  1. Optimal Implantable Cardioverter Defibrillator Programming.

    Science.gov (United States)

    Shah, Bindi K

    Optimal programming of implantable cardioverter defibrillators (ICDs) is essential to appropriately treat ventricular tachyarrhythmias and to avoid unnecessary and inappropriate shocks. There have been a series of large clinical trials evaluating tailored programming of ICDs. We reviewed the clinical trials evaluating ICD therapies and detection, and the consensus statement on ICD programming. In doing so, we found that prolonged ICD detection times, higher rate cutoffs, and antitachycardia pacing (ATP) programming decreases inappropriate and painful therapies in a primary prevention population. The use of supraventricular tachyarrhythmia discriminators can also decrease inappropriate shocks. Tailored ICD programming using the knowledge gained from recent ICD trials can decrease inappropriate and unnecessary ICD therapies and decrease mortality.

  2. Concerns about the implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van Domburg, Ron T; Theuns, Dominic A M J

    2005-01-01

    Patients with an implantable cardioverter defibrillator (ICD) are at increased risk of anxiety disorders. In turn, anxiety has been identified as a precipitant of ventricular arrhythmias. Anxiety may in part be attributed to concerns about the ICD firing, but the relationship between ICD concerns......, psychological morbidity, and shocks has not been systematically investigated. We examined the relative importance of experienced shocks versus subjective concerns about the ICD as determinants of anxiety and depressive symptoms in ICD patients....

  3. Implantable cardioverter defibrillator implantation in children in The Netherlands

    NARCIS (Netherlands)

    Ten Harkel, ADJ; Blom, NA; Reimer, AG; Tukkie, R; Sreeram, N; Bink-Boelkens, MTE

    To evaluate the indications, underlying cardiac disorders, efficacy and complications involved with implantable cardioverter-defibrillators (ICDs) in paediatric patients in The Netherlands, the records of all patients aged 18 years or younger who underwent ICD placement were reviewed

  4. Implantable cardioverter defibrillator implantation in children in The Netherlands

    NARCIS (Netherlands)

    ten Harkel, A. Derk Jan; Blom, Nico A.; Reimer, Annette G.; Tukkie, Raymond; Sreeram, Narayanswami; Bink-Boelkens, Margreet T. E.

    2005-01-01

    To evaluate the indications, underlying cardiac disorders, efficacy and complications involved with implantable cardioverter-defibrillators (ICDs) in paediatric patients in The Netherlands, the records of all patients aged 18 years or younger who underwent ICD placement were reviewed

  5. Pacemakers and implantable cardioverter defibrillators - general and anesthetic considerations

    Directory of Open Access Journals (Sweden)

    Amy G. Rapsang

    2014-06-01

    Full Text Available A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia, special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary.

  6. Implantable cardioverter defibrillator specific rehabilitation improves health cost outcomes

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Zwisler, Ann-Dorthe; Koch, Mette Bjerrum

    2015-01-01

    OBJECTIVE: The Copenhagen Outpatient ProgrammE - implantable cardioverter defibrillator (COPE-ICD) trial included patients with implantable cardioverter defibrillators in a randomized controlled trial of rehabilitation. After 6-12 months significant differences were found in favour of the rehabil...... was -6,789 USD/-5,593 Euro in favour of rehabilitation. CONCLUSION: No long-term health outcome benefits were found for the rehabilitation programme. However, the rehabilitation programme resulted in a reduction in total attributable direct costs....... of the rehabilitation group for exercise capacity, general and mental health. The aim of this paper is to explore the long-term health effects and cost implications associated with the rehabilitation programme; more specifically, (i) to compare implantable cardioverter defibrillator therapy history and mortality...... between rehabilitation and usual care groups; (ii) to examine the difference between rehabilitation and usual care groups in terms of time to first admission; and (iii) to determine attributable direct costs. METHODS: Patients with first-time implantable cardioverter defibrillator implantation (n = 196...

  7. Daily remote monitoring of implantable cardioverter-defibrillators

    DEFF Research Database (Denmark)

    Hindricks, Gerhard; Varma, Niraj; Kacet, Salem

    2017-01-01

    Aims: Remote monitoring of implantable cardioverter-defibrillators may improve clinical outcome. A recent meta-analysis of three randomized controlled trials (TRUST, ECOST, IN-TIME) using a specific remote monitoring system with daily transmissions [Biotronik Home Monitoring (HM)] demonstrated...

  8. Pre-implantation implantable cardioverter defibrillator concerns and Type D personality increase the risk of mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Erdman, Ruud A M

    2010-01-01

    Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients.......Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients....

  9. Cardioverter-defibrillator implantation in myeloma-associated cardiac amyloidosis.

    Science.gov (United States)

    Campanile, Alfonso; Sozzi, Fabiola B; Canetta, Ciro; Danzi, Gian Battista

    2013-01-01

    A 62-year-old woman with multiple myeloma and light-chain amyloidosis with significant heart involvement developed an in-hospital cardiac arrest. After cardiopulmonary resuscitation, a stable sinus rhythm without any cerebral damage was restored, and the patient was admitted to the coronary care unit. A cardioverter-defibrillator was implanted, and it successfully intervened in two sustained ventricular tachycardia episodes and one ventricular fibrillation episode, which were recorded during hospitalization. After achieving discrete cardiac compensation, the patient was transferred to the emergency medicine department where she underwent chemotherapy for multiple myeloma. The patient died 40 days after admission from refractory heart failure. In the literature, there are studies that describe the use of cardioverter-defibrillator implantation in cardiac amyloidosis; however, at present, there is no evidence of a beneficial effect on survival with the use of this intervention. A high index of suspicion for amyloid heart disease and early diagnosis are critical to improving outcomes.

  10. Behavioral interventions in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Burg, Matthew M; Pedersen, Susanne S.

    2013-01-01

    The implantable cardioverter defibrillator (ICD) is the first-line treatment for primary and secondary prevention of sudden cardiac death. A subgroup of patients experience psychological distress postimplant, and no clear evidence base exists regarding how best to address patients' needs. The aim...... of this critical review is to provide an overview of behavioral interventions in ICD patients to date, and to delineate directions for future research using lessons learned from the ongoing RISTA and WEBCARE trials....

  11. Depressive symptoms in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Andersen, Christina M; Denollet, Johan

    2018-01-01

    OBJECTIVE: Patients with an implantable cardioverter defibrillator (ICD) and co-morbid depression are at greater risk of poor quality of life and premature death. We examined if treatment expectations predict depressive symptoms 12months post implant. METHODS: First-time implant patients from...... of 12-months depressive symptoms: Model 1: Negative treatment expectations (β=0.202; p=0.020) and baseline depression (β=0.376; pdepression (β=0.350; p....051). Model 3: Baseline depression (β=0.353; p

  12. Making post-mortem implantable cardioverter defibrillator explantation safe

    DEFF Research Database (Denmark)

    Räder, Sune B E W; Zeijlemaker, Volkert; Pehrson, Steen

    2009-01-01

    that the resting voltage over the operating person would not exceed 50 V. CONCLUSION: The use of intact medical gloves made of latex, neoprene, or plastic eliminates the potential electrical risk during explantation of an ICD. Two gloves on each hand offer sufficient protection. We will recommend the use......AIMS: The aim of this study is to investigate whether protection with rubber or plastic gloves during post-mortem explantation of an implantable cardioverter defibrillator (ICD) offers enough protection for the explanting operator during a worst-case scenario (i.e. ICD shock). METHODS AND RESULTS...

  13. Impact of carvedilol and metoprolol on inappropriate implantable cardioverter-defibrillator therapy

    DEFF Research Database (Denmark)

    Ruwald, Martin H; Abu-Zeitone, Abeer; Jons, Christian

    2013-01-01

    The goal of this study was to evaluate the effects of carvedilol and metoprolol on the endpoint of inappropriate implantable cardioverter-defibrillator therapy in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy) study....

  14. Psychological distress in patients with an implantable cardioverter defibrillator

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Shiga, MD

    2013-12-01

    Full Text Available Despite the effectiveness of an implantable cardioverter defibrillator (ICD, its implantation and concomitant therapies, including shocks, can induce psychological distress in patients. Depression has been observed in approximately 30% of ICD patients, and shocks may contribute to the persistence of depression. Anxiety is common, with reports of 24–87% of ICD patients experiencing symptoms of anxiety after implantation, and type D personality and ICD-related concerns may play important roles in the level of anxiety in ICD patients. However, the association between ICD shocks and anxiety is controversial. The prevalence of posttraumatic stress disorder (PTSD in ICD patients is approximately 20%, and type D personality, comorbidities, and frequent shocks may contribute to PTSD. It is also important to pay attention to the psychological distress in the partners of ICD patients.

  15. Correlation of geomagnetic activity with implantable cardioverter defibrillator shocks and antitachycardia pacing

    Czech Academy of Sciences Publication Activity Database

    Ebrille, E.; Konecny, T.; Konecny, D.; Špaček, R.; Jones, P.; Ambrož, Pavel; DeSimone, C.V.; Powel, B.D.; Hayes, D.L.; Friedman, P.A.; Asirvatham, S.J.

    2015-01-01

    Roč. 90, č. 2 (2015), s. 202-208 ISSN 0025-6196 Institutional support: RVO:67985815 Keywords : geomagnetic activity * implantable cardioverter defibrillator Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 5.920, year: 2015

  16. Driving safety among patients with automatic implantable cardioverter defibrillators.

    Science.gov (United States)

    Finch, N J; Leman, R B; Kratz, J M; Gillette, P C

    1993-10-06

    To determine the driving behavior of patients following the placement of automatic implantable cardioverter defibrillators (AICDs). Forty patients with AICDs (33 men, seven women; mean age, 62.7 years) responded to a questionnaire designed to ascertain driving behavior after hospital discharge. Despite medical advice never to drive again, 28 patients (70%) resumed driving, with the majority doing so by 8 months after AICD implantation. Of these, 11 (40%) identified themselves as the primary driver in their household. Fourteen (50%) drove daily. Two (7%) were driving and continued to drive during discharge of their AICDs. Twenty-five (91%) reported that they felt comfortable and safe while driving. A majority of patients with AICDs continue to drive after a proscription of this activity by health care workers.

  17. Management of Implantable Cardioverter Defibrillator Recipients: Care Beyond Guidelines.

    Science.gov (United States)

    Philippon, François; Sterns, Laurence D; Nery, Pablo B; Parkash, Ratika; Birnie, David; Rinne, Claus; Mondesert, Blandine; Exner, Derek; Bennett, Matthew

    2017-08-01

    This companion article is intended to address common clinical scenarios in patients with implantable defibrillators that were not addressed in the 2016 Canadian Cardiovascular Society/Canadian Heart Rhythm Society implantable cardioverter defibrillator guidelines including recommendations for device programming to improve detection, to minimize shocks (appropriate and inappropriate), and to minimize ventricular pacing. Important issues at the time of replacement such as device prescription, technical aspects (vascular access, extraction), and management of components on advisories are also discussed. Finally, common clinical scenarios such as management of patients with terminal illnesses, recurrent ventricular tachycardia, electrical storms, catheter ablation for ventricular tachycardia, and system infection management are considered. The management of these patients requires a team approach and comprehensive knowledge surrounding these common clinical scenarios. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  18. Azygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement

    Directory of Open Access Journals (Sweden)

    Naga VA Kommuri

    2010-01-01

    Full Text Available Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.

  19. Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators.

    Science.gov (United States)

    Alam, Mian Bilal; Munir, Muhammad Bilal; Rattan, Rohit; Flanigan, Susan; Adelstein, Evan; Jain, Sandeep; Saba, Samir

    2014-02-01

    Cardiac resynchronization therapy (CRT) implantable cardioverter defibrillators (ICDs) deliver high burden ventricular pacing to heart failure patients, which has a significant effect on battery longevity. The aim of this study was to investigate whether battery longevity is comparable for CRT-ICDs from different manufacturers in a contemporary cohort of patients. All the CRT-ICDs implanted at our institution from 1 January 2008 to 31 December 2010 were included in this analysis. Baseline demographic and clinical data were collected on all patients using the electronic medical record. Detailed device information was collected on all patients from scanned device printouts obtained during routine follow-up. The primary endpoint was device replacement for battery reaching the elective replacement indicator (ERI). A total of 646 patients (age 69 ± 13 years), implanted with CRT-ICDs (Boston Scientific 173, Medtronic 416, and St Jude Medical 57) were included in this analysis. During 2.7 ± 1.5 years follow-up, 113 (17%) devices had reached ERI (Boston scientific 4%, Medtronic 25%, and St Jude Medical 7%, P battery was significantly worse for Medtronic devices compared with devices from other manufacturers (94% for Boston scientific, 67% for Medtronic, and 92% for St Jude Medical, P battery longevity by manufacturer was independent of pacing burden, lead parameters, and burden of ICD therapy. There are significant discrepancies in CRT-ICD battery longevity by manufacturer. These data have important implications on clinical practice and patient outcomes.

  20. Attrition and Adherence in a Web-Based Distress Management Program for Implantable Cardioverter Defibrillator Patients (WEBCARE): Randomized Controlled Trial

    DEFF Research Database (Denmark)

    Habibovic, M.; Cuijpers, P.; Alings, M.

    2014-01-01

    Background: WEB-Based Distress Management Program for Implantable CARdioverter defibrillator Patients (WEBCARE) is a Web-based randomized controlled trial, designed to improve psychological well-being in patients with an implantable cardioverter defibrillator (ICD). As in other Web-based trials, ...

  1. Spinal cord stimulation for refractory angina in patients implanted with cardioverter defibrillators: five case reports

    DEFF Research Database (Denmark)

    Enggaard, Thomas P; Andersen, Claus; Scherer, Christian

    2010-01-01

    Patients implanted with a cardioverter defibrillator (ICD) who are suffering from refractory angina pectoris could benefit from spinal cord stimulation (SCS) due to the well-documented pain relieving effect. However, the combined treatment remains controversial. The aim of the study is to report...... successful long-term treatment with SCS in five patients implanted with cardioverter defibrillators. The combined treatments with ICD and thoracic epidural electrical stimulation were used in five patients with refractory angina pectoris. During the procedure of the implantation, testing with the maximal...... for refractory angina pectoris can be performed in patients implanted with cardioverter defibrillators without interference. However, individual testing during implantation or re-programming the devices is mandatory in order to assess optimal safety in each patient....

  2. Antitachycardia pacing programming in implantable cardioverter defibrillator: A systematic review.

    Science.gov (United States)

    De Maria, Elia; Giacopelli, Daniele; Borghi, Ambra; Modonesi, Letizia; Cappelli, Stefano

    2017-05-26

    Implantable cardioverter defibrillator (ICD) programming involves several parameters. In recent years antitachycardia pacing (ATP) has gained an increasing importance in the treatment of ventricular arrhythmias, whether slow or fast. It reduces the number of unnecessary and inappropriate shocks and improves both patient's quality of life and device longevity. There is no clear indication regarding the type of ATP to be used, except for the treatment of fast ventricular tachycardias (188 bpm-250 bpm) where it has been shown a greater efficacy and safety of burst compared to ramp; 8 impulses in each sequence of ATP appears to be the best programming option in this setting. Beyond ATP use, excellent clinical results were obtained with programming standardization following these principles: extended detection time in ventricular fibrillation (VF) zone; supraventricular discrimination criteria up to 200 bpm; first shock in VF zone at the maximum energy in order to reduce the risk of multiple shocks. The MADIT-RIT trial and some observational registries have also recently demonstrated that programming with a widespread use of ATP, higher cut-off rates or delayed intervention reduces the number of inappropriate and unnecessary therapies and improves the survival of patients during mid-term follow-up.

  3. Clinical performance of different DF-4 implantable cardioverter defibrillator leads.

    Science.gov (United States)

    Sarrazin, Jean-François; Philippon, François; Sellier, Romain; André, Philippe; O'Hara, Gilles; Molin, Franck; Nault, Isabelle; Blier, Louis; Champagne, Jean

    2018-06-01

    Implantable cardioverter-defibrillator (ICD) DF-4 connectors have been introduced to facilitate defibrillator lead connection and to reduce the size of device header. There are limited data regarding the overall performance of those leads and no comparison between different ICD DF-4 leads. This is a cohort study of consecutive patients implanted with ICD DF-4 lead system at one University Centre between October 2010 and February 2015. A historical control group of patients with ICD DF-1 lead implantation was used for comparison. The following ICD DF-4 leads were evaluated: St. Jude Medical Durata 7122Q (St. Jude Medical, St. Paul, MN, USA), Medtronic Sprint Quattro Secure 6935 M (Medtronic Inc., Minneapolis, MN, USA), Boston Scientific Endotak Reliance 4-Site 0293 (Boston Scientific, Marlborough, MA, USA), and Boston Scientific Reliance 4-Front 0693. This study evaluated the acute and mid-term performances of those leads as well as complications. A total of 812 patients (age 63 ± 12 years, 80% male, left ventricular ejection fraction 31 ± 12%) underwent implantation of an ICD DF-4 lead. Acute and follow-up R-wave sensing and threshold were excellent. Compared to implantation, intrinsic R waves were higher at follow-up for Boston Scientific and Medtronic leads, and pacing lead impedances were lower for all leads at first follow-up (P < 0.001). The number of lead dislodgement or failure was similar between all leads. The estimated lead survival rates at 3 years were 95.6% for Boston Scientific Endotak 4-Site, 97.1% for Boston Scientific 4-Front, 97.7% for Medtronic Sprint Quattro, and 97.5% for St. Jude Durata (P  =  0.553). All ICD DF-4 leads had excellent acute and mid-term electrical performances. Longer follow-up will be necessary to confirm their sustained performance. © 2018 Wiley Periodicals, Inc.

  4. Anxiety and risk of ventricular arrhythmias or mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Pedersen, Susanne S.; van den Broek, Krista C

    2013-01-01

    A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences anxiety after device implantation. The purpose of the present study was to evaluate whether anxiety is predictive of ventricular arrhythmias and all-cause mortality 1 year post ICD implantation....

  5. Intra-operative defibrillation testing and clinical shock efficacy in patients with implantable cardioverter-defibrillators

    DEFF Research Database (Denmark)

    Bänsch, Dietmar; Bonnemeier, Hendrik; Brandt, Johan

    2015-01-01

    AIMS: This trial was designed to test the hypothesis that shock efficacy during follow-up is not impaired in patients implanted without defibrillation (DF) testing during first implantable cardioverter-defibrillator (ICD) implantation. METHODS AND RESULTS: Between February 2011 and July 2013, 107...

  6. Monitoring device acceptance in implantable cardioverter defibrillator patients using the Florida Patient Acceptance Survey

    DEFF Research Database (Denmark)

    Versteeg, Henneke; Starrenburg, Annemieke; Denollet, Johan

    2012-01-01

    Patient device acceptance might be essential in identifying patients at risk for adverse patient-reported outcomes following implantation of an implantable cardioverter defibrillator (ICD). We examined the validity and reliability of the Florida Patient Acceptance Scale (FPAS) and identified corr...

  7. Dual chamber arrhythmia detection in the implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-10-01

    Dual chamber implantable cardioverter defibrillator (ICD) technology extended ICD therapy to more than termination of hemodynamically unstable ventricular tachyarrhythmias. It created the basis for dual chamber arrhythmia management in which dependable detection is important for treatment and prevention of both ventricular and atrial arrhythmias. Dual chamber detection algorithms were investigated in two Medtronic dual chamber ICDs: the 7250 Jewel AF (33 patients) and the 7271 Gem DR (31 patients). Both ICDs use the same PR Logic algorithm to interpret tachycardia as ventricular tachycardia (VT), supraventricular tachycardia (SVT), or dual (VT+ SVT). The accuracy of dual chamber detection was studied in 310 of 1,367 spontaneously occurring tachycardias in which rate criterion only was not sufficient for arrhythmia diagnosis. In 78 episodes there was a double tachycardia, in 223 episodes SVT was detected in the VT or ventricular fibrillation zone, and in 9 episodes arrhythmia was detected outside the boundaries of the PR Logic functioning. In 100% of double tachycardias the VT was correctly diagnosed and received priority treatment. SVT was seen in 59 (19%) episodes diagnosed as VT. The causes of inappropriate detection were (1) algorithm failure (inability to fulfill the PR

  8. Electromagnetic Interference in Patients with Implanted Cardioverter-Defibrillators and Implantable Loop Recorders

    Directory of Open Access Journals (Sweden)

    Marcos de Sousa

    2002-07-01

    Full Text Available Modern life exposes us all to an ever-increasing number of potential sources of electromagnetic interference (EMI and patients with Implantable rhythm devices (IRD like pacemakers, implantable cardioverter defibrillators or implantable loop recorders often ask about the use of microwave ovens, walking through airport metal detectors and the use of cellular phones. Electromagnetic interference occurs when electromagnetic waves emitted by one device impede the normal function of another electronic device. The potential for interaction between implanted pacing systems and cardioverter-defibrillators (electromagnetic interference, EMI has been recognized for years.1,2,3,4. It has been shown that EMI can produce clinically significant effects on patients with implanted pacemakers and ICDs. For these reasons the following text discusses the influence of several EMI generating devices on IRD .

  9. Experiences of patients with implantable cardioverter defibrillator in Turkey: A qualitative study

    Directory of Open Access Journals (Sweden)

    Özgür Aslan

    2012-01-01

    Full Text Available Background. There has been an increase in the number of patients with implantable cardioverter defibrillator (ICD. It isimportant to understand ICD patients’ experiences with it.Aim. The aim of this study was to describe experiences of patients with implantable cardioverter defibrillator (ICD.Methodology. A qualitative approach was used. Focus group interviews were used to obtain data from 19 patients whowere implanted cardioverter defibrillator at two centers in Izmir, Turkey. The patients were assigned into four groups. Thedata was analyzed using qualitative content analysis.Results. The analysis revealed six main themes: activities of daily living, social life, familial relationships, emotionalchanges, implantable cardioverter defibrillator shocks and experiences with receiving information and counselling fromhealth care providers.Conclusions. It can be concluded that patients with ICD experience physical and psychological problems and are not offeredthe education they need. To reduce the fears of the patients and their families and to prepare them for possible life stylechanges, comprehensive training programs that start in the pre-implantation period and continue into the post-implantationperiod should be organized.

  10. Gender disparities in anxiety and quality of life in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; van den Broek, Krista C; Theuns, Dominic A M J

    2011-01-01

    A paucity of studies in implantable cardioverter-defibrillator (ICD) patients has examined gender disparities in patient-reported outcomes, such as anxiety and quality of life (QoL). We investigated (i) gender disparities in anxiety and QoL and (ii) the magnitude of the effect of gender vs. New...

  11. E-Health to Manage Distress in Patients With an Implantable Cardioverter-Defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Denollet, Johan; Cuijpers, Pim

    2014-01-01

    UNLABELLED: The Web-based distress management program for patients with an implantable cardioverter-defibrillator (ICD; WEBCARE) was developed to mitigate distress and enhance health-related quality of life in ICD patients. This study investigated the treatment effectiveness at 3-month follow-up ...

  12. Implantable cardioverter defibrillator therapy for prevention of sudden cardiac death in children in the Netherlands

    NARCIS (Netherlands)

    Heersche, Jogien H. M.; Blom, Nico A.; van de Heuvel, Freek; Blank, Christiaan; Reimer, Annette G.; Clur, Sally-Ann; Witsenburg, Maarten; ten Harkel, A. Derk Jan

    2010-01-01

    INTRODUCTION: Implantable cardioverter defibrillator (ICD) therapy is increasingly used in children. The purpose of this multicenter study is to evaluate mid-term clinical outcome and to identify predictors for device discharge in pediatric ICD recipients. METHODS AND RESULTS: From 1995 to 2006, 45

  13. SUDDEN CARDIAC DEATH AND THE USE OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS IN PEDIATRIC-PATIENTS

    NARCIS (Netherlands)

    SILKA, MJ; KRON, J; DUNNIGAN, A; DICK, M; BINKBOELKENS, M; ERICKSON, CC; JEDEIKIN, R; WETZEL, GT; VANHARE, GF; CAMPBELL, R; WALSH, E; SAUL, JP; SCHAFFER, MS; KARPAWICH, P; VOGEL, RL; BENSON, DW; DEAL, B; SCAGLIOTTI, D; STERBA, R; HORDOF, AJ; KRONGRAD, E; KANTER, RJ; EPSTEIN, M; COHEN, M; BEDER, S; HAMILTON, R; FOURNIER, A; HUBBARD, J; CHRISTIANSEN, JL; JENNINGS, J; VILLAFANE, J; PORTER, CBJ; CASE, C; GILLETTE, PC; BELAND, M; KUGLER, JD; OCONNOR, BK; ALLENDER, H; HERNDON, SP; SMITH, RT; BURTON, D; KURER, CC; BYRUM, C; GUAM, WE; FRIEDMAN, R; PERRY, JC; SCOTT, W; MEHTA, AV; PICKHOFF, AS; FISH, F; YEAGER, S; KAWABORI, [No Value; TRIPPLE, M; ROSENFELD, LE

    Background. During the past decade. the implantable cardioverter-defibrillator (ICD) has emerged as the primary therapeutic option for survivors of sudden cardiac death (SCD). Investigation of the clinical efficacy of these devices has primarily assessed outcome in adults with coronary artery

  14. Implantable Cardioverter Defibrillator Therapy for Prevention of Sudden Cardiac Death in Children in The Netherlands

    NARCIS (Netherlands)

    Heersche, Jogien H. M.; Blom, Nico A.; Van De Heuvel, Freek; Blank, Christiaan; Reimer, Annette G.; Clur, Sally-Ann; Witsenburg, Maarten; Ten Harkel, A. Derk Jan

    Introduction: Implantable cardioverter defibrillator (ICD) therapy is increasingly used in children. The purpose of this multicenter study is to evaluate mid-term clinical outcome and to identify predictors for device discharge in pediatric ICD recipients. Methods and Results: From 1995 to 2006, 45

  15. Undertreatment of anxiety and depression in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J

    2012-01-01

    Twenty-five to 33% of patients with an implantable cardioverter-defibrillator (ICD) experience anxiety and depression, but it is not known whether their symptoms are adequately treated. We investigated (a) whether patients with clinically relevant symptoms of distress received appropriate treatme......, and (b) whether patients not treated for their emotional distress reported poorer health status using a prospective study design....

  16. Ventricular Tachyarrhythmias and Mortality in Patients With an Implantable Cardioverter Defibrillator

    DEFF Research Database (Denmark)

    Mastenbroek, Mirjam H; Versteeg, Henneke; Jordaens, Luc

    2014-01-01

    Objective We examined whether depression is independently associated with implantable cardioverter defibrillator (ICD) therapy for ventricular tachyarrhythmias and mortality. Methods A cohort of 430 consecutive patients with a first-time ICD (79% men; mean [standard deviation] age = 57.8 [12.1] y...

  17. Inappropriate shock delivery by implantable cardioverter defibrillator due to electrical interference with washing machine.

    Science.gov (United States)

    Chongtham, Dhanaraj Singh; Bahl, Ajay; Kumar, Rohit Manoj; Talwar, K K

    2007-05-31

    We report a patient with hypertrophic cardiomyopathy who received an inappropriate implantable cardioverter defibrillator shock due to electrical interference from a washing machine. This electrical interference was detected as an episode of ventricular fibrillation with delivery of shock without warning symptoms.

  18. "Real life" longevity of implantable cardioverter-defibrillator devices.

    Science.gov (United States)

    Manolis, Antonis S; Maounis, Themistoklis; Koulouris, Spyridon; Vassilikos, Vassilios

    2017-09-01

    Manufacturers of implantable cardioverter-defibrillators (ICDs) promise a 5- to 9-year projected longevity; however, real-life data indicate otherwise. The aim of the present study was to assess ICD longevity among 685 consecutive patients over the last 20 years. Real-life longevity of ICDs may differ from that stated by the manufacturers. The study included 601 men and 84 women (mean age, 63.1 ± 13.3 years). The underlying disease was coronary (n = 396) or valvular (n = 15) disease, cardiomyopathy (n = 220), or electrical disease (n = 54). The mean ejection fraction was 35%. Devices were implanted for secondary (n = 562) or primary (n = 123) prevention. Single- (n = 292) or dual-chamber (n = 269) or cardiac resynchronization therapy (CRT) devices (n = 124) were implanted in the abdomen (n = 17) or chest (n = 668). Over 20 years, ICD pulse generator replacements were performed in 238 patients (209 men; age 63.7 ± 13.9 years; ejection fraction, 37.7% ± 14.0%) who had an ICD for secondary (n = 210) or primary (n = 28) prevention. The mean ICD longevity was 58.3 ± 18.7 months. In 20 (8.4%) patients, devices exhibited premature battery depletion within 36 months. Most (94%) patients had none, minor, or modest use of ICD therapy. Longevity was longest for single-chamber devices and shortest for CRT devices. Latest-generation devices replaced over the second decade lasted longer compared with devices replaced during the first decade. When analyzed by manufacturer, Medtronic devices appeared to have longer longevity by 13 to 18 months. ICDs continue to have limited longevity of 4.9 ± 1.6 years, and 8% demonstrate premature battery depletion by 3 years. CRT devices have the shortest longevity (mean, 3.8 years) by 13 to 17 months, compared with other ICD devices. These findings have important implications, particularly in view of the high expense involved with this type of electrical

  19. “Atrial torsades de pointes” Induced by Low-Energy Shock From Implantable-Cardioverter Defibrillator

    Directory of Open Access Journals (Sweden)

    Ilknur Can, MD

    2013-09-01

    Full Text Available A 58 year-old-patient developed an episode of polymorphic atrial tachycardia which looked like "atrial torsades de pointes" after a 5J shock from implantable cardioverter defibrillator.

  20. Venous Obstruction Following Pacemaker or Implantable Cardioverter-Defibrillator Implantation, Mini Review

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Akbarzadeh

    2016-08-01

    Full Text Available Venous obstruction is relatively frequent following permanent pacemaker or implantable cardioverter-defibrillator (ICD implantation. However, most of them are asymptomatic. Although the exact risk factor for this complication is not known, number of leads, heart failure and infection may prone the patient to this complication. The goal standard for detection of vein stenosis is venography; however, ultrasound sonography has an acceptable accuracy. Anticoagulant therapy may be considered for symptomatic patients. For device upgrading, non-functional leads removal, venoplasty and rarely surgical treatment may be indicated.

  1. Beam Profile Disturbances from Implantable Pacemakers or Implantable Cardioverter-Defibrillator Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Gossman, Michael S., E-mail: mgossman@tsrcc.com [Tri-State Regional Cancer Center, Medical Physics Section, Ashland, KY (United States); Comprehensive Heart and Vascular Associates, Heart and Vascular Center, Ashland, KY (United States); Medtronic, Inc., External Research Program, Mounds View, MN (United States); Nagra, Bipinpreet; Graves-Calhoun, Alison; Wilkinson, Jeffrey [Tri-State Regional Cancer Center, Medical Physics Section, Ashland, KY (United States); Comprehensive Heart and Vascular Associates, Heart and Vascular Center, Ashland, KY (United States); Medtronic, Inc., External Research Program, Mounds View, MN (United States)

    2011-01-01

    The medical community is advocating for progressive improvement in the design of implantable cardioverter-defibrillators and implantable pacemakers to accommodate elevations in dose limitation criteria. With advancement already made for magnetic resonance imaging compatibility in some, a greater need is present to inform the radiation oncologist and medical physicist regarding treatment planning beam profile changes when such devices are in the field of a therapeutic radiation beam. Treatment plan modeling was conducted to simulate effects induced by Medtronic, Inc.-manufactured devices on therapeutic radiation beams. As a continuation of grant-supported research, we show that radial and transverse open beam profiles of a medical accelerator were altered when compared with profiles resulting when implantable pacemakers and cardioverter-defibrillators are placed directly in the beam. Results are markedly different between the 2 devices in the axial plane and the sagittal planes. Vast differences are also presented for the therapeutic beams at 6-MV and 18-MV x-ray energies. Maximum changes in percentage depth dose are observed for the implantable cardioverter-defibrillator as 9.3% at 6 MV and 10.1% at 18 MV, with worst distance to agreement of isodose lines at 2.3 cm and 1.3 cm, respectively. For the implantable pacemaker, the maximum changes in percentage depth dose were observed as 10.7% at 6 MV and 6.9% at 18 MV, with worst distance to agreement of isodose lines at 2.5 cm and 1.9 cm, respectively. No differences were discernible for the defibrillation leads and the pacing lead.

  2. Spiritual well-being may buffer psychological distress in patients with implantable cardioverter defibrillators (ICD)

    OpenAIRE

    Salmoirago-Blotcher, Elena; Crawford, Sybil; Tran, Chau; Goldberg, Robert; Rosenthal, Lawrence; Ockene, Ira

    2012-01-01

    Psychological distress is common in patients with implantable cardioverter defibrillators (ICDs) and has been associated with a worse prognosis. The authors examined whether spiritual wellbeing is associated with reduced psychological distress in patients with ICDs. The Functional Assessment of Chronic Illness Therapy-Spiritual Wellbeing (FACIT-SWB) questionnare and the Hospital Anxiety and Depression Scale (HADS) were used to measure spiritual wellbeing and overall psychological distress. Mu...

  3. Symptomatic heart failure is the most important clinical correlate of impaired quality of life, anxiety, and depression in implantable cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Johansen, Jens B; Pedersen, Susanne S.; Spindler, Helle

    2008-01-01

    To identify correlates of impaired quality of life (QOL), anxiety, and depression in patients with an implantable cardioverter-defibrillator (ICD).......To identify correlates of impaired quality of life (QOL), anxiety, and depression in patients with an implantable cardioverter-defibrillator (ICD)....

  4. Intensity of primary emotions in patients after implantation of an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Stoier, Louise; Pedersen, Preben Ulrich; Berg, Selina Kikkenborg

    2013-01-01

    Background: Experienced emotions can affect the outcome of, and adherence to a cardiac rehabilitation program, and patients coping with an illness. With more awareness of the expressed emotions, health professionals might be better able to understand the reactions of patients and to improve...... the support needed for coping. Living with an Implantable Cardi- overter Defibrillator can lead to anxiety and depression. Focus on the intensity of the primary emotions might be a potential to prevent development of these psychological states. Objectives: The aim of this paper are 1) to describe...... the intensity of primary emotions in patients after implantation of an Implantable Cardioverter Defibrillator and 2) to compare them with both the intensity of primary emotions in patients with a recent Myocardial Infarction and with a healthy population. Method: The intensity of primary emotions in patients...

  5. The use of guideline recommended beta-blocker therapy in primary prevention implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Ruwald, Anne Christine; Gislason, Gunnar Hilmar; Vinther, Michael

    2017-01-01

    Aims: We aimed to examine the use of guideline recommended beta-blocker therapy prior to and after primary prevention implantable cardioverter defibrillator (ICD) implantation in a 'real-life' setting. Methods and results: From the Danish Pacemaker and ICD Registry we identified all 1st-time prim......Aims: We aimed to examine the use of guideline recommended beta-blocker therapy prior to and after primary prevention implantable cardioverter defibrillator (ICD) implantation in a 'real-life' setting. Methods and results: From the Danish Pacemaker and ICD Registry we identified all 1st......-time primary prevention ICD and cardiac resynchronization therapy defibrillator (CRT-D) implantations in Denmark from 2007-12 (n = 2935). Use of beta-blocker, type and dose was acquired through the Danish Prescription Registry. According to guideline recommendations, we defined target daily doses as ≥50 mg...... carvedilol and ≥200 mg metoprolol. Prior to implantation 2427 of 2935 (83%) patients received beta-blocker therapy, with 2166 patients (89%) having initiated treatment 3 months or more prior to implantation. The majority of patients was prescribed carvedilol (52%) or metoprolol (41%). Patients on carvedilol...

  6. The oral cavity is not a primary source for implantable pacemaker or cardioverter defibrillator infections

    Science.gov (United States)

    2013-01-01

    Background To test the hypothesis that the oral cavity is a potential source for implantable pacemaker and cardioverter defibrillators infections, the bacterial diversity on explanted rhythm heart management devices was investigated and compared to the oral microbiome. Methods A metagenomic approach was used to analyze the bacterial diversity on the surfaces of non-infected and infected pacemakers. The DNA from surfaces swaps of 24 non-infected and 23 infected pacemaker were isolated and subjected to bacterial-specific DNA amplification, single strand conformation polymorphism- (SSCP) and sequencing analysis. Species-specific primer sets were used to analyze for any correlation between bacterial diversity on pacemakers and in the oral cavity. Results DNA of bacterial origin was detected in 21 cases on infected pacemakers and assigned to the bacterial phylotypes Staphylococcus epidermidis, Propionibacterium acnes, Staphylococcus aureus, Staphylococcus schleiferi and Stapyhlococcus. In 17 cases bacterial DNA was found on pacemakers with no clinical signs of infections. On the basis of the obtained sequence data, the phylotypes Propionibacterium acnes, Staphylococcus and an uncultured bacterium were identified. Propionibacterium acnes and Staphylococcus epidermidis were the only bacteria detected in pacemeaker (n = 25) and oral samples (n = 11). Conclusions The frequency of the coincidental detection of bacteria on infected devices and in the oral cavity is low and the detected bacteria are highly abundant colonizers of non-oral human niches. The transmission of oral bacteria to the lead or device of implantable pacemaker or cardioverter defibrillators is unlikely relevant for the pathogenesis of pacemaker or cardioverter defibrillators infections. PMID:23575037

  7. Shock and patient preimplantation type D personality are associated with poor health status in patients with implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Tekle, Fetene B; Hoogwegt, Madelein T

    2012-01-01

    Implantable cardioverter-defibrillator (ICD) shock is a critical event to patients associated with well-being after implantation, although other factors may play an equally important role. We compared the association of shock and the patient's preimplantation personality with health status, using...

  8. Dutch outcome in implantable cardioverter-defibrillator therapy (DO-IT) : Registry design and baseline characteristics of a prospective observational cohort study to predict appropriate indication for implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    Van Barreveld, M. (M.); M.G.W. Dijkgraaf (Marcel); Hulleman, M. (M.); L. Boersma (Lucas); P.P.H.M. Delnoy (Peter Paul); M. Meine (Mathias); Tuinenburg, A.E. (A. E.); D.A.M.J. Theuns (Dominic); P. van der Voort (Pepijn); G-J.P. Kimman (Geert-Jan); E. Buskens (Erik); Tijssen, J.P.G. (J. P.G.); Bruinsma, N. (N.); Verstraelen, T.E. (T. E.); A.H. Zwinderman (Ailko); Van Dessel, P.H.F.M. (P. H.F.M.); A.A.M. Wilde (Arthur)

    2017-01-01

    textabstractBackground Implantable cardioverter-defibrillators (ICDs) are widely used for the prevention of sudden cardiac death. At present, both clinical benefit and cost-effectiveness of ICD therapy in primary prevention patients are topics of discussion, as only a minority of these patients will

  9. A review of economic evaluation models for cardiac resynchronization therapy with implantable cardioverter defibrillators in patients with heart failure

    NARCIS (Netherlands)

    Tomini, F.; van Asselt, A. D.

    OBJECTIVES: Cardiac resynchronization therapy with biventricular pacemaker (CRT-P) is considered an effective treatment for heart failure (HF). Adding implantable cardioverter defibrillators (CRT-D) may further reduce the risk of sudden cardiac death (SCD). However, economic evaluations have shown

  10. A review of economic evaluation models for cardiac resynchronization therapy with implantable cardioverter defibrillators in patients with heart failure

    NARCIS (Netherlands)

    Tomini, F.; van Asselt, A. D.

    2012-01-01

    OBJECTIVES: Cardiac resynchronization therapy with biventricular pacemaker (CRT-P) is considered an effective treatment for heart failure (HF). Adding implantable cardioverter defibrillators (CRT-D) may further reduce the risk of sudden cardiac death (SCD). However, economic evaluations have shown

  11. Patient-reported outcomes in Danish implantable cardioverter defibrillator patients with a Sprint Fidelis lead advisory notification

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Versteeg, Henneke; Nielsen, Jens Cosedis

    2011-01-01

    Few studies have investigated the association between implantable cardioverter defibrillators (ICDs) and lead advisory notifications and patient-reported outcomes (PROs). We examined (i) whether the mode used to inform patients about a device advisory is associated with PROs, and (ii) whether...... patients with a lead subject to a device advisory report poorer PROs than non-advisory controls....

  12. Emotions and health: findings from a randomized clinical trial on psychoeducational nursing to patients with implantable cardioverter defibrillator.

    Science.gov (United States)

    Kikkenborg Berg, Selina; Støier, Louise; Moons, Philip; Zwisler, Ann-Dorthe; Winkel, Per; Ulrich Pedersen, Preben

    2015-01-01

    Serious illness will inevitably lead to a fundamental emotional reaction. Traditionally, in interventional treatment or rehabilitation trials, the psychological status of patients with implantable cardioverter defibrillators has been evaluated with anxiety and depression as outcome measures. In caring for these patients, the aim of nursing is to help patients manage life with complex heart disease. The early detection and management of negative emotional response might prevent the development of pathological conditions such as depression. The aims of this study were to (a) describe the trajectory of primary emotions over time in patients with implantable cardioverter defibrillators and (b) examine the potential effects of psychoeducational nursing on primary emotions. During the inclusion period (October 2007 to November 2009), 196 patients with implantable cardioverter defibrillator were randomized (1:1) to rehabilitation versus usual care. Rehabilitation consisted of a psychoeducational nursing component and an exercise training component. This article concerns phase 1, psychoeducational nursing, guided by a theory of nursing, Rosemary Rizzo Parses Human Becoming Practice Methodologies. The outcome measure is the Emotions and Health Scale. The scale consists of 8 primary emotions: joy, agreeableness, surprise, fear, sadness, disgust, anger, and anticipation. Mean (SD) age was 58 (13) years, and 79% of the participants were men. Significant improvements were found in primary emotional responses over time (P .05). Primary emotions are affected after implantable cardioverter defibrillator implantation. Improvements over time were found. However, it was not possible to detect any effect of a short-term psychoeducational nursing intervention. Evaluating the primary emotions might be a good way for nurses to monitor patients' psychological outcomes because the instrument is sensitive to changes over a short period. Further development of early psychoeducational nursing

  13. The Subcutaneous Implantable Cardioverter-Defibrillator: A Practical Review and Real-World Use and Application

    Directory of Open Access Journals (Sweden)

    Mark E. Panna Jr, MD, FACC, FHRS

    2016-02-01

    Full Text Available The subcutaneous implantable cardioverter-defibrillator (ICD is a novel technology using a subcutaneous (extrathoracic system for treatment of potential lethal ventricular arrhythmias. It avoids many of the risks of transvenous ICD implantation. It may be considered in patients having an ICD indication who do not have a pacing and/or cardiac resynchronization therapy indication, and who are unlikely to benefit from antitachycardia pacing therapy. We review patient selection, system components, the implantation technique, and screening considerations for subcutaneous ICD implantation. Its uses in specific patient populations, including children, patients with congenital heart disease, hypertrophic cardiomyopathy, or end-stage renal disease, and patients with preexisting pacemakers, are highlighted. Areas of future investigation are reviewed, including potential use with leadless pacing and magnetic resonance imaging.

  14. Trajectories of Patient-Reported Health Status in Patients With an Implantable Cardioverter Defibrillator

    DEFF Research Database (Denmark)

    Mastenbroek, Mirjam H; Denollet, Johan; Versteeg, Henneke

    2015-01-01

    , no use of ACE inhibitors, psychotropic medication, negative affectivity, and type D personality were identified as independent determinants of poorer mental health status. In conclusion, the population with an ICD seems to be heterogeneous in terms of patient-reported physical and mental health status......To date, no study has assessed the course of patient-reported health status in patients with an implantable cardioverter defibrillator (ICD). Studying health status trajectories and their baseline determinants would permit the identification of patients at risk for poor health outcomes after ICD...... implantation. A combined cohort of 1,222 patients with an ICD (79% men; age = 61.4 [11.2] years) completed the 12-Item Short-Form Health Survey at baseline and 2 to 3 months and 12 to 14 months after implantation. Latent class analyses were used to identify trajectories and predictors of health status over...

  15. Device orientation of a leadless pacemaker and subcutaneous implantable cardioverter-defibrillator in canine and human subjects and the effect on intrabody communication

    NARCIS (Netherlands)

    Quast, Anne-Floor B. E.; Tjong, Fleur V. Y.; Koop, Brendan E.; Wilde, Arthur A. M.; Knops, Reinoud E.; Burke, Martin C.

    2018-01-01

    The development of communicating modular cardiac rhythm management systems relies on effective intrabody communication between a subcutaneous implantable cardioverter-defibrillator (S-ICD) and a leadless pacemaker (LP), using conducted communication. Communication success is affected by the LP and

  16. Type D personality is associated with increased anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator and their partners

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van Domburg, Ron T; Theuns, Dominic A M J

    2014-01-01

    We investigated the prevalence of anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator (ICD) and their partners, and the role of personality factors and social support as determinants of distress....

  17. Relation of statin therapy to psychological functioning in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Theuns, Dominic A M J; Kupper, Nina

    2013-01-01

    Statin therapy is an important secondary prevention measure in cardiovascular disease. However, the side effects associated with statin use could potentially affect patients' quality of life. Little is known about the influence of statin therapy on the well-being and health status of cardiac...... patients, in general, and patients with an implantable cardioverter defibrillator (ICD), in particular. We investigated the association between statin therapy and symptoms of anxiety and depression and patients' health status during the 12 months after implantation, reckoning with statin type and dosage...... of statin type, dosage, and other potential confounders. The associations between statin therapy and depression (p = 0.06) and statin therapy and physical functioning (p = 0.05) were borderline significant, and no association was found with anxiety (p >0.05). In conclusion, statin therapy was associated...

  18. Electroconvulsive therapy in patients with cardiac pacemakers and implantable cardioverter defibrillators.

    Science.gov (United States)

    Dolenc, Tamara J; Barnes, Roxann D; Hayes, David L; Rasmussen, Keith G

    2004-09-01

    Electroconvulsive therapy (ECT) is used to treat major depressive illness, especially in elderly and medically frail patients. Not uncommonly, these patients have cardiac pacemakers or implantable cardioverter defibrillators (ICDs). Only a few case reports in the literature describe the use of ECT in such patients. Herein we review our ECT experience treating 26 pacemaker patients and 3 ICD patients. All patients obtained significant antidepressant benefits with ETC. Only one serious cardiac event occurred, a case of supraventricular tachycardia (SVT) requiring a stay on the cardiac intensive care unit. The SVT resolved and the patient went on to receive further uncomplicated ECT treatments. We conclude from this experience that with proper pre-ECT cardiac and pacemaker/defibrillator assessment, ECT can be safely and effectively administered to patients with an implanted cardiac device.

  19. Tricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation.

    Science.gov (United States)

    Chang, James D; Manning, Warren J; Ebrille, Elisa; Zimetbaum, Peter J

    2017-05-09

    The potential for cardiac implantable electronic device leads to interfere with tricuspid valve (TV) function has gained increasing recognition as having hemodynamic and clinical consequences associated with incremental morbidity and death. The diagnosis and treatment of lead-related (as distinct from functional) tricuspid regurgitation pose unique challenges. Because of pitfalls in routine diagnostic imaging, a high level of clinical suspicion must be maintained to avoid overlooking the possibility that worsening heart failure is a consequence of mechanical interference with TV leaflet mobility or coaptation and is amenable to lead extraction or valve repair or replacement. The future of cardiac implantable electronic devices includes pacing and perhaps defibrillation without a lead traversing the TV. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. [Full dental rehabilitation of a patient with implantable cardioverter defibrillator].

    Science.gov (United States)

    Imre, Ildikó; Tóth, Zsuzsanna

    2012-06-01

    During dental rehabilitation of a patient with ICD, an upper telescope retained overdenture with acrylic baseplate and lower cantilever bridges were constructed. In the consultation following the anamnesis and the clinical examination, the cardiologist did not believe antibiotic profilaxis to be necessary, adding that it is advisable to avoid the use of ultrasonic depurator and electrocauter. Nowadays after saving the life the improving of patient's better quality of life is an important aspect. The risk of ICD-implantation is minimal however, not negligible, the patient can pursue a way of life free of limitation. According to the latest trends, the number of ICD-implantations will increase exponentially in the near future, due to the aging of the population, the simplification and safeness of implantation and the increase of patients who can be treated with the device. In case of arritmia or putative dysfunction, the latest ICD-s are able to send emergency alert to the arritmia centre with the help of an outer transmitter. Probably the system will completely change the follow-up of patients with ICD within the next few years, clinical researches of its efficiency are going on at present.

  1. "Pseudo" Faraday cage: a solution for telemetry link interaction between a left ventricular assist device and an implantable cardioverter defibrillator.

    Science.gov (United States)

    Jacob, Sony; Cherian, Prasad K; Ghumman, Waqas S; Das, Mithilesh K

    2010-09-01

    Patients implanted with left ventricular assist devices (LVAD) may have implantable cardioverter defibrillators (ICD) implanted for sudden cardiac death prevention. This opens the possibility of device-device communication interactions and thus interferences. We present a case of such interaction that led to ICD communication failure following the activation of an LVAD. In this paper, we describe a practical solution to circumvent the communication interference and review the communication links of ICDs and possible mechanisms of ICD-LVAD interactions.

  2. Web-Based Distress Management for Implantable Cardioverter Defibrillator Patients

    DEFF Research Database (Denmark)

    Habibović, Mirela; Denollet, Johan; Cuijpers, Pim

    2017-01-01

    distress post-ICD implantation. The WEB-based distress management program for ICD patients (WEBCARE) was developed to mitigate anxiety and depression and enhance health-related quality of life in ICD patients. This study investigates the 6- and 12-months outcomes. METHOD: A total of 289 consecutive ICD...... care as usual. RESULTS: Current findings show no significant difference on anxiety, depression or quality of life between the WEBCARE and Usual Care group at 6- and 12-months postimplantation. CONCLUSIONS: In this clinical trial of a Web-based behavioral intervention for ICD patients, the Web...

  3. Phantom shocks in patients with implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Moons, Philip; Zwisler, Ann-Dorthe

    2013-01-01

    of phantom shocks.METHODS AND RESULTS: The design was secondary explorative analyses of data from a randomized controlled trial. One hundred and ninety-six patients with first-time ICD implantation (79% male, mean age 58 years) were randomized (1 : 1) to either combined rehabilitation or a control group...... questions regarding the experience of phantom shocks, date, time, and place. Twelve patients (9.4%) experienced a phantom shock, 7 in the intervention group and 5 in the control group (NS). Neither age, sex, quality of life nor perceived health at baseline was significantly related to the probability...

  4. Electrical storm in patients with implantable cardioverter-defibrillators: can it be forecast?

    Science.gov (United States)

    Emkanjoo, Zahra; Alihasani, Narges; Alizadeh, Abolfath; Tayyebi, Mohammad; Bonakdar, Hamid; Barakpour, Hamid; Sadr-Ameli, Mohammad Ali

    2009-01-01

    The aim of this retrospective study was to determine the prevalence and predictors of electrical storm in 227 patients who had received implantable cardioverter-defibrillators (ICDs) and had been monitored for 31.7 +/- 15.6 months. Of these, 174 (77%) were men. The mean age was 55.8 +/- 15.5 years (range, 20-85 yr), and the mean left ventricular ejection fraction (LVEF) was 0.30 +/- 0.14. One hundred forty-six of the patients (64%) had underlying coronary artery disease. Cardioverter-defibrillators were implanted for secondary (80%) and primary (20%) prevention. Of the 227 patients, 117 (52%) experienced events that required ICD therapy. Thirty patients (mean age, 57.26 +/- 14.3 yr) had > or = 3 episodes requiring ICD therapy in a 24-hour period and were considered to have electrical storm. The mean number of events was 12.75 +/- 15 per patient. Arrhythmia-clustering occurred an average of 6.1 +/- 6.7 months after ICD implantation. Clinical variables with the most significant association with electrical storm were low LVEF (P = 0.04; hazard ratio of 0.261, and 95% confidence interval of 0.08-0.86) and higher use of class IA antiarrhythmic drugs (P = 0.018, hazard ratio of 3.84, and 95% confidence interval of 1.47-10.05). Amiodarone treatment and use of beta-blockers were not significant predictors when subjected to multivariate analysis. We conclude that electrical storm is most likely to occur in patients with lower LVEF and that the use of Class IA antiarrhythmic drugs is a risk factor.

  5. Interactions between pacing and arrhythmia detection algorithms in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2001-09-01

    Dual chamber implantable cardioverter defibrillator (ICD) combines the possibility to detect and treat ventricular and atrial arrhythmias with the possibility of modern heart stimulation techniques. Advanced pacing algorithms together with extended arrhythmia detection capabilities can give rise to new types of device-device interactions. Some of the possible interactions are illustrated by four cases documented in four models of dual chamber ICDs. Functioning of new features in dual chamber devices is influenced by the fact that the pacemaker is not a separate device but a part of the ICD system and that both are being used in a patient with arrhythmia. Programming measures are suggested to optimize use of new pacing algorithms while maintaining correct arrhythmia detection.

  6. Attitudes towards implantable cardioverter-defibrillator therapy: a national survey in Danish health-care professionals

    DEFF Research Database (Denmark)

    Johansen, Jens B; Mortensen, Peter T; Videbæk, Regitze

    2011-01-01

    Aims The aim of this study was to examine health-care professionals attitudes towards implantable cardioverter-defibrillator (ICD) therapy and issues discussed with patients. Methods and results Survey of 209 health-care professionals providing specialized treatment and care of ICD patients......-physicians. Physicians were less likely to believe that their personal attitude towards ICD treatment has no influence on how they deal professionally with patients (27.8 vs. 43.6%; P = 0.04). Physicians and non-physicians were equally positive towards ICD therapy as primary prophylaxis in ischaemic cardiomyopathy (87...... discussing ICD treatment with candidate patients. At the same time, physicians are more aware that their attitude towards ICD treatment may influence how they deal professionally with patients compared with non-physicians....

  7. Illness perceptions in patients with heart failure and an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Timmermans, I.; Versteeg, H.; Meine, Mathias M

    2017-01-01

    Background Patients' illness perceptions are associated with psychological wellbeing and can be measured with the Brief Illness Perception Questionnaire (B-IPQ). However, little is known about illness perceptions in patients with heart failure. We examined the dimensional structure, validity...... and clinical and psychological correlates of the B-IPQ in Dutch, French and German patients with heart failure and an implantable cardioverter defibrillator (ICD). Method European heart failure patients (n=585) participating in the REMOTE-CIED study completed a set of questionnaires 1–2weeks post ICD.......69, with the ‘Consequences’ subscale being more internally consistent (α=0.80). Both the B-IPQ and its ‘Consequences’ subscale were significantly correlated with a number of psychological characteristics, but not with clinical characteristics. Multivariable logistic regression analysis indicated that threatening illness...

  8. Patients' perspective on deactivation of the implantable cardioverter-defibrillator near the end of life

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Chaitsing, Rismy; Szili-Torok, Tamas

    2013-01-01

    (67%) completed the survey. Most patients (68%) were aware that it is possible to turn the ICD off, and 95% believed it is important to inform patients about the possibility. Of the patients completing the survey, 84% indicated a choice for or against deactivation. Psychological morbidity......Recent guidelines have emphasized the importance of discussing the issue of deactivation near the end of life with patients with an implantable cardioverter-defibrillator (ICD). Few studies have examined the patient perspective and patients' wishes. We examined patients' knowledge and wishes...... for information; and the prevalence and correlates of a favorable attitude toward deactivation. Three cohorts of ICD patients (n = 440) extracted from our institutional database were asked to complete a survey that included a vignette about deactivation near the end of life. Of the 440 patients approached, 294...

  9. Relation between emotional distress and heart rate variability in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Pedersen, Susanne S.; Theuns, Dominic A M J

    2014-01-01

    We investigated the relationship between Type D personality, depression, and anxiety, and heart rate variability (HRV) in 64 patients with an implantable cardioverter-defibrillator (ICD). HRV was obtained via 24-h Holter monitoring, and 24-h, 30-min daytime rest and 30-min nighttime sleep HRV were...... analyzed. In adjusted analyses, significant associations (standard deviation of normal-to-normal [NN] intervals [SDNN]: p = .043; standard deviation of NN intervals over 5-min periods [SDANN]: p = .010) and a trend (HRV triangular index: p = .09) were found for Type D personality, and trends were found...... = .043). A Benjamini-Hochberg correction for multiple testing led to reduction of the number of significant relationships, but there was still support for lower autonomic control patients with Type D personality and depression. Future research with larger sample sizes is warranted....

  10. Gender disparities in psychological distress and quality of life among patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Brouwers, Corline; van den Broek, Krista C; Denollet, Johan

    2011-01-01

    A subset of patients with an implantable cardioverter defibrillator (ICD) reports psychological distress and poor quality of life (QoL). Gender is one of the factors that has been proposed to explain individual differences in these outcomes. In this viewpoint, we (1) review the evidence for gender...... disparities in psychological distress and QoL in ICD patients by means of a systematic review, and (2) provide recommendations for future research and clinical implications. A systematic search of the literature identified 18 studies with a sample size ≥ 100 that examined gender disparities in anxiety....../depression and QoL in ICD patients (mean prevalence of women = 21%; mean age = 62 years). Our review shows that there is insufficient evidence to conclude that gender per se is a major autonomous predictor for disparities in psychological distress and QoL in ICD patients. Women had a higher prevalence of anxiety...

  11. Magnetic resonance imaging at 1.5-T in patients with implantable cardioverter-defibrillators.

    Science.gov (United States)

    Naehle, Claas P; Strach, Katharina; Thomas, Daniel; Meyer, Carsten; Linhart, Markus; Bitaraf, Sascha; Litt, Harold; Schwab, Jörg Otto; Schild, Hans; Sommer, Torsten

    2009-08-04

    Our aim was to establish and evaluate a strategy for safe performance of magnetic resonance imaging (MRI) at 1.5-T in patients with implantable cardioverter-defibrillators (ICDs). Expanding indications for ICD placement and MRI becoming the imaging modality of choice for many indications has created a growing demand for MRI in ICD patients, which is still considered an absolute contraindication. Non-pacemaker-dependent ICD patients with a clinical need for MRI were included in the study. To minimize radiofrequency-related lead heating, the specific absorption rate was limited to 2 W/kg. ICDs were reprogrammed pre-MRI to avoid competitive pacing and potential pro-arrhythmia: 1) the lower rate limit was programmed as low as reasonably achievable; and 2) arrhythmia detection was programmed on, but therapy delivery was programmed off. Patients were monitored using electrocardiography and pulse oximetry. All ICDs were interrogated before and after the MRI examination and after 3 months, including measurement of pacing capture threshold, lead impedance, battery voltage, and serum troponin I. Eighteen ICD patients underwent a total of 18 MRI examinations at 1.5-T; all examinations were completed safely. All ICDs could be interrogated and reprogrammed normally post-MRI. No significant changes of pacing capture threshold, lead impedance, and serum troponin I were observed. Battery voltage decreased significantly from pre- to post-MRI. In 2 MRI examinations, oversensing of radiofrequency noise as ventricular fibrillation occurred. However, no attempt at therapy delivery was made. MRI of non-pacemaker-dependent ICD patients can be performed with an acceptable risk/benefit ratio under controlled conditions by taking both MRI- and pacemaker-related precautions. (Implantable Cardioverter Defibrillators and Magnetic Resonance Imaging of the Heart at 1.5-Tesla; NCT00356239).

  12. General anaesthesia for insertion of an automated implantable cardioverter defibrillator in a child with Brugada and autism

    Directory of Open Access Journals (Sweden)

    Shwetal Goraksha

    2010-01-01

    Full Text Available A 14-year-old autistic boy presented with acute gastroenteritis and hypotension. The electrocardiogram showed a ventricular fibrillation rhythm - he went into cardiorespiratory arrest and was immediately resuscitated. On investigation, the electrocardiogram showed a partial right bundle branch block with a "coved" pattern of ST elevation in leads v 1 -v 3 . A provisional diagnosis of Brugada syndrome was made, for which an automated implantable cardioverter defibrillator (AICD implantation was advised. Although the automated implantable cardioverter defibrillator implantation is usually performed under sedation, because this was an autistic child, he needed general anaesthesia. We performed the procedure uneventfully under general anaesthesia and he was discharged after a short hospital stay.

  13. Relation between total shock energy and mortality in patients with implantable cardioverter-defibrillator.

    Science.gov (United States)

    Tenma, Taro; Yokoshiki, Hisashi; Mitsuyama, Hirofumi; Watanabe, Masaya; Mizukami, Kazuya; Kamada, Rui; Takahashi, Masayuki; Sasaki, Ryo; Maeno, Motoki; Okamoto, Kaori; Chiba, Yuki; Anzai, Toshihisa

    2018-05-15

    Implantable Cardioverter-Defibrillator (ICD) shocks have been associated with mortality. However, no study has examined the relation between total shock energy and mortality. The aim of this study is to assess the association of total shock energy with mortality, and to determine the patients who are at risk of this association. Data from 316 consecutive patients who underwent initial ICD implantation in our hospital between 2000 and 2011 were retrospectively studied. We collected shock energy for 3 years from the ICD implantation, and determined the relation of shock energy on mortality after adjusting confounding factors. Eighty-seven ICD recipients experienced shock(s) within 3 years from ICD implantation and 43 patients had died during the follow-up. The amount of shock energy was significantly associated with all-cause death [adjusted hazard ratio (HR) 1.26 (per 100 joule increase), p energy accumulation (≥182 joule) was lower (p energy accumulation (energy accumulation and all-cause death was remarkable in the patients with low left ventricular ejection fraction (LVEF ≤40%) or atrial fibrillation (AF). Increase of shock energy was related to mortality in ICD recipients. This relation was evident in patients with low LVEF or AF. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Time dependence of risks and benefits in pediatric primary prevention implantable cardioverter-defibrillator therapy.

    Science.gov (United States)

    DeWitt, Elizabeth S; Triedman, John K; Cecchin, Frank; Mah, Doug Y; Abrams, Dominic J; Walsh, Edward P; Gauvreau, Kimberlee; Alexander, Mark E

    2014-12-01

    Implantable cardioverter defibrillators (ICDs) used to prevent sudden cardiac arrest in children not only provide appropriate therapy in 25% of patients but also result in a significant incidence of inappropriate shocks and other device complications. ICDs placed for secondary prevention have higher rates of appropriate therapy than those placed for primary prevention. Pediatric patients with primary prevention ICDs were studied to determine time-dependent incidence of appropriate use and adverse events. A total of 140 patients aged prevention were retrospectively identified. Demographics and times to first appropriate shock; adverse events (including inappropriate shock, lead failure, reintervention, and complication); generator replacement and follow-up were noted. During mean follow-up of 4 years, appropriate shock occurred in 19% patients and first adverse event (excluding death/transplant) occurred in 36%. Risk of death or transplant was ≈1% per year and was not related to receiving appropriate therapy. Conditional survival analysis showed rates of appropriate therapy and adverse events decrease soon after implantation, but adverse events are more frequent than appropriate therapy throughout follow-up. Primary prevention ICDs were associated with appropriate therapy in 19% and adverse event in 36% in this cohort. The incidence of both first appropriate therapy and device-related adverse events decreased during longer periods of follow-up after implantation. This suggests that indications for continued device therapy in pediatric primary prevention ICD patients might be reconsidered after a period of nonuse. © 2014 American Heart Association, Inc.

  15. Congenital short QT syndrome and implantable cardioverter defibrillator treatment: inherent risk for inappropriate shock delivery.

    Science.gov (United States)

    Schimpf, Rainer; Wolpert, Christian; Bianchi, Francesca; Giustetto, Carla; Gaita, Florenzo; Bauersfeld, Urs; Borggrefe, Martin

    2003-12-01

    A congenital short QT interval constitutes a new primary electrical abnormality associated with syncope and/or sudden cardiac death. We report on the initial use of implantable cardioverter defibrillator (ICD) therapy in patients with inherited short QT interval and discuss sensing abnormalities and detection issues. In five consecutive patients from two unrelated European families who had structurally normal hearts, excessively shortened QT intervals, and a strong positive family history of sudden cardiac death, ICDs were placed for primary and secondary prevention. Mean QT intervals were 252 +/- 13 ms (QTc 287 +/- 13 ms). Despite normal sensing behavior during intraoperative and postoperative device testing, 3 of 5 patients experienced inappropriate shock therapies for T wave oversensing 30 +/- 26 days after implantation. Programming lower sensitivities and decay delays prevented further inappropriate discharges. The congenital short QT syndrome constitutes a new clinical entity with an increased risk for sudden cardiac death. Currently, ICD treatment is the only therapeutic option. In patients with short QT interval and implanted ICD, increased risk for inappropriate therapy is inherent due to the detection of short-coupled and prominent T waves. Careful testing of ICD function and adaptation of sensing levels and decay delays without sacrificing correct arrhythmia detection are essential.

  16. Infrequent physician use of implantable cardioverter-defibrillators risks patient safety.

    Science.gov (United States)

    Lyman, Stephen; Sedrakyan, Art; Do, Huong; Razzano, Renee; Mushlin, Alvin I

    2011-10-01

    Implantable cardioverter-defibrillators (ICDs) have diffused rapidly into clinical practice with little evaluation of their real-world effectiveness. To determine the effect of the adoption of ICD on patient safety, particularly with respect to physician volume and early outcomes. Retrospective cohort of all ICD implantations in New York state from 1997 to 2006, with follow-up at 90 days and 1 year. Setting New York state non-federal hospital discharges in which an ICD was implanted during the admission. Patients were followed forward for 1 year for subsequent admissions. Patients New York state residents undergoing ICD implantation. Effects of annual and career ICD implantation volume on 90-day complication, readmission, reprogramming, mortality and revision of the ICD within 1 year. This cohort (N = 38,992) represents a period of rapid adoption and implementation of this new technology, with frequency more than tripling between 1997 and 2006. We identified 6439 (16.5%) post-implantation complications and 1093 (2.8%) deaths within 90 days of implantation. The majority (73.4%) of physicians implanted one or fewer ICDs per year, and 11.0% of all implantations were performed by these very-low-volume operators. Patients treated by very-low-volume operators were more likely to die (RR = 1.8, 95% CI 1.3 to 2.4) or experience cardiac complications (RR = 4.7, 95% CI 3.3 to 6.8) even after the adjustment for case mix compared to operators who frequently performed ICD implantation. These findings suggest a need for safe and effective implementation strategies for new medical technologies, which minimize patient risk due to rapid diffusion among inexperienced providers and assure that the intended benefit can be maximised rapidly.

  17. Evidence of Cognitive Bias in Decision Making Around Implantable-Cardioverter Defibrillators: A Qualitative Framework Analysis.

    Science.gov (United States)

    Matlock, Daniel D; Jones, Jacqueline; Nowels, Carolyn T; Jenkins, Amy; Allen, Larry A; Kutner, Jean S

    2017-11-01

    Studies have demonstrated that patients with primary prevention implantable cardioverter-defibrillators (ICDs) often misunderstand the ICD. Advances in behavioral economics demonstrate that some misunderstandings may be due to cognitive biases. We aimed to explore the influence of cognitive bias on ICD decision making. We used a qualitative framework analysis including 9 cognitive biases: affect heuristic, affective forecasting, anchoring, availability, default effects, halo effects, optimism bias, framing effects, and state dependence. We interviewed 48 patients from 4 settings in Denver. The majority were male (n = 32). Overall median age was 61 years. We found frequent evidence for framing, default, and halo effects; some evidence of optimism bias, affect heuristic, state dependence, anchoring and availability bias; and little or no evidence of affective forecasting. Framing effects were apparent in overestimation of benefits and downplaying or omitting potential harms. We found evidence of cognitive bias in decision making for ICD implantation. The majority of these biases appeared to encourage ICD treatment. Published by Elsevier Inc.

  18. Risk of pacemaker or implantable cardioverter defibrillator after radiotherapy for early-stage breast cancer in Denmark, 1982-2005

    DEFF Research Database (Denmark)

    Rehammar, Jens Christian; Johansen, Jens Brock; Jensen, Maj-Britt

    2017-01-01

    BACKGROUND AND PURPOSE: To examine the risk of cardiac conduction abnormalities or severe ventricular arrhythmias requiring implantation of a cardiac implantable electronic device (CIED), either a pacemaker or an implantable cardioverter-defibrillator, subsequent to breast cancer (BC) radiotherapy...... (RT). MATERIAL AND METHODS: All women treated for early-stage BC in Denmark from 1982 to 2005 were identified from the Danish Breast Cancer Cooperative Group. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on CIED implants subsequent to RT. Standardized incidence...

  19. Psychometric properties of HeartQoL, a core heart disease-specific health-related quality of life questionnaire, in Danish implantable cardioverter defibrillator recipients

    DEFF Research Database (Denmark)

    Zangger, Graziella; Zwisler, Ann-Dorthe; Kikkenborg Berg, Selina

    2018-01-01

    disease-specific health-related quality of life questionnaire, in implantable cardioverter defibrillator recipients. Design This study involved cross-sectional and test-retest study designs. Method Implantable cardioverter defibrillator recipients in the cross-sectional study completed the Heart......QoL, the Short-Form 36 Health Survey, and the Hospital Anxiety and Depression Scale. The HeartQoL structure, construct-related validity (convergent and discriminative) and reliability (internal consistency) were assessed. HeartQoL reproducibility (test-retest) was assessed in an independent sample of implantable...... psychometric attributes of validity and reliability in this implantable cardioverter defibrillator population. This study adds support for the HeartQoL as a core heart-specific health-related quality of life questionnaire in a broad group of patients with heart disease including implantable cardioverter...

  20. Current use of implantable electrical devices in Sweden: data from the Swedish pacemaker and implantable cardioverter-defibrillator registry.

    Science.gov (United States)

    Gadler, Fredrik; Valzania, Cinzia; Linde, Cecilia

    2015-01-01

    The National Swedish Pacemaker and Implantable Cardioverter-Defibrillator (ICD) Registry collects prospective data on all pacemaker and ICD implants in Sweden. We aimed to report the 2012 findings of the Registry concerning electrical devices implantation rates and changes over time, 1 year complications, long-term device longevity and patient survival. Forty-four Swedish implanting centres continuously contribute implantation of pacemakers and ICDs to the Registry by direct data entry on a specific website. Clinical and technical information on 2012 first implants and postoperative complications were analysed and compared with previous years. Patient survival data were obtained from the Swedish population register database. In 2012, the mean pacemaker and ICD first implantation rates were 697 and 136 per million inhabitants, respectively. The number of cardiac resynchronization therapy (CRT) first implantations/million capita was 41 (CRT pacemakers) and 55 (CRT defibrillators), with only a slight increase in CRT-ICD rate compared with 2011. Most device implantations were performed in men. Complication rates for pacemaker and ICD procedures were 5.3 and 10.1% at 1 year, respectively. Device and lead longevity differed among manufacturers. Pacemaker patients were older at the time of first implant and had generally worse survival rate than ICD patients (63 vs. 82% after 5 years). Pacemaker and ICD implantation rates seem to have reached a level phase in Sweden. Implantable cardioverter-defibrillator and CRT implantation rates are very low and do not reflect guideline indications. Gender differences in CRT and ICD implantations are pronounced. Device and patient survival rates are variable, and should be considered when deciding device type. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  1. [Guidelines on the management of implantable cardioverter defibrillators at the end of life].

    Science.gov (United States)

    Datino, T; Rexach, L; Vidán, M T; Alonso, A; Gándara, Á; Ruiz-García, J; Fontecha, B; Martínez-Sellés, M

    2014-01-01

    This article is a joint document of the Spanish Society of Geriatrics and Gerontology, the Spanish Society of Palliative Care and the Section of Geriatric Cardiology of the Spanish Society of Cardiology. Its aim is to address the huge gap that exists in Spain with regard to the management of implantable cardioverter defibrillators (ICDs) in the final stages of life. It is increasingly common to find patients carrying these devices that are in the terminal stage of an advanced disease. This occurs in patients with advanced heart disease and subsequent heart failure refractory to treatment but also in a patient with an ICD who develops cancer disease, organ failure or other neurodegenerative diseases with poor short-term prognosis. The vast majority of these patients are over 65, so the paper focuses particularly on the elderly who are in this situation, but the decision-making process is similar in younger patients with ICDs who are in the final phase of their life. Copyright © 2013 SEGG. Published by Elsevier Espana. All rights reserved.

  2. Guidelines on the management of implantable cardioverter defibrillators at the end of life.

    Science.gov (United States)

    Datino, T; Rexach, L; Vidán, M T; Alonso, A; Gándara, Á; Ruiz-García, J; Fontecha, B; Martínez-Sellés, M

    2014-01-01

    This article is a joint document of the Spanish Society of Geriatrics and Gerontology, the Spanish Society of Palliative Care and the Section of Geriatric Cardiology of the Spanish Society of Cardiology. Its aim is to address the huge gap that exists in Spain with regard to the management of implantable cardioverter defibrillators (ICDs) in the final stages of life. It is increasingly common to find patients carrying these devices that are in the terminal stage of an advanced disease. This occurs in patients with advanced heart disease and subsequent heart failure refractory to treatment but also in a patient with an ICD who develops cancer disease, organ failure or other neurodegenerative diseases with poor short-term prognosis. The vast majority of these patients are over 65, so the paper focuses particularly on the elderly who are in this situation, but the decision-making process is similar in younger patients with ICDs who are in the final phase of their life. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  3. How does an implantable cardioverter defibrillator (ICD) affect the lives of patients and their families?

    Science.gov (United States)

    Eckert, Marion; Jones, Tina

    2002-06-01

    This study aimed to identify the lived experience of patients with implantable cardioverter defibrillators (ICD) and their families. The methodology used was interpretative phenomenology. Unstructured interviews were conducted with three family members and three ICD recipients. Using a methodological approach outlined by van Manen, the participants transcribed texts were analysed looking for similar concepts and ideas that developed into themes that explicated the meaning of this phenomena. The themes that emerged were: dependence, which encompassed their perceptions about the life-saving device; the memory of their first defibrillation experience; lifestyle changes, which incorporated modification techniques; lack of control, which highlighted feelings such as fear, anxiety and powerlessness; mind game, which illustrated psychological challenges; and the issue of security, demonstrating how 'being there' and not 'being there' impacted on their everyday lives. The long-term outcomes of living with an ICD are important considerations for all health-care providers. This research highlights the everyday activities of recipients, the lifestyle changes they have made, the emotional significance of the device and the psychological coping strategies that the participants have adopted. The findings of this research will allow health-care professionals to be better prepared to provide education and support for ICD recipients and their families in regards to issues related to insertion of the device during the postinsertion recovery period and for long-term management after hospital discharge.

  4. Interference of neodymium magnets with cardiac pacemakers and implantable cardioverter-defibrillators: an in vitro study.

    Science.gov (United States)

    Ryf, Salome; Wolber, Thomas; Duru, Firat; Luechinger, Roger

    2008-01-01

    Permanent magnets may interfere with the function of cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). Neodymium-iron-boron (NdFeB) magnets have become widely available in recent years and are incorporated in various articles of daily life. We conducted an in-vitro study to evaluate the ability of NdFeB magnets for home and office use to cause interference with cardiac pacemakers and ICDs. The magnetic fields of ten NdFeB magnets of different size and shape were measured at increasing distances beginning from the surface until a field-strength (B-field) value of 0.5 mT was reached. Furthermore, for each magnet the distance was determined at which a sample pacemaker switched from magnet mode to normal mode. Depending on the size and remanence of individual magnets, a B-field value of 0.5 mT was found at distances ranging from 1.5 cm to 30 cm and a value of 1 mT at distances from 1 cm to 22 cm. The pacemaker behavior was influenced at distances from 1 cm to 24 cm. NdFeB magnets for home and office use may cause interference with cardiac pacemakers and ICDs at distances up to 24 centimeters. Patient education and product declarations should include information about the risk associated with these magnets.

  5. Potential interference of small neodymium magnets with cardiac pacemakers and implantable cardioverter-defibrillators.

    Science.gov (United States)

    Wolber, Thomas; Ryf, Salome; Binggeli, Christian; Holzmeister, Johannes; Brunckhorst, Corinna; Luechinger, Roger; Duru, Firat

    2007-01-01

    Magnetic fields may interfere with the function of cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). Neodymium-iron-boron (NdFeB) magnets, which are small in size but produce strong magnetic fields, have become widely available in recent years. Therefore, NdFeB magnets may be associated with an emerging risk of device interference. We conducted a clinical study to evaluate the potential of small NdFeB magnets to interfere with cardiac pacemakers and ICDs. The effect of four NdFeB magnets (two spherical magnets 8 and 10 mm in diameter, a necklace made of 45 spherical magnets, and a magnetic name tag) was tested in forty-one ambulatory patients with a pacemaker and 29 patients with an ICD. The maximum distance at which the magnetic switch of a device was influenced was observed. Magnetic interference was observed in all patients. The maximum distance resulting in device interference was 3 cm. No significant differences were found with respect to device manufacturer and device types. Small NdFeB magnets may cause interference with cardiac pacemakers and ICDs. Patients should be cautioned about the interference risk associated with NdFeB magnets during daily life.

  6. Cardiac e-learning: Development of a web-based implantable cardioverter defibrillator educational system.

    Science.gov (United States)

    Hickey, Kathleen T; Johnson, Mary P; Biviano, Angelo; Aboelela, Sally; Thomas, Tami; Bakken, Suzanne; Garan, Hasan; Zimmerman, John L; Whang, William

    2011-04-01

    The objective of this study was to design a Web-based implantable cardioverter defibrillator (ICD) module that would allow greater access to learning which could occur at an individual's convenience outside the fast-paced clinical environment. A Web-based ICD software educational program was developed to provide general knowledge of the function of the ICD and the interpretation of the stored electrocardiograms. This learning tool could be accessed at any time via the Columbia University Internet server, using a unique, password protected login. A series of basic and advanced ICD terms were presented using actual ICD screenshots and videos that simulated scenarios the practitioner would most commonly encounter in the fast-paced clinical setting. To determine the usefulness of the site and improve the module, practitioners were asked to complete a brief (less than 5 min) online survey at the end of the module. Twenty-six practitioners have logged into our Web site: 20 nurses/nurse practitioners, four cardiac fellows, and two other practitioners. The majority of respondents rated the program as easy to use and useful. The success of this module has led to it becoming part of the training for student nurse practitioners before a clinical electrophysiology rotation, and the module is accessed by our cardiac entry level fellows before a rotation in the intensive care unit or electrophysiology service. Remote electronic arrhythmia learning is a successful example of the melding of technology and education to enhance clinical learning.

  7. Higher defibrillation threshold in methamphetamine cardiomyopathy patients with implantable cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Rakesh Malhotra

    2017-11-01

    Full Text Available Introduction: Identification of patients with an increased risk of high defibrillation thresholds (DFTs is important in planning implantable cardioverter-defibrillator (ICD procedures. Clinical observations have suggested that patients with methamphetamine cardiomyopathy (MACMP have significantly elevated defibrillation thresholds. We hypothesized that MACMP patients would have higher DFT thresholds than controls and would require procedural changes during ICD implantation to accommodate higher thresholds. Methods: We identified consecutive patients with MACMP undergoing ICD implantation at the academic center from 2003 to 2007. We then compared DFTs against age-and sex-matched controls. Results: The MACMP (n = 10 group showed significantly increased DFT thresholds (23.7 ± 6.7 J compared with age and sex-matched controls (14.5 ± 4.6 J, p < 0.005. Additionally, patients with MACMP had evidence of more severe congestive heart failure, with increased B-type natrieutic protein (BNP levels (1173 ± 784 vs 260 ± 349, p = 0.02 and decreased left ventricular ejection fraction (LVEF (17.8 ± 9.4 vs 35.9 ± 15.2, p = 0.02. MACMP patients required high output devices than controls (50% versus 0%, p = 0.03. Differences between groups remained significant despite adjusting for LVEF. Conclusions: Planning for ICD implantation should take into consideration a history of methamphetamine abuse, mandating DFT testing and empiric consideration of high output devices for such patients. Keywords: Methamphetamine cardiomyopathy, Implantable cardioverter-defibrillatior, Defibrillation threshold testing, B-type natriuretic peptide, Ejection fraction

  8. Prognosis after implantation of cardioverter-defibrillators in Korean patients with Brugada syndrome.

    Science.gov (United States)

    Son, Myoung Kyun; Byeon, Kyeongmin; Park, Seung-Jung; Kim, June Soo; Nam, Gi-Byoung; Choi, Kee-Joon; Kim, You-Ho; Park, Sang Weon; Kim, Young-Hoon; Park, Hyung Wook; Cho, Jeong Gwan; On, Young Keun

    2014-01-01

    Our study aims to analyze prognosis after implantable cardioverter-defibrillator (ICD) implantation in Korean patients with Brugada syndrome (BrS). This was a retrospective study of BrS patients implanted with an ICD at one of four centers in Korea between January 1998 and April 2012. Sixty-nine patients (68 males, 1 female) were implanted with an ICD based on aborted cardiac arrest (n=38, 55%), history of syncope (n=17, 25%), or induced ventricular tachyarrhythmia on electrophysiologic study in asymptomatic patients (n=14, 20%). A family history of sudden cardiac death and a spontaneous type 1 electrocardiography (ECG) were noted in 13 patients (19%) and 44 patients (64%), respectively. During a mean follow-up of 59±46 months, 4.6±5.5 appropriate shocks were delivered in 19 patients (28%). Fourteen patients (20%) experienced 5.2±8.0 inappropriate shocks caused by supraventricular arrhythmia, lead failure, or abnormal sensing. Six patients were admitted for cardiac causes during follow-up, but no cardiac deaths occurred. An episode of aborted cardiac arrest was a significant predictor of appropriate shock, and the composite of cardiac events in the Cox proportional hazard model [hazard ratio (95% confidence interval) was 11.34 (1.31-97.94) and 4.78 (1.41-16.22), respectively]. However, a spontaneous type 1 ECG was not a predictor of cardiac events. Appropriate shock (28%) and inappropriate shock (20%) were noted during a mean follow-up of 59±46 months in Korean BrS patients implanted with an ICD. An episode of aborted cardiac arrest was the most powerful predictor of cardiac events.

  9. Complications and Mortality of Single Versus Dual Chamber Implantable Cardioverter Defibrillators

    Directory of Open Access Journals (Sweden)

    Ataallah Bagherzadeh

    2006-04-01

    Full Text Available Background: The implantable cardioverter defibrillators (ICDs are increasingly being used as a treatment modality for life threatening tachyarrhythmia. The purpose of this study was to compare the frequency of complications and mortality between single-chamber and dual-chamber ICD implantation in Shahid Rajaie cardiovascular center. Methods and results: Between January 2000 and December 2004, 234 patients received ICD by a percutaneous transvenous approach and were followed for 33 ± 23 months. The cumulative incidence of complications was 9.4% over the follow-up period. There was no significant difference in overall complication rate between single chamber (VR and dual chamber (DR ICD groups in the follow-up period (P= 0.11. The risk of complications did not have any statistically significant difference in secondary versus primary prevention groups (P=0.06. The complications were not associated with the severity of left ventricular systolic dysfunction (P=0.16.The frequency of lead-related complications was higher in dual chamber ICDs in comparison with single chamber ICDs (P=0.02. There was no significant difference in mortality between different sex groups (P=0.37, different indications for ICD implantation (P=0.43 or between VR and DR ICD groups (P= 0.55. Predictors of mortality were NYHA class III or more (P65 years (P=0.011 and LVEF<30% (P<0.001. The mortality in patients with CAD and DCM were significantly higher than those with other structural heart diseases (P=0.001. Conclusions: Close monitoring of patients during the first 2 month after ICD implantation is recommended because the majority of complications occur early after the procedure.

  10. Management of patients with implantable cardioverter-defibrillators and pacemakers who require radiation therapy.

    Science.gov (United States)

    Brambatti, Michela; Mathew, Rebecca; Strang, Barbara; Dean, Joan; Goyal, Anuja; Hayward, Joseph E; Long, Laurene; DeMeis, Patty; Smoke, Marcia; Connolly, Stuart J; Morillo, Carlos A; Amit, Guy; Capucci, Alessandro; Healey, Jeff S

    2015-10-01

    Radiation therapy (RT) may pose acute and long-term risks for patients with cardiac implantable electronic devices (CIEDs), including pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs). However, the frequency of these problems has not been accurately defined. The purpose of this study was to determine the prevalence of CIEDs among patients requiring RT and report the common CIED-related problems when patients are managed according to a standard clinical care path. In a single tertiary-care center, we prospectively screened all patients requiring RT and identified patients with ICDs or PMs. We collected clinical data about their cancer, RT treatment plan, and CIED. Radiation dose to the device was estimated in all patients, and any device malfunction during RT was documented. Of the 34,706 consecutive patients receiving RT, 261 patients (0.8%, mean age 77.9 ± 9.4 years) had an implantable cardiac device: 54 (20.7%) ICDs and 207 (79.3%) PMs. The site of RT was head and neck (27.4%), chest (30.0%), and abdomen/pelvis (32.6%). Using our care path, 63.2% of patients required continuous cardiac monitoring, 14.6% required device reprogramming, 18.8% required magnet application during RT, and 3.4% required device repositioning to the contralateral side before RT. Four patients (1.5%) had inappropriate device function during RT: 3 experienced hemodynamically tolerated ventricular pacing at the maximum sensor rate, and 1 experienced a device power-on-reset. No patient died or suffered permanent device failure. Nearly 1% of patients receiving RT in this series has a PM or ICD. However, with a systematic policy of risk assessment and patient management, significant device-related complications are rare. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  11. Diagnosis and therapy of atrial tachyarrhythmias in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-11-01

    Devices capable of monitoring and treating atrial tachyarrhythmias provide information about the natural history of the arrhythmias and potentially can influence their natural course by electrical therapy early after onset. Types of atrial arrhythmias and efficacy of device therapies were evaluated in 30 patients implanted with the Medtronic model 7250 Jewel AF implantable cardioverter defibrillator (ICD). All patients had structural heart disease and documented sustained ventricular and atrial arrhythmias (27 with atrial fibrillation [AF]) before implant. Twenty patients were taking amiodarone, and three were taking sotalol. During 20+/-10 months of follow-up, 600 atrial arrhythmia recurrences were documented in 50% of patients. AF was diagnosed in 19%, fast polymorphic atrial tachycardia (AT) in 20%, fast monomorphic AT in 57%, and slow AT in 4% of episodes. The two adaptive pacing therapies, burst and ramp, together with the 50-Hz burst, were successful in 57% of detected atrial arrhythmias. Burst and ramp were responsible for 49% and 50-Hz burst for 51% of successfully treated arrhythmias; 33% of the episodes terminated spontaneously. No ventricular proarrhythmia was observed due to atrial pacing therapies. In 30% of episodes, dual chamber pacing was required due to post termination bradycardia. Atrial arrhythmia recurrences in patients with dilated cardiomyopathy were not amenable to pacing therapies. Several aspects of atrial arrhythmia diagnosis, therapy, and documentation that are specific for functioning of the Jewel AF are discussed. Atrial arrhythmias in ICD patients with diseased hearts who are taking Class III antiarrhythmics frequently had longer cycle lengths than AF. Half of these arrhythmias could be terminated with pacing therapies; one third terminated spontaneously.

  12. Low risk of electromagnetic interference between smartphones and contemporary implantable cardioverter defibrillators.

    Science.gov (United States)

    Burri, Haran; Mondouagne Engkolo, Louis Paulin; Dayal, Nicolas; Etemadi, Abdul; Makhlouf, Anne-Marie; Stettler, Carine; Trentaz, Florence

    2016-05-01

    Manufacturers of implantable cardioverter defibrillators (ICDs) recommend that cell phones be maintained at a distance of ∼15 cm from the implanted device in order to avoid risk of dysfunction due to electromagnetic interference (EMI). Data relating to this issue are outdated and do not reflect modern technology. Our aim was to evaluate whether EMI is still an issue with contemporary ICDs and smartphones. Consecutive patients implanted with a wireless-enabled ICD were tested for potential interference with two models of recent 4G smartphones in conditions intended to maximize risk of EMI. A magnet effect (due to the phone speakers) was tested by placing the smartphones in the standby mode directly over the ICD generator. The presence of EMI artefacts on the real-time electrograms was evaluated by placing the smartphones in the standby, dialling, and operating modes directly over the generator casing and over the parasternal region in the vicinity of the ventricular lead. A total of 63 patients equipped with 29 different models of single, dual, or biventricular ICDs from five major manufacturers were included. None of the patients showed any evidence of interference with the smartphones during any of the 882 tests. The risk of EMI between modern smartphones and contemporary ICDs is low. This is probably due to the filters incorporated in the ICDs and low emission by the phones, as well as the small size of the magnets in the smartphones tested. NCT02330900 (http://www.clinicaltrials.gov). Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  13. Feedback to providers improves evidence-based implantable cardioverter-defibrillator programming and reduces shocks.

    Science.gov (United States)

    Silver, Marc T; Sterns, Laurence D; Piccini, Jonathan P; Joung, Boyoung; Ching, Chi-Keong; Pickett, Robert A; Rabinovich, Rafael; Liu, Shufeng; Peterson, Brett J; Lexcen, Daniel R

    2015-03-01

    Implantable cardioverter-defibrillator (ICD) shocks are associated with increased anxiety, health care utilization, and potentially mortality. The purpose of the Shock-Less Study was to determine if providing feedback reports to physicians on their adherence to evidence-based shock reduction programming could improve their programming behavior and reduce shocks. Shock-Less enrolled primary prevention (PP) and secondary prevention (SP) ICD patients between 2009 and 2012 at 118 study centers worldwide and followed patients longitudinally after their ICD implant. Center-specific therapy programming reports (TPRs) were delivered to each center 9 to 12 months after their first enrollment. The reports detailed adherence to evidence-based programming targets: number of intervals to detect ventricular fibrillation (VF NID), longest treatment interval (LTI), supraventricular tachycardia (SVT) discriminators (Wavelet, PR Logic), SVT limit, Lead Integrity Alert (LIA), and antitachycardia pacing (ATP). Clinicians programmed ICDs at their discretion. The primary outcome measure was the change in utilization of evidence-based shock reduction programming before (phase I, n = 2694 patients) and after initiation of the TPR (phase II, n = 1438 patients). Patients implanted after feedback reports (phase II) were up to 20% more likely to have their ICDs programmed in line with evidence-based shock reduction programming (eg, VF NID in PP patients 30/40 in 33.5% vs 18.6%, P programming feedback reports improves adherence to evidence-based shock reduction programming and is associated with lower risk of ICD shocks. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  14. Influence of radiotherapy on the latest generation of implantable cardioverter-defibrillators

    International Nuclear Information System (INIS)

    Hurkmans, Coen W.; Scheepers, Egon; Springorum, Bob G.F.; Uiterwaal, Hans

    2005-01-01

    Purpose: Radiotherapy can influence the functioning of pacemakers and implantable cardioverter-defibrillators (ICDs). ICDs offer the same functionality as pacemakers, but are also able to deliver a high-voltage shock to the heart if needed. Guidelines for radiotherapy treatment of patients with an implanted rhythm device have been published in 1994 by The American Association of Physicists in Medicine, and are based only on experience with pacemakers. Data on the influence of radiotherapy on ICDs are limited. The objective of our study is to determine the influence of radiotherapy on the latest generation of ICDs. Methods and Materials: Eleven modern ICDs have been irradiated in our department. The irradiation was performed with a 6-MV photon beam. The given dose was fractionated up to a cumulative dose of 120 Gy. Two to 5 days passed between consecutive irradiations. Frequency, output, sensing, telemetry, and shock energy were monitored. Results: Sensing interference by ionizing radiation on all ICDs has been demonstrated. For four ICDs, this would have caused the inappropriate delivery of a shock because of interference. At the end of the irradiation sessions, all devices had reached their point of failure. Complete loss of function was observed for four ICDs at dose levels between 0.5 Gy and 1.5 Gy. Conclusions: The effect of radiation therapy on the newest generation of ICDs varies widely. If tachycardia monitoring and therapy are functional (programmed on) during irradiation, the ICD might inappropriately give antitachycardia therapy, often resulting in a shock. Although most ICDs did not fail below 80 Gy, some devices had already failed at doses below 1.5 Gy. Guidelines are formulated for the treatment of patients with an ICD

  15. Outcomes with single-coil versus dual-coil implantable cardioverter defibrillators: a meta-analysis.

    Science.gov (United States)

    Sunderland, Nicholas; Kaura, Amit; Murgatroyd, Francis; Dhillon, Para; Scott, Paul A

    2018-03-01

    Dual-coil implantable cardioverter defibrillator (ICD) leads have traditionally been used over single-coil leads due to concerns regarding high defibrillation thresholds (DFT) and consequent poor shock efficacy. However, accumulating evidence suggests that this position may be unfounded and that dual-coil leads may also be associated with higher complication rates during lead extraction. This meta-analysis collates data comparing dual- and single-coil ICD leads. Electronic databases were systematically searched for randomized controlled trials (RCT) and non-randomized studies comparing single-coil and dual-coil leads. The mean differences in DFT and summary estimates of the odds-ratio (OR) for first-shock efficacy and the hazard-ratio (HR) for all-cause mortality were calculated using random effects models. Eighteen studies including a total of 138,124 patients were identified. Dual-coil leads were associated with a lower DFT compared to single coil leads (mean difference -0.83J; 95% confidence interval [CI] -1.39--0.27; P = 0.004). There was no difference in the first-shock success rate with dual-coil compared to single-coil leads (OR 0.74; 95%CI 0.45-1.21; P=0.22). There was a significantly lower risk of all-cause mortality associated with single-coil leads (HR 0.91; 95%CI 0.86-0.95; P dual-coil leads. The mortality benefit with single-coil leads most likely represents patient selection bias. Given the increased risk and complexity of extracting dual-coil leads, centres should strongly consider single-coil ICD leads as the lead of choice for routine new left-sided ICD implants. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  16. Optimizing implantable cardioverter-defibrillator treatment of rapid ventricular tachycardia: antitachycardia pacing therapy during charging.

    Science.gov (United States)

    Schoels, Wolfgang; Steinhaus, David; Johnson, W Ben; O'hara, Gilles; Schwab, Joerg O; Jenniskens, Inge; Degroot, Paul J; Tang, Feng; Helmling, Erhard

    2007-07-01

    Previous studies in implantable cardioverter-defibrillator (ICD) patients demonstrated the efficacy and safety of antitachycardia pacing (ATP) for rapid ventricular tachycardias (VT). To prevent shock delay in case of ATP failure, a new feature (ATP during charging) was developed to deliver ATP for rapid VT while charging for shock. The purpose of this study was to determine the efficacy and safety of this new feature. In a prospective, nonrandomized trial, patients with standard ICD indication received an EnTrust ICD. VT and ventricular fibrillation (VF) episodes were reviewed for appropriate detection, ATP success, rhythm acceleration, and related symptoms. In 421 implanted patients, 116 VF episodes occurred in 37 patients. Eighty-four (72%) episodes received ATP during or before charging. ATP prevented a shock in 58 (69%) of 84 episodes in 15 patients. ATP stopped significantly more monomorphic (77%) than polymorphic VTs (44%, P = .05). Five (6%) episodes accelerated after ATP but were terminated by the backup shock(s). No symptoms were related to ATP during charging. In four patients, 38 charges were saved by delivering ATP before charging. Of 98 induced VF episodes, 28% were successfully terminated by ATP versus 69% for spontaneous episodes (P <.01). Most VTs detected in the VF zone can be painlessly terminated by ATP delivered during charging, with a low risk of acceleration or symptoms. ATP before charging allows delivery of two ATP attempts before shock in the same time that would otherwise be required to deliver only one ATP plus a shock. It also offers potential battery energy savings.

  17. Cognitive behavioral therapy (CBT in a Patient with Implantable Cardioverter Defibrillator (ICD and Posttraumatic stress disorder(PTSD.

    Directory of Open Access Journals (Sweden)

    Sahar Ansari

    2014-09-01

    Full Text Available The implantable cardioverter defibrillator (ICD has currently become the standard treatment for preventing sudden cardiac death. There are some psychological consequences in patients with ICD such as posttraumatic stress disorder (PTSD after the shocks induced by ICD. This report aimed to present the case of a 54-year-old man with ICD who had developed PTSD; his PTSD was treated, using cognitive-behavioral psychotherapy consisting of relaxation, mindfulness and problem solving techniques. In patients with ICD who are experiencing PTSD using cognitive behavioral interventions may be helpful to reduce their psychological sufferings.

  18. Sustaining cyborgs: sensing and tuning agencies of pacemakers and implantable cardioverter defibrillators.

    Science.gov (United States)

    Oudshoorn, Nelly

    2015-02-01

    Recently there has been a renewed interest in cyborgs, and particularly in new and emerging fusions of humans and technologies related to the development of human enhancement technologies. These studies reflect a trend to follow new and emerging technologies. In this article, I argue that it is important to study 'older' and more familiar cyborgs as well. Studying 'the old' is important because it enables us to recognize hybrids' embodied experiences. This article addresses two of these older hybrids: pacemakers and implantable cardioverter defibrillators inserted in the bodies of people suffering from heart-rhythm disturbances. My concern with hybrid bodies is that internal devices seem to present a complex and neglected case if we wish to understand human agency. Their 'users' seem to be passive because they cannot exert any direct control over the working of their devices. Technologies inside bodies challenge a longstanding tradition of theorizing human-technology relations only in terms of technologies external to the body. Cyborg theory is problematic as well because most studies tend to conceptualize the cyborg merely as a discursive entity and silence the voices of people living as cyborgs. Inspired by feminist research that foregrounds the materiality of the lived and intimate relations between bodies and technologies, I argue that creating these intimate relations requires patients' active involvement in sustaining their hybrid bodies. Based on observations of these monitoring practices in a Dutch hospital and interviews with patients and technicians, the article shows that heart cyborgs are far from passive. On the contrary, their unique experience in sensing the entangled agencies of technologies and their own heart plays a crucial role in sustaining their hybrid bodies.

  19. Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-12-01

    Performance of dual chamber implantable cardioverter defibrillator (ICD) systems has been judged based on functioning of the ventricular tachycardia:supraventricular tachycardia (VT:SVT) discrimination criteria and DDD pacing. The purpose of this study was to evaluate the use of dual chamber diagnostics to improve the electrical and antiarrhythmic therapy of ventricular arrhythmias. Information about atrial and ventricular rhythm in relation to ventricular arrhythmia occurrence and therapy was evaluated in 724 spontaneous arrhythmia episodes detected and treated by three types of dual chamber ICDs in 41 patients with structural heart disease. Device programming was based on clinically documented and induced ventricular arrhythmias. In ambulatory patients, sinus tachycardia preceded ventricular arrhythmias more often than in the hospital during exercise testing. The incidence of these VTs could be reduced by increasing the dose of a beta-blocking agent in only two patients. In five patients in whom sinus tachycardia developed after onset of hemodynamic stable VT, propranolol was more effective than Class III antiarrhythmics combined with another beta-blocking agent with regard to the incidence of VT and pace termination. In all but three cases, atrial arrhythmias were present for a longer time before the onset of ventricular arrhythmias. During atrial arrhythmias, fast ventricular rates before the onset of ventricular rate were observed more often than RR irregularities and short-long RR sequences. Dual chamber diagnostics allowed proper interpretation of detection and therapy outcome in patients with different types of ventricular arrhythmia. The advantages of the dual chamber ICD system go further than avoiding the shortcomings of the single chamber system. Information from the atrial chamber allows better device programming and individualization of drug therapy for ventricular arrhythmia.

  20. Digoxin Is Associated With Increased Shock Events and Electrical Storms in Patients With Implantable Cardioverter Defibrillators.

    Science.gov (United States)

    Mina, George S; Acharya, Madan; Shepherd, Taylor; Gobrial, George; Tekeste, Michael; Watti, Hussam; Bhandari, Ruchi; Saini, Aditya; Reddy, Pratap; Dominic, Paari

    2018-03-01

    Recently, digoxin use has been found to associate with higher mortality. Yet, potential mechanisms by which digoxin use increases mortality remain unclear. Increased arrhythmogenicity from digoxin use is one possibility. Thus, we aimed to evaluate the relation between digoxin and shock events in patients with implantable cardioverter defibrillators (ICDs). We performed a retrospective chart review of all patients with ICDs and at least 1 device interrogation at our institution between January 1, 2012, and January 1, 2015. We aimed to cover 1 year of interrogation period. Patients with heart failure, atrial fibrillation, or both were included in the analysis. Patients were divided into 2 groups based on digoxin use, defined as use of digoxin for any period of time during ICD interrogation period. Incidence of ICD shock events and electrical storms and hospitalizations were compared between the 2 groups. The study included 202 patients. Of those, 55 patients were on digoxin and 147 were not on digoxin. Patients on digoxin were more likely to receive ICD shocks (odds ratio [OR] = 2.5, 95% confidence interval [95% CI] = 1.01-6.18, P = .04) and have increased risk of electrical storms ( P = .02). Moreover, total hospitalizations were higher in digoxin users ( P = .02). Multivariate logistic regression analysis also showed that digoxin use was an independent predictor of shock events (OR = 4.07, 95% CI = 1.43-11.58, P = .009). Digoxin is associated with increased shock events and electrical storms in patients with ICDs; however, large randomized controlled studies are needed to confirm our findings.

  1. Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure.

    Science.gov (United States)

    Gunderson, Bruce D; Gillberg, Jeffrey M; Wood, Mark A; Vijayaraman, Pugazhendhi; Shepard, Richard K; Ellenbogen, Kenneth A

    2006-02-01

    Implantable cardioverter-defibrillator (ICD) lead failures often present as inappropriate shock therapy. An algorithm that can reliably discriminate between ventricular tachyarrhythmias and noise due to lead failure may prevent patient discomfort and anxiety and avoid device-induced proarrhythmia by preventing inappropriate ICD shocks. The goal of this analysis was to test an ICD tachycardia detection algorithm that differentiates noise due to lead failure from ventricular tachyarrhythmias. We tested an algorithm that uses a measure of the ventricular intracardiac electrogram baseline to discriminate the sinus rhythm isoelectric line from the right ventricular coil-can (i.e., far-field) electrogram during oversensing of noise caused by a lead failure. The baseline measure was defined as the product of the sum (mV) and standard deviation (mV) of the voltage samples for a 188-ms window centered on each sensed electrogram. If the minimum baseline measure of the last 12 beats was algorithm to detect lead failures. The minimum baseline measure for the 24 lead failure episodes (0.28 +/- 0.34 mV-mV) was smaller than the 135 ventricular tachycardia (40.8 +/- 43.0 mV-mV, P <.0001) and 55 ventricular fibrillation episodes (19.1 +/- 22.8 mV-mV, P <.05). A minimum baseline <0.35 mV-mV threshold had a sensitivity of 83% (20/24) with a 100% (190/190) specificity. A baseline measure of the far-field electrogram had a high sensitivity and specificity to detect lead failure noise compared with ventricular tachycardia or fibrillation.

  2. Adherence to an Aerobic Exercise Intervention after an Implantable Cardioverter Defibrillator (ICD).

    Science.gov (United States)

    Dougherty, Cynthia M; Luttrell, Matilda N; Burr, Robert L; Kim, Misun; Haskell, William L

    2016-02-01

    Exercise adherence is an important element in achieving important exercise outcomes. The purpose of this study was to describe adherence in a home-based aerobic exercise program following an implantable cardioverter defibrillator (ICD), determine effects of adherence on peakVO2 , and outline reasons for nonadherence. A single-blind randomized control trial of home walking compared to usual care in 160 patients with an ICD for primary or secondary prevention was conducted. This report is on adherence in the exercise arm (N = 84). Home walking exercise consisted of 8 weeks of aerobic conditioning (60 minutes/day, 5 days/week) followed by 16 weeks of aerobic maintenance (150 minutes/week, 30 minutes/session) at 60-80% of heart rate reserve. Adherence was tracked using Polar heart rate (HR) monitors, pedometers, home exercise logs, and telephone follow-up. Adherence was defined as performing at least 80% of prescribed exercise. For aerobic conditioning, there was a mean frequency of 3.81 walks/week, duration of 1,873 minutes walked, and 17.5% of exercise was in the target HR (THR) zone. For aerobic maintenance, there was a mean frequency of 2.4 walks/week, duration of 1,872 minutes/walked, and 8.7% of exercise was in the THR zone. Those who were 80% adherent achieved a 3.4 mL/kg/min (P = 0.03) improvement in peakVO2 over those who were exercise ranged from scheduling issues to viral illness and fatigue. Adherence to aerobic exercise frequency and duration was high with few dropouts, resulting in higher peakVO2 . Exercise monitoring equipment encouraged adherence and conferred a sense of safety to exercise. ©2015 Wiley Periodicals, Inc.

  3. Implantable cardioverter-defibrillator explantation for overdiagnosed or overtreated congenital long QT syndrome.

    Science.gov (United States)

    Gaba, Prakriti; Bos, J Martijn; Cannon, Bryan C; Cha, Yong-Mei; Friedman, Paul A; Asirvatham, Samuel J; Ackerman, Michael J

    2016-04-01

    Primary treatment of long QT syndrome (LQTS) currently consists of beta-blocker therapy, although an implantable cardioverter-defibrillator (ICD) is considered for high-risk patients. However, both overdiagnosis and overtreatment must be avoided because their sequelae can be significant. The purpose of this study was to evaluate the prevalence and details of ICD explants in a cohort of patients from a tertiary genetic heart rhythm clinic for a previously rendered diagnosis of LQTS. Overall, 1227 consecutive patients were included in the study. All patients had been referred to the Mayo Clinic for evaluation of possible LQTS and subsequently were either diagnosed with LQTS or dismissed as normal. Further stratification of patients was conducted to assess how many patients had an ICD and how many had a subsequent ICD explant. In total, 170 patients (14%) had an ICD, including 157 of 670 patients (23%) with confirmed LQTS and 13 of 557 patients (2%) who did not have LQTS. Among these, 12 of 1227 (1%) had the ICD removed: 7 of 157 LQTS patients (4.5%) compared to 5 of 14 non-LQTS patients (36%). Before explant, 5 of 12 patients (42%) experienced inappropriate shocks, ranging from 2 to as many as 54 shocks. In addition, 4 had a device-related infection, and 9 had device malfunction (including lead dysfunction or fracture). None of these patients had a breakthrough cardiac event since removal of their ICD during 5.5 ± 3.5 years of follow-up. Implications of overdiagnosis and overtreatment are profound because unnecessary ICD placement can be associated with infection, malfunction, inappropriate shocks, and subsequent anxiety. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  4. Psychological and clinical problems in young adults with implantable cardioverter-defibrillators.

    Science.gov (United States)

    Wójcicka, Mariola; Lewandowski, Michał; Smolis-Bak, Edyta; Szwed, Hanna

    2008-10-01

    Implantable cardioverter-defibrillators (ICD) are the most effective treatment in patients with the risk of sudden cardiac death. ICD improves patients' safety but is also the source of numerous inconveniences. Especially young people consider such ICD-related inconveniences as most unwelcome. To assess the quality of life and main psychological problems encountered in young adults with an ICD. We studied 45 subjects aged 14-29 years (mean 21.2+/-4.3). ICDs were used in primary prevention in 22 patients, and in secondary prevention in 23 patients. Time elapsed from implantation ranged from 5 months to 11 years (4.3+/-2.7 years). Since the problems affecting this group were rather specific, the patients' quality of life was assessed with a special questionnaire addressing important issues and problems associated with living with an ICD. ICD discharges were observed in 67.4% of patients (primary prevention - 45.5%, secondary prevention - 82.6%), multiple shocks in 47.2%, and phantom shocks in 21.4%. Anxiety associated with an ICD discharge was reported by 84.4% of patients. In order to prevent ICD discharges, 53.3% of patients decreased their activity. Problems with memory were observed in 42.2% of patients, with concentration in 47.6%, and with sleep in 42.2%. Almost half of those over 18 years of age were active drivers. None of the subjects experienced an ICD discharge during sexual intercourse. None of the men reported any sexual problems, while seven (41.2%) women did. Almost a quarter of the patients claimed to have had complications after the implantation. Young adult patients generally were compliant to have their ICD checked and accepted their limitations and disease. Fewer people assessed their health status as bad. Some patients in the group studied found it extremely difficult to accept their disease and/or ICD and to adapt to the situation. As many as nine patients believed the ICD implantation had been unnecessary, seven did not accept the ICD, three

  5. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    M.T. Hoogwegt (Madelein); N. Kupper (Nina); D.A.M.J. Theuns (Dominic); L.J.L.M. Jordaens (Luc); S.S. Pedersen (Susanne)

    2012-01-01

    textabstractBeta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress.

  6. Comorbidity burden is associated with poor psychological well-being and physical health status in patients with an implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    Hoogwegt, M.T.; Kupper, N.; Jordaens, L.; Pedersen, S.S.; Theuns, D.A.M.J.

    2013-01-01

    Aims Comorbidity burden has been linked to survival in patients with an implantable cardioverter-defibrillator (ICD), but no study has examined the influence on psychological well-being and health status. We examined the relationship between comorbidity burden and anxiety, depression, and health

  7. Comorbidity burden is associated with poor psychological well-being and physical health status in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Jordaens, Luc

    2013-01-01

    Comorbidity burden has been linked to survival in patients with an implantable cardioverter-defibrillator (ICD), but no study has examined the influence on psychological well-being and health status. We examined the relationship between comorbidity burden and anxiety, depression, and health status...

  8. Risk of pacemaker or implantable cardioverter defibrillator after radiotherapy for early-stage breast cancer in Denmark, 1982-2005

    DEFF Research Database (Denmark)

    Rehammar, Jens Christian; Johansen, Jens Brock; Jensen, Maj-Britt

    2017-01-01

    BACKGROUND AND PURPOSE: To examine the risk of cardiac conduction abnormalities or severe ventricular arrhythmias requiring implantation of a cardiac implantable electronic device (CIED), either a pacemaker or an implantable cardioverter-defibrillator, subsequent to breast cancer (BC) radiotherapy...... (RT). MATERIAL AND METHODS: All women treated for early-stage BC in Denmark from 1982 to 2005 were identified from the Danish Breast Cancer Cooperative Group. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on CIED implants subsequent to RT. Standardized incidence...... ratios (SIR) of CIED implantation were estimated for women receiving RT and compared to women not receiving RT for BC. Uni- and multivariate Poisson regression models were used to estimate incidence rate ratios (IRR) among irradiated women compared to non-irradiated. RESULTS: Of 44,423 BC patients, 179...

  9. Clinical predictors and prognostic significance of electrical storm in patients with implantable cardioverter defibrillators.

    Science.gov (United States)

    Brigadeau, François; Kouakam, Claude; Klug, Didier; Marquié, Christelle; Duhamel, Alain; Mizon-Gérard, Frédérique; Lacroix, Dominique; Kacet, Salem

    2006-03-01

    Insufficient data exists regarding predictors of electrical storms (ES) and clinical outcome in patients treated with an implantable cardioverter defibrillator (ICD). The purpose of this study was to delineate a subgroup of patients likely to experience ES and to determine the impact of ES on mortality in ICD recipients. Baseline characteristics of 307 ICD-treated patients were retrospectively analysed. ES was defined as two or more ventricular tachyarrhythmias within 24 h leading to an immediate electrical therapy (antitachycardia pacing and/or shock), separated by a period of sinus rhythm. Clinical characteristics and survival of 123 patients experiencing a total of 294 episodes of ES (median 2 ES/patient, range 1-9), were compared with those of 184 ES-free patients during a median follow-up of 826 days (inter-quartile 1141 days). Median actuarial duration for the first ES occurrence after ICD implant was 1417 days [95% confidence interval (CI) 1061-2363] with a median follow-up of 816 days (7-4642 days) in ES-free patients. Univariate analysis identified older age, depressed left ventricular ejection fraction (LVEF), ventricular tachycardia (VT) as index arrhythmia, chronic renal failure and absence of lipid-lowering drugs as variables significantly associated with an increased risk of ES. Multivariable Cox analysis confirmed an independent predictive value for chronic renal failure [hazard ratio (HR) 1.54, 95% CI 0.95-2.51, P=0.052], VT (HR 2.20, 95% CI 1.44-3.37, P=0.0003), and LVEF (HR 0.98, 95% CI 0.97-0.99, P=0.027). In contrast, diabetics (HR 0.49, 95% CI 0.27-0.90, P=0.022) were less affected by ES. There was no difference in survival between both groups. ES is frequent but does not increase mortality in ICD's recipients. Patients with severe systolic dysfunction, chronic renal failure and VT as initial arrhythmia are likely to experience ES. Diabetics are less affected by ES.

  10. Comparison of clinical benefits and outcome in patients with programmable and nonprogrammable implantable cardioverter defibrillators.

    Science.gov (United States)

    Mehta, D; Saksena, S; Krol, R B; Makhija, V

    1992-09-01

    Technological advances in implantable cardioverter defibrillators (ICDs) have provided a variety of programmable parameters and antitachycardia therapies whose utility and impact on clinical outcome is presently unknown. ICDs have capabilities for cardioversion defibrillation alone (first generation ICDs), or in conjunction with demand ventricular pacing (second generation ICDs), or with demand pacing and antitachycardia pacing (third generation ICDs). We examined the pattern of antitachycardia therapy use and long-term survival in 110 patients with sustained ventricular tachycardia (VT) or ventricular fibrillation (VF). Group I included 62 patients with nonprogrammable first generation ICDs that delivered committed shock therapy after ventricular tachyarrhythmia detection based on electrogram rate and/or morphology was satisfied. Group II included 48 patients with multiprogrammable ICDs (including second and third generation ICDs) that had programmable tachyarrhythmia detection based on rate and tachycardia confirmation prior to delivery of electrical treatment with either programmable shocks and/or, as in the third generation ICDs, antitachycardia pacing. Incidence and patterns of antitachycardia therapy use and long-term survival were compared in the two groups. The incidence of appropriate shocks in patients who completed 1 year of follow-up was significantly greater in group I (30 of 43 patients = 70% vs 11 of 26 patients = 42%; P less than 0.05). In the total follow-up period, a significantly larger proportion of group I patients as compared to group II patients used the shock therapies (46 of 62 patients = 74% vs 25 of 48 patients = 52%; P less than 0.01), with the majority doing so within the first year of implantation (96% and 92%, respectively). Although the frequency of antitachycardia therapy activation was similar, the number of shocks delivered per patient was lower in group II, particularly in the initial 3 months of follow-up (P = 0.06). No clinical

  11. Optimism as predictor of patient-reported outcomes in patients with an implantable cardioverter defibrillator (data from the WEBCARE study)

    DEFF Research Database (Denmark)

    Habibović, M; Broers, E; Heumen, D

    2018-01-01

    OBJECTIVE: The implantable cardioverter defibrillator (ICD) is the treatment of choice for prevention of sudden cardiac death. However, a subgroup of ICD patients experiences psychological adjustment problems post implant. To date, positive psychological constructs (e.g. optimism) have been...... understudied in this population. Hence, we examined the association between optimism and anxiety, depression, and health status at 12-months post implant. METHODS: Patients (N=171) enrolled in the WEB-based distress management study for ICD patients were included in the analyses. Optimism and pessimism (LOT......), and Type D personality (DS14) were administered at baseline, while anxiety (GAD-7), depression (PHQ-9), and health status (SF-12) were assessed at 12-months. RESULTS: The mean age was 59.6±10.06 with 81% being male. After controlling for demographic, personality, and clinical variables, baseline optimism...

  12. In vitro assessment of the immunity of implantable cardioverter-defibrillators to magnetic fields of 50/60 Hz

    International Nuclear Information System (INIS)

    Katrib, J; Nadi, M; Kourtiche, D; Schmitt, P; Roth, P; Magne, I; Souques, M

    2013-01-01

    Public concern for the compatibility of electromagnetic (EM) sources with active implantable medical devices (AIMD) has prompted the development of new systems that can perform accurate exposure studies. EM field interference with active cardiac implants (e.g. implantable cardioverter-defibrillators (ICDs)) can be critical. This paper describes a magnetic field (MF) exposure system and the method developed for testing the immunity of ICD to continuous-wave MFs. The MFs were created by Helmholtz coils, housed in a Faraday cage. The coils were able to produce highly uniform MFs up to 4000 µT at 50 Hz and 3900 µT at 60 Hz, within the test space. Four ICDs were tested. No dysfunctions were found in the generated MFs. These results confirm that the tested ICDs were immune to low frequency MFs. (paper)

  13. Monitoring treatment expectations in patients with an implantable cardioverter-defibrillator using the EXPECT-ICD scale

    DEFF Research Database (Denmark)

    Habibovic, Mirela; Pedersen, Susanne S.; van den Broek, Krista C

    2014-01-01

    AIMS: Patient treatment expectations may affect cardiac outcomes; however, till date, no validated instruments have been developed to monitor treatment expectations in patients with an implantable cardioverter-defibrillator (ICD). This study evaluates the predictive value of the newly developed 10...... with a two-factor model involving both negative (α = 0.84) and positive expectations (α = 0.77) with a score range of 0-20 for each factor. Negative treatment expectations were associated with higher levels of anxiety (β = 0.443; P ...-item EXPECtations Towards ICD therapy (EXPECT-ICD) in relation to anxiety, depression, and ICD related concerns 3 months post-implant.METHODS AND RESULTS: Consecutive implanted ICD patients were included as part of the WEB-based distress management programme for ICD patients (WEBCARE) trial from six...

  14. Electromagnetic interference from welding and motors on implantable cardioverter-defibrillators as tested in the electrically hostile work site.

    Science.gov (United States)

    Fetter, J G; Benditt, D G; Stanton, M S

    1996-08-01

    This study was designed to determine the susceptibility of an implanted cardioverter-defibrillator to electromagnetic interference in an electrically hostile work site environment, with the ultimate goal of allowing the patient to return to work. Normal operation of an implanted cardioverter-defibrillator depends on reliable sensing of the heart's electrical activity. Consequently, there is concern that external electromagnetic interference from external sources in the work place, especially welding equipment or motor-generator systems, may be sensed and produce inappropriate shocks or abnormal reed switch operation, temporarily suspending detection of ventricular tachycardia or ventricular fibrillation. The effects of electromagnetic interference on the operation of one type of implantable cardioverter-defibrillator (Medtronic models 7217 and 7219) was measured by using internal event counter monitoring in 10 patients operating arc welders at up to 900 A or working near 200-hp motors and 1 patient close to a locomotive starter drawing up to 400 A. The electromagnetic interference produced two sources of potential interference on the sensing circuit or reed switch operation, respectively: 1) electrical fields with measured frequencies up to 50 MHz produced by the high currents during welding electrode activation, and 2) magnetic fields produced by the current in the welding electrode and cable. The defibrillator sensitivity was programmed to the highest (most sensitive) value: 0.15 mV (model 7219) or 0.3 mV (model 7217). The ventricular tachycardia and ventricular fibrillation therapies were temporarily turned off but the detection circuits left on. None of the implanted defibrillators tested were affected by oversensing of the electric field as verified by telemetry from the detection circuits. The magnetic field from 225-A welding current produced a flux density of 1.2 G; this density was not adequate to close the reed switch, which requires approximately 10 G

  15. Psychometric analysis of the Patient Health Questionnaire in Danish patients with an implantable cardioverter defibrillator (The DEFIB-WOMEN study)

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Mathiasen, Kim; Christensen, Karl Bang

    2016-01-01

    OBJECTIVE: To assess the psychometric properties of the Patient Health Questionnaire (PHQ-9), a measure of depressive symptoms, in a large Danish national cohort of patients with heart disease, implanted with an implantable cardioverter defibrillator (ICD), using item response theory. METHODS: A ...... of nine items for the partial credit model and five of nine items for the generalized partial credit model, indicating that respondents have difficulty discriminating between response options. When collapsing response options 2 and 3, the rescored PHQ-9 had a better fit to both models....... Three items did not fit the partial credit model, but the generalized partial credit model could be fitted to the full item set. CONCLUSION: The unidimensionality and reliability of the Danish version of the PHQ-9 were confirmed. However, the associated consequences of the number of response options (3...

  16. Automatic remote monitoring utilizing daily transmissions: transmission reliability and implantable cardioverter defibrillator battery longevity in the TRUST trial.

    Science.gov (United States)

    Varma, Niraj; Love, Charles J; Schweikert, Robert; Moll, Philip; Michalski, Justin; Epstein, Andrew E

    2018-04-01

    Benefits of automatic remote home monitoring (HM) among implantable cardioverter defibrillator (ICD) patients may require high transmission frequency. However, transmission reliability and effects on battery longevity remain uncertain. We hypothesized that HM would have high transmission success permitting punctual guideline based follow-up, and improve battery longevity. This was tested in the prospective randomized TRUST trial. Implantable cardioverter defibrillator patients were randomized post-implant 2:1 to HM (n = 908) (transmit daily) or to Conventional in-person monitoring [conventional management (CM), n = 431 (HM disabled)]. In both groups, five evaluations were scheduled every 3 months for 15 months. Home Monitoring technology performance was assessed by transmissions received vs. total possible, and number of scheduled HM checks failing because of missed transmissions. Battery longevity was compared in HM vs. CM at 15 months, and again in HM 3 years post-implant using continuously transmitted data. Transmission success per patient was 91% (median follow-up of 434 days). Overall, daily HM transmissions were received in 315 795 of a potential 363 450 days (87%). Only 55/3759 (1.46%) of unsuccessful scheduled evaluations in HM were attributed to transmission loss. Shock frequency and pacing percentage were similar in HM vs. CM. Fifteen month battery longevity was 12% greater in HM (93.2 ± 8.8% vs. 83.5 ± 6.0% CM, P battery longevity was 50.9 ± 9.1% (median 52%) at 36 months. Automatic remote HM demonstrated robust transmission reliability. Daily transmission load may be sustained without reducing battery longevity. Home Monitoring conserves battery longevity and tracks long term device performance. ClinicalTrials.gov; NCT00336284.

  17. Catheter ablation for the treatment of electrical storm in patients with implantable cardioverter-defibrillators: short- and long-term outcomes in a prospective single-center study.

    Science.gov (United States)

    Carbucicchio, Corrado; Santamaria, Matteo; Trevisi, Nicola; Maccabelli, Giuseppe; Giraldi, Francesco; Fassini, Gaetano; Riva, Stefania; Moltrasio, Massimo; Cireddu, Manuela; Veglia, Fabrizio; Della Bella, Paolo

    2008-01-29

    Electrical storm (ES) caused by recurrent episodes of ventricular tachycardia (VT) can cause sudden death in patients with implantable cardioverter-defibrillators and adversely affects prognosis in survivors. Catheter ablation has been proposed for treating ES, but its long-term effect in a large population has never been verified. Ninety-five consecutive patients with coronary artery disease (72 patients), idiopathic dilated cardiomyopathy (10 patients), and arrhythmogenic right ventricular dysplasia/cardiomyopathy (13 patients) undergoing catheter ablation for drug-refractory ES were prospectively evaluated. Short-term efficacy was defined by a complete protocol of programmed electric stimulation and by in-hospital outcome; long-term analysis addressed ES recurrence, cardiac mortality, and VT recurrence. Pleomorphic/nontolerated VTs required electroanatomic and noncontact mapping in 48 and 22 patients, respectively, and percutaneous cardiopulmonary support in 10 patients. An epicardial approach was used in 10 patients. After 1 to 3 procedures, induction of any clinical VT(s) by programmed electrical stimulation was prevented in 85 patients (89%). ES was acutely suppressed in all patients; a minimum period of 7 days with stable rhythm was required before hospital discharge. At a median follow-up of 22 months (range, 1 to 43 months), 87 patients (92%) were free of ES and 63 patients (66%) were free of VT recurrence. Eight of 10 patients with persistent inducibility of clinical VT(s) had ES recurrence; 4 of them died suddenly despite appropriate implantable cardioverter-defibrillator intervention. All together, 11 of 95 patients (12%) died of cardiac-related reasons. In the group of patients presenting with all clinical VTs acutely abolished, no ES recurrence was documented, and cardiac mortality was significantly lower compared with the group of patients showing > or = 1 clinical VT still inducible after catheter ablation. Advanced strategies of catheter ablation

  18. Standardized programming to reduce the burden of inappropriate therapies in implantable cardioverter defibrillators - Single centre follow up results

    Directory of Open Access Journals (Sweden)

    U. Boles

    2018-03-01

    Full Text Available Background: Current algorithms and device morphology templates have been proposed in current Implantable Cardioverter-Defibrillators (ICDs to minimize inappropriate therapies (ITS, but this has not been completely successful. Aim: Assess the impact of a deliberate strategy of using an atrial lead implant with standardized parameters; based on all current ICD discriminators and technologies, on the burden of ITS. Method: A retrospective single-centre analysis of 250 patients with either dual chamber (DR ICDs or biventricular ICDs (CRTDs over a (41.9 ± 27.3 month period was performed. The incidence of ITS on all ICD and CRTD patients was chronicled after the implementation of standardized programming. Results: 39 events of anti-tachycardial pacing (ATP and/or shocks were identified in 20 patients (8% incidence rate among patients. The total number of individual therapies was 120, of which 34% were inappropriate ATP, and 36% were inappropriate shocks. 11 patients of the 250 patients received ITS (4.4%. Of the 20 patients, four had ICDs for primary prevention and 16 for a secondary prevention. All the episodes in the primary indication group were inappropriate, while seven patients (43% of the secondary indication group experienced inappropriate therapies. Conclusions: The burden of ITS in the population of patients receiving ICDs was 4.4% in the presence of atrial leads. The proposed rationalized programming criteria seems an effective strategy to minimize the burden of inappropriate therapies and will require further validation. Keywords: Implantable cardioverter-defibrillator (ICDs, Inappropriate therapies, Standardized programming

  19. Implantable Cardioverter-Defibrillator Therapy in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy: Predictors of Appropriate Therapy, Outcomes, and Complications.

    Science.gov (United States)

    Orgeron, Gabriela M; James, Cynthia A; Te Riele, Anneline; Tichnell, Crystal; Murray, Brittney; Bhonsale, Aditya; Kamel, Ihab R; Zimmerman, Stephan L; Judge, Daniel P; Crosson, Jane; Tandri, Harikrishna; Calkins, Hugh

    2017-06-06

    Arrhythmogenic right ventricular dysplasia/cardiomyopathy is characterized by ventricular arrhythmias and sudden cardiac death. Once the diagnosis is established, risk stratification to determine whether implantable cardioverter-defibrillator (ICD) placement is warranted is critical. The cohort included 312 patients (163 men, age at presentation 33.6±13.9 years) with definite arrhythmogenic right ventricular dysplasia/cardiomyopathy who received an ICD. Over 8.8±7.33 years, 186 participants (60%) had appropriate ICD therapy and 58 (19%) had an intervention for ventricular fibrillation/flutter. Ventricular tachycardia at presentation (hazard ratio [HR]: 1.86; 95% confidence interval [CI], 1.38-2.49; P right ventricular dysplasia/cardiomyopathy. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  20. Thoracoscopic Left Cardiac Sympathetic Denervation for a Patient with Catecholaminergic Polymorphic Ventricular Tachycardia and Recurrent Implantable Cardioverter-Defibrillator Shocks

    Directory of Open Access Journals (Sweden)

    Woo-Sik Yu

    2015-06-01

    Full Text Available A patient presented with loss of consciousness and conversion. During an exercise test, catecholaminergic polymorphic ventricular tachycardia (CPVT resulted in cardiac arrest. He started taking medication (a beta-blocker and flecainide and an implantable cardioverter defibrillator (ICD was inserted, but the ventricular tachycardia did not resolve. Left cardiac sympathetic denervation (LCSD was then performed under general anesthesia, and the patient was discharged on the second postoperative day without complications. One month after the operation, no shock had been administered by the ICD, and an exercise stress test did not induce ventricular tachycardia. Although beta- blockers are the gold standard of therapy in patients with CPVT, thoracoscopic LCSD is safe and can be an effective alternative treatment option for patients with intractable CPVT.

  1. Determining the risks of magnetic resonance imaging at 1.5 tesla for patients with pacemakers and implantable cardioverter defibrillators.

    Science.gov (United States)

    Cohen, Jennifer D; Costa, Heather S; Russo, Robert J

    2012-12-01

    Conventional pacemaker and implantable cardioverter-defibrillator product labeling currently cautions against exposure to magnetic resonance imaging (MRI). However, there is a growing clinical need for MRI, without an acceptable alternative imaging modality in many patients with cardiac devices. The purpose of this study was to determine the risk of MRI at 1.5 T for patients with cardiac devices by measuring the frequency of device failures and clinically relevant device parameter changes. Data from a single-center retrospective review of 109 patients with pacemakers and implantable cardioverter-defibrillators (the MRI group) who underwent 125 clinically indicated MRI studies were compared to data from a prospective cohort of 50 patients with cardiac devices who did not undergo MRI (the control group). In the MRI group, there were no deaths, device failures requiring generator or lead replacement, induced arrhythmias, losses of capture, or electrical reset episodes. Decreases in battery voltage of ≥0.04 V occurred in 4%, pacing threshold increases of ≥0.5 V in 3%, and pacing lead impedance changes of ≥50 Ω in 6%. Although there were statistically significant differences between the MRI and control groups for the mean change in pacing lead impedance (-6.2 ± 23.9 vs 3.0 ± 22.1 Ω) and left ventricular pacing threshold (-0.1 ± 0.3 vs 0.1 ± 0.2 V), these differences were not clinically important. In conclusion, MRI in patients with cardiac devices resulted in no device or lead failures. A small number of clinically relevant changes in device parameter measurements were noted. However, these changes were similar to those in a control group of patients who did not undergo MRI. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Psychometric properties of HeartQoL, a core heart disease-specific health-related quality of life questionnaire, in Danish implantable cardioverter defibrillator recipients

    DEFF Research Database (Denmark)

    Zangger, Graziella; Zwisler, Ann-Dorthe; Kikkenborg Berg, Selina

    2017-01-01

    Background Patient-reported health-related quality of life is increasingly used as an outcome measure in clinical trials and as a performance measure to evaluate quality of care. The objective of this study was to assess the psychometric properties of the Danish HeartQoL questionnaire, a core heart...... disease-specific health-related quality of life questionnaire, in implantable cardioverter defibrillator recipients. Design This study involved cross-sectional and test-retest study designs. Method Implantable cardioverter defibrillator recipients in the cross-sectional study completed the Heart......QoL, the Short-Form 36 Health Survey, and the Hospital Anxiety and Depression Scale. The HeartQoL structure, construct-related validity (convergent and discriminative) and reliability (internal consistency) were assessed. HeartQoL reproducibility (test-retest) was assessed in an independent sample of implantable...

  3. Impact of programming strategies aimed at reducing nonessential implantable cardioverter defibrillator therapies on mortality: a systematic review and meta-analysis.

    Science.gov (United States)

    Tan, Vern Hsen; Wilton, Stephen B; Kuriachan, Vikas; Sumner, Glen L; Exner, Derek V

    2014-02-01

    Patients who receive implantable cardioverter defibrillator therapies are at higher risk of death versus those who do not. Programmed settings to reduce nonessential implantable cardioverter defibrillator therapies (therapy reduction programming) have been developed but may have adverse effects. This systematic review and meta-analysis assessed the relationship between therapy reduction programming with the risks of death from any cause, implantable cardioverter defibrillator shocks, and syncope. MEDLINE, EMBASE, and clinicaltrials.gov databases were searched to identify relevant studies. Those that followed patients for ≥6 months and reported mortality were included. Six met the inclusion criteria; 4 randomized (Comparison of Empiric to Physician-Tailored Programming of ICDs [EMPIRIC], Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy [MADIT-RIT], Avoid Delivering Therapies for Non-sustained Arrhythmias in ICD Patients III [ADVANCE III], and Programming Implantable Cardioverter-Defibrillators in Patients with Primary Prevention Indication to Prolong Time to First Shock [PROVIDE]) and 2 prospective studies (Role of Long Detection Window Programming in Patients With Left Ventricular Dysfunction, Non-ischemic Etiology in Primary Prevention Treated with a Biventricular ICD [RELEVANT] and Primary Prevention Parameters Evaluation [PREPARE]). These 6 studies included 7687 (3598 conventional and 4089 therapy reduction programming) patients. Most (77%) participants were men, had a history of ischemic heart disease (56%), and were prescribed β-blockers (84%). Therapy reduction programming was associated with a 30% relative reduction in mortality (95% confidence interval, 16%-41%; Pprogramming (P=0.5). Therapy reduction programming results in a large, significant, and consistent reduction in mortality, with no apparent increase in the risk of syncope.

  4. Management of radiation oncology patients with implanted cardiac pacemakers or implant able cardioverter defibrilators; Tratamiento de pacientes en radioterapia con marcapasos o desfibriladores automaticos implantables

    Energy Technology Data Exchange (ETDEWEB)

    Martin Martin, G.

    2012-07-01

    The increase in life expectancy along with the technological development in the last decades has resulted in an increase in the number of patients requiring pacemaker implants or implantable cardioverter defibrillators worldwide. An increase in the number of patients with implanted cardiac devices in radiotherapy is also expected due to the risk factors in common between heart disease and cancer. In 1994 the American Association of Physicists in Medicine (AAPM) released a report about the management of radiation oncology patients with implanted cardiac pacemakers. The addition of new technologies, both in radiotherapy units and in the manufacturing process of heart devices, has shown the need for an updated protocol for the management of these patients. In this work, the most important articles published after the report of the AAPM have been compiled, in order to analyze the effects not previously studied such as dose rate, scattered radiation, electromagnetic interference or random failures produced by neutrons and protons. Additionally, the latest recommendations given by the manufacturers have been analyzed and, finally, some indications are given as an updated guide for the management of radiation oncology patients with pacemakers or cardioverter defibrillators implanted. (Author)

  5. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J

    2012-01-01

    Beta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress. We...... investigated the association between beta-blocker therapy, including type and dosage, and symptoms of anxiety and depression in a consecutive cohort of patients receiving an ICD....

  6. Unmappable ventricular tachycardia after an old myocardial infarction. Long-term results of substrate modification in patients with an implantable cardioverter defibrillator

    OpenAIRE

    Alzand, B. S. N.; Timmermans, C. C. M. M.; Wellens, H. J. J.; Dennert, R.; Philippens, S. A. M.; Portegijs, P. J. M.; Rodriguez, LM.

    2011-01-01

    Purpose The frequent occurrence of ventricular tachycardia can create a serious problem in patients with an implantable cardioverter defibrillator. We assessed the long-term efficacy of catheter-based substrate modification using the voltage mapping technique of infarct-related ventricular tachycardia and recurrent device therapy. Methods The study population consisted of 27 consecutive patients (age 68 ± 8 years, 25 men, mean left ventricular ejection fraction 31 ± 9%) with an old myocardial...

  7. Implantable cardioverter-defibrillators improve survival after coronary artery bypass grafting in patients with severely impaired left ventricular function

    Directory of Open Access Journals (Sweden)

    Pasque Michael K

    2007-01-01

    Full Text Available Abstract Objective Patients with severe left ventricular (LV dysfunction have a poor long term survival despite complete surgical revascularization. Recent data suggests that the use of Implantable Cardioverter-Defibrillator (ICD improves survival in patients with severe LV dysfunction. We compared the survival impact of ICD implantation in patients with severe LV dysfunction who underwent CABG. Methods Between January 1996 and August 2004, 305 patients with LV ejection fraction (EF ≤25% had CABG surgery at our institution. Demographics of patients who had received an ICD (ICD+ in the post -operative period was compared to those without ICD (ICD-. Survival was evaluated by the Kaplan-Meier method. Results Of the entire group, 35 (11.5% patients received an ICD with a median of 2 (+/-2 years after CABG. Indication for ICD implantation was clinical evidence of non sustained ventricular tachycardia (NSVT. There were no differences between the 2 groups with respect to age, gender, NYHA classification, number of bypasses, or other co-morbidities. Survival at 1, 3 and 5 years was 88%, 79%, and 67% for the ICD- group compared to 94%, 89% and 83% for the ICD+ group, respectively (figure, p Conclusion Implantation of ICD after CABG confers improved short and long term survival benefit to patients with severe LV dysfunction. Prophylactic ICD implantation in the setting of severe LV dysfunction and CABG surgery should be considered.

  8. Classic conditioning and dysfunctional cognitions in patients with panic disorder and agoraphobia treated with an implantable cardioverter/defibrillator.

    Science.gov (United States)

    Godemann, F; Ahrens, B; Behrens, S; Berthold, R; Gandor, C; Lampe, F; Linden, M

    2001-01-01

    A model for the development of anxiety disorders (panic disorder with or without agoraphobia) is needed. Patients with an implantable cardioverter/defibrillator (ICD) are exposed to repeated electric shocks. If the theory of anxiety development by aversive classic conditioning processes is valid, these repeated shocks should lead to an increased risk of anxiety disorders. To study this hypothesis, we retrospectively studied 72 patients after implantation of an automatic ICD. Patients were assessed with the semistructured Diagnostic Interview of Psychiatric Disease 1 to 6 years after implantation of an automatic ICD. Panic disorder and/or agoraphobia was diagnosed in patients who fulfilled all DSM-III-R criteria for those conditions. Anxiety disorder developed in 15.9% of patients after ICD implantation. This was significantly related to the frequency of repeated defibrillation (shocks) to stop malignant ventricular arrhythmias. Dysfunctional cognitions are an additional vulnerability factor. The data support both the conditioning hypothesis and the cognitive model of anxiety development. These findings suggest that ICD patients are an appropriate risk population for a prospective study of the development of anxiety disorders.

  9. Sex is associated with differences in individual trajectories of change in social health after implantable cardioverter-defibrillator.

    Science.gov (United States)

    Lauck, Sandra B; Sawatzky, Richard; Johnson, Joy L; Humphries, Karin; Bennett, Matthew T; Chakrabarti, Santabhanu; Kerr, Charles R; Tung, Stanley; Yeung-Lai-Wah, John A; Ratner, Pamela A

    2015-03-01

    Social health is a dimension of quality of life, and refers to people's involvement in, and satisfaction with social roles, responsibilities, and activities. The implantable cardioverter-defibrillator is associated with changes in overall quality of life, but little is known about sex differences in individual trajectories of change in social health. We prospectively measured changes in 3 subscales of the SF-36v2 generic health questionnaire (role physical, role emotional, and social functioning), 2 Patient-Reported Outcomes Measurement Information System short forms (satisfaction with participation in social roles and satisfaction with participation in discretionary social activities), and the Florida Patient Acceptance Survey before and at 1, 2, and 6 months after implantation. Individual growth models of temporal change were estimated. The scores of the 6 indicators improved with time. The unconditional model demonstrated significant (fixed effects: Pchange in the scores of 3 of the 6 measures. Although men's mean scores exceeded women's mean scores on all indicators at baseline (range of relative mean difference: 11.0% to 17.8%), the rate of women's change resulted in a reversal in relative standing at 6 months after implantation, with the mean scores of women exceeding the men's by 4.5% to 5.6%. Men and women differed in their trajectories of change in social health, both in terms of their starting points (ie, baseline scores) and their rates of change. © 2015 American Heart Association, Inc.

  10. Failed anti-tachycardia pacing can be used to differentiate atrial arrhythmias from ventricular tachycardia in implantable cardioverter-defibrillators.

    Science.gov (United States)

    Michael, Kevin A; Enriquez, Andres; Baranchuk, Adrian; Haley, Charlotte; Caldwell, Jane; Simpson, Christopher S; Abdollah, Hoshiar; Redfearn, Damian P

    2015-01-01

    Atrial fibrillation/tachycardia (AF/AT) may result in inappropriate therapies in implantable cardioverter-defibrillators (ICDs). The post-pacing interval (PPI) and tachycardia cycle length difference (PPI - TCL) has been previously demonstrated to indicate the proximity of the pacing site to a tachycardia origin. We postulated that the PPI and PPI - TCL would be greater in AT/AF vs. ventricular tachycardia (VT) after episodes of failed anti-tachycardia pacing (ATP). This was a single-centre, retrospective study evaluating consecutive patients implanted with dual (DR)/biventricular (BIV) ICDs. Stored electrograms were used to determine whether the ATP captured the arrhythmia and the arrhythmia did not present with primary or secondary termination. Measurements were done using manual calipers. A total of 155 patients were included. There were 79 BIV and 76 DR devices. In total, 39 episodes were identified in 20 patients over a 23-month follow-up period. A total of 76 sequences of ATP (burst/ramp) were delivered, 28 (37%) of them inappropriate. Fifty-one events (18 AT/AF and 33 VT) were compared. The mean PPI was 693 ± 96 vs. 512 ± 88 ms (P failed ATP differs significantly between AF/AT and VT and are therefore useful indices to discriminate between supraventricular tachycardia and VT in ICDs. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  11. Implantable cardioverter defibrillator therapy in pediatric and congenital heart disease patients: a single tertiary center experience in Korea

    Directory of Open Access Journals (Sweden)

    Bo Kyung Jin

    2013-03-01

    Full Text Available Purpose: The use of implantable cardioverter defibrillators (ICDs to prevent sudden cardiac death is increasing in children and adolescents. This study investigated the use of ICDs in children with congenital heart disease. Methods: This retrospective study was conducted on the clinical characteristics and effectiveness of ICD implantation at the department of pediatrics of a single tertiary center between 2007 and 2011. Results: Fifteen patients underwent ICD implantation. Their mean age at the time of implantation was 14.5±5.4 years (range, 2 to 22 years. The follow-up duration was 28.9±20.4 months. The cause of ICD implantation was cardiac arrest in 7, sustained ventricular tachycardia in 6, and syncope in 2 patients. The underlying disorders were as follows: ionic channelopathy in 6 patients (long QT type 3 in 4, catecholaminergic polymorphic ventricular tachycardia [CPVT] in 1, and J wave syndrome in 1, cardiomyopathy in 5 patients, and postoperative congenital heart disease in 4 patients. ICD coils were implanted in the pericardial space in 2 children (ages 2 and 6 years. Five patients received appropriate ICD shock therapy, and 2 patients received inappropriate shocks due to supraventricular tachycardia.During follow-up, 2 patients required lead dysfunction-related revision. One patient with CPVT suffered from an ICD storm that was resolved using sympathetic denervation surgery. Conclusion: The overall ICD outcome was acceptable in most pediatric patients. Early diagnosis and timely ICD implantation are recommended for preventing sudden death in high-risk children and patients with congenital heart disease.

  12. Safety of sports participation in patients with implantable cardioverter defibrillators: a survey of heart rhythm society members.

    Science.gov (United States)

    Lampert, Rachel; Cannom, David; Olshansky, Brian

    2006-01-01

    Safety of Sports for ICD Patients. The safety of sports participation for patients with implantable cardioverter defibrillators (ICDs) is unknown, and recommendations among physicians may vary widely. The purposes of this study were to determine current practice among patients with ICDs and their physicians regarding sports participation, and to determine how many physicians have cared for patients who have sustained adverse events during sports participation. A survey was mailed to all 1,687 U.S. physician members of the Heart Rhythm Society. Among 614 respondent physicians, recommendations varied widely. Only 10% recommended avoidance of all sports more vigorous than golf. Seventy-six percent recommended avoidance of contact, and 45% recommend avoidance of competitive sports. Most (71%) based restrictions on patients' underlying heart disease. Regardless of recommendations, most physicians (71%) reported caring for patients who participated in sports, including many citing vigorous, competitive sports, most commonly cited were basketball, running, and skiing. ICD shocks during sports were common, cited by 40% of physicians. However, few adverse consequences were reported. One percent of physicians reported known injury to patient (all but 3 minor); 5%, injury to the ICD system, and weightlifting and golf. Physician recommendations for sports participation for patients with ICDs varies widely. Many patients with ICDs do participate in vigorous and even competitive sports. While shocks were common, significant adverse events were rare.

  13. Association of air pollution with increased incidence of ventricular tachyarrhythmias recorded by implantable cardioverter defibrillators: Vulnerable patients to air pollution.

    Science.gov (United States)

    Kim, In-Soo; Sohn, Jungwoo; Lee, Seung-Jun; Park, Jin-Kyu; Uhm, Jae-Sun; Pak, Hui-Nam; Lee, Moon-Hyoung; Kim, Changsoo; Joung, Boyoung

    2017-08-01

    This study investigated the acute effects of exposure to air pollution on ventricular tachyarrhythmias (VTAs) in an East Asian population. The association between air pollution and VTA has not yet been studied in an East Asian country affected by the Asian dust phenomenon, which worsens air quality. The study cohort consisted of 160patients with implantable cardioverter defibrillator (ICD) devices in the Seoul metropolitan area who were followed for 5.5±3.8years. We used ICD records of VTAs and matched these with hourly measurements of air pollutant concentrations and meteorological data. Fine particle mass and gaseous air pollution plus temperature and relative humidity were measured hourly during the study period. During the study period, 1064 VTA events including 204 instances of ventricular fibrillation (VF) were observed. We found a statistically significant association between overall VTA events and SO 2 (lag 24h; OR 1.49, 95%CI 1.16-1.92, p=0.002), PM 10 (lag 2h; OR 2.56, 95%CI 2.03-3.23, pair pollution and VTA were observed in a metropolitan area of an East Asian country. Exposures to SO 2 , PM 10 , NO 2 , and CO were significantly associated with VTAs in ICD patients with SHD. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Ventricular tachyarrhythmias and mortality in patients with an implantable cardioverter defibrillator: impact of depression in the MIDAS cohort.

    Science.gov (United States)

    Mastenbroek, Mirjam H; Versteeg, Henneke; Jordaens, Luc; Theuns, Dominic A M J; Pedersen, Susanne S

    2014-01-01

    We examined whether depression is independently associated with implantable cardioverter defibrillator (ICD) therapy for ventricular tachyarrhythmias and mortality. A cohort of 430 consecutive patients with a first-time ICD (79% men; mean [standard deviation] age = 57.8 [12.1] years) completed the Hospital Anxiety and Depression Scale 1 day before implantation. During follow-up, the ICD was interrogated at 3-month intervals. Cox proportional hazard regression analyses were used to examine the impact of depression on time to first appropriate ICD therapy and all-cause mortality during a median follow-up period of 3.8 years. Of all patients, 108 (25.1%) were depressed. Depression was not associated with time to first appropriate ICD therapy (unadjusted hazard ratio [HR] = 1.07, 95% confidence interval [CI] = 0.73-1.56). However, depression was associated with an increased risk for all-cause mortality (unadjusted HR = 2.18, 95% CI = 1.36-3.49). Depression remained independently associated with all-cause mortality (HR = 1.94, 95% CI = 1.06-3.54, p = .031), after adjusting for demographic and clinical characteristics. Patients who remained depressed during the first 3 months after implantation were at greatest risk for dying (HR = 2.88, 95% CI = 1.29-6.45, p = .010). The current study showed that depression at the time of implant is not associated with time to first appropriate ICD therapy but almost doubled the risk for all-cause mortality in patients with an ICD. Patients with persistent depression during the first 3 months after implantation face the greatest risk of dying. Current evidence indicates that multifactorial interventions are likely to be the most successful in terms of reducing distress. Whether this translates into enhanced survival has yet to be determined.

  15. Gender differences in anxiety and concerns about the cardioverter defibrillator

    DEFF Research Database (Denmark)

    Spindler, Helle; Johansen, Jens B; Andersen, Kirsten Krogh

    2009-01-01

    Little is known about gender differences in the response to implantable cardioverter defibrillator (ICD) therapy. We compared female and male ICD patients on anxiety, depression, health-related quality of life (HRQL), ICD concerns, and ICD acceptance.......Little is known about gender differences in the response to implantable cardioverter defibrillator (ICD) therapy. We compared female and male ICD patients on anxiety, depression, health-related quality of life (HRQL), ICD concerns, and ICD acceptance....

  16. Use of implantable cardioverter defibrillators after out-of-hospital cardiac arrest: a prospective follow-up study

    Science.gov (United States)

    Parkash, Ratika; Tang, Anthony; Wells, George; Blackburn, Josée; Stiell, Ian; Simpson, Christopher; Dorian, Paul; Yee, Raymond; Cameron, Doug; Connolly, Stuart; Birnie, David; Nichol, Graham

    2004-01-01

    Background Survivors of out-of-hospital cardiac arrest are at high risk of recurrent arrests, many of which could be prevented with implantable cardioverter defibrillators (ICDs). We sought to determine the ICD insertion rate among survivors of out-of-hospital cardiac arrest and to determine factors associated with ICD implantation. Methods The Ontario Prehospital Advanced Life Support (OPALS) study is a prospective, multiphase, before–after study assessing the effectiveness of prehospital interventions for people experiencing cardiac arrest, trauma or respiratory arrest in 19 Ontario communities. We linked OPALS data describing survivors of cardiac arrest with data from all defibrillator implantation centres in Ontario. Results From January 1997 to April 2002, 454 patients in the OPALS study survived to hospital discharge after experiencing an out-of-hospital cardiac arrest. The mean age was 65 (standard deviation 14) years, 122 (26.9%) were women, 398 (87.7%) had a witnessed arrest, 372 (81.9%) had an initial rhythm of ventricular tachycardia or ventricular fibrillation (VT/VF), and 76 (16.7%) had asystole or another arrhythmia. The median cerebral performance category at discharge (range 1–5, 1 = normal) was 1. Only 58 (12.8%) of the 454 patients received an ICD. Patients with an initial rhythm of VT/VF were more likely than those with an initial rhythm of asystole or another rhythm to undergo device insertion (adjusted odds ratio [OR] 9.63, 95% confidence interval [CI] 1.31–71.50). Similarly, patients with a normal cerebral performance score were more likely than those with abnormal scores to undergo ICD insertion (adjusted OR 12.52, 95% CI 1.74–92.12). Interpretation A minority of patients who survived cardiac arrest underwent ICD insertion. It is unclear whether this low usage rate reflects referral bias, selection bias by electrophysiologists, supply constraint or patient preference. PMID:15505267

  17. Safety of implantable pacemakers and cardioverter defibrillators in the magnetic field of a novel remote magnetic navigation system.

    Science.gov (United States)

    Jilek, Clemens; Tzeis, Stylianos; Reents, Tilko; Estner, Heidi-Luise; Fichtner, Stephanie; Ammar, Sonia; Wu, Jinjin; Hessling, Gabriele; Deisenhofer, Isabel; Kolb, Christof

    2010-10-01

    Electromagnetic interference with pacemaker and implantable cardioverter defibrillator (ICD) systems may cause temporary or permanent system malfunction of implanted devices. The aim of this study was to evaluate potential interference of a novel magnetic navigation system with implantable rhythm devices. A total of 121 devices (77 pacemakers, 44 ICDs) were exposed to an activated NIOBE II® Magnetic Navigation System (Stereotaxis, St. Louis, MO, USA) at the maximal magnetic field strength of 0.1 Tesla and evaluated in vitro with respect to changes in parameter settings of the device, changes of the battery status/detection of elective replacement indication, or alterations of data stored in the device. A total of 115 out of 121 (95%) devices were free of changes in parameter settings, battery status, and internally stored data after repeated exposition to the electromagnetic field of the remote magnetic navigation system. Interference with the magnetic navigation field was observed in 6 pacemakers, resulting in reprogramming to a power-on-reset mode with or without detection of the elective replacement indication in 5 devices and abnormal variance of battery status in one device. All pacemakers could be reprogrammed to the initial modes and the battery status proved to be normal some minutes after the pacemakers had been removed from the magnetic field. Interference of a remote magnetic navigation system (at maximal field strength) with pacemakers and ICDs not connected to leads with antitachycardic detection and therapies turned off is rare. Occurring functional abnormalities could be reprogrammed in our sample. An in vitro study will give information about interference of devices connected to leads. © 2010 Wiley Periodicals, Inc.

  18. Radiotherapy and risk of implantable cardioverter-defibrillator malfunctions: experimental data from direct exposure at increasing doses.

    Science.gov (United States)

    Zecchin, Massimo; Artico, Jessica; Morea, Gaetano; Severgnini, Mara; Bianco, Elisabetta; De Luca, Antonio; Fantasia, Anna Zorzin; Salvatore, Luca; Milan, Vittorino; Lucarelli, Matteo; Dissegna, Roberta; Cannatà, Antonio; Sinagra, Gianfranco

    2018-04-01

    During radiotherapy, in patients with implantable cardioverter-defibrillators (ICDs) malfunctions are considered more likely if doses more than 2 Gy reach the ICD site; however, most malfunctions occur with high-energy (>10 MV) radiations, and the risk is less defined using 6-MV linear accelerators. The purpose of the study is to experimentally evaluate the occurrence of malfunctions in ICDs radiated with a 6-MV linear accelerator at increasing photon doses. Thirty-two ICDs from all manufacturers (31 explanted and one demo) were evaluated; all devices with a sufficient battery charge underwent multiple radiations with a 6-MV photon beam reaching a cumulative dose at ICD site of 0.5, 1, 2, 3, 5 and 10 Gy and interrogated after every session. All antitachycardia therapies were left enabled; two ICDs were connected to a rhythm simulator (one simulating a complete atrioventricular block without ventricular activity) and visually monitored by external ECG and the ICD programmer during radiation. Thirteen ICDs were excluded before radiation because of battery depletion; after radiation up to the cumulative dose at the cardiac implantable electronic device site of 10 Gy, in the remaining 19 devices, programmation and battery charge remained unchanged and no switch to safety mode was observed; oversensing, pacing inhibition or inappropriate antitachycardia therapy were neither recorded nor visually observed during radiation. With a low-energy accelerator, neither malfunctions nor electromagnetic interferences were detected radiating the ICDs at doses usually reaching the ICD pocket during radiotherapy sessions. In this context, magnet application to avoid oversensing and inappropriate therapy seems, therefore, useless.

  19. Attitudes of older adults with serious competing health risks toward their implantable cardioverter-defibrillators: a pilot study.

    Science.gov (United States)

    Green, Ariel R; Boyd, Cynthia M; Rickard, John; Gomon, Robert; Leff, Bruce

    2015-12-23

    In elderly heart failure patients, the survival benefit of implantable cardioverter-defibrillators (ICDs) may be attenuated due to competing health risks, and the risk of adverse outcomes magnified. Our objective was to examine older adults' attitudes towards ICD implantation in the context of competing health risks, exploring the determinants of ICD decision-making among a group of patients who had faced the decision in the past. Telephone survey with a qualitative component. Patients were age ≥70 with single- or dual-chamber ICDs from a single academic cardiac device clinic. Health status was assessed with the Vulnerable Elders Survey (VES-13). Responses to open-ended questions were transcribed verbatim; an "editing analysis" approach was used to extract themes. Forty-four ICD recipients participated (mean age 77.5 years). Nineteen participants (43%) had VES-13 scores ≥3, indicating a 50% likelihood of death or functional decline within 2 years. Twenty-one participants (48%) had received prior ICD shocks. Forty participants (91%) said they would "definitely" choose to get an ICD again in their current health. By and large, patients revealed a strong desire to extend life, expressed complete confidence in the lifesaving capabilities of their ICDs, and did not describe consideration of competing health risks. In this pilot telephone survey with a qualitative component, nearly all older adults with ICDs would still choose to get an ICD despite high short-term risk of death or health deterioration. These findings suggest the need to partner more effectively with patients and families to decide how best to use medical technologies, particularly for older adults with competing risks.

  20. Prospective Randomized Evaluation of Implantable Cardioverter-Defibrillator Programming in Patients With a Left Ventricular Assist Device.

    Science.gov (United States)

    Richardson, Travis D; Hale, Leslie; Arteaga, Christopher; Xu, Meng; Keebler, Mary; Schlendorf, Kelly; Danter, Matthew; Shah, Ashish; Lindenfeld, JoAnn; Ellis, Christopher R

    2018-02-23

    Ventricular arrhythmias are common in patients with left ventricular assist devices (LVADs) but are often hemodynamically tolerated. Optimal implantable cardioverter defibrillator (ICD) tachy-programming strategies in patients with LVAD have not been determined. We sought to determine if an ultra-conservative ICD programming strategy in patients with LVAD affects ICD shocks. Adult patients with an existing ICD undergoing continuous flow LVAD implantation were randomized to standard ICD programming by their treating physician or an ultra-conservative ICD programming strategy utilizing maximal allowable intervals to detection in the ventricular fibrillation and ventricular tachycardia zones with use of ATP. Patients with cardiac resynchronization therapy (CRT) devices were also randomized to CRT ON or OFF. Patients were followed a minimum of 6 months. The primary outcome was time to first ICD shock. Among the 83 patients studied, we found no statistically significant difference in time to first ICD shock or total ICD shocks between groups. In the ultra-conservative group 16% of patients experienced at least one shock compared with 21% in the control group ( P =0.66). There was no difference in mortality, arrhythmic hospitalization, or hospitalization for heart failure. In the 41 patients with CRT ICDs fewer shocks were observed with CRT-ON but this was not statistically significant: 10% of patients with CRT-ON (n=21) versus 38% with CRT-OFF (n=20) received shocks ( P =0.08). An ultra-conservative programming strategy did not reduce ICD shocks. Programming restrictions on ventricular tachycardia and ventricular fibrillation zone therapy should be reconsidered for the LVAD population. The role of CRT in patients with LVAD warrants further investigation. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01977703. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  1. Is it safe to allow patients with implantable cardioverter-defibrillators to drive? Learnings from a single center experience.

    Science.gov (United States)

    Curnis, Antonio; Mascioli, Giosue; Bontempi, Luca; Cerini, Manuel; Bignotti, Tommaso; Bonetti, Gabriele; Dei Cas, Livio

    2008-12-01

    Implantable cardioverter-defibrillator (ICD) implant indications have widened in recent years after the publication of the Multicenter Automatic Defibrillator Implantation Trial 2 and the Sudden Cardiac Death in Heart Failure Trial. On the contrary, guidelines on resumption of driving after ICD implant were published almost 10 years ago when the ICD implant rate was much lower and candidates were generally older. The overall objective of our study was to evaluate whether patients implanted with ICDs have higher risk than the general driving population. The specific aim of the study was to verify the rate of car accidents in patients implanted with an ICD, both for primary and secondary indication, and compare this with the rate of accidents in the general population. The primary end point of the study was the annual car accident rate; the secondary end point was to determine if there were subgroups of patients with a higher risk of car accidents. All patients (612) followed up in our outpatient clinic were sent a questionnaire in which they were asked five questions regarding their driving habits before and after ICD implant and, specifically, whether they had been involved in a car accident after the implant. Two hundred eighty-six patients (47%) responded to the questionnaire. Seventy-one patients had never driven; two patients were forbidden to drive for professional reasons (one bus and one truck driver). Two hundred thirteen (74.5% of all responding) patients (201 men, mean age 62 +/- 11 years) continued to drive after ICD implant. During the follow-up (1430 +/- 920 days) 11 patients had been involved in car accidents and, importantly 10 out of 11 were innocent bystanders. Thus, in 996 patient-years, 11 events happened, yielding an annual event rate of 1.1% per patient-years (and only 0.1% in which the driver could had been responsible). Car accidents are infrequent in patients implanted with an ICD, and - in any case - not more frequent than in the general

  2. Impact of Moderate to Severe Renal Impairment on Mortality and Appropriate Shocks in Patients with Implantable Cardioverter Defibrillators

    Directory of Open Access Journals (Sweden)

    Venkata M. Alla

    2010-01-01

    Full Text Available Background. Due to underrepresentation of patients with chronic kidney disease (CKD in large Implantable-Cardioverter Defibrillator (ICD clinical trials, the impact of ICD remains uncertain in this population. Methods. Consecutive patients who received ICD at Creighton university medical center between years 2000–2004 were included in a retrospective cohort after excluding those on maintenance dialysis. Based on baseline Glomerular filtration rate (GFR, patients were classified as severe CKD: GFR < 30 mL/min; moderate CKD: GFR: 30–59 mL/min; and mild or no CKD: GFR ≥ 60 mL/min. The impact of GFR on appropriate shocks and survival was assessed using Kaplan-Meier method and Generalized Linear Models (GLM with log-link function. Results. There were 509 patients with a mean follow-up of 3.0 + 1.3 years. Mortality risk was inversely proportional to the estimated GFR: 2 fold higher risk with GFR between 30–59 mL/min and 5 fold higher risk with GFR < 30 mL/min. One hundred and seventy-seven patients received appropriate shock(s; appropriate shock-free survival was lower in patients with severe CKD (GFR < 30 compared to mild or no CKD group (2.8 versus 4.2 yrs. Conclusion. Even moderate renal dysfunction increases all cause mortality in CKD patients with ICD. Severe but not moderate CKD is an independent predictor for time to first appropriate shock.

  3. Interaction between shock coils increased the incidence of inappropriate therapies and lead failure in implantable cardioverter defibrillator.

    Science.gov (United States)

    El Garhy, Mohammad; Ohlow, Marc-Alexander; Lauer, Bernward

    Shock coil interaction in patients with multiple implantable cardioverter defibrillator (ICD) leads is occasionally observed. We aimed to evaluate the incidence of shock coil interaction and its clinical relevance. All ICD patients (646 patients) who came to follow up control in our ICD ambulance between January 1, 2011, and December 31, 2011 in the department of cardiology in Bad Berka hospital were retrospectively evaluated in this study. All baseline demographic, clinical, and procedural characteristics and postoperative chest x ray in postero-anterior and lateral view as well as clinical and ICD follow up data were evaluated. Among 646 patients 42 had multiple ICD leads (6.5%) of whom 36 patients (5.5% of total cohort patients and 85.7% of patients with multiple ICD leads) had shock coil interaction and presented the study group (Group I). The control group (Group II) consisted of 610 patients without coil-coil interaction including patients with single shock lead (604 patients) or patients with multiple leads but without interaction between shock coils (6 patients). Inappropriate anti-tachycardia therapies and RV lead revisions were more frequent in patients with interaction between shock coils (Group I vs Group II: 27.7% and 5.7%; p = 0.049 and 30.6% vs 6.4; p = 0.0001, respectively). Interaction between shock coils may be one of possible causes of lead failure and resulted in inappropriate therapies and subsequent lead revision. Copyright © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.

  4. Decision-Making of Patients With Implantable Cardioverter-Defibrillators at End of Life: Family Members' Experiences.

    Science.gov (United States)

    Lee, Mei Ching; Sulmasy, Daniel P; Gallo, Joseph; Kub, Joan; Hughes, Mark T; Russell, Stuart; Kellogg, Anela; Owens, Sharon G; Terry, Peter; Nolan, Marie T

    2017-07-01

    Many patients with advanced heart failure (HF) experience the life-extending benefits of implantable cardioverter-defibrillators (ICD), but at the end stage of HF, patients may experience shocks with increasing frequency and change the plan for end-of-life (EOL) care including the deactivation of the ICD. This report describes family members' experiences of patients with ICD making decisions at EOL. Understanding the decision-making of patients with ICD at EOL can promote informed decision-making and improve the quality of EOL care. This pilot study used a mixed methods approach to test the effects of a nurse-guided discussion in decision-making about ICD deactivation (turning off the defibrillation function) at the EOL. Interviews were conducted, audiotaped, and transcribed in 2012 to 2013 with 6 family members of patients with advanced HF and ICDs. Three researchers coded the data and identified themes in 2014. Three main themes described family members' experiences related to patients having HF with ICDs making health-care decision at EOL: decision-making preferences, patients' perception on ICD deactivation, and communication methods. Health-care providers need to have knowledge of patients' decision-making preferences. Preferences for decision-making include the allowing of appropriate people to involve and encourages direct conversation with family members even when advance directives is completed. Information of ICD function and the option of deactivation need to be clearly delivered to patients and family members. Education and guidelines will facilitate the communication of the preferences of EOL care.

  5. The healthcare utilization and cost of treating patients experiencing inappropriate implantable cardioverter defibrillator shocks: a propensity score study.

    Science.gov (United States)

    Bhavnani, Sanjeev P; Giedrimiene, Dalia; Coleman, Craig I; Guertin, Danette; Azeem, Meena; Kluger, Jeffrey

    2014-10-01

    Inappropriate shocks (IASs) from implantable cardioverter defibrillators (ICDs) are associated with decreased quality of life, but whether they increase healthcare utilization and treatment costs is unknown. We sought to determine the impact of IASs on subsequent healthcare utilization and treatment costs. We conducted a case-control analysis of ICD patients at a single institution from 1997 to 2010 and who had ≥12 months of post-ICD implant follow-up. Cases included all patients experiencing an IAS during the first 12 months after implantation. Eligible control patients did not receive a shock of any kind during the 12 months after implantation. Propensity scores based on 36 covariates (area under curve = 0.78) were used to match cases to controls. We compared the rate (occurrences/person year [PY]) of healthcare utilization immediately following IAS to the end of the 12-month follow-up period to the rate in the no-shock group over 12 months of follow-up. We also compared 12-month postimplant treatment (outpatient clinic, emergency room, and hospitalization) costs in both groups. A total of 76 patients experiencing ≥1 IAS during the first 12 months after implant (contributing 48 PYs) were matched to 76 no-shock patients (contributing 76 PYs). Cardiovascular (CV)-related clinic visit and hospitalization rates were increased following an IAS compared to those not receiving a shock (4.0 vs 3.3 and 0.7 vs 0.5, respectively, P = 0.02 for both). CV-related emergency room visitation (0.15 vs 0.08) rates were also numerically higher following an IAS, but did not reach statistical significance (P = 0.26). Patients experiencing an IAS accrued greater treatment costs during the 12 months postimplant compared to no-shock patients ($13,973 ± $46,345 vs $6,790 ± $19,091, P = 0.001). Recipients of IAS utilize the healthcare system more frequently following an IAS than patients not experiencing a shock. This increased utilization results in higher costs of treating IAS

  6. Performance of the 2015 International Task Force Consensus Statement Risk Stratification Algorithm for Implantable Cardioverter-Defibrillator Placement in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy.

    Science.gov (United States)

    Orgeron, Gabriela M; Te Riele, Anneline; Tichnell, Crystal; Wang, Weijia; Murray, Brittney; Bhonsale, Aditya; Judge, Daniel P; Kamel, Ihab R; Zimmerman, Stephan L; Tandri, Harikrishna; Calkins, Hugh; James, Cynthia A

    2018-02-01

    Ventricular arrhythmias are a feared complication of arrhythmogenic right ventricular dysplasia/cardiomyopathy. In 2015, an International Task Force Consensus Statement proposed a risk stratification algorithm for implantable cardioverter-defibrillator placement in arrhythmogenic right ventricular dysplasia/cardiomyopathy. To evaluate performance of the algorithm, 365 arrhythmogenic right ventricular dysplasia/cardiomyopathy patients were classified as having a Class I, IIa, IIb, or III indication per the algorithm at baseline. Survival free from sustained ventricular arrhythmia (VT/VF) in follow-up was the primary outcome. Incidence of ventricular fibrillation/flutter cycle length the algorithm appropriately differentiated risk of VT/VF, incidence of VT/VF was underestimated (observed versus expected: 29.6 [95% confidence interval, 25.2-34.0] versus >10%/year Class I; 15.5 [confidence interval 11.1-21.6] versus 1% to 10%/year Class IIa). In addition, the algorithm did not differentiate survival free from ventricular fibrillation/flutter between Class I and IIa patients ( P =0.97) or for VT/VF in Class I and IIa primary prevention patients ( P =0.22). Adding Holter results (the algorithm differentiates arrhythmic risk well overall, it did not distinguish ventricular fibrillation/flutter risks of patients with Class I and IIa implantable cardioverter-defibrillator indications. Limited differentiation was seen for primary prevention cases. As these are vital uncertainties in clinical decision-making, refinements to the algorithm are suggested prior to implementation. © 2018 American Heart Association, Inc.

  7. Methodological limitations of psychosocial interventions in patients with an implantable cardioverter-defibrillator (ICD A systematic review

    Directory of Open Access Journals (Sweden)

    Ockene Ira S

    2009-12-01

    Full Text Available Abstract Background Despite the potentially life-saving benefits of the implantable cardioverter-defibrillator (ICD, a significant group of patients experiences emotional distress after ICD implantation. Different psychosocial interventions have been employed to improve this condition, but previous reviews have suggested that methodological issues may limit the validity of such interventions. Aim: To review the methodology of previously published studies of psychosocial interventions in ICD patients, according to CONSORT statement guidelines for non-pharmacological interventions, and provide recommendations for future research. Methods We electronically searched the PubMed, PsycInfo and Cochrane databases. To be included, studies needed to be published in a peer-reviewed journal between 1980 and 2008, to involve a human population aged 18+ years and to have an experimental design. Results Twelve studies met the eligibility criteria. Samples were generally small. Interventions were very heterogeneous; most studies used cognitive behavioural therapy (CBT and exercise programs either as unique interventions or as part of a multi-component program. Overall, studies showed a favourable effect on anxiety (6/9 and depression (4/8. CBT appeared to be the most effective intervention. There was no effect on the number of shocks and arrhythmic events, probably because studies were not powered to detect such an effect. Physical functioning improved in the three studies evaluating this outcome. Lack of information about the indication for ICD implantation (primary vs. secondary prevention, limited or no information regarding use of anti-arrhythmic (9/12 and psychotropic (10/12 treatment, lack of assessments of providers' treatment fidelity (12/12 and patients' adherence to the intervention (11/12 were the most common methodological limitations. Conclusions Overall, this review supports preliminary evidence of a positive effect of psychosocial interventions

  8. Evaluation of acute cardiac and chest wall damage after shocks with a subcutaneous implantable cardioverter defibrillator in Swine.

    Science.gov (United States)

    Killingsworth, Cheryl R; Melnick, Sharon B; Litovsky, Silvio H; Ideker, Raymond E; Walcott, Gregory P

    2013-10-01

    A subcutaneous implantable cardioverter defibrillator (S-ICD) could ease placement and reduce complications of transvenous ICDs, but requires more energy than transvenous ICDs. Therefore we assessed cardiac and chest wall damage caused by the maximum energy shocks delivered by both types of clinical devices. During sinus rhythm, anesthetized pigs (38 ± 6 kg) received an S-ICD (n = 4) and five 80-Joule (J) shocks, or a transvenous ICD (control, n = 4) and five 35-J shocks. An inactive S-ICD electrode was implanted into the same control pigs to study implant trauma. All animals survived 24 hours. Troponin I and creatine kinase muscle isoenzyme (CK-MM) were measured as indicators of myocardial and skeletal muscle injury. Histopathological injury of heart, lungs, and chest wall was assessed using semiquantitative scoring. Troponin I was significantly elevated at 4 hours and 24 hours (22.6 ± 16.3 ng/mL and 3.1 ± 1.3 ng/mL; baseline 0.07 ± 0.09 ng/mL) in control pigs but not in S-ICD pigs (0.12 ± 0.11 ng/mL and 0.13 ± 0.13 ng/mL; baseline 0.06 ± 0.03 ng/mL). CK-MM was significantly elevated in S-ICD pigs after shocks (6,544 ± 1,496 U/L and 9,705 ± 6,240 U/L; baseline 704 ± 398 U/L) but not in controls. Electrocardiogram changes occurred postshock in controls but not in S-ICD pigs. The myocardium and lungs were histologically normal in both groups. Subcutaneous injury was greater in S-ICD compared to controls. Although CK-MM suggested more skeletal muscle injury in S-ICD pigs, significant cardiac, lung, and chest wall histopathological changes were not detected in either group. Troponin I data indicate significantly less cardiac injury from 80-J S-ICD shocks than 35-J transvenous shocks. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  9. Evaluation of acute cardiac and chest wall damage after shocks with a subcutaneous implantable cardioverter-defibrillator in swine

    Science.gov (United States)

    KILLINGSWORTH, CHERYL R.; MELNICK, SHARON B.; LITOVSKY, SILVIO H.; IDEKER, RAYMOND E.; WALCOTT, GREGORY P.

    2013-01-01

    Background A subcutaneous implantable cardioverter defibrillator (S-ICD) could ease placement and reduce complications of transvenous ICDs, but requires more energy than transvenous ICDs. Therefore we assessed cardiac and chest wall damage caused by the maximum energy shocks delivered by both types of clinical devices. Methods During sinus rhythm, anesthetized pigs (38±6 kg) received an S-ICD (n = 4) and five 80-Joule (J) shocks, or a transvenous ICD (control, n = 4) and five 35-J shocks. An inactive S-ICD electrode was implanted into the same control pigs to study implant trauma. All animals survived 24-hours. Troponin I and creatine kinase muscle isoenzyme (CK-MM) were measured as indicators of myocardial and skeletal muscle injury. Histopathological injury of heart, lungs, and chest wall was assessed using semi-quantitative scoring. Results Troponin I was significantly elevated at 4- and 24-hours (22.6±16.3 and 3.1±1.3 ng/ml; baseline 0.07±0.09 ng/ml) in control pigs but not in S-ICD pigs (0.12±0.11 and 0.13±0.13 ng/ml; baseline 0.06±0.03 ng/ml). CK-MM was significantly elevated in S-ICD pigs after shocks (6544±1496 and 9705±6240 U/L; baseline 704±398 U/L) but not in controls. ECG changes occurred post-shock in controls but not in S-ICD pigs. The myocardium and lungs were histologically normal in both groups. Subcutaneous injury was greater in S-ICD compared to controls. Conclusion Although CK-MM suggested more skeletal muscle injury in S-ICD pigs, significant cardiac, lung, and chest wall histopathological changes were not detected in either group. Troponin I data indicate significantly less cardiac injury from 80-J S-ICD shocks than 35-J transvenous shocks. PMID:23713608

  10. [Impact of metoprolol use in the treatment of patients with electrical-storm after cardioverter defibrillators implantation].

    Science.gov (United States)

    Yu, Jin-bo; Yang, Bing; Xu, Dong-jie; Chen, Ming-long; Shan, Qi-jun; Zou, Jian-gang; Chen, Chun; Zhang, Feng-xiang; Hou, Xiao-feng; Li, Wen-qi; Zhang, Rong; Cao, Ke-jiang

    2011-08-01

    To explore the effectiveness of the metoprolol dosage adjustment on reducing the incidence of electrical-storm (ES) in patients with Implantable Cardioverter Defibrillators (ICDs). Data from patients with ICD implantation between Jan, 2003 and Jun, 2006 in our hospital were retrospectively analyzed. ES was defined as either ≥ 3 times of ventricular tachyarrhythmias (VTAs) resulting in ICD therapy or VTAs lasting more than 30 s detected by ICD without any therapy within 24 hours. During a follow-up period of (27.5 ± 21.2) months, ES was recorded in 39 cases [34 males, average age (52.0 ± 13.1) years] out of 119 patients (32.8%) and 9 patients died after ES. During the period of storm attack, ES was successfully controlled in 25/30 patients by various interventions, including predisposing factors corrected in 5 cases, ICD reprogramming and antiarrhythmic drugs therapy optimized in 16 cases (one received intravenous injection of metoprolol), and VTAs eliminated by catheter ablation in 4 cases. ES was spontaneously resolved in the remaining 5 cases. In the chronic phase, 2 patients with Brugada syndrome were treated with Quinidine mono-therapy while the dosage of metoprolol was adjusted in the remaining 23 patients and the dosage of metoprolol was increased gradually from (26.8 ± 13.9) mg/d to (88.9 ± 53.5) mg/d without any adverse effects (9 patients received also oral amiodarone 200 mg/d). Post dosage adjustment, the total VTA episodes [(1.9 ± 1.7) times/month vs. (0.8 ± 0.6) times/month, P = 0.004], incidence of antitachycardia pacing therapies [(4.2 ± 3.8) runs/month vs. (2.3 ± 2.0) runs/month, P = 0.003], as well as electrical cardioversion or defibrillation [(1.1 ± 0.9) times/month vs. (0.4 ± 0.2) times/month, P = 0.001] were significantly decreased. ES was not controlled until a extremely high dosage [225 - 300 (255.3 ± 41.7) mg/d] of metoprolol was reached in the remaining 5 patients. Metoprolol use is essential and its dosage should be

  11. Nurse- and peer-led self-management programme for patients with an implantable cardioverter defibrillator; a feasibility study

    Directory of Open Access Journals (Sweden)

    van Eijk Jacques

    2007-09-01

    Full Text Available Abstract Background The prevalence of cardiovascular disease is increasing. Improved treatment options increase survival after an acute myocardial infarction or sudden cardiac arrest, although patients often have difficulty adjusting and regaining control in daily life. In particular, patients who received an implantable cardioverter defibrillator (ICD experience physical and psychological problems. Interventions to enhance perceived control and acceptance of the device are therefore necessary. This paper describes a small-scale study to explore the feasibility and the possible benefits of a structured nurse- and peer-led self-management programme ('Chronic Disease Self-Management Program' – CDSMP among ICD patients. Methods Ten male ICD patients (mean age = 65.5 years participated in a group programme, consisting of six sessions, led by a team consisting of a nurse specialist and a patient with cardiovascular disease. Programme feasibility was evaluated among patients and leaders by measuring performance of the intervention according to protocol, attendance and adherence of the participating ICD patients, and patients' and leaders' opinions about the programme. In addition, before and directly after attending the intervention, programme benefits (e.g. perceived control, symptoms of anxiety and depression, and quality of life were assessed. Results The programme was conducted largely according to protocol. Eight patients attended at least four sessions, and adherence ranged from good to very good. On average, the patients reported to have benefited very much from the programme, which they gave an overall report mark of 8.4. The leaders considered the programme feasible as well. Furthermore, improvements were identified for general self-efficacy expectancies, symptoms of anxiety, physical functioning, social functioning, role limitations due to physical problems, and pain. Conclusion This study suggests that a self-management programme led by a

  12. Do implantable cardioverter defibrillators improve survival in patients with severe left ventricular systolic dysfunction after coronary artery bypass graft surgery?

    Science.gov (United States)

    Fazal, Iftikhar A; Bates, Matthew G D; Matthews, Iain G; Turley, Andrew J

    2011-06-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether implantable cardioverter defibrillators (ICD) improve survival in patients with severe left ventricular systolic dysfunction (LVSD) after coronary artery bypass graft (CABG) surgery. ICDs are designed to terminate potentially fatal cardiac tachyarrhythmias. A right ventricular lead is mandatory for detection, pacing and defibrillation capabilities. Dual chamber ICDs have an additional right atrial lead and are used for patients with conventional atrioventricular pacing indications. More sophisticated, biventricular devices exist to provide cardiac resynchronisation therapy (CRT) in addition to defibrillation (CRT-D). ICDs have been extensively investigated in patients with LVSD post myocardial infarction and in patients with non-ischaemic cardiomyopathy for both secondary prevention (history of ventricular arrhythmias) and primary prevention (deemed high risk for ventricular arrhythmias). This best evidence topic aims to review the evidence and its applicability to patients post CABG. Nine hundred and sixteen papers were identified using the search method outlined. Eight randomised controlled trials, two meta-analyses, and one non-randomised trial, in addition to international guidelines presented the best evidence to answer the clinical question. The current evidence base and guidelines suggest that ICDs should be considered for all patients with LVSD [ejection fraction (EF) ≤30-40%] receiving optimal pharmacological management, who are ≥40 days post MI [four weeks for National Institute for Health and Clinical Excellence (NICE)] and in New York Heart Association (NYHA) class I-III. UK NICE guidelines require in addition; non-sustained ventricular tachycardia (NSVT) on a Holter monitor and inducible ventricular tachycardia at electrophysiological study for EF between 30 and 35%; or a QRS >120 ms if EF <30%. The North American guidelines

  13. In vitro assessment of the immunity of implantable cardioverter-defibrillators to magnetic fields of 50/60 Hz.

    Science.gov (United States)

    Katrib, J; Nadi, M; Kourtiche, D; Magne, I; Schmitt, P; Souques, M; Roth, P

    2013-10-01

    Public concern for the compatibility of electromagnetic (EM) sources with active implantable medical devices (AIMD) has prompted the development of new systems that can perform accurate exposure studies. EM field interference with active cardiac implants (e.g. implantable cardioverter-defibrillators (ICDs)) can be critical. This paper describes a magnetic field (MF) exposure system and the method developed for testing the immunity of ICD to continuous-wave MFs. The MFs were created by Helmholtz coils, housed in a Faraday cage. The coils were able to produce highly uniform MFs up to 4000 µT at 50 Hz and 3900 µT at 60 Hz, within the test space. Four ICDs were tested. No dysfunctions were found in the generated MFs. These results confirm that the tested ICDs were immune to low frequency MFs.

  14. Current state of knowledge and experts' perspective on the subcutaneous implantable cardioverter-defibrillator.

    Science.gov (United States)

    Santini, Massimo; Cappato, Riccardo; Andresen, Dietrich; Brachmann, Johannes; Davies, D Wyn; Cleland, John; Filippi, Alessandro; Gronda, Edoardo; Hauer, Richard; Steinbeck, Gerhard; Steinhaus, David

    2009-06-01

    ICD implantation is today a well-recognized therapy to prevent sudden cardiac death. The available implantable devices at present need the use of permanent endocavitary leads which may cause, in some instances, serious troubles to the patients (lead dislodgement, ventricular perforation, lead infections, etc.). A new implantable defibrillator provided by only a subcutaneous lead is at present under evaluation. Its potential indications, usefulness benefits, and problems represent an interesting field of investigation and discussion. This paper describes the conclusions recently reached by a panel of experts, with regard to the potential role of an implantable subcutaneous defibrillator in the prevention of sudden cardiac death.

  15. Inappropriate implantable cardioverter-defibrillator shocks in Brugada syndrome: Pattern in primary and secondary prevention

    Directory of Open Access Journals (Sweden)

    Aimé Bonny

    2017-01-01

    Conclusion: Inappropriate shock is common in Brugada syndrome during the early periods after an ICD implantation, and seems to be more likely in asymptomatic patients. This finding may warrant a review of the indications for ICD implantation, especially in the young and apparently healthy population of patients with Brugada syndrome.

  16. Effect of defibrillation threshold testing on effectiveness of the subcutaneous implantable cardioverter defibrillator.

    Science.gov (United States)

    Peddareddy, Lakshmi; Merchant, Faisal M; Leon, Angel R; Smith, Paige; Patel, Akshar; El-Chami, Mikhael F

    2018-06-12

    Defibrillation threshold (DFT) testing is recommended with the subcutaneous ICD (SICD). To describe first shock efficacy for appropriate SICD therapies stratified by the presence of implant DFT testing. We reviewed all patients receiving SICDs at our institution and stratified them based on whether implant DFT testing was performed. Appropriate shocks were reviewed to see if ventricular tachycardia/ventricular fibrillation (VT/VF) terminated with a single shock. First shock efficacy was stratified by implant DFT status. 178 patients implanted with SICDs and followed in our center were included in this study. Of these, 135 (76 %) underwent DFT testing (DFT (+) group). In the DFT (+) 80 appropriate shocks were needed to treat 69 episodes of VT/VF. The first shock was effective in 61 out of 69 episodes (88.4 %), whereas multiple shocks were required to terminate VT/VF in the remaining 8 episodes. Among 43 patients without implant DFT testing (DFT (-) group), 20 appropriate shocks to treat 17 episodes of VT/VF occurred in 7 patients. VT/VF was successfully terminated with the first shock in 16 out of 17 episodes (first shock efficacy 94.1 %). There was no significant difference in first shock effectiveness between those with and without implant DFT testing (p = 0.97). A strategy that omits DFT testing at implant did not appear to compromise the effictiveness of the SICD. These data suggest that routine DFT testing at SICD implant might not be necessary. Randomized trials are needed to confirm this finding. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  17. Results of ENHANCED Implantable Cardioverter Defibrillator Programming to Reduce Therapies and Improve Quality of Life (from the ENHANCED-ICD Study)

    DEFF Research Database (Denmark)

    Mastenbroek, Mirjam H.; Pedersen, Susanne S.; van der Tweel, Ingeborg

    2016-01-01

    -reported outcomes. The "ENHANCED Implantable Cardioverter Defibrillator programming to reduce therapies and improve quality of life" study (ENHANCED-ICD study) was a prospective, safety-monitoring study enrolling 60 primary and secondary prevention patients at the University Medical Center Utrecht. Patients...... programming strategy, unnecessary ICD therapy was prevented in 10% of ENHANCED-ICD patients during a median follow-up period of 1.3 years. With respect to patient-reported outcomes, levels of distress were highest and perceived health status lowest at the time of implantation, which both gradually improved...... during follow-up. In conclusion, the ENHANCED-ICD study demonstrates that programming a NID 60/80 for VT/VF detection is safe for ICD patients and does not negatively impact their quality of life....

  18. Implantable cardioverter defibrillators in the context of hypertrophic cardiomyopathy: a lesson in patient autonomy.

    Science.gov (United States)

    Bray, Jonathan James Hyett; Bucciarelli-Ducci, Chiara; Stuart, Graham

    2018-02-05

    Hypertrophiccardiomyopathy (HCM) is common, whereas the decision not to have an implantable cardioverterdefibrillator (ICD) when probably falling into a 'high-risk' category is not. A solicitor aged 45 years attended the inherited cardiac conditions clinic for review of her HCM and discussion about ICD implantation for primary prevention of sudden cardiac death (SCD). Despite a predicted 7% risk of SCD within the next 5 years, according to the European Society of Cardiology endorsed HCM Risk-SCD risk stratification tool, the patient opted against implantation of an ICD and comprehensively justifies her decision. This report discusses ethical aspects of a consultation offering ICD protection against SCD in the context of HCM and emphasises the clinicians' role in respecting patient autonomy. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Quality of Life and Psychological Factors in Patients with Implantable Cardioverter Defibrillator

    Directory of Open Access Journals (Sweden)

    Akiko Suyama-Chishaki, MD PhD

    2007-01-01

    CONCLUSION: To support ICD recipients both physically and mentally, not only the cardiologists but also specialists from other fields such as psychologists and nurse specialists are needed. Ancillary care must be provided through the support team. Cardiologists who determine whether ICD implantation is required must keep in mind potential psychological sequelae.

  20. A clinical example of extreme dose exposure for an implanted cardioverter-defibrillator. Beyond the DEGRO guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hristova, Yoana; Koehn, Janett; Preuss, Stefanie [Johann Wolfgang Goethe University Frankfurt, Department of Radiation Oncology, University Hospital, Frankfurt (Germany); Roedel, Claus; Balermpas, Panagiotis [Johann Wolfgang Goethe University Frankfurt, Department of Radiation Oncology, University Hospital, Frankfurt (Germany); German Cancer Research Center (DKFZ), Heidelberg (Germany); German Cancer Consortium (DKTK), Frankfurt am Main (Germany)

    2017-09-15

    Considering that the number of malignant diseases in patients over 65 years of age is increasing, it often occurs that patients who carry a cardiac implanted electronic device must undergo radiotherapy. Ionizing radiation can disturb the function of the implantable cardioverter-defibrillator (ICD). As a result of this, an update of the DEGRO/DKG guidelines for radiotherapy of this patient group has been published. We report the case of a patient with an ICD and T-lymphoblastic lymphoma with cardiac involvement, who received i.a. a total body irradiation with 8 Gy followed by a consolidating radiotherapy of the pericardium with 14 Gy as well as additional radiotherapy courses after consecutive recurrences. For the purposes of the treatment, the antitachyarrhythmia (ATA) therapy was deactivated and temporarily replaced through a life vest. According to the current DEGRO guidelines for irradiation of patients with cardiac implanted electronic devices, a categorization of the patient in the ''high-risk'' group was made. Furthermore, regular telemetric checks of the ICD device were performed before and after treatment. Despite unavailable declaration of the manufacturer regarding the cumulative tolerable dose and DEGRO recommendation for a cumulative dose <2 Gy, the aftercare was unproblematic and normal values were assessed for all relevant ICD parameters, despite a cumulative dose >10 Gy in the device. This case shows that if the cardiac implanted electronic devices are not directly irradiated und the energy used is reduced to 6 MV, irradiation-induced damage is less likely and can possibly be prevented. (orig.) [German] Vor dem Hintergrund der steigenden Zahl von Krebserkrankungen bei Patienten ueber 65 Jahren kommt es haeufig vor, dass sich Patienten mit einem kardialen implantierten elektronischen Geraet einer Strahlentherapie unterziehen muessen. Ionisierende Strahlung kann die Funktion des implantierbaren Kardioverter-Defibrillators (ICD

  1. Implantable Cardioverter-defibrillator Therapy for Hypertrophic Cardiomyopathy: Usefulness in Primary and Secondary Prevention.

    Science.gov (United States)

    Sarrias, Axel; Galve, Enrique; Sabaté, Xavier; Moya, Àngel; Anguera, Ignacio; Núñez, Elaine; Villuendas, Roger; Alcalde, Óscar; García-Dorado, David

    2015-06-01

    Hypertrophic cardiomyopathy is a frequent cause of sudden death. Clinical practice guidelines indicate defibrillator implantation for primary prevention in patients with 1 or more risk factors and for secondary prevention in patients with a history of aborted sudden death or sustained ventricular arrhythmias. The aim of the present study was to analyze the follow-up of patients who received an implantable defibrillator following the current guidelines in nonreferral centers for this disease. This retrospective observational study included all patients who underwent defibrillator implantation between January 1996 and December 2012 in 3 centers in the province of Barcelona. The study included 69 patients (mean age [standard deviation], 44.8 [17] years; 79.3% men), 48 in primary prevention and 21 in secondary prevention. The mean number of risk factors per patient was 1.8 in the primary prevention group and 0.5 in the secondary prevention group (P=.029). The median follow-up duration was 40.5 months. The appropriate therapy rate was 32.7/100 patient-years in secondary prevention and 1.7/100 patient-years in primary prevention (P<.001). Overall mortality was 10.1%. Implant-related complications were experienced by 8.7% of patients, and 13% had inappropriate defibrillator discharges. In patients with a defibrillator for primary prevention, the appropriate therapy rate is extremely low, indicating the low predictive power of the current risk stratification criteria. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  2. Long-Term Evaluation of Biotronik Linox and Linox(smart) Implantable Cardioverter Defibrillator Leads.

    Science.gov (United States)

    Good, Eric D; Cakulev, Ivan; Orlov, Michael V; Hirsh, David; Simeles, John; Mohr, Kelly; Moll, Phil; Bloom, Heather

    2016-06-01

    Expert consensus holds that post-market, systematic surveillance of ICD leads is essential to ensure confirmation of adequate lead performance. GALAXY (NCT00836589) and CELESTIAL (NCT00810264) are ongoing multicenter, prospective, non-randomized registries conducted to confirm the long-term safety and reliability of Biotronik leads. ICD and CRT-D patients are followed for Linox and Linox(smart) ICD lead performance and safety for 5 years post-implant. All procedural and system-related adverse events (AEs) were assessed at each follow-up, along with lead electrical parameters. An independent CEC of EPs adjudicated AEs to determine AE category and lead relatedness. The analysis used categories of lead observations per ISO 5841-2 (Third edition). A total of 3,933 leads were implanted in 3,840 patients (73.0% male, mean age 67.0 ± 12.2 years) at 146 US centers. The estimated cumulative survival probability was 96.3% at 5 years after implant for Linox leads and 96.6% at 4 years after implant for Linox(smart) leads. A comparison of the Linox and Linox(smart) survival functions did not find evidence of a difference (P = 0.2155). The most common AEs were oversensing (23, 0.58%), conductor fracture (14, 0.36%), failure to capture (13, 0.33%), lead dislodgement (12, 0.31%), insulation breach (10, 0.25%), and abnormal pacing impedance (8, 0.20%). Linox and Linox(smart) ICD leads are safe, reliable and infrequently associated with lead-related AEs. Additionally, estimated cumulative survival probability is clinically acceptable and well within industry standards. Ongoing data collection will confirm the longer-term safety and performance of the Linox family of ICD leads. © 2016 Wiley Periodicals, Inc.

  3. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator.

    Science.gov (United States)

    Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J; Jordaens, Luc; Pedersen, Susanne S

    2012-01-01

    Beta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress. We investigated the association between beta-blocker therapy, including type and dosage, and symptoms of anxiety and depression in a consecutive cohort of patients receiving an ICD. Between 2003 and 2010, 448 consecutively implanted ICD patients were enrolled in the prospective Mood and personality as precipitants of arrhythmia in patients with an Implantable cardioverter Defibrillator: A prospective Study (MIDAS), of which 429 completed the Hospital Anxiety and Depression Scale (HADS) and the ICD Patient Concerns questionnaire (ICDC) at baseline. Eighty per cent of all patients received beta-blocker therapy. In univariate analysis, beta-blocker therapy was not significantly associated with symptoms of anxiety, depression, and ICD concerns (β = -0.030, β = 0.007, and β = -0.045, respectively; all P's >0.36). Type of beta-blocker showed a trend towards significance for mean levels of ICD concerns (P = 0.09). No association was found between dosage and emotional distress (all P's >0.21). After adjustment for relevant clinical and demographic variables, the association of beta-blocker therapy and symptoms of anxiety, depression, and ICD concerns remained non-significant (β = 0.009, β = 0.037, and β = 0.019, respectively; all P's >0.47). In patients receiving an ICD, beta-blocker therapy was not associated with symptoms of anxiety, depression, and ICD concerns. Research is warranted that further elucidates the link between beta-blocker therapy and emotional distress in this vulnerable patient group.

  4. Clinical and psychological impact of prophylactic implantable cardioverter-defibrillators in a community heart failure population.

    LENUS (Irish Health Repository)

    Arnous, S

    2012-02-01

    AIMS: ICD implantation for primary prevention of sudden cardiac death in patients with left ventricular systolic dysfunction (ejection fraction <\\/= 35%) has increased since the publication of the SCD-HEFT and MADIT-II data. The aim of this study is to examine the effectiveness and safety of prophylactic ICD use in a community heart failure population and to assess the impact on patient\\'s quality of life. METHODS AND RESULTS: Seventy-one ICDs were inserted between the years 2002 and 2006. The mean follow-up from time of insertion was 24 +\\/- 11 months. Eighteen patients (25%) had potentially life-saving therapy. Seven (10%) patients received inappropriate shocks. Complications were encountered in five patients (7%). CONCLUSION: In a community heart failure population, prophylactic ICD implantation is associated with a high incidence of life-saving therapy, a low complication rate and a high level of tolerability. These data indicate translation of clinical trial benefits to the general heart failure population.

  5. Pacemakers and implantable cardioverter defibrillators, unknown to chest radiography: Review, complications and systematic reading

    International Nuclear Information System (INIS)

    Alandete Germán, Salvador Pascual; Isarria Vidal, Santiago; Domingo Montañana, María Luisa; De la vía Oraá, Esperanza; Vilar Samper, José

    2015-01-01

    Highlights: •Radiologists have an important function in the evaluation of these devices. •We revise their radiological appearances and possible complications. •The knowledge in normal aspects and complications is important for radiologist. •To ensure an accurate reading of the chest x-ray, we present a systematic approach. -- Abstract: Chest X-ray is the imaging technique of choice for an initial study of pacemakers and implantable cardio-defibrillators (ICD). Radiologists have an important role in the evaluation of its initial placement and in the assessment during its follow-up. For this reason, it is necessary to know not only the different existing devices and its components but also the reasons of malfunction or possible complications. The purpose of this article is to do a systematic review of the different types of pacemakers and ICD. We review their usual radiological appearances, the possible complications which might take place and its causes of malfunctioning

  6. [Nurses and doctors in the management of arrhytmic complications: the case of electric storm in patients with an implantable cardioverter defibrillator].

    Science.gov (United States)

    Plebani, Laura; Occhetta, Eraldo

    2006-01-01

    The evolution of arrhythmologic technology introduced new therapeutic opportunities for cardiology patients. Competence, continuity of care, integration and collaboration between medical doctors and nurses allow a safe management of short and long term complications. A typical example of a new arrhythmic complication is the "electrical storm" or "arrhythmic warm up" in patients implanted with a cardioverter-defibrillator (ICD). The definition and epidemiology of the electrical storm stress the relevance of this clinical situation; its dramatic emergency involves several aspects of nursing care, clinical, prognostic, ethical and deontological. The definition and implementation of an integrated protocol for the treatment of this condition is described and ethical and unresolved questions are rised. One of these problems is the recommendation to offer the patient the opportunity to receive information about the option of inactivating the ICD.

  7. A comparison of the health status and psychological distress of partners of patients with a left ventricular assist device versus an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Brouwers, Corline; Caliskan, Kadir; de Jonge, Nicolaas

    2014-01-01

    (F = 10.71, p = .001) but poorer mental health status (F = 14.82, p depression scores compared to ICD partners (F = 3.68, p = .05) at 6 months follow-up, also in adjusted analyses. There was no significant difference between groups on anxiety. CONCLUSION: Caregivers of LVAD......OBJECTIVE: To examine if the caregiving for patients with a left ventricular assist device (LVAD) is related to a poorer health status and more distress compared to patients with an implantable cardioverter defibrillator (ICD). BACKGROUND: Partners distress may influence patient outcomes...... and is therefore an important aspect in the care of LVAD and ICD patients. METHODS: Multi-center prospective observational study with 6 months follow-up of 33 LVAD partners (27% men; mean age = 54 ± 10 years) and 414 ICD partners (22% men; mean age = 60 ± 12 years). RESULTS: LVAD partners reported better physical...

  8. The effect of intermittent atrial tachyarrhythmia on heart failure or death in cardiac resynchronization therapy with defibrillator versus implantable cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine; Pietrasik, Grzegorz; Goldenberg, Ilan

    2014-01-01

    OBJECTIVES: This study aimed to investigate the effect of both history of intermittent atrial tachyarrhythmias (IAT) and in-trial IAT on the risk of heart failure (HF) or death comparing cardiac resynchronization therapy with defibrillator (CRT-D) to implantable cardioverter-defibrillator (ICD......) treatment in mildly symptomatic HF patients with left bundle branch block (LBBB). BACKGROUND: Limited data exist regarding the benefit of CRT-D in patients with IAT. METHODS: The benefit of CRT-D in reducing the risk of HF/death was evaluated using multivariate Cox models incorporating the presence of......-D versus ICD on the risk of HF/death was not significantly different between LBBB patients with or without history of IAT (HR: 0.50, p = 0.028, and HR: 0.46, p

  9. Is modification of the VVI backup mode in implantable cardioverter-defibrillators from St Jude medical required due to increased risk of inappropriate shocks?

    DEFF Research Database (Denmark)

    Philbert, Berit Thornvig; Tfelt-Hansen, Jacob; Jacobsen, Peter K

    2017-01-01

    Inappropriate implantable cardioverter-defibrillator (ICD) shock therapy is painful, stressful, and typically occurs unexpected in conscious patients and may be related to a less favourable prognosis. In our institution, we have observed four cases of multiple inappropriate ICD shocks during reset...... a ventricular fibrillation (VF) zone starting at 146 b.p.m., with shock therapy only and changes in sensitivity settings making the ICD more sensitive. In all cases, the reason for the multiple inappropriate shocks was that the VF zone was reached due to exercise-induced sinus tachycardia or due to oversensing...... during sinus rhythm. The VVI backup mode has to balance between protection from failure of ICD therapy during life-threatening ventricular arrhythmias and from inappropriate shocks. It seems the non-programmable parameters in VVI backup mode of St Jude Medical ICDs carry an unacceptable high risk...

  10. [The daily experience of the patient with an implantable cardioverter defibrillator].

    Science.gov (United States)

    Palacios-Ceña, Domingo; Alonso-Blanco, Cristina; Cachón-Pérez, José Miguel; Alvarez-López, Cristina

    2010-01-01

    To describe the daily experience of patients with an automatic defibrillator (AD) implant and the adaptive changes of the patient. Qualitative and phenomenological research. Collection of data through; initially unstructured interview with half of the informants, semi-structured interviews through an open questions guide after the initial unstructured interviews and use of personal narratives of the informants. Analysis of the data using the Van Manen proposal. We analysed the interviews of 10 participants. We collected socio-demographic variables and identified the following themes, which respond to the question "How is life with an AD": It is life "with the two sides of the coin," living in constant wait and uncertainty, accepting change, developing adaptation strategies, renegotiating relationships and sexuality and it is to live transformed. The results of this study can be integrated into nurse clinical practice in areas such as valuation after discharge, changes in habits, control of treatment, notification of shocks, masking detection of symptoms and strategies that can jeopardise the bearer. Research needs to be developed that looks closer into the influence of other technological devices in people. Copyright 2009 Elsevier España, S.L. All rights reserved.

  11. Merits and limitations of the mode switching rate stabilization pacing algorithms in the implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2001-09-01

    The 7250 Jewel AF Medtronic model of ICD is the first implantable device in which both therapies for atrial arrhythmias and pacing algorithms for atrial arrhythmia prevention are available. Feasibility of that extensive atrial arrhythmia management requires correct and synergic functioning of different algorithms to control arrhythmias. The ability of the new pacing algorithms to stabilize the atrial rate following termination of treated atrial arrhythmias was evaluated in the marker channel registration of 600 spontaneously occurring episodes in 15 patients with the Jewel AF. All patients (55+/-15 years) had structural heart disease and documented atrial and ventricular arrhythmias. Dual chamber rate stabilization pacing was present in 245 (41 %) of episodes following arrhythmia termination and was a part of the mode switching operation during which pacing was provided in the dynamic DDI mode. This algorithm could function as the atrial rate stabilization pacing only when there was a slow spontaneous atrial rhythm or in presence of atrial premature beats conducted to the ventricles with a normal AV time. In case of atrial premature beats with delayed or absent conduction to the ventricles and in case of ventricular premature beats, the algorithm stabilized the ventricular rate. The rate stabilization pacing in DDI mode during sinus rhythm following atrial arrhythmia termination was often extended in time due to the device-based definition of arrhythmia termination. This was also the case in patients, in whom the DDD mode with true atrial rate stabilization algorithm was programmed. The rate stabilization algorithms in the Jewel AF applied after atrial arrhythmia termination provide pacing that is not based on the timing of atrial events. Only under certain circumstances the algorithm can function as atrial rate stabilization pacing. Adjustments in availability and functioning of the rate stabilization algorithms might be of benefit for the clinical performance of

  12. Implantable Cardioverter Defibrillator

    Science.gov (United States)

    ... interfere with an ICD include: Cell phones and MP3 players (for example, iPods) Household appliances, such as ... experts recommend not putting your cell phone or MP3 player in a shirt pocket over your ICD ( ...

  13. Radiation therapy in patients with cardiac pacemakers or implantable cardioverter defibrillators. Interdisciplinary safety recommendations; Strahlentherapie bei Patienten mit Herzschrittmachern oder implantierbaren Kardioverter-Defibrillatoren. Interdisziplinaere Sicherheitsempfehlungen

    Energy Technology Data Exchange (ETDEWEB)

    Dorenkamp, M.; Haverkmap, W.; Roser, M. [Charite Universitaetsmedizin Berlin, Campus Virchow-Klinikum (Germany). Medizinische Klinik mit Schwerpunkt Kardiologie; Stromberger, C.; Wust, P. [Charite Universitaetsmedizin Berlin (Germany). Klinik fuer Radioonkologie und Strahlentherapie; Heymann, C. von [Charite Universitaetsmedizin Berlin, Campus Virchow-Klinikum (Germany). Klinik fuer Anaesthesiologie mit Schwerpunkt operative Intensivmedizin

    2013-01-15

    Background: With increasing numbers of implanted pacemakers and implantable cardioverter defibrillators (ICD) and a rising incidence of malignant tumors, there is a growing probability of radiation-mediated device dysfunction. The only guidelines for the management of patients with cardiac pacemakers in the case of radiation therapy were published in 1994 and have not been updated since then. Based on the current evidence and modern device technology, the present paper aims to develop contemporary and interdisciplinary safety recommendations for the minimization of patient risk. Methods and results: A systematic literature research was carried out including the most relevant medical electronic databases. The search yielded 147 articles published between 1994 and 2012 of which 45 met the selection criteria and of these studies 34 presented primary data (9 in vitro and 25 in vivo studies). The impact of ionizing radiation varied significantly between implanted devices and ranged from no functional changes to complete loss of function. Important device dysfunctions included changes in sensing capability, altered pacing pulses or rate, changed or disabled tachyarrhythmia ICD therapies, early battery depletion and loss of telemetry. Modern pacemakers and ICDs are more sensitive to radiation than older models. Potentially life-threatening complications were observed after exposure of the pulse generator to comparatively low radiation doses (0.11 Gy). Conclusions: Practical recommendations for patient management and safety are presented that can be readily adopted by any institution carrying out radiation therapy. (orig.)

  14. Somatosensory amplification mediates sex differences in psychological distress among cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Versteeg, Henneke; Baumert, Jens; Kolb, Christof

    2010-01-01

    The present study examined whether female patients with an implantable cardioverter defibrillator (ICD) report more psychological distress than male patients, and whether somatosensory amplification mediates this relationship. Design: Consecutive ICD patients (N = 241; 33% women) participating in...

  15. Importance of beta-blocker dose in prevention of ventricular tachyarrhythmias, heart failure hospitalizations, and death in primary prevention implantable cardioverter-defibrillator recipients

    DEFF Research Database (Denmark)

    Ruwald, A C; Gislason, G H; Vinther, M

    2018-01-01

    Aims: There is a paucity of studies investigating a dose-dependent association between beta-blocker therapy and risk of outcome. In a nationwide cohort of primary prevention implantable cardioverter-defibrillator (ICD) patients, we aimed to investigate the dose-dependent association between beta-blocker...... therapy and risk of ventricular tachyarrhythmias (VT/VF), heart failure (HF) hospitalizations, and death. Methods and results: Information on ICD implantation, endpoints, comorbidities, beta-blocker usage, type, and dose were obtained through Danish nationwide registers. The two major beta-blockers...... carvedilol and metoprolol were examined in three dose levels; low (metoprolol ≤ 25 mg; carvedilol ≤ 12.5 mg), intermediate (metoprolol 26-199 mg; carvedilol 12.6-49.9 mg), and high (metoprolol ≥ 200 mg; carvedilol ≥ 50 mg). Time to events was investigated utilizing multivariate Cox models with beta-blocker...

  16. Appropriate evaluation and treatment of heart failure patients after implantable cardioverter-defibrillator discharge: time to go beyond the initial shock.

    Science.gov (United States)

    Mishkin, Joseph D; Saxonhouse, Sherry J; Woo, Gregory W; Burkart, Thomas A; Miles, William M; Conti, Jamie B; Schofield, Richard S; Sears, Samuel F; Aranda, Juan M

    2009-11-24

    Multiple clinical trials support the use of implantable cardioverter-defibrillators (ICDs) for prevention of sudden cardiac death in patients with heart failure (HF). Unfortunately, several complicating issues have arisen from the universal use of ICDs in HF patients. An estimated 20% to 35% of HF patients who receive an ICD for primary prevention will experience an appropriate shock within 1 to 3 years of implant, and one-third of patients will experience an inappropriate shock. An ICD shock is associated with a 2- to 5-fold increase in mortality, with the most common cause being progressive HF. The median time from initial ICD shock to death ranges from 168 to 294 days depending on HF etiology and the appropriateness of the ICD therapy. Despite this prognosis, current guidelines do not provide a clear stepwise approach to managing these high-risk patients. An ICD shock increases HF event risk and should trigger a thorough evaluation to determine the etiology of the shock and guide subsequent therapeutic interventions. Several combinations of pharmacologic and device-based interventions such as adding amiodarone to baseline beta-blocker therapy, adjusting ICD sensitivity, and employing antitachycardia pacing may reduce future appropriate and inappropriate shocks. Aggressive HF surveillance and management is required after an ICD shock, as the risk of sudden cardiac death is transformed to an increased HF event risk.

  17. Unmappable ventricular tachycardia after an old myocardial infarction. Long-term results of substrate modification in patients with an implantable cardioverter defibrillator.

    Science.gov (United States)

    Alzand, B S N; Timmermans, C C M M; Wellens, H J J; Dennert, R; Philippens, S A M; Portegijs, P J M; Rodriguez, L M

    2011-08-01

    The frequent occurrence of ventricular tachycardia can create a serious problem in patients with an implantable cardioverter defibrillator. We assessed the long-term efficacy of catheter-based substrate modification using the voltage mapping technique of infarct-related ventricular tachycardia and recurrent device therapy. The study population consisted of 27 consecutive patients (age 68 ± 8 years, 25 men, mean left ventricular ejection fraction 31 ± 9%) with an old myocardial infarction and multiple and/or hemodynamically not tolerated ventricular tachycardia necessitating repeated device therapy. A total of 31 substrate modification procedures were performed using the three-dimensional electroanatomical mapping system. Patients were followed up for a median of 23.5 (interquartile range 6.5-53.2) months before and 37.8 (interquartile range 11.7-71.8) months after ablation. Antiarrhythmic drugs were not changed after the procedure, and were stopped 6 to 9 months after the procedure in patients who did not show ventricular tachycardia recurrence. Median ventricular tachycardias were 1.6 (interquartile range 0.7-6.7) per month before and 0.2 (interquartile range 0.00-1.3) per month after ablation (P = 0.006). Nine ventricular fibrillation episodes were registered in seven patients before and two after ablation (P = 0.025). Median antitachycardia pacing decreased from 1.6 (interquartile range 0.01-5.5) per month before to 0.18 (interquartile range 0.00-1.6) per month after ablation (P = 0.069). Median number of shocks decreased from 0.19 (interquartile range 0.04-0.81) per month before to 0.00 (interquartile range 0.00-0.09) per month after ablation (P = 0.001). One patient had a transient ischemic attack during the procedure, and another developed pericarditis. Nine patients died during follow-up, eight patients due to heart failure and one patient during valve surgery. Catheter-based substrate modification using voltage mapping results in a long-lasting reduction

  18. Contemporary rates and outcomes of single- vs. dual-coil implantable cardioverter defibrillator lead implantation: data from the Israeli ICD Registry.

    Science.gov (United States)

    Leshem, Eran; Suleiman, Mahmoud; Laish-Farkash, Avishag; Konstantino, Yuval; Glikson, Michael; Barsheshet, Alon; Goldenberg, Ilan; Michowitz, Yoav

    2017-09-01

    Dual-coil leads were traditionally considered standard of care due to lower defibrillation thresholds (DFT). Higher complication rates during extraction with parallel progression in implantable cardioverter defibrillator (ICD) technology raised questions on dual coil necessity. Prior substudies found no significant outcome difference between dual and single coils, although using higher rates of DFT testing then currently practiced. We evaluated the temporal trends in implantation rates of single- vs. dual-coil leads and determined the associated adverse clinical outcomes, using a contemporary nation-wide ICD registry. Between July 2010 and March 2015, 6343 consecutive ICD (n = 3998) or CRT-D (n = 2345) implantation patients were prospectively enrolled in the Israeli ICD Registry. A follow-up of at least 1 year of 2285 patients was available for outcome analysis. The primary endpoint was all-cause mortality. Single-coil leads were implanted in 32% of our cohort, 36% among ICD recipients, and 26% among CRT-D recipients. Secondary prevention indication was associated with an increased rate of dual-coil implantation. A significant decline in dual-coil leads with reciprocal incline of single coils was observed, despite low rates of DFT testing (11.6%) during implantation, which also declined from 31 to 2%. In the multivariate Cox model analysis, dual- vs. single-coil lead implantation was not associated with an increased risk of mortality [hazard ratio (HR) = 1.23; P= 0.33], heart failure hospitalization (HR = 1.34; P=0.13), appropriate (HR = 1.25; P= 0.33), or inappropriate ICD therapy (HR = 2.07; P= 0.12). Real-life rates of single-coil lead implantation are rising while adding no additional risk. These results of single-coil safety are reassuring and obtained, despite low and contemporary rates of DFT testing. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  19. [Safety of cardiac pacemakers and implantable cardioverter-defibrillators in magnetic resonance imaging. Assessment of the aggregate function at 1.5 tesla].

    Science.gov (United States)

    Nordbeck, P; Bauer, W R

    2008-03-01

    Magnetic resonance imaging (MRI) is increasingly used in patients, but it is contraindicated in those with cardiac pacemakers (CP) or implantable cardioverter defibrillators (ICD). This study examined circumstances in which potentially life-threatening arrhythmias may be triggered in patients with CP undergoing MRI and whether these problems can be avoided by reprogramming of these devices. Eight CP and seven ICDs were investigated in a phantom at 1.5 tesla (experimental and imaging sequences). A decrease in battery voltage was found in four CP after MRI (indication for elective replacement). Additionally, three showed changes in programming (resets). Analogous changes did not appear in the tested ICDs, but periods of tachycardia were recorded in all types of devices during MRI depending on the pulse sequence employed. MRI-related electromagnetic fields as used in routine MRI can induce severe pacemaker device malfunctions. Device programming approaches are unreliable for prevention of patient hazards, as programming changes or resets are one of the primary malfunctions during MRI.

  20. Educational and psychological interventions to improve outcomes for recipients of implantable cardioverter defibrillators and their families: a scientific statement from the American Heart Association.

    Science.gov (United States)

    Dunbar, Sandra B; Dougherty, Cynthia M; Sears, Samuel F; Carroll, Diane L; Goldstein, Nathan E; Mark, Daniel B; McDaniel, George; Pressler, Susan J; Schron, Eleanor; Wang, Paul; Zeigler, Vicki L

    2012-10-23

    Significant mortality benefits have been documented in recipients of implantable cardioverter defibrillators (ICDs); however, the psychosocial distress created by the underlying arrhythmia and its potential treatments in patients and family members may be underappreciated by clinical care teams. The disentanglement of cardiac disease and device-related concerns is difficult. The majority of ICD patients and families successfully adjust to the ICD, but optimal care pathways may require additional psychosocial attention to all ICD patients and particularly those experiencing psychosocial distress. This state-of-the-science report was developed on the basis of an analysis and critique of existing science to (1) describe the psychological and quality-of-life outcomes after receipt of an ICD and describe related factors, such as patient characteristics; (2) describe the concerns and educational/informational needs of ICD patients and their family members; (3) outline the evidence that supports interventions for improving educational and psychological outcomes for ICD patients; (4) provide recommendations for clinical approaches for improving patient outcomes; and (5) identify priorities for future research in this area. The ultimate goal of this statement is to improve the precision of identification and care of psychosocial distress in ICD patients to maximize the derived benefit of the ICD.

  1. Effect of psycho-educational interventions on quality of life in patients with implantable cardioverter defibrillators: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Kao, Chi-Wen; Chen, Miao-Yi; Chen, Ting-Yu; Lin, Pai-Hui

    2016-09-30

    Implantable cardioverter defibrillators (ICD) were developed for primary and secondary prevention of sudden cardiac death. However, ICD recipients' mortality is significantly predicted by their quality of life (QOL). The aim of this meta-analysis was to evaluate the effects of psycho-educational interventions on QOL in patients with ICDs. We systematically searched PubMed, Medline, Cochrane Library, and CINAHL through April 2015 and references of relevant articles. Studies were reviewed if they met following criteria: (1) randomized controlled trial, (2) participants were adults with an ICD, and (3) data were sufficient to evaluate the effect of psychological or educational interventions on QOL measured by the SF-36 or SF-12. Studies were independently selected and their data were extracted by two reviewers. Study quality was evaluated using a modified Jadad scale. The meta-analysis was conducted using the Cochrane Collaboration's Review Manager Software Package (RevMan 5). Study heterogeneity was assessed by Q statistics and I 2 statistic. Depending on heterogeneity, data were pooled across trials using fixed-effect or random-effect modeling. Seven randomized controlled trials fulfilled the inclusion and exclusion criteria, and included 1017 participants. The psycho-educational interventions improved physical component summary (PCS) scores in the intervention groups more than in control groups (mean difference 2.08, 95 % CI 0.86 to 3.29, p educational interventions improved the physical component, but not the mental component of QOL in patients with ICDs.

  2. Design and Methods for a Pilot Study of a Phone-Delivered, Mindfulness-Based Intervention in Patients with Implantable Cardioverter Defibrillators

    Directory of Open Access Journals (Sweden)

    Elena Salmoirago-Blotcher

    2012-01-01

    Full Text Available Background. Meditation practices are associated with a reduction in adrenergic activity that may benefit patients with severe cardiac arrhythmias. This paper describes the design and methods of a pilot study testing the feasibility of a phone-delivered mindfulness-based intervention (MBI for treatment of anxiety in patients with implantable cardioverter defibrillators (ICDs. Design and Methods. Consecutive, clinically stable outpatients (n=52 will be screened for study eligibility within a month of an ICD-related procedure or ICD shock and will be randomly assigned to MBI or to usual care. MBI patients will receive eight weekly individual phone sessions based on two mindfulness practices (awareness of breath and body scan plus home practice with a CD for 20 minutes daily. Patients assigned to usual care will be offered the standard care planned by the hospital. Assessments will occur at baseline and at the completion of the intervention (between 9 and 12 weeks after randomization. The primary study outcome is feasibility; secondary outcomes include anxiety, mindfulness, and number of administered shocks during the intervention period. Conclusions. If proven feasible and effective, phone-delivered mindfulness-based interventions could improve psychological distress in ICD outpatients with serious cardiovascular conditions.

  3. Identifying patients with less potential to benefit from implantable cardioverter-defibrillator therapy: comparison of the performance of four risk scoring systems.

    Science.gov (United States)

    Kaura, Amit; Sunderland, Nicholas; Kamdar, Ravi; Petzer, Edward; McDonagh, Theresa; Murgatroyd, Francis; Dhillon, Para; Scott, Paul

    2017-08-01

    Patients at high non-sudden cardiac death risk may gain no significant benefit from implantable cardioverter-defibrillator (ICD) therapy. A number of approaches have been proposed to identify these patients, including single clinical markers and more complex scoring systems. The aims of this study were to use the proposed scoring systems to (1) establish how many current ICD recipients may be too high risk to derive significant benefit from ICD therapy and (2) evaluate how well the scoring systems predict short-term mortality in an unselected ICD cohort. We performed a single-centre retrospective observational study of all new ICD implants over 5 years (2009-2013). We used four published scoring systems (Bilchick, Goldenberg, Kramer and Parkash) and serum urea to identify new ICD recipients whose short-term predicted mortality risk was high. We evaluated how well the scoring systems predicted death. Over 5 years, there were 406 new implants (79% male, mean age 70 (60-76), 58% primary prevention). During a follow-up of 936 ± 560 days, 96 patients died. Using the scoring systems, the proportion of ICD recipients predicted to be at high short-term mortality risk were 5.9% (Bilchick), 34.7% (Goldenberg), 7.4% (Kramer), 21.4% (Parkash) and 25% (urea, cut-off of >9.28 mM). All four risk scores predicted mortality (P systems, a significant proportion of current ICD recipients are at high short-term mortality risk. Although all four scoring systems predicted mortality during follow-up, none significantly outperformed serum urea.

  4. Cardiac sympathetic innervation assessed with (123)I-MIBG retains prognostic utility in diabetic patients with severe left ventricular dysfunction evaluated for primary prevention implantable cardioverter-defibrillator.

    Science.gov (United States)

    García-González, P; Fabregat-Andrés, Ó; Cozar-Santiago, P; Sánchez-Jurado, R; Estornell-Erill, J; Valle-Muñoz, A; Quesada-Dorador, A; Payá-Serrano, R; Ferrer-Rebolleda, J; Ridocci-Soriano, F

    2016-01-01

    Scintigraphy with iodine-123-metaiodobenzylguanidine ((123)I-MIBG) is a non-invasive tool for the assessment of cardiac sympathetic innervation (CSI) that has proven to be an independent predictor of survival. Recent studies have shown that diabetic patients with heart failure (HF) have a higher deterioration in CSI. It is unknown if (123)I-MIBG has the same predictive value for diabetic and non-diabetic patients with advanced HF. An analysis is performed to determine whether CSI with (123)I-MIBG retains prognostic utility in diabetic patients with HF, evaluated for a primary prevention implantable cardioverter-defibrillator (ICD). Seventy-eight consecutive HF patients (48 diabetic) evaluated for primary prevention ICD implantation were prospectively enrolled and underwent (123)I-MIBG to assess CSI (heart-to-mediastinum ratio - HMR). A Cox proportional hazards multivariate analysis was used to determine the influence of (123)I-MIBG images for prediction of cardiac events in both diabetic and non-diabetic patients. The primary end-point was a composite of arrhythmic event, cardiac death, or admission due to HF. During a mean follow-up of 19.5 [9.3-29.3] months, the primary end-point occurred in 24 (31%) patients. Late HMR was significantly lower in diabetic patients (1.30 vs. 1.41, p=0.014). Late HMR≤1.30 was an independent predictor of cardiac events in diabetic (hazard ratio 4.53; p=0.012) and non-diabetic patients (hazard ratio 12.31; p=0.023). Diabetic patients with HF evaluated for primary prevention ICD show a higher deterioration in CSI than non-diabetics; nevertheless (123)I-MIBG imaging retained prognostic utility for both diabetic and non-diabetic patients. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  5. Device orientation of a leadless pacemaker and subcutaneous implantable cardioverter-defibrillator in canine and human subjects and the effect on intrabody communication.

    Science.gov (United States)

    Quast, Anne-Floor B E; Tjong, Fleur V Y; Koop, Brendan E; Wilde, Arthur A M; Knops, Reinoud E; Burke, Martin C

    2018-02-14

    The development of communicating modular cardiac rhythm management systems relies on effective intrabody communication between a subcutaneous implantable cardioverter-defibrillator (S-ICD) and a leadless pacemaker (LP), using conducted communication. Communication success is affected by the LP and S-ICD orientation. This study is designed to evaluate the orientation of the LP and S-ICD in canine subjects and measure success and threshold of intrabody communication. To gain more human insights, we will explore device orientation in LP and S-ICD patients. Canine subjects implanted with a prototype S-ICD and LP (both Boston Scientific, MA, USA) with anterior-posterior fluoroscopy images were included in this analysis. For comparison, a retrospective analysis of human S-ICD and LP patients was performed. The angle of the long axis of the LP towards the vertical axis of 0°, and distance between the coil and LP were measured. Twenty-three canine subjects were analysed. Median angle of the LP was 29° and median distance of the S-ICD coil to LP was 0.8 cm. All canine subjects had successful communication. The median communicating threshold was 2.5 V. In the human retrospective analysis, 72 LP patients and 100 S-ICD patients were included. The mean angle of the LP was 56° and the median distance between the S-ICD coil and LP was 4.6 cm. Despite the less favourable LP orientation in canine subjects, all communication attempts were successful. In the human subjects, we observed a greater and in theory more favourable LP angle towards the communication vector. These data suggests suitability of human anatomy for conductive intrabody communication.

  6. The Role of Implantable Cardioverter Defibrillators in Patients Bridged to Transplantation with a Continuous Flow Left Ventricular Assist Device: A Propensity Score Matched Analysis

    Science.gov (United States)

    Clerkin, Kevin J.; Topkara, Veli K.; Mancini, Donna M.; Yuzefpolskaya, Melana; Demmer, Ryan T.; Dizon, Jose M.; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C.; Garan, A. Reshad

    2016-01-01

    Background Implantable cardioverter defibrillators (ICD) provide a significant mortality benefit for appropriately selected patients with advanced heart failure. ICDs are associated with a mortality benefit when used in patients with a pulsatile left ventricular assist device (LVAD). However it is unclear whether patients with a continuous flow LVAD (CF-LVAD) derive the same benefit. This study sought to determine if the presence of an ICD provided a mortality benefit during CFLVAD support as a bridge to transplantation. Methods Patients were identified in the United Network for Organ Sharing (UNOS) registry that underwent LVAD implantation as bridge to transplantation from May 2004 and April 2014, with follow-up through June 2014. The primary outcome was freedom from death while on CF-LVAD support with adjustment for complications requiring UNOS listing status upgrade. Secondary endpoints included freedom from delisting while on CF-LVAD support and incidence of transplantation. Results 2,990 patients composed the study cohort and propensity score matching identified 1,012 patients with similar propensity scores. There was no difference in survival during device support between patients with and without an ICD (Hazard Ratio [HR] 1.20, 95% Confidence Interval [CI] 0.66-2.17, p=0.55). Adjusting for device complications requiring a UNOS listing status upgrade had minimal influence (HR 1.11, 95% CI 0.60-2.05, p=0.74). There was no increased risk of delisting due to being too sick for those with an ICD (HR 1.08, 95% CI 0.63-1.86, p=0.78). Likewise, the probability of transplantation was similar (HR 1.05, 95% CI 0.87-1.27, p=0.62). Conclusions Among patients bridged to transplantation with a CF-LVAD, the presence of an ICD did not reduce mortality. PMID:28089072

  7. The role of implantable cardioverter defibrillators in patients bridged to transplantation with a continuous-flow left ventricular assist device: A propensity score matched analysis.

    Science.gov (United States)

    Clerkin, Kevin J; Topkara, Veli K; Mancini, Donna M; Yuzefpolskaya, Melana; Demmer, Ryan T; Dizon, Jose M; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C; Garan, A Reshad

    2017-06-01

    Implantable cardioverter defibrillators (ICDs) provide a significant mortality benefit for appropriately selected patients with advanced heart failure. ICDs are associated with a mortality benefit when used in patients with a pulsatile left ventricular assist device (LVAD). It is unclear whether patients with a continuous-flow LVAD (CF-LVAD) derive the same benefit. We sought to determine if the presence of an ICD provided a mortality benefit during CF-LVAD support as a bridge to transplantation. Patients were identified in the United Network for Organ Sharing (UNOS) registry who underwent LVAD implantation as bridge to transplantation between May 2004 and April 2014, with follow-up through June 2014. Primary outcome was freedom from death while on CF-LVAD support with adjustment for complications requiring UNOS listing status upgrade. Secondary end-points included freedom from delisting while on CF-LVAD support and incidence of transplantation. The study cohort comprised 2,990 patients, and propensity score matching identified 1,012 patients with similar propensity scores. There was no difference in survival during device support between patients with and without an ICD (hazard ratio [HR] = 1.20; 95% confidence interval [CI], 0.66-2.17; p = 0.55). Adjusting for device complications requiring a UNOS listing status upgrade had minimal influence (HR = 1.11; 95% CI, 0.60-2.05; p = 0.74). There was no increased risk of delisting owing to being too sick for patients with an ICD (HR = 1.08; 95% CI, 0.63-1.86; p = 0.78). Likewise, the probability of transplantation was similar (HR = 1.05; 95% CI, 0.87-1.27; p = 0.62). Among patients bridged to transplantation with a CF-LVAD, the presence of an ICD did not reduce mortality. Copyright © 2017 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  8. Self-reported quality of life predicts mortality 7 years post implant in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Andersen, Christina Maar; Veen, Barbara van; Theuns, Dominic A M J

    2018-01-01

    (SD) age=58 (12) consecutively implanted between 2003 and 2010. Patients completed the SF-36. The eight subscales and the physical and mental component summary scores were used as predictors of mortality 7 years post implant. Results: At 7-year follow-up, 33.7% (132/392) of the patients had died...

  9. [The pacemaker and implantable cardioverter-defibrillator registry of the Italian Association Arrhythmology Cardiac Pacing and cardiac pacing - annual report 2013].

    Science.gov (United States)

    Proclemer, Alessandro; Zecchin, Massimo; D'Onofrio, Antonio; Botto, Giovanni Luca; Rebellato, Luca; Ghidina, Marco; Bianco, Giulia; Bernardelli, Emanuela; Pucher, Elsa; Gregori, Dario

    2014-11-01

    The pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) monitors the main epidemiological data in real-world practice. The survey for the 2013 activity collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers. The Registry collects prospectively national PM and ICD implantation activity on the basis of European cards. PM Registry: data about 25 419 PM implantations were collected (19 134 first implant and 6285 replacements). The number of collaborating centers was 275. Median age of treated patients was 80 years (74 quartile I; 86 quartile III). ECG indications included atrioventricular conduction disorders in 43.6% of first PM implants, sick sinus syndrome in 24.7%, atrial fibrillation plus bradycardia in 12.9%, other in 18.8%. Among atrioventricular conduction defects, third-degree atrioventricular block was the most common type (23.2% of first implants). Use of single-chamber PMs was reported in 27.2% of first implants, of dual-chamber PMs in 62.6%, of PMs with cardiac resynchronization therapy (CRT) in 1.8%, and of single lead atrial-synchronized ventricular stimulation (VDD/R PMs) in 8.4%. ICD Registry: data about 16 519 ICD implantations were collected (11 474 first implants and 5045 replacements). The number of collaborating centers was 430. Median age of treated patients was 71 years (63 quartile I; 77 quartile III). Primary prevention indication was reported in 76% of first implants, secondary prevention in 24.0% (cardiac arrest in 7.8%). A single-chamber ICD was used in 27.2% of first implants, dual-chamber in 35.9% and biventricular in 36.8%. The PM and ICD Registry appears fundamental for monitoring PM and ICD utilization on a large national scale with rigorous examination of demographics and clinical indications. The PM Registry showed stable electrocardiographic

  10. Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator. For the Worldwide Jewel AF Investigators.

    Science.gov (United States)

    Swerdlow, C D; Schsls, W; Dijkman, B; Jung, W; Sheth, N V; Olson, W H; Gunderson, B D

    2000-02-29

    To distinguish prolonged episodes of atrial fibrillation (AF) that require cardioversion from self-terminating episodes that do not, an atrial implantable cardioverter-defibrillator (ICD) must be able to detect AF continuously for extended periods. The ICD should discriminate between atrial tachycardia/flutter (AT), which may be terminated by antitachycardia pacing, and AF, which requires cardioversion. We studied 80 patients with AT/AF and ventricular arrhythmias who were treated with a new atrial/dual-chamber ICD. During a follow-up period lasting 6+/-2 months, we validated spontaneous, device-defined AT/AF episodes by stored electrograms in all patients. In 58 patients, we performed 80 Holter recordings with telemetered atrial electrograms, both to validate the continuous detection of AT/AF and to determine the sensitivity of the detection of AT/AF. Detection was appropriate in 98% of 132 AF episodes and 88% of 190 AT episodes (98% of 128 AT episodes with an atrial cycle length 1 hour, for a total of 2697 hours of continuous detection of AT/AF. During Holter monitoring, the sensitivity of the detection of AT/AF (116 hours) was 100%; the specificity of the detection of non-AT/AF rhythms (1290 hours) was 99.99%. Of 166 appropriate episodes detected as AT, 45% were terminated by antitachycardia pacing. A new ICD detects AT/AF accurately and continuously. Therapy may be programmed for long-duration AT/AF, with a low risk of underdetection. Discrimination of AT from AF permits successful pacing therapy for a significant fraction of AT.

  11. The NO Regular Defibrillation testing In Cardioverter Defibrillator Implantation (NORDIC ICD) trial: concept and design of a randomized, controlled trial of intra-operative defibrillation testing during de novo defibrillator implantation.

    Science.gov (United States)

    Bänsch, Dietmar; Bonnemeier, Hendrik; Brandt, Johan; Bode, Frank; Svendsen, Jesper Hastrup; Felk, Angelika; Hauser, Tino; Wegscheider, Karl

    2015-01-01

    Although defibrillation (DF) testing is still considered a standard procedure during implantable cardioverter-defibrillator (ICD) insertion and has been an essential element of all trials that demonstrated the survival benefit of ICD therapy, there are no large randomized clinical trials demonstrating that DF testing improves clinical outcome and if the outcome would remain the same by omitting DF testing. Between February 2011 and July 2013, we randomly assigned 1077 patients to ICD implantation with (n = 540) or without (n = 537) DF testing. The intra-operative DF testing was standardized across all participating centres. After inducing a fast ventricular tachycardia (VT) with a heart rate ≥240 b.p.m. or ventricular fibrillation (VF) with a low-energy T-wave shock, DF was attempted with an initial 15 J shock. If the shock reversed the VT or VF, DF testing was considered successful and terminated. If unsuccessful, two effective 24 J shocks were administered. If DF was unsuccessful, the system was reconfigured and another DF testing was performed. An ICD shock energy of 40 J had to be programmed in all patients for treatment of spontaneous VT/VF episodes. The primary endpoint was the average efficacy of the first ICD shock for all true VT/VF episodes in each patient during follow-up. The secondary endpoints included the frequency of system revisions, total fluoroscopy, implantation time, procedural serious adverse events, and all-cause, cardiac, and arrhythmic mortality during follow-up. Home Monitoring was used in all patients to continuously monitor the system integrity, device programming and performance. The NO Regular Defibrillation testing In Cardioverter Defibrillator Implantation (NORDIC ICD) trial is one of two large prospective randomized trials assessing the effect of DF testing omission during ICD implantation. NCT01282918. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email

  12. Polymorphisms associated with ventricular tachyarrhythmias: rationale, design, and endpoints of the 'diagnostic data influence on disease management and relation of genomics to ventricular tachyarrhythmias in implantable cardioverter/defibrillator patients (DISCOVERY)' study

    DEFF Research Database (Denmark)

    Wieneke, Heinrich; Spencker, Sebastian; Svendsen, Jesper Hastrup

    2010-01-01

    Implantable cardioverter-defibrillator (ICD) therapy is effective in primary and secondary prevention for patients who are at high risk of sudden cardiac death. However, the current risk stratification of patients who may benefit from this therapy is unsatisfactory. Single nucleotide polymorphism...... pathways will be investigated. As it is a diagnostic study, DISCOVERY will also investigate the impact of long-term device diagnostic data on the management of patients suffering from chronic cardiac disease as well as medical decisions made regarding their treatment.......Implantable cardioverter-defibrillator (ICD) therapy is effective in primary and secondary prevention for patients who are at high risk of sudden cardiac death. However, the current risk stratification of patients who may benefit from this therapy is unsatisfactory. Single nucleotide polymorphisms...... modulate the risk for arrhythmias and sudden cardiac death, and identification of common variants could help to better identify patients at risk. The DISCOVERY study is an interventional, longitudinal, prospective, multi-centre diagnostic study that will enrol 1287 patients in approximately 80 European...

  13. Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

    Energy Technology Data Exchange (ETDEWEB)

    Ghafarian, Pardis [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Aghamiri, S.M.R. [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Ay, Mohammad R. [Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Research Institute for Nuclear Medicine, Tehran (Iran, Islamic Republic of); Rahmim, Arman [Johns Hopkins University, Department of Radiology, Baltimore, MD (United States); Schindler, Thomas H. [Geneva University, Cardiovascular Center, Nuclear Cardiology, Geneva (Switzerland); Ratib, Osman [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Geneva University, Geneva Neuroscience Center, Geneva (Switzerland)

    2011-02-15

    Cardiac PET/CT imaging is often performed in patients with pacemakers and implantable cardioverter defibrillator (ICD) leads. However, metallic implants usually produce artefacts on CT images which might propagate to CT-based attenuation-corrected (CTAC) PET images. The impact of metal artefact reduction (MAR) for CTAC of cardiac PET/CT images in the presence of pacemaker, ICD and ECG leads was investigated using both qualitative and quantitative analysis in phantom and clinical studies. The study included 14 patients with various leads undergoing perfusion and viability examinations using dedicated cardiac PET/CT protocols. The PET data were corrected for attenuation using both artefactual CT images and CT images corrected using the MAR algorithm. The severity and magnitude of metallic artefacts arising from these leads were assessed on both linear attenuation coefficient maps ({mu}-maps) and attenuation-corrected PET images. CT and PET emission data were obtained using an anthropomorphic thorax phantom and a dedicated heart phantom made in-house incorporating pacemaker and ICD leads attached at the right ventricle of the heart. Volume of interest-based analysis and regression plots were performed for regions related to the lead locations. Bull's eye view analysis was also performed on PET images corrected for attenuation with and without the MAR algorithm. In clinical studies, the visual assessment of PET images by experienced physicians and quantitative analysis did not reveal erroneous interpretation of the tracer distribution or significant differences when PET images were corrected for attenuation with and without MAR. In phantom studies, the mean differences between tracer uptake obtained without and with MAR were 10.16{+-}2.1% and 6.86{+-}2.1% in the segments of the heart in the vicinity of metallic ICD or pacemaker leads, and were 4.43{+-}0.5% and 2.98{+-}0.5% in segments far from the leads. Although the MAR algorithm was able to effectively improve

  14. Manual for the psychotherapeutic treatment of acute and post-traumatic stress disorders following multiple shocks from implantable cardioverter defibrillator (ICD).

    Science.gov (United States)

    Jordan, Jochen; Titscher, Georg; Peregrinova, Ludmila; Kirsch, Holger

    2013-01-01

    In view of the increasing number of implanted cardioverter defibrillators (ICD), the number of people suffering from so-called "multiple ICD shocks" is also increasing. The delivery of more than five shocks (appropriate or inappropriate) in 12 months or three or more shocks (so called multiple shocks) in a short time period (24 hours) leads to an increasing number of patients suffering from severe psychological distress (anxiety disorder, panic disorder, adjustment disorder, post-traumatic stress disorder). Untreated persons show chronic disease processes and a low rate of spontaneous remission and have an increased morbidity and mortality. Few papers have been published concerning the psychotherapeutic treatment for these patients. The aim of this study is to develop a psychotherapeutic treatment for patients with a post-traumatic stress disorder or adjustment disorder after multiple ICD shocks. Explorative feasibility study: Treatment of 22 patients as a natural design without randomisation and without control group. The period of recruitment was three years, from March 2007 to March 2010. The study consisted of two phases: in the first phase (pilot study) we tested different components and dosages of psychotherapeutic treatments. The final intervention programme is presented in this paper. In the second phase (follow-up study) we assessed the residual post-traumatic stress symptoms in these ICD patients. The time between treatment and follow-up measurement was 12 to 30 months. Thirty-one patients were assigned to the Department of Psychocardiology after multiple shocks. The sample consisted of 22 patients who had a post-traumatic stress disorder or an adjustment disorder and were willing and able to participate. They were invited for psychological treatment. 18 of them could be included into the follow-up study. After the clinical assessment at the beginning and at the end of the inpatient treatment a post-treatment assessment with questionnaires followed. In

  15. Implantable Cardioverter-Defibrillators in Patients With a Continuous-Flow Left Ventricular Assist Device: An Analysis of the INTERMACS Registry.

    Science.gov (United States)

    Clerkin, Kevin J; Topkara, Veli K; Demmer, Ryan T; Dizon, Jose M; Yuzefpolskaya, Melana; Fried, Justin A; Mai, Xingchen; Mancini, Donna M; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C; Garan, A Reshad

    2017-12-01

    This study sought to determine if the presence of implantable cardioverter-defibrillators (ICD) provided a mortality benefit during continuous-flow left ventricular assist device (LVAD) support. An ICD decreases mortality in selected patients with advanced heart failure and have been associated with reduced mortality in patients with pulsatile LVAD. However, it is unclear whether that benefit extends to patients with a contemporary continuous-flow LVAD. Propensity score matching was used to generate a cohort of patients with similar baseline characteristics. The primary outcome was freedom from death during LVAD support. Secondary endpoints included freedom from unexpected death, likelihood of transplantation and recovery, and adverse events. Among 16,384 eligible patients in the Interagency Registry for Mechanically Assisted Circulatory Support registry, 2,209 patients with an ICD and 2,209 patients without one had similar propensity scores and were included. The presence of an ICD was associated with an increased mortality risk (hazard ratio: 1.20; 95% confidence interval [CI]: 1.04 to 1.39; p = 0.013) and an increased risk of unexpected death during device support (HR: 1.33; 95% CI: 1.03 to 1.71; p = 0.03). Patients with an ICD were more likely to undergo transplantation (HR: 1.16; 95% CI: 0.99 to 1.35; p = 0.06) and less likely to have LVAD explant for recovery (HR: 0.53, 95% CI: 0.29 to 0.98; p = 0.04). Patients with an ICD had a higher rate of treated ventricular arrhythmias (rate ratio: 1.27; 95% CI: 1.10 to 1.48; p = 0.001) and rehospitalization (rate ratio: 1.08; 95% CI: 1.04 to 1.12; p < 0.0001), but rates of hemorrhagic stroke were similar (rate ratio: 1.01; 95% CI: 0.81 to 1.26; p = 0.98). Among patients with a continuous flow LVAD, the presence of an ICD was not associated with reduced mortality. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Relation of symptomatic heart failure and psychological status to persistent depression in patients with implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Hoogwegt, Madelein T; Jordaens, Luc

    2011-01-01

    . We examined the prevalence and correlates of persistent depression using an intraindividual approach. Consecutive patients who had undergone ICD implantation (n = 386; 79.3% men) completed a set of validated questionnaires, including the Hospital Anxiety and Depression Scale (HADS), at baseline and 3...... months after implantation. Information on ICD therapies was obtained by device interrogation. At 3 months after implantation, 52 (14%) of the 386 patients had persistent depression (HADS cutoff ≥8 before and 3 months after implantation). Heart failure (odds ratio [OR] 2.29; 95% confidence interval [CI] 1.......71), diuretics (OR 2.41; 95% CI 1.26 to 4.61), and psychotropic medication (OR 3.58; 95% CI 1.86 to 6.90) were all significant univariate correlates of persistent depression at 3 months. No effect was found for ICD shock during follow-up (OR 1.59; 95% CI 0.57 to 4.41). In adjusted analysis, New York Heart...

  17. Mechanical dispersion and global longitudinal strain by speckle tracking echocardiography: Predictors of appropriate implantable cardioverter defibrillator therapy in hypertrophic cardiomyopathy.

    Science.gov (United States)

    Candan, Ozkan; Gecmen, Cetin; Bayam, Emrah; Guner, Ahmet; Celik, Mehmet; Doğan, Cem

    2017-06-01

    In this study, we investigated whether mechanical dispersion which reflects electrical abnormality and other echocardiographic and clinic parameters predict appropriate ICD shock in patients undergone ICD implantation for hypertrophic cardiomyopathy. Sixty-three patients who received ICD implantation for primary or secondary prevention were included in the study. Patients' clinical, electrocardiographic, 2D classic, and speckle tracking echocardiographic data were collected. Mechanical dispersion was defined as the standard deviation of time to peak negative strain in 18 left ventricular segments. Appropriate ICD therapy was defined as cardioversion or defibrillation due to ventricular tachycardia or fibrillation. Patients were divided into two groups as occurrence or the absence of appropriate ICD therapy. A total of 17 (26.9%) patients were observed to have an appropriate ICD therapy during follow-up periods. In patients who performed appropriate ICD therapy, a larger left atrial volume index, higher sudden cardiac death (SCD)-Risk Score, longer mechanical dispersion, and decreased global longitudinal peak strain (GLPS) were observed. In multivariate logistic regression analysis, including (GLPS, mechanical dispersion, LAVi, and SCD-Risk Score) was used to determine independent predictors of occurrence of appropriate ICD therapy during the follow-up. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be independent predictors of occurrence of appropriate ICD therapy. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be predictive for appropriate ICD therapy in patients receiving ICD implantation. Readily measurable mechanical dispersion and GLPS could be helpful to distinguish patients at high risk who could optimally benefit from ICD therapy. © 2017, Wiley Periodicals, Inc.

  18. The impact of co-morbidity burden on appropriate implantable cardioverter defibrillator therapy and all-cause mortality

    DEFF Research Database (Denmark)

    Ruwald, Anne Christine; Vinther, Michael; Gislason, Gunnar H

    2017-01-01

    -ICD indication-related co-morbidities including atrial fibrillation, diabetes, chronic obstructive pulmonary disease, chronic renal disease, liver disease, cancer, chronic psychiatric disease, and peripheral and/or cerebrovascular disease, and divided into four groups (co-morbidity burden 0, 1, 2, and ≥3......). Through Cox models, we assessed the impact of co-morbidity burden on appropriate ICD therapy and mortality. Increasing co-morbidity burden was not associated with increased risk of appropriate therapy, irrespective of implant indication [all hazard ratios (HRs) 1.0-1.4, P = NS]. Using no co...

  19. Sex and Race/Ethnicity Differences in Implantable Cardioverter-Defibrillator Counseling and Use Among Patients Hospitalized With Heart Failure: Findings from the Get With The Guidelines-Heart Failure Program.

    Science.gov (United States)

    Hess, Paul L; Hernandez, Adrian F; Bhatt, Deepak L; Hellkamp, Anne S; Yancy, Clyde W; Schwamm, Lee H; Peterson, Eric D; Schulte, Phillip J; Fonarow, Gregg C; Al-Khatib, Sana M

    2016-08-16

    Previous studies have found that women and black patients eligible for a primary prevention implantable cardioverter-defibrillator (ICD) are less likely than men or white patients to receive one. We performed an observational analysis of the Get With The Guidelines-Heart Failure Program from January 1, 2011, to March 21, 2014. Patients admitted with heart failure and an ejection fraction ≤35% without an ICD were included. Rates of ICD counseling among eligible patients and ICD receipt among counseled patients were examined by sex and race/ethnicity. Among 21 059 patients from 236 sites, 4755 (22.6%) received predischarge ICD counseling. Women were counseled less frequently than men (19.3% versus 24.6%, Prace/ethnic group 14.4% versus white 24.3%, Pdifferences by race and ethnicity persisted. © 2016 American Heart Association, Inc.

  20. Clinical safety of an MRI conditional implantable cardioverter defibrillator system: A prospective Monocenter ICD-Magnetic resonance Imaging feasibility study (MIMI).

    Science.gov (United States)

    Kypta, Alexander; Blessberger, Hermann; Hoenig, Simon; Saleh, Karim; Lambert, Thomas; Kammler, Juergen; Fellner, Franz; Lichtenauer, Michael; Steinwender, Clemens

    2016-03-01

    The aim of this study was to evaluate the safety and efficacy of the Lumax 740(®) Implantable Cardioverter Defibrillator (ICD) system in patients undergoing a defined 1.5 Tesla (T) MRI. Between November 2013 and April 2014, eighteen patients (age range, 41-78 years; mean age, 64 years) implanted with a Lumax 740(®) ICD system for at least 6 weeks before an MRI were enrolled into this single-center feasibility study. The local ethics committee approved the study before patients gave written informed consent. Patients underwent defined MRI 1.5T of the brain and lower lumbar spine with three safety follow-up evaluations obtained during the 3-month study period. Data were analyzed descriptively. Study endpoints were the absence of either MRI and pacing system related serious adverse device effects (SADE), or of a ventricular pacing threshold increase >0.5V, or of an R-wave amplitude attenuation battery status. Sixteen patients completed the MRI and the follow-up period. As no SADE occurred, the SADE free rate was 100%. Freedom from ventricular pacing threshold increase was 100% (16/16; 95%CI: 82.9%; 100.0%). There were no significant differences between baseline and follow-up measurements of sensing amplitudes (-0.58 ± 2.07 mV, P = 0.239, -0.41 ± 1.04 mV, P = 0.133, and -0.25 ± 1.36 mV, P = 0.724, for immediately after, 1 month and 3 months after MRI scan, respectively) and pacing thresholds (-0.047 ± 0.18 V, P = 0.317, -0.019 ± 0.11 V, P = 0.490, and 0.075 ± 0.19 V, P = 0.070, for immediately after, 1 month and 3 months after MRI scan, respectively). Lead impedances after the MRI scan were significantly lower as compared with baseline values (-22.8 ± 21.69 Ω, P = 0.001, -21.62 ± 39.71 Ω, P = 0.040, and -33.68 ± 57.73 Ω, P = 0.018, for immediately after, 1 month and 3 months after MRI scan, respectively). MRI scans in patients with MRI conditional ICD system (Lumax 740(

  1. A Pregnancy with Severe Hypertrophic Obstructive Cardiomyopathy after Surgery for an Implantable Cardioverter Defibrillator: A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Takashi Mitsui

    2016-01-01

    Full Text Available Hypertrophic obstructive cardiomyopathy (HOCM is cardiac hypertrophy of ventricular myocardium with left ventricular outflow tract obstruction. We report a pregnancy with HOCM after defibrillator implantation surgery. The patient was a 33-year-old nulligravida and was categorized as New York Heart Association class II. Her brain natriuretic peptide (BNP level was 724.6 pg/dL at preconception. She received careful pregnancy management. However, because frequent uterine contractions were observed at 25 weeks and 6 days of pregnancy, she was hospitalized, and magnesium sulfate was started as a tocolytic agent. At 27 weeks and 5 days of pregnancy, she had respiratory discomfort and orthopnea with a sudden decrease in peripheral oxygen saturation. Cardiac ultrasonography showed a worsened condition of HOCM and her BNP level was 1418.0 pg/mL. We performed an emergent cesarean section and she delivered a boy weighing 999 g. The Apgar score was 8 and 9 points at 1 and 5 minutes, respectively. The mother’s heart failure quickly improved after birth and she was discharged at 10 days postoperatively. Fluctuations in circulatory dynamics during pregnancy may sometimes exacerbate heart disease. Therefore, the risks should be fully explained and careful assessment of cardiac function should be performed during pregnancy in patients with severe HOCM.

  2. Development and evaluation of the EOL-ICDQ as a measure of experiences, attitudes and knowledge in end-of-life in patients living with an implantable cardioverter defibrillator.

    Science.gov (United States)

    Thylén, Ingela; Wenemark, Marika; Fluur, Christina; Strömberg, Anna; Bolse, Kärstin; Årestedt, Kristofer

    2014-04-01

    Due to extended indications and resynchronization therapy, many implantable cardioverter defibrillator (ICD) recipients will experience progressive co-morbid conditions and will be more likely to die of causes other than cardiac death. It is therefore important to elucidate the ICD patients' preferences when nearing end-of-life. Instead of avoiding the subject of end-of-life, a validated questionnaire may be helpful to explore patients' experiences and attitudes about end-of-life concerns and to assess knowledge of the function of the ICD in end-of-life. Validated instruments assessing patients' perspective concerning end-of-life issues are scarce. The purpose of this study was to develop and evaluate respondent satisfaction and measurement properties of the 'Experiences, Attitudes and Knowledge of End-of-Life Issues in Implantable Cardioverter Defibrillator Patients' Questionnaire' (EOL-ICDQ). The instrument was tested for validity, respondent satisfaction, and for homogeneity and stability in the Swedish language. An English version of the EOL-ICDQ was validated, but has not yet been pilot tested. The final instrument contained three domains, which were clustered into 39 items measuring: experiences (10 items), attitudes (18 items), and knowledge (11 items) of end-of-life concerns in ICD patients. In addition, the questionnaire also contained items on socio-demographic background (six items) and ICD-specific background (eight items). The validity and reliability properties were considered sufficient. The EOL-ICDQ has the potential to be used in clinical practice and future research. Further studies are needed using this instrument in an Anglo-Saxon context with a sample of English-speaking ICD recipients.

  3. Subcutaneous Implantable Cardioverter-Defibrillator

    Science.gov (United States)

    ... discriminator functions and lacks antitachycardia pacing. Expanded Programmability Programming that allows lower shock energies and the ability ... 2014 American Heart Association, Inc. References 1. ↵ Weiss R , Knight BP , Gold MR , Leon AR , Herre JM , ...

  4. Increased anxiety in partners of patients with a cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; VAN DEN Berg, Martha; Erdman, Ruud A M

    2009-01-01

    The partner of the implantable cardioverter-defibrillator (ICD) patient serves as an important source of support for the patient, which may be hampered if the partner experiences increased distress. We examined (1) potential differences in anxiety and depressive symptoms in ICD patients compared...

  5. New horizon for infection prevention technology and implantable device

    Directory of Open Access Journals (Sweden)

    Yusuke Kondo, MD, PhD

    2016-08-01

    Full Text Available There has been a significant increase in the number of patients receiving cardiovascular implantable electronic devices (CIED over the last two decades. CIED infection represents a serious complication after CIED implantation and is associated with significant morbidity and mortality. Recently, newly advanced technologies have offered attractive and suitable therapeutic alternatives. Notably, the leadless pacemaker and anti-bacterial envelope decrease the potential risk of CIED infection and the resulting mortality, when it does occur. A completely subcutaneous implantable cardioverter defibrillator is also an alternative to the transvenous implantable cardioverter defibrillator (ICD, as it does not require implantation of any transvenous or epicardial leads. Among the patients who require ICD removal and subsequent antibiotics secondary to infection, the wearable cardioverter defibrillator represents an alternative approach to inpatient monitoring for the prevention of sudden cardiac death. In this review paper, we aimed to introduce the advanced technologies and devices for prevention of CIED infection.

  6. Diagnostic Value of MRI in Patients With Implanted Pacemakers and Implantable Cardioverter-Defibrillators Across a Cross Population: Does the Benefit Justify the Risk? A Proof of Concept Study.

    Science.gov (United States)

    Samar, Huma; Yamrozik, June A; Williams, Ronald B; Doyle, Mark; Shah, Moneal; Bonnet, Christopher A; Biederman, Robert W W

    2017-09-01

    The objective of this study was to assess the diagnostic usefulness of thoracic and nonthoracic magnetic resonance imaging (MRI) imaging in patients with implantable cardiac devices (permanent pacemaker or implantable cardioverter-defibrillators [ICDs]) to determine if there was a substantial benefit to patients with regard to diagnosis and/or management. MRI is infrequently performed on patients with conventional pacemakers or ICDs. Multiple studies have documented the safety of MRI scans in patients with implanted devices, yet the diagnostic value of this approach has not been established. Evaluation data were acquired in 136 patients with implanted cardiac devices who underwent MRIs during a 10-year period at a single institution. Specific criteria were followed for all patients to objectively define if the diagnosis by MRI enhanced patient care; 4 questions were answered after scan interpretation by both MRI technologists and MRI physicians who performed the scan. 1) Did the primary diagnosis change? 2) Did the MRI provide additional information to the existing diagnosis? 3) Was the pre-MRI (tentative) diagnosis confirmed? 4) Did patient management change? If "Yes" was answered to any of the preceding questions, the MRI scan was considered to be of value to patient diagnosis and/or therapy. In 97% (n = 132) of patients, MR added value to patient diagnosis and management. In 49% (n = 67) of patients, MRI added additional valuable information to the primary diagnosis, and in 30% (n = 41) of patients, MRI changed the principle diagnosis and subsequent management of the patient. No safety issues were encountered, and no adverse effects of undergoing the MRI scan were noted in any patient. MRI in patients with implanted pacemakers and defibrillators added value to patient diagnosis and management, which justified the risk of the procedure. Published by Elsevier Inc.

  7. Wearable cardioverter defibrillator: A life vest till the life boat (ICD arrives

    Directory of Open Access Journals (Sweden)

    Johnson Francis

    2014-01-01

    Full Text Available It is well established that implantable cardioverter defibrillator (ICD is a life saving device ensuring protection against life threatening ventricular arrhythmias. But there are certain situations like a recent myocardial infarction where the standard guidelines do not recommend the implantation of an ICD while the patient can still be at a risk of demise due to a life threatening ventricular arrhythmia. There could also be a temporary indication for protection while explanting an infected ICD system. The wearable cardioverter defibrillator (WCD is a device which comes to the rescue in such situations. In this brief review, we discuss the historical aspects of the development of a WCD, technical aspects as well as the clinical trial data and real world scenario of its use.

  8. MR Imaging in patients with cardiac pacemakers and implantable cardioverter defibrillators. Consensus paper of the German Cardiac Society and the German Roentgen Society; MR-Untersuchungen bei Patienten mit Herzschrittmachern und implantierbaren Kardioverter-Defibrillatoren. Konsensuspapier der Deutschen Gesellschaft fuer Kardiologie (DGK) und der Deutschen Roentgengesellschaft (DRG)

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Torsten [DRK Krankenhaus, Neuwied (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Bauer, Wolfgang [Deutsches Zentrum fuer Herzinsuffizienz Univ. Wuerzburg (Germany). Med. Klinik und Poliklinik I Univ. Klinikum Wuerzburg; Fischbach, Katharina [Universitaetsklinikum Magdeburg (Germany). Klinik fuer Radiologie und Nuklearmedizin; and others

    2017-03-15

    This joint consensus paper of the German Roentgen Society and the German Cardiac Society provides physical and electrophysiological background information and specific recommendations for the procedural management of patients with cardiac pacemakers (PM) and implantable cardioverter defibrillators (ICD) undergoing magnetic resonance (MR) imaging. The paper outlines the responsibilities of radiologists and cardiologists regarding patient education, indications, and monitoring with modification of MR sequences and PM/ICD reprogramming strategies being discussed in particular. The aim is to optimize patient safety and to improve legal clarity in order to facilitate the access of SM/ICD patients to MR imaging.

  9. Rapid-rate nonsustained ventricular tachycardia found on implantable cardioverter-defibrillator interrogation: relationship to outcomes in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial).

    Science.gov (United States)

    Chen, Jay; Johnson, George; Hellkamp, Anne S; Anderson, Jill; Mark, Daniel B; Lee, Kerry L; Bardy, Gust H; Poole, Jeanne E

    2013-05-28

    The aim of this study was to examine rapid-rate nonsustained ventricular tachycardia (RR-NSVT) during routine implantable cardioverter-defibrillator (ICD) evaluation in patients with heart failure and its relationship to outcomes. The clinical implications of RR-NSVT identified during routine ICD interrogation are unclear. In this study, the occurrence of RR-NSVT and its association with ICD shocks and mortality in SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial) were examined. The 811 patients who received ICDs in SCD-HeFT constituted the study population. The occurrence of RR-NSVT and its association with ICD shocks and mortality in SCD-HeFT were examined. RR-NSVT was documented on ICD interrogation in 186 of 811 patients (22.9%). The mean duration of RR-NSVT was 26.4 ± 9.1 beats (7.5 ± 2.6 s), with a mean cycle length of 259 ± 32 ms. Polymorphic RR-NSVT accounted for 56% of episodes. Compared with patients without RR-NSVT, those with RR-NSVT were less likely to be taking beta-blockers, statins, or aspirin at enrollment. After adjusting for other known predictors of mortality in SCD-HeFT, RR-NSVT was independently associated with appropriate ICD shocks (hazard ratio: 4.25; 95% confidence interval: 2.94 to 6.14; p interrogation should be considered an important clinical event. RR-NSVT during ICD interrogation is associated with appropriate ICD shocks and all-cause mortality. The clinical evaluation of patients with RR-NSVT should include intensification of medical therapy, particularly beta-blockers, or other appropriate clinical interventions. (Sudden Cardiac Death in Heart Failure Trial [SCD-HeFT]; NCT00000609). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. The natural history of new-onset heart failure with a severely depressed left ventricular ejection fraction: implications for timing of implantable cardioverter-defibrillator implantation.

    Science.gov (United States)

    Teeter, William A; Thibodeau, Jennifer T; Rao, Krishnasree; Brickner, M Elizabeth; Toto, Kathleen H; Nelson, Lauren L; Mishkin, Joseph D; Ayers, Colby R; Miller, Justin G; Mammen, Pradeep P A; Patel, Parag C; Markham, David W; Drazner, Mark H

    2012-09-01

    Guidelines recommend that patients with new-onset systolic heart failure (HF) receive a trial of medical therapy before an implantable cardiac defibrillator (ICD). This strategy allows for improvement of left ventricular ejection fraction (LVEF), thereby avoiding an ICD, but exposes patients to risk of potentially preventable sudden cardiac death during the trial of medical therapy. We reviewed a consecutive series of patients with HF of <6 months duration with a severely depressed LVEF (<30%) evaluated in a HF clinic (N = 224). The ICD implantation was delayed with plans to reassess LVEF approximately 6 months after optimization of β-blockers. Mortality was ascertained by the National Death Index. Follow-up echocardiograms were performed in 115 of the 224 subjects. Of these, 50 (43%) had mildly depressed or normal LVEF at follow-up ("LVEF recovery") such that an ICD was no longer indicated. In a conservative sensitivity analysis (using the entire study cohort, whether or not a follow-up echocardiogram was obtained, as the denominator), 22% of subjects had LVEF recovery. Mortality at 6, 12, and 18 months in the entire cohort was 2.3%, 4.5%, and 6.8%, respectively. Of 87 patients who tolerated target doses of β-blockers, only 1 (1.1%) died during the first 18 months. Patients with new-onset systolic HF have both a good chance of LVEF recovery and low 6-month mortality. Achievement of target β-blocker dose identifies a very low-risk population. These data support delaying ICD implantation for a trial of medical therapy. Copyright © 2012 Mosby, Inc. All rights reserved.

  11. Physical activity in primary versus secondary prevention indication implantable cardioverter defibrillator recipients 6-12 months after implantation - a cross-sectional study with register follow up

    DEFF Research Database (Denmark)

    Berg, S. K.; Thygesen, L. C.; Svendsen, J. H.

    2015-01-01

    OBJECTIVE: To describe (i) physical activity status among ICD patients according to the indication for ICD implant compared to international guidelines and compared to a matched normal population in order to detect potentials for improved physical outcomes, (ii) patients' beliefs regarding...... and participation in physical exercise by ICD indication, (iii) factors predicting low physical activity, and (iv) physical activity as a predictor of mortality. DESIGN: National survey with register follow-up. Comparisons were made to a matched healthy reference population and patients were followed in registers...... MEASURES: Questions regarding physical activity and the IPAQ questionnaire were used to assess physical activity. RESULTS: The response rate was 71.7%. Mean age 65.5 years with 82% males. 37% participated in a rehabilitation programme. 21 % were sedentary compared to 8 % in the reference population (p

  12. Antibacterial Envelope Is Associated With Low Infection Rates After Implantable Cardioverter-Defibrillator and Cardiac Resynchronization Therapy Device Replacement: Results of the Citadel and Centurion Studies.

    Science.gov (United States)

    Henrikson, Charles A; Sohail, M Rizwan; Acosta, Helbert; Johnson, Eric E; Rosenthal, Lawrence; Pachulski, Roman; Dan, Dan; Paladino, Walter; Khairallah, Farhat S; Gleed, Kent; Hanna, Ibrahim; Cheng, Alan; Lexcen, Daniel R; Simons, Grant R

    2017-10-01

    This study sought to determine whether the nonabsorbable TYRX Antibacterial Envelope (TYRX) reduces major cardiovascular implantable electronic device (CIED) infections 12 months after implant. TYRX is a monofilament polypropylene mesh impregnated with minocycline and rifampin specifically designed to hold a CIED in place and elute antimicrobials over time. There are limited data on its ability to reduce CIED infections. We prospectively enrolled patients who underwent generator replacement with an implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy device (CRT), treated with TYRX. The primary endpoints were major CIED infection and CIED mechanical complications. Given the differences in infection rates among ICD and CRT patients, 3 different control populations were used: a published benchmark rate for ICD patients, and both site-matched and comorbidity-matched controls groups for CRT patients. Overall, a major CIED infection occurred in 5 of 1,129 patients treated with TYRX (0.4%; 95% confidence interval: 0.0% to 0.9%), significantly lower than the 12-month benchmark rate of 2.2% (p = 0.0023). Among the TYRX-treated CRT cohort, the major CIED infection rate was 0.7% compared with an infection rate of 1.0% and 1.3% (p = 0.38 and p = 0.02) in site-matched and comorbidity-matched control groups, respectively. Among the ICD group, the 12-month infection rate was 0.2% compared with the published benchmark of 2.2% (p = 0.0052). The most common CIED mechanical complication in study patients was pocket hematoma, which occurred in 18 of the 1,129 patients (1.6%; 95% confidence interval: 0.8 to 2.5), which is comparable with a published rate of 1.6%. Use of TYRX was associated with a lower major CIED infection rate. (TYRX™ Envelope for Prevention of Infection Following Replacement With a CRT or ICD; [Centurion]; NCT01043861/NCT01043705). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  13. Frequency of "Pocket" Hematoma in Patients Receiving Vitamin K Antagonist and Antiplatelet Therapy at the Time of Pacemaker or Cardioverter Defibrillator Implantation (from the POCKET Study).

    Science.gov (United States)

    Malagù, Michele; Trevisan, Filippo; Scalone, Antonella; Marcantoni, Lina; Sammarco, Giuseppe; Bertini, Matteo

    2017-04-01

    In patients undergoing cardiac device implantation, anticoagulant and antiplatelet therapy are associated with an increased risk of pocket hematoma. In case of vitamin K antagonist therapy, a strategy of continued warfarin with no heparin bridge showed a reduction of pocket hematoma. Evidence regarding antiplatelet therapy management is limited. This is a single-center observational study which reflects our systematic approach to the problem. In 2012, we proposed an improved management protocol for anticoagulant and antiplatelet therapy (no-bridge protocol) based on individual thromboembolic risk stratification, noninterruption of oral anticoagulation, no bridge with heparin and elastic adherence compression bandage. The primary end point was the incidence of clinically significant pocket hematoma in the first 30 days after implantation. A total of 1,035 patients were enrolled, of whom 522 received the standard management and 513 the new protocol. The primary end point occurred in 34 patients of the standard management group and 8 patients of the no-bridge protocol group (6.5% vs 1.6%, p hematoma (relative risk [RR] 3.48, 95% confidence interval [CI] 1.55 to 7.83 and RR 2.43, 95% CI 1.25 to 4.76, respectively), whereas the no-bridge protocol was associated with a reduction of pocket hematoma (RR 0.33, 95% CI 0.14 to 0.76). New anticoagulant and antiplatelet therapy management protocol was associated with a reduced incidence of clinically significant pocket hematomas, thromboembolic events, pocket infections, and lead dislodgements. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Living with Your Implantable Cardioverter Defibrillator (ICD)

    Science.gov (United States)

    ... and Live Our Interactive Cardiovascular Library has detailed animations and illustrations to help you learn about conditions, treatments and procedures related to heart disease and stroke. Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  15. A patient with severely reduced LV function and electrical storm saved by wearable cardioverter-defibrillator: a case report.

    Science.gov (United States)

    Strauss, Margit; Kouraki, Kleopatra; Skarlos, Alexandros; Zahn, Ralf; Kleemann, Thomas

    2013-06-01

    The wearable cardioverter-defibrillator (WCD) is indicated in patients who are considered to be at temporarily high risk for sudden cardiac death (SCD), when an implantable defibrillator is not yet clearly indicated. We report the case of a 41-year-old patient with a newly diagnosed severely reduced left ventricular (LV) function for suspected myocarditis and repeated nonsustained ventricular tachycardia (VT). This patient was supplied with a WCD who came back to the hospital 4 weeks after discharge with an electrical storm and adequate discharge of the WCD. After application of amiodarone, no further arrhythmias were detected during intrahospital course. For further risk stratification, we performed a magnetic field imaging (MFI), that was reported to be useful in risk assessment of SCD in patients with ischemic cardiomyopathy. This measurement showed a normal result, but we decided to give an implantable cardioverter-defibrillator (ICD) to the patient. During a follow-up of 1 year, no further arrhythmias occurred. With this case, we report the efficacy of a WCD, which is a novel tool in patients at temporarily high risk of SCD and we report a novel method of risk stratification in patients with a high risk of SCD.

  16. Incidência de choques e qualidade de vida em jovens com cardioversor-desfibrilador implantável Incidence of shock and quality of life in young patients with implantable cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Roberto Costa

    2007-03-01

    Full Text Available OBJETIVOS: Avaliar a incidência e a causa de choques de CDI em crianças e adolescentes e sua repercussão na qualidade de vida (QV. MÉTODOS: De março/1997 a fevereiro/2006, 29 pacientes (15,7±5,4 anos foram submetidos a implante de CDI. Parada cardiorrespiratória recuperada (41,5%, taquicardia ventricular sustentada (27,6% e profilaxia primária de morte súbita cardíaca (30,9% motivaram os implantes. O número de terapias foi avaliado por entrevista e pela telemetria dos CDI. A QV foi avaliada pela aplicação do questionário SF-36 e comparada à de indivíduos saudáveis. Empregou-se o método de Kaplan-Meier para análise da sobrevida livre de choques. RESULTADOS: Após 2,6±1,8 anos de seguimento, 8 (27,6% pacientes receberam 141 choques apropriados em razão de TV polimórfica (6 ou FV (2, e 11 (37,9% sofreram 152 choques inapropriados em razão de taquiarritmias supraventriculares (8 ou oversensing (3. A expectativa de sobrevida livre de choques apropriados foi de 74,2%±9,0 após um ano, e de 66,7%±10,7 após três anos. Observou-se diminuição da QV nos aspectos físicos (61,7±28,7, na vitalidade (64,7±19,1, na saúde mental (65,9±22,7 e nos aspectos emocionais (66,7±38,5. Medo e preocupações relacionados ao CDI foram referidos por todos os pacientes. CONCLUSÃO: A despeito da grande eficácia dessa terapêutica, a incidência elevada de choques interferiu na QV e na adaptação ao dispositivo.OBJECTIVES: To analyze the incidence and causes of ICD therapies in children and young adults and verify their impact on the quality of life (QoL. METHODS: From March/1977 to February/2006, 29 patients (15.7±5.4 years old were submitted to ICD implants. Aborted cardiac arrest (41.5%, sustained ventricular tachycardia (27.6% and primary prophylaxis of sudden cardiac death (30.9% indicated device therapy. The number of therapies was evaluated by interviewing patients and by ICD diagnostic data. The SF-36 questionnaire was used to

  17. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  18. Short- and long-term performance of a tripolar down-sized single lead for implantable cardioverter defibrillator treatment: a randomized prospective European multicenter study. European Endotak DSP Investigator Group.

    Science.gov (United States)

    Sandstedt, B; Kennergren, C; Schaumann, A; Herse, B; Neuzner, J

    1998-11-01

    A new, thinner (10 Fr) and more flexible, single-pass transvenous endocardial ICD lead, Endotak DSP, was compared with a conventional lead, Endotak C, as a control in a prospective randomized multicenter study in combination with a nonactive can ICD. A total of 123 patients were enrolled, 55 of whom received a down-sized DSP lead. Lead-alone configuration was successfully implanted in 95% of the DSP patients vs 88% in the control group. The mean defibrillation threshold (DFT) was determined by means of a step-down protocol, and was identical in the two groups, 10.5 +/- 4.8 J in the DSP group versus 10.5 +/- 4.8 J in the control group. At implantation, the DSP mean pacing threshold was lower, 0.51 +/- 0.18 V versus 0.62 +/- 0.35 V (p < 0.05) in the control group, and the mean pacing impedance higher, 594 +/- 110 omega vs 523 +/- 135 omega (p < 0.05). During the follow-up period, the statistically significant difference in thresholds disappeared, while the difference in impedance remained. Tachyarrhythmia treatment by shock or antitachycardia pacing (ATP) was delivered in 53% and 41%, respectively, of the patients with a 100% success rate. In the DSP group, all 28 episodes of polymorphic ventricular tachycardia or ventricular fibrillation were converted by the first shock as compared to 57 of 69 episodes (83%) in the control group (p < 0.05). Monomorphic ventricular tachycardias were terminated by ATP alone in 96% versus 94%. Lead related problems were minor and observed in 5% and 7%, respectively. In summary, both leads were safe and efficacious in the detection and treatment of ventricular tachyarrhythmias. There were no differences between the DSP and control groups regarding short- or long-term lead related complications.

  19. Association of psychiatric history and type D personality with symptoms of anxiety, depression, and health status prior to ICD implantation

    DEFF Research Database (Denmark)

    Starrenburg, Annemieke H; Kraaier, Karin; Pedersen, Susanne S.

    2013-01-01

    Personality factors and psychiatric history may help explain individual differences in risk of psychological morbidity and poor health outcomes in patients with an implantable cardioverter defibrillator (ICD).......Personality factors and psychiatric history may help explain individual differences in risk of psychological morbidity and poor health outcomes in patients with an implantable cardioverter defibrillator (ICD)....

  20. An eight-year prospective controlled study about the safety and diagnostic value of cardiac and non-cardiac 1.5-T MRI in patients with a conventional pacemaker or a conventional implantable cardioverter defibrillator.

    Science.gov (United States)

    Lupo, Pierpaolo; Cappato, Riccardo; Di Leo, Giovanni; Secchi, Francesco; Papini, Giacomo D E; Foresti, Sara; Ali, Hussam; De Ambroggi, Guido M G; Sorgente, Antonio; Epicoco, Gianluca; Cannaò, Paola M; Sardanelli, Francesco

    2018-06-01

    To investigate safety and diagnostic value of 1.5-T MRI in carriers of conventional pacemaker (cPM) or conventional implantable defibrillator (cICD). We prospectively compared cPM/cICD-carriers undergoing MRI (study group, SG), excluding those device-dependent or implanted cPM/cICD-carriers undergoing chest x-ray, CT or follow-up (reference group, RG). 142 MRI (55 cardiac) were performed in 120 patients with cPM (n=71) or cICD (n=71). In the RG 98 measurements were performed in 95 patients with cPM (n=40) or cICD (n=58). No adverse events were observed. No MRI prolonged/interrupted. All cPM/cICD were correctly reprogrammed after MRI without malfunctions. One temporary communication failure was observed in one cPM-carrier. Immediately after MRI, 12/14 device interrogation parameters did not change significantly (clinically negligible changes of battery voltage and cICD charging time), without significant variations for SG versus RG. Three-12 months after MRI, 9/11 device interrogation parameters did not change significantly (clinically negligible changes of battery impedance/voltage). Non-significant changes of three markers of myocardial necrosis. Non-cardiac MRI: 82/87 diagnostic without artefacts; 4/87 diagnostic with artefacts; 1/87 partially diagnostic. Cardiac MRI: in cPM-carriers, 14/15 diagnostic with artefacts, 1/15 partially diagnostic; in cICD-carriers, 9/40 diagnostic with artefacts, 22 partially diagnostic, nine non-diagnostic. A favourable risk-benefit ratio of 1.5-T MRI in cPM/cICD carriers was reported. • Cooperation between radiologists and cardiac electrophysiologists allowed safe 1.5-T MRI in cPM/cICD-carriers. • No adverse events for 142 MRI in 71 cPM-carriers and 71 cICD-carriers. • Ninety-nine per cent (86/87) of non-cardiac MRI in cPM/cICD-carriers were diagnostic. • All cPM-carrier cardiac MRIs had artefacts, 14 examinations diagnostic, 1 partially diagnostic. • Twenty-three per cent (9/40) of cardiac MRI in cICD-carriers were non-diagnostic.

  1. Psychological intervention following implantation of an implantable defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F

    2007-01-01

    The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current ...

  2. Sexual Health for Patients with an Implantable Cardioverter Defibrillator

    Science.gov (United States)

    ... sex for most patients represents only a moderate stress on the heart. Proposed Strategy Sex is a common concern, but most sexual activity ... all of your efforts, there are times when stress like this cannot be handled by ... patients should not engage in sex. Even if you feel you are not physically ...

  3. Questions to Ask Your Doctor--Implantable Cardioverter Defibrillator (ICD)

    Science.gov (United States)

    ... family member or I still drive, travel, have sex, work out or continue other activities we enjoy? How ... in Children • Arrhythmia Tools & Resources Answers by Heart Fact Sheets Learn and live with our downloadable patient ...

  4. How to Respond to an Implantable Cardioverter-Defibrillator Recall

    Science.gov (United States)

    ... managing your emotions appropriately and being proactive. Behavioral Management Plan Your best plan of action is to ... recall for all patients. The recall of 1 brand of ICD does not mean that there is ...

  5. Implantable cardioverter defibrillator does not cure the heart.

    Science.gov (United States)

    Sławuta, Agnieszka; Boczar, Krzysztof; Ząbek, Andrzej; Gajek, Jacek; Lelakowski, Jacek; Vijayaraman, Pugazhendhi; Małecka, Barbara

    2018-01-23

    A man with non-ischemic cardiomyopathy, EF 22%, permanent AF and ICD was admitted for elective device replacement. The need for the optimization of the ventricular rate and avoidance of right ventricular pacing made it necessary to up-grade the existing pacing system using direct His bundle pacing and dual chamber ICD. This enabled the regularization of ventricular rate, avoiding the RV pacing and optimize the beta-blocker dose. The one month follow-up already showed reduction in left ventricle diameter, improvement in ejection fraction, NYHA class decrease to II. The His bundle pacing enabled the optimal treatment of the patient resulting in excellent clinical improvement.

  6. Depression, psychological distress, and quality of life in patients with cardioverter defibrillator with or without cardiac resynchronization therapy.

    Science.gov (United States)

    Knackstedt, Christian; Arndt, Marlies; Mischke, Karl; Marx, Nikolaus; Nieman, Fred; Kunert, Hanns Jürgen; Schauerte, Patrick; Norra, Christine

    2014-05-01

    Congestive heart failure is frequent and leads to reduced exercise capacity, reduced quality of life (QoL), and depression in many patients. Cardiac resynchronization therapy (CRT) and implantable cardioverter defibrillators (ICD) offer therapeutic options and may have an impact on QoL and depression. This study was performed to evaluate physical and mental health in patients undergoing ICD or combined CRT/ICD-implantation (CRT-D). Echocardiography, spiroergometry, and psychometric questionnaires [Beck Depression Inventory, General World Health Organization Five Well-being Index (WHO-5), Brief Symptom Inventory and 36-item Short Form (SF-36)] were obtained in 39 patients (ICD: 17, CRT-D: 22) at baseline and 6-month follow-up (FU) after device implantation. CRT-D patients had a higher NYHA class and broader left bundle branch block than ICD patients at baseline. At FU, ejection fraction (EF), peak oxygen uptake, and NYHA class improved significantly in CRT-D patients but remained unchanged in ICD patients. Patients with CRT-D implantation showed higher levels of depressive symptoms, psychological distress, and impairment in QoL at baseline and FU compared to ICD patients. These impairments remained mostly unchanged in all patients after 6 months. Overall, these findings imply that there is a need for careful assessment and treatment of psychological distress and depression in ICD and CRT-D patients in the course of device implantation as psychological burden seems to persist irrespective of physical improvement.

  7. Prophylactic implantable defibrillator in patients with arrhythmogenic right ventricular cardiomyopathy/dysplasia and no prior ventricular fibrillation or sustained ventricular tachycardia.

    LENUS (Irish Health Repository)

    Corrado, Domenico

    2010-09-21

    The role of implantable cardioverter-defibrillator (ICD) in patients with arrhythmogenic right ventricular cardiomyopathy\\/dysplasia and no prior ventricular fibrillation (VF) or sustained ventricular tachycardia is an unsolved issue.

  8. Minimal invasive epicardial lead implantation: optimizing cardiac resynchronization with a new mapping device for epicardial lead placement.

    Science.gov (United States)

    Maessen, J G; Phelps, B; Dekker, A L A J; Dijkman, B

    2004-05-01

    To optimize resynchronization in biventricular pacing with epicardial leads, mapping to determine the best pacing site, is a prerequisite. A port access surgical mapping technique was developed that allowed multiple pace site selection and reproducible lead evaluation and implantation. Pressure-volume loops analysis was used for real time guidance in targeting epicardial lead placement. Even the smallest changes in lead position revealed significantly different functional results. Optimizing the pacing site with this technique allowed functional improvement up to 40% versus random pace site selection.

  9. Immediate electrical storm of Torsades de Pointes after CRT-D implantation in an ischemic cardiomyopathy patient

    Directory of Open Access Journals (Sweden)

    Adnan Kaya, MD

    2015-06-01

    Full Text Available Cardiac resynchronization therapy with an implantable cardioverter-defibrillator (CRT-D is the preferred treatment for patients with severe heart failure, dyssynchrony, and an increased risk of sudden cardiac death or for primary ventricular arrhythmia survivors. Rarely, left ventricular epicardial pacing can induce ventricular tachyarrhythmia rather than a beneficial effect. We describe an ischemic cardiomyopathy patient who underwent CRT-D therapy and developed sustained torsades de pointes (TdP immediately after switching to biventricular pacing (BVP mode. Here, TdP possibly developed owing to the change in the dispersion of repolarization of the left ventricle myocardium. The diagnosis and management of BVP-induced ventricular arrhythmia is discussed.

  10. Intensity of primary emotions in patients after implantation of an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Stoier, Louise; Pedersen, Preben Ulrich; Berg, Selina Kikkenborg

    2013-01-01

    -November 2009. A total number of 154 patients were needed in the trial. The data collected were compared with secondary data from patients who had recently suffered a Myocardial Infarction and from a healthy population. SPSS version 18.0 was used to analyze the data using t-test, chisquare and F...

  11. Association between socioeconomic factors and ICD implantation in a publicly financed health care system

    DEFF Research Database (Denmark)

    Winther-Jensen, Matilde; Hassager, Christian; Lassen, Jens Flensted

    2017-01-01

    Aims: For patients surviving out-of-hospital cardiac arrest (OHCA) with a shockable rhythm, implantable cardioverter defibrillator (ICD) is recommended for non-reversible causes of arrest. We aimed to determine factors associated with implantation of ICD and survival in patients surviving non...... admission. Association to ICD implantation during index admission was analysed in logistic regression, survival was assessed using Cox regression. Implantable cardioverter defibrillator implantation increased during the study period [odds ratio (OR) 1-year increase: 1.04, 95% confidence intervals (95% CI...

  12. Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block.

    Science.gov (United States)

    Costa, Roberto; Silva, Katia Regina da; Martinelli Filho, Martino; Carrillo, Roger

    2017-10-01

    Few studies have characterized the surgical outcomes following epicardial pacemaker implantation in neonates with congenital complete atrioventricular block (CCAVB). This study sought to assess the long-term outcomes of a minimally invasive epicardial approach using a subxiphoid access for pacemaker implantation in neonates. Between July 2002 and February 2015, 16 consecutive neonates underwent epicardial pacemaker implantation due to CCAVB. Among these, 12 (75.0%) had congenital heart defects associated with CCAVB. The patients had a mean age of 4.7 ± 5.3 days and nine (56.3%) were female. Bipolar steroid-eluting epicardial leads were implanted in all patients through a minimally invasive subxiphoid approach and fixed on the diaphragmatic ventricular surface. The pulse generator was placed in an epigastric submuscular position. All procedures were successful, with no perioperative complications or early deaths. Mean operating time was 90.2 ± 16.8 minutes. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 4.1 ± 3.9 years. Three children underwent pulse generator replacement due to normal battery depletion at 4.0, 7.2, and 9.0 years of age without the need of ventricular lead replacement. There were two deaths at 12 and 325 days after pacemaker implantation due to bleeding from thrombolytic use and progressive refractory heart failure, respectively. Epicardial pacemaker implantation through a subxiphoid approach in neonates with CCAVB is technically feasible and associated with excellent surgical outcomes and pacing lead longevity.

  13. The learning curve associated with the introduction of the subcutaneous implantable defibrillator

    NARCIS (Netherlands)

    Knops, Reinoud E.; Brouwer, Tom F.; Barr, Craig S.; Theuns, Dominic A.; Boersma, Lucas; Weiss, Raul; Neuzil, Petr; Scholten, Marcoen; Lambiase, Pier D.; Leon, Angel R.; Hood, Margaret; Jones, Paul W.; Wold, Nicholas; Grace, Andrew A.; Olde Nordkamp, Louise R. A.; Burke, Martin C.

    2016-01-01

    Aims The subcutaneous implantable cardioverter defibrillator (S-ICD) was introduced to overcome complications related to transvenous leads. Adoption of the S-ICD requires implanters to learn a new implantation technique. The aim of this study was to assess the learning curve for S-ICD implanters

  14. [Septic shock due to infective endocarditis of stimulation system of implantable cardioverter-defibrillator].

    Science.gov (United States)

    Porubčinová, I; Porubčin, S; Stančák, B; Beňa, M; Sabol, F

    2012-01-01

    We present a case of a 60-year old patient hospitalized at the Department of Infectious Diseases and Travel Medicine, Medical faculty of UPJS and L. Pasteurs University Hospital in Kosice with suspected gastroenteritis. The patient was admitted to an intensive care unit because of the signs of septic shock. Within one hour from admission, the patient was administered early goal directed therapy for septic shock. Subsequently, infectious endocarditis of stimulation electrodes and tricuspid valve was identified as the origin of the infection. The stimulation system was then explanted from a stabilized and afebrile patient at the Department of cardiac Surgery of Eastern Slovak Institute of Cardiac and Vascular Diseases in Kosice. This case should emphasise frequently atypical course of this serious disease and the need for early identification of severe sepsis to enable timely management to affect mortality.

  15. Emotional distress in partners of patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Van Den Broek, Krista C; Habibović, Mirela; Pedersen, Susanne S.

    2010-01-01

    on psychological distress in partners of ICD patients and recommendations for future research. PubMed and PsycInfo were searched in March 2010 using a priori defined search terms. This search and the additional hand search resulted in 22 studies, of which 13 were quantitative and eight qualitative. Sample sizes...... studies reported no impact of ICD shocks on distress levels or quality of life in partners. ICD indication as well as comorbid conditions, age, and the psychological profile of the partner were related to distress and quality of life. Domains of concern emerging from qualitative studies were related...... to care of the ICD patient, helplessness and uncertainties related to shocks, role changes, sexual activities, overprotectiveness, and driving. Partner levels of distress may be as high as that of ICD patients. Research with large samples is needed to further investigate the course and determinants...

  16. Low disease prevalence and inappropriate implantable cardioverter defibrillator shock rate in Brugada syndrome

    DEFF Research Database (Denmark)

    Holst, Anders Gaarsdal; Jensen, Henrik Kjærulf; Eschen, Ole

    2012-01-01

    AimsBrugada syndrome (BrS) is an inherited channelopathy that predisposes to malignant ventricular arrhythmias and thereby syncope and sudden cardiac death. Prior studies characterizing BrS patients have used highly selected referral populations from tertiary centres and prevalence estimates have...... been carried out using electrocardiogram (ECG) surveys only. We aimed to identify and characterize all diagnosed BrS patients in Denmark (population 5.4 million).Methods and resultsBrugada syndrome patients were identified using several modalities including identification in all Danish tertiary......%) experienced inappropriate shocks during a median follow-up of 47 months. No patient died or experienced aborted sudden cardiac death during follow-up.ConclusionsWe report the first nationwide study of BrS patients. We found a low incidence of diagnosed definite BrS compared with estimates from ECG surveys...

  17. Poor perceived social support in implantable cardioverter defibrillator (ICD) patients and their partners

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Spinder, Helle; Erdman, Ruud A M

    2009-01-01

    Social support is a known buffer of psychological distress and has also been shown to influence adverse medical outcomes.......Social support is a known buffer of psychological distress and has also been shown to influence adverse medical outcomes....

  18. Extended charge banking model of dual path shocks for implantable cardioverter defibrillators.

    Science.gov (United States)

    Dosdall, Derek J; Sweeney, James D

    2008-08-01

    Single path defibrillation shock methods have been improved through the use of the Charge Banking Model of defibrillation, which predicts the response of the heart to shocks as a simple resistor-capacitor (RC) circuit. While dual path defibrillation configurations have significantly reduced defibrillation thresholds, improvements to dual path defibrillation techniques have been limited to experimental observations without a practical model to aid in improving dual path defibrillation techniques. The Charge Banking Model has been extended into a new Extended Charge Banking Model of defibrillation that represents small sections of the heart as separate RC circuits, uses a weighting factor based on published defibrillation shock field gradient measures, and implements a critical mass criteria to predict the relative efficacy of single and dual path defibrillation shocks. The new model reproduced the results from several published experimental protocols that demonstrated the relative efficacy of dual path defibrillation shocks. The model predicts that time between phases or pulses of dual path defibrillation shock configurations should be minimized to maximize shock efficacy. Through this approach the Extended Charge Banking Model predictions may be used to improve dual path and multi-pulse defibrillation techniques, which have been shown experimentally to lower defibrillation thresholds substantially. The new model may be a useful tool to help in further improving dual path and multiple pulse defibrillation techniques by predicting optimal pulse durations and shock timing parameters.

  19. Clinical effects and implications of cardiac rehabilitation for implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Moons, Philip; Christensen, Anne Vingaard

    2015-01-01

    rehabilitation and usual care was found in physical capacity and general and mental health. However, the clinical effect sizes of these findings were not investigated, and the findings from the quantitative and qualitative analyses were not triangulated to address the issue of whether the qualitative results...... could help explain the quantitative results and bring forward additional information. OBJECTIVES:: The objectives are to (a) determine the clinical effect sizes of the primary outcomes and (b) triangulate the quantitative and qualitative findings. METHODS:: A total of 196 patients with first...... d was calculated. Qualitative interviews were conducted with 10 patients representing the rehabilitation group. Triangulation was carried out by integrating the findings from the quantitative and qualitative results in light of each other. RESULTS:: Clinically meaningful effects were found between...

  20. Effects of an alert system on implantable cardioverter defibrillator-related anxiety

    DEFF Research Database (Denmark)

    Duru, Firat; Dorian, Paul; Favale, Stefano

    2010-01-01

    failing to receive needed therapy for the same reason. New devices include programmable vibrating patient notifiers (PN), which, by warning patients of a possible device dysfunction, might lower device-related anxiety. PAtient NOtifier feature for Reduction of Anxiety: a Multicentre ICD study (PANORAMIC......) is a multicentre, randomized, clinical trial designed to examine the effects of the awareness of an active vibrating alert system on device-related anxiety....

  1. The NO Regular Defibrillation testing In Cardioverter Defibrillator Implantation (NORDIC ICD) trial

    DEFF Research Database (Denmark)

    Bänsch, Dietmar; Bonnemeier, Hendrik; Brandt, Johan

    2015-01-01

    was standardized across all participating centres. After inducing a fast ventricular tachycardia (VT) with a heart rate ≥240 b.p.m. or ventricular fibrillation (VF) with a low-energy T-wave shock, DF was attempted with an initial 15 J shock. If the shock reversed the VT or VF, DF testing was considered successful...... and terminated. If unsuccessful, two effective 24 J shocks were administered. If DF was unsuccessful, the system was reconfigured and another DF testing was performed. An ICD shock energy of 40 J had to be programmed in all patients for treatment of spontaneous VT/VF episodes. The primary endpoint...

  2. Shock as a determinant of poor patient-centered outcomes in implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Van Den Broek, Krista C; Van Den Berg, Martha

    2010-01-01

    as an outcome, and compare the influence of ICD shock with other factors (e.g., heart failure and psychological factors) as determinants of outcomes, with a view to providing recommendations for clinical practice and future research. Based on the large-scale primary and secondary prevention trials (i.e., CABG......-PATCH, CIDS, AVID, AMIOVIRT, SCD-HeFT, MADIT-II, and DEFINITE), evidence for an association between ICD shocks and quality of life is mixed, with some indication that the influence of shocks may depend largely on the interval between shocks and assessment of quality of life. In order to improve the clinical...... management of ICD patients, we need to adopt a more rigorous and standardized methodology in future studies in order to be able to draw firm conclusions about the impact of ICD shocks on individual patients. We also need to acknowledge that the impact of shocks on psychological functioning and quality...

  3. Long-term mortality risk in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Theuns, Dominic A M J; Pedersen, Susanne S.

    2014-01-01

    .9)). The impact of heart rate and QRS duration on time to all-cause mortality was separately assessed with Cox proportional hazard regression analysis, adjusting for clinical factors and symptoms of depression and anxiety. RESULTS: Mean (SD) heart rate was 68.0 ± 13.3 bpm and mean QRS duration was 130.9 ± 36.9 ms....... Heart rate of ≥80 bpm was associated with increased risk of mortality (HR=1.86; 95% CI=1.15-3.00; p=.011) in unadjusted analysis. In adjusted analyses, this relationship remained significant both with depression (HR=1.86, 95% CI=1.12-3.09; p=.017) and anxiety (HR=1.82, 95% CI=1.10-3.03; p=.021...

  4. Long-term survival of implantable cardioverter defibrillator recipients with end-stage renal disease

    Directory of Open Access Journals (Sweden)

    Mikhael F. El-Chami, MD, FACC, FHRS

    2017-10-01

    Conclusion: ESRD patients are at significantly increased risk of mortality as compared with a non-dialysis cohort. While the majority of these patients survive more than one year post-diagnosis, the three-year mortality is high (43%. Randomized studies addressing the benefits of ICDs in ESRD patients are needed to better define their value for primary prevention of SCD.

  5. Failure to Treat Life-Threatening Ventricular Tachyarrhythmias in Contemporary Implantable Cardioverter-Defibrillators

    DEFF Research Database (Denmark)

    Thøgersen, Anna Margrethe; Larsen, Jacob Moesgaard; Johansen, Jens Brock

    2017-01-01

    . CONCLUSIONS: Complex and unanticipated interactions between manufacturer-specific features and generic programming can prevent therapy for VF. More data are needed to assess the risks and benefits of translating evidence-based detection parameters from one manufacturer to another....

  6. Coping with Trauma and Stressful Events As a Patient with an Implantable Cardioverter-Defibrillator

    Science.gov (United States)

    ... Circulation My alerts Sign In Join Sign out Facebook Twitter Home About this Journal Editorial Board General Statistics Circulation Doodle Information for Advertisers Author Reprints Commercial Reprints Customer Service and Ordering ...

  7. Relation of statin therapy to psychological functioning in patients with an implantable cardioverter defibrillator

    NARCIS (Netherlands)

    Hoogwegt, M.T.; Theuns, D.A.M.J.; Kupper, N.; Jordaens, L.; Pedersen, S.S.

    2013-01-01

    Statin therapy is an important secondary prevention measure in cardiovascular disease. However, the side effects associated with statin use could potentially affect patients' quality of life. Little is known about the influence of statin therapy on the well-being and health status of cardiac

  8. My Child Needs or Has an Implantable Cardioverter-Defibrillator: What Should I Do?

    Science.gov (United States)

    ... al. 7 How Can We Boost My Child's Self-Esteem? No matter what the age, a fun way ... to treatment among children with cardiac disease . Cardiol Young . 2009 ; 19 : 545 – 551 . OpenUrl CrossRef PubMed 3. ↵ ...

  9. 77 FR 20873 - Qualification of Drivers; Application for Exemptions; Implantable Cardioverter Defibrillators

    Science.gov (United States)

    2012-04-06

    ..., please include a self-addressed, stamped envelope or postcard or print the acknowledgement page that... variety known to be accompanied by syncope, dyspnea, collapse, or congestive cardiac failure. FMCSA..., collapse or congestive cardiac failure; and/or (2) which is likely to cause syncope, dyspnea, collapse, or...

  10. Sex differences in outcomes of primary prevention implantable cardioverter defibrillator therapy

    DEFF Research Database (Denmark)

    Sticherling, Christian; Arendacka, Barbora; Svendsen, Jesper Hastrup

    2018-01-01

    measures were overall mortality and first appropriate and first inappropriate shocks. A multivariable model enforcing a common hazard ratio for sex category across the centres, but allowing for centre-specific baseline hazards and centre specific effects of other covariates, was adjusted for age...

  11. Comprehensive cardiac rehabilitation improves outcome for patients with implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Pedersen, Preben Ulrich; Zwisler, Ann-Dorthe

    2015-01-01

    year of psycho-educational follow-up focusing on modifiable factors associated with poor outcomes. Two primary outcomes, general health score (Short Form-36 (SF-36)) and peak oxygen uptake (VO2), were used. Post-hoc analyses included SF-36 and ICD therapy history.Results:Comprehensive cardiac...

  12. Risk of chronic anxiety in implantable defibrillator patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; den Broek, Krista C van; Theuns, Dominic A M J

    2011-01-01

    Little is known about the prevalence of chronic anxiety in patients with an implantable cardioverter defibrillator (ICD). In a multi-center, prospective study, we examined 1) the prevalence of chronic anxiety (i.e., patients anxious at implantation and 12 months), and 2) predictors of chronic...... anxiety....

  13. The learning curve associated with the introduction of the subcutaneous implantable defibrillator

    NARCIS (Netherlands)

    R.E. Knops (Reinoud); T.F. Brouwer (Tom F.); C.S. Barr (Craig); D.A.M.J. Theuns (Dominic); L. Boersma (Lucas); R. Weiss (Ram); P. Neuzil (Petr); M.F. Scholten (Marcoen); P.D. Lambiase (Pier); A. Leon (Angel); A.M. Hood (Margaret); P. Jones; Wold, N. (Nicholas); Grace, A.A. (Andrew A.); L.R.A. Olde Nordkamp (Louise R.A.); M.C. Burke (Martin)

    2016-01-01

    textabstractAims: The subcutaneous implantable cardioverter defibrillator (S-ICD) was introduced to overcome complications related to transvenous leads. Adoption of the S-ICD requires implanters to learn a new implantation technique. The aim of this study was to assess the learning curve for S-ICD

  14. Implantable defibrillator therapy: more than defibrillation...

    NARCIS (Netherlands)

    D.A.M.J. Theuns (Dominic)

    2005-01-01

    textabstractDuring the past 25 years, the implantable cardioverter-defibrillator (ICD) has evolved from the treatment of last resort to the gold standard for patients at high risk for life­threatening ventricular tachyarrhythmias. Patients at high risk include those who survived life-threatening

  15. Wearable cardioverter defibrillators for the prevention of sudden cardiac arrest: a health technology assessment and patient focus group study

    Directory of Open Access Journals (Sweden)

    Ettinger S

    2017-11-01

    Full Text Available Sabine Ettinger,1 Michal Stanak,1 Piotr Szymański,2 Claudia Wild,1 Romana Tandara Haček,3 Darija Erčević,3 Renata Grenković,3 Mirjana Huić3 1Ludwig Boltzmann Institute for Health Technology Assessment, Vienna, Austria; 2Institute of Cardiology, Warsaw, Poland; 3Department for Development, Research and Health Technology Assessment, Agency for Quality and Accreditation in Health Care and Social Welfare, Zagreb, Croatia Aim: To summarize the evidence on clinical effectiveness and safety of wearable cardioverter defibrillator (WCD therapy for primary and secondary prevention of sudden cardiac arrest in patients at risk. Methods: We performed a systematic literature search in databases including MEDLINE via OVID, Embase, the Cochrane Library, and CRD (DARE, NHS-EED, HTA. The evidence obtained was summarized according to GRADE methodology. A health technology assessment (HTA was conducted using the HTA Core Model® for rapid relative effectiveness assessment. Primary outcomes for the clinical effectiveness domain were all-cause and disease-specific mortality. Outcomes for the safety domain were adverse events (AEs and serious adverse events (SAEs. A focus group with cardiac disease patients was conducted to evaluate ethical, organizational, patient, social, and legal aspects of the WCD use. Results: No randomized- or non-randomized controlled trials were identified. Non-comparative studies (n=5 reported AEs including skin rash/itching (6%, false alarms (14%, and palpitations/light-headedness/fainting (9% and discontinuation due to comfort/lifestyle issues (16–22%, and SAEs including inappropriate shocks (0–2%, unsuccessful shocks (0–0.7%, and death (0–0.3%. The focus group results reported that experiencing a sense of security is crucial to patients and that the WCD is not considered an option for weeks or even months due to expected restrictions in living a “normal” life. Conclusion: The WCD appears to be relatively safe for short

  16. Novel approach to epicardial pacemaker implantation in patients with limited venous access.

    Science.gov (United States)

    Costa, Roberto; Scanavacca, Mauricio; da Silva, Kátia Regina; Martinelli Filho, Martino; Carrillo, Roger

    2013-11-01

    Limited venous access in certain patients increases the procedural risk and complexity of conventional transvenous pacemaker implantation. The purpose of this study was to determine a minimally invasive epicardial approach using pericardial reflections for dual-chamber pacemaker implantation in patients with limited venous access. Between June 2006 and November 2011, 15 patients underwent epicardial pacemaker implantation. Procedures were performed through a minimally invasive subxiphoid approach and pericardial window with subsequent fluoroscopy-assisted lead placement. Mean patient age was 46.4 ± 15.3 years (9 male [(60.0%], 6 female [40.0%]). The new surgical approach was used in patients determined to have limited venous access due to multiple abandoned leads in 5 (33.3%), venous occlusion in 3 (20.0%), intravascular retention of lead fragments from prior extraction in 3 (20.0%), tricuspid valve vegetation currently under treatment in 2 (13.3%), and unrepaired intracardiac defects in 2 (13.3%). All procedures were successful with no perioperative complications or early deaths. Mean operating time for isolated pacemaker implantation was 231.7 ± 33.5 minutes. Lead placement on the superior aspect of right atrium, through the transverse sinus, was possible in 12 patients. In the remaining 3 patients, the atrial lead was implanted on the left atrium through the oblique sinus, the postcaval recess, or the left pulmonary vein recess. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 36.8 ± 25.1 months. Epicardial pacemaker implantation through pericardial reflections is an effective alternative therapy for those patients requiring physiologic pacing in whom venous access is limited. © 2013 Heart Rhythm Society. All rights reserved.

  17. Shock whilst gardening--implantable defibrillators & lawn mowers.

    Science.gov (United States)

    Von Olshausen, G; Lennerz, C; Grebmer, C; Pavaci, H; Kolb, C

    2014-02-01

    Electromagnetic interference with implantable cardioverter defibrillators (ICDs) can cause inappropriate shock delivery or temporary inhibition of ICD functions. We present a case of electromagnetic interference between a lawn mower and an ICD resulting in an inappropriate discharge of the device due to erroneous detection of ventricular fibrillation.

  18. Long-Term Clinical Outcomes of Subcutaneous Versus Transvenous Implantable Defibrillator Therapy

    NARCIS (Netherlands)

    Brouwer, Tom F.; Yilmaz, Dilek; Lindeboom, Robert; Buiten, Maurits S.; Olde Nordkamp, Louise R. A.; Schalij, Martin J.; Wilde, Arthur A.; van Erven, Lieselot; Knops, Reinoud E.

    2016-01-01

    Transvenous implantable cardioverter-defibrillators (TV-ICDs) improve survival in patients at risk for sudden cardiac death, but complications remain an important drawback. The subcutaneous ICD (S-ICD) was developed to overcome lead-related complications. Comparison of clinical outcomes of both

  19. An unusual etiological agent of implantable cardioverter device endocarditis: Corynebacterium mucifaciens

    Directory of Open Access Journals (Sweden)

    Adnan Kaya

    2016-03-01

    Full Text Available Cardiac pacing devices and implantable cardioverter defibrillator (ICD are becoming the mainstay of therapy in cardiology and infective endocarditis (IE and pocket infection; however, these devices require careful monitoring. Here, we describe a case of a 68-year-old female with an ICD presenting with a previously unknown etiological agent of IE, Corynebacterium mucifaciens.

  20. Combined leadless pacemaker and subcutaneous implantable defibrillator therapy: feasibility, safety, and performance

    NARCIS (Netherlands)

    Tjong, F. V. Y.; Brouwer, T. F.; Smeding, L.; Kooiman, K. M.; de Groot, J. R.; Ligon, D.; Sanghera, R.; Schalij, M. J.; Wilde, A. A. M.; Knops, R. E.

    2016-01-01

    The subcutaneous implantable cardioverter-defibrillator (S-ICD) and leadless pacemaker (LP) are evolving technologies that do not require intracardiac leads. However, interactions between these two devices are unexplored. We investigated the feasibility, safety, and performance of combined LP and

  1. Pacemaker, implanted cardiac defibrillator and irradiation: Management proposal in 2010 depending on the type of cardiac stimulator and prognosis and location of cancer

    International Nuclear Information System (INIS)

    Lambert, P.; Da Costa, A.; Marcy, P.Y.; Kreps, S.; Angellier, G.; Marcie, S.; Bondiau, P.Y.; Briand-Amoros, C.; Thariat, J.

    2011-01-01

    Ionizing radiation may interfere with electric components of pacemakers or implantable cardioverter defibrillators. The type, severity and extent of radiation damage to pacemakers, have previously been shown to depend on the total dose and dose rate. Over 300,000 new cancer cases are treated yearly in France, among which 60% are irradiated in the course of their disease. One among 400 of these patients has an implanted pacemaker or defibrillator. The incidence of pacemaker and implanted cardioverter defibrillator increases in an ageing population. The oncologic prognosis must be weighted against the cardiologic prognosis in a multidisciplinary and transversal setting. Innovative irradiation techniques and technological sophistications of pacemakers and implantable cardioverter-defibrillators (with the introduction of more radiosensitive complementary metal-oxide-semiconductors since 1970) have potentially changed the tolerance profiles. This review of the literature studied the geometric, dosimetric and radiobiological characteristics of the radiation beams for high energy photons, stereotactic irradiation, proton-therapy. Standardized protocols and radiotherapy optimization (particle, treatment fields, energy) are advisable in order to improve patient management during radiotherapy and prolonged monitoring is necessary following radiation therapy. The dose received at the pacemaker/heart should be calculated. The threshold for the cumulated dose to the pacemaker/implantable cardioverter-defibrillator (2 to 5 Gy depending on the brand), the necessity to remove/displace the device based on the dose-volume histogram on dosimetry, as well as the use of lead shielding and magnet are discussed. (authors)

  2. Pacemaker, implanted cardiac defibrillator and irradiation: Management proposal in 2010 depending on the type of cardiac stimulator and prognosis and location of cancer; Pacemaker, defibrillateur et radiotherapie: propositions de conduite a tenir en 2010 en fonction du type de stimulateur cardiaque, du pronostic et du site du cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, P. [Service d' anesthesie reanimation, hopital Nord, centre hospitalier universitaire de Saint-etienne, 42055 Saint-etienne cedex 2 (France); Da Costa, A. [Service de cardiologie, hopital Nord, centre hospitalier universitaire de Saint-etienne, 42055 Saint-etienne cedex 2 (France); Marcy, P.Y. [Departement de radiologie, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Kreps, S. [Service de radiotherapie Corad, centre regional universitaire de cancerologie Henry-S.-Kaplan, hopital Bretonneau-2, CHU de Tours, boulevard Tonnelle, 37000 Tours (France); Angellier, G.; Marcie, S.; Bondiau, P.Y. [Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Departement de radiotherapie oncologie, centre CyberKnife, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Briand-Amoros, C. [Service de radiotherapie, hopital europeen Georges-Pompidou, 20, rue Leblanc, 75015 Paris (France); Thariat, J. [Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Departement de radiotherapie oncologie, centre CyberKnife, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); IBDC CNRS UMR 6543, centre Antoine-Lacassagne, universite Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France)

    2011-06-15

    Ionizing radiation may interfere with electric components of pacemakers or implantable cardioverter defibrillators. The type, severity and extent of radiation damage to pacemakers, have previously been shown to depend on the total dose and dose rate. Over 300,000 new cancer cases are treated yearly in France, among which 60% are irradiated in the course of their disease. One among 400 of these patients has an implanted pacemaker or defibrillator. The incidence of pacemaker and implanted cardioverter defibrillator increases in an ageing population. The oncologic prognosis must be weighted against the cardiologic prognosis in a multidisciplinary and transversal setting. Innovative irradiation techniques and technological sophistications of pacemakers and implantable cardioverter-defibrillators (with the introduction of more radiosensitive complementary metal-oxide-semiconductors since 1970) have potentially changed the tolerance profiles. This review of the literature studied the geometric, dosimetric and radiobiological characteristics of the radiation beams for high energy photons, stereotactic irradiation, proton-therapy. Standardized protocols and radiotherapy optimization (particle, treatment fields, energy) are advisable in order to improve patient management during radiotherapy and prolonged monitoring is necessary following radiation therapy. The dose received at the pacemaker/heart should be calculated. The threshold for the cumulated dose to the pacemaker/implantable cardioverter-defibrillator (2 to 5 Gy depending on the brand), the necessity to remove/displace the device based on the dose-volume histogram on dosimetry, as well as the use of lead shielding and magnet are discussed. (authors)

  3. Association between implantable cardioverter-defibrillator therapy and different lead positions in patients with cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Kronborg, Mads Brix; Johansen, Jens Brock; Haarbo, Jens

    2017-01-01

    /mid-ventricular/apical for the LV-LP, and as apical/non-apical for the RV-LP. Appropriate and inappropriate therapies were registered during follow-up via remote monitoring or at device interrogations. Time to event was summarized with Kaplan-Meier plots, and competed risk regression analysis was used to calculate adjusted hazard...... with an apical. We observed no significant association between appropriate therapy and LV-LP in left anterior oblique or right anterior oblique views or inappropriate therapy between any lead positions. Conclusion: An apical RV-LP is associated with an increased risk of appropriate therapy for ventricular...

  4. Cost-Effectiveness of Adding Cardiac Resynchronization Therapy to an Implantable Cardioverter-Defibrillator Among Patients With Mild Heart Failure

    DEFF Research Database (Denmark)

    Woo, Christopher Y; Strandberg, Erika J; Schmiegelow, Michelle D

    2015-01-01

    -defibrillator (ICD) alone among patients with left ventricular systolic dysfunction, prolonged intraventricular conduction, and mild heart failure. DESIGN: Markov decision model. DATA SOURCES: Clinical trials, clinical registries, claims data from Centers for Medicare & Medicaid Services, and Centers for Disease...

  5. The Screen-ICD trial. Screening for anxiety and cognitive therapy intervention for patients with implanted cardioverter defibrillator (ICD)

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Herning, Margrethe; Svendsen, Jesper Hastrup

    2016-01-01

    by Structured Clinical Interview for DSM Disorders (SCID). (3) Investigator-initiated randomised clinical superiority trial with blinded outcome assessment, with 1:1 randomisation to cognitive–behavioural therapy (CBT) performed by a cardiac nurse with CBT training, plus usual care or usual care alone...... of starting relevant intervention. Methods and analysis: Screen-ICD consists of 3 parts: (1) screening of all hospitalised and outpatient patients at two university hospitals using the Hospital Anxiety and Depression Scale (HADS), scores ≥8 are invited to participate. (2) Assessment of type of anxiety...

  6. Where Does It Lead? Imaging Features of Cardiovascular Implantable Electronic Devices on Chest Radiograph and CT

    Energy Technology Data Exchange (ETDEWEB)

    Lanzman, Rotem S.; Blondin, Dirk; Furst, Gunter; Scherer, Axel; R Miese, Falk; Kroepil, Patric [University of Duesseldorf, Medical Faculty, 40225 Duesseldorf (Germany); Winter, Joachim [University Hospital Duesseldorf, 40225 Duesseldorf (Germany); Abbara, Suhny [Massachusetts General Hospital, Boston, MA (US)

    2011-10-15

    Pacemakers and implantable cardioverter defibrillators (ICDs) are being increasingly employed in patients suffering from cardiac rhythm disturbances. The principal objective of this article is to familiarize radiologists with pacemakers and ICDs on chest radiographs and CT scans. Therefore, the preferred lead positions according to pacemaker types and anatomic variants are introduced in this study. Additionally, the imaging features of incorrect lead positions and defects, as well as complications subsequent to pacemaker implantation are demonstrated herein.

  7. Where Does It Lead? Imaging Features of Cardiovascular Implantable Electronic Devices on Chest Radiograph and CT

    International Nuclear Information System (INIS)

    Lanzman, Rotem S.; Blondin, Dirk; Furst, Gunter; Scherer, Axel; R Miese, Falk; Kroepil, Patric; Winter, Joachim; Abbara, Suhny

    2011-01-01

    Pacemakers and implantable cardioverter defibrillators (ICDs) are being increasingly employed in patients suffering from cardiac rhythm disturbances. The principal objective of this article is to familiarize radiologists with pacemakers and ICDs on chest radiographs and CT scans. Therefore, the preferred lead positions according to pacemaker types and anatomic variants are introduced in this study. Additionally, the imaging features of incorrect lead positions and defects, as well as complications subsequent to pacemaker implantation are demonstrated herein.

  8. Twenty-Seven Years Experience With Transvenous Pacemaker Implantation in Children Weighing <10 kg.

    Science.gov (United States)

    Konta, Laura; Chubb, Mark Henry; Bostock, Julian; Rogers, Jan; Rosenthal, Eric

    2016-02-01

    Epicardial pacemaker implantation is the favored approach in children weighing pacemaker implantation in neonates and infants from 1987. To date there have been no long-term follow-up reports of what is for many a controversial strategy. Between 1987 and 2003, 37 neonates and infants-median age 6.7 months (1 day to 3 years) and median weight 4.6 kg (2.7-10 kg)-had a permanent transvenous pacing system implanted. Pacing leads were placed into the right ventricular apex/outflow tract through a subclavian vein puncture with a redundant loop in the atrium. Three patients were lost to follow-up, 4 patients died from complications of cardiac surgery, and 2 patients had their system removed. At long-term follow-up in 28 patients at a median of 17.2 (range, 11.2-27.4) years, 10 patients have a single chamber ventricular pacemaker, 14 a dual chamber pacemaker, 3 a biventricular pacemaker, and 1 has a single chamber implantable cardioverter defibrillator. Subclavian vein patency was assessed in 26 patients. The overall subclavian vein occlusion rate was 10 of 13 (77%) 5 kg during long-term follow-up. After a median of 14.3 (range, 13.4-17.6) years of pacing, 7 patients continue with their original lead. Transvenous pacing in infants <10 kg results in encouraging short- and long-term clinical outcomes. Subclavian vein occlusion remains an important complication, occurring predominantly in those weighing <5 kg. © 2016 American Heart Association, Inc.

  9. Perioperative Interrogation of St. Jude Cardiovascular Implantable Electronic Devices: A Guide for Anesthesiologists.

    Science.gov (United States)

    Cronin, Brett; Essandoh, Michael K

    2018-04-01

    Feelings of trepidation or uncertainty regarding cardiovascular implantable electronic devices (CIEDs) in the perioperative period can often be mitigated by a thorough knowledge of societal recommendations, recommended management options, and familiarity with CIEDs. Given that effective interpretation of an interrogation report is vital to determining perioperative management options and applying societal recommendations, the creation and interpretation of St. Jude CIED interrogation reports are discussed. In an effort to increase the familiarity with St. Jude transvenous CIEDs amongst anesthesiologists, basic programming of a St. Jude pacemaker and implantable cardioverter defibrillator (ICD) also are described. Published by Elsevier Inc.

  10. Heart rate variability density analysis (Dyx) for identification of appropriate implantable cardioverter defibrillator recipients among elderly patients with acute myocardial infarction and left ventricular systolic dysfunction

    DEFF Research Database (Denmark)

    Jørgensen, Rikke Mørch; Levitan, Jacob; Halevi, Zohar

    2015-01-01

    AIMS: Dyx is a new heart rate variability (HRV) density analysis specifically designed to identify patients at high risk for malignant ventricular arrhythmias. The aim of this study was to test if Dyx can improve risk stratification for malignant ventricular tachyarrhythmias and to test if the pr......AIMS: Dyx is a new heart rate variability (HRV) density analysis specifically designed to identify patients at high risk for malignant ventricular arrhythmias. The aim of this study was to test if Dyx can improve risk stratification for malignant ventricular tachyarrhythmias and to test...

  11. Prophylactic catheter ablation of ventricular tachycardia before cardioverter-defibrillator implantation in patients with non-ischemic cardiomyopathy: Clinical outcomes after a single endocardial ablation

    Directory of Open Access Journals (Sweden)

    Atsushi Suzuki, MD

    2015-06-01

    Conclusion: Single endocardial PCA can decrease ES occurrence in NICM patients. However, high rates of VT recurrence and low success rates are issues to be resolved; therefore, the efficacy of single endocardial PCA is currently limited.

  12. The CopenHeartSF trial—comprehensive sexual rehabilitation programme for male patients with implantable cardioverter defibrillator or ischaemic heart disease and impaired sexual function

    DEFF Research Database (Denmark)

    Johansen, Pernille Palm; Zwisler, Ann-Dorthe; Svendsen, Jesper Hastrup

    2013-01-01

    Sexuality is an important part of people's physical and mental health. Patients with heart disease often suffer from sexual dysfunction. Sexual dysfunction has a negative impact on quality of life and well-being in persons with heart disease, and sexual dysfunction is associated with anxiety...... and depression. Treatment and care possibilities seem to be lacking. Studies indicate that non-pharmacological interventions such as exercise training and psychoeducation possess the potential of reducing sexual dysfunction in patients with heart disease. The CopenHeartSF trial will investigate the effect...

  13. Is the epicardial left ventricular lead implantation an alternative approach to percutaneous attempt in patients with Steinert disease? A case report

    Science.gov (United States)

    PAPA, ANDREA ANTONIO; RAGO, ANNA; PETILLO, ROBERTA; D’AMBROSIO, PAOLA; SCUTIFERO, MARIANNA; FEO, MARISA DE; MAIELLO, CIRO; PALLADINO, ALBERTO

    2017-01-01

    Steinert’s disease or Myotonic Dystrophy type 1 (DM1) is an autosomal dominant multisystemic disorder characterized by myotonia, muscle and facial weakness, cataracts, cognitive, endocrine and gastrointestinal involvement, and cardiac conduction abnormalities. Although mild myocardial dysfunction may be detected in this syndrome with age, overt myocardial dysfunction with heart failure is not frequent. Cardiac resynchronization therapy is an effective treatment to improve morbidity and reduce mortality in patients with DM1 showing intra-ventricular conduction delay and/or congestive heart failure. We report the case of a patient with Steinert disease showing an early onset ventricular dysfunction due to chronic right ventricular apical pacing, in which an epicardial left ventricular lead implantation was performed following the failure of the percutaneous attempt. As no relief in symptoms of heart failure, nor an improvement of left ventricular ejection fraction and reverse remodelling was observed six months later, the patient was addressed to the heart transplantation.

  14. Utilization of YouTube as a Tool to Assess Patient Perception Regarding Implanted Cardiac Devices.

    Science.gov (United States)

    Hayes, Kevin; Mainali, Prajeena; Deshmukh, Abhishek; Pant, Sadip; Badheka, Apurva O; Paydak, Hakan

    2014-07-01

    The outreach of YouTube may have a dramatic role in the widespread dissemination of knowledge on implantable cardioverter devices (ICD). This study was designed to review and analyze the information available on YouTube pertaining to implantable cardiac devices such as implantable cardioverter defibrillators (ICDs) and pacemakers. YouTube was queried for the terms "ICD", "Implantable Cardioverter Defibrillator", and "Pacemaker". The videos were reviewed and categorized as according to content; number of views and "likes" or "dislikes" was recorded by two separate observers. Of the 55 videos reviewed, 18 of the videos were categorized as patient education, 12 were advertisements, 8 were intraoperative videos documenting the device implantation procedures, 7 of the videos were produced to document personal patient experiences, and 4 were categorized as documentation of a public event. 3 were intended to educate health care workers. The remaining 3 were intended to raise public awareness about sudden cardiac death. The videos portraying intraoperative procedures generated the most "likes" or "dislikes" per view. While YouTube provides a logical platform for delivery of health information, the information on this platform is not regulated. Initiative by reputed authorities and posting accurate information in such platform can be a great aid in public education regarding device therapy.

  15. Implant healing in experimental animal models of diabetes.

    Science.gov (United States)

    Le, Nga N; Rose, Michael B; Levinson, Howard; Klitzman, Bruce

    2011-05-01

    Diabetes mellitus is becoming increasingly prevalent worldwide. Additionally, there is an increasing number of patients receiving implantable devices such as glucose sensors and orthopedic implants. Thus, it is likely that the number of diabetic patients receiving these devices will also increase. Even though implantable medical devices are considered biocompatible by the Food and Drug Administration, the adverse tissue healing that occurs adjacent to these foreign objects is a leading cause of their failure. This foreign body response leads to fibrosis, encapsulation of the device, and a reduction or cessation of device performance. A second adverse event is microbial infection of implanted devices, which can lead to persistent local and systemic infections and also exacerbates the fibrotic response. Nearly half of all nosocomial infections are associated with the presence of an indwelling medical device. Events associated with both the foreign body response and implant infection can necessitate device removal and may lead to amputation, which is associated with significant morbidity and cost. Diabetes mellitus is generally indicated as a risk factor for the infection of a variety of implants such as prosthetic joints, pacemakers, implantable cardioverter defibrillators, penile implants, and urinary catheters. Implant infection rates in diabetic patients vary depending upon the implant and the microorganism, however, for example, diabetes was found to be a significant variable associated with a nearly 7.2% infection rate for implantable cardioverter defibrillators by the microorganism Candida albicans. While research has elucidated many of the altered mechanisms of diabetic cutaneous wound healing, the internal healing adjacent to indwelling medical devices in a diabetic model has rarely been studied. Understanding this healing process is crucial to facilitating improved device design. The purpose of this article is to summarize the physiologic factors that

  16. Electromagnetic Interference in Implantable Rhythm Devices - The Indian Scenario

    Directory of Open Access Journals (Sweden)

    Johnson Francis

    2002-07-01

    Full Text Available Implantable rhythm device (IRD is the generic name for the group of implantable devices used for diagnosis and treatment of cardiac arrhythmias. Devices in this category include cardiac pacemakers, implantable cardioverter defibrillators and implantable loop recorders. Since these devices have complex microelectronic circuitry and use electromagnetic waves for communication, they are susceptible to interference from extraneous sources of electromagnetic radiation and magnetic energy. Electromagnetic interference (EMI is generally not a major problem outside of the hospital environment. The most important interactions occur when a patient is subjected to medical procedures such as magnetic resonance imaging (MRI, electrocautery and radiation therapy. Two articles in this issue of the journal discusses various aspects of EMI on IRD1,2 . Together these articles provide a good review of the various sources of EMI and their interaction with IRD for the treating physician.

  17. Sexual concerns and practices after ICD implantation

    DEFF Research Database (Denmark)

    Kikkenborg Berg, Selina; Elleman-Jensen, Line; Zwisler, Ann-Dorthe

    2013-01-01

    given about sexual activity, (b) the areas of patient concerns related to sexual function and the ICD, and (c) changes in sexual behavior.Methods:A randomized controlled trial including 196 patients (1:1) was designed, including 12 weeks of exercise training and 1 year of psycho-educational follow......Background:Studies show that patients with implantable cardioverter defibrillators (ICD) frequently experience sexual dysfunction. These experiences are often linked to exercise intolerance, side-effects of medication, and psychological problems.Objective:To describe (a) the level of information......-up focusing on modifiable factors associated with poor outcomes, including sexual functioning. The Sex After ICD Survey was administered 6 months after the randomization as part of the planned explorative outcomes. 141 patients responded.Results:The analyses showed that 37 of the 69 (55.2%) patients...

  18. Cardioverter-Defibrillator: A Treatment for Arrhythmia

    Science.gov (United States)

    ... abdomen (stomach area). It can go in a “pocket” under your skin or in a muscle. The ... counter Products Procedures & Devices Prescription Medicines Health Tools Dictionary Symptom Checker BMI Calculator myhealthfinder Immunization Schedules Nutrient ...

  19. Defibrillator Implantation in Patients with Nonischemic Systolic Heart Failure

    DEFF Research Database (Denmark)

    Køber, Lars; Thune, Jens J; Nielsen, Jens C

    2016-01-01

    Background The benefit of an implantable cardioverter-defibrillator (ICD) in patients with symptomatic systolic heart failure caused by coronary artery disease has been well documented. However, the evidence for a benefit of prophylactic ICDs in patients with systolic heart failure that is not due...... to coronary artery disease has been based primarily on subgroup analyses. The management of heart failure has improved since the landmark ICD trials, and many patients now receive cardiac resynchronization therapy (CRT). Methods In a randomized, controlled trial, 556 patients with symptomatic systolic heart.......6%) in the control group (P=0.29). Conclusions In this trial, prophylactic ICD implantation in patients with symptomatic systolic heart failure not caused by coronary artery disease was not associated with a significantly lower long-term rate of death from any cause than was usual clinical care. (Funded by Medtronic...

  20. Electrophysiology Catheter-Facilitated coronary sinus cannulation and implantation of cardiac resynchronization therapy systems

    Directory of Open Access Journals (Sweden)

    Antonis S. Manolis, MD, FESC, FACC, FHRS

    2018-01-01

    Full Text Available Background: Cardiac resynchronization therapy (CRT device implantation is hampered by difficult placement of the left ventricular (LV lead. We have routinely used a steerable electrophysiology catheter to guide coronary sinus (CS cannulation and facilitate LV lead positioning. The aim of this prospective study is to present our results with this approach in 138 consecutive patients receiving a CRT device over 10 years. Methods: The study included 120 men and 18 women, aged 64.8±11.4 years, with coronary disease (n=63, cardiomyopathy (n=72, or other disease (n=3, and mean ejection fraction of 24.5±4.5%. Devices were implanted for refractory heart failure and dyssynchrony, all but 2 in the presence of left bundle branch block. Implanted devices included biventricular pacemakers (CRT-P (n=33 and cardioverter defibrillators (CRT-D (n=105. Results: Using the electrophysiology catheter, the CS could be engaged in 134 (97.1% patients. In 4 patients failing CS cannulation, a dual-chamber device was implanted in 2, and bifocal right ventricular pacing was effected in 2. Bifocal (n=2 or conventional (n=1 systems were implanted in another 3 patients, in whom the LV lead got dislodged (n=2 or removed because of local dissection (n=1. Thus, finally, a CRT system was successfully established in 131 (94.9% patients. There were 3 patients with CS dissection, of whom 1 was complicated by cardiac tamponade managed with pericardiocentesis. There were no perioperative deaths. During follow-up (31.0±21.2 months, clinical improvement was reported by 108 (82.4% patients. Conclusion: Routine use of an electrophysiology catheter greatly facilitated CS cannulation and successful LV lead placement in ∼95% of patients undergoing CRT system implantation. Keywords: heart failure, cardiac resynchronization therapy, implantable cardioverter defibrillator, coronary sinus, left ventricular lead

  1. Inverse Relation between Condition of Heart Failure and Intrathoracic Impedance Measured by Implantable Cardioverter Defibrillator—A case report—

    Directory of Open Access Journals (Sweden)

    Kohei Matsushita, MD

    2005-01-01

    Full Text Available The patient was a 78-year-old man with dilated cardiomyopathy. His cardio-thoracic ratio was 60.4% and left ventricular ejection fraction (LVEF was 33%. He had been repeatedly admitted for congestive heart failure. He underwent implantation of an implantable cardioverter-defibrillator (ICD for ventricular fibrillation. We compared the values of BNP and shock impedance stored by the ICD. The correlation coefficient (p-value between BNP and shock impedance was −0.700 (p < 0.0005, increase of BNP and shock impedance was −0.778 (p < 0.0001, percent increase of BNP and shock impedance was −0.767 (p < 0.0005. In conclusion, there is an inverse relation between BNP and shock impedance, and measurements of shock impedance may be useful in the management of congestive heart failure.

  2. Candida and cardiovascular implantable electronic devices: a case of lead and native aortic valve endocarditis and literature review.

    Science.gov (United States)

    Glavis-Bloom, Justin; Vasher, Scott; Marmor, Meghan; Fine, Antonella B; Chan, Philip A; Tashima, Karen T; Lonks, John R; Kojic, Erna M

    2015-11-01

    Use of cardiovascular implantable electronic devices (CIED), including permanent pacemakers (PPM) and implantable cardioverter defibrillators (ICD), has increased dramatically over the past two decades. Most CIED infections are caused by staphylococci. Fungal causes are rare and their prognosis is poor. To our knowledge, there has not been a previously reported case of multifocal Candida endocarditis involving both a native left-sided heart valve and a CIED lead. Here, we report the case of a 70-year-old patient who presented with nausea, vomiting, and generalised fatigue, and was found to have Candida glabrata endocarditis involving both a native aortic valve and right atrial ICD lead. We review the literature and summarise four additional cases of CIED-associated Candida endocarditis published from 2009 to 2014, updating a previously published review of cases prior to 2009. We additionally review treatment guidelines and discuss management of CIED-associated Candida endocarditis. © 2015 Blackwell Verlag GmbH.

  3. Implantable Medical Devices; Networking Security Survey

    Directory of Open Access Journals (Sweden)

    Siamak Aram

    2016-08-01

    Full Text Available The industry of implantable medical devices (IMDs is constantly evolving, which is dictated by the pressing need to comprehensively address new challenges in the healthcare field. Accordingly, IMDs are becoming more and more sophisticated. Not long ago, the range of IMDs’ technical capacities was expanded, making it possible to establish Internet connection in case of necessity and/or emergency situation for the patient. At the same time, while the web connectivity of today’s implantable devices is rather advanced, the issue of equipping the IMDs with sufficiently strong security system remains unresolved. In fact, IMDs have relatively weak security mechanisms which render them vulnerable to cyber-attacks that compromise the quality of IMDs’ functionalities. This study revolves around the security deficiencies inherent to three types of sensor-based medical devices; biosensors, insulin pump systems and implantable cardioverter defibrillators. Manufacturers of these devices should take into consideration that security and effectiveness of the functionality of implants is highly dependent on the design. In this paper, we present a comprehensive study of IMDs’ architecture and specifically investigate their vulnerabilities at networking interface.

  4. Critical appraisal of cardiac implantable electronic devices: complications and management

    Directory of Open Access Journals (Sweden)

    Padeletti L

    2011-09-01

    Full Text Available Luigi Padeletti1, Giosuè Mascioli2, Alessandro Paoletti Perini1, Gino Grifoni1, Laura Perrotta1, Procolo Marchese3, Luca Bontempi3, Antonio Curnis31Istituto di Clinica Medica e Cardiologia, Università degli Studi di Firenze, Italia; 2Elettrofisiologia, Istituto Humanitas Gavazzeni, Bergamo, Italia; 3Elettrofisiologia, Spedali Civili, Brescia, ItaliaAbstract: Population aging and broader indications for the implant of cardiac implantable electronic devices (CIEDs are the main reasons for the continuous increase in the use of pacemakers (PMs, implantable cardioverter-defibrillators (ICDs and devices for cardiac resynchronization therapy (CRT-P, CRT-D. The growing burden of comorbidities in CIED patients, the greater complexity of the devices, and the increased duration of procedures have led to an augmented risk of infections, which is out of proportion to the increase in implantation rate. CIED infections are an ominous condition, which often implies the necessity of hospitalization and carries an augmented risk of in-hospital death. Their clinical presentation may be either at pocket or at endocardial level, but they can also manifest themselves with lone bacteremia. The management of these infections requires the complete removal of the device and subsequent, specific, antibiotic therapy. CIED failures are monitored by competent public authorities, that require physicians to alert them to any failures, and that suggest the opportune strategies for their management. Although the replacement of all potentially affected devices is often suggested, common practice indicates the replacement of only a minority of devices, as close follow-up of the patients involved may be a safer strategy. Implantation of a PM or an ICD may cause problems in the patients' psychosocial adaptation and quality of life, and may contribute to the development of affective disorders. Clinicians are usually unaware of the psychosocial impact of implanted PMs and ICDs. The

  5. Electromagnetic interference of implantable cardiac devices from a shoulder massage machine.

    Science.gov (United States)

    Yoshida, Saeko; Fujiwara, Kousaku; Kohira, Satoshi; Hirose, Minoru

    2014-09-01

    Shoulder massage machines have two pads that are driven by solenoid coils to perform a per cussive massage on the shoulders. There have been concerns that such machines might create electromagnetic interference (EMI) in implantable cardiac devices because of the time-varying magnetic fields produced by the alternating current in the solenoid coils. The objective of this study was to investigate the potential EMI from one such shoulder massage machine on implantable cardiac devices. We measured the distribution profile of the magnetic field intensity around the massage machine. Furthermore, we performed an inhibition test and an asynchronous test on an implantable cardiac pacemaker using the standardized Irnich human body model. We examined the events on an implantable cardioverter-defibrillator (ICD) using a pacemaker programmer while the massage machine was in operation. The magnetic field distribution profile exhibited a peak intensity of 212 (A/m) in one of the solenoid coils. The maximal interference distance between the massage machine and the implantable cardiac pacemaker was 28 cm. Ventricular fibrillation was induced when the massage machine was brought near the electrode of the ICD and touched the Irnich human body model. It is necessary to provide a "don't use" warning on the box or the exterior of the massage machines or in the user manuals and to caution patients with implanted pacemakers about the dangers and appropriate usage of massage machines.

  6. [Electrical storm in patients with prophylactic defibrillator implantation].

    Science.gov (United States)

    Rodríguez-Mañero, Moisés; González-Cambeiro, Cristina; Moreno-Arribas, Jose; Expósito-García, Víctor; Sánchez-Gómez, Juan Miguel; González-Torres, Luis; Arce-León, Álvaro; Arguedas-Jiménez, Hugo; Gaztañaga, Larraitz; Salvador-Montañés, Oscar; Iglesias-Bravo, Jose Antonio; Huerta, Ana Andrés La; Fernández-Armenta, Juan; Arias, Miguel Ángel; Martínez-Sande, Luis

    2016-01-01

    Little is known about the prevalence of electrical storm, baseline characteristics and mortality implications of patients with implantable cardioverter defibrillator in primary prevention versus those patients without electrical storm. We sought to assess the prevalence, baseline risk profile and survival significance of electrical storm in patients with implantable defibrillator for primary prevention. Retrospective multicenter study performed in 15 Spanish hospitals. Consecutives patients referred for desfibrillator implantation, with or without left ventricular lead (at least those performed in 2010 and 2011), were included. Over all 1,174 patients, 34 (2,9%) presented an electrical storm, mainly due to ventricular tachycardia (82.4%). There were no significant baseline differences between groups, with similar punctuation in the mortality risk scores (SHOCKED, MADIT and FADES). A clear trigger was identified in 47% of the events. During the study period (38±21 months), long-term total mortality (58.8% versus 14.4%, pstorm patients. Rate of inappropriate desfibrillator intervention was also higher (14.7 versus 8.6%, pstorm was 2.9%. There were no baseline differences in the cardiovascular risk profile versus those without electrical storm. However, all cause mortality and cardiovascular mortality was increased in these patients versus control desfibrillator patients without electrical storm, as was the rate of inappropriate desfibrillator intervention. Copyright © 2015 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  7. Determinants of geographic variations in implantation of cardiac defibrillators in the European Society of Cardiology member countries--data from the European Heart Rhythm Association White Book.

    Science.gov (United States)

    Lubinski, Andrzej; Bissinger, Andrzej; Boersma, Lucas; Leenhardt, Antoine; Merkely, Bela; Oto, Ali; Proclemer, Alessandro; Brugada, Josep; Vardas, Panos E; Wolpert, Christian

    2011-05-01

    Sudden cardiac death (SCD) is a major health concern in developed countries. Many studies have demonstrated the efficacy of implantable cardioverter defibrillator (ICD) therapy in the prevention of SCD and total mortality reduction. However, the high individual costs and the reimbursement policy may limit widespread ICD utilization. This study analyzed the temporal and the geographical trends of the ICD implantation rate. Data were gathered from two editions of the European Heart Rhythm Association (EHRA) White Books published in 2008 and 2009. The analysis revealed significant differences in the rates of ICD implantation per million capita between the countries, but the median implantations was constantly increasing. The number of ICD implantations correlated with gross domestic product (GDP), GDP per capita, expenditure on health, life expectancy, and the number of implanting centres. There are great number of differences in the ICD-implanting rates between EHRA member countries, consequent to the increase in the number of ICD implantations. The ICD implantation rates are related to national economic status and healthcare expenses.

  8. Active implantable medical device EMI assessment for wireless power transfer operating in LF and HF bands.

    Science.gov (United States)

    Hikage, Takashi; Nojima, Toshio; Fujimoto, Hiroshi

    2016-06-21

    The electromagnetic interference (EMI) imposed on active implantable medical devices by wireless power transfer systems (WPTSs) is discussed based upon results of in vitro experiments. The purpose of this study is to present comprehensive EMI test results gathered from implantable-cardiac pacemakers and implantable cardioverter defibrillators exposed to the electromagnetic field generated by several WPTSs operating in low-frequency (70 kHz-460 kHz) and high-frequency (6.78 MHz) bands. The constructed in vitro experimental test system based upon an Irnich's flat torso phantom was applied. EMI test experiments are conducted on 14 types of WPTSs including Qi-compliant system and EV-charging WPT system mounted on current production EVs. In addition, a numerical simulation model for active implantable medical device (AIMD) EMI estimation based on the experimental test system is newly proposed. The experimental results demonstrate the risk of WPTSs emitting intermittent signal to affect the correct behavior of AIMDs when operating at very short distances. The proposed numerical simulation model is applicable to obtain basically the EMI characteristics of various types of WPTSs.

  9. Ventricular Tachycardia Detected by Implantable Loop Recorder in a Child with Recurrent Syncope

    Directory of Open Access Journals (Sweden)

    İsa Özyılmaz

    2014-06-01

    Full Text Available In this article, we present a 10-year-old boy who was admitted to the hospital with recurrent syncope. There was no remarkable finding in patient’s physical examination, family history, and the diagnostic 12-lead electrocardiogram (ECG, chest x-ray, ECG Holter monitoring, event recording, echocardiography, coronary computed tomography (CT angiography, Ajmaline test for the diagnosis of Brugada syndrome, brain magnetic resonance imaging, and sleep/wake electroencephalogram. We started beta-blocker therapy because the patient had exercise-induced syncope. An Implantable loop recorder (ILR was inserted to the patient. Three years later, polymorphic ventricular tachycardia called torsades de pointes was detected by the ILR during syncope occurred with exercise. The patient had been taking high-dose betablocker treatment, an implantable cardioverter defibrillator was implanted into the patient. ILR can play an important role in the diagnosis of life-threatening arrhythmia in children with unexplained syncope. (The Me­di­cal Bul­le­tin of Ha­se­ki 2014; 52: 123-5

  10. Canadian Registry of ICD Implant Testing procedures (CREDIT): current practice, risks, and costs of intraoperative defibrillation testing.

    Science.gov (United States)

    Healey, Jeff S; Dorian, Paul; Mitchell, L Brent; Talajic, Mario; Philippon, Francois; Simpson, Chris; Yee, Raymond; Morillo, Carlos A; Lamy, Andre; Basta, Magdy; Birnie, David H; Wang, Xiaoyin; Nair, Girish M; Crystal, Eugene; Kerr, Charles R; Connolly, Stuart J

    2010-02-01

    There is uncertainty about the proper role of defibrillation testing (DT) at the time of implantable cardioverter defibrillator (ICD) insertion. A prospective registry was conducted at 13 sites in Canada between January 2006 and October 2007. To document the details of DT, the reasons for not conducting DT, and the costs and complications associated with DT. DT was conducted at implantation in 230 of 361 patients (64%). DT was more likely to be conducted for new implants compared with impulse generator replacements (71% vs 32%, P = 0.0001), but was similar for primary and secondary prevention indications (64% vs 63%, P = NS). Among patients not having DT, the reason(s) given were: considered unnecessary (44%); considered unsafe, mainly due to persistent atrial fibrillation (37%); lack of an anesthetist (20%); and, patient or physician preference (6%). When performed, DT consisted of a single successful shock > or = 10J below maximum device output in 65% of cases. A 10J safety-margin was met by 97% of patients, requiring system modification in 2.3%. Major perioperative complications occurred in 4.4% of patients having DT versus 6.6% of patients not having DT (P = NS). ICD insertion was $844 more expensive for patients having DT (P = 0.16), largely due to increased costs ($28,017 vs $24,545) among patients having impulse generator replacement (P = 0.02). DT was not performed in a third of ICD implants, usually due to a perceived lack of need or relative contraindication.

  11. Patient benefit from seamless implant monitoring

    Directory of Open Access Journals (Sweden)

    Karsten Wallbrück

    2005-12-01

    Full Text Available Background: Patients with electrostimulation devices visit the hospital regularly for follow-up. The workload of out-patient departments is ever increasing, but a less frequent check-up is unwanted, as it could impair reliability and effectiveness of the therapy. A system of remote patient monitoring might improve this situation by enabling identification of patients who benefit from a shortened time for corrective action after any undesired event. A completely automatic system for patient remote monitoring has been introduced (BIOTRONIK Home Monitoring, HM. Daily patient and device data are displayed on an internet site which allows authorized persons to follow the parameters trends. Several clinical studies are presently being conducted to investigate the benefit of HM in pacemaker and implantable cardioverter/defibrillator therapy. Preliminary results show the system’s ability to individualize implant therapy for the patients’ and the physicians’ benefits. Previous studies in heart failure (HF therapy have shown that hospital readmission rates, hospitalisation duration and also mortality can be reduced by patient monitoring programs. A recently started study investigating HM in heart failure therapy aims to define a HF-indicator that predicts a worsening of the patient’s status leading to hospitalisation. With such an indicator, the responsible physician could be alerted and the patient can be called in. Although several issues connected to Home Monitoring remain to be solved, the time has come for a more flexible patient management. The incorporation of modern information technology into cardiovascular implants offers a way to solve the conflict between limited resources and high quality medical therapy for an aging population.

  12. Catheter ablation of epicardial ventricular tachycardia

    Directory of Open Access Journals (Sweden)

    Takumi Yamada, MD, PhD

    2014-08-01

    Full Text Available Ventricular tachycardias (VTs can usually be treated by endocardial catheter ablation. However, some VTs can arise from the epicardial surface, and their substrate can be altered only by epicardial catheter ablation. There are two approaches to epicardial catheter ablation: transvenous and transthoracic. The transvenous approach through the coronary venous system (CVS has been commonly used because it is easily accessible. However, this approach may be limited by the distribution of the CVS and insufficient radiofrequency energy delivery. Transthoracic epicardial catheter ablation has been developed to overcome these limitations of the transvenous approach. It is a useful supplemental or even preferred strategy to eliminate epicardial VTs in the electrophysiology laboratory. This technique has been applied for scar-related VTs secondary to often non-ischemic cardiomyopathy and sometimes ischemic cardiomyopathy, and idiopathic VTs as the epicardial substrates of these VTs have become increasingly recognized. When endocardial ablation and epicardial ablation through the CVS are unsuccessful, transthoracic epicardial ablation should be the next option. Intrapericardial access is usually obtained through a subxiphoidal pericardial puncture. This approach might not be possible in patients with pericardial adhesions caused by prior cardiac surgery or pericarditis. In such cases, a hybrid procedure involving surgical access with a subxiphoid pericardial window and a limited anterior or lateral thoracotomy might be a feasible and safe method of performing an epicardial catheter ablation in the electrophysiology laboratory. Potential complications associated with this technique include bleeding and collateral damage to the coronary arteries and phrenic nerve. Although the risk of these complications is low, electrophysiologists who attempt epicardial catheter ablation should know the complications associated with this technique, how to minimize their

  13. Implanted near-infrared spectroscopy for cardiac monitoring

    Science.gov (United States)

    Bhunia, Sourav K.; Cinbis, Can

    2011-02-01

    Implanted Cardioverter Defibrillator (ICD) provides one of the most effective therapies for the prevention of sudden cardiac death, but also delivers some high voltage shocks inappropriately, causing morbidity and mortality. Implanted near-infrared spectroscopy (NIRS) may augment ICD arrhythmia detection by monitoring skeletal muscle perfusion. A two-wavelength, single-distance, continuous-wave implanted NIRS has been evaluated in-vivo. A weighted difference of the changes in attenuation at two wavelengths, across the isobestic point of the hemoglobin spectra, was taken to be the microvascular oxygenation trend indicator (O2 Index). Although the exact weight depends on the local vascular distribution and their oxygen levels, the hypothesis that a constant weight may be adequate for hemodynamic trending during short arrhythmic episodes, was tested. The sensor was implanted subcutaneously both on fresh tissue and inside scar tissue that formed around a pre-existing implant, in 3 animals each. Attenuations were recorded at 660 and 890 nm during normal sinus rhythm (NSR) and induced ventricular fibrillation (VF). The slope of the O2 Index over 10 seconds was computed for 7 NSR and 8 VF episodes in fresh and 13 NSR and 15 VF episodes in scar tissue pockets. The mean O2 Index slope was significantly different (p<0.0001) between NSR and VF rhythms for both the fresh and scar tissue pockets. Therefore implanted NIRS may be useful for preventing inappropriate detection of VF during electromagnetic interference, double counting of ECG T-wave as an R-wave, ICD lead failure, electrocardiographic aberrancy etc.

  14. DEGRO/DGK guideline for radiotherapy in patients with cardiac implantable electronic devices

    International Nuclear Information System (INIS)

    Gauter-Fleckenstein, Benjamin; Steil, Volker; Wenz, Frederik; Israel, Carsten W.; Dorenkamp, Marc; Dunst, Juergen; Roser, Mattias; Schimpf, Rainer; Schaefer, Joerg; Hoeller, Ulrike

    2015-01-01

    An increasing number of patients undergoing radiotherapy (RT) have cardiac implantable electronic devices [CIEDs, cardiac pacemakers (PMs) and implanted cardioverters/defibrillators (ICDs)]. Ionizing radiation can cause latent and permanent damage to CIEDs, which may result in loss of function in patients with asystole or ventricular fibrillation. Reviewing the current literature, the interdisciplinary German guideline (DEGRO/DGK) was developed reflecting patient risk according to type of CIED, cardiac condition, and estimated radiation dose to the CIED. Planning for RT should consider the CIED specifications as well as patient-related characteristics (pacing-dependent, previous ventricular tachycardia/fibrillation). Antitachyarrhythmia therapy should be suspended in patients with ICDs, who should be under electrocardiographic monitoring with an external defibrillator on stand-by. The beam energy should be limited to 6 (to 10) MV CIEDs should never be located in the beam, and the cumulative scatter radiation dose should be limited to 2 Gy. Personnel must be able to respond adequately in the case of a cardiac emergency and initiate basic life support, while an emergency team capable of advanced life support should be available within 5 min. CIEDs need to be interrogated 1, 3, and 6 months after the last RT due to the risk of latent damage. (orig.) [de

  15. Remote monitoring of implantable cardiac devices: current state and future directions.

    Science.gov (United States)

    Ganeshan, Raj; Enriquez, Alan D; Freeman, James V

    2018-01-01

    Recent evidence has demonstrated substantial benefits associated with remote monitoring of cardiac implantable electronic devices (CIEDs), and treatment guidelines have endorsed the use of remote monitoring. Familiarity with the features of remote monitoring systems and the data supporting its use are vital for physicians' care for patients with CEIDs. Remote monitoring remains underutilized, but its use is expanding including in new practice settings including emergency departments. Patient experience and outcomes are positive, with earlier detection of clinical events such as atrial fibrillation, reductions in inappropriate implantable cardioverter-defibrillator (ICD) shocks and potentially a decrease in mortality with frequent remote monitoring utilizaiton. Rates of hospitalization are reduced among remote monitoring users, and the replacement of outpatient follow-up visits with remote monitoring transmissions has been shown to be well tolerated. In addition, health resource utilization is lower and remote monitoring has been associated with considerable cost savings. A dose relationship exists between use of remote monitoring and patient outcomes, and those with early and high transmission rates have superior outcomes. Remote monitoring provides clinicians with the ability to provide comprehensive follow-up care for patients with CIEDs. Patient outcomes are improved, and resource utilization is decreased with appropriate use of remote monitoring. Future efforts must focus on improving the utilization and efficiency of remote monitoring.

  16. Radiographic implications of procedures involving cardiac implantable electronic devices (CIEDs – Selected aspects

    Directory of Open Access Journals (Sweden)

    Roman Steckiewicz

    2017-06-01

    Full Text Available Background: Some cardiac implantable electronic device (CIED implantation procedures require the use of X-rays, which is reflected by such parameters as total fluoroscopy time (TFT and dose-area product (DAP – defined as the absorbed dose multiplied by the area irradiated. Material and Methods: This retrospective study evaluated 522 CIED implantation (424 de novo and 98 device upgrade and new lead placement procedures in 176 women and 346 men (mean age 75±11 years over the period 2012–2015. The recorded procedure-related parameters TFT and DAP were evaluated in the subgroups specified below. The group of 424 de novo procedures included 203 pacemaker (PM and 171 implantable cardioverter-defibrillator (ICD implantation procedures, separately stratified by single-chamber and dual-chamber systems. Another subgroup of de novo procedures involved 50 cardiac resynchronization therapy (CRT devices. The evaluated parameters in the group of 98 upgrade procedures were compared between 2 subgroups: CRT only and combined PM and ICD implantation procedures. Results: We observed differences in TFT and DAP values between procedure types, with PM-related procedures showing the lowest, ICD – intermediate (with values for single-chamber considerably lower than those for dual-chamber systems and CRT implantation procedures – highest X-ray exposure. Upgrades to CRT were associated with 4 times higher TFT and DAP values in comparison to those during other upgrade procedures. Cardiac resynchronization therapy de novo implantation procedures and upgrades to CRT showed similar mean values of these evaluated parameters. Conclusions: Total fluoroscopy time and DAP values correlated progressively with CIED implantation procedure complexity, with CRT-related procedures showing the highest values of both parameters. Med Pr 2017;68(3:363–374

  17. Electrical storm in patients with an implanted defibrillator: a matter of definition.

    Science.gov (United States)

    Israel, Carsten W; Barold, S Serge

    2007-10-01

    The term "electrical storm" (ES) indicates a state of cardiac electrical instability manifested by several episodes of ventricular tachyarrhythmias (VTs) within a short time. In patients with an implantable cardioverter defibrillator (ICD), ES is best defined as 3 appropriate VT detections in 24 h, treated by antitachycardia pacing, shock or eventually untreated but sustained in a VT monitoring zone. The number of shocks and inappropriate detections are irrelevant for the definition. ES occurs in approximately 25% of ICD patients within 3 years, with typically 5-55 individual VTs within one storm. Potential triggers can be found in approximately 66% of patients and include new/worsened heart failure, changes in antiarrhythmic medication, context with other illness, psychological stress, diarrhea, and hypokalemia. In most patients, ES consists of monomorphic VT indicating the presence of reentry while ventricular fibrillation indicating acute ischemia is rare. ES seems to have a low immediate mortality (1%) but frequently (50-80%) leads to hospitalization. Long-term prognostic implications of ES are unclear. The key intervention in ES is reduction of the elevated sympathetic tone by beta blockers and frequently benzodiazepines. Amiodarone i.v. has also been successful and azimilide seems promising while class I antiarrhythmic drugs are usually unsuccessful. Substrate mapping and VT ablation may be useful in treatment and prevention of ES. Prevention of ES requires ICD programming systematically avoiding unnecessary shocks (long VT detection, antitachycardia pacing where ever possible) which otherwise can fuel the sympathetic tone and prolong ES.

  18. An International External Validation Study of the 2014 European Society of Cardiology Guideline on Sudden Cardiac Death Prevention in Hypertrophic Cardiomyopathy (Evidence from HCM)

    DEFF Research Database (Denmark)

    O'Mahony, Constantinos; Jichi, Fatima; Ommen, Steve R

    2018-01-01

    Background -Identification of people with hypertrophic cardiomyopathy (HCM) who are at risk of sudden cardiac death (SCD) and require prophylactic implantable cardioverter defibrillator (ICD) is challenging. In 2014, the European Society of Cardiology (ESC) proposed a new risk stratification meth...

  19. The Post-Myocardial Infarction Pacing Remodeling Prevention Therapy (PRomPT) Trial

    DEFF Research Database (Denmark)

    Chung, Eugene S; Fischer, Trent M; Kueffer, Fred

    2015-01-01

    BACKGROUND: Despite considerable improvements in the medical management of patients with myocardial infarction (MI), patients with large MI still have substantial risk of developing heart failure. In the early post-MI setting, implantable cardioverter defibrillators have reduced arrhythmic deaths...

  20. Co-constructing IT and Healthcare

    DEFF Research Database (Denmark)

    Andersen, Tariq Osman; Bansler, Jørgen P.; Bjørn, Pernille

    The CITH project (Co-constructing IT and Healthcare) is an ongoing 4-year interdisciplinary research project, which investigates while intervenes in the collaborative practices involved in disease management of chronic heart patients with an ICD (Implantable Cardioverter Defibrillator)....

  1. Value of Serial Heart Rate Variability Measurement for Prediction of Appropriate ICD Discharge in Patients with Heart Failure

    NARCIS (Netherlands)

    ten Sande, Judith N.; Damman, Peter; Tijssen, Jan G. P.; de Groot, Joris R.; Knops, Reinoud E.; Wilde, Arthur A. M.; van Dessel, Pascal F. H. M.

    2014-01-01

    HRV and Appropriate ICD Shock in Heart Failure Introduction Decreased heart rate variability (HRV) is associated with adverse outcomes in patients with heart failure. Our objective was to examine whether decreased HRV predicts appropriate implantable cardioverter defibrillator (ICD) shocks. Methods

  2. Pathogenesis of sudden unexpected death in a clinical trial of patients with myocardial infarction and left ventricular dysfunction, heart failure, or both

    DEFF Research Database (Denmark)

    Pouleur, Anne-Catherine; Barkoudah, Ebrahim; Uno, Hajime

    2010-01-01

    The frequency of sudden unexpected death is highest in the early post-myocardial infarction (MI) period; nevertheless, 2 recent trials showed no improvement in mortality with early placement of an implantable cardioverter-defibrillator after MI....

  3. Prognostic value of tissue Doppler imaging for predicting ventricular arrhythmias and cardiovascular mortality in ischaemic cardiomyopathy

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Olsen, Flemming Javier; Storm, Katrine

    2016-01-01

    AIMS: Only 30% of patients receiving an implantable cardioverter defibrillator (ICD) for primary prevention receive appropriately therapy. We sought to investigate the value of tissue Doppler imaging (TDI) to predict ventricular tachycardia (VT), ventricular fibrillation (VF), and cardiovascular...

  4. Therapeutic options in chronic heart failure. Findings on chest X-ray; Nicht medikamentoese Therapieoptionen der chronischen Herzinsuffizienz. Befunde in der Projektionsradiografie des Thorax

    Energy Technology Data Exchange (ETDEWEB)

    Granitz, M.R.; Meissnitzer, T.; Meissnitzer, M.W.; Hergan, K.; Altenberger, J.; Granitz, C. [Uniklinikum Salzburg - Landeskrankenhaus (Austria)

    2016-05-15

    The contribution covers drugless therapeutic options for chronic heart failure: the implantable cardioverter/defibrillator (ICD), the cardiac resynchronization therapy (CRT), the interventional catheter treatment of functional mitral insufficiency, and mechanical heart supporting systems and heart transplantation.

  5. Therapeutic options in chronic heart failure. Findings on chest X-ray

    International Nuclear Information System (INIS)

    Granitz, M.R.; Meissnitzer, T.; Meissnitzer, M.W.; Hergan, K.; Altenberger, J.; Granitz, C.

    2016-01-01

    The contribution covers drugless therapeutic options for chronic heart failure: the implantable cardioverter/defibrillator (ICD), the cardiac resynchronization therapy (CRT), the interventional catheter treatment of functional mitral insufficiency, and mechanical heart supporting systems and heart transplantation.

  6. Elektrokirurgi hos patienter med pacemaker og implanterbar kardioverter-defibrillator

    DEFF Research Database (Denmark)

    Lønnberg, Ann Sophie Claire; Philberts, Berit Thornvig; Bonde, Christian

    2017-01-01

    Electrosurgery is a very useful tool and one of the most commonly used techniques. However, the technique can interfere with pacemakers and implantable cardioverter defibrillators. This article provides practical recommendations for the use of electrosurgery in these patients.......Electrosurgery is a very useful tool and one of the most commonly used techniques. However, the technique can interfere with pacemakers and implantable cardioverter defibrillators. This article provides practical recommendations for the use of electrosurgery in these patients....

  7. The quantitative assessment of epicardial fat distribution on human hearts: Implications for epicardial electrophysiology.

    Science.gov (United States)

    Mattson, Alexander R; Soto, Mario J; Iaizzo, Paul A

    2018-07-01

    Epicardial electrophysiological procedures rely on dependable interfacing with the myocardial tissue. For example, epicardial pacing systems must generate sustainable chronic pacing capture, while epicardial ablations must effectively deliver energy to the target hyper-excitable myocytes. The human heart has a significant adipose layer which may impede epicardial procedures. The objective of this study was to quantitatively assess the relative location of epicardial adipose on the human heart, to define locations where epicardial therapies might be performed successfully. We studied perfusion-fixed human hearts (n = 105) in multiple isolated planes including: left ventricular margin, diaphragmatic surface, and anterior right ventricle. Relative adipose distribution was quantitatively assessed via planar images, using a custom-generated image analysis algorithm. In these specimens, 76.7 ± 13.8% of the left ventricular margin, 72.7 ± 11.3% of the diaphragmatic surface, and 92.1 ± 8.7% of the anterior right margin were covered with superficial epicardial adipose layers. Percent adipose coverage significantly increased with age (P history of coronary artery disease (P history of hypertension, and/or history of congestive heart failure. Additionally, we describe two-dimensional probability distributions of epicardial adipose coverage for each of the three analysis planes. In this study, we detail the quantitative assessment and probabilistic mapping of the distribution of superficial epicardial adipose on the adult human heart. These findings have implications relative to performing epicardial procedures and/or designing procedures or tools to successfully perform such treatments. Clin. Anat. 31:661-666, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  8. Superior Rhythm Discrimination With the SmartShock Technology Algorithm - Results of the Implantable Defibrillator With Enhanced Features and Settings for Reduction of Inaccurate Detection (DEFENSE) Trial.

    Science.gov (United States)

    Oginosawa, Yasushi; Kohno, Ritsuko; Honda, Toshihiro; Kikuchi, Kan; Nozoe, Masatsugu; Uchida, Takayuki; Minamiguchi, Hitoshi; Sonoda, Koichiro; Ogawa, Masahiro; Ideguchi, Takeshi; Kizaki, Yoshihisa; Nakamura, Toshihiro; Oba, Kageyuki; Higa, Satoshi; Yoshida, Keiki; Tsunoda, Soichi; Fujino, Yoshihisa; Abe, Haruhiko

    2017-08-25

    Shocks delivered by implanted anti-tachyarrhythmia devices, even when appropriate, lower the quality of life and survival. The new SmartShock Technology ® (SST) discrimination algorithm was developed to prevent the delivery of inappropriate shock. This prospective, multicenter, observational study compared the rate of inaccurate detection of ventricular tachyarrhythmia using the SST vs. a conventional discrimination algorithm.Methods and Results:Recipients of implantable cardioverter defibrillators (ICD) or cardiac resynchronization therapy defibrillators (CRT-D) equipped with the SST algorithm were enrolled and followed up every 6 months. The tachycardia detection rate was set at ≥150 beats/min with the SST algorithm. The primary endpoint was the time to first inaccurate detection of ventricular tachycardia (VT) with conventional vs. the SST discrimination algorithm, up to 2 years of follow-up. Between March 2012 and September 2013, 185 patients (mean age, 64.0±14.9 years; men, 74%; secondary prevention indication, 49.5%) were enrolled at 14 Japanese medical centers. Inaccurate detection was observed in 32 patients (17.6%) with the conventional, vs. in 19 patients (10.4%) with the SST algorithm. SST significantly lowered the rate of inaccurate detection by dual chamber devices (HR, 0.50; 95% CI: 0.263-0.950; P=0.034). Compared with previous algorithms, the SST discrimination algorithm significantly lowered the rate of inaccurate detection of VT in recipients of dual-chamber ICD or CRT-D.

  9. Implementation and reimbursement of remote monitoring for cardiac implantable electronic devices in Europe: a survey from the health economics committee of the European Heart Rhythm Association.

    Science.gov (United States)

    Mairesse, Georges H; Braunschweig, Frieder; Klersy, Katherine; Cowie, Martin R; Leyva, Francisco

    2015-05-01

    Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) permits early detection of arrhythmias, device, and lead failure and may also be useful in risk-predicting patient-related outcomes. Financial benefits for patients and healthcare organizations have also been shown. We sought to assess the implementation and funding of RM of CIEDs, including conventional pacemakers (PMs), implantable cardioverter defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices in Europe. Electronic survey from 43 centres in 15 European countries. In the study sample, RM was available in 22% of PM patients, 74% of ICD patients, and 69% of CRT patients. The most significant perceived benefits were the early detection of atrial arrhythmias in pacemaker patients, lead failure in ICD patients, and worsening heart failure in CRT patients. Remote monitoring was reported to lead a reduction of in-office follow-ups for all devices. The most important reported barrier to the implementation of RM for all CIEDs was lack of reimbursement (80% of centres). Physicians regard RM of CIEDs as a clinically useful technology that affords significant benefits for patients and healthcare organizations. Remote monitoring, however, is perceived as increasing workload. Reimbursement for RM is generally perceived as a major barrier to implementation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  10. Dual- vs. single-chamber defibrillators for primary prevention of sudden cardiac death: long-term follow-up of the Défibrillateur Automatique Implantable-Prévention Primaire registry.

    Science.gov (United States)

    Defaye, Pascal; Boveda, Serge; Klug, Didier; Beganton, Frankie; Piot, Olivier; Narayanan, Kumar; Périer, Marie-Cécile; Gras, Daniel; Fauchier, Laurent; Bordachar, Pierre; Algalarrondo, Vincent; Babuty, Dominique; Deharo, Jean-Claude; Leclercq, Christophe; Marijon, Eloi; Sadoul, Nicolas

    2017-09-01

    Implantable cardioverter defibrillators (ICDs) are an effective primary prevention of sudden cardiac death. We examined whether dual-chamber (DC) ICDs confer a greater benefit than single-chamber (SC) ICDs, and compared the long-term outcomes of recipients of each type of device implanted for primary prevention. Between 2002 and 2012, the DAI-PP registry consecutively enrolled 1258 SC- and 1280 DC-ICD recipients at 12 French medical centres. The devices were interrogated at 4- to 6-month intervals during outpatient visits, with a focus on the therapies delivered. The study endpoints were incidence of appropriate therapies, ICD-related morbidity, and deaths from all and from specific causes. The mean age of the SC- and DC-ICD recipients was 59 ± 12 and 62 ± 11 years, respectively (PDC- vs. 8.8% in the SC-ICD groups (P= 0.008). Over a mean follow-up of 3.1 ± 2.2 years, pulse generators were replaced in 21.9% of the DC- vs. 13.6% of the SC-ICD group (PDC-ICDs were associated with higher rates of peri-implant complications and generator replacements, whereas the survival and rates of inappropriate shocks were similar in both groups. NCT#01992458. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions please email: journals.permissions@oup.com.

  11. Electrical storm is an independent predictor of adverse long-term outcome in the era of implantable defibrillator therapy.

    Science.gov (United States)

    Gatzoulis, Konstantinos A; Andrikopoulos, George K; Apostolopoulos, Theodoros; Sotiropoulos, Elias; Zervopoulos, George; Antoniou, John; Brili, Stella; Stefanadis, Christodoulos I

    2005-03-01

    Electrical storm (ES) is a life-threatening arrhythmia complication affecting patients treated with an implantable cardioverter defibrillator (ICD). Despite its increasing importance, existing data on prognosis and management of ICD patients affected by ES are limited and conflicting. We prospectively studied 169 consecutive patients receiving an ICD. Thirty-two patients presented with at least one episode of ES during the period of observation (33+/-26 months). ES patients were older (64+/-9 vs. 59+/-13 years, P=0.013) with more advanced congestive heart failure (CHF) but a similar incidence of an underlying organic heart disease. Long-term total and cardiac mortality were both increased among ES patients. Seventeen of the 32 ES patients died as opposed to 19 of the 137 ICD patients without ES (53 vs. 14%, P<0.001). In multivariate Cox regression analysis adjusted for the main confounders, history of ES was significantly and independently associated with total and cardiac mortality (risk ratio (RR)=2.13, P=0.031 and RR=2.59, P=0.019, respectively). ES is a relatively frequent complication affecting ICD patients treated for secondary prevention of sudden cardiac death (SCD). Although the acute management of this serious arrhythmia complication is usually successful, occurrence of ES is a strong independent predictor of poor outcome in ICD patients.

  12. Minimally Invasive Catheter Procedures to Assist Complicated Pacemaker Lead Extraction and Implantation in the Operating Room

    International Nuclear Information System (INIS)

    Kröpil, Patric; Lanzman, Rotem S.; Miese, Falk R.; Blondin, Dirk; Winter, Joachim; Scherer, Axel; Fürst, Günter

    2011-01-01

    We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 ± 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thus required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.

  13. Wireless microsensor network solutions for neurological implantable devices

    Science.gov (United States)

    Abraham, Jose K.; Whitchurch, Ashwin; Varadan, Vijay K.

    2005-05-01

    trigger the feed back system or contact a point-of-care office that can remotely control the implantable system. The remote monitoring technology can be adaptable to EEG monitoring of children with epilepsy, implantable cardioverters/defibrillators, pacemakers, chronic pain management systems, treatment for sleep disorders, patients with implantable devices for diabetes. In addition, the development of a wireless neural electronics interface to detect, transmit and analyze neural signals could help patients with spinal injuries to regain some semblance of mobile activity.

  14. Epicardial adipose tissue in endocrine and metabolic diseases.

    Science.gov (United States)

    Iacobellis, Gianluca

    2014-05-01

    Epicardial adipose tissue has recently emerged as new risk factor and active player in metabolic and cardiovascular diseases. Albeit its physiological and pathological roles are not completely understood, a body of evidence indicates that epicardial adipose tissue is a fat depot with peculiar and unique features. Epicardial fat is able to synthesize, produce, and secrete bioactive molecules which are then transported into the adjacent myocardium through vasocrine and/or paracrine pathways. Based on these evidences, epicardial adipose tissue can be considered an endocrine organ. Epicardial fat is also thought to provide direct heating to the myocardium and protect the heart during unfavorable hemodynamic conditions, such as ischemia or hypoxia. Epicardial fat has been suggested to play an independent role in the development and progression of obesity- and diabetes-related cardiac abnormalities. Clinically, the thickness of epicardial fat can be easily and accurately measured. Epicardial fat thickness can serve as marker of visceral adiposity and visceral fat changes during weight loss interventions and treatments with drugs targeting the fat. The potential of modulating the epicardial fat with targeted pharmacological agents can open new avenues in the pharmacotherapy of endocrine and metabolic diseases. This review article will provide Endocrine's reader with a focus on epicardial adipose tissue in endocrinology. Novel, established, but also speculative findings on epicardial fat will be discussed from the unexplored perspective of both clinical and basic Endocrinologist.

  15. First Case of Trichoderma longibrachiatum CIED (Cardiac Implantable Electronic Device)-Associated Endocarditis in a Non-immunocompromised Host: Biofilm Removal and Diagnostic Problems in the Light of the Current Literature.

    Science.gov (United States)

    Tascini, Carlo; Cardinali, Gianluigi; Barletta, Valentina; Di Paolo, Antonello; Leonildi, Alessandro; Zucchelli, Giulio; Corte, Laura; Colabella, Claudia; Roscini, Luca; Consorte, Augusta; Pasticci, Maria Bruna; Menichetti, Francesco; Bongiorni, Maria Grazia

    2016-04-01

    Trichoderma species are saprophytic filamentous fungi producing localized and invasive infections that are cause of morbidity and mortality, especially in immunocompromised patients, causing up to 53% mortality. Non-immunocompromised patients, undergoing continuous ambulatory peritoneal dialysis, are other targets of this fungus. Current molecular diagnostic tools, based on the barcode marker ITS, fail to discriminate these fungi at the species level, further increasing the difficulty associated with these infections and their generally poor prognosis. We report on the first case of endocarditis infection caused by Trichoderma longibrachiatum in a 30-year-old man. This patient underwent the implantation of an implantable cardioverter defibrillator in 2006, replaced in 2012. Two years later, the patient developed fever, treated successfully with amoxicillin followed by ciprofloxacin, but an echocardiogram showed large vegetation onto the ventricular lead. After CIED extraction, the patient had high-grade fever. The culturing of the catheter tip was positive only in samples deriving from sonication according to the 2014 ESCMID guidelines, whereas the simple washing failed to remove the biofilm cells from the plastic surface. Subsequent molecular (ITS sequencing) and microbiological (macromorphology) analyses showed that the vegetation was due to T. longibrachiatum. This report showed that T. longibrachiatum is an effective threat and that sonication is necessary for the culturing of vegetations from plastic surfaces. Limitations of the current barcode marker ITS, and the long procedures required by a multistep approach, call for the development of rapid monophasic tests.

  16. Epicardial left ventricular lead placement for cardiac resynchronization therapy: optimal pace site selection with pressure-volume loops.

    Science.gov (United States)

    Dekker, A L A J; Phelps, B; Dijkman, B; van der Nagel, T; van der Veen, F H; Geskes, G G; Maessen, J G

    2004-06-01

    Patients in heart failure with left bundle branch block benefit from cardiac resynchronization therapy. Usually the left ventricular pacing lead is placed by coronary sinus catheterization; however, this procedure is not always successful, and patients may be referred for surgical epicardial lead placement. The objective of this study was to develop a method to guide epicardial lead placement in cardiac resynchronization therapy. Eleven patients in heart failure who were eligible for cardiac resynchronization therapy were referred for surgery because of failed coronary sinus left ventricular lead implantation. Minithoracotomy or thoracoscopy was performed, and a temporary epicardial electrode was used for biventricular pacing at various sites on the left ventricle. Pressure-volume loops with the conductance catheter were used to select the best site for each individual patient. Relative to the baseline situation, biventricular pacing with an optimal left ventricular lead position significantly increased stroke volume (+39%, P =.01), maximal left ventricular pressure derivative (+20%, P =.02), ejection fraction (+30%, P =.007), and stroke work (+66%, P =.006) and reduced end-systolic volume (-6%, P =.04). In contrast, biventricular pacing at a suboptimal site did not significantly change left ventricular function and even worsened it in some cases. To optimize cardiac resynchronization therapy with epicardial leads, mapping to determine the best pace site is a prerequisite. Pressure-volume loops offer real-time guidance for targeting epicardial lead placement during minimal invasive surgery.

  17. Results of remote follow-up and monitoring in young patients with cardiac implantable electronic devices.

    Science.gov (United States)

    Silvetti, Massimo S; Saputo, Fabio A; Palmieri, Rosalinda; Placidi, Silvia; Santucci, Lorenzo; Di Mambro, Corrado; Righi, Daniela; Drago, Fabrizio

    2016-01-01

    Remote monitoring is increasingly used in the follow-up of patients with cardiac implantable electronic devices. Data on paediatric populations are still lacking. The aim of our study was to follow-up young patients both in-hospital and remotely to enhance device surveillance. This is an observational registry collecting data on consecutive patients followed-up with the CareLink system. Inclusion criteria were a Medtronic device implanted and patient's willingness to receive CareLink. Patients were stratified according to age and presence of congenital/structural heart defects (CHD). A total of 221 patients with a device - 200 pacemakers, 19 implantable cardioverter defibrillators, and two loop recorders--were enrolled (median age of 17 years, range 1-40); 58% of patients were younger than 18 years of age and 73% had CHD. During a follow-up of 12 months (range 4-18), 1361 transmissions (8.9% unscheduled) were reviewed by technicians. Time for review was 6 ± 2 minutes (mean ± standard deviation). Missed transmissions were 10.1%. Events were documented in 45% of transmissions, with 2.7% yellow alerts and 0.6% red alerts sent by wireless devices. No significant differences were found in transmission results according to age or presence of CHD. Physicians reviewed 6.3% of transmissions, 29 patients were contacted by phone, and 12 patients underwent unscheduled in-hospital visits. The event recognition with remote monitoring occurred 76 days (range 16-150) earlier than the next scheduled in-office follow-up. Remote follow-up/monitoring with the CareLink system is useful to enhance device surveillance in young patients. The majority of events were not clinically relevant, and the remaining led to timely management of problems.

  18. Electrical storm presages nonsudden death: the antiarrhythmics versus implantable defibrillators (AVID) trial.

    Science.gov (United States)

    Exner, D V; Pinski, S L; Wyse, D G; Renfroe, E G; Follmann, D; Gold, M; Beckman, K J; Coromilas, J; Lancaster, S; Hallstrom, A P

    2001-04-24

    Electrical storm, multiple temporally related episodes of ventricular tachycardia (VT) or ventricular fibrillation (VF), is a frequent problem among recipients of implantable cardioverter defibrillators (ICDs). However, insufficient data exist regarding its prognostic significance. This analysis includes 457 patients who received an ICD in the Antiarrhythmics Versus Implantable Defibrillators (AVID) trial and who were followed for 31 +/- 13 months. Electrical storm was defined as > or = 3 separate episodes of VT/VF within 24 hours. Characteristics and survival of patients surviving electrical storm (n = 90), those with VT/VF unrelated to electrical storm (n = 184), and the remaining patients (n = 183) were compared. The 3 groups differed in terms of ejection fraction, index arrhythmia, revascularization status, and baseline medication use. Survival was evaluated using time-dependent Cox modeling. Electrical storm occurred 9.2 +/- 11.5 months after ICD implantation, and most episodes (86%) were due to VT. Electrical storm was a significant risk factor for subsequent death, independent of ejection fraction and other prognostic variables (relative risk [RR], 2.4; 95% confidence interval [CI], 1.3 to 4.2; P = 0.003), but VT/VF unrelated to electrical storm was not (RR, 1.0; 95% CI, 0.6 to 1.7; P = 0.9). The risk of death was greatest 3 months after electrical storm (RR, 5.4; 95% Cl, 2.4 to 12.3; P = 0.0001) and diminished beyond this time (RR, 1.9; 95% CI, 1.0 to 3.6; P=0.04). Electrical storm is an important, independent marker for subsequent death among ICD recipients, particularly in the first 3 months after its occurrence. However, the development of VT/VF unrelated to electrical storm does not seem to be associated with an increased risk of subsequent death.

  19. Physicians’ knowledge and attitudes in Saudi Arabia regarding implantable cardiac defibrillators

    Directory of Open Access Journals (Sweden)

    Tariq Alhogbani

    2018-04-01

    Full Text Available Objectives: To evaluate knowledge and attitude of physicians involved in the management of patients with heart failure regarding implantable cardioverter-defibrillator (ICD. Methods: We conducted personal interviews with physicians involved in treating patients with heart failure. Between October 2015 and February 2016, the study was conducted in hospitals in the Riyadh region where no cardiac electrophysiology service was available. Every participant was met in person and received an oral questionnaire that aimed to assess basic knowledge regarding ICD indications and benefits. Results: Sixty-three physicians were met from 13 hospitals (14 consultants and 49 specialists. Forty-one percent of participants use the recommended cut-off level of left ventricular ejection fraction (LVEF which is ≤35% as the LVEF criterion for ICD referral in patients with cardiomyopathy. Only 50% of the consultants use ≤35% as the LVEF criterion for ICD referral. Seventy percent of the participants thought that ICD may improve heart failure symptoms. Forty-eight percent of physicians have a defined channel to refer patients to higher centers for ICD implant. There was no statistically significant difference between physicians’ knowledge when we categorized them according to three different factors: (1 physician’s specialty (cardiology vs. internal medicine; (2 physician’s degree (consultant vs. specialist; and (3 physician’s location (inside vs. outside Riyadh city. Conclusion: There is a lack of knowledge of current clinical guidelines regarding ICD implantation for patients with heart failure at general hospitals in Saudi Arabia. This finding highlights the need to improve the dissemination of guidelines to practitioners involved in managing patients with heart failure in an effort to improve ICD utilization. Keywords: Cardiac defibrillator, Heart failure, Physicians’ knowledge, Saudi Arabia

  20. Defibrillator implantations for primary prevention in the United States: Inappropriate care or inadequate documentation: Insights from the National Cardiovascular Data ICD Registry.

    Science.gov (United States)

    Kaiser, Daniel W; Tsai, Vivian; Heidenreich, Paul A; Goldstein, Mary K; Wang, Yongfei; Curtis, Jeptha; Turakhia, Mintu P

    2015-10-01

    Prior studies have reported that more than 20% of implantable cardioverter-defibrillator (ICD) implantations in the United States do not adhere to trial-based criteria. We sought to investigate the patient characteristics associated with not meeting the inclusion criteria of the clinical trials that have demonstrated the efficacy of primary prevention ICDs. Using data from the National Cardiovascular Data Registry's ICD Registry, we identified patients who received ICDs for primary prevention from January 2006 to December 2008. We determined whether patients met the inclusion criteria of at least 1 of the 4 ICD primary prevention trials: Multicenter Automatic Defibrillator Implantation Trial (MADIT), MADIT-II, Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), and the Multicenter Unsustained Tachycardia Trial (MUSTT). Among 150,264 patients, 86% met criteria for an ICD implantation based on trial data. The proportion of patients who did not meet trial-based criteria increased as age decreased. In multivariate analysis, the significant predictors for not meeting trial criteria included prior cardiac transplantation (odds ratio [OR] 2.1), pediatric electrophysiology operator (OR 2.0), and high-grade atrioventricular conduction disease (OR 1.4). Among National Cardiovascular Data Registry registrants receiving first-time ICDs for primary prevention, the majority met trial-based criteria. Multivariate analyses suggested that many patients who did not meet the trial-based criteria may have had clinical circumstances that warranted ICD implantation. These findings caution against the use of trial-based indications to determine site quality metrics that could penalize sites that care for younger patients. The planned incorporation of appropriate use criteria into the ICD registry may better characterize patient- and site-level quality and performance. Published by Elsevier Inc.

  1. [National Consultant in Cardiology Experts' Group Guidelines on dealing with patients implanted with some St. Jude Medical Riata and Riata ST leads].

    Science.gov (United States)

    Mitkowski, Przemysław; Grabowski, Marcin; Kowalski, Oskar; Kutarski, Andrzej; Mojkowski, Włodzimierz; Przybylski, Andrzej; Sterliński, Maciej; Trusz-Gluza, Maria; Opolski, Grzegorz

    2014-01-01

    In December 2010 St. Jude Medical informed about higher incidence of silicone insulation abrasion in implantable cardioverter-defibrillator leads Riata/Riata ST. The manifestation of this phenomenon is the externalisation of conductors outside the body of the lead, which is visible in a fluoroscopy. The abrasion could also involve an insulation under high-voltage coil and in the worst case could result in a short circuit within high voltage part of the system. The incidence of this phenomenon varies from part of to several dozen percent according to published papers and becomes higher in a longer follow-up. The highest probability of malfunction in 8 F single coil and the lowest in 7 F dual-coil leads is observed. For the needs of this guidelines all Riata/Riata ST leads were divided into: functioning, damaged but active (visible externalisation but electrically functioning), malfunctioning. In the last case the lead should be removed and a new one implanted (class of indication I) ,although only implantation of a new lead with abandoning malfunctioning one is allowed and should be considered (IIa). In patients with functioning lead extraction with a new lead implantation may be considered during elective replacement only in high risk patients (IIb). In case of damaged but active lead its extraction with the implantation of a new lead during elective replacement of the device should be considered in high risk population (IIa) and may be considered in other patients (IIb). The final decision related to Riata/Riata ST should be individualised and undertaken in co-operation with the patient after detailed assessment of the risk related to each treatment option.

  2. Fully digital data processing during cardiovascular implantable electronic device follow-up in a high-volume tertiary center.

    Science.gov (United States)

    Staudacher, Ingo; Nalpathamkalam, Asha Roy; Uhlmann, Lorenz; Illg, Claudius; Seehausen, Sebastian; Akhavanpoor, Mohammadreza; Buchauer, Anke; Geis, Nicolas; Lugenbiel, Patrick; Schweizer, Patrick A; Xynogalos, Panagiotis; Zylla, Maura M; Scholz, Eberhard; Zitron, Edgar; Katus, Hugo A; Thomas, Dierk

    2017-10-11

    Increasing numbers of patients with cardiovascular implantable electronic devices (CIEDs) and limited follow-up capacities highlight unmet challenges in clinical electrophysiology. Integrated software (MediConnect ® ) enabling fully digital processing of device interrogation data has been commercially developed to facilitate follow-up visits. We sought to assess feasibility of fully digital data processing (FDDP) during ambulatory device follow-up in a high-volume tertiary hospital to provide guidance for future users of FDDP software. A total of 391 patients (mean age, 70 years) presenting to the outpatient department for routine device follow-up were analyzed (pacemaker, 44%; implantable cardioverter defibrillator, 39%; cardiac resynchronization therapy device, 16%). Quality of data transfer and follow-up duration were compared between digital (n = 265) and manual processing of device data (n = 126). Digital data import was successful, complete and correct in 82% of cases when early software versions were used. When using the most recent software version the rate of successful digital data import increased to 100%. Software-based import of interrogation data was complete and without failure in 97% of cases. The mean duration of a follow-up visit did not differ between the two groups (digital 18.7 min vs. manual data transfer 18.2 min). FDDP software was successfully implemented into the ambulatory follow-up of patients with implanted pacemakers and defibrillators. Digital data import into electronic patient management software was feasible and supported the physician's workflow. The total duration of follow-up visits comprising technical device interrogation and clinical actions was not affected in the present tertiary center outpatient cohort.

  3. ECG-derived spatial QRS-T angle is associated with ICD implantation, mortality and heart failure admissions in patients with LV systolic dysfunction.

    Directory of Open Access Journals (Sweden)

    Sarah Gleeson

    Full Text Available Increased spatial QRS-T angle has been shown to predict appropriate implantable cardioverter defibrilIator (ICD therapy in patients with left ventricular systolic dysfunction (LVSD. We performed a retrospective cohort study in patients with left ventricular ejection fraction (LVEF 31-40% to assess the relationship between the spatial QRS-T angle and other advanced ECG (A-ECG as well as echocardiographic metadata, with all-cause mortality or ICD implantation for secondary prevention.534 patients ≤75 years of age with LVEF 31-40% were identified through an echocardiography reporting database. Digital 12-lead ECGs were retrospectively matched to 295 of these patients, for whom echocardiographic and A-ECG metadata were then generated. Data mining was applied to discover novel ECG and echocardiographic markers of risk. Machine learning was used to develop a model to predict possible outcomes.49 patients (17% had events, defined as either mortality (n = 16 or ICD implantation for secondary prevention (n = 33. 72 parameters (58 A-ECG, 14 echocardiographic were univariately different (p110° had an adjusted HR of 3.4 (95% CI 1.6 to 7.4 for secondary ICD implantation or all-cause death and adjusted HR of 4.1 (95% CI 1.2 to 13.9 for future heart failure admission. There was a loss of complexity between A-ECG and echocardiographic variables with an increasing degree of disease.Spatial QRS-T angle >110° was strongly associated with arrhythmic events and all-cause death. Deep analysis of global ECG and echocardiographic metadata revealed underlying relationships, which otherwise would not have been appreciated. Delivered at scale such techniques may prove useful in clinical decision making in the future.

  4. Estudo clínico de um sistema cardioversor-desfibrilador implantável que apresenta limiares de desfibrilação baixos usando eletrodos de estrutura fractal Clinical studies of an implantable cardioversor - defibrillators system providing low defibrillation thresholds as well as high signal amplitudes due to fractal coated electrodes

    Directory of Open Access Journals (Sweden)

    Fernando A. LUCCHESE

    1999-01-01

    Full Text Available Em função do contínuo desenvolvimento tecnológico, a geração atual de cardioversores-desfibriladores implantáveis (CDI garante um alto grau de segurança e eficiência na detecção e reversão de taquiarritmias ventriculares. O presente trabalho sumariza os resultados clínicos obtidos com 1058 CDI de câmara única (Phylax 6, Phylax XM, Biotronik utilizando eletrodo único e tecnologia de carcaça ativa, SPS e Kainox RV (com uma mola intracavitária de choque, SL-ICD e Kainox SL (com duas molas intracavitárias de choque, Biotronik. Na quase totalidade dos pacientes, com exceção de 3 (> 99%, foram obtidos limiares de desfibrilação com baixa energia usando apenas um eletrodo transvenoso. Isto tem permitido substituir o teste de limiar de desfibrilação usual por um teste simples durante o implante, afim de minimizar os riscos associados com repetidas induções de fibrilação e conseqüente extensão do período de anestesia.Due to continuously improved technologies, the present generation of implantable cardioverter-defibrillators (ICD guarantees a high degree of safety and efficacy for detecting and terminating ventricular tachyarrhythmias. This paper summarizes the clinical results obtained with 1058 single-chamber ICD (Phylax 6, Phylax XM, Biotronik employing single-lead and active housing technology (SPS and Kainox RV (single coil, SL-ICD and Kainox SL (double coil, Biotronik. In all but 3 patients (> 99%, reliable low-energy defibrillation was achieved using transvenous leads only. This has led to the trend to replace DFT testing by a short function test during implantation in order to minimize the risks associated with repeated induction of fibrillation and extended anesthesia.

  5. Safety and interaction of patients with implantable cardiac defibrillators driving a hybrid vehicle.

    Science.gov (United States)

    Tondato, Fernando; Bazzell, Jane; Schwartz, Linda; Mc Donald, Bruce W; Fisher, Robert; Anderson, S Shawn; Galindo, Arcenio; Dueck, Amylou C; Scott, Luis R

    2017-01-15

    Electromagnetic interference (EMI) can affect the function of implantable cardioverter defibrillators (ICD). Hybrid electric vehicles (HEV) have increased popularity and are a potential source of EMI. Little is known about the in vivo effects of EMI generated by HEV on ICD. This study evaluated the in vivo interaction between EMI generated by HEV with ICD. Thirty patients (73±9 y/o; 80% male) with stable ICD function were exposed to EMI generated by a Toyota Prius Hybrid®. The vehicle was lifted above the ground, allowing safe changes in engine rotation and consequent variations in electromagnetic emission. EMI was measured (NARDA STS® model EHP-50C) and expressed in A/m (magnetic), Volts/m (electrical), and Hertz (frequency). Six positions were evaluated: driver, front passenger, right and left back seats, outside, at the back and front of the car. Each position was evaluated at idle, 30 mph, 60 mph and variable speeds (acceleration-deceleration-brake). All ICD devices were continuously monitored during the study. The levels of EMI generated were low (highest mean levels: 2.09A/m at right back seat at 30 mph; and 3.5V/m at driver seat at variable speeds). No episode of oversensing or inadvertent change in ICD programming was observed. It is safe for patients with ICD to interact with HEV. This is the first study to address this issue using an in vivo model. Further studies are necessary to evaluate the interaction of different models of HEV or electric engine with ICD or unipolar pacemakers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Radiotherapy-Induced Cardiac Implantable Electronic Device Dysfunction in Patients With Cancer.

    Science.gov (United States)

    Bagur, Rodrigo; Chamula, Mathilde; Brouillard, Émilie; Lavoie, Caroline; Nombela-Franco, Luis; Julien, Anne-Sophie; Archambault, Louis; Varfalvy, Nicolas; Gaudreault, Valérie; Joncas, Sébastien X; Israeli, Zeev; Parviz, Yasir; Mamas, Mamas A; Lavi, Shahar

    2017-01-15

    Radiotherapy can affect the electronic components of a cardiac implantable electronic device (CIED) resulting in malfunction and/or damage. We sought to assess the incidence, predictors, and clinical impact of CIED dysfunction (CIED-D) after radiotherapy for cancer treatment. Clinical characteristics, cancer, different types of CIEDs, and radiation dose were evaluated. The investigation identified 230 patients, mean age 78 ± 8 years and 70% were men. A total of 199 patients had pacemakers (59% dual chamber), 21 (9%) cardioverter-defibrillators, and 10 (4%) resynchronizators or defibrillators. The left pectoral (n = 192, 83%) was the most common CIED location. Sixteen patients (7%) experienced 18 events of CIED-D after radiotherapy. Reset to backup pacing mode was the most common encountered dysfunction, and only 1 (6%) patient of those with CIED-D experienced symptoms of atrioventricular dyssynchrony. Those who had CIED-D tended to have a shorter device age at the time of radiotherapy compared to those who did not (2.5 ± 1.5 vs 3.8 ± 3.4 years, p = 0.09). The total dose prescribed to the tumor was significantly greater among those who had CIED-D (66 ± 30 vs 42 ± 23 Gy, p radiotherapy for cancer treatment, the occurrence of newly diagnosed CIED-D was 7%, and the reset to backup pacing mode was the most common encountered dysfunction. The total dose prescribed to the tumor was a predictor of CIED-D. Importantly, although the unpredictability of CIEDs under radiotherapy is still an issue, none of our patients experienced significant symptoms, life-threatening arrhythmias, or conduction disorders. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. SU-F-T-452: Influence of Dose Calculation Algorithm and Heterogeneity Correction On Risk Categorization of Patients with Cardiac Implanted Electronic Devices Undergoing Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Iwai, P; Lins, L Nadler [AC Camargo Cancer Center, Sao Paulo (Brazil)

    2016-06-15

    Purpose: There is a lack of studies with significant cohort data about patients using pacemaker (PM), implanted cardioverter defibrillator (ICD) or cardiac resynchronization therapy (CRT) device undergoing radiotherapy. There is no literature comparing the cumulative doses delivered to those cardiac implanted electronic devices (CIED) calculated by different algorithms neither studies comparing doses with heterogeneity correction or not. The aim of this study was to evaluate the influence of the algorithms Pencil Beam Convolution (PBC), Analytical Anisotropic Algorithm (AAA) and Acuros XB (AXB) as well as heterogeneity correction on risk categorization of patients. Methods: A retrospective analysis of 19 3DCRT or IMRT plans of 17 patients was conducted, calculating the dose delivered to CIED using three different calculation algorithms. Doses were evaluated with and without heterogeneity correction for comparison. Risk categorization of the patients was based on their CIED dependency and cumulative dose in the devices. Results: Total estimated doses at CIED calculated by AAA or AXB were higher than those calculated by PBC in 56% of the cases. In average, the doses at CIED calculated by AAA and AXB were higher than those calculated by PBC (29% and 4% higher, respectively). The maximum difference of doses calculated by each algorithm was about 1 Gy, either using heterogeneity correction or not. Values of maximum dose calculated with heterogeneity correction showed that dose at CIED was at least equal or higher in 84% of the cases with PBC, 77% with AAA and 67% with AXB than dose obtained with no heterogeneity correction. Conclusion: The dose calculation algorithm and heterogeneity correction did not change the risk categorization. Since higher estimated doses delivered to CIED do not compromise treatment precautions to be taken, it’s recommend that the most sophisticated algorithm available should be used to predict dose at the CIED using heterogeneity correction.

  8. A protocol for patients with cardiovascular implantable devices undergoing magnetic resonance imaging (MRI): should defibrillation threshold testing be performed post-(MRI).

    Science.gov (United States)

    Burke, Peter Thomas; Ghanbari, Hamid; Alexander, Patrick B; Shaw, Michael K; Daccarett, Marcos; Machado, Christian

    2010-06-01

    Magnetic resonance imaging (MRI) in patients with Cardiovascular Implantable Electronic Devices (CIED) has not been approved by the Food and Drug Administration. Recent data suggests MRI as a relative rather than absolute contraindication in CIED patients. Recently, the American Heart Association has recommended defibrillation threshold testing (DFTT) in implantable cardioverter defibrillator (ICD) patients undergoing MRI. We evaluated the feasibility and safety of a protocol for MRI in CIED patients, incorporating the new recommendations on DFTT. Consecutive patients with CIED undergoing MRI were included. The protocol consisted of continuous monitoring during imaging, device interrogation pre- and post-MRI, reprogramming of the pacemaker to an asynchronous mode in pacemaker-dependent (PMD) patients and a non-tracking/sensing mode for non-PMD patients. All tachyarrhythmia therapies were disabled. Devices were interrogated for lead impedance, battery life, pacing, and sensing thresholds. All patients with ICD underwent DFTT/defibrillator safety margin testing (DSMT) post-MRI. A total of 92 MRI's at 1.5 Tesla were performed in 38 patients. A total of 13 PMD patients, ten ICD patients, four cardiac resynchronization therapy with defibrillator (CRT-D) patients, and 11 non-PMD patients were scanned from four major manufacturers. No device circuitry damage, programming alterations, inappropriate shocks, failure to pace, or changes in sensing, pacing, or defibrillator thresholds were found on single or multiple MRI sessions. Our protocol for MRI in CIED patients appears safe, feasible, and reproducible. This is irrespective of the type of CIED, pacemaker dependancy or multiple 24-h scanning sessions. Our protocol addresses early detection of potential complications and establishes a response system for potential device-related complications. Our observation suggests that routine DFTT/DSMT post-MRI may not be necessary.

  9. SU-F-T-452: Influence of Dose Calculation Algorithm and Heterogeneity Correction On Risk Categorization of Patients with Cardiac Implanted Electronic Devices Undergoing Radiotherapy

    International Nuclear Information System (INIS)

    Iwai, P; Lins, L Nadler

    2016-01-01

    Purpose: There is a lack of studies with significant cohort data about patients using pacemaker (PM), implanted cardioverter defibrillator (ICD) or cardiac resynchronization therapy (CRT) device undergoing radiotherapy. There is no literature comparing the cumulative doses delivered to those cardiac implanted electronic devices (CIED) calculated by different algorithms neither studies comparing doses with heterogeneity correction or not. The aim of this study was to evaluate the influence of the algorithms Pencil Beam Convolution (PBC), Analytical Anisotropic Algorithm (AAA) and Acuros XB (AXB) as well as heterogeneity correction on risk categorization of patients. Methods: A retrospective analysis of 19 3DCRT or IMRT plans of 17 patients was conducted, calculating the dose delivered to CIED using three different calculation algorithms. Doses were evaluated with and without heterogeneity correction for comparison. Risk categorization of the patients was based on their CIED dependency and cumulative dose in the devices. Results: Total estimated doses at CIED calculated by AAA or AXB were higher than those calculated by PBC in 56% of the cases. In average, the doses at CIED calculated by AAA and AXB were higher than those calculated by PBC (29% and 4% higher, respectively). The maximum difference of doses calculated by each algorithm was about 1 Gy, either using heterogeneity correction or not. Values of maximum dose calculated with heterogeneity correction showed that dose at CIED was at least equal or higher in 84% of the cases with PBC, 77% with AAA and 67% with AXB than dose obtained with no heterogeneity correction. Conclusion: The dose calculation algorithm and heterogeneity correction did not change the risk categorization. Since higher estimated doses delivered to CIED do not compromise treatment precautions to be taken, it’s recommend that the most sophisticated algorithm available should be used to predict dose at the CIED using heterogeneity correction.

  10. The impact of changing antiseptic skin preparation agent used for cardiac implantable electronic device (CIED) procedures on the risk of infection.

    Science.gov (United States)

    Qintar, Mohammed; Zardkoohi, Omeed; Hammadah, Muhammad; Hsu, Amy; Wazni, Oussama; Wilkoff, Bruce L; Tarakji, Khaldoun G

    2015-02-01

    Cardiac implantable electronic device (CIED) infection is a major complication that is associated with increased morbidity and mortality. Recent data suggested a relationship between the antiseptic agent used for skin preparation at time of CIED procedure and risk for infection. On April 30, 2011, we changed the antiseptic agent used for skin preparation at our tertiary care facility from chlorhexidine-alcohol to povidone-iodine for all CIED procedures. We retrospectively reviewed records of all patients who underwent CIED procedure 1 year before and after the change. CIED infection was defined as pocket or endovascular systemic infection that required removal within 1 year of the index procedure. We examined if the change affected the risk of CIED infection. A total of 2,792 patients underwent 2,840 CIED procedures; 1,748 (61.5%) had implantable cardioverter defibrillator procedures and 1,092 (38.4%) had permanent pacemaker procedures. Chlorhexidine-alcohol agent was used in 1,450 (51.1%) procedures, and povidone-iodine agent was used in 1,390 (48.9%). After 1 year of follow-up, 31 patients (1.09%) developed CIED infection that required system removal. The 1-year infection rate was 1.1% among both antiseptic agent groups and there were no significant differences in the infection presentations among both groups (P = 0.950). Multivariate Cox proportional hazards regression model showed that risk factors for infection within 1 year included age, diabetes, and African American race. In one large cohort of patients undergoing CIED procedures, the antiseptic agent used for skin preparation (chlorhexidine-alcohol vs povidone-iodine) was not associated with increased risk of developing CIED infection. ©2014 Wiley Periodicals, Inc.

  11. Risk factors and prognostic role of an electrical storm in patients after myocardial infarction with an implanted ICD for secondary prevention.

    Science.gov (United States)

    Kwaśniewski, Wojciech; Filipecki, Artur; Orszulak, Michał; Orszulak, Witold; Urbańczyk, Dagmara; Roczniok, Robert; Trusz-Gluza, Maria; Mizia-Stec, Katarzyna

    2018-04-01

    The aim of our study was to determine the risk factors for electrical storm (ES) and to assess the impact of ES on the long-term prognosis in patients after myocardial infarction (MI) with an implantable cardioverter-defibrillator (ICD) for secondary prevention of sudden cardiac death (SCD). We retrospectively analyzed 416 patients with coronary artery disease after MI who had an implanted ICD for secondary prevention of SCD. Fifty (12%) patients had one or more incidents of an electrical storm - the ES (+) group. We matched the reference group of 47 patients from 366 ES (-) patients. We analyzed 3,408 episodes of ventricular arrhythmias: 3,148 ventricular tachyarrhythmic episodes in the ES (+) group (including 187 episodes of ES) and 260 in the ES (-) group. Multivariate logistic regression showed that inferior wall MI (RR = 3.98, 95% CI: 1.52-10.41) and the absence of coronary revascularization (RR = 2.92, 95% CI: 1.18-7.21) were independent predictors of ES ( p = 0.0014). During 6-year observation of 97 patients, there were 39 (40%) deaths: 25 (50%) subjects in the ES (+) group and 14 (30%) in the ES (-) group ( p = 0.036). Independent predictors of death were: the occurrence of ES (HR = 1.93), older age (HR = 1.06), and lower left ventricular ejection fraction (HR = 0.95) (for all p storm in patients after MI with ICD for secondary prevention is a relatively common phenomenon and has a negative prognostic significance. Myocardial infarction of the inferior wall and the absence of coronary revascularization are predisposing factors for the occurrence of an ES.

  12. Remote monitoring improves outcome after ICD implantation: the clinical efficacy in the management of heart failure (EFFECT) study.

    Science.gov (United States)

    De Simone, Antonio; Leoni, Loira; Luzi, Mario; Amellone, Claudia; Stabile, Giuseppe; La Rocca, Vincenzo; Capucci, Alessandro; D'onofrio, Antonio; Ammendola, Ernesto; Accardi, Francesco; Valsecchi, Sergio; Buja, Gianfranco

    2015-08-01

    Internet-based remote interrogation systems have been shown to reduce emergency department and in-office visits in patients with implantable cardioverter defibrillators (ICDs), resulting in increased efficiency for healthcare providers. Nonetheless, studies sized to demonstrate the impact of remote monitoring on patients' outcome have been lacking. The EFFECT study was a multicentre clinical trial aimed at measuring and comparing the outcome of ICD patients conventionally followed-up by means of in-clinic visits (Standard arm) or by remote monitoring (Remote arm) in the clinical practice of 25 Italian centres. From 2011 to 2013, 987 consecutive patients were enrolled and followed up for at least 12 months. The primary endpoint was the rate of death and cardiovascular hospitalizations. Remote monitoring was adopted by 499 patients. Patients in the Standard and Remote arms did not differ significantly in terms of baseline clinical characteristics, except for a more frequent use of ICD with cardiac resynchronization therapy (CRT-D) in the Remote arm (48 vs. 36%, P Remote arm (incident rate ratio, 0.55; 95% CI, 0.41-0.73; P Remote arms were 0.27 and 0.08 events/year, respectively, among CRT-D recipients (P Remote arm. Compared with the standard follow-up through in-office visits, remote monitoring is associated with reduced death and cardiovascular hospitalizations in patients with ICD in clinical practice. URL: http://clinicaltrials.gov/ Identifier: NCT01723865. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  13. Revealing new mouse epicardial cell markers through transcriptomics.

    Directory of Open Access Journals (Sweden)

    Lars Bochmann

    2010-06-01

    Full Text Available The epicardium has key functions during myocardial development, by contributing to the formation of coronary endothelial and smooth muscle cells, cardiac fibroblasts, and potentially cardiomyocytes. The epicardium plays a morphogenetic role by emitting signals to promote and maintain cardiomyocyte proliferation. In a regenerative context, the adult epicardium might comprise a progenitor cell population that can be induced to contribute to cardiac repair. Although some genes involved in epicardial function have been identified, a detailed molecular profile of epicardial gene expression has not been available.Using laser capture microscopy, we isolated the epicardial layer from the adult murine heart before or after cardiac infarction in wildtype mice and mice expressing a transgenic IGF-1 propeptide (mIGF-1 that enhances cardiac repair, and analyzed the transcription profile using DNA microarrays.Expression of epithelial genes such as basonuclin, dermokine, and glycoprotein M6A are highly enriched in the epicardial layer, which maintains expression of selected embryonic genes involved in epicardial development in mIGF-1 transgenic hearts. After myocardial infarct, a subset of differentially expressed genes are down-regulated in the epicardium representing an epicardium-specific signature that responds to injury.This study presents the description of the murine epicardial transcriptome obtained from snap frozen tissues, providing essential information for further analysis of this important cardiac cell layer.

  14. Comparison of arrhythmogenicity and proinflammatory activity induced by intramyocardial or epicardial myoblast sheet delivery in a rat model of ischemic heart failure.

    Directory of Open Access Journals (Sweden)

    Tommi Pätilä

    Full Text Available Although cell therapy of the failing heart by intramyocardial injections of myoblasts to results in regenerative benefit, it has also been associated with undesired and prospectively fatal arrhythmias. We hypothesized that intramyocardial injections of myoblasts could enhance inflammatory reactivity and facilitate electrical cardiac abnormalities that can be reduced by epicardial myoblast sheet delivery. In a rat model of ischemic heart failure, myoblast therapy either by intramyocardial injections or epicardial cell sheets was given 2 weeks after occlusion of the coronary artery. Ventricular premature contractions (VPCs were assessed, using an implanted three-lead electrocardiograph at 1, 7, and 14 days after therapy, and 16-point epicardial electropotential mapping (EEPM was used to evaluate ventricular arrhythmogenicity under isoproterenol stress. Cardiac functioning was assessed by echocardiography. Both transplantation groups showed therapeutic benefit over sham therapy. However, VPCs were more frequent in the Injection group on day 1 and day 14 after therapy than in animals receiving epicardial or sham therapy (p < 0.05 and p < 0.01, respectively. EEPM under isoproterenol stress showed macroreentry at the infarct border area, leading to ventricular tachycardias in the Injection group, but not in the myoblast sheet- or sham-treated groups (p = 0.045. Both transplantation types modified the myocardial cytokine expression profile. In animals receiving epicardial myoblast therapy, selective reductions in the expressions of interferon gamma, interleukin (IL-1β and IL12 were observed, accompanied by reduced infiltration of inflammatory CD11b- and CD68-positive leukocytes, compared with animals receiving myoblasts as intramyocardial injections. Intramyocardial myoblast delivery was associated with enhanced inflammatory and immunomodulatory reactivity and increased frequency of VPCs. In comparison to intramyocardial injection, the epicardial

  15. Emotions and health

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Stoier, Louise; Moons, Philip

    2015-01-01

    Serious illness will inevitably lead to a fundamental emotional reaction. Traditionally, in interventional treatment or rehabilitation trials, the psychological status of patients with implantable cardioverter defibrillators has been evaluated with anxiety and depression as outcome measures. In c....... In caring for these patients, the aim of nursing is to help patients manage life with complex heart disease. The early detection and management of negative emotional response might prevent the development of pathological conditions such as depression.......Serious illness will inevitably lead to a fundamental emotional reaction. Traditionally, in interventional treatment or rehabilitation trials, the psychological status of patients with implantable cardioverter defibrillators has been evaluated with anxiety and depression as outcome measures...

  16. Study Design and Cohort Description of DEFIB-WOMEN

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Nielsen, Jens Cosedis; Riahi, Sam

    2016-01-01

    BACKGROUND: Little systematic evidence is available on potential gender differences in patients with an implantable cardioverter defibrillator (ICD) from a real-world cohort. We designed the DEFIB-WOMEN (The Utilization of Implantable Cardioverter DEFIBrillator Therapy in the Treatment of Heart......-converting enzyme inhibitors, and psychotropic agents. Although women generally had a healthier clinical profile, they reported significantly more symptoms of anxiety and depression and ICD concerns (fear of shock) as compared to men. These differences were not only statistically significant but also clinically...

  17. Association between hospital procedure volume and early complications after pacemaker implantation: results from a large, unselected, contemporary cohort of the German nationwide obligatory external quality assurance programme.

    Science.gov (United States)

    Nowak, Bernd; Tasche, Karl; Barnewold, Linda; Heller, Günther; Schmidt, Boris; Bordignon, Stefano; Chun, K R Julian; Fürnkranz, Alexander; Mehta, Rajendra H

    2015-05-01

    Several studies demonstrated an inverse relationship between cardioverter-defibrillator implantation volume and complication rates, suggesting better outcomes for higher volume centres. However, the association of institutional procedural volume with patient outcomes for permanent pacemaker (PPM) implantation remains less known, especially in decentralized implantation systems. We performed retrospective examination of data on patients undergoing PPM from the German obligatory quality assurance programme (2007-12) to evaluate the relationship of hospital PPM volume (categorized into quintiles of their mean annual volume) with risk-adjusted in-hospital surgical complications (composite of pneumothorax, haemothorax, pericardial effusion, or pocket haematoma, all requiring intervention, or device infection) and pacemaker lead dislocation. Overall 430 416 PPM implantations were documented in 1226 hospitals. Systems included dual (72.8%) and single (25.8%) chamber PPM and cardiac resynchronization therapy (CRT) devices (1.1%). Complications included surgical (0.92%), and ventricular (0.99%), and atrial (1.22%) lead dislocation. Despite an increase in relatively complex procedures (dual chamber, CRT), there was a significant decrease in the procedural and fluoroscopy times and complications from lowest to highest implantation volume quintiles (P for trend <0.0001). The greatest difference was observed between the lowest (1-50 implantations/year-reference group) and the second-lowest (51-90 implantations/year) quintile: surgical complications [odds ratio (OR) 0.69; confidence interval (CI) 0.60-0.78], atrial lead dislocations (OR 0.69; CI 0.59-0.80), and ventricular lead dislocations (OR 0.73; CI 0.63-0.84). Hospital annual PPM volume was directly related to indication-based implantation of relatively more complex PPM and yet inversely with procedural times and rates of early surgical complications and lead dislocations. Thus, our data suggest better performance and lower

  18. Prevention of Cardiac Implantable Electronic Device Infections: Single Operator Technique with Use of Povidone-Iodine, Double Gloving, Meticulous Aseptic/Antiseptic Measures and Antibiotic Prophylaxis.

    Science.gov (United States)

    Manolis, Antonis S; Melita, Helen

    2017-01-01

    Cardiac implantable electronic device (CIED) implantation is complicated by infection still at a worrisome rate of 2-5%. Since early on during device implantation procedures, we have adopted an infection-preventive technique which has hitherto resulted in effective prevention of infections. Herein we present our results of applying this technique by a single operator in a prospective series of 762 consecutive patients undergoing device implantation. A meticulous search for and treatment of active, occult, or smoldering infection was undertaken preoperatively. An aseptic/antiseptic technique was used for implantation of each device. Skin preparation is thorough with initial cleansing performed with alcohol followed by povidone-iodine 10% solution, which is also used in the wound and inside the pocket. In addition, we routinely use double gloving, and IV antibiotic prophylaxis 1 hour before and for 48 hours afterwards followed by oral antibiotic for 2-3 days after discharge. The skin is closed with absorbable sutures. The study includes 382 patients having a new pacemaker (n = 333) or battery change, system upgrade or lead revision (n = 49), and 380 patients having a new implantable cardioverter-defibrillator (ICD) (n = 296) or device replacement/upgrade/lead revision (n = 84). The pacemaker group, aged 70.2 ± 16.5 years, includes 18% VVI, 49% DDD, 29% VDD, and 4% cardiac resynchronization therapy (CRT) devices. The ICD group, aged 61.3 ± 13.0 years, with a mean ejection fraction of 36 ± 13%, includes 325 ICD and 55 CRT implants. Over 26.6 ± 33.4 months for the pacemaker group and 36.6 ± 38.3 months for the ICD group, infection occurred in one patient in each group (0.26%) having a device replacement. A consistent and strict approach of aseptic/antiseptic technique with the use of double gloving and povidone-iodine solution within the pocket plus a 4-day regimen of antibiotic prophylaxis minimizes infections in CIED implants. © 2016 Wiley Periodicals, Inc.

  19. Malfunctions of Implantable Cardiac Devices in Patients Receiving Proton Beam Therapy: Incidence and Predictors

    International Nuclear Information System (INIS)

    Gomez, Daniel R.; Poenisch, Falk; Pinnix, Chelsea C.; Sheu, Tommy; Chang, Joe Y.; Memon, Nada; Mohan, Radhe; Rozner, Marc A.; Dougherty, Anne H.

    2013-01-01

    Purpose: Photon therapy has been reported to induce resets of implanted cardiac devices, but the clinical sequelae of treating patients with such devices with proton beam therapy (PBT) are not well known. We reviewed the incidence of device malfunctions among patients undergoing PBT. Methods and Materials: From March 2009 through July 2012, 42 patients with implanted cardiac implantable electronic devices (CIED; 28 pacemakers and 14 cardioverter-defibrillators) underwent 42 courses of PBT for thoracic (23, 55%), prostate (15, 36%), liver (3, 7%), or base of skull (1, 2%) tumors at a single institution. The median prescribed dose was 74 Gy (relative biological effectiveness; range 46.8-87.5 Gy), and the median distance from the treatment field to the CIED was 10 cm (range 0.8-40 cm). Maximum proton and neutron doses were estimated for each treatment course. All CIEDs were checked before radiation delivery and monitored throughout treatment. Results: Median estimated peak proton and neutron doses to the CIED in all patients were 0.8 Gy (range 0.13-21 Gy) and 346 Sv (range 11-1100 mSv). Six CIED malfunctions occurred in 5 patients (2 pacemakers and 3 defibrillators). Five of these malfunctions were CIED resets, and 1 patient with a defibrillator (in a patient with a liver tumor) had an elective replacement indicator after therapy that was not influenced by radiation. The mean distance from the proton beam to the CIED among devices that reset was 7.0 cm (range 0.9-8 cm), and the mean maximum neutron dose was 655 mSv (range 330-1100 mSv). All resets occurred in patients receiving thoracic PBT and were corrected without clinical incident. The generator for the defibrillator with the elective replacement indicator message was replaced uneventfully after treatment. Conclusions: The incidence of CIED resets was about 20% among patients receiving PBT to the thorax. We recommend that PBT be avoided in pacing-dependent patients and that patients with any type of CIED receiving

  20. Rationale and design of WEBCARE

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Spek, Viola; Theuns, Dominic A M J

    2009-01-01

    The implantable cardioverter defibrillator (ICD) is generally well accepted, but 25-33% of patients experience clinical levels of anxiety, depression, and impaired quality of life (QoL) following implantation. Few trials in ICD patients have investigated whether behavioral intervention may mitiga...

  1. The use of variability of repolarization for monitoring of arrhythmic risk : "the rocking of the boat"

    NARCIS (Netherlands)

    Oosterhoff, P.

    2011-01-01

    The majority of deaths in the western world are of cardiovascular origin. Approximately 60% of these cardiovascular deaths are sudden. Implantation of an implantable cardioverter defibrillator (ICD) has been proven effective in preventing sudden cardiac death in patients at increased risk. An ICD

  2. Optimal antiarrhythmic drug therapy for electrical storm

    OpenAIRE

    Sorajja, Dan; Munger, Thomas M.; Shen, Win-Kuang

    2015-01-01

    Abstract Electrical storm, defined as 3 or more separate episodes of ventricular tachycardia or ventricular fibrillation within 24?hours, carries significant morbidity and mortality. These unstable ventricular arrhythmias have been described with a variety of conditions including ischemic heart disease, structural heart disease, and genetic conditions. While implantable cardioverter defibrillator implantation and ablation may be indicated and required, antiarrhythmic medication remains an imp...

  3. Human Pluripotent Stem Cell Differentiation into Functional Epicardial Progenitor Cells

    NARCIS (Netherlands)

    Guadix, Juan Antonio; Orlova, Valeria V.; Giacomelli, Elisa; Bellin, Milena; Ribeiro, Marcelo C.; Mummery, Christine L.; Pérez-Pomares, José M.; Passier, Robert

    2017-01-01

    Human pluripotent stem cells (hPSCs) are widely used to study cardiovascular cell differentiation and function. Here, we induced differentiation of hPSCs (both embryonic and induced) to proepicardial/epicardial progenitor cells that cover the heart during development. Addition of retinoic acid (RA)

  4. Feasibility of remote magnetic navigation for epicardial ablation

    NARCIS (Netherlands)

    P. Abraham; L.D. Abkenari; E.C.H. Peters; T. Szili-Torok (Tamas)

    2013-01-01

    textabstractPercutaneous epicardial mapping and ablation is an emerging method to treat ventricular tachycardias (VT), premature ventricular complexes (PVC), and accessory pathways. The use of a remote magnetic navigation system (MNS) could enhance precision and maintain safety. This multiple case

  5. Unipolar atrial electrogram morphology from an epicardial and endocardial perspective.

    Science.gov (United States)

    van der Does, Lisette J M E; Knops, Paul; Teuwen, Christophe P; Serban, Corina; Starreveld, Roeliene; Lanters, Eva A H; Mouws, Elisabeth M J P; Kik, Charles; Bogers, Ad J J C; de Groot, Natasja M S

    2018-02-22

    Endo-epicardial asynchrony (EEA) and the interplay between the endocardial and epicardial layers could be important in the pathophysiology of atrial arrhythmias. The morphologic differences between epicardial and endocardial atrial electrograms have not yet been described, and electrogram morphology may hold information about the presence of EEA. The purpose of this study was to directly compare epicardial to endocardial unipolar electrogram morphology during sinus rhythm (SR) and to evaluate whether EEA contributes to electrogram fractionation by correlating fractionation to spatial activation patterns. In 26 patients undergoing cardiac surgery, unipolar electrograms were simultaneously recorded from the epicardium and endocardium at the inferior, middle, and superior right atrial (RA) free wall during SR. Potentials were analyzed for epi-endocardial differences in local activation time, voltage, RS ratio, and fractionation. The surrounding and opposite electrograms of fractionated deflections were evaluated for corresponding local activation times in order to determine whether fractionation originated from EEA. The superior RA was predisposed to delayed activation, EEA, and fractionation. Both epicardial and endocardial electrograms demonstrated an S-predominance. Fractionation was mostly similar between the 2 sides; however, incidentally deflections up to 4 mV on 1 side could be absent on the other side. Remote activation was responsible for most fractionated deflections (95%) in SR, of which 4% could be attributed to EEA. Local epi-endocardial differences in electrogram fractionation occur occasionally during SR but will likely increase during arrhythmias due to increasing EEA and (functional) conduction disorders. Electrogram fractionation can originate from EEA, and this study demonstrated that unipolar electrogram fractionation can potentially identify EEA. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  6. Preventing phrenic nerve stimulation by a patch insulation in an intact swine heart model.

    Directory of Open Access Journals (Sweden)

    Jin-Long Huang

    Full Text Available Phrenic nerve stimulation (PNS could be prevented by a silastic patch over the epicardial lead. We studied the effects in preventing PNS by placing a silastic patch directly over an epicardial lead or placing a graft around the phrenic nerve (PN.Fourteen Lanyu swine were enrolled. A bipolar lead was placed epicardially on the left ventricle (LV inferior to the PN. An implantable cardioverter-defibrillator (ICD lead was placed into the right ventricle (RV. The maximal influential distance (MID was measured under 3 pacing configurations to express the influential electrical field on the PN. The threshold of the LV and PN were evaluated epicardially. Then, PTFE patches of different sizes (10×10 mm, 20×20 mm and 30×30 mm were placed between the LV lead and PN to study the rise in PN threshold in 7 swine. On the other hand, the PN were surrounded by a PTFE graft of different lengths (10 mm, 20 mm, and 30 mm in the remaining 7 swine. LV-bipolar pacing showed the shortest MID when compared to the other 2 unipolar pacing configurations at pacing voltage of 10 V. The patch was most effective in preventing PNS during LV-bipolar pacing. PNS was prevented under all circumstances with a larger PTFE patch (30×30 mm or long graft (30 mm.PNS was avoided by placing a PTFE patch over the LV lead or a graft around the PN despite pacing configurations. Hence if PNS persisted during CRT implantation, a PTFE patch on the LV lead or a graft around the PN could be considered.

  7. Epicardial clip occlusion of the left atrial appendage during cardiac surgery provides optimal surgical results and long-term stability.

    Science.gov (United States)

    Kurfirst, Vojtech; Mokrácek, Aleš; Canádyová, Júlia; Frána, Radim; Zeman, Petr

    2017-07-01

    Occlusion of the left atrial appendage (LAA) has become an integral and important part of the surgical treatment of atrial fibrillation. Different methods of surgical occlusion of the LAA have been associated with varying levels of short- and long-term success for closure. The purpose of this study was to evaluate long-term results of epicardial placement and endocardial occlusion in patients undergoing cardiac operative procedures. A total of 101 patients (average age 65.7 years) undergoing cardiac operative procedures with the epicardial AtriClip Exclusion System of the LAA were enrolled in the study. The AtriClip was placed via a sternotomy or a thoracotomy or from a thoracoscopic approach. Postoperative variables, such as thromboembolic events, clip stability and endocardial leakage around the device, were examined by transoesophageal echocardiography (TEE) and/or computed tomography. Perioperative clip implantation was achieved in 98% of patients. TEE and/or computed tomography conducted during the follow-up period, comprising 1873 patient-months with a mean duration of 18 ± 11 months, revealed no clip migration, no leakage around the device and no clot formation near the remnant cul-de-sac. During the follow-up period, 4 of the cardiac patients experienced transitory ischaemic attacks, whereas no patient experienced a cerebrovascular attack. The Epicardial AtriClip Exclusion System of the LAA appears to be a feasable and safe operative method with a high success rate. Long-term follow-up confirmed clip stability, complete occlussion of the LAA and absence of any atrial fibrilation-related thromboembolic events. These results need to be confirmed by a larger, multicentre study. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  8. Analysis of implantable defibrillator longevity under clinical circumstances: implications for device selection.

    Science.gov (United States)

    Knops, Paul; Theuns, Dominic A M J; Res, Jan C J; Jordaens, Luc

    2009-10-01

    Information about implantable cardioverter-defibrillator (ICD) longevity is mostly calculated from measurements under ideal laboratory conditions. However, little information about longevity under clinical circumstances is available. This survey gives an overview on ICD service times and generator replacements in a cohort of consecutive ICD patients. Indications for replacement were classified as a normal end-of-service (EOS), premature EOS, system malfunction, infection and device advisory, or recall actions. From the premature and normal EOS group, longevity from single-chamber (SC), dual-chamber (DC), and cardiac resynchronization therapy defibrillator (CRT-D), rate-responsive (RR) settings, high output (HO) stimulation, and indication for ICD therapy was compared. Differences between brands were compared as well. In a total of 854 patients, 203 ICD replacements (165 patients) were recorded. Premature and normal EOS replacements consisted of 32 SC, 98 DC and 24 CRT-D systems. Longevity was significantly longer in SC systems compared to DC and CRT-D systems (54 +/- 19 vs. 40 +/- 17 and 42 +/- 15 months; P = 0.008). Longevity between non-RR (n = 143) and RR (n = 11) settings was not significantly different (43 +/- 18 vs. 45 +/- 13 months) as it also was not for HO versus non-HO stimulation (43 +/- 19 vs. 46 +/- 17 months). Longevity of ICDs was not significantly different between primary and secondary prevention (42 +/- 19 vs. 44 +/- 18 months). The average longevity on account of a device-based EOS message was 43 +/- 18 months. Average longevity for Biotronik (BIO, n = 72) was 33 +/- 10 months, for ELA Medical (ELA, n = 12) 44 +/- 17 months, for Guidant (GDT, n = 36) 49 +/- 12 months, for Medtronic (MDT, n = 29) 62 +/- 22 months, and for St. Jude Medical (SJM, n = 5) 31 +/- 9 months (P generators had a longer service time compared to DC and CRT-D systems. No influence of indication for ICD therapy and HO stimulation on generator longevity was observed in this

  9. Does ICD indication affect quality of life and levels of distress?

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Sears, Samuel F; Burg, Matthew M

    2009-01-01

    The implantable cardioverter defibrillator (ICD) is the treatment of choice for life-threatening arrhythmias, with ICD indications having recently been extended to include primary prophylaxis. Despite the medical benefits of the ICD, there is an ongoing debate as to the impact of the ICD on patie...

  10. Inappropriate shocks in the subcutaneous ICD: Incidence, predictors and management

    NARCIS (Netherlands)

    Olde Nordkamp, Louise R. A.; Brouwer, Tom F.; Barr, Craig; Theuns, Dominic A. M. J.; Boersma, Lucas V. A.; Johansen, Jens B.; Neuzil, Petr; Wilde, Arthur A. M.; Carter, Nathan; Husby, Michael; Lambiase, Pier D.; Knops, Reinoud E.

    2015-01-01

    The entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) eliminates the need for transvenous leads, and therefore has the potential to improve lead-longevity and reduce lead-related complications. The S-ICD has a morphology-based sensing algorithm of which inappropriate shocks have

  11. Wireless Heart Patients and the Quantified Self

    DEFF Research Database (Denmark)

    Grew, Julie Christina; Svendsen, Mette Nordahl

    2017-01-01

    Remote monitoring of implantable cardioverter defibrillator (ICD) patients links patients wirelessly to the clinic via a box in their bedroom. The box transmits data from the ICD to a remote database accessible to clinicians without patient involvement. Data travel across time and space; clinicia...

  12. Patient satisfaction and suggestions for improvement of remote ICD monitoring

    DEFF Research Database (Denmark)

    Petersen, Helen Høgh; Larsen, Mie Christa Jensen; Nielsen, Olav Wendelboe

    2012-01-01

    PURPOSE: The study aim was to evaluate patient acceptance and content with remote follow-up (FU) of their implantable cardioverter defibrillator (ICD) and to estimate patients' wish for changes in remote follow-up routines. METHODS: Four hundred seventy-four ICD patients at the device follow-up c...

  13. Katekolaminerg polymorf ventrikulaer takykardi er en sjaelden arvelig hjertesygdom

    DEFF Research Database (Denmark)

    Holst, Anders Gaarsdal; Tfelt-Hansen, Jacob; Olesen, Morten S

    2010-01-01

    or cardiac arrest. The arrhythmias are usually triggered by exercise or emotional affection. The diagnosis is often made using exercise electrocardiogram, which typically triggers arrhythmias. The treatment consists of beta blockers, frequently in combination with implantation of a cardioverter-defibrillator....

  14. Gender differences in psychological distress and quality of life in patients with an ICD 1-year postimplant

    NARCIS (Netherlands)

    Starrenburg, Annemieke; Pedersen, Susanne; van den Broek, K.C.; Kraaier, Karin; Scholten, Marcoen; Van der Palen, Job

    2014-01-01

    Background Gender differences in patient-reported outcomes in patients with an implantable cardioverter defibrillator (ICD) have been researched, but findings are inconclusive and mostly based on cross-sectional study designs. To gain a better insight into potential determinants of psychological

  15. Gender Differences in Psychological Distress and Quality of Life in Patients with an ICD 1-Year Postimplant

    NARCIS (Netherlands)

    Starrenburg, Annemieke H.; Pedersen, Susanne S.; van den Broek, Krista; Kraaier, Karin; Scholten, Marcoen; van der Palen, Jacobus Adrianus Maria

    2014-01-01

    Background Gender differences in patient-reported outcomes in patients with an implantable cardioverter defibrillator (ICD) have been researched, but findings are inconclusive and mostly based on cross-sectional study designs. To gain a better insight into potential determinants of psychological

  16. Designing Shared Electronic Records for Chronic Care

    DEFF Research Database (Denmark)

    Bansler, Jørgen Peter; Havn, Erling C.; Mønsted, Troels

    2010-01-01

    ICDs (implantable cardioverter-defibrillator). These are chronic patients who usually see several different healthcare providers on a regular basis. The main findings so far are: (1) Most of the data produced and recorded as part of the care process are context-specific and often difficult to interpret...

  17. New method for cardiac resynchronization therapy: Transapical endocardial lead implantation for left ventricular free wall pacing

    NARCIS (Netherlands)

    I. Kassai (Imre); C. Foldesi (Csaba); A. Szekely (Andrea); T. Szili-Torok (Tamas)

    2008-01-01

    textabstractCoronary sinus lead placement for transvenous left ventricular (LV) pacing in cardiac resynchronization therapy (CRT) has a significant failure rate at implant and a significant dislocation rate during follow-up. For these patients, epicardial pacing lead implantation is the most

  18. Aborted Sudden Cardiac Death in a Female Patient Presenting with Takotsubo-Like Cardiomyopathy due to Epicardial Coronary Vasospasm

    Directory of Open Access Journals (Sweden)

    Sorin Giusca

    2017-01-01

    Full Text Available Takotsubo cardiomyopathy is characterized by apical ballooning of the left ventricle (LV in the absence of relevant coronary artery stenosis, which typically occurs in elderly women after emotional stress. Catecholamine cardiotoxicity, metabolic disturbance, and coronary microvascular impairment have previously been proposed as underlying pathophysiologic mechanisms of takotsubo cardiomyopathy, whereas myocardial stunning resulting from epicardial coronary artery vasospasm is not generally accepted as a cause of takotsubo cardiomyopathy. The prognosis of takotsubo cardiomyopathy is generally more favourable compared to myocardial infarction; however, severe complications such as rupture of the LV and life-threatening arrhythmias may occur. Herein, we describe a case of an 84-year-old female, who presented with aborted sudden cardiac death due to ventricular fibrillation. Echocardiography suggested LV apical ballooning with severely impaired LV-function, so that takotsubo cardiomyopathy was suspected. However, coronary angiography revealed epicardial spasm of the left anterior ascending, which resolved after intracoronary injection of 0.2 mg nitroglycerine. Cardiac magnetic resonance exhibited subendocardial late enhancement and echocardiography showed normalization of LV dysfunction during follow-up. The patient was put on conservative treatment with nitrates and calcium inhibitors and ICD implantation were deferred.

  19. Human Pluripotent Stem Cell Differentiation into Functional Epicardial Progenitor Cells

    Directory of Open Access Journals (Sweden)

    Juan Antonio Guadix

    2017-12-01

    Full Text Available Summary: Human pluripotent stem cells (hPSCs are widely used to study cardiovascular cell differentiation and function. Here, we induced differentiation of hPSCs (both embryonic and induced to proepicardial/epicardial progenitor cells that cover the heart during development. Addition of retinoic acid (RA and bone morphogenetic protein 4 (BMP4 promoted expression of the mesodermal marker PDGFRα, upregulated characteristic (proepicardial progenitor cell genes, and downregulated transcription of myocardial genes. We confirmed the (proepicardial-like properties of these cells using in vitro co-culture assays and in ovo grafting of hPSC-epicardial cells into chick embryos. Our data show that RA + BMP4-treated hPSCs differentiate into (proepicardial-like cells displaying functional properties (adhesion and spreading over the myocardium of their in vivo counterpart. The results extend evidence that hPSCs are an excellent model to study (proepicardial differentiation into cardiovascular cells in human development and evaluate their potential for cardiac regeneration. : The authors have shown that hPSCs can be instructed in vitro to differentiate into a specific cardiac embryonic progenitor cell population called the proepicardium. Proepicardial cells are required for normal formation of the heart during development and might contribute to the development of cell-based therapies for heart repair. Keywords: human pluripotent stem cells, proepicardium, progenitor cells, cardiovascular, differentiation

  20. Enhanced Electrical Integration of Engineered Human Myocardium via Intramyocardial versus Epicardial Delivery in Infarcted Rat Hearts.

    Directory of Open Access Journals (Sweden)

    Kaytlyn A Gerbin

    Full Text Available Cardiac tissue engineering is a promising approach to provide large-scale tissues for transplantation to regenerate the heart after ischemic injury, however, integration with the host myocardium will be required to achieve electromechanical benefits. To test the ability of engineered heart tissues to electrically integrate with the host, 10 million human embryonic stem cell (hESC-derived cardiomyocytes were used to form either scaffold-free tissue patches implanted on the epicardium or micro-tissue particles (~1000 cells/particle delivered by intramyocardial injection into the left ventricular wall of the ischemia/reperfusion injured athymic rat heart. Results were compared to intramyocardial injection of 10 million dispersed hESC-cardiomyocytes. Graft size was not significantly different between treatment groups and correlated inversely with infarct size. After implantation on the epicardial surface, hESC-cardiac tissue patches were electromechanically active, but they beat slowly and were not electrically coupled to the host at 4 weeks based on ex vivo fluorescent imaging of their graft-autonomous GCaMP3 calcium reporter. Histologically, scar tissue physically separated the patch graft and host myocardium. In contrast, following intramyocardial injection of micro-tissue particles and suspended cardiomyocytes, 100% of the grafts detected by fluorescent GCaMP3 imaging were electrically coupled to the host heart at spontaneous rate and could follow host pacing up to a maximum of 300-390 beats per minute (5-6.5 Hz. Gap junctions between intramyocardial graft and host tissue were identified histologically. The extensive coupling and rapid response rate of the human myocardial grafts after intramyocardial delivery suggest electrophysiological adaptation of hESC-derived cardiomyocytes to the rat heart's pacemaking activity. These data support the use of the rat model for studying electromechanical integration of human cardiomyocytes, and they

  1. Single-slice epicardial fat area measurement. Do we need to measure the total epicardial fat volume?

    International Nuclear Information System (INIS)

    Oyama, Noriko; Goto, Daisuke; Ito, Yoichi M.

    2011-01-01

    The aim of this study was to assess a method for measuring epicardial fat volume (EFV) by means of a single-slice area measurement. We investigated the relation between a single-slice fat area measurement and total EFV. A series of 72 consecutive patients (ages 65±11 years; 36 men) who had undergone cardiac computed tomography (CT) on a 64-slice multidetector scanner with prospective electrocardiographic triggering were retrospectively reviewed. Pixels in the pericardium with a density range from -230 to -30 Hounsfield units were considered fat, giving the per-slice epicardial fat area (EFA). The EFV was estimated by the summation of EFAs multiplied by the slice thickness. We investigated the relation between total EFV and each EFA. EFAs measured at several anatomical landmarks - right pulmonary artery, origins of the left main coronary artery, right coronary artery, coronary sinus - all correlated with the EFV (r=0.77-0.92). The EFA at the LMCA level was highly reproducible and showed an excellent correlation with the EFV (r=0.92). The EFA is significantly correlated with the EFV. The EFA is a simple, quick method for representing the time-consuming EFV, which has been used as a predictive indicator of cardiovascular diseases. (author)

  2. Direct Proof of Endo-Epicardial Asynchrony of the Atrial Wall During Atrial Fibrillation in Humans.

    Science.gov (United States)

    de Groot, Natasja; van der Does, Lisette; Yaksh, Ameeta; Lanters, Eva; Teuwen, Christophe; Knops, Paul; van de Woestijne, Pieter; Bekkers, Jos; Kik, Charles; Bogers, Ad; Allessie, Maurits

    2016-05-01

    The presence of focal fibrillation waves during atrial fibrillation (AF) can, besides ectopic activity, also be explained by asynchronous activation of the atrial endo- and epicardial layer and transmurally propagating fibrillation waves. To provide direct proof of endo-epicardial asynchrony, we performed simultaneous high-resolution mapping of the right atrial endo- and epicardial wall during AF in humans. Intraoperative mapping of the endo- and epicardial right atrial wall was performed during (induced) AF in 10 patients with AF (paroxysmal: n=3; persistent: n=4; and longstanding persistent: n=3) and 4 patients without a history of AF. A clamp made of 2 rectangular 8×16 electrode arrays (interelectrode distance 2 mm) was inserted into the incision in the right atrial appendage. Recordings of 10 seconds of AF were analyzed to determine the incidence of asynchronous endo-epicardial activation times (≥15 ms) of opposite electrodes. Asynchronous endo-epicardial activation ranged between 0.9 and 55.9% without preference for either side. Focal waves appeared equally frequent at endocardium and epicardium (11% versus 13%; ITALIC! P=0.18). Using strict criteria for breakthrough (presence of an opposite wave within 4 mm and ≤14 ms before the origin of the focal wave), the majority (65%) of all focal fibrillation waves could be attributed to endo-epicardial excitation. We provided the first evidence for asynchronous activation of the endo-epicardial wall during AF in humans. Endo-epicardial asynchrony may play a major role in the pathophysiology of AF and may offer an explanation why in some patients therapy fails. © 2016 American Heart Association, Inc.

  3. Inverse electrocardiographic transformations: dependence on the number of epicardial regions and body surface data points.

    Science.gov (United States)

    Johnston, P R; Walker, S J; Hyttinen, J A; Kilpatrick, D

    1994-04-01

    The inverse problem of electrocardiography, the computation of epicardial potentials from body surface potentials, is influenced by the desired resolution on the epicardium, the number of recording points on the body surface, and the method of limiting the inversion process. To examine the role of these variables in the computation of the inverse transform, Tikhonov's zero-order regularization and singular value decomposition (SVD) have been used to invert the forward transfer matrix. The inverses have been compared in a data-independent manner using the resolution and the noise amplification as endpoints. Sets of 32, 50, 192, and 384 leads were chosen as sets of body surface data, and 26, 50, 74, and 98 regions were chosen to represent the epicardium. The resolution and noise were both improved by using a greater number of electrodes on the body surface. When 60% of the singular values are retained, the results show a trade-off between noise and resolution, with typical maximal epicardial noise levels of less than 0.5% of maximum epicardial potentials for 26 epicardial regions, 2.5% for 50 epicardial regions, 7.5% for 74 epicardial regions, and 50% for 98 epicardial regions. As the number of epicardial regions is increased, the regularization technique effectively fixes the noise amplification but markedly decreases the resolution, whereas SVD results in an increase in noise and a moderate decrease in resolution. Overall the regularization technique performs slightly better than SVD in the noise-resolution relationship. There is a region at the posterior of the heart that was poorly resolved regardless of the number of regions chosen. The variance of the resolution was such as to suggest the use of variable-size epicardial regions based on the resolution.

  4. Epicardial adipose tissue is associated with visceral fat, metabolic syndrome, and insulin resistance in menopausal women.

    Science.gov (United States)

    Fernández Muñoz, María J; Basurto Acevedo, Lourdes; Córdova Pérez, Nydia; Vázquez Martínez, Ana Laura; Tepach Gutiérrez, Nayive; Vega García, Sara; Rocha Cruz, Alberto; Díaz Martínez, Alma; Saucedo García, Renata; Zárate Treviño, Arturo; González Escudero, Eduardo Alberto; Degollado Córdova, José Antonio

    2014-06-01

    Epicardial adipose tissue has been associated with several obesity-related parameters and with insulin resistance. Echocardiographic assessment of this tissue is an easy and reliable marker of cardiometabolic risk. However, there are insufficient studies on the relationship between epicardial fat and insulin resistance during the postmenopausal period, when cardiovascular risk increases in women. The objective of this study was to examine the association between epicardial adipose tissue and visceral adipose tissue, waist circumference, body mass index, and insulin resistance in postmenopausal women. A cross sectional study was conducted in 34 postmenopausal women with and without metabolic syndrome. All participants underwent a transthoracic echocardiogram and body composition analysis. A positive correlation was observed between epicardial fat and visceral adipose tissue, body mass index, and waist circumference. The values of these correlations of epicardial fat thickness overlying the aorta-right ventricle were r = 0.505 (P < .003), r = 0.545 (P < .001), and r = 0.515 (P < .003), respectively. Epicardial adipose tissue was higher in postmenopausal women with metabolic syndrome than in those without this syndrome (mean [standard deviation], 544.2 [122.9] vs 363.6 [162.3] mm(2); P = .03). Epicardial fat thickness measured by echocardiography was associated with visceral adipose tissue and other obesity parameters. Epicardial adipose tissue was higher in postmenopausal women with metabolic syndrome. Therefore, echocardiographic assessment of epicardial fat may be a simple and reliable marker of cardiovascular risk in postmenopausal women. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  5. Infected Congenital Epicardial Cyst Presenting as Acute Abdomen.

    Science.gov (United States)

    Dribin, Timothy; Files, Matthew D; Rudzinski, Erin R; Kaplan, Ron; Stone, Kimberly P

    2016-12-01

    A previously healthy 3-year-old boy presented to the emergency department with abdominal pain, fever, and emesis. Laboratory and radiologic evaluation for causes of acute abdomen were negative; however, review of the abdominal x-ray demonstrated cardiomegaly with the subsequent diagnosis of pericardial cyst by echocardiogram and computed tomography. The patient underwent surgical decompression and attempted removal of the cystic structure revealing that the cyst originated from the epicardium. His abdominal pain and fever resolved postoperatively and he completed a 3-week course of ceftriaxone for treatment of Propionibacterium acnes infected congenital epicardial cyst. Emergency department physicians must maintain a broad differential in patients with symptoms of acute abdomen to prevent complications from serious cardiac or pulmonary diseases that present with symptoms of referred abdominal pain.

  6. Systolic Compression of Epicardial Coronary and Intramural Arteries

    Science.gov (United States)

    Mohiddin, Saidi A.; Fananapazir, Lameh

    2002-01-01

    It has been suggested that systolic compression of epicardial coronary arteries is an important cause of myocardial ischemia and sudden death in children with hypertrophic cardiomyopathy. We examined the associations between sudden death, systolic coronary compression of intra- and epicardial arteries, myocardial perfusion abnormalities, and severity of hypertrophy in children with hypertrophic cardiomyopathy. We reviewed the angiograms from 57 children with hypertrophic cardiomyopathy for the presence of coronary and septal artery compression; coronary compression was present in 23 (40%). The left anterior descending artery was most often affected, and multiple sites were found in 4 children. Myocardial perfusion abnormalities were more frequently present in children with coronary compression than in those without (94% vs 47%, P = 0.002). Coronary compression was also associated with more severe septal hypertrophy and greater left ventricular outflow gradient. Septal branch compression was present in 65% of the children and was significantly associated with coronary compression, severity of septal hypertrophy, and outflow obstruction. Multivariate analysis showed that septal thickness and septal branch compression, but not coronary compression, were independent predictors of perfusion abnormalities. Coronary compression was not associated with symptom severity, ventricular tachycardia, or a worse prognosis. We conclude that compression of coronary arteries and their septal branches is common in children with hypertrophic cardiomyopathy and is related to the magnitude of left ventricular hypertrophy. Our findings suggest that coronary compression does not make an important contribution to myocardial ischemia in hypertrophic cardiomyopathy; however, left ventricular hypertrophy and compression of intramural arteries may contribute significantly. (Tex Heart Inst J 2002;29:290–8) PMID:12484613

  7. Combined etiology of anaphylactic cardiogenic shock: Amiodarone, epinephrine, cardioverter defibrillator, left ventricular assist devices and the Kounis syndrome

    Directory of Open Access Journals (Sweden)

    Nicholas G Kounis

    2015-01-01

    Full Text Available Anaphylactic shock is a life-threatening condition which needs detailed and mediculous clinical assessment and thoughtful treatment. Several causes can join forces in order to degranulate mast cells. Amiodarone which is an iodine-containing highly lipophilic benzofuran can induce allergic reactions and anaphylactic shock in sensitized patients. Epinephrine is a life saving drug, but in sulfite allergic patients it should be given with caution due its metabisulfite preservative. Metals covering cardiac defibrillators and pacemakers can act as antigens attached to serum proteins and induce allergic reactions. In anaphylactic shock, myocardial involvement due to vasospasm-induced coronary blood flow reduction manifesting as Kounis syndrome should be always considered. Clinically, combined treatment targeting the primary cause of anaphylaxis together with protection of cardiac tissue seems to be of paramount importance.

  8. Epicardial oesophageal duplication with hiatal hernia in a case of Turner's syndrome

    International Nuclear Information System (INIS)

    Tamburrini, O.; Cigliano, S.; Esposito, G.; Cucchiara, S.

    1983-01-01

    The authors of this paper report the first case of epicardial oesophageal duplication causing hiatal hernia in a patient afflicted with Turner's syndrome, and they discuss its possible etiology. (orig.)

  9. [Arrhythmogenic right ventricular cardiomyopathy. Case report and a brief literature review].

    Science.gov (United States)

    Izurieta, Carlos; Curotto-Grasiosi, Jorge; Rocchinotti, Mónica; Torres, María J; Moranchel, Manuel; Cañas, Sebastián; Cardús, Marta E; Alasia, Diego; Cordero, Diego J; Angel, Adriana

    2013-01-01

    A 51-year-old man was admitted to this hospital because of palpitations and a feeling of dizziness for a period of 2h. The electrocardiogram revealed a regular wide-QRS complex tachycardia at a rate of 250 beats per minute, with superior axis and left bundle branch block morphology without hemodynamically decompensation, the patient was cardioverted to sinus rhythm after the administration of a loading and maintenance dose of amiodarone. The elechtrophysiological study showed the ventricular origin of the arrhythmia. In order to diagnose the etiology of the ventricular tachycardia we performed a coronary arteriography that showed normal epicardial vessels, thus ruling out coronary disease. Doppler echocardiography revealed systolic and diastolic functions of both left and right ventricles within normal parameters, and normal diameters as well. A cardiac magnetic resonance with late enhancement was done, showing structural abnormalities of the right ventricle wall with moderate impairment of the ejection fraction, and a mild dysfunction of the left ventricle. The diagnosis of arrhythmogenic right ventricular cardiomyopathy was performed as 2 major Task Force criteria were met. We implanted an automatic cardioverter defibrillator as a prophylactic measure. The patient was discharged without complications. Copyright © 2012 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  10. Conservative Management of an Epicardial Collateral Perforation During Retrograde Chronic Total Occlusion Percutaneous Coronary Intervention.

    Science.gov (United States)

    Ngo, Christian; Christopoulos, George; Brilakis, Emmanouil S

    2016-01-01

    Coronary artery perforation is a highly feared complication of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) and can lead to pericardial effusion, tamponade, and, rarely, emergent cardiac surgery. Perforation of epicardial collaterals during retrograde CTO-PCI may be particularly challenging to treat, as embolization from both sides of the perforation may be required to control the bleeding. However, conservative measures can occasionally be effective. We present a case of epicardial collateral vessel perforation that was managed conservatively with anticoagulation reversal.

  11. Usefulness of Epicardial Area in the Short Axis to Identify Elevated Left Ventricular Mass in Men.

    Science.gov (United States)

    Fitzpatrick, Jesse K; Cohen, Beth E; Rosenblatt, Andrew; Shaw, Richard E; Schiller, Nelson B

    2018-06-15

    Left ventricular (LV) hypertrophy is strongly associated with increased cardiovascular morbidity and mortality. The 2-dimensional LV mass algorithms suffer from measurement variability that can lead to misclassification of patients with LV hypertrophy as normal, or vice versa. Among the 4 echocardiographic measurements required by the 2-dimensional LV mass algorithms, epicardial and endocardial area have the lowest interobserver variation and could be used to corroborate LV mass calculations. We sought cut-off values that are able to discriminate between elevated and normal LV mass based on endocardial or epicardial area alone. Using data from 664 men enrolled in the Mind Your Heart Study, we calculated the correlation of LV mass index with epicardial area and endocardial area. We then used receiver operator characteristic curves to identify epicardial and endocardial area cut-points that could discriminate subjects with normal LV mass and LV hypertrophy. LV mass index was more strongly correlated with epicardial area compared with endocardial area, r = 0.70 versus r = 0.27, respectively. Epicardial area had a significantly higher area under the receiver operator characteristic curve (p versus 0.63 (95% confidence interval 0.57 to 0.71). An epicardial area cut-point of ≥38.0 cm 2 corresponded to a sensitivity of 95.0% and specificity of 54.4% for detecting LV hypertrophy. In conclusion, epicardial area showed promise as a method of rapid screening for LV hypertrophy and could be used to validate formal LV mass calculations. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. The devices for electrotherapy of the heart, compatible with magnetic resonance tomography

    OpenAIRE

    Glushko L.A.; Bockeria O.L.

    2015-01-01

    Over the past 50 years the clinical practice is supported by technological developments in the field of diagnosis and treatment of patients with cardiovascular diseases. The evolution of implantable pacemakers in the middle of the XX century, and the world's first implantation of a cardioverter-defibrillator in 1980 has improved the quality and duration of life of millions of patients worldwide. These implantable devices for cardiac electrotherapy now have not only therapeutic, but also diagn...

  13. Relationship Between Neck Circumference and Epicardial Fat Thickness in a Healthy Male Population

    Directory of Open Access Journals (Sweden)

    Uğur Küçük

    2016-01-01

    Full Text Available Abstract Background: Epicardial fat is an upper body visceral fat depot that may play a significant role in the development of adverse metabolic and cardiovascular risk profiles. There is a significant direct relationship between the amount of epicardial fat and general body adiposity (body mass index, BMI, but data regarding subcutaneous adiposity is limited. Objective: We conducted a study to determine the association between neck circumference and epicardial fat thickness in healthy young male individuals, and assess their individual correlations with general body adiposity and cardiometabolic risk factors. Methods: One hundred consecutive male patients aged 18 years or older with no known major medical conditions were included in the study. All participants underwent detailed physical examination including measurement of blood pressure, weight, height, waist/hip ratio, and neck circumference. Blood was collected to determine fasting glucose and lipid parameters. A standard echocardiographic examination was performed with additional epicardial fat thickness determination. Results: Among 100 study participants, neck circumference correlated significantly with weight, waist circumference, BMI, blood glucose, serum total cholesterol, low-density (LDL-cholesterol, and triglycerides levels. No significant correlation was found between neck circumference and high-density lipoprotein (HDL-cholesterol levels. Neck circumference correlated moderately and positively with echocardiographic epicardial fat thickness. Conclusion: Among patients with low cardiometabolic risk, increased neck circumference was associated with increased epicardial fat thickness.

  14. Association between epicardial fat volume and coronary plaques diagnosed by multislice computed tomography

    Directory of Open Access Journals (Sweden)

    José A. Morán Quijada

    2016-01-01

    Full Text Available Introduction: Coronary atherosclerotic disease is a major cause of death in Cuba and elsewhere. The volume of epicardial fat is considered a new cardiovascular risk factor because of its association with coronary atherogenesis.Objective: To determine, by multislice computed tomography, the association between epicardial fat volume and the presence of coronary atherosclerotic plaques.Method: A descriptive study was conducted with a universe of 130 patients with chest pain suggestive of ischemic heart disease, of which 117 were selected by opinion sampling. These patients underwent a calcium score study, a coronary angiography and a measurement of the epicardial fat volume.Results: Male patients predominated (54.7% and those aged 60-69 years (32.5%. A high volume of epicardial fat was found in 51.3% of patients, affecting 52.8% of women; 78.9% of patients with a calcium score between 100 and 399 UH had a high volume of epicardial fat, just as 71.2% of those with plaques and 100% of those with 4 or 5 plaques; 41% of patients had various types of plaque, which were mainly located in the anterior descending artery (88.1%.Conclusions: The measurement of the volume of epicardial fat is a useful tool to estimate the presence of coronary disease. When it was high, it was associated with older age, female gender and the presence of a higher calcium score, more plaques, more injuries and a greater involvement of the anterior descending artery.

  15. An increase in epicardial fat in women is associated with thrombotic risk.

    Science.gov (United States)

    Basurto Acevedo, Lourdes; Barrera Hernández, Susana; Fernández Muñoz, María de Jesús; Saucedo García, Renata Patricia; Rodríguez Luna, Ana Karen; Martínez Murillo, Carlos

    2018-01-29

    A decrease in fibrinolytic activity and an increase in the thickness of the epicardial adipose tissue have been observed in patients with coronary artery disease. The aim of this study was to determine the association between epicardial adipose tissue and fibrinolytic activity by measuring the concentration of plasminogen activator inhibitor-1 (PAI-1). A cross-sectional study was conducted on 56 apparently healthy women aged 45 to 60 years. Anthropometric measurements and biochemical determinations were performed on all participants. The fibrinolytic activity was determined by measuring PAI-1 by ELISA. Epicardial thickness was assessed by transthoracic echocardiography. The concentration of PAI-1 was directly associated with the thickness of the epicardial adipose tissue (r=0.475, P=.001), body mass index (BMI), visceral adipose tissue, insulin resistance, glucose, and HDL-cholesterol. The multivariate regression analysis indicated that epicardial fat independently predicts the concentrations of PAI-1. Women with thicker epicardial adipose tissue have reduced fibrinolytic activity, and consequently greater thrombotic risk. Copyright © 2017 Sociedad Española de Arteriosclerosis. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. The correlation between difference in foreign body reaction between implant locations and cytokine and MMP expression

    NARCIS (Netherlands)

    Luttikhuizen, Daniel T.; van Amerongen, Machteld J.; de Feijter, Pieter C.; Petersen, Arien H.; Harmsen, Martin C.; van Luyn, Marja J. A.

    2006-01-01

    The foreign body reaction (FBR) differs between subcutaneously and supra-epicardially implanted materials. We hypothesize that this is a result of differences in cytokine, chemokine and matrix metalloproteinase (MNIP) dynamics. Therefore we applied collagen disks subcutaneously and on the epicardium

  17. Computerized analysis of the 12-lead electrocardiogram to identify epicardial ventricular tachycardia exit sites.

    Science.gov (United States)

    Yokokawa, Miki; Jung, Dae Yon; Joseph, Kim K; Hero, Alfred O; Morady, Fred; Bogun, Frank

    2014-11-01

    Twelve-lead electrocardiogram (ECG) criteria for epicardial ventricular tachycardia (VT) origins have been described. In patients with structural heart disease, the ability to predict an epicardial origin based on QRS morphology is limited and has been investigated only for limited regions in the heart. The purpose of this study was to determine whether a computerized algorithm is able to accurately differentiate epicardial vs endocardial origins of ventricular arrhythmias. Endocardial and epicardial pace-mapping were performed in 43 patients at 3277 sites. The 12-lead ECGs were digitized and analyzed using a mixture of gaussian model (MoG) to assess whether the algorithm was able to identify an epicardial vs endocardial origin of the paced rhythm. The MoG computerized algorithm was compared to algorithms published in prior reports. The computerized algorithm correctly differentiated epicardial vs endocardial pacing sites for 80% of the sites compared to an accuracy of 42% to 66% of other described criteria. The accuracy was higher in patients without structural heart disease than in those with structural heart disease (94% vs 80%, P = .0004) and for right bundle branch block (82%) compared to left bundle branch block morphologies (79%, P = .001). Validation studies showed the accuracy for VT exit sites to be 84%. A computerized algorithm was able to accurately differentiate the majority of epicardial vs endocardial pace-mapping sites. The algorithm is not region specific and performed best in patients without structural heart disease and with VTs having a right bundle branch block morphology. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  18. Epicardial Fat: Definition, Measurements and Systematic Review of Main Outcomes

    International Nuclear Information System (INIS)

    Bertaso, Angela Gallina; Bertol, Daniela; Duncan, Bruce Bartholow; Foppa, Murilo

    2013-01-01

    Epicardial fat (EF) is a visceral fat deposit, located between the heart and the pericardium, which shares many of the pathophysiological properties of other visceral fat deposits, It also potentially causes local inflammation and likely has direct effects on coronary atherosclerosis. Echocardiography, computed tomography and magnetic resonance imaging have been used to evaluate EF, but variations between methodologies limit the comparability between these modalities. We performed a systematic review of the literature finding associations of EF with metabolic syndrome and coronary artery disease. The summarization of these associations is limited by the heterogeneity of the methods used and the populations studied, where most of the subjects were at high cardiovascular disease risk. EF is also associated with other known factors, such as obesity, diabetes mellitus, age and hypertension, which makes the interpretation of its role as an independent risk marker intricate. Based on these data, we conclude that EF is a visceral fat deposit with potential implications in coronary artery disease. We describe the reference values of EF for the different imaging modalities, even though these have not yet been validated for clinical use. It is still necessary to better define normal reference values and the risk associated with EF to further evaluate its role in cardiovascular and metabolic risk assessment in relation to other criteria currently used

  19. Automatic detection and classification of human epicardial atrial unipolar electrograms

    International Nuclear Information System (INIS)

    Dubé, B; Vinet, A; Xiong, F; Yin, Y; LeBlanc, A-R; Pagé, P

    2009-01-01

    This paper describes an unsupervised signal processing method applied to three-channel unipolar electrograms recorded from human atria. These were obtained by epicardial wires sutured on the right and left atria after coronary artery bypass surgery. Atrial (A) and ventricular (V) activations had to be detected and identified on each channel, and gathered across the channels when belonging to the same global event. The algorithm was developed and optimized on a training set of 19 recordings of 5 min. It was assessed on twenty-seven 2 h recordings taken just before the onset of a prolonged atrial fibrillation for a total of 1593697 activations that were validated and classified as normal atrial or ventricular activations (A, V) and premature atrial or ventricular activations (PAA, PVA). 99.93% of the activations were detected, and amongst these, 99.89% of the A and 99.75% of the V activations were correctly labelled. In the subset of the 39705 PAA, 99.83% were detected and 99.3% were correctly classified as A. The false positive rate was 0.37%. In conclusion, a reliable fully automatic detection and classification algorithm was developed that can detect and discriminate A and V activations from atrial recordings. It can provide the time series needed to develop a monitoring system aiming to identify dynamic predictors of forthcoming cardiac events such as postoperative atrial fibrillation

  20. Epicardial Fat: Definition, Measurements and Systematic Review of Main Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Bertaso, Angela Gallina [Programa de Pós-Graduação em Ciências da Saúde: Cardiologia e Ciências Cardiovasculares - Universidade Federal do Rio Grande do Sul, Porto Alegre (Brazil); Bertol, Daniela [Programa de Pós-Graduação em Epidemiologia - Universidade Federal do Rio Grande do Sul, Porto Alegre (Brazil); Duncan, Bruce Bartholow; Foppa, Murilo, E-mail: mfoppa@cardiol.br [Programa de Pós-Graduação em Ciências da Saúde: Cardiologia e Ciências Cardiovasculares - Universidade Federal do Rio Grande do Sul, Porto Alegre (Brazil); Programa de Pós-Graduação em Epidemiologia - Universidade Federal do Rio Grande do Sul, Porto Alegre (Brazil)

    2013-07-15

    Epicardial fat (EF) is a visceral fat deposit, located between the heart and the pericardium, which shares many of the pathophysiological properties of other visceral fat deposits, It also potentially causes local inflammation and likely has direct effects on coronary atherosclerosis. Echocardiography, computed tomography and magnetic resonance imaging have been used to evaluate EF, but variations between methodologies limit the comparability between these modalities. We performed a systematic review of the literature finding associations of EF with metabolic syndrome and coronary artery disease. The summarization of these associations is limited by the heterogeneity of the methods used and the populations studied, where most of the subjects were at high cardiovascular disease risk. EF is also associated with other known factors, such as obesity, diabetes mellitus, age and hypertension, which makes the interpretation of its role as an independent risk marker intricate. Based on these data, we conclude that EF is a visceral fat deposit with potential implications in coronary artery disease. We describe the reference values of EF for the different imaging modalities, even though these have not yet been validated for clinical use. It is still necessary to better define normal reference values and the risk associated with EF to further evaluate its role in cardiovascular and metabolic risk assessment in relation to other criteria currently used.

  1. New method for imaging epicardial motion with scattered radiation

    International Nuclear Information System (INIS)

    Tilley, D.G.

    1976-01-01

    A new method for monitoring cardiac motion is described which employs the secondary radiation emerging from the thorax during fluoroscopic x-ray examination of the heart. The motion of selected points on the heart's epicardial surface can be investigated by detecting the intensity variations of radiation scattered in the local vicinity of the heart-lung border. Also discussed are the radiation detectors and signal processing electronics used to produce a voltage analog depicting the periodic displacements of the heart surface. Digital data processing methods are described which are used to accomplish a transformation from a time scale for representing surface motion, to a frequency scale that is better suited for the quantitative analysis of the heart's myocardial dynamics. The dynamic radiographic technique is compared to other methods such as electrocardiography, phonocardiography, radarkymography, and echocardiography; which are also used to sense the dynamic state of the heart. A three-dimensional Monte Carlo computer code is used to investigate the transport of x-radiation in the canine thorax. The Monte Carlo computer studies are used to explore the capabilities and limitations of the dynamic radiograph as it is used to sense motions of the canine heart. Animal studies were conducted with the dynamic radiograph to determine the reproducibility of the examination procedure. Canine case studies are reported showing the effects of increased myocardial contractility resulting from intervention with these inotropic agents

  2. Torsades de Pointes associated with QT prolongation after catheter ablation of paroxysmal atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Yae Min Park

    2017-09-01

    Full Text Available A 79-year-old woman who underwent catheter ablation for paroxysmal atrial fibrillation presented with Torsades de Pointes (TdP. Aggravation of prolonged QT interval which is most likely due to neural modulation by catheter ablation, played major role in the initiation of TdP. The patient was successfully treated with isoproterenol during acute stage and discharged after stabilization without implantation of permanent pacemaker or implantable cardioverter defibrillator.

  3. Simultaneous Epicardial and Noncontact Endocardial Mapping of the Canine Right Atrium: Simulation and Experiment

    Science.gov (United States)

    Sabouri, Sepideh; Matene, Elhacene; Vinet, Alain; Richer, Louis-Philippe; Cardinal, René; Armour, J. Andrew; Pagé, Pierre; Kus, Teresa; Jacquemet, Vincent

    2014-01-01

    Epicardial high-density electrical mapping is a well-established experimental instrument to monitor in vivo the activity of the atria in response to modulations of the autonomic nervous system in sinus rhythm. In regions that are not accessible by epicardial mapping, noncontact endocardial mapping performed through a balloon catheter may provide a more comprehensive description of atrial activity. We developed a computer model of the canine right atrium to compare epicardial and noncontact endocardial mapping. The model was derived from an experiment in which electroanatomical reconstruction, epicardial mapping (103 electrodes), noncontact endocardial mapping (2048 virtual electrodes computed from a 64-channel balloon catheter), and direct-contact endocardial catheter recordings were simultaneously performed in a dog. The recording system was simulated in the computer model. For simulations and experiments (after atrio-ventricular node suppression), activation maps were computed during sinus rhythm. Repolarization was assessed by measuring the area under the atrial T wave (ATa), a marker of repolarization gradients. Results showed an epicardial-endocardial correlation coefficients of 0.80 and 0.63 (two dog experiments) and 0.96 (simulation) between activation times, and a correlation coefficients of 0.57 and 0.46 (two dog experiments) and 0.92 (simulation) between ATa values. Despite distance (balloon-atrial wall) and dimension reduction (64 electrodes), some information about atrial repolarization remained present in noncontact signals. PMID:24598778

  4. Is epicardial adipose tissue, assessed by echocardiography, a reliable method for visceral adipose tissue prediction?

    Science.gov (United States)

    Silaghi, Alina Cristina; Poantă, Laura; Valea, Ana; Pais, Raluca; Silaghi, Horatiu

    2011-03-01

    Epicardial adipose tissue is an ectopic fat storage at the heart surface in direct contact with the coronary arteries. It is considered a metabolically active tissue, being a local source of pro-inflammatory factors that contribute to the pathogenesis of coronary artery disease. The AIM of our study was to establish correlations between echocardiographic assessment of epicardial adipose tissue and anthropometric and ultrasound measurements of the central and peripheral fat depots. The study was conducted on 22 patients with or without coronaropathy. Epicardial adipose tissue was measured using Aloka Prosound α 10 machine with a 3.5-7.5 MHz variable-frequency transducer and subcutaneous and visceral fat with Esaote Megas GPX machine and 3.5-7.5 MHz variable frequency transducer. Epicardial adipose tissue measured by echocardiography is correlated with waist circumference (p < 0.05), visceral adipose tissue thickness measured by ultrasonography (US) and is not correlated with body mass index (p = 0.315), hip and thigh circumference or subcutaneous fat thickness measured by US. Our study confirms that US assessment of epicardial fat correlates with anthropometric and US measurements of the central fat, representing an indirect but reliable marker of the visceral fat.

  5. Simultaneous epicardial and noncontact endocardial mapping of the canine right atrium: simulation and experiment.

    Science.gov (United States)

    Sabouri, Sepideh; Matene, Elhacene; Vinet, Alain; Richer, Louis-Philippe; Cardinal, René; Armour, J Andrew; Pagé, Pierre; Kus, Teresa; Jacquemet, Vincent

    2014-01-01

    Epicardial high-density electrical mapping is a well-established experimental instrument to monitor in vivo the activity of the atria in response to modulations of the autonomic nervous system in sinus rhythm. In regions that are not accessible by epicardial mapping, noncontact endocardial mapping performed through a balloon catheter may provide a more comprehensive description of atrial activity. We developed a computer model of the canine right atrium to compare epicardial and noncontact endocardial mapping. The model was derived from an experiment in which electroanatomical reconstruction, epicardial mapping (103 electrodes), noncontact endocardial mapping (2048 virtual electrodes computed from a 64-channel balloon catheter), and direct-contact endocardial catheter recordings were simultaneously performed in a dog. The recording system was simulated in the computer model. For simulations and experiments (after atrio-ventricular node suppression), activation maps were computed during sinus rhythm. Repolarization was assessed by measuring the area under the atrial T wave (ATa), a marker of repolarization gradients. Results showed an epicardial-endocardial correlation coefficients of 0.80 and 0.63 (two dog experiments) and 0.96 (simulation) between activation times, and a correlation coefficients of 0.57 and 0.46 (two dog experiments) and 0.92 (simulation) between ATa values. Despite distance (balloon-atrial wall) and dimension reduction (64 electrodes), some information about atrial repolarization remained present in noncontact signals.

  6. Simultaneous epicardial and noncontact endocardial mapping of the canine right atrium: simulation and experiment.

    Directory of Open Access Journals (Sweden)

    Sepideh Sabouri

    Full Text Available Epicardial high-density electrical mapping is a well-established experimental instrument to monitor in vivo the activity of the atria in response to modulations of the autonomic nervous system in sinus rhythm. In regions that are not accessible by epicardial mapping, noncontact endocardial mapping performed through a balloon catheter may provide a more comprehensive description of atrial activity. We developed a computer model of the canine right atrium to compare epicardial and noncontact endocardial mapping. The model was derived from an experiment in which electroanatomical reconstruction, epicardial mapping (103 electrodes, noncontact endocardial mapping (2048 virtual electrodes computed from a 64-channel balloon catheter, and direct-contact endocardial catheter recordings were simultaneously performed in a dog. The recording system was simulated in the computer model. For simulations and experiments (after atrio-ventricular node suppression, activation maps were computed during sinus rhythm. Repolarization was assessed by measuring the area under the atrial T wave (ATa, a marker of repolarization gradients. Results showed an epicardial-endocardial correlation coefficients of 0.80 and 0.63 (two dog experiments and 0.96 (simulation between activation times, and a correlation coefficients of 0.57 and 0.46 (two dog experiments and 0.92 (simulation between ATa values. Despite distance (balloon-atrial wall and dimension reduction (64 electrodes, some information about atrial repolarization remained present in noncontact signals.

  7. Endocardial Pacemaker Implantation in Neonates and Infants

    Directory of Open Access Journals (Sweden)

    Canan Ayabakan

    2006-04-01

    Full Text Available Transvenous pacemaker lead implantation is the preferred method of pacing in adult patients. Lead performance and longevity are superior and the implantation approach can be performed under local anaesthetic with a very low morbidity. In children, and especially in neonates and infants, the epicardial route was traditionally chosen until the advent of smaller generators and lead implantation techniques that allowed growth of the child without lead displacement. Endocardial implantation is not universally accepted, however, as there is an incidence of venous occlusion of the smaller veins of neonates and infants with concerns for loss of venous access in the future. Growing experience with lower profile leads, however, reveals that endocardial pacing too can be performed with low morbidity and good long-term results in neonates and infants.

  8. Epicardial Ablation: Prevention of Phrenic Nerve Damage by Pericardial Injection of Saline and the Use of a Steerable Sheath

    Directory of Open Access Journals (Sweden)

    Kars Neven, MD

    2014-03-01

    Full Text Available Because of the close proximity of the phrenic nerve to the pericardium, phrenic nerve damage caused by epicardial ablation can easily occur. We report two cases of epicardial VT ablation where pericardial injection of saline, combined with the use of a steerable sheath, successfully prevents the phrenic nerve from being damaged.

  9. Epicardial, Biatrial Ablation With Integrated Uni-bipolar Radiofrequency Technology in Stand-alone Persistent Atrial Fibrillation.

    Science.gov (United States)

    Rosati, Fabrizio; Muneretto, Claudio; Merati, Elisa; Polvani, Gianluca; Moltrasio, Massimo; Tondo, Claudio; Curnis, Antonio; Cerini, Manuel; Metras, Alexandre; Bisleri, Gianluigi

    Although minimally invasive approaches for surgical treatment of stand-alone atrial fibrillation have gained popularity for the past decade, ablation technology and extensive lesion sets play a major role in the achievement of a successful procedure, especially in presence of persistent and long-standing persistent atrial fibrillation. We evaluated clinical outcomes after totally endoscopic biatrial epicardial ablation of persistent atrial fibrillation with a novel integrated uni-bipolar radiofrequency device. Forty-nine (49) consecutive patients with stand-alone atrial fibrillation underwent right-sided monolateral thoracoscopic surgical ablation with a novel integrated uni-bipolar radiofrequency energy delivery and temperature-controlled technology. Atrial fibrillation was persistent in 13 (26.5%) of 49 and long-standing persistent in 36 (73.5%) of 49 patients. Mean ± SD age was 60.6 ± 10.3 years. Median duration of atrial fibrillation was 74 months. Mean ± SD left atrial diameter was 44.7 ± 4.0 mm. Epicardial en bloc isolation of all pulmonary veins (box lesion) and additional ablation of the right atrial free wall was successfully performed via minimally invasive approach without any intraoperative and postoperative major complications. Intraoperative entrance and exit block was achieved in 77.5% (38/49) and 91.8% (45/49) of patients, respectively. Mean ± SD ablation time was 16.3 ± 4.8 minutes. No intensive care unit stay was required. Postoperative sinus rhythm was achieved in 93.8% (30/32) patients, and no pacemaker implantation was required. At 13 months, 87.7% (43/49) of patients were in sinus rhythm; 71.4% (35/49) were free from antiarrhythmic drugs and 75.5% (37/49) from oral anticoagulation. Integrated uni-bipolar radiofrequency ablation technology showed to be effective for the surgical treatment of atrial fibrillation with a total endoscopic approach. A versapolar suction device with extensive right-left atrial lesion set may further improve

  10. Changes in myocardial fluid filtration are reflected in epicardial lymph pressure

    NARCIS (Netherlands)

    VanTeeffelen, J. W.; Merkus, D.; Vergroesen, I.; Spaan, J. A.

    1997-01-01

    The effect of increased fluid filtration on stopped-flow epicardial lymph pressure (P(lymph)), used as an indicator of myocardial interstitial volume, was investigated in the anesthetized open-chest dog. Histamine infusion resulted in an increased systolic peak in the P(lymph) signal together with

  11. Epicardial adipose tissue volume estimation by postmortem computed tomography of eviscerated hearts

    DEFF Research Database (Denmark)

    Hindsø, Louise; Jakobsen, Lykke S; Jacobsen, Christina

    2017-01-01

    Epicardial adipose tissue (EAT) may play a role in the development of coronary artery disease. The purpose of this study was to evaluate a method based on postmortem computed tomography (PMCT) for the estimation of EAT volume. We PMCT-scanned the eviscerated hearts of 144 deceased individuals, wh...

  12. Epicardial excitation pattern as observed in the isolated revived and perfused fetal human heart

    NARCIS (Netherlands)

    Durrer, D.; Büller, J.; Graaff, P.; Lo, G.I.; Meijler, F.L.

    1961-01-01

    The resuscitated fetal human heart can be used as an experimental tooI for the investigation of the excitatory process in the human heart. During perfusion the configuration of the epicardial electrocardiograms does not change appreciably. For accurate recording permitting a detailed analysis, the

  13. Primary PCI: time to change focus from epicardial reperfusion towards protection of the microvasculature

    NARCIS (Netherlands)

    van Lavieren, Martijn A.; van de Hoef, Tim P.; Piek, Jan J.

    2014-01-01

    Myocardial tissue perfusion remains compromised in 30-40% of patients with ST-segment elevation myocardial infarction (STEMI) despite restored epicardial patency after primary percutaneous coronary intervention (pPCI). This phenomenon is attributed to microvascular dysfunction secondary to numerous

  14. Inappropriate shock and battery switching to "End of Life" in a patient with biventricular ICD during magnetic resonance imaging.

    Science.gov (United States)

    Atar, İlyas; Bal, Uğur; Ertan, Çağatay; Özin, Bülent; Müderrisoğlu, Haldun

    2016-01-01

    Presence of a cardiac pacemaker or implantable cardioverter defibrillator (ICD) is a relative contraindication to magnetic resonance imaging (MRI). Biventricular ICDs are often used in the treatment of advanced heart failure; however, reports on experience with biventricular ICDs are lacking in the literature. In this case report, we describe a pacemaker-dependent patient with a biventricular ICD on whom an MRI of the lumbar spine was performed without having realized the presence of the ICD.

  15. New Heart Failure Treatment Capability for Remote Environments

    Science.gov (United States)

    2013-06-01

    valve in a cycle manner. Control of the absolute pressure, rate of actuation and resistance in the 19 drive lines were the manner in which...Hegde SS, Lowe JE. Sensing Lead Insulation Fractures Following Implantable Cardioverter-Defibrillator Placement. ASAIO Journal 1993;39:M711-M714...14:45-46,1985. Anstadt MP, Galbraith TA, Murray KD, Howanitz EP, Myerowitz PD: Bridge to Cardiac Transplantation Using Prosthetic Biventricular

  16. A case of appropriate inappropriate device therapy: Hyperkalemia-induced ventricular oversensing

    OpenAIRE

    Oudit, Gavin Y; Cameron, Doug; Harris, Louise

    2008-01-01

    The present case describes a patient who received inappropriate, but potentially life-saving, therapy from her implantable cardioverter defibrillator (ICD) in the setting of acute hyperkalemia (plasma potassium concentration = 8 mM). Hyperkalemia was associated with the development of a slow sinusoidal ventricular tachycardia, at a rate of 100 beats/min to 125 beats/min (610 ms to 480 ms) in a patient who is pacemaker-dependent. There was associated fractionation of the ICD electrogram and T ...

  17. A Rare Diabetic Autonomic Neuropathy: Carotid Sinus Hypersensitivity

    Directory of Open Access Journals (Sweden)

    Ahmet Kaya

    2016-03-01

    Full Text Available Carotid sinus hypersensitivity is a common cause of fainting and falls in the elderly, and can be diagnosed by carotid sinus massage. We present a 67-year-old diabetic man who was admitted with hyperglycemia. During thyroid examination, clouding of consciousness occurred with unilateral palpation. Asystole was documented for 4.8 seconds and suspected for 7 seconds upon carotid sinus massage. A cardioverter defibrillator was implanted. Carotid sinus hypersensitivity should be kept in mind when examining diabetic patients.

  18. A benefit-risk assessment of class III antiarrhythmic agents

    DEFF Research Database (Denmark)

    Elming, Hanne; Brendorp, Bente; Pehrson, Steen

    2004-01-01

    The prevalence of arrhythmia in the population is increasing as more people survive for longer with cardiovascular disease. It was once thought that antiarrhythmic therapy could save life, however, it is now evident that antiarrhythmic therapy should be administrated with the purpose of symptomat......, and reducing the need for implantable cardioverter defibrillator shock/antitachycardia therapy, since no class III antiarrhythmic agents have proven survival benefit. The risks discussed mainly focus on pro-arrhythmia as torsade de pointes ventricular tachycardia....

  19. A Psychological Factor Affecting a Cardiac Condition in a Psychotherapist

    OpenAIRE

    R Waxman; K Khorasani; A Lenny; S Bhalerao

    2009-01-01

    It has been established that intense emotions can affect the development and course of cardiac arrhythmias. This study sought to convey that a lack of expression of emotion can also have an effect on arrhythmias. A psychotherapist with Idiopathic Ventricular Fibrillation and an Implantable Cardioverter Defibrillator measured his rate of Premature Ventricular Contractions using a Holter monitor during three separate six-week periods and in three domains: A) work days vs. off days, B) a 27 hour...

  20. An On-Time Power-Aware Scheduling Scheme for Medical Sensor SoC-Based WBAN Systems

    OpenAIRE

    Hwang, Tae-Ho; Kim, Dong-Sun; Kim, Jung-Guk

    2012-01-01

    The focus of many leading technologies in the field of medical sensor systems is on low power consumption and robust data transmission. For example, the implantable cardioverter-defibrillator (ICD), which is used to maintain the heart in a healthy state, requires a reliable wireless communication scheme with an extremely low duty-cycle, high bit rate, and energy-efficient media access protocols. Because such devices must be sustained for over 5 years without access to battery replacement, the...

  1. Association between endothelial dysfunction, epicardial fat and subclinical atherosclerosis during menopause.

    Science.gov (United States)

    Cabrera-Rego, Julio Oscar; Navarro-Despaigne, Daisy; Staroushik-Morel, Liudmila; Díaz-Reyes, Karel; Lima-Martínez, Marcos M; Iacobellis, Gianluca

    Menopausal transition is critical for the development of early, subclinical vascular damage. Multiple factors, such as atherosclerosis, increased epicardial fat, and endothelial dysfunction can play a role. Hence, the objective of this study was the comparison of epicardial adipose tissue and carotid intima media thickness in order to establish the best predictor of carotid stiffness in middle-aged women with endothelial dysfunction. A total of 43 healthy women aged 40-59 years old with endothelial dysfunction previously demonstrated by flow mediated dilation were recruited to have anthropometric, biochemical, hormonal and ultrasound determinations of carotid intima media thickness and epicardial fat thickness. Carotid arterial stiffness parameters (local pulse wave velocity [4.7±0.7 vs 4.8±0.5 vs 5.6±0.5m/s, respectively, p<0.001], pressure strain elastic modulus [55.2±13.4 vs 59.2±11.8 vs 81.9±15.6kPa, respectively, p<0.001], arterial stiffness index β [4.4±1.4 vs 5.0±1.1 vs 6.4±1.3, respectively, p<0.001]) and epicardial fat thickness (2.98±1.4 vs 3.28±1.9 vs 4.70±1.0mm, respectively, p=0.007) showed a significant and proportional increase in the group of late post-menopausal women when compared to early post-menopausal and pre-menopausal groups, respectively. Among body fat markers, epicardial fat was the strongest predictor of local pulse wave velocity, independent of age. In menopausal women with endothelial dysfunction, menopausal transition is associated with increased carotid arterial stiffness and epicardial fat thickness, independent of age. Ultrasound measured epicardial fat was a better independent predictor of arterial stiffness than carotid intima media thickness in these women. Copyright © 2017 Sociedad Española de Arteriosclerosis. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. The evaluation and management of electrical storm.

    Science.gov (United States)

    Eifling, Michael; Razavi, Mehdi; Massumi, Ali

    2011-01-01

    Electrical storm is an increasingly common and life-threatening syndrome that is defined by 3 or more sustained episodes of ventricular tachycardia, ventricular fibrillation, or appropriate shocks from an implantable cardioverter-defibrillator within 24 hours. The clinical presentation can be dramatic. Electrical storm can manifest itself during acute myocardial infarction and in patients who have structural heart disease, an implantable cardioverter-defibrillator, or an inherited arrhythmic syndrome. The presence or absence of structural heart disease and the electrocardiographic morphology of the presenting arrhythmia can provide important diagnostic clues into the mechanism of electrical storm. Electrical storm typically has a poor outcome.The effective management of electrical storm requires an understanding of arrhythmia mechanisms, therapeutic options, device programming, and indications for radiofrequency catheter ablation. Initial management involves determining and correcting the underlying ischemia, electrolyte imbalances, or other causative factors. Amiodarone and β-blockers, especially propranolol, effectively resolve arrhythmias in most patients. Nonpharmacologic treatment, including radiofrequency ablation, can control electrical storm in drug-refractory patients. Patients who have implantable cardioverter-defibrillators can present with multiple shocks and may require drug therapy and device reprogramming. After the acute phase of electrical storm, the treatment focus should shift toward maximizing heart-failure therapy, performing revascularization, and preventing subsequent ventricular arrhythmias. Herein, we present an organized approach for effectively evaluating and managing electrical storm.

  3. Catheter-based high-intensity ultrasound for epicardial ablation of the left ventricle: device design and in vivo feasiblity

    Science.gov (United States)

    Salgaonkar, Vasant A.; Nazer, Babak; Jones, Peter D.; Tanaka, Yasuaki; Martin, Alastair; Ng, Bennett; Duggirala, Srikant; Diederich, Chris J.; Gerstenfeld, Edward P.

    2015-03-01

    The development and in vivo testing of a high-intensity ultrasound thermal ablation catheter for epicardial ablation of the left ventricle (LV) is presented. Scar tissue can occur in the mid-myocardial and epicardial space in patients with nonischemic cardiomyopathy and lead to ventricular tachycardia. Current ablation technology uses radiofrequency energy, which is limited epicardially by the presence of coronary vessels, phrenic nerves, and fat. Ultrasound energy can be precisely directed to deliver targeted deep epicardial ablation while sparing intervening epicardial nerve and vessels. The proof-of-concept ultrasound applicators were designed for sub-xyphoid access to the pericardial space through a steerable 14-Fr sheath. The catheter consists of two rectangular planar transducers, for therapy (6.4 MHz) and imaging (5 MHz), mounted at the tip of a 3.5-mm flexible nylon catheter coupled and encapsulated within a custom-shaped balloon for cooling. Thermal lesions were created in the LV in a swine (n = 10) model in vivo. The ultrasound applicator was positioned fluoroscopically. Its orientation and contact with the LV were verified using A-mode imaging and a radio-opaque marker. Ablations employed 60-s exposures at 15 - 30 W (electrical power). Histology indicated thermal coagulation and ablative lesions penetrating 8 - 12 mm into the left ventricle on lateral and anterior walls and along the left anterior descending artery. The transducer design enabled successful sparing from the epicardial surface to 2 - 4 mm of intervening ventricle tissue and epicardial fat. The feasibility of targeted epicardial ablation with catheter-based ultrasound was demonstrated.

  4. Quantification of the Arrhythmogenic Effects of Spontaneous Atrial Extrasystole Using High-Resolution Epicardial Mapping.

    Science.gov (United States)

    Teuwen, Christophe P; Kik, Charles; van der Does, Lisette J M E; Lanters, Eva A H; Knops, Paul; Mouws, Elisabeth M J P; Bogers, Ad J J C; de Groot, Natasja M S

    2018-01-01

    Atrial extrasystoles (AES) can initiate atrial fibrillation. However, the impact of spontaneous AES on intra-atrial conduction is unknown. The aims of this study were to examine conduction disorders provoked by AES and to correlate these conduction differences with patient characteristics, mapping locations, and type of AES. High-resolution epicardial mapping (electrodes N=128 or N=192; interelectrode distance, 2 mm) of the entire atrial surface was performed in patients (N=164; 69.5% male; age 67.2±10.5 years) undergoing open-chest cardiac surgery. AES were classified as premature, aberrant, or prematurely aberrant. Conduction delay and conduction block were quantified during sinus rhythm and AES and subsequently compared. Median incidence of conduction delay and conduction block during sinus rhythm was 1.2% (interquartile, 0%-2.3%) and 0.4% (interquartile, 0%-2.1%). In comparison, the median incidence of conduction delay and conduction block during 339 AES was respectively 2.8% (interquartile, 1.3%-4.6%) and 2.2% (interquartile, 0.3%-5.1%) and differed between the types of AES (prematurely aberrant>aberrant>premature). The degree of prematurity was not associated with a higher incidence of conduction disorders ( P >0.05). In contrast, a higher degree of aberrancy was associated with a higher incidence of conduction disorders; AES emerging as epicardial breakthrough provoked most conduction disorders ( P ≥0.002). AES caused most conduction disorders in patients with diabetes mellitus and left atrial dilatation ( P <0.05). Intraoperative high-resolution epicardial mapping showed that conduction disorders are mainly provoked by prematurely aberrant AES, particularly in patients with left atrial dilation and diabetes mellitus or emerging as epicardial breakthrough. © 2017 American Heart Association, Inc.

  5. Epicardial fat volume is correlated with coronary lesion and its severity

    OpenAIRE

    Bo, Xiaohong; Ma, Likun; Fan, Jili; Jiang, Zhe; Zhou, Yuansong; Zhang, Lei; Li, Wanjun

    2015-01-01

    Objective: To evaluate the correlation of epicardial adipose tissue volume (EATV) with the coronary artery lesion and its severity. Methods: Inpatients with suspicious stable angina of coronary heart lesion were recruited. For patients with coronary artery lesions in CTA, further coronary angiography (CAG) was performed to evaluate the coronary artery lesion. Gensini scoring system was employed to assess the severity of coronary artery lesions. Results: Patients were classified as coronary he...

  6. Association between increased epicardial adipose tissue volume and coronary plaque composition

    OpenAIRE

    Yamashita, Kennosuke; Yamamoto, Myong Hwa; Ebara, Seitarou; Okabe, Toshitaka; Saito, Shigeo; Hoshimoto, Koichi; Yakushiji, Tadayuki; Isomura, Naoei; Araki, Hiroshi; Obara, Chiaki; Ochiai, Masahiko

    2013-01-01

    To assess the relationship between epicardial adipose tissue volume (EATV) and plaque vulnerability in significant coronary stenosis using a 40-MHz intravascular ultrasound (IVUS) imaging system (iMap-IVUS), we analyzed 130 consecutive patients with coronary stenosis who underwent dual-source computed tomography (CT) and cardiac catheterization. Culprit lesions were imaged by iMap-IVUS before stenting. The iMAP-IVUS system classified coronary plaque components as fibrous, lipid, necrotic, or ...

  7. Epicardial phrenic nerve displacement during catheter ablation of atrial and ventricular arrhythmias: procedural experience and outcomes.

    Science.gov (United States)

    Kumar, Saurabh; Barbhaiya, Chirag R; Baldinger, Samuel H; Koplan, Bruce A; Maytin, Melanie; Epstein, Laurence M; John, Roy M; Michaud, Gregory F; Tedrow, Usha B; Stevenson, William G

    2015-08-01

    Arrhythmia origin in close proximity to the phrenic nerve (PN) can hinder successful catheter ablation. We describe our approach with epicardial PN displacement in such instances. PN displacement via percutaneous pericardial access was attempted in 13 patients (age 49±16 years, 9 females) with either atrial tachycardia (6 patients) or atrial fibrillation triggered from a superior vena cava focus (1 patient) adjacent to the right PN or epicardial ventricular tachycardia origin adjacent to the left PN (6 patients). An epicardially placed steerable sheath/4 mm-catheter combination (5 patients) or a vascular or an esophageal balloon (8 patients) was ultimately successful. Balloon placement was often difficult requiring manipulation via a steerable sheath. In 2 ventricular tachycardia cases, absence of PN capture was achieved only once the balloon was directly over the ablation catheter. In 3 atrial tachycardia patients, PN displacement was not possible with a balloon; however, a steerable sheath/catheter combination was ultimately successful. PN displacement allowed acute abolishment of all targeted arrhythmias. No PN injury occurred acutely or in follow up. Two patients developed acute complications (pleuro-pericardial fistula 1 and pericardial bleeding 1). Survival free of target arrhythmia was achieved in all atrial tachycardia patients; however, a nontargeted ventricular tachycardia recurred in 1 patient at a median of 13 months' follow up. Arrhythmias originating in close proximity to the PN can be targeted successfully with PN displacement with an epicardially placed steerable sheath/catheter combination, or balloon, but this strategy can be difficult to implement. Better tools for phrenic nerve protection are desirable. © 2015 American Heart Association, Inc.

  8. Epicardial shock-wave therapy improves ventricular function in a porcine model of ischaemic heart disease.

    Science.gov (United States)

    Holfeld, Johannes; Zimpfer, Daniel; Albrecht-Schgoer, Karin; Stojadinovic, Alexander; Paulus, Patrick; Dumfarth, Julia; Thomas, Anita; Lobenwein, Daniela; Tepeköylü, Can; Rosenhek, Raphael; Schaden, Wolfgang; Kirchmair, Rudolf; Aharinejad, Seyedhossein; Grimm, Michael

    2016-12-01

    Previously we have shown that epicardial shock-wave therapy improves left ventricular ejection fraction (LVEF) in a rat model of myocardial infarction. In the present experiments we aimed to address the safety and efficacy of epicardial shock-wave therapy in a preclinical large animal model and to further evaluate mechanisms of action of this novel therapy. Four weeks after left anterior descending (LAD) artery ligation in pigs, the animals underwent re-thoracotomy with (shock-wave group, n = 6) or without (control group, n = 5) epicardial shock waves (300 impulses at 0.38 mJ/mm 2 ) applied to the infarcted anterior wall. Efficacy endpoints were improvement of LVEF and induction of angiogenesis 6 weeks after shock-wave therapy. Safety endpoints were haemodynamic stability during treatment and myocardial damage. Four weeks after LAD ligation, LVEF decreased in both the shock-wave (43 ± 3%, p wave animals 6 weeks after treatment (62 ± 9%, p = 0.006); no improvement was observed in controls (41 ± 4%, p = 0.36), yielding a significant difference. Quantitative histology revealed significant angiogenesis 6 weeks after treatment (controls 2 ± 0.4 arterioles/high-power field vs treatment group 9 ± 3; p = 0.004). No acute or chronic adverse effects were observed. As a potential mechanism of action in vitro experiments showed stimulation of VEGF receptors after shock-wave treatment in human coronary artery endothelial cells. Epicardial shock-wave treatment in a large animal model of ischaemic heart failure exerted a positive effect on LVEF improvement and did not show any adverse effects. Angiogenesis was induced by stimulation of VEGF receptors. Copyright © 2014 John Wiley & Sons, Ltd. Copyright © 2014 John Wiley & Sons, Ltd.

  9. Epicardial fat and atrial fibrillation: current evidence, potential mechanisms, clinical implications, and future directions.

    Science.gov (United States)

    Wong, Christopher X; Ganesan, Anand N; Selvanayagam, Joseph B

    2017-05-01

    Obesity is increasingly recognized as a major modifiable determinant of atrial fibrillation (AF). Although body mass index and other clinical measures are useful indications of general adiposity, much recent interest has focused on epicardial fat, a distinct adipose tissue depot that can be readily assessed using non-invasive imaging techniques. A growing body of data from epidemiological and clinical studies has demonstrated that epicardial fat is consistently associated with the presence, severity, and recurrence of AF across a range of clinical settings. Evidence from basic science and translational studies has also suggested that arrhythmogenic mechanisms may involve adipocyte infiltration, pro-fibrotic, and pro-inflammatory paracrine effects, oxidative stress, and other pathways. Despite these advances, however, significant uncertainty exists and many questions remain unanswered. In this article, we review our present understanding of epicardial fat, including its classification and quantification, existing evidence implicating its role in AF, potential mechanisms, implications for clinicians, and future directions for research. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  10. Spectral analysis of epicardial 60-lead electrograms in dogs with 4-week-old myocardial infarction.

    Science.gov (United States)

    Hosoya, Y; Ikeda, K; Komatsu, T; Yamaki, M; Kubota, I

    2001-01-01

    There were few studies on the spectral analysis of multiple-lead epicardial electrograms in chronic myocardial infarction. Spectral analysis of multi-lead epicardial electrograms was performed in 6 sham-operated dogs (N group) and 8 dogs with 4-week-old myocardial infarction (MI group). Four weeks after the ligation of left anterior descending coronary artery, fast Fourier transform was performed on 60-lead epicardial electrograms, and then inverse transform was performed on 5 frequency ranges from 0 to 250 Hz. From the QRS onset to QRS offset, the time integration of unsigned value of reconstructed waveform was calculated and displayed as AQRS maps. On 0-25 Hz AQRS map, there was no significant difference between the 2 groups. In the frequency ranges of 25-250 Hz, MI group had significantly smaller AQRS values than N group solely in the infarct zone. It was shown that high frequency potentials (25-250 Hz) within QRS complex were reduced in the infarct zone.

  11. Surgical treatment of Wolff-Parkinson-White syndrome: epicardial approach without the use of cardiopulmonary bypass.

    Science.gov (United States)

    Graffigna, A; Pagani, F; Vigano, M

    1993-03-01

    Epicardial dissection without the use of cardiopulmonary bypass (CPB) was performed in 88 patients (56 males and 32 females, mean age 31.9 years). With intraoperative epicardial mapping, 101 accessory pathways were detected, with multiple pathways in 11 patients. CPB was avoided in all but one patient due to frequent onset of atrial fibrillation with rapid ventricular rate. Surgical ablation was successful in 86 patients (97.6%). Three patients required multiple surgical procedures because of persistence of conduction along a component of the original pathway. All but two patients were discharged without antiarrhythmic medication; these two patients were given quinidine therapy because of atrial fibrillation, but had normal early and late electrophysiological studies. Surgical ablation of Kent bundles by the epicardial approach for the treatment of Wolff-Parkinson-White syndrome can be achieved without the use of CPB. Optimal and steady exposure of the area are mandatory for the procedure, and dissection is eased by avoidance of heparin required for CPB.

  12. Role of high-resolution image integration to visualize left phrenic nerve and coronary arteries during epicardial ventricular tachycardia ablation.

    Science.gov (United States)

    Yamashita, Seigo; Sacher, Frédéric; Mahida, Saagar; Berte, Benjamin; Lim, Han S; Komatsu, Yuki; Amraoui, Sana; Denis, Arnaud; Derval, Nicolas; Laurent, François; Montaudon, Michel; Hocini, Mélèze; Haïssaguerre, Michel; Jaïs, Pierre; Cochet, Hubert

    2015-04-01

    Epicardial ventricular tachycardia (VT) ablation is associated with risks of coronary artery (CA) and phrenic nerve (PN) injury. We investigated the role of multidetector computed tomography in visualizing CA and PN during VT ablation. Ninety-five consecutive patients (86 men; age, 57 ± 15) with VT underwent cardiac multidetector computed tomography. The PN detection rate and anatomic variability were analyzed. In 49 patients undergoing epicardial mapping, real-time multidetector computed tomographic integration was used to display CAs/PN locations in 3-dimensional mapping systems. Elimination of local abnormal ventricular activities (LAVAs) was used as ablation end point. The distribution of CAs/PN with respect to LAVA was analyzed and compared between VT etiologies. Multidetector computed tomography detected PN in 81 patients (85%). Epicardial LAVAs were observed in 44 of 49 patients (15 ischemic cardiomyopathy, 15 nonischemic cardiomyopathy, and 14 arrhythmogenic right ventricular cardiomyopathy) with a mean of 35 ± 37 LAVA points/patient. LAVAs were located within 1 cm from CAs and PN in 35 (80%) and 18 (37%) patients, respectively. The prevalence of LAVA adjacent to CAs was higher in nonischemic cardiomyopathy and arrhythmogenic right ventricular cardiomyopathy than in ischemic cardiomyopathy (100% versus 86% versus 53%; P < 0.01). The prevalence of LAVAs adjacent to PN was higher in nonischemic cardiomyopathy than in ischemic cardiomyopathy (93% versus 27%; P < 0.001). Epicardial ablation was performed in 37 patients (76%). Epicardial LAVAs could not be eliminated because of the proximity to CAs or PN in 8 patients (18%). The epicardial electrophysiological VT substrate is often close to CAs and PN in patients with nonischemic cardiomyopathy. High-resolution image integration is potentially useful to minimize risks of PN and CA injury during epicardial VT ablation. © 2015 American Heart Association, Inc.

  13. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  14. Ventricular tachycardia in ischemic cardiomyopathy; a combined endo-epicardial ablation as the first procedure versus a stepwise approach (EPILOGUE) - study protocol for a randomized controlled trial

    NARCIS (Netherlands)

    A.A. Hendriks (Astrid A.); M. Khan (M.); L. Geller (Laszlo); A. Kardos (Attila); L.J. de Vries (Lennart); S-C. Yap (Sing-Chien); S.A. Wijchers (Sip A.); D.A.M.J. Theuns (Dominic); T. Szili-Torok (Tamas)

    2015-01-01

    textabstractBackground: The role of epicardial substrate ablation of ventricular tachycardia (VT) as a first-line approach in patients with ischemic heart disease is not clearly defined. Epicardial ablation as a first-line option is standard for patients with nonischemic dilated cardiomyopathy and

  15. Relationship Between Neck Circumference and Epicardial Fat Thickness in a Healthy Male Population.

    Science.gov (United States)

    Küçük, Uğur; Küçük, Hilal Olgun; Cüce, Ferhat; Balta, Sevket

    2016-09-01

    Epicardial fat is an upper body visceral fat depot that may play a significant role in the development of adverse metabolic and cardiovascular risk profiles. There is a significant direct relationship between the amount of epicardial fat and general body adiposity (body mass index, BMI), but data regarding subcutaneous adiposity is limited. We conducted a study to determine the association between neck circumference and epicardial fat thickness in healthy young male individuals, and assess their individual correlations with general body adiposity and cardiometabolic risk factors. One hundred consecutive male patients aged 18 years or older with no known major medical conditions were included in the study. All participants underwent detailed physical examination including measurement of blood pressure, weight, height, waist/hip ratio, and neck circumference. Blood was collected to determine fasting glucose and lipid parameters. A standard echocardiographic examination was performed with additional epicardial fat thickness determination. Among 100 study participants, neck circumference correlated significantly with weight, waist circumference, BMI, blood glucose, serum total cholesterol, low-density (LDL)-cholesterol, and triglycerides levels. No significant correlation was found between neck circumference and high-density lipoprotein (HDL)-cholesterol levels. Neck circumference correlated moderately and positively with echocardiographic epicardial fat thickness. Among patients with low cardiometabolic risk, increased neck circumference was associated with increased epicardial fat thickness. A gordura epicárdica é um depósito de gordura visceral na parte superior do organismo que pode desempenhar um papel importante no desenvolvimento de perfis cardiovasculares e metabólicos adversos. Há uma relação direta significativa entre a quantidade de gordura epicárdica e a adiposidade corporal geral (índice de massa corporal, IMC), mas dados sobre a adiposidade

  16. Posterior Coronary Vein as the Substrate for an Epicardial Accessory Pathway

    Directory of Open Access Journals (Sweden)

    Laura Cipoletta, MD

    2013-07-01

    Full Text Available Catheter ablation of Wolff-Parkinson-White syndrome is associated with up to 5% of failure. Coronary sinus (CS abnormalities or connections between CS myocardial coat and left ventricular epicardium are associated with posteroseptal and left posterior accessory pathways (AP. A 41-year-old patient with WPW syndrome was referred to our hospital after three unsuccessful ablations. The 12-lead ECG suggested a left posteroseptal AP. CT imaging and electro-anatomic mapping showed a relationship between AP electrical course and CS posterior branch. This finding supports the hypothesis CSAPs lie in the myocardial coat around CS and represent an extensive connection between atrial and ventricular epicardial surface.

  17. Epicardial Breakthrough Waves During Sinus Rhythm: Depiction of the Arrhythmogenic Substrate?

    Science.gov (United States)

    Mouws, Elisabeth M J P; Lanters, Eva A H; Teuwen, Christophe P; van der Does, Lisette J M E; Kik, Charles; Knops, Paul; Bekkers, Jos A; Bogers, Ad J J C; de Groot, Natasja M S

    2017-09-01

    Epicardial breakthrough waves (EBW) during atrial fibrillation are important elements of the arrhythmogenic substrate and result from endo-epicardial asynchrony, which also occurs to some degree during sinus rhythm (SR). We examined the incidence and characteristics of EBW during SR and its possible value in the detection of the arrhythmogenic substrate associated with atrial fibrillation. Intraoperative epicardial mapping (interelectrode distances 2 mm) of the right atrium, Bachmann's bundle, the left atrioventricular groove, and the pulmonary vein area was performed during SR in 381 patients (289 male, 67±10 years) with ischemic or valvular heart disease. EBW were referred to as sinus node breakthrough waves if they were the earliest right atrial activated site. A total of 218 EBW and 57 sinus node breakthrough waves were observed in 168 patients (44%). EBW mostly occurred at right atrium (N=105, 48%) and left atrioventricular groove (N=67, 31%), followed by Bachmann's bundle (N=27, 12%) and pulmonary vein area (N=19, 9%; P <0.001). EBW occurred most often in ischemic heart disease patients (N=114, 49%) compared with (ischemic and) valvular heart disease patients (N=26, 17%; P <0.001). EBW electrograms most often consisted of double and fractionated potentials (N=137, 63%). In case of single potentials, an R wave was observed in 88% (N=71) of EBW, as opposed to 21% of sinus node breakthrough waves (N=5; P <0.001). Fractionated EBW potentials were more often observed at the right atrium and Bachmann's bundle ( P <0.001). During SR, EBW are present in over a third of patients, particularly in thicker parts of the atrial wall. Features of SR EBW indicate that muscular connections between endo- and epicardium underlie EBW and that a slight degree of endo-epicardial asynchrony required for EBW to occur is already present in some areas during SR. Hence, an anatomic substrate is present, which may enhance the occurrence of EBW during atrial fibrillation, thereby

  18. Relation of epicardial adipose tissue with arterial compliance and stiffness in patients with hypertension.

    Science.gov (United States)

    Korkmaz, Levent; Cirakoglu, Omer Faruk; Ağaç, Mustafa Tarik; Erkan, Hakan; Korkmaz, Ayca Ata; Acar, Zeydin; Kul, Selim; Hatem, Engin; Çelik, Şükrü

    2014-09-01

    The main aim of the present study was to investigate the association between epicardial adipose tissue (EAT) and arterial function in patients with asymptomatic hypertension. Patients with hypertension (n = 155) were enrolled consecutively. Patients with decreased arterial compliance (AC) and increased cardioankle vascular index (CAVI) had higher EAT values compared with those with normal AC and CAVI (6.23 ± 1.67 vs 4.91 ± 1.40, P arterial function in patients with asymptomatic hypertension. The link between EAT and arterial stiffness deserves further investigation. © The Author(s) 2013.

  19. Impact of irrigation flow rate and intrapericardial fluid on cooled-tip epicardial radiofrequency ablation.

    Science.gov (United States)

    Aryana, Arash; O'Neill, Padraig Gearoid; Pujara, Deep K; Singh, Steve K; Bowers, Mark R; Allen, Shelley L; d'Avila, André

    2016-08-01

    The optimal irrigation flow rate (IFR) during epicardial radiofrequency (RF) ablation has not been established. This study specifically examined the impact of IFR and intrapericardial fluid (IPF) accumulation during epicardial RF ablation. Altogether, 452 ex vivo RF applications (10 g for 60 seconds) delivered to the epicardial surface of bovine myocardium using 3 open-irrigated ablation catheters (ThermoCool SmartTouch, ThermoCool SmartTouch-SF, and FlexAbility) and 50 in vivo RF applications delivered (ThermoCool SmartTouch-SF) in 4 healthy adult swine in the presence or absence of IPF were examined. Ex vivo, RF was delivered at low (≤3 mL/min), reduced (5-7 mL/min), and high (≥10 mL/min) IFRs using intermediate (25-35 W) and high (35-45 W) power. In vivo, applications were delivered (at 9.3 ± 2.2 g for 60 seconds at 39 W) using reduced (5 mL/min) and high (15 mL/min) IFRs. Ex vivo, surface lesion diameter inversely correlated with IFR, whereas maximum lesion diameter and depth did not differ. While steam pops occurred more frequently at low IFR using high power (ThermoCool SmartTouch and ThermoCool SmartTouch-SF), tissue disruption was rare and did not vary with IFR. In vivo, charring/steam pop was not detected. Although there were no discernible differences in lesion size with IFR, surface lesion diameter, maximum diameter, depth, and volume were all smaller in the presence of IPF at both IFRs. Cooled-tip epicardial RF ablation created using reduced IFRs (5-7 mL/min) yields lesion sizes similar to those created using high IFRs (≥10 mL/min) without an increase in steam pop/tissue disruption, whereas the presence of IPF significantly reduces the lesion size. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  20. Epicardial adipose tissue as a predictor of coronary artery disease in asymptomatic subjects.

    Science.gov (United States)

    Bachar, Gil N; Dicker, Dror; Kornowski, Ran; Atar, Eli

    2012-08-15

    This study sought to elucidate the relation between epicardial adipose tissue (EAT) thickness measured by multidetector computed tomography and presence of coronary artery atherosclerosis. Recent studies have suggested that fat disposition in visceral organs and epicardial tissue could serve as a predictor of coronary artery disease (CAD). The sample included 190 asymptomatic subjects with ≥ 1 cardiovascular risk factor who were referred for cardiac computed tomographic angiography. Body mass index, blood pressure, fasting glucose level, and lipid profile were measured. Multidetector computed tomographic results were analyzed for atherosclerosis burden, calcium Agatston score, and EAT thickness: mean EAT values were 3.54 ± 1.59 mm in patients with atherosclerosis and 1.85 ± 1.28 mm in patients without atherosclerosis (p 50% diameter) coronary artery stenosis. There was a significant difference in EAT values between patients with and without metabolic syndrome (2.58 ± 1.63 vs 2.04 ± 1.46 mm, p 400 and <400 (3.38 ± 1.58 vs 2.02 ± 1.42 mm, p <0.0001). In conclusion, asymptomatic patients with CAD have significantly more EAT than patients without CAD. An EAT thickness of 2.4 mm is the optimal cutoff for prediction of presence of significant CAD. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Increased bioactive lipids content in human subcutaneous and epicardial fat tissue correlates with insulin resistance.

    Science.gov (United States)

    Błachnio-Zabielska, Agnieszka U; Baranowski, Marcin; Hirnle, Tomasz; Zabielski, Piotr; Lewczuk, Anna; Dmitruk, Iwona; Górski, Jan

    2012-12-01

    Obesity is a risk factor for metabolic diseases. Intramuscular lipid accumulation of ceramides, diacylglycerols, and long chain acyl-CoA is responsible for the induction of insulin resistance. These lipids are probably implicated in obesity-associated insulin resistance not only in skeletal muscle but also in fat tissue. Only few data are available about ceramide content in human subcutaneous adipose tissue. However, there are no data on DAG and LCACoA content in adipose tissue. The aim of our study was to measure the lipids content in human SAT and epicardial adipose tissue we sought to determine the bioactive lipids content by LC/MS/MS in fat tissue from lean non-diabetic, obese non-diabetic, and obese diabetic subjects and test whether the lipids correlate with HOMA-IR. We found, that total content of measured lipids was markedly higher in OND and OD subjects in both types of fat tissue (for all p lipids content is greater in subcutaneous and epicardial fat tissue and the particular lipids content positively correlates with HOMA-IR.

  2. Blood plasma lipidomic signature of epicardial fat in healthy obese women.

    Science.gov (United States)

    Scherer, Max; Montoliu, Ivan; Qanadli, Salah D; Collino, Sebastiano; Rezzi, Serge; Kussmann, Martin; Giusti, Vittorio; Martin, François-Pierre J

    2015-01-01

    A lipidomic approach was employed in a clinically well-defined cohort of healthy obese women to explore blood lipidome phenotype ascribed to body fat deposition, with emphasis on epicardial adipose tissue (EAT). The present investigation delivered a lipidomics signature of epicardial adiposity under healthy clinical conditions using a cohort of 40 obese females (age: 25-45 years, BMI: 28-40 kg/m(2) ) not showing any metabolic disease traits. Lipidomics analysis of blood plasma was employed in combination with in vivo quantitation of mediastinal fat depots by computerized tomography. All cardiac fat depots correlated to indicators of hepatic dysfunctions (ALAT and ASAT), which describe physiological connections between hepatic and cardiac steatosis. Plasma lipidomics encompassed overall levels of lipid classes, fatty acid profiles, and individual lipid species. EAT and visceral fat associated with diacylglycerols (DAG), triglycerides, and distinct phospholipid and sphingolipid species. A pattern of DAG and phosphoglycerols was specific to EAT. Human blood plasma lipidomics appears to be a promising clinical and potentially diagnostic readout for patient stratification and monitoring. Association of blood lipidomics signature to regio-specific mediastinal and visceral adiposity under healthy clinical conditions may help provide more biological insights into obese patient stratification for cardiovascular disease risks. © 2014 The Obesity Society.

  3. Prognostic value of epicardial fat volume measurements by computed tomography: a systematic review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Spearman, James V.; Krazinski, Aleksander W. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Renker, Matthias [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Giessen University, Department of Internal Medicine I, Cardiology/Angiology, Giessen (Germany); Schoepf, U.J. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Herbert, Teri L. [Medical University of South Carolina, Department of Library Science and Informatics, Charleston, SC (United States); De Cecco, Carlo N. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' Sapienza' - Polo Pontino, Department of Radiological Sciences, Oncology and Pathology, Latina (Italy); Nietert, Paul J. [Medical University of South Carolina, Department of Public Health Sciences, Charleston, SC (United States); Meinel, Felix G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Ludwig-Maximilians-University Hospital, Institute for Clinical Radiology, Munich (Germany)

    2015-11-15

    To perform a systematic review of the growing body of literature evaluating the prognostic value of epicardial fat volume (EFV) quantified by cross-sectional imaging. Two independent reviewers performed systematic searches on both PubMed and Scopus using search terms developed with a medical librarian. Peer-reviewed articles were selected based on the inclusion of outcome data, utilization of epicardial fat volume and sufficient reporting for analysis. A total of 411 studies were evaluated with nine studies meeting the inclusion criteria. In all, the studies evaluated 10,252 patients. All nine studies were based on CT measurements. Seven studies evaluated the prognostic value of EFV unadjusted for calcium score, and six of these studies found a significant association between EFV and clinical outcomes. Seven studies evaluated the incremental value of EFV beyond calcium scoring, and six of these studies found a significant association. The majority of studies suggest that EFV quantification is significantly associated with clinical outcomes and provides incremental prognostic value over coronary artery calcium scoring. Future research should use a binary cutoff of 125 mL for evaluation of EFV to provide consistency with other research. (orig.)

  4. Is epicardial adipose tissue, another measure of central obesity, correlated with erectile dysfunction?

    Directory of Open Access Journals (Sweden)

    Chih-Wei Tsao

    2016-01-01

    Full Text Available Background: This study investigated the correlation between epicardial adipose tissue (EAT, a measure of central obesity, and sexual function in males with vasculogenic erectile dysfunction (ED. Materials and Methods: The study was a cross-sectional study of selected males with ED aged <75 years who attended the Urology Outpatient Department of Tri-Service General Hospital. Sixty subjects were included in the study, which employed biochemical data, anthropometric indexes, echocardiography, and questionnaires. Biochemical lipid profiles and associated inflammation markers were recorded. The anthropometric indexes included general and central obesity and bioelectrical impedance analysis. Echocardiography results were assessed by a single experienced cardiologist and included epicardial and pericardial fat thickness measurements. Sexual function was evaluated using the International Index of Erectile Function-5 (IIEF-5 score. Results: According to the analysis of variance and multivariate logistic regression, only the erectile hardness score (EHS was statistically positively correlated with the IIEF-5 score. All other anthropometric indexes and echocardiography parameters, including EAT thickness, pericardial adipose tissue thickness, and ejection fraction (EF, were not significantly associated with sexual function. Conclusions: Only EHS was statistically associated with sexual function in the male subjects with ED. The anthropometric indexes and EAT thickness, a measure of central obesity, were not significantly correlated with sexual function in the male patients with ED.

  5. Communication between integrin receptors facilitates epicardial cell adhesion and matrix organization.

    Science.gov (United States)

    Pae, So Hyun; Dokic, Danijela; Dettman, Robert W

    2008-04-01

    Formation of the epicardium requires interactions between alpha(4)beta(1) integrin, and the extracellular matrix. We investigated the role of other integrins expressed by epicardial cells. We detected transcripts for alpha(5), alpha(8), alpha(v), beta(1), beta(3), and beta(5) integrins in the chick proepicardial organ (PE). We demonstrate that alpha(5)beta(1), alpha(8)beta(1), and alpha(v)beta(3) integrins are expressed by chick epicardial mesothelial cells (EMCs). Migration of EMCs in vitro was reduced by RGD-containing peptides. Using adenoviruses expressing an antisense to chick alpha(4) (AdGFPalpha4AS), full-length (Adhalpha4V5), and C-terminal deleted alpha(4) (Adhalpha4DeltaCV5), we found that EMCs were less able to adhere to vitronectin and fibronectin(120) indicating that alpha(4)beta(1) plays a role in regulating EMC adhesion to ligands of alpha(5)beta(1), alpha(8)beta(1), and alpha(v)beta(3). In Adhalpha4DeltaCV5-infected EMCs, alpha(5)beta(1) was diminished in fibrillar adhesions and new FN matrix assembly was abnormal. We propose that cooperation between alpha(4)beta(1) and RGD integrins is important for EMC adhesion and subepicardial matrix formation. (c) 2008 Wiley-Liss, Inc.

  6. Association between increased epicardial adipose tissue volume and coronary plaque composition.

    Science.gov (United States)

    Yamashita, Kennosuke; Yamamoto, Myong Hwa; Ebara, Seitarou; Okabe, Toshitaka; Saito, Shigeo; Hoshimoto, Koichi; Yakushiji, Tadayuki; Isomura, Naoei; Araki, Hiroshi; Obara, Chiaki; Ochiai, Masahiko

    2014-09-01

    To assess the relationship between epicardial adipose tissue volume (EATV) and plaque vulnerability in significant coronary stenosis using a 40-MHz intravascular ultrasound (IVUS) imaging system (iMap-IVUS), we analyzed 130 consecutive patients with coronary stenosis who underwent dual-source computed tomography (CT) and cardiac catheterization. Culprit lesions were imaged by iMap-IVUS before stenting. The iMAP-IVUS system classified coronary plaque components as fibrous, lipid, necrotic, or calcified tissue, based on the radiofrequency spectrum. Epicardial adipose tissue was measured as the tissue ranging from -190 to -30 Hounsfield units. EATV, calculated as the sum of the fat areas on short-axis images, was 85.0 ± 34.0 cm(3). There was a positive correlation between EATV and the percentage of necrotic plaque tissue (R (2) = 0.34, P EATV and the percentage of fibrous tissue (R (2) = 0.24, P EATV (β = 0.14, P = 0.02) were independently associated with the percentage of necrotic plaque tissue. An increase in EATV was associated with the development of coronary atherosclerosis and, potentially, with the most dangerous type of plaque.

  7. Impact of ischemic and valvular heart disease on atrial excitation : A high-resolution epicardial mapping study

    NARCIS (Netherlands)

    E.M.J.P. Mouws (Elisabeth); E. Lanters (Eva); C. Teuwen (Christophe); L. van der Does (Lisette); C. Kik (Charles); S.P. Knops (Simon); A. Yaksh (Ameeta); J.A. Bekkers (Jos); A.J.J.C. Bogers (Ad); N.M.S. de Groot (Natasja)

    2018-01-01

    markdownabstractBackground--The influence of underlying heart disease or presence of atrial fibrillation (AF) on atrial excitation during sinus rhythm (SR) is unknown. We investigated atrial activation patterns and total activation times of the entire atrial epicardial surface during SR in patients

  8. Unipolar Endocardial Voltage Mapping in the Right Ventricle: Optimal Cutoff Values Correcting for Computed Tomography-Derived Epicardial Fat Thickness and Their Clinical Value for Substrate Delineation.

    Science.gov (United States)

    Venlet, Jeroen; Piers, Sebastiaan R D; Kapel, Gijsbert F L; de Riva, Marta; Pauli, Philippe F G; van der Geest, Rob J; Zeppenfeld, Katja

    2017-08-01

    Low endocardial unipolar voltage (UV) at sites with normal bipolar voltage (BV) may indicate epicardial scar. Currently applied UV cutoff values are based on studies that lacked epicardial fat information. This study aimed to define endocardial UV cutoff values using computed tomography-derived fat information and to analyze their clinical value for right ventricular substrate delineation. Thirty-three patients (50±14 years; 79% men) underwent combined endocardial-epicardial right ventricular electroanatomical mapping and ablation of right ventricular scar-related ventricular tachycardia with computed tomographic image integration, including computed tomography-derived fat thickness. Of 6889 endocardial-epicardial mapping point pairs, 547 (8%) pairs with distance 1.50 mV, the optimal endocardial UV cutoff for identification of epicardial BV the curve, 0.75; sensitivity, 60%; specificity, 79%) and cutoff for identification of abnormal epicardial electrogram was 3.7 mV (area under the curve, 0.88; sensitivity, 100%; specificity, 67%). The majority of abnormal electrograms (130 of 151) were associated with transmural scar. Eighty-six percent of abnormal epicardial electrograms had corresponding endocardial sites with BV the remaining could be identified by corresponding low endocardial UV right ventricular scar, an endocardial UV cutoff value of 3.9 mV is more accurate than previously reported cutoff values. Although the majority of epicardial abnormal electrograms are associated with transmural scar with low endocardial BV, the additional use of endocardial UV at normal BV sites improves the diagnostic accuracy resulting in identification of all epicardial abnormal electrograms at sites with <1.0 mm fat. © 2017 American Heart Association, Inc.

  9. Epicardial mapping of ventricular fibrillation over the posterior descending artery and left posterior papillary muscle of the swine heart.

    Science.gov (United States)

    Nielsen, Thomas D; Huang, Jian; Rogers, Jack M; Killingsworth, Cheryl R; Ideker, Raymond E

    2009-01-01

    Recent studies suggest that during ventricular fibrillation (VF) epicardial vessels may be a site of conduction block and the posterior papillary muscle (PPM) in the left ventricle (LV) may be the location of a "mother rotor." The goal of this study was to obtain evidence to support or refute these possibilities. Epicardial activation over the posterior LV and right ventricle (RV) was mapped during the first 20 s of electrically induced VF in six open-chest pigs with a 504 electrode plaque covering a 20 cm(2) area centered over the posterior descending artery (PDA). The locations of epicardial breakthrough as well as reentry clustered in time and space during VF. Spatially, reentry occurred significantly more frequently over the LV than the RV in all 48 episodes, and breakthrough clustered near the PPM (p < 0.001). Significant temporal clustering occurred in 79% of breakthrough episodes and 100% of reentry episodes. These temporal clusters occurred at different times so that there was significantly less breakthrough when reentry was present (p < 0.0001). Conduction block occurred significantly more frequently near the PDA than elsewhere. The PDA is a site of epicardial block which may contribute to VF maintenance. Epicardial breakthrough clusters near the PPM. Reentry also clusters in space but at a separate site. The fact that breakthrough and reentry cluster at different locations and at different times supports the possibility of a drifting filament at the PPM so that at times reentry is present on the surface but at other times the reentrant wavefront breaks through to the epicardium.

  10. Influence of technical parameters on epicardial fat volume quantification at cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Bucher, Andreas M. [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Frankfurt (Germany); Joseph Schoepf, U., E-mail: schoepf@musc.edu [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Krazinski, Aleksander W.; Silverman, Justin; Spearman, James V. [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); De Cecco, Carlo N. [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncology and Pathology, University of Rome “Sapienza” – Polo Pontino, Latina (Italy); Meinel, Felix G. [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich (Germany); Vogl, Thomas J. [Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Frankfurt (Germany); Geyer, Lucas L. [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich (Germany)

    2015-06-15

    Highlights: • Upper threshold levels and contrast enhancement influence epicardial fat volumetry. • Cardiac cycle does not significantly influence epicardial fat volumetry. • Adjustments of upper threshold can lead to comparable volumetry results. - Abstract: Objectives: To systematically analyze the influence of technical parameters on quantification of epicardial fat volume (EATV) at cardiac CT. Methods: 153 routine cardiac CT data sets were analyzed using three-dimensional pericardial border delineation. Three image series were reconstructed per patient: (a) CTA{sub D}: coronary CT angiography (CTA), diastolic phase; (b) CTA{sub S}: coronary CTA, systolic phase; (c) CaSc{sub D}: non-contrast CT, diastolic phase. EATV was calculated using three different upper thresholds (−15HU, −30HU, −45HU). Repeated measures ANOVA, Spearman's rho, and Bland Altman plots were used. Results: Mean EATV differed between all three image series at a −30HU threshold (CTA{sub D} 87.2 ± 38.5 ml, CTA{sub S} 90.9 ± 37.7 ml, CaSc{sub D} 130.7 ± 49.5 ml, P < 0.001). EATV of diastolic and systolic CTA reconstructions did not differ significantly (P = 0.225). Mean EATV for contrast enhanced CTA at a −15HU threshold (CTA{sub D15} 102.4 ± 43.6 ml, CTA{sub S15} 105.3 ± 42.3 ml) could be approximated most closely by non-contrast CT at −45HU threshold (CaSc{sub D45} 105.3 ± 40.8 ml). The correlation was excellent: CTA{sub S15}–CTA{sub D15}, rho = 0.943; CTA{sub D15}–CaSc{sub D45}, rho = 0.905; CTA{sub S15}–CaSc{sub D45}, rho = 0.924; each P < 0.001). Bias values from Bland Altman Analysis were: CTA{sub S15}–CTA{sub D15}, 4.9%; CTA{sub D15}–CaSc{sub D45}, −4.3%; CTA{sub S15}–CaSc{sub D45}, 0.6%. Conclusions: Measured EATV can differ substantially between contrast enhanced and non-contrast CT studies, which can be reconciled by threshold modification. Heart cycle phase does not significantly influence EATV measurements.

  11. Influence of technical parameters on epicardial fat volume quantification at cardiac CT

    International Nuclear Information System (INIS)

    Bucher, Andreas M.; Joseph Schoepf, U.; Krazinski, Aleksander W.; Silverman, Justin; Spearman, James V.; De Cecco, Carlo N.; Meinel, Felix G.; Vogl, Thomas J.; Geyer, Lucas L.

    2015-01-01

    Highlights: • Upper threshold levels and contrast enhancement influence epicardial fat volumetry. • Cardiac cycle does not significantly influence epicardial fat volumetry. • Adjustments of upper threshold can lead to comparable volumetry results. - Abstract: Objectives: To systematically analyze the influence of technical parameters on quantification of epicardial fat volume (EATV) at cardiac CT. Methods: 153 routine cardiac CT data sets were analyzed using three-dimensional pericardial border delineation. Three image series were reconstructed per patient: (a) CTA D : coronary CT angiography (CTA), diastolic phase; (b) CTA S : coronary CTA, systolic phase; (c) CaSc D : non-contrast CT, diastolic phase. EATV was calculated using three different upper thresholds (−15HU, −30HU, −45HU). Repeated measures ANOVA, Spearman's rho, and Bland Altman plots were used. Results: Mean EATV differed between all three image series at a −30HU threshold (CTA D 87.2 ± 38.5 ml, CTA S 90.9 ± 37.7 ml, CaSc D 130.7 ± 49.5 ml, P < 0.001). EATV of diastolic and systolic CTA reconstructions did not differ significantly (P = 0.225). Mean EATV for contrast enhanced CTA at a −15HU threshold (CTA D15 102.4 ± 43.6 ml, CTA S15 105.3 ± 42.3 ml) could be approximated most closely by non-contrast CT at −45HU threshold (CaSc D45 105.3 ± 40.8 ml). The correlation was excellent: CTA S15 –CTA D15 , rho = 0.943; CTA D15 –CaSc D45 , rho = 0.905; CTA S15 –CaSc D45 , rho = 0.924; each P < 0.001). Bias values from Bland Altman Analysis were: CTA S15 –CTA D15 , 4.9%; CTA D15 –CaSc D45 , −4.3%; CTA S15 –CaSc D45 , 0.6%. Conclusions: Measured EATV can differ substantially between contrast enhanced and non-contrast CT studies, which can be reconciled by threshold modification. Heart cycle phase does not significantly influence EATV measurements

  12. Troponin elevation in patients with various tachycardias and normal epicardial coronaries

    Directory of Open Access Journals (Sweden)

    Yousuf Kanjwal

    2008-08-01

    Full Text Available Troponin elevation is usually synonymous with acute coronary syndrome (ACS. Although sensitive for ACS, the elevation of serum troponin, in the absence of clinical evidence of ischemia, should prompt a search for other etiologies of myocardial necrosis. In fact, elevated values of troponin are correlated with myocardial necrosis even though it does not discriminate the mechanism involved. We report a series of seven patients (age range 18-67 years, who presented with complaints of chest discomfort and were found to have regular supraventricular tachycardia (5 patients and one patient each with atrial fibrillation and ventricular tachycardia. All these patients had elevated troponin I and underwent coronary angiography that revealed normal epicardial coronary arteries. This is first case series in which all patients underwent coronary angiography and none of the patients was hemodynamically unstable at the time of presentation. Patients with elevated troponin due to conditions other than ACS can receive inappropriate and delayed definitive diagnosis and treatment.

  13. Atrioesophageal Fistula after Minimally Invasive Video-Assisted Epicardial Ablation for Lone Atrial Fibrillation.

    Science.gov (United States)

    Kik, Charles; van Valen, Richard; Mokhles, Mostafa M; Bekkers, Jos A; Bogers, Ad J J C

    2017-09-01

    Minimally invasive video-assisted epicardial beating heart ablation for lone atrial fibrillation claims to be safe and effective. We, however, report on three patients with an atrioesophageal fistula after this procedure. The exact pathogenesis of this complication is unknown. All patients presented around 6 weeks after surgery with either fever or neurological deficits. Diagnosis can be made by computed tomography scan. We advocate an aggressive surgical approach with closure of the atrial defect on cardiopulmonary bypass and closure and reinforcement of the esophagus with an intercostal muscle flap in a single-stage surgery. Some caution as to the low-risk character of this procedure seems to be realistic. Georg Thieme Verlag KG Stuttgart · New York.

  14. Cochlear Implants

    Science.gov (United States)

    ... implant, including: • How long a person has been deaf, •The number of surviving auditory nerve fibers, and • ... Implant, Severe Sensoryneurial Hearing Loss Get Involved Professional Development Practice Management ENT Careers Marketplace Privacy Policy Terms ...

  15. Epicardial adipose tissue and cardiometabolic risk factors in overweight and obese children and adolescents.

    Science.gov (United States)

    Schusterova, I; Leenen, F H H; Jurko, A; Sabol, F; Takacova, J

    2014-02-01

    What is already known about this subject The prevalence of childhood obesity has increased markedly in the past 2 decades. Abdominal fat is a better predictor of risk than body mass index. Waist circumference (WC) as a measure of abdominal fat has limited sensitivity and specificity. What this study adds Epicardial adipose tissue (EAT) as measured by echocardiography represents a simple and reliable marker of visceral adiposity. In children, both body mass index and EAT show a similar or better correlation with markers of cardiometabolic risk than does waist circumference. Epicardial adipose tissue (EAT) is the visceral fat deposit around the heart and is commonly increased in obese subjects. EAT is related to cardiometabolic risk factors and non-alcoholic fatty liver disease (NAFLD) in adults, but this relationship is not well known in children. Echocardiographic assessment of EAT and its association with cardiometabolic risk factors in overweight and obese children. In 25 (mean age 13.0 ± 2.3) overweight and obese subjects and 24 lean controls, blood pressure (BP), WC, fasting plasma glucose and insulin, lipids, uric acid and hepatic enzymes were measured. EAT thickness was measured by transthoracic echocardiography. In overweight and obese subjects, EAT was significantly higher compared to normal weight children. Overweight and obese children had significantly higher body mass index (BMI), WC, BP, triglycerides (TAG), low-density lipoprotein and total cholesterol, hepatic enzymes alanine aminotransferase (ALT) and γ-glutamyl transferase, and lower high-density lipoprotein cholesterol (HDL-C). EAT correlated significantly with BP, TAG, uric acid, HDL-C, apoprotein B and ALT. Correlation coefficients were similar or better than for WC, but similar or lower than for BMI. EAT thickness in children is associated with an unfavourable cardiometabolic risk profile including biochemical signs of NAFLD and hyperuricaemia, but is not a stronger indicator than BMI.

  16. Triiodothyronine promotes the proliferation of epicardial progenitor cells through the MAPK/ERK pathway

    International Nuclear Information System (INIS)

    Deng, Song-Bai; Jing, Xiao-Dong; Wei, Xiao-ming; Du, Jian-Lin; Liu, Ya-Jie; Qin, Qin; She, Qiang

    2017-01-01

    Thyroid hormone has important functions in the development and physiological function of the heart. The aim of this study was to determine whether 3,5,3′-Triiodothyronine (T3) can promote the proliferation of epicardial progenitor cells (EPCs) and to investigate the potential underlying mechanism. Our results showed that T3 significantly promoted the proliferation of EPCs in a concentration- and time-dependent manner. The thyroid hormone nuclear receptor inhibitor bisphenol A (100 μmol/L) did not affect T3's ability to induce proliferation. Further studies showed that the mRNA expression levels of mitogen-activated protein kinase 1 (MAPK1), MAPK3, and Ki67 in EPCs in the T3 group (10 nmol/L) increased 2.9-, 3-, and 4.1-fold, respectively, compared with those in the control group (P < 0.05). In addition, the mRNA expression of the cell cycle protein cyclin D1 in the T3 group increased approximately 2-fold compared with the control group (P < 0.05), and there were more EPCs in the S phase of the cell cycle (20.6% vs. 12.0%, P < 0.05). The mitogen-activated protein kinase/extracellular signal-regulated kinase (MAPK/ERK) signaling pathway inhibitor U0126 (10 μmol/L) significantly inhibited the ability of T3 to promote the proliferation of EPCs and to alter cell cycle progression. This study suggested that T3 significantly promotes the proliferation of EPCs, and this effect may be achieved through activation of the MAPK/ERK signaling pathway. - Highlights: • Epicardial progenitor cells were successfully cultured from E12.5 mice. • Thyroid hormone T3 significantly promoted the proliferation of EPCs. • This biological effect may be mediated via activation of the MAPK/ERK pathway.

  17. Association of chemerin mRNA expression in human epicardial adipose tissue with coronary atherosclerosis

    Directory of Open Access Journals (Sweden)

    Wang Linjie

    2011-10-01

    Full Text Available Abstract Background Growing evidence suggests that epicardial adipose tissue (EAT may play a key role in the pathogenesis and development of coronary artery disease (CAD by producing several inflammatory adipokines. Chemerin, a novel adipokine, has been reported to be involved in regulating immune responses and glucolipid metabolism. Given these properties, chemerin may provide an interesting link between obesity, inflammation and atherosclerosis. In this study, we sought to determine the relationship of chemerin expression in EAT and the severity of coronary atherosclerosis in Han Chinese patients. Methods Serums and adipose tissue biopsies (epicardial and thoracic subcutaneous were obtained from CAD (n = 37 and NCAD (n = 16 patients undergoing elective cardiac surgery. Gensini score was used to assess the severity of CAD. Serum levels of chemerin, adiponectin and insulin were measured by ELISA. Chemerin protein expression in adipose tissue was detected by immunohistochemistry. The mRNA levels of chemerin, chemR23, adiponectin and TNF-alpha in adipose tissue were detected by RT-PCR. Results We found that EAT of CAD group showed significantly higher levels of chemerin and TNF-alpha mRNA, and significantly lower level of adiponectin mRNA than that of NCAD patients. In CAD group, significantly higher levels of chemerin mRNA and protein were observed in EAT than in paired subcutaneous adipose tissue (SAT, whereas such significant difference was not found in NCAD group. Chemerin mRNA expression in EAT was positively correlated with Gensini score (r = 0.365, P P P P P P P > 0.05. Conclusions The expressions of chemerin mRNA and protein are significantly higher in EAT from patients with CAD in Han Chinese patients. Furthermore, the severity of coronary atherosclerosis is positive correlated with the level of chemerin mRNA in EAT rather than its circulating level.

  18. Epicardial adipose tissue radiodensity is independently related to coronary atherosclerosis. A multidetector computed tomography study

    International Nuclear Information System (INIS)

    Pracon, R.; Kruk, M.; Kepka, C.

    2011-01-01

    Preliminary research indicates that epicardial adipose tissue (EAT) may display both anti- and proatherosclerotic properties. Because the varying radiodensities of selected human tissues assessed by multidetector computed tomography (MDCT) has been shown to reflect differences in biological characteristics, the present study investigated the hypothesis that the proatherosclerotic properties of EAT may be linked to its radiodensity. The study included 164 consecutive patients (82 females, mean age 58.8±11.1 years) with suspected coronary artery disease (CAD) undergoing MDCT coronary angiography. Coronary atherosclerosis was defined as: CAD (id est (ie), presence of at least 1 coronary stenosis ≥50%) and coronary artery calcium (CAC) determined by Agatston score. EAT radiodensity was assessed by MDCT and averaged -81.00±4.64 HU (Hounsfield unit (HU) scale). Mean CAC score was 96.0±220.0. Patients with CAD (n=36) showed higher EAT radiodensity than patients without CAD (-78.99±4.12 vs. -81.57±4.64 HU, P<0.01). In the multivariable model, only EAT radiodensity and age were independently associated with CAD (odds ratio (OR) 1.15, 95%confidence interval (CI) 1.04-1.28; OR 1.08, 95%CI 1.04-1.12; respectively). EAT radiodensity also correlated with CAC score (r=0.23, P<0.01). EAT radiodensity (P<0.001), age (P<0.001), sex (P=0.03), and past smoking (P<0.01) were independent correlates of CAC in the multivariable linear regression model. Increased EAT radiodensity is independently associated with coronary atherosclerosis, which may reflect the unfavorable, proatherosclerotic metabolic properties of more radiodense epicardial fat. (author)

  19. Epicardial adipose tissue thickness and NGAL levels in women with polycystic ovary syndrome.

    Science.gov (United States)

    Sahin, Serap Baydur; Cure, Medine Cumhur; Ugurlu, Yavuz; Ergul, Elif; Gur, Emine Uslu; Alyildiz, Nese; Bostan, Mehmet

    2014-02-16

    Polycystic ovary syndrome (PCOS) is associated with an increased cardiovascular disease (CVD) risk and early atherosclerosis. Epicardial adipose tissue thickness (EATT) is clinically related to subclinical atherosclerosis. In the present study, considering the major role of neutrophil gelatinase-associated lipocalin (NGAL) which is an acute phase protein rapidly releasing upon inflammation and tissue injury, we aimed to evaluate NGAL levels and EATT in PCOS patients and assess their relationship with cardiometabolic factors. 64 patients with PCOS and 50 age- and body mass index-matched healthy controls were included in the study. We evaluated anthropometric, hormonal and metabolic parameters. EATT was measured by echocardiography above the free wall of the right ventricle. Serum NGAL and high-sensitive C- reactive protein (hsCRP) levels were measured by ELISA. Mean EATT was 0,38 +/-0,16 mm in the PCOS group and 0,34 +/-0,36 mm in the control group (p = 0,144). In the obese PCOS group (n = 44) EAT was thicker compared to the obese control group (n = 41) (p = 0.026). Mean NGAL levels of the patients with PCOS were 101,98 +/-21,53 pg/ml, while mean NGAL levels were 107,40 +/-26,44 pg/ml in the control group (p = 0,228). We found a significant positive correlation between EATT and age, BMI, waist circumference, fasting insulin, HOMA-IR, triglyceride and hsCRP levels in PCOS group. Thickness of the epicardial adipose tissue can be used to follow the risk of CVD development in obese PCOS cases. However serum NGAL levels do not differ in patients with PCOS and control group.

  20. Screening for heart transplantation and left ventricular assist system

    DEFF Research Database (Denmark)

    Lund, Lars H; Trochu, Jean-Noel; Meyns, Bart

    2018-01-01

    BACKGROUND: Heart transplantation (HTx) and implantable left ventricular assist systems (LVAS) improve outcomes in advanced heart failure but may be underutilized. We hypothesized that screening can identify appropriate candidates. METHODS AND RESULTS: The ScrEEning for advanced Heart Failure...... treatment (SEE-HF) study was a multicentre prospective study screening patients with existing cardiac resynchronization therapy (CRT) and/or implantable cardioverter-defibrillator (ICD) for ejection fraction ≤40% and New York Heart Association (NYHA) class III-IV, and subsequently for guideline-based HTx...

  1. Successful resuscitation of a patient with electrical storm.

    Science.gov (United States)

    Moulik, P K; Attar, M N; Rose, E L; Khaleeli, A A

    2003-05-01

    A 41 year old woman with type 2 diabetes, hypertension, and hyperlipidaemia but no known heart disease received 130 DC shocks for repeated cardiac arrests due to ventricular tachyarrhythmias over 48 hours. She was stabilised by intravenous amiodarone and had a defibrillator implanted. Serial ECGs did not change, but raised troponin I confirmed myocardial infarction as the underlying cause. Electrical storm is an uncommon and dramatic but usually treatable syndrome of recurrent ventricular arrhythmias. Frequent precipitants of electrical storm include recent worsening heart failure, hypokalaemia, hypomagnesaemia and myocardial ischaemia. Amiodarone is the antiarrhythmic agent of choice and implantable cardioverter defibrillator improves long term outcome.

  2. Successful transjugular extraction of a lead in front of the anterior scalene muscle by using snare technique

    Directory of Open Access Journals (Sweden)

    Ayako Okada, MD

    2015-08-01

    Full Text Available The incidence of cardiovascular implantable electronic device infection is increasing. We report a case of and successful device removal in a 79-year-old man with implantable cardioverter-defibrillator infection. Right phrenic nerve paralysis was evident on chest radiography. The lead was in front of the anterior scalene muscle, close to the left phrenic nerve. Therefore, extraction carried a risk of bilateral phrenic nerve paralysis. The lead was successfully extracted from the right internal jugular vein by using the snare technique. No complications occurred, and the extraction was successful.

  3. Reconstruction of the Terminal of an Abandoned Fractured Unipolar Coronary Sinus Lead: a Feasible Solution to Restore Effective Cardiac Resynchronization Therapy

    Directory of Open Access Journals (Sweden)

    Armando Gardini, MD

    2013-05-01

    Full Text Available Complications related to coronary sinus lead are not infrequent in recipients of cardiac resynchronization devices. We describe the case of a patient with a biventricular implantable cardioverter defibrillator with persistent phrenic nerve stimulation, previous coronary sinus lead fracture, and severe left subclavian vein stenosis. The reimplantation of a new coronary sinus lead on the left side, ipsilateral to the original implant, was unsuccessful. In order to avoid more complex and risky procedures, we performed the repair of the fractured abandoned lead with the reconstruction of the unipolar lead terminal. Effective biventricular pacing was obtained with satisfactory electrical parameters and it was maintained at twelve months follow-up.

  4. International External Validation Study of the 2014 European Society of Cardiology Guidelines on Sudden Cardiac Death Prevention in Hypertrophic Cardiomyopathy (EVIDENCE-HCM).

    Science.gov (United States)

    O'Mahony, Constantinos; Jichi, Fatima; Ommen, Steve R; Christiaans, Imke; Arbustini, Eloisa; Garcia-Pavia, Pablo; Cecchi, Franco; Olivotto, Iacopo; Kitaoka, Hiroaki; Gotsman, Israel; Carr-White, Gerald; Mogensen, Jens; Antoniades, Loizos; Mohiddin, Saidi A; Maurer, Mathew S; Tang, Hak Chiaw; Geske, Jeffrey B; Siontis, Konstantinos C; Mahmoud, Karim D; Vermeer, Alexa; Wilde, Arthur; Favalli, Valentina; Guttmann, Oliver P; Gallego-Delgado, Maria; Dominguez, Fernando; Tanini, Ilaria; Kubo, Toru; Keren, Andre; Bueser, Teofila; Waters, Sarah; Issa, Issa F; Malcolmson, James; Burns, Tom; Sekhri, Neha; Hoeger, Christopher W; Omar, Rumana Z; Elliott, Perry M

    2018-03-06

    Identification of people with hypertrophic cardiomyopathy (HCM) who are at risk of sudden cardiac death (SCD) and require a prophylactic implantable cardioverter defibrillator is challenging. In 2014, the European Society of Cardiology proposed a new risk stratification method based on a risk prediction model (HCM Risk-SCD) that estimates the 5-year risk of SCD. The aim was to externally validate the 2014 European Society of Cardiology recommendations in a geographically diverse cohort of patients recruited from the United States, Europe, the Middle East, and Asia. This was an observational, retrospective, longitudinal cohort study. The cohort consisted of 3703 patients. Seventy three (2%) patients reached the SCD end point within 5 years of follow-up (5-year incidence, 2.4% [95% confidence interval {CI}, 1.9-3.0]). The validation study revealed a calibration slope of 1.02 (95% CI, 0.93-1.12), C-index of 0.70 (95% CI, 0.68-0.72), and D-statistic of 1.17 (95% CI, 1.05-1.29). In a complete case analysis (n= 2147; 44 SCD end points at 5 years), patients with a predicted 5-year risk of <4% (n=1524; 71%) had an observed 5-year SCD incidence of 1.4% (95% CI, 0.8-2.2); patients with a predicted risk of ≥6% (n=297; 14%) had an observed SCD incidence of 8.9% (95% CI, 5.96-13.1) at 5 years. For every 13 (297/23) implantable cardioverter defibrillator implantations in patients with an estimated 5-year SCD risk ≥6%, 1 patient can potentially be saved from SCD. This study confirms that the HCM Risk-SCD model provides accurate prognostic information that can be used to target implantable cardioverter defibrillator therapy in patients at the highest risk of SCD. © 2017 American Heart Association, Inc.

  5. Ventricular filling slows epicardial conduction and increases action potential duration in an optical mapping study of the isolated rabbit heart

    Science.gov (United States)

    Sung, Derrick; Mills, Robert W.; Schettler, Jan; Narayan, Sanjiv M.; Omens, Jeffrey H.; McCulloch, Andrew D.; McCullough, A. D. (Principal Investigator)

    2003-01-01

    INTRODUCTION: Mechanical stimulation can induce electrophysiologic changes in cardiac myocytes, but how mechanoelectric feedback in the intact heart affects action potential propagation remains unclear. METHODS AND RESULTS: Changes in action potential propagation and repolarization with increased left ventricular end-diastolic pressure from 0 to 30 mmHg were investigated using optical mapping in isolated perfused rabbit hearts. With respect to 0 mmHg, epicardial strain at 30 mmHg in the anterior left ventricle averaged 0.040 +/- 0.004 in the muscle fiber direction and 0.032 +/- 0.006 in the cross-fiber direction. An increase in ventricular loading increased average epicardial activation time by 25%+/- 3% (P action potential duration at 20% repolarization (APD20) but did at 80% repolarization (APD80), from 179 +/- 7 msec to 207 +/- 5 msec (P action potential duration by a load-dependent mechanism that may not involve stretch-activated channels.

  6. Novel Percutaneous Epicardial Autonomic Modulation in the Canine for Atrial Fibrillation: Results of an Efficacy and Safety Study

    Science.gov (United States)

    Madhavan, Malini; Venkatachalam, K. L.; Swale, Matthew J.; DeSimone, Christopher V.; Gard, Joseph J.; Johnson, Susan B.; Suddendorf, Scott H.; Mikell, Susan B.; Ladewig, Dorothy J.; Nosbush, Toni Grabinger; Danielsen, Andrew J.; Knudson, Mark; Asirvatham, Samuel J.

    2016-01-01

    Background Endocardial ablation of atrial ganglionated plexi (GP) has been described for treatment of atrial fibrillation (AF). Our objective in this study was to develop percutaneous epicardial GP ablation in a canine model using novel energy sources and catheters. Methods Phase 1: The efficacy of several modalities to ablate the GP was tested in an open chest canine model (n=10). Phase 2: Percutaneous epicardial ablation of GP was done in 6 dogs using the most efficacious modality identified in phase 1 using 2 novel catheters. Results Phase 1: DC in varying doses [blocking (7 -12μA), electroporation (300-500μA), ablation (3000- 7500μA)], radiofrequency ablation (25–50 W), ultrasound (1.5MHz), and alcohol (2-5ml) injection were successful at 0/8, 4/12, 5/7, 3/8, 1/5 and 5/7 GP sites. DC (500–5000μA) along with alcohol irrigation was tested in phase 2. Phase 2: Percutaneous epicardial ablation of the right atrium, oblique sinus, vein of Marshall, and transverse sinus GP was successful in 5/6 dogs. One dog died of ventricular fibrillation (VF) during DC ablation at 5000 μA. Programmed stimulation induced AF in 6 dogs pre-ablation and no atrial arrhythmia in 3, flutter in 1 and AF in 1 post-ablation. Heart rate, blood pressure, effective atrial refractory period and local atrial electrogram amplitude did not change significantly post-ablation. Microscopic examination showed elimination of GP, and minimal injury to atrial myocardium. Conclusion Percutaneous epicardial ablation of GP using direct current and novel catheters is safe and feasible and may be used as an adjunct to pulmonary vein isolation in the treatment of atrial fibrillation in order to minimize additional atrial myocardial ablation. PMID:26854009

  7. Progressive epicardial coronary blood flow reduction fails to produce ST-segment depression at normal heart rates.

    Science.gov (United States)

    de Chantal, Marilyn; Diodati, Jean G; Nasmith, James B; Amyot, Robert; LeBlanc, A Robert; Schampaert, Erick; Pharand, Chantal

    2006-12-01

    ST-segment depression is commonly seen in patients with acute coronary syndromes. Most authors have attributed it to transient reductions in coronary blood flow due to nonocclusive thrombus formation on a disrupted atherosclerotic plaque and dynamic focal vasospasm at the site of coronary artery stenosis. However, ST-segment depression was never reproduced in classic animal models of coronary stenosis without the presence of tachycardia. We hypothesized that ST-segment depression occurring during acute coronary syndromes is not entirely explained by changes in epicardial coronary artery resistance and thus evaluated the effect of a slow, progressive epicardial coronary artery occlusion on the ECG and regional myocardial blood flow in anesthetized pigs. Slow, progressive occlusion over 72 min (SD 27) of the left anterior descending coronary artery in 20 anesthetized pigs led to a 90% decrease in coronary blood flow and the development of ST-segment elevation associated with homogeneous and transmural myocardial blood flow reductions, confirmed by microspheres and myocardial contrast echocardiography. ST-segment depression was not observed in any ECG lead before the development of ST-segment elevation. At normal heart rates, progressive epicardial stenosis of a coronary artery results in myocardial ischemia associated with homogeneous, transmural reduction in regional myocardial blood flow and ST-segment elevation, without preceding ST-segment depression. Thus, in coronary syndromes with ST-segment depression and predominant subendocardial ischemia, factors other than mere increases in epicardial coronary resistance must be invoked to explain the heterogeneous parietal distribution of flow and associated ECG changes.

  8. Association of Epicardial Adipose Tissue and High?Risk Plaque Characteristics: A Systematic Review and Meta?Analysis

    OpenAIRE

    Nerlekar, Nitesh; Brown, Adam J.; Muthalaly, Rahul G.; Talman, Andrew; Hettige, Thushan; Cameron, James D.; Wong, Dennis T. L.

    2017-01-01

    Background Epicardial adipose tissue (EAT) is hypothesized to alter atherosclerotic plaque composition, with potential development of high?risk plaque (HRP). EAT can be measured by volumetric assessment (EAT?v) or linear thickness (EAT?t). We performed a systematic review and random?effects meta?analysis to assess the association of EAT with HRP and whether this association is dependent on the measurement method used. Methods and Results Electronic databases were systematically searched up to...

  9. Relationship between epicardial adipose tissue, coronary artery disease and adiponectin in a Mexican population.

    Science.gov (United States)

    Yañez-Rivera, Teresa G; Baños-Gonzalez, Manuel A; Ble-Castillo, Jorge L; Torres-Hernandez, Manuel E; Torres-Lopez, Jorge E; Borrayo-Sanchez, Gabriela

    2014-09-08

    The amount of epicardial adipose tissue (EAT) around the heart has been identified as an independent predictor of coronary artery disease (CAD), potentially through local release of inflammatory cytokines. Ethnic differences have been observed, but no studies have investigated this relationship in the Mexican population. The objective of the present study was to evaluate whether a relationship exist between EAT thickness assessed via echocardiography with CAD and adiponectin levels in a Mexican population. We studied 153 consecutive patients who underwent coronary angiography and transthoracic echocardiography (TTE). EAT thickness on the free wall of the right ventricle was measured at the end of systole from parasternal long and short axis views of three consecutive cardiac cycles. Coronary angiograms were analyzed for the presence, extent and severity of CAD. Serum adiponectin, lipids, glucose, C-reactive protein and fibrinogen were determined. EAT thickness was greater in patients with CAD than in those without CAD from both parasternal long (5.39 ± 1.75 mm vs 4.00 ± 1.67 mm p<0.0001) and short-axis views (5.23 ± 1.67 vs 4.12 ± 1.77, p=0.001). EAT thickness measured from parasternal long and short-axis showed a statistically significant positive correlation with age (r=0.354, p<0.001; r=0.286, p<0.001 respectively), and waist circumference (r=0.189, p=0.019; r=0.217, p=0.007 respectively). A significant negative correlation between EAT thickness from the parasternal long axis with cholesterol-HDL was observed (r=-0.163, p=0.045). No significant correlation was found between epicardial fat thickness and serum adiponectin or with the severity of CAD. EAT thickness was greater in patients with CAD. However, no correlation was observed with the severity of the disease or with serum adiponectin levels. EAT thickness measured by echocardiography might provide additional information for risk assessment and prediction of CAD.

  10. Epicardial fat volume and aortic stiffness in healthy individuals. A quantitative cardiac magnetic resonance study

    Energy Technology Data Exchange (ETDEWEB)

    Homsi, R.; Thomas, D.; Meier-Schroers, M.; Dabir, D.; Kuetting, D.; Luetkens, J.A.; Marx, C.; Schild, H.H. [Bonn University Hospital (Germany). Radiology; Gieseke, J. [Philips Healthcare, Hamburg (Germany); Sprinkart, A. [Bonn University Hospital (Germany). Radiology; Bochum Univ. (Germany). Inst. of Medical Engineering

    2016-09-15

    To determine epicardial fat volume (EFV) and aortic stiffness (assessed by aortic pulse wave velocity (PWV)) in healthy individuals, and to investigate the relationship of these parameters, and their association with body mass index (BMI) and age. 58 subjects (29 men, mean age 44.7 ± 13.9 years[y]) underwent a CMR exam at 1.5 Tesla. A 2 D velocity-encoded CMR scan was acquired to determine PWV. The EFV was measured based on a 3 D-mDixon sequence. Group comparisons were made between younger (age < 45y; n=30; mean age 33.4 ± 6.6y) and older (> 45y; n=28; 56.7 ± 8.4y) subjects and between subjects with a BMI < 25 kg/m{sup 2} (n=28; BMI 21.9 ± 2.5 kg/m{sup 2}) and a BMI > 25 kg/m{sup 2} (n=30; 28.7 ± 4.0 kg/m{sup 2}). Associations between the determined parameters were assessed by analyses of covariance (ANCOVAs). The mean values of PWV and EFV (normalized to body surface area) were 6.9 ±1.9 m/s and 44.2 ± 25.0 ml/m{sup 2}, respectively. The PWV and EFV were significantly higher in the older group (PWV=7.9 ± 2.0 m/s vs. 6.0 ± 1.2 m/s; EFV=54.7 ml/m{sup 2} vs. 34.5 ml/m{sup 2}; p < 0.01, each), with no significant differences in BMI or sex. In the overweighted group the EFV was significantly higher than in subjects with a BMI < 25kg/m{sup 2} (EFV=56.1 ± 27.1 ml/m{sup 2} vs. 31.5 ± 14.6 ml/m{sup 2}; p < 0.01) but without a significant difference in PWV. ANCOVA revealed a significant correlation between EFV and PWV, also after adjustment for age (p=0.025). An association was found between age and EFV as well as PWV. EFV and PWV were related to each other also after adjustment for age. The metabolic and pro-inflammatory activity found with increased epicardial fat volume may promote the development of atherosclerosis and aortic stiffness. CMR may be valuable for future studies investigating the relationship between EFV and PWV in patients with increased cardiovascular risk.

  11. Hypertrophic Cardiomyopathy in Children, Adolescents, and Young Adults Associated With Low Cardiovascular Mortality With Contemporary Management Strategies.

    Science.gov (United States)

    Maron, Barry J; Rowin, Ethan J; Casey, Susan A; Lesser, John R; Garberich, Ross F; McGriff, Deepa M; Maron, Martin S

    2016-01-05

    Youthful age has been considered the time of greatest risk for patients with hypertrophic cardiomyopathy (HCM), largely because of the possibility of sudden death. The last 2 decades have witnessed more reliable identification of at-risk patients and utilization of implantable cardioverter-defibrillators for prevention of sudden death, and other contemporary treatment options. Whether such management advances have significantly altered the considerable mortality rate for young HCM patients remains unresolved. We studied long-term outcome in 474 consecutive HCM patients between 7 and 29 years of age presenting at 2 referral institutions. Over 7.1±5.1 years of follow-up (6.0 [3.0, 10.0]), 452 patients (95%) survived, with 95% experiencing no or mild symptoms. HCM-related death occurred in 18 patients (3%; 0.54%/y): arrhythmic sudden death (n=12), progressive heart failure and heart transplant complications (n=5), or postoperatively (n=1). In contrast, aborted life-threatening events occurred in 63 other high-risk patients (13%) with implantable cardioverter-defibrillator interventions for ventricular tachyarrhythmias (n=31), resuscitated out-of-hospital cardiac arrest (n=20), or heart transplant for advanced heart failure (n=12), 1.8%/y, 3-fold higher than HCM mortality. Five- and 10-year survival (considering only HCM deaths) was high (97% and 94%, respectively), virtually identical to that reported in middle-aged adult HCM patients (98% and 94%, P=0.23). In a large hospital-based cohort of young HCM patients, representing an age group considered at greatest risk, low mortality rates can be achieved with the application of contemporary cardiovascular treatment strategies, largely because of reliable identification of high-risk patients who benefited from implantable cardioverter-defibrillators for sudden death prevention, thereby creating the opportunity for extended longevity and good quality of life. © 2015 American Heart Association, Inc.

  12. [The role of epicardial fat and obesity parameters in the prediction of coronary heart disease].

    Science.gov (United States)

    Prídavková, Dana; Kantárová, Daniela; Lišková, Renáta; Červeň, Peter; Kovář, František; Mokáň, Marián

    2016-04-01

    To assess the relationship of parameters of obesity in relationship to coronary angiography findings with correlation of epicardial fat (EF) thickness in uppermentioned context. There were 80 patients examined (43 males, 37 postmenopausal females) undergoing elective coronary angiography. We examined the regular obesity parameters - BMI, waist circumference (WC), neck circumference (NC), total body fat (TBF), and visceral fat (VF) using bioimpedance. We assessed the echocardiographically measured EF thickness. We added examination of lipidogram, glycaemia, HOMA-IR (insulin resistance index) and AIP (aterogenic index of plasma). The set was divided into group with coronarographically proved stenosis or stenoses (withCS), and a group without finding of quantifiable stenosis or stenoses (withoutCS). The average thickness of EF in withCS group was 6.3 vs 5.6 mm in group withoutCS (p obesity parameters in assessment of pre-clinical stages of coronary atherosclerosis and prediction of risk of coronary heart disease. In adipose parameters, EF thickness was correlated the most by WC. Risk stratification of coronary artery disease is supplemented by increased HOMA-IR and AIP.

  13. Automated quantification of epicardial adipose tissue using CT angiography: evaluation of a prototype software

    International Nuclear Information System (INIS)

    Spearman, James V.; Silverman, Justin R.; Krazinski, Aleksander W.; Costello, Philip; Meinel, Felix G.; Geyer, Lucas L.; Schoepf, U.J.; Apfaltrer, Paul; Canstein, Christian; De Cecco, Carlo Nicola

    2014-01-01

    This study evaluated the performance of a novel automated software tool for epicardial fat volume (EFV) quantification compared to a standard manual technique at coronary CT angiography (cCTA). cCTA data sets of 70 patients (58.6 ± 12.9 years, 33 men) were retrospectively analysed using two different post-processing software applications. Observer 1 performed a manual single-plane pericardial border definition and EFV M segmentation (manual approach). Two observers used a software program with fully automated 3D pericardial border definition and EFV A calculation (automated approach). EFV and time required for measuring EFV (including software processing time and manual optimization time) for each method were recorded. Intraobserver and interobserver reliability was assessed on the prototype software measurements. T test, Spearman's rho, and Bland-Altman plots were used for statistical analysis. The final EFV A (with manual border optimization) was strongly correlated with the manual axial segmentation measurement (60.9 ± 33.2 mL vs. 65.8 ± 37.0 mL, rho = 0.970, P 0.9). Automated EFV A quantification is an accurate and time-saving method for quantification of EFV compared to established manual axial segmentation methods. (orig.)

  14. Knockdown of Zebrafish Blood Vessel Epicardial Substance Results in Incomplete Retinal Lamination

    Directory of Open Access Journals (Sweden)

    Yu-Ching Wu

    2014-01-01

    Full Text Available Cell polarity during eye development determines the normal retinal lamination and differentiation of photoreceptor cells in the retina. In vertebrates, blood vessel epicardial substance (Bves is known to play an important role in the formation and maintenance of the tight junctions essential for epithelial cell polarity. In the current study, we generated a transgenic zebrafish Bves (zbves promoter-EGFP zebrafish line to investigate the expression pattern of Bves in the retina and to study the role of zbves in retinal lamination. Immunostaining with different specific antibodies from retinal cells and transmission electron microscopy were used to identify the morphological defects in normal and Bves knockdown zebrafish. In normal zebrafish, Bves is located at the apical junctions of embryonic retinal neuroepithelia during retinogenesis; later, it is strongly expressed around inner plexiform layer (IPL and retinal pigment epithelium (RPE. In contrast, a loss of normal retinal lamination and cellular polarity was found with undifferentiated photoreceptor cells in Bves knockdown zebrafish. Herein, our results indicated that disruption of Bves will result in a loss of normal retinal lamination.

  15. Effect of the Epicardial Adipose Tissue Volume on the Prevalence of Paroxysmal and Persistent Atrial Fibrillation.

    Science.gov (United States)

    Oba, Kageyuki; Maeda, Minetaka; Maimaituxun, Gulinu; Yamaguchi, Satoshi; Arasaki, Osamu; Fukuda, Daiju; Yagi, Shusuke; Hirata, Yukina; Nishio, Susumu; Iwase, Takashi; Takao, Shoichiro; Kusunose, Kenya; Yamada, Hirotsugu; Soeki, Takeshi; Wakatsuki, Tetsuzo; Harada, Masafumi; Masuzaki, Hiroaki; Sata, Masataka; Shimabukuro, Michio

    2018-05-25

    Although increasing evidence suggests that epicardial adipose tissue volume (EATV) is associated with atrial fibrillation (AF), it is controversial whether there is a dose-response relationship of increasing EATV along the continuum of AF. We evaluated the effect of the EATV on the prevalence of paroxysmal AF (PAF) and persistent AF (PeAF) and the relationships with cardiac structure and functional remodeling.Methods and Results:Subjects who underwent multidetector computed tomography (MDCT) coronary angiography because of symptoms suggestive of coronary artery disease were divided into sinus rhythm (SR) (n=112), PAF (n=133), and PeAF (n=71) groups. The EATV index (EATV/body surface area, mL/m 2 ) was strongly associated with the prevalence of PAF and PeAF on the model adjusted for known AF risk factors. The effect of the EATV index on the prevalence of PeAF, but not on that of PAF, was modified by the left atrial (LA) dimension, suggesting that extension of the LA dimension is related to EATV expansion in PeAF. The cutoff value of the EATV index for the prevalence was higher in PeAF than in PAF (64 vs. 55 mL/m 2 , PEATV index is associated with the prevalence of PAF and PeAF, and its cutoff values are predictive for PAF and PeAF development independently of other AF risk factors.

  16. Epicardial fat volume is correlated with coronary lesion and its severity.

    Science.gov (United States)

    Bo, Xiaohong; Ma, Likun; Fan, Jili; Jiang, Zhe; Zhou, Yuansong; Zhang, Lei; Li, Wanjun

    2015-01-01

    To evaluate the correlation of epicardial adipose tissue volume (EATV) with the coronary artery lesion and its severity. Inpatients with suspicious stable angina of coronary heart lesion were recruited. For patients with coronary artery lesions in CTA, further coronary angiography (CAG) was performed to evaluate the coronary artery lesion. Gensini scoring system was employed to assess the severity of coronary artery lesions. Patients were classified as coronary heart disease (CHD) group (n = 160). Results showed the mean EATV was 192.57 ± 30.32 cm(3) in CHD group, which was significantly larger than that in control group (138.56 ± 23.18 cm(3); P EATV among patients with different severities of coronary artery stenosis (P EATV (r = 0.285, P = 0.000). The EATV increased with the increase in the number of affected coronary arteries. Multivariate Logistic regression analysis showed EATV was an independent risk factor of CHD after adjusting other confounding factors (OR = 1.023, P = 0.013). EATV is closely related to the severity of coronary artery lesions: the larger the EATV, the more severe the coronary artery lesions. Moreover, EATV is an independent risk factor of CHD.

  17. Ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.

    1986-01-01

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  18. Eccentric apical hypertrophic cardiomyopathy unmasked by multimodality imaging: an uncommon but missed cause of out of hospital cardiac arrest

    Science.gov (United States)

    Towe, Eric; Sharma, Saurabh; Geske, Jeffrey; Ackerman, Michael J

    2015-01-01

    A woman in her late 50s experienced a witnessed, sudden out of hospital cardiac arrest. Initial workup included coronary angiography, transthoracic echocardiogram and a CT scan of the chest to rule out pulmonary embolus. She was subsequently discharged home without an implantable cardioverter defibrillator (ICD) or a life vest. On follow-up at another facility, an ICD was placed and a Holter monitor showed no ventricular ectopy. Further transthoracic echocardiographic images were obtained, which were suggestive of apical hypertrophic cardiomyopathy. A limited transthoracic echocardiogram with contrast was performed, which did not elucidate the hypertrophy. However, eccentric left ventricular apical wall hypertrophy was visualised by a coronary CT scan. PMID:26153133

  19. Heart Failure: From Research to Clinical Practice.

    Science.gov (United States)

    Islam, Md Shahidul

    2018-01-01

    "Heart failure: from research to clinical practice", a collection of selected reviews, which comes out also as a book, covers essentially all important aspects of heart failure, including the pathogenesis, clinical features, biomarkers, imaging techniques, medical treatment and surgical treatments, use of pacemakers and implantable cardioverter defibrillators, and palliative care. The reviews include essential background information, state of the art, critical and in-depth analysis, and directions for future researches for elucidation of the unresolved issues. Everyone interested in heart failure is expected to find this compilation helpful for a deeper understanding of some of the complex issues.

  20. A case of short-coupled premature ventricular beat-induced ventricular fibrillation with early repolarization in the inferolateral leads

    Directory of Open Access Journals (Sweden)

    Hidekazu Kondo, MD

    2015-02-01

    Full Text Available This case report describes a 19-year-old man with early repolarization (ER in the inferolateral leads and a normal QT interval who survived a cardiac arrest that was likely related to polymorphic ventricular tachycardia (VT. Electrocardiograms (ECGs also showed unifocal premature ventricular beats (PVBs with a relatively narrow QRS duration. A Holter ECG documented occasional short-coupled PVBs following non-sustained VTs. Pharmacological stress testing was also performed to assess the effects of anti-arrhythmic drugs on ER (the J wave and PVBs. We performed successful radiofrequency catheter ablation to prevent the recurrence of ventricular fibrillation after cardioverter-defibrillator implantation.

  1. Landiolol suppression of electrical storm of torsades de pointes in patients with congenital long-QT syndrome type 2 and myocardial ischemia

    Directory of Open Access Journals (Sweden)

    Ryota Kitajima, MD

    2017-10-01

    Full Text Available A 76-year-old man who had been diagnosed with long-QT syndrome type 2 had frequent syncopal attacks. The electrocardiogram was monitored, and frequent torsades de pointes (TdP was detected despite administration of conventional medications: oral propranolol, verapamil, intravenous magnesium sulfate, verapamil, and lidocaine. In contrast, 2 μg/kg/min landiolol could completely suppress TdP. Subsequently, an implantable cardioverter defibrillator was placed, and he was diagnosed with silent myocardial ischemia using myocardial perfusion scintigraphy and coronary angiography. This is the first case report wherein landiolol effectively suppressed TdP due to long-QT syndrome with silent myocardial ischemia.

  2. Towards evidence-based emergency medicine: Best BETs from the Manchester Royal Infirmary. BET 2: Is there value in testing troponin levels after ICD discharge?

    Science.gov (United States)

    Targett, Chris; Harris, Tim

    2014-03-01

    A short cut review was carried out to establish whether testing for troponin levels is useful after discharge of an Implanted Cardioverter-Defibrillator (ICD). Many papers were found using the reported searches, none of which directly addressed the problem but some 13 presented the best evidence to answer the clinical question. The author, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of those best papers are tabulated. It is concluded that the number of ICD discharges must be taken into account when evaluating any troponin level rise. Overall a positive troponin assay post ICD discharge is independently associated with an increased mortality.

  3. MELAS Syndrome with Cardiac Involvement: A Multimodality Imaging Approach

    Directory of Open Access Journals (Sweden)

    Sara Seitun

    2016-01-01

    Full Text Available A 49-year-old man presented with chest pain, dyspnea, and lactic acidosis. Left ventricular hypertrophy and myocardial fibrosis were detected. The sequencing of mitochondrial genome (mtDNA revealed the presence of A to G mtDNA point mutation at position 3243 (m.3243A>G in tRNALeu(UUR gene. Diagnosis of cardiac involvement in a patient with Mitochondrial Encephalomyopathy, Lactic Acidosis, and Stroke-like episodes syndrome (MELAS was made. Due to increased risk of sudden cardiac death, cardioverter defibrillator was implanted.

  4. Radiofrequency ablation of fast ventricular tachycardia causing an ICD storm in an infant with hypertrophic cardiomyopathy.

    Science.gov (United States)

    Ergul, Yakup; Ozyilmaz, Isa; Bilici, Meki; Ozturk, Erkut; Haydin, Sertaç; Guzeltas, Alper

    2018-04-01

    An implantable cardioverter defibrillator (ICD) storm involves very frequent arrhythmia episodes and ICD shocks, and it is associated with poor short-term and long-term prognosis. Radiofrequency catheter ablation can be used as an effective rescue treatment for patients with an ICD storm. To our knowledge, this is the first report of an infant with hypertrophic cardiomyopathy presenting with an ICD storm and undergoing successful radiofrequency catheter ablation salvage treatment for the fast left posterior fascicular ventricular tachycardia. © 2017 Wiley Periodicals, Inc.

  5. Statins as anti-arrhythmics: a systematic review part II: effects on risk of ventricular arrhythmias.

    Science.gov (United States)

    Abuissa, Hussam; O'Keefe, James H; Bybee, Kevin A

    2009-10-01

    Recent studies have demonstrated that statins may possess anti-arrhythmic properties in addition to their lipid-lowering effects. Studies which reported the association of statins with the incidence of ventricular arrhythmias were identified through a systematic review of the published literature. Statins have been associated with a significant reductions in ventricular arrhythmia in cardiomyopathy patients with an implantable cardioverter defibrillator, although randomized trials have not been completed. Published data suggests that statins may possess anti-arrhythmic properties that reduce the propensity for ventricular arrhythmias. Most of this data is observational; more randomized, placebo-controlled trials are needed.

  6. Assessment of relationships between novel inflammatory markers and presence and severity of preeclampsia: Epicardial fat thickness, pentraxin-3, and neutrophil-to-lymphocyte ratio.

    Science.gov (United States)

    Cakmak, Huseyin Altug; Dincgez Cakmak, Burcu; Abide Yayla, Cigdem; Inci Coskun, Ebru; Erturk, Mehmet; Keles, Ibrahim

    2017-08-01

    The aim of this study was to evaluate the relation of three new inflammatory markers with presence and severity of preeclampsia and to compare the predictive values of all markers for presence of this setting. In this study, a total of 100 consecutive pregnants with a diagnosis of preeclampsia and 40 healthy pregnants between October 2014 and April 2015 were included. Epicardial fat tissue was calculated by two-dimensional transthoracic echocardiography, and pentraxin-3 and neutrophil-to-lymphocyte ratio were measured by using an enzyme-linked immunosorbent assay method and routine blood count analysis, respectively. Epicardial fat thickness (p preeclampsia as compared to the healthy pregnants. Furthermore, epicardial fat thickness (p = 0.002), pentraxin-3 (p preeclampsia compared to mild preeclampsia. In the multivariate analysis, epicardial fat thickness (p = 0.013), pentraxin-3 (p = 0.04), and neutrophil-to-lymphocyte ratio (p preeclampsia after adjusting for other risk factors. Epicardial fat thickness, neutrophil-to-lymphocyte ratio, and pentraxin-3 are important markers that provide an additional information beyond that provided by conventional methods in predicting presence and severity of preeclampsia.

  7. MRI in patients with pacemakers? First global consensus recommendations from radiologists and cardiologists

    International Nuclear Information System (INIS)

    Heindel, Walter; Kugel, Harald

    2017-01-01

    Under the title ''MR Imaging in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators'', this issue of Roefo - simultaneously with the journal of the German Cardiac Society ''Der Kardiologe'' - presents a consensus paper of the German Roentgen Society and the German Cardiac Society [1] [2] that was jointly written by the authors in radiology and cardiology but does not exclusively address cardiac MRI. This publication relates to MR imaging of all regions of the body. In Germany and internationally the number of MRI examinations is increasing: 1,008,944 examinations were performed on patients receiving inpatient treatment in 2005 while 1,767,005 examinations were performed in 2013 (DRG hospitals). This development can be attributed to our aging population as well as to new indications for MRI including: Analyses of tissue composition and function, for example in the liver [3] [4] and the heart [5] [6]; multiparametric analyses of MR perfusion, e.g. in treated brain tumors [7]; new organs such as the lung [8]; dedicated examinations for intervention planning and operation monitoring [9] [10] [11]; as well as MRI-guided interventions [12] [13] [14] [15] [16]. Implants must always be considered in all of these MRI examinations even if the reason for the examination request is not related to an implant. The involvement of cardiology in this case is not based on the medical issue but rather on the type of implant. Expertise in cardiology is required when dealing with cardiac pacemakers (PM) and implantable cardioverter defibrillators (ICD).

  8. Increased Regional Epicardial Fat Volume Associated with Reversible Myocardial Ischemia in Patients with Suspected Coronary Artery Disease

    Science.gov (United States)

    Khawaja, Tuba; Greer, Christine; Thadani, Samir R.; Kato, Tomoko S.; Bhatia, Ketan; Shimbo, Daichi; Konkak, Andrew; Bokhari, Sabahat; Einstein, Andrew J.; Schulze, P. Christian

    2015-01-01

    Epicardial adipose tissue is a source of pro-inflammatory cytokines and has been linked to the development of coronary artery disease. No study has systematically assessed the relationship between local epicardial fat volume (EFV) and myocardial perfusion defects. We analyzed EFV in patients undergoing SPECT myocardial perfusion imaging combined with computed tomography (CT) for attenuation correction. Low-dose CT without contrast was performed in 396 consecutive patients undergoing SPECT imaging for evaluation of coronary artery disease. Regional thickness, cross-sectional areas, and total EFV were assessed. 295 patients had normal myocardial perfusion scans and 101 had abnormal perfusion scans. Mean EFVs in normal, ischemic, and infarcted hearts were 99.8 ± 82.3 cm3, 156.4 ± 121.9 cm3, and 96.3 ± 102.1 cm3, respectively (P < 0.001). Reversible perfusion defects were associated with increased local EFV compared to normal perfusion in the distribution of the right (69.2 ± 51.5 vs 46.6 ± 32.0 cm3; P = 0.03) and left anterior descending coronary artery (87.1 ± 76.4 vs 46.7 ± 40.6 cm3; P = 0.005). Our results demonstrate increased regional epicardial fat in patients with active myocardial ischemia compared to patients with myocardial scar or normal perfusion on nuclear perfusion scans. Our results suggest a potential role for cardiac CT to improve risk stratification in patients with suspected coronary artery disease. PMID:25339129

  9. Role of miRNAs in Epicardial Adipose Tissue in CAD Patients with T2DM

    Directory of Open Access Journals (Sweden)

    Yang Liu

    2016-01-01

    Full Text Available Background. Epicardial adipose tissue (EAT is identified as an atypical fat depot surrounding the heart with a putative role in the involvement of metabolic disorders, including obesity, type-2 diabetes mellitus, and atherosclerosis. We profiled miRNAs in EAT of metabolic patients with coronary artery disease (CAD and type-2 diabetes mellitus (T2DM versus metabolically healthy patients by microarray. Compared to metabolically healthy patients, we identified forty-two miRNAs that are differentially expressed in patients with CAD and T2DM from Xinjiang, China. Eleven miRNAs were selected as potential novel miRNAs according to P value and fold change. Then the potential novel miRNAs targeted genes were predicted via TargetScan, PicTar, and miRTarbase, and the function of the target genes was predicted via Gene Ontology (GO analysis while the enriched KEGG pathway analyses of the miRNAs targeted genes were performed by bioinformatics software DAVID. Then protein-protein interaction networks of the targeted gene were conducted by online software STRING. Finally, using microarray, bioinformatics approaches revealed the possible molecular mechanisms pathogenesis of CAD and T2DM. A total of 11 differentially expressed miRNAs were identified and among them, hsa-miR-4687-3p drew specific attention. Bioinformatics analysis revealed that insulin signaling pathway is the central way involved in the progression of metabolic disorders. Conclusions. The current findings support the fact that miRNAs are involved in the pathogenesis of metabolic disorders in EAT of CAD patients with T2DM, and validation of the results of these miRNAs by independent and prospective study is certainly warranted.

  10. Association Between Epicardial Fat Thickness and Premature Coronary Artery Disease: A Case Control Study

    Science.gov (United States)

    Faghihi, Shadi; Vasheghani-Farahani, Ali; Parsaee, Mozhgan; Saedi, Sedigheh; Ghadrdoost, Behshid

    2015-01-01

    Background: The association between epicardial fat thickness (EFT) and premature coronary artery disease (CAD) has not been elaborately studied. Objectives: In the present study, we sought whether such a relationship between EFT and CAD exists. Patients and Methods: Sixty two consecutive subjects, under 50 years of age, who underwent coronary angiography (CAG) with the aspect of CAD, were included in this case control study. They were divided into two groups of 31 subjects, namely CAD (cases) and non-CAD (controls) group, according to CAG data. Presence of conventional coronary risk factors, drug history, and anthropometric data were recorded. Then, each subject underwent standard transthoracic echocardiography for measuring EFT in the proximal part of right ventricular outflow tract in the parasternal long axis view at end diastole, as well as other parameters of systolic and diastolic function, and left ventricle (LV) mass. Images were stored for offline analysis when the echocardiocardiographers were blind to CAG data. Results: Among baseline characteristics, waist circumference, triglyceride levels, cigarette smoking and history of statin use were significantly higher in the CAD group. The body mass index (BMI) was significantly higher in the non-CAD group. According to echocardiographic data, the EFT with a cut off value of 2.95 mm could well differentiate subjects in each group. The LV mass and E/e were significantly higher in CAD group, in addition to EFT. Also, there was a significant correlation between EFT and waist circumference, as well as LV mass. However, no significant relation was between EFT and LV systolic and diastolic function. Conclusions: The EFT, as measured by echocardiography, with a cut off value 2.95 mm has a strong association with premature CAD. PMID:26380819

  11. Automated quantification of epicardial adipose tissue using CT angiography: evaluation of a prototype software

    Energy Technology Data Exchange (ETDEWEB)

    Spearman, James V.; Silverman, Justin R.; Krazinski, Aleksander W.; Costello, Philip [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Meinel, Felix G.; Geyer, Lucas L. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Ludwig-Maximilians-University Hospital, Institute for Clinical Radiology, Munich (Germany); Schoepf, U.J. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Apfaltrer, Paul [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University Medical Center Mannheim, Medical Faculty Mannheim - Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, Mannheim (Germany); Canstein, Christian [Siemens Medical Solutions USA, Inc., Malvern, PA (United States); De Cecco, Carlo Nicola [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' - Polo Pontino, Department of Radiological Sciences, Oncology and Pathology, Latina (Italy)

    2014-02-15

    This study evaluated the performance of a novel automated software tool for epicardial fat volume (EFV) quantification compared to a standard manual technique at coronary CT angiography (cCTA). cCTA data sets of 70 patients (58.6 ± 12.9 years, 33 men) were retrospectively analysed using two different post-processing software applications. Observer 1 performed a manual single-plane pericardial border definition and EFV{sub M} segmentation (manual approach). Two observers used a software program with fully automated 3D pericardial border definition and EFV{sub A} calculation (automated approach). EFV and time required for measuring EFV (including software processing time and manual optimization time) for each method were recorded. Intraobserver and interobserver reliability was assessed on the prototype software measurements. T test, Spearman's rho, and Bland-Altman plots were used for statistical analysis. The final EFV{sub A} (with manual border optimization) was strongly correlated with the manual axial segmentation measurement (60.9 ± 33.2 mL vs. 65.8 ± 37.0 mL, rho = 0.970, P < 0.001). A mean of 3.9 ± 1.9 manual border edits were performed to optimize the automated process. The software prototype required significantly less time to perform the measurements (135.6 ± 24.6 s vs. 314.3 ± 76.3 s, P < 0.001) and showed high reliability (ICC > 0.9). Automated EFV{sub A} quantification is an accurate and time-saving method for quantification of EFV compared to established manual axial segmentation methods. (orig.)

  12. Triiodothyronine promotes the proliferation of epicardial progenitor cells through the MAPK/ERK pathway.

    Science.gov (United States)

    Deng, Song-Bai; Jing, Xiao-Dong; Wei, Xiao-Ming; Du, Jian-Lin; Liu, Ya-Jie; Qin, Qin; She, Qiang

    2017-04-29

    Thyroid hormone has important functions in the development and physiological function of the heart. The aim of this study was to determine whether 3,5,3'-Triiodothyronine (T3) can promote the proliferation of epicardial progenitor cells (EPCs) and to investigate the potential underlying mechanism. Our results showed that T3 significantly promoted the proliferation of EPCs in a concentration- and time-dependent manner. The thyroid hormone nuclear receptor inhibitor bisphenol A (100 μmol/L) did not affect T3's ability to induce proliferation. Further studies showed that the mRNA expression levels of mitogen-activated protein kinase 1 (MAPK1), MAPK3, and Ki67 in EPCs in the T3 group (10 nmol/L) increased 2.9-, 3-, and 4.1-fold, respectively, compared with those in the control group (P < 0.05). In addition, the mRNA expression of the cell cycle protein cyclin D1 in the T3 group increased approximately 2-fold compared with the control group (P < 0.05), and there were more EPCs in the S phase of the cell cycle (20.6% vs. 12.0%, P < 0.05). The mitogen-activated protein kinase/extracellular signal-regulated kinase (MAPK/ERK) signaling pathway inhibitor U0126 (10 μmol/L) significantly inhibited the ability of T3 to promote the proliferation of EPCs and to alter cell cycle progression. This study suggested that T3 significantly promotes the proliferation of EPCs, and this effect may be achieved through activation of the MAPK/ERK signaling pathway. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. A SHORT-TERM CIRCUIT RESISTANCE PROGRAMME REDUCED EPICARDIAL FAT IN OBESE AGED WOMEN.

    Science.gov (United States)

    Rosety, Miguel Angel; Pery, Maria Teresa; Rodriguez-Pareja, Maria Antonia; Diaz, Antonio; Rosety, Jesus; Garcia, Natalia; Brenes-Martin, Francisco; Rosety-Rodríguez, Manuel; Toro, Rocío; Ordoñez, Francisco Javier; Rosety, Ignacio

    2015-11-01

    this study was conducted to ascertain the effects of resistance circuit training on epicardial adipose tissue (EAT) in obese aged women. A secondary objective was to assess muscle damage induced by supervised resistance training to confirm the intervention program was effective and safe. in the present interventional study, a total of 48 obese aged women were recruited from the community. Twenty-four of them were randomly assigned to perform a 12-week resistance circuit training programme, 3-days per week. This training was circularly performed in 6 stations: arm curl, leg extension, seated row, leg curl, triceps extension and leg press. The Jamar handgrip electronic dynamometer was used to assess maximal handgrip strength of the dominant hand. Two experienced observers assessed EAT by transthoracic two-dimensional echocardiography. Lastly, serum samples were analysed using one-step sandwich assays for creatine kinase activity (CK) and myoglobin (MB) concentration. as was hypothesized, resistance training significantly reduced EAT thickness (8.4 ± 1.0 vs. 7.3 ± 1.3 mm; p = 0.014; d = 0.76) in the experimental group. Resistance training induced no significant changes in markers of muscle damage such as CK (181.6 ± 36.9 vs. 194.2 ± 37.8 U/l; p = 0.31) and MB (62.4 ± 7.1 vs. 67.3 ± 7.7 ng/ml; p = 0.26). No significant changes in any of the tested outcomes were found in the control group. resistance training reduced EAT in aged obese women. A secondary finding was that the training program was effective and safe. While current results are promising, future studies are still required to consolidate this approach in clinical application. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  14. Target vessel detection by epicardial ultrasound in off-pump coronary bypass surgery.

    Science.gov (United States)

    Hayakawa, Masato; Asai, Tohru; Kinoshita, Takeshi; Suzuki, Tomoaki; Shiraishi, Shoichiro

    2013-01-01

    The detection of embedded coronary arteries is difficult especially in off-pump coronary bypass surgery. From June 2010, we introduced high-frequency epicardial ultrasound (ECUS) to assess and evaluate embedded arteries during off-pump coronary bypass surgery. Between June 2010 and June 2011, a total of 89 consecutive patients underwent isolated coronary bypass surgery at our institution. The patients consisted of 72 men and 17 women with a mean age of 67.9 years. We routinely use the VeriQC system (MediStim, Oslo, Norway) to detect the target vessels in the operation. The patients were assigned to one of two groups, depending on whether ECUS was used in the operation (n = 10, ECUS group) or not (n = 79, non-ECUS group). We analyzed the impact of introducing the ECUS in terms of operative outcome. All patients underwent revascularization using the off-pump technique without emergent conversion to cardiopulmonary bypass during surgery. The total number of distal anastomoses was 299, and 12 target vessels could not be identified either visually or on palpation. Thus, the frequency of the embedded coronary arteries was 4.01% (12/299 cases). The preoperative profiles of the two groups were not significantly different. Operation time was significantly longer in the ECUS group (P = 0.02). There were no significant differences in postoperative outcome between the two groups. In the present study, in which the target coronary arteries could not be detected either visually or on palpation in 12 (4.01%) of 299 cases, the use of high-frequency ECUS allowed all patients to undergo off-pump coronary bypass surgery without conversion to cardiopulmonary bypass during the operation. High-frequency ECUS is therefore useful in off-pump coronary bypass surgery.

  15. Epicardial adipose tissue volume and adipocytokine imbalance are strongly linked to human coronary atherosclerosis.

    Science.gov (United States)

    Shimabukuro, Michio; Hirata, Yoichiro; Tabata, Minoru; Dagvasumberel, Munkhbaatar; Sato, Hiromi; Kurobe, Hirotsugu; Fukuda, Daiju; Soeki, Takeshi; Kitagawa, Tetsuya; Takanashi, Shuichiro; Sata, Masataka

    2013-05-01

    The impact of epicardial adipose tissue (EAT) over abdominal or overall adiposity on coronary artery disease (CAD) is currently unknown. We compared the association among EAT volume (EATV), cytokine/adipocytokine profiles in EAT and subcutaneous fat, and atherogenic CAD. Paired samples were obtained from EAT and subcutaneous adipose tissue during elective cardiac surgery for CAD (n=50) or non-CAD (n=50). EATV was the sum of cross-sectional EAT areas, and visceral and subcutaneous fat areas were determined at the umbilicus level on computed tomography scans. CD68(+), CD11c(+), and CD206(+) cells were counted using immunohistochemical staining. Cytokine/adipocytokine expression was evaluated using quantitative real-time polymerase chain reaction. Multivariate analysis indicated that male sex, age, diabetes mellitus, high triglycerides, and low high-density lipoprotein cholesterol, and EATV index (EATV/body surface area, cm(3)/m(2)) were significant CAD predictors (corrected R(2)=0.401; PEATV index positively correlated with the CD68(+) and CD11c(+) cell numbers and nucleotide-binding domain, leucine-rich-containing family, pyrin domain-containing-3 (NLRP3), interleukin-1β, and interleukin-1R expression; and negatively correlated with adiponectin expression in EAT. A multivariate analysis model, including CD68(+) cells and interleukin-1β, and adiponectin expression in EAT strongly predicted CAD (corrected R(2)=0.756; PEATV and macrophage and cytokine/adipocytokine signals in EAT strongly correlated with CAD. Our findings suggest that EATV and adipocytokine imbalance are strongly linked to human coronary atherosclerosis.

  16. Influence of technical parameters on epicardial fat volume quantification at cardiac CT.

    Science.gov (United States)

    Bucher, Andreas M; Joseph Schoepf, U; Krazinski, Aleksander W; Silverman, Justin; Spearman, James V; De Cecco, Carlo N; Meinel, Felix G; Vogl, Thomas J; Geyer, Lucas L

    2015-06-01

    To systematically analyze the influence of technical parameters on quantification of epicardial fat volume (EATV) at cardiac CT. 153 routine cardiac CT data sets were analyzed using three-dimensional pericardial border delineation. Three image series were reconstructed per patient: (a) CTAD: coronary CT angiography (CTA), diastolic phase; (b) CTAS: coronary CTA, systolic phase; (c) CaScD: non-contrast CT, diastolic phase. EATV was calculated using three different upper thresholds (-15HU, -30 HU, -45HU). Repeated measures ANOVA, Spearman's rho, and Bland Altman plots were used. Mean EATV differed between all three image series at a -30HU threshold (CTAD 87.2 ± 38.5 ml, CTAS 90.9 ± 37.7 ml, CaScD 130.7 ± 49.5 ml, PEATV of diastolic and systolic CTA reconstructions did not differ significantly (P=0.225). Mean EATV for contrast enhanced CTA at a -15HU threshold (CTAD15 102.4 ± 43.6 ml, CTAS15 105.3 ± 42.3 ml) could be approximated most closely by non-contrast CT at -45HU threshold (CaScD45 105.3 ± 40.8 ml). The correlation was excellent: CTAS15-CTAD15, rho=0.943; CTAD15-CaScD45, rho=0.905; CTAS15-CaScD45, rho=0.924; each PEATV can differ substantially between contrast enhanced and non-contrast CT studies, which can be reconciled by threshold modification. Heart cycle phase does not significantly influence EATV measurements. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Lagrangian displacement tracking using a polar grid between endocardial and epicardial contours for cardiac strain imaging.

    Science.gov (United States)

    Ma, Chi; Varghese, Tomy

    2012-04-01

    Accurate cardiac deformation analysis for cardiac displacement and strain imaging over time requires Lagrangian description of deformation of myocardial tissue structures. Failure to couple the estimated displacement and strain information with the correct myocardial tissue structures will lead to erroneous result in the displacement and strain distribution over time. Lagrangian based tracking in this paper divides the tissue structure into a fixed number of pixels whose deformation is tracked over the cardiac cycle. An algorithm that utilizes a polar-grid generated between the estimated endocardial and epicardial contours for cardiac short axis images is proposed to ensure Lagrangian description of the pixels. Displacement estimates from consecutive radiofrequency frames were then mapped onto the polar grid to obtain a distribution of the actual displacement that is mapped to the polar grid over time. A finite element based canine heart model coupled with an ultrasound simulation program was used to verify this approach. Segmental analysis of the accumulated displacement and strain over a cardiac cycle demonstrate excellent agreement between the ideal result obtained directly from the finite element model and our Lagrangian approach to strain estimation. Traditional Eulerian based estimation results, on the other hand, show significant deviation from the ideal result. An in vivo comparison of the displacement and strain estimated using parasternal short axis views is also presented. Lagrangian displacement tracking using a polar grid provides accurate tracking of myocardial deformation demonstrated using both finite element and in vivo radiofrequency data acquired on a volunteer. In addition to the cardiac application, this approach can also be utilized for transverse scans of arteries, where a polar grid can be generated between the contours delineating the outer and inner wall of the vessels from the blood flowing though the vessel.

  18. Carmustine Implant

    Science.gov (United States)

    ... works by slowing or stopping the growth of cancer cells in your body. ... are pregnant, plan to become pregnant, or are breast-feeding. If you become pregnant while receiving carmustine implant, call your doctor. Carmustine may harm the fetus.

  19. Cochlear Implants

    Science.gov (United States)

    ... NIDCD A cochlear implant is a small, complex electronic device that can help to provide a sense ... Hearing Aids Retinitis Pigmentosa - National Eye Institute Telecommunications Relay Services Usher Syndrome Your Baby's Hearing Screening News ...

  20. Epicardial and Subcutaneous Adipose Tissue Fatty Acids Profiles in Diabetic and Non-Diabetic Patients Candidate for Coronary Artery Bypass Graft

    Directory of Open Access Journals (Sweden)

    Masoud Pezeshkian

    2013-01-01

    Full Text Available Introduction: We have recently shown that in high cholesterol-fed rabbits, the sensitivity of epicardial adipose tissue to changes in dietary fat is higher than that of subcutaneous adipose tissue. Although the effects of diabetes on epicardial adipose tissue thickness have been studied, the influence of diabetes on profile of epicardial free fatty acids (FFAs has not been studied. The aim of this study is to investigate the effect of diabetes on the FFAs composition in serum and in the subcutaneous and epicardial adipose tissues in patients undergoing coronary artery bypass graft (CABG. Methods: Forty non-diabetic and twenty eight diabetic patients candidate for CABG with > 75% stenosis participated in this study.Fasting blood sugar (FBS and lipid profiles were assayed by auto analyzer. Phospholipids and non-estrified FFA of serum and the fatty acids profile of epicardial and subcutaneous adipose tissues were determined using gas chromatography method. Results: In the phospholipid fraction of diabetic patients’ serum, the percentage of 16:0, 18:3n-9, 18:2n-6 and monounsaturated fatty acids (MUFAs was lower than the corresponding values of the non-diabetics; whereas, 18:0 value was higher. A 100% increase in the amount of 18:0 and 35% decrease in the level of 18:1n-11 was observed in the diabetic patients’ subcutaneous adipose tissue. In epicardial adipose tissue, the increase of 18:0 and conjugated linolenic acid (CLA and decrease of 18:1n-11, ω3 (20:5n-3 and 22:6n-3 were significant; but, the contents of arachidonic acid and its precursor linoleic acid were not affected by diabetes. Conclusion: The fatty acids’ profile of epicardial and subcutaneous adipose tissues is not equally affected by diabetes. The significant decrease of 16:0 and ω3 fatty acids and increase of trans and conjugated fatty acids in epicardial adipose tissue in the diabetic patients may worsen the formation of atheroma in the related arteries.

  1. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    The implantation and sputtering mechanisms which are relevant to ion bombardment of surfaces are described. These are: collision, thermal, electronic and photon-induced sputtering. 135 refs.; 36 figs.; 9 tabs

  2. Thickening of the epicardial adipose tissue can be alleviated by thyroid hormone replacement therapy in patients with subclinical hypothyroidism.

    Science.gov (United States)

    Sayin, Irmak; Erkan, Aycan Fahri; Ekici, Berkay; Kutuk, Utku; Corakci, Ahmet; Tore, Hasan Fehmi

    2016-01-01

    Subclinical hypothyroidism (SCH) is a common disorder which has adverse cardiovascular effects. Epicardial adipose tissue (EAT), a novel marker of cardiovascular risk, is increased in SCH. We aimed to investigate whether L-thyroxine treatment can reverse the thickening of EAT in SCH. Forty-four patients with SCH and 42 euthyroid control subjects were included. EAT thickness was measured using transthoracic echocardiography at baseline and after restoration of the euthyroid status with 3 months of L-thyroxine treatment. At baseline, mean EAT thickness was significantly greater in the SCH group when compared to the control group (6.3 ± 1.7 mm vs. 4.1 ± 0.9 mm, respectively, p treatment (6.3 ± 1.7 mm vs. 5.1 ± 1.4 mm, p treatment when compared to baseline (DEAT) significantly correlated to the difference in TSH levels before and after treatment (DTSH; r = 0.323; p = 0.032). Epicardial adipose tissue thickness is increased in patients with SCH. This thickening was alleviated with restoration of the euthyroid status with L-thyroxine treatment in our study population of predominantly male, relatively old subjects with greater baseline EAT thickness.

  3. Increased epicardial fat is independently associated with the presence and chronicity of atrial fibrillation and radiofrequency ablation outcome

    Energy Technology Data Exchange (ETDEWEB)

    Stojanovska, Jadranka; Kazerooni, Ella A.; Gross, Barry H.; Patel, Smita [University of Michigan Health System, Department of Radiology, Division of Cardiothoracic Radiology, UH B1-132 Taubman/Box 0302, Ann Arbor, MI (United States); Sinno, Mohamad; Oral, Hakan [University of Michigan Health System, Department of Internal Medicine, Cardiovascular Medicine, Electrophysiology Laboratory, Cardiovascular Center, Ann Arbor, MI (United States); Watcharotone, Kuanwong [University of Michigan, Michigan Institute for Clinical and Health Research (MICHR), Ann Arbor, MI (United States); Jacobson, Jon A. [University of Michigan Health System, Department of Radiology, Division of Musculoskeletal Radiology, Ann Arbor, MI (United States)

    2015-08-15

    To determine whether intrathoracic fat volumes are associated with presence and chronicity of atrial fibrillation (AF) and radiofrequency ablation (RFA) treatment outcome. IRB approval was obtained and patient consent was waived for this HIPAA-compliant retrospective study. 169 patients with AF (75 non-paroxysmal and 94 paroxysmal) and 62 control patients underwent cardiac CT examination. Extrapericardial (EPFV) and epicardial fat volumes (EFV) were measured on CT, the sum of which is the total intrathoracic fat volume. Associations between these three fat volumes and presence and chronicity of AF, and outcome after RFA, were evaluated using logistic regression analysis. EFV was significantly associated with presence [OR 1.01 (95 % CI 1.003-1.03), p = 0.01], chronicity of AF [1.008 (1.001-1.020), p = 0.03] and AF recurrence after RFA [1.009 (1.001-1.01), p = 0.02] after adjustment for age, gender and BMI. Patients with a larger EFV had a shorter time to AF recurrence (p = 0.017) and a higher rate of recurrence (54 % vs 46 %) (p = 0.002) after RFA. EPFV had no significant associations. Increased epicardial fat is associated with the presence and chronicity of AF, a higher probability of AF recurrence after RFA and a shorter AF-free interval. (orig.)

  4. Adipogenesis and epicardial adipose tissue: a novel fate of the epicardium induced by mesenchymal transformation and PPARγ activation.

    Science.gov (United States)

    Yamaguchi, Yukiko; Cavallero, Susana; Patterson, Michaela; Shen, Hua; Xu, Jian; Kumar, S Ram; Sucov, Henry M

    2015-02-17

    The hearts of many mammalian species are surrounded by an extensive layer of fat called epicardial adipose tissue (EAT). The lineage origins and determinative mechanisms of EAT development are unclear, in part because mice and other experimentally tractable model organisms are thought to not have this tissue. In this study, we show that mouse hearts have EAT, localized to a specific region in the atrial-ventricular groove. Lineage analysis indicates that this adipose tissue originates from the epicardium, a multipotent epithelium that until now is only established to normally generate cardiac fibroblasts and coronary smooth muscle cells. We show that adoption of the adipocyte fate in vivo requires activation of the peroxisome proliferator activated receptor gamma (PPARγ) pathway, and that this fate can be ectopically induced in mouse ventricular epicardium, either in embryonic or adult stages, by expression and activation of PPARγ at times of epicardium-mesenchymal transformation. Human embryonic ventricular epicardial cells natively express PPARγ, which explains the abundant presence of fat seen in human hearts at birth and throughout life.

  5. Increased epicardial fat volume quantified by 64-multidetector computed tomography is associated with coronary atherosclerosis and totally occlusive lesions

    International Nuclear Information System (INIS)

    Ueno, Koji; Anzai, Toshihisa; Jinzaki, Masahiro

    2009-01-01

    The relationship between the epicardial fat volume measured by 64-slice multidetector computed tomography (MDCT) and the extension and severity of coronary atherosclerosis was investigated. Both MDCT and conventional coronary angiography (CAG) were performed in 71 consecutive patients who presented with effort angina. The volume of epicardial adipose tissue (EAT) was measured by MDCT. The severity of coronary atherosclerosis was assessed by evaluating the extension of coronary plaques in 790 segments using MDCT data, and the percentage diameter stenosis in 995 segments using CAG data. The estimated volume of EAT indexed by body surface area was defined as VEAT. Increased VEAT was associated with advanced age, male sex, degree of metabolic alterations, a history of acute coronary syndrome (ACS) and the presence of total occlusions, and showed positive correlation with the stenosis score r=0.28, P=0.02) and the atheromatosis score (r=0.67, P 3 /m 2 ) to be the strongest independent determinant of the presence of total occlusions odds ratio 4.64. P=0.02). VEAT correlates with the degree of metabolic alterations and coronary atheromatosis. Excessive accumulation of EAT might contribute to the development of ACS and coronary total occlusions. (author)

  6. Epicardial distribution of ST segment and T wave changes produced by stimulation of intrathoracic ganglia or cardiopulmonary nerves in dogs.

    Science.gov (United States)

    Savard, P; Cardinal, R; Nadeau, R A; Armour, J A

    1991-06-01

    Sixty-three ventricular epicardial electrograms were recorded simultaneously in 8 atropinized dogs during stimulation of acutely decentralized intrathoracic autonomic ganglia or cardiopulmonary nerves. Three variables were measured: (1) isochronal maps representing the epicardial activation sequence, (2) maps depicting changes in areas under the QRS complex and T wave (regional inhomogeneity of repolarization), and (3) local and total QT intervals. Neural stimulations did not alter the activation sequence but induced changes in the magnitude and polarity of the ST segments and T waves as well as in QRST areas. Stimulation of the same neural structure in different dogs induced electrical changes with different amplitudes and in different regions of the ventricles, except for the ventral lateral cardiopulmonary nerve which usually affected the dorsal wall of the left ventricle. Greatest changes occurred when the right recurrent, left intermediate medial, left caudal pole, left ventral lateral cardiopulmonary nerves and stellate ganglia were stimulated. Local QT durations either decreased or did not change, whereas total QT duration as measured using a root-mean-square signal did not change, indicating the regional nature of repolarization changes. Taken together, these data indicate that intrathoracic efferent sympathetic neurons can induce regional inhomogeneity of repolarization without prolonging the total QT interval.

  7. Changes in arterial stiffness, carotid intima-media thickness, and epicardial fat after L-thyroxine replacement therapy in hypothyroidism.

    Science.gov (United States)

    del Busto-Mesa, Abdel; Cabrera-Rego, Julio Oscar; Carrero-Fernández, Lisván; Hernández-Roca, Cristina Victoria; González-Valdés, Jorge Luis; de la Rosa-Pazos, José Eduardo

    2015-01-01

    To assess the relationship between primary hypothyroidism and subclinical atherosclerosis and its potential changes with L-thyroxine replacement therapy. A prospective cohort study including 101 patients with primary hypothyroidism and 101 euthyroid patients as controls was conducted from July 2011 to December 2013. Clinical, anthropometrical, biochemical, and ultrasonographic parameters were assessed at baseline and after one year of L-thyroxine replacement therapy. At baseline, hypothyroid patients had significantly greater values of blood pressure, total cholesterol, VLDL cholesterol, left ventricular mass, epicardial fat, and carotid intima-media thickness as compared to controls. Total cholesterol, VLDL cholesterol, ventricular diastolic function, epicardial fat, carotid intima-media thickness, carotid local pulse wave velocity, pressure strain elastic modulus, and β arterial stiffness index showed a significant and positive correlation with TSH levels. After one year of replacement therapy, patients with hypothyroidism showed changes in total cholesterol, VLDL cholesterol, TSH, carotid intima-media thickness, and arterial stiffness parameters. Primary hypothyroidism is characterized by an increased cardiovascular risk. In these patients, L-thyroxine replacement therapy for one year is related to decreased dyslipidemia and improvement in markers of subclinical carotid atherosclerosis. Copyright © 2014 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  8. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  9. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  10. The disconnect between the guidelines, the appropriate use criteria, and reimbursement coverage decisions: the ultimate dilemma.

    Science.gov (United States)

    Fogel, Richard I; Epstein, Andrew E; Mark Estes, N A; Lindsay, Bruce D; DiMarco, John P; Kremers, Mark S; Kapa, Suraj; Brindis, Ralph G; Russo, Andrea M

    Recently, the American College of Cardiology Foundation in collaboration with the Heart Rhythm Society published appropriate use criteria (AUC) for implantable cardioverter-defibrillators and cardiac resynchronization therapy. These criteria were developed to critically review clinical situations that may warrant implantation of an implantable cardioverter-defibrillator or cardiac resynchronization therapy device, and were based on a synthesis of practice guidelines and practical experience from a diverse group of clinicians. When the AUC was drafted, the writing committee recognized that some of the scenarios that were deemed "appropriate" or "may be appropriate" were discordant with the clinical requirements of many payers, including the Medicare National Coverage Determination (NCD). To charge Medicare for a procedure that is not covered by the NCD may be construed as fraud. Discordance between the guidelines, the AUC, and the NCD places clinicians in the difficult dilemma of trying to do the "right thing" for their patients, while recognizing that the "right thing" may not be covered by the payer or insurer. This commentary addresses these issues. Options for reconciling this disconnect are discussed, and recommendations to help clinicians provide the best care for their patients are offered. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Epicardial adipose tissue and pericoronary fat thickness measured with 64-multidetector computed tomography: potential predictors of the severity of coronary artery disease

    Directory of Open Access Journals (Sweden)

    Muhammed Bora Demircelik

    2014-06-01

    Full Text Available OBJECTIVE:The aim of the present study was to investigate the relationship between pericoronary fat and the severity and extent of atherosclerosis, quantified using 64-multidetector computed tomography, in patients with suspected coronary artery disease.METHODS:The study population consisted of 131 patients who were clinically referred for noninvasive multislice computed tomography coronary angiography for the evaluation of coronary artery disease. Patients were classified as follows: no atherosclerosis, Group 1; nonobstructive atherosclerosis (luminal narrowing <50% in diameter, Group 2; and obstructive atherosclerosis (luminal narrowing ≥50% in a single vessel or obstructive atherosclerosis in the left main coronary artery and/or multiple vessels, Group 3. Epicardial adipose tissue was defined as the adipose tissue between the surface of the heart and the visceral layer of the pericardium (visceral epicardium. Epicardial adipose tissue thickness (mm was determined in the right ventricular anterior free wall. The mean thickness of the pericoronary fat surrounding the three coronary arteries was used for the analyses.RESULTS:The average thickness over all three regions was 13.2 ± 2.1 mm. The pericoronary fat thickness was significantly increased in Group 3 compared with Groups 2 and 1. The epicardial adipose tissue thickness was significantly increased in Group 3 compared with Groups 2 and 1. A receiver operating characteristic curve for obstructive coronary artery disease was assessed to verify the optimum cut-off point for pericoronary fat thickness, which was 13.8 mm. A receiver operating characteristic curve for obstructive coronary artery disease was also assessed to verify the optimum cut-off point for epicardial adipose tissue, which was 6.8 cm.CONCLUSION:We showed that the epicardial adipose tissue and pericoronary fat thickness scores were higher in patients with obstructive coronary artery diseases.

  12. Epicardial adipose tissue and pericoronary fat thickness measured with 64-multidetector computed tomography: potential predictors of the severity of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Demircelik, Muhammed Bora; Gurel, Ozgul Malcok; Selcoki, Yusuf; Atar, Inci Asli; Eryonucu, Beyhan, E-mail: drdemircelik@yahoo.com [Turgut Ozal Univercity, Department of Cardiology, Ankara (Turkey); Bozkurt, Alper; Akin, Kayihan [Turgut Ozal Univercity, Department of Radiology, Ankara (Turkey); Yilmaz, Omer Caglar [Ankara Occupational Diseases Hospital, Department of Cardiology, Ankara (Turkey)

    2014-06-15

    Objective: the aim of the present study was to investigate the relationship between pericoronary fat and the severity and extent of atherosclerosis, quantified using 64-multidetector computed tomography, in patients with suspected coronary artery disease. Methods: the study population consisted of 131 patients who were clinically referred for noninvasive multislice computed tomography coronary angiography for the evaluation of coronary artery disease. Patients were classified as follows: no atherosclerosis, Group 1; nonobstructive atherosclerosis (luminal narrowing < 50% in diameter), Group 2; and obstructive atherosclerosis (luminal narrowing ≧ 50%) in a single vessel or obstructive atherosclerosis in the left main coronary artery and/or multiple vessels, Group 3. Epicardial adipose tissue was defined as the adipose tissue between the surface of the heart and the visceral layer of the pericardium (visceral epicardium). Epicardial adipose tissue thickness (mm) was determined in the right ventricular anterior free wall. The mean thickness of the pericoronary fat surrounding the three coronary arteries was used for the analyses. Results: the average thickness over all three regions was 13.2 ± 2.1 mm. The pericoronary fat thickness was significantly increased in Group 3 compared with Groups 2 and 1. The epicardial adipose tissue thickness was significantly increased in Group 3 compared with Groups 2 and 1. A receiver operating characteristic curve for obstructive coronary artery disease was assessed to verify the optimum cut-off point for pericoronary fat thickness, which was 13.8 mm. A receiver operating characteristic curve for obstructive coronary artery disease was also assessed to verify the optimum cut-off point for epicardial adipose tissue, which was 6.8 cm. Conclusion: we showed that the epicardial adipose tissue and pericoronary fat thickness scores were higher in patients with obstructive coronary artery diseases. (author)

  13. Epicardial adipose tissue and pericoronary fat thickness measured with 64-multidetector computed tomography: potential predictors of the severity of coronary artery disease

    International Nuclear Information System (INIS)

    Demircelik, Muhammed Bora; Gurel, Ozgul Malcok; Selcoki, Yusuf; Atar, Inci Asli; Eryonucu, Beyhan; Bozkurt, Alper; Akin, Kayihan; Yilmaz, Omer Caglar

    2014-01-01

    Objective: the aim of the present study was to investigate the relationship between pericoronary fat and the severity and extent of atherosclerosis, quantified using 64-multidetector computed tomography, in patients with suspected coronary artery disease. Methods: the study population consisted of 131 patients who were clinically referred for noninvasive multislice computed tomography coronary angiography for the evaluation of coronary artery disease. Patients were classified as follows: no atherosclerosis, Group 1; nonobstructive atherosclerosis (luminal narrowing < 50% in diameter), Group 2; and obstructive atherosclerosis (luminal narrowing ≧ 50%) in a single vessel or obstructive atherosclerosis in the left main coronary artery and/or multiple vessels, Group 3. Epicardial adipose tissue was defined as the adipose tissue between the surface of the heart and the visceral layer of the pericardium (visceral epicardium). Epicardial adipose tissue thickness (mm) was determined in the right ventricular anterior free wall. The mean thickness of the pericoronary fat surrounding the three coronary arteries was used for the analyses. Results: the average thickness over all three regions was 13.2 ± 2.1 mm. The pericoronary fat thickness was significantly increased in Group 3 compared with Groups 2 and 1. The epicardial adipose tissue thickness was significantly increased in Group 3 compared with Groups 2 and 1. A receiver operating characteristic curve for obstructive coronary artery disease was assessed to verify the optimum cut-off point for pericoronary fat thickness, which was 13.8 mm. A receiver operating characteristic curve for obstructive coronary artery disease was also assessed to verify the optimum cut-off point for epicardial adipose tissue, which was 6.8 cm. Conclusion: we showed that the epicardial adipose tissue and pericoronary fat thickness scores were higher in patients with obstructive coronary artery diseases. (author)

  14. The relationship between epicardial fat and indices of obesity and the metabolic syndrome: a systematic review and meta-analysis.

    Science.gov (United States)

    Rabkin, Simon W

    2014-02-01

    Epicardial fat (epicardial adipose tissue, EAT) has been implicated in the pathogenesis of coronary artery disease (CAD). The objective of this study was to examine the relationship between EAT and generalized obesity, central or visceral adipose tissue (VAT), and the components of the metabolic syndrome--systolic blood pressure (SBP), triglycerides (TGs), high-density lipoprotein cholesterol (HDL-C), and fasting blood glucose (FBG)--that are linked to CAD. A systematic review of the literature, following meta-analysis guidelines, was conducted until May, 2013, using the search strategy "Obesity" OR "abdominal obesity" OR "metabolic syndrome" OR "metabolic syndrome X" AND "epicardial fat". Thirty-eight studies fulfilled the criteria. There was a highly significant (Pcorrelation between EAT and body mass index (BMI), waist circumference (WC), or VAT. The correlation between EAT and VAT was significantly (Pcorrelation between EAT and WC, which in turn was significantly greater than the correlation between EAT and BMI. Overall, EAT was 7.5 ± 0.1 mm in thickness in the metabolic syndrome (n=427) compared to 4.0 ± 0.1 mm in controls (n=301). EAT correlated significantly (PHDL, and FBG, but the strength of the association was less than one-half of the relationship of EAT to indices of obesity. The results of multivariate analysis were less consistent but show a relationship between EAT and metabolic syndrome independent of BMI. In summary, the very strong correlation between EAT and VAT suggests a relationship between these two adipose tissue depots. Measurement of EAT can be useful to indicate VAT. Whereas EAT correlates significantly with each of the components of the metabolic syndrome- SBP, TGs, HDL, or FBG-the magnitude of the relationship is considerably and significantly less than the relationship of EAT to BMI. These data show the strong relationship between EAT and BMI but especially with WC and VAT. They also demonstrate the smaller magnitude of the

  15. Ventricular arrhythmias in Chagas disease

    Directory of Open Access Journals (Sweden)

    Marco Paulo Tomaz Barbosa

    2015-02-01

    Full Text Available Sudden death is one of the most characteristic phenomena of Chagas disease, and approximately one-third of infected patients develop life-threatening heart disease, including malignant ventricular arrhythmias. Fibrotic lesions secondary to chronic cardiomyopathy produce arrhythmogenic substrates that lead to the appearance and maintenance of ventricular arrhythmias. The objective of this study is to discuss the main clinical and epidemiological aspects of ventricular arrhythmias in Chagas disease, the specific workups and treatments for these abnormalities, and the breakthroughs needed to determine a more effective approach to these arrhythmias. A literature review was performed via a search of the PubMed database from 1965 to May 31, 2014 for studies of patients with Chagas disease. Clinical management of patients with chronic Chagas disease begins with proper clinical stratification and the identification of individuals at a higher risk of sudden cardiac death. Once a patient develops malignant ventricular arrhythmia, the therapeutic approach aims to prevent the recurrence of arrhythmias and sudden cardiac death by the use of implantable cardioverter defibrillators, antiarrhythmic drugs, or both. In select cases, invasive ab