside is kept at a negative pressure. Thus, since the containing vessel is covered with the landing container upon fuel exchanging operation, atmospheric contamination can be prevented sufficiently. (Sekiya, K.)

  1. Heat exchanger designed as longitudinal counter flow equipment

    International Nuclear Information System (INIS)

    Ecker, H.

    1976-01-01

    An improvement for heat exchangers is described, which should make them suitable for use in a closed gas turbine cycle or in the primary loop of a gas-cooled high-temperature reactor with a helium turbine, as they have a small volume. It is proposed that the bundles of tubes should be divided into separate boxes, which are arranged in a hexagonal grid; the return pipes are arranged in a sheath in the centre of this grid and are welded to the cover of this. The subdivision into separate boxes makes maintenance easier. Constructional details are given, and there are 9 drawings. (UWI) [de

  2. Radiation exchange factors between specular inner surfaces of a rectangular enclosure such as transplant production unit

    International Nuclear Information System (INIS)

    Abdel-Ghany, Ahmed M.; Kozai, Toyoki

    2006-01-01

    General mathematical relations are presented for the specular exchange factors, F S , of diffuse radiation exchange between the inner surfaces of a rectangular enclosure. Three of these surfaces are specular reflectors, diffuse emitters and the fourth surface is a diffuse reflector, diffuse emitter. This enclosure can be used as a transplant production unit with artificial lighting for electric energy saving purposes. An image system and the crossed string method are used to derive these relations. The resulting expressions are conceptually simple and similar to the commonly known expressions of the exchange factors between diffuse surfaces, F. The accuracy of the presented F S relations was examined for different numbers of multiple reflections, N, on the specular surfaces and for different aspect ratios (ratio of the width, w to the height, h). The results proved that the relations are accurate and strongly satisfy the well-known relation of the radiation exchange between enclosure surfaces and satisfy the reciprocity relation. For any aspect ratio, considering N of 150 between highly reflective surfaces (ρ = 0.99) is sufficient to estimate the F S factors without any possible error. Using specular reflecting surfaces in such cases significantly reduces the electric energy consumption used for lighting

  3. Diagnostic x-ray equipment and its use

    International Nuclear Information System (INIS)

    1993-01-01

    The guide contains the requirements for the use, structure and operation of diagnostic x-ray equipment necessary to ensure the radiation safety of workers and patients. The guide is intended for the party responsible for operating the x-ray units, the staff operating, installing and maintaining x-ray examination equipment, and companies manufacturing and selling such equipment. Special requirements for mammographic and dental x-ray equipments are given in separate ST guides. (5 refs., 1 figs., 2 tabs.)

  4. Empirical Analysis for the Heat Exchange Effectiveness of a Thermoelectric Liquid Cooling and Heating Unit

    Directory of Open Access Journals (Sweden)

    Hansol Lim

    2018-03-01

    Full Text Available This study aims to estimate the performance of thermoelectric module (TEM heat pump for simultaneous liquid cooling and heating and propose empirical models for predicting the heat exchange effectiveness. The experiments were conducted to investigate and collect the performance data of TEM heat pump where the working fluid was water. A total of 57 sets of experimental data were statistically analyzed to estimate the effects of each independent variable on the heat exchange effectiveness using analysis of variance (ANOVA. To develop the empirical model, the six design parameters were measured: the number of transfer units (NTU of the heat exchangers (i.e., water blocks, the inlet water temperatures and temperatures of water blocks at the cold and hot sides of the TEM. As a result, two polynomial equations predicting heat exchange effectiveness at the cold and hot sides of the TEM heat pump were derived as a function of the six selected design parameters. Also, the proposed models and theoretical model of conventional condenser and evaporator for heat exchange effectiveness were compared with the additional measurement data to validate the reliability of the proposed models. Consequently, two conclusions have been made: (1 the possibility of using the TEM heat pump for simultaneous cooling and heating was examined with the maximum temperature difference of 30 °C between cold and hot side of TEM, and (2 it is revealed that TEM heat pump has difference with the conventional evaporator and condenser from the comparison results between the proposed models and theoretical model due to the heat conduction and Joule effect in TEM.

  5. Market Potential for Residential Biomass Heating Equipment: Stochastic and Econometric Assessments

    OpenAIRE

    Adee Athiyaman

    2015-01-01

    This paper provides estimates of market potential for biomass-residential-heating equipment in the US: that is, the greatest amount of biomass-residential-heating equipment that can be sold by the industry. The author's analysis is limited to biomass equipment used most to heat the housing unit. Assuming that households equipped with 10+ year old primary heating devices will replace rather than repair the devices he predicts that approximately 1.4 million units of residential home heating equ...

  6. Developing a Logistics Data Process for Support Equipment for NASA Ground Operations

    Science.gov (United States)

    Chakrabarti, Suman

    2010-01-01

    The United States NASA Space Shuttle has long been considered an extremely capable yet relatively expensive rocket. A great part of the roughly US $500 million per launch expense was the support footprint: refurbishment and maintenance of the space shuttle system, together with the long list of resources required to support it, including personnel, tools, facilities, transport and support equipment. NASA determined to make its next rocket system with a smaller logistics footprint, and thereby more cost-effective and quicker turnaround. The logical solution was to adopt a standard Logistics Support Analysis (LSA) process based on GEIA-STD-0007 http://www.logisticsengineers.org/may09pres/GEIASTD0007DEXShortIntro.pdf which is the successor of MIL-STD-1388-2B widely used by U.S., NATO, and other world military services and industries. This approach is unprecedented at NASA: it is the first time a major program of programs, Project Constellation, is factoring logistics and supportability into design at many levels. This paper will focus on one of those levels NASA ground support equipment for the next generation of NASA rockets and on building a Logistics Support Analysis Record (LSAR) for developing and documenting a support solution and inventory of resources for. This LSAR is actually a standards-based database, containing analyses of the time and tools, personnel, facilities and support equipment required to assemble and integrate the stages and umbilicals of a rocket. This paper will cover building this database from scratch: including creating and importing a hierarchical bill of materials (BOM) from legacy data; identifying line-replaceable units (LRUs) of a given piece of equipment; analyzing reliability and maintainability of said LRUs; and therefore making an assessment back to design whether the support solution for a piece of equipment is too much work, i.e., too resource-intensive. If one must replace or inspect an LRU too much, perhaps a modification of

  7. Investigation of the Dynamic Melting Process in a Thermal Energy Storage Unit Using a Helical Coil Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Xun Yang

    2017-08-01

    Full Text Available In this study, the dynamic melting process of the phase change material (PCM in a vertical cylindrical tube-in-tank thermal energy storage (TES unit was investigated through numerical simulations and experimental measurements. To ensure good heat exchange performance, a concentric helical coil was inserted into the TES unit to pipe the heat transfer fluid (HTF. A numerical model using the computational fluid dynamics (CFD approach was developed based on the enthalpy-porosity method to simulate the unsteady melting process including temperature and liquid fraction variations. Temperature measurements using evenly spaced thermocouples were conducted, and the temperature variation at three locations inside the TES unit was recorded. The effects of the HTF inlet parameters were investigated by parametric studies with different temperatures and flow rate values. Reasonably good agreement was achieved between the numerical prediction and the temperature measurement, which confirmed the numerical simulation accuracy. The numerical results showed the significance of buoyancy effect for the dynamic melting process. The system TES performance was very sensitive to the HTF inlet temperature. By contrast, no apparent influences can be found when changing the HTF flow rates. This study provides a comprehensive solution to investigate the heat exchange process of the TES system using PCM.

  8. Auditing of Monitoring and Respiratory Support Equipment in a Level III-C Neonatal Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Elena Bergon-Sendin

    2015-01-01

    Full Text Available Background. Random safety audits (RSAs are a safety tool but have not been widely used in hospitals. Objectives. To determine the frequency of proper use of equipment safety mechanisms in relation to monitoring and mechanical ventilation by performing RSAs. The study also determined whether factors related to the patient, time period, or characteristics of the area of admission influenced how the device safety systems were used. Methods. A prospective observational study was conducted in a level III-C Neonatal Intensive Care Unit (NICU during 2012. 87 days were randomly selected. Appropriate overall use was defined when all evaluated variables were correctly programmed in the audited device. Results. A total of 383 monitor and ventilator audits were performed. The Kappa coefficient of interobserver agreement was 0.93. The rate of appropriate overall use of the monitors and respiratory support equipment was 33.68%. Significant differences were found with improved usage during weekends, OR 1.85 (1.12–3.06, p=0.01, and during the late shift (3 pm to 10 pm, OR 1.59 (1.03–2.4, p=0.03. Conclusions. Equipment safety systems of monitors and ventilators are not properly used. To improve patient safety, we should identify which alarms are really needed and where the difficulties lie for the correct alarm programming.

  9. Electron exchange reaction in anion exchangers as observed in uranium isotope separation

    International Nuclear Information System (INIS)

    Obanawa, Heiichiro; Takeda, Kunihiko; Seko, Maomi

    1991-01-01

    The mechanism of electron exchange in an ion exchanger, as occurring between U 4+ and UO 2 2+ in uranium isotope separation, was investigated. The height of the separation unit (H q ) in the presence of metal ion catalysts, as obtained from the separation experiments, was found to be almost coincident with the theoretical value of H q as calculated on the basis of the intrasolution acceleration mechanism of the metal ion, suggesting that the electron exchange mechanism in the ion-exchanger is essentially the same as that in the solution when metal ion catalysts are present. Separation experiments with no metal ion catalyst, on the other hand, showed the electron exchange reaction in the ion exchanger to be substantially higher than that in the solution, suggesting an acceleration of the electron exchange reaction by the ion-exchanger which is due to the close existence of higher order Cl - complexes of UO 2 2+ and U 4+ in the vicinity of the ion-exchange group. (author)

  10. Automatic dose-rate controlling equipment

    International Nuclear Information System (INIS)

    Szasz, T.; Nagy Czirok, Cs.; Batki, L.; Antal, S.

    1977-01-01

    The patent of a dose-rate controlling equipment that can be attached to X-ray image-amplifiers is presented. In the new equipment the current of the photocatode of the image-amplifier is led into the regulating unit, which controls the X-ray generator automatically. The advantages of the equipment are the following: it can be simply attached to any type of X-ray image-amplifier, it accomplishes fast and sensitive regulation, it makes possible the control of both the mA and the kV values, it is attached to the most reliable point of the image-transmission chain. (L.E.)

  11. Mathematical model for optimization of multilayer submerged-arc welding of frame equipment of power units

    International Nuclear Information System (INIS)

    Pankov, V.V.; Chernyshev, G.G.; Kozlov, N.E.

    1987-01-01

    A mathematical model for optimization of multilayer submerged arc welding of frame equipment of power units is constructed. The variation-energy method permits to construct the universal mathematical model for strengthening formation of a single bead; the method is reasonable for simulation of a multilayer welded joint. Minimization of the distance between maximum and minimum layer height of a built-up metal is the necessary condition for qualitative formation of the multilayer joint. One can calculate in real time scale the optimal vector of maximally ten parameters under the multilayer welding condition immediately after change in the grooving width using the developed mathematical model of optimization

  12. Exchange of equipment between CERN and JINR

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    The drift chambers of the former NA48 experiment have recently left CERN to be installed in the MPD experiment at the future NICA accelerator in Dubna, Russia. As a counterpart, the JINR Laboratory will produce drift chambers for the new NA62 experiment. This operation is a fruitful exchange of technology that profits both laboratories and enhances their collaboration.   On 22 July, in the occasion of the departure of the chambers from CERN, Mikhail Itkis (centre), acting Director of the JIINR visited the NA62 experimental area accompanied by Rolf Heuer (left), CERN Director General and Ferdinand Hahn, NA62 technical Co-ordinator. The NA48 drift chambers were overhauled in 2000 and employed until 2008. With a total of 110 kilometres of wire soldered to a very high degree of precision, the four drift chambers were a crucial element of the experimental kaon programme at CERN. The chambers are now moving to a new challenge as they will be re-used by the Multi Purpose Detector (MPD) experiment, under...

  13. Research of the heat exchanging processes running in the heating and hot water supply loops of the coil heat exchangers

    Directory of Open Access Journals (Sweden)

    Ірина Геннадіївна Шитікова

    2016-11-01

    Full Text Available The fuel-energy complex research has made it possible to disclose a huge power-saving potential in the municipal heat-and-power engineering. Power-and-resource-saving units and systems are becoming extremely urgent because of the power engineering crisis expansion. The self-adjusting heat supply system from the individual heating points with the heat-accumulating units and coil heat exchangers for independent heating and water supply systems has been examined. Coil heat exchangers are used in municipal heating for heat transfer (e.g. geothermal waters for the independent mains of the heating and hot water supply systems. The heat engineering calculation of the heating and accumulating unit with the coil heat exchanger for independent heat supply systems from individual heater was performed and experimental data were received at the experimental industrial unit under the laboratory conditions. The peculiarities of the flows in the intertubular space, their influence on the heat exchange and temperatures of the first and intermediate mains have been shown. It is important to know the processes running inside the apparatus to be able to improve the technical characteristics of the three-loop coil heat exchanger. The task solution will make it possible to save the materials consumption for the three-loop coil heat exchangers in the future

  14. Heat exchanger. [Nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Molina, C; Brisseaux, A

    1976-01-19

    This invention concerns a heat exchanger between a fluid flowing through a tube and a gas. Such an exchanger can be used, inter alia, for removing calories that cannot be used for generating electricity in a thermal or nuclear power station. This exchanger can withstand any pressure surges in the system and even the use of a high vapour pressure coolant such as ammonia, since the fluid flows in a round tube with low pressure drops (both with respect to the fluid to be cooled and the cooling air). It is rigid enough to stand up to being moved and handled as well as to gusts of wind. It is formed of units that can be handled without difficulty and that are easily dismantable and interchangeable, even in service, and it is easily maintained. The exchange area is high for a minimum frontal area and this enables the size of the supporting frame to be reduced and makes it easy to hide it behind a screen of trees should this prove necessary. Finally, it is composed of a small number of standard units thus reducing the industrial production cost. These units are rectangular plates, each one being a flat tubular coil fitted between two flat parallel sheet metal plates having on their outer sides flat top raised bosses. These units are assembled together by the tops of the bosses so as to form an exchanger bank, each bank comprising two collectors to which the bank coils are tightly connected.

  15. 47 CFR 2.925 - Identification of equipment.

    Science.gov (United States)

    2010-10-01

    ... common enclosure, but constructed on separate sub-units or circuit boards with independent frequency... grant of equipment authorization. (e) A software defined radio may be equipped with a means such as a... implanted within the body of a test animal or person would probably require an alternate method of...

  16. Using ADA Tasks to Simulate Operating Equipment

    Science.gov (United States)

    DeAcetis, Louis A.; Schmidt, Oron; Krishen, Kumar

    1990-01-01

    A method of simulating equipment using ADA tasks is discussed. Individual units of equipment are coded as concurrently running tasks that monitor and respond to input signals. This technique has been used in a simulation of the space-to-ground Communications and Tracking subsystem of Space Station Freedom.

  17. Computational model and performance optimization methodology of a compact design heat exchanger used as an IHX in HTGR

    International Nuclear Information System (INIS)

    De la Torre V, R.; Francois L, J. L.

    2017-09-01

    The intermediate heat exchangers (IHX) present in high-temperature gas-cooled reactor (HTGR) present complex operating conditions, characterized by temperature values higher than 1073 K. Conventional designs of tubes and shell have shown disadvantages with respect to compact designs. In this work, computational models of a compact heat exchanger design, the printed circuit, were built under IHX conditions in a HTGR installation. In these models, a detailed geometry was considered in three dimensions, corresponding to a transfer unit of the heat exchanger. Computational fluid dynamics techniques and finite element methods were used to study the thermo-hydraulic and mechanical functioning of the equipment, respectively. The properties of the materials were defined as temperature functions. The thermo-hydraulic results obtained were established as operating conditions in the structural calculations. A methodology was developed based on the analysis of capital and operating costs, which takes into account the heat transfer, pressure drop and the mechanical behavior of the structure, in a single optimization variable. By analyzing the experimental results of other authors, a relationship was obtained between the operation time of the equipment and the maximum effort in the structure, which was used in the model. The results show that the model that allows a greater thermal efficiency differs from the one that has lower total cost per year. (Author)

  18. The UK market for gaseous emissions control equipment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-09-01

    The report analyses the changes in demand for gaseous emissions control equipment in the United Kingdom over the next 5 years. It discusses the factors affecting demand such as legislation reporting of environmental performance, and economic factors. It looks at environmental expenditure by UK industry. Markets are examined, for VOC abatement systems; thermal incinerators; adsorption equipment; catalytic oxidisers; absorption equipment; biological treatments; cryogenic equipment; SO{sub x} abatement equipment; wet FGD; wet dry FGD, dry scrubbers; NOx abatement systems; selective catalytic reduction; and selective non-catalytic reduction. Profiles are given of 16 leading suppliers.

  19. Design and simulation of heat exchangers using Aspen HYSYS, and Aspen exchanger design and rating for paddy drying application

    Science.gov (United States)

    Janaun, J.; Kamin, N. H.; Wong, K. H.; Tham, H. J.; Kong, V. V.; Farajpourlar, M.

    2016-06-01

    Air heating unit is one of the most important parts in paddy drying to ensure the efficiency of a drying process. In addition, an optimized air heating unit does not only promise a good paddy quality, but also save more for the operating cost. This study determined the suitable and best specifications heating unit to heat air for paddy drying in the LAMB dryer. In this study, Aspen HYSYS v7.3 was used to obtain the minimum flow rate of hot water needed. The resulting data obtained from Aspen HYSYS v7.3 were used in Aspen Exchanger Design and Rating (EDR) to generate heat exchanger design and costs. The designs include shell and tubes and plate heat exchanger. The heat exchanger was designed in order to produce various drying temperatures of 40, 50, 60 and 70°C of air with different flow rate, 300, 2500 and 5000 LPM. The optimum condition for the heat exchanger were found to be plate heat exchanger with 0.6 mm plate thickness, 198.75 mm plate width, 554.8 mm plate length and 11 numbers of plates operating at 5000 LPM air flow rate.

  20. Proceedings of the European Symposium on Pressure Equipment - ESOPE 2007

    International Nuclear Information System (INIS)

    2007-01-01

    Every three years, and since thirty years, the AFIAP organizes a symposium where the experts and actors working in the field of pressure equipments, whether fixed or transportable, can meet and exchange on all developments related to their activity. What was at first called the 'National Congress on the technology of pressure components', and later the 'Study Days on pressure components', became since 2001 the 'European Symposium on Pressure Equipment' (ESOPE), so marking an opening to the European and International fields in a context marked by the application of the European Directives applicable to these equipments. The 2001 symposium was more particularly dedicated to the application of the directives harmonizing the construction of equipments, and the 2004 symposium was more particularly centred on the management of equipments in operation. For the ESOPE 2007 Symposium, the organizing committee wished to resume these two subjects under the aspects of the safety, the competitiveness, as well as the innovation. The plenary session of the last day will be completely dedicated to these subjects and will include a Panel discussion, where National and European authorities, representatives of manufacturers and users, as well as experts engaged in developments and new projects will express their views. These exchanges will also permit to answer the questions expressed by the participants. Every symposium has thus a main orientation, but shall also be the place of exchanges on the different subjects wished by the profession. The traditional technical sessions are consequently maintained: - Sessions on Design and Materials, - Sessions on Fabrication, - Sessions on Fitness for Service, and a special session dedicated to the National, European and International Codes is added, the afternoon of the first day. The plenary Opening session is also devoted to this last subject with lectures on the evolutions of European regulations, the orientations retained for pressure

  1. Improving nuclear safety of VVER-440 units

    International Nuclear Information System (INIS)

    Nochev, T.; Sabinov, S.

    2001-01-01

    In this paper authors deals with improvement of nuclear safety of WWER-440 units in Kozloduy NPP. Main directions for improving nuclear safety of WWER-440 units were: - to expand number of the design accident; - to increase reliability of equipment important for the safety; - to decrease the probability of initiating events; - improvements the integrity of the primary circuit (application LBB concept, qualification of the pressure safety valves to avoid pressurized thermal shock); - improvement of the fire protection; - improvement of the operation including upgrading and improvement of operational documents, implementation of new system for training the operators and etc.; - reassessment of the seismic response of the plant. Main actions were made at NPP Kozloduy to increase nuclear safety of VVER-440 units. 1. Modernization of Emergency High Pressure Safety Injection System. The modernization includes dividing of independent channels with reservation of active elements. Pumps were exchanged with more effective and reliable ones. HPSIS was increased reliability in general through decrease number of active elements and exchanged with passive. 2. For the purpose of avoiding fast cooling at the primary circuit and obtaining thermal shock of reactor vessel, Main Safety Insulation Valves are installed at NPP Kozloduy. 3. Modernization of Emergency power supplies AC. Oil breakers VMP-10 are exchanged with gas FS-4. 4. Generator breakers are installed to decrease probability of loss power supply and blackout. They provide reliable power supply to the system important for the safety in case of failure on generator. 5. I and C system has been qualified and optimized. 6. Reassessments of Limiting Conditions of Operation and new scram signals have been introduced. 7. An operators-oriented Informational System has been developed. It includes ensuring and updating of equipment data, new informational support of operator and etc. 8. A new auxiliary independent system for

  2. Evaluation of artillery equipment maintenance support capability based on grey clustering

    Science.gov (United States)

    Zhai, Mei-jie; Gao, Peng

    2017-12-01

    This paper, the theory and method of evaluating the capability of equipment maintenance support in China and abroad are studied, from the point of view of the combat task of artillery troops and the strategic attachment in the future military struggle. This paper establishes the framework of the evaluation Index system of the equipment maintenance support capability of the artillery units, and applies the grey clustering method to the evaluation of the equipment maintenance support capability of the artillery units, and finally evaluates the equipment maintenance and support capability of the artillery brigade as an example, and analyzes the evaluation results. This paper finds out the outstanding problems existing in the maintenance and support of military equipment, and puts forward some constructive suggestions, in order to improve the status of military equipment maintenance and support and improve the level of future equipment maintenance.

  3. Exchanging and Storing Energy. Reducing Energy Demand through Heat Exchange between Functions and Temporary Storage

    Energy Technology Data Exchange (ETDEWEB)

    Sillem, E.

    2011-06-15

    As typical office buildings from the nineties have large heating and cooling installations to provide heat or cold wherever and whenever needed, more recent office buildings have almost no demand for heating due to high internal heat loads caused by people, lighting and office appliances and because of the great thermal qualities of the contemporary building envelope. However, these buildings still have vast cooling units to cool down servers and other energy consuming installations. At the same time other functions such as dwellings, swimming pools, sporting facilities, archives and museums still need to be heated most of the year. In the current building market there is an increasing demand for mixed-use buildings or so called hybrid buildings. The Science Business Centre is no different and houses a conference centre, offices, a museum, archives, an exhibition space and a restaurant. From the initial program brief it seemed that the building will simultaneously house functions that need cooling most of the year and functions that will need to be heated the majority of the year. Can this building be equipped with a 'micro heating and cooling network' and where necessary temporarily store energy? With this idea a research proposal was formulated. How can the demand for heating and cooling of the Science Business Centre be reduced by using energy exchange between different kinds of functions and by temporarily storing energy? In conclusion the research led to: four optimized installation concepts; short term energy storage in pavilion concept and museum; energy exchange between the restaurant and archives; energy exchange between the server space and the offices; the majority of heat and cold will be extracted from the soil (long term energy storage); the access heat will be generated by the energy roof; PV cells from the energy roof power all climate installations; a total energy plan for the Science Business Centre; a systematic approach for exchanging

  4. TiO2/water Nanofluid Heat Transfer in Heat Exchanger Equipped with Double Twisted-Tape Inserts

    Science.gov (United States)

    Eiamsa-ard, S.; Ketrain, R.; Chuwattanakul, V.

    2018-05-01

    Nowadays, heat transfer enhancement plays an important role in improving efficiency of heat transfer and thermal systems for numerous areas such as heat recovery processes, chemical reactors, air-conditioning/refrigeration system, food engineering, solar air/water heater, cooling of high power electronics etc. The present work presents the experimental results of the heat transfer enhancement of TiO2/water nanofluid in a heat exchanger tube fitted with double twisted tapes. The study covered twist ratios of twisted tapes (y/w) of 1.5, 2.0, and 2.5) while the concentration of the nanofluid was kept constant at 0.05% by volume. Observations show that heat transfer, friction loss and thermal performance increase as twist ratio (y/w) decreases. The use of the nanofluid in the tube equipped with the double twisted-tapes with the smallest twist ratio (y/w = 1.5) results in the increases of heat transfer rates and friction factor up to 224.8% and 8.98 times, respectively as compared to those of water. In addition, the experimental results performed that double twisted tapes induced dual swirling-flows which played an important role in improving fluid mixing and heat transfer enhancement. It is also observed that the TiO2/water nanofluid was responsible for low pressure loss behaviors.

  5. Optimal design of compact organic Rankine cycle units for domestic solar applications

    Directory of Open Access Journals (Sweden)

    Barbazza Luca

    2014-01-01

    Full Text Available Organic Rankine cycle turbogenerators are a promising technology to transform the solar radiation harvested by solar collectors into electric power. The present work aims at sizing a small-scale organic Rankine cycle unit by tailoring its design for domestic solar applications. Stringent design criteria, i. e., compactness, high performance and safe operation, are targeted by adopting a multi-objective optimization approach modeled with the genetic algorithm. Design-point thermodynamic variables, e. g., evaporating pressure, the working fluid, minimum allowable temperature differences, and the equipment geometry, are the decision variables. Flat plate heat exchangers with herringbone corrugations are selected as heat transfer equipment for the preheater, the evaporator and the condenser. The results unveil the hyperbolic trend binding the net power output to the heat exchanger compactness. Findings also suggest that the evaporator and condenser minimum allowable temperature differences have the largest impact on the system volume and on the cycle performances. Among the fluids considered, the results indicate that R1234yf and R1234ze are the best working fluid candidates. Using flat plate solar collectors (hot water temperature equal to 75 °C, R1234yf is the optimal solution. The heat exchanger volume ranges between 6.0 and 23.0 dm3, whereas the thermal efficiency is around 4.5%. R1234ze is the best working fluid employing parabolic solar collectors (hot water temperature equal to 120 °C. In such case the thermal efficiency is around 6.9%, and the heat exchanger volume varies from 6.0 to 18.0 dm3.

  6. Grounds Maintenance Equipment and Procedures. Building Maintenance. Module VI. Instructor's Guide.

    Science.gov (United States)

    Crank, Virgil

    This curriculum guide, one of six modules keyed to the building maintenance competency profile developed by industry and education professionals, provides materials for two units on grounds maintenance equipment and procedures. The first unit deals with grounds maintenance equipment and includes the following lessons: safety; changing oil/filter…

  7. On-site equipment and materials against CBRNE terrorism

    International Nuclear Information System (INIS)

    Yamamoto, Soichiro; Tokita, Kenichi

    2016-01-01

    There is no almighty field service equipment that can handle by itself all CBRNE (Chemical, Biological, Radiological, Nuclear, Explosive) terrorism. Since there is merit and demerit for each of equipment, operation methods and linkage of material/equipment based on detection principle are indispensable. This paper explained the principle and operation method of detection equipment, operation using multiple material/equipment, and system construction to facilitate cooperation with related ministries and agencies. There are six examples as typical material/equipment and detection principle for handling CBRNE as shown below: (1) ion mobility spectrometer, (2) infrared spectroscopy, (3) Raman scattering spectroscopy, (4) gas chromatographic mass spectrometry, (5) fluorescent reactive dye classification method, and (6) antigen antibody reaction method. This paper shows a flowchart that can measure within the duration of a respirator while wearing Level A protective clothing (about 15 to 20 min) by the combination of detector/analyzer based on these methods. The authors developed an information system that allows prompt information exchange between the on-site administrative agencies, research institutes, and other related organizations via network, in the case when substances etc. could not be specified in the above flowchart. (A.O.)

  8. Examination of purchasing power parity hypothesis: Evidence from unit root and cointegration analysis of dinar-euro and dinar-dollar exchange rates

    OpenAIRE

    Petrović, Predrag

    2014-01-01

    The paper shows the results of an empirical analysis of the relative variant of purchasing power parity (PPP) for dinar-euro and dinar-dollar ex-change rates. The study was conducted for the period January 2007 - August 2013 and involved testing of the empirical foundation of strong and weak PPP forms. The first part of the strong PPP form testing comes down to examination of non-stationarity of dinar-euro and dinar-dollar real exchange rates by use of standard unit root tests (ADF, PP, KPSS,...

  9. Development of the testing procedure for units and elements of mining equipment

    Directory of Open Access Journals (Sweden)

    P. B. Gerike

    2017-09-01

    Full Text Available The author considers in detail the stages of creating a testing procedure for mining equipment based on the complex implementation of principles of nondestructive testing and technical diagnostics. The author substantiates effectiveness of application of a complex diagnostic approach for assessing the state of metal structures and energy-mechanical equipment of mining machines. The opportunity for timely detection of defects, regardless of their type and degree of danger, presents itself only with a wide application of the modern methods of vibration diagnostics and nondestructive testing. The author substantiates the effectiveness of specific combination of methods of nondestructive testing, most optimally suited for solving given tasks. The article contains the developed complex of more than 120 diagnostic rules, suitable for performing automated analysis of vibroacoustic signal and revealing the main damages of energy-mechanical equipment based on selective groups of informative frequencies. The author formulates the main criteria that one can use as a basic platform for improving the methodology for normalizing the parameters of mechanical oscillations. The developed diagnostic criteria became a basis for the development of individual spectral masks suitable for performing the analysis of parameters of vibroacoustic waves generated during operation of mining equipment. The author proves necessity of transition of repair and maintenance divisions of industrial enterprises to the system of maintenance of machinery according to its actual technical state, and the developed complex of diagnostic rules for detecting defects can serve as a platform for the implementation of basic elements of this system. The author substantiates the principal validity of the developed methodology for testing mining machines equipment and its individual elements, such as the predictive modeling of degradation of technical state of mining equipment and the

  10. Integrated software system for improving medical equipment management.

    Science.gov (United States)

    Bliznakov, Z; Pappous, G; Bliznakova, K; Pallikarakis, N

    2003-01-01

    The evolution of biomedical technology has led to an extraordinary use of medical devices in health care delivery. During the last decade, clinical engineering departments (CEDs) turned toward computerization and application of specific software systems for medical equipment management in order to improve their services and monitor outcomes. Recently, much emphasis has been given to patient safety. Through its Medical Device Directives, the European Union has required all member nations to use a vigilance system to prevent the reoccurrence of adverse events that could lead to injuries or death of patients or personnel as a result of equipment malfunction or improper use. The World Health Organization also has made this issue a high priority and has prepared a number of actions and recommendations. In the present workplace, a new integrated, Windows-oriented system is proposed, addressing all tasks of CEDs but also offering a global approach to their management needs, including vigilance. The system architecture is based on a star model, consisting of a central core module and peripheral units. Its development has been based on the integration of 3 software modules, each one addressing specific predefined tasks. The main features of this system include equipment acquisition and replacement management, inventory archiving and monitoring, follow up on scheduled maintenance, corrective maintenance, user training, data analysis, and reports. It also incorporates vigilance monitoring and information exchange for adverse events, together with a specific application for quality-control procedures. The system offers clinical engineers the ability to monitor and evaluate the quality and cost-effectiveness of the service provided by means of quality and cost indicators. Particular emphasis has been placed on the use of harmonized standards with regard to medical device nomenclature and classification. The system's practical applications have been demonstrated through a pilot

  11. Seismic design margin evaluation of systems and equipment required for safe shutdown of North Anna, Units 1 and 2, following an SSE (safe-shutdown earthquake) event. Technical report

    International Nuclear Information System (INIS)

    Desai, K.D.

    1981-06-01

    The Advisory Committee on Reactor Safeguards recommended that the NRC staff review in detail the capability and available seismic design margin of fluid systems and equipment used in North Anna, Units 1 and 2 to achieve safe shutdown following a site-design safe-shutdown earthquake (SSE). The staff conducted a series of plant visits and meetings with the licensee to view and discuss the seismic design methodology used for systems, equipment and their supports. The report is a description and evaluation of the seismic design criteria, design conservatisms and seismic design margin for North Anna, Units 1 and 2

  12. 47 CFR 69.306 - Central office equipment (COE).

    Science.gov (United States)

    2010-10-01

    ... that any Central office equipment attributable to local transport shall be assigned to the Transport... Information and Transport access elements based on the remaining combined investment in COE Category 1... equipment for purposes of the Modification of Final Judgment in United States v. Western Electric Co. shall...

  13. The use of Hewlett Packard minicomputers for data acquisition and data analysis in heat exchanger research and development

    International Nuclear Information System (INIS)

    Lepp, R.M.; Mastorakos, J.; Shaw, J.D.; Tromp, J.H.

    1984-07-01

    Failures in heat exchange equipment are usually caused by vibration-induced fatigue or fretting wear, or by corrosion. The need for high reliability and performance of this equipment, particularly in nuclear power plants, has resulted in research and development programs on heat exchangers at the Chalk River Nuclear Laboratories. Much of this work has been experimental, requiring the use of computer-based data acquisition/analysis systems. The way in which we have satisfied these needs using equipment supplied by Hewlett-Packard is described

  14. A novel algorithm for demand-control of a single-room ventilation unit with a rotary heat exchanger

    DEFF Research Database (Denmark)

    Smith, Kevin Michael; Jansen, Anders Lund; Svendsen, Svend

    in the indoor environment. Based on these values, a demand-control algorithm varies fan speeds to change airflow rates and varies the rotational speed of the heat exchanger to modulate heat and moisture recovery. The algorithm varies airflow rates to provide free cooling and limit CO2 concentrations and varies...... moisture recovery by varying the rotational speed and then safely unbalances airflows in a worst-case scenario. In the algorithm, frost protection and minimum supply temperature take the highest priority and override other controls. This paper documents the proposed demand control algorithm and analyses...... its impacts on compliance of building regulations in Denmark. The paper presents an algorithm that manufacturers can program into their controls. The commercially available single-room ventilation unit with a rotary heat exchanger uses this algorithm coded in the C language. Future work will document...

  15. Ion exchange/adsorbent pilot plant

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    A decontamination of greater than 99% of the actinides and fission products contained in radioactive waste water can be obtained using ion exchange resins. A system for achieving this result is described in this paper. This ion exchange pilot-plant design is the culmination of five years of study of the decontamination of radioactive waste streams by ion exchange resins and other adsorbents at Mound. In order to maintain maximum flexibility of treatments, this pilot-plant design is a conceptual design with specific flows, resins, and column specifications, but with many optional features and no rigid equipment specifications. This flexibility allows the system to be amenable to almost any radioactive waste stream. Very specific designs can be constructed from this conceptual design for the treatment of any specific waste stream. Operating and capital costs are also discussed. 1 figure, 5 tables

  16. Incineration of ion-exchange resins

    International Nuclear Information System (INIS)

    Valkiainen, M.; Nykyri, M.

    1985-01-01

    Incineration of ion-exchange resins in a fluidized bed was studied on a pilot plant scale at the Technical Research Centre of Finland. Both granular and powdered resins were incinerated in dry and slurry form. Different bed materials were used in order to trap as much cesium and cobalt (inactive tracers) as possible in the bed. Also the sintering of the bed materials was studied in the presence of sodium. When immobilized with cement the volume of ash-concrete is 4 to 22% of the concrete of equal compressive strength acquired by direct solidification. Two examples of multi-purpose equipment capable of incinerating ion-exchange resins are presented. (orig.)

  17. Equipment for biomass. Wood burners; Materiels pour la biomasse, les chaudieres bois

    Energy Technology Data Exchange (ETDEWEB)

    Chieze, B. [SA Compte R., 63 - Arlanc (France)

    1997-12-31

    A review of the French classification of biomass wastes (and more especially wood and wood wastes) concerning classified burning equipment, is presented: special authorization is thus needed for burning residues from wood second transformation processes. Limits for combustion product emission levels are detailed and their impact on wood burning and process equipment is examined: feeder, combustion chamber, exchanger, fume treatment device, residue disposal. Means for reducing pollutant emissions are reviewed

  18. Monorail Piccolino catheter: a new rapid exchange/ultralow profile coronary angioplasty system.

    Science.gov (United States)

    Mooney, M R; Douglas, J S; Mooney, J F; Madison, J D; Brandenburg, R O; Fernald, R; Van Tassel, R A

    1990-06-01

    The Monorail Piccolino coronary angioplasty balloon catheter (MBC) was evaluated on 118 patients at two centers. Technical success was achieved in 110 patients (93%). Time for catheter exchange and total fluoroscopy time were significantly lower for the Monorail catheter than with standard equipment (exchange time 97 vs. 170 seconds P less than .05 and fluoroscopy time 17 vs. 88 seconds P less than .001). The advantages of rapid exchange and the ability of utilize 2 Monorail balloon catheters through one 9F guiding catheter for simultaneous inflations allowed for maximal flexibility in treating patients with bifurcation lesions. The double wire approach utilizing one Monorail balloon catheter with a 7F guiding catheter was also technically successful. The Monorail Piccolino balloon catheter has unique features that allow for greater ease of operator use, rapid catheter exchange, and optimal angiographic visualization. It is felt that this catheter design provides distinct advantages over standard angioplasty equipment.

  19. Compact heat exchanger for power plants

    International Nuclear Information System (INIS)

    Kinnunen, L.

    2001-01-01

    Vahterus Oy, located at Kalanti, has manufactured heat exchangers since the beginning of 1990s. About 90% of the equipment produced are exported. In the PSHE (Plate and Shell) solution of the Vahterus heat exchanger the heat is transferred by round plated welded to form a compact package, which is assembled into a cylindrical steel casing. The heat exchanger contains no gaskets or soldered joints, which eliminates the leak risks. Traditional heat exchanges are usually operated at higher temperatures and pressures, but the heat transfer capacities of them are lower. Plate heat exchangers, on the other hand, are efficient, but the application range of them is narrow. Additionally, the rubber gasket of the heat exchange plates, sealing the joints of the heat exchanging plates, does not stand high pressures or temperatures, or corroding fluids. The new welded plate heat exchanger combine the pressure and temperature resistance of tube heat exchangers and the high heat exchange capacity of plate heat exchangers. The new corrosion resisting heat exchanger can be applied for especially hard conditions. The operating temperature range of the PSHE heat exchanger is - 200 - 900 deg C. The pressure resistance is as high as 100 bar. The space requirement of PSHE is only one tenth of the space requirement of traditional tube heat exchangers. Adjusting the number of heat exchanging plates can change the capacity of the heat exchanger. Power range of the heat exchanger can be as high as 80 MW. Due to the corrosion preventive construction and the small dimension the PSHE heat exchanger can be applied for refrigerators using ammonia as refrigerant. These kinds of new Vahterus heat exchangers are in use in 60 countries in more than 2000 refrigerators

  20. Thermodynamic evaluation of a kerosene pre- Fraction unit using energy and exergy analysis

    Directory of Open Access Journals (Sweden)

    Ehsan Ghasemi

    2017-09-01

    Full Text Available This work applies the method of energy and exergy analysis over first step of linear alkyl benzene (LAB production namely kerosene pre fraction plant, to determine unit energy and exergy performance and loss, besides of opportunities for improvement based on operational data. For this purpose macroscopic energy and exergy balance was developed over main equipment including electro pumps, heat exchangers, air coolers, and distillation columns. The results shows that total energy performance of plant is 92.62% by 19.76 MW energy lost, while from exergy perspective, unit performance is 78.08% by 17.92 MW exergy lost. Maximum local exergy lost occurs in the feed pre heater exchanger by 27% performance which is designed to recover energy from top product of second column, furthermore results shows that upgrading low quality energy in air coolers based on heat pump concept would protect energy and exergy emission to the environment and reduce 40% of total lost energy and 16% of total lost exergy in plant.

  1. Development of Information Datasheets of Nuclear Power Plant (NPP) Equipment using cfiXLM schema

    International Nuclear Information System (INIS)

    Lee, Jaiho; Song, Eunhye

    2014-01-01

    In 2009, EPRI (Electrical Power Research Institute) published a new NPP information handover guide to provide NPP owners and operators with data handover templates in consistent format for effective delivery of information during all stages of the handover process. Another difficult concern for NPP data information management is to exchange the data information among many organizations such as NPP owners, operators, engineering companies, suppliers, and vendors. As a matter of fact, the improperly formatted handover of information sometimes occurs due to the discrepancy of data format (e. g., data description language type). This improper delivery can make negative effects on NPP integrity and safety. Thus, the lack of proper exchange for different data information systems of organizations should be resolved by using an international standard data format. The standard data format can reduce the cost and time for data exchange in each phase for design, procurement, delivery, installation, operation and maintenance of equipment. The AEX(automating equipment information exchange) pilot implementation project team under EPRI advanced nuclear technology (ANT) program has been conducted a research for the use of XML equipment schemas for electronic data exchange(EDE). They applied XML equipment schema for the design, selection, quotation, purchase and mock install of a safety injection centrifugal pump using EDE standard HI(hydraulic institute) 50.7. For data exchange, FIATECH, an industry consortium, has equally developed library of templates and reference data for ISO-15926, which is an international standard capable of reducing data-error and delivery time for exchanging data among different organizations. KHNP as an only owner/operator company has not experienced much difficulty in data interoperability with other organizations, but continued its unremitting exertions to develop a robust system capable of managing data information generated in all the stages of NPP

  2. Development of Information Datasheets of Nuclear Power Plant (NPP) Equipment using cfiXLM schema

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jaiho; Song, Eunhye [KHNP-Central Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    In 2009, EPRI (Electrical Power Research Institute) published a new NPP information handover guide to provide NPP owners and operators with data handover templates in consistent format for effective delivery of information during all stages of the handover process. Another difficult concern for NPP data information management is to exchange the data information among many organizations such as NPP owners, operators, engineering companies, suppliers, and vendors. As a matter of fact, the improperly formatted handover of information sometimes occurs due to the discrepancy of data format (e. g., data description language type). This improper delivery can make negative effects on NPP integrity and safety. Thus, the lack of proper exchange for different data information systems of organizations should be resolved by using an international standard data format. The standard data format can reduce the cost and time for data exchange in each phase for design, procurement, delivery, installation, operation and maintenance of equipment. The AEX(automating equipment information exchange) pilot implementation project team under EPRI advanced nuclear technology (ANT) program has been conducted a research for the use of XML equipment schemas for electronic data exchange(EDE). They applied XML equipment schema for the design, selection, quotation, purchase and mock install of a safety injection centrifugal pump using EDE standard HI(hydraulic institute) 50.7. For data exchange, FIATECH, an industry consortium, has equally developed library of templates and reference data for ISO-15926, which is an international standard capable of reducing data-error and delivery time for exchanging data among different organizations. KHNP as an only owner/operator company has not experienced much difficulty in data interoperability with other organizations, but continued its unremitting exertions to develop a robust system capable of managing data information generated in all the stages of NPP

  3. Geothermal rice drying unit in Kotchany, Macedonia

    International Nuclear Information System (INIS)

    Popovski, K.; Dimitrov, K.; Andrejevski, B.; Popovska, S.

    1992-01-01

    A geothermal field in Kotchany (Macedonia) has very advantageous characteristics for direct application purposes. Low content of minerals, moderate temperature (78C) and substantial available geothermal water flow (up to 300 1/s) enabled the establishment of a district heating scheme comprising mainly agricultural and industrial uses. A rice drying unit of 10 t/h capacity was installed 8 years ago, using the geothermal water as the primary heat source. A temperature drop of 75/50C enables the adaptation of conventional drying technology, already proven in practice in the surrounding rice growing region. Water to air heat exchanger and all necessary equipment and materials are of local production, made of copper and carbon steel. The use of such drying units is strongly recommended for the concrete district heating scheme because it offers a very simple geothermal application and enables improvement in the annual heating load factor without high investments in geothermal water distribution lines

  4. Ion exchange : principles and applications

    International Nuclear Information System (INIS)

    Bank, Nader; Majumdar, A.S.

    1975-01-01

    An attempt is made to provide a brief state-of-the-art review of the basic principles underlying the unit operation of ion exchange and its numerous and diverse commercial applications. A selective bibliography is provided for the benefit of the reader interested in pursuing any specific aspect of ion exchange. (author)

  5. After-hours power status of office equipment and energy use of miscellaneous plug-load equipment

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Marageret J.; Busch, John F.

    2004-05-27

    This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of miscellaneous plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers. For most types of miscellaneous equipment, we also estimated typical unit energy consumption in order to estimate total energy consumption of the miscellaneous devices within our sample. This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from sixteen commercial buildings in California, Georgia, and Pennsylvania: four education buildings, two medical buildings, two large offices (> 500 employees each), three medium offices (50-500 employees each), and five small

  6. 21 CFR 1210.15 - Pasteurization; equipment and methods.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pasteurization; equipment and methods. 1210.15... UNDER THE FEDERAL IMPORT MILK ACT Inspection and Testing § 1210.15 Pasteurization; equipment and methods... into the United States shall employ adequate pasteurization machinery of a type easily cleaned and of...

  7. Variable Temperature Equipment for a Commercial Magnetic Susceptibility Balance

    Science.gov (United States)

    Lotz, Albert

    2008-01-01

    Variable temperature equipment for the magnetic susceptibility balance MSB-MK1 of Sherwood Scientific, Ltd., is described. The sample temperature is controlled with streaming air heated by water in a heat exchanger. Whereas the balance as sold commercially can be used only for room temperature measurements, the setup we designed extends the…

  8. Common floor system vertical earthquake-proof structure for reactor equipment

    International Nuclear Information System (INIS)

    Morishita, Masaki.

    1996-01-01

    In an LMFBR type reactor, a reactor container, a recycling pump and a heat exchanger are disposed on a common floor. Vertical earthquake-proof devices which can be stretched only in vertical direction formed by laminating large-sized bellevilles are disposed on a concrete wall at the circumference of each of reactor equipments. A common floor is placed on all of the vertical earthquake-proof devices to support the entire earthquake-proof structure simultaneously. If each of reactor equipments is loaded on the common floor and the common floor is entirely supported against earthquakes altogether, since the movement of each of the reactor equipments loaded on the common floor is identical, relative dislocation is not exerted on the main pipelines which connect the equipments. In addition, since the entire earthquake structure has a flat common floor and each of the reactor equipments is suspended to minimize the distance between a gravitational center and a support point, locking vibration is less caused to the horizontal earthquake. (N.H.)

  9. 7 CFR 3015.170 - Damage, loss, or theft of equipment.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Damage, loss, or theft of equipment. 3015.170 Section... Damage, loss, or theft of equipment. (a) Applicability. This section applies to equipment with a unit... damage, loss, or theft, the recipient does not have a control system in effect as required by § 3015.169...

  10. Structure design of primary heat-exchanger for the MHWRR

    International Nuclear Information System (INIS)

    Li Yanshui; Cao Zhibin

    1999-01-01

    Primary heat-exchanger is one of the key equipment in the Multi-application Heavy Water Research Reactor (MHWRR). Its structure design ought to meet as much possible as the demands for safety, feasibility and economy. To reduce the liquid resistance, the locating structure between inner tube and outer tube is distributed spirally. The edge of outer tube is processed in the shape of hexahedron and then splice-welded into honeycomb structure thereby the heat-exchanger has the smallest outer diameter compared with that with the same heat-exchanging area according to 'Normal Design', 'Anabasis Design' is applied to the design for parts with Safety Class I, to ensure safety of the heat-exchanger

  11. Optimum Design of Heat Exchangers Networks Part-2: case study: Atmospheric Crude Distillation Unit

    International Nuclear Information System (INIS)

    Gabr, E.M.A.; EI-Temtamy, S.A.; Deriasl, S.F.; Moustafa, H.A.

    2004-01-01

    In this paper the computerized framework introduced in part-I for Heat Exchanger Network Synthesis (HENS) with optimality conditions of achieving the least operating and capital cost has been applied on an industrial atmospheric distillation unit existing in one of the Egyptian refineries . The application includes two types of designing: grass-root and revamp of the existing design. For the final grass-root design, the saving of utilities is 50% of the actual consumption while the net annual saving reaches 2,193,690 S/year .For revamping of existing design the % saving of hot and cold utilities are 38.1% and 43.2% respectively and the annual saving of 1,723,104 $/year is achieved

  12. Overall Equipment Effectiveness Implementation Criteria

    Science.gov (United States)

    Abramova, I. G.; Abramov, D. A.

    2018-01-01

    This article documents the methods applied in production control technics specifically focused on commonly used parameter OEE (Overall Equipment Effectiveness). The indicators of extensive and intensive use of equipment are considered. Their appointment this is comparison in the same type of production within the industry and comparison of single-type and / or different types of equipment in terms of capacity. However, it is shown that there is no possibility of revealing the reasons for the machine’s operation: productive / unproductive, with disturbances. Therefore, in the article reveals the approaches to calculating the indicator characterizing the direct operation of the equipment. The Machine Load coefficient is approaching closely to the indicator of the efficiency of the use of equipment. Methods analysis is proceeded through the historically applied techniques such as “Stopwatch” and “Motion” studies. Was performed the analysis of the efficiency index of OEE equipment using the comparable indexes performance of equipment in the Russian practice. An important indicator of OEE contains three components. The meaning of each of them reflects historically applicable indicators. The value of the availability of equipment indicator is close to the value of the equipment extensibility index. The value of the indicator of the efficiency of work can be compared with the characteristic of the capacity of the equipment and the indicator of the quality level can meet the requirements for compliance with the manufacturing technology. Shown that the sum of the values of the coefficient of “Availability” of the equipment and the value of the “Factor of compaction of working hours” are one. As well as the total value of the indicator “level of quality” and the coefficient of marriage given in the result unit. The measurability of the indicators makes it possible to make a prediction about efficiency of the equipment.

  13. Research kinetic of motion of milling bodies in ball mill, outfit heat-exchange unit and calculation of its energy performance

    Science.gov (United States)

    Romanovich, A. A.; Romanovich, M. A.; Apukhtina, I. V.

    2018-03-01

    The article considers topical issues of energy saving in cement production with the use of a technological grinding complex, which includes a press roller grinder and a ball mill. Rational conditions of grinding are proposed for pre-shredded material through the installation of blade energy exchange devices (BEED) in the mill drum. The loading level in the first chamber varies periodically depending on the drum rotation angle, equipped with BEED. In the zone of BEED’s active action, there is a “scooping” of a part of grinding bodies together with crushed material, raising them to a height and giving them a longitudinally transverse movement, which is different from movement created in the mill without BEED. At the same time, additional work that consumes engine power is being done. A technique is proposed for calculating the additional engine power consumption of a mill, equipped with a BEED. This power is spent on creating a longitudinal-transverse motion of grinding bodies and its first and second chambers in areas of active influence of the BEED. Comparative analysis of results obtained experimentally and calculations of proposed equations show a high convergence of results. These analytical dependencies may be interest to Russian and foreign organizations that carry out their activities in the field of design and manufacture of cement equipment, as well as to cement producers.

  14. What do we know about real exchange rate non-linearities?

    DEFF Research Database (Denmark)

    Kruse, Robinson; Frömmel, Michael; Menkhoff, Lukas

    correctly and misspecified non-linear alternatives is analyzed by means of a Monte Carlo study. The chosen parametrization is obtained by real-life exchange rates. The test against ESTAR has low power against all alternatives whereas the proposed unit root test against a Markov Switching autoregressive......This research points to the serious problem of potentially misspecified alternative hypotheses when testing for unit roots in real exchange rates. We apply a popular unit root test against nonlinear ESTAR and develop a Markov Switching unit root test. The empirical power of these tests against...... model performs clearly better. An empirical application of these tests suggests that real exchange rates may indeed be explained by Markov-Switching dynamics....

  15. Conjugate heat and mass transfer in heat mass exchanger ducts

    CERN Document Server

    Zhang, Li-Zhi

    2013-01-01

    Conjugate Heat and Mass Transfer in Heat Mass Exchanger Ducts bridges the gap between fundamentals and recent discoveries, making it a valuable tool for anyone looking to expand their knowledge of heat exchangers. The first book on the market to cover conjugate heat and mass transfer in heat exchangers, author Li-Zhi Zhang goes beyond the basics to cover recent advancements in equipment for energy use and environmental control (such as heat and moisture recovery ventilators, hollow fiber membrane modules for humidification/dehumidification, membrane modules for air purification, desi

  16. International Trade in Environmental Protection Equipment: An Assessment of Existing Data (1993)

    Science.gov (United States)

    Study estimates total U.S. imports, exports, and trade balances for environmental protection (EP) equipment between 1980-1991. While the United States is a major exporter of EP equipment, trade in EP equipment constitutes a small percent of total US trade.

  17. Calibration of an inertial-magnetic measurement unit without external equipment, in the presence of dynamic magnetic disturbances

    International Nuclear Information System (INIS)

    Metge, J; Giremus, A; Mégret, R; Berthoumieu, Y; Décamps, T

    2014-01-01

    Inertial-magnetic measurement units are inexpensive sensors, widely used in electronic systems (smartphones, GPS, micro-UAV, etc). However the precision of these sensors is highly dependent on their calibration. This article proposes a complete solution to calibrate the sensors (accelerometers, gyrometers and magnetometers), the inter-sensor rotations and the dynamic disturbances of the magnetic field due to the immediate environment. Contrary to most of the existing techniques, the proposed method does not necessitate any external equipment, apart from the sensors already included in the system. The calibration can be performed by hand manipulation by the final user. Simulations and experiments show the advantages of the proposed approach. (paper)

  18. Associations between perceived crisis mode work climate and poor information exchange within hospitals.

    Science.gov (United States)

    Patterson, Mark E; Bogart, Miller S; Starr, Kathleen R

    2015-03-01

    Because hospital units operating in crisis mode could create unsafe transitions of care due to miscommunication, our objective was to estimate associations between perceived crisis mode work climate and patient information exchange problems within hospitals. Self-reported data from 247,140 hospital staff members across 884 hospitals were obtained from the 2010 Hospital Survey on Patient Safety Culture. Presence of a crisis mode work climate was defined as respondents agreeing that the hospital unit in which they work tries to do too much too quickly. Presence of patient information exchange problems was defined as respondents agreeing that problems often occur in exchanging patient information across hospital units. Multivariable ordinal regressions estimated the likelihood of perceived problems in exchanging patient information across hospital units, controlling for perceived levels of crisis mode work climate, skill levels, work climate, and hospital infrastructure. Compared to those disagreeing, hospital staff members agreeing that the hospital unit in which they work tries to do too much too quickly were 1.6 times more likely to perceive problems in exchanging patient information across hospital units (odds ratio: 1.6, 95% confidence interval: 1.58-1.65). Hospital staff members perceiving crisis mode work climates within their hospital unit are more likely to perceive problems in exchanging patient information across units, underscoring the need to improve communication during transitions of care. © 2014 Society of Hospital Medicine.

  19. Experience with rotating equipment in FBTR

    International Nuclear Information System (INIS)

    Babu, A.; Subramanian, K.G.; Selvam, B.

    2006-01-01

    Fast breeder test reactor (FBTR) is a 40MWth sodium cooled PuC-UC fuelled fast breeder reactor located at Kalpakkam, Tamilnadu. FBTR has a variety of mechanical and electrical equipment comprising of single stage and multi stage water pumps, sodium pumps, compressors, Chiller units, Diesel Generator sets, vacuum pumps, ventilation fans, Turbo generator etc. The degree and extent of maintenance on these equipment are decided based on nuclear safety, station technical specification requirements, design criteria and operating philosophy. The variety and complexity of the equipment in FBTR demands various maintenance strategies (preventive, predictive, proactive etc.) for their upkeep. This paper discusses the performance of all mechanical and electrical equipment in FBTR, measures taken for their upkeep, major modifications done to prevent recurring failures, condition monitoring programme implemented, Maintenance Management and Information System developed for data acquisition and dissemination, etc. (author)

  20. Experts and equipment for atomic development. An outline of the IAEA programme for 1963

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1963-04-15

    Thirty-seven countries will this year receive technical assistance from the International Atomic Energy Agency in the form of services of experts and equipment for their atomic energy programmes. The Agency will send out about 80 experts and provide more than $450 000 worth of equipment. The Agency's 1963 budget provides for an expenditure of $864 000 for this form of assistance to its Member States. This is part of a total operational programme (including exchange and training of scientists) of a little over 2. 2 million dollars, to be financed almost entirely out of voluntary contributions to the Agency's General Fund. The contributions made or pledged so far, however, fall short of the target, which was set at $2 million, and consequently the allocations for various parts of the programme will have to be reduced. It is expected that $713 000 will be available for the provision of experts and equipment out of contributions to the General Fund. In addition, the Agency's share in the approved United Nations Expanded Programme of Technical Assistance (EPTA) on 1 January 1963 provided nearly $573 000 for experts, visiting professors and equipment for this year. The total value of this kind of assistance to be given by the Agency this year will therefore be of the order of $ 1 286 000. The experts will represent various branches of nuclear science and technology, and the equipment, too, will be varied, the nature of the projects for assistance being determined by the specific needs of individual Member States. This can be seen from the following brief account of the assistance to be given to each country. (For the sake of convenience, the countries have been arranged in a few geographical groups.)

  1. AVM branch vibration test equipment

    International Nuclear Information System (INIS)

    Anne, J.P.

    1995-01-01

    An inventory of the test equipment of the AVM Branch ''Acoustic and Vibratory Mechanics Analysis Methods'' group has been undertaken. The purpose of this inventory is to enable better acquaintance with the technical characteristics of the equipment, providing an accurate definition of their functionalities, ad to inform potential users of the possibilities and equipment available in this field. The report first summarizes the various experimental surveys conduced. Then, using the AVM equipment database to draw up an exhaustive list of available equipment, it provides a full-scope picture of the vibration measurement systems (sensors, conditioners and exciters) and data processing resources commonly used on industrial sites and in laboratories. A definition is also given of a mobile test unit, called 'shelter', and a test bench used for the testing and performance rating of the experimental analysis methods developed by the group. The report concludes with a description of two fixed installations: - the calibration bench ensuring the requisite quality level for the vibration measurement systems ; - the training bench, whereby know-how acquired in the field in the field of measurement and experimental analysis processes is made available to others. (author). 27 refs., 15 figs., 2 appends

  2. Radioactive decontamination of equipment

    International Nuclear Information System (INIS)

    1982-03-01

    After a recall of some definitions relating to decontamination techniques and of the regulation into effect, the principles to be respected to arrange rationally work zones are quoted while insisting more particularly on the types of coatings which facilitate maintenance operations and the dismantling of these installations. Then, the processes and equipments to use in decontamination units for routine or particular operations are described; the list of recommended chemical products to decontaminate the equipment is given. The influence of these treatments on the state and the duration of life of equipments is studied, and some perfectible methods are quoted. In the appendix, are given: the limits of surface contamination accepted in the centers; a standard project which defines the criteria of admissible residual contamination in wastes considered as cold wastes; some remarks on the interest that certain special ventilation and air curtain devices for the protection of operators working on apparatus generating contaminated dusts [fr

  3. The application and practice of predictive maintenance at CANDU equipment management

    International Nuclear Information System (INIS)

    Yu Guangting

    2014-01-01

    The equipment in Qinshan CANDU unit is characterized by large number and complex structure. Some equipment failure has no relation with the operation time, it is impossible to avoid the failure of these equipment only by periodical maintenance. To improve the equipment reliability, increase the equipment usability and decrease the maintenance cost, for important equipment related to nuclear safety and generating electricity, it is required to perform condition monitoring and the predictive maintenance (PdM). According to different characteristics of equipment, it is required to use suitable equipment condition monitoring method, content and frequency. In this way, some potential equipment failure can be found, preventive maintenance can be arranged in advance, and equipment maintenance management can be optimized. (author)

  4. Control of peripheral units by satellite computer

    International Nuclear Information System (INIS)

    Tran, K.T.

    1974-01-01

    A computer system was developed allowing the control of nuclear physics experiments, and use of the results by means of graphical and conversational assemblies. This system which is made of two computers, one IBM-370/135 and one Telemecanique Electrique T1600, controls the conventional IBM peripherals and also the special ones made in the laboratory, such as data acquisition display and graphics units. The visual display is implemented by a scanning-type television, equipped with a light-pen. These units in themselves are universal, but their specifications were established to meet the requirements of nuclear physics experiments. The input-output channels of the two computers have been connected together by an interface, designed and implemented in the Laboratory. This interface allows the exchange of control signals and data (the data are changed from bytes into word and vice-versa). The T1600 controls the peripherals mentionned above according to the commands of the IBM370. Hence the T1600 has here the part of a satellite computer which allows conversation with the main computer and also insures the control of its special peripheral units [fr

  5. Performance Analysis of Window Type Air Conditioning with Addition of Heat Exchanger Equipment

    Directory of Open Access Journals (Sweden)

    I Ketut Gede Wirawan

    2012-11-01

    Full Text Available One manner to be used to increase refregration effect is by flowing hot refrigerant out from condensor, it is then touched with the refrigerant out from evaporator on a heat exchanger of counterflow type. Experiment was done by taking samples of pressure at suction (p1 and discharge (p2 of compressor and box temperature (Tr1, Tr2, Tr3, Tr4. By knowing of pressure at suction (p1, the enthalpy into compressor is known. By assuming the process is isentropic (compressor, isobar (condenser and evaporator, and isenthalpy (expansion valve, the enthalpy into condensor, expansion valve and evaporator were known. In 60 minutes, compression work of air conditioning with heat exchanger is 31,588 kJ/kg, and without heat exchanger is 33,796 kJ/kg. Effect refrigeration average with modification is 155,55 kJ/kg and without modification was 153,40 kJ/kg so that coefficient of performance with modification more than without modification. Air conditioning with modification had initial refrigration rate was 67,193 J/s and 0,043 J/s at the end minute, meanwhile, refrigeration without modification had cooling rate at start 66,538 J/s and 0,935 J/s at the end.

  6. Nuclear electronic equipment for control and monitoring boards. Susceptibility of nuclear electronic pulse equipment to interference

    International Nuclear Information System (INIS)

    Buisson, Jacques; Cochinal, R.; Duquesnoy, J.; Roquefort, H.

    1972-07-01

    The correct functioning of pulse measurement units in industrial environmental conditions where interference is high, frequently gives rise to many installation problems which are difficult to solve. This paper offers some recommendations with a view to minimising the effect to electric interference on electronic equipment and gives a test method which enables this effect to be assessed qualitatively. It has been devised for nuclear electronic instrumentation but it may also be applied to other equipment and in particular the test method may be used for other cases. After a few preliminaries on how interference acts and on the terminology, the design of the equipment and the recommended connections are mentioned. Test methods are then indicated, followed by various technical comments. (author) [fr

  7. Development of new process network for gas chromatograph and analyzers connected with SCADA system and Digital Control Computers at Cernavoda NPP Unit 1

    International Nuclear Information System (INIS)

    Deneanu, Cornel; Popa Nemoiu, Dragos; Nica, Dana; Bucur, Cosmin

    2007-01-01

    The continuous monitoring of gas mixture concentrations (deuterium/ hydrogen/oxygen/nitrogen) accumulated in 'Moderator Cover Gas', 'Liquid Control Zone' and 'Heat Transport D 2 O Storage Tank Cover Gas', as well as the continuous monitoring of Heavy Water into Light Water concentration in 'Boilers Steam', 'Boilers Blown Down', 'Moderator heat exchangers', and 'Recirculated Water System', sensing any leaks of Cernavoda NPP U1 led to requirement of developing a new process network for gas chromatograph and analyzers connected to the SCADA system and Digital Control Computers of Cernavoda NPP Unit 1. In 2005 it was designed and implemented the process network for gas chromatograph which connected the gas chromatograph equipment to the SCADA system and Digital Control Computers of the Cernavoda NPP Unit 1. Later this process network for gas chromatograph has been extended to connect the AE13 and AE14 Fourier Transform Infrared (FTIR) analyzers with either. The Gas Chromatograph equipment measures with best accuracy the mixture gases (deuterium/ hydrogen/oxygen/nitrogen) concentration. The Fourier Transform Infrared (FTIR) AE13 and AE14 Analyzers measure the Heavy Water into Light Water concentration in Boilers Steam, Boilers BlownDown, Moderator heat exchangers, and Recirculated Water System, monitoring and signaling any leaks. The Gas Chromatograph equipment and Fourier Transform Infrared (FTIR) AE13 and AE14 Analyzers use the new OPC (Object Link Embedded for Process Control) technologies available in ABB's VistaNet network for interoperability with automation equipment. This new process network has interconnected the ABB chromatograph and Fourier Transform Infrared analyzers with plant Digital Control Computers using new technology. The result was an increased reliability and capability for inspection and improved system safety

  8. Essential Specification Elements for Heat Exchanger Replacement

    Energy Technology Data Exchange (ETDEWEB)

    Bower, L.

    2015-07-01

    Performance upgrade and equipment degradation are the primary impetuses for a nuclear power plant to engage in the large capital cost project of heat exchanger replacement. Along with attention to these issues, consideration of heat exchanger Codes and Standards, material improvements, thermal redesign, and configuration are essential for developing User’s Design Specifications for successful replacement projects. The User’s Design Specification is the central document in procuring ASME heat exchangers. Properly stated objectives for the heat exchanger replacement are essential for obtaining the materials, configurations and thermal designs best suited for the nuclear power plant. Additionally, the code of construction required and the applied manufacturing standard (TEMA or HEI) affects how the heat exchanger may be designed or configured to meet the replacement goals. Knowledge of how Codes and Standards affect design and configuration details will aid in writing the User’s Design Specification. Joseph Oat Corporation has designed and fabricated many replacement heat exchangers for the nuclear power industry. These heat exchangers have been constructed per ASME Section III to various Code-Years or ASME Section VIII-1 to the current Code-Year also in accordance with TEMA and HEI. These heat exchangers have been a range of like-for-like replacement to complete thermal, material and configuration redesigns. Several examples of these heat exchangers with their Code, Standard and specification implications are presented. (Author.

  9. Plate heat exchangers in air conditioning applications. Development of air-coolers, air-heaters and air-conditioning units with low pressure loss. Plattenwaermetauscher in raumlufttechnischen Anlagen. Entwicklung stroemungsoptimierter Luftkuehler, Lufterhitzer und Klimageraete

    Energy Technology Data Exchange (ETDEWEB)

    Bach, H; Diemer, R; Eisenmann, G; Goettling, D; Madjidi, M

    1989-08-01

    To prepare the development of a water to air plate heat exchanger the state of the art, i.e. the technological knowhow and the design basis are given. The concept and ideas are presented which lead to a slightly wavy plate. Furthermore an exemplary design of a plate heat exchanger and an air-conditioning unit is described and finally the application of plate heat exchangers as direct evaporators and the potential icing problems are investigated. Comparing measured and calculated data shows that the performance of plates with plane surfaces can be predicted fairly well by the presented design methods. The performance of plates with strongly wavy surface however has to be measured. Optimization calculations yield to an air gap of slightly over 4 mm. Comparison with an air-conditioning unit demonstrates that the strongest advantage is for the air cooler (one third of the pressure loss) that a new concept of an air-conditioning unit has lower losses in the fan unit and that it does not need an eliminator. This results in half the volume for the new unit, in a pressure drop of 88%, fan power of 90% and fan revolutions of 50%. (orig./GL).

  10. Triple-membrane reduces need for ion exchange regeneration

    International Nuclear Information System (INIS)

    Valcour, H.

    1989-01-01

    Triple-membrane water treatment systems are comprised of ultrafiltration units for pretreatment, electrodialysis reversal primary demineralizers, reverse osmosis secondary demineralizers, portable ion exchange unit polishing demineralizers, and ultraviolet sterilizers. The triple-membrane process is designed to provide an unprecedented degree of pretreatment to maximize efficiency, durability and reliability of the reverse osmosis, whilst reducing the required regeneration frequency of the ion exchange demineralizer by one to two orders of magnitude. (author)

  11. 36 CFR 1210.34 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... 1210.34 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS ADMINISTRATION GENERAL RULES... data, including date of disposal and sales price or the method used to determine current fair market... the following standards. For equipment with a current per unit fair market value of $5,000 or more...

  12. Report on equipment availability for the ten-year period, 1966--1975

    Energy Technology Data Exchange (ETDEWEB)

    1976-12-01

    This is an annual report of availability and outage statistics for electric power generating facilities operating in the United States. A list of utility organizations voluntarily participating in the EEI Equipment Availability Program in 1975 is located in Appendix F. All summary reports in this publication are for the 10-year period 1966-1975. Each reporting utility company has received reports on individual units for which data were submitted. Also, selected major equipment manufacturers receive copies of computer reports showing an analysis of the data for their equipment. Revised reporting instructions to incorporate Safety and Environmental Requirement Cause Codes were issued effective January 1, 1976. In addition, provisions were made for identifying major equipment manufactured outisde of the United States or under foreign license. Recognizing that an Annual Report contains only a limited amount of general outage data in selected categories, the Task Force has agreed to perform special analyses of the data bank if the cost of computer services is met by the requestor and if the required analysis conforms to some designated policy guidelines.

  13. Quality control of conventional diagnostic radiology equipment in Serbia and Montenegro

    International Nuclear Information System (INIS)

    Ciraj, O.; Kosutic, D.; Markovic, S.

    2003-01-01

    There are more than 1500 diagnostic X-ray tubes in service in Serbia and Montenegro. Diagnostic X-ray equipment is checked on annual basis. X-ray equipment Qc protocols have been adopted from several international standards and guidelines [1,2], which have been modified according our practice and measuring equipment. According our inventory, about one half of all installed units is used for conventional X-ray diagnostics, 10% are mobile units, 2% of all in units in operation are mammographic devices an another 2% are computed tomography units. In addition there are about 600 dental X-ray units, which is 36% of all units. It is worth mentioning that almost 30 % of all installed units have single-phase generators, another 25% are tree phase (six and twelve pulse) generators and nearly 9% are high frequency units. Majority of units was installed more than 25 years ago. The Quality Control (QC) in radiography is a central part of QA programme, which deals with equipment maintenance and monitoring. QA in diagnostic radiology is a mean of maintaining standards in imaging and working towards minimizing patient and staff doses. As a part of QA programme in diagnostic radiology, the performance characteristics of 96 conventional X-ray units were measured in six months period during 2003. The diagnostic units were located in hospitals all over the country. They represent 25% of the total conventional diagnostic units of the country. About one half of measured X-ray units were new-installed. QC program has positive effect on X-ray equipment performance in a period of a few years. It is essential to perform QC tests for all installed X-ray units at least on annual basis. This would lead to production of consistent X-ray images, with minimal retake rate and hence, will contribute to decreasing of the patient dose. Patient doses are determined by multitude factors which interact in very complicated manner. It is very important to perform real patient dose measurements in

  14. Valorization procedure of x-ray equipment in the mammography equipment

    International Nuclear Information System (INIS)

    Ruiz, M. A.; Ordonez, J.; Antolin, E.; Andres, J. C. de; Gonzalez, I.; Arranz, L.; Sastre, J. M.; Ferrer, N.

    2006-01-01

    The Ramon y Cajal Hospital mammography service has three X-rays units, two of them with high resolution computed radiography (CR) system and one with flat-panel (FP)-based full-field digital mammography system. Periodic control dose tests in patients have shown lower glandular dose levels (DGM) than references provided by European Protocol for de Quality Control of de Physical and Technical Aspects of Mammography Screening. In this work, we have tried to establish an easy method for DGM calculation which is representative of the three equipment results. For this aim, we have defined an index which is measured along the time like a reference point. This index is defined as the relation between the blind test punctuations of a standard phantom image given by at least three radiologists in the Unit, and the average DGM values obtained in 20 patients in each Unit (using random thickness and random mama composition). (Author)

  15. Overhaul of the heat exchanger in JRR-3

    International Nuclear Information System (INIS)

    Ouchi, Yasuhiro; Kawamata, Satoshi; Taguchi, Yuji; Kamiishi, Eigo; Koda, Nobuyuki

    2013-01-01

    In JRR-3, heat exchangers are installed in the cooling system equipment to remove the heat generated in the nuclear reactor, For the heat exchangers, overhaul inspection based on the JRR-3 reactor facility maintenance plan, as well as the inspection and maintenance based on reactor facility security provisions and JRR-3 operation guidelines are systematically conducted. Considering the results of overhaul inspection, the second overhaul inspection was applied to the primary coolant heat exchanger. The thinning of heat transfer tubes is within judgment standards with little effects of aging, which verified their soundness. From the fact that the effects of corrosion have been confirmed on the inside of the water chamber, repair work through overlay welding or the like is planned in the next overhaul. As for heavy water heat exchanger and the spent fuel pool water heat exchanger, it is planned to conduct the second overhaul inspection in FY2013 to confirm their soundness. (A.O.)

  16. 31 CFR 360.48 - Restrictions on reissue; denominational exchange.

    Science.gov (United States)

    2010-07-01

    ...; denominational exchange. 360.48 Section 360.48 Money and Finance: Treasury Regulations Relating to Money and... GOVERNING DEFINITIVE UNITED STATES SAVINGS BONDS, SERIES I Reissue and Denominational Exchange § 360.48 Restrictions on reissue; denominational exchange. Reissue is not permitted solely to change denominations. ...

  17. Leader-member exchange theory and research : accomplishments and future challenges

    NARCIS (Netherlands)

    Breukelen, van W.; Schyns, B.; Blanc, Le P.M.

    2006-01-01

    In the Leader-Member Exchange (LMX) theory of leadership, the quality of the exchange relationship between a leader and a particular member of a work unit, team or organization is the basic unit of analysis (dyad). In this article, we try to answer the question whether research on the various

  18. Adventitious X-radiation from high voltage equipment

    International Nuclear Information System (INIS)

    Martin, E.B.M.

    1979-01-01

    The monograph is concerned with hazards of unwanted x-rays from sources such as television receivers, high voltage equipment, radar transmitters, switchgear and electron beam apparatus for welding, evaporation, analysis and microscopy. Chapters are included on units, production of x radiation, biological effects, protection standards, radiation monitoring, shielding and control of access, medical and dosimetric supervision and types of equipment. A bibliography of 92 references and other cited literature is included. (U.K.)

  19. A Modified Entropy Generation Number for Heat Exchangers

    Institute of Scientific and Technical Information of China (English)

    1996-01-01

    This paper demonstrates the difference between the entropy generation number method proposed by Bejian and the method of entropy generation per unit amount of heat transferred in analyzing the ther-modynamic performance of heat exchangers,points out the reason for leading to the above difference.A modified entropy generation number for evaluating the irreversibility of heat exchangers is proposed which is in consistent with the entropy generation per unit amount of heat transferred in entropy generation analysis.The entropy generated by friction is also investigated.Results show that when the entropy generated by friction in heat exchangers in taken into account,there is a minimum total entropy generation number while the NTU and the ratio of heat capacity rates vary.The existence of this minimum is the prerequisite of heat exchanger optimization.

  20. Optimal stochastic coordinated scheduling of proton exchange membrane fuel cell-combined heat and power, wind and photovoltaic units in micro grids considering hydrogen storage

    International Nuclear Information System (INIS)

    Bornapour, Mosayeb; Hooshmand, Rahmat-Allah; Khodabakhshian, Amin; Parastegari, Moein

    2017-01-01

    Highlights: •Stochastic model is proposed for coordinated scheduling of renewable energy sources. •The effect of combined heat and power is considered. •Hydrogen storage is considered for fuel cells. •Maximizing profits of micro grid is considered as objective function. •Considering the uncertainties of problem lead to profit increasing. -- Abstract: Nowadays, renewable energy sources and combined heat and power units are extremely used in micro grids, so it is necessary to schedule these units to improve the performance of the system. In this regard, a stochastic model is proposed in this paper to schedule proton exchange membrane fuel cell-combined heat and power, wind turbines, and photovoltaic units coordinately in a micro grid while considering hydrogen storage. Hydrogen storage strategy is considered for the operation of proton exchange membrane fuel cell-combined heat and power units. To consider stochastic generation of renewable energy source units in this paper, a scenario-based method is used. In this method, the uncertainties of electrical market price, the wind speed, and solar irradiance are considered. This stochastic scheduling problem is a mixed integer- nonlinear programming which considers the proposed objective function and variables of coordinated scheduling of PEMFC-CHP, wind turbines and photovoltaic units. It also considers hydrogen storage strategy and converts it to a mixed integer nonlinear problem. In this study a modified firefly algorithm is used to solve the problem. This method is examined on modified 33-bus distributed network as a MG for its performance.

  1. New tensioning equipment saves time at Browns Ferry

    International Nuclear Information System (INIS)

    Wagner, P.

    1996-01-01

    Improved reactor vessel tensioning technology has proved very successful at TVA's Browns Ferry station. The new equipment was used during unit 2's autumn 1994 outage and will be used there at the next outage, scheduled for March 1996. It will be deployed at unit 3, currently in restart mode. (author)

  2. An investigation of hydrogen storage methods for fuel cell operation with man-portable equipment

    Energy Technology Data Exchange (ETDEWEB)

    Browning, D [Defence Evaluation and Research Agency, Haslar (United Kingdom); Jones, P [Defence Evaluation and Research Agency, Haslar (United Kingdom); Packer, K [Defence Evaluation and Research Agency, Haslar (United Kingdom)

    1997-03-01

    Air breathing proton exchange membrane fuel cells (PEMFC) are being considered as a power source for man-portable equipment, such as army radios. In addition to the weight and volume of the fuel cell itself, the device producing hydrogen with which to fuel the cell is also of crucial importance. This paper describes a number of hydrogen storage methods and discusses their applicability to man-portable equipment. (orig.)

  3. EQuIP-ped for Success

    Science.gov (United States)

    Ewing, Molly

    2015-01-01

    The Educators Evaluating the Quality of Instructional Products (EQuIP) Rubric for science is a new tool for science educators that provides criteria by which to examine the alignment and overall quality of lessons and units with respect to the "Next Generation Science Standards" ("NGSS"). The rubric criteria are divided into…

  4. Eddy current inspection on heat exchanger tubes - problems and limitations

    International Nuclear Information System (INIS)

    Ilham Mukriz; Zainal Abidin Mohamed; Hairul Hasmoni Khairul Anuar; Mohd Salleh; Mahmood Dollah

    2005-01-01

    This paper focus on problems associated to eddy current inspection of heat exchanger tubes. A brief review on heat exchanger design and operation is presented. Eddy current technique in identifying inhomogeneity in tested tubes is discussed, highlighting its limitation in distinguishing between real pit type defects and other mundane anomalies. The limitation of the eddy current probe and equipment pertinent to the inspection are identified and areas of improvement are discussed. (Author)

  5. Regulation EM-GT-7. Quality control of the radiography equipment

    International Nuclear Information System (INIS)

    2015-01-01

    The purpose of this document is to provide practical guidance of technical procedures for carrying out quality control in X-ray equipment. This guide is applicable to general purpose radiography equipment, although some of the procedures may be applied to other types of diagnostic imaging equipment. The tests described require the appointed instrumentation and some of these can be implemented in the radiodiagnostic given the simplicity of them and others require special equipment and can be performed by external specialized groups to these units.

  6. Prophylactic and thermovision measurements of electric machines and equipment

    International Nuclear Information System (INIS)

    Jedlicka, R.; Brestovansky, L.

    1996-01-01

    High-voltage measurements of generators, unit and service transformers and some significant motor drives used at a nuclear power plant are described in this paper. Thermovision measurements of electric machines and distribution systems are dealt with in the second part of the paper. Power electric equipment represent one of the most significant components of a nuclear power plant. Turbine mechanical energy is converted into the electrical energy within these equipment. Power generated by generators is transformed by transformers so that it can achieve appropriate parameters for both the transmission over the distribution system and the power plant service power supply. The service power supply switchboards and cables provide supply to motors and other consumers necessary for the nuclear power plant technological process. The whole complex of equipment has to be maintained in good technical conditions. It is necessary to make thermovision and prophylactic measurements to identify and verify the electric equipment technical condition. The mentioned measurements warn the operation staff in advance against both gradual deterioration of power connection contact resistances, i.e. power connections overheating, and the machine insulation systems condition deterioration. The operation staff try to prevent the electric equipment operation accidents by early removing the detected failures, thus, improving the nuclear safety. In order to provide the above-mentioned activities a special prophylactic measurement group was established at the NPP Bohunice in 1983. The group specialists make following types of measurements. 1. Prophylactic measurements of electric machines. Prophylactics of 220 MW generators and 6 MW service power generators; Prophylactics of both unit and service transformers and VHV bushings; Prophylactics of major 6 kV motor drives. 2. Thermovision measurements of current connections. Measurements enumarated in paragraph 1 are made on disconnected electric

  7. DEVELOPMENT OF OPERATING DRIVE SYSTEMS IN ENGINEERING EQUIPMENT

    Directory of Open Access Journals (Sweden)

    A. A. Kotlobai

    2015-01-01

    Full Text Available Engineering machines being in operational service with military units of  engineer troops are fit to their purpose and their application is relevant in modern conditions. Maintenance of operating conditions in engineering equipment which was produced earlier by the USSR enterprises is considered as a rather complicated task due to lack of spare parts because their production has been discontinued.One of the approaches used for maintenance of engineering equipment combat capabilities is modernization of operating drive systems that presupposes replacement of mechanical systems in working element drives by hydrostatic drives which are realized while using modern element base. Usage of hydraulic units in drive systems being in mass production for replacement of mechanical systems manufactured earlier in small batches makes it possible to reduce labour inputs for maintenance and repair of machines. The paper presents some possibilities for development of operating drive systems in engineering equipment. The proposed approach is given through an example of  engineering obstacle-clearing vehicle (IMR-2M and excavation machines (MDK-3 and MDK-2M.Application of a hydraulic drive in working elements of the excavation machines permits to withdraw from cardan  shafts, a gear box, a rotary gear and an overload clutch. A hydraulic motor of the cutter and thrower drive is mounted  on a working element gearbox. While executing modernization of hydraulic systems in excavation machines a pump unit has been proposed for the cutter and thrower drive which consists of a controlled pump and a system for automatic maintenance of the pump operational parameters. While developing the operating drive systems in engineering equipment in accordance with the proposed requirements it is possible to simplify drive systems of working elements and  ensure reliable machinery operation in the units of engineer troops. 

  8. Methodology and measures for preventing unacceptable flow-accelerated corrosion thinning of pipelines and equipment of NPP power generating units

    Science.gov (United States)

    Tomarov, G. V.; Shipkov, A. A.; Lovchev, V. N.; Gutsev, D. F.

    2016-10-01

    Problems of metal flow-accelerated corrosion (FAC) in the pipelines and equipment of the condensate- feeding and wet-steam paths of NPP power-generating units (PGU) are examined. Goals, objectives, and main principles of the methodology for the implementation of an integrated program of AO Concern Rosenergoatom for the prevention of unacceptable FAC thinning and for increasing operational flow-accelerated corrosion resistance of NPP EaP are worded (further the Program). A role is determined and potentialities are shown for the use of Russian software packages in the evaluation and prediction of FAC rate upon solving practical problems for the timely detection of unacceptable FAC thinning in the elements of pipelines and equipment (EaP) of the secondary circuit of NPP PGU. Information is given concerning the structure, properties, and functions of the software systems for plant personnel support in the monitoring and planning of the inservice inspection of FAC thinning elements of pipelines and equipment of the secondary circuit of NPP PGUs, which are created and implemented at some Russian NPPs equipped with VVER-1000, VVER-440, and BN-600 reactors. It is noted that one of the most important practical results of software packages for supporting NPP personnel concerning the issue of flow-accelerated corrosion consists in revealing elements under a hazard of intense local FAC thinning. Examples are given for successful practice at some Russian NPP concerning the use of software systems for supporting the personnel in early detection of secondary-circuit pipeline elements with FAC thinning close to an unacceptable level. Intermediate results of working on the Program are presented and new tasks set in 2012 as a part of the updated program are denoted. The prospects of the developed methods and tools in the scope of the Program measures at the stages of design and construction of NPP PGU are discussed. The main directions of the work on solving the problems of flow

  9. Chapter 5. Essential equipment, pharmaceuticals and supplies. Recommendations and standard operating procedures for intensive care unit and hospital preparations for an influenza epidemic or mass disaster

    NARCIS (Netherlands)

    Sprung, Charles L.; Kesecioglu, Jozef; Christian, Michael D.; Camargo, Ruben; Ceraso, Daniel; Azoulay, Elie; Duguet, Alexandre; Guery, Benoit; Reinhart, Konrad; Adini, Bruria; Barlavie, Yaron; Benin-Goren, Odeda; Cohen, Robert; Klein, Motti; Leoniv, Yuval; Margalit, Gila; Rubinovitch, Bina; Sonnenblick, Moshe; Steinberg, Avraham; Weissman, Charles; Wolff, Donna; de Jong, Menno; Moreno, Rui; An, Youzhong; Du, Bin; Joynt, Gavin M.; Colvin, John; Loo, Shi; Richards, Guy; Artigas, Antonio; Pugin, Jerome; Amundson, Dennis; Devereaux, Asha; Beigel, John; Danis, Marion; Farmer, Chris; Hick, John L.; Maki, Dennis; Masur, Henry; Rubinson, Lewis; Sandrock, Christian; Talmor, Daniel; Truog, Robert; Zimmerman, Janice; Brett, Steve; Montgomery, Hugh; Rhodes, Andrew; Sanderson, Frances; Taylor, Bruce

    2010-01-01

    To provide recommendations and standard operating procedures for intensive care unit and hospital preparations for an influenza pandemic or mass disaster with a specific focus on essential equipment, pharmaceuticals and supplies. Based on a literature review and expert opinion, a Delphi process was

  10. An Evaluation System for Foodservice Equipment

    Science.gov (United States)

    1985-10-01

    of the machine, as eggs , pancakes, etc. cannot be cooked oo a grooved surface. A grooved suriaca will be tilted towards tha grease trough for...Refrigerator Specialty Units PREPARATION EQUIPMENT Burger Forming Machine Electric Meatball Machine breading Machine Crepe Machine Breaded/Sifter

  11. Equipment for the handling of thorium materials

    International Nuclear Information System (INIS)

    Heisler, S.W. Jr.; Mihalovich, G.S.

    1988-01-01

    The Feed Materials Production Center (FMPC) is the United States Department of Energy's storage facility for thorium. FMPC thorium handling and overpacking projects ensure the continued safe handling and storage of the thorium inventory until final disposition of the materials is determined and implemented. The handling and overpacking of the thorium materials requires the design of a system that utilizes remote handling and overpacking equipment not currently utilized at the FMPC in the handling of uranium materials. The use of remote equipment significantly reduces radiation exposure to personnel during the handling and overpacking efforts. The design system combines existing technologies from the nuclear industry, the materials processing and handling industry and the mining industry. The designed system consists of a modified fork lift truck for the transport of thorium containers, automated equipment for material identification and inventory control, and remote handling and overpacking equipment for material identification and inventory control, and remote handling and overpacking equipment for repackaging of the thorium materials

  12. APPLICATION FEATURES OF SPATIAL CONDUCTOMETRY SENSORS IN MODELLING OF COOLANT FLOW MIXING IN NUCLEAR POWER UNIT EQUIPMENT

    Directory of Open Access Journals (Sweden)

    A. A. Barinov

    2016-01-01

    Full Text Available Coolant flow mixing processes with different temperatures and concentrations of diluted additives widely known in nuclear power units operation. In some cases these processes make essential impact on the resource and behavior of the nuclear unit during transient and emergency situations. The aim of the study was creation of measurement system and test facility to carry out basic tests and to embed spatial conductometry method in investigation practice of turbulent coolant flows. In the course of investigation measurement system with sensors and experimental facility was designed, several first tests were carried out. A special attention was dedicated to calibration and clarification of conductometry sensor application methodologies in studies of turbulent flow characteristics. Investigations involved method of electrically contrast tracer jet with concurrent flow in closed channel of round crosssection. The measurements include both averaged and unsteady realizations of measurement signal. Experimental data processing shows good agreement with other tests acquired from another measurement systems based on different physical principles. Calibration functions were acquired, methodical basis of spatial conductometry measurement system application was created. Gathered experience of spatial sensor application made it possible to formulate the principles of further investigation that involve large-scale models of nuclear unit equipment. Spatial wire-mesh sensors proved to be a perspective type of eddy resolving measurement devices.

  13. HAPO Plant and capital equipment budget for FY 1966 and revision of budget for FY 1965 equipment not related to construction projects

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, J.E.

    1964-05-12

    This document is divided into: byproduct horizontal control rod system (5 reactors); high-speed scanning-effluent temperature monitoring system (KE reactor); improved reactor gas system (100-KE & KW); safety circuit system modifications (5 reactors); alternate process hot die sizing, 313 Building 300 Area; button line equipment (234-5 Building); in-tank waste solidification (3rd unit); and misc. minor equipment projects.

  14. Design and construction of the Portable Industrial X-Ray Equipment

    International Nuclear Information System (INIS)

    Nguyen Phuc; Nguyen Van Si; Le Tien Quan; Trinh Anh Tuan; Nguyen Manh Hung; Trinh Dinh Tuong

    2011-01-01

    The main purposes of the project are the supporting to design and construction of the Portable Industrial X-Ray Equipment; with the accuracy ±2% of Output High Voltage 200 kV and Tube current 5 mA. The Equipment is composed of control unit, X-ray generator, and power cable, connection cable. X-ray generator is assembling construction X-ray tube, H.V transformer together with gas insulation (SF6) are sealed up in aluminum bucked cabinet, fan and heat-sink are mounted in the end of X-ray generator as cooling, SF6 is a gas electrical performance to H.V. Alarm lamp is used to warn, flashing, show generating X-ray. Control unit is box construction. Four printed circuit boards (PCB) and electronic device are mounted in it. All operating buttons switches and displays are equipped on the panel. We have completed to design and construct the Portable Industrial X-Ray Equipment; and have tested the electronic parameters of all test points and the main parameters of equipment (the accuracy ±2% of Output High Voltage 200 kV and Tube current 5 mA). We also have successful used the Portable Industrial X-Ray Equipment to evaluate the welds in industry. (author)

  15. Life extension of MAPS-2 by replacement of boiler hairpin type heat exchangers

    International Nuclear Information System (INIS)

    Tripathi, J.C.; Rastogi, S.K.; Rastogi, A.K.

    2006-01-01

    The steam generating equipment in MAPS-1 and 2 are Hairpin type comprises of eight boiler assemblies arranged in two banks of four boilers each. Each hairpin type heat exchangers consist of 195 Monel-400 tubes of 12.7 mm OD x 1.24 mm WT. One boiler assembly consists of eleven inverted U type heat exchangers (called hairpin type heat exchangers) mounted in parallel on inlet and outlet heavy water manifolds and connected to steam drum through individual short riser. Heavy water flows through these tubes where as feed water enters the shell at the bottom of one leg called pre-heat leg. After commissioning of MAPS-2 in 1985, five hairpins of MAPS-2 developed leak during the course of operation by the year 1999. Absence of physical access for health assessment of steam generator tube and lack of provision for tube sheet cleaning to remove the deposits on feed water side had caused pile and resulted in tube failures by under deposit pitting corrosion. All the 88 hairpins of MAPS-2 were replaced to extend the plant life when MAPS-2 was taken out of grid for En-masse Coolant Channel Replacement job (EMCCR) in the year 2001 - 03. The long shutdown of MAPS units for EMCCR was considered to be cost effective since unscheduled plant shut downs on account of tube leaks could be avoided. (author)

  16. Surf zone Exchange on a Rip Channeled Beach

    Science.gov (United States)

    Reniers, A.; Macmahan, J.

    2008-12-01

    The dispersion and surf zone exchange of GPS-equipped surface drifters observed during the Rip Current EXperiment (RCEX) is examined with help of Lagrangian Coherent Structures (LCSs). LCSs allow for the detection of transport barriers in unsteady flows and are typically applied to shelf-scale circulation systems. Here LCSs are specifically computed to detect the effects of surfzone-originated Very Low Frequency motions (VLFs) with O(10) minute time scale on the cross-shore exchange of floating material using numerical model calculations of the Lagrangian surface velocity at the wave group timescale. After verification with RCEX field observations, the model is run for a range of environmental conditions experienced during the field experiment to assess the effects of VLFs on the cross-shore surf zone exchange. Results are relevant for (but not restricted to) sediment and nutrient exchange, human health, water clarity, and swimmer safety.

  17. United States: Ukraine Technical Exchange II trip report

    International Nuclear Information System (INIS)

    Moak, D.J.; Wendling, M.A.

    1995-02-01

    May 15--21, 1994, the first technical conference was held at Hanford between Ukraine-Chornobyl, Westinghouse Hanford, and SAIC, to exchange technical information and experience gained in cleanup and stabilization of radioactive contamination at Hanford and Chornobyl. Protocol was signed for a second exchange and technology demonstration program in Kiev and near Chornobyl power plants. Technical Exchange No. 2 was held from August 28--September 9, 1994, with 3 focus areas: field demonstration of DOE-Hanford technologies and application to cleanup of contaminated lands resulting from 1986 Chornobyl accident; application of other US DOE-technologies; and observation/evaluation of Ukraine-developed technologies for potential application in USA. Three radiological mapping systems were demonstrated near Chornobyl: man-carried Ultrasonic Ranging and Data System, a mobile radiological data system, and NOMAD field gamma spectroscopy system. The Ukraine-Chornobyl team hosted technical presentations, discussions and field trips for 4.5 days, providing insight on the Chornobyl problem and allowing the US team to present overviews on DOE technologies that may be applicable to the Chornobyl situation. It is concluded that Ukrainian scientists have tremendous talent and expended considerable energy in attempting to tackle such a problem, but economic and cultural conditions with Ukraine have prevented them from acquiring the resources to implement basic aspects of characterization and remediation activities. Most of their publications are in Russian only. Their translation, plus resources to carry out proposals for bench scale and field demonstration projects, could benefit the DOE complex and other nuclear programs. The considerable cultural and economic change occurring in Ukraine, is providing opportunities for private industries to assist in the changes and for DOE, others to apply cleanup technologies, and it is essential that close institutional relations be established

  18. Numerical Simulation and Analysis on Liquid Nitrogen Spray Heat Exchanger

    OpenAIRE

    Wenjing Ding; Weiwei Shan; Zijuan; Wang; Chao He

    2017-01-01

    Liquid spray heat exchanger is the critical equipment of temperature regulating system by gaseous nitrogen which realizes the environment temperature in the range of -180 ℃~+180 ℃. Liquid nitrogen is atomized into smaller liquid drops through liquid nitrogen sprayer and then contacts with gaseous nitrogen to be cooled. By adjusting the pressure of liquid nitrogen and gaseous nitrogen, the flowrate of liquid nitrogen is changed to realize the required outlet temperature of heat exchanger. The ...

  19. Performance Measurement of Mining Equipments by Utilizing OEE

    Directory of Open Access Journals (Sweden)

    Sermin Elevli

    2010-10-01

    Full Text Available Over the past century, open pit mines have steadily increased their production rate by using larger equipments which requireintensive capital investment. Low commodity prices have forced companies to decrease their unit cost by improving productivity. Oneway to improve productivity is to utilize equipment as effectively as possible. Therefore, the accurate estimation of equipmenteffectiveness is very important so that it can be increased. Overall Equipment Effectiveness (OEE is a well-known measurementmethod, which combines availability, performance and quality, for the evaluation of equipment effectiveness in manufacturing industry.However, there isn’t any study in literature about how to use this metric for mining equipments such as shovel, truck, drilling machineetc. This paper will discuss the application of OEE to measure effectiveness of mining equipment. It identifies causes of time losses forshovel and truck operations and introduces procedure to record time losses. The procedure to estimate OEE of shovels and trucks hasalso been presented via numerical example.

  20. Design of common heat exchanger network for batch processes

    International Nuclear Information System (INIS)

    Anastasovski, Aleksandar

    2014-01-01

    Heat integration of energy streams is very important for the efficient energy recovery in production systems. Pinch technology is a very useful tool for heat integration and maximizing energy efficiency. Creating of heat exchangers network as a common solution for systems in batch mode that will be applicable in all existing time slices is very difficult. This paper suggests a new methodology for design of common heat exchanger network for batch processes. Heat exchanger network designs were created for all determined repeatable and non-repeatable time periods – time slices. They are the basis for creating the common heat exchanger network. The common heat exchanger network as solution, satisfies all heat-transfer needs for each time period and for every existing combination of selected streams in the production process. This methodology use split of some heat exchangers into two or more heat exchange units or heat exchange zones. The reason for that is the multipurpose use of heat exchangers between different pairs of streams in different time periods. Splitting of large heat exchangers would maximize the total heat transfer usage of heat exchange units. Final solution contains heat exchangers with the minimum heat load as well as the minimum need of heat transfer area. The solution is applicable for all determined time periods and all existing stream combinations. - Highlights: •Methodology for design of energy efficient systems in batch processes. •Common Heat Exchanger Network solution based on designs with Pinch technology. •Multipurpose use of heat exchangers in batch processes

  1. Maintenance and fabrication of nuclear electronic equipment

    International Nuclear Information System (INIS)

    Hong, Seok Boong; Chung, Chong Eun; Hwang, In Koo; Koo, In Soo; Park, Bum; Kim, Soo Hee; Lee, Seong Joo; Kim, Min Seok; Choi, Wha Lim

    2011-12-01

    - process equipment at PIEF, Chemical Analysis Team and RWFTF have been calibrated. - The electronic equipment and radiation equipment at RWTF and PIEF have been prepared. - Development and installation of integrated RMS software for Hanaro Cold Neutron Laboratory Building(CNLB) RMS, and development and performance upgrade of a portal monitor for CNLB. - Performance test of the Hardware/Software of digital unit controller has been performed, and functional upgrade of the Hardware/Software of stimulator for SMART MMIS performance test facility has also been performed. - A controller of high voltage power supply for a small electron beam generator and a controller for razer pinning and a remote monitoring apparatus of cathode power supply for a 0.2 Mev. small electron beam generator have been designed and fabricated. - Database construction for effective maintenance for the process equipment and radiation instruments are designed and constructed

  2. Ion exchange in the 1980's in South Africa

    International Nuclear Information System (INIS)

    Giddey, T.B.S.

    1981-01-01

    In South Africa ion exchange plants have been modified into very sophisticated plants. This article looks at the development of- and application of resins and their manufacturing. At first it looks into how the equipment side has developed and changed in the last twenty years. High purity water production, desalination, waste water treatment and other applications of ion exchange in mineral recovery, like uranium, gold and base metals, and in chemical areas, like sugar processing, catalysis, tartaric acid and soda ash, are also discussed. Klipfontein Organic Products is setting up a plant to manufacture the whole range of ion exchange resins and thus to make SA needs to be independent of overseas suppliers of resin

  3. Thermoacoustic refrigerators and engines comprising cascading stirling thermodynamic units

    Science.gov (United States)

    Backhaus, Scott; Swift, Greg

    2013-06-25

    The present invention includes a thermoacoustic assembly and method for improved efficiency. The assembly has a first stage Stirling thermal unit comprising a main ambient heat exchanger, a regenerator and at least one additional heat exchanger. The first stage Stirling thermal unit is serially coupled to a first end of a quarter wavelength long coupling tube. A second stage Stirling thermal unit comprising a main ambient heat exchanger, a regenerator, and at least one additional heat exchanger, is serially coupled to a second end of the quarter wavelength long coupling tube.

  4. Changes in distribution of bone densitometry equipment from 1996 to 2006 in Japan.

    Science.gov (United States)

    Yamauchi, Hirose; Fukunaga, Masao; Nishikawa, Akira; Orimo, Hajime

    2010-01-01

    Many types of bone densitometry equipment are available in Japan, but the numbers of such machines and the numbers of institutions that offer bone densitometry have not been clarified. We analyzed the data from annual surveys conducted by the Japan Osteoporosis Foundation from 1996 to 2006, and we obtained the following results on the use of densitometry equipment: (1) In 1996 there were 6,687 units of bone densitometry equipment in 6,483 institutions in Japan; in 2006 there were 16,371 units in 15,020 institutions. (2) In 2006, of the types of institutions with bone densitometry equipment, the number of clinics was the highest, followed in order by general hospitals, other types of institutions, screening institutions and university hospitals. Rates of increase in the installation of equipment in clinics and other types of institutions were high during the 11-year period from 1996. (3) From 1996 to 2006 the region of interest most frequently used for bone densitometry was the radius. However, during the 11-year period, the proportion of radial densitometry equipment in all institutions with bone densitometry equipment decreased, whereas the proportion of calcaneal densitometry equipment increased. (4) The number of dual-energy X-ray absorptiometry (DXA) units was the highest from 1996 to 2006. However, the proportion of DXA machines in all institutions with bone densitometry equipment decreased over the 11-year period, whereas the proportion of quantitative ultrasound (QUS) machines increased. (5) In 2006, bone densitometry equipment was available in 118 institutions per million Japanese people. Central DXA (spine/hip) equipment was available in 15 per million, radial DXA equipment in 63 per million, and calcaneal QUS equipment in 44 per million. (6) In 2006, among those places with bone densitometry equipment, 46% of university hospitals, 14% of general hospitals, 12% of screening institutions, 5% of clinics, and 6% of other types of institutions possessed more

  5. Model Adoption Exchange Payment System: Executive Summary.

    Science.gov (United States)

    Ambrosino, Robert J.

    This executive summary provides a brief description of the Model Adoption Exchange Payment System (MAEPS), a unique payment system aimed at improving the delivery of adoption exchange services throughout the United States. Following a brief introductory overview, MAEPS is described in terms of (1) its six components (registration, listing,…

  6. Behavior of copper corrosion products in water loops of heat-exchange units

    International Nuclear Information System (INIS)

    Zarembo, V.I.; Kritskii, V.G.; Slobodov, A.A.; Puchkov, L.V.

    1989-01-01

    This communication is dedicated to an examination of copper corrosion products (CP) in the conditions of real aqueous-chemical regime (ACR) parameters. The deposition of these CP in steam-generating zones (up to 85% of their total amount) stimulate local types of corrosion. The solubility in Cu CP (Cu 2 O, CuO, Cu(OH) 2 )-water (H 2 O)-gas (H 2 , O 2 )-conditioning additives (HCl, KOH) systems was determined by computer modeling according to the minimum Gibbs energy criterion on the basis of selected and matched thermodynamic constants for various chemical forms of copper under standard conditions. As a result of the authors' calculations they obtained the solubilities in water of CuO, Cu 2 O and Cu(OH) 2 when changing the dosage of active gases from 0 to 10 -2 mole/kg of water, of acid or equal to that of saturated vapor of pure water. Thus, they were able to monitor the behavior of copper CP in conditions modeling those of real ACR in operating heat exchange units, including in conditions deviating from the standard

  7. Relationship Between Site Disturbance and Forest Harvesting Equipment Traffic

    Science.gov (United States)

    Tim McDonald; Emily Carter; Steve Taylor; John Tobert

    1998-01-01

    A study was done to evaluate the use of global positioning systems (GPS) to track the position of forest harvesting equipment and use the information to assess site impacts. GPS units were attached to tree-length harvesting machinery in two clearcuts (1 feller-buncher, 2 skidders). Position of the equipment was recorded at 2-second intervals throughout the harvest of...

  8. Heat Transfer and Entropy Generation Analysis of an Intermediate Heat Exchanger in ADS

    Science.gov (United States)

    Wang, Yongwei; Huai, Xiulan

    2018-04-01

    The intermediate heat exchanger for enhancement heat transfer is the important equipment in the usage of nuclear energy. In the present work, heat transfer and entropy generation of an intermediate heat exchanger (IHX) in the accelerator driven subcritical system (ADS) are investigated experimentally. The variation of entropy generation number with performance parameters of the IHX is analyzed, and effects of inlet conditions of the IHX on entropy generation number and heat transfer are discussed. Compared with the results at two working conditions of the constant mass flow rates of liquid lead-bismuth eutectic (LBE) and helium gas, the total pumping power all tends to reduce with the decreasing entropy generation number, but the variations of the effectiveness, number of transfer units and thermal capacity rate ratio are inconsistent, and need to analyze respectively. With the increasing inlet mass flow rate or LBE inlet temperature, the entropy generation number increases and the heat transfer is enhanced, while the opposite trend occurs with the increasing helium gas inlet temperature. The further study is necessary for obtaining the optimized operation parameters of the IHX to minimize entropy generation and enhance heat transfer.

  9. A structured approach to heat exchanger network retrofit design

    NARCIS (Netherlands)

    Van Reisen, J.L.B.

    2008-01-01

    Process plants have high energy consumption. Much energy can be saved by a proper design of the heat exchanger network, which contains the main heat transferring equipment of the plant. Existing plants can often be made more energy-efficient by a retrofit: the (physical) modification of the

  10. System for remote routine monitoring of power equipment at TPP and NPP

    International Nuclear Information System (INIS)

    Kantsedalov, V.G.; Samojlenko, V.P.; Doroshenko, V.A.

    1988-01-01

    A system for remote routine monitoring of TPP and NPP pipeline metals is described. The principal functional unit of the system is the unit of remote routine methods and techniques for studying and monitoring the metal and properties. The system is equipped with 5 types of routine monitoring equipment: robots, remote aggregated complexes, periodical diagnostic monitors, other means of metal diagnostics (endoscopes, introscopes). All current information enters the unit for estimating and forecasting the service life of power unit, where it is compared with the standard indices of reliability, duravility and efficiency. The system considered permits to reduce significantly or minimize the scope of works on metal monitoring during overhauls, increase intermonitoring and interrepairing compaigns to 8 years

  11. Regulatory aspects of the enforcement policy applied to teletherapy equipment obsolescence (1995-2002)

    International Nuclear Information System (INIS)

    Truppa, Walter A.; Rey, Hugo L.; Rojas, Carlos A.

    2004-01-01

    The paper describes the way in which the Nuclear Regulatory Authority (ARN) has implemented an 'enforcement' policy for the services of radiotherapy that operated obsolete cobalt therapy units. Without doubt one of the greater advances has been the simulation and planning of the treatment, indispensable tools in a system of quality in radiotherapy where the equipment acquires a preponderant paper. In Argentina the distribution of equipment was inhomogeneous, and within it coexisted, as primary and unique units, great amount with a technology today already obsolete. The Nuclear Regulatory Authority (ARN) took a strong regulatory attitude directed to change or to retire many of the units, as its characteristics of design and antiquity did not fulfill the criteria of radiological security established in the norms (optimization of the dose, distances source to skin, yield in surface, adequate maintenance, etc.). On this matter a policy was applied to impose within suitable terms, the change of the obsolete equipment for this practice, particularly those distances source to skin minor than 80 cm. As result of the applied coercive measures at this moment, 28 equipment of cobalt therapy in advanced degree of obsolescence were retired by regulatory decision. Part of these equipment were replaced by their owners by more modern equipment whose operation adjusts to the requirements of the radiological security norm, whereas the majority was replaced by linear accelerators. At the moment there are 86 of cobalt therapy units and 52 accelerators operating in our country, against 104 and 32 respectively, that operated in 1995. (author)

  12. Chemical technologies and life management of Ukrainian NPPs

    International Nuclear Information System (INIS)

    Arkhipenko, A.V.; Barbashev, S.V.; Litvinskij, L.L.; Masko, A.N.

    2000-01-01

    Now 11 units with WWER-1000 reactors, 2 units with WWER-440 and 1 unit with RBMK-1000 are operated in Ukraine. State of chemical technologies of NPPs essentially influences on unit operating resource by the next ways: decreasing of corrosion intensity of equipment metal; decreasing of contamination on thermal exchanged surfaces of equipment; decreasing of amounts of radioactive waste. Improvement of these parameters can be achieved by the next measures: improvement of purification schemes for feed water of main systems; introduction of more effective water-chemical regimes (WCR); implementation of new methods and instruments of chemical monitoring for WCR; providing of without-scale regime of thermal-exchanged equipment operating by reactor division users through optimisation of the WCR of the NPP spray pool. (author)

  13. CEO's guide to world business costs : oil and gas equipment

    International Nuclear Information System (INIS)

    2004-01-01

    This paper presents the results of a detailed study of wellhead equipment manufacturing costs in 11 countries in North America, Europe and Asia-Pacific. According to the Economist Intelligence Unit (EIU), Canada has a 5 per cent cost advantage and will be the best country in the world to do business between 2004 to 2008 because of its foreign trade policies, high quality infrastructure and market opportunities within the North American marketplace. KPMG Consulting developed a web-based cost model that allows investors to examine the costs involved in setting up and operating a business in more than 120 cities in Canada, the United States, the United Kingdom, France, Germany, Italy, Iceland, Luxembourg, the Netherlands, Japan and Australia. According to the model, a comparison of annual costs for oil and gas wellhead equipment manufacturing was presented for the 11 countries with reference to revenues, costs, and profits before and after income tax. In addition, Canada's research and development (R and D) cost advantage compared to the United States was presented, with reference to tax credits, expenditures, salaries, contracts, capital equipment, volume-based tax credits, and research studies. This report also includes a brief summary of 3 oil and gas companies that came to Canada and prospered. tabs., figs

  14. Alert Exchange Process Protocol

    Science.gov (United States)

    Groen, Frank

    2015-01-01

    The National Aeronautics and Space Administration of the United States of America (NASA), and the European Space Agency (ESA), and the Japanese Aerospace Exploration Agency (JAXA), acknowledging that NASA, ESA and JAXA have a mutual interest in exchanging Alerts and Alert Status Lists to enhance the information base for each system participant while fortifying the general level of cooperation between the policy agreement subscribers, and each Party will exchange Alert listings on regular basis and detailed Alert information on a need to know basis to the extent permitted by law.

  15. Page THE ROLE OF SECURITIES AND EXCHANGE COMMISSION

    African Journals Online (AJOL)

    Fr. Ikenga

    Exchange Commission requires that important information concerning the issuer and the securities ... role of the Securities and Exchange Commission in regulating investments and securities ... relatively long periods for use by economic units with deficit funds. ..... (including bank account) of any person whose assets were.

  16. Thermodynamic analysis of a refrigeration cycle using regenerative heat exchanger - suction/liquid line

    Energy Technology Data Exchange (ETDEWEB)

    Tebchirani, Tarik Linhares; Matos, Rudmar Serafim [Pos graduate Programme in Mechanical Engineering (PGMEC), Universidade Federal do Parana, Curitiba, PR (Brazil)], e-mails: tarik@utfpr.edu.br, rudmar@demec.ufpr.br

    2010-07-01

    This paper presents results from thermodynamic comparison of a conventional compression cycle and a steam cycle that uses a heat exchanger countercurrent (liquid line/suction line) in an air conditioning system split. The main objective is to study the relationship between the COP and the mass variation of refrigerant to the effectiveness of the heat exchanger. The papers presented in the literature discuss the matter in a theoretical way, are summarized in tables of rare loss statements without specification of methods. The methodology of work is based on testing of an air conditioner operating conventionally and also with the heat exchanger for the determination of values and parameters of interest. The tests were performed in a thermal chamber with temperature controlled and equipped with a data acquisition system for reading and storage results. The refrigerant was R22. Besides making possible an assessment of the feasibility of cost-benefit thermodynamics, it is suggested a different method for installing the equipment type split. (author)

  17. Functional integration of digital radiologic equipment

    International Nuclear Information System (INIS)

    Agnifili, A.; DiStefano, G.; Salcito, G.; Passariello, R.

    1989-01-01

    This paper reports on a pilot project for the functional integration of digital radiologic equipment. Four different systems (a digital subtraction angiography unit, a DF unit, a computer radiography prototype, and a film digitizer) were connected with a link in an Ethernet LAN.ACR-NEMA standards were used to process the images of the different units in the same way. The central computer manages the long-term optical archive and the film laser printer. Some graphic workstations are connected to the picture archiving and communications system, which allows fast retrieval and processing of the images. Patients; data are acquired through the RIS and stored together with the images

  18. PROMSYS, Plant Equipment Maintenance and Inspection Scheduling

    International Nuclear Information System (INIS)

    Morgan, D.L.; Srite, B.E.

    1986-01-01

    1 - Description of problem or function: PROMSYS is a computer system designed to automate the scheduling of routine maintenance and inspection of plant equipment. This 'programmed maintenance' provides the detailed planning and accomplishment of lubrication, inspection, and similar repetitive maintenance activities which can be scheduled at specified predetermined intervals throughout the year. The equipment items included are the typical pumps, blowers, motors, compressors, automotive equipment, refrigeration units, filtering systems, machine shop equipment, cranes, elevators, motor-generator sets, and electrical switchgear found throughout industry, as well as cell ventilation, shielding, containment, and material handling equipment unique to nuclear research and development facilities. Four related programs are used to produce sorted schedule lists, delinquent work lists, and optional master lists. Five additional programs are used to create and maintain records of all scheduled and unscheduled maintenance history. 2 - Method of solution: Service specifications and frequency are established and stored. The computer program reviews schedules weekly and prints, on schedule cards, instructions for service that is due the following week. The basic output from the computer program comes in two forms: programmed-maintenance schedule cards and programmed-maintenance data sheets. The data sheets can be issued in numerical building, route, and location number sequence as equipment lists, grouped for work assigned to a particular foreman as the foreman's equipment list, or grouped by work charged to a particular work order as the work-order list. Data sheets grouped by equipment classification are called the equipment classification list

  19. Diamond wire cutting of heat exchangers

    International Nuclear Information System (INIS)

    Beckman, T.R.; Bjerler, J.

    1991-01-01

    With the change-out of equipment at nuclear power plants comes large quantities of low level contaminated metallic waste. Of particular concern are large heat exchangers, preheaters and steam generators. These bulky items consume huge volumes of burial space. The need for volume reduction and recycling of these metals has created new demands for 'how' to cut heat exchangers into useful sizes for decontamination, melting or compaction. This paper reviews the cutting solution provided by a diamond wire system, with particular regard for cutting of a Ringhals Preheater Bundle at Studsvik Nuclear in 1989. The background of diamond wire sawing is discussed and basic components of wire sawing are explained. Other examples of wire cutting decommissioned components are also given. (author)

  20. Resistance welding equipment manufacturing capability for exports

    Energy Technology Data Exchange (ETDEWEB)

    Sastry, V.S.; Raju, Y.S.; Somani, A.K.; Setty, D.S.; Rameswara Raw, A.; Hermantha Rao, G.V.S.; Jayaraj, R.N. [Nuclear Fuel Complex, Dept. of Atomic Energy, Hyderbad (India)

    2010-07-01

    Indian Pressurised Heavy Water Reactor (PHWR) fuel bundle is fully welded and is unique in its design. Appendage welding, end closure welding, and end plate welding is carried out using resistance welding technique. Out of many joining processes available, resistance-welding process is reliable, environment friendly and best suitable for mass production applications. Nuclear Fuel Complex (NFC), an industrial unit is established in Hyderabad, under the aegis of the Dept of Atomic Energy to manufacture fuel for Pressurised Heavy Water Reactors. From inception, NFC has given importance for self-reliance and indigenization with respect to manufacturing process and equipment. Sintering furnaces, centreless grinders, appendage-welding machines, end-closure welding equipment and end-plate welding equipments, which were initially imported, are either indigenized or designed and manufactured in house. NFC has designed, manufactured a new appendage-welding machine for manufacturing 37 element fuel bundles. Recently NFC has bagged an order from IAEA through international bidding for design, manufacture, supply, erection and commissioning of end-closure welding equipment. The paper gives in detail the salient features of these welding equipment. (author)

  1. Understanding cross-national trends in high-tech renewable power equipment exports to the United States

    International Nuclear Information System (INIS)

    Sawhney, Aparna; Kahn, Matthew E.

    2012-01-01

    We track US imports of advanced technology wind and solar power-generation equipment from a panel of countries during 1989–2010, and examine the determining factors including country size, sector-specific US FDI outflow, and domestic wind and solar power generation. Differentiating between the core high-tech and the balance of system equipment, we find US imports of both categories have grown at significantly higher rate from the relatively poorer countries, and particularly China and India. Larger countries are found to be exporting significantly more, and US FDI is found to play a significant positive role in the exports of high-tech equipment for the poor countries. For the core wind and solar high-tech equipment, we find domestic renewable power generation of the exporting countries also played a significant positive role. - Highlights: ► We track US imports of advanced technology wind and solar power-generation equipment. ► US imports of both categories have grown at significantly higher rate from China and India. ► US FDI is found to play a significant positive role in the exports of high-tech equipment.

  2. 76 FR 63974 - Self-Regulatory Organizations; Chicago Board Options Exchange, Incorporated; Notice of Filing and...

    Science.gov (United States)

    2011-10-14

    .... However, in the future, the Exchange may offer faster access at a higher gigabyte level, and may elect to charge a higher rate for such access (as the infrastructure and equipment involved would be costlier). To the extent the Exchange does offer faster access at a higher gigabyte level, and assesses a higher...

  3. Metallurgical investigation of cracking of the isolation valve downstream piping of regenerative heat exchanger at beaver valley unit 1 station

    International Nuclear Information System (INIS)

    Rao, G.V.

    1998-01-01

    A metallurgical investigation was conducted to establish the mechanism and cause of cracking in the regenerative heat exchanger piping at Beaver Valley Unit 1 PWR station in the USA. The investigation, which was centered on an eight inch long pipe section containing the cracking included surface examinations, metallographic and fractographic examinations, and chemistry evaluations. The results of the examinations showed that there were two types of pipe degradation mechanisms that affected the type 304 stainless schedule 40 piping. These consisted of localized corrosive attack on the OD surface due to the presence of chlorides, sulphates and phosphates, and transgranular stress corrosion cracking in the pipe wall due to the presence of chloride contaminants. The overall results of the investigation showed that the introduction of contaminants from external sources other than pipe insulation was the cause of heat exchanger pipe cracking. (author)

  4. Labelling of equipment dispensers.

    Science.gov (United States)

    Gray, D C

    1993-01-01

    A new labelling system for use on medical equipment dispensers is tested. This system uses one of the objects stored in each unit of the dispenser as the 'label', by attaching it to the front of the dispenser with tape. The new system was compared to conventional written labelling by timing subjects asked to select items from two dispensers. The new system was 27% quicker than the conventional system. Images Fig. 1 PMID:8110335

  5. Foreign Exchange Reserves: Bangladesh Perspective

    Directory of Open Access Journals (Sweden)

    Md Zahangir Alam

    2013-10-01

    Full Text Available This study is about foreign exchangereserves of Bangladesh. The mainpurpose of this study is to the influence of exchange rates on foreign exchangereserves to the Bangladesh context.  Both the primary and secondary data has been used inthis study. The primary data has been collected through a structuredquestionnaire from 50 respondents. The secondary data, namely Bangladeshforeign exchange reserves (FER, Bangladesh current account balance (CAB,Bangladesh capital andfinancial account balance (CFAB, and BDT/USD exchange rates (ER.  This study covers yearly data from July 01,1996 to June 30, 2005 and quarterly data from July 01, 2005 to June 30, 2012. Findingsof this study shows that out of the selected 16 factors affecting foreignexchange reserves, exchange rates occupy the first position, weighted averagescore (WAS being 4.56. Foreign exchange reserves (FER and current accountbalance (CAB have increased by 502.9087% and 1451.218%,whereas capital and financial account (CFAB has decreased by -649.024% on June30, 2012 compared to June 30, 1997. The influence of other factors heldconstant, as ER changes by 285.6894 units due to one unit change in FER, onaverage in the same direction which represents that ER has positive effect on theFER and this relationship is statistically significant.  62.1526 percentof the variation in FER is explained by ER. The outcomes of Breusch-Godfrey test (LM test, ARCHtest, and the Normality test are that there is a serial correlation among residuals, the variance of residuals is notconstant, and the residuals are not normally distributed.

  6. Portable Power And Digital-Communication Units

    Science.gov (United States)

    Levin, Richard R.; Henry, Paul K.; Rosenberg, Leigh S.

    1992-01-01

    Conceptual network of electronic-equipment modules provides electrical power and digital radio communications at multiple sites not served by cables. System includes central communication unit and portable units powered by solar photovoltaic arrays. Useful to serve equipment that must be set up quickly at remote sites or buildings that cannot be modified to provide cable connections.

  7. Energic, Exergic, Exergo‐economic investigation and optimization of auxiliary cooling system (ACS equipped with compression refrigerating system (CRS

    Directory of Open Access Journals (Sweden)

    Omid Karimi Sadaghiyani

    2017-09-01

    Full Text Available Heller main cooling tower as air-cooled heat exchanger is used in the combined cycle power plants (CCPP to reduce the temperature of condenser. In extreme summer heat, the efficiency of the cooling tower is reduced and it lessens performance of Steam Turbine Generation (STG unit of Combined Cycle Power Plant (CCPP. Thus, the auxiliary cooling system (ACS is equipped with compression refrigerating system (CRS. This auxiliary system is linked with the Heller main cooling tower and improves the performance of power plant. In other words, this auxiliary system increases the generated power of STG unit of CCPP by decreasing the temperature of returning water from cooling tower Therefore, in the first step, the mentioned auxiliary cooling system (ACS as a heat exchanger and compression refrigerating system (CRS have been designed via ASPEN HTFS and EES code respectively. In order to validate their results, these two systems have been built and theirs experimentally obtained data have been compared with ASPEN and EES results. There are good agreements between results. After that, exergic and exergo-economic analysis of designed systems have been carried out. Finally, the compression refrigerating system (CRS has been optimized via Genetic Algorithm (GA. Increasing in exergy efficiency (ε from 14.23% up to 36.12% and decreasing the total cost rate (ĊSystem from 378.2 ($/h to 308.2 ($/h are as results of multi-objective optimization.

  8. Combined Steady-State and Dynamic Heat Exchanger Experiment

    Science.gov (United States)

    Luyben, William L.; Tuzla, Kemal; Bader, Paul N.

    2009-01-01

    This paper describes a heat-transfer experiment that combines steady-state analysis and dynamic control. A process-water stream is circulated through two tube-in-shell heat exchangers in series. In the first, the process water is heated by steam. In the second, it is cooled by cooling water. The equipment is pilot-plant size: heat-transfer areas…

  9. Minimization of entropy production in separate and connected process units

    Energy Technology Data Exchange (ETDEWEB)

    Roesjorde, Audun

    2004-08-01

    The objective of this thesis was to further develop a methodology for minimizing the entropy production of single and connected chemical process units. When chemical process equipment is designed and operated at the lowest entropy production possible, the energy efficiency of the equipment is enhanced. We have found for single process units that the entropy production could be reduced with up to 20-40%, given the degrees of freedom in the optimization. In processes, our results indicated that even bigger reductions were possible. The states of minimum entropy production were studied and important painter's for obtaining significant reductions in the entropy production were identified. Both from sustain ability and economical viewpoints knowledge of energy efficient design and operation are important. In some of the systems we studied, nonequilibrium thermodynamics was used to model the entropy production. In Chapter 2, we gave a brief introduction to different industrial applications of nonequilibrium thermodynamics. The link between local transport phenomena and overall system description makes nonequilibrium thermodynamics a useful tool for understanding design of chemical process units. We developed the methodology of minimization of entropy production in several steps. First, we analyzed and optimized the entropy production of single units: Two alternative concepts of adiabatic distillation; diabatic and heat-integrated distillation, were analyzed and optimized in Chapter 3 to 5. In diabatic distillation, heat exchange is allowed along the column, and it is this feature that increases the energy efficiency of the distillation column. In Chapter 3, we found how a given area of heat transfer should be optimally distributed among the trays in a column separating a mixture of propylene and propane. The results showed that heat exchange was most important on the trays close to the re boiler and condenser. In Chapter 4 and 5, we studied how the entropy

  10. 48 CFR 945.505-11 - Records of transportation and installation costs of plant equipment.

    Science.gov (United States)

    2010-10-01

    ... and installation costs of plant equipment. 945.505-11 Section 945.505-11 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CONTRACT MANAGEMENT GOVERNMENT PROPERTY Management of Government... plant equipment. The requirements of FAR 45.505-11 apply to plant equipment having a unit cost of $1,000...

  11. Review of the experience obtained in the evaluation of vibrations and their effects on the structural integrity of heat exchangers

    International Nuclear Information System (INIS)

    Ghiselli, Alberto M.; Pastorini, Alberto; Kulichevsky Raul

    2000-01-01

    Flow induced vibrations may produce damage of shell-tube type heat exchangers, condensers and steam generators tubes. These vibrations could be produce by changes in the equipment operational condition or by a wrong evaluation during the design procedure. The typical results are tube damage by impact or fretting wear. This paper include a review of the flow-induced vibration mechanisms that affect shell-tube heat exchangers and some practical examples that show the results obtained evaluating this equipment. (author)

  12. Numerical simulation of flow field in shellside of heat exchanger in nuclear power plant

    International Nuclear Information System (INIS)

    Wang Xinliang; Qiu Jinrong; Gong Zili

    2010-01-01

    Heat exchanger is the important equipment of nuclear power plant. Numerical simulation can give the detail information inside the heat exchange, and has been an effective research method. The geometric structure of shell-and-tube heat exchanger is very complex and it is difficult to simulate the whole flow field presently. According to the structure characteristics of the heat exchanger, a periodic whole-section calculation model was presented. The numerical simulation of flow field in shellside of heat exchange of a nuclear power plant was done by using this model. The results of simulation show that heat transfer in the periodic section of the heat exchange is uniform, the heat transfer is enhanced by using baffles in heat exchange, and frictional resistance is primary from the effect of segmental baffles. (authors)

  13. Design of EPON far-end equipment based on FTTH

    Science.gov (United States)

    Feng, Xiancheng; Yun, Xiang

    2008-12-01

    Now, most favors fiber access is mainly the EPON fiber access system. Inheriting from the low cost of Ethernet, usability and bandwidth of optical network, EPON technology is one of the best technologies in fiber access and is adopted by the carriers all over the world widely. According to the scheme analysis to FTTH fan-end equipment, hardware design of ONU is proposed in this paper. The FTTH far-end equipment software design deference modulation design concept, it divides the software designment into 5 function modules: the module of low-layer driver, the module of system management, the module of master/slave communication, and the module of main/Standby switch and the module of command line. The software flow of the host computer is also analyzed. Finally, test is made for Ethernet service performance of FTTH far-end equipment, E1 service performance and the optical path protection switching, and so on. The results of test indicates that all the items are accordance with technical request of far-end ONU equipment and possess good quality and fully reach the requirement of telecommunication level equipment. The far-end equipment of FTTH divides into several parts based on the function: the control module, the exchange module, the UNI interface module, the ONU module, the EPON interface module, the network management debugging module, the voice processing module, the circuit simulation module, the CATV module. In the downstream direction, under the protect condition, we design 2 optical modules. The system can set one group optical module working and another group optical module closure when it is initialized. When the optical fiber line is cut off, the LOS warning comes out. It will cause MUX to replace another group optical module, simultaneously will reset module 3701/3711 and will make it again test the distance, and will give the plug board MPC850 report through the GPIO port. During normal mode, the downstream optical signal is transformed into the

  14. Liquid Metal Fast Breeder Reactor plant maintenance and equipment design

    International Nuclear Information System (INIS)

    Swannack, D.L.

    1982-01-01

    This paper provides a summary of maintenance equipment considerations and actual plant handling experiences from operation of a sodium-cooled reactor, the Fast Flux Test Facility (FFTF). Equipment areas relating to design, repair techniques, in-cell handling, logistics and facility services are discussed. Plant design must make provisions for handling and replacement of components within containment or allow for transport to an ex-containment area for repair. The modular cask assemblies and transporter systems developed for FFTF can service major plant components as well as smaller units. The plant and equipment designs for the Clinch River Breeder Reactor (CRBR) plant have been patterned after successful FFTF equipment

  15. Use value, exchange value, and resource scarcity

    International Nuclear Information System (INIS)

    Stern, D.I.

    1999-01-01

    The literature on natural resource scarcity indicators is reviewed. Scarcity indicators can be classified by what is being measured: value of the resource stock or value of extracted resource commodities; whose value is considered: social vs. private scarcity; and by the mode of valuation considered: exchange value and use value. Prices and rents are common measures of exchange value or indicators of ''exchange scarcity'' and unit costs can be seen as use value indicators or indicators of u se scarcity . The major aim of this paper is to demonstrate the links between productivity indicators such as unit costs and the classical concept of use value. The two classes of indicator relate to John Commons' discussions of scarcity and efficiency, and a marginal vs. a non-marginal approach to value and scarcity. The classical use value concept also has wider relevance for issues of valuation in energy, resource, and environmental policy. (author)

  16. Oil-field equipment in Romania. Export trade information

    International Nuclear Information System (INIS)

    Tinis, R.

    1991-09-01

    The Industry Sector Analyses (I.S.A.) for oil field equipment contains statistical and narrative information on projected market demand, end-users, receptivity of Romanian consumers to U.S. products, the competitive situation - Romanian production, total import market, U.S. market position, foreign competition, and competitive factors, and market access - Romanian tariffs, non-tariff barriers, standards, taxes and distribution channels. The I.S.A. provides the United States industry with meaningful information regarding the Romanian market for oil field equipment

  17. Test procedure for anion exchange testing with Argonne 10-L solutions

    International Nuclear Information System (INIS)

    Compton, J.A.

    1995-01-01

    Four anion exchange resins will be tested to confirm that they will sorb and release plutonium from/to the appropriate solutions in the presence of other cations. Certain cations need to be removed from the test solutions to minimize adverse behavior in other processing equipment. The ion exchange resins will be tested using old laboratory solutions from Argonne National Laboratory; results will be compared to results from other similar processes for application to all plutonium solutions stored in the Plutonium Finishing Plant

  18. Feedwater heater performance evaluation using the heat exchanger workstation

    International Nuclear Information System (INIS)

    Ranganathan, K.M.; Singh, G.P.; Tsou, J.L.

    1995-01-01

    A Heat Exchanger Workstation (HEW) has been developed to monitor the condition of heat exchanging equipment power plants. HEW enables engineers to analyze thermal performance and failure events for power plant feedwater heaters. The software provides tools for heat balance calculation and performance analysis. It also contains an expert system that enables performance enhancement. The Operation and Maintenance (O ampersand M) reference module on CD-ROM for HEW will be available by the end of 1995. Future developments of HEW would result in Condenser Expert System (CONES) and Balance of Plant Expert System (BOPES). HEW consists of five tightly integrated applications: A Database system for heat exchanger data storage, a Diagrammer system for creating plant heat exchanger schematics and data display, a Performance Analyst system for analyzing and predicting heat exchanger performance, a Performance Advisor expert system for expertise on improving heat exchanger performance and a Water Calculator system for computing properties of steam and water. In this paper an analysis of a feedwater heater which has been off-line is used to demonstrate how HEW can analyze the performance of the feedwater heater train and provide an economic justification for either replacing or repairing the feedwater heater

  19. Ethical Leadership, Leader-Member Exchange and Feedback Seeking: A Double-Moderated Mediation Model of Emotional Intelligence and Work-Unit Structure

    Science.gov (United States)

    Qian, Jing; Wang, Bin; Han, Zhuo; Song, Baihe

    2017-01-01

    This research elucidates the role of ethical leadership in employee feedback seeking by examining how and when ethical leadership may exert a positive influence on feedback seeking. Using matched reports from 64 supervisors and 265 of their immediate employees from a hotel group located in a major city in China, we proposed and tested a moderated mediation model that examines leader-member exchange (LMX) as the mediator and emotional intelligence as well as work-unit structure as double moderators in the relationships between ethical leadership and followers’ feedback-seeking behavior from supervisors and coworkers. Our findings indicated that (1) LMX mediated the positive relationship between ethical leadership and feedback seeking from both ethical leaders and coworkers, and (2) emotional intelligence and work-unit structure served as joint moderators on the mediated positive relationship in such a way that the relationship was strongest when the emotional intelligence was high and work-unit structure was more of an organic structure rather than a mechanistic structure. PMID:28744251

  20. Imaging of endogenous exchangeable proton signals in the human brain using frequency labeled exchange transfer imaging.

    Science.gov (United States)

    Yadav, Nirbhay N; Jones, Craig K; Hua, Jun; Xu, Jiadi; van Zijl, Peter C M

    2013-04-01

    To image endogenous exchangeable proton signals in the human brain using a recently reported method called frequency labeled exchange transfer (FLEX) MRI. As opposed to labeling exchangeable protons using saturation (i.e., chemical exchange saturation transfer, or CEST), FLEX labels exchangeable protons with their chemical shift evolution. The use of short high-power frequency pulses allows more efficient labeling of rapidly exchanging protons, while time domain acquisition allows removal of contamination from semi-solid magnetization transfer effects. FLEX-based exchangeable proton signals were detected in human brain over the 1-5 ppm frequency range from water. Conventional magnetization transfer contrast and the bulk water signal did not interfere in the FLEX spectrum. The information content of these signals differed from in vivo CEST data in that the average exchange rate of these signals was 350-400 s(-1) , much faster than the amide signal usually detected using direct saturation (∼30 s(-1) ). Similarly, fast exchanging protons could be detected in egg white in the same frequency range where amide and amine protons of mobile proteins and peptides are known to resonate. FLEX MRI in the human brain preferentially detects more rapidly exchanging amide/amine protons compared to traditional CEST experiments, thereby changing the information content of the exchangeable proton spectrum. This has the potential to open up different types of endogenous applications as well as more easy detection of rapidly exchanging protons in diaCEST agents or fast exchanging units such as water molecules in paracest agents without interference of conventional magnetization transfer contrast. Copyright © 2013 Wiley Periodicals, Inc.

  1. Effects of culture and age on the perceived exchange of social support resources.

    Science.gov (United States)

    VonDras, Dean D; Pouliot, Gregory S; Malcore, Sylvia A; Iwahashi, Shigetoshi

    2008-01-01

    This research explores the perceived exchange of social support resources of young, midlife, and older adults in the United States and Japan, and how perceptions of exchange may moderate attributions of control, difficulty, and success in attaining important life-goals. A survey was administered to participants in the United States and Japan who ranged in age from 17 to 70 years. Results suggested culture and age to influence the designation of important life-goals, and to interactively moderate the perceived exchange of social support resources in the interpersonal contexts of family and business associates and co-workers. Furthermore, relationships between the perceived exchange of social support and perceptions of control and success in achieving life-goals indicated different intracultural effects. Overall, these findings suggest nuances in the perceived exchange of social support and social cognitions that reflect the cultural orientations of young, midlife and older adults in the United States and Japan. A culturally grounded model of social support is proposed and discussed.

  2. Safety systems I/C equipment reliability analyses of the Kozloduy NPP units 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Halev, G; Christov, N [Risk Engineering Ltd., Sofia (Bulgaria)

    1996-12-31

    The purpose of the analysis is to assess the safety systems I/C equipment reliability. The assessment includes: quantification of the safety systems unavailability due to component failures; definition of the minimal cut sets leading to the analysed safety systems failure; quantification of the I/C equipment importance measures of the dominant contribution components. The safety systems I/C equipment reliability has been analysed using PSAPACK (a code for probabilistic safety assessment). Fault trees for the following safety systems of the Kozloduy-3 and Kozloduy-4 reactors have been constructed: neutron flow control equipment, reactor protection system, main coolant pumps, pressurizer safety valves `Sempell`, steam dump systems, spray system, low pressure injection system, emergency feeding water system, essential service water system. THree separate reports have been issued containing the performed analyses and results. 1 ref.

  3. Thermal response testing of precast pile heat exchangers

    DEFF Research Database (Denmark)

    Pagola, Maria Alberdi; Poulsen, Søren Erbs; Jensen, Rasmus Lund

    The report is organized as follows: first, the concept of TRT is explained. Second, the test sites are described. Third, the field work is presented and a summary of the future work regarding the methodology to treat the data from the tests is provided. Finally, further documentation...... of the fieldwork, the pile heat exchangers and the TRT equipment is extended in diverse appendices....

  4. The use of adaptive equipment following total knee replacement

    OpenAIRE

    McNaught, Jamie; Paul, Lorna

    2015-01-01

    Introduction: This study evaluates the need for adaptive equipment following total knee replacement. There are no recent studies to guide occupational therapists in the optimum time adaptive equipment is required following total knee replacement.\\ud \\ud Method: A non-experimental, concurrent mixed methods approach was used. The study population was patients attending for total knee replacement at a large general hospital. Outcome measures were the Oxford Knee Score, the United Kingdom Functio...

  5. Analysis of Serbian Military Riverine Units Capability for Participation in the United Nations Peacekeeping Operations

    Directory of Open Access Journals (Sweden)

    Slobodan Radojevic

    2017-06-01

    Full Text Available This paper analyses required personnel, training capacities and equipment for participation in the United Nations peacekeeping operations with the riverine elements. In order to meet necessary capabilities for engagement in United Nations peacekeeping operations, Serbian military riverine units have to be compatible with the issued UN requirements. Serbian Armed Forces have the potential to reach such requirements with the River Flotilla as a pivot for the participation in UN missions. Serbian Military Academy adopted and developed educational and training program in accordance with the provisions and recommendations of the IMO conventions and IMO model courses. Serbian Military Academy has opportunities for education and training military riverine units for participation in the United Nations peacekeeping operations. Moreover, Serbia has Multinational Operations Training Center and Peacekeeping Operations Center certified to provide selection, training, equipping and preparations of individuals and units to the United Nations multinational operations.

  6. Semiautomatic exchanger of samples for carry out neutron activation analysis; Intercambiador semiautomatico de muestras para realizar analisis por activacion neutronica

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar H, F.; Quintana C, G. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Torres R, C. E.; Mejia J, J. O., E-mail: fortunato.aguilar@inin.gob.mx [Instituto Tecnologico de Toluca, Av. Tecnologico s/n, Ex-Rancho La Virgen, Metepec, Estado de Mexico (Mexico)

    2015-09-15

    In this paper the design methodology and implementation of a semiautomatic exchanger of samples for the Analysis Laboratory by Neutron Activation of the Reactor department is presented. Taking into account the antecedents, the necessities of improvement are described, as well as the equipment that previously contained the Laboratory. The project of the semiautomatic exchanger of samples was developed at Instituto Nacional de Investigaciones Nucleares, with its own technology to increase independence from commercial equipment. Each element of the semiautomatic exchanger of samples is described both in the design phase as construction. The achieved results are positive and encouraging for the fulfillment of the proposed objective that is to increase the capacity of the Laboratory. (Author)

  7. Tl dosimetry around equipment s for dental radiography

    International Nuclear Information System (INIS)

    Medrano, E.; Robles G, M. A.; Vega C, H. R.; Letechipia de L, C.; Hernandez D, V. M.

    2014-08-01

    The ambient dose equivalent around X-rays units used in dentistry has been measured. The radiation that escapes of the tail stock of the X-rays equipment was also measured, and the dose in the surfaces of a polyethylene spherical mannequin and other of water, used to represent the patient and the operator, respectively. The study was realized with thermoluminescent dosimeters of the type 100. The operation conditions of the X-rays units were varied when the ambient dose equivalent was measured. In the other measurements the equipment s were operated to 70 k Vp and 8 m A. In the ambient dose equivalent was found asymmetry, likewise the due dose to the radiation that escapes of one of tail stocks was also asymmetric. The dose values in the mannequins went minors to the recommended reference values. (Author)

  8. After-hours Power Status of Office Equipment and Inventory of Miscellaneous Plug-load Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Margaret J.; Busch, John F.

    2004-01-22

    This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of ''miscellaneous'' plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers. This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from twelve commercial buildings in California, Georgia, and Pennsylvania: two health care buildings, two large offices (> 500 employees each), three medium offices (50-500 employees), four education buildings, and one ''small office'' that is actually an aggregate of five small businesses. Two buildings are in the San Francisco Bay area of California, five are in

  9. Annual report of the group for maintenance of electronic equipment

    International Nuclear Information System (INIS)

    Popovic, B.

    1965-01-01

    Maintenance and repair of the RA reactor control and safety systems were uniformly distributed during the whole year and were done according to the annual plan. A series of repairs of he electronic equipment as well as exchange of electronic components and elec tonic tubes. The testing and calibration of control and protection circuits were done regularly according to the needs and operation state of the reactor and according to the instructions. Inspections, repairs and reconstructions well as operating characteristics of individual elements as well as complete electronic circuits during 1965 have shown da the systems of control and safety are still in good condition. Somewhat higher number of failures due to aging of electronic tubes is a regular consequence of equipment and instrumentation aging [sr

  10. The Analysis of the System of special water purification of Beloyarskaya Nuclear Power Plant unit BN-800

    Science.gov (United States)

    Valtseva, A. I.; Bibik, I. S.

    2017-11-01

    This article discusses how the latest system of special water purification KPF-30, designed specifically for the fourth power unit of Beloyarskaya nuclear power plant, which has a number of advantages over other water purification systems as chemical-physical and technical-economic, environmental, and other industrial indicators. The scheme covered in this article systems of special water purification involves the use of a hydrocyclone at the preliminary stage of water treatment, as a worthy alternative to ion-exchange filters, which can significantly reduce the volume of toxic waste. The world community implements the project of closing the nuclear fuel cycle, there is a need to improve the reliability of the equipment for safe processes and development of critical and supercritical parameters in the nuclear industry. Essentially, on operated NPP units, the only factor that can cost-effectively optimize to improve the reliability of equipment is the water chemistry. System KPF30 meets the principles and criteria of ecological safety, demonstrating the justification for reagent less method of water treatment on the main stages, in which no formation of toxic wastes, leading to irreversible consequences of environmental pollution and helps to conserve water.

  11. 3 CFR - Waiver of Reimbursement Under the United Nations Participation Act to Support the United Nations...

    Science.gov (United States)

    2010-01-01

    ... Participation Act to Support the United Nations/African Union Mission in Darfur Presidential Documents Other... the United Nations Participation Act to Support the United Nations/African Union Mission in Darfur... the United Nations/African Union Mission in Darfur to support the airlift of equipment for...

  12. Design and construction rules for electrical equipments of nuclear islands. 3. ed.

    International Nuclear Information System (INIS)

    1993-01-01

    The French design and construction for electrical equipments of nuclear islands (RCC-E) deals with equipments of which the failure may have consequences on the safety of persons or appreciable effects on the availability of the power plant. This book presents the rules concerning (1) qualification procedure, (2) the design of functional units, (3) the installation (environmental conditions, protection rules), (4) the constituent elements of equipments, (5) the control and testing methods

  13. Position measuring device

    International Nuclear Information System (INIS)

    Maeda, Kazuyuki; Takahashi, Shuichi; Maruyama, Mayumi

    1998-01-01

    The present invention provides a device capable of measuring accurate position and distance easily even at places where operator can not easily access, such as cell facilities for vitrifying radioactive wastes. Referring to a case of the vitrifying cell, an objective equipment settled in the cell is photographed by a photographing device. The image is stored in a position measuring device by way of an image input device. After several years, when the objective equipment is exchanged, a new objective equipment is photographed by a photographing device. The image is also stored in the position measuring device. The position measuring device compares the data of both of the images on the basis of pixel unit. Based on the image of the equipment before the exchange as a reference, extent of the displacement of the installation position of the equipment on the image after the exchange caused by installation error and manufacturing error is determined to decide the position of the equipment after exchange relative to the equipment before exchange. (I.S.)

  14. Cleaning Schedule Operations in Heat Exchanger Networks

    Directory of Open Access Journals (Sweden)

    Huda Hairul

    2018-01-01

    Full Text Available Heat exchanger networks have been known to be the essential parts in the chemical industries. Unfortunately, since the performance of heat exchanger can be decreasing in transferring the heat from hot stream into cold stream due to fouling, then cleaning the heat exchanger is needed to restore its initial performance periodically. A process of heating crude oil in a refinery plant was used as a case study. As many as eleven heat exchangers were used to heat crude oil before it was heated by a furnace to the temperature required to the crude unit distillation column. The purpose of this study is to determine the cleaning schedule of heat exchanger on the heat exchanger networks due to the decrease of the overall heat transfer coefficient by various percentage of the design value. A close study on the process of heat exchanger cleaning schedule in heat exchanger networks using the method of decreasing overall heat transfer coefficient as target. The result showed that the higher the fouling value the more often the heat exchanger is cleaned because the overall heat transfer coefficient decreases quickly.

  15. Effects of Culture and Age on the Perceived Exchange of Social Support Resources

    Science.gov (United States)

    Vondras, Dean D.; Pouliot, Gregory S.; Malcore, Sylvia A.; Iwahashi, Shigetoshi

    2008-01-01

    This research explores the perceived exchange of social support resources of young, midlife, and older adults in the United States and Japan, and how perceptions of exchange may moderate attributions of control, difficulty, and success in attaining important life-goals. A survey was administered to participants in the United States and Japan who…

  16. Selection of equipment for equipment qualification

    International Nuclear Information System (INIS)

    Torr, K.G.

    1989-01-01

    This report describes the methodology applied in selecting equipment in the special safety systems for equipment qualification in the CANDU 600 MW nuclear generating stations at Gentilly 2 and Point Lepreau. Included is an explanation of the selection procedure adopted and the rationale behind the criteria used in identifying the equipment. The equipment items on the list have been grouped into three priority categories as a planning aid to AECB staff for a review of the qualification status of the special safety systems

  17. Neonatal resuscitation equipment: A hidden risk for our babies?

    Science.gov (United States)

    Winckworth, Lucinda C; McLaren, Emma; Lingeswaran, Arvin; Kelsey, Michael

    2016-05-01

    Neonatal infections carry a heavy burden of morbidity and mortality. Poor practice can result in unintentional colonisation of medical equipment with potentially pathogenic organisms. This study will determine the prevalence and type of bacterial contamination on exposed neonatal resuscitation equipment in different clinical settings and explore simple measures to reduce contamination risk. A survey determined the rates of resuscitation equipment usage. All environmentally exposed items were identified on resuscitaires hospital-wide and swabbed for bacterial contamination. A new cleaning and storage policy was implemented and the prevalence of environmentally exposed equipment re-measured post-intervention. Resuscitation equipment was used in 28% of neonatal deliveries. Bacterial colony forming units were present on 44% of the 236 exposed equipment pieces swabbed. There was no significant difference in contamination rates between equipment types. Coagulase negative staphylococcus was the most prevalent species (59 pieces, 25%) followed by Escherichia coli and Enterobacter cloacae (20 pieces, 9% each). Opened items stored inside plastic remained sterile, whilst those in low-use areas had significantly less contamination than those in high-use areas (22% vs. 51%, P reducing microbial colonisation opportunities. © 2016 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  18. New excitation equipment for 220 MW generators in Kozloduy NPP

    International Nuclear Information System (INIS)

    Tomerlin, D.

    2001-01-01

    Rehabilitation on the excitation equipment for Generator 5, Reactor Unit 3, in Kozloduy NPP was completed in November 2000. ABB's Static Excitation System based on UNITROL 5000 technology has been chosen by the Bulgarian National Utility and Kozloduy NPP to substitute the original Russian excitation system equipment with electro-magnetic voltage regulators. The substitution is in a rehabilitation package of four excitation system equipment for Generator 5 and 6 of Reactor Unit 3 and Generator 7 and 8 of Reactor Unit 4 after a short overview of the original excitation system this paper describes the new Static Excitation System UNITROL 5000 including configuration with block diagram, its main features and merits such as modes of operation, limiter, special control functions and diagnostic facilities. Furthermore, new facilities, which are implemented in UNITROL 5000, such as dynamic current distribution among the thyristors working in parallel as well as the start-up from the residual magnetism are mentioned. Special functions including a so-called free-running mode of operation and automatic change over sequence from new excitation system to the stand-by excitation system, which is DC exciter machine, are described. Some records of the transient responses performed during the commissioning and a photograph of a manufactured system are provided. (author)

  19. Face recognition in securing optical telecom network equipment

    International Nuclear Information System (INIS)

    Ali, N.M.

    2015-01-01

    In this paper, face recognition is used with a microcontroller based hardware module to secure the telecommunication equipments like ONU (optical network units) or any other telecommunication equipment. The face recognition classifier value optimization adaption is deployed and in this scheme by increasing or decreasing the number of images in the database will automatically generate and adopt the classifier value for recognition of known and unknown persons. On recognizing and unknown persons. On recognizing an unknown person, the hardware module will send an SMS to the concerned security personnel for security preventive measures. (author)

  20. Study of heat exchange in cooling systems of heat-stressed structures

    Science.gov (United States)

    Vikulin, A. V.; Yaroslavtsev, N. L.; Zemlyanaya, V. A.

    2017-01-01

    Increasing working parameters of the cycle of gas-turbine engines, complicating design of gas-turbine plants, as well as growing aerodynamic, thermal, static, and dynamic loads, necessitate the development of promising cooling systems for heat-stressed structures. This work is devoted to an experimental study of heat exchange in ducts equipped with systems of inclined and cross walls (fins). It has been found that an increase in the Reynolds number Re from 3000 to 20000 leads to a decrease in the heat exchange, which is characterized by the relative Nusselt number overline{Nu}, by 19-30% at the angle of inclination of the walls φ = 0, 40°, 50°, and 90° if the length of the walls x w is comparable to the spacing b s and by 12-15% at φ = 30° and 90° if x w ≫ b s. If cross walls are used in cooling ducts, the length of the walls x w plays the governing role; an increase in this characteristic from 1.22 × 10-3 to 3.14 × 10-3 m leads to an increase in the intensity of heat exchange by 30-40% and to a decrease in the capacity of the entire system of the walls. It has been shown that, on surfaces with wavy fins, the intensity of heat exchange is closest to that determined in the models under study. For example, values of the Colborne criterion StPr2/3 for ducts equipped with wavy fins and for the models under study differ only slightly (by 2-20% depending on the value of the angle φ). However, the difference for surfaces with short plate fins and ducts equipped with inclined walls is high (30-40%). This is due to the design features of these surfaces and to the severe effect of the inlet portion on heat exchange, since the surfaces are characterized by a higher ratio of the duct length to the hydraulic diameter L/d h at small fin thicknesses ((0.1-0.15) × 10-3 m). The experimental results can be used in developing designs of nozzle and rotor blades of high-temperature gas turbines in gas-turbine engines and plants.

  1. Policies and Procedures for Foreign Exchange Agencies. First Edition.

    Science.gov (United States)

    Hartman, Donald D.

    The guide details the policy of the Jefferson County (Alabama) Board of Education policy concerning international exchange of students (travel both to and from United States) in elementary and secondary grades. The first section specifies the standards by which the county will evaluate all international exchange agencies concerning structure,…

  2. Proceedings of the European Symposium on Pressure Equipment - ESOPE 2007; Actes des Journees d'Etudes Europeennes Equipements sous Pression - ESOPE 2007

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    Every three years, and since thirty years, the AFIAP organizes a symposium where the experts and actors working in the field of pressure equipments, whether fixed or transportable, can meet and exchange on all developments related to their activity. What was at first called the 'National Congress on the technology of pressure components', and later the 'Study Days on pressure components', became since 2001 the 'European Symposium on Pressure Equipment' (ESOPE), so marking an opening to the European and International fields in a context marked by the application of the European Directives applicable to these equipments. The 2001 symposium was more particularly dedicated to the application of the directives harmonizing the construction of equipments, and the 2004 symposium was more particularly centred on the management of equipments in operation. For the ESOPE 2007 Symposium, the organizing committee wished to resume these two subjects under the aspects of the safety, the competitiveness, as well as the innovation. The plenary session of the last day will be completely dedicated to these subjects and will include a Panel discussion, where National and European authorities, representatives of manufacturers and users, as well as experts engaged in developments and new projects will express their views. These exchanges will also permit to answer the questions expressed by the participants. Every symposium has thus a main orientation, but shall also be the place of exchanges on the different subjects wished by the profession. The traditional technical sessions are consequently maintained: - Sessions on Design and Materials, - Sessions on Fabrication, - Sessions on Fitness for Service, and a special session dedicated to the National, European and International Codes is added, the afternoon of the first day. The plenary Opening session is also devoted to this last subject with lectures on the evolutions of European regulations, the

  3. Unsolved problems in applying U.S. regulatory guides to control system equipment

    International Nuclear Information System (INIS)

    Stade, R.E.

    1978-01-01

    Two current problems encountered when designing control systems to the United States Regulatory Guide requirements are discussed. They are: 1) Level of surge voltages that should be specified when procuring solid state control and instrumentation systems and equipment. 2) The approach to be used qualifying equipment that must meet the aging requirements. (author)

  4. Method for the positioning of pipes in a heat exchanger

    International Nuclear Information System (INIS)

    1983-01-01

    The invention relates to a method for positioning pipes in a heat exchanger. The grating that supports the pipes of the heat exchanger may be equipped with projections in the passages that also support the pipes. Such projections may, however, obstruct the positioning of the pipes in the grating. The purpose of the invention is to bypass this problem by applying receding projections that move outward when a wedge is put in the grating and thereupon turned round in such a way that the pipes can freely be positioned. Thereupon, the wedge is turned back and the projections will resume their positions. (Auth.)

  5. New Czechoslovak detector of leaking condenser tubes usable in both shutdown and reduced output operation of power unit

    International Nuclear Information System (INIS)

    Matal, O.; Klinga, J.; Varvarovsky, F.; Zachar, J.; Fratric, D.

    1986-01-01

    The main reason for penetration of undesirable admixtures from cooling water in the condensate is the inleakage of steam turbine condensers. Briefly assessed are the means and methods of detecting and locating condenser leaks used in the world and in power facilities in Czechoslovakia. Equipment was developed based on measuring the difference between the pressure in a temporarily closed condenser tube and ambient pressure, for leak testing of condenser tubes during operation and during shutdown of WWER-440 units. Two types of the equipment were tested in practice. Type VUEZ-PHN 85P meets the requirements of objective leak tests and those of leak location in condenser tubes and of leak detection in tube expansion in the tube plates of WWER-440 unit condensers, this as concerns sensitivity, the objectivity of results, the cost of tests, and minimal losses of power during the test. Type VUEZ-PHN 85P can be used for leak location in all tube type heat exchangers with access to tube outlets in which under- or overpressure can be achieved in the space between the tubes relative to ambient pressure during the test. (Z.M.) 5 figs., 4 tabs., 11 refs

  6. Analysis of operating reliability of WWER-1000 unit

    International Nuclear Information System (INIS)

    Bortlik, J.

    1985-01-01

    The nuclear power unit was divided into 33 technological units. Input data for reliability analysis were surveys of operating results obtained from the IAEA information system and certain indexes of the reliability of technological equipment determined using the Bayes formula. The missing reliability data for technological equipment were used from the basic variant. The fault tree of the WWER-1000 unit was determined for the peak event defined as the impossibility of reaching 100%, 75% and 50% of rated power. The period was observed of the nuclear power plant operation with reduced output owing to defect and the respective time needed for a repair of the equipment. The calculation of the availability of the WWER-1000 unit was made for different variant situations. Certain indexes of the operating reliability of the WWER-1000 unit which are the result of a detailed reliability analysis are tabulated for selected variants. (E.S.)

  7. EFFICIENCY OF FOREIGN EXCHANGE MARKETS: A DEVELOPING COUNTRY PERSPECTIVE

    OpenAIRE

    Guneratne Banda Wickremasinghe

    2004-01-01

    This study tests weak and semi-strong form efficiency of the foreign exchange market in Sri Lanka using six bilateral foreign exchange rates during the recent float. Weak-form efficiency is examined using unit root tests while semi-strong form efficiency is tested using co- integration and Granger causality tests and variance decomposition analysis. Results indicate that the Sri Lankan foreign exchange market is consistent with the weak -form of the Efficient Market Hypothesis. However, the r...

  8. Peer-to-Peer Consultations: Ancillary Services Peer Exchange with India: Experience from South Africa, Europe & the United States (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2014-05-01

    In support of national and subnational decision makers, the 21st Century Power Partnership regularly works with country partners to organize peer-to-peer consultations on critical issues. In March 2014, 21CPP collaborated with the Regulatory Assistance Project - India to host two peer-to-peer exchanges among experts from India, South Africa, Europe, and the United States to discuss the provision of ancillary services, particularly in the context of added variability and uncertainty from renewable energy. This factsheet provides a high level summary of the peer-to-peer consultation.

  9. The influence of heat exchanger design on the synthesis of heat exchanger networks

    Directory of Open Access Journals (Sweden)

    Liporace F.S.

    2000-01-01

    Full Text Available Heat exchanger network (HEN synthesis has been traditionally performed without accounting for a more detailed unit design, which is important since the final HEN may require unfeasible units. Recently, publications on this matter have appeared, as well as softwares that simultaneously perform synthesis and units design. However, these publications do not clearly show the influence of the new added features on the final HEN. Hence, this work aims at showing that units' design can strongly affect the final HEN. Improvements on heat transfer area and total annual cost estimations, which influence the HEN structural evolution, are the main responsible for that. It is also shown the influence of some design bounds settings, which can indicate an unfeasible unit design and, therefore, the need for a new match search or the maintenance of a loop. An example reported in the literature is used to illustrate the discussion.

  10. Proceedings of the European Symposium on Pressure Equipment - ESOPE 2004

    International Nuclear Information System (INIS)

    2004-01-01

    The symposium on Pressure Equipment Technology, organised every three years by the AFIAP (Association Francaise des Ingenieurs en Appareils a Pression), for the second time is organised at the European level. It is the 'European Symposium on Pressure Equipment, ESOPE 2004'. This symposium is placed under the patronage of the Minister of Industry. The central theme of ESOPE 2001 has been the European Directives for Fixed Equipment (PED) and for Transportable Equipment (TPED). ESOPE 2004 will be a state on the application of these Directives after 3 years of use. The first plenary session will made the comparison of some National codes with EN13445 standard and of the evolution of the Asme code. But the principal theme of the second plenary session and the panel, where European experts will answer to your questions, will be on 'Pressure equipment life management'. It therefore seems important to incorporate this subject into the agenda of this symposium in order to allow widespread dialogue between the industrial members concerned. Our association, AFIAP, has the advantage of regrouping all the industrial partners concerned, from the end user and the administrative body responsible for equipment safety, to the pressure equipment fabricator and his materials suppliers, also including those bodies responsible for design, inspection and certification. To improve availability of equipment and reduce production costs the most efficient way is the development of technology. It is essential to improve competitiveness of European companies. Research is necessary, but the results must be available to everyone, including small and medium-sized industries. ESOPE 2004 has 3 technical sessions in parallel, which will be followed, by many fruitful exchanges of experience: - design/materials - fabrication/welding/inspection - fitness for service. You will find on a CD-Rom all the contributions which have been presented. (authors)

  11. Leak detection in a high-pressure heat exchanger system in a refinery using radiotracer technique

    International Nuclear Information System (INIS)

    Samantray, J.S.; Sunil Goswami; Sharma, V.K.; Jayashree Biswal; Pant, H.J.

    2014-01-01

    A radiotracer investigation was carried out in a diesel hydrotreater (DHDT) unit in a refinery for leak detection in a breech-lock heat exchanger system. The main objectives of the study were to identify the leaking heat exchanger in a system with six heat exchangers and estimate the leak rate. Bromine-82 as dibromobiphenyl was selected and used as radiotracer for the investigation. The radiotracer was instantaneously injected into the suction end of the feed pump line to the heat exchanger of the DHDT unit. The movement of the tracer was measured at strategically selected locations using NaI(Tl) scintillation detectors. Based upon the results of the radiotracer investigation, it was found that out of six heat exchangers, exchanger E-1F was leaking. (author)

  12. Injecting drug use in prison: prevalence and implications for needle exchange policy.

    Science.gov (United States)

    Wright, Nat M J; Tompkins, Charlotte N E; Farragher, Tracey M

    2015-01-01

    The purpose of this paper is to explore prison drug injecting prevalence, identify any changes in injecting prevalence and practice during imprisonment and explore views on prison needle exchange. An empirical prospective cohort survey conducted between 2006 and 2008. The study involved a random sample of 267 remand and sentenced prisoners from a large male category B prison in England where no prison needle exchange operates. Questionnaires were administered with prisoners on reception and, where possible, at one, three and six months during their sentence. In total, 64 per cent were injecting until admission into prison. The majority intended to stop injecting in prison (93 per cent), almost a quarter due to the lack of needle exchange (23 per cent). Yet when hypothetically asked if they would continue injecting in prison if needle exchange was freely available, a third of participants (33 per cent) believed that they would. Injecting cessation happened on prison entry and appeared to be maintained during the sentence. Not providing sterile needles may increase risks associated with injecting for prisoners who continue to inject. However, providing such equipment may prolong injecting for other prisoners who currently cease injecting on account of needle exchange programmes (NEPs) not being provided in the UK prison setting. Practical implications - Not providing sterile needles may increase risks associated with injecting for prisoners who continue to inject. However, providing such equipment may prolong injecting for other prisoners who currently cease injecting on account of NEPs not being provided in the UK prison setting. This survey is the first to question specifically regarding the timing of injecting cessation amongst male prisoners and explore alongside intention to inject should needle exchange facilities be provided in prison.

  13. Underwater fuel handling equipment maintenance. Verification of design assumptions, specific problems and tools, case study

    International Nuclear Information System (INIS)

    Kurek, J.B.

    1995-01-01

    The majority of CANDU Fuel Transfer System equipment at Pickering is located under fourteen feet of water, as dictated by the containment and shielding requirements. Such arrangement, however, creates specific problems with equipment maintenance. Each single piece of equipment serves two generating units, which means in case of defect- double losses on production, or two units shut down simultaneously for planned maintenance. The requirement for underwater maintenance was not anticipated at the design stage, which multiples the level of difficulty, and creates requirement for developing special tools for each work. Removal of the damaged fuel from the receiving bays and decontamination of submerged equipment is also part of the problem. The purpose of this presentation is to share our experience with the designers, operators, maintenance mechanics and technical personnel of the other CANDU generating stations

  14. Chapter 11. Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.; Culver, Gene

    1998-01-01

    Most geothermal fluids, because of their elevated temperature, contain a variety of dissolved chemicals. These chemicals are frequently corrosive toward standard materials of construction. As a result, it is advisable in most cases to isolate the geothermal fluid from the process to which heat is being transferred. The task of heat transfer from the geothermal fluid to a closed process loop is most often handled by a plate heat exchanger. The two most common types used in geothermal applications are: bolted and brazed. For smaller systems, in geothermal resource areas of a specific character, downhole heat exchangers (DHEs) provide a unique means of heat extraction. These devices eliminate the requirement for physical removal of fluid from the well. For this reason, DHE-based systems avoid entirely the environmental and practical problems associated with fluid disposal. Shell and tube heat exchangers play only a minor role in low-temperature, direct-use systems. These units have been in common use in industrial applications for many years and, as a result, are well understood. For these reasons, shell and tube heat exchangers will not be covered in this chapter.

  15. Manufacture of power station heat exchangers using modern production technology

    International Nuclear Information System (INIS)

    Genzlinger, W.; Hoffmann, J.; Ohlhaeuser, K.

    1986-01-01

    Heat exchangers of high quality and operational safety can only be fabricated economically if fabrication is as 'simple' as possible and can be controlled and if, through value analysis, the work flows can be mechanized and automated and the following requirements are met: use of materials that are easy to work with for the application considered, choice of product designs and wall thicknesses that offer favourable conditions for processing and non-destructive testing, placing of seams in such a way that good accessibility for welding and minimum residual welding stresses are assured, minimizing the number of welding seams, use of automatic welding machines for submerged-arc welding and electronically controlled sources of welding current - semi-automatic equipment for spatter-free interfaces (pulse technique), electronically controlled equipment for welding in rollers and pipes and CNC-controlled machining centres for drilling pipe galleries (deep-hole drilling) and baffle plates and for machining the sealing elements after welding. Continuous inspections in each phase of fabrication assures that heat exchangers are made which fully meet the requirements of nuclear power station operators. (orig.)

  16. Kitchen Units for the Classroom.

    Science.gov (United States)

    Illinois Univ., Urbana. Agricultural Experiment Station.

    This study is concerned with functional standards for storage of equipment, use of space, and arrangement of work centers in kitchen units for four students within a high school foods laboratory. Lists of equipment and measurements for storage areas are given for each work center. (FS)

  17. The development of special equipment amplitude detection instrument based on DSP

    International Nuclear Information System (INIS)

    Dai Sidan; Chen Ligang; Lan Peng; Wang Huiting; Zhang Liangxu; Wang Lin

    2014-01-01

    Development and industrial application of special equipment plays an important role in the development of nuclear energy process. Equipment development process need to do a lot of tests, amplitude detection is a key test,it can analysis the device's electromechanical and physical properties. In the industrial application, the amplitude detection can effectively reflect the operational status of the current equipment, the equipment can also be a certain degree of fault diagnosis, identify problems in a timely manner. The main development target in this article is amplitude detection of special equipment. This article describes the development of special equipment amplitude detection instrument. The instrument uses a digital signal processor (DSP) as the central processing unit, and uses the DSP + CPLD + high-speed AD technology to build a complete set of high-precision signal acquisition and analysis processing systems, rechargeable lithium battery as the powered device. It can do a online monitoring of special equipment amplitude, speed parameters by acquiring and analysing the tachometer signal in the special equipment, and locally display through the LCD screen. (authors)

  18. Electronic detecting equipment in the Camac standard

    International Nuclear Information System (INIS)

    Basiladze, S.G.

    1981-01-01

    Basic tends of development of electron detecting equipment of modern facilities for experiments in nuclear physics are considered. Special attention is paid to developments of specialized hybrid integrated circuits, specialized processors for selection of events, usage of integrated circuits of memories in detecting units as well as to prospects of developing nuclear electronics standards [ru

  19. Mobile units to hydro geochemistry characterization

    International Nuclear Information System (INIS)

    Gomez, P.; Martinez, B.; Turrero, M.J.

    1994-01-01

    This report shows the mobile units for hydro geochemical studies. The authors analyze the work of mobile unit and the cars that conform the unit: Sampling car and analysis car: The sampling and equipment are took into account as well

  20. Kitchen Appliance Upgrades Improve Water Efficiency at DOD Exchange Facilities: Best Management Practice Case Study #11: Commercial Kitchen Equipment (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2011-09-01

    The Exchange, formerly the Army and Air Force Exchange Service (AAFES), is a joint military activity and the U.S. Department of Defense?s (DOD) oldest and largest retailer. The Exchange is taking a leadership role in water efficiency improvements in their commercial kitchens by integrating water efficiency concepts into the organization?s overall sustainability plan and objectives.

  1. Kidney Exchange to Overcome Financial Barriers to Kidney Transplantation.

    Science.gov (United States)

    Rees, M A; Dunn, T B; Kuhr, C S; Marsh, C L; Rogers, J; Rees, S E; Cicero, A; Reece, L J; Roth, A E; Ekwenna, O; Fumo, D E; Krawiec, K D; Kopke, J E; Jain, S; Tan, M; Paloyo, S R

    2017-03-01

    Organ shortage is the major limitation to kidney transplantation in the developed world. Conversely, millions of patients in the developing world with end-stage renal disease die because they cannot afford renal replacement therapy-even when willing living kidney donors exist. This juxtaposition between countries with funds but no available kidneys and those with available kidneys but no funds prompts us to propose an exchange program using each nation's unique assets. Our proposal leverages the cost savings achieved through earlier transplantation over dialysis to fund the cost of kidney exchange between developed-world patient-donor pairs with immunological barriers and developing-world patient-donor pairs with financial barriers. By making developed-world health care available to impoverished patients in the developing world, we replace unethical transplant tourism with global kidney exchange-a modality equally benefitting rich and poor. We report the 1-year experience of an initial Filipino pair, whose recipient was transplanted in the United states with an American donor's kidney at no cost to him. The Filipino donor donated to an American in the United States through a kidney exchange chain. Follow-up care and medications in the Philippines were supported by funds from the United States. We show that the logistical obstacles in this approach, although considerable, are surmountable. © 2016 The American Society of Transplantation and the American Society of Transplant Surgeons.

  2. Ceramic heat exchangers. (Latest citations from the US Patent bibliographic file with exemplary claims). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-02-01

    The bibliography contains citations of selected patents concerning the use of ceramic materials in the manufacture of industrial heat exchangers. The focus is on ceramics that display resistance to high temperature corrosion, abrasion, wear, and thermal shock. The design and fabrication of rotary, regenerative, and recuperative heat exchangers are discussed. Ceramic heat exchangers for uses in gas turbines, waste heat recovery equipment, and central heating systems are described. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  3. Ceramic heat exchangers. (Latest citations from the US Patent bibliographic file with exemplary claims). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    The bibliography contains citations of selected patents concerning the use of ceramic materials in the manufacture of industrial heat exchangers. The focus is on ceramics that display resistance to high temperature corrosion, abrasion, wear, and thermal shock. The design and fabrication of rotary, regenerative, and recuperative heat exchangers are discussed. Ceramic heat exchangers for uses in gas turbines, waste heat recovery equipment, and central heating systems are described. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  4. Optimization of porous microchannel heat exchanger

    Science.gov (United States)

    Kozhukhov, N. N.; Konovalov, D. A.

    2017-11-01

    The technical progress in information and communication sphere leads to a sharp increase in the use of radio electronic devices. Functioning of radio electronics is accompanied by release of thermal energy, which must be diverted from the heat-stressed element. Moreover, using of electronics at negative temperatures, on the contrary, requires supply of a certain amount of heat to start the system. There arises the task of creating a system that allows both to supply and to divert the necessary amount of thermal energy. The development of complex thermostabilization systems for radio electronic equipment is due to increasing the efficiency of each of its elements separately. For more efficient operation of a heat exchanger, which directly affects the temperature of the heat-stressed element, it is necessary to calculate the mode characteristics and to take into account the effect of its design parameters. The results of optimizing the microchannel heat exchanger are presented in the article. The target optimization functions are the mass, pressure drop and temperature. The parameters of optimization are the layout of porous fins, their geometric dimensions and coolant flow. For the given conditions, the optimum variant of porous microchannel heat exchanger is selected.

  5. Experimental analysis of an air-to-air heat recovery unit for balanced ventilation systems in residential buildings

    International Nuclear Information System (INIS)

    Fernandez-Seara, Jose; Diz, Ruben; Uhia, Francisco J.; Dopazo, Alberto; Ferro, Jose M.

    2011-01-01

    This paper deals with the experimental analysis of an air-to-air heat recovery unit equipped with a sensible polymer plate heat exchanger (PHE) for balanced ventilation systems in residential buildings. The PHE is arranged in parallel triangular ducts. An experimental facility was designed to reproduce the typical outdoor and exhaust air conditions with regard to temperature and humidity. The unit was tested under balanced operation conditions, as commonly used in practice. A set of tests was conducted under the reference operating conditions to evaluate the PHE performance. Afterwards, an experimental parametric analysis was conducted to investigate the influence of changing the operating conditions on the PHE performance. Experiments were carried out varying the inlet fresh air temperature, the exhaust air relative humidity and the air flow rate. The experimental results are shown and discussed in this paper.

  6. Assessment of the Performance of a Ventilated Window Coupled with a Heat Recovery Unit through the Co-Heating Test

    Directory of Open Access Journals (Sweden)

    Ludovico Danza

    2016-01-01

    Full Text Available The aim of the article is to describe the results of an experimental campaign based on the assessment of a heat recovery unit coupled with a dynamic window. Two fully monitored and calibrated outdoor test cells are used, in order to evaluate the energy performance and the related thermal comfort. The former presents a traditional window with double-glazing, aluminum frame and indoor blind and a centrifugal extractor for the air circulation. The latter is equipped with a dynamic window with ventilated and blinded double-glazing provided with a heat exchanger. The connection of the dynamic window and heat recovery unit provides different actions: heat recovery; heat transfer reduction; pre-heating before the exchanger. Different operating configurations allowed the trends of the dynamic system to be assessed in different seasons in terms of energy saving, thermal comfort behavior and energy efficiency. The results showed an overall lower consumption of the innovative system, both in winter and summer, with 20% and 15% energy saving, respectively. In general, the dynamic system provided the best comfort conditions, even if it involves a worse behavior than expected, in the summer season.

  7. Non-linear advanced control of the LHC inner triplet heat exchanger test unit

    International Nuclear Information System (INIS)

    Vinuela, E. Blanco; Cubillos, J. Casas; Prada Moraga, C. de; Cristea, S.

    2002-01-01

    The future Large Hadron Collider (LHC) at CERN will include eight interaction region final focus magnet systems, the so-called 'Inner Triplet', one on each side of the four beam collision points. The Inner Triplets will be cooled in a static bath of pressurized He II nominally at 1.9 K. This temperature is a control parameter and has very severe constraints in order to avoid the transition from the superconducting to normal resistive state. The main difference in these special zones with respect to a regular LHC cell is higher dynamic heat load unevenly distributed which modifies largely the process characteristics and hence the controller performance. Several control strategies have already been tested at CERN in a pilot plant (LHC String Test) which reproduced a LHC half-cell. In order to validate a common control structure along the whole LHC ring, a Nonlinear Model Predictive Control (NMPC) has been developed and implemented in the Inner Triplet Heat Exchanger Unit (IT-HXTU) at CERN. Automation of the Inner Triplet setup and the advanced control techniques deployed based on the Model Based Predictive Control (MBPC) principle are presented

  8. A comparative study of United States and China exchange rate behavior: A co integration analysis

    Directory of Open Access Journals (Sweden)

    Khuram Shafi

    2015-02-01

    Full Text Available Exchange rates always affect the prices of the imports and export of products and services in which countries are trading with other parts of the world. Therefore, exchange rate calculation is one of the essential issues for making appropriate policies. This research investigates the determinants of trade, i.e. import, export, industrial growth, consumption level and oil prices fluctuation, which bring changes in exchange rate and their influence eventually on balance of payments. Data of defined variables was collected on yearly basis for China and USA for thirty one years. By applying cointegration, it is estimated that there existed a long run relationship in both countries. USA and China had significant and correct signs on the short run dynamic and some of the factors did not. Exchange rate did not granger cause balance of payment and balance of payment did not granger cause exchange rate. In conclusion, we found that determinants of balance of trade could affect the exchange rates, also, these rates had considerable effect (positive or negative on balance of payments. In this twofold study, we found relationship of exchange rate with selected determinants of trade, and also examined their bilateral effect, and then made contrast of both countries.

  9. Statistical Analysis of the Exchange Rate of Bitcoin.

    Science.gov (United States)

    Chu, Jeffrey; Nadarajah, Saralees; Chan, Stephen

    2015-01-01

    Bitcoin, the first electronic payment system, is becoming a popular currency. We provide a statistical analysis of the log-returns of the exchange rate of Bitcoin versus the United States Dollar. Fifteen of the most popular parametric distributions in finance are fitted to the log-returns. The generalized hyperbolic distribution is shown to give the best fit. Predictions are given for future values of the exchange rate.

  10. Reliability performance of standby equipment with periodic testing

    International Nuclear Information System (INIS)

    Sim, S.H.

    1985-11-01

    In this report, the reliability performance of standby equipment subjected to periodic testing is studied. analytical expressions have been derived for reliability measures, such as the man accumulated operating time to failure, the expected number of tests between two consecutive failures, the mean time to failure following an emergency start-up and the probability of failing to complete an emergency mission of a specified duration. These results are useful for the reliability assessment of standby equipment such as combustion turbine units of the emergency power supply system, and of the Class III power system at a nuclear generating station

  11. 47 CFR 76.923 - Rates for equipment and installation used to receive the basic service tier.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Rates for equipment and installation used to... § 76.923 Rates for equipment and installation used to receive the basic service tier. (a) Scope. (1... control units; and (iii) Inside wiring. (2) Subscriber charges for such equipment shall not exceed charges...

  12. Prophylactic and thermovision measurements of electric machines and equipment

    Energy Technology Data Exchange (ETDEWEB)

    Jedlicka, R; Brestovansky, L [Atomova Elektraren Bohunice, Jaslovske Bohunice (Slovakia)

    1997-12-31

    High-voltage measurements of generators, unit and service transformers and some significant motor drives used at a nuclear power plant are described in this paper. Thermovision measurements of electric machines and distribution systems are dealt with in the second part of the paper. Power electric equipment represent one of the most significant components of a nuclear power plant. Turbine mechanical energy is converted into the electrical energy within these equipment. Power generated by generators is transformed by transformers so that it can achieve appropriate parameters for both the transmission over the distribution system and the power plant service power supply. The service power supply switchboards and cables provide supply to motors and other consumers necessary for the nuclear power plant technological process. The whole complex of equipment has to be maintained in good technical conditions. It is necessary to make thermovision and prophylactic measurements to identify and verify the electric equipment technical condition. The mentioned measurements warn the operation staff in advance against both gradual deterioration of power connection contact resistances, i.e. power connections overheating, and the machine insulation systems condition deterioration. The operation staff try to prevent the electric equipment operation accidents by early removing the detected failures, thus, improving the nuclear safety. In order to provide the above-mentioned activities a special prophylactic measurement group was established at the NPP Bohunice in 1983. The group specialists make following types of measurements. 1. Prophylactic measurements of electric machines. Prophylactics of 220 MW generators and 6 MW service power generators; Prophylactics of both unit and service transformers and VHV bushings; Prophylactics of major 6 kV motor drives. 2. Thermovision measurements of current connections. (Abstract Truncated)

  13. Use of ice storage equipment in the food industry

    Energy Technology Data Exchange (ETDEWEB)

    Vries, H. de

    1984-01-01

    The manufacture of foods in its widest sense demands a 'balanced supply of cooling'. Whenever 'cold requirement' occurs in different ways during production, the ice storage equipment in particular for 'cooling supplies'. The cooling performance (amount of cold from horizontal tubes and slabs or from horizontal pipes given off to the water flowing past) that can be expected from modern ice storage equipment, is made clear numerically. The way the storage vessel is constructed and its design have particular influence on the energy-saving quality (stirring mechanism with high performance at low pump capacity). Optimisation results for a plate evaporator design combined with a heat exchange system are presented. These include running cost savings of up to 18% in a yoghurt factory, a maltery and an ice cream factory. By means of this heat pump compound, environmental energy can be used in cold storage.

  14. The dry heat exchanger calorimeter system

    International Nuclear Information System (INIS)

    Renz, D.P.; Wetzel, J.R.; James, S.J.; Kasperski, P.W.; Duff, M.F.

    1991-01-01

    A radiometric isothermal heat flow calorimeter and preconditioner system that uses air instead of water as the heat exchange medium has been developed at Mound. The dry heat exchanger calorimeter is 42 inches high by 18 inches in diameter and the preconditioner is a 22 inch cube, making it extremely compact compared to existing units. The new system is ideally suited for transportable, stand-alone, or glovebox applications. Preliminary tests of the system have produced sample measurements with standard deviations less than 0.25% and sample errors less than 0.50%. These tests have shown that the dry heat exchanger system will yield acceptance data with an accuracy comparable to those of Mound water bath systems now in use. 4 figs., 1 tab

  15. A range of equipment for dental radiography

    International Nuclear Information System (INIS)

    Bergman, G.P.M.; Clement, S.L.

    1980-01-01

    A brief review of the history of dental radiography is followed by a description of the latest Philips equipment, ranging from compact units for intra-oral radiography to advanced systems for panoramic techniques and skull radiography. The advantages of automatic exposure control and automatic film processing are also discussed. In conclusion, some probable future trends are forecast. (Auth.)

  16. On the preparation of fire-wood splitting machines equipped with feeder devices

    International Nuclear Information System (INIS)

    Jaeaeskelaeinen, M.

    1995-01-01

    As part of the Bionergy research programme, the TTS Institute's Department of Forestry conducted a study on firewood splitting machines manufactured by Bilke Oy and Peurala Oy. The said machines are the first of their kind in Finland to be equipped with a feeder device. The Bilke unit is fed by a conveyor belt arrangement while the Peurala unit is equipped with a feeder roll. In addition, both machine types are equipped with a conveyor belt discharging device (e.g. for discharging split wood directly into a trailer). The Bilke unit can also be operated on extraction racks in the woods as the stems due to be split are fed into it from the side and the conveyor discharges the split wood rearwards into the trailer. The trailer can be hooked onto the splitting unit's draw-hook. At the landing, the Bilke unit was used to split a total of 14.2 m 3 and the Peurala unit 8.0 m 3 of approx. 3-metrelong stems averaging 9 cm in diameter. In addition to this, the Bilke unit was used to split ca. 17 m 3 of 3.5 metre-long stems with on average diameter of ca. 6 cm; the stems were in bunches alongside the extraction racks. The person operating the machines for the purposes of this study was a 27-year- old forest worker. The mean productivity achieved at the landing when using the Bilke unit was 7.7 m 3 while that of the Peurala unit was 5.8 m 3 per effective hour. When operated in the woods, the productivity achieved with the Bilke unit (excluding felling-cross cutting-delimbing-bunching and forest haulage work) was 2.8 m 3 /h. When applying a productivity of 1.7 m 3 for felling-cross cutting- delimbing-bunching work and 5.5. m 3 for forest haulage, the entire harvesting chain's productivity was 0.9 m 3 per effective hour

  17. Optimization model of a system of crude oil distillation units with heat integration and metamodeling

    International Nuclear Information System (INIS)

    Lopez, Diana C; Mahecha, Cesar A; Hoyos, Luis J; Acevedo, Leonardo; Villamizar Jaime F

    2010-01-01

    The process of crude distillation impacts the economy of any refinery in a considerable manner. Therefore, it is necessary to improve it taking good advantage of the available infrastructure, generating products that conform to the specifications without violating the equipment operating constraints or plant restrictions at industrial units. The objective of this paper is to present the development of an optimization model for a Crude Distillation Unit (CDU) system at a ECOPETROL S.A. refinery in Barrancabermeja, involving the typical restrictions (flow according to pipeline capacity, pumps, distillation columns, etc) and a restriction that has not been included in bibliographic reports for this type of models: the heat integration of streams from Atmospheric Distillation Towers (ADTs) and Vacuum Distillation Towers (VDT) with the heat exchanger networks for crude pre-heating. On the other hand, ADTs were modeled with Metamodels in function of column temperatures and pressures, pump a rounds flows and return temperatures, stripping steam flows, Jet EBP ASTM D-86 and Diesel EBP ASTM D-86. Pre-heating trains were modeled with mass and energy balances, and design equation of each heat exchanger. The optimization model is NLP, maximizing the system profit. This model was implemented in GAMSide 22,2 using the CONOPT solver and it found new operating points with better economic results than those obtained with the normal operation in the real plants. It predicted optimum operation conditions of 3 ADTs for constant composition crude and calculated the yields and properties of atmospheric products, additional to temperatures and duties of 27 Crude Oil exchangers.

  18. Probes for inspections of heat exchanges installed at nuclear power plants type PWR by eddy current method

    International Nuclear Information System (INIS)

    Silva, Alonso F.O.

    2007-01-01

    From all non destructive examination methods usable to perform integrity evaluation of critical equipment installed at nuclear power plants (NPP), eddy current test (ET) may be considered the most important one, when examining heat exchangers. For its application, special probes and reference calibration standards are employed. In pressurized water reactor (PWR) NPPs, a particularly critical equipment is the steam generator (SG), a huge heat exchanger that contains thousands of U-bend thin wall tubes. Due to its severe working conditions (pressure and temperature), that component is periodically examined by means of ET. In this paper a revision of the operating fundamentals of the main ET probes, used to perform SG inspections is presented. (author)

  19. Electrical equipment performance under severe accident conditions (BWR/Mark 1 plant analysis): Summary report

    International Nuclear Information System (INIS)

    Bennett, P.R.; Kolaczkowski, A.M.; Medford, G.T.

    1986-09-01

    The purpose of the Performance Evaluation of Electrical Equipment during Severe Accident States Program is to determine the performance of electrical equipment, important to safety, under severe accident conditions. In FY85, a method was devised to identify important electrical equipment and the severe accident environments in which the equipment was likely to fail. This method was used to evaluate the equipment and severe accident environments for Browns Ferry Unit 1, a BWR/Mark I. Following this work, a test plan was written in FY86 to experimentally determine the performance of one selected component to two severe accident environments

  20. Bruce Unit 2 lay-up engineering assessment

    International Nuclear Information System (INIS)

    Iley, D.

    1995-01-01

    The overall lay-up program initiated as a result of the strategic decision to shut down Bruce A unit 2 is briefly described as an introduction to the engineering assessment of the unit 2 systems. The assessment has identified the need to prepare 67 system and 9 equipment lay-up specifications. A summary of the selected system specifications is described. A complete summary and the specifications and the status of unit 2 systems and equipment required to support lay-up and/or the other three operating units is available on request due to the volume of the information. Some logistical details of the lay-up implementation plans, results, and problems to date demonstrate the complexity of the lay-up requirements for a nuclear unit in a multi-unit CANDU station. (author)

  1. 46 CFR 108.223 - Guards on exposed equipment.

    Science.gov (United States)

    2010-10-01

    ... have hand covers, guards, or rails installed on all belts, gears, shafts, pulleys, sprockets, spindles... 46 Shipping 4 2010-10-01 2010-10-01 false Guards on exposed equipment. 108.223 Section 108.223 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN...

  2. Consolidation equipment for irradiated nuclear fuel channels

    International Nuclear Information System (INIS)

    Taguchi, M.; Komatsu, Y.; Ose, T.

    1989-01-01

    The authors have developed and put into use a new type of mechanical consolidation equipment for irradiated nuclear fuel channels. This includes round-slice cutting of the top 100mm of the fuel channel with a guillotine cutter, and press cutting of the two corners of the remaining length of the fuel channel. Four guillotine blades work in combination with receiving blades arranged inside the fuel channel to cut the top 100mm, including the clips and spacers, of the fuel channel into a round slice. A press assembled in the consolidation equipment then presses the slice to achieve volume reduction. The press cutting operation uses two press cutting blades arranged inside the fuel channel and the receiving blades outside the fuel channel. The remaining length of fuel channel is cut off into L-shaped pieces by press cutting. This consolidation equipment is highly efficient because the round-slice cutting, pressing, and press cutting are all achieved by one unit

  3. Low-energy house in Sisimiut - Measurement equipment

    Energy Technology Data Exchange (ETDEWEB)

    Hvidthoeft Delff Andersen, P.; Rode, C.; Madsen, Henrik

    2013-08-15

    This paper documents the measurement equipment in a low-energy house in Sisimiut, Greenland. Detailed measurements are being taken on energy consumption, indoor temperatures, floor heating, ventilation, open/closed state of doors and windows, and indoors climate. Equipped with a central control unit, experiments can be designed in order to study heat dynamics of the building. It is described how to plan and execute such experiments in one apartment in the building. The building also features both a solar thermal system and extra buffer tank facilitating testing of storage strategies on the power generated by the solar thermal system. A weather station equipped with thermometer, pyranometer and anemometer is installed on the building as well. Finally, it is described how to retrieve data from an SQL server which is configured to take monthly backups. R functions have been implemented to fetch and prepare the data for time series analysis. Examples are given on the use of these. (Author)

  4. Prototype Vent Gas Heat Exchanger for Exploration EVA - Performance and Manufacturing Characteristics

    Science.gov (United States)

    Quinn, Gregory J.; Strange, Jeremy; Jennings, Mallory

    2013-01-01

    NASA is developing new portable life support system (PLSS) technologies, which it is demonstrating in an unmanned ground based prototype unit called PLSS 2.0. One set of technologies within the PLSS provides suitable ventilation to an astronaut while on an EVA. A new component within the ventilation gas loop is a liquid-to-gas heat exchanger to transfer excess heat from the gas to the thermal control system s liquid coolant loop. A unique bench top prototype heat exchanger was built and tested for use in PLSS 2.0. The heat exchanger was designed as a counter-flow, compact plate fin type using stainless steel. Its design was based on previous compact heat exchangers manufactured by United Technologies Aerospace Systems (UTAS), but was half the size of any previous heat exchanger model and one third the size of previous liquid-to-gas heat exchangers. The prototype heat exchanger was less than 40 cubic inches and weighed 2.57 lb. Performance of the heat exchanger met the requirements and the model predictions. The water side and gas side pressure drops were less 0.8 psid and 0.5 inches of water, respectively, and an effectiveness of 94% was measured at the nominal air side pressure of 4.1 psia.

  5. Treatment of radioactive ionic exchange resins by super- and sub-critical water oxidation (SCWO)

    International Nuclear Information System (INIS)

    Kim, Kyeongsook; Son, Soon Hwan; Kim, Kwang Sin; Han, Joo Hee; Han, Kee Do; Do, Seung Hoe

    2010-01-01

    As the usage of ion exchange resins increases the inventory of spent ion exchange resins increases in nuclear power plants. This study is to find an environmental-friendly process to treat theses spent resins. The test samples were prepared by diluting the slurry made by wet ball milling the spent cationic exchange resins for 24 h. The spent cationic exchange resins were separated from mixed ion exchange resins by a fluidized bed gravimetric separator. The decomposition of the samples was investigated with super-critical water oxidation (SCWO) equipment. A statistical test method - the central composite design as a statistical design of experiments - was adopted to find the optimum condition to decompose the spent exchange resins. The optimum condition was 60% of excess oxygen, 22.5 min of residence time, 0.615 wt% of NaOH, 358 of reaction temperature, and 3600 psi of reaction pressure, which is a sub-critical condition. The liquid product of the decomposition has the characteristics of 80-185 ppm of COD (Chemical Oxygen Demand), 4.0-6.0 of pH, and <1.0 ppm of corrosive components (Ni, Fe, Cr, and Mo). The exhaust gas from the SCWO equipment contained NOx of 0 ppm, SOx of 3 ppm (environment exhaust standard in Korea: NOx 200 ppm, SOx 300 ppm). Co-substituted mock samples were prepared to simulate spent cationic exchange resins from nuclear power plants which can contain radioactive Co isotopes. The conditions to obtain organic compound destruction ratio which conforms the effluent stand for the mock samples were found. The treated water filtered with 0.2-filter contained less than 1 ppm of Co. Thus Co recovery rate of more 99% was achieved.

  6. A fundamentally new approach to air-cooled heat exchangers.

    Energy Technology Data Exchange (ETDEWEB)

    Koplow, Jeffrey P.

    2010-01-01

    We describe breakthrough results obtained in a feasibility study of a fundamentally new architecture for air-cooled heat exchangers. A longstanding but largely unrealized opportunity in energy efficiency concerns the performance of air-cooled heat exchangers used in air conditioners, heat pumps, and refrigeration equipment. In the case of residential air conditioners, for example, the typical performance of the air cooled heat exchangers used for condensers and evaporators is at best marginal from the standpoint the of achieving maximum the possible coefficient of performance (COP). If by some means it were possible to reduce the thermal resistance of these heat exchangers to a negligible level, a typical energy savings of order 30% could be immediately realized. It has long been known that a several-fold increase in heat exchanger size, in conjunction with the use of much higher volumetric flow rates, provides a straight-forward path to this goal but is not practical from the standpoint of real world applications. The tension in the market place between the need for energy efficiency and logistical considerations such as equipment size, cost and operating noise has resulted in a compromise that is far from ideal. This is the reason that a typical residential air conditioner exhibits significant sensitivity to reductions in fan speed and/or fouling of the heat exchanger surface. The prevailing wisdom is that little can be done to improve this situation; the 'fan-plus-finned-heat-sink' heat exchanger architecture used throughout the energy sector represents an extremely mature technology for which there is little opportunity for further optimization. But the fact remains that conventional fan-plus-finned-heat-sink technology simply doesn't work that well. Their primary physical limitation to performance (i.e. low thermal resistance) is the boundary layer of motionless air that adheres to and envelops all surfaces of the heat exchanger. Within this

  7. Standard guide for hot cell specialized support equipment and tools

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 Intent: 1.1.1 This guide presents practices and guidelines for the design and implementation of equipment and tools to assist assembly, disassembly, alignment, fastening, maintenance, or general handling of equipment in a hot cell. Operating in a remote hot cell environment significantly increases the difficulty and time required to perform a task compared to completing a similar task directly by hand. Successful specialized support equipment and tools minimize the required effort, reduce risks, and increase operating efficiencies. 1.2 Applicability: 1.2.1 This guide may apply to the design of specialized support equipment and tools anywhere it is remotely operated, maintained, and viewed through shielding windows or by other remote viewing systems. 1.2.2 Consideration should be given to the need for specialized support equipment and tools early in the design process. 1.2.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conv...

  8. Final disposal of spent nuclear fuel-equipment for site characterization

    International Nuclear Information System (INIS)

    Almen, K.; Hansson, K.; Johansson, B.E.; Nilsson, G.; Andersson, O.; Wikberg, P.; Aahagen, H.

    1983-05-01

    The suitability of a certain geological formation as a repository for the final disposal of spent nuclear fuel can be determined only after detailed investigation and analysis. The purpose of the investigations is to provide information on the geology and the hydrology and chemistry of the site concerned. The value of these data largely depends on the way in which they have been collected. The report of the findings should enable the investigating party to evaluate the function and the accuracy of the equipment with which field data have been collected for KBS 3. This report describes the geophysical equipment, the hydraulic testing equipment, the water chemistry sample extracting equipment and the core-logging equipment used. The objectives of the instrument development have been: - to obtain a high data quality. - to collect data automatically in logs and tape recorders for direct transfer to a central processing unit. - to provide back-up in order to counteract loss of data. - to make instrument more efficient. (author)

  9. Confirmation of the seismic resistance of nuclear power plant equipment after assembly

    International Nuclear Information System (INIS)

    Kaznovsky, P. S.; Kaznovsky, A. P.; Saakov, E. S.; Ryasnyj, S. I.

    2013-01-01

    It is shown that the natural frequencies and damping decrements of nuclear power plant equipment can only be determined experimentally and directly at the power generation units (reactors) of nuclear power plants under real disassembly conditions for the equipment, piping network, thermal insulation, etc. A computational experimental method is described in which the natural frequencies and damping decrements are determined in the field and the seismic resistance is reevaluated using these values. This method is the basis of the standards document “Methods for confirming the dynamic characteristics of systems and components of the generating units of nuclear power plants which are important for safety” prepared and introduced in 2012.

  10. Fouling detection in heat exchangers by Takagi-Sugeno observers

    International Nuclear Information System (INIS)

    Delrot, Sabrina

    2012-01-01

    The phenomenon of fouling in heat exchangers is currently an important topic. Indeed, the fouling is a costly issue that increases the energy loss (directly or indirectly through an over-sizing of the equipment), and therefore increases the water consumption. As a side effect, fouling increases CO 2 consumption that leads to environmental consequences. Fouling can be detected either on local scale, using expensive and specific sensors or on global scale. Global estimation of fouling can be done by measuring the variation of the mass of the exchanger, or by estimating the efficiency of the exchanger through the transfer coefficient. These two methods require very restricting conditions: a powered exchanger to measure mass variation and a steady state exchanger to estimate the efficiency. The work introduced in this thesis deals with the development of non-linear observers that detect fouling early enough to start an efficient cleaning process. As a beginning, a finite element model of a counter current tubular exchanger was proposed. Then three approaches, based on non-linear Takagi-Sugeno observers, were suggested to detect early fouling in heat exchangers. First approach consisted in a set of observers that estimated the parameters of fouling effect through an interpolation method. The second approach proposed a polynomial Takagi-Sugeno observer, using the theory of sums of squares. Finally, a observer of Takagi-Sugeno type with unknown inputs was developed. As a conclusion, a comparison between those different methods was done. (author)

  11. Mixing systems for wet and dry plumes and cleaning equipment for the heat exchangers of the dry section. Two indispensible components of an effective and safe hybrid cooling tower

    International Nuclear Information System (INIS)

    Alt, W.

    1990-01-01

    At first glance, the hybrid cooling tower seems to be an ingenious combination of the well known components of an evaporative cooling tower and a dry cooling tower. The calculation of the air mass flows for both the wet and dry sections required to achieve an invisible plume does not represent an unsolvable problem to the engineer experienced in thermodynamics. The same also applies to the dimensioning of the heat exchangers and cooling fills. The hybrid cooling tower requires a well designed mixing system in order to ideally mix, the dry plume into the wet plume. If the cooling tower proves its efficiency during commissioning it is important that the ratio of the performance of the wet section to that of the dry section be maintained also in the long term. The performance of the fill in a wet cooling tower is consistently stable. Dirt deposits can form very quickly on the inner and outer surfaces of the heat exchangers of the dry section. In this case the thermal resistance increases rapidly. The respective performance of the wet and dry sections is then no longer balanced and the invisibility of the plume is no longer assured. This can be avoided by providing appropriate cleaning equipment

  12. EFFICIENCY OF FOREIGN EXCHANGE MARKETS: A DEVELOPING COUNTRY PERSPECTIVE

    Directory of Open Access Journals (Sweden)

    Guneratne B Wickremasinghe

    2005-01-01

    Full Text Available This study tests weak and semi-strong form efficiency of the foreign exchange market in Sri Lanka during the recent float using six bilateral exchange rates. Weak-form efficiency is examined using unit root tests while semi-strong form efficiency is tested using co-integration, Granger causality tests and variance decomposition analysis. Results indicate that the Sri Lankan foreign exchange market is consistent with the weak-form of the efficient market hypothesis (EMH. However, the results provide evidence against the semi-strong version of the EMH. These results have important implications for government policy makers and participants in the foreign exchange market of Sri Lanka.

  13. Spectrophotometric determination of silica in water with Hach equipment

    International Nuclear Information System (INIS)

    Acosta L, E.

    1992-06-01

    The method for the determination of the silica element in water, demineralized water, raw waters, laundry waters, waters treated with ion exchange resins and sea waters using the indicated technique in the operation manual of the Hach equipment with a DR/3 spectrophotometer is described. This method covers the determination of the silica element in the interval from 0 to 1.5 mg/l on 50 ml. of base sample. These limits its can be variable if the size of the used aliquot one is changed for the final determination of the silica element. (Author)

  14. Spectrophotometric determination of fluorides in water with Hach equipment

    International Nuclear Information System (INIS)

    Acosta L, E.

    1994-11-01

    The spectrophotometric method for the determination of the fluoride ion in water, demineralized water, raw waters, laundry waters and waters treated with ion exchange resins , using the technique and the SPADNS coloring indicated in the operation manual of the Hach equipment is described. This method covers the determination of the fluoride ion in the range from 0 to 2 mg/l on 25 ml. of radioactive base sample. These limits can be variable if the size of the used aliquot one is changed for the final determination of the fluoride ion. (Author)

  15. Tube-in-shell heat exchangers

    International Nuclear Information System (INIS)

    Richardson, J.

    1976-01-01

    Tube-in-shell heat exchangers normally comprise a bundle of parallel tubes within a shell container, with a fluid arranged to flow through the tubes in heat exchange with a second fluid flowing through the shell. The tubes are usually end supported by the tube plates that separate the two fluids, and in use the tube attachments to the tube plates and the tube plates can be subject to severe stress by thermal shock and frequent inspection and servicing are required. Where the heat exchangers are immersed in a coolant such as liquid Na such inspection is difficult. In the arrangement described a longitudinally extending central tube is provided incorporating axially spaced cylindrical tube plates to which the opposite ends of the tubes are attached. Within this tube there is a tubular baffle that slidably seals against the wall of the tube between the cylindrical tube plates to define two co-axial flow ducts. These ducts are interconnected at the closed end of the tube by the heat exchange tubes and the baffle comprises inner and outer spaced walls with the interspace containing Ar. The baffle is easily removable and can be withdrawn to enable insertion of equipment for inspecting the wall of the tube and tube attachments and to facilitate plugging of defective tubes. Cylindrical tube plates are believed to be superior for carrying pressure loads and resisting the effects of thermal shock. Some protection against thermal shock can be effected by arranging that the secondary heat exchange fluid is on the tube side, and by providing a thermal baffle to prevent direct impingement of hot primary fluid on to the cylindrical tube plates. The inner wall of the tubular baffle may have flexible expansible region. Some nuclear reactor constructions incorporating such an arrangement are described, including liquid metal reactors. (U.K.)

  16. High-speed three-frame image recording system using colored flash units and low-cost video equipment

    Science.gov (United States)

    Racca, Roberto G.; Scotten, Larry N.

    1995-05-01

    This article describes a method that allows the digital recording of sequences of three black and white images at rates of several thousand frames per second using a system consisting of an ordinary CCD camcorder, three flash units with color filters, a PC-based frame grabber board and some additional electronics. The maximum framing rate is determined by the duration of the flashtube emission, and for common photographic flash units lasting about 20 microsecond(s) it can exceed 10,000 frames per second in actual use. The subject under study is strobe- illuminated using a red, a green and a blue flash unit controlled by a special sequencer, and the three images are captured by a color CCD camera on a single video field. Color is used as the distinguishing parameter that allows the overlaid exposures to be resolved. The video output for that particular field will contain three individual scenes, one for each primary color component, which potentially can be resolved with no crosstalk between them. The output is electronically decoded into the primary color channels, frame grabbed and stored into digital memory, yielding three time-resolved images of the subject. A synchronization pulse provided by the flash sequencer triggers the frame grabbing so that the correct video field is acquired. A scheme involving the use of videotape as intermediate storage allows the frame grabbing to be performed using a monochrome video digitizer. Ideally each flash- illuminated scene would be confined to one color channel, but in practice various factors, both optical and electronic, affect color separation. Correction equations have been derived that counteract these effects in the digitized images and minimize 'ghosting' between frames. Once the appropriate coefficients have been established through a calibration procedure that needs to be performed only once for a given configuration of the equipment, the correction process is carried out transparently in software every time a

  17. Performance test of ex-core high temperature and high pressure water loop test equipment (Contract research)

    International Nuclear Information System (INIS)

    Nakano, Hiroko; Uehara, Toshiaki; Takeuchi, Tomoaki; Shibata, Hiroshi; Nakamura, Jinichi; Matsui, Yoshinori; Tsuchiya, Kunihiko

    2016-03-01

    In Japan Atomic Energy Agency, we started research and development so as to monitor the situations in the Nuclear Plant Facilities during a severe accident, such as a radiation-resistant monitoring camera, a radiation-resistant transmission system for conveying the in-core information, and a heat-resistant signal cable. As a part of developments of the heat-resistant signal cable, we prepared ex-core high-temperature and high-pressure water loop test equipment, which can simulate the conditions of BWRs and PWRs, for evaluating reliability and properties of sheath materials of the cable. This equipment consists of autoclave, water conditioning tank, high-pressure metering pump, preheater, heat exchanger and water purification equipment, etc. This report describes the basic design and the performance test results of ex-core high-temperature and high-pressure water loop test equipment. (author)

  18. Statistical Analysis of the Exchange Rate of Bitcoin.

    Directory of Open Access Journals (Sweden)

    Jeffrey Chu

    Full Text Available Bitcoin, the first electronic payment system, is becoming a popular currency. We provide a statistical analysis of the log-returns of the exchange rate of Bitcoin versus the United States Dollar. Fifteen of the most popular parametric distributions in finance are fitted to the log-returns. The generalized hyperbolic distribution is shown to give the best fit. Predictions are given for future values of the exchange rate.

  19. Statistical Analysis of the Exchange Rate of Bitcoin

    Science.gov (United States)

    Chu, Jeffrey; Nadarajah, Saralees; Chan, Stephen

    2015-01-01

    Bitcoin, the first electronic payment system, is becoming a popular currency. We provide a statistical analysis of the log-returns of the exchange rate of Bitcoin versus the United States Dollar. Fifteen of the most popular parametric distributions in finance are fitted to the log-returns. The generalized hyperbolic distribution is shown to give the best fit. Predictions are given for future values of the exchange rate. PMID:26222702

  20. Choice and maintenance of equipment for electron crystallography.

    Science.gov (United States)

    Mills, Deryck J; Vonck, Janet

    2013-01-01

    The choice of equipment for an electron crystallography laboratory will ultimately be determined by the available budget; nevertheless, the ideal lab will have two electron microscopes: a dedicated 300 kV cryo-EM with a field emission gun and a smaller LaB(6) machine for screening. The high-end machine should be equipped with photographic film or a very large CCD or CMOS camera for 2D crystal data collection; the screening microscope needs a mid-size CCD for rapid evaluation of crystal samples. The microscope room installations should provide adequate space and a special environment that puts no restrictions on the collection of high-resolution data. Equipment for specimen preparation includes a carbon coater, glow discharge unit, light microscope, plunge freezer, and liquid nitrogen containers and storage dewars. When photographic film is to be used, additional requirements are a film desiccator, dark room, optical diffractometer, and a film scanner. Having the electron microscopes and ancillary equipment well maintained and always in optimum condition facilitates the production of high-quality data.

  1. FINANCIAL AND LEGAL CONSIDERATIONS OF THE FOREIGN EXCHANGE RATES ON BANK EXTERNAL TRADING OPERATIONS

    Directory of Open Access Journals (Sweden)

    Ignat Papazov

    2017-06-01

    Full Text Available The term "currency" has different meanings but is usually defined as any means of payment that is not in local currency units. The ratio between the foreign currency and local currency units results into exchange rate. When arranging payment transactions abroad, local entities - natural and legal persons must exchange their national currency in advance for the currency of the country in which they are due or in another currency commonly accepted as an international payment. Under this regime, the national currency is quoted in relation to another currency, that is exchange rate.

  2. New version of VDE 0118 Installation of electrical equipment in underground mining

    Energy Technology Data Exchange (ETDEWEB)

    Gebhardt, L

    1981-10-22

    Preparatory work for the new version of VDE 0188 is reviewed. The major modifications in parts 1 and 2 are mentioned in particular the changes in operating conditions which have been considered and the modified definitions of clean rooms, earthing, underground protective wire system, and mobile operating equipment. Part 2 discusses operating equipment such as motors, inductive voltage transformers, transformers, condensers, lines, lighting units and underground short circuit protection. Part 3 - intrinsically safe electrical equipment, auxiliary circuits, telecommunication systems - will be discussed in a sequel article in Glueckauf.

  3. Organization of the in-core control system connection with the M-6000 computer

    International Nuclear Information System (INIS)

    Golovanov, M.N.; Duma, V.R.; Levin, G.L.; Filatov, V.P.

    1978-01-01

    Problems of organizing communication of a digital computer with the equipment of the in-core control system (CC) are discussed. Three possible modes of joint operation of the CC equipment and the digital computer are given. The off-line control device provides data collection, preliminary processing and recording servicing of peripheral requests, and data exchange with the digital computer; computer-controlled operation of the equipment makes it possible to control input-output operations of the CCS equipment, and also to retain the working capacity of the CCS system when the off-line control device is failed; during file exchange the data are transferred between the computer and the CCS equipment. Requirements for the communication unit design are drawn up. An analysis of existing methods of a digital computer interface with the equipment is presented, and substantiation of the proposed variant of connection of the communication unit directly to the branch highway is given. Operation of the CCS equipment under various conditions is considered. The flowsheet and description of the interface of the M-6000 computer with the CCS equipment are given

  4. Sensors for Metering Heat Flux Area Density and Metrological Equipment for the Heat Flux Density Measurement

    Science.gov (United States)

    Doronin, D. O.

    2018-04-01

    The demand in measuring and studies of heat conduction of various media is very urgent now. This article considers the problem of heat conduction monitoring and measurement in various media and materials in any industries and branches of science as well as metrological support of the heat flux measurement equipment. The main study objects are both the sensors manufactured and facilities onto which these sensors will be installed: different cladding structures of the buildings, awnings, rocket fairings, boiler units, internal combustion engines. The Company develops and manufactures different types of heat flux sensors: thermocouple, thin-film, heterogeneous gradient as well as metrological equipment for the gauging calibration of the heat flux density measurement. The calibration shall be performed using both referencing method in the unit and by fixed setting of the heat flux in the unit. To manufacture heterogeneous heat flux gradient sensors (HHFGS) the Company developed and designed a number of units: diffusion welding unit, HHFGS cutting unit. Rather good quality HHFGS prototypes were obtained. At this stage the factory tests on the equipment for the heat flux density measurement equipment are planned. A high-sensitivity heat flux sensor was produced, now it is tested at the Construction Physics Research Institute (Moscow). It became possible to create thin-film heat flux sensors with the sensitivity not worse than that of the sensors manufactured by Captec Company (France). The Company has sufficient premises to supply the market with a wide range of sensors, to master new sensor manufacture technologies which will enable their application range.

  5. Proposal for the award of a contract for the design, supply, installation, commissioning and testing at CERN of eight helium dryer units for the LHC

    CERN Document Server

    2001-01-01

    This document concerns the award of a contract for the design, supply, installation, commissioning and testing at CERN of eight helium dryer units for the LHC. Following a market survey carried out among 42 firms in ten Member States, a call for tenders (IT-2722/LHC/LHC) was sent on 10 August 2000 to seven firms and three consortia, consisting of two firms each, in seven Member States. By the closing date, CERN had received five tenders from three firms and two consortia in five Member States. The Finance Committee is invited to agree to the negotiation of a contract with the firm COSMI (IT), the lowest bidder fulfilling the technical requirements, for the design, supply, installation, commissioning and testing at CERN of eight helium dryer units for a total amount of 3 514 779 euros, (5 307 329 Swiss francs), not subject to revision, with options for additional equipment for heating the adsorber bed and additional heat exchanger/condenser equipment, for an additional amount of 80 081 euros (120 923 Swiss fra...

  6. Optical system for UV-laser technological equipment

    Science.gov (United States)

    Fedosov, Yuri V.; Romanova, Galina E.; Afanasev, Maxim Ya.

    2017-09-01

    Recently there has been an intensive development of intelligent industrial equipment that is highly automated and can be rapidly adjusted for certain details. This equipment can be robotics systems, automatic wrappers and markers, CNC machines and 3D printers. The work equipment considered is the system for selective curing of photopolymers using a UV-laser and UV-radiation in such equipment that leads to additional technical difficulties. In many cases for transporting the radiation from the laser to the point processed, a multi-mirror system is used: however, such systems are usually difficult to adjust. Additionally, such multi-mirror systems are usually used as a part of the equipment for laser cutting of metals using high-power IR-lasers. For the UV-lasers, using many mirrors leads to crucial radiation losses because of many reflections. Therefore, during the development of the optical system for technological equipment using UV-laser we need to solve two main problems: to transfer the radiation for the working point with minimum losses and to include the system for controlling/handling the radiation spot position. We introduce a system for working with UV-lasers with 450mW of power and a wavelength of 0.45 μm based on a fiber system. In our modelling and design, we achieve spot sizes of about 300 μm, and the designed optical and mechanical systems (prototypes) were manufactured and assembled. In this paper, we present the layout of the technological unit, the results of the theoretical modelling of some parts of the system and some experimental results.

  7. Programming task packages: Peach exchange format

    NARCIS (Netherlands)

    Verhoeff, T.

    2008-01-01

    Programming education and contests have introduced software to help evaluation by executing submitted taskwork. We present the notion of a task package as a unit for collecting, storing, archiving, and exchanging all information concerning a programming task. We also describe a specific format for

  8. Optimization model of a system of crude oil distillation units whit heat integration and meta modeling

    International Nuclear Information System (INIS)

    Lopez, Diana C; Mahecha, Cesar A; Hoyos, Luis J; Acevedo, Leonardo; Villamizar Jaime F

    2009-01-01

    The process of crude distillation impacts the economy of any refinery in a considerable manner. Therefore, it is necessary to improve it taking good advantage of the available infrastructure, generating products that conform to the specifications without violating the equipment operating constraints or plant restrictions at industrial units. The objective of this paper is to present the development of an optimization model for a Crude Distillation Unit (CDU) system at a ECOPETROL S.A. refinery in Barrancabermeja, involving the typical restrictions (flow according to pipeline capacity, pumps, distillation columns, etc) and a restriction that has not been included in bibliographic reports for this type of models: the heat integration of streams from Atmospheric Distillation Towers (ADTs) and Vacuum Distillation Towers (VDT) with the heat exchanger networks for crude pre-heating. On the other hand, ADTs were modeled with Meta models in function of column temperatures and pressures, pumparounds flows and return temperatures, stripping steam flows, Jet EBP ASTM D-86 and Diesel EBP ASTM D-86. Pre-heating trains were modeled with mass and energy balances, and design equation of each heat exchanger. The optimization model is NLP, maximizing the system profit. This model was implemented in GAMSide 22,2 using the CONOPT solver and it found new operating points with better economic results than those obtained with the normal operation in the real plants. It predicted optimum operation conditions of 3 ADTs for constant composition crude and calculated the yields and properties of atmospheric products, additional to temperatures and duties of 27 Crude Oil exchangers.

  9. Procedure to evaluate and control efficiently the operations management of medical equipment in the maintenance unit of a health institution

    Directory of Open Access Journals (Sweden)

    Herrera-Galán Michael

    2018-01-01

    Full Text Available Maintenance management plays a very important role in the success of any company. As a consequence of this, in the year of 2013, a study was carried out in health facilities found in the South Eastern Region of Jamaica with the objective of evaluating the existing Maintenance Management Program for Medical Equipment. Among the results obtained, it showed that there is an inadequacy in the existing program whose principal deficiency is attributed to the operations management. As such, this work proposes a procedure for evaluating and controlling in an efficient manner the operations management within the Biomedical Department which forms part of the South East Regional Health Authority Maintenance Unit (SERHAMU, this latter is found on the premises of the Bustamante Hospital for Children (BHC, Jamaica. The method used to develop the procedure (GOMHO is based fundamentally on the design of: a codification system to identify control registers and to record failures associated with each equipment, a system of placing equipment into categories and further differentiating them based on the potential hazard such pose on the human body in the event of an operational failure. In addition, this procedure gives the SERHAMU at the BHC the opportunity to calculate the amount of human resources needed to carry out efficiently the preventative and corrective maintenance work being demanded on the department. During the implementation phase, the results demonstrated that from the control procedure designed there was an improvement in the planning and carrying out of maintenance work and a better system of monitoring the activities that are executed. Also, it was evidenced that there is a 61.53% of the amount of human resources needed to carry out the maintenance actions.

  10. Nuclear equipment recalsification based on the service experience

    International Nuclear Information System (INIS)

    Geambasu, A.; Segarceanu, D.

    2000-01-01

    The paper presents some considerations concerning the need of comparison between equipment performance proven by test and the service experience in Cernavoda Nuclear Plant. Service performance dana obtain partly from service failures (failures times) and partly from service experience without failure (running times) can be statistically analyzed to obtain predictions of the number of failures of unfailed units in specified period of time, means time to first failure, means time of median failure, a.s.o. These informations can be used during the operation of Nuclear Power Plant to estimate when a equipment should be replaced with a new one in order to prevent getting to the life end point. (author)

  11. Mechanical design and fabrication of a heat exchanger. Report of the design and construction of a heat exchanger which will be used in 'Experimental analysis of heat transfer in the boiling in forced convection

    International Nuclear Information System (INIS)

    Mariano H, E.

    1991-08-01

    To continue with the equipment of the thermal hydraulics laboratory, it was designed thermal and mechanically an heat exchanger, to satisfy the requirements to have circuit that allows to carry out heat transfer experiments. The heat exchanger was manufactured and proven in the workshops of the Prototypes and Models Management, and it is expected that to obtain the foreseen results once completely installed the circuit, in the laboratory of thermal hydraulics of the Management of Nuclear Systems. (Author)

  12. In-service examination of IHX tubing with eddy current NDT equipment

    International Nuclear Information System (INIS)

    Brown, R.L.

    1972-01-01

    Single and multiple frequency eddy current (ET) nondestructive testing (NDT) techniques and equipment were investigated for in-service inspection of sodium-contaminated intermediate heat exchanger (IHX) tubing. A four frequency technique, demonstrated in the laboratory, was relatively insensitive to signals caused by probe motion, tube support plates, and residual sodium on the outer surface of the tubes. No method was found to avoid the signals from residual sodium on the inside surfaces of the tube. (U.S.)

  13. Major heat exchanger performance in Ontario Hydro-operated CANDU nuclear generating stations

    International Nuclear Information System (INIS)

    Dueck, D.G.

    1980-01-01

    The performance of heat exchangers is described in terms of their impact on the unit in the form of forced outages and deratings as well as incapability due to scheduled outages. Some major problems with heat exchangers are highlighted. (auth)

  14. Optimizing the Heat Exchanger Network of a Steam Reforming System

    DEFF Research Database (Denmark)

    Nielsen, Mads Pagh; Korsgaard, Anders Risum; Kær, Søren Knudsen

    2004-01-01

    Proton Exchange Membrane (PEM) based combined heat and power production systems are highly integrated energy systems. They may include a hydrogen production system and fuel cell stacks along with post combustion units optionally coupled with gas turbines. The considered system is based on a natural...... stationary numerical system model was used and process integration techniques for optimizing the heat exchanger network for the reforming unit are proposed. Objective is to minimize the system cost. Keywords: Fuel cells; Steam Reforming; Heat Exchanger Network (HEN) Synthesis; MINLP....... gas steam reformer along with gas purification reactors to generate clean hydrogen suited for a PEM stack. The temperatures in the various reactors in the fuel processing system vary from around 1000°C to the stack temperature at 80°C. Furthermore, external heating must be supplied to the endothermic...

  15. Nitrate and Perchlorate removal from groundwater by ion exchange; TOPICAL

    International Nuclear Information System (INIS)

    Burge, S; Halden, R

    1999-01-01

    This study was conducted to evaluate the performance of a small scale ion exchange unit (Krudico, Inc of Auborn, IA) for removal of nitrate and perchlorate from groundwater at Lawrence Livermore National Laboratory's Site 300. The unit was able to treat 3,600 gallons of Site 300 groundwater, at an average influent concentration of 100 mg/L NO(sub 3)(sup -) before breakthrough occurred. The unit contained 2.5 ft(sup 3) of Sybron SR-7 resin. Seventy gallons of regeneration waste were generated (water treated to waste ratio of 51:1). The effluent concentration was about 20 mg/L NO(sub 3)(sup -), which is equivalent to a treatment efficiency of at least 80%. There are several options for implementing this technology at Site 300. A target well, in the 817 area, has been selected. It has a 3 to 4 gpm flow rate, and concentrations of 90 mg/L NO(sub 3)(sup -) and 40(micro)g/L perchlorate. The different treatment options include ion exchange treatment of nitrate only, nitrate and perchlorate, or perchlorate only. Option 1: For the treatment of nitrate only, this unit will be able to treat 3,700 gallons of water before regeneration is required. If both columns of the ion exchange unit are used, 7,400 gallons could be treated before the columns will need to be regenerated (producing 140 gallons of waste, per cycle or every 1.5 days). The effluent nitrate concentration is expected to be about 17 mg/L. Annual operation and maintenance costs are estimated to be$0.14 per gallon of water treated. Option 2: If only perchlorate is to be removed with ion exchange at the 817 area, a smaller unit should be considered. A 55 gallon canister filled with ion exchange resin should be able to reduce perchlorate concentrations in the groundwater from 40(micro)g/L to non-detect levels for three years before the resin would need to be replaced. The contaminant-laden resin would be disposed of as hazardous waste. It is not practical to regenerate the resin because of the extreme difficulty of

  16. FY 2000 Report on the survey results. Survey on international cooperation for medical treatment/welfare equipment; 2000 nendo iryo fukushi kiki kokusai kyodo kenkyu jigyo chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The NEDO's representatives visited Europe and China with the objectives of, e.g., international cooperation and information exchanges for medical treatment/welfare equipment. For the welfare equipment technologies, they visited the research institutes and facilities in UK and Germany, among others, to find that the European countries place more emphasis on researches to meet the needs than on advancing the equipment itself. For the medical treatment equipment, they visited the bio-research institutes in Europe for exchanging information on post-genome and tissue engineering. The European countries are behind USA in research fund and manpower for bio-technology and bio-medical, although making great efforts with much expectation on these areas. The China's medical treatment/welfare technologies seem to be clearly still in the stage of needing aids rather than rendering cooperation. However, China has been producing a number of new products in the areas where her traditional arts of medicine are combined with advanced techniques of the West, e.g., those for examination, as felt from a number of the equipment types presented to the China Medical Treatment Equipment Exhibition. (NEDO)

  17. Recent developments in the United Kingdom in ion implantation equipment for engineering components

    International Nuclear Information System (INIS)

    Gardner, P.R.

    1988-01-01

    Harwell has been particularly active in the development and commercial exploitation of low-cost, rugged, reliable and simple-to-operate equipment for implantation of engineering components with gaseous ions, especially nitrogen. Laboratory experiments show this to reduce mild abrasive wear in a wide range of materials by factors typically 2-10, provided operating temperatures remain below about 400 deg C. The latest nitrogen ion implantation machine (the Tecvac 221 model) embodies a substantial degree of flexibility, with cable-mounted ion sources and demountable target chambers. This enables wide ranges of workpiece size and shape to be accommodated. The latest development at Harwell is the large 'Blue Tank' ion implantation machine, currently the biggest in the world. This can treat workpieces up to 2 metres maximum dimension and 1 tonne weight using a bucket-type ion source capable of generating 35 mA of nitrogen ion beam current over an 800 mm diameter treatment area. This machine enables increased flexibility and reduced unit treatment costs for nitrogen ion implantation. Uptake of nitrogen ion implantation in British industry is increasing steadily. Key market sectors include the plastics processing industry (for extrusion screws, moulds and dies), as well as many other engineering sectors. A useful accessory to ion implantation developed at Harwell in conjunction with Millspin Limited, monitors nitrogen ion dose colour changes in anodised tantalum which can be compared against a calibrated standard. Accuracies of around 20 % at 2.5 x 10 17 nitrogen ions.cm -2 dose are achievable. (J.P.N.)

  18. 77 FR 35310 - Revisions to the Export Administration Regulations (EAR): Control of Military Training Equipment...

    Science.gov (United States)

    2012-06-13

    ... for foreign made ``military commodities'' that incorporate more than 10% U.S.-origin ``600 series... Military Training Equipment and Related Items the President Determines No Longer Warrant Control Under the... longer warrant control under Category IX (Military Training Equipment and Training) of the United States...

  19. Exchange Reactions. Proceedings of the Symposium on Exchange Reactions

    International Nuclear Information System (INIS)

    1965-01-01

    The mechanisms and kinetics of chemical reactions are of great interest to chemists. The study of exchange reactions in particular helps to shed light on the dynamics of chemical change, providing an insight into the structures and the reactivities of the chemical species involved. The main theme of this meeting was the subject of oxidation-reduction reactions in which the net result is the transfer of one or more electrons between the different oxidation states of the same element. Other studies reported included the transfer of protons, atoms, complex ligands or organic radicals between molecules. Heterogeneous exchange, which is of importance in many cases of catalytic action, was also considered. For a long time isotopic tracers have formed the most convenient means of studying exchange reactions and today a considerable amount of work continues to be done with their aid. Consequently, several papers presented at this Symposium reported on work carried out by purely radiochemical tracer methods. In recognition, however, of the important role which nuclear magnetic resonance and electron spin resonance play in this field, in particular in the study of fast reactions, a number of reports on investigations in which these techniques had been used was included in the programme. By kind invitation of the United States Government the Symposium on Exchange Reactions was held from 31 May to 4 June at the Brookhaven National Laboratory, Upton, Long Island, N.Y., USA. It was attended by 46 participants from nine countries and one inter-governmental organization. The publication of these Proceedings makes the contents of the papers and the discussion available to a wider audience

  20. Drilling unit

    Energy Technology Data Exchange (ETDEWEB)

    Umanchik, N P; Demin, A V; Khrustalev, N N; Linnik, G N; Lovchev, S V; Rozin, M M; Sidorov, R V; Sokolov, S I; Tsaregradskiy, Yu P

    1981-01-01

    A drilling unit is proposed which includes a hydraulic lifter, hydraulic multiple-cylinder pump with valve distribution and sectional drilling pump with separators of the working and flushing fluid. In order to reduce metal consumption and the overall dimensions of the drilling unit, the working cavity of each cylinder of the hydraulic multiple-cylinder pump is equipped with suction and injection valves and is hydraulically connected to the working cavity by one of the sections of the drilling pump.

  1. Waste separation and pretreatment using crystalline silicotitanate ion exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Tadros, M.E.; Miller, J.E. [Sandia National Lab., Albuquerque, NM (United States); Anthony, R.G. [Texas A& M Univ., College Station, TX (United States)

    1997-10-01

    A new class of inorganic ion exchangers called crystalline silicotitanates (CSTs) has been developed jointly by Sandia National Laboratories and Texas A&M University to selectively remove Cs and other radionuclides from a wide spectrum of radioactive defense wastes. The CST exhibits high selectivity and affinity for Cs and Sr under a wide range of conditions. Tests show it can remove part-per-million concentrations of Cs{sup +} from highly alkaline, high-sodium simulated radioactive waste solutions modeled after those at Hanford, Oak Ridge, and Savannah River. The materials exhibit ion exchange properties based on ionic size selectivity. Specifically, crystalline lattice spacing is controlled to be highly selective for Cs ions even in waste streams containing very high (5 to 10 M) concentrations of sodium. The CST technology is being demonstrated with actual waste at several DOE facilities. The use of inorganic ion exchangers. The inorganics are more resistant to chemical, thermal, and radiation degradation. Their high selectivities result in more efficient operations offering the possibility of a simple single-pass operation. In contrast, regenerable organic ion exchangers require additional processing equipment to handle the regeneration liquids and the eluant with the dissolved Cs.

  2. Experimental Evaluation of a Total Heat Recovery Unit with Polymer Membrane Foils

    DEFF Research Database (Denmark)

    Fang, Lei; Yuan, Shu; Nie, Jinzhe

    2014-01-01

    A laboratory experimental study was conducted to investigate the energy performance of a total heat recovery unit using a polymer membranes heat exchanger. The study was conducted in twin climate chambers. One of the chambers simulated outdoor climate conditions and the other simulated the climate...... condition indoors. The airflows taken from the two chambers were connected into the total heat recovery unit and exchange heat in a polymer membrane foil heat exchanger installed inside the unit. The temperature and humidity of the air upstream and downstream of the heat exchanger were measured. Based...... on the measured temperature and humidity values, the temperature, humidity, and enthalpy efficiencies of the total heat recovery unit were calculated. The experiment was conducted in different combinations of outdoor climate conditions simulating warm and humid outdoor climates and air-conditioned indoor climate...

  3. Causes and Results of Exchange Rate Intervention Under Inflation Targeting

    Directory of Open Access Journals (Sweden)

    Bora Suslu

    2012-06-01

    Full Text Available Under inflation targeting, central banks exchange rate interventions are discussed frequently in the economic literature recently. Effectiveness of intervention in exchange rate under inflation targeting are examined from three perspectives. These are expectations of the actors and the impact on the variance, reserve accumulation and the cost of sterilization. Since 2003 the Central Bank of Turkey has intervened exchange rate with both direct and indirect methods. The purpose of this study is to examine the results of these three aspects of the CBRT and the foreign exchange interventions. We found that by logit analysis under the inflation targeting of CBRT as a result of the intervention of exchange rate is effect expectations of economic unit and reduce of exchange rate the variance; after thes intervention the variance of exchange rate and cost of sterilization are increased. In this respect, the effectiveness of the intervention of the Central Bank exchange rate market is only reserve accumulation

  4. Universal model for water costs of gas exchange by animals and plants

    OpenAIRE

    Woods, H. Arthur; Smith, Jennifer N.

    2010-01-01

    For terrestrial animals and plants, a fundamental cost of living is water vapor lost to the atmosphere during exchange of metabolic gases. Here, by bringing together previously developed models for specific taxa, we integrate properties common to all terrestrial gas exchangers into a universal model of water loss. The model predicts that water loss scales to gas exchange with an exponent of 1 and that the amount of water lost per unit of gas exchanged depends on several factors: the surface t...

  5. Perspectives for utilization of the experience from the electrical equipment modernization of Kozloduy NPP units 5 and 6 in case of construction of new NPP

    International Nuclear Information System (INIS)

    Bogdanov, D.

    2005-01-01

    In 2005 a governmental decision for continue the project for construction of Belene NPP was adopted. In case of start of this significant project in short terms, a good option will be to utilize the already achieved experience by the modernization program of units 5 and 6 of Kozloduy NPP. The process of construction of new NPP is associated with significant amount of engineering, civil construction works, equipment order and delivery, installation works, testing and commissioning activities. It is vital necessity to have optimal technology, strict organization for project implementation and excellent documentation. From technical point of view the experience from the modernization of units 5 and 6 of Kozloduy NPP will be very important in case of utilization of similar types of WWER 1000 units. According to the 'Feasibility study for construction of Belene NPP', the most favorable option is to accomplish the already partially constructed Unit 1 on the basis of upgraded WWER B-320 design - WWER 1000 B-392, in order to fulfill IEC 331-3A, IEC 332-3A, and of US NRC Regulatory Guide 1.70 and to construct the second unit on the basis of ASE WWER/1000 B-466. However, for any type of unit selected, the achieved experience will be an important basis. This article is focused mostly on the modernization aspects of some electrical systems of Kozloduy NPP

  6. Code of Practice for Protection Against Ionizing Radiation Emitted from X-ray Analysis Equipment (1984)

    International Nuclear Information System (INIS)

    1984-01-01

    Appropriate working rules, safety features and monitoring requirements for general X-ray analysis units or equipment are laid down in this Code which is intended for users of such equipment. The Code advises that establishments draw up their own working procedures based on appropriate legislation and on the recommendations contained in this Code. The Code also describes the requirements for X-ray analysis equipment necessary to ensure safety. (NEA) [fr

  7. Root cause analysis underscores the importance of understanding, addressing, and communicating cold chain equipment failures to improve equipment performance.

    Science.gov (United States)

    Lennon, Pat; Atuhaire, Brian; Yavari, Shahrzad; Sampath, Vidya; Mvundura, Mercy; Ramanathan, Nithya; Robertson, Joanie

    2017-04-19

    Vaccine cold chain equipment (CCE) in developing countries is often exposed to harsh environmental conditions, such as extreme temperatures and humidity, and is subject to many additional challenges, including intermittent power supply, insufficient maintenance capacity, and a scarcity of replacement parts. Together, these challenges lead to high failure rates for refrigerators, potentially damaging vaccines and adversely affecting immunization coverage. Providing a sustainable solution for improving CCE performance requires an understanding of the root causes of failure. Project teams conducted small-scale studies to determine the root causes of CCE failure in selected locations in Uganda and Mozambique. The evaluations covered 59 failed refrigerators and freezers in Uganda and 27 refrigerators in Mozambique. In Uganda, the vast majority of failures were due to a cooling unit fault in one widely used refrigerator model. In Mozambique, 11 of the 27 problems were attributable to solar refrigerators with batteries that were unable to hold a charge, and another eight problems were associated with a need to adjust thermostat settings. The studies showed that tracking and evaluation of equipment performance and failure can yield important, actionable information for a range of stakeholders, including local CCE technicians, the ministry of health, equipment manufacturers, and international partners such as the United Nations Children's Fund, World Health Organization, and Gavi, the Vaccine Alliance. Collaborative efforts to systematically collect and communicate data on CCE performance and causes of failure will help to improve the efficiency and reach of immunization programs in low- and middle-income countries. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  8. Heat exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Harada, F; Yanagida, T; Fujie, K; Futawatari, H

    1975-04-30

    The purpose of this construction is the improvement of heat transfer in finned tube heat exchangers, and therefore the improvement of its efficiency or its output per unit volume. This is achieved by preventing the formation of flow boundary layers in gaseous fluid. This effect always occurs on flow of smooth adjacent laminae, and especially if these have pipes carrying liquid passing through them; it worsens the heat transfer of such a boundary layer considerably compared to that in the turbulent range. The fins, which have several rows of heat exchange tubes passing through them, are fixed at a small spacing on theses tubes. The fins have slots cut in them by pressing or punching, where the pressed-out material remains as a web, which runs parallel to the level of the fin and at a small distance from it. These webs and slots are arranged radially around every tube hole, e.g. 6 in number. For a suitable small tube spacing, two adjacent tubes opposite each other have one common slot. Many variants of such slot arrangements are illustrated.

  9. 26 CFR 1.1031(a)-2 - Additional rules for exchanges of personal property.

    Science.gov (United States)

    2010-04-01

    ... furniture, fixtures, and equipment (asset class 00.11), (ii) Information systems (computers and peripheral... product class within Sectors 31, 32, and 33 (pertaining to manufacturing industries) of the North American... the nonrecognition rules of section 1031 do not apply to an exchange of one kind or class of property...

  10. Thermal performance modeling of cross-flow heat exchangers

    CERN Document Server

    Cabezas-Gómez, Luben; Saíz-Jabardo, José Maria

    2014-01-01

    This monograph introduces a numerical computational methodology for thermal performance modeling of cross-flow heat exchangers, with applications in chemical, refrigeration and automobile industries. This methodology allows obtaining effectiveness-number of transfer units (e-NTU) data and has been used for simulating several standard and complex flow arrangements configurations of cross-flow heat exchangers. Simulated results have been validated through comparisons with results from available exact and approximate analytical solutions. Very accurate results have been obtained over wide ranges

  11. A Multiagent Energy Management System for a Small Microgrid Equipped with Power Sources and Energy Storage Units

    Science.gov (United States)

    Radziszewska, Weronika; Nahorski, Zbigniew

    An Energy Management System (EMS) for a small microgrid is presented, with both demand and production side management. The microgrid is equipped with renewable and controllable power sources (like a micro gas turbine), energy storage units (batteries and flywheels). Energy load is partially scheduled to avoid extreme peaks of power demand and to possibly match forecasted energy supply from the renewable power sources. To balance the energy in the network on line, a multiagent system is used. Intelligent agents of each device are proactively acting towards balancing the energy in the network, and at the same time optimizing the cost of operation of the whole system. A semi-market mechanism is used to match a demand and a production of the energy. Simulations show that the time of reaching a balanced state does not exceed 1 s, which is fast enough to let execute proper balancing actions, e.g. change an operating point of a controllable energy source. Simulators of sources and consumption devices were implemented in order to carry out exhaustive tests.

  12. South Africa and United States stock prices and the Rand/Dollar exchange rate

    Directory of Open Access Journals (Sweden)

    Matthew Ocran

    2010-09-01

    Full Text Available This paper seeks to examine the dynamic causal relations between the two major financial assets, stock prices of the US and South Africa and the rand/US$ exchange rate. The study uses a mixed bag of time series approaches such as cointegration, Granger causality, impulse response functions and forecasting error variance decompositions.  The paper identifies a bi-directional causality from the Standard & Poor’s 500 stock price index to the rand/US$ exchange rate in the Granger sense. It was also found that the Standard & Poor’s stock price index accounts for a significant portion of the variations in the Johannesburg Stock Exchange’s All Share index. Thus, while causality in the Granger sense could not be established for the relationship between the price indices of the two stock exchanges it can argued that there is some relationship between them. The results of the study have implications for both business and Government.

  13. EXCHANGE-RATES FORECASTING: EXPONENTIAL SMOOTHING TECHNIQUES AND ARIMA MODELS

    Directory of Open Access Journals (Sweden)

    Dezsi Eva

    2011-07-01

    Full Text Available Exchange rates forecasting is, and has been a challenging task in finance. Statistical and econometrical models are widely used in analysis and forecasting of foreign exchange rates. This paper investigates the behavior of daily exchange rates of the Romanian Leu against the Euro, United States Dollar, British Pound, Japanese Yen, Chinese Renminbi and the Russian Ruble. Smoothing techniques are generated and compared with each other. These models include the Simple Exponential Smoothing technique, as the Double Exponential Smoothing technique, the Simple Holt-Winters, the Additive Holt-Winters, namely the Autoregressive Integrated Moving Average model.

  14. Equipment and techniques developed for the repair of reactor standpipes

    International Nuclear Information System (INIS)

    Hartnell, P.; Kirton-Darling, H.F.R.; Walton, D.N.

    1993-01-01

    In-service cracks had developed in welds in the fabrication at the bottom of the standpipe liner at Hinkley Point-B and Hunterston-B reactors. A joint team investigating these cracks determined that the hot gas flow patterns in the plug unit to standpipe liner annulus were unstable. This had led to thermal stressing and consequent cracking of the standpipe liner welds. In developing a solution consideration was to be given to access down the standpipe for equipment, ambient temperatures, radiation levels and safety considerations. The procedures and equipment developed are described. (author)

  15. Problems of radiation protection at medical use of radiation equipment

    International Nuclear Information System (INIS)

    Larwin, K.

    1979-01-01

    For medical use of radiation equipment man is not only operator, but also object (patient). The question, if or how much it is necessary to expose the patient, is a medical problem and therefore not to be discussed here. For the user of medical equipments we have often special conditions. For many diagnostic applications the physician has to stay in the application room in contact with the patient. As a typical example for the problems of radiation protection there is discussed the situation on a well known fluoroscopic unit for lung and stomach examinations. (author)

  16. Lung Structure and the Intrinsic Challenges of Gas Exchange.

    Science.gov (United States)

    Hsia, Connie C W; Hyde, Dallas M; Weibel, Ewald R

    2016-03-15

    Structural and functional complexities of the mammalian lung evolved to meet a unique set of challenges, namely, the provision of efficient delivery of inspired air to all lung units within a confined thoracic space, to build a large gas exchange surface associated with minimal barrier thickness and a microvascular network to accommodate the entire right ventricular cardiac output while withstanding cyclic mechanical stresses that increase several folds from rest to exercise. Intricate regulatory mechanisms at every level ensure that the dynamic capacities of ventilation, perfusion, diffusion, and chemical binding to hemoglobin are commensurate with usual metabolic demands and periodic extreme needs for activity and survival. This article reviews the structural design of mammalian and human lung, its functional challenges, limitations, and potential for adaptation. We discuss (i) the evolutionary origin of alveolar lungs and its advantages and compromises, (ii) structural determinants of alveolar gas exchange, including architecture of conducting bronchovascular trees that converge in gas exchange units, (iii) the challenges of matching ventilation, perfusion, and diffusion and tissue-erythrocyte and thoracopulmonary interactions. The notion of erythrocytes as an integral component of the gas exchanger is emphasized. We further discuss the signals, sources, and limits of structural plasticity of the lung in alveolar hypoxia and following a loss of lung units, and the promise and caveats of interventions aimed at augmenting endogenous adaptive responses. Our objective is to understand how individual components are matched at multiple levels to optimize organ function in the face of physiological demands or pathological constraints. Copyright © 2016 John Wiley & Sons, Inc.

  17. Lung Structure and the Intrinsic Challenges of Gas Exchange

    Science.gov (United States)

    Hsia, Connie C.W.; Hyde, Dallas M.; Weibel, Ewald R.

    2016-01-01

    Structural and functional complexities of the mammalian lung evolved to meet a unique set of challenges, namely, the provision of efficient delivery of inspired air to all lung units within a confined thoracic space, to build a large gas exchange surface associated with minimal barrier thickness and a microvascular network to accommodate the entire right ventricular cardiac output while withstanding cyclic mechanical stresses that increase several folds from rest to exercise. Intricate regulatory mechanisms at every level ensure that the dynamic capacities of ventilation, perfusion, diffusion, and chemical binding to hemoglobin are commensurate with usual metabolic demands and periodic extreme needs for activity and survival. This article reviews the structural design of mammalian and human lung, its functional challenges, limitations, and potential for adaptation. We discuss (i) the evolutionary origin of alveolar lungs and its advantages and compromises, (ii) structural determinants of alveolar gas exchange, including architecture of conducting bronchovascular trees that converge in gas exchange units, (iii) the challenges of matching ventilation, perfusion, and diffusion and tissue-erythrocyte and thoracopulmonary interactions. The notion of erythrocytes as an integral component of the gas exchanger is emphasized. We further discuss the signals, sources, and limits of structural plasticity of the lung in alveolar hypoxia and following a loss of lung units, and the promise and caveats of interventions aimed at augmenting endogenous adaptive responses. Our objective is to understand how individual components are matched at multiple levels to optimize organ function in the face of physiological demands or pathological constraints. PMID:27065169

  18. Experimental Investigation of Double Effect Evaporative Cooling Unit

    Directory of Open Access Journals (Sweden)

    Ahmed Abd Mohammad Saleh

    2018-03-01

    Full Text Available This work presents the experimental investigation of double effect evaporative cooling unit with approximate capacity 7 kW. The unit consisted of two stages, the sensible heat exchanger and the cooling tower composing the external indirect regenerative evaporative cooling stage where a direct evaporative cooler represent the second stage. Testing results showed a maximum capacity and lowest supplied air temperature when the water flow rate in heat exchanger was 0.1 L/s. The experiment recorded the unit daily readings at two airflow rates (0.425 m3/s, 0.48 m3/s. The reading shows that unit inlet DBT is effect positively on unit wet bulb effectiveness and unit COP at constant humidity ratio. The air extraction ratio effected positively on the unit wet bulb effectiveness within a certain limit where maximum COP recorded 11.4 when the extraction ratio equal to 40%.

  19. Explosion Clad for Upstream Oil and Gas Equipment

    Science.gov (United States)

    Banker, John G.; Massarello, Jack; Pauly, Stephane

    2011-01-01

    Today's upstream oil and gas facilities frequently involve the combination of high pressures, high temperatures, and highly corrosive environments, requiring equipment that is thick wall, corrosion resistant, and cost effective. When significant concentrations of CO2 and/or H2S and/or chlorides are present, corrosion resistant alloys (CRA) can become the material of choice for separator equipment, piping, related components, and line pipe. They can provide reliable resistance to both corrosion and hydrogen embrittlement. For these applications, the more commonly used CRA's are 316L, 317L and duplex stainless steels, alloy 825 and alloy 625, dependent upon the application and the severity of the environment. Titanium is also an exceptional choice from the technical perspective, but is less commonly used except for heat exchangers. Explosion clad offers significant savings by providing a relatively thin corrosion resistant alloy on the surface metallurgically bonded to a thick, lower cost, steel substrate for the pressure containment. Developed and industrialized in the 1960's the explosion cladding technology can be used for cladding the more commonly used nickel based and stainless steel CRA's as well as titanium. It has many years of proven experience as a reliable and highly robust clad manufacturing process. The unique cold welding characteristics of explosion cladding reduce problems of alloy sensitization and dissimilar metal incompatibility. Explosion clad materials have been used extensively in both upstream and downstream oil, gas and petrochemical facilities for well over 40 years. The explosion clad equipment has demonstrated excellent resistance to corrosion, embrittlement and disbonding. Factors critical to insure reliable clad manufacture and equipment design and fabrication are addressed.

  20. Explosion Clad for Upstream Oil and Gas Equipment

    International Nuclear Information System (INIS)

    Banker, John G.; Massarello, Jack; Pauly, Stephane

    2011-01-01

    Today's upstream oil and gas facilities frequently involve the combination of high pressures, high temperatures, and highly corrosive environments, requiring equipment that is thick wall, corrosion resistant, and cost effective. When significant concentrations of CO 2 and/or H 2 S and/or chlorides are present, corrosion resistant alloys (CRA) can become the material of choice for separator equipment, piping, related components, and line pipe. They can provide reliable resistance to both corrosion and hydrogen embrittlement. For these applications, the more commonly used CRA's are 316L, 317L and duplex stainless steels, alloy 825 and alloy 625, dependent upon the application and the severity of the environment. Titanium is also an exceptional choice from the technical perspective, but is less commonly used except for heat exchangers. Explosion clad offers significant savings by providing a relatively thin corrosion resistant alloy on the surface metallurgically bonded to a thick, lower cost, steel substrate for the pressure containment. Developed and industrialized in the 1960's the explosion cladding technology can be used for cladding the more commonly used nickel based and stainless steel CRA's as well as titanium. It has many years of proven experience as a reliable and highly robust clad manufacturing process. The unique cold welding characteristics of explosion cladding reduce problems of alloy sensitization and dissimilar metal incompatibility. Explosion clad materials have been used extensively in both upstream and downstream oil, gas and petrochemical facilities for well over 40 years. The explosion clad equipment has demonstrated excellent resistance to corrosion, embrittlement and disbonding. Factors critical to insure reliable clad manufacture and equipment design and fabrication are addressed.

  1. Computational model and performance optimization methodology of a compact design heat exchanger used as an IHX in HTGR; Modelo computacional y metodologia de optimizacion del funcionamiento de un intercambiador de calor de diseno compacto empleado como IHX en HTGR

    Energy Technology Data Exchange (ETDEWEB)

    De la Torre V, R.; Francois L, J. L., E-mail: delatorrevaldes@gmail.com [UNAM, Facultad de Ingenieria, Departamento de Sistemas Energeticos, Ciudad Universitaria, Circuito Exterior s/n, 04510 Ciudad de Mexico (Mexico)

    2017-09-15

    The intermediate heat exchangers (IHX) present in high-temperature gas-cooled reactor (HTGR) present complex operating conditions, characterized by temperature values higher than 1073 K. Conventional designs of tubes and shell have shown disadvantages with respect to compact designs. In this work, computational models of a compact heat exchanger design, the printed circuit, were built under IHX conditions in a HTGR installation. In these models, a detailed geometry was considered in three dimensions, corresponding to a transfer unit of the heat exchanger. Computational fluid dynamics techniques and finite element methods were used to study the thermo-hydraulic and mechanical functioning of the equipment, respectively. The properties of the materials were defined as temperature functions. The thermo-hydraulic results obtained were established as operating conditions in the structural calculations. A methodology was developed based on the analysis of capital and operating costs, which takes into account the heat transfer, pressure drop and the mechanical behavior of the structure, in a single optimization variable. By analyzing the experimental results of other authors, a relationship was obtained between the operation time of the equipment and the maximum effort in the structure, which was used in the model. The results show that the model that allows a greater thermal efficiency differs from the one that has lower total cost per year. (Author)

  2. An Exponential Increase in Regional Health Information Exchange With Collaborative Policies and Technologies.

    Science.gov (United States)

    Downing, N Lance; Lane, Steven; Eisenberg, Mathew; Sharp, Christopher; Palma, Jonathan; Longhurst, Christopher

    2015-01-01

    In the United States, the ability to securely exchange health information between organization has been limited by technical interoperability, patient identity matching, and variable institutional policies. Here, we examine the regional experience in a national health information exchange network by examining clinical data sharing between eleven Northern California organizations using the same health information exchange (HIE) platform between 2013-2014. We identify key policies and technologies that have led to a dramatic increase in health information exchange.

  3. Generation of equipment response spectrum considering equipment-structure interaction

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Yoo, Kwang Hoon

    2005-01-01

    Floor response spectra for dynamic response of subsystem such as equipment, or piping in nuclear power plant are usually generated without considering dynamic interaction between main structure and subsystem. Since the dynamic structural response generally has the narrow-banded shapes, the resulting floor response spectra developed for various locations in the structure usually have high spectral peak amplitudes in the narrow frequency bands corresponding to the natural frequencies of the structural system. The application of such spectra for design of subsystems often leads to excessive design conservatisms, especially when the equipment frequency and structure are at resonance condition. Thus, in order to provide a rational and realistic design input for dynamic analysis and design of equipment, dynamic equipment-structure interaction (ESI) should be considered in developing equipment response spectrum which is particularly important for equipment at the resonance condition. Many analytical methods have been proposed in the past for developing equipment response spectra considering ESI. However, most of these methods have not been adapted to the practical applications because of either the complexities or the lack of rigorousness of the methods. At one hand, mass ratio among the equipment and structure was used as an important parameter to obtain equipment response spectra. Similarly, Tseng has also proposed the analytical method for developing equipment response spectra using mass ratio in the frequency domain. This method is analytically rigorous and can be easily validated. It is based on the dynamic substructuring method as applied to the dynamic soil-structure interaction (SSI) analysis, and can relatively easily be implemented for practical applications without to change the current dynamic analysis and design practice for subsystems. The equipment response spectra derived in this study are also based on Tseng's proposed method

  4. An overview of heat exchanger technology in the Canadian nuclear program

    International Nuclear Information System (INIS)

    Carlucci, L.N.; Dalrymple, D.G.; Ko, P.L.; Pathania, R.; Pettigrew, M.I.; Scott, D.A.

    1981-06-01

    This paper provides an overview of the Canadian approach to the reliability and serviceability of heat exchange equipment used in nuclear power stations and heavy water plants. Current work in vibration and fretting predictions, thermal-hydraulic analyses, and corrosion research is described. Procedures developed for in-service inspection, in situ tube replacment and chemical cleaning of corrosion products are also outlined

  5. Application of the Guided Wave Technique to the Heat Exchanger Tube in NPP

    International Nuclear Information System (INIS)

    Yang, Dong Soon; Kim, Hyung Nam; Yoo, Hyun Joo

    2005-01-01

    The heat exchanger tube is examined by the method of eddy current test(ECT) to identify the integrity of the nuclear power plant. Because ECT probe is moved through the tube inside to identify flaws, the ECT probe should be exchanged periodically due to the wear of probe surface in order to remove the noise form the ECT signal. Moreover, it is impossible to examine the tube by ECT method because the ECT probe can not move through the inside due to the deformation such as dent. Recently, the theory of guided wave was established and the equipment applying the theory has been actively developed so as to overcome the limitation of ECT method for the tube inspection of heater exchanger in nuclear power plant. The object of this study is to know the application of the guided wave technique to heat exchanger tube in NPP

  6. Numerical simulation and experimental validation of internal heat exchanger influence on CO{sub 2} trans-critical cycle performance

    Energy Technology Data Exchange (ETDEWEB)

    Rigola, Joaquim; Ablanque, Nicolas; Perez-Segarra, Carlos D.; Oliva, Assensi [Centre Tecnologic de Transferencia de Calor (CTTC), Universitat Politecnica de Catalunya (UPC), ETSEIAT, C. Colom 11, 08222 Terrassa (Barcelona) (Spain)

    2010-06-15

    The present paper is a numerical and experimental comparative study of the whole vapour compression refrigerating cycle in general, and reciprocating compressors in particular, with the aim of showing the possibilities that CO{sub 2} offers for commercial refrigeration, considering a single-stage trans-critical cycle using semi-hermetic reciprocating compressors under small cooling capacity systems. The present work is focussed on the influence of using an internal heat exchanger (IHX) in order to improve the cycle performance under real working conditions. In order to validate the numerical results, an experimental unit specially designed and built to analyze trans-critical refrigerating equipments considering IHX has been built. Both numerical results and experimental data show reasonable good agreement, while the comparative global values conclude the improvement of cooling capacity and COP when IHX is considered in the CO{sub 2} trans-critical cycle. (author)

  7. Maintenance or replacement of primary equipments

    International Nuclear Information System (INIS)

    Branchu, J.

    1995-01-01

    The principal materials, such as the primary equipments of a PWR type steam generator, have a finite service life. Framatome, builder of steam generators and maintenance contractor of Electricite de France has developed a methodology for the maintenance or the replacement of primary equipments. The paper describes the methodology followed by Framatome to identify and localize the wear mode and to treat or repair the component. Four failure modes have been considered: crack propagation, rubbing/vibration wear, neutron irradiation and corrosion propagation under permanent stress. A kinetic modelling of wear propagation has been computerized and validated using mechanical tests on Inconel 600 mockups. These analyses have allow to determine the strategy of repair or replacement of vessel heads for each unit. The method is evaluated taking into account the risk assessment, cost, dosimetry, efficiency and time delay involved. (J.S.). 1 fig., 3 photos

  8. System for routine testing of self-contained and airline breathing equipment

    Energy Technology Data Exchange (ETDEWEB)

    McDermott, H.J.; Hermens, G.A.

    1980-07-01

    A system for routine testing of self-contained and airline breathing equipment, developed by Shell Oil Co., for testing breathing equipment at one of its refineries, consists of an 80 psig air supply for airline respirators; a 500-2100 psig air supply for self-contained units; a regulator test system which uses a mannequin head that simulates human inhalation and which tests the ability of the regulator to keep the mask interior at the correct positive pressure; and an exhalation valve test system which identifies a leaky or sticking valve. The testing system has been in use for about 30 mo and has led to increased acceptance of respiratory protective equipment by workers.

  9. A multiplicity logic unit

    International Nuclear Information System (INIS)

    Bialkowski, J.; Moszynski, M.; Zagorski, A.

    1981-01-01

    The logic diagram principle of operation and some details of the design of the multiplicity logic unit are presented. This unit was specially designed to fulfil the requirements of a multidetector arrangement for gamma-ray multiplicity measurements. The unit is equipped with 16 inputs controlled by a common coincidence gate. It delivers a linear output pulse with the height proportional to the multiplicity of coincidences and logic pulses corresponding to 0, 1, ... up to >= 5-fold coincidences. These last outputs are used to steer the routing unit working with the multichannel analyser. (orig.)

  10. 9 CFR 590.502 - Equipment and utensils; PCB-containing equipment.

    Science.gov (United States)

    2010-01-01

    ... Sanitary Standards and accepted practices currently in effect for such equipment. (c) New or replacement equipment or machinery (including any replacement parts) brought onto the premises of any official plant... equipment and machinery, and any replacement parts for such equipment and machinery. Totally enclosed...

  11. Design and economic optimization of shell and tube heat exchangers using Artificial Bee Colony (ABC) algorithm

    International Nuclear Information System (INIS)

    Sencan Sahin, Arzu; Kilic, Bayram; Kilic, Ulas

    2011-01-01

    Highlights: → Artificial Bee Colony for shell and tube heat exchanger optimization is used. → The total cost is minimized by varying design variables. → This new approach can be applied for optimization of heat exchangers. - Abstract: In this study, a new shell and tube heat exchanger optimization design approach is developed. Artificial Bee Colony (ABC) has been applied to minimize the total cost of the equipment including capital investment and the sum of discounted annual energy expenditures related to pumping of shell and tube heat exchanger by varying various design variables such as tube length, tube outer diameter, pitch size, baffle spacing, etc. Finally, the results are compared to those obtained by literature approaches. The obtained results indicate that Artificial Bee Colony (ABC) algorithm can be successfully applied for optimal design of shell and tube heat exchangers.

  12. Design and economic optimization of shell and tube heat exchangers using Artificial Bee Colony (ABC) algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Sencan Sahin, Arzu, E-mail: sencan@tef.sdu.edu.tr [Department of Mechanical Education, Technical Education Faculty, Sueleyman Demirel University, 32260 Isparta (Turkey); Kilic, Bayram, E-mail: bayramkilic@hotmail.com [Bucak Emin Guelmez Vocational School, Mehmet Akif Ersoy University, Bucak (Turkey); Kilic, Ulas, E-mail: ulaskilic@mehmetakif.edu.tr [Bucak Emin Guelmez Vocational School, Mehmet Akif Ersoy University, Bucak (Turkey)

    2011-10-15

    Highlights: {yields} Artificial Bee Colony for shell and tube heat exchanger optimization is used. {yields} The total cost is minimized by varying design variables. {yields} This new approach can be applied for optimization of heat exchangers. - Abstract: In this study, a new shell and tube heat exchanger optimization design approach is developed. Artificial Bee Colony (ABC) has been applied to minimize the total cost of the equipment including capital investment and the sum of discounted annual energy expenditures related to pumping of shell and tube heat exchanger by varying various design variables such as tube length, tube outer diameter, pitch size, baffle spacing, etc. Finally, the results are compared to those obtained by literature approaches. The obtained results indicate that Artificial Bee Colony (ABC) algorithm can be successfully applied for optimal design of shell and tube heat exchangers.

  13. Characterizing volumetric discontinuities present in NPP heat exchangers with EASY: an eddy current data analysis system

    Energy Technology Data Exchange (ETDEWEB)

    Alencar, Donizete A.; Silva Junior, Silverio F., E-mail: daa@cdtn.b, E-mail: silvasf@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Eddy current is a very important NDT inspection method widely used to perform integrity evaluation of tubes installed in heat exchangers. For nuclear power plants, a classical example is the remote inspection of steam generators and condensers, as well as other ordinary auxiliary equipment. Data evaluation can be performed by means of precise phase and amplitude measurements of complex impedance signals, represented as Lissajous figures plotted on the screen of the inspection systems. This paper presents the software EASY, a computer assisted analysis system developed at CDTN to help the characterization of volumetric discontinuities present in heat exchangers tubes. Data to be analyzed are obtained from commercial eddy current equipment data file, such as ECT MAD8D. Main advantage of that system is its portability and easy use, since it can be executed in ordinary PC, under Microsoft Windows operating system. (author)

  14. Characterizing volumetric discontinuities present in NPP heat exchangers with EASY: an eddy current data analysis system

    International Nuclear Information System (INIS)

    Alencar, Donizete A.; Silva Junior, Silverio F.

    2011-01-01

    Eddy current is a very important NDT inspection method widely used to perform integrity evaluation of tubes installed in heat exchangers. For nuclear power plants, a classical example is the remote inspection of steam generators and condensers, as well as other ordinary auxiliary equipment. Data evaluation can be performed by means of precise phase and amplitude measurements of complex impedance signals, represented as Lissajous figures plotted on the screen of the inspection systems. This paper presents the software EASY, a computer assisted analysis system developed at CDTN to help the characterization of volumetric discontinuities present in heat exchangers tubes. Data to be analyzed are obtained from commercial eddy current equipment data file, such as ECT MAD8D. Main advantage of that system is its portability and easy use, since it can be executed in ordinary PC, under Microsoft Windows operating system. (author)

  15. Compensation of equipment housing elements of reactor units with heavy liquid metal coolant vessel temperature deformations

    International Nuclear Information System (INIS)

    Lebedevich, V.; Ahmetshin, M.; Mendes, D.; Kaveshnikov, S.; Vinogradov, A.

    2015-01-01

    In Russia a lot of different versions of fast reactors (FRs) are investigated and one of these is FR cooled by liquid lead and liquid lead-bismuth alloy. In this poster we are interested by FR with concrete vessel; its components are placed in cavities inside the vessel, and connected by a channel system. During the installation the equipment components are placed in several equipment housings. Between these housings there are cavities with coolant. The alignment of the housings should be provided. It can be broken by irregular concrete vessel heating during FR starting or other transition regimes. Our goal is to suggest a list of designing steps to compensate temperature deformations of equipment housing elements. A simplified model of equipment housing was suggested. It consists of two cylinders - tunnels in the concrete vessel, separated by a cavity filled by coolant and inert gas. The bottom part was considered as heated to 420 C. degrees while in the top part temperature decreased to 45 C. degrees (on the concrete surface). According to this data, results show that temperature gradient leads to a concrete layer dislocation of about 12.5 mm, which can lead to damage and breaking alignment. We propose the following solution to compensate for temperature deformation: -) to chisel out part of the upper top of the insulating concrete; -) to install an adequate misalignment of equipment housing elements preliminary; and -) to use a torsion system like a piston-type device for providing additional strength in order to compensate deformation and vibrations

  16. Equipment considerations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Trace or ultratrace analyses require that the HPLC equipment used, including the detector, be optimal for such determinations. HPLC detectors are discussed at length in Chapter 4; discussion here is limited to the rest of the equipment. In general, commercial equipment is adequate for trace analysis; however, as the authors approach ultratrace analysis, it becomes very important to examine the equipment thoroughly and optimize it, where possible. For this reason they will review the equipment commonly used in HPLC and discuss the optimization steps. Detectability in HPLC is influenced by two factors (1): (a) baseline noise or other interferences that lead to errors in assigning the baseline absorbance; (b) peak width. 87 refs

  17. Electronic equipment. New functional units in NIM standard

    International Nuclear Information System (INIS)

    Cheminaud, J.; Grasso, G.; Lacroix, C.; Le Baud, P.; Pichot, G.; Poirot, L.

    During the year 1974 some new modules have been developed: i) a tele-control for delay-time which utilizes a multiplexer-demultiplexer; ii) a fast pulse generator for light-emitting diodes which allows the test of devices using photomultipliers; iii) a plug-in-unit of variable shaper for fast pulses, with reset and zero dead time; iv) an amplifier with a 50MHz band-pass and an adjusting amplification from 0 to 10; v) a pocket generator delivering NIM pulses [fr

  18. Tactical Mission Command (TMC)

    Science.gov (United States)

    2016-03-01

    and TBMCS . Exchange information with coalition digital C2 systems. Display overlays created by MCS and other ABCS Systems Exchange information...Equipment TBMCS - Theater Battle Management Core Systems USMC - United States Marine Corps WARNO - Warning Order TMC 2016 MAR UNCLASSIFIED 10 Cost

  19. Improved control rod drive handling equipment for BWRs [boiling-water reactors]: Final report

    International Nuclear Information System (INIS)

    Turner, A.P.L.; Gorman, J.A.

    1987-08-01

    Improved equipment for removing and replacing control rod drives (CRDs) in BWR plants has been designed, built and tested. Control rod drives must be removed from the reactor periodically for servicing. Removal and replacement of CRDs using equipment originally supplied with the plant has long been recognized as one of the more difficult and highest radiation exposure maintenance operations that must be performed at BWR plants. The improved equipment was used for the first time at Quad Cities, Unit 2, during a Fall 1986 outage. The trial of the equipment was highly successful, and it was shown that the new equipment significantly improves CRD handling operations. The new equipment significantly simplifies the sequence of operations required to lower a CRD from its housing, upend it to a horizontal orientation, and transport it out of the reactor containment. All operations of the new equipment are performed from the undervessel equipment handling platform, thus, eliminating the requirement for a person to work on the lower level of the undervessel gallery which is often highly contaminated. Typically, one less person is required to operate the equipment than were used with the older equipment. The new equipment incorporates a number of redundant and fail safe features that improve operations and reduce the chances for accidents

  20. 30 CFR 75.1003-2 - Requirements for movement of off-track mining equipment in areas of active workings where...

    Science.gov (United States)

    2010-07-01

    ... moving or transporting operations. (d) The frames of off-track mining equipment being moved or... and the frames of off-track mining equipment being moved in-track and trolley entries, except that... the trolley wires or trolley feeder wires only from outby the unit of equipment being moved or...

  1. Design study of plastic film heat exchanger

    Science.gov (United States)

    Guyer, E. C.; Brownell, D. L.

    1986-02-01

    This report presents the results of an effort to develop and design a unique thermoplastic film heat exchanger for use in an industrial heat pump evaporator system and other energy recovery applications. The concept for the exchanger is that of individual heat exchange elements formed by two adjoining and freely hanging plastic films. Liquid flows downward in a regulated fashion between the films due to the balance of hydrostatic and frictional forces. The fluid stream on the outside of film may be a free-falling liquid film, a condensing gas, or a noncondensing gas. The flow and structural principles are similar to those embodied in an earlier heat exchange system developed for use in waste water treatment systems (Sanderson). The design allows for high heat transfer rates while working within the thermal and structural limitations of thermoplastic materials. The potential of this new heat exchanger design lies in the relatively low cost of plastic film and the high inherent corrosion and fouling resistance. This report addresses the selection of materials, the potential heat transf er performance, the mechanical design and operation of a unit applied in a low pressure steam recovery system, and the expected selling price in comparison to conventional metallic shell and tube heat exchangers.

  2. New equipment for the needs of mobile automatic ultrasonic testing

    International Nuclear Information System (INIS)

    Cost, H.; Vogt, M.

    1989-01-01

    A newly designed system of equipment - ECHOGRAPH 1030 MULTI - for multiplex operation is introduced. The frequency control unit which can distribute a pulse sequency frequency from a maximum of 8 KHz to up to 8 cycles and the monitor evaluation, are described. (MM) [de

  3. The difficult business model for mask equipment makers and mask infrastructure development support from consortia and governments

    Science.gov (United States)

    Hector, Scott

    2005-11-01

    The extension of optical projection lithography through immersion to patterning features with half pitch face the challenge of being profitable in the small market for mask equipment while encountering significant R&D expenses to bring new generations of mask fabrication equipment to market. The total available market for patterned masks is estimated to be $2.5B to $2.9B per year. The patterned mask market is about 20% of the market size for lithography equipment and materials. The total available market for mask-making equipment is estimated to be about $800M per year. The largest R&D affordability issue arises for the makers of equipment for fabricating masks where total available sales are typically less than ten units per year. SEMATECH has used discounted cash flow models to predict the affordable R&D while maintaining industry accepted internal rates of return. The results have been compared to estimates of the total R&D cost to bring a new generation of mask equipment to market for various types of tools. The analysis revealed that affordability of the required R&D is a significant problem for many suppliers of mask-making equipment. Consortia such as SEMATECH and Selete have played an important role in cost sharing selected mask equipment and material development projects. Governments in the United States, in Europe and in Japan have also helped equipment suppliers with support for R&D. This paper summarizes the challenging business model for mask equipment suppliers and highlight government support for mask equipment and materials development.

  4. Seizing market shaping opportunities for vaccine cold chain equipment.

    Science.gov (United States)

    Azimi, Tara; Franzel, Lauren; Probst, Nina

    2017-04-19

    Gavi, the Vaccine Alliance, supports immunisation programmes in eligible countries to reach children with lifesaving vaccines. Dramatic improvement in the scale and performance of current cold chain systems is required to extend the reach of immunisation services - especially for children living in remote locations - to advance progress towards full vaccine coverage. Achieving these improvements will require a healthier market for cold chain equipment where the products meet user needs, are sustainably priced, and are available in sufficient quantities to meet demand. Yet evidence suggests that the cold chain market has suffered from several failures including limited demand visibility, fragmented procurement, and insufficient information exchange between manufacturers and buyers on needs and equipment performance. One of Gavi's strategic goals is to shape markets for vaccines and other immunisation products, including cold chain equipment and in 2015, Gavi created a new mechanism - the Cold Chain Equipment (CCE) Optimisation Platform - to strengthen country cold chain systems by offering financial support and incentives for higher performing CCE. The main objective of the CCE Platform is to get more equipment that is efficient, sustainable, and better performing deployed to every health facility where it is required at an affordable price. To achieve these objectives, Gavi is putting in place tested market shaping approaches and tools adapted for the CCE market: the development of market strategies or 'roadmaps'; improvement of product performance through the development of target product profiles (TPPs); strategic engagement with CCE manufacturers and countries to enhance information sharing; and tailoring procurement tactics to the CCE market. These approaches and tools will allow for increased demand and supply of higher-performing, cost-effective and quality products. By strengthening immunisation systems with improved cold chain equipment, Gavi countries can

  5. Communication of 10 January 2008 received from the Permanent Mission of the United Kingdom regarding the Export of Nuclear Material and of Certain Categories of Equipment and Other Material

    International Nuclear Information System (INIS)

    2008-01-01

    The Director General has received a note ver bale from the Permanent Mission of the United Kingdom, dated 10 January 2008, in which it requests that the Agency circulate to all Member States a letter of 12 December 2006 from the Chairman of the Zangger Committee, Mr. Pavel Klucky, to the Director General, on behalf of the Governments of Argentina, Australia, Austria, Belgium, Bulgaria, Canada, China, Croatia, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Japan, Republic of Korea, Luxemburg, the Netherlands, Norway, Poland, Portugal, Romania, Russian Federation, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Turkey, Ukraine, the United Kingdom of Great Britain and Northern Ireland and the United States of America, concerning the export of nuclear material and of certain categories of equipment and other material [fr

  6. Communication of 10 January 2008 received from the Permanent Mission of the United Kingdom regarding the Export of Nuclear Material and of Certain Categories of Equipment and Other Material

    International Nuclear Information System (INIS)

    2008-01-01

    The Director General has received a note ver bale from the Permanent Mission of the United Kingdom, dated 10 January 2008, in which it requests that the Agency circulate to all Member States a letter of 12 December 2006 from the Chairman of the Zangger Committee, Mr. Pavel Klucky, to the Director General, on behalf of the Governments of Argentina, Australia, Austria, Belgium, Bulgaria, Canada, China, Croatia, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Japan, Republic of Korea, Luxemburg, the Netherlands, Norway, Poland, Portugal, Romania, Russian Federation, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Turkey, Ukraine, the United Kingdom of Great Britain and Northern Ireland and the United States of America, concerning the export of nuclear material and of certain categories of equipment and other material [es

  7. Communication of 10 January 2008 received from the Permanent Mission of the United Kingdom regarding the Export of Nuclear Material and of Certain Categories of Equipment and Other Material

    International Nuclear Information System (INIS)

    2008-01-01

    The Director General has received a note ver bale from the Permanent Mission of the United Kingdom, dated 10 January 2008, in which it requests that the Agency circulate to all Member States a letter of 12 December 2006 from the Chairman of the Zangger Committee, Mr. Pavel Klucky, to the Director General, on behalf of the Governments of Argentina, Australia, Austria, Belgium, Bulgaria, Canada, China, Croatia, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Japan, Republic of Korea, Luxemburg, the Netherlands, Norway, Poland, Portugal, Romania, Russian Federation, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Turkey, Ukraine, the United Kingdom of Great Britain and Northern Ireland and the United States of America, concerning the export of nuclear material and of certain categories of equipment and other material [ru

  8. Communications received from certain Member States regarding guidelines for the export of nuclear material, equipment and technology

    International Nuclear Information System (INIS)

    1992-07-01

    The document reproduces the text of the notes verbales dated 15 May 1992, received by the Director General from the Resident Representatives to the Agency of Australia, Austria, Belgium, Bulgaria, Canada, Czech and Slovak Federal Republic, Denmark, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Japan, Luxembourg, Netherlands, Norway, Poland, Portugal, Romania, Russia Federation, Spain, Sweden, Switzerland, the United Kingdom of Great Britain and Northern Ireland, and the United States of America relating to the export of nuclear material, equipment and technology and the Guidelines for Transfer of Nuclear-Related Dual-Use Equipment, Material and Related Technology. An Annex to these Guidelines contains the list of Nuclear-Related Dual-Use Equipment and Materials and Related Technology

  9. Environmental qualification program of electric equipment for Angra 1

    Energy Technology Data Exchange (ETDEWEB)

    Muzitano, Grazielle F.; Justino, Marcelo C.; Silva, Marcos C., E-mail: grazi@eletronuclear.gov.br, E-mail: justino@eletronuclear.gov.br, E-mail: candeia@eletronuclear.gov.br [Eletrobras Termonuclear S.A. (ELETRONUCLEAR), Rio de Janeiro, RJ (Brazil)

    2017-11-01

    This paper describes the development of the environmental qualification program for important electrical equipment (EQPEE) used for safety in Angra 1 Nuclear Power Plant (NPP). The environmental qualification program started in United States of America by the Nuclear Regulatory Commission (NRC) after the Three Mile Island (TMI) Nuclear Power Plant Accident in 1979. In that event, some equipment installed inside the reactor containment of TMI failed due the harsh conditions that occurred after the accident. Because of this fact, the NRC issued the Regulation 50.49 'Environmental qualification of electric equipment important to safety for nuclear power plants'. The Brazilian regulatory commission CNEN also asked Angra 1 to follow this regulation and to implement an EQPEE similar to the programs adopted by American and other NPPs around the world. Due to the importance to maintain the critical equipment operating in normal and abnormal environment conditions, the program aims to assure that this equipment remains qualified to work under the harsh conditions found inside the reactor containment. The aging of these components are also analyzed in this program that is important in the process to extend the operating life of Angra 1 for more 20 years, which is normally referred as Long Term Operation (LTO). (author)

  10. Environmental qualification program of electric equipment for Angra 1

    International Nuclear Information System (INIS)

    Muzitano, Grazielle F.; Justino, Marcelo C.; Silva, Marcos C.

    2017-01-01

    This paper describes the development of the environmental qualification program for important electrical equipment (EQPEE) used for safety in Angra 1 Nuclear Power Plant (NPP). The environmental qualification program started in United States of America by the Nuclear Regulatory Commission (NRC) after the Three Mile Island (TMI) Nuclear Power Plant Accident in 1979. In that event, some equipment installed inside the reactor containment of TMI failed due the harsh conditions that occurred after the accident. Because of this fact, the NRC issued the Regulation 50.49 'Environmental qualification of electric equipment important to safety for nuclear power plants'. The Brazilian regulatory commission CNEN also asked Angra 1 to follow this regulation and to implement an EQPEE similar to the programs adopted by American and other NPPs around the world. Due to the importance to maintain the critical equipment operating in normal and abnormal environment conditions, the program aims to assure that this equipment remains qualified to work under the harsh conditions found inside the reactor containment. The aging of these components are also analyzed in this program that is important in the process to extend the operating life of Angra 1 for more 20 years, which is normally referred as Long Term Operation (LTO). (author)

  11. Guidelines for heat exchange performance evaluation. A practical and semitheoretical approach

    International Nuclear Information System (INIS)

    Chocron, M.; Urrutia, G.; Calderon, Ma. del C Raffo; Arostegui, E.; Johanssen, W.; Guala, M.

    1998-01-01

    Steam Generators and highly rated heat exchangers, such as feed water preheaters, moderator coolers of PHWRs, etc., are frequently surveyed, as far as heat exchange capability is concerned, by monitoring some of the heat and mass transfer balances variables involved, though they are not necessarily the most proper ones for the best assesment. Through several years' experience working in the engineering department of a Nuclear Power Plant, it can be concluded that every important component or equipment that has an almost unique design due to its importance, requires a particular treatment for its periodical surveillance. In the present paper some guiding rules for a better achievement of the aforementioned task are described and illustrated with examples taken from several plant situations. It can be concluded that, improving process variables measurement, together with data reconciliation and a proper modelling leads to better parameters to survey heat transport in heath exchangers. (author)

  12. Continuous cleaning of heat exchanger with recirculating fluidized bed

    International Nuclear Information System (INIS)

    St Kollbach, J.; Dahm, W.; Rautenbach, R.

    1987-01-01

    Fluidized bed heat exchangers for liquids have been studied in the United States, the Netherlands, and the Federal Republic of Germany. Between 1965 and 1970, fluidized bed heat exchangers were developed in the United States as brine heaters in seawater desalination. Furthermore, their potential in the utilization of geothermal energy was tested between 1975 and 1980. In the Netherlands, fluidized bed heat exchangers have been developed since 1973 for brine heating and heat recovery in multistage flash evaporators for seawater desalination and, since about 1980, for applications in the process industry. The authors became interested in fluidized bed heat exchangers first in 1978 in connection with wastewater evaporation. The authors emphasize that the results of all these groups were in basic agreement. They can be summarized as follows: 1. The fluidized bed will in many cases maintain totally clean surfaces and neither scaling nor fouling will occur. In cases where even a fluidized bed cannot completely prevent scaling or fouling, the thickness of the layer is controlled. In these cases stable operation maintaining acceptable overall heat transfer coefficients is possible without cleaning. 2. There are always excellent heat transfer coefficients as low superficial velocities of less than ν < 0.5 m/s. 3. The pressure losses are comparable with those in normal heat exchangers since fluidized bed heat exchangers are mostly operated at low superficial velocities. 4. Feed flow may be varied between 50 and 150% or more of the design feed flow. 5. Erosion is negligible. 6. Fluidized bed particles can be manufactured from all sorts of chemically and mechanically resistant materials, such as sand, glass, ceramics, and metals

  13. Medical Issues: Equipment

    Science.gov (United States)

    ... Information Packets Equipment Pool Living With SMA Medical Issues Palliative Breathing Orthopedics Nutrition Equipment Daily Life At ... curesma.org > support & care > living with sma > medical issues > equipment Equipment Individuals with SMA often require a ...

  14. YAG laser cladding to heat exchanger flange in actual plant

    International Nuclear Information System (INIS)

    Toshio, Kojima

    2001-01-01

    This paper is a sequel to ''Development of YAG Laser Cladding Technology to Heat Exchanger Flange'' presented in ICONE-8. A YAG Laser cladding technology is a permanent repairing and preventive maintenance method for heat exchanger's flange (channel side) seating surface which is degraded by the corrosion in long term operation. The material of this flange is carbon steel, and that of cladding wire is type 316 stainless steel so as to have high corrosion resistance. In former paper above, the soundness of cladding layers were presented to be verified. This channel side flange is bolted with tube sheet (shell side) through metal gasket. As the tube sheet side is already cladded a corrosion resistant material, it needs to apply the repairing and preventive maintenance method to only channel side. In 2000 this technology had been performed to the actual heat exchanger (Residual Heat Removal Heat Exchanger; RHR Hx) flange in domestic nuclear power plant. This paper described the outline, special equipment, and our total evaluation for this actual laser cladding work. And also several technical subjects which we should solve and/or improve for the next project was presented. (author)

  15. Composition of plastics from waste electrical and electronic equipment (WEEE) by direct sampling

    International Nuclear Information System (INIS)

    Martinho, Graça; Pires, Ana; Saraiva, Luanha; Ribeiro, Rita

    2012-01-01

    Highlights: ► The article shows WEEE plastics characterization from a recycling unit in Portugal. ► The recycling unit has low machinery, with hand sorting of plastics elements. ► Most common polymers are PS, ABS, PC/ABS, HIPS and PP. ► Most plastics found have no identification of plastic type or flame retardants. ► Ecodesign is still not practiced for EEE, with repercussions in end of life stage. - Abstract: This paper describes a direct analysis study carried out in a recycling unit for waste electrical and electronic equipment (WEEE) in Portugal to characterize the plastic constituents of WEEE. Approximately 3400 items, including cooling appliances, small WEEE, printers, copying equipment, central processing units, cathode ray tube (CRT) monitors and CRT televisions were characterized, with the analysis finding around 6000 kg of plastics with several polymer types. The most common polymers are polystyrene, acrylonitrile–butadiene–styrene, polycarbonate blends, high-impact polystyrene and polypropylene. Additives to darken color are common contaminants in these plastics when used in CRT televisions and small WEEE. These additives can make plastic identification difficult, along with missing polymer identification and flame retardant identification marks. These drawbacks contribute to the inefficiency of manual dismantling of WEEE, which is the typical recycling process in Portugal. The information found here can be used to set a baseline for the plastics recycling industry and provide information for ecodesign in electrical and electronic equipment production.

  16. Numerical simulation of heat exchangers elliptical tubes and corrugated fins

    International Nuclear Information System (INIS)

    Borrajo Pérez, Rubén; González Bayón, Juan José; Menéndez Pérez, Alberto

    2015-01-01

    The intensified heat exchangers fins are widely used in the automotive and domestic industry. The low heat transfer coefficients on the air side are the main reason why these fins of heat exchangers need to be intensified. In this paper, the numerical simulation of a wavy fin type is made with elliptical tubes. The dimensions of the fin is in the range of those used in air conditioning equipment. The friction factor and the mass transfer coefficient as a function of the Reynolds number for this type of fin, always within the laminar regime is determined. The numerical model against experimental results published in the literature is validated. In addition the mechanisms that produce intensified heat transfer fin in such occur. (full text)

  17. The gravitational plant physiology facility-Description of equipment developed for biological research in spacelab

    Science.gov (United States)

    Heathcote, D. G.; Chapman, D. K.; Brown, A. H.; Lewis, R. F.

    1994-01-01

    In January 1992, the NASA Suttle mission STS 42 carried a facility designed to perform experiments on plant gravi- and photo-tropic responses. This equipment, the Gravitational Plant Physiology Facility (GPPF) was made up of a number of interconnected units mounted within a Spacelab double rack. The details of these units and the plant growth containers designed for use in GPPF are described. The equipment functioned well during the mission and returned a substantial body of time-lapse video data on plant responses to tropistic stimuli under conditions of orbital microgravity. GPPF is maintained by NASA Ames Research Center, and is flight qualifiable for future spacelab missions.

  18. Preliminary design report for prototypical spent nuclear fuel rod consolidation equipment

    International Nuclear Information System (INIS)

    Judson, B.F.; Maillet, J.; O'Neill, G.L.; Tsitsichvili, J.; Tucoulat, D.

    1986-12-01

    The purpose of the Prototypical Consolidation Demonstration Project (PCDP) is to develop and demonstrate the equipment system that will be used to consolidate the bulk of the spent nuclear fuel generated in the United States prior to its placement in a geological repository. The equipment must thus be capable of operating on a routine production basis over a long period of time with stringent requirements for safety, reliability, productivity and cost-effectiveness. Four phases are planned for the PCDP. Phase 1 is the Preliminary Design of generic consolidation equipment that could be installed at a Monitored Retrievable Storage (MRS) facility or in the Receiving ampersand Handling Facility at a geologic repository site. Phase 2 will be the Final Design and preparation of procurement packages for the equipment in a configuration capable of being installed and tested in a special enclosure within the TAN Hot Shop at DOE's Idaho National Engineering Laboratory. In Phase 3 the equipment will be fabricated and then tested with mock fuel elements in a contractor's facility. Finally, in Phase 4 the equipment will be moved to the TAN facility for demonstration operation with irradiated spent fuel elements. 55 figs., 15 tabs

  19. Catalytic heat exchangers for small-scale production of hydrogen - feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Silversand, F [Catator AB, Lund (Sweden)

    2002-02-01

    A feasibility study concerning heat-exchanger reactors in small-scale production of hydrogen has been performed on the request of Svenskt Gastekniskt Center AB and SWEP International AB. The basic idea is to implement different catalysts into brazed plate-type heat exchangers. This can be achieved by installing catalytic cylinders in the inlet-and outlet ports of the heat exchangers or through treatment of the plates to render them catalytically active. It is also possible to sandwich catalytically active wire meshes between the plates. Experiments concerning steam reforming of methanol and methane have been performed in a micro-reactor to gather kinetic data for modelling purposes. Performance calculations concerning heat exchanger reactors have then been conducted with Catator's generic simulation code for catalytic reactors (CatalystExplorer). The simulations clearly demonstrate the technical performance of these reactors. Indeed, the production rate of hydrogen is expected to be about 10 nm{sup 3}/h per litre of heat exchanger. The corresponding value for a conventional steam-reforming unit is about 1 nm{sup 3}/h or less per litre of reactor volume. Also, the compactness and the high degree of integration together with the possibilities of mass production will give an attractive cost for such units. Depending on the demands concerning the purity of the hydrogen it is possible to add secondary catalytic steps like water-gas shifters, methanation and selective oxidation, into a one-train unit, i.e. to design an all-inclusive design. Such reactors can be used for the supply of hydrogen to fuel cells. The production cost for hydrogen can be cut by 60 - 70% through the utilisation of heat exchanger reactors instead of conventional electrolysis. This result is primarily a result of the high price for electricity compared to the feed stock prices in steam reforming. It is important to verify the performance calculations and the simulation results through experimental

  20. Catalytic heat exchangers for small-scale production of hydrogen - feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Silversand, F. [Catator AB, Lund (Sweden)

    2002-02-01

    A feasibility study concerning heat-exchanger reactors in small-scale production of hydrogen has been performed on the request of Svenskt Gastekniskt Center AB and SWEP International AB. The basic idea is to implement different catalysts into brazed plate-type heat exchangers. This can be achieved by installing catalytic cylinders in the inlet-and outlet ports of the heat exchangers or through treatment of the plates to render them catalytically active. It is also possible to sandwich catalytically active wire meshes between the plates. Experiments concerning steam reforming of methanol and methane have been performed in a micro-reactor to gather kinetic data for modelling purposes. Performance calculations concerning heat exchanger reactors have then been conducted with Catator's generic simulation code for catalytic reactors (CatalystExplorer). The simulations clearly demonstrate the technical performance of these reactors. Indeed, the production rate of hydrogen is expected to be about 10 nm{sup 3}/h per litre of heat exchanger. The corresponding value for a conventional steam-reforming unit is about 1 nm{sup 3}/h or less per litre of reactor volume. Also, the compactness and the high degree of integration together with the possibilities of mass production will give an attractive cost for such units. Depending on the demands concerning the purity of the hydrogen it is possible to add secondary catalytic steps like water-gas shifters, methanation and selective oxidation, into a one-train unit, i.e. to design an all-inclusive design. Such reactors can be used for the supply of hydrogen to fuel cells. The production cost for hydrogen can be cut by 60 - 70% through the utilisation of heat exchanger reactors instead of conventional electrolysis. This result is primarily a result of the high price for electricity compared to the feed stock prices in steam reforming. It is important to verify the performance calculations and the simulation results through

  1. Modernization of Unit 2 at Oskarshamn NPP- Main Objectives, Experience from Design, Separation of Operational and Nuclear Safety Equipment - Lessons Learned

    International Nuclear Information System (INIS)

    Kanaan, Salah K.

    2015-01-01

    This paper aims to give a picture of Oskarshamn Nuclear Power Plant (OKG) experience from design for one of the biggest modernization project in the world and focuses on what was learned that is specific to robustness of electrical power systems, especially through Fukushima Station Blackout (SBO). The planning for unit 2 at OKG was initiated in 1967 and the plant was completed on time and was synchronized to the grid October 2, 1974 and is of type BWR. Unit 2 was originally on 580 MW. In 1982 a thermal power up-rate was performed, from 1700 MWh to 1800 MWh (106% reactor output). A decision was made to perform a modernization and a new power up-rate to 850 MW and there were several reasons for this decision; New safety regulations from Swedish Radiation Safety Authority (SSM), Ageing of important components and the initial focus was on safety and availability - Project Plant Life Extension (Plex) was established and became the largest nuclear power modernization in the world. The modernization will lead to: - New safety concept with 4 divisions instead for existing 2 with 2 new buildings South Electrical Building (SEB) and North Electrical Building (NEB); - Completely new software - based equipments for monitoring, control and I and C; - New Low Pressure Turbine, new generator and main transformer; - New MCR and simulator; - Compliance with modern reactor safety requirements; - Redundancy, Separation, Diversification, Earthquake; - Reinforcement of existing safety functions; - New Electricity - I and C (electric power incl. reinforced emergency power and control systems); - New buildings for Electricity - I and C; - Reinforcement of existing process systems as well as installation of new ones. Based on studies and good experiences on how to separate the operational and the safety equipment, the project led to a completely new safety concept. The safety concept is based on fully understanding the safety system that shall encompass all of the elements required to

  2. Equipment line-up developed for structuring programmed digital systems important to safety

    International Nuclear Information System (INIS)

    Remus, L.; Colling, J.M.; Buisson, J.

    1986-01-01

    The use of the programmed digital techniques in systems important to safety led to developing equipment line-ups which allow to procedure, through using a restricted number of sub-assemblies, a variety of facilities capable of performing diversified functions. Upon remembering the requirements that such equipment are required to meet (quality assurance both at the design and production stages, qualification, testing opportunities, etc.) the equipments produced by MERLIN GERIN are described in this paper. Such equipments include a whole set of printed circuit boards, plug-in units with self-engaging connectors and the related cabinets to accomodate them. The following systems are made up of such equipments: Digital integrated protection system; Rod control and monitoring system; Reactor power distribution monitoring equipment. This equipment line-up has been gradually complemented and is still further expanding both as a result of the component further development or for the purpose of meeting new requirements or applications (new digital neutron instrumentation, local area networks). Experience gained thus far provides us with the capability of working out in a short time programmed systems for further applications in the nuclear power field

  3. Nurse-Patient Communication Interactions in the Intensive Care Unit

    Science.gov (United States)

    Happ, Mary Beth; Garrett, Kathryn; Thomas, Dana DiVirgilio; Tate, Judith; George, Elisabeth; Houze, Martin; Radtke, Jill; Sereika, Susan

    2011-01-01

    Background The inability to speak during critical illness is a source of distress for patients, yet nurse-patient communication in the intensive care unit has not been systematically studied or measured. Objectives To describe communication interactions, methods, and assistive techniques between nurses and nonspeaking critically ill patients in the intensive care unit. Methods Descriptive observational study of the nonintervention/usual care cohort from a larger clinical trial of nurse-patient communication in a medical and a cardiothoracic surgical intensive care unit. Videorecorded interactions between 10 randomly selected nurses (5 per unit) and a convenience sample of 30 critically ill adults (15 per unit) who were awake, responsive, and unable to speak because of respiratory tract intubation were rated for frequency, success, quality, communication methods, and assistive communication techniques. Patients self-rated ease of communication. Results Nurses initiated most (86.2%) of the communication exchanges. Mean rate of completed communication exchange was 2.62 exchanges per minute. The most common positive nurse act was making eye contact with the patient. Although communication exchanges were generally (>70%) successful, more than one-third (37.7%) of communications about pain were unsuccessful. Patients rated 40% of the communication sessions with nurses as somewhat difficult to extremely difficult. Assistive communication strategies were uncommon, with little to no use of assistive communication materials (eg, writing supplies, alphabet or word boards). Conclusions Study results highlight specific areas for improvement in communication between nurses and nonspeaking patients in the intensive care unit, particularly in communication about pain and in the use of assistive communication strategies and communication materials. PMID:21362711

  4. Numerical analysis on interactions between fluid flow and structure deformation in plate-fin heat exchanger by Galerkin method

    Science.gov (United States)

    Liu, Jing-cheng; Wei, Xiu-ting; Zhou, Zhi-yong; Wei, Zhen-wen

    2018-03-01

    The fluid-structure interaction performance of plate-fin heat exchanger (PFHE) with serrated fins in large scale air-separation equipment was investigated in this paper. The stress and deformation of fins were analyzed, besides, the interaction equations were deduced by Galerkin method. The governing equations of fluid flow and heat transfer in PFHE were deduced by finite volume method (FVM). The distribution of strain and stress were calculated in large scale air separation equipment and the coupling situation of serrated fins under laminar situation was analyzed. The results indicated that the interactions between fins and fluid flow in the exchanger have significant impacts on heat transfer enhancement, meanwhile, the strain and stress of fins includes dynamic pressure of the sealing head and flow impact with the increase of flow velocity. The impacts are especially significant at the conjunction of two fins because of the non-alignment fins. It can be concluded that the soldering process and channel width led to structure deformation of fins in the exchanger, and degraded heat transfer efficiency.

  5. Study on Earthquake Response of High Voltage Electrical Equipment Coupling System with Flexible Busbar

    Science.gov (United States)

    Liu, Chuncheng; Qu, Da; Wang, Chongyang; Lv, Chunlei; Li, Guoqiang

    2017-12-01

    With the rapid development of technology and society, all walks of life in China are becoming more and more dependent on power systems. When earthquake occurs, the electrical equipment of substation is prone to damage because of its own structural features, top-heavy, and brittleness of main body. At the same time, due to the complex coupling of the soft electrical connection of substation electrical equipment, the negative impact can not be estimated. In this paper, the finite element model of the coupling system of the single unit of high voltage electrical equipment with the connecting soft bus is established and the seismic response is analysed. The results showed that there is a significant difference between the simple analysis for the seismic response of electrical equipment monomer and the analytical results of electrical equipment systems, and the impact on different electrical equipment is different. It lays a foundation for the future development of seismic performance analysis of extra high voltage electrical equipment.

  6. Zirconium-made equipment for the new La Hague reprocessing plants

    International Nuclear Information System (INIS)

    Decours, J.; Demay, R.; Bernard, C.; Mouroux, J.P.; Simonnet, J.

    1991-01-01

    The use of zirconium was developed to solve some problems of severe corrosion in boiling nitric medium, and to guarantee the service life of the equipment concerned. The paper presents the experience gained since the early 1970s, when the first units made of zirconium were used in French reprocessing plants. For the new La Hague UP3 and UP2 800 plants, it was decided to extend the use of zirconium to make large-scale equipment and, to do so, a major R and D program was implemented, of which the main results are presented

  7. Regulation EM-GT-8. Guidance for quality control of mammography equipment

    International Nuclear Information System (INIS)

    2015-01-01

    Objective: To provide practical guidance of technical procedures for carrying out quality control in mammography equipment. Scope: This guide applies to mammography equipment. A number of methods which require the appointed instrumentation described, some of which can be implemented in radiology services own country given the low complexity of themselves and others that require specific equipment and can be performed by specialized groups external to these units. The guide does not constitute a mandatory, however, the parameters evaluated according to the tests described therein and their tolerances form the basis of regulations that establish the CCEEM about these teams. Overview: The success of mammographic studies depends on obtaining high-quality images combined with a low rate of patient dose. To ensure this objective the establishment of quality assurance programs on all aspects involving these services is necessary. This guide provides a number of quality control procedures aimed at x-ray equipment, which must be performed at least on an annual basis or when some maintenance occurs at x-ray equipment.

  8. Results of pilot project on introducing quality control of mammographic equipment

    International Nuclear Information System (INIS)

    Vasileva, Zh.; Lichev, A.; Dimov, A.; Kostova, E.; Dimov, G.

    2003-01-01

    Objective:The results from a pilot project, realized in the framework of the PHARE Project 'Radiation Protection and Safety in Medical Use of the Ionizing Radiation'. The main goal of the project is the elaboration a quality control program for mammographic equipment and its implementation in 4 radiological units in the country. Another task is to examine the possibility for conducting a mammographic screening using this equipment. Material and methods: The developed quality control program has the following components: test parameters; criteria for intervention; minimal frequency of measurement. Methodologies for measurement of the parameters and assessment of the results in accordance with the European Protocol for physical and technical aspects of the mammographic screening. Standard protocols have been elaborated. Results: The quality program has been tested for three month at different hospitals. Conclusions: Optimization and strict control of the process of film development are needed. The exposure equipment. The quality control program should be implemented on all mammographic equipment in the country. For the performance of mammographic screening a strict selection of the equipment is necessary

  9. Development of processes and equipment for the refabrication of HTGR fuels

    International Nuclear Information System (INIS)

    Sease, J.D.; Lotts, A.L.

    1976-06-01

    Refabrication is in the step in the HTGR thorium fuel cycle that begins with a nitrate solution containing 238 U and culminates in the assembly of this material into fuel elements for use in an HTGR. Refabrication of HTGR fuel is essentially a manufacturing operation and consists of preparation of fuel kernels, application of multiple layers of pyrolytic carbon and SiC, preparation of fuel rods, and assembly of fuel rods in fuel elements. All the equipment for refabrication of 238 U-containing fuel must be designed for completely remote operation and maintenance in hot cell facilities. This paper describes the status of processes and equipment development for the remote refabrication of HTGR fuels. The feasibility of HTGR refabrication processes has been proven by laboratory development. Engineering-scale development is now being performed on a unit basis on the majority of the major equipment items. Engineering-scale equipment described includes full-scale resin loading equipment, a 5-in.-dia (0.13-m) microsphere coating furnace, a fuel rod forming machine, and a cure-in-place furnace

  10. Experimental results for an experimental condensation heat exchanger with a spiral minichanel tube. Comparison to numerical imulations

    Directory of Open Access Journals (Sweden)

    Hrubý J.

    2013-04-01

    Full Text Available The paper describes new results for an experimental heat exchanger equipped with a single corrugated capillary tube, basic information about the measurements and the experimental setup. Some of the results were compared with numerical simulations.

  11. Small Column Ion Exchange Design and Safety Strategy

    International Nuclear Information System (INIS)

    Huff, T.; Rios-Armstrong, M.; Edwards, R.; Herman, D.

    2011-01-01

    Small Column Ion Exchange (SCIX) is a transformational technology originally developed by the Department of Energy (DOE) Environmental Management (EM-30) office and is now being deployed at the Savannah River Site (SRS) to significantly increase overall salt processing capacity and accelerate the Liquid Waste System life-cycle. The process combines strontium and actinide removal using Monosodium Titanate (MST), Rotary Microfiltration, and cesium removal using Crystalline Silicotitanate (CST, specifically UOP IONSIV(reg s ign)IE-911 ion exchanger) to create a low level waste stream to be disposed in grout and a high level waste stream to be vitrified. The process also includes preparation of the streams for disposal, e.g., grinding of the loaded CST material. These waste processing components are technically mature and flowsheet integration studies are being performed including glass formulations studies, application specific thermal modeling, and mixing studies. The deployment program includes design and fabrication of the Rotary Microfilter (RMF) assembly, ion-exchange columns (IXCs), and grinder module, utilizing an integrated system safety design approach. The design concept is to install the process inside an existing waste tank, Tank 41H. The process consists of a feed pump with a set of four RMFs, two IXCs, a media grinder, three Submersible Mixer Pumps (SMPs), and all supporting infrastructure including media receipt and preparation facilities. The design addresses MST mixing to achieve the required strontium and actinide removal and to prevent future retrieval problems. CST achieves very high cesium loadings (up to 1,100 curies per gallon (Ci/gal) bed volume). The design addresses the hazards associated with this material including heat management (in column and in-tank), as detailed in the thermal modeling. The CST must be size reduced for compatibility with downstream processes. The design addresses material transport into and out of the grinder and

  12. RA Reactor operation and maintenance (I-IX), Part III, Task 3.08/04-02 Refurbishment of the electrical equipment; Pogon i odrzavanje reaktora RA (I-IX), III Deo, Zadatak 3.08/04-02 Remont elektro opreme

    Energy Technology Data Exchange (ETDEWEB)

    Zecevic, V; Nikolic, M; Poznanovic, B; Rajic, M [Institute of Nuclear Sciences Boris Kidric, Reaktor RA, Vinca, Beograd (Serbia and Montenegro)

    1963-12-15

    This volume contains detailed action plan for repair of electrical equipment of the RA reactor, the list of electrical equipment parts which were either repaired or exchanged for improvement of their performance. Detailed work describing the repair and maintenance work done of the listed equipment is part of this report. Equipment related to dosimetry and control systems are included as well.

  13. A structural study of nepheline hydrate I, an inorganic ion exchanger

    International Nuclear Information System (INIS)

    Hansen, S.

    1985-01-01

    The crystal structures of nepheline hydrates I, Na 3 Al 3 Si 3 O 12 x 2H 2 O, and three compounds produced by ion exchange with aqueous KCl, RbCl and CsCl at 80 degrees C, have been studied using X-ray diffraction methods. This synthetic silicate has a tetrahedral framework with a two-dimensional pore system consisting of perpendicular 8-ring and 6-ring channels. The long-range ordering of Si and Al into adjacent tetrahedra is well developed. Some aspects of the topology, geometry and bonding of the tetrahedral frame are discussed. Related framework types are derived by unit cell twinning of the idealized cristobalite structure. A limit in the ion exchange is observed when about 1/3 of the Na + ions have been replaced. This behaviour is explained by the restricted volume of two Na sites situated in the 6-ring channel. The readily exchangeable ions and water molecules in the 8-ring channels an arrangement which gradually changes when the size of the alkali metal-ion increases. Most K + -exchanged crystals have a unit cell which is determined by the translational symmetry of the framework, while the original Na form has a two-fold superstructure and the Rb + -exchanged form has a five-fold superstructure. Caesium-ion-exchanged crystals have incommensurate structures. The occurrence of superstructures is related to long-range ordering of the species in the 8-ring channels. (author)

  14. Chromate ion-exchange study for cooling water

    International Nuclear Information System (INIS)

    Sengupta, A.K.

    1985-01-01

    In spite of high chromate selectivity, the ion-exchange process for Cr(IV) recovery from cooling tower blowdown is yet to be commercially popular. Possible degradation of the ion-exchange resin by the oxidative action of Cr(IV) during ion exchange has been considered as the prime obstacle. Resins have been manufactured with fairly acceptable properties to withstand both physical attrition and chemical oxidation. Demonstrated during the course of this research is early, gradual Cr(VI) breakthrough during fixed-bed column runs at acidic pH in the presence of competing sulfate and chloride anions. The advantage of high chromate selectivity is essentially lost due to the early Cr(VI) breakthrough because the column runs are always terminated after a pre-determined level of Cr(VI) has appeared in the treated water. Experimental results provide sufficient evidence that this is not due to poor column kinetics or electrolyte penetration. The chromate ion-exchange mechanism has been investigated in order to explain the foregoing anomalies for the chromate-exchange process. The knowledge of chromate ion-exchange mechanism has been used to overcome the shortcoming of gradual Cr(VI) breakthrough. This study shows that: (a) a continuous counter-current ion-exchange system theoretically offers much higher Cr(VI) removal capacity compared to conventional single-unit fixed-bed system for any pre-determined level of Cr(VI) breakthrough; (b) by modifying the resin composition, the gradual Cr(VI) breakthrough can be greatly eliminated

  15. Radiation tolerance assurance of technical equipment in the LHC radiation monitoring for technical equipment at the LHC

    CERN Document Server

    Wijnands, Thijs; CERN. Geneva. TS Department

    2005-01-01

    In contrast with other accelerators at CERN, a large amount of technical equipment will be located in the LHC tunnel, the underground areas and in the experimental caverns where they will be exposed to radiation. Nearly all this equipment makes, to a certain extent, use of commercial microelectronics which is extremely sensitive to radiation damage, both instantaneous damage and cumulative damage. Examples in the TS Department are the electronics for the position sensors of the low beta quadrupoles, the access system, the cooling and ventilation units, the electronics for the electrical distribution, the oxygen deficiency monitors and fire detection systems. The basic effects of radiation on electronic systems and components are well understood because similar problems with radiation are encountered in the aerospace and aviation industry. Since 1998, an efficient and original Radiation Tolerance Assurance approach for the LHC machine has been established. Its aim is to minimise the effects of radiation damage...

  16. Regenerator heat exchanger – calculation of heat recovery efficiency and pressure loss

    DEFF Research Database (Denmark)

    Pomianowski, Michal Zbigniew; Heiselberg, Per Kvols

    Performance of heat exchangers is determined based on two main parameters: efficiency to exchange / recover heat and pressure loss due to friction between fluid and exchanger surfaces. These two parameters are contradicting each other which mean that the higher is efficiency the higher becomes...... pressure loss. The aim of the optimized design of heat exchanger is to reach the highest or the required heat efficiency and at the same time to keep pressure losses as low as possible keeping total exchanger size within acceptable size. In this report is presented analytical calculation method...... to calculate efficiency and pressure loss in the regenerator heat exchanger with a fixed matrix that will be used in the decentralized ventilation unit combined in the roof window. Moreover, this study presents sensitivity study of regenerator heat exchanger performance, taking into account, such parameters as...

  17. The development of portable equipment to study physical and chemical phases in natural waters

    International Nuclear Information System (INIS)

    Breward, N.; Peachey, D.

    1988-08-01

    A direct and relatively non-invasive method of measuring the speciation of dissolved metals in groundwaters has been developed. The equipment relies on a series of columns containing DAEA cellulose, cation exchange resin and anion exchange resin to extract sequentially and respectively colloids, cationic and anionic species. Organic colloids are eluted from the DAEA cellulose with dilute caustic soda while the inorganic colloids (Fe/Al oxyhydroxide phase) are stripped with dilute mineral acid. A further advantage of this scheme is the ability to concentrate the phases by at least a factor of ten. Applications to the groundwaters of the natural analogue sites currently under study by BGS will offer a means of validating thermodynamic databases used in modelling speciation of radionuclides such as uranium and thorium. (author)

  18. Report for fiscal 1998 on the international joint research project of medical welfare equipment; Iryo fukushi kiki kokusai kyodo kenkyu jigyo 1998 nendo chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    In connection with the international joint research project of medical welfare, a report was made on the results of the investigation conducted in 1998 concerning the technology of overseas medical welfare equipment. In the investigation of china, observation was made on the actual state of the representative medial institutions, with opinions exchanged. Obsolete equipment and old technology are the present state in China, which is strongly desirous of exchanging information with Japan. In Taiwan, being full of venture spirit, an ultrasonic thermal treatment apparatus and an ultrasonic echo device have been produced for example. In Europe, an observation tour was conducted on a German manipulator and process robot while an investigative visit and exchange of opinions were made on the living environment and facilities in Italian training center for physically handicapped persons. Japan's self-supporting and assisting system for excretion attracted many questions and comments. In the investigation in the U.S., views were exchanged concerning '{sup 13}C-MRS device for non-invasion brain metabolic measurement' in research institutions such as universities. A machine developed in Japan received a high evaluation in that {sup 13}C spectrum was obtained from a substantial depth. (NEDO)

  19. Semiconductor Manufacturing equipment introduction

    International Nuclear Information System (INIS)

    Im, Jong Sun

    2001-02-01

    This book deals with semiconductor manufacturing equipment. It is comprised of nine chapters, which are manufacturing process of semiconductor device, history of semiconductor manufacturing equipment, kinds and role of semiconductor manufacturing equipment, construction and method of semiconductor manufacturing equipment, introduction of various semiconductor manufacturing equipment, spots of semiconductor manufacturing, technical elements of semiconductor manufacturing equipment, road map of technology of semiconductor manufacturing equipment and semiconductor manufacturing equipment in the 21st century.

  20. Mixed filling for the successive isotopic exchange in the phase sequence water - water vapors - hydrogen

    International Nuclear Information System (INIS)

    Stefanescu, D.; Peculea, M.; Hirean, I.; Croitoru, C.

    1995-01-01

    The paper deals with the process of the isotopic exchange implied in heavy water production. Details concerning the structural arrangement of the process contact elements inside the exchange columns are presented. A hydrophilic filling, based on phosphorous bronze, and the platinum catalyst structure , resulted from this work, are to be implemented in the column equipment of the heavy water distillation pilot operating in connection with the CANDU type reactors. The performances of the mixed catalyst components were derived from experimental data by means of the three fluids model equations

  1. Communication of 2 June 2009 received from the Permanent Mission of the United Kingdom regarding the Export of Nuclear Material and of Certain Categories of Equipment and Other Material

    International Nuclear Information System (INIS)

    2009-01-01

    The Director General has received a note ver bale from the Permanent Mission of the United Kingdom, dated 2 June 2009, in which it requests that the Agency circulate to all Member States a letter of 28 May 2009 from the Chairman of the Zangger Committee, Mr. Pavel Klucky, to the Director General, on behalf of the Governments of Argentina, Australia, Austria, Belgium, Bulgaria, Canada, China, Croatia, Denmark, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Japan, Kazakhstan, the Republic of Korea, Luxemburg, the Netherlands, Norway, Poland, Portugal, Romania, the Russian Federation, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Turkey, Ukraine, the United Kingdom and the United States of America, concerning a number of corrections to the communication regarding the export of nuclear material and of certain categories of equipment and other material published in INFCIRC/209/Rev.2 [fr

  2. Communication of 2 June 2009 received from the Permanent Mission of the United Kingdom regarding the Export of Nuclear Material and of Certain Categories of Equipment and Other Material

    International Nuclear Information System (INIS)

    2009-01-01

    The Director General has received a note ver bale from the Permanent Mission of the United Kingdom, dated 2 June 2009, in which it requests that the Agency circulate to all Member States a letter of 28 May 2009 from the Chairman of the Zangger Committee, Mr. Pavel Klucky, to the Director General, on behalf of the Governments of Argentina, Australia, Austria, Belgium, Bulgaria, Canada, China, Croatia, Denmark, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Japan, Kazakhstan, the Republic of Korea, Luxemburg, the Netherlands, Norway, Poland, Portugal, Romania, the Russian Federation, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Turkey, Ukraine, the United Kingdom and the United States of America, concerning a number of corrections to the communication regarding the export of nuclear material and of certain categories of equipment and other material published in INFCIRC/209/Rev.2 [ru

  3. Communication of 2 June 2009 received from the Permanent Mission of the United Kingdom regarding the Export of Nuclear Material and of Certain Categories of Equipment and Other Material

    International Nuclear Information System (INIS)

    2009-01-01

    The Director General has received a note ver bale from the Permanent Mission of the United Kingdom, dated 2 June 2009, in which it requests that the Agency circulate to all Member States a letter of 28 May 2009 from the Chairman of the Zangger Committee, Mr. Pavel Klucky, to the Director General, on behalf of the Governments of Argentina, Australia, Austria, Belgium, Bulgaria, Canada, China, Croatia, Denmark, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Japan, Kazakhstan, the Republic of Korea, Luxemburg, the Netherlands, Norway, Poland, Portugal, Romania, the Russian Federation, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Turkey, Ukraine, the United Kingdom and the United States of America, concerning a number of corrections to the communication regarding the export of nuclear material and of certain categories of equipment and other material published in INFCIRC/209/Rev.2 [es

  4. Plastic heat exchangers: a state-of-the-art review

    Energy Technology Data Exchange (ETDEWEB)

    Miller, D; Holtz, R E; Koopman, R N; Marciniak, T J; MacFarlane, D R

    1979-07-01

    Significant increases in energy utilization efficiency can be achieved through the recovery of low-temperature rejected heat. This energy conserving possibility provides incentive for the development of heat exchangers which could be employed in applications where conventional units cannot be used. Some unique anticorrosion and nonstick characteristics of plastics make this material very attractive for heat recovery where condensation, especially sulfuric acid, and fouling occur. Some of the unique characteristics of plastics led to the commercial success of DuPont's heat exchangers utilizing polytetrafluoroethylene (trade name Teflon) tubes. Attributes which were exploited in this application were the extreme chemical inertness of the material and its flexibility, which enabled utilization in odd-shaped spaces. The wide variety of polymeric materials available ensures chemical inertness for almost any application. Lower cost, compoundability with fillers to improve thermal/mechanical properties, and versatile fabrication methods are incentives for many uses. Also, since many plastics resist corrosion, they can be employed in lower temperature applications (< 436 K), where condensation can occur and metal units have been unable to function. It is clear that if application and design can be merged to produce a cost-effective alternate to present methods of handling low-temperature rejected heat, then there is significant incentive for plastic heat exchangers, to replace traditional metallic heat exchangers or to be used in services where metals are totally unsuited.

  5. Fuel Handling Equipment Maintenance for Critical Path Time Savings

    Energy Technology Data Exchange (ETDEWEB)

    Saville, M.; Williams, A.

    2015-07-01

    By sharing lessons learned and operating experience gained by AREVA Stearns RogerTM Services from more than 45 years of servicing, maintaining, and upgrading Fuel Handling Equipment (FHE) and as the original equipment manufacturer to 56% of domestic U.S. FHE (PWR and BWR) as well as 19 units overseas, this paper presents trends and market forces that have led to the neglect of FHE, the risks of not adequately maintaining FHE, and the financial benefits of proactively maintaining FHE. The benefit to audiences is to come to a better understanding of how critical path delays can be avoided and thus reduce nuclear power plant operating costs. Note that statistics and monetary values given herein are based on recent typical experiences of AREVA Stearns RogerTM Services. Examples discussed are based on actual lessons learned. For the purposes of this paper, upgrades are considered a part of equipment maintenance unless specifically discussed separately. (Author)

  6. Test of Weak Form Efficiency: An Empirical Study of the Malaysian Foreign Exchange Market

    OpenAIRE

    Lim, Pei Mun

    2011-01-01

    This paper empirically tests the Efficient Market Hypothesis (EMH) in the weak sense for the Malaysian foreign exchange market. The hypothesis is tested using two ways. First is by testing the random walk hypothesis based on individual unit root test and second is by testing the profitability of simple technical trading rules. The study covers the high frequency daily data from January 1997 to December 2010 and the spot exchange rates are quoted as Malaysian Ringgit per unit of US Dollar. Due...

  7. Second unit scheduling concerns on a dual-unit nuclear project

    International Nuclear Information System (INIS)

    Block, H.R.; Mazzini, R.A.

    1978-01-01

    This paper explores the planning and scheduling problems of Unit 2 of the Susquehanna steam electric station. The causes of these problems and methods to avoid or mitigate their consequences are discussed. The Susquehanna steam electric station has two boiling water reactors rated at 1,100 MW each. Topics considered include cost factors, structures, equipment, engineering and home office, construction services, completion data phasing, work sequencing, structural dependences, and segregation. Substatial cost and schedule benefits can result if two nuclear units are designed and constructed as one integral station, and if maximum sharing of facilities and services between the units occurs. It is concluded that the cost benefits of highly integrated dual unit construction outweigh the schedule and logistical problems caused by that approach

  8. Experimental study of particulate fouling onto heat exchanger elements

    International Nuclear Information System (INIS)

    Chandrasa

    1994-01-01

    An experimental study of particulate fouling onto tubular heat exchanger surfaces was carried out using sodium sulfate particles. An experimental apparatus equipped with an aerosol generator has been used to examine the deposition of small particles under controlled conditions. Two sets of experiments were performed. Firstly, the deposition against time of solid particles onto single heat exchanger tube in cross-flow was studied. The effects of a number variables such as particle size, gas velocity and temperature on the deposition was analysed. Secondly, the deposition for the aerosol particles as they passed through a bank of finned tubes was examined. The deposition patterns on various tubes depended on local conditions (velocity and temperature) within the bank. It was found that the fouling resistance increases as aerosol flow rate decreases. The smaller particles showed higher fouling resistance. (author) [fr

  9. Pass-through of exchange rates and tariffs in Greek-US tobacco trade

    OpenAIRE

    Rezitis, Anthony N.; Brown, A. Blake

    1999-01-01

    The paper examines the extent to which exchange rate and unit tariff changes are passed-through in US import prices of unmanufactured Greek oriental tobacco. The results indicate partial pass-through of exchange rates and tariffs. Exchange rate pass-through is about 0.272 and tariff pass-through about 0.185. One possible reason for the partial pass-through is oligopoly in tobacco exporting. Oligopoly would imply that depreciation of the drachma relative to the US dollar benefits tobacco expor...

  10. Composition of plastics from waste electrical and electronic equipment (WEEE) by direct sampling.

    Science.gov (United States)

    Martinho, Graça; Pires, Ana; Saraiva, Luanha; Ribeiro, Rita

    2012-06-01

    This paper describes a direct analysis study carried out in a recycling unit for waste electrical and electronic equipment (WEEE) in Portugal to characterize the plastic constituents of WEEE. Approximately 3400 items, including cooling appliances, small WEEE, printers, copying equipment, central processing units, cathode ray tube (CRT) monitors and CRT televisions were characterized, with the analysis finding around 6000 kg of plastics with several polymer types. The most common polymers are polystyrene, acrylonitrile-butadiene-styrene, polycarbonate blends, high-impact polystyrene and polypropylene. Additives to darken color are common contaminants in these plastics when used in CRT televisions and small WEEE. These additives can make plastic identification difficult, along with missing polymer identification and flame retardant identification marks. These drawbacks contribute to the inefficiency of manual dismantling of WEEE, which is the typical recycling process in Portugal. The information found here can be used to set a baseline for the plastics recycling industry and provide information for ecodesign in electrical and electronic equipment production. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Modification and Validation of an Automotive Data Processing Unit, Compessed Video System, and Communications Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Carter, R.J.

    1997-04-01

    The primary purpose of the "modification and validation of an automotive data processing unit (DPU), compressed video system, and communications equipment" cooperative research and development agreement (CRADA) was to modify and validate both hardware and software, developed by Scientific Atlanta, Incorporated (S-A) for defense applications (e.g., rotary-wing airplanes), for the commercial sector surface transportation domain (i.e., automobiles and trucks). S-A also furnished a state-of-the-art compressed video digital storage and retrieval system (CVDSRS), and off-the-shelf data storage and transmission equipment to support the data acquisition system for crash avoidance research (DASCAR) project conducted by Oak Ridge National Laboratory (ORNL). In turn, S-A received access to hardware and technology related to DASCAR. DASCAR was subsequently removed completely and installation was repeated a number of times to gain an accurate idea of complete installation, operation, and removal of DASCAR. Upon satisfactory completion of the DASCAR construction and preliminary shakedown, ORNL provided NHTSA with an operational demonstration of DASCAR at their East Liberty, OH test facility. The demonstration included an on-the-road demonstration of the entire data acquisition system using NHTSA'S test track. In addition, the demonstration also consisted of a briefing, containing the following: ORNL generated a plan for validating the prototype data acquisition system with regard to: removal of DASCAR from an existing vehicle, and installation and calibration in other vehicles; reliability of the sensors and systems; data collection and transmission process (data integrity); impact on the drivability of the vehicle and obtrusiveness of the system to the driver; data analysis procedures; conspicuousness of the vehicle to other drivers; and DASCAR installation and removal training and documentation. In order to identify any operational problems not captured by the systems

  12. A study on the formation of fouling in a heat exchanging system for Han-river water as cooling water

    International Nuclear Information System (INIS)

    Sung, Sun Kyung; Suh, Sang Ho; Rho, Hyung Woon; Cho, Young Il

    2003-01-01

    Scale is formed when hard water is heated or cooled in heat transfer equipments such as heat exchangers, condensers, evaporators, cooling towers, boilers, and pipe walls. When scale deposits in a heat exchanger surface, it is traditionally called fouling. The objective of the present study is to investigate the formation of fouling in a heat exchanging system. A lab-scale heat exchanging system is built-up to observe and measure the formation of fouling experimentally. Water analyses are conducted to obtain the properties of Han river water. In the present study a microscopic observation is conducted to visualize the process of scale formation. Hardness of Han-river water is higher than that of tap water in Seoul

  13. Knowledge Exchange between Poland and Vietnam in Mining and Geology - the Status Quo and Future Development

    Science.gov (United States)

    Nguyen, Nga; Pham, Nguyet

    2018-03-01

    From the beginning of the 21st century, knowledge exchange between Poland and Vietnam in mining and geology has been focusing in technology, education and training. Since years, Polish academic and commercial partners have been developing a close collaboration with Vietnam National Coal - Mineral Industries Holding Corporation Limited. Major outcomes of the collaboration are installations and operation of mining equipments and machines in Vietnamese mining companies, and excellent training programs for graduate and post graduate students and mining staff for both countries, etc. From aspects of knowledge management in globalization, the article highlights the outstanding outcomes of knowledge exchanges between the two countries, outlines cultural and economic challenges for the exchange and proposes some improvement in the future.

  14. Research on U.S. nuclear power plant major equipment aging

    International Nuclear Information System (INIS)

    Nakos, J.T.; Rosinski, S.T.

    1994-01-01

    The U.S. Department of Energy (DOE) and the Electric Power Research Institute (EPRI), in cooperation with nuclear power plant utilities and the Nuclear Energy Institute, have prepared equipment aging evaluations of nuclear power plant equipment for life extension considerations. Specifically, these evaluations focused on equipment considered important for plant license renewal (U.S. Code of Federal Regulations 10CFR54). open-quotes Industry Reportsclose quotes (IRs), jointly funded by DOE and EPRI, evaluated the aging of major systems, structures, and components (e.g., reactor pressure vessels, Class I structures, PWR and BWR containments, etc.) and contain a mixture of technical and licensing information. open-quotes Aging Management Guidelinesclose quotes (AMGs), funded by DOE, evaluate aging for commodity types of equipment (e.g., pumps, electrical switchgear, heat exchangers, etc.) and concentrate on technical issues only. AMGs are intended for systems engineers and plant maintenance staff. A significant number of technical issues were resolved during IR interactions with the U.S. Nuclear Regulatory Commission (NRC). However, certain technical issues have not been resolved and are considered open-quotes openclose quotes. Examples include certain issues related to fatigue, neutron irradiation embrittlement, intergranular stress corrosion cracking (IGSCC) and electrical cable equipment qualification. Direct NRC interaction did not take place during preparation of individual AMGs due to their purely technical nature. The eventual use of AMGs in a future license renewal application will likely require NRC interaction at that time. With a few noted exceptions, the AMG process indicated that current aging management practices of U.S. utilities were effective in preventing age-related degradation. This paper briefly describes the IR and AMG processes and summarizes the unresolved technical issues identified through preparation of the documents

  15. Electrical equipment qualification

    International Nuclear Information System (INIS)

    Farmer, W.S.

    1983-01-01

    Electrical equipment qualification research programs being carried out by CEA, JAERI, and Sandia Laboratories are discussed. Objectives of the program are: (1) assessment of accident simulation methods for electrical equipment qualification testing; lower coarse (2) evaluation of equipment aging and accelerated aging methods; (3) determine radiation dose spectrum to electrical equipment and assess simulation methods for qualification; (4) identify inadequacies in electrical equipment qualification procedures and standards and potential failure modes; and (5) provide data for verifying and improving standards, rules and regulatory guides

  16. Space Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1998-01-01

    The performance evaluation of space heating equipment for a geothermal application is generally considered from either of two perspectives: (a) selecting equipment for installation in new construction, or (b) evaluating the performance and retrofit requirements of an existing system. With regard to new construction, the procedure is relatively straightforward. Once the heating requirements are determined, the process need only involve the selection of appropriately sized hot water heating equipment based on the available water temperature. It is important to remember that space heating equipment for geothermal applications is the same equipment used in non-geothermal applications. What makes geothermal applications unique is that the equipment is generally applied at temperatures and flow rates that depart significantly from traditional heating system design. This chapter presents general considerations for the performance of heating equipment at non-standard temperature and flow conditions, retrofit of existing systems, and aspects of domestic hot water heating.

  17. Beyond the glitz of new equipment

    International Nuclear Information System (INIS)

    Stolberg, H.O.; Nahmias, C.

    2001-01-01

    Canadian radiologists were informed by the press on Mar. 17, 2001, about an important initiative of their national organization. The CAR had commissioned a Montreal law firm to provide a legal opinion about the use of 'obsolete equipment'. The lawyer of the law firm opined that 'it is imperative that the patient be advised and understand the risks and uncertainties associated with the reliability of such an examination'. The 5-page legal opinion (available at www.car.ca) also recommended that radiologists inform patients that they should consider shopping around for a hospital or clinic with newer machines, even if it means travelling out of the country. When summarizing the legal advice for the media, the Chief Executive Officer of the CAR said radiologists should advise patients if better equipment is available in other facilities, including 'private facilities', or in other jurisdictions, such as the United States. These developments should be of great concern to Canadian radiologists who are well aware of the problems associated with aging equipment and the lack of and limited access to newer imaging modalities. The legal initiative of the CAR, however, makes it imperative for individual radiologists to provide comments and for the CAR executive to answer a number of questions and address a number of priorities, including the following. (author)

  18. Seismic and environmental qualification of class IE equipment manufactured in Spain

    International Nuclear Information System (INIS)

    Gerini, P.; Lumbreras, A.; Naredo, F.

    1978-01-01

    Nuclear power plant instrumentation and control design is affected by several factors such as various plant operating conditions, transient response capability, safety requirements and changes in IEEE standards. Recent upgraded IEEE standards that call for Qualification of all Safety related I anc C equipment, namely IEEE 323 (Qualifying Class IE Electric Equipment for nuclear power generating stations) and its daughter Standard IEEE 344 (Recommended Practices for Seismic Qualification of Class IE Equipment for nuclear power generating stations) have been endorsed by the United States Nuclear Regulatory Commission through the issuance of corresponding Regulatory Guides. The author describes the Qualification requirements applicable to the Class IE I and C Components made in Spain for the different vintages of plants, and the programs implemented or plans established by Westinghouse to fulfill those requirements. (author)

  19. Harnessing Private-Sector Innovation to Improve Health Insurance Exchanges.

    Science.gov (United States)

    Gresenz, Carole Roan; Hoch, Emily; Eibner, Christine; Rudin, Robert S; Mattke, Soeren

    2016-05-09

    Overhauling the individual health insurance market-including through the creation of health insurance exchanges-was a key component of the Patient Protection and Affordable Care Act's multidimensional approach to addressing the long-standing problem of the uninsured in the United States. Despite succeeding in enrolling millions of Americans, the exchanges still face several challenges, including poor consumer experience, high operational and development costs, and incomplete market penetration. In light of these challenges, analysts considered a different model for the exchanges-privately facilitated exchanges-which could address these challenges and deepen the Affordable Care Act's impact. In this model, the government retains control over sovereign exchange functions but allows the private sector to assume responsibility for more-peripheral exchange functions, such as developing and sustaining exchange websites. Although private-sector entities have already undertaken exchange-related functions on a limited basis, privately facilitated exchanges could conceivably relieve the government of its responsibility for front-end website operations and consumer decision-support functions entirely. A shift to privately facilitated exchanges could improve the consumer experience, increase enrollment, and lower costs for state and federal governments. A move to such a model requires, nonetheless, managing its risks, such as reduced consumer protection, increased consumer confusion, and the possible lack of a viable revenue base for privately facilitated exchanges, especially in less populous states. On net, the benefits are large enough and the risks sufficiently manageable to seriously consider such a shift. This paper provides background information and more detail on the analysts' assessment.

  20. Market Risk in Demutualised Self-Listed Stock Exchanges: An International Analysis of Selected Time-Varying Betas

    OpenAIRE

    Andrew Worthington; Helen Higgs

    2005-01-01

    This paper examines market risk in four demutualised and self-listed stock exchanges: the Australian Stock Exchange, the Deutsche Börse, the London Stock Exchange and the Singapore Stock Exchange. Daily company and MSCI index returns provide the respective asset and market portfolio data. A bivariate MA-GARCH model is used to estimate time-varying betas for each exchange from listing until 7 June 2005. While the results indicate significant beta volatility, unit root tests show the betas to b...

  1. Quantification of iopamidol multi-site chemical exchange properties for ratiometric chemical exchange saturation transfer (CEST) imaging of pH

    International Nuclear Information System (INIS)

    Sun, Phillip Zhe; Longo, Dario Livio; Hu, Wei; Xiao, Gang; Wu, Renhua

    2014-01-01

    pH-sensitive chemical exchange saturation transfer (CEST) MRI holds great promise for in vivo applications. However, the CEST effect depends on not only exchange rate and hence pH, but also on the contrast agent concentration, which must be determined independently for pH quantification. Ratiometric CEST MRI normalizes the concentration effect by comparing CEST measurements of multiple labile protons to simplify pH determination. Iopamidol, a commonly used x-ray contrast agent, has been explored as a ratiometric CEST agent for imaging pH. However, iopamidol CEST properties have not been solved, determination of which is important for optimization and quantification of iopamidol pH imaging. Our study numerically solved iopamidol multi-site pH-dependent chemical exchange properties. We found that iopamidol CEST MRI is suitable for measuring pH between 6 and 7.5 despite that T 1 and T 2 measurements varied substantially with pH and concentration. The pH MRI precision decreased with pH and concentration. The standard deviation of pH determined from MRI was 0.2 and 0.4 pH unit for 40 and 20 mM iopamidol solution of pH 6, and it improved to be less than 0.1 unit for pH above 7. Moreover, we determined base-catalyzed chemical exchange for 2-hydrooxypropanamido (k sw = 1.2*10 pH−4.1 ) and amide (k sw = 1.2*10 pH−4.6 ) protons that are statistically different from each other (P < 0.01, ANCOVA), understanding of which should help guide in vivo translation of iopamidol pH imaging. (paper)

  2. Estimation and optimization of heat transfer and overall presure drop for a shell and tube heat exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Bala Bhaskara [Dept. of Mechanical Engineering, SISTAM College, JNTU, Kakinada (India); Raju, V. Ramachandra [Dept. of Mechanical Engineering, JNTU, Kakinada (India); Deepak, B. B V. L. [Dept. of Industrial Design, National Institute of Technology, Rourkela (India)

    2017-01-15

    Most thermal/chemical industries are equipped with heat exchangers to enhance thermal efficiency. The performance of heat exchangers highly depends on design modifications in the tube side, such as the cross-sectional area, orientation, and baffle cut of the tube. However, these parameters do not exhibit a specific relation to determining the optimum design condition for shell and tube heat exchangers with a maximum heat transfer rate and reduced pressure drops. Accordingly, experimental and numerical simulations are performed for a heat exchanger with varying tube geometries. The heat exchanger considered in this investigation is a single-shell, multiple-pass device. A Generalized regression neural network (GRNN) is applied to generate a relation among the input and output process parameters for the experimental data sets. Then, an Artificial immune system (AIS) is used with GRNN to obtain optimized input parameters. Lastly, results are presented for the developed hybrid GRNN-AIS approach.

  3. The Hatch-Smolensk exchange

    International Nuclear Information System (INIS)

    Sproles, A.

    1993-01-01

    During summer 1992, the World Association of Nuclear Operators (WANO) sponsored an exchange visit between Georgia Power Company's Edwin I. Hatch nuclear plant, a two-unit boiling water reactor site, and the Smolensk atomic energy station, a three-unit RBMK (graphite-moderated and light-water-cooled) plant located 350 km west of Moscow, in Desnogorsk, Russia. The Plant Hatch team included Glenn Goode, manager of engineering support; Curtis Coggin, manager of training and emergency preparedness; Wayne Kirkley, manager of health physics and chemistry; John Lewis, manager of operations; Ray Baker, coordinator of nuclear fuels and contracts; and Bruce McLeod, manager of nuclear maintenance support. Also traveling with the team was Jerald Towgood, of WANO's Atlanta Centre. The Hatch team visited the Smolensk plant during the week of July 27, 1992

  4. A challenging task: cleaning and repairing at nuclear power plant ATUCHA I (CAN-I) the primary's moderators cooling circuits heat exchangers

    International Nuclear Information System (INIS)

    Amaya, D.; Alaniz, A.; Bernasconi, R.

    2005-01-01

    A set of automatic and semiautomatic machines and tools were designed for the accomplishment of remotely controlled works in high radiation fields on the ATUCHA-I moderator heat exchangers. The object of this equipment is to carry out works related to the cleaning, inspection and eventual blocking of the heat exchanger's tubes. Due to the special characteristics of the area, such as difficult access, not much space and high dose rates, the remote operation of highly trained and specialized personnel with specially designed tools, is mandatory. The Principal operations consist of: 1. Equipment manually taken to the area by specialized personnel. 2. Remote cutting the bolting and cutting and re-weld seals with custom designed equipment. 3. Remote cutting and re-weld piping connections with equipment on customized tracks, special supports, drives and commands. 4. Remote cleaning, leak testing, machining and plugging of the tube sheets with a custom-made master-slave/Cartesian robotic manipulators. 5. Monitoring with video cameras and lighting systems incorporated into the equipment. 6. Ands others task as piping stabilization, supporting and moving flanges, re-alignment of seals and pipes, etc. This paper describes the entire development of this project, starting from the initial work plan to the completion of the first on-site work carried out at the facility. Including descriptions, drawings and pictures of the custom designed equipment, description of the performed works and comparisons between the actual doses and estimated manual operation doses. (authors)

  5. Heat exchanger design considerations for high temperature gas-cooled reactor (HTGR) plants

    International Nuclear Information System (INIS)

    McDonald, C.F.; Vrable, D.L.; Van Hagan, T.H.; King, J.H.; Spring, A.H.

    1980-02-01

    Various aspects of the high-temperature heat exchanger conceptual designs for the gas turbine (HTGR-GT) and process heat (HTGR-PH) plants are discussed. Topics include technology background, heat exchanger types, surface geometry, thermal sizing, performance, material selection, mechanical design, fabrication, and the systems-related impact of installation and integration of the units in the prestressed concrete reactor vessel. The impact of future technology developments, such as the utilization of nonmetallic materials and advanced heat exchanger surface geometries and methods of construction, is also discussed

  6. An analysis of the efficiency of the foreign exchange market in Kenya

    OpenAIRE

    Sifunjo E. Kisaka; Wainaina Gituro; Pokhariyal Ganesh; Ngugi W. Rose

    2008-01-01

    This study examined the Efficiency Market hypothesis in its weak form using run tests, unit root tests and the Ljung-Box Q-statistics. The motivation was to determine whether foreign exchange rate returns follow a random walk. The data covered the period starting January 1994 to June 2007 for the daily closing spot price of the Kenya shillings per US dollar exchange rate. The main finding of this study is that the foreign exchange rate market is not efficient. The results showed that most of ...

  7. On the evolution of U.S. foreign-exchange-market intervention: thesis, theory, and institutions

    OpenAIRE

    Michael D. Bordo; Owen F. Humpage; Anna J. Schwartz

    2011-01-01

    Attitudes about foreign-exchange-market intervention in the United States evolved in tandem with views about monetary policy as policy makers grappled with the perennial problem of having more economic objectives than independent instruments with which to achieve them. This paper—the introductory chapter to our history of U.S. foreign exchange market intervention—explains this thesis and summarizes our conclusion: The Federal Reserve abandoned frequent foreign-exchange-market intervention bec...

  8. Development of automatic nuclear plate analyzing system equipped with TV measuring unit and its application to analysis of elementary particle reaction, 1

    International Nuclear Information System (INIS)

    Ushida, Noriyuki

    1987-01-01

    Various improvements are made on an analysis system which was previously reported. Twenty five emulsion plates, each with a decreased size of 3 cm x 3 cm, are mounted on a single acrylic resin sheet to reduce the required measurement time. An interface called New DOMS (digitized on-line microscope) is designed to reduce the analysis time and to improve the reliability of the analysis. The newly developed analysis system consists of five blocks: a stage block (with measuring range of 170 mm along the x and y axes and 2 mm along the z axis and an accuracy of 1 μm for each axis), DG-M10 host computer (with external storages for 15M byte hard disk and 368k byte minifloppy disk), DOMS interface (for control of the stage, operation of the graphic image and control of the CCD TV measuring unit), CCD TV measuring unit (equipped with a CCD TV camera to display the observed emulsion on a TV monitor for measuring the grain position), and measurement terminal (consisting of a picture monitor, video terminal module and keyboards). This report also shows a DOMS system function block diagram (crate controller and I/O, phase converter, motor controller, sub CPU for dysplay, graphic memory, ROM writer, power supply), describes the CCD TV measuring unit hardware (CCD TV camera, sync. separator, window generator, darkest point detector, mixer, focus counter), and outlines the connections among the components. (Nogami, K.)

  9. Device for removing alkali metal residues from heat exchanger

    International Nuclear Information System (INIS)

    Matal, O.

    1987-01-01

    The main parts of the facility consists of a condensing vessel and a vacuum pump unit interconnected via a vacuum pipe. The heat exchanger is heated to a temperature at which the alkali metal residues evaporate. Metal vapors are collected in the condensing vessel where they condense. The removal of the alkali metal residues from the heat exchanger pipes allows thorough inspection of the pipe inside during scheduled nuclear power plant shutdowns. The facility can be used especially with reverse steam generators. (E.S.). 1 fig

  10. A multilevel investigation on nursing turnover intention: the cross-level role of leader-member exchange.

    Science.gov (United States)

    Portoghese, Igor; Galletta, Maura; Battistelli, Adalgisa; Leiter, Michael P

    2015-09-01

    To analyse nursing turnover intention from the unit by using multilevel approach, examining at the individual level, the relationships between job characteristics, job satisfaction and turnover intention, and at the group level the role of leader-member exchange. Research on nursing turnover has given little attention to the effects of multilevel factors. Aggregated data of 935 nurses nested within 74 teams of four Italian hospitals were collected in 2009 via a self-administered questionnaire. Hierarchical linear modelling showed that job satisfaction mediated the relationship between job characteristics and intention to leave at the individual level. At the unit level, leader-member exchange was directly linked to intention to leave. Furthermore, cross-level interaction revealed that leader-member exchange moderated the relationship between job characteristics and job satisfaction. This study supported previous research in single-level turnover studies concerning the key role of job satisfaction, providing evidence that job characteristics are important in creating motivating and satisfying jobs. At the unit-level, leader-member exchange offers an approach to understand the role of unit-specific conditions created by leaders on nurses' workplace wellbeing. This study showed that it is important for nursing managers to recognise the relevance of implementing management practices that foster healthy workplaces centred on high-quality nurse-supervisor relationships. © 2014 John Wiley & Sons Ltd.

  11. Establishment for Nuclear Equipment: Overview

    International Nuclear Information System (INIS)

    Pracz, J.

    2001-01-01

    Full text: The activity of ZdAJ in 2000 was focused on realisation of the Government-Ordered Project - 6/15 MeV Accelerator. The realisation was accomplished in two stages: - stage I should result in deriving principal operational parameters of the accelerator - stage 2 will result in full implementation of the control system providing optimum control of the equipment and automatic maintaining of its parameters. Within the frames of the first stage, a klystron modulator panel was finished and the design documentation of the mechanical supporting structure, the arm, accelerating structure, collimator and control panel were advanced. Manufacturing of the above sub-units in the workshop has started. In the frames of the Specific Project of the State Committee for Scientific Research, the improvement of Neptun lOPC accelerator was undertaken. The read-out of the monitor dose with atmospheric pressure and ambient temperature compensation has been introduced. New filters for equalising the photon and electron beam and new wedge filters have been designed. Changes in programming have been introduced, which improve the patient's safety by eliminating possible personnel errors and increase the accuracy of radiation fields read-out. In 2000 ZdAJ progressed in development of the Quality System conforming EN-ISO 9001 Standard by including the provisions of EN 46001 Standard. The Standard EN 46001: ''Quality Systems - Medical Equipment''. Detailed requirements related to application of EN ISO 9001 is an European Quality Standard extending the provisions of EN ISO 9001 Standard over the manufacturers of medical equipment. (author)

  12. Real Effective Exchange Rate Dynamics in Malawi and South Africa

    OpenAIRE

    Kisu Simwaka

    2004-01-01

    This study investigates the main determinants of real effective exchange rate in Malawi and South Africa. In our empirical analysis, we conducted unit root and cointegration test in order to determine the time series properties of the data and establish whether there is a long run relationship between real effective exchange rate and explanatory variables. Having ascertained that almost all variiables are integrated of order one and cointegrated, an error correction model is formulated and es...

  13. Estimating the Effects of Exchange Rate Volatility on Export Volumes

    OpenAIRE

    Wang, Kai-Li; Barrett, Christopher B.

    2007-01-01

    This paper takes a new empirical look at the long-standing question of the effect of exchange rate volatility on international trade flows by studying the case of Taiwan's exports to the United States from 1989-1998. In particular, we employ sectoral-level, monthly data and an innovative multivariate GARCH-M estimator with corrections for leptokurtic errors. This estimator allows for the possibility that traders' forward-looking contracting behavior might condition the way in which exchange r...

  14. Experimental and Numerical Study of the Radiant Induction-Unit and the Induction Radiant Air-Conditioning System

    Directory of Open Access Journals (Sweden)

    Qiang Si

    2016-12-01

    Full Text Available In this paper we proposed the novel air-conditioning system which combined induction ventilation and radiant air-conditioning. The indoor terminal device is the radiant induction-unit (RIDU. The RIDU is the induction unit combined with the pore radiant panel on which the copper pipes with rigid aluminum diffusion fins are installed. The two-stage evaporator chiller with the non-azeotropic mixture refrigerant is utilized in the system to reduce the initial investment in equipment. With the performance test and the steady state heat transfer model based on the theory of radiative heat transfer, the relationship between the induction ratio of the RIDU and the characteristic of the air supply was studied. Based on this, it is verified that the RIDU has a lower dew-point temperature and better anti-condensation performance than a traditional plate-type radiant panel. The characteristics of the radiation and convection heat transfer of the RIDU were studied. The total heat exchange of the RIDU can be 16.5% greater than that of the traditional plate-type radiant terminal.

  15. Calculational experimental examination and ensuring of equipment and pipelines seismic resistance at starting and operating water-cooled and moderated reactor WWER-type NPPs. Final report

    International Nuclear Information System (INIS)

    1999-01-01

    The results of testing of equipment at Bohunice NPP and pipeline systems at Unit 3 of Kozloduy NPP (WWER-440 type reactors) are presented in this Final Report. These results side by side with experimental values of natural frequencies and decrements also include experimental data about vibration modes of tested equipment and pipelines. For the first time the results of new calculational-experimental examination of equipment seismic resistance at Unit 2 of Armenian NPP are presented. At Kozloduy NPP direction's request the planed additional tests of some selected items were put off on 1997. Instead of postponed tests we carried out detailed analysis of our past inspections of numerous equipment seismic resistance at the Unit 5 of Kozloduy NPP. Experimental data with results of additional analysis are presented

  16. Heat exchanger with dirt separator for the use of the heat energy of waste water

    Energy Technology Data Exchange (ETDEWEB)

    1975-11-13

    Well-known heat exchanger systems consist of separate heat exchangers and dirt separators. In the case here in question both devices form a unit. A finned tube heat exchanger is positioned in the center of the dirt separator and is given extra protection through deflection sheets. A safety overflow is supplied so that no residue can appear in the waste water line when decanting.

  17. Force Structure: Restructuring and Rebuilding the Army Will Cost Billions of Dollars for Equipment but the Total Cost Is Uncertain

    National Research Council Canada - National Science Library

    St. Laurent, Janet A

    2008-01-01

    .... Several factors are contributing to the uncertainties about future costs. First, the Army's $43.6 funding plan for equipping modular units was based on preliminary modular unit designs and did not fully consider the needs of National Guard units...

  18. Continuous regeneration ion exchange column, especially for separation of usable component in metallurgy

    International Nuclear Information System (INIS)

    Sokola, K.; Thelen, V.

    1982-01-01

    A pulsating pump is connected to the bottom part of the ion exchange column connected to a storage vessel equipped with a level indicator and a siphon overflow. In the central part of the column, i.e., in its feed tube there is an ejector with a controlled inlet. To the bottom part of the column are connected two tubings of which the delivery pipe is connected via a one-way closing valve at the outlet of the pulsating pump while the feed pipe is connected via the automatically controlled valve at the inlet of the pulsating pump and to the storage vessel. The improvement of the equipment consists in that a control block equipped with a timing relay is connected to the indicator. Control transfer pathways have been built between the control block and the automatically controlled valve and the pulsating pump. Another improvement is in that a conical resin storage bin equipped with an indicator showing its content is connected to the feed pipe. (B.S.)

  19. 46 CFR 185.740 - Periodic servicing of hydrostatic release units.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Periodic servicing of hydrostatic release units. 185.740... Equipment § 185.740 Periodic servicing of hydrostatic release units. (a) Each hydrostatic release unit... specified by the Commandant. (b) Each disposable hydrostatic release unit must be marked with an expiration...

  20. The fluoride content of an anion exchange resin in the fluoride form

    International Nuclear Information System (INIS)

    Kleijn, J.P. de; Zanten, B. van

    1977-01-01

    The fluoride content of an anion exchange resin in the F - -form depends on the material of the equipment used for the preparation. If a glass equipment is used too much fluorine is introduced. The experimental results are explained by taking into account a competition of F - and SiF 6 2- for the hydroxyl positions of the resin (OH - ). Because SiF 6 2- is bivalent and has a lower hydration energy than F - , the resin has a much larger affinity for this species than for F - . If a higher concentration of SiF 6 2- is generated by an intensive contact of the HF solution with glass, two OH-groups may be replaced by one SiF 6 2- . This results in a resin with 3 times as much fluorine as calculated from the chloride capacity. If the formation of SiF 6 2- is impossible as for example in teflon equipment, the same capacity is obtained for chloride and fluoride. (T.G.)

  1. Compliance testing of medical diagnostic x-ray equipment: three years experience of a public hospital in western Australia

    International Nuclear Information System (INIS)

    Tuchyna, T.; Jacob, C.S.

    2000-01-01

    Full text: A formal compliance testing program which began on 1 January 1997 called for all medical and diagnostic x-ray equipment to be tested according to protocols established by the Western Australian Radiological Council. This work describes the impact of the legislation three years post implementation on a major teaching Hospital with 45 x-ray tubes located throughout 37 rooms. Testing is performed prior to scheduled service by licensed compliance testers according to test methods specified in the Western Australian Compliance Testing Workbook, 1997. A dedicated non-invasive x-ray beam analyser is instrumental in accurately determining radiation output parameters of the generator and x-ray tube. Assessment of compliance is determined by a Qualified Expert. Repair and re-testing of non-compliant items is coordinated with service personnel. Notices of non-compliance were received for approximately 60% of the equipment in the Hospital following the equipment' first annual test. Reasons and seriousness of failure varied according to equipment category, test category, equipment use and age. The majority of non-compliance issues were resolved within 90 days. At the end of the third year of testing, approximately 75% of the x-ray units tested met the compliance criteria. The main reasons for non-compliance were found to be design limitations associated with old technology and the current radiation legislation that makes it difficult for older equipment to meet the stringent criteria. The number and categories of failure did not significantly decrease in the second or third years of testing. Exemptions from compliance criteria have been sought for two units on the basis of age and design. Units unable to meet the criteria following several repair attempts or where the cost of repair was deemed not justified, were decommissioned. Formal testing of medical x-ray equipment has demonstrated various non-compliance issues that did not significantly improve during the

  2. Theory, Practice and Policy: A Longitudinal Study of University Knowledge Exchange in the UK

    Science.gov (United States)

    Zhang, Qiantao

    2018-01-01

    This article examines the progress of university knowledge exchange in the United Kingdom over a decade, linking theory, practice and policy. As indicated by the literature, the performance of university knowledge exchange is influenced by institutional and locational characteristics. Data on 133 UK universities between 2003-2004 and 2012-2013 are…

  3. A Knowledge-Based Approach to Automatic Detection of Equipment Alarm Sounds in a Neonatal Intensive Care Unit Environment.

    Science.gov (United States)

    Raboshchuk, Ganna; Nadeu, Climent; Jancovic, Peter; Lilja, Alex Peiro; Kokuer, Munevver; Munoz Mahamud, Blanca; Riverola De Veciana, Ana

    2018-01-01

    A large number of alarm sounds triggered by biomedical equipment occur frequently in the noisy environment of a neonatal intensive care unit (NICU) and play a key role in providing healthcare. In this paper, our work on the development of an automatic system for detection of acoustic alarms in that difficult environment is presented. Such automatic detection system is needed for the investigation of how a preterm infant reacts to auditory stimuli of the NICU environment and for an improved real-time patient monitoring. The approach presented in this paper consists of using the available knowledge about each alarm class in the design of the detection system. The information about the frequency structure is used in the feature extraction stage, and the time structure knowledge is incorporated at the post-processing stage. Several alternative methods are compared for feature extraction, modeling, and post-processing. The detection performance is evaluated with real data recorded in the NICU of the hospital, and by using both frame-level and period-level metrics. The experimental results show that the inclusion of both spectral and temporal information allows to improve the baseline detection performance by more than 60%.

  4. Development of ultrasonic testing equipment incorporating electromagnetic acoustic transducer

    International Nuclear Information System (INIS)

    Sato, Michio; Kimura, Motohiko; Okano, Hideharu; Miyazawa, Tatsuo; Nagase, Koichi; Ishikawa, Masaaki

    1989-01-01

    An ultrasonic testing equipment for use in in-service inspection of nuclear power plant piping has been developed, which comprises an angle-beam electromagnetic acoustic transducer mounted on a vehicle for scanning the piping surface to be inspected. The transducer functions without direct contact with the piping surface through couplant, and the vehicle does not require a guide track installed on the piping surface, being equipped with magnetic wheels that adhere to the piping material, permitting it to travel along the circumferential weld joint of a carbon steel pipe. The equipment thus dispenses with the laborious manual work involved in preparing the piping for inspection, such as removal of protective coating, surface polishing and installation of guide track and thereby considerably reduces the duration of inspection. The functioning principle and structural features of the transducer and vehicle are described, together with the results of trial operation of a prototype unit, which proved a 1mm deep notch cut on a test piece of 25mm thick carbon steel plate to be locatable with an accuracy of ±2mm. (author)

  5. CONTINUOUS MODELING OF FOREIGN EXCHANGE RATE OF USD VERSUS TRY

    Directory of Open Access Journals (Sweden)

    Yakup Arı

    2011-01-01

    Full Text Available This study aims to construct continuous-time autoregressive (CAR model and continuous-time GARCH (COGARCH model from discrete time data of foreign exchange rate of United States Dollar (USD versus Turkish Lira (TRY. These processes are solutions to stochastic differential equation Lévy-driven processes. We have shown that CAR(1 and COGARCH(1,1 processes are proper models to represent foreign exchange rate of USD and TRY for different periods of time February 2002- June 2010.

  6. Constructal design of finned tubes used in air-cooled heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Shokouhmand, Hossein; Mahjoub, Shoeib [University of Tehran, Tehran (Iran, Islamic Republic of); Salimpour, Mohammad Reza [Isfahan University of Technology, Isfahan (Iran, Islamic Republic of)

    2014-06-15

    The present study documents the constructal design and optimization of finned tubes used in air-cooled heat exchangers. The considered tubes are equipped with annular fins. The aim is to minimize the overall thermal resistance by morphing the geometry. The geometrical and thermo-physical parameters considered are the number of fins, ratio of fin height to tube diameter, Stanton number, ratio of fin conductivity to air conductivity, ratio of in-tube fluid conductivity to air conductivity and dimensionless pressure drop. Two constraints are applied in the optimization process: fixed overall volume of heat exchanger and fixed volume fraction of fin material. It is found that there exist optimal values for the number and the height of fins. Moreover, the optimal heat transfer has an extremum in a special volume fraction of fin material.

  7. Constructal design of finned tubes used in air-cooled heat exchangers

    International Nuclear Information System (INIS)

    Shokouhmand, Hossein; Mahjoub, Shoeib; Salimpour, Mohammad Reza

    2014-01-01

    The present study documents the constructal design and optimization of finned tubes used in air-cooled heat exchangers. The considered tubes are equipped with annular fins. The aim is to minimize the overall thermal resistance by morphing the geometry. The geometrical and thermo-physical parameters considered are the number of fins, ratio of fin height to tube diameter, Stanton number, ratio of fin conductivity to air conductivity, ratio of in-tube fluid conductivity to air conductivity and dimensionless pressure drop. Two constraints are applied in the optimization process: fixed overall volume of heat exchanger and fixed volume fraction of fin material. It is found that there exist optimal values for the number and the height of fins. Moreover, the optimal heat transfer has an extremum in a special volume fraction of fin material.

  8. Improving the effectiveness of boiler units with coal dust systems equipped with mill-ventilators

    Science.gov (United States)

    Elsukov, V. K.

    2007-09-01

    Problems pertinent to controlling the load of steam boilers and coal dust systems equipped with mill-ventilators are analyzed. A comprehensive set of patented technical solutions for these problems is presented. A formula for determining the ventilation output of mill-ventilators as a function of the fuel charge is proposed.

  9. High pressure gas reinjection unit

    Energy Technology Data Exchange (ETDEWEB)

    1976-03-01

    Nuovo Pignone has built for gas reinjection at Ekofisk the highest pressure injection unit to date: suction pressure 246 bar, discharge 647 bar, for 5.7 million cu m/day of natural gas, and driven by a GE MS 5001 gas turbine of 24,000 hp. The barrel-type compressor has been used already in Algeria at Hassi Messaoud. Full scale tests have shown that the unit is satisfactory; special attention being paid to the stability of the rotor. Air cooled heat exchangers were used in the test loop to cool the discharge gas; at Ekofisk, heat exchangers with sea water will be used. The valves in the test loop were of a special, low- noise type. Vibrations of the rotor system and changes in gas pressure monitored, showing that a pressure of 680 bars can be achieved without instability. Economic considerations lead to preference for rotary compressors driven by gas turbines for similar applications in the exploitation of oil fields. A graph of the characteristics of the unit is given.

  10. RETRIEVAL EQUIPMENT DESCRIPTIONS

    International Nuclear Information System (INIS)

    J. Steinhoff

    1997-01-01

    The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) retrieval from the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. There are no quality assurance requirements or QA controls in this document. Retrieval under normal conditions is accomplished with the same fleet of equipment as is used for emplacement. Descriptions of equipment used for retrieval under normal conditions is found in Emplacement Equipment Descriptions, DI: BCAF00000-01717-5705-00002 (a document in progress). Equipment used for retrieval under abnormal conditions is addressed in this document and consists of the following: (1) Inclined Plane Hauler; (2) Bottom Lift Transporter; (3) Load Haul Dump (LHD) Loader; (4) Heavy Duty Forklift for Emplacement Drifts; (5) Covered Shuttle Car; (6) Multipurpose Vehicle; and (7) Scaler

  11. Revitalization of Tuzla Thermal Power Plant's Unit 3 (100 MW)

    International Nuclear Information System (INIS)

    Sakovic, A.; Praso, N.

    1998-01-01

    Power Plant Revitalization is a highly ranged concept essentially aimed at continued operations of the generating unit at, or near, rated capacities for the rest of the economic life of the plant or even for an extended life. In essence, the need to rehabilitate may arise due to reasons such as low availability factor, low efficiency, increasing operating and maintenance costs, loss of reliability, drop in safety of plant and personnel, poor maintainability or environmental requirements. The term revitalization is therefore normally used in the context to cover the range of activities including repairing components, replacing equipment, modifying systems, adding new system and equipment and perhaps restoration to rated capacities. This exercise on already complex power generation process will naturally require the application of various technologies in order to ensure a safe and efficient installation of electricity supply. In normal conditions of producing and consumption of electricity (load demands) in order to answer the question of what kind of revitalization to undertake it is necessary to state at the very beginning: - whether it is necessary, from the point of equipment wear-out, to revitalize all equipment at once (one-phase revitalization), or - whether it is possible to postpone the revitalization of a part of equipment for the next period (phased revitalization). Both concepts have some specific advantages and disadvantages. In essence the decision-making process between these two approaches, three basic conditions should be considered: technical-technological adequacy, energy-economy adequacy and financial adequacy. This paper covers general considerations, approach and methodology implemented during the revitalization the Tuzla Thermal Power Plant's Unit 3 (100MW) which was imposed by urgent demands of the Power System, the war conditions and financial possibilities including: - General data on TPP Tuzla and Unit 3 - Scope of work and economic effects

  12. Seasonal unit roots in trade variables

    OpenAIRE

    Carol Alexander; Manuel Cantavella Jordá

    1997-01-01

    In this paper we examine the presence of seasonal unit roots in trade variables for Germany, France, the United Kingdom, and Italy, using the procedure developed by Hylleberg, Engle, Granger, and Yoo (1990) [HEGY]. Both quarterly and monthly data reject the presence of unit roots at most seasonal frequencies, more frequently in quarterly than in monthly data. This has important implications for econometric modeling of trade balance, exchange rates and income in European Union (EU) countries. ...

  13. Modeling the performance of hydrogen-oxygen unitized regenerative proton exchange membrane fuel cells for energy storage

    Science.gov (United States)

    Guarnieri, Massimo; Alotto, Piergiorgio; Moro, Federico

    2015-11-01

    Thanks to the independent sizing of power and energy, hydrogen-based energy storage is one of the very few technologies capable of providing long operational times in addition to the other advantages offered by electrochemical energy storage, for example scalability, site versatility, and mobile service. The typical design consists of an electrolyzer in charge mode and a separate fuel cell in discharge mode. Instead, a unitized regenerative fuel cell (URFC) is a single device performing both energy conversions, achieving a higher compactness and power-to-weight ratio. This paper presents a performance model of a URFC based on a proton exchange membrane (PEM) electrolyte and working on hydrogen and oxygen, which can provide high energy and power densities (>0.7 W cm-2). It provides voltage, power, and efficiency at varying load conditions as functions of the controlling physical quantities: temperature, pressure, concentration, and humidification. The model constitutes a tool for designing the interface and control sub-system as well as for exploring optimized cell/stack designs and operational conditions. To date, only a few of such analyses have been carried out and more research is needed in order to explore the true potential of URFCs.

  14. Compact Design of 10 kW Proton Exchange Membrane Fuel Cell Stack Systems with Microcontroller Units

    Directory of Open Access Journals (Sweden)

    Hsiaokang Ma

    2014-04-01

    Full Text Available In this study, fuel, oxidant supply and cooling systems with microcontroller units (MCU are developed in a compact design to fit two 5 kW proton exchange membrane fuel cell (PEMFC stacks. At the initial stage, the testing facility of the system has a large volume (2.0 m × 2.0 m × 1.5 m with a longer pipeline and excessive control sensors for safe testing. After recognizing the performance and stability of stack, the system is redesigned to fit in a limited space (0.4 m × 0.5 m × 0.8 m. Furthermore, the stack performance is studied under different hydrogen recycling modes. Then, two similar 5 kW stacks are directly coupled with diodes to obtain a higher power output and safe operation. The result shows that the efficiency of the 5 kW stack is 43.46% with a purge period of 2 min with hydrogen recycling and that the hydrogen utilization rate µf is 66.31%. In addition, the maximum power output of the twin-coupled module (a power module with two stacks in electrical cascade/parallel arrangement is 9.52 kW.

  15. Efficiency of the Foreign Exchange Market of Papua New Guinea During the Recent Float

    OpenAIRE

    Guneratne Banda Wickremasinghe

    2004-01-01

    This paper examines the validity of the efficient market hypothesis (EMH) for the foreign exchange market of Papua New Guinea (PNG) using data on spot exchange rates for four major foreign currencies during the recent float. The unit root test results indicate that all the four exchange rates are random walks supporting the weak-form of the EMH. However, the Johansen multivariate cointegration test, the Granger causality test and variance decomposition analysis provide evidence that there are...

  16. Do central banks respond to exchange rate movements? Some new evidence from structural estimation

    OpenAIRE

    Wei Dong

    2013-01-01

    This paper investigates the impact of exchange rate movements on the conduct of monetary policy in Australia, Canada, New Zealand and the United Kingdom. We develop and estimate a structural general equilibrium two-sector model with sticky prices and wages and limited exchange rate pass-through. Different specifications for the monetary policy rule and the real exchange rate process are examined. The results indicate that the Reserve Bank of Australia, the Bank of Canada and the Bank of Engla...

  17. Data communication equipment

    International Nuclear Information System (INIS)

    Kim, Hak Seon; Lee, Sang Mok

    1998-02-01

    The contents of this book are introduction of data communication on definition, purpose and history, information terminal about data communication system and data transmission system, data transmit equipment of summary, transmission cable, data port, concentrator and front-end processor, audio communication equipment like phones, radio communication equipment of summary on foundation of electromagnetic waves, AM transmitter, AM receiver, FM receiver and FM transmitter, a satellite and mobile communication equipment such as earth station, TT and C and Cellular phone, video telephone and new media apparatus.

  18. Medical equipment management

    CERN Document Server

    Willson, Keith; Tabakov, Slavik

    2013-01-01

    Know What to Expect When Managing Medical Equipment and Healthcare Technology in Your Organization As medical technology in clinical care becomes more complex, clinical professionals and support staff must know how to keep patients safe and equipment working in the clinical environment. Accessible to all healthcare professionals and managers, Medical Equipment Management presents an integrated approach to managing medical equipment in healthcare organizations. The book explains the underlying principles and requirements and raises awareness of what needs to be done and what questions to ask. I

  19. Site investigation equipment developed by Teollisuuden Voima Oy

    International Nuclear Information System (INIS)

    Oehberg, A.

    1991-02-01

    Teollisuuden Voima Oy (TVO) carries out site investigations in Finland for final disposal of nuclear high level waste during 1987-2000. In order to carry out the investigations some essential equipment have been designed and constructed. The biggest insufficiency among different measuring methods was among water sampling and hydraulic testing. There are some common specifications which all of these equipment has to fulfil. The two most important are that they have to be operatable in deep slim boreholes down to 1000 meters depth with 56 mm in diameter. The main purpose of the Hydraulic Testing Unit is to determine hydraulic conductivity in crystalline rock, where water can flow primarily through fractures. In most commonly used configurations, measurement range is from 10 - 11 to 10 - 5 m/s with constant-head method. Although constant-head method is principally used, almost any known hydraulic method is possible with existing hardware. Most functions are controlled by the computer. The whole system is built into an electrically heated trailer. The system consists of inflatable packers, stainless steel rods, pressure transducers and datalogging devices. The maximum number of monitoring sections is seven. In addition to that as many blind sections as is needed to prevent vertical flow in boreholes can be installed. Water sampling is possible either with a double packer method or in conjunction with the hydraulic head monitoring equipment. The first possibility involves using the laboratory trailer and the second one using a separate pumping unit plus the laboratory trailer in a later phase when sampling is to be conducted. In the laboratory trailer there are all the measuring devices needed to control different chemical parameters (pH, Eh, pS, O 2 , conductivity and temperature) during pumping

  20. Industry sector analysis, Mexico: Electric power production and distribution equipment. Export Trade Information

    International Nuclear Information System (INIS)

    Wood, J.S.; Miller, R.W.

    1988-09-01

    The Industry Sector Analyses (I.S.A.) for electric power production and distribution equipment contains statistical and narrative information on projected market demand, end-users, receptivity of Mexican consumers to U.S. products, the competitive situation - Mexican production, total import market, U.S. market position, foreign competition, and competitive factors, and market access - Mexican tariffs, non-tariff barriers, standards, taxes and distribution channels. The I.S.A. provides the United States industry with meaningful information regarding the Mexican market for electric power production and distribution equipment

  1. Ageing Management Programme: An Experience of In-Service Inspection of the Kartini Heat Exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Nitiswati, S., E-mail: nitis@batan.go.id [Centre for Reactor Technology and Nuclear Safety, National Nuclear Energy Agency (BATAN), Jakarta (Indonesia); Syarip,; Tjiptono, T.; Wantana, [Centre for Accelerator and Material Process Technology, National Nuclear Energy Agency (BATAN), Yogyakarta (Indonesia)

    2014-08-15

    This paper discusses an experience on ISI of the Kartini reactor heat exchanger, as part of the implementation of an ageing management programme. Kartini reactor is located in Yogyakarta, Indonesia. The heat exchanger was constructed for 250 kW capacity. The type of heat exchanger is shell with tube recirculation. Tube material is stainless steel 304, and the shell and baffle plate materials are carbon steel. The heat exchanger has 72 tubes, its outer and inner diameters respectively are 19 and 16 mm, and tube thickness is 1.5 mm. The aim of ISI was to obtain and evaluate the heat exchanger’s condition including the detection of any possible local tube thinning, pitting corrosion or gradual thinning, and determine whether any degradation or deterioration of the heat exchanger could have a significant impact to safety. The heat exchanger was inspected utilizing eddy current equipment in 2003 and 2006. Inspection results in 2003 determined that 12 heat exchanger tubes have a thinning degradation level ranging from 10% up to 60% of the outer diameter due to pitting corrosion. Deterioration of baffle plates has been linked to general corrosion attack. Inspection results in 2006 showed a consistent thinning degradation level with the previous inspection in 2003. So far heat exchanger performance is still satisfactory, as defined by the transfer of primary heat for a 2°C difference between inlet and outlet as required. (author)

  2. Supervision of the thermal performance of heat exchanger trains

    Energy Technology Data Exchange (ETDEWEB)

    Negrao, C.O.R.; Tonin, P.C.; Madi, M. [Federal University of Technology Parana UTFPR, Post-graduate Program in Mechanical and Materials Engineering PPGEM, Thermal Science Laboratory LACIT, Av. Sete de Setembro, 3165, CEP 80230-901, Curitiba, Parana (Brazil)

    2007-02-15

    In oil refining, heat exchanger networks are employed to recover heat and therefore save energy of the plant. However, many heat exchangers in crude oil pre-heat trains are under high risk of fouling. Under fouling conditions, the thermal performance of heat exchangers is continuously reduced and its supervision becomes an important task. The large number of heat exchangers in pre-heat trains and the change of operation conditions and feedstock charges make the daily supervision a difficult task. This work applies an approach to follow the performance of heat exchangers [M.A.S. Jeronimo, L.F. Melo, A.S. Braga, P.J.B.F. Ferreira, C. Martins, Monitoring the thermal efficiency of fouled heat exchangers - A simplified method, Experimental Thermal and Fluid Science 14 (1997) 455-463] and extends it to monitor the whole train. The approach is based on the comparison of measured and predicted heat exchanger effectiveness. The measured value is computed from the four inlet and outlet temperatures of a heat exchanger unit. The predicted clean and dirty values of effectiveness are calculated from classical literature relations as a function of NTU and of heat capacity ratio (R). NTU and R are continuously adjusted according to mass flow rate changes. An index of fouling is defined for the whole network and the results show the performance degradation of the network with time. The work also suggests that Jeronimo's index of fouling can be used to estimate the fouling thermal resistance of heat exchangers. (author)

  3. Ecologically unequal exchange, recessions, and climate change: A longitudinal study.

    Science.gov (United States)

    Huang, Xiaorui

    2018-07-01

    This study investigates how the ecologically unequal exchange of carbon dioxide emissions varies with economic recessions. I propose a country-specific approach to examine (1) the relationship between carbon dioxide emissions in developing countries and the "vertical flow" of exports to the United States; and (2) the variations of the relationship before, during, and after two recent economic recessions in 2001 and 2008. Using data on 69 developing nations between 2000 and 2010, I estimate time-series cross-sectional regression models with two-way fixed effects. Results suggest that the vertical flow of exports to the United States is positively associated with carbon dioxide emissions in developing countries. The magnitude of this relationship increased in 2001, 2009, and 2010, and decreased in 2008, but remained stable in non-recession periods, suggesting that economic recessions in the United States are associated with variations of ecologically unequal exchange. Results highlight the impacts of U.S. recessions on carbon emissions in developing countries through the structure of international trade. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Floppy disc units for data collection from neutron beam experiments

    International Nuclear Information System (INIS)

    Hall, J.W.

    1976-02-01

    The replacement of paper tape output facilities on neutron beam equipment on DIDO and PLUTO reactors by floppy discs will improve reliability and provide a more manageable data storage medium. The cost of floppy disc drives is about the same as a tape punch and printer and less than other devices such as a magnetic tape. Suitable floppy disc controllers are not at present available and a unit was designed as a directly pluggable replacement for paper tape punches. This design was taken as the basis in the development of a prototype unit for use in neutron beam equipment. The circuit operation for this prototype unit is described. (author)

  5. Colloquium paper: adaptive specializations, social exchange, and the evolution of human intelligence.

    Science.gov (United States)

    Cosmides, Leda; Barrett, H Clark; Tooby, John

    2010-05-11

    Blank-slate theories of human intelligence propose that reasoning is carried out by general-purpose operations applied uniformly across contents. An evolutionary approach implies a radically different model of human intelligence. The task demands of different adaptive problems select for functionally specialized problem-solving strategies, unleashing massive increases in problem-solving power for ancestrally recurrent adaptive problems. Because exchange can evolve only if cooperators can detect cheaters, we hypothesized that the human mind would be equipped with a neurocognitive system specialized for reasoning about social exchange. Whereas humans perform poorly when asked to detect violations of most conditional rules, we predicted and found a dramatic spike in performance when the rule specifies an exchange and violations correspond to cheating. According to critics, people's uncanny accuracy at detecting violations of social exchange rules does not reflect a cheater detection mechanism, but extends instead to all rules regulating when actions are permitted (deontic conditionals). Here we report experimental tests that falsify these theories by demonstrating that deontic rules as a class do not elicit the search for violations. We show that the cheater detection system functions with pinpoint accuracy, searching for violations of social exchange rules only when these are likely to reveal the presence of someone who intends to cheat. It does not search for violations of social exchange rules when these are accidental, when they do not benefit the violator, or when the situation would make cheating difficult.

  6. Evaluation of conventional x-ray diagnostic equipment and radiological protection systems of hospitals and clinics installed in Recife city, Brazil

    International Nuclear Information System (INIS)

    Passos, Robson Silva

    1999-05-01

    Diagnostic radiology is the main contributor to the man-made exposure of general population. Since Quality Assurance (QA) programs ensure high quality diagnostic images with the lowest possible radiation dose to the patient, it has been recommended that all introduce QA programs for their radiological facilities. Consequently it is important to check the adequacy of equipment operating parameters in diagnostic radiography facilities, to ensure that a high quality of service is delivered. The purpose of this study was to evaluate the operating conditions of diagnostic units installed in Recife, Pernambuco. The study included 31 X-ray units from both public and private diagnostic services. The following parameters were evaluated: coincidence between the luminous and radiation fields; alignment of the radiation beam; agreement between the real and preset values of kVp and exposure time; filtration; half value lower (HVL); luminance of the view box; uniformity of the luminance; illuminance of the environment. The results showed that 20% of the equipment surveyed exhibited discrepancies between the luminous and radiation fields greater than 2% of the source to skin distance. The test of kilovoltage showed that 48% of the units do not fulfill the acceptability criteria, presenting discrepancies higher than ± 10% between the measured and preset values. The results of the accuracy of the timer indicated that 81% of the equipment surveyed present a discrepancy greater than ± 10% between the time selected in the control panel and actual exposure time.The test of the filtration shown that, in 20% of the equipment, this was inferior to 2,5 mm Al. The test of the luminance of view box shown that 96% of the equipment, shown a luminance lower of 2.000 cd/m 2 . Related to the test of the uniformity of the luminance, 81 % of the equipment shown a variation of the uniformity higher then 10%. The test of the iluminancy of the environment shown that 61 % of the equipment presented

  7. Disaster Response Preparedness and Training: A Capabilities Assessment of the Asia Pacific Military Health Exchange

    Science.gov (United States)

    2018-02-01

    responses revealed major themes of need for additional training in leadership /communication, austere/realistic training environment, interoperability...casualties. Since the military is best equipped to manage global operations, medical military members of the Indo-Asia Pacific nations initiated efforts...three previously separate medical, nursing, and leadership information exchanges into a single event. APHME was developed to foster information and

  8. 77 FR 50742 - Self-Regulatory Organizations; New York Stock Exchange LLC; Order Approving a Proposed Rule...

    Science.gov (United States)

    2012-08-22

    ... multiples of six (e.g., six, twelve, eighteen or twenty-four cross connects). The Exchange proposes to... monthly to furnish and install one cross connect between cabinets. For a bundle of six cross connects, the... differentiation among Users regarding the fees charged for a particular product, service or piece of equipment. In...

  9. Study on Pressure drop for Ion Exchanger in Jordan Research and Training Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ki-jung; Choi, Jungwoon; Kim, Seong-Hoon; Chi, Dae-Young; Park, Cheol [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The Jordan Research and Training Reactor (JRTR) is currently being constructed and commissioned in the JUST (Jordan University of Science and Technology) site. The main fluid systems relevant to the JRTR have been proceeding at the Korea Atomic Energy Research Institute. In order to achieve the purpose of the pool water purification, two filters and two ion exchangers which can be to remove suspended solids and ionic impurities in the in-taken pool water have been designed. For the reliable design of this system pump, it is important to predict the pressure drop of the system equipment including the ion exchanger. In this study, the pressure drop in the ion exchanger of PWMS is predicted by using the well-known model and the results provided from manufacturing company. And, the calculated results are compared to the actual data which is measured from the ion exchanger during the PWMS commissioning. The predicted pressure drop is dominated by the resin bed as a portion of about 85% for total pressure drop. The predicted pressure drop is compared to the measured pressure drop of the ion exchanger which is installed in the JRTR, the data above 5 kg/s agree within 5% in the entire range.

  10. Enhanced Master Controller Unit Tester

    Science.gov (United States)

    Benson, Patricia; Johnson, Yvette; Johnson, Brian; Williams, Philip; Burton, Geoffrey; McCoy, Anthony

    2007-01-01

    The Enhanced Master Controller Unit Tester (EMUT) software is a tool for development and testing of software for a master controller (MC) flight computer. The primary function of the EMUT software is to simulate interfaces between the MC computer and external analog and digital circuitry (including other computers) in a rack of equipment to be used in scientific experiments. The simulations span the range of nominal, off-nominal, and erroneous operational conditions, enabling the testing of MC software before all the equipment becomes available.

  11. A multifractal analysis of Asian foreign exchange markets

    Science.gov (United States)

    Oh, G.; Eom, C.; Havlin, S.; Jung, W.-S.; Wang, F.; Stanley, H. E.; Kim, S.

    2012-06-01

    We analyze the multifractal spectra of daily foreign exchange rates for Japan, Hong-Kong, Korea, and Thailand with respect to the United States in the period from 1991 until 2005. We find that the return time series show multifractal spectrum features for all four cases. To observe the effect of the Asian currency crisis, we also estimate the multifractal spectra of limited series before and after the crisis. We find that the Korean and Thai foreign exchange markets experienced a significant increase in multifractality compared to Hong-Kong and Japan. We also show that the multifractality is stronger related to the presence of high values of returns in the series.

  12. Bench-Scale Studies with Argentine Ion Exchange Material

    International Nuclear Information System (INIS)

    Cicero-Herman, C.A.

    2002-01-01

    The United States Department of Energy (DOE), as well as international atomic energy commission, facilities use ion exchange materials for purification of aqueous streams in the nuclear industry. Unfortunately, the use of the ion exchange materials creates a waste stream that can be very high in both organic and radioactive constituents. Therefore, disposal of the spent resins often becomes an economic problem because of the large volumes of resin produced and the relatively few technologies that are capable of economically stabilizing this waste. Vitrification of this waste stream presents a reasonable disposable alternative because of its inherent destruction capabilities, the volume reductions obtainable, and the durable product that it produces

  13. Video equipment of tele dosimetry and audio

    International Nuclear Information System (INIS)

    Ojeda R, M.A.; Padilla C, I.

    2007-01-01

    To develop a work in an area with high radiation, it requires of a detailed knowledge of the surroundings work, a communication and effective vision, a near dosimetric control. In a work where the spaces variables and reduced accesses exist, noise that hinders the communication, defendant operative condition, radiation field and taking of decision, it is necessary to have tools that allow a total control of the environment to make opportune and effective decisions, there where the task is developed. Under this elementary concept, it was developed in the Laguna Verde Central a project that it allowed a mechanism, interactive of control in spaces complex; to see, to hear, to speak, to measure. This concept takes to the creation of an equipped system with closed circuit of television, wireless communication systems, tele dosimetry wireless systems, VHS and DVD recording equipment, uninterrupted energy units. The system requires of an electric power socket, and the installation of two cables by CCTV camera. The system is mobilized by a person. He puts on in operation in 5 minutes using a verification list. The concept was developed in the project denominated VETA-1, (Video Equipment of Tele dosimetry and Audio). It is objective of this work to present before the society the development of the VETA-1 tool that conclude in their first prototype in May of the present year. The VETA-1 project arises by a necessity of optimizing dose, it is an ALARA tool, with a countless applications, like it was proven in the 12 recharge stop of the Unit 1. The VETA-1 project integrate a recording system, with the primary end of analyzing in the place where the task is developed the details for an effective and opportune decision, but the resulting information is of utility for the personnel's training and the planning of future works. The VETA-1 system is an ALARA tool of quick response control. (Author)

  14. The root caused analysis of leakaged heat exchanger tube

    International Nuclear Information System (INIS)

    Shamsudin, Shaiful Rizam; Salleh, M.A.A. Mohd; Rahmat, Azmi; Anuar, Mohd Arif; Harun, Mohd; Zayid, Hafizal; Noor, Mazlee Mohd

    2015-01-01

    AISI type 316L stainless steel was used as a heat exchanger tube material in an inter-cooler column. After less than a year of operation, severe corrosion failures occurred and a transverse opening leakage was observed on one of the heat exchanger tubes. The failed tube was carefully analyzed using various metallurgical laboratory equipments. The root cause of the tube leakage was believed due to the presence of horizontal micro and macro pores as a hydrogen gas entrapment during casting of the parent ingot. The overlapped and gaping pores formed notch on the shell side of the tube surface, and it increasingly evident when the use of a high-energy water-jet and metal brush as cleaning procedure results in an establishment of pitting type local-action corrosion cells penetrated the tube wall. As a result, corrosive fluid in the tube side dissolved into the cooling water, accelerating the corrosion process.

  15. SLOPE STABILITY EVALUATION AND EQUIPMENT SETBACK DISTANCES FOR BURIAL GROUND EXCAVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    MCSHANE DS

    2010-03-25

    After 1970 Transuranic (TRU) and suspect TRU waste was buried in the ground with the intention that at some later date the waste would be retrieved and processed into a configuration for long term storage. To retrieve this waste the soil must be removed (excavated). Sloping the bank of the excavation is the method used to keep the excavation from collapsing and to provide protection for workers retrieving the waste. The purpose of this paper is to document the minimum distance (setback) that equipment must stay from the edge of the excavation to maintain a stable slope. This evaluation examines the equipment setback distance by dividing the equipment into two categories, (1) equipment used for excavation and (2) equipment used for retrieval. The section on excavation equipment will also discuss techniques used for excavation including the process of benching. Calculations 122633-C-004, 'Slope Stability Analysis' (Attachment A), and 300013-C-001, 'Crane Stability Analysis' (Attachment B), have been prepared to support this evaluation. As shown in the calculations the soil has the following properties: Unit weight 110 pounds per cubic foot; and Friction Angle (natural angle of repose) 38{sup o} or 1.28 horizontal to 1 vertical. Setback distances are measured from the top edge of the slope to the wheels/tracks of the vehicles and heavy equipment being utilized. The computer program utilized in the calculation uses the center of the wheel or track load for the analysis and this difference is accounted for in this evaluation.

  16. Slope Stability Evaluation And Equipment Setback Distances For Burial Ground Excavations

    International Nuclear Information System (INIS)

    Mcshane, D.S.

    2010-01-01

    After 1970 Transuranic (TRU) and suspect TRU waste was buried in the ground with the intention that at some later date the waste would be retrieved and processed into a configuration for long term storage. To retrieve this waste the soil must be removed (excavated). Sloping the bank of the excavation is the method used to keep the excavation from collapsing and to provide protection for workers retrieving the waste. The purpose of this paper is to document the minimum distance (setback) that equipment must stay from the edge of the excavation to maintain a stable slope. This evaluation examines the equipment setback distance by dividing the equipment into two categories, (1) equipment used for excavation and (2) equipment used for retrieval. The section on excavation equipment will also discuss techniques used for excavation including the process of benching. Calculations 122633-C-004, 'Slope Stability Analysis' (Attachment A), and 300013-C-001, 'Crane Stability Analysis' (Attachment B), have been prepared to support this evaluation. As shown in the calculations the soil has the following properties: Unit weight 110 pounds per cubic foot; and Friction Angle (natural angle of repose) 38 o or 1.28 horizontal to 1 vertical. Setback distances are measured from the top edge of the slope to the wheels/tracks of the vehicles and heavy equipment being utilized. The computer program utilized in the calculation uses the center of the wheel or track load for the analysis and this difference is accounted for in this evaluation.

  17. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  18. Knowledge exchange and learning from failures in distributed environments: The role of contractor relationship management and work characteristics

    International Nuclear Information System (INIS)

    Gressgård, Leif Jarle; Hansen, Kåre

    2015-01-01

    Learning from failures is vital for improvement of safety performance, reliability, and resilience in organizations. In order for such learning to take place in distributed environments, knowledge has to be shared among organizational members at different locations and units. This paper reports on a study conducted in the context of drilling and well operations on the Norwegian Continental Shelf, which represents a high-risk distributed organizational environment. The study investigates the relationships between organizations' abilities to learn from failures, knowledge exchange within and between organizational units, quality of contractor relationship management, and work characteristics. The results show that knowledge exchange between units is the most important predictor of perceived ability to learn from failures. Contractor relationship management, leadership involvement, role clarity, and empowerment are also important factors for failure-based learning, both directly and through increased knowledge exchange. The results of the study enhance our understanding of how abilities to learn from failures can be improved in distributed environments where similar work processes take place at different locations and involve employees from several companies. Theoretical contributions and practical implications are discussed. - Highlights: • We investigate factors affecting failure-based learning in distributed environments. • Knowledge exchange between units is the most important predictor. • Contractor relationship management is positively related to knowledge exchange. • Leadership involvement, role clarity, and empowerment are significant variables. • Respondents from an operator firm and eight contractors are included in the study

  19. HIGH ASPECT RATIO ION EXCHANGE RESIN BED - HYDRAULIC RESULTS FOR SPERICAL RESIN BEADS

    International Nuclear Information System (INIS)

    Duignan, M; Charles Nash, C; Timothy Punch, T

    2007-01-01

    A principal role of the DOE Savannah River Site is to safely dispose of a large volume of liquid nuclear waste held in many storage tanks. An in-tank ion exchange unit is being considered for cesium removal to accelerate waste processing. This unit is planned to have a relatively high bed height to diameter ratio (10:1). Complicating the design is the need to cool the ion exchange media; therefore, the ion exchange column will have a central cooling core making the flow path annular. To separate cesium from waste the media being considered is made of resorcinol formaldehyde resin deposited on spherical plastic beads and is a substitute for a previously tested resin made of crystalline silicotitanate. This spherical media not only has an advantage of being mechanically robust, but, unlike its predecessor, it is also reusable, that is, loaded cesium can be removed through elution and regeneration. Resin regeneration leads to more efficient operation and less spent resin waste, but its hydraulic performance in the planned ion exchange column was unknown. Moreover, the recycling process of this spherical resorcinol formaldehyde causes its volume to significantly shrink and swell. To determine the spherical media's hydraulic demand a linearly scaled column was designed and tested. The waste simulant used was prototypic of the wastes' viscosity and density. This paper discusses the hydraulic performance of the media that will be used to assist in the design of a full-scale unit

  20. Solution of operational problems utilization of an EX-IRT-2000 heat exchanger

    International Nuclear Information System (INIS)

    Razak, Abdu

    1986-01-01

    The Bandung TRIGA Mark II Reactor has been successfully operated for 21 years, especially in low power operation or as neutron sources for various experiments. Most of the operating time, approximately 80% of routine operation, was dedicated for radio-isotope production. During routine operation for radio-isotope production, the reactor could not be operated at full power. The reactor was operated at 60% of the maximum power (1 MWth) due to the inability of the original heat exchanger to operate properly. The reason is that slack deposition was built-up on the secondary side of the heat exchanger. Therefore, it reduced the coefficient of heat transfer considerably. To solve the problems, a set of heat exchanger including the pump was installed In parallel with the original unit. The heat exchanger was an IRT-2000 Reactor Heat exchanger which was collected from the abandoned IRT-2000 Project. The heat exchanger has capacity of 1.25 MW. The new heat exchanger could reduced the outlet temperature of the primary coolant Into 42 deg. C. While the original-heat exchanger at the worst condition and at 600 kW of power reach outlet temperature 49 deg. C. The IRT Heat Exchanger is a counter flow heat exchanger. (author)