WorldWideScience

Sample records for epithermal neutrons activation

  1. Epithermal neutron activation analysis of food

    International Nuclear Information System (INIS)

    Zikovsky, L.; Soliman, K.

    1999-01-01

    Food samples were irradiated with thermal and epithermal neutrons. The average ratios of thermal to epithermal activity were determined for 80 Br, 49 Ca, 38 Cl, 60m Co, 42 K, 27 Mg, 56 Mn, 24 Na, and 86m Rb. They were equal to 2.1, 26, 24, 6.6, 19, 16, 11, 23 and 1.9, respectively. Then, 57 food samples were analyzed by epithermal neutron activation analysis for Br and Rb. The concentrations (in ppm) of Br and Rb were in asparagus (2) 2.3, 11.5; beets (3) 0.5, 0.8; beef (3) 1.7, 3.6; cabbage (5) 0.5, 10.8; carrot (3) 0.2, 3.7; chicken (3) 0.6, 4.4; chocolate (7) 11.1, 18.7; egg (3) 0.9, 1.9; french bean (3) 0.3, 1.0; goose (2) 1.3, 9.3; lettuce (2) 0.9, 1.7; pork (1) 1.5, 4.4; potato (7) 1.0, 1.2; sausage (3) 4.8, 3.5; spinach (3) 3.6, 4.0; strawberry jam (3) 0.4, 1.4; tomato (1) 13.5, 14.6; turkey (3) 1.2, 4.9. respectively. The number of samples and analyzed is indicated in parentheses. (author)

  2. Epithermal neutron activation analysis using a boron carbide irradiation filter

    International Nuclear Information System (INIS)

    Ehmann, W.D.; Brueckner, J.

    1980-01-01

    The use of boron carbide as a thermal neutron filter in epithermal neutron activation (ENAA) analysis has been investigated. As compared to the use of a cadmium filter, boron provides a greater reduction of activities from elements relatively abundant in terrestrial rocks and fossil fuels, such as Na, La, Sc and Fe. These elements have excitation functions which follow the 1/v law in the 1 to 10 eV lower epithermal region. This enhances the sensitivity of ENAA for elements such as U, Th, Ba and etc. which have strong resonances in the higher epithermal region above 10 eV. In addition, a boron carbide filter has the advantages over cadmium of acquiring a relatively low level of induced activity which poses minimal radiation safety problems, when used for ENAA. (author)

  3. Determination of silver using cyclic epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Pun, T.H.; Landsberger, S.

    2012-01-01

    A fast pneumatic transfer facility was installed in Nuclear Engineering Teaching Laboratory (NETL) of the University of Texas at Austin for the purpose of cyclic thermal and epithermal neutron activation analysis. In this study efforts were focused on the evaluation of cyclic epithermal neutron activation analysis (CENAA). Various NIST and CANMET certified materials were analyzed by the system. Experiment results showed 110 Ag with its 25 s half-life as one of the isotopes favored by the system. Thus, the system was put into practical application in identifying silver in metallic ores. Comparison of sliver concentrations as determined by CENAA in CANMET certified reference materials gave very good results. (author)

  4. Directional epithermal neutron detector

    International Nuclear Information System (INIS)

    Givens, W.W.; Mills, W.R. Jr.

    1986-01-01

    A borehole tool for epithermal neutron die-away logging of subterranean formations surrounding a borehole is described which consists of: (a) a pulsed source of fast neutrons for irradiating the formations surrounding a borehole, (b) at least one neutron counter for counting epithermal neutrons returning to the borehole from the irradiated formations, (c) a neutron moderating material, (d) an outer thermal neutron shield providing a housing for the counter and the moderating material, (e) an inner thermal neutron shield dividing the housing so as to provide a first compartment bounded by the inner thermal neutron shield and a first portion of the outer thermal neutron shield and a second compartment bounded by the inner thermal neutron shield and a second portion of the outer thermal neutron shield, the counter being positioned within the first compartment and the moderating material being positioned within the second compartment, and (f) means for positioning the borehole tool against one side of the borehole wall and azimuthally orienting the borehole tool such that the first chamber is in juxtaposition with the borehole wall, the formation epithermal neutrons penetrating into the first chamber through the first portion of the outer thermal neutron shield are detected by the neutron counter for die-away measurement, thereby maximizing the directional sensitivty of the neutron counter to formation epithermal neutrons, the borehole fluid epithermal neutrons penetrating into the second chamber through the second chamber through the second portion of the outer thermal neutron shield are largely slowed down and lowered in energy by the moderating material and absorbed by the inner thermal neutron shield before penetrating into the first chamber, thereby minimizing the directional sensitivity of the neutron counter to borehole fluid epithermal neutrons

  5. Comparison of different methods for activation analysis of geological and pedological samples: Reactor and epithermal neutron activation, relative and monostandard method

    International Nuclear Information System (INIS)

    Alian, A.; Sansoni, B.

    1980-04-01

    Using purely instrumental methods, a comparative study is presented on neutron activation analysis of rock and soil samples by whole reactor neutron spectrum and epithermal neutrons with both relative and monostandard procedures. The latter procedure used with epithermal neutron activation analysis of soil samples necessitated the use of the 'effective resonance integrals' which were determined experimentally. The incorporation of the #betta# factor, representing deviation of reactor epithermal neutron flux from 1/E law, is developed in the present work. The main criteria for the choice of one or more of the procedures studied for a given purpose are also indicated. Analysis of 15 trace elements, Ca and Fe in the standard Japanese granite JG-1 using monostandard epithermal neutron activation gave results in good agreement with the average literature values. (orig./RB) [de

  6. Epithermal neutron instrumentation at ISIS

    International Nuclear Information System (INIS)

    Gorini, G; Festa, G; Andreani, C

    2014-01-01

    The advent of pulsed neutron sources makes available high epithermal neutron fluxes (in the energy range between 500 meV and 100 eV). New dedicated instrumentation, such as Resonance Detectors, was developed at ISIS spallation neutron source in the last years to apply the specific properties of this kind of neutron beam to the study of condensed matter. New detection strategies like Filter Difference method and Foil Cycling Technique were also developed in parallel to the detector improvement at the VESUVIO beamline. Recently, epithermal neutron beams were also used at the INES beamline to study elemental and isotopic composition of materials, with special application to cultural heritage studies. In this paper we review a series of epithermal neutron instrumentation developed at ISIS, their evolution over time and main results obtained

  7. Utilization of boron irradiation filters in reactor neutron activation via epithermal (n,γ) and fast neutron reactions

    International Nuclear Information System (INIS)

    Chisela, F.

    1986-01-01

    The technique of instrumental neutron activation analysis based on irradiation with reactor epithermal and fast neutrons has been described and evaluated. Important characteristics of boron neutron absorbers used to remove thermal neutrons from the reactor neutron spectrum have been examined and compared with those of cadmium. Three boron compound shields, have been designed and constructed at the BER II 5MW reactor for use in epithermal neutron activation analysis of biological materials. The major advantages offered by these filters in this application include the flexibility of varying the filter thickness, the low radioactivity induced in the filters during irradiation, ease of fabrication and the relatively low cost of the filter materials. The radiation heating due to the 10 B(n,α) 7 Li-reaction has been experimentally investigated for the filters used and the results obtained confirm the necessity for efficient cooling of these filters during irradiation. Three irradiation facilities have been characterized with respect to the neutron flux density and the flux spatial distribution. An experiment has been designed and carried out to compensate the flux inhomogeneity in two irradiation positions of the DBV facility caused by the reactor geometry. Several biological samples including well characterized reference materials have been analysed after epithermal activation and the results compared with those obtained with the classical thermal neutron activation method. Improved sensitivity of determination has been found for elements with high resonance integral to thermal neutron cross section ratios (RI/σ 0 ). The range of elements that can be determined instrumentally is extended and the time scale of analysis is considerably reduced. (orig.) [de

  8. Epithermal neutron beam interference with cardiac pacemakers

    International Nuclear Information System (INIS)

    Koivunoro, H.; Serén, T.; Hyvönen, H.; Kotiluoto, P.; Iivonen, P.; Auterinen, I.; Seppälä, T.; Kankaanranta, L.; Pakarinen, S.; Tenhunen, M.; Savolainen, S.

    2011-01-01

    In this paper, a phantom study was performed to evaluate the effect of an epithermal neutron beam irradiation on the cardiac pacemaker function. Severe malfunction occurred in the pacemakers after substantially lower dose from epithermal neutron irradiation than reported in the fast neutron or photon beams at the same dose rate level. In addition the pacemakers got activated, resulting in nuclides with half-lives from 25 min to 115 d. We suggest that BNCT should be administrated only after removal of the pacemaker from the vicinity of the tumor.

  9. Epithermal neutron beam interference with cardiac pacemakers

    Energy Technology Data Exchange (ETDEWEB)

    Koivunoro, H., E-mail: hanna.koivunoro@helsinki.fi [Department of Physics, P.O.B. 64, FI-00014 University of Helsinki (Finland)] [Department of Oncology, Helsinki University Central Hospital, P.O.B. 180, FIN-00029 HUS (Finland)] [Boneca Corporation, Finland, Filnland (Finland); Seren, T. [VTT Technical Research Centre of Finland (Finland); Hyvoenen, H. [Boneca Corporation, Finland, Filnland (Finland); Kotiluoto, P. [VTT Technical Research Centre of Finland (Finland); Iivonen, P. [St. Jude Medical (Finland); Auterinen, I. [VTT Technical Research Centre of Finland (Finland); Seppaelae, T.; Kankaanranta, L. [Department of Oncology, Helsinki University Central Hospital, P.O.B. 180, FIN-00029 HUS (Finland); Pakarinen, S. [Department of Cardiology, Helsinki University Central Hospital (Finland); Tenhunen, M. [Department of Oncology, Helsinki University Central Hospital, P.O.B. 180, FIN-00029 HUS (Finland); Savolainen, S. [HUS Helsinki Medical Imaging Center, Helsinki University Central Hospital (Finland)

    2011-12-15

    In this paper, a phantom study was performed to evaluate the effect of an epithermal neutron beam irradiation on the cardiac pacemaker function. Severe malfunction occurred in the pacemakers after substantially lower dose from epithermal neutron irradiation than reported in the fast neutron or photon beams at the same dose rate level. In addition the pacemakers got activated, resulting in nuclides with half-lives from 25 min to 115 d. We suggest that BNCT should be administrated only after removal of the pacemaker from the vicinity of the tumor.

  10. Determination of the thermal and epithermal neutron sensitivities of an LBO chamber

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Satoru; Kotani, Kei; Kajimoto, Tsuyoshi; Tanaka, Kenichi [Hiroshima University, Quantum Energy Applications, Graduate School of Engineering, Higashi-Hiroshima (Japan); Sato, Hitoshi; Nakajima, Erika [Ibaraki Prefectural University of Health Science, Radiological Sciences, Ibaraki (Japan); Shimazaki, Takuto [Hiroshima University, Quantum Energy Applications, Graduate School of Engineering, Higashi-Hiroshima (Japan); Delta Kogyo Co., Ltd., Hiroshima (Japan); Suda, Mitsuru; Hamano, Tsuyoshi [National Institute of Radiological Sciences, Chiba-Shi, Chiba (Japan); Hoshi, Masaharu [Hiroshima University, Institute for Peace Science, Hiroshima (Japan)

    2017-08-15

    An LBO (Li{sub 2}B{sub 4}O{sub 7}) walled ionization chamber was designed to monitor the epithermal neutron fluence in boron neutron capture therapy clinical irradiation. The thermal and epithermal neutron sensitivities of the device were evaluated using accelerator neutrons from the {sup 9}Be(d, n) reaction at a deuteron energy of 4 MeV (4 MeV d-Be neutrons). The response of the chamber in terms of the electric charge induced in the LBO chamber was compared with the thermal and epithermal neutron fluences measured using the gold-foil activation method. The thermal and epithermal neutron sensitivities obtained were expressed in units of pC cm{sup 2}, i.e., from the chamber response divided by neutron fluence (cm{sup -2}). The measured LBO chamber sensitivities were 2.23 x 10{sup -7} ± 0.34 x 10{sup -7} (pC cm{sup 2}) for thermal neutrons and 2.00 x 10{sup -5} ± 0.12 x 10{sup -5} (pC cm{sup 2}) for epithermal neutrons. This shows that the LBO chamber is sufficiently sensitive to epithermal neutrons to be useful for epithermal neutron monitoring in BNCT irradiation. (orig.)

  11. Pulsed neutron sources for epithermal neutrons

    International Nuclear Information System (INIS)

    Windsor, C.G.

    1978-01-01

    It is shown how accelerator based neutron sources, giving a fast neutron pulse of short duration compared to the neutron moderation time, promise to open up a new field of epithermal neutron scattering. The three principal methods of fast neutron production: electrons, protons and fission boosters will be compared. Pulsed reactors are less suitable for epithermal neutrons and will only be briefly mentioned. The design principle of the target producing fast neutrons, the moderator and reflector to slow them down to epithermal energies, and the cell with its beam tubes and shielding will all be described with examples taken from the new Harwell electron linac to be commissioned in 1978. A general comparison of pulsed neutron performance with reactors is fraught with difficulties but has been attempted. Calculation of the new pulsed source fluxes and pulse widths is now being performed but we have taken the practical course of basing all comparisons on extrapolations from measurements on the old 1958 Harwell electron linac. Comparisons for time-of-flight and crystal monochromator experiments show reactors to be at their best at long wavelengths, at coarse resolution, and for experiments needing a specific incident wavelength. Even existing pulsed sources are shown to compete with the high flux reactors in experiments where the hot neutron flux and the time-of-flight methods can be best exploited. The sources under construction can open a new field of inelastic neutron scattering based on energy transfer up to an electron volt and beyond

  12. Polarized epithermal neutron spectrometer at KENS

    International Nuclear Information System (INIS)

    Kohgi, M.

    1983-01-01

    A spectrometer employing a white, epithermal, polarized neutron beam is under construction at KENS. The neutron polarization is achieved by passage through a dynamically polarized proton filter (DPPF). The results of the test experiments show that the DPPF method is promising in obtaining polarized epithermal neutron beam. The basic design of the spectrometer is described

  13. Measurement of thermal, epithermal and fast neutrons fluxes by the activation foil method at IEA-R1 reactor

    International Nuclear Information System (INIS)

    Dias, M.S.; Koskinas, M.F.; Berretta, J.R.; Fratin, L.; Botelho, S.

    1990-01-01

    The thermal, epithermal and fast neutron fluxes have been determined experimentally by the activation foil method at position GI, located near the IEA-R1 reactor core. The reactions used were 197 Au (n,gamma) 198 Au, for thermal and epithermal neutrons and 27 Na (n,alpha) 24 Na, for fast neutrons. The activities were measured by the 4π(PC)β-γ coincidence method. (author)

  14. Epithermal neutron flux characterization of the TRIGA Mark III reactor, Salazar, Mexico, for use in Internal Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Diaz Rizo, O.; Herrera Peraza, E.

    1996-01-01

    The non ideality of the epithermal neutron flux distribution at a reactor site parameter (made, using Chloramine-T method. Radiochemical purity and stability of the labelled product were determined by radiochromatography. The labelled Melagenine-II showed two radioactive fractions thermal-to-epithermal neutron ratio (f) were determined in the 3 typical irradiations positions of the TRIGA Mark III reactor of the National Nuclear Research Institute, Salazar, Mexico, using the Cd-ratio for multi monitor and bare bi-isotopic monitor methods respectively. This characterization is of use in the K o - method of neutron activation analysis, recently introduced at the Institute

  15. Mechanical design of epithermal neutron diagnostic for TFTR

    International Nuclear Information System (INIS)

    Groo, R.C.

    1981-01-01

    The mechanical design of the Epithermal Neutron Diagnostic for TFTR is described. This fission detector system measures the time resolution of the neutron flux for folding into the Neutron Activation system and also provides continuous, wide range coverage of all expected fusion reaction rates

  16. Fast and epithermal neutron radiography using neutron irradiator

    International Nuclear Information System (INIS)

    Oliveira, Karol A.M. de; Crispim, Verginia R.; Ferreira, Francisco J.O.

    2013-01-01

    The neutron radiography technique (NR) with neutrons in the energy range fast to epithermal is a powerful tool used in no-destructive inspection of bulky objects of diverse materials, including those rich in hydrogen, oxygen, nitrogen ad carbon. Thus, it can be used to identify, inclusions, voids and thickness differences in materials such as explosive artifacts and narcotics. Aiming at using NR with fast and epithermal neutrons, an Irradiator was constructed by: a 241 Am-Be source, with 5 Ci activity, a collimator with adjustable collimation rate, L/D; and a shield device composed by plates of borated paraffin and iron. The test specimens chosen were a Beam Purity Indicator (BPI) and an Indicator of Visual Resolution (IVR). The neutron radiography images obtained had a resolution of 444.4 μm and 363.6 μm respectively when registered in: 1) the sheet of the nuclear track solid detector, CR-39 type, through X (n,p) Y nuclear reaction; and 2) Kodak Industrex M radiographic film plate in close contact with a boron converter screen, both stored in a Kodak radiographic cassette. (author)

  17. Design of filtered epithermal neutron beams for BNC

    International Nuclear Information System (INIS)

    Greenwood, R.C.

    1986-01-01

    The design principles of filters (installed in nuclear reactors) to provide epithermal neutron beams suitable for use in 10 B Neutron Capture Therapy (BNCT) are reviewed. The goal of such filters is to provide epithermal neutron beams within an energy range of 1 keV to 30 keV with fluxes in excess of 5 x 10 8 neutrons/cm 2 .s, and having acceptably low contaminant fast neutron (> 30 keV) and gamma components. Filters considered for this application include 238 U, Sc, Fe/Al and Al/S. It is shown that in order to achieve a goal epithermal neutron flux of > 5 x 10 8 neutrons/cm 2 .s, such filters must be located in radial beam channels which view essentially the complete reactor core. Based on considerations of estimated epithermal fluxes, cost and availability of materials, and transmitted neutron energy spectrum, it is suggested that a filter consisting of elements of Al, S, Ti and V might prove to be an optimum design for BNCT applications. 13 references, 3 figures, 8 tables

  18. Method and apparatus for epithermal neutron porosity well logging

    International Nuclear Information System (INIS)

    Hertzog, R.C.; Loomis, W.A.; Wraight, P.

    1991-01-01

    This patent describes a method for investigating the porosity of a subsurface earth formation surrounding a borehole. It comprises repetitively irradiating the borehole and earth formation with discrete bursts of high energy neutrons from a neutron source, which neutrons interact with nuclei of the materials in the borehole and the formation to produce therein populations of epithermal neutrons; detecting the populations of epithermal neutrons at near and far locations in the borehole spaced apart longitudinally by different distances from the neutron source; generating count signals indicative of the magnitudes of the detected epithermal neutron populations at the respective near and far locations; detecting the decay of the epithermal neutron populations following the neutron bursts at least at one location in the borehole and generating signals representative thereof; deriving from the decay signals a signal indicative of the slowing down time of epithermal neutrons in the formation of the at least one location; and deriving from the near and far count signals and the slowing down time signal a measurement signal representative of the porosity of the formation surrounding the borehole inherently compensated for the effects of tool standoff on the responses of the logging tool

  19. Temperature imaging using epithermal neutrons

    International Nuclear Information System (INIS)

    Fowler, P.H.; Taylor, A.D.

    1987-08-01

    The paper concerns the temperature measurement of suitable targets, both remotely and non-invasively, using epithermal neutrons. The text was presented at the Neutron Resonance Radiography Workshop, Los Alamos, U.S.A., 1987. The technique is demonstrated for tantalum foils at different temperatures, using a pulsed beam of epithermal neutrons, at both Los Alamos and ISIS (United Kingdom). Results on the measured time-of-flight spectra and the tantalum resonances are presented. Beam properties and fluxes at ISIS are discussed. Features of the proposed detectors suitable for the temperature technique are outlined, along with the data analysis, the moving targets, the cyclic temperature variations and transients, and the usefulness of the technique. (U.K.)

  20. Measurement of epithermal neutrons by a coherent demodulation technique

    CERN Document Server

    Horiuchi, N; Takahashi, H; Kobayashi, H; Harasawa, S

    2000-01-01

    Epithermal neutrons have been measured using a neutron dosimeter via a coherent demodulation technique. This dosimeter consists of CsI(Tl)-photodiode scintillation detectors, four of which are coupled to neutron-gamma converting foils of various sizes. Neutron-gamma converting foils of In, Au and Co materials were used, each of which has a large capture cross section which peaks in the epithermal neutron energy region. The type of foil was selected according to the material properties that best correspond to the energy of the epithermal neutrons to be measured. In addition, the proposed technique was applied using Au-foils in order to measure the Cd ratio. The validity of the proposed technique was examined using an sup 2 sup 4 sup 1 Am-Be source placed in a testing stack of polyethylene blocks, and the results were compared with the theoretical values calculated by the Monte Carlo calculation. Finally, the dosimeter was applied for measuring epithermal neutrons and the Cd ratio in an experimental beam-tube o...

  1. Optimization in Activation Analysis by Means of Epithermal Neutrons. Determination of Molybdenum in Steel

    Energy Technology Data Exchange (ETDEWEB)

    Brune, D; Jirlow, J

    1963-12-15

    Optimization in activation analysis by means of selective activation with epithermal neutrons is discussed. This method was applied to the determination of molybdenum in a steel alloy without recourse to radiochemical separations. The sensitivity for this determination is estimated to be 10 ppm. With the common form of activation by means of thermal neutrons, the sensitivity would be about one-tenth of this. The sensitivity estimations are based on evaluation of the photo peak ratios of Mo-99/Fe-59.

  2. Polarized Epithermal Neutron Studies of Magnetic Domains

    International Nuclear Information System (INIS)

    Alfimenkov, V.P.; Chernikov, A.N.; Lason, L.; Mareev, Yu. D.; Novitsky, V.V.; Pikelner, L.B.; Skoy, V.R.; Tsulaya, M.I.; Gould, C.R.; Haase, D.G.; Roberson, N.R.

    1997-01-01

    The average size and shape of magnetic domains in a material can be determined from the precession of polarized neutrons traversing the material. Epithermal neutrons (0.5eV< En<100eV), which process more slowly than thermals, effectively probe the internal structure of samples that are thick or have large domains or large internal fields. Such epithermal neutron measurements require a neutron polarizer and analyzer based on cryogenically polarized spin filters. We discuss the measurements at JINR, Dubna, of magnetic domains in a 2.0 cm. diam. crystal of holmium using 1.7 to 59eV neutrons polarized by a dynamically polarized proton target and analyzed with a statically polarized dysprosium target

  3. Investigations on the comparator technique used in epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Bereznai, T.; Bodizs, D.; Keoemley, G.

    1977-01-01

    The possible extension of the comparator technique of reactor neutron activation analysis into the field of epithermal neutron activation has been investigated. Ruthenium was used for multi-isotopic comparator. Experiments show that conversion of the so-called reference k-factors - determined by irradiation with reactor neutrons - into ksup(epi)-factors usable at activation under cadmium filter, can be evaluated with fair accuracy. Sources and extent of errors and their contribution to the final error of analysis are discussed. For equal irradiation and counting times advantage of ENAA for several elements is obvious: the much lower background activity permitted the sample to be measured closer to the detector, under better geometry conditions, consequently, permitting several elements to be determined quantitatively. The number of elements determined and the sensitivity of the method are much dependent on the experimental conditions, especially on the composition of the sample, on the PHIsub(e) value, the irradiation time and the efficiency of the Ge(Li) detector. (T.G.)

  4. Polarized epithermal neutron studies of magnetic domains

    International Nuclear Information System (INIS)

    Alfimenkov, V.P.; Chernikov, A.N.; Lason, L.; Mareev, Y.D.; Novitsky, V.V.; Pikelner, L.B.; Skoy, V.R.; Tsulaya, M.I.; Gould, C.R.; Haase, D.G.; the Triangle Universities Nuclear Laboratory, Durham, North Carolina; Roberson, N.R.; the Triangle Universities Nuclear Laboratory, Durham, North Carolina

    1997-01-01

    The average size and shape of magnetic domains in a material can be determined from the precession of polarized neutrons traversing the material. Epithermal neutrons (0.5eV n <100eV), which precess more slowly than thermals, effectively probe the internal structure of samples that are thick or have large domains or large internal fields. Such epithermal neutron measurements require a neutron polarizer and analyzer based on cryogenically polarized spin filters. We discuss the measurement at JINR, Dubna, of magnetic domains in a 2.0 cm. diam. crystal of holmium using 1.7 to 59 eV neutrons polarized by a dynamically polarized proton target and analyzed with a statically polarized dysprosium target. copyright 1997 American Institute of Physics

  5. Upgrades of the epithermal neutron beam at the Brookhaven Medical Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hungyuan B.; Brugger, R.M.; Rorer, D.C.

    1994-12-31

    The first epithermal neutron beam at the Brookhaven Medical Research Reactor (BMRR) was installed in 1988 and produced a neutron beam that was satisfactory for the development of NCT with epithermal neutrons. This beam was used routinely until 1992 when the beam was upgraded by rearranging fuel elements in the reactor core to achieve a 50% increase in usable flux. Next, after computer modeling studies, it was proposed that the Al and Al{sub 2}O{sub 3} moderator material in the shutter that produced the epithermal neutrons could be rearranged to enhance the beam further. However, this modification was not started because a better option appeared, namely to use fission plates to move the source of fission neutrons closer to the moderator and the patient irradiation position to achieve more efficient moderation and production of epithermal neutrons. A fission plate converter (FPC) source has been designed recently and, to test the concept, implementation of this upgrade has started. The predicted beam parameters will be 12 x 10{sup 9} n{sub epi}/cm{sup 2}sec accompanying with doses from fast neutrons and gamma rays per epithermal neutron of 2.8 x 10{sup -11} and < 1 x 10{sup -11} cGycm{sup 2}/n, respectively, and a current-to-flux ratio of epithermal neutrons of 0.78. This conversion could be completed by late 1996.

  6. Design of a permanent Cd-shielded epithermal neutron irradiation site in the Syrian Miniature Neutron Source Reactor

    International Nuclear Information System (INIS)

    Khattab, K.; Haddad, Kh.; Haj-Hassan, H.

    2008-01-01

    A Cd-shield (cylindrical shell 1 mm in thickness, 34 mm in diameter and 180 mm in length) was used to design a permanent epithermal neutron irradiation site for epithermal neutron activation analysis (ENAA) in the Syrian Miniature Neutron Source Reactor (MNSR). This site was achieved by shielding the surface of the aluminum tube of one of the outer irradiation sites. The calculated depression ratio of thermal neutron flux was 1/10. Homogeneity of the neutron flux in the first outer irradiation site has been found numerically using the WIMSD4 and CITATION codes and experimentally by irradiating five short copper wires using the outer irradiation capsule. Good agreement was obtained between the calculated and the measured results of the neutron flux distributions. (author)

  7. Design of a permanent Cd-shielded epithermal neutron irradiation site in the Syrian Miniature Neutron Source Reactor

    International Nuclear Information System (INIS)

    Khattab, K.; Haddad, Kh.; Haj-Hassan, H.

    2009-01-01

    A Cd-shield (cylindrical shell 1 mm in thickness, 34 mm in diameter and 180 mm in length) was used to design a permanent epithermal neutron irradiation site for epithermal neutron activation analysis (ENAA) in the Syrian Miniature Neutron Source Reactor (MNSR). This site was achieved by shielding the surface of the aluminum tube of one of the outer irradiation sites. The calculated depression ratio of thermal neutron flux was 1/10. Homogeneity of the neutron flux in the first outer irradiation site has been found numerically using the WIMSD4 and CITATION codes and experimentally by irradiating five short copper wires using the outer irradiation capsule. Good agreement was obtained between the calculated and the measured results of the neutron flux distributions. (author)

  8. Earth formation pulsed neutron porosity logging system utilizing epithermal neutron and inelastic scattering gamma ray detectors

    International Nuclear Information System (INIS)

    Smith, H.D. Jr.; Smith, M.P.; Schultz, W.E.

    1978-01-01

    An improved pulsed neutron porosity logging system is provided in the present invention. A logging tool provided with a 14 MeV pulsed neutron source, an epithermal neutron detector and an inelastic scattering gamma ray detector is moved through a borehole. The detection of inelastic gamma rays provides a measure of the fast neutron population in the vicinity of the detector. repetitive bursts of neutrons irradiate the earth formation and, during the busts, inelastic gamma rays representative of the fast neutron population is sampled. During the interval between bursts the epithermal neutron population is sampled along with background gamma radiation due to lingering thermal neutrons. the fast and epithermal neutron population measurements are combined to provide a measurement of formation porosity

  9. The epithermal neutron-flux distribution in the reactor RA - Vinca

    International Nuclear Information System (INIS)

    Marinkov, V.; Bikit, I.; Martinc, R.; Veskovic, M.; Slivka, J.; Vaderna, S.

    1987-01-01

    The distribution of the epithermal neutron flux in the reactor RA - Vinca has been measured by means of Zr - activation detectors. In the channel VK-8 non-homogeneous flux distribution was observed (author) [sr

  10. Utilization of epithermal neutrons for the determination of molybdenum in the presence of uranium

    International Nuclear Information System (INIS)

    Oliveira Melo, M.A.M. de.

    1984-05-01

    Activation analysis by means of selective activation with epithermal neutrons is proposed for the determination of molybdenum in samples when uranium is present. Instrumental activation analysis with epithermal neutrons is advantageous for the determination of elements with large resonance integral, as compared to its thermal neutron activation cross section. The main reason for using this method is the serious interference caused by 99 Mo produced by fission of 235 U. This effect is strongly reduced by using the epicadmium irradiation technique. The filter efficiency has been investigated by irradiation experiments with bare and cadmium-covered samples. A solvent extraction process for uranium, before irradiation, is proposed to reduce sample background. The determination of Mo in leach samples is proposed in order to support the analytical needs of Figueira and Pocos de Caldas Mineral Prospection Programme of Departamento de Tecnologia Mineral from CDTN/NUCLEBRAS (MG,Brazil). The introduction of activation analysis with epithermal neutrons as a routine analytical tool in CDTN is our main goal. This method represents one more opportunity for exploring the analytical facilities available at TRIGA MARK I IPR-R1 nuclear reactor. (Author) [pt

  11. Characteristic analysis on moderating material for obtaining epithermal neutron beam

    International Nuclear Information System (INIS)

    Jiang Xinbiao; Chen Da; Zhang Ying

    2000-01-01

    The one dimension discrete coordinates transport code ANISN was used to calculate three-group constants of 11 elements which could be used to consist moderating epithermal neutron material of beam. Moderating character of simple substances, compounds and mixtures consisted of the optimized elements analyzed three kinds of moderating materials were optimized for epithermal neutron beam

  12. Epithermal neutron beam adoption for lung and pancreatic cancer treatment by boron neutron capture therapy

    International Nuclear Information System (INIS)

    Matsumoto, Tetsuo; Fukushima, Yuji

    2001-01-01

    The depth-dose distributions were evaluated for possible treatment of both lung and pancreatic cancers using an epithermal neutron beam. The Monte Carlo Neutron Photon (MCNP) calculations showed that physical dose in tumors were 6 and 7 Gy/h, respectively, for lung and pancreas, attaining an epithermal neutron flux of 5 x 10 8 ncm -2 s -1 . The boron concentrations were assumed at 100 ppm and 30 ppm, respectively, for lung and pancreas tumors and normal tissues contains 1/10 tumor concentrations. The dose ratios of tumor to normal tissue were 2.5 and 2.4, respectively, for lung and pancreas. The dose evaluation suggests that BNCT using an epithermal neutron beam could be applied for both lung and pancreatic cancer treatment. (author)

  13. A new position-sensitive transmission detector for epithermal neutron imaging

    International Nuclear Information System (INIS)

    Schooneveld, E M; Kockelmann, W; Rhodes, N; Tardocchi, M; Gorini, G; Perelli Cippo, E; Nakamura, T; Postma, H; Schillebeeckx, P

    2009-01-01

    A new neutron resonant transmission (NRT) detector for epithermal neutron imaging has been designed and built for the ANCIENT CHARM project, which is developing a set of complementary neutron imaging methods for analysis of cultural heritage objects. One of the techniques being exploited is NRT with the aim of performing bulk elemental analysis. The 16-pixel prototype NRT detector consists of independent crystals of 2 x 2 mm pixel size, which allow for 2D position-sensitive transmission measurements with epithermal neutrons. First results obtained at the ISIS pulsed spallation neutron source are presented. (fast track communication)

  14. Physics of epi-thermal boron neutron capture therapy (epi-thermal BNCT).

    Science.gov (United States)

    Seki, Ryoichi; Wakisaka, Yushi; Morimoto, Nami; Takashina, Masaaki; Koizumi, Masahiko; Toki, Hiroshi; Fukuda, Mitsuhiro

    2017-12-01

    The physics of epi-thermal neutrons in the human body is discussed in the effort to clarify the nature of the unique radiologic properties of boron neutron capture therapy (BNCT). This discussion leads to the computational method of Monte Carlo simulation in BNCT. The method is discussed through two examples based on model phantoms. The physics is kept at an introductory level in the discussion in this tutorial review.

  15. Use of boron nitride for neutron spectrum characterization and cross-section validation in the epithermal range through integral activation measurements

    Science.gov (United States)

    Radulović, Vladimir; Trkov, Andrej; Jaćimović, Radojko; Gregoire, Gilles; Destouches, Christophe

    2016-12-01

    A recent experimental irradiation and measurement campaign using containers made from boron nitride (BN) at the Jožef Stefan Institute (JSI) TRIGA Mark II reactor in Ljubljana, Slovenia, has shown the applicability of BN for neutron spectrum characterization and cross-section validation in the epithermal range through integral activation measurements. The first part of the paper focuses on the determination of the transmission function of a BN container through Monte Carlo calculations and experimental measurements. The second part presents the process of tayloring the sensitivity of integral activation measurements to specific needs and a selection of suitable radiative capture reactions for neutron spectrum characterization in the epithermal range. A BN container used in our experiments and its qualitative effect on the neutron spectrum in the irradiation position employed is displayed in the Graphical abstract.

  16. Development of resonant detectors for epithermal neutron spectroscopy at pulsed neutron sources

    International Nuclear Information System (INIS)

    Tardocchi, M.; Pietropaolo, A.; Senesi, R.; Andreani, C.; Gorini, G.

    2004-01-01

    New perspectives for epithermal neutron spectroscopy are opened by the development of new detectors for inverse geometry time of flight spectrometers at pulsed neutron sources. One example is the Very Low Angle Detector (VLAD) bank planned to be delivered, within the next 4 years, within the eVERDI project, on the neutron spectrometer VESUVIO, at the ISIS pulsed neutron source (UK). VLAD will extend the (q,ω) kinematical region for neutron scattering to low wavefactor transfer (q -1 ) still keeping energy transfer >1 eV, thus allowing the investigations of new experimental studies in condensed matter systems. The technique being developed for detection of epithermal neutrons, within this low q and high-energy transfer region, is the Resonance Detection Technique. In this work, the state of the detector development will be presented with special focus on the results obtained with some prototype detectors, namely YAP scintillators and cadmium-zinc-telluride semiconductors

  17. Epithermal neutron activation analysis for studying the environment

    International Nuclear Information System (INIS)

    Frontas'eva, M.V.; Steinnes, E.

    1997-01-01

    Epithermal neutron activation analysis (ENAA) has certain advantages over the conventional instrumental analysis (INAA) in terms of improvement in precision and lowering of detection limits, reduction of high matrix activity and fission interferences if any. The current status and the applications of ENAA to environmental samples are reviewed. Experience in the use of ENAA in the monitoring of atmospheric depositions by means of moss-biomonitors at pulsed fast reactor IBR-2 in Dubna is summarized. INAA has shown to be useful for a number of sample types of interest in environmental studies, and should find more extensive use in this area. Analysis of airborne particulate matter is a case where ENAA should be particularly useful. A similar case where ENAA has shown strong performance is in the analysis of mosses used as biomonitors of atmospheric deposition, where 45 elements were determined. In this and other cases, however, induction-coupled plasma mass spectrometry is a very strong competitor, offering data for even more elements. A comparison of ENAA and ICP-MS for moss analysis is presented, and cases where ENAA is unique are discussed

  18. Neutron kinetics in moderators and SNM detection through epithermal-neutron-induced fissions

    Energy Technology Data Exchange (ETDEWEB)

    Gozani, Tsahi, E-mail: tgmaven@gmail.com [1050 Harriet St., Palo Alto, CA 94301 (United States); King, Michael J. [Rapiscan Laboratories Inc., 520 Almanor Ave., Sunnyvale, CA 94085 (United States)

    2016-01-01

    Extension of the well-established Differential Die Away Analysis (DDAA) into a faster time domain, where more penetrating epithermal neutrons induce fissions, is proposed and demonstrated via simulations and experiments. In the proposed method the fissions stimulated by thermal, epithermal and even higher-energy neutrons are measured after injection of a narrow pulse of high-energy 14 MeV (d,T) or 2.5 MeV (d,D) source neutrons, appropriately moderated. The ability to measure these fissions stems from the inherent correlation of neutron energy and time (“E–T” correlation) during the process of slowing down of high-energy source neutrons in common moderating materials such as hydrogenous compounds (e.g., polyethylene), heavy water, beryllium and graphite. The kinetic behavior following injection of a delta-function-shaped pulse (in time) of 14 MeV neutrons into such moderators is studied employing MCNPX simulations and, when applicable, some simple “one-group” models. These calculations served as a guide for the design of a source moderator which was used in experiments. Qualitative relationships between slowing-down time after the pulse and the prevailing neutron energy are discussed. A laboratory system consisting of a 14 MeV neutron generator, a polyethylene-reflected Be moderator, a liquid scintillator with pulse-shape discrimination (PSD) and a two-parameter E–T data acquisition system was set up to measure prompt neutron and delayed gamma-ray fission signatures in a 19.5% enriched LEU sample. The measured time behavior of thermal and epithermal neutron fission signals agreed well with the detailed simulations. The laboratory system can readily be redesigned and deployed as a mobile inspection system for SNM in, e.g., cars and vans. A strong pulsed neutron generator with narrow pulse (<75 ns) at a reasonably high pulse frequency could make the high-energy neutron induced fission modality a realizable SNM detection technique.

  19. Determination of selenium in Ni + Co concentrates applying epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Perez Sayaz, G.; Hernandez Rivero, A.; Moreno Bermudez, J.; Ribeiro Guevara, S.; Arribere, M.A.; Molina Insfran, J.

    1996-01-01

    Concentration of Se in Ni + Co concentrates obtained in nickel industry has to be determined as that is a quality control requirement for its commercialization. At present, analysis of Se, specially at a minor and trace levels is relatively complicated and destructive procedures are frequently required. In this work determination of Se by epithermal neutron activation analysis (ENAA) in 17 samples of nickel industry was investigated. Application of ENAA allowed nondestructive determination of Se concentration down to ppm level in spite of presence of high Co, Fe, Ni, and Cr contents in the samples

  20. Determination of 30 elements in coal and fly ash by thermal and epithermal neutron-activation analysis

    International Nuclear Information System (INIS)

    Rowe, J.J.; Steinnes, E.

    1977-01-01

    Thirty elements are determined in coal and fly ash by instrumental neutron-activation analysis using both thermal and epithermal irradiation. Gamma-ray spectra were recorded 7 and 20 days after the irradiations. The procedure is applicable to the routine analysis of coals and fly ash. Epithermal irradiation was found preferable for the determination of Ni, Zn, As, Se, Br, Rb, Sr, Mo, Sb, Cs, Ba, Sm, Tb, Hf, Ta, W, Th and U, whereas thermal irradiation was best for Sc, Cr, Fe, Co, La, Ce, Nd, Eu, Yb and Lu. Results for SRM 1632 (coal) and SRM 1633 (fly ash) agree with those of other investigators. (author)

  1. Bromine and iodine in Chinese medical herbs determined via epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Chien-Yi Chen; Yuan-Yaw Wei; Sheng-Pin ChangLai; Lung-Kwang Pan

    2003-01-01

    Nineteen natural herbs and two prescriptions prepared from mixed herbs were analyzed via epithermal neutron activation analysis (ENAA) to evaluate their bromine and iodine concentration. Traditional medical doctors prescribed the samples presented in this work to most Taiwanese children for strengthening their immune systems. Empirical results indicated a wide diversity of bromine in the samples. Yet, the iodine concentration was only around one to tenth or twentieth of the bromine. The maximum daily intake (MDI) for various medical herbs was also widely diversified from one to tenfold on the basis of various criteria. The minimum detectable concentration (MDC) of bromine and iodine found was 0.42±0.14 ppm and 0.067±0.016 ppm, respectively. Compared to that from conventional thermal neutron activation analysis (NAA) for a similar evaluation, the extremely low MDC obtained here was attributed to the large amount of thermal neutron absorption during sample irradiation. (author)

  2. Measurement of the neutron flux distributions, epithermal index, Westcott thermal neutron flux in the irradiation capsules of hydraulic conveyer (Hyd) and pneumatic tubes (Pn) facilities of the KUR

    International Nuclear Information System (INIS)

    Chatani, Hiroshi

    2001-05-01

    The reactions of Au(n, γ) 198 Au and Ti(n, p) 47 or 48 Sc were used for the measurements of the thermal and epithermal (thermal + epithermal) and the fast neutron flux distributions, respectively. In the case of Hyd (Hydraulic conveyer), the thermal + epithermal and fast neutron flux distributions in the horizontal direction in the capsule are especially flat; the distortion of the fluxes are 0.6% and 5.4%, respectively. However, these neutron fluxes in the vertical direction are low at the top and high at the bottom of the capsule. These differences between the top and bottom are 14% for both distributions. On the other hand, in polyethylene capsules of Pn-1, 2, 3 (Pneumatic tubes Nos. 1, 2, 3), in contrast with Hyd, these neutron flux distributions in the horizontal direction have gradients of 8 - 18% per 2.5 cm diameter, and those on the vertical axis have a distortion of approximately 5%. The strength of the epithermal dE/E component relative to the neutron density including both thermal and epithermal neutrons, i.e., the epithermal index, for the hydraulic conveyer (Hyd) and pneumatic tube No.2 (Pn-2), in which the irradiation experiments can be achieved, are determined by the multiple foil activation method using the reactions of Au(n, γ) 198 Au and Co(n, γ) 60(m+g) Co. The epithermal index observed in an aluminum capsule of Hyd is 0.034-0.04, and the Westcott thermal neutron flux is 1.2x10 14 cm -2 sec -1 at approximately 1 cm above the bottom. The epithermal index in a Pn-2 polyethylene capsule was measured by not only the multiple foil activation method but also the Cd-ratio method in which the Au(n, γ) 198 Au reaction in a cadmium cover is also used. The epithermal index is 0.045 - 0.055, and the thermal neutron flux is 1.8x10 13 cm -2 sec -1 . (J.P.N.)

  3. Measurement of thermal, epithermal and fast neutron flux in the IEA-R1 reactor by the foil activation method

    International Nuclear Information System (INIS)

    Koskinas, M.F.

    1979-01-01

    Experimental and theoretical details of the foil activation method applied to neutrons flux measurements at the IEA-R1 reactor are presented. The thermal - and epithermal - neutron flux were determined form activation measurements of gold, cobalt and manganese foils; and for the fast neutron flux determination, aluminum, iron and nickel foils were used. The measurements of the activity induced in the metal foils were performed using a Ge-Li gamma spectrometry system. In each energy range of the reactor neutron spectrum, the agreement among the experimental flux values obtained using the three kind of materials, indicates the consistency of the theoretical approach and of the nuclear parameters selected. (Author) [pt

  4. Use of boron nitride for neutron spectrum characterization and cross-section validation in the epithermal range through integral activation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Radulović, Vladimir, E-mail: vladimir.radulovic@ijs.si [Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); Trkov, Andrej [Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); IAEA, Vienna International Centre, PO Box 100, A-1400 Vienna (Austria); Jaćimović, Radojko [Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); Gregoire, Gilles; Destouches, Christophe [CEA, DEN, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St. Paul-Lez-Durance (France)

    2016-12-21

    A recent experimental irradiation and measurement campaign using containers made from boron nitride (BN) at the Jožef Stefan Institute (JSI) TRIGA Mark II reactor in Ljubljana, Slovenia, has shown the applicability of BN for neutron spectrum characterization and cross-section validation in the epithermal range through integral activation measurements. The first part of the paper focuses on the determination of the transmission function of a BN container through Monte Carlo calculations and experimental measurements. The second part presents the process of tayloring the sensitivity of integral activation measurements to specific needs and a selection of suitable radiative capture reactions for neutron spectrum characterization in the epithermal range. A BN container used in our experiments and its qualitative effect on the neutron spectrum in the irradiation position employed is displayed in the Graphical abstract. - Graphical abstract: Neutron spectra inside the JSI TRIGA Mark II PT irradiation position, obtained with a Monte Carlo calculation: blue: unperturbed, green inside a BN container, of wall thickness 4 mm, 13 mm in diameter and 14 mm in height.

  5. Use of boron nitride for neutron spectrum characterization and cross-section validation in the epithermal range through integral activation measurements

    International Nuclear Information System (INIS)

    Radulović, Vladimir; Trkov, Andrej; Jaćimović, Radojko; Gregoire, Gilles; Destouches, Christophe

    2016-01-01

    A recent experimental irradiation and measurement campaign using containers made from boron nitride (BN) at the Jožef Stefan Institute (JSI) TRIGA Mark II reactor in Ljubljana, Slovenia, has shown the applicability of BN for neutron spectrum characterization and cross-section validation in the epithermal range through integral activation measurements. The first part of the paper focuses on the determination of the transmission function of a BN container through Monte Carlo calculations and experimental measurements. The second part presents the process of tayloring the sensitivity of integral activation measurements to specific needs and a selection of suitable radiative capture reactions for neutron spectrum characterization in the epithermal range. A BN container used in our experiments and its qualitative effect on the neutron spectrum in the irradiation position employed is displayed in the Graphical abstract. - Graphical abstract: Neutron spectra inside the JSI TRIGA Mark II PT irradiation position, obtained with a Monte Carlo calculation: blue: unperturbed, green inside a BN container, of wall thickness 4 mm, 13 mm in diameter and 14 mm in height.

  6. Measurement of trace cadmium and elements in bone by epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Dowlati, R.; Jervis, R.E.

    1991-01-01

    Epithermal neutron activation analysis (ENAA) was applied to measure quantitatively Cd and other elements in bone samples from control and Cd-fed rats. This method was found to be non-destructive to the bone samples, with no sign of 'radiolytic charring' and was sensitive enough to detect and quantify Cd in bone samples at normal levels for mammals (viz. 0.5-1.0 μg/g) and higher. Two different thermal neutron shield materials were utilized, namely cadmium and boron. The boron shield resulted in a 27% improvement in the detection limit of Cd in bone. The accuracy of ENAA for Cd was assessed by intercomparison with electrothermal atomic absorption spectrophotometry (ETAAS), and the results in fair agreement (±23%) with those from ENAA

  7. Optimization study for an epithermal neutron beam for boron neutron capture therapy at the University of Virginia Research Reactor

    International Nuclear Information System (INIS)

    Burns, T.D. Jr.

    1995-05-01

    The non-surgical brain cancer treatment modality, Boron Neutron Capture Therapy (BNCT), requires the use of an epithermal neutron beam. This purpose of this thesis was to design an epithermal neutron beam at the University of Virginia Research Reactor (UVAR) suitable for BNCT applications. A suitable epithermal neutron beam for BNCT must have minimal fast neutron and gamma radiation contamination, and yet retain an appreciable intensity. The low power of the UVAR core makes reaching a balance between beam quality and intensity a very challenging design endeavor. The MCNP monte carlo neutron transport code was used to develop an equivalent core radiation source, and to perform the subsequent neutron transport calculations necessary for beam model analysis and development. The code accuracy was validated by benchmarking output against experimental criticality measurements. An epithermal beam was designed for the UVAR, with performance characteristics comparable to beams at facilities with cores of higher power. The epithermal neutron intensity of this beam is 2.2 x 10 8 n/cm 2 · s. The fast neutron and gamma radiation KERMA factors are 10 x 10 -11 cGy·cm 2 /n epi and 20 x 10 -11 cGy·cm 2 /n epi , respectively, and the current-to-flux ratio is 0.85. This thesis has shown that the UVAR has the capability to provide BNCT treatments, however the performance characteristics of the final beam of this study were limited by the low core power

  8. Errors of absolute methods of reactor neutron activation analysis caused by non-1/E epithermal neutron spectra

    International Nuclear Information System (INIS)

    Erdtmann, G.

    1993-08-01

    A sufficiently accurate characterization of the neutron flux and spectrum, i.e. the determination of the thermal flux, the flux ratio and the epithermal flux spectrum shape factor, α, is a prerequisite for all types of absolute and monostandard methods of reactor neutron activation analysis. A convenient method for these measurements is the bare triple monitor method. However, the results of this method, are very imprecise, because there are high error propagation factors form the counting errors of the monitor activities. Procedures are described to calculate the errors of the flux parameters, the α-dependent cross-section ratios, and of the analytical results from the errors of the activities of the monitor isotopes. They are included in FORTRAN programs which also allow a graphical representation of the results. A great number of examples were calculated for ten different irradiation facilities in four reactors and for 28 elements. Plots of the results are presented and discussed. (orig./HP) [de

  9. MCNP study for epithermal neutron irradiation of an isolated liver at the Finnish BNCT facility.

    Science.gov (United States)

    Kotiluoto, P; Auterinen, I

    2004-11-01

    A successful boron neutron capture treatment (BNCT) of a patient with multiple liver metastases has been first given in Italy, by placing the removed organ into the thermal neutron column of the Triga research reactor of the University of Pavia. In Finland, FiR 1 Triga reactor with an epithermal neutron beam well suited for BNCT has been extensively used to irradiate patients with brain tumors such as glioblastoma and recently also head and neck tumors. In this work we have studied by MCNP Monte Carlo simulations, whether it would be beneficial to treat an isolated liver with epithermal neutrons instead of thermal ones. The results show, that the epithermal field penetrates deeper into the liver and creates a build-up distribution of the boron dose. Our results strongly encourage further studying of irradiation arrangement of an isolated liver with epithermal neutron fields.

  10. Experimental demonstration of a compact epithermal neutron source based on a high power laser

    Science.gov (United States)

    Mirfayzi, S. R.; Alejo, A.; Ahmed, H.; Raspino, D.; Ansell, S.; Wilson, L. A.; Armstrong, C.; Butler, N. M. H.; Clarke, R. J.; Higginson, A.; Kelleher, J.; Murphy, C. D.; Notley, M.; Rusby, D. R.; Schooneveld, E.; Borghesi, M.; McKenna, P.; Rhodes, N. J.; Neely, D.; Brenner, C. M.; Kar, S.

    2017-07-01

    Epithermal neutrons from pulsed-spallation sources have revolutionised neutron science allowing scientists to acquire new insight into the structure and properties of matter. Here, we demonstrate that laser driven fast (˜MeV) neutrons can be efficiently moderated to epithermal energies with intrinsically short burst durations. In a proof-of-principle experiment using a 100 TW laser, a significant epithermal neutron flux of the order of 105 n/sr/pulse in the energy range of 0.5-300 eV was measured, produced by a compact moderator deployed downstream of the laser-driven fast neutron source. The moderator used in the campaign was specifically designed, by the help of MCNPX simulations, for an efficient and directional moderation of the fast neutron spectrum produced by a laser driven source.

  11. Epithermal neutron activation analysis in applied microbiology

    International Nuclear Information System (INIS)

    Marina Frontasyeva

    2012-01-01

    Some results from applying epithermal neutron activation analysis at FLNP JINR, Dubna, Russia, in medical biotechnology, environmental biotechnology and industrial biotechnology are reviewed. In the biomedical experiments biomass from the blue-green alga Spirulina platensis (S. platensis) has been used as a matrix for the development of pharmaceutical substances containing such essential trace elements as selenium, chromium and iodine. The feasibility of target-oriented introduction of these elements into S. platensis biocomplexes retaining its protein composition and natural beneficial properties was shown. The absorption of mercury on growth dynamics of S. platensis and other bacterial strains was observed. Detoxification of Cr and Hg by Arthrobacter globiformis 151B was demonstrated. Microbial synthesis of technologically important silver nanoparticles by the novel actinomycete strain Streptomyces glaucus 71 MD and blue-green alga S. platensis were characterized by a combined use of transmission electron microscopy, scanning electron microscopy and energy-dispersive analysis of X-rays. It was established that the tested actinomycete S. glaucus 71 MD produces silver nanoparticles extracellularly when acted upon by the silver nitrate solution, which offers a great advantage over an intracellular process of synthesis from the point of view of applications. The synthesis of silver nanoparticles by S. platensis proceeded differently under the short-term and long-term silver action. (author)

  12. Epithermal Neutron Activation Analysis of the Asian Herbal Plants

    International Nuclear Information System (INIS)

    Baljinnyam, N.; Frontasyeva, M. V.; Ostrovnaya, T. M.; Pavlov, S. S.; Jugder, B.; Norov, N.

    2011-01-01

    Asian medicinal herbs Chrysanthemum (Spiraea aquilegifolia Pall.) and Red Sandalwood (Pterocarpus Santalinus) are widely used in folk and Ayurvedic medicine for healing and preventing some diseases. The modern medical science has proved that the Chrysanthemum (Spiraea aquilegifolia Pall.) possesses the following functions: reducing blood press, dispelling cancer cell, coronary artery's expanding and bacteriostating and Red Sandalwood (Pterocarpus Santalinus) is recommended against headache, toothache, skin diseases, vomiting and sometimes it is taken for treatment of diabetes. Species of Chrysanthemums were collected in the north-eastern and central Mongolia, and the Red Sandalwood powder was imported from India. Samples of Chrysanthemums (branches, flowers and leaves)(0.5 g) and red sandalwood powder (0.5 g) were subjected to the multi-element instrumental neutron activation analysis using epithermal neutrons (ENAA) at the IBR-2 reactor, Frank Laboratory of Neutron Physics (FLNP) JINR, Dubna. A total of 41 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Cr, Mn, Fe, Co, Ni, Zn, As, Se, Br, Rb, Sr, Zr, Mo, Cd, Cs, Ba, La, Hf, Ta, W, Sb, Au, Hg, Ce, Nd, Sm, Eu, Tb, Dy, Yb, Th, U, Lu) were determined. For the first time such a large group of elements was determined in the herbal plants used in Mongolia. The quality control of the analytical results was provided by using certified reference material Bowen Cabbage. The results obtained are compared to the ''Reference plant? data (B. Markert, 1992) and interpreted in terms of excess of such elements as Se, Cr, Ca, Fe, Ni, Mo, and rare earth elements.

  13. An accelerator-based epithermal photoneutron source for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Mitchell, H.E.

    1996-04-01

    Boron neutron capture therapy is an experimental binary cancer radiotherapy modality in which a boronated pharmaceutical that preferentially accumulates in malignant tissue is first administered, followed by exposing the tissue in the treatment volume to a thermal neutron field. Current usable beams are reactor-based but a viable alternative is the production of an epithermal neutron beam from an accelerator. Current literature cites various proposed accelerator-based designs, most of which are based on proton beams with beryllium or lithium targets. This dissertation examines the efficacy of a novel approach to BNCT treatments that incorporates an electron linear accelerator in the production of a photoneutron source. This source may help to resolve some of the present concerns associated with accelerator sources, including that of target cooling. The photoneutron production process is discussed as a possible alternate source of neutrons for eventual BNCT treatments for cancer. A conceptual design to produce epithermal photoneutrons by high photons (due to bremsstrahlung) impinging on deuterium targets is presented along with computational and experimental neutron production data. A clinically acceptable filtered epithermal neutron flux on the order of 10 7 neutrons per second per milliampere of electron current is shown to be obtainable. Additionally, the neutron beam is modified and characterized for BNCT applications by employing two unique moderating materials (an Al/AlF 3 composite and a stacked Al/Teflon design) at various incident electron energies

  14. An accelerator-based epithermal photoneutron source for boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, Hannah E. [Georgia Inst. of Technology, Atlanta, GA (United States)

    1996-04-01

    Boron neutron capture therapy is an experimental binary cancer radiotherapy modality in which a boronated pharmaceutical that preferentially accumulates in malignant tissue is first administered, followed by exposing the tissue in the treatment volume to a thermal neutron field. Current usable beams are reactor-based but a viable alternative is the production of an epithermal neutron beam from an accelerator. Current literature cites various proposed accelerator-based designs, most of which are based on proton beams with beryllium or lithium targets. This dissertation examines the efficacy of a novel approach to BNCT treatments that incorporates an electron linear accelerator in the production of a photoneutron source. This source may help to resolve some of the present concerns associated with accelerator sources, including that of target cooling. The photoneutron production process is discussed as a possible alternate source of neutrons for eventual BNCT treatments for cancer. A conceptual design to produce epithermal photoneutrons by high photons (due to bremsstrahlung) impinging on deuterium targets is presented along with computational and experimental neutron production data. A clinically acceptable filtered epithermal neutron flux on the order of 107 neutrons per second per milliampere of electron current is shown to be obtainable. Additionally, the neutron beam is modified and characterized for BNCT applications by employing two unique moderating materials (an Al/AlF3 composite and a stacked Al/Teflon design) at various incident electron energies.

  15. Study on the determination of uranium by activation analysis with epithermal neutrons

    International Nuclear Information System (INIS)

    Atalla, L.T.

    1977-01-01

    A method is described that is applied to the determination of uranium in different types of materials, either by an entirely instrumental method or with the chemical separation of uranium-239, when the presence of interferences does not allow the instrumental analysis. The advantages and disadvantages in the use of epithermal neutrons in the activation of samples for a more selective activation of uranium-238 also presented. The instrumental method is tested through standart materials, accepted internationally. The possibility of uranium extraction with di-etil-hexilphosphoric acid is also presented and the choice of the former technique is justified. The sensitibility of the method is discussed as well as precision and accuracy through results obtained in the analysis of the standards and the calibration curve of uranium [pt

  16. Determination of trace cadmium and other elements in bone by epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Dowlati, R.; Jervis, R.E.

    1991-01-01

    Epithermal neutron activation analysis (ENAA) was applied to measure quantitatively Cd and other elements in bone samples from control and Cd-fed rats. This method was found to be non-destructive to the bone samples, with no sign of 'radiolytic charring' and was sensitive enough to detect and quantify Cd in bone samples at normal levels for mammals (viz. 0.5-1.0μg/g) and higher. Two different thermal neutron shield materials were utilized, namely cadmium and boron. The boron shield resulted in a 27% improvement in the detection limit of Cd in bone. The accuracy of ENAA for Cd was assessed by intercomparison with electrothermal atomic absorption spectrophotometry (ETAAS), and the results were in fair agreement (±23%) with those from ENAA. (author) 24 refs.; 5 tabs

  17. Uranium in coral skeletons determined by epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Ohde, S.; Hossain, M.M.M.; Ozaki, H.; Masuzawa, T.

    2003-01-01

    A simple and non-destructive method has been proposed for the routine determination of uranium by epithermal neutron activation analysis in coral skeletons. Using a cadmium capsule, about 0.1-0.2 g samples were irradiated for 6 hours in the Triga Mark II Reactor. Measurements of γ-ray ( 239 Np via 239 U) were performed with each sample and standard after cooling for about three days. Compared with a non-destructive thermal NAA, the present method was found to improve the sensitivity because it reduced the intense Compton background induced by 24 Na. Uranium in coral standards was determined within 2% of analytical precision. The data obtained for the carbonate standards are mostly consistent with reported values. The present method could be usefully applied to determine uranium contents in fossil corals from the Funafuti Atoll in the Pacific. The distribution of uranium between seawater and coral skeletons is also discussed in order to understand the environmental media in which the coral grew. (author)

  18. A new position-sensitive detector for thermal and epithermal neutrons

    International Nuclear Information System (INIS)

    Jeavons, A.P.; Ford, N.L.; Lindberg, B.; Sachot, R.

    1977-01-01

    A new two-dimensional position-sensitive neutron detector is described. It is based on (n,γ) neutron resonance capture in a foil with subsequent detection of internal conversion electrons with a high-density proportional chamber. Large-area detectors with a 1 mm spatial resolution are feasible. A detection efficiency of 50% is possible for thermal neutrons using gadolinium-157 foil and for epithermal neutrons using hafnium-177. (Auth.)

  19. Method and apparatus for dual-spaced fast/epithermal neutron porosity measurements

    International Nuclear Information System (INIS)

    Smith, H.D. Jr.

    1986-01-01

    A method is described for determining the porosity of earth formations in the vicinity of a well borehole, comprising: (a) irradiating the earth formations in the vicinity of the well borehole with a continuous chemical type source of fast neutrons, (b) detecting the fast neutron population at a first shorter spaced distance from the neutron source in the borehole and generating signals representative thereof, (c) detecting the epithermal neutron population at a second space distance from the neutron source in the borehole and generating signals representative thereof, the second spaced distance being greater than the first spaced distance from the neutron source, (d) forming a ratio of the signals representing the fast and epithermal neutron populations to derive a measurement signal functionally related to the porosity of the earth formations in the vicinity of the borehole, and (e) calibrating the measurement signal according to a predetermined functional relationship to derive a porosity signal quantitatively representative of the porosity of the earth formations in the vicinity of the borehole

  20. Dependence of the Ratio between the Resonance Integral and Thermal Neutron Cross Section on the Deviation of the Epithermal Neutron Spectrum from the 1/E Law

    International Nuclear Information System (INIS)

    Soliman, N.F.

    2012-01-01

    In k 0 - Neutron Activation Analysis (k 0 -NAA), the conversion from the tabulated Q 0 (ratio of the resonance integral to thermal neutron cross-section)to Q 0 (α) (α is the shape factor of the epithermal neutron flux, indicating the deviation of the epithermal neutron spectrum from the ideal 1/E shape) are calculated using a FORTRAN program. The calculations are done for most elements that can be detected by neutron activation using different values of the parameter (α) ranging from -0.1≤α≤+0.1. The obtained data are used to study the dependence of the values (α) on the irradiation position factor in (k 0 -NAA)equation for some selected isotopes differ in their resonance energy and its Q 0 values. The results show that, the irradiation factor is affective mainly for low thermal tro epithermal flux ratio f especially for Q 0 value greater than 50. so consequently determining the irradiation parameters α value is not needed for irradiation positions that rich with thermal neutron. But for high f values the irradiation position factor should be taken into account. On the other hand the constructed FORTRAN program can be used to calculate the value Q 0 (α) directly for different value of α

  1. Theoretical and experimental study of collectrons for epithermal neutron flux in reactors

    International Nuclear Information System (INIS)

    Agu, M.N.

    1986-01-01

    A theoretical study of nuclear reactions and electric charge displacements arising in sensitivity to thermal and epithermal neutrons in collectrons allowed a computer code conception. Collectrons in Rhodium, Silver, Cobalt, Hafnium, Erbium, Gadolinium and Holmium have been tested in different radiation fields given by neutron or gamma filters irradiated in different places of Melusine and Siloe reactors. Some emitters were covered with different steel, nickel or zircaloy thicknesses. Theoretical and experimental results are consistent; that validate the computer code and show possibilities and necessity of covering collectron emitters to reduce or cancel the gamma sensitivity and to improve response instantaneity. A selective measurement of epithermal neutron flux can by this way, made by associating two types of collectrons [fr

  2. An in-situ check of the epithermal neutron log calibration

    International Nuclear Information System (INIS)

    Burkhard, N.R.

    1993-01-01

    The epithermal neutron log is used to measure the water content of the formation. The large hole epithermal neutron sonde (ENS) utilized at the Nevada Test Site (NTS) has been calibrated in the Hydrogen Content Test Facility (HCTF). These calibrations are used to correct the measured neutron count rate for the effects of tool stand-off and density. For some time, the suspicion has existed that the water contents that are calculated from the ENS data are too large. Hole U2gj represented a unique opportunity to check the validity of the ENS calibration under realistic logging conditions; a portion of the hole had been cemented and redrilled and then logged. The cements have a known water content and can be used as an in-situ calibration check. The author found that the water contents from the log data after processing with the existing calibrations are consistent with these known cement water contents. In addition, the study indicates that the raw neutron data might be more appropriately smoothed by using a median smoother rather than the currently utilized mean smoother

  3. An in-situ check of the epithermal neutron log calibration

    International Nuclear Information System (INIS)

    Burkhard, N.R.

    1993-09-01

    The epithermal neutron log is used to measure the water content of the formation. The large hole epithermal neutron sonde (ENS) that we utilize at the Nevada Test Site (NTS) has been calibrated in the Hydrogen Content Test Facility (HCTF). These calibrations are used to correct the measured neutron count rate for the effects of tool stand-off and density. For sometime, the suspicion has existed that the water contents that are calculated from the ENS data are too large. Hole U2gj represented a unique opportunity to check the validity of the ENS calibration under realistic logging conditions; a portion of the hole had been cemented and re drilled and then logged. The cements have a known water content and can be used as an in situ calibration check. I found that the water contents from the log data after processing with the existing calibrations are consistent with these known cement water contents. In addition, the study indicates that the raw neutron data might be more appropriately smoothed by using a median smoother rather than the currently utilized mean smoother

  4. Detector for imaging and dosimetry of laser-driven epithermal neutrons by alpha conversion

    Science.gov (United States)

    Mirfayzi, S. R.; Alejo, A.; Ahmed, H.; Wilson, L. A.; Ansell, S.; Armstrong, C.; Butler, N. M. H.; Clarke, R. J.; Higginson, A.; Notley, M.; Raspino, D.; Rusby, D. R.; Borghesi, M.; Rhodes, N. J.; McKenna, P.; Neely, D.; Brenner, C. M.; Kar, S.

    2016-10-01

    An epithermal neutron imager based on detecting alpha particles created via boron neutron capture mechanism is discussed. The diagnostic mainly consists of a mm thick Boron Nitride (BN) sheet (as an alpha converter) in contact with a non-borated cellulose nitride film (LR115 type-II) detector. While the BN absorbs the neutrons in the thermal and epithermal ranges, the fast neutrons register insignificantly on the detector due to their low neutron capture and recoil cross-sections. The use of solid-state nuclear track detectors (SSNTD), unlike image plates, micro-channel plates and scintillators, provide safeguard from the x-rays, gamma-rays and electrons. The diagnostic was tested on a proof-of-principle basis, in front of a laser driven source of moderated neutrons, which suggests the potential of using this diagnostic (BN+SSNTD) for dosimetry and imaging applications.

  5. Determination of Uranium and Thorium in Brazilian coals by epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Bernedo, L.F.B.

    1981-08-01

    An experimental technique for the determination of uranium and thorium in coal by epithermal neutron activation was developed and systemized. Seventeen different coal samples, six copper monitors for neutron flux corrections and three NBS standard coal samples were irradiated together in a cadmium cylinder. Uranium and thorium were determined by measuring the 239 N sub(p) and 233 P sub(a) activities respectively, being both produced in (n,γ) reactions and subsequent β - decay. The 239 N sub(p) was measured by counting the 106.4 KeV γ-ray in a LEPS detector and the 233 P sub(a) by counting the 311.8 KeV γ-ray, but in a Ge(Li) detector. A 4096 multichannel analizer and a PDP-11 computer complemented the basic measuring equipment. An average precision of 3% was obtained in the analysis of seventeen coal samples coming from different strata and heights of Charqueadas and Morungava mines in Rio Grande do Sul State. The sensitivity of the method is around 100 ppb. This technique will allow determinations of up to twenty elements, besides uranium and thorium, and it can be applied in routine analysis. (Author) [pt

  6. Advances on detectors for low-angle scattering of epithermal neutrons

    International Nuclear Information System (INIS)

    Perelli Cippo, E; Gorini, G; Tardocchi, M; Andreani, C; Pietropaolo, A; Senesi, R; Rhodes, N J; Schoonveld, E M

    2008-01-01

    The Very Low Angle Detector (VLAD) installed at the ISIS spallation neutron source is a novel instrument for epithermal neutron scattering with a range of applications in solid state physics. VLAD extends the kinematical space of the VESUVIO spectrometer to low momentum transfers at neutron energies above 1 eV. Measurements at scattering angles as low as 1° have been made with limitations due to the achievable signal/background ratio. (technical design note)

  7. Application of epithermal neutron activation in multielement analysis of silicate rocks employing both coaxial Ge(Li) and low energy photon detector systems

    Science.gov (United States)

    Baedecker, P.A.; Rowe, J.J.; Steinnes, E.

    1977-01-01

    The instrumental activation analysis of silicate rocks using epithermal neutrons has been studied using both high resolution coaxial Ge(Li) detectors and low energy photon detectors, and applied to the determination of 23 elements in eight new U.S.G.S. standard rocks. The analytical use X-ray peaks associated with electron capture or internal conversion processes has been evaluated. Of 28 elements which can be considered to be determinable by instrumental means, the epithermal activation approach is capable of giving improved sensitivity and precision in 16 cases, over the normal INAA procedure. In eleven cases the use of the low energy photon detector is thought to show advantages over convertional coaxial Ge(Li) spectroscopy. ?? 1977 Akade??miai Kiado??.

  8. Fission reactor based epithermal neutron irradiation facilities for routine clinical application in BNCT-Hatanaka memorial lecture

    International Nuclear Information System (INIS)

    Harling, Otto K.

    2009-01-01

    Based on experience gained in the recent clinical studies at MIT/Harvard, the desirable characteristics of epithermal neutron irradiation facilities for eventual routine clinical BNCT are suggested. A discussion of two approaches to using fission reactors for epithermal neutron BNCT is provided. This is followed by specific suggestions for the performance and features needed for high throughput clinical BNCT. An example of a current state-of-the-art, reactor based facility, suited for routine clinical use is discussed. Some comments are provided on the current status of reactor versus accelerator based epithermal neutron sources for BNCT. This paper concludes with a summary and a few personal observations on BNCT by the author.

  9. Thermal, epithermal and thermalized neutron attenuation properties of ilmenite-serpentine heat resistant concrete shield

    International Nuclear Information System (INIS)

    Kany, A.M.I.; El-Gohary, M.I.; Kamal, S.M.

    1994-01-01

    Experimental measurements were carried out to study the attenuation properties of low-energy neutrons transmitted through unheated and preheated barriers of heavy-weight, highly hydrated and heat-resistant concrete shields. The concrete shields under investigation have been prepared from naturally occurring ilmenite and serpentine Egyptian ores. A collimated beam obtained from an Am-Be source was used as a source of neutrons, while the measurements of total thermal, epithermal, and thermalized neutron fluxes were performed using a BF-3 detector, multichannel analyzer and Cd filter. Results show that the ilmenite-serpentine concrete proved to be a better thermal, epithermal and thermalized neutron attenuator than the ordinary concrete especially at a high temperature of concrete exposure. (Author)

  10. Boron thermal/epithermal neutron capture therapy

    International Nuclear Information System (INIS)

    Fairchild, R.G.

    1982-01-01

    The development of various particle beams for radiotherapy represents an attempt to improve dose distribution, and to provide high LET radiations which are less sensitive to ambient physical and radiobiological factors such as oxygen tension, cell cycle, and dose rate. In general, a compromise is necessary as effective RBE is reduced in order to spread the dose distribution over the anticipated tumor volume. The approach of delivering stable non-toxic isotopes to tumor, and then activating these atoms subsequently via an external radiation beam has mator advantages; problems associated with high uptake of these isotopes in competing cell pools are obviated, and the general tumor volume can be included in the treatment field of the activating beam. As long as the normal tissues supporting tumor show a low uptake of the isotope to be activated, and as long as the range of the reaction products is short, dose will be restricted to tumor, with a consequent high therapeutic ratio. Neutron Capture Therapy (NCT) is generally carried out by activating boron-10 with low energy neutrons. The range of the high LET, low OER particles from the 10 B(n, α) 7 Li reaction is approx. 10μ, or one cell diameter, a situation that is optimal for cell killing. Significant advantages may be gained by using the NCT procedure in conjunction with improved tissue penetration provided with epithermal or filtered beams, and new compounds showing physiological binding to tumor

  11. Dose planning with comparison to in vivo dosimetry for epithermal neutron irradiation of the dog brain

    International Nuclear Information System (INIS)

    Seppaelae, Tiina; Auterinen, Iiro; Aschan, Carita; Seren, Tom; Benczik, Judit; Snellman, Marjatta; Huiskamp, Rene; Ramadan, Usama Abo; Kankaanranta, Leena; Joensuu, Heikki; Savolainen, Sauli

    2002-01-01

    Boron neutron capture therapy (BNCT) is an experimental type of radiotherapy, presently being used to treat glioblastoma and melanoma. To improve patient safety and to determine the radiobiological characteristics of the epithermal neutron beam of Finnish BNCT facility (FiR 1) dose-response studies were carried on the brain of dogs before starting the clinical trials. A dose planning procedure was developed and uncertainties of the epithermal neutron-induced doses were estimated. The accuracy of the method of computing physical doses was assessed by comparing with in vivo dosimetry. Individual radiation dose plans were computed using magnetic resonance images of the heads of 15 Beagle dogs and the computational model of the FiR 1 epithermal neutron beam. For in vivo dosimetry, the thermal neutron fluences were measured using Mn activation foils and the gamma-ray doses with MCP-7s type thermoluminescent detectors placed both on the skin surface of the head and in the oral cavity. The degree of uncertainty of the reference doses at the thermal neutron maximum was estimated using a dose-planning program. The estimated uncertainty (±1 standard deviation) in the total physical reference dose was ±8.9%. The calculated and the measured dose values agreed within the uncertainties at the point of beam entry. The conclusion is that the dose delivery to the tissue can be verified in a practical and reliable fashion by placing an activation dosimeter and a TL detector at the beam entry point on the skin surface with homogeneous tissues below. However, the point doses cannot be calculated correctly in the inhomogeneous area near air cavities of the head model with this type of dose-planning program. This calls for attention in dose planning in human clinical trials in the corresponding areas

  12. Installation and testing of an optimized epithermal neutron beam at the Brookhaven Medical Research Reactor (BMRR)

    Energy Technology Data Exchange (ETDEWEB)

    Fairchild, R.G.; Kalef-Ezra, J.; Saraf, S.K.; Fiarman, S.; Ramsey, E.; Wielopolski, L.; Laster, B.; Wheeler, F. (Brookhaven National Lab., Upton, NY (USA); Ioannina Univ. (Greece); Brookhaven National Lab., Upton, NY (USA); State Univ. of New York, Stony Brook, NY (USA). Health Science Center; Brookhaven National Lab., Upton, NY (USA); EG and G Idaho, Inc., Idaho Falls, ID (USA))

    1989-01-01

    Various calculations indicate that an optimized epithermal neutron beam can be produced by moderating fission neutrons either with a combination of Al and D{sub 2}O, or with Al{sub 2}O{sub 3}. We have designed, installed and tested an Al{sub 2}O{sub 3} moderated epithermal neutron beam at the Brookhaven Medical Research Reactor (BMRR). The epithermal neutron fluence rate of 1.8 {times} 10{sup 9} n/cm{sup 2}-sec produces a peak thermal neutron fluence rate of 1.9 to 2.8 {times} 10{sup 9} n/cm{sup 2}-sec in a tissue equivalent (TE) phantom head, depending on the configuration. Thus a single therapy treatment of 5 {times} 10{sup 12} n/cm{sup 2} can be delivered in 30--45 minutes. All irradiation times are given for a BMRR power of 3 MW, which is the highest power which can be delivered continuously. 18 refs., 8 figs., 4 tabs.

  13. 8-group relative delayed neutron yields for epithermal neutron induced fission of 235U and 239Pu

    International Nuclear Information System (INIS)

    Piksaikin, V.M.; Kazakov, L.E.; Isaev, S.G.; Korolev, G.G.; Roshchenko, V.A.; Tertychnyj, R.G

    2002-01-01

    An 8-group representation of relative delayed neutron yields was obtained for epithermal neutron induced fission of 235 U and 239 Pu. These data were compared with ENDF/B-VI data in terms of the average half- life of the delayed neutron precursors and on the basis of the dependence of reactivity on the asymptotic period. (author)

  14. Characterization of the γ background in epithermal neutron scattering measurements at pulsed neutron sources

    International Nuclear Information System (INIS)

    Pietropaolo, A.; Tardocchi, M.; Schooneveld, E.M.; Senesi, R.

    2006-01-01

    This paper reports the characterization of the different components of the γ background in epithermal neutron scattering experiments at pulsed neutron sources. The measurements were performed on the VESUVIO spectrometer at ISIS spallation neutron source. These measurements, carried out with a high purity germanium detector, aim to provide detailed information for the investigation of the effect of the γ energy discrimination on the signal-to-background ratio. It is shown that the γ background is produced by different sources that can be identified with their relative time structure and relative weight

  15. Determination of uranium in tree bark samples by epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Lima, Nicole Pereira de; Saiki, Mitiko

    2017-01-01

    In this study uranium (U) concentrations were determined in certified reference materials (CRMs) and in tree bark samples collected in 'Cidade Universitaria Armando de Salles Oliveira' (CUASO) USP, Sao Paulo, SP, Brazil). The barks were collected from different species namely Poincianella pluviosa and Tipuana tipu. These bark samples were cleaned, dried, grated and milled for the analyses by epithermal neutron activation analysis method (ENAA). This method consists on irradiating samples and U standard in IEAR1 nuclear reactor with thermal neutron flux of 1:9 x 10 12 n cm -2 s -1 during 40 to 60 seconds depending on the samples matrices. The samples and standard were measured by gamma ray spectroscopy. U was identified by the peak of 74.66 keV of 239 U with half life of 23.47 minutes. Concentration of U was calculated by comparative method. For analytical quality control of U results, certified reference materials were analysed. Results obtained for CRMs presented good precision and accuracy, with |Z score| <= 0.39. Uranium concentrations in tree barks varied from 83.1 to 627.6 ng g - 1 and the relative standard deviations of these results ranged from 1.8 to 10%. (author)

  16. Determination of uranium in tree bark samples by epithermal neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Nicole Pereira de; Saiki, Mitiko, E-mail: mitiko@ipen.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    In this study uranium (U) concentrations were determined in certified reference materials (CRMs) and in tree bark samples collected in 'Cidade Universitaria Armando de Salles Oliveira' (CUASO) USP, Sao Paulo, SP, Brazil). The barks were collected from different species namely Poincianella pluviosa and Tipuana tipu. These bark samples were cleaned, dried, grated and milled for the analyses by epithermal neutron activation analysis method (ENAA). This method consists on irradiating samples and U standard in IEAR1 nuclear reactor with thermal neutron flux of 1:9 x 10{sup 12} n cm{sup -2} s{sup -1} during 40 to 60 seconds depending on the samples matrices. The samples and standard were measured by gamma ray spectroscopy. U was identified by the peak of 74.66 keV of {sup 239}U with half life of 23.47 minutes. Concentration of U was calculated by comparative method. For analytical quality control of U results, certified reference materials were analysed. Results obtained for CRMs presented good precision and accuracy, with |Z score| <= 0.39. Uranium concentrations in tree barks varied from 83.1 to 627.6 ng g{sup -} {sup 1} and the relative standard deviations of these results ranged from 1.8 to 10%. (author)

  17. Marine Gradients of Halogens in Moss Studied by Epithermal Neutron Activation Analysis

    CERN Document Server

    Frontasyeva, M V

    2002-01-01

    Epithermal neutron activation analysis is known to be a powerful technique for the simultaneous study of chlorine, bromine and iodine in environmental samples. In this paper it is shown to be useful to elucidate marine gradients of these elements. Examples are from a transect study in northern Norway where samples of the feather moss Hylocomium splendens were collected at distances 0-300 km from the coastline. All three elements decreased exponentially as a function of distance from the ocean in the moss samples, strongly indicating that atmospheric supply from the marine environment is the predominant source of these elements to the terrestrial ecosystem. These results are compared with similar data for surface soils along the same gradients. Comparison is also made with previous data for halogens in moss in Norway obtained by conventional NAA and covering similar transects in other geographical regions. The Cl/Br and Br/I ratios in moss showed a regular change distance from the ocean in all transects, and h...

  18. Epithermal Neutron Activation Analysis (ENAA) of Cr(VI)-reducer Basalt-inhabiting Bacteria

    CERN Document Server

    Tsibakhashvili, N Ya; Kirkesali, E I; Aksenova, N G; Kalabegishvili, T L; Murusidze, I G; Mosulishvili, L M; Holman, H Y N

    2005-01-01

    Epithermal neutron activation analysis (ENAA) has been applied to studying elemental composition of Cr(VI)-reducer bacteria isolated from polluted basalts from the Republic of Georgia. Cr(VI)-reducing ability of the bacteria was examined by electron spin resonance (ESR) demonstrating that the bacteria differ in the rates of Cr(VI) reduction. A well-pronounced correlation between the ability of the bacteria to accumulate Cr(V) and their ability to reduce Cr(V) to Cr(III) observed in our experiments is discussed. Elemental analysis of these bacteria also revealed that basalt-inhabiting bacteria are distinguished by relative contents of essential elements such as K, Na, Mg, Fe, Mn, Zn, and Co. A high rate of Cr(III) formation correlates with a high concentration of Co in the bacterium. ENAA detected some similarity in the elemental composition of the bacteria. The relatively high contents of Fe detected in the bacteria (140-340 $\\mu $g/g of dry weight) indicate bacterial adaptation to the environmental condition...

  19. Application of epithermal neutron activation analysis to investigate accumulation and adsorption of mercury by Spirulina platensis biomass

    International Nuclear Information System (INIS)

    Mosulishvili, L.M.; Belokobyl'skij, A.I.; Khizanishvili, A.I.; Frontas'eva, M.V.; Kirkesali, E.I.; Aksenova, N.G.

    2004-01-01

    Epithermal neutron activation analysis was used to study interaction of blue-green alga Spirulina platensis with toxic metal mercury. Various concentrations of Hg(II) were added to cell cultures in a nutrient medium. The dynamics of accumulation of Hg was investigated over several days in relation to Spirulina biomass growth. The process of Hg adsorption by Spirulina biomass was studied in short-time experiments. The isotherm of adsorption was carried out in Freindlich coordinates. Natural Spirulina biomass has potential to be used in the remediation of sewage waters at Hg concentrations ∼100 μg/1

  20. Application of Epithermal Neutron Activation Analysis to Investigate Accumulation and Adsorption of Mercury by Spirulina platensis Biomass

    CERN Document Server

    Mosulishvili, L M; Khizanishvili, A I; Frontasyeva, M V; Kirkesali, E I; Aksenova, N G

    2004-01-01

    Epithermal neutron activation analysis was used to study interaction of blue-green alga Spirulina platensis with toxic metal mercury. Various concentrations of Hg(II) were added to cell cultures in a nutrient medium. The dynamics of accumulation of Hg was investigated over several days in relation to Spirulina biomass growth. The process of Hg adsorption by Spirulina biomass was studied in short-time experiments. The isotherm of adsorption was carried out in Freindlich coordinates. Natural Spirulina biomass has potential to be used in the remediation of sewage waters at Hg concentrations \\sim 100 {\\mu}g/l.

  1. Power Burst Reactor Facility as an epithermal neutron source for brain cancer therapy

    International Nuclear Information System (INIS)

    Wheeler, F.J.

    1986-01-01

    The Power Burst Facility (PBF) reactor is considered for modification to provide an intense, clean source of intermediate-energy (epithermal) neutrons desirable for clinical studies of neutron capture therapy (NCT) for malignant tumors. The modifications include partial replacement of the reflector, installation of a neutron-moderating, shifting region, additional shielding, and penetration of the present concrete shield with a collimating (and optionally) filtering region. The studies have indicated that the reactor, after these modifications, will be safely operable at full power (28 MW) within the acceptable limits of the plant protection systems. The neutron beam exiting from the collimator port is predicted to be of sufficient intensity (approx.10 10 neutrons/cm 2 -s) to provide therapeutic doses in very short irradiation times. The beam would be relatively free of undesirable fast neutrons, thermal neutrons and gamma rays. The calculated neutron energy spectrum and associated gamma rays in the beam were provided as input in simulation studies that used a computer model of a patient with a brain tumor to determine predicted dose rates to the tumor and healthy tissue. The results of this conceptual study indicate an intense, clean beam of epithermal neutrons for NCT clinical trials is attainable in the PBF facility with properly engineered design modifications. 9 refs., 11 figs., 3 tabs

  2. Boron neutron capture therapy (BNCT). Recent aspect, a change from thermal neutron to epithermal neutron beam and a new protocol

    International Nuclear Information System (INIS)

    Nakagawa, Yoshinobu

    1999-01-01

    Since 1968, One-hundred seventy three patients with glioblastoma (n=81), anaplastic astrocytoma (n=44), low grade astrocytoma (n=16) or other types of tumor (n=32) were treated by boron-neutron capture therapy (BNCT) using a combination of thermal neutron and BSH in 5 reactors (HTR n=13, JRR-3 n=1, MuITR n=98, KUR n=28, JRR-2 n=33). Out of 101 patients with glioma treated by BNCT under the recent protocol, 33 (10 glioblastoma, 14 anaplastic astrocytoma, 9 low grade astrocytoma) patients lived or have lived longer than 3 years. Nine of these 33 lived or have lived longer than 10 years. According to the retrospective analysis, the important factors related to the clinical results were tumor dose radiation dose and maximum radiation dose in thermal brain cortex. The result was not satisfied as it was expected. Then, we decided to introduce mixed beams which contain thermal neutron and epithermal neutron beams. KUR was reconstructed in 1996 and developed to be available to use mixed beams. Following the shutdown of the JRR-2, JRR-4 was renewed for medical use in 1998. Both reactors have capacity to yield thermal neutron beam, epithermal neutron beam and mixed beams. The development of the neutron source lead us to make a new protocol. (author)

  3. Filtered epithermal quasi-monoenergetic neutron beams at research reactor facilities

    International Nuclear Information System (INIS)

    Mansy, M.S.; Bashter, I.I.; El-Mesiry, M.S.; Habib, N.; Adib, M.

    2015-01-01

    Filtered neutron techniques were applied to produce quasi-monoenergetic neutron beams in the energy range of 1.5–133 keV at research reactors. A simulation study was performed to characterize the filter components and transmitted beam lines. The filtered beams were characterized in terms of the optimal thickness of the main and additive components. The filtered neutron beams had high purity and intensity, with low contamination from the accompanying thermal emission, fast neutrons and γ-rays. A computer code named “QMNB” was developed in the “MATLAB” programming language to perform the required calculations. - Highlights: • Quasi-monoenergetic neutron beams in energy range from (1.5–133) keV. • Interference between the resonance and potential scattering amplitudes. • Epithermal neutron beams used in BNCT

  4. Upgrade for the epithermal neutron beam at NRI Rez

    International Nuclear Information System (INIS)

    Marek, M.; Flibor, S.; Viererbl, L.; Burian, J.; Rejchrt, J.; Klupak, V.; Gambarini, G.; Vanossi, E.

    2006-01-01

    The epithermal neutron beam facility designed for pre-clinical neutron capture therapy research has been operated at LVR-15 reactor for more than ten years. The construction of the beam filter has been recently modified especially for the shielding quality of the beam shutter to be improved. The parameters of the upgraded beam were calculated with the MCNP code and a new source term for the NCTPLAN treatment planning software was evaluated. The calculated source term was consequently scaled according to the results of measurements in the free beam and in the 50x50x25 cm 3 water phantom. (author)

  5. Qualitative dose response of the normal canine head to epithermal neutron irradiation with and without boron capture

    International Nuclear Information System (INIS)

    DeHaan, C.E.; Gavin, P.R.; Kraft, S.L.; Wheeler, F.J.; Atkinson, C.A.

    1992-01-01

    Boron Neutron Capture Therapy is being re-evaluated for the treatment of intracranial tumors. Prior to human clinical trials, determination of normal tissue tolerance is critical. Dogs were chosen as a large animal model for the following reasons. Dogs can be evaluated with advanced imaging, diagnostic and therapeutic modalities. Dogs are amenable to detailed neurologic examination and subtle behavioral changes are easily detected. Specifically, Labrador retrievers were chosen for their large body and head size. The dogs received varying doses of epithermal neutron irradiation and boron neutron capture irradiation using an epithermal neutron source. The dogs were closely monitored for up to one year post irradiation

  6. Elimination of eight interfering radioisotopes in the determination of uranium by activation analysis with epithermic neutrons

    International Nuclear Information System (INIS)

    Requejo, C.S.

    1977-01-01

    The total or parcial elimination interfering radioisotopes in activation analysis of uranium by epithermic neutrons, has been made. It was possible to determine uranium, after chemical separation, from samples of organic and mineral matrixes, which had mercury, selenium, bromine, antimony, gold, barium, molybden and tungsten. Mineral samples were analysed giving results between 0.2 to 5.0 ppm of uranium. The same mineral were ground in agate mortar and in tungsten carbide mill. In the first sample is has been found 0.2277 +- -+ 0.0474 ppm U. The second which had tungsten, at level of 150 ppm, after radiochemical separation, it has been found 0.2465+- -+0.0326 ppm U. These results are considered statistically the same [pt

  7. Epithermal neutron beam design for neutron capture therapy at the Power Burst Facility and the Brookhaven Medical Research Reactor

    International Nuclear Information System (INIS)

    Wheeler, F.J.; Parsons, D.K.; Rushton, B.L.; Nigg, D.W.

    1990-01-01

    Nuclear design studies have been performed for two reactor-based epithermal neutron beams for cancer treatment by neutron capture therapy (NCT). An intermediate-intensity epithermal beam has been designed and implemented at the Brookhaven Medical Research Reactor (BMRR). Measurements show that the BMRR design predictions for the principal characteristics of this beam are accurate. A canine program for research into the biological effects of NCT is now under way at BMRR. The design for a high-intensity epithermal beam with minimal contamination from undesirable radiation components has been finalized for the Power Burst Facility (PBF) at the Idaho National Engineering Laboratory. This design will be implemented when it is determined that human NCT trials are advisable. The PBF beam will exhibit approximately an order of magnitude improvement in absolute epithermal flux intensity over that available in the BMRR, and its angular distribution and spectral characteristics will be more advantageous for NCT. The combined effects of beam intensity, angular distribution, spectrum, and contaminant level allow the desired tumor radiation dose to be delivered in much shorter times than are possible with the currently available BMRR beam, with a significant reduction (factor of 3 to 5) in collateral dose due to beam contaminants

  8. Collimator optimization studies for the new MIT epithermal neutron beam

    International Nuclear Information System (INIS)

    Riley, K.J.; Ali, S.J.; Harling, O.K.

    2000-01-01

    A patient collimator has been designed for the epithermal neutron facility now being commissioned at MIT. Collimator performance both in and out of field was evaluated using the Monte Carlo code MCNP. A two piece design that can accommodate different circular field sizes will be manufactured using a composite lead, epoxy, boron and lithium mixture. (author)

  9. Study on the dose distribution of the mixed field with thermal and epi-thermal neutrons for neutron capture therapy

    International Nuclear Information System (INIS)

    Kobayashi, Tooru; Sakurai, Yoshinori; Kanda, Keiji

    1994-01-01

    Simulation calculations using DOT 3.5 were carried out in order to confirm the characteristics of depth-dependent dose distribution in water phantom dependent on incident neutron energy. The epithermal neutrons mixed to thermal neutron field is effective improving the thermal neutron depth-dose distribution for neutron capture therapy. A feasibility study on the neutron energy spectrum shifter was performed using ANISN-JR for the KUR Heavy Water Facility. The design of the neutron spectrum shifter is feasible, without reducing the performance as a thermal neutron irradiation field. (author)

  10. YAP scintillators for resonant detection of epithermal neutrons at pulsed neutron sources

    International Nuclear Information System (INIS)

    Tardocchi, M.; Gorini, G.; Pietropaolo, A.; Andreani, C.; Senesi, R.; Rhodes, N.; Schooneveld, E. M.

    2004-01-01

    Recent studies indicate the resonance detector (RD) technique as an interesting approach for neutron spectroscopy in the electron volt energy region. This work summarizes the results of a series of experiments where RD consisting of YAlO 3 (YAP) scintillators were used to detect scattered neutrons with energy in the range 1-200 eV. The response of YAP scintillators to radiative capture γ emission from a 238 U analyzer foil was characterized in a series of experiments performed on the VESUVIO spectrometer at the ISIS pulsed neutron source. In these experiments a biparametric data acquisition allowed the simultaneous measurements of both neutron time-of-flight and γ pulse height (energy) spectra. The analysis of the γ pulse height and neutron time of flight spectra permitted to identify and distinguish the signal and background components. These measurements showed that a significant improvement in the signal-to-background ratio can be achieved by setting a lower level discrimination on the pulse height at about 600 keV equivalent photon energy. Present results strongly indicate YAP scintillators as the ideal candidate for neutron scattering studies with epithermal neutrons at both very low (<5 deg.) and intermediate scattering angles

  11. Epithermal beam development at the BMRR [Brookhaven Medical Research Reactor]: Dosimetric evaluation

    International Nuclear Information System (INIS)

    Saraf, S.K.; Fairchild, R.G.; Kalef-Ezra, J.; Laster, B.H.; Fiarman, S.; Ramsey, E.; Ioannina Univ.; Brookhaven National Lab., Upton, NY; State Univ. of New York, Stony Brook, NY

    1989-01-01

    The utilization of an epithermal neutron beam for neutron capture therapy (NCT) is desirable because of the increased tissue penetration relative to a thermal neutron beam. Over the past few years, modifications have been and continue to be made at the Brookhaven Medical Research Reactor (BMRR) by changing its filter components to produce an optimal epithermal beam. An optimal epithermal beam should contain a low fast neutron contamination and no thermal neutrons in the incident beam. Recently a new moderator for the epithermal beam has been installed at the epithermal port of the BMRR and has accomplished this task. This new moderator is a combination of alumina (Al 2 O 3 ) bricks and aluminum (Al) plates. A 0.51 mm thick cadmium (Cd) sheet has reduced the thermal neutron intensity drastically. Furthermore, an 11.5 cm thick bismuth (Bi) plate installed at the port surface has reduced the gamma dose component to negligible levels. Foil activation techniques have been employed by using bare gold and cadmium-covered gold foil to determine thermal as well as epithermal neutron fluence. Fast neutron fluence has been determined by indium foil counting. Fast neutron and gamma dose in soft tissue, free in air, is being determined by the paired ionization chamber technique, using tissue equivalent (TE) and graphite chambers. Thermoluminescent dosimeters (TLD-700) have also been used to determine the gamma dose independently. This paper describes the methods involved in the measurements of the above mentioned parameters. Formulations have been developed and the various corrections involved have been detailed. 12 refs

  12. Fundamental symmetry studies at Los Alamos using epithermal neutrons

    International Nuclear Information System (INIS)

    Bowman, C.D.; Bowman, J.D.; Yuan, V.W.

    1988-01-01

    Fundamental symmetry studies using intense polarized beams of epithermal neutrons are underway at the LANSCE facility of the Los Alamos National Laboratory. Three classes of symmetry experiments can be explored: parity violation, and time reversal invariance violation for both parity-violating and parity-conserved observables. The experimental apparatus is described and performance illustrated with examples of recent measurements. Possible improvements in the facilities and prospective experiments are discussed. 15 refs., 10 figs

  13. Elemental analysis of brazing alloy samples by neutron activation technique

    International Nuclear Information System (INIS)

    Eissa, E.A.; Rofail, N.B.; Hassan, A.M.; El-Shershaby, A.; Walley El-Dine, N.

    1996-01-01

    Two brazing alloy samples (C P 2 and C P 3 ) have been investigated by Neutron activation analysis (NAA) technique in order to identify and estimate their constituent elements. The pneumatic irradiation rabbit system (PIRS), installed at the first egyptian research reactor (ETRR-1) was used for short-time irradiation (30 s) with a thermal neutron flux of 1.6 x 10 1 1 n/cm 2 /s in the reactor reflector, where the thermal to epithermal neutron flux ratio is 106. Long-time irradiation (48 hours) was performed at reactor core periphery with thermal neutron flux of 3.34 x 10 1 2 n/cm 2 /s, and thermal to epithermal neutron flux ratio of 79. Activation by epithermal neutrons was taken into account for the (1/v) and resonance neutron absorption in both methods. A hyper pure germanium detection system was used for gamma-ray acquisitions. The concentration values of Al, Cr, Fe, Co, Cu, Zn, Se, Ag and Sb were estimated as percentages of the sample weight and compared with reported values. 1 tab

  14. Elemental analysis of brazing alloy samples by neutron activation technique

    Energy Technology Data Exchange (ETDEWEB)

    Eissa, E A; Rofail, N B; Hassan, A M [Reactor and Neutron physics Department, Nuclear Research Centre, Atomic Energy Authority, Cairo (Egypt); El-Shershaby, A; Walley El-Dine, N [Physics Department, Faculty of Girls, Ain Shams Universty, Cairo (Egypt)

    1997-12-31

    Two brazing alloy samples (C P{sup 2} and C P{sup 3}) have been investigated by Neutron activation analysis (NAA) technique in order to identify and estimate their constituent elements. The pneumatic irradiation rabbit system (PIRS), installed at the first egyptian research reactor (ETRR-1) was used for short-time irradiation (30 s) with a thermal neutron flux of 1.6 x 10{sup 1}1 n/cm{sup 2}/s in the reactor reflector, where the thermal to epithermal neutron flux ratio is 106. Long-time irradiation (48 hours) was performed at reactor core periphery with thermal neutron flux of 3.34 x 10{sup 1}2 n/cm{sup 2}/s, and thermal to epithermal neutron flux ratio of 79. Activation by epithermal neutrons was taken into account for the (1/v) and resonance neutron absorption in both methods. A hyper pure germanium detection system was used for gamma-ray acquisitions. The concentration values of Al, Cr, Fe, Co, Cu, Zn, Se, Ag and Sb were estimated as percentages of the sample weight and compared with reported values. 1 tab.

  15. Epithermal neutron activation analysis of CR(VI)-reducer basalt-inhabiting bacteria

    International Nuclear Information System (INIS)

    Tsibakhashvili, N.Ya.; Kalabegishvili, T.L.; Murusidze, I.G.; Mosulishvili, L.M.; Frontas'eva, M.V.; Kirkesali, E.I.; Aksenova, N.G.; Holman, H.Y.

    2005-01-01

    Epithermal neutron activation analysis (ENAA) has been applied to studying elemental composition of Cr(VI)-reducer bacteria isolated from polluted basalts from the Republic of Georgia. Cr(VI)-reducing ability of the bacteria was examined by electron spin resonance (ESR) demonstrating that the bacteria differ in the rates of Cr(VI) reduction. A well-pronounced correlation between the ability of the bacteria to accumulate Cr(VI) and their ability to reduce Cr(V) to Cr(III) observed in our experiments is discussed. Elemental analysis of these bacteria also revealed that basalt-inhabiting bacteria are distinguished by relative contents of essential elements such as K, Na, Mg, Fe, Mn, Zn, and Co. A high rate of Cr(III) formation correlates with a high concentration of Co in the bacterium. ENAA detected some similarity in the elemental composition of the bacteria. The relatively high contents of Fe detected in the bacteria (140-340 μg/g of dry weight) indicate bacterial adaptation to the environmental conditions typical of the basalts. The concentrations of at least 12-19 different elements ranging from major- to ultratrace ones were determined in each type of bacteria simultaneously. The range of concentrations spans over 8 orders of magnitude

  16. Epithermal neutron activation analysis of Spirulina platensis biomass, of the C-phycocianin and of DNA extracted from it

    International Nuclear Information System (INIS)

    Mosulishvili, L.M.; Belokobyl'skij, A.I.; Kirkesali, E.I.; Khizanishvili, A.I.; Frontas'eva, M.V.; Pomyakushina, E.V.

    2002-01-01

    The epithermal neutron activation analysis (ENAA) was used for study of the biomass of Spirulina platensis. The background levels of concentration of 27 macro-, micro- and trace elements ranging from 10 -3 up to 10 4 ppm were determined. It was found that the biomass of Spirulina does not contain toxic elements above the tolerance levels and can be utilized as a matrix of pharmaceuticals based on it. The concentrations of basic elements in C-phycocianin and DNA extracted from Spirulina platensis were determined by ENAA. A comparison of the element content of a whole Spirulina biomass with that of a refined C-phycocianin preparation was made

  17. Epithermal Neutron Activation Analysis of Spirulina platensis Biomass, of the C-Phycocianin and of DNA Extracted from It

    CERN Document Server

    Mosulishvili, L M; Belokobylsky, A I; Kirkesali, E I; Khizanishvili, A I; Pomyakushina, E V

    2002-01-01

    The epithermal neutron activation analysis (ENAA) was used for study of the biomass of Spirulina platensis. The background levels of concentration 27 macro-, micro- and trace elements ranging from 10^{-3} up to 10^{4} ppm were determined. It was found that the biomass of spirulina does not contain toxic elements above the tolerance levels and can be utilized as a matrix of pharmaceuticals based on it. The concentrations of basic elements in C-phycocianin and DNA extracted from Spirulina platensis were determined by ENAA. A comparison of the element content of a whole spirulina biomass with that of a refined C-phycocianin preparation was made.

  18. The determination of self-powered neutron detector sensitivity on thermal and epithermal neutron flux densities

    International Nuclear Information System (INIS)

    Erben, O.

    1980-01-01

    The coefficients of thermal and epithermal neutron flux density depression and self-shielding for the SPN detectors with vanadium, rhodium, silver and cobalt emitters are presented, (for cobalt SPN detectors the functions describing the absorbtion of neutrons along the emitter cross-section are also shown). Using these coefficients and previously published beta particle escape efficiencies, sensitivities are determined for the principal types of detectors produced by Les Cables de Lyon and SODERN companies. The experiments and their results verifying the validity of the theoretical work are described. (author)

  19. A preliminary inter-centre comparison study for photon, thermal neutron and epithermal neutron responses of two pairs of ionisation chambers used for BNCT

    International Nuclear Information System (INIS)

    Roca, Antoaneta; Liu, Yuan-Hao; Wojnecki, Cecile; Green, Stuart; Nievaart, Sander; Ghani, Zamir; Moss, Ray

    2009-01-01

    The dual ionisation chamber technique is the recommended method for mixed field dosimetry of epithermal neutron beams. This paper presents initial data from an ongoing inter-comparison study involving two identical pairs of ionisation chambers used at the BNCT facilities of Petten, NL and of University of Birmingham, UK. The goal of this study is to evaluate the photon, thermal neutron and epithermal neutron responses of both pairs of TE(TE) (Exradin T2 type) and Mg(Ar) (Exradin M2 type) ionisation chambers in similar experimental conditions. At this stage, the work has been completed for the M2 type chambers and is intended to be completed for the T2 type chambers in the near future.

  20. Characterisation of the TAPIRO BNCT epithermal facility

    Energy Technology Data Exchange (ETDEWEB)

    Burn, K. W. [FIS-NUC, ENEA, Via Martiri di Montesole 4, Bologna (Italy); Colli, V. [Dept. of Physics of Univ., INFN, Via Celoria 16, I-20133 Milano (Italy); Curzio, G.; D' Errico, F. [DIMNP, Univ. of Pisa, Via Diotisalvi 2, I-56126 Pisa (Italy); Gambarini, G. [Dept. of Physics of Univ., INFN, Via Celoria 16, I-20133 Milano (Italy); Rosi, G. [FIS-ION, ENEA, Casaccia, Via Anguillarese 301, I-00060 Santa Maria di Galeria, Roma (Italy); Scolari, L. [Dept. of Physics of Univ., INFN, Via Celoria 16, I-20133 Milano (Italy)

    2004-07-01

    A collimated epithermal beam for boron neutron capture therapy (BNCT) research has been designed and built at the TAPIRO fast research reactor. A complete experimental characterisation of the radiation field in the irradiation chamber has been performed, to verify agreement with IAEA requirements. Slow neutron fluxes have been measured by means of an activation technique and with thermoluminescent detectors (TLDs). The fast neutron dose has been determined with gel dosemeters, while the fast neutron spectrum has been acquired by means of a neutron spectrometer based on superheated drop detectors. The gamma-dose has been measured with gel dosemeters and TLDs. For an independent verification of the experimental results, fluxes, doses and neutron spectra have been calculated with Monte Carlo simulations using the codes MCNP4B and MCNPX 2.1.5 with the direct statistical approach (DSA). The results obtained confirm that the epithermal beams achievable at TAPIRO are of suitable quality for BNCT purposes. (authors)

  1. Study on iodine levels in thyroids of iodine-supplemented rats by epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Wang Xuefei; Zhang Fang; Xu Qing; Liu Nianqing; Chai Zhifang; Zhao Xueqin; Zuo Aijun

    2003-01-01

    The second generation female Wistar rats that have been treated with iodine-deficient food, after their delivery, are divided into three groups i.e. excessive-iodine (EI), adequate-iodine (AI) and iodine-deficient (ID) according to the KIO 3 concentration in the drinking water (3.0, 0.4, 0 mg/L). In addition, the normal rats with low iodine food and 0.4 mg/L KIO 3 water are used as the control group (C). The iodine content in thyroid and the serum thyroid hormone levels of the third generation rats are measured by means of epithermal neutron activation analysis (ENAA), and the method of enzyme-linked immunosorbent assay (ELISA), respectively. The results indicate that the total thyroxine (TT 4 ) and the free thyroxine (FT 4 ) of the EI, compared with those of the controls, are significantly decreased (p 3 ) evidently increased (p 4 , FT 4 and goiter

  2. Conceptual design of 30 MeV magnet system used for BNCT epithermal neutron source

    International Nuclear Information System (INIS)

    Slamet Santosa; Taufik

    2015-01-01

    Conceptual design of 30 MeV Magnet System Used for BNCT Epithermal Neutron Source has been done based on methods of empirical model of basic equation, experiences of 13 MeV cyclotron magnet design and personal communications. In the field of health, cyclotron can be used as an epithermal neutron source for Boron Neutron Capture Therapy (BNCT). The development of cyclotron producing epithermal neutrons for BNCT has been performed at Kyoto University, of which it produces a proton beam current of 1.1 mA with energy of 30 MeV. With some experiences on 13 MeV cyclotron magnet design, to support BNCT research and development we performed the design studies of 30 MeV cyclotron magnet system, which is one of the main components of the cyclotron for deflecting proton beam into circular trajectory and serves as beam focusing. Results of this study are expected to define the parameters of particular cyclotron magnet. The scope of this study includes the study of the parameters component of the 30 MeV cyclotron and magnet initial parameters. The empirical method of basic equation model is then corroborated by a simulation using Superfish software. Based on the results, a 30 MeV cyclotron magnet for BNCT neutron source enables to be realized with the parameters of B 0 = 1.06 T, frequency RF = 64.733938 ≈ 65 MHz, the external radius of 0.73 m, the radius of the polar = 0.85 m, BH = 1.95 T and a gap hill of 4 cm. Because proton beam current that be needed for BNCT application is very large, then in the calculation it is chosen a great focusing axial νz = 0.630361 which can generate B V = 0.44 T. (author)

  3. In vitro biological effectiveness of JRR-4 epithermal neutron beam. Experiment under free air beam and in water phantom. Cooperative research

    CERN Document Server

    Yamamoto, T; Horiguchi, Y; Kishi, T; Kumada, H; Matsumura, A; Nose, T; Torii, Y; Yamamoto, K

    2002-01-01

    The surviving curve and the biological effectiveness factor of dose components generated in boron neutron capture therapy (BNCT) were separately determined in neutron beams at Japan Research Reactor No.4. Surviving fraction of V79 Chinese hamster cell with or without sup 1 sup 0 B was obtained using an epithermal neutron beam (ENB), a mixed thermal-epithermal neutron beam (TNB-1), and a thermal neutron beam (TNB-2), which were used or planned to use for BNCT clinical trial. The cell killing effect of these neutron beams with or without the presence of sup 1 sup 0 B depended highly on the neutron beam used, according to the epithermal and fast neutron content in the beam. The biological effectiveness factor values of the boron capture reaction for ENB, TNB-1 and TNB-2 were 3.99+-0.24, 3.04+-0.19 and 1.43+-0.08, respectively. The biological effectiveness factor values of the high-LET dose components based on the hydrogen recoils and the nitrogen capture reaction were 2.50+-0.32, 2.34+-0.30 and 2.17+-0.28 for EN...

  4. A spin-transport system for a longitudinally polarized epithermal neutron beam

    International Nuclear Information System (INIS)

    Crawford, B.E.; Bowman, J.D.; Penttilae, S.I.; Roberson, N.R.

    2001-01-01

    The TRIPLE (Time Reversal and Parity at Low Energies) collaboration uses a polarized epithermal neutron beam and a capture γ-ray detector to study parity violation in neutron-nucleus reactions. In order to preserve the spin polarization of the neutrons as they travel the 60-m path to the target, the beam pipes are wrapped with wire to produce a solenoidal magnetic field of about 10 G along the beam direction. The flanges and bellows between sections of the beam pipe cause gaps in the windings which in turn produce radial fields that can depolarize the neutron spins. A computer code has been developed that numerically evaluates the effect of these gaps on the polarization. A measurement of the neutron depolarization for neutrons in the actual spin-transport system agrees with a calculation of the neutron depolarization for the TRIPLE system. Features that will aid in designing similar spin-transport systems are discussed

  5. VLAD for epithermal neutron scattering experiments at large energy transfers

    International Nuclear Information System (INIS)

    Tardocchi, M; Gorini, G; Perelli-Cippo, E; Andreani, C; Imberti, S; Pietropaolo, A; Senesi, R; Rhodes, N R; Schooneveld, E M

    2006-01-01

    The Very Low Angle Detector (VLAD) bank will extend the kinematical region covered by today's epithermal neutron scattering experiments to low momentum transfer ( -1 ) together with large energy transfer 0 -4 0 . In this paper the design of VLAD is presented together with Montecarlo simulations of the detector performances. The results of tests made with prototype VLAD detectors are also presented, confirming the usefulness of the Resonance Detector for measurements at very low scattering angles

  6. Epithermal neutron flux in the experimental channels of the RA reactor; Fluks epitermalnih neutrona u eksperimentalnim kanalima reaktora RA

    Energy Technology Data Exchange (ETDEWEB)

    Raisic, N; Dobrosavljevic, N [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1961-12-15

    Epithermal neutron flux was determined by measuring the cadmium ratio from activation analysis of gold and indium foils. Irradiation was done in experimental channels VK-5, VK-2, VK-7, VK-0, VK-HS next to the core, and next to the fuels elements. Activation of bare foils and foils covered by 0.8 and 1.0 mm thick cadmium foils was done simultaneously. Activity was measured by GM counter. Corrections were done for resonant neutrons self-absorption since the foils used were too thick concerning most important resonances of gold and indium. Final results were presented as spectrum factor r for their direct use in determining the effective neutron cross sections.

  7. Metrology and quality of radiation therapy dosimetry of electron, photon and epithermal neutron beams

    Energy Technology Data Exchange (ETDEWEB)

    Kosunen, A

    1999-08-01

    In radiation therapy using electron and photon beams the dosimetry chain consists of several sequential phases starting by the realisation of the dose quantity in the Primary Standard Dosimetry Laboratory and ending to the calculation of the dose to a patient. A similar procedure can be described for the dosimetry of epithermal neutron beams in boron neutron capture therapy (BNCT). To achieve the required accuracy of the dose delivered to a patient the quality of all steps in the dosimetry procedure has to be considered. This work is focused on two items in the dosimetry chains: the determination of the dose in the reference conditions and the evaluation of the accuracy of dose calculation methods. The issues investigated and discussed in detail are: a)the calibration methods of plane parallel ionisation chambers used in electron beam dosimetry, (b) the specification of the critical dosimetric parameter i.e. the ratio of stopping powers for water to air, (S I ?){sup water} {sub air}, in photon beams, (c) the feasibility of the twin ionization chamber technique for dosimetry in epithermal neutron beams applied to BNCT and (d) the determination accuracy of the calculated dose distributions in phantoms in electron, photon, and epithermal neutron beams. The results demonstrate that up to a 3% improvement in the consistency of dose determinations in electron beams is achieved by the calibration of plane parallel ionisation chambers in high energy electron beams instead of calibrations in {sup 60}Co gamma beams. In photon beam dosimetry (S I ?){sup water} {sub air} can be determined with an accuracy of 0.2% using the percentage dose at the 10 cm depth, %dd(10), as a beam specifier. The use of %odd(10) requires the elimination of the electron contamination in the photon beam. By a twin ionisation chamber technique the gamma dose can be determined with uncertainty of 6% (1 standard deviation) and the total neutron dose with an uncertainty of 15 to 20% (1 standard deviation

  8. Metrology and quality of radiation therapy dosimetry of electron, photon and epithermal neutron beams

    International Nuclear Information System (INIS)

    Kosunen, A.

    1999-08-01

    In radiation therapy using electron and photon beams the dosimetry chain consists of several sequential phases starting by the realisation of the dose quantity in the Primary Standard Dosimetry Laboratory and ending to the calculation of the dose to a patient. A similar procedure can be described for the dosimetry of epithermal neutron beams in boron neutron capture therapy (BNCT). To achieve the required accuracy of the dose delivered to a patient the quality of all steps in the dosimetry procedure has to be considered. This work is focused on two items in the dosimetry chains: the determination of the dose in the reference conditions and the evaluation of the accuracy of dose calculation methods. The issues investigated and discussed in detail are: a)the calibration methods of plane parallel ionisation chambers used in electron beam dosimetry, (b) the specification of the critical dosimetric parameter i.e. the ratio of stopping powers for water to air, (S I ?) water air , in photon beams, (c) the feasibility of the twin ionization chamber technique for dosimetry in epithermal neutron beams applied to BNCT and (d) the determination accuracy of the calculated dose distributions in phantoms in electron, photon, and epithermal neutron beams. The results demonstrate that up to a 3% improvement in the consistency of dose determinations in electron beams is achieved by the calibration of plane parallel ionisation chambers in high energy electron beams instead of calibrations in 60 Co gamma beams. In photon beam dosimetry (S I ?) water air can be determined with an accuracy of 0.2% using the percentage dose at the 10 cm depth, %dd(10), as a beam specifier. The use of %odd(10) requires the elimination of the electron contamination in the photon beam. By a twin ionisation chamber technique the gamma dose can be determined with uncertainty of 6% (1 standard deviation) and the total neutron dose with an uncertainty of 15 to 20% (1 standard deviation). To improve the accuracy

  9. Epithermal neutron beam for BNCT research at the Washington State University TRIGA research reactor

    International Nuclear Information System (INIS)

    Nigg, D.W.; Venhuizen, J.R.; Wheeler, F.J.; Wemple, C.A.; Tripard, G.E.; Gavin, P.R.

    2000-01-01

    A new epithermal-neutron beam facility for BNCT (Boron Neutron Capture Therapy) research and boronated agent screening in animal models is in the final stages of construction at Washington State University (WSU). A key distinguishing feature of the design is the incorporation of a new, high-efficiency, neutron moderating and filtering material, Fluental, developed by the Technical Research Centre of Finland. An additional key feature is the provision for adjustable filter-moderator thickness to systematically explore the radiobiological consequences of increasing the fast-neutron contamination above the nominal value associated with the baseline system. (author)

  10. Depth-dose evaluation for lung and pancreas cancer treatment by BNCT using an epithermal neutron beam

    International Nuclear Information System (INIS)

    Matsumoto, Tetsuo; Fukushima, Yuji

    2000-01-01

    The depth-dose distributions were evaluated for possible treatment of both lung and pancreas cancers using an epithermal neutron beam. The MCNP calculations showed that physical dose in tumors were 6 and 7 Gy/h, respectively, for lung and pancreas, attaining an epithermal neutron flux of 5x10 8 ncm -2 s -1 . The boron concentrations were assumed at 100 ppm and 30 ppm, respectively, for lung and pancreas tumors and normal tissues contains 1/10 tumor concentrations. The dose ratios of tumor to normal tissue were 2.5 and 2.4, respectively, for lung and pancreas. The dose evaluation suggests that BNCT could be applied for both lung and pancreas cancer treatment. (author)

  11. Development of the Very Low Angle Detector (VLAD) for detection of epithermal neutrons at low momentum transfers

    International Nuclear Information System (INIS)

    Tardocchi, M.; Andreani, C.; Cremonesi, O.; Gorini, G.; Perelli-Cippo, E.; Pietropaolo, A.; Rhodes, N.; Schooneveld, E.; Senesi, R.

    2006-01-01

    New perspectives for epithermal neutron spectroscopy are opened up by the recent development of new instrumentation for inverse geometry time of flight spectrometers at pulsed neutron sources. One example is the Very Low Angle Detector (VLAD) bank which will be installed as an upgrade of the VESUVIO neutron spectrometer, at the ISIS pulsed neutron source. VLAD is developed for detecting epithermal neutrons in the 1-100 eV energy range at very low scattering angles (l deg. - 5 deg.). VLAD will extend the kinematical region covered by today's neutron scattering experiments to the region of low wave vector transfers ( -1 ) and high energy transfers (>1 eV). Accessing such kinematical region will allow new experimental studies in condensed matter systems. The neutron detection is based on Resonance Detectors (RD), which consist of the combination of a resonance foil used as neutron-to-gamma converter and a photon detector. The results obtained with a prototype VLAD detector confirm the potential of this kind of experiments at scattering angles as low as 2 deg. - 5 deg. GEANT4 simulations are used to address issues, such as detector cross talk, which arise with the construction of compact RD arrays

  12. Characterisation of the epithermal neutron irradiation facility at the Portuguese research reactor using MCNP.

    Science.gov (United States)

    Beasley, D G; Fernandes, A C; Santos, J P; Ramos, A R; Marques, J G; King, A

    2015-05-01

    The radiation field at the epithermal beamline and irradiation chamber installed at the Portuguese Research Reactor (RPI) at the Campus Tecnológico e Nuclear of Instituto Superior Técnico was characterised in the context of Prompt Gamma Neutron Activation Analysis (PGNAA) applications. Radiographic films, activation foils and thermoluminescence dosimeters were used to measure the neutron fluence and photon dose rates in the irradiation chamber. A fixed-source MCNPX model of the beamline and chamber was developed and compared to measurements in the first step towards planning a new irradiation chamber. The high photon background from the reactor results in the saturation of the detector and the current facility configuration yields an intrinsic insensitivity to various elements of interest for PGNAA. These will be addressed in future developments. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Physical parameters and biological effects of the LVR-15 epithermal neutron beam

    International Nuclear Information System (INIS)

    Burian, J.; Marek, M.; Rejchrt, J.; Viererbl, L.; Gambarini, G.; Mares, V.; Vanossi, E.; Judas, L.

    2006-01-01

    Monitoring of the physical and biological properties of the epithermal neutron beam constructed at the multipurpose LVR-15 nuclear reactor for NCT therapy of brain tumors showed that its physical and biological properties are stable in time and independent on an ad hoc reconfiguration of the reactor core before its therapeutic use. Physical parameters were monitored by measurement of the neutron spectrum, neutron profile, fast neutron kerma rate in tissue and photon absorbed dose, the gel dosimetry was used with the group of standard measurement methods. The RBE of the beam, as evaluated by 3 different biological models, including mouse intestine crypt regeneration assay, germinative zones of the immature rat brain and C6 glioma cells in culture, ranged from 1.70 to 1.99. (author)

  14. Internal-standard method for the determination of uranium, thorium, lanthanum and europium in carbonaceous shale and monazite by epithermal neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Shuenn-Gang; Tsai, Hui-Tuh; Wu, Shaw-Chii [Institute of Nuclear Energy Research, Lung-Tan (Taiwan, Republic of China)

    1981-10-03

    An internal-standard method was applied for the determination of uranium, thorium, lanthanum and europium is carbonaceous shale samples and monazite sand by epithermal neutron activation analysis using gold as an internal standard element. The samples were irradiated in a zero-power reactor at the Institute of Nuclear Energy Research and measured with a high-resolution Ge(Li) detector. The detection limit is 0.1 ppm for uranium and europium, 1 ppm for thorium, 5 ppm for lanthanum, and the realative error of all elements is within +-2.6%.

  15. A preliminary investigation on the epithermal flux depression effect due to cadmium box in a multiplying medium

    International Nuclear Information System (INIS)

    Ahmad, A.

    1983-01-01

    Cadmium boxes are widely used as filter in Reactor Neutron Activation Analysis (RNAA) for the irradiation of samples in epithermal neutrons. By virtue of being an absorber the cadmium boxes produce epithermal flux depression in the medium surrounding them. A preliminary study of this effect was carried out (author)

  16. The orientation effect in the activities of neutronic probes

    International Nuclear Information System (INIS)

    Vigon, M. A.

    1956-01-01

    The formulae relating activity and position of a neutron irradiated Indium foil, have been verified experimentally. Measurements with both thin and thick foils for epithermal neutrons and with thick foils for thermal neutrons have been carried out. The experimental results agree qualitatively with the theoretical predictions. (Author)

  17. Reactor beam calculations to determine optimum delivery of epithermal neutrons for treatment of brain tumors

    International Nuclear Information System (INIS)

    Wheeler, F.J.; Nigg, D.W.; Capala, J.

    1997-01-01

    Studies were performed to assess theoretical tumor control probability (TCP) for brain-tumor treatment with boron neutron capture therapy (BNCT) using epithermal neutron sources from reactors. The existing epithermal-neutron beams at the Brookhaven Medical Research Reactor Facility (BMRR), the Petten High Flux Reactor Facility (HWR) and the Finnish Research Reactor 1 (FIR1) have been analyzed and characterized using common analytical and measurement methods allowing for this inter-comparison. Each of these three facilities is unique and each offers an advantage in some aspect of BNCT, but none of these existing facilities excel in all neutron-beam attributes as related to BNCT. A comparison is therefore also shown for a near-optimum reactor beam which does not currently exist but which would be feasible with existing technology. This hypothetical beam is designated BNCT-1 and has a spectrum similar to the FIR-1, the mono-directionality of the HFR and the intensity of the BMRR. A beam very similar to the BNCT-1 could perhaps be achieved with modification of the BMRR, HFR, or FIR, and could certainly be realized in a new facility with today's technology

  18. Photon detectors for epithermal neutron scattering at high-ω and low-q

    International Nuclear Information System (INIS)

    Pietropaolo, A.; Senesi, R.; Tardocchi, M.; Andreani, C.; Gorini, G.

    2004-01-01

    Inelastic epithermal neutron scattering at high energy (ℎω≥1 eV) and low wave vector (q≤10 A -1 ) transfers is the unique technique for the investigation of high-energy excitations in a variety of systems, ranging from magnetic materials to semiconductors. The key issue in order to make these measurements feasible on inverse geometry spectrometers, is to develop suitable detection systems for neutrons in the energy range 1-100 eV. The Resonance Detector Spectrometer configuration has to be considered as the most promising approach for electron Volt neutron spectroscopy. This configuration will be employed in the new low angle detector bank, VLAD, planned for VESUVIO spectrometer operating at ISIS source

  19. Epithermal interrogation of fissile waste

    International Nuclear Information System (INIS)

    Coop, K.L.; Hollas, C.L.

    1996-01-01

    Self-shielding of interrogating thermal neutrons in lumps of fissile material can be a major source of error in transuranic waste assay using the widely employed differential dieaway technique. We are developing a new instrument, the combined thermal/epithermal neutron (CTEN) interrogation instrument to detect the occurrence of self- shielding and mitigate its effects. Neutrons are moderated in the graphite walls of the CTEN instrument to provide an interrogating flux of epithermal and thermal neutrons. The induced prompt fission neutrons are detected in proportional counters. We report the results of measurements made with the CTEN instrument, using minimal and highly self-shielding plutonium and uranium sources in 55 gallon drums containing a variety of mock waste matrices. Fissile isotopes and waste forms for which the method is most applicable, and limitations associated with the hydrogen content of the waste package/matrix are described

  20. OPTIMIZATION OF THE EPITHERMAL NEUTRON BEAM FOR BORON NEUTRON CAPTURE THERAPY AT THE BROOKHAVEN MEDICAL RESEARCH REACTOR.

    Energy Technology Data Exchange (ETDEWEB)

    HU,J.P.; RORER,D.C.; RECINIELLO,R.N.; HOLDEN,N.E.

    2002-08-18

    Clinical trials of Boron Neutron Capture Therapy for patients with malignant brain tumor had been carried out for half a decade, using an epithermal neutron beam at the Brookhaven's Medical Reactor. The decision to permanently close this reactor in 2000 cut short the efforts to implement a new conceptual design to optimize this beam in preparation for use with possible new protocols. Details of the conceptual design to produce a higher intensity, more forward-directed neutron beam with less contamination from gamma rays, fast and thermal neutrons are presented here for their potential applicability to other reactor facilities. Monte Carlo calculations were used to predict the flux and absorbed dose produced by the proposed design. The results were benchmarked by the dose rate and flux measurements taken at the facility then in use.

  1. Distribution of 35 Elements in Peat Cores from Ombrotrophic Bogs Studied by Epithermal Neutron Activation Analysis

    CERN Document Server

    Frontasyeva, M V

    2004-01-01

    In ombrotrophic bogs the surface peat layer is supplied with chemical substances only from the atmosphere. Peat cores from these bogs therefore can be used to study temporal trends in atmospheric deposition of pollutants. In this work epithermal neutron activation analysis was applied for the first time to study the distribution of 35 elements in peat profiles from ombrotrophic bogs. The selected examples were from Finnmark county in northern Norway: one pristine site far from any local pollution source, and another strongly affected by long-term operation of Russian copper-nickel smelters located close to the border. The elements are classified with respect to their behavior in the uppermost 40 cm of the peat, and similarities and differences between the two profiles are discussed. As compared with other more commonly used analytical techniques based on acid decomposition of the sample ENAA has the advantage of providing the total concentrations of the elements.

  2. Methodological developments and applications of neutron activation analysis

    International Nuclear Information System (INIS)

    Kucera, J.

    2007-01-01

    The paper reviews the author's experience acquired and achievements made in methodological developments of neutron activation analysis (NAA) of mostly biological materials. These involve epithermal neutron activation analysis, radiochemical neutron activation analysis using both single- and multi-element separation procedures, use of various counting modes, and the development and use of the self-verification principle. The role of NAA in the detection of analytical errors is discussed and examples of applications of the procedures developed are given. (author)

  3. Determination of elemental concentrations in airborne particulate matter in the City of Santiago de Chile, through neutron activation analysis using epithermal neutrons and Compton suppression system

    International Nuclear Information System (INIS)

    Rojas S, Ximena

    1995-01-01

    In order to optimize the Neutron-Activation Analysis (NAA) technique currently carried out in our country, the present work was carried out in the United States where irradiations with epithermal neutrons and a Compton suppression system were used, which allowed the characterization of aerosols of the city of Santiago de Chile. With this purpose, 54 filters of polycarbonate membranes were analysed with aerosols collected in an area of the capital during Spring 1993 and Winter of 1994. As a result, an improvement in the detection limits was observed, specially in elements such as Ni and Zn, which are not easily detectable through NAA. The application of both systems also permits the usage of this technique in geological and biological samples, where the presence of Na, Al and Cl obstruct the determination of some elements. The determined elements in both fractions were Mn, V, Cu, As, Sb, Co, Br, Cl, Ni, Zn, Ca, Al, Na and Fe. (author). 8 refs., 7 figs., 9 tabs

  4. Epithermal neutron activation analysis of blue-green algae Spirulina Platensis as a matrix for selenium-containing pharmaceuticals

    International Nuclear Information System (INIS)

    Mosulishvili, L.M.; Kirkesali, E.I.; Belokobyl'skij, A.I.; Khizanishvili, A.I.; Frontas'eva, M.V.; Gundorina, S.F.; Oprea, C.D.

    2000-01-01

    To evaluate the potentiality of the blue-green algae Spirulina Platensis as a matrix for the production of Se-containing pharmaceuticals, the background levels of 31 major, minor and trace elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Cr, Mn, Fe, Co, Ni (using (n,p)-reaction), As, Br, Zn, Rb, Mo, Ag, Sb, I, Ba, Sm, Tb, Tm, Hf, Ta, W, Au, Hg, Th) in Spirulina Platensis biomass were determined by means of epithermal neutron activation analysis. The possibility of the purpose-oriented incorporation of Se into Spirulina Platensis biomass was demonstrated. The polynomial dependence of the Se accumulation on nutritional medium loading was revealed. The employed analytical technique allows one to reliably control the amount of toxic elements in algae Spirulina Platensis. Based on this study, a conclusion of the possibility to use Spirulina Platensis as a matrix for the production of Se-containing pharmaceuticals was drawn

  5. Boron neutron capture therapy (BNCT) for glioblastoma multiforme using the epithermal neutron beam at the Brookhaven Medical Research Reactor

    International Nuclear Information System (INIS)

    Capala, J.; Diaz, A.Z.; Chadha, M.

    1997-01-01

    The abstract describes evaluation of boron neutron capture therapy (BNCT) for two groups of glioblastoma multiforme patients. From September 1994 to February 1996 15 patients have been treated. In September 1997 another 34 patients were examined. Authors determined a safe starting dose for BNCT using epithermal neutrons and BPA-F. They have also evaluated adverse effects of BNCT at this starting dose. Therapeutic effectiveness of this starting dose has been evaluated. No significant side effects from BPA-F infusion or BNCT treatment were observed in normal brains

  6. Boron neutron capture therapy (BNCT) for glioblastoma multiforme using the epithermal neutron beam at the Brookhaven Medical Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Capala, J. [Brookhaven National Lab., Upton, NY (United States); Diaz, A.Z.; Chadha, M. [Univ. Hospital, State Univ. of New York, NY (United States)] [and others

    1997-12-31

    The abstract describes evaluation of boron neutron capture therapy (BNCT) for two groups of glioblastoma multiforme patients. From September 1994 to February 1996 15 patients have been treated. In September 1997 another 34 patients were examined. Authors determined a safe starting dose for BNCT using epithermal neutrons and BPA-F. They have also evaluated adverse effects of BNCT at this starting dose. Therapeutic effectiveness of this starting dose has been evaluated. No significant side effects from BPA-F infusion or BNCT treatment were observed in normal brains.

  7. Method and apparatus for epithermal neutron decay logging

    International Nuclear Information System (INIS)

    Nelligan, W.B.

    1998-01-01

    The nature of hydrogenous fluids filling the pore spaces in formations surrounding a well bore are determined by irradiating the formations with bursts of high energy neutrons and using the ratio of time-dependent parameters related to the decay of epithermal neutron populations above two different energy levels to provide values indicative of the kind of fluid present, independent of porosity. The measurement above the higher of these energy levels, appr. 0.4eV, indicates the existence of hydrogenous fluid, water and hydrocarbons in the formations. The lower threshold measurement, above appr. 0.15eV, is indicative of the structure of the molecule in which the hydrogen molecule is bound and of the porosity. A pulsed neutron generator in a sonde irradiates the formations with 14meV neutrons and a pair of detectors, one shielded by cadmium, to establish the 0.4eV threshold energy level and the other, shielded by gadolinium, to establish the 0.15eV threshold energy level. Time related parameters of the count rate information, e.g. the decay constants, provided by each detector are derived. The ratio of the respective parameters is used to identify the type of fluid in the information, independent of porosity. The method and apparatus can determine water saturation, i.e. percentage of water in the formation fluid and can identify specific types of hydrocarbons under 100% hydrocarbon saturation conditions. 8 figs

  8. Combination of epithermal and inelastic neutron scattering methods to locate coal and oil-shale zones

    International Nuclear Information System (INIS)

    Schultz, W.E.

    1976-01-01

    A pulsed neutron generator of the deuterium-tritium reaction type irradiates earth formations in the vicinity of a borehole with 14 MeV neutrons. Gamma rays produced by the inelastic scattering of the fast neutrons are observed in four energy regions of the gamma ray energy spectrum corresponding to the inelastic scattering of neutrons by carbon, oxygen, silicon, and calcium. The carbon/oxygen, calcium/silicon, and carbon plus oxygen gamma rays are found and combined with a separately derived hydrogen index log to determine the quality of coal-bearing formations or oil-shale regions. The hydrogen index curve is found preferably by a dual-spaced detector epithermal neutron porosity logging technique or from a conventional thermal neutron gamma ray log

  9. In vitro biological effectiveness of JRR-4 epithermal neutron beam. Experiment under free air beam and in water phantom. Cooperative research

    International Nuclear Information System (INIS)

    Yamamoto, Tetsuya; Matsumura, Akira; Nose, Tadao; Yamamoto, Kazuyoshi; Kumada, Hiroaki; Kishi, Toshiaki; Hori, Naohiko; Torii, Yoshiya; Horiguchi, Yoji

    2002-05-01

    The surviving curve and the biological effectiveness factor of dose components generated in boron neutron capture therapy (BNCT) were separately determined in neutron beams at Japan Research Reactor No.4. Surviving fraction of V79 Chinese hamster cell with or without 10 B was obtained using an epithermal neutron beam (ENB), a mixed thermal-epithermal neutron beam (TNB-1), and a thermal neutron beam (TNB-2), which were used or planned to use for BNCT clinical trial. The cell killing effect of these neutron beams with or without the presence of 10 B depended highly on the neutron beam used, according to the epithermal and fast neutron content in the beam. The biological effectiveness factor values of the boron capture reaction for ENB, TNB-1 and TNB-2 were 3.99±0.24, 3.04±0.19 and 1.43±0.08, respectively. The biological effectiveness factor values of the high-LET dose components based on the hydrogen recoils and the nitrogen capture reaction were 2.50±0.32, 2.34±0.30 and 2.17±0.28 for ENB, TNB-1 and TNB-2, respectively. The biological effectiveness factor values of the neutron and photon components were 1.22±0.16, 1.23±0.16 and 1.21±0.16, respectively. The depth function of biological effectiveness factor in water phantom and the difference in biological effectiveness factor among boron compounds were also determined. The experimental determination of biological effectiveness factor outlined in this paper is applicable to the dose calculation for each dose component of the neutron beams and contribute to an accurate biological effectiveness factor as comparison with a neutron beam at a different facility employed in ongoing and planned BNCT clinical trials. (author)

  10. Neutron activation analysis in Romania

    International Nuclear Information System (INIS)

    Apostolescu, St.

    1985-01-01

    The following basic nuclear facilities are used for neutron activation analysis: a 2000 KW VVR-S Nuclear Reactor, a U-200 Cyclotron, a 30 MeV Betatron, several 14 MeV neutron generators and a king size High Voltage tandem Van de'Graaff accelerator. The main domains of application of the thermal neutron activation analysis are: geology and mining, processing of materials, environment and biology, achaeology. Epithermal neutron activation analysis has been used for determination of uranium and thorium in ores with high Th/U ratios or high rare earth contents. One low energy accelerator, used as 14.1 Mev neutron source, is provided with special equipmen for oxigen and low mass elements determination. An useful alternating way to support fast neutron activation analysis is an accurate theoretical description of the fast neutron induced reactions based on the statistical model (Hauser-Feubach STAPRE code) and the preequilibrium decay geometry dependent model. A gravitational sample changer has been installed at the end of a beam line of the Cyclotron, which enables to perform charged particles activation analysis for protein determination in grains

  11. ESR-dosimetry in thermal and epithermal neutron fields for application in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, Tobias

    2016-01-22

    Dosimetry is essential for every form of radiotherapy. In Boron Neutron Capture Therapy (BNCT) mixed neutron and gamma fields have to be considered. Dose is deposited in different neutron interactions with elements in the penetrated tissue and by gamma particles, which are always part of a neutron field. The therapeutic dose in BNCT is deposited by densely ionising particles, originating from the fragmentation of the isotope boron-10 after capture of a thermal neutron. Despite being investigated for decades, dosimetry in neutron beams or fields for BNCT remains complex, due to the variety in type and energy of the secondary particles. Today usually ionisation chambers combined with metal foils are used. The applied techniques require extensive effort and are time consuming, while the resulting uncertainties remain high. Consequently, the investigation of more effective techniques or alternative dosimeters is an important field of research. In this work the possibilities of ESR-dosimeters in those fields have been investigated. Certain materials, such as alanine, generate stable radicals upon irradiation. Using Electron Spin Resonance (ESR) spectrometry the amount of radicals, which is proportional to absorbed dose, can be quantified. Different ESR detector materials have been irradiated in the thermal neutron field of the research reactor TRIGA research reactor in Mainz, Germany, with five setups, generating different secondary particle spectra. Further irradiations have been conducted in two epithermal neutron beams. The detector response, however, strongly depends on the dose depositing particle type and energy. It is hence necessary to accompany measurements by computational modelling and simulation. In this work the Monte Carlo code FLUKA was used to calculate absorbed doses and dose components. The relative effectiveness (RE), linking absorbed dose and detector response, has been calculated using amorphous track models. For the simulation, detailed models of

  12. The Measurement of Epithermal-to-Thermal U-238 Neutron Capture Rate in Aagesta Power Reactor Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Bernander, G

    1967-09-15

    The epithermal-to-thermal neutron capture rate ratio {rho}{sub 28} in U-238 in Aagesta fuel has been measured by the chemical separation method. The method involves the isolation of Np-239 from uranium and fission products by reversed phase partition chromatography. Although somewhat elaborate, and in spite of difficulties with residual fission products, the method has yielded reasonably accurate results. Further development work on chemical procedures may lead to some improvement. A comparison with the coincidence method - electronic separation of activities - has not shown any large systematic differences between the two methods. The separation of the epithermal U-235 activation from the total has been achieved by means of the '1/v subtraction technique' using copper foils as the 1/v monitor. The complementary thermal column irradiations required have been performed in the research reactors TRIGA (Helsinki) and R1 (Stockholm). From the measured {rho}{sub 28} values the resonance escape probability (p) and the initial conversion ratio (ICR) may be calculated using cross-section data and other lattice parameters. Comparisons with theoretical values of {rho} and ICR as calculated with the BURNUP lattice parameter code are favourable.

  13. SPLET - A program for calculating the space-lethargy distribution of epithermal neutrons in a reactor lattice cell

    International Nuclear Information System (INIS)

    Matausek, M.V.; Zmijatevic, I.

    1981-01-01

    A procedure to solve the space-single-lethargy dependent transport equation for epithermal neutrons in a cylindricised multi-region reactor lattice cell has been developed and proposed in the earlier papers. Here, the computational algorithm is comprised and the computing program SPLET, which calculates the space-lethargy distribution of the spherical harmonics neutron flux moments, as well as the related integral quantities as reaction rates and resonance integrals, is described. (author)

  14. The alanine detector in BNCT dosimetry: dose response in thermal and epithermal neutron fields.

    Science.gov (United States)

    Schmitz, T; Bassler, N; Blaickner, M; Ziegner, M; Hsiao, M C; Liu, Y H; Koivunoro, H; Auterinen, I; Serén, T; Kotiluoto, P; Palmans, H; Sharpe, P; Langguth, P; Hampel, G

    2015-01-01

    The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different neutron beams to explore the alanine dose response behavior and to validate model predictions. Additionally, application in medical neutron fields for boron neutron capture therapy is discussed. Alanine detectors have been irradiated in the thermal neutron field of the research reactor TRIGA Mainz, Germany, in five experimental conditions, generating different secondary particle spectra. Further irradiations have been made in the epithermal neutron beams at the research reactors FiR 1 in Helsinki, Finland, and Tsing Hua open pool reactor in HsinChu, Taiwan ROC. Readout has been performed with electron spin resonance spectrometry with reference to an absorbed dose standard in a (60)Co gamma ray beam. Absorbed doses and dose components have been calculated using the Monte Carlo codes fluka and mcnp. The relative effectiveness (RE), linking absorbed dose and detector response, has been calculated using the Hansen & Olsen alanine response model. The measured dose response of the alanine detector in the different experiments has been evaluated and compared to model predictions. Therefore, a relative effectiveness has been calculated for each dose component, accounting for its dependence on particle type and energy. Agreement within 5% between model and measurement has been achieved for most irradiated detectors. Significant differences have been observed in response behavior between thermal and epithermal neutron fields, especially regarding dose composition and depth dose curves. The calculated dose components could be verified with the experimental results in the different primary and secondary particle fields. The alanine detector can be used without

  15. Spherical Harmonics Treatment of Epithermal Neutron Spectra in Reactor lattices

    International Nuclear Information System (INIS)

    Matausek, M.V.

    1972-04-01

    A procedure has been developed to solve the slowing down transport equation for neutrons in a cylindrized reactor lattice cell. Treating the anisotropy of the epithermal neutron flux by the spherical harmonics formalism, which reduces the space-angle-lethargy-dependent transport equation to the matrix integrodifferential equation in space and lethargy, and replacing the lethargy transfer integrals by finite-difference forms, a set of matrix ordinary differential equations, with lethargy and space dependent coefficients, is obtained. In the resonance region this set takes a lower block triangular form and can be directly solved by forward block substitution; in the lethargy range, where the fast fission effects have to be considered, the iterative procedure is introduced. A simple and efficient approximation is then proposed, making possible the analytical solution for the spatial dependence of the spherical harmonics flux moments. The proposed procedure has been numerically examined and approved. Some typical results are presented and discussed. (author)

  16. Absolute instrumental neutron activation analysis at Lawrence Livermore Laboratory

    International Nuclear Information System (INIS)

    Heft, R.E.

    1977-01-01

    The Environmental Science Division at Lawrence Livermore Laboratory has in use a system of absolute Instrumental Neutron Activation Analysis (INAA). Basically, absolute INAA is dependent upon the absolute measurement of the disintegration rates of the nuclides produced by neutron capture. From such disintegration rate data, the amount of the target element present in the irradiated sample is calculated by dividing the observed disintegration rate for each nuclide by the expected value for the disintegration rate per microgram of the target element that produced the nuclide. In absolute INAA, the expected value for disintegration rate per microgram is calculated from nuclear parameters and from measured values of both thermal and epithermal neutron fluxes which were present during irradiation. Absolute INAA does not depend on the concurrent irradiation of elemental standards but does depend on the values for thermal and epithermal neutron capture cross-sections for the target nuclides. A description of the analytical method is presented

  17. Radiobiology studies for the evaluation of epithermal neutron beams used for BNCT

    International Nuclear Information System (INIS)

    Green, S.; Jones, B.; Mill, A.J.

    2006-01-01

    This paper outlines our plans for a study to establish the radiobiological effectiveness of the various mixes of radiation components present in an epithermal neutron beam designed for BNCT and to incorporate these data into clinical protocols for the treatment of malignant glioma. This is a description of work which is funded and just now beginning in Birmingham so no results can be presented. Our project will involve a combination of experimental measurements carried out in Birmingham and in Boston and mathematical modelling carried out in Birmingham. Despite all the extant in-vitro and in-vivo work, there is no widely accepted method to determine biological effect by accounting for variations in beam component mix, dose rate and treatment fractionation for disparate from the various BNCT centres. The objectives of this study are: To develop a cell-based radiobiology protocol to provide essential data on safety and efficacy of beams for Boron Neutron Capture Therapy (BNCT) in advance of clinical trials. To exploit the facilities at Massachusetts Institute of Technology for variable dose-rate epithermal irradiations to validate the above protocol. To develop mathematical models of this radiobiological system that can be used to inform decisions on dose selection, fractionation schedules, BNCT use as supplementary boosts or for re-treatment of recurrent cancers. To provide fundamental data relevant to the understanding of the radiobiology of simultaneous mixed high-and low-LET radiations over a clinically relevant dose-range. (author)

  18. The resonant detector and its application to epithermal neutron spectroscopy

    International Nuclear Information System (INIS)

    Gorini, G.; Perelli-Cippo, E.; Tardocchi, M.; Andreani, C.; D'Angelo, A.; Pietropaolo, A.; Senesi, R.; Imberti, S.; Bracco, A.; Previtali, E.; Pessina, G.; Rhodes, N.J.; Schooneveld, E.M.

    2004-01-01

    New perspectives for epithermal neutron spectroscopy are being opened by the development of the resonant detector (RD) and its use on inverse geometry time of flight spectrometers at spallation sources. The RD was first proposed in the 1980s and was recently brought to a performance level exceeding conventional neutron-sensitive Li-glass scintillator detectors. It features a photon counter coupled to a neutron analyzer foil. Resonant neutron absorption in the foil results in the emission of prompt gamma rays that are detected in the photon counter. The dimensions of the RD set the spatial resolution that can be achieved, ranging from a fraction of a cm to several cm. It can thus be tailored to the construction of detector arrays of different geometry. The main results of the research on this kind of detector are reported leading to the present optimized RD design based on a combination of YAP scintillation photon counter and uranium or gold analyzer foils. This detector has already been selected for application in the upgrade of the VESUVIO spectrometer on ISIS. A special application is the Very Low Angle Detector (VLAD) bank, which will extend the kinematical region for neutron scattering to low momentum transfer ( -1 ) whilst still keeping energy transfer >1 eV, thus allowing new experimental studies in condensed matter systems. The first results of tests made with prototype VLAD detectors are presented, confirming the usefulness of the RD for measurements at scattering angles as low as 2-5 deg

  19. Thermal and epithermal neutron fluence rate gradient measurements by PADC detectors in LINAC radiotherapy treatments-field

    Energy Technology Data Exchange (ETDEWEB)

    Barrera, M. T., E-mail: mariate9590@gmail.com; Barros, H.; Pino, F.; Sajo-Bohus, L. [Universidad Simón Bolívar, Nuclear Physics Laboratory, Sartenejas, Caracas (Venezuela, Bolivarian Republic of); Dávila, J. [Física Médica C. A. and Universidad Central de Venezuela, Caracas (Venezuela, Bolivarian Republic of)

    2015-07-23

    LINAC VARIAN 2100 is where energetic electrons produce Bremsstrahlung radiation, with energies above the nucleon binding energy (E≈5.5MeV). This radiation induce (γ,n) and (e,e’n) reactions mainly in the natural tungsten target material (its total photoneutron cross section is about 4000 mb in a energy range from 9-17 MeV). These reactions may occur also in other components of the system (e.g. multi leaf collimator). During radiation treatment the human body may receive an additional dose inside and outside the treated volume produced by the mentioned nuclear reactions. We measured the neutron density at the treatment table using nuclear track detectors (PADC-NTD). These covered by a boron-converter are employed, including a cadmium filter, to determine the ratio between two groups of neutron energy, i.e. thermal and epithermal. The PADC-NTD detectors were exposed to the radiation field at the iso-center during regular operation of the accelerator. Neutron are determined indirectly by the converting reaction {sup 10}B(n,α){sup 7}Li the emerging charged particle leave their kinetic energy in the PADC forming a latent nuclear track, enlarged by chemical etching (6N, NaOH, 70°C). Track density provides information on the neutron density through calibration coefficient (∼1.6 10{sup 4} neutrons /track) obtained by a californium source. We report the estimation of the thermal and epithermal neutron field and its gradient for photoneutrons produced in radiotherapy treatments with 18 MV linear accelerators. It was obsered that photoneutron production have higher rate at the iso-center.

  20. Pulse neutron logging technique

    International Nuclear Information System (INIS)

    Bespalov, D.F.; Dylyuk, A.A.

    1975-01-01

    A new method of neutron-burst logging is proposed, residing in irradiating rocks with fast neutron bursts and registering the integrated flux burst of thermal and/or epithermal neutrons, from the moment of its initiation to that of full absorption. The obtaained value is representative of the rock properties (porosity, hydrogen content). The integrated flux in a burst of thermal and epithermal neutrons can be measured both by way of activation of a reference sample of a known chemical composition during the neutron burst and by recording the radiation of induced activity of the sample within an interval between two bursts. The proposed method features high informative value, accuracy and efficiency

  1. Comparison of Cadmium-Zinc-Telluride semiconductor and Yttrium-Aluminum-Perovskite scintillator as photon detectors for epithermal neutron spectroscopy

    International Nuclear Information System (INIS)

    Tardocchi, M.; Pietropaolo, A.; Andreani, C.; Gorini, G.; Imberti, S.; Perelli-Cippo, E.; Senesi, R.; Rhodes, N.; Schooneveld, E.M.

    2006-01-01

    The range of applications of epithermal neutron scattering experiments has been recently extended by the development of the Resonance Detector. In a Resonance Detector, resonant neutron absorption in an analyzer foil results in prompt emission of X- and γ-rays which are detected by a photon counter. Several combinations of analyzer foils and photon detectors have been studied and tested over the years and best results have been obtained with the combination of a natural uranium and (i) Cadmium-Zinc-Telluride (CZT) semiconductor (ii) Yttrium-Aluminum-Perovskite (YAP) scintillators. Here we compare the performance of the CZT semiconductor and YAP scintillator as Resonance Detector units. Two Resonance Detector prototypes made of natural uranium foil viewed by CZT and YAP were tested on the VESUVIO spectrometer at the ISIS spallation neutron source. The results show that both YAP and CZT can be used to detect epithermal neutrons in the energy range from 1 up to 66 eV. It was found that the signal-to-background ratio of the measurement can significantly be improved by raising the lower level discrimination threshold on the γ energy to about 600 keV. The advantages/disadvantages of the choice of a Resonance Detector based on YAP or CZT are discussed together with some potential applications

  2. Epithermal neutron flux distribution and its impact on (n, γ) activation analysis result

    International Nuclear Information System (INIS)

    Jovanovich, S.; Pukotich, P.; Zejnilovich, R.; Corte, F. de; Moens, L.; Hoste, J.; Simonitis, A.

    1985-01-01

    The differences are discussed between the simplified model, introduced to derive the generally accepted ideal 1/E - law, and the conditions existing in an actual reactor. For absolute and comparator types of (n, γ) activation analysis (NAA), the semiempirical 1/Esup(1+α) form is a better approximation - necessary to introduce, but sufficient for practical purposes. Parameter α, being a measure of the epithermal nonideality, is a characteristics of the reactor site. The impact of this nonideality on NAA result is outlined, together with the method for appropriate correction

  3. The Measurement of Epithermal-to-Thermal U-238 Neutron Capture Rate (ρ28) in Aagesta Power Reactor Fuel

    International Nuclear Information System (INIS)

    Bernander, G.

    1967-09-01

    The epithermal-to-thermal neutron capture rate ratio ρ 28 in U-238 in Aagesta fuel has been measured by the chemical separation method. The method involves the isolation of Np-239 from uranium and fission products by reversed phase partition chromatography. Although somewhat elaborate, and in spite of difficulties with residual fission products, the method has yielded reasonably accurate results. Further development work on chemical procedures may lead to some improvement. A comparison with the coincidence method - electronic separation of activities - has not shown any large systematic differences between the two methods. The separation of the epithermal U-235 activation from the total has been achieved by means of the '1/v subtraction technique' using copper foils as the 1/v monitor. The complementary thermal column irradiations required have been performed in the research reactors TRIGA (Helsinki) and R1 (Stockholm). From the measured ρ 28 values the resonance escape probability (p) and the initial conversion ratio (ICR) may be calculated using cross-section data and other lattice parameters. Comparisons with theoretical values of ρ and ICR as calculated with the BURNUP lattice parameter code are favourable

  4. Initial Experimental Verification of the Neutron Beam Modeling for the LBNL BNCT Facility

    International Nuclear Information System (INIS)

    Bleuel, D.L.; Chu, W.T.; Donahue, R.J.; Ludewigt, B.A.; McDonald, R.J.; Smith, A.R.; Stone, N.A.; Vuji, J.

    1999-01-01

    In preparation for future clinical BNCT trials, neutron production via the 7Li(p,n) reaction as well as subsequent moderation to produce epithermal neutrons have been studied. Proper design of a moderator and filter assembly is crucial in producing an optimal epithermal neutron spectrum for brain tumor treatments. Based on in-phantom figures-of-merit,desirable assemblies have been identified. Experiments were performed at the Lawrence Berkeley National Laboratory's 88-inch cyclotron to characterize epithermal neutron beams created using several microampere of 2.5 MeV protons on a lithium target. The neutron moderating assembly consisted of Al/AlF3 and Teflon, with a lead reflector to produce an epithermal spectrum strongly peaked at 10-20 keV. The thermal neutron fluence was measured as a function of depth in a cubic lucite head phantom by neutron activation in gold foils. Portions of the neutron spectrum were measured by in-air activation of six cadmium-covered materials (Au, Mn, In, Cu, Co, W) with high epithermal neutron absorption resonances. The results are reasonably reproduced in Monte Carlo computational models, confirming their validity

  5. Manual for the Epithermal Neutron Multiplicity Detector (ENMC) for Measurement of Impure MOX and Plutonium Samples

    International Nuclear Information System (INIS)

    Menlove, H. O.; Rael, C. D.; Kroncke, K. E.; DeAguero, K. J.

    2004-01-01

    We have designed a high-efficiency neutron detector for passive neutron coincidence and multiplicity counting of dirty scrap and bulk samples of plutonium. The counter will be used for the measurement of impure plutonium samples at the JNC MOX fabrication facility in Japan. The counter can also be used to create working standards from bulk process MOX. The detector uses advanced design "3He tubes to increase the efficiency and to shorten the neutron die-away time. The efficiency is 64% and the die-away time is 19.1 ?s. The Epithermal Neutron Multiplicity Counter (ENMC) is designed for high-precision measurements of bulk plutonium samples with diameters of less than 200 mm. The average neutron energy from the sample can be measured using the ratio of the inner ring of He-3 tubes to the outer ring. This report describes the hardware, performance, and calibration for the ENMC.

  6. Microscopic cross-section measurements by thermal neutron activation

    International Nuclear Information System (INIS)

    Avila L, J.

    1987-08-01

    Microscopic cross sections measured by thermal neutron activation using RP-0 reactor at the Peruvian Nuclear Energy Institute. The method consists in measuring microscopic cross section ratios through activated samples, requiring being corrected in thermal and epithermal energetic range by Westcott formalism. Furthermore, the comptage ratios measured for each photopeak to its decay fraction should be normalized from interrelation between both processes above, activation microscopic cross sections are obtained

  7. Development of new instrumentation for epithermal neutron scattering at very low angles

    International Nuclear Information System (INIS)

    Tardocchi, M.; Pietropaolo, A.; Andreani, C.; Gorini, G.; Perelli-Cippo, E.; Rhodes, N.J.; Schooneveld, E.M.; Senesi, R.

    2004-01-01

    New perspectives for epithermal neutron spectroscopy are opened up by the recent developments of Resonance Detectors (RD) for inverse geometry time-of-flight spectrometers at pulsed neutron sources. The RD is based on the combination of an analyser foil used as neutron-to-gamma converter and a suitable photon detector. Here, we report on the state of the RD which is based on a YAP scintillator viewing a natural uranium analyser foil. The response of the YAP detector to the radiative capture γ emission from the uranium analyser foil has been characterized with a bi-parametric measurement of a reference Pb sample, which allowed simultaneous measurements of both neutron time-of-flight and γ pulse height (energy) spectra. The analysis of the γ pulse height and neutron time-of-flight spectra permitted to identify the signal and background components. These measurements showed that a significant improvement in the signal-to-background ratio can be achieved by setting a lower level discrimination on the photon energy at about 600keV. The first application of RD is the Very Low Angle Detector Bank (VLAD) which is planned to be installed in the next three years as an upgrade of the VESUVIO spectrometer, at the ISIS pulsed neutron source. VLAD will extend the (q,ω) kinematical to low wave vector transfers (q10A-1) coupled to high-energy transfers (-bar ω>1eV), which is still unexplored by neutron scattering experiments. The first measurements obtained on an ice sample with a VLAD prototype consisting of four RD units are presented here

  8. Development of new instrumentation for epithermal neutron scattering at very low angles

    Energy Technology Data Exchange (ETDEWEB)

    Tardocchi, M. [INFM, UdR Milano-Bicocca and Dipartimento di Fisica ' G.Occhialini' , Universita degli Studi di Milano-Bicocca, Pizza Della Scienza 3, Milan 20126 (Italy)]. E-mail: marco.tardocchi@mib.infn.it; Pietropaolo, A. [Dipartimento di Fisica, Universita degli Studi di Roma Tor Vergata and INFM, UdR Roma Tor Vergata, Rome (Italy); Andreani, C. [Dipartimento di Fisica, Universita degli Studi di Roma Tor Vergata and INFM, UdR Roma Tor Vergata, Rome (Italy); Gorini, G. [INFM, UdR Milano-Bicocca and Dipartimento di Fisica ' G.Occhialini' , Universita degli Studi di Milano-Bicocca, Pizza Della Scienza 3, Milan 20126 (Italy); Perelli-Cippo, E. [INFM, UdR Milano-Bicocca and Dipartimento di Fisica ' G.Occhialini' , Universita degli Studi di Milano-Bicocca, Pizza Della Scienza 3, Milan 20126 (Italy); Rhodes, N.J. [Isis Facility, Rutherford Appleton Laboratory, Chilton, Didcot (United Kingdom); Schooneveld, E.M. [Isis Facility, Rutherford Appleton Laboratory, Chilton, Didcot (United Kingdom); Senesi, R. [Dipartimento di Fisica, Universita degli Studi di Roma Tor Vergata and INFM, UdR Roma Tor Vergata, Rome (Italy)

    2004-12-11

    New perspectives for epithermal neutron spectroscopy are opened up by the recent developments of Resonance Detectors (RD) for inverse geometry time-of-flight spectrometers at pulsed neutron sources. The RD is based on the combination of an analyser foil used as neutron-to-gamma converter and a suitable photon detector. Here, we report on the state of the RD which is based on a YAP scintillator viewing a natural uranium analyser foil. The response of the YAP detector to the radiative capture {gamma} emission from the uranium analyser foil has been characterized with a bi-parametric measurement of a reference Pb sample, which allowed simultaneous measurements of both neutron time-of-flight and {gamma} pulse height (energy) spectra. The analysis of the {gamma} pulse height and neutron time-of-flight spectra permitted to identify the signal and background components. These measurements showed that a significant improvement in the signal-to-background ratio can be achieved by setting a lower level discrimination on the photon energy at about 600keV. The first application of RD is the Very Low Angle Detector Bank (VLAD) which is planned to be installed in the next three years as an upgrade of the VESUVIO spectrometer, at the ISIS pulsed neutron source. VLAD will extend the (q,{omega}) kinematical to low wave vector transfers (q10A-1) coupled to high-energy transfers (-bar {omega}>1eV), which is still unexplored by neutron scattering experiments. The first measurements obtained on an ice sample with a VLAD prototype consisting of four RD units are presented here.

  9. Intraoperative boron neutron capture therapy for malignant gliomas. First clinical results of Tsukuba phase I/II trial using JAERI mixed thermal-epithermal beam

    International Nuclear Information System (INIS)

    Matsumura, A.; Yamamoto, T.; Shibata, Y.

    2000-01-01

    Since October 1999, a clinical trial of intraoperative boron neutron capture therapy (IOBNCT) is in progress at JRR-4 (Japan Research Reactor-4) in Japan Atomic Energy Research Institute (JAERI) using mixed thermal-epithermal beam (thermal neutron beam I: TNB-I). Compared to pure thermal beam (thermal neutron beam II: TNB-II), TNB-I has an improved neutron delivery into the deep region than TNB-II. The clinical protocol and the preliminary results will be discussed. (author)

  10. Shielding design of a treatment room for an accelerator-based epithermal neutron irradiation facility for BNCT

    International Nuclear Information System (INIS)

    Evans, J.F.; Blue, T.E.

    1996-01-01

    Protecting the facility personnel and the general public from radiation exposure is a primary safety concern of an accelerator-based epithermal neutron irradiation facility. This work makes an attempt at answering the questions open-quotes How much?close quotes and open-quotes What kind?close quotes of shielding will meet the occupational limits of such a facility. Shielding effectiveness is compared for ordinary and barytes concretes in combination with and without borated polyethylene. A calculational model was developed of a treatment room, patient open-quotes scatterer,close quotes and the epithermal neutron beam. The Monte Carlo code, MCNP, was used to compute the total effective dose equivalent rates at specific points of interest outside of the treatment room. A conservative occupational effective dose rate limit of 0.01 mSv h -1 was the guideline for this study. Conservative Monte Carlo calculations show that constructing the treatment room walls with 1.5 m of ordinary concrete, 1.2 m of barytes concrete, 1.0 m of ordinary concrete preceded by 10 cm of 5% boron-polyethylene, or 0.8 m of barytes concrete preceded by 10 cm of 5% boron-polyethylene will adequately protect facility personnel. 20 refs., 8 figs., 2 tabs

  11. Calculations of neutron spectra after neutron-neutron scattering

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, B E [Gettysburg College, Box 405, Gettysburg, PA 17325 (United States); Stephenson, S L [Gettysburg College, Box 405, Gettysburg, PA 17325 (United States); Howell, C R [Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Mitchell, G E [North Carolina State University, Raleigh, NC 27695-8202 (United States); Tornow, W [Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Furman, W I [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Lychagin, E V [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Muzichka, A Yu [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Nekhaev, G V [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Strelkov, A V [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Sharapov, E I [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Shvetsov, V N [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation)

    2004-09-01

    A direct neutron-neutron scattering length, a{sub nn}, measurement with the goal of 3% accuracy (0.5 fm) is under preparation at the aperiodic pulsed reactor YAGUAR. A direct measurement of a{sub nn} will not only help resolve conflicting results of a{sub nn} by indirect means, but also in comparison to the proton-proton scattering length, a{sub pp}, shed light on the charge-symmetry of the nuclear force. We discuss in detail the analysis of the nn-scattering data in terms of a simple analytical expression. We also discuss calibration measurements using the time-of-flight spectra of neutrons scattered on He and Ar gases and the neutron activation technique. In particular, we calculate the neutron velocity and time-of-flight spectra after scattering neutrons on neutrons and after scattering neutrons on He and Ar atoms for the proposed experimental geometry, using a realistic neutron flux spectrum-Maxwellian plus epithermal tail. The shape of the neutron spectrum after scattering is appreciably different from the initial spectrum, due to collisions between thermal-thermal and thermal-epithermal neutrons. At the same time, the integral over the Maxwellian part of the realistic scattering spectrum differs by only about 6 per cent from that of a pure Maxwellian nn-scattering spectrum.

  12. Reactor AQUILON. The hardening of neutron spectrum in natural uranium rods, with a computation of epithermal fissions (1961); Pile AQUILON. Durcissement du spectre des neutrons dans les barreaux d'uranium et calcul des fissions epithermiques (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Durand -Smet, R; Lourme, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    - Microscopic flux measurements in reactor Aquilon have allowed to investigate the thermal and epithermal flux distribution in natural uranium rods, then to obtain the neutron spectrum variations in uranium, Wescott '{beta}' term of the average spectrum in the rod, and the ratio of epithermal to therma fissions. A new definition for the infinite multiplication factor is proposed in annex, which takes into account epithermal parameters. (authors) [French] - Un certain nombre de mesures effectuees dans la pile Aquilon ont permis d'etablir la distribution fine des flux thermique et epithermique dans les barreaux d'uranium, et d'en deduire les variations du spectre des neutrons dans l'uranium, le terme {beta} du spectre de Wescott moyen dans le barreau et le nombre de fissions epithermiques. En annexe, il est propose une definition nouvelle du coefficient de multiplication infini, qui fait intervenir les parametres epithermiques. (auteurs)

  13. The orientation effect in the activities of neutronic probes; Efecto de orientacion en las actividades de sondas neutronicas

    Energy Technology Data Exchange (ETDEWEB)

    Vigon, M A

    1956-07-01

    The formulae relating activity and position of a neutron irradiated Indium foil, have been verified experimentally. Measurements with both thin and thick foils for epithermal neutrons and with thick foils for thermal neutrons have been carried out. The experimental results agree qualitatively with the theoretical predictions. (Author)

  14. Pulsed neutron porosity logging system

    International Nuclear Information System (INIS)

    Smith, H.D. Jr.; Smith, M.P.; Schultz, W.E.

    1978-01-01

    An improved pulsed neutron porosity logging system is provided in the present invention. A logging tool provided with a 14 MeV pulsed neutron source, an epithermal neutron detector, and a fast neutron detector is moved through a borehole. Repetitive bursts of neutrons irradiate the earth formations and, during the bursts, the fast neutron population is sampled. During the interval between bursts the epithermal neutron population is sampled along with background gamma radiation due to lingering thermal neutrons. The fast and epithermal neutron population measurements are combined to provide a measurement of formation porosity

  15. Simulation study of the photon quality correction factors of ionization chambers for FiR 1 epithermal neutron beam

    International Nuclear Information System (INIS)

    Koivunoro, H.; Uusi-Simola, J.; Savolainen, S.; Kotiluoto, P.; Auterinen, I.; Kosunen, A.

    2006-01-01

    At FiR 1 BNCT facility in Finland, neutron-insensitive Mg(Ar) ionization chambers are used for photon dose measurements in an epithermal neutron beam. Previously, photon sensitivity factors for the chamber for the measurements in a water phantom in FiR 1 beam have been determined experimentally from measurements in 60 Co gamma and in a 6 MV clinical accelerator photon beams. However, the response of the ionization chamber in a water phantom depends on energy spectrum and angle of the photons and the secondary electrons created inside the phantom and may differ depending on type of the irradiation source (accelerator vs. an epithermal neutron beam). Also, the experimental sensitivity factor does not take into account the possible perturbations in the photon production in phantom caused by the ionization chamber materials. Therefore, it is necessary to determine the photon quality correction factors (k Qγ ) for the Mg(Ar) chamber at the FiR 1 beam through computer simulations. In this study, the k Qγ factors have been determined for Mg(Ar) chamber from Monte Carlo calculations of absorbed photon dose at two depths in a water phantom using MCNP code. The k qγ factors obtained with this method are compared to the sensitivity factors determined with measurements in an accelerator photon beam and to the k Qγ factors published previously. (author)

  16. An epithermal neutron source for BNCT based on an ESQ-accelerator

    International Nuclear Information System (INIS)

    Ludewigt, B.A.; Chu, W.T.; Donahue, R.J.; Kwan, J.; Phillips, T.L.; Reginato, L.L.; Wells, R.P.

    1997-07-01

    An accelerator-based BNCT facility is under development at the Lawrence Berkeley National Laboratory. Neutrons will be produced via the 7 Li(p,n) reaction at proton energies of about 2.5 MeV with subsequent moderation and filtering for shaping epithermal neutron beams for BNCT. Moderator, filter, and shielding assemblies have been modeled using MCNP. Head-phantom dose distributions have been calculated using the treatment planning software BNCT RTPE. The simulation studies have shown that a proton beam current of ∼ 20 mA is required to deliver high quality brain treatments in about 40 minutes. The results also indicate that significantly higher doses can be delivered to deep-seated tumors in comparison to the Brookhaven Medical Research Reactor beam. An electrostatic quadrupole (ESQ) accelerator is ideally suited to provide the high beam currents desired. A novel power supply utilizing the air-coupled transformer concept is under development. It will enable the ESQ-accelerator to deliver proton beam currents exceeding 50 mA. A lithium target has been designed which consists of a thin layer of lithium on an aluminum backing. Closely spaced, narrow coolant passages cut into the aluminum allow the removal of a 50kW heat-load by convective water cooling. The system under development is suitable for hospital installation and has the potential for providing neutron beams superior to reactor sources

  17. Multipurpose epithermal neutron beam on new research station at MARIA research reactor in Swierk-Poland

    Energy Technology Data Exchange (ETDEWEB)

    Gryzinski, M.A.; Maciak, M. [National Centre for Nuclear Research, Andrzeja Soltana 7, 05-400 Otwock-Swierk (Poland)

    2015-07-01

    MARIA reactor is an open-pool research reactor what gives the chance to install uranium fission converter on the periphery of the core. It could be installed far enough not to induce reactivity of the core but close enough to produce high flux of fast neutrons. Special design of the converter is now under construction. It is planned to set the research stand based on such uranium converter in the near future: in 2015 MARIA reactor infrastructure should be ready (preparation started in 2013), in 2016 the neutron beam starts and in 2017 opening the stand for material and biological research or for medical training concerning BNCT. Unused for many years, horizontal channel number H2 at MARIA research rector in Poland, is going to be prepared as a part of unique stand. The characteristics of the neutron beam will be significant advantage of the facility. High flux of neutrons at the level of 2x10{sup 9} cm{sup -2}s{sup -1} will be obtainable by uranium neutron converter located 90 cm far from the reactor core fuel elements (still inside reactor core basket between so called core reflectors). Due to reaction of core neutrons with converter U{sub 3}Si{sub 2} material it will produce high flux of fast neutrons. After conversion neutrons will be collimated and moderated in the channel by special set of filters and moderators. At the end of H2 channel i.e. at the entrance to the research room neutron energy will be in the epithermal energy range with neutron intensity at least at the level required for BNCT (2x10{sup 9} cm{sup -2}s{sup -1}). For other purposes density of the neutron flux could be smaller. The possibility to change type and amount of installed filters/moderators which enables getting different properties of the beam (neutron energy spectrum, neutron-gamma ratio and beam profile and shape) is taken into account. H2 channel is located in separate room which is adjacent to two other empty rooms under the preparation for research laboratories (200 m2). It is

  18. Neutron activation determination of impurities in molybdenum

    International Nuclear Information System (INIS)

    Usmanova, M.M.; Mukhamedshina, N.M.; Obraztsova, T.V.; Saidakhmedov, K.Kh.

    1984-01-01

    Instrumental neutron-activation techniques of impurity element determination in molybdenum and MoO 3 (solid and powdered samples) have been developed. When determining impurities of Na, K, Mn, Cu, W, Re molybdenum has been irradiated by thermal neutrons in reactor for 20 min, the sample mass constituted 200-300 mg, sample cooling time after irradiation - 2.5-3.5 h. It is shown that in the process of Cr, Fe, Co, Zn determination the samples should be irradiated with thermal neutrons, and in the process of Sb, Ta and Ni determination - with resonance and fast neutrons. Simultaneous determination of the elements during irradiation with neutrons with reactor spectrum is possible. When determining P and S the samples are irradiated with thermal and epithermal neutrons and β-activity of samples and comparison samples are measured using β-spectrometer with anthracene crystal. The techniques developed permit to determine impurities in Mo with a relative standard deviation 0.07-0.15 and lower boundaries of contents determined - 10 -4 - 10 -7 %

  19. Multi-element neutron activation analysis of Brazilian coal samples

    International Nuclear Information System (INIS)

    Atalla, L.T.; Requejo, C.S.

    1982-09-01

    The elements U, Th, La, Ce, Nd, Sm, Eu, Dy, Tb, Yb, Lu, Sc, Ta, Hf, Co, Ni, Cr, Mo, Ti, V, W, In, Ga, Mn, Ba, Sr, Mg, Rb, Cs, K, Cl, Br, As, Sb, Au, Ca, Al and Fe were determined in coal samples by instrumental neutron activation analysis, by using both thermal and epithermal neutron irradiations. The irradiation times were 10 minutes and 8 or 16 hours in a position where the thermal neutron flux was about 10 12 n.cm - 2 .s - 1 and 72 non-consecutive hours for epithermal irradiation at a flux of about 10 11 n.Cm - 2 .s - 1 . After the instrumental analysis of the above mentioned elements, Zn and Se were determined with chemical separation. The relative standard deviation of, at least, 4 determinations was about + - 10% for the majority of the results. The coal samples analysed were supplied by: Cia. Estadual da Tecnologia e Saneamento Basico (CETESB-SP), Cia. de Pesquisas e Lavras Minerais (COPELMI-RS), Cia. Carbonifera Urussunga (SC), Cia. Carbonifera Prospera (SC), Cia. Carbonifera Treviso (SC), Cia. Nacional de Mineracao de Carvao do Barro Branco (SC) and Comissao Nacional de Energia Nuclear (CNEN-RJ). (Author) [pt

  20. A neutron beam polarizer for study of parity violation in neutron-nucleus interactions

    International Nuclear Information System (INIS)

    Penttilae, S.I.; Bowman, J.D.; Delheij, P.P.; Frankle, C.M.; Haase, D.G.; Postma, H.; Seestrom, S.J.; Yen, Y.

    1995-01-01

    A dynamically-polarized proton target operating at 5 Tesla and 1 K has been built to polarize an epithermal neutron beam for studies of parity violation in compound-nuclear resonances. Nearly 0.9 proton polarization was obtained in an electron-beam irradiated ammonia target. This was used to produce a neutron beam polarization of 0.7 at epithermal energies. The combination of the polarized proton target and the LANSCE spallation neutron source produces the most intense pulsed polarized epithermal neutron beam in the world. The neutron-beam polarizer is described and methods to determine neutron beam polarization are presented. copyright 1995 American Institute of Physics

  1. Application of semiconductor MOSFET and pin diode dosimeters to epithermal neutron beam dose distribution measurements in phantoms

    International Nuclear Information System (INIS)

    Carolan, M.G.; Wallace, S.A.; Allen, B.J.; Rosenfeld, A.B.; Mathur, J.N.

    1996-01-01

    For any clinical application of Boron Neutron Capture Therapy (BNCT) fast and accurate dose calculations will be required for treatment planning. Such calculations are also necessary for the planning and interpretation of results from pre-clinical and clinical trials where the speed of calculation is not so critical. A dose calculation system based on the MCNP Monte Carlo Neutron transport code has been developed by Wallace. This system takes image data from CT scans and constructs a voxel based geometrical model for input into MCNP. To validate the calculations, a number of phantoms were constructed and exposed in the HB11 epithermal neutron beam at the HFR of the CEC Joint Research Centre in Petten. The doses recorded by arrays of PIN diode neutron dosimeters and MOSFET gamma dosimeters in these phantoms were compared with the calculated results from the MCNP dose planning system. Initial results have been reported elsewhere. Poster 197. (author)

  2. Neutron activation analysis methodology of marine sediments of the Cuban shelf

    International Nuclear Information System (INIS)

    Garcia, G.

    1988-01-01

    It is described the methodology followed for the neutron activation analysis of marine sediments of the Cuban shelf. A total of 35 elements were determined by means of the employment of thermal and epithermal fluxes of a nuclear reactor as well as from the flux of a generator of 14 MeV neutrons. It is signaled the particularities of detection and measurement of some elements and their interferences, with and special mention of the correction over 153 Sm, 113m In(Sn), 65 Zn, 160 Th, 169 Yb, 75 Sc and 177 Lu. It is concluded that 82% of elements may be determined with epithermal neutrons and 41%, with thermal neutrons. Only Si is determined with 14 MeV neutrons. Moreover, it is recommended the optimal periods of decaying (''cooling'') by groups of elements. The determined elements were: Ag, As, Au, Ba, Br, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Mo, Na, Nd, Ni, Rb, Sb, Sc, Se, Si, Sm, Sn, Sr, Ta, Tb, Th, U, W, Yb, Zn and Zr. The accuracy varied between 1% and 5% to 19 elements, between 6% and 10% to 5 elements, between 11% and 30% to 6 elements and it was greater than 30% to 5 elements

  3. Neutron activation analysis of geochemical samples

    International Nuclear Information System (INIS)

    Rosenberg, R.; Zilliacus, R.; Kaistila, M.

    1983-06-01

    The present paper will describe the work done at the Technical Research Centre of Finland in developing methods for the large-scale activation analysis of samples for the geochemical prospecting of metals. The geochemical prospecting for uranium started in Finland in 1974 and consequently a manually operated device for the delayed neutron activation analysis of uranium was taken into use. During 1974 9000 samples were analyzed. The small capacity of the analyzer made it necessary to develop a completely automated analyzer which was taken into use in August 1975. Since then 20000-30000 samples have been analyzed annually the annual capacity being about 60000 samples when running seven hours per day. Multielemental instrumental neutron activation analysis is used for the analysis of more than 40 elements. Using instrumental epithermal neutron activation analysis 25-27 elements can be analyzed using one irradiation and 20 min measurement. During 1982 12000 samples were analyzed for mining companies and Geological Survey of Finland. The capacity is 600 samples per week. Besides these two analytical methods the analysis of lanthanoids is an important part of the work. 11 lanthanoids have been analyzed using instrumental neutron activation analysis. Radiochemical separation methods have been developed for several elements to improve the sensitivity of the analysis

  4. Characterization of the TRIGA Mark III reactor for k0-neutron activation analysis

    International Nuclear Information System (INIS)

    Diaz R, O.; Herrera P, E.; Lopez R, M.C.

    1997-01-01

    The non-ideality of the epithermal neutron flux distribution in a a reactor site parameter (α), the thermal-to-epithermal neutron ratio (f), the irradiation channel neutron temperature (T n ) and the k 0 -factors for more than 20 isotopes were determined in the 3 typical irradiation positions of the TRIGA Mark III reactor of the National Nuclear Research Institute, Salazar, Mexico, using different experimental methods with conventional and non-conventional monitors. This characterization is used in the k 0 -method of NAA, recently introduced at the Institute. (author). 21 refs., 3 figs., 5 tabs

  5. Measurement of the epithermal neutron flux of the Argonauta reactor by the Sandwich method

    International Nuclear Information System (INIS)

    Nascimento, H.M.

    1973-01-01

    A common method of obtaining information about the neutron spectrum in the energy range of 1 eV to a few keV is by using resonance sandwich detectors. A sandwich detector is usually made up of three foils placed one on top of the other, each having the same thickness and being made of the same material which has a pronounced absorption resonance. To make an adequate evaluation, the sandwich method was compared with one using an isolated detector. The results obtained from approximate theoretical calculations were checked experimentally, using In, Au and Mn foils, in an isotropic 1/E flux in the Argonaut Reactor at I.E.N. As practical application of this method, the deviation from a 1/E spectrum of the epithermal neutron flux in the core and external graphite reflector of the Argonaut Reactor has been measured with the sandwich foils previously calibrated in a 1/E spectrum. (author)

  6. Effective dose evaluation for BNCT treatment in the epithermal neutron beam at THOR

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J.N. [Department of Engineering and System Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China)] [Division of Health Physics, Institute of Nuclear Energy Research, No. 1000, Wenhua Rd., Jiaan Village, Longtan Township, Taoyuan County 32546, Taiwan (China); Huang, C.K. [Institute of Nuclear Engineering and Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China); Tsai, W.C. [Department of Engineering and System Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China); Liu, Y.H. [Nuclear Science and Technol. Develop. Center, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China); Jiang, S.H., E-mail: shjiang@mx.nthu.edu.tw [Department of Engineering and System Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China)] [Institute of Nuclear Engineering and Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China)

    2011-12-15

    This paper aims to evaluate the effective dose as well as equivalent doses of several organs of an adult hermaphrodite mathematical phantom according to the definition of ICRP Publication 60 for BNCT treatments of brain tumors in the epithermal neutron beam at THOR. The MCNP5 Monte Carlo code was used for the calculation of the average absorbed dose of each organ. The effective doses for a typical brain tumor treatment with a tumor treatment dose of 20 Gy-eq were evaluated to be 0.59 and 0.35 Sv for the LLAT and TOP irradiation geometries, respectively. In addition to the stochastic effect, it was found that it is also likely to produce deterministic effects, such as cataracts and depression of haematopoiesis.

  7. Neutron--neutron logging

    International Nuclear Information System (INIS)

    Allen, L.S.

    1977-01-01

    A borehole logging tool includes a steady-state source of fast neutrons, two epithermal neutron detectors, and two thermal neutron detectors. A count rate meter is connected to each neutron detector. A first ratio detector provides an indication of the porosity of the formation surrounding the borehole by determining the ratio of the outputs of the two count rate meters connected to the two epithermal neutron detectors. A second ratio detector provides an indication of both porosity and macroscopic absorption cross section of the formation surrounding the borehole by determining the ratio of the outputs of the two count rate meters connected to the two thermal neutron detectors. By comparing the signals of the two ratio detectors, oil bearing zones and salt water bearing zones within the formation being logged can be distinguished and the amount of oil saturation can be determined. 6 claims, 2 figures

  8. A PC-program for the calculation of neutron flux and element contents using the ki-method of neutron activation analysis

    International Nuclear Information System (INIS)

    Boulyga, E.G.; Boulyga, S.F.

    2000-01-01

    A computer program is described, which calculates the induced activities of isotopes after irradiation in a known neutron field, thermal and epithermal neutron fluxes from the measured induced activities and from nuclear data of 2-4 monitor nuclides as well as the element concentrations in samples irradiated together with the monitors. The program was developed for operation in Windows 3.1 (or higher). The application of the program for neutron activation analysis allows to simplify the experimental procedure and to reduce the time. The program was tested by measuring different types of standard reference materials at the FRJ-2 (Research Centre, Juelich, Germany) and Triga (University Mainz, Germany) reactors. Comparison of neutron flux parameters calculated by this program with those calculated by a VAX program developed at the Research Centre, Juelich was done. The results of testing seem to be satisfactory. (author)

  9. Activation analysis by filtered neutrons. Preliminary investigation

    International Nuclear Information System (INIS)

    Skarnemark, G.; Rodinson, T.; Skaalberg, M.; Tokay, R.K.

    1986-01-01

    In order to investigate if measuring sensibility and precision by epithermal neutron activation analysis may be improved, different types of geological and biologic test samples were radiated. The test samples were enclosed in an extra filter of tungsten or sodium in order to reduce the flux of those neutrons that otherwise would induce interfering activity in the sample. The geological test samples consist of granites containing lanthanides which had been crushed in tung- sten carbide grinder. Normally such test samples show a interferins 1 87W-activity. By use of a tungsten filter the activity was reduced by up to 60%, which resulted in a considerable improvement of sensibility and precision of the measurement. The biologic test samples consisted of evaporated urine from patients treated with the cell poison cis-platinol. A reliable method to measure the platinum content has not existed so far. This method, however, enables platinum contents as low as about 0.1 ppm to be determined which is quite adequate. To sum up this preliminary study has demonstrated that activation analysis using filtered neutrons, correctly applied, is a satisfactory method of reducing interferences without complicated and time-consuming chemical separation procedures. (O.S.)

  10. Utilization and facility of neutron activation analysis in HANARO research reactor

    International Nuclear Information System (INIS)

    Chung, Y.S.; Chung, Y.J.; Moon, J.H.

    1998-01-01

    The facilities of neutron activation analysis within a multi-purpose research reactor (HANARO) are described and the main applications of Neutron activation analysis (NAA) in Korea are reviewed. The sample irradiation tube, automatic and manual pneumatic transfer system, are installed at three irradiation holes. One irradiation hole is lined with a cadmium tube for epithermal-nal NAA. The performance of the NAA facility was examined to identify the characteristics of tube transfer system, irradiation sites and polyethylene irradiation capsule. The available thermal neutron flux with each irradiation site are in the range of 3.9x10 13 -1.6x10 14 n/cm 2 ·s and cadmium ratios are 15-250. Neutron activation analysis has been applied in the trace component analysis of nuclear, geological, biological, environmental and high purity materials and various polymers for research and development. Analytical services and the latest analytical results are summarized. (author)

  11. Determination of silicon in biological and botanical reference materials by epithermal INAA and Compton suppression

    International Nuclear Information System (INIS)

    Landsberger, S.; Peshev, S.; Becker, D.A.

    1994-01-01

    Silicon determination in sixteen botanical and biological standard reference materials is described using the 29 Si(n, p) 29 Al reaction through instrumental epithermal neutron activation analysis and Compton suppression gamma-ray spectroscopy. By simultaneous utilization of both cadmium and boron epithermal filters along with anticoincidence gamma-counting, detection limits as low as 12 ppm were obtained for certain matrices, much lower than previously reported values for this type of analysis. The method is applicable to many botanical and biological matrices and is attractive with its interference free, purely instrumental nature, compared with methods using the 28 Si(n, p) 28 Al reaction or chemical separation techniques. ((orig.))

  12. The instrumental neutron-activation analysis of granites from the Bushveld Complex

    International Nuclear Information System (INIS)

    Watterson, J.I.W.

    1978-01-01

    Three methods of instrumental neutron-activation analysis, 14MeV, reactor thermal, and reactor epithermal, are compared for the analysis of granites form the Bushveld Complex. A total of 34 elements can be determined in the granites by these methods. Samples from the Zaaiplaats area were analysed by thermal neutron activation, and 22 elements were determined in all of them. These elements were used to distinguish between the mineralized Bobbejaankop and Lease granites and the Main granite by the use of multivariate statistics. The Bobbejaankop granite appears as a more-differentaited rock carrying greater amounts of the incompatible elements than does the Main granite [af

  13. Accuracy estimation for intermediate and low energy neutron transport calculation with Monte Carlo code MCNP

    International Nuclear Information System (INIS)

    Kotegawa, Hiroshi; Sasamoto, Nobuo; Tanaka, Shun-ichi

    1987-02-01

    Both ''measured radioactive inventory due to neutron activation in the shield concrete of JPDR'' and ''measured intermediate and low energy neutron spectra penetrating through a graphite sphere'' are analyzed using a continuous energy model Monte Carlo code MCNP so as to estimate calculational accuracy of the code for neutron transport in thermal and epithermal energy regions. Analyses reveal that MCNP calculates thermal neutron spectra fairly accurately, while it apparently over-estimates epithermal neutron spectra (of approximate 1/E distribution) as compared with the measurements. (author)

  14. Elemental Study in Soybean and Products by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Vorapot, Permnamtip; Arporn Busamongkol; Sirinart, Laoharojanaphand

    2009-07-01

    Full text: Elements were analyzed in soybean and products by Instrumental Neutron Activation Analysis (INAA), Pseudo-Cyclic Instrumental Neutron Activation Analysis (PCINAA) and Epithermal Instrumental Neutron Activation Analysis (EINAA). Elements detected in sample were include Al, Br, Ca, Cl, Cu, Fe, I, K, Mg, Mn Na, Se and Zn. The result showed that the nutritional contents changed after food processing. From experiments (n = 2), it was found that after food processing, the concentration of Cl and Na in soy bean curd increased from 0.0045 and 0.0011% to found 0.91 and 0.39 %, respectively. Other elements did not differ from soybean. Limits of detection for Al, Br, Ca, Cl, Cu, Fe, I, K, Mg, Mn Na, Se and Zn were 0.05, 0.2, 50, 6, 10, 15, 0.05, 30, 40, 5, 5, 0.05 and 1 mg.kg - 1, respectively

  15. Examination of Greek neolithic ceramic shards by epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Ochsenkuehn, K.M.; Zouridakis, N.; Inst. of Physical Chemistry, Athens; Ochsenkuehn-Petropulu, M.

    1999-01-01

    At the reactor of the NCSR 'Demokritos' epithermal irradiation was used in connection with a loss-free counting technique to investigate rare Neolithic ceramic shards, about 4000 years old, from the Alepotrypa Cave of Diros, Greece. The application of an irradiation time of 30 minutes, the measurements of the samples after less then 24 hours and a counting time of 20 minutes in connection with a loss-free counting unit allowed the determination of 12 elements per sample. The comparison of these rare fine ceramic shards with those of primitive shape showed that both were produced from the same raw materials. Small differences could be explained by a raw material pretreatment. The Neolithic potters were obviously aware of separation techniques in order to obtain fine clay fractions to produce those rare ceramics. (author)

  16. TRANSHEX, 2-D Thermal Neutron Flux Distribution from Epithermal Flux in Hexagonal Geometry

    International Nuclear Information System (INIS)

    Patrakka, E.

    1994-01-01

    1 - Description of program or function: TRANSHEX is a multigroup integral transport program that determines the thermal scalar flux distribution arising from a known epithermal flux in two- dimensional hexagonal geometry. 2 - Method of solution: The program solves the isotropic collision probability equations for a region-averaged scalar flux by an iterative method. Either a successive over-relaxation or an inner-outer iteration technique is applied. Flat flux collision probabilities between trigonal space regions with white boundary condition are utilized. The effect of epithermal flux is taken into consideration as a slowing-down source that is calculated for a given spatial distribution and 1/E energy dependence of the epithermal flux

  17. Utilization and facility of neutron activation analysis in HANARO research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y S; Chung, Y J; Moon, J H [Korea Atomic Energy Research Institute, P.O.Box 105 Yusong, 305-600, Taejon (Korea, Republic of)

    1998-07-01

    The facilities of neutron activation analysis within a multi-purpose research reactor (HANARO) are described and the main applications of Neutron activation analysis (NAA) in Korea are reviewed. The sample irradiation tube, automatic and manual pneumatic transfer system, are installed at three irradiation holes. One irradiation hole is lined with a cadmium tube for epithermal-nal NAA. The performance of the NAA facility was examined to identify the characteristics of tube transfer system, irradiation sites and polyethylene irradiation capsule. The available thermal neutron flux with each irradiation site are in the range of 3.9x10{sup 13}-1.6x10{sup 14} n/cm{sup 2}{center_dot}s and cadmium ratios are 15-250. Neutron activation analysis has been applied in the trace component analysis of nuclear, geological, biological, environmental and high purity materials and various polymers for research and development. Analytical services and the latest analytical results are summarized. (author)

  18. Personal neutron dosimeter using solid-state track detector

    International Nuclear Information System (INIS)

    Mettripan, S.

    1980-01-01

    A cellulose nitrate film coated on both sides with lithium tetraborate was used as a neutron dosimeter for surveillance of personnel exposed to thermal and epithermal neutron. It was found that the optimum etching conditions used were 10% solution of sodium hydroxide, 60 degrees C and 20 minutes etching time and the alpha track densities from the (n,α) reaction on the films were proportional to thermal and epithermal neutron fluxes. The response of the film was found to be 1.068 x 10 -3 tracks per thermal neutron and 3.438 x 10 -4 tracks per epithermal neutron

  19. Characterization of the Ljubljana TRIGA thermal column neutron radiographic facility

    International Nuclear Information System (INIS)

    Nemec, T.; Rant, J.; Kristof, E.; Glumac, B.

    1995-01-01

    An extensive characterization of the neutron beam of the existing neutron radiographic facility in the thermal column of the Ljubljana Triga Mark II research reactor is in progress. Neutron beam characteristics are needed to determine the effect of various neutron and gamma radiation on the neutron radiographic image. Commercially available medical scintillator converter screens based on Gd dioxy sulphite as well as Gd metal neutron converters are used to record neutron radiographic image. Thermal, epithermal and fast neutron fluxes were measured using Au and In activation detectors and cadmium ratio is determined. Neutron beam flux profiles are measured by film densitometry and by Au activation detector wires. By exposing films shielded by boral or lead plates individual contributions of thermal, epithermal neutrons and gamma radiation are estimated by densitometric measurements. By recording images of neutron image quality indicators BPI (Beam Purity Indicator) and SI (Sensitivity Indicator) produced by Riso, standard neutron radiography image characteristic are established. In gamma dosimetric measurements thermoluminescent detectors (CaF 2 Mn) are used. (author)

  20. A neutron beam polarizer for study of parity violation in neutron-nucleus interactions

    International Nuclear Information System (INIS)

    Penttilae, S.I.; Bowman, J.D.; Frankle, C.M.; Seestrom, S.J.; Yen, Yi-Fen; Delheij, P.P.J.; Haase, D.G.; Postma, H.

    1994-01-01

    A dynamically-polarized proton target operating at 5 Tesla and 1 K has been built to, neutron beam for studies of parity violation in compound-nuclear resonances. Nearly 0.9 proton polarization was obtained in an electron-beam irradiated ammonia target. This was used to produce a neutron beam polarization of 0.7 at epithermal energies. The combination of the polarized proton target and the LANSCE spallation neutron source produces the most intense pulsed polarized epithermal neutron beam in the world. The neutron-beam polarizer is described and methods to determine neutron beam polarization are presented

  1. The effect of cadmium shielding on the spatial neutron flux distribution inside one of the outer irradiation sites

    International Nuclear Information System (INIS)

    Shaaban, I.

    2009-06-01

    A permanent epithermal neutron irradiation facility was designed in the Syrian Miniature Neutron Source Reactor (MNSR) by using the cadmium (cylindrical vial 1.0 mm in thickness, 38.50 mm in diameter and 180 mm in length) as thermal neutron shielding material, for a permanent epithermal neutron activation analysis (ENAA). This site was designed by shielding the internal surface of the aluminum tube of the first outer irradiation site in the MNSR reactor. I was used the activation detectors 0.1143% Au-Al alloy foils with 0.1 mm thickness and 2.0 mm diameter for measurement the thermal neutron flux, epithermal and R c d=A b are/A c over ratio in the outer irradiation site. Distribution of the thermal neutron flux in the outer irradiation capsule has been found numerically using MCNP-4C code with and without cadmium shield, and experimentally by irradiating five copper wires using the outer irradiation capsule. Good agreements were obtained between the calculated and the measured results. (author)

  2. A large animal model for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Gavin, P.R.; Kraft, S.L.; DeHaan, C.E.; Moore, M.P.; Griebenow, M.L.

    1992-01-01

    An epithermal neutron beam is needed to treat relatively deep seated tumors. The scattering characteristics of neutrons in this energy range dictate that in vivo experiments be conducted in a large animal to prevent unacceptable total body irradiation. The canine species has proven an excellent model to evaluate the various problems of boron neutron capture utilizing an epithermal neutron beam. This paper discusses three major components of the authors study: (1) the pharmacokinetics of borocaptate sodium (NA 2 B 12 H 11 SH or BSH) in dogs with spontaneously occurring brain tumors, (2) the radiation tolerance of normal tissues in the dog using an epithermal beam alone and in combination with borocaptate sodium, and (3) initial treatment of dogs with spontaneously occurring brain tumors utilizing borocaptate sodium and an epithermal neutron beam

  3. Activation method for measuring the reaction rates and studying the neutron spectra parameters, based on using the unified composition detectors

    International Nuclear Information System (INIS)

    Demidov, A.M.; Dikarev, V.S.; Efimov, B.V.; Ionov, V.S.; Marin, S.V.

    2005-01-01

    The method proposed for estimation of parameters thermal and epithermal parts of energy distribution of neutrons is described. The method based on application of activation measuring with use of unified composition detectors (UCD) and samples of fuel. The method is applicable for definition of neutron spectrum parameters and velocities of division in fuel of nuclear installations. Theoretical bases and the description of a method, expedients of manufacturing and calibration for the detectors, the experimental data, carried out in RRC KI are given and processing of experimental data, and also. The parametric model of a spectrum constructed on the basis of Westcott's formalism is described. The parameter of stiffness is entered and its role for temperature of neutron gas, spectral coefficients of isotopes of detectors, the transition area thermal and epithermal parts of neutron spectra is observationally appreciated. It is offered to confirm the found results by calculations with use of MCU Monte Carlo code [ru

  4. Simultaneous thermal neutron decay time and porosity logging system

    International Nuclear Information System (INIS)

    Smith, H.D. Jr.; Smith, M.P.; Schultz, W.E.

    1979-01-01

    A simultaneous pulsed neutron porosity and thermal neutron capture cross section logging system is provided for radiological well logging of subsurface earth formations. A logging tool provided with a 14 MeV pulsed neutron source, an epithermal neutron detector, and a combination gamma ray and fast neutron detector is moved through a borehole. Repetitive bursts of neutrons irradiate the earth formations; and, during the bursts, the fast neutron and epithermal neutron populations are sampled. During the interval between bursts the thermal neutron capture gamma ray population is sampled in two or more time intervals. The fast and epithermal neutron population measurements are combined to provide a measurement of formation porosity phi. The capture gamma ray measurements are combined to provide a simultaneous determination of the thermal neutron capture cross section Σ

  5. Study of spectral response of a neutron filter. Design of a method to adjust spectra

    International Nuclear Information System (INIS)

    Colomb-Dolci, F.

    1999-02-01

    The first part of this thesis describes an experimental method which intends to determine a neutron spectrum in the epithermal range [1 eV -10 keV]. Based on measurements of reaction rates provided by activation foils, it gives flux level in each energy range corresponding to each probe. This method can be used in any reactor location or in a neutron beam. It can determine scepter on eight energy groups, five groups in the epithermal range. The second part of this thesis presents a study of an epithermal neutron beam design, in the frame of Neutron Capture Therapy. A beam tube was specially built to test filters made up of different materials. Its geometry was designed to favour epithermal neutron crossing and to cut thermal and fast neutrons. A code scheme was validated to simulate the device response with a Monte Carlo code. Measurements were made at ISIS reactor and experimental spectra were compared to calculated ones. This validated code scheme was used to simulate different materials usable as shields in the tube. A study of these shields is presented at the end of this thesis. (author)

  6. Rapid determination of halogenes in milk by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Alfassi, Z.B.; Lavi, N.

    1985-01-01

    The absolute concetrations of iodine, bromine and chlorine in milk were determined by epithermal neutron activation followed by high resolution gamma-ray spectrometry. Two kinds of milk commonly consumed in Israel were investigated. The concentration of iodine, bromine and chlorine were found to be 0.18-0.30 μg/ml, 2.02-2.85 μg/ml and 0.65 mg/ml, respectively. The method is fast, selective, accurate and highly sensitive. (author)

  7. Neutron activation analysis at the 'Instituto de Pesquisas Energeticas e Nucleares' (SP, Brazil)

    International Nuclear Information System (INIS)

    Vasconcellos, M.B.A.

    1984-01-01

    A review of the work carried out at IPEN using neutron activation analysis is made. The main characteristics of the technique and general experimental procedures applied for different samples and elements are reported. Geological samples were analysed by using activation with thermal, epithermal and delayed neutrons (for U and Th, specifically). Metallic samples were analysed for several elements in trace amounts (Ta in Nb, Hg in steel, Sn, Sb, As, Cu, Cr and Ag in a tin-lead alloy). Biological materials, such as tomatoes, animal and human viscera, food, hair, nails were also analysed for several components (Hg, Na, K, As, Au and others). (Author) [pt

  8. Modern Trends in Neutron Activation Analysis. Applications to some African Environmental Samples

    International Nuclear Information System (INIS)

    Hassan, A.M.

    2009-01-01

    This review covers the results of several published articles which deal with the modern trends in neutron activation analysis techniques using some of African research reactors for some environmental samples. The samples used have been collected from different areas in Egypt, South Africa, Ghana, Morocco, Nigeria, and Algeria. The neutron irradiation facilities and the advanced detection systems in each country are outlined. The prompt and delayed gamma-rays emitted due to neutron capture have been applied for investigation of the elemental constituents of such samples. Covered applications include exploration, mining, industrial environment, pollution of air, foodstuffs, soils and irrigation water samples. Some of the developed software programmes as well as the modern methods of data analysis are presented. The thermal and epithermal neutron activation analysis techniques have been applied for estimation of major, minor and trace elements in each material. Some of these data are presented with several comments.

  9. Trace elements in 11 fruits widely-consumed in the USA as determined by neutron activation analysis

    International Nuclear Information System (INIS)

    Michenaud-Rague, A.; Robinson, S.; Landsberger, S.

    2012-01-01

    While there is a lot of information on the elemental content of food for nutritional and pollution studies, the analysis of fruits has received little attention. We have investigated 11 commonly eaten fruits for their trace and minor element constituents by neutron activations including thermal and epithermal neutron activation analysis. Our results revealed that both blueberries and strawberries had the most of top two highest elemental concentrations followed by raspberries, oranges and mango. Bananas, grapes, plums, apples, pears, and cherries had the fewest or none of the most elevated elemental concentrations. (author)

  10. Activation method for measurement of neutron spectrum parameters

    International Nuclear Information System (INIS)

    Efimov, B.V.; Demidov, A.M.; Ionov, V.S.; Konjaev, S.I.; Marin, S.V.; Bryzgalov, V.I.

    2007-01-01

    Experimental researches of spectrum parameters of neutrons at nuclear installations RRC KI are submitted. The installations have different designs of the cores, reflector, parameters and types of fuel elements. Measurements were carried out with use of the technique developed in RRC KI for irradiation resonance detectors UKD. The arrangement of detectors in the cores ensured possibility of measurement of neutron spectra with distinguished values of parameters. The spectrum parameters which are introduced by parametrical representation of a neutrons spectrum in the form corresponding to formalism Westcott. On experimental data were determinate absolute values of density neutron flux (DNF) in thermal and epithermal area of a spectrum (F t , f epi ), empirical dependence of temperature of neutron gas (Tn) on parameter of a rigidity of a spectrum (z), density neutron flux in transitional energy area of the spectrum. Dependences of spectral indexes of nuclides (UDy/UX), included in UKD, from a rigidity z and-or temperatures of neutron gas Tn are obtained.B Tools of mathematical processing of results are used for activation data and estimation of parameters of a spectrum (F t , f epi , z, Tn, UDy/UX). In the paper are presented some results of researches of neutron spectrum parameters of the nuclear installations (Authors)

  11. Activation analysis of high pure quartz used as packing materials

    International Nuclear Information System (INIS)

    Luknitskij, V.A.; Morozov, B.A.

    1979-01-01

    A γ-spectrometric technique of neutron activation determination of microelements in quartz tubes used as a packing material for irradiation in reactors is reported. The analysis of 29 micro-admixtures in quartz tubes of USSR brands ''spectrtosil'' and ''KV'' was carried out. The γ-spectra of ''KV'' quartz irradiated by thermal and epithermal neutrons are presented. The activation by epithermal neutrons provides an activity gain for the nuclei whose resonance integral is high enough as compared to the activation cross-section with regard to thermal neutrons. The activation by epithermal neutrons permits additional determination of W, Cd, V, Th, Mn and Ni and provides for a substantial decrease in the activity of 24 Na, 42 K, 140 La, 46 Sc, 141 Ce, 51 Cr, and 59 Fe, which hinder the determination of the above-mentioned elements. The microelement composition of Soviet-made quartz varieties is compared to that of foreign-made quartz brands

  12. Characterization of bauxite residue (red mud) for 235U, 238U, 232Th and 40K using neutron activation analysis and the radiation dose levels as modeled by MCNP.

    Science.gov (United States)

    Landsberger, S; Sharp, A; Wang, S; Pontikes, Y; Tkaczyk, A H

    2017-07-01

    This study employs thermal and epithermal neutron activation analysis (NAA) to quantitatively and specifically determine absorption dose rates to various body parts from uranium, thorium and potassium. Specifically, a case study of bauxite residue (red mud) from an industrial facility was used to demonstrate the feasibility of the NAA approach for radiological safety assessment, using small sample sizes to ascertain the activities of 235 U, 238 U, 232 Th and 40 K. This proof-of-concept was shown to produce reliable results and a similar approach could be used for quantitative assessment of other samples with possible radiological significance. 238 U and 232 Th were determined by epithermal and thermal neutron activation analysis, respectively. 235 U was determined based on the known isotopic ratio of 238 U/ 235 U. 40 K was also determined using epithermal neutron activation analysis to measure total potassium content and then subtracting its isotopic contribution. Furthermore, the work demonstrates the application of Monte Carlo Neutral-Particle (MCNP) simulations to estimate the radiation dose from large quantities of red mud, to assure the safety of humans and the surrounding environment. Phantoms were employed to observe the dose distribution throughout the human body demonstrating radiation effects on each individual organ. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Generating energy dependent neutron flux maps for effective ...

    African Journals Online (AJOL)

    For activation analysis and irradiation scheme of miniature neutron source reactor, designers or engineers usually require information on thermal neutron flux levels and other energy group flux levels (such as fast, resonance and epithermal). A methodology for readily generating such flux maps and flux profiles for any ...

  14. Neutron activation analysis of gold and prospectiveness of its application

    International Nuclear Information System (INIS)

    Tong Chunhan.

    1988-01-01

    NAA of gold is a method of high sensitivity and high percision, especially when epithermal neutron activation is applied. NAA is particularly emphasized in the process of gold reference standards preparation. In addition to the pure instrumental NAA, the NAA with pre-enrichment before sctivation is developed. This technque has been successfully used in assessment of micro and fine grained Au-Ag-phlymetal ores in Guixian, Guangxi. Through this example, prospectiveness of NAA application in Au-Ag-prospecting, fast assessment and trace element geochemistry investigation is seen

  15. Measurements of neutron flux in the RA reactor

    International Nuclear Information System (INIS)

    Raisic, N.

    1961-12-01

    This report includes the following separate parts: Thermal neutron flux in the experimental channels od RA reactor; Epithermal neutron flux in the experimental channels od RA reactor; Fast neutron flux in the experimental channels od RA reactor; Thermal neutron flux in the thermal column and biological experimental channel; Neutronic measurements in the RA reactor cell; Temperature reactivity coefficient of the RA reactor; design of the device for measuring the activity of wire [sr

  16. Boron Neutron Capture Therapy activity of diffused tumors at TRIGA Mark II in Pavia

    Energy Technology Data Exchange (ETDEWEB)

    Bortolussi, S.; Stella, S.; De Bari, A.; Altieri, S. [Department of Nuclear and Theoretical Physics, University of Pavia, Pavia (Italy)]|[National Institute of Nuclear Physics (INFN), Pavia (Italy); Bruschi, P.; Bakeine, J.G. [Department of Nuclear and Theoretical Physics, University of Pavia, Pavia (Italy); Clerici, A.; Ferrari, C.; Zonta, C.; Zonta, A. [Department of Surgery, University of Pavia, Pavia (Italy); Nano, R. [Department of Animal Biology, University of Pavia, Pavia (Italy)

    2008-10-29

    The Boron neutron Capture Therapy research in Pavia has a long tradition: it begun more than 20 years ago at the TRIGA Mark II reactor of the University. A technique for the treatment of the hepatic metastases was developed, consisting in explanting the liver treated with {sup 10}B, irradiating it in the thermal column of the reactor, and re-implanting the organ in the patient. In the last years, the possibility of applying BNCT to the lung tumours using epithermal collimated neutron beams and without explanting the organ, is being explored. The principal obtained results of the BNCT research will be presented, with particular emphasis on the following aspects: a) the project of a new thermal column configuration to make the thermal neutron flux more uniform inside the explanted liver, b) the Monte Carlo study by means of the MCNP code of the thermal neutron flux distribution inside a patient's thorax irradiated with epithermal neutrons, and c) the measurement of the boron concentration in tissues by (n,{alpha}) spectroscopy and neutron autoradiography. (authors)

  17. Boron Neutron Capture Therapy activity of diffused tumors at TRIGA Mark II in Pavia

    International Nuclear Information System (INIS)

    Bortolussi, S.; Stella, S.; De Bari, A.; Altieri, S.; Bruschi, P.; Bakeine, J.G.; Clerici, A.; Ferrari, C.; Zonta, C.; Zonta, A.; Nano, R.

    2008-01-01

    The Boron neutron Capture Therapy research in Pavia has a long tradition: it begun more than 20 years ago at the TRIGA Mark II reactor of the University. A technique for the treatment of the hepatic metastases was developed, consisting in explanting the liver treated with 10 B, irradiating it in the thermal column of the reactor, and re-implanting the organ in the patient. In the last years, the possibility of applying BNCT to the lung tumours using epithermal collimated neutron beams and without explanting the organ, is being explored. The principal obtained results of the BNCT research will be presented, with particular emphasis on the following aspects: a) the project of a new thermal column configuration to make the thermal neutron flux more uniform inside the explanted liver, b) the Monte Carlo study by means of the MCNP code of the thermal neutron flux distribution inside a patient's thorax irradiated with epithermal neutrons, and c) the measurement of the boron concentration in tissues by (n,α) spectroscopy and neutron autoradiography. (authors)

  18. Neutron reflector design with Californium 252 neutron for Boron neutron chapter therapy facility using MCNP5 simulation method

    International Nuclear Information System (INIS)

    Muhammad Fakhrurreza; Kusminanto; Y Sardjono

    2014-01-01

    In this research has made a reflector design to provide beams of Neutron for BNCT with Californium-252 radioactive source. This collimator is useful to obtain optimum epithermal neutron flux with the smallest impurity radiation (thermal neutron, fast neutron, and gamma). The design process is done using Monte Carlo N-Particle simulation version 5 (MCNP5) code to calculate the neutron flux tally form. The chosen reflector design is the reflectors which use material such as BeO ceramic with 13 cm thick. Moderator use sulfur material with the slope angle of the cone is 30°. From the calculation result, it is obtained that Reflector with 1 gram Californium-252 source can produce a neutron output thermal which has thermal neutron specification 2.23189 x 10 9 n/s.cm 2 , epithermal neutron 3.51548 x 10 9 n/s.cm 2 , and fast neutron 4.82241 x 10 9 n/s.cm 2 From the result, it needs additional collimator because the BNCT requirement. (author)

  19. Study of spectral response of a neutron filter. Design of a method to adjust spectra; Etude des moyens de conditionnement de la reponse spectrale d'un filtre a neutrons. Mise au point d'une methode d'ajustement rapide de spectre

    Energy Technology Data Exchange (ETDEWEB)

    Colomb-Dolci, F. [Universite Louis Pasteur, 67 - Strasbourg (France)

    1999-02-01

    The first part of this thesis describes an experimental method which intends to determine a neutron spectrum in the epithermal range [1 eV -10 keV]. Based on measurements of reaction rates provided by activation foils, it gives flux level in each energy range corresponding to each probe. This method can be used in any reactor location or in a neutron beam. It can determine scepter on eight energy groups, five groups in the epithermal range. The second part of this thesis presents a study of an epithermal neutron beam design, in the frame of Neutron Capture Therapy. A beam tube was specially built to test filters made up of different materials. Its geometry was designed to favour epithermal neutron crossing and to cut thermal and fast neutrons. A code scheme was validated to simulate the device response with a Monte Carlo code. Measurements were made at ISIS reactor and experimental spectra were compared to calculated ones. This validated code scheme was used to simulate different materials usable as shields in the tube. A study of these shields is presented at the end of this thesis. (author)

  20. The secondary neutron sources for generation of particular neutron fluxes

    International Nuclear Information System (INIS)

    Tracz, G.

    2007-07-01

    The foregoing paper presents the doctor's thesis entitled '' The secondary neutron sources for generation of particular neutron fluxes ''. Two secondary neutron sources have been designed, which exploit already existing primary sources emitting neutrons of energies different from the desired ones. The first source is devoted to boron-neutron capture therapy (BNCT). The research reactor MARIA at the Institute of Atomic Energy in Swierk (Poland) is the primary source of the reactor thermal neutrons, while the secondary source should supply epithermal neutrons. The other secondary source is the pulsed source of thermal neutrons that uses fast 14 MeV neutrons from a pulsed generator at the Institute of Nuclear Physics PAN in Krakow (Poland). The physical problems to be solved in the two mentioned cases are different. Namely, in order to devise the BNCT source the initial energy of particles ought to be increased, whilst in the other case the fast neutrons have to be moderated. Slowing down of neutrons is relatively easy since these particles lose energy when they scatter in media; the most effective moderators are the materials which contain light elements (mostly hydrogen). In order to increase the energy of neutrons from thermal to epithermal (the BNCT case) the so-called neutron converter should be exploited. It contains a fissile material, 235 U. The thermal neutrons from the reactor cause fission of uranium and fast neutrons are emitted from the converter. Then fissile neutrons of energy of a few MeV are slowed down to the required epithermal energy range. The design of both secondary sources have been conducted by means of Monte Carlo simulations, which have been carried out using the MCNP code. In the case of the secondary pulsed thermal neutron source, some of the calculated results have been verified experimentally. (author)

  1. {sup 124}Sb–Be photo-neutron source for BNCT: Is it possible?

    Energy Technology Data Exchange (ETDEWEB)

    Golshanian, Mohadeseh [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of); Department of Physics, Shahrood University, Shahrood (Iran, Islamic Republic of); Rajabi, Ali Akbar [Department of Physics, Shahrood University, Shahrood (Iran, Islamic Republic of); Kasesaz, Yaser, E-mail: ykasesaz@aeoi.org.ir [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of)

    2016-11-01

    In this research a computational feasibility study has been done on the use of {sup 124}SbBe photo-neutron source for Boron Neutron Capture Therapy (BNCT) using MCNPX Monte Carlo code. For this purpose, a special beam shaping assembly has been designed to provide an appropriate epithermal neutron beam suitable for BNCT. The final result shows that using 150 kCi of {sup 124}Sb, the epithermal neutron flux at the designed beam exit is 0.23×10{sup 9} (n/cm{sup 2} s). In-phantom dose analysis indicates that treatment time for a brain tumor is about 40 min which is a reasonable time. This high activity {sup 124}Sb could be achieved using three 50 kCi rods of {sup 124}Sb which can be produced in a research reactor. It is clear, that as this activity is several hundred times the activity of a typical cobalt radiotherapy source, issues related to handling, safety and security must be addressed.

  2. Neutron sensitivity of prompt-response self-powered neutron detectors and the interval rule

    International Nuclear Information System (INIS)

    Molina Avila, J.; Carmolopes, M.

    1989-01-01

    This paper is devoted to the calculation of thermal s th and epithermal s epi sensitivities of cobalt prompt-response Self-Powered Neutron Detectors (SPNDs). The thermal sensitivity was obtained for a Maxwellian neutron field, and the effect of scattering on the self-shielding correction was taken into consideration in the second-collision approximation. The dependence of s th on the emitter radius R was studied in a wide region of R (0.025 to 0.2 cm). The differential and global epithermal sensitivities were calculated using a simple expression for the first-collision neutron absorption probability. Finally, a criterion to evaluate the accuracy of the parameters of the model was established in the form of some Interval Rule which is very sensitive to the radial dependence of the flux perturbation correction and other parameters of the model in both the thermal and epithermal regions

  3. Thick-foils activation technique for neutron spectrum unfolding with the MINUIT routine-Comparison with GEANT4 simulations

    Science.gov (United States)

    Vagena, E.; Theodorou, K.; Stoulos, S.

    2018-04-01

    Neutron activation technique has been applied using a proposed set of twelve thick metal foils (Au, As, Cd, In, Ir, Er, Mn, Ni, Se, Sm, W, Zn) for off-site measurements to obtain the neutron spectrum over a wide energy range (from thermal up to a few MeV) in intense neutron-gamma mixed fields such as around medical Linacs. The unfolding procedure takes into account the activation rates measured using thirteen (n , γ) and two (n , p) reactions without imposing a guess solution-spectrum. The MINUIT minimization routine unfolds a neutron spectrum that is dominated by fast neutrons (70%) peaking at 0.3 MeV, while the thermal peak corresponds to the 15% of the total neutron fluence equal to the epithermal-resonances area. The comparison of the unfolded neutron spectrum against the simulated one with the GEANT4 Monte-Carlo code shows a reasonable agreement within the measurement uncertainties. Therefore, the proposed set of activation thick-foils could be a useful tool in order to determine low flux neutrons spectrum in intense mixed field.

  4. Determination of trace gold in rocks and minerals by neutron activation analysis

    International Nuclear Information System (INIS)

    Zhao Yunlong; Zhou Suqing; Liang Yutang

    1988-05-01

    The determination of trace gold in rocks and minerals by neutron activation analysis is described. Two methods are used for pre-separating and concentrating the trace gold in geological samples. one of the methods is that the samples are dissolved in aqua regia solution; activated carbon paper pulp filter is used for pre-separating and concentrating trace gold by dynamic adsorption method; then the activated carbon containing gold was ashed at 650 ∼ 700 deg c. The other method is that the samples are dissolved in aqua regia solution; the polyurethane foam plastic filled with activated carbon is used for pre-separating and concentrating trace gold by dynamic adsorption method; then the foam plastic containing gold was ashed at 650 deg c. The gold in ashes is determinated by neutron activation analysis. The detection limit is 0.004ng/g. The accuracy of the method is examined by gold in reference standard material. The results of this method are in good agreement with the recommended value. For analysis of the trace gold by the methods of instrumental neutron activation analysis and epithermal neutron activation analysis, the interference of 411.8 keV γ-ray from 153 Sm, 152 Eu and fission products of uranium and the correction methods are discussed

  5. A neutron irradiator applied to cancer treatment

    International Nuclear Information System (INIS)

    Campos, Tarcisio P.R.; Andrade, Ana P. de

    2000-01-01

    Cancer and the way of treating it with neutron capture therapy are addressed. This paper discusses also the type of neutron facilities used to treat cancer around the world, as follow: discrete neutron sources, accelerators, and nuclear reactors. The major features of an epithermal neutron irradiation facility applied to BNCT treatment are addressed. The main goal is to give another choice of neutron irradiators to be set in a hospital. The irradiation facility embeds a set of 252 Cf neutron source coupled with a homogeneous mixture of uranium-zirconium hydride alloy containing 8.4 wt % uranium enriched to 20% U 235 . The facility delivers an epithermal neutron beam with low background of fast neutron and gamma rays. The N particle transport code (MCNP-4A) has been used during the simulation in order to achieve the desired configurations and to estimate the multiplication factor, k eff . The present facility loaded with 30 mg of 252 Cf neutron source generates an external beam with an intensity of 10 7 n/cm 2 .s on the spectrum of 4 eV to 40 KeV. The 252 Cf - facility coupled with fissile material was able to amplify the epithermal flux to 10 8 n/cm 2 .s, maintaining the figure-of-merits represented by the ratios of the fast dose and gamma dose in air per epithermal neutron flux closed to those values presented by BMRR, MITR-II and Petten Reactor. The medical irradiation facility loaded with 252 Cf- 235 U can be a choice for BNCT. (author)

  6. Fast-neutron activation analysis of manganese nodules

    International Nuclear Information System (INIS)

    Michaelis, W.; Fanger, H.U.; Mueller, A.; Pepelnik, R.

    1976-01-01

    The present paper describes the development of a new nuclear method that allows rapid determinations of the most relevant metals Ni and Cu without sample treatment, thus being particularly suited for quasi-continuous elemental analyses in mining and processing. The measurement is based on fast-neutron activation using Cockcroft-Walton generators, sealed neutron tubes or, possibly, (α,n)-type natural sources. Fast-neutron activation of manganese nodules is dominated by the (n,p)-reactions on Si, Al, Fe; the (n,α)-reaction on Mn and the (n,2n)-reaction on Cu. By choosing appropriate irradiation and cooling periods gamma-ray activities with comparatively simple spectral distributions are induced. From these spectra the Mn/Fe ratio in the nodules can be determined without the elaborate procedures usually required in absolute methods for eliminating systematic errors from fluctuations in sample and/or irradiation parameters. It is connected with the absolute Ni and Cu contents via well-known geochemical correlations which according to a lot of statistical data apply to quite different deposits and nodule types in the Pacific. Using these correlations the determination of the most important metals reduces to the evaluation of a peak area ratio. Measurements of the neutron flux distribution and the apparent sample density are unnecessary. The simple structure of the spectra allows the application of detectors with modest energy resolution, e.g. scintillation counters which can be manufactured as ruggedized crystal assemblies with great resistance to thermal and mechanical shock. The method is described in detail and possible interference, in particular from thermal and epithermal neutrons, are discussed. (orig.) [de

  7. The monostandard method in thermal neutron activation analysis of geological, biological and environmental materials

    International Nuclear Information System (INIS)

    Alian, A.; Djingova, R.G.; Kroener, B.; Sansoni, B.

    1984-01-01

    A simple method is described for instrumental multielement thermal neutron activation analysis using a monostandard. For geological and air dust samples, iron is used as a comparator, while sodium has advantages for biological materials. To test the capabilities of this method, the values of the effective cross sections of the 23 elements determined were evaluated in a reactor site with an almost pure thermal neutron flux of about 9x10 12 nxcm -2 xs -1 and an epithermal neutron contribution of less than 0.03%. The values obtained were found to agree mostly well with the best literature values of thermal neutron cross sections. The results of an analysis by activation in the same site agree well with the relative method using multielement standards and for several standard reference materials with certified element contents. A comparison of the element contents obtained by the monostandard and relative methods together with corresponding precisions and accuracies is given. (orig.) [de

  8. The epithermal critical experiments; Experiences critiques avec des neutrons epitliermiques; Nadteplovye kriticheskie ehksperimenty; Experimentos criticos con neutrones epitermicos

    Energy Technology Data Exchange (ETDEWEB)

    Morewitz, H A; Carpenter, S O [Atomics International, Canoga Park, CA (United States)

    1962-03-15

    The epithermal critical experiments. The present phase of the advanced-epithermal-thorium-reactor programme consists of integral-reactor-physic s experiments designed to provide neutron-cross-section information in the 10-MeV to 1-keV range. A series of nine, multi-region, slow-fast, pseudospherica l critical assemblies of the honey- comb, split-table type are being studied. So far, three assemblies have' been run. The outer driver-decouple r region drives an interior U{sup 233}-Th fuelled spherical test region whose neutron-flux spectrum is successively degraded by increasing the graphite moderator to fuel ratio. A square-wave oscillator experiment defines the central reactivity worths of forty small samples of different materials to 10{sup -8} {Delta}k for each assembly. Additionally, intercalibrated artificial neutron sources are oscillated to determine the various central neutron importance functions. The spectra are obtained by fission-counter measurements with calibrated foils of different thresholds and by a Li{sup 6}-solid-state- counter sandwich spectrometer. A digital computer routine will be used to compile all measurements into a self-consistent library of spectrum averaged cross-sections. (author) [French] La phase actuelle du programme de reacteur au thorium a neutrons epithermiques comprend des experiences integrales de physique des reacteurs pour obtenir des renseignements sur les sections efficaces neutroniques pour la gamme d'energie comprise entre 1 keV et 10 MeV. Les auteurs etudient une serie de neuf ensembles critiques pseudospheriques, a plusieurs regions, a couplage neutrons lents et neutrons rapides du type a alveoles et a coeur divise. A ce jour, trois de ces ensembles ont ete mis en service. La region exterieure, mettant en service ou hors service, commande une zone d'essai interieure de forme spherique ou le combustible est constitue de {sup 233}U-Th, dont le spectre du flux de neutrons est degrade progressivement par augmentation du

  9. Determination of Neutron Flux Parameter f and α and k0 Factor in Irradiation Facility of RSG GA Siwabessy reactor

    International Nuclear Information System (INIS)

    Amir Hamzah

    2004-01-01

    Determination of neutron flux thermal to epithermal ratio f and parameter α and k 0 factor has been done in irradiation facility of RSG G.A. Siwabessy reactor. Those parameters are needed to determine the concentration of an element in a sample using k 0 NAA method. Parameters f was measured using foil activation method and α parameter was obtained from power function fitting at epithermal neutron spectrum. Based on the fitting method the a parameter was determined of 0.0267,0.0255 and -0.0346 at system rabbit, IP2 and CIP irradiation position. The k 0 factor is depended on absolute gamma fraction. The neutron flux thermal to epithermal ratio f at all rabbit system is closed to 40. (author)

  10. Analysis and databasing software for integrated tomographic gamma scanner (TGS) and passive-active neutron (PAN) assay systems

    International Nuclear Information System (INIS)

    Estep, R.J.; Melton, S.G.; Buenafe, C.

    2000-01-01

    The CTEN-FIT program, written for Windows 9x/NT in C++,performs databasing and analysis of combined thermal/epithermal neutron (CTEN) passive and active neutron assay data and integrates that with isotopics results and gamma-ray data from methods such as tomographic gamma scanning (TGS). The binary database is reflected in a companion Excel database that allows extensive customization via Visual Basic for Applications macros. Automated analysis options make the analysis of the data transparent to the assay system operator. Various record browsers and information displays simplify record keeping tasks

  11. The use of multi-energy-group neutron diffusion theory to numerically evaluate the relative utility of three dial-detector neutron porosity well logging tools

    International Nuclear Information System (INIS)

    Zalan, T.A.

    1988-01-01

    Multi-energy-group neutron diffusion theory is used to numerically evaluate the utility of two different dual-detector neutron porosity logging devices, a 14 MeV (accelerator) neutron source - epithermal neutron detector device and a 4 MeV neutron source - capture gamma-ray detector device, relative to the traditional 4 MeV neutron source - thermal neutron detector device. Fast and epithermal neutron diffusion parameters are calculated using Monte Carlo - derived neutron flux distributions. Thermal parameters are calculated from tabulated cross sections. An existing analytical method to describe the transport of gamma-rays through common earth materials is modified in order to accommodate the modeling of the 4 MeV neutron - capture gamma-ray device. The 14 MeV neutron - epithermal neutron device is found to be less sensitive to porosity than the 4 MeV neutron - capture gamma-ray device, which in turn is found to be less sensitive to porosity than the traditional 4 MeV neutron - thermal neutron device. Salinity effects are found to be comparable for the 4 MeV neutron - capture gamma-ray and 4 MeV neutron - thermal neutron devices. The 4 MeV neutron capture gamma-ray measurement is found to be deepest investigating

  12. An Assessment of Elemental Compositions and Concentrations in a Marble Sample from Hatnub Area using Internal Mono Standard Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Soliman, N.F.; EL-Shershaby, A.; EL-Bahi, S.; Walley El-Dine, N.; Abd El-Halim, E.S.; Afifi, S.

    2012-01-01

    A marble sample was taken from Hatnub area near Asyot, where a high pollution is expected. The sample was specially treated and prepared for elemental analysis using the k 0 -based internal mono standard neutron activation analysis . The irradiation facility of the first Egyptian Training Research Reactor (ETRR-1) was used to irradiate the sample together with gold and zirconium monitor samples. The pneumatic irradiation rabbit system (PIRS) built in the vertical thermal column of the second Egyptian Training Research Reactor (ETRR-2) was used to irradiate another weight of the marble sample and a sample from a certificated reference material JB-1 for short time irradiation. A new method was developed to measure the thermal to epithermal neutron flux ratio and the deviation in the real epithermal neutron spectrum ( 1/E 1±a lpha ) from the ideal (1/E ). The elemental analysis was carried out by high-resolution gamma-ray spectrometry. The accuracy of the internal mono standard method has been evaluated by analyzing the JB-1 certified reference material

  13. SU-F-T-183: Design of a Beam Shaping Assembly of a Compact DD-Based Boron Neutron Capture Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, M; Liu, Y; Nie, L [Purdue University, West Lafayette, Indiana (United States)

    2016-06-15

    Purpose: To design a beam shaping assembly (BSA) to shape the 2.45-MeV neutrons produced by a deuterium-deuterium (DD) neutron generator and to optimize the beam output for boron neutron capture therapy of brain tumors Methods: MCNP is used for this simulation study. The simulation model consists of a neutron surface source that resembles an actual DD source and is surrounded by a BSA. The neutron source emits 2.45-MeV neutrons isotropically. The BSA is composed of a moderator, reflector, collimator and filter. Various types of materials and geometries are tested for each component to optimize the neutron output. Neutron characteristics are measured with an 2×2×2-cm{sup 3} air-equivalent cylinder at the beam exit. The ideal BSA is determined by evaluating the in-air parameters, which include epithermal neutron per source neutron, fast neutron dose per epithermal neutron, and photon dose per epithermal neutron. The parameter values are compared to those recommended by the IAEA. Results: The ideal materials for reflector and thermal neutron filter were lead and cadmium, respectively. The thickness for reflector was 43 cm and for filter was 0.5 mm. At present, the best-performing moderator has 25 cm of AlF{sub 3} and 5 cm of MgF{sub 2}. This layout creates a neutron spectrum that has a peak at approximately 10 keV and produces 1.35E-4 epithermal neutrons per source neutron per cm{sup 2}. Additional neutron characteristics, fast neutrons per epithermal neutron and photon per epithermal neutron, are still under investigation. Conclusion: Working is ongoing to optimize the final layout of the BSA. The neutron spectrum at the beam exit window of the final configuration will have the maximum number of epithermal neutrons and limited photon and fast neutron contaminations within the recommended values by IAEA. Future studies will also include phantom experiments to validate the simulation results.

  14. Experiences of reconstruction of the epithermal neutron beam at THOR

    International Nuclear Information System (INIS)

    Liu Hongming; Hsu Pinchieh; Liu Chaochin; Jiang Shianghuei; Liu Yenwan Hsueh; Kai Jijung

    2006-01-01

    Tsing Hua Open-pool Reactor (THOR) had completed the renovation for an epithermal neutron beam in August 2004. The major tasks for this renovation were moderator/filter design and assembling, and concrete cutting for a better beam quality and larger irradiation room. Besides moderator/filter design, the associated works involved radiation monitoring, structure analysis, and shielding design. The radiation monitoring was performed to predict the probable accumulated dose for the workers involved in this reconstruction project. Special shielding design and construction processes were adopted to lower the radiation level and the probable accumulated dose for the workers. Before concrete cutting, structure analysis based on SAP-2000 code was performed to assure the structure is safe from the earthquake in Taiwan. A wall saw was then used for concrete cutting to enlarge the space of the irradiation room. Moderator/filter components were assembled on a trolley outside the beam exit prior to installation, which can effectively reduce the duration of a worker staying inside the reconstruction area and thereby reduce the accumulated dose. The shielding for the irradiation room was designed based on MCNP simulation using a pre-calculated source plane at the beam exit. The thickness of the concrete (density=3 g/cm 3 ) of the walls and ceiling of the irradiation room were designed to be 100cm. On-going tasks include beam parameters measurement and in vitro/ in vivo study and calibration of treatment planning system, with the hope that the team can be ready for clinical trials in 2-3 years. (author)

  15. Investigation of Six Geological Samples From Wady Sitra Eastern Desert - Egypt Using K0 Neutron Activation Method

    International Nuclear Information System (INIS)

    Soliman, N.F.; Ashmawy, L.S.; Walley El-Dine, N.; Sroor, A.; Mohamed, T.El.

    2010-01-01

    k 0 - Neutron Activation Analysis (k 0 -NAA) is applied to investigate six geological samples collected from Wady Sitra at Eastern desert of Egypt during the survey of gold presence in this area. The samples together with a group of standard (Mo, Fe, Sb and W) are irradiated for 3 hours in one of the inner irradiation site of the Second Egyptian Training and Research Reactor (ETRR-2) operating at power of 19 MW. Mo, Fe and Sb are used to measure the neutron spectrum parameters α(epithermal non-ideality factor) and f (the thermal to epithermal flux ratio) while W is used to test the obtained results. The α( and f parameters are measured using the so-called bare triple monitor method and the obtained results was found to be f = 17.5 ± 0.35 and α(= 0.03±0.002. A Fortran computer program is designed and used to calculate the values of Q 0 (α)for the analyzed elements . The concentration values of 25 elements in the present rock samples have been presented

  16. Improved Dose Targeting for a Clinical Epithermal Neutron Capture Beam Using Optional 6Li Filtration

    International Nuclear Information System (INIS)

    Binns, Peter J.; Riley, Kent J.; Ostrovsky, Yakov; Gao Wei; Albritton, J. Raymond; Kiger, W.S.; Harling, Otto K.

    2007-01-01

    Purpose: The aim of this study was to construct a 6 Li filter and to improve penetration of thermal neutrons produced by the fission converter-based epithermal neutron beam (FCB) for brain irradiation during boron neutron capture therapy (BNCT). Methods and Materials: Design of the 6 Li filter was evaluated using Monte Carlo simulations of the existing beam line and radiation transport through an ellipsoidal water phantom. Changes in beam performance were determined using three figures of merit: (1) advantage depth (AD), the depth at which the total biologically weighted dose to tumor equals the maximum weighted dose to normal tissue; (2) advantage ratio (AR), the ratio of the integral tumor dose to that of normal tissue averaged from the surface to the AD; and (3) advantage depth dose rate (ADDR), the therapeutic dose rate at the AD. Dosimetry performed with the new filter installed provided calibration data for treatment planning. Past treatment plans were recalculated to illustrate the clinical potential of the filter. Results: The 8-mm-thick Li filter is more effective for smaller field sizes, increasing the AD from 9.3 to 9.9 cm, leaving the AR unchanged at 5.7 but decreasing the ADDR from 114 to 55 cGy min -1 for the 12 cm diameter aperture. Using the filter increases the minimum deliverable dose to deep seated tumors by up to 9% for the same maximum dose to normal tissue. Conclusions: Optional 6 Li filtration provides an incremental improvement in clinical beam performance of the FCB that could help to establish a therapeutic window in the future treatment of deep-seated tumors

  17. Application of the neutron activation analysis technique in trace elements analysis

    International Nuclear Information System (INIS)

    Khamis, I.; Sarheel, A.; Al-Somel, N.

    2006-12-01

    The main objective in this study is the implementation k 0 -standardization method (single comparator method) using gold comparator as a routine method in neutron activation analysis laboratory in Engineering Nuclear Department. Cadmium ratio Rcd; Cd-ratio = [A s p/(A s p) C d] and the nuclear reactor constants (f=φ t h/φ e pi subcadimum thermal- to- epithermal neutron flux ratio and α with describing the φ e (E)∼ 1/E 1+α neutron flux distribution) were determined in the inner and outer irradiation sites at MNS Reactor. K 0 -IAEA software, which provided by the Agency, has been installed and applied in our laboratory. Trace elements in many kinds of samples (biological, environmental, alloy ...etc) were determined using K 0 -IAEA software. The results of standard reference materials (SRM's) obtained in this work show a good agreement with the certified values, and we got these results with a good accuracy closer to results which we got from relative NAA method. (author)

  18. Accelerator Based Neutron Beams for Neutron Capture Therapy

    International Nuclear Information System (INIS)

    Yanch, Jacquelyn C.

    2003-01-01

    The DOE-funded accelerator BNCT program at the Massachusetts Institute of Technology has resulted in the only operating accelerator-based epithermal neutron beam facility capable of generating significant dose rates in the world. With five separate beamlines and two different epithermal neutron beam assemblies installed, we are currently capable of treating patients with rheumatoid arthritis in less than 15 minutes (knee joints) or 4 minutes (finger joints) or irradiating patients with shallow brain tumors to a healthy tissue dose of 12.6 Gy in 3.6 hours. The accelerator, designed by Newton scientific Incorporated, is located in dedicated laboratory space that MIT renovated specifically for this project. The Laboratory for Accelerator Beam Applications consists of an accelerator room, a control room, a shielded radiation vault, and additional laboratory space nearby. In addition to the design, construction and characterization of the tandem electrostatic accelerator, this program also resulted in other significant accomplishments. Assemblies for generating epithermal neutron beams were designed, constructed and experimentally evaluated using mixed-field dosimetry techniques. Strategies for target construction and target cooling were implemented and tested. We demonstrated that the method of submerged jet impingement using water as the coolant is capable of handling power densities of up to 6 x 10(sup 7) W/m(sup 2) with heat transfer coefficients of 10(sup 6)W/m(sup 2)-K. Experiments with the liquid metal gallium demonstrated its superiority compared with water with little effect on the neutronic properties of the epithermal beam. Monoenergetic proton beams generated using the accelerator were used to evaluate proton RBE as a function of LET and demonstrated a maximum RBE at approximately 30-40 keV/um, a finding consistent with results published by other researchers. We also developed an experimental approach to biological intercomparison of epithermal beams and

  19. Notes on neutron flux measurement

    International Nuclear Information System (INIS)

    Alcala Ruiz, F.

    1984-01-01

    The main purpose of this work is to get an useful guide to carry out topical neutron flux measurements. Although the foil activation technique is used in the majority of the cases, other techniques, such as those based on fission chambers and self-powered neutron detectors, are also shown. Special interest is given to the description and application of corrections on the measurement of relative and absolute induced activities by several types of detectors (scintillators, G-M and gas proportional counters). The thermal arid epithermal neutron fluxes, as determined in this work, are conventional or effective (West cots fluxes), which are extensively used by the reactor experimentalists; however, we also give some expressions where they are related to the integrated neutron fluxes, which are used in neutron calculations. (Author) 16 refs

  20. Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments.

    Science.gov (United States)

    Miller, Marcelo E; Sztejnberg, Manuel L; González, Sara J; Thorp, Silvia I; Longhino, Juan M; Estryk, Guillermo

    2011-12-01

    A rhodium self-powered neutron detector (Rh SPND) has been specifically developed by the Comisión Nacional de Energía Atómica (CNEA) of Argentina to measure locally and in real time thermal neutron fluxes in patients treated with boron neutron capture therapy (BNCT). In this work, the thermal and epithermal neutron response of the Rh SPND was evaluated by studying the detector response to two different reactor spectra. In addition, during clinical trials of the BNCT Project of the CNEA, on-line neutron flux measurements using the specially designed detector were assessed. The first calibration of the detector was done with the well-thermalized neutron spectrum of the CNEA RA-3 reactor thermal column. For this purpose, the reactor spectrum was approximated by a Maxwell-Boltzmann distribution in the thermal energy range. The second calibration was done at different positions along the central axis of a water-filled cylindrical phantom, placed in the mixed thermal-epithermal neutron beam of CNEA RA-6 reactor. In this latter case, the RA-6 neutron spectrum had been well characterized by both calculation and measurement, and it presented some marked differences with the ideal spectrum considered for SPND calibrations at RA-3. In addition, the RA-6 neutron spectrum varied with depth in the water phantom and thus the percentage of the epithermal contribution to the total neutron flux changed at each measurement location. Local (one point-position) and global (several points-positions) and thermal and mixed-field thermal neutron sensitivities were determined from these measurements. Thermal neutron flux was also measured during BNCT clinical trials within the irradiation fields incident on the patients. In order to achieve this, the detector was placed on patient's skin at dosimetric reference points for each one of the fields. System stability was adequate for this kind of measurement. Local mixed-field thermal neutron sensitivities and global thermal and mixed

  1. Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Marcelo E.; Sztejnberg, Manuel L.; Gonzalez, Sara J.; Thorp, Silvia I.; Longhino, Juan M.; Estryk, Guillermo [Comision Nacional de Energia Atomica, Av. del Libertador 8250, Ciudad de Buenos Aires 1429 (Argentina); Comision Nacional de Energia Atomica, Av. del Libertador 8250, Ciudad de Buenos Aires 1429, Argentina and CONICET, Av. Rivadavia 1917, Ciudad de Buenos Aires 1033 (Argentina); Comision Nacional de Energia Atomica, Av. del Libertador 8250, Ciudad de Buenos Aires 1429 (Argentina)

    2011-12-15

    Purpose: A rhodium self-powered neutron detector (Rh SPND) has been specifically developed by the Comision Nacional de Energia Atomica (CNEA) of Argentina to measure locally and in real time thermal neutron fluxes in patients treated with boron neutron capture therapy (BNCT). In this work, the thermal and epithermal neutron response of the Rh SPND was evaluated by studying the detector response to two different reactor spectra. In addition, during clinical trials of the BNCT Project of the CNEA, on-line neutron flux measurements using the specially designed detector were assessed. Methods: The first calibration of the detector was done with the well-thermalized neutron spectrum of the CNEA RA-3 reactor thermal column. For this purpose, the reactor spectrum was approximated by a Maxwell-Boltzmann distribution in the thermal energy range. The second calibration was done at different positions along the central axis of a water-filled cylindrical phantom, placed in the mixed thermal-epithermal neutron beam of CNEA RA-6 reactor. In this latter case, the RA-6 neutron spectrum had been well characterized by both calculation and measurement, and it presented some marked differences with the ideal spectrum considered for SPND calibrations at RA-3. In addition, the RA-6 neutron spectrum varied with depth in the water phantom and thus the percentage of the epithermal contribution to the total neutron flux changed at each measurement location. Local (one point-position) and global (several points-positions) and thermal and mixed-field thermal neutron sensitivities were determined from these measurements. Thermal neutron flux was also measured during BNCT clinical trials within the irradiation fields incident on the patients. In order to achieve this, the detector was placed on patient's skin at dosimetric reference points for each one of the fields. System stability was adequate for this kind of measurement. Results: Local mixed-field thermal neutron sensitivities and

  2. Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments

    International Nuclear Information System (INIS)

    Miller, Marcelo E.; Sztejnberg, Manuel L.; Gonzalez, Sara J.; Thorp, Silvia I.; Longhino, Juan M.; Estryk, Guillermo

    2011-01-01

    Purpose: A rhodium self-powered neutron detector (Rh SPND) has been specifically developed by the Comision Nacional de Energia Atomica (CNEA) of Argentina to measure locally and in real time thermal neutron fluxes in patients treated with boron neutron capture therapy (BNCT). In this work, the thermal and epithermal neutron response of the Rh SPND was evaluated by studying the detector response to two different reactor spectra. In addition, during clinical trials of the BNCT Project of the CNEA, on-line neutron flux measurements using the specially designed detector were assessed. Methods: The first calibration of the detector was done with the well-thermalized neutron spectrum of the CNEA RA-3 reactor thermal column. For this purpose, the reactor spectrum was approximated by a Maxwell-Boltzmann distribution in the thermal energy range. The second calibration was done at different positions along the central axis of a water-filled cylindrical phantom, placed in the mixed thermal-epithermal neutron beam of CNEA RA-6 reactor. In this latter case, the RA-6 neutron spectrum had been well characterized by both calculation and measurement, and it presented some marked differences with the ideal spectrum considered for SPND calibrations at RA-3. In addition, the RA-6 neutron spectrum varied with depth in the water phantom and thus the percentage of the epithermal contribution to the total neutron flux changed at each measurement location. Local (one point-position) and global (several points-positions) and thermal and mixed-field thermal neutron sensitivities were determined from these measurements. Thermal neutron flux was also measured during BNCT clinical trials within the irradiation fields incident on the patients. In order to achieve this, the detector was placed on patient's skin at dosimetric reference points for each one of the fields. System stability was adequate for this kind of measurement. Results: Local mixed-field thermal neutron sensitivities and global

  3. The Comparison Study of Neutron Activation Analysis and Fission Track Technique for Uranium Determination

    International Nuclear Information System (INIS)

    Sirinuntavid, Alice; Rodthongkom, Chouvana

    2007-08-01

    Full text: Comparison between Neutron Activation Analysis (NAA) and fission track technique for uranium determination in solid samples was studied by use of standard reference materials, i.e., ore, coal fly ash, soil. For NAA, the epithermal neutron was applied for activated irradiation. Then, the 74.5 keV gamma from U-239 or 277.7 keV gamma from Np-239 was measured. For high Uranium content samples, NAA method with 74.5 keV gamma measurement, gave higher precision result than the 277.7 keV gamma measurement method. NAA method with 277.7 keV gamma measurement, gave higher sensitivity and precision result for low Uranium content samples and the uranium contained less than 10 ppm samples. Nevertheless, the latter procedure needed longer time for neutron irradiation and analysis procedure. In comparison the results of Uranium analysis between NAA and fission track, it was found that no significant difference within 95 % of confidence level

  4. Determination of rare earths and traces of other elements by neutron activation analysis

    International Nuclear Information System (INIS)

    Atalla, L.T.; Mantovani, M.S.M.; Marques, L.S.

    A complete methodology for a multielemental analysis in geological material using the neutron activation technique was developed. 21 trace elements (9 of which are rare earths) were determined using thermal and epithermal neutron irradiations. Instrumetnal and radiochemical processing, applied to BCR-1 and G-2 geological standards, are described. Statistical tests carried out on G-2 data show an error smaller than 15% referring to all elements except Cr, Sb and Yb. The observed differences between are discussed. The good precision attained in this method is confirmed by its application to BCR-1 standard, which presents errors smaller than 4% for all elements except Nd, due to its intrinsic properties. The results from the present work are compared with those from other laboratories. (C.L.B.) [pt

  5. Pulsed neutron uranium borehole logging with prompt fission neutrons

    International Nuclear Information System (INIS)

    Bivens, H.M.; Smith, G.W.; Jensen, D.H.

    1976-01-01

    The gross count natural gamma log normally used for uranium borehole logging is seriously affected by disequilibrium. Methods for the direct measurement of uranium, such as neutron logging, which are not affected by disequilibrium have been the object of considerable effort in recent years. This paper describes a logging system for uranium which uses a small accelerator to generate pulses of 14 MeV neutrons to detect and assay uranium by the measurement of prompt fission neutrons in the epithermal energy range. After an initial feasibility study, a prototype logging probe was built for field evaluation which began in January 1976. Physical and operational characteristics of the prototype probe, the neutron tube-transformer assembly, and the neutron tube are described. In logging operations, only the epithermal prompt fission neutrons detected between 250 microseconds to 2500 microseconds following the excitation neutron pulse are counted. Comparison of corrected neutron logs with the conventional gross count natural gamma logs and the chemical assays of cores from boreholes are shown. The results obtained with this neutron probe clearly demonstrate its advantages over the gross count natural gamma log, although at this time the accuracy of the neutron log assay is not satisfactory under some conditions. The necessary correction factors for various borehole and formation parameters are being determined and, when applied, should improve the assay accuracy

  6. Neutron dosimetry in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Fairchild, R.G.; Miola, U.J.; Ettinger, K.V.

    1981-01-01

    The recent development of various borated compounds and the utilization of one of these (Na 2 B 12 H 11 SH) to treat brain tumors in clinical studies in Japan has renewed interest in neutron capture therapy. In these procedures thermal neutrons interact with 10 B in boron containing cells through the 10 B(n,α) 7 Li reaction producing charged particles with a maximum range of approx. 10μm in tissue. Borated analogs of chlorpromazine, porphyrin, thiouracil and deoxyuridine promise improved tumor uptake and blood clearance. The therapy beam from the Medical Research Reactor in Brookhaven contains neutrons from a modified and filtered fission spectrum and dosimetric consequences of the use of the above mentioned compounds in conjunction with thermal and epithermal fluxes are discussed in the paper. One of the important problems of radiation dosimetry in capture therapy is determination of the flux profile and, hence, the dose profile in the brain. This has been achieved by constructing a brain phantom made of TE plastic. The lyoluminescence technique provides a convenient way of monitoring the neutron flux distributions; the detectors for this purpose utilize 6 Li and 10 B compounds. Such compounds have been synthesized specially for the purpose of dosimetry of thermal and epithermal beams. In addition, standard lyoluminescent phosphors, like glutamine, could be used to determine the collisional component of the dose as well as the contribution of the 14 N(n,p) 14 C reaction. Measurements of thermal flux were compared with calculations and with measurements done with activation foils

  7. Proton linacs for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Lennox, A.J.

    1993-08-01

    Recent advances in the ability to deliver boron-containing drugs to brain tumors have generated interest in ∼4 MeV linacs as sources of epithermal neutrons for radiation therapy. In addition, fast neutron therapy facilities have been studying methods to moderate their beams to take advantage of the high cross section for epithermal neutrons on boron-10. This paper describes the technical issues involved in each approach and presents the motivation for undertaking such studies using the Fermilab linac. the problems which must be solved before therapy can begin are outlined. Status of preparatory work and results of preliminary measurements are presented

  8. Neutron beams for therapy

    International Nuclear Information System (INIS)

    Kuplenikov, Eh.L.; Dovbnya, A.N.; Telegin, Yu.N.; Tsymbal, V.A.; Kandybej, S.S.

    2011-01-01

    It was given the analysis and generalization of the study results carried out during some decades in many world countries on application of thermal, epithermal and fast neutrons for neutron, gamma-neutron and neutron-capture therapy. The main attention is focused on the practical application possibility of the accumulated experience for the base creation for medical research and the cancer patients effective treatment.

  9. Different methodologies in neutron activation to approach the full analysis of environmental and nutritional samples

    International Nuclear Information System (INIS)

    Freitas, M.C.; Dionisio, I.; Dung, H.M.

    2008-01-01

    Different methodologies of neutron activation analysis (NAA) are now available at the Technological and Nuclear Institute (Sacavem, Portugal), namely Compton suppression, epithermal activation, replicate and cyclic activation, and low energy photon measurement. Prompt gamma activation analysis (PGAA) will be implemented soon. Results by instrumental NAA and PGAA on environmental and nutritional samples are discussed herein, showing that PGAA - carried out at the Institute of Isotope Research (Budapest, Hungary) - brings about an effective input to assessing relevant elements. Sensitivity enhancement in NAA by Compton suppression is also illustrated. Through a judicious combination of methodologies, practically all elements of interest in pollution and nutrition terms can be determined. (author)

  10. Neutron flux of 100kW in the irradiation terminals of the IPR-R1 Triga Reactor

    International Nuclear Information System (INIS)

    Zangirolami, Dante Marco

    2009-01-01

    In this work, it was carried out a study of the neutron flux in the IPR-R1 TRIGA reactor irradiation facilities: rotary specimen rack (RSR), pneumatic transfer tube two (PTT2) and the central thimble (CT). The objective was to obtain the neutron flux profile on the RSR, which has forty irradiation positions, and also values for the thermal and epithermal neutron fluxes of some RSR positions and also of the PTT2 and of the CT facility. It was applied the neutron activation analysis of a reference material, Al-Au (0.1%) alloy. Irradiations were performed on 16 different dates. It was concluded that for the RSR, the average value of thermal and epithermal neutron fluxes depends on the vertical position of the reactor control rods. Neutron flux variations along the RSR form a characteristic profile, whose values depend on the location of the irradiation position in the reactor core and on the control rods vertical position. In the RSR, the obtained values of thermal and epithermal neutron flux were (8.1 +- 0.3) x 10 11 n.cm -2 .s -1 , and (3.4 +- 0.2)x10 10 n.cm -2 .s -1 , respectively. For the PTT2 and the CT, the values for the epithermal neutron flux were respectively (3.3 +- 0.2) x 10 9 n.cm -2 .s -1 and (2.6 +- 0.1) x 10 11 n.cm -2 .s -1 . For these facilities, the thermal neutron flux was estimated, and the obtained values were (2.4 +- 0.2) x 10 11 n.cm -2 .s -1 and (2.8 +- 0.1)x10 12 n.cm -2 .s -1 for the PTT2 and the CT, respectively. (author)

  11. Development of an anthropomorfic simulator for simulation and measurements of neutron dose and flux the facility for BNCT studies

    International Nuclear Information System (INIS)

    Muniz, Rafael Oliveira Rondon

    2010-01-01

    IPEN facility for researches in BNCT (Boron Neutron Capture Therapy) uses IEA-R1 reactor's irradiation channel number 3, where there is a mixed radiation field - neutrons and gamma. The researches in progress require the radiation fields, in the position of the irradiation of sample, to have in its composition maximized thermal neutrons component and minimized, fast and epithermal neutron flux and gamma radiation. This work was developed with the objective of evaluating whether the present radiation field in the facility is suitable for BNCT researches. In order to achieve this objective, a methodology for the dosimetry of thermal neutrons and gamma radiation in mixed fields of high doses, which was not available in IPEN, was implemented in the Center of Nuclear Engineering of IPEN, by using thermoluminescent dosimeters - TLDs 400, 600 and 700. For the measurements of thermal and epithermal neutron flux, activation detectors of gold were used applying the cadmium ratio technique. A cylindrical phantom composed by acrylic discs was developed and tested in the facility and the DOT 3.5. computational code was used in order to obtain theoretical values of neutron flux and the dose along phantom. In the position corresponding to about half the length of the cylinder of the phantom, the following values were obtained: thermal neutron flux (2,52 ± 0,06).10 8 n/cm 2 s, epithermal neutron flux (6,17 ± 0,26).10 7 .10 6 n/cm 2 s, absorbed dose due to thermal neutrons (4,2 ± 1,8)Gy and (10,1 ± 1,3)Gy due to gamma radiation. The obtained values show that the fluxes of thermal and epithermal neutrons flux are appropriate for studies in BNCT, however, the dose due to gamma radiation is high, indicating that the facility should be improved. (author)

  12. Use of Germanium as comparator and integral monitor of neutron flux in activation analysis

    International Nuclear Information System (INIS)

    Furnari, Juan C.; Cohen, Isaac M.; Arribere, Maria A.; Kestelman, Abraham J.

    1997-01-01

    The possibility of using germanium as monitor of the thermal and epithermal components of the neutron flux, and comparator in parametric activation analysis, is discussed. The advantages and drawbacks associated to the use of this element are commented on, and the comparison with zirconium, in terms of the determination relative error, is performed. The utilisation of germanium as integral flux monitor, including the fast component of the neutron spectrum, is also discussed. Data corresponding to measurements of k 0 factor for the most relevant gamma transitions from Ge-75 and Be-77 are presented, as well as the results of the reference material analysis, employing germanium as flux monitor and comparator in a simultaneous way. (author). 8 refs., 3 figs., 2 tabs

  13. Neutron flux determination at the IPR-R1 Triga Mark I neutron beam extractor

    International Nuclear Information System (INIS)

    Zangirolami, Dante Marco; Maretti Junior, Fausto; Ferreira, Andrea Vidal

    2009-01-01

    The IPR-R1 Triga Mark I Reactor located at the CDTN/CNEN, Belo Horizonte, Brazil, has been operating since November of 1960. In this work, measurements of thermal and epithermal neutron flux along the IPR-R1 neutron beam extractor were performed by neutron activation of reference materials using the two foils method. The obtained results were compared with results from two previous works: an experimental measurement done in a previous reactor core configuration and a numerical work made by Monte Carlo simulation using the actual reactor core configuration. The main purpose of this work is to update the measured data to the actual reactor core configuration. (author)

  14. Uses of reactor neutrons for studying the microcomposition of materials

    International Nuclear Information System (INIS)

    Jervis, R.E.

    1993-01-01

    Reactor neutrons constitute excellents 'probes' for exploring and measuring a wide range both of minor and trace constituents in solids and liquids with high sensitivity because of their transparency in materials. Nondestructive neutron prompt-gamma analysis (PGA) utilizing either cold or thermal neutrons, such as at JRR-3M, is compared and contrasted to the more common (delayed) instrumental neutron activation analysis (INAA) and epithermal NAA. Clearly PGA offers high sensitivity for selected elements: B, H, Cd and REE's in suitable matrices, and is therefore, complementary to INAA which is not as useful for them, or for Ni, Sn, Fe, C or N. Recent INAA applications in our laboratory that demonstrate some of the uniqueness of neutron methods include use of epithermal neutrons for small biological specimens to measure Cd, K, As, Zn and, multielemental INAA for environmental pollution studies. The latter involves large data sets of multielemental concentrations which are subjected to statistical multivariant factor analysis to reveal unknown or unsuspected quantitative relationships among groups of trace constituents. These patterns, or 'factors' are shown to be uniquely related to pollution sources and can be utilized to compute the relative source contributions at a given receptor site. (author)

  15. Estimation of total as well as bioaccessible levels and average daily dietary intake of iodine from Japanese edible seaweeds by epithermal neutron activation analysis

    International Nuclear Information System (INIS)

    Fukushima, M.; Chatt, A.

    2012-01-01

    An epi-thermal instrumental neutron activation analysis (EINAA) method in conjunction with Compton suppression spectrometry (EINAA-CSS) was used for the determination of total iodine in eight different species of edible seaweeds from Japan. This method gave an absolute detection limit of about 2 μg. The accuracy of the method was evaluated using various reference materials and found to be generally in agreement within ±6% of the certified values. The longitudinal distributions of iodine at different growing stages in Japanese sea mustard and tangle seaweeds were investigated. For a 150-cm-high tangle, the highest concentration (5,360 mg/kg) of iodine was found at the root, then decreased slowly to 780 mg/kg in the middle portion (60-75 cm), and increased to 2,300 mg/kg at the apex. On the other hand, for a 190-cm-high sea mustard the highest levels of iodine were found both at the roots (164 mg/kg) and apex (152 mg/kg) with lower values (98 mg/kg) in the middle section. In order to estimate the bioaccessible fraction of iodine, seaweeds were digested by an in vitro enzymolysis method, dietary fibre separated from residue, and both fractions analyzed by EINAA-CSS. The average daily dietary intakes of total (0.14 mg) as well as bioaccessible fraction (0.12 mg) of iodine from the consumption of sea mustards were estimated. (author)

  16. Neutron spectrum for neutron capture therapy in boron; Espectro de neutrones para terapia por captura de neutrones en boro

    Energy Technology Data Exchange (ETDEWEB)

    Medina C, D.; Soto B, T. G. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Programa de Doctorado en Ciencias Basicas, 98068 Zacatecas, Zac. (Mexico); Baltazar R, A. [Universidad Autonoma de Zacatecas, Unidad Academica de Ingenieria Electrica, Programa de Doctorado en Ingenieria y Tecnologia Aplicada, 98068 Zacatecas, Zac. (Mexico); Vega C, H. R., E-mail: dmedina_c@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico)

    2016-10-15

    Glioblastoma multiforme is the most common and aggressive of brain tumors and is difficult to treat by surgery, chemotherapy or conventional radiation therapy. One treatment alternative is the Neutron Capture Therapy in Boron, which requires a beam modulated in neutron energy and a drug with {sup 10}B able to be fixed in the tumor. When the patients head is exposed to the neutron beam, they are captured by the {sup 10}B and produce a nucleus of {sup 7}Li and an alpha particle whose energy is deposited in the cancer cells causing it to be destroyed without damaging the normal tissue. One of the problems associated with this therapy is to have an epithermal neutrons flux of the order of 10{sup 9} n/cm{sup 2}-sec, whereby irradiation channels of a nuclear research reactor are used. In this work using Monte Carlo methods, the neutron spectra obtained in the radial irradiation channel of the TRIGA Mark III reactor are calculated when inserting filters whose position and thickness have been modified. From the arrangements studied, we found that the Fe-Cd-Al-Cd polyethylene filter yielded a ratio between thermal and epithermal neutron fluxes of 0.006 that exceeded the recommended value (<0.05), and the dose due to the capture gamma rays is lower than the dose obtained with the other arrangements studied. (Author)

  17. Secondary neutron production from thick Pb target by light particle irradiation

    CERN Document Server

    Adloff, J C; Debeauvais, M; Fernández, F; Krivopustov, M; Kulakov, B A; Sosnin, A; Zamani, M

    1999-01-01

    Neutron multiplicities from spallation neutron sources were measured by Solid State Nuclear Track Detectors. Light particles as protons, deuterons and alphas in the GeV range were used on Pb targets. For neutron thermalization the targets were covered by 6 cm paraffin moderator. Neutron multiplicity distributions were studied inside and on the moderator surface. Comparison of SSNTDs results were made for thermal-epithermal neutrons with sup 1 sup 3 sup 9 La activation method as well as with Dubna DCM/CEM code. Discussion including previous sup 1 sup 2 C results are given.

  18. neutron radiography

    International Nuclear Information System (INIS)

    Barton, J.P.

    1993-01-01

    Neutron radiography (or radiology) is a diverse filed that uses neutrons of various energies, subthermal, thermal, epithermal or fast in either steady state or pulsed mode to examine objects for industrial, medical, or other purposes, both microscopic and macroscopic. The applications include engineering design, biological studies, nondestructive inspection and materials evaluation. In the past decade, over 100 different centers in some 30 countries have published reports of pioneering activities using reactors, accelerators and isotopic neutron sources. While film transparency and electronic video are most common imaging methods for static or in motion objects respectively, there are other important data gathering techniques, including track etch, digital gauging and computed tomography. A survey of the world-wide progress shows the field to be gaining steadily in its diversity, its sophistication and its importance. (author)

  19. Desain Beam Shaping Assembly (BSA berbasis D-D Neutron Generator 2,45 MeV untuk Uji Fasilitas BNCT

    Directory of Open Access Journals (Sweden)

    Desman P. Gulo

    2015-12-01

    Full Text Available Boron Neutron Capture Therapy (BNCT is one of the cancer treatments that are being developed in nowadays. In order to support BNCT treatment for cancer that exists in underneath skin like breast cancer, the facility needs a generator that is able to produce epithermal neutron. One of the generator that is able to produce neutron is D-D neutron generator with 2.45 MeV energy. Based on the calculation of this paper, we found that the total production of neutron per second (neutron yield from Neutron Generator (NG by PSTA-BATAN Yogyakarta is 2.55×1011 n/s. The energy and flux that we found is in the range of quick neutron. Thus, it needs to be moderated to the level of epithermal neutron which is located in the interval energy of 1 eV to 10 KeV with 109 n/cm2s flux. This number is the recommendation standard from IAEA. Beam Shaping Assembly (BSA is needed in order to moderate the quick neutron to the level of epithermal neutron. One part of BSA that has the responsibility in moderating the quick neutron to epithermal neutron is the moderator. The substance of moderator used in this paper is MgF2 and A1F3. The thickness of moderator has been set in in such a way by using MCNPX software in order to fulfill the standard of IAEA. As the result of optimizing BSA moderator, the data obtain epithermal flux with the total number of 4.64×108 n/cm2/s for both of moderators with the thickness of moderator up to 15 cm. At the end of this research, the number of epithermal flux does not follow the standard of IAEA. This is because the flux neutron that is being produced by NG is relatively small. In conclusion, the NG from PSTA-BATAN Yogyakarta is not ready to be used for the BNCT treatment facility for the underneath skin cancer like breast cancer.

  20. Alanine and TLD coupled detectors for fast neutron dose measurements in neutron capture therapy (NCT)

    Energy Technology Data Exchange (ETDEWEB)

    Cecilia, A.; Baccaro, S.; Cemmi, A. [ENEA-FIS-ION, Casaccia RC, Via Anguillarese 301, 00060 Santa Maria di Galeria, Rome (Italy); Colli, V.; Gambarini, G. [Dept. of Physics of the Univ., INFN, Via Celoria 16, 20133 Milan (Italy); Rosi, G. [ENEA-FIS-ION, Casaccia RC, Via Anguillarese 301, 00060 Santa Maria di Galeria, Rome (Italy); Scolari, L. [Dept. of Physics of the Univ., INFN, Via Celoria 16, 20133 Milan (Italy)

    2004-07-01

    A method was investigated to measure gamma and fast neutron doses in phantoms exposed to an epithermal neutron beam designed for neutron capture therapy (NCT). The gamma dose component was measured by TLD-300 [CaF{sub 2}:Tm] and the fast neutron dose, mainly due to elastic scattering with hydrogen nuclei, was measured by alanine dosemeters [CH{sub 3}CH(NH{sub 2})COOH]. The gamma and fast neutron doses deposited in alanine dosemeters are very near to those released in tissue, because of the alanine tissue equivalence. Couples of TLD-300 and alanine dosemeters were irradiated in phantoms positioned in the epithermal column of the Tapiro reactor (ENEA-Casaccia RC). The dosemeter response depends on the linear energy transfer (LET) of radiation, hence the precision and reliability of the fast neutron dose values obtained with the proposed method have been investigated. Results showed that the combination of alanine and TLD detectors is a promising method to separate gamma dose and fast neutron dose in NCT. (authors)

  1. Design of collimator in the radial piercing beam port of Kartini reactor for boron neutron capture therapy

    International Nuclear Information System (INIS)

    M Ilma Muslih A; Andang Widiharto; Yohannes Sardjono

    2014-01-01

    Studies were carried out to design a collimator which results in epithermal neutron beam for in vivo experiment of Boron Neutron Capture Therapy (BNCT) at the Kartini Research Reactor by means of Monte Carlo N-Particle (MCNP) codes. Reactor within 100 kW of thermal power was used as the neutron source. All materials used were varied in size, according to the value of mean free path for each material. MCNP simulations indicated that by using 5 cm thick of Ni (95%) as collimator wall, 15 cm thick of Al as moderator, 1 cm thick of Pb as γ-ray shielding, 1.5 cm thick of Boral as additional material, with 2 cm aperture diameter, epithermal neutron beam with maximum flux of 5.03 x 10 8 n.cm -2 .s -1 could be produced. The beam has minimum fast neutron and γ-ray components of, respectively, 2.17 x 10 -13 Gy.cm 2 .n -1 and 1.16 x 10 -13 Gy.cm 2 .n -l , minimum thermal neutron per epithermal neutron ratio of 0.12, and maximum directionality of 0.835 . It did not fully pass the IAEA's criteria, since the epithermal neutron flux was below the recommended value, 1.0 x 10 9 n.cm -2 .s -l . Nonetheless, it was still usable with epithermal neutron flux exceeding 5.0 x 10 8 n.cm -2 .s -1 and fast neutron flux close to 2 x 10 -13 Gy.cm 2 .n -1 it is still feasible for BNCT in vivo experiment. (author)

  2. Microdosimetry for Boron Neutron Capture Therapy

    International Nuclear Information System (INIS)

    Maughan, R.L.; Kota, C.

    2000-01-01

    The specific aims of the research proposal were as follows: (1) To design and construct small volume tissue equivalent proportional counters for the dosimetry and microdosimetry of high intensity thermal and epithermal neutron beams used in BNCT, and of modified fast neutron beams designed for boron neutron capture enhanced fast neutron therapy (BNCEFNT). (2) To develop analytical methods for estimating the biological effectiveness of the absorbed dose in BNCT and BNCEFNT based on the measured microdosimetric spectra. (3) To develop an analytical framework for comparing the biological effectiveness of different epithermal neutron beams used in BNCT and BNCEFNT, based on correlated sets of measured microdosimetric spectra and radiobiological data. Specific aims (1) and (2) were achieved in their entirety and are comprehensively documented in Jay Burmeister's Ph.D. dissertation entitled ''Specification of physical and biologically effective absorbed dose in radiation therapies utilizing the boron neutron capture reaction'' (Wayne State University, 1999). Specific aim (3) proved difficult to accomplish because of a lack of sufficient radiobiological data

  3. Halogen determination in Arctic aerosols by neutron activation analysis with Compton suppression methods

    International Nuclear Information System (INIS)

    Landsberger, S.; Basunia, M.S.; Iskander, F.

    2001-01-01

    The study of halogens particularly bromine and chlorine in Arctic aerosols has received a great deal of attention in the past decade in ozone depletion during polar sunrise studies. Iodine has also been studied as part of geochemical cycling. It was shown that all three of the above elements can be determined simultaneously with very low detection limits using epithermal NAA in conjunction with Compton suppression methods. Besides lowering the background considerably, Compton suppression can eliminate or minimize the overlapping peak of the 620 keV photopeak arising form the 1642 keV double escape peak of 38 Cl interfering with the 616.9 keV photopeak of 79 Br(n,γ) 80 Br reaction. Iodine is ideally determined by epithermal NAA because of its very good resonance integral cross-section. Although chlorine is usually determined using thermal neutrons via the 37 Cl(n,γ) 38 Cl reactions, epithermal NAA is still feasible for the Arctic aerosol, since it has a major sea-salt component. (author)

  4. Clinical considerations for neutron capture therapy of brain tumors

    International Nuclear Information System (INIS)

    Madoc-Jones, H.; Wazer, D.E.; Zamenhof, R.G.; Harling, O.K.; Bernard, J.A. Jr.

    1990-01-01

    The radiotherapeutic management of primary brain tumors and metastatic melanoma in brain has had disappointing clinical results for many years. Although neutron capture therapy was tried in the US in the 1950s and 1960s, the results were not as hoped. However, with the newly developed capability to measure boron concentrations in blood and tissue both quickly and accurately, and with the advent of epithermal neutron beams obviating the need for scalp and skull reflection, it should not be possible to mount such a clinical trial of NCT again and avoid serious complications. As a prerequisite, it will be important to demonstrate the differential uptake of boron compound in brain tumor as compared with normal brain and its blood supply. If this can be done, then a trial of boron neutron capture therapy for brain tumors should be feasible. Because boronated phenylalanine has been demonstrated to be preferentially taken up by melanoma cells through the biosynthetic pathway for melanin, there is special interest in a trial of boron neutron capture therapy for metastatic melanoma in brain. Again, the use of an epithermal beam would make this a practical possibility. However, because any epithermal (or thermal) beam must contain a certain contaminating level of gamma rays, and because even a pure neutron beam cases gamma rays to be generated when it interacts with tissue, they think that it is essential to deliver treatments with an epithermal beam for boron neutron capture therapy in fractions in order to minimize the late-effects of low-LET gamma rays in the normal tissue

  5. Neutron spectrum for neutron capture therapy in boron

    International Nuclear Information System (INIS)

    Medina C, D.; Soto B, T. G.; Baltazar R, A.; Vega C, H. R.

    2016-10-01

    Glioblastoma multiforme is the most common and aggressive of brain tumors and is difficult to treat by surgery, chemotherapy or conventional radiation therapy. One treatment alternative is the Neutron Capture Therapy in Boron, which requires a beam modulated in neutron energy and a drug with 10 B able to be fixed in the tumor. When the patients head is exposed to the neutron beam, they are captured by the 10 B and produce a nucleus of 7 Li and an alpha particle whose energy is deposited in the cancer cells causing it to be destroyed without damaging the normal tissue. One of the problems associated with this therapy is to have an epithermal neutrons flux of the order of 10 9 n/cm 2 -sec, whereby irradiation channels of a nuclear research reactor are used. In this work using Monte Carlo methods, the neutron spectra obtained in the radial irradiation channel of the TRIGA Mark III reactor are calculated when inserting filters whose position and thickness have been modified. From the arrangements studied, we found that the Fe-Cd-Al-Cd polyethylene filter yielded a ratio between thermal and epithermal neutron fluxes of 0.006 that exceeded the recommended value (<0.05), and the dose due to the capture gamma rays is lower than the dose obtained with the other arrangements studied. (Author)

  6. Use of the Power Burst Facility for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Crocker, J.G.; Griebenow, M.L.; Leatham, J.

    1990-01-01

    A program is under development at the Idaho National Engineering Laboratory (INEL) that involves using the Power Burst Facility (PBF) for research into boron neutron capture therapy (BNCT). BNCT utilizes the ionizing energy from boron-neutron capture to stop reproduction of or destroy cells in cancerous tissue in a two-step process. The first step is to selectively concentrate a boron isotope within the tumor cell, that when activated by neutron capture emits highly ionizing, short range particles. The second step involves activation of the isotope only in the vicinity of the tumor with a narrow neutron beam. The ( 10 B[n, 4 He] 7 Li) reaction with thermal neutrons produces fission products with track lengths approximately equal to a cell diameter. The INEL program includes the modification of the PBF by the addition of a filter and treatment area. The filter will down-scatter high energy neutrons into the epithermal range and remove thermal neutrons and excessively damaging gamma components. The intense source of epithermal neutrons from PBF is considered necessary to achieve optimum therapy for deep-seated tumors with minimum damage to surface tissue. THe neutron filter conceptualized for PBF utilizes aluminum and heavy water to down-scatter neutrons into the proper energy range. Bismuth will be used for gamma shielding and cadmium will remove the thermal neutron contaminant from the beam. The INEL program leads to human clinical trials at PBF which are intended to prove that brain tumors can be successfully treated through noninvasive techniques. Further research into BNCT at PBF for other cancer types is also anticipated

  7. A feasibility study of a deuterium-deuterium neutron generator-based boron neutron capture therapy system for treatment of brain tumors.

    Science.gov (United States)

    Hsieh, Mindy; Liu, Yingzi; Mostafaei, Farshad; Poulson, Jean M; Nie, Linda H

    2017-02-01

    Boron neutron capture therapy (BNCT) is a binary treatment modality that uses high LET particles to achieve tumor cell killing. Deuterium-deuterium (DD) compact neutron generators have advantages over nuclear reactors and large accelerators as the BNCT neutron source, such as their compact size, low cost, and relatively easy installation. The purpose of this study is to design a beam shaping assembly (BSA) for a DD neutron generator and assess the potential of a DD-based BNCT system using Monte Carlo (MC) simulations. The MC model consisted of a head phantom, a DD neutron source, and a BSA. The head phantom had tally cylinders along the centerline for computing neutron and photon fluences and calculating the dose as a function of depth. The head phantom was placed at 4 cm from the BSA. The neutron source was modeled to resemble the source of our current DD neutron generator. A BSA was designed to moderate and shape the 2.45-MeV DD neutrons to the epithermal (0.5 eV to 10 keV) range. The BSA had multiple components, including moderator, reflector, collimator, and filter. Various materials and configurations were tested for each component. Each BSA layout was assessed in terms of the in-air and in-phantom parameters. The maximum brain dose was limited to 12.5 Gray-Equivalent (Gy-Eq) and the skin dose to 18 Gy-Eq. The optimized BSA configuration included 30 cm of lead for reflector, 45 cm of LiF, and 10 cm of MgF 2 for moderator, 10 cm of lead for collimator, and 0.1 mm of cadmium for thermal neutron filter. Epithermal flux at the beam aperture was 1.0 × 10 5  n epi /cm 2 -s; thermal-to-epithermal neutron ratio was 0.05; fast neutron dose per epithermal was 5.5 × 10 -13  Gy-cm 2 /φ epi , and photon dose per epithermal was 2.4 × 10 -13  Gy-cm 2 /φ epi . The AD, AR, and the advantage depth dose rate were 12.1 cm, 3.7, and 3.2 × 10 -3  cGy-Eq/min, respectively. The maximum skin dose was 0.56 Gy-Eq. The DD neutron yield that is needed to

  8. Neutron activation analysis for development of mercury sorbent based on blue-green alga salipriina palatinates

    International Nuclear Information System (INIS)

    Frontasyeva, M.V.; Kirkesali, E.I.; Aksenova, N.G.; Mosulishvili, L.M.; Belokobylsky, A.I.; Khizanishvili, A.I.

    2005-01-01

    Epithermal neutron activation analysis was used to study interaction of blue-green alga Spirulina platensis with toxic metal mercury. Various concentrations of Hg(II) were added to cell cultures in a nutrient medium. The dynamic of accumulation of Hg was investigated over days in relation to Spirulina biomass growth. The process of Hg adsorption by Spirulina biomass was studied in short-time experiments. The isotherm of adsorption was / out in Freindlich coordinates. Natural Spirulina biomass has potential to be used in the remediation of sewage waters at Hg concentrations ∼ 100 μg/1

  9. Monte Carlo based dosimetry and treatment planning for neutron capture therapy of brain tumors

    International Nuclear Information System (INIS)

    Zamenhof, R.G.; Brenner, J.F.; Wazer, D.E.; Madoc-Jones, H.; Clement, S.D.; Harling, O.K.; Yanch, J.C.

    1990-01-01

    Monte Carlo based dosimetry and computer-aided treatment planning for neutron capture therapy have been developed to provide the necessary link between physical dosimetric measurements performed on the MITR-II epithermal-neutron beams and the need of the radiation oncologist to synthesize large amounts of dosimetric data into a clinically meaningful treatment plan for each individual patient. Monte Carlo simulation has been employed to characterize the spatial dose distributions within a skull/brain model irradiated by an epithermal-neutron beam designed for neutron capture therapy applications. The geometry and elemental composition employed for the mathematical skull/brain model and the neutron and photon fluence-to-dose conversion formalism are presented. A treatment planning program, NCTPLAN, developed specifically for neutron capture therapy, is described. Examples are presented illustrating both one and two-dimensional dose distributions obtainable within the brain with an experimental epithermal-neutron beam, together with beam quality and treatment plan efficacy criteria which have been formulated for neutron capture therapy. The incorporation of three-dimensional computed tomographic image data into the treatment planning procedure is illustrated

  10. Cosmic-ray neutron transport at a forest field site: the sensitivity to various environmental conditions with focus on biomass and canopy interception

    Science.gov (United States)

    Andreasen, Mie; Jensen, Karsten H.; Desilets, Darin; Zreda, Marek; Bogena, Heye R.; Looms, Majken C.

    2017-04-01

    Cosmic-ray neutron intensity is inversely correlated to all hydrogen present in the upper decimeters of the subsurface and the first few hectometers of the atmosphere above the ground surface. This correlation forms the base of the cosmic-ray neutron soil moisture estimation method. The method is, however, complicated by the fact that several hydrogen pools other than soil moisture affect the neutron intensity. In order to improve the cosmic-ray neutron soil moisture estimation method and explore the potential for additional applications, knowledge about the environmental effect on cosmic-ray neutron intensity is essential (e.g., the effect of vegetation, litter layer and soil type). In this study the environmental effect is examined by performing a sensitivity analysis using neutron transport modeling. We use a neutron transport model with various representations of the forest and different parameters describing the subsurface to match measured height profiles and time series of thermal and epithermal neutron intensities at a field site in Denmark. Overall, modeled thermal and epithermal neutron intensities are in satisfactory agreement with measurements; however, the choice of forest canopy conceptualization is found to be significant. Modeling results show that the effect of canopy interception, soil chemistry and dry bulk density of litter and mineral soil on neutron intensity is small. On the other hand, the neutron intensity decreases significantly with added litter-layer thickness, especially for epithermal neutron energies. Forest biomass also has a significant influence on the neutron intensity height profiles at the examined field site, altering both the shape of the profiles and the ground-level thermal-to-epithermal neutron ratio. This ratio increases with increasing amounts of biomass, and was confirmed by measurements from three sites representing agricultural, heathland and forest land cover. A much smaller effect of canopy interception on the ground

  11. Detection of explosives and illicit drugs using neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Kiraly, B. E-mail: kiralyb@tigris.klte.hu; Sanami, T.; Doczi, R.; Csikai, J

    2004-01-01

    A procedure developed for the determination of the flux perturbation factor required for the thermal neutron activation analysis of bulky samples of unknown composition has been extended for epithermal neutrons using hydrogenous and graphite moderators. Measurements on the diffusion and backscattering of thermal neutrons in soil components were carried out for the development of novel nuclear methods in order to speed up the humanitarian demining process. Results obtained for the diffusion length were checked by MCNP-4C calculations. In addition, the effect of the weight and density of the explosives on the observation of the anomaly in the reflected thermal neutrons was examined by using different dummy landmines.

  12. Multielement analysis of rice flour-unpolished reference material by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Hirai, Shoji

    1990-01-01

    Trace elements in NIES certified reference material No. 10-a∼10-c Rice Flour-Unpolished, prepared by the National Institute for Environmental Studies of Japan (NIES), were determined by instrumental neutron activation analysis (INAA). A set of three samples with different Cd concentration levels was subjected to analyses. Portions of each sample (ca. 200∼1000 mg) were irradiated, either with thermal neutrons without cadmium filter or with epithermal neutrons with cadmium filter, in the Musashi Institute of Technology Research Reactor (MITRR). The activated samples were analyzed by the three methods; conventional γ-ray spectrometry using a coaxial Ge detector, anticoincidence counting spectrometry, and coincidence counting spectrometry using a coaxial Ge detector and a well type NaI(Tl) detector. Concentrations of 26∼28 elements were determined by these methods. The values obtained for many elements, except for Mg and K, were in good agreement with those of the NIES certified and reference. Concentrations of 10 elements (S, Sc, V, Ag, Sb, Cs, Ba, La, Sm, Th), whose certified or reference values are not available from NIES, were also determined in this work. (author)

  13. A novel design of beam shaping assembly to use D-T neutron generator for BNCT.

    Science.gov (United States)

    Kasesaz, Yaser; Karimi, Marjan

    2016-12-01

    In order to use 14.1MeV neutrons produced by d-T neutron generators, two special and novel Beam Shaping Assemblies (BSA), including multi-layer and hexagonal lattice have been suggested and the effect of them has been investigated by MCNP4C Monte Carlo code. The results show that the proposed BSA can provide the qualified epithermal neutron beam for BNCT. The final epithermal neutron flux is about 6e9 n/cm2.s. The final proposed BSA has some different advantages: 1) it consists of usual and well-known materials (Pb, Al, Fluental and Cd); 2) it has a simple geometry; 3) it does not need any additional gamma filter; 4) it can provide high flux of epithermal neutrons. As this type of neutron source is under development in the world, it seems that they can be used clinically in a hospital considering the proposed BSA. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Determination of silver, gold, zinc and copper in mineral samples by various techniques of instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Rodriguez R, N. I.; Rios M, C.; Pinedo V, J. L.; Yoho, M.; Landsberger, S.

    2015-09-01

    Using the method of instrumental neutron activation analysis, mineral exploration samples were analyzed in order to determine the concentrations of silver, gold, zinc and copper; these minerals being the main products of benefit of Tizapa and Cozamin mines. Samples were subjected to various techniques, where the type of radiation and counting methods were chosen based on the specific isotopic characteristics of each element. For calibration and determination of concentrations the comparator method was used, certified standards were subjected to the same conditions of irradiation and measurement that the prospecting samples. The irradiations were performed at the research reactor TRIGA Mark II of the University of Texas at Austin. The silver concentrations were determined by Cyclical Epithermal Neutron Activation Analysis. This method in combination with the transfer pneumatic system allowed a good analytical precision and accuracy in prospecting for silver, from photo peak measurement 657.7 keV of short half-life radionuclide 110 Ag. For the determination of gold and zinc, Epithermal Neutron Activation Analysis was used, the photo peaks analyzed corresponded to the energies 411.8 keV of radionuclide 199 Au and 438.6 keV of metastable radionuclide 69m Zn. On the other hand, copper quantification was based on the photo peak analysis of 1039.2 keV produced by the short half-life radionuclide 66 Cu, by Thermal Neutron Activation Analysis. The photo peaks measurement corresponding to gold, zinc and copper was performed using a Compton suppression system, which allowed an improvement in the signal to noise relationship, so that better detection limits and low uncertainties associated with the results were obtained. Comparing elemental concentrations the highest values in silver, zinc and copper was for samples of mine Tizapa. Regarding gold values were found in the same range for both mines. To evaluate the precision and accuracy of the methods used, various geological

  15. Method and apparatus for formation logging using position sensitive neutron detectors

    International Nuclear Information System (INIS)

    Gadken, L.L.

    1986-01-01

    This patent describes a method for logging earth formations using position sensitive neutron detectors. The method consists of: 1) Irradiation of earth formations in the vicinity of a well borehole with a source of fast neutrons. 2) At four longitudinally spaced distances from the neutron source in the borehole, the epithermal neutron population is detected. Each of the four separate populations is detected in an epithermally sensitive and substantially thermally insensitive portion of the same position sensitive neutron detector. A representative signal from each is then individually generated. 3) First, second, third, and fourth neutron population representative signals are combined. They derive a simultaneous measurement signal. This signal is functionally related to the porosity and also a signal functionally related to a neutron characteristic length of the earth formations in the vicinity of the borehole

  16. Neutronic characterization of cylindrical core of minor excess reactivity in the nuclear reactor IPEN/MB-01 from the measure of spatial and energetic distribution of neutron flux distribution

    International Nuclear Information System (INIS)

    Aredes, Vitor Ottoni Garcia

    2014-01-01

    In this work was conducted the mapping of the thermal and epithermal neutrons flux and the energy spectrum of the neutrons in the reactor core IPEN/MB-01 for a cylindrical core configuration with minor excess reactivity, which is 28 x 28 fuel rods arranged in north-south and east-west directions. The calibration of control rods for this configuration determined their excess reactivity. The lower excess reactivity in the core decreased neutron flux disturbance caused by the neutron absorbing rods , given that the nuclear reactor was operated with the rods almost completely removed . Was used the 'Activation Analysis Technique' with the thin foil activation detectors ( infinitely diluted and hyper-pure), of different materials that work in different energy ranges, to calculate the saturation activity, used for determining the neutron flux and in the SANDBP code as input for the calculation of the neutrons energy spectrum. To discriminate thermal and epithermal flux , was used the 'Cadmium RatioTechnique' . The activation detectors were distributed in a total of 140 radial and axial positions in the reactor core and 16 irradiation, with bare and covered with cadmium activation foils. A model of this configuration was simulated by MCNP-5 code to determine the cadmium correction factor and comparison of the results obtained experimentally. The cylindrical configuration desired, with 17% less fuel than the standard rectangular configuration (28 x 26 fuel rods), reached criticality with the control rods approximately 90% removed, which decreased considerably the disturbance in neutron flux. Given the highest power density of the 28 x 28 cylindrical core, the neutron flux increased by over 50% in the central regions of the core compared to the values of the 28 x 26 standard rectangular core. (author)

  17. Procedure and code for calculating black control rods taking into account epithermal absorption, code CAS-1

    International Nuclear Information System (INIS)

    Martinc, R.; Trivunac, N.; Zivkovic, Z.

    1964-12-01

    This report describes the computer code CAS-1, calculation method and procedure applied for calculating the black control rods taking into account the epithermal neutron absorption. Results obtained for supercell method applied for regular lattice reflected in the multiplication medium is part of this report in addition to the computer code manual

  18. A prospect for the development of an epithermal neutron beam from the horizontal channel at the TRNC for brain tumors treatment based on the BNCT method

    International Nuclear Information System (INIS)

    Ben-Ghazail, Mustafa Ali

    2005-01-01

    In this work the epithermal neutron was development from horizontal channel VI at Tajoura research reactor which can be used for Boron Neutron Capture Therapy. The analysis of reactivity and control rod worth is performed by three dimensional continues energy MCNP-4C code with neutron cross section data from the ENDF/B-VI evaluation. The neutron beam which is developed for medical purpose is generated from the reactor core by means of U-235 fission. The neutrons leaking through the cavity of HC in Be-9 reflector is guided through a tube made of stainless steel to patient position. The HC has two wheels. The first wheel is small and is used as a gate. The second is large and have three positions one to close the gate, the second to open the gate while the third for loading collimator. The collimator consists of the moderators and filters to optimize the neutron beam which is installed in the loading position. The HC VI is extended to the room constructed to allow space for other horizontal channels users. materials are used to optimize the neutron beam which was selected depending on neutron beam properties related to core loading and control rod position. The results of the development study show that the required values for the neutron beam characteristic can be nearly reached. The different comparisons of the calculations performed using MCNP-4C code with the requirements values of characteristics neutron beam show that the result values of MCNP-4C code model are reliable. (author)

  19. Neutron flux parameters for k{sub 0}-NAA method at the Malaysian nuclear agency research reactor after core reconfiguration

    Energy Technology Data Exchange (ETDEWEB)

    Yavar, A.R. [School of Applied Physics, Faculty of Science and Technology, University Kebangsaan Malaysia (UKM), Bangi, Selangor 43600 (Malaysia); Sarmani, S. [School of Chemical Sciences and Food Technology, Faculty of Science and Technology, University Kebangsaan Malaysia (UKM), Bangi, Selangor 43600 (Malaysia); Wood, A.K. [Analytical Chemistry Application Group, Industrial Technology Division, Malaysian Nuclear Agency (MNA), Bangi, Kajang, Selangor 43000 (Malaysia); Fadzil, S.M. [School of Applied Physics, Faculty of Science and Technology, University Kebangsaan Malaysia (UKM), Bangi, Selangor 43600 (Malaysia); Masood, Z. [Analytical Chemistry Application Group, Industrial Technology Division, Malaysian Nuclear Agency (MNA), Bangi, Kajang, Selangor 43000 (Malaysia); Khoo, K.S., E-mail: khoo@ukm.m [School of Applied Physics, Faculty of Science and Technology, University Kebangsaan Malaysia (UKM), Bangi, Selangor 43600 (Malaysia)

    2011-02-15

    The Malaysian Nuclear Agency (MNA) research reactor, commissioned in 1982, is a TRIGA Mark II swimming pool type reactor. When the core configuration changed in June 2009, it became essential to re-determine such neutron flux parameters as thermal to epithermal neutron flux ratio (f), epithermal neutron flux shape factor ({alpha}), thermal neutron flux ({phi}{sub th}) and epithermal neutron flux ({phi}{sub epi}) in the irradiation positions of MNA research reactor in order to guarantee accuracy in the application of k{sub 0}-neutron activation analysis (k{sub 0}-NAA).The f and {alpha} were determined using the bare bi-isotopic monitor and bare triple monitor methods, respectively; Au and Zr monitors were utilized in present study. The results for four irradiation positions are presented and discussed in the present work. The calculated values of f and {alpha} ranged from 33.49 to 47.33 and -0.07 to -0.14, respectively. The {phi}{sub th} and the {phi}{sub epi} were measured as 2.03 x 10{sup 12} (cm{sup -2} s{sup -1}) and 6.05 x 10{sup 10} (cm{sup -2} s{sup -1}) respectively. These results were compared to those of previous studies at this reactor as well as to those of reactors in other countries. The results indicate a good conformity with other findings.

  20. Neutron activation determination of iridium, gold, platinum, and silver in geologic samples

    International Nuclear Information System (INIS)

    Millard, H.T.

    1986-01-01

    Low-level methods for the determination of iridium and other noble metals have been important in recent years due to interest in locating abundance anomalies associated with the Cretaceous/Tertiary (K/T) boundary. Typical iridium anomalies are in the range of 1 to 100 ppb. Thus methods with detection limits near 0.1 ppb should be adequate to detect K/T boundary anomalies. Radiochemical neutron activation analysis methods continue to be required although instrumental neutron activation analysis techniques employing elaborate gamma-counters are under development. In the procedure employed in this study samples irradiated in the epithermal neutron facility of the U.S. Geological Survey TRIGA Reactor are treated with a mini-fire assay technique. The iridium, gold, and silver are collected in a 1-gram metallic lead button. Primary contaminants at this stage are arsenic and antimony. These can be removed by heating the button with a mixture of sodium peroxide and sodium hydroxide. The resulting 0.2-gram lead bead is counted in a Compton suppression spectrometer. Carrier yields are determined by reirradiation of the lead beads. This procedure has been applied to the U.S.G.S. Standard Rock PCC-1. and samples from K/T boundary sites in the Western Interior of North America. (author)

  1. A CONCEPTUAL DESIGN OF NEUTRON COLLIMATOR IN THE THERMAL COLUMN OF KARTINI RESEARCH REACTOR FOR IN VITRO AND IN VIVO TEST OF BORON NEUTRON CAPTURE THERAPY

    Directory of Open Access Journals (Sweden)

    Nina Fauziah

    2015-03-01

    Full Text Available Studies were carried out to design a collimator which results in epithermal neutron beam for IN VITRO and IN VIVO of Boron Neutron Capture Therapy (BNCT at the Kartini research reactor by means of Monte Carlo N-Particle (MCNP codes. Reactor within 100 kW of thermal power was used as the neutron source. The design criteria were based on recommendation from the International Atomic Energy Agency (IAEA. All materials used were varied in size, according to the value of mean free path for each material. MCNP simulations indicated that by using 5 cm thick of Ni as collimator wall, 60 cm thick of Al as moderator, 15 cm thick of 60Ni as filter, 2 cm thick of Bi as γ-ray shielding, 3 cm thick of 6Li2CO3-polyethylene as beam delimiter, with 1 to 5 cm varied aperture size, epithermal neutron beam with maximum flux of 7.65 x 108 n.cm-2.s-1 could be produced. The beam has minimum fast neutron and γ-ray components of, respectively, 1.76 x 10-13 Gy.cm2.n-1 and 1.32 x 10-13 Gy.cm2.n-1, minimum thermal neutron per epithermal neutron ratio of 0.008, and maximum directionality of 0.73. It did not fully pass the IAEA’s criteria, since the epithermal neutron flux was below the recommended value, 1.0 x 109 n.cm-2.s-1. Nonetheless, it was still usable with epithermal neutron flux exceeding 5.0 x 108 n.cm-2.s-1. When it was assumed that the graphite inside the thermal column was not discharged but only the part which was going to be replaced by the collimator, the performance of the collimator became better within the positive effect from the surrounding graphite that the beam resulted passed all criteria with epithermal neutron flux up to 1.68 x 109 n.cm-2.s-1. Keywords: design, collimator, epithermal neutron beam, BNCT, MCNP, criteria   Telah dilakukan penelitian tentang desain kolimator yang menghasilkan radiasi netron epitermal untuk uji in vitro dan in vivo pada Boron Neutron Capture Therapy (BNCT di Reaktor Riset Kartini dengan menggunakan program Monte

  2. Development of a new electronic neutron imaging system

    CERN Document Server

    Brenizer, J S; Gibbs, K M; Mengers, P; Stebbings, C T; Polansky, D; Rogerson, D J

    1999-01-01

    An electronic neutron imaging camera system was developed for use with thermal, epithermal, and fast neutrons in applications that include nondestructive inspection of explosives, corrosion, turbine blades, electronics, low Z components, etc. The neutron images are expected to provide information to supplement that available from X-ray tests. The primary camera image area was a 30x30 cm field-of-view with a spatial resolution approaching 1.6 line pairs/mm (lp/mm). The camera had a remotely changeable second lens to limit the field-of-view to 7.6x7.6 cm for high spatial resolution (at least 4 lp/mm) thermal neutron imaging, but neutron and light scatter will limit resolution for fast neutrons to about 0.5 lp/mm. Remote focus capability enhanced camera set-up for optimum operation. The 75 dB dynamic range camera system included sup 6 Li-based screens for imaging of thermal and epithermal neutrons and ZnS(Ag)-based screens for fast neutron imaging. The fast optics was input to a Super S-25 Gen II image intensifi...

  3. Experimental characterization of semiconductor-based thermal neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bedogni, R., E-mail: roberto.bedogni@lnf.infn.it [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); Bortot, D.; Pola, A.; Introini, M.V.; Lorenzoli, M. [Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano (Italy); INFN—Milano, Via Celoria 16, 20133 Milano (Italy); Gómez-Ros, J.M. [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); CIEMAT, Av. Complutense 40, 28040 Madrid (Spain); Sacco, D. [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); INAIL—DIT, Via di Fontana Candida 1, 00040 Monteporzio Catone (Italy); Esposito, A.; Gentile, A.; Buonomo, B. [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); Palomba, M.; Grossi, A. [ENEA Triga RC-1C.R. Casaccia, via Anguillarese 301, 00060 S. Maria di Galeria, Roma (Italy)

    2015-04-21

    In the framework of NESCOFI@BTF and NEURAPID projects, active thermal neutron detectors were manufactured by depositing appropriate thickness of {sup 6}LiF on commercially available windowless p–i–n diodes. Detectors with different radiator thickness, ranging from 5 to 62 μm, were manufactured by evaporation-based deposition technique and exposed to known values of thermal neutron fluence in two thermal neutron facilities exhibiting different irradiation geometries. The following properties of the detector response were investigated and presented in this work: thickness dependence, impact of parasitic effects (photons and epithermal neutrons), linearity, isotropy, and radiation damage following exposure to large fluence (in the order of 10{sup 12} cm{sup −2})

  4. A development and integration of the concentration database for relative method, k0 method and absolute method in instrumental neutron activation analysis using Microsoft Access

    International Nuclear Information System (INIS)

    Hoh Siew Sin

    2012-01-01

    Instrumental Neutron Activation Analysis (INAA) is offen used to determine and calculate the concentration of an element in the sample by the National University of Malaysia, especially students of Nuclear Science Program. The lack of a database service leads consumers to take longer time to calculate the concentration of an element in the sample. This is because we are more dependent on software that is developed by foreign researchers which are costly. To overcome this problem, a study has been carried out to build an INAA database software. The objective of this study is to build a database software that help the users of INAA in Relative Method and Absolute Method for calculating the element concentration in the sample using Microsoft Excel 2010 and Microsoft Access 2010. The study also integrates k 0 data, k 0 Concent and k 0 -Westcott to execute and complete the system. After the integration, a study was conducted to test the effectiveness of the database software by comparing the concentrations between the experiments and in the database. Triple Bare Monitor Zr-Au and Cr-Mo-Au were used in Abs-INAA as monitor to determine the thermal to epithermal neutron flux ratio (f). Calculations involved in determining the concentration are the net peak area (N p ), the measurement time (t m ), the irradiation time (t irr ), k-factor (k), thermal to epithermal neutron flux ratio (f), the parameters of the neutron flux distribution epithermal (α) and detection efficiency (ε p ). For Com-INAA databases, reference material IAEA-375 Soil was used to calculate the concentration of elements in the sample. CRM, SRM are also used in this database. After the INAA database integration, a verification process was to examine the effectiveness of the Abs-INAA was carried out by comparing the sample concentration between the in database and the experiment. The result of the experimental concentration value of INAA database software performed with high accuracy and precision. ICC

  5. The neutron porosity tool

    International Nuclear Information System (INIS)

    Oelgaard, P.L.

    1988-01-01

    The report contains a review of available information on neutron porosity tools with the emphasis on dual thermal-neutron-detector porosity tools and epithermal-neutron-detector porosity tools. The general principle of such tools is discussed and theoretical models are very briefly reviewed. Available data on tool designs are summarized with special regard to the source-detector distance. Tool operational data, porosity determination and correction of measurements are briefly discussed. (author) 15 refs

  6. Development of the JAERI computational dosimetry system (JCDS) for boron neutron capture therapy. Cooperative research

    CERN Document Server

    Kumada, H; Matsumura, A; Nakagawa, Y; Nose, T; Torii, Y; Uchiyama, J; Yamamoto, K; Yamamoto, T

    2003-01-01

    The Neutron Beam Facility at JRR-4 enables us to carry out boron neutron capture therapy with epithermal neutron beam. In order to make treatment plans for performing the epithermal neutron beam BNCT, it is necessary to estimate radiation doses in a patient's head in advance. The JAERI Computational Dosimetry System (JCDS), which can estimate distributions of radiation doses in a patient's head by simulating in order to support the treatment planning for epithermal neutron beam BNCT, was developed. JCDS is a software that creates a 3-dimentional head model of a patient by using CT and MRI images, and that generates a input data file automatically for calculation of neutron flux and gamma-ray dose distributions in the brain with the Monte Carlo code MCNP, and that displays these dose distributions on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By using CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is...

  7. Neutron flux measurements in PUSPATI Triga Reactor

    International Nuclear Information System (INIS)

    Gui Ah Auu; Mohamad Amin Sharifuldin Salleh; Mohamad Ali Sufi.

    1983-01-01

    Neutron flux measurement in the PUSPATI TRIGA Reactor (PTR) was initiated after its commissioning on 28 June 1982. Initial measured thermal neutron flux at the bottom of the rotary specimen rack (rotating) and in-core pneumatic terminus were 3.81E+11 n/cm 2 sec and 1.10E+12n/cm 2 sec respectively at 100KW. Work to complete the neutron flux data are still going on. The cadmium ratio, thermal and epithermal neutron flux are measured in the reactor core, rotary specimen rack, in-core pneumatic terminus and thermal column. Bare and Cadmium covered gold foils and wires are used for the above measurement. The activities of the irradiated gold foils and wires are determined using Ge(Li) and hyperpure germinium detectors. (author)

  8. Neutronic characterization of cylindrical core of minor excess reactivity in the nuclear reactor IPEN/MB-01 from the measure of neutron flux distribution and its reactivity ratio

    Energy Technology Data Exchange (ETDEWEB)

    Bitelli, Ulysses d' Utra; Aredes, Vitor O.G.; Mura, Luiz E.C.; Santos, Diogo F. dos; Silva, Alexandre P. da, E-mail: ubitelli@ipen.br, E-mail: vitoraredes@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    When compared to a rectangular parallelepiped configuration the cylindrical configuration of a nuclear reactor core has a better neutron economy because in this configuration the probability of the neutron leakage is smaller, causing an increase in overall reactivity in the system to the same amount of fuel used. In this work we obtained a critical cylindrical configuration with the control rods 89.50% withdraw from the active region of the IPEN/MB-01 core. This is the cylindrical configuration minimum possible excess of reactivity. Thus we obtained a cylindrical configuration with a diameter of only 28 fuel rods with lowest possible excess of reactivity. For this purpose, 112 peripheral fuel rods are removed from standard reactor core (rectangular parallelepiped of 28x28 fuel rods). In this configuration the excesses of reactivity is approximated 279 pcm. From there, we characterize the neutron field by measuring the spatial distribution of the thermal and epithermal neutron flux for the reactor operating power of 83 watts measured by neutron noise analysis technique and 92.08± 0.07 watts measured by activation technique [10]. The values of thermal and epithermal neutron flux in different directions, axial, radial north-south and radial east-west, are obtained in the asymptotic region of the reactor core, away from the disturbances caused by the reflector and control bar, by irradiating thin gold foils infinitely diluted (1% Au - 99% Al) with and without (bare) cadmium cover. In addition to the distribution of neutron flux, the moderator temperature coefficient, the void coefficient, calibration of the control rods were measured. (author)

  9. Treatment planning figures of merit in thermal and epithermal boron capture therapy of brain tumours

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, S.A.; Mathur, J.N. (Wollongong Univ., NSW (Australia)); Allen, B.J. (Ansto PMB 1 Menai, NSW (Australia). Biomedicine and Health)

    1994-05-01

    The boron neutron capture therapy (BNCT) figures of merit of advantage depth, therapeutic depth, modified advantage depth and maximum therapeutic depth have been studied as functions of [sup 10]B tumour to blood ratios and absolute levels. These relationships were examined using the Monte Carlo neutron photon transport code, MCNP, with an ideal 18.4 cm diameter neutron beam incident laterally upon an ellipsoidal neutron photon brain-equivalent model. Mono-energetic beams of 0.025 eV (thermal) and 35 eV (epithermal) were simulated. Increasing the tumour to blood [sup 10]B ratio predictably increases all figures of merit. [sup 10]B concentration was also shown to have a strong bearing on the figures of merit when low levels were present in the system. This is the result of a non-[sup 10]B dependent background dose. At higher levels however, the concentration of [sup 10]B has a diminishing influence. For boron sulphydryl (BSH), little advantage is gained by extending the blood [sup 10]B level beyond 30 ppm, whilst for D, L,-p-boronophenylalanine (BPA) this limit is 10 ppm. Applying the epithermal beam under identical conditions, the therapeutic depth reaches the brain mid-line with a tumour to blood [sup 10]B ratio of only 5.7 for BPA. For BSH, the maximum therapeutic depth reaches the brain mid-line with a tumour to blood ratio of only 1.9 with 30 ppm in the blood. Human data for these compounds are very close to these requirements. (author).

  10. The influence of rhodium burn-up on the sensitivity of rhodium self-powered neutron detectors

    International Nuclear Information System (INIS)

    Erben, O.

    1980-01-01

    Depression and self-shielding coefficients are presented for thermal and epithermal neutron flux densities. Functions are shown describing the distribution of beta particle sources on the emitter cross section for 0 to 50% rhodium burnup. The values are calculated of detector sensitivity to thermal and epithermal neutron flux densities for the said burnup for main types of rhodium SPN detectors made by SODERN. (J.B.)

  11. Neutron Optics: Towards Applications for Hot Neutrons

    International Nuclear Information System (INIS)

    Schanzer, C; Schneider, M; Böni, P

    2016-01-01

    Supermirrors with large critical angles of reflection, i.e. large index m are an essential ingredient to transport, focus and polarise neutrons over a wide range of energy. Here we summarise the recent developments of supermirror with very large critical angles of reflection and high reflectivity that were conducted at SwissNeutronics as well as their implementation in devices. Approaching critical angles m = 8 times the critical angle of natural nickel makes new applications possible and extends the use of reflection optics towards the regime of hot and epithermal neutrons. Based on comparisons of simulations with experiment we demonstrate future possibilities of applications of large-m supermirrors towards devices for neutrons with short wavelength. (paper)

  12. Utilizing horizontal reactors channels for neutron therapy

    International Nuclear Information System (INIS)

    Stankovsky, E.Yu.; Kurachenko, Yu.A.

    2000-01-01

    Two experimental heterogeneous reactors have been considered. The reactors may be applied in neutron capture therapy and in a conventional manner. The channel out of the core serves as the neutron source. At each of these facilities, both fast and epithermal neutron fluxes for BNCT research, human clinical trials, and characterized common computational techniques have been evaluated. (authors)

  13. Neutron activation analysis for environmental trace element research determination of elemental composition of sediments in the Sea of Galillee, Israel

    Energy Technology Data Exchange (ETDEWEB)

    Lavi, N; Ne` eman, E; Brenner, S; Butenko, V [Tel Aviv Univ. (Israel). Medical School

    1996-12-01

    The aims of this work were to: a) demonstrate the effectiveness of instrumental neutron activation analysis for determining the background concentrations of trace elements in the sediments collected from the Sea of Gallile. b) determine the advantage factors for epithermal neutron irradiation. c) determine the contribution of silicon to the total {sup 28}Al activity by the {sup 28}Si(n,p){sup 28}Al reaction. c) check the validity of the method by determining the elemental content of U.S. NBS Standard Reference Material SRM-1633a (fly ash). d) calculate the average enrichment factors for the elements in sediments . e) determine the concentrations of the artificial radionuclides {sup 134}Cs, {sup 137}Cs and the naturally occurring radionuclides {sup 40}K, {sup 226}Ra and {sup 232}Th (authors).

  14. Simultaneous thermal neutron decay time and porosity logging system

    International Nuclear Information System (INIS)

    Shultz, W.E.

    1980-01-01

    A method for simultaneously determining the porosity and thermal neutron capture cross-section of earth formations in the vicinity of a well borehole is claimed. It comprises the following steps: passing a well tool into a cased well borehole. The tool has a pulsed source of fast neutrons, a combination fast neutron and gamma ray detector and an epithermal neutron detector; repetitively irradiating the earth formations in the vicinity of the borehole with bursts of fast neutrons; detecting the fast neutron and epithermal neutron populations in the borehole (during the neutron bursts) and generating first and second measurement signals; detecting for second and third time intervals during the time between the neutron bursts, the gamma radiation present in the borehole due to the capture of thermalized neutrons by the nuclei of elements comprising the earth formations and generating third and fourth measurement signals; and combining the first and second measurement signals according to a predetermined relationship to derive an indication of the porosity of the earth formations and combining the third and fourth measurement signals to derive an indication of the thermal neutron capture cross-section of the earth formations

  15. Notes on neutron flux measurement; Notas sobre medida de flujos neutronicos

    Energy Technology Data Exchange (ETDEWEB)

    Alcala Ruiz, F

    1984-07-01

    The main purpose of this work is to get an useful guide to carry out topical neutron flux measurements. Although the foil activation technique is used in the majority of the cases, other techniques, such as those based on fission chambers and self-powered neutron detectors, are also shown. Special interest is given to the description and application of corrections on the measurement of relative and absolute induced activities by several types of detectors (scintillators, G-M and gas proportional counters). The thermal arid epithermal neutron fluxes, as determined in this work, are conventional or effective (West cots fluxes), which are extensively used by the reactor experimentalists; however, we also give some expressions where they are related to the integrated neutron fluxes, which are used in neutron calculations. (Author) 16 refs.

  16. Neutronic characterization of cylindrical core of minor excess reactivity in the nuclear reactor IPEN/MB-01 from the measure of spatial and energetic distribution of neutron flux distribution; Caracterizacao do nucleo cilindrico de menor excesso de reatividade do reator IPEN/MB-01, pela medida da distribuicao espacial e energetica do fluxo de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Aredes, Vitor Ottoni Garcia

    2014-07-01

    In this work was conducted the mapping of the thermal and epithermal neutrons flux and the energy spectrum of the neutrons in the reactor core IPEN/MB-01 for a cylindrical core configuration with minor excess reactivity, which is 28 x 28 fuel rods arranged in north-south and east-west directions. The calibration of control rods for this configuration determined their excess reactivity. The lower excess reactivity in the core decreased neutron flux disturbance caused by the neutron absorbing rods , given that the nuclear reactor was operated with the rods almost completely removed . Was used the 'Activation Analysis Technique' with the thin foil activation detectors ( infinitely diluted and hyper-pure), of different materials that work in different energy ranges, to calculate the saturation activity, used for determining the neutron flux and in the SANDBP code as input for the calculation of the neutrons energy spectrum. To discriminate thermal and epithermal flux , was used the 'Cadmium RatioTechnique' . The activation detectors were distributed in a total of 140 radial and axial positions in the reactor core and 16 irradiation, with bare and covered with cadmium activation foils. A model of this configuration was simulated by MCNP-5 code to determine the cadmium correction factor and comparison of the results obtained experimentally. The cylindrical configuration desired, with 17% less fuel than the standard rectangular configuration (28 x 26 fuel rods), reached criticality with the control rods approximately 90% removed, which decreased considerably the disturbance in neutron flux. Given the highest power density of the 28 x 28 cylindrical core, the neutron flux increased by over 50% in the central regions of the core compared to the values of the 28 x 26 standard rectangular core. (author)

  17. Correction Factor Analysis Of Foil Activation And The Effect Of Neglecting The Correction On Neutron Flux And Spectrum Measurement; ANALISIS FAKTOR KOREKSI KEPING AKTIVASI DAN PENGARUH PENGABAIANNYA PADA PENGUKURAN FLUKS DAN SPEKTRUM NEUTRON

    Energy Technology Data Exchange (ETDEWEB)

    Radiyanti, Ita Budi; Hamzah, Amir; Pinem, Surian [Multipurpose Reactor Centre Indonesia, Serpong, (Indonesia)

    1996-04-15

    Foil activation method is commonly used in flux and neutron spectrum measurement in nuclear reactor and other research. The effect of the thickness, type of foil material and neutron spectrum shape on the self shielding correction and activities correction on the edges of the foil have been analyzed. Also the effect of neglecting those correction factors on neutron flux and spectrum measurement were analyzed. The calculation of the correction factor has been done by using the program which had been verified for several foils. The foils used are Au, In. Cu, Co and Dy of 0.00254 cm -0.127 cm thickness and 1.27 cm diameter. The result showed that the correction factor foils were not similar due to the variation of activation cross section and neutron spectrum shape. For the neutron spectrum in RS-2 multi purpose reactor GAS using foils of 0.00254 cm thick. The effect of neglecting correction factor on thermal flux measurement for Au, In, Co and Cu were less than -6%, for Dy was about -25%. On epithermal flux measurement for Au and In were about -60%, Co and Dy was -12% and -6%, for Cu less than -2%. The effect of neglecting correction factor on spectrum measurement was the change on the neutron flux density values along neutron energy region.

  18. Neutron activation analysis and atomic absorption spectrophotometry for the analysis of fresh, pasteurised and powder milk

    International Nuclear Information System (INIS)

    Wasim, M.; Rehman, S.; Arif, M.; Fatima, I.; Zaidi, J.H.

    2012-01-01

    This study shows the application of semi-absolute k 0 instrumental neutron activation analysis (k 0 -INAA), epithermal neutron activation analysis (ENAA) and atomic absorption spectrophotometry (AAS) for the determination of 21 elements (Br, Ca, Cl, Co, Cr, Cs, Cu, Fe, Hf, I, K, Mg, Mn, Na, Ni, P, Pb, Rb, Sc Sr, and Zn) in different types of milk samples. The ENAA was required for the determination of iodine, AAS for Cu, Ni and Pb and the rest of the elements were measured by k 0 -INAA. Thirteen elements (Br, Ca, Cl, Cs, Cu, Fe, K, Mg, Na, P, Rb, Sr and Zn) were identified in all milk samples. Ni was detected in eleven and Pb in two samples. Concentrations of most of the elements were within the ranges of the world reported data. The data was further explored by principal component analysis to find relationships between samples and elements. (orig.)

  19. Monte Carlo based dosimetry and treatment planning for neutron capture therapy of brain tumors

    International Nuclear Information System (INIS)

    Zamenhof, R.G.; Clement, S.D.; Harling, O.K.; Brenner, J.F.; Wazer, D.E.; Madoc-Jones, H.; Yanch, J.C.

    1990-01-01

    Monte Carlo based dosimetry and computer-aided treatment planning for neutron capture therapy have been developed to provide the necessary link between physical dosimetric measurements performed on the MITR-II epithermal-neutron beams and the need of the radiation oncologist to synthesize large amounts of dosimetric data into a clinically meaningful treatment plan for each individual patient. Monte Carlo simulation has been employed to characterize the spatial dose distributions within a skull/brain model irradiated by an epithermal-neutron beam designed for neutron capture therapy applications. The geometry and elemental composition employed for the mathematical skull/brain model and the neutron and photon fluence-to-dose conversion formalism are presented. A treatment planning program, NCTPLAN, developed specifically for neutron capture therapy, is described. Examples are presented illustrating both one and two-dimensional dose distributions obtainable within the brain with an experimental epithermal-neutron beam, together with beam quality and treatment plan efficacy criteria which have been formulated for neutron capture therapy. The incorporation of three-dimensional computed tomographic image data into the treatment planning procedure is illustrated. The experimental epithermal-neutron beam has a maximum usable circular diameter of 20 cm, and with 30 ppm of B-10 in tumor and 3 ppm of B-10 in blood, it produces a beam-axis advantage depth of 7.4 cm, a beam-axis advantage ratio of 1.83, a global advantage ratio of 1.70, and an advantage depth RBE-dose rate to tumor of 20.6 RBE-cGy/min (cJ/kg-min). These characteristics make this beam well suited for clinical applications, enabling an RBE-dose of 2,000 RBE-cGy/min (cJ/kg-min) to be delivered to tumor at brain midline in six fractions with a treatment time of approximately 16 minutes per fraction

  20. Study of the RP-10 reactor neutron beam applied to the neutron radiography

    International Nuclear Information System (INIS)

    Zegarra, Manuel; Lopez, Alcides

    2013-01-01

    We have studied the RP-10 reactor radial neutron beam No. 3, which is used for neutron radiographies, by comparing radiograph's with and without the inner duct, and neutron flux determination with in flakes along the external duct, being the presence of photons creating signals at comparable levels of neutron effects, which reduce the quality of the analysis, values around 10 6 and 10 4 n/cm 2 s for thermal and epithermal flux were obtained respectively. It is recommended evaluate the design of the internal duct which presents strong photon emission. (authors).

  1. Calculations of the thermal and fast neutron fluxes in the Syrian miniature neutron source reactor using the MCNP-4C code.

    Science.gov (United States)

    Khattab, K; Sulieman, I

    2009-04-01

    The MCNP-4C code, based on the probabilistic approach, was used to model the 3D configuration of the core of the Syrian miniature neutron source reactor (MNSR). The continuous energy neutron cross sections from the ENDF/B-VI library were used to calculate the thermal and fast neutron fluxes in the inner and outer irradiation sites of MNSR. The thermal fluxes in the MNSR inner irradiation sites were also measured experimentally by the multiple foil activation method ((197)Au (n, gamma) (198)Au and (59)Co (n, gamma) (60)Co). The foils were irradiated simultaneously in each of the five MNSR inner irradiation sites to measure the thermal neutron flux and the epithermal index in each site. The calculated and measured results agree well.

  2. An Emergency Dosimeter for Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Braun, J; Nilsson, R

    1960-05-15

    A neutron dosimeter suitable for single emergency exposures is described. The dosimeter is furnished with detectors for thermal, epi-thermal and fast neutrons. This means that three of the constants by which the spectrum of the incident neutron flux is approximated, can be determined. The dose calculated from these approximated spectra is compared to the dose from spectra obtained in different standard spectra of types which may be expected in a radiation accident.

  3. Preparation of the in-house neutron detectors and the software needed to process experimental data

    International Nuclear Information System (INIS)

    Haddad, Kh.; Haj-Hassan, H.; Helal, W.

    2007-04-01

    In - house neutron activation detectors were prepared in this work using pure commercial gold. The neutron self-shielding factors in the foils for both thermal and epithermal neutrons have been determined experimentally. The work shows good results repeatability and good agreement with certified activation monitors. the software KHW for neutron flux measurements using local and standards gold foils was designed and performed locally. it deals as well with irradiated uranium spectrums to calculate some important fission product ratios for neutron flux measurement. Some experiments were performed to investigate the possibility of using uranium, produced in the pilot plant, as fission neutron detector. The results shows the possibility of using fission product ratios to determine the cooling time of the samples. It shows also the possibility of using fission and activation product ratios as an indicators of neutron fluences ratios.(author)

  4. Studies on application of radiation and radioisotopes -Studies on application of neutron activation analysis-

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Yong Sam; Jung, Yung Joo; Jung, Eui Sik; Lee, Sang Mee [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Kim, Nak Bae [Korea Institute of Geology, Mining and Materials, Taejon (Korea, Republic of)

    1995-07-01

    To apply Neutron activation analysis to routine analysis of environmental samples utilizing the research reactor (TRIGA MK-III), improving effects of analytical sensitivity have been investigated using both of thermal and epithermal neutron irradiating technique. Identification and development of analytical procedure was carried out using three kinds of standard reference materials (urban particulate matter, coal fly ash, soil). In addition, the confidence of this method was established by participation in collaborative research for the training and apply of international credit of analytical procedure. Practical studies on air dust samples have also been carried out regionally and seasonally. For the investigation on emission source of special element, enrichment factor was calculated in urban and rural area. Besides, a suitable process of biological sample (pine needle) analyses has been established by carrying out identification of uncertainty using standard reference material. The concentration of elements in practical samples were also determined regionally and seasonally. 14 figs, 26 tabs, 67 refs. (Author).

  5. Studies on application of radiation and radioisotopes -Studies on application of neutron activation analysis-

    International Nuclear Information System (INIS)

    Jung, Yong Sam; Jung, Yung Joo; Jung, Eui Sik; Lee, Sang Mee; Kim, Nak Bae

    1995-07-01

    To apply Neutron activation analysis to routine analysis of environmental samples utilizing the research reactor (TRIGA MK-III), improving effects of analytical sensitivity have been investigated using both of thermal and epithermal neutron irradiating technique. Identification and development of analytical procedure was carried out using three kinds of standard reference materials (urban particulate matter, coal fly ash, soil). In addition, the confidence of this method was established by participation in collaborative research for the training and apply of international credit of analytical procedure. Practical studies on air dust samples have also been carried out regionally and seasonally. For the investigation on emission source of special element, enrichment factor was calculated in urban and rural area. Besides, a suitable process of biological sample (pine needle) analyses has been established by carrying out identification of uncertainty using standard reference material. The concentration of elements in practical samples were also determined regionally and seasonally. 14 figs, 26 tabs, 67 refs. (Author)

  6. Measurements of neutron flux in the RA reactor; Merenje karakteristika neutronskog fluksa u reaktoru RA

    Energy Technology Data Exchange (ETDEWEB)

    Raisic, N [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1961-12-15

    This report includes results of the following measurements performed at the RA reactor: thermal neutron flux in the experimental channels, epithermal and fast neutron flux, neutron flux in the biological shield, neutron flux distribution in the reactor cell.

  7. Design and simulation of an optimized e-linac based neutron source for BNCT research

    International Nuclear Information System (INIS)

    Durisi, E.; Alikaniotis, K.; Borla, O.; Bragato, F.; Costa, M.; Giannini, G.; Monti, V.; Visca, L.; Vivaldo, G.; Zanini, A.

    2015-01-01

    The paper is focused on the study of a novel photo-neutron source for BNCT preclinical research based on medical electron Linacs. Previous studies by the authors already demonstrated the possibility to obtain a mixed thermal and epithermal neutron flux of the order of 10"7 cm"−"2 s"−"1. This paper investigates possible Linac’s modifications and a new photo-converter design to rise the neutron flux above 5 10"7 cm"−"2 s"−"1, also reducing the gamma contamination. - Highlights: • Proposal of a mixed thermal and epithermal (named hyperthermal) neutron source based on medical high energy electron Linac. • Photo-neutron production via Giant Dipole Resonance on high Z materials. • MCNP4B-GN simulations to design the photo-converter geometry maximizing the hyperthermal neutron flux and minimizing the fast neutron and gamma contaminations. Hyperthermal neutron field suitable for BNCT preclinical research.

  8. Conversion ratio in epithermal PWR, in thorium and uranium cycle

    International Nuclear Information System (INIS)

    Barroso, D.E.G.

    1982-01-01

    Results obtained for the conversion ratio in PWR reactors with close lattices, operating in thorium and uranium cycles, are presented. The study of those reactors is done in an unitary fuel cell of the lattices with several ratios V sub(M)/V sub(F), considering only the equilibrium cycles and adopting a non-spatial depletion calculation model, aiming to simulate mass flux of reactor heavy elements in the reactor. The neutronic analysis and the cross sections generation are done with Hammer computer code, with one critical apreciation about the application of this code in epithermal systems and with modifications introduced in the library of basic data. (E.G.) [pt

  9. Accelerator-based epithermal neutron sources for boron neutron capture therapy of brain tumors.

    Science.gov (United States)

    Blue, Thomas E; Yanch, Jacquelyn C

    2003-01-01

    This paper reviews the development of low-energy light ion accelerator-based neutron sources (ABNSs) for the treatment of brain tumors through an intact scalp and skull using boron neutron capture therapy (BNCT). A major advantage of an ABNS for BNCT over reactor-based neutron sources is the potential for siting within a hospital. Consequently, light-ion accelerators that are injectors to larger machines in high-energy physics facilities are not considered. An ABNS for BNCT is composed of: (1) the accelerator hardware for producing a high current charged particle beam, (2) an appropriate neutron-producing target and target heat removal system (HRS), and (3) a moderator/reflector assembly to render the flux energy spectrum of neutrons produced in the target suitable for patient irradiation. As a consequence of the efforts of researchers throughout the world, progress has been made on the design, manufacture, and testing of these three major components. Although an ABNS facility has not yet been built that has optimally assembled these three components, the feasibility of clinically useful ABNSs has been clearly established. Both electrostatic and radio frequency linear accelerators of reasonable cost (approximately 1.5 M dollars) appear to be capable of producing charged particle beams, with combinations of accelerated particle energy (a few MeV) and beam currents (approximately 10 mA) that are suitable for a hospital-based ABNS for BNCT. The specific accelerator performance requirements depend upon the charged particle reaction by which neutrons are produced in the target and the clinical requirements for neutron field quality and intensity. The accelerator performance requirements are more demanding for beryllium than for lithium as a target. However, beryllium targets are more easily cooled. The accelerator performance requirements are also more demanding for greater neutron field quality and intensity. Target HRSs that are based on submerged-jet impingement and

  10. Single Crystal Filters for Neutron Spectrometry

    International Nuclear Information System (INIS)

    Habib, N.

    2008-01-01

    A study of neutron transmission properties trough a large single crystals specimens of Si, Ge, Pb, Bi and sapphire at 300 K and 80 K have been made for a wide range of neutron energies. The effectiveness of such filters is given by the ratio of the total cross-section of unwanted epithermal neutrons to that the desired thermal neutron beam and by the optimum choice of the crystal orientation, its mosaic spread, thickness and temperature.Our study indicates that sapphire is significantly more effective than the others for a wide range of neutron energies

  11. Determination of silver, gold, zinc and copper in mineral samples by various techniques of instrumental neutron activation analysis; Determinacion de plata, oro, zinc y cobre en muestras minerales mediante diversas tecnicas de analisis por activacion de neutrones instrumental

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez R, N. I.; Rios M, C.; Pinedo V, J. L. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico); Yoho, M.; Landsberger, S., E-mail: neisla126@hotmail.com [University of Texas at Austin, Nuclear Engineering Teaching Laboratory, Austin 78712, Texas (United States)

    2015-09-15

    Using the method of instrumental neutron activation analysis, mineral exploration samples were analyzed in order to determine the concentrations of silver, gold, zinc and copper; these minerals being the main products of benefit of Tizapa and Cozamin mines. Samples were subjected to various techniques, where the type of radiation and counting methods were chosen based on the specific isotopic characteristics of each element. For calibration and determination of concentrations the comparator method was used, certified standards were subjected to the same conditions of irradiation and measurement that the prospecting samples. The irradiations were performed at the research reactor TRIGA Mark II of the University of Texas at Austin. The silver concentrations were determined by Cyclical Epithermal Neutron Activation Analysis. This method in combination with the transfer pneumatic system allowed a good analytical precision and accuracy in prospecting for silver, from photo peak measurement 657.7 keV of short half-life radionuclide {sup 110}Ag. For the determination of gold and zinc, Epithermal Neutron Activation Analysis was used, the photo peaks analyzed corresponded to the energies 411.8 keV of radionuclide {sup 199}Au and 438.6 keV of metastable radionuclide {sup 69m}Zn. On the other hand, copper quantification was based on the photo peak analysis of 1039.2 keV produced by the short half-life radionuclide {sup 66}Cu, by Thermal Neutron Activation Analysis. The photo peaks measurement corresponding to gold, zinc and copper was performed using a Compton suppression system, which allowed an improvement in the signal to noise relationship, so that better detection limits and low uncertainties associated with the results were obtained. Comparing elemental concentrations the highest values in silver, zinc and copper was for samples of mine Tizapa. Regarding gold values were found in the same range for both mines. To evaluate the precision and accuracy of the methods used

  12. Neutron metrology in the HFR

    International Nuclear Information System (INIS)

    Voorbraak, W.P.; Freudenreich, W.E.; Stecher-Rasmussen, F.; Verhagen, H.W.

    1991-10-01

    Neutron fluence rate and gamma dose data are presented for the first series of experiments at the filtered HFR beam HB11 at full reactor power. Measurements were performed on two beagle dogs and one cylindrical phantom. The main results for thermal and epithermal fluence rates, physical neutron dose and gamma dose are presented in the tables 1 and 2. (author). 10 refs.; 9 figs.; 8 tabs

  13. Optimization of beam shaping assembly based on D-T neutron generator and dose evaluation for BNCT

    Science.gov (United States)

    Naeem, Hamza; Chen, Chaobin; Zheng, Huaqing; Song, Jing

    2017-04-01

    The feasibility of developing an epithermal neutron beam for a boron neutron capture therapy (BNCT) facility based on a high intensity D-T fusion neutron generator (HINEG) and using the Monte Carlo code SuperMC (Super Monte Carlo simulation program for nuclear and radiation process) is proposed in this study. The Monte Carlo code SuperMC is used to determine and optimize the final configuration of the beam shaping assembly (BSA). The optimal BSA design in a cylindrical geometry which consists of a natural uranium sphere (14 cm) as a neutron multiplier, AlF3 and TiF3 as moderators (20 cm each), Cd (1 mm) as a thermal neutron filter, Bi (5 cm) as a gamma shield, and Pb as a reflector and collimator to guide neutrons towards the exit window. The epithermal neutron beam flux of the proposed model is 5.73 × 109 n/cm2s, and other dosimetric parameters for the BNCT reported by IAEA-TECDOC-1223 have been verified. The phantom dose analysis shows that the designed BSA is accurate, efficient and suitable for BNCT applications. Thus, the Monte Carlo code SuperMC is concluded to be capable of simulating the BSA and the dose calculation for BNCT, and high epithermal flux can be achieved using proposed BSA.

  14. Enhancements and Health-Related Studies of Neutron Activation Analysis Technique

    International Nuclear Information System (INIS)

    Soliman, M.A.M.

    2012-01-01

    The work presented in this thesis covers two major points. One algorithm concerns with establishment of an accurate standardization method with multi-elemental capabilities and low workload suitable for NAA standardization at ETRR-2. The second one deals with constructing and developing an effective nondestructive technique for analysis of liquid samples based on NAA using (very) short-lived radionuclides. To achieve the first goal, attention has been directed toward implementation of the k 0 -method for calculation of the elements concentrations in the samples. The k 0 -method of NAA standardization has a considerable success as a method for accurate multi-elemental analysis with comparable low workload. The k 0 - method is based on the fact that the unknown sample is irradiated with only one standard element as comparator. To access the implementation of this method at ETRR-2, careful and complete characterization of the neutron flux parameters in the irradiation positions as well as the efficiency calibration of the γ-ray spectrometer must be carried out. The required neutron flux parameters are: the ratio of the thermal to epithermal neutron fluxes (f) and the deviation factor (α) of the epithermal neutron flux from the ideal 1/E law. The work presented in Chapter 4 shows the efficiency calibration curve of the γ ray spectrometer system which was obtained using standard radioactive point sources. Moreover, the f and α parameters were determined in some selected irradiation sites using sets of Zr-Au as neutron flux monitors. Due to different locations relative to the reactor core, the available neutron fluxes in the selected irradiation positions differ substantially, so that different irradiation demands can be satisfied. The reference materials coal NIST 1632c and IAEA-Soil 7 were analyzed for data validation and good agreement between the experimental values and the certified values was obtained. The obtained results have revealed that the k 0 -NAA

  15. Application of reactors for testing neutron-induced upsets in commercial SRAMs

    International Nuclear Information System (INIS)

    Griffin, P.J.; Luera, T.F.; Sexton, F.W.; Cooper, P.J.; Karr, S.G.; Hash, G.L.; Fuller, E.

    1997-01-01

    Reactor neutron environments can be used to test/screen the sensitivity of unhardened commercial SRAMs to low-LET neutron-induced upset. Tests indicate both thermal/epithermal (< 1 keV) and fast neutrons can cause upsets in unhardened parts. Measured upset rates in reactor environments can be used to model the upset rate for arbitrary neutron spectra

  16. Problems and prospects of neutron imaging

    International Nuclear Information System (INIS)

    Kobayashi, Hisao

    2008-01-01

    Technical problems and future prospects of neutron imaging and neutron radiography are reviewed and discussed for further development. For technical problems, neutron sources together with cold neutron, ultra-cold neutron, epithermal and fast-neutron beams, energy converters, and the intensity of neutron beam, dynamic range associated with imaging procedure, etc, are reviewed. As standardization, such indicators as beam purity, sensitivity, image quality, and beam quality are discussed and limitation of neutron radiography is also presented. As neutron imaging has developed as a nondestructive testing technique in industrial applications, further problems and prospects of quality control and qualification to perform neutron radiography, standardization and international cooperation of neutron imaging are discussed. (S. Ohno)

  17. Three new nondestructive evaluation tools based on high flux neutron sources

    International Nuclear Information System (INIS)

    Hubbard, C.R.; Raine, D.; Peascoe, R.; Wright, M.

    1997-01-01

    Nondestructive evaluation methods and systems based on specific attributes of neutron interactions with materials are being developed. The special attributes of neutrons are low attenuation in most engineering materials, strong interaction with low Z elements, and epithermal neutron absorption resonances. The three methods under development at ORNL include neutron based tomography and radiography; through thickness, nondestructive texture mapping; and internal, noninvasive temperature measurement. All three techniques require high flux sources such as the High Flux Isotope Reactor, a steady state source, or the Oak Ridge Electron Linear Accelerator, a pulsed neutron source. Neutrons are quite penetrating in most engineering materials and thus can be useful to detect internal flaws and features. Hydrogen atoms, such as in a hydrocarbon fuel, lubricant, or a metal hydride, are relatively opaque to neutron transmission and thus neutron based tomography/radiography is ideal to image their presence. Texture, the nonrandom orientation of crystalline grains within materials, can be mapped nondestructively using neutron diffraction methods. Epithermal neutron resonance absorption is being studied as a noncontacting temperature sensor. This paper highlights the underlying physics of the methods, progress in development, and the potential benefits for science and industry of the three facilities

  18. Modelisation and distribution of neutron flux in radium-beryllium source (226Ra-Be)

    Science.gov (United States)

    Didi, Abdessamad; Dadouch, Ahmed; Jai, Otman

    2017-09-01

    Using the Monte Carlo N-Particle code (MCNP-6), to analyze the thermal, epithermal and fast neutron fluxes, of 3 millicuries of radium-beryllium, for determine the qualitative and quantitative of many materials, using method of neutron activation analysis. Radium-beryllium source of neutron is established to practical work and research in nuclear field. The main objective of this work was to enable us harness the profile flux of radium-beryllium irradiation, this theoretical study permits to discuss the design of the optimal irradiation and performance for increased the facility research and education of nuclear physics.

  19. Status report on the development of a prompt fission neutron uranium borehole logging technique

    International Nuclear Information System (INIS)

    Smith, G.W.

    1977-05-01

    The prompt fission neutron (PFN) method of direct uranium measurement was studied. The PFN uranium logging technique measures the enhanced epithermal neutron population created by the prompt thermal fission of 235 U to assay uranium mineralization around a borehole. This neutron population exists for several hundred microseconds after a pulsed neutron source produces a burst of high energy (14 MeV) neutrons. A feasibility study established the basic relationship between the uranium concentration and the enhanced epithermal neutron count, and defined the major measurement perturbing factors. Following the feasibility study, development of a PFN prototype field probe was undertaken. A laboratory type neutron generator, the Controlatron, was modified for use in the probe. Field evaluation of the prototype system began in January 1976. Comparisons of neutron logs and natural gamma logs taken during this evaluation period clearly define many disequilibrium conditions as verified by ore grade estimates from core samples. The feasibility of the PFN logging technique to detect uranium in-situ has now been demonstrated

  20. Assessment of a silicon detector for pulsed neutron scattering experiments

    International Nuclear Information System (INIS)

    Tardocchi, M.; Arnaboldi, C.; Gorini, G.; Imberti, S.; Pessina, G.; Previtali, E.; Andreani, C.; Pietropaolo, A.; Senesi, R.

    2004-01-01

    Resonance detectors (RD) are being developed for neutron spectroscopy in the epithermal energy region at spallation neutron sources. Different choices of converter foils and gamma spectrometers are being compared as part of an optimization and selection process within the TECHNI project. This paper reports on the design of a silicon detector system and some preliminary tests on the VESUVIO spectrometer. The detector has a good efficiency in the X-ray energy range, where two intense photon peaks (at 12 and 48 keV) are expected to be emitted following neutron capture in a uranium converter foil. The detector energy resolution has been improved by nitrogen vapor cooling of the silicon chip and by careful design of the preamplifier electronics. Neutron time of flight spectra have been measured on VESUVIO when the converter foil is placed in the neutron beam. In that case, the detector response is dominated by a continuum due to Compton detection of gammas of higher energy. These results provide a basis for a critical assessment of the applicability of silicon detectors for RD measurements of epithermal neutrons

  1. Mock-up experiment at Birmingham University for BNCT project of Osaka University – Neutron flux measurement with gold foil

    International Nuclear Information System (INIS)

    Tamaki, S.; Sakai, M.; Yoshihashi, S.; Manabe, M.; Zushi, N.; Murata, I.; Hoashi, E.; Kato, I.; Kuri, S.; Oshiro, S.; Nagasaki, M.; Horiike, H.

    2015-01-01

    Mock-up experiment for development of accelerator based neutron source for Osaka University BNCT project was carried out at Birmingham University, UK. In this paper, spatial distribution of neutron flux intensity was evaluated by foil activation method. Validity of the design code system was confirmed by comparing measured gold foil activities with calculations. As a result, it was found that the epi-thermal neutron beam was well collimated by our neutron moderator assembly. Also, the design accuracy was evaluated to have less than 20% error. - Highlights: • Accelerator based neutron source for BNCT is being developed in Osaka University. • Mock-up experiment was carried out at Birmingham University, UK. • Neutronics performance of our assembly was evaluated from gold foil activation. • Gold foil activation was determined by using HPGe detectors. • Validity of the neutronics design code system was confirmed.

  2. Calibration of SPND/Rhodium device for mapping the neutron fluence in the IEA-R1 reactor by means of the activation foil method; Calibracao de um dispositivo de mapeamento de fluxo de neutrons - SNPD/Rodio no reator IEA-R1, por meio do metodo de ativacao de folhas

    Energy Technology Data Exchange (ETDEWEB)

    Ricci Filho, Walter; Dias, Mauro S.; Tondin, Julio B.M.; Koskinas, Marina F. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2002-07-01

    The IEA-R1 reactor has undergone a modernization to increase its operating power to 5 MW, in order to allow a more efficient production of radioisotopes. The objective of this work is to provide the reactor with flux monitoring device using a rhodium Self-Powered Neutron Detector (SPND). The work presents the results obtained with Rhodium-SPND in several irradiation positions inside the reactor core. A calibration procedure has been performed by means of {sup 197} Au activation foils, with and without cadmium cover, in order do measure the thermal and epithermal neutron fluxes. (author)

  3. New scientific horizons with pulsed spallation neutron sources

    International Nuclear Information System (INIS)

    Carlile, C.J.; Finney, J.L.

    1991-01-01

    Pulsed spallation sources are not just another way of producing neutrons: the time structure of the neutron pulse has consequences which allow new scientific areas to be investigated and traditional areas to be explored afresh. In addition to the high epithermal neutron component traditionally associated with pulsed sources the recent development of cold neutron techniques at ISIS illustrates that very high energy and momentum resolutions can be achieved on pulsed sources over a surprisingly wide range. (orig.)

  4. Nuclear polarization and neutrons

    International Nuclear Information System (INIS)

    Glaettli, H.

    1985-01-01

    Different possibilities for the use of polarized nuclei in thermal neutron scattering on condensed matter are reviewed. Highly polarized nuclei are the starting point for studying dipolar magnetic order. Systematic measurement of spin-dependent scattering lengths is possible on samples with polarized nuclei. Highly polarized hydrogen should help to unravel complicated structures in chemistry and biology. The use of polarized proton targets as an energy-independent neutron polarizer in the thermal and epithermal region should be considered afresh. (author)

  5. Level gauge using neutron radiation

    International Nuclear Information System (INIS)

    Mathew, P.J.

    1985-01-01

    Apparatus for determining the level of a solid or liquid material in a container comprises: a vertical guide within or alongside the container; a sensor positioned within the guide; means for moving the sensor along the guide; and means for monitoring the position of the sensor. The sensor comprises a source of fast neutrons, a detector for thermal neutrons, and a body of a neutron moderating material in close proximity to the detector. Thermal neutrons produced by fast neutron irradiation of the solid or liquid material, or thermal neutrons produced by irradiation of the neutron-moderating material by fast or epithermal neutrons reflected by the solid or liquid material, are detected when the sensor is positioned at or below the level of the material in the container

  6. Monte Carlo calculation for the development of a BNCT neutron source (1eV-10KeV) using MCNP code.

    Science.gov (United States)

    El Moussaoui, F; El Bardouni, T; Azahra, M; Kamili, A; Boukhal, H

    2008-09-01

    Different materials have been studied in order to produce the epithermal neutron beam between 1eV and 10KeV, which are extensively used to irradiate patients with brain tumors such as GBM. For this purpose, we have studied three different neutrons moderators (H(2)O, D(2)O and BeO) and their combinations, four reflectors (Al(2)O(3), C, Bi, and Pb) and two filters (Cd and Bi). Results of calculation showed that the best obtained assembly configuration corresponds to the combination of the three moderators H(2)O, BeO and D(2)O jointly to Al(2)O(3) reflector and two filter Cd+Bi optimize the spectrum of the epithermal neutron at 72%, and minimize the thermal neutron to 4% and thus it can be used to treat the deep tumor brain. The calculations have been performed by means of the Monte Carlo N (particle code MCNP 5C). Our results strongly encourage further studying of irradiation of the head with epithermal neutron fields.

  7. Simultaneous thermal neutron decay time and porosity logging system

    International Nuclear Information System (INIS)

    Schultz, W.E.; Smith, H.D.; Smith, M.P.

    1980-01-01

    An improved method and apparatus are described for simultaneously measuring the porosity and thermal neutron capture cross section of earth formations in situ in the vicinity of a well borehole using pulsed neutron well logging techniques. The logging tool which is moved through the borehole consists of a 14 MeV pulsed neutron source, an epithermal neutron detector and a combination gamma ray and fast neutron detector. The associated gating systems, counters and combined digital computer are sited above ground. (U.K.)

  8. Neutron spectra and H*(10) around and 18 MV Linac by Ann's

    International Nuclear Information System (INIS)

    Banuelos F, A.; Valero L, C.; Borja H, C. G.; Hernandez D, V. M.; Vega C, H. R.

    2011-10-01

    Neutron spectra and ambient dose equivalent H*(10) were calculated for a radiotherapy room in 16 point-like detectors, 15 located inside the vault room and 1 located outside the bunker. The calculation was carried out using Monte Carlo Methods with the MCNP5 code for a generic radiotherapy room model operating with a 18 MV Linac, obtaining 16 neutron spectra with 47 energy bins, the H*(10) values were calculated from the neutron spectra by the use of the fluence-dose conversion factors. An artificial neural network were designed and trained to determine the neutron H*(10) in 15 different locations inside the vault room from the H*(10) dose calculated for the detector located outside the room, using the calculated dose values as training set, using the scaled conjugated gradient training algorithm. The mean squared error set for the network training was 1E(-14), adjusting the data in 99.992 %. In the treatment hall, as the distance respect to the isocenter is increased, the amount of neutrons and the H*(10) are reduced, neutrons in the high-energy region are shifted to lower region peaking around 0.1 MeV, however the epithermal and thermal neutrons remain constant due to the room-return effect. In the maze the spectra are dominated by epithermal and thermal neutrons that contributes to produce activation and the production of prompt gamma-rays. The results shows the using this artificial intelligence technic as a useful tool for the neutron spectrometry and dosimetry by the simplification on the neutronic fields characterization inside radiotherapy rooms avoiding the use of traditional spectrometric systems. And once the H*(10) doses have been calculated, to take the appropriated actions to reduce or prevent the patient and working staff exposure to this undesirable neutron radiation. (Author)

  9. Synthetic multi-element standards: a good tool for calibration and quality control of irradiation facilities used for neutron activation analysis

    International Nuclear Information System (INIS)

    Vermaercke, P.

    2007-01-01

    Neutron activation analysis (NAA) is a physical technique used for the absolute measurement of the concentration of substances in solids and liquids. The method uses neutron irradiation which is commonly realised using a nuclear reactor in order to activate (make radioactive) different isotopes of the elements present in the sample. The radionuclides produced in this way emit gamma-rays that are characteristic of the elements present in the sample. Using gamma-ray spectrometry these radionuclides can then be identified and quantified, and hence their concentration in the sample can be determined. Although NAA is a straightforward method it requires a sound control of the many physical parameters involved to obtain accurate results and to guarantee a set accuracy in routine analysis. The accuracy of NAA depends on the specific measurement method used. One can perform NAA in a relative way by co-irradiating a known standard and the unknown sample in the same conditions and by comparing the ratio of gamma-rays they emit. Relative NAA has limited applicability since it requires reference standards with a comparable composition as the unknown. A more generally applicable method is the k0-NAA method. In the k0-NAA method all measurements are relative to the element Au resulting in 198Au when irradiated. The k0-NAA method further relies on the fact that the neutron energy spectrum produced in a given position in the reactor can be parameterised with two parameters: the shape factor of the epithermal neutron flux, indicating the deviation of the epithermal neutron spectrum from the ideal 1/E shape approximated by a 1/E1+a distribution, with E the neutron energy; f: the thermal-to-epithermal neutron flux ratio. The parameters f and a are characteristic for the irradiation facility (reactor and irradiation channels) and may change or fluctuate in time according to the irradiation conditions. The way elements activate (become radioactive) when interacting with neutrons is

  10. Dosimetry methods in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G.; Artuso, E.; Felisi, M.; Regazzoni, V.; Giove, D. [Universita degli Studi di Milano, Department of Physics, Via Festa del Patrono 7, 20122 Milano (Italy); Agosteo, S.; Barcaglioni, L. [Istituto Nazionale di Fisica Nucleare, Milano (Italy); Campi, F.; Garlati, L. [Politecnico di Milano, Energy Department, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); De Errico, F. [Universita degli Studi di Pisa, Department of Civil and Industrial Engineering, Lungamo Pacinotti 43, 56126 Pisa (Italy); Borroni, M.; Carrara, M. [Fondazione IRCCS Istituto Nazionale Tumori, Medical Physics Unit, Via Venezian 1, 20133 Milano (Italy); Burian, J.; Klupak, V.; Viererbl, L.; Marek, M. [Research Centre Rez, Department of Neutron Physics, 250-68 Husinec-Rez (Czech Republic)

    2014-08-15

    Dosimetry studies have been carried out at thermal and epithermal columns of Lvr-15 research reactor for investigating the spatial distribution of gamma dose, fast neutron dose and thermal neutron fluence. Two different dosimetry methods, both based on solid state detectors, have been studied and applied and the accuracy and consistency of the results have been inspected. One method is based on Fricke gel dosimeters that are dilute water solutions and have good tissue equivalence for neutrons and also for all the secondary radiations produced by neutron interactions in tissue or water phantoms. Fricke gel dosimeters give the possibility of separating the various dose contributions, i.e. the gamma dose, the fast neutron dose and the dose due to charged particles generated during thermal neutron reactions by isotopes having high cross section, like 10-B. From this last dose, thermal neutron fluence can be obtained by means of the kerma factor. The second method is based on thermoluminescence dosimeters. In particular, the developed method draw advantage from the different heights of the peaks of the glow curve of such phosphors when irradiated with photons or with thermal neutrons. The results show that satisfactory results can be obtained with simple methods, in spite of the complexity of the subject. However, the more suitable dosimeters and principally their utilization and analysis modalities are different for the various neutron beams, mainly depending on the relative intensities of the three components of the neutron field, in particular are different for thermal and epithermal columns. (Author)

  11. Dosimetry methods in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Gambarini, G.; Artuso, E.; Felisi, M.; Regazzoni, V.; Giove, D.; Agosteo, S.; Barcaglioni, L.; Campi, F.; Garlati, L.; De Errico, F.; Borroni, M.; Carrara, M.; Burian, J.; Klupak, V.; Viererbl, L.; Marek, M.

    2014-08-01

    Dosimetry studies have been carried out at thermal and epithermal columns of Lvr-15 research reactor for investigating the spatial distribution of gamma dose, fast neutron dose and thermal neutron fluence. Two different dosimetry methods, both based on solid state detectors, have been studied and applied and the accuracy and consistency of the results have been inspected. One method is based on Fricke gel dosimeters that are dilute water solutions and have good tissue equivalence for neutrons and also for all the secondary radiations produced by neutron interactions in tissue or water phantoms. Fricke gel dosimeters give the possibility of separating the various dose contributions, i.e. the gamma dose, the fast neutron dose and the dose due to charged particles generated during thermal neutron reactions by isotopes having high cross section, like 10-B. From this last dose, thermal neutron fluence can be obtained by means of the kerma factor. The second method is based on thermoluminescence dosimeters. In particular, the developed method draw advantage from the different heights of the peaks of the glow curve of such phosphors when irradiated with photons or with thermal neutrons. The results show that satisfactory results can be obtained with simple methods, in spite of the complexity of the subject. However, the more suitable dosimeters and principally their utilization and analysis modalities are different for the various neutron beams, mainly depending on the relative intensities of the three components of the neutron field, in particular are different for thermal and epithermal columns. (Author)

  12. Remarks on some rock neutron parameters

    International Nuclear Information System (INIS)

    Czubek, J.A.

    1984-01-01

    A method to calculate the thermal neutron parameters of rocks is given in the paper. It is based on a proper energy averaging of cross-sections for all rock matrix and rock saturating liquid constituents. The diffusion lengths in different lithologies in function of the variable rock porosity have been calculated. An influence of the thermal neutron spectrum on the shape of the porosity calibration curves for the dual spacing neutron method is shown. Magmatic rocks as a possible source of geothermal energy are now becoming a target of neutron loggings for the porosity determination. Here the knowledge of the slowing-down lengths is of great importance in the problem of the estimation of the calibration curves. A semi-analytical approach to get this parameter is given in the paper. It was found, as far as concerns the slowing-down of fast neutrons, that all magmatic rocks behave as sandstone with, however, different content of bound water in the rock matrix and different rock matrix density. Some neutron methods are based on the detection of epithermal neutrons. For theoretical considerations it is important to know the physical meaning of the registered signal. From the discussion of experimental data reported in the literature it seems that it is the slowing-down density that is the physical quantity being measured. This conclusion has a very important practical implication - the porosity calibration curves depend upon the slowing-down length alone and are independent of the slowing-down cross-section for epithermal neutrons

  13. Epithermal neutron activation analysis of major and trace elements in Red Sea scleractinian corals

    International Nuclear Information System (INIS)

    Abdo, S.Y.; Sherif, M.M.; Frontasyeva, M.V.

    2017-01-01

    Five corals belonging to common scleractinian reef-building species, and collected from Gulf of Suez, Egypt were subjected to neutron activation analysis. The content of 26 elements: Na, Mg, Cl, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Zn, As, Br, Rb, Sr, Sb, I, Cs, Ba, La, Ce, Gd, Hf, Th, and U was experimentally determined. Ca and Sr have the highest content i.e. 38.4-39.5% and 0.73-0.78% respectively while, the content of all other elements was within the ranges reported for the worldwide corals. For a better understanding of the coral exoskeleton elemental content, the partition coefficient calculated for all determined elements showed a wide range of values varying from 2 × 10 -4 in the case of Cl to 2 × 10 3 for Ce and other insoluble elements. Although all corals were collected in the vicinity of the Port Suez no traces of anthropogenic contamination were evidenced. (author)

  14. Investigation of ancient pottery from Lefkanti, Greece, by epithermal gamma spectroscopy using loss-free counting technology

    International Nuclear Information System (INIS)

    Ochsenkuehn, K.M.; Zouridakis, N.

    1996-01-01

    For the analysis of pottery fragments from ancient Lefkanti, instrumental neutron activation analysis was used. To have a good throughput of samples, a detectable series of short-lived isotopes was selected for the investigation. The problem of the initial high radioactivity, which normally hinders a fast γ-spectroscopic analysis, was eluded by using loss-free counting technology. This technology allows the measurement of pottery samples of about 100 mg size 1 day after a 30 min epithermal irradiation. Up to 15 samples could be analyzed in one day under these working conditions, having the possibility to analyze the elements As, Eu, Ga, Gd, La, Mn, Sb, Sm, Th, U, W and Zn, which are enough to perform statistical characterizations of potteries. (author). 11 refs., 2 figs., 1 tab

  15. Neutron and gamma-ray spectra of 239PuBe and 241AmBe

    International Nuclear Information System (INIS)

    Vega-Carrillo, H.R.; Manzanares-Acuna, Eduardo; Becerra-Ferreiro, A.M.; Carrillo-Nunez, Aureliano

    2002-01-01

    Neutron and gamma-ray spectra of 239 PuBe and 241 AmBe were measured and their dosimetric features were calculated. Neutron spectra were measured using a multisphere neutron spectrometer with a 6 LiI(Eu) scintillator. The 239 PuBe neutron spectrum was measured in an open environment, while the 241 AmBe neutron spectrum was measured in a closed environment. Gamma-ray spectra were measured using a NaI(Tl) scintillator using the same experimental conditions for both sources. The effect of measuring conditions for the 241 AmBe neutron spectrum indicates the presence of epithermal and thermal neutrons. The low-resolution neutron spectra obtained with the multisphere spectrometer allows one to calculate the dosimetric features of neutron sources. At 100 cm both sources produce approximately the same count rate as that of the 4.4 MeV gamma-ray per unit of alpha emitter activity

  16. Monte Carlo simulation of a coded-aperture thermal neutron camera

    International Nuclear Information System (INIS)

    Dioszegi, I.; Salwen, C.; Forman, L.

    2011-01-01

    We employed the MCNPX Monte Carlo code to simulate image formation in a coded-aperture thermal-neutron camera. The camera, developed at Brookhaven National Laboratory (BNL), consists of a 20 x 17 cm"2 active area "3He-filled position-sensitive wire chamber in a cadmium enclosure box. The front of the box is a coded-aperture cadmium mask (at present with three different resolutions). We tested the detector experimentally with various arrangements of moderated point-neutron sources. The purpose of using the Monte Carlo modeling was to develop an easily modifiable model of the device to predict the detector's behavior using different mask patterns, and also to generate images of extended-area sources or large numbers (up to ten) of them, that is important for nonproliferation and arms-control verification, but difficult to achieve experimentally. In the model, we utilized the advanced geometry capabilities of the MCNPX code to simulate the coded aperture mask. Furthermore, the code simulated the production of thermal neutrons from fission sources surrounded by a thermalizer. With this code we also determined the thermal-neutron shadow cast by the cadmium mask; the calculations encompassed fast- and epithermal-neutrons penetrating into the detector through the mask. Since the process of signal production in "3He-filled position-sensitive wire chambers is well known, we omitted this part from our modeling. Simplified efficiency values were used for the three (thermal, epithermal, and fast) neutron-energy regions. Electronic noise and the room's background were included as a uniform irradiation component. We processed the experimental- and simulated-images using identical LabVIEW virtual instruments. (author)

  17. Filtered epithermal quasi-monoenergetic neutron beams at research reactor facilities.

    Science.gov (United States)

    Mansy, M S; Bashter, I I; El-Mesiry, M S; Habib, N; Adib, M

    2015-03-01

    Filtered neutron techniques were applied to produce quasi-monoenergetic neutron beams in the energy range of 1.5-133keV at research reactors. A simulation study was performed to characterize the filter components and transmitted beam lines. The filtered beams were characterized in terms of the optimal thickness of the main and additive components. The filtered neutron beams had high purity and intensity, with low contamination from the accompanying thermal emission, fast neutrons and γ-rays. A computer code named "QMNB" was developed in the "MATLAB" programming language to perform the required calculations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. A pulsed neutron Ramsey's method

    Energy Technology Data Exchange (ETDEWEB)

    Masuda, Y. [High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba-shi, Ibaraki 305-0801 (Japan)]. E-mail: yasuhiro.masuda@kek.jp; Ino, T. [High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba-shi, Ibaraki 305-0801 (Japan); Jeong, S.C. [High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba-shi, Ibaraki 305-0801 (Japan); Muto, S. [High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba-shi, Ibaraki 305-0801 (Japan); Skoy, V. [Joint Institute for Nuclear Reasearch, 141980 Dubna (Russian Federation); Watanabe, Y. [High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba-shi, Ibaraki 305-0801 (Japan)

    2005-02-15

    A Ramsey's method with pulsed neutrons is proposed. A Ramsey signal, which is a neutron spin rotation about a static magnetic field for a time interval between two separated oscillatory fields, is observed as a function of a neutron time of flight (TOF) in this method. The neutron spin rotation or the RF oscillation is used as a clock of the neutron velocity measurement which ranges from cold to epithermal neutron energies. This method together with the TOF measurement can be used for neutron inelastic scattering experiments. In addition, this method can be applied to the measurement of magnetic and pseudomagnetic fields in matter, and also to neutron spin manipulation for spin dependent scattering.

  19. Neutron flux and gamma dose measurement in the BNCT irradiation facility at the TRIGA reactor of the University of Pavia

    Science.gov (United States)

    Bortolussi, S.; Protti, N.; Ferrari, M.; Postuma, I.; Fatemi, S.; Prata, M.; Ballarini, F.; Carante, M. P.; Farias, R.; González, S. J.; Marrale, M.; Gallo, S.; Bartolotta, A.; Iacoviello, G.; Nigg, D.; Altieri, S.

    2018-01-01

    University of Pavia is equipped with a TRIGA Mark II research nuclear reactor, operating at a maximum steady state power of 250 kW. It has been used for many years to support Boron Neutron Capture Therapy (BNCT) research. An irradiation facility was constructed inside the thermal column of the reactor to produce a sufficient thermal neutron flux with low epithermal and fast neutron components, and low gamma dose. In this irradiation position, the liver of two patients affected by hepatic metastases from colon carcinoma were irradiated after borated drug administration. The facility is currently used for cell cultures and small animal irradiation. Measurements campaigns have been carried out, aimed at characterizing the neutron spectrum and the gamma dose component. The neutron spectrum has been measured by means of multifoil neutron activation spectrometry and a least squares unfolding algorithm; gamma dose was measured using alanine dosimeters. Results show that in a reference position the thermal neutron flux is (1.20 ± 0.03) ×1010 cm-2 s-1 when the reactor is working at the maximum power of 250 kW, with the epithermal and fast components, respectively, 2 and 3 orders of magnitude lower than the thermal component. The ratio of the gamma dose with respect to the thermal neutron fluence is 1.2 ×10-13 Gy/(n/cm2).

  20. Thermal neutron standard fields with the KUR heavy water facility

    International Nuclear Information System (INIS)

    Kanda, K.; Kobayashi, K.; Shibata, T.

    1978-01-01

    A heavy water facility attached to the KUR (Kyoto University Reactor, swimming pool type, 5 MW) yields pure thermal neutrons in the Maxwellian distribution. The facility is faced to the core of KUR and it contains about 2 tons of heavy water. The thickness of the layer is about 140 cm. The neutron spectrum was measured with the time of flight technique using a fast chopper. The measured spectrum was in good agreement with the Maxwellian distribution in all energy region for thermal neutrons. The neutron temperature was slightly higher than the heavy water temperature. The contamination of epithermal and fast neutrons caused by photo-neutrons of the γ-n reaction of heavy water was very small. The maximum intensity of thermal neutrons is 3x10 11 n/cm 2 sec. When the bismuth scatterer is attached, the gamma rays contamination is eliminated by the ratio of 0.05 of gamma rays to neutrons in rem. This standard neutron field has been used for such experiments as thermal neutron cross section measurement, detector calibration, activation analysis, biomedical purposes etc. (author)

  1. Evaluation of heavy metal uptake in micropterus salmoides (Largemouth Bass) of Lake Austin, TX by neutron activation analysis

    International Nuclear Information System (INIS)

    Weaver, J.; Wilson, W.H.; Biegalski, S.R.F.; O'Kelly, D.J.

    2009-01-01

    Neutron activation analysis was used to investigate and quantify the level of heavy metal uptake in the marine environment of Lake Austin in Austin, TX. Specifically, the samples studied were largemouth bass, or micropterus salmoides. The presence of heavy metals in the food chain presents multiple hazards, mostly as a food hazard for those species that ingest the fish, namely humans. To measure the concentrations of heavy metals in various fish samples, the nuclear analytical technique of neutron activation analysis (NAA) was used. Both epithermal and thermal irradiations were conducted for the NAA to look for short and long-lived radioisotopes, respectively. The samples themselves consisted of liver and tissue samples for each of the fish caught. Each sample was freeze-dried and homogenized before irradiation and spectrum acquisition. The results showed that all levels of heavy metals were not sufficient enough to make the fish unsafe for eating, with the highest levels being found for iron and zinc. Gold was found to be at much higher concentrations in the younger fish and virtually non-existent in the larger of the samples. (author)

  2. Triga IPR-R1 neutron beam: increasing the thematic of applications in CDTN

    International Nuclear Information System (INIS)

    Sebastiao, Rita de C.O.; Rodrigues, Rogerio R.; Leal, Alexandre S.

    2007-01-01

    The neutron flux in a research reactor can be used in several applications such as the neutron activation analysis, the radioisotopes production, study of DNA and protein structures, doping of silicon and neutron radiography. The enhancement of the nuclear research reactor utilization with the introduction of new applications would be possible with the availability of a neutron beam and with the neutron energy spectra completely characterized. This work evaluates the use of TRIGA reactor of CDTN/CNEN as a source of neutron beam. The readiness of a neutron beam with appropriate intensity and energy spectrum would make possible the increasing of the thematic of applications and researches in this reactor. The main contribution to this theme is to evaluate the thermal and epithermal neutron flux in the vertical extractor of the TRIGA IPR-R1. The simulation was performed in this work using the MCNP code. (author)

  3. Advanced spallation neutron sources for condensed matter research

    International Nuclear Information System (INIS)

    Lovesey, S.W.; Stirling, G.C.

    1984-03-01

    Advanced spallation neutron sources afford significant advantages over existing high flux reactors. The effective flux is much greater than that currently available with reactor sources. A ten-fold increase in neutron flux will be a major benefit to a wide range of condensed matter studies, and it will realise important experiments that are marginal at reactor sources. Moreover, the high intensity of epithermal neutrons open new vistas in studies of electronic states and molecular vibrations. (author)

  4. Moderator material for neutrons and use of said material

    International Nuclear Information System (INIS)

    Hiismaeki, P.; Auterinen, I.

    1994-01-01

    The invention concerns a moderator material used for mediation of high-velocity neutrons, in particular of fission neutrons, to epithermal neutrons. The principal components of the moderator material are aluminum fluoride and aluminum metal, which have been formed into a dense composite substantially free of pores, wherein the material contains 20-50 percent-vol. of aluminum metal and 80-50 percent-vol. aluminum fluoride. Further, the use of the moderator material in accordance with the invention in neutron capture therapy of cancer tumours is described, such as in boron neutron capture therapy (BNCT)

  5. Design of incoming neutron-beam for detecting oil dirt

    International Nuclear Information System (INIS)

    Zhao Jingwu; Chen Xiaocheng; Alimujiang Naimaiti; Aierken Abuliemu

    2012-01-01

    For the technique of neutron back-scattering, the neutron counts are non-linear and have a tendency toward saturation because of the neutron self-shielding. As a result, the measurement accuracy is reduced and the measurement range is limited. Using a simply model and comparing with experimental data, it is shown that, in the measurement of the thickness of oil dirt, by adjusting the ratio of thermal to epithermal neutrons, the neutron self: shielding is weakened. As a result, the non-linearity can be reduced and the measurement accuracy and range can be improved. (authors)

  6. Nanogram determination of arsenic in biological reference materials by non-destructive Compton suppression neutron activation analysis

    International Nuclear Information System (INIS)

    Petra, M.; Landsberger, S.; Swift, G.

    1990-01-01

    Non-destructive epithermal neutron activation analysis in conjunction with Compton suppression has been applied to determine arsenic in seven biological standard reference materials from the National Institute of Standards and Technology. The accuracy is in excellent agreement with all the certified values and compilation results. For four of the materials detection limits between 1-4 ng/g were easily achieved while for three others they ranged from 18-50 ng/g. Overall analytical precision typically varied between 2-4% for five of the reference materials while for two other it was between 12-16%. These methods clearly demonstrate that through a judicious approach of anti-coincidence techniques, nanogram quantities of arsenic can be reliably determined without the need for labor intensive chemical separations. (orig.)

  7. Compton suppression method and epithermal NAA in the determination of nutrients and heavy metals in Nigerian food and beverages

    International Nuclear Information System (INIS)

    Ahmed, Y.A.; Landsberger, S.; O'Kelly, D.J.; Braisted, J.; Gabdo, H.; Ewa, I.O.B.; Umar, I.M.; Funtua, I.I.

    2010-01-01

    We used in this study Compton suppression method and epithermal neutron activation analysis to determine the concentration of nutrients and heavy metals in Nigerian food and beverages. The work was performed at the University of Texas TRIGA Reactor by short, medium, and long irradiation protocols, using thermal flux of 1.4x10 12 n cm -2 s -1 and epithermal flux of 1.4x10 11 n cm -2 s -1 . Application of Compton suppression method has reduced interferences from Compton scattered photons thereby allowing easy evaluation of Na, Cl, Ca, Cu, Mn, Mg, Co, Cr, Rb, Fe, and Se. The epithermal NAA method has enabled determination of Cd, As, Ba, Sr, Br, I, and V with little turn-around time. Quality Control and Quality Assurance of the method was tested by analyzing four Standard Reference Materials (non-fat powdered milk, apple leaves, citrus leaves, and peach leaves) obtained from National Institute for Standards and Technology. Our results show that sorghum, millet, and maize have high values of Zn, Mn, Fe, low values of Cd, As, and Se. Powdered milks, rice, beans, and soybeans were found to have moderate amounts of all the elements. Tobacco recorded high content of Cd, Mn, and As, whereas tea, tsobo leaves, Baobab leaves, and okro seed have more As values than others. However, biscuits, macaroni, spaghetti, and noodles show lower concentrations of all the elements. The distribution of these nutrients and heavy metals in these food and beverages shows the need to fortify biscuits and pastas with micro and macro-nutrients and reduce the use of tobacco, tea, tsobo leaves, Baobab leaves, and Okro seed to avoid intake of heavy elements.

  8. Liquid Li based neutron source for BNCT and science application.

    Science.gov (United States)

    Horiike, H; Murata, I; Iida, T; Yoshihashi, S; Hoashi, E; Kato, I; Hashimoto, N; Kuri, S; Oshiro, S

    2015-12-01

    Liquid lithium (Li) is a candidate material for a target of intense neutron source, heat transfer medium in space engines and charges stripper. For a medical application of BNCT, epithermal neutrons with least energetic neutrons and γ-ray are required so as to avoid unnecessary doses to a patient. This is enabled by lithium target irradiated by protons at 2.5 MeV range, with utilizing the threshold reaction of (7)Li(p,n)(7)Be at 1.88 MeV. In the system, protons at 2.5 MeV penetrate into Li layer by 0.25 mm with dissipating heat load near the surface. To handle it, thin film flow of high velocity is important for stable operation. For the proton accelerator, electrostatic type of the Schnkel or the tandem is planned to be employed. Neutrons generated at 0.6 MeV are gently moderated to epithermal energy while suppressing accompanying γ-ray minimum by the dedicated moderator assembly. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Neutron spectra and H*(10) around and 18 MV Linac by Ann's

    Energy Technology Data Exchange (ETDEWEB)

    Banuelos F, A.; Valero L, C.; Borja H, C. G.; Hernandez D, V. M.; Vega C, H. R., E-mail: alanb535@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2011-10-15

    Neutron spectra and ambient dose equivalent H*(10) were calculated for a radiotherapy room in 16 point-like detectors, 15 located inside the vault room and 1 located outside the bunker. The calculation was carried out using Monte Carlo Methods with the MCNP5 code for a generic radiotherapy room model operating with a 18 MV Linac, obtaining 16 neutron spectra with 47 energy bins, the H*(10) values were calculated from the neutron spectra by the use of the fluence-dose conversion factors. An artificial neural network were designed and trained to determine the neutron H*(10) in 15 different locations inside the vault room from the H*(10) dose calculated for the detector located outside the room, using the calculated dose values as training set, using the scaled conjugated gradient training algorithm. The mean squared error set for the network training was 1E(-14), adjusting the data in 99.992 %. In the treatment hall, as the distance respect to the isocenter is increased, the amount of neutrons and the H*(10) are reduced, neutrons in the high-energy region are shifted to lower region peaking around 0.1 MeV, however the epithermal and thermal neutrons remain constant due to the room-return effect. In the maze the spectra are dominated by epithermal and thermal neutrons that contributes to produce activation and the production of prompt gamma-rays. The results shows the using this artificial intelligence technic as a useful tool for the neutron spectrometry and dosimetry by the simplification on the neutronic fields characterization inside radiotherapy rooms avoiding the use of traditional spectrometric systems. And once the H*(10) doses have been calculated, to take the appropriated actions to reduce or prevent the patient and working staff exposure to this undesirable neutron radiation. (Author)

  10. Reactor neutron activation for multielemental analysis

    International Nuclear Information System (INIS)

    Reddy, A.V.R.

    1999-01-01

    Neutron Activation Analysis using single comparator (K 0 NAA method) has been used for obtaining multielemental profiles in a variety of matrices related to environment. Gold was used as the comparator. Neutron flux was characterised by determining f, the epithermal to thermal neutron flux ratio and cc, the deviation from ideal shape of the neutron spectrum. The f and a were determined in different irradiation positions in APSARA reactor, PCF position in CIRUS reactor and tray rod position in Dhruva reactor using both cadmium cut off and multi isotope detector methods. High resolution gamma ray spectrometry was used for radioactive assay of the activation products. This technique is being used for multielement analysis in a variety of matrices like lake sediments, sea nodules and crusts, minerals, leaves, cereals, pulses, leaves, water and soil. Elemental profiles of the sediments corresponding to different depths from Nainital lake were determined and used to understand the history of natural absorption/desorption pattern of the previous 160 years. Ferromanganese crusts from different locations of Indian Ocean were analysed with a view to studying the distribution of some trace elements along with Fe and Mn. Variation of Mn/Fe ratio was used to identify the nature of the crusts as hydrogenous or hydrothermal. Fe-rich and Fe-depleted nodules from Indian Ocean were analysed to understand the REE patterns and it is proposed that REE-Th associated minerals could be the potential Th contributors to the sea water and thus reached ferromanganese nodules. Dolomites (unaltered and altered), two types of serpentines and intrusive rock dolerite from the asbestos mines of Cuddapah basin were analysed for major, minor and trace elements. The elemental concentrations are used for distinguishing and characterising these minerals. From our investigations, it was concluded that both dolomite and dolerite contribute elements in the serpentinisation process. Chemical neutron

  11. Epithermal/fast neutron cyclic activation analysis for the determination of fluorine in environmental and industrial materials

    International Nuclear Information System (INIS)

    Parry, S.J.; Benzing, R.; Bolstad, K.L.; Steinnes, E.

    2000-01-01

    Pseudocyclic activation analysis (12-second irradiation, 12-second count, 5 cycles, 25 minutes between cycles) is used to determine fluorine in plastic and rubber with detection limits in the range 15-40 mg/kg. The detection of fluorine in materials containing high concentrations of aluminum is improved using the 19 F(n,p) 19 O reaction, induced by fast neutrons, (30-second irradiation, 30-second count, 25-minute decay between cycles). The method was applied to a biomonitoring survey in the vicinity of an aluminum smelter in the Ardal region, Norway. The fluorine concentration in the moss and soil samples could be determined in all samples above the detection limits of 50 and 100 mg/kg, respectively. (author)

  12. The final power calibration of the IPEN/MB-01 nuclear reactor for various configurations obtained from the measurements of the absolute average neutron flux

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Alexandre Fonseca Povoa da, E-mail: alexandre.povoa@mar.mil.br [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), Sao Paulo, SP (Brazil); Bitelli, Ulysses d' Utra; Mura, Luiz Ernesto Credidio; Lima, Ana Cecilia de Souza; Betti, Flavio; Santos, Diogo Feliciano dos, E-mail: ubitelli@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The use of neutron activation foils is a widely spread technique applied to obtain nuclear parameters then comparing the results with those calculated using specific methodologies and available nuclear data. By irradiation of activation foils and subsequent measurement of its induced activity, it is possible to determine the neutron flux at the position of irradiation. The power level during operation of the reactor is a parameter which is directly proportional to the average neutron flux throughout the core. The objective of this work is to gather data from irradiation of gold foils symmetrically placed along a cylindrically configured core which presents only a small excess reactivity in order to derive the power generated throughout the spatial thermal and epithermal neutron flux distribution over the core of the IPEN/MB-01 Nuclear Reactor, eventually lending to a proper calibration of its nuclear channels. The foils are fixed in a Lucite plate then irradiated with and without cadmium sheaths so as to obtain the absolute thermal and epithermal neutron flux. The correlation between the average power neutron flux resulting from the gold foils irradiation, and the average power digitally indicated by the nuclear channel number 6, allows for the calibration of the nuclear channels of the reactor. The reactor power level obtained by thermal neutron flux mapping was (74.65 ± 2.45) watts to a mean counting per seconds of 37881 cps to nuclear channel number 10 a pulse detector, and 0.719.10{sup -5} ampere to nuclear linear channel number 6 (a non-compensated ionization chamber). (author)

  13. Self-shielding and burn-out effects in the irradiation of strongly-neutron-absorbing material

    International Nuclear Information System (INIS)

    Sekine, T.; Baba, H.

    1978-01-01

    Self-shielding and burn-out effects are discussed in the evaluation of radioisotopes formed by neutron irradiation of a strongly-neutron-absorbing material. A method of the evaluation of such effects is developed both for thermal and epithermal neutrons. Gadolinium oxide uniformly mixed with graphite powder was irradiated by reactor-neutrons together with pieces of a Co-Al alloy wire (the content of Co being 0.475%) as the neutron flux monitor. The configuration of the samples and flux monitors in each of two irradiations is illustrated. The yields of activities produced in the irradiated samples were determined by the γ-spectrometry with a Ge(Li) detector of a relative detection efficiency of 8%. Activities at the end of irradiation were estimated by corrections due to pile-up, self-absorption, detection efficiency, branching ratio, and decay of the activity. Results of the calculation are discussed in comparison with the observed yields of 153 Gd, 160 Tb, and 161 Tb for the case of neutron irradiation of disc-shaped targets of gadolinium oxide. (T.G.)

  14. High Conduction Neutron Absorber to Simulate Fast Reactor Environment in an Existing Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Guillen, Donna; Greenwood, Lawrence R.; Parry, James

    2014-06-22

    A need was determined for a thermal neutron absorbing material that could be cooled in a gas reactor environment without using large amounts of a coolant that would thermalize the neutron flux. A new neutron absorbing material was developed that provided high conduction so a small amount of water would be sufficient for cooling thereby thermalizing the flux as little as possible. An irradiation experiment was performed to assess the effects of radiation and the performance of a new neutron absorbing material. Neutron fluence monitors were placed inside specially fabricated holders within a set of drop-in capsules and irradiated for up to four cycles in the Advanced Test Reactor. Following irradiation, the neutron fluence monitor wires were analyzed by gamma and x-ray spectrometry to determine the activities of the activation products. The adjusted neutron fluences were calculated and grouped into three bins – thermal, epithermal and fast to evaluate the spectral shift created by the new material. Fluence monitors were evaluated after four different irradiation periods to evaluate the effects of burn-up in the absorbing material. Additionally, activities of the three highest activity isotopes present in the specimens are given.

  15. Neutron field features in a calibration hall

    International Nuclear Information System (INIS)

    Vega C, H.R.; Gallego, E.; Lorente, A.

    2004-01-01

    A new source facility ( 241 Am-Be) has been installed in a large size bunker-type room. To characterize the neutron fields in the facility, detailed calculations have been made with MCNP-4C, showing the different components of the neutron radiation reaching the reference points (direct, in scattered, backscattered). The contribution from neutrons scattered in the walls to the total ambient dose equivalent remains reasonably low ( 6 LiI(Eu) scintillator (0.4 cm 0 x 0.4 cm), UTA4 response matrix and BUNKIUT unfolding code. The calculated and experimentally obtained spectra are compared, with small differences found in the epithermal and thermal region, attributable to the concrete composition used in the calculations. The H*(10) rate has been determined from the spectra, and then compared to the reading of an active dosemeter (LB 6411), with differences found lower than 8%. (Author)

  16. Fuel assembly inspection by three-dimensional neutron radiography

    International Nuclear Information System (INIS)

    Lapinski, N.P.; Reimann, K.J.; Berger, H.

    1979-01-01

    Radiographic inspection of complex objects such as fuel subassemblies often presents problems because superimposition of images at different depths in the object complicates interpretation. One method for obtaining and displaying three-dimensional neutron radiographic images in multiple-film laminagraphy; a series of radiographs generated at different angular orientations are superimposed to provide focussed images of any object plane. In the present work multiple-film neutron laminagraphs were generated using direct and indirect exposure techniques, with neutrons in thermal, epithermal, and fast energy ranges

  17. Feasibility of sealed D-T neutron generator as neutron source for liver BNCT and its beam shaping assembly.

    Science.gov (United States)

    Liu, Zheng; Li, Gang; Liu, Linmao

    2014-04-01

    This paper involves the feasibility of boron neutron capture therapy (BNCT) for liver tumor with four sealed neutron generators as neutron source. Two generators are placed on each side of the liver. The high energy of these emitted neutrons should be reduced by designing a beam shaping assembly (BSA) to make them useable for BNCT. However, the neutron flux decreases as neutrons pass through different materials of BSA. Therefore, it is essential to find ways to increase the neutron flux. In this paper, the feasibility of using low enrichment uranium as a neutron multiplier is investigated to increase the number of neutrons emitted from D-T neutron generators. The neutron spectrum related to our system has a proper epithermal flux, and the fast and thermal neutron fluxes comply with the IAEA recommended values. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Fundamental of neutron radiography and the present of neutron radiography in Japan

    International Nuclear Information System (INIS)

    Sekita, Junichiro

    1988-01-01

    Neutron radiography refers to the application of transmitted neutrons to analysis. In general, thermal neutron is used for neutron radiography. Thermal neutron is easily absorbed by light atoms, including hydrogen, boron and lithium, while it is not easily absorbed by such heavy atoms as tungsten, lead and uranium, permitting detection of impurities in heavy metals. Other neutrons than thermal neutron can also be applied. Cold neutron is produced from fast neutron using a moderator to reduce its energy down to below that of thermal neutron. Cold neutron is usefull for analysis of thick material. Epithermal neutron can induce resonance characteristic of each substance. With a relatively small reaction area, fast neutron permits observation of thick samples. Being electrically neutral, neutrons are difficult to detect by direct means. Thus a substance that releases charged particles is put in the path of neutrons for indirect measurement. X-ray film combined with converter screen for conversion of neutrons to charge particles is placed behind the sample. Photographing is carried out by a procedure similar to X-ray photography. Major institues and laboratories in Japan provided with neutron radiography facilities are listed. (Nogami, K.)

  19. Activation neutron detector

    International Nuclear Information System (INIS)

    Ambardanishvili, T.S.; Kolomiitsev, M.A.; Zakharina, T.Y.; Dundua, V.J.; Chikhladze, N.V.

    1976-01-01

    An activation neutron detector made as a moulded and cured composition of a material capable of being neutron-activated is described. The material is selected from a group consisting of at least two chemical elements, a compound of at least two chemical elements and their mixture, each of the chemical elements and their mixture, each of the chemical elements being capable of interacting with neutrons to form radioactive isotopes having different radiation energies when disintegrating. The material capable of being neutron-activated is distributed throughout the volume of a polycondensation resin inert with respect to neutrons and capable of curing. 17 Claims, No Drawings

  20. Development of a new electronic neutron imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Brenizer, J.S. [Department of Mechanical, Aerospace and Nuclear Engineering, Thornton Hall, University of Virginia, Charlottesville, VA 22903-2442 (United States); Berger, H. [Industrial Quality, Inc., Gaithersburg, MD (United States); Gibbs, K.M. [Industrial Quality, Inc., Gaithersburg, MD (United States); Mengers, P. [Paultek Systems, Inc., Nevada City, CA (United States); Stebbings, C.T. [Department of Mechanical, Aerospace and Nuclear Engineering, Thornton Hall, University of Virginia, Charlottesville, VA 22903-2442 (United States); Polansky, D. [Industrial Quality, Inc., Gaithersburg, MD (United States); Rogerson, D.J. [Naval Air Warfare Center, China Lake, CA (United States)

    1999-11-03

    An electronic neutron imaging camera system was developed for use with thermal, epithermal, and fast neutrons in applications that include nondestructive inspection of explosives, corrosion, turbine blades, electronics, low Z components, etc. The neutron images are expected to provide information to supplement that available from X-ray tests. The primary camera image area was a 30x30 cm field-of-view with a spatial resolution approaching 1.6 line pairs/mm (lp/mm). The camera had a remotely changeable second lens to limit the field-of-view to 7.6x7.6 cm for high spatial resolution (at least 4 lp/mm) thermal neutron imaging, but neutron and light scatter will limit resolution for fast neutrons to about 0.5 lp/mm. Remote focus capability enhanced camera set-up for optimum operation. The 75 dB dynamic range camera system included {sup 6}Li-based screens for imaging of thermal and epithermal neutrons and ZnS(Ag)-based screens for fast neutron imaging. The fast optics was input to a Super S-25 Gen II image intensifier, fiber optically coupled to a 1134 (h)x486 (v) frame transfer CCD camera. The camera system was designed to be compatible with a Navy-sponsored accelerator neutron source. The planned neutron source is an RF quadrupole accelerator that will provide a fast neutron flux of 10{sup 7} n/cm{sup 2}-s (at a source distance of 1 m) at an energy of about 2.2 MeV and a thermal neutron flux of 10{sup 6} n/cm{sup 2}-s at a source L/D ratio of 30. The electronic camera produced good quality real-time images at these neutron levels. On-chip integration could be used to improve image quality for low flux situations. The camera and accelerator combination provided a useful non-reactor neutron inspection system.

  1. DAWN GRAND MAP CERES TPE NEUTRON COUNTS V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — A global map thermal+epithermal neutron counting rates binned on twenty-degree quasi-equal-area pixels is provided. The map was determined from a time series of the...

  2. Fast neutron (14.5 MeV) radiography: a comparative study

    International Nuclear Information System (INIS)

    Klann, R.T.

    1996-01-01

    Fast neutron (14.5 MeV) radiography is a type of non-destructive analysis tool that offers its own benefits and drawbacks. Because cross-sections vary with energy, a different range of materials can be examined with fast neutrons than can be studied with thermal neutrons, epithermal neutrons, or x-rays. This paper details these differences through a comparative study of fast neutron radiography to the other types of radiography available. The most obvious difference among the different types of radiography is in the penetrability of the sources. Fast neutrons can probe much deeper and can therefore obtain details of the internals of thick objects. Good images have been obtained through as much as 15 cm of steel, 10 cm of water, and 15 cm of borated polyethylene. In addition, some objects were identifiable through as much as 25 cm of water or 30 cm of borated polyethylene. The most notable benefit of fast neutron radiography is in the types of materials that can be tested. Fast neutron radiography can view through materials that simply cannot be viewed by X rays, thermal neutrons, or epithermal neutrons due to the high cross-sections or linear attenuation coefficients involved. Cadmium was totally transparent to the fast neutron source. Fast neutron radiography is not without drawbacks. The most pronounced drawback has been in the quality of radiograph produced. The image resolution is only about 0.8 mm for a 1.25 cm thick object, whereas, other forms of radiography have much better resolution

  3. Bulk hydrogen analysis, using neutrons. Final report of the second research co-ordination meeting

    International Nuclear Information System (INIS)

    1998-11-01

    The aims of the Second Co-ordination Meting (RCM) of the Coordinated Research Programme (CRP) were to report on and review progress against the work programme set at the beginning of the CRP and to discuss the work plans for the second half of the programme. In many cases hydrogen is required to be measured in a bulk medium rather than merely at a surface. For this reason neutrons are used due to their high penetrating power in dense material. In addition, the mass attenuation coefficient for neutrons in hydrogen is significantly larger than for all other elements, meaning that neutrons have a higher probability of interacting with hydrogen than with other elements in the sample matrix. Neutrons have been used in the following areas: Fast Neutron Transmission, Scattering and Activation Technique; Digital Neutron Imaging; Hydrogen Detection by Epithermal Neutrons; Microscopic Behaviour of Hydrogen in Bulk Materials

  4. Measurements of neutron flux in the RA reactor; Merenje karakteristika neutronskog fluksa u reaktoru RA

    Energy Technology Data Exchange (ETDEWEB)

    Raisic, N [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1961-12-15

    This report includes the following separate parts: Thermal neutron flux in the experimental channels od RA reactor; Epithermal neutron flux in the experimental channels od RA reactor; Fast neutron flux in the experimental channels od RA reactor; Thermal neutron flux in the thermal column and biological experimental channel; Neutronic measurements in the RA reactor cell; Temperature reactivity coefficient of the RA reactor; design of the device for measuring the activity of wire. [Serbo-Croat] Ovaj izvestaj sadrzi sledece referate: Fluks termalnih neutrona u eksperimentalnim kanalima reaktora RA; Fluks epitermalnih neutrona u eksperimentalnim kanalima reaktora RA; Fluks brzih neutrona u eksperimentalnim kanalima reaktora RA; Fluks termalnih neurona u termalnoj koloni i bioloskom eksperimentalnom kanalu; Neutronska merenja u elementarnoj celiji reaktora RA; Temperaturni koeficijent reaktivnosti reaktora RA; Projekat uredjaja za merenje radioaktivnosti zice.

  5. Determination of Al, Si and P in certified reference materials by Instrumental Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Noyori, Amanda; Saiki, Mitiko, E-mail: anoyori@gmail.com, E-mail: mitiko@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Neutron analysis activation is not commonly used for aluminum, phosphorus and silicon determination, due to the difficulty to obtain reliable results. In this study, Al was determined by measuring {sup 28}Al and the contribution of P and Si due to {sup 28}Al formed in {sup 31}P(n,α){sup 28}Al and {sup 28}Si(n,p){sup 28}Al reactions were corrected using correction factors determined experimentally. Phosphorus was determined by measuring {sup 32}P (pure beta emitter) formed in reaction {sup 31}P(n,γ){sup 32}P. Silicon was determined by epithermal neutron analysis activation (ENAA) and measuring {sup 29}Al radionuclide formed in {sup 29}Si(n,p){sup 29}Al reaction. Aliquots of certified reference materials (CRMs) and synthetic standards of the elements were irradiated together, using the pneumatic transfer station of IEA-R1 nuclear research reactor. Results obtained for biological and geological CRMs showed good precision and accuracy with |Z-score| < 2 for Al, P and Si determinations. The detection limits for Al, P and Si determinations CRMs were also evaluated. Results obtained in this study demonstrated the viability of applying INAA procedures in the determination of Al, P and Si. (author)

  6. Determination of Al, Si and P in certified reference materials by Instrumental Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Noyori, Amanda; Saiki, Mitiko

    2017-01-01

    Neutron analysis activation is not commonly used for aluminum, phosphorus and silicon determination, due to the difficulty to obtain reliable results. In this study, Al was determined by measuring "2"8Al and the contribution of P and Si due to "2"8Al formed in "3"1P(n,α)"2"8Al and "2"8Si(n,p)"2"8Al reactions were corrected using correction factors determined experimentally. Phosphorus was determined by measuring "3"2P (pure beta emitter) formed in reaction "3"1P(n,γ)"3"2P. Silicon was determined by epithermal neutron analysis activation (ENAA) and measuring "2"9Al radionuclide formed in "2"9Si(n,p)"2"9Al reaction. Aliquots of certified reference materials (CRMs) and synthetic standards of the elements were irradiated together, using the pneumatic transfer station of IEA-R1 nuclear research reactor. Results obtained for biological and geological CRMs showed good precision and accuracy with |Z-score| < 2 for Al, P and Si determinations. The detection limits for Al, P and Si determinations CRMs were also evaluated. Results obtained in this study demonstrated the viability of applying INAA procedures in the determination of Al, P and Si. (author)

  7. Spectrum shaping of accelerator-based neutron beams for BNCT

    CERN Document Server

    Montagnini, B; Esposito, J; Giusti, V; Mattioda, F; Varone, R

    2002-01-01

    We describe Monte Carlo simulations of three facilities for the production of epithermal neutrons for Boron Neutron Capture Therapy (BNCT) and examine general aspects and problems of designing the spectrum-shaping assemblies to be used with these neutron sources. The first facility is based on an accelerator-driven low-power subcritical reactor, operating as a neutron amplifier. The other two facilities have no amplifier and rely entirely on their primary sources, a D-T fusion reaction device and a conventional 2.5 MeV proton accelerator with a Li target, respectively.

  8. Large animal normal tissue tolerance with boron neutron capture.

    Science.gov (United States)

    Gavin, P R; Kraft, S L; DeHaan, C E; Swartz, C D; Griebenow, M L

    1994-03-30

    Normal tissue tolerance of boron neutron capture irradiation using borocaptate sodium (NA2B12H11SH) in an epithermal neutron beam was studied. Large retriever-type dogs were used and the irradiations were performed by single dose, 5 x 10 dorsal portal. Fourteen dogs were irradiated with the epithermal neutron beam alone and 35 dogs were irradiated following intravenous administration of borocaptate sodium. Total body irradiation effect could be seen from the decreased leukocytes and platelets following irradiation. Most values returned to normal within 40 days postirradiation. Severe dermal necrosis occurred in animals given 15 Gy epithermal neutrons alone and in animals irradiated to a total peak physical dose greater than 64 Gy in animals following borocaptate sodium infusion. Lethal brain necrosis was seen in animals receiving between 27 and 39 Gy. Lethal brain necrosis occurred at 22-36 weeks postirradiation. A total peak physical dose of approximately 27 Gy and blood-boron concentrations of 25-50 ppm resulted in abnormal magnetic resonance imaging results in 6 months postexamination. Seven of eight of these animals remained normal and the lesions were not detected at the 12-month postirradiation examination. The bimodal therapy presents a complex challenge in attempting to achieve dose response assays. The resultant total radiation dose is a composite of low and high LET components. The short track length of the boron fission fragments and the geometric effect of the vessels causes much of the intravascular dose to miss the presumed critical target of the endothelial cells. The results indicate a large dose-sparing effect from the boron capture reactions within the blood.

  9. Large animal normal tissue tolerance with boron neutron capture

    International Nuclear Information System (INIS)

    Gavin, P.R.; Swartz, C.D.; Kraft, S.L.; Briebenow, M.L.; DeHaan, C.E.

    1994-01-01

    Normal tissue tolerance of boron neutron capture irradiation using borocaptate sodium (NA 2 B 12 H 11 SH) in an epithermal neutron beam was studied. Large retriever-type dogs were used and the irradiations were performed by single dose, 5 x 10 dorsal portal. Fourteen dogs were irradiated with the epithermal neutron beam alone and 35 dogs were irradiated following intravenous administration of borocaptate sodium. Total body irradiation effect could be seen from the decreased leukocytes and platelets following irradiation. Most values returned to normal within 40 days postirradiation. Severe dermal necrosis occurred in animals given 15 Gy epithermal neutrons alone and in animals irradiated to a total peak physical dose greater than 64 Gy in animals following borocaptate sodium infusion. Lethal brain necrosis was seen in animals receiving between 27 and 39 Gy. Lethal brain necrosis occurred at 22-36 weeks postirradiation. A total peak physical dose of approximately 27 Gy and blood-boron concentrations of 25-50 ppm resulted in abnormal magnetic resonance imaging results in 6 months postexamination. Seven of eight of these animals remained normal and the lesions were not detected at the 12-month postirradiation examination. The bimodal therapy presents a complex challenge in attempting to achieve dose response assays. The resultant total radiation dose is a composite of low and high LET components. The short track length of the boron fission fragments and the geometric effect of the vessels causes much of the intravascular dose to miss the presumed critical target of the endothelial cells. The results indicate a large dose-sparing effect from the boron capture reactions within the blood. 23 refs., 6 figs., 2 tabs

  10. A neutron activation detector

    International Nuclear Information System (INIS)

    Ambardanishvili, T.S.; Kolomiitsev, M.A.; Zakharina, T.Y.; Dundua, V.J.; Chikhladze, N.V.

    1973-01-01

    The present invention concerns a neutron activation detector made from a moulded and hardened composition. According to the invention, that composition contains an activable substance constituted by at least two chemical elements and/or compounds of at least two chemical elements. Each of these chemical elements is capable of reacting with the neutrons forming radio-active isotopes with vatious levels of energy during desintegration. This neutron detector is mainly suitable for measuring integral thermal neutron and fast neutron fluxes during irradiation of the sample, and also for measuring the intensities of neutron fields [fr

  11. Development of the JAERI computational dosimetry system (JCDS) for boron neutron capture therapy. Cooperative research

    Energy Technology Data Exchange (ETDEWEB)

    Kumada, Hiroaki; Yamamoto, Kazuyoshi; Torii, Yoshiya; Uchiyama, Junzo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Matsumura, Akira; Yamamoto, Tetsuya; Nose, Tadao [Tsukuba Univ., Tsukuba, Ibaraki (Japan); Nakagawa, Yoshinobu [National Sanatorium Kagawa-Children' s Hospital, Kagawa (Japan); Kageji, Teruyoshi [Tokushima Univ., Tokushima (Japan)

    2003-03-01

    The Neutron Beam Facility at JRR-4 enables us to carry out boron neutron capture therapy with epithermal neutron beam. In order to make treatment plans for performing the epithermal neutron beam BNCT, it is necessary to estimate radiation doses in a patient's head in advance. The JAERI Computational Dosimetry System (JCDS), which can estimate distributions of radiation doses in a patient's head by simulating in order to support the treatment planning for epithermal neutron beam BNCT, was developed. JCDS is a software that creates a 3-dimentional head model of a patient by using CT and MRI images, and that generates a input data file automatically for calculation of neutron flux and gamma-ray dose distributions in the brain with the Monte Carlo code MCNP, and that displays these dose distributions on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By using CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to simulate the state of a head after its surgical processes such as skin flap opening and bone removal in the BNCT with craniotomy that are being performed in Japan. JCDS can provide information for the Patient Setting System which can support to set the patient to an actual irradiation position swiftly and accurately. This report describes basic design of JCDS and functions in several processing, calculation methods, characteristics and performance of JCDS. (author)

  12. Experimental evaluation of the neutrons flux of a irradiator with AmBe sources and its possibility of use in materials analysis

    International Nuclear Information System (INIS)

    Lima, Ruy Barros de

    2003-01-01

    This work had as a target to determine the irradiator thermal and over cadmium (epithermal and fast) neutrons flux , of the Nuclear Experimental Laboratory of the Nuclear Energy Center (CNEN) - IPEN, and the possibility of its use for Neutron Activation Analysis (NAA) by the absolute method. The neutrons flux quantification was performed indirectly by the gold naked and cadmium-covered foils activation technique. The neutrons flux was determined for two situations: with polyethylene block 5.0 cm thick and without the polyethylene block. The quantification of the elements present in the irradiated samples was obtained after the experimental determination of the incident neutrons flux in the irradiation position of the sample. Flux values along the irradiator axis were determined. Some materials were analyzed, presenting good agreement with reference values. (author)

  13. Characterisation of some exotic fruits (Morus nigra, Morus alba, Salvadora persica and Carissa opaca) used as herbal medicines by neutron activation analysis and estimation of their nutritional value

    International Nuclear Information System (INIS)

    Mohammad Wasim; Muhammad Daud; Mohammad Arif; Sajid Iqbal; Yasir Anwar

    2012-01-01

    In the under developed countries, the people of far-flung rural areas still depend to a large extent upon herbal medicines. At the foundation of usage of herbal medicine is the experience of thousands of years. The present paper deals with the characterisation of exotic fruits for essential and toxic elements. The samples include Morus nigra, Morus alba, Salvadora persica and Carissa opaca (from low and high altitude). Two standardizations of neutron activation analysis, that is, semi-absolute k 0-instrumental neutron activation analysis (k 0 -INAA) and epithermal neutron activation analysis (ENAA) were employed for the quantification of elements. The analysis methodologies were validated by analyzing the IAEA-336 (lichen) and NIST-SRM-1572 (citrus leaves). Sixteen elements including Br, Ca, Cl, Co, Cr, Fe, I, K, Mg, Mn, Na, Rb, Sb, Sc Sr, and Zn were determined in all samples. Daily intakes of various elements from the samples were measured and compared with the dietary reference intakes. Additionally, principal component analysis was performed to extract information regarding samples and elements. (author)

  14. Analysis of accelerator based neutron spectra for BNCT using proton recoil spectroscopy

    International Nuclear Information System (INIS)

    Wielopolski, L.; Ludewig, H.; Powell, J.R.; Raparia, D.; Alessi, J.G.; Lowenstein, D.I.

    1998-01-01

    Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by 10 B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider implementation of this modality in a hospital environment. For example, accelerator based neutron sources offer the possibility of tailoring the neutron beams, in terms of improved depth-dose distributions, to the individual and offer, with relative ease, the capability of modifying the neutron beam energy and port size. In previous work new concepts for compact accelerator/target configuration were published. In this work, using the Van de Graaff accelerator the authors have explored different materials for filtering and reflecting neutron beams produced by irradiating a thick Li target with 1.8 to 2.5 MeV proton beams. However, since the yield and the maximum neutron energy emerging from the Li-7(p,n)Be-7 reaction increase with increase in the proton beam energy, there is a need for optimization of the proton energy versus filter and shielding requirements to obtain the desired epithermal neutron beam. The MCNP-4A computer code was used for the initial design studies that were verified with benchmark experiments

  15. Applications of image plates in neutron radiography and neutron diffraction at BARC, Trombay

    International Nuclear Information System (INIS)

    Shaikh, A.M.

    2013-01-01

    Neutron radiography techniques based on Gd, Dy and In metallic foils and X-ray film have been used at this centre since early seventies for various NDT and R and D work in nuclear, defence and aerospace industries. In recent years use of photostimulated luminescence based phosphor imaging plate has been introduced in our work. This has enabled to achieve higher sensitivities and dynamic ranges of recording radiographs with acceptable spatial resolution. It also provides digital image information which is more convenient for quantitative evaluations. Neutron image plates have been used in variety of radiography techniques such as conventional neutron radiography (NR), neutron induced beta radiography (NIBR), hydrogen sensitive epithermal neutron radiography (HYSEN) and for neutron powder diffractometry using Apsara, CIRUS and Dhruva reactors as neutron sources. Recently the image plates have also been used for characterization of thermalized neutron beam from a plasma focus neutron source and recording neutron radiographs. Prior to the utilization image plates have been characterised for their performance. Details of the measurements and applications will be presented. (author)

  16. Compton suppression method and epithermal NAA in the determination of nutrients and heavy metals in Nigerian food and beverages

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Y.A., E-mail: yaahmed1@gmail.co [Reactor Engineering Section, Centre for Energy Research and Training, Ahmadu Bello University, Zaria (Nigeria); Nuclear Engineering Teaching Laboratory, University of Texas at Austin, Austin, TX 78758 (United States); Landsberger, S.; O' Kelly, D.J.; Braisted, J. [Nuclear Engineering Teaching Laboratory, University of Texas at Austin, Austin, TX 78758 (United States); Gabdo, H. [Physics Department, Federal College of Education, Yola (Nigeria); Ewa, I.O.B.; Umar, I.M.; Funtua, I.I. [Reactor Engineering Section, Centre for Energy Research and Training, Ahmadu Bello University, Zaria (Nigeria)

    2010-10-15

    We used in this study Compton suppression method and epithermal neutron activation analysis to determine the concentration of nutrients and heavy metals in Nigerian food and beverages. The work was performed at the University of Texas TRIGA Reactor by short, medium, and long irradiation protocols, using thermal flux of 1.4x10{sup 12} n cm{sup -2} s{sup -1} and epithermal flux of 1.4x10{sup 11} n cm{sup -2} s{sup -1}. Application of Compton suppression method has reduced interferences from Compton scattered photons thereby allowing easy evaluation of Na, Cl, Ca, Cu, Mn, Mg, Co, Cr, Rb, Fe, and Se. The epithermal NAA method has enabled determination of Cd, As, Ba, Sr, Br, I, and V with little turn-around time. Quality Control and Quality Assurance of the method was tested by analyzing four Standard Reference Materials (non-fat powdered milk, apple leaves, citrus leaves, and peach leaves) obtained from National Institute for Standards and Technology. Our results show that sorghum, millet, and maize have high values of Zn, Mn, Fe, low values of Cd, As, and Se. Powdered milks, rice, beans, and soybeans were found to have moderate amounts of all the elements. Tobacco recorded high content of Cd, Mn, and As, whereas tea, tsobo leaves, Baobab leaves, and okro seed have more As values than others. However, biscuits, macaroni, spaghetti, and noodles show lower concentrations of all the elements. The distribution of these nutrients and heavy metals in these food and beverages shows the need to fortify biscuits and pastas with micro and macro-nutrients and reduce the use of tobacco, tea, tsobo leaves, Baobab leaves, and Okro seed to avoid intake of heavy elements.

  17. Compton suppression method and epithermal NAA in the determination of nutrients and heavy metals in Nigerian food and beverages.

    Science.gov (United States)

    Ahmed, Y A; Landsberger, S; O'Kelly, D J; Braisted, J; Gabdo, H; Ewa, I O B; Umar, I M; Funtua, I I

    2010-10-01

    We used in this study Compton suppression method and epithermal neutron activation analysis to determine the concentration of nutrients and heavy metals in Nigerian food and beverages. The work was performed at the University of Texas TRIGA Reactor by short, medium, and long irradiation protocols, using thermal flux of 1.4x10(12)n cm(-2)s(-1) and epithermal flux of 1.4x10(11)n cm(-2)s(-1). Application of Compton suppression method has reduced interferences from Compton scattered photons thereby allowing easy evaluation of Na, Cl, Ca, Cu, Mn, Mg, Co, Cr, Rb, Fe, and Se. The epithermal NAA method has enabled determination of Cd, As, Ba, Sr, Br, I, and V with little turn-around time. Quality Control and Quality Assurance of the method was tested by analyzing four Standard Reference Materials (non-fat powdered milk, apple leaves, citrus leaves, and peach leaves) obtained from National Institute for Standards and Technology. Our results show that sorghum, millet, and maize have high values of Zn, Mn, Fe, low values of Cd, As, and Se. Powdered milks, rice, beans, and soybeans were found to have moderate amounts of all the elements. Tobacco recorded high content of Cd, Mn, and As, whereas tea, tsobo leaves, Baobab leaves, and okro seed have more As values than others. However, biscuits, macaroni, spaghetti, and noodles show lower concentrations of all the elements. The distribution of these nutrients and heavy metals in these food and beverages shows the need to fortify biscuits and pastas with micro and macro-nutrients and reduce the use of tobacco, tea, tsobo leaves, Baobab leaves, and Okro seed to avoid intake of heavy elements. Copyright 2010 Elsevier Ltd. All rights reserved.

  18. Neutron and gamma-ray spectra of {sup 239}PuBe and {sup 241}AmBe

    Energy Technology Data Exchange (ETDEWEB)

    Vega-Carrillo, H.R. E-mail: rvega@cantera.reduaz.mx; Manzanares-Acuna, Eduardo; Becerra-Ferreiro, A.M.; Carrillo-Nunez, Aureliano

    2002-08-01

    Neutron and gamma-ray spectra of {sup 239}PuBe and {sup 241}AmBe were measured and their dosimetric features were calculated. Neutron spectra were measured using a multisphere neutron spectrometer with a {sup 6}LiI(Eu) scintillator. The {sup 239}PuBe neutron spectrum was measured in an open environment, while the {sup 241}AmBe neutron spectrum was measured in a closed environment. Gamma-ray spectra were measured using a NaI(Tl) scintillator using the same experimental conditions for both sources. The effect of measuring conditions for the {sup 241}AmBe neutron spectrum indicates the presence of epithermal and thermal neutrons. The low-resolution neutron spectra obtained with the multisphere spectrometer allows one to calculate the dosimetric features of neutron sources. At 100 cm both sources produce approximately the same count rate as that of the 4.4 MeV gamma-ray per unit of alpha emitter activity.

  19. Neutron capture cross section standards for BNL 325, Fourth Edition

    International Nuclear Information System (INIS)

    Holden, N.E.

    1981-01-01

    This report evaluates the experimental data and recommends values for the thermal neutron cross sections and resonance integrals for the neutron capture reactions: 55 Mn(n,γ), 59 Co(n,γ) and 197 Au(n,γ). The failure of lithium and boron as standards due to the natural variation of the absorption cross sections of these elements is discussed. The Westcott convention, which describes the neutron spectrum as a thermal Maxwellian distribution with an epithermal component, is also discussed

  20. Development of high-intensity D-D and D-T neutron sources and neutron filters for medical and industrial applications

    International Nuclear Information System (INIS)

    Verbeke, J.M.

    2000-01-01

    This thesis consists of three main parts. The first one relates to boron neutron capture therapy. It summarizes the guidelines obtained by numerical simulations for the treatment of shallow and deep-seated brain tumors, as well as the results on the design of beam-shaping assemblies to moderate D-D and D-T neutrons to epithermal energies. The second part is about boron neutron capture synovectomy for the treatment of rheumatoid arthritis. Optimal neutron energy for treatment and beam-shaping assembly designs are summarized in this section. The last part is on the development of the sealed neutron generator, including experimental results on the prototype ion source and the prototype accelerator column

  1. Liquid Li based neutron source for BNCT and science application

    International Nuclear Information System (INIS)

    Horiike, H.; Murata, I.; Iida, T.; Yoshihashi, S.; Hoashi, E.; Kato, I.; Hashimoto, N.; Kuri, S.; Oshiro, S.

    2015-01-01

    Liquid lithium (Li) is a candidate material for a target of intense neutron source, heat transfer medium in space engines and charges stripper. For a medical application of BNCT, epithermal neutrons with least energetic neutrons and γ-ray are required so as to avoid unnecessary doses to a patient. This is enabled by lithium target irradiated by protons at 2.5 MeV range, with utilizing the threshold reaction of "7Li(p,n)"7Be at 1.88 MeV. In the system, protons at 2.5 MeV penetrate into Li layer by 0.25 mm with dissipating heat load near the surface. To handle it, thin film flow of high velocity is important for stable operation. For the proton accelerator, electrostatic type of the Schnkel or the tandem is planned to be employed. Neutrons generated at 0.6 MeV are gently moderated to epithermal energy while suppressing accompanying γ-ray minimum by the dedicated moderator assembly. - Highlights: • Liquid lithium (Li) is a candidate material for a target of intense neutron source. • An accelerator based neutron source with p-liquid Li target for boron neutron capture therapy is under development in Osaka University, Japan. • In our system, the harmful radiation dose due to rays and fast neutrons will be suppressed very low. • The system performance are very promising as a state of art cancer treatment system. • The project is planned as a joint undertaking between industries and Osaka University.

  2. Atmospheric Deposition of Heavy Metals in Serbia Studied by Moss Biomonitoring, Neutron Activation Analysis and GIS Technology

    CERN Document Server

    Frontasyeva, M V; Kumar, M; Matavuly, M; Pavlov, S S; Radnovic, D; Steinnes, E

    2002-01-01

    The results of a pilot study on atmospheric deposition of heavy metals and other trace elements using the moss biomonitoring technique in the northern part of Serbia and some areas of Bosnia are presented. Samples of Hypnum cupressiforme along with some other moss types were collected at 92 sites during the summer of 2000. A total of 44 elements were determined by instrumental neutron activation analysis using epithermal neutrons. The observed levels of Cu, Zn, As, Ag, Cd, In, Sb, etc. in the area surrounding the town of Bor (Serbia) are comparable to those reported from similar industrial areas in other countries such as the Copper Basin in Poland and the South Urals of Russia. In the same region the maximum Se and Mo concentrations are the highest ever recorded in biomonitoring studies using mosses. High median concentrations of Fe and Ni in Serbian mosses are associated with a crustal component as apparent from factor analysis of the moss data. This component could be a result of windblown soil dust (most ...

  3. TREAT neutron-radiography facility

    International Nuclear Information System (INIS)

    Harrison, L.J.

    1981-01-01

    The TREAT reactor was built as a transient irradiation test reactor. By taking advantage of built-in system features, it was possible to add a neutron-radiography facility. This facility has been used over the years to radiograph a wide variety and large number of preirradiated fuel pins in many different configurations. Eight different specimen handling casks weighing up to 54.4 t (60 T) can be accommodated. Thermal, epithermal, and track-etch radiographs have been taken. Neutron-radiography service can be provided for specimens from other reactor facilities, and the capacity for storing preirradiated specimens also exists

  4. [A clinical trial of neutron capture therapy for brain tumors

    International Nuclear Information System (INIS)

    Zamenhof, R.G.

    1989-01-01

    This report describes accomplishments by this laboratory concerning development of high-resolution alpha-autoradiography design of an optimized epithermal neutron beam dosimetry and treatment planning Using Monte Carlo techniques development of a prompt-gamma 10 B analysis facility

  5. Spallation target-moderator-reflector studies at the Weapons Neutron Research facility

    International Nuclear Information System (INIS)

    Russell, G.J.; Gilmore, J.S.; Prael, S.D.; Robinson, H.; Howe, S.D.

    1980-01-01

    Basic neutronics data, initiated by 800-MeV proton spallation reactions, are important to spallation neutron source development and electronuclear fuel production. Angle-dependent and energy-dependent neutron production cross sections, energy-dependent and total neutron yields, thermal and epithermal neutron surface and beam fluxes, and fertile-to-fissile conversion ratios are being measured. The measurements are being done at the Weapons Neutron Research facility on a variety of targets and target-moderator-reflector configurations. The experiments are relevant to the above applications, and provide data to validate computer codes. Preliminary results are presented and compared to calculated predictions. 13 figures

  6. Determination of the sodium, aluminium, potassium, manganese, magnesium, bromine, cadmium and chlorine concentration values in the whole blood samples of human cancer using neutron activation analysis facility of the second Egyptian research reactor

    Directory of Open Access Journals (Sweden)

    N. F. Soliman

    2010-06-01

    Full Text Available Neutron activation analysis (NAA using the Second Egyptian Research Reactor (ETRR-2 has been utilized to analyze whole blood samples. The National Cancer Institute of Egypt provided us with 18 blood samples (11 breast, 2 prostate, 2 colon, 1 pancreatic, 1 ovarian and a random sample of normal person to estimate the concentration values of Sodium, Aluminium, Potassium, Manganese, Magnesium, Bromine, Chlorine. The pneumatic irradiation rabbit system (PIRS built in the vertical thermal column of the ETRR-2 reactor is used for short time irradiation at constant power. Elemental concentrations were estimated from measurements of the gamma-ray spectra of the product short lived isotopes in the samples. The calculated thermal to epithermal neutron flux ratio was found to be 196 at irradiation position. The tabulated concentrations were calculated by using k0-neutron activation analysis (k0NAA standardization method.

  7. Determination of the f and alpha parameters in the neutron multiplier CS-ISCTN

    International Nuclear Information System (INIS)

    Hernandez, O.; Ixquiac, M.; Contreras, R.; Herrera, E.; Diaz, O.; Lopez, R.; Alvarez, P.; Manso, M.V.; Padron, G.; D Alessandro, K.

    1997-01-01

    The values of the f and alpha parameters are determined in the irradiation position of the neutron multiplier CS-ISCTN, with the aim to show the possibility to applied the parametric neutron activation analysis. The more used conventions to calculate the reaction rate; Hogdhal, Modified Stoughton-Halpering and Modified Wescott, the last is presents with some new variations. This comparison is combined with R-Cd multi monitors method, Cd-Cover Multi monitor Methods and a new method introduced in the present paper to reduce the errors in the alpha parameter determination named Minimal Difference Method. This last method show better results, according to the epithermal hardeners of the CS-ISCT

  8. Critical elements in Carlin, epithermal, and orogenic gold deposits

    Science.gov (United States)

    Goldfarb, Richard J.; Hofstra, Albert H.; Simmons, Stuart F.

    2016-01-01

    Carlin, epithermal, and orogenic gold deposits, today mined almost exclusively for their gold content, have similar suites of anomalous trace elements that reflect similar low-salinity ore fluids and thermal conditions of metal transport and deposition. Many of these trace elements are commonly referred to as critical or near-critical elements or metals and have been locally recovered, although typically in small amounts, by historic mining activities. These elements include As, Bi, Hg, In, Sb, Se, Te, Tl, and W. Most of these elements are now solely recovered as by-products from the milling of large-tonnage, base metal-rich ore deposits, such as porphyry and volcanogenic massive sulfide deposits.A combination of dominance of the world market by a single country for a single commodity and a growing demand for many of the critical to near-critical elements could lead to future recovery of such elements from select epithermal, orogenic, or Carlin-type gold deposits. Antimony continues to be recovered from some orogenic gold deposits and tellurium could potentially be a primary commodity from some such deposits. Tellurium and indium in sphalerite-rich ores have been recovered in the past and could be future commodities recovered from epithermal ores. Carlin-type gold deposits in Nevada are enriched in and may be a future source for As, Hg, Sb, and/or Tl. Some of the Devonian carbonaceous host rocks in the Carlin districts are sufficiently enriched in many trace elements, including Hg, Se, and V, such that they also could become resources. Thallium may be locally enriched to economic levels in Carlin-type deposits and it has been produced from Carlin-like deposits elsewhere in the world (e.g., Alsar, southern Macedonia; Lanmuchang, Guizhou province, China). Mercury continues to be recovered from shallow-level epithermal deposits, as well as a by-product of many Carlin-type deposits where refractory ore is roasted to oxidize carbon and pyrite, and mercury is then

  9. High yield neutron generators using the DD reaction

    Energy Technology Data Exchange (ETDEWEB)

    Vainionpaa, J. H.; Harris, J. L.; Piestrup, M. A.; Gary, C. K.; Williams, D. L.; Apodaca, M. D.; Cremer, J. T. [Adelphi technology, 2003 E. Bayshore Rd. 94061, Redwood City, CA (United States); Ji, Qing; Ludewigt, B. A. [Lawrence Berkeley National Lab, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Jones, G. [G and J Enterprise, 1258 Quary Ln, Suite F, Pleasanton California 94566 (United States)

    2013-04-19

    A product line of high yield neutron generators has been developed at Adelphi technology inc. The generators use the D-D fusion reaction and are driven by an ion beam supplied by a microwave ion source. Yields of up to 5 Multiplication-Sign 10{sup 9} n/s have been achieved, which are comparable to those obtained using the more efficient D-T reaction. The microwave-driven plasma uses the electron cyclotron resonance (ECR) to produce a high plasma density for high current and high atomic ion species. These generators have an actively pumped vacuum system that allows operation at reduced pressure in the target chamber, increasing the overall system reliability. Since no radioactive tritium is used, the generators can be easily serviced, and components can be easily replaced, providing essentially an unlimited lifetime. Fast neutron source size can be adjusted by selecting the aperture and target geometries according to customer specifications. Pulsed and continuous operation has been demonstrated. Minimum pulse lengths of 50 {mu}s have been achieved. Since the generators are easily serviceable, they offer a long lifetime neutron generator for laboratories and commercial systems requiring continuous operation. Several of the generators have been enclosed in radiation shielding/moderator structures designed for customer specifications. These generators have been proven to be useful for prompt gamma neutron activation analysis (PGNAA), neutron activation analysis (NAA) and fast neutron radiography. Thus these generators make excellent fast, epithermal and thermal neutron sources for laboratories and industrial applications that require neutrons with safe operation, small footprint, low cost and small regulatory burden.

  10. Investigation on the neutron beam characteristics for boron neutron capture therapy with 3D and 2D transport calculations

    International Nuclear Information System (INIS)

    Kodeli, I.; Diop, C.M.; Nimal, J.C.

    1994-01-01

    In the framework of future Boron Neutron Capture Therapy (BNCT) experiments, where cells and animals irradiations are planned at the research reactor of Strasbourg University, the feasibility to obtain a suitable epithermal neutron beam is investigated. The neutron fluence and spectra calculations in the reactor are performed using the 3D Monte Carlo code TRIPOLI-3 and the 2D SN code TWODANT. The preliminary analysis of Al 2 O 3 and Al-Al 2 O 3 filters configurations are carried out in an attempt to optimize the flux characteristics in the beam tube facility. 7 figs., 7 refs

  11. High conduction neutron absorber to simulate fast reactor environment in an existing test reactor

    Energy Technology Data Exchange (ETDEWEB)

    Donna Post Guillen; Larry R. Greenwood; James R. Parry

    2014-06-22

    A new metal matrix composite material has been developed to serve as a thermal neutron absorber for testing fast reactor fuels and materials in an existing pressurized water reactor. The performance of this material was evaluated by placing neutron fluence monitors within shrouded and unshrouded holders and irradiating for up to four cycles. The monitor wires were analyzed by gamma and X-ray spectrometry to determine the activities of the activation products. Adjusted neutron fluences were calculated and grouped into three bins—thermal, epithermal, and fast—to evaluate the spectral shift created by the new material. A comparison of shrouded and unshrouded fluence monitors shows a thermal fluence decrease of ~11 % for the shielded monitors. Radioisotope activity and mass for each of the major activation products is given to provide insight into the evolution of thermal absorption cross-section during irradiation. The thermal neutron absorption capability of the composite material appears to diminish at total neutron fluence levels of ~8 × 1025 n/m2. Calculated values for dpa in excess of 2.0 were obtained for two common structural materials (iron and nickel) of interest for future fast flux experiments.

  12. Design of hyper-thermal neutron irradiation fields for neutron capture therapy in KUR-heavy water neutron irradiation facility. Mounting of hyper-thermal neutron converter in therapeutic collimator

    International Nuclear Information System (INIS)

    Sakurai, Y.; Kobayashi, T.

    2001-01-01

    Neutron capture therapy (NCP) using thermal neutron needs to improve of depth dose distribution in a living body. Epi-thermal neutron following moderation of fast neutron is usually used for improving of the depth dose distribution. The moderation method of fast neutron, however, gets mixed some of high energy neutron which give some of serious effects to a living body, and involves the difficulty for collimation of thermal neutron to the diseased part. Hyper-thermal neutrons, which are in an energy range of 0.1-3 eV at high temperature side of thermal neutron, are under consideration for application to the NCP. The hyper-thermal neutrons can be produced by up-scattering of thermal neutron in a high temperature material. Fast neutron components in collimator for the NCP reduce on application of the up-scattering method. Graphite at high temperature (>1000k) is used as a hyper-thermal neutron converter. The hyper-thermal neutron converter is planted to mount on therapeutic collimator which is located at the nearest side of patient for the NCP. Total neutron flux, ratio of hyper-thermal neutron to total neutron, and ratio of gamma-ray dose to neutron flux are calculated as a function of thickness of the graphite converter using monte carlo code MCNP-V4B. (M. Suetake)

  13. Use of Germanium as comparator and integral monitor of neutron flux in activation analysis; Utilizacion del germanio como comparador y monitor integral de flujo neutronico en analisis por activacion

    Energy Technology Data Exchange (ETDEWEB)

    Furnari, Juan C.; Cohen, Isaac M. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Centro Atomico Ezeiza; Arribere, Maria A.; Kestelman, Abraham J. [Comision Nacional de Energia Atomica, San Carlos de Bariloche (Argentina). Centro Atomico Bariloche

    1997-10-01

    The possibility of using germanium as monitor of the thermal and epithermal components of the neutron flux, and comparator in parametric activation analysis, is discussed. The advantages and drawbacks associated to the use of this element are commented on, and the comparison with zirconium, in terms of the determination relative error, is performed. The utilisation of germanium as integral flux monitor, including the fast component of the neutron spectrum, is also discussed. Data corresponding to measurements of k{sub 0} factor for the most relevant gamma transitions from Ge-75 and Be-77 are presented, as well as the results of the reference material analysis, employing germanium as flux monitor and comparator in a simultaneous way. (author). 8 refs., 3 figs., 2 tabs.

  14. Validation of dose planning calculations for boron neutron capture therapy using cylindrical and anthropomorphic phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Koivunoro, Hanna; Seppaelae, Tiina; Uusi-Simola, Jouni; Merimaa, Katja; Savolainen, Sauli [Department of Physics, POB 64, FI-00014 University of Helsinki (Finland); Kotiluoto, Petri; Seren, Tom; Auterinen, Iiro [VTT Technical Research Centre of Finland, Espoo, POB 1000, FI-02044 VTT (Finland); Kortesniemi, Mika, E-mail: hanna.koivunoro@helsinki.f [HUS Helsinki Medical Imaging Center, University of Helsinki, POB 340, FI-00029 HUS (Finland)

    2010-06-21

    In this paper, the accuracy of dose planning calculations for boron neutron capture therapy (BNCT) of brain and head and neck cancer was studied at the FiR 1 epithermal neutron beam. A cylindrical water phantom and an anthropomorphic head phantom were applied with two beam aperture-to-surface distances (ASD). The calculations using the simulation environment for radiation application (SERA) treatment planning system were compared to neutron activation measurements with Au and Mn foils, photon dose measurements with an ionization chamber and the reference simulations with the MCNP5 code. Photon dose calculations using SERA differ from the ionization chamber measurements by 2-13% (disagreement increased along the depth in the phantom), but are in agreement with the MCNP5 calculations within 2%. The {sup 55}Mn(n,{gamma}) and {sup 197}Au(n,{gamma}) reaction rates calculated using SERA agree within 10% and 8%, respectively, with the measurements and within 5% with the MCNP5 calculations at depths >0.5 cm from the phantom surface. The {sup 55}Mn(n,{gamma}) reaction rate represents the nitrogen and boron depth dose within 1%. Discrepancy in the SERA fast neutron dose calculation (of up to 37%) is corrected if the biased fast neutron dose calculation option is not applied. Reduced voxel cell size ({<=}0.5 cm) improves the SERA calculation accuracy on the phantom surface. Despite the slight overestimation of the epithermal neutrons and underestimation of the thermal neutrons in the beam model, neutron calculation accuracy with the SERA system is sufficient for reliable BNCT treatment planning with the two studied treatment distances. The discrepancy between measured and calculated photon dose remains unsatisfactorily high for depths >6 cm from the phantom surface. Increasing discrepancy along the phantom depth is expected to be caused by the inaccurately determined effective point of the ionization chamber.

  15. An accelerator neutron source for BNCT. Technical progress report, 1 June 1993--31 May 1994

    International Nuclear Information System (INIS)

    Blue, T.E.; Vafai, K.

    1994-02-01

    This is the progress report for the project entitled, ''An Accelerator Neutron Source for BNCT.'' The progress report is for the period from July 1, 1993 to date. The overall objective of our research project is to develop an Accelerator Epithermal Neutron Irradiation Facility (AENIF) for Boron Neutron Capture Therapy (BNCT). The AENIF consists of a 2.5 MeV high current proton accelerator, a lithium target to produce source neutrons, and a moderator/reflector assembly to obtain from the energetic source neutrons an epithermal neutron field suitable for BNCT treatments. Our project goals are to develop the non-accelerator components of the AENIF, and to specifically include in our development: (1) design, numerical simulation, and experimental verification of a target assembly which is capable of removing 75 kW of beam power; (2) re-optimization of the moderator assembly design based on in-phantom dose assessments using neutron spectra calculated in phantom and an energy-dependent neutron Relative Biological Effectiveness (RBE); (3) construction of a prototype moderator assembly and confirmation of its design by measurements; (4) design of the shielding of the accelerator and treatment rooms for an AENIF; and (5) design of a high energy beam transport system which is compatible with the shielding design and the thermal-hydraulic design

  16. Evaluation of radioactivity in the bodies of mice induced by neutron exposure from an epi-thermal neutron source of an accelerator-based boron neutron capture therapy system

    Science.gov (United States)

    NAKAMURA, Satoshi; IMAMICHI, Shoji; MASUMOTO, Kazuyoshi; ITO, Masashi; WAKITA, Akihisa; OKAMOTO, Hiroyuki; NISHIOKA, Shie; IIJIMA, Kotaro; KOBAYASHI, Kazuma; ABE, Yoshihisa; IGAKI, Hiroshi; KURITA, Kazuyoshi; NISHIO, Teiji; MASUTANI, Mitsuko; ITAMI, Jun

    2017-01-01

    This study aimed to evaluate the residual radioactivity in mice induced by neutron irradiation with an accelerator-based boron neutron capture therapy (BNCT) system using a solid Li target. The radionuclides and their activities were evaluated using a high-purity germanium (HP-Ge) detector. The saturated radioactivity of the irradiated mouse was estimated to assess the radiation protection needs for using the accelerator-based BNCT system. 24Na, 38Cl, 80mBr, 82Br, 56Mn, and 42K were identified, and their saturated radioactivities were (1.4 ± 0.1) × 102, (2.2 ± 0.1) × 101, (3.4 ± 0.4) × 102, 2.8 ± 0.1, 8.0 ± 0.1, and (3.8 ± 0.1) × 101 Bq/g/mA, respectively. The 24Na activation rate at a given neutron fluence was found to be consistent with the value reported from nuclear-reactor-based BNCT experiments. The induced activity of each nuclide can be estimated by entering the saturated activity of each nuclide, sample mass, irradiation time, and proton current into the derived activation equation in our accelerator-based BNCT system. PMID:29225308

  17. Personnel neutron dosimetry using TLD elements at PNC

    International Nuclear Information System (INIS)

    Ishiguro, Hideharu

    1985-01-01

    The evaluation method of neutron dose equivalent was studied on the basis of the albedo type neutron dosimetory to design the personnel dosimeter. The dosimeter was composed of three 6 Li 2 10 B 4 O 7 (Cu) TL elements and one 7 Li 2 11 B 4 O 7 (Cu) element. The equations for assessing thermal, epithermal and fast neutron dose equivalents were derived by 252 Cf, 241 Am-Be and PuO 2 neutron sources. The minimum detectable amount of 6 Li 2 10 B 4 O 7 (Cu) element to thermal neutron was 0.02 m rem. The neutron dose equivalent and the gamma one were evaluated separately within about 20 % error in the mixed radiation field. (author)

  18. Method and apparatus for determination of temperature, neutron absorption cross section and neutron moderating power

    Science.gov (United States)

    Vagelatos, Nicholas; Steinman, Donald K.; John, Joseph; Young, Jack C.

    1981-01-01

    A nuclear method and apparatus determines the temperature of a medium by injecting fast neutrons into the medium and detecting returning slow neutrons in three first energy ranges by producing three respective detection signals. The detection signals are combined to produce three derived indicia each systematically related to the population of slow neutrons returning from the medium in a respective one of three second energy ranges, specifically exclusively epithermal neutrons, exclusively substantially all thermal neutrons and exclusively a portion of the thermal neutron spectrum. The derived indicia are compared with calibration indicia similarly systematically related to the population of slow neutrons in the same three second energy ranges returning from similarly irradiated calibration media for which the relationships temperature, neutron absorption cross section and neutron moderating power to such calibration indicia are known. The comparison indicates the temperature at which the calibration indicia correspond to the derived indicia and consequently the temperature of the medium. The neutron absorption cross section and moderating power of the medium can be identified at the same time.

  19. A new neutron spectrometry system for in-core and out-core application at WWER

    International Nuclear Information System (INIS)

    Mehner, H.C.; Boehmer, B.; Hagemann, U.; Nagel, S.; Schoene, M.; Stephan, I.

    1985-01-01

    An automated measuring system based on a newly-developed multi-component wire activation detector (MWAD) is presented which has been applied for neutron spectrometry inside WWER. The MWAD consisting of Au, Mn, Mo, Ni, and W is designed to determine the neutron spectrum in the thermal, epithermal and fast energy region by a single gamma-ray spectrum measurement. Investigations were carried out within an ordinary fuel assembly of the Greifswald NPS (WWER-440) as well as in experimental fuel assembly of the Rheinsberg NPS (WWER-70). The evaluation of the measurements was done with the newly-developed adjustment code COSA based on the generalized least square method. (author)

  20. Study on the determination of palladium in biological samples by the method of neutron activation analysis

    International Nuclear Information System (INIS)

    Cavalcante, Cassio Queiroz

    2007-01-01

    Palladium is one of platinum group elements present in the nature at very low concentrations. However with the use of this element in the automobile catalyzers Pd became a new pollutant. Besides, Pd has been studied in the preparation of new antitumour drugs. Consequently, there is a need to determine Pd concentrations in biological and environmental samples. This study presents palladium results obtained in the analysis of biological samples and reference materials using instrumental thermal and epithermal neutron activation analysis (INAA and ENAA). The solvent extraction and solid phase extraction separation methods were also applied before ENAA. The samples analyzed in this study were, reference material BCR 723 - Palladium, Platinum and Rhodium in road dust, CCQM-P63 automotive catalyst material of the Proficiency Test and bovine tissue samples containing palladium prepared in the laboratory. Samples and palladium synthetic standard were irradiated at the IEA-R1 nuclear research reactor under thermal neutron flux of about 4 x 10 12 n cm-2 s-1, during a period of 4 and 16 h for INAA and ENAA, respectively. The induced gamma activity of 109 Pd to the sample and standard was measured using a hyper pure Ge detector coupled to a gamma ray spectrometer. The palladium concentration was calculated by comparative method. The gamma ray energy of 109 Pd radioisotope measured was of 88.0 keV, located in a spectrum region of low energy where occurs the interference of X rays, 'Bremsstrahlung' radiations, as well as Compton effect of 24 Na. The pre-separation of palladium from interfering elements by solvent extraction was performed using dimethylglyoxime complexant and chloroform as diluent. In the case of the pre separation procedure using solid reversed phase column, the palladium was retained using N,N-diethyl-N'-benzoyl thiourea complexant and eluted using ethanol. Aliquots of the resulting solutions from the pre-separations, free of interfering elements, were

  1. Characteristics of thermal neutron calibration fields using a graphite pile

    International Nuclear Information System (INIS)

    Uchita, Yoshiaki; Saegusa, Jun; Kajimoto, Yoichi; Tanimura, Yoshihiko; Shimizu, Shigeru; Yoshizawa, Michio

    2005-03-01

    The Facility of Radiation Standards of Japan Atomic Energy Research Institute is equipped with thermal neutron fields for calibrating area and personal neutron dosemeters. The fields use moderated neutrons leaked from a graphite pile in which radionuclide sources are placed. In January 2003, we have renewed the pile with some modifications in its size. In accordance with the renewal, we measured and calculated thermal neutron fluence rates, neutron energy distributions and angular distributions of the fields. The thermal neutron fluence rates of the ''inside-pile fields'' and the outside-pile fields'' were determined by the gold foil activation method. The neutron energy distributions of the outside-pile fields were also measured with the Bonner multi-sphere spectrometer system. The contributions of epithermal and fast neutrons to the total dose-equivalents were 9% in the southern outside-pile field and 12% in the western outside-pile field. The personal dose-equivalents, H p,slab (10, α), in the outside-pile fields are evaluated by considering the calculated angular distributions of incoming neutrons. The H p,slab (10, α) was found to be about 40% higher than the value in assuming the unidirectional neutron between the pile and the test point. (author)

  2. Application of activation methods on the Dubna experimental transmutation set-ups.

    Science.gov (United States)

    Stoulos, S; Fragopoulou, M; Adloff, J C; Debeauvais, M; Brandt, R; Westmeier, W; Krivopustov, M; Sosnin, A; Papastefanou, C; Zamani, M; Manolopoulou, M

    2003-02-01

    High spallation neutron fluxes were produced by irradiating massive heavy targets with proton beams in the GeV range. The experiments were performed at the Dubna High Energy Laboratory using the nuclotron accelerator. Two different experimental set-ups were used to produce neutron spectra convenient for transmutation of radioactive waste by (n,x) reactions. By a theoretical analysis neutron spectra can be reproduced from activation measurements. Thermal-epithermal and fast-super-fast neutron fluxes were estimated using the 197Au, 238U (n,gamma) and (n,2n) reactions, respectively. Depleted uranium transmutation rates were also studied in both experiments.

  3. A Selective Neutron Detector in the keV Region Utilizing the {sup 19}F (n, gamma) {sup 20}F Reaction

    Energy Technology Data Exchange (ETDEWEB)

    Konijn, J

    1963-05-15

    The Research Swimming-Pool Reactor R2-0 at Studsvik has been used to investigate some resonance and threshold reactions for neutron flux measurements. This reactor, equipped with MTR type fuel elements, has a maximum neutron flux of about 10{sup 12} n/cm{sup 2}/sec, giving a thermal output of 100 kW. A pneumatic rabbit was constructed to bring the samples in activation position, in which there was 15 cm H{sub 2}O and 1.2 cm Al between reactor and foil. A covering, containing 1.22 g {sup 10}B/cm{sup 2} was pushed over the cadmium-covered Al tube of the rabbit. The activation of the foil was measured with a Nal(Tl)-scintillation spectrometer. From the gamma ray spectrum, recorded on a 256 channel pulse height analyzer, the epithermal neutron flux per unit of In E interval was calculated. The activation cross section for {sup 19}F (n, {gamma}) {sup 20}F in the {sup 10}B-covering was computed to be 16 mb, and about 60 % of the induced activity is due to neutrons in the energy range of 20-70 keV. The experimental results were compared with those obtained from the more known resonance reactions {sup 63}Cu (n, {gamma}) {sup 64}Cu and {sup 27}Al (n, {gamma}) {sup 28}Al. The epithermal neutron flux experiments are in good agreement with each other. The fast neutron flux measurements were carried out with the following threshold detectors: {sup 197}Au (n, n') {sup 197m}Au, {sup 58}Ni (n, p) {sup 58}Co, {sup 27}Al (n, p) {sup 27}Mg and {sup 19}F (n, p) {sup 19}O. From these experiments the ratio of {phi}{sub epi}/{phi}{sub fiss} =0.045 {+-} 0.010 is determined at the activation position. The half-life of {sup 197}Au m was determined to 7.35 {+-} 0.25 sec.

  4. About neutron capture therapy method development at WWR-SM reactor in institute of Nuclear Physics of Uzbekistan Academy of Sciences

    International Nuclear Information System (INIS)

    Abdullaeva, G.A.; Baytelesov, S.A.; Dosimbaev, A.A.; Koblik, Yu.N.; Gritsay, O.O.

    2006-01-01

    Full text: Neutron capture therapy (NCT) is developing method of swellings treatment, on which specialists set one's serious hopes, as at its realization the practical possibilities of the effect on any swellings open. The essence of method is simple and lies in the fact that to the swelling enter preparation containing boron or gadolinium, which one have a large capture cross-section of the thermal and slow neutrons. Then the swelling is irradiated once with the slow (epithermal) neutron beam with fluency about 10 9 neutrons /sm 2 s for a short time and single. As a result of thermal neutrons capture by the boron (or gadolinium) nuclei secondary radiation which affecting swelling cells is emitted. NCT of oncologic diseases makes the specific demands to physical parameters of neutron beams. Now research reactors are often used for NCT. However, research reactor WWR-SM (INP, Uzbekistan AS, Tashkent) doesn't provide with the epithermal neutron beams and to develop this technique the reactor, first of all, needs for obtaining the epithermal neutron beams with energy spectrum in range from 1 eV up to 10 keV and with intensity ∼ 10 9 neutron /sm 2 s. Practically it is connected with upgrade of at least one of existed reactor channels, namely with equipping with the special equipment (filters), forming from the reactor spectrum the beam of necessary energy neutrons. It requires realization of preliminary model calculations, including calculations of capture cross-sections, of filters types and their geometrical parameters on the basis of optimal selected materials. Such calculations, as a rule, are carried out on the basis of Monte-Carlo method and designed software for calculation of nuclear reactor physical and technical characteristics [1]. In this work the calculation results of devices variants and problems discussion, related with possibility of WWR-SM reactor using for NCT are presented. (author)

  5. An optimum source neutron spectrum and holder shape for extra-corporal treatment of liver cancer by BNCT

    International Nuclear Information System (INIS)

    Nievaart, Sander; Moss, Ray; Sauerwein, Wolfgang; Malago, Massimo; Kloosterman, Jan Leen; Hagen, Tim van der; Dam, Hugo van

    2006-01-01

    In extra-corporal treatment of liver cancer by BNCT, it is desired to have an as homogeneous as possible thermal neutron field throughout the organ. Previous work has shown that when using an epithermal neutron beam, the shape of the holder in which the liver is placed is the critical factor. This study develops the notion further as to what is the optimum neutron spectrum to perform such treatments. In the design calculations, when using Monte Carlo techniques, it is shown that when the expected contributions of the source neutrons in every part of the liver is calculated, a linear optimization scheme such as the Simplex method results in a mix of thermal and epithermal source neutrons to get the highest homogeneity for the thermal neutron field. This optimisation method is demonstrated in 3 holder shapes: cuboid, cylindrical and spherical with each 3 volumes of 2, 4 and 6 litres. A 10 cm thick cuboid model, irradiated from both sides gives the highest homogeneity. The spherical (rotating) holder has the lowest homogeneity but the highest contribution of every source neutron to the thermal neutrons in the liver. This can be advantageous when using a relatively small sized neutron beam with a low strength. (author)

  6. Measurement of thermal neutron cross-section and resonance integral for the 165Ho(n,γ) 166gHo reaction using electron linac-based neutron source

    Science.gov (United States)

    Nguyen, Van Do; Pham, Duc Khue; Kim, Tien Thanh; Kim, Guinyun; Lee, Manwoo; Kim, Kyung Sook; Kang, Heung-Sik; Cho, Moo-Hyun; Ko, In Soo; Namkung, Won

    2011-01-01

    The thermal neutron cross-section and the resonance integral of the 165Ho(n,γ) 166gHo reaction have been measured by the activation method using a 197Au(n,γ) 198Au monitor reaction as a single comparator. The high-purity natural Ho and Au foils with and without a cadmium shield case of 0.5 mm thickness were irradiated in a neutron field of the Pohang neutron facility. The induced activities in the activated foils were measured with a calibrated p-type high-purity Ge detector. The correction factors for the γ-ray attenuation ( Fg), the thermal neutron self-shielding ( Gth), the resonance neutron self-shielding ( Gepi) effects, and the epithermal neutron spectrum shape factor ( α) were taken into account. The thermal neutron cross-section for the 165Ho(n,γ) 166gHo reaction has been determined to be 59.7 ± 2.5 barn, relative to the reference value of 98.65 ± 0.09 barn for the 197Au(n,γ) 198Au reaction. By assuming the cadmium cut-off energy of 0.55 eV, the resonance integral for the 165Ho(n,γ) 166gHo reaction is 671 ± 47 barn, which is determined relative to the reference value of 1550 ± 28 barn for the 197Au(n,γ) 198Au reaction. The present results are, in general, good agreement with most of the previously reported data within uncertainty limits.

  7. Multielement analysis of human hair and kidney stones by instrumental neutron activation analysis with the k0-standardization method

    International Nuclear Information System (INIS)

    Abugassa, I.; Sarmani, S.B.; Samat, S.B.

    1999-01-01

    This paper focuses on the evaluation of the k 0 method of instrumental neutron activation analysis in biological materials. The method has been applied in multielement analysis of human hair standard reference materials from IAEA, No. 085, No. 086 and from NIES (National Institute for Environmental Sciences) No. 5. Hair samples from people resident in different parts of Malaysia, in addition to a sample from Japan, were analyzed. In addition, human kidney stones from members of the Malaysian population have been analyzed for minor and trace elements. More than 25 elements have been determined. The samples were irradiated in the rotary rack (Lazy Susan) at the TRIGA Mark II reactor of the Malaysian Institute for Nuclear Technology and Research (MINT). The accuracy of the method was ascertained by analysis of other reference materials, including 1573 tomato leaves and 1572 citrus leaves. In this method the deviation of the 1/E 1+α epithermal neutron flux distribution from the 1/E law (P/T ratio) for true coincidence effects of the γ-ray cascade and the HPGe detector efficiency were determined and corrected for

  8. Characterization of neutron flux spectra in the irradiation sites of a 37 GBq {sup 241}Am-Be isotopic source

    Energy Technology Data Exchange (ETDEWEB)

    Yücel, Haluk [Ankara University, Institute of Nuclear Sciences, 06100 Tandogan, Ankara (Turkey); Budak, Mustafa Guray, E-mail: mbudak@gazi.edu.tr [Gazi University, Gazi Education Faculty, 06500 Teknikokullar, Ankara (Turkey); Karadag, Mustafa [Gazi University, Gazi Education Faculty, 06500 Teknikokullar, Ankara (Turkey); Yüksel, Alptuğ Özer [Ankara University, Institute of Nuclear Sciences, 06100 Tandogan, Ankara (Turkey)

    2014-11-01

    Highlights: • An irradiation unit was installed using a 37 GBq {sup 241}Am-Be neutron source. • The source neutrons moderated by using both water and paraffin. • Irradiation unit was shielded by boron oxide and lead against neutrons and gammas. • There are two sites for irradiations, one of them has a pneumatic transfer system. • Cadmium ratio method was used for irradiation site characterization. - Abstract: For the applicability of instrumental neutron activation analysis (NAA) technique, an irradiation unit with a 37 GBq {sup 241}Am-Be neutron source was installed at Institute of Nuclear Sciences of Ankara University. Design and configuration properties of the irradiation unit are described. It has two different sample irradiation positions, one is called site #1 having a pneumatic sample transfer system and the other is site #2 having a location for manual use. In order to characterize neutron flux spectra in the irradiation sites, the measurement results were obtained for thermal (φ{sub th}) and epithermal neutron fluxes (φ{sub epi}), thermal to epithermal flux ratio (f) and epithermal spectrum shaping factors (α) by employing cadmium ratios of gold (Au) and molybdenum (Mo) monitors. The activities produced in these foils were measured by using a p-type, 44.8% relative efficiency HPGe well detector. For the measured γ-rays, self-absorption and true coincidence summing effects were taken into account. Additionally, thermal neutron self-shielding and resonance neutron self-shielding effects were taken into account in the measured results. For characterization of site #1, the required parameters were found to be φ{sub th} = (2.11 ± 0.05) × 10{sup 3} n cm{sup −2} s{sup −1}, φ{sub epi} = (3.32 ± 0.17) × 10{sup 1} n cm{sup −2} s{sup −1}, f = 63.6 ± 1.5, α = 0.045 ± 0.009, respectively. Similarly, those parameters were measured in site #2 as φ{sub th} = (1.49 ± 0.04) × 10{sup 3} n cm{sup −2} s{sup −1}, φ{sub epi} = (2.93 ± 0

  9. Overview of the Conceptual Design of the Future VENUS Neutron Imaging Beam Line at the Spallation Neutron Source

    Science.gov (United States)

    Bilheux, Hassina; Herwig, Ken; Keener, Scott; Davis, Larry

    VENUS (Versatile Neutron Imaging Beam line at the Spallation Neutron Source) will be a world-class neutron-imaging instrument that will uniquely utilize the Spallation Neutron Source (SNS) time-of-flight (TOF) capabilities to measure and characterize objects across several length scales (mm to μm). When completed, VENUS will provide academia, industry and government laboratories with the opportunity to advance scientific research in areas such as energy, materials, additive manufacturing, geosciences, transportation, engineering, plant physiology, biology, etc. It is anticipated that a good portion of the VENUS user community will have a strong engineering/industrial research focus. Installed at Beam line 10 (BL10), VENUS will be a 25-m neutron imaging facility with the capability to fully illuminate (i.e., umbra illumination) a 20 cm x 20 cm detector area. The design allows for a 28 cm x 28 cm field of view when using the penumbra to 80% of the full illumination flux. A sample position at 20 m will be implemented for magnification measurements. The optical components are comprised of a series of selected apertures, T0 and bandwidth choppers, beam scrapers, a fast shutter to limit sample activation, and flight tubes filled with Helium. Techniques such as energy selective, Bragg edge and epithermal imaging will be available at VENUS.

  10. Cadmium-Zinc-Telluride photon detector for epithermal neutron spectroscopy--pulse height response characterisation

    International Nuclear Information System (INIS)

    Tardocchi, M.; Pietropaolo, A.; Andreani, C.; Bracco, A.; D'Angelo, A.; Gorini, G.; Imberti, S.; Senesi, R.; Rhodes, N.J.; Schooneveld, E.M.

    2004-01-01

    The Resonance Detector Spectrometer was recently revised for neutron spectroscopic studies in the eV energy region. In this technique one makes use of a photon detector to record the gamma emission from analyser foils used as neutron-gamma converters. The pulse-height response of a Cadmium-Zinc-Telluride photon detector to neutron capture emission from 238 U and 197 Au analyser foils was characterised in the neutron energy range 1-200 eV. The experiment was performed on the VESUVIO spectrometer at the ISIS neutron-pulsed source. A biparametric data acquisition, specifically developed for these measurements, allowed the simultaneous measurements of both the neutron time of flight and γ pulse-height spectra. Through the analysis of the γ pulse-height spectra the main components of the signal associated with resonant and non-resonant neutron absorption were identified. It was also shown that, in principle, energy discrimination can be used to improve the signal to background ratio of the neutron time-of-flight measurement

  11. The k0-NAA Standardization Method Using an Am-Be Neutron Source

    International Nuclear Information System (INIS)

    Soliman, N.F.; Mohamed, G.Y.; Hassan, M.F.; Ali, M.A.

    2012-01-01

    Instrumental neutron activation analysis is a well established technique for the analysis of trace elements in different samples. Precise elemental concentrations of Al, Mn, Mg and Na in two unknown geological samples were determined by using the k 0 -standardization method. For such measurements two sets of standard monitors of Gold (Au), Indium (In), Tungsten (W) and Titanium (Ta) were used. One set is bare and the other is cadmium covered. These monitors were used for measuring the irradiation position factors f and α and using the cadmium ratios of the 115 In(n,γ) 116 In and 182 Ta(n,γ) 183 Ta interactions. Neutrons were obtained from CNIF 2 facility that uses an Am-Be radio-isotopic neutron source with a modification to have thermal and epi-thermal neutrons. Measurements were carried out using a gamma-ray spectrometer consisting of a hyper pure germanium detector and necessary associated electronics. The k 0 -standardization method can be used for quality control tests.

  12. Comparison of neutron activation analysis techniques for the determination of uranium concentrations in geological and environmental materials

    International Nuclear Information System (INIS)

    Landsberger, S.; Kapsimalis, R.

    2013-01-01

    We have described the determination of uranium in environmental, geological, and agricultural specimens by three different non-destructive nuclear methods. The effectiveness, as defined as the lower limits of detection in this work, of quantifying trace levels of bulk uranium in geological samples was evaluated for several common NAA techniques. These techniques include short-lived and medium-lived neutron activation analysis using thermal and epithermal neutrons; these results were compared with an assessment of Compton suppressed gamma-ray counting. A careful evaluation of three major (n,γ) reactions with chlorine, manganese and sodium that could impede determining low levels of uranium due to high Compton continuums was done. The evaluation of Compton suppressed passive gamma counting revealed that uranium concentrations below 50 mg kg −1 were not adequate to achieve good counting statistics using the 234m Pa the second daughter product of 238 U. -- Highlights: ► Determination of uranium concentrations in geological, environmental, and agricultural specimens. ► Use of several NAA and passive counting methods. ► Identified several key interferences. ► Use of Compton suppression to minimize effects of interferences

  13. Boron Neutron Capture Therapy at the TRIGA Mark II of Pavia, Italy - The BNCT of the diffuse tumours

    Energy Technology Data Exchange (ETDEWEB)

    Altieri, S.; Bortolussi, S.; Stella, S.; Bruschi, P.; Gadan, M.A. [University of Pavia (Italy); INFN - National Institute for Nuclear Physics, of Pavia (Italy)

    2008-10-29

    The selectivity based on the B distribution rather than on the irradiation field makes Boron neutron Capture Therapy (BNCT) a valid option for the treatment of the disseminated tumours. As the range of the high LET particles is shorter than a cell diameter, the normal cells around the tumour are not damaged by the reactions occurring in the tumoral cells. PAVIA 2001: first treatment of multiple hepatic metastases from colon ca by BNCT and auto-transplantation technique: TAOrMINA project. The liver was extracted after BPA infusion, irradiated in the Thermal Column of the Pavia TRIGA Mark II reactor, and re-implanted in the patient. Two patients were treated, demonstrating the feasibility of the therapy and the efficacy in destroying the tumoral nodules sparing the healthy tissues. In the last years, the possibility of applying BNCT to the lung tumours using epithermal collimated neutron beams and without explanting the organ, is being explored. The principal obtained results of the BNCT research are presented, with particular emphasis on the following aspects: a) the project of a new thermal column configuration to make the thermal neutron flux more uniform inside the explanted liver, b) the Monte Carlo study by means of the MCNP code of the thermal neutron flux distribution inside a patient's thorax irradiated with epithermal neutrons, and c) the measurement of the boron concentration in tissues by (n,{alpha}) spectroscopy and neutron autoradiography. The dose distribution in the thorax are simulated using MCNP and the anthropomorphic model ADAM. To have a good thermal flux distribution inside the lung epithermal neutrons must be used, which thermalize crossing the first tissue layers. Thermal neutrons do not penetrate and the obtained uniformity is poor. In the future, the construction of a PGNAA facility using a horizontal channel of the TRIGA Mark II is planned. With this method the B concentration can be measured also in liquid samples (blood, urine) and

  14. Neutron activation studies on JET

    International Nuclear Information System (INIS)

    Loughlin, M.J.; Forrest, R.A.; Edwards, J.E.G.

    2001-01-01

    Extensive neutron transport calculations have been performed to determine the neutron spectrum at a number of points throughout the JET torus hall. The model has been bench-marked against a set of foil activation measurements which were activated during an experimental campaign with deuterium/tritium plasmas. The model can predict the neutron activation of the foils on the torus hall walls to within a factor of three for reactions with little sensitivity to thermal neutrons. The use of scandium foils with and without a cadmium thermal neutron absorber was a useful monitor of the thermal neutron flux. Conclusions regarding the usefulness of other foils for benchmarking the calculations are also given

  15. Final design and construction issues of the TAPIRO epithermal column

    International Nuclear Information System (INIS)

    Burn, K.W.; Casalini, L.; Nava, E.; Tinti, R.; Martini, S.; Mondini, D.; Rosi, G.

    2006-01-01

    The construction of the epithermal column for clinical trials at the 5 kW fast reactor TAPIRO (ENEA, Casaccia, Italy) has been completed, the experimental bunker in the reactor hall has been designed and the beam characterisation will shortly be underway. As has been reviewed at the last two ICNCT conferences, the low power of the neuron source and the relatively distant patient position outside the reactor shield led to a column design with certain characteristics. One consequence is the employment of a collimator containing lead of high purity with the resultant problems of mechanical construction. Another is the substantial neutron leakage from the column outside the aperture into the experimental bunker. Furthermore the absence of a gamma shield has led to an electron dose to the skin. This is resolved with an electron shield of aluminium. Here the construction and final design issues are discussed and the state of the project is presented. (author)

  16. Development of slow neutron dose meter by track counting

    International Nuclear Information System (INIS)

    Nozaki, Tetsuya; Takeuchi, Hiroshi; Hasnel, S.; Honda, Teruyuki; Harasawa, Susumu.

    1993-01-01

    Prototypes of a plate type and two types of semispherical dosemeter were manufactured and their performances were tested. Polyallyl diglycol carbonate (PADC) was employed as neutron detector and covered with natural LiF and 6 Li-enriched LiF ceramics. They were irradiated in the TRIGA II Reactor of the Rikkyo University, and the sensitivity characteristics for incident angles and neutron energies were analyzed. It is concluded that it may be possible to manufacture small sized neutron dosemeter of flat response to wide energy range from thermal neutrons to epithermal neutrons with sufficient sensitivity for personal monitoring, using LiF ceramic as neutron filters and neutron converters. However the following issues are to be solved: the optimization of thickness of the LiF filter, the effects of albedo of the human body, and the applicability to the intermediate neutrons. (A.Y.)

  17. Neutron beam measurement dosimetry

    International Nuclear Information System (INIS)

    Amaro, C.R.

    1995-01-01

    This report describes animal dosimetry studies and phantom measurements. During 1994, 12 dogs were irradiated at BMRR as part of a 4 fraction dose tolerance study. The animals were first infused with BSH and irradiated daily for 4 consecutive days. BNL irradiated 2 beagles as part of their dose tolerance study using BPA fructose. In addition, a dog at WSU was irradiated at BMRR after an infusion of BPA fructose. During 1994, the INEL BNCT dosimetry team measured neutron flux and gamma dose profiles in two phantoms exposed to the epithermal neutron beam at the BMRR. These measurements were performed as a preparatory step to the commencement of human clinical trials in progress at the BMRR

  18. Combined neutron activation analysis techniques for multiple purposes at Portuguese research reactor

    International Nuclear Information System (INIS)

    Dung, H.M.; Freitas, M.C.; Beasley, D.; Almeida, S.M.; Dionisio, I; Canha, N.H.; Galinha, C.; Marques, J.G.

    2010-01-01

    Full text: Developments of the neutron activation analysis (NAA) techniques using Compton suppression system (CSS), fast pneumatic irradiation facility (SIPRA), epithermal neutron and automatic sample changers (ASCs) associated with the traditional NAA for trace element determination in various sample types are described with reference to specific conditions at the 1 MW Portuguese research reactor (RPI). Experiences in application of k o -IAEA software for data processing in order to deduce the results are also discussed. A selected number of sample types which are intended to the application in biological and environmental areas as well as industrial and material samples are demonstrated which provide challenges in the irradiation, measurement and the interpretation of data to which in most cases a combined solution should be made. The role that each NAA technique can play in the combined scheme along with their optimized characteristics has been studied and shown. The combined NAA techniques at RPI established for on-going and potential projects as well as analysis service with respect to the element scope (48), typically Ag, Al, As, Au, Ba, Br, Ca, Cd, Ce, CI, Co, Cr, Cs, Cu, Dy, Er, Eu, F, Fe, Ga, Hf, Hg, I, In, K, La, Mg, Mn, Mo, Na, Rb, Sb, Sc, Se, Si, Sm, Sn, Sr, Ta, Tb, Th, Ti, U, V, W, Vb, Zn and Zr along with detection limits, accuracies and precision's have been evaluated as a trace analysis method meeting the requirements of the intended applications

  19. Borehole logging system

    International Nuclear Information System (INIS)

    Allen, L.S.

    1988-01-01

    A radioactive borehole logging tool employs an epithermal neutron detector having a neutron counter surrounded by an inner thermal neutron filter and an outer thermal neutron filter. Located between the inner and outer filters is a neutron moderating material for extending the lifetime of epithermal neutrons to enhance the counting rate of such epithermal neutrons by the neutron counter

  20. Non-destructive studies of fuel pellets by neutron resonance absorption radiography and thermal neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Tremsin, A.S., E-mail: ast@ssl.berkeley.edu [University of California, Berkeley, CA 94720 (United States); Vogel, S.C.; Mocko, M.; Bourke, M.A.M.; Yuan, V.; Nelson, R.O.; Brown, D.W. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Feller, W.B. [NOVA Scientific, Inc., 10 Picker Rd., Sturbridge, MA 01566 (United States)

    2013-09-15

    Many isotopes in nuclear materials exhibit strong peaks in neutron absorption cross sections in the epithermal energy range (1–1000 eV). These peaks (often referred to as resonances) occur at energies specific to particular isotopes, providing a means of isotope identification and concentration measurements. The high penetration of epithermal neutrons through most materials is very useful for studies where samples consist of heavy-Z elements opaque to X-rays and sometimes to thermal neutrons as well. The characterization of nuclear fuel elements in their cladding can benefit from the development of high resolution neutron resonance absorption imaging (NRAI), enabled by recently developed spatially-resolved neutron time-of-flight detectors. In this technique the neutron transmission of the sample is measured as a function of spatial location and of neutron energy. In the region of the spectra that borders the resonance energy for a particular isotope, the reduction in transmission can be used to acquire an image revealing the 2-dimensional distribution of that isotope within the sample. Provided that the energy of each transmitted neutron is measured by the neutron detector used and the irradiated sample possesses neutron absorption resonances, then isotope-specific location maps can be acquired simultaneously for several isotopes. This can be done even in the case where samples are opaque or have very similar transmission for thermal neutrons and X-rays or where only low concentrations of particular isotopes are present (<0.1 atom% in some cases). Ultimately, such radiographs of isotope location can be utilized to measure isotope concentration, and can even be combined to produce three-dimensional distributions using tomographic methods. In this paper we present the proof-of-principle of NRAI and transmission Bragg edge imaging performed at Flight Path 5 (FP5) at the LANSCE pulsed, moderated neutron source of Los Alamos National Laboratory. A set of urania mockup

  1. Neutron activation determination of iridium, gold, platinum, and silver in geologic samples

    International Nuclear Information System (INIS)

    Millard, H.T. Jr.

    1987-01-01

    In the procedure developed in this study, samples irradiated in the epithermal neutron facility of the U.S. Geological Survey TRIGA Reactor (Denver, Colorado) are treated with a mini-free assay technique. The iridium, gold, and silver are collected in a 1-gram metallic lead button. Primary contaminants at this stage are arsenic and antimony. These can be removed by heating the button with a mixture of sodium peroxide and sodium hydroxide. The resulting 0.2-gram lead bead is counted in a Compton suppression spectrometer. Carrier yields are determined by reirradiation of the lead beads. This procedure was applied to the U.S.G.S. Standard Rock PCC-1 and samples from K-T boundary sites in the Western Interior of North America. (author)

  2. Educational activities for neutron sciences

    International Nuclear Information System (INIS)

    Hiraka, Haruhiro; Ohoyama, Kenji; Iwasa, Kazuaki

    2011-01-01

    Since now we have several world-leading neutron science facilities in Japan, enlightenment activities for introducing neutron sciences, for example, to young people is an indispensable issue. Hereafter, we will report present status of the activities based on collaborations between universities and neutron facilities. A few suggestions for future educational activity of JSNS are also shown. (author)

  3. Research of accelerator-based neutron source for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Li Changkai; Ma Yingjie; Tang Xiaobin; Xie Qin; Geng Changran; Chen Da

    2013-01-01

    Background: 7 Li (p, n) reaction of high neutron yield and low threshold energy has become one of the most important neutron generating reactions for Accelerator-based Boron Neutron Capture Therapy (BNCT). Purpose Focuses on neutron yield and spectrum characteristics of this kind of neutron generating reaction which serves as an accelerator-based neutron source and moderates the high energy neutron beams to meet BNCT requirements. Methods: The yield and energy spectrum of neutrons generated by accelerator-based 7 Li(p, n) reaction with incident proton energy from 1.9 MeV to 3.0 MeV are researched using the Monte Carlo code-MCNPX2.5.0. And the energy and angular distribution of differential neutron yield by 2.5-MeV incident proton are also given in this part. In the following part, the character of epithermal neutron beam generated by 2.5-MeV incident protons is moderated by a new-designed moderator. Results: Energy spectra of neutrons generated by accelerator-based 7 Li(p, n) reaction with incident proton energy from 1.9 MeV to 3.0 MeV are got through the simulation and calculation. The best moderator thickness is got through comparison. Conclusions: Neutron beam produced by accelerator-based 7 Li(p, n) reaction, with the bombarding beam of 10 mA and the energy of 2.5 MeV, can meet the requirement of BNCT well after being moderated. (authors)

  4. Beam neutron energy optimization for boron neutron capture therapy using monte Carlo method

    International Nuclear Information System (INIS)

    Pazirandeh, A.; Shekarian, E.

    2006-01-01

    In last two decades the optimal neutron energy for the treatment of deep seated tumors in boron neutron capture therapy in view of neutron physics and chemical compounds of boron carrier has been under thorough study. Although neutron absorption cross section of boron is high (3836b), the treatment of deep seated tumors such as glioblastoma multiform requires beam of neutrons of higher energy that can penetrate deeply into the brain and thermalized in the proximity of the tumor. Dosage from recoil proton associated with fast neutrons however poses some constraints on maximum neutron energy that can be used in the treatment. For this reason neutrons in the epithermal energy range of 10eV-10keV are generally to be the most appropriate. The simulation carried out by Monte Carlo methods using MCBNCT and MCNP4C codes along with the cross section library in 290 groups extracted from ENDF/B6 main library. The ptimal neutron energy for deep seated tumors depends on the sue and depth of tumor. Our estimated optimized energy for the tumor of 5cm wide and 1-2cm thick stands at 5cm depth is in the range of 3-5keV

  5. Analysis of neutron flux increase in the horizontal experimental channels of Ra reactor - masters thesis

    International Nuclear Information System (INIS)

    Strugar, P.

    1964-12-01

    Calculation and experimental results shown in this paper show that higher thermal neutron flux is obtained in the reactor core with central horizontal reflector at the same power level. The flux is increased when the moderation capability of the core is decreased. Apart from increase of the thermal component of the neutron flux in the experimental channels, the central reflector causes decrease of the epithermal neutron flux and gamma radiation intensity. This is very useful for studying (n, γ) reaction, neutron diffraction, etc. [sr

  6. Assessment of Laser-Driven Pulsed Neutron Sources for Poolside Neutron-based Advanced NDE – A Pathway to LANSCE-like Characterization at INL

    Energy Technology Data Exchange (ETDEWEB)

    Roth, Markus [Technische Univ. Darmstadt (Germany); Vogel, Sven C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bourke, Mark Andrew M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Fernandez, Juan Carlos [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mocko, Michael Jeffrey [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Glenzer, Siegfried [Stanford Univ., CA (United States); Leemans, Wim [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Siders, Craig [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Haefner, Constantin [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-04-19

    A variety of opportunities for characterization of fresh nuclear fuels using thermal (~25meV) and epithermal (~10eV) neutrons have been documented at Los Alamos National Laboratory. They include spatially resolved non-destructive characterization of features, isotopic enrichment, chemical heterogeneity and stoichiometry. The LANSCE spallation neutron source is well suited in neutron fluence and temporal characteristics for studies of fuels. However, recent advances in high power short pulse lasers suggest that compact neutron sources might, over the next decade, become viable at a price point that would permit their consideration for poolside characterization on site at irradiation facilities. In a laser-driven neutron source the laser is used to accelerate deuterium ions into a beryllium target where neutrons are produced. At this time, the technology is new and their total neutron production is approximately four orders of magnitude less than a facility like LANSCE. However, recent measurements on a sub-optimized system demonstrated >1010 neutrons in sub-nanosecond pulses in predominantly forward direction. The compactness of the target system compared to a spallation target may allow exchanging the target during a measurement to e.g. characterize a highly radioactive sample with thermal, epithermal, and fast neutrons as well as hard X-rays, thus avoiding sample handling. At this time several groups are working on laser-driven neutron production and are advancing concepts for lasers, laser targets, and optimized neutron target/moderator systems. Advances in performance sufficient to enable poolside fuels characterization with LANSCE-like fluence on sample within a decade may be possible. This report describes the underlying physics and state-of-the-art of the laser-driven neutron production process from the perspective of the DOE/NE mission. It also discusses the development and understanding that will be necessary to provide customized capability for

  7. Instrumentation at pulsed neutron sources

    International Nuclear Information System (INIS)

    Carpenter, J.M.; Lander, G.H.; Windsor, C.G.

    1984-01-01

    Scientific investigations involving the use of neutron beams have been centered at reactor sources for the last 35 years. Recently, there has been considerable interest in using the neutrons produced by accelerator driven (pulsed) sources. Such installations are in operation in England, Japan, and the United States. In this article a brief survey is given of how the neutron beams are produced and how they can be optimized for neutron scattering experiments. A detailed description is then given of the various types of instruments that have been, or are planned, at pulsed sources. Numerous examples of the scientific results that are emerging are given. An attempt is made throughout the article to compare the scientific opportunities at pulsed sources with the proven performance of reactor installations, and some familiarity with the latter and the general field of neutron scattering is assumed. New areas are being opened up by pulsed sources, particularly with the intense epithermal neutron beams, which promise to be several orders of magnitude more intense than can be obtained from a thermal reactor

  8. A physical and engineering study on the irradiation techniques in neutron capture therapy aiming for wider application

    International Nuclear Information System (INIS)

    Sakurai, Y.; Ono, K.; Suzuki, M.; Katoh, I.; Miyatake, S.-I.; Yanagie, H.

    2003-01-01

    The solo-irradiation of thermal neutrons has been applied for brain cancer and malignant melanoma in the boron neutron capture therapy (BNCT) at the medical irradiation facility of Kyoto University Reactor (KUR), from the first clinical trial in 1974. In 1997, after the facility remodeling, the application of the mix-irradiation of thermal and epi-thermal neutrons was started, and the depth dose distribution for brain cancer has been improved in some degree. In 2001, the solo-irradiation of epi-thermal neutrons also started. It is specially mentioned that the application to oral cancers started at the same time. The BNCT clinical trial using epi-thermal neutron irradiation at KUR, amounts to twelve as of March 2003. The seven trials; more than a half of the total trials, are for oral cancers. From this fact, we think that the wider application to the other cancers is required for the future prosperity of BNCT. The cancers applied for BNCT in KUR at the present time, are brain cancer, melanoma and oral cancers, as mentioned above. The cancers, expected to be applied in near future, are liver cancer, pancreas cancer, lung cancer, tongue cancer, breast cancer, etc.. Any cancer is almost incurable by the other therapy including the other radiation therapy. In the wider application of BNCT to these cancers, the dose-distribution control suitable to each cancer and/or each part, is important. The introduction of multi-directional and/or multi-divisional irradiation is also needed. Here, a physical and engineering study using two-dimensional transport calculation and three-dimensional Monte-Carlo simulation for the irradiation techniques in BNCT aiming for wider application is reported

  9. Simulation study of accelerator based quasi-mono-energetic epithermal neutron beams for BNCT.

    Science.gov (United States)

    Adib, M; Habib, N; Bashter, I I; El-Mesiry, M S; Mansy, M S

    2016-01-01

    Filtered neutron techniques were applied to produce quasi-mono-energetic neutron beams in the energy range of 1.5-7.5 keV at the accelerator port using the generated neutron spectrum from a Li (p, n) Be reaction. A simulation study was performed to characterize the filter components and transmitted beam lines. The feature of the filtered beams is detailed in terms of optimal thickness of the primary and additive components. A computer code named "QMNB-AS" was developed to carry out the required calculations. The filtered neutron beams had high purity and intensity with low contamination from the accompanying thermal, fast neutrons and γ-rays. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Procedure and code for calculating black control rods taking into account epithermal absorption, code CAS-1; Postupak i program za proracun crnih kontrolnih sipki, uzimajuci u obzir i epitermalnu apsorpciju, CAS-1

    Energy Technology Data Exchange (ETDEWEB)

    Martinc, R; Trivunac, N; Zivkovic, Z [Boris Kidric Institute of nuclear sciences Vinca, Belgrade (Yugoslavia)

    1964-12-15

    This report describes the computer code CAS-1, calculation method and procedure applied for calculating the black control rods taking into account the epithermal neutron absorption. Results obtained for supercell method applied for regular lattice reflected in the multiplication medium is part of this report in addition to the computer code manual.

  11. Fast neutron activation analysis by means of low voltage neutron generator

    Directory of Open Access Journals (Sweden)

    M.E. Medhat

    Full Text Available A description of D-T neutron generator (NG is presented. This machine can be used for fast neutron activation analysis applied to determine some selected elements, especially light elements, in different materials. Procedure of neutron flux determination and efficiency calculation is described. Examples of testing some Egyptian natural cosmetics are given. Keywords: Neutron generator, Fast neutron activation analysis, Elemental analysis

  12. Neutron Research in HANARO

    International Nuclear Information System (INIS)

    Kim, Hark Rho

    2005-01-01

    HANARO (High-flux Advanced Neutron Application Reactor), which was designed and constructed by indigenous technology, is a world-class multi-purpose research reactor with a design thermal power of 30 MW, providing high neutron flux for various applications in Korea. HANARO has been operated since its first criticality in February 1995, and is now successfully utilized in such areas as neutron beam research, fuel and materials tests, radioisotopes and radiopharmaceuticals production, neutron activation analysis, and neutron transmutation doping, etc. A number of experimental facilities have been developed and installed since the beginning of reactor operation, and R and D activities for installing more facilities are actively under progress. Three flux traps in the core (CT, IR1, IR2), providing a high fast neutron flux, can be used for materials and fuel irradiation tests. They are also proper for production of high specific activity radioisotopes. Four vertical holes in the outer core region, abundant in epithermal neutrons, are used for fuel or material tests and radioisotope production. In the heavy water reflector region, 25 vertical holes with high quality thermal neutrons are located for radioisotope production, neutron activation analysis, neutron transmutation doping and cold neutron source installation. The two largest holes named NTD1 and NTD2 are for neutron transmutation doping, CNS for the cold neutron source installation, and LH for the irradiation of large targets. The high resolution powder diffractometer (HRPD) became operational in 1998, followed by the four circle diffractometer (FCD) in 1999, the residual stress instrument (RSI) in 2000, and the small angle neutron spectrometer (SANS) in 2001, respectively. HRPD and SANS became the most popular instruments these days, attracting wide range of users from academia, institutes and industries. We have made a lot of efforts during the last 10 years to develop some key components such as

  13. Bulk hydrogen analysis, using neutrons. Final report of the first research co-ordination meeting

    International Nuclear Information System (INIS)

    1997-07-01

    There are many situations when hydrogen is required to be measured in a bulk medium. For this reason neutrons are used due to their high penetrating power in dense material. In addition, the mass attenuation coefficient for neutrons in hydrogen is significantly larger than for all other elements, meaning that neutrons have a higher probability of interacting with hydrogen than with other elements in the sample matrix. This CRP was recommended for further development of the techniques and new applications in the following areas: Fast Neutron/Gamma Transmission Technique; Digital Neutron Imaging; Hydrogen Detection by Epithermal Neutrons; Microscopic Behaviour of Hydrogen in Bulk Materials

  14. Physical engineering and medical physics on boron neutron capture therapy

    International Nuclear Information System (INIS)

    Sakurai, Yoshinori

    2011-01-01

    The contents of physical engineering and medical physics that support boron neutron capture therapy (BNCT) can be roughly classified to the four items, (1) neutron irradiation system, (2) development and improvement of dose assessment techniques, (3) development and improvement of dose planning system, and (4) quality assurance and quality control. This paper introduces the BNCT at Kyoto University Research Reactor Institute, with a focus on the basic physics of BNCT, thermal neutron irradiation and epithermal neutron irradiation, heavy water neutron irradiation facilities of KUR, and medical irradiation system of KUR. It also introduces the world's first BNCT clinical cyclotron irradiation system (C-BENS) of Kyoto University Research Reactor Institute, BNCT dose assessment techniques, dose planning system, and quality assurance and quality control. (A.O.)

  15. Medical and biological requirements for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Gahbauer, R.; Goodman, J.H.; Kanellitsas, C.; Clendenon, N.; Blue, J.

    1986-01-01

    In conventional radiation therapy, tumor doses applied to most solid tumors are limited by the tolerance of normal tissues. The promise of Boron Neutron Capture Therapy lies in its potential to deposit high doses of radiation very specifically to tumor tissue. Theoretically ratios of tumor to normal tissue doses can be achieved significantly higher than conventional radiotherapeutic techniques would allow. Effective dose distributions obtainable are a complex function of the neutron beam characteristics and the macro and micro distributions of boron in tumor and normal tissues. Effective RBE doses are calculated in tumors and normal tissue for thermal, epithermal and 2 keV neutrons

  16. Neutron transport from targets to moderators

    International Nuclear Information System (INIS)

    Taylor, A.D.

    1980-01-01

    The title of this meeting is 'Targets for Neutron Beam Spallation Sources', but so far all the emphasis in the talks has been on how to produce the fast neutron flux. I would like to stress that that is just the beginning of the story. What we are required to produce are beams of thermal and epithermal neutrons with time and spectral characteristics tailored to the instrumental requirements. The real source of our neutrons is not uranium arrays or thorium cylinders but a small volume of hydrogenous material, some 10 x 10 x 5 cm 3 . This is really what the whole thing is about - the target produces a copious field of fast neutrons, but if we fail to moderate them with the right energy and time characteristics, we will not match to what is happening downstream. In this talk, I am going to deal specifically with what we have done for SNS to optimise the target-moderator-reflector and decoupler system in this respect. (orig.)

  17. Characterization of the Annular Core Research Reactor (ACRR Neutron Radiography System Imaging Plane

    Directory of Open Access Journals (Sweden)

    Kaiser Krista

    2016-01-01

    Full Text Available The Annular Core Research Reactor (ACRR at Sandia National Laboratories (SNL is an epithermal pool-type research reactor licensed up to a thermal power of 2.4 MW. The ACRR facility has a neutron radiography facility that is used for imaging a wide range of items including reactor fuel and neutron generators. The ACRR neutron radiography system has four apertures (65:1, 125:1, 250:1, and 500:1 available to experimenters. The neutron flux and spectrum as well as the gamma dose rate were characterized at the imaging plane for the ACRR's neutron radiography system for the 65:1, 125:1 and 250:1 apertures.

  18. User's manual of a supporting system for treatment planning in boron neutron capture therapy. JAERI computational dosimetry system

    CERN Document Server

    Kumada, H

    2002-01-01

    A boron neutron capture therapy (BNCT) with epithermal neutron beam is expected to treat effectively for malignant tumor that is located deeply in the brain. It is indispensable to estimate preliminarily the irradiation dose in the brain of a patient in order to perform the epithermal neutron beam BNCT. Thus, the JAERI Computational Dosimetry System (JCDS), which can calculate the dose distributions in the brain, has been developed. JCDS is a software that creates a 3-dimensional head model of a patient by using CT and MRI images and that generates a input data file automatically for calculation neutron flux and gamma-ray dose distribution in the brain by the Monte Carlo code: MCNP, and that displays the dose distribution on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By treating CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to ...

  19. Tests of time reversal in neutron-nucleus scattering

    International Nuclear Information System (INIS)

    Bowman, J.D.

    1988-01-01

    Experiments to test time-reversal invariance are discussed. The experiments are based on observables constructed from the momentum and spin vectors of epithermal neutrons and from the spin of an aligned or polarized target. It is shown that the proposed tests are detailed balance tests of time-reversal invariance. The status of the experiments is briefly reviewed. 14 refs., 5 figs

  20. Design of an irradiation facility with thermal, epithermal and fast neutron beams

    International Nuclear Information System (INIS)

    Pfister, G.; Bernnat, W.; Seidel, R.; Schatz, A.K.; Wagner, F.M.; Waschkowski, W.; Schraube, H.

    1992-01-01

    The main features of a neutron irradiation facility to be installed at the planned research reactor FRM-II are presented. In addition to the operational possibilities of the existing facility at the reactor FRM-I, the new facility will produce quasi-monoenergetic neutron fields and a neutron beam in the keV region whose spectrum can be modified by application of suitable filters and scatterers. For this beam, which is well suited for boron capture therapy, calculated boron reaction rates inside a phantom and an experimental verification of the calculations at the existing facility are presented. (orig.) [de

  1. Neutron, gamma and Roentgen fluorescent activation analysis of hair of children suffering from bronchial asthma

    International Nuclear Information System (INIS)

    Alekseeva, O.A.; Belov, A.G.; Frontasyeva, M.V.; Gundorina, S.F.; Gustova, M.V.; Kusmenko, L.G.; Perelygin, V.P.; Zaverioukha, O.S.

    2001-01-01

    The aim of present study was the multiparametric study of dangerous microelements content in the hair of children under school and primary school age which included 12 children ill with bronchial asthma and 11 control group persons in the town of Troitsk, Moscow Region. The hair specimens with weight 15-220 mg were analysed with the application of epithermal neutron activation analysis conducted at experimental installation REGATA and neutron source-unique Pulsed Fast Reactor IBR-2, with the application of combined gamma-neutron irradiation at Microtron MT-25 and with Roentgen Fluorescence Analysis device of JINR. The data of elements content in hair were obtained with solid state track detectors and semiconductor electronic spectrometers. The solid state track detectors provide the determination of U, Th, Bi and Be elements at the level of sensitivity up to 10 -8 -10 -9 g/g. These data were compared with more representative information about dangerous microelements concentration obtained with NAA and RFA analyses. The obtained concentrations of most elements vary in a wide range, but in agreement with the known data. The highest degree of element dispersion was observed for U, Th, Pb, I, Br, Sb, Co, K and Be (the radiation coefficient was higher than 100-200%). The presented analysis of results shows that in the clinical picture there is some proved correlation between an increased content of some element in hair and symptoms of their accumulation in the organism of ill children, the revelation of which is the basic idea of our examination

  2. Evaluation for activities of component of Cyclotron-Based Epithermal Neutron Source (C-BENS) and the surface of concrete wall in irradiation room

    Energy Technology Data Exchange (ETDEWEB)

    Imoto, M., E-mail: masayuki.imoto@gmail.com [Graduate School of Engineering, Kyoto University, Kyoto 606-8501 (Japan); Tanaka, H. [Research Reactor Institute, Kyoto University, Osaka 590-0494 (Japan); Fujita, K.; Mitsumoto, T. [Sumitomo Heavy Industries, Ltd., Tokyo 141-6025 (Japan); Ono, K.; Maruhashi, A.; Sakurai, Y. [Research Reactor Institute, Kyoto University, Osaka 590-0494 (Japan)

    2011-12-15

    The workers employed in BNCT must enter the irradiation room just after an irradiation under the condition of remaining activities. To reduce the radiation exposure for the workers, it is important to identify the origins of the activities. In this research, the activities induced on the concrete wall surface were evaluated using MCNP-5 and the measurement results of thermal neutron distribution. Furthermore, the radioisotopes produced in the moderator were identified with a High Purity Germanium detector. It was found that the activities of the wall were mainly caused by {sup 46}Sc, {sup 60}Co and {sup 152}Eu, and that {sup 24}Na and {sup 56}Mn were mainly produced in the moderator.

  3. Manually controlled neutron-activation system

    International Nuclear Information System (INIS)

    Johns, R.A.; Carothers, G.A.

    1982-01-01

    A manually controlled neutron activation system, the Manual Reactor Activation System, was designed and built and has been operating at one of the Savannah River Plant's production reactors. With this system, samples can be irradiated for up to 24 hours and pneumatically transferred to a shielded repository for decay until their activity is low enough for them to be handled at a radiobench. The Manual Reactor Activation System was built to provide neutron activation of solid waste forms for the Alternative Waste Forms Leach Testing Program. Neutron activation of the bulk sample prior to leaching permits sensitive multielement radiometric analyses of the leachates

  4. Physical parameters and biological effects of the LVR-15 epithermal neutron beam

    Czech Academy of Sciences Publication Activity Database

    Burian, J.; Gambarini, G.; Marek, M.; Mareš, Vladislav; Rejchrt, J.; Vanossi, E.; Viererbl, L.; Judas, L.

    -, - (2006), s. 481-484 [International Congress on Neutron Capture Therapy /12./. Kagawo, 09.10.2006-13.10.2006] R&D Projects: GA MPO(CZ) 1H-PK2/05 Institutional research plan: CEZ:AV0Z50110509 Keywords : brain tumors * neutron capture therapy * NTC * dosimetry Subject RIV: FD - Oncology ; Hematology

  5. Evaluation of mixed energy neutron doses using TLD NG-67 type

    International Nuclear Information System (INIS)

    Akhadi, Mukhlis; Thoyib Thamrin, M; Usmiyati Dewi, K.

    2000-01-01

    A research has been carried out to develop dose evaluation method of mixed neutron source with its neutron doses can be classified to two groups, I.e neutron doses with energy ≥ 0.5 eV and thermal neutron doses with energy less than 0.5 e V consist of epithermal and fast neutron, but in this research they were classified as fast neutron. Development of this dose evaluation method was carried out by sensitivity (S) intercomparison of TLD-600 to fast neutron, mixed energy neutron of nuclear rectors, and thermal neutron. From the experiment it was obtained that the value of Sfast : Sreactor : Sthermal = 0.005 : 0.010 : 1. Calibration factor (CF) of TLD is defined as 1/S. from the sensitivity data it can be obtained that the value of Cffast : Cfreactor : Cfthermal = 200 :100 : 1. The value of Cfreactor can be applied for mixed energy neutron doses evaluation of TLD-600. Key word : dosemeter, neutron dose, calibration factor, fast neutron, thermal neutron, nuclear reactor

  6. Limitations for qualitative and quantitative neutron activation analysis using reactor neutrons

    International Nuclear Information System (INIS)

    El-Abbady, W.H.; El-Tanahy, Z.H.; El-Hagg, A.A.; Hassan, A.M.

    1999-01-01

    In this work, the most important limitations for qualitative and quantitative analysis using reactor neutrons for activation are reviewed. Each limitation is discussed using different examples of activated samples. Photopeak estimation, nuclear reactions interference and neutron flux measurements are taken into consideration. Solutions for high accuracy evaluation in neutron activation analysis applications are given. (author)

  7. Study the Possibility of measuring Heavy Metals Arising from Gold Mining Sample using 252Cf Neutron Source

    International Nuclear Information System (INIS)

    Soliman, N.F.

    2012-01-01

    Mining activities contribute immensely to trace element pollution .The present work studied the possibility of measuring heavy metals arising from gold mining areas Eastern Desert in Egypt using the isotopic 252 Cf neutron source. 38.5 g of the sample is irradiated in a neutron field of 252 Cf for 36.75 days and 0.3 mg of the sample is irradiated at the Pneumatic Irradiation Rabbit System (PIRS) built in the vertical thermal column of the ET-RR-2 reactor . The induced activities in the samples are measured using two high resolution f ray spectrometry systems (including two calibrated HPGe detectors). The kο standardization neutron activation analysis (kο-NAA) method was used to analyze the sample under investigation. Thermal to epithermal flux ratio fat the two irradiation positions are measured. The obtained results indicated that the values of the suspected heavy metals such as sodium, magnesium, potassium, manganese, arsenic, ruthenium and tantalum were higher than the background values, signifying accumulation of these heavy metals due to gold mining activities .The accuracy and precision of the method has been evaluated

  8. Development of the Method of Bacterial Leaching of Metals out of Low-Grade Ores, Rocks, and Industrial Wastes Using Neutron Activation Analysis

    CERN Document Server

    Tsertsvadze, L A; Petriashvili, Sh G; Chutkerashvili, D G; Kirkesali, E I; Frontasyeva, M V; Pavlov, S S; Gundorina, S F

    2001-01-01

    The results of preliminary investigations aimed at the development of an economical and easy to apply technique of bacterial leaching of rare and valuable metals out of low-grade ores, complex composition ores, rocks, and industrial wastes in Georgia are discussed. The main groups of microbiological community of the peat suspension used in the experiments of bacterial leaching are investigated and the activity of particular microorganisms in the leaching of probes with different mineral compositions is assessed. The element composition of the primary and processed samples was investigated by the epithermal neutron activation analysis method and the enrichment/subtraction level is estimated for various elements. The efficiency of the developed technique to purify wastes, extract some scrace metals, and enrich ores or rocks in some elements, e.g. Au, U, Th, Cs, Sr, Rb, Sc, Zr, Hf, Ta, Gd, Er, Lu, Ce, etc., is demonstrated.

  9. Assessing neutron generator output using neutron activation of silicon

    International Nuclear Information System (INIS)

    Kehayias, Pauli M.; Kehayias, Joseph J.

    2007-01-01

    D-T neutron generators are used for elemental composition analysis and medical applications. Often composition is determined by examining elemental ratios in which the knowledge of the neutron flux is unnecessary. However, the absolute value of the neutron flux is required when the generator is used for neutron activation analysis, to study radiation damage to materials, to monitor the operation of the generator, and to measure radiation exposure. We describe a method for absolute neutron output and flux measurements of low output D-T neutron generators using delayed activation of silicon. We irradiated a series of silicon oxide samples with 14.1 MeV neutrons and counted the resulting gamma rays of the 28 Al nucleus with an efficiency-calibrated detector. To minimize the photon self-absorption effects within the samples, we used a zero-thickness extrapolation technique by repeating the measurement with samples of different thicknesses. The neutron flux measured 26 cm away from the tritium target of a Thermo Electron A-325 D-T generator (Thermo Electron Corporation, Colorado Springs, CO) was 6.2 x 10 3 n/s/cm 2 ± 5%, which is consistent with the manufacturer's specifications

  10. Assessing neutron generator output using neutron activation of silicon

    Energy Technology Data Exchange (ETDEWEB)

    Kehayias, Pauli M. [Body Composition Laboratory, Jean Mayer United States Department of Agriculture Human Nutrition Research Center on Aging, Tufts University, Boston, MA 02111 (United States); Kehayias, Joseph J. [Body Composition Laboratory, Jean Mayer United States Department of Agriculture Human Nutrition Research Center on Aging, Tufts University, Boston, MA 02111 (United States)]. E-mail: joseph.kehayias@tufts.edu

    2007-08-15

    D-T neutron generators are used for elemental composition analysis and medical applications. Often composition is determined by examining elemental ratios in which the knowledge of the neutron flux is unnecessary. However, the absolute value of the neutron flux is required when the generator is used for neutron activation analysis, to study radiation damage to materials, to monitor the operation of the generator, and to measure radiation exposure. We describe a method for absolute neutron output and flux measurements of low output D-T neutron generators using delayed activation of silicon. We irradiated a series of silicon oxide samples with 14.1 MeV neutrons and counted the resulting gamma rays of the {sup 28}Al nucleus with an efficiency-calibrated detector. To minimize the photon self-absorption effects within the samples, we used a zero-thickness extrapolation technique by repeating the measurement with samples of different thicknesses. The neutron flux measured 26 cm away from the tritium target of a Thermo Electron A-325 D-T generator (Thermo Electron Corporation, Colorado Springs, CO) was 6.2 x 10{sup 3} n/s/cm{sup 2} {+-} 5%, which is consistent with the manufacturer's specifications.

  11. Neutron activation spectrometry and neutron activation analysis in analytical geochemistry

    International Nuclear Information System (INIS)

    Dulski, P.; Moeller, P.

    1975-07-01

    The present report is to show the geochemists who are interested in neutron activation spectrometry (NAS) and neutron activation analysis (NAA) which analytical possibilities these methods offer him. As a review of these analytical possibilities, a lieterature compolation is given which is subdivided into two groups: 1) rock (basic, intermediary, acid, sediments, soils and nuds, diverse minerals, tectites, meteorites and lunar material). 2) ore (Al, Au, Be, Cr, Cu, Mn, Mo, Fe, Pb, Pt, Sn, Ti, W, Zn, Zr, U and phosphate ore, polymetallic ores, fluorite, monazite and diverse ores). The applied methods as well as the determinable elements in the given materials can be got from the tables. On the whole, the literature evaluation carried out makes it clear that neutron activation spectrometry is a very useful multi-element method for the analysis of rocks. The analysis of ores, however, is subjected to great limitations. As rock analysis is very frequently of importance in prospecting for ore deposits, the NAS proves to be extremely useful for this very field of application. (orig./LH) [de

  12. Calculations of neutron source at the KYIV research reactor for the boron neutron capture therapy aims

    International Nuclear Information System (INIS)

    Gritzay, O.; Kalchenko, O.; Klimova, N.; Razbudey, V.; Sanzhur, A.

    2006-01-01

    Calculation results of an epithermal neutron source which can be created at the Kyiv Research Reactor (KRR) by means of placing of specially selected moderators, filters, collimators, and shielding into the 10-th horizontal experimental tube (so-called thermal column) are presented. The general Monte-Carlo radiation transport code MCNP4C [1], the Oak Ridge isotope generation code ORIGEN2 [2] and the NJOY99 [3] nuclear data processing system have been used for these calculations

  13. Method of assaying uranium with prompt fission and thermal neutron borehole logging adjusted by borehole physical characteristics

    International Nuclear Information System (INIS)

    Barnard, R.W.; Jensen, D.H.

    1982-01-01

    Uranium formations are assayed by prompt fission neutron logging techniques. The uranium in the formation is proportional to the ratio of epithermal counts to thermal or eqithermal dieaway. Various calibration factors enhance the accuracy of the measurement

  14. Neutron fluence spectrometry using disk activation

    International Nuclear Information System (INIS)

    Loevestam, Goeran; Hult, Mikael; Fessler, Andreas; Gasparro, Joel; Kockerols, Pierre; Okkinga, Klaas; Tagziria, Hamid; Vanhavere, Filip; Wieslander, J.S. Elisabeth

    2009-01-01

    A simple and robust detector for spectrometry of environmental neutrons has been developed. The technique is based on neutron activation of a series of different metal disks followed by low-level gamma-ray spectrometry of the activated disks and subsequent neutron spectrum unfolding. The technique is similar to foil activation but here the applied neutron fluence rates are much lower than usually in the case of foil activation. The detector has been tested in quasi mono-energetic neutron fields with fluence rates in the order of 1000-10000 cm -2 s -1 , where the obtained spectra showed good agreement with spectra measured using a Bonner sphere spectrometer. The detector has also been tested using an AmBe source and at a neutron fluence rate of about 40 cm -2 s -1 , again, a good agreement with the assumed spectrum was achieved

  15. Neutron absorbed dose in a pacemaker CMOS

    International Nuclear Information System (INIS)

    Borja H, C. G.; Guzman G, K. A.; Valero L, C.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R.; Paredes G, L.

    2012-01-01

    The neutron spectrum and the absorbed dose in a Complementary Metal Oxide Semiconductor (CMOS), has been estimated using Monte Carlo methods. Eventually a person with a pacemaker becomes an oncology patient that must be treated in a linear accelerator. Pacemaker has integrated circuits as CMOS that are sensitive to intense and pulsed radiation fields. Above 7 MV therapeutic beam is contaminated with photoneutrons that could damage the CMOS. Here, the neutron spectrum and the absorbed dose in a CMOS cell was calculated, also the spectra were calculated in two point-like detectors in the room. Neutron spectrum in the CMOS cell shows a small peak between 0.1 to 1 MeV and a larger peak in the thermal region, joined by epithermal neutrons, same features were observed in the point-like detectors. The absorbed dose in the CMOS was 1.522 x 10 -17 Gy per neutron emitted by the source. (Author)

  16. Neutron absorbed dose in a pacemaker CMOS

    Energy Technology Data Exchange (ETDEWEB)

    Borja H, C. G.; Guzman G, K. A.; Valero L, C.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Paredes G, L., E-mail: fermineutron@yahoo.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2012-06-15

    The neutron spectrum and the absorbed dose in a Complementary Metal Oxide Semiconductor (CMOS), has been estimated using Monte Carlo methods. Eventually a person with a pacemaker becomes an oncology patient that must be treated in a linear accelerator. Pacemaker has integrated circuits as CMOS that are sensitive to intense and pulsed radiation fields. Above 7 MV therapeutic beam is contaminated with photoneutrons that could damage the CMOS. Here, the neutron spectrum and the absorbed dose in a CMOS cell was calculated, also the spectra were calculated in two point-like detectors in the room. Neutron spectrum in the CMOS cell shows a small peak between 0.1 to 1 MeV and a larger peak in the thermal region, joined by epithermal neutrons, same features were observed in the point-like detectors. The absorbed dose in the CMOS was 1.522 x 10{sup -17} Gy per neutron emitted by the source. (Author)

  17. Sulfur, cobalt and europium activation from the A-bombs in Japan

    International Nuclear Information System (INIS)

    Gritzner, M.L.; Egbert, S.D.; Woolson, W.A.

    1987-01-01

    Comparisons are made between calculations and measurements of in-situ sulfur, cobalt, and europium activation by neutrons at Hiroshima and Nagasaki to check the validity of the neutron sources and transport air-over-ground used in the new Dosimetry System 1986 (DS86). Europium and cobalt are activated by epithermal/thermal neutrons. The sulfur activation has an effective threshold around 2 MeV. Comparisons of sulfur activation at Hiroshima, which necessitate considering the tilt and heading of the cylindrically shaped Little Boy bomb, confirm the high energy neutron portion of the source relevant to sulfur activation. The europium and cobalt activation calculations tend to be higher than the measurements for ground ranges within 300 m and lower than the measurements beyond 700 m. Thus, the cobalt and europium measurements do not validate the source or the transport, embodied in DS87, for those neutrons relevant to europium and cobalt activation. Presently, it is unresolved as to whether the discrepancy can be explained as a problem in the measurements, in their interpretation, or as a problem in the calculations due to the source neutrons and/or their transport from source to the sample site

  18. 9Be(d,n)10B-based neutron sources for BNCT

    International Nuclear Information System (INIS)

    Capoulat, M.E.; Herrera, M.S.; Minsky, D.M.; González, S.J.; Kreiner, A.J.

    2014-01-01

    In the frame of accelerator-based BNCT, the 9 Be(d,n) 10 B reaction was investigated as a possible source of epithermal neutrons. In order to determine the configuration in terms of bombarding energy, target thickness and Beam Shaping Assembly (BSA) design that results in the best possible beam quality, a systematic optimization study was carried out. From this study, the optimal configuration resulted in tumor doses ≥40 Gy-Eq, with a maximum value of 51 Gy-Eq at a depth of about 2.7 cm, in a 60 min treatment. The optimal configuration was considered for the treatment planning assessment of a real Glioblastoma Multiforme case. From this, the resulted dose performances were comparable to those obtained with an optimized 7 Li(p,n)-based neutron source, under identical conditions and subjected to the same clinical protocol. - Highlights: • Study of the 9 Be(d,n) 10 B reaction as a source of epithermal neutrons for BNCT. • Evaluation of the optimal configuration of target thickness, deuteron energy and BSA design. • Computational dose assessment for brain tumor treatments using the MCNP code. • Treatment planning assessment of a particular clinical Glioblastoma Multiforme case. • Dose performances were comparable to those obtained with an optimized 7 Li(p,n)-based source

  19. Boron Neutron Capture Therapy at European research reactors - Status and perspectives

    International Nuclear Information System (INIS)

    Moss, R.L.

    2004-01-01

    Over the last decade. there has been a significant revival in the development of Boron Neutron Capture Therapy (BNCT) as a treatment modality for curing cancerous tumours, especially glioblastoma multiforme and subcutaneous malignant melanoma. In 1987 a European Collaboration on BNCT was formed, with the prime task to identify suitable research reactors in Europe where BNCT could be applied. Due to reasons discussed in this paper, the HFR Petten was chosen as the test-bed for demonstrating BNCT. Currently, the European Collaboration is approaching the start of clinical trials, using epithermal neutrons and borocaptate sodium (BSH) as the 10 B delivery agent. The treatment is planned to start in the first half of 1996. The paper here presents an overview on the principle of BNCT, the requirements imposed on a research reactor in order to be considered for BNCT, and the perspectives for other European materials testing reactors. A brief summary on the current status of the work at Petten is given, including: the design, construction and characterisation of the epithermal neutron beam: performance and results of the healthy tissue tolerance study; the development of a treatment planning programme based on the Monte Carlo code MCNP; the design of an irradiation room; and on the clinical trials themselves. (author)

  20. Isotopic neutron sources for neutron activation analysis

    International Nuclear Information System (INIS)

    Hoste, J.

    1988-06-01

    This User's Manual is an attempt to provide for teaching and training purposes, a series of well thought out demonstrative experiments in neutron activation analysis based on the utilization of an isotopic neutron source. In some cases, these ideas can be applied to solve practical analytical problems. 19 refs, figs and tabs

  1. Effect of head size on 10B dose distribution

    International Nuclear Information System (INIS)

    Gupta, N.; Blue, T.E.; Gahbauer, R.

    1992-01-01

    Boron neutron capture therapy (BNCT) for treatment of brain tumors is based on the utilization of large epithermal-neutron fields. Epithermal neutrons thermalize at depths of ∼2.5 cm inside the head and provide a maximum thermal fluence at deep-seated tumor sites with minimum damage to normal tissue. Brain tissue is a highly scattering medium for epithermal and thermal neutrons; therefore, a broad treatment field enables epithermal neutrons to enter the head over a large area. These neutrons slow down as they undergo scattering collisions and contribute to the thermal-neutron fluence at the tumor location. With the use of large neutron fields, the size of the head affects the thermal-neutron distribution and thereby the 10 B absorbed dose distribution inside the head. In this paper, the authors describe measurements using a boron trifluoride (BF 3 )-filled proportional counter to determine the effect of head size on 10 B absorbed dose distributions for a broad field accelerator epithermal-neutron source

  2. Neutron fluence spectrometry using disk activation

    Energy Technology Data Exchange (ETDEWEB)

    Loevestam, Goeran [EC-JRC-Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, B-2440 Geel (Belgium)], E-mail: goeran.loevestam@ec.europa.eu; Hult, Mikael; Fessler, Andreas; Gasparro, Joel; Kockerols, Pierre; Okkinga, Klaas [EC-JRC-Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, B-2440 Geel (Belgium); Tagziria, Hamid [EC-JRC-Institute for the Protection and the Security of the Citizen (IPSC), Via E. Fermi 1, I-21020 Ispra (Vatican City State, Holy See,) (Italy); Vanhavere, Filip [SCK-CEN, Boeretang, 2400 Mol (Belgium); Wieslander, J.S. Elisabeth [EC-JRC-Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, B-2440 Geel (Belgium); Department of Physics, P.O. Box 35 (YFL), FIN-40014, University of Jyvaeskylae (Finland)

    2009-01-15

    A simple and robust detector for spectrometry of environmental neutrons has been developed. The technique is based on neutron activation of a series of different metal disks followed by low-level gamma-ray spectrometry of the activated disks and subsequent neutron spectrum unfolding. The technique is similar to foil activation but here the applied neutron fluence rates are much lower than usually in the case of foil activation. The detector has been tested in quasi mono-energetic neutron fields with fluence rates in the order of 1000-10000 cm{sup -2} s{sup -1}, where the obtained spectra showed good agreement with spectra measured using a Bonner sphere spectrometer. The detector has also been tested using an AmBe source and at a neutron fluence rate of about 40 cm{sup -2} s{sup -1}, again, a good agreement with the assumed spectrum was achieved.

  3. Neutron dosimeter utilizing CR-39

    International Nuclear Information System (INIS)

    Souza, H.V.C. de.

    1991-05-01

    A personnel neutron dosimeter has been developed with discretization in a wide range of energies of real interest, utilizing the CR-39 polymer, to detect recoil protons in the fast range, and alpha particles in the thermal and epithermal ranges, with possibility to be disposed in the IRD/CNEN's conventional film badge suport. They are presented, abstractly, the difficulties and importance of the neutron dosimetry, beyond the general objectives that motivated this work execution. The details of the materials utilized in the dosimeter confection, and the experimental methodology employed to obtain the performance curves are presented. The results about linearity response of the dosimeter with respect to equivalent dose, in a wide range of doses, and about the verified angular dependence are analysed. (author)

  4. Pulsed neutron generator for use with pulsed neutron activation techniques

    International Nuclear Information System (INIS)

    Rochau, G.E.

    1980-01-01

    A high-output, transportable, pulsed neutron generator has been developed by Sandia National Laboratories for use with Pulsed Neutron Activation (PNA) techniques. The PNA neutron generator generates > 10 10 14 MeV D-T neutrons in a 1.2 millisecond pulse. Each operation of the unit will produce a nominal total neutron output of 1.2 x 10 10 neutrons. The generator has been designed to be easily repaired and modified. The unit requires no additional equipment for operation or measurement of output

  5. The Swedish facility for boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Skoeld, K.; Capala, J. [Studsvik Medical AB (Sweden); Kierkegaard, J.; Haakansson, R. [Studsvik Nuclear AB (Sweden); Gudowska, I. [Karolinska Institute (Sweden)

    2000-10-01

    A BNCT (Boron Neutron Capture Therapy) facility has been constructed at the R2-0 reactor at Studsvik, Sweden. R2-0 is a 1 MW, open core, pool reactor. The reactor core is suspended on a movable tower and can be positioned anywhere in the pool. The BNCT facility includes two adjacent, parallel filter/moderator configurations and the reactor core is positioned in front of any of them as appropriate. One of the resulting neutron beams has been optimized for clinical irradiations with a filter/moderator system that allows easy variation of the neutron spectrum from the thermal to the epithermal energy range and with an extended collimator for convenient patient positioning. The other beam has been designed for radiobiological research and is equipped with a heavy water moderator and a large irradiation cavity with a uniform field of thermal neutrons. (author)

  6. The Swedish facility for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Skoeld, K.; Capala, J.; Kierkegaard, J.; Haakansson, R.; Gudowska, I.

    2000-01-01

    A BNCT (Boron Neutron Capture Therapy) facility has been constructed at the R2-0 reactor at Studsvik, Sweden. R2-0 is a 1 MW, open core, pool reactor. The reactor core is suspended on a movable tower and can be positioned anywhere in the pool. The BNCT facility includes two adjacent, parallel filter/moderator configurations and the reactor core is positioned in front of any of them as appropriate. One of the resulting neutron beams has been optimized for clinical irradiations with a filter/moderator system that allows easy variation of the neutron spectrum from the thermal to the epithermal energy range and with an extended collimator for convenient patient positioning. The other beam has been designed for radiobiological research and is equipped with a heavy water moderator and a large irradiation cavity with a uniform field of thermal neutrons. (author)

  7. Determination of hydrogen content by neutron techniques

    International Nuclear Information System (INIS)

    Santisteban, J.R.; Granada, J.R.; Mayer, R.E.

    1997-01-01

    The commonly available techniques for the determination of hydrogen dissolved in solids are usually destructive from the point of view of the sample. A new, nondestructive method for this kind of measurements has been developed at our laboratory, with the requirement of improved sensitivity for massive samples. This scattering method is based on the use of epithermal neutrons, and has been implemented through the design and construction of a spectrometer dedicated to that task. In addition, the traditional transmission method has been employed to determine hydrogen content in metals, using the full sub thermal and thermal neutron energy ranges. A pulsed neutron source based on an electron LINAC is employed, together with time-of-flight techniques. In this work we will present some results illustrative of the sensitivity achieved by these neutron techniques in different systems and for a wide range of hydrogen concentrations. (author) [es

  8. Development of high flux thermal neutron generator for neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Vainionpaa, Jaakko H., E-mail: hannes@adelphitech.com [Adelphi Technology, 2003 E Bayshore Rd, Redwood City, CA 94063 (United States); Chen, Allan X.; Piestrup, Melvin A.; Gary, Charles K. [Adelphi Technology, 2003 E Bayshore Rd, Redwood City, CA 94063 (United States); Jones, Glenn [G& J Jones Enterprice, 7486 Brighton Ct, Dublin, CA 94568 (United States); Pantell, Richard H. [Department of Electrical Engineering, Stanford University, Stanford, CA (United States)

    2015-05-01

    The new model DD110MB neutron generator from Adelphi Technology produces thermal (<0.5 eV) neutron flux that is normally achieved in a nuclear reactor or larger accelerator based systems. Thermal neutron fluxes of 3–5 · 10{sup 7} n/cm{sup 2}/s are measured. This flux is achieved using four ion beams arranged concentrically around a target chamber containing a compact moderator with a central sample cylinder. Fast neutron yield of ∼2 · 10{sup 10} n/s is created at the titanium surface of the target chamber. The thickness and material of the moderator is selected to maximize the thermal neutron flux at the center. The 2.5 MeV neutrons are quickly thermalized to energies below 0.5 eV and concentrated at the sample cylinder. The maximum flux of thermal neutrons at the target is achieved when approximately half of the neutrons at the sample area are thermalized. In this paper we present simulation results used to characterize performance of the neutron generator. The neutron flux can be used for neutron activation analysis (NAA) prompt gamma neutron activation analysis (PGNAA) for determining the concentrations of elements in many materials. Another envisioned use of the generator is production of radioactive isotopes. DD110MB is small enough for modest-sized laboratories and universities. Compared to nuclear reactors the DD110MB produces comparable thermal flux but provides reduced administrative and safety requirements and it can be run in pulsed mode, which is beneficial in many neutron activation techniques.

  9. Medical set-up of boron neutron capture therapy (BNCT) for malignant glioma at the Japan research reactor (JRR)-4

    International Nuclear Information System (INIS)

    Yamamoto, T.; Matsumura, A.; Nose, T.; Shibata, Y.; Nakai, K.; Sakurai, F.; Kishi, T.; Kumada, H.; Yamamoto, K.; Torii, Y.

    2001-01-01

    The University of Tsukuba project for boron neutron capture therapy (BNCT) was initiated at the Japan Atomic Energy Research Institute (JAERI) in 1992. The clinical study for BNCT began at the Japan Research Reactor (JRR)-2 of the JAERI in November 1995. By the end of 1998, a new medical irradiation facility had been installed in JRR-4 of that included a new medical treatment room and patient-monitoring area adjacent to the irradiation room. The medical treatment room was built to reflect a hospital-type operation room that includes an operating table with a carbon head frame, anesthesia apparatus with several cardiopulmonary monitors, etc. Following craniotomy in the treatment room, a patient under anesthesia is transported into the irradiation room for BNCT. The boron concentration in tissue is measured with prompt gamma ray analysis (PGA) and simultaneously by inductively coupled plasma atomic emission spectroscopy (ICP-AES) methods. For the immediate pre- and post-BNCT care, a collaborating neurosurgical department of the University of Tsukuba was prepared in the vicinity of the JAERI. The long term follow-up is done at the University of Tsukuba Hospital. Epithermal neutron beam also became available at the new JRR-4. By changing the thickness and/or the configuration of heavy water, a cadmium plate, and a graphite reflector, the JRR-4 provides a variety of neutron beams, including three typical beams (Epithermal mode and Thermal modes I and II). Intraoperative BNCT using the thermal beam is planned to study at the beginning of the clinical trial. The ongoing development of the JAERI Computational Dosimetry System (JCDS) and radiobiological studies have focused in the application of the epithermal beam for BNCT. After obtaining these basic data, we are planning to use the epithermal beam for intraoperative BNCT. (author)

  10. Use of neutron capture gamma radiation for determining grade of iron ore in blast holes and exploration holes

    International Nuclear Information System (INIS)

    Eisler, P.L.; Huppert, P.; Mathew, P.J.; Wylie, A.W.; Youl, S.F.

    1977-01-01

    Neutron radiative capture and neutron-neutron logging have been applied to determining the grade of ore in dry blast holes and a dry exploration hole drilled into a layered iron deposit. Both thermal and epithermal neutron responses were measured as well as the gamma-ray responses due to neutron capture by iron and by hydrogen present in hydrated minerals. The results were fitted by a stepwise multiple linear regression technique to give expressions for mean grade of ore in the drill hole and 95% confidence intervals for estimation of this mean. For an overall range of ore grades of 20-68% Fe and a mean grade of 63% Fe, the confidence interval for prediction of mean grade for the neutron-gamma technique was 0.3% Fe for pooled data from all five blast holes and 0.8% Fe for a single hole. It was also shown that for this type of layered deposit a simpler neutron-neutron log incorporating simultaneous measurement of both thermal and epithermal neutron responses gave almost as good a grade prediction result for pooled results from five drill holes, namely 63+-0.4% Fe, as that obtained by the neutron-gamma technique. The results of both types of log are compared with those obtained by the spectral gamma-ray backscattering [Psub(z)] technique, or by logging of natural gamma radiations from the shale component of the ore. From this comparison conclusions are drawn regarding the most suitable technique to employ for determining grade of iron ore in various practical logging situations. (author)

  11. Enhanced NIF neutron activation diagnostics.

    Science.gov (United States)

    Yeamans, C B; Bleuel, D L; Bernstein, L A

    2012-10-01

    The NIF neutron activation diagnostic suite relies on removable activation samples, leading to operational inefficiencies and a fundamental lower limit on the half-life of the activated product that can be observed. A neutron diagnostic system measuring activation of permanently installed samples could remove these limitations and significantly enhance overall neutron diagnostic capabilities. The physics and engineering aspects of two proposed systems are considered: one measuring the (89)Zr/(89 m)Zr isomer ratio in the existing Zr activation medium and the other using potassium zirconate as the activation medium. Both proposed systems could improve the signal-to-noise ratio of the current system by at least a factor of 5 and would allow independent measurement of fusion core velocity and fuel areal density.

  12. A 'hybrid' neutron area survey instrument for the determination of neutron dose quantities in the workplace

    International Nuclear Information System (INIS)

    Tanner, R.J.; Jenkins, R.; Lowe, T.; Silvie, J.; Joyce, M.J.; Winsby, A.; Molinos, C.

    2005-01-01

    Full text: Neutron survey instruments are used routinely to determine the dose rates in areas where persons may be occupationally exposed. With a few exceptions, these instruments generally use a proportional counter with a high thermal neutron response located in a moderating sphere of CH 2 . The moderating sphere in such designs contains a thermal neutron absorber to reduce the over-response to thermal and intermediate energy neutrons. However, the commercially available examples of such instruments tend to have strongly energy dependent ambient dose equivalent response characteristics. In particular, they often over-respond in the energy range between 1 eV and 10 keV. A prototype of a novel design has been produced that uses seven detectors located in a moderating sphere of CH 2 , six near the surface to detect thermal and epithermal neutrons, and one in the centre to detect fast neutrons. This has been characterized using a combination of MCNP modelling and measurements to produce an instrument that has improved energy dependence of response characteristics. Additionally, the use of seven detectors offers direction and field hardness information. The design and calibration of the instrument are described and its response in workplaces calculated. (author)

  13. Preliminary energy-filtering neutron imaging with time-of-flight method on PKUNIFTY: A compact accelerator based neutron imaging facility at Peking University

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hu; Zou, Yubin, E-mail: zouyubin@pku.edu.cn; Wen, Weiwei; Lu, Yuanrong; Guo, Zhiyu

    2016-07-01

    Peking University Neutron Imaging Facility (PKUNIFTY) works on an accelerator–based neutron source with a repetition period of 10 ms and pulse duration of 0.4 ms, which has a rather low Cd ratio. To improve the effective Cd ratio and thus improve the detection capability of the facility, energy-filtering neutron imaging was realized with the intensified CCD camera and time-of-flight (TOF) method. Time structure of the pulsed neutron source was firstly simulated with Geant4, and the simulation result was evaluated with experiment. Both simulation and experiment results indicated that fast neutrons and epithermal neutrons were concentrated in the first 0.8 ms of each pulse period; meanwhile in the period of 0.8–2.0 ms only thermal neutrons existed. Based on this result, neutron images with and without energy filtering were acquired respectively, and it showed that detection capability of PKUNIFTY was improved with setting the exposure interval as 0.8–2.0 ms, especially for materials with strong moderating capability.

  14. Improving differential die-away analysis via the use of neutron poisons in detectors

    International Nuclear Information System (INIS)

    Jordan, Kelly A.; Vujic, Jasmina; Phillips, Emmanuel; Gozani, Tsahi

    2007-01-01

    Differential Die-Away Analysis (DDAA) is an active interrogation technique to detect special nuclear material (SNM). In DDAA, a pulsed neutron generator produces pulses of neutrons that are directed into a cargo to be interrogated. As each pulse passes through the cargo, the neutrons are thermalized and absorbed. If SNM is present, the thermalized neutrons from the source will cause fissions that produce a new source of neutrons. The number of thermal neutrons decay exponentially with the diffusion decay time of the inspected medium, on the order of hundreds of μs. An external neutron detector which is designed to detect only epithermal neutrons, will measure only a single decaying exponential when there is no SNM present, and two exponentials when SNM is present. This paper shows that in many cases, a gain in detection sensitivity can be realized by introducing a thermal neutron poison (such as boron) into the detector. This poison will reduce the efficiency of the detector, but decrease its decay time. A decreased decay time will cause the separation between the detector and fission signal exponentials to occur at an earlier time. There is a balance between efficiency and time constant for a detector. The boron concentration to achieve the maximum sensitivity, and its magnitude, will be different for different detector designs

  15. Primary study for boron neutron capture therapy uses the RSG-GAS beam tube facility

    International Nuclear Information System (INIS)

    Suroso

    2000-01-01

    The minimum epithermal neutron flux as one of the prerequisite of Boron Neutron Capture Therapy (BNCT) is 1.0 x 10 9 n/(cm 2 s) RSG-GAS have 6 beam tube facilities for neutron source, which is one of the beam tube S-2 has a possibility to utilization for BNCT facility. The totally flux neutron measurement in the front of S-2 beam tube is 1.8 x 10 7 n/(cm 2 s). The neutron flux measurement was less than for BNCT minimum prerequisite. Concerning to the flux neutron production in the reactor, which is reach to 2.5 x 10 14 n/(cm 2 s), there for the S-2 beam tube could be used beside collimator modification

  16. Design study of a medical reactor for Boron Neutron Capture Therapy

    International Nuclear Information System (INIS)

    Sasaki, M.; Hirota, J.; Tamao, S.; Kanda, K.; Mishima, Y.

    1992-01-01

    A new design study of a medical reactor for Boron Neutron Capture Therapy (BNCT) has been carried out. The reactor is to be used exclusively for the treatment of malignant melanoma and other cancers as well as for the further biomedical research. Main specifications of the reactor are as follows; thermal power of 2 MW, water cooling by natural convection, semitight core of triangular lattice, UO 2 fuel rod of 9.5 mm diameter and no refueling in the reactor-life. Three horizontal and one vertical neutron beam hole are to be provided to deliver thermal and epithermal neutrons. N-γ coupling Sn transport calculations indicate that the patient treatment period will be about 30 minutes with minimal fast neutron and gamma contaminants. (author)

  17. Earth formation porosity log using measurement of neutron energy spectrum

    International Nuclear Information System (INIS)

    1981-01-01

    Methods and apparatus are described for measuring the porosity of subsurface earth formations in the vicinity of a well borehole by means of neutron well logging techniques. All the commercial techniques for measuring porosity currently available are not as accurate as desirable due to variations in the borehole wall diameter, in the borehole fluids (e.g. with chlorine content) in the casings of the borehole etc. This invention seeks to improve accuracy by using a measurement of the epithermal neutron population at one detector and the fast neutron population at a second detector, spaced approximately the same distance from a neutron source. The latter can be detected either by a fast neutron detector or indirectly by an inelastic gamma ray detector. Background correction can be made, and special detectors used, to discriminate against the detection of thermal neutrons or their resultant capture gamma rays. These fluctuations affect the measurement of thermal neutron populations. (U.K.)

  18. Development of Cold Neutron Activation Station at HANARO Cold Neutron Source

    International Nuclear Information System (INIS)

    Sun, G. M.; Hoang, S. M. T.; Moon, J. H.; Chung, Y. S.; Cho, S. J.; Lee, K. H.; Park, B. G.; Choi, H. D.

    2012-01-01

    A new cold neutron source at the HANARO Research Reactor had been constructed in the framework of a five-year project, and ended in 2009. It has seven neutron guides, among which five guides were already allocated for a number of neutron scattering instruments. A new two-year project to develop a Cold Neutron Activation Station (CONAS) was carried out at the two neutron guides since May 2010, which was supported by the program of the Ministry of Education, Science and Technology, Korea. Fig. 1 shows the location of CONAS. CONAS is a complex facility including several radioanalytical instruments utilizing neutron capture reaction to analyze elements in a sample. It was designed to include three instruments like a CN-PGAA (Cold Neutron - Prompt Gamma Activation Analysis), a CN-NIPS (Cold Neutron - Neutron Induced Pair Spectrometer), and a CN-NDP (Cold Neutron - Neutron-induced prompt charged particle Depth Profiling). Fig. 2 shows the conceptual configuration of the CONAS concrete bioshield and the instruments. CN-PGAA and CN-NIPS measure the gamma-rays promptly emitted from the sample after neutron capture, whereas CN-NDP is a probe to measure the charged particles emitted from the sample surface after neutron capture. For this, we constructed two cold neutron guides called CG1 and CG2B guides from the CNS

  19. Implementation of the k{sub 0} technique using multi-detectors on diverse irradiation facilities of TRIGA Reactor; Implementacion de la tecnica k{sub 0} usando multidetectores en diferentes instalaciones de irradiacion del Reactor TRIGA

    Energy Technology Data Exchange (ETDEWEB)

    Caldera C, M. de G.

    2013-07-01

    The k{sub 0} method with the technique of neutron activation analysis allows obtaining important characteristics parameters that describe a nuclear reactor. Among these parameters are the form factor of epithermal neutron flux, α and the ratio of thermal neutron flux with respect to the epithermal neutron flux, f. These parameters were obtained by irradiation of two different monitors, one of Au-Zr and the other of Au-Mo-Cr, where the last one was made and implemented for the first time. Both monitors were irradiated in different positions in the TRIGA Mark III Reactor at the National Institute of Nuclear Research. (Author)

  20. Implementation of the k0 technique using multi-detectors on diverse irradiation facilities of TRIGA Reactor

    International Nuclear Information System (INIS)

    Caldera C, M. de G.

    2013-01-01

    The k 0 method with the technique of neutron activation analysis allows obtaining important characteristics parameters that describe a nuclear reactor. Among these parameters are the form factor of epithermal neutron flux, α and the ratio of thermal neutron flux with respect to the epithermal neutron flux, f. These parameters were obtained by irradiation of two different monitors, one of Au-Zr and the other of Au-Mo-Cr, where the last one was made and implemented for the first time. Both monitors were irradiated in different positions in the TRIGA Mark III Reactor at the National Institute of Nuclear Research. (Author)

  1. Residual neutron-induced radionuclides in a soil sample collected in the vicinity of the criticality accident site in Tokai-mura, Japan: A Progress Report

    International Nuclear Information System (INIS)

    Nakanishi, Takashi; Hosotani, Risa; Komura, Kazuhisa; Muroyama, Toshiharu; Kofuji, Hisaki; Murata, Yoshimasa; Kimura, Shinzo; Kumar Sahoo, Sarata; Yonehara, Hidenori; Watanabe, Yoshito; Ban-nai, Tada-aki

    2000-01-01

    Residual neutron-induced radionuclides were measured in a soil sample collected in the vicinity of the location where a criticality accident occurred (in Tokai-mura, from 30 September to 1 October, 1999). Concentrations of 24 Na, 140 La, 122 Sb, 59 Fe, 124 Sb, 46 Sc, 65 Zn, 134 Cs and 60 Co in the soil sample were determined by γ-ray spectrometry, and neutron activation analysis was carried out for selected target elements in the sample. Tentative estimates of the apparent thermal and epithermal neutron fluences which reached the sample were obtained through combined analyses of 59 Fe/ 58 Fe, 124 Sb/ 123 Sb, 46 Sc/ 45 Sc, 65 Zn/ 64 Zn, 134 Cs/ 133 Cs and 60 Co/ 59 Co

  2. The PTB thermal neutron reference field at GeNF

    International Nuclear Information System (INIS)

    Boettger, R.; Friedrich, H.; Janssen, H.

    2004-01-01

    The experimental setup and procedure for the characterization of the thermal neutron reference field established at the Geesthacht neutron facility (GeNF) of the GKSS is described. The neutron beam, free in air, with a maximum flux of 10 6 s -1 , can easily be reduced to less than 10 4 s -1 by using a diaphragm variable in size and without changing the beam divergence. Also, the spectral distribution with a mean energy of 45 meV, measured by time-of-flight over a 6.6 m long flight path, is independent of the beam current chosen. In the 2002/2003 experiments reported here, a 6 Li glass detector was employed to determine the absolute beam current and to calibrate the 3 He transmission beam monitor. In addition, activation measurements of gold foils were carried out at a reduced beam divergence. The results agree within ±2%. Furthermore, the beam is characterized by a low gamma background intensity and a negligible fraction of epithermal neutrons. Irradiations in combination with a scanner device to achieve a homogeneously illuminated scan field have shown that the thermal beam is well suited for dosemeter development and for the calibration of radiation protection instruments. (orig.)

  3. The PTB thermal neutron reference field at GeNF

    Energy Technology Data Exchange (ETDEWEB)

    Boettger, R.; Friedrich, H.; Janssen, H.

    2004-07-01

    The experimental setup and procedure for the characterization of the thermal neutron reference field established at the Geesthacht neutron facility (GeNF) of the GKSS is described. The neutron beam, free in air, with a maximum flux of 10{sup 6} s{sup -1}, can easily be reduced to less than 10{sup 4} s{sup -1} by using a diaphragm variable in size and without changing the beam divergence. Also, the spectral distribution with a mean energy of 45 meV, measured by time-of-flight over a 6.6 m long flight path, is independent of the beam current chosen. In the 2002/2003 experiments reported here, a {sup 6}Li glass detector was employed to determine the absolute beam current and to calibrate the {sup 3}He transmission beam monitor. In addition, activation measurements of gold foils were carried out at a reduced beam divergence. The results agree within {+-}2%. Furthermore, the beam is characterized by a low gamma background intensity and a negligible fraction of epithermal neutrons. Irradiations in combination with a scanner device to achieve a homogeneously illuminated scan field have shown that the thermal beam is well suited for dosemeter development and for the calibration of radiation protection instruments. (orig.)

  4. Neutronics activities for next generation devices

    International Nuclear Information System (INIS)

    Gohar, Y.

    1985-01-01

    Neutronic activities for the next generation devices are the subject of this paper. The main activities include TFCX and FPD blanket/shield studies, neutronic aspects of ETR/INTOR critical issues, and neutronics computational modules for the tokamak system code and tandem mirror reactor system code. Trade-off analyses, optimization studies, design problem investigations and computational models development for reactor parametric studies carried out for these activities are summarized

  5. Experience of boron neutron capture therapy in Japan

    International Nuclear Information System (INIS)

    Kanda, K.

    2004-01-01

    Four research reactors are currently licensed for medical application in Japan. As of July 1995, approximately 210 clinical irradiations using these research reactors have been done for brain and skin tumors as shown. The number of chief medical doctors certified by the Government is eleven so far. Among them, eight doctors have already treated tumor patients using the Kyoto University Reactor (KUR, 5MW). Recently in USA clinical trials have been restarted using epithermal neutrons at MIT and BNL. In this paper, the experience of clinical trials of boron neutron capture therapy (BNCT) which have been performed in Japan, mainly physics studies, are reviewed, and current studies are also introduced

  6. Determination of the neutron spectrum in the well Naiade attached to the reactor Nereide

    International Nuclear Information System (INIS)

    Capgras, Andree; Clement, Christophe; Sueur, Maurice.

    1977-11-01

    The spectral distribution of neutrons in the centre of the well Naiade attached to the Fontenay-aux-Roses reactor Nereide is studied. In the thermal, epithermal and over 2.2 MeV regions, activation detectors are used: 197 Au and 55 Mn (bare and under cadmium), and 58 Ni. In the energy band from a few keV to 2.2 MeV two recoil proton proportional counters are employed. Under these conditions the whole spectrum is studied, but some comments are made on the difficulties of interpreting the results obtained by either of these methods [fr

  7. Comparison between different flux traps assembled in the core of the nuclear reactor IPEN/MB-01 by measuring of the thermal and epithermal neutron fluxes using activation foils

    International Nuclear Information System (INIS)

    Mura, Luiz Ernesto Credidio; Bitelli, Ulysses d'Utra; Mura, Luis Felipe Liambos; Carluccio, Thiago; Andrade, Graciete Simoes de

    2011-01-01

    The production of radioisotopes is one of the most important applications of nuclear research reactors. This study investigated a method called Flux Trap, which is used to increase the yield of production of radioisotopes in nuclear reactors. The method consists in the rearrangement of the fuel rods to allow the increase of the thermal neutron flux in the irradiation region inside the reactor core, without changing the standard reactor power level. Various configurations were assembled with the objective of finding the configuration with the highest thermal neutron flux in the region of irradiation. The method of activation analysis was used to measure the thermal neutron flux and determine the most efficient reactor core configuration . It was found that there was an increase in the thermal neutron flux of 337% in the most efficient configuration, which demonstrates the effectiveness of the method. (author)

  8. Atmospheric deposition of heavy metals in Serbia studied by moss biomonitoring, neutron activation analysis and GIS technology

    International Nuclear Information System (INIS)

    Frontas'eva, M.V.; Galinskaya, T.E.; Pavlov, S.S.; Kumar, M.; Matavuly, M.; Radnovic, D.; Steinnes, E.

    2002-01-01

    The results of a pilot study on atmospheric deposition of heavy metals and other trace elements using the moss biomonitoring technique in the northern part of Serbia and some areas of Bosnia are presented. Samples of Hypnum cupressiforme along with some other moss types were collected at 92 sites during the summer of 2000. A total of 44 elements were determined by instrumental neutron activation analysis using epithermal neutrons. The observed levels of Cu, Zn, As, Ag, Cd, In, Sb, etc. in the area surrounding the town of Bor (Serbia) are comparable to those reported from similar industrial areas in other countries such as the Copper Basin in Poland and the South Urals of Russia. In the same region the maximum Se and Mo concentrations are the highest ever recorded in biomonitoring studies using mosses. High median concentrations of Fe and Ni in Serbian mosses are associated with a crustal component as apparent from factor analysis of the moss data. This component could be a result of windblown soil dust (most of the samples were taken from agricultural regions) or deposition of ash from coal-burning power stations. Some specific elements such as Cl and V may originate from known industrial sources, but at certain places high values in the moss samples are suspected to be associated with fires in oil refineries damaged during the 1999 NATO military action

  9. Measurements of fusion neutron yields by neutron activation technique: Uncertainty due to the uncertainty on activation cross-sections

    Energy Technology Data Exchange (ETDEWEB)

    Stankunas, Gediminas, E-mail: gediminas.stankunas@lei.lt [Lithuanian Energy Institute, Laboratory of Nuclear Installation Safety, Breslaujos str. 3, LT-44403 Kaunas (Lithuania); EUROfusion Consortium, JET, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Batistoni, Paola [ENEA, Via E. Fermi, 45, 00044 Frascati, Rome (Italy); EUROfusion Consortium, JET, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Sjöstrand, Henrik; Conroy, Sean [Department of Physics and Astronomy, Uppsala University, PO Box 516, SE-75120 Uppsala (Sweden); EUROfusion Consortium, JET, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)

    2015-07-11

    The neutron activation technique is routinely used in fusion experiments to measure the neutron yields. This paper investigates the uncertainty on these measurements as due to the uncertainties on dosimetry and activation reactions. For this purpose, activation cross-sections were taken from the International Reactor Dosimetry and Fusion File (IRDFF-v1.05) in 640 groups ENDF-6 format for several reactions of interest for both 2.5 and 14 MeV neutrons. Activation coefficients (reaction rates) have been calculated using the neutron flux spectra at JET vacuum vessel, both for DD and DT plasmas, calculated by MCNP in the required 640-energy group format. The related uncertainties for the JET neutron spectra are evaluated as well using the covariance data available in the library. These uncertainties are in general small, but not negligible when high accuracy is required in the determination of the fusion neutron yields.

  10. Hydrogen content in Zircaloy-IV by neutron emissions

    International Nuclear Information System (INIS)

    Granada, J.R.

    1991-01-01

    The feasibility of using thermal neutron transmission techniques to determine the initial hydrogen content in Zry-IV is discussed in this work. The usual conditions of very low H concentration (∼ 10-20 ppm in weight) in the alloy, require a high degree of accuracy in the relevant cross sections in order to obtain reliable values of that concentration from the measured transmission spectra. Total cross sections corresponding to the metallic alloy and to hydrogen in that matrix were evaluated using interaction models developed in this Laboratory, for neutrons covering the range from subthermal up to epithermal energies. The sensitivity of this method as a function of neutron energy is discussed, and an optimized and self consistent procedure for data analysis after a transmission experiment is proposed. (Author) [es

  11. Single-crystal filters for attenuating epithermal neutrons and gamma rays in reactor beams

    DEFF Research Database (Denmark)

    Rustad, B.M.; Als-Nielsen, Jens Aage; Bahnsen, A.

    1965-01-01

    Cross section of representative samples of bismuth and quartz were measured at room and liquid nitrogen temperatures over neutron energy range of 0.0007 to 2.0 ev to obtain data for design of single-crystal 32-cm bismuth filters for attenuating fast neutrons and γ-rays in reactor beams; filters may...

  12. Beam shaping assembly of a D-T neutron source for BNCT and its dosimetry simulation in deeply-seated tumor

    Science.gov (United States)

    Faghihi, F.; Khalili, S.

    2013-08-01

    This article involves two aims for BNCT. First case includes a beam shaping assembly estimation for a D-T neutron source to find epi-thermal neutrons which are the goal in the BNCT. Second issue is the percent depth dose calculation in the adult Snyder head phantom. Monte-Carlo simulations and verification of a suggested beam shaping assembly (including internal neutron multiplier, moderator, filter, external neutron multiplier, collimator, and reflector dimensions) for thermalizing a D-T neutron source as well as increasing neutron flux are carried out and our results are given herein. Finally, we have simulated its corresponding doses for treatment planning of a deeply-seated tumor.

  13. Forensic neutron activation analysis

    International Nuclear Information System (INIS)

    Kishi, T.

    1987-01-01

    The progress of forensic neutron activation analysis (FNAA) in Japan is described. FNAA began in 1965 and during the past 20 years many cases have been handled; these include determination of toxic materials, comparison examination of physical evidences (e.g., paints, metal fragments, plastics and inks) and drug sample differentiation. Neutron activation analysis is applied routinely to the scientific criminal investigation as one of multielement analytical techniques. This paper also discusses these routine works. (author) 14 refs

  14. Neutron resonances in the compound nucleus: Parity nonconservation to dynamic temperature measurements

    International Nuclear Information System (INIS)

    Yuan, V.W.

    1997-08-01

    Experiments using epithermal neutrons that interact to form compound-nuclear resonances serve a wide range of scientific applications. Changes in transmission which are correlated to polarization reversal in incident neutrons have been used to study parity nonconservation in the compound nucleus for a wide range of targets. The ensemble of measured parity asymmetries provides statistical information for the extraction of the rms parity-violating mean-square matrix element as a function of mass. Parity nonconservation in neutron resonances can also be used to determine the polarization of neutron beams. Finally the motion of target atoms results in an observed temperature-dependent Doppler broadening of resonance line widths. This broadening can be used to determine temperatures on a fast time scale of one microsecond or less

  15. Physical basis for prompt-neutron activation analysis

    International Nuclear Information System (INIS)

    Chrien, R.E.

    1982-01-01

    The technique called prompt ν-ray neutron activation analysis has been applied to rapid materials analysis. The radiation following the neutron radiation capture is prompt in the sense that the nuclear decay time is on the order of 10 - 15 second, and thus the technique is not strictly activation, but should be called radiation neutron capture spectroscopy or neutron capture ν-ray spectroscopy. This paper reviews the following: sources and detectors, theory of radiative capture, nonstatistical capture, giant dipole resonance, fast neutron capture, and thermal neutron capture ν-ray spectra. 14 figures

  16. Evaluation of response function of moderating-type neutron detector and application to environmental neutron measurement

    International Nuclear Information System (INIS)

    Kosako, Toshiso; Nakamura, Takashi; Iwai, Satoshi; Katsuki, Shinji; Kamata, Masashi.

    1983-08-01

    The energy-dependent response function of a multi-cylinder moderating-type BF 3 counter, so-called Bonner counter, was calculated by the time-dependent multi-group Monte Carlo code, TMMCR. The calculated response function was evaluated experimentally for neutron energy below about 50 keV down to epithermal energy by the time-of-flight method combining with a large lead pile at the Nuclear Engineering Research Laboratory, University of Tokyo and also above 50 keV by using the monoenergetic neutron standard field a t the Electrotechnical Laboratory. The time delay in the polyethylene moderator of the Bonner counter due to multiple collisions with hydrogen was analyzed by the TMMCR code and used for the time-spectrum analysis of the time-of-flight measurement. The response function obtained by these two experiments showed good agreement with the calculated results. This Bonner counter having a response function evaluated from thermal to MeV energy range was used for spectrometry and dosimetry of environmental neutrons around some nuclear facilities. The neutron spectra and dose measured in the environment around a 252 Cf fission source, fast neutron source reactor and electron synchrotron were all in good agreement with the calculated results and the measured results with other neutron detectors. (author)

  17. Geochemical and modal data for igneous rocks associated with epithermal mineral deposits

    Science.gov (United States)

    du Bray, Edward A.

    2014-01-01

    The purposes of this report are to (1) present available geochemical and modal data for igneous rocks associated with epithermal mineral deposits and (2) to make those data widely and readily available for subsequent, more in-depth consideration and interpretation. Epithermal precious and base-metal deposits are commonly associated with subduction-related calc-alkaline to alkaline arc magmatism as well as back-arc continental rift magmatism. These deposits form in association with compositionally diverse extrusive and intrusive igneous rocks. Temperature and depth regimes prevailing during deposit formation are highly variable. The deposits form from hydrothermal fluids that range from acidic to near-neutral pH, and they occur in a variety of structural settings. The disparate temperature, pressure, fluid chemistry, and structural controls have resulted in deposits with wide ranging characteristics. Economic geologists have employed these characteristics to develop classification schemes for epithermal deposits and to constrain the important genetic processes responsible for their formation.

  18. Neutron-induced gamma-ray spectroscopy: simulations for chemical mapping of planetary surfaces

    International Nuclear Information System (INIS)

    Brueckner, J.; Waenke, H.; Reedy, R.C.

    1986-01-01

    Cosmic rays interact with the surface of a planetary body and produce a cascade of secondary particles, such as neutrons. Neutron-induced scattering and capture reactions play an important role in the production of discrete gamma-ray lines that can be measured by a gamma-ray spectrometer on board of an orbiting spacecraft. These data can be used to determine the concentration of many elements in the surface of a planetary body, which provides clues to its bulk composition and in turn to its origin and evolution. To investigate the gamma rays made by neutron interactions, thin targets were irradiated with neutrons having energies from 14 MeV to 0.025 eV. By means of foil activation technique the ratio of epithermal to thermal neutrons was determined to be similar to that in the Moon. Gamma rays emitted by the targets and the surrounding material were detected by a high-resolution germanium detector in the energy range of 0.1 to 8 MeV. Most of the gamma-ray lines that are expected to be used for planetary gamma-ray spectroscopy were found in the recorded spectra and the principal lines in these spectra are presented. 58 refs., 7 figs., 9 tabs

  19. A target-moderator-reflector concept of the JAERI 5 MW pulsed spallation neutron source

    International Nuclear Information System (INIS)

    Watanabe, Noboru; Teshigawara, Makoto; Aizawa, Kazuya; Suzuki, Jyunichi; Oyama, Yukio

    1998-03-01

    In Japan Atomic Energy Research Institute the construction of a 5 MW (short) pulsed spallation neutron source is under planning using a projected high power superconducting proton (or H - ) linac of 8 MW in total beam power. In the present paper we report our consideration on target-moderator-reflector concept, based on the layout of the tentative neutron instruments for the assumed neutron scattering experiments in future. The choice of cold neutron moderators for high resolution and high intensity experiments, thermal and epithermal neutron moderators for high resolution uses was discussed and a reference layout of target-moderator-reflector system was proposed for detailed neutronic calculation and optimization. The proposed system was designed like that it can provide, at least, 30 beam lines for more than 40 instruments. (author)

  20. Effects of secondary interactions on the dose calculation in treatments with Boron Neutron Capture Therapy (BNCT)

    International Nuclear Information System (INIS)

    Monteiro, E.

    2004-01-01

    The aimed of this work consists of evaluating the influence of the secondary contributions of dose (thermal neutrons dose, epithermal neutrons dose, fast neutrons dose and photon dose) in treatment planning with BNCT. MCNP4B Code was used to calculate RBE-Gy doses through the irradiation of the modified Snyder head head phantom.A reduction of the therapeutical gain of monoenergetic neutron beans was observed in non invasive treatments, provoked for the predominance of the fast neutron dose component in the skin, showing that the secondary contributions of dose can contribute more in the direction to raise the dose in the fabric healthy that in the tumor, thus reducing the treatment efficiency. (author)

  1. Characterisation of an accelerator-based neutron source for BNCT versus beam energy

    Science.gov (United States)

    Agosteo, S.; Curzio, G.; d'Errico, F.; Nath, R.; Tinti, R.

    2002-01-01

    Neutron capture in 10B produces energetic alpha particles that have a high linear energy transfer in tissue. This results in higher cell killing and a higher relative biological effectiveness compared to photons. Using suitably designed boron compounds which preferentially localize in cancerous cells instead of healthy tissues, boron neutron capture therapy (BNCT) has the potential of providing a higher tumor cure rate within minimal toxicity to normal tissues. This clinical approach requires a thermal neutron source, generally a nuclear reactor, with a fluence rate sufficient to deliver tumorcidal doses within a reasonable treatment time (minutes). Thermal neutrons do not penetrate deeply in tissue, therefore BNCT is limited to lesions which are either superficial or otherwise accessible. In this work, we investigate the feasibility of an accelerator-based thermal neutron source for the BNCT of skin melanomas. The source was designed via MCNP Monte Carlo simulations of the thermalization of a fast neutron beam, generated by 7 MeV deuterons impinging on a thick target of beryllium. The neutron field was characterized at several deuteron energies (3.0-6.5 MeV) in an experimental structure installed at the Van De Graaff accelerator of the Laboratori Nazionali di Legnaro, in Italy. Thermal and epithermal neutron fluences were measured with activation techniques and fast neutron spectra were determined with superheated drop detectors (SDD). These neutron spectrometry and dosimetry studies indicated that the fast neutron dose is unacceptably high in the current design. Modifications to the current design to overcome this problem are presented.

  2. Self-powered detectors sensitivity determination

    International Nuclear Information System (INIS)

    Surkov, V.; Soares, A.J.

    1994-01-01

    The determination of the initial sensitivity of Self Powered Detectors (SPDs) was performed. Measurements of thermal, epithermal and to gamma flux sensitivities were made with Vanadium, Cobalt, Rhodium, Silver and Platinum SPDs and, when possible, the values are compared with the ones from the existing literature. The determination of neutron sensitivity was realized using the IEA-R1 Reactor from IPEN. The thermal and epithermal neutron flux were determined with bare and Cadmium covered activation foils. (GOLD). (author)

  3. Evidence for rapid epithermal mineralization and coeval bimodal volcanism, Bruner Au-Ag property, NV USA

    Science.gov (United States)

    Baldwin, Dylan

    The character of Au-Ag mineralization and volcanic/hydrothermal relationships at the underexplored Miocene-age Bruner low-sulfidation epithermal Au-Ag deposit are elucidated using field and laboratory studies. Bruner is located in central Nevada within the Great Basin extensional province, near several major volcanic trends (Western Andesite, Northern Nevada Rift) associated with world-class Miocene-age epithermal Au-Ag provinces. Despite its proximity to several >1 Moz Au deposits, and newly discovered high-grade drill intercepts (to 117 ppm Au/1.5m), there is no published research on the deposit, the style of mineralization has not been systematically characterized, and vectors to mineralization remain elusive. By investigating the nature of mineralization and time-space relationships between volcanic/hydrothermal activity, the deposit has been integrated into a regional framework, and exploration targeting improved. Mineralization occurs within narrow quartz + adularia +/- pyrite veins that manifest as sheeted/stockwork zones, vein swarms, and rare 0.3-2 m wide veins hosted by two generations of Miocene high-K, high-silica rhyolite flow dome complexes overlying an andesite flow unit. The most prominent structural controls on veining are N­striking faults and syn-mineral basalt/rhyolite dikes. Productive veins have robust boiling indicators (high adularia content, bladed quartz after calcite, recrystallized colloform quartz bands), lack rhythmic banding, and contain only 1-2 stages; these veins overprint, or occur separately from another population of barren to weakly mineralized rhythmically banded quartz-only veins. Ore minerals consist of coarse Au0.5Ag 0.5 electrum, fine Au0.7Ag0.3 electrum, acanthite, uytenbogaardtite (Ag3AuS2) and minor embolite Ag(Br,Cl). Now deeply oxidized, veins typically contain Bruner appears to belong to a small subset of mid-Miocene epithermal deposits in Nevada with low base metal contents and low to no Se, related to calc

  4. Neutron activation analysis at the Californium User Facility for Neutron Science

    International Nuclear Information System (INIS)

    Martin, R.C.; Smith, E.H.; Glasgow, D.C.; Jerde, E.A.; Marsh, D.L.; Zhao, L.

    1997-12-01

    The Californium User Facility (CUF) for Neutron Science has been established to provide 252 Cf-based neutron irradiation services and research capabilities including neutron activation analysis (NAA). A major advantage of the CUF is its accessibility and controlled experimental conditions compared with those of a reactor environment The CUF maintains the world's largest inventory of compact 252 Cf neutron sources. Neutron source intensities of ≤ 10 11 neutrons/s are available for irradiations within a contamination-free hot cell, capable of providing thermal and fast neutron fluxes exceeding 10 8 cm -2 s -1 at the sample. Total flux of ≥10 9 cm -2 s -1 is feasible for large-volume irradiation rabbits within the 252 Cf storage pool. Neutron and gamma transport calculations have been performed using the Monte Carlo transport code MCNP to estimate irradiation fluxes available for sample activation within the hot cell and storage pool and to design and optimize a prompt gamma NAA (PGNAA) configuration for large sample volumes. Confirmatory NAA irradiations have been performed within the pool. Gamma spectroscopy capabilities including PGNAA are being established within the CUF for sample analysis

  5. Neutron Activation Analysis with k0-standardisation

    International Nuclear Information System (INIS)

    Pomme, S.

    2001-01-01

    SCK-CEN's programme on Neutron Activation Analysis with k 0 -standardisation concentrates on the improvement of the standardisation method and the characterisation of the neutron field as well as on the improvement of the statistical control on neutron activation analysis. Main achievements in 2000 are reported

  6. Deriving profiles of incident and scattered neutrons for TOF experiments with the spallation sources

    International Nuclear Information System (INIS)

    Watanabe, Hidehiro

    1993-01-01

    A formula that closely matches the incident profile of epi-thermal and thermal neutrons for time of flight experiments carried out with a spallation neutron source and moderator scheme is derived based on the slowing-down and diffusing-out processes in a moderator. This analytical description also enables us to predict burst-function profiles; these profiles are verified by a comparison with a diffraction pattern. The limits of the analytical model are discussed through the predictable peak position shift brought about by the slowing-down process. (orig.)

  7. Measurement of reaction cross sections of {sup 129}I induced by DT neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, Daisuke; Murata, Isao; Takahashi, Akito [Osaka Univ., Suita (Japan). Faculty of Engineering

    1997-03-01

    The cross sections were measured for the {sup 129}I(n,2n){sup 128}I and {sup 129}I(n,{gamma}){sup 130}I reactions by DT neutrons, at OKTAVIAN facility of Osaka University, Japan. The foil activation method was used in the measurement. The sample was a sealed source of {sup 129}I, which was covered with a Cd foil. The irradiations were performed for 75 minutes to obtain the cross section of reaction producing {sup 128}I (T{sub 1/2}=24.99m) and 22 hours for the {sup 130}I (T{sub 1/2}=12.36h), respectively. The gamma-rays emitted from the irradiated sample were measured with a high purity Ge detector. The measured cross sections of {sup 129}I(n,2n){sup 128}I and {sup 129}I(n,{gamma}){sup 130}I reactions were 0.92{+-}0.11 barn and 0.013{+-}0.002 barn, respectively. For the {sup 129}I(n,2n){sup 128}I reaction, the evaluation of JENDL-3.2 overestimates cross section about 60% to the experimental result. However, especially for the {sup 129}I(n,{gamma}) reaction, the measured cross section may include the contribution from the neutrons in MeV region as well as epithermal ones. Also, the obtained cross section of the {sup 129}I(n,{gamma}){sup 130}I reaction was evaluated as an effective production cross section of {sup 130}I including {sup 129}I(n,{gamma}){sup 130m}I reaction. In order to remove the contribution from the epithermal and MeV region neutrons. A new method was proposed for the measurement of (n,{gamma}) reaction cross section. (author)

  8. The synchronous active neutron detection assay system

    International Nuclear Information System (INIS)

    Pickrell, M.M.; Kendall, P.K.

    1994-01-01

    We have begun to develop a novel technique for active neutron assay of fissile material in spent nuclear fuel. This approach will exploit a 14-MeV neutron generator developed by Schlumberger. The technique, termed synchronous active neutron detection (SAND), follows a method used routinely in other branches of physics to detect very small signals in presence of large backgrounds. Synchronous detection instruments are widely available commercially and are termed ''lock-in'' amplifiers. We have implemented a digital lock-in amplifier in conjunction with the Schlumberger neutron generator to explore the possibility of synchronous detection with active neutrons. The Schlumberger system can operate at up to a 50% duty factor, in effect, a square wave of neutron yield. Results are preliminary but promising. The system is capable of resolving the fissile material contained in a small fraction of the fuel rods in a cold fuel assembly; it also appears resilient to background neutron interference. The interrogating neutrons appear to be non-thermal and penetrating. Work remains to fully explore relevant physics and optimize instrument design

  9. Thermal neutron capture and resonance integral cross sections of {sup 45}Sc

    Energy Technology Data Exchange (ETDEWEB)

    Van Do, Nguyen; Duc Khue, Pham; Tien Thanh, Kim [Institute of Physics, Vietnam Academy of Science and Technology, 10 Dao Tan, Hanoi (Viet Nam); Thi Hien, Nguyen [Institute of Physics, Vietnam Academy of Science and Technology, 10 Dao Tan, Hanoi (Viet Nam); Department of Physics and Center for High Energy Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Kim, Guinyun, E-mail: gnkim@knu.ac.kr [Department of Physics and Center for High Energy Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Kim, Kwangsoo [Department of Physics and Center for High Energy Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Shin, Sung-Gyun; Cho, Moo-Hyun [Department of Advanced Nuclear Engineering, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Lee, Manwoo [Research Center, Dongnam Institute of Radiological and Medical Science, Busan 619-953 (Korea, Republic of)

    2015-11-01

    The thermal neutron cross section (σ{sub 0}) and resonance integral (I{sub 0}) of the {sup 45}Sc(n,γ){sup 46}Sc reaction have been measured relative to that of the {sup 197}Au(n,γ){sup 198}Au reaction by means of the activation method. High-purity natural scandium and gold foils without and with a cadmium cover of 0.5 mm thickness were irradiated with moderated pulsed neutrons produced from the Pohang Neutron Facility (PNF). The induced activities in the activated foils were measured with a high purity germanium (HPGe) detector. In order to improve the accuracy of the experimental results the counting losses caused by the thermal (G{sub th}) and resonance (G{sub epi}) neutron self-shielding, the γ-ray attenuation (F{sub g}) and the true γ-ray coincidence summing effects were made. In addition, the effect of non-ideal epithermal spectrum was also taken into account by determining the neutron spectrum shape factor (α). The thermal neutron cross-section and resonance integral of the {sup 45}Sc(n,γ){sup 46}Sc reaction have been determined relative to the reference values of the {sup 197}Au(n,γ){sup 198}Au reaction, with σ{sub o,Au} = 98.65 ± 0.09 barn and I{sub o,Au} = 1550 ± 28 barn. The present thermal neutron cross section has been determined to be σ{sub o,Sc} = 27.5 ± 0.8 barn. According to the definition of cadmium cut-off energy at 0.55 eV, the present resonance integral cross section has been determined to be I{sub o,Sc} = 12.4 ± 0.7 barn. The present results are compared with literature values and discussed.

  10. The background cross section method for calculating the epithermal neutron spectra

    International Nuclear Information System (INIS)

    Martinez, A.S.

    1983-01-01

    We have developed a new methodology to the multigroup constants calculations, for thermal and fast reactors. The method to obtain the constants is extremely fast and simple, and it avoid repeated computations of the detailed neutron spectrum for different cell configurations (composition, geometry and temperature). (author) [pt

  11. Pulsed neutron generator for logging

    International Nuclear Information System (INIS)

    Thibideau, F.D.

    1977-01-01

    A pulsed neutron generator for uranium logging is described. This generator is one component of a prototype uranium logging probe which is being developed by SLA to detect, and assay, uranium by borehole logging. The logging method is based on the measurement of epithermal neutrons resulting from the prompt fissioning of uranium from a pulsed source of 17.6 MeV neutrons. An objective of the prototype probe was that its diameter not exceed 2.75 inches, which would allow its use in conventional rotary drill holes of 4.75-inch diameter. This restriction limited the generator to a maximum 2.375-inch diameter. The performance requirements for the neutron generator specified that it operate with a nominal output of 5 x 10 6 neutrons/pulse at up to 100 pulses/second for a one-hour period. The development of a neutron generator meeting the preliminary design goals was completed and two prototype models were delivered to SLA. These two generators have been used by SLA to log a number of boreholes in field evaluation of the probe. The results of the field evaluations have led to the recommendation of several changes to improve the probe's operation. Some of these changes will require additional development effort on the neutron generator. It is expected that this work will be performed during 1977. The design and operation of the first prototype neutron generators is described

  12. Design considerations for epithermal pulse reactors

    International Nuclear Information System (INIS)

    Ostensen, R.W.

    1978-01-01

    Simplified design criteria were developed for scoping analyses of epithermal pulse reactors for use in LMFBR safety testing. By using these criteria, materials and designs were investigated to determine performance limits of moderately sized reactor cores. Several designs are suggested for further study. These are a gas-cooled core fueled with a heterogeneous mixture of Fe-UO 2 cermet and BeO-UO 2 ceramic fuels, and a heavy-water-cooled core fueled with an Fe-UO 2 cermet

  13. Accurate measurements of neutron activation cross sections

    International Nuclear Information System (INIS)

    Semkova, V.

    1999-01-01

    The applications of some recent achievements of neutron activation method on high intensity neutron sources are considered from the view point of associated errors of cross sections data for neutron induced reaction. The important corrections in -y-spectrometry insuring precise determination of the induced radioactivity, methods for accurate determination of the energy and flux density of neutrons, produced by different sources, and investigations of deuterium beam composition are considered as factors determining the precision of the experimental data. The influence of the ion beam composition on the mean energy of neutrons has been investigated by measurement of the energy of neutrons induced by different magnetically analysed deuterium ion groups. Zr/Nb method for experimental determination of the neutron energy in the 13-15 MeV energy range allows to measure energy of neutrons from D-T reaction with uncertainty of 50 keV. Flux density spectra from D(d,n) E d = 9.53 MeV and Be(d,n) E d = 9.72 MeV are measured by PHRS and foil activation method. Future applications of the activation method on NG-12 are discussed. (author)

  14. Resonant neutron-induced atomic displacements

    Energy Technology Data Exchange (ETDEWEB)

    Elmaghraby, Elsayed K., E-mail: e.m.k.elmaghraby@gmail.com

    2017-05-01

    Highlights: • Neutron induced atomic displacements was investigated based on scattering of energy of neutron. • Model for cascade function (multiplication of displacements with increasing energy transfer) was proposed and justified. • Parameterizations for the dpa induced in all elements were performed. • Table containing all necessary parameters to calculate the displacement density induced by neutron is given. • Contribution of non resonance displacement and resonant-neutron induced displacements are distinguished. - Abstract: A model for displacement cascade function was modified to account for the continuous variation of displacement density in the material in response to neutron exposure. The model is based on the Gaussian distribution of displacement energies of atoms in a material. Analytical treatment for moderated epithermal neutron field was given in which the displacement density was divided into two terms, discrete-resonance term and continuum term. Calculation are done for all isotopes using ENDF/B VII.1 data files and temperature dependent cross section library. Weighted elemental values were reported a fitting was performed to obtain energy-dependent formula of displacement density and reduce the number of parameters. Results relevant the present specification of the cascade function are tabulated for each element to enable calculation of displacement density at any value of displacement energy in the between 5 eV and 55 eV.

  15. Estimation of "9"9Mo production rates from natural molybdenum in research reactors

    International Nuclear Information System (INIS)

    Blaauw, M.; Chakrova, Y.; Jacimovic, R.; Kling, A.

    2017-01-01

    Molybdenum-99 is one of the most important radionuclides for medical diagnostics. In 2015, the International Atomic Energy Agency organized a round-robin exercise where the participants measured and calculated specific saturation activities achievable for the "9"8Mo(n,γ)"9"9Mo reaction. This reaction is of interest as a means to locally, and on a small scale, produce "9"9Mo from natural molybdenum. The current paper summarises a set of experimental results and reviews the methodology for calculating the corresponding saturation activities. Activation by epithermal neutrons and also epithermal neutron self-shielding are found to be of high importance in this case. (author)

  16. Using MCNP-4C code for design of the thermal neutron beam for neutron radiography at the MNSR

    International Nuclear Information System (INIS)

    Shaaban, I.

    2009-11-01

    Studies were carried out for determination of the parameters of a thermal neutron beam at the MNSR reactor (MNSR-30 kW) for neutron radiography in the vertical beam port by using the MCNP-4C (Monte Carlo Neutron - Photon transport). Thermal, epithermal and fast neutron energy ranges were selected as 10 keV respectively. To produce a good neutron beam in terms of intensity and quality, several materials Lead (Pb), Bismuth (Bi), Borated polyethelyene and Alumina Oxide (Al 2 O 3 ) were used as neutron and photon filters. Based on the current design, the L/D of the facility ranges between 125, 110 and 90. The thermal neutron flux at the beam exit is 1.436x10 5 n/cm2 .s ,1.843x10 5 n/cm2 .s and 2.845x10 5 n/cm2 .s respectively, middots with a Cd-ratio of ∼ 2.829, 2.766, 3.191 for the L/D = 125, 110, 90 respectively. The estimated values for gamma doses are 6.705x10 -2 Rem/h and 1.275x10 -1 Rem/h and 2.678x10 -1 Rem/ h with bismuth. The divergent angle of the collimator is 1.348 degree - 2.021 degree. Such neutron beams, if built into the Syrian MNSR reactor, could support the application of NRG in Syria. (author)

  17. Design considerations for neutron activation and neutron source strength monitors for ITER

    International Nuclear Information System (INIS)

    Barnes, C.W.; Jassby, D.L.; LeMunyan, G.; Roquemore, A.L.

    1997-01-01

    The International Thermonuclear Experimental Reactor will require highly accurate measurements of fusion power production in time, space, and energy. Spectrometers in the neutron camera could do it all, but experience has taught us that multiple methods with redundancy and complementary uncertainties are needed. Previously, conceptual designs have been presented for time-integrated neutron activation and time-dependent neutron source strength monitors, both of which will be important parts of the integrated suite of neutron diagnostics for this purpose. The primary goals of the neutron activation system are: to maintain a robust relative measure of fusion energy production with stability and wide dynamic range; to enable an accurate absolute calibration of fusion power using neutronic techniques as successfully demonstrated on JET and TFTR; and to provide a flexible system for materials testing. The greatest difficulty is that the irradiation locations need to be close to plasma with a wide field of view. The routing of the pneumatic system is difficult because of minimum radius of curvature requirements and because of the careful need for containment of the tritium and activated air. The neutron source strength system needs to provide real-time source strength vs. time with ∼1 ms resolution and wide dynamic range in a robust and reliable manner with the capability to be absolutely calibrated by in-situ neutron sources as done on TFTR, JT-60U, and JET. In this paper a more detailed look at the expected neutron flux field around ITER is folded into a more complete design of the fission chamber system

  18. Evaluation of JRR-4 neutron beam using tumor cells

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Kazuyoshi; Kumada, Hiroaki; Torii, Yoshiya; Kishi, Toshiaki; Horiguchi, Yoji [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Yamamoto, Tetsuya; Matsumura, Akira; Nose, Tadao [Tsukuba Univ., Ibaraki (Japan)

    2001-03-01

    For preparation of irradiation plan of boron-neutron capture therapy (BNCT), not only the physical dose is important, but also weighted factors or RBE are also necessary on the evaluation of the effect on the organism. Physical dose calculated by dose evaluation system (JCDS : JAERI Computational Dosimetry System) must appropriately carry out the weighting by various cells like tumor, central nerve, glia, and the vascular in proportion to JRR-4 each irradiation mode. In-vitro biological experiment which used 9L gliosarcoma and C6 glioma in the head water phantom was carried out in order to evaluate these effect. Neutron beam characteristics of JRR-4 were also evaluated from the functions of survival fraction of these cells. As a result of the evaluation, it became clear that the dose evaluation calculated from physical dose of the boron and nitrogen carried out in traditional BNCT of Japan using thermal neutron is applicable for thermal and epi-thermal mixed neutron beam. (author)

  19. Proceedings of national seminar neutron activation analysis

    International Nuclear Information System (INIS)

    Agus Taftazani; Muhayatun Santoso; Budi Haryanto; Khatarina Oginawati

    2010-11-01

    Proceedings of national seminar neutron activation analysis in 2010 with the theme of the Role of Nuclear Analytical Techniques in the Field of Environment, Health and Industry. The seminar was organized by Indonesians Neutron Activation Analysis and BATAN Forum. These proceedings contain the result of environmental research in BATAN, universities and institutions associated with the application on neutron activation analysis technique. The purpose of these proceedings was as a useful source of information to spur research and development of activation analysis applications in various fields for the Indonesian welfare. There are 40 articles. (PPIKSN).

  20. Epithermal gold occurrences in the lakes district of the Main ...

    African Journals Online (AJOL)

    MER). Epithermal gold occurrences related to Quaternary volcanics are at present being closely studied for their precious metal potential. Low sulphidation (Adularia-sericite-type) occurrences have been found. Analyses of 579 core and cutting ...