WorldWideScience

Sample records for epa reference dose

  1. The US EPA reference dose for methylmercury: sources of uncertainty

    International Nuclear Information System (INIS)

    Rice, D.C.

    2004-01-01

    The US Environmental Protection Agency (EPA) derived a reference dose for methylmercury in 2001, based on an extensive analysis by the National Research Council (NRC) of the National Academy of Sciences. The NRC performed benchmark dose analysis on a number of endpoints from three longitudinal prospective studies: the Seychelles Islands, the Faroe Islands, and the New Zealand studies. Adverse effects were reported in the latter two studies, but not in the Seychelles study. The NRC also performed an integrative analysis of all three studies. Dose conversion from cord blood or maternal hair mercury concentration was performed by EPA using a one-compartment pharmacokinetic model. A total uncertainty factor of 10 was applied for intrahuman pharmacokinetic and pharmacodynamic variability. There are numerous decisions made by the NRC/EPA that could greatly affect the value of the reference dose (RfD). Some of these include the choice of a linear model for the relationship between mercury body burden and neuropsychological performance, the choice of values of P 0 and the benchmark response, the use of the 'critical study/critical endpoint' approach in the interpretation of the maternal body burden that corresponds to the RfD, the use of central tendencies in a one-compartment pharmacokinetic model rather than the inclusion of the distributions of variables for the population of reproductive-age women, the assumption of unity for the ratio of fetal cord blood to maternal blood methylmercury concentrations, the choice of a total of 10 as an uncertainty factor, and the lack of dose-response analysis for other health effects such as cardiovascular disease. In addition, it may be argued that derivation of a RfD for methylmercury is inappropriate, given that there does not appear to be a threshold for adverse neuropsychological effects based on available data

  2. EPA's Benchmark Dose Modeling Software

    Science.gov (United States)

    The EPA developed the Benchmark Dose Software (BMDS) as a tool to help Agency risk assessors facilitate applying benchmark dose (BMD) method’s to EPA’s human health risk assessment (HHRA) documents. The application of BMD methods overcomes many well know limitations ...

  3. Proposed Oral Reference Dose (RfD) for Barium and Compounds (Final Report, 2004)

    Science.gov (United States)

    This document is the final report from the 2004 external peer review of the Proposed Oral Reference Dose (RfD) for Barium and Compounds, prepared by the U.S. Environmental Protection Agency (EPA), National Center for Environmental Assessment (NCEA), for the Integrated Risk...

  4. Phthalate exposure, even below US EPA reference doses, was associated with semen quality and reproductive hormones: Prospective MARHCS study in general population.

    Science.gov (United States)

    Chen, Qing; Yang, Huan; Zhou, Niya; Sun, Lei; Bao, Huaqiong; Tan, Lu; Chen, Hongqiang; Ling, Xi; Zhang, Guowei; Huang, Linping; Li, Lianbing; Ma, Mingfu; Yang, Hao; Wang, Xiaogang; Zou, Peng; Peng, Kaige; Liu, Taixiu; Shi, Xiefei; Feng, Dejian; Zhou, Ziyuan; Ao, Lin; Cui, Zhihong; Cao, Jia

    2017-07-01

    Environment-Protection-Agency Reference Doses (EPA RfDs) for phthalate intakes are based on limited evidence, especially regarding low-dose male-reproductive toxicity. This study investigates the association between phthalate exposure and semen parameters and reproductive hormones in a general population with low phthalate exposure compared to the EPA RfDs. The MARHCS (Male-Reproductive-Health-in-Chongqing-College-Students) cohort recruited 796 male students, who experienced a relocation of campuses and shifting environmental exposure. Urine, semen and blood before and after the relocation was collected and investigated for: (1) the associations between 13 urinary phthalate metabolites and 11 semen/hormone outcomes (five semen parameters including semen volume, sperm concentration, total sperm number, progressive motility, normal morphology) and six serum reproductive hormones including estradiol, follicle-stimulating hormone, luteinizing hormone, prolactin, progesterone, testosterone; (2) re-analysis of the metabolite-outcome associations in the subjects with estimated phthalate intakes below the RfDs; (3) a change in phthalate metabolites and change in semen/hormone outcomes after the relocation; (4) the association between these changes. (1) All but two semen/hormone outcomes were associated with at least one phthalate metabolite, e.g., each quartile monoethyl phthalate was associated with a 5.3%, 5.7% and 2.6% decrease of sperm concentration, total sperm number and progressive motility respectively. (2) In the subjects with phthalate intakes below the RfDs, these metabolite-outcome associations remained significant. (3) All metabolites except mono(2-ethylhexyl) phthalate declined after relocation (Phormone increased (by 5.9%, 25.0%, 34.2% and 10.0%) and testosterone decreased (by 7.0%). (4) The changes in semen volume, normal morphology, estradiol and testosterone, but not the change in luteinizing hormone after relocation, were associated with the changes in

  5. Hanford Dose Overview Program. Comparison of AIRDOS-EPA and Hanford site dose codes

    International Nuclear Information System (INIS)

    Aaberg, R.L.; Napier, B.A.

    1985-11-01

    Radiation dose commitments for persons in the Hanford environs calculated using AIRDOS-EPA were compared with those calculated using a suite of Hanford codes: FOOD, PABLM, DACRIN, and KRONIC. Dose commitments to the population and to the maximally exposed individual (MI) based on annual releases of eight radionuclides from the N-Reactor, were calculated by these codes. Dose commitments from each pathway to the total body, lung, thyroid, and lower large intestine (LLI) are given for the population and MI, respectively. 11 refs., 25 tabs

  6. EPA`s program for risk assessment guidelines: Quantification issues

    Energy Technology Data Exchange (ETDEWEB)

    Dourson, M.L. [Environmental Protection Agency, Washington, DC (United States)

    1990-12-31

    The quantitative procedures associated with noncancer risk assessment include reference dose (RfD), benchmark dose, and severity modeling. The RfD, which is part of the EPA risk assessment guidelines, is an estimation of a level that is likely to be without any health risk to sensitive individuals. The RfD requires two major judgments: the first is choice of a critical effect(s) and its No Observed Adverse Effect Level (NOAEL); the second judgment is choice of an uncertainty factor. This paper discusses major assumptions and limitations of the RfD model.

  7. Introduction to benchmark dose methods and U.S. EPA's benchmark dose software (BMDS) version 2.1.1

    International Nuclear Information System (INIS)

    Davis, J. Allen; Gift, Jeffrey S.; Zhao, Q. Jay

    2011-01-01

    Traditionally, the No-Observed-Adverse-Effect-Level (NOAEL) approach has been used to determine the point of departure (POD) from animal toxicology data for use in human health risk assessments. However, this approach is subject to substantial limitations that have been well defined, such as strict dependence on the dose selection, dose spacing, and sample size of the study from which the critical effect has been identified. Also, the NOAEL approach fails to take into consideration the shape of the dose-response curve and other related information. The benchmark dose (BMD) method, originally proposed as an alternative to the NOAEL methodology in the 1980s, addresses many of the limitations of the NOAEL method. It is less dependent on dose selection and spacing, and it takes into account the shape of the dose-response curve. In addition, the estimation of a BMD 95% lower bound confidence limit (BMDL) results in a POD that appropriately accounts for study quality (i.e., sample size). With the recent advent of user-friendly BMD software programs, including the U.S. Environmental Protection Agency's (U.S. EPA) Benchmark Dose Software (BMDS), BMD has become the method of choice for many health organizations world-wide. This paper discusses the BMD methods and corresponding software (i.e., BMDS version 2.1.1) that have been developed by the U.S. EPA, and includes a comparison with recently released European Food Safety Authority (EFSA) BMD guidance.

  8. Fast in vivo volume dose reconstruction via reference dose perturbation

    International Nuclear Information System (INIS)

    Lu, Weiguo; Chen, Mingli; Mo, Xiaohu; Parnell, Donald; Olivera, Gustavo; Galmarini, Daniel

    2014-01-01

    Purpose: Accurate on-line reconstruction of in-vivo volume dose that accounts for both machine and patient discrepancy is not clinically available. We present a simple reference-dose-perturbation algorithm that reconstructs in-vivo volume dose fast and accurately. Methods: We modelled the volume dose as a function of the fluence map and density image. Machine (output variation, jaw/leaf position errors, etc.) and patient (setup error, weight loss, etc.) discrepancies between the plan and delivery were modelled as perturbation of the fluence map and density image, respectively. Delivered dose is modelled as perturbation of the reference dose due to change of the fluence map and density image. We used both simulated and clinical data to validate the algorithm. The planned dose was used as the reference. The reconstruction was perturbed from the reference and accounted for output-variations and the registered daily image. The reconstruction was compared with the ground truth via isodose lines and the Gamma Index. Results: For various plans and geometries, the volume doses were reconstructed in few seconds. The reconstruction generally matched well with the ground truth. For the 3%/3mm criteria, the Gamma pass rates were 98% for simulations and 95% for clinical data. The differences mainly appeared on the surface of the phantom/patient. Conclusions: A novel reference-dose-perturbation dose reconstruction model is presented. The model accounts for machine and patient discrepancy from planning. The algorithm is simple, fast, yet accurate, which makes online in-vivo 3D dose reconstruction clinically feasible.

  9. Quality Assurance Testing of Version 1.3 of U.S. EPA Benchmark Dose Software (Presentation)

    Science.gov (United States)

    EPA benchmark dose software (BMDS) issued to evaluate chemical dose-response data in support of Agency risk assessments, and must therefore be dependable. Quality assurance testing methods developed for BMDS were designed to assess model dependability with respect to curve-fitt...

  10. Development of a Reference Dose for Perchlorate: Current Issues and Status

    Science.gov (United States)

    Pleus, R. C.; Goodman, G.; Mattie, D. R.

    2000-01-01

    The perchlorate anion (ClO4) is typically manufactured as the ammonium salt. The most common use of ammonium perchlorate is in the aerospace program as a component of solid rocket fuel. The perchlorate anion is exceedingly stable under environmental conditions and has been found in ground and surface waters in CA, NV, UT, AZ, TX, AK, NY, MD, WV and FL. The National Center for Environmental Assessment (NCEA) of the U.S. Environmental Protection Agency (US EPA) is in the process of developing an oral reference dose (RfD) for perchlorate. An oral RfD is a body-weight-adjusted dose that can be consumed daily over an entire lifetime with the expectation of no adverse health effects. Once developed, the new RfD will be used by US EPA as the basis of a safe-drinking-water level (SDWL) guideline. US EPA and regional regulatory agencies will then jointly or separately propose clean-up action levels for ground and surface waters at contaminated sites. The toxicological database on CIO4- as of March 1997 was determined by an expert peer-review panel to be inadequate for the purpose of deriving an oral RfD. For example, little or no experimental data existed on the subchronic, reproductive, or developmental toxicity of perchlorate. To fill gaps in the toxicological database, eight animal studies were designed by a government-industry consortium that included US EPA and AFRL. These studies were performed in 1997-1998. It has been known for many years that in the thyroid, high doses of perchlorate block the function of iodide by competing for iodide binding sites. Perchlorate was used in the 1950s-60s as a treatment for Graves' disease (a hyperthyroid condition). Because of what was already known about the pharmacological mode of action of perchlorate, specific concerns addressed in the design of the recent animal studies included the potential for developmental toxicity, notably neurological development. Upon review of complete study reports from four of the studies and

  11. EPA flow reference method testing and analysis: Findings report

    International Nuclear Information System (INIS)

    1999-06-01

    This report describes an experimental program sponsored by the US Environmental Protection Agency (EPA) to evaluate potential improvements to the Agency's current reference method for measuring volumetric flow (Method 2, 40 CFR Part 60, Appendix B). Method 2 (Determination of Stack Gas Velocity and Volumetric Flow Rate (Type S Pitot Tube)) specifies measurements to determine volumetric flow, but does not prescribe specific procedures to account for yaw or pitch angles of flow when the flow in the stack is not axial. Method 2 also allows the use of only two probe types, the Type S and the Prandtl

  12. Reference Dose Rates for Fluoroscopy Guided Interventions

    International Nuclear Information System (INIS)

    Geleijns, J.; Broerse, J.J.; Hummel, W.A.; Schalij, M.J.; Schultze Kool, L.J.; Teeuwisse, W.; Zoetelief, J.

    1998-01-01

    The wide diversity of fluoroscopy guided interventions which have become available in recent years has improved patient care. They are being performed in increasing numbers, particularly at departments of cardiology and radiology. Some procedures are very complex and require extended fluoroscopy times, i.e. longer than 30 min, and radiation exposure of patient and medical staff is in some cases rather high. The occurrence of radiation-induced skin injuries on patients has shown that radiation protection for fluoroscopy guided interventions should not only be focused on stochastic effects, i.e. tumour induction and hereditary risks, but also on potential deterministic effects. Reference dose levels are introduced by the Council of the European Communities as an instrument to achieve optimisation of radiation protection in radiology. Reference levels in conventional diagnostic radiology are usually expressed as entrance skin dose or dose-area product. It is not possible to define a standard procedure for complex interventions due to the large inter-patient variations with regard to the complexity of specific interventional procedures. Consequently, it is not realistic to establish a reference skin dose or dose-area product for complex fluoroscopy guided interventions. As an alternative, reference values for fluoroscopy guided interventions can be expressed as the entrance dose rates on a homogeneous phantom and on the image intensifier. A protocol has been developed and applied during a nationwide survey of fluoroscopic dose rate during catheter ablations. From this survey reference entrance dose rates of respectively 30 mGy.min -1 on a polymethylmethacrylate (PMMA) phantom with a thickness of 21 cm, and of 0.8 μGy.s -1 on the image intensifier have been derived. (author)

  13. Establishing Local Reference Dose Values and Optimisation Strategies

    International Nuclear Information System (INIS)

    Connolly, P.; Moores, B.M.

    2000-01-01

    The revised EC Patient Directive 97/43 EURATOM introduces the concepts of clinical audit, diagnostic reference levels and optimisation of radiation protection in diagnostic radiology. The application of reference dose levels in practice involves the establishment of reference dose values as actual measurable operational quantities. These values should then form part of an ongoing optimisation and audit programme against which routine performance can be compared. The CEC Quality Criteria for Radiographic Images provides guidance reference dose values against which local performance can be compared. In many cases these values can be improved upon quite considerably. This paper presents the results of a local initiative in the North West of the UK aimed at establishing local reference dose values for a number of major hospital sites. The purpose of this initiative is to establish a foundation for both optimisation strategies and clinical audit as an ongoing and routine practice. The paper presents results from an ongoing trial involving patient dose measurements for several radiological examinations upon the sites. The results of an attempt to establish local reference dose values from measured dose values and to employ them in optimisation strategies are presented. In particular emphasis is placed on the routine quality control programmes necessary to underpin this strategy including the effective data management of results from such programmes and how they can be employed to optimisation practices. (author)

  14. Hg0 and HgCl2 Reference Gas Standards: NIST Traceability and Comparability (And EPA ALT Methods for Hg and HCl )

    Science.gov (United States)

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the tru...

  15. Effects of an open-label pilot study with high-dose EPA/DHA concentrates on plasma phospholipids and behavior in children with attention deficit hyperactivity disorder

    Directory of Open Access Journals (Sweden)

    Hutchins Heather L

    2007-07-01

    Full Text Available Abstract Background Attention deficit hyperactivity disorder (ADHD is the most common neurological condition in children. This pilot study evaluated the effects of high-dose eicosapentaenoic acid (EPA and docosahexaenoic acid (DHA supplementation on the isolated plasma phospholipids and behavior in children with ADHD (primarily inattentive subtype and combined subtype. Methods Nine children were initially supplemented with 16.2 g EPA/DHA concentrates per day. The dosage was adjusted dependent on the ratio of arachidonic acid (AA to EPA in the isolated plasma phospholipids at four weeks to reach a level normally found in the Japanese population. Results At the end of the eight-week study, supplementation resulted in significant increases in EPA and DHA, as well as a significant reduction in the AA:EPA ratio (20.78 ± 5.26 to 5.95 ± 7.35, p Conclusion The findings of this small pilot study suggest supplementation with high-dose EPA/DHA concentrates may improve behavior in children with ADHD.

  16. Comparison between dose values specified at the ICRU reference point and the mean dose to the planning target volume

    International Nuclear Information System (INIS)

    Kukoowicz, Pawel F.; Mijnheer, Bernard J.

    1997-01-01

    Background and purpose: To compare dose values specified at the reference point, as recommended by the International Commission on Radiation Units and Measurements, ICRU, and the mean dose to the planning target volume, PTV. Material and methods: CT-based dose calculations were performed with a 3-D treatment planning system for 6 series of patients treated for bladder, brain, breast, lung, oropharynx and parotid gland tumour. All patients were arbitrarily chosen from a set of previously treated patients irradiated with a two- or three-field technique using customised blocks. Appropriate wedge angles and beam weights were chosen to make the dose distribution as homogeneous as possible. Results: The dose at the ICRU reference point was generally higher than the mean dose to the PTV. The difference between the ICRU reference dose and the mean dose to the PTV for an individual patient was less than 3% in 88% of cases and less than 2% in 72% of the cases. The differences were larger in those patients where the dose distribution is significantly influenced by the presence of lungs or air gaps. For each series of patients the mean difference between the ICRU reference dose and the mean dose to the PTV was calculated. The difference between these two values never exceeded 2%. Because not all planning systems are able to calculate the mean dose to the PTV, the concept of the mean central dose, the mean of the dose values at the centre of the PTV in each CT slice, has been introduced. The mean central dose was also calculated for the same patients and was closer to the mean dose to the PTV than the ICRU reference dose. Conclusion: The mean dose to the PTV is well estimated by either the ICRU reference dose or the mean central dose for a variety of treatment techniques for common types of cancer

  17. Issues raised by the reference doses for perfluorooctane sulfonate and perfluorooctanoic acid.

    Science.gov (United States)

    Dong, Zhaomin; Bahar, Md Mezbaul; Jit, Joytishna; Kennedy, Bruce; Priestly, Brian; Ng, Jack; Lamb, Dane; Liu, Yanju; Duan, Luchun; Naidu, Ravi

    2017-08-01

    On 25th May 2016, the U.S. EPA released reference doses (RfDs) for Perfluorooctane Sulfonate (PFOS) and Perfluorooctanoic Acid (PFOA) of 20ng/kg/day, which were much more conservative than previous values. These RfDs rely on the choices of animal point of departure (PoD) and the toxicokinetics (TK) model. At this stage, considering that the human evidence is not strong enough for RfD determination, using animal data may be appropriate but with more uncertainties. In this article, the uncertainties concerning RfDs from the choices of PoD and TK models are addressed. Firstly, the candidate PoDs should include more critical endpoints (such as immunotoxicity), which may lead to lower RfDs. Secondly, the reliability of the adopted three-compartment TK model is compromised: the parameters are not non-biologically plausible; and this TK model was applied to simulate gestation and lactation exposures, while the two exposure scenarios were not actually included in the model structure. Copyright © 2017. Published by Elsevier Ltd.

  18. Patient dose reference values for explorations of radiodiagnostic

    International Nuclear Information System (INIS)

    Vano, E.; Gonzalez, L.; Moran, P.; Calzado, A.; Delgado, V.; Ruiz, M.J.

    1992-01-01

    Among the results of the research programs developed in the European Community dealing with radiological protection, dose estimation and quality control in radiodiagnostics, the preparation of a document on Quality criteria for radiodiagnostic images is worthy of note. This document proposes criteria for image quality and patient dose reference values for explorations of thorax, cranium, lumbar region, pelvis, urinary tract and breast. Said reference values, while indicative, are merely an average approximation, from which the radiodiagnostic services of each area may differ significantly, as can be deduced from a EC-coordinated project. With this in mind, and following a strategy applied in the EC to establish said reference values, in this report, provisional reference values, specific for Spain, are proposed for simple examinations (those analyzed by the group of EC experts, among others) and complex probes (intravenous urography, opaque enema and esophagogastroduodenal enema). (author)

  19. Studies on the reference Korean and estimation of radiation exposure dose

    International Nuclear Information System (INIS)

    Kim, Y.J.; Lee, K.S.; Chun, K.J.; Kim, J.B.; Chung, G.H.; Kim, S.R.

    1982-01-01

    For the purpose of establishment of Reference Korean and estimation of internal and external exposure doses in the Reference Korean, we have surveyed reference values for Koreans such as physical standards including height, weight, and body surface area, food consumption rate of daily intake of radioactive substances and exposure dose from natural radiation. (Author)

  20. National reference doses for dental cephalometric radiography.

    Science.gov (United States)

    Holroyd, J R

    2011-12-01

    Diagnostic reference levels (DRLs) are an important tool in the optimisation of clinical radiography. Although national DRLs are provided for many diagnostic procedures including dental intra-oral radiography, there are currently no national DRLs set for cephalometric radiography. In the absence of formal national DRLs, the Health Protection Agency (HPA) has previously published National Reference Doses (NRDs) covering a wide range of diagnostic X-ray examinations. The aim of this study was to determine provisional NRDs for cephalometric radiography. Measurements made by the Dental X-ray Protection Service (DXPS) of the HPA, as part of the cephalometric X-ray equipment testing service provided to dentists and dental trade companies throughout the UK, were used to derive provisional NRDs. Dose-area product measurements were made on 42 X-ray sets. Third quartile dose-area product values for adult and child lateral cephalometric radiography were found to be 41 mGy cm² and 25 mGy cm², respectively, with individual measurements ranging from 3 mGy cm² to 108 mGy cm². This report proposes provisional NRDs of 40 mGy cm² and 25 mGy cm² for adult and child lateral cephalometric radiographs, respectively; these doses could be considered by employers when establishing their local DRLs.

  1. Reference doses and patient size in paediatric radiology

    International Nuclear Information System (INIS)

    Hart, D.; Wall, B.; Shrimpton, P.

    2000-01-01

    There is a wide range in patient size from a newborn baby to a 15 year old adolescent. Reference doses for paediatric radiology can sensibly be established only for specific sizes of children. Here five standard sizes have been chosen, representing 0 (newborn), 1, 5, 10 and 15 year old patients. This selection of standard ages has the advantage of matching the paediatric mathematical phantoms which are often used in Monte Carlo organ dose calculations. A method has been developed for calculating factors for normalising doses measured on individual children to those for the nearest standard-sized 'child'. These normalisation factors for entrance surface dose (ESD) and dose-area product (DAP) measurements depend on the thickness of the real child, the thickness of the nearest standard 'child', and an effective linear attenuation coefficient (μ) which is itself a function of the x-ray spectrum, the field size, and whether or not an antiscatter grid is used. Entrance and exit dose measurements were made with phantom material representing soft tissue to establish μ values for abdominal and head examinations, and with phantom material representing lung for chest examinations. These measurements of μ were confirmed and extended to other x-ray spectra and field sizes by Monte Carlo calculations. The normalisation factors are tabulated for ESD measurements for specific radiographic projections through the head and trunk, and for DAP measurements for complete multiprojection examinations in the trunk. The normalisation factors were applied to European survey data for entrance surface dose and dose-area product measurements to derive provisional reference doses for common radiographic projections and for micturating cystourethrography (MCU) examinations - the most frequent fluoroscopic examination on children. (author)

  2. EPA requirements for the uranium fuel cycle

    International Nuclear Information System (INIS)

    Dunster, H.J.

    1975-01-01

    The draft Environmental Statement issued by the Environmental Protection Agency (EPA) in the United States in preparation for Proposed Rulemaking Action concerning 'Environmental radiation protection requirements for normal operations of activities in the uranium fuel cycle' is summarized and discussed. The standards proposed by the EPA limit the annual dose equivalents to any member of the public, and also the releases of radionuclides to the 'general environment' for each gigawatt year of electrical energy produced. These standards were based on cost effectiveness arguements and levels and correspond to the ICRP recommendation to keep all exposures as low as reasonably achievable, economic and social factors being taken into account. They should be clearly distinguished from dose limits, although the EPA does not make this at all clear. The EPA seems to have shown an unexpected lack of understanding of the recommendations of ICRP Publication 9 (1965) and an apparent unawareness of ICRP Publication 22 (1973), and has therefore wrongly presented the new standards as a significant change in policy. The EPA has reviewed the information on the likely level of dose equivalents to members of the public and the likely cost reductions, thereby quantifying existing principles as applied to the fuel cycle as a whole. The EPA has stated that its proposals could be achieved as a cost in the region of Pound100,000 per death (or major genetic defect). It is pointed out that the EPA's use of the term 'waste' to exclude liquid and gaseous effluents may cause confusion. (U.K.)

  3. ICRU reference dose in an era of intensity-modulated radiation therapy clinical trials: Correlation with planning target volume mean dose and suitability for intensity-modulated radiation therapy dose prescription

    International Nuclear Information System (INIS)

    Yaparpalvi, Ravindra; Hong, Linda; Mah, Dennis; Shen Jin; Mutyala, Subhakar; Spierer, Marnee; Garg, Madhur; Guha, Chandan; Kalnicki, Shalom

    2008-01-01

    Background and Purpose: IMRT clinical trials lack dose prescription and specification standards similar to ICRU standards for two- and three-dimensional external beam planning. In this study, we analyzed dose distributions for patients whose treatment plans incorporated IMRT, and compared the dose determined at the ICRU reference point to the PTV doses determined from dose-volume histograms. Additionally, we evaluated if ICRU reference type single-point dose prescriptions are suitable for IMRT dose prescriptions. Materials and methods: For this study, IMRT plans of 117 patients treated at our institution were randomly selected and analyzed. The treatment plans were clinically applied to the following disease sites: abdominal (11), anal (10), brain (11), gynecological (15), head and neck (25), lung (15), male pelvis (10) and prostate (20). The ICRU reference point was located in each treatment plan following ICRU Report 50 guidelines. The reference point was placed in the central part of the PTV and at or near the isocenter. In each case, the dose was calculated and recorded to this point. For each patient - volume and dose (PTV, PTV mean, median and modal) information was extracted from the planned dose-volume histogram. Results: The ICRU reference dose vs PTV mean dose relationship in IMRT exhibited a weak positive association (Pearson correlation coefficient 0.63). In approximately 65% of the cases studied, dose at the ICRU reference point was greater than the corresponding PTV mean dose. The dose difference between ICRU reference and PTV mean doses was ≤2% in approximately 79% of the cases studied (average 1.21% (±1.55), range -4% to +4%). Paired t-test analyses showed that the ICRU reference doses and PTV median doses were statistically similar (p = 0.42). The magnitude of PTV did not influence the difference between ICRU reference and PTV mean doses. Conclusions: The general relationship between ICRU reference and PTV mean doses in IMRT is similar to that

  4. Dose distribution in organs: patient-specific phantoms versus reference phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, I.V.B., E-mail: isabelle.lacerda@ufpe.br [Universidade Federal de Pernambuco (UFPE), Recife (Brazil); Vieira, J.W. [Instituto Federal de Pernambuco (IFPE), Recife (Brazil); Oliveira, M.L.; Lima, F.R.A. [Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE/CNEN-PB), Recife (Brazil)

    2017-07-01

    Discrepancies between ICRP phantoms and real patients lead to disparities on patient-dose estimations. This paper aims to compare distribution of dose in organs of male/female specific-phantoms and ICRP reference phantoms. The absorbed dose estimation was performed using the EGSnrc Monte Carlo code and a parallel source algorithm. In this work were used a patient-specific phantom for a man (1.73m/70.3kg) and another for a woman (1.63m/60.3kg) and the male and female ICRP reference phantoms. The comparison of the absorbed dose from each phantom gender was performed using the relative error. The results were expressed in terms of conversion coefficients to brain, lungs, liver and kidneys. The greatest absolute relative error between the organs of the patient-specific phantom and the reference phantom was 22.92% in the liver and 62.84% in the kidneys, respectively for man and woman. There are errors that cannot be disregarded. This paper shows the need for a specific study for each patient or for the population of each country, since there are different body types, which affects the distribution of the organ doses. (author)

  5. Dose distribution in organs: patient-specific phantoms versus reference phantoms

    International Nuclear Information System (INIS)

    Lacerda, I.V.B.; Vieira, J.W.; Oliveira, M.L.; Lima, F.R.A.

    2017-01-01

    Discrepancies between ICRP phantoms and real patients lead to disparities on patient-dose estimations. This paper aims to compare distribution of dose in organs of male/female specific-phantoms and ICRP reference phantoms. The absorbed dose estimation was performed using the EGSnrc Monte Carlo code and a parallel source algorithm. In this work were used a patient-specific phantom for a man (1.73m/70.3kg) and another for a woman (1.63m/60.3kg) and the male and female ICRP reference phantoms. The comparison of the absorbed dose from each phantom gender was performed using the relative error. The results were expressed in terms of conversion coefficients to brain, lungs, liver and kidneys. The greatest absolute relative error between the organs of the patient-specific phantom and the reference phantom was 22.92% in the liver and 62.84% in the kidneys, respectively for man and woman. There are errors that cannot be disregarded. This paper shows the need for a specific study for each patient or for the population of each country, since there are different body types, which affects the distribution of the organ doses. (author)

  6. Reference dose levels for dental periapical radiography in Chonnam Province

    International Nuclear Information System (INIS)

    Han, Mi Ra; Kang, Byung Cheol; Yoon, Suk Ja; Lee, Jae Seo; Kim, Young Hee

    2009-01-01

    To establish reference doses of periapical radiography in Chonnam Province, Korea. The target-skin distances were measured for dental patient's 1235 exposures including 345 mandibular molar areas. Each periapical radiation exposure was simulated with exactly the same patients exposure parameters and the simulated radiation doses were measured utilizing Mult-O-Meter (Unfors Instruments, Billadal, Sweden). The measurements were done in 44 dental clinics with 49 dental x-ray sets in Chonnam Province for one or two weeks at each dental clinic during year 2006. The third quartile patient surface doses were 2.8 mGy for overall periapical exposures and 3.2 mGy for periapical mandibular molar exposures. The third quartile patient surface doses in Chonnam Province can be used as a guide to accepted clinical practice to reduce patient radiation exposure for the surveyed reference doses were below the recommended dental periapical radiography dose of 7 mGy by IAEA.

  7. Reference dose levels for dental periapical radiography in Chonnam Province

    Energy Technology Data Exchange (ETDEWEB)

    Han, Mi Ra; Kang, Byung Cheol; Yoon, Suk Ja [Department of Oral and Maxillofacial Radiology, College of Dentistry, Dental Science Research Institute, Chonnam National University, Gwangju (Korea, Republic of); Lee, Jae Seo [Department of Oral and Maxillofacial Radiology, Chonnan National University Hospital, Gwangju (Korea, Republic of); Kim, Young Hee [Department of Oral and Maxillofacial Radiology, Hallym University Sacred Heart Hospital, Chuncheon (Korea, Republic of)

    2009-12-15

    To establish reference doses of periapical radiography in Chonnam Province, Korea. The target-skin distances were measured for dental patient's 1235 exposures including 345 mandibular molar areas. Each periapical radiation exposure was simulated with exactly the same patients exposure parameters and the simulated radiation doses were measured utilizing Mult-O-Meter (Unfors Instruments, Billadal, Sweden). The measurements were done in 44 dental clinics with 49 dental x-ray sets in Chonnam Province for one or two weeks at each dental clinic during year 2006. The third quartile patient surface doses were 2.8 mGy for overall periapical exposures and 3.2 mGy for periapical mandibular molar exposures. The third quartile patient surface doses in Chonnam Province can be used as a guide to accepted clinical practice to reduce patient radiation exposure for the surveyed reference doses were below the recommended dental periapical radiography dose of 7 mGy by IAEA.

  8. A novel self-micro-emulsifying delivery system (SMEDS) formulation significantly improves the fasting absorption of EPA and DHA from a single dose of an omega-3 ethyl ester concentrate.

    Science.gov (United States)

    Qin, Yan; Nyheim, Hilde; Haram, Else Marie; Moritz, Joseph M; Hustvedt, Svein Olaf

    2017-10-16

    Absorption of EPA and DHA from Omega-3-acid ethyl ester (EE) concentrate supplements occurs most efficiently when taken in context of a fatty meal; adequate fat intake is required to release bile salts that emulsify and pancreatic enzymes that digest omega-3-containing lipids in the intestine. Current guidelines recommend reduction in fat intake and therefore there is a need to optimize the absorption of Omega-3 in those consuming low-fat or no-fat meals. To this end, BASF has developed an Absorption Acceleration Technology, a novel self-micro-emulsifying delivery system (SMEDS) formulation of highly concentrated Omega-3-acid EE which enables rapid emulsification and microdroplet formation upon entering the aqueous environment of the gut therefore enhances the absorption. Two separate single dose, crossover studies were conducted to determine the relative bioavailability of omega-3-acid EE concentrate, either as a novel SMEDS formulation (PRF-021) or as control, in healthy fasted male and female adults at two dose levels (Study 1 "low dose": 630 mg EPA + DHA in PRF-021 vs. 840 mg EPA + DHA in control; Study 2 "high dose": 1680 mg EPA + DHA in PRF-021 vs. 3360 mg EPA + DHA in control). Blood samples were collected immediately before supplementation and at defined time intervals for 48 h. Plasma concentration of total EPA and DHA were determined for pharmacokinetic analysis, area under the curve (AUC) and maximum observed concentration (C max ) was determined. Total EPA plus DHA absorption from SMEDS formulation PRF-021 were 6.4 and 11.5 times higher compared to control in low- and high-dose studies respectively, determined as the ratio of baseline corrected, dose normalized AUC 0-24h of PRF-021 over that of control. EPA and DHA individually showed differing levels of enhancement: the AUC 0-24h ratio for EPA was 23.8 and 25.7 in low and high dose studies, respectively, and the AUC 0-24h ratio for DHA was 3.6 and 5.6 in low and high dose studies

  9. The establishment and use of dose reference levels in general paediatric radiology

    International Nuclear Information System (INIS)

    Marsden, P.J.; Hardwick, J.; Mencik, C.; McLaren, C.; Young, C.; Mashford, P.

    2001-01-01

    Diagnostic reference levels for general paediatric radiology have been established in terms of delivered exposure parameters rather than skin dose or dose-area product. With supporting measurements from equipment quality assurance and assumptions of standard patient sizes it was possible to derive reference levels in terms of entrance surface dose. This allowed comparison to be made with other published data. The reference levels for common examinations are presented for different age bands. There is a notable variation with patient age for some examinations which is not apparent in other published data. (author)

  10. Reappraisal of the reference dose distribution in the UNSCEAR 1977 report

    International Nuclear Information System (INIS)

    Kumazawa, Shigeru

    2008-01-01

    This paper provides the update of the reference dose distribution proposed by G.A.M. Web and D. Beninson in Annex E to the UNSCEAR 1977 Report. To demonstrate compliance with regulatory obligations regarding doses to individuals, they defined it with the following properties: 1) The distribution of annual doses is log-normal; 2) The mean of the annual dose distribution is 5 m Gy (10% of the ICRP 1977 dose limit); 3) The proportion of workers exceeding 50 m Gy is 0.1%. The concept of the reference dose distribution is still important to understand the inherent variation of individual doses to workers controlled by source-related and individual-related efforts of best dose reduction. In the commercial nuclear power plant, the dose distribution becomes the more apart from the log-normal due to the stronger ALARA efforts and the revised dose limits. The monitored workers show about 1 m Sv of annual mean and far less than 0.1% of workers above 20 m Sv. The updated models of dose distribution consist of log-normal (no feedback on dose X) ln(X)∼N(μ,σ 2 ), hybrid log-normal (feedback on higher X by ρ) hyb(ρX)=ρX+ln(ρX)∼N(μ,σ 2 ), hybrid S B (feedback on higher dose quotient X/(D-X) not close to D by ρ) hyb[ρX/(D.X)]∼N(μ,σ 2 ) and Johnson's S B (limit to D) ln[X/(D-X)]∼N(μ,σ 2 ). These models afford interpreting the degree of dose control including dose constraint/limit to the reference distribution. Some of distributions are examined to characterize the variation of doses to members of the public with uncertainty. (author)

  11. Remarks on reporting and recording consistent with the ICRU Reference Dose

    Directory of Open Access Journals (Sweden)

    Gainey Mark

    2009-10-01

    Full Text Available Abstract Background ICRU 50/62 provides a framework to facilitate the reporting of external beam radiotherapy treatments from different institutions. A predominant role is played by points that represent "the PTV dose". However, for new techniques like Intensity Modulated Radiotherapy (IMRT - especially step and shoot IMRT - it is difficult to define a point whose dose can be called "characteristic" of the PTV dose distribution. Therefore different volume based methods of reporting of the prescribed dose are in use worldwide. Several of them were compared regarding their usability for IMRT and compatibility with the ICRU Reference Point dose for conformal radiotherapy (CRT in this study. Methods The dose distributions of 45 arbitrarily chosen volumes treated by CRT plans and 57 volumes treated by IMRT plans were used for comparison. Some of the IMRT methods distinguish the planning target volume (PTV and its central part PTVx (PTV minus a margin region of × mm. The reporting of dose prescriptions based on mean and median doses together with the dose to 95% of the considered volume (D95 were compared with each other and in respect of a prescription report with the aid of one or several possible ICRU Reference Points. The correlation between all methods was determined using the standard deviation of the ratio of all possible pairs of prescription reports. In addition the effects of boluses and the characteristics of simultaneous integrated boosts (SIB were examined. Results Two types of methods result in a high degree of consistency with the hitherto valid ICRU dose reporting concept: the median dose of the PTV and the mean dose to the central part of the PTV (PTVx. The latter is similar to the CTV, if no nested PTVs are used and no patient model surfaces are involved. A reporting of dose prescription using the CTV mean dose tends to overestimate the plateau doses of the lower dose plateaus of SIB plans. PTVx provides the possibility to approach

  12. Remarks on reporting and recording consistent with the ICRU Reference Dose

    International Nuclear Information System (INIS)

    Bratengeier, Klaus; Oechsner, Markus; Gainey, Mark; Flentje, Michael

    2009-01-01

    ICRU 50/62 provides a framework to facilitate the reporting of external beam radiotherapy treatments from different institutions. A predominant role is played by points that represent 'the PTV dose'. However, for new techniques like Intensity Modulated Radiotherapy (IMRT) - especially step and shoot IMRT - it is difficult to define a point whose dose can be called 'characteristic' of the PTV dose distribution. Therefore different volume based methods of reporting of the prescribed dose are in use worldwide. Several of them were compared regarding their usability for IMRT and compatibility with the ICRU Reference Point dose for conformal radiotherapy (CRT) in this study. The dose distributions of 45 arbitrarily chosen volumes treated by CRT plans and 57 volumes treated by IMRT plans were used for comparison. Some of the IMRT methods distinguish the planning target volume (PTV) and its central part PTV x (PTV minus a margin region of × mm). The reporting of dose prescriptions based on mean and median doses together with the dose to 95% of the considered volume (D 95 ) were compared with each other and in respect of a prescription report with the aid of one or several possible ICRU Reference Points. The correlation between all methods was determined using the standard deviation of the ratio of all possible pairs of prescription reports. In addition the effects of boluses and the characteristics of simultaneous integrated boosts (SIB) were examined. Two types of methods result in a high degree of consistency with the hitherto valid ICRU dose reporting concept: the median dose of the PTV and the mean dose to the central part of the PTV (PTV x ). The latter is similar to the CTV, if no nested PTVs are used and no patient model surfaces are involved. A reporting of dose prescription using the CTV mean dose tends to overestimate the plateau doses of the lower dose plateaus of SIB plans. PTV x provides the possibility to approach biological effects

  13. Reference dose levels for dental panoramic radiography in Gwangju (South Korea)

    International Nuclear Information System (INIS)

    Lee, J. S.; Kim, Y. H.; Yoon, S. J.; Kang, B. C.

    2010-01-01

    This study assessed the reference dose levels for dental panoramic radiography in Gwangju city (South Korea) based on the dose width product (DWP) and compared them with those already established elsewhere. A total of 44 panoramic dental radiographic sets (36 digital and 8 analogue panoramic sets) in 41 dental clinics in Gwangju city were chosen. The third quartile DWP was determined from 429 surface dose measurements of the adult surface dose in panoramic dental radiography. The third quartile DWP for panoramic radiography was 60.1 mGy mm. The proposed DWP reference levels of 60.1 mGy mm were less than or equal to those previously reported in other countries, such as Italy and UK, and acceptable for panoramic radiography in Gwangju (KR). (authors)

  14. A conceptual framework for managing radiation dose to patients in diagnostic radiology using reference dose levels

    International Nuclear Information System (INIS)

    Almen, Anja; Baath, Magnus

    2016-01-01

    The overall aim of the present work was to develop a conceptual framework for managing radiation dose in diagnostic radiology with the intention to support optimisation. An optimisation process was first derived. The framework for managing radiation dose, based on the derived optimisation process, was then outlined. The outset of the optimisation process is four stages: providing equipment, establishing methodology, performing examinations and ensuring quality. The optimisation process comprises a series of activities and actions at these stages. The current system of diagnostic reference levels is an activity in the last stage, ensuring quality. The system becomes a reactive activity only to a certain extent engaging the core activity in the radiology department, performing examinations. Three reference dose levels-possible, expected and established-were assigned to the three stages in the optimisation process, excluding ensuring quality. A reasonably achievable dose range is also derived, indicating an acceptable deviation from the established dose level. A reasonable radiation dose for a single patient is within this range. The suggested framework for managing radiation dose should be regarded as one part of the optimisation process. The optimisation process constitutes a variety of complementary activities, where managing radiation dose is only one part. This emphasises the need to take a holistic approach integrating the optimisation process in different clinical activities. (authors)

  15. Reference dose levels for dental panoramic radiography in Anyang City

    International Nuclear Information System (INIS)

    Han, Mi Ra; Kang, Byung Cheol; Yoon, Suk Ja; Lee, Jae Seo; Kim, Young Hee

    2009-01-01

    To measure dose-width product (DWP) values used for dental panoramic radiography in Anyang city, Korea. Thirty-six panoramic dental radiographic sets (17 analogue panoramic sets and 19 digital panoramic sets) in 36 dental clinics in Anyang city were included in the study. Each patient's panoramic exposure parameters were simulated and the panoramic radiation doses were measured at the secondary collimator using a Mult-O-Meter (Unfors Instruments, Billdal, Sweden) at each dental clinic during 2006. The third quartile DWP was determined from 310 surface dose measurements on adult. The third quartile DWP for adult panoramic radiograph was 106.7 mGy mm. For analogue and digital panoramic radiograph, 3/4 DWP were 116.8 mGy mm and 72 mGy mm respectively. The overall third quartile DWP of panoramic radiography was 106.7 mGy mm. The measured 3/4 DWPs were higher than the 3/4 DWP of 65 mGy mm recommended by NRPB. Dentists who are operating above the reference dose should lower their panoramic exposure doses below the recommended reference value by changing the exposure parameters and/or their panoramic equipment.

  16. A CONCEPTUAL FRAMEWORK FOR MANAGING RADIATION DOSE TO PATIENTS IN DIAGNOSTIC RADIOLOGY USING REFERENCE DOSE LEVELS.

    Science.gov (United States)

    Almén, Anja; Båth, Magnus

    2016-06-01

    The overall aim of the present work was to develop a conceptual framework for managing radiation dose in diagnostic radiology with the intention to support optimisation. An optimisation process was first derived. The framework for managing radiation dose, based on the derived optimisation process, was then outlined. The outset of the optimisation process is four stages: providing equipment, establishing methodology, performing examinations and ensuring quality. The optimisation process comprises a series of activities and actions at these stages. The current system of diagnostic reference levels is an activity in the last stage, ensuring quality. The system becomes a reactive activity only to a certain extent engaging the core activity in the radiology department, performing examinations. Three reference dose levels-possible, expected and established-were assigned to the three stages in the optimisation process, excluding ensuring quality. A reasonably achievable dose range is also derived, indicating an acceptable deviation from the established dose level. A reasonable radiation dose for a single patient is within this range. The suggested framework for managing radiation dose should be regarded as one part of the optimisation process. The optimisation process constitutes a variety of complementary activities, where managing radiation dose is only one part. This emphasises the need to take a holistic approach integrating the optimisation process in different clinical activities. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Data base of dose coefficients called ecrin-V1-internet reference handbook; Base de donnees de coefficients de dose ecrin-V1-internet manuel de reference

    Energy Technology Data Exchange (ETDEWEB)

    Perrin, M.L

    2003-07-01

    The objective of this data base is to dispose on a only computer medium the values of radiation doses allowing to guarantee the tracing and the coherence of radiation doses received by man. These data are usable to evaluate the risks in the frame of studies or expertise. They include the doses coming from external irradiations, internal contamination by inhalation or ingestion and receive by workers or public. The definitions and reference values come from international publications (the list is given). (N.C.)

  18. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio

    International Nuclear Information System (INIS)

    MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.

    2000-01-01

    This study investigated the influence of dwell time optimizations on dose uniformity characterized by dose values in dose points and dose non-uniformity ratio (DNR) and analyzed which implant parameters have influence on the DNR. Double-plane breast implants with catheters arranged in triangular pattern were used for the calculations. At a typical breast implant, dose values in dose reference points inside the target volume and volumes enclosed by given isodose surfaces were calculated and compared for non-optimized and optimized implants. The same 6-cm treatment length was used for the comparisons. Using different optimizations plots of dose non-uniformity ratio as a function of catheter separation, source step size, number of catheters, length of active sections were drawn and the minimum DNR values were determined. Optimization resulted in less variation in dose values over dose points through the whole volume and in the central plane only compared to the non-optimized case. At implant configurations consisting of seven catheters with 15-mm separation, 5-mm source step size and various active lengths adapted according to the type of optimization, the no optimization, geometrical (volume mode) and dose point (on dose points and geometry) optimization resulted in similar treatment volumes, but an increased high dose volume was observed due to the optimization. The dose non-uniformity ratio always had the minimum at average dose over dose normalization points, defined in the midpoints between the catheters through the implant volume. The minimum value of DNR depended on catheter separation, source step size, active length and number of catheters. The optimization had only a small influence on DNR. In addition to the reference points in the central plane only, dose points positioned in the whole implant volume can be used for evaluating the dose uniformity of interstitial implants. The dose optimization increases not only the dose uniformity within the implant but

  19. Establishment of Reference Doses for residues of allergenic foods: Report of the VITAL Expert Panel

    NARCIS (Netherlands)

    Taylor, S.L.; Baumert, J.L.; Kruizinga, A.G.; Remington, B.C.; Crevel, R.W.R.; Brooke-Taylor, S.; Allen, K.J.; Houben, G.

    2014-01-01

    In 2011, an expert panel was assembled to establish appropriate Reference Doses for allergenic food residues as a part of the VITAL (Voluntary Incidental Trace Allergen Labeling) program of The Allergen Bureau of Australia & New Zealand (ABA). These Reference Doses would guide advisory labeling

  20. Internal Dose Conversion Coefficients of Domestic Reference Animal and Plants for Dose Assessment of Non-human Species

    International Nuclear Information System (INIS)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Choi, Yong Ho

    2009-01-01

    Traditionally, radiation protection has been focused on a radiation exposure of human beings. In the international radiation protection community, one of the recent key issues is to establish the methodology for assessing the radiological impact of an ionizing radiation on non-human species for an environmental protection. To assess the radiological impact to non-human species dose conversion coefficients are essential. This paper describes the methodology to calculate the internal dose conversion coefficient for non-human species and presents calculated internal dose conversion coefficients of 25 radionuclides for 8 domestic reference animal and plants

  1. EMP Attachment 3 DOE-SC PNNL Site Dose Assessment Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Snyder, Sandra F.

    2011-12-21

    This Dose Assessment Guidance (DAG) describes methods to use to determine the Maximally-Exposed Individual (MEI) location and to estimate dose impact to that individual under the U.S. Department of Energy Office of Science (DOE-SC) Pacific Northwest National Laboratory (PNNL) Site Environmental Monitoring Plan (EMP). This guidance applies to public dose from radioactive material releases to the air from PNNL Site operations. This document is an attachment to the Pacific Northwest National Laboratory (PNNL) Environmental Monitoring Plan (EMP) and describes dose assessment guidance for radiological air emissions. The impact of radiological air emissions from the U.S. Department of Energy Office of Science (DOE-SC) PNNL Site is indicated by dose estimates to a maximally exposed member of the public, referred to as the maximally exposed individual (MEI). Reporting requirements associated with dose to members of the public from radiological air emissions are in 40 CFR Part 61.94, WAC 246-247-080, and DOE Order 458.1. The DOE Order and state standards for dose from radioactive air emissions are consistent with U.S. Environmental Protection Agency (EPA) dose standards in 40 CFR 61.92 (i.e., 10 mrem/yr to a MEI). Despite the fact that the current Contract Requirements Document (CRD) for the DOE-SC PNNL Site operations does not include the requirement to meet DOE CRD 458.1, paragraph 2.b, public dose limits, the DOE dose limits would be met when EPA limits are met.

  2. Studies on the establishment of maximum permissible exposure dose for reference Korean

    International Nuclear Information System (INIS)

    Kim, Y.J.; Lee, K.S.; Chun, K.C.; Kim, C.B.; Chung, K.H.; Kim, S.L.; Kim, M.J.

    1981-01-01

    In order to establish the Reference Korean and maximum permissible exposure dose of Reference Korean, for the first year a total of 9,758 males and 7,019 females were surveyed for the height, weight, a body surface area, and a total of 879 individuals of 180 households located in different 30 localities were analyzed for food consumption and a total of radioactive substances (β-ray) contained in food per capita per day. In this report the external and internal exposure dose were also estimated on the basis of data mostly published in other country as well as in Korea in part

  3. A reference dosimetric system for dose interval of radiotherapy based on alanine/RPE

    International Nuclear Information System (INIS)

    Rodrigues Junior, Orlando; Galante, Ocimar L.; Campos, Leticia L.

    2001-01-01

    This work describes the development of a reference dosimetric system based on alanine/EPR for radiotherapy dose levels. Currently the IPEN is concluding a similar system for the dose range used for irradiation of products, 10-10 5 Gy. The objective of this work is to present the efforts towards to improve the measure accuracy for doses in the range between 1-10 Gy. This system could be used as reference by radiotherapy services, as much in the quality control of the equipment, as for routine accompaniment of more complex handling where the total doses can reach some grays. The system uses alanine as detector and electronic paramagnetic resonance - EPR as measure technique. To reach accuracy better than 5% mathematical studies on the best optimization of the EPR spectrometer parameters and methods for the handling of the EPR sign are discussed. (author)

  4. Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures

    International Nuclear Information System (INIS)

    Endo, Akira; Petoussi-Henss, Nina; Zankl, Maria; Schlattl, Helmut; Bolch, Wesley E.; Eckerman, Keith F.; Hertel, Nolan E.; Hunt, John G.; Pelliccioni, Maurizio; Menzel, Hans-Georg

    2014-01-01

    This paper reviews the ICRP Publications 110 and 116 describing the reference computational phantoms and dose conversion coefficients for external exposures. The International Commission on Radiological Protection (ICRP) in its 2007 Recommendations made several revisions to the methods of calculation of the protection quantities. In order to implement these recommendations, the DOCAL task group of the ICRP developed computational phantoms representing the reference adult male and female and then calculated a set of dose conversion coefficients for various types of idealised external exposures. This paper focuses on the dose conversion coefficients for neutrons and investigates their relationship with the conversion coefficients of the protection and operational quantities of ICRP Publication 74. Contributing factors to the differences between these sets of conversion coefficients are discussed in terms of the changes in phantoms employed and the radiation and tissue weighting factors. This paper briefly reviews the reference computational phantoms and dose conversion coefficients for external exposures that were published jointly by ICRP and ICRU. Both these publications appeared as a consequence of the ICRP 2007 Recommendations; to implement these recommendations, the ICRP has developed reference computational phantoms representing the adult male and female. These phantoms are used to calculate reference dose conversion coefficients for external and internal sources. Using the reference phantoms and methodology consistent with the 2007 Recommendations, dose conversion coefficients for both effective doses and organ-absorbed doses for various types of idealised external exposures have been calculated. These data sets supersede the existing ICRP/ICRU data sets and expand the particle types and energy ranges. For neutrons, the new effective dose conversion coefficients become smaller compared with those in ICRP74, for energies below hundreds of keV. This is mainly

  5. The need for national diagnostic reference levels: entrance surface dose measurement in intraoral radiography

    International Nuclear Information System (INIS)

    Mortazavi, S. M. J.; Shareghi, A.; Kavousi, A.; Ghiassi-Nejad, M.; Jafari-Zadeh, M.; Nazeri, F.; Mozdarani, H.

    2004-01-01

    Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection recommendations, the selection of a diagnostic reference level should be specific to a country or region. Critical organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low as reasonably achievable. To assist the development of DRLs for intraoral radiography, a National Radiation Protection Department-sponsored pilot study was carried out. Materials and methods: thermoluminescent dosimetry is widely acknowledged to be the recommended method for measuring entrance surface doses. In this study, entrance surface doses was measured using LiF thermoluminescent dosimeters on the skin (either mandibular or maxillary arcs) of 40 patients. Three thermoluminescent dosimetry chips were placed on the skin of each patient. The doses were averaged for each radiography and mean entrance surface doses of all patients calculated. Results: the mean ±SD entrance surface dose at the center of the beam on the patient's skin in intraoral radiography was 1.173 ±0.606 mGy (ranged from 0.01 o 0.40 m Gy). The mean entrance surface doses for male and female patients were 1.380± 0.823, and 1.004± 0.258 respectively. No statistically significant difference was found between these means. Despite its necessity , in national level , there is no published data on the diagnostic reference levels for intraoral radiography. However, the results obtained in this study are lower than those reported by investigators in other countries. Conclusion: in IR Iran , due to lack of large scale studies, no diagnostic reference levels have been set for X-ray diagnostic procedures. Due to lack of national diagnostic reference levels, it is not possible to clarify whether in intraoral radiographies any dose reduction techniques are needed. We intend to perform similar nationwide studies to set the

  6. Comparison of the COMRADEX-IV and AIRDOS-EPA methodologies for estimating the radiation dose to man from radionuclide releases to the atmosphere

    International Nuclear Information System (INIS)

    Miller, C.W.; Hoffman, F.O.; Dunning, D.E. Jr.

    1981-01-01

    This report presents a comparison between two computerized methodologies for estimating the radiation dose to man from radionuclide releases to the atmosphere. The COMRADEX-IV code was designed to provide a means of assessing potential radiological consequences from postulated power reactor accidents. The AIRDOS-EPA code was developed primarily to assess routine radionuclide releases from nuclear facilities. Although a number of different calculations are performed by these codes, three calculations are in common - atmospheric dispersion, estimation of internal dose from inhalation, and estimation of external dose from immersion in air containing gamma emitting radionuclides. The models used in these calculations were examined and found, in general, to be the same. Most differences in the doses calculated by the two codes are due to differences in values chosen for input parameters and not due to model differences. A sample problem is presented for illustration

  7. Dose area product measurement for diagnostic reference levels and analysis of patient dose in dental radiography

    International Nuclear Information System (INIS)

    Han, S.; Lee, B.; Shin, G.; Choi, J.; Kim, J.; Park, C.; Park, H.; Lee, K.; Kim, Y.

    2008-01-01

    In this study, diagnostic reference levels (DRLs) were suggested and patient doses were analysed through the dose-area product value in dental radiography. In intraoral radiography, at three sites, i.e. molar, premolar and incisor on the maxilla and acquired third quartile values: 55.5, 46 and 36.5 mGy cm 2 , respectively, were measured. In panoramic, cephalo-metric and cone beam computed tomography, the values were 120.3, 146 and 3203 mGy cm 2 (16 x 18 cm), respectively. It has been shown that, in intraoral radiography, the patient dose changes proportionally to the value of mA s, but the change in extra-oral radiography in response to mA s could not be confirmed. The authors could confirm, however, the difference in dose according to the manufacturer in all dental radiography examinations, except for panoramic radiography. Depending on the size of hospital, there were some differences in patient dose in intraoral radiography, but no difference in patient dose in extra-oral radiography. (authors)

  8. Absorbed Internal Dose Conversion Coefficients for Domestic Reference Animals and Plant

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Choi, Yong Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-02-15

    This paper describes the methodology of calculating the internal dose conversion coefficient in order to assess the radiological impact on non-human species. This paper also presents the internal dose conversion coefficients of 25 radionuclides ({sup 3}H, {sup 7}Be, {sup 14}C, {sup 40}K, {sup 51}Cr, {sup 54}Mn, {sup 59}Fe, {sup 58}Co, {sup 60}Co, {sup 65}Zn, {sup 90}Sr, '9{sup 5}Zr, {sup 95}Nb, {sup 99}Tc, {sup 106}Ru, {sup 129}I, {sup 131}I, {sup 136}Cs, {sup 137}Cs, {sup 140}Ba, {sup 140}La, {sup 144}Ce, {sup 238}U, {sup 239}Pu, {sup 240}Pu) for domestic seven reference animals (roe deer, rat, frog, snake, Chinese minnow, bee, and earthworm) and one reference plant (pine tree). The uniform isotropic model was applied in order to calculate the internal dose conversion coefficients. The calculated internal dose conversion coefficient (muGyd{sup -1} per Bqkg{sup -1}) ranged from 10{sup -6} to 10{sup -2} according to the type of radionuclides and organisms studied. It turns out that the internal does conversion coefficient was higher for alpha radionuclides, such as {sup 238}U, {sup 239}Pu, and {sup 240}Pu, and for large organisms, such as roe deer and pine tree. The internal dose conversion coefficients of {sup 239}Pu, {sup 240}Pu, {sup 238}U, {sup 14}C, {sup 3}H and {sup 99}Tc were independent of the organism

  9. Data base of dose coefficients called ecrin-V1-internet reference handbook

    International Nuclear Information System (INIS)

    Perrin, M.L.

    2003-07-01

    The objective of this data base is to dispose on a only computer medium the values of radiation doses allowing to guarantee the tracing and the coherence of radiation doses received by man. These data are usable to evaluate the risks in the frame of studies or expertise. They include the doses coming from external irradiations, internal contamination by inhalation or ingestion and receive by workers or public. The definitions and reference values come from international publications (the list is given). (N.C.)

  10. The true bladder dose: on average thrice higher than the ICRU reference

    International Nuclear Information System (INIS)

    Barillot, I.; Horiot, J.C.; Maingon, P.; Bone-Lepinoy, M.C.; D'Hombres, A.; Comte, J.; Delignette, A.; Feutray, S.; Vaillant, D.

    1996-01-01

    The aim of this study is to compare ICRU dose to doses at the bladder base located from ultrasonography measurements. Since 1990, the dose delivered to the bladder during utero-vaginal brachytherapy was systematically calculated at 3 or 4 points representative of bladder base determined with ultrasonography. The ICRU Reference Dose (IRD) from films, the Maximum Dose (Dmax), the Mean Dose (Dmean) representative of the dose received by a large area of bladder mucosa, the Reference Dose Rate (RDR) and the Mean Dose Rate (MDR) were recorded. Material: from 1990 to 1994, 198 measurements were performed in 152 patients. 98 patients were treated for cervix carcinomas, 54 for endometrial carcinomas. Methods: Bladder complications were classified using French Italian Syllabus. The influence of doses and dose rates on complications were tested using non parametric t test. Results: On average IRD is 21 Gy +/- 12 Gy, Dmax is 51Gy +/- 21Gy, Dmean is 40 Gy +/16 Gy. On average Dmax is thrice higher than IRD and Dmean twice higher than IRD. The same results are obtained for cervix and endometrium. Comparisons on dose rates were also performed: MDR is on average twice higher than RDR (RDR 48 cGy/h vs MDR 88 cGy/h). The five observed complications consist of incontinence only (3 G1, 1G2, 1G3). They are only statistically correlated with RDR p=0.01 (46 cGy/h in patients without complications vs 74 cGy/h in patients with complications). However the full responsibility of RT remains doubtful and should be shared with surgery in all cases. In summary: Bladder mucosa seems to tolerate well much higher doses than previous recorded without increased risk of severe sequelae. However this finding is probably explained by our efforts to spare most of bladder mucosa by 1 deg. ) customised external irradiation therapy (4 fields, full bladder) 2 deg. ) reproduction of physiologic bladder filling during brachytherapy by intermittent clamping of the Foley catheter

  11. Bioequivalence of fixed-dose combination RIN®-150 to each reference drug in loose combination.

    Science.gov (United States)

    Wang, H F; Wang, R; O'Gorman, M; Crownover, P; Damle, B

    2015-03-01

    RIN(®)-150 is a fixed-dose combination (FDC) tablet containing rifampicin (RMP, 150 mg) and isoniazid (INH, 75 mg) developed for the treatment of tuberculosis. This study was conducted at a single center: the Pfizer Clinical Research Unit in Singapore. To demonstrate bioequivalence of each drug component between RIN-150 and individual products in a loose combination. This was a randomized, open-label, single-dose, two-way crossover study. Subjects received single doses of RIN-150 or two individual reference products under fasting conditions in a crossover fashion, with at least 7 days washout between doses. The primary measures for comparison were peak plasma concentration (Cmax) and the area under plasma concentration-time curve (AUC). Of 28 subjects enrolled, 26 completed the study. The adjusted geometric mean ratios of Cmax and AUClast between the FDC and single-drug references and 90% confidence intervals were respectively 91.63% (90%CI 83.13-101.01) and 95.45% (90%CI 92.07-98.94) for RMP, and 107.58% (90%CI 96.07-120.47) and 103.45% (90%CI 99.33-107.75) for INH. Both formulations were generally well tolerated in this study. The RIN-150 FDC tablet formulation is bioequivalent to the two single-drug references for RMP and INH at equivalent doses.

  12. Patient dose with quality image under diagnostic reference levels

    International Nuclear Information System (INIS)

    Akula, Suresh Kumar; Singh, Gurvinder; Chougule, Arun

    2016-01-01

    Need to set Diagnostic Reference Level (DRL) for locations for all diagnostic procedures in local as compared to National. The review of DRL's should compare local with national or referenced averages and a note made of any significant variances to these averages and the justification for it. To survey and asses radiation doses to patient and reduce the redundancy in patient imaging to maintain DRLs

  13. Dose evaluation and establishment of reference levels in activity for nuclear medicine

    International Nuclear Information System (INIS)

    Ribeiro, Julio Cesar de Souza

    2017-01-01

    The International Commission on Radiation Protection (ICRP) has emphasized the importance of accurately determining the mean dose levels, or administered activity, received by the patients for each medical procedure that uses ionizing radiation. However, the number of bibliographic references addressing the need to know and optimize these levels is insufficient, or rather limited, which may lead to non-standardizes techniques, a lack of exposures control, and also the increase of associated radiological risks of these procedures. In this context, a software in Visual Basic® of Microsoft© language was developed whose function is to elaborate a method of obtaining the Reference Levels in Activity (RLA) for nuclear medicine patients by determining the third quartile of the examinations carried out. The program also allows obtaining absorbed dose values in critical organs based on patient specificities as age, sex and Body Mass Index (BMI) in order to evaluate the risk involved in each procedure. The main nuclear medicine diagnostic procedures were evaluated through the database of two public hospitals and a private clinic, obtaining the NRAs of each facility, where the software was validated by comparison with the traditionally accepted calculation methods. Due to the results obtained in each installation, in addition to NRA determination, gaps in treatment capacities and unjustified dose variations for the same procedure were identified, indicating the need for optimization. Thus, the developed program is able to provide the estimated values of effective and absorbed doses involved in each procedure, for each patient, providing reference values for nuclear medicine field, not available in the national scenario so far. (author)

  14. EPA scientists develop Federal Reference & Equivalent Methods for measuring key air pollutants

    Science.gov (United States)

    EPA operates a nationwide air monitoring network to measure six primary air pollutants: carbon monoxide, lead, sulfur dioxide, ozone, nitrogen dioxide, and particulate matter as part of its mission to protect human health and the environment.

  15. A system for environmental protection. Reference dose models for fauna and flora

    International Nuclear Information System (INIS)

    Pentreath, R.J.; Woodhead, D.S.

    2000-01-01

    Ideas have already been published on how the current problems relating to environmental protection could be explicitly addressed. One of the basic cornerstones of the proposed system is that of the use of reference dose models for fauna and flora, in a manner analogous to those used for the human species. The concept is that, for a number of both aquatic and terrestrial fauna and flora types, 'reference' dose models, and dose per unit (internal and external) exposure tables, could be compiled. These would then be used to draw broad conclusions on the likely effects for such organisms in relation to three broad environment end points of concern: life shortening; impairment of reproductive capacity; and scorable, cytogenetic damage. The level of complexity of the dose models needs to be commensurate with the morphological complexity of the modelled organism, its size, and the data bases which are either available or could be reasonably obtained. The most basic models considered are either solid ellipsoids or spheres, with fixed dimensions. Secondary models contain internal, but relatively simple geometric features representative of those key organs or tissues for which more precise estimates of dose are required. Their level of complexity is also a function of different internal and external sources of radiation, and expected differences in radiosensitivities. Tertiary models -of greater complexity- are only considered to be of value for higher vertebrates. The potential derivation and use of all three sets of models is briefly discussed. (author)

  16. Reference dosimetry of proton pencil beams based on dose-area product: a proof of concept.

    Science.gov (United States)

    Gomà, Carles; Safai, Sairos; Vörös, Sándor

    2017-06-21

    This paper describes a novel approach to the reference dosimetry of proton pencil beams based on dose-area product ([Formula: see text]). It depicts the calibration of a large-diameter plane-parallel ionization chamber in terms of dose-area product in a 60 Co beam, the Monte Carlo calculation of beam quality correction factors-in terms of dose-area product-in proton beams, the Monte Carlo calculation of nuclear halo correction factors, and the experimental determination of [Formula: see text] of a single proton pencil beam. This new approach to reference dosimetry proves to be feasible, as it yields [Formula: see text] values in agreement with the standard and well-established approach of determining the absorbed dose to water at the centre of a broad homogeneous field generated by the superposition of regularly-spaced proton pencil beams.

  17. Dose limits, constraints, reference levels. What does it mean for radiation protection?

    International Nuclear Information System (INIS)

    Breckow, J.

    2016-01-01

    The established concept of radiation protection with its basic principles justification, optimization, and limitation has proved its value and is going to be continued. In its deeper meaning, however, the concept is rather subtle and complex. Furthermore, in some aspects there remain some breaches or inconsistencies. This is just true for the terms dose limit, reference lever, and constraint that are tightly associated with the radiation protection principles. In order to guarantee the ability of radiation protection in whole extent, the subtle differences of meaning have to be communicated. There is a permanent need to defend the conceptual function of these terms against deliberate or undeliberate misinterpretations. Reference levels are definitely not the same as dose limits and they may not be misused as such. Any attempt to misinterpret fundamental radiation protection principles for selfish purposes should discouraged vigorously.

  18. Factors affecting quality for beta dose rate measurements using ISO 6980 series I reference sources

    Energy Technology Data Exchange (ETDEWEB)

    Burns, R.E. Jr.; O`Brien, J.M. Jr. [Atlan-Tech, Rosewll, GA (United States)

    1993-12-31

    Atlan-Tech, Inc. has performed several calibrations of ISO 6980 Series 1 reference beta sources over the past two to three years. There were many problems encountered in attempting to compare the results of these calibrations with those from other laboratories, indicating the need for more standardization in the methodology employed for the measurement of the absorbed dose rate from ISO 6980 Series 1 reference beta sources. This document describes some of the problems encountered in attempting to intercompare results of beta dose-rate measurements. It proposes some solutions in an attempt to open a dialogue among facilities using reference beta standards for the purpose of promoting better measurement quality assurance through data intercomparison.

  19. Factors affecting quality for beta dose rate measurements using ISO 6980 series I reference sources

    International Nuclear Information System (INIS)

    Burns, R.E. Jr.; O'Brien, J.M. Jr.

    1993-01-01

    Atlan-Tech, Inc. has performed several calibrations of ISO 6980 Series 1 reference beta sources over the past two to three years. There were many problems encountered in attempting to compare the results of these calibrations with those from other laboratories, indicating the need for more standardization in the methodology employed for the measurement of the absorbed dose rate from ISO 6980 Series 1 reference beta sources. This document describes some of the problems encountered in attempting to intercompare results of beta dose-rate measurements. It proposes some solutions in an attempt to open a dialogue among facilities using reference beta standards for the purpose of promoting better measurement quality assurance through data intercomparison

  20. Modifying EPA radiation risk models based on BEIR VII

    International Nuclear Information System (INIS)

    Pawel, D.; Puskin, J.

    2007-01-01

    This paper summarizes a 'draft White Paper' that provides details on proposed changes in EPA's methodology for estimating radiogenic cancer risks. Many of the changes are based on the contents of a recent National Academy of Sciences (NAS) report (BEIR VII), that addresses cancer and genetic risks from low doses of low-LET radiation. The draft White Paper was prepared for a meeting with the EPA's Science Advisory Board's Radiation Advisory Committee (RAC) in September for seeking advice on the application of BEIR VII and on issues relating to these modifications and expansions. After receiving the Advisory review, we plan to implement the changes by publishing the new methodology in an EPA report, which we expect to submit to the RAC for final review. The revised methodology could then be applied to update the cancer risk coefficients for over 800 radionuclides that are published in EPA's Federal Guidance Report 13. (author)

  1. The role and impact of reference doses on diagnostic radiology, how to use them at the national level?

    International Nuclear Information System (INIS)

    Nikodemova, D.; Horvathova, M.; Karkus, R.

    2003-01-01

    Results of patient dose audits reported in this paper for several types of examinations and various technical units have shown the importance of applications of reference dose levels in radiological practice. On the basis of national surveys slightly lower or higher standard dose reference levels (DRL) values could be justified. Continuing revision of DRL values and their extension to other types of radiographic and fluoroscopic examinations is needed

  2. A comparison of the suitability of patient dosimetry methods for establishing diagnostic dose reference levels and optimisation strategies

    International Nuclear Information System (INIS)

    Gfirtner, Hans; Moores, B. Michael; Stieve, Friedrich E.

    2008-01-01

    For 50 adult patients referred for chest radiography, air kerma at the diaphragm KD, dose area product and entrance skin dose were measured. The air kerma at the diaphragm and the dose area product were determined using Diamentor M4KDK(PTW) which allows measuring air kerma and dose area product simultaneously. For the measurement of entrance skin dose TLDs are used. A 50% variation in dose, incident dose as well as entrance skin dose, was registered for the same patient thickness. The recommendation of ICRP to perform the measurements for DRLs at 'representative patients' and that of the CEC to use 'standard-sized patients' seem to make little sense in the case of chest radiography. It could be demonstrated, that the dose area product is the least appropriate dose quantity for patient measurements and to define dose reference levels. For some radiological examinations like chest, pelvis and lumbar spine the dose area product is even sex dependent. Incident dose and entrance surface dose are of equal quality for patient dose measurements in diagnostic radiography. (author)

  3. 76 FR 9780 - Notification of Deletion of System of Records; EPA Parking Control Office File (EPA-10) and EPA...

    Science.gov (United States)

    2011-02-22

    ... System of Records; EPA Parking Control Office File (EPA-10) and EPA Transit and Guaranteed Ride Home... Environmental Protection Agency (EPA) is deleting the systems of records for EPA Parking Control Office File... through the EPA Internet under the ``Federal Register'' listings at http://www.epa.gov/fedrgstr/ . Dated...

  4. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2012-01-01

    It saddens us deeply to learn of the passing away of Jean-Paul Diss who died suddenly on 7 June 2012 at his home.  A tribute can be read on the GAC-EPA site. * * * * * Information: http://gac-epa.org/ e-mail: gac-epa@gac-epa.org

  5. Evaluation of dose conversion coefficients for external exposure using Taiwanese reference man and woman

    International Nuclear Information System (INIS)

    Chang, S.J.; Hung, S.Y.; Liu, Y.L.; Jiang, S.H.; Wu, J.

    2015-01-01

    Reference man has been widely used for external and internal dose evaluation of radiation protection. The parameters of the mathematical model of organs suggested by the International Commission of Radiological Protection (ICRP) are adopted from the average data of Caucasians. However, the organ masses of Asians are significantly different from the data of Caucasians, leading to potentially dosimetric errors. In this study, a total of 40 volunteers whose heights and weights corresponded to the statistical average of Taiwanese adults were recruited. Magnetic resonance imaging was performed, and T2-weighted images were acquired. The Taiwanese reference man and woman were constructed according to the measured organ masses. The dose conversion coefficients (DCFs) for anterior-posterior (AP), posterior-anterior (PA), right lateral (RLAT) and left lateral (LLAT) irradiation geometries were simulated. For the Taiwanese reference man, the average differences of the DCFs compared with the results of ICRP-74 were 7.6, 5.1 and 11.1 % for 0.1, 1 and 10 MeV photons irradiated in the AP direction. The maximum difference reached 51.7 % for the testes irradiated by 10 MeV photons. The size of the trunk, the volume and the geometric position of organs can cause a significant impact on the DCFs for external exposure of radiation. The constructed Taiwanese reference man and woman can be used in radiation protection to increase the accuracy of dose evaluation for the Taiwanese population. (authors)

  6. Ozone Standard Reference Photometer

    Data.gov (United States)

    Federal Laboratory Consortium — The Standard Reference Photometer (SRP) Program began in the early 1980s as collaboration between NIST and the U.S. Environmental Protection Agency (EPA) to design,...

  7. Establishment of dose reference levels for mammography in Greece

    International Nuclear Information System (INIS)

    Kalathaki, M.; Hourdakis, C.J.; Economides, S.; Tritakis, P.; Manousaridis, G.; Kalyvas, N.; Simantirakis, G.; Kipouros, P.; Kamenopoulou, V.

    2006-01-01

    Full text of publication follows: Diagnostic Reference Levels (D.R.L.) are dose levels established in medical practices for typical x-ray examinations concerning groups of standard size patients or standard phantoms and broadly defined types of equipment. When good and normal practice is performed, these levels are not expected to be exceeded. This work is an attempt to establish for the first time the D.R.L. for mammography in Greece. At present, there are 402 mammographic systems in clinical use all over the country. This study that lasted 3 years (2000-2003), includes 117 of these systems, 85% of which are installed in private and 15% in public sector countrywide. Measurements of entrance surface dose (E.S.D.) were performed as a part of the regular inspections performed by the Licensing and Inspections Department of Greek Atomic Energy Commission on the basis of the laboratories licensing procedure. Moreover, the entire performance of the mammographic units was assessed by quantitative and qualitative measurements of specific parameters. In order to establish the national D.R.L., a standard phantom was used during the quality control of the mammographic units and E.S.D. measurements were performed based on the clinical practice of each laboratory. The D.R.L. for this type of examination was established according to the 75. percentile of the E.S.D. curve and found equal to 7 mGy per single view. The comparison of this value with the one reported by the European Commission (10 mGy per view), indicates that the D.R.L. for mammography is lower in Greece. However, the primary concern of a mammographic examination is to keep breast dose as low as reasonably achievable while providing images with the maximum amount of diagnostic information. The quality of the produced images was therefore assessed for all systems examined, regardless of meeting or exceeding the quality criteria reference surface entrance dose. The results showed that the average total score of the

  8. Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures

    Science.gov (United States)

    Schlattl, H.; Zankl, M.; Petoussi-Henss, N.

    2007-04-01

    A new series of organ equivalent dose conversion coefficients for whole body external photon exposure is presented for a standardized couple of human voxel models, called Rex and Regina. Irradiations from broad parallel beams in antero-posterior, postero-anterior, left- and right-side lateral directions as well as from a 360° rotational source have been performed numerically by the Monte Carlo transport code EGSnrc. Dose conversion coefficients from an isotropically distributed source were computed, too. The voxel models Rex and Regina originating from real patient CT data comply in body and organ dimensions with the currently valid reference values given by the International Commission on Radiological Protection (ICRP) for the average Caucasian man and woman, respectively. While the equivalent dose conversion coefficients of many organs are in quite good agreement with the reference values of ICRP Publication 74, for some organs and certain geometries the discrepancies amount to 30% or more. Differences between the sexes are of the same order with mostly higher dose conversion coefficients in the smaller female model. However, much smaller deviations from the ICRP values are observed for the resulting effective dose conversion coefficients. With the still valid definition for the effective dose (ICRP Publication 60), the greatest change appears in lateral exposures with a decrease in the new models of at most 9%. However, when the modified definition of the effective dose as suggested by an ICRP draft is applied, the largest deviation from the current reference values is obtained in postero-anterior geometry with a reduction of the effective dose conversion coefficient by at most 12%.

  9. Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures

    International Nuclear Information System (INIS)

    Schlattl, H; Zankl, M; Petoussi-Henss, N

    2007-01-01

    A new series of organ equivalent dose conversion coefficients for whole body external photon exposure is presented for a standardized couple of human voxel models, called Rex and Regina. Irradiations from broad parallel beams in antero-posterior, postero-anterior, left- and right-side lateral directions as well as from a 360 deg. rotational source have been performed numerically by the Monte Carlo transport code EGSnrc. Dose conversion coefficients from an isotropically distributed source were computed, too. The voxel models Rex and Regina originating from real patient CT data comply in body and organ dimensions with the currently valid reference values given by the International Commission on Radiological Protection (ICRP) for the average Caucasian man and woman, respectively. While the equivalent dose conversion coefficients of many organs are in quite good agreement with the reference values of ICRP Publication 74, for some organs and certain geometries the discrepancies amount to 30% or more. Differences between the sexes are of the same order with mostly higher dose conversion coefficients in the smaller female model. However, much smaller deviations from the ICRP values are observed for the resulting effective dose conversion coefficients. With the still valid definition for the effective dose (ICRP Publication 60), the greatest change appears in lateral exposures with a decrease in the new models of at most 9%. However, when the modified definition of the effective dose as suggested by an ICRP draft is applied, the largest deviation from the current reference values is obtained in postero-anterior geometry with a reduction of the effective dose conversion coefficient by at most 12%

  10. Dose evaluation and establishment of reference levels in activity for nuclear medicine; Avaliação de dose e estabelecimento de níveis de referência em atividade para a medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Julio Cesar de Souza

    2017-07-01

    The International Commission on Radiation Protection (ICRP) has emphasized the importance of accurately determining the mean dose levels, or administered activity, received by the patients for each medical procedure that uses ionizing radiation. However, the number of bibliographic references addressing the need to know and optimize these levels is insufficient, or rather limited, which may lead to non-standardizes techniques, a lack of exposures control, and also the increase of associated radiological risks of these procedures. In this context, a software in Visual Basic® of Microsoft© language was developed whose function is to elaborate a method of obtaining the Reference Levels in Activity (RLA) for nuclear medicine patients by determining the third quartile of the examinations carried out. The program also allows obtaining absorbed dose values in critical organs based on patient specificities as age, sex and Body Mass Index (BMI) in order to evaluate the risk involved in each procedure. The main nuclear medicine diagnostic procedures were evaluated through the database of two public hospitals and a private clinic, obtaining the NRAs of each facility, where the software was validated by comparison with the traditionally accepted calculation methods. Due to the results obtained in each installation, in addition to NRA determination, gaps in treatment capacities and unjustified dose variations for the same procedure were identified, indicating the need for optimization. Thus, the developed program is able to provide the estimated values of effective and absorbed doses involved in each procedure, for each patient, providing reference values for nuclear medicine field, not available in the national scenario so far. (author)

  11. Organ doses, effective doses, and risk indices in adult CT: Comparison of four types of reference phantoms across different examination protocols

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Yakun; Li Xiang; Paul Segars, W.; Samei, Ehsan [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Carl E. Ravin Advanced Imaging Laboratories, Duke University, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Duke University, Durham, North Carolina 27705 and Department of Radiology, Duke University, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Duke University, Durham, North Carolina 27705 (United States) and Department of Radiology, Duke University, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Duke University, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University, Durham, North Carolina 27705 (United States) and Departments of Physics, Biomedical Engineering, and Electrical and Computer Engineering, Duke University, Durham, North Carolina 27705 (United States)

    2012-06-15

    Purpose: Radiation exposure from computed tomography (CT) to the public has increased the concern among radiation protection professionals. Being able to accurately assess the radiation dose patients receive during CT procedures is a crucial step in the management of CT dose. Currently, various computational anthropomorphic phantoms are used to assess radiation dose by different research groups. It is desirable to better understand how the dose results are affected by different choices of phantoms. In this study, the authors assessed the uncertainties in CT dose and risk estimation associated with different types of computational phantoms for a selected group of representative CT protocols. Methods: Routinely used CT examinations were categorized into ten body and three neurological examination categories. Organ doses, effective doses, risk indices, and conversion coefficients to effective dose and risk index (k and q factors, respectively) were estimated for these examinations for a clinical CT system (LightSpeed VCT, GE Healthcare). Four methods were used, each employing a different type of reference phantoms. The first and second methods employed a Monte Carlo program previously developed and validated in our laboratory. In the first method, the reference male and female extended cardiac-torso (XCAT) phantoms were used, which were initially created from the Visible Human data and later adjusted to match organ masses defined in ICRP publication 89. In the second method, the reference male and female phantoms described in ICRP publication 110 were used, which were initially developed from tomographic data of two patients and later modified to match ICRP 89 organ masses. The third method employed a commercial dosimetry spreadsheet (ImPACT group, London, England) with its own hermaphrodite stylized phantom. In the fourth method, another widely used dosimetry spreadsheet (CT-Expo, Medizinische Hochschule, Hannover, Germany) was employed together with its associated

  12. Organ doses, effective doses, and risk indices in adult CT: Comparison of four types of reference phantoms across different examination protocols

    International Nuclear Information System (INIS)

    Zhang Yakun; Li Xiang; Paul Segars, W.; Samei, Ehsan

    2012-01-01

    Purpose: Radiation exposure from computed tomography (CT) to the public has increased the concern among radiation protection professionals. Being able to accurately assess the radiation dose patients receive during CT procedures is a crucial step in the management of CT dose. Currently, various computational anthropomorphic phantoms are used to assess radiation dose by different research groups. It is desirable to better understand how the dose results are affected by different choices of phantoms. In this study, the authors assessed the uncertainties in CT dose and risk estimation associated with different types of computational phantoms for a selected group of representative CT protocols. Methods: Routinely used CT examinations were categorized into ten body and three neurological examination categories. Organ doses, effective doses, risk indices, and conversion coefficients to effective dose and risk index (k and q factors, respectively) were estimated for these examinations for a clinical CT system (LightSpeed VCT, GE Healthcare). Four methods were used, each employing a different type of reference phantoms. The first and second methods employed a Monte Carlo program previously developed and validated in our laboratory. In the first method, the reference male and female extended cardiac-torso (XCAT) phantoms were used, which were initially created from the Visible Human data and later adjusted to match organ masses defined in ICRP publication 89. In the second method, the reference male and female phantoms described in ICRP publication 110 were used, which were initially developed from tomographic data of two patients and later modified to match ICRP 89 organ masses. The third method employed a commercial dosimetry spreadsheet (ImPACT group, London, England) with its own hermaphrodite stylized phantom. In the fourth method, another widely used dosimetry spreadsheet (CT-Expo, Medizinische Hochschule, Hannover, Germany) was employed together with its associated

  13. Patient dose measurement in common medical X-ray examinations and propose the first local dose reference levels to diagnostic radiology in Iran

    Science.gov (United States)

    Rasuli, Behrouz; Tabari Juybari, Raheleh; Forouzi, Meysam; Ghorbani, Mohammad

    2017-09-01

    Introduction: The main purpose of this study was to investigate patient dose in pelvic and abdomen x-ray examinations. This work also provided the LDRLs (local diagnostic reference levels) in Khuzestan region, southwest of Iran to help establish the NDRLs (national diagnostic reference levels). Methods: Patient doses were assessed from patient's anatomical data and exposure parameters based on the IAEA indirect dosimetry method. With regard to this method, exposure parameters such as tube output, kVp, mAs, FFD and patient anatomical data were used for calculating ESD (entrance skin dose) of patients. This study was conducted on 250 standard patients (50% men and 50% women) at eight high-patient-load imaging centers. Results: The results indicate that mean ESDs for the both pelvic and abdomen examinations were lower than the IAEA and EC reference levels, 2.3 and 3.7 mGy, respectively. Mean applied kVps were 67 and 70 and mean FFDs were 103 and 109, respectively. Tube loadings obtained in this study for pelvic examination were lower than all the corresponding values in the reviewed literature. Likewise, the average annual patient load across all hospitals were more than 37000 patients, i.e. more than 100 patients a day. Conclusions: The authors recommend that DRLs (diagnostic reference levels) obtained in this region, which are the first available data, can be used as local DRLs for pelvic and abdomen procedures. This work also provides that on-the-job training programs for staffs and close cross collaboration between physicists and physicians should be strongly considered.

  14. Hg0 and HgCl2 Reference Gas Standards: ?NIST Traceability ...

    Science.gov (United States)

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the true concentrations of Hg0 and HgCl2 reference gases produced from high quality, NIST-traceable, commercial Hg0 and HgCl2 generators. This presentation will also discuss the availability of HCl and Hg0 compressed reference gas standards as a result of EPA's recently approved Alternative Methods 114 and 118. Gaseous elemental mercury (Hg0) and oxidized mercury (HgCl2) reference standards are integral to the use of mercury continuous emissions monitoring systems (Hg CEMS) for regulatory compliance emissions monitoring. However, a quantitative disparity of approximately 7-10% has been observed between commercial Hg0 and HgCl2 reference gases which currently limits the use of (HgCl2) reference gas standards. Resolving this disparity would enable the expanded use of (HgCl2) reference gas standards for regulatory compliance purposes.

  15. 77 FR 59879 - Idaho: Incorporation by Reference of Approved State Hazardous Waste Management Program

    Science.gov (United States)

    2012-10-01

    ...: Incorporation by Reference of Approved State Hazardous Waste Management Program AGENCY: Environmental Protection... ``Approved State Hazardous Waste Management Programs,'' Idaho's authorized hazardous waste program. The EPA... Federal Register, the EPA is codifying and incorporating by reference the State's hazardous waste program...

  16. Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang Yong; Lee, Byung Young; Lee, Jung Eun; Lee, Hyun Koo; Jung, Seunbg Hwan; Kim, Byung Woo; Kim, Hyeog Ju; Kim, Dong Sup [Radiation Safety Division National Institute of Food and Drug Safety Evaluation, Seoul (Korea, Republic of)

    2009-12-15

    Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60-97 kVp, with the average use being 75 kVp, and the tube current ranged between 8-123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65-100 kVp (average use: 78 kVp) and 70-109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10-100 mAs(average use: 35 mAs) and between 8.9-300 mAs(average use: 64 mAs), respectively. The measurements of

  17. Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea

    International Nuclear Information System (INIS)

    Lee, Kwang Yong; Lee, Byung Young; Lee, Jung Eun; Lee, Hyun Koo; Jung, Seunbg Hwan; Kim, Byung Woo; Kim, Hyeog Ju; Kim, Dong Sup

    2009-01-01

    Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60-97 kVp, with the average use being 75 kVp, and the tube current ranged between 8-123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65-100 kVp (average use: 78 kVp) and 70-109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10-100 mAs(average use: 35 mAs) and between 8.9-300 mAs(average use: 64 mAs), respectively. The measurements of

  18. Guidance document for setting an Acute Reference Dose in Dutch national pesticide evaluations

    NARCIS (Netherlands)

    Raaij MTM van; CSR

    2001-01-01

    This report describes a proposal for the procedures for setting an Acute Reference Dose (ARfD) for pesticides evaluated in the Netherlands. This deals with both evaluations on the national level (on behalf of the Dutch Board for the Authorisation of Pesticides (CTB)) and evaluations at the European

  19. Establishment of national diagnostic reference level for renal doses in nuclear medicine departments at Khartoum-Sudan

    International Nuclear Information System (INIS)

    Alameen, Suhaib; Hamid, Alhadi; Rushdi, M. A. H.

    2016-01-01

    In this work we established a diagnostic reference level (DRL) for patient dose focusing on the investigation of activity to the kidneys during(99mTc-DTPA) kidney scan, selected two department nuclear medicine in main hospitals in Khartoum state. The DRLs is an investigational level used to identify unusually high radiation doses for common diagnostic medical in Nuclear Medicine procedures and suggested action levels above which a facility should review its methods and determine if acceptable image quality can be achieved at lower doses. The high specific activity of 99mTc makes it suitable as a first pass agent, for multiple or sequential studies, 99mTc diethylenetriaminepentaacetic acid (DTPA) is preferred to 99mTc-pertechnetate. Patients who had been prepared for the kidney scan 99mTc- DTPA were divided to three groups. The first group received dose less than 5 mCi, are represent (27.03%) from all patients, second group received dose 5 to 5.5 mCi are represent(66.67%) and the third group received dose from 5.6 to 6.2 mCi are represent (6.31%) from all patients 99mTc-DTPA. And according to the IAEA recommendation for adult doses(5-10mCi) this study show that about 93.1% of the sample examines by dose less than 5.5 mCi. The results presented will serve as a baseline data needed for deriving reference doses for renal examinations for nuclear medicine departments in Sudan.(Author)

  20. Calculation of local skin doses with ICRP adult mesh-type reference computational phantoms

    Science.gov (United States)

    Yeom, Yeon Soo; Han, Haegin; Choi, Chansoo; Nguyen, Thang Tat; Lee, Hanjin; Shin, Bangho; Kim, Chan Hyeong; Han, Min Cheol

    2018-01-01

    Recently, Task Group 103 of the International Commission on Radiological Protection (ICRP) developed new mesh-type reference computational phantoms (MRCPs) for adult males and females in order to address the limitations of the current voxel-type reference phantoms described in ICRP Publication 110 due to their limited voxel resolutions and the nature of the voxel geometry. One of the substantial advantages of the MRCPs over the ICRP-110 reference phantoms is the inclusion of a 50-μm-thick radiosensitive skin basal-cell layer; however, a methodology for calculating the local skin dose (LSD), i.e., the maximum dose to the basal layer averaged over a 1-cm2 area, has yet to be developed. In the present study, a dedicated program for the LSD calculation with the MRCPs was developed based on the mean shift algorithm and the Geant4 Monte Carlo code. The developed program was used to calculate local skin dose coefficients (LSDCs) for electrons and alpha particles, which were then compared with the values given in ICRP Publication 116 that were produced with a simple tissue-equivalent cube model. The results of the present study show that the LSDCs of the MRCPs are generally in good agreement with the ICRP-116 values for alpha particles, but for electrons, significant differences are found at energies higher than 0.15 MeV. The LSDCs of the MRCPs are greater than the ICRP-116 values by as much as 2.7 times at 10 MeV, which is due mainly to the different curvature between realistic MRCPs ( i.e., curved) and the simple cube model ( i.e., flat).

  1. Optimisation of radioprotection of patients in nuclear medicine: assessment of doses for the new ICRP's reference voxelized phantoms

    International Nuclear Information System (INIS)

    Hadid, L.; Blanchardon, E.; Desbree, A.; Makovicka, L.; Zankl, M.

    2010-01-01

    As the ICPR (International Commission on Radiological Protection) decided to adopt voxelized phantoms to emulate a reference adult, the authors report the validation of calculations of the SFAs (specific absorbed fractions) for the new ICPR's reference phantoms. After a presentation of these phantoms, the authors briefly present the OEDIPE software which is used to compute the SAFs and notably the absorbed doses. They discuss the results obtained for the SAFs (for photons and for electrons) and for the doses

  2. The impact of diagnostic reference levels on patient doses from X-ray examinations

    International Nuclear Information System (INIS)

    Leitz, W.; Almen, A.

    2008-01-01

    The aim of this study was to evaluate the effect of diagnostic reference levels (DRL). For this study patient doses for the years 1999 and 2006 were available. Patient doses on a national level for eleven specified X-ray examinations were assessed. For the conventional examinations DRL have been used after the first survey in 1999, for computed tomography no DRL were used and for mammography DRL have been used for more than 20 years. Whereas the patient doses for conventional examinations were 30% lower in 2006 compared to 1999 the doses remained essentially the same for computed tomography and mammography. The widths of the dose distributions had only slightly decreased for conventional examinations and remained the same for computed tomography and mammography. This study has shown that after implementation of DRL a considerable dose reduction can be expected. Practices exceeding DRL will perform remedial actions with the aim to reduce dose, as demonstrated for the conventional examinations. Despite the fact that practices for computed tomography could compare doses with others practices, in the absence of DRL no actions to reduce doses were performed. The margin for further dose reductions in mammography is small due to the long term use of DRL. The impact of DRL on patient doses is changing with time. When introduced large dose reductions can be expected. After long term use DRL will counteract the introduction of new technique with unjustified high patient doses. Despite the merits in terms of dose saving it must be recognized that DRL has its limits - it has to be amended with other radiological protection activities. Other means and measures have to be developed, for example by the authorities, in order to ensure that optimisation is continued even when the patient doses are below the DRL. (author)

  3. Patient doses in CT examinations in Switzerland: Implementation of national diagnostic reference levels

    International Nuclear Information System (INIS)

    Treier, R.; Aroua, A.; Verdun, F. R.; Samara, E.; Stuessi, A.; Trueb, P. R.

    2010-01-01

    Diagnostic reference levels (DRLs) were established for 21 indication-based CT examinations for adults in Switzerland. One hundred and seventy-nine of 225 computed tomography (CT) scanners operated in hospitals and private radiology institutes were audited on-site and patient doses were collected. For each CT scanner, a correction factor was calculated expressing the deviation of the measured weighted computed tomography dose index (CTDI) to the nominal weighted CTDI as displayed on the workstation. Patient doses were corrected by this factor providing a realistic basis for establishing national DRLs. Results showed large variations in doses between different radiology departments in Switzerland, especially for examinations of the petrous bone, pelvis, lower limbs and heart. This indicates that the concept of DRLs has not yet been correctly applied for CT examinations in clinical routine. A close collaboration of all stakeholders is mandatory to assure an effective radiation protection of patients. On-site audits will be intensified to further establish the concept of DRLs in Switzerland. (authors)

  4. Organ doses for reference pediatric and adolescent patients undergoing computed tomography estimated by Monte Carlo simulation

    International Nuclear Information System (INIS)

    Lee, Choonsik; Kim, Kwang Pyo; Long, Daniel J.; Bolch, Wesley E.

    2012-01-01

    Purpose: To establish an organ dose database for pediatric and adolescent reference individuals undergoing computed tomography (CT) examinations by using Monte Carlo simulation. The data will permit rapid estimates of organ and effective doses for patients of different age, gender, examination type, and CT scanner model. Methods: The Monte Carlo simulation model of a Siemens Sensation 16 CT scanner previously published was employed as a base CT scanner model. A set of absorbed doses for 33 organs/tissues normalized to the product of 100 mAs and CTDI vol (mGy/100 mAs mGy) was established by coupling the CT scanner model with age-dependent reference pediatric hybrid phantoms. A series of single axial scans from the top of head to the feet of the phantoms was performed at a slice thickness of 10 mm, and at tube potentials of 80, 100, and 120 kVp. Using the established CTDI vol - and 100 mAs-normalized dose matrix, organ doses for different pediatric phantoms undergoing head, chest, abdomen-pelvis, and chest-abdomen-pelvis (CAP) scans with the Siemens Sensation 16 scanner were estimated and analyzed. The results were then compared with the values obtained from three independent published methods: CT-Expo software, organ dose for abdominal CT scan derived empirically from patient abdominal circumference, and effective dose per dose-length product (DLP). Results: Organ and effective doses were calculated and normalized to 100 mAs and CTDI vol for different CT examinations. At the same technical setting, dose to the organs, which were entirely included in the CT beam coverage, were higher by from 40 to 80% for newborn phantoms compared to those of 15-year phantoms. An increase of tube potential from 80 to 120 kVp resulted in 2.5-2.9-fold greater brain dose for head scans. The results from this study were compared with three different published studies and/or techniques. First, organ doses were compared to those given by CT-Expo which revealed dose differences up to

  5. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2014-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 4 février de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org. * * * * * Carte de membre de l'Association du personnel du CERN Les membres GAC-EPA qui souhaitent recevoir une carte de membre AP en 2014 doivent  en faire la demande par email à secretariat@gac-epa.org, ou par lettre au secrétaire ...

  6. Internal and external dose conversion coefficient for domestic reference animals and plant

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Park, Du Won; Choi, Young Ho

    2009-07-15

    This report presents the internal and external dose conversion coefficients for domestic reference animals and plant, which are essential to assess the radiological impact of an environmental radiation on non-human species. To calculate the dose conversion coefficients, a uniform isotropic model and a Monte Carlo method for a photon transport simulation in environmental media with different densities have been applied for aquatic and terrestrial animals, respectively. In the modeling all the target animals are defined as a simple 3D elliptical shape. To specify the external radiation source it is assumed that aquatic animals are fully immersed in infinite and uniformly contaminated water, and the on-soil animals are living on the surface of a horizontally infinite soil source, and the in-soil organisms are living at the center of a horizontally infinite and uniformly contaminated soil to a depth of 50cm. A set of internal and external dose conversion coefficients for 8 Korean reference animals and plant (rat, roe-deer, frog, snake, Chinese minnow, bee, earthworm, and pine tree) are presented for 25 radionuclides ({sup 3}H, {sup 7}Be, {sup 14}C, {sup 40}K, {sup 51}Cr, {sup 54}Mn, {sup 59}Fe, {sup 58}Co, {sup 60}Co, {sup 65}Zn, {sup 90}Sr, {sup 95}Zr, {sup 95}Nb, {sup 99}Tc, {sup 106}Ru, {sup 129}I, {sup 131}I, {sup 136}Cs, {sup 137}Cs, {sup 140}Ba, {sup 140}La, {sup 144}Ce, {sup 238}U, {sup 239}Pu, and {sup 240}Pu)

  7. Establishment of computed tomography reference dose levels in Onassis Cardiac Surgery Center

    International Nuclear Information System (INIS)

    Tsapaki, V.; Kyrozi, E.; Syrigou, T.; Mastorakou, I.; Kottou, S.

    2001-01-01

    The purpose of the study was to apply European Commission (EC) Reference Dose Levels (RDL) in Computed Tomography (CT) examinations at Onassis Cardiac Surgery Center (OCSC). These are weighted CT Dose Index (CTDI w ) for a single slice and Dose-Length Product (DLP) for a complete examination. During the period 1998-1999, the total number of CT examinations, every type of CT examination, patient related data and technical parameters of the examinations were recorded. The most frequent examinations were chosen for investigation which were the head, chest, abdomen and pelvis. CTDI measurements were performed and CTDI w and DLP were calculated. Third Quartile values of CTDI w were chosen to be 43mGy for head, 8mGy for chest, and 22mGy for abdomen and pelvis examinations. Third quartile values of DLP were chosen to be 740mGycm for head, 370mGycm for chest, 490mGycm for abdomen and 420mGycm for pelvis examination. Results confirm that OCSC follows successfully the proposed RDL for the head, chest, abdomen and pelvis examinations in terms of radiation dose. (author)

  8. 76 FR 26681 - Wisconsin: Incorporation by Reference of Approved State Hazardous Waste Management Program

    Science.gov (United States)

    2011-05-09

    ... of Approved State Hazardous Waste Management Program AGENCY: Environmental Protection Agency (EPA... Hazardous Waste Management Programs,'' Wisconsin's authorized hazardous waste program. EPA will incorporate... that are authorized and that the EPA will enforce under the Solid Waste Disposal Act, commonly referred...

  9. Estimating the population dose from nuclear medicine examinations towards establishing diagnostic reference levels

    International Nuclear Information System (INIS)

    Niksirat, Fatemeh; Monfared, Ali Shabestani; Deevband, Mohammad Reza; Amiri, Mehrangiz; Gholami, Amir

    2016-01-01

    This study conducted a review on nuclear medicine (NM) services in Mazandaran Province with a view to establish adult diagnostic reference levels (DRLs) and provide updated data on population radiation exposure resulting from diagnostic NM procedures. The data were collected from all centers in all cities of Mazandaran Province in the North of Iran from March 2014 to February 2015. The 75 th percentile of the distribution and the average administered activity (AAA) were calculated and the average effective dose per examination, collective effective dose to the population and annual effective dose per capita were estimated using dose conversion factors. The gathered data were analyzed via SPSS (version 18) software using descriptive statistics. Based on the data of this study, the collective effective dose was 95.628 manSv, leading to a mean effective dose of 0.03 mSv per capita. It was also observed that the myocardial perfusion was the most common procedure (50%). The 75 th percentile of the distribution of administered activity (AA) represents the DRL. The AAA and the 75 th percentile of the distribution of AA are slightly higher than DRL of most European countries. Myocardial perfusion is responsible for most of the collective effective dose and it is better to establish national DRLs for myocardial perfusion and review some DRL values through the participation of NM specialists in the future

  10. 76 FR 26616 - Wisconsin: Incorporation by Reference of Approved State Hazardous Waste Management Program

    Science.gov (United States)

    2011-05-09

    ... Reference of Approved State Hazardous Waste Management Program AGENCY: Environmental Protection Agency (EPA... (RCRA) allows EPA to authorize States to operate their hazardous waste management programs in lieu of the Federal program. EPA uses the regulations entitled ``Approved State Hazardous Waste Management...

  11. Patient dose audit of the most frequent radiographic examinations and the proposed local diagnostic reference levels in southwestern Nigeria: Imperative for dose optimisation

    Directory of Open Access Journals (Sweden)

    N.N. Jibiri

    2016-07-01

    Full Text Available Diagnostic reference levels (DRLs is a veritable tool for dose optimisation and patient protection in diagnostic radiology. However, it is essential to have information on the local situation especially in a large hospital with several units or a cluster of healthcare centres within a geographical region with several X-ray units. In the present study, entrance surface doses (ESDs were measured in twelve (12 healthcare centres consisting of 15 radiological units using thermoluminescent dosimeters (TLDs. Seven radiological procedures such as; chest PA, abdomen AP, pelvis AP, lumbar spine AP, skull AP, knee AP, and hand AP frequently carried out in Nigeria were included in the study, and their local diagnostic reference levels (LDRLs were determined. The values of the determined LDRLs were compared with established NDRLs in UK, US, Slovenia, Italy and Brazil. The LDRLs determined in the two groups (healthcare centres studied ranged from 1.78 to 3.01, 2.71 to 2.84, 2.11 to 3.79, 3.93 to 8.79, 1.06 to 1.73 and 1.10 to 1.44 mGy for chest PA, pelvis AP, lumbar spine AP, skull AP, knee AP and hand AP respectively. Large variations were found among the X-ray units studied even within the same centre. Entrance surface doses obtained in pelvis AP and lumbar spine AP in both GROUP A and were found to be lower than the NRPB-HPA 2010 review for UK, while in all other five examinations, value of the measured entrance surface dose (ESD are higher than the doses reported in the UK review. The relative higher doses found in the study are attributable to higher tube load (mAs used and indicative of the need for dose optimisation in Nigerian radiological practice.

  12. Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures

    CERN Document Server

    Endo, A; Zankl, M; Bolch, W E; Eckerman, K F; Hertel, N E; Hunt, J G; Pelliccioni, M; Schlattl, H; Menzel, H-G

    2014-01-01

    This paper reviews the ICRP Publications 110 and 116 describing the reference computational phantoms and dose conversion coefficients for external exposures. The International Commission on Radiological Protection (ICRP) in its 2007 Recommendations made several revisions to the methods of calculation of the protection quantities. In order to implement these recommendations, the DOCAL task group of the ICRP developed computational phantoms representing the reference adult male and female and then calculated a set of dose conversion coefficients for various types of idealised external exposures. This paper focuses on the dose conversion coefficients for neutrons and investigates their relationship with the conversion coefficients of the protection and operational quantities of ICRP Publication 74. Contributing factors to the differences between these sets of conversion coefficients are discussed in terms of the changes in phantoms employed and the radiation and tissue weighting factors.

  13. EPA's criteria development for radioactive waste that is Below Regulatory Concern

    International Nuclear Information System (INIS)

    Holcomb, W.F.; Gruhlke, J.M.

    1987-01-01

    The EPA's program for developing environmental standards for land disposal of low-level radioactive wastes, including a criterion for determining wastes with sufficiently low levels of radioactivity to be considered Below Regulatory Concern (BRC) has completed its risk assessment and cost-effectiveness analyses. The analyses for the BRC criterion included evaluation of general population health risks, maximum annual exposures to critical population groups, and costs of risk reduction. These risk assessments include analyses of 18 surrogate radioactive waste streams, representing both fuel cycle and non-fuel cycle facilities. Less restrictive disposal alternatives typical of those used for municipal garbage disposal, such as sanitary landfills, and situated in diverse demographic settings were used in the analyses. A number of waste types which contribute only small doses or fractions of a health effect over 10,000 years from unregulated disposal were identified. Disposal of such wastes without consideration of their very low radioactivity content results in significant cost savings. 3 references, 1 figure, 4 tables

  14. Effects of Eicosapentaenoic Acid (EPA) and Docosahexaenoic Acid (DHA) on Fetal Pulmonary Circulation: An Experimental Study in Fetal Lambs.

    Science.gov (United States)

    Sharma, Dyuti; Aubry, Estelle; Ouk, Thavarak; Houeijeh, Ali; Houfflin-Debarge, Véronique; Besson, Rémi; Deruelle, Philippe; Storme, Laurent

    2017-07-16

    Background: Persistent pulmonary hypertension of the newborn (PPHN) causes significant morbidity and mortality in neonates. n -3 Poly-unsaturated fatty acids have vasodilatory properties in the perinatal lung. We studied the circulatory effects of eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) in fetal sheep and in fetal pulmonary arterial rings. Methods: At 128 days of gestation, catheters were placed surgically in fetal systemic and pulmonary circulation, and a Doppler probe around the left pulmonary artery (LPA). Pulmonary arterial pressure and LPA flow were measured while infusing EPA or DHA for 120 min to the fetus, to compute pulmonary vascular resistance (PVR). The dose effects of EPA or DHA were studied in vascular rings pre-constricted with serotonin. Rings treated with EPA were separated into three groups: E+ (intact endothelium), E- (endothelium stripped) and LNA E+ (pretreatment of E+ rings with l-nitro-arginine). Results: EPA, but not DHA, induced a significant and prolonged 25% drop in PVR ( n = 8, p DHA resulted in only a mild relaxation at the highest concentration of DHA (300 µM) compared to E+. Conclusions: EPA induces a sustained pulmonary vasodilatation in fetal lambs. This effect is endothelium- and dose-dependent and involves nitric oxide (NO) production. We speculate that EPA supplementation may improve pulmonary circulation in clinical conditions with PPHN.

  15. Model for assessing alpha doses for a Reference Japanese Man

    International Nuclear Information System (INIS)

    Kawamura, Hisao

    1993-01-01

    In view of the development of the nuclear fuel cycle in this country, it is urgently important to establish dose assessment models and related human and environmental parameters for long-lived radionuclides. In the current program, intake and body content of actinides (Pu, Th, U) and related alpha-emitting nuclides (Ra and daughters) have been studied as well as physiological aspects of Reference Japanese Man as the basic model of man for dosimetry. The ultimate object is to examine applicability of the existing models particularly recommended by the ICRP for workers to members of the public. The result of an interlaboratory intercomparison of 239 Pu + 240 Pu determination including our result was published. Alpha-spectrometric determinations of 226 Ra in bone yielded repesentative bone concentration level in Tokyo and Ra-Ca O.R. (bone-diet) which appear consistent with the literature value for Sapporo and Kyoto by Ohno using a Rn emanation method. Specific effective energies for alpha radiation from 226 Ra and daughters were calculated using the ICRP dosimetric model for bone incorporating masses of source and target organs of Reference Japanese Man. Reference Japanese data including the adult, adolescent, child and infant of both sexes was extensively and intensively studied by Tanaka as part of the activities of the ICRP Task Group on Reference Man Revision. Normal data for the physical measurements, mass and dimension of internal organs and body surfaces and some of the body composition were analysed viewing the nutritional data in the Japanese population. Some of the above works are to be continued. (author)

  16. 85Kr management trade-offs: a perspective to total radiation dose commitment

    International Nuclear Information System (INIS)

    Mellinger, P.J.; Hoenes, G.R.; Brackenbush, L.W.; Greenborg, J.

    1980-01-01

    Radiological consequences arising from the trade-offs for 85 Kr waste management from possible nuclear fuel resource recovery activities have been investigated. The reference management technique is to release all the waste gas to the atmosphere where it is diluted and dispersed. A potential alternative is to collect, concentrate, package and submit the gas to long-term storage. This study compares the radiation dose commitment to the public and to the occupationally exposed work force from these alternatives. The results indicate that it makes little difference to the magnitude of the world population dose whether 85 Kr is captured and stored or chronically released to the environment. Further, comparisons of radiation exposures (for the purpose of estimating health effects) at very low dose rates to very large populations with exposures to a small number of occupationally exposed workers who each receive much higher dose rates may be misleading. Finally, cost studies (EPA 1976 and DOE 1979a) show that inordinate amounts of money will be required to lower this already extremely small 80-year cumulative world population dose of 0.05 mrem/person

  17. RESRAD for Radiological Risk Assessment. Comparison with EPA CERCLA Tools - PRG and DCC Calculators

    Energy Technology Data Exchange (ETDEWEB)

    Yu, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Cheng, J. -J. [Argonne National Lab. (ANL), Argonne, IL (United States); Kamboj, S. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-07-01

    The purpose of this report is two-fold. First, the risk assessment methodology for both RESRAD and the EPA’s tools is reviewed. This includes a review of the EPA’s justification for 2 using a dose-to-risk conversion factor to reduce the dose-based protective ARAR from 15 to 12 mrem/yr. Second, the models and parameters used in RESRAD and the EPA PRG and DCC Calculators are compared in detail, and the results are summarized and discussed. Although there are suites of software tools in the RESRAD family of codes and the EPA Calculators, the scope of this report is limited to the RESRAD (onsite) code for soil contamination and the EPA’s PRG and DCC Calculators also for soil contamination.

  18. Blue Book: EPA Radiogenic Cancer Risk Models and Projections for the U.S. Population

    Science.gov (United States)

    This document presents EPA estimates of cancer incidence and mortality risk coefficients pertaining to low dose exposures to ionizing radiation for the U.S. population, as well as their scientific basis.

  19. Validation of the AIRDOS-EPA computer code by simulating intermediate range transport of /sup 85/Kr from the Savannah River Plant

    Energy Technology Data Exchange (ETDEWEB)

    Fields, D E; Miller, C W; Cotter, S J

    1984-01-01

    The AIRDOS-EPA computer code is used to estimate the annual doses to the general public resulting from releases of radionuclides to the atmosphere. It has been chosen by the US EPA as part of the process for setting radionuclide emission standards for US NRC licensed facilities and US DOE facilities. This code uses a modified Gaussian plume equation to estimate air concentrations resulting from the release of a maximum of 36 radionuclides. Radionuclide concentrations in food products are estimated from the output of the atmospheric transport model using the terrestrial transport model described in US Nuclear Regulatory Commission Regulatory Guide 1.1109. Doses to man at each distance and direction specified are estimated for up to eleven organs and five exposure modes. One year of weekly average /sup 85/Kr concentration observed at 13 stations located 30-150 km distant from a point source at the Savannah River Plant, Aiken, South Carolina, have been used in a validation study of the atmospheric transport portion of AIRDOS-EPA. The predicted annual average concentration at each station exceeded the observed value in every case. The overprediction factor ranged from 1.4 to 3.4 with an average value of 2.4. Pearson's correlation between pairs of logarithms of observed and predicted values was r=0.93. As the averaging time of the prediction decreases, however, the uncertainty in the prediction increases. For example, monthly values show more scatter than do annual or seasonal values. When observed and predicted values or the seasonal average concentrations for each station were compared, we found increasing agreement as we compared spring, summer, fall, and winter values. 26 references, 8 figures, 2 tables.

  20. A reference dosimetric system for dose interval of radiotherapy based on alanine/RPE; Um sistema dosimetrico de referencia para o intervalo de doses da radioterapia baseado na alanina/RPE

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues Junior, Orlando; Galante, Ocimar L.; Campos, Leticia L. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: rodrijr@net.ipen.br

    2001-07-01

    This work describes the development of a reference dosimetric system based on alanine/EPR for radiotherapy dose levels. Currently the IPEN is concluding a similar system for the dose range used for irradiation of products, 10-10{sup 5} Gy. The objective of this work is to present the efforts towards to improve the measure accuracy for doses in the range between 1-10 Gy. This system could be used as reference by radiotherapy services, as much in the quality control of the equipment, as for routine accompaniment of more complex handling where the total doses can reach some grays. The system uses alanine as detector and electronic paramagnetic resonance - EPR as measure technique. To reach accuracy better than 5% mathematical studies on the best optimization of the EPR spectrometer parameters and methods for the handling of the EPR sign are discussed. (author)

  1. "Slicer" for EPA

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    During the design of the Electron-Positron-Accumulator (EPA), there was an apprehension about the stability-limit of positron bunch-intensity in the SPS. In case that EPA would be able to produce bunches with intensities exceeding what the SPS could digest, an electrostatic septum was to slice up the EPA beam over 2 or 4 turns, thus lowering the bunch intensity while maintaining fast filling of LEP. The "slicer" septum was built and installed, but thanks to the good appetite of the SPS its use never became necessary. The slicer was removed from EPA to lower the machine impedance.

  2. Combined methodology for estimating dose rates and health effects from exposure to radioactive pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Dunning, D.E. Jr.; Leggett, R.W.; Yalcintas, M.G.

    1980-12-01

    The work described in the report is basically a synthesis of two previously existing computer codes: INREM II, developed at the Oak Ridge National Laboratory (ORNL); and CAIRD, developed by the Environmental Protection Agency (EPA). The INREM II code uses contemporary dosimetric methods to estimate doses to specified reference organs due to inhalation or ingestion of a radionuclide. The CAIRD code employs actuarial life tables to account for competing risks in estimating numbers of health effects resulting from exposure of a cohort to some incremental risk. The combined computer code, referred to as RADRISK, estimates numbers of health effects in a hypothetical cohort of 100,000 persons due to continuous lifetime inhalation or ingestion of a radionuclide. Also briefly discussed in this report is a method of estimating numbers of health effects in a hypothetical cohort due to continuous lifetime exposure to external radiation. This method employs the CAIRD methodology together with dose conversion factors generated by the computer code DOSFACTER, developed at ORNL; these dose conversion factors are used to estimate dose rates to persons due to radionuclides in the air or on the ground surface. The combination of the life table and dosimetric guidelines for the release of radioactive pollutants to the atmosphere, as required by the Clean Air Act Amendments of 1977.

  3. The Pattern of Fatty Acids Displaced by EPA and DHA Following 12 Months Supplementation Varies between Blood Cell and Plasma Fractions

    Directory of Open Access Journals (Sweden)

    Celia G. Walker

    2015-08-01

    Full Text Available Eicosapentaenoic acid (EPA and docosahexaenoic acid (DHA are increased in plasma lipids and blood cell membranes in response to supplementation. Whilst arachidonic acid (AA is correspondingly decreased, the effect on other fatty acids (FA is less well described and there may be site-specific differences. In response to 12 months EPA + DHA supplementation in doses equivalent to 0–4 portions of oily fish/week (1 portion: 3.27 g EPA+DHA multinomial regression analysis was used to identify important FA changes for plasma phosphatidylcholine (PC, cholesteryl ester (CE and triglyceride (TAG and for blood mononuclear cells (MNC, red blood cells (RBC and platelets (PLAT. Dose-dependent increases in EPA + DHA were matched by decreases in several n-6 polyunsaturated fatty acids (PUFA in PC, CE, RBC and PLAT, but were predominantly compensated for by oleic acid in TAG. Changes were observed for all FA classes in MNC. Consequently the n-6:n-3 PUFA ratio was reduced in a dose-dependent manner in all pools after 12 months (37%–64% of placebo in the four portions group. We conclude that the profile of the FA decreased in exchange for the increase in EPA + DHA following supplementation differs by FA pool with implications for understanding the impact of n-3 PUFA on blood lipid and blood cell biology.

  4. The Pattern of Fatty Acids Displaced by EPA and DHA Following 12 Months Supplementation Varies between Blood Cell and Plasma Fractions.

    Science.gov (United States)

    Walker, Celia G; West, Annette L; Browning, Lucy M; Madden, Jackie; Gambell, Joanna M; Jebb, Susan A; Calder, Philip C

    2015-08-03

    Eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) are increased in plasma lipids and blood cell membranes in response to supplementation. Whilst arachidonic acid (AA) is correspondingly decreased, the effect on other fatty acids (FA) is less well described and there may be site-specific differences. In response to 12 months EPA + DHA supplementation in doses equivalent to 0-4 portions of oily fish/week (1 portion: 3.27 g EPA+DHA) multinomial regression analysis was used to identify important FA changes for plasma phosphatidylcholine (PC), cholesteryl ester (CE) and triglyceride (TAG) and for blood mononuclear cells (MNC), red blood cells (RBC) and platelets (PLAT). Dose-dependent increases in EPA + DHA were matched by decreases in several n-6 polyunsaturated fatty acids (PUFA) in PC, CE, RBC and PLAT, but were predominantly compensated for by oleic acid in TAG. Changes were observed for all FA classes in MNC. Consequently the n-6:n-3 PUFA ratio was reduced in a dose-dependent manner in all pools after 12 months (37%-64% of placebo in the four portions group). We conclude that the profile of the FA decreased in exchange for the increase in EPA + DHA following supplementation differs by FA pool with implications for understanding the impact of n-3 PUFA on blood lipid and blood cell biology.

  5. Report: Improvements Needed by EPA to Reduce Risk in Employee Hiring Process

    Science.gov (United States)

    Report #15-P-0253, August 3, 2015. Without verification of prior employment or references, the potential exists that the EPA will not hire the best possible staff, or will hire an employee based on false statements.

  6. Impact on Dose Coefficients Calculated with ICRP Adult Mesh-type Reference Computational Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Yeon Soo; Nguyen, Thang Tat; Choi, Chan Soo; Lee, Han Jin; Han, Hae Gin; Han, Min Cheol; Shin, Bang Ho; Kim, Chan Hyeong [Dept. of Nuclear Engineering, Hanyang University, Seoul (Korea, Republic of)

    2017-04-15

    In 2016, the International Commission on Radiological Protection (ICRP) formulated a new Task Group (TG) (i.e., TG 103) within Committee 2. The ultimate aim of the TG 103 is to develop the mesh-type reference computational phantoms (MRCPs) that can address dosimetric limitations of the currently used voxel-type reference computational phantoms (VRCPs) due to their limited voxel resolutions. The objective of the present study is to investigate dosimetric impact of the adult MRCPs by comparing dose coefficients (DCs) calculated with the MRCPs for some external and internal exposure cases and the reference DCs in ICRP Publications 116 and 133 that were produced with the adult VRCPs. In the present study, the DCs calculated with the adult MRCPs for some exposure cases were compared with the values in ICRP Publications 116 and 133. This comparison shows that in general the MRCPs provide very similar DCs for uncharged particles, but for charged particles provide significantly different DCs due to the improvement of the MRCPs.

  7. Background and anthropogenic radionuclide derived dose rates to freshwater ecosystem - Nuclear power plant cooling pond - Reference organisms

    International Nuclear Information System (INIS)

    Nedveckaite, T.; Filistovic, V.; Marciulioniene, D.; Prokoptchuk, N.; Plukiene, R.; Gudelis, A.; Remeikis, V.; Yankovich, T.; Beresford, N.-A.

    2011-01-01

    The radiological assessment of non-human biota to demonstrate protection is now accepted by a number of international and national bodies. Therefore, it is necessary to develop a scientific basis to assess and evaluate exposure of biota to ionizing radiation. Radionuclides from the Ignalina Nuclear Power Plant (Lithuania) were discharged into Lake Druksiai cooling pond. Additional radionuclide migration and recharge to this lake from a hypothetical near-surface, low-level radioactive waste disposal, to be situated 1.5 km from the lake, had been simulated using RESRAD-OFFSITE code. This paper uses ERICA Integrated Approach with associated tools and databases to compare the radiological dose to freshwater reference organisms. Based on these data, it can be concluded that background dose rates to non-human biota in Lake Druksiai far exceed those attributable to anthropogenic radionuclides. With respect the fishery and corresponding annual committed effective human dose as a result of this fish consumption Lake Druksiai continues to be a high-productivity water body with intensive angling and possible commercial fishing. - Highlights: → Dose rates to the reference organisms are lower than expected from the background radioactivity. → Pelagic fish part of adult human annual committed effective dose would be as small as a few μSv y -1 . → With respect the fishery Lake Druksiai continues to be a high-productivity water body.

  8. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : le mardi 29 novembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  9. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2013-01-01

    Carte de membre de l'Association du personnel du CERN Comme cela a été précisé dans le bulletin d'automne n° 43, les membres GAC-EPA qui souhaitent recevoir une carte de membre AP en 2013 devront en faire la demande, avant le 31 janvier, par email à secretariat@gac-epa.org, ou par lettre au secrétaire du GAC-EPA, p/a Association du personnel CERN, CH-1211 GENEVE 23. Il n'y a pas de tacite reconduction de ces cartes et par conséquent une demande doit être faite chaque année par l'intéressé(e).

  10. Medical reference dosimetry using EPR measurements of alanine: Development of an improved method for clinical dose levels

    International Nuclear Information System (INIS)

    Helt-Hansen, Jakob; Andersen, Claus Erik; Rosendal, Flemming; Kofoed, Inger Matilde

    2009-01-01

    Electron spin resonance (EPR) is used to determine the absorbed dose of alanine dosimeters exposed to clinical photon beams in a solid-water phantom. Alanine is potentially suitable for medical reference dosimetry, because of its near water equivalence over a wide energy spectrum, low signal fading, non-destructive measurement and small dosimeter size. Material and Methods. A Bruker EMX-micro EPR spectrometer with a rectangular cavity and a measurement time of two minutes per dosimeter was used for reading of irradiated alanine dosimeters. Under these conditions a new algorithm based on scaling of known spectra was developed to extract the alanine signal. Results. The dose accuracy, including calibration uncertainty, is less than 2% (k=1) above 4 Gy (n=4). The measurement uncertainty is fairly constant in absolute terms (∼30 mGy) and the relative uncertainty therefore rises for dose measurements below 4 Gy. Typical reproducibility is <1% (k=1) above 10 Gy and <2% between 4 and 10 Gy. Below 4 Gy the uncertainty is higher. A depth dose curve measurement was performed in a solid-water phantom irradiated to a dose of 20 Gy at the maximum dose point (dmax) in 6 and 18 MV photon beams. The typical difference between the dose measured with alanine in solid water and the dose measured with an ion chamber in a water tank was about 1%. A difference of 2% between 6 and 18 MV was found, possibly due to non-water equivalence of the applied phantom. Discussion. Compared to previously published methods the proposed algorithm can be applied without normalisation of phase shifts caused by changes in the g-value of the cavity. The study shows that alanine dosimetry is a suitable candidate for medical reference dosimetry especially for quality control applications

  11. Determination of dose to patient in different teams of TC and assessment with international reference levels

    International Nuclear Information System (INIS)

    Ruiz Morales, C.; Fernandez lara, A. A.; Buades Forner, M. J.; Tobarra Gonzalez, B. M.

    2013-01-01

    The increase in CT studies and the differences observed between the different equipment used in our hospital prompted us to determine the doses to patients in different studies and check the results obtained with the reference values published internationally. (Author)

  12. 85Kr management trade-offs: a perspective to total radiation dose commitment

    Energy Technology Data Exchange (ETDEWEB)

    Mellinger, P.J.; Hoenes, G.R.; Brackenbush, L.W.; Greenborg, J.

    1980-01-01

    Radiological consequences arising from the trade-offs for /sup 85/Kr waste management from possible nuclear fuel resource recovery activities have been investigated. The reference management technique is to release all the waste gas to the atmosphere where it is diluted and dispersed. A potential alternative is to collect, concentrate, package and submit the gas to long-term storage. This study compares the radiation dose commitment to the public and to the occupationally exposed work force from these alternatives. The results indicate that it makes little difference to the magnitude of the world population dose whether /sup 85/Kr is captured and stored or chronically released to the environment. Further, comparisons of radiation exposures (for the purpose of estimating health effects) at very low dose rates to very large populations with exposures to a small number of occupationally exposed workers who each receive much higher dose rates may be misleading. Finally, cost studies (EPA 1976 and DOE 1979a) show that inordinate amounts of money will be required to lower this already extremely small 80-year cumulative world population dose of 0.05 mrem/person (<0.001% of natural background radiation for the same time period).

  13. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2015-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 1er décembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  14. Regional Diagnostic Reference Levels and Collective Effective Doses from Computed Tomography (CT) Scanners in India

    International Nuclear Information System (INIS)

    Livingstone, R.S.; Dinakaran, P.M.

    2011-01-01

    Diagnostic examinations performed using computed tomography (CT) are on the increase, and the use of this modality needs to be monitored periodically. The aim of this study was to formulate regional diagnostic reference levels (DRLs) and assess collective effective doses from CT scanners in Tamil Nadu, India. In-site CT dose measurements were performed for 127 CT scanners in Tamil Nadu as a part of the Atomic Energy Regulatory Board (AERB) funded project for a period of two years. Regional DRLs were formulated at third quartile level for three CT protocols such as thorax, abdomen and pelvis and were found to be 557 mGy.cm, 521 mGy.cm and 294 mGy.cm, respectively. The collective effective dose in Tamil Nadu was found to be 14.93 man Sv per day. (author)

  15. EPA eXcats

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA eXcats is an enterprise-level data tracking application that provides management complaint tracking information for the EPA's Office of Civil Rights (OCR)...

  16. EPA Web Taxonomy

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPA's Web Taxonomy is a faceted hierarchical vocabulary used to tag web pages with terms from a controlled vocabulary. Tagging enables search and discovery of EPA's...

  17. Updating Dosimetry for Emergency Response Dose Projections.

    Science.gov (United States)

    DeCair, Sara

    2016-02-01

    In 2013, the U.S. Environmental Protection Agency (EPA) proposed an update to the 1992 Protective Action Guides (PAG) Manual. The PAG Manual provides guidance to state and local officials planning for radiological emergencies. EPA requested public comment on the proposed revisions, while making them available for interim use by officials faced with an emergency situation. Developed with interagency partners, EPA's proposal incorporates newer dosimetric methods, identifies tools and guidelines developed since the current document was issued, and extends the scope of the PAGs to all significant radiological incidents, including radiological dispersal devices or improvised nuclear devices. In order to best serve the emergency management community, scientific policy direction had to be set on how to use International Commission on Radiological Protection Publication 60 age groups in dose assessment when implementing emergency guidelines. Certain guidelines that lend themselves to different PAGs for different subpopulations are the PAGs for potassium iodide (KI), food, and water. These guidelines provide age-specific recommendations because of the radiosensitivity of the thyroid and young children with respect to ingestion and inhalation doses in particular. Taking protective actions like using KI, avoiding certain foods or using alternative sources of drinking water can be relatively simple to implement by the parents of young children. Clear public messages can convey which age groups should take which action, unlike how an evacuation or relocation order should apply to entire households or neighborhoods. New in the PAG Manual is planning guidance for the late phase of an incident, after the situation is stabilized and efforts turn toward recovery. Because the late phase can take years to complete, decision makers are faced with managing public exposures in areas not fully remediated. The proposal includes quick-reference operational guidelines to inform re-entry to

  18. Biota Modeling in EPA's Preliminary Remediation Goal and Dose Compliance Concentration Calculators for Use in EPA Superfund Risk Assessment: Explanation of Intake Rate Derivation, Transfer Factor Compilation, and Mass Loading Factor Sources

    International Nuclear Information System (INIS)

    Manning, Karessa L.; Dolislager, Fredrick G.; Bellamy, Michael B.

    2016-01-01

    The Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) calculators are screening level tools that set forth Environmental Protection Agency's (EPA) recommended approaches, based upon currently available information with respect to risk assessment, for response actions at Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) sites, commonly known as Superfund. The screening levels derived by the PRG and DCC calculators are used to identify isotopes contributing the highest risk and dose as well as establish preliminary remediation goals. Each calculator has a residential gardening scenario and subsistence farmer exposure scenarios that require modeling of the transfer of contaminants from soil and water into various types of biota (crops and animal products). New publications of human intake rates of biota; farm animal intakes of water, soil, and fodder; and soil to plant interactions require updates be implemented into the PRG and DCC exposure scenarios. Recent improvements have been made in the biota modeling for these calculators, including newly derived biota intake rates, more comprehensive soil mass loading factors (MLFs), and more comprehensive soil to tissue transfer factors (TFs) for animals and soil to plant transfer factors (BV's). New biota have been added in both the produce and animal products categories that greatly improve the accuracy and utility of the PRG and DCC calculators and encompass greater geographic diversity on a national and international scale.

  19. The Pattern of Fatty Acids Displaced by EPA and DHA Following 12 Months Supplementation Varies between Blood Cell and Plasma Fractions

    OpenAIRE

    Walker, Celia G.; West, Annette L.; Browning, Lucy M.; Madden, Jackie; Gambell, Joanna M.; Jebb, Susan A.; Calder, Philip C.

    2015-01-01

    Eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) are increased in plasma lipids and blood cell membranes in response to supplementation. Whilst arachidonic acid (AA) is correspondingly decreased, the effect on other fatty acids (FA) is less well described and there may be site-specific differences. In response to 12 months EPA + DHA supplementation in doses equivalent to 0–4 portions of oily fish/week (1 portion: 3.27 g EPA+DHA) multinomial regression analysis was used to identify...

  20. Plan for implementing EPA standards for UMTRA sites

    International Nuclear Information System (INIS)

    1984-01-01

    The Uranium Mill Tailings Radiation Control Act of 1978 (UMTRCA), authorizes the Department of Energy (DOE) to undertake remedial actions at 24 DOE designated processing sites. The term ''processing site,'' by statutory definition, means the inactive uranium mill or processing site and any other real property or improvement which is in the vicinity of the mill or processing site and is determined to be contaminated with residual radioactive materials derived from the mill or processing site. For purposes of this document, the inactive mill or processing site is referred to as the ''processing site'' and the other real property or improvement in the vicinity of such site is referred to as a 'vicinity property.'' The purpose of the remedial actions is to stabilize and control the uranium mill tailings and other residual radioactive materials in a safe and environmentally sound manner. Remedial actions undertaken by DOE are to be accomplished: With the full participation of the affected states and Indian tribes, in accordance with standards issued by the Environmental Protection Agency (EPA), and with the concurrence of the Nuclear Regulatory Commission (NRC). This plan is designed to be a generic presentation on methodology that will be followed in implementing the EPA standards. 5 refs., 1 tab

  1. GAC-EPA

    CERN Document Server

    GAC-EPA

    2013-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 1er octobre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 5 novembre et 3 décembre 2013. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  2. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : le mardi 1er novembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel. La permanence suivante aura lieu le mardi 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  3. GAC-EPA

    CERN Document Server

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 4 octobre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 1er et 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  4. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2015-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 3 novembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel La permanence suivante aura lieu le mardi 1er décembre 2015. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  5. Reference beta radiations for calibrating dosemeters and dose ratemeters and for determining their response as a function of beta radiation energy. 1. ed.

    International Nuclear Information System (INIS)

    1984-01-01

    This International Standard specifies the requirements for reference beta radiations produced by radionuclide sources to be used for the calibration of protection level dosemeters and dose ratemeters, and for the determination of their response as a function of beta energy. It gives the characteristics of radionuclides which have been used to produce reference beta radiations, gives examples of suitable source constructions and describes methods for the measurement of the residual maximum beta energy and the absorbed dose rate at a depth of 7 mg·cm -2 in a semi-infinite tissue-equivalent medium. The energy range involved lies between 66 keV and 3.6 MeV and the absorbed dose rates are in the range from about 10 μGy·h -1 (1 mrad·h -1 ) to at least 10 Gy·h -1 (10 3 rad·h -1 ). This International Standard proposes two series of beta reference radiations from which the radiation necessary for determining the characteristics (calibration and energy response) of an instrument shall be selected. Series 1 reference radiations are produced by radionuclide sources used with beam flattening filters designed to give uniform dose rates over a large area at a specific distance. The proposed sources of 90 Sr+ 90 Y, 204 TI and 147 Pm produce maximum dose rates of approximately 5mGy·h -1 (0.5 rad·h -1 ). Series 2 reference radiations are produced without the use of beam flattening filters which allows a range of source-to-calibration plane distances to be used. Close to the sources only relatively small areas of uniform dose rate are produced but this Series has the advantage of extending the energy and dose rate ranges beyond those of Series 1. The radionuclides used are those of Series 1 with the addition of the radionuclides 14 C and 106 Ru+ 106 Rh; these sources produce dose rates of up to 10 Gy·h -1 (10 3 rad·h -1 )

  6. EPA Linked Open Data (Collection)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is a collection item referencing the following EPA Linked Data resources: - EPA Facility Registry Service (FRS) - EPA Substance Registry Service (SRS) -...

  7. EPA Library Network Communication Strategies

    Science.gov (United States)

    To establish Agency-wide procedures for the EPA National Library Network libraries to communicate, using a range of established mechanisms, with other EPA libraries, EPA staff, organizations and the public.

  8. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 5 avril de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 3 mai, 7 juin, 6 septembre, 4 octobre, 1er et 29 novembre décembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  9. GAC-EPA

    CERN Document Server

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 3 mai de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 7 juin, 6 septembre, 4 octobre, 1er et 29 novembre décembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  10. GAC-EPA

    CERN Document Server

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 5 avril de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 3 mai, 7 juin, 6 septembre, 4 octobre, 1er et 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  11. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 1er mars de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 5 avril, 3 mai, 7 juin, 6 septembre, 4 octobre, 1er et 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  12. 77 FR 46964 - Oklahoma: Incorporation by Reference of Approved State Hazardous Waste Management Program

    Science.gov (United States)

    2012-08-07

    ...: Incorporation by Reference of Approved State Hazardous Waste Management Program AGENCY: Environmental Protection... Agency (EPA) to authorize States to operate their hazardous waste management programs in lieu of the Federal program. The EPA uses the regulations entitled ``Approved State Hazardous Waste Management...

  13. 77 FR 29231 - Oklahoma: Incorporation by Reference of Approved State Hazardous Waste Management Program

    Science.gov (United States)

    2012-05-17

    ...: Incorporation by Reference of Approved State Hazardous Waste Management Program AGENCY: Environmental Protection... Agency (EPA) to authorize States to operate their hazardous waste management programs in lieu of the Federal program. The EPA uses the regulations entitled ``Approved State Hazardous Waste Management...

  14. 75 FR 45489 - New York: Incorporation by Reference of State Hazardous Waste Management Program

    Science.gov (United States)

    2010-08-03

    ...: Incorporation by Reference of State Hazardous Waste Management Program AGENCY: Environmental Protection Agency... (EPA) to authorize States to operate their hazardous waste management programs in lieu of the Federal program. EPA uses the regulations entitled ``Approved State Hazardous Waste Management Programs'' to...

  15. 75 FR 17332 - Idaho: Incorporation by Reference of Approved State Hazardous Waste Management Program

    Science.gov (United States)

    2010-04-06

    ...: Incorporation by Reference of Approved State Hazardous Waste Management Program AGENCY: Environmental Protection... ``Approved State Hazardous Waste Management Programs,'' Idaho's authorized hazardous waste program. The EPA... regulations that are authorized and that the EPA will enforce under the Solid Waste Disposal Act, commonly...

  16. ANALYSIS OF RESPIRATORY DEPOSITION OF INHALED PARTICLES FOR DIFFERENT DOSE METRICS: COMPARISON OF NUMBER, SURFACE AREA AND MASS DOSE OF TYPICAL AMBIENT BI-MODAL AEROSOLS

    Science.gov (United States)

    ANALYSIS OF RESPIRATORY DEPOSITION OF INHALED PARTICLES FOR DIFFERENT DOSE METRICS: COMPARISON OF NUMBER, SURFACE AREA AND MASS DOSE OF TYPICAL AMBIENT BI-MODAL AEROSOLS.Chong S. Kim, SC. Hu*, PA Jaques*, US EPA, National Health and Environmental Effects Research Laboratory, ...

  17. EPA's SHEDS-multimedia model: children's cumulative pyrethroid exposure estimates and evaluation against NHANES biomarker data

    Science.gov (United States)

    The U.S. EPA's SHEDS-Multimedia model was applied to enhance the understanding of children's exposures and doses to multiple pyrethroid pesticides, including major contributing chemicals and pathways. This paper presents combined dietary and residential exposure estimates and cum...

  18. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2015-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 3 mars de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 7 avril, 5 mai, 2 juin, 1er septembre, 6 octobre, 3 novembre et 1er décembre 2013. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  19. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 2 février de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 1er mars, 5 avril, 3 mai, 7 juin, 6 septembre, 4 octobre, 1er et 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  20. A Study of the Differential Effects of Eicosapentaenoic Acid (EPA) and Docosahexaenoic Acid (DHA) on Gene Expression Profiles of Stimulated Thp-1 Macrophages.

    Science.gov (United States)

    Allam-Ndoul, Bénédicte; Guénard, Frédéric; Barbier, Olivier; Vohl, Marie-Claude

    2017-04-25

    Background: An appropriate intake of omega-3 ( n -3) fatty acids (FAs) such as eicosapentaenoic and docosahexaenoic acid (EPA/DHA) from marine sources is known to have anti-inflammatory effects. However, molecular mechanisms underlying their beneficial effects on health are not fully understood. The aim of the present study was to characterize gene expression profiles of THP-1 macrophages, incubated in either EPA or DHA and stimulated with lipopolysaccharide (LPS), a pro-inflammatory agent. Methods: THP-1 macrophages were incubated into 10, 50 and 75 µM of EPA or DHA for 24 h, and 100 nM of LPS was added to the culture media for 18 h. Total mRNA was extracted and gene expression examined by microarray analysis using Illumina Human HT-12 expression beadchips (Illumina). Results: Pathway analysis revealed that EPA and DHA regulate genes involved in cell cycle regulation, apoptosis, immune response and inflammation, oxidative stress and cancer pathways in a differential and dose-dependent manner. Conclusions: EPA and DHA appear to exert differential effects on gene expression in THP-1 macrophages. Specific effects of n -3 FAs on gene expression levels are also dose-dependent.

  1. Patient radiation doses and reference levels in pediatric interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Habib Geryes, Bouchra; Lachaux, Julie; Boddaert, Nathalie; Brunelle, Francis [Hopital Universitaire Necker Enfants Malades, Department of Paediatric Radiology, Paris (France); Bak, Adeline; Ozanne, Augustin; Saliou, Guillaume [Hopital Bicetre, Hopitaux Universitaires Paris-Sud, Department of Neuroradiology, Le Kremlin Bicetre (France); Naggara, Olivier [Hopital Universitaire Necker Enfants Malades, Department of Paediatric Radiology, Paris (France); Centre Hospitalier Sainte-Anne, Universite Paris Descartes Sorbonne Paris Cite, Centre de Psychiatrie et Neurosciences, INSERM S894, DHU Neurovasculaire, Paris (France); Centre Hospitalier Sainte-Anne, Department of Neuroradiology, Universite Paris Descartes, Sorbonne Paris Cite, INSERM UMR894, Paris (France)

    2017-09-15

    To describe, in a multicentric paediatric population, reference levels (RLs) for three interventional radiological procedures. From January 2012 to March 2015, children scheduled for an interventional radiological procedure in two French tertiary centres were retrospectively included and divided into four groups according to age: children younger than 2 years (A1), aged 2-7 years (A5), 8-12 years (A10) and 13-18 years (A15). Three procedures were identified: cerebral digital subtraction angiography (DSA), brain arteriovenous malformation (bAVM) embolization, and head and neck superficial vascular malformation (SVM) percutaneous sclerotherapy. Demographic and dosimetric data, including dose area product (DAP), were collected. 550 procedures were included. For DSA (162 procedures), the proposed RL values in DAP were 4, 18, 12 and 32 Gy.cm{sup 2} in groups A1, A5, A10 and A15, respectively. For bAVM embolization (258 procedures), values were 33, 70, 105 and 88 Gy.cm{sup 2} in groups A1, A5, A10 and A15, respectively. For SVM sclerotherapy (130 procedures), values were 350, 790, 490 and 248 mGy.cm{sup 2} in groups A1, A5, A10 and A15, respectively. Consecutive data were available to permit a proposal of reference levels for three major paediatric interventional radiology procedures. (orig.)

  2. EPA for Businesses and Non-Profits

    Science.gov (United States)

    Information and links to EPA web pages that are meant to help businesses and non-profits adhere to EPA regulations and otherwise protect the environment, take advantage of opportunities to collaborate with the EPA, and find training EPA training programs.

  3. Bioequivalence of fixed-dose combination Myrin®-P Forte and reference drugs in loose combination.

    Science.gov (United States)

    Wang, H F; Wang, R; O'Gorman, M; Crownover, P; Naqvi, A; Jafri, I

    2013-12-01

    Myrin®-P Forte is a fixed-dose combination (FDC) tablet containing rifampicin (RMP, 150 mg), isoniazid (INH, 75 mg), ethambutol (EMB) hydrochloride (275 mg) and pyrazinamide (PZA, 400 mg) developed for the treatment of tuberculosis (TB). This study was conducted at a single centre--the Pfizer Clinical Research Unit in Singapore. To demonstrate the bioequivalence of each drug component of the Myrin-P Forte FDC and the individual product in loose combination. In a randomized, open-label, single-dose, two-way, crossover study, subjects received single doses of Myrin-P Forte or four individual products under fasting conditions in a crossover fashion with at least 7 days washout between doses. The primary measures for comparison were peak plasma concentration (C(max)) and the area under plasma concentration-time curve (AUC). Of 36 subjects enrolled, 35 completed the study. The adjusted geometric mean ratios and 90% confidence intervals for C(max) and AUC values were completely contained within bioequivalence limits (80%, 125%) for all four drugs in both formulations. Both treatments were generally well tolerated in the study. The Myrin-P Forte FDC tablet formulation is bioequivalent to the four single-drug references for RMP, INH, EMB hydrochloride and PZA at equivalent doses.

  4. EPA Administrative Enforcement Dockets

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA Administrative Enforcement Dockets database contains the electronic dockets for administrative penalty cases filed by EPA Regions and Headquarters. Visitors...

  5. Memorandum of Understanding Between U.S. EPA Superfund and U.S. NRC

    International Nuclear Information System (INIS)

    Walker, Stuart

    2008-01-01

    that NRC should consider that address the site-specific matter that triggered consultation. Over the course of consultations on the eight sites, there have been some reoccurring themes to EPA's views. Primarily, these are EPA: 1. Recommending that NRC consider selecting institutional controls to ensure that NRC's assumptions about future human exposure at the site are not exceeded. 2. Recommending that NRC consider using more site-specific information when conducting dose assessment modeling. 3. Recommending that NRC consider a flexible approach to groundwater protection that still ensures the public is not exposed to contamination levels over drinking water limits. 4. Recommending that NRC consider an approach similar to how EPA implements supplemental standards under 40 CFR 192 as an ARAR when the UMTRCA soil standard of 5 pCi/g is not being met

  6. Patient dose measurements in fluoroscopic examinations, aiming to the establishment of reference levels in Brazil

    International Nuclear Information System (INIS)

    Canevaro, L.; Drexler, G.

    2001-01-01

    This work was performed to investigate the actual exposure levels of the patients submitted to fluoroscopic procedures in diagnostic radiology. The data will be useful for a baseline in the establishment of local reference levels for fluoroscopic procedures, as recommended by the European Commission and IAEA. At present time there are no internationally accepted definitions for references levels for fluoroscopic complex procedures. Dose-area product (DAP) meters were employed in a pilot survey expressing the radiation exposures in terms of this quantity. This class of instrumentation has not yet been employed in Brazil. Parameters recorded were radiographic technique, fluoroscopy time, number of images, fluoroscopic and radiographic field sizes and DAPs. For fluoroscopy practice, a reference parameters set is recommended, instead of one diagnostic reference level. High patient exposures were found, calling for joined actions of health authorities, physicians, medical physicists, technicians and manufacturers. Monitoring of patient exposure, optimizing the radiation protection and establishing quantitative assessments of the exposition to the population in Brazil in this kind of procedure is important. (author)

  7. Biota Modeling in EPA's Preliminary Remediation Goal and Dose Compliance Concentration Calculators for Use in EPA Superfund Risk Assessment: Explanation of Intake Rate Derivation, Transfer Factor Compilation, and Mass Loading Factor Sources

    Energy Technology Data Exchange (ETDEWEB)

    Manning, Karessa L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Dolislager, Fredrick G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bellamy, Michael B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    The Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) calculators are screening level tools that set forth Environmental Protection Agency's (EPA) recommended approaches, based upon currently available information with respect to risk assessment, for response actions at Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) sites, commonly known as Superfund. The screening levels derived by the PRG and DCC calculators are used to identify isotopes contributing the highest risk and dose as well as establish preliminary remediation goals. Each calculator has a residential gardening scenario and subsistence farmer exposure scenarios that require modeling of the transfer of contaminants from soil and water into various types of biota (crops and animal products). New publications of human intake rates of biota; farm animal intakes of water, soil, and fodder; and soil to plant interactions require updates be implemented into the PRG and DCC exposure scenarios. Recent improvements have been made in the biota modeling for these calculators, including newly derived biota intake rates, more comprehensive soil mass loading factors (MLFs), and more comprehensive soil to tissue transfer factors (TFs) for animals and soil to plant transfer factors (BV's). New biota have been added in both the produce and animal products categories that greatly improve the accuracy and utility of the PRG and DCC calculators and encompass greater geographic diversity on a national and international scale.

  8. US EPA Region 4 Brownfields

    Science.gov (United States)

    To improve public health and the environment, the United States Environmental Protection Agency (USEPA) collects information about facilities, sites, or places subject to environmental regulation or of environmental interest. Through the Geospatial Data Download Service, the public is now able to download the EPA Geodata shapefile containing facility and site information from EPA's national program systems. The file is Internet accessible from the Envirofacts Web site (https://www3.epa.gov/enviro/). The data may be used with geospatial mapping applications. (Note: The shapefile omits facilities without latitude/longitude coordinates.) The EPA Geospatial Data contains the name, location (latitude/longitude), and EPA program information about specific facilities and sites. In addition, the file contains a Uniform Resource Locator (URL), which allows mapping applications to present an option to users to access additional EPA data resources on a specific facility or site. This dataset shows Brownfields listed in the 2012 Facility Registry System.

  9. The calculation of dose from photon exposures using reference human phantoms and Monte Carlo methods. Pt. 5

    International Nuclear Information System (INIS)

    Petoussi, N.; Zankl, M.; Williams, G.; Veit, R.; Drexler, G.

    1987-01-01

    There has been some evidence that cervical cancer patients who were treated by radiotherapy, had an increased incidence of second primary cancers noticeable 15 years or more after the radiotherapy. The data suggested that high dose pelvic irradiation was associated with increase in cancers of the bladder, kidneys, rectum, ovaries, corpus uteri, and non-Hodgkin's lymphoma but not leukemia (Kleinerman et al., 1982, Morton 1973). The aim of the present work is to estimate the absorbed dose, due to radiotherapy treatment for cervival cancer, to various organs and tissues in the body. Monte Carlo calculations were performed to calculate the organ absorbed doses resulting from intracavitary sources such as ovoids and applicators filled or loaded with radium, Co-60 and Cs-137. For that purpose a routine which simulates an internal source was constructed and added to the existing Monte Carlo code (GSF-Bericht S-885, Kramer et al.). Calculations were also made for external beam therapy. Various anterior, posterior and lateral fields were applied, resulting from megavoltage, Co-60 and Cs-137 therapy machines. The calculated organ doses are tabulated in three different ways: as organ dose per air Kerma in the reference field, according to the recommendations of the International Commission on Radiation Units and Measurements (ICRU Report No 38, 1985); as organ dose per surface dose and as organ dose per tissue dose at Point B. (orig.)

  10. Diagnostic reference levels for common computed tomography (CT) examinations: results from the first Nigerian nationwide dose survey.

    Science.gov (United States)

    Ekpo, Ernest U; Adejoh, Thomas; Akwo, Judith D; Emeka, Owujekwe C; Modu, Ali A; Abba, Mohammed; Adesina, Kudirat A; Omiyi, David O; Chiegwu, Uche H

    2018-01-29

    To explore doses from common adult computed tomography (CT) examinations and propose national diagnostic reference levels (nDRLs) for Nigeria. This retrospective study was approved by the Nnamdi Azikiwe University and University Teaching Hospital Institutional Review Boards (IRB: NAUTH/CS/66/Vol8/84) and involved dose surveys of adult CT examinations across the six geographical regions of Nigeria and Abuja from January 2016 to August 2017. Dose data of adult head, chest and abdomen/pelvis CT examinations were extracted from patient folders. The median, 75th and 25th percentile CT dose index volume (CTDI vol ) and dose-length-product (DLP) were computed for each of these procedures. Effective doses (E) for these examinations were estimated using the k conversion factor as described in the ICRP publication 103 (E DLP  =  k × DLP ). The proposed 75th percentile CTDI vol for head, chest, and abdomen/pelvis are 61 mGy, 17 mGy, and 20 mGy, respectively. The corresponding DLPs are 1310 mGy.cm, 735 mGy.cm, and 1486 mGy.cm respectively. The effective doses were 2.75 mSv (head), 10.29 mSv (chest), and 22.29 mSv (abdomen/pelvis). Findings demonstrate wide dose variations within and across centres in Nigeria. The results also show CTDI vol comparable to international standards, but considerably higher DLP and effective doses.

  11. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 31 janvier de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 28 février, 28 mars, 25 avril, 30 mai, 29 août, 26 septembre, 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  12. Doses from radiation exposure

    International Nuclear Information System (INIS)

    Menzel, H-G.; Harrison, J.D.

    2012-01-01

    Practical implementation of the International Commission on Radiological Protection’s (ICRP) system of protection requires the availability of appropriate methods and data. The work of Committee 2 is concerned with the development of reference data and methods for the assessment of internal and external radiation exposure of workers and members of the public. This involves the development of reference biokinetic and dosimetric models, reference anatomical models of the human body, and reference anatomical and physiological data. Following ICRP’s 2007 Recommendations, Committee 2 has focused on the provision of new reference dose coefficients for external and internal exposure. As well as specifying changes to the radiation and tissue weighting factors used in the calculation of protection quantities, the 2007 Recommendations introduced the use of reference anatomical phantoms based on medical imaging data, requiring explicit sex averaging of male and female organ-equivalent doses in the calculation of effective dose. In preparation for the calculation of new dose coefficients, Committee 2 and its task groups have provided updated nuclear decay data (ICRP Publication 107) and adult reference computational phantoms (ICRP Publication 110). New dose coefficients for external exposures of workers are complete (ICRP Publication 116), and work is in progress on a series of reports on internal dose coefficients to workers from inhaled and ingested radionuclides. Reference phantoms for children will also be provided and used in the calculation of dose coefficients for public exposures. Committee 2 also has task groups on exposures to radiation in space and on the use of effective dose.

  13. Local patient dose diagnostic reference levels in pediatric interventional cardiology in Chile using age bands and patient weight values.

    Science.gov (United States)

    Ubeda, Carlos; Miranda, Patricia; Vano, Eliseo

    2015-02-01

    To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-area product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there may be large differences in child size. These DRLs were obtained at the largest pediatric hospital in Chile, with an active optimization program, and could be used by other hospitals in the Latin America region to compare their current patient dose values and determine whether corrective action is appropriate. © 2015 American Association of Physicists in Medicine.

  14. Use of national metrological references of dose absorbed in water and application of the IAEA TRS nr 398 dosimetry protocol to high energy photon beams. BNM-LNHB-LCIE-SFPM working group

    International Nuclear Information System (INIS)

    Chauvenet, B.; Delaunay, F.; Dolo, J.M.; Le Roy, G.; Bridier, A.; Francois, P.; Sabattier, R.

    2003-01-01

    Metrological references of dose absorbed in water for high energy photon beams used in radiotherapy have been elaborated during the past years by national calibration laboratories, and these new references are the basis of recent dosimetry protocols. However, the passage from metrological references of air kerma to dose absorbed in water, as well as the practical application of new calibration opportunities for dosemeters in high energy X ray beams requires a specific attention to maintain the consistency of dose measurement references over the hospital site. In this respect, this guide aims at the application of these metrological references. It proposes recommendations for the application of metrological references in terms of dose absorbed in water on the hospital site with reference to their determination conditions and to the implementation of the new IAEA dosimetry protocol (TRS nr 398). Thus, this guide proposes an overview of metrological references in French calibration laboratories, presents calibration methods (air kerma in a cobalt 60 gamma photon beam, dose absorbed in water) and a comparison with the IAEA TRS 277 dosimetry protocol. It addresses various practical aspects, and discusses uncertainties

  15. Comparison of the DOE and the EPA risk assessment methodologies and default parameters for the air exposure pathway

    International Nuclear Information System (INIS)

    Tan, Z.; Eckart, R.

    1993-01-01

    The U.S. Department of Energy (DOE) and the U.S. Environmental Protection Agency (EPA) each publish radiological health effects risk assessment methodologies. Those methodologies are in the form of computer program models or extensive documentation. This research paper compares the significant differences between the DOE and EPA methodologies and default parameters for the important air exposure pathway. The purpose of this analysis was to determine the fundamental differences in methodology and parameter values between the DOE and the EPA. This study reviewed the parameter values and default values that are utilized in the air exposure pathway and revealed the significant differences in risk assessment results when default values are used in the analysis of an actual site. The study details the sources and the magnitude of the parameter departures between the DOE and the EPA methodologies and their impact on dose or risk

  16. Comparison of the respiratory tract models of ICRP and US EPA

    International Nuclear Information System (INIS)

    Wu Tao

    2000-01-01

    An index for the integral characterization of risk is necessary for improving risk management, comparing the effects of various practices on the environment and keeping risk as low as reasonably achievable while allowing economic development. Public health risk has been used as an index to compare and combine the risks from the presence of a variety of contaminants. In 1994, International Commission on Radiological Protection published the Publication 66 'Human Respiratory Tract Model for Radiological Protection'. Meanwhile US EPA published 'Methods for Derivation of Inhalation Reference Concentrations and Application of Inhalation Dosimetry'. Basically the concept of Reference Concentration (RfC) is similar to that of DAC used in radiation protection. Both of them are derived from the deposited amount of interested contaminants in the respiratory tract. In an attempt to assess the public health risk by combining the ICRP model and the deposited amount corresponding to values of RfC, the main application, especially the fractional deposition, of the respiratory tract model of US EPA is compared with the new respiratory tract model of ICRP. For normal nose breather, when the AMADs of monodisperse aerosol are 0.5 η m, 1 η m, 2 η m, 3 η m, 5 η m, 7 η m and 10 η m, minute volume is 1.2m 3 /h (20L/mim), the corresponding total fractional depositions calculated by the model of the US EPA are 0.33, 0.50, 0.72, 0.85, 0.95, 0.97 and 0.93. With the same condition, the total fractional deposition calculated by the ICRP model is 0.35, 0.51, 0.70, 0.78, 0.82, 0.81 and 0.77. For polydisperse aerosol with default values of ICRP for occupational and environmental exposures, the fractional depositions calculated by US EPA model are 0.82 and 0.50 while that by ICRP are 0.82 and 0.47. In conclusion, (1) The ICRP model is more accurate than the US EPA model and has a wider application. (2) For monodisperse aerosol, when the AMAD of aerosol is less than 3 η m there is no

  17. Recent trend of radiation doses of medical workers

    Energy Technology Data Exchange (ETDEWEB)

    Anzai, I [Tokyo Univ. (Japan). Faculty of Medicine; Tanaka, M; Nakamura, S; Nawa, H; Nukazawa, A

    1981-10-01

    Radiation doses of medical workers in Japan between 1976 and 1979 were analysed based on the data provided by a film badge servicing company. Average annual radiation doses between April, 1978 and March, 1979 were 129 mrems for 2556 doctors, 108 mrems for 2074 radiographers, and 60 mrems for 1915 nurses. It was also suggested that the log-normal distribution could provide a good fit to the frequency distribution of radiation doses of these medical staffs. Time series data of monthly average doses during the period between April, 1976 and March, 1979 were analysed using a computer code named EPA that had been developed by the Japanese Economic Planning Agency. The EPA code separated the original time series data into three components, i.e., the trend and cycle factor, the seasonal factor and the irregular factor based on a multiplicative model. The results of analyses strongly suggested that there existed a significant common pattern among the trend factors of doctors, radiographers and nurses. The similar phenomenon was also observed about the seasonal factors. Some specific cases of medical workers who received considerably high radiation doses were studied, and it was pointed out that, in order to lower the doses of medical workers, the factors which are peculiar to each medical facility must be precisely examined in addition to the strengthening of general radiological protective measures.

  18. EPA's Information Architecture and Web Taxonomy

    Science.gov (United States)

    EPA's Information Architecture creates a topical organization of our website, instead of an ownership-based organization. The EPA Web Taxonomy allows audiences easy access to relevant information from EPA programs, by using a common vocabulary.

  19. Developing regional weight-for-age growth references for malaria-endemic countries to optimize age-based dosing of antimalarials

    NARCIS (Netherlands)

    Hayes, Daniel J.; van Buuren, Stef; ter Kuile, Feiko O.; Stasinopoulos, D. Mikis; Rigby, Robert A.; Terlouw, Dianne J.

    2015-01-01

    To derive regional weight-for-age growth references to help optimize age-based dosing of antimalarials in Africa, the Americas, South-East Asia and the Western Pacific. A weight-for-age database was constructed from pre-existing population-based anthropometric data obtained from household surveys

  20. Comparison of the regulatory models assessing off-site radiological dose due to the routine releases of tritium

    International Nuclear Information System (INIS)

    Hwang, W. T.; Kim, E. H.; Han, M. H.; Choi, Y. H.; Lee, H. S.; Lee, C. W.

    2005-01-01

    Methodologies of NEWTRIT model, NRC model and AIRDOS-EPA model, which are off-site dose assessment models for regulatory compliance from routine releases of tritium into the environment, were investigated. Using the domestic data, if available, the predictive results of the models were compared. Among them, recently developed NEWTRIT model considers only doses from organically bounded tritium (OBT) due to environmental releases of tritiated water (HTO). A total dose from all exposure pathways predicted from AIRDOS-EPA model was 1.03 and 2.46 times higher than that from NEWTRIT model and NRC model, respectively. From above result, readers should not have an understanding that a predictive dose from NRC model may be underestimated compared with a realistic dose. It is because of that both mathematical models and corresponding parameter values for regulatory compliance are based on the conservative assumptions. For a dose by food consumption predicted from NEWTRIT model, the contribution of OBT was nearly equivalent to that of HTO due to relatively high consumption of grains in Korean. Although a total dose predicted from NEWTRIT model is similar to that from AIRDOS-EPA model, NEWTRIT model may be have a meaning in the understanding of phenomena for the behavior of HTO released into the environment

  1. Patient dose measurement and dose reduction in East Anglia (UK)

    International Nuclear Information System (INIS)

    Wade, J.P.; Goldstone, K.E.; Dendy, P.P.

    1995-01-01

    At the end of 1990 a programme of patient dose measurements was introduced as part of the quality assurance service already provided for X ray departments throughout the East Anglian Health Region (UK). Thermoluminescence dosemeters (TLDs) were used to measure over 1200 skin entrance surface doses for four common radiographic views in 33 hospitals in both the NHS and private sector. The four views were chosen to cover a wide range of equipment and techniques. The data collected have enabled Regional reference doses to be set which, for all views considered, fall below the National Radiological Protection Board (NRPB) Reference levels. In departments which exceeded reference levels, techniques were reviewed, improvements suggested and doses re-measured, in accordance with the recommended procedure for patient dose audit. A significant finding was that, given appropriate controls, X ray departments in the private sector could achieve the same acceptably low doses as NHS departments. (Author)

  2. US EPA Region 4 RMP Facilities

    Science.gov (United States)

    To improve public health and the environment, the United States Environmental Protection Agency (USEPA) collects information about facilities, sites, or places subject to environmental regulation or of environmental interest. Through the Geospatial Data Download Service, the public is now able to download the EPA Geodata shapefile containing facility and site information from EPA's national program systems. The file is Internet accessible from the Envirofacts Web site (http://www.epa.gov/enviro). The data may be used with geospatial mapping applications. (Note: The shapefile omits facilities without latitude/longitude coordinates.) The EPA Geospatial Data contains the name, location (latitude/longitude), and EPA program information about specific facilities and sites. In addition, the file contains a Uniform Resource Locator (URL), which allows mapping applications to present an option to users to access additional EPA data resources on a specific facility or site.

  3. New EPA ban stymies Canadian exports of PCB waste

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    With reference to a 1996 EPA ruling permitting the importation to the USA of PCBs for incineration, a unanimous three-judge panel of the US Court of Appeals for the Ninth District in San Francisco ruled that the Environmental Protection Agency (EPA) did not have the authority to permit the import of PCB wastes into the USA for disposal. Prior to the decision, 35 applications from Canada to export some 37,000 tonnes of PCB to the USA for disposal have been approved. Canadian brokers are upset with the decision, claiming that the decision will create a virtual monopoly for Bovar Inc., of Calgary, the only PCB-disposal facility in Canada. The loss (at least for the time being) of the alternate disposal opportunity will likely have the effect of forcing Canadian customers to pay more for PCB disposal. The Canadian government is monitoring the situation and is waiting to see whether an appeal is filed against the ruling

  4. A comparison of radiological risk assessment models: Risk assessment models used by the BEIR V Committee, UNSCEAR, ICRP, and EPA (for NESHAP)

    International Nuclear Information System (INIS)

    Wahl, L.E.

    1994-03-01

    Radiological risk assessments and resulting risk estimates have been developed by numerous national and international organizations, including the National Research Council's fifth Committee on the Biological Effects of Ionizing Radiations (BEIR V), the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), and the International Commission on Radiological Protection (ICRP). A fourth organization, the Environmental Protection Agency (EPA), has also performed a risk assessment as a basis for the National Emission Standards for Hazardous Air Pollutants (NESHAP). This paper compares the EPA's model of risk assessment with the models used by the BEIR V Committee, UNSCEAR, and ICRP. Comparison is made of the values chosen by each organization for several model parameters: populations used in studies and population transfer coefficients, dose-response curves and dose-rate effects, risk projection methods, and risk estimates. This comparison suggests that the EPA has based its risk assessment on outdated information and that the organization should consider adopting the method used by the BEIR V Committee, UNSCEAR, or ICRP

  5. Alanine dosimetry at NPL - the development of a mailed reference dosimetry service at radiotherapy dose levels

    International Nuclear Information System (INIS)

    Sharpe, P.H.G.; Sephton, J.P.

    1999-01-01

    In this paper we describe the work that has been carried out at National Physical Laboratory (NPL) to develop a mailed alanine reference dosimetry service for radiotherapy dose levels. The service is based on alanine/paraffin wax dosimeters produced at NPL. Using a data analysis technique based on spectrum fitting, it has been possible to achieve a precision of dose measurement better than ±0.05 Gy (1σ). A phantom set has been developed for use in high energy photon beams, which enables simultaneous irradiation of alanine dosimeters and ionisation chambers in a well defined geometry. Studies in photon beams of energies between 60 Co and 20 MeV have shown no significant energy dependence (<1%) for alanine relative to dose determination using a graphite calorimeter. Work is underway to extend the service to electron beams, and preliminary results are presented on the direct calibration of alanine in electron beams using a graphite calorimeter. (author)

  6. EPA scientific integrity policy draft

    Science.gov (United States)

    Showstack, Randy

    2011-08-01

    The U.S. Environmental Protection Agency (EPA) issued its draft scientific integrity policy on 5 August. The draft policy addresses scientific ethical standards, communications with the public, the use of advisory committees and peer review, and professional development. The draft policy was developed by an ad hoc group of EPA senior staff and scientists in response to a December 2010 memorandum on scientific integrity from the White House Office of Science and Technology Policy. The agency is accepting public comments on the draft through 6 September; comments should be sent to osa.staff@epa.gov. For more information, see http://www.epa.gov/stpc/pdfs/draft-scientific-integrity-policy-aug2011.pdf.

  7. US EPA overview

    International Nuclear Information System (INIS)

    Rowe, W.D.

    1976-01-01

    EPA believes that effective and efficient solutions to problems in all radioactive waste disposal areas will require close coordination and cooperation among all agencies involved. In this regard, EPA already has participated in meetings with the Energy Research and Development Administration, the Nuclear Regulatory Commission, the Council on Environmental Quality, the U.S. Geological Survey, and the Office of Management and Budget to lay the groundwork for the development of a consolidated national radioactive waste disposal plan. The EPA program is directed first toward developing goals and requirements; and then, in cooperation with the public, industry, the States and Federal agencies, towards determining by what means these goals can be achieved for each waste management option. In addition, the program will develop criteria for determining when the goals of the waste management options have been achieved. In summary, EPA will provide fundamental environmental criteria and generally applicable environmental standards for permanent disposal of high level radwastes. Concurrently, ERDA will develop the necessary technology; and NRC will conduct necessary studies, develop waste-related regulations, and license specific sites and methods of control. Together, we will be able to manage the disposal of the Nation's radioactive waste in an environmentally adequate manner

  8. EPA perspective on federal facility agreements

    International Nuclear Information System (INIS)

    Grundler, C.

    1988-01-01

    Although DOE's image with Congress and the media concerning environmental compliance may be poor, EPA sees the Department's recent attitude toward the environment as good. DOE and EPA must continue to move forward. In particular, EPA would like to emphasize less study of a problem and more clean-up. Strong, enforceable agreements will allow this goal to be met by letting EPA take more risks in its decision making. Currently EPA is developing an enforcement strategy for Federal facilities. This strategy will address identifying Federal facilities of concern, increasing enforcement and compliance monitoring activities at those facilities, implementing the model agreements, resource planning, and the establishment of an Agency Management System for Federal facilities. There are over 1000 Federal facilities which are listed on the EPA compliance docket. Over 200 Federal facilities are expected to be included on the NPL. Increased EPA attention may increase the ability of the various Federal agencies to obtain the necessary funding. Another subject being addressed by EPA is the liability of government contractors under the environmental statutes. The Agency is developing a GoCo enforcement strategy. In the hazardous waste enforcement program, three criteria are being considered for determining when to proceed against a contractor: Degree of contractor control over the hazardous waste management activity. Who is actually performing the work, and Degree of Departmental cooperation

  9. 77 FR 59758 - Idaho: Incorporation by Reference of Approved State Hazardous Waste Management Program

    Science.gov (United States)

    2012-10-01

    ...: Incorporation by Reference of Approved State Hazardous Waste Management Program AGENCY: Environmental Protection..., (RCRA), allows the Environmental Protection Agency (EPA) to authorize State hazardous waste management... codification of the authorized Idaho hazardous waste management program and incorporates by reference...

  10. Transatlantic Comparison of CT Radiation Doses in the Era of Radiation Dose-Tracking Software.

    Science.gov (United States)

    Parakh, Anushri; Euler, Andre; Szucs-Farkas, Zsolt; Schindera, Sebastian T

    2017-12-01

    The purpose of this study is to compare diagnostic reference levels from a local European CT dose registry, using radiation-tracking software from a large patient sample, with preexisting European and North American diagnostic reference levels. Data (n = 43,761 CT scans obtained over the course of 2 years) for the European local CT dose registry were obtained from eight CT scanners at six institutions. Means, medians, and interquartile ranges of volumetric CT dose index (CTDI vol ), dose-length product (DLP), size-specific dose estimate, and effective dose values for CT examinations of the head, paranasal sinuses, thorax, pulmonary angiogram, abdomen-pelvis, renal-colic, thorax-abdomen-pelvis, and thoracoabdominal angiogram were obtained using radiation-tracking software. Metrics from this registry were compared with diagnostic reference levels from Canada and California (published in 2015), the American College of Radiology (ACR) dose index registry (2015), and national diagnostic reference levels from local CT dose registries in Switzerland (2010), the United Kingdom (2011), and Portugal (2015). Our local registry had a lower 75th percentile CTDI vol for all protocols than did the individual internationally sourced data. Compared with our study, the ACR dose index registry had higher 75th percentile CTDI vol values by 55% for head, 240% for thorax, 28% for abdomen-pelvis, 42% for thorax-abdomen-pelvis, 128% for pulmonary angiogram, 138% for renal-colic, and 58% for paranasal sinus studies. Our local registry had lower diagnostic reference level values than did existing European and North American diagnostic reference levels. Automated radiation-tracking software could be used to establish and update existing diagnostic reference levels because they are capable of analyzing large datasets meaningfully.

  11. Establishment of institutional diagnostic reference level for computed tomography with automated dose-tracking software.

    Science.gov (United States)

    Liang, Chong R; Chen, Priscilla X H; Kapur, Jeevesh; Ong, Michael K L; Quek, Swee T; Kapur, Subhash C

    2017-06-01

    The aim of this study was to establish institutional diagnostic reference levels (DRLs) by summarising doses collected across the five computed tomography (CT) system in our institution. CT dose data of 15940 patients were collected retrospectively from May 2015 to October 2015 in five institutional scanners. The mean, 75th percentile and 90th percentile of the dose spread were calculated according to anatomic region. The common CT examinations such as head, chest, combined abdomen/pelvis (A/P), and combined chest/abdomen/pelvis (C/A/P) were reviewed. Distribution of CT dose index (CTDIvol), dose-length product (DLP) and effective dose (ED) were extracted from the data for single-phasic and multiphasic examinations. The institutional DRL for our CT units were established as mean (50th percentile) of CTDIvol (mGy), DLP (mGy.cm) and ED (mSv) for single and multiphasic studies using the dose-tracking software. In single phasic examination, Head: (49.0 mGy), (978.0 mGy.cm), (2.4 mSv) respectively; Chest: (6.0 mGy), (254.0 mGy.cm), (4.9 mSv) respectively; CT A/P (10.0 mGy), (514.0 mGy.cm), (8.9 mSv) respectively; CT C/A/P (10.0 mGy), (674.0 mGy.cm), (11.8 mSv) respectively. In multiphasic studies: Head (45.0 mGy), (1822.0 mGy.cm), (5.0 mSv) respectively; Chest (8.0 mGy), (577.0 mGy.cm), (10.0 mSv) respectively; CT A/P: (10.0 mGy), (1153.0 mGy.cm), (20.2 mSv) respectively; CT C/A/P: (11.0 mGy), (1090.0 mGy.cm), (19.2 mSv) respectively. The reported metrics offer a variety of information that institutions can use for quality improvement activities. The variations in dose between scanners suggest a large potential for optimisation of radiation dose. © 2017 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.

  12. Open Letter from the GAC-EPA to the Chairman of the PFGB EPA

    CERN Multimedia

    GAC-EPA

    2012-01-01

    Following the publication by the Chairman of the Pension Fund Governing Board of  the Spring report of the Pension Fund in the CERN Bulletin issue dated 25 July 2012 (Nos 30 & 31), the GAC-EPA has reacted through an open letter. See www.gac-epa.org under Announcement.

  13. Cheminformatics Analysis of EPA ToxCast Chemical Libraries ...

    Science.gov (United States)

    An important goal of toxicology research is the development of robust methods that use in vitro and chemical structure information to predict in vivo toxicity endpoints. The US EPA ToxCast program is addressing this goal using ~600 in vitro assays to create bioactivity profiles on a set of 320 compounds, mostly pesticide actives, that have well characterized in vivo toxicity. These 320 compounds (EPA-320 set evaluated in Phase I of ToxCast) are a subset of a much larger set of ~10,000 candidates that are of interest to the EPA (called here EPA-10K). Predictive models of in vivo toxicity are being constructed from the in vitro assay data on the EPA-320 chemical set. These models require validation on additional chemicals prior to wide acceptance, and this will be carried out by evaluating compounds from EPA-10K in Phase II of ToxCast. We have used cheminformatics approaches including clustering, data visualization, and QSAR to develop models for EPA-320 that could help prioritizing EPA-10K validation chemicals. Both chemical descriptors, as well as calculated physicochemical properties have been used. Compounds from EPA-10K are prioritized based on their similarity to EPA-320 using different similarity metrics, with similarity thresholds defining the domain of applicability for the predictive models built for EPA-320 set. In addition, prioritized lists of compounds of increasing dissimilarity from the EPA-320 have been produced, to test the ability of the EPA-320

  14. EPA Communications Stylebook: Writing Guide

    Science.gov (United States)

    For the most part, EPA follows the Associated Press (AP) Stylebook. Other requirements of basic punctuation and grammar and usage in EPA writing modify, supplement, or in some cases reiterate AP style.

  15. Developing patient-specific dose protocols for a CT scanner and exam using diagnostic reference levels

    International Nuclear Information System (INIS)

    Strauss, Keith J.

    2014-01-01

    The management of image quality and radiation dose during pediatric CT scanning is dependent on how well one manages the radiographic techniques as a function of the type of exam, type of CT scanner, and patient size. The CT scanner's display of expected CT dose index volume (CTDI vol ) after the projection scan provides the operator with a powerful tool prior to the patient scan to identify and manage appropriate CT techniques, provided the department has established appropriate diagnostic reference levels (DRLs). This paper provides a step-by-step process that allows the development of DRLs as a function of type of exam, of actual patient size and of the individual radiation output of each CT scanner in a department. Abdomen, pelvis, thorax and head scans are addressed. Patient sizes from newborns to large adults are discussed. The method addresses every CT scanner regardless of vendor, model or vintage. We cover adjustments to techniques to manage the impact of iterative reconstruction and provide a method to handle all available voltages other than 120 kV. This level of management of CT techniques is necessary to properly monitor radiation dose and image quality during pediatric CT scans. (orig.)

  16. Modeling a point-source release of 1,1,1-trichloroethane using EPA's SCREEN model

    International Nuclear Information System (INIS)

    Henriques, W.D.; Dixon, K.R.

    1994-01-01

    Using data from the Environmental Protection Agency's Toxic Release Inventory 1988 (EPA TRI88), pollutant concentration estimates were modeled for a point source air release of 1,1,1-trichloroethane at the Savannah River Plant located in Aiken, South Carolina. Estimates were calculating using the EPA's SCREEN model utilizing typical meteorological conditions to determine maximum impact of the plume under different mixing conditions for locations within 100 meters of the stack. Input data for the SCREEN model were then manipulated to simulate the impact of the release under urban conditions (for the purpose of assessing future landuse considerations) and under flare release options to determine if these parameters lessen or increase the probability of human or wildlife exposure to significant concentrations. The results were then compared to EPA reference concentrations (RfC) in order to assess the size of the buffer around the stack which may potentially have levels that exceed this level of safety

  17. Comparison of doses, before and after remedial action

    International Nuclear Information System (INIS)

    Wallo, A. III

    1988-01-01

    The Division of Facility and Site Decommissioning Projects at DOE-Headquarters is evaluating potential doses from vicinity properties before and after remedial action at several sites using the RESRAD computer code. A preliminary review was completed for nineteen Colonie vicinity properties. This review indicated potential doses before remedial action at these sites ranged from about 43 to 2 mrem/year and after remediation between 5 and 0 mrem/year. These estimates indicate the conservatism in the DOE-derived soil decontamination remedial action. Following remedial action, the potential doses are on the order of those being considered to be below regulatory concern by EPA and NRC. The estimates made for these sites are still conservative due to the method used to determine the source term. More realistic assessments of source terms are anticipate dot significantly affect the after-remedial-action doses, possibly lowering them all to below 1 mrem/year. This evaluation is being refined with more realistic estimates of the source term, for all of the Colonie vicinity properties. Once the Colonie vicinity properties are completed, at least three other sites will be evaluated. It is hoped that this information will provide added confidence in the remedial action guidelines and more general acceptance of the guidelines by the EPA and others

  18. Radiation dose estimates due to air particulate emissions from selected phosphate industry operations

    International Nuclear Information System (INIS)

    Partridge, J.E.; Horton, T.R.; Sensintaffar, E.L.; Boysen, G.A.

    1978-06-01

    The EPA Office of Radiation Programs has conducted a series of studies to determine the radiological impact of the phosphate mining and milling industry. This report describes the efforts to estimate the radiation doses due to airborne emissions of particulates from selected phosphate milling operations in Florida. Two wet process phosphoric acid plants and one ore drying facility were selected for this study. The 1976 Annual Operations/Emissions Report, submitted by each facility to the Florida Department of Environmental Regulation, and a field survey trip by EPA personnel to each facility were used to develop data for dose calculations. The field survey trip included sampling for stack emissions and ambient air samples collected in the general vicinity of each plant. Population and individual radiation dose estimates are made based on these sources of data

  19. EPA Alternative Dispute Resolution Contacts

    Science.gov (United States)

    The success of EPA's ADR efforts depends on a network of talented and experienced professionals in Headquarters offices and EPA Regions. For Agency-wide ADR information, please contact the Conflict Prevention and Resolution Center.

  20. Transforming an EPA QA/R-2 quality management plan into an ISO 9002 quality management system.

    Science.gov (United States)

    Kell, R A; Hedin, C M; Kassakhian, G H; Reynolds, E S

    2001-01-01

    The Environmental Protection Agency's (EPA) Office of Emergency and Remedial Response (OERR) requires environmental data of known quality to support Superfund hazardous waste site projects. The Quality Assurance Technical Support (QATS) Program is operated by Shaw Environmental and Infrastructure, Inc. to provide EPA's Analytical Operations Center (AOC) with performance evaluation samples, reference materials, on-site laboratory auditing capabilities, data audits (including electronic media data audits), methods development, and other support services. The new QATS contract awarded in November 2000 required that the QATS Program become ISO 9000 certified. In a first for an EPA contractor, the QATS staff and management successfully transformed EPA's QA/R-2 type Quality Management Plan into a Quality Management System (QMS) that complies with the requirements of the internationally recognized ISO 9002 standard and achieved certification in the United States, Canada, and throughout Europe. The presentation describes how quality system elements of ISO 9002 were implemented on an already existing quality system. The psychological and organizational challenges of the culture change in QATS' day-to-day operations will be discussed for the benefit of other ISO 9000 aspirants.

  1. Calculation of normalised organ and effective doses to adult reference computational phantoms from contemporary computed tomography scanners

    International Nuclear Information System (INIS)

    Jansen, Jan T.M.; Shrimpton, Paul C.

    2010-01-01

    The general-purpose Monte Carlo radiation transport code MCNPX has been used to simulate photon transport and energy deposition in anthropomorphic phantoms due to the x-ray exposure from the Philips iCT 256 and Siemens Definition CT scanners, together with the previously studied General Electric 9800. The MCNPX code was compiled with the Intel FORTRAN compiler and run on a Linux PC cluster. A patch has been successfully applied to reduce computing times by about 4%. The International Commission on Radiological Protection (ICRP) has recently published the Adult Male (AM) and Adult Female (AF) reference computational voxel phantoms as successors to the Medical Internal Radiation Dose (MIRD) stylised hermaphrodite mathematical phantoms that form the basis for the widely-used ImPACT CT dosimetry tool. Comparisons of normalised organ and effective doses calculated for a range of scanner operating conditions have demonstrated significant differences in results (in excess of 30%) between the voxel and mathematical phantoms as a result of variations in anatomy. These analyses illustrate the significant influence of choice of phantom on normalised organ doses and the need for standardisation to facilitate comparisons of dose. Further such dose simulations are needed in order to update the ImPACT CT Patient Dosimetry spreadsheet for contemporary CT practice. (author)

  2. Categorical Regression and Benchmark Dose Software 3.0

    Science.gov (United States)

    The objective of this full-day course is to provide participants with interactive training on the use of the U.S. Environmental Protection Agency’s (EPA) Benchmark Dose software (BMDS, version 3.0, released fall 2018) and Categorical Regression software (CatReg, version 3.1...

  3. Eicosapentaenoic acid (EPA) induced apoptosis in HepG2 cells through ROS–Ca{sup 2+}–JNK mitochondrial pathways

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yuanyuan; Han, Lirong [Key Laboratory of Food Nutrition and Safety, Ministry of Education, College of Food Engineering and Biotechnology, Tianjin University of Science and Technology, No. 29, 13th Avenue, Tianjin Economy Technological Development Area, Tianjin 300457 (China); Qi, Wentao [Academy of State Administration of Grain, No.11 Baiwanzhuang Avenue, Xicheng District, Beijing, 100037 (China); Cheng, Dai; Ma, Xiaolei; Hou, Lihua [Key Laboratory of Food Nutrition and Safety, Ministry of Education, College of Food Engineering and Biotechnology, Tianjin University of Science and Technology, No. 29, 13th Avenue, Tianjin Economy Technological Development Area, Tianjin 300457 (China); Cao, Xiaohong, E-mail: caoxh@tust.edu.cn [Key Laboratory of Food Nutrition and Safety, Ministry of Education, College of Food Engineering and Biotechnology, Tianjin University of Science and Technology, No. 29, 13th Avenue, Tianjin Economy Technological Development Area, Tianjin 300457 (China); Wang, Chunling, E-mail: wangchunling@tust.edu.cn [Key Laboratory of Food Nutrition and Safety, Ministry of Education, College of Food Engineering and Biotechnology, Tianjin University of Science and Technology, No. 29, 13th Avenue, Tianjin Economy Technological Development Area, Tianjin 300457 (China)

    2015-01-24

    Highlights: • EPA evoked ROS formation, [Ca{sup 2+}]{sub c} accumulation, the opening of MPTP and the phosphorylation of JNK. • EPA-induced [Ca{sup 2+}]{sub c} elevation was depended on production of ROS. • EPA-induced ROS generation, [Ca{sup 2+}]{sub c} increase, and JNK activated caused MPTP opening. • The apoptosis induced by EPA was related to release of cytochrome C through the MPTP. • EPA induced HepG2 cells apoptosis through ROS–Ca{sup 2+}–JNK mitochondrial pathways. - Abstract: Eicosapentaenoic acid (EPA), a well-known dietary n−3 PUFAS, has been considered to inhibit proliferation of tumor cells. However, the molecular mechanism related to EPA-induced liver cancer cells apoptosis has not been reported. In this study, we investigated the effect of EPA on HepG2 cells proliferation and apoptosis mechanism through mitochondrial pathways. EPA inhibited proliferation of HepG2 cells in a dose-dependent manner and had no significant effect on the cell viability of humor normal liver L-02 cells. It was found that EPA initially evoked ROS formation, leading to [Ca{sup 2+}]{sub c} accumulation and the mitochondrial permeability transition pore (MPTP) opening; EPA-induced HepG2 cells apoptosis was inhibited by N-acetylcysteine (NAC, an inhibitor of ROS), 1,2-bis (2-aminophenoxy) ethane-N,N,N′,N′-tetraacetic acid (BAPTA-AM, a chelator of calcium) and CsA (inhibitor of MPTP). The relationship between ROS production, the increase of cytoplasmic Ca and MPTP opening was detected. It seems that ROS may act as an upstream regulator of EPA-induced [Ca{sup 2+}]{sub c} generation, moreover, generation of ROS, overload of mitochondrial [Ca{sup 2+}]{sub c}, and JNK activated cause the opening of MPTP. Western blotting results showed that EPA elevated the phosphorylation status of JNK, processes associated with the ROS generation. Simultaneously, the apoptosis induced by EPA was related to release of cytochrome C from mitochondria to cytoplasm through the MPTP

  4. Reference Japanese man

    International Nuclear Information System (INIS)

    Tanaka, Giichiro

    1985-01-01

    To make real and accurate dose assessment method so far, it is necessitated to provide ''Reference Japanese Man'' based on anotomical, physiological and biochemical data of Japanese people instead of the Reference Man presented in ICRP Publications 23 and 30. This review describes present status of researched for the purpose of establishing of Reference Japanese Man. The Reference Japanese Man is defined as a male or female adult who lives in Japan with a Japanese life-style and food custom. His stature and body weight, and the other data was decided as mean values of male or female people of Japan. As for food custom, Japanese people take significantly smaller amount of meat and milk products than Western people, while larger intake amount of cereals and marine products such as fish or seaweeds. Weight of organs is a principal factor for internal dose assessment and mean values for living Japanese adult has been investigated and the value employable for dose assessment for organs and tissues are shown. To employ these values of Reference Japanese Man, it should be taken into account of age. Metabolic parameters should also be considered. Iodine metabolism in Japanese is quite different from that of Western people. The above-mentioned data are now tentatively employing in modification of table of MIRD method and others. (Takagi, S.)

  5. Electron-Positron Accumulator (EPA)

    CERN Multimedia

    Photographic Service

    1986-01-01

    After acceleration in the low-current linac LIL-W, the electrons and positrons are accumulated in EPA to obtain a sufficient intensity and a suitable time-structure, before being passed on to the PS for further acceleration to 3.5 GeV. Electrons circulate from right to left, positrons in the other direction. Dipole bending magnets are red, focusing quadrupoles blue, sextupoles for chromaticity-control orange. The vertical tube at the left of the picture belongs to an optical transport system carrying the synchrotron radiation to detectors for beam size measurement. Construction of EPA was completed in spring 1986. LIL-W and EPA were conceived for an energy of 600 MeV, but operation was limited to 500 MeV.

  6. The role of the EPA radiation quality assurance program in the measurement quality assurance accreditation program for radioassay laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Grady, T.M. [Environmental Monitoring Systems Laboratory, Las Vegas, NV (United States)

    1993-12-31

    As the nature and extent of radiological contamination becomes better documented and more public, radioanalytical laboratories are faced with a constantly expanding variety of new and difficult analytical requirements. Concurrent with those requirements is the responsibility to provide customers, regulatory officials, or the public with defensible data produced in an environment of verifiable, controlled quality. To meet that need, a quality assurance accreditation program for radioassay laboratories has been proposed by the American National Standards Institute (ANSI). The standard will provide the organizational framework and functional requirements needed to assure the quality of laboratory outputs. Under the proposed program, the U.S. Environmental Protection Agency`s (EPA`s) Laboratory Intercomparison Program plays a key role as a reference laboratory. The current and proposed roles of the EPA Intercomparison Program are discussed, as are the functional relationships between EPA, the accreditating organization, and the service and monitoring laboratories.

  7. Evidence of dose saving in routine CT practice using iterative reconstruction derived from a national diagnostic reference level survey.

    Science.gov (United States)

    Thomas, P; Hayton, A; Beveridge, T; Marks, P; Wallace, A

    2015-09-01

    To assess the influence and significance of the use of iterative reconstruction (IR) algorithms on patient dose in CT in Australia. We examined survey data submitted to the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) National Diagnostic Reference Level Service (NDRLS) during 2013 and 2014. We compared median survey dose metrics with categorization by scan region and use of IR. The use of IR results in a reduction in volume CT dose index of between 17% and 44% and a reduction in dose-length product of between 14% and 34% depending on the specific scan region. The reduction was highly significant (p sum test) for all six scan regions included in the NDRLS. Overall, 69% (806/1167) of surveys included in the analysis used IR. The use of IR in CT is achieving dose savings of 20-30% in routine practice in Australia. IR appears to be widely used by participants in the ARPANSA NDRLS with approximately 70% of surveys submitted employing this technique. This study examines the impact of the use of IR on patient dose in CT on a national scale.

  8. Rapid radiological characterization method based on the use of dose coefficients

    International Nuclear Information System (INIS)

    Dulama, C.; Toma, Al.; Dobrin, R.; Valeca, M.

    2010-01-01

    Intervention actions in case of radiological emergencies and exploratory radiological surveys require rapid methods for the evaluation of the range and extent of contamination. When simple and homogeneous radionuclide composition characterize the radioactive contamination, surrogate measurements can be used to reduce the costs implied by laboratory analyses and to speed-up the process of decision support. A dose-rate measurement-based methodology can be used in conjunction with adequate dose coefficients to assess radionuclide inventories and to calculate dose projections for various intervention scenarios. The paper presents the results obtained for dose coefficients in some particular exposure geometries and the methodology used for deriving dose rate guidelines from activity concentration upper levels specified as contamination limits. All calculations were performed by using the commercial software MicroShield from Grove Software Inc. A test case was selected as to meet the conditions from EPA Federal Guidance Report no. 12 (FGR12) concerning the evaluation of dose coefficients for external exposure from contaminated soil and the obtained results were compared to values given in the referred document. The geometries considered as test cases are: contaminated ground surface; - infinite extended homogeneous surface contamination and soil contaminated to a depth of 15 cm. As shown by the results, the values agree within 50% relative difference for most of the cases. The greatest discrepancies were observed for depth contamination simulation and in the case of radionuclides with complicated gamma emission and this is due to the different approach from MicroShield and FGR12. A case study is presented for validation of the methodology, where both dose rate measurements and laboratory analyses were performed on an extended quasi-homogeneous NORM contamination. The dose rate estimations obtained by applying the dose coefficients to the radionuclide concentrations

  9. Comparative Analysis of EPA/DHA-PL Forage and Liposomes in Orotic Acid-Induced Nonalcoholic Fatty Liver Rats and Their Related Mechanisms.

    Science.gov (United States)

    Chang, Mengru; Zhang, Tiantian; Han, Xiuqing; Tang, Qingjuan; Yanagita, Teruyoshi; Xu, Jie; Xue, Changhu; Wang, Yuming

    2018-02-14

    Nonalcoholic fatty liver disease (NAFLD) has become one predictive factor of death from various illnesses. The present study was to comparatively investigate the effects of eicosapentaenoic acid-enriched and docosahexaenoic acid-enriched phospholipids forage (EPA-PL and DHA-PL) and liposomes (lipo-EPA and lipo-DHA) on NAFLD and demonstrate the possible protective mechanisms involved. The additive doses of EPA-PL and DHA-PL in all treatment groups were 1% of total diets, respectively. The results showed that Lipo-EPA could significantly improve hepatic function by down-regulating orotic acid-induced serum aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels by 55.6% and 34.2%, respectively (p DHA could also significantly suppress hepatic lipid accumulation mainly by enhancement of hepatic lipolysis and cholesterol efflux. Furthermore, DHA-PL played a certain role in inhibiting hepatic lipogenesis and accelerating cholesterol efflux. The results obtained in this work might contribute to the understanding of the biological activities of EPA/DHA-PL and liposomes and further investigation on its potential application values for food supplements.

  10. EPA Metadata Style Guide Keywords and EPA Organization Names

    Science.gov (United States)

    The following keywords and EPA organization names listed below, along with EPA’s Metadata Style Guide, are intended to provide suggestions and guidance to assist with the standardization of metadata records.

  11. A review of data on the effects of low and low dose-rate radiation with special reference to the dose limit problem

    International Nuclear Information System (INIS)

    Matsudaira, Hiromichi

    1977-01-01

    This is a review of data pertaining to detection and quantification of the effects after exposure to low LET radiations delivered at low and low dose-rate, i.e., at a level of maximum permissible dose for the radiation workers, on experimental materials ranging from plant to rodents and on some human populations. Irradiation at a dose of a few rad is reported to induce mutation or malignant transformation in some selected model systems, with a linear dose-effect relationship. Moreover, the incidence of the chromosome aberrations in spermatocytes is reported to be elevated in the scorpiones (Tityus bahiensis) collected in a region of high natural background radiations (several rem/year). An increase in the incidence of childhood malignancies is reported among children exposed in utero to diagnostic X-rays. Appreciable increase in the incidence of genetic diseases due possibly to chromosome aberrations is also reported among population living in a region of high natural background radiations. Points are raised and discussed as to the interpretation and particularly application of these data to the estimation of somatic and genetic risks of human population from man-made radiations. Recent attempts of risk-benefit analysis with populations subjected to mass X-ray examination of the chest and stomac are referred to. Since we are unaware of the actual injuries due to the exposure even at the level of radiation workers (5 rem/year), it is out of the capacity of a biologist to afford the basis for the decision of limiting the exposure of general population due to the light water reactor operation to 5 mrem/year. (auth.)

  12. Dose limits, constraints, reference levels. What does it mean for radiation protection?; Grenzwerte, Richtwerte, Referenzwerte. Was bedeutet das fuer den Strahlenschutz

    Energy Technology Data Exchange (ETDEWEB)

    Breckow, J. [Technische Hochschule Mittelhessen (THM), Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz (IMPS)

    2016-07-01

    The established concept of radiation protection with its basic principles justification, optimization, and limitation has proved its value and is going to be continued. In its deeper meaning, however, the concept is rather subtle and complex. Furthermore, in some aspects there remain some breaches or inconsistencies. This is just true for the terms dose limit, reference lever, and constraint that are tightly associated with the radiation protection principles. In order to guarantee the ability of radiation protection in whole extent, the subtle differences of meaning have to be communicated. There is a permanent need to defend the conceptual function of these terms against deliberate or undeliberate misinterpretations. Reference levels are definitely not the same as dose limits and they may not be misused as such. Any attempt to misinterpret fundamental radiation protection principles for selfish purposes should discouraged vigorously.

  13. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 1er novembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel La permanence suivante aura lieu le mardi 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php  

  14. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 28 novembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  15. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 30 mai de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  16. EPA Region 1 Environmentally Sensitive Areas

    Data.gov (United States)

    U.S. Environmental Protection Agency — This coverage represents polygon equivalents of environmentally sensitive areas (ESA) in EPA Region I. ESAs were developed as part of an EPA headquarters initiative...

  17. Construction of Chinese reference female phantom

    International Nuclear Information System (INIS)

    Sheng Yinxiangzi; Liu Lixing; Xia Xiaobin

    2013-01-01

    In this study, a Voxel-based Chinese Reference female Phantom (VCRP-woman) is developed from an individual female phantom which was based on high resolution cross-sectional color photographs. An in-house C ++ program was developed to adjust the phantom. Finally, a reference female phantom with have the same height, weighte and similar organs masses with the Chinese reference adult female data. The adjusted phantom is then imported to MCNPX to calculate the organs absorbed dose and effective dose conversion coefficients. Results are compared between VCRP-woman and the ICRP adult reference female phantom. (authors)

  18. Dose coefficients for public exposition; Coeficientes de dose para exposicao ao publico

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This Regulation refers to the requirements of the Regulation CNEN-NN.3.01 'Basic Guidelines for Radiation Protection', to be applied to the dose calculus with the objective of verification according to the limits and restrictions of dose and reference levels of the public individuals, expressed in its section 5

  19. U.S. EPA Metadata Editor (EME)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA Metadata Editor (EME) allows users to create geospatial metadata that meets EPA's requirements. The tool has been developed as a desktop application that...

  20. EPA Facility Registry System (FRS): NCES

    Science.gov (United States)

    This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link to the National Center for Education Statistics (NCES). The primary federal database for collecting and analyzing data related to education in the United States and other Nations, NCES is located in the U.S. Department of Education, within the Institute of Education Sciences. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA00e2??s national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to NCES school facilities once the NCES data has been integrated into the FRS database. Additional information on FRS is available at the EPA website http://www.epa.gov/enviro/html/fii/index.html.

  1. 2011 EPA Pesticide General Permit (PGP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The 2011 EPA Pesticide General Permit (PGP) covers discharges of biological pesticides, and chemical pesticides that leave a residue, in areas where EPA is the NPDES...

  2. Modelling of Biota Dose Effects. Report of Working Group 6 Biota Dose Effects Modelling of EMRAS II Topical Heading Reference Approaches for Biota Dose Assessment. Environmental Modelling for RAdiation Safety (EMRAS II) Programme

    International Nuclear Information System (INIS)

    2014-07-01

    Environmental assessment models are used for evaluating the radiological impact of actual and potential releases of radionuclides to the environment. They are essential tools for use in the regulatory control of routine discharges to the environment and in planning the measures to be taken in the event of accidental releases. They are also used for predicting the impact of releases which may occur far into the future, for example, from underground radioactive waste repositories. It is important to verify, to the extent possible, the reliability of the predictions of such models by a comparison with measured values in the environment or with the predictions of other models. The IAEA has been organizing programmes on international model testing since the 1980s. These programmes have contributed to a general improvement in models, in the transfer of data and in the capabilities of modellers in Member States. IAEA publications on this subject over the past three decades demonstrate the comprehensive nature of the programmes and record the associated advances which have been made. From 2009 to 2011, the IAEA organized a project entitled Environmental Modelling for RAdiation Safety (EMRAS II), which concentrated on the improvement of environmental transfer models and the development of reference approaches to estimate the radiological impacts on humans, as well as on flora and fauna, arising from radionuclides in the environment. Different aspects were addressed by nine working groups covering three themes: reference approaches for human dose assessment, reference approaches for biota dose assessment and approaches for addressing emergency situations. This publication describes the work of the Biota Effects Modelling Working Group

  3. Modelling of Biota Dose Effects. Report of Working Group 6 Biota Dose Effects Modelling of EMRAS II Topical Heading Reference Approaches for Biota Dose Assessment. Environmental Modelling for RAdiation Safety (EMRAS II) Programme

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-07-15

    Environmental assessment models are used for evaluating the radiological impact of actual and potential releases of radionuclides to the environment. They are essential tools for use in the regulatory control of routine discharges to the environment and in planning the measures to be taken in the event of accidental releases. They are also used for predicting the impact of releases which may occur far into the future, for example, from underground radioactive waste repositories. It is important to verify, to the extent possible, the reliability of the predictions of such models by a comparison with measured values in the environment or with the predictions of other models. The IAEA has been organizing programmes on international model testing since the 1980s. These programmes have contributed to a general improvement in models, in the transfer of data and in the capabilities of modellers in Member States. IAEA publications on this subject over the past three decades demonstrate the comprehensive nature of the programmes and record the associated advances which have been made. From 2009 to 2011, the IAEA organized a project entitled Environmental Modelling for RAdiation Safety (EMRAS II), which concentrated on the improvement of environmental transfer models and the development of reference approaches to estimate the radiological impacts on humans, as well as on flora and fauna, arising from radionuclides in the environment. Different aspects were addressed by nine working groups covering three themes: reference approaches for human dose assessment, reference approaches for biota dose assessment and approaches for addressing emergency situations. This publication describes the work of the Biota Effects Modelling Working Group.

  4. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 31 octobre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel La permanence suivante aura lieu le mardi 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  5. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 29 août de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php  

  6. Purchasing Supplies, Equipment and Services Under EPA Grants

    Science.gov (United States)

    EPA developed this guidance to help ensure you meet EPA requirements when making such necessary purchases. With very few exceptions, you must follow a competitive process when you use EPA grant funds to acquire equipment and professional services.

  7. EPA Environmental Chemistry Laboratory

    Science.gov (United States)

    1993-01-01

    The Environmental Protection Agency's (EPA) Chemistry Laboratory (ECL) is a national program laboratory specializing in residue chemistry analysis under the jurisdiction of the EPA's Office of Pesticide Programs in Washington, D.C. At Stennis Space Center, the laboratory's work supports many federal anti-pollution laws. The laboratory analyzes environmental and human samples to determine the presence and amount of agricultural chemicals and related substances. Pictured, ECL chemists analyze environmental and human samples for the presence of pesticides and other pollutants.

  8. Notification: EPA's Preparedness and Response Efforts to the 2017 Hurricanes in EPA Regions 2, 4 and 6

    Science.gov (United States)

    Project #OPE-FY18-0005, December 13, 2017. The EPA OIG plans to begin preliminary research on the EPA’s preparedness and response efforts to the 2017 hurricanes that impacted EPA Regions 2, 4 and 6.

  9. EFSA NDA Panel (EFSA Panel on Dietetic Products, Nutrition and Allergies), 2014. Scientific Opinion on the extension of use for DHA and EPA-rich algal oil from Schizochytrium sp. as a Novel Food ingredient

    DEFF Research Database (Denmark)

    Tetens, Inge; Poulsen, Morten

    2014-01-01

    Following a request from the European Commission, the EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA) was asked to deliver a scientific opinion on an extension of use for docosahexaenoic acid (DHA) and eicosapentaenoic acid (EPA)-rich algal oil from Schizochytrium sp. as a novel food...... population, excluding pregnant and lactating women. In a previous opinion on the Tolerable Upper Intake Level of EPA, DHA and docosapentaenoic acid (DPA), the Panel concluded that supplemental intake of EPA and DHA combined at doses up to 5 g/day, does not give rise to safety concerns for adults. Based...... ingredient (NFI) in the context of Regulation (EC) No 258/97. The NFI is already authorised for use in a range of foodstuffs at specified maximum levels. The applicant requests an extension of use of the NFI in food supplements up to a maximum DHA and EPA content of 3 g per daily dose for the adult...

  10. EPA Regulation of Bed Bug Pesticides

    Science.gov (United States)

    All pesticides must be registered by EPA before being sold and used in the U.S., other than those that rely on a limited set of active ingredients (so-called minimum risk pesticides). EPA reviews for safety and effectiveness.

  11. Comparative study of reference points by dosimetric analyses for late complications after uniform external radiotherapy and high-dose-rate brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Chen, S.-W.; Liang, J.-A.; Yeh, L.-S.; Yang, S.-N.; Shiau, A.-C.; Lin, F.-J.

    2004-01-01

    Purpose: This study aimed to correlate and compare the predictive values of rectal and bladder reference doses of uniform external beam radiotherapy without shielding and high-dose-rate intracavitary brachytherapy (HDRICB) with late sequelae in patients with uterine cervical cancer. Methods and materials: Between September 1992 and December 1998, 154 patients who survived more than 12 months after treatment were studied. Initially, they were treated with 10-MV X-rays (44 to 45 Gy/22 to 25 fractions over 4 to 5 weeks) to the whole pelvis, after which HDRICB was performed using 192 Ir remote afterloading at 1-week intervals for 4 weeks. The standard prescribed dose for each HDRICB was 6.0 Gy to point A. Patient- and treatment-related-factors were evaluated for late rectal complications using logistic regression modeling. Results: The probability of rectal complications showed better correlation of dose-response with increasing total ICRU (International Committee on Radiotherapy Units and Measurements) rectal dose. Multivariate logistic regression demonstrated a high risk of late rectal sequelae in patients who developed rectal complications (p 0.0001;relative risk, 15.06;95% CI, 2.89∼43.7) and total ICRU rectal dose greater than 16 Gy (p = 0.02;relative risk, 2.07;95% CI, 1.13∼4.55). The high risk factors for bladder complications were seen in patients who developed rectal complications (p = 0.0001;relative risk, 15.2;95% CI, 2.81∼44.9) and total ICRU bladder dose greater than 24 Gy (p = 0.02;relative risk, 8.93;95% CI, 1.79∼33.1). Conclusion: This study demonstrated the predictive value of ICRU rectal and bladder reference dosing in HDRICB for patients receiving uniform external beam radiation therapy without central shielding. Patients who had a total ICRU rectal dose greater than 16 Gy, or a total ICRU bladder dose over 24 Gy, were at risk of late sequelae

  12. EPA Office Points, Tutuila AS, 2009, US EPA Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA office location in Tutila Island in American Samoa. American Samoa is an unincorporated and unorganized territory of the United States, and administered by...

  13. Efficacy of Ballast Water Treatment Systems: A Report by the EPA Science Advisory Board

    Science.gov (United States)

    2011-07-12

    followed during testing, are needed. In addition, the EPA 3 Protists refers to various one-celled...should develop metrics and methods appropriate for compliance monitoring and enforcement as soon as possible. Limits for selected protists < 10 µm...as “ protist -sized” organisms, or organisms ≥10 µm and < 50 µm in minimum dimension), and the ETV Protocol provides examples with a more stringent

  14. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 26 septembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  15. Proposals for common definitions of reference points in gynecological brachytherapy

    International Nuclear Information System (INIS)

    Chassagne, D.; Horiot, J.C.

    1977-01-01

    In May 1975 the report of European Curietherapy Group recommended in gynecological Dosimetry by computer. Use of reference points = lymphatic trapezoid figure with 6 points, Pelvic wall, all points are refering to bony structures. Use of critical organ reference points = maximum rectum dose, bladder dose mean rectal dose. Use of 6,000 rads reference isodose described by height, width, and thickness dimensions. These proposals are the basis of a common language in gynecological brachytherapy [fr

  16. Process control and dosimetry applied to establish a relation between reference dose measurements and actual dose distribution

    Energy Technology Data Exchange (ETDEWEB)

    Ehlerman, D A.E. [Institute of Process Engineering, Federal Research Centre for Nutrition, Karlsruhe (Germany)

    2001-03-01

    The availability of the first commercial dose level indicator prompted attempts to verify radiation absorbed dose to items under quarantine control (e.g. for insect disinfestation) by some indicator attached to these items. Samples of the new commercial dose level indicators were tested for their metrological properties using gamma and electron irradiation. The devices are suitable for the intended purpose and the subjective judgement whether the threshold dose was surpassed is possible in a reliable manner. The subjective judgements are completely backed by the instrumental results. Consequently, a prototype reader was developed; first tests were successful. The value of dose level indicators and the implications of its use for food or quarantine inspection depends on a link between dose measured (indicated) at the position of such indicator and the characteristic parameters of the frequency distribution of dose throughout the product load i.e. a box or a container or a whole batch of multiple units. Therefore, studies into variability and statistical properties of dose distributions obtained under a range of commercial situations were undertaken. Gamma processing at a commercial multipurpose contract irradiator, electron processing and bremsstrahlung applications at a largescale research facility were included; products were apples, potatoes, wheat, maize, pistachio. Studies revealed that still more detailed information on irradiation geometries are needed in order to render meaningful information from dose label indicators. (author)

  17. Process control and dosimetry applied to establish a relation between reference dose measurements and actual dose distribution

    International Nuclear Information System (INIS)

    Ehlerman, D.A.E.

    2001-01-01

    The availability of the first commercial dose level indicator prompted attempts to verify radiation absorbed dose to items under quarantine control (e.g. for insect disinfestation) by some indicator attached to these items. Samples of the new commercial dose level indicators were tested for their metrological properties using gamma and electron irradiation. The devices are suitable for the intended purpose and the subjective judgement whether the threshold dose was surpassed is possible in a reliable manner. The subjective judgements are completely backed by the instrumental results. Consequently, a prototype reader was developed; first tests were successful. The value of dose level indicators and the implications of its use for food or quarantine inspection depends on a link between dose measured (indicated) at the position of such indicator and the characteristic parameters of the frequency distribution of dose throughout the product load i.e. a box or a container or a whole batch of multiple units. Therefore, studies into variability and statistical properties of dose distributions obtained under a range of commercial situations were undertaken. Gamma processing at a commercial multipurpose contract irradiator, electron processing and bremsstrahlung applications at a largescale research facility were included; products were apples, potatoes, wheat, maize, pistachio. Studies revealed that still more detailed information on irradiation geometries are needed in order to render meaningful information from dose label indicators. (author)

  18. Survey of doses and frequency of X-ray examinations on children at the intensive care unit of a large reference pediatric hospital

    International Nuclear Information System (INIS)

    Pedrosa de Azevedo, Ana Cecilia; Osibote, Adelaja Otolorin; Bastos Boechat, Marcia Cristina

    2006-01-01

    Objective: This work aims to evaluate the entrance surface dose (ESD), the body organ dose (BOD) and the effective dose (E) resulting from pediatric radiological procedures with the use of portable X-ray equipments. Materials and methods: The software DoseCal was used to evaluate the doses imparted to patients. The children were classified according to their weight and age groups, and the study included three sectors of the intensive care unit of a large reference pediatric hospital in Rio de Janeiro. Results: A total of 518 radiographs have been performed (424 for chest and 94 for abdomen). The statistical data were compared with previously published results. The BOD is presented for the most exposed organs. Conclusion: The mean value of ESD and E varied widely among neonates. The highest number of radiographs per infant peaked 33 for chest examination in the age group 0-1 year

  19. EPA perspective on radionuclide aerosol sampling

    Energy Technology Data Exchange (ETDEWEB)

    Karhnak, J.M. [Environmental Protection Agency, Washington, DC (United States)

    1995-02-01

    The Environmental Protection Agency (EPA) is concerned with radionuclide aerosol sampling primarily at Department of Energy (DOE) facilities in order to insure compliance with national air emission standards, known as NESHAPs. Sampling procedures are specified in {open_quotes}National Emission Standards for Emissions of Radionuclides other than Radon from Department of Energy Sites{close_quotes} (Subpart H). Subpart H also allows alternate procedures to be used if they meet certain requirements. This paper discusses some of the mission differences between EPA and Doe and how these differences are reflected in decisions that are made. It then describes how the EPA develops standards, considers alternate sampling procedures, and lists suggestions to speed up the review and acceptance process for alternate procedures. The paper concludes with a discussion of the process for delegation of Radionuclide NESHAPs responsibilities to the States, and responsibilities that could be retained by EPA.

  20. EPA Envirofacts API

    Data.gov (United States)

    U.S. Environmental Protection Agency — Envirofacts integrates information from a variety of EPA's environmental databases. Each of these databases contains information about facilities that are required...

  1. Radiobiological modelling of dose-gradient effects in low dose rate, high dose rate and pulsed brachytherapy

    International Nuclear Information System (INIS)

    Armpilia, C; Dale, R G; Sandilos, P; Vlachos, L

    2006-01-01

    This paper presents a generalization of a previously published methodology which quantified the radiobiological consequences of dose-gradient effects in brachytherapy applications. The methodology uses the linear-quadratic (LQ) formulation to identify an equivalent biologically effective dose (BED eq ) which, if applied uniformly to a specified tissue volume, would produce the same net cell survival as that achieved by a given non-uniform brachytherapy application. Multiplying factors (MFs), which enable the equivalent BED for an enclosed volume to be estimated from the BED calculated at the dose reference surface, have been calculated and tabulated for both spherical and cylindrical geometries. The main types of brachytherapy (high dose rate (HDR), low dose rate (LDR) and pulsed (PB)) have been examined for a range of radiobiological parameters/dimensions. Equivalent BEDs are consistently higher than the BEDs calculated at the reference surface by an amount which depends on the treatment prescription (magnitude of the prescribed dose) at the reference point. MFs are closely related to the numerical BED values, irrespective of how the original BED was attained (e.g., via HDR, LDR or PB). Thus, an average MF can be used for a given prescribed BED as it will be largely independent of the assumed radiobiological parameters (radiosensitivity and α/β) and standardized look-up tables may be applicable to all types of brachytherapy treatment. This analysis opens the way to more systematic approaches for correlating physical and biological effects in several types of brachytherapy and for the improved quantitative assessment and ranking of clinical treatments which involve a brachytherapy component

  2. Guidance levels, achievable doses and expectation levels

    International Nuclear Information System (INIS)

    Li, Lianbo; Meng, Bing

    2002-01-01

    The National Radiological Protection Board (NRPB), the International Atomic Energy Agency (IAEA) and the Commission of the European Communities (CEC) published their guidance levels and reference doses for typical X-ray examination and nuclear medicine in their documents in 1993, 1994 and 1996 respectively. From then on, the concept of guidance levels or reference doses have been applied to different examinations in the field of radiology and proved to be effective for reduction of patient doses. But the guidance levels or reference doses are likely to have some shortcomings and can do little to make further reduction of patient dose in the radiology departments where patient dose are already below them. For this reason, the National Radiological Protection Board (NRPB) proposed a concept named achievable doses which are based on the mean dose observed for a selected sample of radiology departments. This paper will review and discuss the concept of guidance levels and achievable doses, and propose a new concept referred to as Expectation Levels that will encourage the radiology departments where patient dose are already below the guidance levels to keep patient dose as low as reasonably achievable. Some examples of the expectation levels based on the data published by a few countries are also illustrated in this paper

  3. Water Quality in Small Community Distribution Systems. A Reference Guide for Operators

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) has developed this reference guide to assist the operators and managers of small- and medium-sized public water systems. This compilation provides a comprehensive picture of the impact of the water distribution system network on dist...

  4. EPA Recovery Mapper

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA Recovery Mapper is an Internet interactive mapping application that allows users to discover information about every American Recovery and Reinvestment Act...

  5. Hispanos en la EPA: Grace Robiou

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  6. Hispanos en la EPA: Fabiola Estrada

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  7. Hispanos en la EPA: Matthew Tejada

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  8. Hispanos en la EPA: Joel Corona

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  9. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 25 avril de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 30 mai, 29 août, 26 septembre, 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  10. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 28 février de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 28 mars, 25 avril, 30 mai, 29 août, 26 septembre, 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  11. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 28 mars de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 25 avril, 30 mai, 29 août, 26 septembre, 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  12. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 30 mai de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 29 août, 26 septembre, 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  13. Safety and Immunogenicity of Pfs25-EPA/Alhydrogel®, a Transmission Blocking Vaccine against Plasmodium falciparum: An Open Label Study in Malaria Naïve Adults.

    Directory of Open Access Journals (Sweden)

    Kawsar R Talaat

    Full Text Available Transmission-blocking vaccines (TBVs that target sexual stage parasite development could be an integral part of measures for malaria elimination. Pfs25 is a leading TBV candidate, and previous studies conducted in animals demonstrated an improvement of its functional immunogenicity after conjugation to EPA, a recombinant, detoxified ExoProtein A from Pseudomonas aeruginosa. In this report, we describe results of an open-label, dose-escalating Phase 1 trial to assess the safety and immunogenicity of Pfs25-EPA conjugates formulated with Alhydrogel®. Thirty malaria-naïve healthy adults received up to four doses of the conjugate vaccine, with 8, 16, or 47 μg of conjugated Pfs25 mass, at 0, 2, 4, and 10 months. Vaccinations were generally well tolerated. The majority of solicited adverse events were mild in severity with pain at the injection site the most common complaint. Anemia was the most common laboratory abnormality, but was considered possibly related to the study in only a minority of cases. No vaccine-related serious adverse events occurred. The peak geometric mean anti-Pfs25 antibody level in the highest dose group was 88 (95% CI 53, 147 μg/mL two weeks after the 4th vaccination, and declined to near baseline one year later. Antibody avidity increased over successive vaccinations. Transmission blocking activity demonstrated in a standard membrane feeding assay (SMFA also increased from the second to the third dose, and correlated with antibody titer and, after the final dose, with antibody avidity. These results support the further evaluation of Pfs25-EPA/Alhydrogel® in a malaria-endemic population.

  14. EPA Linked Open Data: Substance Registry Service

    Data.gov (United States)

    U.S. Environmental Protection Agency — Substance Registry Services (SRS) is the Environmental Protection Agency's (EPA) central system for information about substances that are tracked or regulated by EPA...

  15. Low-level and narm radioactive wastes. Model documentation: accounting model for PRESTO-EPA-POP, PRESTO-EPA-DEEP, and PRESTO-EPA-BRC. Methodology and users manual. Final report

    International Nuclear Information System (INIS)

    Rogers, V.; Hung, C.

    1987-12-01

    The accounting model was used as a utility model for assessing the cumulative health effects to the general population residing in the downstream regional water basin as a result of the disposal of LLW when a unit response analysis method is used. The utility model is specifically designed to assess the cumulative population health effects in conjunction with the PRESTO-EPA-POP, PRESTO-EPA-BRC, or PRESTO-EPA-DEEP model simply for the purpose of reducing the cost of analysis. Therefore, the assessment of the cumulative population health effects may also be conducted with one of the above appropriate models without the aid of this accounting model

  16. EPA User Personas

    Science.gov (United States)

    Learn how EPA's three web user personas (Information Consumer, Information Intermediary, and Information Interpreter) can help you identify appropriate top audiences and top tasks for a topic or web area.

  17. EPA Nanorelease Dataset

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPA Nanorelease Dataset. This dataset is associated with the following publication: Wohlleben, W., C. Kingston, J. Carter, E. Sahle-Demessie, S. Vazquez-Campos, B....

  18. Perfiles de hispanos en la EPA

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente de todos.

  19. ANALYSIS OF RESPIRATORY DEPOSITION OF INHALED AMBIENT AEROSOLS FOR DIFFERENT DOSE METRICS

    Science.gov (United States)

    ANALYSIS OF RESPIRATORY DEPOSITION OF INHALED AMBIENT AEROSOLS FOR DIFFERENT DOSE METRICS.Chong S. Kim, SC. Hu**, PA Jaques*, US EPA, National Health and Environmental Effects Research Laboratory, Research Triangle Park, NC 27711; **IIT Research Institute, Chicago, IL; *South...

  20. EPA's role in uranium mining and milling

    International Nuclear Information System (INIS)

    Smith, P.B.

    1980-01-01

    EPA's role and actions in regulating uranium mining and milling are reviewed and updated. Special emphasis is given to EPA's current activities under the Uranium Mill Tailings Radiation Control Act of 1978

  1. Local patient dose diagnostic reference levels in pediatric interventional cardiology in Chile using age bands and patient weight values

    Energy Technology Data Exchange (ETDEWEB)

    Ubeda, Carlos, E-mail: cubeda@uta.cl [Medical Technology Department, Radiological Sciences Center, Health Sciences Faculty, Tarapaca University, Arica 1000000 (Chile); Miranda, Patricia [Hemodynamic Department, Cardiovascular Service, Luis Calvo Mackenna Hospital, Santiago 7500539 (Chile); Vano, Eliseo [Radiology Department, Faculty of Medicine, Complutense University and IdIS, San Carlos Hospital, Madrid 28040 (Spain)

    2015-02-15

    Purpose: To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. Methods: Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-area product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. Results: Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for <1 yr; 213 for 1 to <5 yr; 82 for 5 to <10 yr; and 102 for 10 to <16 yr. The third quartile values obtained for DAP by diagnostic and therapeutic procedures and age range were 1.17 and 1.11 Gy cm{sup 2} for <1 yr; 1.74 and 1.90 Gy cm{sup 2} for 1 to <5 yr; 2.83 and 3.22 Gy cm{sup 2} for 5 to <10 yr; and 7.34 and 8.68 Gy cm{sup 2} for 10 to <16 yr, respectively. The third quartile value obtained for the DAP/body weight ratio for the full sample of procedures was 0.17 (Gy cm{sup 2}/kg) for diagnostic and therapeutic procedures. Conclusions: The data presented in this paper are an initial attempt at establishing local DRLs in pediatric interventional cardiology, from a large sample of procedures for the standard age bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there

  2. Local patient dose diagnostic reference levels in pediatric interventional cardiology in Chile using age bands and patient weight values

    International Nuclear Information System (INIS)

    Ubeda, Carlos; Miranda, Patricia; Vano, Eliseo

    2015-01-01

    Purpose: To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. Methods: Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-area product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. Results: Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for <1 yr; 213 for 1 to <5 yr; 82 for 5 to <10 yr; and 102 for 10 to <16 yr. The third quartile values obtained for DAP by diagnostic and therapeutic procedures and age range were 1.17 and 1.11 Gy cm 2 for <1 yr; 1.74 and 1.90 Gy cm 2 for 1 to <5 yr; 2.83 and 3.22 Gy cm 2 for 5 to <10 yr; and 7.34 and 8.68 Gy cm 2 for 10 to <16 yr, respectively. The third quartile value obtained for the DAP/body weight ratio for the full sample of procedures was 0.17 (Gy cm 2 /kg) for diagnostic and therapeutic procedures. Conclusions: The data presented in this paper are an initial attempt at establishing local DRLs in pediatric interventional cardiology, from a large sample of procedures for the standard age bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there may be large differences

  3. Pollution prevention initiatives at US EPA: 'Green Lights'

    International Nuclear Information System (INIS)

    Lawson, J.; Kwartin, R.

    1991-01-01

    US EPA is initiating a pollution prevention approach to supplement its historic command-control, regulatory approach to environmental protection. EPA believes polllution prevention, where applicable and possible, represents a quicker, less expensive and even profitable strategy for environmental protection. Most clearly, energy-efficiency provides an opportunity to prevent significant amounts of pollution related to the inefficeint generation and use of electricity. EPA's first energy productivity and pollution prevention program is Green Lights. Beyond its own merits, Green Lights will also provide important experience to EPA as it develops its Green Machines program to accelerate the market for efficient appliances and equipment

  4. Privacy Act System of Records: EPA Telecommunications Detail Records, EPA-32

    Science.gov (United States)

    Learn more about the EPA Telecommunications Detail Records System, including who is covered in the system, the purpose of data collection, routine uses for the system's records, and other security procedures.

  5. 40 CFR 73.52 - EPA recordation.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false EPA recordation. 73.52 Section 73.52... ALLOWANCE SYSTEM Allowance Transfers § 73.52 EPA recordation. (a) General recordation. Except as provided in...) following receipt of an allowance transfer request pursuant to § 73.50, by moving each allowance from the...

  6. Effects of aspirin in combination with EPA and DHA on HDL-C cholesterol and ApoA1 exchange in individuals with type 2 diabetes mellitus.

    Science.gov (United States)

    Block, Robert C; Holub, Ashley; Abdolahi, Amir; Tu, Xin M; Mousa, Shaker A; Oda, Michael N

    2017-11-01

    Low-dose aspirin is an effective drug for the prevention of cardiovascular disease (CVD) events but individuals with diabetes mellitus can be subject to 'aspirin resistance'. Thus, aspirin's effect in these individuals is controversial. Higher blood levels of seafood-derived omega-3 polyunsaturated fatty acids (ω3) eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) also have beneficial effects in reducing risk of CVD events but few studies have examined the interaction of plasma EPA and DHA with aspirin ingestion. Our study examined the combinatory effects of EPA, DHA, and aspirin ingestion on HDL-cholesterol (HDL-C) and apoA-I exchange (shown to be associated with CVD event risk). 30 adults with Type 2 diabetes mellitus ingested aspirin (81mg/day) for 7 consecutive days, EPA+DHA (2.6g/day) for 28 days, then both for 7 days. Plasma was collected at baseline and at 5 subsequent visits including 4h after each aspirin ingestion. Mixed model methods were used to determine HDL-C-concentrations and apoA-I exchange compared to the baseline visit values. LOWESS curves were used for non-linear analyses of outcomes to help discern change patterns, which was followed by piecewise linear functions for formal testing of curvilinear relationships. Significant changes (p aspirin-only ingestion, apoA-I exchange was significantly modified by increasing levels of DHA concentration, with increased apoA-I exchange observed up until log(DHA) of 4.6 and decreased exchange thereafter (p = 0.03). These LOWESS curve effects were not observed for EPA or HDL-C (p > 0.05). Aspirin's effects on apoA-I exchange were the greatest when EPA or DHA concentrations were moderate compared to high or low. Comparison of EPA, DHA, and EPA+DHA LOWESS curves, demonstrated that the majority of the effect is due to DHA. Our results strongly suggest that plasma concentrations of EPA and DHA influence aspirin effects on lipid mediators of CVD event risk where their concentrations are most beneficial

  7. Approaches to cancer assessment in EPA's Integrated Risk Information System.

    Science.gov (United States)

    Gehlhaus, Martin W; Gift, Jeffrey S; Hogan, Karen A; Kopylev, Leonid; Schlosser, Paul M; Kadry, Abdel-Razak

    2011-07-15

    The U.S. Environmental Protection Agency's (EPA) Integrated Risk Information System (IRIS) Program develops assessments of health effects that may result from chronic exposure to chemicals in the environment. The IRIS database contains more than 540 assessments. When supported by available data, IRIS assessments provide quantitative analyses of carcinogenic effects. Since publication of EPA's 2005 Guidelines for Carcinogen Risk Assessment, IRIS cancer assessments have implemented new approaches recommended in these guidelines and expanded the use of complex scientific methods to perform quantitative dose-response assessments. Two case studies of the application of the mode of action framework from the 2005 Cancer Guidelines are presented in this paper. The first is a case study of 1,2,3-trichloropropane, as an example of a chemical with a mutagenic mode of carcinogenic action thus warranting the application of age-dependent adjustment factors for early-life exposure; the second is a case study of ethylene glycol monobutyl ether, as an example of a chemical with a carcinogenic action consistent with a nonlinear extrapolation approach. The use of physiologically based pharmacokinetic (PBPK) modeling to quantify interindividual variability and account for human parameter uncertainty as part of a quantitative cancer assessment is illustrated using a case study involving probabilistic PBPK modeling for dichloromethane. We also discuss statistical issues in assessing trends and model fit for tumor dose-response data, analysis of the combined risk from multiple types of tumors, and application of life-table methods for using human data to derive cancer risk estimates. These issues reflect the complexity and challenges faced in assessing the carcinogenic risks from exposure to environmental chemicals, and provide a view of the current trends in IRIS carcinogenicity risk assessment. Copyright © 2011. Published by Elsevier Inc.

  8. Approaches to cancer assessment in EPA's Integrated Risk Information System

    International Nuclear Information System (INIS)

    Gehlhaus, Martin W.; Gift, Jeffrey S.; Hogan, Karen A.; Kopylev, Leonid; Schlosser, Paul M.; Kadry, Abdel-Razak

    2011-01-01

    The U.S. Environmental Protection Agency's (EPA) Integrated Risk Information System (IRIS) Program develops assessments of health effects that may result from chronic exposure to chemicals in the environment. The IRIS database contains more than 540 assessments. When supported by available data, IRIS assessments provide quantitative analyses of carcinogenic effects. Since publication of EPA's 2005 Guidelines for Carcinogen Risk Assessment, IRIS cancer assessments have implemented new approaches recommended in these guidelines and expanded the use of complex scientific methods to perform quantitative dose-response assessments. Two case studies of the application of the mode of action framework from the 2005 Cancer Guidelines are presented in this paper. The first is a case study of 1,2,3-trichloropropane, as an example of a chemical with a mutagenic mode of carcinogenic action thus warranting the application of age-dependent adjustment factors for early-life exposure; the second is a case study of ethylene glycol monobutyl ether, as an example of a chemical with a carcinogenic action consistent with a nonlinear extrapolation approach. The use of physiologically based pharmacokinetic (PBPK) modeling to quantify interindividual variability and account for human parameter uncertainty as part of a quantitative cancer assessment is illustrated using a case study involving probabilistic PBPK modeling for dichloromethane. We also discuss statistical issues in assessing trends and model fit for tumor dose-response data, analysis of the combined risk from multiple types of tumors, and application of life-table methods for using human data to derive cancer risk estimates. These issues reflect the complexity and challenges faced in assessing the carcinogenic risks from exposure to environmental chemicals, and provide a view of the current trends in IRIS carcinogenicity risk assessment.

  9. EPA Region 1 Sole Source Aquifers

    Science.gov (United States)

    This coverage contains boundaries of EPA-approved sole source aquifers. Sole source aquifers are defined as an aquifer designated as the sole or principal source of drinking water for a given aquifer service area; that is, an aquifer which is needed to supply 50% or more of the drinking water for the area and for which there are no reasonable alternative sources should the aquifer become contaminated.The aquifers were defined by a EPA hydrogeologist. Aquifer boundaries were then drafted by EPA onto 1:24000 USGS quadrangles. For the coastal sole source aquifers the shoreline as it appeared on the quadrangle was used as a boundary. Delineated boundaries were then digitized into ARC/INFO.

  10. 77 FR 29275 - Oklahoma: Incorporation by Reference of State Hazardous Waste Management Program

    Science.gov (United States)

    2012-05-17

    ...: Incorporation by Reference of State Hazardous Waste Management Program AGENCY: Environmental Protection Agency... ``Approved State Hazardous Waste Management Programs'', Oklahoma's authorized hazardous waste program. The... State regulations that are authorized and that the EPA will enforce under the Solid Waste Disposal Act...

  11. 77 FR 46994 - Oklahoma: Incorporation by Reference of State Hazardous Waste Management Program

    Science.gov (United States)

    2012-08-07

    ...: Incorporation by Reference of State Hazardous Waste Management Program AGENCY: Environmental Protection Agency... ``Approved State Hazardous Waste Management Programs'', Oklahoma's authorized hazardous waste program. The... State regulations that are authorized and that the EPA will enforce under the Solid Waste Disposal Act...

  12. 75 FR 36609 - Oklahoma: Incorporation by Reference of State Hazardous Waste Management Program

    Science.gov (United States)

    2010-06-28

    ...: Incorporation by Reference of State Hazardous Waste Management Program AGENCY: Environmental Protection Agency... ``Approved State Hazardous Waste Management Programs'', Oklahoma's authorized hazardous waste program. The... State regulations that are authorized and that the EPA will enforce under the Solid Waste Disposal Act...

  13. Meet EPA Engineer Shawn Ryan, Ph.D.

    Science.gov (United States)

    Shawn Ryan, Ph.D. is a chemical engineer at EPA's National Homeland Security Research Center. He has worked at EPA for 12 years, nine of which have been devoted to leading research to support decontamination and consequence management.

  14. Conversion of ICRP male reference phantom to polygon-surface phantom

    International Nuclear Information System (INIS)

    Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi

    2013-01-01

    The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (<2 man-months), we were able to construct the polygon-surface phantom with the organ masses perfectly matching the ICRP reference values. The analysis of the calculated dose values also implies that the dose values are indeed not very sensitive to the detailed morphology of the organ models in the phantom

  15. A Web-Based System for Bayesian Benchmark Dose Estimation.

    Science.gov (United States)

    Shao, Kan; Shapiro, Andrew J

    2018-01-11

    Benchmark dose (BMD) modeling is an important step in human health risk assessment and is used as the default approach to identify the point of departure for risk assessment. A probabilistic framework for dose-response assessment has been proposed and advocated by various institutions and organizations; therefore, a reliable tool is needed to provide distributional estimates for BMD and other important quantities in dose-response assessment. We developed an online system for Bayesian BMD (BBMD) estimation and compared results from this software with U.S. Environmental Protection Agency's (EPA's) Benchmark Dose Software (BMDS). The system is built on a Bayesian framework featuring the application of Markov chain Monte Carlo (MCMC) sampling for model parameter estimation and BMD calculation, which makes the BBMD system fundamentally different from the currently prevailing BMD software packages. In addition to estimating the traditional BMDs for dichotomous and continuous data, the developed system is also capable of computing model-averaged BMD estimates. A total of 518 dichotomous and 108 continuous data sets extracted from the U.S. EPA's Integrated Risk Information System (IRIS) database (and similar databases) were used as testing data to compare the estimates from the BBMD and BMDS programs. The results suggest that the BBMD system may outperform the BMDS program in a number of aspects, including fewer failed BMD and BMDL calculations and estimates. The BBMD system is a useful alternative tool for estimating BMD with additional functionalities for BMD analysis based on most recent research. Most importantly, the BBMD has the potential to incorporate prior information to make dose-response modeling more reliable and can provide distributional estimates for important quantities in dose-response assessment, which greatly facilitates the current trend for probabilistic risk assessment. https://doi.org/10.1289/EHP1289.

  16. Meet EPA Ecologist Paul Mayer, Ph.D.

    Science.gov (United States)

    EPA ecologist Paul Mayer, Ph.D. works in EPA's Groundwater and Ecosystem Restoration division where he studies riparian zones (the area along rivers and streams where the habitats are influenced by both the land and water) and stream restoration

  17. Doses from radiation exposure

    CERN Document Server

    Menzel, H G

    2012-01-01

    Practical implementation of the International Commission on Radiological Protection's (ICRP) system of protection requires the availability of appropriate methods and data. The work of Committee 2 is concerned with the development of reference data and methods for the assessment of internal and external radiation exposure of workers and members of the public. This involves the development of reference biokinetic and dosimetric models, reference anatomical models of the human body, and reference anatomical and physiological data. Following ICRP's 2007 Recommendations, Committee 2 has focused on the provision of new reference dose coefficients for external and internal exposure. As well as specifying changes to the radiation and tissue weighting factors used in the calculation of protection quantities, the 2007 Recommendations introduced the use of reference anatomical phantoms based on medical imaging data, requiring explicit sex averaging of male and female organ-equivalent doses in the calculation of effecti...

  18. Dose volume assessment of high dose rate 192IR endobronchial implants

    International Nuclear Information System (INIS)

    Cheng, B. Saw; Korb, Leroy J.; Pawlicki, Todd; Wu, Andrew

    1996-01-01

    Purpose: To study the dose distributions of high dose rate (HDR) endobronchial implants using the dose nonuniformity ratio (DNR) and three volumetric irradiation indices. Methods and Materials: Multiple implants were configured by allowing a single HDR 192 Ir source to step through a length of 6 cm along an endobronchial catheter. Dwell times were computed to deliver a dose of 5 Gy to points 1 cm away from the catheter axis. Five sets of source configurations, each with different dwell position spacings from 0.5 to 3.0 cm, were evaluated. Three-dimensional (3D) dose distributions were then generated for each source configuration. Differential and cumulative dose-volume curves were generated to quantify the degree of target volume coverage, dose nonuniformity within the target volume, and irradiation of tissues outside the target volume. Evaluation of the implants were made using the DNR and three volumetric irradiation indices. Results: The observed isodose distributions were not able to satisfy all the dose constraints. The ability to optimally satisfy the dose constraints depended on the choice of dwell position spacing and the specification of the dose constraint points. The DNR and irradiation indices suggest that small dwell position spacing does not result in a more homogeneous dose distribution for the implant. This study supports the existence of a relationship between the dwell position spacing and the distance from the catheter axis to the reference dose or dose constraint points. Better dose homogeneity for an implant can be obtained if the spacing of the dwell positions are about twice the distance from the catheter axis to the reference dose or dose constraint points

  19. US EPA Regional Masks Web Service, US, 2015, US EPA, SEGS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web service contains the following map layers: masks and labels for EPA regions 1 through 10. Mask layers are drawn at all scales. Label layers draw at scales...

  20. Proposed Changes to EPA's Transuranic Waste Characterization Approval Process

    International Nuclear Information System (INIS)

    Joglekar, R.D.; Feltcorn, E.M.; Ortiz, A.M.

    2003-01-01

    This paper describes the changes to the waste characterization (WC) approval process proposed in August 2002 by the U.S. Environmental Protection Agency (EPA or the Agency or we). EPA regulates the disposal of transuranic (TRU) waste at the Waste Isolation Pilot Plant (WIPP) repository in Carlsbad, New Mexico. EPA regulations require that waste generator/storage sites seek EPA approval of WC processes used to characterize TRU waste destined for disposal at WIPP. The regulations also require that EPA verify, through site inspections, characterization of each waste stream or group of waste streams proposed for disposal at the WIPP. As part of verification, the Agency inspects equipment, procedures, and interviews personnel to determine if the processes used by a site can adequately characterize the waste in order to meet the waste acceptance criteria for WIPP. The paper discusses EPA's mandate, current regulations, inspection experience, and proposed changes. We expect that th e proposed changes will provide equivalent or improved oversight. Also, they would give EPA greater flexibility in scheduling and conducting inspections, and should clarify the regulatory process of inspections for both Department of Energy (DOE) and the public

  1. A methodology for estimating potential doses and risks from recycling U.S. Department of Energy radioactive scrap metals

    International Nuclear Information System (INIS)

    MacKinney, J.A.

    1995-01-01

    The U.S. Environmental Protection Agency (EPA) is considering writing regulations for the controlled use of materials originating from radioactively contaminated zones which may be recyclable. These materials include metals, such as steel (carbon and stainless), nickel, copper, aluminum and lead, from the decommissioning of federal, and non-federal facilities. To develop criteria for the release of such materials, a risk analysis of all potential exposure pathways should be conducted. These pathways include direct exposure to the recycled material by the public and workers, both individual and collective, as well as numerous other potential exposure pathways in the life of the material. EPA has developed a risk assessment methodology for estimating doses and risks associated with recycling radioactive scrap metals. This methodology was applied to metal belonging to the U.S. Department of Energy. This paper will discuss the draft EPA risk assessment methodology as a tool for estimating doses and risks from recycling. (author)

  2. Towards the production of EPA: a developing country perspective

    CSIR Research Space (South Africa)

    Maharajh, Dheepak M

    2015-03-01

    Full Text Available are focussed towards increased production of high purity EPA. This provides a window of opportunity for a supply of competing products that are rich in algal EPA. Recently the CSIR developed a technology for the production of EPA by an indigenous algal isolate...

  3. Direct dose mapping versus energy/mass transfer mapping for 4D dose accumulation: fundamental differences and dosimetric consequences.

    Science.gov (United States)

    Li, Haisen S; Zhong, Hualiang; Kim, Jinkoo; Glide-Hurst, Carri; Gulam, Misbah; Nurushev, Teamour S; Chetty, Indrin J

    2014-01-06

    The direct dose mapping (DDM) and energy/mass transfer (EMT) mapping are two essential algorithms for accumulating the dose from different anatomic phases to the reference phase when there is organ motion or tumor/tissue deformation during the delivery of radiation therapy. DDM is based on interpolation of the dose values from one dose grid to another and thus lacks rigor in defining the dose when there are multiple dose values mapped to one dose voxel in the reference phase due to tissue/tumor deformation. On the other hand, EMT counts the total energy and mass transferred to each voxel in the reference phase and calculates the dose by dividing the energy by mass. Therefore it is based on fundamentally sound physics principles. In this study, we implemented the two algorithms and integrated them within the Eclipse treatment planning system. We then compared the clinical dosimetric difference between the two algorithms for ten lung cancer patients receiving stereotactic radiosurgery treatment, by accumulating the delivered dose to the end-of-exhale (EE) phase. Specifically, the respiratory period was divided into ten phases and the dose to each phase was calculated and mapped to the EE phase and then accumulated. The displacement vector field generated by Demons-based registration of the source and reference images was used to transfer the dose and energy. The DDM and EMT algorithms produced noticeably different cumulative dose in the regions with sharp mass density variations and/or high dose gradients. For the planning target volume (PTV) and internal target volume (ITV) minimum dose, the difference was up to 11% and 4% respectively. This suggests that DDM might not be adequate for obtaining an accurate dose distribution of the cumulative plan, instead, EMT should be considered.

  4. Dose reference levels in Spanish intraoral dental radiology: stabilisation of the incorporation of digital systems in dental clinical practices

    International Nuclear Information System (INIS)

    Alcaraz, M.; Velasco, F.; Olivares, A.; Velasco, E.; Canteras, M.

    2016-01-01

    A total of 34 044 official quality assurance reports in dental radiodiagnostic surgery from 16 regions of Spain, compiled from 2002 to 2014, were studied in order to determine the progress of diagnostic reference levels (DRLs) for obtaining diagnostic images under normal conditions for clinical practice in Spanish dental clinics. A DRL of 2.8 mGy was set in 2014, which represents a 41.7 % decrease compared with that of 2002 (4.8 mGy). Over the same time period, the mean dose fell by 55.2 %. However, over the last 3 y, the stabilisation of the mean dose administered to patients has been observed with only a 6.7 % reduction in DRLs, which corresponds to the stabilisation of dental radiodiagnostic surgery on replacing the use of radiographic film with digital imaging systems. (authors)

  5. Reference computations of public dose and cancer risk from airborne releases of plutonium. Nuclear safety technical report

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, V.L.

    1993-12-23

    This report presents results of computations of doses and the associated health risks of postulated accidental atmospheric releases from the Rocky Flats Plant (RFP) of one gram of weapons-grade plutonium in a form that is respirable. These computations are intended to be reference computations that can be used to evaluate a variety of accident scenarios by scaling the dose and health risk results presented here according to the amount of plutonium postulated to be released, instead of repeating the computations for each scenario. The MACCS2 code has been used as the basis of these computations. The basis and capabilities of MACCS2 are summarized, the parameters used in the evaluations are discussed, and results are presented for the doses and health risks to the public, both the Maximum Offsite Individual (a maximally exposed individual at or beyond the plant boundaries) and the population within 50 miles of RFP. A number of different weather scenarios are evaluated, including constant weather conditions and observed weather for 1990, 1991, and 1992. The isotopic mix of weapons-grade plutonium will change as it ages, the {sup 241}Pu decaying into {sup 241}Am. The {sup 241}Am reaches a peak concentration after about 72 years. The doses to the bone surface, liver, and whole body will increase slightly but the dose to the lungs will decrease slightly. The overall cancer risk will show almost no change over this period. This change in cancer risk is much smaller than the year-to-year variations in cancer risk due to weather. Finally, x/Q values are also presented for other applications, such as for hazardous chemical releases. These include the x/Q values for the MOI, for a collocated worker at 100 meters downwind of an accident site, and the x/Q value integrated over the population out to 50 miles.

  6. RISK PERCEPTION AND DIFFUSION OF MERCURY RISK INFORMATION

    Science.gov (United States)

    The most recent NHANES data reveals that approximately 8% of American women have blood Mercury levels exceeding the EPA reference dose (a dose below which symptoms would be unlikely). The children of these women are at risk of neurological deficits (lower IQ scores) primarily bec...

  7. PERCEPTION OF MERCURY RISK INFORMATION

    Science.gov (United States)

    Approximately 8% of American women have blood Mercury levels exceeding the EPA reference dose (a dose below which symptoms would be unlikely). The children of these women are at risk of neurological deficits (lower IQ scores) primarily because of the mother's consumption of conta...

  8. DIFFUSION AND PERCEPTION OF MERCURY RISK INFORMATION

    Science.gov (United States)

    Approximately 8% of American women have blood Mercury levels exceeding the EPA reference dose (a dose below which symptoms would be unlikely). The children of these women are at risk of neurological deficits (lower IQ scores) primarily because of the mother’s consumption of...

  9. 75 FR 45583 - New York: Incorporation by Reference of State Hazardous Waste Management Program

    Science.gov (United States)

    2010-08-03

    ...: Incorporation by Reference of State Hazardous Waste Management Program AGENCY: Environmental Protection Agency... authorized hazardous waste program which is set forth in the regulations entitled ``Approved State Hazardous Waste Management Programs'', New York's authorized hazardous waste program. EPA will incorporate by...

  10. 77 FR 3224 - New Mexico: Incorporation by Reference of State Hazardous Waste Management Program

    Science.gov (United States)

    2012-01-23

    ... Mexico: Incorporation by Reference of State Hazardous Waste Management Program AGENCY: Environmental... entitled ``Approved State Hazardous Waste Management Programs,'' New Mexico's authorized hazardous waste... of the State regulations that are authorized and that the EPA will enforce under the Solid Waste...

  11. ANALYSIS OF RESPIRATORY DESPOSITION DOSE OF INHALED AMBIENT AEROSOLS FOR DIFFERENT SIZE FRACTIONS

    Science.gov (United States)

    ANALYSIS OF RESPIRATORY DEPOSITION DOSE OF INHALED AMBIENT AEROSOLS FOR DIFFERENT SIZE FRACTIONS. Chong S. Kim, SC. Hu**, PA Jaques*, US EPA, National Health and Environmental Effects Research Laboratory, Research Triangle Park, NC 27711; **IIT Research Institute, Chicago, IL; *S...

  12. EPA (Environmental Protection Agency) Indoor-Air Quality Implementation Plan. A report to Congress under Title IV of the Superfund Amendments and Reauthorization Act of 1986: radon gas and indoor air-quality research. Final report

    International Nuclear Information System (INIS)

    1987-06-01

    The EPA Indoor Air Quality Implementation Plan provides information on the direction of EPA's indoor air program, including the Agency's policy on indoor air and priorities for research and information dissemination over the next two years. EPA submitted the report to Congress on July 2, 1987 as required by the Superfund Amendments and Reauthorization Act of 1986. There are five appendices to the report: Appendix A--Preliminary Indoor Air Pollution Information Assessment; Appendix B--FY 87 Indoor Air Research Program; Appendix C--EPA Radon Program; Appendix D--Indoor Air Resource History (Published with Appendix C); Appendix E--Indoor Air Reference Data Base

  13. Development of beta reference radiations

    International Nuclear Information System (INIS)

    Wan Zhaoyong; Cai Shanyu; Li Yanbo; Yin Wei; Feng Jiamin; Sun Yuhua; Li Yongqiang

    1997-09-01

    A system of beta reference radiation has been developed, that is composed of 740 MBq 147 Pm beta source, 74 MBq and 740 MBq 90 Sr + 90 Y β sources, compensation filters, a source handling tool, a source jig, spacing bars, a shutter, a control unit and a beta dose meter calibration stand. For 740 MBq 147 Pm and 74 MBq 90 Sr + 90 Y beta reference radiations with compensation filters and 740 MBq 90 Sr + 90 Y beta reference radiation without compensation filter, at 20 cm, 30 cm and 30 cm distance separately; the residual energy of maximum is 0.14 MeV, 1.98 MeV and 2.18 MeV separately; the absorbed dose to tissue D (0.07) is 1.547 mGy/h (1996-05-20), 5.037 mGy/h (1996-05-10) and 93.57 mGy/h (1996-05-15) separately; the total uncertainty is 3.0%, 1.7% and 1.7% separately. For the first and the second beta reference radiation, the dose rate variability in the area of 18 cm diameter in the plane perpendicular to the beta-ray beam axis is within +-6% and +-3% separately. (3 refs., 2 tabs., 8 figs.)

  14. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1997-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume -- Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) -- Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  15. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1996-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume --Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) --Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  16. How accurately can the peak skin dose in fluoroscopy be determined using indirect dose metrics?

    International Nuclear Information System (INIS)

    Jones, A. Kyle; Ensor, Joe E.; Pasciak, Alexander S.

    2014-01-01

    Purpose: Skin dosimetry is important for fluoroscopically-guided interventions, as peak skin doses (PSD) that result in skin reactions can be reached during these procedures. There is no consensus as to whether or not indirect skin dosimetry is sufficiently accurate for fluoroscopically-guided interventions. However, measuring PSD with film is difficult and the decision to do so must be madea priori. The purpose of this study was to assess the accuracy of different types of indirect dose estimates and to determine if PSD can be calculated within ±50% using indirect dose metrics for embolization procedures. Methods: PSD were measured directly using radiochromic film for 41 consecutive embolization procedures at two sites. Indirect dose metrics from the procedures were collected, including reference air kerma. Four different estimates of PSD were calculated from the indirect dose metrics and compared along with reference air kerma to the measured PSD for each case. The four indirect estimates included a standard calculation method, the use of detailed information from the radiation dose structured report, and two simplified calculation methods based on the standard method. Indirect dosimetry results were compared with direct measurements, including an analysis of uncertainty associated with film dosimetry. Factors affecting the accuracy of the different indirect estimates were examined. Results: When using the standard calculation method, calculated PSD were within ±35% for all 41 procedures studied. Calculated PSD were within ±50% for a simplified method using a single source-to-patient distance for all calculations. Reference air kerma was within ±50% for all but one procedure. Cases for which reference air kerma or calculated PSD exhibited large (±35%) differences from the measured PSD were analyzed, and two main causative factors were identified: unusually small or large source-to-patient distances and large contributions to reference air kerma from cone

  17. EPA Facility Registry Service (FRS): Wastewater Treatment Plants

    Data.gov (United States)

    U.S. Environmental Protection Agency — This GIS dataset contains data on wastewater treatment plants, based on EPA's Facility Registry Service (FRS), EPA's Integrated Compliance Information System (ICIS)...

  18. EPA SCIENCE FORUM - EPA'S TOXICOGENOMICS PARTNERSHIPS ACROSS GOVERNMENT, ACADEMIA AND INDUSTRY

    Science.gov (United States)

    Over the past decade genomics, proteomics and metabonomics technologies have transformed the science of toxicology, and concurrent advances in computing and informatics have provided management and analysis solutions for this onslaught of toxicogenomic data. EPA has been actively...

  19. 77 FR 26751 - Integrated Risk Information System (IRIS); Announcement of 2012 Program

    Science.gov (United States)

    2012-05-07

    ... supported by available data, IRIS provides oral reference doses (RfDs) and inhalation reference... assessment. Similarly, the oral and inhalation assessments for chromium VI will be combined and proceed... review was conducted by an independent Pathology Working Group (PWG), jointly sponsored by EPA and the...

  20. EPA Scientific Knowledge Management Assessment and Needs

    Science.gov (United States)

    A series of activities have been conducted by a core group of EPA scientists from across the Agency. The activities were initiated in 2012 and the focus was to increase the reuse and interoperability of science software at EPA. The need for increased reuse and interoperability ...

  1. Hispanos en la EPA: Evelyn Rivera-Ocasio

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  2. Hispanos en la EPA: Nadtya Y. Hong

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  3. Privacy Act System of Records: EPA Personnel Emergency Contact Files, EPA-44

    Science.gov (United States)

    Learn about the EPA Personnel Emergency Contact Files System, including including who is covered in the system, the purpose of data collection, routine uses for the system's records, and other security procedure.

  4. 77 FR 36533 - Notice of Availability of the Benchmark Dose Technical Guidance

    Science.gov (United States)

    2012-06-19

    ... environment, the EPA routinely conducts risk assessments on chemical agents that may be toxic to humans. A key component of the risk assessment process involves evaluating the dose-response relationship between exposure... BMD methodology for human health risk assessments. The document discusses computation of BMD values...

  5. Dosimetric verification for radiotherapy quality audit under reference and non-reference conditions in Jiangsu province

    International Nuclear Information System (INIS)

    Wang Jin; Yu Ningle; Yang Chunyong; Du Xiang; Chen Wei; Luo Suming

    2014-01-01

    Objective: To verify the methodology for auditing dosimetric parameters in reference and non-reference conditions with thermoluminescent dosimeters (TLDs). Methods: Under reference and non-reference conditions, the established TLD methods were used to observe the absorbed dose variations with depth, SSD, field size and 45 wedges for 10 photon beams at 5 hospitals. Dosimetric parameters, including doses at D_m_a_x points in axis, on 5 electron beams of 9 MeV were measured. The measurement results were compared between the TLDs and plane parallel ionization chambers. Results: For 6 MV photon beams, the relative deviation of between finger ionization chamber method and TLD chips was in the range of -1.7% to 5.4% under on-axis non-reference conditions, and -6.3% to -0.6% under off-axis non-reference conditions, respectively, all within the range of ≤ ±7% as required by the IAEA. The relative deviation between plane parallel chamber and TLD method was -2.3% to 3.7%, within ±5% as required by the IAEA. Conclusions: It is convenient and feasible to use TLD method for quality audits of dosimetric parameters in radiotherapy. (authors)

  6. EPA's Final Financial Assistance Conflict of Interest Policy

    Science.gov (United States)

    EPA has established the following revised interim policy governing disclosure of actual and potential conflicts of interest (COI Policy) by applicants for, and recipients of, federal financial assistance awards from EPA.

  7. The ampakine, Org 26576, bolsters early spatial reference learning and retrieval in the Morris water maze: a subchronic, dose-ranging study in rats.

    Science.gov (United States)

    Hamlyn, Eugene; Brand, Linda; Shahid, Mohammed; Harvey, Brian H

    2009-10-01

    Ampakines have shown beneficial effects on cognition in selected animal models of learning. However, their ability to modify long-term spatial memory tasks has not been studied yet. This would lend credence to their possible value in treating disorders of cognition. We evaluated the actions of subchronic Org 26576 administration on spatial reference memory performance in the 5-day Morris water maze task in male Sprague-Dawley rats, at doses of 1, 3 and 10 mg/kg twice daily through intraperitoneal injection over 12 days. Org 26576 exerted a dose and time-dependent effect on spatial learning, with dosages of 3 and 10 mg/kg significantly enhancing acquisition on day 1. Globally, escape latency decreased significantly as the training days progressed in the saline and Org 26576-treated groups, indicating that significant and equal learning had taken place over the learning period. However, at the end of the learning period, all doses of Org 26576 significantly improved spatial memory storage/retrieval without confounding effects in the cued version of the task. Org 26576 offers early phase spatial memory benefits in rats, but particularly enhances search accuracy during reference memory retrieval. These results support its possible utility in treating disorders characterized by deficits in cognitive performance.

  8. Radiolysis of n-dodecane and its physical property change based on the dose in one pass through a reference high active (HA) column

    International Nuclear Information System (INIS)

    Ikeda, Hidematsu; Suzuki, Atsuyuki

    1998-01-01

    The radiolysis of n-dodecane which is used both as diluent and as scrub solution and its physical property change were studied by irradiation from a 60 Co γ-source under the relative condition of the HA column in Purex process. First, the radiation exposure of organic phase in one pass through the HA columns were calculated by using the reference HA columns. Then, the radiolysis of the commercial n-dodecane without purification was investigated under the several dose conditions based on the absorption in one pass through the reference HA columns. A large variety of additional n-alkane degradation products was observed and they were increased with dose. The G-value in lower exposure was a high yield, and the absolute G-value decreased with increasing radiation exposure to 1.01 W·h/l. Several expected inferable species from previous literature and three schemes for both principal radiolysis products and reaction of n-dodecane were suggested. These chemical products were probably formed in open system with gamma rays. The physical property change was also performed, and the effect of decomposition products on its change was small but not ignored. The annular with nozzle plates column diminished the absorbed dose in comparison with the other combination columns. (author)

  9. Cuban typical doses for 99mTc-DMSA renal gammagraphy studies: a methodology for the establishment of reference levels

    International Nuclear Information System (INIS)

    Diaz Barreto, M.; Varela Corona, C.; Lopez Bejerano, G.M.; Perea Diaz, M.; Paz Viera, J.E.

    2008-01-01

    Since a handful of years ago, international rules on Radiological Protection include the principle of optimization of given dose to patients, if this procedure doesn't lessen diagnosis quality, and the establishment of reference levels of activity. For these reasons, the Radiological Protection staff of Cuban Institute of Nephrology's Nuclear Medicine Service, where morpho functional renal studies are carried out, 70% on infants and young children, started a research on that way. Thus, because their biggest incidence, 99m Tc -DMSA renal gammagraphy studies were chosen, using a General Electric 400 AT Planar Gamma Camera. Studied sample was randomly selected, including adults (12 peoples) and children (23); divided into 4 groups, lessen given dose step by step. Other items were kept in mind in the research, such age, weight, time delayed between administrations and image getting, getting time of each view and total time of the study, as well as radiopharmaceuticals quality and Gamma Camera performance. Image quality was evaluated for each case, using both, objective and subjective criteria. Objective evaluation was done by using contrast/noise ratios and variance of the random noise. They were used to develop clustering and discriminant analysis over the independent variables to detect groups with differentiated image quality from the physical and mathematical point of view. Subjective evaluation was performed using the criteria of two expert observers who had no information about the activity levels used. They evaluated image quality separately, giving a good, regular or bad evaluation for each image. As a conclusion, we found that it is possible to reduce the given activities in 50% and thus, indirectly, to reduce doses for workers and for the public. Additionally, we propose a methodology for the establishment of reference levels for 99m Tc -DMSA renal gammagraphy studies in Cuba, both, for adults and paediatric patients. (author)

  10. Dose coefficients for individual occupationally exposed

    International Nuclear Information System (INIS)

    2005-11-01

    This Regulation refers to the requirements of the Regulation CNEN-NN.3.01, 'Basic Act of Radiological Protection', aiming its application to the dose calculation, with purposes of conformity verification with limits and restrictions of doses and level of reference for individual occupationally exposed, according to the express in its section 5

  11. EPA Region 1 Coast Guard Jurisdictional Boundary - Polygons

    Data.gov (United States)

    U.S. Environmental Protection Agency — Jurisdictional boundary between EPA and Coast Guard for EPA Region I. Created from 1:100000 USGS DLGs with greater detail drawn from 1:24000 commercial street data...

  12. EPA Region 1 Coast Guard Jurisdictional Boundary - Arcs

    Data.gov (United States)

    U.S. Environmental Protection Agency — Jurisdictional boundary between EPA and Coast Guard for EPA Region I. Created from 1:100000 USGS DLGs with greater detail drawn from 1:24000 commercial street data...

  13. Cloud-based CT dose monitoring using the DICOM-structured report. Fully automated analysis in regard to national diagnostic reference levels

    International Nuclear Information System (INIS)

    Boos, J.; Rubbert, C.; Heusch, P.; Lanzman, R.S.; Aissa, J.; Antoch, G.; Kroepil, P.

    2016-01-01

    To implement automated CT dose data monitoring using the DICOM-Structured Report (DICOM-SR) in order to monitor dose-related CT data in regard to national diagnostic reference levels (DRLs). Materials and Methods: We used a novel in-house co-developed software tool based on the DICOM-SR to automatically monitor dose-related data from CT examinations. The DICOM-SR for each CT examination performed between 09/2011 and 03/2015 was automatically anonymized and sent from the CT scanners to a cloud server. Data was automatically analyzed in accordance with body region, patient age and corresponding DRL for volumetric computed tomography dose index (CTDI vol ) and dose length product (DLP). Results: Data of 36 523 examinations (131 527 scan series) performed on three different CT scanners and one PET/CT were analyzed. The overall mean CTDI vol and DLP were 51.3 % and 52.8 % of the national DRLs, respectively. CTDI vol and DLP reached 43.8 % and 43.1 % for abdominal CT (n = 10 590), 66.6 % and 69.6 % for cranial CT (n = 16 098) and 37.8 % and 44.0 % for chest CT (n = 10 387) of the compared national DRLs, respectively. Overall, the CTDI vol exceeded national DRLs in 1.9 % of the examinations, while the DLP exceeded national DRLs in 2.9 % of the examinations. Between different CT protocols of the same body region, radiation exposure varied up to 50 % of the DRLs. Conclusion: The implemented cloud-based CT dose monitoring based on the DICOM-SR enables automated benchmarking in regard to national DRLs. Overall the local dose exposure from CT reached approximately 50 % of these DRLs indicating that DRL actualization as well as protocol-specific DRLs are desirable. The cloud-based approach enables multi-center dose monitoring and offers great potential to further optimize radiation exposure in radiological departments.

  14. Career paths through the U.S. EPA

    Science.gov (United States)

    In a recent survey of employee satisfaction, the U.S. EPA was ranked 6th of the 30 large federal agencies that were surveyed (http://data.bestplacestowork.org). I have been working as a post doc at the EPA since receiving my Ph.D. in ecological physiology from the University of ...

  15. 76 FR 46805 - Notice of Utah Adoption by Reference of the Pesticide Container Containment Rule

    Science.gov (United States)

    2011-08-03

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9447-8] Notice of Utah Adoption by Reference of the Pesticide Container Containment Rule AGENCY: Environmental Protection Agency (EPA). ACTION: Notice. SUMMARY: This... Pesticide Container Containment (PCC) Rule regulations. In accordance with State of Utah Agricultural Code...

  16. EPA Scientific Knowledge Management Assessment and ...

    Science.gov (United States)

    A series of activities have been conducted by a core group of EPA scientists from across the Agency. The activities were initiated in 2012 and the focus was to increase the reuse and interoperability of science software at EPA. The need for increased reuse and interoperability is linked to the increased complexity of environmental assessments in the 21st century. This complexity is manifest in the form of problems that require integrated multi-disciplinary solutions. To enable the means to develop these solutions (i.e., science software systems) it is necessary to integrate software developed by disparate groups representing a variety of science domains. Thus, reuse and interoperability becomes imperative. This report briefly describes the chronology of activities conducted by the group of scientists to provide context for the primary purpose of this report, that is, to describe the proceedings and outcomes of the latest activity, a workshop entitled “Workshop on Advancing US EPA integration of environmental and information sciences”. The EPA has been lagging in digital maturity relative to the private sector and even other government agencies. This report helps begin the process of improving the agency’s use of digital technologies, especially in the areas of efficiency and transparency. This report contributes to SHC 1.61.2.

  17. Conversion of ICRP male reference phantom to polygon-surface phantom

    Science.gov (United States)

    Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi

    2013-10-01

    The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (original ICRP reference phantoms, it is believed that the polygon-surface version of ICRP reference phantoms properly developed will not only provide the same or similar dose values (say, difference <5 or 10%) for highly penetrating radiations, but also provide correct dose values for the weakly penetrating

  18. Threshold-driven optimization for reference-based auto-planning

    Science.gov (United States)

    Long, Troy; Chen, Mingli; Jiang, Steve; Lu, Weiguo

    2018-02-01

    We study threshold-driven optimization methodology for automatically generating a treatment plan that is motivated by a reference DVH for IMRT treatment planning. We present a framework for threshold-driven optimization for reference-based auto-planning (TORA). Commonly used voxel-based quadratic penalties have two components for penalizing under- and over-dosing of voxels: a reference dose threshold and associated penalty weight. Conventional manual- and auto-planning using such a function involves iteratively updating the preference weights while keeping the thresholds constant, an unintuitive and often inconsistent method for planning toward some reference DVH. However, driving a dose distribution by threshold values instead of preference weights can achieve similar plans with less computational effort. The proposed methodology spatially assigns reference DVH information to threshold values, and iteratively improves the quality of that assignment. The methodology effectively handles both sub-optimal and infeasible DVHs. TORA was applied to a prostate case and a liver case as a proof-of-concept. Reference DVHs were generated using a conventional voxel-based objective, then altered to be either infeasible or easy-to-achieve. TORA was able to closely recreate reference DVHs in 5-15 iterations of solving a simple convex sub-problem. TORA has the potential to be effective for auto-planning based on reference DVHs. As dose prediction and knowledge-based planning becomes more prevalent in the clinical setting, incorporating such data into the treatment planning model in a clear, efficient way will be crucial for automated planning. A threshold-focused objective tuning should be explored over conventional methods of updating preference weights for DVH-guided treatment planning.

  19. The preparation and characterization of a loess sediment reference material for QC/QA of the annual radiation dose determination in luminescence dating

    International Nuclear Information System (INIS)

    De Corte, F.; De Wispelaere, A.; Vandenberghe, D.; Hossain, S.M.; Van den haute, P.

    2005-01-01

    Of crucial importance for obtaining reliable results in the luminescence dating of sediments, is the accurate and precise assessment of both the palaeodose and the annual radiation dose [cf the age equation: luminescence-age (ka) = palaeodose (Gray)/annual radiation dose (Gray.ka -1 )]. Clearly, for QC/QA of the annual radiation dose determination, a sediment reference material - not readily available up to now - would be highly useful. Therefore, in the present work a loess sediment was prepared and characterized with well-defined K, Th and U contents (the radiation dose being built up mainly by 40 K, and by 232 Th and 235,238 U and their decay daughters) and - otherwise expressed - alpha, beta, gamma and total radiation dose-rates. The material, a fine-grained aeolian loess sediment deposited in the Young-Pleistocene (Weichselian), a part of the Quaternary, was collected at Volkegem, Belgium. At the sampling site, NaI(Tl) field gamma-ray spectrometry was performed, yielding - via comparison with the 'Heidelberg calibration block' - concentrations (wet loess weight) for K, Th and U. About 14 kg material was brought to the laboratory and kept for ∼1 week at 110 degree C until constant weight (water content ≅14%). Then, the dried loess was subject to agate ball milling so as to pass through a 50 μm sieve. The ∼12 kg powder obtained in this way was homogenized both in a turbula mixer and manually. For the thus prepared loess material, good homogeneity for its K, Th and U content was found, as investigated via k 0 -INAA. For the final concentration and radiation dose-rate characterization, use was made of (next to NaI(Tl) field gamma-ray spectrometry and k 0 -INAA): extended energy-range low-background Ge gamma-ray spectrometry (also showing that the 232 Th and 238 U decay series were in secular equilibrium), thick source ZnS alpha-counting and GM beta-counting. For the latter', the conversion factors 'beta count-rate mutually implies radiation dose-rate' were

  20. Technical support for the EPA cleanup rule on radioactively contaminated sites

    Energy Technology Data Exchange (ETDEWEB)

    Hull, H.B.; Newman, A.; Wolbarst, A.B. [Environmental Protection Agency, Washington, DC (United States)] [and others

    1995-12-31

    The U.S. Environmental Protection Agency (EPA) is developing a radiation site cleanup regulation for the protection of the public from radionuclide contamination at sites that are to be cleaned up and released for public use. The regulation will apply to sites under the control of Federal agencies, and to sites licensed by the Nuclear Regulatory Commission (NRC) or NRC Agreement States. The agency is therefore conducting a comprehensive technical analysis aimed at developing information that will be used to support the rule. This presentation describes the regulation and the approach developed to determine how radiological health impacts and volumes of soil requiring remediation vary as functions of the possible cleanup dose or risk level.

  1. Proceedings of the workshop on review of dose modeling methods for demonstration of compliance with the radiological criteria for license termination

    International Nuclear Information System (INIS)

    Nicholson, T.J.; Parrott, J.D.

    1998-05-01

    The workshop was one in a series to support NRC staff development of guidance for implementing the final rule on ''Radiological Criteria for License Termination.'' The workshop topics included discussion of: dose models used for decommissioning reviews; identification of criteria for evaluating the acceptability of dose models; and selection of parameter values for demonstrating compliance with the final rule. The 2-day public workshop was jointly organized by RES and NMSS staff responsible for reviewing dose modeling methods used in decommissioning reviews. The workshop was noticed in the Federal Register (62 FR 51706). The workshop presenters included: NMSS and RES staff, who discussed both dose modeling needs for licensing reviews, and development of guidance related to dose modeling and parameter selection needs; DOE national laboratory scientists, who provided responses to earlier NRC staff-developed questions and discussed their various Federally-sponsored dose models (i.e., DandD, RESRAD, and MEPAS codes); and an EPA scientist, who presented details on the EPA dose assessment model (i.e., PRESTO code). The workshop was formatted to provide opportunities for the attendees to observe computer demonstrations of the dose codes presented. More than 120 workshop attendees from NRC Headquarters and the Regions, Agreement States; as well as industry representatives and consultants; scientists from EPA, DOD, DNFSB, DOE, and the national laboratories; and interested members of the public participated. A complete transcript of the workshop, including viewgraphs and attendance lists, is available in the NRC Public Document Room. This NUREG/CP documents the formal presentations made during the workshop, and provides a preface outlining the workshop's focus, objectives, background, topics and questions provided to the invited speakers, and those raised during the panel discussion. NUREG/CP-0163 also provides technical bases supporting the development of decommissioning

  2. Derivation of a reference dose and drinking water equivalent level for 1,2,3-trichloropropane.

    Science.gov (United States)

    Tardiff, Robert G; Carson, M Leigh

    2010-06-01

    In some US potable water supplies, 1,2,3-trichloropropane (TCP) has been present at ranges of non-detect to less than 100 ppb, resulting from past uses. In subchronic oral studies, TCP produced toxicity in kidneys, liver, and other tissues. TCP administered by corn oil gavage in chronic studies produced tumors at multiple sites in rats and mice; however, interpretation of these studies was impeded by substantial premature mortality. Drinking water equivalent levels (DWELs) were estimated for a lifetime of consumption by applying biologically-based safety/risk assessment approaches, including Monte Carlo techniques, and with consideration of kinetics and modes of action, to possibly replace default assumptions. Internationally recognized Frameworks for human relevance of animal data were employed to interpret the findings. Calculated were a reference dose (=39 microg/kg d) for non-cancer and Cancer Values (CV) (=10-14 microg/kg d) based on non-linear dose-response relationships for mutagenicity as a precursor of cancer. Lifetime Average Daily Intakes (LADI) are 3130 and 790-1120 microg/person-d for non-cancer and cancer, respectively. DWELs, estimated by applying a relative source contribution (RSC) of 50% to the LADIs, are 780 and 200-280 microg/L for non-cancer and cancer, respectively. These DWELs may inform establishment of formal/informal guidelines and standards to protect public health. Copyright 2010 Elsevier Ltd. All rights reserved.

  3. EPA'S strategy to reduce risk of radon

    International Nuclear Information System (INIS)

    Page, S.

    1993-01-01

    The Indoor Radon Abatement Act of 1988 (IRAA) directed EPA to undertake a variety of activities to address the growing public concern over dangers posed by exposure to indoor radon. Among other requirements, the law directed the Agency to study radon levels, evaluate mitigation methods, establish proficiency programs, assist states with program development, develop training centers, and provide public information. EPA has developed and implemented programs to address each of the key provisions of this statute. This paper presents EPA's broad national strategy to reduce radon risks. It combines and reinforces EPA's basic foundation, including its guiding policies and cooperative partnerships, with an overall management approach and focus for the future. The paper starts with an overview that introduces the strategy's four key elements: underlying policies and scientific principles, a decentralized system of states and other partners for targeting the public, multiple strategies for achieving radon risk reduction, and a strong focus on five key program priorities. This paper then discusses each of these elements in more detail and describes how they interact to guide future efforts and directions of the Agency

  4. Nonattainment Areas in Louisiana, Geographic NAD83, EPA (2006) [Nonattainment_LA_EPA_2006

    Data.gov (United States)

    Louisiana Geographic Information Center — EPA Region 6 NonAttainment Areas in Louisiana, current as of May 2006. This shapefile contains parish boundaries and attributes that determine whether the parishes...

  5. Regulation of higher-activity NARM wastes by EPA

    International Nuclear Information System (INIS)

    Bandrowski, M.S.

    1988-01-01

    The US Environmental Protection Agency (EPA) is currently developing standards for the disposal of low-level radioactive waste (LLW). As part of this Standard, EPA is including regulations for the disposal of naturally occurring and accelerator-produced radioactive material (NARM) wastes not covered under the Atomic Energy Act (AEA). The regulations will cover only higher-activity NARM wastes, defined as NARM waste with specific activity exceeding two nanocuries per gram. The proposed regulations will specify that NARM wastes exceeding the above limits, except for specific exempted items, must be disposed of in regulated radioactive waste disposal facilities. The proposed EPA regulations for NARM wastes will be discussed, as well as the costs and benefits of the regulation, how it will be implemented by EPA, and the rationale for covering only higher-activity NARM wastes exceeding two nanocuries per gram

  6. EPA's Efforts in Eurasia

    Science.gov (United States)

    EPA has been collaborating with Russia, Central Asia, the Caucasus and Ukraine for over 20 years and continues to work with their governments and non-governmental organizations on environment, science and technology issues.

  7. EPA Region 1 Environmentally Sensitive Areas

    Science.gov (United States)

    This coverage represents polygon equivalents of environmentally sensitive areas (ESA) in EPA Region I. ESAs were developed as part of an EPA headquarters initiative based on reviews of various regulatory and guidance documents, as well as phone interviews with federal/state/local government agencies and private organizations. ESAs include, but are not limited to, wetlands, biological resources, habitats, national parks, archaeological/historic sites, natural heritage areas, tribal lands, drinking water intakes, marinas/boat ramps, wildlife areas, etc.

  8. 40 CFR 725.370 - EPA review of the TME application.

    Science.gov (United States)

    2010-07-01

    ... unreasonable risk of injury to health and the environment as a result of test marketing. ... Marketing § 725.370 EPA review of the TME application. General procedures for review of all submissions... with test marketing activities after receipt of EPA approval. (c) In approving a TME application, EPA...

  9. Reference Man for Asians as well as for Europeans-A change in the ICRP concept of Reference Man

    International Nuclear Information System (INIS)

    Tanaka, Gi-ichiro

    1990-01-01

    ICRP Reference Man, according to the definition, is primarily for Caucasoid populations (Western Europeans and North Americans) that contribute only 13 per cent of the world population. A speculative world population dose will, assuming a uniform exposure all over the world at a level of 10 μSv, be 50 k man Sv in total. Of this, all regions of Caucasoid populations may contribute by 22 per cent maximum. Asian populations will share about 58 per cent (29 k man Sv) of the world population dose. About eighty per cents in total of the world population can be convered by scientific dose assessment, if Reference Man data for Asians are made available. Thus the importance of establishing Asian Reference Man should be evident. The important point of characteristics of Asians is that they are 'Vegetarians' as compared to Westerners, which suggests different pathways with respect to transfer of radionuclides from foods to the human body. Therefore it is required to determine accurate and suitable parameters relevant to dose assessment. Considering the above, contribution of Japan in science and technology to Asian countries with 'knowhows' accumulated may be of a most urgent matter. (author)

  10. EPA ENERGY STAR: Tackling Growth in Home Electronics and Small Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Marla Christine; Brown, Richard; Homan, Gregory

    2008-11-17

    Over a decade ago, the electricity consumption associated with home electronics and other small appliances emerged onto the global energy policy landscape as one of the fastest growing residential end uses with the opportunity to deliver significant energy savings. As our knowledge of this end use matures, it is essential to step back and evaluate the degree to which energy efficiency programs have successfully realized energy savings and where savings opportunities have been missed.For the past fifteen years, we have quantified energy, utility bill, and carbon savings for US EPA?s ENERGY STAR voluntary product labeling program. In this paper, we present a unique look into the US residential program savings claimed to date for EPA?s ENERGY STAR office equipment, consumer electronics, and other small household appliances as well as EPA?s projected program savings over the next five years. We present a top-level discussion identifying program areas where EPA?s ENERGY STAR efforts have succeeded and program areas where ENERGY STAR efforts did not successfully address underlying market factors, technology issues and/or consumer behavior. We end by presenting the magnitude of ?overlooked? savings.

  11. Privacy Act System of Records: Invention Reports Submitted to the EPA, EPA-38

    Science.gov (United States)

    Learn about the Invention Reports Submitted to the EPA System, including who is covered in the system, the purpose of data collection, routine uses for the system's records, and other security procedures.

  12. US EPA CARE Grants

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is a provisional dataset that contains point locations for the subset of Community Action for a Renewed Environment (CARE) grants given out by the US EPA. CARE...

  13. US EPA EJ Grants

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is a provisional dataset that contains point locations for all Environmental Justice (EJ) grants given out by the US EPA. There are many limitations to the data...

  14. Identification of dose-reduction techniques for BWR and PWR repetitive high-dose jobs

    International Nuclear Information System (INIS)

    Dionne, B.J.; Baum, J.W.

    1984-01-01

    As a result of concern about the apparent increase in collective radiation dose to workers at nuclear power plants, this project will provide information to industry in preplanning for radiation protection during maintenance operations. This study identifies Boiling Water Reactor (BWR) and Pressurized Water Reactor (PWR) repetitive jobs, and respective collective dose trends and dose reduction techniques. 3 references, 2 tables

  15. 77 FR 3152 - New Mexico: Final Authorization of State-Initiated Changes and Incorporation-by-Reference of...

    Science.gov (United States)

    2012-01-23

    ... relations, Penalties, Reporting and recordkeeping requirements, Water pollution control, Water supply... Mexico: Final Authorization of State-Initiated Changes and Incorporation-by-Reference of State Hazardous.... SUMMARY: During a review of New Mexico's regulations, the EPA identified a variety of State-initiated...

  16. CT patterns of fungal pulmonary infections of the lung: Comparison of standard-dose and simulated low-dose CT

    International Nuclear Information System (INIS)

    Christe, Andreas; Lin, Margaret C.; Yen, Andrew C.; Hallett, Rich L.; Roychoudhury, Kingshuk; Schmitzberger, Florian; Fleischmann, Dominik; Leung, Ann N.; Rubin, Geoffry D.; Vock, Peter; Roos, Justus E.

    2012-01-01

    Purpose: To assess the effect of radiation dose reduction on the appearance and visual quantification of specific CT patterns of fungal infection in immuno-compromised patients. Materials and methods: Raw data of thoracic CT scans (64 × 0.75 mm, 120 kVp, 300 reference mAs) from 41 consecutive patients with clinical suspicion of pulmonary fungal infection were collected. In 32 patients fungal infection could be proven (median age of 55.5 years, range 35–83). A total of 267 cuboids showing CT patterns of fungal infection and 27 cubes having no disease were reconstructed at the original and 6 simulated tube currents of 100, 40, 30, 20, 10, and 5 reference mAs. Eight specific fungal CT patterns were analyzed by three radiologists: 76 ground glass opacities, 42 ground glass nodules, 51 mixed, part solid, part ground glass nodules, 36 solid nodules, 5 lobulated nodules, 6 spiculated nodules, 14 cavitary nodules, and 37 foci of air-space disease. The standard of reference was a consensus subjective interpretation by experts whom were not readers in the study. Results: The mean sensitivity and standard deviation for detecting pathological cuboids/disease using standard dose CT was 0.91 ± 0.07. Decreasing dose did not affect sensitivity significantly until the lowest dose level of 5 mAs (0.87 ± 0.10, p = 0.012). Nodular pattern discrimination was impaired below the dose level of 30 reference mAs: specificity for fungal ‘mixed nodules’ decreased significantly at 20, 10 and 5 reference mAs (p < 0.05). At lower dose levels, classification drifted from ‘solid’ to ‘mixed nodule’, although no lesion was missed. Conclusion: Our simulation data suggest that tube current levels can be reduced from 300 to 30 reference mAs without impairing the diagnostic information of specific CT patterns of pulmonary fungal infections

  17. Derived reference doses for three compounds used in the photovoltaics industry: Copper indium diselenide, copper gallium diselenide, and cadmium telluride

    Energy Technology Data Exchange (ETDEWEB)

    Moskowitz, P.D.; Bernholc, N.; DePhillips, M.P.; Viren, J.

    1995-07-06

    Polycrystalline thin-film photovoltaic modules made from copper indium diselenide (CIS), copper gallium diselenide (CGS), and cadmium telluride (CdTe) arc nearing commercial development. A wide range of issues are being examined as these materials move from the laboratory to large-scale production facilities to ensure their commercial success. Issues of traditional interest include module efficiency, stability and cost. More recently, there is increased focus given to environmental, health and safety issues surrounding the commercialization of these same devices. An examination of the toxicological properties of these materials, and their chemical parents is fundamental to this discussion. Chemicals that can present large hazards to human health or the environment are regulated often more strictly than those that are less hazardous. Stricter control over how these materials are handled and disposed can increase the costs associated with the production and use of these modules dramatically. Similarly, public perception can be strongly influenced by the inherent biological hazard that these materials possess. Thus, this report: presents a brief background tutorial on how toxicological data are developed and used; overviews the toxicological data available for CIS, CGS and CdTe; develops ``reference doses`` for each of these compounds; compares the reference doses for these compounds with those of their parents; discusses the implications of these findings to photovoltaics industry.

  18. Science Inventory | US EPA

    Science.gov (United States)

    The Science Inventory is a searchable database of research products primarily from EPA's Office of Research and Development. Science Inventory records provide descriptions of the product, contact information, and links to available printed material or websites.

  19. Reference computations of public dose and cancer risk from airborne releases of uranium and Class W plutonium

    International Nuclear Information System (INIS)

    Peterson, V.L.

    1995-01-01

    This report presents ''reference'' computations that can be used by safety analysts in the evaluations of the consequences of postulated atmospheric releases of radionuclides from the Rocky Flats Environmental Technology Site. These computations deal specifically with doses and health risks to the public. The radionuclides considered are Class W Plutonium, all classes of Enriched Uranium, and all classes of Depleted Uranium. (The other class of plutonium, Y, was treated in an earlier report.) In each case, one gram of the respirable material is assumed to be released at ground leveL both with and without fire. The resulting doses and health risks can be scaled to whatever amount of release is appropriate for a postulated accident being investigated. The report begins with a summary of the organ-specific stochastic risk factors appropriate for alpha radiation, which poses the main health risk of plutonium and uranium. This is followed by a summary of the atmospheric dispersion factors for unfavorable and typical weather conditions for the calculation of consequences to both the Maximum Offsite Individual and the general population within 80 km (50 miles) of the site

  20. Poster: Report Fraud Waste and Abuse to the EPA OIG Hotline

    Science.gov (United States)

    The EPA OIG hotline receives complaints of fraud, waste, and abuse in EPA and U.S. Chemical Safety Board programs and operations including mismanagement or violations of law, rules, or regulations by EPA employees or program participants.

  1. Collaborating with EPA through the Federal Technology Transfer Act

    Science.gov (United States)

    Under the Federal Technology Transfer Act (FTTA), EPA can collaborate with external parties on research projects, and share research materials. Learn more about the types of partnerships the EPA offers.

  2. An Assessment of Cs-137, R-226 and Pa-239, 240 doses for aquatic and terrestrial reference organisms in Poland

    International Nuclear Information System (INIS)

    Krajewski, P.; Suplinska, M.; Rosiak, I.

    2004-01-01

    The doses assessment for aquatic and terrestrial reference organisms was performed, based on the methodology elaborated by U.S. Department of Energy. Four organism types and their corresponding dose limits were used, and the principal exposure pathways were considered for aquatic animal, riparian animal, terrestrial plant, and terrestrial animal organism types respectively. Terrestrial rodent (apodemus flavicollis), Baltic Sea fish (cod, sprat, herring, plaice) and crustaceans (Sanduria entomon and Mytilus edulis) were taken in to special consideration. In the first screening approach the annual doses from 137Cs and 239Pu (bomb-tests-fallout and Czarnobyl origin) and 226Ra (natural radionuclide) to biota were calculated at average, minimum and maximum concentrations of these radionuclides observed in soil, water, and sediment using the default bioaccumulation factors as well as lumped parameters values recommended by DOE Standard. The concentrations of 137Cs measured in the most contaminated region in Poland (Stare Olesno 380 Bqxkg-1 d.w.) and the concentrations of 226Ra for Southern regions of Poland with elevated levels of 226Ra in soil (100 B kg-1 d.w.) were taken in the dose assessment for terrestrial animals. The concentrations of 137Cs and 239Pu and 226Ra determined in see water and bottom sediments from two sub-areas (Gdansk Basin and Bornholm Basin) were used in the dose assessment for aquatic biota. In the second ''site specific'' approach the average empirically measured concentrations of radionuclides in animal tissues were used. At the first approach the total maximal annual doses for terrestrial plants were less then one percent of the recommended dose limits ( 3600 mGyxy-1 ) and items for seawater organisms did not exceed a 40% of this limit whereas the total maximal annual doses for terrestrial animal were close to the recommended dose limit (360 mGyxy-1). It prompted to start supplementary site-specific biota dose assessment through site

  3. Hispanos en la EPA: Elias Rodríguez

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  4. Hispanos en la EPA: Sally Gutiérrez

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  5. EPA's Revised Interim Financial Assistance Conflict of Interest Policy

    Science.gov (United States)

    EPA has established the following revised interim policy governing disclosure of actual and potential conflicts of interest (COI Policy) by applicants for, and recipients of, federal financial assistance awards from EPA.

  6. Handbook of selected organ doses for projections common in pediatric radiology

    International Nuclear Information System (INIS)

    Rosenstein, M.; Beck, T.J.; Warner, G.G.

    1979-05-01

    This handbook contains data from which absorbed dose (mrad) to selected organs can be estimated for common projections in pediatric radiology. The organ doses are for three reference patients: a newborn (0 to 6 months), a 1-year old child, and a 5-year old child. One intent of the handbook is to permit the user to evaluate the effect on organ dose to these reference pediatric patients as a function of certain changes in technical parameters used in or among facilities. A second intent is to permit a comparison to be made of organ doses as a function of age. This comparison can be extended to a reference adult by referring to the previous Handbook of Selected Organ Doses fo Projections Common in Diagnostic Radiology, FDA 76-8031. Assignment of organ doses to individual pediatric patients using the Handbook data is not recommended unless the physical characteristics of the patient closely correlate with one of the three reference pediatric patients given in Appendix A

  7. IG Statement: Arthur A. Elkins, Jr., on OIG report Early Warning Report: Main EPA Headquarters Warehouse in Landover, Maryland, Requires Immediate EPA Attention

    Science.gov (United States)

    Statement of Inspector General Arthur A. Elkins, Jr., on the Office of Inspector General (OIG) report Early Warning Report: Main EPA Headquarters Warehouse in Landover, Maryland, Requires Immediate EPA Attention.

  8. 75 FR 51392 - New York: Incorporation by Reference of State Hazardous Waste Management Program

    Science.gov (United States)

    2010-08-20

    ... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 272 [EPA-R02-RCRA-2010-0249; FRL-9178-8] New York: Incorporation by Reference of State Hazardous Waste Management Program Correction In rule document 2010-18927 beginning on page 45489 in the issue of Tuesday, August 3, 2010, make the following correction: Appendix A...

  9. Specification of volume and dose in radiotherapy

    International Nuclear Information System (INIS)

    Levernes, S.

    1997-01-01

    As a result of a questionnaire about dose and volume specifications in radiotherapy in the Nordic countries, a group has been set up to propose common recommendations for these countries. The proposal is partly based on ICRU 50, but with major extensions. These extensions fall into three areas: patient geometry, treatment geometry, and dose specifications. For patient geometry and set-up one need alignment markings and anatomical reference points, the latter can be divided into internal and external reference points. These points are necessary to get relationships between coordinate systems related to patient and to treatment unit. For treatment geometry the main volume will be an anatomical target volume which just encompass the clinical target volume with all its variations and movements. This anatomical volume are the most suitable volume for prescription, optimization and reporting dose. A set-up margin should be added to the beam periphery in beams-eye-view to get the minimum size and shape of the beam. For dose specification the most important parameter for homogeneous dose distributions is the arithmetic mean of dose to the anatomical target volume together with its standard deviation. In addition the dose to the ICRU reference point should be reported for intercomparison, together with minimum and maximum doses or dose volume histograms for the anatomical target volume. (author)

  10. EPA's technical methodology for the development of cleanup regulations for radioactively-contaminated soils and buildings

    International Nuclear Information System (INIS)

    Hull, H.B.; Doehnert, M.; Wolbarst, A.; Mauro, J.J.; Ralston, L.

    1995-01-01

    The total number of sites contaminated with radionuclides in the United States is in the thousands. These sites range in size from corners of laboratories to sprawling nuclear weapons facilities covering many square miles of land. The U.S. Environmental Protection Agency (EPA) is proposing regulations for the protection of the public from radionuclide contamination at sites that are to be cleaned up and released for public use. The rule will apply to site under the control of Federal agencies, and to sites licensed by the Nuclear Regulatory Commission (NRC) or NRC Agreement States. In support of this rulemaking, EPA is conducting a comprehensive technical analysis which will provide information on the volumes of soil requiring remediation at various possible dose and risk levels. The analysis will also provide information at different cleanup levels on the number of potential adverse health effects among people living or working on or near a site following the cleanup of its radioactive contamination. This paper summarizes the overall approach for the technical analysis. (author)

  11. EPA Region 1 Coast Guard Jurisdictional Boundary - Polygons

    Science.gov (United States)

    Jurisdictional boundary between EPA and Coast Guard for EPA Region I. Created from 1:100000 USGS DLGs with greater detail drawn from 1:24000 commercial street data for Region I.This layer is used to determine which agency will be reponsible in the event of an oil spill.

  12. EPA Region 1 Coast Guard Jurisdictional Boundary - Arcs

    Science.gov (United States)

    Jurisdictional boundary between EPA and Coast Guard for EPA Region I. Created from 1:100000 USGS DLGs with greater detail drawn from 1:24000 commercial street data for Region I.This layer is used to determine which agency will be reponsible in the event of an oil spill.

  13. Notification: EPA Investments in Information Technology Products and Services

    Science.gov (United States)

    Project #OA-FY14-0307, June 10, 2014. The U.S. Environmental Protection Agency (EPA) Office oflnspector General (OIG) plans to begin preliminary research on the EPA's management of information technology (IT) investments.

  14. US EPA's Ecological Risk Assessment Support Center ...

    Science.gov (United States)

    BackgroundThe ERASC provides technical information and addresses scientific questions of concern or interest on topics relevant to ecological risk assessment at hazardous waste sites for EPA's Office of Solid Waste and Emergency Response (OSWER) personnel and the Office of Resource Conservation and Recovery (ORCR) staff. Requests are channeled to ERASC through the Ecological Risk Assessment Forum (ERAF). To assess emerging and complex scientific issues that require expert judgment, the ERASC relies on the expertise of scientists and engineers located throughout EPA's Office of Research and Development (ORD) labs and centers.ResponseERASC develops responses that reflect the state of the science for ecological risk assessment and also provides a communication point for the distribution of the responses to other interested parties. For further information, contact Ecology_ERASC@epa.gov or call 513-569-7940.

  15. Radiation doses to patients from x-ray examinations - development from 2005 to 2008

    International Nuclear Information System (INIS)

    Leitz, Wolfram; Almen, Anja

    2010-04-01

    Data has been compiled and analyzed and compared with the earlier reports. Radiation doses were tested for possible links with various parameters (eg type of x-ray equipment, image recording systems, different technique factors). In conventional x-ray examinations radiation doses were, for equipment with direct digital image receivers, in average 30% lower than for those with photo plates. Mammography doses were, with one exception, the same for all types of equipment and video receivers. The CT-examinations had a small trend for higher doses for new equipment as compared to earlier. Use of exposure automation did not affect radiation doses. Compared with 2006, the doses of conventional surveys decreased by an average of 21%. One third of this dose reduction can be attributed the introduction of direct digital system whose use grew by about 30%. Most of the dose reduction can be attributed to the actions carried out to lower the dose of the reference level. Doses for the CT scan showed only a weak downwards trend. Mammography Doses decreased by an average of just over 10% a large part dependent on increased number of Sectra equipment. The system of diagnostic reference levels have again shown to have positive influence on the radiation level at the x-ray examinations, this is most pronounced for conventional radiography. There is still a large potential for dose reduction, and a measure to achieve this is to reduce the current reference levels. Very few diagnostic Standard doses are higher than the reference level. A reduction of the reference levels corresponding to the third quartile of dose distribution could lead further dose decrease of 10-20%. The corresponding reduction in dose should be done also for the DT and mammograms when lowering the reference level, there are few standard doses higher than the current reference levels

  16. EPA Web Training Classes

    Science.gov (United States)

    Scheduled webinars can help you better manage EPA web content. Class topics include Drupal basics, creating different types of pages in the WebCMS such as document pages and forms, using Google Analytics, and best practices for metadata and accessibility.

  17. Proceedings: EPRI Workshop 2 -- Technical basis for EPA HLW disposal criteria

    International Nuclear Information System (INIS)

    Rogers, V.

    1993-03-01

    The Electric Power Research Institute (EPRI) sponsored this workshop to address the scientific and technical issues underlying the regulatory criteria, or standard, for the disposal of spent nuclear fuel, high-level radioactive waste, and transuranic waste, commonly referred to collectively as high-level waste (HLW). These regulatory criteria were originally promulgated by the US Environmental Protection Agency (EPA) in 40 CFR Part 191 in 1985. However, significant portions of the regulation were remanded by the Ninth Circuit Court of Appeals in 1987. This is the second of two workshops. Topics discussed include: gas pathway; individual and groundwater protection; human intrusion; population protection; performance; TRU conversion factors and discussions. Individual projects re processed separately for the databases

  18. A pilot effectiveness study of the Enhancing Parenting Skills (EPaS) 2014 programme for parents of children with behaviour problems: study protocol for a randomised controlled trial

    OpenAIRE

    Williams, Margiad Elen; Hutchings, Judy

    2015-01-01

    Background The Enhancing Parenting Skills (EPaS) 2014 programme is a home-based, health visitor-delivered parenting support programme for parents of children with identified behaviour problems. This trial aims to evaluate the effectiveness of the EPaS 2014 programme compared to a waiting-list treatment as usual control group. Methods/Design This is a pragmatic, multicentre randomised controlled trial. Sixty health visitors will each be asked to identify two families that have a child scoring ...

  19. SU-G-BRB-14: Uncertainty of Radiochromic Film Based Relative Dose Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Devic, S; Tomic, N; DeBlois, F; Seuntjens, J [McGill University, Montreal, QC (Canada); Lewis, D [RCF Consulting, LLC, Monroe, CT (United States); Aldelaijan, S [King Faisal Specialist Hospital & Research Center, Riyadh (Saudi Arabia)

    2016-06-15

    Purpose: Due to inherently non-linear dose response, measurement of relative dose distribution with radiochromic film requires measurement of absolute dose using a calibration curve following previously established reference dosimetry protocol. On the other hand, a functional form that converts the inherently non-linear dose response curve of the radiochromic film dosimetry system into linear one has been proposed recently [Devic et al, Med. Phys. 39 4850–4857 (2012)]. However, there is a question what would be the uncertainty of such measured relative dose. Methods: If the relative dose distribution is determined going through the reference dosimetry system (conversion of the response by using calibration curve into absolute dose) the total uncertainty of such determined relative dose will be calculated by summing in quadrature total uncertainties of doses measured at a given and at the reference point. On the other hand, if the relative dose is determined using linearization method, the new response variable is calculated as ζ=a(netOD)n/ln(netOD). In this case, the total uncertainty in relative dose will be calculated by summing in quadrature uncertainties for a new response function (σζ) for a given and the reference point. Results: Except at very low doses, where the measurement uncertainty dominates, the total relative dose uncertainty is less than 1% for the linear response method as compared to almost 2% uncertainty level for the reference dosimetry method. The result is not surprising having in mind that the total uncertainty of the reference dose method is dominated by the fitting uncertainty, which is mitigated in the case of linearization method. Conclusion: Linearization of the radiochromic film dose response provides a convenient and a more precise method for relative dose measurements as it does not require reference dosimetry and creation of calibration curve. However, the linearity of the newly introduced function must be verified. Dave Lewis

  20. Analysis of workers' dose records from the Greek Dose Registry Information System

    International Nuclear Information System (INIS)

    Kamenopoulou, V.; Dimitriou, P.; Proukakis, Ch.

    1995-01-01

    The object of this work is the study of the individual film badge annual dose information of classified workers in Greece, monitored and assessed by the central dosimetry service of the Greek Atomic Energy Commission. Dose summaries were recorded and processed by the Dose Registry Information System. The statistical analysis refers to the years 1989-93 and deals with the distribution of individuals in the occupational groups, the mean annual dose, the collective dose, the distribution of the dose over the different specialties and the number of workers that have exceeded any of the established dose limits. Results concerning the annual dose summaries, demonstrate a year-by-year reduction in the mean individual dose to workers in the health sector. Conversely, exposures in the industrial sector did not show any decreasing tendency during the period under consideration. (Author)

  1. IRIS Toxicological Review of 2,2',4,4'-Tetrabromodiphenyl ...

    Science.gov (United States)

    The U.S. EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessments of congeners of polybrominated diphenyl ethers (PDBEs), this review is about 2,2',4,4'-Tetrabromodiphenyl Ether, or commonly referred to as tetraBDE (BDE-47). Following the external peer review this assessment will appear in the Integrated Risk Information System (IRIS) database. Peer review will ensure that science is used credibly and appropriately in derivation of the dose-response assessments and toxicological characterization. EPA is updating the Integrated Risk Information System (IRIS) health assessments for the PBDEs.

  2. Japanese reference man 1988, 3

    International Nuclear Information System (INIS)

    Tanaka, Gi-ichiro

    1988-01-01

    Quantitative description of physical properties and other characteristics of the human body is one of the basic data for estimating dose equivalent and calculating Annual Limit on Intake of radionuclides. The exact mass weight of organs and tissues are measured from about 1000 autopsy cases of normal Japanese adults and physical properties are obtained from recent Japanese Government publications. Japanese (Asian) Reference Man is completed by establishing the Normal Japanese, harmonizing with Caucasian Reference Man and coinciding with the ICRP Reference Man Task Group members concept. (author)

  3. Age-dependent dose coefficients for tritium in Asian populations

    Energy Technology Data Exchange (ETDEWEB)

    Trivedi, A

    1999-10-01

    The International Commission on Radiological Protection (ICRP) Publications 56 (1989) and 67 (1993) have prescribed the biokinetic models and age-dependent dose coefficients for tritiated water and organically bound tritium. The dose coefficients are computed from values selected to specify the anatomical, morphological and physiological characteristics of a three-month-old, one-year-old, five-year-old, 10-year-old, 15-year-old and adult (Reference Man) Caucasian living in North America and Western Europe. However, values for Reference Man and other age groups are not directly applicable to Asians, because of differences in race, custom, dietary habits and climatic conditions. An Asian Man model, including five age groups, has been proposed by Tanaka and Kawamura (1996, 1998) for use in internal dosimetry. The basic concept of the ICRP Reference Man and the system describing body composition in ICRP Publication 23 (1975) were used. Reference values for Asians were given for the body weight and height, the mass of soft tissue, the mass of body water and the daily fluid balance, and are used to compute the dose coefficients for tritium. The age-dependent dose coefficients for Asians for tritiated water intakes are smaller by 20 to 30% of the currently prescribed values (Trivedi, 1998). The reduction in the dose coefficient values is caused by the increased daily fluid balance among Asians. The dose coefficient for tritiated water is 1.4 x 10{sup -11} Sv Bq{sup -1} for Asian Man compared to 2.0 x 10{sup -11} Sv Bq{sup -1} for Reference Man. The dose coefficients for organically bound tritium are only marginally different from those of the ICRP values. The dose coefficient for organically bound tritium for Asian Man is 4.0 x 10{sup -11} Sv Bq{sup -11} compared to 4.6 x 10{sup -11} Sv Bq{sup -1} for Reference Man. (author)

  4. Age-dependent dose coefficients for tritium in Asian populations

    International Nuclear Information System (INIS)

    Trivedi, A.

    1999-10-01

    The International Commission on Radiological Protection (ICRP) Publications 56 (1989) and 67 (1993) have prescribed the biokinetic models and age-dependent dose coefficients for tritiated water and organically bound tritium. The dose coefficients are computed from values selected to specify the anatomical, morphological and physiological characteristics of a three-month-old, one-year-old, five-year-old, 10-year-old, 15-year-old and adult (Reference Man) Caucasian living in North America and Western Europe. However, values for Reference Man and other age groups are not directly applicable to Asians, because of differences in race, custom, dietary habits and climatic conditions. An Asian Man model, including five age groups, has been proposed by Tanaka and Kawamura (1996, 1998) for use in internal dosimetry. The basic concept of the ICRP Reference Man and the system describing body composition in ICRP Publication 23 (1975) were used. Reference values for Asians were given for the body weight and height, the mass of soft tissue, the mass of body water and the daily fluid balance, and are used to compute the dose coefficients for tritium. The age-dependent dose coefficients for Asians for tritiated water intakes are smaller by 20 to 30% of the currently prescribed values (Trivedi, 1998). The reduction in the dose coefficient values is caused by the increased daily fluid balance among Asians. The dose coefficient for tritiated water is 1.4 x 10 -11 Sv Bq -1 for Asian Man compared to 2.0 x 10 -11 Sv Bq -1 for Reference Man. The dose coefficients for organically bound tritium are only marginally different from those of the ICRP values. The dose coefficient for organically bound tritium for Asian Man is 4.0 x 10 -11 Sv Bq -11 compared to 4.6 x 10 -11 Sv Bq -1 for Reference Man. (author)

  5. Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma

    International Nuclear Information System (INIS)

    Candela-Juan, Cristian; Perez-Calatayud, Jose; Ballester, Facundo; Rivard, Mark J.

    2013-01-01

    Purpose: The aim of this study was to obtain equivalent doses in radiosensitive organs (aside from the bladder and rectum) when applying high-dose-rate (HDR) brachytherapy to a localized prostate carcinoma using 60 Co or 192 Ir sources. These data are compared with results in a water phantom and with expected values in an infinite water medium. A comparison with reported values from proton therapy and intensity-modulated radiation therapy (IMRT) is also provided. Methods: Monte Carlo simulations in Geant4 were performed using a voxelized phantom described in International Commission on Radiological Protection (ICRP) Publication 110, which reproduces masses and shapes from an adult reference man defined in ICRP Publication 89. Point sources of 60 Co or 192 Ir with photon energy spectra corresponding to those exiting their capsules were placed in the center of the prostate, and equivalent doses per clinical absorbed dose in this target organ were obtained in several radiosensitive organs. Values were corrected to account for clinical circumstances with the source located at various positions with differing dwell times throughout the prostate. This was repeated for a homogeneous water phantom. Results: For the nearest organs considered (bladder, rectum, testes, small intestine, and colon), equivalent doses given by 60 Co source were smaller (8%–19%) than from 192 Ir. However, as the distance increases, the more penetrating gamma rays produced by 60 Co deliver higher organ equivalent doses. The overall result is that effective dose per clinical absorbed dose from a 60 Co source (11.1 mSv/Gy) is lower than from a 192 Ir source (13.2 mSv/Gy). On the other hand, equivalent doses were the same in the tissue and the homogeneous water phantom for those soft tissues closer to the prostate than about 30 cm. As the distance increased, the differences of photoelectric effect in water and soft tissue, and appearance of other materials such as air, bone, or lungs, produced

  6. Notification: Audit of Certain EPA Electronic Records Management Practices

    Science.gov (United States)

    Project #OA-FY13-0113, December 13, 2012. This memorandum is to notify you that the U.S. Environmental Protection Agency (EPA), Office of Inspector General, plans to begin an audit of certain EPA electronic records management practices.

  7. Evaluation of doses and risks from different decontamination and decommissioning strategies using the PRESTO-II methodology

    International Nuclear Information System (INIS)

    Fields, D.E.

    1986-01-01

    The PRESTO-II methodology may be applied to evaluate doses and health risks from a variety of decontamination and decommissioning activities. This methodology has been implemented in the form of a computer code that has been applied to several sites, and that has been extensively documented. Radionuclide inventories are specified as separate contamination sources either present on the ground surface, covered by non-radioactive soils but lying above the water table, suspended in the atmosphere, or dissolved in surface waters. Hydrologic transport mechanisms considered in the PRESTO-II methodology include chemical exchange, ponding and overflow, surface water transport, groundwater transport, and pumping contaminated groundwater from wells. Varied scenarios of water usage are treated. Atmospheric inputs are based on both resuspension factor and resuspension rate approaches, with inhalation and immersion doses based on a Gaussian plume transport calculation. Site activities that are considered include land clearing, farming, and residing on the site. Exposure and dose calculations are derived from the US Nuclear Regulatory Commission Reg. Guide 1.109 approach, while risk calculations use a life-table approach developed for the US Environmental Protection Agency (EPA). Internal dose conversion factors are taken from ICRP 26 and 30, while risk conversion factors are values suggested by EPA. 19 refs., 2 figs., 1 tab

  8. Comparison BIPM.RI(I)-K8 of high dose-rate Ir-192 brachytherapy standards for reference air kerma rate of the VSL and the BIPM

    DEFF Research Database (Denmark)

    Alvarez, J.T.; De Pooter, J.A.; Andersen, Claus E.

    2014-01-01

    An indirect comparison of the standards for reference air kerma rate for 192Ir high dose rate brachytherapy sources of the Dutch Metrology Institute (VSL), The Netherlands, and of the Bureau International des Poids et Mesures (BIPM) was carried out at the VSL in November 2009. The comparison resu...

  9. Comparison BIPM.RI(I)-K8 of high dose-rate Ir-192 brachytherapy standards for reference air kerma rate of the PTB and the BIPM

    International Nuclear Information System (INIS)

    Kessler, C.; Allisy-Roberts, P.J.; Selbach, H.J.

    2015-01-01

    An indirect comparison of the standards for reference air kerma rate (RAKR) for 192 Ir high dose rate (HDR) brachytherapy sources of the Physikalisch-Technische Bundesanstalt (PTB), Germany, and of the Bureau International des Poids et Mesures (BIPM) was carried out at the PTB in September 2011. The comparison result, based on the calibration coefficients for a transfer standard and expressed as a ratio of the PTB and the BIPM standards for reference air kerma rate, is 1.0003 with a combined standard uncertainty of 0.0099. (authors)

  10. 40 CFR 600.109-78 - EPA driving cycles.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false EPA driving cycles. 600.109-78 Section... Model Year Automobiles-Test Procedures § 600.109-78 EPA driving cycles. (a) The driving cycle to be... driving cycle to be utilized for generation of the highway fuel economy data is specified in this...

  11. What is correct: equivalent dose or dose equivalent

    International Nuclear Information System (INIS)

    Franic, Z.

    1994-01-01

    In Croatian language some physical quantities in radiation protection dosimetry have not precise names. Consequently, in practice either terms in English or mathematical formulas are used. The situation is even worse since the Croatian language only a limited number of textbooks, reference books and other papers are available. This paper compares the concept of ''dose equivalent'' as outlined in International Commission on Radiological Protection (ICRP) recommendations No. 26 and newest, conceptually different concept of ''equivalent dose'' which is introduced in ICRP 60. It was found out that Croatian terminology is both not uniform and unprecise. For the term ''dose equivalent'' was, under influence of Russian and Serbian languages, often used as term ''equivalent dose'' even from the point of view of ICRP 26 recommendations, which was not justified. Unfortunately, even now, in Croatia the legal unit still ''dose equivalent'' defined as in ICRP 26, but the term used for it is ''equivalent dose''. Therefore, in Croatian legislation a modified set of quantities introduced in ICRP 60, should be incorporated as soon as possible

  12. Eicosapentaenoic acid (EPA) efficacy for colorectal aberrant crypt foci (ACF): a double-blind randomized controlled trial

    International Nuclear Information System (INIS)

    Higurashi, Takuma; Ohkubo, Hidenori; Sakai, Eiji; Maeda, Shin; Morita, Satoshi; Natsumeda, Yutaka; Nagase, Hajime; Nakajima, Atsushi; Hosono, Kunihiro; Endo, Hiroki; Takahashi, Hirokazu; Iida, Hiroshi; Uchiyama, Takashi; Ezuka, Akiko; Uchiyama, Shiori; Yamada, Eiji

    2012-01-01

    dose, 2.7 g per day), and those in the placebo group shall receive oral placebo capsules thrice daily. After one month’s treatment with EPA/placebo, colonoscopic examination and polypectomy will be performed to evaluate the formation of ACF, and the cell-proliferative activity and cell-apoptotic activity in normal colorectal mucosa and colorectal polyps. This is the first study proposed to explore the effect of EPA against colorectal ACF formation in humans. This trial has been registered in the University hospital Medical Information Network (UMIN) Clinical Trials Registry as UMIN000008172

  13. EPA Collaboration with South Korea

    Science.gov (United States)

    EPA, the Ministry of Environment of Korea, and partner agencies in both countries cooperate to strengthen environmental governance, improve air and water quality, and reduce exposure to toxic chemicals.

  14. 40 CFR 2.205 - Final confidentiality determination by EPA legal office.

    Science.gov (United States)

    2010-07-01

    ..., after consideration of any timely comments submitted by the business, the EPA legal office makes a... is made by the business and approved by the EPA legal office. Except in extraordinary circumstances... determinations; matters to be considered. (1) If the EPA legal office finds that a business has failed to furnish...

  15. Biological profiling and dose-response modeling tools ...

    Science.gov (United States)

    Through its ToxCast project, the U.S. EPA has developed a battery of in vitro high throughput screening (HTS) assays designed to assess the potential toxicity of environmental chemicals. At present, over 1800 chemicals have been tested in up to 600 assays, yielding a large number of concentration-response data sets. Standard processing of these data sets involves finding a best fitting mathematical model and set of model parameters that specify this model. The model parameters include quantities such as the half-maximal activity concentration (or “AC50”) that have biological significance and can be used to inform the efficacy or potency of a given chemical with respect to a given assay. All of this data is processed and stored in an online-accessible database and website: http://actor.epa.gov/dashboard2. Results from these in vitro assays are used in a multitude of ways. New pathways and targets can be identified and incorporated into new or existing adverse outcome pathways (AOPs). Pharmacokinetic models such as those implemented EPA’s HTTK R package can be used to translate an in vitro concentration into an in vivo dose; i.e., one can predict the oral equivalent dose that might be expected to activate a specific biological pathway. Such predicted values can then be compared with estimated actual human exposures prioritize chemicals for further testing.Any quantitative examination should be accompanied by estimation of uncertainty. We are developing met

  16. Radiation doses and risks from internal emitters

    International Nuclear Information System (INIS)

    Harrison, John; Day, Philip

    2008-01-01

    This review updates material prepared for the UK Government Committee Examining Radiation Risks from Internal Emitters (CERRIE) and also refers to the new recommendations of the International Commission on Radiological Protection (ICRP) and other recent developments. Two conclusions from CERRIE were that ICRP should clarify and elaborate its advice on the use of its dose quantities, equivalent and effective dose, and that more attention should be paid to uncertainties in dose and risk estimates and their implications. The new ICRP recommendations provide explanations of the calculation and intended purpose of the protection quantities, but further advice on their use would be helpful. The new recommendations refer to the importance of understanding uncertainties in estimates of dose and risk, although methods for doing this are not suggested. Dose coefficients (Sv per Bq intake) for the inhalation or ingestion of radionuclides are published as reference values without uncertainty. The primary purpose of equivalent and effective dose is to enable the summation of doses from different radionuclides and from external sources for comparison with dose limits, constraints and reference levels that relate to stochastic risks of whole-body radiation exposure. Doses are calculated using defined biokinetic and dosimetric models, including reference anatomical data for the organs and tissues of the human body. Radiation weighting factors are used to adjust for the different effectiveness of different radiation types, per unit absorbed dose (Gy), in causing stochastic effects at low doses and dose rates. Tissue weighting factors are used to take account of the contribution of individual organs and tissues to overall detriment from cancer and hereditary effects, providing a simple set of rounded values chosen on the basis of age- and sex-averaged values of relative detriment. While the definition of absorbed dose has the scientific rigour required of a basic physical quantity

  17. New recommendations for dose equivalent

    International Nuclear Information System (INIS)

    Bengtsson, G.

    1985-01-01

    In its report 39, the International Commission on Radiation Units and Measurements (ICRU), has defined four new quantities for the determination of dose equivalents from external sources: the ambient dose equivalent, the directional dose equivalent, the individual dose equivalent, penetrating and the individual dose equivalent, superficial. The rationale behind these concepts and their practical application are discussed. Reference is made to numerical values of these quantities which will be the subject of a coming publication from the International Commission on Radiological Protection, ICRP. (Author)

  18. High dose rate (HDR) and low dose rate (LDR) interstitial irradiation (IRT) of the rat spinal cord

    International Nuclear Information System (INIS)

    Pop, Lucas A.M.; Plas, Mirjam van der; Skwarchuk, Mark W.; Hanssen, Alex E.J.; Kogel, Albert J. van der

    1997-01-01

    Purpose: To describe a newly developed technique to study radiation tolerance of rat spinal cord to continuous interstitial irradiation (IRT) at different dose rates. Material and methods: Two parallel catheters are inserted just laterally on each side of the vertebral bodies from the level of Th 10 to L 4 . These catheters are afterloaded with two 192 Ir wires of 4 cm length each (activity 1-2.3 mCi/cm) for the low dose rate (LDR) IRT or connected to the HDR micro-Selectron for the high dose rate (HDR) IRT. Spinal cord target volume is located at the level of Th 12 -L 2 . Due to the rapid dose fall-off around the implanted sources, a dose inhomogeneity across the spinal cord thickness is obtained in the dorso-ventral direction. Using the 100% reference dose (rate) at the ventral side of the spinal cord to prescribe the dose, experiments have been carried out to obtain complete dose response curves at average dose rates of 0.49, 0.96 and 120 Gy/h. Paralysis of the hind-legs after 5-6 months and histopathological examination of the spinal cord of each irradiated rat are used as experimental endpoints. Results: The histopathological damage seen after irradiation is clearly reflected the inhomogeneous dose distribution around the implanted catheters, with the damage predominantly located in the dorsal tract of the cord or dorsal roots. With each reduction in average dose rate, spinal cord radiation tolerance is significantly increased. When the dose is prescribed at the 100% reference dose rate, the ED 50 (induction of paresis in 50% of the animals) for the HDR-IRT is 17.3 Gy. If the average dose rate is reduced from 120 Gy/h to 0.96 or 0.49 Gy/h, a 2.9- or 4.7-fold increase in the ED 50 values to 50.3 Gy and 80.9 Gy is observed; for the dose prescribed at the 150% reference dose rate (dorsal side of cord) ED 50 values are 26.0, 75.5 and 121.4 Gy, respectively. Using different types of analysis and in dependence of the dose prescription and reference dose rate, the

  19. Work-In-Progress Peer Consult on EPA's Multimedia ...

    Science.gov (United States)

    This document is a compilation of responses from four external peer reviewers on EPA's "Multimedia Exposure Analysis to Inform a Public Health-Based Value for Lead in Drinking Water." It was delivered by Versar, Inc. under contract number EP-C-12-045 Task Order 91. Peer review report compiled, written and delivered by Versar, Inc to EPA.

  20. 40 CFR 600.109-08 - EPA driving cycles.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false EPA driving cycles. 600.109-08 Section... Model Year Automobiles-Test Procedures § 600.109-08 EPA driving cycles. (a) The FTP driving cycle is prescribed in § 86.115 of this chapter. (b) The highway fuel economy driving cycle is specified in this...

  1. Radiation Dose to Newborns in Neonatal Intensive Care Units

    International Nuclear Information System (INIS)

    Bahreyni Toossi, M. T.; Malekzadeh, M.

    2012-01-01

    With the increase of X-ray use for medical diagnostic purposes, knowing the given doses is necessary in patients for comparison with reference levels. The concept of reference doses or diagnostic reference levels has been developed as a practical aid in the optimization of patient protection in diagnostic radiology. To assess the radiation doses to neonates from diagnostic radiography (chest and abdomen). This study has been carried out in the neonatal intensive care unit of a province in Iran. Entrance surface dose was measured directly with thermoluminescent dosimeters. The population included 195 neonates admitted for a diagnostic radiography, in eight NICUs of different hospital types. The mean entrance surface dose for chest and abdomen examinations were 76.3 μGy and 61.5 μGy, respectively. Diagnostic reference levels for neonate in NICUs of the province were 88 μGy for chest and 98 μGy for abdomen examinations that were slightly higher than other studies. Risk of death due to radiation cancer incidence of abdomens examination was equal to 1.88 × 10 -6 for male and 4.43 × 10 -6 for female. For chest X-ray, it was equal to 2.54 × 10 -6 for male and 1.17 × 10 -5 for female patients. Diagnostic reference levels for neonates in our province were slightly higher than values reported by other studies such as European national diagnostic reference levels and the NRPB reference dose. The main reason was related to using a high mAs and a low kVp applied in most departments and also a low focus film distance. Probably lack of collimation also affected some exams in the NICUs.

  2. National Air Toxics Assessment - 2005, EPA Region 2 (EPA.AIR.NATA99_R2)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data layer is based on the model results of the 1999 National-Scale Assessment (N-SA), a part of the National Air Toxics Assessment (NATA), conducted by EPA's...

  3. National Air Toxics Assessment - 2002, EPA Region 2 (EPA.AIR.NATA99_R2)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data layer is based on the model results of the 1999 National-Scale Assessment (N-SA), a part of the National Air Toxics Assessment (NATA), conducted by EPA's...

  4. National Air Toxics Assessment - 1999, EPA Region 2 (EPA.AIR.NATA99_R2)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data layer is based on the model results of the 1999 National-Scale Assessment (N-SA), a part of the National Air Toxics Assessment (NATA), conducted by EPA's...

  5. Radiation dose monitoring in the clinical routine

    Energy Technology Data Exchange (ETDEWEB)

    Guberina, Nika [UK Essen (Germany). Radiology

    2017-04-15

    Here we describe the first clinical experiences regarding the use of an automated radiation dose management software to monitor the radiation dose of patients during routine examinations. Many software solutions for monitoring radiation dose have emerged in the last decade. The continuous progress in radiological techniques, new scan features, scanner generations and protocols are the primary challenge for radiation dose monitoring software systems. To simulate valid dose calculations, radiation dose monitoring systems have to follow current trends and stay constantly up-to-date. The dose management software is connected to all devices at our institute and conducts automatic data acquisition and radiation dose calculation. The system incorporates 18 virtual phantoms based on the Cristy phantom family, estimating doses in newborns to adults. Dose calculation relies on a Monte Carlo simulation engine. Our first practical experiences demonstrate that the software is capable of dose estimation in the clinical routine. Its implementation and use have some limitations that can be overcome. The software is promising and allows assessment of radiation doses, like organ and effective doses according to ICRP 60 and ICRP 103, patient radiation dose history and cumulative radiation doses. Furthermore, we are able to determine local diagnostic reference doses. The radiation dose monitoring software systems can facilitate networking between hospitals and radiological departments, thus refining radiation doses and implementing reference doses at substantially lower levels.

  6. EPA assessment of fallout in the United States from atmospheric nuclear testing on September 26 and November 17, 1976 by the People's Republic of China

    International Nuclear Information System (INIS)

    Strong, A.B.; Smith, J.M.; Johnson, R.H. Jr.

    1977-08-01

    Following the atmospheric nuclear weapons tests by the People's Republic of China on September 26 and November 17, 1976, the Environmental Radiation Ambient Monitoring System (ERAMS) network was fully activated and frequent samples of air particulates, precipitation, and pasteurized milk were collected for several weeks after each event. Population doses for the United States were calculated using the levels of radioactivity measured in these samples. Based on the calculated doses, health effects to the population of the United States were estimated. This report is a summary of EPA's assessment regarding the radiation doses and potential health effects which may be attributed to radioactive fallout from these nuclear weapons tests

  7. Reference dosimetry for CT in the UK

    International Nuclear Information System (INIS)

    Shrimpton, P.C.; Wall, B.F.

    2001-01-01

    Computed tomography is firmly established as a major source of population exposure from diagnostic x-ray examinations and thus a particular focus for radiological protection initiatives. The concept of reference doses is widely recognised as a useful and practical tool for promoting improvements in the optimisation of protection for patients undergoing radiological examinations. National diagnostic reference levels (DRLs) have already been successfully applied in the UK for some conventional x-ray examinations within a framework for advice on patient protection. This approach is being extended to include CT, utilising the robust methodology for reference dosimetry that has been developed by the European Commission (EC) for the particular conditions of exposure in CT. This is based on the dosimetric concepts of weighted computed tomography dose index (CTDI w ) per slice in serial scanning or per rotation in helical scanning, and dose-length product (DLP) per complete examination. Notwithstanding some initial values proposed by the EC, specific national DRLs for CT practice in the UK will be established on the basis of widescale national survey data. (author)

  8. The relation between the omega-3 index and arachidonic acid is bell shaped : Synergistic at low EPA plus DHA status and antagonistic at high EPA plus DHA status

    NARCIS (Netherlands)

    Luxwolda, Martine F.; Kuipers, Remko S.; Smit, Ella N.; Velzing-Aarts, Francien V.; Dijck-Brouwer, D. A. Janneke; Muskiet, Frits A. J.

    2011-01-01

    Introduction: The relation between docosahexaenoic (DHA) and eicosapentaenoic (EPA) vs. arachidonic acid (AA) seems characterized by both synergism and antagonism. Materials and methods: Investigate the relation between EPA + DHA and AA in populations with a wide range of EPA + DHA status and across

  9. Establishing diagnostic reference levels in digital radiology

    International Nuclear Information System (INIS)

    Bana, Remy Wilson

    2016-04-01

    Medical application of radiation has gained wider study since diagnostic radiology plays a very important role in modern medicine. The need of the service seems to increase since the invention of digital radiology as a new technology that promises greater accuracy while minimizing patient dose. However, it is not exempted in the harmonization of doses delivered to the patient undergoing same radiologic examination in different institutions either regional or nationwide. The objective of this project was to review the establishment of Diagnostic Reference Levels (DRLs) in digital radiology at National level with the aim to reduce patient dose while maintaining appropriate image quality. A general discussion on digital radiology has been presented focusing on the optimization of patient dose as well as dosimetric quantities used for the establishment of DRLs. Recommendations have been provided for Rwanda to initiate steps to establish National Diagnostic Reference Levels for common procedures in digital radiology. (au)

  10. EPA RE-Powering Screening Shapefile

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Center for Program Analysis (CPA) initiated the RE-Powering America’s...

  11. EPA's Green Roof Research

    Science.gov (United States)

    This is a presentation on the basics of green roof technology. The presentation highlights some of the recent ORD research projects on green roofs and provices insight for the end user as to the benefits for green roof technology. It provides links to currently available EPA re...

  12. Polybrominated Diphenyl Ethers in Human Milk and Serum from the U.S. EPA MAMA Study: Modeled Predictions of Infant Exposure and Considerations for Risk Assessment

    Science.gov (United States)

    Marchitti, Satori A.; Fenton, Suzanne E.; Mendola, Pauline; Kenneke, John F.; Hines, Erin P.

    2016-01-01

    Background: Serum concentrations of polybrominated diphenyl ethers (PBDEs) in U.S. women are believed to be among the world’s highest; however, little information exists on the partitioning of PBDEs between serum and breast milk and how this may affect infant exposure. Objectives: Paired milk and serum samples were measured for PBDE concentrations in 34 women who participated in the U.S. EPA MAMA Study. Computational models for predicting milk PBDE concentrations from serum were evaluated. Methods: Samples were analyzed using gas chromatography isotope-dilution high-resolution mass spectrometry. Observed milk PBDE concentrations were compared with model predictions, and models were applied to NHANES serum data to predict milk PBDE concentrations and infant intakes for the U.S. population. Results: Serum and milk samples had detectable concentrations of most PBDEs. BDE-47 was found in the highest concentrations (median serum: 18.6; milk: 31.5 ng/g lipid) and BDE-28 had the highest milk:serum partitioning ratio (2.1 ± 0.2). No evidence of depuration was found. Models demonstrated high reliability and, as of 2007–2008, predicted U.S. milk concentrations of BDE-47, BDE-99, and BDE-100 appear to be declining but BDE-153 may be rising. Predicted infant intakes (ng/kg/day) were below threshold reference doses (RfDs) for BDE-99 and BDE-153 but above the suggested RfD for BDE-47. Conclusions: Concentrations and partitioning ratios of PBDEs in milk and serum from women in the U.S. EPA MAMA Study are presented for the first time; modeled predictions of milk PBDE concentrations using serum concentrations appear to be a valid method for estimating PBDE exposure in U.S. infants. Citation: Marchitti SA, Fenton SE, Mendola P, Kenneke JF, Hines EP. 2017. Polybrominated diphenyl ethers in human milk and serum from the U.S. EPA MAMA Study: modeled predictions of infant exposure and considerations for risk assessment. Environ Health Perspect 125:706–713; http://dx.doi.org/10

  13. EPA's Radioactive Source Program

    International Nuclear Information System (INIS)

    Kopsick, D.

    2004-01-01

    The US EPA is the lead Federal agency for emergency responses to unknown radiological materials, not licensed, owned or operated by a Federal agency or an Agreement state (Federal Radiological Emergency Response Plan, 1996). The purpose of EPA's clean materials programme is to keep unwanted and unregulated radioactive material out of the public domain. This is achieved by finding and securing lost sources, maintaining control of existing sources and preventing future losses. The focus is on both, domestic and international fronts. The domestic program concentrates on securing lost sources, preventing future losses, alternative technologies like tagging of radioactive sources in commerce, pilot radioactive source roundup, training programs, scrap metal and metal processing facilities, the demolition industry, product stewardship and alternatives to radioactive devices (fewer radioactive source devices means fewer orphan sources). The international program consists of securing lost sources, preventing future losses, radiation monitoring of scrap metal at ports and the international scrap metal monitoring protocol

  14. Concept and use of reference animals and plants

    International Nuclear Information System (INIS)

    Pentreath, R.J.

    2005-01-01

    In order to manage the exposure of human beings to ionizing radiation, a device was needed that enabled exposures to be related to dose received, and hence for relating doses to effects. The result was an entity called Reference Man. It has therefore been argued that a similar approach could prove useful in attempting to manage radionuclides in the environment by having a framework with which to relate exposures to dose, and doses to effects, for other types of living things, by way of a set of entities called reference animals and plants. This set would necessarily be limited in scope, because it is clearly not possible even to try to encompass the vast array of living things that might need to be considered in various forms of environmental management practices. Nevertheless, a relatively small set could still be useful in drawing out many of the basic questions, and to serve as a reference against which other forms of animals and plants could be compared. This paper outlines some of the issues involved and makes some suggestions as to how they might be addressed. (author)

  15. Green Roof Research through EPA's Regional Applied Research Effort

    Science.gov (United States)

    ABSTRACT The U.S. Environmental Protection Agency’s (EPA) Regional Applied Research Effort (RARE) allows the Regions of the EPA to choose research projects to be performed in partnership with EPA’s Office of Research and Development (ORD). Over the last decade, several green roo...

  16. Enforcement Alert: Hazardous Waste Management Practices at Mineral Processing Facilities Under Scrutiny by U.S. EPA; EPA Clarifies 'Bevill Exclusion' Wastes and Establishes Disposal Standards

    Science.gov (United States)

    This is the enforcement alert for Hazardous Waste Management Practices at Mineral Processing Facilities Under Scrutiny by U.S. EPA; EPA Clarifies 'Bevill Exclusion' Wastes and Establishes Disposal Standards

  17. Epidemiological methods for assessing dose-response and dose-effect relationships

    DEFF Research Database (Denmark)

    Kjellström, Tord; Grandjean, Philippe

    2007-01-01

    Selected Molecular Mechanisms of Metal Toxicity and Carcinogenicity General Considerations of Dose-Effect and Dose-Response Relationships Interactions in Metal Toxicology Epidemiological Methods for Assessing Dose-Response and Dose-Effect Relationships Essential Metals: Assessing Risks from Deficiency......Description Handbook of the Toxicology of Metals is the standard reference work for physicians, toxicologists and engineers in the field of environmental and occupational health. This new edition is a comprehensive review of the effects on biological systems from metallic elements...... access to a broad range of basic toxicological data and also gives a general introduction to the toxicology of metallic compounds. Audience Toxicologists, physicians, and engineers in the fields of environmental and occupational health as well as libraries in these disciplines. Will also be a useful...

  18. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Ra; Min, Byung Il; Park, Kihyun; Yang, Byung Mo; Suh, Kyung Suk [Nuclear Environmental Safety Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    The International Commission on Radiological Protection (ICRP) recommendations and the Federal Guidance Report (FGR) published by the U.S. Environmental Protection Agency (EPA) have been widely applied worldwide in the fields of radiation protection and dose assessment. The dose conversion coefficients of the ICRP and FGR are widely used for assessing exposure doses. However, before the coefficients are used, the user must thoroughly understand the derivation process of the coefficients to ensure that they are used appropriately in the evaluation. The ICRP provides recommendations to regulatory and advisory agencies, mainly in the form of guidance on the fundamental principles on which appropriate radiological protection can be based. The FGR provides federal and state agencies with technical information to assist their implementation of radiation protection programs for the U.S. population. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR is reviewed in this study. A thorough understanding of their background is essential for the proper use of dose conversion coefficients. The FGR dose assessment system was strongly influenced by the ICRP and the U.S. National Council on Radiation Protection and Measurements (NCRP), and is hence consistent with those recommendations. Moreover, the ICRP and FGR both used the scientific data reported by Biological Effects of Ionizing Radiation (BEIR) and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) as their primary source of information. The difference between the ICRP and FGR lies in the fact that the ICRP utilized information regarding a population of diverse races, whereas the FGR utilized data on the American population, as its goal was to provide guidelines for radiological protection in the US. The contents of this study are expected to be utilized as basic research material in the areas of radiation protection and dose assessment.

  19. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR

    International Nuclear Information System (INIS)

    Kim, So Ra; Min, Byung Il; Park, Kihyun; Yang, Byung Mo; Suh, Kyung Suk

    2016-01-01

    The International Commission on Radiological Protection (ICRP) recommendations and the Federal Guidance Report (FGR) published by the U.S. Environmental Protection Agency (EPA) have been widely applied worldwide in the fields of radiation protection and dose assessment. The dose conversion coefficients of the ICRP and FGR are widely used for assessing exposure doses. However, before the coefficients are used, the user must thoroughly understand the derivation process of the coefficients to ensure that they are used appropriately in the evaluation. The ICRP provides recommendations to regulatory and advisory agencies, mainly in the form of guidance on the fundamental principles on which appropriate radiological protection can be based. The FGR provides federal and state agencies with technical information to assist their implementation of radiation protection programs for the U.S. population. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR is reviewed in this study. A thorough understanding of their background is essential for the proper use of dose conversion coefficients. The FGR dose assessment system was strongly influenced by the ICRP and the U.S. National Council on Radiation Protection and Measurements (NCRP), and is hence consistent with those recommendations. Moreover, the ICRP and FGR both used the scientific data reported by Biological Effects of Ionizing Radiation (BEIR) and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) as their primary source of information. The difference between the ICRP and FGR lies in the fact that the ICRP utilized information regarding a population of diverse races, whereas the FGR utilized data on the American population, as its goal was to provide guidelines for radiological protection in the US. The contents of this study are expected to be utilized as basic research material in the areas of radiation protection and dose assessment

  20. Hispanos en la EPA: Rafael DeLeón

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  1. US EPA's SPECIATE 4.4 Database: Development and Uses

    Science.gov (United States)

    SPECIATE is the U.S. Environmental Protection Agency’s (EPA) repository of volatile organic gas and particulate matter (PM) speciation profiles of air pollution sources. EPA released SPECIATE 4.4 in early 2014 and, in total, the SPECIATE 4.4 database includes 5,728 PM, volatile o...

  2. 40 CFR 74.10 - Roles-EPA and permitting authority.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Roles-EPA and permitting authority. 74... (CONTINUED) SULFUR DIOXIDE OPT-INS Permitting Procedures § 74.10 Roles—EPA and permitting authority. (a... end-of-year compliance, determining reduced utilization, approving thermal energy transfer and...

  3. EPA Nonregulatory Nonroad Duty Cycles

    Science.gov (United States)

    EPA nonregulatory, nonroad duty cycles for equipment such as agricultural tractors, backhoe loaders,crawlers tractors, excavators, arc welding skid steer loaders, and wheel loaders. Also,test procedures, laboratory methods, and emissions for this equipmen

  4. ASSESSING CHILDREN'S EXPOSURES TO PESTICIDES: AN IMPORTANT APPLICATION OF THE STOCHASTIC HUMAN EXPOSURE AND DOSE SIMULATION MODEL (SHEDS)

    Science.gov (United States)

    Accurately quantifying human exposures and doses of various populations to environmental pollutants is critical for the Agency to assess and manage human health risks. For example, the Food Quality Protection Act of 1996 (FQPA) requires EPA to consider aggregate human exposure ...

  5. Eye lens dosimetry in interventional cardiology: Results of staff dose measurements and link to patient dose levels

    International Nuclear Information System (INIS)

    Antic, V.; Ciraj-Bjelac, O.; Rehani, M.; Aleksandric, S.; Arandjic, D.; Ostojic, M.

    2013-01-01

    Workers involved in interventional cardiology procedures receive high eye lens dose if protection is not used. Currently, there is no suitable method for routine use for the measurement of eye dose. Since most angiography machines are equipped with suitable patient dosemeters, deriving factors linking staff eye doses to the patient doses can be helpful. In this study the patient kerma-area product, cumulative dose at an interventional reference point and eye dose in terms of Hp(3) of the cardiologists, nurses and radiographers for interventional cardiology procedures have been measured. Correlations between the patient dose and the staff eye dose were obtained. The mean eye dose was 121 mSv for the first operator, 33 mSv for the second operator/nurse and 12 mSv for radiographer. Normalised eye lens doses per unit kerma-area product were 0.94 mSv Gy -1 cm -2 for the first operator, 0.33 mSv Gy -1 cm -2 for the second operator/nurse and 0.16 mSv Gy -1 cm -2 for radiographers. Statistical analysis indicated that there is a weak but significant (p < 0.01) correlation between the eye dose and the kerma-area product for all three staff categories. These values are based on a local practice and may provide useful reference for other studies for validation and for wider utilisation in assessing the eye dose using patient dose values. (authors)

  6. The Basic Principles in Assessment and Selection of Reference Doses: Considerations in Nuclear Medicine (invited paper)

    International Nuclear Information System (INIS)

    Mattsson, S.; Jacobsson, L.; Vestergren, E.

    1998-01-01

    The possible ways to optimise the relation between diagnostic information and patient absorbed dose differ between nuclear medicine and X ray imaging. In nuclear medicine, very little has been done to find an optimal dosage of radiopharmaceuticals. Current nuclear medicine methods are discussed in the light of the recent ICRP Publications and the new EU Patient Directive. The paper also discusses how reference levels for administered activity may be derived from patient studies. In order to eliminate the most inappropriate choices (too low or too high activities), knowledge of the current statistical distribution of administered activities may be helpful. Different methods to estimate the amount of activity that should be administered to children of various body sizes to guarantee the same image quality as for adults are also discussed. Examples of current activity levels for common nuclear medicine procedures, indicating the state of the practice, are given. (author)

  7. IRIS Assessment Plan for Uranium (Scoping and Problem Formulation Materials)

    Science.gov (United States)

    In January 2018, EPA released the IRIS Assessment Plan for Uranium (Oral Reference Dose) (Scoping and Problem Formulation Materials). An IRIS Assessment Plan (IAP) communicates to the public the plan for assessing each individual chemical and includes summary informatio...

  8. EFFECT OF DOSE ON THE EXCRETION AND METABOLISM OF MONOMETHYLARSONIC ACID IN THE MOUSE

    Science.gov (United States)

    EFFECT OF DOSE ON THE EXCRETION AND METABOLISM OF MONOMETHYLARSONIC ACID IN THE MOUSEM F Hughes1, V Devesa2, B C Edwards1, C T Mitchell1, E M Kenyon1, and D J Thomas1. 1US EPA, ORD, NHEERL, ETD, Research Triangle Park, NC; 2UNC-CH, CEMALB, Chapel Hill, NCMonomethylar...

  9. Practical experience of monitoring patient dose

    Energy Technology Data Exchange (ETDEWEB)

    McDonnell, C.; Shrimpton, P. (National Radiological Protection Board, Chilton (United Kingdom)); O' Mahoney, M. (National Radiological Protection Board, Leeds (United Kingdom)); Foster, J. (Nuffield Hospitals, Surbiton (United Kingdom))

    1994-05-01

    NRPB recommends the use of reference dose levels for diagnostic medical exposures as an aid to patient dose reduction, but is this approach effective This article describes the broadly encouraging experiences of one large group of hospitals in carrying out measurements of entrance surface dose on patients undergoing some common types of x-ray examination. (author).

  10. A new method to assess the gonadal doses in women during radiation treatment

    International Nuclear Information System (INIS)

    Agrawal, M.S.; Pant, G.C.

    1977-01-01

    The relative inaccessibility of the ovaries renders direct measurement of the gonadal doses difficult. A relatively simple method is described to tackle this problem - using the upper margin of the public symphysis as a reference point. Measurement of Radiation doses were done in a Masonite human phantom using T.L.D. and a Co-60 teletherapy unit. The accompanying figures document the observations made. The distance between the lower edge of the treatment port and the reference point is denoted by 'd'. First figure relates observed ratios of the radiation doses at the ovary and the reference point to 'd' for various port sizes and the second figure shows the relationship between the area of the port and the dose ratio (ovary: reference-point) for various values of 'd'. The advantage of this documentation is that it serves as a 'Ready Reckoner' to assess the ovarian doses under different treatment situations-once the doses at the reference point is measured

  11. Supplementation of docosahexaenoic acid (DHA) / Eicosapentaenoic acid (EPA) in a ratio of 1/1.3 during the last trimester of pregnancy results in EPA accumulation in cord blood.

    Science.gov (United States)

    Büyükuslu, Nihal; Ovalı, Sema; Altuntaş, Şükriye Leyla; Batırel, Saime; Yiğit, Pakize; Garipağaoğlu, Muazzez

    2017-10-01

    Omega-3 fatty acids (n-3 FA), specifically DHA, are associated with fetal growth and development. We aimed to determine the levels of DHA and EPA in cord serum after n-3 FA supplementation during the last trimester of pregnancy. Among 55 women, 23 were administered daily one capsule of n-3 FA supplement, involving DHA/EPA in a ratio of 1/1.3. Twenty nine women were enrolled as control group. Blood samples were collected at 22-24 weeks of gestation and at delivery. Fatty acids were analyzed with the method of GC-MS. Cord DHA level increased and EPA level decreased in both groups between the days of 22-24 and delivery. However, decrease in cord EPA level was significant in control group (p 0.05). Supplementation of DHA/EPA in a ratio of 1/1.3 during the last trimester of pregnancy caused higher cord EPA level compared to control group indicating an accumulation in umbilical cord. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Computed Tomography (CT) radiation dose in children: A survey to propose regional diagnostic reference levels in Greater Accra-Ghana

    International Nuclear Information System (INIS)

    Addo, Patience

    2016-07-01

    The aim of this work was to assess the doses delivered to paediatric patients during computed tomography (CT) examinations of the head, chest and abdomen, and establishing regional diagnostic reference levels (RDRLs) for four age groups. The patient data, technique parameters and dose descriptors collected include: age, sex, tube voltage, tube current, rotation time, slice thickness, scan length, volume CT dose index (CTDI_v_o_l) and dose length product (DLP). Currently, paediatric CT examinations account for 11% of radiation exposure. For the paediatric age groups; < 1 year, (1-5 years), (6-10 years) and (11-15 years), the proposed RDRLs for head in terms of CTDI_v_o_l are (28, 38, 48 and 86 mGy) and in terms of DLP; (395, 487, 601, 1614 mGy cm) respectively. For Chest examinations, proposed RDRLs in terms of CTDI_v_o_l are (1 and 5 mGy) and in terms of DLP; (18 and 110 mGy cm) for age groups; < 1 year and (1-5 years) respectively. For Abdomino-pelvic examinations, proposed RDRLs in terms of CTDI_v_o_l are (3, 3 and 10 mGy) and in terms of DLP; (71, 120 and 494 mGy cm) for age groups; < 1 year, (1-5 years) and (6-10 years) respectively. For abdomen examinations, proposed RDRLs in terms of CTDI_v_o_l are (3, 5 and 5 mGy) and in terms of DLP; (83, 124 and 233 mGy cm) for age groups; < 1 year, (1-5 years) and (11-15 years) respectively. RDRLs have been proposed for CTDI_v_o_l and DLP for head, chest, abdomen and Abdomino-pelvic paediatric CT examinations in this study. An optimisation is required for 11-15 years age group for the DLP values which was higher than their corresponding international DRLs. For an effective optimization of patient protection a trade-off between image quality and patients doses studies should be investigated. (au)

  13. 40 CFR 147.1703 - EPA-administered program-Indian lands.

    Science.gov (United States)

    2010-07-01

    ... Carolina § 147.1703 EPA-administered program—Indian lands. (a) Contents. The UIC program for all classes of wells on Indian lands in the State of North Carolina is administered by EPA. This program consists of... these requirements. (b) Effective date. The effective date of the UIC program for Indian lands in North...

  14. TLD postal dose quality audit service for Co-60 beams in reference conditions in Cuba

    International Nuclear Information System (INIS)

    Gutierrez Lores, S.; Walwyn Salas, G.; Alonso Villanueva, G.

    2008-01-01

    This report presents the methodology and experience of the Cuban's Secondary Standard Dosimetry Laboratory for the implementation of postal dose quality audits service for Co-60 beams in reference conditions, using TLDs. Under coordinated research project (Contract 10794) were bought (TLD -100) Tl rods type JR 1152F made in China, with dimensions of 6 mm x 1 mm x 1 mm. All of these rods were identified individually with a consecutive number made over one of its sides, using a fine tip of graphite. The method used to determinate the individual sensibility of the TL detectors was: irradiating a group of them, with the same history of irradiation and readout (100 rods approximately), four serial times in the same geometrical conditions, to read them out and to attribute to each of them a sensitivity factor. This sensitivity factor is equal to average for the 4 cycle of irradiation and readout of the quote between the TL readout from dosimeter i and the mean of all values for each cycle. The TLD signal was read using HARSHAW 2000C/B reader. The results obtained in the external verification of the accuracy of the dose determination by the TLD system were performed in cooperation with IAEA Dosimetry Laboratory at Seibersdorf in different years are shown, the results obtained of the quality audits carried out to the different services of radiotherapy of the country are analysed also. The quality audits are an useful tool for the improvement of the accuracy in the dosimetry of clinical beams of radiotherapy with Co-60, contributing this way to the improvement of the life quality to cancer patients of the Cuban system of health. (author)

  15. Standardized dose factors for dose calculations - 1982 SRP reactor safety analysis report tritium, iodine, and noble gases

    International Nuclear Information System (INIS)

    Pillinger, W.L.; Marter, W.L.

    1982-01-01

    Standardized dose constants are recommended for calculation of offsite doses in the 1982 SRP Reactor Safety Analysis Report (SAR). Dose constants are proposed for inhalation of tritium and radioiodines and for submersion in a semi-infinite cloud of radioiodines and noble gases. The proposed constants, based on ICRP2 methodology for internal dose and methodology recommended by the US Nuclear Regulatory Commission for external dose, are compatible with dose calculational methods used at the Savannah River Plant and Savannah River Laboratory for normal releases of radioactivity. 8 references

  16. Study on the setting of Reference Chinese man

    International Nuclear Information System (INIS)

    Wang Jixian; Chen Rusong

    1998-01-01

    The procedures for internal and external dose estimation, the calculation of authorized limits and derived reference levels, and the development of phantoms in the field of radiation protection are based on values for the ICRP Reference Man. Many differences exist between Asians, Europeans and North Americans with respect to race, customs and the pattern of food consumption. The neglect of these differences in the parameters used may lead to errors in dose assessment and health effect prognosis. research described in this paper was conducted to obtain reference values for the Chinese population or other Asian countries which might have major demographic contribution of Chinese. Based on the agreements reached in the Project Formulation Meeting ''Compilation of Anatomical, Physiological and Metabolic Characteristics for a Reference Asian Man'', the measurement of physique, organ mass and the food consumption were given the first priority for the first phase of the project. (author)

  17. EPA Region 1 - Map Layers for Valley ID Tool (Hosted Feature Service)

    Science.gov (United States)

    The Valley Service Feature Layer hosts spatial data for EPA Region 1's Valley Identification Tool. These layers contain attribute information added by EPA R1 GIS Center to help identify populated valleys:- Fac_2011NEI: Pollution sources selected from the National Emissions Inventory (EPA, 2011).- NE_Towns_PopValleys: New England Town polygons (courtesy USGS), with Population in Valleys and Population Density in Valleys calculated by EPA R1 GIS, from 2010 US Census blocks. - VT_E911: Vermont residences (courtesy VT Center for Geographic Information E-911).

  18. Physical characteristics of the Japanese in relation to reference man

    International Nuclear Information System (INIS)

    Tanaka, G.-i.; Kawamura, H.; Nomura, E.

    1980-01-01

    Quantitative description of physical and other characteristics of the human body provides basic data for the estimation of radiation risk and the establishment of dose equivalent in line with the International Commission on Radiological Protection recommendations. ICRP Reference Man is based essentially on data reported on populations in rather limited areas in the world although Committee 2 of ICRP concedes that ''it is neither feasible nor necessary to specify Reference Man as representative of a well-defined population group''. ICRP Reference Man is not necessarily based on the most recent available data. In order to be more realistic and quantitative in dose equivalent estimation in Japan, it is necessary to consider populations which are largely different from those of European and North American countries in physical dimensions and other aspects. Therefore, standard or reference values of mass and size of organs, body and organ content and metabolic parameters of some elements have been studied. These are compared with the values of ICRP Reference Man authorized up to now, with the intention of establishing ''Reference Japanese Man'' and contributing to the improvement of models of man used in radiation protection. Dose equivalent commitment and annual limit of intake have been calculated using the obtained data for the general population in Japan,for some nuclides. (H.K.)

  19. 40 CFR 13.22 - Salary offset when EPA is the creditor agency.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Salary offset when EPA is the creditor... COLLECTION STANDARDS Administrative Offset § 13.22 Salary offset when EPA is the creditor agency. (a... through salary offset, EPA will first provide the employee with the opportunity to pay in full the amount...

  20. NaKnowBaseTM: The EPA Nanomaterials Research ...

    Science.gov (United States)

    The ability to predict the environmental and health implications of engineered nanomaterials is an important research priority due to the exponential rate at which nanotechnology is being incorporated into consumer, industrial and biomedical applications. To address this need and develop predictive capability, we have created the NaKnowbaseTM, which provides a platform for the curation and dissemination of EPA nanomaterials data to support functional assay development, hazard risk models and informatic analyses. To date, we have combined relevant physicochemical parameters from other organizations (e.g., OECD, NIST), with those requested for nanomaterial data submitted to EPA under the Toxic Substances Control Act (TSCA). Physiochemical characterization data were collated from >400 unique nanomaterials including metals, metal oxides, carbon-based and hybrid materials evaluated or synthesized by EPA researchers. We constructed parameter requirements and table structures for encoding research metadata, including experimental factors and measured response variables. As a proof of concept, we illustrate how SQL-based queries facilitate a range of interrogations including, for example, relationships between nanoparticle characteristics and environmental or toxicological endpoints. The views expressed in this poster are those of the authors and may not reflect U.S. EPA policy. The purpose of this submission for clearance is an abstract for submission to a scientific

  1. Survey of EPA facilities for solar thermal energy applications

    Science.gov (United States)

    Nelson, E. V.; Overly, P. T.; Bell, D. M.

    1980-01-01

    A study was done to assess the feasibility of applying solar thermal energy systems to EPA facilities. A survey was conducted to determine those EPA facilities where solar energy could best be used. These systems were optimized for each specific application and the system/facility combinations were ranked on the basis of greatest cost effectiveness.

  2. Abandoned Uranium Mines (AUM) Site Screening Map Service, 2016, US EPA Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — As described in detail in the Five-Year Report, US EPA completed on-the-ground screening of 521 abandoned uranium mine areas. US EPA and the Navajo EPA are using the...

  3. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA); Scientific Opinion on the substantiation of health claims related to docosahexaenoic acid (DHA), eicosapentaenoic acid (EPA) and gamma-linolenic acid (GLA) and contribution to normal cognitive function (ID 532) and maintenance

    DEFF Research Database (Denmark)

    Tetens, Inge

    claims in relation to docosahexaenoic acid (DHA), eicosapentaenoic acid (EPA) and gamma-linolenic acid (GLA) and contribution to normal cognitive function and maintenance of normal bone. The scientific substantiation is based on the information provided by the Member States in the consolidated list...... and fish oil”. From the references provided, the Panel assumes that the food constituents that are the subject of the claims are the n-6 fatty acid gamma-linolenic acid (GLA) in evening primrose oil and the n-3 long-chain polyunsaturated fatty acids docosahexaenoic acid (DHA) and eicosapentaenoic acid (EPA...... of Article 13 health claims and references that EFSA has received from Member States or directly from stakeholders. The food constituents that are the subjects of the health claims are “omega-3 and omega-6 fatty acids (GLA)”, “gamma-linolenic acid + eicosapentaenoic acid (GLA+EPA)”, and “evening primrose oil...

  4. Quality assurance in CT: implementation of the updated national diagnostic reference levels using an automated CT dose monitoring system.

    Science.gov (United States)

    Appel, E; Kröpil, P; Bethge, O T; Aissa, J; Thomas, C; Antoch, G; Boos, J

    2018-03-20

    To evaluate the implementation of the updated computed tomography (CT) diagnostic reference levels (DRLs) from the German Federal Office for Radiation Protection into clinical routine using an automatic CT dose monitoring system. CT radiation exposure was analysed before and after implementing the updated national DRLs into routine clinical work in 2016. After the implementation process, institutional CT protocols were mapped to the anatomical regions for which DRLs were provided. Systematically, protocols that exceeded the thresholds were optimised and analysed in detail. The CT radiation output parameters analysed were volumetric CT dose index (CTDIvol) and dose-length product (DLP). Three radiologists evaluated subjective image quality using a three-point Likert scale. The study included 94,258 CT series (from 27,103 CT examinations) in adult patients performed in 2016. When averaged over all body regions with available DRL, institutional CTDIvol/DLP values were always below the DRLs (65.2±32.9%/67.3±41.5% initially; 59.4±32%/60.5±39.9% after optimisation). Values exceeding the national DRLs were found for pelvis (n=268; CTDIvol 107.7±65.7%/DLP 106.3±79.3%), lumbar spine (n=91; 160.8±74.7%/175.2±104.1%), and facial bones (n=527; 108±39%/152.7±75.7%). After optimisation, CTDIvol and DLP were 87.9±73%/87.8±80.8% for the pelvis, 67.8±33.2%/74.5±50.6% for the lumbar spine and 95.1±45.8%/133.3±74.6% for the viscerocranium. An automatic CT dose monitoring system enabled not only comprehensive monitoring of a DRL implementation process but can also help to optimise radiation exposure. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  5. SU-E-P-10: Establishment of Local Diagnostic Reference Levels of Routine Exam in Computed Tomography

    International Nuclear Information System (INIS)

    Yeh, M; Wang, Y; Weng, H

    2015-01-01

    Introduction National diagnostic reference levels (NDRLs) can be used as a reference dose of radiological examination can provide radiation dose as the basis of patient dose optimization. Local diagnostic reference levels (LDRLs) by periodically view and check doses, more efficiency to improve the way of examination. Therefore, the important first step is establishing a diagnostic reference level. Computed Tomography in Taiwan had been built up the radiation dose limit value,in addition, many studies report shows that CT scan contributed most of the radiation dose in different medical. Therefore, this study was mainly to let everyone understand DRL’s international status. For computed tomography in our hospital to establish diagnostic reference levels. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). Each exam each different body part, we collect 10 patients at least. Carried out the routine examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. Results: The majority of patients (75%) were between 60–70 Kg of body weight. There are 25 examinations in this study. Table 1 shows the LDRL of each CT routine examination. Conclusions: Therefore, this study would like to let everyone know DRL’s international status, but also establishment of computed tomography of the local reference levels for our hospital, and providing radiation reference, as a basis for optimizing patient dose

  6. SU-E-P-10: Establishment of Local Diagnostic Reference Levels of Routine Exam in Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, M; Wang, Y; Weng, H [Chiayi Chang Gung Memorial Hospital of The C.G.M.F, Puzi City, Chiayi County, Taiwan (China)

    2015-06-15

    Introduction National diagnostic reference levels (NDRLs) can be used as a reference dose of radiological examination can provide radiation dose as the basis of patient dose optimization. Local diagnostic reference levels (LDRLs) by periodically view and check doses, more efficiency to improve the way of examination. Therefore, the important first step is establishing a diagnostic reference level. Computed Tomography in Taiwan had been built up the radiation dose limit value,in addition, many studies report shows that CT scan contributed most of the radiation dose in different medical. Therefore, this study was mainly to let everyone understand DRL’s international status. For computed tomography in our hospital to establish diagnostic reference levels. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). Each exam each different body part, we collect 10 patients at least. Carried out the routine examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. Results: The majority of patients (75%) were between 60–70 Kg of body weight. There are 25 examinations in this study. Table 1 shows the LDRL of each CT routine examination. Conclusions: Therefore, this study would like to let everyone know DRL’s international status, but also establishment of computed tomography of the local reference levels for our hospital, and providing radiation reference, as a basis for optimizing patient dose.

  7. Agriculture: About EPA's National Agriculture Center

    Science.gov (United States)

    EPA's National Agriculture Center (Ag Center), with the support of the United States Department of Agriculture, serves growers, livestock producers, other agribusinesses, and agricultural information/education providers.

  8. GET SMART: EPA'S SMARTE INITIATIVE

    Science.gov (United States)

    The EPA's Office of Research and Development with the assistance of the U.S.-German Bilateral Working Group and the Interstate Technology Regulatory Council (ITRC), is developing Site-specific Management Approaches and Revitalization Tools (SMART) that will help stakeholders over...

  9. EPA Principles for Greener Cleanups

    Science.gov (United States)

    A goal of the U.S. Environmental Protection Agency (EPA) Office and Land and Emergency Management (OLEM) and its many partners is to preserve and restore land by promoting and using protective waste management practices and by assessing and cleaning..

  10. USDA-EPA Collaborative Ammonia Research

    Science.gov (United States)

    In 2014, a work group was formed between USDA and EPA to facilitate information exchange on ammonia emissions from agriculture, air quality impacts and emission mitigation options and to identify opportunities for collaboration. This document provides background on the work grou...

  11. US EPA Digital Science: An Evolution

    Science.gov (United States)

    Ziegler, C. R.; Burch, K.; Laniak, G.; Vega, A.; Harten, P.; Kremer, J.; Brookes, A.; Yuen, A.; Subramanian, B.

    2015-12-01

    The United States Environmental Protection Agency's (US EPA) digital science "enterprise" plays a critical role in US EPA's efforts to achieve its mission to protect human health and the environment. This enterprise is an evolving cross-disciplinary research and development construct, with social and institutional dimensions. It has an active development community and produces a portfolio of digital science products including decision support tools, data repositories, Web interfaces, and more. Earth sciences and sustainable development organizations from around the world - including US government agencies - have achieved various levels of success in taking advantage of the rapidly-evolving digital age. Efficiency, transparency and ability to innovate are tied to an organization's digital maturity and related social characteristics. Concepts like participatory web, data and software interoperability, global technology transfer, ontological harmonization, big data, scaling, re-use and open science are no longer "new and emerging." They have emerged and - in some cases - are tied to US government directives. We assess maturity, describe future scenarios, discuss new initiatives and outline steps for better leveraging the information age to more effectively and efficiently achieve US EPA's mission. The views expressed herein are those of the authors and do not necessarily reflect the views or policies of the organizations for which they work and/or represent.

  12. Dose assessment in pediatric computerized tomography; Avaliacao de doses em tomografia computadorizada pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Vilarinho, Luisa Maria Auredine Lima

    2004-07-01

    The objective of this work was the evaluation of radiation doses in paediatric computed tomography scans, considering the high doses usually involved and the absence of any previous evaluation in Brazil. Dose values were determined for skull and abdomen examinations, for different age ranges, by using the radiographic techniques routinely used in the clinical centers investigated. Measurements were done using pencil shape ionization chambers inserted in polymethylmethacrylate (PMMA) phantoms. These were compact phantoms of different diameters were specially designed and constructed for this work, which simulate different age ranges. Comparison of results with published values showed that doses were lower than the diagnostic reference levels established to adults exams by the European Commission. Nevertheless, doses in paediatric phantoms were higher than those obtained in adult phantoms. The paediatric dose values obtained in Hospitals A and B were lower than the reference level (DRL) adopted by SHIMPTON for different age ranges. In the range 0 - 0.5 year (neonatal), the values of DLP in Hospital B were 94 por cent superior to the DRL For the 10 years old children the values of CTDI{sub w} obtained were inferior in 89 por cent for skull and 83 por cent for abdomen examinations, compared to the values published by SHRIMPTON and WALL. Our measured CTDI{sub w} values were inferior to the values presented for SHRIMPTON and HUDA, for all the age ranges and types of examinations. It was observed that the normalized dose descriptors values in children in the neonatal range were always superior to the values of doses for the adult patient. In abdomen examinations, the difference was approximately 90% for the effective dose (E) and of 57%.for CTDI{sub w} . (author)

  13. Method of evaluation of diagnostics reference levels in computerized tomography

    International Nuclear Information System (INIS)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  14. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA); Scientific Opinion related to the Tolerable Upper Intake Level of eicosapentaenoic acid (EPA), docosahexaenoic acid (DHA) and docosapentaenoic acid (DPA)

    DEFF Research Database (Denmark)

    Tetens, Inge

    Following a request from the European Commission, the Panel on Dietetic Products, Nutrition and Allergies was asked to deliver a scientific opinion on the Tolerable Upper Intake Level (UL) of the n-3 LCPUFAs eicosapentaenoic acid (EPA), docosahexaenoic acid (DHA) and docosapentaenoic acid (DPA......). Available data are insufficient to establish a UL for n-3 LCPUFA (individually or combined) for any population group. At observed intake levels, consumption of n-3 LCPUFA has not been associated with adverse effects in healthy children or adults. Long-term supplemental intakes of EPA and DHA combined up...... to about 5 g/day do not appear to increase the risk of spontaneous bleeding episodes or bleeding complications, or affect glucose homeostasis immune function or lipid peroxidation, provided the oxidative stability of the n-3 LCPUFAs is guaranteed. Supplemental intakes of EPA and DHA combined at doses of 2...

  15. Dose specification and normal tissue reference points in the treatment of cancer cervix

    International Nuclear Information System (INIS)

    Ray, D.K.; Kumar, P.; Misra, D.K.; Das, R.; Kumar, A.; Maji, T.; Chaudhuri, P.; Sinha, T.P.

    2007-01-01

    Carcinoma of uterine cervix is one of the most common diseases among the women in India where radiotherapy is the mainstay of treatment. Most common practice of dose prescription point is the Manchester Point A. American Brachytherapy Society (ABS) recommends a point H equivalent to that used in the classical Manchester system. Many centre practices Madison point M as dose specification point which is 20 mm cephaled along the tandem from a line joining the mid dwell positions in the ovoids/ring and 20 mm lateral to the tandem. In the present study has compared the dose prescription points between Manchester Point A and Madison Point M for ring applicators and their implication in the assessment of rectal and bladder doses in patients of Carcinoma of uterine cervix

  16. In defence of collective dose

    International Nuclear Information System (INIS)

    Fairlie, I.; Sumner, D.

    2000-01-01

    Recent proposals for a new scheme of radiation protection leave little room for collective dose estimations. This article discusses the history and present use of collective doses for occupational, ALARA, EIS and other purposes with reference to practical industry papers and government reports. The linear no-threshold (LNT) hypothesis suggests that collective doses which consist of very small doses added together should be used. Moral and ethical questions are discussed, particularly the emphasis on individual doses to the exclusion of societal risks, uncertainty over effects into the distant future and hesitation over calculating collective detriments. It is concluded that for moral, practical and legal reasons, collective dose is a valid parameter which should continue to be used. (author)

  17. Methodology for setting the reference levels in the measurements of the dose rate absorbed in air due to the environmental gamma radiation

    International Nuclear Information System (INIS)

    Dominguez Ley, Orlando; Capote Ferrera, Eduardo; Caveda Ramos, Celia; Alonso Abad, Dolores

    2008-01-01

    Full text: The methodology for setting the reference levels of the measurements of the gamma dose rate absorbed in the air is described. The registration level was obtained using statistical methods. To set the alarm levels, it was necessary to begin with certain affectation level, which activates the investigation operation mode when being reached. It is was necessary to transform this affectation level into values of the indicators selected to set the appearance of an alarm in the network, allowing its direct comparison and at the same time a bigger operability of this one. The affectation level was assumed as an effective dose of 1 mSv/y, which is the international dose limit for public. The conversion factor obtained in a practical way as a consequence of the Chernobyl accident was assumed, converting the value of annual effective dose into values of effective dose rate in air. These factors are the most important in our work, since the main task of the National Network of Environmental Radiological Surveillance of the Republic of Cuba is detecting accidents with a situations regional affectation, and this accident is precisely an example of pollution at this scale. The alarm level setting was based on the results obtained in the first year of the Chernobyl accident. For this purpose, some transformations were achieved. In the final results, a correction factor was introduced depending on the year season the measurement was made. It was taken into account the influence of different meteorological events on the measurement of this indicator. (author)

  18. EPA RE-Powering Mapper Region 7

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  19. EPA RE-Powering Mapper Large Scale

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  20. EPA RE-Powering Mapper Region 6

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  1. EPA RE-Powering Mapper Region 8

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  2. EPA RE-Powering Mapper Region 5

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  3. EPA RE-Powering Mapper Region 3

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  4. EPA RE-Powering Mapper Feasibility Studies

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  5. EPA RE-Powering Mapper Completed Installations

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  6. EPA RE-Powering Mapper Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  7. EPA RE-Powering Mapper Region 10

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  8. EPA RE-Powering Mapper Region 4

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  9. EPA RE-Powering Mapper Utility Scale

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  10. EPA RE-Powering Mapper Region 2

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  11. EPA RE-Powering Mapper Region 1

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  12. EPA Facility Registry Service (FRS): RCRA

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of hazardous waste...

  13. EPA-Registered Repellents for Mosquitoes Transmitting Emerging Viral Disease.

    Science.gov (United States)

    Patel, Radha V; Shaeer, Kristy M; Patel, Pooja; Garmaza, Aleksey; Wiangkham, Kornwalee; Franks, Rachel B; Pane, Olivia; Carris, Nicholas W

    2016-12-01

    In many parts of the United States, mosquitoes were previously nuisance pests. However, they now represent a potential threat in the spread of viral diseases. The Aedes aegypti, Aedes albopictus, and Culex species mosquitoes are endemic to the United States and together may transmit a variety of viral diseases of growing concern, including West Nile virus, chikungunya, dengue fever, and Zika virus. The Centers for Disease Control and Prevention and the Environmental Protection Agency (EPA) recommend N,N-diethyl-meta-toluamide (DEET) as a first-line mosquito repellent, but for patients refusing to use DEET or other conventional repellents, guidance is limited to any EPA-registered product. Therefore, we conducted a systematic review of the literature to identify which EPA-registered personal mosquito repellent provides the best protection from A. aegypti, A. albopictus, and Culex spp. mosquitoes. We abstracted data from 62 published reports of EPA-registered mosquito repellents. The conventional repellent picaridin has the strongest data to support its use as a second-line agent, while IR3535 and oil of lemon eucalyptus are reasonably effective natural products. Citronella, catnip, and 2-undecanone offer limited protection or have limited data. These results can be used by pharmacists and other health care professionals to advise patients on the selection of an EPA-registered mosquito repellent. Regardless of the repellent chosen, it is vital for patients to follow all instructions/precautions in the product labeling to ensure safe and effective use. © 2016 Pharmacotherapy Publications, Inc.

  14. Potential radionuclide emissions from stacks on the Hanford Site. Part 1: Dose assessment

    International Nuclear Information System (INIS)

    Davis, W.E.; Barnett, J.M.

    1994-06-01

    On February 3, 1993, the US Department of Energy, Richland Operations Office (RL) received a Compliance Order and Information Request from the Director of the Air and Toxics Division of the US Environmental Protection Agency (EPA), Region 10. The Compliance Plan specified that a dose assessment would be performed for 84 Westinghouse Hanford Company (WHC) stacks registered with the Washington State Department of Health (WAC 246-247) on the Hanford Site. Stacks that have the potential emissions to cause an effective dose equivalent (EDE) to a maximum exposed individual (MEI) greater than 0.1 mrem y -1 must be monitored continuously for radionuclide emissions. Five methods were approved by EPA, Region 10 for performing the assessments: Release Fractions from Appendix D of 40 CFR 61, Back Calculations Using A HEPA Filtration Factor, Nondestructive Assay of HEPA Filters, A Spill Release Fraction, and Upstream of HEPA Filter Air Concentrations. The first two methods were extremely conservative for estimating releases. The third method which used a state-of-the-art portable gamma spectrometer, yielded surprising results from the distribution of radionuclides on the HEPA filters. All five methods are described

  15. EPA Facility Registry Service (FRS): NCDB

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  16. EPA Facility Registry Service (FRS): BRAC

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  17. EPA Facility Registry Service (FRS): BIA

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  18. EPA Facility Registry Service (FRS): RADINFO

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  19. EPA Facility Registry Service (FRS): TRI

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  20. EPA Facility Registry Service (FRS): ICIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  1. EPA Facility Registry Service (FRS): RBLC

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  2. EPA Facility Registry System (FRS): NCES

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  3. EPA Facility Registry Service (FRS): LANDFILL

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of non-hazardous waste...

  4. EPA Facility Registry Service (FRS): NEI

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  5. EPA Facility Registry Service (FRS): CAMDBS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  6. EPA Facility Registry System (FRS): NEPT

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  7. EPA Facility Registry Service (FRS): SDWIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  8. EPA Facility Registry Service (FRS): RMP

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  9. Green Roof Research through EPA's Regional Applied Research Effort - slides

    Science.gov (United States)

    The U.S. Environmental Protection Agency’s (EPA) Regional Applied Research Effort (RARE) allows the Regions of the EPA to choose research projects to be performed in partnership with EPA’s Office of Research and Development (ORD). Over the last decade, several green roof projects...

  10. 40 CFR 70.8 - Permit review by EPA and affected States.

    Science.gov (United States)

    2010-07-01

    ... compatible with EPA's national database management system. (2) The Administrator may waive the requirements... PROGRAMS (CONTINUED) STATE OPERATING PERMIT PROGRAMS § 70.8 Permit review by EPA and affected States. (a...

  11. Medical reference dosimetry using EPR measurements of alanine

    DEFF Research Database (Denmark)

    Helt-Hansen, Jakob; Rosendal, F.; Kofoed, I.M.

    2009-01-01

    Background. Electron spin resonance (EPR) is used to determine the absorbed dose of alanine dosimeters exposed to clinical photon beams in a solid-water phantom. Alanine is potentially suitable for medical reference dosimetry, because of its near water equivalence over a wide energy spectrum, low...... methods the proposed algorithm can be applied without normalisation of phase shifts caused by changes in the g-value of the cavity. The study shows that alanine dosimetry is a suitable candidate for medical reference dosimetry especially for quality control applications.......Background. Electron spin resonance (EPR) is used to determine the absorbed dose of alanine dosimeters exposed to clinical photon beams in a solid-water phantom. Alanine is potentially suitable for medical reference dosimetry, because of its near water equivalence over a wide energy spectrum, low...

  12. EPA Pacific Southwest Enforcement Division Inspected Tax Map Key Polygons, Hawaii, 2017, US EPA Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — This feature class contains the 64 tax map key polygons across the state of Hawaii that have been inspected by US EPA Pacific Southwest Enforcement Division as of...

  13. Adaptation of penelope Monte Carlo code system to the absorbed dose metrology: characterization of high energy photon beams and calculations of reference dosimeter correction factors

    International Nuclear Information System (INIS)

    Mazurier, J.

    1999-01-01

    This thesis has been performed in the framework of national reference setting-up for absorbed dose in water and high energy photon beam provided with the SATURNE-43 medical accelerator of the BNM-LPRI (acronym for National Bureau of Metrology and Primary standard laboratory of ionising radiation). The aim of this work has been to develop and validate different user codes, based on PENELOPE Monte Carlo code system, to determine the photon beam characteristics and calculate the correction factors of reference dosimeters such as Fricke dosimeters and graphite calorimeter. In the first step, the developed user codes have permitted the influence study of different components constituting the irradiation head. Variance reduction techniques have been used to reduce the calculation time. The phase space has been calculated for 6, 12 and 25 MV at the output surface level of the accelerator head, then used for calculating energy spectra and dose distributions in the reference water phantom. Results obtained have been compared with experimental measurements. The second step has been devoted to develop an user code allowing calculation correction factors associated with both BNM-LPRI's graphite and Fricke dosimeters thanks to a correlated sampling method starting with energy spectra obtained in the first step. Then the calculated correction factors have been compared with experimental and calculated results obtained with the Monte Carlo EGS4 code system. The good agreement, between experimental and calculated results, leads to validate simulations performed with the PENELOPE code system. (author)

  14. EPA/DOE joint efforts on mixed waste treatment

    International Nuclear Information System (INIS)

    Lee, C.C.; Huffman, G.L.; Nalesnik, R.P.

    1995-01-01

    Under the requirements of the Federal Facility Compliance Act (FFCA), the Department of Energy (DOE) is directed to develop treatment plans for their stockpile of wastes generated at their various sites. As a result, DOE is facing the monumental problem associated with the treatment and ultimate disposal of their mixed (radioactive and hazardous) waste. Meanwhile, the Environmental Protection Agency (EPA) issued a final open-quotes Hazardous Waste Combustion Strategyclose quotes in November 1994. Under the Combustion Strategy, EPA permit writers have been given the authority to use the Omnibus Provision of the Resource Conservation and Recovery Act (RCRA) to impose more stringent emission limits for waste combustors prior to the development of new regulations. EPA and DOE established a multi-year Interagency Agreement (IAG) in 1991. The main objective of the IAG (and of the second IAG that was added in 1993) is to conduct a research program on thermal technologies for treating mixed waste and to establish permit procedures for these technologies particularly under the new requirements of the above-mentioned EPA Combustion Strategy. The objective of this Paper is to summarize the results of the EPA/DOE joint efforts on mixed waste treatment since the establishment of the original Interagency Agreement. Specifically, this Paper will discuss six activities that have been underway; namely: (1) National Technical Workgroup (NTW) on Mixed Waste Treatment, (2) State-of-the-Art Assessment of APC (Air Pollution Control) and Monitoring Technologies for the Rocky Flats Fluidized Bed Unit, (3) Initial Study of Permit open-quotes Roadmapclose quotes Development for Mixed Waste Treatment, (4) Risk Assessment Approach for a Mixed Waste Thermal Treatment Facility, (5) Development and Application of Technology Selection Criteria for Mixed Waste Thermal Treatment, and (6) Performance Testing of Mixed Waste Incineration: In-Situ Chlorine Capture in a Fluidized Bed Unit

  15. Human data and internal dose assessment

    International Nuclear Information System (INIS)

    Kawamura, H.; Tanaka, G.; Shiraishi, K.; Yamamoto, M.

    1992-01-01

    Recent data on physical and anatomical and physiological or metabolic data regarding Japanese Reference Man is briefly reviewed. This includes reference values for masses of all organs and tissues proposed for a Japanese Reference male adult. Part of the data is used to assess alpha doses to bone tissues from naturally occurring 226 Ra in bone of Japanese adult. (author)

  16. Concerns raised over new EPA members

    Science.gov (United States)

    Gwynne, Peter

    2017-12-01

    The Trump administration has nominated three new members of the Environmental Protection Agency (EPA) who critics say are undermining laws and “pampering” the industries they are supposed to regulate.

  17. EPA Facility Registry Service (FRS): OIL

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Oil...

  18. Patient dose surveys for radiological examinations in Dutch hospitals between 1993 and 2000

    International Nuclear Information System (INIS)

    Spoelstra, F.M.; Geleijns, J.; Broerse, J.J.; Teeuwisse, W.M.; Zweers, D.

    2001-01-01

    Our inventory studies on radiation dose to patients in Dutch hospitals are reviewed and compared with current European guidelines on patient dose and reference dose values of the NRPB. Between the years 1993 and 2000 doses were measured and effective dose was assessed at 14 hospitals for paediatric radiography, at 18 hospitals for PA chest radiography, at 10 respectively 9 hospitals for barium meal and barium enema examinations and at 18 hospitals for CT scans of the brain, chest (including high resolution CT of the chest), abdomen and lumbar spine in The Netherlands. Effective doses varied from 1 μSv (AP chest radiograph premature) to 26 mSv (CT abdomen scan). Doses were in general well below the reference dose values, with the exception of CT where the dose length product often exceeded reference levels. Interhospital variations were considerable, the largest range was observed for PA chest examinations, i.e.a ratio of 27 between maximum and minimum effective dose. (author)

  19. Hispanos en la EPA: Neftalí Hernández-Santiago

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  20. Internal dose conversion factors for calculation of dose to the public

    International Nuclear Information System (INIS)

    1988-07-01

    This publication contains 50-year committed dose equivalent factors, in tabular form. The document is intended to be used as the primary reference by the US Department of Energy (DOE) and its contractors for calculating radiation dose equivalents for members of the public, resulting from ingestion or inhalation of radioactive materials. Its application is intended specifically for such materials released to the environment during routine DOE operations, except in those instances where compliance with 40 CFR 61 (National Emission Standards for Hazardous Air Pollutants) requires otherwise. However, the calculated values may be equally applicable to unusual releases or to occupational exposures. The use of these committed dose equivalent tables should ensure that doses to members of the public from internal exposures are calculated in a consistent manner at all DOE facilities

  1. 78 FR 13872 - Proposed Information Collection Request; Comment Request; EPA's WaterSense Program (Renewal); EPA...

    Science.gov (United States)

    2013-03-01

    ... profanity, threats, information claimed to be Confidential Business Information (CBI) or other information...-efficient products and use water-efficient practices. As part of strategic planning efforts, EPA encourages... Reporting Form Promotional partners 6100-09 Manufacturers (separate forms for plumbing and non- plumbing...

  2. Construction of average adult Japanese voxel phantoms for dose assessment

    International Nuclear Information System (INIS)

    Sato, Kaoru; Takahashi, Fumiaki; Satoh, Daiki; Endo, Akira

    2011-12-01

    The International Commission on Radiological Protection (ICRP) adopted the adult reference voxel phantoms based on the physiological and anatomical reference data of Caucasian on October, 2007. The organs and tissues of these phantoms were segmented on the basis of ICRP Publication 103. In future, the dose coefficients for internal dose and dose conversion coefficients for external dose calculated using the adult reference voxel phantoms will be widely used for the radiation protection fields. On the other hand, the body sizes and organ masses of adult Japanese are generally smaller than those of adult Caucasian. In addition, there are some cases that the anatomical characteristics such as body sizes, organ masses and postures of subjects influence the organ doses in dose assessment for medical treatments and radiation accident. Therefore, it was needed to use human phantoms with average anatomical characteristics of Japanese. The authors constructed the averaged adult Japanese male and female voxel phantoms by modifying the previously developed high-resolution adult male (JM) and female (JF) voxel phantoms. It has been modified in the following three aspects: (1) The heights and weights were agreed with the Japanese averages; (2) The masses of organs and tissues were adjusted to the Japanese averages within 10%; (3) The organs and tissues, which were newly added for evaluation of the effective dose in ICRP Publication 103, were modeled. In this study, the organ masses, distances between organs, specific absorbed fractions (SAFs) and dose conversion coefficients of these phantoms were compared with those evaluated using the ICRP adult reference voxel phantoms. This report provides valuable information on the anatomical and dosimetric characteristics of the averaged adult Japanese male and female voxel phantoms developed as reference phantoms of adult Japanese. (author)

  3. Referent 3D tumor model at cellular level in radionuclide therapy

    International Nuclear Information System (INIS)

    Spaic, R.; Ilic, R.D.; Petrovic, B.J.

    2002-01-01

    Aim Conventional internal dosimetry has a lot of limitations because of tumor dose nonuniformity. The best approach for absorbed dose at cellular level for different tumors in radionuclide therapy calculation is Monte Carlo method. The purpose of this study is to introduce referent tumor 3D model at cellular level for Monte Carlo simulation study in radionuclide therapy. Material and Methods The moment when tumor is detectable and when same therapy can start is time period in which referent 3D tumor model at cellular level was defined. In accordance with tumor growth rate at that moment he was a sphere with same radius (10 000 μm). In that tumor there are cells or cluster of cells, which are randomly distributed spheres. Distribution of cells/cluster of cells can be calculated from histology data but it was assumed that this distribution is normal with the same mean value and standard deviation (100±50 mm). Second parameter, which was selected to define referent tumor, is volume density of cells (30%). In this referent tumor there are no necroses. Stroma is defined as space between spheres with same concentration of materials as in spheres. Results: Referent tumor defined on this way have about 2,2 10 5 cells or cluster of cells random distributed. Using this referent 3D tumor model and for same concentration of radionuclides (1:100) and energy of beta emitters (1000 keV) which are homogeneously distributed in labeled cells absorbed dose for all cells was calculated. Simulations are done using FOTELP Monte Carlo code, which is modified for this purposes. Results of absorbed dose in cells are given in numerical values (1D distribution) and as the images (2D or 3D distributions). Conclusion Geometrical module for Monte Carlo simulation study can be standardized by introducing referent 3D tumor model at cellular level. This referent 3D tumor model gives most realistic presentation of different tumors at the moment of their detectability. Referent 3D tumor model at

  4. EPA Center for Corporate Climate Leadership

    Science.gov (United States)

    EPA's Center for Corporate Climate Leadership is a comprehensive resource to help organizations measure & manage GHG emissions. The Center provides technical tools, educational resources, opportunities for information sharing & highlights best practices.

  5. EPA CIO Governance Board Membership List

    Science.gov (United States)

    In keeping with OMB guidance on implementing the Federal Information Technology Reform Act (FITARA), EPA is publishing its list of officials who perform the duties or responsibilities of a Bureau CIO.

  6. EPA Administrative Law Judge Legal Documents

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains Decisions and Orders originating from EPAs Office of Administrative Law Judges (OALJ), which is an independent office in the Office of the...

  7. 2013 EPA Vessels General Permit (VGP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Information for any vessel that submitted a Notice of Intent (NOI), Notice of Termination (NOT), or annual report under EPA's 2013 Vessel General Permit (VGP)....

  8. EPA Facility Registry Service (FRS): ACRES

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service consists of location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of sites that link to...

  9. IRIS Toxicological Review of Dichloromethane (Methylene ...

    Science.gov (United States)

    EPA has finalized the Toxicological Review of Dichloromethane (Methylene Chloride): In support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health. This document presents background information and justification for the Intergrated Risk Information System (IRIS) Summary of the hazard and dose-response assessment of dichloromethane. IRIS Summaries may include oral reference dose (RfD) and inhalation reference concentration (RfC) values for chronic and other exposure durations, and a carcinogencity assessment. Internet/NCEA web site

  10. Doses from radioactive methane

    International Nuclear Information System (INIS)

    Phipps, A.W.; Kendall, G.M.; Fell, T.P.; Harrison, J.D.

    1990-01-01

    A possible radiation hazard arises from exposure to methane labelled with either a 3 H or a 14 C nuclide. This radioactive methane could be released from a variety of sources, e.g. land burial sites containing radioactive waste. Standard assumptions adopted for vapours would not apply to an inert alkane like methane. This paper discusses mechanisms by which radioactive methane would irradiate tissues and provides estimates of doses. Data on skin thickness and metabolism of methane are discussed with reference to these mechanisms. It is found that doses are dominated by dose from the small fraction of methane which is inhaled and metabolised. This component of dose has been calculated under rather conservative assumptions. (author)

  11. Evaluation of mercury speciation by EPA (Draft) Method 29

    Energy Technology Data Exchange (ETDEWEB)

    Laudal, D.L.; Heidt, M.K. [Energy & Environmental Research Center, Grand Forks, ND (United States); Nott, B. [Electric Power Research Institute, Palo Alto, CA (United States)

    1995-11-01

    The 1990 Clean Air Act Amendments require that the U.S. Environmental protection Agency (EPA) assess the health risks associated with mercury emissions. Also, the law requires a separate assessment of health risks posed by the emission of 189 tract chemicals (including mercury) for electric utility steam-generating units. In order to conduct a meaningful assessment of health and environmental effects, we must have, among other things, a reliable and accurate method to measure mercury emissions. In addition, the rate of mercury deposition and the type of control strategies used may depend upon the type of mercury emitted (i.e., whether it is in the oxidized or elemental form). It has been speculated that EPA (Draft) Method 29 can speciate mercury by selective absorption; however, this claim has yet to be proven. The Electric Power Research Institute (EPRI) and the U.S. Department of Energy (DOE) have contracted with the Energy & Environmental Research Center (EERC) at University of North Dakota to evaluate EPA (Draft) Method 29 at the pilot-scale level. The objective of the work is to determine whether EPA (Draft) Method 29 can reliably quantify and speciate mercury in the flue gas from coal-fired boilers.

  12. Scenario sensitivity analyses performed on the PRESTO-EPA LLW risk assessment models

    International Nuclear Information System (INIS)

    Bandrowski, M.S.

    1988-01-01

    The US Environmental Protection Agency (EPA) is currently developing standards for the land disposal of low-level radioactive waste. As part of the standard development, EPA has performed risk assessments using the PRESTO-EPA codes. A program of sensitivity analysis was conducted on the PRESTO-EPA codes, consisting of single parameter sensitivity analysis and scenario sensitivity analysis. The results of the single parameter sensitivity analysis were discussed at the 1987 DOE LLW Management Conference. Specific scenario sensitivity analyses have been completed and evaluated. Scenario assumptions that were analyzed include: site location, disposal method, form of waste, waste volume, analysis time horizon, critical radionuclides, use of buffer zones, and global health effects

  13. Dosimetric analysis at ICRU reference points in HDR-brachytherapy of cervical carcinoma.

    Science.gov (United States)

    Eich, H T; Haverkamp, U; Micke, O; Prott, F J; Müller, R P

    2000-01-01

    In vivo dosimetry in bladder and rectum as well as determining doses on suggested reference points following the ICRU report 38 contribute to quality assurance in HDR-brachytherapy of cervical carcinoma, especially to minimize side effects. In order to gain information regarding the radiation exposure at ICRU reference points in rectum, bladder, ureter and regional lymph nodes those were calculated (digitalisation) by means of orthogonal radiographs of 11 applications in patients with cervical carcinoma, who received primary radiotherapy. In addition, the doses at the ICRU rectum reference point was compared to the results of in vivo measurements in the rectum. The in vivo measurements were by factor 1.5 below the doses determined for the ICRU rectum reference point (4.05 +/- 0.68 Gy versus 6.11 +/- 1.63 Gy). Reasons for this were: calibration errors, non-orthogonal radiographs, movement of applicator and probe in the time span between X-ray and application, missing connection of probe and anterior rectal wall. The standard deviation of calculations at ICRU reference points was on average +/- 30%. Possible reasons for the relatively large standard deviation were difficulties in defining the points, identifying them on radiographs and the different locations of the applicators. Although 3 D CT, US or MR based treatment planning using dose volume histogram analysis is more and more established, this simple procedure of marking and digitising the ICRU reference points lengthened treatment planning only by 5 to 10 minutes. The advantages of in vivo dosimetry are easy practicability and the possibility to determine rectum doses during radiation. The advantages of computer-aided planning at ICRU reference points are that calculations are available before radiation and that they can still be taken into account for treatment planning. Both methods should be applied in HDR-brachytherapy of cervical carcinoma.

  14. Environmental Change in Post-closure Safety Assessment of Solid Radioactive Waste Repositories. Report of Working Group 3 Reference Models for Waste Disposal of EMRAS II Topical Heading Reference Approaches for Human Dose Assessment. Environmental Modelling for Radiation Safety (EMRAS II) Programme

    International Nuclear Information System (INIS)

    2016-08-01

    Environmental assessment models are used for evaluating the radiological impact of actual and potential releases of radionuclides to the environment. They are essential tools for use in the regulatory control of routine discharges to the environment and also in planning measures to be taken in the event of accidental releases. They are also used for predicting the impact of releases which may occur far into the future, for example, from underground radioactive waste repositories. It is important to verify, to the extent possible, the reliability of the predictions of such models by a comparison with measured values in the environment or with predictions of other models. The IAEA has been organizing programmes of international model testing since the 1980s. These programmes have contributed to a general improvement in models, in the transfer of data and in the capabilities of modellers in Member States. IAEA publications on this subject over the past three decades demonstrate the comprehensive nature of the programmes and record the associated advances which have been made. From 2009 to 2011, the IAEA organized a programme entitled Environmental Modelling for Radiation Safety (EMRAS II), which concentrated on the improvement of environmental transfer models and the development of reference approaches to estimate the radiological impacts on humans, as well as on flora and fauna, arising from radionuclides in the environment. Different aspects were addressed by nine working groups covering three themes: reference approaches for human dose assessment, reference approaches for biota dose assessment and approaches for assessing emergency situations. This publication describes the work of the Reference Models for Waste Disposal Working Group

  15. 48 CFR 1552.223-71 - EPA Green Meetings and Conferences.

    Science.gov (United States)

    2010-10-01

    ... provision or language substantially the same as the provision in solicitations for meetings and conference services. EPA Green Meetings and Conferences (MAY 2007) (a) The mission of the EPA is to protect human... information about environmentally preferable features and practices your facility will have in place for the...

  16. Dose reduction in evacuation proctography

    International Nuclear Information System (INIS)

    Hare, C.; Halligan, S.; Bartram, C.I.; Gupta, R.; Walker, A.E.; Renfrew, I.

    2001-01-01

    The goal of this study was to reduce the patient radiation dose from evacuation proctography. Ninety-eight consecutive adult patients referred for proctography to investigate difficult rectal evacuation were studied using a digital imaging system with either a standard digital program for barium examinations, a reduced dose digital program (both with and without additional copper filtration), or Video fluoroscopy. Dose-area products were recorded for each examination and the groups were compared. All four protocols produced technically acceptable examinations. The low-dose program with copper filtration (median dose 382 cGy cm 2 ) and Video fluoroscopy (median dose 705 cGy cm 2 ) were associated with significantly less dose than other groups (p < 0.0001). Patient dose during evacuation proctography can be reduced significantly without compromising the diagnostic quality of the examination. A digital program with added copper filtration conveyed the lowest dose. (orig.)

  17. EPA Region 6 REAP Composite Geodatabse

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Regional Ecological Assessment Protocol (REAP) is a screening level tool created as a way to identify priority ecological resources within the five EPA Region 6...

  18. Meet EPA Researcher Endalkachew Sahle-Demessie

    Science.gov (United States)

    Meet EPA Researcher Endalkachew Sahle-Demessie. Chemical and Environmental Engineer Endalkachew Sahle-Demessie, Ph.D., works on various projects, including nanomaterials and water resources, in EPA’s National Risk Management Research Laboratory.

  19. EPA Region 1 Sole Source Aquifers

    Data.gov (United States)

    U.S. Environmental Protection Agency — This coverage contains boundaries of EPA-approved sole source aquifers. Sole source aquifers are defined as an aquifer designated as the sole or principal source of...

  20. EPA Region 6 REAP Diversity Geodatabase

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Regional Ecological Assessment Protocol (REAP) is a screening level tool created as a way to identify priority ecological resources within the five EPA Region 6...

  1. Quantitative simulation of intracellular signaling cascades in a Virtual Liver: estimating dose dependent changes in hepatocellular proliferation and apoptosis

    Science.gov (United States)

    The US EPA Virtual Liver (v-Liver™) is developing an approach to predict dose-dependent hepatotoxicity as an in vivo tissue level response using in vitro data. The v-Liver accomplishes this using an in silico agent-based systems model that dynamically integrates environmental exp...

  2. Reference values for heavy metals in soils of the Brazilian agricultural frontier in Southwestern Amazônia.

    Science.gov (United States)

    dos Santos, Sabrina Novaes; Alleoni, Luís Reynaldo Ferracciú

    2013-07-01

    Guideline values are used to identify polluted or contaminated areas based on background values. Brazilian law establishes three guideline values for pollutants: a quality reference value (QRV), a prevention value, and an intervention value. Reference values refer to the natural concentration of an element or a substance in soils that have not been modified by anthropogenic impacts. These values inform assessments of soil quality and are used to establish maximum permissible limits. The objective of this study was to determine the natural levels and reference values for Cd, Co, Cr, Cu, Ni, Pb, and Zn in samples from the surface layer (0-20 cm) of 19 representative soils of the states of Mato Grosso and Rondônia, on Brazil's agricultural frontier. Pseudo-total metal concentrations were obtained following microwave-assisted digestion using the aqua regia and EPA3051 methods. QRVs were calculated for each element as the 75th and 90th percentiles of the frequency distribution of the data. Natural levels of heavy metals in the soil samples followed the order: Cr > Zn > Cu > Co > Pb > Ni > and Cd (aqua regia) and Cr > Co > Cu > Pb > Zn > Ni > Cd (EPA3051). These values are generally lower than those reported in the Brazilian and international literature, which highlights the importance of establishing reference values for each state or for each soil type, taking into account the geomorphological, pedological, and geological diversity of the region under study.

  3. Standardization of high-dose measurement of electron and gamma ray absorbed doses and dose rates

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1985-01-01

    Intense electron beams and gamma radiation fields are used for sterilizing medical devices, treating municipal wastes, processing industrial goods, controlling parasites and pathogens, and extending the shelf-life of foods. Quality control of such radiation processes depends largely on maintaining measurement quality assurance through sound dosimetry procedures in the research leading to each process, in the commissioning of that process, and in the routine dose monitoring practices. This affords documentation as to whether satisfactory dose uniformity is maintained throughout the product and throughout the process. Therefore, dosimetry at high doses and dose rates must in many radiation processes be standardized carefully, so that 'dosimetry release' of a product is verified. This standardization is initiated through preliminary dosimetry intercomparison studies such as those sponsored recently by the IAEA. This is followed by establishing periodic exercises in traceability to national or international standards of absorbed dose and dose rate. Traceability is achieved by careful selection of dosimetry methods and proven reference dosimeters capable of giving sufficiently accurate and precise 'transfer' dose assessments: (1) they must be calibrated or have well-established radiation-yield indices; (2) their radiation response characteristics must be reproducible and cover the dose range of interest; (3) they must withstand the rigours of back-and-forth mailing between a central standardizing laboratory and radiation processing facilities, without excessive errors arising due to instabilities, dosimeter batch non-uniformities, and environmental and handling stresses. (author)

  4. Incorporation of detailed eye model into polygon-mesh versions of ICRP-110 reference phantoms.

    Science.gov (United States)

    Nguyen, Thang Tat; Yeom, Yeon Soo; Kim, Han Sung; Wang, Zhao Jun; Han, Min Cheol; Kim, Chan Hyeong; Lee, Jai Ki; Zankl, Maria; Petoussi-Henss, Nina; Bolch, Wesley E; Lee, Choonsik; Chung, Beom Sun

    2015-11-21

    The dose coefficients for the eye lens reported in ICRP 2010 Publication 116 were calculated using both a stylized model and the ICRP-110 reference phantoms, according to the type of radiation, energy, and irradiation geometry. To maintain consistency of lens dose assessment, in the present study we incorporated the ICRP-116 detailed eye model into the converted polygon-mesh (PM) version of the ICRP-110 reference phantoms. After the incorporation, the dose coefficients for the eye lens were calculated and compared with those of the ICRP-116 data. The results showed generally a good agreement between the newly calculated lens dose coefficients and the values of ICRP 2010 Publication 116. Significant differences were found for some irradiation cases due mainly to the use of different types of phantoms. Considering that the PM version of the ICRP-110 reference phantoms preserve the original topology of the ICRP-110 reference phantoms, it is believed that the PM version phantoms, along with the detailed eye model, provide more reliable and consistent dose coefficients for the eye lens.

  5. High-EPA Biomass from Nannochloropsis salina Cultivated in a Flat-Panel Photo-Bioreactor on a Process Water-Enriched Growth Medium

    Directory of Open Access Journals (Sweden)

    Hamed Safafar

    2016-07-01

    Full Text Available Nannochloropsis salina was grown on a mixture of standard growth media and pre-gasified industrial process water representing effluent from a local biogas plant. The study aimed to investigate the effects of enriched growth media and cultivation time on nutritional composition of Nannochloropsis salina biomass, with a focus on eicosapentaenoic acid (EPA. Variations in fatty acid composition, lipids, protein, amino acids, tocopherols and pigments were studied and results compared to algae cultivated on F/2 media as reference. Mixed growth media and process water enhanced the nutritional quality of Nannochloropsis salina in laboratory scale when compared to algae cultivated in standard F/2 medium. Data from laboratory scale translated to the large scale using a 4000 L flat panel photo-bioreactor system. The algae growth rate in winter conditions in Denmark was slow, but results revealed that large-scale cultivation of Nannochloropsis salina at these conditions could improve the nutritional properties such as EPA, tocopherol, protein and carotenoids compared to laboratory-scale cultivated microalgae. EPA reached 44.2% ± 2.30% of total fatty acids, and α-tocopherol reached 431 ± 28 µg/g of biomass dry weight after 21 days of cultivation. Variations in chemical compositions of Nannochloropsis salina were studied during the course of cultivation. Nannochloropsis salina can be presented as a good candidate for winter time cultivation in Denmark. The resulting biomass is a rich source of EPA and also a good source of protein (amino acids, tocopherols and carotenoids for potential use in aquaculture feed industry.

  6. Electrostatic Plasma Accelerator (EPA)

    Science.gov (United States)

    Brophy, John R.; Aston, Graeme

    1995-01-01

    The application of electric propulsion to communications satellites, however, has been limited to the use of hydrazine thrusters with electric heaters for thrust and specific impulse augmentation. These electrothermal thrusters operate at specific impulse levels of approximately 300 s with heater powers of about 500 W. Low power arcjets (1-3 kW) are currently being investigated as a way to increase specific impulse levels to approximately 500 s. Ion propulsion systems can easily produce specific impulses of 3000 s or greater, but have yet to be applied to communications satellites. The reasons most often given for not using ion propulsion systems are their high level of overall complexity, low thrust with long burn times, and the difficulty of integrating the propulsion system into existing commercial spacecraft busses. The Electrostatic Plasma Accelerator (EPA) is a thruster concept which promises specific impulse levels between low power arcjets and those of the ion engine while retaining the relative simplicity of the arcjet. The EPA thruster produces thrust through the electrostatic acceleration of a moderately dense plasma. No accelerating electrodes are used and the specific impulse is a direct function of the applied discharge voltage and the propellant atomic mass.

  7. Comments on EPA's LLW preproposal

    International Nuclear Information System (INIS)

    Littleton, B.K.; Weinstock, L.

    1995-01-01

    The Environmental Protection Agency (EPA) is currently developing standards for the management, storage, and disposal of Low-Level Radioactive Waste (LLW). The Atomic Energy Act delegated EPA, among other provisions, the authority to establish generally applicable standards for the disposal of radioactive waste to ensure that the public and the environment are adequately protected from potential radiation impacts. As an initial effort to open communications on a standard for LLW, the Agency developed a preproposal draft (Preproposal Draft of 40 CFR Part 193 - 30 Nov 94) and circulated it to interested parties for review and comment. The extended comment period ended April 12, 1995. A summary of the comments received and analyzed to date follows. After all comments have been analyzed, the rule will undergo an Agency clearance process and be sent to the Office of Management and Budget for review. After that review, the formal process of publication of the proposed rule in the Federal Register and the formal public comment period will begin

  8. Radiation doses from paediatric x-ray examinations in some hospitals in Khartoum Area

    International Nuclear Information System (INIS)

    Elshiekh, E.H.A.

    2007-10-01

    The aim of study was to evaluate the entrance surface doses (ESDs) and the effective dose (ED) to patients undergoing some common diagnostic x-ray examinations in large paediatric public hospitals in Khartoum State. ESD per examination was estimated from x-ray tube parameters in three hospitals comprising three units and sample of 449 radiographs. The entrance surface dose (ESD) and the effective dose (ED) were evaluated for chest, skull, abdomen, lumbar spine, and pelvis in antero-posterior (AP), postero-anterior (PA) and lateral (LAT) projections. For each examination, four age groups 0-1, 1-5, 5-10 and 10-15 years were studied. The DoseCal software was used to calculate these doses. In comparison between Sudanese hospitals with NRPB reference levels, all hospitals showed lower doses than reference levels except for the case of chest in A. Gasim and Khartoum hospitals. Wide variations for the chest examination have been detected. These variation were evident, in Sudan, from previous work. ESDs at Omdurman Hospital meet the reference levels for all years range. ESDs at Omdurman hospital were found to be 41μGy and 62 μGy for range 0-1 year, and 1-5 years, respectively, ESDs at A. Gasim Hospital was found found to be 65 μGy and 100 μGy for range 0-1 year, and 1-5 years, respectively. These values are above NRPB reference levels but lower than CEC1996 reference levels, and meet NRPB reference dose levels in range 5-10 years. In Khartoum Hospital the results present higher ESD than NRPB and CEC reference levels. The high ESDs reflect that ALARA principle is not being applied in chest examinations in Sudan. From comparison between results in this work with previous performed for chest cases in these Sudanese Hospitals at 2004, the ESDs in A. Gasim Hospital were above the previous result but meet the reference levels only range 5-10 years. Omdurman Hospital result but meet the reference levels for all years ranges and are lower than 2002 results. Khartoum Hospital

  9. An absorbed dose calorimeter for IMRT dosimetry

    International Nuclear Information System (INIS)

    Duane, S.; Aldehaybes, M.; Bailey, M.; Lee, N.D.; Thomas, C.G.; Palmans, H.

    2012-01-01

    A new calorimeter for dosimetry in small and complex fields has been built. The device is intended for the direct determination of absorbed dose to water in moderately small fields and in composite fields such as IMRT treatments, and as a transfer instrument calibrated against existing absorbed dose standards in conventional reference conditions. The geometry, materials and mode of operation have been chosen to minimize detector perturbations when used in a water phantom, to give a reasonably isotropic response and to minimize the effects of heat transfer when the calorimeter is used in non-reference conditions in a water phantom. The size of the core is meant to meet the needs of measurement in IMRT treatments and is comparable to the size of the air cavity in a type NE2611 ionization chamber. The calorimeter may also be used for small field dosimetry. Initial measurements in reference conditions and in an IMRT head and neck plan, collapsed to gantry angle zero, have been made to estimate the thermal characteristics of the device, and to assess its performance in use. The standard deviation (estimated repeatability) of the reference absorbed dose measurements was 0.02 Gy (0.6%). (authors)

  10. Adaptation of penelope Monte Carlo code system to the absorbed dose metrology: characterization of high energy photon beams and calculations of reference dosimeter correction factors; Adaptation du code Monte Carlo penelope pour la metrologie de la dose absorbee: caracterisation des faisceaux de photons X de haute energie et calcul de facteurs de correction de dosimetres de reference

    Energy Technology Data Exchange (ETDEWEB)

    Mazurier, J

    1999-05-28

    This thesis has been performed in the framework of national reference setting-up for absorbed dose in water and high energy photon beam provided with the SATURNE-43 medical accelerator of the BNM-LPRI (acronym for National Bureau of Metrology and Primary standard laboratory of ionising radiation). The aim of this work has been to develop and validate different user codes, based on PENELOPE Monte Carlo code system, to determine the photon beam characteristics and calculate the correction factors of reference dosimeters such as Fricke dosimeters and graphite calorimeter. In the first step, the developed user codes have permitted the influence study of different components constituting the irradiation head. Variance reduction techniques have been used to reduce the calculation time. The phase space has been calculated for 6, 12 and 25 MV at the output surface level of the accelerator head, then used for calculating energy spectra and dose distributions in the reference water phantom. Results obtained have been compared with experimental measurements. The second step has been devoted to develop an user code allowing calculation correction factors associated with both BNM-LPRI's graphite and Fricke dosimeters thanks to a correlated sampling method starting with energy spectra obtained in the first step. Then the calculated correction factors have been compared with experimental and calculated results obtained with the Monte Carlo EGS4 code system. The good agreement, between experimental and calculated results, leads to validate simulations performed with the PENELOPE code system. (author)

  11. SU-F-P-19: Fetal Dose Estimate for a High-Dose Fluoroscopy Guided Intervention Using Modern Data Tools

    Energy Technology Data Exchange (ETDEWEB)

    Moirano, J [University of Washington, Seattle, WA (United States)

    2016-06-15

    Purpose: An accurate dose estimate is necessary for effective patient management after a fetal exposure. In the case of a high-dose exposure, it is critical to use all resources available in order to make the most accurate assessment of the fetal dose. This work will demonstrate a methodology for accurate fetal dose estimation using tools that have recently become available in many clinics, and show examples of best practices for collecting data and performing the fetal dose calculation. Methods: A fetal dose estimate calculation was performed using modern data collection tools to determine parameters for the calculation. The reference point air kerma as displayed by the fluoroscopic system was checked for accuracy. A cumulative dose incidence map and DICOM header mining were used to determine the displayed reference point air kerma. Corrections for attenuation caused by the patient table and pad were measured and applied in order to determine the peak skin dose. The position and depth of the fetus was determined by ultrasound imaging and consultation with a radiologist. The data collected was used to determine a normalized uterus dose from Monte Carlo simulation data. Fetal dose values from this process were compared to other accepted calculation methods. Results: An accurate high-dose fetal dose estimate was made. Comparison to accepted legacy methods were were within 35% of estimated values. Conclusion: Modern data collection and reporting methods ease the process for estimation of fetal dose from interventional fluoroscopy exposures. Many aspects of the calculation can now be quantified rather than estimated, which should allow for a more accurate estimation of fetal dose.

  12. EPA's LLW standards program: Below regulatory concern criteria development

    International Nuclear Information System (INIS)

    Holcomb, W.F.; Gruhlke, J.M.

    1987-01-01

    The Environmental Protection Agency (EPA) is developing generally applicable environmental standards for land disposal of low-level radioactive wastes. These standards will include criteria for determining which wastes have sufficiently low levels of radioactivity to be considered ''Below Regulatory Concern'' (BRC) in regards to their radiation hazard. Risk assessments to support the BRC criteria include an analysis of 18 surrogate radioactive waste streams, generated by nuclear power reactors and other fuel cycle facilities, industrial, medical and educational facilities, and consumers. Deregulated disposal alternatives, such as sanitary landfills, municipal dumps, incinerators and on-site landfills, situated in diverse demographic settings are used in the analysis. A number of waste streams which contributed only small doses or fractions of a health effect over 10,000 years were identified. Disposal of such wastes without consideration of their very low radioactivity could result in significant cost savings to the commercial fuel cycle and government operations as well as to medical, educational, and industrial facilities, and with minimal risk to the public. The concept of BRC wastes appears both feasible and cost effective

  13. The reference individual of radiation protection

    International Nuclear Information System (INIS)

    Eckerman, K.F.; Cristy, M.

    1995-01-01

    The 70-kg open-quotes standard manclose quotes representing a typical Western adult male has been used in physiological models since at least the 1920s. In 1949 at the Chalk River conference, health physicists from the U.S., UK, and Canada agreed on the concept of a standard man to facilitate comparison of internal dose estimates. The 70-kg standard man included specifications of the masses of 25 organs and tissues, total body content of 15 elements, total water intake and output, water content of the body, and some anatomical and physiological data for the respiratory and gastrointestinal tracts. In 1959, in its Publication 2 2 on permissible doses for internal radiation the International Commission on Radiological Protection (ICRP) modified standard man. In 1963 the ICRP established a task group to revise and extend the standard man concept. The name was changed later to Reference Man and the task group's work was published in 1975 as ICRP Publication 23 3 . Publication 23 similar to Publication 2, updates and documents the sources of the data. Data on women, children, and fetuses were also collected, where available, but these data were limited primarily to anatomical data and only a few reference values were established for these groups. Information assembled during the course of the effort on the Reference Man report was used at Oak Ridge National Laboratory (ORNL) to construct a mathematical representation of the body (a phantom) that was suitable for use with Monte Carlo methods in the calculation of organ doses. That effort was undertaken to improve estimates of dose from photon-emitting radionuclides residing within organs, so-called internal emitters. The phantom, although updated throughout the years, remains today as the basis for organ dose estimates in nuclear medicine and radiation protection and underlies the radiation risk data derived from the epidemiologic studies of the atomic bomb survivors of Hiroshima and Nagasaki

  14. Environmental Protection Agency - EPA Pub Central

    Data.gov (United States)

    U.S. Environmental Protection Agency — PubMed Central (PMC) is a full-text, online archive of journal literature operated by the National Library of Medicine. The EPA is using PMC to permanently preserve...

  15. Diagnostic Reference Levels in the 1990 and 1996 Recommendations of the ICRP (invited paper)

    International Nuclear Information System (INIS)

    Drexler, G.

    1998-01-01

    A review of and some comments on the paragraphs in the ICRP Publications 60 and 73 are presented, which are relevant to diagnostic reference doses. The content of the statements is traced back by approximately 50 years when ICRP's preoccupation with the future health and well-being of the population is reflected in guidance for characterisation of 'normal operational conditions'. The early ICRP levels of reference doses are compared with the values currently discussed to demonstrate the importance of diagnostic reference doses in the process of optimisation and to show the importance of a continuous review and update of these levels. (author)

  16. 40 CFR 131.22 - EPA promulgation of water quality standards.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false EPA promulgation of water quality... PROGRAMS WATER QUALITY STANDARDS Procedures for Review and Revision of Water Quality Standards § 131.22 EPA promulgation of water quality standards. (a) If the State does not adopt the changes specified by the Regional...

  17. Comparative study of dose descriptor in pediatric computed tomography exams

    International Nuclear Information System (INIS)

    Finatto, Jerusa Dalbosco; Silva, Ana Maria Marques da; Froner, Ana Paula Pastre; Pimentel, Juliana

    2014-01-01

    This work aims to investigate the dose descriptor, volumetric Computed Tomography Dose Index (CTDI), a pediatric patients sample undergoing to skull CT, comparing the results with the diagnostic reference levels of the literature. Were collected volumetric CTDI values of all skull CT exams performed retrospectively in children of 0-10 years of age in a period of 12 months in a large hospital size. Patients, in a total of 103, were divided into four groups, where the criterion of separation used was age, trying to use the same division used in international references dose descriptors. In all acquisitions we used the pediatric protocol and the Automatic Exposure Control (AEC) available on the equipment. The CDTI values, with and without the use of AEC for pediatric studies, were compared. There was a reduction of approximately 100% in the absorbed dose value due to the use of the AEC. From the data collected and analyzed in this work, it is concluded that the use of dose reduction systems is relevant, such as the Care Dose, to maintain volumetric CTDI values within the reference levels. Also it is important the observation of range of children age to the appropriate choice of parameters used in the test protocol. The values obtained are according to the diagnostic reference levels from the literature

  18. 76 FR 27315 - EPA Science Advisory Board Staff Invitation to a Session on Public Involvement in EPA Advisory...

    Science.gov (United States)

    2011-05-11

    ... and SAB Three inter-related public access Web sites ( http://www.epa.gov/advisorycouncilcaa , http...) ``Recent Happenings'' and ``Recent Additions'' sections and related ``really simple syndication'' (RSS...

  19. Determination of Absorbed Dose Using a Dosimetric Film

    International Nuclear Information System (INIS)

    Scarlat, F.; Scarisoreanu, A.; Oane, M.; Badita, E.; Mitru, E.

    2009-01-01

    This paper presents the absorbed dose measurements by means of the irradiated dosimetric reference films. The dose distributions were made by MULTIDATA film densitometer using RTD-4 software, in INFLPR Linear Accelerator Department

  20. Regulatory decision with EPA/NRC/DOE/State Session (Panel)

    Energy Technology Data Exchange (ETDEWEB)

    O`Donnell, E.

    1995-12-31

    This panel will cover the Nuclear Regulatory Commission`s (NRC) proposed radiation limits in the Branch Technical Position on Low-Level Radioactive Waste Performance Assessment and the Environmental Protection Agency`s (EPA) draft regulation in Part 193. Representatives from NRC and EPA will discuss the inconsistencies in these two regulations. DOE and state representatives will discuss their perspective on how these regulations will affect low-level radioactive waste performance assessments.