WorldWideScience

Sample records for equilibrium radionuclide angiography

  1. Assessment of right ventricular afterload in mitral valve diseases with radionuclide angiography

    International Nuclear Information System (INIS)

    Shimizu, Mitsuharu; Nakagawa, Tomio; Kohno, Yoshihiro; Kuroda, Masahiro; Takeda, Yoshihiro; Hiraki, Yoshio; Nagaya, Isao; Senoh, Yoshimasa; Teramoto, Shigeru

    1991-01-01

    Right ventricular function at rest and during exercise was studied in 33 patients with mitral valve disease by equilibrium gated radionuclide angiography using 99m Tc in vivo labeled red blood cells. Radionuclide measurements of right ventricular ejection fraction (RVEF) were correlated with mean pulmonary arterial pressure (mPAP). RVEF decreased significantly with exercise. There was no significant correlation between RVEF at rest and mPAP. However, mPAP showed significant negative correlation with RVEF during exercise and with the changes of RVEF from rest to exercise. It is concluded that RVEF during exercise in mitral valve disease is affected by right ventricular afterload, and the measurements of RVEF at rest and during exercise by equilibrium gated radionuclide angiography is useful to assess right ventricular afterload. (author)

  2. Electrocardiograph-gated single photon emission computed tomography radionuclide angiography presents good interstudy reproducibility for the quantification of global systolic right ventricular function.

    Science.gov (United States)

    Daou, Doumit; Coaguila, Carlos; Vilain, Didier

    2007-05-01

    Electrocardiograph-gated single photon emission computed tomography (SPECT) radionuclide angiography provides accurate measurement of right ventricular ejection fraction and end-diastolic and end-systolic volumes. In this study, we report the interstudy precision and reliability of SPECT radionuclide angiography for the measurement of global systolic right ventricular function using two, three-dimensional volume processing methods (SPECT-QBS, SPECT-35%). These were compared with equilibrium planar radionuclide angiography. Ten patients with chronic coronary artery disease having two SPECT and planar radionuclide angiography acquisitions were included. For the right ventricular ejection fraction, end-diastolic volume and end-systolic volume, the interstudy precision and reliability were better with SPECT-35% than with SPECT-QBS. The sample sizes needed to objectify a change in right ventricular volumes or ejection fraction were lower with SPECT-35% than with SPECT-QBS. The interstudy precision and reliability of SPECT-35% and SPECT-QBS for the right ventricle were better than those of equilibrium planar radionuclide angiography, but poorer than those previously reported for the left ventricle with SPECT radionuclide angiography on the same population. SPECT-35% and SPECT-QBS present good interstudy precision and reliability for right ventricular function, with the results favouring the use of SPECT-35%. The results are better than those of equilibrium planar radionuclide angiography, but poorer than those previously reported for the left ventricle with SPECT radionuclide angiography. They need to be confirmed in a larger population.

  3. Evaluation with equilibrium radionuclide angiography of left ventricular systolic and diastolic function in pulmonary hypertension secondary to chronic pulmonary diseases

    International Nuclear Information System (INIS)

    Inoue, Kazuya; Sera, Kazuaki; Fukuzaki, Hisashi.

    1989-01-01

    To evaluate left ventricular systolic and diastolic function in patients with pulmonary hypertension secondary to chronic pulmonary diseases, 86 patients were studied using equilibrium radionuclide angiography with forward and reverse gating from the R wave. At rest left ventricular function, both in systolic and diastolic properties, in patients with pulmonary hypertension was significantly lower than in normal subjects (LVEF; P<0.05, PER; P<0.05, PFR; P<0.025, FF; P<0.025). During exercise left ventricular systolic function did not increase as much as in normals (LVEF; N.S., PER; N.S.). Left ventricular diastolic function during exercise was significantly lower than at rest (PFR; P<0.05, FF; P<0.001). The indices of left ventricular function obtained from radionuclide angiography had no close correlation with pulmonary hemodynamics or with blood gases. These results demonstrated that left ventricular dysfunction in patients with pulmonary hypertension was observed both at rest and during exercise, and might play an important role in reduced exercise tolerance. (author)

  4. Evaluation with equilibrium radionuclide angiography of left ventricular systolic and diastolic function in pulmonary hypertension secondary to chronic pulmonary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Kazuya; Sera, Kazuaki [National Akashi Hospital, Hyogo (Japan); Fukuzaki, Hisashi

    1989-08-01

    To evaluate left ventricular systolic and diastolic function in patients with pulmonary hypertension secondary to chronic pulmonary diseases, 86 patients were studied using equilibrium radionuclide angiography with forward and reverse gating from the R wave. At rest left ventricular function, both in systolic and diastolic properties, in patients with pulmonary hypertension was significantly lower than in normal subjects (LVEF; P<0.05, PER; P<0.05, PFR; P<0.025, FF; P<0.025). During exercise left ventricular systolic function did not increase as much as in normals (LVEF; N.S., PER; N.S.). Left ventricular diastolic function during exercise was significantly lower than at rest (PFR; P<0.05, FF; P<0.001). The indices of left ventricular function obtained from radionuclide angiography had no close correlation with pulmonary hemodynamics or with blood gases. These results demonstrated that left ventricular dysfunction in patients with pulmonary hypertension was observed both at rest and during exercise, and might play an important role in reduced exercise tolerance. (author).

  5. Increased left ventricular ejection fraction after a meal: potential source of error in performance of radionuclide angiography

    International Nuclear Information System (INIS)

    Brown, J.M.; White, C.J.; Sobol, S.M.; Lull, R.J.

    1983-01-01

    The effect of a standardized meal on left ventricular (LV) ejection fraction (EF) was determined by equilibrium radionuclide angiography in 16 patients with stable congestive heart failure but without pulmonary or valvular heart disease. LVEF was determined in the fasting state and 15, 30, and 45 minutes after a meal. Patients with moderately depressed fasting LVEF (30 to 50%), Group I, had a mean increase of 6.9 +/- 2.9% (p less than 0.005) in the LVEF at 45 minutes after the meal. Patients with severely depressed fasting LVEF (less than 30%), Group II, had no change after the meal. It is concluded that significant increases in LVEF may occur after meals in patients with moderate but not severe left ventricular dysfunction. Equilibrium radionuclide angiography studies that are not standardized for patients' mealtimes may introduce an important unmeasured variable that will affect the validity of data in serial studies of left ventricular function

  6. Increased left ventricular ejection fraction after a meal: potential source of error in performance of radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Brown, J.M.; White, C.J.; Sobol, S.M.; Lull, R.J.

    1983-06-01

    The effect of a standardized meal on left ventricular (LV) ejection fraction (EF) was determined by equilibrium radionuclide angiography in 16 patients with stable congestive heart failure but without pulmonary or valvular heart disease. LVEF was determined in the fasting state and 15, 30, and 45 minutes after a meal. Patients with moderately depressed fasting LVEF (30 to 50%), Group I, had a mean increase of 6.9 +/- 2.9% (p less than 0.005) in the LVEF at 45 minutes after the meal. Patients with severely depressed fasting LVEF (less than 30%), Group II, had no change after the meal. It is concluded that significant increases in LVEF may occur after meals in patients with moderate but not severe left ventricular dysfunction. Equilibrium radionuclide angiography studies that are not standardized for patients' mealtimes may introduce an important unmeasured variable that will affect the validity of data in serial studies of left ventricular function.

  7. Response of left ventricular volume to exercise in man assessed by radionuclide equilibrium angiography

    International Nuclear Information System (INIS)

    Slutsky, R.; Karliner, J.; Ricci, D.; Schuler, G.; Pfisterer, M.; Peterson, K.; Ashburn, W.

    1979-01-01

    To assess the effects of exercise on left ventricular volumes we studied 10 normal men, 15 patients with coronary disease who developed angina pectoris during exercise, and 10 patients with known coronary disease who did not develop angina during exercise. Each subject performed supine bicycle exercise under a mobile, single-crystal scintillation camera until angina or fatigue occurred. Technetium-99m bound to human serum albumin was the imaging agent. Data were collected at rest and during the last 2 minutes of each 3-minute stage of exercise and for 10 minutes after exercise. Volumes were calculated by a new radionuclide technique that correlated well with cineangiography and is expressed in nondimensional units. In normal subjects, the end-diastolic volume (EDV) at rest was not different from that a peak exercise. The end-systolic volume (ESV) decreased at peak exercise. ESV decreased progressively in all but two of 30 exercise periods. Angina patients had a larger EDV at rest and during chest pain than normals. Angina patients increased their ESV during chest pain resulting in a decreased ejection fraction (EF). All angina patients had a higher ESV during chest pain than during the exercise stage before chest pain. As a group, patients who did not develop angina had a lower EDV at rest and peak exercise than those who did develop angina. We conclude: that the EF increases during exercise due to a decrease in ESV; that the EF in patients with angina decreases because of an increase in ESV; and that the EF in coronary disease patients without angina shows no change because there is no significant change in the ESV. Radionuclide equilibrium angiography may prove useful for assessing EF and volume changes in patients with coronary artery disease

  8. Comparison of equilibrium radionuclide and contrast angiographic measurements of left ventricular peak ejection and filling rates and their time intervals

    Energy Technology Data Exchange (ETDEWEB)

    Sugrue, D.D.; Dickie, S.; Newman, H.; Myers, M.J.; Lavender, J.P.; McKenna, W.J. (Royal Postgraduate Medical School, London (UK))

    1984-10-01

    A comparison has been made of the equilibrium radionuclide and contrast angiographic estimates of normalized peak rates of ejection (PER) and filling (PFR) and their time intervals in twenty-one patients with cardiac disorders. Contrast angiographic and radionuclide measurements of left ventricular ejection fraction (LVEF), PER and PFR correlated well but time intervals correlated poorly. Mean values for radionuclide LVEF, PER and PFR were significantly lower and radionuclide time intervals were significantly longer compared to contrast angiography measurements.

  9. Comparison of two radionuclide ejection-fraction techniques with contrast angiography in ischemic heart disease and valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, I.M.; Abdel-Dayem, H.M.; Mohammed, M.M.J.; Simo, M.; Yousef, A.M.; Badruddosa, M.; Mahmood, A.R.; Sayed, M.E.

    1986-04-01

    First-pass radionuclide angiography (FPRA) in the 30/sup 0/ right anterior oblique and equilibrium gated radionuclide angiography (EGNA) in the 45/sup 0/ left anterior oblique were used for quantitative measurements of left ventricular ejection fraction (LVEF). Equipment used was a 400T gamma-camera interfaced with a Simis III Informatek computer. The results were compared with contrast angiography (CA). The aim of this study was to determine the sensitivity of both radionuclide techniques. The present data are based on 65 patients in whom CA and EGNA were performed. In 47 patients both FPRA and EGNA were performed. Results suggested that in ischemic heart disease (IHD) and valvular heart disease (VHD) the EGNA technique is well correlated with CA (r=0.9 and 0.73, respectively). FPRA correlated well only with CA in IHD (r=0.86), but not in VHD (r=0.18). This study indicates that both FPRA and EGNA are sensitive, noninvasive techniques for measuring ejection fraction in IHD, while in VHD, EGNA is more sensitive technique than FPRA.

  10. Evaluation of pulmonary hypertension using first-pass radionuclide angiography in patients with valvular heart disease

    International Nuclear Information System (INIS)

    Wang Xuemei; Shi Rongfang; Pan Shiwei; Fang Wei; Wang Daoyu; Wang Qi; Zhang Hailong

    2003-01-01

    Objective: To evaluate pulmonary hypertension (PH) using first-pass radionuclide angiography in patients with valvular heart disease. Methods: One hundred and forty patients (54 males, 86 females, average age of 44.75±10.84) with valvular disease were included in this study. Swan-Ganz thermodilution catheterization, echocardiography and first-pass radionuclide angiography were performed on all patients before surgery. Patients were divided into four groups: pulmonary artery pressure (PAP) normal group [mean PAP (MPAP)<20 mm Hg(1mm Hg=0.133 kPa)]; PAP slightly risen group (20 mm Hg≤MPAP<30 mm Hg); PAP moderately risen group (30 mm Hg≤MPAP<50 mm Hg); PAP highly risen group (MPAP≥50 mm Hg). Thirteen subjects with coronary heart disease and 40 normal subjects (36 males, 17 females, average age of 46.30±11.19) were included as control group. First-pass radionuclide angiography was performed on these subjects, Swan-Ganz thermodilution catheterization was performed on patients with coronary heart disease. Results: 1) Lung equilibrium time (LET) values by first-pass radionuclide angiography were (16.88±5.12), (15.89±4.69), (18.56±3.04), (25.37±5.89), (37.69±6.25) and (61.33±10.14) s in coronary heart disease group, normal subject group and four valvular heart disease groups, respectively. The differences were significant among four valvular heart disease groups; and among control group, PAP slightly risen group, PAP moderately risen group, PAP highly risen group (P<0.001). 2) Correlation coefficient between LET and MPAP from the afloat catheter manometer was 0.88 and between systolic PAP (SPAP) from echocardiography and SPAP from the afloat catheter manometer was 0.64. 3) Agreement was 71%, 78%, 81%, 100% between LET and MPAP in four valvular heart disease groups, respectively. 4) Sensitivity, specificity and accuracy of PAP using LET measuring was 85%, 79% and 83%, respectively. Conclusion: First-pass radionuclide angiography is an accurate and noninvasive

  11. A comparison of two radionuclide ejection-fraction techniques with contrast angiography in ischemic heart disease and valvular heart disease

    International Nuclear Information System (INIS)

    Hassan, I.M.; Abdel-Dayem, H.M.; Mohammed, M.M.J.; Simo, M.; Yousef, A.M.; Badruddosa, M.; Mahmood, A.R.; Sayed, M.E.

    1986-01-01

    First-pass radionuclide angiography (FPRA) in the 30 0 right anterior oblique and equilibrium gated radionuclide angiography (EGNA) in the 45 0 left anterior oblique were used for quantitative measurements of left ventricular ejection fraction (LVEF). Equipment used was a 400T gamma-camera interfaced with a Simis III Informatek computer. The results were compared with contrast angiography (CA). The aim of this study was to determine the sensitivity of both radionuclide techniques. The present data are based on 65 patients in whom CA and EGNA were performed. In 47 patients both FPRA and EGNA were performed. Results suggested that in ischemic heart disease (IHD) and valvular heart disease (VHD) the EGNA technique is well correlated with CA (r=0.9 and 0.73, respectively). FPRA correlated well only with CA in IHD (r=0.86), but not in VHD (r=0.18). This study indicates that both FPRA and EGNA are sensitive, noninvasive techniques for measuring ejection fraction in IHD, while in VHD, EGNA is more sensitive technique than FPRA. (orig.)

  12. Rest and exercise radionuclide angiography for diagnosis in chronic ischemic heart disease

    International Nuclear Information System (INIS)

    Gibbons, R.J.

    1991-01-01

    Rest and exercise radionuclide angiography is frequently employed for the diagnosis of chest pain syndromes. Its value and limitations in this regard have been well studied, but proper utilization of the technique requires an understanding of five critical concepts: (1) Radionuclide angiography is superior to treadmill exercise testing and probably equivalent to thallium scintigraphy, although the published series did not use current methods. (2) The true specificity of radionuclide angiography is about 80%, intermediate between the early optimistic estimates and the later pessimistic ones. (3) The peak exercise ejection fraction is the preferred test parameter for diagnosis, although exercise hemodynamics, symptoms, and electrocardiographic changes should also be considered. (4) Although radionuclide angiography is clearly helpful for noninvasive diagnosis, significant numbers of patients will continue to fall in an uncertain category. (5) The proper application of the technique requires recognition of its limitations and careful attention to technical details. When properly applied, this modality can make an important contribution to clinical decision making. 58 references

  13. Tomographic ventricular reconstruction using multiple view first-pass radionuclide angiography

    International Nuclear Information System (INIS)

    Lacy, J.L.; Ball, M.E.; Verani, M.S.; Wiles, H.; Roberts, R.

    1985-01-01

    In first-pass radionuclide angiography (FPRA) images of both left and right ventricles are uncontaminated by adjacent structures. Thus, the problem of tomographic reconstruction is vastly simplified compared to equilibrium blood pool imaging in which all structures are imaged simultaneously. Tomographic reconstruction from a limited number of views may thus be possible. A simple filtered interpolative back-projection reconstruction technique was employed. In this technique interpolation was used between sectional distributions at successive angles. Interpolations yielding 9 and 13 back projection angles of 22.5 0 and 15 0 were evaluated. Ventricular borders were obtained in each back-projected tomographic slice by location of the intensity level which provided correct total ventricular volume. Cast cross sections were quantitatively well represented by these borders. This ventricular border definition algorithm forms the basis for applications of the technique in animals and humans

  14. The post-ischemic ventricular dysfunction in PRINZMETAL's variant angina: Radionuclide evaluation

    International Nuclear Information System (INIS)

    Picozzi, R.; Palagi, B.; Baroffio, R.

    1987-01-01

    We studied by equilibrium radionuclide angiography 15 patients admitted to our coronary care unit because of PRINZMETAL's variant angina. Patients were examined mostly in the absence of symptoms. The incidence of ejection fraction abnormalities was low, while regional wall motion was always impaired at the site corresponding to ST-segment elevation at the time of the anginal attack. In 7 patients who underwent coronary angiography, we found an almost complete agreement between the site of atherosclerotic lesions and that of regional wall motion abnormalities. The patients were re-studied during intravenous perfusion of nitroglycerin: A detectable improvement of regional wall motion was found in 8 of them. We concluded that equilibrium radionuclide angiography appears to be a suitable tool for identifying reliably, in patients affected with PRINZMETAL's variant angina, the regional ventricular dysfunction remaining after the remission of symptoms in the presence of normalized ECG or signs of non-transmural ischemia. Equilibrium radionuclide angiography performed during nitroglycerin perfusion allowed us to evaluate in advance the importance of the vasospastic component and hence the efficacy of pharmacologic treatment. (orig.) [de

  15. Left ventricular function and visual phase analysis with equilibrium radionuclide angiography in patients with biventricular device

    International Nuclear Information System (INIS)

    Muxi, Africa; Setoain, Francisco J.; Pons, Francisca; Paredes, Pilar; Duch, Joan; Fuertes, Silvia; Ortin, Jaime; Mont, Lluis; Diaz-Infante, Ernesto

    2008-01-01

    Cardiac resynchronisation therapy (CRT) is a technique indicated in patients with moderate to severe heart failure and ventricular dyssynchrony. To evaluate left ventricular ejection fraction (LVEF) and synchronisation changes after CRT with a biventricular pacing implant, we used an equilibrium radionuclide angiography (ERNA). Fifty patients were studied. An ERNA was made 72 h and 6 months after the implant. Two acquisitions were performed: with the CRT device connected and after disconnecting it. In the follow-up, responders were defined as those who had improved in accordance with various clinical variables. Quantitative changes in LVEF and visual changes in synchronisation (phase analysis) were studied comparing the two studies and also comparing the connected and disconnected modes. At 6 months, 30 patients were defined as responders. LVEF increased significantly at 6 months compared with the 72-h study only in responders. At 72 h, the number of patients showing a decrease in LVEF (p < 0.05) or a synchronisation worsening after disconnecting the device was higher in responders than in nonresponders. At 6 months, 57% of responders had no synchronisation changes between the connected and disconnected modes, suggesting a resynchronisation process. ERNA permits the study of resynchronisation patients, showing a statistical LVEF improvement at 6 months. Moreover, visual phase analysis permits the study of the mechanism involved in the response, with an important number of responders with no changes between the two modes at 6 months. In the 72-h study, after disconnection of the device, LVEF and resynchronisation worsening can predict patient improvement at 6 months. (orig.)

  16. Prognostic value and limitations of exercise radionuclide angiography in medically treated coronary artery disease

    International Nuclear Information System (INIS)

    Taliercio, C.P.; Clements, I.P.; Zinsmeister, A.R.; Gibbons, R.J.

    1988-01-01

    We investigated whether exercise radionuclide angiography provides prognostic information in addition to that identified by resting left ventricular function and coronary anatomy in patients with medically treated coronary artery disease. Clinical follow-up (median, 21.7 months) was obtained in 424 medically treated patients who underwent exercise radionuclide angiography and coronary angiography. The mean age of the study population was 58 years, and 67% were men. Cardiac death occurred in 16 patients, nonfatal myocardial infarction in 16, and nonfatal out-of-hospital cardiac arrest in 1. Univariate analysis showed that multiple variables were associated with future cardiac events, including number of diseased vessels, exercise and rest radionuclide ejection fraction, history of myocardial infarction, exercise and rest left ventricular end-systolic and end-diastolic volume indices, peak exercise workload, age, abnormal resting electrocardiogram, and peak exercise ST-segment depression. Only three variables were independently associated with cardiac events on follow-up: number of diseased vessels, radionuclide ejection fraction at rest, and age. In patients with three-vessel disease and a resting radionuclide ejection fraction of more than 40%, a subgroup with higher risk could not be identified on the basis of exercise radionuclide response

  17. Measurement of left-to-right shunts by gated radionuclide angiography: concise communication

    International Nuclear Information System (INIS)

    Rigo, P.; Chevigne, M.

    1982-01-01

    Gated cardiac blood-pool scans allow comparison of left- and right-ventricular stroke volume. We have applied these measurements to the quantification of left-to-right shunts (QP/QS) in nine patients with atrial septal defects, one patients with partial anomalous pulmonary venous return, four patients with ventricular septal defects, and two patients with patent ductus arteriosus. None of these patients had combined lesions. QP/QS was measured as the right-ventricular (RV) stroke counts divided by the left-ventricular (LV) stroke counts and as the LV stroke counts divided by the RV stroke counts in patients with RV and LV diastolic volume overload respectively. All patients had also QP/QS measurements by oximetry and first-pass radionuclide angiography. The stroke-count measurements indicated the overloaded ventricle in all patients. QP/QS determined by equilibrium gated studies correlated well with those obtained by oximetry (r . 0.79). Reproducibility of the equilibrium measurements was good. We conclude that gated cardiac blood-pool scans can measure left-to-right shunts and can distinguish between shunts with RV and LV volume overload

  18. Computer assisted radionuclide angiography to confirm reversible ischemic cerebral dysfunction

    International Nuclear Information System (INIS)

    Buell, U.; Lanksch, W.; Tosch, U.; Kleinhans, E.; Steinhoff, H.

    1982-01-01

    Computer assisted radionuclide angiography (CARNA) was employed in patients with transient ischemic attack (TIA) or prolonged reversible ischemic neurologic deficit (PRIND) to establish the sensitivity of CARNA in detecting and quantifying changes of cerebral perfusion in such selected patients. Moreover, results of CARNA were compared with findings of cranial radiographic angiography (RGA) to obtain data on combined sensitivities of these methods. CARNA may be the preferred noninvasive procedure employed because it detects and quantifies the vascular supply disorder in patients with TIA and PRIND. If no computer assistance is used to evaluate cranial radionuclide angiography, results are considerable less accurate. Specifity of CARNA is 84.6%. If CARNA is negative (25.2% in TIA; 12.7% in PRIND), a further method must be employed to confirm the cranial vascular origin of the attack. This may be RGA in TIA and transmission computed axial tomography (T-CAT) T-CAT in PRIND. This diagnos - tic sequence lead to 92.4% true positive in TIA and to 93.2% true positives in PRIND

  19. Validation of attenuation-corrected equilibrium radionuclide angiographic determinations of right ventricular volume: comparison with cast-validated biplane cineventriculography

    International Nuclear Information System (INIS)

    Dell'Italia, L.J.; Starling, M.R.; Walsh, R.A.; Badke, F.R.; Lasher, J.C.; Blumhardt, R.

    1985-01-01

    To determine the accuracy of attenuation-corrected equilibrium radionuclide angiographic determinations of right ventricular volumes, the authors initially studied 14 postmortem human right ventricular casts by water displacement and biplane cineventriculography. Biplane cineventriculographic right ventricular cast volumes, calculated by a modification of Simpson's rule algorithm, correlated well with right ventricular cast volumes measured by water displacement (r = .97, y = 8 + 0.88x, SEE = 6 ml). Moreover, the mean volumes obtained by both methods were no different (73 +/- 28 vs 73 +/- 25 ml). Subsequently, they studied 16 patients by both biplane cineventriculography and equilibrium radionuclide angiography. The uncorrected radionuclide right ventricular volumes were calculated by normalizing background corrected end-diastolic and end-systolic counts from hand-drawn regions of interest obtained by phase analysis for cardiac cycles processed, frame rate, and blood sample counts. Attenuation correction was performed by a simple geometric method. The attenuation-corrected radionuclide right ventricular end-diastolic volumes correlated with the cineventriculographic end-diastolic volumes (r = .91, y = 3 + 0.92x, SEE = 27 ml). Similarly, the attenuation-corrected radionuclide right ventricular end-systolic volumes correlated with the cineventriculographic end-systolic volumes (r = .93, y = - 1 + 0.91x, SEE = 16 ml). Also, the mean attenuation-corrected radionuclide end-diastolic and end-systolic volumes were no different than the average cineventriculographic end-diastolic and end-systolic volumes (160 +/- 61 and 83 +/- 44 vs 170 +/- 61 and 86 +/- 43 ml, respectively)

  20. Global ejection fraction and phase analysis assessed by radionuclide angiography during exercise and after isoproterenol infusion

    International Nuclear Information System (INIS)

    Righetti, A.; Ratib, O.; Merier, G.; Widmann, T.; Donath, A.

    1983-01-01

    Radionuclide angiography obtained during and following Isoproterenol infusion is a new approach for detecting latent myocardial ischemia. It is very sensitive and could be considered as an alternative to conventional exercice radionuclide angiography. The data presented show that phase analysis assessment of regional systolic wall motion is a better indicator than global ejection fraction for quantifying left ventricular dysfunction

  1. Splenic radionuclide angiography in the portal hypertension assessment

    International Nuclear Information System (INIS)

    Artiko, V.; Kostic, K.; Perisic-Savic, M.; Janosevic, S.; Obradovic, V.

    2004-01-01

    The aim of this study is the presentation of the hepatic and splenic radionuclide angiograms (SRA) in various portal blood flow disturbances, as well as an analysis of the splenic arterio-venous ratio (SAVR) results, obtained as a slope ratio between inflow, arterial and the outflow, venous phases on the splenic TA curve. Splenic radionuclide angiography was performed after bolus injection of 740 MBq of 99m-Tc-pertechnetate, using ROTA scintillation camera (Siemens) and MicroDelta computer'. Four types of the SRA were established: a) very acute descendent slope (DS) in the controls; b) less acute DS in the patients with LC; c) horisontal venous phase caused by impaired outflow to the portal vein in LC with expressed portal hypertension, collateral circulation and LCEV; d) ascending outflow phase, characterizing the splenic and/or portal venous thrombosis. SAVR values were increased in liver cirrhosis (LC) with esophageal vahces (LCEV, n=10) (6.1 +/- 3.4) in comparison to the controls (n=10)(3.7 +/- 1.3)(U=25, p 0.05). However, in another two patients with LC and in 8 with LCEV it was not possible to access SAVR because of the appearance of the horisontal or rising venous phase on the splenic TA curve, instead of descendent. SRA and increased SAVR values reflect various blood flow alterations in the portal system and give additional data to the more accurate interpretation of the results obtained by hepatic radionuclide angiography. (authors)

  2. Use of first-pass radionuclide angiography for evaluating left-sided heart regurgitation

    International Nuclear Information System (INIS)

    Mantel, J.; Freidin, M.; Willens, H.; Rubenfire, M.; Bahl, R.; Ruskin, R.; Cascade, P.

    1986-01-01

    The first-pass radionuclide technique can be used to evaluate valvular regurgitation. Sixty-three patients were studied with cardiac catheterization and first-pass radionuclide angiography. The degree of regurgitation by cardiac catheterization was evaluated by using a ranking scale of 0-4, where 4 is severe regurgitation. The results were as follows: for nine patients, rank = 0, and percentage of regurgitation (mean +- SD) = 3.6 +- 5; for five patients, rank = 1 and percentage regurgitation = 15.8 +- 3; for 13 patients, rank = 2 and percentage regurgitation = 28.5 +- 14; for 16 patients, rank = 3 and percentage regurgitation = 41.5 +- 10; and for 19 patients, rank = 4 and percentage regurgitation 54.9 +- 13. A correlation coefficient of .90 between cardiac catheterization and the first-pass technique was calculated. The authors conclude that first-pass radionuclide angiography can quantitate valvular regurgitation and accurately differentiate between no, minimal, moderate, and severe valvular regurgitation

  3. Combined evaluation of first-pass radionuclide angiography and epuilibrium radionuclide ventriculography in the diagnosis of coronary artery disease. Pt. 1

    International Nuclear Information System (INIS)

    Knesewitsch, P.; Kleinhans, E.; Buell, U.

    1986-01-01

    The results of 203 patients who underwent first-pass radionuclide angiography (FP), as well as quantitative equilibrium radionuclide ventriculography (qERNV), were stored in a data base system and evaluated statistically. In patients with coronary artery disease (CAD) without previous myocardial infarction (MI), evaluation of global and regional ejection fraction (gEF, rEF) at rest revealed a poor sensitivity of 64% (Rest-qERNV) and 69% (Rest-FP), respectively. In patients with a history of one previous MI, the sensitivity of both methods was equivalent: FP 87% and qERNV 84%. In patients with several MIs, sensitivity was higher than 90%. Concerning localization of MI, remarkable differences between FP and qERNV were found. In posterior wall infarction, the FP sensitivity was 87% and qERNV only 67%, whereas in anterior wall infarction, the results were similar for both methods.: 93% (FP) and 96% (qERNV), respectively. Since 30 0 RAO camera position achieves the best visualization of the anterior and posterior wall, FP is superior to qERNV in the evaluation of posterior wall asynergies. In addition, qERNV often fails to discriminate anterior and posterior wall motion abnormalities. (orig.)

  4. Radionuclide angiography in graded carotoid stenosis. An experimental study with angiographic correlation

    International Nuclear Information System (INIS)

    Weissman, B.N.; Holman, B.L.; Rosenbaum, A.E.

    1975-01-01

    Radionuclide and contrast angiographies were performed in 10 dogs. In 6 dogs unilateral or bilateral (partial or total) carotid occlusions were produced by silk ligatures. Follow-up angiographies were carried out at intervals up to 6 months following surgery. Visual assessment of the radionuclide carotid angiogram was compared to quantitative analysis of the time-activity curves over these areas. Several parameters of these curves were reviewed. The ratio of the slopes was the most sensitive parameter of the assessment of carotid artery stenosis. The ratio of the slopes of the curves in normal dogs (mean 96 +- 5.2 S.D.) was significantly different from that in animals with stenosis greater than 80 percent (mean 67.3 +- 16.9 S.D.). (U.S.)

  5. Extrahepatic portal hypertension in childhood. Portographic findings and evaluation of hepatic blood flow by computerized radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Takehara, Hiroo; Komi, Nobuhiko; Goh, Masahiro; Yoshida, Sadahiro; Kameoka, Kazuhiro; Hino, Masao; Sui, Osamu

    1986-05-01

    Four pediatric patients with extrahepatic portal hypertension had undergone portography and computerized radionuclide angiography in order to examine shape of portal system and to evaluate hepatic blood flow before and aftersurgical treatment. In all patients, cavernous transformation of portal system was demonstrated by portography, and in one of them spontaneous splenorenal shunt occurred. In 3 of them, who underwent esophageal transsection combined with paraesophagogastric devascularization and splenectomy, so-called direct operation, increase of portal blood flow was revealed by computerized radionuclide angiography. It is suggested that direct operation increasing portal blood flow after surgery is effective in treating extrahepatic portal hypertension in childhood.

  6. Measurement of Finger Blood Flow in Raynauds Phenomenon by Radionuclide Angiography

    International Nuclear Information System (INIS)

    Lim, Sang Moo; Chung, June Key; Lee, Myung Chul; Kim, Sang Joon; Choi, Sung Jae; Koh, Chang Soon

    1987-01-01

    In Raynauds phenomenon, the authors measured finger blood flow after ice water exposure by analyzing the time activity curve of radionuclide angiography on both hands. The results were as follows: 1) The digital blood flow did not decrease after ice water exposure in normal subjects. 2) In the patients with Raynauds phenomenon, there were two groups: the one had decreased digital blood flow after cold exposure, and the other had paradoxically increased digital blood flow after cold exposure. 3) There was no difference in the digital blood flow of hand in room temperature between the normal and the patients with reduced digital blood flow after cold exposure, but the digital blood flow of the hand in room temperature was markedly reduced in the patients with paradoxically increased flow after cold exposure. 4) In the static image the difference was not significant in comparison with the dynamic study, because it represents pooling of the blood in the vein rather than flow. 5) After the treatment with nifedipine, the digital blood flow increased. In conclusion, the radionuclide angiography was useful in measuring the digital blood flow in Raynauds phenomenon, and further studies with various drugs is expected.

  7. Analysis of hepatoportal hemodynamics by hepatic radionuclide angiography on patients with portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Mitarai, Y; Yoshida, T; Yoshimura, T; Nagamine, K; Kanashima, R; Kobayashi, M; Nakashima, A; Kato, Y; Maeda, H

    1987-04-01

    Hepatoportal circulation was measured using radionuclide angiography with /sup 99m/Tc-fibrinogen in 40 patients with or without portal hypertension ; 20 cirrhotics with esophageal varices(LC with varices), 5 cirrhotics without esophageal varices(LC without varices), 5 patients with idiopathic portal hypertension(IPH) and 10 controls. In 8 cases among LC with varices, the hemodynamics was determined before and after left gastric vena caval shunt(LGCS). The radioactivity count and PA ratio(blood flow proportion of the portal vein to the hepatic artery) at the hepatic hilus were lower in the patients with liver cirrhosis(LC with and without varices) than those of the cases without liver cirrhosis(IPH and control). The comparison of hemodynamics before and during 6 weeks after LGCS demonstrated the radioactivity count well-preserved but on the contrary the PA ratio reduced at the hepatic hilus after surgery. The present results could indicate that the total hepatic inflow was maintained following LGCS, by compensatory increase of hepatic arterial flow in response to reduced portal flow. The implication of hepatic radionuclide angiography is discussed on patients with portal hypertension.

  8. Analysis of hepatoportal hemodynamics by hepatic radionuclide angiography on patients with portal hypertension

    International Nuclear Information System (INIS)

    Mitarai, Yoshinobu; Yoshida, Takanori; Yoshimura, Takahisa; Nagamine, Kenji; Kanashima, Ryoichi; Kobayashi, Michio; Nakashima, Akihisa; Kato, Yukio; Maeda, Hirofumi

    1987-01-01

    Hepatoportal circulation was measured using radionuclide angiography with 99m Tc-fibrinogen in 40 patients with or without portal hypertension ; 20 cirrhotics with esophageal varices(LC with varices), 5 cirrhotics without esophageal varices(LC without varices), 5 patients with idiopathic portal hypertension(IPH) and 10 controls. In 8 cases among LC with varices, the hemodynamics was determined before and after left gastric vena caval shunt(LGCS). The radioactivity count and PA ratio(blood flow proportion of the portal vein to the hepatic artery) at the hepatic hilus were lower in the patients with liver cirrhosis(LC with and without varices) than those of the cases without liver cirrhosis(IPH and control). The comparison of hemodynamics before and during 6 weeks after LGCS demonstrated the radioactivity count well-preserved but on the contrary the PA ratio reduced at the hepatic hilus after surgery. The present results could indicate that the total hepatic inflow was maintained following LGCS, by compensatory increase of hepatic arterial flow in response to reduced portal flow. The implication of hepatic radionuclide angiography is discussed on patients with portal hypertension. (author)

  9. Improved left ventricular function after growth hormone replacement in patients with hypopituitarism: assessment with radionuclide angiography

    International Nuclear Information System (INIS)

    Cuocolo, A.; Nicolai, E.; Colao, A.; Longobardi, S.; Cardei, S.; Fazio, S.; Merola, B.; Lombardi, G.; Sacca, L.; Salvatore, M.

    1996-01-01

    Prolonged growth hormone deficiency (GHD) leads to marked cardiac dysfunction; however, whether reversal of this abnormality may be achieved after specific replacement therapy has not yet been completely clarified. Fourteen patients with childhood-onset GHD (nine men and five women, mean age 27±4 years) and 12 normal control subjects underwent equilibrium radionuclide angiography under control conditions at rest. Patients with GHD were also studied 6 months after recombinant human (rh) GH treatment (0.05 IU/kg per day). Normal control subjects and patients with GHD did not differ with respect to age, gender and heart rate. In contrast, left ventricular ejection fraction (53%±9% vs 66%±6%, P 2 , P 2 , P 2 , P 2 , P <0.01) was observed in GHD patients. In conclusion, prolonged lack of GH leads to impaired left ventricular function at rest. Reversal of this abnormality may be observed after 6 months of specific replacement therapy in patients with childhood-onset GHD. (orig.). With 4 figs., 1 tab

  10. Interventricular delay measurement using equilibrium radionuclide angiography before resynchronization therapy should be performed outside the area of segmental wall motion abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Courtehoux, Maxime [Service EFMP CHU Trousseau, Chambray les Tours (France); Zannad, Noura; Fauchier, Laurent; Babuty, Dominique [Service Cardiologie B CHU Trousseau, Tours (France); Eder, Veronique [Service EFMP CHU Trousseau, Chambray les Tours (France); EA3852 University Francois Rabelais, Tours (France)

    2011-02-15

    The aim of this study was to demonstrate that only mechanical dyssynchrony outside the area of segmental wall motion abnormalities (WMA) can be reduced by cardiac resynchronization therapy (CRT). Included in the study were 28 consecutive patients with nonischaemic cardiomyopathy selected for CRT. Equilibrium radionuclide angiography (ERNA) was carried out before and after implantation of a multisite pacemaker. Patients were separated into two groups depending on the presence or absence of segmental WMA. A reduction in QRS duration was observed in all patients after CRT. The interventricular delay (IVD) decreased significantly after CRT only in patients without WMA (homogeneous contraction, HG group; IVD 44 {+-} 11.4 vs. 17 {+-} 3.1 , p = 0.04). In contrast, no significant decrease was observed in patients with WMA (WMA group; IVD 51 {+-} 6 vs. 38 {+-} 6 , p NS). However, when dyssynchrony was considered outside the WMA area, a significant reduction in IVD was obtained, in the same range as in the HG group (IVD 32 {+-} 3 vs. 19 {+-} 3 , p = 0.04). In 9 of 15 patients (60%) with a reduction in IVD after CRT, the left ventricle ejection fraction (LVEF) increased by about +10%. In contrast, in 13 of 13 patients (100%) with no reduction in IVD, no modification of LVEF was obtained. In the presence of segmental WMA without significant delays outside the WMA area, no reduction in IVD was observed and LVEF did not increase (IVD 34 {+-} 5 before CRT vs. 37 {+-} 7 after CRT; LVEF 19 {+-} 4% before CRT vs. 22 {+-} 3% after CRT, p NS). ERNA can be used to predict good mechanical resynchronization (decrease in IVD) in patients after pacing. IVD has to be determined excluding the area of WMA in order to select patients who will show an increase in their left ventricle function after CRT. (orig.)

  11. Follicular thyroid carcinoma masquerading as subacute thyroiditis diagnosis using ultrasonography and radionuclide thyroid angiography

    International Nuclear Information System (INIS)

    Prakash, R.; Jayaram, G.

    1991-01-01

    The rare presentation of a follicular thyroid carcinoma mimicking the clinical and radionuclide features of subacute thyroiditis is described. Granulomatous thyroiditis was initially suspected on the clinical basis. Repeat fine needle aspiration cytology was suggestive of acinar proliferation with hyperfunction. Ultrasonography revealed a solid nodule with a peripheral sonolucent halo. Radionuclide angiography showed intense arterial flow of Tc-99m pertechnetate through the right lobe thyroid enlargement suggestive of malignant thyroid pathology. Surgical excision and histopathological examination revealed a follicular carcinoma involving the right lobe. 31 refs., 4 figs

  12. Simultaneous maximal exercise radionuclide angiography and thallium stress perfusion imaging

    International Nuclear Information System (INIS)

    Narahara, K.A.; Mena, I.; Maublant, J.C.; Brizendine, M.; Criley, J.M.

    1984-01-01

    Gold-195m is a new ultra-short-lived radionuclide that can be used for cardiac studies. Accurate, reproducible ejection fraction and ventricular wall motion studies can be obtained from first-transit angiography using commercially available imaging and image-processing equipment. The short half-life of gold-195m (30.5 seconds) makes simultaneous dual isotope imaging possible and substantially reduces the radiation exposure from the isotope angiography. The feasibility and possible benefits of performing dual radionuclide studies were evaluated during a single exercise stress test in 24 subjects with known coronary artery disease (CAD) and in 20 normal volunteers. High-quality first-transit angiograms were obtained in all subjects. An 83% sensitivity and 95% specificity for detecting CAD with thallium-201 imaging was noted in this investigation, suggesting that its diagnostic accuracy was not altered by simultaneous dual isotone imaging. When segmental left ventricular (LV) wall motion was compared with thallium-201 perfusion imaging, divergent results were noted in 15 of 44 subjects. An analysis of the ejection fraction (EF) results at rest and stress provided additional information that could be useful in assessing the clinical significance of such differences in segmental wall motion and perfusion. Simultaneous dual isotope imaging appears to be appropriate for situations in which both LV perfusion and function require evaluation. The use of gold-195m allows such information to be obtained from a single exercise test and can thereby reduce the cost and time required for noninvasive evaluations of patients for CAD

  13. Evaluation of Right Ventricular Function with Radionuclide Cardiac Angiography - Right Ventricular Ejection Fraction in Chronic Obstructive Lung Disease

    International Nuclear Information System (INIS)

    Sohn, In; Shin, Sung Hae; Chung, June Key; Lee, Myung Chul; Cho, Bo Youn; Lee, Young Woo; Han, Yong Cheol; Koh, Chang Soon

    1982-01-01

    To evaluate the usefulness of radionuclide cardiac angiography in the assessment of the right ventricular function, we measured right ventricular ejection fraction (RVEF) using single pass method. In 12 normal persons, RVEF averaged 52.7±5.9% (mean±S.D.). In 25 patients with chronic obstructive lung disease, RVEF was 37.2±10.6% and significantly lower than that of normal person (p<0.01). All 10 patients with right ventricular failure had abnormal RVEF, which was significantly lower than that of 14 persons without right ventricular failure (27.6±5.7%, 43.9±8.5%, respectively, p<0.01). It concluded that RVEF measured by single pass radionuclide cardiac angiography was a useful, noninvasive method to assess right ventricular function.

  14. Angiography and the gastrointestinal bleeder

    International Nuclear Information System (INIS)

    Baum, S.

    1982-01-01

    The role of angiography in the diagnosis and treatment of gastrointestinal hemorrhage is discussed. Three categories of gastrointestinal bleeding are considered: upper gastrointestinal bleeding due to gastroesophageal varices, upper gastrointestinal bleeding of arterial or capillary origin, and lower gastrointestinal bleeding. The advantages and disadvantages of angiography are compared with those of radionuclide scanning and endoscopy or colonoscopy. It is anticipated that, as radionuclide scans are more widely employed, angiography will eventually be performed only in those patients with positive scans

  15. Left ventricular diastolic performance at rest in patients with angina and normal systolic function - assessment by equilibrium radionuclide angiography

    International Nuclear Information System (INIS)

    Maini, C.L.; Bonetti, M.G.; Valle, G.; Antonelli Incalzi, R.; Montenero, A.S.

    1985-01-01

    The aim of the study was to correlate diastolic function, as evaluated by peak filling rate (PFR) and relative time (TPFR), with the severity of ischemic heart disease, as evaluated by exercise electrocardiography. Accordingly, 83 ischemic patients with effort angina, but normal ejection function at rest and normal left ventricular size, were studied by equilibrium radionuclide angiocardiography within two weeks from the exercise ECG. Diastolic dysfunction, as determined from PFR and, to a lesser extent, from TPFR, is common in patients with ischemic heart disease and normal systolic function. The prevalence and severity of such dysfunction is related more to the severity of the ischemia, as evaluated by the exercise ECG, than to the presence of an old myocardial infarction. Such findings are consistent with the hypothesis that PFR reflects mainly the early diastolic active uncoupling process. (orig.) [de

  16. Pre-chemotherapy values for left and right ventricular volumes and ejection fraction by gated tomographic radionuclide angiography using a cadmium-zinc-telluride detector gamma camera

    DEFF Research Database (Denmark)

    Haarmark, Christian; Haase, Christine; Jensen, Maria Maj

    2016-01-01

    age and both left and right ventricular volumes in women (r = -0.4, P right end systolic ventricular volume in men (r = -0.3, P = .001). CONCLUSION: A set of reference values for cardiac evaluation prior to chemotherapy in cancer patients without other known cardiopulmonary......BACKGROUND: Estimation of left ventricular ejection fraction (LVEF) using equilibrium radionuclide angiography is an established method for assessment of left ventricular function. The purpose of this study was to establish normative data on left and right ventricular volumes and ejection fraction......, using cadmium-zinc-telluride SPECT camera. METHODS AND RESULTS: From routine assessments of left ventricular function in 1172 patients, we included 463 subjects (194 men and 269 women) without diabetes, previous potentially cardiotoxic chemotherapy, known cardiovascular or pulmonary disease. The lower...

  17. Nuclear cardiology. I - Radionuclide angiographic assessment of left ventricular contraction: uses, limitations and future directions. II - The role of myocardial perfusion imaging using thallium-201 in diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Bodenheimer, M.M.; Banka, V.S.; Helfant, R.H.; Pennsylvania, University, Philadelphia, PA)

    1980-01-01

    The current status of radionuclide angiography is reviewed. First pass and gated equilibrium methods for determining left ventricular contraction are compared. Some clinical applications of radionuclide angiography are then examined, including the detection of discrete versus diffuse asynergy and the assessment of myocardial infarction. The second part of this work reviews the uses and limitations of thallium-201 perfusion imaging in the diagnosis of the acute and chronic manifestations of coronary heart disease. Theoretical and technical considerations of thallium-201 imaging are reviewed along with the clinical implications of the technique

  18. Testicular radionuclide angiography and sttatic imaging: anatomy, scintigraphic interpretation, and clinical indications

    International Nuclear Information System (INIS)

    Holder, L.E.; Martire, J.R.; Holmes, E.R. III.; Wagner, H.N. Jr.

    1977-01-01

    Radionuclide testicular angiography and static imaging is an easy, rapidly performed study. Its usefulness in separating acute testicular torsion from acute epididymitis has been confirmed. Increased angiographic perfusion with definition of the testicular and deferential arteries in the spermatic cord and the pudendal artery posteriorly is equated with inflammation. Intense increased vascularity on the blood pool image is seen in abscess and acute inflammation, while cases of tumor and trauma have mild increases. Acute or missed testicular torsion, uncomplicated hydroceles, and spermatoceles show absent vascularity. On the static images, decreased activity is characteristic of the shape and location of the avascular structure. Technical factors are stressed

  19. Normal left ventricular emptying in coronary artery disease at rest: analysis by radiographic and equilibrium radionuclide ventriculography

    International Nuclear Information System (INIS)

    Denenberg, B.S.; Makler, P.T.; Bove, A.A.; Spann, J.F.

    1981-01-01

    The volume ejected early in systole has been proposed as an indicator of abnormal left ventricular function that is present at rest in patients with coronary artery disease with a normal ejection fraction and normal wall motion. The volume ejected in systole was examined by calculating the percent change in ventricular volume using both computer-assisted analysis of biplane radiographic ventriculograms at 60 frames/s and equilibrium gated radionuclide ventriculograms. Ventricular emptying was examined with radiographic ventriculography in 33 normal patients and 23 patients with coronary artery disease and normal ejection fraction. Eight normal subjects and six patients with coronary artery disease had both radiographic ventriculography and equilibrium gated radionuclide ventriculography. In all patients, there was excellent correlation between the radiographic and radionuclide ventricular emptying curves (r . 0.971). There were no difference in the ventricular emptying curves of normal subjects and patients with coronary artery disease whether volumes were measured by radiographic or equilibrium gated radionuclide ventriculography. It is concluded that the resting ventricular emptying curves are identical in normal subjects and patients with coronary artery disease who have a normal ejection fraction and normal wall motion

  20. Evaluation of segmental left ventricular wall motion by equilibrium gated radionuclide ventriculography.

    Science.gov (United States)

    Van Nostrand, D; Janowitz, W R; Holmes, D R; Cohen, H A

    1979-01-01

    The ability of equilibrium gated radionuclide ventriculography to detect segmental left ventricular (LV) wall motion abnormalities was determined in 26 patients undergoing cardiac catheterization. Multiple gated studies obtained in 30 degrees right anterior oblique and 45 degrees left anterior oblique projections, played back in a movie format, were compared to the corresponding LV ventriculograms. The LV wall in the two projections was divided into eight segments. Each segment was graded as normal, hypokinetic, akinetic, dyskinetic, or indeterminate. Thirteen percent of the segments in the gated images were indeterminate; 24 out of 27 of these were proximal or distal inferior wall segments. There was exact agreement in 86% of the remaining segments. The sensitivity of the radionuclide technique for detecting normal versus any abnormal wall motion was 71%, with a specificity of 99%. Equilibrium gated ventriculography is an excellent noninvasive technique for evaluating segmental LV wall motion. It is least reliable in assessing the proximal inferior wall and interventricular septum.

  1. Diagnosis and screening of small hepatocellular carcinomas. Comparison of radionuclide imaging, ultrasound, computed tomography, hepatic angiography, and alpha 1-fetoprotein assay

    International Nuclear Information System (INIS)

    Takashima, T.; Matsui, O.; Suzuki, M.; Ida, M.

    1982-01-01

    Twenty-nine small (less than 5 cm) hepatocellular carcinomas in 18 patients were examined by radionuclide imaging (RN), ultrasound (US), computed tomography (CT), hepatic angiography, and serum alpha 1-fetoprotein (AFP) assay. Sensitivity was 39% with RN, 50% with US, 56% with CT, and 94% with angiography, including infusion hepatic angiography (IHA). Lesions larger than 3 cm could be detected by all of these methods; those between 2 and 3 cm were generally shown by US and CT but not RN. IHA was essential for diagnosis of lesions less than 2 cm, which were otherwise difficult or impossible to detect except with angiography. As a screening method, AFP was best, followed by US and CT. The authors recommend using AFP and US to minimize expense and radiation exposure. In questionable cases, IHA should be performed

  2. Measurement of absolute left ventricular volume by radionuclide angiography: a technical review

    International Nuclear Information System (INIS)

    Al-Khawaja, I.M.; Lahiri, Avijit; Raftery, E.B.; Medical Research Council, Harrow

    1988-01-01

    Absolute left ventricular volumes have important clinical implications in the evaluation of cardiac performance. Several invasive and noninvasive techniques have been reported, none of which can be considered ideal for this purpose. Contrast angiography, echocardiography and radionuclide ventriculography are open to criticism. Different radioisotopic approaches are described with emphasis on the importance of accurate separation of left ventricular activity, the selection of background activity, and the correction for photon attenuation by body tissues. Improper use of statistics and validation techniques have obscured the value of these techniques. In the absence of a 'gold standard' there should be a 'radioisotopic' left ventricular volume with established independent characteristics, repeatability and reproducibility by which new approaches can be judged. (author)

  3. A Case of Pulmonary Artery Aneurysm Associated with Patent Ductus Arteriosus : Detection by Radionuclide Cardiac Angiography

    International Nuclear Information System (INIS)

    Sohn, I.; Lee, M. C.; Cho, B. Y.; Koh, C. S.; Yoon, Y. S.; Hong, C. Y.; Rho, J. R.; Youn, K. M.; Han, M. C.

    1981-01-01

    A Case of main pulmonary artery aneurysm in a 9-year-old boy with patent ductus arteriosus is presented. In this case presented with a huge mass density on the chest X-ray, radionuclide cardiac angiography showed a vascular lesion, which was confirmed as an aneurysm of the main pulmonary artery at roentgenologic angiogram. The aneurysm appeared following an episode of bacterial endocarditis and pulmonary hypertension. A successful aneurysmectomy with multiple ligation of ductus arteriosus was performed.

  4. A Case of Pulmonary Artery Aneurysm Associated with Patent Ductus Arteriosus : Detection by Radionuclide Cardiac Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, I; Lee, M C; Cho, B Y; Koh, C S; Yoon, Y S; Hong, C Y; Rho, J R; Youn, K M; Han, M C [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1981-09-15

    A Case of main pulmonary artery aneurysm in a 9-year-old boy with patent ductus arteriosus is presented. In this case presented with a huge mass density on the chest X-ray, radionuclide cardiac angiography showed a vascular lesion, which was confirmed as an aneurysm of the main pulmonary artery at roentgenologic angiogram. The aneurysm appeared following an episode of bacterial endocarditis and pulmonary hypertension. A successful aneurysmectomy with multiple ligation of ductus arteriosus was performed.

  5. Radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Heidenreich, P; Klotz, E

    1983-12-27

    RNA of common and internal carotid arteries as well as main cerebral arteries is the first component of cerebral serial scintigraphy. It should be the first diagnostic step in suspected cerebrovascular disease. In contrast to computed tomography RNA gives valuable information about cerebrovascular processes without morphological defects. RNA is superior of Doppler sonography in the evaluation of intracranial vascular disease. The simple and non-invasive RNA of the kidneys should be performed after renal transplantation (i.e. differential diagnosis of acute rejection and acute tubular necrosis), in suspected renal artery stenosis, renal infarction or in arterio-venous malformation of the kidneys. RNA is valuable in suspected occlusion of the abdominal aorta (infra- or suprarenal), aortic aneurysm or in stenosis of arteries in the pelvis or thighs. Postoperative controls can be carried out as often as desired. However, it cannot replace contrast angiography if vascular reconstruction is planned.

  6. Assessment of poststress left ventricular ejection fraction by gated SPECT: comparison with equilibrium radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Acampa, Wanda; Liuzzi, Raffaele; De Luca, Serena; Capasso, Enza; Luongo, Luca; Cuocolo, Alberto; Caprio, Maria Grazia; Nicolai, Emanuele; Petretta, Mario

    2010-01-01

    We compared left ventricular (LV) ejection fraction obtained by gated SPECT with that obtained by equilibrium radionuclide angiocardiography in a large cohort of patients. Within 1 week, 514 subjects with suspected or known coronary artery disease underwent same-day stress-rest 99m Tc-sestamibi gated SPECT and radionuclide angiocardiography. For both studies, data were acquired 30 min after completion of exercise and after 3 h rest. In the overall study population, a good correlation between ejection fraction measured by gated SPECT and by radionuclide angiocardiography was observed at rest (r=0.82, p<0.0001) and after stress (r=0.83, p<0.0001). In Bland-Altman analysis, the mean differences in ejection fraction (radionuclide angiocardiography minus gated SPECT) were -0.6% at rest and 1.7% after stress. In subjects with normal perfusion (n=362), a good correlation between ejection fraction measured by gated SPECT and by radionuclide angiocardiography was observed at rest (r=0.72, p<0.0001) and after stress (r=0.70, p<0.0001) and the mean differences in ejection fraction were -0.9% at rest and 1.4% after stress. Also in patients with abnormal perfusion (n=152), a good correlation between the two techniques was observed both at rest (r=0.89, p<0.0001) and after stress (r=0.90, p<0.0001) and the mean differences in ejection fraction were 0.1% at rest and 2.5% after stress. In a large study population, a good agreement was observed in the evaluation of LV ejection fraction between gated SPECT and radionuclide angiocardiography. However, in patients with perfusion abnormalities, a slight underestimation in poststress LV ejection fraction was observed using gated SPECT as compared to equilibrium radionuclide angiocardiography. (orig.)

  7. Right ventricular functional analysis utilizing first pass radionuclide angiography for pre-operative ventricular assist device planning: a multi-modality comparison.

    Science.gov (United States)

    Avery, Ryan; Day, Kevin; Jokerst, Clinton; Kazui, Toshinobu; Krupinski, Elizabeth; Khalpey, Zain

    2017-10-10

    Advanced heart failure treated with a left ventricular assist device is associated with a higher risk of right heart failure. Many advanced heart failures patients are treated with an ICD, a relative contraindication to MRI, prior to assist device placement. Given this limitation, left and right ventricular function for patients with an ICD is calculated using radionuclide angiography utilizing planar multigated acquisition (MUGA) and first pass radionuclide angiography (FPRNA), respectively. Given the availability of MRI protocols that can accommodate patients with ICDs, we have correlated the findings of ventricular functional analysis using radionuclide angiography to cardiac MRI, the reference standard for ventricle function calculation, to directly correlate calculated ejection fractions between these modalities, and to also assess agreement between available echocardiographic and hemodynamic parameters of right ventricular function. A retrospective review from January 2012 through May 2014 was performed to identify advanced heart failure patients who underwent both cardiac MRI and radionuclide angiography for ventricular functional analysis. Nine heart failure patients (8 men, 1 woman; mean age of 57.0 years) were identified. The average time between the cardiac MRI and radionuclide angiography exams was 38.9 days (range: 1 - 119 days). All patients undergoing cardiac MRI were scanned using an institutionally approved protocol for ICD with no device-related complications identified. A retrospective chart review of each patient for cardiomyopathy diagnosis, clinical follow-up, and echocardiogram and right heart catheterization performed during evaluation was also performed. The 9 patients demonstrated a mean left ventricular ejection fraction (LVEF) using cardiac MRI of 20.7% (12 - 40%). Mean LVEF using MUGA was 22.6% (12 - 49%). The mean right ventricular ejection fraction (RVEF) utilizing cardiac MRI was 28.3% (16 - 43%), and the mean RVEF calculated by

  8. Equilibrium-phase MR angiography: Comparison of unspecific extracellular and protein-binding gadolinium-based contrast media with respect to image quality.

    Science.gov (United States)

    Erb-Eigner, Katharina; Taupitz, Matthias; Asbach, Patrick

    2016-01-01

    The purpose of this study was to compare contrast and image quality of whole-body equilibrium-phase high-spatial-resolution MR angiography using a non-protein-binding unspecific extracellular gadolinium-based contrast medium with that of two contrast media with different protein-binding properties. 45 patients were examined using either 15 mL of gadobutrol (non-protein-binding, n = 15), 32 mL of gadobenate dimeglumine (weakly protein binding, n = 15) or 11 mL gadofosveset trisodium (protein binding, n = 15) followed by equilibrium-phase high-spatial-resolution MR-angiography of four consecutive anatomic regions. The time elapsed between the contrast injection and the beginning of the equilibrium-phase image acquisition in the respective region was measured and was up to 21 min. Signal intensity was measured in two vessels per region and in muscle tissue. Relative contrast (RC) values were calculated. Vessel contrast, artifacts and image quality were rated by two radiologists in consensus on a five-point scale. Compared with gadobutrol, gadofosveset trisodium revealed significantly higher RC values only when acquired later than 15 min after bolus injection. Otherwise, no significant differences between the three contrast media were found regarding vascular contrast and image quality. Equilibrium-phase high-spatial-resolution MR-angiography using a weakly protein-binding or even non-protein-binding contrast medium is equivalent to using a stronger protein-binding contrast medium when image acquisition is within the first 15 min after contrast injection, and allows depiction of the vasculature with high contrast and image quality. The protein-binding contrast medium was superior for imaging only later than 15 min after contrast medium injection. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Right ventricular ejection fraction - comparison of various angiographic and radionuclide approaches

    International Nuclear Information System (INIS)

    Schicha, H.; Tebbe, U.; Voth, E.; Sciagra, R.; Schultz, W.; Neuhaus, G.; Goettingen Univ.

    1987-01-01

    In 21 patients with various heart diseases RVEF was measured angiographically and by radionuclide ventriculography. Using biplane angiocardiography evaluation was performed by 7 different methods (Simpson's rule, Dogde, Arcilla, Ferlinz, Duebel). Using equilibrium RNV, evaluation was performed by 9 modifications of analysis. Problems were evident to separate the right atrium from the ventricle and to define the site of the pulmonary valve. The results show that when using the various methods of angiography considerable variations of the absolute volumes occur, but least so with RVEF. When using RNV with one single enddiastolic ROI, the RVEF was much too low. By means of the enddiastolic/endsystolic Double-ROI-method a good agreement with angiography was found, with correlation coefficients up to r=0.85. There was only a minor effect of background correction. (orig.) [de

  10. A report on intercomparison studies of computer programs which respectively model: i) radionuclide migration ii) equilibrium chemistry of groundwater

    International Nuclear Information System (INIS)

    Broyd, T.W.; McD Grant, M.; Cross, J.E.

    1985-01-01

    This report describes two intercomparison studies of computer programs which respectively model: i) radionuclide migration ii) equilibrium chemistry of groundwaters. These studies have been performed by running a series of test cases with each program and comparing the various results obtained. The work forms a part of the CEC MIRAGE project (MIgration of RAdionuclides in the GEosphere) and has been jointly funded by the CEC and the United Kingdom Department of the Environment. Presentations of the material contained herein were given at plenary meetings of the MIRAGE project in Brussels in March, 1984 (migration) and March, 1985 (equilibrium chemistry) respectively

  11. Regional ejection fraction: a quantitative radionuclide index of regional left ventricular performance

    International Nuclear Information System (INIS)

    Maddox, D.E.; Wynne, J.; Uren, R.; Parker, J.A.; Idoine, J.; Siegel, L.C.; Neill, J.M.; Cohn, P.F.; Holman, B.L.

    1979-01-01

    Left ventricular regional ejection fractions were derived from background-corrected, time-activity curves in 43 patients assessed by both gated equilibrium radionuclide angiocardiography and left ventricular contrast angiography. From a single, modified left anterior oblique projection, the regional change in background corrected counts was determined in each of three anatomic regions. The normal range for regional radionuclide ejection fraction was determined in 10 patients with normal contrast ventriculograms and without obstructive coronary artery disease at coronary arteriography. Regional ejection fraction was compared with percent segmental axis shortening and extent of akinetic segments in corresponding regions of the contrast ventriculogram. Radionuclide and roentgenographic methods were in agreement as to the presence or absence of abnormal wall motion in 83 of 99 left ventricular regions (84%) in 33 patients evaluated prospectively. Comparison of regional ejection fraction demonstrated significant differences between regions with roentgenographically determined normokinesis hypokinesis, and akinesis. We conclude that the left ventricular regional ejection fraction provides a reliable quantitative assessment of regional left ventricular performance

  12. Equilibrium concentration of radionuclides in cement/groundwater/carbon steel system

    International Nuclear Information System (INIS)

    Keum, D. K.; Cho, W. J.; Hahn, P. S.

    1997-01-01

    Equilibrium concentration of major elements in an underground repository with a capacity of 100,000 drums have been simulated using the geochemical computer code (EQMOD). The simulation has been carried out at the conditions of pH 12 to 13.5, and Eh 520 and -520 mV. Solubilities of magnesium and calcium decrease with the increase of pH. The solubility of iron increases with pH at Eh -520 mV of reducing environment, while it almost entirely exists as the precipitate of Fe(OH) 3 (s) at Eh 520 mV of oxidizing environment. All of cobalt and nickel are predicted to be dissolved in the liquid phase regardless of pH since the solubility limit is greater than the total concentration. In the case of cesium and strontium, all forms of both ions are present in the liquid phase because they have negligible sorption capacity on cement and large solubility under disposal atmosphere. And thus the total concentration determines the equilibrium concentration. Adsorbed amounts of iodide and carbonate are dependent on adsorption capacity and adsorption equilibrium constant. Especially, the calcite turns out to be a solubility-limiting phase on the carbonate system. In order to validate the model, the equilibrium concentrations measured for a number of systems which consist of iron, cement, synthetic groundwater and radionuclides are compared with those predicted by the model. The concentrations between the model and the experiment of nonadsorptive elements - cesium, strontium, cobalt, nickel and iron, are well agreed. It indicates that the assumptions and the thermodynamic data in this work are valid. Using the adsorption equilibrium constant as a free parameter, the experimental data of iodide and carbonate have been fitted to the model. The model is in a good agreement with the experimental data of the iodide system. (author)

  13. Noninvasive quantitative assessment of cerebral blood flow (CBF) using Tc-99m ECD SPECT with adjunctive radionuclide angiography in ischemic stroke

    International Nuclear Information System (INIS)

    Yim, Jun Sung; Choi, Yun Young; Kim, Seung Hyun; Kim, Myung Ho; Cho, Suk Shin

    1999-01-01

    Quantitative CBF measurements are essential for diagnosing ischemic lesion, evaluating the therapeutic effects and predicting the prognosis of cerebral ischemia. Even though several methods have been introduced, these techniques are too cumbersome and invasive to be applied to routine studies. In this study, a non-invasive simple method for the quantitative angiography. Fifteen normal controls and 27 patients with unilateral carotid ischemic stoke were selected. Brain perfusion index (BPI) of each hemisphere was measured in each subject by acquisition of serial radionuclide angiography after injection of 20mCi of Tc-99m ECD. With Lassen's correction algorithm of curve-linear relationship between the brain activity and blood flow, rCBF on transaxial SPECT slice corresponding with MRI lesion sites (ischemic core, border zone and contralateral mirror locus) were calculated. BPI values for normal controls showed a significant negative correlation with advantage age (r=-0.64, p=0.021) and hemisphric BPI were 11.02±1.6 and 7.8±1.4 for normal controls and patient, respectively. Significant differences were observed between two groups (p=0.0012). rCBF obtained from core zone (12±2.5 ml/100/min), boneder zone (29.2±8.1) and contralateral mirror locus (52.1±15.1) were clearly defined in each subject of patient group. Measurement of BPI and rCBF using Tc-99m ECD SPECT with adjunctive radionuclide angiography could be an useful, simple and non-invasive method in evaluation of the cerebral flood in the ischemic stroke

  14. Validation of rest and exercise radionuclide angiography in patients with aortic regurgitation

    International Nuclear Information System (INIS)

    Gosiewska-Marcinkowska, E.; Rawczynska-Englert, I.; Szumilak, B.; Konieczna, S.; Rozycka-Chrzanowska, B.

    1992-01-01

    The aim of the study was to evaluate the significance of rest and stress test using radionuclide angiography (RA) in assessment of left ventricular (LV) function in the patients with aortic regurgitation (AR). In 32 patients we analyzed pre and 12 months after aortic valve replacement (AVR) the clinical data (including LV cavity dimension, LV hypertrophy, relative heart volume - RHV, the value of diastolic pressure) and the RA at rest and during supine stress test. We compared the clinical data with eject fraction (EF) and rest (EFr), at exercise (EFex) and ΔEF=EFex-EFr. Results show good correlation between clinical data and EF. Conclusions: 1) exercise RA is an useful method of estimation of LV function and after AVR; 2) early evaluation of the reserve of the LV allows to establish the appropriate time for AVR even before the signs of insufficiency of the LV are revealed. (author). 8 refs, 2 tabs

  15. Exercise intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Yiannikas, J.

    1986-01-01

    Attempts to use exercise ventriculography have been made, not only to give diagnostic and perhaps even prognostic information in patients with coronary artery disease, but also in patients with valvular heart disease both before and after surgical intervention. Clearly an accurate method of assessing ventricular function under conditions of stress in various cardiac diseases would provide important information that would help in patient management. Exercise ventriculography using gated blood pool equilibrium technetium studies are widely used, but are limited by spatial resolution and by the foreshortening affects of visualizing the left ventricular chamber in the left anterior oblique view. First pass radionuclide studies have the added advantage of being able to visualize the ventricular chamber in the anterior or even the right anterior oblique view, but are even more limited by their spatial resolution problems. Several investigations have shown that digital subtraction angiography produces left ventricular images with a spatial resolution almost identical to that of conventional contrast ventriculography, but without the inherent problems of cardiac arrhythmias, which often limit the assessment of left ventricular function. Because of its ability to accurately delineate wall motion abnormalities, the technique may provide an adequate assessment of global and regional left ventricular function after exercise. Digital subtraction angiography may identify ischemic wall motion abnormalities produced by exercise in patients who already had significant permanent left ventricular damage from myocardial infarction

  16. Evaluation of asymmetries of blood flow rate and of circulation time by intravenous radionuclide cerebral angiography in patients with ischemic completed stroke.

    Science.gov (United States)

    Bartolini, A; Primavera, A; Gasparetto, B

    1984-12-01

    155 patients with ischemic completed stroke of varying severity and outcome have been evaluated by radionuclide cerebral angiography with analysis of regional time-activity curves. Two parameters have been evaluated: area under the upslope of the curve (Aup) reflecting regional blood flow rate and moment of the whole curve reflecting tracer circulation time (rABCT) Combination of these two methods ensured increased detection of perfusion asymmetries.

  17. Valutazione morfo-funzionale in pazienti ipertesi con stenosi dell'arteria renale; Correlazioni tra angiografia e scintigrafia dinamica. Morpho-functional evaluation in hypertensive patients with renal artery stenosis; Correlations between angiography and radionuclide renography

    Energy Technology Data Exchange (ETDEWEB)

    Cuocolo, A; Celentano, L; Nappi, A [Naples Univ. (Italy). Ist. di Scienze Radiologiche; Neumann, R D; Salvatore, M [Naples Univ. (Italy). Cattedra di Medicina Nucleare

    1991-01-01

    Renovascula hypertension is the most important and common cause of secondary hypertension. We studied 10 patients with arterial hypertension and different degrees of renal artery stenosis to assess the usefulness of dynamic radionuclide renography in evaluating renal perfusion and funcion, and to compare funcional radionuclide results to the morphological findings of renal angiography. Computer-assisted dynamic renal with {sup 00m}Tc diethylenetriaminepentaacetic acid (DTPA) and {sup 131}I orthoiodohippurate (OIH), and renal artheriography were also employed in all patients. In all patients, radionuclide results matched angiography findings in quality. In particular, 3 patients with hemodynamical insignificant renal artery stenosis exhibited normal perfusion and function at dynamic radionuclide renography. Seven patients had significant renal artery stenosis and associated functional changes at dynamic radionuclide renography. Quantitative comparison of all patients showed a significant correlation (r=0.866, p<0.001) between the degree of renal artery stenosis, quantified as the percentage of narrowing as compared to adjacent/contralateral normal vessel diameter, and the results of split renal function, as assessed during OIH studies and expressed per kidney as a percentage of the net total counts of both kidneys. In conclusion, our results demonstrated dynamic radionuclide renography to be a valuable secondary to renal artery stenosis in hypertensive patients, providing complementary results to arteriography.

  18. The value of radionuclide angiography for risk assessment of patients following acute myocardial infarction

    International Nuclear Information System (INIS)

    Morris, K.G.

    1985-01-01

    Radionuclide angiography (RNA) is an accurate noninvasive method for the evaluation of left ventricular function at rest and exercise. Both the change in ejection fraction from rest to exercise and the exercise ejection fraction correlate with the severity of coronary artery disease and are more sensitive than ST-segment changes for detecting abnormalities due to exercise-induced myocardial ischemia. The amount of left ventricular dysfunction produced acutely by myocardial ischemia appears to vary linearly with the severity of ischemia produced. Thus rest and exercise RNA provide information noninvasively regarding both the severity of left ventricular dysfunction and the amount of potentially ischemic myocardium, two of the three major pathophysiologic mechanisms related to prognosis. It is reasonable to hypothesize that rest and exercise RNA may provide useful prognostic information concerning subsequent mortality and morbidity in survivors of acute myocardial infarction

  19. Comparison of exercise radionuclide angiography with thallium SPECT imaging for detection of significant narrowing of the left circumflex coronary artery

    International Nuclear Information System (INIS)

    Dilsizian, V.; Perrone-Filardi, P.; Cannon, R.O. III; Freedman, N.M.; Bacharach, S.L.; Bonow, R.O.

    1991-01-01

    Although quantitation of exercise thallium tomograms has enhanced the noninvasive diagnosis and localization of coronary artery disease, the detection of stenosis of the left circumflex coronary artery remains suboptimal. Because posterolateral regional wall motion during exercise is well assessed by radionuclide angiography, this study determined whether regional dysfunction of the posterolateral wall during exercise radionuclide angiography is more sensitive in identifying left circumflex disease than thallium perfusion abnormalities assessed by single-photon emission computed tomography (SPECT). One hundred ten consecutive patients with CAD were studied, of whom 70 had a significant stenosis of the left circumflex coronary artery or a major obtuse marginal branch. Both regional function and segmental thallium activity of the posterolateral wall were assessed using visual and quantitative analysis. Left ventricular regional function was assessed objectively by dividing the left ventricular region of interest into 20 sectors; the 8 sectors corresponding to the posterolateral free wall were used to assess function in the left circumflex artery distribution. Similarly, using circumferential profile analysis of short-axis thallium tomograms, left ventricular myocardial activity was subdivided into 64 sectors; the 16 sectors corresponding to the posterolateral region were used to assess thallium perfusion abnormalities in the left circumflex artery territory. Qualitative posterolateral wall motion analysis detected 76% of patients with left circumflex coronary artery stenosis, with a specificity of 83%, compared with only 44% by qualitative thallium tomography (p less than 0.001) and a specificity of 92%

  20. Sensitivity of computer assisted radionuclide angiography in transient ischemic attack and prolonged reversible ischemic neurological deficit. Comparison with findings in radiographic angiography and transmission computerized axial tomography

    International Nuclear Information System (INIS)

    Buell, U.; Scheid, K.F.; Lanksch, W.; Kleinhans, E.; Ulbert, V.; Reger, U.; Rath, M.; Moser, E.A.

    1981-01-01

    Computer assisted radionuclide angiography (CARNA) with 99mTc-DTPA was employed to study 143 patients with transient ischemic attacks (TIA) and 79 patients with prolonged reversible ischemic neurologic deficit (PRIND). The results of CARNA were compared with findings from radiographic angiography (RGA) in 173 patients and with findings in transmission computerized axial tomography (T-CAT) in 154 patients. In patients with TIA, CARNA showed a hemispherical perfusion deficit in 74.8%, and with PRIND 87.3%. This deficit, determined as the relative difference between the involved and the non-involved hemisphere, was significantly (p less than 0.0025) greater in PRIND (minus 23%) than in TIA (minus 17%). Sensitivity of CARNA was independent of the interval from ictus to examination for more than 4 months. RGA in TIA revealed true positives in 82.0%, in PRIND it was 89.5%. T-CAT was positive in TIA in only 16.8% but in PRIND it was 64.4%. Combined sensitivities in TIA (92.4%) and in PRIND (94.0%) were highest with the combination of CARNA and RGA. However, in PRIND the combination of non-invasive methods (CARNA and T-CAT) revealed 93.2% positive findings. Combinations of these evaluation methods may be used to detect cerebrovascular disease in patients with such dysfunction

  1. The role of radionuclide studies in emergency cases

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Hayashida, Kohei; Uehara, Toshiisa

    1982-01-01

    Radionuclide studies have been performed popularly because of its noninvasive and simple method recently. In this study, we applied this technique for the evaluation of emergency cases in cardiovascular diseases. There were 93 cases (1.5%) out of 6163 cases, done during 1981. The subjects were 34 cases of cardiac studies (9 cases of sup(99m)Tc-PYP myocardial imaging, 12 cases of thallium myocardial imaging, 13 cases of cardioangiography), 23 cases of peripheral diseases (12 cases of peripheral angiography, 11 cases of venography), 16 cases of pulmonary imaging, 10 cases of renal studies (6 cases of renal angiography, 9 cases of renal imaging) and 5 cases of brain angiography. These studies were proven to be useful clinically for the evaluation of emergency cases and follow-up studies. In the near future, ''emergency radionuclide studies'' would be benefit for the high-risk patients noninvasively. (author)

  2. Response of left ventricular ejection fraction to recovery from general anesthesia: measurement by gated radionuclide angiography

    International Nuclear Information System (INIS)

    Coriat, P.; Mundler, O.; Bousseau, D.; Fauchet, M.; Rous, A.C.; Echter, E.; Viars, P.

    1986-01-01

    To test the hypothesis that, after anesthesia for noncardiac surgical procedures, the increased cardiac work during recovery induces wall motion and ejection fraction (EF) abnormalities in patients with mild angina pectoris, gated radionuclide angiography was performed in patients undergoing simple cholecystectomy under narcotic-relaxant general anesthesia. The ejection fraction was determined during anesthesia at the end of surgery, and then determined 3 min and 3 hr after extubation. A new angiography was performed 24 hr later, and a myocardial scintigraphy (Thallium 201) was performed during infusion of the coronary vasodilator, dipyridamole. In the first part of the investigation, eight patients without coronary artery disease (CAD) (group 1) and 20 patients with mild angina (group 2) were studied. In the second part of the study, seven patients (group 3) with mild angina pectoris received an intravenous infusion of 0.4 microgram X kg-1 X min-1 of nitroglycerin started before surgery and gradually decreased 4 hr after extubation. In group 1, EF remained unchanged at recovery. In contrast in group 2, EF responded abnormally to recovery: EF decreased from 55% during anesthesia to 45% 3 min after extubation (P less than 0.001). Patients in group 3, who received intravenous nitroglycerin, showed no change of EF at recovery. This study demonstrates that recovery from general anesthesia causes abnormalities in left ventricular function in patients suffering from CAD. These abnormalities are prevented by prophylactic intravenous nitroglycerin

  3. The estimation of the liver perfusion in cirrhosis and liver tumours by radionuclide angiography

    International Nuclear Information System (INIS)

    Artiko, V.; Obradovic, V.; Kostic, K.; Petrovic, M.; Davidovic, B.; Perisic-Savic, M.; Janosevic, S.

    2004-01-01

    Purpose: The aim of the study is assessment of the hepatic perfusion index (HPI) in cirrhosis and focal liver diseases. Methods: Hepatic radionuclide angiography (HRA) was performed with bolus injection of 740 MBq- 99m-Tc-pertechnetate, during one minute (If/sec), using gamma camera, in 10 controls, 35 cirrhotic patients and 34 patients with different liver tumors. Results: In 10 controls (C), HPI was 0.68+/-0.06; it was significantly decreased (p 0.05), HPI values were significantly lower in LCEV (p 0.05).In 22 patients with liver hemangiomas (LH, X= 0.64 +/-0.08) HPI values were physiological (C-LH, p>0.05). However, in 4 patients with hepatocellular carcinoma (H, X=0.26+/-0.20), and 8 with liver metastases (LM, X=0.40 +/-0.28), HPI values were significantly decreased (p 0.05). Conclusion: HRA is a useful method for the asessment of different degrees of hemodynamic alterations in portal system, as well as for differential diagnosis of benign and malignant liver tumors. (authors)

  4. Fourier phase analysis on equilibrium gated radionuclide ventriculography: range of phase spread and cut-off limits in normal individuals

    International Nuclear Information System (INIS)

    Ramaiah, Vijayaraghavan L.; Harish, B.; Sunil, H.V.; Selvakumar, Job; Ravi Kishore, A.G.; Nair, Gopinathan

    2011-01-01

    To define the range of phase spread on equilibrium gated radionuclide ventriculography (ERNV) in normal individuals and derive the cut-off limit for the parameters to detect cardiac dyssynchrony. ERNV was carried out in 30 individuals (age 53±23 years, 25 males and 5 females) who had no history of cardiovascular disease. They all had normal left ventricular ejection fraction (LVEF 55-70%) as determined by echocardiography, were in sinus rhythm, with normal QRS duration (≤120 msec) and normal coronary angiography. First harmonic phase analysis was performed on scintigraphic data acquired in best septal view. Left and right ventricular standard deviation (LVSD and RVSD, respectively) and interventricular mechanical delay (IVMD), the absolute difference of mean phase angles of right and left ventricle, were computed and expressed in milliseconds. Mean + 3 standard deviation (SD) was used to derive the cut-off limits. Average LVEF and duration of cardiac cycle in the study group were 62.5%±5.44% and 868.9±114.5 msec, respectively. The observations of LVSD, RVSD and right and left ventricular mean phase angles were shown to be normally distributed by Shapiro-Wilk test. Cut-off limits for LVSD, RVSD and IVMD were calculated to be 80 msec, 85 msec and 75 msec, respectively. Fourier phase analysis on ERNV is an effective tool for the evaluation of synchronicity of cardiac contraction. The cut-off limits of parameters of dyssynchrony can be used to separate heart failure patients with cardiac dyssynchrony from those without. ERNV can be used to select patients for cardiac resynchronization therapy. (author)

  5. Equilibrium and generators

    International Nuclear Information System (INIS)

    Balter, H.S.

    1994-01-01

    This work studies the behaviour of radionuclides when it produce a desintegration activity,decay and the isotopes stable creation. It gives definitions about the equilibrium between activity of parent and activity of the daughter, radioactive decay,isotope stable and transient equilibrium and maxim activity time. Some considerations had been given to generators that permit a disgregation of two radioisotopes in equilibrium and its good performance. Tabs

  6. Radionuclide hepatic perfusion index and ultrasonography: Assessment of portal hypertension in clinical practice

    International Nuclear Information System (INIS)

    Seidlova, V.; Hobza, J.; Pumprla, J.; Charouzek, J.

    1989-01-01

    The application is described of radionuclide angiography with hepatic perfusion index (HPI) determination in diagnosis of portal blood flow as an indicator of portal hypertension. 99m Tc and 113 In were used as tracers. Over forty patients suffering from chronic hepatitis or liver cirrhosis were included in the study. Ultrasound was used as a preliminary rapid diagnosis of portal hypertension. Radionuclide angiography combined with the HPI technique was confirmed to be a beneficial noninvasive method offering reproducible quantitative information on portal flow well correlating with the degree of portal hypertension, while the combination of ultrasound examination with radionuclide HPI determination appears to greatly enrich the diagnostic potential in hepatology. (L.O.). 4 figs., 11 refs

  7. Present status and problems of radionuclide studies in emergency cases

    International Nuclear Information System (INIS)

    Ogawa, Kiyoshi

    1983-01-01

    Scintigraphy is just right for diagnosing emergency cases due to its noninvasive and simple method, but emergency radionuclide studies have not become practical as a result of difficulty problems. Recently, nuclear medical devices have become easier to use in operations. It is become of this, that I have submitted this report regarding the problems of radionuclide studies in emergency cases. There were 101 cases (1.4 %) out of 7,310 cases for the year period Sept. 1981 - Aug. 1982. The studies consisted of 12 brain imaging cases, 9 plumonary imaging cases, 22 cardiac study cases (cardio-angiography cases 8, 99m-Tc-PYP myocardium imaging cases 12, 201-Tl myocardium imaging cases 2), 12 renal study cases, 11 G.I. blood loss cases, 35 peripheral angiography cases. In the near future, we will have to be ready to perform emergency radionuclide studies if the need arises. (author)

  8. Sensitivity and specificity of radionuclide equilibrium angiocardiography for detection of hemodynamically significant secundum atrial septal defect

    Energy Technology Data Exchange (ETDEWEB)

    Brunotte, F.; Laurens, M.H.; Itty, C.; Robert, J.; Cloez, J.L.; Marcon, F.; Pernot, C.

    1986-12-01

    To determine the value, of gated equilibrium angiography in secundum atrial septal defect (ASD) in children, the first pass pulmonic/systemic flow ratio (Qp/Qs) was compared with diastolic count ratio (DCR) and stroke count ratio (SCR) of the two ventricles. In 50 children we have found a correlation between Qp/Qs and DCR (r=0.71) and between Qp/Qs and SCR (r=0.66). For detection of significant atrial shunt (Qp/Qs>1.5) the sensitivity of DCR>2 was 0.81 and the specificity 0.75. For SCR>1.5 we sensitivity and specificity values of 0.87 and 0.71 respectively. Left and right ventricular ejection fractions were normal (0.67+-0.08 and 0.50+-0.07).

  9. EVALUATION OF RADIONUCLIDE ACCUMULATION IN SOIL DUE TO LONG-TERM IRRIGATION

    International Nuclear Information System (INIS)

    De Wesley Wu

    2006-01-01

    Radionuclide accumulation in soil due to long-term irrigation is an important part of the model for predicting radiation dose in a long period of time. The model usually assumes an equilibrium condition in soil with a constant irrigation rate, so that radionuclide concentration in soil does not change with time and can be analytically solved. This method is currently being used for the dose assessment in the Yucca Mountain project, which requires evaluating radiation dose for a period of 10,000 years. There are several issues associated with the method: (1) time required for the equilibrium condition, (2) validity of constant irrigation rate, (3) agricultural land use for a long period of time, and (4) variation of a radionuclide concentration in water. These issues are evaluated using a numerical method with a simple model built in the GoldSim software. Some key radionuclides, Tc-99, Np-237, Pu-239, and Am-241 are selected as representative radionuclides. The results indicate that the equilibrium model is acceptable except for a radionuclide that requires long time to accumulate in soil and that its concentration in water changes dramatically with time (i.e. a sharp peak). Then the calculated dose for that radionuclide could be overestimated using the current equilibrium method

  10. Tricuspid insufficiency detected by equilibrium gated radionuclide study

    International Nuclear Information System (INIS)

    Handler, B.; Pavel, D.G.; Lam, W.; Byrom, E.; Swiryn, S.; Pietras, R.; Rosen, K.M.

    1981-01-01

    The results of a gated radionuclide cardiac study are reported in a patient with biventricular failure and tricuspid insufficiency demonstrated by clinical evaluation, M-mode and 2-D sector echocardiography, and cardia catheterization. The processed gated radionuclide cardiac study showed a left ventricular/right ventricular stroke volume ratio of 0.5; expansion of the hepatic blood pool demonstrated by hepatic time activity curve and calculation of an '''expansion fraction''; and synchronous changes of count rate of the atrial and hepatic regions detected by phase analysis

  11. Benchmark studies of computer prediction techniques for equilibrium chemistry and radionuclide transport in groundwater flow

    International Nuclear Information System (INIS)

    Broyd, T.W.

    1988-01-01

    A brief review of two recent benchmark exercises is presented. These were separately concerned with the equilibrium chemistry of groundwater and the geosphere migration of radionuclides, and involved the use of a total of 19 computer codes by 11 organisations in Europe and Canada. A similar methodology was followed for each exercise, in that series of hypothetical test cases were used to explore the limits of each code's application, and so provide an overview of current modelling potential. Aspects of the user-friendliness of individual codes were also considered. The benchmark studies have benefited participating organisations by providing a means of verifying current codes, and have provided problem data sets by which future models may be compared. (author)

  12. The external jugular vein as an injection site in radionuclide angiography

    International Nuclear Information System (INIS)

    Humphrey, S.; Shelton, J.; Wollum, P.; Leguizamon, E.

    1982-01-01

    The first-pass radionuclide angiogram has been shown to be an effective method for evaluation of left ventricular function. When the first-pass technique is used, however, delivery of a compact radionuclide bolus is imperative. The external jugular vein is a safe, effective route of delivery for the bolus; it provides for a high quality, technically accurate test without deleterious effects to the patient

  13. Detection of coronary artery disease - comparison of exercise stress radionuclide angiocardiography and thallium stress perfusion scanning

    International Nuclear Information System (INIS)

    Jengo, J.A.; Freeman, R.; Brizendine, M.; Mena, I.; St. Mary Medical Center, Long Beach, Calif.)

    1980-01-01

    Exercise thallium scanning and stress radionuclide angiography were compared in 16 normal subjects and 42 patients with more than 75% coronary arterial obstruction in studies using upright exercise on a bicycle ergometer. Studies at rest were subsequently obtained. Exercise thallium scans in the control group were normal in 15 and showed a defect in 1. Ejection fraction increased in all 16. During exercise, regional wall motion increased uniformly. In the group with coronary artery disease, thallium scanning revealed a new defect in the distribution of the involved arteries in 24 patients. In 15 who had a defect at rest, no new defect developed, but in 9 of the 15 new segmental wall motion defects were evident on radionuclide angiography. With exercise, ejection fraction decreased slightly. Regional wall motion abnormalities developed in the areas corresponding to thallium defects in all. Thallium scanning had a 93% and radionuclide angiography a 98% sensitivity value in detecting coronary artery disease. The respective specificity values were 94 and 100%. In patients with prior myocardial infarction who manifested new exercise abnormalities, 50% showed new thallium defects and 81% new wall motion defects

  14. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France); University Bordeaux Segalen, Bordeaux Cedex (France); Bullier, Eric; Riviere, Annalisa [Hopital Haut-Leveque, CHU Bordeaux, Department of Nuclear Medicine, Pessac (France); Dromer, Claire [Hopital Haut-Leveque, CHU Bordeaux, Department of Respiratory Diseases, Pessac (France); Picard, Francois [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiology, Pessac (France); Billes, Marc-Alain [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiac Surgery, Pessac (France); Corneloup, Olivier [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France)

    2014-01-15

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  15. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    International Nuclear Information System (INIS)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu; Bullier, Eric; Riviere, Annalisa; Dromer, Claire; Picard, Francois; Billes, Marc-Alain; Corneloup, Olivier

    2014-01-01

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  16. Decay profiles of β and γ for a radionuclide inventory in equilibrium cycle of a BWR type reactor

    International Nuclear Information System (INIS)

    Salaices, M.; Sandoval, S.; Ovando, R.

    2007-01-01

    Presently work the β and γ radiation decay profiles for a radionuclides inventory in equilibrium cycle of a BWR type reactor is presented. The profiles are presented in terms of decay in the activity of the total inventory as well as of the chemical groups that conform the inventory. In the obtaining of the radionuclides inventory in equilibrium cycle the ORIGEN2 code, version 1 was used, which simulates fuel burnup cycles and it calculates the evolution of the isotopic composition as a result of the burnt one, irradiation and decay of the nuclear fuel. It can be observed starting from the results that the decrease in the activity for the initial inventory and the different chemical groups that conform it is approximately proportional to the base 10 logarithm of the time for the first 24 hours of having concluded the burnt one. It can also be observed that the chemical groups that contribute in more proportion to the total activity of the inventory are the lanthanides-actinides and the transition metals, with 39% and 28%, respectively. The groups of alkaline earth metals, halogens, metalloids, noble gases and alkaline metals, contribute with percentages that go from the 8 to 5%. The groups that less they contribute to the total activity of the inventory they are the non metals and semi-metals with smaller proportions that 1%. The chemical groups that more contribute to the energy of β and γ radiation its are the transition metals and the lanthanides-actinides with a change in the order of importance at the end of the 24 hours period. The case of the halogens is of relevance for the case of the γ radiation energy due that occupying the very near third site to the dimensions of the two previous groups. Additionally, the decay in the activity for the total inventory and the groups that conform it can be simulated by means of order 6 polynomials or smaller than describe its behavior appropriately. The results presented in this work, coupled to a distribution model

  17. Assessment of left ventricular volumes by magnetic resonance in comparison with radionuclide angiography, contrast angiography and echocardiography

    DEFF Research Database (Denmark)

    Møgelvang, J; Stokholm, K H; Saunamäki, K

    1992-01-01

    The present study shows that for assessment of LVEF, MRI and the standard methods seem to provide information of similar value. For absolute volume measurements, MRI and RNA are superior to single plane angiography and 2 DE using the modified Simpson-rule. The time consuming transversal MRI method...... quality, which is crucial especially in dilated ventricles containing stagnant or slowly moving blood....

  18. Arterial scan versus radiographic angiography in detection of shallow arterial ulcers

    International Nuclear Information System (INIS)

    Pollak, E.W.; Webber, M.M.; Cragin, M.D.; Wolfman, E.F. Jr.

    1977-01-01

    A comparison of 99m-technetium albumin aggregated arterial scan and radiographic angiography for detection of shallow intimal carotid artery ulcerations was made in a series of 12 anesthetized dogs, having a total of 16 acute arterial ulcerations. Radiographic angiography showed positive findings related to presence of stenosis or mural thrombosis in 12 instances. Direct visualization of ulceration was only exceptionally encountered. Arterial scan detected 14 of 16 intimal ulcers. The radionuclide method was reliable even in absence of stenosis or when only minimal mural thrombosis was present. Moreover, autopsy scan of the isolated arterial segments detected all 16 intimal lesions. These results indicate that the arterial scan was a more reliable method for detection of shallow arterial ulcers in this experimental model than radiographic angiography, especially when arterial lumen stenosis or mural thrombosis was minimal or absent

  19. The radionuclide migration model in river system

    International Nuclear Information System (INIS)

    Zhukova, O.M.; Shiryaeva, N.M.; Myshkina, M.K.; Shagalova, Eh.D.; Denisova, V.V.; Skurat, V.V.

    2001-01-01

    It was propose the model of radionuclide migration in river system based on principle of the compartmental model at hydraulically stationary and chemically equilibrium conditions of interaction of radionuclides in system water-dredge, water-sediments. Different conditions of radioactive contamination entry in river system were considered. The model was verified on the data of radiation monitoring of Iput' river

  20. Distinguish natural sources out of secular equilibrium with their parents or daughters in Gamma ray spectrum analyses

    International Nuclear Information System (INIS)

    Mao Yahong; Liu Yigang

    2005-01-01

    Objective: To determine materials containing natural radionuclides in or out secular equilibrium with their parents or daughters. Methods: In gamma ray spectrum analyses, the activity concentration of every daughter is the same as that of its parent when the material is in secular equilibrium. The activity concentrations of daughters and their parents are different when the material is out of secular equilibrium. Results: It is different to determine whether the exposures from these materials should be exempted that materials containing natural radionuclides are in or out of secular equilibrium with their parents or daughters. Conclusion: It is important to determine materials containing natural radionuclides in or out secular equilibrium with their parents or daughters in gamma ray spectrum analyses. (authors)

  1. Radionuclide transport in a single fissure

    International Nuclear Information System (INIS)

    Eriksen, T.E.

    1983-01-01

    Radionuclide migration have been studied in natural fissures orieted parallel to the axis of granite drill cores. A short pulse of the radionuclides solution was injected at one end of the fissure and the temporal change in radionuclide concentration of the eluate measured. After several hundred fissure volumes water had been pumped through the fissure following the radionuclide pulse the activity distribution on the fissure surfaces was measured. From the retardation of 152 Eu, 235 Np and 237 Pu it is concluded that these radionuclides are transported in the oxidation states Eu(III), Pu(IV) and Np(V). The distribution coefficients K sub (d) calculated from flow and activity distribution data on the basis of geometric surface area/volume ratios are of the same order as published K sub (d) values obtained from batch equilibrium experiments. (Author)

  2. Clinical application of radionuclide cardiac study to the right heart diseases

    International Nuclear Information System (INIS)

    Shimizu, Tatsuro; Ozaki, Masaharu; Ikezono, Tohru

    1984-01-01

    We experienced the four cases of rare right heart diseases: those are two-chambered right ventricle, ball thrombus in right ventricle, right ventricular hypertrophy and tricuspid valve regurgitation due to multiple pulmonary infarction, and right ventricular and right atrial infarction. The preoperative or ante mortem diagnosis of these diseases is difficult, especially by use of a noninvasive technique. This report shows the usefulness of radionuclide cardiac study for diagnosis of these cases. In the two-chambered right ventricle, abnormal muscle bundle was visualized by 201 Tlcl and was observed as the filling defect by sup(99m)Tc-HSA radionuclide angiography. The ball thrombus showed the filling defect of sup(99m)Tc-HSA in the right ventricle but was not extracted by 201 Tlcl in the site of the defect area. In the multiple pulmonary infarction, the right ventricular free wall was visualized by 201 Tlcl, and during right ventricular systole, regurgitation from right atrium to inferior vena cava was noticed by means of sup(99m)Tc-HSA radionuclide angiography. These findings suggested right ventricular hypertrophy and tricuspid valve regurgitation. In the right ventricular and right atrial infarction, right ventricular ejection fraction and right atrial fractional emptying were lower than those of normal controls. (author)

  3. Limitations of radionuclide flow studies in bilateral carotid thrombosis

    International Nuclear Information System (INIS)

    Messert, B.; Tyson, I.B.; Barron, S.A.

    1975-01-01

    Radionuclide angiography as a noninvasive procedure has become an important tool in the evaluation of cerebrovascular diseases. Determinations of arm-to-brain circulation times complemented by the transit times of the radionuclide bolus through the brain afford insight into the functional status of the vascular system of the brain. Delays in perfusion, asymmetries in appearance, and washout of the radionuclide material can be correlated with disease entities. However, as with many procedures elevated to the status of a screening test, the possibility of false-positive and false-negative results exists. Two cases of bilateral carotid occlusion are presented, showing normal or only delayed, fairly symmetrical brain perfusion. The appearance of the radionuclide flow in the neck in AP and lateral views gave no suggestion of the involved deficits. Even multiple-projection imaging might fail to demonstrate major vascular obstructions. However, attentive study of these projections might yield interesting evidence of unexpected collateral flow systems. (U.S.)

  4. Influence of speciation on the geospheric migration of radionuclides

    International Nuclear Information System (INIS)

    Hadermann, J.; Schweingruber, M.

    1982-01-01

    For geosphere transport calculations in safety analyses of waste repositories it is generally assumed that the retardation of a migrating radionuclide is characterized by a single retention factor. However, in groundwater, radionuclides exist in various chemical forms with strongly differing sorption properties. We consider the effect of pseudo first order chemical reactions in liquid phase on migration. Conditions are derived under which local equilibrium in liquid phase is well fulfilled and migration is governed by a single effective retention factor. It is argued that in geosphere transport, equilibrium is likely to exist even when laboratory measurements show chromatographic separations. (author)

  5. Evaluation of diastolic phase by left ventricular volume curve using s2-gated equilibrium method among radioisotope angiography

    International Nuclear Information System (INIS)

    Watanabe, Yoshirou; Sakai, Akira; Inada, Mitsuo; Shiraishi, Tomokuni; Kobayashi, Akitoshi

    1982-01-01

    S2-gated (the second heart sound) method was designed by authors. In 6 normal subjects and 16 patients (old myocardial infarction 12 cases, hypertension 2 cases and aortic regurgitation 2 cases), radioisotope (RI) angiography using S2-gated equilibrium method was performed. In RI angiography, sup(99m)Tc-human serum albumin (HSA) 555MBq (15mCi) as tracer, PDP11/34 as minicomputer and PCG/ECG symchromizer (Metro Inst.) were used. Then left ventricular (LV) volume curve by S2-gated and electrocardiogram (ECG) R wave-gated method were obtained. Using LV volume curve, left ventricular ejection fraction (EF), mean ejection rate (mER, s -1 ), mean filling rate (mFR, -1 ) and rapid filling fraction (RFF) were calculated. mFR indicated mean filling rate during rapid filling phase. RFF was defined as the filling fraction during rapid filling phase among stroke volume. S2-gated method was reliable in evaluation of early diastolic phase, compared with ECG-gated method. There was the difference between RFF in normal group and myocardial infarction (MI) group (p < 0.005). RFF in 2 groups were correlated with EF (r = 0.82, p < 0.01). RFF was useful in evaluating MI cases who had normal EF values. The comparison with mER by ECG-gated and mFR by S2-gated was useful in evaluating MI cases who had normal mER values. mFR was remarkably lower than mER in MI group, but was equal to mER in normal group approximately. In conclusion, the evaluation using RFF and mFR by S2-gated method was useful in MI cases who had normal systolic phase indices. (author)

  6. Current status of radionuclide imaging in valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Boucher, C.A.; Okada, R.D.; Pohost, G.M.

    1980-12-18

    The current state-of-the-art in radionuclide imaging of valvular heart disease is based on different angiographic patterns in three left-sided valve abnormalities: pressure overload, volume overload, and inflow obstruction. In pressure overload, the left ventricle has normal dimensions or is minimally dilated the volume overload involves a left ventricular dilatation with a normal or reduced ejection fraction at rest the left ventricular function in inflow obstruction is normal, but in some cases may be depressed. Radionuclide angiography evaluates the effect of a valve abnormality on cardiac chamber and function thallium-201 imaging diagnoses regional myocardial blood flow and cell integrity and can evaluate the associated coronary artery disease.

  7. Current status of radionuclide imaging in valvular heart disease

    International Nuclear Information System (INIS)

    Boucher, C.A.; Okada, R.D.; Pohost, G.M.

    1980-01-01

    The current state-of-the-art in radionuclide imaging of valvular heart disease is based on different angiographic patterns in three left-sided valve abnormalities: pressure overload, volume overload, and inflow obstruction. In pressure overload, the left ventricle has normal dimensions or is minimally dilated the volume overload involves a left ventricular dilatation with a normal or reduced ejection fraction at rest the left ventricular function in inflow obstruction is normal, but in some cases may be depressed. Radionuclide angiography evaluates the effect of a valve abnormality on cardiac chamber and function thallium-201 imaging diagnoses regional myocardial blood flow and cell integrity and can evaluate the associated coronary artery disease

  8. Comparison of analytical charge-form and equilibrium thermodynamic speciation of certain radionuclides

    International Nuclear Information System (INIS)

    Jenne, E.A.; Cowan, C.E.; Robertson, D.E.

    1984-01-01

    Calculating trace element speciation with a thermodynamic model is often challenged on the basis that the existing thermodynamic data are not sufficiently reliable. Water quality data and corresponding analytical charge-form speciation analysis were available for radionuclides occurring in a low-level radioactive groundwater. This offered an opportunity for comparing the results of an equilibrium thermodynamic model with the results of analytical charge-form speciation. The charge-form speciation was determined using the Battelle Large Volume Water Sampler, which contains consecutive layers of cation resin, anion resin and activated aluminum oxide for retention of cationic, anionic and non-ionic dissolved chemical species, respectively. The thermodynamic speciation of Cs, Cr, Fe, I, Mn, Mo, Na, and Zn was calculated using the MINTEQ geochemical model. Ce, Co, Tc, Np, Pm, and Sb were speciated by hand calculation. Excellent agreement between the analytically determined charge-form and the thermodynamic speciation was observed for 54 Mn, 144 Ce, 131 I, 24 Na, 137 Cs, 99 Mo, 99 Tc, 151 Pm, 239 Np. Organic complexation by natural and/or synthetic organics in the waters may be important in the speciation of 65 An, 60 Co, 131 I, 59 Fe and possibly 51 Cr. Both 124 Sb and 125 Sb appeared to be in redox disequilibria with the groundwater. 29 references, 2 tables

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography uses a catheter, x-ray ... are the limitations of Catheter Angiography? What is Catheter Angiography? Angiography is a minimally invasive medical test ...

  10. Radionuclide and dopplergraphic assessment of portal hepatic blood flow in opisthorchiasis

    International Nuclear Information System (INIS)

    Borodulin, V.G.; Ermolitskij, N.M.; Zavadovskaya, V.D.; Prosekina, N.M.; Borodulin, Yu.V.

    1996-01-01

    Dynamic studies of the portal blood flow were carried out in 88 patients using colloid radionuclide gold-198 and Tc-99m-phytate and in 84 patients by dopplerography. Radionuclide studies showed that both radiopharmaceutical adequately reflected the portal blood flow in the liver. Portal blood flow values obtained by the duplex echographic method were 0.7 times lower than these estimated by radionuclide indirect angiography. The authors come to a conclusions that the share of the liver in colloid capture should be taken into consideration for the correct estimation of the level of portal hepatic hemodynamics. Portal hepatic blood flow was found markedly reduced in patients with chronic opisthorchiasis in comparison with normal controls, this difference being more expressed in male patients [ru

  11. An international database of radionuclide concentration ratios for wildlife: development and uses

    International Nuclear Information System (INIS)

    Copplestone, D.; Beresford, N.A.; Brown, J.E.; Yankovich, T.

    2013-01-01

    A key element of most systems for assessing the impact of radionuclides on the environment is a means to estimate the transfer of radionuclides to organisms. To facilitate this, an international wildlife transfer database has been developed to provide an online, searchable compilation of transfer parameters in the form of equilibrium-based whole-organism to media concentration ratios. This paper describes the derivation of the wildlife transfer database, the key data sources it contains and highlights the applications for the data. -- Highlights: • An online database containing wildlife radionuclide transfer parameters is described. • Database underpins recent ICRP and IAEA data wildlife transfer compilations. • Database contains equilibrium based whole organism to media concentration ratios

  12. The efficiency of magnetic resonance angiography (MRA) in the diagnosis vertebrobasilar insufficiency (VBI)

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Hiroyuki; Ura, Masaharu; Ganaha, Akira; Yasuda, Shinobu; Noda, Yutaka [Ryukyus Univ., Nishihara, Okinawa (Japan). Faculty of Medicine

    2000-09-01

    Vertebrobasilar insufficiency (VBI) is found in many cases of vertigo in patients who visit otolaryngology clinics. But its symptoms tend to be transitory, and since objective findings cannot be obtained at the first examination it is difficult to diagnose. As a result, it is tentatively diagnosed based only on the past history or the outcome of an equilibrium test. It is useful to diagnose circulation insufficiency, the stenotic position or the degree of the vessels based on the angiography findings. However, an operation is dangerous and overly invasive and therefore surgery is often not performed in many cases. We performed magnetic resonance angiography (MRA) and found it to be easy to perform, safe, it required a short examination time and was not invasive. A total of 12 cases suspected to have VBI based on the findings of an equilibrium test, MRA was performed. We could identify the stenotic or obstructive position of the vessels in the vertebrobasilar system in six of the cases. In conclusion, MRA was found to have many advantages over angiography and thus was considered to be useful in making a definite diagnosis of VBI. (author)

  13. The efficiency of magnetic resonance angiography (MRA) in the diagnosis vertebrobasilar insufficiency (VBI)

    International Nuclear Information System (INIS)

    Maeda, Hiroyuki; Ura, Masaharu; Ganaha, Akira; Yasuda, Shinobu; Noda, Yutaka

    2000-01-01

    Vertebrobasilar insufficiency (VBI) is found in many cases of vertigo in patients who visit otolaryngology clinics. But its symptoms tend to be transitory, and since objective findings cannot be obtained at the first examination it is difficult to diagnose. As a result, it is tentatively diagnosed based only on the past history or the outcome of an equilibrium test. It is useful to diagnose circulation insufficiency, the stenotic position or the degree of the vessels based on the angiography findings. However, an operation is dangerous and overly invasive and therefore surgery is often not performed in many cases. We performed magnetic resonance angiography (MRA) and found it to be easy to perform, safe, it required a short examination time and was not invasive. A total of 12 cases suspected to have VBI based on the findings of an equilibrium test, MRA was performed. We could identify the stenotic or obstructive position of the vessels in the vertebrobasilar system in six of the cases. In conclusion, MRA was found to have many advantages over angiography and thus was considered to be useful in making a definite diagnosis of VBI. (author)

  14. Aqueous geochemistry in icy world interiors: Equilibrium fluid, rock, and gas compositions, and fate of antifreezes and radionuclides

    Science.gov (United States)

    Neveu, Marc; Desch, Steven J.; Castillo-Rogez, Julie C.

    2017-09-01

    The geophysical evolution of many icy moons and dwarf planets seems to have provided opportunities for interaction between liquid water and rock (silicate and organic solids). Here, we explore two ways by which water-rock interaction can feed back on geophysical evolution: the production or consumption of antifreeze compounds, which affect the persistence and abundance of cold liquid; and the potential leaching into the fluid of lithophile radionuclides, affecting the distribution of a long-term heat source. We compile, validate, and use a numerical model, implemented with the PHREEQC code, of the interaction of chondritic rock with pure water and with C, N, S-bearing cometary fluid, thought to be the materials initially accreted by icy worlds, and describe the resulting equilibrium fluid and rock assemblages at temperatures, pressures, and water-to-rock ratios of 0-200 ° C, 1-1000 bar, and 0.1-10 by mass, respectively. Our findings suggest that water-rock interaction can strongly alter the nature and amount of antifreezes, resulting in solutions rich in reduced nitrogen and carbon, and sometimes dissolved H2, with additional sodium, calcium, chlorine, and/or oxidized carbon. Such fluids can remain partially liquid down to 176 K if NH3 is present. The prominence of Cl in solution seems to hinge on its primordial supply in ices, which is unconstrained by the meteoritical record. Equilibrium assemblages, rich in serpentine and saponite clays, retain thorium and uranium radionuclides unless U-Cl or U-HCO3 complexing, which was not modeled, significantly enhances U solubility. However, the radionuclide 40 K can be leached at high water:rock ratio and/or low temperature at which K is exchanged with ammonium in minerals. We recommend the inclusion of these effects in future models of the geophysical evolution of ocean-bearing icy worlds. Our simulation products match observations of chloride salts on Europa and Enceladus; CI chondrites mineralogies; the observation of

  15. Equilibrium radionuclide ventriculography in male patients after transmural myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Nestaval, A; Stanek, V; Malek, I; Kidery, J; Runczik, I [Institut pro Klinickou a Experimentalni Medicinu, Prague (Czechoslovakia); Cernoch, V; Oppelt, A [Institut pro Dalsi Vzdelavani Lekaru a Farmaceutu, Prague (Czechoslovakia)

    1982-12-17

    The ejection fraction of the left ventricle was measured using the method of equilibrium radionuclide ventriculography in 10 healthy males and 57 males after the first transmural myocardial infarction. The examination was effected 4 to 7 months after the event and the sample is representative for males after myocardial infarction who are younger than 65 years and show no signs of heart insufficiency by the time of examination. The resting value of the ejection fraction was 63+-5% in healthy males, 54+-7% in patients with uncomplicated myocardial infarction and 37+-8% in patients with clinical manifestations of heart insufficiency in acute phase. The differences between the groups are statistically significant. In patients with anteroseptal localization of myocardial infarction there was a negative correlation between the ejection fraction on the one hand and the sum of the voltages of Q waves in precordial ECG map and the maximum value of serum creatine kinase in acute phase on the other. The ejection fraction was in correlation to the degree of pulmonary hypertension measured in equal phase during exercise. The ejection fraction was measured in 31 patients under the working load of 50 W; significant changes were not found in healthy males or in patients after myocardial infarction. No changes were found when the state just before discharge from the hospital was compared with his state 6 months after myocardial infarction. The results obtained in compensated patients showed a relative stability of the value of the ejection fraction both during the first 6 months after discharge and under a mild working load. A comparison between the indicators in acute phase and hemodynamic examination after 6 months shows that the value of the ejection fraction is a sensitive indicator of the extent of necrosis and functional lesion of the left ventricle.

  16. Assessment of left ventricular function: comparison between radionuclide angiography and semiquantitative two-dimensional echocardiographic analysis

    International Nuclear Information System (INIS)

    Gottsauner-Wolf, M.; Schedlmayer-Duit, J.; Porenta, G.; Gwechenberger, M.; Huber, K.; Glogar, D.; Probst, P.; Sochor, H.

    1996-01-01

    Measurement of global left ventricular function is important in the follow-up of cardiac patients and is a good prognostic indicator in acute cardiac situations. We compared quantitative measurements of global left ventricular function made with radionuclide angiography (RNA) and contrast cardiac ventriculography (CVG) to visual semiquantitative estimates from two-dimensional echocardiographic images (2D-echo). Three hundred and thirty-nine consecutive patients who underwent RNA were assessed with 2D-echo within 3 months. In addition, 92 of these patients also underwent CVG (correlation of ejection fraction between CVG and RNA: r=0.82; P<0.0001). The RNA mean ejection fractions in the four 2D-echo groups (0=normal, 1=slightly, 2=moderate, or 3=severe reduced left ventricular function) differed markedly (P<0.0001); however, there was overlapping among the groups (2D-echo score/RNA ejection fraction: 0=57.3%±12.8%; 1=46.0%±12.9%; 2=29.6%± 12.2%; and 3=24.6%±11.5%) and the difference between 2D-echo scores 2 and 3 was not significant. 2D-echo showed a good concordance in RNA classes (0=≥505; 1=35%-49%; 2=21%-34%; and 3=≤20% ejection fraction) 0 (133/166; 80%) and 3 (18/30; 60%) but low concordance in classes 1 (27/82; 33%) and 2 (21/61; 34%). For accurate assessment of global left ventricular ejection fraction, visual semiquantitative judgement of a 2D echocardiographic image is limited in comparison to CVG or RNA, especially in patients with a slight or moderate reduction in left ventricular ejection fraction. (orig.). With 2 figs., 2 tabs

  17. Radionuclide angiography and blood pool imaging to assess skin ulcer healing prognosis in patients with peripheral vascular disease

    International Nuclear Information System (INIS)

    Alazraki, N.; Lawrence, P.F.; Syverud, J.B.

    1984-01-01

    Several non-invasive diagnostic techniques including segmental limb blood pressures, skin fluoresence, and photo plethysmography, have been evaluated as predictors of skin ulcer healing in patients with peripheral vascular disease, but none are widely used. Using 20mCi of Tc-99m phosphate compounds, four phase bone scans were obtained, including (1) radionuclide angiogram (2) blood pool image (3) 2 hour and 4-6 hour static images and (4) 24 hour static delayed images. The first two phases were used to assess vacularity to the region of distal extremity ulceration; the last two phases evaluated presence or absence of osteomyelitis. Studies were performed in 30 patients with non-healing ulcers of the lower extremities. Perfusion to the regions of ulceration on images was graded as normal, increased, or reduced with respect to the opposite (presumed normal) limb or some other normal reference area. Hypervascular response was interpreted as good prognosis for healing unless osteomyelitis was present. Clinicians followed patients for 14 days to assess limb healing with optimum care. If there was no improvement, angiography and/or surgery (reconstructive surgery, sympathectomy, or amputation) was done. Results showed: sensitivity for predicting ulcer healing was 94%, specificity 89%. Patients who failed to heal their ulcers showed reduced perfusion, no hypervascular response, or osteomyelitis. Microcirculatory adequacy for ulcer healing appear predictable by this technique

  18. Technical investigation of cerebral blood flow measurements using the Patlak plot method. A contrivance for positioning of the gamma camera at data collection in radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Takaki, Akihiro; Okada, Kazuhiro; Urata, Johji; Yonehara, Toshiro [Saiseikai Kumamoto Hospital (Japan); Mizuta, Yoshihiko

    1999-02-01

    The time-activity curve for the aortic arch obtained from radionuclide angiography (RNA) is handled as an input function parameter according to the method of Matsuda et al., which determines regional cerebral blood flow non-invasively. The data are collected from a frontal view of the thorax captured by RNA by their method, however we encountered a case in which it was difficult to identify aortic arch in the data collection from the frontal view. The precise identification of the aortic arch was implemented when the RNA data were collected from the left anterior oblique view of the thorax. No significant difference was noted in the measured values between the data collection from the frontal view and from the left anterior oblique view. Our method seems to be useful modification of the Patlak plot method. (author)

  19. Angiography

    International Nuclear Information System (INIS)

    Grinnell, V.S.; Mehringer, C.M.; Hieshima, G.B.

    1987-01-01

    The history of angiography is short, with its centennial approaching. A very brief review of milestones begins with the discovery of x-rays in 1895. Only a few months later contrast agents too toxic for human use were being injected into cadavers, severed limbs, and animals. The next major developments came in the late 1970s when percutaneous translumbar aortography and cerebral angiography were described. Contrast agents were now less toxic, and clinically useful angiography was a reality. In 1953 a technique for percutaneous vascular catheterization which formed the basis of many catheterization techniques to follow was described. In the 1970s the development of less invasive diagnostic methods such as computed tomography and diagnostic ultrasound decreased the indications for angiography, but newer interventional techniques such as embolization therapy and angioplasty have taken up the slack. Angiography remains the most important way to demonstrate vascular diseases graphically. Specific techniques such as angioplasty and digital subtraction angiography will be dealt with in other chapters. The authors hope to provide an overview of major areas of angiographic utilization. The basic techniques of arterial puncture and catheterization have been well described elsewhere

  20. Characteristics of myocardial perfusion imaging and coronary artery angiography in patients of NIDDM complicated with AMI

    International Nuclear Information System (INIS)

    Zhao Peiqin; Zhao Jinhua; Qin Mingzhao; Dai HaoJie; Zhang Runwu; Xiao Fen

    2001-01-01

    Objective: To investigate the characteristic changes of myocardial perfusion imaging and coronary artery angiography in patients of acute myocardial infarction (AMI) with underlined type 2 diabetes mellitus. Methods: 25 type 2 diabetes mellitus patients were enrolled for having clinical manifestation of AMI. Ten inpatients with AMI of simple coronary heart disease origin were served as controls. All subjects underwent both myocardial perfusion imagings (resting and nitroglycerine invention) and coronary artery angiography. Results: Compared to controls (40%), type 2 diabetes mellitus + AMI group had higher rate of multivessel disease (60%). For type 2 diabetes mellitus + AMI patients, 129/400 segments (32.25%) showed fixed defect, 25/160 segments (15.62%) in controls. Conclusions: For type 2 diabetes mellitus + AMI group, myocardial perfusion defects are widely distributed and multivessel or severe stenosis is more often presented. Good correlation exists between abnormal segments and angiographic lesions in both the number of segments involved and the severity of the lesions. Radionuclide myocardial perfusion is therefore considered a useful screening test not inferior to angiography, especially for those who are not tolerant enough to undergoing angiography

  1. Radionuclide solubilities to be used in SKB 91

    International Nuclear Information System (INIS)

    Bruno, J.; Sellin, P.

    1992-06-01

    We have performed thermodynamic calculations in order to assess the solubility limits (source term) for selected radionuclides. Equilibrium solubilities for U, Pu, Np, Am, Th, Ra, Sn, Tc, Zr, Sn, Ni, Sm, Pa, Nb and Pd have been calculated in four waters, representing average fresh and saline granitic groundwaters under oxidizing and reducing conditions, respectively. The results from the calculations have been compared with the measured radionuclide concentrations in natural waters as well as in spent fuel leaching tests. (26 refs.)

  2. Induced renal artery stenosis in rabbits: magnetic resonance imaging, angiography, and radionuclide determination of blood volume and blood flow

    International Nuclear Information System (INIS)

    Mitchell, D.G.; Tobin, M.; LeVeen, R.; Tomaczewski, J.; Alavi, A.; Staum, M.; Kundel, H.

    1988-01-01

    To investigate the ability of MRI to detect alterations due to renal ischemia, a rabbit renal artery stenosis (RAS) model was developed. Seven rabbits had RAS induced by surgically encircling the artery with a polyethylene band which had a lumen of 1 mm, 1 to 2 weeks prior to imaging. The stenosis was confirmed by angiography, and the rabbits were then imaged in a 1.4 T research MRI unit. T1 was calculated using four inversion recovery sequences with different inversion times. Renal blood flow, using 113 Sn-microspheres, and regional water content by drying were then measured. The average T1 of the inner medulla was shorter for the ischemia (1574 msec) than for the contralateral kidney (1849 msec), while no change ws noted in the cortex. Ischemic kidneys had less distinct outer medullary zones on IR images with TI = 600 msec than did contralateral or control kidneys. Blood flow to both the cortex and medulla were markedly reduced in ischemic kidneys compared with contralateral kidneys (119.5 vs. 391 ml/min/100 gm for cortex and 19.8 vs. 50.8 ml/min/100 gm for medulla). Renal water and blood content were less affected. Our rabbit model of renal artery stenosis with MRI, radionuclide, and angiographic correlation has the potential to increase our understanding of MR imaging of the rabbit kidney

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of ...

  4. Model for radionuclide transport in running waters

    International Nuclear Information System (INIS)

    Jonsson, Karin; Elert, Mark

    2005-11-01

    , however, the approximation of equilibrium chemistry is assumed to be sufficient for order of magnitude predictions when a constant inflow of radionuclides is considered. A first sensitivity analysis of the model is performed in which different model parameters have been varied. At the time for the model development, almost no detailed site-specific information about e.g. channel geometry or sediment characteristics were available. Simulations were therefore performed for a hypothetical case, where the ranges of possible parameter values was based on literature information, generalizations from other stream systems and some site-specific information such as large-scale information of the morphology at the present sites. For order of magnitude predictions of the concentration or amount of radionuclides in the different parts of the stream ecosystem, a yearly mean value of the water flow was assumed to be sufficient. Therefore, the further sensitivity analyses were performed for constant flow conditions. The sensitivity analyses indicated that the main retention along the stream is due to uptake within the sediment. Initially, the uptake will cause a retardation of the solute transport. The sediment capacity is however limited and after saturation, the outflow of radionuclides in the longitudinal direction will be completely determined by the inflow to the system. The time for reaching this equilibrium and the equilibrium concentration in the sediment varies however with different conditions and radionuclides, e.g. due to sorption characteristics, sedimentation velocity and advective velocity within the sediment. The degree of variation caused by different factors is, however, different. In the simulations performed in this study, the time for reaching equilibrium ranges from less than a year to a couple of hundred years. For predictions of the dose to humans, the accumulated amount in the sediment should also be considered and not only the concentration in the stream water

  5. Model for radionuclide transport in running waters

    Energy Technology Data Exchange (ETDEWEB)

    Jonsson, Karin; Elert, Mark [Kemakta Konsult AB, Stockholm (Sweden)

    2005-11-15

    , however, the approximation of equilibrium chemistry is assumed to be sufficient for order of magnitude predictions when a constant inflow of radionuclides is considered. A first sensitivity analysis of the model is performed in which different model parameters have been varied. At the time for the model development, almost no detailed site-specific information about e.g. channel geometry or sediment characteristics were available. Simulations were therefore performed for a hypothetical case, where the ranges of possible parameter values was based on literature information, generalizations from other stream systems and some site-specific information such as large-scale information of the morphology at the present sites. For order of magnitude predictions of the concentration or amount of radionuclides in the different parts of the stream ecosystem, a yearly mean value of the water flow was assumed to be sufficient. Therefore, the further sensitivity analyses were performed for constant flow conditions. The sensitivity analyses indicated that the main retention along the stream is due to uptake within the sediment. Initially, the uptake will cause a retardation of the solute transport. The sediment capacity is however limited and after saturation, the outflow of radionuclides in the longitudinal direction will be completely determined by the inflow to the system. The time for reaching this equilibrium and the equilibrium concentration in the sediment varies however with different conditions and radionuclides, e.g. due to sorption characteristics, sedimentation velocity and advective velocity within the sediment. The degree of variation caused by different factors is, however, different. In the simulations performed in this study, the time for reaching equilibrium ranges from less than a year to a couple of hundred years. For predictions of the dose to humans, the accumulated amount in the sediment should also be considered and not only the concentration in the stream water

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... Z Catheter Angiography Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material ... vessels in the body. Angiography is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging ( ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic ... called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a catheter makes it ...

  9. CT coronary angiography vs. invasive coronary angiography in CHD

    Directory of Open Access Journals (Sweden)

    Anja Hagen

    2012-04-01

    Full Text Available Scientific background: Various diagnostic tests including conventional invasive coronary angiography and non-invasive computed tomography (CT coronary angiography are used in the diagnosis of coronary heart disease (CHD. Research questions: The present report aims to evaluate the clinical efficacy, diagnostic accuracy, prognostic value cost-effectiveness as well as the ethical, social and legal implications of CT coronary angiography versus invasive coronary angiography in the diagnosis of CHD. Methods: A systematic literature search was conducted in electronic data bases (MEDLINE, EMBASE etc. in October 2010 and was completed with a manual search. The literature search was restricted to articles published from 2006 in German or English. Two independent reviewers were involved in the selection of the relevant publications. The medical evaluation was based on systematic reviews of diagnostic studies with invasive coronary angiography as the reference standard and on diagnostic studies with intracoronary pressure measurement as the reference standard. Study results were combined in a meta-analysis with 95 % confidence intervals (CI. Additionally, data on radiation doses from current non-systematic reviews were taken into account. A health economic evaluation was performed by modelling from the social perspective with clinical assumptions derived from the meta-analysis and economic assumptions derived from contemporary German sources. Data on special indications (bypass or in-stent-restenosis were not included in the evaluation. Only data obtained using CT scanners with at least 64 slices were considered. Results: No studies were found regarding the clinical efficacy or prognostic value of CT coronary angiography versus conventional invasive coronary angiography in the diagnosis of CHD. Overall, 15 systematic reviews with data from 44 diagnostic studies using invasive coronary angiography as the reference standard (identification of obstructive

  10. Dependency of soil activity concentration on soil -biota concentration ratio of radionuclides for earthworm

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong Kwon; Kim, Byeong Ho; Jun, In; Lim, Kwang Muk; Choi, Yong Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    The transfer of radionuclides to wildlife (non-human biota) is normally quantified using an equilibrium concentration ratio (CR{sub eq}), defined as the radionuclide activity concentration in the whole organism (fresh weight) divided by that in the media (dry weight for soil). The present study describes the effect of soil radionuclide activity concentration on the transfer of {sup 137}Cs, {sup 85}Sr and {sup 65}Zn to a functionally important wildlife group, annelids, using a commonly studied experimental worm (E.andrei). Time-dependent whole body concentration ratios of {sup 137}Cs, {sup 85}Sr and {sup 65}Zn for the earthworm were experimentally measured for artificially contaminated soils with three different activity concentrations for each radionuclide which were considerably higher than normal background levels. Two parameters of a first order kinetic model, the equilibrium concentration ratio (CR{sub eq}) and the effective loss rate constant (k), were estimated by comparison of experimental CR results with the model prediction

  11. Osmium-191 → iridium-191m radionuclide generator: development and clinical application. Progress report, March 1, 1981-February 28, 1982

    International Nuclear Information System (INIS)

    Treves, S.; Cheng, C.

    1981-01-01

    A prototype osmium-191 (T 1/2 = 16 days) → iridium-191m (T 1/2 = 4.9 seconds) generator designed for first pass radionuclide angiography was developed in our laboratory (Os-191 → Ir-191m). Our generator had 14 to 20% Ir-191m yield and a 1 to 3 x 10 -3 % Os-191 breakthrough. Iridium-191m decays with emission of a 65 and a 129 keV photon in 50% and 25% abundance respectively. This radionuclide is advantageous for angiography since it provides higher photon flux and results in much lower radiation dose to the patient than Tc-99m. One objective of this research is to improve the Os-191 → Ir-191m generator for first pass radionuclide angiography at an increase in the Ir-191m yield and a decrease in the Os-191 breakthrough. In addition, we would like to develop an Os-191 → Ir-191m generator for continuous infusion which will be used for ECG gated blood pool ventriculography, venography, and arteriography. Another approach will be to develop a carrier free Os-191 → Ir-191m generator in combination with organic or inorganic exchangers. Iridium-191m from our current generator has been employed successfully in two patient studies for the quantitation left-to-right shunting and the measurement of right and left ventricular ejection fractions. These types of studies will be expanded and further evaluated

  12. Radionuclide evaluation of brain death

    International Nuclear Information System (INIS)

    Pjura, G.A.; Kim, E.E.

    1987-01-01

    The criteria employed for clinical determination of death have evolved in response to advances in life support and other medical technology. The technical feasibility of organ transplantation has amplified the need for a definition of brain death that can be applied in the shortest possible time in the presence of artificial maintenance of vegetative functions, including circulation. Radionuclide cerebral angiography is one of a group of diagnostic procedures that can be employed to confirm the clinical diagnosis of brain death through demonstration of absence of cerebral blood flow. The focus of this work is to assess its use as a confirmatory test for determination of brain death in the context of currently available alternative technologies

  13. The results of artificial radionuclides monitoring in the Baltic sea

    International Nuclear Information System (INIS)

    Astrauskiene, N.; Lukinskiene, M; Zemaitiene, G.

    1994-01-01

    Long-term radionuclides volume activity (v.a.) monitoring (1976-1990) data showed that measurement results obtained in steady observation station give reliable information of the coastal area of the Baltic sea radioactive equilibrium between atmosphere and surface water was observed in the coastal zone. Chernobyl Power Plant accident influenced upon the Baltic sea coastal water by radionuclides 137 Cs and 144 Ce. Radionuclide 90 Sr volume activity was practically unchangerable. The mechanism of radionuclides fallout from atmosphere are various. lt can be illustrated by 137 Cs and 144 Ce a.v. structure field variations in open sea and coastal zone near Juodkrante. The Baltic sea inhomogeneous contamination by radionuclide 137 Cs in 1988-1990 leads to equalization of 137 Cs v.a. in the surface waters and it causes v.a. increase in coastal waters. (author)

  14. Assessment of injection bolus in first-pass radionuclide angiography. Evaluation of injection site and needle size

    International Nuclear Information System (INIS)

    Tonami, Syuichi; Inagaki, Syoichi; Yasui, Masakazu; Sugishita, Kouki; Yoshita, Hisashi; Nakamura, Mamoru; Kuranishi, Makoto

    1996-01-01

    First-pass radionuclide angiography (FPRNA) using a multi-crystal gamma camera can correctly provide many quantitative and qualitative indices of left ventricular function as well as anatomic information. A compact injection bolus of radiotracer is, however, essential to the first-pass study since the temporal separation of cardiac chambers is required for the first-pass acquisition. To examine which factors affect the quality of an injection bolus, 327 patients who had FPRNA in the anterior projection were randomized for injection site of radiotracer (right or left external jugular veins, and right antecubital vein) and needle size (19- or 21-gauge). The injected bolus was assessed from the full width at half maximum (FWHM) of the bolus time-activity curve in the superior vena cava. As to injection site using a 19-gauge needle, an attemption through right external jugular vein (EJV) revealed the shortest FWHM of an injection bolus, followed by left EJV and right antecubital vein (AV). In right EJV 91% of injected bolus FWHM was less than 1.5 sec, which was significantly higher (p<0.001) than those of the other sites (left EJV: 70%. right AV: 65%). Approximately 7% of injection from left EJV and right AV, showed a split bolus of radiotracer. However, no split bolus was observed from right EJV. There was no significant difference in FWHM of an injection bolus between 19- and 21-gauge needle from EJV. Our present study demonstrated that the quality of an injection bolus from left EJV and AV was affected by RVEF in a case of low right ventricular function. In conclusion, right EJV is the first choice of injection site to obtain a compact bolus of radiotracer for the first-pass cardiac study. A 21-gauge needle can also be inserted from the external jugular vein to perform a good bolus injection. (author)

  15. Assessment of injection bolus in first-pass radionuclide angiography. Evaluation of injection site and needle size

    Energy Technology Data Exchange (ETDEWEB)

    Tonami, Syuichi; Inagaki, Syoichi; Yasui, Masakazu; Sugishita, Kouki; Yoshita, Hisashi; Nakamura, Mamoru; Kuranishi, Makoto [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    1996-09-01

    First-pass radionuclide angiography (FPRNA) using a multi-crystal gamma camera can correctly provide many quantitative and qualitative indices of left ventricular function as well as anatomic information. A compact injection bolus of radiotracer is, however, essential to the first-pass study since the temporal separation of cardiac chambers is required for the first-pass acquisition. To examine which factors affect the quality of an injection bolus, 327 patients who had FPRNA in the anterior projection were randomized for injection site of radiotracer (right or left external jugular veins, and right antecubital vein) and needle size (19- or 21-gauge). The injected bolus was assessed from the full width at half maximum (FWHM) of the bolus time-activity curve in the superior vena cava. As to injection site using a 19-gauge needle, an attemption through right external jugular vein (EJV) revealed the shortest FWHM of an injection bolus, followed by left EJV and right antecubital vein (AV). In right EJV 91% of injected bolus FWHM was less than 1.5 sec, which was significantly higher (p<0.001) than those of the other sites (left EJV: 70%. right AV: 65%). Approximately 7% of injection from left EJV and right AV, showed a split bolus of radiotracer. However, no split bolus was observed from right EJV. There was no significant difference in FWHM of an injection bolus between 19- and 21-gauge needle from EJV. Our present study demonstrated that the quality of an injection bolus from left EJV and AV was affected by RVEF in a case of low right ventricular function. In conclusion, right EJV is the first choice of injection site to obtain a compact bolus of radiotracer for the first-pass cardiac study. A 21-gauge needle can also be inserted from the external jugular vein to perform a good bolus injection. (author)

  16. Nuclear decay data for radionuclides occurring in routine releases from nuclear fuel cycle facilities

    Energy Technology Data Exchange (ETDEWEB)

    Kocher, D.C.

    1977-08-01

    This report gives tabulations of the atomic and nuclear radiations emitted by 240 radionuclides. Most of the radionuclides are those expected to occur in routine releases of effluents from nuclear fuel cycle facilities. For each radionuclide are given the half-life and recommended values for the energies, intensities, and equilibrium absorbed-dose constants for each of the atomic and nuclear radiations. Also given are the daughter radionuclides produced and recommended values for decay branching ratios, where applicable. The radioactivity decay chains and branching ratios are displayed in diagram form.

  17. Nuclear decay data for radionuclides occurring in routine releases from nuclear fuel cycle facilities

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1977-08-01

    This report gives tabulations of the atomic and nuclear radiations emitted by 240 radionuclides. Most of the radionuclides are those expected to occur in routine releases of effluents from nuclear fuel cycle facilities. For each radionuclide are given the half-life and recommended values for the energies, intensities, and equilibrium absorbed-dose constants for each of the atomic and nuclear radiations. Also given are the daughter radionuclides produced and recommended values for decay branching ratios, where applicable. The radioactivity decay chains and branching ratios are displayed in diagram form

  18. Multidetector-row CT angiography of hepatic artery: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Jeong, Yong Yeon; Yoon, Woong; Kim, Jae Kyu; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun

    2003-01-01

    To determine the usefulness of three-dimensional CT angiography using multidetector-row CT (MD-CT) for delineating the arterial anatomy of the liver. Hepatic arterial three-dimensional CT angiography was performed using MDCT (lightspeed Qx/I; GE medical systems, milwaukee, Wis., U.S.A.) in 45 patients with HCC undergoing conventional angiography for transcatheter hepatic arterial chemoembolization. The scanning parameters during the early arterial phase were 2.5 mm slice thickness, 7.5 mm rotation of table speed, and a pitch of 3. Images were obtained by one radiologist using maximum intensity projection from axial CT images obtained during the early arterial phase. Two radiologists blinded to the findings of conventional angiography independently evaluated the hepatic arterial anatomy and the quality of the images obtained. Compared with conventional angiography, reader A correctly evaluated the hepatic arterial anatomy depicted at three-dimensional CT angiography. Reader B's evaluation was correct in 40 of 45 patients. Interobserver agreement was good (kappa value, 0.73), and both readers assessed the quality of three-dimensional CT angiography as excellent. Three-dimensional CT angiography using MDCT was accurate for delineating the arterial anatomy of the liver, and interobserver agreement was good. The modality may provide, prior to conventional angiography, valuable information regrading a patient's hepatic arterial anatomy

  19. Development of the osmium-191 → iridium-191m radionuclide generator. Annual report

    International Nuclear Information System (INIS)

    Treves, S.; Packard, A.B.

    1985-01-01

    The use of /sup 191m/Ir in radionuclide angiography has been the subject of increasing interest in recent years. The 191 Os-/sup 191m/Ir generator that has been used for these studies suffers, however, from low /sup 191m/Ir yield (10%/ml) and higher than desirable 191 Os breakthrough (5 x 10 -3 %). We have recently developed a /sup 191m/Ir generator that has higher yield (25 to 30%/ml) and lower breakthrough ( -4 %) when eluted with an eluent (0.001 M oxalic acid/0.9% saline) that does not require buffering prior to injection. Studies within the last year have shown the eluate of this generator to be non-toxic at up to 100 times the expected human dose and work is in progress to obtain approval for human use of this system. While a significant improvement over past generator designs, the yield of this generator is still modest and the evaluation of new osmium complexes for use on the generator has continued. Clinical studies involving the use of /sup 191m/Ir for first-pass angiography in adults and children have continued. A comparison of ejection fractions measured in adults with both /sup 99m/Tc and /sup 191m/Ir has confirmed the feasibilty of /sup 191m/Ir for radionuclide angiography in both the left and right ventricles of adults. Studies in collaboration with Baylor Medical College have demonstrated the efficacy of /sup 191m/Ir in combination with the multi-wire gamma camera. 31 refs., 2 figs., 10 tabs

  20. Migration of radionuclide chains in subseabed disposal

    International Nuclear Information System (INIS)

    Ray, A.K.; Nuttall, H.E.

    1982-01-01

    In this study of subseabed disposal, the two dimensional (axial and radial) migration of radionuclide chains released from a canister located in a sedimentary layer bounded at the top by the ocean and at the bottom by an impermeable basalt zone is analyzed to determine the escape rate of radionuclides into the seawater. Analytical solutions have been derived to represent the transient concentration profiles within the sediment, flux and discharge rates to the water column of each member present in a decay chain. Using the properties of chain members present in actinide decay systems, the effects of half-life, adsorption equilibrium and other relevant parameters are elucidated. 4 figures, 1 table

  1. The equilibrium leach testing of ferric/aluminium hydroxide flocs

    International Nuclear Information System (INIS)

    Biddle, P.; Greenfield, B.F.; Greenham, P.S.; Rees, J.H.

    1987-09-01

    Equilibrium leach tests have been carried out on ferric/aluminium hydroxide flocs using cement and resin matrices, and cement and clay backfills in both air and nitrogen atmospheres. The equilibrium concentrations of a number of actinides and fission products were measured in leachates obtained over periods of up to a year. The lowest equilibrium actinide concentrations were found in leachates from systems with a cement backfill. Cement matrix-cement backfill was the most promising combination for limiting concentrations of long-lived radionuclides, resin-clay the least. Comparison of leachate concentrations with limiting drinking water concentrations are made and the high degree of protection afforded by candidate near field components shown. (author)

  2. The equilibrium leach testing of ferric/aluminium hydroxide flocs

    International Nuclear Information System (INIS)

    Biddle, P.; Greenfield, B.F.; Greenham, P.S.; Rees, J.H.

    1987-09-01

    Equilibrium leach tests have been carried out on ferric/aluminium hydroxide flocs using cement and resin matrices, and cement and clay backfills in both air and nitrogen atmospheres. The equilibrium concentrations of a number of actinides and fission products were measured in leachates obtained over periods of up to a year. The lowest equilibrium actinide concentrations were found in leachates from systems with a cement backfill. Cement matrix-cement backfill was the most promising combination for limiting concentrations of long-lived radionuclides, resin-clay the least. Comparisons of leachate concentrations with limiting drinking water concentrations are made and the high degree of protection afforded by candidate near field components shown. (author)

  3. Iridium-191m radionuclide angiocardiography detection and quantitation of left-to-rigth shunts

    International Nuclear Information System (INIS)

    Treves, S.; Fujii, A.; Cheng, C.; Kuruc, A.

    1983-01-01

    The purpose of this study was to determine whether Iridium-191m (Ir-191m) could replace Technetium-99m (Tc-99m) in the detection and quantitation of left-to-right shunts. It was demonstrated that Ir-191m radionuclide angiography is a safe, rapid, and accurate method for the detection and quantitation of left-to-right shunts with very low radiation dose to the patient. It is also possible with this radiotracer to evaluate other aspects of the anatomy and physiology of the circulation such as ventricular function, patency of major vessels, renal and cerebral perfusion. Further improvements on 0s-191 production, generator design and gamma cameras would expand the use of this ultrashort-lived radionuclide

  4. Natural radionuclides in Brazilian underground mines

    International Nuclear Information System (INIS)

    Santos, Talita de Oliveira

    2015-01-01

    Rock, soil and water contain "2"3"8U and "2"3"2Th and their decay products. The distribution of these radionuclides differs in terms of activity concentration depending on the mineral type and origin. All ore processing releases long and short half-life radionuclides, mainly radon and its progeny. It is important to monitor this gas and its decay products in underground mines in order to assess the radiological hazards of the exposed workers. On this concern, the present work outlines the characterization of brazilian underground mines with relation to natural radionuclides, specially radon and its progeny. The radon concentration was measured by using E-PERM Electrets Ion Chamber (Radelec), AlphaGUARD (Saphymo GmbH) and CR-39 (Landauer) track etch detectors. The radon progeny was determined by using DOSEman detector. The equilibrium state between radon and its progeny was calculated. Based on these data, the total effective dose for miners was estimated. Moreover, the contribution from the main sources to the radon level inside mines was evaluated. For this, the following detectors were used: measurements of radon concentrations in soil gas were carried out by using AlphaGUARD detector; "2"2"6Ra ("2"1"4Bi), "2"3"2Th e "4"0K specific activity in ore and soil samples were determined by using gamma-ray spectrometry HPGe detector (Canberra); and radon concentration in groundwater samples was performed by using RAD7 (Durridge Inc.). The radon concentration ranged from 113 to 8171 Bq.m"-"3 and the Equilibrium Equivalent Concentration varied from 76 to 1174 Bq.m"-"3. The equilibrium factor mean value was 0.4 (0.2 -0.7). The workers estimated total effective dose ranged from 1 to 22 mSv.a"-"1 (mean 10 mSv.a"-"1). Therefore, results show the importance to assess continually and permanently the radon and its progeny behavior and the need to adopt safety measurements against natural radiation in underground mines environment. (author)

  5. Imaging of the digital arteries: Digital subtraction angiography versus conventional angiography

    International Nuclear Information System (INIS)

    Menanteau, B.P.; Treutenaere, J.M.; Marcus, C.; Ladam, V.; Gausserand, F.

    1986-01-01

    The authors report their experience with the use of digital subtraction angiography (DSA) and conventional angiography of the hand. Of the 95 patients in the study group, 80 underwent conventional angiography and 15 underwent DSA. They analyzed the studies with regard to the type and amount of contrast agent used, the number of radiographs needed, and the diagnostic quality of the images. Conventional angiography often requires general anesthesia, magnification, and pharmaco-angiographic techniques to improve the image-based diagnosis. In comparison with conventional angiography, intraarterial DSA is characterized by improved contrast sensitivity and inferior spatial resolution. However, DSA provides images as acceptable as those of conventional angiography. Smaller catheters can be used, and the examination is performed under local anesthesia. The authors conclude that intraarterial DSA is now the technique of choice for examining patients with chronic ischemia of the hand

  6. MR-angiography

    International Nuclear Information System (INIS)

    Seiderer, M.

    1989-01-01

    Three categories of MRI techniques for vascular imaging are discussed: 2d-angiography using rephasing and dephasing pulse sequences and slice selective imaging; 3d-angiography using rehpasing and dephasing pulse sequences and fas 3d-imaging techniques; 3d-angiography using signal intensity modulation caused by pre- and post-contrast data acquisition (e.g. Gadolinium-DTPA) in combination with fast 3d-imaging (only one type of pulse sequence). (H.W.). 6 figs

  7. Natural radionuclide distribution in phosphate fertilizer and superphosphate production technology

    Energy Technology Data Exchange (ETDEWEB)

    Lisachenko, Eh P; Ponikarova, T M; Lisitsyna, Yu Z

    1987-01-01

    The obtained data on the natural radionuclide distribution by phosphate fertilizer and superphosphate production process stages testify to phosphate fertilizer enrichment 2-4 times in relation to initial ore, depending in the raw material used. In this case uranium and thorium series element concentration value (in equilibrium with their decomposition products), proposed as a regulating one in phosphorus-containing fertilizers, is not achieved. However, the fact of lurichment as it is and the enrichment factor, stated in the course of the work, should be taken into account for evaluation of phosphorite new deposit raw material with higher concentrations of natural radionuclides. Natural radionuclide separation in the enrichment process and superphosphate production is not revealed.

  8. Microembolism after cerebral angiography

    International Nuclear Information System (INIS)

    Manaka, Hiroshi; Sakai, Hideki; Nagata, Izumi

    2000-01-01

    Acute microemboli are detected more precisely with the recently developed diffusion-weighted MR imaging (DWI). We happened to obtain 24 DWIs after 350 diagnostic cerebral angiographies in 1999. DWIs after cerebral angiographies showed bright lesions in 7 patients (28%), of whom 6 had no neurological symptoms after cerebral angiography. Seven of the 24 patients had risk factors for arteriosclerosis. Only one patient had embolic events due to angiography. Microemboli related to cerebral angiographies are inevitable in some patients. Most are silent, however, we should investigate the cause of microemboli and should make cerebral angiography safer. (author)

  9. Evaluation of left ventricular function using digital subtraction angiography

    International Nuclear Information System (INIS)

    Kozuka, Takahiro; Ohta, Mitsushige

    1985-01-01

    To evaluate function of the left ventricle and myocardial perfusion images, digital subtraction angiography (DSA) was performed in 45 patients with ischemic heart disease. Validity of the technique was compared with data obtained from cine left ventriculogram in all patients and 201 T1 myocardial images in 20 patients. End-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) calculated from DSA were correlated closely with those from cine left ventriculogram (r = 0.92, r = 0.94 and r = 0.86, respectively). Regional contractility at the antero-lateral wall of the left ventricle, assessed by DSA, was also correlated well with cine left ventriculogram (r = 0.75). Evaluation of the inferior wall motion showed less correlation in both procedures (r = 0.68). Phase and amplitude analysis with the same technique with radionuclide cardiac angiography was successfully applied in left ventriculogram obtained by DSA. The procedure seems to be helpful for objective evaluation of the left ventricular wall motion. Myocardial perfusion image, obtained with modified Radtke's technique, showed good coincidence with 201 T1 images. Thus, DSA is applicable for evaluation of function of the left ventricle and myocardial perfusion in patients with ischemic heart disease. (author)

  10. Pediatric CT angiography

    International Nuclear Information System (INIS)

    Siegel, M.J.

    2005-01-01

    Advances in CT technology are having profound impact on imaging children and have made CT angiography possible even in neonates. Even with the tiny anatomy of neonates, small volumes of contrast material, and small venous access catheters, successful CT angiography can be performed with attention to detail. Meticulous attention to patient preparation, the proper selection of technical factors, and optimal delivery of contrast material are crucial. Data post-processing and the creation of 3-D reconstructions are also essential in establishing a correct diagnosis. The applications fo CT angiography are different in children than in adults and most applications in children involve assessment of congenital and postoperative vascular and cardiac diseases. The use of CT angiography offers the opportunity to eliminate the long periods of sedation associated with MR and reduce the radiation exposure associated with conventional angiography. Generally, the benefits of CT angiography in children outweigh the risk, namely that of radiation exposure. However, care must still be taken to minimize the radiation exposure. (orig.)

  11. The role of high temperature heterogeneous reaction kinetics in the rate of radionuclide vaporisation during core-concrete interactions

    International Nuclear Information System (INIS)

    Raymond, D.P.; Clough, P.N.

    1989-09-01

    Heterogeneous reactions may cause enhanced release of radionuclides during the core-concrete interaction (CCl) stage of a PWR severe accident. The VANESA computer code models these CCI releases using chemical equilibrium assumptions; however, the possibility that chemical kinetics could prevent equilibrium from being achieved is considered in this report. Direct experimental evidence is lacking on these reactions. Therefore, some analogues studies are reviewed, including examples of Eyring's surface reaction rate theory; sequential vaporisation-oxidation processes; iron and steelmaking chemistry; radionuclide evaporation from solid UO 2 . This circumstantial evidence appeared to agree with the current assumptions, in VANESA and some UK modelling studies, that mass transfer, rather than chemical kinetics will limit the rate at which equilibrium is attained. (author)

  12. BLT-EC (Breach, Leach Transport, and Equilibrium Chemistry), a finite-element model for assessing the release of radionuclides from low-level waste disposal units: Background, theory, and model description

    International Nuclear Information System (INIS)

    MacKinnon, R.J.; Sullivan, T.M.; Simonson, S.A.; Suen, C.J.

    1995-08-01

    Performance assessment models typically account for the processes of sorption and dissolution-precipitation by using an empirical distribution coefficient, commonly referred to as K d that combines the effects of all chemical reactions between solid and aqueous phases. In recent years, however, there has been an increasing awareness that performance assessments based solely on empirically based K d models may be incomplete, particularly for applications involving radionuclides having sorption and solubility properties that are sensitive to variations in the in-situ chemical environment. To accommodate variations in the in-situ chemical environment, and to assess its impact on radionuclide mobility, it is necessary to model radionuclide release, transport, and chemical processes in a coupled fashion. This modeling has been done and incorporated into the two-dimensional, finite-element, computer code BLT-EC (Breach, Leach, Transport, Equilibrium Chemistry). BLT-EC is capable of predicting container degradation, waste-form leaching, and advective-dispersive, multispecies, solute transport. BLT-EC accounts for retardation directly by modeling the chemical processes of complexation, sorption, dissolution-precipitation, ion-exchange, and oxidation-reduction reactions. In this report we: (1) present a detailed description of the various physical and chemical processes that control the release and migration of radionuclides from shallow land LLW disposal facilities; (2) formulate the mathematical models that represent these processes; (3) outline how these models are incorporated and implemented in BLT-EC; and (4) demonstrate the application of BLT-EC on a set of example problems

  13. Assessment of sistemic ventricle function in corrected transposition of great arteries with Gated SPECT: comparison with radionuclide ventriculography

    International Nuclear Information System (INIS)

    Alexanderson, E.; Espinola, N.; Duenas, D.; Fermon, S.; Acevedo, C.; Martinez, C.

    2002-01-01

    Corrected trasposition of great arteries is a uncommon congenital heart disease where the right ventricle works as the sistemic one. QGS Gated SPECT program was designed to recognize the contours of left ventricle being a good method to evaluate left ventricle ejection fraction. The purpose of this study was to evaluate the right ventricle ejection fraction (RVEF) by gated SPECT using Tc-99mSestaMIBI in comparison with radionuclide ventriculography (RVG) in patients with corrected trasposition of great arteries. Methods: We performed gated SPECT and radionuclide ventriculography within 15 days of each other in 7 adults consecutive patients with the diagnosis of corrected trasposition of great arteries (5 men, 2 women; mean age 47 y). Gated tomographic data, including ventricular volumes and ejection fraction, were processed using QGS automatic algorithm, whereas equilibrium radionuclide ventriculography used standard techniques. Results: We found a good correlation between right ventricle ejection fraction obtained with Gated SPECT compared with equilibrium radionuclide ventriculography. The mean of the RVEF with Gated SPECT was 41.2% compared with 44.2% of RVEF with equilibrium radionuclide ventriculography. Both methods recognized abnormal RVEF in 5 patients ( 50%) with Gated SPECT and abnormal with RVG meanwhile another patient had normal RVEF with RVG and abnormal with Gated SPECT. Conclusion: Quantitative gated tomography, using Tc 99mSestaMIBI, has a good correlation with radionuclide ventriculography for the assessment of right ventricle ejection fraction in patients with corrected trasposition of great arteries. These results support the clinical use of this technique among these patients

  14. An Exact Solution for the Assessment of Nonequilibrium Sorption of Radionuclides in the Vadose Zone

    International Nuclear Information System (INIS)

    Drake, R. L.; Chen, J-S.

    2002-01-01

    In a report on model evaluation, the authors ran the HYDRUS Code, among other transport codes, to evaluate the impacts of nonequilibrium sorption sites on the time-evolution of 99Tc and 90Sr through the vadose zone. Since our evaluation was based on a rather low, annual recharge rate, many of the numerical results derived from HYDRUS indicated that the nonequilibrium sorption sites, in essence, acted as equilibrium sorption sites. To help explain these results, we considered a ''stripped-down'' version of the HYDRUS system. This ''stripped-down'' version possesses two dependent variables, one for the radionuclides in solution and the other for the radionuclides adsorbed to the nonequilibrium sites; and it possesses constant physical parameters. The resultant governing equation for the radionuclides in solution is a linear, advection-dispersion-reaction (i.e., radioactive decay) partial differential equation containing a history integral term accounting for the nonequilibrium sorption sites. It is this ''stripped-down'' version, which is the subject of this paper. We found an exact solution to this new version of the model. The exact solution is given in terms of a single definite integral of terms involving elementary functions of the independent variables and the system parameters. This integral possesses adequate convergence properties and is easy to evaluate, both in a quantitative matter and in a qualitative manner. The parameters that are considered in the system are as follows: the radionuclide's equilibrium partition coefficient between water and soil, the bulk density of the soil, the fractions of equilibrium/nonequilibrium sorption sites, the volumetric water content, the first order equilibrium adsorption rate constant, the first order radioactive decay rate constant, the liquid water soil tortuosity factor, the molecular diffusion coefficient in water, the longitudinal dispersivity factor, and the Darcian fluid flux density. In addition, the system

  15. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography ...

  16. Radionuclide investigation of the blood flow in tumor and normal rat tissues in induced hyperglycemia

    International Nuclear Information System (INIS)

    Istomin, Yu.P.; Shitikov, B.D.; Markova, L.V.

    1991-01-01

    Radionuclide angiography was performed in rats with transplantable tumors. Induced hyperglycemia was shown to result in blood flow inhibition in tumor and normal tissues of tumor-bearing rats. Some differences were revealed in a degree of reversibility of blood flow disorders in tissues of the above strains. The results obtained confirmed the advisability of radiation therapy at the height of a decrease in tumor blood

  17. Magnetic resonance angiography (MRA)

    International Nuclear Information System (INIS)

    Arlart, I.P.; Guhl, L.

    1992-01-01

    An account is given in this paper of the physical and technical principles underlying the 'time-of-flight' technique for imaging of vessels by magnetic resonance tomography. Major indications for the new procedure of magnetic resonance angiography at present are intracerebral and extracerebral vessels, with digital subtraction angiography quite often being required to cope with minor alterations (small aneurysms, small occlusions). Magnetic resonance angiography and digital subtraction angiography are compared to each other for advantages and disadvantages. Basically, replacement of radiological angiography by magnetic resonance angiography appears to be possible only within limits, since X-ray diagnostics primarily provides morphological information about vessels, whereas flow dynamics is visualized by the 'time-of-flight' technique. (orig.) [de

  18. Value of radionuclide angiocardiography for determination of left ventricular volume in patients with valvular heart diseases (preliminary report)

    International Nuclear Information System (INIS)

    Madeja, G.; Konieczna, S.; Gosiewska-Marcinkowska, E.; Leszek, P.

    1991-01-01

    In 15 patients with mitral valve defect and 10 patients with aortic valve defect, left ventricular end-diastolic and end-systolic volumes were determined by gated radionuclide angiography. The results were compared with contrast ventriculography. The correlation coefficient between the two methods was much lower in cases of mitral valve diseases. (author). 1 tab

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you're taking and allergies, especially ... is Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ... Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. Angiography uses ... has narrowed the arteries to the legs and help prepare for endovascular intervention or surgery. detect disease ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an ... The catheter used in angiography is a long plastic tube about as thick as a strand of ...

  3. Nopal I uranium deposit: A study of radionuclide migration

    International Nuclear Information System (INIS)

    Wong, V.; Anthony, E.; Goodell, P.

    1996-01-01

    This summary reports on activities of naturally-occurring radionuclides for the Nopal I uranium deposit located in the Pena Blanca Uranium District, Chihuahua, Mexico. Activities were determined using gamma-ray spectroscopy. In addition, data reduction procedures and sample preparation (for Rn retention) will be discussed here. Nopal I uranium deposit has been identified as one of the most promising sites for analogue studies to the proposed high-level nuclear waste repository at Yucca Mountain, Nevada. The objective of this research is to study the potential for radionuclide migration by testing whether any portion of the deposit is in secular equilibrium

  4. Nopal I uranium deposit: A study of radionuclide migration

    Energy Technology Data Exchange (ETDEWEB)

    Wong, V.; Anthony, E.; Goodell, P. [Univ. of Texas, El Paso, TX (United States)

    1996-12-01

    This summary reports on activities of naturally-occurring radionuclides for the Nopal I uranium deposit located in the Pena Blanca Uranium District, Chihuahua, Mexico. Activities were determined using gamma-ray spectroscopy. In addition, data reduction procedures and sample preparation (for Rn retention) will be discussed here. Nopal I uranium deposit has been identified as one of the most promising sites for analogue studies to the proposed high-level nuclear waste repository at Yucca Mountain, Nevada. The objective of this research is to study the potential for radionuclide migration by testing whether any portion of the deposit is in secular equilibrium.

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... lies. The catheter used in angiography is a long plastic tube about as thick as a strand of spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ...

  6. Effect of organic complexants on the mobility of low-level-waste radionuclides in soils

    International Nuclear Information System (INIS)

    Swanson, J.L.

    1982-02-01

    The effect of certain organic complexants on the distribution of some radionuclides between solution and soil has been measured. The complexants and radionuclides examined are some of those most likely to be present in low-level waste disposal sites; Cs, Sr, Ni, Co, and Eu radionuclides, and EDTA, DTPA, oxalate, and citrate complexants. The effect of complexants was found to vary widely; in some systems there was no effect and in other systems there were large effects. In some cases slow rates of reaction have not allowed equilibrium measurements to be made

  7. EFFECTIVE SPECIFIC ACTIVITY OF NATURAL RADIONUCLIDES FOR THE NORM BELONGED TO 238U AND 232TH SERIES BEING IN THE STATE OF DISTURBED RADIOACTIVE EQUILIBRIUM

    Directory of Open Access Journals (Sweden)

    I. P. Stamat

    2008-01-01

    Full Text Available In the Sanitary Rules SR 2.6.1.1292-03 and SR 2.6.6.1169-02 classification of the industrial waste containing naturally occurring radioactive materials is adopted in accordance to the values of their effective specific activity Aeff. In a case of the disturbed equilibrium in 238U and 232Th series it is necessary to take into consideration actual contribution of the separate natural radionuclides of the mentioned series into the value of gamma dose rate of the waste. This will permit to avoid unjustified overestimating or understating of the waste category which prevents as unjustified expenditures on their treating so undertaking of the necessary measures providing radiation safety.

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Interventional radiologist performing an angiography exam View ... ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored by Please note ...

  9. Abdominal MR angiography

    International Nuclear Information System (INIS)

    Wegmueller, H.; Vock, P.

    1993-01-01

    The two techniques currently most often used for MR angiography, those based on time-of-flight effects and on phase-contrast, are introduced, and our results with three-dimensional phase contrast angiography of the abdomen are presented. Several basic differences from other imaging procedures render MR angiography clinically useful for screening for renal artery stenosis in critical situations, such as renal failure or intolerance to contrast agents. In the future, the spectrum of applications of MR angiography will broaden and include other indications, such as portal venous hypertension and follow-up studies after surgical portal systemic shunting. (orig.) [de

  10. A comparative analysis of pulmonary ventilation-perfusion imaging with pulmonary angiography in the diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Wang Jincheng; Mi Hongzhi; Wang Qian; Zhang Weijun; Lu Biao; Yang Hao; Ding Jian; Lu Yao

    2001-01-01

    Objective: To assess the value of ventilation-perfusion imaging in the diagnosis of pulmonary embolism (PE). Methods: Thirty consecutive patients with clinically suspected pulmonary embolism were studied, male: female 15:15, mean age was (36.2 +- 13.9) years. The chest radiograms were obtained in all 30 patients. All patients underwent radionuclide ventilation-perfusion imaging and pulmonary angiography. Results: Of the 30 patients, 22 with lobe, multiple segment or multi-subsegment perfusion defects and normal or nearly normal ventilation images were reported as PE. 20 of them were confirmed to be with PE by pulmonary angiography, 2 patients were not confirmed. Eight of 30 patients with multiple perfusion defects, ventilative abnormalities were reported as non-PE and the diagnoses were confirmed by pulmonary angiography. The sensitivity, specificity and accuracy of diagnosis of PE by ventilation-perfusion imaging was 100%, 80.0% and 93.3% respectively. Conclusions: (1) Ventilation-perfusion imaging is one of the most valuable methods in the diagnosis of PE. (2) The results suggest that pulmonary embolism can be diagnosed non-invasively in most patients on the basis of clinical manifestation, chest radiograms and ventilation-perfusion imaging findings. (3) Pulmonary angiography is required while clinical manifestation and ventilation-perfusion imaging findings are discordant with each other

  11. A study on the radionuclide transport by bacteria in geologic media

    International Nuclear Information System (INIS)

    Han, Byoung Sub

    1997-02-01

    The purpose of this paper is to provide a methodology to develop a predictive model based on a conceptual three phase system and to investigate the influence of bacteria and their generation on the transport of radionuclide in porous and fractured media. The mass balance for bacteria, substrate and radionuclide were formulated. To illustrate the model simply, an equilibrium condition was assumed to partition the substrate, bacteria and radionuclide concentrations between the solid soil matrix, aqueous phase, rock matrix and bacterial surface. From the numerical calculation of the radionuclide transport in the presence of bacteria, it was found that the growth of bacteria and supplied primary substrate as limiting or stimulating growth factor of bacteria are the most important factors of the radionuclide transport. We also found that, depend on the transport of bacteria the temporal and spatial distribution of radionuclide concentration was significantly altered. The model proposed in this study will improve the evaluation of the role of the bacteria in the transport of radionuclide in groundwater systems. Furthermore, this model would be usefully utilized in analyzing the important role of colloidal particulate on the overall performance of radioactive waste safety

  12. Magnetic resonance angiography vs. angiography in tetralogy of Fallot.

    Science.gov (United States)

    Rao, Uppalapati Venkateswara; Vanajakshamma, Velam; Rajasekhar, Durgaprasad; Lakshmi, Amancharla Yadagiri; Reddy, Reddivari Niranjan

    2013-08-01

    : To determine whether gadolinium-enhanced three-dimensional magnetic resonance angiography can provide a noninvasive alternative to diagnostic catheterization for evaluation of pulmonary artery anatomy in tetralogy of Fallot. Thirty-five consecutive patients with tetralogy of Fallot, who attended the cardiology outpatient department between January 2008 and December 2009, were included in the study. There were 21 males and 14 females, with a mean age of 9 ± 4.15 years (range, 3-21 years). Thirty-two patients had tetralogy of Fallot with varying severities of valvular and infundibular stenosis. Three patients had tetralogy of Fallot with pulmonary atresia. All patients underwent both cardiac catheterization with X-ray angiography and 3-dimensional magnetic resonance angiography within one month. Measurements of right and left pulmonary arteries and aortopulmonary collaterals were equal by both methods. There was a good correlation between magnetic resonance angiography and catheterization measurements of branch pulmonary arteries. Gadolinium-enhanced three-dimensional magnetic resonance angiography can be used as a reliable noninvasive alternative to X-ray cineangiography for delineation of pulmonary arterial anatomy in sick infants and young children, obviating the need for catheterization.

  13. Exchange of certain radionuclides between environment and freshwater algae

    International Nuclear Information System (INIS)

    Marchyulenene, E. D.P.

    1978-01-01

    Data on the dynamics and levels of accumulation of strontium, cesium, cerium and ruthenium radionuclides by Charophyta and Cladophora fresh-water algae are presented. An attempt has been made to investigate some processes that accompany the accumulation of radionuclides by plants. Under experimental conditions, the intensity and levels of radionuclide accumulation can be presented in the following order: 144 Ce> 106 Ru> 90 Sr> 137 Cs. The dynamics of radionuclide accumulation varied greatly with the radionuclide and the algae species studied. The 144 Ce accumulation coefficients (AC) in the course of experiment (from 3 hours to 16 days) increased 8-, 9-, 23.4-, 27-, 14.3- and 20.4-fold for Cladophora glomerata, Nitella syncarpa, Nitellopsis obtusa, Chara vulgaris, Ch. rudis, and Ch. aspera, respectively. In the case of 106 Ru, AC for C.glomerata, N. syncarapa, Ch. vulgaris and Ch. rudis increased 34-, 18-,24- and 23-fold, respectively. In all algae species studied the equilibrium of radionuclide accumulation was attained after 2-4 days of experiment. Levels of accumulated 90 Sr and 137 Cs in most species depended on the season while that of 144 Cs and 106 Ru remained constant throughout the vegetation period. The levels of radionuclide elimination, like the accumulation levels, are shown to depend on both isotopes and algae species

  14. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. ...

  15. Mathematical and numerical modeling considerations for radionuclide ion migration in porous media

    International Nuclear Information System (INIS)

    Treadway, A.H.

    1984-04-01

    The equations governing radionuclide transport in sorbing, porous media are presented using phenomenological coefficients. Both equilibrium controlled and simple rate controlled chemistry are summarized. Several simplified models are discussed. Finally, various numerical problems are considered. 25 references

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... further information please consult the ACR Manual on Contrast Media and its references. The risk of serious allergic ... View full size with caption Related Articles and Media Angioplasty and Vascular Stenting MR Angiography (MRA) Contrast Materials CT Angiography (CTA) X-ray, Interventional Radiology ...

  17. Radioactive waste-Portland cement systems: I, radionuclide distribution

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Glasser, F.P.; Lachowski, E.E.

    1984-01-01

    Crystal chemical stabilization of radioactive wastes can be achieved during clinkering of, or with, ordinary portland cement. Waste loadings of 20 to 30 wt% are achieved by dilute solid solution of waste ions into cementitious host lattices. Higher waste loadings result in compatible noncementitious radiophases. The cementitious phases hydrate without loss of compressive strength. Crystallochemical relationships predict that the radionuclide partitioning in the anhydrous clinkered phases will be maintained in the hydration products. These cementitious hydroxylated radiophases would be in internal equilibrium under anticipated repository conditions. The radionuclide distributions observed are described in the context of established phase equilibria for commercial waste cement systems, but are applicable to transuranic, medium- and low-level wastes

  18. Methods for determining radionuclide retardation factors: status report

    International Nuclear Information System (INIS)

    Relyea, J.F.; Serne, R.J.; Rai, D.

    1980-04-01

    This report identifies a number of mechanisms that retard radionuclide migration, and describes the static and dynamic methods that are used to study such retardation phenomena. Both static and dynamic methods are needed for reliable safety assessments of underground nuclear-waste repositories. This report also evaluates the extent to which the two methods may be used to diagnose radionuclide migration through various types of geologic media, among them unconsolidated, crushed, intact, and fractured rocks. Adsorption is one mechanism that can control radionuclide concentrations in solution and therefore impede radionuclide migration. Other mechanisms that control a solution's radionuclide concentration and radionuclide migration are precipitation of hydroxides and oxides, oxidation-reduction reactions, and the formation of minerals that might include the radionuclide as a structural element. The retardation mechanisms mentioned above are controlled by such factors as surface area, cation exchange capacity, solution pH, chemical composition of the rock and of the solution, oxidation-reduction potential, and radionuclide concentration. Rocks and ground waters used in determining retardation factors should represent the expected equilibrium conditions in the geologic system under investigation. Static test methods can be used to rapidly screen the effects of the factors mentioned above. Dynamic (or column) testing, is needed to assess the effects of hydrodynamics and the interaction of hydrodynamics with the other important parameters. This paper proposes both a standard method for conducting batch Kd determinations, and a standard format for organizing and reporting data. Dynamic testing methods are not presently developed to the point that a standard methodology can be proposed. Normal procedures are outlined for column experimentation and the data that are needed to analyze a column experiment are identified

  19. Detection of aneurysms in subarachnoidal hemorrhage - CT-angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Roehnert, W.; Haenig, V.; Hietschold, V.; Abolmaali, N.

    1998-01-01

    Purpose: The value of CT-angiography (CT-A) for the visualization of intracranial aneurysms was more closely defined by comparison with digital subtraction angiography (DSA). Methods: Over a period of 18 months a total of 106 patients in whom a subarachnoidal hemorrhage had been detected on native CT were examined in parallel by spiral CT and DSA. CT-angiography was performed under standardized parameters and included processing with 3D surface reconstructions. Results: In 64 patients (60.4%) at total of 72 aneurysms were detected. In four cases (6.2%) there were two and in two cases (3.1%) even three aneurysms. The findings of DSA and CTA agreed in 98 cases (92.5%). In four patients (3.8%) a false negative results was obtained in CTA and the initial DSA. Conclusions: Digital subtraction angiography must still be considered as the gold standard in the diagnosis of cerebral aneurysms. On account of its excellent spatial delineation of aneurysms and possibilities for exact measurements, CT-angiography represents a valuable, supplementary method - in some cases also an alternative method - to digital subtraction angiography. (orig.) [de

  20. CASCADER: An M-chain gas-phase radionuclide transport and fate model

    International Nuclear Information System (INIS)

    Lindstrom, F.T.; Cawlfield, D.E.; Emer, D.F.; Shott, G.J.; Donahue, M.E.

    1993-02-01

    Chemicals and radionuclides move either in the gas-phase, liquid-phase, or both phases in soils. They may be acted upon by either biological or abiotic processes through advection and diffusion. Furthermore, parent and daughter radionuclides may decay as they are transported in the soil. CASCADER is a gas-phase, one-space dimensional transport and fate model for M-chain radionuclides in very dry homogeneous or heterogeneous soil. This model contains barometric pressure-induced advection and diffusion together with linear irreversible and linear reversible sorption for each radionuclide. The advection velocity is derived from an embedded air-pumping submodel. The air-pumping submodel is based on an assumption of isothermal conditions, which is driven by barometric pressure. CASCADER allows the concentration of source radionuclides to decay via the classical Bateman chain of simple, first-order kinetic processes. The transported radionuclides also decay via first-order processes while in the soil. A mass conserving, flux-type inlet and exit set of boundary conditions are used. The user must supply the initial distribution for the parent radionuclide in the soil. The initial daughter distribution is found using equilibrium rules. The model is user friendly as it uses a prompt-driven, free-form input. The code is ANSI standard Fortran 77

  1. CASCADER: An m-chain gas-phase radionuclide transport and fate model

    International Nuclear Information System (INIS)

    Lindstrom, F.T.; Cawlfield, D.E.; Emer, D.F.; Shott, G.J.; Donahue, M.E.

    1992-06-01

    Chemicals and radionuclides move either in the gas-phase, liquid-phase, or both phases in soils. They may be acted upon by either biological or abiotic processes as they are advected and/or dispersed. Furthermore, parent and daughter radionuclides may decay as they are transported in the soil. CASCADER is a gas-phase, one space dimensional transport and fate model for an m-chain of radionuclides in very dry soil. This model contains barometric pressure-induced advection and diffusion together with linear irreversible and linear reversible sorption for each radionuclide. The advocation velocity is derived from an embedded air-pumping submodel. The airpumping submodel is based on an assumption of isothermal conditions and is barometric pressure driven. CASCADER allows the concentration of source radionuclides to decay via the classical Bateman chain of simple, first-order kinetic processes. The transported radionuclides also decay via first-order processes while in the soil. A mass conserving, flux-type inlet and exit set of boundary conditions is used. The user must supply the initial distribution for the parent radionuclide in the soil. The initial daughter distribution is found using equilibrium rules. The model is user friendly as it uses a prompt-driven, free-form input. The code is ANSI standard Fortran 77

  2. Intracranial MR angiography

    International Nuclear Information System (INIS)

    Davis, W.L.; Blatter, D.D.; Parker, D.L.; Robison, R.O.; Harnsberger, H.R.

    1991-01-01

    This paper compares the more traditional three-dimensional (3D) time-of-flight MR angiography with a novel new technique, MOTSA, in the evaluation of both normal and abnormal intracranial anatomy. The authors performed sequential, location-matched 3D TOF and MOTSA MR angiography in 10 subjects with normal and 25 with abnormal intracranial anatomy. Images were evaluated for visualization of specific vessels and depiction of pathologic anatomy. All images were subjected to an objective scoring system. Digital angiography was available in 15 of 25 abnormal cases. In the normal cases, large- and small-vessel visualization was improved. Significant improvement in visualization of venous anatomy was also observed. In the abnormal cases, pathologic anatomy was better visualized, providing important diagnostic information. Multiple overlapping thin-slab-acquisition MR angiography demonstrates vessel visualization that is increased over that of 3D TOF MR angiography in both normal and abnormal cases. Because of the decrease in saturation effects and phase dispersion, MOTSA is especially useful in the evaluation of complex intracranial vascular abnormalities

  3. Transfer of radionuclides to animal products following ingestion or inhalation

    International Nuclear Information System (INIS)

    Coughtrey, P.J.

    1996-01-01

    Contamination of animal products forms an important pathway in the transfer of radionuclides from source to man. Simulation of radionuclide transfer via animal products requires an understanding of the processes and mechanisms involved in absorption, distribution, turnover and excretion of radionuclides and related elements in animals as well as knowledge of animal grazing habits and husbandry. This paper provides a summary of the metabolism of important radionuclides in typical domestic animals and of the mathematical approaches that have been used to simulate transfer from diet to animal product. The equilibrium transfer factor approach has been used widely but suffers a number of disadvantages when releases or intakes are variable with time or when intakes are short relative to the lifetime of the animal of interest. Dynamic models, especially those of the compartmental type, have been developed and used widely. Both approaches have benefited from experiences obtained after the Chernobyl accident but a number of uncertainties still exist. Whereas there is now extensive knowledge on the behaviour of radiocaesium in both domestic and wild animals, knowledge of the behaviour of other potentially important radionuclides remains limited. Further experimental and metabolic studies will be required to reduce uncertainties associated with the transfer of radionuclides other than radiocaesium and thereby produce a sound basis for radiological assessments. (author)

  4. Rest and exercise radionuclide ventriculography in the ambulatory monitoring of patients with valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Raichlen, J.S.; Brest, A.N.

    1988-01-01

    Radionuclide angiography serves as a valuable adjunct in the noninvasive evaluation and monitoring of patients with valvular heart disease. Although estimations of regurgitant fractions and the differences between left and right ventricular stroke volumes can be made, the limitations of the techniques do not enable adequate quantitation of the severity of valvular insufficiency to warrant routine use in ambulatory management. The importance of radionuclide ventriculography, however, lies in its ability to examine global ventricular function both at rest and with exercise, thus enabling assessment of the functional reserve of the left and right ventricles. Such data are of considerable value in determining the need for invasive evaluation and the timing of valve replacement in patients with valvular heart disease. 41 references.

  5. Rest and exercise radionuclide ventriculography in the ambulatory monitoring of patients with valvular heart disease

    International Nuclear Information System (INIS)

    Raichlen, J.S.; Brest, A.N.

    1988-01-01

    Radionuclide angiography serves as a valuable adjunct in the noninvasive evaluation and monitoring of patients with valvular heart disease. Although estimations of regurgitant fractions and the differences between left and right ventricular stroke volumes can be made, the limitations of the techniques do not enable adequate quantitation of the severity of valvular insufficiency to warrant routine use in ambulatory management. The importance of radionuclide ventriculography, however, lies in its ability to examine global ventricular function both at rest and with exercise, thus enabling assessment of the functional reserve of the left and right ventricles. Such data are of considerable value in determining the need for invasive evaluation and the timing of valve replacement in patients with valvular heart disease. 41 references

  6. Erosion of atmospherically deposited radionuclides as affected by soil disaggregation mechanisms

    International Nuclear Information System (INIS)

    Claval, D.; Garcia-Sanchez, L.; Real, J.; Rouxel, R.; Mauger, S.; Sellier, L.

    2004-01-01

    The interactions of soil disaggregation with radionuclide erosion were studied under controlled conditions in the laboratory on samples from a loamy silty-sandy soil. The fate of 134 Cs and 85 Sr was monitored on soil aggregates and on small plots, with time resolution ranging from minutes to hours after contamination. Analytical experiments reproducing disaggregation mechanisms on aggregates showed that disaggregation controls both erosion and sorption. Compared to differential swelling, air explosion mobilized the most by producing finer particles and increasing five-fold sorption. For all the mechanisms studied, a significant part of the contamination was still unsorbed on the aggregates after an hour. Global experiments on contaminated sloping plots submitted to artificial rainfalls showed radionuclide erosion fluctuations and their origin. Wet radionuclide deposition increased short-term erosion by 50% compared to dry deposition. A developed soil crust when contaminated decreased radionuclide erosion by a factor 2 compared to other initial soil states. These erosion fluctuations were more significant for 134 Cs than 85 Sr, known to have better affinity to soil matrix. These findings confirm the role of disaggregation on radionuclide erosion. Our data support a conceptual model of radionuclide erosion at the small plot scale in two steps: (1) radionuclide non-equilibrium sorption on mobile particles, resulting from simultaneous sorption and disaggregation during wet deposition and (2) later radionuclide transport by runoff with suspended matter

  7. Coronary angiography using synchrotron radiation

    International Nuclear Information System (INIS)

    Akatsuka, Takao; Hiranaka, Yukio; Takeda, Tohru; Hyodo, Kazuyuki.

    1990-01-01

    Invasive coronary angiography is the imaging technique of choice for diagnosis of ischemic heart disease. Recently, the application of synchrotron radiation in coronary angiography has been investigated in the world, with the aim of developing the noninvasive technique for visualizing the heart. In this article, backgrounds and present situation of coronary angiography using synchrotron radiation are reviewed. Firstly, visual imaging techniques of the cardiovascular system are discussed in terms of angiography and digital subtraction angiography (DSA). Conventional temporal, energy, and hybrid subtraction modes used in DSA are referred to. Secondly, the application of synchrotron radiation is presented, focusing on the property of synchrotron radiation and K-edge subtraction angiography. Two kinds of synchrotron radiation beam methods are outlined. Interpretation of image data and various subtraction procedures remain unestablished. There is much to be done before coronary angiography using synchrotron radiation comes into a clinical practice. (N.K.)

  8. Effect of diltiazem on myocardial infarct size estimated by enzyme release, serial thallium-201 single-photon emission computed tomography and radionuclide angiography

    International Nuclear Information System (INIS)

    Zannad, F.; Amor, M.; Karcher, G.; Maurin, P.; Ethevenot, G.; Sebag, C.; Bertrand, A.; Pernot, C.; Gilgenkrantz, J.M.

    1988-01-01

    Diltiazem is a calcium antagonist with demonstrated experimental cardioprotective effects. Its effects on myocardial infarct size were studied in 34 patients admitted within 6 hours after the first symptoms of acute myocardial infarction. These patients were randomized, double-blind to placebo or diltiazem (10-mg intravenous bolus followed by 15 mg/hr intravenous infusion during 72 hours, followed by 4 X 60 mg during 21 days). Myocardial infarct size was assessed by plasma creatine kinase and creatine kinase-MB indexes, perfusion defect scores using single-photon emission computed tomography with thallium-201 and left ventricular ejection fraction measured by radionuclide angiography. Tomographic and angiographic scanning was performed serially before randomization, after 48 hours and 21 days later. Groups were comparable in terms of age, sex, inclusion time and baseline infarct location and size. Results showed no difference in creatine kinase and creatine kinase-MB data between controls and treated patients, a significant decrease in the perfusion defect scores in the diltiazem group (+0.1 +/- 3.0 placebo vs -2.2 +/- 1.9 diltiazem, p less than 0.02) and a better ejection fraction recovery in the diltiazem group (-4.2 +/- 7.4 placebo vs +7.7 +/- 11.2 diltiazem, p less than 0.05). Myocardial infarct size estimates from perfusion defect scores and enzyme data were closely correlated. These preliminary results suggest that diltiazem may reduce ischemic injury in acute myocardial infarction

  9. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  10. An international database of radionuclide concentration ratios for wildlife: development and uses.

    Science.gov (United States)

    Copplestone, D; Beresford, N A; Brown, J E; Yankovich, T

    2013-12-01

    A key element of most systems for assessing the impact of radionuclides on the environment is a means to estimate the transfer of radionuclides to organisms. To facilitate this, an international wildlife transfer database has been developed to provide an online, searchable compilation of transfer parameters in the form of equilibrium-based whole-organism to media concentration ratios. This paper describes the derivation of the wildlife transfer database, the key data sources it contains and highlights the applications for the data. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Angiography in angiology

    International Nuclear Information System (INIS)

    Zeitler, E.; Grosse-Vorholt, R.

    1980-01-01

    A review is given of recent developments in angiography including advances in the equipment, in the technique and in image processing. Indications for and interpretation of angiography are discussed and angiographic-therapeutic procedures are considered. (C.F.)

  12. Compromised Cerebral Blood Flow(CBF) in Congestive Heart Failure (CHB): non-invasive quantification with {sup 99m}Tc-ECD radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Seung; Kim, Jae Joong; Lim, Ki Chun; Lee, Hee Kyung; Moon, Dae Hyuk [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2002-07-01

    Recent reports revealed that cerebral metabolism in CHF was abnormally deranged and proposed as a potential marker of disease severity. Since deranged cerebral metabolism in CHF may result from compromised cerebral perfusion, quantification of CHF may be useful for accurate risk stratification of CHF. Therefore, we investigated whether CHF in patients with CHF is compromised and correlated with clinical parameters. Fifteen patients (M/F:11/5, 45{+-}9yr) with CHF (LVEF<40%) and 7 healthy controls (M/F:5/2, 41{+-}8yr) were prospectively studied. All patients underwent radionuclide angiography including cerebral hemispheres and aortic arch using {sup 99m}Tc-ECD. Global CBF was measured non-invasively by the application of Patlak graphical plot analysis. All patients were also evaluated using a standardized protocol that included echocardiography and clinical evaluation. Global CBF (40.3{+-}5.2 ml/min/100g) of the patients with CHF were significantly lower than those (49.7{+-}2.4 ml/min/100g) of controls (p<0.01). Global CBF were correlated with NYHA functional class (r=-0.617, p=0.43), but not correlated with other clinical parameters such as age (r=-0.463, p=0.082), duration (r=0.237, p>0.1), systolic BP (r=-0.063, p>0.5), LVEF (r=-0.13, p>0.1), LV dimension(r=0.139, p>0.5), and PV pressure gradients (r=0.072, p>0.5). Cerebral perfusion of the patients with CHF was compromised and not correlated with cardiopulmonary hemodynamic parameters.

  13. The effect of bacterial generation on the transport of radionuclide in porous media

    International Nuclear Information System (INIS)

    Han, B.S.; Lee, K.J.

    1997-01-01

    The purpose of this paper is to provide a methodology to develop a predictive model based on a conceptual three-phase system and to investigate the influence of bacteria and their generation on the radionuclide transport in porous media. The mass balance equations for bacteria, substrate and radionuclide were formulated. To illustrate the model simply, an equilibrium condition was assumed to partition the substrate, bacteria and radionuclide concentrations, between the solid soil matrix, aqueous phase and bacterial surface. From the numerical calculation of radionuclide transport in the presence of bacteria, it was found that the growth of bacterial and supplied primary substrate as a limiting or stimulating growth factor of bacteria are the most important factors of the radionuclide transport. It was also found that, depending on the transport of bacteria, the temporal and spatial distribution of the radionuclide concentration was significantly affected. The model proposed in this study will improve the evaluation of the role of the bacteria to the transport of radionuclide in groundwater systems. Furthermore, this model can be usefully utilized in analyzing the important role of colloidal particulate on the overall performance of radioactive waste safety. (Author)

  14. Haw-glass dissolution and radionuclide release: mechanism - modelling - source term

    Energy Technology Data Exchange (ETDEWEB)

    Grambow, B [Forschungszentrum Karlsruhe, Institut fur Nukleare, Karlsruhe (Germany)

    1997-07-01

    Important release controlling processes are: 1) kinetics of glass matrix dissolution (leaching), 2) formation of secondary alteration products (controlling thermodynamic solubility), 3) sorption on surfaces in the engineered barrier system and 4) formation of mobile species. Quantification of these processes requires assessment of the energetics and dynamics of the various reversible and irreversible processes within an overall open non-equilibrium system. Corrosion/dissolution of the waste matrices is not necessarily associated with a proportional release of radionuclides. The formation of new secondary phases, such as silicates, molybdates, uranates, carbonates... establishes a new geochemical barrier for re-immobilization of radionuclides dissolved from the waste matrices. The presence of iron (corroding canisters during glass alteration) reduces the solution concentration of redox sensitive radionuclides. Consequently, the container, after being corroded, constitutes an important geochemical barrier for radionuclide re-immobilization. Geochemical modelling of the long-term behaviour of glasses must be performed in an integrated way, considering simultaneous reactions of the glass, of container corrosion, of repository rock and of backfill material. Until now, only few attempts were made for integral systems modelling. (A.C.)

  15. Radionuclide methods of identifying patients who may require coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Beller, G.A.; Gibson, R.S.; Watson, D.D.

    1985-01-01

    Myocardial thallium-201 ( 201 Tl) scintigraphy or radionuclide angiography performed in conjunction with exercise stress testing can provide clinically useful information regarding the functional significance of underlying coronary artery stenoses in patients with known or suspected coronary artery disease. Knowledge of type, location, and extent of myocardial 201 Tl perfusion abnormalities or the severity of exercise-induced global and regional dysfunction has prognostic value. Risk stratification can be undertaken with either radionuclide technique by consideration of the magnitude of the ischemic response and may assist in the selection of patients for coronary artery bypass graft surgery (CABG). In patients with coronary artery disease, delayed 201 Tl redistribution observed on exercise or dipyridamole 201 Tl scintigraphy, particularly when present in multiple vascular regions and associated with increased lung 201 Tl uptake, has been shown to be predictive of an adverse outcome, whereas patients with chest pain and a normal exercise 201 Tl scintigram have a good prognosis with medical treatment. Similarly, a marked fall in the radionuclide ejection fraction from rest to exercise has been found to correlate with high-risk anatomic disease. Another important application of radionuclide imaging in patients being considered for CABG (particularly those with a depressed resting left ventricular ejection fraction) is the determination of myocardial viability and potential for improved blood flow and enhanced regional function after revascularization. 69 references

  16. Prognostic significance of radionuclide-assessed diastolic function in hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Chikamori, T.; Dickie, S.; Poloniecki, J.D.; Myers, M.J.; Lavender, J.P.; McKenna, W.J.

    1990-01-01

    To evaluate the prognostic significance of diastolic function in hypertrophic cardiomyopathy (HC), technetium-99m gated equilibrium radionuclide angiography, acquired in list mode, was performed in 161 patients. Five diastolic indexes were calculated. During 3.0 +/- 1.9 years, 13 patients had disease-related deaths. With univariate analysis, these patients were younger (29 +/- 20 vs 42 +/- 16 years; p less than 0.05), had a higher incidence of syncope (p less than 0.025), dyspnea (p less than 0.001), reduced peak filling rate (2.9 +/- 0.9 vs 3.4 +/- 1.0 end-diastolic volume/s; p = 0.09) with increased relative filling volume during the rapid filling period (80 +/- 7 vs 75 +/- 12%; p = 0.06) and decreased atrial contribution (17 +/- 7 vs 22 +/- 11%; p = 0.07). Stepwise discriminant analysis revealed that young age at diagnosis, syncope at diagnosis, reduced peak ejection rate, positive family history, reduced peak filling rate, increased relative filling volume by peak filling rate and concentric left ventricular hypertrophy were the most statistically significant (p = 0.0001) predictors of disease-related death (sensitivity 92%, specificity 76%, accuracy 77%, positive predictive value 25%). Discriminant analysis excluding the diastolic indexes, however, showed similar predictability (sensitivity 92%, specificity 76%, accuracy 78%, positive predictive value 26%). To obtain more homogeneous groups for analysis, patients were classified as survivors or electrically unstable, including sudden death, out-of-hospital ventricular fibrillation and nonsustained ventricular tachycardia during 48-hour ambulatory electrocardiography, and heart failure death or cardiac transplant

  17. Intravenous digital subtraction angiography in the assessment of patients with left to right shunts before and after surgical correction

    International Nuclear Information System (INIS)

    Yiannikas, J.; Moodie, D.S.; Gill, C.C.; Sterba, R.; McIntyre, R.; Buonocore, E.

    1984-01-01

    Pre- and postoperative structural changes and pulmonary to systemic flow (QP/QS) ratios were assessed using digital angiography in 34 patients documented to have a left to right shunt at cardiac catheterization. There were 16 men and 18 women whose ages ranged from 4 months to 60 years. The radiographic single mask mode was used for all digital subtraction angiographic studies with a typical radiographic sequence being 80 to 100 kV, 5 to 10 mA/frame at six frames/s for 15 seconds. Renografin-76 was used as a bolus injection at 0.5 to 1.0 ml/kg via an arm vein in most patients. The level of the left to right shunt and any associated anomalies were noted and compared with results from cardiac catheterization. Digital subtraction angiographic flow curves were generated from the pulmonary arteries, and QP/QS ratios were calculated pre- and postoperatively using the gamma variate fit method and compared with the QP/QS ratio from first pass radionuclide studies. A strong correlation between preoperative digital subtraction angiographically derived QP/QS ratio and radionuclide-derived QP/QS ratio was found, with an r value equal to 0.89, p less than 0.0001. Postoperatively, all patients had a QP/QS ratio less than 1.2:1.0 for both digital subtraction angiography and radionuclide studies. The level of left to right shunt was accurately assessed in all patients, and its absence observed postoperatively. Associated anomalies, such as a persistent left superior vena cava, coarctation of the aorta and partial anomalous venous return, were identified in all cases

  18. The dynamics of radionuclide behaviour in soil solution with special reference to the application of countermeasures

    International Nuclear Information System (INIS)

    Nisbet, A.F.; Lembrechts, J.F.

    1990-01-01

    Any investigations into the effect of countermeasures on radionuclide transfer to plants should include a comprehensive chemical analysis of soil solution. This is because of the disturbances that soil-based countermeasures cause on soil:solution equilibria and radionuclide distribution between solid and liquid phases. As it is difficult to determine directly the effects of countermeasures under field conditions, it is recommended that laboratory-based studies be done first. These should include batch equilibrium experiments for soil:solution interactions, and hydroponic studies for solution:plant relationships. Speciation of radionuclides should form a fundamental part of both studies. (author)

  19. Diagnostic yield and accuracy of CT angiography, MR angiography, and digital subtraction angiography for detection of macrovascular causes of intracerebral haemorrhage: Prospective, multicentre cohort study

    NARCIS (Netherlands)

    C.J.J. Van Asch (Charlotte J.J.); B.K. Velthuis (Birgitta K.); G.J.E. Rinkel (Gabriël J.E.); A. Algra (Ale); G.A.P. de Kort (G. A P); T.D. Witkamp (Theo); J.C.M. De Ridder (Johanna C.M.); K.M. Van Nieuwenhuizen (Koen M.); F.-E. De Leeuw (Frank-Erik); W.J. Schonewille (Wouter); P.L.M. de Kort (Paul); D.W.J. Dippel (Diederik); T.W.M. Raaymakers (Theodora W.M.); J. Hofmeijer; M.J.H. Wermer (Marieke); H. Kerkhoff (Henk); K. Jellema (Korné); I.M. Bronner (Irene M.); M.J.M. Remmers (Michel ); H.P. Bienfait (Henri); R.J.G.M. Witjes (Ron J.G.M.); J.P. Greving (Jacoba); C.J.M. Klijn (Catharina J.M.); H.F. de Leeuw (Frank); H.B. Boogaarts; E.J. van Dijk (Ewoud); W.J. Schonewille; W.M.J. Pellikaan; C. Puppels-De Waard; P.L.M. De Kort; J.P. Peluso; J. van Tuijl (Jordie); J. Hofmeijer; F.B.M. Joosten (Frank); D.W.J. Dippel (Diederik); L. Khajeh (Ladbon); T.W.M. Raaijmakers; M.J. Wermer; M.A.A. van Walderveen (Marianne); H. Kerkhoff; E. Zock; K. Jellema (Korné); G.J. Lycklama à Nijeholt (Geert); I.M. Bronner; M.J.M. Remmers; R.J.G.M. Witjes; H.P. Bienfait; K.E. Droogh-Greve; R. Donders (Rogier); V.I.H. Kwa; T.H.C.M.L. Schreuder (Tobien H. C. M. L.); C.L. Franke (Cees); J.S. Straver; C. Jansen; S.L.M. Bakker (Stef); C.C. Pleiter (C.); M.C. Visser; C.J.J. Van Asch; B.K. Velthuis (Birgitta); G.J.E. Rinkel (Gabriel); K.M. Van Nieuwenhuizen; C.J.M. Klijn (Catharina J.M.)

    2015-01-01

    textabstractStudy question What are the diagnostic yield and accuracy of early computed tomography (CT) angiography followed by magnetic resonance imaging/angiography (MRI/MRA) and digital subtraction angiography (DSA) in patients with non-traumatic intracerebral haemorrhage? Methods This

  20. Kinetic approach for interactive reactions of radionuclide, bacteria and granitic crushed rock

    International Nuclear Information System (INIS)

    Kim, Jung Woo; Baik, Min Hoon; Lee, Seung Yeop; Lee, Jae Kwang; Kim, Seung Soo; Oh, Jong Min; Lee, Tae Yup

    2011-01-01

    For many radionuclides, sorption is an important phenomenon as their migration rates in groundwater are reduced in both engineered barrier and fractured rock matrix. Sorption of radionuclides is strongly dependent on the chemistry of the surrounding groundwater, such as pH, Eh, ionic strength, etc., by changing their valence states (e.g.,). In addition, it is also known that some bacteria can change the mobility and speciation of a radionuclide in groundwater. Biological immobilization mechanisms of radionuclides include precipitation, transformation to less soluble forms and so on. On the other hand, bacteria can also play a role of sorbent for radionuclides. Since bacteria can not only be mobile as a colloid but also be immobile as biofilm in the rock fracture, the bacteria as the sorbents of radionuclides in the groundwater can have both positive and negative effects on the radionuclide migration. In this study, therefore, sorption of radionuclide onto rock surface in the presence of bacteria was investigated via batch experiments. Although sorption equilibrium state can be expected in the transport of weakly sorbing (distribution coefficient, K d -3 m 3 kg -1 ) or strongly adsorbing (K d > ∼4.6 m 3 kg -1 ) nuclides in fractured rock, sorption kinetics needs to be considered in the intermediate range. Therefore, the sorption of radionuclide whose valence state is expected to be changed by biological reduction was evaluated in a kinetic approach

  1. Colloidal nature of radionuclides in seawater

    International Nuclear Information System (INIS)

    Feldman, I.

    1976-01-01

    There is considerable doubt that equilibrium calculations, i.e., employing solubility products and complex-ion stability constants, are valid for the submicro concentrations of radionuclides in seawater. The existence of radiocolloids should be expected in seawater. The great tendency of radiocolloids to adsorb onto finely-divided hydrous oxides makes their formation of significance in seawater, especially for artificial radionuclides. The subject of radiocolloid formation is reviewed in this chapter. It is shown that the 226 Ra/ 230 Th/U relationship found in seawater can be explained from the fact that the tendencies of these elements to form radiocolloids in seawater should decrease in order thorium > radium much greater than uranium. This explanation is much simpler than the prevailing oceanographic one. The theories for radiocolloid formation are discussed. The recent theory of Jones and Healy for the adsorption of hydrolyzable metal ions onto hydrous oxides is reviewed briefly, and its relevance to radiocolloid formation is pointed out

  2. Techniques for rapid determination of effects of synergy between radionuclides and pollutants

    International Nuclear Information System (INIS)

    Saas, A.; Grauby, A.

    1975-01-01

    The authors present a number of chromatographic techniques for rapid determination of synergy between radionuclides and various compounds in water. The first technique consists in studying how the chemical equilibrium of iodine varies in the presence of various organic and mineral compounds. The second makes it possible to define the effects of synergy within a given hydrographic basin. A third technique deals with the effects of synergy in ground water in the presence of various types of irrigation water. Finally, to complete this set of techniques, the authors define the mobility potential of a radionuclide in a given aqueous effluent

  3. Angiography - interventional diagnostic applications

    International Nuclear Information System (INIS)

    Schild, H.

    1994-01-01

    The angiography system is very different from the other systems used in diagnostic radiology. The invasivity of angiography requires special, high standards in theoretical and practical training and experience both of beginners and experienced personnel. This textbook fully meets the demand for in-depth and exhaustive information, as it presents: - The fundamentals and techniques of angiography, the vascular anatomy, and many hints and tips of great help in practice. - A comprehensive survey of diagnostic problems and examination approaches, including neuro-angiography, with 221 reproductions of original angiographs, and additional schematic representations. - A special chapter devoted to indication and relevant techniques for the major vascular interventional examinations. - A great number of tables explain at a glance standard examination techniques, indications and diagnostic criteria. (orig./CB) [de

  4. MR angiography with Vasovist

    Energy Technology Data Exchange (ETDEWEB)

    Goyen, Mathias [University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20251 Hamburg (Germany)], E-mail: goyen@uke.uni-hamburg.de

    2007-12-15

    Vasovist (Gadofosveset) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. This blood pool contrast agent reversibly binds to albumin providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive clinical and pre-clinical testing to evaluate the safety and efficacy of the drug. The clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (aorto-iliac, renal, pedal), examination of potential drug interaction with warfarin, and comparison with X-ray angiography. The clinical trials show that Vasovist-enhanced MR angiography is safe and well tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. This review article highlights the product characteristics of Vasovist, gives an overview of the clinical development program and discusses selected clinical applications.

  5. MR angiography with Vasovist

    International Nuclear Information System (INIS)

    Goyen, Mathias

    2007-01-01

    Vasovist (Gadofosveset) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. This blood pool contrast agent reversibly binds to albumin providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive clinical and pre-clinical testing to evaluate the safety and efficacy of the drug. The clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (aorto-iliac, renal, pedal), examination of potential drug interaction with warfarin, and comparison with X-ray angiography. The clinical trials show that Vasovist-enhanced MR angiography is safe and well tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. This review article highlights the product characteristics of Vasovist, gives an overview of the clinical development program and discusses selected clinical applications

  6. Application and validation of predictive computer programs describing the chemistry of radionuclides in the geosphere

    International Nuclear Information System (INIS)

    Waters, M.; Duffield, J.R.; Griffiths, P.J.F.; Williams, D.R.

    1991-01-01

    Chemval is an international project concerned with improving the data used to model the speciation chemistry of radionuclide migration from underground waste disposal sites. Chemval has two main aims: to produce a reliable database of thermodynamic equilibrium constants for use in such chemical modelling; to perform a series of test-case modelling exercises based upon real site and field data to verify and validate the existing tools used for simulating the chemical speciation and the transport of radionuclides in the environment

  7. Effect of recombinant tissue-type plasminogen activator on acute myocardial infarction; Limitation of infarct size and preservation of left ventricular function evaluated by radionuclide methods

    Energy Technology Data Exchange (ETDEWEB)

    Fukuyama, Takaya; Inou, Tetsuji; Ashihara, Toshiaki; Ogata, Ikuo; Nabeyama, Shouzou; Yamada, Akira; Murakami, Satoshi; Kodama, Mayuko; Matsui, Kanji (Matsuyama Red Cross Hospital, Ehime (Japan))

    1989-12-01

    Radionuclide studies were performed in 18 patients with acute myocardial infarction receiving i.v. injection of recombinant tissue-type plasminogen activator (rt-PA) within 12 hr after an attack. Thallium-201 single photon emission computed tomography revealed that infarct size decreased by 42% in the rt-PA treated group, as compared with 25% in the control group. Left ventricular ejection fraction, as found on first-pass radionuclide angiography with Tc-99m PYP, was significantly higher in the rt-PA treated group than the control group (49% vs 38%). Radionuclide imagings were helpful in confirming myocardial salvage after rt-PA intravenous therapy. It was also considered necessary to perform rt-PA therapy as early as possible after an acute myocardial attack. (N.K.).

  8. Diagnostic impact of anterior segment angiography of limbal stem cell insufficiency in PAX6-related aniridia.

    Science.gov (United States)

    Käsmann-Kellner, Barbara; Latta, Lorenz; Fries, Fabian N; Viestenz, Arne; Seitz, Berthold

    2018-04-01

    PAX6 is a master gene of ocular development and postnatal ocular equilibrium. Congenital aniridia is the hallmark of PAX6 gene haploinsufficiency (Chr. 11 p. 13), but PAX6-associated aniridia is a profound, progressive pan-ocular developmental disorder often leading to blindness. There is congenital visual impairment with advancing loss of vision mainly due to secondary glaucoma and to corneal blindness caused by limbal stem cell insufficiency (LSCI). LSCI leads to ARK (aniridia-related keratopathy), which typically develops in four stages. Incipient LSCI with vessels starting to grow into the cornea can be imaged by fluorescein anterior segment angiography, which enables fine vessels to be more easily detected than by routine slit lamp examination, especially in patients with nystagmus. Thus, clinical stage 1 ARK is often diagnosed at stage 2 by angiography. Corneal neovascularizations often start at the 12 and 6 positions and subsequently progress circumferentially, not at the 3 and 9 positions as previously believed. Anterior segment angiography can provide an easily standardizable tool for monitoring progress, treatment-induced regress or stabilization of ARK. Especially in children, angiography could be used to monitor new treatment regimens for reducing LSCI. Angiography could enable treatment to begin earlier to preserve corneal hemostasis. In addition, the fact that vascularization often starts at the subpalpebral 6 and 12 positions as opposed to the 3 and 9 positions raises more questions concerning factors that promote LSCI and related corneal injuries. Clin. Anat. 31:392-397, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  9. Evaluation of the pedal artery: comparison of three-dimensional gadolinium-enhanced MR angiography with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Kang, Sung Gwon; Byun, Joo Nam; Kim, Young Cheol; Choi, Jeong Yeol; Kim, Dong Hyun [College of Medicine, Chosun Univ., Kwangju (Korea, Republic of)

    2002-07-01

    To compare the three-dimensional gadolinium-enhanced MR angiography with digital subtraction angiography (DSA) for evaluation of the pedal artery. In 12 extremities of 11 patients, both digital subtraction angiography (DSA) and contrast-enhanced MR angiography (CE-MR angiography) were performed during the same week. Among ten of the 11 patients, the following conditions were present: atherosclerosis (n=4), diabetic foot (n=3), Buerger's disease (n=1), calciphylactic arteriopathy (n=1) and arteriovenous malformation of the foot (n=1). The remaining patient underwent angiography prior to flap surgery. For MR angiography, a 1.5T system using an extremity or head coil was used. A three-dimensional FISP (fast imaging with steady state precession) sequence was obtained before enhancement, followed by four sequential acquisitions (scan time, 20 secs, scan interval time, 10 secs) 10 seconds after intravenous bolus injection of normal saline (total 10 cc), following intravenous administration of gadolinium (0.02 mmol/kg, 3 ml/sec). Arterial segments of the ankle and foot were classified as the anterior or posterior tibial artery, the distal peroneal artery, the medial or lateral plantar artery, the pedal arch, and the dorsalis pedis artery. Two radiologists independently analysed visualization of each arteraial segment and the mean of visible arterial segments in one extreminty using CE-MR angiography and DSA. Among 84 arterial segments, 16 were invisible at both CE-MR angiography and DSA, while 39 were demonstrated by both modalities. Twenty-six segments were visible only at CE-MR angiography and three only at DSA. CE-MR angiography displayed a higher number of arterial segments than DSA (mean, 5.42 vs. mean 3.50, respectively), a difference which was statistically significant (p<0.000). The difference between each arterial segment was not statistically significant, except for the dorsalis pedis artery (t test, p<0.000). In that it provides additional information for

  10. Distribution coefficients for radionuclides in aquatic environments. Volume 2. Dialysis experiments in marine environments

    International Nuclear Information System (INIS)

    Sibley, T.H.; Nevissi, A.E.; Schell, W.R.

    1981-05-01

    The overall objective of this research program was to obtain new information that can be used to predict the fate of radionuclides that may enter the aquatic environment from nuclear power plants, waste storage facilities or fuel reprocessing plants. Important parameters for determining fate are the distribution of radionuclides between the soluble and particulate phases and the partitioning of radionuclides among various suspended particulates. This report presents the results of dialysis experiments that were used to study the distribution of radionuclides among suspended sediments, phytoplankton, organic detritus, and filtered sea water. Three experiments were conducted to investigate the adsorption kinetics and equilibrium distribution of (59)Fe, (60)Co, (65)Zn, (106)Ru, (137)Cs, (207)Bi, (238)Pu, and (241)Am in marine system. Diffusion across the dialysis membranes depends upon the physico-chemical form of the radionuclides, proceeding quite rapidly for ionic species of (137)Cs and (60)Co but much more slowly for radionuclides which occur primarily as colloids and solid precipitates such as (59)Fe, (207)Bi, and (241)Am. All the radionuclides adsorb to suspended particulates although the amount of adsorption depends upon the specific types and concentration of particulates in the system and the selected radionuclide. High affinity of some radionuclides - e.g., (106)Ru and (241)Am - for detritus and phytoplankton suggests that suspended organics may significantly affect the eventual fate of those radionuclides in marine ecosystems

  11. The effect of nitroglycerin on response to tracheal intubation. Assessment by radionuclide angiography

    International Nuclear Information System (INIS)

    Hart, A.P.; Camporesi, E.M.; Sell, T.L.; Croughwell, N.; Silva, R.; Jones, R.H.; McIntyre, R.W.; Stanley, T.E.; Reves, J.G.

    1989-01-01

    The effect of intravenous (IV) nitroglycerin (NTG) on perioperative myocardial ischemia as detected by single pass radionuclide angiocardiography was studied in 20 patients scheduled for elective coronary artery bypass grafting (CABG). Ten patients, selected at random, received IV NTG 1 microgram.kg-1.min-1 (NTG group) and 10 others, IV saline (control group). Anesthetic induction consisted of midazolam 0.2 mg.kg-1, vecuronium 0.1 mg.kg-1, and 50% N 2 O in O 2 . ECG leads I, II, and V5 were monitored for ST segment changes. Single pass radionuclide angiocardiography (RNA) was performed at 5 times: prior to induction, prior to tracheal intubation, and at 1, 3.5, and 6 min following intubation. The presence of new regional wall motion abnormalities (RWMA) was determined from each RNA study as compared with the preinduction measurement. Apart from one patient in the control group who developed a new ''v'' wave after intubation, there was no evidence of ischemia by pulmonary capillary wedge pressure. No ECG evidence of ischemia was detected in any patient. Despite this, new regional wall motion abnormalities were observed in 3 patients in the control group and 1 patient in the NTG group. Blood pressure and heart rate responses of patients with new RWMA were not significantly different from other patients. The low incidence of ischemia in this population precludes a definitive statement regarding the efficacy of IV NTG, but the lower incidence of RWMA in the NTG group suggests a protective effect

  12. Cardiac nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Gerson, M.C.

    1987-01-01

    The book begins with a review of the radionuclide methods available for evaluating cardiac perfusion and function. The authors discuss planar and tomographic thallium myocardial imaging, first-pass and equilibrium radionuclide angiography, and imaging with infarct-avid tracers. Several common but more specialized procedures are then reviewed: nonogemetric measurement of left ventricular volume, phase (Fourier) analysis, stroke volume ratio, right ventricular function, and diastolic function. A separate chapter is devoted to drug interventions and in particular the use of radionuclide ventriculography to monitor doxorubicin toxicity and therapy of congestive heart failure. The subsequent chapters provide a comprehensive guide to test selection, accuracy, and results in acute myocardial infarction, in postmyocardial infarction, in chronic coronary artery disease, before and after medical or surgical revascularization, in valvular heart disease, in cardiomyopathies, and in cardiac trauma.

  13. Cardiac nuclear medicine

    International Nuclear Information System (INIS)

    Gerson, M.C.

    1987-01-01

    The book begins with a review of the radionuclide methods available for evaluating cardiac perfusion and function. The authors discuss planar and tomographic thallium myocardial imaging, first-pass and equilibrium radionuclide angiography, and imaging with infarct-avid tracers. Several common but more specialized procedures are then reviewed: nonogemetric measurement of left ventricular volume, phase (Fourier) analysis, stroke volume ratio, right ventricular function, and diastolic function. A separate chapter is devoted to drug interventions and in particular the use of radionuclide ventriculography to monitor doxorubicin toxicity and therapy of congestive heart failure. The subsequent chapters provide a comprehensive guide to test selection, accuracy, and results in acute myocardial infarction, in postmyocardial infarction, in chronic coronary artery disease, before and after medical or surgical revascularization, in valvular heart disease, in cardiomyopathies, and in cardiac trauma

  14. Transport of radionuclides by concentrated brine in a porous medium with micropore-macropore structure

    International Nuclear Information System (INIS)

    Hassanizadeh, S.M.

    1987-01-01

    This work concerns itself with the study of effects of soil aggregation and high salt concentrations on the transport of radionuclides by concentrated brine flowing through an aggregated porous medium. The medium is considered to be composed of porous rock aggregates separated by macropores through which the brine flows and transport of salt and radionuclides takes place. The aggregates contain dead-end pores, cracks, and stationary pockets collectively called micropores. The micropore space does not contribute to the flow, but it serves as a storage for salt and radionuclides. Adsorption of radionuclides takes place at internal surfaces of aggregates where they assume that a linear equilibrium isotherm describes the process. A one-dimensional numerical model is developed which is based on two sets of equations: one set for the flow and transport of salt and another set for transport of radionuclides. Results of numerical experiments clearly indicate that the existence of high salt concentrations markedly reduces the peak of nuclides concentration and slows down their movement. Also, it is found that diffusive mass exchange between macropores and aggregates results in a pronounced lowering of the radionuclides concentration peaks. 9 references, 7 figures

  15. Segmental wall-motion analysis in the right anterior oblique projection: comparison of exercise equilibrium radionuclide ventriculography and exercise contrast ventriculography

    International Nuclear Information System (INIS)

    Brady, T.J.; Thrall, J.H.; Keyes, J.W. Jr.; Brymer, J.F.; Walton, J.A.; Pitt, B.

    1980-01-01

    Thirty-nine patients with known or suspected coronary artery disease were studied at rest and during supine bicycle exercise with radionuclide and contrast left ventriculography. Analysis of regional wall motion was made by visual evaluation of the five standard 30 0 right anterior oblique (RAO) wall segments in the contrast images and the corresponding 10 0 RAO radionuclide segments. The radionuclide studies were evaluated independently by three observers using a five-point grading system. The interobserver wall-motion grading agreed completely in more than 80% of segments at rest and exercise, and agreed within one wall-motion grade in more than 95% of segments. The comparison of wall-motion grades between radionuclide and contrast ventriculograms showed complete agreement in 86% of segments at rest and in 78% during exercise, and agreement within one wall-motion grade in 97% of rest and 96% of exercise segments. Visual evaluation of 10 0 RAO rest and exercise radionuclide ventriculograms compares favorably with rest and exercise 30 0 RAO contrast ventriculograms and demonstrates satisfactory interobserver agreement

  16. Radionuclide stroke count ratios for assessment of right and left ventricular volume overload in children

    International Nuclear Information System (INIS)

    Parrish, M.D.; Graham, T.P. Jr.; Born, M.L.; Jones, J.P.; Boucek, R.J. Jr.; Artman, M.; Partain, C.L.

    1983-01-01

    The ratio of left ventricular to right ventricular stroke counts measured by radionuclide angiography has been used in adults to estimate the severity of left-sided valvular regurgitation. The validation of this technique in children for assessment of right and left ventricular volume overload is reported herein. Radionuclide stroke count ratios in 60 children aged 0.5 to 19 years (mean 11) were determined. Based on their diagnoses, the patients were divided into 3 groups: (1) normal--40 patients with no shunts or valvular regurgitation, (2) left ventricular volume overload--13 patients with mitral or aortic regurgitation, or both, and (3) right ventricular volume overload--7 patients, 2 with severe tricuspid regurgitation, 3 with atrial septal defects, and 2 with total anomalous pulmonary venous drainage. The radionuclide stroke count ratio clearly differentiated these groups (p less than 0.05): normal patients had a stroke count ratio of 1.04 +/- 0.17 (mean +/- 1 standard deviation), the left ventricular volume overload group had a stroke count ratio of 2.43 +/- 0.86, and the right ventricular volume overload group had a stroke count ratio of 0.44 +/- 0.17. In 22 of our 60 patients, radionuclide stroke count ratios were compared with cineangiographic stroke volume ratios, resulting in a correlation coefficient of 0.88. It is concluded that radionuclide ventriculography is an excellent tool for qualitative and quantitative assessment of valvular regurgitation in children

  17. Kinetic aspects of the syntheses using short-lived radionuclides

    International Nuclear Information System (INIS)

    Laangstroem, B.; Obenius, U.; Sjoeberg, S.; Bergson, G.

    1981-01-01

    In syntheses using short-lived radionuclides, such as 11 C, the reaction conditions are usually such that the concentrations of the reactants, except for the labelled reactant, can be considered constant during the reaction. Two kinetic models have been investigated - irreversible and reversible bimolecular elementary reactions. The influence of the rate constants, of the equilibrium constants, and of the ratio between the starting reactants on the yield of the labelled product has been studied. The results show that, even in cases with unfavourable equilibrium constants, high yields of the labelled products can be obtained if the rate constant for the forward reaction is large. In addition, the specific activity of the labelled product as a function of time has been studied for the irreversible bimolecular case. (author)

  18. Use of {sup 123}I-MIBG scintigraphy to assess the impact of carvedilol on cardiac adrenergic neuronal function in childhood dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Maunoury, Christophe [Service de Medecine Nucleaire, Hopital Necker-Enfants Malades, 149 rue de Sevres, 75743, Paris Cedex 15 (France); Acar, Philippe; Sidi, Daniel [Service de Cardiologie Pediatrique, Hopital Necker-Enfants Malades, Paris (France)

    2003-12-01

    Iodine-123 metaiodobenzylguanidine (MIBG) cardiac scintigraphy is a useful tool for the assessment of cardiac adrenergic neuronal function, which is impaired in children with idiopathic dilated cardiomyopathy (DCM). In adults with DCM, long-term treatment with carvedilol improves both cardiac adrenergic neuronal function and left ventricular function. The aim of this prospective study was to evaluate the impact of carvedilol on cardiac adrenergic neuronal function using {sup 123}I-MIBG scintigraphy and on left ventricular function using equilibrium radionuclide angiography in children with DCM. Seventeen patients (11 female, six male; mean age 39{+-}57 months, range 1-168 months) with DCM and left ventricular dysfunction underwent {sup 123}I-MIBG cardiac scintigraphy and equilibrium radionuclide angiography before and after a 6-month period of carvedilol therapy. A static anterior view of the chest was acquired 4 h after intravenous injection of 20-75 MBq of {sup 123}I-MIBG. Cardiac neuronal uptake of {sup 123}I-MIBG was measured using the heart to mediastinum count ratio (HMR). Radionuclide left ventricular ejection fraction (LVEF) was assessed following a standard protocol. MIBG cardiac uptake and left ventricular function respectively increased by 38% and 65% after 6 months of treatment with carvedilol (HMR=223%{+-}49% vs 162%{+-}26%, P<0.0001, and LVEF=43%{+-}17% vs 26%{+-}11%, P<0.0001). Carvedilol can improve cardiac adrenergic neuronal and left ventricular function in children with dilated cardiomyopathy. Further studies are needed to assess the relationship between improvement in MIBG cardiac uptake and the beneficial effects of carvedilol on morbidity and mortality. (orig.)

  19. Use of 123I-MIBG scintigraphy to assess the impact of carvedilol on cardiac adrenergic neuronal function in childhood dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Maunoury, Christophe; Acar, Philippe; Sidi, Daniel

    2003-01-01

    Iodine-123 metaiodobenzylguanidine (MIBG) cardiac scintigraphy is a useful tool for the assessment of cardiac adrenergic neuronal function, which is impaired in children with idiopathic dilated cardiomyopathy (DCM). In adults with DCM, long-term treatment with carvedilol improves both cardiac adrenergic neuronal function and left ventricular function. The aim of this prospective study was to evaluate the impact of carvedilol on cardiac adrenergic neuronal function using 123 I-MIBG scintigraphy and on left ventricular function using equilibrium radionuclide angiography in children with DCM. Seventeen patients (11 female, six male; mean age 39±57 months, range 1-168 months) with DCM and left ventricular dysfunction underwent 123 I-MIBG cardiac scintigraphy and equilibrium radionuclide angiography before and after a 6-month period of carvedilol therapy. A static anterior view of the chest was acquired 4 h after intravenous injection of 20-75 MBq of 123 I-MIBG. Cardiac neuronal uptake of 123 I-MIBG was measured using the heart to mediastinum count ratio (HMR). Radionuclide left ventricular ejection fraction (LVEF) was assessed following a standard protocol. MIBG cardiac uptake and left ventricular function respectively increased by 38% and 65% after 6 months of treatment with carvedilol (HMR=223%±49% vs 162%±26%, P<0.0001, and LVEF=43%±17% vs 26%±11%, P<0.0001). Carvedilol can improve cardiac adrenergic neuronal and left ventricular function in children with dilated cardiomyopathy. Further studies are needed to assess the relationship between improvement in MIBG cardiac uptake and the beneficial effects of carvedilol on morbidity and mortality. (orig.)

  20. Radionuclide solubility control by solid solutions

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, F.; Klinkenberg, M.; Rozov, K.; Bosbach, D. [Forschungszentrum Juelich GmbH (Germany). Inst. of Energy and Climate Research - Nuclear Waste Management and Reactor Safety (IEK-6); Vinograd, V. [Frankfurt Univ. (Germany). Inst. of Geosciences

    2015-07-01

    The migration of radionuclides in the geosphere is to a large extend controlled by sorption processes onto minerals and colloids. On a molecular level, sorption phenomena involve surface complexation, ion exchange as well as solid solution formation. The formation of solid solutions leads to the structural incorporation of radionuclides in a host structure. Such solid solutions are ubiquitous in natural systems - most minerals in nature are atomistic mixtures of elements rather than pure compounds because their formation leads to a thermodynamically more stable situation compared to the formation of pure compounds. However, due to a lack of reliable data for the expected scenario at close-to equilibrium conditions, solid solution systems have so far not been considered in long-term safety assessments for nuclear waste repositories. In recent years, various solid-solution aqueous solution systems have been studied. Here we present state-of-the art results regarding the formation of (Ra,Ba)SO{sub 4} solid solutions. In some scenarios describing a waste repository system for spent nuclear fuel in crystalline rocks {sup 226}Ra dominates the radiological impact to the environment associated with the potential release of radionuclides from the repository in the future. The solubility of Ra in equilibrium with (Ra,Ba)SO{sub 4} is much lower than the one calculated with RaSO{sub 4} as solubility limiting phase. Especially, the available literature data for the interaction parameter W{sub BaRa}, which describes the non-ideality of the solid solution, vary by about one order of magnitude (Zhu, 2004; Curti et al., 2010). The final {sup 226}Ra concentration in this system is extremely sensitive to the amount of barite, the difference in the solubility products of the end-member phases, and the degree of non-ideality of the solid solution phase. Here, we have enhanced the fundamental understanding regarding (1) the thermodynamics of (Ra,Ba)SO{sub 4} solid solutions and (2) the

  1. MR angiography (MRA)

    Energy Technology Data Exchange (ETDEWEB)

    Hasuo, Kanehiro [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1995-12-01

    The primary goal of vascular imaging is the visualization of morphology and hemodynamics. Catheter angiography has been regarded as a gold standard for this purpose. However, MR angiography (MRA) is now increasingly being recognized as an important noninvasive technique for the depiction of vascular diseases and is partially superseding catheter angiography. The author evaluated the usefulness of MRA in the diagnosis of cerebral aneurysms and moyamoya disease. All aneurysms 5 mm or larger in diameter could be detected and most of those less than 5 mm in diameter were also detectable with using a combination of MIP images, target MIP images and source images. In moyamoya disease, the diagnosis could be made in all. For hemodynamic changes, flow directions in the circle of Willis could be visualized by phase-contrast MRA in a normal volunteer. In addition, MRA successfully showed the patency of surgical collaterals in cases of moyamoya disease. Despite some limitations compared with catheter angiography, MRA has a high sensitivity and specificity in the diagnosis of cerebrovascular abnormalities. Furthermore, screening of cerebral aneurysms or cerebrovascular occlusive diseases seems to be a new, and important indication for MRA. (author).

  2. Risk of renal allograft rejection following angiography

    International Nuclear Information System (INIS)

    Heideman, M.; Claes, G.; Nilson, A.E.

    1976-01-01

    In a retrospective study of 173 immediately functioning primary kidney transplants, correlation between angiography and renal allograft rejection was studied during the first 14 days. It was found that rejection was more frequent in kidneys undergoing angiography than in those not undergoing angiography. It was also found that in kidneys undergoing angiography an overwhelming number of the rejections started the day after angiography. These differences in rejection frequency could not be explained by differences in HLA matching or the origin of the kidneys. These findings suggest a possible connection indicating that the angiography might elicit an acute rejection episode. A possible mechanism for starting this reaction might be activation of the complement system which was found in 50 percent of the patients undergoing angiography in peripheral blood and in 100 percent when studied in vitro

  3. Digital subtraction angiography in ischemic cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P. (Hopital Purpan, 31 - Toulouse (France))

    1983-12-29

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery.

  4. Digital subtraction angiography in ischemic cerebrovascular accidents

    International Nuclear Information System (INIS)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P.

    1983-01-01

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery [fr

  5. Vasovist-enhanced MR angiography

    International Nuclear Information System (INIS)

    Goyen, M.; Shamsi, K.; Schoenberg, S.O.

    2006-01-01

    Vasovist (MS-325) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. Vasovist reversibly binds to albumin, providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive testing to evaluate the safety and efficacy of the drug; the clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (AIOD, renal, pedal), examination of potential drug interaction with warfarin and comparison with XRA. The clinical trials show that Vasovist-enhanced MR angiography is safe and well-tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. (orig.)

  6. Vasovist-enhanced MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Goyen, M. [Univ. Medical Center, Hamburg-Eppendorf, Hamburg (Germany); Shamsi, K. [Berlex Lab., Inc., Montville, NJ (United States); Schoenberg, S.O. [Dept. of Clinical Radiology, Univ. Hospitals Grosshadern, Munich (Germany)

    2006-02-15

    Vasovist (MS-325) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. Vasovist reversibly binds to albumin, providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive testing to evaluate the safety and efficacy of the drug; the clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (AIOD, renal, pedal), examination of potential drug interaction with warfarin and comparison with XRA. The clinical trials show that Vasovist-enhanced MR angiography is safe and well-tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. (orig.)

  7. Is fasting necessary for elective cerebral angiography?

    Science.gov (United States)

    Kwon, O-K; Oh, C W; Park, H; Bang, J S; Bae, H-J; Han, M K; Park, S-H; Han, M H; Kang, H-S; Park, S-K; Whang, G; Kim, B-C; Jin, S-C

    2011-05-01

    In order to prevent unexpected events such as aspiration pneumonia, cerebral angiography has been performed under fasting in most cases. We investigated prospectively the necessity of fasting before elective cerebral angiography. The study is an open-labeled clinical trial without random allocation. In total, 2554 patients who underwent elective cerebral angiography were evaluated on development of nausea, vomiting, and pulmonary aspiration during and after angiography. Potential risks and benefits associated with fasting were provided in written documents and through personal counseling to patients before the procedure. The patients chose their fasting or nonfasting option. No restriction in diet was given after angiography. The patients were observed for 24 hours. Nausea and vomiting during and within 1 hour after angiography was considered as a positive event associated with cerebral angiography. The overall incidence of nausea and vomiting during and within 1 hour after angiography was 1.05% (27/2554 patients). There was no patient with pulmonary aspiration. No statistical difference in nausea and vomiting development between the fasting and the diet groups was found. The incidence of nausea and vomiting associated with cerebral angiography is low and not affected by diet or fasting. Pulmonary aspiration had no difference between the diet and the fasting group. Our study suggests that fasting may not be necessary for patients who undergo elective cerebral angiography.

  8. Biological transfer of radionuclides in marine environments - Identifying and filling knowledge gaps for environmental impact assessments

    International Nuclear Information System (INIS)

    Brown, J.E.; Borretzen, P.; Hosseini, A.; Iosjpe, M.

    2004-01-01

    A review on concentration factors (CF) for the marine environment was conducted in order to consider the relevance of existing data from the perspective of environmental protection and to identify areas of data paucity. Data have been organised in a format compatible with a reference organism approach, for selected radionuclides, and efforts have been taken to identify the factors that may be of importance in the context of dosimetric and dose-effects analyses. These reference organism categories had been previously selected by identifying organism groups that were likely to experience the highest levels of radiation exposure, owing to high uptake levels or residence in a particular habitat, for defined scenarios. Significant data gaps in the CF database have been identified, notably for marine mammals and birds. Most empirical information pertains to a limit suite of radionuclides, particularly 137 Cs, 210 Po and 99 Tc. A methodology has been developed to help bridge this information deficit. This has been based on simple dynamic, biokinetic models that mainly use parameters derived from laboratory-based study and field observation. In some cases, allometric relationships have been employed to allow further model parameterization. Initial testing of the model by comparing model output with empirical data sets suggest that the models provide sensible equilibrium CFs. Furthermore, analyses of modelling results suggest that for some radionuclides, in particularly those with long effective half-lives, the time to equilibrium can be far greater than the life-time of an organism. This clearly emphasises the limitations of applying a universal equilibrium approach. The methodology, therefore, has an added advantage that non-equilibrium scenarios can be considered in a more rigorous manner. Further refinements to the modelling approach might be attained by exploring the importance of various model parameters, through sensitivity analyses, and by identifying those

  9. Indications for coronary angiography

    International Nuclear Information System (INIS)

    Kaltenbach, M.; Vallbracht, C.

    1985-01-01

    Today selective coronary angiography, introduced by Sones in 1957, is used as clinical routine for diagnosing morphological changes in the coronary arteries. Hitherto, more recent techniques such as digital subtraction angiography cannot provide comparable information. Strict criteria for its indication depending on possible therapeutic consequences, have to be applied, although the risk is low with a letality of 0.01 to 0.05 percent. Radionuclear investigations can be used as additional tool in selected cases. The careful indication for coronary angiography usually implies the possible need for coronary bypass graft surgery of balloon angioplasty. (orig./MG) [de

  10. Gadolinium-enhanced MR angiography of arterial occlusive disease in lower extremity : comparison with conventional digital subtraction angiography

    International Nuclear Information System (INIS)

    Shin, Sang June; Koh, Young Hwan; Cha, Joo Hee; Kim, Hyu Beom; Chung, Jin Wook; Park, Jae Hyung

    2000-01-01

    To compare the diagnostic value of gadolinium-enhanced MR angiography with that of conventional digital subtraction angiography for the evaluation of lower extremity arterial occlusive diseases. In 26 patients with symptomatic lower extremity arterial occlusive disease, both conventional digital subtraction angiography (DSA) and gadolinium-enhanced MR angiography (CE-MRA) were performed during the same week. MR angiography was performed using three-dimensional gradient-echo acquisition before, and two sequential acquisitions after, the administration of gadolinium (0.2 mmol/kg). In 23 patients, two separate, contiguous areas were scanned using additional doses. In three patients, only one field with a suspicious lesion was scanned. Three radiologists independently analyzed the CE-MRA and DSA findings of each vascular segment (20 segments per arterial tree) for the presence of obstructive lesions; the grade assigned was either mild or none (less than 50%), stenotic (50%-99%), or occlusion (100%). From among a total of 462 segments, DSA detected 99 which were significantly narrowed (stenosis, 33; occlusion, 66). Using MR angiography, 102 segments (stenosis 39; occlusion, 63) were identified, and 94 lesions (stenosis, 32; occlusion, 62) were graded correctly. Seven lesions were overestimated and four were underestimated. For the detection of hemodynamically significant stenosis or occlusions using MR angiography, sensitivity, specificity, and diagnostic accuracy were 95%, 98%, and 98% (G=3D0.995, P less than 0.001), respectively. To prove the absence of lesions, we repeated DSA in two patients with arterial spasm due to puncture. Three occluded segments seen on DSA, which revealed intact segments on MR angiography, suggested slow distal flow after reconstitution. For the evaluation of lower extremity arterial occlusive disease, the diagnostic value of gadolinium-enhanced MR angiography is comparable with that of digital subtraction angiography. The advantages of the

  11. MR angiography in pediatric neurological disorders

    International Nuclear Information System (INIS)

    Lee, B.C.P.; Park, T.S.; Kaufman, B.A.

    1995-01-01

    MR angiography using 3D and 2D time-of-flight techniques were used to evaluate pediatric neurological disorders. MRA (arteriography) and MRV (venography) were abnormal in 63 and 45 cases, respectively. Conventional cerebral angiography was performed in 30 cases. These techniques were compared with MRI and conventional angiography. In addition, the value of MR angiography for surgical planning was subjectively evaluated. Our results showed that intracranial vessels were invariably better shown on MR angiography than on MRI. MRA and MRV were most useful in evaluating vascular distortions related to congenital brain malformations and intracranial tumors. MRA was valuable in detecting arterial narrowing but overestimated the degree of stenosis compared with conventional angiography. MRV was the technique of choice for evaluation of dural sinus and cerebral venous thrombosis and compression. MRA played little to no role in preoperative planning of vascular malformations and aneurysms. It did not appear to be accurate in assessing tumor vascularity or lesions in small arteries and arteritis. (orig.)

  12. Radionuclide angiographic evaluation of left ventricular performance at rest and during exercise in patients with aortic regurgitation

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Heo, J.

    1986-01-01

    Radionuclide angiographic evaluation of LV performance at rest and during exercise in patients with AR have shown that an abnormal EF response to exercise may be observed in asymptomatic patients with normal resting LV function. The EF response to exercise has been correlated with a number of clinical and exercise measurements; important among these are the slope of the systolic pressure-to-end-systolic volume, end-systolic volume, cardiac index, pulmonary capillary wedge pressure, and wall stress. The changes in the regurgitant fraction, EF, and LV volume have shown considerable individual variability; they have also allowed a better understanding of the circulatory responses during exercise. Radionuclide angiography provides a reliable and reproducible method of measuring the rest LVEF that is important in the timing and the outcome of valve replacement. The value of the EF response to exercise in patient management is not yet clear; it is possible that other radionuclide-derived measurements at rest or during exercise, such as the systolic pressure-to-end-systolic volume relationship, and the end-systolic volume may provide complementary information to that provided by the EF

  13. Multi-section CT angiography compared with digital subtraction angiography in diagnosing major arterial hemorrhage in inflammatory pancreatic disease

    International Nuclear Information System (INIS)

    Hyare, Harpreet; Desigan, Sharmini; Nicholl, Helen; Guiney, Michael J.; Brookes, Jocelyn A.; Lees, William R.

    2006-01-01

    Purpose: Major arterial hemorrhage is an uncommon but serious complication of pancreatitis with high morbidity and mortality. Digital subtraction angiography (DSA) has long been the gold standard for the detection of a visceral artery pseudoaneurysm or for the site of active bleeding in patients with pancreatitis. Multi-section CT angiography is a minimally invasive technique which can provide high-resolution and high-contrast images of the arterial lumen and wall, with a much lower risk of complication and morbidity compared to DSA. The aim of this study was to determine the accuracy of multi-section CT angiography for the diagnosis of arterial complications of inflammatory pancreatitic disease. Materials and methods: A retrospective analysis of all patients undergoing visceral angiography for major bleeding as a complication of pancreatitis between 1998 and 2004 was performed. Twenty-nine studies in 25 patients (20 males, 5 females) with a mean age of 50.9 years (range 11-67 years) were identified where multi-section CT angiography was performed in the 24 h preceding the digital subtraction angiogram. Results: Digital subtraction angiography detected a pseudoaneurysm or contrast extravasation in 19 studies and no bleeding was demonstrated in 9 studies. CT angiography correctly identified the site and type of bleeding in 18 of the 19 positive studies. CT angiography detected extravasation of contrast in one study that was not demonstrated on digital subtraction angiography. The sensitivity and specificity for multi-section CT angiography for the detection of major arterial bleeding on a background of pancreatitis were 0.947 and 0.900, respectively. Conclusion: Multi-section CT angiography is a sensitive and accurate technique for the detection of major arterial hemorrhage in inflammatory pancreatic disease and should be considered as the first investigation in the management of these patients

  14. Digital angiography in pulmonary embolism

    International Nuclear Information System (INIS)

    Bjoerk, L.

    1986-01-01

    Pulmonary digital subtraction angiography was diagnostic in 98.3% of patients with possible acute pulmonary embolism. The procedure was well tolerated even in severely ill patients. A large image intensifier made simultaneous imaging of both lungs possible reducing the number of contrast injections necessary. Small volumes of low iso-osmolar concentration of modern contrast media were used. There was no need for catherization of the pulmonary artery. Theoretical considerations and our limited experience indicate that this will reduce the number of complications compared with conventional pulmonary angiography. The procedure is rapidly performed and the diagnostic accuracy high. This makes digital subtraction angiography cost effective. Digital pulmonary angiography can be recommended as the primary diagnostic method in most patients with possible pulmonary embolism. (orig.)

  15. Infrared-laser-based fundus angiography

    Science.gov (United States)

    Klingbeil, Ulrich; Canter, Joseph M.; Lesiecki, Michael L.; Reichel, Elias

    1994-06-01

    Infrared fundus angiography, using the fluorescent dye indocyanine green (ICG), has shown great potential in delineating choroidal neovascularization (CNV) otherwise not detectable. A digital retinal imaging system containing a diode laser for illumination has been developed and optimized to perform high sensitivity ICG angiography. The system requires less power and generates less pseudo-fluorescence background than nonlaser devices. During clinical evaluation at three retinal centers more than 200 patients, the majority of which had age-related macular degeneration, were analyzed. Laser based ICG angiography was successful in outlining many of the ill-defined or obscure CNV as defined by fluorescein angiography. The procedure was not as successful with classic CNV. ICG angiograms were used to prepare and guide laser treatment.

  16. Direct and precise determination of environmental radionuclides in solid materials using a modified Marinelli beaker and a HPGe detector

    International Nuclear Information System (INIS)

    Seo, B.K.; Lee, D.W.; Lee, K.Y.; Yoon, Y.Y.

    2001-01-01

    A simple but precise detection method was studied for the determination of natural radionuclides using a conventional HPGe detector. A new aluminium beaker instead of a plastic Marinelli beaker was constructed and examined to reach radioactive equilibrium conditions between radon and its daughter elements without the escape of gaseous radon. Using this beaker fifteen natural radionuclides from three natural decay series could be determined by direct γ-ray measurement and sixteen radionuclides could be determined indirectly after radioactive equilibrium had been reached. Analytical results from ground water were compared with those from conventional α spectroscopy and the results agreed well within 12% difference. Nitrogen gas purge was used to replace the surrounding air of the detector to obtain a stable background and reducing the interference of radon daughter nuclides in the atmosphere. The use of nitrogen purging and the aluminium Marinelli beaker results in an approximately tenfold increase of sensitivity and a decrease of the detection limit of 226 Ra to about 0.74 Bq kg -1 in soil samples. (orig.)

  17. Direct and precise determination of environmental radionuclides in solid materials using a modified Marinelli beaker and a HPGe detector.

    Science.gov (United States)

    Seo, B K; Lee, K Y; Yoon, Y Y; Lee, D W

    2001-06-01

    A simple but precise detection method was studied for the determination of natural radionuclides using a conventional HPGe detector. A new aluminium beaker instead of a plastic Marinelli beaker was constructed and examined to reach radioactive equilibrium conditions between radon and its daughter elements without the escape of gaseous radon. Using this beaker fifteen natural radionuclides from three natural decay series could be determined by direct gamma-ray measurement and sixteen radionuclides could be determined indirectly after radioactive equilibrium had been reached. Analytical results from ground water were compared with those from conventional alpha spectroscopy and the results agreed well within 12% difference. Nitrogen gas purge was used to replace the surrounding air of the detector to obtain a stable background and reducing the interference of radon daughter nuclides in the atmosphere. The use of nitrogen purging and the aluminium Marinelli beaker results in an approximately tenfold increase of sensitivity and a decrease of the detection limit of 226Ra to about 0.74 Bq kg(-1) in soil samples.

  18. Soil-to-plant transfer factors of stable elements and naturally occurring radionuclides. (2) Rice collected in Japan

    International Nuclear Information System (INIS)

    Uchida, Shigeo; Tagami, Keiko; Hirai, Ikuko

    2007-01-01

    The critical paths of radionuclides and the critical foods in Japan are different from those in European and North American countries because agricultural products and food customs are different. Consequently, safety assessment in Japan is required to consider rice and vegetables as the critical foods. In this study, we measured soil-to-plant transfer factors (TFs) for rice using naturally existing elements as analogues of radionuclides under equilibrium conditions. Rice and associated soil samples were collected from 50 sampling sites throughout Japan and TFs of 36 and 34 elements for brown rice and white rice, respectively, were calculated on dry weight basis. Probability distributions of TFs of elements for brown rice and white rice were a log normal type. Except for As and Mo, the TFs for brown rice were usually lower than those for wheat and barley especially for K, Fe, Sr (t-test: p 90 Sr and 137 Cs observed in field experiments. Thus, the TFs of naturally existing elements can be used as TFs of those radionuclides which have been in contact with the environment for a long time and have reached equilibrium conditions. (author)

  19. Colloid-facilitated radionuclide transport: a regulatory perspective

    Science.gov (United States)

    Dam, W. L.; Pickett, D. A.; Codell, R. B.; Nicholson, T. J.

    2001-12-01

    investigating approaches to colloid modeling in order to help evaluate DOE's approach. One alternative approach uses DOE laboratory data to invoke kinetic controls on reversible radionuclide attachment to colloids. A kinetic approach in which desorption from colloids is slow may help assess whether DOE's instantaneous equilibrium approach for reversible attachment, as well as their application of irreversible attachment to only a small portion of the radionuclide inventory, are reasonable and conservative. An approach to examine microbial processes would also contribute to considerations of leaching of radionuclides and colloid formation. Reducing uncertainties in colloid transport processes should help in better understanding their importance to repository performance. This work is an independent product and does not necessarily reflect the views or regulatory position of the NRC. CNWRA participation was funded under contract No. NRC-02-97-009.

  20. Natural radionuclides in soils from Sao Paulo State cerrado forest

    International Nuclear Information System (INIS)

    Miranda, Marcia V.F.E.S.; Farias, Emerson E.G. de; Cantinha, Rebeca S.; Franca, Elvis J. de

    2015-01-01

    Considering the long life history, forests should be preferentially evaluated for the monitoring of radionuclides, mainly artificial radioisotopes. However, little is known about nuclides from Uranium and Thorium series, as well as, K-40, in soils from the Sao Paulo State forests. Soils are the main reservoir of natural radionuclides for vegetation, thereby deserving attention. Taking into account the advantages of High-Resolution Gamma-ray Spectrometry (HRGS), diverse radionuclides can be quantified simultaneously. In this work natural radionuclides in soils from the Estacao Ecologica de Assis were evaluated by HRGS. Samples of 0-10 cm depth were collected under crown projection of most abundant tree species of long-term plots installed within the Estacao Ecologica de Assis, Sao Paulo State, Brazil. After drying and milling until 0.5 mm particle size, test portions of 30 g were transferred to polypropylene vials, sealed with silicone and kept under controlled conditions until 30 days to achieve secular equilibrium. A group of gamma-ray spectrometers was used to analyze about 27 samples by 80,000 seconds. Activity concentrations of Pb-214, Ac-228 and K-40 and their respective expanded analytical uncertainties at the 95% confidence level were calculated by Genie software from Canberra. Abnormal values were not detected for radionuclides in soils samples, however K-40 activity concentrations changed considerably due to the mineral cycling, in which K and, consequently K-40, is mainly stocked in vegetation in spite of soils. (author)

  1. Natural radionuclides in soils from Sao Paulo State cerrado forest

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Marcia V.F.E.S.; Farias, Emerson E.G. de; Cantinha, Rebeca S.; Franca, Elvis J. de, E-mail: mvaleria@cnen.gov.br, E-mail: emersonemiliano@yahoo.com.br, E-mail: rebecanuclear@gmail.com, E-mail: ejfranca@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2015-07-01

    Considering the long life history, forests should be preferentially evaluated for the monitoring of radionuclides, mainly artificial radioisotopes. However, little is known about nuclides from Uranium and Thorium series, as well as, K-40, in soils from the Sao Paulo State forests. Soils are the main reservoir of natural radionuclides for vegetation, thereby deserving attention. Taking into account the advantages of High-Resolution Gamma-ray Spectrometry (HRGS), diverse radionuclides can be quantified simultaneously. In this work natural radionuclides in soils from the Estacao Ecologica de Assis were evaluated by HRGS. Samples of 0-10 cm depth were collected under crown projection of most abundant tree species of long-term plots installed within the Estacao Ecologica de Assis, Sao Paulo State, Brazil. After drying and milling until 0.5 mm particle size, test portions of 30 g were transferred to polypropylene vials, sealed with silicone and kept under controlled conditions until 30 days to achieve secular equilibrium. A group of gamma-ray spectrometers was used to analyze about 27 samples by 80,000 seconds. Activity concentrations of Pb-214, Ac-228 and K-40 and their respective expanded analytical uncertainties at the 95% confidence level were calculated by Genie software from Canberra. Abnormal values were not detected for radionuclides in soils samples, however K-40 activity concentrations changed considerably due to the mineral cycling, in which K and, consequently K-40, is mainly stocked in vegetation in spite of soils. (author)

  2. Study on experimental models to analyze radionuclide migration behaviors through porous geologic media

    International Nuclear Information System (INIS)

    Tanaka, Tadao; Mukai, Masayuki

    2012-08-01

    The migration phenomenon of radionuclide through geological media such as soils and porous rocks, which is important in underground disposal of radioactive wastes, can be described by the advection-dispersion of groundwater and the interactions of radionuclide with geological media. On the other hand, to understand the migration phenomenon, actual migration data are experimentally acquired by a batch test, a column test and field trial. In the present study, experimental models about the interactions of radionuclide between the solid phase and the liquid phase were discussed systematically to interpret the migration data acquired by the various techniques and conditions. Equilibrium, reversibility, linearity, mechanism and chemistry in the interactions were considered in discussion of the experimental models. A calculation program, which can analyze migration data obtained under various conditions by applying the selected 9 types of experimental models, was maintained. The calculation program makes it be able to predict the migration behavior of radionuclide under various conditions and to decide the important parameter by a fitting analysis of the migration data. (author)

  3. Radionuclide salivary gland imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mishkin, F.S.

    1981-10-01

    Salivary gland imaging with 99mTc as pertechnetate provides functional information concerning trapping and excretion of the parotid and submandibular glands. Anatomic information gained often adds little to clinical evaluation. On the other hand, functional information may detect subclinical involvement, which correlates well with biopsy of the minor labial salivary glands. Salivary gland abnormalities in systemic disease such as sarcoidosis, rheumatoid arthritis, lupus erythematosus, and other collagenvascular disorders may be detected before they result in the clinical manifestaions of Sjoegren's syndrome. Such glands, after initially demonstrating increased trapping in the acute phase, tend to have decreased trapping and failure to discharge pertechnetate in response to an appropriate physiologic stimulus. Increased uptake of gallium-67 citrate often accompanies these findings. Inflammatory parotitis can be suspected when increased perfusion is evident on radionuclide angiography with any agent. The ability of the salivary gland image to detect and categorize mass lesions, which result in focal areas of diminished activity such as tumors, cysts, and most other masses, is disappointing, while its ability to detect and categorize Warthin's tumor, which concentrates pertechnetate, is much more valuable, although not specific.

  4. Radionuclide salivary gland imaging

    International Nuclear Information System (INIS)

    Mishkin, F.S.

    1981-01-01

    Salivary gland imaging with 99mTc as pertechnetate provides functional information concerning trapping and excretion of the parotid and submandibular glands. Anatomic information gained often adds little to clinical evaluation. On the other hand, functional information may detect subclinical involvement, which correlates well with biopsy of the minor labial salivary glands. Salivary gland abnormalities in systemic disease such as sarcoidosis, rheumatoid arthritis, lupus erythematosus, and other collagenvascular disorders may be detected before they result in the clinical manifestaions of Sjoegren's syndrome. Such glands, after initially demonstrating increased trapping in the acute phase, tend to have decreased trapping and failure to discharge pertechnetate in response to an appropriate physiologic stimulus. Increased uptake of gallium-67 citrate often accompanies these findings. Inflammatory parotitis can be suspected when increased perfusion is evident on radionuclide angiography with any agent. The ability of the salivary gland image to detect and categorize mass lesions, which result in focal areas of diminished activity such as tumors, cysts, and most other masses, is disappointing, while its ability to detect and categorize Warthin's tumor, which concentrates pertechnetate, is much more valuable, although not specific

  5. Comparative analysis of radionuclide inhalation and perfusion lung imaging with X ray pulmonary angiography for the diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Zhang Yanyan; Chen Man; Shao Maogang; Zhang Songlin; Mao Jieming; Guo Jingxuan

    1993-01-01

    The result of radionuclide lung imaging was compared in 18 patients of pulmonary embolism (PE) and 2 normal persons. The discovered perfusion defects correlated well with the location of angiographic obstruction. The positive angiographic and radionuclide finding was in 141 and 104 emboli arteries respectively. The sensitivity of total emboli pulmonary segments of lung imaging was 73.8%, the specificity was 82.7 and the accuracy was 79%. The techniques correlated quite well (r = 0.83, P<0.001)

  6. Determination of γ-rays emitting radionuclides in surface water: application of a quantitative biosensing method

    International Nuclear Information System (INIS)

    Wolterbeek, H. Th.; Van der Meer, A. J. G. M.

    1995-01-01

    A quantitative biosensing method has been developed for the determination of γ-rays emitting radionuclides in surface water. The method is based on the concept that at equilibrium the specific radioactivity in the biosensor is equal to the specific radioactivity in water. The method consists of the measurement of both the radionuclide and the related stable isotope (element) in the biosensor and the determination of the element in water. This three-way analysis eliminates problems such as unpredictable biosensor behaviour, effects of water elemental composition or further abiotic parameters on accumulation levels: what remains is the generally high enrichment (bioaccumulation factor BCF) of elements and radionuclides in the biosensor material. Using water plants, the method is shown to be three to five orders of magnitude more sensitive than the direct analysis of water. (author)

  7. Determination of {gamma}-rays emitting radionuclides in surface water: application of a quantitative biosensing method

    Energy Technology Data Exchange (ETDEWEB)

    Wolterbeek, H Th; Van der Meer, A. J. G. M. [Delft University of Technology, Interfaculty Reactor Institute, Mekelweg 15, 2629 JB Delft (Netherlands)

    1995-12-01

    A quantitative biosensing method has been developed for the determination of {gamma}-rays emitting radionuclides in surface water. The method is based on the concept that at equilibrium the specific radioactivity in the biosensor is equal to the specific radioactivity in water. The method consists of the measurement of both the radionuclide and the related stable isotope (element) in the biosensor and the determination of the element in water. This three-way analysis eliminates problems such as unpredictable biosensor behaviour, effects of water elemental composition or further abiotic parameters on accumulation levels: what remains is the generally high enrichment (bioaccumulation factor BCF) of elements and radionuclides in the biosensor material. Using water plants, the method is shown to be three to five orders of magnitude more sensitive than the direct analysis of water. (author)

  8. Dependence of alpha radionuclide diffusion and deposition on relative air humidity

    International Nuclear Information System (INIS)

    Danis, A.; Ciubotariu, M.; Oncescu, M.; Mocsy, I.; Tomulescu, V.

    2000-01-01

    The diffusion and deposition of the gaseous and solid alpha radionuclides/aerosols depend strongly on the relative air humidity. This dependence gets a great significance in the case of radon and their genetically related alpha radionuclides monitoring in the dwelling and working places for radioprotection purposes, particularly in establishing the equilibrium factor. For the gaseous and solid alpha radionuclides genetically related, Rn-222 and its solid alpha descendants including their aerosols obtained by radionuclide attachments to different particles present in air, the vertical gradient of volume concentrations was experimentally determined. The experiments were performed in: an airtight tubular laboratory chamber, a house cellar (Cluj-Napoca) and the entrance gallery of an abandoned mine (Avram Iancu, Bihor), in which the relative humidity was ranging from 65% up to 96%. For the laboratory chamber, these radionuclides were generated by a calibrated Ra-226 source, prepared at the Radionuclide Production Centre, IPNE-HH, Bucharest. The source was included into an air tight device with a well known volume and it was used only after 40 days, when the Ra-226 and its alpha descendants were under radioactive equilibrium. For the diffusion/deposition studies, this source was coupled with the airtight laboratory chamber. In the mine gallery and house cellar, the radon and its descendants were naturally and continuously generated by radium sources in soil and building materials. The alpha volume concentration determinations required the use of a very accurate and sensitive alpha measurement method. These requirements were met by the alpha track method. This method was used by us in the following conditions: the CR-39 plastic track detector (Page, England) for the detection of the alpha particles and the optical microscopy for the study of alpha tracks (Wild stereomicroscope M7S and a Karl Zeiss Jena binocular microscope). The volume concentrations of radon and the

  9. Radionuclides in peat bogs and energy peat

    International Nuclear Information System (INIS)

    Helariutta, K.; Rantavaara, A.; Lehtovaara, J.

    2000-06-01

    The study was aimed at improving the general view on radionuclides contents in energy peat produced in Finland. The annual harvest of fuel peat in 1994 was studied extensively. Also thirteen peat bogs used for peat production and one bog in natural condition were analysed for vertical distributions of several radionuclides. These distributions demonstrate the future change in radioactivity of energy peat. Both natural nuclides emitting gamma radiation ( 238 U, 235 U, 232 Th, 226 Ra, 40 K) and radiocaesium ( 137 Cs, 134 Cs) origin in fallout from a nuclear power plant accident (1986) and in atmospheric nuclear weapon tests were analysed. The beta and alpha active natural nuclides of lead and polonium ( 210 Pb, 210 Po) were determined on a set of peat samples. These nuclides potentially contribute to radiation exposure through inhalation when partially released to atmosphere during combustion of peat. The activity concentrations of natural radionuclides often increased towards the deepest peat bog layers whereas the radioactive caesium deposited from atmosphere was missing in the deep layers. In undisturbed surface layers of a natural bog and peat production bogs the contents of 210 Pb and 210 Po exceeded those of the deeper peat layers. The nuclides of the uranium series in the samples were generally not in radioactive equilibrium, as different environmental processes change their activity ratios in peat. Radiation exposure from handling and utilisation of peat ash was estimated with activity indices derived from the data for energy peat harvested in 1994. Intervention doses were exceeded in a minor selection of samples due to 137 Cs, whereas natural radionuclides contributed very little to the doses. (orig.)

  10. Radionuclide fluxes at a plant manufacturing dicalcium phosphate for domestic animals

    International Nuclear Information System (INIS)

    Gaefvert, T.; Holm, E.

    2002-01-01

    The objectives of this study is to map out the fluxes of radionuclides from the 238 U decay series as well as estimate doses to workers at a dicalcium phosphate plant. At the studied plant phosphate rock is used for the production of dicalcium phosphate, which is a source of calcium and phosphorous for domestic animals. A by-product in the manufacturing process is calcium chloride which is used in the oil industry, food industry and as road salt. In the phosphate rock, the radionuclides were found in secular radioactive equilibrium with an average activity concentration of 830 Bq·kg -1 . Separation and concentration processes was observed. Most of the 226 Ra was found in the calcium chloride while the major part of 238 U was found in the dicalcium phosphate, about 950 Bq·kg -1 . The annual occupational effective dose to workers was found to be below the 1 mSv limit. The study shows a good example of an important non-nuclear industry with a high input of natural radionuclides and several conceivable pathways to man. (author)

  11. Comparison of gadofosveset-enhanced three-dimensional magnetic resonance angiography with digital subtraction angiography for lower-extremity peripheral arterial occlusive disease

    International Nuclear Information System (INIS)

    Grijalba, Fermin Urtasun; Esandi, Mercedes Ciriza

    2010-01-01

    Background: Minimally invasive imaging techniques are increasingly used for clinical decision making in patients with peripheral arterial occlusive disease (PAOD). Purpose: To assess whether gadofosveset-enhanced three-dimensional (3D) magnetic resonance (MR) angiography could replace digital subtraction angiography (DSA) for the evaluation of lower-extremity PAOD. Material and Methods: Thirty patients with symptomatic PAOD underwent prospectively both MR angiography and DSA. Gadofosveset-enhanced 3D MR angiography was performed on a 1.5T system equipped with a peripheral angio matrix coil. Four blinded observers independently analyzed MR angiograms and DSA images. The lower arterial vascular system was divided into three anatomic segments (aortoiliac, femoropopliteal, infrapopliteal) for review. The status of each segment was graded as normal, stenosis less than 50%, stenosis greater than 50%, or occluded and/or aneurismatic. Principal and secondary lesions were reported. Results: Although interobserver agreement for both was excellent, it was higher for DSA (?=0.92) than for MR angiography (?=0.86) for reporting the principal and secondary lesions in all segments. For different anatomic locations, the interobserver agreement of MR angiography and DSA was as follows: aortoiliac (?=0.93, k=0.95), femoropopliteal (?=0.86, k=0.90), and infrapopliteal (?=0.78, k=0.85). The lowest agreement was found for MR angiography on infrapopliteal segments (?=0.78). In four (13.3%) cases, MR angiography showed lesions that were not found by DSA. Five (16.6%) aneurysm cases, not observed by DSA, were shown by MR angiography. Conclusion: Gadofosveset-enhanced 3D MR angiography can be proposed for first-line imaging in the management of lower-limb PAOD patients and permits the selective use of DSA as a second-line examination when MR angiography fails or in an endovascular approach

  12. MDCT angiography and transcatheter embolization in management ...

    African Journals Online (AJOL)

    Hassan Abdelsalam

    2015-12-18

    Dec 18, 2015 ... 14 patients did not have a MDCT and proceeded straight to angiography;. 6 of them showed active bleeding on angiography. Conclusion: MDCT is an excellent technique before angiography and embolization in cases with acute gastrointestinal bleeding. Transcatheter embolization is an effective tool for ...

  13. Digital subtraction angiography of the heart and lungs

    International Nuclear Information System (INIS)

    Moodie, D.S.; Yiannikas, J.

    1986-01-01

    This book contains 12 chapters. Some of the chapter titles are: Physical Principles of Cardiac Digital Subtraction Angiography, The Use of Intravenous Digital Subtraction Angiography in Evaluating Patients with Complex Congenital Heart Disease, Exercise Intravenous Digital Subtraction Angiograpny, Cardiomyopathic and Cardiac Neoplastic Disease, Digital Subtraction Angiography in the Catheterization Laboratory, and Cardiac Digital Subtraction Angiography - Future Directions

  14. Application of OCT angiography in ophthalmology

    Directory of Open Access Journals (Sweden)

    Ai-Ping Yang

    2017-11-01

    Full Text Available Optical coherence tomography angiography(OCTAis a new technology of angiography in recent years. In addition to the advantages of traditional OCT, it can observe blood flow in different retinal and choroidal segmentation slab. By using the pseudo-color, abnormal vascular structure can be distinguished from normal vascular structure of the retina. Dye injection is not needed with OCTA, which is different from fundus fluorescein angiography(FFAand indocyanine green angiography(ICGA. OCTA provides more and more accurate blood flow information. However, like other biometric technology, OCTA has its limitations and shortcomings. This review will analyze and summarize the operating principle of OCTA, its application in ophthalmology, as well as its advantages and limitations.

  15. Mathematical modelling of radionuclide transport through fractured rock using numerical inversion of Laplace transforms: applications to INTRACOIN Level 3

    International Nuclear Information System (INIS)

    Hodgkinson, D.P.; Lever, D.A.; England, T.H.

    1984-01-01

    A model for the transport of radionuclides through fractured rock has been developed and used to study a problem which forms part of Level 3 of the INTRACOIN project (the international exercise in which the results from various radionuclide-migration computer programs are compared). The model includes the effects of 1-D advection, dispersion, kinetic and/or equilibrium surface sorption, diffusion into the rock matrix with equilibrium bulk sorption and radioactive decay, and incorporates flexible input and output boundary conditions. It is evaluated by numerically inverting the analytical solution to the Laplace-transformed transport equations. Matrix diffusion was found to be the most important retardation mechanism for Np based on data reflecting the conditions at the Finnsjeeo site in east central Sweden. However, improved data and field testing are required to make the predictions of such models more reliable. (author)

  16. MARFA user's manual: Migration analysis of radionuclides in the far field

    International Nuclear Information System (INIS)

    Painter, S.; Mancillas, J.

    2013-12-01

    The computer code Migration Analysis of Radionuclides in the Far Field (MARFA) uses a particle-based Monte Carlo method to simulate the transport of radionuclides in a sparsely fractured geological medium. The algorithm uses non-interacting particles to represent packets of radionuclide mass. These particles are moved through the system according to rules that mimic the underlying physical transport and retention processes. The physical processes represented in MARFA include advection, longitudinal dispersion, Fickian diffusion into an infinite or finite rock matrix, equilibrium sorption, decay, and in-growth. Because the algorithm uses non-interacting particles, the transport and retention processes are limited to those that depend linearly on radionuclide concentration. Multiple non-branching decay chains of arbitrary length are supported, as is full heterogeneity in the transport and retention properties. Two variants of the code are provided. These two versions differ in how particles are routed through the computational domain. In MARFA 3.2.3, transport is assumed to occur along a set of trajectories or pathways that originate at radionuclide source locations. The trajectories are intended to represent the movement of hypothetical, advectively transported groundwater tracers and are typically calculated by pathline tracing in a discrete fracture network flow code. The groundwater speed and retention properties along each pathway may change in time, but the pathway trajectories are fixed. MARFA 3.3.1 allows the transport effects of changing flow directions to be represented by abandoning the fixed pathways and performing node routing within MARFA. (orig.)

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... medical test that helps physicians diagnose and treat medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ...

  18. Radiological characterisation and radon equilibrium factor in the outdoor air of a post-industrial urban area

    International Nuclear Information System (INIS)

    Rozas, S.; Idoeta, R.; Alegría, N.; Herranz, M.

    2016-01-01

    The radiological characterisation of outdoor air is always a complicated task due to the several radioactive emissions coming from the different radionuclides and also because of the very short half-lives of radionuclides in the natural radioactive series. In some places, this characterisation could result in unusual values because the natural presence of radionuclides with terrestrial origin can be modified by manmade activities. Nonetheless, this characterisation is useful not only for air quality control purposes but also because radon and its progeny in the outdoor air are the main contributors to human exposure from natural sources. In this study, we have carried out air particle sampling, followed by gamma-ray spectrometry, alpha spectrometry and beta counting determinations for this purpose. Subsequently, the outdoor air has been radiologically characterised through the obtained data and using a pre-existing analytical method to take into account the radioactive decays of short half-life radionuclides during sampling, sample preparation and measuring times. Bilbao was chosen to carry out this work. It is a medium-sized town located in northern Spain, close to the Atlantic Ocean and at sea level. This city has a recent industrial past as there were numerous steel mills and other heavy industries, including some quarries, and some open pit mines close to it, which concluded in a remediation program. So, it is a place where the air is potentially modified by manmade activities. The obtained results show that activity concentration values for long-lived radionuclides that precede radon and thoron are in the order of 10 −6  Bq m −3 and long-lived ones after radon are around 10 −4  Bq m −3 . Thoron progeny are around 2 × 10 −2  Bq m −3 and radon progeny are around 1.8 Bq m −3 . The mean radon equilibrium factor was 0.18. All of these values are close to the minimum UNSCEAR values, but show some variability, which highlights the importance

  19. Radionuclide toxicity

    International Nuclear Information System (INIS)

    Galle, P.

    1982-01-01

    The aim of this symposium was to review the radionuclide toxicity problems. Five topics were discussed: (1) natural and artificial radionuclides (origin, presence or emission in the environment, human irradiation); (2) environmental behaviour of radionuclides and transfer to man; (3) metabolism and toxicity of radionuclides (radioiodine, strontium, rare gas released from nuclear power plants, ruthenium-activation metals, rare earths, tritium, carbon 14, plutonium, americium, curium and einsteinium, neptunium, californium, uranium) cancerogenous effects of radon 222 and of its danghter products; (4) comparison of the hazards of various types of energy; (5) human epidemiology of radionuclide toxicity (bone cancer induction by radium, lung cancer induction by radon daughter products, liver cancer and leukaemia following the use of Thorotrast, thyroid cancer; other site of cancer induction by radionuclides) [fr

  20. Coronary CT angiography: Diagnostic value and clinical challenges.

    Science.gov (United States)

    Sabarudin, Akmal; Sun, Zhonghua

    2013-12-26

    Coronary computed tomography (CT) angiography has been increasingly used in the diagnosis of coronary artery disease due to improved spatial and temporal resolution with high diagnostic value being reported when compared to invasive coronary angiography. Diagnostic performance of coronary CT angiography has been significantly improved with the technological developments in multislice CT scanners from the early generation of 4-slice CT to the latest 320- slice CT scanners. Despite the promising diagnostic value, coronary CT angiography is still limited in some areas, such as inferior temporal resolution, motion-related artifacts and high false positive results due to severe calcification. The aim of this review is to present an overview of the technical developments of multislice CT and diagnostic value of coronary CT angiography in coronary artery disease based on different generations of multislice CT scanners. Prognostic value of coronary CT angiography in coronary artery disease is also discussed, while limitations and challenges of coronary CT angiography are highlighted.

  1. Superselective pseudo-continuous arterial spin labeling angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jensen-Kondering, Ulf [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Lindner, Thomas, E-mail: thomas.lindner@uksh.de [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Osch, Matthias J.P. van [C. J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden (Netherlands); Rohr, Axel; Jansen, Olav [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Helle, Michael [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Now with Philips GmbH Innovative Technologies, Research Laboratories, Hamburg (Germany)

    2015-09-15

    Highlights: • Superselective arterial spin labeling was capable of acquiring angiograms of individually selected arteries. • Image quality was similar compared with a routinely used time-of-flight angiography. • Superselective arterial spin labeling was utilized in patients with arterio-venous malformations and made it possible to visualize individual feeding vessels in a complete non-invasive way - Abstract: Purpose: To evaluate the utility of a novel non-contrast enhanced, vessel-selective magnetic resonance angiography (MRA) approach based on superselective pseudo-continuous arterial spin labeling (ASL) for the morphologic assessment of intracranial arteries when compared to a clinically used time-of-flight (TOF) MRA. Materials and methods: Three sets of selective ASL angiographies (right and left internal carotid artery, basilar artery) as well as one TOF data set were obtained from each of the five volunteers included in this study on a clinical 1.5T system. The depiction of arterial segments as well as their delineation was evaluated and independently analyzed by two radiologists. Additionally, the ASL angiography approach was performed in two patients suffering from arterio-venous malformations (AVM) in order to illustrate potential applications in a clinical setting. Results: In both angiography techniques, intracranial arteries and their segments (distal branches up to A5 segments of the anterior cerebral arteries, M8 segments of the middle cerebral arteries, and P5 segments of the posterior cerebral arteries) were continuously depicted with excellent inter-reader agreement (κ > 0.81). In AVM patients, reconstructed images of the TOF angiography presented similar information about the size and shape of the AVM as did superselective ASL angiography. In addition, the acquired ASL angiograms of selected vessels allowed assessing the blood supply of individually labeled arteries to the AVM which could also be confirmed by digital subtraction angiography

  2. Superselective pseudo-continuous arterial spin labeling angiography

    International Nuclear Information System (INIS)

    Jensen-Kondering, Ulf; Lindner, Thomas; Osch, Matthias J.P. van; Rohr, Axel; Jansen, Olav; Helle, Michael

    2015-01-01

    Highlights: • Superselective arterial spin labeling was capable of acquiring angiograms of individually selected arteries. • Image quality was similar compared with a routinely used time-of-flight angiography. • Superselective arterial spin labeling was utilized in patients with arterio-venous malformations and made it possible to visualize individual feeding vessels in a complete non-invasive way - Abstract: Purpose: To evaluate the utility of a novel non-contrast enhanced, vessel-selective magnetic resonance angiography (MRA) approach based on superselective pseudo-continuous arterial spin labeling (ASL) for the morphologic assessment of intracranial arteries when compared to a clinically used time-of-flight (TOF) MRA. Materials and methods: Three sets of selective ASL angiographies (right and left internal carotid artery, basilar artery) as well as one TOF data set were obtained from each of the five volunteers included in this study on a clinical 1.5T system. The depiction of arterial segments as well as their delineation was evaluated and independently analyzed by two radiologists. Additionally, the ASL angiography approach was performed in two patients suffering from arterio-venous malformations (AVM) in order to illustrate potential applications in a clinical setting. Results: In both angiography techniques, intracranial arteries and their segments (distal branches up to A5 segments of the anterior cerebral arteries, M8 segments of the middle cerebral arteries, and P5 segments of the posterior cerebral arteries) were continuously depicted with excellent inter-reader agreement (κ > 0.81). In AVM patients, reconstructed images of the TOF angiography presented similar information about the size and shape of the AVM as did superselective ASL angiography. In addition, the acquired ASL angiograms of selected vessels allowed assessing the blood supply of individually labeled arteries to the AVM which could also be confirmed by digital subtraction angiography

  3. Contrast-enhanced MR angiography in Leriche's syndrome

    International Nuclear Information System (INIS)

    Link, J.; Steffens, J.C.; Brossmann, J.; Heller, M.; Loose, R.

    1998-01-01

    Purpose: To determine the usefulness of contrast-enhanced MR angiography for the diagnosis of Leriche's syndrome. Material and methods: Leriche's syndrome was seen in 7 patients via DSA. In [dition, contrast-enhanced MR angiography was performed (T R 7.8 ms/T E 2.1 ms, flip angle 30 , slab thickness 116 mm, slice thickness 1.82 mm, 64 partitions, FOV 500x438 mm, matrix 224x512). Results: Diagnosis of Leriche's syndrome was possible by contrast-enhanced MR angiography in each case. Visualisation of the femoral arteries was not possible in two patients by intraarterial DSA, in three other patients there was an insufficient contrast in the femoral arteries with DSA. Contrast-enhanced MR angiography revealed good visualisation of the femoral arteries in these patients. In [dition, contrast-enhanced MR angiography allowed complete visualisation of the patent lower limb arteries. In intraarterial DSA visualisation of the lower limb arteries was achieved reached in only one patient, but was incomplete. Conclusion: Contrast-enhanced MR angiography yielded the correct diagnosis of Leriche's syndrome in all 7 patients. Contrast-enhanced MR angiography was superior to DSA in the assessment of the distal run-off vessels in five of seven patients. (orig.) [de

  4. Intraarterial digital subtraction angiography after coronary bypass surgery - an alternative to coronary angiography

    International Nuclear Information System (INIS)

    Hauenstein, H.K.; Roeren, T.; Schlosser, V.; Urbani, B.

    1985-01-01

    Intraarterial digital subtraction angiography after coronary bypass surgery - an alternative to coronary angiography. Intraarterial DSA is a suitable method for early postoperative control of coronary artery bypass grafts. Small quantities of contrast media with low iodine content are injected into the aortic root. Investigations can be carried out with a routine fluoroscopic and digital equipment; additional cine-technique and analogue memory disc are not necessary. At an image rate of 3/s the bypass anastomoses can be exactly visualized in 75%, whereas diagnostic information was not sufficient in only 4% of all cases. The use of modern F-5-catheters and the nonselective injection make this method a less invasive alternative to coronary angiography. It is paticularly useful in evaluation of short- and long-term results. (orig.) [de

  5. Mathematical Basis and Test Cases for Colloid-Facilitated Radionuclide Transport Modeling in GDSA-PFLOTRAN

    Energy Technology Data Exchange (ETDEWEB)

    Reimus, Paul William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-31

    This report provides documentation of the mathematical basis for a colloid-facilitated radionuclide transport modeling capability that can be incorporated into GDSA-PFLOTRAN. It also provides numerous test cases against which the modeling capability can be benchmarked once the model is implemented numerically in GDSA-PFLOTRAN. The test cases were run using a 1-D numerical model developed by the author, and the inputs and outputs from the 1-D model are provided in an electronic spreadsheet supplement to this report so that all cases can be reproduced in GDSA-PFLOTRAN, and the outputs can be directly compared with the 1-D model. The cases include examples of all potential scenarios in which colloid-facilitated transport could result in the accelerated transport of a radionuclide relative to its transport in the absence of colloids. Although it cannot be claimed that all the model features that are described in the mathematical basis were rigorously exercised in the test cases, the goal was to test the features that matter the most for colloid-facilitated transport; i.e., slow desorption of radionuclides from colloids, slow filtration of colloids, and equilibrium radionuclide partitioning to colloids that is strongly favored over partitioning to immobile surfaces, resulting in a substantial fraction of radionuclide mass being associated with mobile colloids.

  6. Symptomatic middle cerebral artery stenosis and occlusion. Comparison of three-dimensional time-of-flight magnetic resonance angiography with conventional angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, Motoshi; Yano, Hirohito; Shinoda, Jun; Funakoshi, Takashi [Daiyukai General Hospital, Ichinomiya, Aichi (Japan); Kumagai, Morio

    1994-10-01

    The usefulness of magnetic resonance (MR) angiography using the three-dimensional time-of-flight method for the characterization of symptomatic middle cerebral artery (MCA) occlusive lesions was evaluated in 10 patients with MCA occlusion and 10 with MCA stenosis. All lesions were symptomatic and documented by conventional angiography. There was no false-negative MR angiogram that failed to demonstrate the MCA occlusive lesion. MR angiography correctly evaluated the location of lesions and the difference between stenosis and occlusion. Stenosis appeared as a focal signal loss (<1.0cm) of the MCA at the site of stenosis, and occlusion as a complete signal loss of the MCA distal to the site of occlusion. However, MR angiography could not distinguish diffuse stenosis and one point stenosis demonstrated by conventional angiography. MR angiography is a useful noninvasive diagnostic method for evaluating occlusive lesions of the MCA in symptomatic patients. (author).

  7. Diagnostic and interventional angiography of superior mesenteric artery

    Energy Technology Data Exchange (ETDEWEB)

    Simonetti, G; Urigo, F; Canalis, G C; Guazzaroni, M; Caboni, M; Rossi, P; Passariello, R

    1986-01-01

    The widespread diffusion of digital imaging progressivaly reduces the indications to conventional angiography in all vascular districts. On the contrary, angiography of mesenteric arteries still works as a valid complementary diagnostic tool in granulomatous and neoplastic lesions of ileum. Today, in selected patients, angiography is the first diagnostic approach to vascular ischemic and hemorrhagic pathology of ileum; timely resort to interventional angiography improve a dramatic prognosis. 70 refs.

  8. Methods of separating short half-life radionuclides from a mixture of radionuclides

    International Nuclear Information System (INIS)

    Bray, L.A.; Ryan, J.L.

    1998-01-01

    The present invention is a method of obtaining a radionuclide product selected from the group consisting of 223 Ra and 225 Ac, from a radionuclide ''cow'' of 227 Ac or 229 Th respectively. The method comprises the steps of (a) permitting ingrowth of at least one radionuclide daughter from said radionuclide ''cow'' forming an ingrown mixture; (b) insuring that the ingrown mixture is a nitric acid ingrown mixture; (c) passing the nitric acid ingrown mixture through a first nitrate form ion exchange column which permits separating the ''cow'' from at least one radionuclide daughter; (d) insuring that the at least one radionuclide daughter contains the radionuclide product; (e) passing the at least one radionuclide daughter through a second ion exchange column and separating the at least one radionuclide daughter from the radionuclide product and (f) recycling the at least one radionuclide daughter by adding it to the ''cow''. In one embodiment the radionuclide ''cow'' is the 227 Ac, the at least one daughter radionuclide is a 227 Th and the product radionuclide is the 223 Ra and the first nitrate form ion exchange column passes the 227 Ac and retains the 227 Th. In another embodiment the radionuclide ''cow'' is the 229 Th, the at least one daughter radionuclide is a 225 Ra and said product radionuclide is the 225 Ac and the 225 Ac and nitrate form ion exchange column retains the 229 Th and passes the 225 Ra/Ac. 8 figs

  9. Prospective comparison of MR angiography and color duplex US with conventional angiography for peripheral arterial occlusive disease

    International Nuclear Information System (INIS)

    Mulligan, S.A.; Matsuda, T.; Lanzer, P.; Gross, G.; Routh, W.; Keller, F.; Koslin, D.B.; Berland, L.; Fields, M.; Doyle, M.; Cranney, G.; Lee, J.; Pohost, G.

    1990-01-01

    This paper evaluates color Doppler US (CDUS) and MR angiographic (MRA) assessment of peripheral vascular disease of the lower extremities, using blinded prospective comparison with conventional angiography. Conventional angiography, two-dimensional inflow MRA, and CDUS were performed in 12 patients. Four diagnostic categories were used to grade arterial lesions by evaluating peak velocity. Revascularization interventions were planned by the vascular surgeon, blinded from the imaging method utilized and from data derived from CDUS, MRA, and conventional angiography

  10. Hemifacial spasm; The value of vertebral angiography

    International Nuclear Information System (INIS)

    Yang, Hak Seok; Kim, Myung Soon; Han, Yong Pyo

    1992-01-01

    In order to evaluate the value of vertebral angiography in assesment of hemifacial spasm, We reviewed retrospectively the vertebral angiography of 28 patients (30 cases) with surgically proved hemifacial spasm but normal CT scans of posterior fossa. There were 9 males and 19 females. Angiography revealed vascular focus of hemifacial spasm located at anterior inferior cerebellar artery , posterior inferior cerebellar artery, and vertebral artery in 19, 9, and 2 cases respectively. Right side was involved in 20 cases. All involved vessels were elongated, tortuous, and dilated. In conclusion, vertebral angiography was valuable in evaluating hemifacial spasm of vascular origin in the posterior fossa

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... to your primary care or referring physician , who will discuss the results with you. top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need ...

  12. Breath-hold two-dimensional MR angiography of coronary arteries. Comparison with conventional coronary angiography in ten cases

    International Nuclear Information System (INIS)

    Li Liwei; Zhang Wanshi; Liu Chaozhong; Lu Xiaoyan; Xu Jiaxing

    1997-01-01

    Purpose: To assess the diagnostic value of two-dimensional coronary magnetic resonance (MR) angiography in patients evaluated for ischemic heart disease. Materials and methods: Ten patients who underwent selective cardiac catheterization with coronary MR angiography were evaluated with two-dimensional coronary MR angiography. Coronary MR angiography was performed with breath-hold fat-suppressed ECG-gated Turbo-FLASH with K-space segmentation using a 1.5 T imager. Results: The left main coronary artery, proximal left anterior descending artery, circumflex artery and right coronary artery were demonstrated in all cases. Continuous segments (mean) of left anterior descending, circumflex and right coronary arteries visualized on MRA were 6.72 +- 3.16 cm, 3.67 +- 4.81 cm and 7.93 +- 3.12 cm respectively. The overall sensitivity for detection of hemodynamically significant coronary artery lesion (≥50%) was 62.5% respectively. Conclusion: Breath-hold two-dimensional coronary MR angiography was useful in showing relatively long segments of the main coronary arteries and also has potential in depicting hemodynamically significant coronary artery lesions

  13. Methods of separating short half-life radionuclides from a mixture of radionuclides

    Science.gov (United States)

    Bray, Lane A.; Ryan, Jack L.

    1998-01-01

    The present invention is a method of obtaining a radionuclide product selected from the group consisting of .sup.223 Ra and .sup.225 Ac, from a radionuclide "cow" of .sup.227 Ac or .sup.229 Th respectively. The method comprises the steps of a) permitting ingrowth of at least one radionuclide daughter from said radionuclide "cow" forming an ingrown mixture; b) insuring that the ingrown mixture is a nitric acid ingrown mixture; c) passing the nitric acid ingrown mixture through a first nitrate form ion exchange column which permits separating the "cow" from at least one radionuclide daughter; d) insuring that the at least one radionuclide daughter contains the radionuclide product; e) passing the at least one radionuclide daughter through a second ion exchange column and separating the at least one radionuclide daughter from the radionuclide product and f) recycling the at least one radionuclide daughter by adding it to the "cow". In one embodiment the radionuclide "cow" is the .sup.227 Ac, the at least one daughter radionuclide is a .sup.227 Th and the product radionuclide is the .sup.223 Ra and the first nitrate form ion exchange column passes the .sup.227 Ac and retains the .sup.227 Th. In another embodiment the radionuclide "cow"is the .sup.229 Th, the at least one daughter radionuclide is a .sup.225 Ra and said product radionuclide is the .sup.225 Ac and the .sup.225 Ac and nitrate form ion exchange column retains the .sup.229 Th and passes the .sup.225 Ra/Ac.

  14. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  15. Digital subtraction angiography for breast cancer

    International Nuclear Information System (INIS)

    Tsurumi, Kiyohiko; Okuyama, Nobuo

    1987-01-01

    We performed digital subtraction angiography (DSA) on 42 patients with breast diseases to investigate its efficiency. As a result we came to the following conclusions: 1. The sensitivity was well evaluated in intraarterial digital subtraction angiography (IA-DSA) of breast. 2. IA-DSA could diagnose difficult cases like cancer which had undergone augmentation mammoplasty, or like Paget's disease and others. 3. DSA was a safe examination method. 4. The sensitivity of IA-DSA of breast cancer is superior to intravenous digital subtraction angiography (IV-DSA). (author)

  16. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography ...

  17. Latest techniques in head and neck CT angiography

    International Nuclear Information System (INIS)

    Schuknecht, B.

    2004-01-01

    Continuous evolution of multi row CT is increasingly making CT angiography a viable imaging modality for assessment of the supraaortic and intracranial vessels as an anatomically and functionally coherent vascular system. Extended non-invasive examinations with reduced contrast volume have become feasible with the availability of 16 and 64 row MDCT scanners. Prerequisites to obtain high resolution CT angiographies of the head and neck vessels with superior detail include the administration of low contrast volume, high contrast density (400 mg I/ml) contrast media, adequate timing and data acquisition, optimal flow rate (4 ml/s) and saline flushing. Non-invasiveness, delineation of vessel calcification, virtual independence from hemodynamic conditions, and the ability to provide quantification without needing to correct for magnification are all attributes that favour CT angiography over digital subtraction angiography and to some extent even magnetic resonance angiography as an alternative non-invasive technique. CT angiography is established as a modality of choice for the assessment of patients with acute stroke and chronic steno-occlusive disease. CT angiography may indicate the presence of extra- or intracranial acute vessel occlusion and dissection, predisposing atherosclerotic steno-occlusive disease and thus indicate thrombo-embolism or local appositional thrombosis as the principle pathogenic factor. CT angiography is used to assess anatomy, and to depict the presence, location and extent of calcified and non-calcified plaque as a cause of high grade stenosis. Despite relatively limited sensitivity CT angiography is indicated for suspected or confirmed aneurysms that demand further verification of their presence, geometry, or relationship to parent artery branches and osseous anatomic landmarks. Low volume high density contrast media have substantially increased the ability of CT angiography to depict small aneurysms, small branches, and collateral vessels

  18. Acute coronary care: Principles and practice

    International Nuclear Information System (INIS)

    Califf, R.M.; Wagner, G.S.

    1985-01-01

    This book contains 58 chapters. Some of the chapter titles are: Radionuclide Techniques for Diagnosing and Sizing of Myocardial Infarction; The Use of Serial Radionuclide Angiography for Monitoring Function during Acute Myocardial Infarction; Hemodynamic Monitoring in Acute Myocardial Infarction; and The Valve of Radionuclide Angiography for Risk Assessment of Patients following Acute Myocardial Infarction

  19. Physical and chemical factors influencing radionuclide behaviour in arable soils

    International Nuclear Information System (INIS)

    Rauret, G.; Vidal, M.; Alexakhin, R.M.; Kruglov, S.V.; Cremers, A.; Wauters, J.; Valcke, E.; Ivanov, Y.

    1996-01-01

    Soil-to-plant transfer of radionuclides integrates plant physiological and soil chemical aspects. Therefore, it is necessary to study the factors affecting the equilibrium of the radionuclides between solid and soil solution phases. Desorption and adsorption studies were applied to the podsolic and peat soils considered in the ECP-2 project. In the desorption approach, both sequential extraction and 'infinite bath' techniques were used. In the adsorption approach, efforts were directed at predicting Cs and Sr-K D on the basis of soil properties and soil solution composition. Desorption approach predicts time-dynamics of transfer with time but it is un sufficient for comparatively predicting transfer. Adsorption studies informs about which are the key factors affecting radionuclide transfer. For Sr, availability depends on the CEC and on the concentration of the Ca + Mg in the soil solution. For Cs, availability is mainly dependent on the partitioning between FES -frayed edge sites-, which are highly specific and REC -regular exchange complex-, with low selectivity for Cs. Moreover, availability depends on the K and NH 4 , levels in the soil solution and fixation properties of the soil. Considering these factors, the calculation of the in situ K D values helps to predict the relative transfer of radionuclides. The calculation of the K D of the materials that could be used as countermeasures could permit the prediction of its suitability to decrease transfer and therefore to help in producing cleaner agricultural products

  20. Angiography in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Zeitler, E

    1982-04-05

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology.

  1. Magnetic resonance angiography for the head and neck region

    International Nuclear Information System (INIS)

    Aschenbach, R.; Esser, D.

    2004-01-01

    Magnetic resonance angiography is a noninvasive method in vascular imaging using noncontrast- enhanced and contrast-enhanced techniques. The contrast media used in contrast- enhanced magnetic resonance angiography are different from the X-ray contrast media and do not affect the thyroid gland or renal function. In detecting hypervascularized lesions in the head and neck, contrast-enhanced magnetic resonance angiography is the method of choice, which provides an acceptable quality in comparison to digital subtraction angiography. Future developments in magnetic resonance imaging techniques will cause a wider use of magnetic resonance angiography, especially in head and neck imaging. Digital subtraction angiography should therefore only be used in problem cases and for preoperative embolization [de

  2. Angiography and interventional radiology of the kidneys; Angiographie und interventionelle Radiologie der Nieren

    Energy Technology Data Exchange (ETDEWEB)

    Hansmann, J.; Richter, G.M.; Hallscheidt, P.; Duex, M.; Noeldge, G.; Kaufmann, G.W. [Heidelberg Univ. (Germany). Abt. Radiodiagnostik

    1999-05-01

    For imaging of renal pathology a broad spectrum of radiologic diagnostic procedures are available which are, sometimes and particularly more recently, competing among each other in their diagnostic yield and relevance. For tumorous lesions ultrasound, computed tomography and magnetic resonance imaging are performed predominantly. Angiography is no longer required with the exception of highly selected cases and in some specific preoperative workup requirements. Until recently, catheter based digital subtraction angiography has been considered as gold standard. However, non-invasive techniques such as CT-angiography and MR-angiography are evolving parallel to their quantum leap of resolutions and readiness to use. Nevertheless, well accepted criteria for quality assessement of these new modalities are still lacking. More comparison studies are urgently warranted. Despite the availability of ultrashort pulse sequences applying the T1 relaxation reduction effect of gadolinium enhanced MR techniques overestimation of renal artery stenosis still poses a substantial problem. Renal intervention implies a variety of procedures such as plain angioplasty, stent placement, embolization of traumatic and both benign and malignant tumors. These methods have emerged over the last two decades from a more experimental nature to a fully accepted treatment option. When renal artery angioplasty is embedded in an aggressive approach including stenting as an adjunct for more complex cases, renal ostial lesions and a well organized follow-up regimen its therapeutic potential for treatment of renal insufficiency, malignant hypertension, for organ preservation bears a very high potential. Provided adequate periinterventional drug regimen restenosis rates may be as low as 10%. In highly selected cases capillary embolization might be used as an alternative to nephrectomy with a similar clinical outcome. Particularly the development of superselective small caliber embolization catheters

  3. Comparison of CO2 DSA and conventional angiography using non-ionic contrast media in lower extremity angiography

    International Nuclear Information System (INIS)

    Kim, Jae Kyu; Park, Sung Jae; Koh, Seok Wan; Seo, Jeong Jin; Kang, Heoung Keun; Chung, Hyon De

    1994-01-01

    The purpose of this study is to compare CO 2 DSA and nonionic contrast media angiography in respect to the quality of the opacification of collaterals and incidence of side-effects in peripheral occlusive arterial disease. Sixteen patients who were suspected to have peripheral occlusive arterial disease were performed angiography with nonionic contrast media and CO 2 at the same location with the same catheter. The causes of the lesions were atherosclerosis(n=7) and Buerger's disease(n=9). CO 2 DSA was compared with nonionic contrast media angiography in respect to the quality of image in the diagnosis of the lesions, opacifications of collaterals and side-effects. In atherosclerosis; quality of the images of CO 2 DSA was same as that of nonionic contrast media angiography in 6 patients and was poor in 1 patient; opacifications of collaterals of CO 2 DSA were same as that of nonionic contrast media angiography in 5 patients and was poor in 2 patients. In Buerger's disease; quality of the images of CO 2 DSA was same as that of nonionic contrast media angiography in 2 patients and was poor in 7 patients; opacifications of collaterals of CO 2 DSA were same as that of nonionic contrast media angiography in 1 patient and was poor in 8 patients. Leg pain was the only side-effect after CO 2 injection occurring in 4 out of 16 patients. CO 2 could be used as safe contrast media in patient with risk factors for nonionic contrast media and for diagnosis of the atherosclerosis in lower extremity. For the procedures such as vascular intervention requiring large amount of contrast media CO 2 could effectively replace nonionic contrast media

  4. Videodensitometric quantitative angiography after coronary balloon angioplasty, compared to edge-detection quantitative angiography and intracoronary ultrasound imaging

    NARCIS (Netherlands)

    Peters, R. J.; Kok, W. E.; Pasterkamp, G.; von Birgelen, C.; Prins, M. [=Martin H.; Serruys, P. W.

    2000-01-01

    AIMS: To assess the value of videodensitometric quantification of the coronary lumen after angioplasty by comparison to two other techniques of coronary artery lumen quantification. METHODS AND RESULTS: Videodensitometric quantitative angiography, edge detection quantitative angiography and 30 MHz

  5. Radionuclide trap

    International Nuclear Information System (INIS)

    McGuire, J.C.

    1978-01-01

    The deposition of radionuclides manganese-54, cobalt-58 and cobalt-60 from liquid sodium coolant is controlled by providing surfaces of nickel or high nickel alloys to extract the radionuclides from the liquid sodium, and by providing surfaces of tungsten, molybdenum or tantalum to prevent or retard radionuclide deposition

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... congenital abnormalities in blood vessels, especially arteries in children (e.g., malformations in the heart or other ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an artery ... examined, a contrast material is injected through the tube and images are captured using a small dose ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... accurate pictures of the blood vessels and may eliminate the need for surgery. Tell your doctor if ... are the benefits vs. risks? Benefits Angiography may eliminate the need for surgery. If surgery remains necessary, ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... angiogram may be performed in less than an hour; however, it may last several hours. top of ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... a tendency to bleed. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... diagnosis and treatment in a single procedure. An example is finding an area of severe arterial narrowing, ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... possible to combine diagnosis and treatment in a single procedure. Catheter angiography produces very detailed, clear and ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... blood flow to the brain and cause a stroke. identify a small aneurysm or arteriovenous malformation (abnormal ... you. top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need for ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... iodine. If angiography is essential, a variety of methods is used to decrease risk of allergy: You ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. Catheter angiography ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. An example ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... examine blood vessels in key areas of the body for abnormalities such as aneurysms and disease such ... to produce pictures of blood vessels in the body. Angiography is performed using: x-rays with catheters ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... rare, and radiology departments are well-equipped to deal with them. There is a small risk that ... standard x-ray contrast. Catheter angiography should be done very cautiously—if at all—in patients who ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... possible charges you will incur. Web page review process: This Web page is reviewed regularly by a ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... few millimeters) in the skin where the catheter can be inserted into an artery. The catheter is ... need for surgery. If surgery remains necessary, it can be performed more accurately. Catheter angiography presents a ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... 20 minutes (or by using a special closure device). When the examination is complete, you may be ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... rays ). top of page What are some common uses of the procedure? Catheter angiography is used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... and x-rays. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material to examine ... removable dental appliances, eye glasses and any metal objects or clothing that might interfere with the x- ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... American College of Radiology (ACR) and the European Society of Urogenital Radiology note that the available data ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... most cases, the kidneys will regain their normal function within five to seven days. Rarely, the catheter ... limitations of Catheter Angiography? Patients with impaired kidney function, especially those who also have diabetes, are not ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... in key areas of the body, including the: brain neck heart chest abdomen (such as the kidneys ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... The video is produced by the x-ray machine and a detector that is suspended over a ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need for surgery. ... in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... serious allergic reaction to contrast materials that contain iodine is extremely rare, and radiology departments are well- ... having a reaction to contrast materials that contain iodine. If angiography is essential, a variety of methods ...

  12. Angiography in portal hypertension

    International Nuclear Information System (INIS)

    Zeitler, E.

    1982-01-01

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology. (orig.) [de

  13. Magnetic resonance angiography of arteriovenous malformation in the brainstem

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Hirofumi; Kida, Yoshihisa; Kobayashi, Tatsuya; Tanaka, Takayuki; Iwakoshi, Takayasu; Kai, Osamu; Hirose, Mitsuhiko [Komaki City Hospital, Aichi (Japan)

    1993-11-01

    The magnetic resonance (MR) angiography appearance of arteriovenous malformation (AVM) in the tegmentum and pons is described. The interpeduncular perforating branches of the posterior cerebral artery and median pontine branches of the basilar artery were seen more clearly by MR angiography than by conventional angiography. MR angiography was very useful for the follow-up of AVM after stereotactic radiosurgery. (author).

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Contrast Materials CT Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  16. Radionuclide cisternography

    International Nuclear Information System (INIS)

    Song, H.H.

    1980-01-01

    The purpose of this thesis is to show that radionuclide cisternography makes an essential contribution to the investigation of cerebrospinal fluid (CSF) dynamics, especially for the investigation of hydrocephalus. The technical details of radionuclide cisternography are discussed, followed by a description of the normal and abnormal radionuclide cisternograms. The dynamics of CFS by means of radionuclide cisternography were examined in 188 patients in whom some kind of hydrocephalus was suspected. This study included findings of anomalies associated with hydrocephalus in a number of cases, such as nasal liquorrhea, hygromas, leptomeningeal or porencephalic cysts. The investigation substantiates the value of radionuclide cisternography in the diagnosis of disturbances of CSF flow. The retrograde flow of radiopharmaceutical into the ventricular system (ventricular reflux) is an abnormal phenomenon indicating the presence of communicating hydrocephalus. (Auth.)

  17. Rest and exercise ventricular function in adults with congenital ventricular septal defects

    International Nuclear Information System (INIS)

    Jablonsky, G.; Hilton, J.D.; Liu, P.P.; Morch, J.E.; Druck, M.N.; Bar-Shlomo, B.Z.; McLaughlin, P.R.

    1983-01-01

    Rest and exercise right and left ventricular function were compared using equilibrium gated radionuclide angiography in 19 normal sedentary control subjects and 34 patients with hemodynamically documented congenital ventricular septal defect (VSD). Gated radionuclide angiography was performed at rest and during each level of graded supine bicycle exercise to fatigue. Heart rate, blood pressure, maximal work load achieved, and right and left ventricular ejection fractions were assessed. The control subjects demonstrated an increase in both the left and right ventricular ejection fractions with exercise. All study groups failed to demonstrate an increase in ejection fraction in either ventricle with exercise. Furthermore, resting left ventricular ejection fraction in Groups 2 and 3 was lower than that in the control subjects and resting right ventricular ejection fraction was lower in Group 3 versus control subjects. Thus left and right ventricular function on exercise were abnormal in patients with residual VSD as compared with control subjects; rest and exercise left ventricular ejection fractions remained abnormal despite surgical closure of VSD in the remote past; resting left and right ventricular function was abnormal in patients with Eisenmenger's complex; lifelong volume overload may be detrimental to myocardial function

  18. Three-Dimensional Respiratory-Gated Coronary Mr Angiography with Reference to X-Ray Coronary Angiography

    International Nuclear Information System (INIS)

    Ikonen, A. E. J.; Manninen, H. I.; Vainio, P.; Vanninen, R. L.; Matsi, P. J.; Soimakallio, S.; Hirvonen, T.P.J.; Hartikainen, J.E.K.

    2003-01-01

    Purpose: To assess the clinical value of three-dimensional coronary MR angiography (CMRA) in the detection of significant coronary artery stenosis using conventional X-ray angiography as the standard reference. Material and Methods: Sixty-nine patients underwent X-ray coronary angiography and CMRA because of suspected or previously diagnosed coronary artery disease. MRI was performed with a 1.5-T whole body imaging system using ECG-triggered 3D gradient echo sequence with retrospective navigator echo respiratory gating and fat suppression. Results: A total of 276 coronary artery segments were analyzed. The X-ray coronary angiography was normal in 22 patients. Significant proximal stenoses (exceeding 50%) or occlusions were present in 102 coronary artery segments. In all, 120 stenoses or occlusions were identified in CMRA. Sixteen percent of the coronary artery segments had to be excluded because of poor image quality. The overall sensitivity and specificity for MRA for identification of significant stenosis were 75% and 62%, respectively. CMRA correctly detected 89% of patients with at least one vessel disease, but 6 patients with coronary artery disease would have been missed. Conclusions: Because of the high data exclusion and false-negative case rate, CMRA with retrospective navigator echo triggering is at present not suitable as a clinical screening method in coronary artery disease

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... with you. top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need for surgery. If ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  20. The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography

    International Nuclear Information System (INIS)

    Schueltke, E.; Fiedler, S.; Kelly, M.; Griebel, R.; Juurlink, B.; LeDuc, G.; Esteve, F.; Le Bas, J.-F.; Renier, M.; Nemoz, C.; Meguro, K.

    2005-01-01

    Background: Catheterization of small-caliber blood vessels in the central nervous system can be extremely challenging. Alternatively, intravenous (i.v.) administration of contrast agent is minimally invasive and therefore carries a much lower risk for the patient. With conventional X-ray equipment, volumes of contrast agent that could be safely administered to the patient do not allow acquisition of high-quality images after i.v. injection, because the contrast bolus is extremely diluted by passage through the heart. However, synchrotron-based digital K-edge subtraction angiography does allow acquisition of high-quality images after i.v. administration of relatively small doses of contrast agent. Materials and methods: Eight adult male New Zealand rabbits were used for our experiments. Animals were submitted to both angiography with conventional X-ray equipment and synchrotron-based digital subtraction angiography. Results: With conventional X-ray equipment, no contrast was seen in either cerebral or spinal blood vessels after i.v. injection of iodinated contrast agent. However, using K-edge digital subtraction angiography, as little as 1 ml iodinated contrast agent, when administered as i.v. bolus, yielded images of small-caliber blood vessels in the central nervous system (both brain and spinal cord). Conclusions: If it would be possible to image blood vessels of the same diameter in the central nervous system of human patients, the synchrotron-based technique could yield high-quality images at a significantly lower risk for the patient than conventional X-ray imaging. Images could be acquired where catheterization of feeding blood vessels has proven impossible

  1. Magnetic resonance angiography for patients with positional vertigo

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Toru; Tominaga, Satoru; Fujiki, Hiroya (Takarazuka City Hospital, Hyogo (Japan)); Kumoi, Takeo

    1993-11-01

    Magnetic resonance angiography (MRA) can image the blood vessels without invasion. Using MRA, we studied the vascular morphology of the vertebral artery in patients with positional nystagmus and vertigo. Fifteen patients without vestibular disorder such as benign positional vertigo were examined. Six cases underwent conventional vertebral angiography, including digital subtraction angiography (DSA) for comparison with MRA. In all cases. we observed the vertebral artery from the bifurcation to the basilar artery with MRA. In 12 cases, abnormal findings of elongation, bending, narrowing or obstruction of the vertebral artery were found. In five cases, arterial compression and elongation increased in association with head rotation. A difference in the vessel diameter on each side was observed in 4 cases. Accordingly, some abnormal vessels were found in 14 of 15 cases in our study. This rate was very close to previous results obtained with conventional angiography. In two cases, MRA findings differed from conventional angiography due to peculiar artifacts of MRA. Therefore, MRA may be the first choice for the patients with vertigo, followed by conventional angiography, if necessary. (author).

  2. Magnetic resonance angiography for patients with positional vertigo

    International Nuclear Information System (INIS)

    Seo, Toru; Tominaga, Satoru; Fujiki, Hiroya; Kumoi, Takeo.

    1993-01-01

    Magnetic resonance angiography (MRA) can image the blood vessels without invasion. Using MRA, we studied the vascular morphology of the vertebral artery in patients with positional nystagmus and vertigo. Fifteen patients without vestibular disorder such as benign positional vertigo were examined. Six cases underwent conventional vertebral angiography, including digital subtraction angiography (DSA) for comparison with MRA. In all cases. we observed the vertebral artery from the bifurcation to the basilar artery with MRA. In 12 cases, abnormal findings of elongation, bending, narrowing or obstruction of the vertebral artery were found. In five cases, arterial compression and elongation increased in association with head rotation. A difference in the vessel diameter on each side was observed in 4 cases. Accordingly, some abnormal vessels were found in 14 of 15 cases in our study. This rate was very close to previous results obtained with conventional angiography. In two cases, MRA findings differed from conventional angiography due to peculiar artifacts of MRA. Therefore, MRA may be the first choice for the patients with vertigo, followed by conventional angiography, if necessary. (author)

  3. On the system of cine-angiography

    International Nuclear Information System (INIS)

    Wakamatsu, Koji; Togi, Hideaki; Yokoyama, Hironori

    1979-01-01

    National Institute of Circulatory Disease Centre have four angiography apparatuses which deal with more than 80 cases of cerebral blood vessel and 100 cases of heart blood vessel each month. Most of the angiography is cine-photography. Five more angiography apparatuses are expected to be operated in operation and RI examination rooms in the future. The problems on cine-angiography system were discussed as follows: (1) The proper dose must be chosen in order to obtain good quality of cine-images. (2) The cine resolution depends much on dose. (3) The lower X-ray tube voltage can give better contrast. (4) Suitable capacity for an X-ray tube is over 60 kW at 2 sec rating. (5) Cine-autophotography requires rapid response and a circuit for lock. (6) Influence of side scattering can be solved by a blanking circuit in biplane cine-photography. (7) Self-developing is desirable to improve the quality of cine-images. (Kobatake, H.)

  4. Comparison of spiral CT angiography with conventional digital subtraction angiography in the evaluation of renal transplant donors: a pilot study

    International Nuclear Information System (INIS)

    Chu, C.; Young, N.; Lau, H.

    2001-01-01

    Conventional digital subtraction renal arteriography (IA-DSA) has been traditionally used as the preoperative imaging modality for assessment of renal vascular anatomy for renal transplant donors. This study evaluates the potential use of spiral CT angiography in replacing IA-DSA in the preoperative assessment of this group of patients. Seven patients underwent both spiral CT angiography and IA-DSA between October 1997 and April 1998. It is concluded that spiral CT angiography can demonstrate the number, length and location of renal arteries and it is suggested that spiral CT angiography can potentially replace IA-DSA in the preoperative assessment of renal donors. Copyright (2001) Blackwell Science Pty Ltd

  5. Inter-comparison of dynamic models for radionuclide transfer to marine biota in a Fukushima accident scenario

    Energy Technology Data Exchange (ETDEWEB)

    Vives i Batlle, J.; Beresford, N. A.; Beaugelin-Seiller, K.; Bezhenar, R.; Brown, J.; Cheng, J. -J.; Ćujić, M.; Dragović, S.; Duffa, C.; Fiévet, B.; Hosseini, A.; Jung, K. T.; Kamboj, S.; Keum, D. -K.; Kryshev, A.; LePoire, D.; Maderich, V.; Min, B. -I.; Periáñez, R.; Sazykina, T.; Suh, K. -S.; Yu, C.; Wang, C.; Heling, R.

    2016-03-01

    We report an inter-comparison of eight models designed to predict the radiological exposure of radionuclides in marine biota. The models were required to simulate dynamically the uptake and turnover of radionuclides by marine organisms. Model predictions of radionuclide uptake and turnover using kinetic calculations based on biological half-life (TB1/2) and/or more complex metabolic modelling approaches were used to predict activity concentrations and, consequently, dose rates of 90Sr, 131I and 137Cs to fish, crustaceans, macroalgae and molluscs under circumstances where the water concentrations are changing with time. For comparison, the ERICA Tool, a model commonly used in environmental assessment, and which uses equilibrium concentration ratios, was also used. As input to the models we used hydrodynamic forecasts of water and sediment activity concentrations using a simulated scenario reflecting the Fukushima accident releases. Although model variability is important, the intercomparison gives logical results, in that the dynamic models predict consistently a pattern of delayed rise of activity concentration in biota and slow decline instead of the instantaneous equilibrium with the activity concentration in seawater predicted by the ERICA Tool. The differences between ERICA and the dynamic models increase the shorter the TB1/2 becomes; however, there is significant variability between models, underpinned by parameter and methodological differences between them. The need to validate the dynamic models used in this intercomparison has been highlighted, particularly in regards to optimisation of the model biokinetic parameters.

  6. Complications with Outpatient Angiography and Interventional Procedures

    International Nuclear Information System (INIS)

    Young, Noel; Chi, Ka-Kit; Ajaka, Joe; McKay, Lesa; O'Neill, Diane; Wong, Kai Ping

    2002-01-01

    Purpose: To prospectively identify the complications, and rates of complication, in outpatient angiography and interventional procedures. Methods: There were 1050 consecutive patients, 646 men and 404 women, aged 17-89 years, with a total of 1239 procedures studied in a 2-year period, 1997 to 1999. Results: There were 560 cases of aorto-femoral angiography,resulting in 124 complications (22%), with pain or hematoma in 110.There were 206 cases of neck and cerebral angiography, resulting in 51 complications (25%), with pain and hematoma in 34, transient ischemic attack in 2 and cerebrovascular accident in 1. There were 197 interfentional procedures, with 177 being balloon dilatations, resulting in 68 complications (35%), with 2 having hematomas and 1 having hematoma/abscess requiring active treatment. There were 276 cases having various 'other' procedures (e.g., renal angiography),resulting in 65 complications (24%), with pain and hematoma in 61. No procedure-related death occurred. Eighteen cases (1.5%) had significant complications, with contrast allergy in eight. Conclusion: Outpatient angiography and intervention are relatively safe, with low significant complication rates

  7. Preoperative cerebral aneurysm assessment by three-dimensional CT angiography. Feasibility of surgery without cerebral angiography

    International Nuclear Information System (INIS)

    Kashiwagi, Shiro; Yamashita, Katsuhiro; Kato, Shoichi; Ito, Haruhide; Kurokawa, Kensuke; Watanabe, Yutaka

    1999-01-01

    The purpose of this study is to assess the capability of three-dimensional CT angiography (3D-CTA) to replace conventional catheter angiography as a preoperative examination for unruptured intracranial aneurysms. A prospective study was designed to evaluate 18 patients with 20 unruptured intracranial aneurysms (13 middle cerebral artery aneurysms, 6 anterior communicating artery aneurysms, and 1 internal carotid posterior communicating artery aneurysm) who underwent surgery. There were 12 women and 6 men with the average age of 63 years old. All patients were initially diagnosed as having intracranial aneurysms by MR angiography, followed by 3D-CTA and conventional catheter angiography for confirmation. Three experienced neurosurgeons were in charge of the operations. One of the neurosurgeons (surgeon 1) was provided with only 3D-CTA as the preoperative radiological evaluation, while the others (surgeon 2 and 3) were given through assessments with MRA, 3D-CTA, and conventional angiography. Surgeon 1 carried out the operations under careful observation by the surgeons 2 and 3. Problems encountered by the surgeon 1 during surgery were recorded. Neck clipping in 19 aneurysms and dome wrapping in 1 were successfully accomplished. All patients were discharged without complication. Surgeries went smoothly in 16 aneurysms with 3D-CTA alone. Discrepancies between the 3D-CTA findings and microsurgical anatomy were noted in 4 aneurysms: the size of the neck was overestimated in 3 aneurysms, the relationships to parent arteries were obscure in 2 aneurysms, and a perforating artery problematic to neck clipping was missed in 1 aneurysms by 3D-CTA. The results of this study support the notion that 3D-CTA can replace conventional catheter angiography as preoperative examination in the majority of regular-sized anterior circulation aneurysms. Nevertheless, surgeons should recognize and be prepared for the fact that 3D-CTA can give false impression about the aneurysm neck and

  8. A sensitive and quantitative biosensing method for the determination of γ-ray emitting radionuclides in surface water

    International Nuclear Information System (INIS)

    Wolterbeek, H.Th.; Meer, A.J.G.M. van der

    1996-01-01

    A quantitative and sensitive biosensing method has been developed for the determination of γ-ray emitting radionuclides in surface water. The method is based on the concept that at equilibrium the specific radioactivity in the biosensor is equal to the specific radioactivity in water. The method consists of the measurement of both the radionuclide and the element in the biosensor and the determination of the element level in water. This three-way analysis eliminates problems such as unpredictable biosensor behaviour, effects of water elemental composition or further abiotic parameters: what remains is the generally high enrichment (bioaccumulation factor BCF) of elements and radionuclides in the biosensor material. Measurements were performed with floating water plants (Azolla filiculoides Lamk., Spirodela polyrhiza/Lemna sp.) and the fully submerged water plant Ceratophyllum demersum L., which were sampled from ditch water. Concentrations of elements and radionuclides were determined in both water and biosensor plants, using Neutron Activation Analysis (NAA), ICP-MS, and γ-ray spectrometry, respectively. For the latter, both 1 litre samples (Marinelli-geometry) and 1 cm 3 samples (well-type detectors) were applied in measurements. (author)

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... about radiology? Share your patient story here Images × ... Related Articles and Media Angioplasty and Vascular Stenting MR Angiography (MRA) Contrast ...

  10. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography.

    Science.gov (United States)

    Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... the equipment look like? How does the procedure work? How is the ... and treat medical conditions. Angiography uses one of three imaging technologies and, ...

  12. The isolation of water-soluble radionuclides from deteriorating spent nuclear fuel in zeolite cartridge

    International Nuclear Information System (INIS)

    Hassan, N.M.; Thompson, M.C.

    1996-01-01

    A method of isolating water-soluble radionuclides leaching from deteriorating spent nuclear fuel by ion-exchange in zeolite cartridges has been studied. Design calculations of two zeolite cartridges to be incorporated in typical spent fuel storage bundle have been provided. Equilibrium exchange data obtained at several temperatures have shown that the maximum exchange capacity of total cesium in sodium titanium aluminosilicate was 114 mg/g zeolite and the capacity at 95% exchange for radioactive isotope Cs-137 was calculated as 55.2 mg/g zeolite. The kinetic data suggest that the rate of exchange of Cs + in sodium titanium aluminosilicate zeolite takes place by a fast initial exchange step followed by slow diffusion of cesium cations. Design calculations based on the equilibrium exchange data show that water-soluble radionuclides leaching from Mk 31 slugs can be isolated using two zeolite cartridges, each 3.7 inches in inside diameter and 2.5 inches in length. The cartridges are designed to isolate 95% of the Cs + leaching from the spent fuel storage bundle. The results from the thermal induced convective flow tests indicate that the system will provide necessary cooling to the spent fuel by convective currents while isolating the Cs + leaching from spent fuel storage bundle in the cartridges

  13. Radionuclide diagnostics of right ventricle

    International Nuclear Information System (INIS)

    Zaorska-Rajca, J.

    1993-01-01

    Difficulties in evaluating the right ventricle function motivate to making research into new non-invasive methods. Four radionuclide methods that are used to access the right ventricle have been discussed in this paper: first-pass angiocardiography, gated equilibrium ventriculography with red blood cells labelled in vivo technetium- 99 Tc, ventriculography with radioactive xenon 133 and a computerized single probe. Advantages and disadvantages of using each method have been discussed. RNV 99m Tc method has been recognized as the best one to evaluate RV function. Results of the right ventricle assessment in patients have been discussed in the following clinical groups: chronic cor pulmonale (CP), chronic lung disease without pulmonary arterial hypertension (LD), coronary artery disease (CAD), in patients after infarction (IMA and IMi), dilated cardiomyopathy (KZ) and valvular heart diseases (Wm and Wa). Abnormals in right ventricle function occur with different intensity in all groups, although they no specificity. The highest abnormality occurs in patients with KZ, CP, IMi and Wm, the lowest one - in patients with CAD. Abnormalities are higher in patients with congestive heart failure. In most pathological groups the right ventricle dysfunction is connected with the left ventricle insufficiency. The interdependence between the dysfunction of both ventricles is differs in particular diseases. Assessment of right ventricle function with radionuclide methods plays an important role in diagnosis and control therapy of cardiopulmonary diseases. (author). 385 refs, 48 figs, 6 tabs

  14. A comparison between magnetic resonance angiography at 3 teslas (time-of-flight and contrast-enhanced and flat-panel digital subtraction angiography in the assessment of embolized brain aneurysms

    Directory of Open Access Journals (Sweden)

    Guilherme S. Nakiri

    2011-01-01

    Full Text Available PURPOSE: To compare the time-of-flight and contrast-enhanced- magnetic resonance angiography techniques in a 3 Tesla magnetic resonance unit with digital subtraction angiography with the latest flat-panel technology and 3D reconstruction in the evaluation of embolized cerebral aneurysms. INTRODUCTION: Many embolized aneurysms are subject to a recurrence of intra-aneurismal filling. Traditionally, imaging surveillance of coiled aneurysms has consisted of repeated digital subtraction angiography. However, this method has a small but significant risk of neurological complications, and many authors have advocated the use of noninvasive imaging methods for the surveillance of embolized aneurysms. METHODS: Forty-three aneurysms in 30 patients were studied consecutively between November 2009 and May 2010. Two interventional neuroradiologists rated the time-of-flight-magnetic resonance angiography, the contrast-enhanced-magnetic resonance angiography, and finally the digital subtraction angiography, first independently and then in consensus. The status of aneurysm occlusion was assessed according to the Raymond scale, which indicates the level of recanalization according to degrees: Class 1: excluded aneurysm; Class 2: persistence of a residual neck; Class 3: persistence of a residual aneurysm. The agreement among the analyses was assessed by applying the Kappa statistic. RESULTS: Inter-observer agreement was excellent for both methods (K = 0.93; 95 % CI: 0.84-1. Inter-technical agreement was almost perfect between time-of-flight-magnetic resonance angiography and digital subtraction angiography (K = 0.98; 95 % CI: 0.93-1 and between time-of-flight-magnetic resonance angiography and contrast-enhanced-magnetic resonance angiography (K = 0.98; 95% CI: 0.93-1. Disagreement occurred in only one case (2.3%, which was classified as Class I by time-of-flight-magnetic resonance angiography and Class II by digital subtraction angiography. The agreement between

  15. An investigation of cerebral magnetic resonance angiography, 4

    International Nuclear Information System (INIS)

    Takeda, Sadanori; Sadamoto, Kazuhiko; Ohue, Shiro; Todo, Hirooki; Sakaki, Saburo.

    1991-01-01

    We have been studying MR angiography using the 0.5 tesla system. Recently we developed three-dimensional MR angiography on the 0.5 tesla system using the gradient-echo technique. The purpose of this study is to evaluate the clinical ability of this newly developed 3-D MR angiography to detect intracranial vascular diseases in comparison with SE or 2-D MR angiography. Twenty-eight patients (15 cerebral aneurysms, 8 arteriovenous malformations, and 5 others) were examined. Three-dimensional MR angiography was performed with TRs of from 60 to 90 msec, TEs of from 16 to 22 msec, flip angls of from 15 to 45 degrees, and a 256x256x16 or 32 matrix. The imaging volumes ranged in thickness from 48 to 64 mm. In our study, a subtraction technique composed of rephased and dephased sequences was applied. As the result of utilizing 0.5 tesla 3-D MR angiography with optimal parameters, good visualization of main cerebral arteries such as second-order branches was obtained. Cerebral aneurysms, AVMs, and arterial occlusions were also well demonstrated, but some of the giant aneurysms were displayed insufficiently for the various flows to be determined. We concluded that 3-D MR angiography on the 0.5 tesla system has the ability to detect intracranial vascular lesions and should be the method for the screening and follow-up of intracranial vascular diseases. (author)

  16. Speciation analysis of radionuclides

    International Nuclear Information System (INIS)

    Salbu, B.

    2010-01-01

    Full text: Naturally occurring and artificially produced radionuclides in the environment can be present in different physico-chemical forms (i. e. radionuclide species) varying in size (nominal molecular mass), charge properties and valence, oxidation state, structure and morphology, density, complexing ability etc. Low molecular mass (LMM) species are believed to be mobile and potentially bioavailable, while high molecular mass (HMM) species such as colloids, polymers, pseudocolloids and particles are considered inert. Due to time dependent transformation processes such as mobilization of radionuclide species from solid phases or interactions of mobile and reactive radionuclide species with components in soils and sediments, however, the original distribution of radionuclides deposited in ecosystems will change over time and influence the ecosystem behaviour. To assess the environmental impact from radionuclide contamination, information on radionuclide species deposited, interactions within affected ecosystems and the time-dependent distribution of radionuclide species influencing mobility and biological uptake is essential. The development of speciation techniques to characterize radionuclide species in waters, soils and sediments should therefore be essential for improving the prediction power of impact and risk assessment models. The present paper reviews fractionation techniques which should be utilised for radionuclide speciation purposes. (author)

  17. The role equilibrium leach testing in understanding the behaviour of nuclear wastes under disposal conditions

    International Nuclear Information System (INIS)

    Biddle, P.; Rees, J.H.

    1988-01-01

    Results from the equilibrium leach testing of a range of intermediate level nuclear wastes have been modelled successfully using sorption and solubility data obtained in experiments with individual radionuclides. The wastes involved included fuel cladding (after removal of irradiated fuel for reprocessing), combustible plutonium-contaminated materials and ferric/aluminium hydroxide flocs. The test has an important role in validating nearfield models, and helps to build confidence in disposal assessments. (orig.)

  18. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot ... I’d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA ...

  19. New method of digital angiography

    International Nuclear Information System (INIS)

    Hashiya, Junichi; Korenaga, Takeo; Sakurai, Kenji; Sakai, Fumikazu; Kato, Hisatoyo; Takano, Masao.

    1982-01-01

    New experience of digital angiography using Fuji Intelligent Diagnostic X-ray System was reported. The system utilizes newly developed high sensitivity imaging plate in conjunction with computerized image processor instead of image intensifier-TV series, thus drastically improving image quality. Initial clinical trial was made in 46 cases including intravenous digital subtraction angiography and transcatheter digital arteriography. The advantages of this method were summerized as: 1. better resolution, 2. wider field size, 3. more sophisticated image manipulation program. (author)

  20. The role of equilibrium leach testing in understanding the behaviour of nuclear wastes under disposal conditions

    International Nuclear Information System (INIS)

    Biddle, P.; Rees, J.H.

    1988-01-01

    Results from the equilibrium leach testing of a range of intermediate level nuclear wastes have been modelled using sorption and solubility data obtained in experiments with individual radionuclides. The wastes involved were AGR hulls, Magnox cladding wastes, combustible plutonium-contaminated materials and ferric/aluminium hydroxide flocs. The test has an important role in validating near-field models, and helps to build confidence in disposal assessments. (author)

  1. Magnetic resonance angiography (MRA) of the circle of Willis: a prospective comparison with conventional angiography in 54 subjects

    International Nuclear Information System (INIS)

    Patrux, B.; Laissy, J.P.; Jouini, S.; Kawiecki, W.; Coty, P.; Thiebot, J.

    1994-01-01

    We prospectively correlated the findings of magnetic resonance angiography (MRA) with those of transfemoral four-vessel angiography in 54 patients to investigate the direction of flow within the circle of Willis. Our primary goal was to assess the direction of flow using the size of the vessel and signal intensity, without saturation techniques. Analysis of the circle of Willis, especially the communicating arteries, was performed double-blind by two groups of two radiologists. Three types of arteries were identified: high flow or cross-cerebral circulation, patent and nonvisualised arteries. Cerebral angiography was the standard for comparison between the two methods. MRA did not reveal any arteries invisible on angiography, thus providing a specificity of 100%. The sensitivity of MRA was 89.2% for the anterior and 81.3% for the posterior communicating arteries, and 100% for the anterior, middle and posterior cerebral arteries. MRA was shown to be a useful technique for the assessment of patency of the circle of Willis. (orig.)

  2. Magnetic resonance angiography (MRA) of the circle of Willis: a prospective comparison with conventional angiography in 54 subjects

    Energy Technology Data Exchange (ETDEWEB)

    Patrux, B. (Neuroradiology, CHU Charles Nicolle, Rouen (France)); Laissy, J.P. (Neuroradiology, CHU Charles Nicolle, Rouen (France) Dept. of Radiology, CHU Bichat, Paris (France)); Jouini, S. (Neuroradiology, CHU Charles Nicolle, Rouen (France)); Kawiecki, W. (Siemens Medical Systems, Saint-Denis (France)); Coty, P. (Neuroradiology, CHU Charles Nicolle, Rouen (France)); Thiebot, J. (Neuroradiology, CHU Charles Nicolle, Rouen (France))

    1994-04-01

    We prospectively correlated the findings of magnetic resonance angiography (MRA) with those of transfemoral four-vessel angiography in 54 patients to investigate the direction of flow within the circle of Willis. Our primary goal was to assess the direction of flow using the size of the vessel and signal intensity, without saturation techniques. Analysis of the circle of Willis, especially the communicating arteries, was performed double-blind by two groups of two radiologists. Three types of arteries were identified: high flow or cross-cerebral circulation, patent and nonvisualised arteries. Cerebral angiography was the standard for comparison between the two methods. MRA did not reveal any arteries invisible on angiography, thus providing a specificity of 100%. The sensitivity of MRA was 89.2% for the anterior and 81.3% for the posterior communicating arteries, and 100% for the anterior, middle and posterior cerebral arteries. MRA was shown to be a useful technique for the assessment of patency of the circle of Willis. (orig.)

  3. Quantitative radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Scholz, P.M.; Rerych, S.K.; Moran, J.F.; Newman, G.E.; Douglas, J.M.; Sabiston, D.C. Jr.; Jones, R.H.

    1980-01-01

    This study introduces a new method for calculating actual left ventricular volumes and cardiac output from data recorded during a single transit of a radionuclide bolus through the heart, and describes in detail current radionuclide angiocardiography methodology. A group of 64 healthy adults with a wide age range were studied to define the normal range of hemodynamic parameters determined by the technique. Radionuclide angiocardiograms were performed in patients undergoing cardiac catherization to validate the measurements. In 33 patients studied by both techniques on the same day, a close correlation was documented for measurement of ejection fraction and end-diastolic volume. To validate the method of volumetric cardiac output calcuation, 33 simultaneous radionuclide and indocyanine green dye determinations of cardiac output were performed in 18 normal young adults. These independent comparisons of radionuclide measurements with two separate methods document that initial transit radionuclide angiocardiography accurately assesses left ventricular function

  4. Intracrystalline diffusion in clinoptilolite: Implications for radionuclide isolation

    International Nuclear Information System (INIS)

    Roberts, S.K.; Viani, B.E.; Phinney, D.

    1995-01-01

    Experiments have been performed to measure the rate of exchange diffusion in the zeolite clinoptilolite (CL) for elements important to radionuclide isolation at Yucca Mountain, NV. Clinoptilolite is one of the major sorptive minerals in the tuffs at Yucca Mountain, and occurs both as a major component in zeolitized units (Calico Hills), and in fractures in non-zeolitized tuffs (Topopah Spring). Field evidence and numerical modeling suggests that the movement of fluids through the tuff rocks adjacent to the potential repository may occur via episodic flow through fractures. Under conditions of rapid fracture flow the effective sorptive capacity of fracture-lining clinoptilolite may be controlled by exchange diffusion rather than exchange equilibrium

  5. Comments on equilibrium, transient equilibrium, and secular equilibrium in serial radioactive decay

    International Nuclear Information System (INIS)

    Prince, J.R.

    1979-01-01

    Equations describing serial radioactive decay are reviewed along with published descriptions or transient and secular equilibrium. It is shown that terms describing equilibrium are not used in the same way by various authors. Specific definitions are proposed; they suggest that secular equilibrium is a subset of transient equilibrium

  6. CT Angiography in the Diagnosis of Brain Death

    International Nuclear Information System (INIS)

    Sawicki, Marcin; Bohatyrewicz, Romuald; Walecka, Anna; Sołek-Pastuszka, Joanna; Rowiński, Olgierd; Walecki, Jerzy

    2014-01-01

    Summary Brain death is defined as the irreversible cessation of functioning of the entire brain, including the brainstem. Brain death is principally established using clinical criteria including coma, absence of brainstem reflexes and loss of central drive to breathe assessed with apnea test. In situations in which clinical testing cannot be performed or when uncertainty exists about the reliability of its parts due to confounding conditions ancillary tests (i.a. imaging studies) may be useful. The objective of ancillary tests in the diagnosis of brain death is to demonstrate the absence of cerebral electrical activity (EEG and evoked potentials) or cerebral circulatory arrest. In clinical practice catheter cerebral angiography, perfusion scintigraphy, transcranial Doppler sonography, CT angiography and MR angiography are used. Other methods, like perfusion CT, xenon CT, MR spectroscopy, diffusion weighted MRI and functional MRI are being studied as potentially useful in the diagnosis of brain death. CT angiography has recently attracted attention as a promising alternative to catheter angiography – a reference test in the diagnosis of brain death. Since 1998 several major studies were published and national guidelines were introduced in several countries (e.g. in France, Austria, Switzerland, the Netherlands and Canada). This paper reviews technique, characteristic findings and criteria for the diagnosis of cerebral circulatory arrest in CT angiography

  7. Treatment of arteriovenous malformations with stereotactic radiosurgery employing both magnetic resonance angiography and standard angiography as a database

    International Nuclear Information System (INIS)

    Petereit, D.; Mehta, M.; Turski, P.; Levin, A.; Strother, C.; Mistretta, C.; Mackie, R.; Gehring, M.; Kubsad, S.; Kinsella, T.

    1993-01-01

    Twenty-one arteriovenous malformations were prospectively evaluated using magnetic resonance angiography, compare it to stereotactic angiography, employ magnetic resonance angiography in follow-up, and semiquanitfy flow. A correlative evaluation between flow and response to stereotactic radiosurgery was carried out. Phase contrast angiograms were obtained at flow velocities of 400, 200, 100, 60 and 20 cm/sec. The fractionated velocities provided images that selectively demonstrated the arterial and venous components of the arteriovenous malformations. Qualitative assessment of the velocity within the arteriovenous malformations and the presence of fistulae were also determined by multiple velocity images. In addition, 3-dimensional time-of-flight magnetic resonance angiograms were obtained to define the exact size and shape of the nidus. This technique also permitted evaluation of the nidus and feeding arteries for the the presence of low flow aneurysms. Correlation between the two imaging modalities was carried out by subjective and semiquantitative estimation of flow velocity and estimation of nidus size. The following velocity parameters were employed: fast, intermediate, slow, and none. Early analysis suggests that slower flowing arteriovenous malformations may obliterate faster after stereotactic radiosurgery an flow parameters should be employed to predict response. In conclusion, magnetic resonance angiography permits semiquantitative flow velocity assessment and may therefore be superior to stereotactic angiography. An additional advantage of magnetic resonance angiography is the generation of serial transverse images which can replace the conventional CT scan employed for stereotactic radiosurgery treatment planning. A single diagnostic test may therefore be used for diagnosis, radiosurgical treatment planning, follow-up, and treatment selection by identifying patients likely to respond early to radiosurgical management

  8. Geochemical studies of sorption and transport of radionuclides in rock media

    International Nuclear Information System (INIS)

    Coles, D.G.; Weed, H.C.; Tewhey, J.D.

    1980-01-01

    Four studies, which supported the goals of the WISAP Program at Battelle PNL, were undertaken by the Lawrence Livermore Laboratory during FY 1979. These were: (1) Batch K/sub d/ experiments, (2) Dynamic sorption experiments on rock cores, (3) Feasibility study for an in situ tracer test at the Climax Stock, NTS, and (4) Geochemical equilibrium code development. Only the equilibrium code development was not funded by the WISAP during FY 1979. The emphasis for the batch K/sub d/ studies was on various (15) sandstones in brine using 75 Se, 85 Sr, 125 Sb, 137 Cs, 141 Ce, and 237 Pu tracers. These sandstone samples were well-characterized for their physical and mineralogical nature. Complex K/sub d/ behavior was observed for the radionuclides studied but 85 Sr showed K/sub d/ values near zero for all samples. Both 141 Ce and 239 Pu K/sub d/ values ranged from 20 to upper limits of greater than or equal to 17,000. Dynamic sorption studies were done on NTS tuff and St. Peter sandstone core using 3 H, 85 Sr, and /sup 95m/Tc. These radionuclides were injected as a short pulse into the rock-equilibrated water that was flowing through the core. Tracer-free water was then continually flowed through the core until elution curves for the mobile radionuclides were established. Tritium and /sup 95m/Tc both traveled through the cores at the same rate, indicating no sorption for the mobile fraction of /sup 95m/Tc ( 95 TcO 4 - ). Strontium-85 did not exit the tuff cores but did exit the sandstone core although the elution curves showed definite retardation relative to the movement of 3 H and /sup 95m/Tc. Post-elution sectioning of the cores indicated that a fraction of the /sup 95m/Tc remained in the cores and was evenly distributed through the tuff cores. Strontium-85 showed a generally decreasing distribution from the inlet side to the outlet side of the tuff cores

  9. Application of radionuclide techniques in evaluation of dilated cardiomyopathy and ischemic cardiomyopathy

    International Nuclear Information System (INIS)

    Tian Yueqin; Liu Xiujie; Shi Rongfang

    2000-01-01

    Objective: To assess the clinical significance of radionuclide techniques in differentiating dilated cardiomyopathy (DCM) from ischemic cardiomyopathy (CAD-CM). Methods: 28 patients (pts) with DCM and 55 pts with CAD-CM were studied. All pts underwent 99 Tc m -MIBI myocardial perfusion SPECT and 18 F-FDG myocardial metabolic PET. 73 pts had 99 Tc m -RBC radionuclide ventriculography and 68 pts had coronary angiography. Results: 23 pts (82%) with DCM showed perfusion abnormalities with mild and not segmental distribution. 52 pts (95%) with CAD-CM showed perfusion abnormalities that distributed along the coronary vessel territories. Perfusion defects were found in 4 pts (14%) with DCM and 45 pts (82%) with CAD-CM (P<0.01). The average perfusion score was 4.5 +- 2.6 in DCM and 9.5 +- 2.9 in CAD-CM, the area of perfusion diminished uptake was significantly smaller in DCM than in CAD-CM (P < 0.001). 2 pts with DCM and 18 pts with CAD-CM had metabolic defect. The patterns of perfusion/metabolic imaging showed mismatch in most pts with CAD-CM but match in pts with DCM. The LVEF in pts with DCM and CAD-CM was decreased but no significant difference between DCM and CAD-CM was observed. The RVEF in pts with DCM was significantly lower than that in pts with CAD-CM (32.4% +- 13.9% vs 40.9% +- 15.4%, P < 0.05). Conclusions: The radionuclide techniques showed to be helpful for distinguishing DCM from CAD-CM. The discriminate analysis revealed that segmental perfusion abnormality and RVEF were the most important factors for differentiation of DCM from CAD-CM

  10. Clinical experience of magnetic resonance angiography in hand surgery

    International Nuclear Information System (INIS)

    Kawabata, Hidehiko; Yasui, Natsuo; Kitano, Motohiro; Sai, Eikoh

    1996-01-01

    Magnetic resonance angiography was performed in fourteen patients with congenital hand abnormalities. A two-dimentional time-of-flight imaging clearly demonstrated presence or absence of the radial, ulnar, and anterior interosseous arteires at forearm. However, smaller arteries such as digital arteries were depressed sometimes. This fact makes clinical application of the method somewhat limited. At present. appropriate applications in orthopaedic fields are evaluation of run-off of the major vessels after trauma or atherosclerotic diseases, venous vascular problems such as thrombophlebitis and aneurysm, and preoperative and post operative evaluation in microsurgery. If more detailed information is required, for example, in differential diagnosis of tumors conventional angiography or digital subtraction angiography is recommended. Because magnetic resonance angiography is non-invasive and does not need anesthesia, it is suitable especially for children. No requirement of contrast medium makes it easy to apply angiography to high risk patients and allergic patients to iodine. Technical advancement in near future will rise up magnetic resonance angiography to a standard evaluation method for vascular problems in orthopaedic fields very soon. (author)

  11. Digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Ludwig, J.W.; Eikelboom, B.C.; Van Schaik, C.C.; Taams, A.J.; Teeuwen, C.

    1985-01-01

    Besides the non-invasive techniques, angiography remains essential. The disadvantages of angiography are the complexity of the procedure and the possibility of complications. Digital subtraction angiography (DSA) is a considerable improvement in the examination of vessels. In DSA, subtraction combined with enhancement of the signals allows the use of intravenous injection to obtain good images of the arteries. However, when the contrast material is supplied intravenously, a rather large amount of contrast material is necessary to obtain images of good quality. Quantities of 30-40 cc of contrast material are required. The advantage of the intravenous injection of contrast material rather than the use of a catheter to deliver the contrast material in loco is that it is almost non-invasive thus circumventing the complications caused by catheter manipulation in the arterial system. This makes it possible to apply this method on an out-patient basis. DSA can also be applied with intra-arterial selective injection of the contrast material. In this case, the strong enhancement with DSA allows the use of a small quantity of contrast material while still obtaining images of the vessels with good contrast definition

  12. Surfactant-impregnated activated carbon for enhanced adsorptive removal of Ce(IV) radionuclides from aqueous solutions

    International Nuclear Information System (INIS)

    Mahmoud, Mamdoh R.; Sharaf El-deen, Gehan E.; Soliman, Mohamed A.

    2014-01-01

    Highlights: • Activated carbon (AC) was impregnated in this work with CTAB and NaLS surfactants. • The materials were evaluated as a sorbent for adsorption of Ce(IV) radionuclides. • Adsorption capacity of AC–NaLS for Ce(IV) is two-times the capacity of AC. • The kinetic and equilibrium data are fitted to pseudo-second-order and D–R models. • The results suggest the applicability of surface modified AC for waste treatment. - Abstract: The surfactants cetyltrimethylammonium bromide (CTAB) and sodium lauryl sulfate (NaLS) were utilized for modifying the activated carbon’s surface. The materials were characterized using BET–N 2 , scanning electron microscope, and Fourier transform infrared (FT-IR) spectroscopy. Adsorption of Ce(IV) radionuclides from aqueous solutions by activated carbon (AC) and surfactant-impregnated AC was studied. The obtained data showed that adsorption of Ce(IV) is strongly dependent on the solution pH and AC–NaLS exhibits the widest pH-range of maximum removal. The experimental adsorption capacity of AC–NaLS (0.069 mmol/g) for Ce(IV) is found to be nearly twice greater than that of AC (0.036 mmol/g). The adsorption kinetics of Ce(IV) onto AC and AC–NaLS were analyzed by linear and non-linear fittings to the pseudo-first-order, pseudo-second-order and Elovich kinetic models. Of these models, the pseudo-second-order is the best kinetic expression for describing the experimental data. The diffusion studies indicated that adsorption of Ce(IV) radionuclides on AC and AC–NaLS is controlled by film diffusion. Linear and non-linear fittings of the adsorption equilibrium data for Ce(IV) onto AC and AC–NaLS revealed that the Dubinin–Radushkevich (D–R) isotherm model fits the experimental data better than Freundlich and Langmuir models. The values of adsorption free energy, E, calculated from both linear and non-linear methods suggested that Ce(IV) radionuclides are physically adsorbed onto AC and AC–NaLS

  13. Engineering MerR for Sequestration and MerA for Reduction of Toxic Metals and Radionuclides

    International Nuclear Information System (INIS)

    Summers, Anne O.

    2008-01-01

    The objectives of this project were (1) to alter a metalloregulatory protein (MerR) so that it would bind other toxic metals or radionuclides with similar affinity so that the engineered protein itself and/or bacteria expressing it could be deployed in the environment to specifically sequester such metals and (2) to alter the mercuric reductase, MerA, to reduce radionuclides and render them less mobile. Both projects had a basic science component. In the first case, such information about MerR illuminates how proteins discriminate very similar metals/elements. In the second case, information about MerA reveals the criteria for transmission of reducing equivalents from NADPH to redox-active metals. The work involved genetic engineering of all or parts of both proteins and examination of their resultant properties both in vivo and in vitro, the latter with biochemical and biophysical tools including equilibrium and non-equilibrium dialysis, XAFS, NMR, x-ray crystallography, and titration calorimetry. We defined the basis for metal specificity in MerR, devised a bacterial strain that sequesters Hg while growing, characterized gold reduction by MerA and the role of the metallochaperone domain of MerA, and determined the 3-D structure of MerB, the organomercurial lyase.

  14. Uterine artery embolization angiography and fertility related aspects

    Directory of Open Access Journals (Sweden)

    Irina A. Horhoianu

    2016-05-01

    Full Text Available Purpose. Uterine artery embolization is a minimally invasive technique. It applies the principle of targeted anatomical structure devascularisation with utility in fibroid conservative therapy, including for future fertility preserving status. The objective of our paper represents a description and evaluation of angiography utility as a predictive method for fertility maintenance. Material and Methods. The angiography and ultrasound aspects obtained from a prospective study in which selected patients have undergone uterine artery embolization for fertility preservation are detailed. Results. The following angiography aspects have been detected: left- right shunt and utero-ovarian collaterals; these have been compared with the ultrasound aspects related to the fibroid evolution form a volumetric and Doppler ultrasound point of view. The angiographical description predicts the impact on post embolization fibroid evolution and upon fertility. An analysis is made in order to assess the way in which angiography can contribute to fertility alteration. Conclusions. The angiography aspects during embolization and the following ultrasound aspects can represent predictive factors as to fertility evolution after uterine artery embolization.

  15. Effect of including decay chains on predictions of equilibrium-type terrestrial food chain models

    International Nuclear Information System (INIS)

    Kirchner, G.

    1990-01-01

    Equilibrium-type food chain models are commonly used for assessing the radiological impact to man from environmental releases of radionuclides. Usually these do not take into account build-up of radioactive decay products during environmental transport. This may be a potential source of underprediction. For estimating consequences of this simplification, the equations of an internationally recognised terrestrial food chain model have been extended to include decay chains of variable length. Example calculations show that for releases from light water reactors as expected both during routine operation and in the case of severe accidents, the build-up of decay products during environmental transport is generally of minor importance. However, a considerable number of radionuclides of potential radiological significance have been identified which show marked contributions of decay products to calculated contamination of human food and resulting radiation dose rates. (author)

  16. Kinetics and reversibility of radionuclide sorption reactions with rocks. Progress report for fiscal year 1979

    International Nuclear Information System (INIS)

    Barney, G.S.; Brown, G.E.

    1979-01-01

    Sorption-desorption reactions of cesium, strontium, neptunium, americium, and plutonium on basalt, granite, and argillite were observed for 218 days. Equilibrium in batch experiments was not reached for most radionuclides even after this long time. Reactions of the crushed rock with ground waters (dissolution, hydrolysis, precipitation, etc.) also did not reach equilibrium after 150 days. The dissolution of basalt is accompanied by the formation of colloidal particles which contain Si, Fe, Ca, and Al. These colloids sorb Cs, Sr, Am, and Pu during equilibration. Some of the colloids pass through 0.3-μm flters, are not retained even on 0.01-μm filters and, therefore, cause calculated K/sub d/ values to be too low. Samples of crushed basalt, granite, and argillite were artificially weathered by continuous leaching with distilled water for 6 months both in air and in an oxygen-free stream of nitrogen gas. The weathered rock was then characterized for surface area, surface structure, cation exchange capacity, and composition of weathered surface on the rock. Comparisons were made of radionuclide sorption (after 14 days) on fresh rock, rock weathered in air, and rock weathered in N 2 . Sorption on rocks weathered in N 2 generally is less than on rock weathered in air. This is possibly due to the lack of an Fe(OH) 3 coating on the rock weathered in N 2 . The Fe(OH) 3 is known to scavenge cations and silica from solution. Sorption of Cs, Si, Am, and Pu is strongly affected by weathering basalt and argillite. However, the cation exchange capacity is changed very little, suggesting that ion exchange plays a minor role in sorption of these radionuclides

  17. A sensitive and quantitative biosensing method for the determination of {gamma}-ray emitting radionuclides in surface water

    Energy Technology Data Exchange (ETDEWEB)

    Wolterbeek, H.Th.; Meer, A.J.G.M. van der [Technische Univ. Delft (Netherlands). Interfacultair Reactor Inst.

    1996-11-01

    A quantitative and sensitive biosensing method has been developed for the determination of {gamma}-ray emitting radionuclides in surface water. The method is based on the concept that at equilibrium the specific radioactivity in the biosensor is equal to the specific radioactivity in water. The method consists of the measurement of both the radionuclide and the element in the biosensor and the determination of the element level in water. This three-way analysis eliminates problems such as unpredictable biosensor behaviour, effects of water elemental composition or further abiotic parameters: what remains is the generally high enrichment (bioaccumulation factor BCF) of elements and radionuclides in the biosensor material. Measurements were performed with floating water plants (Azolla filiculoides Lamk., Spirodela polyrhiza/Lemna sp.) and the fully submerged water plant Ceratophyllum demersum L., which were sampled from ditch water. Concentrations of elements and radionuclides were determined in both water and biosensor plants, using Neutron Activation Analysis (NAA), ICP-MS, and {gamma}-ray spectrometry, respectively. For the latter, both 1 litre samples (Marinelli-geometry) and 1 cm{sup 3} samples (well-type detectors) were applied in measurements. (author).

  18. Selective angiography in fifty patients with primary hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Shou-Zhong, Wang; Xing-Rong, Chen; Gong-Xian, Wang

    1983-06-01

    Selective angiography is of great importance in the diagnosis of primary hepatocellular carcinoma. It offers information on the findings, multicentricity, localisation, extension, and type of growth. This paper discusses angiography from the methodical point of view, the findings to be obtained, the types of hepatocellular carcinoma, and the diagnostic efficiency of selective angiography in the evaluation of this type of tumour.

  19. Detection of exercise induced ischemia in the asymptomatic recent post myocardial infarction patient: comparison of stress electrocardiography and radionuclide angiography

    International Nuclear Information System (INIS)

    Jengo, J.A.; Brizendine, M.; Dykstra, L.; Sweet, J.; Bruno, M.; Garcia, A.

    1982-01-01

    The purpose of this study was to compare the techniques of low level stress electrocardiography and radionuclide angiographic wall motion analysis for the detection of new areas of myocardial ischemia in the asymptomatic recent post-myocardial infarction patient. The protocol consisted of obtaining a resting, RAO upright first pass radionuclide angiocardiogram using 15 mCi of 99m technetium-DTPA. The study suggests that assessment of segmental wall motion during low level stress can detect areas of myocardium at high risk either intermixed with or in addition to recently infarcted areas in the asymptomatic post-infarction patient, which are not detected by ECG. This high risk subset of patients can then be observed or treated in a more vigorous manner. This technique allows for not only the identification of additional areas of myocardium at jeopardy but also provides information regarding the severity of ischemic dysfunction, an important prognostic and therapeutic factor

  20. Facts and features of radionuclide migration in Boom Clay

    International Nuclear Information System (INIS)

    De Regge, P.; Henrion, P.; Monsecour, M.; Put, M.

    1988-01-01

    The evolution which took place during ten years of research on the behaviour of radionuclides in Boom Clay is described. Initially, the Boom Clay was regarded as a chemically inert exchanger and the radiochemical research aimed at determining the distribution of cations between the clay and some liquid phases. The observation that Boom Clay deteriorates in contact with air and loses important intrinsic properties formed a major breakthrough in the research and led to a careful examination of the real in-situ conditions. Efforts devoted to the understanding of the chemical factors pertaining to the pH, the redox potential, the extent of the buffering capacity of FeS 2 and CaCO 3 in equilibrium with the interstitial aqueous phase are reviewed. Also emerging from the overall picture was the role of the organic material present in the Boom Clay. In contrast to the water percolating fractured formations which may not be in equilibrium with the rock, the interstitial aqueous phase is completely in equilibrium with Boom Clay mainly because of its low permeability and the large excesses of buffering components. As the retention mechanisms are better understood, a more coherent picture is obtained from distribution and diffusion experiments and the effects of consolidation are being investigated in detail. 23 refs.; 4 figs.; 3 tabs

  1. Radionuclide fixation mechanisms in rocks

    International Nuclear Information System (INIS)

    Nakashima, S.

    1991-01-01

    In the safety evaluation of the radioactive waste disposal in geological environment, the mass balance equation for radionuclide migration is given. The sorption of radionuclides by geological formations is conventionally represented by the retardation of the radionuclides as compared with water movement. In order to quantify the sorption of radionuclides by rocks and sediments, the distribution ratio is used. In order to study quantitatively the long term behavior of waste radionuclides in geological environment, besides the distribution ratio concept in short term, slower radionuclide retention reaction involving mineral transformation should be considered. The development of microspectroscopic method for long term reaction path modeling, the behavior of iron during granite and water interaction, the reduction precipitation of radionuclides, radionuclide migration pathways, and the representative scheme of radionuclide migration and fixation in rocks are discussed. (K.I.)

  2. Decay profiles of {beta} and {gamma} for a radionuclide inventory in equilibrium cycle of a BWR type reactor; Perfiles de decaimiento de radiacion {beta} y {gamma} para un inventario de radionuclidos en ciclo de equilibrio de un reactor tipo BWR

    Energy Technology Data Exchange (ETDEWEB)

    Salaices, M.; Sandoval, S.; Ovando, R. [Instituto de Investigaciones Electricas. Gerencia de Energia Nuclear, Av. Reforma 113 Col. Palmira. 62490 Cuernavaca, Morelos (Mexico)]. e-mail: sal@iie.org.mx

    2007-07-01

    Presently work the {beta} and {gamma} radiation decay profiles for a radionuclides inventory in equilibrium cycle of a BWR type reactor is presented. The profiles are presented in terms of decay in the activity of the total inventory as well as of the chemical groups that conform the inventory. In the obtaining of the radionuclides inventory in equilibrium cycle the ORIGEN2 code, version 1 was used, which simulates fuel burnup cycles and it calculates the evolution of the isotopic composition as a result of the burnt one, irradiation and decay of the nuclear fuel. It can be observed starting from the results that the decrease in the activity for the initial inventory and the different chemical groups that conform it is approximately proportional to the base 10 logarithm of the time for the first 24 hours of having concluded the burnt one. It can also be observed that the chemical groups that contribute in more proportion to the total activity of the inventory are the lanthanides-actinides and the transition metals, with 39% and 28%, respectively. The groups of alkaline earth metals, halogens, metalloids, noble gases and alkaline metals, contribute with percentages that go from the 8 to 5%. The groups that less they contribute to the total activity of the inventory they are the non metals and semi-metals with smaller proportions that 1%. The chemical groups that more contribute to the energy of {beta} and {gamma} radiation its are the transition metals and the lanthanides-actinides with a change in the order of importance at the end of the 24 hours period. The case of the halogens is of relevance for the case of the {gamma} radiation energy due that occupying the very near third site to the dimensions of the two previous groups. Additionally, the decay in the activity for the total inventory and the groups that conform it can be simulated by means of order 6 polynomials or smaller than describe its behavior appropriately. The results presented in this work, coupled

  3. Determination of differences in the left ventricular ejection fraction (LVEF) by radionuclides and echocardiography pre and post treatment with anthracycline in pediatric patients with oncology diagnostic of the La Raza Medical Center

    International Nuclear Information System (INIS)

    Veras R, H.

    2003-01-01

    The objective of this work was to correlate the left ventricular ejection fraction determine by radionuclide angiocardiography and echocardiography in pediatric patients under anthracycline treatment. Material and methods: 41 patients were studied with range age from 3 to 14 years, with oncology diagnostic that were treated with anthracycline. Radionuclide angiocardiography and echocardiography were performed before an after anthracycline administration to determine the changes in the Ieft ventricular ejection fraction. Results: Anthracycline treatment caused no changes in the electrocardiography, echocardiogram and radionuclide angiocardiography. Conclusions: In our study anthracycline treatment caused no changes in the electrocardiography, echocardiography and both radionuclide angiocardiography techniques, first-pass and equilibrium. A high correlation was obtaining when left ventricular ejection fraction is compared between radionuclide angiocardiography and echocardiogram. (Author)

  4. Digital angiography and surgery in the same room

    International Nuclear Information System (INIS)

    Goldman, M.L.; Hack, S.N.; Sarrafizadeh, M.S.; Marar, H.G.; Behar, D.J.; Chigurupati, R.C.; Klein, S.I.; Widlus, D.M.; Fortune, J.B.

    1986-01-01

    Albany Medical Center and private industries (XRE and United X-ray corporations) have collaborated to develop a room within the operating suite that allows high-speed and high-resolution digital angiography and surgery to be performed simultaneously. Patients who have sustained massive trauma can be transferred directly from the ambulance to this new facility. While the patient is undergoing exploratory laparotomy, other vital areas of the body can be evaluated by angiography. This combined approach of surgery and angiography has also led to improved management of patients with massive or occult intestinal hemorrhage and patients with peripheral vascular disease. Other patients undergoing difficult emergency or elective surgery, as in the biliary tract, can now have available the benefits of an operating room facility that also allows high-resolution fluoroscopy and complete angiography to be undertaken

  5. Distribution of radionuclides and elements in Cubatao River sediments

    International Nuclear Information System (INIS)

    Silva, P.S.C.; Mazzilli, B.P.; Favaro, D.I.T.

    2006-01-01

    Cubatao River is located in Santos Basin, Sao Paulo State, Brazil. This region is characterized by the occurrence of estuaries and mangrove. Due to its location, near the coastal line, it is also an important industrial area, where phosphate fertilizer plants, petrol refineries, and chemical and steel industries are present. Such human activities contribute to the enhancement of elemental composition in sediments and, in some cases, also increase the radionuclide concentrations, the so called Technologically Enhanced Natural Occurring Radioactive Materials (TENORM). The contamination of land and sediments by TENORM is of major concern. The activity concentration of U and Th series radionuclides was determined in five sediment samples from Cubatao River. The activity concentration ratio was also determined. Equilibrium was observed for the ratio 234 U/ 238 U. The activity ratios of Th/ 238 U, 228 Ra/ 226 Ra and 210 Pb/ 226 Ra were higher than the unity. In the first two cases, the observed values are due to the higher activity of Th in the sediment and in the last case are probably due to the atmospheric deposition of 210 Pb. (author)

  6. Quantitation of aortic and mitral regurgitation in the pediatric population: evaluation by radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Hurwitz, R.A.; Treves, S.; Freed, M.; Girod, D.A.; Caldwell, R.L.

    1983-01-01

    The ability to quantitate aortic (AR) or mitral regurgitation (MR), or both, by radionuclide angiocardiography was evaluated in children and young adults at rest and during isometric exercise. Regurgitation was estimated by determining the ratio of left ventricular stroke volume to right ventricular stroke volume obtained during equilibrium ventriculography. The radionuclide measurement was compared with results of cineangiography, with good correlation between both studies in 47 of 48 patients. Radionuclide stroke volume ratio was used to classify severity: the group with equivocal regurgitation differed from the group with mild regurgitation (p less than 0.02); patients with mild regurgitation differed from those with moderate regurgitation (p less than 0.001); and those with moderate regurgitation differed from those with severe regurgitation (p less than 0.01). The stroke volume ratio was responsive to isometric exercise, remaining constant or increasing in 16 of 18 patients. After surgery to correct regurgitation, the stroke volume ratio significantly decreased from preoperative measurements in all 7 patients evaluated. Results from the present study demonstrate that a stroke volume ratio greater than 2.0 is compatible with moderately severe regurgitation and that a ratio greater than 3.0 suggests the presence of severe regurgitation. Thus, radionuclide angiocardiography should be useful for noninvasive quantitation of AR or MR, or both, helping define the course of young patients with left-side valvular regurgitation

  7. Correlation of angiography and MR imaging in cerebral vasculitis

    International Nuclear Information System (INIS)

    Cloft, H.J.; Phillips, C.D.; Dix, J.E.; McNulty, B.C.; Kallmes, D.F.; Zagardo, M.T.

    1999-01-01

    Purpose: MR imaging and cerebral angiography were correlated in patients with primary angiitis of the central nervous system (PACNS) to assess the relative roles of these imaging modalities in the diagnosis. Material and Methods: In 9 patients, MR imaging and angiography were compared with regard to the relative involvement of each major vascular territory. Vascular territories assessed were the anterior, middle, and posterior cerebral arteries, and the posterior fossa. Results: All patients had angiographic findings consistent with vasculitis in multiple vascular territories. MR findings ranged from normal to diffusely abnormal. One patient had a completely normal MR investigation. Of 50 territories affected by vasculitis on angiography, 17 (34%) were normal on MR. Conclusion: Relative to cerebral angiography, MR imaging is a poor indicator of the presence or absence of PACNS. Angiography is indicated when clinical suspicion of PACNS is strong, regardless of the findings on MR. (orig.)

  8. Marine biogeochemistry of radionuclides

    International Nuclear Information System (INIS)

    Fowler, S.W.

    1997-01-01

    Radionuclides entering the ocean from runoff, fallout, or deliberate release rapidly become involved in marine biogeochemical cycles. Sources, sinks and transport of radionuclides and analogue elements are discussed with emphasis placed on how these elements interact with marine organisms. Water, food and sediments are the source terms from which marine biota acquire radionuclides. Uptake from water occurs by surface adsorption, absorption across body surfaces, or a combination of both. Radionuclides ingested with food are either assimilated into tissue or excreted. The relative importance of the food and water pathway in uptake varies with the radionuclide and the conditions under which exposure occurs. Evidence suggests that, compared to the water and food pathways, bioavailability of sediment-bound radionuclides is low. Bioaccumulation processes are controlled by many environmental and intrinsic factors including exposure time, physical-chemical form of the radionuclide, salinity, temperature, competitive effects with other elements, organism size, physiology, life cycle and feeding habits. Once accumulated, radionuclides are transported actively by vertical and horizontal movements of organisms and passively by release of biogenic products, e.g., soluble excreta, feces, molts and eggs. Through feeding activities, particles containing radionuclides are ''packaged'' into larger aggregates which are redistributed upon release. Most radionuclides are not irreversibly bound to such particles but are remineralized as they sink and/or decompose. In the pelagic zones, sinking aggregates can further scavenge particle-reactive elements thus removing them from the surface layers and transporting them to depth. Evidence from both radiotracer experiments and in situ sediment trap studies is presented which illustrates the importance of biological scavenging in controlling the distribution of radionuclides in the water column. (author)

  9. A comparison of patient dose levels between 3/4 vessel conventional angiography and computed tomography angiography during examinations to investigate subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Spanton, David; Strudwick, Ruth M.

    2007-01-01

    The aim of this study was to investigate and compare the levels of ionising radiation dose received by patients whilst undergoing radiological examination for Subarachnoid haemorrhage by conventional angiography (single and bi plane) and computed tomography angiography. The results obtained from previous examinations have been compared to consider which method of investigation delivers the lowest ionising radiation dose to the patient. Consideration was also given to comparing single plane angiography to bi plane angiography as empirical evidence suggested that radiologists received no formal training and only a small amount of informal training on newly installed equipment at the hospital in which the research was carried out. Would this lead to patients being inadvertently exposed to increased radiation as radiologists familiarised themselves with the equipment? The dose received by 30 patients examined for SAH by each modality was converted to effective dose (mSv) for comparison. These results were then further compared by removing the lowest and highest recorded doses to eliminate any bias that may have been caused by skewed data. The results showed that CTA consistently delivered a lower dose to patients than single or bi plane angiography and that bi plane delivered a lower mean average dose than single plane angiography, with or without any skewed data

  10. Fluorescence angiography in retinal tumours

    Energy Technology Data Exchange (ETDEWEB)

    Fuhrmann, M [Staedtisches Klinikum Berlin-Buch (German Democratic Republic)

    1980-01-01

    On the basis of the available photographic material the results of fluorescein angiography are reported in 4 cases of retinoblastoma and 3 cases of Bourneville's disease. The clinical diagnosis of retinoblastoma was confirmed histologically in all cases since the first eye had been removed for the same reason previously. One child had not yet been treated, and in 3 cases radioactive isotopes were used in the treatment. In the group of phacomatosis the patients had only periodical outpatient examinations. The importance of this angiography in the diagnosis and follow-up of these diseases is stressed.

  11. CT and MR angiography

    International Nuclear Information System (INIS)

    Bert, A.L.; Marshal, G.

    1995-01-01

    CT-angiography is a new vessel imaging technique based on the volumetric scanning of the region of interst during the first pass of IV bolus injection of contrast medium. MR-angiography is a titally noninvasive technique. The differentiation of flowing blood from the adjecent stationary tissues is based on the detection of blood motion. The flowing blood is highlighted with white light. CT- and MR-angiographic techniques are used to establish% stenoses and occlusions in intracranial arteries; aneurisms; trombosis of intracranial veins and venous angioma; diseases of neck vessels, thoracic vessels, abdominal vessels. Blood flow direction in cirrotic patients with portal hypertension can be determined in the portal vein, as well as the presence of thrombosis

  12. Transient Global Amnesia following Neural and Cardiac Angiography May Be Related to Ischemia

    Directory of Open Access Journals (Sweden)

    Hongzhou Duan

    2016-01-01

    Full Text Available Introduction. Transient global amnesia (TGA following angiography is rare, and the pathogenesis has not been illustrated clearly till now. The aim of this research is to explore the pathogenesis of TGA following angiography by analyzing our data and reviewing the literature. Methods. We retrospectively studied 20836 cases with angiography in our hospital between 2007 and 2015 and found 9 cases with TGA following angiography. The data of these 9 cases were analyzed. Results. We found all 9 cases with TGA following neural angiography (5 in 4360 or cardiac angiography (4 in 8817 and no case with TGA following peripheral angiography (0 in 7659. Statistical difference was found when comparing the neural and cardiac angiography group with peripheral group (p=0.022. Two cases with TGA were confirmed with small acute infarctions in hippocampus after angiography. This might be related to the microemboli which were rushed into vertebral artery following blood flow during neural angiography or cardiac angiography. There was no statistical difference when comparing the different approaches for angiography (p=0.82 and different contrast agents (p=0.619. Conclusion. Based on the positive findings of imaging study and our analysis, we speculate that ischemia in the medial temporal lobe with the involvement of the hippocampus might be an important reason of TGA following angiography.

  13. Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism : a prospective study

    NARCIS (Netherlands)

    Oudkerk, M; van Beek, EJR; Wielopolski, P; van Ooijen, PMA; Brouwers-Kuyper, EMJ; Bongaerts, AHH; Berghout, A

    2002-01-01

    Background Diagnostic strategies for pulmonary embolism are complex and consist of non-invasive diagnostic tests done to avoid conventional pulmonary angiography as much as possible. We aimed to assess the diagnostic accuracy of magnetic resonance angiography (MRA) for the diagnosis of pulmonary

  14. Radionuclide sorption studies on abyssal red clays

    International Nuclear Information System (INIS)

    Erickson, K.L.

    1979-01-01

    The radionuclide sorption properties of a widely distributed abyssal red clay are being experimentally investigated using batch equilibration techniques. This paper summarizes sorption equilibrium data obtained when 0.68 N NaCl solutions containing either Tc, U, Pu, Am or Cm were contacted with samples of the red clay and also summarizes some initial results from experiments designed to determine the relative selectivity of the clay for various nuclides. Under mildly oxidizing conditions, the sorption equilibrium distribution coefficients for technetium were essentially zero. At solution-phase nuclide concentrations on the order of 10 -6 M and less and at solution pH values of about 6.9, the distribution coefficients for plutonium were about 3 x 10 3 m1/gm and for uranium, americium, and curium were about 10 5 ml/gm or greater. However, at solution pH values of about 2.7, the distribution coefficients for each of the nuclides were greatly diminished. Initial experiments conducted in order to determine the relative selectivity of the clay for cesium, barium, and cerium, indicated that the silicate phases in the clay were selective for cesium over barium and cerium. These experiments also indicated that the hydrous oxide phases were selective for cerium over barium and for barium over cesium

  15. The comparative study on diagnostic validity of cerebral aneurysm by computed tomography angiography versus digital subtraction angiography after subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Masih Saboori

    2011-01-01

    Full Text Available Background: In order to declare the preoperative diagnostic value of brain aneurysms, two radiological modalities, computed tomographic angiography and digital subtraction angiography were compared. Methods: In this descriptive analytic study, diagnostic value of computed tomographic angiography (CTA was com-pared with digital subtraction angiography (DSA. Sensitivity, specificity, positive and negative predictive values were calculated and compared between the two modalities. All data were analyzed with SPSS software, version 16. Results: Mean age of patients was 49.5 ± 9.13 years. 57.9 % of subjects were female. CTA showed 89% sensitivity and 100% specificity whereas DSA demonstrated 74% sensitivity and 100% specificity. Positive predictive value of both methods was 100%, but negative predictive value of CTA and DSA was 85% and 69%, respectively. Conclusions: Based on our data, CTA is a valuable diagnostic modality for detection of brain aneurysm and su-barachnoid hemorrhage.

  16. Investigation of chemical equilibrium kinetics by the electromigration method

    International Nuclear Information System (INIS)

    Bozhikov, G.A.; Ivanov, P.I.; Maslov, O.D.; Dmitriev, S.N.; Bontchev, G.D.; Milanov, M.V.

    2003-01-01

    The measurement of the chemical reaction rates for complex formation as well as hydrolysis type reactions by the method of horizontal zone electrophoresis is outlined. The correlation between chemical equilibrium kinetics and electrodiffusion processes in a constant d.c. electric field is described. In model electromigration experiments the reaction rate constant of the formation a complex by Hf(IV) and diethylenetriaminepentaacetic acid (DTPA) is determined. The electrophoretic mobility, diffusion coefficient and stability constant of the [HfDTPA] - complex are calculated, taking into account experimental electrophoretic data obtained at 298.15±0.05 K and constant ionic strength. No-carrier-added 175 Hf radionuclide was used in electromigration experiments at concentrations of 10 -10 -10 -11 M. (orig.)

  17. On the contents of some radionuclides in precipitation (deposits) of Yerevan city, Armenia

    International Nuclear Information System (INIS)

    Ananyan, V.; Appleby, P.; Danagulyan, A.; Nalbandyan, A.

    2004-01-01

    Biosphere is exposed to cosmic and α -, β -, γ -radiation of numerous radionuclides dispersed in rocks, groundwater, terrestrial water of rivers, seas and oceans, air and biota. The main components of natural radiation are 40 K, 238 U, 232 Th and radioactive products of their decay. The goal of this investigation was to determine radionuclide composition of atmospheric precipitation (deposits) of Yerevan city. For sample collection we used sedimentation method, which covers all deposits on 1 m 2: admixtures, dust and sand fractions during wind (precipitation deposits). The dish made of neutral material (50 x 50 cm) was positioned at a height 1,5 m in a selected sampling site. The bottom of the dish was underlain by filtering paper. The samples were taken monthly. After deposit evaporation and ashing at 450 degree C the deposits were weighed. Total weight of such samples made 41 g for 2000 (12 months). For measurements one sample per season was selected (totally 4 samples). Radionuclide measurements were done on a low-background gamma-spectrometer with Hp Ge semiconductor detector. The exposures of sample measurement and background made 117,34 h each. The sample was positioned close to the detector. After removal of background, radionuclide concentrations were determined. Concentrations of all isotopes of uranium family (234 Th,214 Pb, 214 Bi), except 210 Pb in sample are similar (within the limits of error), so in natural environment they stay in equilibrium. The same is relevant also to radionuclides of thorium family. Concentrations of 210 Pb are almost threefold higher, this deserving further detailed research. Among the remaining isotopes, contents of 40 K are the highest as it greatly contributes to natural radioactive background (N RB). Concentrations of 137 Cs were minimal, as this radionuclide derives only from global man-made environmental pollution. Thus, the results have revealed the radionuclide composition of the sample of atmospheric deposits in

  18. Calculated distribution of radionuclides in soils and sediments

    International Nuclear Information System (INIS)

    Puigdomenech, I.; Bergstroem, U.

    1994-12-01

    The description of the accumulation of radionuclides in some biospheric compartments is in general based on a sorption distribution coefficient K d . This value is very decisive for the concentration of long-lived radionuclides in reservoirs that are important from the dose point of view. Sorption is due to several processes such as ion-exchange and a variety of physical and chemical interactions which are difficult to interpret with the current K d -methodology. In addition, many of the K d values are obtained from laboratory or geospheric conditions not comparable to conditions prevailing in the biosphere. The main objective with this work is to deepen the knowledge about the theoretical background of K d -values. To achieve this purpose, available theoretical models for ion-exchange and surface complexation have been adapted for simulation under biospheric conditions. The elements treated are cesium, radium, neptunium, uranium and plutonium The results show that a triple layer surface complexation model may be used in estimating K d -values for actinides as a function of important chemical parameters such as pH and E H . It is concluded that by estimating some equilibrium constants and making some careful approximations, surface complexation models can be used for performance assessment of radioactive waste repositories. 72 refs, 7 figs

  19. Unusual Congenital Aortic Anomaly with Rare Common Celiamesenteric Trunk Variation: MR Angiography and Digital Substraction Angiography Findings

    International Nuclear Information System (INIS)

    Tosun, Ozgur; Sanlidilek, Umman; Cetin, Huseyin; Ozdemir, Ozcan; Kurt, Aydin; Sakarya, Mehmet Emin; Tas, Ismet

    2007-01-01

    Magnetic resonance angiography and digital substraction angiography (DSA) findings in a case with a rare congenital thoracoabdominal aortic hypoplasia and common celiamesenteric trunk variation with occlusion of infrarenal abdominal aorta are described here. To our knowledge, this aortic anomaly has not been previously described in the English literature. DSA is the optimum imaging modality for determination of aortic hypoplasia, associated vascular malformations, collateral vessels, and direction of flow within vessels

  20. A comparison of radionuclide thyroid angiography, 99mTc-MIBI scintigraphy and power Doppler ultrasonography in the differential diagnosis of solitary cold thyroid nodules

    International Nuclear Information System (INIS)

    Demirel, Koray; Kapucu, Oezlem; Yuecel, Cem; Oezdemir, Hakan; Ayvaz, Goeksun; Taneri, Ferit

    2003-01-01

    We prospectively studied 43 patients with solitary cold thyroid nodules greater than 1.5 cm in diameter to determine the comparative diagnostic value of radionuclide thyroid angiography (RTA), technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) scintigraphy and power Doppler ultrasonography (PDUS) in the differentiation of benign and malignant thyroid nodules. Perfusion of the nodules in RTA was compared with the perfusion in the surrounding normal thyroid tissue and classified as follows: 0, avascular; 1, hypovascular; 2, isovascular; 3, hypervascular. 99m Tc-MIBI uptake in the nodules compared with that in surrounding thyroid tissue was scored for both early and delayed images as follows: 0, cold; 1, decreased; 2, equal; 3, increased. PDUS patterns were classified as nodule vascularisation patterns. The malignancy criteria were set as follows: hypervascular nodule with rapid washout in RTA; complex ring sign with anarchic structure or delta sign in PDUS, and positive retention and increased uptake in the nodule in the early and delayed 99m Tc-MIBI images. These data were compared with the histopathological results. Histology revealed thyroid carcinoma in nine patients (five cases of papillary carcinoma, three of follicular carcinoma and one of medullary carcinoma) and benign conditions in 34 patients (30 cases of nodular goitre, three of lymphocytic thyroiditis and one of follicular adenoma). Sensitivity, specificity and accuracy were, respectively, 0.89, 1.00 and 0.97 for RTA, 1.00, 0.76 and 0.81 for PDUS, and 0.67, 0.91 and 0.86 for 99m Tc-MIBI scintigraphy (when nodules with increased uptake in both the early and the delayed images and a positive retention index were considered as malignant). RTA, 99m Tc-MIBI scintigraphy and PDUS could be helpful in the preoperative assessment of solitary cold thyroid nodules. In this study, RTA was found to be the most accurate and specific method for differentiation of malignant from benign thyroid nodules. (orig.)

  1. Radionuclide Transport Models Under Ambient Conditions

    International Nuclear Information System (INIS)

    Moridis, G.; Hu, Q.

    2000-01-01

    The purpose of this Analysis/Model Report (AMR) is to evaluate (by means of 2-D semianalytical and 3-D numerical models) the transport of radioactive solutes and colloids in the unsaturated zone (UZ) under ambient conditions from the potential repository horizon to the water table at Yucca Mountain (YM), Nevada. This is in accordance with the ''AMR Development Plan U0060, Radionuclide Transport Models Under Ambient Conditions'' (CRWMS M and O 1999a). This AMR supports the UZ Flow and Transport Process Model Report (PMR). This AMR documents the UZ Radionuclide Transport Model (RTM). This model considers: the transport of radionuclides through fractured tuffs; the effects of changes in the intensity and configuration of fracturing from hydrogeologic unit to unit; colloid transport; physical and retardation processes and the effects of perched water. In this AMR they document the capabilities of the UZ RTM, which can describe flow (saturated and/or unsaturated) and transport, and accounts for (a) advection, (b) molecular diffusion, (c) hydrodynamic dispersion (with full 3-D tensorial representation), (d) kinetic or equilibrium physical and/or chemical sorption (linear, Langmuir, Freundlich or combined), (e) first-order linear chemical reaction, (f) radioactive decay and tracking of daughters, (g) colloid filtration (equilibrium, kinetic or combined), and (h) colloid-assisted solute transport. Simulations of transport of radioactive solutes and colloids (incorporating the processes described above) from the repository horizon to the water table are performed to support model development and support studies for Performance Assessment (PA). The input files for these simulations include transport parameters obtained from other AMRs (i.e., CRWMS M and O 1999d, e, f, g, h; 2000a, b, c, d). When not available, the parameter values used are obtained from the literature. The results of the simulations are used to evaluate the transport of radioactive solutes and colloids, and

  2. Development of serial magnification angiography and its clinical significance

    International Nuclear Information System (INIS)

    Sasaki, Tsuneo; Matsubara, Kazuhito; Ishiguchi, Tsuneo; Mashita, Shinichi; Kaii, Osamu

    1979-01-01

    In order to apply serial magnification angiography to clinical examinations so easily, a serial cardioangiography apparatus was equipped with a tube having 0.1 mm focal spot and with DRX-431HD diode. A CAT-FK Type catheter bed (Toshiba) was used as a roentgenographic table and a PUCK film changer was used. Thus, serial magnification angiography can be easily used to clinical examinations, and can be set in a usual x-ray photographic studio. Serial magnification angiography was used to examine the cerebral vessels in 6 patients, vessels of the pulmonary circulation in 1 patient, bronchial arteries in 6 patients, the celiac artery in 18 patients, the superior mesenteric artery in 2 patients, inferior mesenteric artery in 2 patients, the renal artery in 2 patients, and the adrenal vein in 7 patients. Owing to this angiography, minute changes in the vessel in the lesion can be observed and fine neovascularity can be detected. Thus, serial magnification angiography makes diagnoses of vascular disorders easier. (Ichikawa, K.)

  3. A review on studies of the transport and the form of radionuclides in the fluvial environment

    Energy Technology Data Exchange (ETDEWEB)

    Matsunaga, Takeshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-06-01

    The Japan Atomic Energy Research Institute has conducted studies with an aim to contribute to understanding the long-term behavior of atmospherically-derived radionuclides deposited on the ground. The present report reviews a series of studies among them which have especially dealt with the behavior of those radionuclides in a fluvial environment. The studies cited here include investigations of 1) the evaluation of the transport rate of the atmospherically-derived radionuclides from the ground via a river to the downstream areas where the affected water is consumed; 2) the physico-chemical form of the radionuclides in the fluvial environment. An investigation in the Kuji river watershed with {sup 137}Cs, {sup 210}Pb and {sup 7}Be has validated i) the importance of suspended particulate materials in the fluvial discharge of those radionuclides, and ii) a methodology to estimate the discharge of those radionuclides based on the regression analysis with the river water flow rate. From a viewpoint of their distribution between water and suspended particles, the form of radionuclides released by the Chernobyl accident in rivers and lakes in the vicinity of the Chernobyl Nuclear Power Plant were analyzed. As a result, a general reasonability and some cautions were suggested when commonly reported distribution ratios obtained in the laboratory and the different environment are applied to describe the partitioning of the radionuclides in specific natural environmental conditions. This experimental investigation in Chernobyl also revealed the role of natural dissolved organics in affecting the dissolution and transport of {sup 239,240}Pu, {sup 241}Am through complexation to form soluble species. Further, a chemical equilibrium model was applied to describe this complexation. The similar model was also applied for the behavior of iron and manganese (hydr)oxides in river recharged aquifers which can bear riverborne radionuclides and can influence their migration. The

  4. A review on studies of the transport and the form of radionuclides in the fluvial environment

    International Nuclear Information System (INIS)

    Matsunaga, Takeshi

    2001-06-01

    The Japan Atomic Energy Research Institute has conducted studies with an aim to contribute to understanding the long-term behavior of atmospherically-derived radionuclides deposited on the ground. The present report reviews a series of studies among them which have especially dealt with the behavior of those radionuclides in a fluvial environment. The studies cited here include investigations of 1) the evaluation of the transport rate of the atmospherically-derived radionuclides from the ground via a river to the downstream areas where the affected water is consumed; 2) the physico-chemical form of the radionuclides in the fluvial environment. An investigation in the Kuji river watershed with 137 Cs, 210 Pb and 7 Be has validated i) the importance of suspended particulate materials in the fluvial discharge of those radionuclides, and ii) a methodology to estimate the discharge of those radionuclides based on the regression analysis with the river water flow rate. From a viewpoint of their distribution between water and suspended particles, the form of radionuclides released by the Chernobyl accident in rivers and lakes in the vicinity of the Chernobyl Nuclear Power Plant were analyzed. As a result, a general reasonability and some cautions were suggested when commonly reported distribution ratios obtained in the laboratory and the different environment are applied to describe the partitioning of the radionuclides in specific natural environmental conditions. This experimental investigation in Chernobyl also revealed the role of natural dissolved organics in affecting the dissolution and transport of 239,240 Pu, 241 Am through complexation to form soluble species. Further, a chemical equilibrium model was applied to describe this complexation. The similar model was also applied for the behavior of iron and manganese (hydr)oxides in river recharged aquifers which can bear riverborne radionuclides and can influence their migration. The obtained findings and the

  5. Clinical evaluation of right ventricular function using radionuclide method

    International Nuclear Information System (INIS)

    Ishii, Yasushi; Tamaki, Nagayoshi; Mukai, Takao; Motohara, Seiichito; Ikekubo, Katsuji.

    1982-01-01

    Essential thing to evaluate the right ventricular (RV) function is its volumetric measurement. However, its geometrical complexity has hampered this even with the contrast ventriculography, unlike left ventricle (LV). Meanwhile, the radionuclide time-activity curve from the first pass of a tracer through RV in the RAO view provides the most reliable data of the RV ejection fraction (RVEF), same data from the multigated equilibrium study in the LAO view is necessitated for a repeated intervention study, but the latter imposes a critical problem to locate ROI separately in the LAO view. Finally, three dimensional location of RV should be mandatory using new method as the dynamic SPECT in the future. (author)

  6. Fully coupled modeling of radionuclide migration in a clayey rock disturbed by alkaline plume

    International Nuclear Information System (INIS)

    Pellegrni, D.; Windt, L. de; Lee, J.V.D.

    2002-03-01

    The disposal of radioactive wastes in clayey formations may require the use of large amounts of concrete and cement as a barrier to minimize corrosion of steel containers and radionuclide migration and for supporting drifts and disposal vaults. In this context, reactive transport modeling of the interactions between cement or concrete and the argillaceous host rock aims at estimating the evolution in time of the containment properties of the multi-barriers system. The objectives of the paper are to demonstrate that integrating radionuclides migration in the modeling of strongly coupled geochemical processes of cement-clay stone interactions is feasible and that it represents an efficient way to assess the sensitivity and modification of the classical Kd and solubility parameters with respect to the chemical evolutions. Two types of modeling are considered in the paper: i): calculation of intrinsic solubility limits and Kd values backing up on the results of modeling of cement/clay stone interactions (radionuclides are assumed to be present over the whole domain at any time whatever the scenario), ii) full mechanistic modeling which explicitly introduces radionuclides in the calculation with ad hoc assumptions on radionuclide inventory, canister failure, migration pathway, etc. The reactive transport code HYTEC, based on the geochemical code CHESS, is used to simulate both the cement-clay stone interaction processes and the radionuclide migration in 1-D and 2-D configurations. Convective/dispersive and diffuse transport can be simulated for solutes and colloids. A wide range of processes such as aqueous chemistry, redox, dissolution/precipitation, surface complexation and ion exchange can be modeled at equilibrium or with kinetic control. In addition, HYTEC is strongly coupled, i.e. the hydrology (flow and diffusion) may change when mineral precipitation or dissolution changes the local porosity. (authors)

  7. Angiography of the upper extremity

    International Nuclear Information System (INIS)

    Janevski, B.K.

    1982-01-01

    This thesis provides a description of the technical and medical aspects of arteriography of the upper extremity and an extensive analysis of the angiographic anatomy and pathology of 750 selective studies performed in more than 500 patients. A short historical review is provided of angiography as a whole and of arteriography of the hand in particular. The method of percutaneous transfemoral catheterization of the arteries of the upper extremity and particularly the arteries of the hand is considered, discussing the problems the angiographer encounters frequently, describing the angiographic complications which may occur and emphasizing the measures to keep them to a minimum. The use of vasodilators in hand angiography is discussed. A short description of the embryological patterns persisting in the arteries of the arm is included in order to understand the congenital variations of the arteries of the upper extremity. The angiographic patterns and clinical aspects of the most common pathological processes involving the arteries of the upper extremities are presented. Special attention is paid to the correlation between angiography and pathology. (Auth.)

  8. Effective selection of hypertensive patients for angiography

    International Nuclear Information System (INIS)

    van der Voorde, F.; Derkx, F.H.M.; Bossuyt, P.M.M.; Segaar, R.W.; de Wind, A.; Pieterman, H.

    1989-01-01

    The authors prospectively observed 373 severe hypertensives with either diastolic blood pressure (BP) ≥ 105 and age ≤ 40, or BP with three drugs ≥ 105 (regardless of age). Excluded were patients who were older than 75 or who had creatinine >400. History, physical examination, and laboratory data were used to identify high-yield criteria for arteriography. All patients underwent angiography as the gold standard; angiography showed 127 unilateral renal artery stenoses, 73 bilateral renal artery stenoses, and 173 (nonstenosed) essential hypertensives. The authors constructed a logistic regression model of height, weight, age, smoking, and hypertension duration, which could be used to identify 90% of stenosed patients with 50% fewer angiographies in the essential hypertensives

  9. Verification and improvement of predictive algorithms for radionuclide migration

    International Nuclear Information System (INIS)

    Carnahan, C.L.; Miller, C.W.; Remer, J.S.

    1984-01-01

    This research addresses issues relevant to numerical simulation and prediction of migration of radionuclides in the environment of nuclear waste repositories. Specific issues investigated are the adequacy of current numerical codes in simulating geochemical interactions affecting radionuclide migration, the level of complexity required in chemical algorithms of transport models, and the validity of the constant-k/sub D/ concept in chemical transport modeling. An initial survey of the literature led to the conclusion that existing numerical codes did not encompass the full range of chemical and physical phenomena influential in radionuclide migration. Studies of chemical algorithms have been conducted within the framework of a one-dimensional numerical code that simulates the transport of chemically reacting solutes in a saturated porous medium. The code treats transport by dispersion/diffusion and advection, and equilibrium-controlled proceses of interphase mass transfer, complexation in the aqueous phase, pH variation, and precipitation/dissolution of secondary solids. Irreversible, time-dependent dissolution of solid phases during transport can be treated. Mass action, transport, and sorptive site constraint equations are expressed in differential/algebraic form and are solved simultaneously. Simulations using the code show that use of the constant-k/sub D/ concept can produce unreliable results in geochemical transport modeling. Applications to a field test and laboratory analogs of a nuclear waste repository indicate that a thermodynamically based simulator of chemical transport can successfully mimic real processes provided that operative chemical mechanisms and associated data have been correctly identified and measured, and have been incorporated in the simulator. 17 references, 10 figures

  10. Impact assessment of radionuclides released to environment from the European Spallation Source

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, S.; Andersson, K. [Technical University of Denmark (Denmark); Ene, D. [European Spallation Soure AB - ESS, Lund (Sweden)

    2014-07-01

    The European Spallation Source (ESS) is a large science and technology infrastructure project currently under construction in Lund, Sweden, with operation planned by 2019. The facility design and construction includes a linear proton accelerator, a heavy-metal target station, neutron instruments, laboratories, and a data management and software development centre. During operation the ESS will produce a wide range of radionuclides via spallation and activation processes. Radiological assessments are needed to ensure that operational discharges and releases from potential incidents/accidents are within acceptable limits. The spectrum of radionuclides produced at ESS is quite different from that produced in nuclear power plants and assessment work has therefore been challenged by lack of information on less well-known radionuclides. Traditional assessment methodologies have been applied focusing on releases to air and public sewer systems and calculating radiation doses to representative persons living in and near Lund close to the ESS site. Exposure pathways considered include external radiation from radionuclides in air, external radiation from radionuclides deposited on ground and skin, inhalation of radionuclides and ingestion of locally produced contaminated food. Atmospheric dispersion has been simulated with the Gaussian plume model which is considered adequate within a few kilometres. Effects of release height have been investigated and site specific values of other parameters such as wind speed, wind direction, rain fall etc. have been used. Contamination of food has been calculated from the (ECOSYS) food dose model used in the RODOS and ARGOS decision support systems. The food dose model does not contain specific data for a number of ESS relevant radionuclides, e.g. {sup 7}Be, {sup 32}P and {sup 35}S. The data required include mobility of these isotopes, soil-to-plant concentration ratios and equilibrium transfer factors of daily intake by ingestion of meat

  11. Extrapolation of animal radionuclide retention data to man: Use of similarity ratios

    International Nuclear Information System (INIS)

    Thomas, J.M.; Eberhardt, L.L.

    1976-01-01

    A major problem in toxicology is the need for testing a myriad possible substances on several animal species as an aid in establishing standards for man. Particular interest in the problem of extrapolation to man is linked to a need for a method of obtaining transfer coefficients in food-chain models of ecosystems. Such a method could circumvent the necessity to test many species and compounds. Because of their particular interest in radioecology, the authors' studies were initiated using radionuclide retention data available in the literature. Since radionuclide retention should be a function of metabolism it follows that direct or indirect measures could be described by a ''power law'' based on body weight of the organism(s). However, when such power laws have been extended to interspecies comparisons the resulting power coefficients are usually substantially less than the value anticipated and seem to be different for each radionuclide. This paper proposes that interspecies comparisons ought to be based on the proportionality coefficient rather than the power parameter of the power function model and have called pairwise comparisons amongst species ''similarity ratios''. Retention data were examined from five non-ruminant species (including man) where several radionuclides with different physical properties were fed. Subsequently an expression was devised whereby an estimate of biological equilibrium level in man could be calculated using similar estimates from experiments using mice, rats or dogs. There are some statistical questions to resolve which have to do with the assumed frequency distribution for estimates of the proportionality coefficient. In addition, repeated use was made of the same data sets. (author)

  12. Modelling interaction of deep groundwaters with bentonite and radionuclide speciation

    International Nuclear Information System (INIS)

    Wanner, H.

    1986-04-01

    In the safety analysis recently reported for a potential Swiss high-level waste repository, radionuclide speciation and solubility limits are calculated for expected granitic groundwater conditions. This report describes a thermodynamic model which is used to estimate the chemical composition of the pore water in compacted sodium bentonite. The model is based on available experimental data and describes the basic reactions between bentonite and groundwater by an ion-exchange model for sodium, potassium, magnesium, and calcium. The model assumes equilibrium with calcite as long as sufficient carbonates remain in the bentonite, as well as quartz saturation. The long-term situation is modelled by the assumption that the near-field of a deep repository behaves like a mixing tank. It is found that sodium bentonite will slowly be converted to calcium bentonite. The modelled composition of the pore water of compacted sodium bentonite is used to estimate radionuclide solubilities in the near-field of a deep repository. The elements considered are: uranium, neptunium, plutonium, thorium, americium, and technetium. The redox potential in the near-field is assumed to be controlled by the corrosion products of the iron canister. Except for uranium and neptunium, radionuclide solubilities turn out to be lower under the modelled near-field conditions than in the groundwater of the surrounding granitic host rock. Uranium and neptunium solubility might be higher by orders of magnitude in the near-field than in the far-field. From the chemical point of view, calcium bentonite seems to be more stable than sodium bentonite in the presence of Swiss Reference Groundwater. The use of calcium bentonite instead of sodium bentonite will improve the reliability in the prediction of source terms for radionuclide transport in the geosphere. (author)

  13. Radionuclide generators

    International Nuclear Information System (INIS)

    Lambrecht, R.M.; Wollongong Univ.; Tomiyoshi, K.; Sekine, T.

    1997-01-01

    The present status and future directions of research and development on radionuclide generator technology are reported. The recent interest to develop double-neutron capture reactions for production of in vivo generators; neutron rich nuclides for radio-immunotherapeutic pharmaceuticals: and advances with ultra-short lived generators is highlighted. Emphasis is focused on: production of the parent radionuclide; the selection and the evaluation of support materials and eluents with respect to the resultant radiochemical yield of the daughter, and the breakthrough of the radionuclide parent: and, the uses of radionuclide generators in radiopharmaceutical chemistry, biomedical and industrial applications. The 62 Zn → 62 Cu, 66 Ni → 66 Cu, 103m Rh → 103 Rh, 188 W → 188 Re and the 225 Ac → 221 Fr → 213 Bi generators are predicted to be emphasized for future development. Coverage of the 99 Mo → 99m Tc generator was excluded, as it the subject of another review. The literature search ended June, 1996. (orig.)

  14. Magnetic resonance angiography with blood-pool contrast agents: future applications

    International Nuclear Information System (INIS)

    Fink, C.; Goyen, M.; Lotz, J.

    2007-01-01

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  15. Magnetic resonance angiography with blood-pool contrast agents: future applications

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C. [Univ. Hospitals, Grosshadern, Munich (Germany); Goyen, M. [Univ. Medical Center, Hamburg-Eppendorf, Hamburg (Germany); Lotz, J. [Hannover Medical School, Hannover (Germany)

    2007-03-15

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  16. Digital subtraction cerebral angiography by intraarterial injection: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Gould, R.; Norman, D.; Newton, T.H.; Lane, B.

    1983-01-01

    For 4 months, a prototype digital subtraction system was used to obtain images of the cerebral vasculature after intraarterial contrast injections. In 12 instances, the intraarterial injections were recorded with both a digital subtraction unit and conventional direct magnification film-screen system. The digital subtraction and conventional film subtraction images were compared and graded for quality and information content by three skilled observers. In addition, quantitative measurements of contrast-detail performance and spatial resolution were obtained on both the digital system and the screen-film imaging chain. In a clinical setting, both the digital subtraction and conventional film-screen systems provided similar quality images and angiographic information. Contrast-detail curves demonstrated that digital subtraction angiography outperformed conventional film technique for low-contrast objects. Digital subtraction angiography also reduced the time required to obtain the angiogram, markedly reduced film cost, and lowered the contrast agent burden

  17. Equilibrium, kinetic and thermodynamic studies of uranium biosorption by calcium alginate beads

    International Nuclear Information System (INIS)

    Bai, Jing; Fan, Fangli; Wu, Xiaolei; Tian, Wei; Zhao, Liang; Yin, Xiaojie; Fan, Fuyou; Li, Zhan; Tian, Longlong; Wang, Yang; Qin, Zhi; Guo, Junsheng

    2013-01-01

    Calcium alginate beads are potential biosorbent for radionuclides removal as they contain carboxyl groups. However, until now limited information is available concerning the uptake behavior of uranium by this polymer gel, especially when sorption equilibrium, kinetics and thermodynamics are concerned. In present work, batch experiments were carried out to study the equilibrium, kinetics and thermodynamics of uranium sorption by calcium alginate beads. The effects of initial solution pH, sorbent amount, initial uranium concentration and temperature on uranium sorption were also investigated. The determined optimal conditions were: initial solution pH of 3.0, added sorbent amount of 40 mg, and uranium sorption capacity increased with increasing initial uranium concentration and temperature. Equilibrium data obtained under different temperatures were fitted better with Langmuir model than Freundlich model, uranium sorption was dominated by a monolayer way. The kinetic data can be well depicted by the pseudo-second-order kinetic model. The activation energy derived from Arrhenius equation was 30.0 kJ/mol and the sorption process had a chemical nature. Thermodynamic constants such as ΔH 0 , ΔS 0 and ΔG 0 were also evaluated, results of thermodynamic study showed that the sorption process was endothermic and spontaneous. -- Highlights: • Equilibrium, kinetics and thermodynamics of uranium sorption by CaAlg were studied. • Equilibrium studies show that Langmuir isotherm better fit with experimental data. • Pseudo-second-order kinetics model is found to be well depicting the kinetic data. • Thermodynamic study shows that the sorption process is endothermic and spontaneous

  18. Association of actinides with microorganisms and clay: Implications for radionuclide migration from waste-repository sites

    International Nuclear Information System (INIS)

    Ohnuki, T.; Francis, A.; Kozai, N.; Sakamoto, F.; Ozaki, T.; Nankawa, T.; Suzuki, Y.

    2010-01-01

    We conducted a series of basic studies on the microbial accumulation of actinides to elucidate their migration behavior around backfill materials used in the geological disposal of radioactive wastes. We explored the interactions of U(VI) and Pu(VI) with Bacillus subtilis, kaolinite clay, and within a mixture of the two, directly analyzing their association with the bacterium in the mixture by transmission electron microscopy (TEM) and scanning electron microscopy (SEM). The accumulation of U by the mixture rose as the numbers of B. subtilis cells increased. Treating the kaolinite with potassium acetate (CH 3 COOK) removed approximately 80% of the associated uranium while only 65% was removed in the presence of B. subtilis. TEM-EDS analysis confirmed that most of the U taken from solution was associated with B. subtilis. XANES analyses revealed that the oxidation state of uranium associated with B. subtilis, kaolinite, and with the mixture containing both was U(VI). The amount of Pu sorbed by B. subtilis increased with time, but did not reach equilibrium in 48 h; in kaolinite alone, equilibrium was attained within 8 h. After 48 h, the oxidation state of Pu in the solutions exposed to B. subtilis and to the mixture had changed to Pu(V), whereas the oxidation state of the Pu associated with both was Pu(IV). In contrast, there was no change in the oxidation state of Pu in the solution nor on kaolinite after exposure to Pu(VI). SEM-EDS analysis indicated that most of the Pu in the mixture was associated with the bacteria. These results suggest that U(VI) and Pu(VI) preferentially are sorbed to bacterial cells in the presence of kaolinite clay, and that the mechanism of accumulation of U and Pu differs. U(VI) is sorbed directly to the bacterial cells, whereas Pu(VI) first is reduced to Pu(V) and then to Pu(IV), and the latter is associated with the cells. These results have important implications on the migrations of radionuclides around the repository sites of

  19. Fluorescence angiography in retinal tumours

    International Nuclear Information System (INIS)

    Fuhrmann, M.

    1980-01-01

    On the basis of the available photographic material the results of fluorescein angiography are reported in 4 cases of retinoblastoma and 3 cases of Bourneville's disease. The clinical diagnosis of retinoblastoma was confirmed histologically in all cases since the first eye had been removed for the same reason previously. One child had not yet been treated, and in 3 cases radioactive isotopes were used in the treatment. In the group of phacomatosis the patients had only periodical outpatient examinations. The importance of this angiography in the diagnosis and follow-up of these diseases is stressed. (author)

  20. Optimization of Ecg Gating in Quantitative Femoral Angiography

    International Nuclear Information System (INIS)

    Nilsson, S.; Berglund, I.; Erikson, U.; Johansson, J.; Walldius, G.

    2003-01-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase

  1. Optimization of Ecg Gating in Quantitative Femoral Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, S.; Berglund, I.; Erikson, U. [Univ. Hospital, Uppsala (Sweden). Dept. of Oncology, Radiology and Clinical Immunology; Johansson, J.; Walldius, G. [Karolinska Hospital, Stockholm (Sweden). King Gustav V Research Inst.

    2003-09-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase.

  2. Radionuclides in terrestrial ecosystems

    International Nuclear Information System (INIS)

    Allen, S.E.; Horrill, A.D.; Howard, B.J.; Lowe, V.P.W.; Parkinson, J.A.

    1983-07-01

    The subject is discussed under the headings: concentration and spatial distribution of radionuclides in grazed and ungrazed saltmarshes; incorporation of radionuclides by sheep grazing on an estuarine saltmarsh; inland transfer of radionuclides by birds feeding in the estuaries and saltmarshes at Ravenglass; radionuclides in contrasting types of coastal pastures and taken up by individual plant species found in west Cumbria; procedures developed and used for the measurement of alpha and gamma emitters in environmental materials. (U.K.)

  3. Catheter versus non-catheter angiography in isolated third nerve palsy

    International Nuclear Information System (INIS)

    Lee, A.G.

    2007-01-01

    To discuss the controversies surrounding the indications for catheter angiography versus non-catheter and less invasive angiography techniques (e.g. magnetic resonance angiography (MRA) and computerized tomography angiography (CTA)) in the evaluation of patients with a third nerve palsy. Clinical opinion-perspective and literature review. The patient with an isolated third nerve palsy might have a vasculopathic (and typically benign, self limited course) etiology or a life threatening intracranial posterior communicating artery aneurysm. Although it is clear that non-isolated third nerve palsies require imaging directed at the topographical localization of the clinical findings, the evaluation of the neurologically isolated third nerve palsy remains controversial. The completeness of the external (i.e. somatic) motor dysfunction and the presence or absence of internal (i.e. pupillary) dysfunction are generally used to guide the choice of initial neuroimaging. Advances in MRA and CTA technology have reduced but not eliminated our dependence upon catheter angiography in this setting. A properly performed and interpreted MRA or CTA probably will be able to detect greater than 95 % of aneurysms producing a third nerve palsy. The issues surrounding the use of catheter angiography in third nerve palsy are reviewed. If the clinician is highly confident in the capability, availability, and reliability of the neuroradiologist and of their institutional experience and quality of less invasive non-catheter MRA and CTA and if the risk of aneurysm is low or if the risk of angiography is high (e.g. elderly, renal failure, iodinated contrast allergy, risk of stroke) then MRI and MRA (or CTA) may be a reasonable alternative to catheter angiography. Patients with a moderate or uncertain risk of aneurysm and a lower risk for catheter angiography or if there is a low confidence in the quality or the interpretation of the institutional MRA (or CTA) may still require catheter

  4. Radionuclide data

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Chapter 8 presents tables on selected alpha, beta, gamma and x-ray emitters by increasing energy; information on specific activity for selected radionuclides; naturally occurring radionuclides; the natural decay series; and the artificially produced neptunium series. A table of alpha emitters is listed by increasing atomic number and by energy. The table of β emitters presented is useful in identifying β emitters whose energies and possibly half-lives have been determined by standard laboratory techniques. It is also a handy guide to β-emitting isotopes for applications requiring specific half-lives and/or energies. Gamma rays for radionuclides of importance to radiological assessments and radiation protection are listed by increasing energy. The energies and branching ratios are important for radionuclide determinations with gamma spectrometry detectors. This section also presents a table of x-ray energies which are useful for radiochemical analyses. A number of nuclides emit x-rays as part of their decay scheme. These x-rays may be counted with Ar proportional counters, Ge planar or n-type Ge co-axial detectors, or thin crystal NaI(T1) scintillation counters. In both cases, spectral measurements can be made and both qualitative and quantitative information obtained on the sample. Nuclear decay data (energy and probability by radiation type) for more than one hundred radionuclides that are important to health physicists are presented in a schematic manner

  5. Intra-arterial digital subtraction angiography (IA-DSA) with carbon dioxide

    International Nuclear Information System (INIS)

    Takeda, Toshiaki; Ido, Kunio; Yuasa, Yuji

    1988-01-01

    Intra-Arterial Digital Subtraction Angiography (IA-DSA) with Carbon Dioxide (CO 2 ) was performed on 41 patients mainly with liver or renal diseases, and its angiographic manifestation was compared with that of conventional angiography. Although the image quality of the arterial or capillary phase was inferior to that of conventional angiography with iodinated contrast media, the detectablity of arterio-venous shunting was excellent. In fact, DSA with CO 2 revealed the presence of A-V (A-P) shunt in 26 patients (26/41:63.4 % HCC, 13/15:86.7% metastatic liver tumor, 2/3:66.7 % RCC, 1/5:20 %). On the other hand, conventional angiography was able to show in only 5 cases. DSA with CO 2 will become an effective method for detecting minute arterio-venous shunting which can not be demonstrated with conventional angiography. (author)

  6. Comparison between angiography and CT scan in the urologic field

    Energy Technology Data Exchange (ETDEWEB)

    Fujioka, Toshio; Takao, Masaya; Odajima, Kunio; Nakamura, Hiroshi

    1988-02-01

    Seventy-five consecutive patients with urological diseases were examined preoperatively by means of computerized tomography and renal angiography. Classification of the diseases were 53 renal diseases which included renal cell carcinoma, sarcoma, cyst, renal bleeding, arteriovenous fistula, trauma, hydronephrosis and tuberculosis, 11 vesical diseases which included bladder tumor and endometriosis, 9 adrenal diseases which included primary aldosteronism, Cushing syndrome, pheochromocytoma, and metastatic tumor, and 1 case of intra-abdominal testes. For renal diseases, both angiography and CT were useful imaging tools. For vesical diseases, CT was a more useful imaging method but, for adrenal diseases, angiography was superior to CT. CT offers certain advantages over conventional techniques but, in the near future, it may be replaced by MRI. On the contrary, angiography will remain popular for a long time, because angiography is the only way to show which vessels feed organs.

  7. Modelling the behaviour of uranium-series radionuclides in soils and plants taking into account seasonal variations in soil hydrology.

    Science.gov (United States)

    Pérez-Sánchez, D; Thorne, M C

    2014-05-01

    In a previous paper, a mathematical model for the behaviour of (79)Se in soils and plants was described. Subsequently, a review has been published relating to the behaviour of (238)U-series radionuclides in soils and plants. Here, we bring together those two strands of work to describe a new mathematical model of the behaviour of (238)U-series radionuclides entering soils in solution and their uptake by plants. Initial studies with the model that are reported here demonstrate that it is a powerful tool for exploring the behaviour of this decay chain or subcomponents of it in soil-plant systems under different hydrological regimes. In particular, it permits studies of the degree to which secular equilibrium assumptions are appropriate when modelling this decay chain. Further studies will be undertaken and reported separately examining sensitivities of model results to input parameter values and also applying the model to sites contaminated with (238)U-series radionuclides. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Spiral CT angiography of renal arteries: comparison with angiography

    International Nuclear Information System (INIS)

    Wittenberg, G.; Kenn, W.; Tschammler, A.; Sandstede, J.; Hahn, D.

    1999-01-01

    A prospective study was carried out to determine the accuracy of spiral CT angiography (CTA) in the detection of renal artery stenosis (RAS). Eighty-two patients with arterial hypertension underwent CTA and digital subtraction angiography (DSA) to exclude RAS. For CTA a contrast medium bolus of 100-150 ml (flow rate 3 ml/s) was injected. A 24 or 40 s CTA was started at the origin of the superior mesenteric artery after a delay time determined by test bolus injection (collimation = 2 mm, pitch = 1/1.5). For stenosis detection transverse images supported by maximum intensity projections (MIP) or multiplanar reconstruction projections were used. Of 197 renal arteries examined (including 33 accessory arteries), 34 RAS were visualized using DSA. With CTA, one hemodynamic RAS was missed and one additional hemodynamic RAS was found. Sensitivity/specificity was calculated to be 94 %/98 %. For hemodynamically relevant RAS (> 50 %) the sensitivity/specificity was 96 %/99 %. CTA additionally depicted five adrenal masses. The high accuracy rate of RAS detection thus allows the use of CTA as a screening method in patients with arterial hypertension to exclude a renovascular cause. (orig.)

  9. Equilibrium Droplets on Deformable Substrates: Equilibrium Conditions.

    Science.gov (United States)

    Koursari, Nektaria; Ahmed, Gulraiz; Starov, Victor M

    2018-05-15

    Equilibrium conditions of droplets on deformable substrates are investigated, and it is proven using Jacobi's sufficient condition that the obtained solutions really provide equilibrium profiles of both the droplet and the deformed support. At the equilibrium, the excess free energy of the system should have a minimum value, which means that both necessary and sufficient conditions of the minimum should be fulfilled. Only in this case, the obtained profiles provide the minimum of the excess free energy. The necessary condition of the equilibrium means that the first variation of the excess free energy should vanish, and the second variation should be positive. Unfortunately, the mentioned two conditions are not the proof that the obtained profiles correspond to the minimum of the excess free energy and they could not be. It is necessary to check whether the sufficient condition of the equilibrium (Jacobi's condition) is satisfied. To the best of our knowledge Jacobi's condition has never been verified for any already published equilibrium profiles of both the droplet and the deformable substrate. A simple model of the equilibrium droplet on the deformable substrate is considered, and it is shown that the deduced profiles of the equilibrium droplet and deformable substrate satisfy the Jacobi's condition, that is, really provide the minimum to the excess free energy of the system. To simplify calculations, a simplified linear disjoining/conjoining pressure isotherm is adopted for the calculations. It is shown that both necessary and sufficient conditions for equilibrium are satisfied. For the first time, validity of the Jacobi's condition is verified. The latter proves that the developed model really provides (i) the minimum of the excess free energy of the system droplet/deformable substrate and (ii) equilibrium profiles of both the droplet and the deformable substrate.

  10. Doses of external exposure in Jordan house due to gamma-emitting natural radionuclides in building materials.

    Science.gov (United States)

    Al-Jundi, J; Ulanovsky, A; Pröhl, G

    2009-10-01

    The use of building materials containing naturally occurring radionuclides as (40)K, (232)Th, and (238)U and their progeny results in external exposures of the residents of such buildings. In the present study, indoor dose rates for a typical Jordan concrete room are calculated using Monte Carlo method. Uniform chemical composition of the walls, floor and ceiling as well as uniform mass concentrations of the radionuclides in walls, floor and ceiling are assumed. Using activity concentrations of natural radionuclides typical for the Jordan houses and assuming them to be in secular equilibrium with their progeny, the maximum annual effective doses are estimated to be 0.16, 0.12 and 0.22 mSv a(-1) for (40)K, (232)Th- and (238)U-series, respectively. In a total, the maximum annual effective indoor dose due to external gamma-radiation is 0.50 mSv a(-1). Additionally, organ dose coefficients are calculated for all organs considered in ICRP Publication 74. Breast, skin and eye lenses have the maximum equivalent dose rate values due to indoor exposures caused by the natural radionuclides, while equivalent dose rates for uterus, colon (LLI) and small intestine are found to be the smallest. More specifically, organ dose rates (nSv a(-1)per Bq kg(-1)) vary from 0.044 to 0.060 for (40)K, from 0.44 to 0.60 for radionuclides from (238)U-series and from 0.60 to 0.81 for radionuclides from (232)Th-series. The obtained organ and effective dose conversion coefficients can be conveniently used in practical dose assessment tasks for the rooms of similar geometry and varying activity concentrations and local-specific occupancy factors.

  11. Angiography in tumors of cartilaginous genesis

    International Nuclear Information System (INIS)

    Korolev, V.I.

    1986-01-01

    Angiography was used for 122 patients with tumors and tumor-like processes of the cartilage. Angiography was carried out by the S. Seldinger method. Normal angioarchitecture was observed in 16 patients with benign tumors (20 patients), characters of malignant tumor are determined in 4 patients. Normal angioarchitecture is determined in 9.4% of patients with chondrosarcoma (102 patients). The examination carried out showed that angiographic symptotics in chondrosarcomas varied depending on the stage, localization and the degree of morphologic differentiation

  12. Venous digital subtraction angiography for diagnosis of renal artery stenosis in arterial hypertony

    International Nuclear Information System (INIS)

    Schoerner, W.; Kempter, H.; Banzer, D.; Aviles, C.; Weiss, T.; Felix, R.

    1984-01-01

    Venous digital subtraction angiography was performed in 248 patients for the diagnosis of renal arterial stenosis. In 88% of the investigations the stenosis could be found. Comparison of digital angiography and conventional angiography was made for 57 renal arteries (25 investigations). In 52 renal arteries we found the same results with both methods, in 5 renal arteries we found the same results with both methods, in 5 renal arteries the digital angiography showed false positive results. The spatial resolution of digital subtraction angiography is sufficient for the correct diagnosis of significant renal arterial stenosis. With regard to the lower invasion of digital subtraction angiography compared to conventional angiography the first method should be used for clarification of renal arterial hypertension. (orig.)

  13. Radionuclide generators

    International Nuclear Information System (INIS)

    Lambrecht, R.M.

    1983-01-01

    The status of radionuclide generators for chemical research and applications related to the life sciences and biomedical research are reviewed. Emphasis is placed upon convenient, efficient and rapid separation of short-lived daughter radionuclides in a chemical form suitable for use without further chemical manipulation. The focus is on the production of the parent, the radiochemistry associated with processing the parent and daughter, the selection and the characteristic separation methods, and yields. Quality control considerations are briefly noted. The scope of this review includes selected references to applications of radionuclide generators in radiopharmaceutical chemistry, and the life sciences, particularly in diagnostic and therapeutic medicine. The 99 Mo-sup(99m)Tc generator was excluded. 202 references are cited. (orig.)

  14. Microsurgical management of cerebral aneurysms based in CT angiography with three-dimensional reconstruction (3D-CTA) and without preoperative cerebral angiography

    International Nuclear Information System (INIS)

    Gonzalez-Darder, J.M.; Pesudo-Martinez, J.V.; Feliu-Tatay, R.A.

    2001-01-01

    Objective. To study the possibilities of the microsurgical management of ruptured intracranial aneurysms with the sole preoperative information provided by computed tomography angiography with three-dimensional reconstruction (3D-CTA). Methods. Patients were studied with 3D-CTA after diagnosis of subarachnoid hemorrhage. If the study had an adequate quality and revealed an aneurysm congruent with the clinical findings or neurological examination and/or with the location of the bleeding on computed tomography (CT) scan an early microsurgical clipping of the lesion was done. When the quality of the 3D-CTA study was not adequate or the quality being adequate displayed no lesions or the findings were not accurate enough to warrant direct microsurgical treatment, the patient was studied with cerebral digital substraction (DS) angiography. A total of 44 consecutive patients harboring a total of 47 intracranial aneurysms diagnosed by 3D-CTA and without preoperative DS angiography were submitted to microsurgical clipping and included in the study. Results. The overall mortality was 15.9 % and the favorable results evaluated 6 months after discharge by means of the Glasgow outcome scale reached 70.4 %. All lesions were successfully clipped. Surgery was done a mean of 4.1 days after the admission bleeding. A total of four microlesions undiagnosed by 3D-CTA were found at surgery and clipped. Postoperative DS angiography and necropsy findings were also used as control of the 3D-CTA findings but no additional information was provided excepting the finding in DS angiography of an asymptomatic intracavemous aneurysm. Therefore the sensitivity of the 3D-CTA for diagnosis of symtomatic aneurysms was 100 % and the overall sensitivity 90.4 %. Conclusions. We have reached similar results in patients operated on with or without preoperative angiography. 3D-CTA provides very valuable anatomical information, which has an additional value in the microsurgical treatment of aneurysms of the

  15. Comparison between digital subtraction angiography and magnetic resonance angiography in investigation of nonlacunar ischemic stroke in young patients: preliminary results.

    Science.gov (United States)

    Conforto, Adriana Bastos; Fregni, Felipe; Puglia, Paulo; Leite, Claudia da Costa; Yamamoto, Fabio Iuji; Coracini, Karen F; Scaff, Milberto

    2006-06-01

    We preliminarily investigated the relevance of performing digital subtraction angiography (DSA) in addition to magnetic resonance angiography (MRA) in definition of ischemic stroke etiology in young patients. DSAs and MRAs from 17 young patients with nonlacunar ischemic stroke were blindly analyzed and their impact on stroke management was evaluated. Etiologies were the same considering results of either DSA or MRA in 12/17 cases. In 15/17 patients no changes would have been made in treatment, regardless of the modality of angiography considered. These preliminary results suggest that DSA may be redundant in two thirds of ischemic strokes in young patients. Further larger prospective studies are necessary to determine indications of DSA in this age group.

  16. Comparison of gated blood pool SPECT and spiral multidetector computed tomography in the assessment of right ventricular functional parameters. Validation with first-pass radionuclide angiography

    International Nuclear Information System (INIS)

    Lee, Jung S.; Kim, Seong-Jang; Kim, In-Ju; Kim, Yong-Ki; Choo, Ki S.; Lee, Jun S.

    2007-01-01

    The aim of this study was to compare gated blood pool single photon emission computed tomography (SPECT) (GBPS) and multidetector row computed tomography (MDCT) for the determination of right ventricular ejection fraction (RVEF) and right ventricular volumes (RVV) and to compare first-pass radionuclide angiography (FP-RNA) as the gold standard. Twenty consecutive patients (11 men, 9 women) referred for MDCT for the evaluation of the presence of coronary artery disease underwent FP-RNA and GBPS. The mean right ventricular end-diastolic volume (EDV) calculated with GBPS revealed a statistically significant lower value than that of MDCT. The mean right ventricular end-systolic volume (ESV) calculated with GBPS was also lower than that of MDCT. A comparison of right ventricular EDV from GBPS and MDCT yielded a correlation coefficient of 0.5972. Right ventricular ESV between GBPS and MDCT showed a correlation coefficient of 0.5650. The mean RVEFs calculated with FP-RNA (39.8%±4.0%), GBPS (43.7%±6.9%), and MDCT (40.4%±7.7%) showed no statistical differences (Kruskal-Wallis statistics 4.538, P=0.1034). A comparison of RVEFs from FP-RNA and GBPS yielded a correlation coefficient of 0.7251; RVEFs between FP-RNA and MDCT showed a correlation coefficient of 0.6166 and between GBPS and MDCT showed a correlation coefficient of 0.6367. The RVEF, EDV, and ESV calculated by GBPS had good correlation with those obtained with MDCT. In addition, there were no statistical differences of RVEF calculated from FP-RNA, GBPS, and MDCT. However, with regard to RVV, EDV and ESV from GBPS revealed statistically significantly lower values than those of MDCT. Although reasonable correlations among these modalities were obtained, the agreement among these three modalities was not good enough for interchangeable use in the clinical setting. Also, these results should be confirmed in patients with cardiac diseases in future larger population-based studies. (author)

  17. A comparison of radionuclide thyroid angiography, {sup 99m}Tc-MIBI scintigraphy and power Doppler ultrasonography in the differential diagnosis of solitary cold thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Demirel, Koray; Kapucu, Oezlem [Department of Nuclear Medicine, Gazi University School of Medicine, Ankara (Turkey); Yuecel, Cem; Oezdemir, Hakan [Department of Radiology, Gazi University School of Medicine, Ankara (Turkey); Ayvaz, Goeksun [Department of Endocrinology and Metabolic Diseases, Gazi University School of Medicine, Ankara (Turkey); Taneri, Ferit [Department of Surgery, Gazi University School of Medicine, Ankara (Turkey)

    2003-05-01

    We prospectively studied 43 patients with solitary cold thyroid nodules greater than 1.5 cm in diameter to determine the comparative diagnostic value of radionuclide thyroid angiography (RTA), technetium-99m methoxyisobutylisonitrile ({sup 99m}Tc-MIBI) scintigraphy and power Doppler ultrasonography (PDUS) in the differentiation of benign and malignant thyroid nodules. Perfusion of the nodules in RTA was compared with the perfusion in the surrounding normal thyroid tissue and classified as follows: 0, avascular; 1, hypovascular; 2, isovascular; 3, hypervascular. {sup 99m}Tc-MIBI uptake in the nodules compared with that in surrounding thyroid tissue was scored for both early and delayed images as follows: 0, cold; 1, decreased; 2, equal; 3, increased. PDUS patterns were classified as nodule vascularisation patterns. The malignancy criteria were set as follows: hypervascular nodule with rapid washout in RTA; complex ring sign with anarchic structure or delta sign in PDUS, and positive retention and increased uptake in the nodule in the early and delayed {sup 99m}Tc-MIBI images. These data were compared with the histopathological results. Histology revealed thyroid carcinoma in nine patients (five cases of papillary carcinoma, three of follicular carcinoma and one of medullary carcinoma) and benign conditions in 34 patients (30 cases of nodular goitre, three of lymphocytic thyroiditis and one of follicular adenoma). Sensitivity, specificity and accuracy were, respectively, 0.89, 1.00 and 0.97 for RTA, 1.00, 0.76 and 0.81 for PDUS, and 0.67, 0.91 and 0.86 for {sup 99m}Tc-MIBI scintigraphy (when nodules with increased uptake in both the early and the delayed images and a positive retention index were considered as malignant). RTA, {sup 99m}Tc-MIBI scintigraphy and PDUS could be helpful in the preoperative assessment of solitary cold thyroid nodules. In this study, RTA was found to be the most accurate and specific method for differentiation of malignant from benign

  18. Multislice CT Angiography in Renal Artery Stent Evaluation: Prospective Comparison with Intra-Arterial Digital Subtraction Angiography

    International Nuclear Information System (INIS)

    Raza, Syed A.; Chughtai, Aamer R.; Wahba, Mona; Cowling, Mark G.; Taube, David; Wright, Andrew R.

    2004-01-01

    Purpose: To assess the role of multislice computed tomography angiography (MCTA) in the evaluation of renal artery stents, using intra-arterial digital subtraction angiography (DSA) as the gold standard. Methods: Twenty consecutive patients (15 men, 5 women) with 23 renal artery stents prospectively underwent both MCTA and DSA. Axial images, multiplanar reconstructions and maximum intensity projection images were used for diagnosis. The MCTA and DSA images were each interpreted without reference to the result of the other investigation. Results:The three cases of restenosis on DSA were detected correctly by MCTA; in 19 cases where MCTA showed a fully patent stent, the DSA was also negative. Sensitivity and negative predictive value (NPV) of MCTA were therefore 100%. In four cases, MCTA showed apparently minimal disease which was not shown on DSA. These cases are taken as false positive giving a specificity of 80% and a positive predictive value of 43%. Conclusion: The high sensitivity and NPV suggest MCTA may be useful as a noninvasive screen for renal artery stentrestenosis. MCTA detected mild disease in a few patients which was not confirmed on angiography

  19. Radionuclides in radiation-induced bystander effect; may it share in radionuclide therapy?

    Science.gov (United States)

    Widel, M

    2017-01-01

    For many years in radiobiology and radiotherapy predominated the conviction that cellular DNA is the main target for ionizing radiation, however, the view has changed in the past 20 years. Nowadays, it is assumed that not only directed (targeted) radiation effect, but also an indirect (non-targeted) effect may contribute to the result of radiation treatment. Non-targeted effect is relatively well recognized after external beam irradiation in vitro and in vivo, and comprises such phenomena like radiation-induced bystander effect (RIBE), genomic instability, adaptive response and abscopal (out of field) effect. These stress-induced and molecular signaling mediated phenomena appear in non-targeted cells as variety responses resembling that observed in directly hit cells. Bystander effects can be both detrimental and beneficial in dependence on dose, dose-rate, cell type, genetic status and experimental condition. Less is known about radionuclide-induced non-targeted effects in radionuclide therapy, although, based on characteristics of the radionuclide radiation, on experiments in vitro utilizing classical and 3-D cell cultures, and preclinical study on animals it seems obvious that exposure to radionuclide is accompanied by various bystander effects, mostly damaging, less often protective. This review summarizes existing data on radionuclide induced bystander effects comprising radionuclides emitting beta- and alpha-particles and Auger electrons used in tumor radiotherapy and diagnostics. So far, separation of the direct effect of radionuclide decay from crossfire and bystander effects in clinical targeted radionuclide therapy is impossible because of the lack of methods to assess whether, and to what extent bystander effect is involved in human organism. Considerations on this topic are also included.

  20. Synchrotron-based intravenous cerebral angiography in a small animal model

    International Nuclear Information System (INIS)

    Kelly, Michael E; Schueltke, Elisabeth; Fiedler, Stephan; Nemoz, Christian; Guzman, Raphael; Corde, Stephanie; Esteve, Francois; LeDuc, Geraldine; Juurlink, Bernhard H J; Meguro, Kotoo

    2007-01-01

    K-edge digital subtraction angiography (KEDSA), a recently developed synchrotron-based technique, utilizes monochromatic radiation and allows acquisition of high-quality angiography images after intravenous administration of contrast agent. We tested KEDSA for its suitability for intravenous cerebral angiography in an animal model. Adult male New Zealand rabbits were subjected to either angiography with conventional x-ray equipment or synchrotron-based intravenous KEDSA, using an iodine-based contrast agent. Angiography with conventional x-ray equipment after intra-arterial administration of contrast agent demonstrated the major intracranial vessels but no smaller branches. KEDSA was able to visualize the major intracranial vessels as well as smaller branches in both radiography mode (planar images) and tomography mode. Visualization was achieved with as little as 0.5 ml kg -1 of iodinated contrast material. We were able to obtain excellent visualization of the cerebral vasculature in an animal model using intravenous injection of contrast material, using synchrotron-based KEDSA

  1. Value of MR-angiography in brain infarction

    International Nuclear Information System (INIS)

    Pirronello, Veronica; Capizzano, Aristides A.; Chouela, Carolina L.; Ternak, Alejandro; Ramirez, Susana; Mazzuco, Juan C.

    2004-01-01

    A retrospective study has been performed in a series of 237 patients, with brain and neck MR and MR angiography techniques. 108/237 (45.5%) patients presented either hemorrhage or lacunar and non lacunar ischemic stroke, 67 of which showed restricted diffusion. Diffusion and perfusion techniques can significantly contribute to study acute stroke. In our series MR angiography showed a 4% sensitivity to detect small arteries pathology. (author)

  2. The transfer of radionuclides from saltmarsh vegetation to sheep tissues and milk

    Energy Technology Data Exchange (ETDEWEB)

    Beresford, N.A. [Centre for Ecology and Hydrology, CEH-Lancaster, Lancaster Environment Centre, Library Avenue, Bailrigg, Lancaster LA1 4AP (United Kingdom)], E-mail: nab@ceh.ac.uk; Howard, B.J. [Centre for Ecology and Hydrology, CEH-Lancaster, Lancaster Environment Centre, Library Avenue, Bailrigg, Lancaster LA1 4AP (United Kingdom); Mayes, R.W.; Lamb, C.S. [Macaulay Land Use Research Institute, Craigiebuckler, Aberdeen AB15 8QH (United Kingdom)

    2007-11-15

    Radionuclides released into the Irish Sea by the Sellafield reprocessing plant are deposited onto tide-washed pastures along the western coast of the United Kingdom. Many of these pastures are grazed by sheep or cattle. This paper describes a controlled feeding study, in which saltmarsh vegetation harvested from close to the Sellafield plant, was fed to lambs and adult female sheep for a period of 8 weeks. Activity concentrations of {sup 60}Co, {sup 95}Nb, {sup 106}Ru, {sup 134}Cs, {sup 137}Cs, {sup 238}Pu, {sup 239,240}Pu and {sup 241}Am were determined in edible tissues and transfer parameters estimated. The activity concentrations of some of the radionuclides will not have been in equilibrium with those in the diet. Nevertheless, the study was reasonably realistic in terms of agricultural management as the period of the study was similar to that for which lambs graze on the saltmarshes. A field study to determine the activity concentrations of {sup 137}Cs and {sup 239,240}Pu in the milk of ewes grazing a saltmarsh close to Sellafield is also described.

  3. Radionuclides in peat bogs and energy peat; Turvesoiden ja polttoturpeen radionuklidit

    Energy Technology Data Exchange (ETDEWEB)

    Helariutta, K.; Rantavaara, A. [Radiation and Nuclear Safety Authority, Helsinki (Finland); Lehtovaara, J. [Vapo Oy, Jyvaeskylae (Finland)

    2000-06-01

    The study was aimed at improving the general view on radionuclides contents in energy peat produced in Finland. The annual harvest of fuel peat in 1994 was studied extensively. Also thirteen peat bogs used for peat production and one bog in natural condition were analysed for vertical distributions of several radionuclides. These distributions demonstrate the future change in radioactivity of energy peat. Both natural nuclides emitting gamma radiation ({sup 238}U, {sup 235}U, {sup 232}Th, {sup 226}Ra, {sup 40}K) and radiocaesium ({sup 137}Cs, {sup 134}Cs) origin in fallout from a nuclear power plant accident (1986) and in atmospheric nuclear weapon tests were analysed. The beta and alpha active natural nuclides of lead and polonium ({sup 210}Pb, {sup 210}Po) were determined on a set of peat samples. These nuclides potentially contribute to radiation exposure through inhalation when partially released to atmosphere during combustion of peat. The activity concentrations of natural radionuclides often increased towards the deepest peat bog layers whereas the radioactive caesium deposited from atmosphere was missing in the deep layers. In undisturbed surface layers of a natural bog and peat production bogs the contents of {sup 210}Pb and {sup 210}Po exceeded those of the deeper peat layers. The nuclides of the uranium series in the samples were generally not in radioactive equilibrium, as different environmental processes change their activity ratios in peat. Radiation exposure from handling and utilisation of peat ash was estimated with activity indices derived from the data for energy peat harvested in 1994. Intervention doses were exceeded in a minor selection of samples due to {sup 137}Cs, whereas natural radionuclides contributed very little to the doses. (orig.)

  4. Thermodynamic chemical energy transfer mechanisms of non-equilibrium, quasi-equilibrium, and equilibrium chemical reactions

    International Nuclear Information System (INIS)

    Roh, Heui-Seol

    2015-01-01

    Chemical energy transfer mechanisms at finite temperature are explored by a chemical energy transfer theory which is capable of investigating various chemical mechanisms of non-equilibrium, quasi-equilibrium, and equilibrium. Gibbs energy fluxes are obtained as a function of chemical potential, time, and displacement. Diffusion, convection, internal convection, and internal equilibrium chemical energy fluxes are demonstrated. The theory reveals that there are chemical energy flux gaps and broken discrete symmetries at the activation chemical potential, time, and displacement. The statistical, thermodynamic theory is the unification of diffusion and internal convection chemical reactions which reduces to the non-equilibrium generalization beyond the quasi-equilibrium theories of migration and diffusion processes. The relationship between kinetic theories of chemical and electrochemical reactions is also explored. The theory is applied to explore non-equilibrium chemical reactions as an illustration. Three variable separation constants indicate particle number constants and play key roles in describing the distinct chemical reaction mechanisms. The kinetics of chemical energy transfer accounts for the four control mechanisms of chemical reactions such as activation, concentration, transition, and film chemical reactions. - Highlights: • Chemical energy transfer theory is proposed for non-, quasi-, and equilibrium. • Gibbs energy fluxes are expressed by chemical potential, time, and displacement. • Relationship between chemical and electrochemical reactions is discussed. • Theory is applied to explore nonequilibrium energy transfer in chemical reactions. • Kinetics of non-equilibrium chemical reactions shows the four control mechanisms

  5. Postmortem CT Angiography Compared with Autopsy: A Forensic Multicenter Study.

    Science.gov (United States)

    Grabherr, Silke; Heinemann, Axel; Vogel, Hermann; Rutty, Guy; Morgan, Bruno; Woźniak, Krzysztof; Dedouit, Fabrice; Fischer, Florian; Lochner, Stefanie; Wittig, Holger; Guglielmi, Giuseppe; Eplinius, Franziska; Michaud, Katarzyna; Palmiere, Cristian; Chevallier, Christine; Mangin, Patrice; Grimm, Jochen M

    2018-05-01

    Purpose To determine if postmortem computed tomography (CT) and postmortem CT angiography help to detect more lesions than autopsy in postmortem examinations, to evaluate the strengths and weaknesses of each method, and to define their indications. Materials and Methods Postmortem CT angiography was performed on 500 human corpses and followed by conventional autopsy. Nine centers were involved. All CT images were read by an experienced team including one forensic pathologist and one radiologist, blinded to the autopsy results. All findings were recorded for each method and categorized by anatomic structure (bone, organ parenchyma, soft tissue, and vascular) and relative importance in the forensic case (essential, useful, and unimportant). Results Among 18 654 findings, autopsies helped to identify 61.3% (11 433 of 18 654), postmortem CT helped to identify 76.0% (14 179 of 18 654), and postmortem CT angiography helped to identify 89.9% (16 780 of 18 654; P < .001). Postmortem CT angiography was superior to autopsy, especially at helping to identify essential skeletal lesions (96.1% [625 of 650] vs 65.4% [425 of 650], respectively; P < .001) and vascular lesions (93.5% [938 of 1003] vs 65.3% [655 of 1003], respectively; P < .001). Among the forensically essential findings, 23.4% (1029 of 4393) were not detected at autopsy, while only 9.7% (428 of 4393) were missed at postmortem CT angiography (P < .001). The best results were obtained when postmortem CT angiography was combined with autopsy. Conclusion Postmortem CT and postmortem CT angiography and autopsy each detect important lesions not detected by the other method. More lesions were identified by combining postmortem CT angiography and autopsy, which may increase the quality of postmortem diagnosis. Online supplemental material is available for this article.

  6. Neptun: an interactive code for calculating doses to man due to radionuclides in acquatic food chains

    International Nuclear Information System (INIS)

    Zach, Reto.

    1980-07-01

    A flexible and interactive code, NEPTUN, has been written in FORTRAN IV for the PDP-10 computer to assess the impact on man of radionuclides in aquatic food chains. NEPTUN is based on an equilibrium model of the linear-chain type, and calculates aquatic food concentrations and doses to man. A decay term is included for the holdup time of the various food types. A total of seven food types can be selected, which include drinking water, freshwater and salt-water plants, inverebrates and fish. Thirty different diets can be implemented and five different dose factor files can be chosen. These include dose conversion factors for infants and adults based on ICRP 2 and ICRP 26 methodologies. All dose factors involve a dose commitment of 50 years, or equivalently, 50 years of chronic exposure. To date, only stochastic ICRP 26 dose caluclations have been implemented. The basic concentration factor file contains data for 211 different radionuclides; the dose factor files are less comprehensive. However, all files can be readily expanded. The output includes tables of concentrations and doses for individual radionuclides, as well as summaries for groups of radionuclides. Existing aquatic food chain models and the sources of currently-used generic concentration factors are briefly reviewed, and dose factors based on ICRP 2 and ICRP 26 methodologies are contrasted. (auth)

  7. Pediatric angiography

    International Nuclear Information System (INIS)

    Fitz, A.R.

    1987-01-01

    Angiography of the cerebral and visceral arterial systems is performed much less frequently than it was before the advent of computed tomographic scanning (CT). Most institutions have experienced at least a 50% reduction in the number of angiograms performed since installing a CT scanner. However, angiography still plays an important role in the confirmation of diagnoses made using a scanner, and in providing valuable information to the surgeon prior to excision of tumors or the repair of traumatized organs. Recently a number of sophisticated therapeutic procedures requiring vascular catheterization and the injection of contrast agents have been developed. In these procedures catheters are selectively placed in blood vessels perfusing a pathological process, such as an arteriovenous malformation, or at the site of an arterial stenosis; embolization of the arteriovenous malformation or tumor, or dilatation of the stenotic segment, is then performed. Whether the vessel catheterization is for diagnostic or therapeutic purposes, the basic approach is the same, and the technologist's duties are similar. The principal difference between a diagnostic and a therapeutic procedure is the length of time required to carry out the study; therapeutic procedures often require significantly longer periods of general anesthesia or sedation than do diagnostic studies

  8. Radionuclide cardiography in medical practice

    International Nuclear Information System (INIS)

    Strangfeld, D.; Mohnike, W.; Schmidt, J.; Heine, H.; Correns, H.J.

    1986-01-01

    This publication is a compendium on all aspects of radionuclide diagnostics concerning cardiovascular system diseases. Starting with introductory remarks on the control of cardiovascular diseases the contribution of radionuclide cardiology to functional cardiovascular diagnostics as well as pathophysiological and pathobiochemical aspects of radiocardiography are outlined. Radiopharmaceuticals used in radiocardiography, physical and technical problems in application of radionuclides and their measuring techniques are discussed. In individual chapters radionuclide ventriculography, myocardial scintiscanning, circulatory diagnostics, radionuclide diagnostics of arterial hypertension, of thrombosis and in vitro diagnostics of thrombophilia are treated in the framework of clinical medicine

  9. Diagnostic accuracy of multi-slice computed tomographic angiography in the detection of cerebral aneurysms

    International Nuclear Information System (INIS)

    Haghighatkhah, H. R.; Sabouri, S.; Borzouyeh, F.; Bagherzadeh, M. H.; Bakhshandeh, H.; Jalali, A. H.

    2008-01-01

    Multislice computed tomographic angiography is a rapid and minimally invasive method for the detection of intracranial aneurysms. The purpose of this study was to compare Multislice computed tomographic angiography with digital subtraction angiography In the diagnosis of cerebral aneurysms. Patients and Methods: In this cross sectional study we evaluated 111 consecutive patients [42(37.8%) male and 69(62.2%) female], who were admitted under clinical symptoms and signs. suggestive of harboring an intracranial aneurysm by using a four detector Multislice computed tomographic angiography. Then we compared results of Multislice computed tomographic angiography with digital subtraction angiography results as a gold standard method. Digital subtraction angiography was performed by bilateral selective common carotid artery injections and either unilateral or bilateral vertebral artery injections, as necessary. Multislice computed tomographic angiography images were interpreted by one radiologist and digital subtraction angiography was performed by another radiologist who was blinded to the interpretation of the Multislice computed tomographic angiograms. Results: The mean ±S D age of the patients was 49.1±13.6 years (range: 12-84 years). We performed Multislice computed tomographic in 111 and digital subtraction angiography in 85 patients. The sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratio of Multislice computed tomographic angiography, when compared with digital subtraction angiography as the gold standard, were 100%, 90%, 87.5%, 100%, 10 and 0, respectively. Conclusion: Multislice computed tomographic angiography seems to be an accurate and noninvasive imaging modality in the diagnosis of intracranial aneurysms

  10. Angiography in renal tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Doo Suk [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1974-10-15

    Angiographies on forty cases of renal tuberculosis performed at the National Medical Center during a period 1960 through 1970 were reviewed. Abdominal angiography was performed via the femoral route. Some were followed by selective nephroangiography. All patients were subjected to urographyior to angiography. The results of X-ray findings in the forty cases with renal tuberculosis were follows. 1. The age varied 18 to 57 years, average 30.5 years. Twenty one patients were male, and nineteen were female. 2. The right kidney was involved in 17 cases and the left in 15 cases. Both kidneys were involved in 8 cases. 3. Urographic examination revealed pathologic changes in all patients. 4. Focal destruction in the collecting system was the most common finding in the urography of 16 patients. 5. A varying degree of hydronephrosis was present in 15 patients, of whom nine had complained of palpable mass due to hydronephrosis. 6. In the 7 patients with extensive destruction there was no observable excretion contrast medium from the diseased kidney. 7. Angiographic examination was normal in 6 of the 40 patients. 8. Decreased vascularity in the subsegmental or smaller arteries of the affected kidney was the most frequent finding, being found in 34 patients. 9. Occlusion or abrupt termination of the subsegmental arteries was present in 4 patients. 10. Eighteen of the patients had signs of an expansive process within the cavity, the vessels being displaced and stretched around the lesions.

  11. Incidence of ischemic lesions in diffusion-weighted imaging after transbrachial digital subtraction angiography

    International Nuclear Information System (INIS)

    Aschenbach, R.; Majeed, A.; Eger, C.; Basche, S.; Kerl, J.M.; Vogl, T.J.

    2008-01-01

    Purpose: to evaluate the frequency of ischemia after transbrachial digital subtraction angiography under ambulant conditions using diffusion-weighted imaging. Materials and methods: 200 patients were included in a prospective study design and received transbrachial digital subtraction angiography under ambulant conditions. Before and after digital subtraction angiography, diffusion-weighted imaging of the brain was performed. Results: in our study population no new lesions were found in diffusion-weighted imaging after digital subtraction angiography during the 3-hour window after angiography. One new lesion was found 3 days after angiography as a late onset complication. Therefore, the frequency of neurological complications is at the level of the confidence interval of 0 - 1.5%. Conclusion: the transbrachial approach under ambulant conditions is a safe method for digital subtraction angiography resulting in a low rate of ischemic lesions in diffusion-weighted imaging. (orig.)

  12. Metabolism of radionuclides in domestic animals

    International Nuclear Information System (INIS)

    Wirth, E.; Leising, C.

    1986-01-01

    The reactor accident at Chernobyl has shown that shortly after the contamination of the environment radionuclides can be found in animal products. The main contamination pathways of domestic animas are: uptake of radionuclides by foodstuffs; uptake of radionuclides by contaminated drinking water; uptake of radionuclides by inhalation; uptake of radionuclides through skin; uptake of radionuclides by ingestion of soil particles. Generally the uptake of radionuclides by food is the dominant exposure pathway. In rare cases the inhalation of radionuclides or the uptake by drinking water may be of importance. The metabolism of incorporated radionuclides is comparable to the respective metabolism of essential mass or trace elements or heavy metals. Radioisotopes of essential elements are for instance iron 55, manganese 54, cobalt 58 and cobalt 60. Other elements are typical antagonists to essential elements, e.g. strontium 90 is an antagonist to calcium or cesium 137 to potassium. Lead 210 and plutonium 239 behave similarly as heavy metals. Generally the knowledge of the metabolism of trace and mass elements, of antagonistic and synergistic elements and heavy metals can be applied to these radionuclides

  13. Radionuclides sorption in clay soils

    International Nuclear Information System (INIS)

    Siraky, G.; Lewis, C.; Hamlat, S.; Nollmann, C.E.

    1987-01-01

    The sorption behaviour of clay soils is examined through a parametric study of the distribution coefficient (Kd) for the radionuclides of interest, Cs and Sr. This work is a preliminary stage of the migration studies of these nuclides in a porous medium (ground of Ezeiza, Argentina) and the evaluation of radiologic impact of the removal of low and intermediate activity wastes in shallow trenches. The determination of Kd is performed by a static technique or batch. The phases are separated by centrifugation at 20000 g during 1 hour. The activity of supernatant solution of Cs-137 and Sr-85 is measured in a detecting system of I Na(Tl) well-type. Two types of parameters were changed: a) those related to the determination method: phase separation (centrifugation vs. centrifugation plus filtration); equilibrium period, ratio solid/liquid; b) those related to the geochemical system: pH of contact solution, carrier concentration, competitive ions, ionic strength, desorption. It was observed that the modification of parameters in the Kd-measurement does not change the order of magnitude of results. (Author)

  14. Radionuclide scanning

    International Nuclear Information System (INIS)

    Shapiro, B.

    1986-01-01

    Radionuclide scanning is the production of images of normal and diseased tissues and organs by means of the gamma-ray emissions from radiopharmaceutical agents having specific distributions in the body. The gamma rays are detected at the body surface by a variety of instruments that convert the invisible rays into visible patterns representing the distribution of the radionuclide in the body. The patterns, or images, obtained can be interpreted to provide or to aid diagnoses, to follow the course of disease, and to monitor the management of various illnesses. Scanning is a sensitive technique, but its specificity may be low when interpreted alone. To be used most successfully, radionuclide scanning must be interpreted in conjunction with other techniques, such as bone radiographs with bone scans, chest radiographs with lung scans, and ultrasonic studies with thyroid scans. Interpretation is also enhanced by providing pertinent clinical information because the distribution of radiopharmaceutical agents can be altered by drugs and by various procedures besides physiologic and pathologic conditions. Discussion of the patient with the radionuclide scanning specialist prior to the study and review of the results with that specialist after the study are beneficial

  15. Internal Dosimetry Monitoring- Detection Limits for a Selected Set of Radionuclides and Their Translation Into Committed Effective Dose

    International Nuclear Information System (INIS)

    Brandl, A.; Hrnecek, E.; Steger, F.

    2004-01-01

    To harmonize the practice of internal dosimetry monitoring across the country, the Austrian Standards Institute is currently drafting a new set of standards which are concerned with occupational incorporation monitoring of individuals handling non-sealed radioactive material. This set of standards is expected to consist of three parts discussing the general necessity and frequency, the requirements for monitoring institutions, and the determination and rigorous calculation of committed effective dose after incorporation of radioactive material, respectively. Considerations of the requirements for routine monitoring laboratories have led to an evaluation of the detection limits for routine monitoring equipment. For a selected set of radionuclides, these detection limits are investigated in detail. The main emphasis is placed on the decay chains of naturally occurring radionuclides showing some significant potential for being out of equilibrium due to chemical processes in certain mining industries. The radionuclides considered in this paper are 226Ra, 228Ra, 228Th, 232Th, 234U, 235U, and 238U. Given the routine monitoring intervals of the Austrian Standard, these detection limits are translated into information on committed effective dose. This paper investigates whether routine monitoring equipment is sufficient to ensure compliance with EC directive 96/29/Euratom for this selected set of radionuclides. (Author) 9 refs

  16. Assessment of the equilibrium of Th-228 and Ra-228 by gamma-ray spectrometry in mangrove soils

    International Nuclear Information System (INIS)

    Paiva, Jose Daniel S.; Farias, Emerson E.G.; Franca, Elvis J. De

    2015-01-01

    The mangrove environment consists of soil containing high organic matter, characterized by the influence of continental and oceanic waters, relatively high concentrations of salts and exuberant vegetation. Mangroves also present high dynamics of chemical compound cycling, in which soils become quite relevant due to the influence of continental and oceanic sediments. Taking into account the different sources and transport of radionuclides within the mangrove environment, this study focused at the radioactive equilibrium of Thorium-232 series radionuclides, especially the Ra-228 and Thorium-228. For this, soil samples were collected in the crown projection of tree species from two mangroves located in the municipalities of Olinda/Recife and Rio Formoso, Pernambuco State, Brazil. The material was oven-dried and milled and test portions of 38 g were transferred to cylindrical vials and sealed. After 30 days, the natural radioactivity was measured during 80,000 seconds using High Resolution Gamma-Ray Spectrometry with a germanium detector of 2.2 keV of resolution at the 1,332 keV Co-60 photopeak. For Ra-228 determination, 911 keV gamma-ray line (Ac-228) were employed, while 238 keV (Pb-212) and 727 keV (Bi-212) were considered for estimating activity concentrations of Th-228. As a result, Ra-228 and Th 228 were in equilibrium since the activity concentrations (ranging from 35 Bq/kg to 50 Bq/kg) were not significantly different at the 95% confidence level. The results have confirmed that, even for environments of high dynamics such as mangroves, radioactive equilibrium of Th-228 and Ra-228 was kept, corroborating Th-232 determination in mangrove soils. (author)

  17. Assessment of the equilibrium of Th-228 and Ra-228 by gamma-ray spectrometry in mangrove soils

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, Jose Daniel S.; Farias, Emerson E.G.; Franca, Elvis J. De, E-mail: paivajds@gmail.com, E-mail: emersonemiliano@yahoo.com.br, E-mail: ejfranca@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2015-07-01

    The mangrove environment consists of soil containing high organic matter, characterized by the influence of continental and oceanic waters, relatively high concentrations of salts and exuberant vegetation. Mangroves also present high dynamics of chemical compound cycling, in which soils become quite relevant due to the influence of continental and oceanic sediments. Taking into account the different sources and transport of radionuclides within the mangrove environment, this study focused at the radioactive equilibrium of Thorium-232 series radionuclides, especially the Ra-228 and Thorium-228. For this, soil samples were collected in the crown projection of tree species from two mangroves located in the municipalities of Olinda/Recife and Rio Formoso, Pernambuco State, Brazil. The material was oven-dried and milled and test portions of 38 g were transferred to cylindrical vials and sealed. After 30 days, the natural radioactivity was measured during 80,000 seconds using High Resolution Gamma-Ray Spectrometry with a germanium detector of 2.2 keV of resolution at the 1,332 keV Co-60 photopeak. For Ra-228 determination, 911 keV gamma-ray line (Ac-228) were employed, while 238 keV (Pb-212) and 727 keV (Bi-212) were considered for estimating activity concentrations of Th-228. As a result, Ra-228 and Th 228 were in equilibrium since the activity concentrations (ranging from 35 Bq/kg to 50 Bq/kg) were not significantly different at the 95% confidence level. The results have confirmed that, even for environments of high dynamics such as mangroves, radioactive equilibrium of Th-228 and Ra-228 was kept, corroborating Th-232 determination in mangrove soils. (author)

  18. Electrocardiographically gated snapshot MR angiography

    International Nuclear Information System (INIS)

    Brown, D.G.; Holsinger, A.E.; Riederer, S.J.

    1990-01-01

    The purpose of this paper is to evaluate the effectiveness of applying ultrashort (∼12 msec) TR times and measuring the central phase encodings first in improving the accuracy of vascular depiction in MR angiography. The imaging method combines ultrashort TR imaging techniques with time-of-flight MR angiography. The central phase-encoding views are acquired first, and an inversion-recovery contrast preparation pulse is applied prior to image acquisition to null signal from static tissues. In initial studies, the method was tested on phantoms and volunteers. The contrast-preparation phase effectively nulls static spins at the start of image acquisition. During the TL period fresh blood flows into the imaging section; even slowly moving blood is fully replaced

  19. Evaluation of spinal cord vessels using multi-slice CT angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Zhu Ruijiang; Feng Xiaoyuan

    2006-01-01

    Objective: To evaluate the value of Multi-slice spiral CT angiography for spinal cord vessels. Methods: 11 adult subjects with suspected of myelopathy were performed with Multi-slice spiral CT angiography, An iodine contrast agent was injected at 3.5 ml/s, for total 100 ml. The parameters were axial 16 slice mode, 0.625 mm slice thickness, 0.8 s rotation, delay time depending on smartprep(15-25 s), multi-phase scan. The coronal and sagittal MPR and SSD were generated on a workstation compared with spinal digital subtraction angiography (DSA) to analyze normal or abnormal spinal cord vessels. Results: Normal findings at spinal CTA and digital subtraction angiography in six adult normal subjects and spinal cord vascular malformations (1 intradural extramedullary AVF, 4 dural AVFs) in five cases, Recognizable intradural vessels corresponding to anterior median (midline) veins and/or anterior spinal arteries were show in six adult normal subjects. Abnormal intradural vessels were detected in all five spinal cord vascular malformation with CT angiography, in comparison with digital subtraction angiography these vessels were primarily enlarged veins of the coronal venous plexus on the cord surface, radiculomedullary-dural arteries could not be clearly shown in four dural AVF, only one anterior spinal artery was detected in one patient with intradural medullary AVF, which direct shunt between anterior spinal artery and perimedullary vein with tortuous draining vessel. Conclusion: Multi-slice CT angiography is able to visualize the normal or abnormal spinal cord vessels. It could be used as a noninvasive method to screen the spinal cord vascular disease. (authors)

  20. [Radioisotopic mapping of the arrhythmogenic focus in patients with chronic chagasic cardiomyopathy and sustained ventricular tachycardia].

    Science.gov (United States)

    de Paola, A A; Balbão, C E; Castiglioni, M L; Barbieri, A; Mendonça, A; Netto, O S; Guiguer Júnior, N; Vattimo, A C; Souza, I A; Portugal, O P

    1993-06-01

    To localize the site of the origin of sustained ventricular tachycardia in chronic chagasic cardiomyopathy patients refractory to antiarrhythmic therapy by radionuclide angiography techniques. Five patients underwent radionuclide angiography by intravenous administration of 25mCi 99mTc. The images were obtained in sinus rhythm and during sustained ventricular tachycardia induced in the electrophysiologic laboratory for endocardial mapping. Amplitude and phase images were obtained resulting in a contraction wave synchronic to ventricular dispolarization. All patients had haemodynamic stability during the arrhythmia. One patient had incessant ventricular tachycardia. Mean ejection fraction was 0.38. In 4 patients the site of the origin of ventricular tachycardia was posterior and in one it was localized in the interventricular septum. There was identity in the site of the origin of ventricular tachycardia obtained by endocardial mapping or radionuclide angiography in all patients. The therapy was chemical ablation in 3 patients, surgical aneurysmectomy in one and pharmacologic therapy in the last patient. The site of the origin of ventricular tachycardia can be estimated by analyzing the contraction wave obtained by radionuclide angiography techniques in patients with hemodynamic stable sustained ventricular tachycardia.

  1. Drift-Scale Radionuclide Transport

    International Nuclear Information System (INIS)

    Houseworth, J.

    2004-01-01

    The purpose of this model report is to document the drift scale radionuclide transport model, taking into account the effects of emplacement drifts on flow and transport in the vicinity of the drift, which are not captured in the mountain-scale unsaturated zone (UZ) flow and transport models ''UZ Flow Models and Submodels'' (BSC 2004 [DIRS 169861]), ''Radionuclide Transport Models Under Ambient Conditions'' (BSC 2004 [DIRS 164500]), and ''Particle Tracking Model and Abstraction of Transport Process'' (BSC 2004 [DIRS 170041]). The drift scale radionuclide transport model is intended to be used as an alternative model for comparison with the engineered barrier system (EBS) radionuclide transport model ''EBS Radionuclide Transport Abstraction'' (BSC 2004 [DIRS 169868]). For that purpose, two alternative models have been developed for drift-scale radionuclide transport. One of the alternative models is a dual continuum flow and transport model called the drift shadow model. The effects of variations in the flow field and fracture-matrix interaction in the vicinity of a waste emplacement drift are investigated through sensitivity studies using the drift shadow model (Houseworth et al. 2003 [DIRS 164394]). In this model, the flow is significantly perturbed (reduced) beneath the waste emplacement drifts. However, comparisons of transport in this perturbed flow field with transport in an unperturbed flow field show similar results if the transport is initiated in the rock matrix. This has led to a second alternative model, called the fracture-matrix partitioning model, that focuses on the partitioning of radionuclide transport between the fractures and matrix upon exiting the waste emplacement drift. The fracture-matrix partitioning model computes the partitioning, between fractures and matrix, of diffusive radionuclide transport from the invert (for drifts without seepage) into the rock water. The invert is the structure constructed in a drift to provide the floor of the

  2. Chapter 2. Radionuclides in the biosphere

    International Nuclear Information System (INIS)

    Toelgyessy, J.; Harangozo, M.

    2000-01-01

    This is a chapter of textbook of radioecology for university students. In this chapter authors deal with role of radionuclides in the biosphere. Chapter consists of next parts: (1) Natural radionuclides in biosphere; (2) Man-made radionuclides in the biosphere; (3) Ecologically important radionuclides; (4) Natural background; (5) Radiotoxicity and (6) Paths of transfer of radionuclides from the source to human

  3. Clinical utility and cost-effectiveness of CT-angiography in the diagnosis of nontraumatic subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Jabbarli, Ramazan; Shah, Mukesch; Hippchen, Beate; Velthoven, Vera van [University Hospital of Freiburg, Department of Neurosurgery, Freiburg/Breisgau (Germany); Taschner, Christian [University Hospital of Freiburg, Department of Neuroradiology, Freiburg (Germany); Kaier, Klaus [University Hospital of Freiburg, Institute for Medical Biometry and Medical Informatics, Freiburg (Germany)

    2014-10-15

    CT-angiography gains an increasing role in the initial diagnosis of patients with nontraumatic subarachnoid hemorrhage (SAH). However, the implementation of CT-angiography does not always exclude the necessity of conventional angiography. Our objective was to determine the practical utility and cost-effectiveness of CT-angiography. All patients with nontraumatic subarachnoid hemorrhage admitted to our university hospital after implementation of CT-angiography between June 1, 2011 and June 30, 2012 were retrospectively analyzed in regard to factors of treatment flow, radiation exposure, harms of contrast medium loading, and diagnostic costs. A control group of the same size was assembled from previously admitted SAH patients, who did not undergo pretreatment CT-angiography. Furthermore, cost-effectiveness analysis was performed. The final analysis consisted of 93 patients in each group. Of 93 patients with pretreatment CT-angiography, 74 had to undergo conventional angiography for diagnostic and/or therapeutic purposes. CT-angiography had significant impact on the reduction of collective effective radiation dose by 4.419 mSv per person (p = 0.0002) and was not associated with additional harms. Despite the significantly earlier detection of aneurysms with CT-angiography (p < 0.0001), there were no significant differences in the timing of aneurysm repair and duration of ICU and general hospital stay. There was an increase of diagnostic costs - the cost-effectiveness analysis showed, however, that benefits of CT-angiography in respect to radiation exposure and risk of conventional angiography-related complications justify the additional costs of CT-angiography. Although the implementation of CT-angiography in SAH diagnosis cannot completely replace conventional angiography, it can be approved in regard to radiation hygiene and cost-effectiveness. (orig.)

  4. Magnetic resonance angiography of fetal vasculature at 3.0 T

    OpenAIRE

    Neelavalli, Jaladhar; Krishnamurthy, Uday; Jella, Pavan K.; Mody, Swati S.; Yadav, Brijesh K.; Hendershot, Kelly; Hernandez-Andrade, Edgar; Yeo, Lami; Cabrera, Maria D.; Haacke, Ewart M.; Hassan, Sonia S.; Romero, Roberto

    2016-01-01

    Magnetic resonance angiography has not been used much previously for visualizing fetal vessels in utero for reasons that include a contraindication for the use of exogenous contrast agents, maternal respiratory motion and fetal motion. In this work, we report the feasibility of using an appropriately modified clinical time-of-flight magnetic resonance imaging sequence for non-contrast angiography of human fetal and placental vessels at 3.0 T. Using this 2D angiography technique, it is possibl...

  5. Studies on migration behavior of radionuclides under reducing conditions in JNC

    International Nuclear Information System (INIS)

    Kitamura, A.; Sato, H.

    2002-01-01

    Japan Nuclear Cycle Development Institute (JNC) has performed extensive researches and developments to investigate the geochemistry and radionuclide migration in buffer materials and geosphere. Experimental and modeling studies have been carried out related to the geological disposal of high-level radioactive waste (HLW) as a link in the chair of a follow-up of the second progress report, which has explained in the technical feasibility of HLW geological disposal in Japan. In this paper, three experimental studies on solubility, sorption and diffusion of radionuclides under reducing conditions for assuring the reliability and for improving the quality of the databases are introduced. Solubility and sorption behavior of neptunium (Np) have been studied under reducing conditions in carbonate media. For the solubility study, thermodynamic equilibrium constants of carbonatohydroxo complexes of Np(IV) have been determined from a solubility measurement in alkaline solutions. For the sorption study, distribution coefficient (K d ) of Np onto smectite has been determined in weak alkaline solutions under reducing conditions in carbonate media. For the diffusion study, apparent diffusivity (D a ) of selenium (Se) in compacted bentonite have been determined under reducing conditions as a function of silica sand content and temperature

  6. Diagnostic accuracy of CT angiography in acute gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Chua, A. E.; Ridley, L. J.

    2008-01-01

    Full text: The aim of the study was to carry out a systematic review determining the accuracy of CT angiography in the diagnosis of acute gastrointestinal bleeding. A search of published work in Medline and manual searching of reference lists of articles was conducted. Studies were included if they compared CT angiography to a reference standard of upper gastrointestinal endoscopy, colonoscopy, angiography or surgery in the diagnosis of acute gastrointestinal bleeding. Eight published studies evaluating 129 patients were included. Data were used to form 2 x2 tables. Computed tomography angiography showed pooled sensitivity of 86% (95% confidence interval 78-92%) and specificity of 95% (95% confidence interval 76-100%), without showing significant heterogeneity (x 2 = 3.5, P=0.6) and (x 2 - 5.4, P = 0.6), respectively. Summary receiver operating characteristic analysis showed an area under the curve of 0.93. Computed tomography angiography is accurate in the diagnosis of acute gastrointestinal bleeding and can show the precise location and aetiology of bleeding, thereby directing further management. Strong recommendations for use of CT cannot be made from this review because of the methodological limitations and further large prospective studies are needed to define the role of CT in acute gastrointestinal bleeding.

  7. Geomorphological applications of environmental radionuclides

    International Nuclear Information System (INIS)

    Quine, T.A.; Walling, D.

    1998-01-01

    Geomorphologists have shown increasing interest in environmental radionuclides since pioneering studies by Ritchie and McHenry in the USA and Campbell, Longmore and Loughran in Australia. Environmental radionuclides have attracted this interest because they provide geomorphologists with the means to trace sediment movement within the landscape. They, therefore, facilitate investigation of subjects at the core of geomorphology, namely the rates and patterns of landscape change. Most attention has been focussed on the artificial radionuclide caesium-137 ( 137 Cs) but more recently potential applications of the natural radionuclides lead-210 ( 210 Pb) and beryllium-7( 7 Be) have been investigated (Walling et al., 1995; Wallbrink and Murray, 1996a, 1996b). The origin, characteristics and applications of these radionuclides are summarised. These radionuclides are of value as sediment tracers because of three important characteristics: a strong affinity for sediment; a global distribution and the possibility of measurement at low concentration. Geomorphological applications of environmental radionuclides provide unique access to detailed qualitative data concerning landscape change over a range of timescales

  8. Foodstuffs, radionuclides, monitoring

    International Nuclear Information System (INIS)

    Denisikov, A.I.

    2000-01-01

    Radionuclide contamination of water and food stuffs as a result of the Chernobyl accident and permissible contents of 90 Sr and 137 Cs are considered in brief. A method of radiation monitoring of food stuffs and water for the radionuclides mentioned is suggested. The method permits employment of the simplest and cheapest radiometric equipment for analysis, whole the high degree of radionuclide concentration using fiber sorbents permits using the instrumentation without expensive shields against external radiation. A description of ion-exchange unit for radiation monitoring of liquid samples of food stuffs or water, is provided [ru

  9. Generator for radionuclide

    International Nuclear Information System (INIS)

    Weisner, P.S.; Forrest, T.R.F.

    1985-01-01

    This invention provides a radionuclide generator of the kind in which a parent radionuclide, adsorbed on a column of particulate material, generates a daughter radionuclide which is periodically removed from the column. This invention is particularly concerned with technetium generators using single collection vials. The generator comprises a column, a first reservoir for the eluent, a second reservoir to contain the volume of eluent required for a single elution, and means connecting the first reservoir to the second reservoir and the second reservoir to the column. Such a generator is particularly suitable for operation by vacuum elution

  10. Usefulness of MR angiography in renal tumor

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Toshitsugu; Morimoto, Kouji; Nishimura, Kenji; Tsujimura, Akira; Yasunaga, Yutaka; Matsumiya, Kiyomi; Takaha, Minato (Osaka National Hospital (Japan))

    1992-11-01

    MR angiography using a gradient-echo, pulse sequence FLASH (fast, low-angle shot) method during breath-hold with a MAGNETOM H-15 scanner (1.5 Tesla; Siemens Medical System) was performed on 27 patients with renal tumor at our clinic between Feburary 20, 1990 and September 30, 1991 and we studied to evaluate its usefulness. Of these 27 patients, 22 patients including one patient under hemodialysis treatment had renal cell carcinoma and one patient had oncocytoma pathologically proven from the excised specimens. The remaining four patients including two patients associated with inferior vena cava tumor thrombus were clinically diagnosed as renal cell carcinoma based on the result of imaging examinations such as excretory urography, ultrasonography, computed tomography and conventional angiography. However, they could not be operated on because their tumors were too advanced. By reconstruction of the data of consecutive coronal scans of the abdominal blood vessels such as the abdominal aorta, inferior vena cava and renal arteries and veins simultaneously without any intravenous contrast materials. Our present study revealed that MR angiography has some advantages, especially with regard to preoperative angiographic information about the abdomen of patients with renal tumor. That is, MR angiography can delineate many kinds of arteries and veins of the abdomen simultaneously and in a broader range, as well as it can be performed on the patients with hypersensitivity to iodinate contrast materials or renal insufficiency in a usual fashion. Furthermore, our present study suggested that the MR angiography is useful for assessing the presence and extent of inferior vena caval tumor thrombus of renal cell carcinoma and for clearly distinguishing tumor lesion and the surrounding normal renal parenchyma in the patients with renal tumor. (author).

  11. Usefulness of MR angiography in renal tumor

    International Nuclear Information System (INIS)

    Oka, Toshitsugu; Morimoto, Kouji; Nishimura, Kenji; Tsujimura, Akira; Yasunaga, Yutaka; Matsumiya, Kiyomi; Takaha, Minato

    1992-01-01

    MR angiography using a gradient-echo, pulse sequence FLASH (fast, low-angle shot) method during breath-hold with a 'MAGNETOM H-15' scanner (1.5 Tesla; Siemens Medical System) was performed on 27 patients with renal tumor at our clinic between Feburary 20, 1990 and September 30, 1991 and we studied to evaluate its usefulness. Of these 27 patients, 22 patients including one patient under hemodialysis treatment had renal cell carcinoma and one patient had oncocytoma pathologically proven from the excised specimens. The remaining four patients including two patients associated with inferior vena cava tumor thrombus were clinically diagnosed as renal cell carcinoma based on the result of imaging examinations such as excretory urography, ultrasonography, computed tomography and conventional angiography. However, they could not be operated on because their tumors were too advanced. By reconstruction of the data of consecutive coronal scans of the abdominal blood vessels such as the abdominal aorta, inferior vena cava and renal arteries and veins simultaneously without any intravenous contrast materials. Our present study revealed that MR angiography has some advantages, especially with regard to preoperative angiographic information about the abdomen of patients with renal tumor. That is, MR angiography can delineate many kinds of arteries and veins of the abdomen simultaneously and in a broader range, as well as it can be performed on the patients with hypersensitivity to iodinate contrast materials or renal insufficiency in a usual fashion. Furthermore, our present study suggested that the MR angiography is useful for assessing the presence and extent of inferior vena caval tumor thrombus of renal cell carcinoma and for clearly distinguishing tumor lesion and the surrounding normal renal parenchyma in the patients with renal tumor. (author)

  12. Process for encapsulating radionuclides

    International Nuclear Information System (INIS)

    Brownell, L.E.; Isaacson, R.E.

    1976-01-01

    Radionuclides are immobilized in virtually an insoluble form by reacting at a temperature of at least 90 0 C as an aqueous alkaline mixture having a solution pH of at least 10, containing a source of silicon, the radionuclide waste, and a metal cation. The molar ratio of silicon to the metal cation is on the order of unity to produce a gel from which complex metalosilicates crystallize to entrap the radionuclides within the resultant condensed crystal lattice. The product is a silicious stone-like material which is virtually insoluble and nonleachable in alkaline or neutral environment. One embodiment provides for the formation of the complex metalo-silicates, such as synthetic pollucite, by gel formation with subsequent calcination to the solid product; another embodiment utilizes a hydrothermal process, either above ground or deep within basalt caverns, at greater than atmospheric pressures and a temperature between 90 and 500 0 C to form complex metalo-silicates, such as strontium aluminosilicate. Another embodiment provides for the formation of complex metalo-silicates, such as synthetic pollucite, by slurrying an alkaline mixture of bentonite or kaolinite with a source of silicon and the radionuclide waste in salt form. In each of the embodiments a mobile system is achieved whereby the metalo-silicate constituents reorient into a condensed crystal lattice forming a cage structure with the condensed metalo-silicate lattice which completely surrounds the radionuclide and traps the radionuclide therein; thus rendering the radionuclide virtually insoluble

  13. Radiosurgery for arteriovenous malformations based on magnetic resonance angiography

    International Nuclear Information System (INIS)

    Mehta, Minesh; Kubsad, Shrikant; Petereit, Daniel; Turski, Patrick; Levin, Allan; Kinsella, Timothy

    1993-01-01

    Magnetic Resonance Angiography (MRA) was performed to establish its feasibility, compare it with standard angiography (SA), employ MRA in follow-up and semiquantify AVM flow velocity (FV). A correlative evaluation between flow velocity and response to stereotactic radiosurgery was also attempted. (author). 8 refs., 1 tab

  14. Health effect of exposure to internally deposited alpha-emitting radionuclides

    International Nuclear Information System (INIS)

    Iwata, Shiro

    1989-01-01

    The health effect of exposure on human population to internally deposited alpha-emitting radionuclides and their decay products has been considered as most hazardous radiation effect. However, the harmful late effects by the intake of radioactive nuclides are not definite in the epidemiological and clinical viewpoint. Only two cases, radium and thorium, have since long been noted for their deletrious effects to man. As the former, it has been first reported that dial workers in USA using 226 Ra can suffer from 'radiumjaw' which is a cancer of the bone of jaws. Another radium isotope, 224 Ra, was used for a medical reason as therapy against turberculosis of bone to German children during the years 1946∼1950, and has given rise to bone cancer. As the latter, Thorotrast (the commercial name of a colloidal thorium dioxide preparation), introduced for angiography in 1929 and utilized until about 1950, was found to cause malignant hepatic tumors, liver cirrhosis and blood diseases such as some kinds of leukemia and anemia. In Japan, the former cases have seldom found though, the latter cases are assumed over 1000. Especially, Thorotrast administered war-wounded ex-servicemen in World War II have been beyond 300 persons. The epidemiological and clinico-pathological studies have been demonstrated by the research Group on Biological Effect of Thorium in Special Project Research on Energy, Japan, as a fundamental study of the safe treatment of nuclear fuel materials. The resultant data of the study and risk evaluation of liver cancer for Japanese Thorotrast administered patients are reviewed related to that of another alpha-emitting radionuclides. (author)

  15. MR angiography of in situ and transplanted renal arteries

    International Nuclear Information System (INIS)

    Smith, H.J.; Bakke, S.J.

    1993-01-01

    Three-dimensional (3D) time-of-flight (TOF) MR angiography (MRA) was performed in 34 patients with suspected renal artery disease. In situ (i.e., nontransplanted) renal arteries were studied with MRA in 14 patients. Of these, 12 had conventional angiography for comparison. Twenty-four MRAs of transplanted renal arteries were obtained in 20 patients; 8 of these had angiography as well. Significant stenoses of in situ renal arteries were diagnosed with a sensitivity of 100% and a specificity of 95%. The stenoses were all proximal; 3D TOF MRA proved inadequate for depiction of peripheral renal arteries. MRA and angiography showed good agreement between findings in 7 of 8 patients with renal transplants. In one patient with a renal transplant, MRA showed a significant stenosis of the arterial anastomosis which appeared completely normal at i.a. DSA, indicating that findings at MRA still need to be confirmed by more established alternative methods. (orig.)

  16. CT angiography versus 3D rotational angiography in patients with subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Bechan, R.S.; Peluso, J.P.; Sluzewski, M.; Rooij, W.J. van [Sint Elisabeth Ziekenhuis Tilburg, Department of Radiology, Tilburg (Netherlands); Rooij, S.B. van [Medisch Centrum Alkmaar, Department of Radiology, Alkmaar (Netherlands); Sprengers, M.E.; Majoie, C.B. [Academisch Medisch Centrum, Department of Radiology, Amsterdam (Netherlands)

    2015-12-15

    CT angiography (CTA) is increasingly used as primary diagnostic tool to replace digital subtraction angiography (DSA) in patients with subarachnoid hemorrhage (SAH). However, 3D rotational angiography (3DRA) has substituted DSA as a reference standard. In this prospective observational study, we compare CTA with 3DRA of all cerebral vessels in a large cohort of patients with SAH. Of 179 consecutive patients with SAH admitted between March 2013 and July 2014, 139 underwent 64- to 256-detector row CTA followed by complete cerebral 3DRA within 24 h. In 86 patients (62 %), 3DRA was performed under general anesthesia. Two observers from outside hospitals reviewed CTA data. In 118 of 139 patients (85 %), 3DRA diagnosed the cause of hemorrhage: 113 ruptured aneurysms, three arterial dissections, one micro-arteriovenous malformation (AVM), and one reversible vasoconstriction syndrome. On CTA, both observers missed all five non-aneurysmal causes of SAH. Sensitivity of CTA in depicting ruptured aneurysms was 0.88-0.91, and accuracy was 0.88-0.92. Of 113 ruptured aneurysms, 28 were ≤3 mm (25 %) and of 95 additional aneurysms, 71 were ≤3 mm (75 %). Sensitivity of depicting aneurysms ≤3 mm was 0.28-0.43. Of 95 additional aneurysms, the two raters missed 65 (68 %) and 58 (61 %). Sensitivity in detection was lower in aneurysms of the internal carotid artery than in other locations. CTA had some limitations as primary diagnostic tool in patients with SAH. All non-aneurysmal causes for SAH and one in ten ruptured aneurysms were missed. Performance of CTA was poor in aneurysms ≤3 mm. The majority of additional aneurysms were not depicted on CTA. (orig.)

  17. 3D Deep Learning Angiography (3D-DLA) from C-arm Conebeam CT.

    Science.gov (United States)

    Montoya, J C; Li, Y; Strother, C; Chen, G-H

    2018-05-01

    Deep learning is a branch of artificial intelligence that has demonstrated unprecedented performance in many medical imaging applications. Our purpose was to develop a deep learning angiography method to generate 3D cerebral angiograms from a single contrast-enhanced C-arm conebeam CT acquisition in order to reduce image artifacts and radiation dose. A set of 105 3D rotational angiography examinations were randomly selected from an internal data base. All were acquired using a clinical system in conjunction with a standard injection protocol. More than 150 million labeled voxels from 35 subjects were used for training. A deep convolutional neural network was trained to classify each image voxel into 3 tissue types (vasculature, bone, and soft tissue). The trained deep learning angiography model was then applied for tissue classification into a validation cohort of 8 subjects and a final testing cohort of the remaining 62 subjects. The final vasculature tissue class was used to generate the 3D deep learning angiography images. To quantify the generalization error of the trained model, we calculated the accuracy, sensitivity, precision, and Dice similarity coefficients for vasculature classification in relevant anatomy. The 3D deep learning angiography and clinical 3D rotational angiography images were subjected to a qualitative assessment for the presence of intersweep motion artifacts. Vasculature classification accuracy and 95% CI in the testing dataset were 98.7% (98.3%-99.1%). No residual signal from osseous structures was observed for any 3D deep learning angiography testing cases except for small regions in the otic capsule and nasal cavity compared with 37% (23/62) of the 3D rotational angiographies. Deep learning angiography accurately recreated the vascular anatomy of the 3D rotational angiography reconstructions without a mask. Deep learning angiography reduced misregistration artifacts induced by intersweep motion, and it reduced radiation exposure

  18. Rapid line scan MR angiography

    International Nuclear Information System (INIS)

    Frahm, J.; Merboldt, K.D.; Hanicke, W.; Bruhn, H.

    1987-01-01

    Direct MR angiography may be performed using line scan imaging techniques combined with presaturation of stationary spins. Thus, a single line scan echo yields a projection of vessels due to the signal from reflowing unsaturated spins. Reconstruction of an angiographic image is performed line by line at slightly incremented positions. In particular, line scan angiography is direct and fast without a sensitivity to artifacts even for high flow rates. Image resolution and field of view may be chosen without restrictions, and zoom images using enhanced gradients may be recorded without aliasing artifacts. The method is robust with respect to eddy currents and pulsatile flow. Line scan MR angiograms of phantoms, animals, and human volunteers have been recorded using 90 0 radio frequency pulses and gradient-recalled echoes

  19. Pulmonary angiography with lopamidol 370

    International Nuclear Information System (INIS)

    Braun, S.D.; Saeed, M.; Perlmutt, L.M.; Newman, G.E.; Illescas, F.F.; Cohan, R.H.; Dunnick, N.R.

    1986-01-01

    Fifty-one consecutive patients who underwent pulmonary angiography with iopamidol, 370 mg/ml, were studied prospectively. Patients were asked to grade any heat or pain felt on injection, and were observed for coughing. Right atrial and pulmonary artery pressures were obtained before the first and after the final contrast agent injection. Pressure changes were compared with those in a consecutive group of 25 patients who underwent examinations performed with Na-meglumine diatrizoate, 370 mg/ml. Film quality was evaluated for patient motion. Iopamidol generated marked discomfort in only three patients. Pressure changes were largely unremarkable. In no case was there any significant motion artifact secondary to coughing. Iopamidol is a safe, well-tolerated contrast agent for pulmonary angiography. It improves image quality by nearly eliminating coughing

  20. Real-time radionuclide cineangiography in the noninvasive evaluation of global and regional left ventricular function at rest and during exercise in patients with coronary-artery disease

    International Nuclear Information System (INIS)

    Borer, J.S.; Bacharach, S.L.; Green, M.V.; Kent, K.M.; Epstein, S.E.; Johnston, G.S.

    1977-01-01

    Although coronary angiography defines regions of potential ischemia in patients with coronary-artery disease, accurate assessment of the presence and functional importance of ischemia requires appraisal of regional and global left ventricular function during stress. To perform such assessment, we developed a noninvasive real-time radionuclide cineangiographic procedure permitting continuous monitoring and analysis of left ventricular function during exercise. In 11 patients with coronary disease who had normal regional and global ventricular function at rest, new regions of dysfunction developed during exercise (P less than 0.001), and in 10, global ejection fraction dropped 7 to 47 percent. Fourteen age-matched normal subjects were studied; during exercise none had regional dysfunction, and each increased global ejection fraction (average increase, 23 +- 3 percent [+-S.E.], P less than 0.001 as compared with patients with coronary disease). Radionuclide cineangiography during exercise permits accurate assessment of the presence and functional severity of ischemic heart disease

  1. Modelling the behaviour of uranium-series radionuclides in soils and plants taking into account seasonal variations in soil hydrology

    International Nuclear Information System (INIS)

    Pérez-Sánchez, D.; Thorne, M.C.

    2014-01-01

    In a previous paper, a mathematical model for the behaviour of 79 Se in soils and plants was described. Subsequently, a review has been published relating to the behaviour of 238 U-series radionuclides in soils and plants. Here, we bring together those two strands of work to describe a new mathematical model of the behaviour of 238 U-series radionuclides entering soils in solution and their uptake by plants. Initial studies with the model that are reported here demonstrate that it is a powerful tool for exploring the behaviour of this decay chain or subcomponents of it in soil-plant systems under different hydrological regimes. In particular, it permits studies of the degree to which secular equilibrium assumptions are appropriate when modelling this decay chain. Further studies will be undertaken and reported separately examining sensitivities of model results to input parameter values and also applying the model to sites contaminated with 238 U-series radionuclides. - Highlights: • Kinetic model of radionuclide transport in soils and uptake by plants. • Takes soil hydrology and redox conditions into account. • Applicable to the whole U-238 chain, including Rn-222, Pb-210 and Po-210. • Demonstrates intra-season and inter-season variability on timescales up to thousands of years

  2. Combined use of intraarterial digital subtraction angiography with conventional retrograde brachial vertebral angiography

    International Nuclear Information System (INIS)

    Yamaguchi, Tatsuo; Ogawa, Toshihide; Inugami, Atsushi; Kawata, Yasushi; Shishido, Fumio; Uemura, Kazuo

    1985-01-01

    For 102 patients who had the examination of conventional bilaterally retrograde brachial vertebral angiography (retrograde VAG), intraarterial digital subtraction angiography (DSA) was successively performed to investigate steno-occlusive lesions of proximal vertebral and subclavian arteries. All the patients had no complication due to the DSA procedure. In 50% of 72 ischemic stroke cases, positive findings were found either in the origin of the vertebral artery or in the subclavian artery. Stenosis of more than 50% of the lumen of the vertebral artery were found in 14% of the cases at the origin of the right one and also in 14% in the left one. Occlusion of the vertebral artery was found in 4% in the left side only. In 30 cases with non-ischemic brain diseases, positive findings were noted in 10%. Intraarterial DSA combined with retrograde VAG was thought to be useful, especially in the examination for ischemic stroke. (author)

  3. Radionuclides in diffusion probing of inorganic materials based on chalcogenides

    International Nuclear Information System (INIS)

    Firsova, L.P.

    1994-01-01

    Migration of tellurium-125m, selenium-75, sulfur-35 radionuclides in solid solutions Pb 1-y (Se 0.08 Te 0.92 ) y and (Pb 1-x Sn x ) y Te 1-y , where x=0.1 and 0.2, has been studied, the results are presented. Data on dependence of selenium and tellurium self-diffusion coefficients on temperature in the range of 600-750 deg C are given. The results of the study of self-diffusion coefficient isothermal dependences on lead and tellurium vapour pressure in equilibrium with solid phases have been considered. It is ascertained that a change in the temperature and p-n transitions initiate the change in self-diffusion mechanisms of chalcogenide atoms. 8 refs., 3 tabs

  4. Radionuclide transfer from mother to embryo

    International Nuclear Information System (INIS)

    Toader, M.; Vasilache, R.A.; Scridon, R.; Toader, M.L.

    1998-01-01

    The transfer of radionuclides from mother to embryo is still a matter of high interest. Therefore, the relation was investigated between the amount of radionuclides in the embryo and the dietary intake of the mother, this for two scenarios: a recurrent intake of variable amounts of radionuclides, and a long-term intake of a relatively constant amount of radionuclides, the radionuclide being 137 Cs. In the first case, the amount of radionuclides present in the embryo increases with the age of the embryo and with the intake of the mother. In the second case, no correlation could be found between the age of the embryo and its radioactive content; only the correlation between the intake of the mother and the radionuclide content of the embryo remained. (A.K.)

  5. Magnetic resonance angiography of fetal vasculature at 3.0 T

    Science.gov (United States)

    Krishnamurthy, Uday; Jella, Pavan K.; Mody, Swati S.; Yadav, Brijesh K.; Hendershot, Kelly; Hernandez-Andrade, Edgar; Yeo, Lami; Cabrera, Maria D.; Haacke, Ewart M.; Hassan, Sonia S.; Romero, Roberto

    2016-01-01

    Magnetic resonance angiography has not been used much previously for visualizing fetal vessels in utero for reasons that include a contraindication for the use of exogenous contrast agents, maternal respiratory motion and fetal motion. In this work, we report the feasibility of using an appropriately modified clinical time-of-flight magnetic resonance imaging sequence for non-contrast angiography of human fetal and placental vessels at 3.0 T. Using this 2D angiography technique, it is possible to visualize fetal vascular networks in late pregnancy. PMID:27189488

  6. Magnetic resonance angiography of fetal vasculature at 3.0 T

    International Nuclear Information System (INIS)

    Neelavalli, Jaladhar; Krishnamurthy, Uday; Yadav, Brijesh K.; Haacke, Ewart M.; Jella, Pavan K.; Hendershot, Kelly; Cabrera, Maria D.; Mody, Swati S.; Hernandez-Andrade, Edgar; Yeo, Lami; Hassan, Sonia S.; Romero, Roberto

    2016-01-01

    Magnetic resonance angiography has not been used much previously for visualizing fetal vessels in utero for reasons that include a contraindication for the use of exogenous contrast agents, maternal respiratory motion and fetal motion. In this work, we report the feasibility of using an appropriately modified clinical time-of-flight magnetic resonance imaging sequence for non-contrast angiography of human fetal and placental vessels at 3.0 T. Using this 2D angiography technique, it is possible to visualize fetal vascular networks in late pregnancy. (orig.)

  7. Magnetic resonance angiography of fetal vasculature at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Neelavalli, Jaladhar; Krishnamurthy, Uday; Yadav, Brijesh K.; Haacke, Ewart M. [Wayne State University School of Medicine, Department of Radiology, Detroit, MI (United States); Wayne State University, Department of Biomedical Engineering, Detroit, MI (United States); Jella, Pavan K.; Hendershot, Kelly; Cabrera, Maria D. [Wayne State University School of Medicine, Department of Radiology, Detroit, MI (United States); Mody, Swati S. [Wayne State University School of Medicine, Department of Radiology, Detroit, MI (United States); Children' s Hospital of Michigan, Department of Radiology, Detroit, MI (United States); Hernandez-Andrade, Edgar; Yeo, Lami; Hassan, Sonia S. [Wayne State University, Department of Obstetrics and Gynecology, Detroit, MI (United States); Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD, and Detroit, MI (United States); Romero, Roberto [Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD, and Detroit, MI (United States); University of Michigan, Department of Obstetrics and Gynecology, Ann Arbor, MI (United States); Michigan State University, Department of Epidemiology and Biostatistics, East Lansing, MI (United States); Wayne State University, Center for Molecular Medicine and Genetics, Detroit, MI (United States)

    2016-12-15

    Magnetic resonance angiography has not been used much previously for visualizing fetal vessels in utero for reasons that include a contraindication for the use of exogenous contrast agents, maternal respiratory motion and fetal motion. In this work, we report the feasibility of using an appropriately modified clinical time-of-flight magnetic resonance imaging sequence for non-contrast angiography of human fetal and placental vessels at 3.0 T. Using this 2D angiography technique, it is possible to visualize fetal vascular networks in late pregnancy. (orig.)

  8. Radionuclide diagnosis of emergency states

    International Nuclear Information System (INIS)

    Ishmukhametov, A.I.

    1985-01-01

    Solution of emergency state radionuclide diagnostics from the technical point of view is provided by the application of the mobile quick-operating equipment in combination with computers, by the use of radionuclides with acceptable for emergency medicine characteristics and by development of radionuclide investigation data propcessing express-method. Medical developments include the study of acute disease and injury radioisotope semiotics, different indication diagnostic value determining, comparison of the results, obtained during radionuclide investigation, with clinicolaboratory and instrumental data, separation of methodical complex series

  9. Three dimensional CT angiography (3D-CTA) in ruptured aneurysm surgery on acute stage

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Endo, Yuji; Nakano, Masayuki

    1998-01-01

    We evaluated three-dimensional CT angiography (3D-CTA) for the treatment of acutely ruptured cerebral aneurysms. Sixty patients with subarachnoid hemorrhage from cerebral aneurysms were investigated both by 3D-CTA and conventional angiography and 26 patients were studied using 3D-CTA without conventional angiography. In the 60 cases, both 3D-CTA and the conventional angiography revealed 100% accuracy in diagnosing ruptured aneurysms, and 3D-CTA and the conventional angiography showed 96% and 92% accuracy for unruptured aneurysms respectively. 3D-CTA was equal or superior to the conventional angiography. Based on these data, since December, 1996, we have operated on 26 consecutive patients with ruptured aneurysms located in the anterior circulation of the circle of Willis, using 3D-CTA without conventional angiography. Thirty-one aneurysms, including 5 associated unruptured aneurysms, were visualized by 3D-CTA and verified at surgery. All aneurysms were clipped successfully. We think that it will be possible to operate on most ruptured aneurysms using only 3D-CTA without the conventional angiography except for the cases of the following situations: if a cerebral infarction is present, conventional angiography is required to evaluate for a stenotic or occlusive lesion of the intracranial arteries, cervical carotid, or vertebral arteries; in cases of giant or large aneurysms, the dynamic information provided by the conventional angiography is needed in case bypass surgery is necessary; and for aneurysms close to bony structures, such as an internal carotid-ophthalmic artery aneurysm, conventional angiography is necessary. (author)

  10. Magnetic resonance angiography of arteriovenous malformation in the thalamus

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Hirofumi; Kida, Yoshihisa; Kobayashi, Tatsuya; Tanaka, Takayuki; Iwakoshi, Takayasu; Kai, Osamu; Hirose, Mitsuhiko [Komaki City Hospital, Aichi (Japan)

    1993-11-01

    A comparative study of magnetic resonance angiography and conventional angiography of arteriovenous malformation in the thalamus showed that both methods clearly visualized the feeding arteries: perforating branches of the posterior cerebral artery, posterior choroidal artery and lenticulostriate artery. Draining veins such as the internal cerebral vein were also demonstrated well. (author).

  11. The evaluation of a formalized queue management system for coronary angiography waiting lists.

    Science.gov (United States)

    Alter, D A; Newman, Alice M; Cohen, Eric A; Sykora, Kathy; Tu, Jack V

    2005-11-01

    Lengthy waiting lists for coronary angiography have been described in many health care systems worldwide. The extent to which formal queue management systems may improve the prioritization and survival of patients in the angiography queue is unknown. To prospectively evaluate the performance of a formal queue management system for patients awaiting coronary angiography in Ontario. The coronary angiography urgency scale, a formal queue management system developed in 1993 using a modified Delphi panel, allocates recommended maximum waiting times (RMWTs) in accordance with clinical necessity. By using a provincial clinical registry, 35,617 consecutive patients referred into the coronary angiography queue between April 1, 2001, and March 31, 2002, were prospectively tracked. Cox proportional hazards models were used to examined mortality risk across urgency after adjusting for additional clinical and comorbid factors. Good agreement was determined in urgency ratings between scores from the coronary angiography urgency scale and implicit physician judgement, which was obtained independently at the time of the index referral (weighted kappa = 0.49). The overall mortality in the queue was 0.3% (0.47%, 0.26% and 0.13% for urgent, semiurgent and elective patients, respectively). Urgency, as specified by the coronary angiography urgency scale, was the strongest predictor of death in the queue (Pqueue management system may decrease mortality in the coronary angiography queue. The authors recommend its implementation in health care systems where patients experience excessive waiting time delays for coronary angiography.

  12. Anthropogenic radionuclides in the environment

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Q; Weng, J; Wang, J

    2007-11-15

    Studies of radionuclides in the environment have entered a new era with the renaissance of nuclear energy and associated fuel reprocessing, geological disposal of high-level nuclear wastes, and concerns about national security with respect to nuclear non-proliferation. This work presents an overview of anthropogenic radionuclide contamination in the environment, as well as the salient geochemical behavior of important radionuclides. We first discuss the following major anthropogenic sources and current development that contribute to the radionuclide contamination of the environment: (1) nuclear weapons program; (2) nuclear weapons testing; (3) nuclear power plants; (4) commercial fuel reprocessing; (5) geological repository of high-level nuclear wastes, and (6) nuclear accidents. Then, we summarize the geochemical behavior for radionuclides {sup 99}Tc, {sup 129}I, and {sup 237}Np, because of their complex geochemical behavior, long half-lives, and presumably high mobility in the environment. Biogeochemical cycling and environment risk assessment must take into account speciation of these redox-sensitive radionuclides.

  13. Radionuclide daughter inventory generator code: DIG

    International Nuclear Information System (INIS)

    Fields, D.E.; Sharp, R.D.

    1985-09-01

    The Daughter Inventory Generator (DIG) code accepts a tabulation of radionuclide initially present in a waste stream, specified as amounts present either by mass or by activity, and produces a tabulation of radionuclides present after a user-specified elapsed time. This resultant radionuclide inventory characterizes wastes that have undergone daughter ingrowth during subsequent processes, such as leaching and transport, and includes daughter radionuclides that should be considered in these subsequent processes or for inclusion in a pollutant source term. Output of the DIG code also summarizes radionuclide decay constants. The DIG code was developed specifically to assist the user of the PRESTO-II methodology and code in preparing data sets and accounting for possible daughter ingrowth in wastes buried in shallow-land disposal areas. The DIG code is also useful in preparing data sets for the PRESTO-EPA code. Daughter ingrowth in buried radionuclides and in radionuclides that have been leached from the wastes and are undergoing hydrologic transport are considered, and the quantities of daughter radionuclide are calculated. Radionuclide decay constants generated by DIG and included in the DIG output are required in the PRESTO-II code input data set. The DIG accesses some subroutines written for use with the CRRIS system and accesses files containing radionuclide data compiled by D.C. Kocher. 11 refs

  14. MR angiography of the TMJ in asymptomatic volunteers

    International Nuclear Information System (INIS)

    Takagi, Ritsuo; Ohashi, Yasushi; Westesson, P.L.; Togashi, Hirosuke

    1998-01-01

    To evaluate the vascular anatomy of the temporomandibular joint (TMJ) and surrounding soft tissue non-invasively, we applied magnetic resonance (MR) angiography for delineating the arterial architecture around the TMJ. MR angiograms of the left and right TMJs in asymptomatic volunteers were obtained using 3D/Time-of-flight (TOF) (First Field Echo, TR/TE/FLIP=46 ms/6.8 ms/17 deg) with intravenous contrast. These MR angiograms were compared with experimental angiograms of human TMJ autopsy specimens in order to identify each of the branches of the arteries on the MR angiograms. This study enabled the depiction by MR angiography of arterial vessels around the TMJ region to some degree. In conclusion, MR angiography appears promising as a non-invasive tool to evaluate the vascular anatomy of the TMJ. (author)

  15. Contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Bosmans, H.; Marchal, G.

    1996-01-01

    Despite many optimizations, the current limitations of plain MR angiography include: Saturation that impairs the visualization of veins and arteries with slow flow and spin-dephasing signal voids in locations with turbulent flow. Recently, the use of contrast agents has been proposed to cope with these remaining problems. Because of induced shortening of the T1 of the blood, saturation in the blood vessels is overcome. As a result, arteries and veins are visualized with the same signal intensity, which makes the technique less flow-dependent. In combination with short T1-weighted acquisitions, today CE MRA can be obtained while the patient is holding his breath. This last approach is most promising for abdominal applications since the respiratory motion can be frozen. As these acquisitions also use very short echo times, spin dephasing can be reduced. In conclusion, the use of contrast agents has greatly increased the clinical usefulness of MR angiography. (orig.) [de

  16. Critical review: Radionuclide transport, sediment transport, and water quality mathematical modeling; and radionuclide adsorption/desorption mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Y.; Serne, R.J.; Arnold, E.M.; Cowan, C.E.; Thompson, F.L. [Pacific Northwest Lab., Richland, WA (United States)

    1981-01-01

    This report describes the results of a detailed literature review of radionuclide transport models applicable to rivers, estuaries, coastal waters, the Great Lakes, and impoundments. Some representatives sediment transport and water quality models were also reviewed to evaluate if they can be readily adapted to radionuclide transport modeling. The review showed that most available transport models were developed for dissolved radionuclide in rivers. These models include the mechanisms of advection, dispersion, and radionuclide decay. Since the models do not include sediment and radionuclide interactions, they are best suited for simulating short-term radionuclide migration where: (1) radionuclides have small distribution coefficients; (2) sediment concentrations in receiving water bodies are very low. Only 5 of the reviewed models include full sediment and radionuclide interactions: CHMSED developed by Fields; FETRA SERATRA, and TODAM developed by Onishi et al, and a model developed by Shull and Gloyna. The 5 models are applicable to cases where: (1) the distribution coefficient is large; (2) sediment concentrations are high; or (3) long-term migration and accumulation are under consideration. The report also discusses radionuclide absorption/desorption distribution ratios and addresses adsorption/desorption mechanisms and their controlling processes for 25 elements under surface water conditions. These elements are: Am, Sb, C, Ce, Cm, Co, Cr, Cs, Eu, I, Fe, Mn, Np, P, Pu, Pm, Ra, Ru, Sr, Tc, Th, {sup 3}H, U, Zn and Zr.

  17. Equilibrium and non-equilibrium phenomena in arcs and torches

    NARCIS (Netherlands)

    Mullen, van der J.J.A.M.

    2000-01-01

    A general treatment of non-equilibrium plasma aspects is obtained by relating transport fluxes to equilibrium restoring processes in so-called disturbed Bilateral Relations. The (non) equilibrium stage of a small microwave induced plasma serves as case study.

  18. Gallbladder visualization on CT shortly after angiography with ioxaglate

    International Nuclear Information System (INIS)

    Tajima, H.; Kaizu, T.; Ichikawa, T.; Kumazaki, T.

    1994-01-01

    Thirty-five patients underwent CT examination 15 to 30 min after abdominal angiography with ioxaglate. The gallbladder was visualized in 12 patients in the absence of clinical evidence of renal impairment. Gallbladder opacification on CT examinations shortly after angiography shows that the hepatobiliary tract is important in the excretion of ioxaglate. (orig.)

  19. Comparison of magnetic resonance angiography and conventional angiography in sickle cell disease: clinical significance and realibility

    International Nuclear Information System (INIS)

    Kandeel, A.Y.; Zimmerman, R.A.; Ohene-Frempong, K.

    1996-01-01

    We retrospectively reviewed the medical records and conventional angiograms of 21 patients with known sickle cell disease, who underwent a total of 50 magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) studies. MRA and conventional angiography were assessed separately for evidence of stenosis or occulusion. Follow up MRI/MRA studies were also assessed for evidence of progression, regression or stability of the disease in these patients. In the carotid circulation, MRA made the correct diagnosis in 85% of the vessels evaluated with a sensitivity of 80.5% and a specificity of 94%. MRA was also found to show evidence of disease progression, more often than did MRI or the clinical condition of the patients. (orig.)

  20. Diagnostic value of multislice computed tomography angiography in coronary artery disease: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Jiang Wen

    2006-01-01

    Purpose: To perform a meta-analysis of the diagnostic value of multislice CT (MSCT) angiography in the detection of coronary artery disease (CAD) when compared to conventional coronary angiography. Materials and methods: A search of PubMed and MEDLINE databases for English literature was performed. Only studies with at least 10 patients comparing MSCT angiography with conventional coronary angiography in the detection of CAD were included. Diagnostic value of MSCT angiography compared to coronary angiography was compared and analyzed at segment-, vessel- and patient-based assessment. Results: 47 studies (67 comparisons) met the criteria and were included in our study. Pooled overall sensitivity, specificity and 95% confidence interval for MSCT angiography in the detection of CAD were 83% (79%, 89%), 93% (91%, 96%) at segment-based analysis; 90% (87%, 94%), 87% (80%, 93%) at vessel-based analysis; and 91% (88%, 95%), 86% (81%, 92%) at patient-based analysis, respectively. Diagnostic accuracy of MSCT angiography in evaluating assessable segments was significantly improved with 64-slice scanners when compared to that with 4- and 16-slice scanners (p < 0.05). Conclusion: Our meta-analysis showed that MSCT angiography has potential diagnostic accuracy in the detection of CAD. Diagnostic performance of MSCT angiography has been significantly improved with the latest 64-slice CT, with resultant high qualitative and quantitative diagnostic accuracy. 16-slice CT was limited in spatial resolution which makes it difficult to perform quantitative assessment of coronary artery stenoses

  1. Influence of nifedipine on left ventricular perfusion and function in patients with unstable angina: Evaluation with radionuclide techniques

    Energy Technology Data Exchange (ETDEWEB)

    Wall, E.E. van der; Kerkkamp, H.J.; Simoons, M.L.; Rijk, P.P. van; Reiber, J.H.C.; Bom, N.; Lubsen, J.C.; Lie, K.I.

    1986-04-01

    In 1981, a large, double-blind, randomized trial was started in The Netherlands to evaluate the therapeutic effects of nifedipine and/or metoprolol in patients with unstable angina. This study has been called the Holland Interuniversity Nifedipine/metoprolol Trial (HINT) and required several hundred patients to establish potential therapeutic effects. From December 1982 to January 1984 the effects of nifedipine on left ventricular (LV) performance in a subgroup of 52 HINT patients were studied using radionuclide techniques. All patients (23 on nifedipine, 29 controls) underwent thallium-201 scintigraphy or radionuclide angiography just before and 48 h after the start of experimental medication. The radionuclide angiographic studies were also performed at 1 and 4 h after treatment. Nifedipine did not influence the incidence of disapperance of perfusion defects on the 48-h thallium images. No significant differences in overall LV ejections fraction (EF) were seen at any time between nifedipine-treated patients and controls. However, paired observations in 37 patients showed improvement of LVEF after 48 h in 8 patients on nifedipine and in only 1 control patient. Scintigraphic measurements on admission were not related to clinical outcome after 48 h. Concomitant administration of metoprolol did not influence LVEF in either group. It is concluded that nifedipine improves LVEF after 48 h in a subset of patients with unstable angina without affecting myocardial perfusion. This finding indicates that nifedipine has a predominant effect on afterload reduction in patients with unstable angina. Also, early scintigraphic measurements had no significant predictive value for subsequent cardiac events.

  2. Correlation between coronary computed tomographic angiography and fractional flow reserve

    DEFF Research Database (Denmark)

    Kristensen, Thomas Skaarup; Engstrøm, Thomas; Kelbæk, Henning

    2010-01-01

    Coronary CT angiography (CCTA) has become an important modality to evaluate the presence of coronary artery disease. Coronary artery stenosis of intermediate severity remains a therapeutic dilemma. Measurement of fractional flow reserve (FFR) during coronary angiography is the most established...

  3. First experience of combined cardiac PET/64-detector CT angiography with invasive angiographic validation

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Endozo, Raymondo; Menezes, Leon J.; Prvulovich, Elizabeth; Ell, Peter J.; Speechly-Dick, Marie-Elsya; McEwan, Jean; Pugliese, Francesca; Habib, Said B.

    2009-01-01

    Despite modern CT systems and expert evaluators, the diagnostic performance of coronary CT angiography is limited by overestimation of vessel stenosis which reduces the positive predictive value (PPV) of the test. The aim of this study was to evaluate the performance of combined cardiac PET/64-detector CT angiography. Included in this retrospective study were 33 consecutive patients (5 women, 28 men; mean age 61.6 years, range 47-87 years, mean BMI 27.3±5.2 kg/m 2 ) with clinically suspected flow-limiting coronary artery disease who underwent combined cardiac PET/64-detector CT angiography and invasive angiography. Combined PET/CT images were reported by an experienced dual-accredited radiologist/nuclear physician. An experienced cardiac CT radiologist re-read the CT images without PET. Stenotic disease was defined as >50% vessel narrowing. Invasive coronary angiography was used as a reference standard. Local ethics committee approval and patient consent were obtained. CT angiography (without PET data) was concordant with invasive angiography in 31/33 patients and at a patient level, the sensitivity in detecting significant coronary artery lesions was 100%, the specificity was 82%, the PPV was 92% and the negative predictive value (NPV) was 100%. Using combined PET/CT angiography the findings were concordant with invasive angiography in 32/33 patients and at a patient level, the sensitivity was 96%, the specificity was 100%, the PPV was 100% and the NPV was 91%. The use of integrated cardiac PET/64-detector CT angiography is feasible and appears to improve some aspects of the diagnostic performance of 64-detector coronary artery angiography in detecting coronary artery disease. (orig.)

  4. Radionuclide angiographical assessment of the effects of aorto-coronary bypass grafting on ventricular function during rest and exercise

    International Nuclear Information System (INIS)

    Kito, Yoshitsugu; Fujita, Tsuyoshi; Ohara, Kuniyoshi

    1983-01-01

    Ventricular function was measured by radionuclide angiography during rest and exercise in 27 patients before and after aorto-coronary bypass grafting (AC bypass). The patients were divided in three groups: 6 patients in complete revascularisation (group A), 8 patients in surgical complete revascularisation (group B), and 13 patients in incomplete revascularisation (group C). Heart rate increased by exercise from 58 +- 5 bpm to 87 +- 5 bpm, from 60 +- 5 bpm to 90 +- 15 bpm, and from 61 +- 8 bpm to 84 +- 7 bpm before AC bypass, and increased from 81 +- 7 bpm to 116 +- 11 bpm, from 86 +- 13 bpm to 114 +- 12 bpm, and from 80 +- 11 bpm to 106 +- 13 bpm after AC bypass in group A, B and C, respecitively. EF decreased by exercise from 61 +- 7 % to 58 +- 12 %, from 53 +- 10 % to 49 +- 7 %, and from 54 +- 8 % to 52 +- 8 % before AC bypass, and increased by exercise from 66 +- 7 % to 77 +- 6 %, from 49 +- 11 % to 56 +- 13 %, and from 54 +- 8 % to 59 +- 10 % after AC bypass in group A,FB and C, respectively. dV/dt(Vmax/sec) increased by exercise from 4.0 +- 1.0 to 4.4 +- 1.0, from 2.5 +- 1.0 to 3.4 +- 1.5 and from 3.5 +- 0.5 to 3.4 +- 0.6 before AC bypass, and increased from 3.9 +- 0.5 to 6.2 +- 0.7, from 3.5 +- 0.9 to 5.0 +- 0.7, and from 3.6 +- 1.0 to 5.4 +- 1.5 after AC bypass in group A,B and C, respectively. In conclusion, left ventricular performance during exercise was significantly increased after AC bypass in all patients. However, the rate of increase in left ventricular performance during exercise after AC bypass was more significant in the group of complete revascularisation than in the group of others. Serial application of radionuclide angiography to patients after AC bypass appears promising in evaluating the long-term effects of operation on ventricular function. (author)

  5. History of medical radionuclide production.

    Science.gov (United States)

    Ice, R D

    1995-11-01

    Radionuclide production for medical use originally was incidental to isotope discoveries by physicists and chemists. Once the available radionuclides were identified they were evaluated for potential medical use. Hevesy first used 32P in 1935 to study phosphorous metabolism in rats. Since that time, the development of cyclotrons, linear accelerators, and nuclear reactors have produced hundreds of radionuclides for potential medical use. The history of medical radionuclide production represents an evolutionary, interdisciplinary development of applied nuclear technology. Today the technology is represented by a mature industry and provides medical benefits to millions of patients annually.

  6. The diffusion and deposition of the gaseous and solid alpha radionuclides/aerosols in air

    International Nuclear Information System (INIS)

    Danis, A.; Ciubotariu, M.; Oncescu, M.; Mocsy, I.

    1999-01-01

    The diffusion and deposition of gaseous and solids alpha radionuclides and aerosols in air are processes which implicate low element amounts and therefore their studies require the using of very accurate and sensitive analysis methods. The alpha track method meets these requirements. The used alpha radionuclides were: Rn-222, as gaseous radionuclide and its solid descendants genetically related as solid radionuclides and the descendants attached to different particles from air as alpha aerosols. All these radionuclides were obtained from a calibrated Ra-226 source. The source was included into an air tight device with a well known volume and used after 40 days when the Ra-226 and its alpha descendants were under radioactive equilibrium. The relative amount and activity of each decay product, at any duration, for any initial mass of Ra-226 parent radionuclide, were calculated using a programme for computation of the U-238 radioactive series gamma accumulation, UURASE, adapted for alpha accumulation as ALFAURASE programme. The radon, Rn-222, as well as the solid alpha radionuclides and aerosols were measured using a new alpha monitoring device with or without paper filter for solid radionuclides and aerosols stopping. The track detectors of CR-39 type were incorporated with these monitoring devices. In order to calibrate the CR-39 detectors, a radon intercomparison programme was established with the participation of the SSNTD group from the Institute of Nuclear Research ATOMKI, Debrecen, Hungary, Institute of Public Health, Cluj-Napoca and SSNTD research group from IFIN-HH. We have used for radon calibration a special experimental device and a Ra-226 source. Using an air tight diffusion and deposition device, coupled with the source device, the concentration of radon and solid alpha radionuclides and aerosols were determined using the alpha track method. The alpha monitoring devices were fixed vertically at different distances from the place of radon penetration into

  7. Spontaneous rectus sheath hematoma: The utility of CT angiography

    Directory of Open Access Journals (Sweden)

    Antonio Pierro, MD

    2018-04-01

    Full Text Available We described the utility of computed tomography (CT angiography in detection of bleeding vessels for a rapid percutaneous arterial embolization of the spontaneous rectus sheath hematoma. A 70-year-old woman comes to our attention with acute abdominal pain and a low hemoglobin level. An unenhanced CT was performed demonstrating a large rectus sheath hematoma. A conservative management was initially established. Despite this therapy, the abdominal pain increased together with a further decrease of hemoglobin values. A CT angiography was then performed, demonstrating an active bleeding within the hematoma and addressing the patient to a rapid percutaneous arterial embolization. Keywords: Rectus sheath hematoma, Acute abdomen, Arterial embolization, CT angiography, Active bleeding

  8. Nosocomial septicemia and therapeutic angiography. Report of four cases

    International Nuclear Information System (INIS)

    Meyer, Ph.; Reizine, D.; Merland, J.J.; Guerin, J.M.

    1988-01-01

    Therapeutic angiography may be responsible for rare, but serious infectious complications.The authors report 4 cases occurring immediately following angiography. Three modes of contamination are proposed. Contamination by material used during the angiography is due to multiresistant hospital organisms. Penetration of cutaneous organisms into the circulation from the puncture site and bacterial contamination of a focus of tissue necrosis distal to the embolisation explain the other cases. Curative treatment is difficult because of the possibility of contamination of the embolisation material. Prophylactic treatment is essential and consists of respect of the rules of surgical asepsis, bacteriological control of the fluids used and eradication of adjacent septic foci. Routine antibiotic prophylaxis has yet to be evaluated [fr

  9. Models for transport and fate of carbon, nutrients and radionuclides in the aquatic ecosystem at Oeregrundsgrepen

    Energy Technology Data Exchange (ETDEWEB)

    Erichsen, Anders Christian; Moehlenberg, Flemming; Closter, Rikke Margrethe; Sandberg, Johannes [DHI, Hoersholm (Denmark)

    2010-06-15

    -stationary equilibrium within the model area. The coupled ecosystem and radionuclide models were used to simulate present conditions, i.e. 2020 AD. Six radionuclides were modelled explicitly in addition to C-14. They represent a wide range of accumulation potentials and partition coefficients (K{sub d}, distribution of radionuclides between water, sediment and biota). The ecosystem and associated radionuclide model include a detailed sediment module where radionuclides can be bound by adsorption to the organic and inorganic fractions, be precipitated, be transported by resuspension and later deposited at larger depths. With the exception of radionuclides with very low particle affinity, such as Cl-35, the majority of radionuclides released in basins where they were introduced via groundwater flow remained in the sediments even after a simulation period of eight years. The spread of radionuclides with high partition coefficients for sediments from areas with groundwater flow takes place by sediment resuspension and subsequent transport and sedimentation. In the case of radionuclides with lower partition coefficients, release from the sediments to the water column followed by transport of dissolved radionuclides by currents plays a larger role. A significant result of the modelling was the quantification of the seasonal and spatial variation in radionuclide accumulation and in bioconcentration factors (BCFs) with spatial variation of BCFs often ranging 2 to 3 orders of magnitude. This variation was dominated by spatial differences in concentrations of radionuclides in water. In basins where radionuclides were introduced by groundwater flow, BCFs were typically 2-3 orders of magnitude lower than in deep basins without radionuclide release in the groundwater. In phytoplankton and grazers, bioconcentration factors (BCFs) scaled linearly to partition coefficients (Kd), underlining the fact that adsorption is an important process for radionuclide accumulation in the lower parts of the food web

  10. Models for transport and fate of carbon, nutrients and radionuclides in the aquatic ecosystem at Oeregrundsgrepen

    Energy Technology Data Exchange (ETDEWEB)

    Erichsen, Anders Christian; Moehlenberg, Flemming; Closter, Rikke Margrethe; Sandberg, Johannes (DHI, Hoersholm (Denmark))

    2010-06-15

    quasi-stationary equilibrium within the model area. The coupled ecosystem and radionuclide models were used to simulate present conditions, i.e. 2020 AD. Six radionuclides were modelled explicitly in addition to C-14. They represent a wide range of accumulation potentials and partition coefficients (K{sub d}, distribution of radionuclides between water, sediment and biota). The ecosystem and associated radionuclide model include a detailed sediment module where radionuclides can be bound by adsorption to the organic and inorganic fractions, be precipitated, be transported by resuspension and later deposited at larger depths. With the exception of radionuclides with very low particle affinity, such as Cl-35, the majority of radionuclides released in basins where they were introduced via groundwater flow remained in the sediments even after a simulation period of eight years. The spread of radionuclides with high partition coefficients for sediments from areas with groundwater flow takes place by sediment resuspension and subsequent transport and sedimentation. In the case of radionuclides with lower partition coefficients, release from the sediments to the water column followed by transport of dissolved radionuclides by currents plays a larger role. A significant result of the modelling was the quantification of the seasonal and spatial variation in radionuclide accumulation and in bioconcentration factors (BCFs) with spatial variation of BCFs often ranging 2 to 3 orders of magnitude. This variation was dominated by spatial differences in concentrations of radionuclides in water. In basins where radionuclides were introduced by groundwater flow, BCFs were typically 2-3 orders of magnitude lower than in deep basins without radionuclide release in the groundwater. In phytoplankton and grazers, bioconcentration factors (BCFs) scaled linearly to partition coefficients (Kd), underlining the fact that adsorption is an important process for radionuclide accumulation in the

  11. Models for transport and fate of carbon, nutrients and radionuclides in the aquatic ecosystem at Oeregrundsgrepen

    International Nuclear Information System (INIS)

    Erichsen, Anders Christian; Moehlenberg, Flemming; Closter, Rikke Margrethe; Sandberg, Johannes

    2010-06-01

    -stationary equilibrium within the model area. The coupled ecosystem and radionuclide models were used to simulate present conditions, i.e. 2020 AD. Six radionuclides were modelled explicitly in addition to C-14. They represent a wide range of accumulation potentials and partition coefficients (K d , distribution of radionuclides between water, sediment and biota). The ecosystem and associated radionuclide model include a detailed sediment module where radionuclides can be bound by adsorption to the organic and inorganic fractions, be precipitated, be transported by resuspension and later deposited at larger depths. With the exception of radionuclides with very low particle affinity, such as Cl-35, the majority of radionuclides released in basins where they were introduced via groundwater flow remained in the sediments even after a simulation period of eight years. The spread of radionuclides with high partition coefficients for sediments from areas with groundwater flow takes place by sediment resuspension and subsequent transport and sedimentation. In the case of radionuclides with lower partition coefficients, release from the sediments to the water column followed by transport of dissolved radionuclides by currents plays a larger role. A significant result of the modelling was the quantification of the seasonal and spatial variation in radionuclide accumulation and in bioconcentration factors (BCFs) with spatial variation of BCFs often ranging 2 to 3 orders of magnitude. This variation was dominated by spatial differences in concentrations of radionuclides in water. In basins where radionuclides were introduced by groundwater flow, BCFs were typically 2-3 orders of magnitude lower than in deep basins without radionuclide release in the groundwater. In phytoplankton and grazers, bioconcentration factors (BCFs) scaled linearly to partition coefficients (Kd), underlining the fact that adsorption is an important process for radionuclide accumulation in the lower parts of the food web

  12. Evaluation of angiography performed by radiographers and nurses

    International Nuclear Information System (INIS)

    Chalmers, N.; Conway, B.; Andrew, H.; Parkinson, A.; Butterfield, J.S.; Fawcitt, R. A.

    2002-01-01

    AIM: To evaluate out-patient angiography performed by nurses and radiographers. MATERIALS AND METHODS: A protocol for out-patient angiography performed by nurses and radiographers was drawn up and approved by the Trust's Risk Management Committee. Following training, two experienced radiographers and one nurse undertook elective peripheral or renal angiography according to the protocol on 187 patients. Angiograms were performed using a 3F catheter introduced into the abdominal aorta from a femoral approach. Patients were discharged after 2 hours and contacted by telephone the following morning. RESULTS: No patient refused consent for the procedure. One hundred and seventy-two patients underwent successful catheterization without assistance from a radiologist. Radiologist assistance was required with femoral puncture or catheter/guidewire manipulation in 15 cases (8%). Images were considered diagnostic by the reporting radiologist in all but one case. This patient was recalled for further aortogram and pressure measurements. There was a single puncture site complication due to transient stenosis of the common femoral artery at the puncture site. This is thought to have been the result of subintimal injection of local anaesthetic, and it resolved spontaneously over 30 minutes. There were no delayed complications. CONCLUSION: Experienced nurses and radiographers can rapidly acquire the skills to perform diagnostic angiography safely and efficiently. Chalmers, N. et al. (2002)

  13. Transfer of fallout radionuclides derived from Fukushima NPP accident: 1 year study on transfer of radionuclides through hydrological processes

    Science.gov (United States)

    Onda, Yuichi; Kato, Hiroaki; Patin, Jeremy; Yoshimura, Kazuya; Tsujimura, Maki; Wakahara, Taeko; Fukushima, Takehiko

    2013-04-01

    Previous experiences such as Chernobyl Nuclear Power Plant accident have confirmed that fallout radionuclides on the ground surface migrate through natural environment including soils and rivers. Therefore, in order to estimate future changes in radionuclide deposition, migration process of radionuclides in forests, soils, ground water, rivers should be monitored. However, such comprehensive studies on migration through forests, soils, ground water and rivers have not been conducted so far. Here, we present the following comprehensive investigation was conducted to confirm migration of radionuclides through natural environment including soils and rivers. 1)Study on depth distribution of radiocaesium in soils within forests, fields, and grassland 2)Confirmation of radionuclide distribution and investigation on migration in forests 3)Study on radionuclide migration due to soil erosion under different land use 4)Measurement of radionuclides entrained from natural environment including forests and soils 5)Investigation on radionuclide migration through soil water, ground water, stream water, spring water under different land use 6)Study on paddy-to-river transfer of radionuclides through suspended sediments 7)Study on river-to-ocean transfer of radionuclides via suspended sediments 8)Confirmation of radionuclide deposition in ponds and reservoirs

  14. Digital subtraction angiography of the thoracic aorta

    International Nuclear Information System (INIS)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-01-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram

  15. Digital subtraction angiography of the thoracic aorta

    Energy Technology Data Exchange (ETDEWEB)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-02-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram.

  16. Clinical application of digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Morimoto, Tadashi; Kaku, Suiei; Morikawa, Eiji

    1984-01-01

    Intra-arterial digital subtraction angiography (IA-DSA) by the direct puncture of the carotid artery was described with special reference to its techniques, and cases were presented. This method was safe and painless and could be performed repeatedly. Cerebral angiographic images obtained by this method were either superior or fully compatible to the conventional cerebral angiography. It is therefore of great diagnostic value and can replace the conventional method. Furthermore, since the pretreatment is unnecessary and the time required is short, IA-DSA can be used as an adjuvant method for emergency diagnosis. (Namekawa, K)

  17. Application of longitudinal magnification effect to magnification stereoscopic angiography. A new method of cerebral angiography

    Energy Technology Data Exchange (ETDEWEB)

    Doi, K.; Rossmann, K.; Duda, E.E.

    1976-01-01

    A new method of stereoscopic cerebral angiography was developed which employs 2X radiographic magnification. In order to obtain the same depth perception in the object as with conventional contact stereoscopic angiography, one can make the x-ray exposures at two focal spot positions which are separated by only 1 inch, whereas the contact technique requires a separation of 4 inches. The smaller distance is possible because, with 2X magnification, the transverse detail in the object is magnified by a factor of two, but the longitudinal detail, which is related to the stereo effect, is magnified by a factor of four, due to the longitudinal magnification effect. The small focal spot separation results in advantages such as improved stereoscopic image detail, better image quality, and low radiation exposure to the patient.

  18. Application of longitudinal magnification effect to magnification stereoscopic angiography. A new method of cerebral angiography

    International Nuclear Information System (INIS)

    Doi, K.; Rossmann, K.; Duda, E.E.

    1976-01-01

    A new method of stereoscopic cerebral angiography was developed which employs 2X radiographic magnification. In order to obtain the same depth perception in the object as with conventional contact stereoscopic angiography, one can make the x-ray exposures at two focal spot positions which are separated by only 1 inch, whereas the contact technique requires a separation of 4 inches. The smaller distance is possible because, with 2X magnification, the transverse detail in the object is magnified by a factor of two, but the longitudinal detail, which is related to the stereo effect, is magnified by a factor of four, due to the longitudinal magnification effect. The small focal spot separation results in advantages such as improved stereoscopic image detail, better image quality, and low radiation exposure to the patient

  19. Early diagnosis of retinopathy in juvenile diabetes by fluorescence angiography

    International Nuclear Information System (INIS)

    Krzywicki, S.; Slankiewicz, A.; Jablonska-Budaj, U.

    1980-01-01

    The authors defined the usefulness of the fluorescein angiography of the retina and choroid in the early stage diagnosis of diabetic retinopathy in children comparing its results to the traditional ophthalmoscopy. Examination involved 50 children from 4 to 18 (30 boys and 20 girls) on insulin treatment. The duration of the disease was 1 to 14 years (average 7.36 years). Ophthalmoscopy showed pathological changes in 24% of the children. The fluorescein angiography visualized more microaneurysms compared to ophthalmoscopy and showed them sometimes in the eyes where they had not been found in eye fundus studies. By means of angiography the early and advanced stages of vascular complications were found in 64% of patients. Comparing to ophthalmoscopy a 40% increase was noted. Fluorescein angiography can lead to the decrease in the number of patients with markedly impaired visual acuity and cases of blindness in the diabetic population. (author)

  20. Early diagnosis of retinopathy in juvenile diabetes by fluorescence angiography

    Energy Technology Data Exchange (ETDEWEB)

    Krzywicki, S; Slankiewicz, A; Jablonska-Budaj, U [Szpital-Pomnik Centrum Zdrowia Dziecka, Warsaw (Poland). Zespol Problemowy Okulistiky

    1980-09-01

    The authors defined the usefulness of the fluorescein angiography of the retina and choroid in the early stage diagnosis of diabetic retinopathy in children comparing its results to the traditional ophthalmoscopy. Examination involved 50 children from 4 to 18 (30 boys and 20 girls) on insulin treatment. The duration of the disease was 1 to 14 years (average 7.36 years). Ophthalmoscopy showed pathological changes in 24% of the children. The fluorescein angiography visualized more microaneurysms compared to ophthalmoscopy and showed them sometimes in the eyes where they had not been found in eye fundus studies. By means of angiography the early and advanced stages of vascular complications were found in 64% of patients. Comparing to ophthalmoscopy a 40% increase was noted. Fluorescein angiography can lead to the decrease in the number of patients with markedly impaired visual acuity and cases of blindness in the diabetic population.

  1. Delayed angiography in the investigation of intracerebral hematomas caused by small arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Willinsky, R.A. (Dept. of Radiology, Toronto Hospital, Western Div., Toronto, ON (Canada) Univ. of Toronto, Brain Vascular Malformation Study Group, ON (Canada)); Fitzgerald, M. (Dept. of Radiology, Toronto Hospital, Western Div., Toronto, ON (Canada)); TerBrugge, K. (Dept. of Radiology, Toronto Hospital, Western Div., Toronto, ON (Canada) Univ. of Toronto, Brain Vascular Malformation Study Group, ON (Canada)); Montanera, W. (Dept. of Radiology, Toronto Hospital, Western Div., Toronto, ON (Canada)); Wallace, M. (Div. of Neurosurgery, Dept. of Surgery, Toronto Hospital, Western Div., ON (Canada) Univ. of Toronto, Brain Vascular Malformation Study Group, ON (Canada))

    1993-04-01

    We reviewed the clinical and radiological features of ten patients with small arteriovenous malformations that caused intracerebral hematomas. In six patients, angiography showed a small nidus (less than 1 cm in diameter) with a shunt at the site of the hematoma, and in four only an early-filling vein was evident. Six patients had only delayed angiography (4 weeks or more after the ictus). In three, angiography within 2 days of the ictus failed to reveal the cause of the bleed, but repeat angiography showed an early-filling vein in two, and a nidus with shunting in one. In only one patient did early angiography reveal the malformation. MRI was obtained in eight patients, and in two prominent vessels were evident in the wall of the hematoma cavity. In investigation of an unexplained intracerebral hematoma, MRI may be useful to exclude a neoplasm or cavernoma, although the latter may be not be evident in the presence of a recent hematoma. We suggest early MRI and angiography for investigation of an unexplained, nonhypertensive intracerebral bleed, with follow-up MRI and dealyed angiography if the initial studies fail to reveal the cause. (orig.)

  2. Three-dimensional magnetic resonance angiography of vascular lesions in children.

    Science.gov (United States)

    Katayama, H; Shimizu, T; Tanaka, Y; Narabayashi, I; Tamai, H

    2000-01-01

    We applied three-dimensional (3D) magnetic resonance (MR) angiography to vascular lesions in children and evaluated the clinical usefulness of this technique. Ten patients, whose ages ranged from 1 month to 16 years, underwent 3D MR angiography for 12 vascular lesions, including lesions in seven pulmonary arteries, two thoracic aortae, a pair of renal arteries, and one iliac artery. Three-dimensional MR angiography was performed with body-or pelvic-phased array coils on a 1.5-T scanner using fast spoiled gradient echo sequence. Data were acquired with the following parameters: TE, 1.9 ms; TR, 10.1 ms; flip angle, 20-60 degrees ; 1 or 2 NEX; field of view, 24-48 x 18-40 cm; matrix, 256 or 512 x 128 or 256; slice thickness, 1.2-7.5 mm; and 12, 28, or 60 partitions. Vascular imaging was enhanced with 20% gadolinium-diethylenetriaminepentaacetic acid. The examination was performed under breath-holding in six patients and with shallow breathing in four patients. In a comparative study with other noninvasive methods, 3D MR angiography was superior in seven of nine cases to other noninvasive examinations and in two cases, all methods evaluated the lesions. Furthermore, six cases were compared with conventional angiography. In five of the six cases, both methods depicted the lesions similarly, and in one case, MR angiography was more effective. A quantitative comparison of vascular diameter in the MR image was made with that in the conventional angiographic image. The correlation between them was excellent: y = 1.145x-2.090 (r = 0.987; P children.

  3. Digital subtraction angiography in pediatric cerebrovascular occlusive disease

    International Nuclear Information System (INIS)

    Faerber, E.N.; Griska, L.A.B.; Swartz, J.D.; Capitanio, M.A.; Popky, G.L.

    1984-01-01

    While conventional angiography has been used to demonstrate cerebrovascular occlusive disease in the past, digital subtraction angiography (DSA) is capable of showing progressive vascular involvement with ease, simplicity, and extremely low morbidity, making it particularly well suited for children and outpatients either alone or coordinated with computed tomography. The authors discuss the usefulness and advantages of DSA as demonstrated in 7 infants and children with hemiplegia, 4 of whom had sickle-cell disease

  4. Contrast settling in cerebral aneurysm angiography

    International Nuclear Information System (INIS)

    Wang Zhijie; Hoffmann, Kenneth R; Guterman, Lee R; Wang Zhou; Rudin, Stephen; Meng Hui

    2005-01-01

    During angiography, blood flow is visualized with a radiopaque contrast agent, which is denser than blood. In complex vasculature, such as cerebral saccular aneurysms, the density difference may produce an appreciable gravity effect, where the contrast material separates from blood and settles along the gravity direction. Although contrast settling has been occasionally reported before, the fluid mechanics behind it have not been explored. Furthermore, the severity of contrast settling in cerebral aneurysms varies significantly from case to case. Therefore, a better understanding of the physical principles behind this phenomenon is needed to evaluate contrast settling in clinical angiography. In this study, flow in two identical groups of sidewall aneurysm models with varying parent-vessel curvature was examined by angiography. Intravascular stents were deployed into one group of the models. To detect contrast settling, we used lateral view angiography. Time-intensity curves were analysed from the angiographic data, and a computational fluid dynamic analysis was conducted. Results showed that contrast settling was strongly related to the local flow dynamics. We used the Froude number, a ratio of flow inertia to gravity force, to characterize the significance of gravity force. An aneurysm with a larger vessel curvature experienced higher flow, which resulted in a larger Froude number and, thus, less gravitational settling. Addition of a stent reduced the aneurysmal flow, thereby increasing the contrast settling. We found that contrast settling resulted in an elevated washout tail in the time-intensity curve. However, this signature is not unique to contrast settling. To determine whether contrast settling is present, a lateral view should be obtained in addition to the anteroposterior (AP) view routinely used clinically so as to rule out contrast settling and hence to enable a valid time-intensity curve analysis of blood flow in the aneurysm

  5. Conventional and CT angiography in children: dosimetry and dose comparisons

    International Nuclear Information System (INIS)

    Frush, Donald P.; Yoshizumi, Terry

    2006-01-01

    Tremendous advances have been made in imaging in children with both congenital and acquired heart disease. These include technical advances in cardiac catheterization and conventional angiography, especially with advancements in interventional procedures, as well as noninvasive imaging with MR and CT angiography. With rapid advances in multidetector CT (MDCT) technology, most recently 64-detector array systems (64-slice MDCT), have come a number of advantages over MR. However, both conventional and CT angiography impart radiation dose to children. Although the presence of radiation exposure to children has long been recognized, it is apparent that our ability to assess this dose, particularly in light of the rapid advancements, has been limited. Traditional methods of dosimetry for both conventional and CT angiography are somewhat cumbersome or involve a potential for substantial uncertainty. Recent developments in dosimetry, including metal oxide semiconductor field effect transistors (MOSFET) and the availability of anthropomorphic, tissue-equivalent phantoms have provided new opportunities for dosimetric assessments. Recent work with this technology in state-of-the-art cardiac angiography suites as well as with MDCT have offered direct comparisons of doses in infants and children undergoing diagnostic cardiac evaluation. It is with these dose data that assessment of risks, and ultimately the assessment of risk-benefit, can be better achieved. (orig.)

  6. Hepatic Artery Angiography and Embolization for Hemobilia Following Laparoscopic Cholecystectomy

    International Nuclear Information System (INIS)

    Nicholson, Tony; Travis, Simon; Ettles, Duncan; Dyet, John; Sedman, Peter; Wedgewood, Kevin; Royston, Christopher

    1999-01-01

    Purpose: The effectiveness of angiography and embolization in diagnosis and treatment were assessed in a cohort of patients presenting with upper gastrointestinal hemorrhage secondary to hepatic artery pseudoaneurysm following laparoscopic cholecystectomy. Methods: Over a 6-year period 1513 laparoscopic cholecystectomies were carried out in our region. Nine of these patients (0.6%) developed significant upper gastrointestinal bleeding, 5-43 days after surgery. All underwent emergency celiac and selective right hepatic artery angiography. All were treated by coil embolization of the right hepatic artery proximal and distal to the bleeding point. Results: Pseudoaneurysms of the hepatic artery adjacent to cholecystectomy clips were demonstrated in all nine patients at selective right hepatic angiography. In three patients celiac axis angiography alone failed to demonstrate the pseudoaneurysm. Embolization controlled hemorrhage in all patients with no further bleeding and no further intervention. One patient developed a candidal liver abscess in the post-procedure period. All patients are alive and well at follow-up. Conclusion: Selective right hepatic angiography is vital in the diagnosis of upper gastrointestinal hemorrhage following laparoscopic cholecystectomy. Embolization offers the advantage of minimally invasive treatment in unstable patients, does not disrupt recent biliary reconstruction, allows distal as well as proximal control of the hepatic artery, and is an effective treatment for this potentially life-threatening complication

  7. Prediction of parent artery of anterior communicating artery aneurysm on CT angiography

    International Nuclear Information System (INIS)

    Chung, Jin Young; Han, Tae Il; Kim, Dae Hong; Han, Hyun Young; Kim, Hyun Jung; Song, Mun Kab

    1999-01-01

    To determine whether CT angiography can predict the parent artery of an anterior communicating aneurysm on the basis of characteristics of the aneurysm and precommunication anterior cerebral artery. Eighteen patients with anterior communication aneurysm were studied prospectively using CT angiography and conventional angiography. The parent artery of an aneurysm was predicted by evaluating aneurysm neck location, direction of aneurysm projection, and size of the precommunicating anterior cerebral artery, as seen on CT angiography. A somatom Plus-4 spiral CT scanner was used and shaded-surface display three-dimensional images were constructed. Aneurysm neck was located near the parent artery in 12 cases(66.7%), and aneurysm projection was against the parent artery in 11 cases(61.1%). The parent artery of the anterior cerebral artery was larger in 15 cases(83.3%), including ten cases of hypoplasia or agenesis of the contralateral anterior cerebral artery. In 17 of 18 aneurysms(94.4%) the parent artery seen on DSA was correctly predicted by CT angiography. The parent artery of an anterior communicating aneurysm can be predicted by evaluating aneurysm neck location, direction of aneurysm projection, and precommunicating anterior cerebral artery, as seen on CT angiography

  8. Conditions and processes affecting radionuclide transport

    Science.gov (United States)

    Simmons, Ardyth M.; Neymark, Leonid A.

    2012-01-01

    Characteristics of host rocks, secondary minerals, and fluids would affect the transport of radionuclides from a previously proposed repository at Yucca Mountain, Nevada. Minerals in the Yucca Mountain tuffs that are important for retarding radionuclides include clinoptilolite and mordenite (zeolites), clay minerals, and iron and manganese oxides and hydroxides. Water compositions along flow paths beneath Yucca Mountain are controlled by dissolution reactions, silica and calcite precipitation, and ion-exchange reactions. Radionuclide concentrations along flow paths from a repository could be limited by (1) low waste-form dissolution rates, (2) low radionuclide solubility, and (3) radionuclide sorption onto geological media.

  9. CAPILLARY NETWORK ANOMALIES IN BRANCH RETINAL VEIN OCCLUSION ON OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    Science.gov (United States)

    Rispoli, Marco; Savastano, Maria Cristina; Lumbroso, Bruno

    2015-11-01

    To analyze the foveal microvasculature features in eyes with branch retinal vein occlusion (BRVO) using optical coherence tomography angiography based on split spectrum amplitude decorrelation angiography technology. A total of 10 BRVO eyes (mean age 64.2 ± 8.02 range between 52 years and 76 years) were evaluated by optical coherence tomography angiography (XR-Avanti; Optovue). The macular angiography scan protocol covered a 3 mm × 3 mm area. The focus of angiography analysis were two retinal layers: superficial vascular network and deep vascular network. The following vascular morphological congestion parameters were assessed in the vein occlusion area in both the superficial and deep networks: foveal avascular zone enlargement, capillary non-perfusion occurrence, microvascular abnormalities appearance, and vascular congestion signs. Image analyses were performed by 2 masked observers and interobserver agreement of image analyses was 0.90 (κ = 0.225, P network of BRVO, a decrease in capillary density with foveal avascular zone enlargement, capillary non-perfusion occurrence, and microvascular abnormalities appearance was observed (P network showed the main vascular congestion at the boundary between healthy and nonperfused retina. Optical coherence tomography angiography in BRVO allows to detect foveal avascular zone enlargement, capillary nonperfusion, microvascular abnormalities, and vascular congestion signs both in the superficial and deep capillary network in all eyes. Optical coherence tomography angiography technology is a potential clinical tool for BRVO diagnosis and follow-up, providing stratigraphic vascular details that have not been previously observed by standard fluorescein angiography. The normal retinal vascular nets and areas of nonperfusion and congestion can be identified at various retinal levels. Optical coherence tomography angiography provides noninvasive images of the retinal capillaries and vascular networks.

  10. CT angiography of the renal arteries and veins: normal anatomy and variants.

    Science.gov (United States)

    Hazırolan, Tuncay; Öz, Meryem; Türkbey, Barış; Karaosmanoğlu, Ali Devrim; Oğuz, Berna Sayan; Canyiğit, Murat

    2011-03-01

    Conventional angiography has long been regarded as gold standard imaging modality for evaluation of the renal vasculature. Introduction of multidetector computed tomography (MDCT) angiography had a groundbreaking impact on evaluation of the renal vessels and is gradually replacing conventional angiography as standard imaging. Herein, we review and illustrate the normal and variant anatomy of renal vessels with special emphasis on imaging protocols and reconstruction techniques in MDCT.

  11. Effects of projection and background correction method upon calculation of right ventricular ejection fraction using first-pass radionuclide angiography

    International Nuclear Information System (INIS)

    Caplin, J.L.; Flatman, W.D.; Dymond, D.S.

    1985-01-01

    There is no consensus as to the best projection or correction method for first-pass radionuclide studies of the right ventricle. We assessed the effects of two commonly used projections, 30 degrees right anterior oblique and anterior-posterior, on the calculation of right ventricular ejection fraction. In addition two background correction methods, planar background correction to account for scatter, and right atrial correction to account for right atrio-ventricular overlap were assessed. Two first-pass radionuclide angiograms were performed in 19 subjects, one in each projection, using gold-195m (half-life 30.5 seconds), and each study was analysed using the two methods of correction. Right ventricular ejection fraction was highest using the right anterior oblique projection with right atrial correction 35.6 +/- 12.5% (mean +/- SD), and lowest when using the anterior posterior projection with planar background correction 26.2 +/- 11% (p less than 0.001). The study design allowed assessment of the effects of correction method and projection independently. Correction method appeared to have relatively little effect on right ventricular ejection fraction. Using right atrial correction correlation coefficient (r) between projections was 0.92, and for planar background correction r = 0.76, both p less than 0.001. However, right ventricular ejection fraction was far more dependent upon projection. When the anterior-posterior projection was used calculated right ventricular ejection fraction was much more dependent on correction method (r = 0.65, p = not significant), than using the right anterior oblique projection (r = 0.85, p less than 0.001)

  12. MR and angiography: Evaluation of the hemodynamics of portal hypertension

    International Nuclear Information System (INIS)

    Torres, W.E.; Gaylord, G.M.; Whitmire, L.; Chuang, V.P.; Bernardino, M.E.

    1986-01-01

    Forty-two MR imaging examinations and angiographic procedures in 38 patients with portal hypertension were compared for how well the images depicted portal perfusion and direction of flow, portal vein thrombosis, and the presence and type of shunt. Thirty-three MR imaging studies indicated grade I or II portal flow. In 29 cases portal flow was grade I or II by angiography; in the remaining cases the flow was grade IV. In a total of eight cases portal flow was grade IV by angiography, but none appeared to be grade IV on MR imaging. Both MR imaging and angiography detected portal vein thrombosis (41 of 42 cases). MR imaging and angiography agreed as to whether a shunt was present or absent, and patent or occluded (41 of 42 cases). Currently, MR imaging is an unsatisfactory modality by which to grade portal flow. MR imaging does depict portal vein thrombosis well, and can be used to determine patency of surgical shunts

  13. Intraarterial digital subtraction angiography applied to diagnosis of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, Sadahiko; Sano, Akira; Imanaka, Kazufumi; Sasai, Keisuke; Nagae, Toshiyuki; Mizutani, Masaru; Hatabu, Hiroto; Sadatou, Norihiro; Kuroda, Yasumasa

    1985-12-01

    This paper deals with diagnostic values of intraarterial digital subtraction angiography (IADSA) for evaluating hepatocellular carcinoma. The present series consists of 44 patients with hepatocellular carcinoma, who underwent IADSA combined with conventional hepatic angiography 67 times in total. The evaluated vessels by IADSA included 70 hepatic arteries and 36 portal veins. Comparative studies on the image quality of IADSA with conventional angiography were made in referring to the tumor stain for arteriograms and resolution of intrahepatic portal branches for portograms. Diagnostic superiority including equality of DSA image to conventional was noted in arteriograms: 72.7 % in the right lobe and 86 % in the left. Most deteriorated DSA images were caused by misregistration artifacts. IADSA portography revealed basically diagnostic values to demonstrate lobar, segmental or more peripheral branches in about 95 % of cases studied. DSA, characterized by high contrast resolution and real-time subtraction, offered important and effective informations for interventional angiography as well as resectability of the tumors, requiring less contrast medium.

  14. Diagnosis of clinical staging of bladder cancer by CT and angiography

    International Nuclear Information System (INIS)

    Kobayashi, Isao; Igawa, Mikio; Ohnishi, Yoshio; Nakano, Hiroshi; Nihira, Hiromi; Mori, Masaki; Okada, Mitsuo.

    1984-01-01

    The preoperative staging of bladder cancer is of fundamental importance for prognostic evaluation and surgical indication. We studied the accuracy of computed tomography (CT) and angiography in defining the extent of local invasion in 16 patients with surgically proven carcinoma of the bladder. The overall accuracy of CT and angiographic staging in these cases was 75 % and 50 % respectively. In low stage, the accuracy was 90 % in CT and 70 % in angiography. In high stage, the accuracy was 50 % in CT and 16.7 % in angiography. Our results seems to indicate lower accuracy in high stage bladder cancer compared with other research. Data from a much larger series are required to ascertain whether the additional information provided by CT and angiography will produce any improvement in patient management. (author)

  15. A chemical basis for the partitioning of radionuclides in incinerator operation

    International Nuclear Information System (INIS)

    Burger, L.L.

    1995-01-01

    Incineration as a method of treating radioactive or mixed waste is attractive because of volume reduction, but may result in high concentrations of some hazardous components. For safety reasons during operation, and because of the environmental impact of the plant, it is important to know how these materials partition between the furnace slay, the fly ash, and the stack emission. The chemistry of about 50 elements is discussed and through consideration of high temperature thermodynamic equilibria, an attempt is made to provide a basis for predicting how various radionuclides and heavy metals behave in a typical incinerator. The chemistry of the individual elements is first considered and a prediction of the most stable chemical species in the typical incinerator atmosphere is made. The treatment emphasizes volatility and the parameters considered are temperature, acidity, oxygen, sulfur, and halogen content, and the presence of several other key non-radioactive elements. A computer model is used to calculate equilibrium concentrations of many species in several systems at temperatures ranging from 500 to 1600 degrees K. It is suggested that deliberate addition of various feed chemicals can have a major impact on the fate of many radionuclides and heavy metals. Several problems concerning limitations and application of the data are considered

  16. Dynamic modelling of radionuclide uptake by Fukushima coastal biota - Dynamic modelling of radionuclide uptake by marine biota: application to Fukushima assessment

    Energy Technology Data Exchange (ETDEWEB)

    Vives i Batlle, Jordi [Belgian Nuclear Research Centre, Boeretang 200, 2400 Mol (Belgium)

    2014-07-01

    Radiological assessments to non-human marine biota are usually carried out by assuming that the activity concentration in an organism is proportional to the activity concentration in an adjacent volume of water, via a concentration factor (CF). It is also assumed that radionuclides in the water are in isotopic equilibrium with the sediments via a sediment distribution coefficient (K{sub d}). These assumptions are not valid in accidental situations where the biota and the sediments react with a time delay to large variations of activity concentration in seawater. A simple dynamic model was developed to factorise the dynamics of radionuclide uptake and turnover in biota and sediments, as determined by a balance between the residence time of radionuclides in seawater/sediments and the biological half-life of elimination in the biota. The model calculates activity concentration of {sup 131}I, {sup 134}Cs, {sup 137}Cs and {sup 90}Sr in seabed sediment, fish, crustaceans, molluscs and macro-algae from surrounding activity concentrations in seawater, with which to derive internal and external dose rates. A central element of this new model is the inclusion of sediment processes in dynamic transfer modelling. The model is adapted to include depletion of radionuclides adsorbed onto suspended particulates (particle scavenging), molecular diffusion, pore water mixing and bioturbation (modelled effectively as a diffusive process) represented by a simple set of differential equations that is coupled with the biological uptake/turnover processes. In this way, the model is capable of reproducing activity concentration in sediment to give a more realistic calculation of the external dose to biota compared with the simpler approach based on CF and K{sub d} values used in previous assessments. The model is applied to the assessment of the radiological impact of the Fukushima accident on marine biota in the early phase of the accident. It is shown that previous assessment of the

  17. Clinical application of electron beam computed tomography in intravenous three-dimensional coronary angiography

    International Nuclear Information System (INIS)

    Luo Chufan; Du Zhimin; Hu Chengheng; Li Yi; Zeng Wutao; Ma Hong; Li Xiangmin; Zhou Xuhui

    2002-01-01

    Objective: To investigate the clinical application of intravenous three-dimensional coronary angiography using electron beam computed tomography (EBCT) as compared with selective coronary angiography. Methods: Intravenous EBCT and selective coronary angiography were performed during the same period in 38 patients. The value of EBCT angiography for diagnosing coronary artery disease was evaluated. Results: The number of coronary arteries adequately evaluated by EBCT angiography was 134 out of 152 vessels (88.2%), including 100% of the left main coronary arteries, 94.7% of the left anterior descending arteries, 81.6% of the left circumflex arteries and 76.3 % of the right coronary arteries. Significantly more left main and heft anterior descending coronary arteries were adequately visualized than the left circumflex and right coronary arteries (P < 0.05). The sensitivity, specificity, accuracy, and positive and negative predictive value of EBCT angiography for diagnosing coronary artery disease were 88.0%, 84.6%, 86.8%, 91.7% and 78.6%, respectively. Of the 38 arteries with ≥ 50% stenosis, EBCT underestimated 8, for a sensitivity of 78.9%. Of the 96 arteries without significant stenosis, EBCT overestimated 7 stenosis, for a specificity of 92.7%. Conclusion: Intravenous electron beam computed tomographic coronary angiography is a promising noninvasive method for diagnosing coronary artery disease

  18. Radionuclides in air, water, and biota

    International Nuclear Information System (INIS)

    Seymour, A.H.; Nelson, V.A.

    1977-01-01

    Air, water, and biological samples collected before and after the 1965, 1969, and 1971 underground nuclear detonations at Amchitka Island were analyzed for natural and fallout radionuclides by gamma spectrometry. Selected samples were also analyzed for tritium, 55 Fe, and 90 Sr. The objectives were to search for and identify radionuclides of Amchitka origin in the samples and to contribute to the general knowledge of the distribution of radionuclides in the environment. The studies showed that there has been no escape of radionuclides from the underground sites of the three nuclear detonations at Amchitka Island except for trace quantities of radionuclides, principally tritium, in water and soil gas samples from the immediate vicinity of the surface ground zero for the 1965 event. Two naturally occurring radionuclides, 40 K and 7 Be, were the most abundant radionuclides in the samples, usually by a factor of 10 or more, except for 137 Cs in lichen samples. All levels were well below applicable Radiation Protction Guides, often being near the statistical limit of detection

  19. Phytoremediation of radionuclides: an emerging alternative

    International Nuclear Information System (INIS)

    Singh, Shraddha

    2013-01-01

    Proliferation of nuclear power industry, nuclear weapon testing, dismantling of existing nuclear weapons and occasional accidents have contributed to an enhancement in the level of radionuclides in the environment. The radionuclides due to their long half life and transfer through the food chain effect adversely to normal biological systems. Hence, it is essential to effectively remove the radionuclides from contaminated soils and solutions. Phytoremediation - the use of plants for remediation of toxic metals and radionuclides has been recognized as an aesthetically pleasing, low cost and environment friendly in situ method. Phytoremediation is an umbrella term which covers several plant based approaches. Plants have shown the potential of remediation of these radionuclides from spiked solutions, low level nuclear waste and soil. Various aspects of phytoremediation as well as potential of various plants for remediation of radionuclides will be discussed here. (author)

  20. Analysis of end-systolic pressure-volume relation by gated radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Adachi, Haruhiko; Sugihara, Horoki; Katsume, Hiroshi; Ijichi, Hamao; Miyanaga, Hajime

    1982-01-01

    Left ventricular end-systolic pressure-volume relation has been proved experimentally to b e an useful index of left ventricular contractility relatively independent of preload or afterload. But less clinical application has been reported because of its invasive nature, and we evaluated this relationship non-invasively using gated radionuclide angiocardiography as volume determination and cuff sphyngomanometer in the arm as pressure measurement. Gated equilibrium blood pool scintigrams were obtained at rest and during intravenous infusion of angiotensin or nitrate. Ventricular volumes were derived from ventricular activity and peripheral blood volume and activity. The peak systolic pressure (PSP) by cuff method to end-systolic volume index (ESVI) relations showed good linearity (r gt .930 in 84% of consecutive 50 cases) and were gentler in the groups with more impaired left ventricular function. Emax was related exponentially to ejection fraction (EF) and hyperbolically to end-diastolic volume index. The dead volume (VoI) was unfixed and fell into positive or negative value, and was not related to EF under control condition. PSP/ESVI in each loading condition was less variable with the alteration of blood pressure than EF. The linear relation was found between PSP/ESVI under control condition and Emax (PSP/ESVI = 0.651.Emax + 0.958, r = 0.841, p lt .001). Thus in measuring ventricular volume, gated radionuclide angiocardiography is a non-invasive method less affected by the geometry of the left ventricle. Non-invasive determination of end-systolic pressure-volume relation using the volume by radionuclide and the blood pressure by cuff method is clinically useful in the assessment of left ventricular contractility. (author)