  1. EPA flow reference method testing and analysis: Findings report

    International Nuclear Information System (INIS)

    1999-06-01

    This report describes an experimental program sponsored by the US Environmental Protection Agency (EPA) to evaluate potential improvements to the Agency's current reference method for measuring volumetric flow (Method 2, 40 CFR Part 60, Appendix B). Method 2 (Determination of Stack Gas Velocity and Volumetric Flow Rate (Type S Pitot Tube)) specifies measurements to determine volumetric flow, but does not prescribe specific procedures to account for yaw or pitch angles of flow when the flow in the stack is not axial. Method 2 also allows the use of only two probe types, the Type S and the Prandtl

  2. EPA scientists develop Federal Reference & Equivalent Methods for measuring key air pollutants

    Science.gov (United States)

    EPA operates a nationwide air monitoring network to measure six primary air pollutants: carbon monoxide, lead, sulfur dioxide, ozone, nitrogen dioxide, and particulate matter as part of its mission to protect human health and the environment.

  3. Hg0 and HgCl2 Reference Gas Standards: NIST Traceability and Comparability (And EPA ALT Methods for Hg and HCl )

    Science.gov (United States)

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the tru...

  4. The US EPA reference dose for methylmercury: sources of uncertainty

    International Nuclear Information System (INIS)

    Rice, D.C.

    2004-01-01

    The US Environmental Protection Agency (EPA) derived a reference dose for methylmercury in 2001, based on an extensive analysis by the National Research Council (NRC) of the National Academy of Sciences. The NRC performed benchmark dose analysis on a number of endpoints from three longitudinal prospective studies: the Seychelles Islands, the Faroe Islands, and the New Zealand studies. Adverse effects were reported in the latter two studies, but not in the Seychelles study. The NRC also performed an integrative analysis of all three studies. Dose conversion from cord blood or maternal hair mercury concentration was performed by EPA using a one-compartment pharmacokinetic model. A total uncertainty factor of 10 was applied for intrahuman pharmacokinetic and pharmacodynamic variability. There are numerous decisions made by the NRC/EPA that could greatly affect the value of the reference dose (RfD). Some of these include the choice of a linear model for the relationship between mercury body burden and neuropsychological performance, the choice of values of P 0 and the benchmark response, the use of the 'critical study/critical endpoint' approach in the interpretation of the maternal body burden that corresponds to the RfD, the use of central tendencies in a one-compartment pharmacokinetic model rather than the inclusion of the distributions of variables for the population of reproductive-age women, the assumption of unity for the ratio of fetal cord blood to maternal blood methylmercury concentrations, the choice of a total of 10 as an uncertainty factor, and the lack of dose-response analysis for other health effects such as cardiovascular disease. In addition, it may be argued that derivation of a RfD for methylmercury is inappropriate, given that there does not appear to be a threshold for adverse neuropsychological effects based on available data

  5. EPA's analytical methods for water: The next generation

    International Nuclear Information System (INIS)

    Hites, R.A.; Budde, W.L.

    1991-01-01

    By the late 1970s, it had become clear to EPA that organic compounds were polluting many of the nation's waters. By 1977, as a result of a lawsuit by several environmentally concerned plaintiffs, EPA had focused on a list of 114 'priority' organic pollutants. Its long-term goal was the regulation of specific compounds that were found to pose significant environmental problems, a daunting task. Tens of thousands of samples needed to be measured by hundreds of different laboratories. Clearly, there were concerns about the comparability of data among laboratories. The result was a series of laboratory-based analytical 'methods.' These EPA methods are detailed, step-by-step directions (recipes) that describe everything the analyst needs to know to complete a satisfactory analysis. During the 1970s the first set of methods was developed; this was the '600 series' for the analysis of organic compounds in wastewater. In 1979 and the 1980s, a set of '500 series' methods, focusing on drinking water, was developed. By now, many of the 500 and 600 series methods are in widespread use, and it is clear that there are considerably overlaps among the methods in terms of both procedures and analytes. Indiana University was asked by EPA to consider the question, 'Is it possible to revise or eliminate some of the 500 and 600 series methods and effect a savings of time and money?' This and related questions were studied and recommendations were developed

  6. Evaluation of mercury speciation by EPA (Draft) Method 29

    Energy Technology Data Exchange (ETDEWEB)

    Laudal, D.L.; Heidt, M.K. [Energy & Environmental Research Center, Grand Forks, ND (United States); Nott, B. [Electric Power Research Institute, Palo Alto, CA (United States)

    1995-11-01

    The 1990 Clean Air Act Amendments require that the U.S. Environmental protection Agency (EPA) assess the health risks associated with mercury emissions. Also, the law requires a separate assessment of health risks posed by the emission of 189 tract chemicals (including mercury) for electric utility steam-generating units. In order to conduct a meaningful assessment of health and environmental effects, we must have, among other things, a reliable and accurate method to measure mercury emissions. In addition, the rate of mercury deposition and the type of control strategies used may depend upon the type of mercury emitted (i.e., whether it is in the oxidized or elemental form). It has been speculated that EPA (Draft) Method 29 can speciate mercury by selective absorption; however, this claim has yet to be proven. The Electric Power Research Institute (EPRI) and the U.S. Department of Energy (DOE) have contracted with the Energy & Environmental Research Center (EERC) at University of North Dakota to evaluate EPA (Draft) Method 29 at the pilot-scale level. The objective of the work is to determine whether EPA (Draft) Method 29 can reliably quantify and speciate mercury in the flue gas from coal-fired boilers.

  7. EPA Method 1615. Measurement of Enterovirus and Norovirus ...

    Science.gov (United States)

    A standardized method is required when national studies on virus occurrence in environmental and drinking waters utilize multiple analytical laboratories. The U.S Environmental Protection Agency’s (USEPA) Method 1615 was developed with the goal of providing such a standard for measuring Enterovirus and Norovirus in these waters. Virus is concentrated from water using an electropositive filter, eluted from the filter surface with beef extract, and then concentrated further using organic flocculation. Herein we present the protocol from Method 1615 for filter elution, secondary concentration, and measurement of total culturable viruses. A portion of the concentrated eluate from each sample is inoculated onto ten replicate flasks of Buffalo Green Monkey kidney cells. The number of flasks demonstrating cytopathic effects is used to quantify the most probable number (MPN) of infectious units per liter. The method uses a number of quality controls to increase data quality and to reduce interlaboratory and intralaboratory variation. Laboratories must meet defined performance standards. Method 1615 was evaluated by examining virus recovery from reagent-grade and ground waters seeded with Sabin poliovirus type 3. Mean poliovirus recoveries with the total culturable assay were 111% in reagent grade water and 58% in groundwaters. EPA Method 1615 is being used by a number of national and international labs. This paper and the accompanying video will provide training oppo

  8. EPA Biofuels Research: Biofuel Vapor Generation and Monitoring Methods

    Science.gov (United States)

    The interest in renewable fuels and alternative energy sources has stimulated development of alternatives to traditional petroleum-based fuels. The EPA's Office of Transportation Air Quality (OTAQ) requires information regarding the potential health hazards ofthese fuels regardin...

  9. An Alternative to EPA Method 9 -- Field Validation of the Digital Opacity Compliance System (DOCS)

    National Research Council Canada - National Science Library

    Rasmussen, Steve L; Stone, Daniel A

    2005-01-01

    The Digital Opacity Compliance System (DOCS) software translates images from a commercial digital camera into visual plume opacity measurements, and is proposed as an alternate reporting method to EPA Method 9...

  10. 78 FR 22540 - Notice of Public Meeting/Webinar: EPA Method Development Update on Drinking Water Testing Methods...

    Science.gov (United States)

    2013-04-16

    .... Environmental Protection Agency (EPA) Office of Ground Water and Drinking Water, Standards and Risk Management.../fem/agency_methods.htm . USEPA. 2009. Method Validation of U.S. Environmental Protection Agency... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OW-2013-0213; FRL-9803-5] Notice of Public Meeting/Webinar...

  11. Antimicrobial Testing Methods & Procedures Developed by EPA's Microbiology Laboratory

    Science.gov (United States)

    We develop antimicrobial testing methods and standard operating procedures to measure the effectiveness of hard surface disinfectants against a variety of microorganisms. Find methods and procedures for antimicrobial testing.

  12. EPA Method 245.2: Mercury (Automated Cold Vapor Technique)

    Science.gov (United States)

    Method 245.2 describes procedures for preparation and analysis of drinking water samples for analysis of mercury using acid digestion and cold vapor atomic absorption. Samples are prepared using an acid digestion technique.

  13. Project-Based Learning in Undergraduate Environmental Chemistry Laboratory: Using EPA Methods to Guide Student Method Development for Pesticide Quantitation

    Science.gov (United States)

    Davis, Eric J.; Pauls, Steve; Dick, Jonathan

    2017-01-01

    Presented is a project-based learning (PBL) laboratory approach for an upper-division environmental chemistry or quantitative analysis course. In this work, a combined laboratory class of 11 environmental chemistry students developed a method based on published EPA methods for the extraction of dichlorodiphenyltrichloroethane (DDT) and its…

  14. 40 CFR 53.16 - Supersession of reference methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Supersession of reference methods. 53... (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS General Provisions § 53.16 Supersession of reference methods. (a) This section prescribes procedures and criteria applicable to requests that...

  15. Laboratory testing of geomembrane for waste containment EPA Method 9090, March 1995. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Whitlock, R.W. [Westinghouse Hanford Co., Richland, WA (United States)

    1995-05-15

    This report describes the work performed by TRI/Environmental, Inc. (TRI) to determine the chemical compatibility of one geomembrane and one seamed geomembrane with four synthetically generated leachates. The objective was to determine the resistance of the geomembrane to changes caused by exposure to the leachates. Changes in physical and mechanical properties were measured after exposure to the leachates at 23 C and 50 C for 30, 60, 90 and 120 days. Exposures were performed in accordance with the exposure regimen specified in US Environmental Protection Agency (EPA) Method 9090A. Methods, results and discussion are provided. Test results are also provided in the Tables of Results which accompany this report.

  16. 77 FR 32632 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of Three New Equivalent Methods

    Science.gov (United States)

    2012-06-01

    ... Methods: Designation of Three New Equivalent Methods AGENCY: Environmental Protection Agency. ACTION... accordance with 40 CFR Part 53, three new equivalent methods: One for measuring concentrations of nitrogen... INFORMATION: In accordance with regulations at 40 CFR Part 53, the EPA evaluates various methods for...

  17. 78 FR 67360 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of Five New Equivalent Methods

    Science.gov (United States)

    2013-11-12

    ... Methods: Designation of Five New Equivalent Methods AGENCY: Office of Research and Development; Environmental Protection Agency (EPA). ACTION: Notice of the designation of five new equivalent methods for...) has designated, in accordance with 40 CFR Part 53, five new equivalent methods, one for measuring...

  18. Optimization of One-Step In Situ Transesterification Method for Accurate Quantification of EPA in Nannochloropsis gaditana

    Directory of Open Access Journals (Sweden)

    Yuting Tang

    2016-11-01

    Full Text Available Microalgae are a valuable source of lipid feedstocks for biodiesel and valuable omega-3 fatty acids. Nannochloropsis gaditana has emerged as a promising producer of eicosapentaenoic acid (EPA due to its fast growth rate and high EPA content. In the present study, the fatty acid profile of Nannochloropsis gaditana was found to be naturally high in EPA and devoid of docosahexaenoic acid (DHA, thereby providing an opportunity to maximize the efficacy of EPA production. Using an optimized one-step in situ transesterification method (methanol:biomass = 90 mL/g; HCl 5% by vol.; 70 °C; 1.5 h, the maximum fatty acid methyl ester (FAME yield of Nannochloropsis gaditana cultivated under rich condition was quantified as 10.04% ± 0.08% by weight with EPA-yields as high as 4.02% ± 0.17% based on dry biomass. The total FAME and EPA yields were 1.58- and 1.23-fold higher separately than that obtained using conventional two-step method (solvent system: methanol and chloroform. This one-step in situ method provides a fast and simple method to measure fatty acid methyl ester (FAME yields and could serve as a promising method to generate eicosapentaenoic acid methyl ester from microalgae.

  19. EPA (Environmental Protection Agency) Method Study 12, cyanide in water. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Winter, J.; Britton, P.; Kroner, R.

    1984-05-01

    EPA Method Study 12, Cyanide in Water reports the results of a study by EMSL-Cincinnati for the parameters, Total Cyanide and Cyanides Amendable to Chlorination, present in water at microgram per liter levels. Four methods: pyridine-pyrazolone, pyridine-barbituric acid, electrode and Roberts-Jackson were used by 112 laboratories in Federal and State agencies, municipalities, universities, and the private/industrial sector. Sample concentrates were prepared in pairs with similar concentrations at each of three levels. Analysts diluted samples to volume with distilled and natural waters and analyzed them. Precision, accuracy, bias and the natural water interference were evaluated for each analytical method and comparisons were made between the four methods.

  20. Environmental reference materials methods and case studies

    DEFF Research Database (Denmark)

    Schramm-Nielsen, Karina Edith

    1998-01-01

    . This study lasted 22 months as well. The samples were produced and stored according to a 2³ factorial design. The influences of storage temperature, UV radiation and ultra-filtration on the stability of NH4-N and total phosphorous have been investigated. A Youden plot method is suggested for the graphical....... The methods have been evaluated with regard to their robustness towards variations in the chemical analytical method and with regard to the number of times a significant out of control situation is indicated. The second study regards the stability of NH4-N and total phosphorous in autoclaved seawater samples...... with wastewater. The purpose was to improve ortho-phosphate (and total phosphorous) homogeneity. A procedure is suggested which includes freeze-drying and redissolving. All calculations have been performed in SAS® primarily by means of elementary procedures, analyses of variance procedures, SAS Insight and SAS...

  1. Reference depth for geostrophic computation - A new method

    Digital Repository Service at National Institute of Oceanography (India)

    Varkey, M.J.; Sastry, J.S.

    Various methods are available for the determination of reference depth for geostrophic computation. A new method based on the vertical profiles of mean and variance of the differences of mean specific volume anomaly (delta x 10) for different layers...

  2. Indirect methods for reference interval determination - review and recommendations.

    Science.gov (United States)

    Jones, Graham R D; Haeckel, Rainer; Loh, Tze Ping; Sikaris, Ken; Streichert, Thomas; Katayev, Alex; Barth, Julian H; Ozarda, Yesim

    2018-04-19

    Reference intervals are a vital part of the information supplied by clinical laboratories to support interpretation of numerical pathology results such as are produced in clinical chemistry and hematology laboratories. The traditional method for establishing reference intervals, known as the direct approach, is based on collecting samples from members of a preselected reference population, making the measurements and then determining the intervals. An alternative approach is to perform analysis of results generated as part of routine pathology testing and using appropriate statistical techniques to determine reference intervals. This is known as the indirect approach. This paper from a working group of the International Federation of Clinical Chemistry (IFCC) Committee on Reference Intervals and Decision Limits (C-RIDL) aims to summarize current thinking on indirect approaches to reference intervals. The indirect approach has some major potential advantages compared with direct methods. The processes are faster, cheaper and do not involve patient inconvenience, discomfort or the risks associated with generating new patient health information. Indirect methods also use the same preanalytical and analytical techniques used for patient management and can provide very large numbers for assessment. Limitations to the indirect methods include possible effects of diseased subpopulations on the derived interval. The IFCC C-RIDL aims to encourage the use of indirect methods to establish and verify reference intervals, to promote publication of such intervals with clear explanation of the process used and also to support the development of improved statistical techniques for these studies.

  3. Reference interval computation: which method (not) to choose?

    Science.gov (United States)

    Pavlov, Igor Y; Wilson, Andrew R; Delgado, Julio C

    2012-07-11

    When different methods are applied to reference interval (RI) calculation the results can sometimes be substantially different, especially for small reference groups. If there are no reliable RI data available, there is no way to confirm which method generates results closest to the true RI. We randomly drawn samples obtained from a public database for 33 markers. For each sample, RIs were calculated by bootstrapping, parametric, and Box-Cox transformed parametric methods. Results were compared to the values of the population RI. For approximately half of the 33 markers, results of all 3 methods were within 3% of the true reference value. For other markers, parametric results were either unavailable or deviated considerably from the true values. The transformed parametric method was more accurate than bootstrapping for sample size of 60, very close to bootstrapping for sample size 120, but in some cases unavailable. We recommend against using parametric calculations to determine RIs. The transformed parametric method utilizing Box-Cox transformation would be preferable way of RI calculation, if it satisfies normality test. If not, the bootstrapping is always available, and is almost as accurate and precise as the transformed parametric method. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. MOISTURE IN COTTON BY THE KARL FISCHER TITRATION REFERENCE METHOD

    Science.gov (United States)

    Moisture is a critical parameter that influences many aspects of cotton fiber from harvesting and ginning to various fiber properties. Because of their importance, reference moisture methods that are more accurate than the existing oven-drying techniques and relatively easy to generate results are ...

  5. Development and Evaluation of EPA Method 1615 for Detection of Enterovirus and Norovirus in Water

    Science.gov (United States)

    The U.S. EPA developed a sample concentration and preparation assay in conjunction with the Total Culturable Virus Assay for concentrating and measuring culturable viruses in source and drinking waters as part of the Information Collection Rule promulgated in 1996. In an effort...

  6. VALIDATION OF EPA METHOD 1682: SALMONELLA IN BIOSOLIDS BY MODIFIED, SEMISOLID RAPPAPORT-VASSILIADIS (MSRV) MEDIUM

    Science.gov (United States)

    Treated biosolids may be applied to land as a crop nutrient and soil conditioner. However, land application of biosolids may pose the risk of releasing pathogens into the environment if disinfection and use criteria established by EPA at 40 CFR part 503 are not met. Among these c...

  7. Certified reference materials and reference methods for nuclear safeguards and security.

    Science.gov (United States)

    Jakopič, R; Sturm, M; Kraiem, M; Richter, S; Aregbe, Y

    2013-11-01

    Confidence in comparability and reliability of measurement results in nuclear material and environmental sample analysis are established via certified reference materials (CRMs), reference measurements, and inter-laboratory comparisons (ILCs). Increased needs for quality control tools in proliferation resistance, environmental sample analysis, development of measurement capabilities over the years and progress in modern analytical techniques are the main reasons for the development of new reference materials and reference methods for nuclear safeguards and security. The Institute for Reference Materials and Measurements (IRMM) prepares and certifices large quantities of the so-called "large-sized dried" (LSD) spikes for accurate measurement of the uranium and plutonium content in dissolved nuclear fuel solutions by isotope dilution mass spectrometry (IDMS) and also develops particle reference materials applied for the detection of nuclear signatures in environmental samples. IRMM is currently replacing some of its exhausted stocks of CRMs with new ones whose specifications are up-to-date and tailored for the demands of modern analytical techniques. Some of the existing materials will be re-measured to improve the uncertainties associated with their certified values, and to enable laboratories to reduce their combined measurement uncertainty. Safeguards involve the quantitative verification by independent measurements so that no nuclear material is diverted from its intended peaceful use. Safeguards authorities pay particular attention to plutonium and the uranium isotope (235)U, indicating the so-called 'enrichment', in nuclear material and in environmental samples. In addition to the verification of the major ratios, n((235)U)/n((238)U) and n((240)Pu)/n((239)Pu), the minor ratios of the less abundant uranium and plutonium isotopes contain valuable information about the origin and the 'history' of material used for commercial or possibly clandestine purposes, and

  8. Dual reference point temperature interrogating method for distributed temperature sensor

    International Nuclear Information System (INIS)

    Ma, Xin; Ju, Fang; Chang, Jun; Wang, Weijie; Wang, Zongliang

    2013-01-01

    A novel method based on dual temperature reference points is presented to interrogate the temperature in a distributed temperature sensing (DTS) system. This new method is suitable to overcome deficiencies due to the impact of DC offsets and the gain difference in the two signal channels of the sensing system during temperature interrogation. Moreover, this method can in most cases avoid the need to calibrate the gain and DC offsets in the receiver, data acquisition and conversion. An improved temperature interrogation formula is presented and the experimental results show that this method can efficiently estimate the channel amplification and system DC offset, thus improving the system accuracy. (letter)

  9. Method of evaluation of diagnostics reference levels in computerized tomography

    International Nuclear Information System (INIS)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  10. Standardization of enterococci density estimates by EPA qPCR methods and comparison of beach action value exceedances in river waters with culture methods

    Science.gov (United States)

    The U.S.EPA has published recommendations for calibrator cell equivalent (CCE) densities of enterococci in recreational waters determined by a qPCR method in its 2012 Recreational Water Quality Criteria (RWQC). The CCE quantification unit stems from the calibration model used to ...

  11. Reference neutron radiations. Part 1: Characteristics and methods of production

    International Nuclear Information System (INIS)

    2001-01-01

    ISO 8529 consists of the following parts, under the general title Reference neutron radiations: Part 1: Characteristics and methods of production; Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field; Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence. This Part 1. of ISO 8529 specifies the reference neutron radiations, in the energy range from thermal up to 20 MeV, for calibrating neutron-measuring devices used for radiation protection purposes and for determining their response as a function of neutron energy. Reference radiations are given for neutron fluence rates of up to 1x10 9 m 2 s-1 , corresponding, at a neutron energy of 1 MeV, to dose-equivalent rates of up to 100 mSv h -1 . This part of ISO 8529 is concerned only with the methods of producing and characterizing the neutron reference radiations. The procedures for applying these radiations for calibrations are described in ISO 8529-2 and ISO 8529-3. The reference radiations specified are the following: neutrons from radionuclide sources, including neutrons from sources in a moderator; neutrons produced by nuclear reactions with charged particles from accelerators; neutrons from reactors. In view of the methods of production and use of them, these reference radiations are divided, for the purposes of this part of ISO 8529, into the following two separate sections. In clause 4, radionuclide neutron sources with wide spectra are specified for the calibration of neutron measuring devices. These sources should be used by laboratories engaged in the routine calibration of neutron-measuring devices, the particular design of which has already been type tested. In clause 5, accelerator-produced monoenergetic neutrons and reactor-produced neutrons with wide or quasi monoenergetic spectra are specified for determining the response of neutron-measuring devices

  12. Towards Automatic Testing of Reference Point Based Interactive Methods

    OpenAIRE

    Ojalehto, Vesa; Podkopaev, Dmitry; Miettinen, Kaisa

    2016-01-01

    In order to understand strengths and weaknesses of optimization algorithms, it is important to have access to different types of test problems, well defined performance indicators and analysis tools. Such tools are widely available for testing evolutionary multiobjective optimization algorithms. To our knowledge, there do not exist tools for analyzing the performance of interactive multiobjective optimization methods based on the reference point approach to communicating ...

  13. One directional polarized neutron reflectometry with optimized reference layer method

    International Nuclear Information System (INIS)

    Masoudi, S. Farhad; Jahromi, Saeed S.

    2012-01-01

    In the past decade, several neutron reflectometry methods for determining the modulus and phase of the complex reflection coefficient of an unknown multilayer thin film have been worked out among which the method of variation of surroundings and reference layers are of highest interest. These methods were later modified for measurement of the polarization of the reflected beam instead of the measurement of the intensities. In their new architecture, these methods not only suffered from the necessity of change of experimental setup but also another difficulty was added to their experimental implementations. This deficiency was related to the limitations of the technology of the neutron reflectometers that could only measure the polarization of the reflected neutrons in the same direction as the polarization of the incident beam. As the instruments are limited, the theory has to be optimized so that the experiment could be performed. In a recent work, we developed the method of variation of surroundings for one directional polarization analysis. In this new work, the method of reference layer with polarization analysis has been optimized to determine the phase and modulus of the unknown film with measurement of the polarization of the reflected neutrons in the same direction as the polarization of the incident beam.

  14. Phthalate exposure, even below US EPA reference doses, was associated with semen quality and reproductive hormones: Prospective MARHCS study in general population.

    Science.gov (United States)

    Chen, Qing; Yang, Huan; Zhou, Niya; Sun, Lei; Bao, Huaqiong; Tan, Lu; Chen, Hongqiang; Ling, Xi; Zhang, Guowei; Huang, Linping; Li, Lianbing; Ma, Mingfu; Yang, Hao; Wang, Xiaogang; Zou, Peng; Peng, Kaige; Liu, Taixiu; Shi, Xiefei; Feng, Dejian; Zhou, Ziyuan; Ao, Lin; Cui, Zhihong; Cao, Jia

    2017-07-01

    Environment-Protection-Agency Reference Doses (EPA RfDs) for phthalate intakes are based on limited evidence, especially regarding low-dose male-reproductive toxicity. This study investigates the association between phthalate exposure and semen parameters and reproductive hormones in a general population with low phthalate exposure compared to the EPA RfDs. The MARHCS (Male-Reproductive-Health-in-Chongqing-College-Students) cohort recruited 796 male students, who experienced a relocation of campuses and shifting environmental exposure. Urine, semen and blood before and after the relocation was collected and investigated for: (1) the associations between 13 urinary phthalate metabolites and 11 semen/hormone outcomes (five semen parameters including semen volume, sperm concentration, total sperm number, progressive motility, normal morphology) and six serum reproductive hormones including estradiol, follicle-stimulating hormone, luteinizing hormone, prolactin, progesterone, testosterone; (2) re-analysis of the metabolite-outcome associations in the subjects with estimated phthalate intakes below the RfDs; (3) a change in phthalate metabolites and change in semen/hormone outcomes after the relocation; (4) the association between these changes. (1) All but two semen/hormone outcomes were associated with at least one phthalate metabolite, e.g., each quartile monoethyl phthalate was associated with a 5.3%, 5.7% and 2.6% decrease of sperm concentration, total sperm number and progressive motility respectively. (2) In the subjects with phthalate intakes below the RfDs, these metabolite-outcome associations remained significant. (3) All metabolites except mono(2-ethylhexyl) phthalate declined after relocation (Phormone increased (by 5.9%, 25.0%, 34.2% and 10.0%) and testosterone decreased (by 7.0%). (4) The changes in semen volume, normal morphology, estradiol and testosterone, but not the change in luteinizing hormone after relocation, were associated with the changes in

  15. Summary of EPA's risk assessment results from the analysis of alternative methods of low-level waste disposal

    International Nuclear Information System (INIS)

    Bandrowski, M.S.; Hung, C.Y.; Meyer, G.L.; Rogers, V.C.

    1987-01-01

    Evaluation of the potential health risk and individual exposure from a broad number of disposal alternatives is an important part of EPA's program to develop generally applicable environmental standards for the land disposal of low-level radioactive wastes (LLW). The Agency has completed an analysis of the potential population health risks and maximum individual exposures from ten disposal methods under three different hydrogeological and climatic settings. This paper briefly describes the general input and analysis procedures used in the risk assessment for LLW disposal and presents their preliminary results. Some important lessons learned from simulating LLW disposal under a large variety of methods and conditions are identified

  16. A Modified EPA Method 1623 that Uses Tangential Flow Hollow-Fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidum and Giardia spp.

    Science.gov (United States)

    This protocol describes the use of a tangential flow hollow-fiber ultrafiltration sample concentration system and a heat dissociation as alternative steps for the detection of waterborne Cryptosporidium and Giardia species using EPA Method 1623.

  17. Methods to estimate irrigated reference crop evapotranspiration - a review.

    Science.gov (United States)

    Kumar, R; Jat, M K; Shankar, V

    2012-01-01

    Efficient water management of crops requires accurate irrigation scheduling which, in turn, requires the accurate measurement of crop water requirement. Irrigation is applied to replenish depleted moisture for optimum plant growth. Reference evapotranspiration plays an important role for the determination of water requirements for crops and irrigation scheduling. Various models/approaches varying from empirical to physically base distributed are available for the estimation of reference evapotranspiration. Mathematical models are useful tools to estimate the evapotranspiration and water requirement of crops, which is essential information required to design or choose best water management practices. In this paper the most commonly used models/approaches, which are suitable for the estimation of daily water requirement for agricultural crops grown in different agro-climatic regions, are reviewed. Further, an effort has been made to compare the accuracy of various widely used methods under different climatic conditions.

  18. Comparison of the reference mark azimuth determination methods

    Directory of Open Access Journals (Sweden)

    Danijel Šugar

    2013-03-01

    Full Text Available The knowledge of the azimuth of the reference mark is of crucial importance in the determination of the declination which is defined as the ellipsoidal (geodetic azimuth of the geomagnetic meridian. The accuracy of the azimuth determination has direct impact on the accuracy of the declination. The orientation of the Declination-Inclination Magnetometer is usually carried out by sighting the reference mark in two telescope faces in order to improve the reliability of the observations and eliminate some instrumental errors. In this paper, different coordinate as well as azimuth determination methods using GNSS (Global Navigation Satellite System observation techniques within VPPS (High-Precision Positioning Service and GPPS (Geodetic-Precision Positioning Service services of the CROPOS (CROatian POsitioning System system were explained. The azimuth determination by the observation of the Polaris was exposed and it was subsequently compared with the observation of the Sun using hour-angle and zenith-distance method. The procedure of the calculation of the geodetic azimuth from the astronomic azimuth was explained. The azimuth results obtained by different methods were compared and the recommendations on the minimal distance between repeat station and azimuth mark were given. The results shown in this paper were based on the observations taken on the POKU_SV repeat station.

  19. Introduction to benchmark dose methods and U.S. EPA's benchmark dose software (BMDS) version 2.1.1

    International Nuclear Information System (INIS)

    Davis, J. Allen; Gift, Jeffrey S.; Zhao, Q. Jay

    2011-01-01

    Traditionally, the No-Observed-Adverse-Effect-Level (NOAEL) approach has been used to determine the point of departure (POD) from animal toxicology data for use in human health risk assessments. However, this approach is subject to substantial limitations that have been well defined, such as strict dependence on the dose selection, dose spacing, and sample size of the study from which the critical effect has been identified. Also, the NOAEL approach fails to take into consideration the shape of the dose-response curve and other related information. The benchmark dose (BMD) method, originally proposed as an alternative to the NOAEL methodology in the 1980s, addresses many of the limitations of the NOAEL method. It is less dependent on dose selection and spacing, and it takes into account the shape of the dose-response curve. In addition, the estimation of a BMD 95% lower bound confidence limit (BMDL) results in a POD that appropriately accounts for study quality (i.e., sample size). With the recent advent of user-friendly BMD software programs, including the U.S. Environmental Protection Agency's (U.S. EPA) Benchmark Dose Software (BMDS), BMD has become the method of choice for many health organizations world-wide. This paper discusses the BMD methods and corresponding software (i.e., BMDS version 2.1.1) that have been developed by the U.S. EPA, and includes a comparison with recently released European Food Safety Authority (EFSA) BMD guidance.

  20. Generating method-specific Reference Ranges - A harmonious outcome?

    Science.gov (United States)

    Lee, Graham R; Griffin, Alison; Halton, Kieran; Fitzgibbon, Maria C

    2017-12-01

    When laboratory Reference Ranges (RR) do not reflect analytical methodology, result interpretation can cause misclassification of patients and inappropriate management. This can be mitigated by determining and implementing method-specific RRs, which was the main objective of this study. Serum was obtained from healthy volunteers (Male + Female, n > 120) attending hospital health-check sessions during June and July 2011. Pseudo-anonymised aliquots were stored (at - 70 °C) prior t° analysis on Abbott ARCHITECT c16000 chemistry and i 2000SR immunoassay analysers. Data were stratified by gender where appropriate. Outliers were excluded statistically (Tukey method) to generate non-parametric RRs (2.5th + 97.5th percentiles). RRs were compared to those quoted by Abbott and UK Pathology Harmony (PH) where possible. For 7 selected tests, RRs were verified using a data mining approach. For chemistry tests (n = 23), Upper or Lower Reference Limits (LRL or URL) were > 20% different from Abbott ranges in 25% of tests (11% from PH ranges) but in 38% for immunoassay tests (n = 13). RRs (mmol/L) for sodium (138-144), potassium (3.8-4.9) and chloride (102-110) were considerably narrower than PH ranges (133-146, 3.5-5.0 and 95-108, respectively). The gender difference for ferritin (M: 29-441, F: 8-193 ng/mL) was more pronounced than reported by Abbott (M: 22-275, F: 5-204 ng/mL). Verification studies showed good agreement for chemistry tests (mean [SD] difference = 0.4% [1.2%]) but less so for immunoassay tests (27% [29%]), particularly for TSH (LRL). Where resource permits, we advocate using method-specific RRs in preference to other sources, particularly where method bias and lack of standardisation limits RR transferability and harmonisation.

  1. Striking against bioterrorism with advanced proteomics and reference methods.

    Science.gov (United States)

    Armengaud, Jean

    2017-01-01

    The intentional use by terrorists of biological toxins as weapons has been of great concern for many years. Among the numerous toxins produced by plants, animals, algae, fungi, and bacteria, ricin is one of the most scrutinized by the media because it has already been used in biocrimes and acts of bioterrorism. Improving the analytical toolbox of national authorities to monitor these potential bioweapons all at once is of the utmost interest. MS/MS allows their absolute quantitation and exhibits advantageous sensitivity, discriminative power, multiplexing possibilities, and speed. In this issue of Proteomics, Gilquin et al. (Proteomics 2017, 17, 1600357) present a robust multiplex assay to quantify a set of eight toxins in the presence of a complex food matrix. This MS/MS reference method is based on scheduled SRM and high-quality standards consisting of isotopically labeled versions of these toxins. Their results demonstrate robust reliability based on rather loose scheduling of SRM transitions and good sensitivity for the eight toxins, lower than their oral median lethal doses. In the face of an increased threat from terrorism, relevant reference assays based on advanced proteomics and high-quality companion toxin standards are reliable and firm answers. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Marine Biotoxins: Occurrence, Toxicity, Regulatory Limits and Reference Methods

    Directory of Open Access Journals (Sweden)

    Pierina Visciano

    2016-07-01

    Full Text Available Harmful algal blooms are natural phenomena caused by the massive growth of phytoplankton that may contain highly toxic chemicals, the so-called marine biotoxins causing illness and even death to both aquatic organisms and humans. Their occurrence has been increased in frequency and severity, suggesting a worldwide public health risk. Marine biotoxins can accumulate in bivalve molluscs and regulatory limits have been set for some classes according to European Union legislation. These compounds can be distinguished in water- and fat-soluble molecules. The first group involves those of Paralytic Shellfish Poisoning and Amnesic Shellfish Poisoning, whereas the toxins soluble in fat can cause Diarrheic Shellfish Poisoning and Neurotoxic Shellfish Poisoning. Due to the lack of long-term toxicity studies, establishing tolerable daily intakes for any of these marine biotoxins was not possible, but an acute reference dose can be considered more appropriate, because these molecules show an acute toxicity. Dietary exposure assessment is linked both to the levels of marine biotoxins present in bivalve molluscs and the portion that could be eaten by consumers. Symptoms may vary from a severe gastrointestinal intoxication with diarrhea, nausea, vomiting, and abdominal cramps to neurological disorders such as ataxia, dizziness, partial paralysis, and respiratory distress. The official method for the detection of marine biotoxins is the mouse bioassay (MBA showing some limits due to ethical restrictions and insufficient specificity. For this reason, the liquid chromatography–mass spectrometry method has replaced MBA as the reference technique. However, the monitoring of algal blooms producing marine biotoxins should be regularly assessed in order to obtain more reliable, accurate estimates of bloom toxicity and their potential impacts.

  3. Standard Test Method for Calibration of Non-Concentrator Photovoltaic Secondary Reference Cells

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers calibration and characterization of secondary terrestrial photovoltaic reference cells to a desired reference spectral irradiance distribution. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of a photovoltaic device. 1.2 Secondary reference cells are calibrated indoors using simulated sunlight or outdoors in natural sunlight by reference to a primary reference cell previously calibrated to the same desired reference spectral irradiance distribution. 1.3 Secondary reference cells calibrated according to this test method will have the same radiometric traceability as the of the primary reference cell used for the calibration. Therefore, if the primary reference cell is traceable to the World Radiometric Reference (WRR, see Test Method E816), the resulting secondary reference cell will also be traceable to the WRR. 1.4 This test method appli...

  4. LA-ICP-MS of magnetite: Methods and reference materials

    Science.gov (United States)

    Nadoll, P.; Koenig, A.E.

    2011-01-01

    Magnetite (Fe3O4) is a common accessory mineral in many geologic settings. Its variable geochemistry makes it a powerful petrogenetic indicator. Electron microprobe (EMPA) analyses are commonly used to examine major and minor element contents in magnetite. Laser ablation ICP-MS (LA-ICP-MS) is applicable to trace element analyses of magnetite but has not been widely employed to examine compositional variations. We tested the applicability of the NIST SRM 610, the USGS GSE-1G, and the NIST SRM 2782 reference materials (RMs) as external standards and developed a reliable method for LA-ICP-MS analysis of magnetite. LA-ICP-MS analyses were carried out on well characterized magnetite samples with a 193 nm, Excimer, ArF LA system. Although matrix-matched RMs are sometimes important for calibration and normalization of LA-ICP-MS data, we demonstrate that glass RMs can produce accurate results for LA-ICP-MS analyses of magnetite. Cross-comparison between the NIST SRM 610 and USGS GSE-1G indicates good agreement for magnetite minor and trace element data calibrated with either of these RMs. Many elements show a sufficiently good match between the LA-ICP-MS and the EMPA data; for example, Ti and V show a close to linear relationship with correlation coefficients, R2 of 0.79 and 0.85 respectively. ?? 2011 The Royal Society of Chemistry.

  5. New reference materials improvement of methods of measurements

    International Nuclear Information System (INIS)

    Marchandise, H.

    1985-01-01

    The report summarizes the development of about 120 reference materials in a variety of fields (non ferrous metals, trace element analysis, food products, biomedical analysis, physical and technical properties of solid materials). The document also provides practical advice for trace element analyses, describes the principles followed for certifying reference materials and provides recommendations for their use

  6. EPA Method 614: The Determination of Organophosphorus Pesticides in Municipal and Industrial Wastewater

    Science.gov (United States)

    Method 614 describes procedures for preparation and analysis of samples for determination of organophosphate pesticides in industrial and municipal discharges using a GC with a phosphorus-specific flame photometric detector (FPD).

  7. Methods for Estimating the Social Benefits of EPA Land Cleanup and Reuse Programs (2007)

    Science.gov (United States)

    The Office of Policy, Economics and Innovation’s National Center for Environmental Economics, and the Office of Solid Waste and Emergency Response’s Land Revitalization Office convened a workshop on risk assessment and benefit estimation methods in 2006.

  8. The Organic Food Method and Movement: An Interdisciplinary Reference Review

    Science.gov (United States)

    Park, Elizabeth E.

    2011-01-01

    From popular movies to New York Times bestsellers, organic food is widely acknowledged to be of growing importance. Many community college students are asking: How is organic food different from everything else in the grocery store? What impact does farming have on the environment? How safe is our food? A survey of reference works introduces…

  9. EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. Part III. Virus Detection by RT-qPCR

    Science.gov (United States)

    EPA Method 1615 measures enteroviruses and noroviruses present in environmental and drinking waters. The viral ribonucleic acid (RNA) from water sample concentrates is extracted and tested for enterovirus and norovirus RNA using reverse transcription-quantitative PCR (RT-qPCR). V...

  10. Reference Values for Spirometry Derived Using Lambda, Mu, Sigma (LMS) Method in Korean Adults: in Comparison with Previous References.

    Science.gov (United States)

    Jo, Bum Seak; Myong, Jun Pyo; Rhee, Chin Kook; Yoon, Hyoung Kyu; Koo, Jung Wan; Kim, Hyoung Ryoul

    2018-01-15

    The present study aimed to update the prediction equations for spirometry and their lower limits of normal (LLN) by using the lambda, mu, sigma (LMS) method and to compare the outcomes with the values of previous spirometric reference equations. Spirometric data of 10,249 healthy non-smokers (8,776 females) were extracted from the fourth and fifth versions of the Korea National Health and Nutrition Examination Survey (KNHANES IV, 2007-2009; V, 2010-2012). Reference equations were derived using the LMS method which allows modeling skewness (lambda [L]), mean (mu [M]), and coefficient of variation (sigma [S]). The outcome equations were compared with previous reference values. Prediction equations were presented in the following form: predicted value = e{a + b × ln(height) + c × ln(age) + M - spline}. The new predicted values for spirometry and their LLN derived using the LMS method were shown to more accurately reflect transitions in pulmonary function in young adults than previous prediction equations derived using conventional regression analysis in 2013. There were partial discrepancies between the new reference values and the reference values from the Global Lung Function Initiative in 2012. The results should be interpreted with caution for young adults and elderly males, particularly in terms of the LLN for forced expiratory volume in one second/forced vital capacity in elderly males. Serial spirometry follow-up, together with correlations with other clinical findings, should be emphasized in evaluating the pulmonary function of individuals. Future studies are needed to improve the accuracy of reference data and to develop continuous reference values for spirometry across all ages. © 2018 The Korean Academy of Medical Sciences.

  11. Radon and radon daughter measurements and methods utilized by EPA's Eastern Environmental Radiation Facility

    International Nuclear Information System (INIS)

    Phillips, C.R.

    1977-01-01

    The Eastern Environmental Radiation Facility (EERF), Office of Radiation Programs, has the responsibility for conducting the Environmental Protection Agency's study of the radiological impact of the phosphate industry. Numerous measurements in structures constructed on land reclaimed from phosphate mining showed that working levels in these structures range from 0.001 to 0.9 WL. Sampling is performed by drawing air through a 0.8 micrometer pore size, 25 mm diameter filter at a flow rate of 10 to 15 liters/minute for from 5 to 20 minutes, depending on the daughter levels anticipated. The detection system consists of a ruggedized silicon surface barrier detector (450 mm 2 -100 micrometer depletion) connected through an appropriate pre-amplifier-amplifier to a 1024-channel multichannel analyzer. Other measurement methods are also discussed

  12. Reference material for trace analysis by radioanalytical methods: Bowen's Kale

    International Nuclear Information System (INIS)

    Wainerdi, R.E.

    1979-01-01

    A fairly large volume of published data on 'Bowen's Kale' has been examined critically in order to develop recommendations for the use of this preparation as a 'reference material' in the standardisation and evaluation of the reliability of analytical procedures. Values are now recommended for the contents of twelve elements present in major to trace concentrations in 'Bowen's Kale'. 'Indicated values' for another 16 elements are provided. Values for 15 more elements are listed with no recommendation. The criteria adopted in categorising elements into these groups are discussed. (author)

  13. Analysis of cascade impactor and EPA method 29 data from the americium/curium pilot melter system

    International Nuclear Information System (INIS)

    Zamecnik, J.R.

    1997-11-01

    The offgas system of the Am/Cm pilot melter at TNX was characterized by measuring the particulate evolution using a cascade impactor and EPA Method 29. This sampling work was performed by John Harden of the Clemson Environmental Technologies Laboratory, under SCUREF Task SC0056. Elemental analyses were performed by the SRTC Mobile Laboratory.Operation of the Am/Cm melter with B2000 frit has resulted in deposition of PbO and boron compounds in the offgas system that has contributed to pluggage of the High Efficiency Mist Eliminator (HEME). Sampling of the offgas system was performed to quantify the amount of particulate in the offgas system under several sets of conditions. Particulate concentration and particle size distribution were measured just downstream of the melter pressure control air addition port and at the HEME inlet. At both locations, the particulate was measured with and without steam to the film cooler while the melter was idled at about 1450 degrees Celsius. Additional determinations were made at the melter location during feeding and during idling at 1150 degrees Celsius rather than 1450 degrees Celsius (both with no steam to the film cooler). Deposition of particulates upstream of the melter sample point may have, and most likely did occur in each run, so the particulate concentrations measured do no necessarily reflect the total particulate emission at the melt surface. However, the data may be used in a relative sense to judge the system performance

  14. GTX Reference Vehicle Structural Verification Methods and Weight Summary

    Science.gov (United States)

    Hunter, J. E.; McCurdy, D. R.; Dunn, P. W.

    2002-01-01

    The design of a single-stage-to-orbit air breathing propulsion system requires the simultaneous development of a reference launch vehicle in order to achieve the optimal mission performance. Accordingly, for the GTX study a 300-lb payload reference vehicle was preliminarily sized to a gross liftoff weight (GLOW) of 238,000 lb. A finite element model of the integrated vehicle/propulsion system was subjected to the trajectory environment and subsequently optimized for structural efficiency. This study involved the development of aerodynamic loads mapped to finite element models of the integrated system in order to assess vehicle margins of safety. Commercially available analysis codes were used in the process along with some internally developed spreadsheets and FORTRAN codes specific to the GTX geometry for mapping of thermal and pressure loads. A mass fraction of 0.20 for the integrated system dry weight has been the driver for a vehicle design consisting of state-of-the-art composite materials in order to meet the rigid weight requirements. This paper summarizes the methodology used for preliminary analyses and presents the current status of the weight optimization for the structural components of the integrated system.

  15. Reference satellite selection method for GNSS high-precision relative positioning

    Directory of Open Access Journals (Sweden)

    Xiao Gao

    2017-03-01

    Full Text Available Selecting the optimal reference satellite is an important component of high-precision relative positioning because the reference satellite directly influences the strength of the normal equation. The reference satellite selection methods based on elevation and positional dilution of precision (PDOP value were compared. Results show that all the above methods cannot select the optimal reference satellite. We introduce condition number of the design matrix in the reference satellite selection method to improve structure of the normal equation, because condition number can indicate the ill condition of the normal equation. The experimental results show that the new method can improve positioning accuracy and reliability in precise relative positioning.

  16. Methods to explain emission trends. From reference to realization

    International Nuclear Information System (INIS)

    Gijsen, A.; Oude Lohuis, J.

    2003-01-01

    Several methods are available to assess and determine the effects of policy measures. In this article methods to determine the effects of social and political developments on the emission of CO2 from the production of electricity in the Netherlands are discussed [nl

  17. A rule-based reference resolution method for Dutch discourse

    NARCIS (Netherlands)

    Harabagiu, S.; op den Akker, Hendrikus J.A.; Hospers, M.A.; Ferrandez, A.; Kroezen, Erna; Nijholt, Antinus; Lie, Danny

    2002-01-01

    This paper presents a knowledge-poor method for the solution of anaphoric and deictic expressions in Dutch texts. The method is developed for use in a text summarization system. Anaphora resolution plays an important role in the analysis of the original text as well as in the generation of the text

  18. A global multicenter study on reference values: 1. Assessment of methods for derivation and comparison of reference intervals.

    Science.gov (United States)

    Ichihara, Kiyoshi; Ozarda, Yesim; Barth, Julian H; Klee, George; Qiu, Ling; Erasmus, Rajiv; Borai, Anwar; Evgina, Svetlana; Ashavaid, Tester; Khan, Dilshad; Schreier, Laura; Rolle, Reynan; Shimizu, Yoshihisa; Kimura, Shogo; Kawano, Reo; Armbruster, David; Mori, Kazuo; Yadav, Binod K

    2017-04-01

    The IFCC Committee on Reference Intervals and Decision Limits coordinated a global multicenter study on reference values (RVs) to explore rational and harmonizable procedures for derivation of reference intervals (RIs) and investigate the feasibility of sharing RIs through evaluation of sources of variation of RVs on a global scale. For the common protocol, rather lenient criteria for reference individuals were adopted to facilitate harmonized recruitment with planned use of the latent abnormal values exclusion (LAVE) method. As of July 2015, 12 countries had completed their study with total recruitment of 13,386 healthy adults. 25 analytes were measured chemically and 25 immunologically. A serum panel with assigned values was measured by all laboratories. RIs were derived by parametric and nonparametric methods. The effect of LAVE methods is prominent in analytes which reflect nutritional status, inflammation and muscular exertion, indicating that inappropriate results are frequent in any country. The validity of the parametric method was confirmed by the presence of analyte-specific distribution patterns and successful Gaussian transformation using the modified Box-Cox formula in all countries. After successful alignment of RVs based on the panel test results, nearly half the analytes showed variable degrees of between-country differences. This finding, however, requires confirmation after adjusting for BMI and other sources of variation. The results are reported in the second part of this paper. The collaborative study enabled us to evaluate rational methods for deriving RIs and comparing the RVs based on real-world datasets obtained in a harmonized manner. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  19. 40 CFR 75.22 - Reference test methods.

    Science.gov (United States)

    2010-07-01

    ... tester may also opt to use the sample recovery and preparation procedures in ASTM D6784-02 (incorporated... 75.22 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... site and sample traverses. (2) Method 2 or its allowable alternatives, as provided in appendix A to...

  20. US EPA overview

    International Nuclear Information System (INIS)

    Rowe, W.D.

    1976-01-01

    EPA believes that effective and efficient solutions to problems in all radioactive waste disposal areas will require close coordination and cooperation among all agencies involved. In this regard, EPA already has participated in meetings with the Energy Research and Development Administration, the Nuclear Regulatory Commission, the Council on Environmental Quality, the U.S. Geological Survey, and the Office of Management and Budget to lay the groundwork for the development of a consolidated national radioactive waste disposal plan. The EPA program is directed first toward developing goals and requirements; and then, in cooperation with the public, industry, the States and Federal agencies, towards determining by what means these goals can be achieved for each waste management option. In addition, the program will develop criteria for determining when the goals of the waste management options have been achieved. In summary, EPA will provide fundamental environmental criteria and generally applicable environmental standards for permanent disposal of high level radwastes. Concurrently, ERDA will develop the necessary technology; and NRC will conduct necessary studies, develop waste-related regulations, and license specific sites and methods of control. Together, we will be able to manage the disposal of the Nation's radioactive waste in an environmentally adequate manner

  1. EPA Nonregulatory Nonroad Duty Cycles

    Science.gov (United States)

    EPA nonregulatory, nonroad duty cycles for equipment such as agricultural tractors, backhoe loaders,crawlers tractors, excavators, arc welding skid steer loaders, and wheel loaders. Also,test procedures, laboratory methods, and emissions for this equipmen

  2. Influence of adsorption and deproteination on potential free thyroxine reference methods

    DEFF Research Database (Denmark)

    Holm, Steen S; Andreasen, Lisbeth; Hansen, Palle Steen

    2002-01-01

    There is a need for consensus concerning reference methods to be used for calibration of commercial free-thyroxine (FT(4)) assays.......There is a need for consensus concerning reference methods to be used for calibration of commercial free-thyroxine (FT(4)) assays....

  3. EPA Administrative Enforcement Dockets

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA Administrative Enforcement Dockets database contains the electronic dockets for administrative penalty cases filed by EPA Regions and Headquarters. Visitors...

  4. Easy, fast and environmental friendly method for the simultaneous extraction of the 16 EPA PAHs using magnetic molecular imprinted polymers (mag-MIPs).

    Science.gov (United States)

    Villar-Navarro, Mercedes; Martín-Valero, María Jesús; Fernández-Torres, Rut Maria; Callejón-Mochón, Manuel; Bello-López, Miguel Ángel

    2017-02-15

    An easy and environmental friendly method, based on the use of magnetic molecular imprinted polymers (mag-MIPs) is proposed for the simultaneous extraction of the 16 U.S. EPA polycyclic aromatic hydrocarbons (PAHs) priority pollutants. The mag-MIPs based extraction protocol is simple, more sensitive and low organic solvent consuming compared to official methods and also adequate for those PAHs more retained in the particulate matter. The new proposed extraction method followed by HPLC determination has been validated and applied to different types of water samples: tap water, river water, lake water and mineral water. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. SYSTEMATIC ERROR REDUCTION: NON-TILTED REFERENCE BEAM METHOD FOR LONG TRACE PROFILER

    International Nuclear Information System (INIS)

    QIAN, S.; QIAN, K.; HONG, Y.; SENG, L.; HO, T.; TAKACS, P.

    2007-01-01

    Systematic error in the Long Trace Profiler (LTP) has become the major error source as measurement accuracy enters the nanoradian and nanometer regime. Great efforts have been made to reduce the systematic error at a number of synchrotron radiation laboratories around the world. Generally, the LTP reference beam has to be tilted away from the optical axis in order to avoid fringe overlap between the sample and reference beams. However, a tilted reference beam will result in considerable systematic error due to optical system imperfections, which is difficult to correct. Six methods of implementing a non-tilted reference beam in the LTP are introduced: (1) application of an external precision angle device to measure and remove slide pitch error without a reference beam, (2) independent slide pitch test by use of not tilted reference beam, (3) non-tilted reference test combined with tilted sample, (4) penta-prism scanning mode without a reference beam correction, (5) non-tilted reference using a second optical head, and (6) alternate switching of data acquisition between the sample and reference beams. With a non-tilted reference method, the measurement accuracy can be improved significantly. Some measurement results are presented. Systematic error in the sample beam arm is not addressed in this paper and should be treated separately

  6. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2012-01-01

    It saddens us deeply to learn of the passing away of Jean-Paul Diss who died suddenly on 7 June 2012 at his home.  A tribute can be read on the GAC-EPA site. * * * * * Information: http://gac-epa.org/ e-mail: gac-epa@gac-epa.org

  7. A New Synchronous Reference Frame-Based Method for Single-Phase Shunt Active Power Filters

    DEFF Research Database (Denmark)

    Monfared, Mohammad; Golestan, Saeed; Guerrero, Josep M.

    2013-01-01

    This paper deals with the design of a novel method in the synchronous reference frame (SRF) to extract the reference compensating current for single-phase shunt active power filters (APFs). Unlike previous works in the SRF, the proposed method has an innovative feature that it does not need...... the fictitious current signal. Frequency-independent operation, accurate reference current extraction and relatively fast transient response are other key features of the presented strategy. The effectiveness of the proposed method is investigated by means of detailed mathematical analysis. The results confirm...

  8. Improving Reference Service: The Case for Using a Continuous Quality Improvement Method.

    Science.gov (United States)

    Aluri, Rao

    1993-01-01

    Discusses the evaluation of library reference service; examines problems with past evaluations, including the lack of long-term planning and a systems perspective; and suggests a method for continuously monitoring and improving reference service using quality improvement tools such as checklists, cause and effect diagrams, Pareto charts, and…

  9. Resampling methods in Microsoft Excel® for estimating reference intervals.

    Science.gov (United States)

    Theodorsson, Elvar

    2015-01-01

    Computer-intensive resampling/bootstrap methods are feasible when calculating reference intervals from non-Gaussian or small reference samples. Microsoft Excel® in version 2010 or later includes natural functions, which lend themselves well to this purpose including recommended interpolation procedures for estimating 2.5 and 97.5 percentiles. 
The purpose of this paper is to introduce the reader to resampling estimation techniques in general and in using Microsoft Excel® 2010 for the purpose of estimating reference intervals in particular.
 Parametric methods are preferable to resampling methods when the distributions of observations in the reference samples is Gaussian or can transformed to that distribution even when the number of reference samples is less than 120. Resampling methods are appropriate when the distribution of data from the reference samples is non-Gaussian and in case the number of reference individuals and corresponding samples are in the order of 40. At least 500-1000 random samples with replacement should be taken from the results of measurement of the reference samples.

  10. 7 CFR 801.7 - Reference methods and tolerances for near-infrared spectroscopy (NIRS) analyzers.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Reference methods and tolerances for near-infrared spectroscopy (NIRS) analyzers. 801.7 Section 801.7 Agriculture Regulations of the Department of Agriculture...), DEPARTMENT OF AGRICULTURE OFFICIAL PERFORMANCE REQUIREMENTS FOR GRAIN INSPECTION EQUIPMENT § 801.7 Reference...

  11. A method to calibrate a solar pyranometer for measuring reference diffuse irradiance

    Energy Technology Data Exchange (ETDEWEB)

    Reda, I.; Stoffel, T.; Myers, D. [National Renewable Energy Laboratory, Golden, CO (United States)

    2003-02-01

    Accurate pyranometer calibrations, traceable to internationally recognized standards, are critical for solar irradiance measurements. One calibration method is the component summation, where the pyranometers are calibrated outdoors under clear sky conditions, and the reference global solar irradiance is calculated as the sum of two reference components, the diffuse and subtended beam solar irradiances. The beam component is measured with pyrheliometers traceable to the World Radiometric Reference, while there is no internationally recognized reference for the diffuse component. In the absence of such a reference, we present a method to consistently calibrate pyranometers for measuring the diffuse component with an estimated uncertainty of {+-} (3% of reading +1 W/m{sup 2}). The method is based on using a modified shade/unshade method, and pyranometers with less than 1 W/m{sup 2} thermal offset errors. We evaluated the consistency of our method by calibrating three pyranometers four times. Calibration results show that the responsivity change is within {+-} 0.52% for the three pyranometers. We also evaluated the effect of calibrating pyranometers unshaded, then using them shaded to measure diffuse irradiance. We calibrated three unshaded pyranometers using the component summation method. Their outdoor measurements of clear sky diffuse irradiance, from sunrise to sundown, showed that the three calibrated pyranometers can be used to measure the diffuse irradiance to within {+-} 1.4 W/m{sup 2} variation from the reference irradiance. (author)

  12. 75 FR 22126 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Science.gov (United States)

    2010-04-27

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9142-1] Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods: Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air...

  13. 75 FR 9894 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Science.gov (United States)

    2010-03-04

    ..., Research Triangle Park, North Carolina 27711. Designation of this new equivalent method is intended to... ENVIRONMENTAL PROTECTION AGENCY [FRL-9121-6] Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods: Designation of One New Equivalent Method AGENCY: Environmental...

  14. 76 FR 15974 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Science.gov (United States)

    2011-03-22

    ..., Research Triangle Park, North Carolina 27711. Designation of these new equivalent methods is intended to... ENVIRONMENTAL PROTECTION AGENCY [FRL-9285-2] Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods: Designation of Four New Equivalent Methods AGENCY: Environmental...

  15. 76 FR 62402 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Science.gov (United States)

    2011-10-07

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9476-7] Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods; Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air...

  16. 75 FR 51039 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Science.gov (United States)

    2010-08-18

    ..., Research Triangle Park, North Carolina 27711. Designation of these new equivalent methods is intended to... ENVIRONMENTAL PROTECTION AGENCY [FRL-9190-5] Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods: Designation of Two New Equivalent Methods AGENCY: Environmental...

  17. 75 FR 30022 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Science.gov (United States)

    2010-05-28

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9156-1] Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods: Designation of One New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of one new equivalent method for monitoring ambient air...

  18. A simple method for HPLC retention time prediction: linear calibration using two reference substances.

    Science.gov (United States)

    Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng

    2017-01-01

    Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.

  19. Comparison of Enterococcus quantitative polymerase chain reaction analysis results from midwest U.S. river samples using EPA Method 1611 and Method 1609 PCR reagents

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) has provided recommended beach advisory values in its 2012 recreational water quality criteria (RWQC) for states wishing to use quantitative polymerase chain reaction (qPCR) for the monitoring of Enterococcus fecal indicator bacteria...

  20. Effect of reference loads on fracture mechanics analysis of surface cracked pipe based on reference stress method

    International Nuclear Information System (INIS)

    Shim, Do Jun; Son, Beom Goo; Kim, Young Jin; Kim, Yun Jae

    2004-01-01

    To investigate relevance of the definition of the reference stress to estimate J and C * for surface crack problems, this paper compares FE J and C * results for surface cracked pipes with those estimated according to the reference stress approach using various definitions of the reference stress. Pipes with part circumferential inner surface crack and finite internal axial crack are considered, subject to internal pressure and global bending. The crack depth and aspect ratio are systematically varied. The reference stress is defined in four different ways using (I) the local limit load, (II) the global limit load, (III) the global limit load determined from the FE limit analysis, and (IV) the optimised reference load. It is found that the reference stress based on the local limit load gives overall excessively conservative estimates of J and C * . Use of the global limit load clearly reduces the conservatism, compared to that of the local limit load, although it can provide sometimes non-conservative estimates of J and C * . The use of the FE global limit load gives overall non-conservative estimates of J and C * . The reference stress based on the optimised reference load gives overall accurate estimates of J and C * , compared to other definitions of the reference stress. Based on the present finding, general guidance on the choice of the reference stress for surface crack problems is given

  1. Standard Test Methods for Electrical Performance of Nonconcentrator Terrestrial Photovoltaic Modules and Arrays Using Reference Cells

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the electrical performance of photovoltaic modules and arrays under natural or simulated sunlight using a calibrated reference cell. 1.1.1 These test methods allow a reference module to be used instead of a reference cell provided the reference module has been calibrated using these test methods against a calibrated reference cell. 1.2 Measurements under a variety of conditions are allowed; results are reported under a select set of reporting conditions (RC) to facilitate comparison of results. 1.3 These test methods apply only to nonconcentrator terrestrial modules and arrays. 1.4 The performance parameters determined by these test methods apply only at the time of the test, and imply no past or future performance level. 1.5 These test methods apply to photovoltaic modules and arrays that do not contain series-connected photovoltaic multijunction devices; such module and arrays should be tested according to Test Methods E 2236. 1.6 The values stated in SI units are to be re...

  2. A self-reference PRF-shift MR thermometry method utilizing the phase gradient

    International Nuclear Information System (INIS)

    Langley, Jason; Potter, William; Phipps, Corey; Zhao Qun; Huang Feng

    2011-01-01

    In magnetic resonance (MR) imaging, the most widely used and accurate method for measuring temperature is based on the shift in proton resonance frequency (PRF). However, inter-scan motion and bulk magnetic field shifts can lead to inaccurate temperature measurements in the PRF-shift MR thermometry method. The self-reference PRF-shift MR thermometry method was introduced to overcome such problems by deriving a reference image from the heated or treated image, and approximates the reference phase map with low-order polynomial functions. In this note, a new approach is presented to calculate the baseline phase map in self-reference PRF-shift MR thermometry. The proposed method utilizes the phase gradient to remove the phase unwrapping step inherent to other self-reference PRF-shift MR thermometry methods. The performance of the proposed method was evaluated using numerical simulations with temperature distributions following a two-dimensional Gaussian function as well as phantom and in vivo experimental data sets. The results from both the numerical simulations and experimental data show that the proposed method is a promising technique for measuring temperature. (note)

  3. Isotachophoresis as a candidate reference method in analytical chemistry. Determination of sodium in serum

    NARCIS (Netherlands)

    Lemmens, A.A.G.; Reijenga, J.C.; Everaerts, F.M.; Janssen, R.T.P.; Hulsman, J.A.R.J.; Meijers, C.A.M.

    1985-01-01

    Isotachophoresis seems a likely candidate for a reference method, as it is more accurate and precise than common routine methods. The response is highly linear and depends on a well defined transport number of the leading ion, stability of the driving current, mobility of the separand, which is well

  4. An independent accurate reference method for the determination of chromium in biological materials

    NARCIS (Netherlands)

    Lagerwaard, A.; Woittiez, J.R.W.; de Goeij, J.J.M.

    1994-01-01

    A method for the determination of Cr in biological materials with high accuracy is reported for use as an independent reference method. It is based on radiochemical neutron activation analysis (RNAA) in combination with an individual yield determination based on the online yield principle. A

  5. EPA eXcats

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA eXcats is an enterprise-level data tracking application that provides management complaint tracking information for the EPA's Office of Civil Rights (OCR)...

  6. EPA Web Taxonomy

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPA's Web Taxonomy is a faceted hierarchical vocabulary used to tag web pages with terms from a controlled vocabulary. Tagging enables search and discovery of EPA's...

  7. Reference methods and materials. A programme of support for regional and global marine pollution assessments

    International Nuclear Information System (INIS)

    1990-01-01

    This document describes a programme of comprehensive support for regional and global marine pollution assessments developed by the United Nations Environment Programme (UNEP) in cooperation with the International Atomic Energy Agency (IAEA) and the Intergovernmental Oceanographic Commission (IOC) and with the collaboration of a number of other United Nations Specialized agencies including the Food and Agriculture Organisation (FAO), the World Meteorological Organisation (WMO), the World Health Organisation (WHO) and the International Maritime Organisation (IMO). Two of the principle components of this programme, Reference Methods and Reference materials are given special attention in this document and a full Reference Method catalogue is included, giving details of over 80 methods currently available or in an advanced stage of preparation and testing. It is important that these methods are seen as a functional component of a much wider strategy necessary for assuring good quality and intercomparable data for regional and global pollution monitoring and the user is encouraged to read this document carefully before employing Reference Methods and Reference Materials in his/her laboratory. 3 figs

  8. References on EPA Quality Assurance Project Plans

    Science.gov (United States)

    Provides requirements for the conduct of quality management practices, including quality assurance (QA) and quality control (QC) activities, for all environmental data collection and environmental technology programs performed by or for this Agency.

  9. 77 FR 55832 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of a New Equivalent Method

    Science.gov (United States)

    2012-09-11

    ... automated monitoring method utilizing a measurement principle based on sample collection by filtration and... 58. Questions concerning the commercial availability or technical aspects of the method should be...

  10. 77 FR 60985 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of Three New Equivalent Methods

    Science.gov (United States)

    2012-10-05

    ... Methods: Designation of Three New Equivalent Methods AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of three new equivalent methods for monitoring ambient air quality. SUMMARY... equivalent methods, one for measuring concentrations of PM 2.5 , one for measuring concentrations of PM 10...

  11. Near-source mobile methane emission estimates using EPA Method33a and a novel probabilistic approach as a basis for leak quantification in urban areas

    Science.gov (United States)

    Albertson, J. D.

    2015-12-01

    Methane emissions from underground pipeline leaks remain an ongoing issue in the development of accurate methane emission inventories for the natural gas supply chain. Application of mobile methods during routine street surveys would help address this issue, but there are large uncertainties in current approaches. In this paper, we describe results from a series of near-source (< 30 m) controlled methane releases where an instrumented van was used to measure methane concentrations during both fixed location sampling and during mobile traverses immediately downwind of the source. The measurements were used to evaluate the application of EPA Method 33A for estimating methane emissions downwind of a source and also to test the application of a new probabilistic approach for estimating emission rates from mobile traverse data.

  12. Normalization Methods and Selection Strategies for Reference Materials in Stable Isotope Analyses - Review

    International Nuclear Information System (INIS)

    Skrzypek, G.; Sadler, R.; Paul, D.; Forizs, I.

    2011-01-01

    A stable isotope analyst has to make a number of important decisions regarding how to best determine the 'true' stable isotope composition of analysed samples in reference to an international scale. It has to be decided which reference materials should be used, the number of reference materials and how many repetitions of each standard is most appropriate for a desired level of precision, and what normalization procedure should be selected. In this paper we summarise what is known about propagation of uncertainties associated with normalization procedures and propagation of uncertainties associated with reference materials used as anchors for the determination of 'true' values for δ''1''3C and δ''1''8O. Normalization methods Several normalization methods transforming the 'raw' value obtained from mass spectrometers to one of the internationally recognized scales has been developed. However, as summarised by Paul et al. different normalization transforms alone may lead to inconsistencies between laboratories. The most common normalization procedures are: single-point anchoring (versus working gas and certified reference standard), modified single-point normalization, linear shift between the measured and the true isotopic composition of two certified reference standards, two-point and multipoint linear normalization methods. The accuracy of these various normalization methods has been compared by using analytical laboratory data by Paul et al., with the single-point and normalization versus tank calibrations resulting in the largest normalization errors, and that also exceed the analytical uncertainty recommended for δ 13 C. The normalization error depends greatly on the relative differences between the stable isotope composition of the reference material and the sample. On the other hand, the normalization methods using two or more certified reference standards produces a smaller normalization error, if the reference materials are bracketing the whole range of

  13. Model Reference Adaptive Control of the Air Flow Rate of Centrifugal Compressor Using State Space Method

    International Nuclear Information System (INIS)

    Han, Jaeyoung; Jung, Mooncheong; Yu, Sangseok; Yi, Sun

    2016-01-01

    In this study, a model reference adaptive controller is developed to regulate the outlet air flow rate of centrifugal compressor for automotive supercharger. The centrifugal compressor is developed using the analytical based method to predict the transient behavior of operating and the designed model is validated with experimental data to confirm the system accuracy. The model reference adaptive control structure consists of a compressor model and a MRAC(model reference adaptive control) mechanism. The feedback control do not robust with variation of system parameter but the applied adaptive control is robust even if the system parameter is changed. As a result, the MRAC was regulated to reference air flow rate. Also MRAC was found to be more robust control compared with the feedback control even if the system parameter is changed.

  14. Model Reference Adaptive Control of the Air Flow Rate of Centrifugal Compressor Using State Space Method

    Energy Technology Data Exchange (ETDEWEB)

    Han, Jaeyoung; Jung, Mooncheong; Yu, Sangseok [Chungnam Nat’l Univ., Daejeon (Korea, Republic of); Yi, Sun [North Carolina A and T State Univ., Raleigh (United States)

    2016-08-15

    In this study, a model reference adaptive controller is developed to regulate the outlet air flow rate of centrifugal compressor for automotive supercharger. The centrifugal compressor is developed using the analytical based method to predict the transient behavior of operating and the designed model is validated with experimental data to confirm the system accuracy. The model reference adaptive control structure consists of a compressor model and a MRAC(model reference adaptive control) mechanism. The feedback control do not robust with variation of system parameter but the applied adaptive control is robust even if the system parameter is changed. As a result, the MRAC was regulated to reference air flow rate. Also MRAC was found to be more robust control compared with the feedback control even if the system parameter is changed.

  15. Assessment of the reference stress method for combined tensile bending and thermal loading

    International Nuclear Information System (INIS)

    Philipp, A.; Munz, D.

    1984-01-01

    The reference stress method has been investigated for combined tensile, bending and thermal loading by considering a uniformly bent beam subjected to superimposed tensile stress and lateral temperature gradients. The creep deformation of the beam can be calculated numerically applying a Norton-type creep law. It turns out that the ratio of curvature rate to strain at the outer fiber depends on the creep exponent. Therefore, the reference stresses for these two quantities must be expected to be different in general. In most load cases, however, it is possible to determine a reference stress which can be used to describe the complete deformation of the beam. The only exception is the case of high tensile loading if the side exposed to higher tensile stress is cooler. Approximate solutions for the reference stress which rely on elastic and limit analyses, can be used only for estimates because they lead to extremely non-conservative predictions. (author)

  16. Ozone Standard Reference Photometer

    Data.gov (United States)

    Federal Laboratory Consortium — The Standard Reference Photometer (SRP) Program began in the early 1980s as collaboration between NIST and the U.S. Environmental Protection Agency (EPA) to design,...

  17. A new method of 3-D cephalometry Part I: the anatomic Cartesian 3-D reference system.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Schutyser, F.A.C.; Barth, E.L.; Groeve, P. De; Mey, A. De

    2006-01-01

    The purpose of this study was to present a new innovative three-dimensional (3-D) cephalometric method. Part I deals with the set-up and validation of a voxel-based semi-automatic 3-D cephalometric reference system. The CT data (DICOM 3.0 files) of 20 control patients with normal skeletal

  18. Determination of trace elements in standard reference materials by the ko-standardization method

    International Nuclear Information System (INIS)

    Smodis, B.; Jacimovic, R.; Stegnar, P.; Jovanovic, S.

    1990-01-01

    The k o -standardization method is suitable for routine multielement determinations by reactor neutron activation analysis (NAA). Investigation of NIST standard reference materials SRM 1571 Orchard Leaves, SRM 1572 Citrus leaves, and SRM 1573 Tomato Leaves showed the systematic error of 12 certified elements determined to be less than 8%. Thirty-four elements were determined in NIST proposed SRM 1515 Apple Leaves

  19. Determination of element concentrations in biological reference materials by solid sampling and other analytical methods

    International Nuclear Information System (INIS)

    Schauenburg, H.; Weigert, P.

    1992-01-01

    Using solid sampling with graphite furnace atomic absorption spectrometry (GFAAS), values for cadmium, copper, lead and zinc in six biological reference materials were obtained from up to four laboratories participating in three collaborative studies. These results are compared with those obtained with other methods used in routine analysis from laboratories of official food control. Under certain conditions solid sampling with GFAAS seems to be suitable for routine analysis as well as conventional methods. (orig.)

  20. Neutron activation analysis of reference materials by the k sub 0 standardization and relative methods

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, M C; Martinho, E [LNETI/ICEN, Sacavem (Portugal)

    1989-04-15

    Instrumental neutron activation analysis with the k{sub o}-standardization method was applied to eight geological, environmental and biological reference materials, including leaves, blood, fish, sediments, soils and limestone. To a first approximation, the results were normally distributed around the certified values with a standard deviation of 10%. Results obtained by using the relative method based on well characterized multi-element standards for IAEA CRM Soil-7 are reported.

  1. A preliminary verification of the floating reference measurement method for non-invasive blood glucose sensing

    Science.gov (United States)

    Min, Xiaolin; Liu, Rong; Fu, Bo; Xu, Kexin

    2017-06-01

    In the non-invasive sensing of blood glucose by near-infrared diffuse reflectance spectroscopy, the spectrum is highly susceptible to the unstable and complicated background variations from the human body and the environment. In in vitro analyses, background variations are usually corrected by the spectrum of a standard reference sample that has similar optical properties to the analyte of interest. However, it is hard to find a standard sample for the in vivo measurement. Therefore, the floating reference measurement method is proposed to enable relative measurements in vivo, where the spectra under some special source-detector distance, defined as the floating reference position, are insensitive to the changes in glucose concentration due to the absorption effect and scattering effect. Because the diffuse reflectance signals at the floating reference positions only reflect the information on background variations during the measurement, they can be used as the internal reference. In this paper, the theoretical basis of the floating reference positions in a semi-infinite turbid medium was discussed based on the steady-state diffusion equation and its analytical solutions in a semi-infinite turbid medium (under the extrapolated boundary conditions). Then, Monte-Carlo (MC) simulations and in vitro experiments based on a custom-built continuous-moving spatially resolving double-fiber NIR measurement system, configured with two types of light source, a super luminescent diode (SLD) and a super-continuum laser, were carried out to verify the existence of the floating reference position in 5%, 10% and 20% Intralipid solutions. The results showed that the simulation values of the floating reference positions are close to the theoretical results, with a maximum deviation of approximately 0.3 mm in 1100-1320 nm. Great differences can be observed in 1340-1400 nm because the optical properties of Intralipid in this region don not satisfy the conditions of the steady

  2. Standard Test Method for Calibration of Primary Non-Concentrator Terrestrial Photovoltaic Reference Cells Using a Tabular Spectrum

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method is intended to be used for calibration and characterization of primary terrestrial photovoltaic reference cells to a desired reference spectral irradiance distribution, such as Tables G173. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of photovoltaic devices. 1.2 Primary photovoltaic reference cells are calibrated in natural sunlight using the relative spectral response of the cell, the relative spectral distribution of the sunlight, and a tabulated reference spectral irradiance distribution. 1.3 This test method requires the use of a pyrheliometer that is calibrated according to Test Method E816, which requires the use of a pyrheliometer that is traceable to the World Radiometric Reference (WRR). Therefore, reference cells calibrated according to this test method are traceable to the WRR. 1.4 This test method is a technique that may be used ...

  3. EPA's Benchmark Dose Modeling Software

    Science.gov (United States)

    The EPA developed the Benchmark Dose Software (BMDS) as a tool to help Agency risk assessors facilitate applying benchmark dose (BMD) method’s to EPA’s human health risk assessment (HHRA) documents. The application of BMD methods overcomes many well know limitations ...

  4. Recent advances in ratio primary reference measurement procedures (definitive methods) and their use in certification of reference materials and controlling assigned values in proficiency testing

    International Nuclear Information System (INIS)

    Dybczynski, R.S.; Polkowska-Motrenko, H.; Chajduk, E.; Danko, B.; Pyszynska, M.

    2014-01-01

    Three very accurate (definitive) methods by RNAA for the determination of Se, As and Fe respectively, which were recently elaborated in our laboratory, are reviewed and their use in certification of reference materials and in checking the assigned values in proficiency tests is demonstrated on several examples. According to VIM 3 nomenclature these methods may be called: ratio primary reference measurement procedures (RPRMPs). RPRMPs with their expanded uncertainties of 2.7-3.6 % are comparable to ID-MS methods and are the only methods of such high metrological quality which can be used for the determination of trace amounts of monoisotopic elements. (author)

  5. A novel no-reference objective stereoscopic video quality assessment method based on visual saliency analysis

    Science.gov (United States)

    Yang, Xinyan; Zhao, Wei; Ye, Long; Zhang, Qin

    2017-07-01

    This paper proposes a no-reference objective stereoscopic video quality assessment method with the motivation that making the effect of objective experiments close to that of subjective way. We believe that the image regions with different visual salient degree should not have the same weights when designing an assessment metric. Therefore, we firstly use GBVS algorithm to each frame pairs and separate both the left and right viewing images into the regions with strong, general and week saliency. Besides, local feature information like blockiness, zero-crossing and depth are extracted and combined with a mathematical model to calculate a quality assessment score. Regions with different salient degree are assigned with different weights in the mathematical model. Experiment results demonstrate the superiority of our method compared with the existed state-of-the-art no-reference objective Stereoscopic video quality assessment methods.

  6. A frequency domain global parameter estimation method for multiple reference frequency response measurements

    Science.gov (United States)

    Shih, C. Y.; Tsuei, Y. G.; Allemang, R. J.; Brown, D. L.

    1988-10-01

    A method of using the matrix Auto-Regressive Moving Average (ARMA) model in the Laplace domain for multiple-reference global parameter identification is presented. This method is particularly applicable to the area of modal analysis where high modal density exists. The method is also applicable when multiple reference frequency response functions are used to characterise linear systems. In order to facilitate the mathematical solution, the Forsythe orthogonal polynomial is used to reduce the ill-conditioning of the formulated equations and to decouple the normal matrix into two reduced matrix blocks. A Complex Mode Indicator Function (CMIF) is introduced, which can be used to determine the proper order of the rational polynomials.

  7. A Reference Point Construction Method Using Mobile Terminals and the Indoor Localization Evaluation in the Centroid Method

    Directory of Open Access Journals (Sweden)

    Takahiro Yamaguchi

    2015-05-01

    Full Text Available As smartphones become widespread, a variety of smartphone applications are being developed. This paper proposes a method for indoor localization (i.e., positioning that uses only smartphones, which are general-purpose mobile terminals, as reference point devices. This method has the following features: (a the localization system is built with smartphones whose movements are confined to respective limited areas. No fixed reference point devices are used; (b the method does not depend on the wireless performance of smartphones and does not require information about the propagation characteristics of the radio waves sent from reference point devices, and (c the method determines the location at the application layer, at which location information can be easily incorporated into high-level services. We have evaluated the level of localization accuracy of the proposed method by building a software emulator that modeled an underground shopping mall. We have confirmed that the determined location is within a small area in which the user can find target objects visually.

  8. The establishment of tocopherol reference intervals for Hungarian adult population using a validated HPLC method.

    Science.gov (United States)

    Veres, Gábor; Szpisjak, László; Bajtai, Attila; Siska, Andrea; Klivényi, Péter; Ilisz, István; Földesi, Imre; Vécsei, László; Zádori, Dénes

    2017-09-01

    Evidence suggests that decreased α-tocopherol (the most biologically active substance in the vitamin E group) level can cause neurological symptoms, most likely ataxia. The aim of the current study was to first provide reference intervals for serum tocopherols in the adult Hungarian population with appropriate sample size, recruiting healthy control subjects and neurological patients suffering from conditions without symptoms of ataxia, myopathy or cognitive deficiency. A validated HPLC method applying a diode array detector and rac-tocol as internal standard was utilized for that purpose. Furthermore, serum cholesterol levels were determined as well for data normalization. The calculated 2.5-97.5% reference intervals for α-, β/γ- and δ-tocopherols were 24.62-54.67, 0.81-3.69 and 0.29-1.07 μm, respectively, whereas the tocopherol/cholesterol ratios were 5.11-11.27, 0.14-0.72 and 0.06-0.22 μmol/mmol, respectively. The establishment of these reference intervals may improve the diagnostic accuracy of tocopherol measurements in certain neurological conditions with decreased tocopherol levels. Moreover, the current study draws special attention to the possible pitfalls in the complex process of the determination of reference intervals as well, including the selection of study population, the application of internal standard and method validation and the calculation of tocopherol/cholesterol ratios. Copyright © 2017 John Wiley & Sons, Ltd.

  9. A quasiparticle-based multi-reference coupled-cluster method.

    Science.gov (United States)

    Rolik, Zoltán; Kállay, Mihály

    2014-10-07

    The purpose of this paper is to introduce a quasiparticle-based multi-reference coupled-cluster (MRCC) approach. The quasiparticles are introduced via a unitary transformation which allows us to represent a complete active space reference function and other elements of an orthonormal multi-reference (MR) basis in a determinant-like form. The quasiparticle creation and annihilation operators satisfy the fermion anti-commutation relations. On the basis of these quasiparticles, a generalization of the normal-ordered operator products for the MR case can be introduced as an alternative to the approach of Mukherjee and Kutzelnigg [Recent Prog. Many-Body Theor. 4, 127 (1995); Mukherjee and Kutzelnigg, J. Chem. Phys. 107, 432 (1997)]. Based on the new normal ordering any quasiparticle-based theory can be formulated using the well-known diagram techniques. Beyond the general quasiparticle framework we also present a possible realization of the unitary transformation. The suggested transformation has an exponential form where the parameters, holding exclusively active indices, are defined in a form similar to the wave operator of the unitary coupled-cluster approach. The definition of our quasiparticle-based MRCC approach strictly follows the form of the single-reference coupled-cluster method and retains several of its beneficial properties. Test results for small systems are presented using a pilot implementation of the new approach and compared to those obtained by other MR methods.

  10. GMOMETHODS: the European Union database of reference methods for GMO analysis.

    Science.gov (United States)

    Bonfini, Laura; Van den Bulcke, Marc H; Mazzara, Marco; Ben, Enrico; Patak, Alexandre

    2012-01-01

    In order to provide reliable and harmonized information on methods for GMO (genetically modified organism) analysis we have published a database called "GMOMETHODS" that supplies information on PCR assays validated according to the principles and requirements of ISO 5725 and/or the International Union of Pure and Applied Chemistry protocol. In addition, the database contains methods that have been verified by the European Union Reference Laboratory for Genetically Modified Food and Feed in the context of compliance with an European Union legislative act. The web application provides search capabilities to retrieve primers and probes sequence information on the available methods. It further supplies core data required by analytical labs to carry out GM tests and comprises information on the applied reference material and plasmid standards. The GMOMETHODS database currently contains 118 different PCR methods allowing identification of 51 single GM events and 18 taxon-specific genes in a sample. It also provides screening assays for detection of eight different genetic elements commonly used for the development of GMOs. The application is referred to by the Biosafety Clearing House, a global mechanism set up by the Cartagena Protocol on Biosafety to facilitate the exchange of information on Living Modified Organisms. The publication of the GMOMETHODS database can be considered an important step toward worldwide standardization and harmonization in GMO analysis.

  11. "Slicer" for EPA

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    During the design of the Electron-Positron-Accumulator (EPA), there was an apprehension about the stability-limit of positron bunch-intensity in the SPS. In case that EPA would be able to produce bunches with intensities exceeding what the SPS could digest, an electrostatic septum was to slice up the EPA beam over 2 or 4 turns, thus lowering the bunch intensity while maintaining fast filling of LEP. The "slicer" septum was built and installed, but thanks to the good appetite of the SPS its use never became necessary. The slicer was removed from EPA to lower the machine impedance.

  12. EPA Envirofacts API

    Data.gov (United States)

    U.S. Environmental Protection Agency — Envirofacts integrates information from a variety of EPA's environmental databases. Each of these databases contains information about facilities that are required...

  13. Matrix pencil method-based reference current generation for shunt active power filters

    DEFF Research Database (Denmark)

    Terriche, Yacine; Golestan, Saeed; Guerrero, Josep M.

    2018-01-01

    response and works well under distorted and unbalanced voltage. Moreover, the proposed method can estimate the voltage phase accurately; this property enables the algorithm to compensate for both power factor and current unbalance. The effectiveness of the proposed method is verified using simulation...... are using the discrete Fourier transform (DFT) in the frequency domain or the instantaneous p–q theory and the synchronous reference frame in the time domain. The DFT, however, suffers from the picket-fence effect and spectral leakage. On the other hand, the DFT takes at least one cycle of the nominal...... frequency. The time-domain methods show a weakness under voltage distortion, which requires prior filtering techniques. The aim of this study is to present a fast yet effective method for generating the RCC for SAPFs. The proposed method, which is based on the matrix pencil method, has a fast dynamic...

  14. EPA Method 3135.2I: Cyanide, Total and Amenable in Aqueous and Solid Samples Automated Colorimetric With Manual Digestion

    Science.gov (United States)

    This method describes procedures for preparation and analysis of solid, water and wipe samples for detection and measurement of cyanide amendable to chlorination using acid digestion and spectrophotometry.

  15. Verification of chemistry reference ranges using a simple method in sub-Saharan Africa

    Directory of Open Access Journals (Sweden)

    Irith De Baetselier

    2016-10-01

    Full Text Available Background: Chemistry safety assessments are interpreted by using chemistry reference ranges (CRRs. Verification of CRRs is time consuming and often requires a statistical background. Objectives: We report on an easy and cost-saving method to verify CRRs. Methods: Using a former method introduced by Sigma Diagnostics, three study sites in sub- Saharan Africa, Bondo, Kenya, and Pretoria and Bloemfontein, South Africa, verified the CRRs for hepatic and renal biochemistry assays performed during a clinical trial of HIV antiretroviral pre-exposure prophylaxis. The aspartate aminotransferase/alanine aminotransferase, creatinine and phosphorus results from 10 clinically-healthy participants at the screening visit were used. In the event the CRRs did not pass the verification, new CRRs had to be calculated based on 40 clinically-healthy participants. Results: Within a few weeks, the study sites accomplished verification of the CRRs without additional costs. The aspartate aminotransferase reference ranges for the Bondo, Kenya site and the alanine aminotransferase reference ranges for the Pretoria, South Africa site required adjustment. The phosphorus CRR passed verification and the creatinine CRR required adjustment at every site. The newly-established CRR intervals were narrower than the CRRs used previously at these study sites due to decreases in the upper limits of the reference ranges. As a result, more toxicities were detected. Conclusion: To ensure the safety of clinical trial participants, verification of CRRs should be standard practice in clinical trials conducted in settings where the CRR has not been validated for the local population. This verification method is simple, inexpensive, and can be performed by any medical laboratory.

  16. Precision and Accuracy of k0-NAA Method for Analysis of Multi Elements in Reference Samples

    International Nuclear Information System (INIS)

    Sri-Wardani

    2004-01-01

    Accuracy and precision of k 0 -NAA method could determine in the analysis of multi elements contained in reference samples. The analyzed results of multi elements in SRM 1633b sample were obtained with optimum results in bias of 20% but it is in a good accuracy and precision. The analyzed results of As, Cd and Zn in CCQM-P29 rice flour sample were obtained with very good result in bias of 0.5 - 5.6%. (author)

  17. The complementary use of radioanalytical methods and trace analysis methods for the characterisation of environmental IAEA reference materials

    International Nuclear Information System (INIS)

    De Regge, P.; Burns, K.; Campbell, M.; Makarewicz, M.; Markowicz, A.; Mattiuzzi, M.; Tajani, A.; Toervenyi, A.; Zeiller, E.

    2001-01-01

    The IAEA laboratories have access to both nuclear analytical methods and conventional instrumental methods for trace analysis for the characterisation of its environmental and biological reference materials. A technical concept integrating the homogeneity data, the recommended test portion mass and the uncertainty on the trace element concentrations is explored using a combination of INAA, XRF, ICP-MS, ICP-AES, and AAS. The above approach is illustrated by selected examples of reference materials currently under evaluation for their trace element content. They include some or all of the following elements Al, As, Br, Ca, Cd, Co, Cr, Cs, Cu, Fe, Hg, K, Mg, Mn, Mo, Na, Ni, Pb, Rb, Se, Sr, Th, U, Zn in environmental biomonitor organisms (lichen, algae) and air dust filters. (author)

  18. Identification of reliable gridded reference data for statistical downscaling methods in Alberta

    Science.gov (United States)

    Eum, H. I.; Gupta, A.

    2017-12-01

    Climate models provide essential information to assess impacts of climate change at regional and global scales. However, statistical downscaling methods have been applied to prepare climate model data for various applications such as hydrologic and ecologic modelling at a watershed scale. As the reliability and (spatial and temporal) resolution of statistically downscaled climate data mainly depend on a reference data, identifying the most reliable reference data is crucial for statistical downscaling. A growing number of gridded climate products are available for key climate variables which are main input data to regional modelling systems. However, inconsistencies in these climate products, for example, different combinations of climate variables, varying data domains and data lengths and data accuracy varying with physiographic characteristics of the landscape, have caused significant challenges in selecting the most suitable reference climate data for various environmental studies and modelling. Employing various observation-based daily gridded climate products available in public domain, i.e. thin plate spline regression products (ANUSPLIN and TPS), inverse distance method (Alberta Townships), and numerical climate model (North American Regional Reanalysis) and an optimum interpolation technique (Canadian Precipitation Analysis), this study evaluates the accuracy of the climate products at each grid point by comparing with the Adjusted and Homogenized Canadian Climate Data (AHCCD) observations for precipitation, minimum and maximum temperature over the province of Alberta. Based on the performance of climate products at AHCCD stations, we ranked the reliability of these publically available climate products corresponding to the elevations of stations discretized into several classes. According to the rank of climate products for each elevation class, we identified the most reliable climate products based on the elevation of target points. A web-based system

  19. EPA Method 3031 (SW-846): Acid Digestion of Oils for Metals Analysis by Atomic Absorption or ICP Spectrometry

    Science.gov (United States)

    Procedures are described for analysis of water samples and may be adapted for assessment of solid, particulate and liquid samples. The method uses real-time PCR assay for detecting Toxoplasma gondii DNA using gene-specific primers and probe.

  20. Improvements in the equipment for determination of Kr-85 with the reference method

    International Nuclear Information System (INIS)

    Heras Iniquez, M.C.; Perez Garcia, M.M.

    1983-01-01

    A new equipment for Kr-85 separation and their cryogenic chromatographic concentration is described, which presents some advantages respect the equipment used as reference. The new apparatus, made with metallic elements, is based on the method of concentration and separation previously described but presents easier control, faster chromatographic separations and without loosed of efficiency and reproducibility that the previous one. The concentration and separation procedure for Kr-85 and a comparative study between both apparatus is described. Also the efficiency of the method is obtained experimentally. (Author)

  1. Method of collective variables with reference system for the grand canonical ensemble

    International Nuclear Information System (INIS)

    Yukhnovskii, I.R.

    1989-01-01

    A method of collective variables with special reference system for the grand canonical ensemble is presented. An explicit form is obtained for the basis sixth-degree measure density needed to describe the liquid-gas phase transition. Here the author presents the fundamentals of the method, which are as follows: (1) the functional form for the partition function in the grand canonical ensemble; (2) derivation of thermodynamic relations for the coefficients of the Jacobian; (3) transition to the problem on an adequate lattice; and (4) obtaining of the explicit form for the functional of the partition function

  2. Verification of chemistry reference ranges using a simple method in sub-Saharan Africa.

    Science.gov (United States)

    De Baetselier, Irith; Taylor, Douglas; Mandala, Justin; Nanda, Kavita; Van Campenhout, Christel; Agingu, Walter; Madurai, Lorna; Barsch, Eva-Maria; Deese, Jennifer; Van Damme, Lut; Crucitti, Tania

    2016-01-01

    Chemistry safety assessments are interpreted by using chemistry reference ranges (CRRs). Verification of CRRs is time consuming and often requires a statistical background. We report on an easy and cost-saving method to verify CRRs. Using a former method introduced by Sigma Diagnostics, three study sites in sub-Saharan Africa, Bondo, Kenya, and Pretoria and Bloemfontein, South Africa, verified the CRRs for hepatic and renal biochemistry assays performed during a clinical trial of HIV antiretroviral pre-exposure prophylaxis. The aspartate aminotransferase/alanine aminotransferase, creatinine and phosphorus results from 10 clinically-healthy participants at the screening visit were used. In the event the CRRs did not pass the verification, new CRRs had to be calculated based on 40 clinically-healthy participants. Within a few weeks, the study sites accomplished verification of the CRRs without additional costs. The aspartate aminotransferase reference ranges for the Bondo, Kenya site and the alanine aminotransferase reference ranges for the Pretoria, South Africa site required adjustment. The phosphorus CRR passed verification and the creatinine CRR required adjustment at every site. The newly-established CRR intervals were narrower than the CRRs used previously at these study sites due to decreases in the upper limits of the reference ranges. As a result, more toxicities were detected. To ensure the safety of clinical trial participants, verification of CRRs should be standard practice in clinical trials conducted in settings where the CRR has not been validated for the local population. This verification method is simple, inexpensive, and can be performed by any medical laboratory.

  3. Resampling Approach for Determination of the Method for Reference Interval Calculation in Clinical Laboratory Practice▿

    Science.gov (United States)

    Pavlov, Igor Y.; Wilson, Andrew R.; Delgado, Julio C.

    2010-01-01

    Reference intervals (RI) play a key role in clinical interpretation of laboratory test results. Numerous articles are devoted to analyzing and discussing various methods of RI determination. The two most widely used approaches are the parametric method, which assumes data normality, and a nonparametric, rank-based procedure. The decision about which method to use is usually made arbitrarily. The goal of this study was to demonstrate that using a resampling approach for the comparison of RI determination techniques could help researchers select the right procedure. Three methods of RI calculation—parametric, transformed parametric, and quantile-based bootstrapping—were applied to multiple random samples drawn from 81 values of complement factor B observations and from a computer-simulated normally distributed population. It was shown that differences in RI between legitimate methods could be up to 20% and even more. The transformed parametric method was found to be the best method for the calculation of RI of non-normally distributed factor B estimations, producing an unbiased RI and the lowest confidence limits and interquartile ranges. For a simulated Gaussian population, parametric calculations, as expected, were the best; quantile-based bootstrapping produced biased results at low sample sizes, and the transformed parametric method generated heavily biased RI. The resampling approach could help compare different RI calculation methods. An algorithm showing a resampling procedure for choosing the appropriate method for RI calculations is included. PMID:20554803

  4. Cheminformatics Analysis of EPA ToxCast Chemical Libraries ...

    Science.gov (United States)

    An important goal of toxicology research is the development of robust methods that use in vitro and chemical structure information to predict in vivo toxicity endpoints. The US EPA ToxCast program is addressing this goal using ~600 in vitro assays to create bioactivity profiles on a set of 320 compounds, mostly pesticide actives, that have well characterized in vivo toxicity. These 320 compounds (EPA-320 set evaluated in Phase I of ToxCast) are a subset of a much larger set of ~10,000 candidates that are of interest to the EPA (called here EPA-10K). Predictive models of in vivo toxicity are being constructed from the in vitro assay data on the EPA-320 chemical set. These models require validation on additional chemicals prior to wide acceptance, and this will be carried out by evaluating compounds from EPA-10K in Phase II of ToxCast. We have used cheminformatics approaches including clustering, data visualization, and QSAR to develop models for EPA-320 that could help prioritizing EPA-10K validation chemicals. Both chemical descriptors, as well as calculated physicochemical properties have been used. Compounds from EPA-10K are prioritized based on their similarity to EPA-320 using different similarity metrics, with similarity thresholds defining the domain of applicability for the predictive models built for EPA-320 set. In addition, prioritized lists of compounds of increasing dissimilarity from the EPA-320 have been produced, to test the ability of the EPA-320

  5. EPA`s program for risk assessment guidelines: Quantification issues

    Energy Technology Data Exchange (ETDEWEB)

    Dourson, M.L. [Environmental Protection Agency, Washington, DC (United States)

    1990-12-31

    The quantitative procedures associated with noncancer risk assessment include reference dose (RfD), benchmark dose, and severity modeling. The RfD, which is part of the EPA risk assessment guidelines, is an estimation of a level that is likely to be without any health risk to sensitive individuals. The RfD requires two major judgments: the first is choice of a critical effect(s) and its No Observed Adverse Effect Level (NOAEL); the second judgment is choice of an uncertainty factor. This paper discusses major assumptions and limitations of the RfD model.

  6. ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-05-01

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either of those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.

  7. Reference voltage calculation method based on zero-sequence component optimisation for a regional compensation DVR

    Science.gov (United States)

    Jian, Le; Cao, Wang; Jintao, Yang; Yinge, Wang

    2018-04-01

    This paper describes the design of a dynamic voltage restorer (DVR) that can simultaneously protect several sensitive loads from voltage sags in a region of an MV distribution network. A novel reference voltage calculation method based on zero-sequence voltage optimisation is proposed for this DVR to optimise cost-effectiveness in compensation of voltage sags with different characteristics in an ungrounded neutral system. Based on a detailed analysis of the characteristics of voltage sags caused by different types of faults and the effect of the wiring mode of the transformer on these characteristics, the optimisation target of the reference voltage calculation is presented with several constraints. The reference voltages under all types of voltage sags are calculated by optimising the zero-sequence component, which can reduce the degree of swell in the phase-to-ground voltage after compensation to the maximum extent and can improve the symmetry degree of the output voltages of the DVR, thereby effectively increasing the compensation ability. The validity and effectiveness of the proposed method are verified by simulation and experimental results.

  8. A simple and effective method to achieve the successful start-up of a current reference

    International Nuclear Information System (INIS)

    Han Lei; Zhang Xiaoxing; Dai Yujie; Lü Yingjie; Wang Yujun

    2012-01-01

    Start-up design is a critical issue in current reference as it is very closely related to production yield. However, its function is difficult to predict using normal transaction simulations before the device is put into diffusion. In this paper, we discuss a simple and effective simulation approach which ensures a successful start-up process in a self-biased temperature independent current reference. The circuit is implemented in a class-D power amplifier with a 0.35 μm BiCMOS process and the experimental result validates that, by using this method, the start-up success rate can be greatly improved to 100%. (semiconductor integrated circuits)

  9. EPA Linked Open Data (Collection)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is a collection item referencing the following EPA Linked Data resources: - EPA Facility Registry Service (FRS) - EPA Substance Registry Service (SRS) -...

  10. EPA Library Network Communication Strategies

    Science.gov (United States)

    To establish Agency-wide procedures for the EPA National Library Network libraries to communicate, using a range of established mechanisms, with other EPA libraries, EPA staff, organizations and the public.

  11. Comparison of analytical methods for the determination of histamine in reference canned fish samples

    Science.gov (United States)

    Jakšić, S.; Baloš, M. Ž.; Mihaljev, Ž.; Prodanov Radulović, J.; Nešić, K.

    2017-09-01

    Two screening methods for histamine in canned fish, an enzymatic test and a competitive direct enzyme-linked immunosorbent assay (CD-ELISA), were compared with the reversed-phase liquid chromatography (RP-HPLC) standard method. For enzymatic and CD-ELISA methods, determination was conducted according to producers’ manuals. For RP-HPLC, histamine was derivatized with dansyl-chloride, followed by RP-HPLC and diode array detection. Results of analysis of canned fish, supplied as reference samples for proficiency testing, showed good agreement when histamine was present at higher concentrations (above 100 mg kg-1). At a lower level (16.95 mg kg-1), the enzymatic test produced some higher results. Generally, analysis of four reference samples according to CD-ELISA and RP-HPLC showed good agreement for histamine determination (r=0.977 in concentration range 16.95-216 mg kg-1) The results show that the applied enzymatic test and CD-ELISA appeared to be suitable screening methods for the determination of histamine in canned fish.

  12. Evaluation of different methods to estimate daily reference evapotranspiration in ungauged basins in Southern Brazil

    Science.gov (United States)

    Ribeiro Fontoura, Jessica; Allasia, Daniel; Herbstrith Froemming, Gabriel; Freitas Ferreira, Pedro; Tassi, Rutineia

    2016-04-01

    Evapotranspiration is a key process of hydrological cycle and a sole term that links land surface water balance and land surface energy balance. Due to the higher information requirements of the Penman-Monteith method and the existing data uncertainty, simplified empirical methods for calculating potential and actual evapotranspiration are widely used in hydrological models. This is especially important in Brazil, where the monitoring of meteorological data is precarious. In this study were compared different methods for estimating evapotranspiration for Rio Grande do Sul, the Southernmost State of Brazil, aiming to suggest alternatives to the recommended method (Penman-Monteith-FAO 56) for estimate daily reference evapotranspiration (ETo) when meteorological data is missing or not available. The input dataset included daily and hourly-observed data from conventional and automatic weather stations respectively maintained by the National Weather Institute of Brazil (INMET) from the period of 1 January 2007 to 31 January 2010. Dataset included maximum temperature (Tmax, °C), minimum temperature (Tmin, °C), mean relative humidity (%), wind speed at 2 m height (u2, m s-1), daily solar radiation (Rs, MJ m- 2) and atmospheric pressure (kPa) that were grouped at daily time-step. Was tested the Food and Agriculture Organization of the United Nations (FAO) Penman-Monteith method (PM) at its full form, against PM assuming missing several variables not normally available in Brazil in order to calculate daily reference ETo. Missing variables were estimated as suggested in FAO56 publication or from climatological means. Furthermore, PM was also compared against the following simplified empirical methods: Hargreaves-Samani, Priestley-Taylor, Mccloud, McGuiness-Bordne, Romanenko, Radiation-Temperature, Tanner-Pelton. The statistical analysis indicates that even if just Tmin and Tmax are available, it is better to use PM estimating missing variables from syntetic data than

  13. Performance of different methods for reference evapotranspiration estimation in Jaíba, Brazil

    Directory of Open Access Journals (Sweden)

    Gustavo H. da Silva

    Full Text Available ABSTRACT FAO Penman-Monteith (FO-PM is considered the standard method for the estimation of reference evapotranspiration (ET0 but requires various meteorological data, which are often not available. The objective of this work was to evaluate the performance of the FAO-PM method with limited meteorological data and other methods as alternatives to estimate ET0 in Jaíba-MG. The study used daily meteorological data from 2007 to 2016 of the National Institute of Meteorology’s station. Daily ET0 values were randomized, and 70% of these were used to determine the calibration parameters of the ET0 for the equations of each method under study. The remaining data were used to test the calibration against the standard method. Performance evaluation was based on Willmott’s index of agreement, confidence coefficient and root-mean-square error. When one meteorological variable was missing, either solar radiation, relative air humidity or wind speed, or in the simultaneous absence of wind speed and relative air humidity, the FAO-PM method showed the best performances and, therefore, was recommended for Jaíba. The FAO-PM method with two missing variables, one of them being solar radiation, showed intermediate performance. Methods that used only air temperature data are not recommended for the region.

  14. Performance of NAA methods in an International Interlaboratory Reference Material Characterization Campaign

    International Nuclear Information System (INIS)

    Ihnat, M.

    2000-01-01

    An extensive database of analytical results from a recent biological matrix Reference Material Characterization Campaign permitted an intercomparison of the performances of various methods among each other and with 'true' best estimate concentration values established for these materials. Six different variants of neutron activation analysis (NAA) methods were employed including: instrumental neutron activation analysis, instrumental neutron activation analysis with acid digestion, neutron activation analysis with radiochemical separation, neutron capture prompt gamma activation analysis, epithermal instrumental neutron activation analysis, and neutron activation analysis with preconcentration. The precision and accuracy performance of NAA-based analytical methods are compared with three other major techniques, atomic absorption spectrometry (AAS), atomic emission spectrometry (AES) and mass spectrometry (MS) for 28 elements in 10 natural matrix materials. (author)

  15. Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of the electrical performance of a photovoltaic cell under simulated sunlight by means of a calibrated reference cell procedure. 1.2 Electrical performance measurements are reported with respect to a select set of standard reporting conditions (SRC) (see Table 1) or to user-specified conditions. 1.2.1 The SRC or user-specified conditions include the cell temperature, the total irradiance, and the reference spectral irradiance distribution. 1.3 This test method is applicable only to photovoltaic cells with a linear response over the range of interest. 1.4 The cell parameters determined by this test method apply only at the time of test, and imply no past or future performance level. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this s...

  16. Repositioning reference new methods and new services for a new age

    CERN Document Server

    Rozaklis, Lillian

    2014-01-01

    Repositioning Reference reimagines reference services in libraries and information organizations and the role of reference librarians, taking into account rapid developments in technology and information-specific services in non-library sectors.

  17. Deviation of landmarks in accordance with methods of establishing reference planes in three-dimensional facial CT evaluation.

    Science.gov (United States)

    Yoon, Kaeng Won; Yoon, Suk-Ja; Kang, Byung-Cheol; Kim, Young-Hee; Kook, Min Suk; Lee, Jae-Seo; Palomo, Juan Martin

    2014-09-01

    This study aimed to investigate the deviation of landmarks from horizontal or midsagittal reference planes according to the methods of establishing reference planes. Computed tomography (CT) scans of 18 patients who received orthodontic and orthognathic surgical treatment were reviewed. Each CT scan was reconstructed by three methods for establishing three orthogonal reference planes (namely, the horizontal, midsagittal, and coronal reference planes). The horizontal (bilateral porions and bilateral orbitales) and midsagittal (crista galli, nasion, prechiasmatic point, opisthion, and anterior nasal spine) landmarks were identified on each CT scan. Vertical deviation of the horizontal landmarks and horizontal deviation of the midsagittal landmarks were measured. The porion and orbitale, which were not involved in establishing the horizontal reference plane, were found to deviate vertically from the horizontal reference plane in the three methods. The midsagittal landmarks, which were not used for the midsagittal reference plane, deviated horizontally from the midsagittal reference plane in the three methods. In a three-dimensional facial analysis, the vertical and horizontal deviations of the landmarks from the horizontal and midsagittal reference planes could vary depending on the methods of establishing reference planes.

  18. Deviation of landmarks in accordance with methods of establishing reference planes in three-dimensional facial CT evaluation

    International Nuclear Information System (INIS)

    Yoon, Kaeng Won; Yoon, Suk Ja; Kang, Byung Cheol; Kook, Min Suk; Lee, Jae Seo; Kim, Young Hee; Palomo, Juan Martin

    2014-01-01

    This study aimed to investigate the deviation of landmarks from horizontal or midsagittal reference planes according to the methods of establishing reference planes. Computed tomography (CT) scans of 18 patients who received orthodontic and orthognathic surgical treatment were reviewed. Each CT scan was reconstructed by three methods for establishing three orthogonal reference planes (namely, the horizontal, midsagittal, and coronal reference planes). The horizontal (bilateral porions and bilateral orbitales) and midsagittal (crista galli, nasion, prechiasmatic point, opisthion, and anterior nasal spine) landmarks were identified on each CT scan. Vertical deviation of the horizontal landmarks and horizontal deviation of the midsagittal landmarks were measured. The porion and orbitale, which were not involved in establishing the horizontal reference plane, were found to deviate vertically from the horizontal reference plane in the three methods. The midsagittal landmarks, which were not used for the midsagittal reference plane, deviated horizontally from the midsagittal reference plane in the three methods. In a three-dimensional facial analysis, the vertical and horizontal deviations of the landmarks from the horizontal and midsagittal reference planes could vary depending on the methods of establishing reference planes.

  19. Deviation of landmarks in accordance with methods of establishing reference planes in three-dimensional facial CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Kaeng Won; Yoon, Suk Ja; Kang, Byung Cheol; Kook, Min Suk; Lee, Jae Seo [School of Dentistry, Dental Science Research Institute, Chonnam National University, Gwangju (Korea, Republic of); Kim, Young Hee [Dept. of Oral and Maxillofacial Radiology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Palomo, Juan Martin [Dept. of Orthodontics, School of Dental Medicine, Case Western Reserve University, Cleveland (Korea, Republic of)

    2014-09-15

    This study aimed to investigate the deviation of landmarks from horizontal or midsagittal reference planes according to the methods of establishing reference planes. Computed tomography (CT) scans of 18 patients who received orthodontic and orthognathic surgical treatment were reviewed. Each CT scan was reconstructed by three methods for establishing three orthogonal reference planes (namely, the horizontal, midsagittal, and coronal reference planes). The horizontal (bilateral porions and bilateral orbitales) and midsagittal (crista galli, nasion, prechiasmatic point, opisthion, and anterior nasal spine) landmarks were identified on each CT scan. Vertical deviation of the horizontal landmarks and horizontal deviation of the midsagittal landmarks were measured. The porion and orbitale, which were not involved in establishing the horizontal reference plane, were found to deviate vertically from the horizontal reference plane in the three methods. The midsagittal landmarks, which were not used for the midsagittal reference plane, deviated horizontally from the midsagittal reference plane in the three methods. In a three-dimensional facial analysis, the vertical and horizontal deviations of the landmarks from the horizontal and midsagittal reference planes could vary depending on the methods of establishing reference planes.

  20. Tentative reference method for measurement of tritium in environmental waters. Environmental monitoring series

    International Nuclear Information System (INIS)

    1975-12-01

    A tentative reference method for the measurement of tritium in potable and nonpotable environmental water is described. Water samples are treated with sodium hydroxide and potassium permanganate and then a water fraction is separated from interferences by distillation. Two distillation procedures are described, a simple aqueous distillation for samples from potable water sources, and an aqueous-azeotropic-benzene distillation for nonpotable water sources. Alliquots of a designated distillate fraction are measured for tritium activity by liquid scintillation detection. Distillation recovery and counting efficiency factors are determined with tritium standards. Results are reported in picocuries per milliliter

  1. Assessment of air quality microsensors versus reference methods: The EuNetAir joint exercise

    Science.gov (United States)

    Borrego, C.; Costa, A. M.; Ginja, J.; Amorim, M.; Coutinho, M.; Karatzas, K.; Sioumis, Th.; Katsifarakis, N.; Konstantinidis, K.; De Vito, S.; Esposito, E.; Smith, P.; André, N.; Gérard, P.; Francis, L. A.; Castell, N.; Schneider, P.; Viana, M.; Minguillón, M. C.; Reimringer, W.; Otjes, R. P.; von Sicard, O.; Pohle, R.; Elen, B.; Suriano, D.; Pfister, V.; Prato, M.; Dipinto, S.; Penza, M.

    2016-12-01

    The 1st EuNetAir Air Quality Joint Intercomparison Exercise organized in Aveiro (Portugal) from 13th-27th October 2014, focused on the evaluation and assessment of environmental gas, particulate matter (PM) and meteorological microsensors, versus standard air quality reference methods through an experimental urban air quality monitoring campaign. The IDAD-Institute of Environment and Development Air Quality Mobile Laboratory was placed at an urban traffic location in the city centre of Aveiro to conduct continuous measurements with standard equipment and reference analysers for CO, NOx, O3, SO2, PM10, PM2.5, temperature, humidity, wind speed and direction, solar radiation and precipitation. The comparison of the sensor data generated by different microsensor-systems installed side-by-side with reference analysers, contributes to the assessment of the performance and the accuracy of microsensor-systems in a real-world context, and supports their calibration and further development. The overall performance of the sensors in terms of their statistical metrics and measurement profile indicates significant differences in the results depending on the platform and on the sensors considered. In terms of pollutants, some promising results were observed for O3 (r2: 0.12-0.77), CO (r2: 0.53-0.87), and NO2 (r2: 0.02-0.89). For PM (r2: 0.07-0.36) and SO2 (r2: 0.09-0.20) the results show a poor performance with low correlation coefficients between the reference and microsensor measurements. These field observations under specific environmental conditions suggest that the relevant microsensor platforms, if supported by the proper post processing and data modelling tools, have enormous potential for new strategies in air quality control.

  2. ICP-MS determination of boron: method optimization during preparation of graphite reference material for boron

    International Nuclear Information System (INIS)

    Granthali, S.K.; Shailaja, P.P.; Mainsha, V.; Venkatesh, K.; Kallola, K.S.; Sanjukta, A.K.

    2017-01-01

    Graphite finds widespread use in nuclear reactors as moderator, reflector, and fuel fabricating components because of its thermal stability and integrity. The manufacturing process consists of various mixing, moulding and baking operations followed by heat-treatment between 2500 °C and 3000 °C. The high temperature treatment is required to drive the amorphous carbon-to-graphite phase transformation. Since synthetic graphite is processed at high temperature, impurity concentrations in the precursor carbon get significantly reduced due to volatilization. However boron may might partly gets converted into boron carbide at high temperatures in the carbon environment of graphite and remains stable (B_4C: boiling point 3500 °C) in the matrix. Literature survey reveals the use of various methods for determination of boron. Previously we have developed a method for determination of boron in graphite electrodes using inductively coupled plasma mass spectrometry (ICP-MS). The method involves removal of graphite matrix by ignition of the sample at 800°C in presence of saturated barium hydroxide solution to prevent the loss of boron. Here we are reporting a modification in the method by using calcium carbonate in place of barium hydroxide and using beryllium (Be) as an internal standard, which resulted in a better precession. The method was validated by spike recovery experiments as well as using another technique viz. Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). The modified method was applied in evaluation of boron concentration in the graphite reference material prepared

  3. Multivariate methods for analysis of environmental reference materials using laser-induced breakdown spectroscopy

    Directory of Open Access Journals (Sweden)

    Shikha Awasthi

    2017-06-01

    Full Text Available Analysis of emission from laser-induced plasma has a unique capability for quantifying the major and minor elements present in any type of samples under optimal analysis conditions. Chemometric techniques are very effective and reliable tools for quantification of multiple components in complex matrices. The feasibility of laser-induced breakdown spectroscopy (LIBS in combination with multivariate analysis was investigated for the analysis of environmental reference materials (RMs. In the present work, different (Certified/Standard Reference Materials of soil and plant origin were analyzed using LIBS and the presence of Al, Ca, Mg, Fe, K, Mn and Si were identified in the LIBS spectra of these materials. Multivariate statistical methods (Partial Least Square Regression and Partial Least Square Discriminant Analysis were employed for quantitative analysis of the constituent elements using the LIBS spectral data. Calibration models were used to predict the concentrations of the different elements of test samples and subsequently, the concentrations were compared with certified concentrations to check the authenticity of models. The non-destructive analytical method namely Instrumental Neutron Activation Analysis (INAA using high flux reactor neutrons and high resolution gamma-ray spectrometry was also used for intercomparison of results of two RMs by LIBS.

  4. Standard Reference Test Method for Making Potentiostatic and Potentiodynamic Anodic Polarization Measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method covers an experimental procedure for checking experimental technique and instrumentation. If followed, this test method will provide repeatable potentiostatic and potentiodynamic anodic polarization measurements that will reproduce data determined by others at other times and in other laboratories provided all laboratories are testing reference samples from the same lot of Type 430 stainless steel. 1.2 Values stated in SI units are to be regarded as the standard. Inch-pound units given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. US EPA CARE Grants

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is a provisional dataset that contains point locations for the subset of Community Action for a Renewed Environment (CARE) grants given out by the US EPA. CARE...

  6. EPA User Personas

    Science.gov (United States)

    Learn how EPA's three web user personas (Information Consumer, Information Intermediary, and Information Interpreter) can help you identify appropriate top audiences and top tasks for a topic or web area.

  7. EPA's Efforts in Eurasia

    Science.gov (United States)

    EPA has been collaborating with Russia, Central Asia, the Caucasus and Ukraine for over 20 years and continues to work with their governments and non-governmental organizations on environment, science and technology issues.

  8. US EPA EJ Grants

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is a provisional dataset that contains point locations for all Environmental Justice (EJ) grants given out by the US EPA. There are many limitations to the data...

  9. EPA Nanorelease Dataset

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPA Nanorelease Dataset. This dataset is associated with the following publication: Wohlleben, W., C. Kingston, J. Carter, E. Sahle-Demessie, S. Vazquez-Campos, B....

  10. Science Inventory | US EPA

    Science.gov (United States)

    The Science Inventory is a searchable database of research products primarily from EPA's Office of Research and Development. Science Inventory records provide descriptions of the product, contact information, and links to available printed material or websites.

  11. EPA Recovery Mapper

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA Recovery Mapper is an Internet interactive mapping application that allows users to discover information about every American Recovery and Reinvestment Act...

  12. EPA Environmental Chemistry Laboratory

    Science.gov (United States)

    1993-01-01

    The Environmental Protection Agency's (EPA) Chemistry Laboratory (ECL) is a national program laboratory specializing in residue chemistry analysis under the jurisdiction of the EPA's Office of Pesticide Programs in Washington, D.C. At Stennis Space Center, the laboratory's work supports many federal anti-pollution laws. The laboratory analyzes environmental and human samples to determine the presence and amount of agricultural chemicals and related substances. Pictured, ECL chemists analyze environmental and human samples for the presence of pesticides and other pollutants.

  13. Measurement of strontium-89 and strontium-90 in environmental waters. A tentative reference method

    International Nuclear Information System (INIS)

    1976-03-01

    A tentative reference method for the measurement of 89 Sr and 90 Sr in environmental waters is described. Samples of environmental water sources are collected, preserved with acid-strontium carrier, and analyzed for 89 Sr and/or 90 Sr. The isotopes are separated from the sample water by precipitating with stable strontium carrier as carbonate. The strontium carbonate is dissolved, 90 Sr separated, the strontium reprecipitated as carbonate, filtered, and counted for the combined 89 Sr and 90 Sr activity. The 90 y is allowed to grow in from the 90 y activity; the strontium carbonate is redissolved; the 90 y is separated, precipitated, and counted for the 90 Sr determination. The 89 Sr activity is then determined by difference of the total 89 Sr and 90 y and the separate 90 Sr activities. Recoveries are determined from the added and found (recovered) strontium carrier. Counting efficiencies are determined with prepared standard reference samples. Results are reported in pCi/liter

  14. Preparation and evaluation of reference materials for accountancy analysis. (1) Preparation and evaluation method

    International Nuclear Information System (INIS)

    Takamatsu, Mai; Kacchi, Tomokazu; Murakami, Toshiki; Ai, Hironobu; Sumi, Mika; Abe, Katsuo; Kageyama, Tomio; Nakazawa, Hiroaki

    2009-01-01

    Isotope dilution mass spectrometry method used for the accountancy analysis at nuclear fuel facilities requires the standard materials called LSD (Large Size Dried) spike. Generally, LSD spikes are prepared from certified reference materials (CRMs) which supplied from foreign laboratories. However, the difficulty of Pu CRM importation is increasing. It is important for safeguards to attain and continue high reliable accountancy analysis and stable securing of LSD spike is essential. Therefore, in order to conserve CRMs, several types of LSD spike were prepared under collaboration work between JAEA and JNFL, such as the amount of nuclear material in one LSD spike is decreased and others. Practical test with actual samples were performed at JNFL Rokkasho reprocessing plant, and those results were compared with the results obtained by using LSD spike which supplied from foreign laboratory. Preparation and verification analysis of LSD spikes and evaluation of uncertainty based on ISO-GUM will be presented. (author)

  15. G-MAPSEQ – a new method for mapping reads to a reference genome

    Directory of Open Access Journals (Sweden)

    Wojciechowski Pawel

    2016-06-01

    Full Text Available The problem of reads mapping to a reference genome is one of the most essential problems in modern computational biology. The most popular algorithms used to solve this problem are based on the Burrows-Wheeler transform and the FM-index. However, this causes some issues with highly mutated sequences due to a limited number of mutations allowed. G-MAPSEQ is a novel, hybrid algorithm combining two interesting methods: alignment-free sequence comparison and an ultra fast sequence alignment. The former is a fast heuristic algorithm which uses k-mer characteristics of nucleotide sequences to find potential mapping places. The latter is a very fast GPU implementation of sequence alignment used to verify the correctness of these mapping positions. The source code of G-MAPSEQ along with other bioinformatic software is available at: http://gpualign.cs.put.poznan.pl.

  16. ANSI/ASHRAE/IES Standard 90.1-2016 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eley, Charles [Eley and Associates, Hobe Sound, FL (United States)

    2017-09-29

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1-2016 (Standard 90.1-2016). The PRM can be used to demonstrate compliance with the standard and to rate the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. Use of the PRM for demonstrating compliance with Standard 90.1 is a new feature of the 2016 edition. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM.

  17. A novel liquid chromatography/tandem mass spectrometry (LC-MS/MS) based bioanalytical method for quantification of ethyl esters of Eicosapentaenoic acid (EPA) and Docosahexaenoic acid (DHA) and its application in pharmacokinetic study.

    Science.gov (United States)

    Viswanathan, Sekarbabu; Verma, P R P; Ganesan, Muniyandithevar; Manivannan, Jeganathan

    2017-07-15

    Omega-3 fatty acids are clinically useful and the two marine omega-3 fatty acids eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) are prevalent in fish and fish oils. Omega-3 fatty acid formulations should undergo a rigorous regulatory step in order to obtain United States Food and Drug Administration (USFDA) approval as prescription drug. In connection with that, despite quantifying EPA and DHA fatty acids, there is a need for quantifying the level of ethyl esters of them in biological samples. In this study, we make use of reverse phase high performance liquid chromatography coupled with mass spectrometry (RP-HPLC-MS)technique for the method development. Here, we have developed a novel multiple reaction monitoring method along with optimized parameters for quantification of EPA and DHA as ethyl esters. Additionally, we attempted to validate the bio-analytical method by conducting the sensitivity, selectivity, precision accuracy batch, carryover test and matrix stability experiments. Furthermore, we also implemented our validated method for evaluation of pharmacokinetics of omega fatty acid ethyl ester formulations. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Description of odd-mass nuclei by multi-reference energy density functional methods

    International Nuclear Information System (INIS)

    Bally, B.

    2014-01-01

    In this work, we are interested in the treatment of odd-mass atomic nuclei in energy density functional (EDF) models. More precisely, the goal of this thesis is to develop and to apply to odd-mass nuclei, the theoretical extensions of the EDF method that are: first, the projection technique, and secondly the configuration mixing by the generator coordinate method (GCM). These two extensions are part of the so-called multi-reference energy density functional (MR-EDF) formalism and allow one to take into account, within an EDF context, the 'beyond-mean-field' correlations between the nucleons forming the nucleus. Until now, the MR-EDF formalism has been applied, in its fully-fledged version, only to the calculation of even-even nuclei. In this thesis, we want to demonstrate the applicability of such a model also for the description of odd-mass nuclei. In the first part of this thesis, we describe the theoretical formalism of the EDF models, giving particular attention to the treatment of symmetries within our approach. In the second part of the manuscript, we apply our model to the nucleus 25 Mg and investigate different aspects of the method (e.g. numerical accuracy, convergence of the configuration mixing, comparison to known experimental data). The results obtained in this work are encouraging and demonstrate the potential of our approach for theoretical nuclear structure calculations. (author)

  19. Formulation of probabilistic models of protein structure in atomic detail using the reference ratio method.

    Science.gov (United States)

    Valentin, Jan B; Andreetta, Christian; Boomsma, Wouter; Bottaro, Sandro; Ferkinghoff-Borg, Jesper; Frellsen, Jes; Mardia, Kanti V; Tian, Pengfei; Hamelryck, Thomas

    2014-02-01

    We propose a method to formulate probabilistic models of protein structure in atomic detail, for a given amino acid sequence, based on Bayesian principles, while retaining a close link to physics. We start from two previously developed probabilistic models of protein structure on a local length scale, which concern the dihedral angles in main chain and side chains, respectively. Conceptually, this constitutes a probabilistic and continuous alternative to the use of discrete fragment and rotamer libraries. The local model is combined with a nonlocal model that involves a small number of energy terms according to a physical force field, and some information on the overall secondary structure content. In this initial study we focus on the formulation of the joint model and the evaluation of the use of an energy vector as a descriptor of a protein's nonlocal structure; hence, we derive the parameters of the nonlocal model from the native structure without loss of generality. The local and nonlocal models are combined using the reference ratio method, which is a well-justified probabilistic construction. For evaluation, we use the resulting joint models to predict the structure of four proteins. The results indicate that the proposed method and the probabilistic models show considerable promise for probabilistic protein structure prediction and related applications. Copyright © 2013 Wiley Periodicals, Inc.

  20. Development of a RIA for clonidine and its comparison with the reference methods

    International Nuclear Information System (INIS)

    Arndts, D.; Staehle, H.; Foerster, H.J.

    1981-01-01

    A radioimmunoassay for clonidine was optimized by introducing, as a tracer ligand, an iodinized clonidine derivative specifically labeled with more than 500 Ci/mMol. The detection limit of clonidine was 10 pg/ml. The high assay specificity was demonstrated by a double isotope technique. The intraassay coefficient of variance (VK) was less than 4% for any concentration, the interassay VK did not exceed 8.3%. The assay reliability was increased when the plasma samples were diluted 1:5, prior to analysis, in normal human blood plasma, which was also used for the preparation of the calibration samples. In a comparative manner, this assay system was subjected to double-blind accuracy control tests, including all other reference methods so far described for clonidine analysis in blood plasma samples. The RIA technique presented here turned out to be the most sensitive and most reliable method, requiring, moreover, the smallest volumes of blood plasma (0.05 ml). This procedure was appropriate for routine tests, since one technician could perform 500 sample analyses a day. The advantages and disadvantages of each method are discussed

  1. A Practical Method for Implementing an Attitude and Heading Reference System

    Directory of Open Access Journals (Sweden)

    Rodrigo Munguía

    2014-04-01

    Full Text Available This paper describes a practical and reliable algorithm for implementing an Attitude and Heading Reference System (AHRS. This kind of system is essential for real time vehicle navigation, guidance and control applications. When low cost sensors are used, efficient and robust algorithms are required for performance to be acceptable. The proposed method is based on an Extended Kalman Filter (EKF in a direct configuration. In this case, the filter is explicitly derived from both the kinematic and error models. The selection of this kind of EKF configuration can help in ensuring a tight integration of the method for its use in filter-based localization and mapping systems in autonomous vehicles. Experiments with real data show that the proposed method is able to maintain an accurate and drift-free attitude and heading estimation. An additional result is to show that there is no ostensible reason for preferring that the filter have an indirect configuration over a direct configuration for implementing an AHRS system.

  2. Development of a quality assured calibration method for the PSI radon chamber reference atmosphere

    International Nuclear Information System (INIS)

    Schuler, C.; Butterweck-Dempewolf, G.; Vezzu, G.

    1997-01-01

    Radon detectors and measuring instruments are calibrated at the PSI Reference Laboratory for Radon Gas Concentration Measurements by exposing them to a calibrated radon reference atmosphere in the PSI radon chamber. A sophisticated and quality assured calibration technique was developed which guarantees the traceability of this radon chamber reference atmosphere to standards of internationally acknowledged primary laboratories. (author) 2 figs., 2 refs

  3. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2014-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 4 février de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org. * * * * * Carte de membre de l'Association du personnel du CERN Les membres GAC-EPA qui souhaitent recevoir une carte de membre AP en 2014 doivent  en faire la demande par email à secretariat@gac-epa.org, ou par lettre au secrétaire ...

  4. 76 FR 9780 - Notification of Deletion of System of Records; EPA Parking Control Office File (EPA-10) and EPA...

    Science.gov (United States)

    2011-02-22

    ... System of Records; EPA Parking Control Office File (EPA-10) and EPA Transit and Guaranteed Ride Home... Environmental Protection Agency (EPA) is deleting the systems of records for EPA Parking Control Office File... through the EPA Internet under the ``Federal Register'' listings at http://www.epa.gov/fedrgstr/ . Dated...

  5. Recent advances in ratio primary reference measurement procedures (definitive methods) and their use in certification of reference materials and controlling assigned values in proficiency testing

    International Nuclear Information System (INIS)

    Dybczyñski, R.S.; Polkowska-Motrenko, H.; Chajduk, E.; Danko, B.; Pyszynska, M.

    2014-01-01

    The idea of definitive methods based on radiochemical neutron activation analysis (RNAA), consists in combination of neutron activation with the highly selective and quantitative post-irradiation isolation of the desired radionuclide by column chromatography followed by γ-ray spectrometric measurement. The principles of construction of such methods, which were devised in the Institute of Nuclear Chemistry and Technology, are reminded and the significance of these methods for analytical quality assurance is emphasized. According to VIM 3 nomenclature these methods may be called: ratio primary reference measurement procedures (RPRMPs). RPRMP for the determination of Se is briefly presented and its use for checking the accuracy of 'assigned values' established by expert laboratories in some proficiency tests, is demonstrated

  6. Assessing Crowdsourced POI Quality: Combining Methods Based on Reference Data, History, and Spatial Relations

    Directory of Open Access Journals (Sweden)

    Guillaume Touya

    2017-03-01

    Full Text Available With the development of location-aware devices and the success and high use of Web 2.0 techniques, citizens are able to act as sensors by contributing geographic information. In this context, data quality is an important aspect that should be taken into account when using this source of data for different purposes. The goal of the paper is to analyze the quality of crowdsourced data and to study its evolution over time. We propose two types of approaches: (1 use the intrinsic characteristics of the crowdsourced datasets; or (2 evaluate crowdsourced Points of Interest (POIs using external datasets (i.e., authoritative reference or other crowdsourced datasets, and two different methods for each approach. The potential of the combination of these approaches is then demonstrated, to overcome the limitations associated with each individual method. In this paper, we focus on POIs and places coming from the very successful crowdsourcing project: OpenStreetMap. The results show that the proposed approaches are complementary in assessing data quality. The positive results obtained for data matching show that the analysis of data quality through automatic data matching is possible but considerable effort and attention are needed for schema matching given the heterogeneity of OSM and the representation of authoritative datasets. For the features studied, it can be noted that change over time is sometimes due to disagreements between contributors, but in most cases the change improves the quality of the data.

  7. A Novel Real-Time Reference Key Frame Scan Matching Method

    Directory of Open Access Journals (Sweden)

    Haytham Mohamed

    2017-05-01

    Full Text Available Unmanned aerial vehicles represent an effective technology for indoor search and rescue operations. Typically, most indoor missions’ environments would be unknown, unstructured, and/or dynamic. Navigation of UAVs in such environments is addressed by simultaneous localization and mapping approach using either local or global approaches. Both approaches suffer from accumulated errors and high processing time due to the iterative nature of the scan matching method. Moreover, point-to-point scan matching is prone to outlier association processes. This paper proposes a low-cost novel method for 2D real-time scan matching based on a reference key frame (RKF. RKF is a hybrid scan matching technique comprised of feature-to-feature and point-to-point approaches. This algorithm aims at mitigating errors accumulation using the key frame technique, which is inspired from video streaming broadcast process. The algorithm depends on the iterative closest point algorithm during the lack of linear features which is typically exhibited in unstructured environments. The algorithm switches back to the RKF once linear features are detected. To validate and evaluate the algorithm, the mapping performance and time consumption are compared with various algorithms in static and dynamic environments. The performance of the algorithm exhibits promising navigational, mapping results and very short computational time, that indicates the potential use of the new algorithm with real-time systems.

  8. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2015-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 3 mars de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 7 avril, 5 mai, 2 juin, 1er septembre, 6 octobre, 3 novembre et 1er décembre 2013. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  9. GAC-EPA

    CERN Document Server

    GAC-EPA

    2013-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 1er octobre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 5 novembre et 3 décembre 2013. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  10. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 5 avril de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 3 mai, 7 juin, 6 septembre, 4 octobre, 1er et 29 novembre décembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  11. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : le mardi 29 novembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  12. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : le mardi 1er novembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel. La permanence suivante aura lieu le mardi 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  13. GAC-EPA

    CERN Document Server

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 3 mai de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 7 juin, 6 septembre, 4 octobre, 1er et 29 novembre décembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  14. GAC-EPA

    CERN Document Server

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 5 avril de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 3 mai, 7 juin, 6 septembre, 4 octobre, 1er et 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  15. GAC-EPA

    CERN Document Server

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 4 octobre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 1er et 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  16. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2015-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 1er décembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  17. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 2 février de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 1er mars, 5 avril, 3 mai, 7 juin, 6 septembre, 4 octobre, 1er et 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  18. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 1er mars de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 5 avril, 3 mai, 7 juin, 6 septembre, 4 octobre, 1er et 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  19. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2015-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 3 novembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel La permanence suivante aura lieu le mardi 1er décembre 2015. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  20. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2013-01-01

    Carte de membre de l'Association du personnel du CERN Comme cela a été précisé dans le bulletin d'automne n° 43, les membres GAC-EPA qui souhaitent recevoir une carte de membre AP en 2013 devront en faire la demande, avant le 31 janvier, par email à secretariat@gac-epa.org, ou par lettre au secrétaire du GAC-EPA, p/a Association du personnel CERN, CH-1211 GENEVE 23. Il n'y a pas de tacite reconduction de ces cartes et par conséquent une demande doit être faite chaque année par l'intéressé(e).

  1. Development of a new certified reference material of diosgenin using mass balance approach and Coulometric titration method.

    Science.gov (United States)

    Gong, Ningbo; Zhang, Baoxi; Hu, Fan; Du, Hui; Du, Guanhua; Gao, Zhaolin; Lu, Yang

    2014-12-01

    Certified reference materials (CRMs) can be used as a valuable tool to validate the trueness of measurement methods and to establish metrological traceability of analytical results. Diosgenin has been selected as a candidate reference material. Characterization of the material relied on two different methods, mass balance method and Coulometric titration method (CT). The certified value of diosgenin CRM is 99.80% with an expanded uncertainty of 0.37% (k=2). The new CRM of diosgenin can be used to validate analytical methods, improve the accuracy of measurement data and control the quality of diosgenin in relevant pharmaceutical formulations. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. The effects of user factors and symbol referents on public symbol design using the stereotype production method.

    Science.gov (United States)

    Ng, Annie W Y; Siu, Kin Wai Michael; Chan, Chetwyn C H

    2012-01-01

    This study investigated the influence of user factors and symbol referents on public symbol design among older people, using the stereotype production method for collecting user ideas during the symbol design process. Thirty-one older adults were asked to draw images based on 28 public symbol referents and to indicate their familiarity with and ease with which they visualised each referent. Differences were found between the pictorial solutions generated by males and females. However, symbol design was not influenced by participants' education level, vividness of visual imagery, object imagery preference or spatial imagery preference. Both familiar and unfamiliar referents were illustrated pictorially without much difficulty by users. The more visual the referent, the less difficulty the users had in illustrating it. The findings of this study should aid the optimisation of the stereotype production method for user-involved symbol design. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  3. Efficacy of Ballast Water Treatment Systems: A Report by the EPA Science Advisory Board

    Science.gov (United States)

    2011-07-12

    followed during testing, are needed. In addition, the EPA 3 Protists refers to various one-celled...should develop metrics and methods appropriate for compliance monitoring and enforcement as soon as possible. Limits for selected protists < 10 µm...as “ protist -sized” organisms, or organisms ≥10 µm and < 50 µm in minimum dimension), and the ETV Protocol provides examples with a more stringent

  4. Experimental validation of the buildings energy performance (PEC assessment methods with reference to occupied spaces heating

    Directory of Open Access Journals (Sweden)

    Cristian PETCU

    2010-01-01

    provided by measurements and to those provided by the monthly calculation (NP 048-2006. The deviations of 1.45% and 2.2% respectively validate the hourly calculation model, as they actually have no physical significance. The report presents a phenomenological analysis of the building transfer functions synthesized as tev (τ, functions which attest their phenomenological objectivity in macro and hourly terms. The case studies completing the calculation models experimental validation emphasize unacceptably large differences between the results provided by the use of standardized calculation methods (Mc 001 / 2-2006 and SR EN 13790:2009 and those specific to the methods referred to in this report, experimentally validated.

  5. Pregnancy and variations of carbohydrate-deficient transferrin levels measured by the candidate reference HPLC method.

    Science.gov (United States)

    Bianchi, Vincenza; Ivaldi, Alessandra; Raspagni, Alessia; Arfini, Carlo; Vidali, Matteo

    2011-01-01

    Contrasting data are available on the diagnostic accuracy of carbohydrate-deficient transferrin (CDT) during pregnancy. These differences may depend in part on how CDT was evaluated and expressed. Here, we report on variations of CDT levels in pregnant women using the high performance liquid chromatography (HPLC) candidate reference method. Alanine aminotransferase, aspartate aminotransferase, gamma-glutamyltransferase, mean corpuscular volume, serum transferrin, urine and serum ethyl glucuronide and CDT were measured in 64 women, self-reporting as non-alcohol abusers (age: median 34, IQR: 28-38), at different stages of normal pregnancy (gestational weeks: median 28, IQR: 8-33). CDT was expressed as percentage of disialotransferrin to total transferrin (%CDT). Transferrin was associated with both %CDT (r = 0.66; P pregnancy trimester (first trimester: mean 1.01% (SD 0.19); second trimester: 1.30% (SD 0.14); third trimester: 1.53% (SD 0.22); ANOVA P pregnancy trimesters (P pregnancy and CDT could be more complex. The diagnostic accuracy of CDT for detecting alcohol abuse in a legal context may be limited in pregnant women and the effect of gestational age should be considered.

  6. Trace elements determination in silicon and ferrosilicon reference materials by instrumental neutron activation analysis method

    International Nuclear Information System (INIS)

    Moreira, Edson Goncalves; Vasconcellos, Marina Beatriz Agostini; Saiki, Mitiko; Iamashita, Celia Omine

    2002-01-01

    The use of certified reference materials, CRM, is of uppermost importance in the rastreability realization of the measurement process. At times, CRM use is restricted by the non existence of a suitable CRM with similarity to the sample in respect to matrix composition or with element levels in different orders of magnitude. IPT Chemical Division launched a project to prepare a metallic silicon CRM, due to the requirements of the industries in this field. To characterize this new CRM, IPEN Nuclear Reactor Center is able to perform instrumental neutron activation analysis, INAA, a very suitable method for silicon matrix samples because they produce basically the short lived radionuclide 3 1 Si under thermal neutrons flux, which after radioactive decay, does not interfere in the determination of other elements. In this paper, it is presented the determination of As, Br, Co, Cr, K, Eu, Fe, La, Mn, Na Nb, Sb, Sm, Sc, Th, Tb, U, V, W and Yb in silicon CRM NBS SRM 57; ferrosilicon CRM IPT 56; IPT 70; NBS SRM 58a; NBS SRM 59a and silicon RM under preparation IPT 132. From the results, the accuracy and the precision of the process were assessed. (author)

  7. Standard test method for determination of reference temperature, to, for ferritic steels in the transition range

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of a reference temperature, To, which characterizes the fracture toughness of ferritic steels that experience onset of cleavage cracking at elastic, or elastic-plastic KJc instabilities, or both. The specific types of ferritic steels (3.2.1) covered are those with yield strengths ranging from 275 to 825 MPa (40 to 120 ksi) and weld metals, after stress-relief annealing, that have 10 % or less strength mismatch relative to that of the base metal. 1.2 The specimens covered are fatigue precracked single-edge notched bend bars, SE(B), and standard or disk-shaped compact tension specimens, C(T) or DC(T). A range of specimen sizes with proportional dimensions is recommended. The dimension on which the proportionality is based is specimen thickness. 1.3 Median KJc values tend to vary with the specimen type at a given test temperature, presumably due to constraint differences among the allowable test specimens in 1.2. The degree of KJc variability among specimen types i...

  8. EPA Web Training Classes

    Science.gov (United States)

    Scheduled webinars can help you better manage EPA web content. Class topics include Drupal basics, creating different types of pages in the WebCMS such as document pages and forms, using Google Analytics, and best practices for metadata and accessibility.

  9. EPA's Green Roof Research

    Science.gov (United States)

    This is a presentation on the basics of green roof technology. The presentation highlights some of the recent ORD research projects on green roofs and provices insight for the end user as to the benefits for green roof technology. It provides links to currently available EPA re...

  10. A Complementary Isothermal Amplification Method to the U.S. EPA Quantitative Polymerase Chain Reaction Approach for the Detection of Enterococci in Environmental Waters.

    Science.gov (United States)

    Kolm, Claudia; Martzy, Roland; Brunner, Kurt; Mach, Robert L; Krska, Rudolf; Heinze, Georg; Sommer, Regina; Reischer, Georg H; Farnleitner, Andreas H

    2017-06-20

    We report a novel molecular assay, based on helicase-dependent amplification (HDA), for the detection of enterococci as markers for fecal pollution in water. This isothermal assay targets the same Enterococcus 23S rRNA gene region as the existing quantitative polymerase chain reaction (qPCR) assays of U.S. Environmental Protection Agency Methods 1611 and 1609 but can be entirely performed on a simple heating block. The developed Enterococcus HDA assay successfully discriminated 15 enterococcal from 15 non-enterococcal reference strains and reliably detected 48 environmental isolates of enterococci. The limit of detection was 25 target copies per reaction, only 3 times higher than that of qPCR. The applicability of the assay was tested on 30 environmental water sample DNA extracts, simulating a gradient of fecal pollution. Despite the isothermal nature of the reaction, the HDA results were consistent with those of the qPCR reference. Given this performance, we conclude that the developed Enterococcus HDA assay has great potential as a qualitative molecular screening method for resource-limited settings when combined with compatible up- and downstream processes. This amplification strategy can pave the way for developing a new generation of rapid, low-cost, and field-deployable molecular diagnostic tools for water quality monitoring.

  11. Evaluation of reference evapotranspiration methods for the northeastern region of India

    Directory of Open Access Journals (Sweden)

    Pankaj K. Pandey

    2016-03-01

    Full Text Available The study planed to identify a suitable alternative to the FAO-56 Penman-Monteith (FAO56PM equation for calculating reference evapotranspiration (ET0 from chosen temperature and radiation based models utilizing monthly meteorological data from 30 destinations in diverse agro-ecological regions of the Northeast (NE India i.e., Assam Bengal Plain (ABP, eastern Himalaya (EH, and the northeastern hilly (NEH region. Radiation-based IRMAK3 most appropriate in the ABP (weighted root mean square deviation, WRMSD=0.17 mm d−1, r2=0.98, for Nagrakata, and TURC model being in the first three rank of most of the sites, with the lowest error and highest correlation in NEH (WRMSD=0.10 mm d−1, r2=0.92, for Shillong, and EH (WRMSD=0.23 mm d−1, r2=0.95, for Gangtok. Findings reveal that IRMAK3 and TURC models performed equally well and were observed to be the best among selected models for the majority of stations followed by FAO24 Blaney-Criddle (FAO24BC, and 1957MAKK. Pair-wise regression equations were developed for preferred FAO56PM ET0 estimates to ET0 estimates by alternative methods. Cross-correlation of eighteen chose methods demonstrated that the five equations (i.e. four radiation- and one temperature-based performed exceptionally well when contrasted with the FAO56PM model, thus being advised for assessing ET0 under limiting data conditions as have yielded a better estimate of ET0 with a small error.

  12. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. I. A review of Kjeldahl methods adopted by laboratory medicine.

    Science.gov (United States)

    Chromý, Vratislav; Vinklárková, Bára; Šprongl, Luděk; Bittová, Miroslava

    2015-01-01

    We found previously that albumin-calibrated total protein in certified reference materials causes unacceptable positive bias in analysis of human sera. The simplest way to cure this defect is the use of human-based serum/plasma standards calibrated by the Kjeldahl method. Such standards, commutative with serum samples, will compensate for bias caused by lipids and bilirubin in most human sera. To find a suitable primary reference procedure for total protein in reference materials, we reviewed Kjeldahl methods adopted by laboratory medicine. We found two methods recommended for total protein in human samples: an indirect analysis based on total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. The methods found will be assessed in a subsequent article.

  13. EPA Communications Stylebook: Writing Guide

    Science.gov (United States)

    For the most part, EPA follows the Associated Press (AP) Stylebook. Other requirements of basic punctuation and grammar and usage in EPA writing modify, supplement, or in some cases reiterate AP style.

  14. EPA Alternative Dispute Resolution Contacts

    Science.gov (United States)

    The success of EPA's ADR efforts depends on a network of talented and experienced professionals in Headquarters offices and EPA Regions. For Agency-wide ADR information, please contact the Conflict Prevention and Resolution Center.

  15. Long-term response to genomic selection: effects of estimation method and reference population structure for different genetic architectures.

    Science.gov (United States)

    Bastiaansen, John W M; Coster, Albart; Calus, Mario P L; van Arendonk, Johan A M; Bovenhuis, Henk

    2012-01-24

    Genomic selection has become an important tool in the genetic improvement of animals and plants. The objective of this study was to investigate the impacts of breeding value estimation method, reference population structure, and trait genetic architecture, on long-term response to genomic selection without updating marker effects. Three methods were used to estimate genomic breeding values: a BLUP method with relationships estimated from genome-wide markers (GBLUP), a Bayesian method, and a partial least squares regression method (PLSR). A shallow (individuals from one generation) or deep reference population (individuals from five generations) was used with each method. The effects of the different selection approaches were compared under four different genetic architectures for the trait under selection. Selection was based on one of the three genomic breeding values, on pedigree BLUP breeding values, or performed at random. Selection continued for ten generations. Differences in long-term selection response were small. For a genetic architecture with a very small number of three to four quantitative trait loci (QTL), the Bayesian method achieved a response that was 0.05 to 0.1 genetic standard deviation higher than other methods in generation 10. For genetic architectures with approximately 30 to 300 QTL, PLSR (shallow reference) or GBLUP (deep reference) had an average advantage of 0.2 genetic standard deviation over the Bayesian method in generation 10. GBLUP resulted in 0.6% and 0.9% less inbreeding than PLSR and BM and on average a one third smaller reduction of genetic variance. Responses in early generations were greater with the shallow reference population while long-term response was not affected by reference population structure. The ranking of estimation methods was different with than without selection. Under selection, applying GBLUP led to lower inbreeding and a smaller reduction of genetic variance while a similar response to selection was

  16. Experimental data of Se and B released from FGDG, soil and soil-FGDG mixture in EPA-Method 1314 and optimization of fate and transport model simulation results of Se and B leaching from FGDG in an agricultural field and a landfill.

    Data.gov (United States)

    U.S. Environmental Protection Agency — The leachate concentrations of Se and B released from FGDG, soil and soil-FGDG mixture obtained from EPA-method 1314 is included in the data set. The non-equilibrium...

  17. Normalization Methods and Selection Strategies for Reference Materials in Stable Isotope Analyes. Review

    Energy Technology Data Exchange (ETDEWEB)

    Skrzypek, G. [West Australian Biogeochemistry Centre, John de Laeter Centre of Mass Spectrometry, School of Plant Biology, University of Western Australia, Crawley (Australia); Sadler, R. [School of Agricultural and Resource Economics, University of Western Australia, Crawley (Australia); Paul, D. [Department of Civil Engineering (Geosciences), Indian Institute of Technology Kanpur, Kanpur (India); Forizs, I. [Institute for Geochemical Research, Hungarian Academy of Sciences, Budapest (Hungary)

    2013-07-15

    Stable isotope ratio mass spectrometers are highly precise, but not accurate instruments. Therefore, results have to be normalized to one of the isotope scales (e.g., VSMOW, VPDB) based on well calibrated reference materials. The selection of reference materials, numbers of replicates, {delta}-values of these reference materials and normalization technique have been identified as crucial in determining the uncertainty associated with the final results. The most common normalization techniques and reference materials have been tested using both Monte Carlo simulations and laboratory experiments to investigate aspects of error propagation during the normalization of isotope data. The range of observed differences justifies the need to employ the same sets of standards worldwide for each element and each stable isotope analytical technique. (author)

  18. A method to obtain reference images for evaluation of ultrasonic tissue characterization techniques

    DEFF Research Database (Denmark)

    Jensen, M.S.; Wilhjelm, Jens E.; Sahl, B.

    2002-01-01

    of the macroscopic photograph, due to the histological preparation process. The histological information was "mapped back" into the format of the ultrasound images the following way: On the macroscopic images, outlines were drawn manually which defined the border of the tissue. These outlines were superimposed...... of the various tissue types. Specifically, the macroscopic image revealed the borders between the different tissues, while the histological image identified the four tissue types. A set of 12 reference images based on modified macroscopic outlines was created. The overlap between the ultrasound images...... and the macroscopic images-which are the geometrical basis for the final reference images-was between 77% and 93%. A set of 12 reference images spaced 2.5 mm, identifying spatial location of four different tissue types in porcine muscle has been created. With the reference images, it is possible to quantitatively...

  19. Synthesized view comparison method for no-reference 3D image quality assessment

    Science.gov (United States)

    Luo, Fangzhou; Lin, Chaoyi; Gu, Xiaodong; Ma, Xiaojun

    2018-04-01

    We develop a no-reference image quality assessment metric to evaluate the quality of synthesized view rendered from the Multi-view Video plus Depth (MVD) format. Our metric is named Synthesized View Comparison (SVC), which is designed for real-time quality monitoring at the receiver side in a 3D-TV system. The metric utilizes the virtual views in the middle which are warped from left and right views by Depth-image-based rendering algorithm (DIBR), and compares the difference between the virtual views rendered from different cameras by Structural SIMilarity (SSIM), a popular 2D full-reference image quality assessment metric. The experimental results indicate that our no-reference quality assessment metric for the synthesized images has competitive prediction performance compared with some classic full-reference image quality assessment metrics.

  20. A NEW APPROACH FOR CULTURING LEMNA MINOR (DUCKWEED) AND STANDARDIZED METHOD FOR USING ATRAZINE AS A REFERENCE TOXICANT

    Science.gov (United States)

    Lemna minor (Duckweed) is commonly used in aquatic toxicity investigations. Methods for culturing and testing with reference toxicants, such as atrazine, are somewhat variable among researchers. Our goal was to develop standardized methods of culturing and testing for use with L....

  1. A method of camera calibration in the measurement process with reference mark for approaching observation space target

    Science.gov (United States)

    Zhang, Hua; Zeng, Luan

    2017-11-01

    Binocular stereoscopic vision can be used for space-based space targets near observation. In order to solve the problem that the traditional binocular vision system cannot work normally after interference, an online calibration method of binocular stereo measuring camera with self-reference is proposed. The method uses an auxiliary optical imaging device to insert the image of the standard reference object into the edge of the main optical path and image with the target on the same focal plane, which is equivalent to a standard reference in the binocular imaging optical system; When the position of the system and the imaging device parameters are disturbed, the image of the standard reference will change accordingly in the imaging plane, and the position of the standard reference object does not change. The camera's external parameters can be re-calibrated by the visual relationship of the standard reference object. The experimental results show that the maximum mean square error of the same object can be reduced from the original 72.88mm to 1.65mm when the right camera is deflected by 0.4 degrees and the left camera is high and low with 0.2° rotation. This method can realize the online calibration of binocular stereoscopic vision measurement system, which can effectively improve the anti - jamming ability of the system.

  2. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 1er novembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel La permanence suivante aura lieu le mardi 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php  

  3. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 31 octobre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel La permanence suivante aura lieu le mardi 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  4. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 29 août de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php  

  5. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 28 novembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  6. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 30 mai de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  7. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 26 septembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  8. EPA's Radioactive Source Program

    International Nuclear Information System (INIS)

    Kopsick, D.

    2004-01-01

    The US EPA is the lead Federal agency for emergency responses to unknown radiological materials, not licensed, owned or operated by a Federal agency or an Agreement state (Federal Radiological Emergency Response Plan, 1996). The purpose of EPA's clean materials programme is to keep unwanted and unregulated radioactive material out of the public domain. This is achieved by finding and securing lost sources, maintaining control of existing sources and preventing future losses. The focus is on both, domestic and international fronts. The domestic program concentrates on securing lost sources, preventing future losses, alternative technologies like tagging of radioactive sources in commerce, pilot radioactive source roundup, training programs, scrap metal and metal processing facilities, the demolition industry, product stewardship and alternatives to radioactive devices (fewer radioactive source devices means fewer orphan sources). The international program consists of securing lost sources, preventing future losses, radiation monitoring of scrap metal at ports and the international scrap metal monitoring protocol

  9. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 31 janvier de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 28 février, 28 mars, 25 avril, 30 mai, 29 août, 26 septembre, 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  10. Determination of Methyl tert-Butyl Ether and tert-Butyl Alcohol in Water by Solid-Phase Microextraction/Head Space Analysis in Comparison to EPA Method 5030/8260B

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Keun-Chan; Stringfellow, William T.

    2003-10-02

    Methyl tert-butyl ether (MTBE) is now one of the most common groundwater contaminants in the United States. Groundwater contaminated with MTBE is also likely to be contaminated with tert-butyl alcohol (TBA), because TBA is a component of commercial grade MTBE, TBA can also be used as a fuel oxygenate, and TBA is a biodegradation product of MTBE. In California, MTBE is subject to reporting at concentrations greater than 3 {micro}g/L. TBA is classified as a ''contaminant of current interest'' and has a drinking water action level of 12 {micro}g/L. In this paper, we describe the development and optimization of a simple, automated solid phase microextraction (SPME) method for the analysis of MTBE and TBA in water and demonstrate the applicability of this method for monitoring MTBE and TBA contamination in groundwater, drinking water, and surface water. In this method, the headspace (HS) of a water sample is extracted with a carboxen/polydimethylsiloxane SPME fiber, the MTBE and TBA are desorbed into a gas chromatograph (GC), and detected using mass spectrometry (MS). The method is optimized for the routine analysis of MTBE and TBA with a level of quantitation of 0.3 {micro}g/L and 4 {micro}g/L, respectively, in water. MTBE quantitation was linear for over two orders of concentration (0.3 {micro}g/L -80 {micro}g/L). TBA was found to be linear within the range of 4 {micro}g/L-7,900 {micro}g/L. The lower level of detection for MTBE is 0.03 {micro}g/L using this method. This SPME method using headspace extraction was found to be advantageous over SPME methods requiring immersion of the fiber into the water samples, because it prolonged the life of the fiber by up to 400 sample analyses. This is the first time headspace extraction SPME has been shown to be applicable to the measurement of both MTBE and TBA at concentrations below regulatory action levels. This method was compared with the certified EPA Method 5030/8260B (purge-and-trap/GC/MS) using split

  11. The relation between the omega-3 index and arachidonic acid is bell shaped : Synergistic at low EPA plus DHA status and antagonistic at high EPA plus DHA status

    NARCIS (Netherlands)

    Luxwolda, Martine F.; Kuipers, Remko S.; Smit, Ella N.; Velzing-Aarts, Francien V.; Dijck-Brouwer, D. A. Janneke; Muskiet, Frits A. J.

    2011-01-01

    Introduction: The relation between docosahexaenoic (DHA) and eicosapentaenoic (EPA) vs. arachidonic acid (AA) seems characterized by both synergism and antagonism. Materials and methods: Investigate the relation between EPA + DHA and AA in populations with a wide range of EPA + DHA status and across

  12. De novo clustering methods outperform reference-based methods for assigning 16S rRNA gene sequences to operational taxonomic units

    Directory of Open Access Journals (Sweden)

    Sarah L. Westcott

    2015-12-01

    Full Text Available Background. 16S rRNA gene sequences are routinely assigned to operational taxonomic units (OTUs that are then used to analyze complex microbial communities. A number of methods have been employed to carry out the assignment of 16S rRNA gene sequences to OTUs leading to confusion over which method is optimal. A recent study suggested that a clustering method should be selected based on its ability to generate stable OTU assignments that do not change as additional sequences are added to the dataset. In contrast, we contend that the quality of the OTU assignments, the ability of the method to properly represent the distances between the sequences, is more important.Methods. Our analysis implemented six de novo clustering algorithms including the single linkage, complete linkage, average linkage, abundance-based greedy clustering, distance-based greedy clustering, and Swarm and the open and closed-reference methods. Using two previously published datasets we used the Matthew’s Correlation Coefficient (MCC to assess the stability and quality of OTU assignments.Results. The stability of OTU assignments did not reflect the quality of the assignments. Depending on the dataset being analyzed, the average linkage and the distance and abundance-based greedy clustering methods generated OTUs that were more likely to represent the actual distances between sequences than the open and closed-reference methods. We also demonstrated that for the greedy algorithms VSEARCH produced assignments that were comparable to those produced by USEARCH making VSEARCH a viable free and open source alternative to USEARCH. Further interrogation of the reference-based methods indicated that when USEARCH or VSEARCH were used to identify the closest reference, the OTU assignments were sensitive to the order of the reference sequences because the reference sequences can be identical over the region being considered. More troubling was the observation that while both USEARCH and

  13. A pilot effectiveness study of the Enhancing Parenting Skills (EPaS) 2014 programme for parents of children with behaviour problems: study protocol for a randomised controlled trial

    OpenAIRE

    Williams, Margiad Elen; Hutchings, Judy

    2015-01-01

    Background The Enhancing Parenting Skills (EPaS) 2014 programme is a home-based, health visitor-delivered parenting support programme for parents of children with identified behaviour problems. This trial aims to evaluate the effectiveness of the EPaS 2014 programme compared to a waiting-list treatment as usual control group. Methods/Design This is a pragmatic, multicentre randomised controlled trial. Sixty health visitors will each be asked to identify two families that have a child scoring ...

  14. Help! A simple method for getting back-up help to the reference desk

    Directory of Open Access Journals (Sweden)

    Kenneth Furuta

    2008-03-01

    Full Text Available Using the "net send" command, native to Windows XP, librarians at the University of California, Riverside created a "help button" for the reference desk. The simple script file sends a message to librarians' workstations in their offices and logs the date and time of use. This paper describes that program.

  15. Procedures for EPA Libraries to Obtain Materials through Interlibrary Loan/Document Delivery

    Science.gov (United States)

    The purpose of this document is to establish Agency-wide procedures by which EPA libraries obtain materials for Agency employees and authorized EPA contractors through interlibrary loan (ILL) and other document delivery methods.

  16. Reference test methods for total water in lint cotton by Karl Fischer Titration and low temperature distillation

    Science.gov (United States)

    In a study of comparability of total water contents (%) of conditioned cottons by Karl Fischer Titration (KFT) and Low Temperature Distillation (LTD) reference methods, we demonstrated a match of averaged results based on a large number of replications and weighing the test specimens at the same tim...

  17. SPM analysis of parametric (R)-[11C]PK11195 binding images: plasma input versus reference tissue parametric methods

    NARCIS (Netherlands)

    Schuitemaker, Alie; van Berckel, Bart N. M.; Kropholler, Marc A.; Veltman, Dick J.; Scheltens, Philip; Jonker, Cees; Lammertsma, Adriaan A.; Boellaard, Ronald

    2007-01-01

    (R)-[11C]PK11195 has been used for quantifying cerebral microglial activation in vivo. In previous studies, both plasma input and reference tissue methods have been used, usually in combination with a region of interest (ROI) approach. Definition of ROIs, however, can be labourious and prone to

  18. A study on the optimization of referring method about medical images using MIH (Medical Image History)

    International Nuclear Information System (INIS)

    Kim, Sun Chil; Kim, Jung Min

    2002-01-01

    The recent development of embodiment technology of the medical images makes most medical institutions introduce PACS (Picture Archiving and Communication System) in haste. However lots of PACS solutions, currently developed and distributed, haven't been able to serve the convenience of users and to satisfy user's demand because of economic limitations and administrator-oriented con-siderations in the process of development. So we have developed MIH (Medical Image History), by which we can search and refer to the patient's medical images and information with few restrictions of time and space for diagnosis and treatment. The program will contribute to the improvement in the medical environment and meet the clients' need. We'll make more effort to develop the application which insures the better quality of medical images. MIH manages the patient's image files and medical records like film chart in connection with time. This trial will contribute to the reduction of the economical loss caused by unnecessary references and improve the quality in the medical services. The demand on the development of the program which refers to the medical data quickly and keeps them stable will be continued by the medical institute. This will satisfy the client's demand and improve the service to the patients in that the program will be modified from the standpoint of the users. MIH is trying to keep user-oriented policy and to apply the benefit of the analog system to the digital environment. It is necessary to lead the public to the better understanding that the systematic management and referring of the medical images is as important as the quality of the images

  19. A study on the optimization of referring method about medical images using MIH (Medical Image History)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Chil; Kim, Jung Min [College of Health Sciences, Korea University, Seoul (Korea, Republic of)

    2002-09-15

    The recent development of embodiment technology of the medical images makes most medical institutions introduce PACS (Picture Archiving and Communication System) in haste. However lots of PACS solutions, currently developed and distributed, haven't been able to serve the convenience of users and to satisfy user's demand because of economic limitations and administrator-oriented con-siderations in the process of development. So we have developed MIH (Medical Image History), by which we can search and refer to the patient's medical images and information with few restrictions of time and space for diagnosis and treatment. The program will contribute to the improvement in the medical environment and meet the clients' need. We'll make more effort to develop the application which insures the better quality of medical images. MIH manages the patient's image files and medical records like film chart in connection with time. This trial will contribute to the reduction of the economical loss caused by unnecessary references and improve the quality in the medical services. The demand on the development of the program which refers to the medical data quickly and keeps them stable will be continued by the medical institute. This will satisfy the client's demand and improve the service to the patients in that the program will be modified from the standpoint of the users. MIH is trying to keep user-oriented policy and to apply the benefit of the analog system to the digital environment. It is necessary to lead the public to the better understanding that the systematic management and referring of the medical images is as important as the quality of the images.

  20. Efficient speed control of induction motor using RBF based model reference adaptive control method

    OpenAIRE

    Kilic, Erdal; Ozcalik, Hasan Riza; Yilmaz, Saban

    2017-01-01

    This paper proposes a model reference adaptive speed controller based on artificial neural network for induction motor drives. The performance of traditional feedback controllers has been insufficient in speed control of induction motors due to nonlinear structure of the system, changing environmental conditions, and disturbance input effects. A successful speed control of induction motor requires a nonlinear control system. On the other hand, in recent years, it has been demonstrated that ar...

  1. A novel SNP analysis method to detect copy number alterations with an unbiased reference signal directly from tumor samples

    Directory of Open Access Journals (Sweden)

    LaFramboise William A

    2011-01-01

    Full Text Available Abstract Background Genomic instability in cancer leads to abnormal genome copy number alterations (CNA as a mechanism underlying tumorigenesis. Using microarrays and other technologies, tumor CNA are detected by comparing tumor sample CN to normal reference sample CN. While advances in microarray technology have improved detection of copy number alterations, the increase in the number of measured signals, noise from array probes, variations in signal-to-noise ratio across batches and disparity across laboratories leads to significant limitations for the accurate identification of CNA regions when comparing tumor and normal samples. Methods To address these limitations, we designed a novel "Virtual Normal" algorithm (VN, which allowed for construction of an unbiased reference signal directly from test samples within an experiment using any publicly available normal reference set as a baseline thus eliminating the need for an in-lab normal reference set. Results The algorithm was tested using an optimal, paired tumor/normal data set as well as previously uncharacterized pediatric malignant gliomas for which a normal reference set was not available. Using Affymetrix 250K Sty microarrays, we demonstrated improved signal-to-noise ratio and detected significant copy number alterations using the VN algorithm that were validated by independent PCR analysis of the target CNA regions. Conclusions We developed and validated an algorithm to provide a virtual normal reference signal directly from tumor samples and minimize noise in the derivation of the raw CN signal. The algorithm reduces the variability of assays performed across different reagent and array batches, methods of sample preservation, multiple personnel, and among different laboratories. This approach may be valuable when matched normal samples are unavailable or the paired normal specimens have been subjected to variations in methods of preservation.

  2. US EPA Region 4 Brownfields

    Science.gov (United States)

    To improve public health and the environment, the United States Environmental Protection Agency (USEPA) collects information about facilities, sites, or places subject to environmental regulation or of environmental interest. Through the Geospatial Data Download Service, the public is now able to download the EPA Geodata shapefile containing facility and site information from EPA's national program systems. The file is Internet accessible from the Envirofacts Web site (https://www3.epa.gov/enviro/). The data may be used with geospatial mapping applications. (Note: The shapefile omits facilities without latitude/longitude coordinates.) The EPA Geospatial Data contains the name, location (latitude/longitude), and EPA program information about specific facilities and sites. In addition, the file contains a Uniform Resource Locator (URL), which allows mapping applications to present an option to users to access additional EPA data resources on a specific facility or site. This dataset shows Brownfields listed in the 2012 Facility Registry System.

  3. Extending the use of references to the literature: Lessons from a content analysis of mixed method case exemplars

    DEFF Research Database (Denmark)

    Creamer, Elizabeth G.; Musaeus, Peter; Edwards, Cherie

    2018-01-01

    The role of references to the literature in a scholarly publication is conceived principally in terms of its foundational role in establishing the need for a study and framing its contribution. This methodological inquiry used content analysis to examine how authors of mixed methods exemplars dep...... of relevant literature may be particularly important in mixed methods research where a strong emergent strand often introduces heightens awareness that a phenomenon is more complex than initially conceived.......The role of references to the literature in a scholarly publication is conceived principally in terms of its foundational role in establishing the need for a study and framing its contribution. This methodological inquiry used content analysis to examine how authors of mixed methods exemplars...... deployed references to the literature in the discussion section of their manuscripts. These authors also deployed references to literature in the discussion section to support statements about the implications and significance of the research or to explain unexpected findings. Immersion in a broad range...

  4. Comparison of model reference and map based control method for vehicle stability enhancement

    NARCIS (Netherlands)

    Baek, S.; Son, M.; Song, J.; Boo, K.; Kim, H.

    2012-01-01

    A map based controller method to improve a vehicle lateral stability is proposed in this study and compared with the conventional method, a model referenced controller. A model referenced controller to determine compensated yaw moment uses the sliding mode method, but the proposed map based

  5. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 25 avril de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 30 mai, 29 août, 26 septembre, 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  6. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 28 février de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 28 mars, 25 avril, 30 mai, 29 août, 26 septembre, 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  7. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 28 mars de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 25 avril, 30 mai, 29 août, 26 septembre, 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  8. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 30 mai de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 29 août, 26 septembre, 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  9. Electrostatic Plasma Accelerator (EPA)

    Science.gov (United States)

    Brophy, John R.; Aston, Graeme

    1995-01-01

    The application of electric propulsion to communications satellites, however, has been limited to the use of hydrazine thrusters with electric heaters for thrust and specific impulse augmentation. These electrothermal thrusters operate at specific impulse levels of approximately 300 s with heater powers of about 500 W. Low power arcjets (1-3 kW) are currently being investigated as a way to increase specific impulse levels to approximately 500 s. Ion propulsion systems can easily produce specific impulses of 3000 s or greater, but have yet to be applied to communications satellites. The reasons most often given for not using ion propulsion systems are their high level of overall complexity, low thrust with long burn times, and the difficulty of integrating the propulsion system into existing commercial spacecraft busses. The Electrostatic Plasma Accelerator (EPA) is a thruster concept which promises specific impulse levels between low power arcjets and those of the ion engine while retaining the relative simplicity of the arcjet. The EPA thruster produces thrust through the electrostatic acceleration of a moderately dense plasma. No accelerating electrodes are used and the specific impulse is a direct function of the applied discharge voltage and the propellant atomic mass.

  10. A simple method for measuring glucose utilization of insulin-sensitive tissues by using the brain as a reference

    International Nuclear Information System (INIS)

    Namba, Hiroki; Nakagawa, Keiichi; Iyo, Masaomi; Fukushi, Kiyoshi; Irie, Toshiaki

    1994-01-01

    A simple method, without measurement of the plasma input function, to obtain semiquantitative values of glucose utilization in tissues other than the brain with radioactive deoxyglucose is reported. The brain, in which glucose utilization is essentially insensitive to plasma glucose and insulin concentrations, was used as an internal reference. The effects of graded doses of oral glucose loading (0.5, 1 and 2 mg/g body weight) on insulin-sensitive tissues (heart, muscle and fat tissue) were studied in the rat. By using the brain-reference method, dose-dependent increases in glucose utilization were clearly shown in all the insulin-sensitive tissues examined. The method seems to be of value for measurement of glucose utilization using radioactive deoxyglucose and positron emission tomography in the heart or other insulin-sensitive tissues, especially during glucose loading. (orig.)

  11. TLC densitometric method for screening of lycopsamine in comfrey root (Symphytum officinale L. extracts using retrorsine as a reference compound

    Directory of Open Access Journals (Sweden)

    Janeš Damjan

    2014-12-01

    Full Text Available Due to severe toxicity of pyrrolizidine alkaloids, their quantification in medicinal products is very important. The idea of this research was to use retrorsine as a surrogate reference compound instead of lycopsamine reference or lycopsamine isolated from comfrey. A method for the analysis of lycopsamine in extracts of comfrey roots was developed and validated, employing thin layer chromatography, derivatisation with Dann-Mattocks reagent followed by densitometric analysis. The new method showed linearity within 0.70 to 7.0 μg of lycopsamine per application of 10 μL of a solution. It has also been proven to be specific and precise (repeatability RSD 2-4 % within the plate. The method was successfully employed for quantification of lycopsamine in comfrey root and comfrey root medicinal products such as ointments.

  12. TLC densitometric method for screening of lycopsamine in comfrey root (Symphytum officinale L.) extracts using retrorsine as a reference compound.

    Science.gov (United States)

    Janeš, Damjan; Kreft, Samo

    2014-12-01

    Due to severe toxicity of pyrrolizidine alkaloids, their quantification in medicinal products is very important. The idea of this research was to use retrorsine as a surrogate reference compound instead of lycopsamine reference or lycopsamine isolated from comfrey. A method for the analysis of lycopsamine in extracts of comfrey roots was developed and validated, employing thin layer chromatography, derivatisation with Dann-Mattocks reagent followed by densitometric analysis. The new method showed linearity within 0.70 to 7.0 μg of lycopsamine per application of 10 μL of a solution. It has also been proven to be specific and precise (repeatability RSD 2-4 % within the plate). The method was successfully employed for quantification of lycopsamine in comfrey root and comfrey root medicinal products such as ointments.

  13. The utility of optical detection system (qPCR) and bioinformatics methods in reference gene expression analysis

    Science.gov (United States)

    Skarzyńska, Agnieszka; Pawełkowicz, Magdalena; PlÄ der, Wojciech; Przybecki, Zbigniew

    2016-09-01

    Real-time quantitative polymerase chain reaction is consider as the most reliable method for gene expression studies. However, the expression of target gene could be misinterpreted due to improper normalization. Therefore, the crucial step for analysing of qPCR data is selection of suitable reference genes, which should be validated experimentally. In order to choice the gene with stable expression in the designed experiment, we performed reference gene expression analysis. In this study genes described in the literature and novel genes predicted as control genes, based on the in silico analysis of transcriptome data were used. Analysis with geNorm and NormFinder algorithms allow to create the ranking of candidate genes and indicate the best reference for flower morphogenesis study. According to the results, genes CACS and CYCL were characterised the most stable expression, but the least suitable genes were TUA and EF.

  14. Automatic Enhancement of the Reference Set for Multi-Criteria Sorting in The Frame of Theseus Method

    Directory of Open Access Journals (Sweden)

    Fernandez Eduardo

    2014-05-01

    Full Text Available Some recent works have established the importance of handling abundant reference information in multi-criteria sorting problems. More valid information allows a better characterization of the agent’s assignment policy, which can lead to an improved decision support. However, sometimes information for enhancing the reference set may be not available, or may be too expensive. This paper explores an automatic mode of enhancing the reference set in the framework of the THESEUS multi-criteria sorting method. Some performance measures are defined in order to test results of the enhancement. Several theoretical arguments and practical experiments are provided here, supporting a basic advantage of the automatic enhancement: a reduction of the vagueness measure that improves the THESEUS accuracy, without additional efforts from the decision agent. The experiments suggest that the errors coming from inadequate automatic assignments can be kept at a manageable level.

  15. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. II. Selection of direct Kjeldahl analysis and its preliminary performance parameters.

    Science.gov (United States)

    Vinklárková, Bára; Chromý, Vratislav; Šprongl, Luděk; Bittová, Miroslava; Rikanová, Milena; Ohnútková, Ivana; Žaludová, Lenka

    2015-01-01

    To select a Kjeldahl procedure suitable for the determination of total protein in reference materials used in laboratory medicine, we reviewed in our previous article Kjeldahl methods adopted by clinical chemistry and found an indirect two-step analysis by total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. In this article, we compare both procedures on various reference materials. An indirect Kjeldahl method gave falsely lower results than a direct analysis. Preliminary performance parameters qualify the direct Kjeldahl analysis as a suitable primary reference procedure for the certification of total protein in reference laboratories.

  16. Standard Test Method for Determination of the Spectral Mismatch Parameter Between a Photovoltaic Device and a Photovoltaic Reference Cell

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers a procedure for the determination of a spectral mismatch parameter used in performance testing of photovoltaic devices. 1.2 The spectral mismatch parameter is a measure of the error, introduced in the testing of a photovoltaic device, caused by mismatch between the spectral responses of the photovoltaic device and the photovoltaic reference cell, as well as mismatch between the test light source and the reference spectral irradiance distribution to which the photovoltaic reference cell was calibrated. Examples of reference spectral irradiance distributions are Tables E490 or G173. 1.3 The spectral mismatch parameter can be used to correct photovoltaic performance data for spectral mismatch error. 1.4 This test method is intended for use with linear photovoltaic devices. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, a...

  17. Determination of reference data of REB diodes by using a numerical method for different applications

    International Nuclear Information System (INIS)

    Sinman, S.; Sinman, A.

    1982-01-01

    In this study, some reference data of a REB diode are presented functionally. These given characteristics are consisted of the computational results. Generally the numerical scheme depends upon the essential parameters of the charged transmission line and Child-Langmuir's diode model. By this system, further the correlation functions, some other definite functions such as the voltage of transmission line Vsub(L)(t), the diode voltage Vsub(d)(t), the diode current Isub(d)(t), the diode impedance Rsub(d)(t), the diode input power Wsub(d)(t), the dissipated energy Usub(d)(t), the efficiency phi, the beam density nsub(b)(t), the relativistic beam energy Usub(b)(t), and the intrinsic impedance Zsub(int)(t) have also been investigated. (author)

  18. 75 FR 45627 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Science.gov (United States)

    2010-08-03

    ... Research and Development on March 30, 2010. The analytical procedure of this method has been tested in... Protection Agency, Research Triangle Park, North Carolina 27711. Designation of this new equivalent method is... ENVIRONMENTAL PROTECTION AGENCY [FRL-9184-5] Office of Research and Development; Ambient Air...

  19. EPA's radon study results

    International Nuclear Information System (INIS)

    Dowd, R.M.

    1988-01-01

    Last winter, in cooperation with agencies in 10 states and two metropolitan area counties, EPA measured the indoor air radon concentrations of 14,000 houses, some chosen statistically at random and some by request of the homeowner. Passive measurement methodologies were used, such as exposing a charcoal canister to the air for a few days and allowing the air to migrate in to the charcoal naturally. To reduce dilution of radon by the outside air, the protocol required that the house be shut up; therefore, the study was conducted during winter. The measuring device was placed in the lowest livable area (usually the basement) of each house to maximize potential concentration. It should be noted that these procedures are generally considered to be screening tests because they result in a worst-case measurement rather than a best value. The results of these findings are presented

  20. Formulation of probabilistic models of protein structure in atomic detail using the reference ratio method

    DEFF Research Database (Denmark)

    Valentin, Jan B.; Andreetta, Christian; Boomsma, Wouter

    2014-01-01

    We propose a method to formulate probabilistic models of protein structure in atomic detail, for a given amino acid sequence, based on Bayesian principles, while retaining a close link to physics. We start from two previously developed probabilistic models of protein structure on a local length s....... The results indicate that the proposed method and the probabilistic models show considerable promise for probabilistic protein structure prediction and related applications. © 2013 Wiley Periodicals, Inc....

  1. Compilation of references, data sources and analysis methods for LMFBR primary piping system components

    International Nuclear Information System (INIS)

    Reich, M.; Esztergar, E.P.; Ellison, E.G.; Erdogan, F.; Gray, T.G.F.; Wells, C.W.

    1977-03-01

    A survey and review program for application of fracture mechanics methods in elevated temperature design and safety analysis has been initiated in December of 1976. This is the first of a series of reports, the aim of which is to provide a critical review of the theories of fracture and the application of fracture mechanics methods to life prediction, reliability and safety analysis of piping components in nuclear plants undergoing sub-creep and elevated temperature service conditions

  2. Urbanist workshops between theory and practice: The importance of spatial and programme reference levels in the planning method

    OpenAIRE

    Gregor Čok

    2013-01-01

    One of the key characteristics of urban-architectural workshops as a soft planning method is above all the fact that the authors are free of burden of formal facts and reference levels of the local environment, which do not influence the concept and the working process. Within this framework, the workshop presents an opportunity for the creator to focus primarily on the core of the problem, and work creatively towards a substantiated professional solution. In addition to the basic ref...

  3. Kernel reconstruction methods for Doppler broadening — Temperature interpolation by linear combination of reference cross sections at optimally chosen temperatures

    International Nuclear Information System (INIS)

    Ducru, Pablo; Josey, Colin; Dibert, Karia; Sobes, Vladimir; Forget, Benoit; Smith, Kord

    2017-01-01

    This paper establishes a new family of methods to perform temperature interpolation of nuclear interactions cross sections, reaction rates, or cross sections times the energy. One of these quantities at temperature T is approximated as a linear combination of quantities at reference temperatures (T_j). The problem is formalized in a cross section independent fashion by considering the kernels of the different operators that convert cross section related quantities from a temperature T_0 to a higher temperature T — namely the Doppler broadening operation. Doppler broadening interpolation of nuclear cross sections is thus here performed by reconstructing the kernel of the operation at a given temperature T by means of linear combination of kernels at reference temperatures (T_j). The choice of the L_2 metric yields optimal linear interpolation coefficients in the form of the solutions of a linear algebraic system inversion. The optimization of the choice of reference temperatures (T_j) is then undertaken so as to best reconstruct, in the L∞ sense, the kernels over a given temperature range [T_m_i_n,T_m_a_x]. The performance of these kernel reconstruction methods is then assessed in light of previous temperature interpolation methods by testing them upon isotope "2"3"8U. Temperature-optimized free Doppler kernel reconstruction significantly outperforms all previous interpolation-based methods, achieving 0.1% relative error on temperature interpolation of "2"3"8U total cross section over the temperature range [300 K,3000 K] with only 9 reference temperatures.

  4. SPM analysis of parametric (R)-[11C]PK11195 binding images: plasma input versus reference tissue parametric methods.

    Science.gov (United States)

    Schuitemaker, Alie; van Berckel, Bart N M; Kropholler, Marc A; Veltman, Dick J; Scheltens, Philip; Jonker, Cees; Lammertsma, Adriaan A; Boellaard, Ronald

    2007-05-01

    (R)-[11C]PK11195 has been used for quantifying cerebral microglial activation in vivo. In previous studies, both plasma input and reference tissue methods have been used, usually in combination with a region of interest (ROI) approach. Definition of ROIs, however, can be labourious and prone to interobserver variation. In addition, results are only obtained for predefined areas and (unexpected) signals in undefined areas may be missed. On the other hand, standard pharmacokinetic models are too sensitive to noise to calculate (R)-[11C]PK11195 binding on a voxel-by-voxel basis. Linearised versions of both plasma input and reference tissue models have been described, and these are more suitable for parametric imaging. The purpose of this study was to compare the performance of these plasma input and reference tissue parametric methods on the outcome of statistical parametric mapping (SPM) analysis of (R)-[11C]PK11195 binding. Dynamic (R)-[11C]PK11195 PET scans with arterial blood sampling were performed in 7 younger and 11 elderly healthy subjects. Parametric images of volume of distribution (Vd) and binding potential (BP) were generated using linearised versions of plasma input (Logan) and reference tissue (Reference Parametric Mapping) models. Images were compared at the group level using SPM with a two-sample t-test per voxel, both with and without proportional scaling. Parametric BP images without scaling provided the most sensitive framework for determining differences in (R)-[11C]PK11195 binding between younger and elderly subjects. Vd images could only demonstrate differences in (R)-[11C]PK11195 binding when analysed with proportional scaling due to intersubject variation in K1/k2 (blood-brain barrier transport and non-specific binding).

  5. Evaluating the construct of triage acuity against a set of reference vignettes developed via modified Delphi method.

    Science.gov (United States)

    Twomey, Michèle; Wallis, Lee A; Myers, Jonathan E

    2014-07-01

    To evaluate the construct of triage acuity as measured by the South African Triage Scale (SATS) against a set of reference vignettes. A modified Delphi method was used to develop a set of reference vignettes. Delphi participants completed a 2-round consensus-building process, and independently assigned triage acuity ratings to 100 written vignettes unaware of the ratings given by others. Triage acuity ratings were summarised for all vignettes, and only those that reached 80% consensus during round 2 were included in the reference set. Triage ratings for the reference vignettes given by two independent experts using the SATS were compared with the ratings given by the international Delphi panel. Measures of sensitivity, specificity, associated percentages for over-triage/under-triage were used to evaluate the construct of triage acuity (as measured by the SATS) by examining the association between the ratings by the two experts and the international panel. On completion of the Delphi process, 42 of the 100 vignettes reached 80% consensus on their acuity rating and made up the reference set. On average, over all acuity levels, sensitivity was 74% (CI 64% to 82%), specificity 92% (CI 87% to 94%), under-triage occurred 14% (CI 8% to 23%) and over-triage 12% (CI 8% to 23%) of the time. The results of this study provide an alternative to evaluating triage scales against the construct of acuity as measured with the SATS. This method of using 80% consensus vignettes may, however, systematically bias the validity estimate towards better performance. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Solubilization methods and reference 2-DE map of cow milk fat globules.

    Science.gov (United States)

    Bianchi, Laura; Puglia, Michele; Landi, Claudia; Matteoni, Silvia; Perini, Daniele; Armini, Alessandro; Verani, Margherita; Trombetta, Claudia; Soldani, Patrizia; Roncada, Paola; Greppi, Gianfranco; Pallini, Vitaliano; Bini, Luca

    2009-07-21

    Milk fat globules (MFGs) are secretory vesicles assembled and secreted by mammary epithelial cells during lactation. They consist of fat globules surrounded by a lipid bilayer membrane which is derived from the apical membrane of the lactating cells. MFGs contain, besides lipids, proteins from the apical plasma membrane and from the cytoplasmatic material. Their peculiar vesicle nature makes them a suitable and easily available source of biological material in monitoring the physiopathological state of the mammary gland. Unfortunately, the conspicuous lipidic component of MFGs consistently limits protein extraction and purification for MFG proteomic investigations. This work deals with the development of a suitable procedure for protein extraction from the cow MFGs in order to qualitatively and quantitatively improve 2-D electropherograms of the MFG. MFGs were purified from raw milk by centrifugation and then delipidated/precipitated. The resulting protein pellets were solubilised using four different 2-D SDS PAGE compatible lysis buffers. Applied methodological procedures for protein extraction and evaluation of the resulting 2-D protein-pattern are presented and discussed. Using these procedures a reference 2-D map of cow milk fat globules is also reported. The majority of the obtained identifications was represented by proteins involved in lipid synthesis or in fat globule secretion.

  7. EPA'S strategy to reduce risk of radon

    International Nuclear Information System (INIS)

    Page, S.

    1993-01-01

    The Indoor Radon Abatement Act of 1988 (IRAA) directed EPA to undertake a variety of activities to address the growing public concern over dangers posed by exposure to indoor radon. Among other requirements, the law directed the Agency to study radon levels, evaluate mitigation methods, establish proficiency programs, assist states with program development, develop training centers, and provide public information. EPA has developed and implemented programs to address each of the key provisions of this statute. This paper presents EPA's broad national strategy to reduce radon risks. It combines and reinforces EPA's basic foundation, including its guiding policies and cooperative partnerships, with an overall management approach and focus for the future. The paper starts with an overview that introduces the strategy's four key elements: underlying policies and scientific principles, a decentralized system of states and other partners for targeting the public, multiple strategies for achieving radon risk reduction, and a strong focus on five key program priorities. This paper then discusses each of these elements in more detail and describes how they interact to guide future efforts and directions of the Agency

  8. Evaluation and Recalibration of Empirical Constant for Estimation of Reference Crop Evapotranspiration against the Modified Penman Method

    Science.gov (United States)

    Sasireka, K.; Jagan Mohan Reddy, C.; Charan Reddy, C.; Ramakrishnan, K.

    2017-07-01

    The major demand in our country is irrigation demand. Looking to the low irrigation potential and small water resources, it is felt necessary to see that water must be used economically and efficiently. This may be achieved by using latest methods of determination of water requirements for crops and applying the proper water management practices. Evapotranspiration (ET) is a basic for calculation of water requirement for crops. The various popular empirical equations for reference crop evapotranspiration (ETr) belong to three categories namely, Temperature, Radiation based methods and Combined methods. The above methods are site specific; hence it is necessary to recalibrate the coefficients for applying them in India. In the present paper, the standard combined method namely FAO modified Penman method was used to recalibrate the constants in temperature based (TB) methods and it can also be used to determine the ETr for the selected station. Four TB evapotranspiration models namely Blaney-Criddle, Romanenko, Kharrufa, and, Thronthwaite methods are recalibrated and the constant in each method are redefined for the data from Lekkur station, Cuddalore district in India. The result shows that, large error existed when ETr has been calculated with original constants. Hence regression equations were developed to minimise these variations in magnitude. It was found that out of four methods the Blaney-Criddle method suits better for the selected region.

  9. Comparison of methods for certification of stannic, stibium and lead traces in reference materials for steel

    Directory of Open Access Journals (Sweden)

    I. V. Khodakovskaya

    2016-01-01

    Full Text Available Development and introduction of new metallurgical technologies, new additional chemical compound indexes controlled in metallurgical materials demand to develop the new, more advanced methods of analytical control. The particular attention should be paid to identify the traces of stannic, stinium and lead because of their influence on metal characteristics.

  10. Methods And Systems For Using Reference Images In Acoustic Image Processing

    Science.gov (United States)

    Moore, Thomas L.; Barter, Robert Henry

    2005-01-04

    A method and system of examining tissue are provided in which a field, including at least a portion of the tissue and one or more registration fiducials, is insonified. Scattered acoustic information, including both transmitted and reflected waves, is received from the field. A representation of the field, including both the tissue and the registration fiducials, is then derived from the received acoustic radiation.

  11. Meet EPA Scientist Jody Shoemaker, Ph.D.

    Science.gov (United States)

    EPA research chemist Jody Shoemaker, Ph.D., works to support Agency efforts to protect drinking water. She helps develop methods for analyzing organic chemicals on the Drinking Water Contaminant Candidate List (CCL).

  12. Meet EPA Chemist Mark Strynar, Ph.D.

    Science.gov (United States)

    Dr. Mark Strynar is a physical scientist in EPA's Office of Research and Development. His research interests include developing methods to measure and analyze the movement of PFCs and other xenobiotic compounds in biological and environmental media

  13. EPA's Information Architecture and Web Taxonomy

    Science.gov (United States)

    EPA's Information Architecture creates a topical organization of our website, instead of an ownership-based organization. The EPA Web Taxonomy allows audiences easy access to relevant information from EPA programs, by using a common vocabulary.

  14. Reference Proteome Extracts for Mass Spec Instrument Performance Validation and Method Development

    Science.gov (United States)

    Rosenblatt, Mike; Urh, Marjeta; Saveliev, Sergei

    2014-01-01

    Biological samples of high complexity are required to test protein mass spec sample preparation procedures and validate mass spec instrument performance. Total cell protein extracts provide the needed sample complexity. However, to be compatible with mass spec applications, such extracts should meet a number of design requirements: compatibility with LC/MS (free of detergents, etc.)high protein integrity (minimal level of protein degradation and non-biological PTMs)compatibility with common sample preparation methods such as proteolysis, PTM enrichment and mass-tag labelingLot-to-lot reproducibility Here we describe total protein extracts from yeast and human cells that meet the above criteria. Two extract formats have been developed: Intact protein extracts with primary use for sample preparation method development and optimizationPre-digested extracts (peptides) with primary use for instrument validation and performance monitoring

  15. A time-domain method to generate artificial time history from a given reference response spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Gang Sik [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Song, Oh Seop [Dept. of Mechanical Engineering, Chungnam National University, Daejeon (Korea, Republic of)

    2016-06-15

    Seismic qualification by test is widely used as a way to show the integrity and functionality of equipment that is related to the overall safety of nuclear power plants. Another means of seismic qualification is by direct integration analysis. Both approaches require a series of time histories as an input. However, in most cases, the possibility of using real earthquake data is limited. Thus, artificial time histories are widely used instead. In many cases, however, response spectra are given. Thus, most of the artificial time histories are generated from the given response spectra. Obtaining the response spectrum from a given time history is straightforward. However, the procedure for generating artificial time histories from a given response spectrum is difficult and complex to understand. Thus, this paper presents a simple time-domain method for generating a time history from a given response spectrum; the method was shown to satisfy conditions derived from nuclear regulatory guidance.

  16. A time-domain method to generate artificial time history from a given reference response spectrum

    International Nuclear Information System (INIS)

    Shin, Gang Sik; Song, Oh Seop

    2016-01-01

    Seismic qualification by test is widely used as a way to show the integrity and functionality of equipment that is related to the overall safety of nuclear power plants. Another means of seismic qualification is by direct integration analysis. Both approaches require a series of time histories as an input. However, in most cases, the possibility of using real earthquake data is limited. Thus, artificial time histories are widely used instead. In many cases, however, response spectra are given. Thus, most of the artificial time histories are generated from the given response spectra. Obtaining the response spectrum from a given time history is straightforward. However, the procedure for generating artificial time histories from a given response spectrum is difficult and complex to understand. Thus, this paper presents a simple time-domain method for generating a time history from a given response spectrum; the method was shown to satisfy conditions derived from nuclear regulatory guidance

  17. Characterization of a new candidate isotopic reference material for natural Pb using primary measurement method.

    Science.gov (United States)

    Nonose, Naoko; Suzuki, Toshihiro; Shin, Ki-Cheol; Miura, Tsutomu; Hioki, Akiharu

    2017-06-29

    A lead isotopic standard solution with natural abundance has been developed by applying a mixture of a solution of enriched 208 Pb and a solution of enriched 204 Pb ( 208 Pb- 204 Pb double spike solution) as bracketing method. The amount-of-substance ratio of 208 Pb: 204 Pb in this solution is accurately measured by applying EDTA titrimetry, which is one of the primary measurement methods, to each enriched Pb isotope solution. Also metal impurities affecting EDTA titration and minor lead isotopes contained in each enriched Pb isotope solution are quantified by ICP-SF-MS. The amount-of-substance ratio of 208 Pb: 204 Pb in the 208 Pb- 204 Pb double spike solution is 0.961959 ± 0.000056 (combined standard uncertainty; k = 1). Both the measurement of lead isotope ratios in a candidate isotopic standard solution and the correction of mass discrimination in MC-ICP-MS are carried out by coupling of a bracketing method with the 208 Pb- 204 Pb double spike solution and a thallium internal addition method, where thallium solution is added to the standard and the sample. The measured lead isotope ratios and their expanded uncertainties (k = 2) in the candidate isotopic standard solution are 18.0900 ± 0.0046 for 206 Pb: 204 Pb, 15.6278 ± 0.0036 for 207 Pb: 204 Pb, 38.0626 ± 0.0089 for 208 Pb: 204 Pb, 2.104406 ± 0.00013 for 208 Pb: 206 Pb, and 0.863888 ± 0.000036 for 207 Pb: 206 Pb. The expanded uncertainties are about one half of the stated uncertainty for NIST SRM 981, for 208 Pb: 204 Pb, 207 Pb: 204 Pb and 206 Pb: 204 Pb, or one eighth, for 208 Pb: 206 Pb and 207 Pb: 206 Pb, The combined uncertainty consists of the uncertainties due to lead isotope ratio measurements and the remaining time-drift effect of mass discrimination in MC-ICP-MS, which is not removed by the coupled correction method. In the measurement of 208 Pb: 204 Pb, 207 Pb: 204 Pb and 206 Pb: 204 Pb, the latter contribution is two or three times larger than the former. When the coupling of

  18. 40 CFR 98.7 - What standardized methods are incorporated by reference into this part?

    Science.gov (United States)

    2010-07-01

    ... Hydraulic Cement, IBR approved for §§ 98.84(a), 98.84(b), and 98.84(c). (3) ASTM D235-02 (Reapproved 2007... Method for Density, Relative Density (Specific Gravity), or API Gravity of Crude Petroleum and Liquid..., Compressibility Factor, and Relative Density of Gaseous Fuels, IBR approved for §§ 98.34(a) and 98.254(e). (21...

  19. A quantitative analysis of Tl-201 myocardial perfusion image with special reference to circumferential profile method

    International Nuclear Information System (INIS)

    Miyanaga, Hajime

    1982-01-01

    A quantitative analysis of thallium-201 myocardial perfusion image (MPI) was attempted by using circumferential profile method (CPM) and the first purpose of this study is to assess the clinical utility of this method for the detection of myocardial ischemia. In patients with coronary artery disease, CPM analysis to exercise T1-MPI showed high sensitivity (9/12, 75%) and specificity (9/9, 100%), whereas exercise ECG showed high sensitivity (9/12, 75%), but relatively low specificity (7/9, 78%). In patients with myocardial infarction, CPM also showed high sensitivity (34/38, 89%) for the detection of myocardial necrosis, compared with visual interpretation (31/38, 81%) and with ECG (31/38, 81%). Defect score was correlated well with the number of abnormal Q waves. In exercise study, CPM was also sensitive to the change of perfusion defect in T1-MPI produced by exercise. So the results indicate that CPM is a good method not only quantitatively but also objectively to analyze T1-MPI. Although ECG is the most commonly used diagnostic tool for ischemic heart disease, several exercise induced ischemic changes in ECG have been still on discussion as criteria. So the second purpose of this study is to evaluate these ischemic ECG changes by exercise T1-MPI analized quantitatively. ST depression (ischemic 1 mm and junctional 2 mm or more), ST elevation (1 mm or more), and coronary T wave reversion in exercise ECG were though to be ischemic changes. (J.P.N.)

  20. Quantitative analysis of Tl-201 myocardial perfusion image with special reference to circumferential profile method

    Energy Technology Data Exchange (ETDEWEB)

    Miyanaga, Hajime [Kyoto Prefectural Univ. of Medicine (Japan)

    1982-08-01

    A quantitative analysis of thallium-201 myocardial perfusion image (MPI) was attempted by using circumferential profile method (CPM) and the first purpose of this study is to assess the clinical utility of this method for the detection of myocardial ischemia. In patients with coronary artery disease, CPM analysis to exercise T1-MPI showed high sensitivity (9/12, 75%) and specificity (9/9, 100%), whereas exercise ECG showed high sensitivity (9/12, 75%), but relatively low specificity (7/9, 78%). In patients with myocardial infarction, CPM also showed high sensitivity (34/38, 89%) for the detection of myocardial necrosis, compared with visual interpretation (31/38, 81%) and with ECG (31/38, 81%). Defect score was correlated well with the number of abnormal Q waves. In exercise study, CPM was also sensitive to the change of perfusion defect in T1-MPI produced by exercise. So the results indicate that CPM is a good method not only quantitatively but also objectively to analyze T1-MPI. Although ECG is the most commonly used diagnostic tool for ischemic heart disease, several exercise induced ischemic changes in ECG have been still on discussion as criteria. So the second purpose of this study is to evaluate these ischemic ECG changes by exercise T1-MPI analized quantitatively. ST depression (ischemic 1 mm and junctional 2 mm or more), ST elevation (1 mm or more), and coronary T wave reversion in exercise ECG were though to be ischemic changes.

  1. Evaluation of the Reference Numerical Parameters of the Monthly Method in ISO 13790 Considering S/V Ratio

    Directory of Open Access Journals (Sweden)

    Hee-Jeong Kwak

    2015-01-01

    Full Text Available Many studies have investigated the accuracy of the numerical parameters in the application of the quasi steady-state calculation method. The aim of this study is to derive the reference numerical parameters of the ISO 13790 monthly method by reflecting the surface-to-volume (S/V ratio and the characteristics of the structures. The calculation process was established, and the parameters necessary to derive the reference numerical parameters were calculated based on the input data prepared for the established calculation processes. The reference numerical parameters were then derived through regression analyses of the calculated parameters and the time constant. The parameters obtained from an apartment building and the parameters of the international standard were both applied to the Passive House Planning Package (PHPP and EnergyPlus programs, and the results were analyzed in order to evaluate the validity of the results. The analysis revealed that the calculation results based on the parameters derived from this study yielded lower error rates than those based on the default parameters in ISO 13790. However, the differences were shown to be negligible in the case of high heat capacity.

  2. A review of the methods for monitoring roe deer European populations with particular reference to Italy

    Directory of Open Access Journals (Sweden)

    Alberto Meriggi

    2009-02-01

    Full Text Available Abstract Throughout the last century, deer populations have shown a remarkable increase both in North America and Europe. As a consequence, the estimate of roe deer density has become a matter of interest. We reviewed the available literature on the methods used for monitoring roe deer populations in Europe from 1950 to 2004, with the aim of detecting the trend of papers and distribution of census techniques by years, countries and habitat types. Particular attention was paid to the census and monitoring methods adopted in Italy and Tuscany, which is the region where the roe deer is more carefully managed. Published papers showed an increasing trend, as did the number of methods used and their complexity. France, Italy, UK and Spain were the countries with the richest literature and the largest variety of methods applied. Eleven census methods have been applied in woods - particularly line transects, pellet group counts, CMR and IKA - with only 6 in open country, mainly pellet group counts. In Europe vantage points are more commonly used for planning culling programs, whilst in Italy, and particularly in Tuscany, the drive census and spotlight counts are mainly used. Unfortunately, in Europe, harvesting programs are still too much based on hunter knowledge and traditions. However the countries where the management of roe deer hunting is of more recent tradition make an exception to this rule. In Italy and Tuscany the methods of monitoring roe deer populations should be improved towards less expensive and more accurate methods. Riassunto Revisione dei metodi di monitoraggio delle popolazioni di capriolo in Europa con particolare riferimento all'Italia Le popolazioni di Cervidi hanno avuto nell'ultimo secolo un notevole incremento sia in America settentrionale, sia in Europa. Di conseguenza la densità delle popolazioni di capriolo è diventata oggetto di interessi diversi e la sua stima

  3. A Rapid Identification Method for Calamine Using Near-Infrared Spectroscopy Based on Multi-Reference Correlation Coefficient Method and Back Propagation Artificial Neural Network.

    Science.gov (United States)

    Sun, Yangbo; Chen, Long; Huang, Bisheng; Chen, Keli

    2017-07-01

    As a mineral, the traditional Chinese medicine calamine has a similar shape to many other minerals. Investigations of commercially available calamine samples have shown that there are many fake and inferior calamine goods sold on the market. The conventional identification method for calamine is complicated, therefore as a result of the large scale of calamine samples, a rapid identification method is needed. To establish a qualitative model using near-infrared (NIR) spectroscopy for rapid identification of various calamine samples, large quantities of calamine samples including crude products, counterfeits and processed products were collected and correctly identified using the physicochemical and powder X-ray diffraction method. The NIR spectroscopy method was used to analyze these samples by combining the multi-reference correlation coefficient (MRCC) method and the error back propagation artificial neural network algorithm (BP-ANN), so as to realize the qualitative identification of calamine samples. The accuracy rate of the model based on NIR and MRCC methods was 85%; in addition, the model, which took comprehensive multiple factors into consideration, can be used to identify crude calamine products, its counterfeits and processed products. Furthermore, by in-putting the correlation coefficients of multiple references as the spectral feature data of samples into BP-ANN, a BP-ANN model of qualitative identification was established, of which the accuracy rate was increased to 95%. The MRCC method can be used as a NIR-based method in the process of BP-ANN modeling.

  4. Advances in digital technology and orthodontics: a reference to the Invisalign method.

    Science.gov (United States)

    Melkos, Aristides B

    2005-05-01

    Increased aesthetic demands during orthodontic treatment resulted in several treatment alternatives. However, the need to avoid conventional fixed orthodontic appliances led, with the use of computer-aided scanning, imaging, and manufacturing technology, to the development of new therapy concepts such as Invisalign. The Invisalign orthodontic technique involves a series of clear removable appliances and has been applied to correct a variety of malocclusions. The Invisalign method is an aesthetic orthodontic option for many patients, but it is suited mainly to adults or adolescents who have a fully erupted dentition and it has its indications and limitations. It handles simple to moderate non-extraction alignments better than mild to moderate extraction cases. The aligners are clear and therefore aesthetically ideal for the patient; they are comfortable to wear and, as they are removable, they provide simplicity of care and better oral hygiene. They also allow the evaluation of treatment options in detail before beginning treatment by using a virtual treatment model. It is also important to point out that this method has some disadvantages, which are associated with patient compliance, limited control over specific tooth movements, and additional documentation time. The Invisalign concept is an aesthetic alternative in orthodontic treatment, with advantages and disadvantages. It can be utilized to treat simple to moderate alignment cases, especially in adults, and serves as an additional part of the armamentarium of the orthodontist.

  5. Standardization of glycohemoglobin results and reference values in whole blood studied in 103 laboratories using 20 methods.

    Science.gov (United States)

    Weykamp, C W; Penders, T J; Miedema, K; Muskiet, F A; van der Slik, W

    1995-01-01

    We investigated the effect of calibration with lyophilized calibrators on whole-blood glycohemoglobin (glyHb) results. One hundred three laboratories, using 20 different methods, determined glyHb in two lyophilized calibrators and two whole-blood samples. For whole-blood samples with low (5%) and high (9%) glyHb percentages, respectively, calibration decreased overall interlaboratory variation (CV) from 16% to 9% and from 11% to 6% and decreased intermethod variation from 14% to 6% and from 12% to 5%. Forty-seven laboratories, using 14 different methods, determined mean glyHb percentages in self-selected groups of 10 nondiabetic volunteers each. With calibration their overall mean (2SD) was 5.0% (0.5%), very close to the 5.0% (0.3%) derived from the reference method used in the Diabetes Control and Complications Trial. In both experiments the Abbott IMx and Vision showed deviating results. We conclude that, irrespective of the analytical method used, calibration enables standardization of glyHb results, reference values, and interpretation criteria.

  6. Recent applications of nuclear analytical methods to the certification of elemental content in NIST standard reference materials

    International Nuclear Information System (INIS)

    Greenberg, R.R.; Zeisler, R.; Mackey, E.A.

    2006-01-01

    Well-characterized, certified reference materials (CRMs) play an essential role in assuring the quality of analytical measurements. NIST has been producing CRMs, currently called NIST Standard Reference Materials (SRMs), to validate analytical measurements for nearly one hundred years. The predominant mode of certifying inorganic constituents in complex-matrix SRMs is through the use of two critically evaluated, independent analytical techniques at NIST. These techniques should have no significant sources of error in common. The use of nuclear analytical methods in combination with one of the chemically based analytical method at NIST eliminates the possibility of any significant, common error source. The inherent characteristics of the various forms of nuclear analytical methods make them extremely valuable for SRM certification. Instrumental NAA is nondestructive, which eliminates the possibility of any dissolution problems, and often provides homogeneity information. Radiochemical NAA typically provides nearly blank-free determinations of some highly important, but difficult elements at very low levels. Prompt-gamma NAA complements INAA, and provides independent determinations of some key elements. In addition, all significant uncertainty components can be evaluated for these techniques, and we believe these methods can meet all the requirements of a primary method of measurement as defined by ISO and the CCQM. NIST has certified several SRMs using INAA and RNAA as primary methods. In addition, NIST has compared measurements by INAA and PGAA with other primary methods as part of the CCQM intercomparisons of national metrology institutes. Some significant SRMs recently certified for inorganic constituents with contributions from the nuclear analytical methods include: Toxic Substances in Urine (SRM 2670a), Lake Superior Fish Tissue (SRM 1946), Air Particulate on Filter Media (SRM 2783), Inorganics in Marine Sediment (SRM 2702), Sediment for Solid Sampling (Small

  7. Reliability of different mark-recapture methods for population size estimation tested against reference population sizes constructed from field data.

    Directory of Open Access Journals (Sweden)

    Annegret Grimm

    Full Text Available Reliable estimates of population size are fundamental in many ecological studies and biodiversity conservation. Selecting appropriate methods to estimate abundance is often very difficult, especially if data are scarce. Most studies concerning the reliability of different estimators used simulation data based on assumptions about capture variability that do not necessarily reflect conditions in natural populations. Here, we used data from an intensively studied closed population of the arboreal gecko Gehyra variegata to construct reference population sizes for assessing twelve different population size estimators in terms of bias, precision, accuracy, and their 95%-confidence intervals. Two of the reference populations reflect natural biological entities, whereas the other reference populations reflect artificial subsets of the population. Since individual heterogeneity was assumed, we tested modifications of the Lincoln-Petersen estimator, a set of models in programs MARK and CARE-2, and a truncated geometric distribution. Ranking of methods was similar across criteria. Models accounting for individual heterogeneity performed best in all assessment criteria. For populations from heterogeneous habitats without obvious covariates explaining individual heterogeneity, we recommend using the moment estimator or the interpolated jackknife estimator (both implemented in CAPTURE/MARK. If data for capture frequencies are substantial, we recommend the sample coverage or the estimating equation (both models implemented in CARE-2. Depending on the distribution of catchabilities, our proposed multiple Lincoln-Petersen and a truncated geometric distribution obtained comparably good results. The former usually resulted in a minimum population size and the latter can be recommended when there is a long tail of low capture probabilities. Models with covariates and mixture models performed poorly. Our approach identified suitable methods and extended options to

  8. EPA Metadata Style Guide Keywords and EPA Organization Names

    Science.gov (United States)

    The following keywords and EPA organization names listed below, along with EPA’s Metadata Style Guide, are intended to provide suggestions and guidance to assist with the standardization of metadata records.

  9. EPA Office Points, Tutuila AS, 2009, US EPA Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA office location in Tutila Island in American Samoa. American Samoa is an unincorporated and unorganized territory of the United States, and administered by...

  10. Comparison of two different segmentation methods on planar lung perfusion scan with reference to quantitative value on SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Min Seok; Kang, Yeon Koo; Ha, Seung Gyun [Dept. of Nuclear Medicine, Seoul National University Hospital, Seoul (Korea, Republic of); and others

    2017-06-15

    Until now, there was no single standardized regional segmentation method of planar lung perfusion scan. We compared planar scan based two segmentation methods, which are frequently used in the Society of Nuclear Medicine, with reference to the lung perfusion single photon emission computed tomography (SPECT)/computed tomography (CT) derived values in lung cancer patients. Fifty-five lung cancer patients (male:female, 37:18; age, 67.8 ± 10.7 years) were evaluated. The patients underwent planar scan and SPECT/CT after injection of technetium-99 m macroaggregated albumin (Tc-99 m-MAA). The % uptake and predicted postoperative percentage forced expiratory volume in 1 s (ppoFEV1%) derived from both posterior oblique (PO) and anterior posterior (AP) methods were compared with SPECT/CT derived parameters. Concordance analysis, paired comparison, reproducibility analysis and spearman correlation analysis were conducted. The % uptake derived from PO method showed higher concordance with SPECT/CT derived % uptake in every lobe compared to AP method. Both methods showed significantly different lobar distribution of % uptake compared to SPECT/CT. For the target region, ppoFEV1% measured from PO method showed higher concordance with SPECT/CT, but lower reproducibility compared to AP method. Preliminary data revealed that every method significantly correlated with actual postoperative FEV1%, with SPECT/CT showing the best correlation. The PO method derived values showed better concordance with SPECT/CT compared to the AP method. Both PO and AP methods showed significantly different lobar distribution compared to SPECT/CT. In clinical practice such difference according to different methods and lobes should be considered for more accurate postoperative lung function prediction.

  11. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2013-01-01

    Dear GAC-EPA members, This year, owing to works in the main Auditorium, we have to hold our General assembly in the auditorium of the Globe on 27 March 2013 and we really hope that you can be present. We wish to give you some preliminary practical recommendations: Do not forget your CERN access card, the guards may carry out checks. As far as possible, use public transport because there is very limited parking. If you come by car, park your vehicle on the car parks inside CERN because the outside car park cannot be used by visitors. Refreshments cannot be organized in the Globe; they will be held in cafeteria n°1, which will force us to move by using CERN entrances A or B or via building 33 (access cards required here too). We thank you for your attention and hope to see you soon. Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 2 avril de 13 h 30 à 16 h 00 Salle de réunion de l&rsquo...

  12. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2013-01-01

    En tant que Président du GAC-EPA, je porte à votre connaissance ce communiqué émanant de la Direction du CERN. Le 2 juin 2013, le CERN inaugure le projet Passeport Big Bang, un parcours touristique et scientifique formé de dix plates-formes d'exposition devant dix sites du CERN dans le Pays de Gex et le Canton de Genève. Les plateformes sont reliées par des itinéraires balisés et par un jeu de piste. C'est un projet est mené en collaboration avec les communes du Pays de Gex, Meyrin et Genève Tourisme dans un souci de renforcer notre dialogue avec nos voisins : http://passeport-big-bang.web.cern.ch/fr. A l’occasion de cette inauguration, nous organisons un événement populaire et festif : le matin, les familles pourront participer à des randonnées à vélo tandis que les sportifs pourront tester les 5...

  13. Spatial Interpolation of Reference Evapotranspiration in India: Comparison of IDW and Kriging Methods

    Science.gov (United States)

    Hodam, Sanayanbi; Sarkar, Sajal; Marak, Areor G. R.; Bandyopadhyay, A.; Bhadra, A.

    2017-12-01

    In the present study, to understand the spatial distribution characteristics of the ETo over India, spatial interpolation was performed on the means of 32 years (1971-2002) monthly data of 131 India Meteorological Department stations uniformly distributed over the country by two methods, namely, inverse distance weighted (IDW) interpolation and kriging. Kriging was found to be better while developing the monthly surfaces during cross-validation. However, in station-wise validation, IDW performed better than kriging in almost all the cases, hence is recommended for spatial interpolation of ETo and its governing meteorological parameters. This study also checked if direct kriging of FAO-56 Penman-Monteith (PM) (Allen et al. in Crop evapotranspiration—guidelines for computing crop water requirements, Irrigation and drainage paper 56, Food and Agriculture Organization of the United Nations (FAO), Rome, 1998) point ETo produced comparable results against ETo estimated with individually kriged weather parameters (indirect kriging). Indirect kriging performed marginally well compared to direct kriging. Point ETo values were extended to areal ETo values by IDW and FAO-56 PM mean ETo maps for India were developed to obtain sufficiently accurate ETo estimates at unknown locations.

  14. Perturbational treatment of spin-orbit coupling for generally applicable high-level multi-reference methods

    Energy Technology Data Exchange (ETDEWEB)

    Mai, Sebastian; Marquetand, Philipp; González, Leticia [Institute of Theoretical Chemistry, University of Vienna, Währinger Str. 17, 1090 Vienna (Austria); Müller, Thomas, E-mail: th.mueller@fz-juelich.de [Institute for Advanced Simulation, Jülich Supercomputing Centre, Forschungszentrum Jülich, 52425 Jülich (Germany); Plasser, Felix [Interdisciplinary Center for Scientific Computing, University of Heidelberg, Im Neuenheimer Feld 368, 69120 Heidelberg (Germany); Lischka, Hans [Institute of Theoretical Chemistry, University of Vienna, Währinger Str. 17, 1090 Vienna (Austria); Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061 (United States)

    2014-08-21

    An efficient perturbational treatment of spin-orbit coupling within the framework of high-level multi-reference techniques has been implemented in the most recent version of the COLUMBUS quantum chemistry package, extending the existing fully variational two-component (2c) multi-reference configuration interaction singles and doubles (MRCISD) method. The proposed scheme follows related implementations of quasi-degenerate perturbation theory (QDPT) model space techniques. Our model space is built either from uncontracted, large-scale scalar relativistic MRCISD wavefunctions or based on the scalar-relativistic solutions of the linear-response-theory-based multi-configurational averaged quadratic coupled cluster method (LRT-MRAQCC). The latter approach allows for a consistent, approximatively size-consistent and size-extensive treatment of spin-orbit coupling. The approach is described in detail and compared to a number of related techniques. The inherent accuracy of the QDPT approach is validated by comparing cuts of the potential energy surfaces of acrolein and its S, Se, and Te analoga with the corresponding data obtained from matching fully variational spin-orbit MRCISD calculations. The conceptual availability of approximate analytic gradients with respect to geometrical displacements is an attractive feature of the 2c-QDPT-MRCISD and 2c-QDPT-LRT-MRAQCC methods for structure optimization and ab inito molecular dynamics simulations.

  15. Perturbational treatment of spin-orbit coupling for generally applicable high-level multi-reference methods

    International Nuclear Information System (INIS)

    Mai, Sebastian; Marquetand, Philipp; González, Leticia; Müller, Thomas; Plasser, Felix; Lischka, Hans

    2014-01-01

    An efficient perturbational treatment of spin-orbit coupling within the framework of high-level multi-reference techniques has been implemented in the most recent version of the COLUMBUS quantum chemistry package, extending the existing fully variational two-component (2c) multi-reference configuration interaction singles and doubles (MRCISD) method. The proposed scheme follows related implementations of quasi-degenerate perturbation theory (QDPT) model space techniques. Our model space is built either from uncontracted, large-scale scalar relativistic MRCISD wavefunctions or based on the scalar-relativistic solutions of the linear-response-theory-based multi-configurational averaged quadratic coupled cluster method (LRT-MRAQCC). The latter approach allows for a consistent, approximatively size-consistent and size-extensive treatment of spin-orbit coupling. The approach is described in detail and compared to a number of related techniques. The inherent accuracy of the QDPT approach is validated by comparing cuts of the potential energy surfaces of acrolein and its S, Se, and Te analoga with the corresponding data obtained from matching fully variational spin-orbit MRCISD calculations. The conceptual availability of approximate analytic gradients with respect to geometrical displacements is an attractive feature of the 2c-QDPT-MRCISD and 2c-QDPT-LRT-MRAQCC methods for structure optimization and ab inito molecular dynamics simulations

  16. Using LMS Method in Smoothing Reference Centile Curves for Lipid Profile of Iranian Children and Adolescents: A CASPIAN Study

    Directory of Open Access Journals (Sweden)

    M Hoseini

    2012-05-01

    Full Text Available

    Background and Objectives: LMS is a general monitoring method for fitting smooth reference centile curves in medical sciences. They provide the distribution of a measurement as it changes according to some covariates like age or time. This method describes the distribution of changes by three parameters; Mean, Coefficient of variation and Cox-Box power (skewness. Applying maximum penalized likelihood and spline function, the three curves are estimated and fitted and optimum smoothness is expressed by three curves. This study was conducted to provide the percentiles of lipid profile of Iranian children and adolescents by LMS.

     

    Methods: Smoothed reference centile curves of four groups of lipids (triglycerides, total-LDL- and HDL-cholesterol were developed from the data of 4824 Iranian school students, aged 6-18 years, living in six cities (Tabriz, Rasht, Gorgan, Mashad, Yazd and Tehran-Firouzkouh in Iran. Demographic and laboratory data were taken from the national study of the surveillance and prevention of non-communicable diseases from childhood (CASPIAN Study. After data management, data of 4824 students were included in the statistical analysis, which was conducted by the modified LMS method proposed by Cole. The curves were developed with a degree of freedom of four to ten with some tools such as deviance, Q tests, and detrended Q-Q plot were used for monitoring goodness of fit models.

     

    Results: All tools confirmed the model, and the LMS method was used as an appropriate method in smoothing reference centile. This method revealed the distributing features of variables serving as an objective tool to determine their relative importance.

     

    Conclusion: This study showed that the triglycerides level is higher and

  17. Interpretation Problem of Czubek's Σa Measurement Method. Reference Experiment on H3BO3 Solutions

    International Nuclear Information System (INIS)

    Krynicka, E.; Gabanska, B.; Woznicka, U.; Dabrowska, J.; Burda, J.

    2001-12-01

    Czubek's method of measurement of the thermal neutron absorption cross section may be influenced by the energy spectrum of the thermal neutron flux (deviated from the Maxwellian distribution) which exist in the two-region geometric system. A correction function has been experimentally obtained to eliminate this disturbance. A series of reference measurements has been done on the H 3 BO 3 solution and Plexiglas outer moderator. The obtained function allows to interpret correctly measurements of the thermal neutron absorption rate in the range from 10 000 to 45 000 s -1 for hydrogenous samples. (author)

  18. Reference scenarios for deforestation and forest degradation in support of REDD: a review of data and methods

    International Nuclear Information System (INIS)

    Olander, Lydia P; Murray, Brian C; Gibbs, Holly K; Steininger, Marc; Swenson, Jennifer J

    2008-01-01

    Global climate policy initiatives are now being proposed to compensate tropical forest nations for reducing carbon emissions from deforestation and forest degradation (REDD). These proposals have the potential to include developing countries more actively in international greenhouse gas mitigation and to address a substantial share of the world's emissions which come from tropical deforestation. For such a policy to be viable it must have a credible benchmark against which emissions reduction can be calculated. This benchmark, sometimes termed a baseline or reference emissions scenario, can be based directly on historical emissions or can use historical emissions as input for business as usual projections. Here, we review existing data and methods that could be used to measure historical deforestation and forest degradation reference scenarios including FAO (Food and Agricultural Organization of the United Nations) national statistics and various remote sensing sources. The freely available and corrected global Landsat imagery for 1990, 2000 and soon to come for 2005 may be the best primary data source for most developing countries with other coarser resolution high frequency or radar data as a valuable complement for addressing problems with cloud cover and for distinguishing larger scale degradation. While sampling of imagery has been effectively useful for pan-tropical and continental estimates of deforestation, wall-to-wall (or full coverage) allows more detailed assessments for measuring national-level reference emissions. It is possible to measure historical deforestation with sufficient certainty for determining reference emissions, but there must be continued calls at the international level for making high-resolution imagery available, and for financial and technical assistance to help countries determine credible reference scenarios. The data available for past years may not be sufficient for assessing all forms of forest degradation, but new data sources

  19. Comparison of the respiratory tract models of ICRP and US EPA

    International Nuclear Information System (INIS)

    Wu Tao

    2000-01-01

    An index for the integral characterization of risk is necessary for improving risk management, comparing the effects of various practices on the environment and keeping risk as low as reasonably achievable while allowing economic development. Public health risk has been used as an index to compare and combine the risks from the presence of a variety of contaminants. In 1994, International Commission on Radiological Protection published the Publication 66 'Human Respiratory Tract Model for Radiological Protection'. Meanwhile US EPA published 'Methods for Derivation of Inhalation Reference Concentrations and Application of Inhalation Dosimetry'. Basically the concept of Reference Concentration (RfC) is similar to that of DAC used in radiation protection. Both of them are derived from the deposited amount of interested contaminants in the respiratory tract. In an attempt to assess the public health risk by combining the ICRP model and the deposited amount corresponding to values of RfC, the main application, especially the fractional deposition, of the respiratory tract model of US EPA is compared with the new respiratory tract model of ICRP. For normal nose breather, when the AMADs of monodisperse aerosol are 0.5 η m, 1 η m, 2 η m, 3 η m, 5 η m, 7 η m and 10 η m, minute volume is 1.2m 3 /h (20L/mim), the corresponding total fractional depositions calculated by the model of the US EPA are 0.33, 0.50, 0.72, 0.85, 0.95, 0.97 and 0.93. With the same condition, the total fractional deposition calculated by the ICRP model is 0.35, 0.51, 0.70, 0.78, 0.82, 0.81 and 0.77. For polydisperse aerosol with default values of ICRP for occupational and environmental exposures, the fractional depositions calculated by US EPA model are 0.82 and 0.50 while that by ICRP are 0.82 and 0.47. In conclusion, (1) The ICRP model is more accurate than the US EPA model and has a wider application. (2) For monodisperse aerosol, when the AMAD of aerosol is less than 3 η m there is no

  20. EPA Collaboration with South Korea

    Science.gov (United States)

    EPA, the Ministry of Environment of Korea, and partner agencies in both countries cooperate to strengthen environmental governance, improve air and water quality, and reduce exposure to toxic chemicals.

  1. EPA scientific integrity policy draft

    Science.gov (United States)

    Showstack, Randy

    2011-08-01

    The U.S. Environmental Protection Agency (EPA) issued its draft scientific integrity policy on 5 August. The draft policy addresses scientific ethical standards, communications with the public, the use of advisory committees and peer review, and professional development. The draft policy was developed by an ad hoc group of EPA senior staff and scientists in response to a December 2010 memorandum on scientific integrity from the White House Office of Science and Technology Policy. The agency is accepting public comments on the draft through 6 September; comments should be sent to osa.staff@epa.gov. For more information, see http://www.epa.gov/stpc/pdfs/draft-scientific-integrity-policy-aug2011.pdf.

  2. Utility of Penman-Monteith, Priestley-Taylor, reference evapotranspiration, and pan evaporation methods to estimate pasture evapotranspiration

    Science.gov (United States)

    Sumner, D.M.; Jacobs, J.M.

    2005-01-01

    Actual evapotranspiration (ETa) was measured at 30-min resolution over a 19-month period (September 28, 2000-April 23, 2002) from a nonirrigated pasture site in Florida, USA, using eddy correlation methods. The relative magnitude of measured ETa (about 66% of long-term annual precipitation at the study site) indicates the importance of accurate ET a estimates for water resources planning. The time and cost associated with direct measurements of ETa and the rarity of historical measurements of ETa make the use of methods relying on more easily obtainable data desirable. Several such methods (Penman-Monteith (PM), modified Priestley-Taylor (PT), reference evapotranspiration (ET 0), and pan evaporation (Ep)) were related to measured ETa using regression methods to estimate PM bulk surface conductance, PT ??, ET0 vegetation coefficient, and Ep pan coefficient. The PT method, where the PT ?? is a function of green-leaf area index (LAI) and solar radiation, provided the best relation with ET a (standard error (SE) for daily ETa of 0.11 mm). The PM method, in which the bulk surface conductance was a function of net radiation and vapor-pressure deficit, was slightly less effective (SE=0.15 mm) than the PT method. Vegetation coefficients for the ET0 method (SE=0.29 mm) were found to be a simple function of LAI. Pan coefficients for the Ep method (SE=0.40 mm) were found to be a function of LAI and Ep. Historical or future meteorological, LAI, and pan evaporation data from the study site could be used, along with the relations developed within this study, to provide estimates of ETa in the absence of direct measurements of ETa. Additionally, relations among PM, PT, and ET0 methods and ETa can provide estimates of ETa in other, environmentally similar, pasture settings for which meteorological and LAI data can be obtained or estimated. ?? 2004 Elsevier B.V. All rights reserved.

  3. Hg0 and HgCl2 Reference Gas Standards: ?NIST Traceability ...

    Science.gov (United States)

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the true concentrations of Hg0 and HgCl2 reference gases produced from high quality, NIST-traceable, commercial Hg0 and HgCl2 generators. This presentation will also discuss the availability of HCl and Hg0 compressed reference gas standards as a result of EPA's recently approved Alternative Methods 114 and 118. Gaseous elemental mercury (Hg0) and oxidized mercury (HgCl2) reference standards are integral to the use of mercury continuous emissions monitoring systems (Hg CEMS) for regulatory compliance emissions monitoring. However, a quantitative disparity of approximately 7-10% has been observed between commercial Hg0 and HgCl2 reference gases which currently limits the use of (HgCl2) reference gas standards. Resolving this disparity would enable the expanded use of (HgCl2) reference gas standards for regulatory compliance purposes.

  4. Determining experimentally the parameters of the unsteady thermal behaviour of homogeneously layered walls by the reference plates method

    International Nuclear Information System (INIS)

    Beron, Rodolphe

    1988-01-01

    In this work, we introduce an experimental determination method of parameters which are characteristics of the transfer functions of walls in buildings by the use of an easy equipment which use needs no significant constraint. This method called 'reference plates method' is based on the working out of the thermo-grams which result from any thermal perturbation. The first part of our work deals with the theoretical development of the methods of working out the measures used for both single-Iayered and multi-layered walls. The second part discusses the applying of the method on single-Iayered sample. The values of thermophysical characteristics of the wall is based on the working out of the heat equation written in terms an integral transformation which we take as Laplace's transformation. The case of multi-Iayered wall which we discuss in the third part, lead to the determination of 'z transforms coefficients' of the transfer functions of the studied wall. In addition to the theoretical study, we analyse the results of prospective experiments in the fourth part of our work and show the usefulness of such a measurement method. The last part is devoted to the presentation of the application of our work to the determination of thermal parameters of more general wall's configurations. (author) [fr

  5. An internal reference model-based PRF temperature mapping method with Cramer-Rao lower bound noise performance analysis.

    Science.gov (United States)

    Li, Cheng; Pan, Xinyi; Ying, Kui; Zhang, Qiang; An, Jing; Weng, Dehe; Qin, Wen; Li, Kuncheng

    2009-11-01

    The conventional phase difference method for MR thermometry suffers from disturbances caused by the presence of lipid protons, motion-induced error, and field drift. A signal model is presented with multi-echo gradient echo (GRE) sequence using a fat signal as an internal reference to overcome these problems. The internal reference signal model is fit to the water and fat signals by the extended Prony algorithm and the Levenberg-Marquardt algorithm to estimate the chemical shifts between water and fat which contain temperature information. A noise analysis of the signal model was conducted using the Cramer-Rao lower bound to evaluate the noise performance of various algorithms, the effects of imaging parameters, and the influence of the water:fat signal ratio in a sample on the temperature estimate. Comparison of the calculated temperature map and thermocouple temperature measurements shows that the maximum temperature estimation error is 0.614 degrees C, with a standard deviation of 0.06 degrees C, confirming the feasibility of this model-based temperature mapping method. The influence of sample water:fat signal ratio on the accuracy of the temperature estimate is evaluated in a water-fat mixed phantom experiment with an optimal ratio of approximately 0.66:1. (c) 2009 Wiley-Liss, Inc.

  6. The upper reference limit for thyroid peroxidase autoantibodies is method-dependent: A collaborative study with biomedical industries.

    Science.gov (United States)

    Tozzoli, Renato; D'Aurizio, Federica; Ferrari, Anna; Castello, Roberto; Metus, Paolo; Caruso, Beatrice; Perosa, Anna Rosa; Sirianni, Francesca; Stenner, Elisabetta; Steffan, Agostino; Villalta, Danilo

    2016-01-15

    The determination of the upper reference limit (URL) for thyroid peroxidase autoantibodies (TPOAbs) is a contentious issue, because of the difficulty in defining the reference population. The aim of this study was to establish the URL (eURL) for TPOAbs, according to the National Academy of Clinical Biochemistry (NACB) guidelines and to compare them with those obtained in a female counterpart, by the use of six commercial automated platforms. 120 healthy males and 120 healthy females with NACB-required characteristics (Lumipulse G1200, Fujirebio. Within each method, TPOAbs values had a high degree of dispersion and the eURLs were lower than those stated by the manufacturer. A statistically significant difference (p0.05). Despite the analytical harmonization, the wide dispersion of the results and the differences of the eURLs between methods suggest the need of further studies focusing on TPO antigen preparations as the possible source of variability between different assays. In addition, the lack of clinical significant difference between males and females, in terms of TPOAb eURLs, confirms the suitability of the NACB recommendations. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Development of liquid chromatographic methods for the determination of phytosterols in Standard Reference Materials containing saw palmetto.

    Science.gov (United States)

    Bedner, Mary; Schantz, Michele M; Sander, Lane C; Sharpless, Katherine E

    2008-05-23

    Liquid chromatographic (LC) methods using atmospheric pressure chemical ionization/mass spectrometric (APCI-MS) detection were developed for the separation and analysis of the phytosterols campesterol, cycloartenol, lupenone, lupeol, beta-sitosterol, and stigmasterol. Brassicasterol and cholesterol were also included for investigation as internal standards. The methods were used to identify and quantify the phytosterols in each of two Serenoa repens (saw palmetto) Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST). Values obtained by LC-MS were compared to those obtained using the more traditional approach of gas chromatography with flame ionization detection. This is the first reported use of LC-MS to determine phytosterols in saw palmetto dietary supplement materials.

  8. EPA for Businesses and Non-Profits

    Science.gov (United States)

    Information and links to EPA web pages that are meant to help businesses and non-profits adhere to EPA regulations and otherwise protect the environment, take advantage of opportunities to collaborate with the EPA, and find training EPA training programs.

  9. EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. II. Total Culturable Virus Assay

    Science.gov (United States)

    A standardized method is required when national studies on virus occurrence in environmental and drinking waters utilize multiple analytical laboratories. The U.S Environmental Protection Agency’s (USEPA) Method 1615 was developed with the goal of providing such a standard ...

  10. Report: Improvements Needed by EPA to Reduce Risk in Employee Hiring Process

    Science.gov (United States)

    Report #15-P-0253, August 3, 2015. Without verification of prior employment or references, the potential exists that the EPA will not hire the best possible staff, or will hire an employee based on false statements.

  11. EPA Method 8321B (SW-846): Solvent-Extractable Nonvolatile Compounds by High Performance Liquid Chromatography-Thermospray-Mass Spectrometry (HPLC-TS-MS) or Ultraviolet (UV) Detection

    Science.gov (United States)

    Method 8321B describes procedures for preparation and analysis of solid, aqueous liquid, drinking water and wipe samples using high performance liquid chromatography and mass spectrometry for extractable non-volatile compounds.

  12. Methods for definition of reference conditions for a repository site taking long-term environmental change into account

    Energy Technology Data Exchange (ETDEWEB)

    Ikonen, A.T.K. [Environmental Research and Assessment EnviroCase, Ltd. (Finland)

    2014-07-01

    In a few countries, programmes for disposal of spent nuclear fuel have proceeded into a site-specific phase, and the number of low- and intermediate-level nuclear waste repositories requiring updated state-of-the-art long-term safety assessments is considerable. In this contribution, the approach employed in the Finnish spent fuel disposal programme is analysed and used as an example for a more general methodology for defining reference surface conditions for a site, e.g. to guide selection of representative input data to safety assessments, using spatio-temporal analogues so that long-term environmental changes are taken into account. The contribution incorporates also elements from discussions in the IAEA EMRAS II and MODARIA working groups on addressing the environmental change in the assessments. The legacy of the earlier BIOMASS project is also recognised. Broadly, the methods to be presented include identification of similarity factors (e.g. geological, biological and climate regimes) upon which a reference area can be delineated. Within the reference area, characteristic lines of development and biotopes are identified and described, and these are then used to guide further research and application of literature data to iteratively accumulate adequate understanding of the site conditions and relevant processes at the present and in the future (by projecting further the past and present development lines and biotopes). In this iterative approach, also the intensity of research efforts can be adjusted with the stage of the repository programme, as will be discussed in the complete contribution. Document available in abstract form only. (authors)

  13. Comparison of platelet counts by sysmex XE 2100 and LH-750 with the international flow reference method in thrombocytopenic patients

    Directory of Open Access Journals (Sweden)

    Tina Dadu

    2013-01-01

    Full Text Available Background: There are several methods for counting platelets, of which the international flow reference method (IRM is considered to be the gold standard. We compared the platelet count given by this method to the count given by automated analyzers using other methods, such as optical fluorescence and impedance. Aims: The aim of this study is to compare the platelet counts obtained by Sysmex XE 2100 by Impedance (Sysmex-I, optical florescence (Sysmex-O and reported (Sysmex-R based on the switching algorithm and LH-750 by Impedance (LH-750 with the IRM in thrombocytopenic blood samples. To calculate the sensitivity, specificity, positive predictive value (PPV and negative predictive value (NPV of various technologies at the clinically relevant transfusion thresholds of 10 × 10 9 /l and 20 × 10 9 /l. Materials and Methods: A total of 118 blood samples with platelet count of <50 × 10 9 /l were selected for the study. Platelet counts of all samples were analyzed by all methods using the Sysmex analyzer, LH-750 and IRM in parallel within 6 h of collection. Statistical Analysis Used: Pearson correlation, bland Altman analysis, sensitivity and specificity, PPV and NPV. Results and Conclusions: Sysmex-R had the least Bias and 95% limits of agreement (95%LA range and thus correlated best with IRM values. LH-750 had a higher Bias compared to Sysmex-O and Sysmex-R, but a strikingly similar 95% LA ensures similar results in all three methods. In fact, in the oncology subset, it had the narrowest 95% LA, which made it the best performer in this subgroup. Of the three Sysmex results, Sysmex-I had the highest bias, widest 95% LA and highest potential risk of over transfusion. Hence, Sysmex-R and LH-750 were found to be reliable tools for estimation of platelet count in thrombocytopenic patients.

  14. A novel method of calibrating a MEMS inertial reference unit on a turntable under limited working conditions

    Science.gov (United States)

    Lu, Jiazhen; Liang, Shufang; Yang, Yanqiang

    2017-10-01

    Micro-electro-mechanical systems (MEMS) inertial measurement devices tend to be widely used in inertial navigation systems and have quickly emerged on the market due to their characteristics of low cost, high reliability and small size. Calibration is the most effective way to remove the deterministic error of an inertial reference unit (IRU), which in this paper consists of three orthogonally mounted MEMS gyros. However, common testing methods in the lab cannot predict the corresponding errors precisely when the turntable’s working condition is restricted. In this paper, the turntable can only provide a relatively small rotation angle. Moreover, the errors must be compensated exactly because of the great effect caused by the high angular velocity of the craft. To deal with this question, a new method is proposed to evaluate the MEMS IRU’s performance. In the calibration procedure, a one-axis table that can rotate a limited angle in the form of a sine function is utilized to provide the MEMS IRU’s angular velocity. A new algorithm based on Fourier series is designed to calculate the misalignment and scale factor errors. The proposed method is tested in a set of experiments, and the calibration results are compared to a traditional calibration method performed under normal working conditions to verify their correctness. In addition, a verification test in the given rotation speed is implemented for further demonstration.

  15. Transforming an EPA QA/R-2 quality management plan into an ISO 9002 quality management system.

    Science.gov (United States)

    Kell, R A; Hedin, C M; Kassakhian, G H; Reynolds, E S

    2001-01-01

    The Environmental Protection Agency's (EPA) Office of Emergency and Remedial Response (OERR) requires environmental data of known quality to support Superfund hazardous waste site projects. The Quality Assurance Technical Support (QATS) Program is operated by Shaw Environmental and Infrastructure, Inc. to provide EPA's Analytical Operations Center (AOC) with performance evaluation samples, reference materials, on-site laboratory auditing capabilities, data audits (including electronic media data audits), methods development, and other support services. The new QATS contract awarded in November 2000 required that the QATS Program become ISO 9000 certified. In a first for an EPA contractor, the QATS staff and management successfully transformed EPA's QA/R-2 type Quality Management Plan into a Quality Management System (QMS) that complies with the requirements of the internationally recognized ISO 9002 standard and achieved certification in the United States, Canada, and throughout Europe. The presentation describes how quality system elements of ISO 9002 were implemented on an already existing quality system. The psychological and organizational challenges of the culture change in QATS' day-to-day operations will be discussed for the benefit of other ISO 9000 aspirants.

  16. Determinations of silicon and phosphorus in Pepperbush standard reference material by neutron activation and x-ray fluorescence methods

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Nishio, Hirofumi; Hayashi, Takeshi; Kusakabe, Toshio; Iwata, Shiro.

    1987-01-01

    Silicon and phosphorus contents in Pepperbush standard reference material were determined by neutron activation and X-ray fluorescence methods. In neutron activation analysis, β-ray spectra of 32 P produced by 31 P(n,γ) 32 P reaction on Pepperbush and standard samples were measured by a low background β-ray spectrometer. In X-ray fluorescence analysis, the standard samples were prepared by mixing the Pepperbush powder with silicon dioxide and diammonium hydrogenphosphate. Characteristic X-rays from the samples were analyzed by a wavelength dispersive X-ray fluorescence spectrometer. From the β and X-ray intensities, silicon and phosphorus contents in Pepperbush were determined to be 1840 ± 80 and 1200 ± 50 μg g -1 , respectively. (author)

  17. Validation of a liquid chromatographic method for determination of related substances in a candidate certified reference material of captopril

    Directory of Open Access Journals (Sweden)

    Raquel Nogueira

    2011-06-01

    Full Text Available This paper describes the validation of a reversed-phase high performance liquid chromatography method (RP-HPLC with diode array detection (DAD for determination of related substances (impurities from organic synthesis and degradation products of captopril according to the Brazilian Pharmacopeia IV. The aim of this study was to guarantee the method accuracy for quantification of related substances, an essential requisite to determine, using the mass balance approach, the captopril content in the first Brazilian certified reference material (CRM of an active pharmaceutical ingredient (API, developed by Inmetro. The captopril instability in solution is discussed and the captopril content determined by mass balance is compared to the results from titration and differential scanning calorimetry (DSC.Este artigo descreve a validação de método de cromatografia líquida de alta eficiência em fase reversa (CLAE-RP com detector de fotodiodos (DAD para determinação de substâncias relacionadas (impurezas orgânicas de síntese e produtos de degradação de captopril segundo Farmacopéia Brasileira IV ed. Este estudo teve como objetivo garantir que o método é capaz de quantificar com exatidão o teor de substâncias relacionadas, um requisito essencial para que o teor de captopril seja determinado por balanço de massa no primeiro material de referência certificado (MRC de fármacos brasileiro, o qual foi desenvolvido pelo Inmetro. A instabilidade do captopril em solução é discutida em detalhes e o teor de captopril determinado por balanço de massa é comparado com aqueles obtidos por titulação e por calorimetria exploratória diferencial (DSC.

  18. Medical reference dosimetry using EPR measurements of alanine: Development of an improved method for clinical dose levels

    International Nuclear Information System (INIS)

    Helt-Hansen, Jakob; Andersen, Claus Erik; Rosendal, Flemming; Kofoed, Inger Matilde

    2009-01-01

    Electron spin resonance (EPR) is used to determine the absorbed dose of alanine dosimeters exposed to clinical photon beams in a solid-water phantom. Alanine is potentially suitable for medical reference dosimetry, because of its near water equivalence over a wide energy spectrum, low signal fading, non-destructive measurement and small dosimeter size. Material and Methods. A Bruker EMX-micro EPR spectrometer with a rectangular cavity and a measurement time of two minutes per dosimeter was used for reading of irradiated alanine dosimeters. Under these conditions a new algorithm based on scaling of known spectra was developed to extract the alanine signal. Results. The dose accuracy, including calibration uncertainty, is less than 2% (k=1) above 4 Gy (n=4). The measurement uncertainty is fairly constant in absolute terms (∼30 mGy) and the relative uncertainty therefore rises for dose measurements below 4 Gy. Typical reproducibility is <1% (k=1) above 10 Gy and <2% between 4 and 10 Gy. Below 4 Gy the uncertainty is higher. A depth dose curve measurement was performed in a solid-water phantom irradiated to a dose of 20 Gy at the maximum dose point (dmax) in 6 and 18 MV photon beams. The typical difference between the dose measured with alanine in solid water and the dose measured with an ion chamber in a water tank was about 1%. A difference of 2% between 6 and 18 MV was found, possibly due to non-water equivalence of the applied phantom. Discussion. Compared to previously published methods the proposed algorithm can be applied without normalisation of phase shifts caused by changes in the g-value of the cavity. The study shows that alanine dosimetry is a suitable candidate for medical reference dosimetry especially for quality control applications

  19. REFERENCE MATERIALS SYSTEM OF SCIENTIFIC METHODICAL CENTRE OF STATE SERVICE OF REFERENCE MATERIALS FOR COMPOSITION AND PROPERTIES OF SUBSTANCES AND MATERIALS URAL RESEARCH INSTITUTE FOR METROLOGY

    Directory of Open Access Journals (Sweden)

    E. V. Osinseva

    2015-01-01

    Full Text Available Since 1960s UNIIM performs research in the field of needs in reference materials of composition and properties of substances and materials (RM as well as develops it. During the research UNIIM has developed 757 types of RMs for metrological measurement assurance of factors of composition and properties of substance and materials for test laboratories of chemical, pharmaceutical, fuel, food industry, agriculture, metallurgy and ecological monitoring laboratories. List ofRMs enlarges thanks to development of UNIIM standards and transmission measurement facility from State standards of units. Taking into account the actual requirements in the field of measurements, the UNIIM's key destination is to assure the accuracy and the metrological traceability of measurements. The present-day system of RMs to be developed in UNIIM includes RMs of composition of inorganic and organic compounds and their solutions, fuels, stable isotopic materials, water, grounds, food products, biomaterials, nanomaterials, metals, alloys and other materials offerrous and non-ferrous industry, RMs of properties (thermodynamic, magnetic, physical-chemical, technical of substances and materials. The present article considers history of RMs list development which were created by UNIIM and the strategy of this direction.

  20. Task-oriented comparison of power spectral density estimation methods for quantifying acoustic attenuation in diagnostic ultrasound using a reference phantom method.

    Science.gov (United States)

    Rosado-Mendez, Ivan M; Nam, Kibo; Hall, Timothy J; Zagzebski, James A

    2013-07-01

    Reported here is a phantom-based comparison of methods for determining the power spectral density (PSD) of ultrasound backscattered signals. Those power spectral density values are then used to estimate parameters describing α(f), the frequency dependence of the acoustic attenuation coefficient. Phantoms were scanned with a clinical system equipped with a research interface to obtain radiofrequency echo data. Attenuation, modeled as a power law α(f)= α0 f (β), was estimated using a reference phantom method. The power spectral density was estimated using the short-time Fourier transform (STFT), Welch's periodogram, and Thomson's multitaper technique, and performance was analyzed when limiting the size of the parameter-estimation region. Errors were quantified by the bias and standard deviation of the α0 and β estimates, and by the overall power-law fit error (FE). For parameter estimation regions larger than ~34 pulse lengths (~1 cm for this experiment), an overall power-law FE of 4% was achieved with all spectral estimation methods. With smaller parameter estimation regions as in parametric image formation, the bias and standard deviation of the α0 and β estimates depended on the size of the parameter estimation region. Here, the multitaper method reduced the standard deviation of the α0 and β estimates compared with those using the other techniques. The results provide guidance for choosing methods for estimating the power spectral density in quantitative ultrasound methods.

  1. Precision of glucose measurements in control sera by isotope dilution/mass spectrometry: proposed definitive method compared with a reference method

    International Nuclear Information System (INIS)

    Pelletier, O.; Arratoon, C.

    1987-01-01

    This improved isotope-dilution gas chromatographic/mass spectrometric (GC/MS) method, in which [ 13 C]glucose is the internal standard, meets the requirements of a Definitive Method. In a first study with five reconstituted lyophilized sera, a nested analysis of variance of GC/MS values indicated considerable among-vial variation. The CV for 32 measurements per serum ranged from 0.5 to 0.9%. However, concentration and uncertainty values (mmol/L per gram of serum) assigned to one serum by the NBS Definitive Method (7.56 +/- 0.28) were practically identical to those obtained with the proposed method (7.57 +/- 0.20). In the second study, we used twice more [ 13 C]glucose diluent to assay four serum pools and two lyophilized sera. The CV ranged from 0.26 to 0.5% for the serum pools and from 0.28 to 0.59% for the lyophilized sera. In comparison, results by the hexokinase/glucose-6-phosphate dehydrogenase reference method agreed within acceptable limits with those by the Definitive Method but tended to be slightly higher (up to 3%) for lyophilized serum samples or slightly lower (up to 2.5%) for serum pools

  2. Electron-Positron Accumulator (EPA)

    CERN Multimedia

    Photographic Service

    1986-01-01

    After acceleration in the low-current linac LIL-W, the electrons and positrons are accumulated in EPA to obtain a sufficient intensity and a suitable time-structure, before being passed on to the PS for further acceleration to 3.5 GeV. Electrons circulate from right to left, positrons in the other direction. Dipole bending magnets are red, focusing quadrupoles blue, sextupoles for chromaticity-control orange. The vertical tube at the left of the picture belongs to an optical transport system carrying the synchrotron radiation to detectors for beam size measurement. Construction of EPA was completed in spring 1986. LIL-W and EPA were conceived for an energy of 600 MeV, but operation was limited to 500 MeV.

  3. Efficient implementation of three-dimensional reference interaction site model self-consistent-field method: application to solvatochromic shift calculations.

    Science.gov (United States)

    Minezawa, Noriyuki; Kato, Shigeki

    2007-02-07

    The authors present an implementation of the three-dimensional reference interaction site model self-consistent-field (3D-RISM-SCF) method. First, they introduce a robust and efficient algorithm for solving the 3D-RISM equation. The algorithm is a hybrid of the Newton-Raphson and Picard methods. The Jacobian matrix is analytically expressed in a computationally useful form. Second, they discuss the solute-solvent electrostatic interaction. For the solute to solvent route, the electrostatic potential (ESP) map on a 3D grid is constructed directly from the electron density. The charge fitting procedure is not required to determine the ESP. For the solvent to solute route, the ESP acting on the solute molecule is derived from the solvent charge distribution obtained by solving the 3D-RISM equation. Matrix elements of the solute-solvent interaction are evaluated by the direct numerical integration. A remarkable reduction in the computational time is observed in both routes. Finally, the authors implement the first derivatives of the free energy with respect to the solute nuclear coordinates. They apply the present method to "solute" water and formaldehyde in aqueous solvent using the simple point charge model, and the results are compared with those from other methods: the six-dimensional molecular Ornstein-Zernike SCF, the one-dimensional site-site RISM-SCF, and the polarizable continuum model. The authors also calculate the solvatochromic shifts of acetone, benzonitrile, and nitrobenzene using the present method and compare them with the experimental and other theoretical results.

  4. A comparative uncertainty study of the calibration of macrolide antibiotic reference standards using quantitative nuclear magnetic resonance and mass balance methods

    International Nuclear Information System (INIS)

    Liu Shuyu; Hu Changqin

    2007-01-01

    This study introduces the general method of quantitative nuclear magnetic resonance (qNMR) for the calibration of reference standards of macrolide antibiotics. Several qNMR experimental conditions were optimized including delay, which is an important parameter of quantification. Three kinds of macrolide antibiotics were used to validate the accuracy of the qNMR method by comparison with the results obtained by the high performance liquid chromatography (HPLC) method. The purities of five common reference standards of macrolide antibiotics were measured by the 1 H qNMR method and the mass balance method, respectively. The analysis results of the two methods were compared. The qNMR is quick and simple to use. In a new medicine research and development process, qNMR provides a new and reliable method for purity analysis of the reference standard

  5. Improvement of the banana "Musa acuminata" reference sequence using NGS data and semi-automated bioinformatics methods.

    Science.gov (United States)

    Martin, Guillaume; Baurens, Franc-Christophe; Droc, Gaëtan; Rouard, Mathieu; Cenci, Alberto; Kilian, Andrzej; Hastie, Alex; Doležel, Jaroslav; Aury, Jean-Marc; Alberti, Adriana; Carreel, Françoise; D'Hont, Angélique

    2016-03-16

    Recent advances in genomics indicate functional significance of a majority of genome sequences and their long range interactions. As a detailed examination of genome organization and function requires very high quality genome sequence, the objective of this study was to improve reference genome assembly of banana (Musa acuminata). We have developed a modular bioinformatics pipeline to improve genome sequence assemblies, which can handle various types of data. The pipeline comprises several semi-automated tools. However, unlike classical automated tools that are based on global parameters, the semi-automated tools proposed an expert mode for a user who can decide on suggested improvements through local compromises. The pipeline was used to improve the draft genome sequence of Musa acuminata. Genotyping by sequencing (GBS) of a segregating population and paired-end sequencing were used to detect and correct scaffold misassemblies. Long insert size paired-end reads identified scaffold junctions and fusions missed by automated assembly methods. GBS markers were used to anchor scaffolds to pseudo-molecules with a new bioinformatics approach that avoids the tedious step of marker ordering during genetic map construction. Furthermore, a genome map was constructed and used to assemble scaffolds into super scaffolds. Finally, a consensus gene annotation was projected on the new assembly from two pre-existing annotations. This approach reduced the total Musa scaffold number from 7513 to 1532 (i.e. by 80%), with an N50 that increased from 1.3 Mb (65 scaffolds) to 3.0 Mb (26 scaffolds). 89.5% of the assembly was anchored to the 11 Musa chromosomes compared to the previous 70%. Unknown sites (N) were reduced from 17.3 to 10.0%. The release of the Musa acuminata reference genome version 2 provides a platform for detailed analysis of banana genome variation, function and evolution. Bioinformatics tools developed in this work can be used to improve genome sequence assemblies in

  6. Determination of uncertainty of automated emission measuring systems under field conditions using a second method as a reference

    Energy Technology Data Exchange (ETDEWEB)

    Puustinen, H.; Aunela-Tapola, L.; Tolvanen, M.; Vahlman, T. [VTT Chemical Technology, Espoo (Finland). Environmental Technology; Kovanen, K. [VTT Building Technology, Espoo (Finland). Building Physics, Building Services and Fire Technology

    1999-09-01

    This report presents a procedure to determine the uncertainty of an automated emission measuring system (AMS) by comparing the results with a second method (REF). The procedure determines the uncertainty of AMS by comparing the final concentration and emission results of AMS and REF. In this way, the data processing of the plant is included in the result evaluation. This procedure assumes that the uncertainty of REF is known and determined in due form. The uncertainty determination has been divided into two cases; varying and nearly constant concentration. The suggested procedure calculates the uncertainty of AMS at the 95 % confidence level by a tabulated t-value. A minimum of three data pairs is required. However, a higher amount of data pairs is desirable, since a low amount of data pairs results in a higher uncertainty of AMS. The uncertainty of AMS is valid only within the range of concentrations at which the tests were carried out. Statistical data processing shows that the uncertainty of the reference method has a significant effect on the uncertainty of AMS, which always becomes larger than the uncertainty of REF. This should be taken into account when testing whether AMS fulfils the given uncertainty limits. Practical details, concerning parallel measurements at the plant, and the costs of the measurement campaign, have been taken into account when suggesting alternative ways for implementing the comparative measurements. (orig.) 6 refs.

  7. Methods and Sources of Data Used to Develop Selected Water-Quality Indicators for Streams and Ground Water for EPA's 2007 Report on the Environment: Science Report

    Science.gov (United States)

    Baker, Nancy T.; Wilson, John T.; Moran, Michael J.

    2008-01-01

    The U.S. Geological Survey (USGS) was one of numerous governmental agencies, private organizations, and the academic community that provided data and interpretations for the U.S. Environmental Protection Agency?s (USEPA) 2007 Report on the Environment: Science Report. This report documents the sources of data and methods used to develop selected water?quality indicators for the 2007 edition of the report compiled by USEPA. Stream and ground?water?quality data collected nationally in a consistent manner as part of the USGS?s National Water?Quality Assessment Program (NAWQA) were provided for several water?quality indicators, including Nitrogen and Phosphorus in Streams in Agricultural Watersheds; Pesticides in Streams in Agricultural Watersheds; and Nitrate and Pesticides in Shallow Ground Water in Agricultural Watersheds. In addition, the USGS provided nitrate (nitrate plus nitrite) and phosphorus riverine load estimates calculated from water?quality and streamflow data collected as part of its National Stream Water Quality Accounting Network (NASQAN) and its Federal?State Cooperative Program for the Nitrogen and Phosphorus Discharge from Large Rivers indicator.

  8. EPA Principles for Greener Cleanups

    Science.gov (United States)

    A goal of the U.S. Environmental Protection Agency (EPA) Office and Land and Emergency Management (OLEM) and its many partners is to preserve and restore land by promoting and using protective waste management practices and by assessing and cleaning..

  9. GET SMART: EPA'S SMARTE INITIATIVE

    Science.gov (United States)

    The EPA's Office of Research and Development with the assistance of the U.S.-German Bilateral Working Group and the Interstate Technology Regulatory Council (ITRC), is developing Site-specific Management Approaches and Revitalization Tools (SMART) that will help stakeholders over...

  10. EPA Research in Alaska

    Science.gov (United States)

    EPA’s collaboration with the DEC and the Air Force on PFAS sampling and analytical methods is key to ensuring valid, defensible data are collected on these emerging contaminants that are being found in soil, groundwater and drinking water in Alaska.

  11. 76 FR 26616 - Wisconsin: Incorporation by Reference of Approved State Hazardous Waste Management Program

    Science.gov (United States)

    2011-05-09

    ... Reference of Approved State Hazardous Waste Management Program AGENCY: Environmental Protection Agency (EPA... (RCRA) allows EPA to authorize States to operate their hazardous waste management programs in lieu of the Federal program. EPA uses the regulations entitled ``Approved State Hazardous Waste Management...

  12. 76 FR 26681 - Wisconsin: Incorporation by Reference of Approved State Hazardous Waste Management Program

    Science.gov (United States)

    2011-05-09

    ... of Approved State Hazardous Waste Management Program AGENCY: Environmental Protection Agency (EPA... Hazardous Waste Management Programs,'' Wisconsin's authorized hazardous waste program. EPA will incorporate... that are authorized and that the EPA will enforce under the Solid Waste Disposal Act, commonly referred...

  13. EPA Region 1 Environmentally Sensitive Areas

    Data.gov (United States)

    U.S. Environmental Protection Agency — This coverage represents polygon equivalents of environmentally sensitive areas (ESA) in EPA Region I. ESAs were developed as part of an EPA headquarters initiative...

  14. U.S. EPA Metadata Editor (EME)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA Metadata Editor (EME) allows users to create geospatial metadata that meets EPA's requirements. The tool has been developed as a desktop application that...

  15. EPA Linked Open Data: Substance Registry Service

    Data.gov (United States)

    U.S. Environmental Protection Agency — Substance Registry Services (SRS) is the Environmental Protection Agency's (EPA) central system for information about substances that are tracked or regulated by EPA...

  16. 2011 EPA Pesticide General Permit (PGP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The 2011 EPA Pesticide General Permit (PGP) covers discharges of biological pesticides, and chemical pesticides that leave a residue, in areas where EPA is the NPDES...

  17. EPA's role in uranium mining and milling

    International Nuclear Information System (INIS)

    Smith, P.B.

    1980-01-01

    EPA's role and actions in regulating uranium mining and milling are reviewed and updated. Special emphasis is given to EPA's current activities under the Uranium Mill Tailings Radiation Control Act of 1978

  18. EPA METHODS FOR VIRUS DETECTION IN WATER

    Science.gov (United States)

    A number of different types of human enteric viruses cause waterborne outbreaks when individuals are exposed to contaminated drinking and recreational waters. Members of the enterovirus group cause numerous diseases, including gastroenteritis, encephalitis, meningitis, myocard...

  19. An analytic-numerical method for the construction of the reference law of operation for a class of mechanical controlled systems

    Science.gov (United States)

    Mizhidon, A. D.; Mizhidon, K. A.

    2017-04-01

    An analytic-numerical method for the construction of a reference law of operation for a class of dynamic systems describing vibrations in controlled mechanical systems is proposed. By the reference law of operation of a system, we mean a law of the system motion that satisfies all the requirements for the quality and design features of the system under permanent external disturbances. As disturbances, we consider polyharmonic functions with known amplitudes and frequencies of the harmonics but unknown initial phases. For constructing the reference law of motion, an auxiliary optimal control problem is solved in which the cost function depends on a weighting coefficient. The choice of the weighting coefficient ensures the design of the reference law. Theoretical foundations of the proposed method are given.

  20. Comparison study for the CCME reference method for determination of PHC in soil by using internal and external standard methods and by using silica gel column cleanup and in-situ silica gel cleanup methods

    International Nuclear Information System (INIS)

    Wang, Z.; Fingas, M.; Sigouin, L.; Yang, C.; Hollebone, B.

    2003-01-01

    The assessment, cleanup, and remediation of hydrocarbon contaminated sites is covered in the Reference Method for Canada-Wide Standard for Petroleum Hydrocarbons-Tier 1 Method. It replaces several analytical methods used in the past by some laboratories and jurisdictions in Canada. The authors conducted two comparative evaluations to validate the Tier 1 Analytical Method. The first compared the Internal and External Standard Methods, and the second compared the Silica Gel Column Cleanup Method with the In-situ Silica Gel Cleanup Method. The Canadian Council of Ministers of the Environment (CCME) Tier 1 Method recommends and requires the External Standard Method to determine petroleum hydrocarbons (PHC) in soil samples. The Internal Method is widely used to quantify various organic and inorganic pollutants in environmental samples. The Tier 1 Method offers two options for the same extract cleanup. They are: Option A - In-situ Silica Gel Cleanup, and Option B - Silica Gel Column Cleanup. Linearity, precision, and PHC quantification results were the parameters considered for diesel and motor oil solutions, for diesel spiked soil samples, and for motor oil spiked soil samples. It was concluded that both the External and Internal Standard Methods for gas chromatograph (GC) determination of PHC in soil possess their own advantages. The PHC results obtained using the In-Situ Silica Gel Cleanup Method were lower than those obtained with the Silica Gel Column Cleanup Methods. The more efficient and effective sample cleanup method proved to be the Silica Gel Column Method. 13 refs., 7 tabs., 7 figs

  1. Custom Search | ECHO | US EPA

    Science.gov (United States)

    ECHO, Enforcement and Compliance History Online, provides compliance and enforcement information for approximately 800,000 EPA-regulated facilities nationwide. ECHO includes permit, inspection, violation, enforcement action, and penalty information about facilities regulated under the Clean Air Act (CAA) Stationary Source Program, Clean Water Act (CWA) National Pollutant Elimination Discharge System (NPDES), and/or Resource Conservation and Recovery Act (RCRA). Information also is provided on surrounding demographics when available.

  2. Watershed Statistics | ECHO | US EPA

    Science.gov (United States)

    ECHO, Enforcement and Compliance History Online, provides compliance and enforcement information for approximately 800,000 EPA-regulated facilities nationwide. ECHO includes permit, inspection, violation, enforcement action, and penalty information about facilities regulated under the Clean Air Act (CAA) Stationary Source Program, Clean Water Act (CWA) National Pollutant Elimination Discharge System (NPDES), and/or Resource Conservation and Recovery Act (RCRA). Information also is provided on surrounding demographics when available.

  3. Low Frequencies of Interference to EPA Quantitative Polymerase Chain Reaction (qPCR) Methods for Microbial Water Quality Monitoring in U.S. Rivers and Streams and Coastal Waters

    Science.gov (United States)

    In collaboration with U.S States and Tribes, the United States Environmental Protection Agency (EPA) conducts periodic and rotating, statistically based surveys of U.S. rivers and streams (National Rivers and Streams Assessment, NRSA), estuarine and Great Lakes nearshore coastal ...

  4. Journal Article: Average Method Blank Quantities of Dioxin-Like Congeners and Their Relationship to the Detection Limits of the U.S. EPA's National Dioxin Air Monitoring Network (Ndamn)

    Science.gov (United States)

    The U.S. EPA established a National Dioxin Air Monitoring Network (NDAMN) to determine the temporal and geographical variability of atmospheric CDDs, CDFs and coplanar PCBs throughout the United States. Currently operating at 33 stations, NDAMN has, as one of its tasks, the dete...

  5. Serum prolactin revisited: parametric reference intervals and cross platform evaluation of polyethylene glycol precipitation-based methods for discrimination between hyperprolactinemia and macroprolactinemia.

    Science.gov (United States)

    Overgaard, Martin; Pedersen, Susanne Møller

    2017-10-26

    Hyperprolactinemia diagnosis and treatment is often compromised by the presence of biologically inactive and clinically irrelevant higher-molecular-weight complexes of prolactin, macroprolactin. The objective of this study was to evaluate the performance of two macroprolactin screening regimes across commonly used automated immunoassay platforms. Parametric total and monomeric gender-specific reference intervals were determined for six immunoassay methods using female (n=96) and male sera (n=127) from healthy donors. The reference intervals were validated using 27 hyperprolactinemic and macroprolactinemic sera, whose presence of monomeric and macroforms of prolactin were determined using gel filtration chromatography (GFC). Normative data for six prolactin assays included the range of values (2.5th-97.5th percentiles). Validation sera (hyperprolactinemic and macroprolactinemic; n=27) showed higher discordant classification [mean=2.8; 95% confidence interval (CI) 1.2-4.4] for the monomer reference interval method compared to the post-polyethylene glycol (PEG) recovery cutoff method (mean=1.8; 95% CI 0.8-2.8). The two monomer/macroprolactin discrimination methods did not differ significantly (p=0.089). Among macroprolactinemic sera evaluated by both discrimination methods, the Cobas and Architect/Kryptor prolactin assays showed the lowest and the highest number of misclassifications, respectively. Current automated immunoassays for prolactin testing require macroprolactin screening methods based on PEG precipitation in order to discriminate truly from falsely elevated serum prolactin. While the recovery cutoff and monomeric reference interval macroprolactin screening methods demonstrate similar discriminative ability, the latter method also provides the clinician with an easy interpretable monomeric prolactin concentration along with a monomeric reference interval.

  6. Validating fatty acid intake as estimated by an FFQ: how does the 24 h recall perform as reference method compared with the duplicate portion?

    Science.gov (United States)

    Trijsburg, Laura; de Vries, Jeanne Hm; Hollman, Peter Ch; Hulshof, Paul Jm; van 't Veer, Pieter; Boshuizen, Hendriek C; Geelen, Anouk

    2018-05-08

    To compare the performance of the commonly used 24 h recall (24hR) with the more distinct duplicate portion (DP) as reference method for validation of fatty acid intake estimated with an FFQ. Intakes of SFA, MUFA, n-3 fatty acids and linoleic acid (LA) were estimated by chemical analysis of two DP and by on average five 24hR and two FFQ. Plasma n-3 fatty acids and LA were used to objectively compare ranking of individuals based on DP and 24hR. Multivariate measurement error models were used to estimate validity coefficients and attenuation factors for the FFQ with the DP and 24hR as reference methods. Wageningen, the Netherlands. Ninety-two men and 106 women (aged 20-70 years). Validity coefficients for the fatty acid estimates by the FFQ tended to be lower when using the DP as reference method compared with the 24hR. Attenuation factors for the FFQ tended to be slightly higher based on the DP than those based on the 24hR as reference method. Furthermore, when using plasma fatty acids as reference, the DP showed comparable to slightly better ranking of participants according to their intake of n-3 fatty acids (0·33) and n-3:LA (0·34) than the 24hR (0·22 and 0·24, respectively). The 24hR gives only slightly different results compared with the distinctive but less feasible DP, therefore use of the 24hR seems appropriate as the reference method for FFQ validation of fatty acid intake.

  7. Evaluation of the reference unit method for herbaceous biomass estimation in native grasslands of southwestern South Dakota

    Science.gov (United States)

    Eric D. Boyda

    2013-01-01

    The high costs associated with physically harvesting plant biomass may prevent sufficient data collection, which is necessary to account for the natural variability of vegetation at a landscape scale. A biomass estimation technique was previously developed using representative samples or "reference units", which eliminated the need to harvest biomass from all...

  8. A new method to compensate impedance artefacts for Li-ion batteries with integrated micro-reference electrodes

    NARCIS (Netherlands)

    Raijmakers, L.H.J.; Notten, P.H.L.; Lammers, M.J.G.

    2017-01-01

    In order to measure the electrochemical characteristics of both electrodes inside Li-ion batteries, micro-reference electrodes (μREF) turned out to be very useful. However, measuring the electrochemical impedance with respect to μREF can lead to severe measurement artefacts, making a detailed

  9. Low-level and narm radioactive wastes. Model documentation: accounting model for PRESTO-EPA-POP, PRESTO-EPA-DEEP, and PRESTO-EPA-BRC. Methodology and users manual. Final report

    International Nuclear Information System (INIS)

    Rogers, V.; Hung, C.

    1987-12-01

    The accounting model was used as a utility model for assessing the cumulative health effects to the general population residing in the downstream regional water basin as a result of the disposal of LLW when a unit response analysis method is used. The utility model is specifically designed to assess the cumulative population health effects in conjunction with the PRESTO-EPA-POP, PRESTO-EPA-BRC, or PRESTO-EPA-DEEP model simply for the purpose of reducing the cost of analysis. Therefore, the assessment of the cumulative population health effects may also be conducted with one of the above appropriate models without the aid of this accounting model

  10. Growth references

    NARCIS (Netherlands)

    Buuren, S. van

    2007-01-01

    A growth reference describes the variation of an anthropometric measurement within a group of individuals. A reference is a tool for grouping and analyzing data and provides a common basis for comparing populations.1 A well known type of reference is the age-conditional growth diagram. The

  11. Use of reference materials for validating analytical methods. Applied to the determination of As, Co, Na, Hg, Se and Fe using neutron activation analysis

    International Nuclear Information System (INIS)

    Munoz, L; Andonie, O; Kohnenkamp, I

    2000-01-01

    The main purpose of an analytical laboratory is to provide reliable information on the nature and composition of the materials submitted for analysis. This purpose can only be attained if analytical methodologies that have the attributes of accuracy, precision, specificity and sensitivity, among others, are used. The process by which these attributes are evaluated is called validation of the analytical method. The Chilean Nuclear Energy Commission's Neutron Activation Analysis Laboratory is applying a quality guarantee program to ensure the quality of its analytical results, which aims, as well, to attain accreditation for some of its measurements. Validation of the analytical methodologies used is an essential part of applying this program. There are many forms of validation, from comparison with reference techniques to participation in inter-comparison rounds. Certified reference materials were used in this work in order to validate the application of neutron activation analysis in determining As, Co, Na, Hg, Se and Fe in shellfish samples. The use of reference materials was chosen because it is a simple option that easily detects sources of systematic errors. Neutron activation analysis is an instrumental analytical method that does not need chemical treatment and that is based on processes which take place in the nuclei of atoms, making the matrix effects unimportant and different biological reference materials can be used. The following certified reference materials were used for validating the method used: BCR human hair 397, NRCC dogfish muscle DORM-2, NRCC -dogfish liver DOLT-2, NIST - oyster tissue 1566, NIES - mussel 6 and BCR - tuna fish 464. The reference materials were analyzed using the procedure developed for the shellfish samples and the above-mentioned elements were determined. With the results obtained, the parameters of accuracy, precision, detection limit, quantification limit and uncertainty associated with the method were determined for each

  12. US EPA Region 4 RMP Facilities

    Science.gov (United States)

    To improve public health and the environment, the United States Environmental Protection Agency (USEPA) collects information about facilities, sites, or places subject to environmental regulation or of environmental interest. Through the Geospatial Data Download Service, the public is now able to download the EPA Geodata shapefile containing facility and site information from EPA's national program systems. The file is Internet accessible from the Envirofacts Web site (http://www.epa.gov/enviro). The data may be used with geospatial mapping applications. (Note: The shapefile omits facilities without latitude/longitude coordinates.) The EPA Geospatial Data contains the name, location (latitude/longitude), and EPA program information about specific facilities and sites. In addition, the file contains a Uniform Resource Locator (URL), which allows mapping applications to present an option to users to access additional EPA data resources on a specific facility or site.

  13. A candidate liquid chromatography mass spectrometry reference method for the quantification of the cardiac marker 1-32 B-type natriuretic peptide.

    Science.gov (United States)

    Torma, Attila F; Groves, Kate; Biesenbruch, Sabine; Mussell, Chris; Reid, Alan; Ellison, Steve; Cramer, Rainer; Quaglia, Milena

    2017-08-28

    B-type natriuretic peptide (BNP) is a 32 amino acid cardiac hormone routinely measured by immunoassays to diagnose heart failure. While it is reported that immunoassay results can vary up to 45%, no attempt of standardization and/or harmonization through the development of certified reference materials (CRMs) or reference measurement procedures (RMPs) has yet been carried out. B-type natriuretic peptide primary calibrator was quantified traceably to the International System of Units (SI) by both amino acid analysis and tryptic digestion. A method for the stabilization of BNP in plasma followed by protein precipitation, solid phase extraction (SPE) and liquid chromatography (LC) mass spectrometry (MS) was then developed and validated for the quantification of BNP at clinically relevant concentrations (15-150 fmol/g). The candidate reference method was applied to the quantification of BNP in a number of samples from the UK NEQAS Cardiac Markers Scheme to demonstrate its applicability to generate reference values and to preliminary evaluate the commutability of a potential CRM. The results from the reference method were consistently lower than the immunoassay results and discrepancy between the immunoassays was observed confirming previous data. The application of the liquid chromatography-mass spectrometry (LC-MS) method to the UK NEQAS samples and the correlation of the results with the immunoassay results shows the potential of the method to support external quality assessment schemes, to improve understanding of the bias of the assays and to establish RMPs for BNP measurements. Furthermore, the method has the potential to be multiplexed for monitoring circulating truncated forms of BNP.

  14. The Effect of Matrix Method on Anxiety and Attitude Toward Methamphetamine and Crack Abuse in Males Referring to Addiction Treatment Centers in Tonkabon, Iran

    Directory of Open Access Journals (Sweden)

    Hemmati Sabet

    2015-11-01

    Full Text Available Background Drug abuse is a major problem in the communities and has many harmful effects on human body. Objectives The current study aimed to compare the efficacy of matrix method on anxiety and attitude of male crack abusers referred to addiction treatment centers in Tonkabon, Iran, in 2014. Patients and Methods The current semi -experimental study included 1,000 males referred to addiction treatment centers in Tonkabon with crack abuse history in 2014. Based on Morgan sample volume formula, 278 males with anxiety and higher attitude to drug abuse were randomly selected from 1,000 males referred to addiction treatment centers in Tonkabon. Then, 30 subjects were reselected out of them and equally assigned into two groups of experimental and control, 15 subjects in each group. The experimental group received 24 sessions of 30 - 60 minutes matrix treatment method in group, but the control group received no training. At the end of training period the post-test was carried out. The research findings confirmed the efficacy of matrix method on anxiety and attitude to crack abuse among those referring to the addition treatment center. Results The single covariance analysis of ANCOVA indicated that the value of Eta about 72% of variance of anxiety variable and about 76% of variance of drug abuse variable are taken in to account for variable of group. The intervention was effective in reducing anxiety and attitude to crack in males. Evaluating the adjusted mean showed the effectiveness of matrix method on anxiety and attitude to crack abuse in males. Conclusions The research result showed that matrix method affected the reduction of methamphetamine and attitude to crack abuse in males referred to the addition treatment center.

  15. Survey of total error of precipitation and homogeneous HDL-cholesterol methods and simultaneous evaluation of lyophilized saccharose-containing candidate reference materials for HDL-cholesterol

    NARCIS (Netherlands)

    C.M. Cobbaert (Christa); H. Baadenhuijsen; L. Zwang (Louwerens); C.W. Weykamp; P.N. Demacker; P.G.H. Mulder (Paul)

    1999-01-01

    textabstractBACKGROUND: Standardization of HDL-cholesterol is needed for risk assessment. We assessed for the first time the accuracy of HDL-cholesterol testing in The Netherlands and evaluated 11 candidate reference materials (CRMs). METHODS: The total error (TE) of

  16. Preparation of an In-House Reference Material Containing Fumonisins in Thai Rice and Matrix Extension of the Analytical Method for Japanese Rice

    Science.gov (United States)

    Awaludin, Norhafniza; Nagata, Reiko; Kawasaki, Tomomi; Kushiro, Masayo

    2009-01-01

    Mycotoxin contamination in rice is less reported, compared to that in wheat or maize, however, some Fusarium fungi occasionally infect rice in the paddy field. Fumonisins are mycotoxins mainly produced by Fusarium verticillioides, which often ruins maize. Rice adherent fungus Gibberella fujikuroi is taxonomically near to F. verticillioides, and there are sporadic reports of fumonisin contamination in rice from Asia, Europe and the United States. Therefore, there exists the potential risk of fumonisin contamination in rice as well as the need for the validated analytical method for fumonisins in rice. Although both natural and spiked reference materials are available for some Fusarium mycotoxins in matrices of wheat and maize, there are no reference materials for Fusarium mycotoxins in rice. In this study, we have developed a method for the preparation of a reference material containing fumonisins in Thai rice. A ShakeMaster grinding machine was used for the preparation of a mixed material of blank Thai rice and F. verticillioides-infected Thai rice. The homogeneity of the mixed material was confirmed by one-way analysis of variance, which led this material to serve as an in-house reference material. Using this reference material, several procedures to extract fumonisins from Thai rice were compared. Accordingly, we proved the applicability of an effective extraction procedure for the determination of fumonisins in Japanese rice. PMID:22069540

  17. Certification of caffeine reference material purity by ultraviolet/visible spectrophotometry and high-performance liquid chromatography with diode-array detection as two independent analytical methods.

    Science.gov (United States)

    Shehata, A B; Rizk, M S; Rend, E A

    2016-10-01

    Caffeine reference material certified for purity is produced worldwide, but no research work on the details of the certification process has been published in the literature. In this paper, we report the scientific details of the preparation and certification of pure caffeine reference materials. Caffeine was prepared by extraction from roasted and ground coffee by dichloromethane after heating in deionized water mixed with magnesium oxide. The extract was purified, dried, and bottled in dark glass vials. Stratified random selection was applied to select a number of vials for homogeneity and stability studies, which revealed that the prepared reference material is homogeneous and sufficiently stable. Quantification of caffeine purity % was carried out using a calibrated UV/visible spectrophotometer and a calibrated high-performance liquid chromatography with diode-array detection method. The results obtained from both methods were combined to drive the certified value and its associated uncertainty. The certified value of the reference material purity was found to be 99.86% and its associated uncertainty was ±0.65%, which makes the candidate reference material a very useful calibrant in food and drug chemical analysis. Copyright © 2016. Published by Elsevier B.V.

  18. Certification of caffeine reference material purity by ultraviolet/visible spectrophotometry and high-performance liquid chromatography with diode-array detection as two independent analytical methods

    Directory of Open Access Journals (Sweden)

    A.B. Shehata

    2016-10-01

    Full Text Available Caffeine reference material certified for purity is produced worldwide, but no research work on the details of the certification process has been published in the literature. In this paper, we report the scientific details of the preparation and certification of pure caffeine reference materials. Caffeine was prepared by extraction from roasted and ground coffee by dichloromethane after heating in deionized water mixed with magnesium oxide. The extract was purified, dried, and bottled in dark glass vials. Stratified random selection was applied to select a number of vials for homogeneity and stability studies, which revealed that the prepared reference material is homogeneous and sufficiently stable. Quantification of caffeine purity % was carried out using a calibrated UV/visible spectrophotometer and a calibrated high-performance liquid chromatography with diode-array detection method. The results obtained from both methods were combined to drive the certified value and its associated uncertainty. The certified value of the reference material purity was found to be 99.86% and its associated uncertainty was ±0.65%, which makes the candidate reference material a very useful calibrant in food and drug chemical analysis.

  19. New EPA ban stymies Canadian exports of PCB waste

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    With reference to a 1996 EPA ruling permitting the importation to the USA of PCBs for incineration, a unanimous three-judge panel of the US Court of Appeals for the Ninth District in San Francisco ruled that the Environmental Protection Agency (EPA) did not have the authority to permit the import of PCB wastes into the USA for disposal. Prior to the decision, 35 applications from Canada to export some 37,000 tonnes of PCB to the USA for disposal have been approved. Canadian brokers are upset with the decision, claiming that the decision will create a virtual monopoly for Bovar Inc., of Calgary, the only PCB-disposal facility in Canada. The loss (at least for the time being) of the alternate disposal opportunity will likely have the effect of forcing Canadian customers to pay more for PCB disposal. The Canadian government is monitoring the situation and is waiting to see whether an appeal is filed against the ruling

  20. Comments on EPA's LLW preproposal

    International Nuclear Information System (INIS)

    Littleton, B.K.; Weinstock, L.

    1995-01-01

    The Environmental Protection Agency (EPA) is currently developing standards for the management, storage, and disposal of Low-Level Radioactive Waste (LLW). The Atomic Energy Act delegated EPA, among other provisions, the authority to establish generally applicable standards for the disposal of radioactive waste to ensure that the public and the environment are adequately protected from potential radiation impacts. As an initial effort to open communications on a standard for LLW, the Agency developed a preproposal draft (Preproposal Draft of 40 CFR Part 193 - 30 Nov 94) and circulated it to interested parties for review and comment. The extended comment period ended April 12, 1995. A summary of the comments received and analyzed to date follows. After all comments have been analyzed, the rule will undergo an Agency clearance process and be sent to the Office of Management and Budget for review. After that review, the formal process of publication of the proposed rule in the Federal Register and the formal public comment period will begin

  1. Agriculture: About EPA's National Agriculture Center

    Science.gov (United States)

    EPA's National Agriculture Center (Ag Center), with the support of the United States Department of Agriculture, serves growers, livestock producers, other agribusinesses, and agricultural information/education providers.

  2. EPA Region 1 Environmentally Sensitive Areas (Points)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This coverage represents point equivalents of environmentally sensitive areas in EPA New England. This coverage represents polygon equivalents of environmentally...

  3. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme.

    Science.gov (United States)

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro

    2016-11-01

    Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) -1.292 ( n = 495, R 2  = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was -0.71%, -0.42% and -0.13%, respectively. For the combined precision, the equation y (CV) = -0.398 × (triglycerides value) + 1.797 ( n = 495, R 2  = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time.

  4. Fecal electrolyte testing for evaluation of unexplained diarrhea: Validation of body fluid test accuracy in the absence of a reference method.

    Science.gov (United States)

    Voskoboev, Nikolay V; Cambern, Sarah J; Hanley, Matthew M; Giesen, Callen D; Schilling, Jason J; Jannetto, Paul J; Lieske, John C; Block, Darci R

    2015-11-01

    Validation of tests performed on body fluids other than blood or urine can be challenging due to the lack of a reference method to confirm accuracy. The aim of this study was to evaluate alternate assessments of accuracy that laboratories can rely on to validate body fluid tests in the absence of a reference method using the example of sodium (Na(+)), potassium (K(+)), and magnesium (Mg(2+)) testing in stool fluid. Validations of fecal Na(+), K(+), and Mg(2+) were performed on the Roche cobas 6000 c501 (Roche Diagnostics) using residual stool specimens submitted for clinical testing. Spiked recovery, mixing studies, and serial dilutions were performed and % recovery of each analyte was calculated to assess accuracy. Results were confirmed by comparison to a reference method (ICP-OES, PerkinElmer). Mean recoveries for fecal electrolytes were Na(+) upon spiking=92%, mixing=104%, and dilution=105%; K(+) upon spiking=94%, mixing=96%, and dilution=100%; and Mg(2+) upon spiking=93%, mixing=98%, and dilution=100%. When autoanalyzer results were compared to reference ICP-OES results, Na(+) had a slope=0.94, intercept=4.1, and R(2)=0.99; K(+) had a slope=0.99, intercept=0.7, and R(2)=0.99; and Mg(2+) had a slope=0.91, intercept=-4.6, and R(2)=0.91. Calculated osmotic gap using both methods were highly correlated with slope=0.95, intercept=4.5, and R(2)=0.97. Acid pretreatment increased magnesium recovery from a subset of clinical specimens. A combination of mixing, spiking, and dilution recovery experiments are an acceptable surrogate for assessing accuracy in body fluid validations in the absence of a reference method. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. 77 FR 59879 - Idaho: Incorporation by Reference of Approved State Hazardous Waste Management Program

    Science.gov (United States)

    2012-10-01

    ...: Incorporation by Reference of Approved State Hazardous Waste Management Program AGENCY: Environmental Protection... ``Approved State Hazardous Waste Management Programs,'' Idaho's authorized hazardous waste program. The EPA... Federal Register, the EPA is codifying and incorporating by reference the State's hazardous waste program...

  6. An aggregate method to calibrate the reference point of cumulative prospect theory-based route choice model for urban transit network

    Science.gov (United States)

    Zhang, Yufeng; Long, Man; Luo, Sida; Bao, Yu; Shen, Hanxia

    2015-12-01

    Transit route choice model is the key technology of public transit systems planning and management. Traditional route choice models are mostly based on expected utility theory which has an evident shortcoming that it cannot accurately portray travelers' subjective route choice behavior for their risk preferences are not taken into consideration. Cumulative prospect theory (CPT), a brand new theory, can be used to describe travelers' decision-making process under the condition of uncertainty of transit supply and risk preferences of multi-type travelers. The method to calibrate the reference point, a key parameter to CPT-based transit route choice model, determines the precision of the model to a great extent. In this paper, a new method is put forward to obtain the value of reference point which combines theoretical calculation and field investigation results. Comparing the proposed method with traditional method, it shows that the new method can promote the quality of CPT-based model by improving the accuracy in simulating travelers' route choice behaviors based on transit trip investigation from Nanjing City, China. The proposed method is of great significance to logical transit planning and management, and to some extent makes up the defect that obtaining the reference point is solely based on qualitative analysis.

  7. Establishment of the upper reference limit for thyroid peroxidase autoantibodies according to the guidelines proposed by the National Academy of Clinical Biochemistry: comparison of five different automated methods.

    Science.gov (United States)

    D'Aurizio, Federica; Metus, Paolo; Polizzi Anselmo, Annalisa; Villalta, Danilo; Ferrari, Anna; Castello, Roberto; Giani, Graziella; Tonutti, Elio; Bizzaro, Nicola; Tozzoli, Renato

    2015-12-01

    The estimation of the upper reference limit (URL) for autoantibodies against thyroid peroxidase (TPOAbs) is a controversial issue, because of an uncertainty associated with the criteria used to correctly define the reference population. In addition, the URL of TPOAbs is method-dependent and often arbitrarily established in current laboratory practice. The aim of this study was to determine the reference limits of TPOAbs in a male sample according to the National Academy of Clinical Biochemistry (NACB) guidelines, and to compare them with those obtained in a female group, for five third-generation commercial-automated immunoassay (IMA) platforms. 120 healthy males and 120 healthy females with NACB-required characteristics (younger than 30 years, TSH between 0.5 and 2.0 mIU/L, normal thyroid ultrasound, absence of thyroid disease and absence of other autoimmune diseases) were studied. Sera were analyzed for TPOAbs concentration using five IMA methods applied in automated analyzers: Immulite 2000 XPi (IMM); Maglumi 2000 Plus (MAG); Kryptor Compact Plus (KRY); Phadia 250 (PHA) and Liaison XL (LIA). A statistically significant difference (p reference group for a disease (such as AITD) that affects mainly females. However, in spite of the harmonization among methods provided by the use of an international standard preparation, the wide dispersion of quantitative results still observed in this study suggests the need for further efforts to better understand the cause of these discrepancies, focusing on TPO antigen preparations as the possible source of variability among different assays.

  8. 77 FR 59758 - Idaho: Incorporation by Reference of Approved State Hazardous Waste Management Program

    Science.gov (United States)

    2012-10-01

    ...: Incorporation by Reference of Approved State Hazardous Waste Management Program AGENCY: Environmental Protection..., (RCRA), allows the Environmental Protection Agency (EPA) to authorize State hazardous waste management... codification of the authorized Idaho hazardous waste management program and incorporates by reference...

  9. On adequacy of reference sample composition to metal oxide composition in spectral analysis by the method of sublimating additions

    International Nuclear Information System (INIS)

    Zakhariya, N.F.; Turulina, O.P.

    1983-01-01

    The problem on adequacy of zirconium dioxide reference samples to analysed samples is considered. The mechanism of impurities evaporation process in the presence of the sublimating addition for elements of different nature is studied and limiting it stages have been found. It is shown that kinetic probability of impurities transfer into the form of more high-volatile compounds depending on conditions of preparing zirconium dioxide samples may not coincide with the thermodynamic one. With this connected are systematic deviations of the analytical signal value for samples of different technological prehistory

  10. Method of evaluation of diagnostics reference levels in computerized tomography; Metodo de avaliacao de niveis de referencia de radiodiagnostico em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  11. Evaluation of Method-Specific Extraction Variability for the Measurement of Fatty Acids in a Candidate Infant/Adult Nutritional Formula Reference Material.

    Science.gov (United States)

    Place, Benjamin J

    2017-05-01

    To address community needs, the National Institute of Standards and Technology has developed a candidate Standard Reference Material (SRM) for infant/adult nutritional formula based on milk and whey protein concentrates with isolated soy protein called SRM 1869 Infant/Adult Nutritional Formula. One major component of this candidate SRM is the fatty acid content. In this study, multiple extraction techniques were evaluated to quantify the fatty acids in this new material. Extraction methods that were based on lipid extraction followed by transesterification resulted in lower mass fraction values for all fatty acids than the values measured by methods utilizing in situ transesterification followed by fatty acid methyl ester extraction (ISTE). An ISTE method, based on the identified optimal parameters, was used to determine the fatty acid content of the new infant/adult nutritional formula reference material.

  12. [Reference citation].

    Science.gov (United States)

    Brkić, Silvija

    2013-01-01

    Scientific and professional papers represent the information basis for scientific research and professional work. References important for the paper should be cited within the text, and listed at the end of the paper. This paper deals with different styles of reference citation. Special emphasis was placed on the Vancouver Style for reference citation in biomedical journals established by the International Committee of Medical Journal Editors. It includes original samples for citing various types of articles, both printed and electronic, as well as recommendations related to reference citation in accordance with the methodology and ethics of scientific research and guidelines for preparing manuscripts for publication.

  13. A comparison of the suitability of patient dosimetry methods for establishing diagnostic dose reference levels and optimisation strategies

    International Nuclear Information System (INIS)

    Gfirtner, Hans; Moores, B. Michael; Stieve, Friedrich E.

    2008-01-01

    For 50 adult patients referred for chest radiography, air kerma at the diaphragm KD, dose area product and entrance skin dose were measured. The air kerma at the diaphragm and the dose area product were determined using Diamentor M4KDK(PTW) which allows measuring air kerma and dose area product simultaneously. For the measurement of entrance skin dose TLDs are used. A 50% variation in dose, incident dose as well as entrance skin dose, was registered for the same patient thickness. The recommendation of ICRP to perform the measurements for DRLs at 'representative patients' and that of the CEC to use 'standard-sized patients' seem to make little sense in the case of chest radiography. It could be demonstrated, that the dose area product is the least appropriate dose quantity for patient measurements and to define dose reference levels. For some radiological examinations like chest, pelvis and lumbar spine the dose area product is even sex dependent. Incident dose and entrance surface dose are of equal quality for patient dose measurements in diagnostic radiography. (author)

  14. Factors influencing superimposition error of 3D cephalometric landmarks by plane orientation method using 4 reference points: 4 point superimposition error regression model.

    Science.gov (United States)

    Hwang, Jae Joon; Kim, Kee-Deog; Park, Hyok; Park, Chang Seo; Jeong, Ho-Gul

    2014-01-01

    Superimposition has been used as a method to evaluate the changes of orthodontic or orthopedic treatment in the dental field. With the introduction of cone beam CT (CBCT), evaluating 3 dimensional changes after treatment became possible by superimposition. 4 point plane orientation is one of the simplest ways to achieve superimposition of 3 dimensional images. To find factors influencing superimposition error of cephalometric landmarks by 4 point plane orientation method and to evaluate the reproducibility of cephalometric landmarks for analyzing superimposition error, 20 patients were analyzed who had normal skeletal and occlusal relationship and took CBCT for diagnosis of temporomandibular disorder. The nasion, sella turcica, basion and midpoint between the left and the right most posterior point of the lesser wing of sphenoidal bone were used to define a three-dimensional (3D) anatomical reference co-ordinate system. Another 15 reference cephalometric points were also determined three times in the same image. Reorientation error of each landmark could be explained substantially (23%) by linear regression model, which consists of 3 factors describing position of each landmark towards reference axes and locating error. 4 point plane orientation system may produce an amount of reorientation error that may vary according to the perpendicular distance between the landmark and the x-axis; the reorientation error also increases as the locating error and shift of reference axes viewed from each landmark increases. Therefore, in order to reduce the reorientation error, accuracy of all landmarks including the reference points is important. Construction of the regression model using reference points of greater precision is required for the clinical application of this model.

  15. Reference values assessment in a Mediterranean population for small dense low-density lipoprotein concentration isolated by an optimized precipitation method

    Directory of Open Access Journals (Sweden)

    Fernández-Cidón B

    2017-06-01

    Full Text Available Bárbara Fernández-Cidón,1–3 Ariadna Padró-Miquel,1 Pedro Alía-Ramos,1 María José Castro-Castro,1 Marta Fanlo-Maresma,4 Dolors Dot-Bach,1 José Valero-Politi,1 Xavier Pintó-Sala,4 Beatriz Candás-Estébanez1 1Clinical Laboratory, Hospital Universitari de Bellvitge, L’Hospitalet de Llobregat, Spain; 2Department of Biochemistry, Molecular Biology and Biomedicine, Autonomous University of Barcelona (UAB, Barcelona, Spain; 3Department of Pharmacotherapy, Pharmacogenetics and Pharmaceutical Technology, Institut d’Investigació Biomèdica de Bellvitge (IDIBELL, L’Hospitalet de Llobregat, Spain; 4Cardiovascular Risk Unit, Hospital Universitari de Bellvitge, L’Hospitalet de Llobregat, Spain Background: High serum concentrations of small dense low-density lipoprotein cholesterol (sd-LDL-c particles are associated with risk of cardiovascular disease (CVD. Their clinical application has been hindered as a consequence of the laborious current method used for their quantification. Objective: Optimize a simple and fast precipitation method to isolate sd-LDL particles and establish a reference interval in a Mediterranean population. Materials and methods: Forty-five serum samples were collected, and sd-LDL particles were isolated using a modified heparin-Mg2+ precipitation method. sd-LDL-c concentration was calculated by subtracting high-density lipoprotein cholesterol (HDL-c from the total cholesterol measured in the supernatant. This method was compared with the reference method (ultracentrifugation. Reference values were estimated according to the Clinical and Laboratory Standards Institute and The International Federation of Clinical Chemistry and Laboratory Medicine recommendations. sd-LDL-c concentration was measured in serums from 79 subjects with no lipid metabolism abnormalities. Results: The Passing–Bablok regression equation is y = 1.52 (0.72 to 1.73 + 0.07x (−0.1 to 0.13, demonstrating no significant statistical differences

  16. Reference peak method for analysis of doublets in gamma-ray spectrometry used in neutron activation analysis

    International Nuclear Information System (INIS)

    Wasek, M.; Cichowlas, A.; Sterlinski, S.; Dybczynski, R.

    2000-01-01

    A simple algebraic method for the quantitative analysis of doublets in gamma-ray spectra from HPGe detectors is presented. The calculation algorithm is accomplished using the Microsoft Excel program. The method does not require any assumptions regarding the shape of the peaks in the spectrum. The possibilities of quantitative analysis of doublets of various intensity ration and separation of ots components are discussed in detail. The practical examples proved the usefulness the method also for the analysis of the closed doublets. (author)

  17. Hispanos en la EPA: Grace Robiou

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  18. Hispanos en la EPA: Fabiola Estrada

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  19. Perfiles de hispanos en la EPA

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente de todos.

  20. Hispanos en la EPA: Nadtya Y. Hong

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  1. Hispanos en la EPA: Matthew Tejada

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  2. Hispanos en la EPA: Joel Corona

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  3. EPA Scientific Knowledge Management Assessment and Needs

    Science.gov (United States)

    A series of activities have been conducted by a core group of EPA scientists from across the Agency. The activities were initiated in 2012 and the focus was to increase the reuse and interoperability of science software at EPA. The need for increased reuse and interoperability ...

  4. EPA Regulation of Bed Bug Pesticides

    Science.gov (United States)

    All pesticides must be registered by EPA before being sold and used in the U.S., other than those that rely on a limited set of active ingredients (so-called minimum risk pesticides). EPA reviews for safety and effectiveness.

  5. 40 CFR 73.52 - EPA recordation.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false EPA recordation. 73.52 Section 73.52... ALLOWANCE SYSTEM Allowance Transfers § 73.52 EPA recordation. (a) General recordation. Except as provided in...) following receipt of an allowance transfer request pursuant to § 73.50, by moving each allowance from the...

  6. EPA perspective on federal facility agreements

    International Nuclear Information System (INIS)

    Grundler, C.

    1988-01-01

    Although DOE's image with Congress and the media concerning environmental compliance may be poor, EPA sees the Department's recent attitude toward the environment as good. DOE and EPA must continue to move forward. In particular, EPA would like to emphasize less study of a problem and more clean-up. Strong, enforceable agreements will allow this goal to be met by letting EPA take more risks in its decision making. Currently EPA is developing an enforcement strategy for Federal facilities. This strategy will address identifying Federal facilities of concern, increasing enforcement and compliance monitoring activities at those facilities, implementing the model agreements, resource planning, and the establishment of an Agency Management System for Federal facilities. There are over 1000 Federal facilities which are listed on the EPA compliance docket. Over 200 Federal facilities are expected to be included on the NPL. Increased EPA attention may increase the ability of the various Federal agencies to obtain the necessary funding. Another subject being addressed by EPA is the liability of government contractors under the environmental statutes. The Agency is developing a GoCo enforcement strategy. In the hazardous waste enforcement program, three criteria are being considered for determining when to proceed against a contractor: Degree of contractor control over the hazardous waste management activity. Who is actually performing the work, and Degree of Departmental cooperation

  7. Determination of rare earth and uranium in reference biological materials certified by the method of neutron activation analysis

    International Nuclear Information System (INIS)

    Pereira, Lais H.P.; Saiki, Mitiko

    2013-01-01

    The objective of this study was to evaluate the precision and accuracy of the determinations of Sc, La, Ce, Nd, Sm, Eu, Tb, Yb, Lu and U in certified reference materials (CRMs). To solve the problem of interference from fission products of U in the determination of lanthanides were obtained correction factors for this interference for 140 La, 141 Ce, 143 Ce, 153 Sm and 147 Nd. The experimental procedure of Neutron Activation Analysis consisted of irradiating aliquots of each of the CRMs with synthetic standards of elements under thermal neutron flux of the IEA-R1 nuclear reactor, followed by gamma-ray spectrometry using a high-resolution hyperpurity GE detector. The analyzes of CRMs indicate good accuracy and precision of results, demonstrating the feasibility of applying of established procedure in NAA of elements studied in organic vegetable matrices

  8. Impact of age, sex, and indexation method on MR left ventricular reference values in the Framingham Heart Study offspring cohort.

    Science.gov (United States)

    Yeon, Susan B; Salton, Carol J; Gona, Philimon; Chuang, Michael L; Blease, Susan J; Han, Yuchi; Tsao, Connie W; Danias, Peter G; Levy, Daniel; O'Donnell, Christopher J; Manning, Warren J

    2015-04-01

    To determine normative values for left ventricular (LV) volumes, mass, concentricity, and ejection fraction (EF) and investigate associations between sex, age, and body size with LV parameters in community-dwelling adults. In all, 1794 Framingham Heart Study Offspring cohort members underwent LV short-axis oriented, contiguous multislice cine steady-state free precession MR of the left ventricle; from these a healthy referent group (n = 852, 61 ± 9 years, 40% men) free of clinical cardiac disease and hypertension (SBP 65 years); LV parameters were indexed to measures of body size. Men have greater LV volumes and mass than women both before and after indexation to height, powers of height, and body surface area (P J. Magn. Reson. Imaging 2015;41:1038-1045. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  9. Reference Assessment

    Science.gov (United States)

    Bivens-Tatum, Wayne

    2006-01-01

    This article presents interesting articles that explore several different areas of reference assessment, including practical case studies and theoretical articles that address a range of issues such as librarian behavior, patron satisfaction, virtual reference, or evaluation design. They include: (1) "Evaluating the Quality of a Chat Service"…

  10. Japanese Society for Laboratory Hematology flow cytometric reference method of determining the differential leukocyte count: external quality assurance using fresh blood samples.

    Science.gov (United States)

    Kawai, Y; Nagai, Y; Ogawa, E; Kondo, H

    2017-04-01

    To provide target values for the manufacturers' survey of the Japanese Society for Laboratory Hematology (JSLH), accurate standard data from healthy volunteers were needed for the five-part differential leukocyte count. To obtain such data, JSLH required an antibody panel that achieved high specificity (particularly for mononuclear cells) using simple gating procedures. We developed a flow cytometric method for determining the differential leukocyte count (JSLH-Diff) and validated it by comparison with the flow cytometric differential leukocyte count of the International Council for Standardization in Haematology (ICSH-Diff) and the manual differential count obtained by microscopy (Manual-Diff). First, the reference laboratory performed an imprecision study of JSLH-Diff and ICSH-Diff, as well as performing comparison among JSLH-Diff, Manual-Diff, and ICSH-Diff. Then two reference laboratories and seven participating laboratories performed imprecision and accuracy studies of JSLH-Diff, Manual-Diff, and ICSH-Diff. Simultaneously, six manufacturers' laboratories provided their own representative values by using automated hematology analyzers. The precision of both JSLH-Diff and ICSH-Diff methods was adequate. Comparison by the reference laboratory showed that all correlation coefficients, slopes and intercepts obtained by the JSLH-Diff, ICSH-Diff, and Manual-Diff methods conformed to the criteria. When the imprecision and accuracy of JSLH-Diff were assessed at seven laboratories, the CV% for lymphocytes, neutrophils, monocytes, eosinophils, and basophils was 0.5~0.9%, 0.3~0.7%, 1.7~2.6%, 3.0~7.9%, and 3.8~10.4%, respectively. More than 99% of CD45 positive leukocytes were identified as normal leukocytes by JSLH-Diff. When JSLH-Diff method were validated by comparison with Manual-Diff and ICSH-Diff, JSLH-Diff showed good performance as a reference method. © 2016 John Wiley & Sons Ltd.

  11. Production of Landsat ETM+ reference imagery of burned areas within Southern African savannahs: comparison of methods and application to MODIS

    Science.gov (United States)

    A. M. S. Smith; N. A. Drake; M. J. Wooster; A. T. Hudak; Z. A. Holden; C. J. Gibbons

    2007-01-01

    Accurate production of regional burned area maps are necessary to reduce uncertainty in emission estimates from African savannah fires. Numerous methods have been developed that map burned and unburned surfaces. These methods are typically applied to coarse spatial resolution (1 km) data to produce regional estimates of the area burned, while higher spatial resolution...

  12. Development of a reference material for routine performance monitoring of methods measuring polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans and dioxin-like polychlorinated biphenyls.

    Science.gov (United States)

    Selliah, S S; Cussion, S; MacPherson, K A; Reiner, E J; Toner, D

    2001-06-01

    Matrix-matched environmental certified reference materials (CRMs) are one of the most useful tools to validate analytical methods, assess analytical laboratory performance and to assist in the resolution of data conflicts between laboratories. This paper describes the development of a lake sediment as a CRM for polychorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DLPCBs). The presence of DLPCBs in the environment is of increased concern and analytical methods are being developed internationally for monitoring DLPCBs in the environment. This paper also reports the results of an international interlaboratory study involving thirty-five laboratories from seventeen countries, conducted to characterize and validate levels of a sediment reference material for PCDDs, PCDFs and DLPCBs.

  13. EPA Office of Water (OW): STORET Water Quality Monitoring Stations NHDPlus Indexed Dataset

    Data.gov (United States)

    U.S. Environmental Protection Agency — Storage and Retrieval for Water Quality Data (STORET and the Water Quality Exchange, WQX) defines the methods and the data systems by which EPA compiles monitoring...

  14. EPA Science Matters Newsletter: Chemical Warfare Agent Analytical Standards Facilitate Lab Testing (Published November 2013)

    Science.gov (United States)

    Learn about the EPA chemists' efforts to develop methods for detecting extremely low concentrations of nerve agents, such as sarin, VX, soman and cyclohexyl sarin, and the blister agent sulfur mustard.

  15. EPA Office of Water (OW): STORET Water Quality Monitoring Stations Source Dataset

    Data.gov (United States)

    U.S. Environmental Protection Agency — Storage and Retrieval for Water Quality Data (STORET and the Water Quality Exchange, WQX) defines the methods and the data systems by which EPA compiles monitoring...

  16. Purchasing Supplies, Equipment and Services Under EPA Grants

    Science.gov (United States)

    EPA developed this guidance to help ensure you meet EPA requirements when making such necessary purchases. With very few exceptions, you must follow a competitive process when you use EPA grant funds to acquire equipment and professional services.

  17. Contribution of nuclear analysis methods to the certification of BCR reference materials for non-metals in non-ferrous metals

    International Nuclear Information System (INIS)

    Pauwels, J.

    1979-01-01

    A number of reference materials for oxygen in different non-ferrous metals have been certified by BCR in the frame of a multidisciplinary Community project. The contribution of nuclear analysis methods is illustrated by several examples concerning the optimization of sample preparation techniques, the analysis of low and high oxygen non-ferrous metals and the extension of the program to other non-metals, especially nitrogen and carbon. (author)

  18. Definition of the upper reference limit for thyroglobulin antibodies according to the National Academy of Clinical Biochemistry guidelines: comparison of eleven different automated methods

    OpenAIRE

    D?Aurizio, F.; Metus, P.; Ferrari, A.; Caruso, B.; Castello, R.; Villalta, D.; Steffan, A.; Gaspardo, K.; Pesente, F.; Bizzaro, N.; Tonutti, E.; Valverde, S.; Cosma, C.; Plebani, M.; Tozzoli, R.

    2017-01-01

    Purpose In the last two decades, thyroglobulin autoantibodies (TgAb) measurement has progressively switched from marker of thyroid autoimmunity to test associated with thyroglobulin (Tg) to verify the presence or absence of TgAb interference in the follow-up of patients with differentiated thyroid cancer. Of note, TgAb measurement is cumbersome: despite standardization against the International Reference Preparation MRC 65/93, several studies demonstrated high inter-method variability and wid...

  19. Preparation of the new certified reference material Virginia Tobacco Leaves (CTA-VTL-2) and development of suitable methods for checking the homogeneity

    International Nuclear Information System (INIS)

    Dybczynski, R.; Polkowska-Motrenko, H.; Samczynski, Z.; Szopa, Z.

    1994-01-01

    The aim of this project in the long run has been reparation of a new biological reference material: Tobacco leaves of the 'Virginia' type and its certification for the content of possibly great number of trace elements. Further aims have been: development of the suitable methods for checking the homogeneity with the special emphasis on homogeneity of small samples and the critical analysis of the performance of various analytical techniques

  20. Recent references

    International Nuclear Information System (INIS)

    Ramavataram, S.

    1991-01-01

    In support of a continuing program of systematic evaluation of nuclear structure data, the National Nuclear Data Center maintains a complete computer file of references to the nuclear physics literature. Each reference is tagged by a keyword string, which indicates the kinds of data contained in the article. This master file of Nuclear Structure References (NSR) contains complete keyword indexes to literature published since 1969, with partial indexing of older references. Any reader who finds errors in the keyword descriptions is urged to report them to the National Nuclear Data Center so that the master NSR file can be corrected. In 1966, the first collection of Recent References was published as a separate issue of Nuclear Data Sheets. Every four months since 1970, a similar indexed bibliography to new nuclear experiments has been prepared from additions to the NSR file and published. Beginning in 1978, Recent References was cumulated annually, with the third issue completely superseding the two issues previously published during a given year. Due to publication policy changes, cumulation of Recent Reference was discontinued in 1986. The volume and issue number of all the cumulative issues published to date are given. NNDC will continue to respond to individual requests for special bibliographies on nuclear physics topics, in addition to those easily obtained from Recent References. If the required information is available from the keyword string, a reference list can be prepared automatically from the computer files. This service can be provided on request, in exchange for the timely communication of new nuclear physics results (e.g., preprints). A current copy of the NSR file may also be obtained in a standard format on magnetic tape from NNDC. Requests for special searches of the NSR file may also be directed to the National Nuclear Data Center

  1. Calculations of non-adiabatic couplings within equation-of-motion coupled-cluster framework: Theory, implementation, and validation against multi-reference methods

    Science.gov (United States)

    Faraji, Shirin; Matsika, Spiridoula; Krylov, Anna I.

    2018-01-01

    We report an implementation of non-adiabatic coupling (NAC) forces within the equation-of-motion coupled-cluster with single and double excitations (EOM-CCSD) framework via the summed-state approach. Using illustrative examples, we compare NAC forces computed with EOM-CCSD and multi-reference (MR) wave functions (for selected cases, we also consider configuration interaction singles). In addition to the magnitude of the NAC vectors, we analyze their direction, which is important for the calculations of the rate of non-adiabatic transitions. Our benchmark set comprises three doublet radical-cations (hexatriene, cyclohexadiene, and uracil), neutral uracil, and sodium-doped ammonia clusters. When the characters of the states agree among different methods, we observe good agreement between the respective NAC vectors, both in the Franck-Condon region and away. In the cases of large discrepancies between the methods, the disagreement can be attributed to the difference in the states' character, which, in some cases, is very sensitive to electron correlation, both within single-reference and multi-reference frameworks. The numeric results confirm that the accuracy of NAC vectors depends critically on the quality of the underlying wave functions. Within their domain of applicability, EOM-CC methods provide a viable alternative to MR approaches.

  2. Evaluation of the PREVI® Isola automated seeder system compared to reference manual inoculation for antibiotic susceptibility testing by the disk diffusion method.

    Science.gov (United States)

    Le Page, S; van Belkum, A; Fulchiron, C; Huguet, R; Raoult, D; Rolain, J-M

    2015-09-01

    The disk diffusion (DD) method remains the most popular manual technique for antibiotic susceptibility testing (AST) in clinical microbiology laboratories. This is because of its simplicity, reproducibility, and limited cost compared to (automated) microdilution systems, which are usually less sensitive at detecting certain important mechanisms of resistance. Here, we evaluate the PREVI® Isola automated seeder system using a new protocol for spreading bacterial suspensions (eight deposits of calibrated inocula of bacteria, followed by two rounds of rotation) in comparison with manual DD reference testing on a large series of clinical and reference strains. The average time required for seeding one agar plate for DD with this new protocol was 51 s per plate, i.e., 70 agar plates/h. Reproducibility and repeatability was assessed on three reference and three randomly chosen clinical strains, as usually requested by the European Committee on Antimicrobial Susceptibility Testing (EUCAST), and was excellent compared to the manual method. The standard deviations of zones of growth inhibition showed no statistical discrimination. The correlation between the two methods, assessed using 294 clinical isolates and a panel of six antibiotics (n = 3,528 zones of growth inhibition measured), was excellent, with a correlation coefficient of 0.977. The new PREVI® Isola protocol adapted for DD had a sensitivity of 99 % and a specificity of 100 % compared to the manual technique for interpreting DD as recommended by the EUCAST.

  3. The calculation of dose from photon exposures using reference human phantoms and Monte Carlo methods. Pt. 5

    International Nuclear Information System (INIS)

    Petoussi, N.; Zankl, M.; Williams, G.; Veit, R.; Drexler, G.

    1987-01-01

    There has been some evidence that cervical cancer patients who were treated by radiotherapy, had an increased incidence of second primary cancers noticeable 15 years or more after the radiotherapy. The data suggested that high dose pelvic irradiation was associated with increase in cancers of the bladder, kidneys, rectum, ovaries, corpus uteri, and non-Hodgkin's lymphoma but not leukemia (Kleinerman et al., 1982, Morton 1973). The aim of the present work is to estimate the absorbed dose, due to radiotherapy treatment for cervival cancer, to various organs and tissues in the body. Monte Carlo calculations were performed to calculate the organ absorbed doses resulting from intracavitary sources such as ovoids and applicators filled or loaded with radium, Co-60 and Cs-137. For that purpose a routine which simulates an internal source was constructed and added to the existing Monte Carlo code (GSF-Bericht S-885, Kramer et al.). Calculations were also made for external beam therapy. Various anterior, posterior and lateral fields were applied, resulting from megavoltage, Co-60 and Cs-137 therapy machines. The calculated organ doses are tabulated in three different ways: as organ dose per air Kerma in the reference field, according to the recommendations of the International Commission on Radiation Units and Measurements (ICRU Report No 38, 1985); as organ dose per surface dose and as organ dose per tissue dose at Point B. (orig.)

  4. Evaluation of the k0 method by its application to (n, γ)RNaa of geological, environmental and clay reference materials

    International Nuclear Information System (INIS)

    Corte, F. de; Lin Xilei; Moens, L.; Wispelaere, A. de; Hoste, J.; Demeter, A.; Simonits, A.

    1984-01-01

    The k 0 standardization method, the state-of-the-art of which is shortly reviewed, has been applied to multi-element reactor neutron activation analysis of (standard) reference materials. The analyses have been performed independently at the Institute for Nuclear Sciences (Gent, Belgium) and the Central Research Institute for Physics (Budapest, Hungary). Results are given for USGS-2 (granite), NBS SRM-1633a (coal fly ash) and FCG (fired clay of Gent). Comparison with literature data shows that the k 0 method, while being experimentally simple, versatile and suited for computerization, offers a potential accuracy of better than 5%. (author)

  5. Why do women not return family history forms when referred to breast cancer genetics services? A mixed-method study.

    Science.gov (United States)

    Hanning, Kirstie A; Steel, Michael; Goudie, David; McLeish, Lorna; Dunlop, Jackie; Myring, Jessica; Sullivan, Frank; Berg, Jonathan; Humphris, Gerry; Ozakinci, Gozde

    2015-10-01

    Personal and family data forms, completed by women referred to breast cancer genetics clinics, are valuable tools for verification and extension of family history, crucial steps in accurate risk evaluation. A significant minority of women do not complete and return these forms, despite reminders, even when completion is a pre-requisite for a clinic appointment. To facilitate access of women at increased familial risk of breast cancer to screening and counselling services by investigating reasons for non-return of the forms. Based on a single regional 'breast cancer family' service in the UK, Analysis of quantitative data comparing women who did not return forms (n = 55) with those who had done so (n = 59), together with qualitative evaluation of potential barriers to form-completion through semi-structured telephone interviews with a random subset of 'non-returners' (n = 23). Non-returners have higher proportions of the very young (below the age at which surveillance could be offered) and of women from lower social deprivation categories. Interviews revealed that the majority of non-returners are anxious, rather than unconcerned about their breast cancer risk and circumstances and attitudes contributed to non-compliance. Twenty-one participants confirmed that they would welcome an appointment at a 'breast cancer family' clinic, but nine did not attend for the appointment. They were significantly younger than those who attend, but were not at lower familial risk. Many women who fail to complete and return a family history form would benefit from risk assessment and genetic counselling. Several steps are suggested that might help them access the relevant services. © 2014 John Wiley & Sons Ltd.

  6. A regional benthic fauna assessment method for the Southern North Sea using Margalef diversity and reference value modelling

    NARCIS (Netherlands)

    Loon, van Willem M.G.M.; Walvoort, Dennis J.J.; Hoey, van Gert; Vina-Herbon, Christina; Blandon, Abigayil; Pesch, Roland; Schmitt, Petra; Scholle, Jörg; Heyer, Karin; Lavaleye, Marc; Phillips, Graham; Duineveld, Gerard C.A.; Blomqvist, Mats

    2018-01-01

    The aims of this study are to develop an optimized method for regional benthic fauna assessment of the Southern North Sea which (a) is sensitive and precise (quantified as the slope and the R2 value of the pressure-impact relationships, respectively) for the anthropogenic pressures bottom fishing

  7. Purity Assessment of Organic Reference Materials with a Mass Balance Method: A Case Study of Endosulfan-II

    International Nuclear Information System (INIS)

    Kim, Seunghyun; Lee, Joonhee; Ahn, Seonghee; Song, Youngsin; Kim, Dongkyun; Kim, Byungjoo

    2013-01-01

    A mass balance method established in this laboratory was applied to determine the purity of an endosulfan-II pure substance. Gas chromatography-flame ionization detector (GC-FID) was used to measure organic impurities. Total of 10 structurally related organic impurities were detected by GC-FID in the material. Water content was determined to be 0.187% by Karl-Fischer (K-F) coulometry with an oven-drying method. Nonvolatile residual impurities was not detected by Thermal gravimetric analysis (TGA) within the detection limit of 0.04% (0.7 μg in absolute amount). Residual solvents within the substance were determined to be 0.007% in the Endosulfan-II pure substance by running GC-FID after dissolving it with two solvents. The purity of the endosulfan-II was finally assigned to be (99.17 ± 0.14)%. Details of the mass balance method including interpretation and evaluating uncertainties of results from each individual methods and the finally assayed purity were also described

  8. STANDARDIZATION OF GLYCOHEMOGLOBIN RESULTS AND REFERENCE VALUES IN WHOLE-BLOOD STUDIED IN 103 LABORATORIES USING 20 METHODS

    NARCIS (Netherlands)

    WEYKAMP, CW; PENDERS, TJ; MUSKIET, FAJ; VANDERSLIK, W

    We investigated the effect of calibration with lyophilized calibrators on whole-blood glycohemoglobin (glyHb) results. One hundred three laboratories, using 20 different methods, determined glyHb in two lyophilized calibrators and two whole-blood samples. For whole-blood samples with low (5%) and

  9. 40 CFR Appendix G to Part 50 - Reference Method for the Determination of Lead in Suspended Particulate Matter Collected From...

    Science.gov (United States)

    2010-07-01

    ... minimize the possibility of generating unreliable data, the user should follow practices established for... chapter—Modifications of methods by users. (Guidance or assistance in requesting approval under Section 2... lead content of the sample is analyzed by atomic absorption spectrometry using an air-acetylene flame...

  10. Evaluation of a new electronic preoperative reference marker for toric intraocular lens implantation by two different methods of analysis: Adobe Photoshop versus iTrace.

    Science.gov (United States)

    Farooqui, Javed Hussain; Sharma, Mansi; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2017-01-01

    The aim of this study is to compare two different methods of analysis of preoperative reference marking for toric intraocular lens (IOL) after marking with an electronic marker. Cataract and IOL Implantation Service, Shroff Eye Centre, New Delhi, India. Fifty-two eyes of thirty patients planned for toric IOL implantation were included in the study. All patients had preoperative marking performed with an electronic preoperative two-step toric IOL reference marker (ASICO AE-2929). Reference marks were placed at 3-and 9-o'clock positions. Marks were analyzed with two systems. First, slit-lamp photographs taken and analyzed using Adobe Photoshop (version 7.0). Second, Tracey iTrace Visual Function Analyzer (version 5.1.1) was used for capturing corneal topograph examination and position of marks noted. Amount of alignment error was calculated. Mean absolute rotation error was 2.38 ± 1.78° by Photoshop and 2.87 ± 2.03° by iTrace which was not statistically significant ( P = 0.215). Nearly 72.7% of eyes by Photoshop and 61.4% by iTrace had rotation error ≤3° ( P = 0.359); and 90.9% of eyes by Photoshop and 81.8% by iTrace had rotation error ≤5° ( P = 0.344). No significant difference in absolute amount of rotation between eyes when analyzed by either method. Difference in reference mark positions when analyzed by two systems suggests the presence of varying cyclotorsion at different points of time. Both analysis methods showed an approximately 3° of alignment error, which could contribute to 10% loss of astigmatic correction of toric IOL. This can be further compounded by intra-operative marking errors and final placement of IOL in the bag.

  11. EPA requirements for the uranium fuel cycle

    International Nuclear Information System (INIS)

    Dunster, H.J.

    1975-01-01

    The draft Environmental Statement issued by the Environmental Protection Agency (EPA) in the United States in preparation for Proposed Rulemaking Action concerning 'Environmental radiation protection requirements for normal operations of activities in the uranium fuel cycle' is summarized and discussed. The standards proposed by the EPA limit the annual dose equivalents to any member of the public, and also the releases of radionuclides to the 'general environment' for each gigawatt year of electrical energy produced. These standards were based on cost effectiveness arguements and levels and correspond to the ICRP recommendation to keep all exposures as low as reasonably achievable, economic and social factors being taken into account. They should be clearly distinguished from dose limits, although the EPA does not make this at all clear. The EPA seems to have shown an unexpected lack of understanding of the recommendations of ICRP Publication 9 (1965) and an apparent unawareness of ICRP Publication 22 (1973), and has therefore wrongly presented the new standards as a significant change in policy. The EPA has reviewed the information on the likely level of dose equivalents to members of the public and the likely cost reductions, thereby quantifying existing principles as applied to the fuel cycle as a whole. The EPA has stated that its proposals could be achieved as a cost in the region of Pound100,000 per death (or major genetic defect). It is pointed out that the EPA's use of the term 'waste' to exclude liquid and gaseous effluents may cause confusion. (U.K.)

  12. Stable isotope analyses of oxygen (18O:17O:16O) and chlorine (37Cl:35Cl) in perchlorate: reference materials, calibrations, methods, and interferences

    Science.gov (United States)

    Böhlke, John Karl; Mroczkowski, Stanley J.; Sturchio, Neil C.; Heraty, Linnea J.; Richman, Kent W.; Sullivan, Donald B.; Griffith, Kris N.; Gu, Baohua; Hatzinger, Paul B.

    2017-01-01

    RationalePerchlorate (ClO4−) is a common trace constituent of water, soils, and plants; it has both natural and synthetic sources and is subject to biodegradation. The stable isotope ratios of Cl and O provide three independent quantities for ClO4− source attribution and natural attenuation studies: δ37Cl, δ18O, and δ17O (or Δ17O or 17Δ) values. Documented reference materials, calibration schemes, methods, and interferences will improve the reliability of such studies.MethodsThree large batches of KClO4 with contrasting isotopic compositions were synthesized and analyzed against VSMOW-SLAP, atmospheric O2, and international nitrate and chloride reference materials. Three analytical methods were tested for O isotopes: conversion of ClO4− to CO for continuous-flow IRMS (CO-CFIRMS), decomposition to O2 for dual-inlet IRMS (O2-DIIRMS), and decomposition to O2 with molecular-sieve trap (O2-DIIRMS+T). For Cl isotopes, KCl produced by thermal decomposition of KClO4 was reprecipitated as AgCl and converted into CH3Cl for DIIRMS.ResultsKClO4 isotopic reference materials (USGS37, USGS38, USGS39) represent a wide range of Cl and O isotopic compositions, including non-mass-dependent O isotopic variation. Isotopic fractionation and exchange can affect O isotope analyses of ClO4− depending on the decomposition method. Routine analyses can be adjusted for such effects by normalization, using reference materials prepared and analyzed as samples. Analytical errors caused by SO42−, NO3−, ReO42−, and C-bearing contaminants include isotope mixing and fractionation effects on CO and O2, plus direct interference from CO2 in the mass spectrometer. The results highlight the importance of effective purification of ClO4− from environmental samples.ConclusionsKClO4 reference materials are available for testing methods and calibrating isotopic data for ClO4− and other substances with widely varying Cl or O isotopic compositions. Current ClO4−extraction, purification

  13. A comparative proteomics method for multiple samples based on a 18O-reference strategy and a quantitation and identification-decoupled strategy.

    Science.gov (United States)

    Wang, Hongbin; Zhang, Yongqian; Gui, Shuqi; Zhang, Yong; Lu, Fuping; Deng, Yulin

    2017-08-15

    Comparisons across large numbers of samples are frequently necessary in quantitative proteomics. Many quantitative methods used in proteomics are based on stable isotope labeling, but most of these are only useful for comparing two samples. For up to eight samples, the iTRAQ labeling technique can be used. For greater numbers of samples, the label-free method has been used, but this method was criticized for low reproducibility and accuracy. An ingenious strategy has been introduced, comparing each sample against a 18 O-labeled reference sample that was created by pooling equal amounts of all samples. However, it is necessary to use proportion-known protein mixtures to investigate and evaluate this new strategy. Another problem for comparative proteomics of multiple samples is the poor coincidence and reproducibility in protein identification results across samples. In present study, a method combining 18 O-reference strategy and a quantitation and identification-decoupled strategy was investigated with proportion-known protein mixtures. The results obviously demonstrated that the 18 O-reference strategy had greater accuracy and reliability than other previously used comparison methods based on transferring comparison or label-free strategies. By the decoupling strategy, the quantification data acquired by LC-MS and the identification data acquired by LC-MS/MS are matched and correlated to identify differential expressed proteins, according to retention time and accurate mass. This strategy made protein identification possible for all samples using a single pooled sample, and therefore gave a good reproducibility in protein identification across multiple samples, and allowed for optimizing peptide identification separately so as to identify more proteins. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. The evaluation of accuracy of NAA method used by P2TRR laboratory with food standard reference material analysis

    International Nuclear Information System (INIS)

    Rina M, Th.; Sri-Wardhani; Sunarko

    2003-01-01

    The NAA method is the analysis method with high precision and accuracy level. The precision and accuracy of NAA laboratory in P2TRR had been evaluated with SRM 1573a Tomato Leaf and CRM No.9 Sargasso. Samples were irradiated in RSG-GAS's rabbit system and counted with gamma spectrometry. The results obtained from this research are for the SRM 1573a sample the test could analyze 17 elements of the 40 certified elements, and for CRM No.9 sample the test could analyze 16 elements of the 30 certified elements. The result of quantitative analysis indicate the different deviation of each element between 2 -10.5 % compared to the certificate data. This deviation value <15%, this value shows that the precision and accuracy level is good enough

  15. High-grade cervical lesions among women attending a reference clinic in Brazil: associated factors and comparison among screening methods.

    Directory of Open Access Journals (Sweden)

    Neide T Boldrini

    Full Text Available Although screening for cervical cancer is recommended for women in most countries, the incidence of cervical cancer is greater in developing countries. Our goal was to determine the prevalence and factors associated with high-grade lesions/cervical cancer among women attending a reference clinic in Brazil and evaluate the correlation of histology with cytology, colposcopy and the high-risk HPV (HR-HPV tests.A cross-sectional study of women attending a colposcopy clinic was carried out. The patients were interviewed to collect demographic, epidemiological and clinical data. Specimens were collected for cervical cytology, Chlamydia trachomatis and HPV testing using the Hybrid Capture (HC and PCR tests. Colposcopy was performed for all patients and biopsy for histology when cell abnormalities or cervical intraepithelial neoplasia (CIN were present.A total of 291 women participated in the study. The median age was 38 years (DIQ: 30-48 years. The prevalence of histologically confirmed high-grade lesions/cervical cancer was 18.2% (95%, CI: 13.8%-22.6%, with 48 (16.5% cases of CIN-2/CIN-3 and 5 (1.7% cases of invasive carcinoma. In the final logistic regression model, for ages between 30 and 49 years old [OR = 4.4 (95%: 1.01-19.04, history of smoking [OR = 2.4 (95%, CI: 1.14-5.18], practice of anal intercourse [OR = 2.4 (95%, CI: 1.10-5.03] and having positive HC test for HR-HPV [OR = 11.23 (95%, CI: 4 0.79-26, 36] remained independently associated with high-grade lesions/cervical cancer. A total of 64.7% of the cases CIN-3\\Ca in situ were related to HPV-16. Non-oncogenic HPV were only found in CIN-1 biopsy results. Compared to histology, the sensitivity of cytology was 31.8%, the specificity 95.5%; the sensitivity of colposcopy for high-grade lesions/cervical cancer was 51.0%, specificity was 91.4% and the concordance with HPV testing was high.The results confirm an association of HR-HPV with precursor lesions for cervical cancer

  16. Evaluation of RNA extraction methods and identification of putative reference genes for real-time quantitative polymerase chain reaction expression studies on olive (Olea europaea L.) fruits.

    Science.gov (United States)

    Nonis, Alberto; Vezzaro, Alice; Ruperti, Benedetto

    2012-07-11

    Genome wide transcriptomic surveys together with targeted molecular studies are uncovering an ever increasing number of differentially expressed genes in relation to agriculturally relevant processes in olive (Olea europaea L). These data need to be supported by quantitative approaches enabling the precise estimation of transcript abundance. qPCR being the most widely adopted technique for mRNA quantification, preliminary work needs to be done to set up robust methods for extraction of fully functional RNA and for the identification of the best reference genes to obtain reliable quantification of transcripts. In this work, we have assessed different methods for their suitability for RNA extraction from olive fruits and leaves and we have evaluated thirteen potential candidate reference genes on 21 RNA samples belonging to fruit developmental/ripening series and to leaves subjected to wounding. By using two different algorithms, GAPDH2 and PP2A1 were identified as the best reference genes for olive fruit development and ripening, and their effectiveness for normalization of expression of two ripening marker genes was demonstrated.

  17. Quantification of pneumothorax volume on chest radiographs: comparison between the collins' and the axel's methods with three-dimensional CT as the standard of reference

    International Nuclear Information System (INIS)

    Lee, Chang Keun; Kim, Hyung Jin; Lee, Kyung Hee; Kim, Joung Taek; Kim, Kwang Ho; Suh, Chang Hae; Han, Heon

    1999-01-01

    The purpose of this study was twofold. In a preliminary study, we evaluated the accuracy of 3-D (three-dimensional) CT for the estimation of pneumothorax volume and for providing the optimal postprocessing method for clinical study. In the clinical study, we determined which of the two methods, Collins' and Axel's, was more accurate for the estimation of pneumothorax volume, as seen on chest radiographs, using 3-D CT as the standard of reference. In the preliminary study, 3-D CT was applied to phantoms and to four patients with pneumothorax using two different postprocessing methods, manual contour delineation and thresholding. In the clinical study, 3-D CT was performed in 13 patients with pneumothorax. For the purpose of evaluating conventional radiographs, a localizer scan was used for comparing the accuracy of Collins' method with that of Axel's method, with 3-D CT as the standard of reference. The preliminary study revealed that 3-D CT estimated pneumothorax volume with great accuracy and that manual contour delineation and thresholding measured volume equally well. Because of the shorter postprocessing time required with thresholding than with manual contour delineation (5 min versus 30 min), the former was used during clinical study. The results of this indicated close correlation between the measurements obtained using Collins' method on chest radiographs and those obtained by 3-D CT(r=0.95, p 0.05). 3-D CT can estimate pneumothorax volume with great accuracy. Collins' method is superior to Axel's method for the quantification of pneumothorax volume as seen on chest radiographs

  18. International comparison of the economy of constructing nuclear power plants by using the method of referred investment costs in Czechoslovakia and in the USA

    International Nuclear Information System (INIS)

    Majer, P.; Jelen, J.

    1989-01-01

    The method of referred investment costs was applied to a comparison of the economy of constructing the nuclear power plant at Temelin, Czechoslovakia, with that for the hypothetic nuclear power plant at Middletown, USA. For a reasonably adopted Czechoslovak crown/USD rate, the obtained costs for building the Temelin power plant are 50% higher than those for building the reference Middletown power plant. This compares rather favorably with the general level of investment costs in Czechoslovakia under the present economic conditions. The analysis performed shows that savings in investment costs should be sought in the fields of technological modernization of preparatory work and in all construction work, with the aim to reduce particularly live work. (P.A.). 12 tabs., 8 refs

  19. Monitor Clean and Efficient. Background information. Methods and references as applied in the Monitor in April 2009

    International Nuclear Information System (INIS)

    Gerdes, J.; De Ligt, T.

    2010-01-01

    This report contains background information about the Monitor Clean and Efficient that was published in April 2009. The goal and approach of the Monitor are clarified, as well as the methods and data that are used. The structure of this report resembles the structure of the Monitor. Sources and dates of availability are mentioned along with the data, as are the parties collecting and processing the information. The results that were found using this methodology have been published in the Monitor Clean and Efficient. [nl

  20. A simple method for optimising transformation of non-parametric data: an illustration by reference to cortisol assays.

    Science.gov (United States)

    Clark, James E; Osborne, Jason W; Gallagher, Peter; Watson, Stuart

    2016-07-01

    Neuroendocrine data are typically positively skewed and rarely conform to the expectations of a Gaussian distribution. This can be a problem when attempting to analyse results within the framework of the general linear model, which relies on assumptions that residuals in the data are normally distributed. One frequently used method for handling violations of this assumption is to transform variables to bring residuals into closer alignment with assumptions (as residuals are not directly manipulated). This is often attempted through ad hoc traditional transformations such as square root, log and inverse. However, Box and Cox (Box & Cox, ) observed that these are all special cases of power transformations and proposed a more flexible method of transformation for researchers to optimise alignment with assumptions. The goal of this paper is to demonstrate the benefits of the infinitely flexible Box-Cox transformation on neuroendocrine data using syntax in spss. When applied to positively skewed data typical of neuroendocrine data, the majority (~2/3) of cases were brought into strict alignment with Gaussian distribution (i.e. a non-significant Shapiro-Wilks test). Those unable to meet this challenge showed substantial improvement in distributional properties. The biggest challenge was distributions with a high ratio of kurtosis to skewness. We discuss how these cases might be handled, and we highlight some of the broader issues associated with transformation. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  1. Comprehensive profiling of retroviral integration sites using target enrichment methods from historical koala samples without an assembled reference genome

    Directory of Open Access Journals (Sweden)

    Pin Cui

    2016-03-01

    Full Text Available Background. Retroviral integration into the host germline results in permanent viral colonization of vertebrate genomes. The koala retrovirus (KoRV is currently invading the germline of the koala (Phascolarctos cinereus and provides a unique opportunity for studying retroviral endogenization. Previous analysis of KoRV integration patterns in modern koalas demonstrate that they share integration sites primarily if they are related, indicating that the process is currently driven by vertical transmission rather than infection. However, due to methodological challenges, KoRV integrations have not been comprehensively characterized. Results. To overcome these challenges, we applied and compared three target enrichment techniques coupled with next generation sequencing (NGS and a newly customized sequence-clustering based computational pipeline to determine the integration sites for 10 museum Queensland and New South Wales (NSW koala samples collected between the 1870s and late 1980s. A secondary aim of this study sought to identify common integration sites across modern and historical specimens by comparing our dataset to previously published studies. Several million sequences were processed, and the KoRV integration sites in each koala were characterized. Conclusions. Although the three enrichment methods each exhibited bias in integration site retrieval, a combination of two methods, Primer Extension Capture and hybridization capture is recommended for future studies on historical samples. Moreover, identification of integration sites shows that the proportion of integration sites shared between any two koalas is quite small.

  2. Use of fat mass and fat free mass standard deviation scores obtained using simple measurement methods in healthy children and patients: comparison with the reference 4-component model.

    Science.gov (United States)

    Atherton, Rachel R; Williams, Jane E; Wells, Jonathan C K; Fewtrell, Mary S

    2013-01-01

    Clinical application of body composition (BC) measurements for individual children has been limited by lack of appropriate reference data. (1) To compare fat mass (FM) and fat free mass (FFM) standard deviation scores (SDS) generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C) model; (2) To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy), BMI and skinfold thicknesses (SFT); and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height(2)/Z)) in 927 subjects aged 3.8-22.0 y (211 healthy, 716 patients). DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement) FM SDS 0.03 (± 0.62); FFM SDS -0.04 (± 0.72)), and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤-2 or ≥ 2). BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome.

  3. Use of fat mass and fat free mass standard deviation scores obtained using simple measurement methods in healthy children and patients: comparison with the reference 4-component model.

    Directory of Open Access Journals (Sweden)

    Rachel R Atherton

    Full Text Available BACKGROUND: Clinical application of body composition (BC measurements for individual children has been limited by lack of appropriate reference data. OBJECTIVES: (1 To compare fat mass (FM and fat free mass (FFM standard deviation scores (SDS generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C model; (2 To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. DESIGN: FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy, BMI and skinfold thicknesses (SFT; and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height(2/Z in 927 subjects aged 3.8-22.0 y (211 healthy, 716 patients. RESULTS: DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement FM SDS 0.03 (± 0.62; FFM SDS -0.04 (± 0.72, and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤-2 or ≥ 2. BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. CONCLUSIONS: DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome.

  4. HUBUNGAN KECUKUPAN ASAM EIKOSAPENTANOAT (EPA, ASAM DOKOSAHEKSANOAT (DHA IKAN DAN STATUS GIZI DENGAN PRESTASI BELAJAR SISWA

    Directory of Open Access Journals (Sweden)

    Siti Zulaihah

    2012-04-01

    Full Text Available ABSTRACT   Background: Fish contain of high protein, EPA, DHA needed for the formation of brain cell and improving intelligence. Consuming fish and other sea food make healthy and improve the brain ability to reach optimum study achievement. In 2003, fish consumption in Indonesia is still low 24,67kg/capita/year. Based on BPS 2002, fish consumption in Semarang is 5,38%. The fish consumption has a big influence on nutrition sufficiency especially EPA and DHA, nutrition status and attaining healthy and smart Indonesian human resources. Goal: To analyze the relationship between fish meal frequency, fish EPA and DHA recommended and nutrition status with student's study achievement. Method: The research used survey method, analytical research, and cross -sectional time approach. This research was conducted on September-October 2004. Sample was 100 subject of SD Taqwiyatui Wathon (grade IV are 54 person, grade V are 46 person by using Stratified Random Sampling method. The data preparation used NUTRISOFT. Result: Fish frequently consumed by responden was bandeng (Chanos chanos 5%, tongkol (Euthynnus allitteratus rafmescue 4%, kembung (Scomber kanoguria russei 1% and mujair (Tilapia mossambica 1 %. EPA, DHA % RDA defisit 62%, normal nutritional status 93% and average category of study achievement 55%. There was relation between fish meal frequency and fish EPA, DHA % RDA (ρ=0,000, there was no relation between fish meal frequency and nutritional status (ρ=0,213, there was relation between fish meal frequency and study achievement (ρ=0,000, there was relation between fish EPA, DHA recommendation and study achievement (ρ=0,000, and there was no relation between nutrition status and study achievement (ρ=0.378. Based on Pearson correlation test, there was no relation between fish EPA, DHA recommendation and nutritional status (ρ=0,000. Conclution: Students with frequent fish consumption and high RDA of EPA, DHA % RDA showed better study achievement

  5. Use of stable isotopes method in hydrological investigations with special reference to studies in Lower Maner Basin, Andhra Pradesh

    International Nuclear Information System (INIS)

    Kumar, B.; Athavale, R.N.; Sahay, K.S.N.

    1982-01-01

    The study of variations of stable isotope ratios in water is becoming increasingly important in hydrological investigations and is being widely used for: (i) characterizing water masses and indicating their origin, (ii) finding interconnection of water bodies, (iii) estimating leakages for reservoirs, (iv) water balances studies of lakes, (v) glaciological studies, etc. This paper briefly describes the principle of the method and details of isotope ratio measurement techniques used at the National Geophysical Research Institute, Hyderabad. Integrated geohydrological investigations comprising photogeological, hydrogeochemical, geophysical, nuclear and modelling studies have been carried out in the Lower Maner Basin, A.P., under an Indo-German collaboration project. As a part of this programme,, precipitation, surface and sub-surface water samples from the basin were analysed for their D:H and O 18 :O 16 ratios. The results of these measurements are presented and discussed. (author)

  6. Environmental Protection Agency - EPA Pub Central

    Data.gov (United States)

    U.S. Environmental Protection Agency — PubMed Central (PMC) is a full-text, online archive of journal literature operated by the National Library of Medicine. The EPA is using PMC to permanently preserve...

  7. EPA Facility Registry Service (FRS): RADINFO

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  8. EPA CIO Governance Board Membership List

    Science.gov (United States)

    In keeping with OMB guidance on implementing the Federal Information Technology Reform Act (FITARA), EPA is publishing its list of officials who perform the duties or responsibilities of a Bureau CIO.

  9. Level IV Ecoregions of EPA Region 1

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  10. Level III Ecoregions of EPA Region 1

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  11. EPA Linked Open Data: Toxics Release Inventory

    Data.gov (United States)

    U.S. Environmental Protection Agency — TRI is a publicly available EPA database reported annually by certain covered industry groups, as well as federal facilities. It contains information about more than...

  12. Concerns raised over new EPA members

    Science.gov (United States)

    Gwynne, Peter

    2017-12-01

    The Trump administration has nominated three new members of the Environmental Protection Agency (EPA) who critics say are undermining laws and “pampering” the industries they are supposed to regulate.

  13. Meet EPA Researcher Endalkachew Sahle-Demessie

    Science.gov (United States)

    Meet EPA Researcher Endalkachew Sahle-Demessie. Chemical and Environmental Engineer Endalkachew Sahle-Demessie, Ph.D., works on various projects, including nanomaterials and water resources, in EPA’s National Risk Management Research Laboratory.

  14. EPA Administrative Law Judge Legal Documents

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains Decisions and Orders originating from EPAs Office of Administrative Law Judges (OALJ), which is an independent office in the Office of the...

  15. EPA Facility Registry Service (FRS): NEI

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  16. EPA RE-Powering Mapper Feasibility Studies

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  17. EPA Facility Registry Service (FRS): BIA

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  18. EPA RE-Powering Mapper Region 7

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  19. EPA RE-Powering Mapper Large Scale

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  20. EPA RE-Powering Mapper Region 6

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  1. EPA RE-Powering Mapper Region 8

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  2. EPA RE-Powering Mapper Region 5

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  3. EPA RE-Powering Mapper Region 3

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  4. EPA Facility Registry Service (FRS): BRAC

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  5. EPA Region 6 REAP Composite Geodatabse

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Regional Ecological Assessment Protocol (REAP) is a screening level tool created as a way to identify priority ecological resources within the five EPA Region 6...

  6. EPA Facility Registry Service (FRS): NCDB

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  7. EPA Center for Corporate Climate Leadership

    Science.gov (United States)

    EPA's Center for Corporate Climate Leadership is a comprehensive resource to help organizations measure & manage GHG emissions. The Center provides technical tools, educational resources, opportunities for information sharing & highlights best practices.

  8. Level IV Ecoregions of EPA Region 5

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  9. Level IV Ecoregions of EPA Region 10

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  10. Level IV Ecoregions of EPA Region 2

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  11. Level IV Ecoregions of EPA Region 3

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  12. Level III Ecoregions of EPA Region 2

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  13. Level III Ecoregions of EPA Region 4

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  14. Level III Ecoregions of EPA Region 8

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions for EPA Administrative Regions were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the...

  15. Level IV Ecoregions of EPA Region 7

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  16. Level IV Ecoregions of EPA Region 6

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  17. Substance Identification Information from EPA's Substance Registry

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Substance Registry Services (SRS) is the authoritative resource for basic information about substances of interest to the U.S. EPA and its state and tribal...

  18. Springs, US EPA Region 9, 2013, SDWIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPAâ??s Safe Drinking Water Information System (SDWIS) databases store information about drinking water. The federal version (SDWIS/FED) stores the information EPA...

  19. Reservoirs, US EPA Region 9, 2013, SDWIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPAâ??s Safe Drinking Water Information System (SDWIS) databases store information about drinking water. The federal version (SDWIS/FED) stores the information EPA...

  20. EPA Monthly Key Performance Indicator Dashboards 2018

    Science.gov (United States)

    2018 reports are added each month, which measure how well EPA web content is meeting three performance goals: increases in how much users consume content, are able to find or discover what they need, and their level of engagement.

  1. EPA RE-Powering Screening Shapefile

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Center for Program Analysis (CPA) initiated the RE-Powering America’s...

  2. EPA Region 1 Sole Source Aquifers

    Data.gov (United States)

    U.S. Environmental Protection Agency — This coverage contains boundaries of EPA-approved sole source aquifers. Sole source aquifers are defined as an aquifer designated as the sole or principal source of...

  3. Checklist for Reviewing EPA Quality Management Plans

    Science.gov (United States)

    This checklist will be used to review the Quality Management Plans (QMPs) that are submitted to the Quality Staff of the Office of Environmental Information (OEI) for Agency review under EPA Order 5360.1 A2.

  4. Quality Management Plan for EPA Region 1

    Science.gov (United States)

    The QMP describes policies, procedures & management systems within EPA NE that govern quality assurance & quality control activities supporting the transparency & scientific defensibility of environmental data collected, used & disseminated by the Region.

  5. EPA Facility Registry Service (FRS): Power Plants

    Data.gov (United States)

    U.S. Environmental Protection Agency — This GIS dataset contains data on power plants, based on the Energy Information Administration's EIA-860 dataset and supplemented with data from EPA's Facility...

  6. EPA Communications Stylebook: Training and Education

    Science.gov (United States)

    It is the policy of EPA that our staff should have and develop good communications skills. Besides writing, style, and design skills, we seek to develop audience analysis and targeting, marketing and media selection, and computer skills.

  7. EPA Linked Open Data: Facility Registry Service

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Facility Registry Service (FRS) identifies facilities, sites, or places subject to environmental regulation or of environmental interest to EPA programs or...

  8. Level IV Ecoregions of EPA Region 8

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions for EPA Administrative Regions were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the...

  9. Level III Ecoregions of EPA Region 10

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  10. Level IV Ecoregions of EPA Region 4

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  11. Level IV Ecoregions of EPA Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions for EPA Administrative Regions were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the...

  12. Level III Ecoregions of EPA Region 3

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  13. Level III Ecoregions of EPA Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions for EPA Administrative Regions were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the...

  14. 2013 EPA Vessels General Permit (VGP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Information for any vessel that submitted a Notice of Intent (NOI), Notice of Termination (NOT), or annual report under EPA's 2013 Vessel General Permit (VGP)....

  15. EPA Region 6 REAP Diversity Geodatabase

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Regional Ecological Assessment Protocol (REAP) is a screening level tool created as a way to identify priority ecological resources within the five EPA Region 6...

  16. EPA Facility Registry Service (FRS): TRI

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  17. EPA Facility Registry Service (FRS): ICIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  18. EPA Facility Registry Service (FRS): OIL

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Oil...

  19. EPA Facility Registry Service (FRS): RBLC

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  20. EPA Facility Registry Service (FRS): ACRES

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service consists of location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of sites that link to...

  1. EPA Facility Registry System (FRS): NCES

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  2. EPA Facility Registry Service (FRS): LANDFILL

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of non-hazardous waste...

  3. EPA Facility Registry Service (FRS): CAMDBS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  4. Level III Ecoregions of EPA Region 7

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  5. EPA perspective on radionuclide aerosol sampling

    Energy Technology Data Exchange (ETDEWEB)

    Karhnak, J.M. [Environmental Protection Agency, Washington, DC (United States)

    1995-02-01

    The Environmental Protection Agency (EPA) is concerned with radionuclide aerosol sampling primarily at Department of Energy (DOE) facilities in order to insure compliance with national air emission standards, known as NESHAPs. Sampling procedures are specified in {open_quotes}National Emission Standards for Emissions of Radionuclides other than Radon from Department of Energy Sites{close_quotes} (Subpart H). Subpart H also allows alternate procedures to be used if they meet certain requirements. This paper discusses some of the mission differences between EPA and Doe and how these differences are reflected in decisions that are made. It then describes how the EPA develops standards, considers alternate sampling procedures, and lists suggestions to speed up the review and acceptance process for alternate procedures. The paper concludes with a discussion of the process for delegation of Radionuclide NESHAPs responsibilities to the States, and responsibilities that could be retained by EPA.

  6. Level III Ecoregions of EPA Region 5

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  7. VT US EPA Regulated Facilities Point Locations

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The EnvironPollution_ENVPTS2001 data layer is based on the U.S. EPA's Envirofacts point shapefile. The data was provided to VCGI by the Vermont...

  8. EPA RE-Powering Mapper Completed Installations

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  9. Methane Tracking and Mitigation Options - EPA CMOP

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains the sub-model for EPA's MARKAL model, which tracks methane emissions from the energy system, and limited other sources (landfills and manure...

  10. EPA RE-Powering Mapper Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  11. EPA RE-Powering Mapper Region 10

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  12. EPA Facility Registry System (FRS): NEPT

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  13. EPA RE-Powering Mapper Region 4

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  14. EPA Facility Registry Service (FRS): SDWIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  15. EPA RE-Powering Mapper Utility Scale

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  16. EPA RE-Powering Mapper Region 2

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  17. EPA RE-Powering Mapper Region 1

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  18. EPA Linked Open Data: Chemical Data Reporting

    Data.gov (United States)

    U.S. Environmental Protection Agency — This resource consists of the Chemical Data Reporting database that supports the Toxic Substances Control Act (TSCA) of 1976, which provides EPA with authority to...

  19. Level III Ecoregions of EPA Region 6

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  20. Registry of EPA Applications, Models, and Databases

    Data.gov (United States)

    U.S. Environmental Protection Agency — READ is EPA's authoritative source for information about Agency information resources, including applications/systems, datasets and models. READ is one component of...

  1. EPA Facility Registry Service (FRS): RCRA

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of hazardous waste...

  2. EPA Facility Registry Service (FRS): RMP

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  3. EPA Region 1 Environmentally Sensitive Areas

    Science.gov (United States)

    This coverage represents polygon equivalents of environmentally sensitive areas (ESA) in EPA Region I. ESAs were developed as part of an EPA headquarters initiative based on reviews of various regulatory and guidance documents, as well as phone interviews with federal/state/local government agencies and private organizations. ESAs include, but are not limited to, wetlands, biological resources, habitats, national parks, archaeological/historic sites, natural heritage areas, tribal lands, drinking water intakes, marinas/boat ramps, wildlife areas, etc.

  4. The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Pt. 6

    International Nuclear Information System (INIS)

    Zankl, M.; Panzer, W.; Drexler, G.

    1991-11-01

    Computed tomography (CT) is a technique which offers a high diagnostic capability; however, the dose to the patient is high compared to conventional radiography. This report provides a catalogue of organ doses resulting from CT examinations. The organ doses were calculated for the type of CT scanners most commonly used in the FRG and for three different radiation qualities. For the dose calculations, the patients were represented by the adult mathematical phantoms Adam and Eva. The radiation transport in the body was simulated using a Monte Carlo method. The doses were calculated as conversion factors of mean organ doses per air kerma free in air on the axis of rotation. Mean organ dose conversion factors are given per organ and per single CT slice of 1 cm width. The mean dose to an organ resulting from a particular CT examination can be estimated by summing up the contribution to the organ dose from each relevant slice. In order to facilitate the selection of the appropriate slices, a table is given which relates the mathematical phantoms' coordinates to certain anatomical landmarks in the human body. (orig.)

  5. Implementation of the multireference Brillouin-Wigner and Mukherjee’s coupled cluster methods with non-iterative triple excitations utilizing reference-level parallelism

    Energy Technology Data Exchange (ETDEWEB)

    Bhaskaran-Nair, Kiran; Brabec, Jiri; Apra, Edoardo; van Dam, Hubertus JJ; Pittner, Jiri; Kowalski, Karol

    2012-09-07

    In this paper we discuss the performance of the non-iterative State-Specific Mul- tireference Coupled Cluster (SS-MRCC) methods accounting for the effect of triply excited cluster amplitudes. The corrections to the Brillouin-Wigner and Mukherjee MRCC models based on the manifold of singly and doubly excited cluster amplitudes (BW-MRCCSD and Mk-MRCCSD, respectively) are tested and compared with the exact full configuration interaction results (FCI) for small systems (H2O, N2, and Be3). For larger systems (naphthyne isomers and -carotene), the non-iterative BW-MRCCSD(T) and Mk-MRCCSD(T) methods are compared against the results obtained with the single reference coupled cluster methods. We also report on the parallel performance of the non-iterative implementations based on the use of pro- cessor groups.

  6. Plan for implementing EPA standards for UMTRA sites

    International Nuclear Information System (INIS)

    1984-01-01

    The Uranium Mill Tailings Radiation Control Act of 1978 (UMTRCA), authorizes the Department of Energy (DOE) to undertake remedial actions at 24 DOE designated processing sites. The term ''processing site,'' by statutory definition, means the inactive uranium mill or processing site and any other real property or improvement which is in the vicinity of the mill or processing site and is determined to be contaminated with residual radioactive materials derived from the mill or processing site. For purposes of this document, the inactive mill or processing site is referred to as the ''processing site'' and the other real property or improvement in the vicinity of such site is referred to as a 'vicinity property.'' The purpose of the remedial actions is to stabilize and control the uranium mill tailings and other residual radioactive materials in a safe and environmentally sound manner. Remedial actions undertaken by DOE are to be accomplished: With the full participation of the affected states and Indian tribes, in accordance with standards issued by the Environmental Protection Agency (EPA), and with the concurrence of the Nuclear Regulatory Commission (NRC). This plan is designed to be a generic presentation on methodology that will be followed in implementing the EPA standards. 5 refs., 1 tab

  7. Evaluating new HbA1c methods for adoption by the IFCC and NGSP reference networks using international quality targets.

    Science.gov (United States)

    Lenters-Westra, Erna; English, Emma

    2017-08-28

    As a reference laboratory for HbA1c, it is essential to have accurate and precise HbA1c methods covering a range of measurement principles. We report an evaluation of the Abbott Enzymatic (Architect c4000), Roche Gen.3 HbA1c (Cobas c513) and Tosoh G11 using different quality targets. The effect of hemoglobin variants, other potential interferences and the performance in comparison to both the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the National Glycohemoglobin Standardization Program (NGSP) reference systems was assessed using certified evaluation protocols. Each of the evaluated HbA1c methods had CVs HbA1c. Partly based on the result of this study, the Abbott Enzymatic method on the Architect c4000 and the Roche Gen.3 HbA1c on the Cobas c513 are now official, certified IFCC and NGSP SRMPs in the IFCC and NGSP networks. Sigma metrics quality criteria presented in a graph distinguish between good and excellent performance.

  8. Development of real-time PCR method for the detection and the quantification of a new endogenous reference gene in sugar beet "Beta vulgaris L.": GMO application.

    Science.gov (United States)

    Chaouachi, Maher; Alaya, Akram; Ali, Imen Ben Haj; Hafsa, Ahmed Ben; Nabi, Nesrine; Bérard, Aurélie; Romaniuk, Marcel; Skhiri, Fethia; Saïd, Khaled

    2013-01-01

    KEY MESSAGE : Here, we describe a new developed quantitative real-time PCR method for the detection and quantification of a new specific endogenous reference gene used in GMO analysis. The key requirement of this study was the identification of a new reference gene used for the differentiation of the four genomic sections of the sugar beet (Beta vulgaris L.) (Beta, Corrollinae, Nanae and Procumbentes) suitable for quantification of genetically modified sugar beet. A specific qualitative polymerase chain reaction (PCR) assay was designed to detect the sugar beet amplifying a region of the adenylate transporter (ant) gene only from the species of the genomic section I of the genus Beta (cultivated and wild relatives) and showing negative PCR results for 7 species of the 3 other sections, 8 related species and 20 non-sugar beet plants. The sensitivity of the assay was 15 haploid genome copies (HGC). A quantitative real-time polymerase chain reaction (QRT-PCR) assay was also performed, having high linearity (R (2) > 0.994) over sugar beet standard concentrations ranging from 20,000 to 10 HGC of the sugar beet DNA per PCR. The QRT-PCR assay described in this study was specific and more sensitive for sugar beet quantification compared to the validated test previously reported in the European Reference Laboratory. This assay is suitable for GMO quantification in routine analysis from a wide variety of matrices.

  9. A Reference-Free and Non-Contact Method for Detecting and Imaging Damage in Adhesive-Bonded Structures Using Air-Coupled Ultrasonic Transducers

    Directory of Open Access Journals (Sweden)

    Timotius Yonathan Sunarsa

    2017-12-01

    Full Text Available Adhesive bonded structures have been widely used in aerospace, automobile, and marine industries. Due to the complex nature of the failure mechanisms of bonded structures, cost-effective and reliable damage detection is crucial for these industries. Most of the common damage detection methods are not adequately sensitive to the presence of weakened bonding. This paper presents an experimental and analytical method for the in-situ detection of damage in adhesive-bonded structures. The method is fully non-contact, using air-coupled ultrasonic transducers (ACT for ultrasonic wave generation and sensing. The uniqueness of the proposed method relies on accurate detection and localization of weakened bonding in complex adhesive bonded structures. The specimens tested in this study are parts of real-world structures with critical and complex damage types, provided by Hyundai Heavy Industries® and IKTS Fraunhofer®. Various transmitter and receiver configurations, including through transmission, pitch-catch scanning, and probe holder angles, were attempted, and the obtained results were analyzed. The method examines the time-of-flight of the ultrasonic waves over a target inspection area, and the spatial variation of the time-of-flight information was examined to visualize and locate damage. The proposed method works without relying on reference data obtained from the pristine condition of the target specimen. Aluminum bonded plates and triplex adhesive layers with debonding and weakened bonding were used to examine the effectiveness of the method.

  10. Different percentages of false-positive results obtained using five methods for the calculation of reference change values based on simulated normal and ln-normal distributions of data

    DEFF Research Database (Denmark)

    Lund, Flemming; Petersen, Per Hyltoft; Fraser, Callum G

    2016-01-01

    a homeostatic set point that follows a normal (Gaussian) distribution. This set point (or baseline in steady-state) should be estimated from a set of previous samples, but, in practice, decisions based on reference change value are often based on only two consecutive results. The original reference change value......-positive results. The aim of this study was to investigate false-positive results using five different published methods for calculation of reference change value. METHODS: The five reference change value methods were examined using normally and ln-normally distributed simulated data. RESULTS: One method performed...... best in approaching the theoretical false-positive percentages on normally distributed data and another method performed best on ln-normally distributed data. The commonly used reference change value method based on two results (without use of estimated set point) performed worst both on normally...

  11. Food Sources of EPA and DHA in the Diets of American Children, NHANES 2003-2010

    OpenAIRE

    Kranz, Sibylle; Huss, Lyndsey R.; Dobbs-Oates, Jennifer

    2015-01-01

    Objective Dietary eicosapentaenoicacid (EPA) and docosahexaenoic acid (DHA) are found in the highest concentrations in fish and seafood. As important nutrients for brain and eye development and function, their consumption levels are of public health interest, especially in children. This study was conducted toexamine children’sreported consumption of fish and shellfish as well as EPA and DHA intake.Methods Secondary analysis of dietary intake (24-hour recall) and Food Frequency Questionnaire ...

  12. A coupled-enzyme equilibrium method for measuring urea in serum: optimization and evaluation of the AACC study group on urea candidate reference method.

    Science.gov (United States)

    Sampson, E J; Baird, M A; Burtis, C A; Smith, E M; Witte, D L; Bayse, D D

    1980-06-01

    We describe a coupled-enzyme equilibrium method for measuring urea in serum, which is performed on supernates prepared by treating each specimen with Ba(OH)2 and ZnSO4 (Somogyi reagent). Analytical recovery of [14C]urea added to a variety of matrices was essentially complete (mean, 100.6%) for the supernates after precipitation. Nine variables were univariately examined in arriving at the reaction conditions for the method: glutamate dehydrogenase, urease, 2-oxoglutarate, ADP, Tris . HCI, NADH, EDTA, pH, and temperature. The reagent is stable for at least 48 days at--20 degrees C and for 23 days at 4 degrees C. Mean analytical recovery of urea (14 mmol/L) added to seven different specimens (three different matrices) was 100.8%. The analytical linear range of the method extends to 30 mmol of urea per liter. Of 22 potential interferents, only bilirubin at 1 mmol/L (580 mg/L), hemoglobin at 10 g/L, and hydroxyurea at 6 mmol/L showed more than 2% interference. We discuss precision and effects of specimen dilution, and compare results for 100 human serum specimens with those measured for the same specimens with four other urea methods. We examined the effects of measuring a blank, consisting of sample and reagent without urease, with each specimen.

  13. Definition of the upper reference limit for thyroglobulin antibodies according to the National Academy of Clinical Biochemistry guidelines: comparison of eleven different automated methods.

    Science.gov (United States)

    D'Aurizio, F; Metus, P; Ferrari, A; Caruso, B; Castello, R; Villalta, D; Steffan, A; Gaspardo, K; Pesente, F; Bizzaro, N; Tonutti, E; Valverde, S; Cosma, C; Plebani, M; Tozzoli, R

    2017-12-01

    In the last two decades, thyroglobulin autoantibodies (TgAb) measurement has progressively switched from marker of thyroid autoimmunity to test associated with thyroglobulin (Tg) to verify the presence or absence of TgAb interference in the follow-up of patients with differentiated thyroid cancer. Of note, TgAb measurement is cumbersome: despite standardization against the International Reference Preparation MRC 65/93, several studies demonstrated high inter-method variability and wide variation in limits of detection and in reference intervals. Taking into account the above considerations, the main aim of the present study was the determination of TgAb upper reference limit (URL), according to the National Academy of Clinical Biochemistry guidelines, through the comparison of eleven commercial automated immunoassay platforms. The sera of 120 healthy males, selected from a population survey in the province of Verona, Italy, were tested for TgAb concentration using eleven IMA applied on as many automated analyzers: AIA-2000 (AIA) and AIA-CL2400 (CL2), Tosoh Bioscience; Architect (ARC), Abbott Diagnostics; Advia Centaur XP (CEN) and Immulite 2000 XPi (IMM), Siemens Healthineers; Cobas 6000 (COB), Roche Diagnostics; Kryptor (KRY), Thermo Fisher Scientific BRAHMS, Liaison XL (LIA), Diasorin; Lumipulse G (LUM), Fujirebio; Maglumi 2000 Plus (MAG), Snibe and Phadia 250 (PHA), Phadia AB, Thermo Fisher Scientific. All assays were performed according to manufacturers' instructions in six different laboratories in Friuli-Venezia Giulia and Veneto regions of Italy [Lab 1 (AIA), Lab 2 (CL2), Lab 3 (ARC, COB and LUM), Lab 4 (CEN, IMM, KRY and MAG), Lab 5 (LIA) and Lab 6 (PHA)]. Since TgAb values were not normally distributed, the experimental URL (e-URL) was established at 97.5 percentile according to the non-parametric method. TgAb e-URLs showed a significant inter-method variability. Considering the same method, e-URL was much lower than that suggested by manufacturers (m

  14. The location of midfacial landmarks according to the method of establishing the midsagittal reference plane in three-dimensional computed tomography analysis of facial asymmetry

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Sun; Lee, Eun Joo; Lee, Jae Seo; Kang, Byung Cheock; Yoon, Suk Ja [Dental Science Research Institute, Chonnam National University, Gwangju (Korea, Republic of); Song, In Ja [Dept. of Nursing, Kwangju Women' s University, Gwangju (Korea, Republic of)

    2015-12-15

    The purpose of this study was to evaluate the influence of methods of establishing the midsagittal reference plane (MRP) on the locations of midfacial landmarks in the three-dimensional computed tomography (CT) analysis of facial asymmetry. A total of 24 patients (12 male and 12 female; mean age, 22.5 years; age range, 18.2-29.7 years) with facial asymmetry were included in this study. The MRP was established using two different methods on each patient's CT image. The x-coordinates of four midfacial landmarks (the menton, nasion, upper incisor, and lower incisor) were obtained by measuring the distance and direction of the landmarks from the MRP, and the two methods were compared statistically. The direction of deviation and the severity of asymmetry found using each method were also compared. The x-coordinates of the four anatomic landmarks all showed a statistically significant difference between the two methods of establishing the MRP. For the nasion and lower incisor, six patients (25.0%) showed a change in the direction of deviation. The severity of asymmetry also changed in 16 patients (66.7%). The results of this study suggest that the locations of midfacial landmarks change significantly according to the method used to establish the MRP.

  15. Fast and fuzzy multi-objective radiotherapy treatment plan generation for head and neck cancer patients with the lexicographic reference point method (LRPM)

    Science.gov (United States)

    van Haveren, Rens; Ogryczak, Włodzimierz; Verduijn, Gerda M.; Keijzer, Marleen; Heijmen, Ben J. M.; Breedveld, Sebastiaan

    2017-06-01

    Previously, we have proposed Erasmus-iCycle, an algorithm for fully automated IMRT plan generation based on prioritised (lexicographic) multi-objective optimisation with the 2-phase ɛ-constraint (2pɛc) method. For each patient, the output of Erasmus-iCycle is a clinically favourable, Pareto optimal plan. The 2pɛc method uses a list of objective functions that are consecutively optimised, following a strict, user-defined prioritisation. The novel lexicographic reference point method (LRPM) is capable of solving multi-objective problems in a single optimisation, using a fuzzy prioritisation of the objectives. Trade-offs are made globally, aiming for large favourable gains for lower prioritised objectives at the cost of only slight degradations for higher prioritised objectives, or vice versa. In this study, the LRPM is validated for 15 head and neck cancer patients receiving bilateral neck irradiation. The generated plans using the LRPM are compared with the plans resulting from the 2pɛc method. Both methods were capable of automatically generating clinically relevant treatment plans for all patients. For some patients, the LRPM allowed large favourable gains in some treatment plan objectives at the cost of only small degradations for the others. Moreover, because of the applied single optimisation instead of multiple optimisations, the LRPM reduced the average computation time from 209.2 to 9.5 min, a speed-up factor of 22 relative to the 2pɛc method.

  16. A calibration method for the measurement of IR detector spectral responses using a FTIR spectrometer equipped with a DTGS reference cell

    Science.gov (United States)

    Gravrand, Olivier; Wlassow, J.; Bonnefond, L.

    2014-07-01

    Various high performance IR detectors are today available on the market from QWIPs to narrow gap semiconductor photodiodes, which exhibit various spectral features. In the astrophysics community, the knowledge of the detector spectral shape is of first importance. This quantity (spectral QE or response) is usually measured by means of a monochromator followed by an integrating sphere and compared to a calibrated reference detector. This approach is usually very efficient in the visible range, where all optical elements are very well known, particularly the reference detector. This setup is also widely used in the near IR (up to 3μm) but as the wavelength increases, it becomes less efficient. For instance, the internal emittance of integrating spheres in the IR, and the bad knowledge of reference detectors for longer wavelengths tend to degrade the measurement reliability. Another approach may therefore be considered, using a Fourier transform IR spectrometer (FTIR). In this case, as opposed to the monochromator, the tested detector is not in low flux condition, the incident light containing a mix of different wavelengths. Therefore, the reference detector has to be to be sensitive (and known) in the whole spectral band of interest, because it will sense all those wavelengths at the same time. A popular detector used in this case is a Deuterated Triglycine Sulfate thermal detector (DTGS). Being a pyro detetector, the spectral response of such a detector is very flat, mainly limited by its window. However, the response of such a detector is very slow, highly depending on the temporal frequency of the input signal. Moreover, being a differential detector, it doesn't work in DC. In commercial FTIR spectrometers, the source luminance is usually continuously modulated by the moving interferometer, and the result is that the interferogram mixes optical spectral information (optical path difference) and temporal variations (temporal frequency) so that the temporal

  17. Implementation of the method air-kerma product area in KAP camera calibration with reference qualities of X-ray series at the SSDL RQR of Mexico

    International Nuclear Information System (INIS)

    Cejudo, Jesus; Tovar, Victor M.

    2013-01-01

    The X-Ray machines, at a reference laboratory for the instrument calibration in diagnostic radiology, should compliance with the ISO requirements. Sometimes there is not available as much laboratories as needed in Latin American countries. So this project shows the KAP ionization chamber implementation method using the TRS-457 radiation quality from the IAEA at the SSDL of Mexico. The KAP instruments calibration method consists in doing a substitution comparison using a standard reference with traceability to a primary laboratory and a transmission-monitoring chamber that measures the number of photons of the X-ray primary beam. A KAP chamber calibration requires a special array that consists in collocating the chamber in two different positions of its calibration process. Then, with air kerma-area product coefficient together with a corrected electrometer measure at referential conditions, the patient dosimetry magnitudes are calculated. The dosimetry necessity at hospitals always will be in function of possessing a highly reliable calibration coefficient chamber for making these measures. That dosimetry results will help in reducing the total or partial irradiation emitted to the human body of the patient. This is how stochastic risks will be lessened due to diagnostic studies. The purpose of this project is to have a synergy with calibration for making known that the SSDL of Mexico has the technical capacity to act as a link between primary standard dosimetry laboratories and the ionizing radiation equipment users who require that their KAP chamber have traceability from the primary standard to the user. (author)

  18. Towards absolute quantification of allergenic proteins in food--lysozyme in wine as a model system for metrologically traceable mass spectrometric methods and certified reference materials.

    Science.gov (United States)

    Cryar, Adam; Pritchard, Caroline; Burkitt, William; Walker, Michael; O'Connor, Gavin; Burns, Duncan Thorburn; Quaglia, Milena

    2013-01-01

    Current routine food allergen quantification methods, which are based on immunochemistry, offer high sensitivity but can suffer from issues of specificity and significant variability of results. MS approaches have been developed, but currently lack metrological traceability. A feasibility study on the application of metrologically traceable MS-based reference procedures was undertaken. A proof of concept involving proteolytic digestion and isotope dilution MS for quantification of protein allergens in a food matrix was undertaken using lysozyme in wine as a model system. A concentration of lysozyme in wine of 0.95 +/- 0.03 microg/g was calculated based on the concentrations of two peptides, confirming that this type of analysis is viable at allergenically meaningful concentrations. The challenges associated with this promising method were explored; these included peptide stability, chemical modification, enzymatic digestion, and sample cleanup. The method is suitable for the production of allergen in food certified reference materials, which together with the achieved understanding of the effects of sample preparation and of the matrix on the final results, will assist in addressing the bias of the techniques routinely used and improve measurement confidence. Confirmation of the feasibility of MS methods for absolute quantification of an allergenic protein in a food matrix with results traceable to the International System of Units is a step towards meaningful comparison of results for allergen proteins among laboratories. This approach will also underpin risk assessment and risk management of allergens in the food industry, and regulatory compliance of the use of thresholds or action levels when adopted.

  19. Open Letter from the GAC-EPA to the Chairman of the PFGB EPA

    CERN Multimedia

    GAC-EPA

    2012-01-01

    Following the publication by the Chairman of the Pension Fund Governing Board of  the Spring report of the Pension Fund in the CERN Bulletin issue dated 25 July 2012 (Nos 30 & 31), the GAC-EPA has reacted through an open letter. See www.gac-epa.org under Announcement.

  20. Scenario sensitivity analyses performed on the PRESTO-EPA LLW risk assessment models

    International Nuclear Information System (INIS)

    Bandrowski, M.S.

    1988-01-01

    The US Environmental Protection Agency (EPA) is currently developing standards for the land disposal of low-level radioactive waste. As part of the standard development, EPA has performed risk assessments using the PRESTO-EPA codes. A program of sensitivity analysis was conducted on the PRESTO-EPA codes, consisting of single parameter sensitivity analysis and scenario sensitivity analysis. The results of the single parameter sensitivity analysis were discussed at the 1987 DOE LLW Management Conference. Specific scenario sensitivity analyses have been completed and evaluated. Scenario assumptions that were analyzed include: site location, disposal method, form of waste, waste volume, analysis time horizon, critical radionuclides, use of buffer zones, and global health effects