WorldWideScience

Sample records for epa radon program

  1. First year evaluation of EPA's radon contractor proficiency (RCP) program

    International Nuclear Information System (INIS)

    Salmon, G.L.

    1990-01-01

    This paper reports that the Environmental Protection Agency (EPA) has developed a voluntary program to evaluate radon reduction contractors and provide this information to the public, as part of activities mandated by the Indoor Radon Abatement Act (IRAA) of 1988. The Radon Contractor Proficiency Program consists of several elements that collectively help to ensure the proficiency of radon mitigators and give the public greater confidence in their capability. Contractors who participate in the program must pass a written examination, adhere to mitigation guidelines, keep records of work, meet continuing education requirements and pass a re-examination every two years. Upon meeting the program's requirements, mitigators are listed in EPA's National RCP Proficiency Report. The first Report released on May 15, 1990 listed 636 contractors. The second Report, to be release in August, will list 895 contractors, representing an increase of 40 per cent

  2. EPA'S strategy to reduce risk of radon

    International Nuclear Information System (INIS)

    Page, S.

    1993-01-01

    The Indoor Radon Abatement Act of 1988 (IRAA) directed EPA to undertake a variety of activities to address the growing public concern over dangers posed by exposure to indoor radon. Among other requirements, the law directed the Agency to study radon levels, evaluate mitigation methods, establish proficiency programs, assist states with program development, develop training centers, and provide public information. EPA has developed and implemented programs to address each of the key provisions of this statute. This paper presents EPA's broad national strategy to reduce radon risks. It combines and reinforces EPA's basic foundation, including its guiding policies and cooperative partnerships, with an overall management approach and focus for the future. The paper starts with an overview that introduces the strategy's four key elements: underlying policies and scientific principles, a decentralized system of states and other partners for targeting the public, multiple strategies for achieving radon risk reduction, and a strong focus on five key program priorities. This paper then discusses each of these elements in more detail and describes how they interact to guide future efforts and directions of the Agency

  3. A summary of EPA radon chamber tests and results for rounds 3 and 4 of the National Radon Measurement Proficiency Program

    International Nuclear Information System (INIS)

    Smith, J.M.; Sensintaffar, E.L.

    1993-02-01

    The US Environmental Protection Agency's Office of Radiation and Indoor Air (ORIA) established the National Radon Measurement Proficiency (RMP) Program in 1986. Through this voluntary program, participants can demonstrate their ability to measure radon and/or radon decay products by submitting their detection devices to a blind test in a designated radon chamber. In this report, two EPA radon and radon decay products test chambers (chambers A and C) located at the National Air and Radiation Environmental Laboratory in Montgomery, Alabama are described. These chambers were used to expose detectors submitted for testing in Round 4 of the National Radon Measurement Proficiency Program and are used routinely for calibration purposes. Also described are the measurement and calibration procedures which were used to establish the official target values for radon and radon decay products concentrations during RMP Round 4 testing. The results for RMP Round 3 (conducted at the US DOE Environmental Measurements Laboratory radon chamber in New York) and RMP Round 4 (conducted in the two NAREL chambers) are discussed and compared. Following Round 4, the NAREL staff analyzed the collective performance for each measurement method tested in these rounds and found that all methods agreed with the target values within expected limits except for RPISU's and charcoal adsorbers. After analyzing the RMP4 results, NAREL staff spent several months evaluating the difference in charcoal adsorber response between Round 3 and 4 by performing radon chamber tests using EPA 4-inch, open-faced charcoal adsorbers

  4. National Radon Contractor Proficiency (RCP) Program. Proficiency report, June 1991

    International Nuclear Information System (INIS)

    1991-06-01

    The primary objective of the U.S. Environmental Protection Agency's (EPA) efforts to address the indoor radon problem is to reduce radon levels in buildings throughout the country. Achieving the objective requires a nationwide supply of capable radon mitigation contractors. In the Indoor Radon Abatement Act of 1988, Congress authorized EPA to establish a program to evaluate radon mitigation contractors and to provide the information to the public in cooperation with the States. The Radon Contractor Proficiency (RCP) Program was developed to assist States, EPA Regions, local government officials, and the public in selecting contractors who have demonstrated their proficiency in reducing indoor radon levels. The program is managed by the EPA Office of Radiation Programs' Radon Division. Under the voluntary program, radon contractors demonstrate their proficiency by meeting specific Program requirements. Individual contractors who meet these requirements are then listed in periodic RCP Proficiency Reports

  5. National Radon Contractor Proficiency (RCP) program. Proficiency report, September 1991

    International Nuclear Information System (INIS)

    1991-09-01

    The primary objective of the U.S. Environmental Protection Agency's (EPA) efforts to address the indoor radon problem is to reduce radon levels in buildings throughout the country. Achieving this objective requires a nationwide supply of capable radon mitigation contractors. In the Indoor Radon Abatement Act of 1988, Congress authorized EPA to establish a program to evaluate radon mitigation contractors and to provide this information to the public in cooperation with the States. The Radon Contractor Proficiency (RCP) Program was developed to assist States, EPA Regions, local government officials, and the public in selecting contractors who have demonstrated their proficiency in reducing indoor radon levels. The program is managed by the EPA Office of Radiation Programs' Radon Division. Under this voluntary program, radon contractors demonstrate their proficiency by meeting specific Program requirements. Individual contractors who meet these requirements are then listed in the Report

  6. National Radon Contractor Proficiency (RCP) Program. Proficiency report, January 1992

    International Nuclear Information System (INIS)

    1992-01-01

    The primary objective of the U.S. Environmental Protection Agency's (EPA) efforts to address the indoor radon problem is to reduce radon levels in buildings throughout the country. Achieving the objective requires a nationwide supply of capable radon mitigation contractors. In the Indoor Radon Abatement Act of 1988, Congress authorized EPA to establish a program to evaluate radon mitigation contractors and to provide the information to the public in cooperation with the States. The Radon Contractor Proficiency (RCP) Program was developed to assist States, EPA Regions, local government officials, and the public in selecting contractors who have demonstrated their proficiency in reducing indoor radon levels. The program is managed by the EPA Office of Radiation Programs' Radon Division. Under the voluntary program, radon contractors demonstrate their proficiency by meeting specific Program requirements. Individual contractors who meet these requirements are then listed in the Report

  7. National radon measurement-proficiency program: Individual proficiency report

    International Nuclear Information System (INIS)

    1992-05-01

    In February 1986, the U.S. Environmental Protection Agency (EPA) established the Radon Measurement Proficiency (RMP) Program to assist the public in identifying organizations capable of providing reliable radon measurement services. In December 1991, EPA announced the new individual proficiency listing category in the RMP Program. Individuals applying for this new listing status must demonstrate knowledge of radon measurement fundamentals by passing a written proficiency examination, maintain affiliation with an RMP listed organization, and meet other program requirements. This report lists those individuals who have met the requirements of the RMP Program as of April 30, 1992. These requirements are designed to provide minimum proficiency criteria for individuals who provide radon measurement services on-site in a residential environment

  8. Radon Measurement Proficiency (RMP) Program methods and devices

    International Nuclear Information System (INIS)

    Harrison, J.; Hoornbeek, J.; Jalbert, P.; Sensintaffar, E.; Hopper, R.

    1991-01-01

    The US EPA developed the voluntary Radon Measurement Proficiency Program in 1986 in response to a Federal and State need for measurement services firms to demonstrate their proficiency with radon measurement methods and devices. Since that time, the program has set basic standards for the radon measurement industry. The program has grown dramatically since its inception. In 1986, fewer than 50 companies participated in the program. By 1989, more than 5,000 companies were participating. Participants represent firms with an analytical capability as well as firms that rely upon another firm for analysis service. Since the beginning of the RMP Program, the Agency has learned a great deal about radon measurement methods and devices. This paper reviews the measurement devices used in the program and what the EPA has learned about them since the program's inception. Performance data from the RMP Program are used to highlight relevant findings

  9. Interactive house investigation and radon diagnostics computer program

    International Nuclear Information System (INIS)

    Gillette, L.M.

    1990-01-01

    This paper reports on the interactive computer program called Dungeons and Radon which was developed as part of the Environmental Protection Agency's (EPA's) Radon Contractor Proficiency (RCP) Program's Radon Technology for Mitigators (RTM) course which is currently being offered in the Regional Radon Training Centers (RRTCs). The program was designed by Terry Brennan to be used in training radon mitigation contractors. The Macintosh based program consists of a series of animated, sound and voice enhanced house scenes. The participants choose where and what to investigate and where to perform diagnostic tests in order to gather enough information to design a successful mitigation system

  10. EPA urges schools to check for radon

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    In April recommended that schools test their facilities for radioactive radon gas after examining preliminary test data from 130 schools scattered across the country which indicated that elevated radon levels may be at least as prevalent in schools as in private residences. EPA is recommending that schools test 100 percent of frequently-used rooms on the basement-level and ground-level floors. The agency also recommends that testing be conducted in the cooler months of the year when doors and windows are likely to be closed. As part of a study to gather more information about measuring radon in schools, EPA tested approximately 3000 classrooms in 16 states. The states are widely distributed across the country. Of the total number of rooms, 54 percent had at least one room with a radon level above four picocuries per liter of air pCi/L. Nineteen percent had radon levels above four pCi/L. Three percent of the classrooms measured had radon level over 20 pCi/L. Each of the 16 states had a school with one measurement over four pCi/L, and one school had levels as high as 136 pCi/L

  11. American Lung Association's radon public information program

    International Nuclear Information System (INIS)

    McCurdy, L.E.

    1992-01-01

    The American Lung Association (ALA), the nation's oldest voluntary health organization, is dedicated to the conquest of lung disease and the promotion of lung health. The objective of the ALA Radon Public Information Program is to reduce public exposure to elevated indoor radon levels through implementing grassroots-based radon public awareness campaigns by 22 local ALA groups. The program, which is funded by a grant from the US Environmental Protection Agency (EPA), was initiated in December 1989; the first phase will continue until May, 1991. Activities of local Lung Associations include distribution of free or reduced-cost radon kits; presenting programs in elementary and secondary schools; presenting information on TV news series and talk shows, and on radio Public Service Announcements and talk shows; presenting articles and feature stories in the print media; holding conferences, workshops, and displays at fairs and other exhibitions; distributing radon fact sheets through libraries and utility company mailings; and distributing videos through video chains and libraries. The local Lung Associations also serve as promoters for the EPA/Advertising Council Radon Public Service Announcement Campaign. We will highlight the activities of the groups in communicating radon health risks to the public; we will describe the results obtained and will attempt to evaluate the merits of the various approaches on the basis of the initial results

  12. The US radon problem, policy, program and industry: achievements, challenges and strategies

    International Nuclear Information System (INIS)

    Angell, W. J.

    2008-01-01

    US radon research, policy and programs have stalled since their start in the late 1980's and early 1990's. In 2005, more homes had radon above the US Environmental Protection Agency (EPA) Reference Level than anytime in history since more homes were added to the housing stock that had indoor radon concentrations exceeding 150 Bq m -3 than had been mitigated. Funding for the US radon program has declined two-thirds from 1997 to 2007. Despite impressive goals for radon reduction, EPA lacks sound progress indicators especially in new construction radon control systems. School radon reduction has been at a standstill since the early 1990's. There has been no significant radon risk reduction in low-income sectors of the population. There is need for effective partnerships between the public and private sectors of the US radon professional communities as well as with the international programs and professionals. (authors)

  13. EPA's radon study results

    International Nuclear Information System (INIS)

    Dowd, R.M.

    1988-01-01

    Last winter, in cooperation with agencies in 10 states and two metropolitan area counties, EPA measured the indoor air radon concentrations of 14,000 houses, some chosen statistically at random and some by request of the homeowner. Passive measurement methodologies were used, such as exposing a charcoal canister to the air for a few days and allowing the air to migrate in to the charcoal naturally. To reduce dilution of radon by the outside air, the protocol required that the house be shut up; therefore, the study was conducted during winter. The measuring device was placed in the lowest livable area (usually the basement) of each house to maximize potential concentration. It should be noted that these procedures are generally considered to be screening tests because they result in a worst-case measurement rather than a best value. The results of these findings are presented

  14. Lessons from radon

    International Nuclear Information System (INIS)

    Nichols, M.

    1993-01-01

    At EPA there is a public outreach program that the Office of Air and Radiation (OAR) has developed for radon. To meet the difficult challenge radon presented, OAR's Radon Division developed working relationships with national nonprofit groups who share a mission. These groups have well-established communication networks with their memberships for advancing their goals. Such diverse groups as the American Lung Association, the Advertising Council, the National Association of Counties (NACo), the Consumer Federation of America, the National Association of Homebuilders, and the National Safety Council have joined with EPA to reduce radon health risks. Through this alliance, EPA has been able to take advantage of communication channels that it could never replicate on tis own. Every group working with EPA disseminates the radon message through its own established channels to reach its constituency. These partners wield authority in their fields and are ideal for addressing the concerns of their audiences

  15. Managing Radon in Schools

    Science.gov (United States)

    EPA recommends testing all schools for radon. As part of an effective IAQ management program, schools can take simple steps to test for radon and reduce risks to occupants if high radon levels are found.

  16. Air pollution. Actions to promote radon testing

    International Nuclear Information System (INIS)

    Guerrero, Peter F.; Adams, Charles M.; McGee, William F.; Goldsmith, Larry A.; Feldesman, Alice G.; Grissinger, Charles R.; Updegraff, William D.; Langdon, Robin S.; Bartholomew, Philip L.

    1992-12-01

    To promote radon testing, EPA initiated public information and awareness programs and provided grants to states to develop programs aimed at encouraging homeowners to test for radon. Nationwide telephone surveys, according to EPA, indicate that these efforts have raised the public awareness of radon to as high as 78 percent but that about only 9 percent of those surveyed have tested their homes for radon. Concerned about improving risk reduction through its radon program, EPA convened a review panel. The panel not only recommended in May 1992 that the current voluntary approach be continued but also called for program changes to encourage more testing. These changes include targeting public information and other resources to areas where radon levels are predicted to be high and promoting testing and mitigation at the time of real estate transactions. To support state radon efforts, the Congress authorized a grant program for yearly grants of $10 million for 3 years. Funds for this program were recently extended for a fourth year through fiscal year 1993. Information to measure states' success in promoting testing by homeowners was generally not available because (1) much of the grant funding has been used to identify the extent of the radon problem; (2) federally funded public information projects were often directed to large audiences, making it difficult to measure testing rates; and (3) EPA's evaluation process for the grant program did not contain a component to measure increases in testing. We did, however, identify some state projects that have increased radon testing by targeting program efforts to homes in areas with potentially high levels of radon. The results of the state projects would seem to support the EPA review panel's recommendations on promoting radon testing through targeting program resources. In two states we surveyed, the voluntary use of disclosure statements as part of a real estate sales contract was a frequent occurrence, and in one state

  17. EPA program to demonstrate mitigation measures for indoor radon: initial results

    International Nuclear Information System (INIS)

    Henschel, D.B.; Scott, A.G.

    1986-01-01

    EPA has installed radon mitigation techniques in 18 concrete block basement homes in the Reading Prong region of eastern Pennsylvania. Three alternative active soil ventilation approaches were tested: suction on the void network within the concrete block basement walls; suction on the footing drain tile system; and suction on the aggregate underneath the concrete slab. The initial 18 mitigation installations were designed to demonstrate techniques which would have low to moderate installation and operating costs. Where effective closure of major openings in the block walls is possible, suction on the wall voids has proved to be extremely effective, able to reduce homes having very high radon Working Levels (up to 7 WL) to 0.02 WL and less. However, where inaccessible major openings are concealed within the wall, it is more difficult and/or more expensive to develop adequate suction on the void network, and performance is reduced. Testing is continuing to demonstrate the steps required to achieve high performance with wall suction in homes with such difficult-to close walls. Drain tile suction can be very effective where the drain tiles completely surround the home; drain tile suction is the least expensive and most aesthetic of the active soil ventilation approaches, but appears susceptible to spikes in radon levels when the basement is depressurized. Sub-slab suction as tested in this study - with one or two individual suction points in the slab - does not appear adequate to ensure sustained high levels of reduction on block wall basement homes; it appears to effectively treat slab-related soil gas entry routes so long as a uniform layer of aggregate is present, but it does not appear to effectively treat the wall-related entry routes. Closure of major openings might have improved sub-slab suction performance. 5 figures, 3 tables

  18. Radon Research Program, FY 1991

    International Nuclear Information System (INIS)

    1992-03-01

    The scientific information being sought in this program encompasses research designed to determine radon availability and transport outdoors, modeling transport into and within buildings, physics and chemistry of radon and radon progeny, dose response relationships, lung cancer risk, and mechanisms of radon carcinogenesis. The main goal of the DOE/OHER Radon Research Program is to develop information to reduce these uncertainties and thereby provide an improved health risk estimate of exposure to radon and its progeny as well as to provide information useful in radon control strategies. Results generated under the Program were highlighted in a National Research Council report on radon dosimetry. The study concluded that the risk of radon exposure is 30% less in homes than in mines. This program summary of book describes the OHER FY-1991 Radon Research Program. It is the fifth in an annual series of program books designed to provide scientific and research information to the public and to other government agencies on the DOE Radon Research Program

  19. SUMMARY OF EPA'S RADON REDUCTION RESEARCH IN SCHOOLS DURING 1989-90

    Science.gov (United States)

    The report details radon mitigation research in schools conducted by EPA during 1989 and part of 1990. The major objective was to evaluate the potential of active subslab depressurization (ASD) in various geologic and climatic regions. The different geographic regions also pres...

  20. Summary of EPA's radon-reduction research in schools during 1989-90

    International Nuclear Information System (INIS)

    Leovic, K.W.

    1990-10-01

    The report details radon mitigation research in schools conducted by EPA during 1989 and part of 1990. The major objective was to evaluate the potential of active subslab depressurization (ASD) in various geologic and climatic regions. The different geographic regions also presented a variety of construction types and heating, ventilating, and air-conditioning (HVAC) system designs that are encountered in radon mitigation of school buildings. A secondary objective was to initiate research in difficult-to-mitigate schools. The research led to the following major conclusions on radon diagnostics and mitigation in schools: (1) Schools have many physical characteristics that typically make their mitigation more complex than house mitigation, including building size and substructure, subslab barriers, HVAC systems, and locations of utility lines. (2) Important school diagnostic procedures and measurements include review of radon measurements and building plans, investigation of the building to assess potential radon entry routes and confirm information in the building plans, analysis of the HVAC system and its influence on pressure differentials and radon levels, and subslab pressure field extension measurements to determine the potential applicability of ASD. (3) ASD can be applied successfully in schools where subslab communication barriers are limited

  1. Radon Research Program, FY-1990

    International Nuclear Information System (INIS)

    1991-03-01

    The Department of Energy (DOE) Office of Health and Environmental Research (OHER) has established a Radon Research Program with the primary objectives of acquiring knowledge necessary to improve estimates of health risks associated with radon exposure and also to improve radon control. Through the Radon Research Program, OHER supports and coordinates the research activities of investigators at facilities all across the nation. From this research, significant advances are being made in our understanding of the health effects of radon. OHER publishes this annual report to provide information to interested researchers and the public about its research activities. This edition of the report summarizes the activities of program researchers during FY90. Chapter 2 of this report describes how risks associated with radon exposure are estimated, what assumptions are made in estimating radon risks for the general public, and how the uncertainties in these assumptions affect the risk estimates. Chapter 3 examines how OHER, through the Radon Research Program, is working to gather information for reducing the uncertainties and improving the risk estimates. Chapter 4 highlights some of the major findings of investigators participating in the Radon Research Program in the past year. And, finally, Chapter 5 discusses the direction in which the program is headed in the future. 20 figs

  2. Navy Radon Assessment and Mitigation Program: Work/quality assurance project plan screening phase

    International Nuclear Information System (INIS)

    1991-03-01

    In 1987, the military services of the United States were tasked to take appropriate action to establish an indoor radon assessment and mitigation program. As a result, the Naval Facilities Engineering Command (NAVFACENGCOM) was assigned the responsibility of identifying potential hazards to personnel from exposure to naturally occurring radon gas and prioritizing corrective actions and to coordinating these actions with the major claimants. NAVRAMP is based upon current US Environmental Protection Agency (EPA) guidelines. The program has been separated into four phases. The screening phase will concentrate on evaluating radon levels, based on statistical samples, in those buildings that have been determined to be at most at risk to elevated levels of radon, such as base housing, schools, day-care centers, hospitals, brigs, Base Officer Quarters, and Base Enlisted Quarters. During the assessment phase, every building that contains personnel for over 4 h/day will be evaluated. Mitigation work will be accomplished by Navy or Navy-contracted personnel. HAZWRAP services during the mitigation phase will consist of determining the extent of reduction in radon levels after the mitigation effort. 7 refs., 11 figs

  3. The USGS/EPA ''radon potential of the U.S.'' project: A case study in the application of geoscience information to public policy

    International Nuclear Information System (INIS)

    Schumann, R.R.; Gundersen, L.C.S.

    1993-01-01

    As part of an interagency agreement with the US Environmental Protection Agency (EPA), the US Geological Survey (USGS) has prepared a series of maps and reports, by state, describing and assessing the geologic radon potential of the United States. The documents were prepared with multiple uses in mind, including guidance for targeted radon sampling or information programs, to aid in the application of radon-resistant building codes, and as a starting point for more detailed investigations. The USGS and EPA were assisted in the planning and review stages by the Association of American State Geologists, and the draft reports were also reviewed by the state radon contact agencies (typically health departments or departments of environmental protection) and other state and federal agencies. A relative radon potential ranking scheme was developed by USGS to provide consistency and accountability. The scheme consists of a Radon Index, the sum of 5 individually-scored factors (geology, soil permeability, aerial radioactivity, architecture, and screening indoor radon data), and an associated Confidence Index, an expression of the quality and quantity of the data used to evaluate each factor. The assessments are presented on a scale that is useful for state- or regional-scale planning, but inapplicable to areas smaller than counties. The most common problems cited by the reviewers are: (1) the conflict of natural geologic boundaries and political boundaries; (2) the use of the NURE aerial radiometric data; (3) the use of short-term charcoal canister data as opposed to long-term annual average data; (4) the definition of ''high'' radon and the cost of dealing with the radon problem if ''high'' is 4 pCi/L; and (5) the potential misuse of geologic assessments by the public, the radon industry, and governments. The use of geological common sense in concert with policy decisions can alleviate many of the above problems

  4. Radon Research Program, FY 1992

    International Nuclear Information System (INIS)

    1993-04-01

    The United States Department of Energy, Office of Health and Environmental Research (DOE/OHER) is the principal federal agency conducting basic research related to indoor radon. The scientific information being sought in this program encompasses research designed to determine radon availability and transport outdoors, modeling transport into and within buildings, physics and chemistry of radon and radon progeny, dose response relationships, lung cancer risk, and mechanisms of radon carcinogenesis. There still remains a significant number of uncertainties in the currently available knowledge that is used to estimate lung cancer risk from exposure to environmental levels of radon and its progeny. The main goal of the DOE/OHER Radon Research Program is to develop information to reduce these uncertainties and thereby provide an improved health risk estimate of exposure to radon and its progeny and to identify and understand biological mechanisms of lung cancer development and required copollutants at low levels of exposure. Information useful in radon control strategies is also provided by the basic science undertaken in this program

  5. S. 2844: A Bill to provide for radon testing. Introduced in the Senate of the United States, One Hundredth Congress, Second Session, September 29, 1988

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This bill, entitled as the Department of Housing and Urban Development Radon Policy Act, has been introduced to provide for radon testing. The purposes of this Act are to: provide the Department of Housing and Urban Development with a mandate to establish a departmental radon policy and program; require the Department of Housing and Urban Development to use its programs to assist the EPA in addressing radon contamination; and require the Department of Housing and Urban Development, in coordination with the EPA, to develop a radon assessment and mitigation program which utilized EPA recommended guidelines and standards to ensure that occupants of housing covered under this Act are not exposed to elevated levels of radon

  6. Element of risk: The politics of radon

    International Nuclear Information System (INIS)

    Cole, L.A.

    1994-01-01

    The recent history of the Environmental Protection Agency's (EPA) approach to managing the risk of indoor radon offers a rich base from which to consider US practice in risk assessment, management, and communication. The biological evidence of risks from high-level exposure to radon is in many ways stronger--and the gap to be spanned by extrapolation from laboratory animal studies to ambient exposures narrower--than for many of the toxic and hazardous air pollutants that have been the focus of EPA regulatory attention. The epidemiological evidence about radon is complicated by a number of confounding variables, but this is often the state of epidemiological evidence. Radon has also been the focus of a considerable amount of research on risk communication. To complete the promising ingredients, disagreements between federal regulators at EPA and managers of federal nuclear programs run by the Department of Energy (DOE) concerning radon from uranium mill tailings, for example, and other issues in radiation health physics offer a rich array of opportunities to explore issues in federal bureaucratic politics. This book provides a straightforward report of much of the development of US policy on indoor radon over the past decade. As such, it gives readers unfamiliar with the evolution of radon regulation an opportunity to come quickly up to speed on many historical details

  7. EPA (Environmental Protection Agency) Indoor-Air Quality Implementation Plan. A report to Congress under Title IV of the Superfund Amendments and Reauthorization Act of 1986: radon gas and indoor air-quality research. Final report

    International Nuclear Information System (INIS)

    1987-06-01

    The EPA Indoor Air Quality Implementation Plan provides information on the direction of EPA's indoor air program, including the Agency's policy on indoor air and priorities for research and information dissemination over the next two years. EPA submitted the report to Congress on July 2, 1987 as required by the Superfund Amendments and Reauthorization Act of 1986. There are five appendices to the report: Appendix A--Preliminary Indoor Air Pollution Information Assessment; Appendix B--FY 87 Indoor Air Research Program; Appendix C--EPA Radon Program; Appendix D--Indoor Air Resource History (Published with Appendix C); Appendix E--Indoor Air Reference Data Base

  8. The radon service industry in selected Northeastern states

    International Nuclear Information System (INIS)

    Watson, M.R.; Reese, J.P.; Adams, A.R.

    1988-01-01

    In 1986 the EPA initiated an expedited program of technical assistance in response to the discovery of extremely elevated levels of indoor radon in Pennsylvania homes. A vital component of this project was a training program which addressed the variety of techniques used to reduce human exposure to radon gas and its decay products. The New York State Energy Office was selected as the most suitable organization to assist in this project because of its relevant experience in training programs, especially the building for energy efficiency workshop series with its indoor radon gas component. This paper reports on the project

  9. Mineral dusts and radon in uranium mines

    International Nuclear Information System (INIS)

    Abelson, P.H.

    1991-01-01

    The Environmental Protection Agency (EPA) continues to assert that radon is a major cause of lung cancer in this country. EPA is fostering a radon program that could entail huge financial and emotional costs while yielding negligible benefits to public health. Justification for the program was the occurrence of lung cancer in men exposed to huge amounts of radon, mineral dusts, and other lung irritants in uranium mines on the Colorado Plateau. Lung cancer has been reported in about 356 cigarette smokers and in about 25 nonsmokers. During the era of high radon levels, monitoring was sporadic. Conditions in only a small fraction of the mines were measured, and that on a few separate occasions. Later, cumulative exposure to radon was calculated on the basis of measurements involving only a tiny fraction of the miners. Some were exposed to more than 15,000 pCi/liter of radon and its products. The level in the average home is about 1.5 pCi/liter. In making extrapolations from mine to home, the assumption is made that residents are in their dwellings most of the time and that miners spend only 170 hours a month in the mine. Two major questionable assumptions are involved in extrapolations from high doses of radon in the mines to low doses in homes. One is that no threshold is involved; that is, that humans have no remediation mechanism for α particle damages. There is evidence to the contrary. The most unrealistic assumption is that heavy exposure to silica has no effect on inducing lung cancer. Many studies have shown that silica dust causes lung cancer in animals. Exposure of human culture cells to silica has resulted in formation of neoplastic tissue. EPA has no solid evidence that exposures to 4 pCi/liter of radon causes lung cancer in either smokers or nonsmokers. Indeed, there is abundant evidence to the contrary in the fact that in states with high levels of radon, inhabitants have less lung cancer than those in states with low levels

  10. Radon reduction and radon-resistant construction demonstrations in New York state. Final report

    International Nuclear Information System (INIS)

    1991-02-01

    A survey of radon levels in New York State homes indicates that approximately 4.4 percent of the homes have long-term living area radon concentrations above the U.S. EPA guideline of four pCi/l. The project addressed the effectiveness of techniques to reduce the radon level in existing homes and to prevent the occurrence of high radon concentrations in new homes. The goal of the project was to demonstrate the effectiveness of radon reduction techniques in homes containing indoor radon concentrations of more than the current EPA guidelines of four pCi/l. At the same time, radon-resistant construction techniques were demonstrated in homes under construction to provide guidelines for houses being built in areas with a danger of high radon levels. The project demonstrated new radon mitigation techniques in homes containing indoor radon concentrations exceeding four pCi/l; assessed the value of previously installed radon reduction procedures, and demonstrated new radon-resistant construction methods

  11. S. 2844: A Bill to provide for radon testing. Introduced in the Senate of the United States, One Hundredth Congress, Second Session, September 29, 1988

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    Bill S. 2844 provides for radon testing and is cited as the Department of Housing and Urban Development Policy Act. The bill provides the Department of Housing and Urban Development (HUD) with a mandate to establish a departmental radon policy and program. The department will be required to use its programs to assist the Environmental Protection Agency (EPA) address radon contamination. The bill also requires HUD, in coordination with the EPA, to develop a radon assessment and mitigation program which utilizes EPA recommended guidelines and standards to ensure that occupants of housing covered under this act are not exposed to elevated levels of radon. The entire contents of the bill are presented in eight sections entitled: Short Title, findings, Purpose, Definitions, Program, Information, Cooperation with Environmental Protection Agency, and Authorization. The bill was referred to the Committee on Banking, Housing and Urban Affairs

  12. Modeling the potential impacts of different radon policies for the U.S. housing stock

    International Nuclear Information System (INIS)

    Peterson, M.D.; Ritchie, I.M.

    1995-01-01

    According to the Environmental Protection Agency (EPA) and other public health agencies in the United States, radon may be the leading cause (along with passive smoking) of lung cancer deaths among nonsmokers. Radon is estimated to be the second leading cause of lung cancer death in smokers behind smoking-related lung cancer. EPA estimates that 7,000 to 30,000 lung cancer deaths each year are due to radon exposure. (It is implied that radon-related lung cancer deaths can be prevented by reducing radon levels below EPA's guideline levels). Current EPA radon policy is based on a strategy of education, the transfer of testing and remediation technologies to the public and private sectors, and recently proposed radon-resistant construction standards for new homes. This paper models the effectiveness of current proposed, and alternative policies for reducing radon risks in U.S. residential construction. The results of our analysis suggest that EPS's projections of 2,200 'lives saved annually' as a result of its current action level of 4 pCi/l will not be achieved with its current policy in the near future. Overall, the response of radon-related mortality to most policy options is delayed and flat due in part to the large number of houses with low radon levels and the long latency period between radon exposure and the development of cancer. The modeling results suggest that more aggressive smoking reduction programs may yield greater benefits in overall lung cancer mortality (but not reduced radon exposure) than most radon-related policies. (au)

  13. The HAZWRAP/Navy Radon Project

    International Nuclear Information System (INIS)

    Otten, J.A.; Wilson, D.L.

    1992-01-01

    In 1987, the Naval Facilities Engineering Command (NAVFACENGCOM) was assigned the responsibility of identifying potential hazards from exposure to naturally occurring indoor radon to personnel in Naval facilities and prioritizing corrective actions. In response to this request, NAVFACENGCOM established the Navy Radon Assessment and Mitigation Program (NAVRAMP), which evaluates problems associated with radon levels above current Environmental Protection Agency (EPA)-guidelines (EPA-520/1-86-04) of 4pCi/L. NAVRAMP consists of four phases: screening, assessment, mitigation, and postmitigation. Approximately 300,000 alpha track detectors (ATDs) will be used during the screening and assessment phases. Several unique approaches were developed to verify the quality of the information collected during this large program. To guarantee chain-of-custody, a computerized data management system was developed to track each ATD from initial purchase through field implementation to final analysis and was also used to track and identify quality control (QC) problems related to the manufacture and analysis of ATDs. The QC program addressed potential problems that could occur using ATDs. The potential errors associated with the use of ATDs included (1) lot-to-lot variation, (2) chemical process variation, (3) pouch leakage, and (4) background. The data management and QC programs ensured the quality and integrity of the samples, the accuracy and precision of the analyses, the representatives of the results, and the completeness of the information

  14. From insulation contracting to radon mitigation

    International Nuclear Information System (INIS)

    West, D.R.

    1990-01-01

    As the definition of house doctor has evolved over the past ten years and the field of energy services has grown more sophisticated, many contractors have expanded the services they offer their clients. This paper presents the story of one insulation contractor who has found a niche in radon testing and mitigation. The EPA now has a national program for the radon mitigator called the Radon Contractor Proficiency Program. The requirements include attending the Radon Technology for Mitigators course, passing an exam, and taking continuing education. In the Midwest, the most popular mitigation technique is the subslab depressurization system. To draw suction from under the slab, the system can take advantage of an existing sump crock or can penetrate the slab. Interior drain tiles collect water to empty into the crock, providing an excellent pathway to draw from. This mitigation process is explained

  15. Uncertainties of estimating average radon and radon decay product concentrations in occupied houses

    International Nuclear Information System (INIS)

    Ronca-Battista, M.; Magno, P.; Windham, S.

    1986-01-01

    Radon and radon decay product measurements made in up to 68 Butte, Montana homes over a period of 18 months were used to estimate the uncertainty in estimating long-term average radon and radon decay product concentrations from a short-term measurement. This analysis was performed in support of the development of radon and radon decay product measurement protocols by the Environmental Protection Agency (EPA). The results of six measurement methods were analyzed: continuous radon and working level monitors, radon progeny integrating sampling units, alpha-track detectors, and grab radon and radon decay product techniques. Uncertainties were found to decrease with increasing sampling time and to be smaller when measurements were conducted during the winter months. In general, radon measurements had a smaller uncertainty than radon decay product measurements. As a result of this analysis, the EPA measurements protocols specify that all measurements be made under closed-house (winter) conditions, and that sampling times of at least a 24 hour period be used when the measurement will be the basis for a decision about remedial action or long-term health risks. 13 references, 3 tables

  16. Community-based radon education programs

    International Nuclear Information System (INIS)

    Laquatra, J.

    1990-01-01

    This paper reports that in the United States, educational programs about radon gas have been developed and implemented by federal and state government entities and other organizations, including the Cooperative Extension Service and affiliated land grant universities. Approaches have included the production of brochures, pamphlets, workshops for targeted audiences, and consumer telephone hotlines. In a free market for radon mitigation products and services, these efforts can be appropriate for their credibility, lack of bias, and individualized approaches. The purpose of this paper is to report on an educational program about radon undertaken by Cornell Cooperative Extension, including county-based workshops targeted to homeowners, housing professionals, high school teachers, and others. An analysis of survey data from program participants forms the basis for a discussion of the effectiveness of the Cooperative Extension Service in reaching the public about this topic

  17. Screening radon risks: A methodology for policymakers

    International Nuclear Information System (INIS)

    Eisinger, D.S.; Simmons, R.A.; Lammering, M.; Sotiros, R.

    1991-01-01

    This paper provides an easy-to-use screening methodology to estimate potential excess lifetime lung cancer risk resulting from indoor radon exposure. The methodology was developed under U.S. EPA Office of Policy, Planning, and Evaluation sponsorship of the agency's Integrated Environmental Management Projects (IEMP) and State/Regional Comparative Risk Projects. These projects help policymakers understand and use scientific data to develop environmental problem-solving strategies. This research presents the risk assessment methodology, discusses its basis, and identifies appropriate applications. The paper also identifies assumptions built into the methodology and qualitatively addresses methodological uncertainties, the direction in which these uncertainties could bias analyses, and their relative importance. The methodology draws from several sources, including risk assessment formulations developed by the U.S. EPA's Office of Radiation Programs, the EPA's Integrated Environmental Management Project (Denver), the International Commission on Radiological Protection, and the National Institute for Occupational Safety and Health. When constructed as a spreadsheet program, the methodology easily facilitates analyses and sensitivity studies (the paper includes several sensitivity study options). The methodology will be most helpful to those who need to make decisions concerning radon testing, public education, and exposure prevention and mitigation programs.26 references

  18. Radon risks: Attitudes, perceptions and actions. Risk communication series. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Sjoeberg, L.

    1989-08-01

    As many as 8 million homes in the United States may have elevated radon levels, with accompanying lung cancer risks several orders of magnitude higher than for most other environmental risks. The U.S. Environmental Protection Program (EPA) does not have clear regulatory authority over radon, so has relied on an information program. Less than 5% of homes have been tested, which is disappointing from a public health stance. The report summarizes the available research on communicating about the risk from radon from the perspective of a psychologist. The research results are critiqued to draw practical conclusions for radon policy and suggest the most important topics for further risk communication research.

  19. A Risk Management Strategy for Radon: The US Experience (invited paper)

    International Nuclear Information System (INIS)

    Boschi, N.

    1998-01-01

    In the United States (US) the Environmental Protection Agency (EPA or Agency) has played a leading role on radon policy. EPA estimates that indoor radon in the US causes approximately 14,000 lung cancer deaths per year with an uncertainty range of 7,000 to 30,000. In 1988, EPA and the Center for Disease Control issued an advisory urging that most houses in the US be tested for radon. The risk assessments have indicated a problem of substantial magnitude. Nonetheless, risk of radon has been assumed to follow a non-threshold model and risk management strategies have been based on the concept that exposures at levels ≥148 Bq.m -3 (4 pCi.1 -1 ). EPA's approach has been to call for voluntary testing, since the Agency does not have direct regulatory authority, and to follow an action guideline of 148 Bq.m -3 . This paper provides an overview of EPA's risk management strategy to control exposure to indoor radon. The first part reviews EPA's approach to radon testing and radon measurement protocols while introducing the option of encouraging homes to be tested and, if necessary, mitigated at the time of any real estate transaction. The second part introduces EPA's voluntary guidelines for construction techniques on how to minimise radon in new homes and addresses how these guidelines could be adopted by the States, local governments, and private sector homebuilders. The third part presents EPA's programme to educate the public on indoor radon risk. The paper concludes by outlining a Congressional directed approach to radon protection based on a multi-media risk management model for radon in air and water. (author)

  20. Radon, a real threat to our health

    International Nuclear Information System (INIS)

    Mauna, T.; Mauna, A.; Ghita, R.

    2005-01-01

    Radon is invisible, odorless and tasteless a radioactive gas that comes from the radioactive decay of naturally occurring uranium and thorium in soil and rock, can concentrate in domestic homes, overground workplaces, and caves. Radon has been identified as the second leading cause of lung cancers in the U.S., about 20.000 per year, and is present in millions of homes. The Environmental Protection Agency (EPA) of USA designated January 2005 as National Radon Action Month (NRAM) and held the second week of October every year as National Radon Action Week (NRAW). The focus of NRAM and NRW is to promote awareness about, testing for and mitigation of indoor radon gas with various events and outreach campaigns. The EPA considering radon exposure as capital problem for the population health decided to have a special dedicated free phone number the similar for every county state of USA taking into account the increase easy call by interested people. Many universities and research centers, including NGO from different countries world wide, following the recommendation of 'United Nations Scientific Committee on the Effects of Atomic Radiation' (USNCEAR) and 'International Commission on Radiological Protection ' (ICRP) until 1977, developed their own radon researches in order to clarify the properties, area distribution and concentration, geological production and other needed aspects. This paper compare the radon risk versus radioactive waste gaseous Nuclear Power Plant release in normal or abnormal operation and underlines the needs for Romanian's radiation research laboratories to undertake radon protection programs similar to to those underway in other countries. (authors)

  1. Ground-truthing predicted indoor radon concentrations by using soil-gas radon measurements

    International Nuclear Information System (INIS)

    Reimer, G.M.

    2001-01-01

    Predicting indoor radon potential has gained in importance even as the national radon programs began to wane. A cooperative study to produce radon potential maps was conducted by the Environmental Protection Agency (EPA), U.S. Geological Survey (USGS), Department of Energy (DOE), and Lawrence Berkeley Laboratory (LBL) with the latter taking the lead role. A county-wide predictive model based dominantly on the National Uranium Resource Evaluation (NURE) aerorad data and secondly on geology, both small-scale data bases was developed. However, that model breaks down in counties of complex geology and does not provide a means to evaluate the potential of an individual home or building site. Soil-gas radon measurements on a large scale are currently shown to provide information for estimating radon potential at individual sites sort out the complex geology so that the small-scale prediction index can be validated. An example from Frederick County, Maryland indicates a positive correlation between indoor measurements and soil-gas data. The method does not rely on a single measurement, but a series that incorporate seasonal and meteorological considerations. (author)

  2. Ten practical lessons for an effective radon risk communication program

    International Nuclear Information System (INIS)

    Fisher, A.; Johnson, F.R.

    1990-01-01

    Those responsible for state and local radon programs often express frustration about the small share of homes that have been tested for radon, and the small share of those with high readings that have been mitigated. Several recent studies have examined how well alternative ways of communicating about radon's risk have accomplished the goals of motivating appropriate testing and mitigation. Unfortunately, the results of these studies have not reached practitioners. This paper is for them. It summarizes the practical implications that are most crucial for planning and implementing an effective radon risk communication program--a program that will motivate people to test for radon and mitigate when radon levels are high, without unduly alarming those whose radon levels are low

  3. Radon contamination problems in North Dakota. Hearing before the Committee on Environment and Public Works, United States Senate, One Hundredth Congress, First Session, August 20, 1987

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    From tests of 200 homes in North Dakota in over 25 cities and towns, the Department of Health estimates that as many as 50% of all homes in the state may have radon levels above the EPA-recommended safety level, at this hearing in Fargo, ten witnesses included university professors, state and local health authorities, and the North Dakota Association of Realtors. US Sen. Quentin N. Burdick of North Dakota, who chaired the hearing, pointed out that the recently passed Radon Program Development Act (1) provide seed money to help states get radon programs up and running; (2) requires EPA to conduct surveys in Federal buildings; and (3) requires EPA to determine the extent of radon contamination in the Nation's schools. He recommends that North Dakota take advantage of this Federal assistance

  4. Real estate transaction radon test tampering

    International Nuclear Information System (INIS)

    Ritter, D.L.

    1990-01-01

    A thousand-house study, over the past two years showed 35% of the houses were tampered with. This paper offers statistical charts representing the different methods of tampering; A slide presentation showing houses and the non-tamper controls used to monitor EPA closed-house conditions, movement of detectors and covering of detectors. A strong message must be conveyed now, that tampering will not be tolerated by radon technicians, when performing radon tests in the field. A message that incorporates non-tamper controls that are cost effective and provide for reasonably priced testing; A message that will lend credibility to our Radon industry by means of separating the professional test from a do-it-yourself homeowner test. This paper will address that message and offer a program for the prevention of tampering in a house during a PROFESSIONALLY done Radon test

  5. The role of the ventilation industry in addressing indoor radon

    International Nuclear Information System (INIS)

    Wellford, B.W.

    1988-01-01

    It is generally acknowledged that radon mitigation can only be accomplished on a national scale through a cooperative effort of government, industry and an informed public. The Environmental Protection Agency has developed, demonstrated and published acceptable procedures for testing and preventing the entry or radon into occupancies, as well as procedures for removal when it is not possible or economically viable to prevent radon from entering these occupancies. Various states have instituted programs for industry implementation of EPA procedures and public education programs are now underway. Industry effort will be required to mitigate existing housing stock, to insure new radon resistant housing and, equally important, to provide for radon monitoring and servicing of mitigation measures for centuries to come. What the nature of that industry can and should be and how government agencies can encourage the development of such industry is the subject of this paper

  6. Radon mitigation in schools

    International Nuclear Information System (INIS)

    Saum, D.; Craig, A.B.; Leovic, K.

    1990-01-01

    Since 1987, more than 40 schools in Maryland, Virginia, Tennessee and North Carolina were visited by the U.S. Environmental Protection Agency (EPA). School characteristics that potentially influence radon entry and impact mitigation system design and performance were identified. Mitigation systems that had proven successful in house mitigation were then installed in several of these schools. Many of the systems were installed by school personnel with some assistance from EPA and an experienced radon diagnostician. This article presents the diagnostic measurements made in the schools and it discusses in detail the specific mitigation systems that were installed in four Maryland schools by the EPA

  7. Nuclear tracks in solids and gas radon measurements

    International Nuclear Information System (INIS)

    Espinosa, G.

    2007-01-01

    Full text: The Department of Energy (DOE), the Environmental Protection Agency (EPA) in USA, and the European Community, have dedicated significant budget to the Radon study, its health effects and remedial actions for controlling and achieving lower levels, in these cases, nationwide research programs have been organized. With the aim to contribute on the radon levels knowledge in our country, the Applied Dosimetry Project at the Physics Institute of the University of Mexico has developed an indoor and outdoor radon measurement methodology. In this paper a passive radon detector device based on CR-39 polycarbonate for use in radon research and routine measurements is presented. As well the methodology for the track formation, automatic reading system, calibration procedure and measurements in a different location, are shown in this work. The results had been compared with dynamic detection systems, and another methodologies and research groups in order to have a high confidence in the radon levels reported. (Author)

  8. National Radon Contractor Proficiency Program. Proficiency report, October 1990

    International Nuclear Information System (INIS)

    1990-10-01

    The report lists those individual contractors in the United States who have met the requirements of the Radon Contractor Proficiency (RCP) Program as of August 18, 1990. These requirements are designed to provide minimum proficiency criteria for individuals who design and supervise the installation of radon mitigation systems in buildings. (Some States have more stringent requirements as part of their radon certification programs. The States should be consulted directly for details on their programs; see Section 5 for a list of State radon contacts). The RCP Program measures the proficiency of an individual contractor, not their company. Therefore, users of the report who select a mitigation firm should ensure that the services are provided by the listed contractor. The National RCP Program does not accredit mitigation contractors, nor does it certify, recommend, or endorse participating companies. Only the listed contractor, not their company of affilation, are deemed proficient. The inclusion of a contractor in the report should not be interpreted as a certification or accreditation of the individual or affiliated company

  9. Radon Pollution Control Act of 1987. Hearing before the Subcommittee on Transportation, Tourism, and Hazardous Materials of the Committee on Energy and Commerce, House of Representatives, One Hundredth Congress, First Session, April 23, 1987

    Energy Technology Data Exchange (ETDEWEB)

    1987-01-01

    Ten witnesses from the Environmental Protection Agency (EPA), state and local environmental agencies, teachers, health providers, and others testified on the risks and possible control measures of radon gas emissions in homes. Home tests are finding as many as 40% to have unacceptable levels, but EPA and other government agencies have waited for the media to alert the population. The witnesses were asked to suggest ways in which EPA can initiate assistance in this area in order to protect public health. EPA spokesmen reviewed their programs, including the Radon Action Program, which began operating in 1985. Material submitted for the record by EPA follows the testimony.

  10. Communicating radon risk effectively: a mid-course evaluation. Interim report

    International Nuclear Information System (INIS)

    Smith, V.K.; Desvousges, W.H.; Fisher, A.; Johnson, F.R.

    1987-07-01

    A panel of 2300 homeowners was divided into subgroups to test the effectiveness of six alternative ways of explaining the risk from naturally occurring radon gas. The research design focused on two dimensions: qualitative vs. quantitative and directive vs. evaluative. These characteristics led to 4 experimental booklets, which were compared with EPA's Citizen's Guide and a one-page fact sheet. The evaluation examined how much people learned about radon; whether they could form risk perceptions consistent with their home's measured radon level; and whether they felt they had enough information to make a decision about mitigation. The fact sheet did not perform well on any of these evaluation criteria. None of the five booklets clearly was best for all 3 evaluation criteria; the report discusses the implications for designing an effective radon-risk communication program

  11. Residential radon in Kansas City-black shales aren't the prime suspect

    International Nuclear Information System (INIS)

    Spencer, C.G.

    1993-01-01

    The US EPA preliminary assessment of potential radon risk (EPA, 1986) depicted a large area of the mid-continent in which radon levels might be elevated due to the presence of uranium-rich black shales. A preliminary study (Hilpman, Coveney ampersand Spencer, 1988) indicated that a significant percentage of homes in the greater Kansas City area had radon screening levels above 4 pCi/L. However, their lab tests with crushed black shale, and radon tests in limestone mines with black shale floors showed that the shale did not yield extremely high radon levels. This expanded study presents additional results of screening tests in homes, and correlates those results to bedrock geology and soil type. High radon levels in the Kansas city area are not due primarily to black shale sources. The highest readings are associated with limestone and non-organic shale. Mean radon level is higher in younger cyclothemic deposits, and a loessial soil. The EPA initial assessment overstated the radon risk attributable to black uraniferous shale sources. Assessment of the overall potential risk for the greater Kansas City area requires further evaluation of other sources

  12. Measuring radon in the workplace

    International Nuclear Information System (INIS)

    Boyd, M.

    1990-01-01

    The Environmental Protection Agency (EPA) has issued guidance for testing for radon in homes and interim guidance for testing in schools. Information on testing for radon in the workplace is the next initiative and this paper describes the current status of this effort. The results of measurements made in several buildings in the Washington, DC area are discussed. In this paper a discussion of preliminary guidance on radon survey design that has been offered to Federal agencies is presented

  13. Continuous, environmental radon monitoring program at the Yucca Mountain Site Characterization Project

    International Nuclear Information System (INIS)

    Liu, N.; Sorensen, C.D.; Tung, C.H.; Orchard, C.R.

    1995-01-01

    A continuous, environmental radon monitoring program has been established in support of the Department of Energy's (DOE) Yucca Mountain Site Characterization Project (YMP). The monitoring program is to characterize the natural radon emissions at the YMP site, to understand the existing radon concentrations in the environmental background, and to assess and control the potential work exposure. Based upon a study of the monitoring results, this paper presents a preliminary understanding of the magnitudes, characteristics, and exposure levels of radon at the YMP site

  14. Radon diagnostics and mitigation in two public schools in Nashville, Tennessee

    International Nuclear Information System (INIS)

    Craig, A.B.; Leovic, K.W.; Harris, D.B.

    1990-01-01

    This paper reports on diagnostic measurements and mitigation studies that were carried out in two schools in Nashville, Tennessee, as part of the Environmental Protection Agency's (EPAs) School Radon Mitigation Development/Demonstration Program. Diagnostic studies included architectural plans and building examination, sub-slab radon concentrations, sub-slab communications measurements, and detailed classroom radon measurements using 2-day charcoal canisters, electret ion chambers, and continuous monitors. Although sub-slab communications varied significantly between the two schools, both were amenable to mitigation using sub-slab suction. Average premitigation levels of 39.5 and 29.7 picocuries per liter (pCi/L) were reduced to 0.78 and 1.7 pCi/L in the two schools

  15. Quality assurance for radon exposure chambers at the National Air and Radiation Environmental Laboratory, Montgomery, Alabama

    Energy Technology Data Exchange (ETDEWEB)

    Semler, M.O.; Sensintaffar, E.L. [National Air and Radiation Environmental Laboratory, Montgomery, AL (United States)

    1993-12-31

    The Office of Radiation and Indoor Air, U.S. Environmental Protection Agency (EPA), operates six radon exposure chambers in its two laboratories, the National Air and Radiation Environmental Laboratory (NAREL) in Montgomery, Alabama, and the Las Vegas Facility, Las Vegas, Nevada. These radon exposure chambers are used to calibrate and test portable radon measuring instruments, test commercial suppliers of radon measurement services through the Radon Measurement Proficiency Program, and expose passive measurement devices to known radon concentrations as part of a quality assurance plan for federal and state studies measuring indoor radon concentrations. Both laboratories participate in national and international intercomparisons for the measurement of radon and are presently working with the National Institute of Standards and Technology (NIST) to receive a certificate of traceability for radon measurements. NAREL has developed an estimate of the total error in its calibration of each chamber`s continuous monitors as part of an internal quality assurance program. This paper discusses the continuous monitors and their calibration for the three chambers located in Montgomery, Alabama, as well as the results of the authors intercomparisons and total error analysis.

  16. Radon barrier field-test monitoring at Grand Junction tailings pile

    International Nuclear Information System (INIS)

    Freeman, H.D.; Hartley, J.N.; Gee, G.W.

    1983-11-01

    Pacific Northwest Laboratory (PNL), as part of the Department of Energy (DOE) Uranium Mill Tailings Remedial Action Project (UMTRAP) technology development program, has conducted three large-scale field tests of radon covers at the uranium mill tailings pile in Grand Junction, Colorado. The barrier systems, monitored for radon flux for over two years, include earthen, multilayer, and asphalt emulsion covers. Results of the monitoring have shown that a variety of cover systems can meet the Environmental Protection Agency (EPA) standard. The most effective covers tested were asphalt emulsion and earthen (mancos shale). 10 references, 7 figures, 1 table

  17. Use of RAMARN meters within the Radon Program of the Czech Republic

    International Nuclear Information System (INIS)

    Holecek, J.; Otahal, P.; Bercikova, M.; Slovak, J.

    2017-01-01

    The RAMARN system, produced by the National Institute for Nuclear Chemical and Biological Protection, is designed for the time integral determination of radon concentration. During it production, the properties of the solid state nuclear track detector with sensitive layer Kodak LR 115 were used. This detector is placed in a polypropylene diffusion chamber and exposed for 2 to 14 months. During exposure, the polymeric cellulose nitrate, which forms a sensitive layer of the detector through the alpha particles, is being damaged. The damage is visualized by etching in aqueous sodium hydroxide solution. After the etching, the damage is seen as white tracks in the red background. In the process of evaluation, the determination of the number of tracks per unit area is determined using a conversion factor established by cooperation with the Authorized Metrology Center K 113 for the radon concentration and equilibrium equivalent radon concentration calibration. The systems are regularly verified by the Authorized Metrology Center. The RAMARN systems are also involved in interlaboratory comparative measurements abroad. The easy construction and high reliability of the systems allowed their use in the Radon Program of the Czech Republic. The Radon Program of the Czech Republic from 2010 to 2019 - The Action Plan builds on the results of the Radon Program of the Czech Republic, which was approved for the period from 2000 to 2009 by Government Resolution No. 538 of 31 May 1999, supplemented by Government Resolution No. 970 of 7 October 2002. It was prepared in accordance with the valid legal regulation of the Czech Republic in the field of radiation protection and took into account the current trends in the EU member states. The Czech Action Plan includes an Intelligence Strategy, anti-radon prevention, regulation of the existing radon exposure and Expert scientific and technical support to achieve the goals of the Action plan. More than 110,000 RAMARN systems, of which the

  18. Map showing radon potential of rocks and soils in Montgomery County, Maryland

    Science.gov (United States)

    Gundersen, L.C.; Reimer, G.M.; Wiggs, C.R.; Rice, C.A.

    1988-01-01

    This report summarizes the radon potential of Montgomery County in the context of its geology. Radon is a naturally occurring gas produced by the radioactive decay of uranium. Radon produced by uraniferous rocks and soils may enter a house through porous building materials and through openings in walls and floors. Radon gases has a tendency to move from the higher pressure commonly existing in the soil to the lower pressure commonly existing in the house. The U.S. Environmental Protection Agency (U.S. EPA, 1986a) estimates that elevated levels of indoor radon may be associated with 5,000 to 20,000 of the 130,000 lung cancer deaths per year. They also estimate that 8 to 12 percent of the homes in the United States will have annual average indoor radon levels exceeding 4 picoCuries per liter of air (pCi/L). Above this level, the U.S. EPA recommends homeowners take remedial action. May factors control the amount of radon which may enter a home from the geologic environment. Soil drainage, permeability, and moisture content effect the amount of radon that can be released from rocks and soils (known as the emmanation) and may limit or increase how far it can migrate. Well drained, highly permeable soils facilitate the movement of radon. Soils with water content in the 8 to 15 percent range enhance the emmanation of radon (Lindmark, 1985). Daily and seasonal variations in soil and indoor radon can be caused by meteorologic factors such as barometric pressure, temperature, and wind (Clements and Wilkening, 1974; Schery and other, 1984). Construction practices also inhibit or promote entry of radon into the home (U.S. EPA, 1986b). In general, however, geology controls the source and distribution of radon (Akerblom and Wilson, 1982; Gundersen and others, 1987, 1988; Sextro and others, 1987; U.S. EPA, 1983; Peake, 1988; Peake and Hess, 1988). The following sections describe: 1) the methods used to measure radon and equivalent uranium (eU) in soil; 2) the radon potential

  19. QA/QC For Radon Concentration Measurement With Charcoal Canister

    International Nuclear Information System (INIS)

    Pantelic, G.; Zivanovic, M.; Rajacic, M.; Krneta Nikolic, J.; Todorovic, D.

    2015-01-01

    The primary concern of any measuring of radon or radon progeny must be the quality of the results. A good quality assurance program, when properly designed and diligently followed, ensures that laboratory staff will be able to produce the type and quality of measurement results which is needed and expected. Active charcoal detectors are used for testing the concentration of radon in dwellings. The method of measurement is based on radon adsorption on coal and measurement of gamma radiation of radon daughters. Upon closing the detectors, the measurement was carried out after achieving the equilibrium between radon and its daughters (at least 3 hours) using NaI or HPGe detector. Radon concentrations as well as measurement uncertainties were calculated according to US EPA protocol 520/5-87-005. Detectors used for the measurements were calibrated by 226Ra standard of known activity in the same geometry. Standard and background canisters are used for QA and QC, as well as for the calibration of the measurement equipment. Standard canister is a sealed canister with the same matrix and geometry as the canisters used for measurements, but with the known activity of radon. Background canister is a regular radon measurement canister, which has never been exposed. The detector background and detector efficiency are measured to ascertain whether they are within the warning and acceptance limits. (author).

  20. Cost-benefit considerations in the development of policies and procedures for controlling indoor exposure to radon and its decay products

    International Nuclear Information System (INIS)

    Puskin, J.S.; Guimond, R.J.; Napolitano, S.; Nelson, C.B.

    1989-01-01

    The applicability of ALARA to the problem of controlling residential radon levels is limited. Cost-benefit considerations can nevertheless be useful in guiding policy in this area. From a societal perspective, the cost-benefit balance for mitigating radon in homes to the EPA action level of 4 pCi/L, or lower, is generally better than for most programs aimed at reducing environmental risks. Reduction of radon levels in new homes tends to be less costly; moreover, reduced radon levels in new construction may be achievable with a net cost savings to the homeowner due to concomitant decreases in energy expenses. Since programs to reduced radon exposure rely on voluntary actions by homeowners, the societal cost-benefit balance cannot dictate the extent of radon mitigation efforts. However, both economic incentives and governmental guidance can influence these efforts. Cost-benefit analysis can be an important tool in formulating such guidance

  1. Radon-contaminated drinking water from private wells: an environmental health assessment examining a rural Colorado mountain community's exposure.

    Science.gov (United States)

    Cappello, Michael Anthony; Ferraro, Aimee; Mendelsohn, Aaron B; Prehn, Angela Witt

    2013-11-01

    In the study discussed in this article, 27 private drinking water wells located in a rural Colorado mountain community were sampled for radon contamination and compared against (a) the U.S. Environmental Protection Agency's (U.S. EPA's) proposed maximum contaminant level (MCL), (b) the U.S. EPA proposed alternate maximum contaminate level (AMCL), and (c) the average radon level measured in the local municipal drinking water system. The data from the authors' study found that 100% of the wells within the study population had radon levels in excess of the U.S. EPA MCL, 37% were in excess of the U.S. EPA AMCL, and 100% of wells had radon levels greater than that found in the local municipal drinking water system. Radon contamination in one well was found to be 715 times greater than the U.S. EPA MCL, 54 times greater than the U.S. EPA AMLC, and 36,983 times greater than that found in the local municipal drinking water system. According to the research data and the reviewed literature, the results indicate that this population has a unique and elevated contamination profile and suggest that radon-contaminated drinking water from private wells can present a significant public health concern.

  2. The rationale and experiences in implementing New Jersey's radon program

    International Nuclear Information System (INIS)

    Bynum, J.; Klotz, J.; Cahill, M.; Nicholls, G.

    1988-01-01

    The authors discuss how radon data from domestic modeling, mining studies, and animal studies provided a strong basis for New Jersey Department of Health (NJDOH) to support MJDEP's recommendation to establish a state radon program. The program, described in this report, focuses on promoting intensive testing by state residents followed by prompt remediation for residences with radon levels greater than or equal to four pico curies per liter. NJDOH believes a threshold for radiation carcinogens does not exist. Even at low levels, exposure to radiation is associated with some health risk. Hence, with consideration given to the length of exposure in the home prompt action is warranted until more definitive data suggest otherwise

  3. Review of selected state-of-the-art applications of diagnostic measurements for radon-mitigation planning. Report for April 1986-June 1987

    International Nuclear Information System (INIS)

    Hubbard, L.M.; Harrje, D.T.; Gadsby, K.J.; Sanchez, D.C.; Turk, B.H.

    1987-09-01

    Since late-1984, EPA's AEERL has supported a program to develop and demonstrate radon-mitigation techniques for single-family detached dwellings. As part of the program, projects have been started, directed at developing and demonstrating the use of diagnostic measurements in all phases of the radon-mitigation process. Diagnostic measurements are used to assess: (1) the radon sources strengths, variability, and locations; and, (2) radon transport to the house and its entry and distribution in the house as influenced by environmental, house characteristics, and occupancy factors. The diagnostic measurements reported include: (1) soil-gas grab sampling; (2) communication (air flow or pressure-field extension) tests; (3) whole house infiltration; (4) differential pressure, (5) gamma radiation; and, (6) radon flux. The paper concludes that the above selected diagnostic measurements were especially useful in characterizing houses with indoor radon problems attributable to soil-gas-borne radon that may be amenable to mitigation through the use of subslab ventilation

  4. Radon availability in New Mexico

    International Nuclear Information System (INIS)

    McLemore, V.T.

    1995-01-01

    The New Mexico Bureau of Mines and Mineral Resources (NMBMMR) in cooperation with the Radiation Licensing and Registration Section of the New Mexico Environment Department (NMED) and the US Environmental Protection Agency (EPA) have been evaluating geologic and soil conditions that may contribute to elevated levels of indoor radon throughout New Mexico. Various data have been integrated and interpreted in order to determine areas of high radon availability. The purpose of this paper is to summarize some of these data for New Mexico and to discuss geologic controls on the distribution of radon. Areas in New Mexico have been identified from these data as having a high radon availability. It is not the intent of this report to alarm the public, but to provide data on the distribution of radon throughout New Mexico

  5. Modeled atmospheric radon concentrations from uranium mines

    Energy Technology Data Exchange (ETDEWEB)

    Droppo, J.G.

    1985-04-01

    Uranium mining and milling operations result in the release of radon from numerous sources of various types and strengths. The US Environmental Protection Agency (EPA) under the Clean Air Act, is assessing the health impact of air emissions of radon from underground uranium mines. In this case, the radon emissions may impact workers and residents in the mine vicinity. To aid in this assessment, the EPA needs to know how mine releases can affect the radon concentrations at populated locations. To obtain this type of information, Pacific Northwest Laboratory used the radon emissions, release characteristics and local meterological conditions for a number of mines to model incremental radon concentrations. Long-term, average, incremental radon concentrations were computed based on the best available information on release rates, plume rise parameters, number and locations of vents, and local dispersion climatology. Calculations are made for a model mine, individual mines, and multiple mines. Our approach was to start with a general case and then consider specific cases for comparison. A model underground uranium mine was used to provide definition of the order of magnitude of typical impacts. Then computations were made for specific mines using the best mine-specific information available for each mine. These case study results are expressed as predicted incremental radon concentration contours plotted on maps with local population data from a previous study. Finally, the effect of possible overlap of radon releases from nearby mines was studied by calculating cumulative radon concentrations for multiple mines in a region with many mines. The dispersion model, modeling assumptions, data sources, computational procedures, and results are documented in this report. 7 refs., 27 figs., 18 tabs.

  6. Modeled atmospheric radon concentrations from uranium mines

    International Nuclear Information System (INIS)

    Droppo, J.G.

    1985-04-01

    Uranium mining and milling operations result in the release of radon from numerous sources of various types and strengths. The US Environmental Protection Agency (EPA) under the Clean Air Act, is assessing the health impact of air emissions of radon from underground uranium mines. In this case, the radon emissions may impact workers and residents in the mine vicinity. To aid in this assessment, the EPA needs to know how mine releases can affect the radon concentrations at populated locations. To obtain this type of information, Pacific Northwest Laboratory used the radon emissions, release characteristics and local meterological conditions for a number of mines to model incremental radon concentrations. Long-term, average, incremental radon concentrations were computed based on the best available information on release rates, plume rise parameters, number and locations of vents, and local dispersion climatology. Calculations are made for a model mine, individual mines, and multiple mines. Our approach was to start with a general case and then consider specific cases for comparison. A model underground uranium mine was used to provide definition of the order of magnitude of typical impacts. Then computations were made for specific mines using the best mine-specific information available for each mine. These case study results are expressed as predicted incremental radon concentration contours plotted on maps with local population data from a previous study. Finally, the effect of possible overlap of radon releases from nearby mines was studied by calculating cumulative radon concentrations for multiple mines in a region with many mines. The dispersion model, modeling assumptions, data sources, computational procedures, and results are documented in this report. 7 refs., 27 figs., 18 tabs

  7. FOLLOW-UP RADON MEASUREMENTS IN 14 MITIGATED SCHOOLS

    Science.gov (United States)

    The report gives results of a determination of the long-term performance of radon mitigation systems installed in U. S. EPA research schools: radon measurements were conducted in 14 schools that had been mitigated between 1988 and 1991. The measurements were made between Februar...

  8. Testing of indoor radon-reduction techniques in central Ohio houses: Phase 1 (Winter 1987-1988). Report for October 1987-August 1988 (Final)

    International Nuclear Information System (INIS)

    Findlay, W.O.; Robertson, A.; Scott, A.G.

    1989-07-01

    The U.S. Environmental Protection Agency (EPA) has a program to demonstrate practical, cost-effective methods to reduce indoor radon concentrations in housing to 150 Bq/cu m (4 pCi/L) or less. The complete program will evaluate the full range of radon-reduction methods, i.e., house ventilation, sealing of entry routes, soil ventilation, radon removal from water, and air cleaning in the full range of housing substructure types and building styles, and geological conditions across the continental United States. The program described in the report demonstrated certain radon-reduction methods in housing and geology typical of southern Ohio in particular, and the central Great Plains States in general. The testing of radon-mitigation systems in Ohio houses is envisioned as taking place in two phases. The report describes Phase 1, which was carried out in 16 existing houses in the Dayton area during the 1987-1988 heating season

  9. Reconstruction of national distribution of indoor radon concentration in Russia using results of regional indoor radon measurement programs

    International Nuclear Information System (INIS)

    Yarmoshenko, I.; Malinovsky, G.; Vasilyev, A.; Zhukovsky, M.

    2015-01-01

    The aim of the paper is a reconstruction of the national distribution and estimation of the arithmetic average indoor radon concentration in Russia using the data of official annual 4-DOZ reports. Annual 4-DOZ reports summarize results of radiation measurements in 83 regions of Russian Federation. Information on more than 400 000 indoor radon measurements includes the average indoor radon isotopes equilibrium equivalent concentration (EEC) and number of measurements by regions and by three main types of houses: wooden, one-storey non-wooden, and multi-storey non-wooden houses. To reconstruct the national distribution, all-Russian model sample was generated by integration of sub-samples created using the results of each annual regional program of indoor radon measurements in each type of buildings. According to indoor radon concentration distribution reconstruction, all-Russian average indoor radon concentration is 48 Bq/m"3. Average indoor radon concentration by region ranges from 12 to 207 Bq/m"3. The 95-th percentile of the distribution is reached at indoor radon concentration 160 Bq/m"3. - Highlights: • Reconstruction of indoor radon concentration distribution in Russia was carried out. • Data of official annual 4-DOZ reports were used. • All-Russian average indoor radon concentration is 48 Bq/m"3. • The 95-th percentile is 160 Bq/m"3.

  10. Health effects and risks of radon exposure

    International Nuclear Information System (INIS)

    Cross, F.T.

    1990-01-01

    In view of the current widespread concern about the risks associated with indoor radon exposures, this paper explores the evidence on risk from human epidemiology studies, particularly in reference to EPA's 4-pCi/L action level value and from animal studies. While the EPA 4-pCi/L level has no legal force and is not a standard per se, it is becoming a de facto standard as several states are considering the level in pending legislation. Although risk can also be related to radiation dose from radon exposure, this perspective on risk is not treated in this chapter

  11. The history, development and the present status of the radon measurement programme in the United States of America

    International Nuclear Information System (INIS)

    George, A.C.

    2015-01-01

    The US radon measurement programme began in the late 1950's by the US Public Health Service in Colorado, New Mexico and Utah during the uranium frenzy. After the 1967 Congressional Hearings on the working conditions in uranium mines, the US Atomic Energy Commission (AEC) was asked to conduct studies in active uranium mines to assess the exposure of the miners on the Colorado Plateau and in New Mexico. From 1967 to 1972, the Health and Safety Laboratory of the US AEC in New York investigated more than 20 uranium mines for radon and radon decay product concentrations and particle size in 4 large uranium mines in New Mexico. In 1970, the US Environmental Protection Agency (EPA) was established and took over some of the AEC radon measurement activities. Between 1975 and 1978, the Environmental Measurements Laboratory of the US Department of Energy conducted the first detailed indoor radon survey in the USA. Later in 1984, the very high concentrations of radon found in Pennsylvania homes set the wheels in motion and gave birth to the US Radon Industry. The US EPA expanded its involvement in radon issues and assumed an active role by establishing the National Radon Proficiency Program to evaluate the effectiveness of radon measurement and mitigation methods. In 1998, due to limited resources EPA privatised the radon programme. This paper presents a personal perspective of past events and current status of the US radon programme. It will present an update on radon health effects, the incidence rate of lung cancer in the USA and the number of radon measurements made from 1988 to 2013 using short-term test methods. More than 23 million measurements were made in the last 25 y and as a result more than 1.24 million homes were mitigated successfully. It is estimated that <2 % of the radon measurements performed in the USA are made using long-term testing devices. The number of homes above the US action level of 148 Bq m -3 (4 pCi l -1 ) may be ∼8.5 million because ∼50

  12. Publications about Radon

    Science.gov (United States)

    There is no known safe level of exposure to radon. EPA strongly recommends that you fix your home if your test shows 4 picocuries (pCi/L) or more. These publications and resources will provide you with the information you need to fix your home.

  13. Navy radon assessment and mitigation program: Final report

    International Nuclear Information System (INIS)

    1994-10-01

    This final report encompasses the events from the beginning of the Navy Radon Assessment and Mitigation Program to the closure of the program on October 31, 1994. Included in the report are discussions of the phases of the program including screening, assessment, mitigation, and post-mitigation. The primary discussion involves screening and assessment. The report addresses recommendations made to the Naval Facilities Engineering Command by the Hazardous Waste Remedial Actions Program of Martin Marietta Energy Systems, Inc., and the final decisions that were made. Special emphasis is placed on quality assurance/quality control (QA/QC), since QA/QC was given top priority during the implementation of this program. Included in the discussion on QA/QC are ana overview of the measurement process, positive and negative controls, replicated measurements, and application of chamber exposures to data calibration. The report concludes with a discussion of testing considerations for naval facilities and radon mitigation considerations for the Department of the Navy

  14. Radon reduction in crawl-space houses

    International Nuclear Information System (INIS)

    Osborne, M.C.; Moore, D.G.; Southerlan, R.E.; Brennan, T.; Pyle, B.E.

    1989-01-01

    This paper gives results of an EPA study of radon-mitigation alternatives for crawl space houses in several houses in Nashville, TN. Application of one of these alternative mitigation options, suction under a polyethylene membrane, has been successful in significantly reducing radon levels in both the crawl space and the house. The large radon concentrations measured under unvented plastic ground covers and the moisture barriers found in many crawl spaces can act as radon-rich reservoirs capable of contaminating a crawl space and house during periods of depressurization. With the exhaust components of the mitigation system in place, radon levels below the plastic decreased by more than 95% under both passive and active suction conditions. Based on the study, the design of a cost-effective subplastic suction passive radon mitigation system for crawl spaces seems promising

  15. Comparative study of radon exposure in Canadian homes and uranium mines - a discussion on the importance of national radon program

    International Nuclear Information System (INIS)

    Chen, Jing

    2017-01-01

    The history of lung cancer in uranium miners is well known for over hundreds of years when the disease was referred to as 'miner's disease' or 'mountain sickness'. Radon levels in uranium mines have decreased significantly over the past 30 years as a result of effective radiation protection measures at workplaces. For the most recent 10-year period, the average radon concentrations to underground and surface workers in Canadian uranium mines were 111 and 11 Bq m -3 , respectively. Based on the recent radon survey carried out in roughly 14 000 homes in 121 health regions across Canada and the more recent radon and thoron survey in 33 Canadian cities and 4000 homes, the average radon concentration in Canadian homes is 77 Bq m -3 . This study demonstrates that, nowadays, workers are exposed to radon in underground mines at a comparable radon level to what Canadians are exposed to at home. Since exposure to indoor radon is the main source of natural radiation exposure to the population, it is important for the National Radon Program to further increase radon awareness, and to encourage more Canadians to take appropriate actions to reduce radon exposure. (authors)

  16. Contribution of waterborne radon to home air quality

    International Nuclear Information System (INIS)

    Deb, A.K.

    1994-01-01

    Radon-222 is a member of the uranium decay chain and is formed from the decay of radium-226. Radon and its decay products emit alpha particles during the decay process. If radon is inhaled, alpha particles emitted from inhaled radon and its daughters increase the risk of lung cancer. Radon is soluble in water; thus when radon comes in contact with groundwater it dissolves. The radon concentration in groundwater may range from 100 pCi/L to 1,000,000 pCi/L. When water with a high radon level is used in the home, radon is released from the water to the air and thus can increase indoor air radon concentration. Considering the estimated health risk from radon in public water supply systems, EPA has proposed a maximum contaminant level (MCL) of 300 pCi/L for radon in public drinking water supplies. To address the health risks of radon in water and the proposed regulations, the American Water Works Association Research Foundation (AWWARF) initiated a study to determine the contribution of waterborne radon to radon levels in indoor household air

  17. EPA's Radioactive Source Program

    International Nuclear Information System (INIS)

    Kopsick, D.

    2004-01-01

    The US EPA is the lead Federal agency for emergency responses to unknown radiological materials, not licensed, owned or operated by a Federal agency or an Agreement state (Federal Radiological Emergency Response Plan, 1996). The purpose of EPA's clean materials programme is to keep unwanted and unregulated radioactive material out of the public domain. This is achieved by finding and securing lost sources, maintaining control of existing sources and preventing future losses. The focus is on both, domestic and international fronts. The domestic program concentrates on securing lost sources, preventing future losses, alternative technologies like tagging of radioactive sources in commerce, pilot radioactive source roundup, training programs, scrap metal and metal processing facilities, the demolition industry, product stewardship and alternatives to radioactive devices (fewer radioactive source devices means fewer orphan sources). The international program consists of securing lost sources, preventing future losses, radiation monitoring of scrap metal at ports and the international scrap metal monitoring protocol

  18. Evaluation of radon occurrence in groundwater from 16 geologic units in Pennsylvania, 1986–2015, with application to potential radon exposure from groundwater and indoor air

    Science.gov (United States)

    Gross, Eliza L.

    2017-05-11

    Results from 1,041 groundwater samples collected during 1986‒2015 from 16 geologic units in Pennsylvania, associated with 25 or more groundwater samples with concentrations of radon-222, were evaluated in an effort to identify variations in radon-222 activities or concentrations and to classify potential radon-222 exposure from groundwater and indoor air. Radon-222 is hereafter referred to as “radon.” Radon concentrations in groundwater greater than or equal to the proposed U.S. Environmental Protection Agency (EPA) maximum contaminant level (MCL) for public-water supply systems of 300 picocuries per liter (pCi/L) were present in about 87 percent of the water samples, whereas concentrations greater than or equal to the proposed alternative MCL (AMCL) for public water-supply systems of 4,000 pCi/L were present in 14 percent. The highest radon concentrations were measured in groundwater from the schists, gneisses, and quartzites of the Piedmont Physiographic Province.In this study, conducted by the U.S. Geological Survey in cooperation with the Pennsylvania Department of Health and the Pennsylvania Department of Environmental Protection, groundwater samples were aggregated among 16 geologic units in Pennsylvania to identify units with high median radon concentrations in groundwater. Graphical plots and statistical tests were used to determine variations in radon concentrations in groundwater and indoor air. Median radon concentrations in groundwater samples and median radon concentrations in indoor air samples within the 16 geologic units were classified according to proposed and recommended regulatory limits to explore potential radon exposure from groundwater and indoor air. All of the geologic units, except for the Allegheny (Pa) and Glenshaw (Pcg) Formations in the Appalachian Plateaus Physiographic Province, had median radon concentrations greater than the proposed EPA MCL of 300 pCi/L, and the Peters Creek Schist (Xpc), which is in the Piedmont

  19. RADON MITIGATION IN SCHOOLS: CASE STUDIES OF RADON MITIGATION SYSTEMS INSTALLED BY EPA IN FOUR MARYLAND SCHOOLS ARE PRESENTED

    Science.gov (United States)

    The first part of this two-part paper discusses radon entry into schools, radon mitigation approaches for schools, and school characteristics (e.g., heating, ventilation, and air-conditioning -- HVAC-- system design and operation) that influence radon entry and mitigation system ...

  20. Investigation of the areas of high radon concentration in Gyeongju

    International Nuclear Information System (INIS)

    Lee, Jung Min; Park, Chan Hee; Kim, Shin Jae; Moon, Joo Hyun

    2013-01-01

    The aim of this study was to survey the radon concentrations at 21 elementary schools in Gyeongju, Republic of Korea, to identify those schools with high radon concentrations. Considering their geological characteristics and the preliminary survey results, three schools were finally placed under close scrutiny. For these three schools, continuous measurements over 48 h were taken at the principal's and administration office. The radon concentrations at one school, Naenam, exceeded the action level (148 Bq/m 3 ) established by the U.S. EPA, while those at the other two schools were below that level. - Highlights: • Preliminary measurements of the indoor radon concentrations were performed at the auditoriums in 23 elementary schools in Gyeongju. • Considering the geological characteristics and preliminary survey results, three elementary schools were screened for closer scrutiny. • For the three schools, continuous measurements were made at their principal's and administration offices over 48-h period. • The scrutiny revealed one elementary school of high radon concentration much higher than the U.S. EPA action level

  1. Cost and effectiveness of radon barrier systems

    International Nuclear Information System (INIS)

    Baker, E.G.; Freeman, H.D.; Hartley, J.N.; Gee, G.W.

    1982-12-01

    Earthen, asphalt, and multilayer radon barrier systems can all provide reduction in the amount of radon gas released from uranium mill tailings. Pacific Northwest Laboratory field tested all three types of covers at Grand Junction, Colorado during the summer of 1981. All nine individual radon barrier systems tested currently meet the EPA standard for radon flux of 20 pCi m - 2 s - 1 . The cost of the asphalt and 3m earthen covers were about the same at the field test. Multilayer covers were significantly more costly. Cost estimates for three high priority western sites indicate 3m of earthen cover is the least costly radon barrier when earthen material is available at or near the disposal site. If earthen material must be imported more than 8 to 10 km asphalt and possibly multilayer radon barriers can be cost effective

  2. RECOMMENDED FOUNDATION FILL MATERIALS CONSTRUCTION STANDARD OF THE FLORIDA RADON RESEARCH PROGRAM

    Science.gov (United States)

    The report summarizes the technical basis for a recommended foundation fill materials standard for new construction houses in Florida. he radon-control construction standard was developed by the Florida Radon Research Program (FRRP). ill material standards are formulated for: (1)...

  3. The history, development and the present status of the radon measurement programme in the United States of America.

    Science.gov (United States)

    George, A C

    2015-11-01

    The US radon measurement programme began in the late 1950s by the US Public Health Service in Colorado, New Mexico and Utah during the uranium frenzy. After the 1967 Congressional Hearings on the working conditions in uranium mines, the US Atomic Energy Commission (AEC) was asked to conduct studies in active uranium mines to assess the exposure of the miners on the Colorado Plateau and in New Mexico. From 1967 to 1972, the Health and Safety Laboratory of the US AEC in New York investigated more than 20 uranium mines for radon and radon decay product concentrations and particle size in 4 large uranium mines in New Mexico. In 1970, the US Environmental Protection Agency (EPA) was established and took over some of the AEC radon measurement activities. Between 1975 and 1978, the Environmental Measurements Laboratory of the US Department of Energy conducted the first detailed indoor radon survey in the USA. Later in 1984, the very high concentrations of radon found in Pennsylvania homes set the wheels in motion and gave birth to the US Radon Industry. The US EPA expanded its involvement in radon issues and assumed an active role by establishing the National Radon Proficiency Program to evaluate the effectiveness of radon measurement and mitigation methods. In 1998, due to limited resources EPA privatised the radon programme. This paper presents a personal perspective of past events and current status of the US radon programme. It will present an update on radon health effects, the incidence rate of lung cancer in the USA and the number of radon measurements made from 1988 to 2013 using short-term test methods. More than 23 million measurements were made in the last 25 y and as a result more than 1.24 million homes were mitigated successfully. It is estimated that USA are made using long-term testing devices. The number of homes above the US action level of 148 Bq m(-3) (4 pCi l(-1)) may be ∼8.5 million because ∼50 million homes were added since 1990 to the home

  4. Carcinogenic risk associated with radon-enriched well water

    International Nuclear Information System (INIS)

    Mose, D.G.; Mushrush, G.W.

    1997-01-01

    A comparison has been made between radon in drinking water and the incidence of cancer using a set of home occupants in Virginia and Maryland. In a subset of people who drink radon-free but chlorinated drinking water from a reservoir, about 3% develop some type of cancer. In a subset of people who drink low-radon water from private water wells, about 3% develop cancer. In a subset who drink high-radon well water, about 6% develop cancer. A comparison with Environmental Protection Agency (EPA) estimates of cancer related to airborne radon indicates that for the general population, the incidence of radon-related cancer from drinking water is similar to the incidence of cancer from inhaled radon. For the 10% of the population that consumes well water and, in particular, for the 5% of the population that consumes high-radon well water, the drinking water carries a considerably higher cancer risk than inhaling airborne radon

  5. The school evaluation program

    International Nuclear Information System (INIS)

    Fisher, E.; Harrison, J.; Turner, W.

    1990-01-01

    This paper reports on a pilot program to provide classroom and field training to school facility operators that was implemented by the U.S. Environmental Protection Agency's Office of Radiation Programs in 1989. This program consisted of two phases. The first phase developed and delivered a three-day workshop in Nashville, Tennessee. As a result of the workshop a second phase was initiated. The second phase investigated several school buildings with elevated indoor radon levels in the Western United States. Radon entry mechanisms were identified. Measurements to evaluate soil depressurization as a radon control method were made and HVAC systems were characterized. Measurements were made to evaluate HVAC modification as a radon control method. Building shell tightness measurements were made and information was collected to judge the suitability of potential sites for additional EPA sponsored 'hands on' school training. Physical and institutional problem areas were identified

  6. The effect of desiccation on UMTRA Project radon barrier materials

    International Nuclear Information System (INIS)

    1990-11-01

    The proposed US Environmental Protection Agency (EPA) groundwater standards (40 CFR 192) require that Uranium Mill Tailings Remedial Action (UMTRA) Project remedial action designs meet low numerical limits for contaminants contained in water or vapors exiting the disposal cell embankments. To meet the standards, a cover of compacted, fine-grained soil is placed over UMTRA Project embankments. One of the functions of this cover is to limit infiltration into the disposal cell . The hydraulic conductivity of this infiltration barrier must be low in order to reduce the resultant seepage from the base of the cell to the extent necessary to comply with the proposed EPA groundwater standards. Another function of this cover is to limit the emission of radon gas. The air permeability of the cover must be low in order to reduce radon emissions to comply with EPA standards. Fine-grained soils exposed to evaporation will dry. Continued exposure will cause shrinking that, if allowed to continue, will eventually result in the development of cracks. The results of the cracking could be an increase in the hydraulic conductivity and an increase in the air permeability. This could then allow additional infiltration and increased radon emissions. Cracking of the radon barrier has been noted at one UMTRA Project location. The potential for cracking of the radon barrier during construction has been addressed by requiring moistening of previously compacted surfaces prior to placing additional lifts. The efficacy of these treatments has not been verified. The potential for cracking after construction of the cover is completed has also not been examined. The purpose of this study is to evaluate the potential for cracking of the radon barrier both during construction and after completion of the cover. The effect of shrinkage cracking on the performance of the radon barrier will also be examined

  7. A survey on radon reduction efficiency of zeolite and bentonite in a chamber with artificially elevated radon concentration

    International Nuclear Information System (INIS)

    Mortazavi, S.M.J.

    2007-01-01

    Complete text of publication follows. Objective: Zeolite which is made of a special crystalline structure is a naturally occurring mineral group and can be used in radioactive waste management for site remediation /decontamination. There are a wide variety of naturally occurring and synthetic zeolites, each with a unique structure. The cations in zeolite are highly mobile and can be exchanged for other cationic species. On the other hand, bentonite forms from weathering of volcanic ash. This material may be used as an engineering barrier to enclose nuclear waste. In this study, radon reducing properties of zeolite and bentonite have been investigated. Methods: Using radioactive lantern mantle, a radon prone area with radon levels reaching the EPA's action level (200 Bq/m 3 ) was designed. Two sets of identical chambers (cylindrical chambers, diameter 10 cm, height 16 cm) were used in this study. No zeolite/bentonite was used in the 1 st set of the chambers. A thin layer of either zeolite or bentonite powder was applied to the base of the first set of chambers. An unburned radioactive lantern mantle (activity 800 Bq) was placed in all chambers (both sets) to artificially increase the radon level inside the chamber and simulate the condition of a radon prone area. Radon level monitoring was performed by using a PRASSI portable radon gas survey meter. Results: After placing the cap on its place, the radon levels inside the 1 st set of the chambers were 871.9, 770.3, 769.2 and 635.7 Bq/m 3 after 15, 30, 45 and 60 minutes respectively. Zeolite significantly decreased the radon concentration inside the chambers and radon levels were 367.9, 435.4, 399.0 and 435.4 Bq/m 3 after 15, 30, 45 and 60 minutes. The observed reduction in the radon level was statistically significant. As the radon concentrations in identical chambers with Bentonite were 550.7, 526.5, 536.2 and 479.8 Bq/m 3 after 15, 30, 45 and 60 minutes respectively, it is evident that zeolite is more efficient in

  8. Radiological Programs- Ambient Radon at the Yucca Mountain Site (SCPB:NA)

    International Nuclear Information System (INIS)

    TRW

    1999-01-01

    This report summarizes the results of the ambient radon monitoring activities conducted by the Radiological/Environmental Field Programs Department of the Civilian Radioactive Waste Management and Operating Contractor (CRWMS M and O), Yucca Mountain Site Characterization Office. Overall, outdoor radon concentrations measured at the Yucca Mountain site were within the range of those reported for other areas in Nevada and the continental United States. Though there was some evidence of trends with time at some monitoring sites, regional atmospheric radon concentrations to date, do not appear to have changed significantly since the inception of site characterization activities. A preliminary dose assessment yielded an estimated annual effective dose equivalent of 134 mrem based on a continuous exposure to the average ambient radon concentration measured at the Yucca Mountain site. Concentrations were measured using two types of systems, passive electret ion chambers (EIC) and continuous radon monitors (CRM). The EICs produced time-averaged radon concentration data and the CRMs were used to study radon fluctuations over time. Between 1991 and 1995, the mean radon concentration at the site, as measured by EICs placed one meter above ground level, was 0.32 ± 0.15 pCi L -1 . Radon concentrations varied between monitoring locations and between years. Station NF38, located near the North Portal of the Exploratory Studies Facility (ESF), exhibited the highest overall average radon concentration at 0.55 pCi L -1 (1992 to 1995). Concentrations appear to cycle diurnally, generally peaking in the early morning hours and being lowest in the afternoon. The data also suggested that radon concentrations may fluctuate seasonally. The work accomplished between 1991 and 1995, established radon levels in the general area surrounding Yucca Mountain. It is recommended that further work focus directly on those locations that have the greatest potential for influencing ambient radon levels

  9. Fluid-based radon mitigation technology development for industrial applications

    International Nuclear Information System (INIS)

    Liu, K.V.; Gabor, J.D.; Holtz, R.E.; Gross, K.C.

    1996-01-01

    The objective of the radon mitigation technology development effort is to develop an efficient and economical radon gas removal technology based on a fluid absorption process. The technology must be capable of cleaning up a wide range of radon gas stream concentrations to a level that meets EPA gas emission standards for residential and industrial applications. Argonne has recently identified a phenomenon that offers the possibility of radon recovery from the atmosphere with high efficiency at room temperature, and radon release at slightly elevated temperatures (50-60 degrees C.) such a device would offer numerous substantial advantages over conventional cryogenic charcoal systems for the removal of radon. Controlled sources of radon in Argonne's radon research facility are being used to quantitatively assess the performance of a selected class of absorbing fluids over a range of radon concentrations. This paper will discuss the design of laboratory- and engineering-scale radon absorption units and present some preliminary experimental test results

  10. 40 CFR 147.1703 - EPA-administered program-Indian lands.

    Science.gov (United States)

    2010-07-01

    ... Carolina § 147.1703 EPA-administered program—Indian lands. (a) Contents. The UIC program for all classes of wells on Indian lands in the State of North Carolina is administered by EPA. This program consists of... these requirements. (b) Effective date. The effective date of the UIC program for Indian lands in North...

  11. Overview of current radon and radon daughter research at LBL

    International Nuclear Information System (INIS)

    1983-01-01

    This report provides a brief summary of radon and radon daughter research at Lawrence Berkeley Laboratory. The radon and radon daughter research program has two broad goals: (1) the study of sources of radon and its subsequent transport into houses, and (2) research on the behavior of radon daughters in indoor environments. Additional research effort is directed to several auxiliary areas, including development of instrumentation and monitoring techniques, studies of indoor air movement, and measurement and control of indoor particulate concentrations

  12. Radon Exhalation from some Finishing Materials Frequently used in Syria

    International Nuclear Information System (INIS)

    Shweikani, R.; Raja, G.

    2011-01-01

    Building materials are one of the main radon sources in dwellings. Therefore, the determination of radon exhalation from these materials will help in prediction the existence of dwelling with potential radon risk. Ceramic tiles and marble samples were collected from Syrian local market. The correlation between radon exhalation from these materials and radium-226 content was studied. Results showed that there is no clear relation between radium content and radon exhalation rate, and the exhalation of radon did not exceed the permissible limits of American Environment Protection Agency (EPA). In addition, the additional annual dose from radon and gamma of the natural radioactivity in ceramic and marble when used as finishing materials in houses was also estimated and found to be not exceeding 20 μSv and 35 μSv from radon and gamma respectively. (author)

  13. Radon exhalation from some Finishing Materials frequently used in Syria

    International Nuclear Information System (INIS)

    Shweikani, R.; Raja, G.

    2009-02-01

    Building materials are one of the main radon sources in dwellings. Therefore, the determination of radon exhalation from these materials will help in prediction the existence of dwelling with potential radon risk. Ceramic tiles and marble samples were collected from Syrian local market. The correlation between radon exhalation from these materials and radium-226 content were studied. Results showed that there is no clear relation between radium content and radon exhalation rate, and the exhalation of radon did not exceed the permissible limits of American Environment Protection Agency (EPA). In addition, the additional annual dose from radon and gamma of the natural radioactivity in ceramic and marble when used as finishing materials in houses were also estimated and found to be not exceeding 20 μSv and μ35 Sv from radon and gamma respectively. (author)

  14. Living with radon and uncertainty

    International Nuclear Information System (INIS)

    Frame, P.W.

    1990-01-01

    Lung cancer is the second leading cause of death in the United States, heart disease is the first. In 1990 an estimated 142,000 will die form lung cancer and approximately 157,000 new cases will be reported. Of the latter, only 20,000 are expected to survive beyond five years. For all practical purposes lung cancer is 100% fatal. This paper reports that he Environmental Protection Agency has predicted that 8,400-43,000 lung caner deaths each year can be attributed to radon with their best estimate at 21,600. If the EPA's estimate of 21,600 is correct, radon is responsible for 15% of lung cancer deaths. It would also be responsible for approximately the same number of deaths as homicides, the various diseases of infancy, and leukemia. Radon has also been cited in several recent reports as a possible cause of leukemia, cancer of the kidney and melanoma. It is no wonder that radon is widely considered the most hazardous indoor air pollutant

  15. Indoor radon measurements in dwellings of Mizoram

    International Nuclear Information System (INIS)

    Lalramengzami, R.; Laldawngliana, C.; Sinha, D.; Ghosh, S.; Dwivedi, K.K.

    1995-01-01

    The concentration of indoor radon has been measured in some dwellings of Mizoram state by employing time integrated method using solid state nuclear track detector. This state is located in the north eastern region of India which has been identified as a high background area. The indoor radon levels determined in this work are compared with data obtained from other regions of India and the Environmental Protection Agency (EPA) prescribed safe limit. (author). 7 refs., 2 figs

  16. Radon prevention in the design and construction of schools and other large buildings

    International Nuclear Information System (INIS)

    Leovic, K.W.; Craig, A.B.; Harris, D.B.

    1991-01-01

    The paper discusses radon prevention in the design and construction of schools and other large buildings. The U.S. EPA's Office of Research and Development (ORD) has started incorporating radon control measures into the design and construction of new schools and other large buildings. The goal of the new designs is twofold: (1) to prevent elevated radon levels in the completed building, and (2) to provide the protection at a fraction of the cost of retrofit systems. ORD's Air and Energy Engineering Research Laboratory (AEERL) has conducted the research necessary to develop viable designs. The Indoor Radon Abatement Act of 1988 set a national long-term goal for indoor radon of 0.5 picocurie per liter (pCi/L)--the same as that typically found in outdoor air. The EPA currently recommends that homeowners take action to reduce radon levels to below 4 pCi/L. To achieve the national goal set in the 1988 Act for new construction in radon-prone areas, AEERL research is using a combination of active subslab depressurization (ASD) and operation of the heating, ventilation, and air-conditioning (HVAC) system to pressurize buildings. These measures are described briefly, along with a case history of one building

  17. The Department of Energy's radon testing program

    International Nuclear Information System (INIS)

    Scott, H.L.; Dudney, C.S.; Wilson, D.L.; Gammage, R.B.

    1993-01-01

    The US Department of Energy recently completed an initial survey of indoor radon in its buildings in response to Public Law 100--551, the Indoor Radon Abatement Act of 1988. Other federal agencies have also conducted radon surveys. This paper presents an overview of the results from radon testing of several thousand buildings ranging from 100 m 2 to over 10,000 M 2 in size. In addition, we have examined results from groups of buildings, classified according to ventilation and usage characteristics. So far, there is no apparent difference among building classes. The paper also discusses our proposal for phased radon surveys. We suggest that first-phase results can be used to identify facilities with radon problems. In the second phase, we suggest measurements be made at a much higher sampling density at facilities with radon problems. The results of the second phase are expected to identify all buildings in need of mitigation

  18. Residents in a high radon potential geographic area: Their risk perception and attitude toward testing and mitigation

    International Nuclear Information System (INIS)

    Ferng, S.F.; Lawson, J.K.

    1996-01-01

    Boone County, Indiana was identified by the EPA as one of the high radon potential geographic areas. Health education campaigns are needed to prevent resident's unnecessary radon exposure. In order to design suitable programs, a questionnaire mail survey was conducted to measure socio-demographic characteristics of County resident's knowledge about radon, attitude toward radon testing and mitigation, support of education campaigns, and the best media to deliver radon education campaigns. A stratified random sampling method was applied for a total of 400 samples. The number of samples from each township/city was a proportion of their taxable parcels. The survey return rate was 39.8%. The data were analyzed by Epi Info and SPSS. The statistical significant level was set at α = 0.05. The results showed that resident's knowledge about radon was at a relatively superficial level. There was no association identified between the knowledge of radon and gender, age, family income, or education, except that females more frequently believed in false effects caused by radon. A significant correlation between radon knowledge and home radon tests was observed. Also found in this study was that respondents with better knowledge about diseases caused by radon had more confidence in radon mitigation actions. Newspaper was chosen by respondents as the most favorite media to deliver radon health education campaigns. Health education campaigns for the residents of Boone County might be conducted by local governments and/or other organizations

  19. Radon house doctor

    International Nuclear Information System (INIS)

    Nitschke, I.A.; Brennan, T.; Wadach, J.B.; O'Neil, R.

    1986-01-01

    The term house doctor may be generalized to include persons skilled in the use of instruments and procedures necessary to identify, diagnose, and correct indoor air quality problems as well as energy, infiltration, and structural problems in houses. A radon house doctor would then be a specialist in radon house problems. Valuable experience in the skills necessary to be developed by radon house doctors has recently been gained in an extensive radon monitoring and mitigation program in upstate New York sponsored by Niagara Mohawk Power Corporation and the New York State Energy Research and Development Authority. These skills, to be described in detail in this paper, include: (i) the use of appropriate instruments, (ii) the evaluation of the symptoms of a radon-sick house, (iii) the diagnostic procedures required to characterize radon sources in houses, (iv) the prescription procedures needed to specify treatment of the problem, (v) the supervision of the implementation of the treatment program, (vi) the check-up procedures required to insure the house cured of radon problems. 31 references, 3 tables

  20. Outdoor radon monitoring plan for the UMTRA Project sites

    International Nuclear Information System (INIS)

    1986-02-01

    This document describes the monitoring schedules and methods used to measure ambient radon concentrations around Uranium Mill Tailings Remedial Action (UMTRA) Project sites. Radon monitoring at both processing sites and disposal sites is performed primarily for two reasons. The first, and foremost, of these is to provide a means to keep the off-site radon concentrations during the construction activities As Low As Reasonably Achievable (ALARA). The second purpose is to provide a basis for comparison with the EPA standards developed for the UMTRA Project. Radon monitoring data are also used to demonstrate compliance with ambient concentration standards and for public information due to concern about potential radiation releases during construction. 1 fig., 1 tab

  1. Monitoring radon reduction in Clinton, New Jersey houses

    International Nuclear Information System (INIS)

    Osborne, M.C.; Brennan, T.; Michaels, D.

    1987-01-01

    In 1986, a preliminary survey of houses in Clinton, New Jersey, conducted by the New Jersey Department of Environmental Protection (DEP), identified more than 50 houses with indoor radon concentrations greater than 100 pCi/l in the subdivision of Clinton Knolls. Many of these houses had radon concentrations of 600 pCi/l or higher. At the request of the New Jersey DEP, EPA's Air and Energy Engineering Research Laboratory, AEERL, initiated a project to develop and demonstrate cost-effective radon reduction techniques in 10 representative Clinton Knolls houses. Radon reduction was to be completed before the beginning of the 1986-1987 heating season to keep the exposure of residents to a minimum. Additional data were collected to add to the general body of information on radon transport and its control in houses; however, the data collected in this study were secondary to the pressing need of demonstrating effective radon reduction techniques. The authors describe these techniques and discuss the data on radon transport and control in this project

  2. Predictions of lung cancer based on county averages for indoor radon versus the historic incidence of regional lung cancer

    International Nuclear Information System (INIS)

    Mose, D.G.; Chrosniak, C.E.; Mushrush, G.W.

    1992-01-01

    After a decade of effort to determine the health risk associated with indoor radon, the efforts of the US Environmental Protection Agency have prevailed in the US, and 4 pCi/1 is commonly used as an Action Level. Proposals by other groups supporting lower or higher Action Levels have failed, largely due to paucity of information supporting any particular level of indoor radon. The authors' studies have compared indoor radon for zip code and county size areas with parameters such as geology, precipitation and home construction. Their attempts to verify the relative levels of lung cancer using US-EPA estimates of radon-vs-cancer have not been supportive of the EPA risk estimates. In general, when they compare the number of lung cancer cases in particular geological or geographical areas with the indoor radon levels in that area, they find the EPA predicted number of lung cancer cases to exceed the total number of lung cancer cases from all causes. Comparisons show a correlation between the incidence of lung cancer and indoor radon, but the level of risk is about 1/10 that proposed by the US-EPA. Evidently the assumptions used in their studies are flawed. Even though they find lower risk estimates using many counties in several states, fundamental flaws must be present in this type of investigation. Care must be taken in presenting health risks to the general population in cases, such as in indoor radon, where field data do not support risk estimates obtained by other means

  3. Determination of radon in the air of housings of the Aguascalientes municipality; Determinacion de radon en el aire en viviendas del municipio de Aguascalientes

    Energy Technology Data Exchange (ETDEWEB)

    Jasso G, M.R.; Lira P, M.G.; Bonilla P, A.; Ruvalcaba S, L.; Gutierrez S, K.M.; Sandoval A, G.E. [Instituto Tecnologico de Aguascalientes, Av. Lopez Mateos 1801, 20256 Aguascalientes (Mexico); Sanchez H, L. [CNSNS, Dr. Barragan 779, 03020 Mexico D.F. (Mexico)]. e-mail: jassogonzalezre@yahoo.com.mx

    2006-07-01

    This study reports the results of the first exploratory sampling of the radon concentration in the air in a group of housings of the Aguascalientes City, Mexico. The municipality of Aguascalientes was divided in 4 sampling areas considering a total of 179 housings. In these housings, the radon concentration in the air was monitored during a period of 10 days. The results obtained in this study indicate that the radon concentration in the air of 45% of the sampling housings overcomes the concentration limit of 250 Bq/m{sup 3} suggested by the EPA. (Author)

  4. Computations of concentration of radon and its decay products against time. Computer program; Obliczanie koncentracji radonu i jego produktow rozpadu w funkcji czasu. Program komputerowy

    Energy Technology Data Exchange (ETDEWEB)

    Machaj, B. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1996-12-31

    This research is aimed to develop a device for continuous monitoring of radon in the air, by measuring alpha activity of radon and its short lived decay products. The influence of alpha activity variation of radon and its daughters on the measured results is of importance and requires a knowledge of this variation with time. Employing the measurement of alpha radiation of radon and of its short lived decay products, require knowledge of radon concentration variation and its decay products against the time. A computer program in Turbo Pascal language was therefore developed performing the computations employing the known relations involved, the program being adapted for IBM PC computers. The presented program enables computation of activity of {sup 222}Rn and its daughter products: {sup 218}Po, {sup 214}Pb, {sup 214}Bi and {sup 214}Po every 1 min within the period of 0-255 min for any state of radiation equilibrium between the radon and its daughter products. The program permits also to compute alpha activity of {sup 222}Rn + {sup 218}Po + {sup 214}Po against time and the total alpha activity at selected interval of time. The results of computations are stored on the computer hard disk in ASCII format and are used a graphic program e.g. by DrawPerfect program to make diagrams. Equations employed for computation of the alpha activity of radon and its decay products as well as the description of program functions are given. (author). 2 refs, 4 figs.

  5. H.R. 3258: This Act may be cited as the Radon Awareness and Disclosure Act of 1991, introduced in the US House of Representatives, One Hundred Second Congress, First Session, August 2, 1991

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    H.R. 3258 was introduced into the US House of Representatives to improve the accuracy of radon testing products and services, to increase testing for radon in schools, and to create a commission to provide increased public awareness of radon. Studies by the Environmental Protection Agency indicated that 54% of schools tested have at least one room with elevated levels of radon. A key feature of this act calls for the EPA, in cooperation with the Department of Health and Human Services, to implement an outreach program to provide information radon to the medical community. This information will explain the health risks of radon, and the association of radon with smoking and other causes of lung caner, and identify appropriate steps to determine exposure to radon in the home

  6. Radon in schools. Report for May 1988-September 1989

    International Nuclear Information System (INIS)

    Leovic, K.W.

    1989-01-01

    The paper discusses radon entry into schools, radon mitigation approaches for schools, and school characteristics (e.g., HVAC system design and operation) that influence radon entry and mitigation system design. It also discusses mitigation systems installed by the U.S. EPA in four schools. The primary source of radon entry into a school with significantly elevated radon levels is normally soil gas that is drawn in by pressure differentials between the soil surrounding the substructure and the building interior. If the building interior is at a lower pressure than the soil surrounding the substructure and radon is present in the soil, the radon can be pulled in through cracks and other openings that are in contact with the soil. The amount of radon in a given classroom depends on the level of radon in the underlying material, the ease with which the radon moves as a component of the soil gas through the soil, the magnitude and direction of the pressure differentials, the number and size of the radon entry routes, and dilution and mixing of the room air. HVAC systems in schools vary considerably and tend to have greater impact on pressure differentials--and consequently radon levels--than do heating and air-conditioning (HAC) systems in houses

  7. Effect of home construction on indoor radon in Virginia and Maryland

    International Nuclear Information System (INIS)

    Mushrush, G.W.; Mose, D.G.

    1988-01-01

    The levels of indoor radon in approximately 500 homes located in two contiguous counties of northern Virginia and southern Maryland have been measured during four consecutive, three month seasonal intervals using alpha-track detectors. These two counties represent an area of about 700 square miles. Results from the winter period show that the indoor radon levels were about twice as high as anticipated. In some areas, more than 50% of the homes had winter indoor radon levels above 4 pCi/liter, the EPA's recommended action level. For the spring and fall periods, indoor radon levels showed a considerable drop with approximately 35% of the homes above 4 pCi/L. Summer values were even lower with approximately 25% of the homes above 4 pCi/L.Indoor radon can be related to the weather, but home construction demonstrably determines indoor radon levels

  8. Radon risk communication research: Practical lessons

    International Nuclear Information System (INIS)

    Fisher, A.; Johnson, F.R.

    1990-01-01

    Those responsible for state and local radon programs often express frustration about the small share of homes that have been tested for radon, and the small share of those with high readings that have been mitigated. There are now a number of completed studies that have examined how well alternative ways of communicating about radon risk have accomplished the goals of motivating appropriate testing and mitigation. This paper summarizes the research results that are most crucial for planning and implementing effective radon risk communication programs. We identify six reasons why people do not respond to radon as a serious threat and provide some remedies suggested by radon studies

  9. Assessing exposure to radon in the United States: An EPA [Environmental Protection Agency] perspective

    International Nuclear Information System (INIS)

    Guimond, R.J.; Magno, P.J.

    1990-01-01

    A number of investigators have suggested that exposure to radon decay products may be a significant factor associated with the incidence of some lung cancers in the US. Various scientists have estimated that 5,000 to greater than 20,000 lung cancers per year may be attributable to radon if the average level in the US is 0.004 working levels (WL). To help assess the significance of exposure to radon across the US and within specific geographical regions, more information is needed. The paper describes efforts in the Environmental Protection Agency to assess this problem and determine the most appropriate means for dealing with risks posed by radon in new and existing housing

  10. RADON AND CARCINOGENIC RISK IN MOSCOW

    Directory of Open Access Journals (Sweden)

    S. M. Golovanev

    2015-01-01

    Full Text Available Objective: comparative evaluation of carcinogenic risk inMoscowfrom radon in indoor and atmospheric pollutants.Materials and methods: the lung cancer incidence in Moscow; radiation-hygienic passport of the territory; .U.S. EPA estimated average age at all and radon induced deaths, years of life lost; Report of UNSCEAR 2006 and WHO handbook on indoor radon, 2009. Trend analysis of incidence; evaluation of the excess relative risk; assessment of ratio radon-induced population risk and published values оf total population carcinogenic risk from chemical carcinogens.Results: it is shown that the 304 cases of lung cancer per year (1. 85 10-3 on average from 2006 to 2011 (21280diseases for 70 years in addition to background level induced by radon; the differences in average trends of all lungcancer incidence in the districts can exceed 25%.Conclusion. The potential of risk reduction by measures of mitigation radon concentration exceeds 5 times the cost efficiency to reduce emissions from vehicles and can reduce cancer incidence, on average 236 cases per year; population risk 16520 cases over 70 years or save not less than 2832 person-years of life per year. The annual effect of reducing losses from not-survival of 12 years as a result of radon-induced lung cancer deaths exceeds 14160000 dollars. The evaluating of the carcinogenic risk from radon in accordance with the definition of population risk increases the predictive evaluation of the effectiveness of preventive measures more than twice.

  11. Human perception of radon risk and radon mitigation: Some remarks

    International Nuclear Information System (INIS)

    Neznal, M.; Neznal, M.

    2008-01-01

    The Radon program in the Czech Republic has a relatively long and rich history. Procedures, which enable to evaluate the risk of radon penetration from the ground, to protect new buildings, to find existing buildings with elevated indoor radon levels and to realise remedial measures in such buildings, have been developed, published and tested. In some cases, the whole system may fail due to psychological or sociological reasons. Three types of problems (conflicts) will be presented: human behaviour affecting measurement results, conflict between individual and 'all-society' points of view, interpretation of radon risk itself. (authors)

  12. E-perm radon monitors for determining waterborne concentrations of dissolved in radon 222Rn

    International Nuclear Information System (INIS)

    Jester, W.A.; Kotrappa, P.

    1989-01-01

    This paper describes a simple and relatively inexpensive method in which E-Perm radon monitors are used to determine the concentration of dissolved 222 Rn in drinking water. This procedure takes advantage of E-Perm's ability to accurately measure the integral radon exposure under conditions of high humidity. The method was evaluated against the liquid scintillation procedure recommended by the U.S. Environmental Protection Agency (EPA) and was found to give excellent agreement. An E-perm is an electret ion chamber that consists of a small chamber constructed from a conducting plastic and having an electret at its base and a filtered air inlet at the top. The technique described in this paper takes advantages of E-Perm's insensitivity to high humidity

  13. Determination of radon in the air of housings of the Aguascalientes municipality

    International Nuclear Information System (INIS)

    Jasso G, M.R.; Lira P, M.G.; Bonilla P, A.; Ruvalcaba S, L.; Gutierrez S, K.M.; Sandoval A, G.E.; Sanchez H, L.

    2006-01-01

    This study reports the results of the first exploratory sampling of the radon concentration in the air in a group of housings of the Aguascalientes City, Mexico. The municipality of Aguascalientes was divided in 4 sampling areas considering a total of 179 housings. In these housings, the radon concentration in the air was monitored during a period of 10 days. The results obtained in this study indicate that the radon concentration in the air of 45% of the sampling housings overcomes the concentration limit of 250 Bq/m 3 suggested by the EPA. (Author)

  14. Radon: Residential attitudes toward the risk

    International Nuclear Information System (INIS)

    Fort, R.; Hinman, G.; Rosenman, R.; Wandschneider, P.

    1990-01-01

    Veradale, Washington (east of Spokane) is a region of high residential radon concentrations. Three hundred eighty residents of Veradale recently responded to a mail survey designed to elicit (1) their knowledge of and attitudes toward the risks of radon in their homes, (2) the actions they have taken or intend to take to identify and reduce those risks, and (3) policy preferences toward radon. Results reveal that these residents know that they live in an area with high radon levels, that radon causes lung cancer, and that radon will affect their health. However only 11% of respondents have had their homes tested for radon. This especially is puzzling because a large number of respondents claimed that (1) radon was important in home buying decisions, (2) they would test their own homes, (3) they would take action if such tests revealed problems, and (4) their willingness to pay for tests and improvements was well within the current costs of these actions. It remains a mystery why testing is at such a low level. Three other results are of note. First, subsidies for radon tests and home improvements may be having the unintended consequences of unneeded improvements and (potentially) moves without improvements. Second, individuals want radon testing required and results made known during home purchase decisions. Third, at present, weatherization programs that concentrate radon are acceptable to individuals. Of course, the future may hold different results. Administrators of weatherization programs, who are trusted by respondents according to this survey, would do well to institute weatherization programs with reduced radon concentrations in mind

  15. U.S. Postal Service radon assessment and mitigation program. Progress report, September 1993--November 1994

    Energy Technology Data Exchange (ETDEWEB)

    Velazquez, L.E.; Petty, J.L. Jr.

    1994-12-31

    In 1992, the US Postal Service (USPS) entered into an Interagency Agreement with the Department of Energy (DOE) whereby DOE would provide technical assistance in support of the USPS Radon Assessment and Mitigation Program. To aid in this effort, DOE tasked the Hazardous Waste Remedial Actions Program (HAZWRAP), which is managed by Martin Marietta Energy Systems, Inc., for DOE under contract AC05-84OR21400. Since that time, HAZWRAP has developed and finalized the sampling protocol, mitigation diagnostic protocol, and the quality assurance and quality control procedures. These procedures were validated during the Protocol Validation (1992-1993) and Pilot Study (1993-1994) phases of the program. To date, HAZWRAP has performed approximately 16,000 radon measurements in 250 USPS buildings. Mitigation diagnostics have been performed in 27 buildings. Thus far, 13% of the measurements have been above the Environmental Protection Agency action level of 4 pCi/L. This report summarizes the pilot program radon testing data and mitigation diagnostic data for 22 sites and contains recommendations for mitigation diagnostics.

  16. U.S. Postal Service radon assessment and mitigation program. Progress report, September 1993--November 1994

    International Nuclear Information System (INIS)

    Velazquez, L.E.; Petty, J.L. Jr.

    1994-01-01

    In 1992, the US Postal Service (USPS) entered into an Interagency Agreement with the Department of Energy (DOE) whereby DOE would provide technical assistance in support of the USPS Radon Assessment and Mitigation Program. To aid in this effort, DOE tasked the Hazardous Waste Remedial Actions Program (HAZWRAP), which is managed by Martin Marietta Energy Systems, Inc., for DOE under contract AC05-84OR21400. Since that time, HAZWRAP has developed and finalized the sampling protocol, mitigation diagnostic protocol, and the quality assurance and quality control procedures. These procedures were validated during the Protocol Validation (1992-1993) and Pilot Study (1993-1994) phases of the program. To date, HAZWRAP has performed approximately 16,000 radon measurements in 250 USPS buildings. Mitigation diagnostics have been performed in 27 buildings. Thus far, 13% of the measurements have been above the Environmental Protection Agency action level of 4 pCi/L. This report summarizes the pilot program radon testing data and mitigation diagnostic data for 22 sites and contains recommendations for mitigation diagnostics

  17. Radon reduction

    International Nuclear Information System (INIS)

    Hamilton, M.A.

    1990-01-01

    During a radon gas screening program, elevated levels of radon gas were detected in homes on Mackinac Island, Mich. Six homes on foundations with crawl spaces were selected for a research project aimed at reducing radon gas concentrations, which ranged from 12.9 to 82.3 pCi/l. Using isolation and ventilation techniques, and variations thereof, radon concentrations were reduced to less than 1 pCi/l. This paper reports that these reductions were achieved using 3.5 mil cross laminated or 10 mil high density polyethylene plastic as a barrier without sealing to the foundation or support piers, solid and/or perforated plastic pipe and mechanical fans. Wind turbines were found to be ineffective at reducing concentrations to acceptable levels. Homeowners themselves installed all materials

  18. Radon Measurements in Vojvodina

    International Nuclear Information System (INIS)

    Bikit, I.; Bikit, K.; Forkapic, S.; Mrda, D.; Nikolov, J.; Todorovic, N.; Veskovic, M.

    2013-01-01

    Recent analyses of epidemiological studies of lung cancer risk from residential exposures demonstrate a statistically significant increase per unit of exposure below average annual concentrations of about 200 Bq/m 3 . Indoor radon measurements performed in Novi Sad in about 400 houses and flats are presented and discussed in this paper. By measuring gamma-activity of radon daughters, radon activity concentration was determined to be 50 Bq/m 3 . In Vojvodina region indoor radon levels were measured by alpha track detectors CR-39 on about 3000 locations during the winter seasons in the period of three years (2003-2005). The main aim of the present study was to explore the critical group of population for radon exposure and to estimate maximal annual doses. Existing radon maps which identify regions with elevated radon levels will improve data collection and analysis for the future radon campaigns. Collaboration on the JRC program of European indoor radon map and implementation of grid system are also discussed.(author)

  19. Radon in the Gulf Coast area: Potential problem or exaggerated risk?

    International Nuclear Information System (INIS)

    Duex, T.W.

    1994-01-01

    Indoor air pollution from radon has been identified by the EPA as a serious health problem; estimates indicate that radon is the second leading cause of lung cancer (after smoking) and that high levels of radon may cause as many as 20,000 to 40,000 lung cancer deaths per year in the United States. Studies of the potential risk in the Gulf Coast have been sparse. This report summarizes over 7000 previously unreported radon analyses and relates them to geological information to identify possible problem areas for the Gulf Coast region of Louisiana, Texas, Mississippi, Alabama, and Florida. High levels of indoor radon are generally associated with older open-quotes crystallineclose quotes igneous and metamorphic bedrock; thus, most areas of the Gulf Coast are of relatively low risk because they are underlain by Cenozoic sedimentary rocks and unconsolidated deposits. However, some types of sedimentary deposits, such as open-quotes black shaleclose quotes and phosphate-rich rocks, can underlie areas of high risk. According to EPA indoor radon survey results the percentage of houses with screening levels greater than 4 pCi/1 (picocuries per liter) for given states is as follows: Alabama = 0.6%, Louisiana = 0.8%, Mississippi = 2.0%, and Texas = 4.0% (no data available for Florida). The data presented here for the percentage of houses with greater than 4 pCi/1 for given states is as follows: Alabama = 6.1 %, Louisiana = 0.6%, Mississippi = 2.0%, Texas = 1.6%, and Florida = 4.5%. The areas that appear to have the greatest risk are parts of northern Alabama and Mississippi, central Texas, and some areas in Florida

  20. Cost-effectiveness analysis of public education and incentive programs for controlling radon in the home. Final report

    International Nuclear Information System (INIS)

    Bierma, T.J.; Swartzman, D.

    1988-12-01

    The objective of this study was to evaluate the cost-effectiveness in Illinois of five radon public education and incentive program options. Programs evaluated included (1) no program, (2) a toll-free hotline and information packet, (3) free short-term monitors, (4) free confirmatory monitors, and (5) low-interest loans. Existing literature and expert opinion were used to estimate program costs and public responses under the various programs. Computer simulation, with Monte Carlo sampling, was used for uncertainty and sensitivity analysis. The cost-effectiveness model was analyzed based on assumed radon exposures to Illinois citizens. Results for standard conditions indicate that budget levels under approximately $30,000 do not warrant a radon education and incentive program. For budget levels of approximately $30,000 to $1 million, Program 2 was most effective, and Program 3 was most effective above this level. Sensitivity analyses indicate the results are relatively insensitive to input variable assumptions with the exception of public-response estimates. Study results suggest that all of the programs evaluated are likely to be relatively ineffective. Considerable improvement may be possible using more innovative approaches to public education

  1. EPA perspective on radionuclide aerosol sampling

    Energy Technology Data Exchange (ETDEWEB)

    Karhnak, J.M. [Environmental Protection Agency, Washington, DC (United States)

    1995-02-01

    The Environmental Protection Agency (EPA) is concerned with radionuclide aerosol sampling primarily at Department of Energy (DOE) facilities in order to insure compliance with national air emission standards, known as NESHAPs. Sampling procedures are specified in {open_quotes}National Emission Standards for Emissions of Radionuclides other than Radon from Department of Energy Sites{close_quotes} (Subpart H). Subpart H also allows alternate procedures to be used if they meet certain requirements. This paper discusses some of the mission differences between EPA and Doe and how these differences are reflected in decisions that are made. It then describes how the EPA develops standards, considers alternate sampling procedures, and lists suggestions to speed up the review and acceptance process for alternate procedures. The paper concludes with a discussion of the process for delegation of Radionuclide NESHAPs responsibilities to the States, and responsibilities that could be retained by EPA.

  2. Radon gas exposure levels in some selected areas in Egypt

    International Nuclear Information System (INIS)

    Ali, E.M.; Taha, T.M.; Gomaa, M.A.; El-Hussein, A.M.; Ahmed, A.A.

    2005-01-01

    During a summer season of 2003, the atmospheric concentrations of radon gas were measured indoor every one-hour for twenty-four hour measurements in some selected areas, using Pylon-AB4. Two hundreds and forty samples were monitored to determine the concentration of radon gas at each location using high-efficiency Lucas type continuous passive cell. The average values of radon gas concentration were taken in three time intervals 6.00:18.00, 18.00:6.00 and whole day. The average values of indoor radon gas of two locations using three time intervals were 4.82±0.63, 9±0.71 and 6.9±0.33 and 9.6±0.23, 11.82±0.42 and 9.37±0.7 Bq/m /h. respectively. The exposure levels were within the ICRP and EPA recommendations

  3. Cost and effectiveness of radon-resistant features in new school buildings

    International Nuclear Information System (INIS)

    Craig, A.B.; Leovic, K.W.; Saum, D.W.

    1991-01-01

    Recent concerns over elevated levels of radon in existing buildings have prompted the design and construction of a number of school buildings that either are radon resistant or incorporate features that facilitate post-construction mitigation if needed. This paper describes initial results of a study of several schools with radon-resistant features that were recently constructed in the northeastern US. These designs are generally based on experience with radon mitigation in existing houses and schools and radon-resistant new house construction. The study was limited to slab-on-grade schools, where the most common radon-resistant school design is active subslab depressurization (ASD). The additional construction costs for eight schools built with ASD ranged from $3 to $11 per square meter of slab area. The radon contractors who designed these systems have tended to overdesign the radon-reduction systems in the absence of specific written guidance to follow to lessen potential liability in the event of system failure. Design features include detailed sealing of all stab cracks, multiple exhaust stacks, and extensive subslab piping. Recent Environmental Protection Agency (EPA) research on radon mitigation suggests that simpler ASD systems may provide sufficient radon resistance in new large buildings at lower costs. Components of a specification for radon-resistant school construction are discussed, based on comments from radon system designers. Another school being studied was built with a heating, ventilating, and air-conditioning (HVAC) pressurization radon control system, and considerations for this type of system are examined

  4. 48 CFR 1552.219-71 - Procedures for Participation in the EPA Mentor-Protege Program.

    Science.gov (United States)

    2010-10-01

    ... Participation in the EPA Mentor-Protege Program. 1552.219-71 Section 1552.219-71 Federal Acquisition Regulations... Texts of Provisions and Clauses 1552.219-71 Procedures for Participation in the EPA Mentor-Protege... EPA Mentor-Protege Program (OCT 2000) (a) This provision sets forth the procedures for participation...

  5. Study of temporal variation of radon concentrations in public drinking water supplies

    International Nuclear Information System (INIS)

    York, E.L.

    1995-01-01

    The Environmental Protection Agency (EPA) has proposed a Maximum Contaminant Level (MCL) for radon-222 in public drinking water supplies of 300 pCi/L. Proposed monitoring requirements include collecting quarterly grab samples for the first year, then annual samples for the remainder of the compliance cycle provided first year quarterly samples average below the MCL. The focus of this research was to study the temporal variation of groundwater radon concentrations to investigate how reliably one can predict an annual average radon concentration based on the results of grab samples. Using a open-quotes slow-flowclose quotes collection method and liquid scintillation analysis, biweekly water samples were taken from ten public water supply wells in North Carolina (6 month - 11 month sampling periods). Based on study results, temporal variations exist in groundwater radon concentrations. Statistical analysis performed on the data indicates that grab samples taken from each of the ten wells during the study period would exhibit groundwater radon concentrations within 30% of their average radon concentration

  6. Radon Concentration in Groundwater in the Central Region of Gyeongju, Korea - 13130

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Min; Lee, A. Rim; Park, Chan Hee; Moon, Joo Hyun [Dongguk University, Seokjangdong, Gyeongju, Gyeongbuk, 780-714 (Korea, Republic of)

    2013-07-01

    Radon is a naturally occurring radioactive gas that is a well known cause of lung cancer through inhalation. Nevertheless, stomach cancer can also occur if radon-containing water is ingested. This study measured the radon concentration in groundwater for drinking or other domestic uses in the central region of Gyeongju, Korea. The groundwater samples were taken from 11 points chosen from the 11 administrative districts in the central region of Gyeongju by selecting a point per district considering the demographic distribution including the number of tourists who visit the ancient ruins and archaeological sites. The mean radon concentrations in the groundwater samples ranged from 14.38 to 9050.73 Bq.m{sup -3}, which were below the recommendations by the U.S. EPA and WHO. (authors)

  7. EML indoor radon workshop, 1982

    International Nuclear Information System (INIS)

    George, A.C.; Lowder, W.; Fisenne, I.; Knutson, E.O.; Hinchliffe, L.

    1983-07-01

    A workshop on indoor radon, held at the Environmental Measurements Laboratory (EML) on November 30 and December 1, 1982, covered recent developments in radon daughter research and development. Thirty papers were presented dealing with standardization and quality assurance measurement methods, surveys, measurements strategy, physical mechanisms of radon and radon daughter transport and development of guidance standards for indoor exposures. The workshop concluded with a planning session that identified the following needs: (1) national and international intercomparisons of techniques for measuring radon and radon daughter concentrations, working level and radon exhalation flux density; (2) development and refinement of practical measurement techniques for thoron and its daughter products; (3) quantitative definition of the sources of indoor radon and the mechanisms of transport into structures; (4) better knowledge of the physical properties of radon daughters; (5) more complete and accurate data on the population exposure to radon, which can only be met by broadly based surveys; and (6) more international cooperation and information exchange among countries with major research programs

  8. Assessment of health impacts of radon exposures in Florida

    International Nuclear Information System (INIS)

    Vonstille, W.T.; Sacarello, H.L.A.

    1990-01-01

    This paper reports on residential radon levels, from a statewide Florida survey, that were used in an analysis of over 150,000 medically treated episodes of malignancies and other serious illnesses and conditions in whites, blacks and Hispanics from all counties in the state. No evidence of an increased percentage of cancer was found in any sex or ethnic group from the areas with the highest radon exposure levels. Age adjustment of data did not affect the results. The highest radon exposures were associated with some of the lowest cancer rates and contradict the risk assessment hypothesis based on extrapolation from exposures in mining. Points for DOE and EPA errors in risk assessment methods are reviewed; predictions from risk assessment should be empirically tested as in the case of any other scientific hypothesis before being used as a basis for public policy. Thus, the authors find that cancer risks of residential radon have been vastly overstated

  9. Uranium distribution and radon exhalation from Brazilian dimension stones

    International Nuclear Information System (INIS)

    Amaral, P.G.Q.; Galembeck, T.M.B.; Bonotto, D.M.; Artur, A.C.

    2012-01-01

    This paper provides evaluations of the radiometric behavior and exhalation patterns of radon gas in decorative and dimension stones explored in the Brazilian states of Minas Gerais and Espírito Santo, given the importance of determining radon gas concentrations in human-inhabited environments. A total of 10 silicate rock types were studied, featuring different petrographic/petrophysical characteristics given by seven magmatic rocks (three of which are granitic pegmatites) and three metamorphic rocks. The study, comprising radiometric data of U and monitoring of 222 Rn gas exhalation, shows a strong correlation between petrographic parameters and the physical properties of rocks. U levels ranged between 2.9 and 37 ppm, revealing a good coherence between the presence and the absence of radioactive element-bearing accessory minerals for each rock type. The rate of radon exhalation from the stones is related to the petrographic/petrophysical features of each material. By comparing the 222 Rn level generated by a rock to the amount effectively emanated by it, the rate of emanated gas proves to be insignificant; also, a rock that produces more Rn will not always emanate more. Simulations performed to estimate the radon levels inside residences or any given indoor environment showed that nine samples attained values below the 4 pCi/L EPA limit, whereas one was above that limit. - Highlights: ► Integration of distinct radiometric data acquired in dimension stones. ► Dimension stones are extensively commercialized abroad. ► Rn exhalation above the EPA threshold limit of 4 pCi/L.

  10. Uranium distribution and radon exhalation from Brazilian dimension stones

    Energy Technology Data Exchange (ETDEWEB)

    Amaral, P.G.Q.; Galembeck, T.M.B. [Departamento de Petrologia e Metalogenia, Instituto de Geociencias e Ciencias Exatas, Universidade Estadual Paulista (UNESP), Av. 24-A No. 1515, C.P. 178, CEP 13506-900, Rio Claro, Sao Paulo (Brazil); Bonotto, D.M., E-mail: danielbonotto@yahoo.com.br [Departamento de Petrologia e Metalogenia, Instituto de Geociencias e Ciencias Exatas, Universidade Estadual Paulista (UNESP), Av. 24-A No. 1515, C.P. 178, CEP 13506-900, Rio Claro, Sao Paulo (Brazil); Artur, A.C. [Departamento de Petrologia e Metalogenia, Instituto de Geociencias e Ciencias Exatas, Universidade Estadual Paulista (UNESP), Av. 24-A No. 1515, C.P. 178, CEP 13506-900, Rio Claro, Sao Paulo (Brazil)

    2012-04-15

    This paper provides evaluations of the radiometric behavior and exhalation patterns of radon gas in decorative and dimension stones explored in the Brazilian states of Minas Gerais and Espirito Santo, given the importance of determining radon gas concentrations in human-inhabited environments. A total of 10 silicate rock types were studied, featuring different petrographic/petrophysical characteristics given by seven magmatic rocks (three of which are granitic pegmatites) and three metamorphic rocks. The study, comprising radiometric data of U and monitoring of {sup 222}Rn gas exhalation, shows a strong correlation between petrographic parameters and the physical properties of rocks. U levels ranged between 2.9 and 37 ppm, revealing a good coherence between the presence and the absence of radioactive element-bearing accessory minerals for each rock type. The rate of radon exhalation from the stones is related to the petrographic/petrophysical features of each material. By comparing the {sup 222}Rn level generated by a rock to the amount effectively emanated by it, the rate of emanated gas proves to be insignificant; also, a rock that produces more Rn will not always emanate more. Simulations performed to estimate the radon levels inside residences or any given indoor environment showed that nine samples attained values below the 4 pCi/L EPA limit, whereas one was above that limit. - Highlights: Black-Right-Pointing-Pointer Integration of distinct radiometric data acquired in dimension stones. Black-Right-Pointing-Pointer Dimension stones are extensively commercialized abroad. Black-Right-Pointing-Pointer Rn exhalation above the EPA threshold limit of 4 pCi/L.

  11. Environmental assessment of indoor radon gas exposure health hazards and some of its public risks

    International Nuclear Information System (INIS)

    Hussein, Abd El-Razik. Z.; Ibrahim, M.Se.; Ragab, M.H.; El-Bukhari, M.S.

    2005-01-01

    This study examine the relationship between indoor radon gas exposure and the cancer risk and housing characteristics in lung cancer risk houses (CRH) compared to non lung cancer risk houses (NCRH). Mean radon concentrations measured by active method were significantly higher among CRH compared to NCRH, 9:93 pCi/L versus 4.56 pCi/L, respectively. There was no statistically significant diurnal variation as regards radon levels in all examined houses. Indoor radon concentrations show statistically significance in houses with bad ventilation (low air change rate) compared to houses with good ventilation (high air change rate). Houses with floor material of tiles, had statistically significant higher radon concentrations. Neither finishing wall material nor indoor gas source shows statistically significance as regard radon levels. Radon levels > 4 pCi/L (US EPA action level) were statistically significance higher in bed rooms compared levels in living rooms. High radon concentrations were reported in lung cane risk houses and in houses with bad ventilation

  12. Overview of the EPA quality system for environmental programs

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, G.L. [Environmental Protection Agency, Research Triangle Park, NC (United States)

    1993-12-31

    Formalized quality assurance program requirements for the U.S. Environmental Protection Agency (EPA) have been established for more than a decade. During this period, the environmental issues and concerns addressed by the EPA have changed. Many issues, such as ozone depletion and global climate warming, have become international concerns among the world environmental community. Other issues, such as hazardous waste cleanup and clean air, remain a focus of national environmental concerns. As the environmental issues of the 1980`s evolved, the traditional quality assurance (QA) program was transformed through the use of quality management principles into a Quality System to help managers meet the needs of the 1990`s and beyond.

  13. Overview of the EPA quality system for environmental programs

    International Nuclear Information System (INIS)

    Johnson, G.L.

    1993-01-01

    Formalized quality assurance program requirements for the U.S. Environmental Protection Agency (EPA) have been established for more than a decade. During this period, the environmental issues and concerns addressed by the EPA have changed. Many issues, such as ozone depletion and global climate warming, have become international concerns among the world environmental community. Other issues, such as hazardous waste cleanup and clean air, remain a focus of national environmental concerns. As the environmental issues of the 1980's evolved, the traditional quality assurance (QA) program was transformed through the use of quality management principles into a Quality System to help managers meet the needs of the 1990's and beyond

  14. Determination of radon concentration in drinking water resources of villages nearby Lalehzar fault and evaluation the annual effective dose

    International Nuclear Information System (INIS)

    Mohammad Malakootian; Zahra Darabi Fard; Mojtaba Rahimi

    2015-01-01

    The radon concentration has been measured in 44 drinking water resources, in villages nearby Lalehzar fault in winter 2014. Some samples showed a higher concentration of radon surpassing limit set by EPA. Further, a sample was taken from water distribution networks for these sources of water. Soluble radon concentration was measured by RAD7 device. Range radon concentration was 26.88 and 0.74 BqL -1 respectively. The maximum and minimum annual effective dose for adults was estimated at 52.7 and 2.29 µSvY -1 , respectively. Reducing radon from water before use is recommended to improve public health. (author)

  15. Human Lung Cancer Risks from Radon – Part III - Evidence of Influence of Combined Bystander and Adaptive Response Effects on Radon Case-Control Studies - A Microdose Analysis

    Science.gov (United States)

    Leonard, Bobby E.; Thompson, Richard E.; Beecher, Georgia C.

    2012-01-01

    Since the publication of the BEIR VI (1999) report on health risks from radon, a significant amount of new data has been published showing various mechanisms that may affect the ultimate assessment of radon as a carcinogen, in particular the potentially deleterious Bystander Effect (BE) and the potentially beneficial Adaptive Response radio-protection (AR). The case-control radon lung cancer risk data of the pooled 13 European countries radon study (Darby et al 2005, 2006) and the 8 North American pooled study (Krewski et al 2005, 2006) have been evaluated. The large variation in the odds ratios of lung cancer from radon risk is reconciled, based on the large variation in geological and ecological conditions and variation in the degree of adaptive response radio-protection against the bystander effect induced lung damage. The analysis clearly shows Bystander Effect radon lung cancer induction and Adaptive Response reduction in lung cancer in some geographical regions. It is estimated that for radon levels up to about 400 Bq m−3 there is about a 30% probability that no human lung cancer risk from radon will be experienced and a 20% probability that the risk is below the zero-radon, endogenic spontaneous or perhaps even genetically inheritable lung cancer risk rate. The BEIR VI (1999) and EPA (2003) estimates of human lung cancer deaths from radon are most likely significantly excessive. The assumption of linearity of risk, by the Linear No-Threshold Model, with increasing radon exposure is invalid. PMID:22942874

  16. Radon: Gas transport in soils and its relation to radon availability: Hot spot identification and flow characteristics near structures. Progress report and request for third year incremental funding

    International Nuclear Information System (INIS)

    Reimer, G.M.

    1995-01-01

    There are 3 major objectives being addressed in this research. The first is to participate, by providing ground truth quality assurance, in the DOE/LBL/EPA cooperative study to determine a methodology to predict the areas where indoor radon concentrations have the highest probability of exceeding 20 pCi/L (750 Bq/m 3 ). The second is to examine 2 common types of homes (basement and non-basement) for radon entry by monitoring specific parameters under normal living conditions. The third task is to participate with other researchers in their studies using the techniques and experience developed by this principal investigator during previously funded times. Those researchers seek assistance in measuring soil permeability, determining the effect of meteorological parameters on radon entry, determining the diffusion characteristics of standard basement wall materials, developing a GIS (Geographic Information System) data base for predicting regional radon potential, and examining the contribution of regional solution-developed permeability in limestone to the radon potential of an area

  17. Radon mapping - Santa Barbara and Ventura counties

    International Nuclear Information System (INIS)

    Churchill, R.

    1997-01-01

    Since 1990, the Department of Conservation''s Division of Mines and Geology (DMG) has provided geologic information and conducted several research projects on geology and radon for the California Department of Health Services (DHS) Radon Program. This article provides a brief overview of radon''s occurrence and impact on human health, and summarizes a recent DMG project for DHS that used geologic, geochemical, and indoor radon measurement data to produce detailed radon potential zone maps for Santa Barbara and Ventura counties

  18. Indoor radon concentration data: Its geographic and geologic distribution, an example from the Capital District, NY

    International Nuclear Information System (INIS)

    Thomas, J.J.; Overeynder, H.M.; Thomas, B.R.

    1995-01-01

    Most studies of the geographic distribution of indoor radon levels are plotted by county or ZIP code. This method is used for the radon potential maps produced by the U.S. Environmental Protection Agency (EPA) and the New York State Department of Health (NYSDOH). The basis for the mapping is the mean or median indoor radon count for all the data provided by NYSDOH within each geographic area. While testing the indoor radon analyses provided to the authors by CMT Independent Laboratories, we discovered data that deviated markedly from the EPA and NYSDOH means for the Capital District of New York (Albany and surrounding counties). Their screening indoor radon average concentrations in pCi/L, indicate low potential for Schenectady (3.0), Saratoga (3.2), and Albany (3.7) counties; and moderate potential for Rensselaer (6.4) and Columbia (7.0) counties. Our database of over 3,000 analyses contains over 800 records of indoor radon counts above 4 pCi/L (14-47% of each county's analyses), many high enough to be rated as a serious health hazard. In order to obtain greater precision of information, the authors plotted their indoor radon data by street address using MapInfo, a geographic Information System (GIS), and StreetInfo, MapInfo's TIGER address database. We compared the geographic distribution of our data to both the Bedrock Geology and Surficial Geology Maps of New York State. The results show a striking relationship of radon concentrations to bedrock, faults and permeability of surficial material. Data being compiled and mapped by street address by the NYSDOH in Erie County in western New York, confirm our results

  19. Evaluation of the performance characteristics of radon and radon-daughter concentration measurement devices under controlled environmental conditions

    International Nuclear Information System (INIS)

    Pearson, M.D.

    1989-04-01

    The Technical Measurements Center (TMC) conducted a study to expose 10 radon and 7 radon-daughter concentration measurement devices in the DOE/GJPO Radon/Radon-Daughter Environmental Chamber for a series of 24 controlled-environment tests. The tests evaluated the devices' response to temperature, relative humidity, dew point, condensation-nuclei concentration, radon-daughter/radon equilibrium ratio, and non-uniform radon and radon-daughter concentration. Devices were evaluated for linear response as a function of concentration. In addition to response to environmental parameters, the evaluation included determining the utility of the devices in providing reasonable assurance of compliance with the radon and radon-daughter concentration standards for DOE remedial action programs. This reasonable assurance criterion is based on a coefficient of variation of 25 percent for devices deployed for year-long measurements and a coefficient of variation of 18 percent for devices deployed for intermittent sampling. 39 refs., 65 figs., 33 tabs

  20. NORM and radon in Austria. Status and strategy; Norm und Radon in Oesterreich. Status und Strategie

    Energy Technology Data Exchange (ETDEWEB)

    Maringer, F.J. [Bundesamt fuer Eich- und Vermessungswesen, Wien (Austria)

    2013-07-01

    The author reviews the actual radiation protection practice in Austria for NORM and radon, including possible strategies and developments. Specific topics are radiation protection technologies, metrological resources for NORM in Austria, civil engineering standards (OeNORM) for radon measurement, radon prevention for new buildings and radon cleansing for existing buildings, future assessment and legal regulation of radioactivity in construction materials. The strategic development in Austria considers the current European standard projects (EU standards) and European and international research programs.

  1. Canadian individual risks of radon-induced lung cancer for different exposure profiles.

    Science.gov (United States)

    Chen, Jing

    2005-01-01

    Indoor radon has been determined to be the second leading cause of lung cancer after tobacco smoking. There is an increasing need among radiation practitioners to have numerical values of lung cancer risks for men and women, ever-smokers and never-smokers exposed to radon in homes. This study evaluates individual risks for the Canadian population exposed to radon in homes at different radon concentrations and for different periods of their lives. Based on the risk model developed recently by U.S. Environmental Protection Agency (EPA), individual risks of radon-induced lung cancers are calculated with Canadian age-specific rates for overall and lung cancer mortalities (1996-2000) as well as the Canadian smoking prevalence data in 2002. Convenient tables of lifetime relative risks are constructed for lifetime exposures and short exposures between any two age intervals from 0 to 110, and for various radon concentrations found in homes from 50 to 1000 Bq/m3. The risk of developing lung cancer from residential radon exposure increases with radon concentration and exposure duration. For short exposure periods, such as 10 or 20 years, risks are higher in middle age groups (30-50) compared especially to the later years. Individuals could lower their risks significantly by reducing radon levels earlier in life. The tables could help radiation protection practitioners to better communicate indoor radon risk to members of the public.

  2. Assessment of lung cancer risk from radon in five provinces of Iran

    International Nuclear Information System (INIS)

    Baradaran, S.; Taheri, M.; Setayeshi, S.

    2010-01-01

    Radon is a natural radioactive gas which is produced by decay of the Uranium and emanates from the ground. According to EPA and WHO studies, Radon is the second largest cause of lung cancer after smoking. According to the registered information report of cancer cases from 1985 till now, lung cancer is the second most common death cause in all cancers (after stomach cancer) in Iran. Based on the report of the National Institute of Cancer and the Iranian Ministry of Health, the total death due to lung cancer were estimated to be 5.7%, 4.82%, 4.48% 3.76%, 9% in mentioned provinces. An investigation was made on the relation between lung cancer risk and radon levels. The risk for smoking, the first leading cause of lung cancer, is more greater than for radon, the second leading cause. The results show that there is no direct relation between increased risk of lung cancer from indoor radon exposure, but it cannot be ignored that indoor radon should be considered as a cause of lung cancer in the general population

  3. High Radon Areas and lung cancer prevalence: Evidence from Ireland.

    Science.gov (United States)

    Dempsey, Seraphim; Lyons, Seán; Nolan, Anne

    2018-02-01

    This paper examined the relationship between radon risk and lung cancer prevalence using a novel dataset combining spatially-coded survey data with a radon risk map. A logit model was employed to test for significant associations between a high risk of indoor radon and lung cancer prevalence using data on 5590 people aged 50+ from The Irish Longitudinal Study on Ageing (TILDA) and radon risk data from Ireland's Environmental Protection Agency (EPA). The use of data at the individual level allowed a wide range of potentially confounding factors (such as smoking) to be included. Results indicate that those who lived in an area in which 10%-20% of households were above the national reference level (200 Bq/m 3 ) were 2.9-3.1 times more likely to report a lung cancer diagnosis relative to those who lived in areas in which less than 1% of households were above the national reference level. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. The future of the radon program in the Czech Republic : the problems and challenges from the regulatory point of view

    International Nuclear Information System (INIS)

    Petrova, Karla

    2008-01-01

    Recently the radon program in the Czech Republic is running under the governmental resolution adopted in 1999 for 10 years. During the 2008 year a new national strategy for the further long term management of the radon issue should be proposed to the government. Taking into account the experience from the preceding years and particularly the effectiveness of the running radon program the proposal which is now in preparation is more focused to the prevention in new houses and to the more qualified, understandable information distribution within the population. The current initiatives of E U concerning the natural exposure regulation within the recast process of the European legislation related to the radiation protection are also reflected as far as possible at the moment. The principal points of the decision making process and the highlights of the proposal for a new national radon program in the Czech Republic are given in the paper. (author)

  5. The role of the EPA radiation quality assurance program in the measurement quality assurance accreditation program for radioassay laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Grady, T.M. [Environmental Monitoring Systems Laboratory, Las Vegas, NV (United States)

    1993-12-31

    As the nature and extent of radiological contamination becomes better documented and more public, radioanalytical laboratories are faced with a constantly expanding variety of new and difficult analytical requirements. Concurrent with those requirements is the responsibility to provide customers, regulatory officials, or the public with defensible data produced in an environment of verifiable, controlled quality. To meet that need, a quality assurance accreditation program for radioassay laboratories has been proposed by the American National Standards Institute (ANSI). The standard will provide the organizational framework and functional requirements needed to assure the quality of laboratory outputs. Under the proposed program, the U.S. Environmental Protection Agency`s (EPA`s) Laboratory Intercomparison Program plays a key role as a reference laboratory. The current and proposed roles of the EPA Intercomparison Program are discussed, as are the functional relationships between EPA, the accreditating organization, and the service and monitoring laboratories.

  6. Radon survey in Metropolitan Toronto schools

    International Nuclear Information System (INIS)

    Becker, E.; Moridi, R.

    1992-01-01

    The radon testing survey in Metropolitan Toronto public schools was the most intensive project of its kind ever undertaken in Canadian schools. It also included an extensive public education program on radiation and radon-in-schools. The radon levels at 632 schools were measured using the CAIRS Radon Monitors. Ninety percent of the locations measured were found to have a radon level equal to or less than 2 mWL. Two locations in two different schools were found to have a radon level at or above the Action Level (20 mWL). The remaining results were between the two extremes. Follow-up testing in those schools where more than 10 mWL of radon was found is in progress. (author)

  7. Long term indoor radon measurements in the pelletron laboratory at the UNAM physics institute

    International Nuclear Information System (INIS)

    Espinosa, G.; Golzarri, J. I.; Lopez, K.; Rickards, J.

    2011-01-01

    The results of six months of continuous measurement of the indoor radon concentration levels in the building where the Physics Institute 3 MV Pelletron particle accelerator is located are presented. This study has three major objectives: a) to know the actual values of the levels of indoor radon in this installation, where personnel spend many hours and sometimes days; b) assess the radiological risk from radon inhalation for personnel working permanently in the laboratory, as well as incidental users; and c) establish, if necessary, time limits for continuous permanence on the location for indoor radon exposure. Passive nuclear track detectors and dynamic systems were employed, covering six months (August, 2009 to January, 2010). For the calculation of internal dose the Radon Individual Dose Calculator was used. The results indicate that the indoor radon levels are below the US EPA recommended levels (400 Bq/m 3 ) in workplaces. The measurements help to establish levels for workplaces in Mexico. (Author)

  8. Research on radon flux reduction from uranium mill tailings

    International Nuclear Information System (INIS)

    Overmyer, R.F.; Thamer, B.J.; Nielson, K.K.; Rogers, V.C.

    1980-01-01

    Radon flux reduction from tailings may be accomplished by the use of an impermeable cover to contain the radon until it decays (half life is 2.8 days). The use of a thick, relatively impermeable cover can attenuate radon flux because a large fraction of the radon would decay before it diffuses through the cover into the atmosphere. This method of reducing radon flux may require soil cover thicknesses on the order of 10 feet. In some locations, obtaining 10 feet of soil to cover 200 acres of tailings may be difficult or may lead to other significant environmental impacts. The Department of Energy is sponsoring research to identify alternatives to thick soil covers for reducing radon flux from uranium tailings to meet the forthcoming standards. The two most effective and practical materials tested thus far are Calcilox and asphalt emulsion. Currently, asphalt emulsions are being tested at the Grand Junction tailings pile in Grand Junction, Colorado, by Battelle Pacific Northwest Laboratory. Other asphalt formulations, such as foamed asphalt that requires less water than asphalt emulsions, may be practical and will be tested this year. Some sulfur-based materials and sulfur-extended asphalt also appear promising and will be tested for effectiveness in reducing radon flux. It is also important to investigate methods of applying various stabilizers to inactive tailings piles in various physical conditions of moisture content, and physical stability. Finally, since the EPA standards for remedial action at tailings piles are stated in terms of radon flux, it is important that radon flux measurements be standardized so that reliable flux measurements can be obtained and directly compared among various laboratories

  9. Measurement of radon in Spanish houses: characterization of its sources

    International Nuclear Information System (INIS)

    1998-01-01

    The determination of radon concentrations in-house are analyzed by different universities. The programs of Cantabria, Valencia, Barcelona and La Laguna Universities are presented. These programs study the environmental impact of radon in Barcelona and Madrid and characterize the radon sources

  10. Indoor radon II

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Because of the growing interest in and public concern about indoor radon, APCA, in April 1987, sponsored the Second International Specialty Conference on Indoor Radon. This book is the proceedings of this conference and includes discussions on: A current assessment of the nature of the problem; Issues related to health effects and risk assessment; The development of public and private sector initiatives; Research into methods of control and prevention; International perspectives; and Measurement methods and programs. The material is intended for the technically oriented and for those responsible for developing programs and initiatives to address this important public health issue. Contributors include federal, state, and provincial program officials and members of the academic and private sectors

  11. Standardization of radon measurements

    International Nuclear Information System (INIS)

    Matuszek, J.M.; Hutchinson, J.A.; Lance, B.H.; Virgil, M.G.; Mahoney, R.J.

    1988-01-01

    Radon escaping from soil into homes appears to present the single greatest source of radiation exposure that most people will ever face. Measurement protocols for the relatively inert gas inextricably link the method of collection with the counting of the specimen. The most commonly used methods depend on the measurement of dislocation sites on plastic α-track detectors or on the adsorption of radon onto activated charcoal for subsequent counting of the γ-rays produced by decay of the radon progeny. The uncertainties inherent to the radon-measurement methods used commercially in the United States are far greater than those for measurements of other environmental radionuclides. The results of this preliminary study raise doubts as to whether existing proficiency-testing programs can provide assurance that radon-measurement methods are representative of actual conditions in any dwelling. 17 refs., 1 figs., 4 tabs

  12. Radon: Chemical and physical states of radon progeny. Final technical report

    International Nuclear Information System (INIS)

    Castleman, A.W. Jr.

    1996-01-01

    The evolving chemical and physical form of radon progeny influence their transport to the bioreceptor and the extent to which that receptor can take up these species into various tissues. When first born following radioactive decay processes, the potentially deleterious radon progeny undergo various physical and chemical transformations as they transcend from a highly charged to a neutral state, and interact with various constituents of the environment. These transformations impact on the extent to which the radon progeny become associated with aerosol particles on the one hand, and their ultimate chemical form that is available for uptake in the biosystem, on the other. The program, which originally commenced in 1987, dealt with the basic chemistry and physics of radon progeny and hence impacted on several themes of importance to the DOE/OHER radon program. One of these is dose response, which is governed by the physical forms of the radon progeny, their transport to the bioreceptor and the chemical forms that govern their uptake. The second theme had to do with cellular responses, one of the major issues motivating the work. It is well known that various sizes of ions and molecules are selectively transported across cell membrane to differing degrees. This ultimately has to do with their chemical and physical forms, charge and size. The overall objective of the work was threefold: (1) quantifying the mechanisms and rates of the chemical and physical transformation; (2) ascertaining the ultimate chemical forms, and (3) determining the potential interactions of these chemical species with biological functional groups to ascertain their ultimate transport and incorporation within cells

  13. Swiss radon programme 'RAPROS'

    International Nuclear Information System (INIS)

    Zeller, W.

    1992-03-01

    The results of the five-year radon research program RAPROS presented in this report, allow for scientifically valid statements on the origin of elevated levels of indoor radon in Switzerland. These results form a basis for recommendations and for actions to be taken. Indoor radon concentrations have been measured in more than 4000 living-rooms and 2000 basements; a sampling density of about 0.2% of the Swiss housing stock. According to these measurements radon leads to an estimated average annual effective dose of 2 milli-Sievert, although in some regions the annual dose may be much higher. Extrapolation of the existing data shows that in about 10'000 Swiss houses radon may exceed 1000 Bq/m 3 . For these houses remedial actions are recommended. There seems to be no radon problem in the large cities in the Swiss Plateau. High indoor radon concentrations in Switzerland are due to the soil beneath the buildings. Data from the study indicated that the most important soil characteristic influencing indoor radon concentrations was its gas permeability. Because natural ventilation in a heated house creates a slight underpressure in the lower levels with respect to surrounding soils, radon is driven from the soil into the building. Weatherization of the houses to reduce energy consumption had in most cases no effect on the indoor radon concentrations. Radon from tap water or from building materials does not contribute significantly to indoor radon levels in Switzerland. The high levels in the Jura Mountains are thought to be associated with karstic limestone bedrock. Several houses within Switzerland have now been modified to reduce radon levels. The most successful mitigation technique combined forced-air ventilation with tightening of the basement to decrease or prevent air infiltration from the soil. (author) figs., tabs., refs

  14. World Health Organization's International Radon Project 2005-2008

    International Nuclear Information System (INIS)

    Carr, Zhanat; Shannoun, Ferid; Zielinski, Jan M.

    2008-01-01

    Recent epidemiological studies of people exposed to indoor radon have confirmed that radon in homes is a serious health hazard that can be easily mitigated. To address the issue at an international level, the World Health Organization (WHO) established the International Radon Project (IRP). The project was launched in January 2005 with its first meeting attended by 36 experts representing 17 countries. The project's scope and the key objectives were outlined at this meeting and later refined: 1-) To identify effective strategies for reducing the health impact of radon; 2-) To promote sound policy options, prevention and mitigation programs (including monitoring and evaluation of programs; 3-) To raise public, political and economical awareness about the consequences of exposure to radon (including financial institutions as target group); 4-) To estimate the global health impact of exposure to residential radon using available data on radon worldwide. WHO and its member states strive through the WHO-IRP to succeed in putting indoor radon on the environmental health agenda in countries with lower awareness of radon as a health problem and in strengthening local and national radon-related activities in countries with ongoing radon programs. Two subsequent working meetings were held: in March, 2006 in Geneva with 63 participants from 25 countries, along with representatives of the International Atomic Energy Agency (IAEA), the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), the International Commission on Radiological Protection (ICRP), and European Commission (EC); and in March 2007 in Munich with 61 participants from 27 countries. Both meetings reviewed the IRP progress and focused on the two main outputs: 'The WHO Report on the Global Burden of Disease (GBD) due to Radon' and 'The WHO Radon Handbook'. The former applies the WHO methodology for GBD assessment and considers ways to graphically map residential radon concentrations

  15. 40 CFR 147.2051 - EPA-administered program-Indian lands.

    Science.gov (United States)

    2010-07-01

    ... Carolina § 147.2051 EPA-administered program—Indian lands. (a) Contents. The UIC program for all classes of... these requirements. (b) Effective date. The effective date of the UIC program for Indian lands in South Carolina is November 25, 1988. [53 FR 43090, Oct. 25, 1988, as amended at 56 FR 9419, Mar. 6, 1991] ...

  16. Ambient Radon-222 Monitoring in Amargosa Valley, Nevada

    International Nuclear Information System (INIS)

    L.H. Karr; J.J. Tappen; D. Shafer; K.J. Gray

    2008-01-01

    As part of a program to characterize and baseline selected environmental parameters in the region around the proposed repository at Yucca Mountain, Nevada, ambient radon-222 monitoring was conducted in the rural community of Amargosa Valley, the community closest to the proposed repository site. Passive integrating radon monitors and a continuous radon monitoring instrument were deployed adjacent to the Community Environmental Monitoring Program (CEMP) (http://www.cemp.dri.edu/index.html) station located in the Amargosa Valley Community Center near the library. The CEMP station provided real-time ambient gamma exposure and meteorological data used to correct the integrated radon measurements as well as verify meteorological data collected by the continuous radon monitoring instrument. Additionally, different types of environmental enclosures that housed the monitors and instrument were used to determine if particular designs influenced the ambient radon measurements

  17. Proceedings of the Radon national action plan workshop

    International Nuclear Information System (INIS)

    Chevet, Pierre-Franck; Godet, Jean-Luc; Tirmarche, Margot; Strand, Per; Mrdakovic Popic, Jelena; Dysvik, Solveig; Skjold, Anne Marit; Vallet, Benoit; Van Deventer, Emilie; Colgan, Tony; ); Mundigl, Stefan; ); Magnusson, S.; Long, Bill; McBurney, Ruth; Thompson, P.A; Pollard, David; Fenton, David; Long, Stephanie; Dehandschutter, Boris; Murith, Christophe; Skeppstroem, Kirlna; Petrova, Karla; Davidkova, Jana; Pravdova, Eva; Kiselev, Sergey; Mc Coll, Neil; Vallet, Jeremie; Rannou, Alain; Kurttio, Paivi; Martinsen, Finn; Roulet, Claude-Alain; Goyette, Joelle; Frutos, Borja; Olaya, Manuel; Linares Alemparte, Pilar; Marinko, Janez; Garcia-Talavera, Marta; Pedrazzi, Lisa; Mc Laughlin, James; Gutierrez-Villanueva, Jose-Luis; Janssens, Augustin

    2015-01-01

    Following the publication of the new European Basic Safety Standards Directive (the Council Directive 2013/59/EURATOM ), published in January 2014, Member States of the European Union have 4 years to incorporate it and to prepare or update their strategy for reducing radon concentration and the associated national radon action plan. Under a joint initiative from ASN and NRPA, 20 European countries, represented by authorities in charge of Radiation Protection, Health, Labour and Housing and Landscaping were brought together during a workshop on national radon action plans. The objective of the workshop, held in ASN's premises, was to share the views and experiences concerning national strategies for reducing radon exposure of the population and associated lung cancer risk. The radon workshop was supported by the World Health Organisation (WHO), the International Atomic Energy Agency (IAEA), the Heads of European Radiation protection Control Authorities (HERCA) and the European Commission (EC). Authorities from USA (EPA, CRCPD), Canada (CNSC) and Russia (FMBA) and the European Radon Association (ERA) also participated in the workshop. This radon workshop has offered the opportunity to compare the actions in place or in preparation in different countries aiming at reducing radon exposure in home and dwellings, in buildings with public access (i.e. schools) and in workplaces. Preventive and corrective solutions, associated with incentives and communication to increase the public awareness, as well as education and training actions for different actors concerned, have been presented and discussed. The question about the relative place of regulation in the national strategy has been considered as an important key point. This document brings together the presentations (slides) given at the workshop. The main conclusions of the workshop are presented at the end of the document

  18. Calculating CR-39 Response to Radon in Water Using Monte Carlo Simulation

    International Nuclear Information System (INIS)

    Razaie Rayeni Nejad, M. R.

    2012-01-01

    CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arrive at CR-39, the calibration factor, and the suitable depth of chemical etching of CR-39 in air and water was calculated. In this simulation, a range of data were obtained from SRIM2008 software. Calibration factor of CR-39 in water is calculated as 6.6 (kBq.d/m 3 )/(track/cm 2 ) that is corresponding with EPA standard level of Radon concentration in water (10-11 kBq/m 3 ). With replacing the skin instead of CR-39, the volume affected by Radon and progeny was determined to be 2.51 mm 3 for one m 2 of skin area. The annual dose conversion factor for Radon and progeny was calculated to be between 8.8-58.8 nSv/(Bq.h/m 3 ). Using the CR-39 for Radon measurement in water can be beneficial. The annual dose conversion factor for Radon and progeny was calculated to be between 8.8-58.8 nSv/ (Bq.h/m 3 ).

  19. Find a Radon Test Kit or Measurement and Mitigation Professional

    Science.gov (United States)

    Find a qualified radon service professional to fix or mitigate your home. If you have questions about a radon, you should contact your state radon contact and/or contact one or both of the two privately-run National Radon Proficiency Programs

  20. Indoor Radon Concentration Related to Different Radon Areas and Indoor Radon Prediction

    Science.gov (United States)

    Juhásová Šenitková, Ingrid; Šál, Jiří

    2017-12-01

    Indoor radon has been observed in the buildings at areas with different radon risk potential. Preventive measures are based on control of main potential radon sources (soil gas, building material and supplied water) to avoid building of new houses above recommended indoor radon level 200 Bq/m3. Radon risk (index) estimation of individual building site bedrock in case of new house siting and building protection according technical building code are obligatory. Remedial actions in buildings built at high radon risk areas were carried out principally by unforced ventilation and anti-radon insulation. Significant differences were found in the level of radon concentration between rooms where radon reduction techniques were designed and those where it was not designed. The mathematical model based on radon exhalation from soil has been developed to describe the physical processes determining indoor radon concentration. The model is focused on combined radon diffusion through the slab and advection through the gap from sub-slab soil. In this model, radon emanated from building materials is considered not having a significant contribution to indoor radon concentration. Dimensional analysis and Gauss-Newton nonlinear least squares parametric regression were used to simplify the problem, identify essential input variables and find parameter values. The presented verification case study is introduced for real buildings with respect to various underground construction types. Presented paper gives picture of possible mathematical approach to indoor radon concentration prediction.

  1. Indoor radon distribution of subway stations in a Korean major city

    International Nuclear Information System (INIS)

    Yoon, Seokwon; Chang, Byung-Uck; Kim, Yongjae; Byun, Jong-In; Yun, Ju-Yong

    2010-01-01

    The overall survey on indoor radon concentration was conducted at all subway stations in a major city, Daejeon in the central part of Korea. It was quarterly performed from September 2007 to August 2008. The annual arithmetic mean of indoor radon concentration of all the stations was 34.1 ± 14.7 Bq m -3 , and the range of values was from 9.4 to 98.2 Bq m -3 . The radon concentrations in groundwater (average 31.0 ± 0.8 Bq m -3 ) were not significantly high in most stations, but the concentration (177.9 ± 2.3 Bq L -1 ) of one station was over the level of 148 Bq L -1 in drinking water proposed by U.S. EPA. Based on indoor survey results, the approximate average of the annual effective dose by radon inhalation to the employees and passengers were 0.24 mSv y -1 , and 0.02 mSv y -1 , respectively. Although the effective dose based on the UNSCEAR report was potentially estimated, for more accurate assessment, the additional survey on the influence by indoor radon will be necessary.

  2. Indoor radon distribution of subway stations in a Korean major city

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seokwon [Korea Institute of Nuclear Safety, Gwahak-ro 34, Yuseong-gu, 305-338 Daejeon (Korea, Republic of); Chang, Byung-Uck, E-mail: hafadai@kins.re.k [Korea Institute of Nuclear Safety, Gwahak-ro 34, Yuseong-gu, 305-338 Daejeon (Korea, Republic of); University of Science and Technology, Gwahak-ro 113, Yuseong-gu, 305-333 Daejeon (Korea, Republic of); Kim, Yongjae [Korea Institute of Nuclear Safety, Gwahak-ro 34, Yuseong-gu, 305-338 Daejeon (Korea, Republic of); Byun, Jong-In [University of Science and Technology, Gwahak-ro 113, Yuseong-gu, 305-333 Daejeon (Korea, Republic of); Yun, Ju-Yong [Korea Institute of Nuclear Safety, Gwahak-ro 34, Yuseong-gu, 305-338 Daejeon (Korea, Republic of); University of Science and Technology, Gwahak-ro 113, Yuseong-gu, 305-333 Daejeon (Korea, Republic of)

    2010-04-15

    The overall survey on indoor radon concentration was conducted at all subway stations in a major city, Daejeon in the central part of Korea. It was quarterly performed from September 2007 to August 2008. The annual arithmetic mean of indoor radon concentration of all the stations was 34.1 +- 14.7 Bq m{sup -3}, and the range of values was from 9.4 to 98.2 Bq m{sup -3}. The radon concentrations in groundwater (average 31.0 +- 0.8 Bq m{sup -3}) were not significantly high in most stations, but the concentration (177.9 +- 2.3 Bq L{sup -1}) of one station was over the level of 148 Bq L{sup -1} in drinking water proposed by U.S. EPA. Based on indoor survey results, the approximate average of the annual effective dose by radon inhalation to the employees and passengers were 0.24 mSv y{sup -1}, and 0.02 mSv y{sup -1}, respectively. Although the effective dose based on the UNSCEAR report was potentially estimated, for more accurate assessment, the additional survey on the influence by indoor radon will be necessary.

  3. Procedure manual for the estimation of average indoor radon-daughter concentrations using the radon grab-sampling method

    International Nuclear Information System (INIS)

    George, J.L.

    1986-04-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center to provide standardization, calibration, comparability, verification of data, quality assurance, and cost-effectiveness for the measurement requirements of DOE remedial action programs. One of the remedial-action measurement needs is the estimation of average indoor radon-daughter concentration. One method for accomplishing such estimations in support of DOE remedial action programs is the radon grab-sampling method. This manual describes procedures for radon grab sampling, with the application specifically directed to the estimation of average indoor radon-daughter concentration (RDC) in highly ventilated structures. This particular application of the measurement method is for cases where RDC estimates derived from long-term integrated measurements under occupied conditions are below the standard and where the structure being evaluated is considered to be highly ventilated. The radon grab-sampling method requires that sampling be conducted under standard maximized conditions. Briefly, the procedure for radon grab sampling involves the following steps: selection of sampling and counting equipment; sample acquisition and processing, including data reduction; calibration of equipment, including provisions to correct for pressure effects when sampling at various elevations; and incorporation of quality-control and assurance measures. This manual describes each of the above steps in detail and presents an example of a step-by-step radon grab-sampling procedure using a scintillation cell

  4. LIFETIME LUNG CANCER RISKS ASSOCIATED WITH INDOOR RADON EXPOSURE BASED ON VARIOUS RADON RISK MODELS FOR CANADIAN POPULATION.

    Science.gov (United States)

    Chen, Jing

    2017-04-01

    This study calculates and compares the lifetime lung cancer risks associated with indoor radon exposure based on well-known risk models in the literature; two risk models are from joint studies among miners and the other three models were developed from pooling studies on residential radon exposure from China, Europe and North America respectively. The aim of this article is to make clear that the various models are mathematical descriptions of epidemiologically observed real risks in different environmental settings. The risk from exposure to indoor radon is real and it is normal that variations could exist among different risk models even when they were applied to the same dataset. The results show that lifetime risk estimates vary significantly between the various risk models considered here: the model based on the European residential data provides the lowest risk estimates, while models based on the European miners and Chinese residential pooling with complete dosimetry give the highest values. The lifetime risk estimates based on the EPA/BEIR-VI model lie within this range and agree reasonably well with the averages of risk estimates from the five risk models considered in this study. © Crown copyright 2016.

  5. Characterizing the occurrence, sources, and variability of radon in Pacific Northwest homes.

    Science.gov (United States)

    Turk, B H; Prill, R J; Grimsrud, D T; Moed, B A; Sextro, R G

    1990-04-01

    A compilation of data from earlier studies of 172 homes in the Pacific Northwest indicated that approximately 65 percent of the 46 homes tested in the Spokane River Valley/Rathdrum Prairie region of eastern Washington/northern Idaho had heating season indoor radon (222Rn) concentrations above the U. S. EPA guideline of 148 Bq m-3 (4 pCi L-1). A subset of 35 homes was selected for additional study. The primary source of indoor radon in the Spokane River Valley/Rathdrum Prairie was pressure-driven flow of soil gas containing moderate radon concentrations (geometric mean concentration of 16,000 Bq m-3) from the highly permeable soils (geometric mean permeability of 5 x 10(-11) m2) surrounding the house substructures. Estimated soil gas entry rates ranged from 0.4 to 39 m3h-1 and 1 percent to 21 percent of total building air infiltration. Radon from other sources, including domestic water supplies and building materials was negligible. In high radon homes, winter indoor levels averaged 13 times higher than summer concentrations, while in low radon homes winter levels averaged only 2.5 times higher. Short-term variations in indoor radon were observed to be dependent upon indoor-outdoor temperature differences, wind speed, and operation of forced-air furnace fans. Forced-air furnace operation, along with leaky return ducts and plenums, and openings between the substructure and upper floors enhanced mixing of radon-laden substructure air throughout the rest of the building.

  6. Characterizing the occurrence, sources, and variability of radon in pacific northwest homes

    International Nuclear Information System (INIS)

    Turk, B.H.; Prill, R.J.; Grimsrud, D.T.; Moed, B.A.; Sextro, R.G.

    1990-01-01

    A compilation of data from earlier studies of 172 homes in the Pacific Northwest indicated that approximately 65 percent of the 46 homes tested in the Spokane River Valley/Rathdrum Prairie region of eastern Washington/northern Idaho had heating season indoor radon ( 222 Rn) concentrations above the U.S. EPA guideline of 148 Bq m -3 (4 pCi L -1 ). A subset of 35 homes was selected for additional study. The primary source of indoor radon in the Spokane River Valley/Rathdrum Prairie was pressure-driven flow of soil gas containing moderate radon concentrations (geometric mean concentration of 16,000 Bq m -3 ) from the highly permeable soils (geometric mean permeability of 5 x 10 -11 m 2 ) surrounding the house substructures. Estimated soil gas entry rates ranged from 0.4 to 39 m 3 h -1 and 1 percent to 21 percent of total building air infiltration. Radon from other sources, including domestic water supplies and building materials was negligible. In high radon homes, winter indoor levels averaged 13 times higher than summer concentrations, while in low radon homes winter levels averaged only 2.5 times higher. Short-term variations in indoor radon were observed to be dependent upon indoor-outdoor temperature differences, wind speed, and operation of forced-air furnace fans. Forced-air furnace operations, along with leaky return ducts and plenums, and openings between the substructure and upper floors enhanced mixing of radon laden substructure air throughout the rest of the building

  7. Contribution of radon in natural gas to the dose from aiborne radon-daughters in homes

    International Nuclear Information System (INIS)

    Barton, C.J.; Moore, R.E.; Rohwer, P.S.

    1973-01-01

    Data have been obtained on the radon concentration in natural gas supplied to several metropolitan areas in the United States. The average value of 20 pCi/l was selected to estimate the contribution of this source of natural radioactivity to doses from radon-daughters received by individuals in homes. Radon-daughter concentrations in the home atmosphere were calculated by use of computer programs for an 8000 ft 3 house in which 27 ft 3 of gas per day was used for cooking in an unvented kitchen range. The total estimated dose to the bronchial epithelium included contributions from radon plus daughters in the outside ventilation air, each of which was assumed to be present at a concentration of 0.13 pCi/l, and from the radon plus daughters in the natural gas. The latter contribution averaged approximately 3 percent of the total dose. There was a 3.5 percent decrease in the estimated total dose when the air change rate increased from 0.25 to 2.0 per hour. We conclude that radon and radon-daughters entering the home with natural gas produce a negligible fraction of the total dose to the respiratory system of home occupants from airborne radon-daughters

  8. Radiological risk assessment of environmental radon

    Energy Technology Data Exchange (ETDEWEB)

    Khalid, Norafatin; Majid, Amran Ab; Yahaya, Redzuwan; Yasir, Muhammad Samudi [Nuclear Science Programme, School of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor Darul Ehsan (Malaysia)

    2013-11-27

    action level for radon gas of 148 Bq m{sup −3} proposed by EPA except monazite 0.15 kg, struverite 0.15 kg and 0.25 kg. Whereas, all building material samples have exceeded the radon concentration in concrete and building materials of 3 to 7 Bq m{sup −3} estimated by ICRP. The annual effective dose, effective dose equivalent, and radon exhalation rates in tin tailings were calculated to be in the range of 2.47 to 11.46 mSv, 5.94 to 1090.56 mSv y{sup −1}, and 0.23 to 1.18 mBq kg{sup −1} h{sup −1}. For building materials, the calculated risk assessment of the annual effective dose, effective dose equivalent, radon exhalation rates and fatal cancer risk were 0.72 to 10.00 mSv, 1.73 to 24.00 mSv y{sup −1}, 0.010 to 0.06 mBq kg{sup −1} h{sup −1} and 40 to 550 chances of persons will suffer the cancer per million (1 × 10{sup 6}), respectively.

  9. Radon determination by activated charcoal adsorption and liquid scintillation measurement

    International Nuclear Information System (INIS)

    Lopez, F.O.; Canoba, A.C.

    1998-01-01

    A passive diffusion method for the determination of radon concentration has been optimised and calibrated. The device consists of a scintillation vial containing activated charcoal, a diffusion barrier and a desiccant agent. The response to diverse atmospheric humidity and variable exposure intervals was studied. The result is a detector, which is independent of atmospheric humidity for at least (up to) 7 days of exposure. The method was compared with electret detectors (US EPA) with very satisfactory results. The advantages of this method are its simplicity, low cost, low detection limit, the total automatization of the measurement and its total independence of humidity to measure in a wide range of radon concentrations. (author) [es

  10. Indoor radon -- a strategic perspective

    International Nuclear Information System (INIS)

    Nero, A.V.

    1992-01-01

    Even the average 222 Rn concentration in US homes corresponds to an estimated individual lifetime risk of fatal lung cancer between 0.1% and 1%, depending on whether one smokes or not. Perhaps 50,000 to 100,000 homes have ten times the average or more, implying radiation doses to the occupants at or above the occupational radiation limit. But even this picture has been exaggerated by information provided the public by the EPA and the media, associating with nonsmokers risk estimated for smokers, and -- due to a faulty monitoring protocol -- giving the impression that a large fraction of homes have elevated levels. The result has been a program that focuses in fact on slightly-above-average indoor levels, while having no program for rapidly identifying and assisting those living at genuinely high levels. A sensible and effective strategy, in contrast, would (1) rely on accurate and specific public information, (2) recommend a monitoring protocol yielding the annual-average concentration in living space, the parameter of health significance, (3) constitute a national program to identify systematically and rapidly the areas of the country where the bulk of the high-radon homes occur, (4) build a sensible long-term research and action program associated with lower concentrations. Accomplishing these purposes will require a commitment to careful analysis and planning, involving an effective interaction with the scientific community, that has so far not been demonstrated

  11. Communicating the risk from radon

    International Nuclear Information System (INIS)

    Fisher, A.; McClelland, G.H.; Schulze, W.D.; Doyle, J.K.

    1991-01-01

    A prominent television station developed a special series of newscasts and public service announcements about radon. This was combined with their advertising of the availability of reduced-price radon test kits in a local supermarket chain. The large number of test kits sold was a success from a marketing perspective, but not from a public health perspective - especially because of the very small share of high readings that were mitigated. In contrast, a study of housing sales showed a much higher testing rate and corresponding mitigation when risk communication accompanied the housing transaction, rather than being directed toward the general public. This paper examined the relative effectiveness of these alternative approaches to radon risk communication, emphasizing the implications for developing and implementing radon programs

  12. A study of radon-222 concentrations in North Carolina groundwater

    International Nuclear Information System (INIS)

    Evans, J.P.

    1992-01-01

    The groundwater of 400 North Carolina homes was sampled to ascertain the distribution and extent of 222 Rn in North Carolina groundwater. Arithmetic mean (AM) and geometric mean (GM) concentrations of 1,816 pCi L -1 and 656 pCi L -1 were found for the state. These results indicate that two-thirds of 114 degree C. homes served by groundwater exceed the EPA proposed 300 pCi L -1 maximum contaminant level (MCL). Only 2% of NC homes exceeded 10,000 pCi L-1. The Eastern region had the lowest radon concentrations by far, with a GM of 2-)0 pCi L -1 . The Central region and Western region had GM's of 794 pCi L -1 and 1,032 pCi L -1 respectively. The groundwater data approached a log normal distribution. No consistent trends were noted in the relationship between indoor radon concentrations and groundwater radon concentrations. A correlation coefficient of 0.00921 revealed a very weak linear relationship

  13. Coordinated indoor radon surveys in some Arab countries

    International Nuclear Information System (INIS)

    Al-Azmi, D.; Al-Abed, T.; Alnasari, M.S.; Borham, E.E.; Chekir, Z.; Khalifa, M.S.; Shweikani, R.

    2012-01-01

    Indoor radon surveys were carried out in some of the Arab countries through a Coordination Research Program (CRP) organized by the Arab Atomic Energy Agency (AAEA). The objectives of the program aim at establishing a database on indoor radon concentration levels in the region and investigating any anomalies, where they exist. The approach adopted by the survey teams to achieve public participation in accepting the radon detectors in dwellings is presented and discussed. Most of the participants in the CRP used the passive method (CR-39 plastic detectors) for long-term radon measurements, while others used charcoal detectors and E-Perm systems for short-term measurements. The results of the surveys showed that radon concentration levels in most of the dwellings were low, whilst in some old cities and in an area close to a phosphate mine the levels were found to be relatively high. (authors)

  14. National Radon Contractor Proficiency Program. Proficiency report: Supplement

    International Nuclear Information System (INIS)

    1991-02-01

    The report, a supplement to the RCP Proficiency Report, will further assist governmental officials in providing advice to the public on the selection of proficient radon mitigation contractors. These reports list 1,123 contractors who have met the requirements of the RCP Program as of December 15, 1990. The Proficiency Report provides information on each contractor's name, RCP identification number, company name, address, phone number, and geographic service area. The report provides two additional tables, indexed by company name and by RCP identification number. The report is intended to help users quickly identify a proficient contractor if only the company name is known, or to verify which contractor is associated with a particular ID number

  15. Risk assessment of radon gas concentration for some selected offices of KNUST campus, Kumasi

    International Nuclear Information System (INIS)

    Bediako, Yaw Addo

    2013-11-01

    Radon (Rn-222) has been identified as an factor that could result in a health hazard by studies all around the world. The health risks can be minimised by preventing measures where radon is highly concentrated as in some mines or homes or offices. A study in the buildup concentration of the inert gas, will give us a better understanding of its possible pathways through soil into the air surrounding and offices where radon releases can become hazardous. Measuring the radon concentrations on campus, can help to deduce the radon flux to identify the problem areas for rehabilitation. An active method incorporating Trace level radon gas detection and continious monitoring method was used in this study to determine the radon concentration of the selected offices. Concentrations ranging from 0.010 to 0.498 pCi/I were detected, with the head of optometry and Visual Science recording the highest concentration of 0.498 pCi/I, while the head of Agricultural Engineering Department office with the least concentration of 0.010 pCi/I. Although these concentrations are generally low as compared with the EPA guidelines of an action level of 4 pCi/I, but no amount of radiation is said to be safe. (au)

  16. Radon legislation and national guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Aakerblom, G

    1999-07-01

    50-500 Bq/l for public waters and 200-1000 Bq/l for private water supplies. 4 EU member states and 11 non-EU European countries have reference levels for the concentration of radioactive elements in building materials. 8 European countries have guidelines regarding radon at city planning and 13 have mapped the radon risk in their countries. It is essential to the work against radon and to future reduction of radon concentrations in dwellings and workplaces that the national states issue recommendations, regulations, directives or laws on radon limits and building practices. In order to have a significant effect on the radon situation, the questionnaire responses show that radon reference levels and regulations must be enforced or very little progress is achieved. Extensive measurement and research programs have been carried out in many in countries. Heretofore, only those countries with enforced regulations have had successful programs, resulting in remedial actions in more than 10,000 buildings. The only exception is USA, which concentrated on extensive information media campaigns on radon and the training of large numbers of contractors to perform measurements and remedial measures.

  17. Radon legislation and national guidelines

    International Nuclear Information System (INIS)

    Aakerblom, G.

    1999-07-01

    -500 Bq/l for public waters and 200-1000 Bq/l for private water supplies. 4 EU member states and 11 non-EU European countries have reference levels for the concentration of radioactive elements in building materials. 8 European countries have guidelines regarding radon at city planning and 13 have mapped the radon risk in their countries. It is essential to the work against radon and to future reduction of radon concentrations in dwellings and workplaces that the national states issue recommendations, regulations, directives or laws on radon limits and building practices. In order to have a significant effect on the radon situation, the questionnaire responses show that radon reference levels and regulations must be enforced or very little progress is achieved. Extensive measurement and research programs have been carried out in many in countries. Heretofore, only those countries with enforced regulations have had successful programs, resulting in remedial actions in more than 10,000 buildings. The only exception is USA, which concentrated on extensive information media campaigns on radon and the training of large numbers of contractors to perform measurements and remedial measures

  18. Plastic-bag radon gas monitor and survey results

    International Nuclear Information System (INIS)

    Torri, G.

    1990-01-01

    The Plastic-bag radon monitor used in the Italian National Survey is described. The choice of this radon gas sampler has been determined by the peculiarity of the italian environmental monitoring program, which is carried out by several different regional laboratories. Results obtained in the past using this radon monitoring device are also reported. (author). 8 refs, 7 figs

  19. Radon survey related to construction materials and soils in Zacatecas, Mexico using LR-115

    International Nuclear Information System (INIS)

    Mireles, F.; Garcia, M.L.; Quirino, L.L.; Davila, J.I.; Pinedo, J.L.; Rios, C.; Montero, M.E.; Colmenero, L.; Villalba, L.

    2007-01-01

    Indoor radon gas ( 222 Rn), present in the air inside buildings, is one of the most important sources of radiation exposure to the population. This gas originates in the 238 U radioactive decay chain, which is contained in rock and solid soil particles. Radon accumulation in confined spaces, inside buildings, depends on several factors such as the type of soils, type of constructions, building materials, and ventilation. The aim of this work is to present indoor and outdoor radon concentrations for 202 dwellings and indoor concentrations for 148 public clinics; and the radon concentrations relate to the type of predominant soils, the construction years; and building materials used in the ceilings, walls and floors, for cities and towns of the 57 municipalities in the State of Zacatecas, Mexico. The 222 Rn concentrations were measured with a passive-type radon monitor, with LR-115 as detector material; and the radon survey was made during four stages of three months each throughout Zacatecas from 2001 to 2002. The indoor and outdoor radon concentration averages in dwellings were 55.6±4.9Bqm -3 and 46.5±5.3Bqm -3 , respectively. The indoor radon concentration average in public clinics was 57.8±5.4Bqm -3 . These values were lower than the US EPA action limit of 148Bqm -3

  20. Radon in Estonian dwellings - Results from a National Radon Survey

    Energy Technology Data Exchange (ETDEWEB)

    Pahapill, Lia; Rulkov, Anne; Rajamaee, Raivo [Estonian Radiation Protection Centre (Kiirguskeskus), Tallinn (Spain); Aakerblom, Gustav [Swedish Radiation Protection Authority, Stockholm (Sweden)

    2003-10-01

    A countrywide survey of radon concentrations in Estonian dwellings was carried out during the period 1998-2001. The survey formed a part of the cooperation program on radiation protection between the Estonian Radiation Protection (Kiirguskeskus) Centre and the Swedish Radiation Protection Authority (SSI). The survey included measurements in a number of dwellings representative for Estonia in detached houses and multifamily buildings (only dwellings on the bottom floor were included in the survey). Altogether, radon concentrations were measured in 515 dwellings, a number large enough to be statistically significant. All measurements were made with alphatrack film detectors of the same type that SSI uses in Sweden. The measurements were made during a 2-3 month period during the winter half-year. Two detectors were used in each dwelling. In Estonia there are 0.17 million dwellings in detached houses and 0.45 million in multi apartment buildings. Of the 1.26 million inhabitants in Estonia. 0.36 million live in detached houses and 0.90 million in multi apartment buildings. Most of the latter were built during the Soviet occupation. Of the dwellings in multifamily buildings 30 % are assumed to be situated on the first floor. The mean radon concentration in dwellings in detached hoses, according to the survey results, is 103 Bq/m{sup 3}, in dwellings on the bottom floor in multi apartment buildings it is 78 Bq/m{sup 3}. In 1% of the dwellings the radon concentration exceeded 400 Bq/m{sup 3}. The highest radon concentration found in the study was 1040 Bq/m{sup 3}. Based on the assumption that the average radon concentration in the dwellings in multi-apartment buildings that are not situated on the bottom floor is 30 Bq/m{sup 3}, and that these dwellings constitute 70% of all dwellings in multi apartment buildings, the mean radon concentration in dwellings in multi apartment buildings is calculated to be 44 Bq/m{sup 3}. The mean value for all Estonia dwellings is calculated

  1. Radon in Estonian dwellings - Results from a National Radon Survey

    International Nuclear Information System (INIS)

    Pahapill, Lia; Rulkov, Anne; Rajamaee, Raivo; Aakerblom, Gustav

    2003-10-01

    A countrywide survey of radon concentrations in Estonian dwellings was carried out during the period 1998-2001. The survey formed a part of the cooperation program on radiation protection between the Estonian Radiation Protection (Kiirguskeskus) Centre and the Swedish Radiation Protection Authority (SSI). The survey included measurements in a number of dwellings representative for Estonia in detached houses and multifamily buildings (only dwellings on the bottom floor were included in the survey). Altogether, radon concentrations were measured in 515 dwellings, a number large enough to be statistically significant. All measurements were made with alphatrack film detectors of the same type that SSI uses in Sweden. The measurements were made during a 2-3 month period during the winter half-year. Two detectors were used in each dwelling. In Estonia there are 0.17 million dwellings in detached houses and 0.45 million in multi apartment buildings. Of the 1.26 million inhabitants in Estonia. 0.36 million live in detached houses and 0.90 million in multi apartment buildings. Most of the latter were built during the Soviet occupation. Of the dwellings in multifamily buildings 30 % are assumed to be situated on the first floor. The mean radon concentration in dwellings in detached hoses, according to the survey results, is 103 Bq/m 3 , in dwellings on the bottom floor in multi apartment buildings it is 78 Bq/m 3 . In 1% of the dwellings the radon concentration exceeded 400 Bq/m 3 . The highest radon concentration found in the study was 1040 Bq/m 3 . Based on the assumption that the average radon concentration in the dwellings in multi-apartment buildings that are not situated on the bottom floor is 30 Bq/m 3 , and that these dwellings constitute 70% of all dwellings in multi apartment buildings, the mean radon concentration in dwellings in multi apartment buildings is calculated to be 44 Bq/m 3 . The mean value for all Estonia dwellings is calculated to be 60 Bq/m 3 . Using

  2. Control of indoor radon and radon progeny concentrations

    International Nuclear Information System (INIS)

    Sextro, R.G.

    1985-05-01

    There are three general categories of techniques for the control of radon and radon progeny concentrations in indoor air - restriction of radon entry, reduction of indoor radon concentrations by ventilation or air cleaning, and removal of airborne radon progeny. The predominant radon entry process in most residences appears to be pressure driven flow of soil gas through cracks or other openings in the basement, slab, or subfloor. Sealing these openings or ventilation of the subslab or subfloor space are methods of reducing radon entry rates. Indoor radon concentrations may be reduced by increased ventilation. The use of charcoal filters for removal of radon gas in the indoor air by adsorption has also been proposed. Concentrations of radon progeny, which are responsible for most of the health risks associated with radon exposures, can be controlled by use of electrostatic or mechanical filtration. Air circulation can also reduce radon progeny concentrations in certain cases. This paper reviews the application and limitations of each of these control measures and discusses recent experimental results

  3. Uranium mill tailings and radon

    International Nuclear Information System (INIS)

    Hanchey, L.A.

    1981-01-01

    The major health hazard from uranium mill tailings is presumed to be respiratory cancer resulting from the inhalation of radon daughter products. A review of studies on inhalation of radon and its daughters indicates that the hazard from the tailings is extremely small. If the assumptions used in the studies are correct, one or two people per year in the US may develop cancer as a result of radon exhaled from all the Uranium Mill Tailings Remedial Action Program sites. The remedial action should reduce the hazard from the tailings by a factor of about 100

  4. Uranium mill tailings and radon

    Energy Technology Data Exchange (ETDEWEB)

    Hanchey, L A

    1981-04-01

    The major health hazard from uranium mill tailings is presumed to be respiratory cancer resulting from the inhalation of radon daughter products. A review of studies on inhalation of radon and its daughters indicates that the hazard from the tailings is extremely small. If the assumptions used in the studies are correct, one or two people per year in the United States may develop cancer as a result of radon exhaled from all the Uranium Mill Tailings Remedial Action program sites. The remedial action should reduce the hazard from the tailings by a factor of about 100.

  5. Uranium mill tailings and radon

    Energy Technology Data Exchange (ETDEWEB)

    Hanchey, L A

    1981-01-01

    The major health hazard from uranium mill tailings is presumed to be respiratory cancer resulting from the inhalation of radon daughter products. A review of studies on inhalation of radon and its daughters indicates that the hazard from the tailings is extremely small. If the assumptions used in the studies are correct, one or two people per year in the US may develop cancer as a result of radon exhaled from all the Uranium Mill Tailings Remedial Action Program sites. The remedial action should reduce the hazard from the tailings by a factor of about 100.

  6. Analysis of infiltration through a clay radon barrier at an UMTRA disposal cell

    International Nuclear Information System (INIS)

    1991-01-01

    An infiltration study was initiated in January 1988 to assess the percent saturation in, and infiltration through, clay radon barriers of typical Uranium Mill Tailings Remedial Action (UMTRA) Project disposal cells. Predicting infiltration through the radon barrier is necessary to evaluate whether the disposal cell will comply with the proposed US Environmental Protection Agency (EPA) groundwater protection standards (40 CFR 192). The groundwater standards require demonstrating that tailings seepage will not cause background concentrations or maximum concentration limits (MCLs) to be exceeded at the downgradient edge of the disposal facility (the point of compliance, or POC). This demonstration generally consists of incorporating the predicted seepage flux and the concentration of the specific hazardous constituents into a contaminant transport model, and predicting the resultant concentrations at the POC. The infiltration study consisted of a field investigation to evaluate moisture conditions in the radon barrier of the completed Shiprock, New Mexico, UMTRA Project disposal cell and previously completed UMTRA Project disposal cells at Clive, Utah, and Burrell, Pennsylvania. Coring was conducted to measure percent saturation profiles in the radon barriers at these disposal cells. In addition, a detailed investigation of the Shiprock radon barrier was conducted to establish the effects of meteorological stresses on moisture conditions in the filter layer and radon barrier. The Shiprock infiltration study was also intended to characterize hydraulic gradients and operational unsaturated hydraulic conductivities in the radon barrier

  7. Quality assurance for environmental radon measurements by LR115 nuclear track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Gomaa, M A [National Network of Radiation Physics, Atomic Energy Authority, Cairo (Egypt); Hafez, A F [Physics Department, Faculty of Science, Alexandria Univercity, Alexandria (Egypt); Hussein, A S [Radiation Protection Department, Nuclear Power Plants Authority, Cairo (Egypt)

    2007-06-15

    Passive radon dosimeters based on LR115 nuclear track detectors are very attractive for assessment of radon exposure. For developing countries wishing to undertake national radon survey the most appropriate techniques are those making use of LR115 detectors. These detectors are small, cheap, simple, and non-hazardous and provide an entirely adequate tool for large scale use in assessing levels of radon over several months because of the short - term fluctuations in radon concentrations. In this paper, the principles and philosophy in order to improve the quality and reliability of radon exposure under a quality assurance (QA) program are presented . Also examples of how a QA program of radon measurements by LR115 detectors using the can-techniques are well defined and applied.

  8. Quality assurance for environmental radon measurements by LR115 nuclear track detectors

    International Nuclear Information System (INIS)

    Gomaa, M.A.; Hafez, A.F.; Hussein, A.S.

    2007-01-01

    Passive radon dosimeters based on LR115 nuclear track detectors are very attractive for assessment of radon exposure. For developing countries wishing to undertake national radon survey the most appropriate techniques are those making use of LR115 detectors. These detectors are small, cheap, simple, and non-hazardous and provide an entirely adequate tool for large scale use in assessing levels of radon over several months because of the short - term fluctuations in radon concentrations. In this paper, the principles and philosophy in order to improve the quality and reliability of radon exposure under a quality assurance (QA) program are presented . Also examples of how a QA program of radon measurements by LR115 detectors using the can-techniques are well defined and applied

  9. Radon 222 in drinking water resources of Iran: A systematic review, meta-analysis and probabilistic risk assessment (Monte Carlo simulation).

    Science.gov (United States)

    Keramati, Hassan; Ghorbani, Raheb; Fakhri, Yadolah; Mousavi Khaneghah, Amin; Conti, Gea Oliveri; Ferrante, Margherita; Ghaderpoori, Mansour; Taghavi, Mahmoud; Baninameh, Zahra; Bay, Abotaleb; Golaki, Mohammad; Moradi, Bigard

    2018-03-30

    The current study was performed to review the conducted studies regarding the concentration of radon 222 in the tap drinking water; furthermore, by estimation of ingestion and inhalation effective dose, the health risk assessment in the adults and children using MCS technique was assessed. All related studies published among January 1990 to October 2016; were screened in the available databases such as Web of Science, PubMed, Science Direct, Scopus, SID, and Irandoc. The total effective dose was estimated by calculating E ing (Effective dose of ingestion) and E inh (Effective dose of inhalation) by Monte Carlo simulation (MCS) method. The range of ND ─ 40.9 Bq/L for radon 222 in water resources was proposed after evaluation of data collected from 13 studies with 1079 samples. The overall concentration of radon 222 in drinking water in Iran was 3.98: 95%CI (3.79 ─ 4.17 Bq/L). Also, the effective ingestion dose of radon 222 in adults age groups was 1.35 times higher than children. The rank order of drinking water resources based on the concentration of radon 222 was Spring > Spring and Well > Well > Spring and Qanat > Tap water. The overall concentration of radon 222 in drinking water in Iran was lower than WHO and EPA standard limits. Also, the rank order regarding area studied based on the concentration of radon 222 was Gillan > Mashhad > Mazandaran > Kerman > Yazd > Tehran > Kermanshah > Golestan > Hormozgan. The effective ingestion dose of radon 222 to consumers in the Gillan, Mashhad, Mazandaran, and Kerman were higher than WHO guidance (0.1 mSv/y). Also except consumers in the Hormozgan, inhalation effective dose radon 222, in the other investigated areas were higher than WHO guidance (0.1 mSv/y). Therefore, it is recommended to conduct the required programs regarding control and elimination of radon 222 concentration in Iranian drinking water supply. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Radon: a bibliography

    Energy Technology Data Exchange (ETDEWEB)

    Lepman, S.R.; Boegel, M.L.; Hollowell, C.D.

    1981-01-01

    The Lawrence Berkeley Laboratory, with the support of the Department of Energy, has developed a computerized database to manage research information in the area of building ventilation and indoor air quality. This literature survey contains references pertaining to the physical properties of radon and its daughters, instrumentation for their measurement, health effects, surveys and measurements, and regulatory information. The references in the bibliography are sequenced in alphabetical order and abstracts are included when supplied by the author. The objective of this report is to disseminate the bibliographic references compiled at the laboratory relating to radon research portion of the program. Interested database users are encouraged to contact the laboratory to receive instructions for direct database acess. A flyer describing the database is supplied at the end of the bibliography and a brief overview of the Radon Research porgram is given.

  11. Radon: a bibliography

    International Nuclear Information System (INIS)

    Lepman, S.R.; Boegel, M.L.; Hollowell, C.D.

    1981-01-01

    The Lawrence Berkeley Laboratory, with the support of the Department of Energy, has developed a computerized database to manage research information in the area of building ventilation and indoor air quality. This literature survey contains references pertaining to the physical properties of radon and its daughters, instrumentation for their measurement, health effects, surveys and measurements, and regulatory information. The references in the bibliography are sequenced in alphabetical order and abstracts are included when supplied by the author. The objective of this report is to disseminate the bibliographic references compiled at the laboratory relating to radon research portion of the program. Interested database users are encouraged to contact the laboratory to receive instructions for direct database acess. A flyer describing the database is supplied at the end of the bibliography and a brief overview of the Radon Research porgram is given

  12. Radon/radium detection increases uranium drilling effectiveness

    International Nuclear Information System (INIS)

    Morse, R.H.; Cook, L.M.

    1979-01-01

    The use of portable radon detectors has become routine in reconnaissance uranium surveys where water and sediment samples are analyzed in field labs for radon and radium, and in detailed work where drill hole locations are pinpointed by field determinations of radon in soil gas from shallow holes. During the drilling program itself, however, very few operators are taking advantage of radon and radium analyses to decide whether a barren drill hole was a near miss or whether the immediate area can be written off. The technique, which is outlined here, is effective both above and below the water table

  13. Radon

    Energy Technology Data Exchange (ETDEWEB)

    Weigel, F [Muenchen Univ. (Germany, F.R.). Inst. fuer Anorganische Chemie

    1978-09-01

    The noble gas radon, formerly called emanation, was discovered a few years after radium. /sup 222/Rn, the longest-lived isotope, has a half-life of 3,82 days. This half life is so short that the experimental techniques available at present (1978) are not sufficient for a characterization of defined radon compounds, even though there are definite indications for the existence of such compounds, and one may expect such radon compounds to be even more stable than the numerous known xenon compounds. - The radon isotopes /sup 219/Rn (Actinon), /sup 220/Rn (Thoron), and /sup 222/Rn (Radon) occur in nature despite their rather short half-lives, because they are continously generated from their mothers /sup 223/Ra, /sup 224/Ra, and /sup 226/Ra, which are in secular equilibrium with long-lived isotopes /sup 235/U, /sup 238/U, and /sup 232/Th, and are in turn continously formed from these long-lived isotopes. Since the radon isotopes are gases, they enter the atmosphere and are carried for long distances with air currents. - Because radon is so short-lived, its practical applications are rather limited. For medical applications, small sealed glass tubes filled with radon are used as radiation sources after the radon has decayed, because the whole series of Po-, Bi-, and Pb-isotopes of the radium decay chain are formed, whose penetrating radiation is useful for therapy. When solids are spiked with Ra isotopes, radon is evolved at a constant rate. On heating such solids, phase transitions show up by sudden increased radon evolution (Hahn's emanation method). - On the basis of nuclear theoretical calculations, there is hardly a chance for the discovery of a long-lived radon species. Therefore, major progress in radon chemistry is hardly to be expected in the near future.

  14. Operating instructions for LBL radon measurement facilities

    International Nuclear Information System (INIS)

    Ingersoll, J.G.

    1980-06-01

    This manual is intended for users of the radon-measuring facilities of the Radon Project of the Building Ventilation and Indoor Air Quality Program at Lawrence Berkeley Laboratory. The manual comprises three parts. Part 1 sets out the steps involved in collecting, transferring, and counting radon. Part 2 describes the calibration of the transfer system and of the Lucas cells in the counting system. Part 3 outlines the maintenance procedures for the facility

  15. Radon mitigation in schools utilising heating, ventilating and air conditioning systems

    International Nuclear Information System (INIS)

    Fisher, G.; Ligman, B.; Brennan, T.; Shaughnessy, R.; Turk, B.H.; Snead, B.

    1994-01-01

    As part of a continuing radon in schools technology development effort, EPA's School Evaluation Team has performed radon mitigation in schools by the method of ventilation/pressurisation control technology. Ventilation rates were increased, at a minimum, to meet the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) standard, Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1989). This paper presents the results and the preliminary evaluations which led to the team's decision to implement this technology. Factors considered include energy penalties, comfort, indoor air quality (IAQ), building shell tightness, and equipment costs. Cost benefit of heat recovery ventilation was also considered. Earlier results of the SEP team's efforts have indicated a severe ventilation problem within the schools of the United States. Two case studies are presented where HVAC technology was implemented for controlling radon concentrations. One involved the installation of a heat recovery ventilator to depressurise a crawl space and provide ventilation to the classrooms which previously had no mechanical ventilation. The other involved the restoration of a variable air volume system in a two-storey building. The HVAC system's controls were restored and modified to provide a constant building pressure differential to control the entry of radon. Pre-mitigation and post-mitigation indoor air pollutant measurements were taken, including radon, carbon dioxide (CO 2 ), particulates, and bio-aerosols. Long-term monitoring of radon, CO 2 , building pressure differentials, and indoor/outdoor temperature and relative humidity is presented. (author)

  16. Radon gas as a tracer for volcanic processes

    International Nuclear Information System (INIS)

    Thomas, D.M.

    1990-01-01

    Radon emissions from volcanic systems have been under investigation for several decades. Soil gas and groundwater radon activities have been used to map faults and to characterize geothermal systems, and measurements of atmospheric radon and radon daughter concentrations have been used to estimate the volume of magma chambers feeding active eruptions. Several studies have also shown that temporal variations in radon concentration have been associated with the onset of volcanic eruptions or changes in the rates or character of an eruption. Some of these studies have been able to clearly define the cause of the radon anomalies but others have proposed models of radon emission and transport that are not well supported by the known physical and chemical processes that occur in a volcanic system. In order to better characterize the processes that control radon activities in volcanic systems, it is recommended that future radon monitoring programs attempt to maintain continuous recording of radon activities; individual radon measurements should be made over the shortest time intervals possible that are consistent with acceptable counting statistics and geophysical, meteorological, and hydrological parameters should be measured in order to better define the physical processes that affect radon activities in volcanic systems. (author). 63 refs

  17. Realisation of a calibration chamber for radon in the air and establishment of a system for measuring radon in water

    International Nuclear Information System (INIS)

    Sassi, Nedra

    2011-01-01

    Radon is a radioactive gas that is naturally produced from the decay of radium. The main source of radon found in the earth's crust caused by the presence of a series of uranium (222 isotope of radon) and a series of thorium (220 isotope of radon) therein. We have optimized a new radon calibration chamber by developing an electronic system controlled by a PIC 16F877 microcontroller type to manage the various functions of the room. Several electronic circuits were developed to manage multiple functions such as pressure, temperature and controls motors and solenoids. This system can also be interfaced with a computer through programs such as LabView or Matlab.

  18. Social marketing and the reduction of indoor radon

    International Nuclear Information System (INIS)

    Bierma, T.J.; Swartzman, D.

    1990-01-01

    Indoor radon monitoring and mitigation has apparently been conducted by only a small percentage of private homeowners despite extensive media coverage of the radon issue and public information programs at the federal, state, and local levels. Whether public education programs should be informative or persuasive is an ethical decision. Arguments on each side of the issue are presented. A framework for the development of a persuasive campaign is then presented, suing the concepts of social marketing and the limited empirical evidence available on radon-related behavior. In this paper a four-step process is proposed: identify problem dimensions using focus groups and other methods, confirm dimension for market segmentation using probability samples and factor analysis, implement program and evaluate and revise

  19. Personal radon daughter dosimetry

    International Nuclear Information System (INIS)

    Stocker, H.

    1979-12-01

    The conventional means of radon daughter exposure estimatikn for uranium miners in Canada is by grab sampling and time weighting. Personal dosimetry is a possible alternative method with its own advantages and limitations. The author poses basic questions with regard to two methods of radon daughter detection, thermoluminescent chips and track-etch film. An historical review of previous and current research and development programs in Canada and in other countries is presented, as are brief results and conclusions of each dosimeter evaluation

  20. Air Quality Flags Program, U.S., 2017, EPA/OAR/OAQPS/OID

    Data.gov (United States)

    U.S. Environmental Protection Agency — This map service contains participants in EPA's Air Quality Flags Program. The map service also includes the current day's AQI forecast for each participant in the...

  1. Retrofit and preoccupancy radon mitigation program for homes

    International Nuclear Information System (INIS)

    Ibach, M.T.; Gallagher, J.H. Jr.

    1987-01-01

    A requirement was levied on a Maryland builder by the FHA to demonstrate acceptable radon levels in his homes before they would be approved for loans. This paper describes the use of products shown by appropriate tests to be effective radon barriers to meet this requirement. The sheet goods can be used in exterior and interior applications on foundation walls. The other is applied to the interior floors and/or walls of the basement area. Product installation procedures are straightforward and relatively simple. Problems encountered were routine and concerned primarily the complete sealing of floor and wall penetrations, window openings, sealing the top of the wall under the sill plate, and the location and mounting of permanent fixtures on walls and floors. Also discussed are methods of repairing ruptures of the seal, warranties to protect the homeowner, support systems and costs. Conclusions are that effective reductions in radon levels can be achieved by the application of sealants during the construction of new homes or as a retrofit to existing structures

  2. Radon removal using point-of-entry water-treatment techniques. Final report, October 1988-June 1990

    International Nuclear Information System (INIS)

    Kinner, N.E.; Malley, J.P.; Clement, J.A.

    1990-10-01

    The purpose of the EPA Cooperative Agreement was to evaluate the performance of POE granular activated carbon (GAC), and diffused bubble and bubble place aeration systems treating a ground water supply containing radon (35,620 + or - 6,717 pCi/L). The pattern of loading to the units was designed to simulate daily demand in a household. Each of the systems was evaluated with respect to three primary factors: radon removal efficiency, potential problems, and economics. The radon removal efficiencies of the POE GAC units gradually deteriorated over time from 99.7% to 79% for the GAC without pretreatment and 99.7% to 85% for the units preceded by ion exchange. The bubble plate and diffused bubble POE units were very efficient (99%) at removing radon from the water. The resilience is primarly due to the high air to water ratios supplied by the aeration blowers. One major problem associated with the aeration techniques is iron oxidation/precipitation

  3. Indoor radon and decay products: Concentrations, causes, and control strategies

    Energy Technology Data Exchange (ETDEWEB)

    Nero, A.V.; Gadgil, A.J.; Nazaroff, W.W.; Revzan, K.L.

    1990-11-01

    This report is another in the on going technical report series that addresses various aspects of the DOE Radon Research Program. It provides an overview of what is known about the behavior of radon and its decay products in the indoor environment and examines the manner in which several important classes of factors -- structural, geological, and meteorological -- affect indoor radon concentrations. Information on US indoor radon concentrations, currently available monitoring methods and novel radon control strategies are also explored. 238 refs., 22 figs., 9 tabs.

  4. Radon and aldehyde concentrations in the indoor environment. Final report

    International Nuclear Information System (INIS)

    Moschandreas, D.J.; Rector, H.E.

    1981-04-01

    Findings regarding indoor air contaminants in the energy-efficient residence (EER) in Mt. Airy, Maryland are reported. The objectives of the study were to collect and analyze relevant air quality samples (specifically radon and aldehydes), characterize the indoor air quality with respect to radon and aldehydes, and develop relationships between air infiltration rates and contaminant levels. One-fifth of the measured formaldehyde concentrations were in the range that may cause health concerns. Although indoor temperature and relative humidity affect indoor HCHO concentration, the elevated formaldehyde concentrations were measured under very low air infiltration rates. The data show that ventilation of the indoor air space is somewhat effective in reducing high HCHO concentrations. The operation of the heat exchanger led to an increase of the air infiltration rate which in turn resulted in substantial reduction of formaldehyde concentrations. A considerable number of the collected samples of indoor air displayed radon concentrations at levels higher than 1.0 to 4.0 nCim -3 (assuming an equilibrium factor of 0.5, these radon levels would correspond to working levels above the health guidelines suggested by the US EPA for homes in Florida built on land reclaimed from phosphate mining). As in the case of indoor formaldehyde concentrations, elevated indoor concentrations are substantially reduced when the infiltration rate is increased. The data base shows that the use of the air to air heat exchanger leads to reduction of indoor radon concentration by increasing the residential ventilation rate

  5. Radon

    Science.gov (United States)

    ... radon-resistant features. These features include gravel and plastic sheeting below the foundation, along with proper sealing ... lower the radon level. Detailed information about radon reduction in your home or building can be found ...

  6. Radon in service and industrial premises (rooms) of Tashkent

    International Nuclear Information System (INIS)

    Mirahmedova, N.M.; Akimov, V.A.; Mullagalieva, F.G.

    2004-01-01

    Full text: The radon map of the Tashkent is received in some approach on the basis of 800 surveyed inhabited and industrial premises, are designed average for one year radiating doze come on the average city dweller. Is paid attention to huge medical-biological danger natural and technogenesis of radon emanations, the question on acceptance of the special state program 'Radon' is put

  7. The radon

    International Nuclear Information System (INIS)

    1998-01-01

    This booklet is intended to answer briefly the most important questions about the nature and sources of radon, its pathways from environment to organism, as well as the ways to minimize its concentration in the habitat's atmosphere. The radon is a naturally appearing radioactive gas, produced through the decay of uranium and radium present in the terrestrial crust. It can be found everywhere on the planet's surface and it is emitted particularly from the granite and volcanic underground rocks as well as from certain construction materials. It is one of the agents producing pulmonary cancer, although not so dangerous as the tobacco is. The following items are elaborated in this booklet: - the place of radon in the average exposure to ionizing radiations of the French population; - the risk; - the radon in the environment (the meteorological conditions, the nature of the rocks); - radon in dwellings (radon measurements in the French dwellings, the entrance pathways of radon, the dependence of radon concentration on the profession and way of life of the inhabitants); - radon measurements; - how to reduce the radon concentration in dwellings

  8. Draft of „National Radon Programme” 2013-2017

    International Nuclear Information System (INIS)

    Ivanova, K.; Badulin, V.; Georgieva, R.

    2013-01-01

    The World Health Organization defines radon as the second most important causal factor for lung cancer after smoking and the number one factor for people who have never smoked. The draft of the new European Directive takes accounts the latest ICRP Recommendations for reducing radon exposure in buildings. The Directive requires Member States to bring into force the laws, regulations and administrative provisions. The main goal of „National Radon Programme” is establishment and implementation of long-term policy to reduce and prevent risks of public health resulting from exposure to high concentrations of indoor radon in buildings. To achieve this are required: – to establish an appropriate system; – to carry out national survey and mapping of areas with radon background; – to establish radon prevention strategies in newly constructed buildings and radon mitigation strategies in existing buildings; – to improve public awareness; – to lay down a system for protection against radon in workplaces. The implementation of the program will contribute to reducing the public exposure due to indoors due to radon. Along with the reduction of smoking, it will directly and indirectly improve the prevention of lung cancer risks. (author)

  9. Development of a portable radon detection system

    International Nuclear Information System (INIS)

    Allen, J.W.

    1976-09-01

    The presence of radon-222 in soil gas and ground water can indicate the existence of nearby uranium deposits even when heavy overburdens completely absorb the associated gamma radiation. Techniques to detect and measure radon have evolved during the past several years to the point where radon prospecting is routinely employed in a number of countries. A program to develop and field test a prototype system for measuring radon from soil gas and water is described. A prototype system employing a flow through scintillation detector was designed and constructed, utilizing standard commercial components, to provide a fieldworthy unit for testing the system concepts. Laboratory and preliminary field tests of this unit indicate that it can detect anomalous radon levels of less than 10 picoCuries per liter (pCi/l) in soil gas and ground water

  10. Radon dynamics in underwater thermal radon therapy

    International Nuclear Information System (INIS)

    Lettner, H.; Hofmann, W.; Winkler, R.; Rolle, R.; Foisner, W.

    1998-01-01

    At a facility for underwater thermal radon therapy in Bad Hofgastein, experiments were carried out with the aim of establishing radon in the air exhaled by the treated patients and of radon decay products on the skin of the patients. The time course of radon concentration in the exhaled air shows a maximum a few minutes after entering the bath, then the Rn concentration remains constant over the remaining time spent in the bath. Taking into account several simplifying assumptions, the average dose to the epidermis from radon daughters is about 50 μGy. (A.K.)

  11. Radon in buildings: instrumentation of an experimental house

    International Nuclear Information System (INIS)

    Ameon, R.; Diez, O.; Dupuis, M.; Merle-Szeremeta, A.

    2004-01-01

    IRSN decided to develop a code called RADON 2 for conducting simple and methodical studies of indoor radon concentrations. Since a validity check must be performed of the phenomenological model on which the code is based, an experimental program was initiated in 2002, within which a house in Brittany, located on a well-characterized uranium-bearing geological formation, was fitted with special instruments. After characterizing the soil underlying the house, the instrumentation implemented on site continuously monitors a number of parameters to characterize: the radon source term in the building (exhalation rate of 222 Rn at the ground/building interface and at soil surface, radon concentration in the soil and in outdoor air); radon penetration by advection (differential pressure in the house basement); the driving mechanisms for natural ventilation in the house (weather conditions, indoor temperature and relative humidity); radon distribution throughout the house by air flow and radon diffusion (indoor radon concentration at each floor of the house). Using the experimental data acquired over the past two years, the phenomena governing radon penetration inside the house (wind and stack effect) and radon extraction (fresh air supply rate) have been characterized to lay down the bases for validating the newly developed code

  12. Radon measurements in 130 schools

    International Nuclear Information System (INIS)

    Peake, R.T.; Schmidt, A.; MacWaters, J.T.; Chmelynski, H.

    1990-01-01

    During the winter of 1989, Rn screening measurements were made in 130 schools distributed across the United States. The primary purpose of the paper is to identify schools suitable for a year-long follow-up study, the results of which will be used to update EPA's guidance for Rn testing in schools. The 130 schools were selected nonrandomly using school characteristics and accessibility in areas where there were known or suspected Rn problems in homes. Levels found in this screening study may indicate the potential for Rn problems in US schools. Over half of the 130 schools tested had at least one radon measurement ≥4 pCi/L, and nearly 20% of the 3028 rooms measured ≥4 pCi/L. The number of rooms ≥4 pCi/L is often three rooms or less. However, schools with more than five rooms ≥4 pCi/L are common in some areas. The data include schools that could be typical of much of the US school population as well as schools which exhibit extreme radon problems, such as those tested in Nashville, TN and Spokane, WA

  13. Radon in Schools

    Science.gov (United States)

    ... Search Search Radon Contact Us Share Radon in Schools Related Information Managing Radon in Schools Radon Measurement ... Radon Could Be a Serious Threat to Your School Chances are you've already heard of radon - ...

  14. Radon-technical design methods based on radon classification of the soil

    International Nuclear Information System (INIS)

    Kettunen, A.V.

    1993-01-01

    Radon-technical classification of the foundation soil divides the foundation soil into four classes: negligible, normal, high and very high. Separate radon-technical designing methods and radon-technical solutions have been developed for each class. On regions of negligible class, no specific radon-technical designing methods are needed. On regions of normal radon class, there is no need for actual radon-technical designing based on calculations, whereas existing radon-technical solutions can be used. On regions of high and very high radon class, a separate radon-technical designing should be performed in each case, where radon-technical solutions are designed so that expected value for indoor radon content is lower than the maximum allowable radon content. (orig.). (3 refs., 2 figs., 2 tabs.)

  15. Radon in houses due to radon in potable water

    International Nuclear Information System (INIS)

    Hess, C.T.; Korsah, J.K.; Einloth, C.J.

    1987-01-01

    Radon concentration in the air of 10 houses has been measured as a function of water use and meterological parameters such as barometric pressure, wind velocity and direction, indoor and outdoor temperature, and rainfall. Results of calibrations and data collected in winter, spring, fall, and summer are given for selected houses. Average values of radon concentration in air are from 0.80 to 77 rhoCi/1. Water use average ranges from 70 to 240 gal/day. Average potential alpha energy concentrations in these houses range from 0.02 to 1.6 working levels. The radon level due to water use ranges from 0 to 36% of the house radon from soil and water combined. The radon level change due to use of a filter on the water supply shows a 60% reduction in radon in the house. Conclusions are that water radon can be a major fraction of the radon in houses. The ratio of airborne radon concentration due to water use to the radon concentration in water is 4.5 x 10/sup -5/ - 13 x 10/sup -5/

  16. Communities with Source Separated Organics Programs, United States, 2015, EPA Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — This GIS dataset contains polygon features that represent communities with residential organics collection programs in the United States. EPA used US Census Bureau...

  17. Ventilation measurements as an adjunct to radon measurements in buildings

    International Nuclear Information System (INIS)

    Knutson, E.O.; Franklin, H.

    1977-01-01

    The concentration of radon in a building is a function of the radon sources within the building and of the building's ventilation characteristics. To complement its radon measurement program, HASL is currently assessing apparatus and procedures for measuring building ventilation. Results are reported from ventilation measurements made in the laboratory and in a residential building

  18. Role of EPA in Asset Management Research – The Aging Water Infrastructure Research Program

    Science.gov (United States)

    This slide presentation provides an overview of the EPA Office of Research and Development’s Aging Water infrastructure Research Program (AWIRP). The research program origins, goals, products, and plans are described. The research program focuses on four areas: condition asses...

  19. Contribution of radon and radon daughters to respiratory cancer

    International Nuclear Information System (INIS)

    Harley, N.; Samet, J.M.; Cross, F.T.; Hess, T.; Muller, J.; Thomas, D.

    1986-01-01

    This article reviews studies on the contribution of radon and radon daughters to respiratory cancer and proposes recommendations for further research, particularly a national radon survey. The steady-state outdoor radon concentration averages 200 pCi/m3, and indoor levels are about 4 times higher. The primary source of radon in homes is the underlying soil; entry depends on multiple variables and reduced ventilation for energy conservation increases indoor radon levels. Occupational exposures are expressed in units of radon daughter potential energy concentration or working level (WL). Cumulative exposure is the product of the working level and the time exposed. The unit for cumulative exposure is the working level month (WLM). The occupational standard for radon exposure is 4 WLM/year, and 2 WLM/year has been suggested as a guideline for remedial action in homes. Epidemiologic studies show that miners with cumulative radon daughter exposures somewhat below 100 WLM have excess lung cancer mortality. Some 3% to 8% of miners studied have developed lung cancer attributable to radon daughters. All of the underground mining studies show an increased risk of lung cancer with radon daughter exposure. All cell types of lung cancer increased with radon exposure. If radon and smoking act in a multiplicative manner, then the risk for smokers could be 10 times that for nonsmokers. The potential risk of lung cancer appears to be between 1 and 2 per 10,000/WLM, which yields a significant number of lung cancers as some 220 million persons in the United States are exposed on average to 10 to 20 WLM/lifetime

  20. Systematic measurements of the radon concentration indoor from Remetea, Harghita county

    International Nuclear Information System (INIS)

    Csegzi, Sandor

    2000-01-01

    Primary goal of the Remetea radon program was to carry out an indoor radon survey. The program can be applied too, in other places of the country. Remetea was built on volcanic rocks, where aligning of mineral water springs tells about the existence of geologic faulting. The 1992 census counted 2406 houses and 6550 residents of the village. The sample consisted of 120 houses chosen randomly from the entire stock. A hypergeometric statistical model has been used for sampling. Measurements were done in bedrooms at pillow level using etched track type Radamon radon detectors. Exposure lasted from January 1999 to July 1999. From the measurements it can be stated that the number of houses with radon concentration exceeding 200 Bq/m 3 is around 82. A high precision determination of activity has been done (errors under 3 %). Mapping indoor radon levels resembles the fault location that is indicated by springs and exhibited by geological studies. Particular points of the program were the soulful and self-aware approach the more than 30 schoolboys and girls participated, and the fact that the program met with a warm response from the public. (author)

  1. Radon in your dwellings - problems and mitigation

    International Nuclear Information System (INIS)

    Srivastava, D.S.

    2011-01-01

    The problem of radon in dwellings gained importance in 1984 after the Stanely Watra's house incidence in Pennsylvania USA. Since then several radon measuring techniques have been identified and instrumentations developed. National survey programs were started for monitoring radon levels in dwellings by Government authorities in all developed and developing countries including India. Successively, the measurement of thoron levels was also found desirable especially in high radiation background areas. A lot of work has been done since then by scientists and university researches and thousands of publications have been made in this field. Several developed countries have given guide lines for initiating action to reduce radon levels in dwellings if it is beyond 200-400 Bq/m 2 . The recommended 'action level' is found to depend upon the authorities making the recommendations. This talk is aimed to produce public awareness about the health hazard posed by concentration of naturally occurring radon gas in our dwellings, the sources of its production and mitigation of radon problem. The matter will be discussed in a general way using ppt presentation. (author)

  2. Radon and health

    International Nuclear Information System (INIS)

    Chobanova, Nina

    2016-01-01

    Radon is radioactive noble gas that can be found in soil, water, outdoor and indoor air. Since environmental radon on average accounts for about half of all human exposure to radiation from natural sources, increasing attention has been paid to exposure to radon and its associated health risks. Many countries have introduced regulations to protect their population from radon in dwellings and workplaces. In this article are discussed main characteristics of radon, including sources of exposure, variation in radon exposure, how managing risks from radon exposure, how to measure the concentration of radon. There are results of measurements conducted under the 'National radon programme' in Bulgaria also. Key words: radon, sources of exposure, risk, cancer, measure to decrease the concentration [bg

  3. Soil radon response around an active volcano

    International Nuclear Information System (INIS)

    Segovia, N.; Valdes, C.; Pena, P.; Mena, M.; Tamez, E.

    2001-01-01

    Soil radon behavior related to the volcanic eruptive period 1997-1999 of Popocatepetl volcano has been studied as a function of the volcanic activity. Since the volcano is located 60 km from Mexico City, the risk associated with an explosive eruptive phase is high and an intense surveillance program has been implemented. Previous studies in this particular volcano showed soil radon pulses preceding the initial phase of the eruption. The radon survey was performed with LR-115 track detectors at a shallow depth and the effect of the soil moisture during the rainy season has been observed on the detectors response. In the present state of the volcanic activity the soil radon behavior has shown more stability than in previous eruptive stages

  4. Comparison of radon and radon-daughter grab samples obtained during the winter and summer

    International Nuclear Information System (INIS)

    Karp, K.E.

    1987-08-01

    The Technical Measurements Center (TMC), under the auspices of the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) program, is investigating short-term methods for estimating annual average indoor radon-daughter concentrations (RDC). A field study at 40 sample locations in 26 residential structures in Grand Junction, Colorado, was conducted once in the winter and once in the summer. The short-term methods investigated as part of this study include ten-minute radon and radon-daughter grab sampling and hourly RDC measurements. The results of the field study indicate that ten-minute radon grab samples from basement locations are reproducible over different seasons during controlled sampling conditions. Nonbasement radon and RDC grab samples are highly variable even when the use of the location by the occupant is controlled and the ventilation rate is restricted. The grab sampling was performed under controlled occupied conditions. These results confirm that a short-term radon or RDC measurement in a nonbasement location in a house is not a standardized measurement that can be used to infer an annual average concentration. The hourly RDC measurements were performed under three sets of conditions over a 72-hour period. The three sets of conditions were uncontrolled occupied, controlled occupied, and controlled unoccupied. These results indicate that it is not necessary to relocate the occupants during the time of grab sampling. 8 refs., 8 figs., 10 tabs

  5. Predicting radon/radon daughter concentrations in underground mines

    International Nuclear Information System (INIS)

    Leach, V.A.

    1984-01-01

    A detailed description of a computer programme is outlined for the calculation of radon/radon daughter concentrations in air. This computer model is used to predict the radon/radon daughter concentrations in Working Level (WL) at the workplace and at the various junctions at either end of the branches in a typical ventilation network proposed for the Jabiluka mine in the Northern Territory

  6. Community-Based Investigation of Radon and Indoor Air Quality in Northeast Denver Neighborhoods

    Science.gov (United States)

    Pfotenhauer, D.; Iwasaki, P. G.; Ware, G. E.; Collier, A.; Hannigan, M.

    2017-12-01

    In 2015, Taking Neighborhood Health to Heart (TNH2H), a community-based organization based in Northeast Denver, and researchers from the University of Colorado, Boulder jointly piloted a project to investigate indoor air quality within Denver communities. This pilot study was carried out across 2015-2016 and found higher than actionable-levels for radon across a majority of its participants. These results inspired a continued collaboration between the community group and academic researchers from CU Boulder. The partnership went on to conduct a similar project this last year in which the team again employed a community-based participatory research (CBPR) framework to investigate indoor air pollutants across a broader geographical footprint in Denver's Northeast Neighborhoods. The collaboration sampled 30 participant houses across 5 neighborhoods for radon and volatile organic compounds (VOCs). Although VOC levels were found to be well under thresholds for concern, for the second year of this investigation, radon levels were found on average to be significantly above the EPA's threshold for hazardous levels. Additionally, in collecting survey data on the participants' house characteristics, certain identifiable trends emerged that signal which house types have greater risk of radon intrusion. Having found in two consecutive studies that a majority of homes in these neighborhoods are burdened with dangerous levels of radon, the partnership is now moving towards developing educational and political actions to address the results from these projects and disseminate the information regarding radon levels and threats to these neighborhood communities.

  7. 40 CFR 80.810 - Who shall register with EPA under the gasoline toxics program?

    Science.gov (United States)

    2010-07-01

    ... gasoline toxics program? 80.810 Section 80.810 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Toxics General Information § 80.810 Who shall register with EPA under the gasoline toxics program? (a) Refiners and importers...

  8. Radon in homes of the Portland, Oregon Area: Radon data from local radon testing companies collected by CRM (Continuous Radon Measurement) machines

    Science.gov (United States)

    Whitney, H.; Lindsey, K.; Linde, T.; Burns, S. F.

    2013-12-01

    Students from the Department of Geology at Portland State University paired up with the Oregon Health Authority to better understand radon gas values in homes of the Portland metropolitan area. This study focuses on radon values collected by continuous radon measurement (CRM) machines, taken by local radon testing companies. The local companies participating in this study include Alpha Environmental Services, Inc., Cascade Radon, Environmental Works, The House Detectives, LLC, and Soil Solutions Environmental Services, Inc. In total, 2491 radon readings spanning across 77 zip codes were collected from local companies in the Portland metropolitan area. The maximum value, average value, percentage of homes greater than 4 pCi/L and total rank sum was calculated and used to determine the overall radon potential for each zip code (Burns et al., 1998). A list and four maps were produced showing the results from each category. Out of the total records, 24 zip codes resulted in high radon potential and the average reading for the entire Portland Metropolitan area was 3.7 pCi/L. High potential zip codes are thought to be a result of sand and gravel (Missoula Flood deposits) and faults present in the subsurface. The CRM data was compared with both long-term and short-term data provided by the Oregon Health Authority to validate radon potentials in each zip code. If a home is located in a zip code with high or moderate radon potential across two types of data sets, it is recommended that those homes be tested for radon gas.

  9. Indoor radon measurements and methodologies in Latin American countries

    International Nuclear Information System (INIS)

    Canoba, A.; Lopez, F.O.; Arnaud, M.I.; Oliveira, A.A.; Neman, R.S.; Hadler, J.C.; Iunes, P.J.; Paulo, S.R.; Osorio, A.M.; Aparecido, R.; Rodriguez, C.; Moreno, V.; Vasquez, R.; Espinosa, G.; Golzarri, J.I.; Martinez, T.; Navarrete, M.; Cabrera, I.; Segovia, N.; Pena, P.; Tamez, E.; Pereyra, P.; Lopez-Herrera, M.E.; Sajo-Bohus, L.

    2001-01-01

    According to the current international guidelines concerning environmental problems, it is necessary to evaluate and to know the indoor radon levels, specially since most of the natural radiation dose to man comes from radon gas and its progeny. Several countries have established National Institutions and National Programs for the study of radon and its connection with lung cancer risk and public health. The aim of this work is to present the indoor radon measurements and the detection methods used for different regions of Latin America (LA) in countries such as Argentina, Brazil, Ecuador, Mexico, Peru and Venezuela. This study shows that the passive radon devices based on alpha particle nuclear track methodology (NTM) is one of the more generalized methods in LA for long term indoor radon measurements, CR-39, LR-115 and Makrofol being the more commonly used detector materials. The participating institutions and the radon level measurements in the different countries are presented in this contribution

  10. EPA Releases Guidance on a Voluntary Pilot Program to Reduce Animal Testing

    Science.gov (United States)

    EPA is announcing the start of a voluntary pilot program to evaluate the usefulness and acceptability of a mathematical tool that estimates the toxicological classification of a chemical, which is used in the GHS.

  11. Radon and radon daughters in public, private and commercial buildings in communities associated with uranium mining and processing in Canada

    International Nuclear Information System (INIS)

    Eaton, R.S.

    1982-01-01

    The elevated indoor radon levels in certain communities in Canada have been studied. An overview of the investigational and remedial action programs are presented in this paper. It is suggested that radon daughter concentrations can be controlled by: (a) removing source; (b) placing a barrier between the source and the living space; (c) diverting the radon before it enters a building: (d) increasing the ventilation rate. All methods have been proven but no one technique is the most cost effective because of widely varying conditions found in older housing

  12. Efficiency of radon reduction techniques and strategies

    International Nuclear Information System (INIS)

    Hubert, Ph.; Monchecourt, D.

    2000-01-01

    Radon is a lung carcinogen recognized by the World Health Organisation and it is present in dwellings. In France, the first actions to measure the exposition of the population were made in 1982, and the first national recommendation was published in 1999. In parallel, information booklets on radon and possible actions to lower its concentration in house were made available to the public. The aim of this study was to test the economic feasibility of different methods to reduce radon level in housing. The first step was to identify the cost and the radon reduction rate of different methods, all based on insulation or ventilation of the buildings. Using the data of the Environmental Protection Agency (EPA), we selected six measures and combined them to obtain a total of twenty potential solutions. We also used the 'duration' model of the Biological Effects of Ionising Radiation committee (BEIR VI) to determine the probability of dying from a cancer associated to a fixed exposure to radon. Knowing this information, it was possible to make cost-efficiency analysis on our data and thus keep six interesting methods. Combining these results with the value of human life of the human capital approach we could find what was the most interesting method to apply for a known level of radon and a specific duration of exposure in a house. In given house, for each level of initial exposure, a cost benefit approach allowed to determine if one, or several techniques, or none, is worthwhile to apply. In favorable cases (i.e : easily remediable houses), and with a figure for the price of human life of about 0,9 MEuro, actions should be undertaken at levels as low as 80 Bq.m -3 . As we know the radon distribution in France, the second step was to see what would be the effects on this distribution if all inhabitants used the optimal approach against their radon exposure defined by our function. Thus, overall costs and overall risks could be computed. However, in public health issues, the

  13. A study of radon 222 transfer indoors

    International Nuclear Information System (INIS)

    Maximilien, R.; Robe, M.C.; Archimbaud, M.

    1985-01-01

    Indoor exposure can vary considerably depending upon the natural environment (geology, climate), man-made arrangements (building materials, insulation and ventilation systems...) or way of living. In order to specify the sources and assess their respective contribution in a given dwelling, a good knowledge of radon transfer and dispersion processes is required as well as a heavy experimental device (continuous radon and ventilation monitoring...). The study must be limited to some cases selected by a systematic measurement program either because they are representative of dwelling conditions, or preferably on account of their high radon level, the origin of which will be investigated. As a consequence, countermeasures can be developed. A pilot study has been carried out on radon transport in two houses of the Rhone river valley. The two houses -selected among 131 other ones for their high radon levels- are built with the same architectural approach and located very close to each other, yet the factors accounting for domestic exposure are quite different. Indoor parameters are at the origin of various radon concentrations in the case of low natural ventilation; conversely, outdoor parameters only seem to act in the case of high ventilation. For a larger part, however, radon seems to emanate from under the foundations of both houses [fr

  14. Radon analyser

    International Nuclear Information System (INIS)

    1981-01-01

    The process claimed includes the steps of transferring radon gas produced by a sample to a charcoal trap, cooled to a temperature whereby the radon is absorbed by the charcoal, heating the charcoal trap to a sufficient temperature to release the radon, and transferring the radon to a counting device where the gas particles are counted

  15. U.S. EPA Superfund Program's Policy for Community Involvement at Radioactively Contaminated Sites

    International Nuclear Information System (INIS)

    Martin, K.; Walker, St.

    2009-01-01

    This paper describes the EPA Superfund program's statutory requirements for community involvement. It also discusses the efforts the Superfund program has made that go beyond these statutory requirements to involve communities, and what lessons have been learned by EPA when trying to conduct meaningful community involvement at sites. In addition, it discusses tools that EPA has designed to specifically enhance community involvement at radioactively contaminated Superfund sites. In summary, the Superfund program devotes substantial resources to involving the local community in the site cleanup decision making process. We believe community involvement provides us with highly valuable information that must be available to carefully consider remedial alternatives at a site. We also find our employees enjoy their jobs more. Rather than fighting with an angry public they can work collaboratively to solve the problems created by the hazardous waste sites. We have learned the time and resources we devote at the beginning of a project to developing relationships with the local community, and learning about their issues and concerns is time and resources well spent. We believe the evidence shows this up-front investment helps us make better cleanup decisions, and avoids last minute efforts to work with a hostile community who feels left out of the decision-making process. (authors)

  16. Protecting People and Families from Radon: A Federal Action Plan for Saving Lives

    Science.gov (United States)

    This strategy for radon action outlines actions federal agencies can take within existing resources and program capacities to advance the Healthy People 2020 radon objectives and launch a national effort to end all avoidable radon-induced lung cancer death

  17. Report: Environmental Job Training Program Implemented Well, But Focus Needed on Possible Duplication With Other EPA Programs

    Science.gov (United States)

    Report #12-P-0843, September 21, 2012. EPA effectively established and adhered to competitive criteria that resulted in the selection of job training proposals that addressed the broad goals of the Environmental Job Training program.

  18. Investigations of radon and radon daughters in surficial aquifers of florida

    International Nuclear Information System (INIS)

    1991-05-01

    The principal purpose of the investigation was to test the hypothesis that radon soil flux, considered the principal source of indoor radon contamination, has an underlying relationship to the radon content of associated shallow groundwaters. The working hypothesis was that radon build-up in both soil and shallow groundwater is basically a consequence of the same factor, radon emanation from soil grains and the solid surfaces of the aquifers. Groundwater may be advantageous as an indicator of radon potential. Another object of the project was to investigate temporal and spatial trends of radon daughter products in shallow aquifers. After analyzing all of the radon soil, flux, and groundwater measurements made over the two-year study period, it is clear that while there is no direct relationship between either radon soil concentration or flux and groundwater radon. Measurements in wells where polonium is present at very high concentrations have shown that 210Po is largely unsupported by its radioactive predecessor, and that polonium is considerably more variable, in both space and time than other parameters measured in the same wells, including radon

  19. Radon dosimetry: a review of radon and radon daughter exposure conditions in dwellings and other structures

    International Nuclear Information System (INIS)

    Ryan, M.T.; Goldsmith, W.A.; Poston, J.W.; Haywood, F.F.; Witherspoon, J.P.

    1983-07-01

    Within the past few years several situations have been brought to light which indicate an increased radiation exposure of certain segments of the general population caused by human activities. The most widely publicized activities are those associated with the mining and milling of uranium in the western United States, the phosphate industry in Florida, and those potential problems represented by former Manhattan Engineer District sites. One of the primary problems involves exposure to radon and radon daughters which are released from large waste piles or, in some cases, evolve from backfill and construction materials used in homes, schools, and other buildings. This report presents a review of the available data on radon and radon daughter concentrations in dwellings and other structures. The primary objectives were to compile and tabulate pertinent radon exposure data and to prepare a statistical summary of the data which will be useful in the prediction of normal levels of radon and radon daughter concentrations in these structures. In addition, other parameters associated with radon exposure conditions are presented and discussed

  20. Superfund Record of Decision (EPA Region 2): Montclair/West Orange, Radium, NJ. (First Remedial Action), June 1989

    International Nuclear Information System (INIS)

    1989-01-01

    The Montclair/West Orange Radium site is in the towns of Montclair and West Orange in Essex County, New Jersey. The soil at the site is contaminated with radioactive-waste materials suspected to have originated from radium processing or utilization facilities located nearby during the early 1900s. Temporary radon ventilation systems and gamma-radiation shielding have been installed and maintained by EPA and the State to reduce indoor exposures. The primary contaminant of concern affecting the soil and structures is radium 226 which decays to radon gas. The selected remedial action for the site includes excavation of approximately 41,000 cu yd of highly contaminated soil and an unspecified amount of debris followed by offsite disposal; installation and maintenance of indoor engineering controls at less contaminated properties; environmental monitoring to ensure remedy effectiveness; and continuation of a treatment technology study for future actions. EPA deferred a final continuation of a treatment-technology study for future action

  1. Background concentrations of radon and radon daughters in Canadian homes

    International Nuclear Information System (INIS)

    McGregor, R.G.; Vasudev, P.; Letourneau, E.G.; McCullough, R.S.; Prantl, F.A.; Taniguchi, H.

    1980-01-01

    Measurements of radon and radon daughters were carried out in 14 Canadian cities on a total of 9999 homes selected in a statistically random manner. The geometric means of the different cities varied from 0.14 to 0.88 pCi/l. for radon and 0.0009 to 0.0036 Working Levels for radon daughters. The radon originates from natural radioactivity in the soil surrounding the homes. (author)

  2. Experimental, statistical, and biological models of radon carcinogenesis

    International Nuclear Information System (INIS)

    Cross, F.T.

    1991-09-01

    Risk models developed for underground miners have not been consistently validated in studies of populations exposed to indoor radon. Imprecision in risk estimates results principally from differences between exposures in mines as compared to domestic environments and from uncertainties about the interaction between cigarette-smoking and exposure to radon decay products. Uncertainties in extrapolating miner data to domestic exposures can be reduced by means of a broad-based health effects research program that addresses the interrelated issues of exposure, respiratory tract dose, carcinogenesis (molecular/cellular and animal studies, plus developing biological and statistical models), and the relationship of radon to smoking and other copollutant exposures. This article reviews experimental animal data on radon carcinogenesis observed primarily in rats at Pacific Northwest Laboratory. Recent experimental and mechanistic carcinogenesis models of exposures to radon, uranium ore dust, and cigarette smoke are presented with statistical analyses of animal data. 20 refs., 1 fig

  3. Testing of indoor radon reduction techniques in eastern Pennsylvania: An update

    International Nuclear Information System (INIS)

    Henschel, D.B.; Scott, A.G.

    1987-01-01

    EPA has installed radon reduction measures in 38 houses in the Reading Prong region of eastern Pennsylvania. All were basement houses with hollow block or poured concrete foundation walls. The reduction approaches tested in most houses involved active soil ventilation, including: suction on the footing drain tile system; suction underneath the concrete slabs, using pipes inserted through the slabs from inside the house; and ventilation of the void network inside hollow block foundation walls. Heat recovery ventilators (HRVs) were tested in three houses. The current results confirm that, for the houses tested here, drain tile suction appears consistently able to provide high radon reductions when a complete loop of drain tile exists, often reducing high-radon houses to 4 pCi/l (148 B1/m 3 ) and less. Sub-slab suction (with pipes through the slab) can also provide high reductions if a sufficient number of suction pipes are located properly. Placement of one or more sub-slab suction pipes near each perimeter wall appears in this testing to aid in treating the major soil gas entry routes, although fewer pipes can sometimes give high reductions if conditions are favorable. For effective radon reduction using any active soil ventilation technique, it is important that major wall and slab openings be closed, and that a fan be employed that is capable of developing adequate static pressure

  4. Radon in public buildings; Radon in oeffentlichen Gebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, H.; Flesch, K. [IAF - Radiooekologie GmbH, Dresden (Germany); Hermann, E. [B.P.S. Engineering GmbH, Zwickau (Germany); Loebner, W. [Wismut GmbH, Chemnitz (Germany); Leissring, B. [Bergtechnisches Ingenieurbuero GEOPRAX, Chemnitz (Germany)

    2009-07-01

    From the Free State of Saxony, a study was commissioned to survey how reliable measurements to characterize the radon situation in public buildings at a reasonable financial and human effort can be carried out to reduce radiation exposure in public buildings. The study approach was for 6 objects. To characterize the radon situation the time evolution measurement of radon concentrations of more than 1 to 2 weeks turned out to be sufficient. A novel data analysis enables the identification of a ''typical daily alteration of the radon concentration'' depending on the ventilation conditions and the daily use of the offices or class rooms. The identification of typical diurnal radon variations for the working time and weekends or holidays is of fundamental importance for assessing the exposure situation in public buildings. It was shown that the radon concentration during working time are in general much lower than in the times when the buildings (offices) are unused. It turned out that the long-term radon measurements with nuclear track detectors within distinct time regimes (day / night, working hours / leisure time) by utilizing switch modules are very efficient to estimate the actual exposure. (orig.)

  5. Long term and equilibrium factor indoor radon measurements

    International Nuclear Information System (INIS)

    Martinez, T.; Lartigue, J.; Navarrete, M.; Cabrera, L.; Ramirez, A.; Elizarraras, V.

    1998-01-01

    This paper presents the annual radon gas concentrations obtained during the 1994-1995 monitoring campaign using passive electret system (type E-PERM). Radon levels were measured in 154 single family dwellings, in normal occupancy conditions (open house condition) in the metropolitan zone of Mexico City. At the same time radon monitoring was performed outdoors. The results show the general log-normal distribution of integrated indoor radon concentration with an annual indoor mean of 3.8 pCi x l -1 . The seasonal variations show the minimum mean values in the summer season which are 39% lower than that in autumn. Equilibrium factors (F) were measured in 12 typical houses both in autumn and winter using a continuous working level monitor for short-lived radon decay products and H-chamber loaded with a short term electret (HST, E-PERM) for radon gas. The obtained total mean equilibrium factors are: F=0.41±0.17 and F=0.29±0.04 for indoor and outdoor, respectively. A quality program was also improved. (author)

  6. Radon in Austria

    International Nuclear Information System (INIS)

    Friedmann, H.

    2000-01-01

    Several projects in Austria deal with the problem of enhanced radon exposure to the public. The Austrian Radon Project is the largest project within this task, with the aim of investigating the radon concentrations in Austrian homes. Another project concerns mitigation methods. According to the EU directive EURATOM 96/29 it is also necessary to check working places for possibly enhanced radon concentrations. These projects are and will be funded by the government. The federal government of Upper Austria sponsored a project to test the indoor air quality in kindergartens including radon measurements. Within an EU research project, the radon concentrations in Austrian springs and groundwater were systematically listed and analyzed. Additional investigations will focus on methods to improve the radon potential maps from the Austrian Radon Project by including geological and other information. (author)

  7. Measurements of indoor radon and radon progeny in Mexico City

    International Nuclear Information System (INIS)

    Cheng, Y.S.; Rodriguez, G.P.

    1996-01-01

    Indoor radon has been a public concern associated with increased lung cancer risks. Radon decay products interact with indoor aerosols to form progeny with different size distributions, which may influence the lung dosimetry when the progeny are inhaled. Air pollution in Mexico City is a serious problems with high particulate concentrations, but there are few reports of indoor radon measurement. The purposes of this study were to measure the aerosol concentration, radon concentration, and radon activity size distribution in the living area of three houses in Mexico City. The radon concentration was monitored by a RGM-3 radon gas monitor (Eberline, Inc., Santa Fe, NM). A graded diffusion battery was used to determine the progeny concentration and activity size distribution. The concentration and size distribution of the indoor aerosols were monitored by a quartz, crystal microbalance cascade impactor. Our measurements showed high concentrations of indoor aerosols (20-180 gg m -3 ). However, the radon concentrations-were low ( -1 ), but showed a clear diurnal pattern with peak concentrations from 2-10 AM. The activity size distributions of radon progeny were trimodal, with peaks of 0.6 nm, 4-5 nm, and 100 rim. Most activities were associated with large particle sizes. Our results indicated that indoor radon concentration was not high, due in part to a relatively high air exchange with outdoor air. The high aerosol concentration may also play an important part in the activity size distribution of radon progeny

  8. Use of a geographic information system (GIS) for targeting radon screening programs in South Dakota

    International Nuclear Information System (INIS)

    Kearfott, Kimberlee J.; Whetstone, Zachary D.; Mir, Khwaja M. Rafique

    2016-01-01

    Because 222 Rn is a progeny of 238 U, the relative abundance of uranium may be used to predict the areas that have the potential for high indoor radon concentration and therefore determine the best areas to conduct future surveys. Geographic Information System (GIS) mapping software was used to construct maps of South Dakota that included levels of uranium concentrations in soil and stream water and uranium deposits. Maps of existing populations and the types of land were also generated. Existing data about average indoor radon levels by county taken from a databank were included for consideration. Although the soil and stream data and existing recorded average indoor radon levels were sparse, it was determined that the most likely locations of elevated indoor radon would be in the northwest and southwest corners of the state. Indoor radon levels were only available for 9 out of 66 counties in South Dakota. This sparcity of data precluded a study of correlation of radon to geological features, but further motivates the need for more testing in the state. Only actual measurements should be used to determine levels of indoor radon because of the strong roles home construction and localized geology play in radon concentration. However, the data visualization method demonstrated here is potentially useful for directing resources relating to radon screening campaigns. (author)

  9. Radon and radon daughters in South African underground mines

    International Nuclear Information System (INIS)

    Rolle, R.

    1980-01-01

    Radon and the radon daughters are the radionuclides which primarily determine the level of the radiation hazard in underground uranium mines and to a smaller extent in non-uranium mines. Radon is a gas, and its daughters adsorb on aerosol particles which are of respirable size. The hazard thus arises from the alpha decay of radon and its daughters in contact with lung tissue. Radon is itself part of the uranium decay chain. The major radionuclide, 238 U, decays successively through thirteen shorter-lived radionuclides to 206 Pb. Radon is the only gaseous decay product at room temperature; the other twelve are solids. The main hazard presented by the uranium decay chain is normally determined by the radon concentration because gaseous transport can bring alpha emitters close to sensitive tissue. There is no such transport route for the other alpha emitters, and the level of beta and gamma radiation caused by the uranium decay chain generally presents a far lower external radiation hazard. Radon itself is the heaviest of the noble gases, which are He, Ne, Ar, Kr, Xe and Rn. Its chemical reactions are of no concern in regard to its potential hazard in mines as it may be considered inert. It does, however, have a solubility ten times higher than oxygen in water, and this can play a significant part in assisting the movement of the gas from the rock into airways. Radon continuously emanates into mine workings from uranium ores and from the uranium present at low concentrations in practically any rock. It has been found that the control of the exposure level is most effectively achieved by sound ventilation practices. In South African mines the standard of ventilation is generally high and exposure to radon and radon daughters is at acceptably low levels

  10. Evaluation of strategies for promoting effective radon mitigation. Risk communication and economic research series. Final report

    International Nuclear Information System (INIS)

    Doyle, J.K.; McClelland, G.H.; Schulze, W.D.; Locke, P.A.; Elliott, S.R.

    1990-03-01

    The Environmental Protection Agency has estimated that as many as 20,000 lung cancer deaths per year in the United States can be attributed to exposure to radon gas. The report evaluates alternative strategies for motivating people to test for radon gas in their homes and to mitigate if necessary. Specifically, two separate radon information and awareness programs were evaluated, one targeted to the general population in the Washington, D.C. area and the other to home buyers in the Boulder, Colorado area. The results suggest that a home buyer program is likely to be far more effective in terms of effective remediation to reduce home radon levels than a program aimed at the general population. The report discusses the empirical findings and develops a recommendation for increasing the effectiveness of radon awareness and mitigation programs

  11. EPA for Businesses and Non-Profits

    Science.gov (United States)

    Information and links to EPA web pages that are meant to help businesses and non-profits adhere to EPA regulations and otherwise protect the environment, take advantage of opportunities to collaborate with the EPA, and find training EPA training programs.

  12. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    International Nuclear Information System (INIS)

    Baumgartner, A.; Maringer, F.J.; Michai, P.; Kreuziger, M.

    2006-01-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  13. Improved radon-flux-measurement system for uranium-tailings pile measurement

    International Nuclear Information System (INIS)

    Freeman, H.D.

    1981-10-01

    The Pacific Northwest Laboratory (PNL) is developing cover technology for uranium mill tailings that will inhibit the diffusion of radon to the atmosphere. As part of this cover program, an improved radon flux measurement system has been developed. The radon measurement system is a recirculating, pressure-balanced, flow-through system that uses activated carbon at ambient temperatures to collect the radon. With the system, an area of 0.93 m 2 is sampled for periods ranging from 1 to 12 h. The activated carbon is removed from the radon trap and the collected radon is determined by counting the 214 Bi daughter product. Development of the system included studies to determine the efficiency of activated carbon, relative calibration measurements and field measurements made during 1980 at the inactive tailings pile in Grand Junction, Colorado. Results of these studies are presented

  14. Computer program for the sensitivity calculation of a CR-39 detector in a diffusion chamber for radon measurements

    Energy Technology Data Exchange (ETDEWEB)

    Nikezic, D., E-mail: nikezic@kg.ac.rs; Stajic, J. M. [Faculty of Science, University of Kragujevac, R. Domanovica 12, Kragujevac 34000 (Serbia); Yu, K. N. [Department of Physics and Materials Science, City University of Hong Kong, 83 Tat Chee Avenue (Hong Kong)

    2014-02-15

    Computer software for calculation of the sensitivity of a CR-39 detector closed in a diffusion chamber to radon is described in this work. The software consists of two programs, both written in the standard Fortran 90 programming language. The physical background and a numerical example are given. Presented software is intended for numerous researches in radon measurement community. Previously published computer programs TRACK-TEST.F90 and TRACK-VISION.F90 [D. Nikezic and K. N. Yu, Comput. Phys. Commun. 174, 160 (2006); D. Nikezic and K. N. Yu, Comput. Phys. Commun. 178, 591 (2008)] are used here as subroutines to calculate the track parameters and to determine whether the track is visible or not, based on the incident angle, impact energy, etching conditions, gray level, and visibility criterion. The results obtained by the software, using five different V functions, were compared with the experimental data found in the literature. Application of two functions in this software reproduced experimental data very well, while other three gave lower sensitivity than experiment.

  15. Report: EPA Improved Its National Security Information Program, but Some Improvements Still Needed

    Science.gov (United States)

    Report #16-P-0196, June 2, 2016. The EPA will continue to improve its national security information program by completing information classification guides that can be used uniformly and consistently throughout the agency.

  16. Use of a geographic information system (GIS) for targeting radon screening programs in South Dakota.

    Science.gov (United States)

    Kearfott, Kimberlee J; Whetstone, Zachary D; Rafique Mir, Khwaja M

    2016-01-01

    Because (222)Rn is a progeny of (238)U, the relative abundance of uranium may be used to predict the areas that have the potential for high indoor radon concentration and therefore determine the best areas to conduct future surveys. Geographic Information System (GIS) mapping software was used to construct maps of South Dakota that included levels of uranium concentrations in soil and stream water and uranium deposits. Maps of existing populations and the types of land were also generated. Existing data about average indoor radon levels by county taken from a databank were included for consideration. Although the soil and stream data and existing recorded average indoor radon levels were sparse, it was determined that the most likely locations of elevated indoor radon would be in the northwest and southwest corners of the state. Indoor radon levels were only available for 9 out of 66 counties in South Dakota. This sparcity of data precluded a study of correlation of radon to geological features, but further motivates the need for more testing in the state. Only actual measurements should be used to determine levels of indoor radon because of the strong roles home construction and localized geology play in radon concentration. However, the data visualization method demonstrated here is potentially useful for directing resources relating to radon screening campaigns. © The Author 2015. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  17. Comparability between NQA-1 and the QA programs for analytical laboratories within the nuclear industry and EPA hazardous waste laboratories

    International Nuclear Information System (INIS)

    English, S.L.; Dahl, D.R.

    1989-01-01

    There is increasing cooperation between the Department of Energy (DOE), Department of Defense (DOD), and the Environmental Protection Agency (EPA) in the activities associated with monitoring and clean-up of hazardous wastes. Pacific Northwest Laboratory (PNL) examined the quality assurance/quality control programs that the EPA requires of the private sector when performing routine analyses of hazardous wastes to confirm how or if the requirements correspond with PNL's QA program based upon NQA-1. This paper presents the similarities and differences between NQA-1 and the QA program identified in ASTM-C1009-83, Establishing a QA Program for Analytical Chemistry Laboratories within the Nuclear Industry; EPA QAMS-005/80, Interim Guidelines and Specifications for Preparing Quality Assurance Project Plans, which is referenced in Statements of Work for CERCLA analytical activities; and Chapter 1 of SW-846, which is used in analyses of RCRA samples. The EPA QA programs for hazardous waste analyses are easily encompassed within an already established NQA-1 QA program. A few new terms are introduced and there is an increased emphasis upon the QC/verification, but there are many of the same basic concepts in all the programs

  18. EPA [Environmental Protection Agency] SITE [Superfund Innovative Technology Evaluation] program seeks technology proposals

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    EPA will issue an RFP to initiate the SITE-005 solicitation for demonstration of technologies under the Superfund Innovative Technology Evaluation (SITE) Program. This portion of the SITE program offers a mechanism for conducting a joint technology demonstration between EPA and the private sector. The goal of the demonstration program is to provide an opportunity for developers to demonstrate the performance of their technologies on actual hazardous wastes at Superfund sites, and to provide accurate and reliable data on that performance. Technologies selected must be of commercial scale and provide solutions to problems encountered at Superfund Sites. Primary emphasis in the RFP is on technologies that address: treatment of mixed, low level radioactive wastes in soils and groundwater; treatment of soils and sludges contaminated with organics and/or inorganics, materials handling as a preliminary step to treatment or further processing, treatment trains designed to handle specific wastes, are in situ technologies, especially those processes providing alternatives to conventional groundwater pump and treat techniques

  19. Indoor radon

    International Nuclear Information System (INIS)

    1997-12-01

    The radon, a natural radioactive gas, is present almost everywhere on the earth's surface. It can be accumulated at high concentration in confined spaces (buildings, mines, etc). In the last decades many studies conducted in several countries showed that inhaling important amounts of radon rises the risk of lung cancer. Although, the radon is a naturally appearing radioactive source, it may be the subject of a human 'enhancement' of concentration. The increasing radon concentration in professional housing constitutes an example of enhanced natural radioactivity which can induce health risks on workers and public. Besides, the radon is present in the dwelling houses (the domestic radon). On 13 May 1996, the European Union Council issued the new EURATOM Instruction that establishes the basic standards of health protection of population and workers against the ionizing radiation hazards (Instruction 96/29/EURATOM, JOCE L-159 of 29 June 1996). This instruction does not apply to domestic radon but it is taken into consideration by another EURATOM document: the recommendation of the Commission 90/143/EURATOM of 21 February 1990 (JOCE L-80 of 27 March 1990). The present paper aims at establishing in accordance to European Union provisions the guidelines for radon risk management in working places, as well as in dwelling houses, where the implied risk is taken into account. This document does not deal with cases of high radon concentration on sites where fabrication, handling or storage of radium sources take place. These situations must be treated by special studies

  20. Measurements of Indoor Radon Concentrations in Chaiya and Tha Chana Districts, Surat Thani Province, Thailand

    International Nuclear Information System (INIS)

    Titipornpun, K.; Titipornpun, A.; Sola, P.; Bhongsuwan, T.

    2014-01-01

    Chaiya and Tha Chana districts of Surat Thani province are located in the areas with high equivalent uranium at ground surface, which have been identified as sources of radon. A survey measurement of indoor radon concentrations was carried out in 248 houses, using CR-39 detectors in closed cups. All of the detectors were exposed to radon for forty days. After the exposure, the alpha tracks were made visible by chemical etching and counted manually under an optical microscope. The indoor concentrations in Chaiya district were found to vary from the minimum to the maximum of 4 Bq.m -3 to 88 Bq.m -3 , respectively. In Tha Chana district, the concentrations of indoor radon were varied from the minimum of 4 Bq.m -3 to the maximum of 159 Bq.m -3 . The geometric mean of indoor radon concentrations in Chaya and Tha Chana districts were found to be 26±2 Bq.m -3 and 30±2 Bq.m -3 , respectively. The overall geometric mean in the surveyed areas was 28±2 Bq.m -3 . Only in two houses (1%), the concentrations (151 and 159 Bq.m -3 ) were found to be higher than the action level recommended by the US EPA (148 Bq.m -3 ). Most houses (94%) have natural ventilation by keeping doors and windows opened during the daytime. This ventilation likely causes the low level of indoor radon concentrations.

  1. Mechanisms of radon injury

    International Nuclear Information System (INIS)

    Cross, F.T.

    1988-01-01

    In this new project, they conduct molecular, cellular and whole-animal research relevant to understanding the inhalation toxicology of radon and radon-daughter exposures. The work specifically addresses the exposure-rate effect in radon-daughter carcinogenesis; the induction-promotion relationships associated with exposure to radon and cigarette-smoke mixtures; the role of oncogenes in radon-induced cancers; the effects of radon on DNA as well as on DNA repair processes; and the involvement of growth factors and their receptors in radon-induced carcinogenesis. Preliminary experiments showed that oncogenes are activated in radon-induced lung tumors. They have therefore begun further exposures pertinent to the oncogene and growth-factor studies. An in vitro radon cellular-exposure system was designed, and cell exposures were initiated. Initiation-promotion-initiation studies with radon and cigarette-smoke mixtures have also begun; and they are compiling a radon health-effects bibliography

  2. 1992 update of US EPA's Superfund Innovative Technology Evaluation (SITE) Emerging Technology Program

    International Nuclear Information System (INIS)

    Lewis, N.M.; Barkley, N.P.; Williams, T.

    1992-01-01

    The Superfund Innovative Technology Evaluation (SITE) Emerging Technology Program (ETP) has financially supported further development of bench- and pilot-scale testing and evaluation of innovative technologies for use at hazardous waste sites for five years. The ETP was established under the Superfund Amendments and Reauthorization Act (SARA) of 1986. The ETP complies with the goal of the SITE Program to promote, accelerate and make commercially available the development of alternative/innovative treatment technologies for use at Superfund sites. Technologies are submitted to the ETP through yearly solicitations for Preproposals. Applicants are asked to submit a detailed project proposal and a cooperative agreement application that requires Developer/EPA cost sharing. EPA co-funds selected Developers for one to two years. Second-year funding requires documentation of significant progress during the first year. Facilities, equipment, data collection, performance and development are monitored throughout the project. The US Department of Energy (DOE) and the US Air Force (USAF) are participants in the ETP. DOE has co-funded ETP projects since 1990 and the USAF since 1991. A goal of the ETP is to move developed technologies to the field-demonstration stage. A developer may be considered for participation in the SITE Demonstration Program if performance in the ETP indicates the technology is field-ready for evaluation. Six technology categories: biological, chemical, materials handling, physical, solidification/stabilization and thermal, are presently in the ETP. Technologies of primary interest to EPA are those that can treat complex mixtures of hazardous organic and inorganic contaminants and provide improved solids handling and/or pretreatment. An account of the background and progress of the ETP's first five years is presented in this paper. Technologies currently in the ETP are noted, and developers and EPA Project Managers, are listed. 4 refs., 11 figs., 6 tabs

  3. Evaluation of experiences in long-term radon and radon-daughter measurements

    International Nuclear Information System (INIS)

    Young, J.A.; Jackson, P.O.; Thomas, V.W.

    1982-12-01

    Pacific Northwest Laboratory (PNL) is performing side-by-side measurements of radon and radon daughter concentrations using several instruments and techniques, and is comparing these measurements with side-by-side measurements made by other investigators at other locations. The standard deviation of the differences between the (natural) logarithms of the Terradex Track Etch radon concentrations and the logarithms of the Radon Progency Integrating Sampling Units (RPISU) radon daughter concentrations (S.D.-ln) measured in 50 buildings in Edgemont, South Dakota, was 0.37. Using this S.D.-ln, it can be calculated that if the Track Etch radon daughter concentration is 0.010 WL there should be only a 14% probability that the RPISU average would be greater than 0.015 WL, and only a 3% probability tht the RPISU average would be greater than 0.020 WL. If buildings had been cleared from remedial action when the Track Etch averages were less than 0.10 WL, then about 61% of the buildings would have been cleared from remedial action, and only a few percent of these buildings would have actually had average RPISU concentrations greater than 0.015 WL. The S.D.-ln between the Track Etch radon measurements and the RPISU radon daughter measurements made by ALARA at Grand Junction, the PERM radon measurements and the MOD-225 radon daughter measurements made by Mound Facility at Canonsburg and Middlesex, and the PERM and Track Etch radon measurements made by Mound Facility at Salt Lake City were similar to the S.D.-ln between the Track Etch radon measurements and the RPISU radon daughter measurements at Edgemont

  4. Mapping the geogenic radon potential of the eastern Canary Islands.

    Science.gov (United States)

    Rubiano, Jesús G.; Alonso, Hector; Arnedo, Miguel. A.; Tejera, Alicia; Martel, Pablo; Gil, Juan M.; Rodriguez, Rafael; González, Jonay

    2014-05-01

    using a calibrated nomogram. As results, maps of radon in soils have been developed for the three islands to identify areas where may appear high activity concentrations of radon due to natural sources. Finally to determine the radon potential of soils analyzed we applied a procedure to classify the radon areas in several levels of risk using the measured values of radon activity concentration and soil permeability. Acknowledgments: This work was financed by the Nuclear Safety Council (CSN) through a grant in its R&D program 2009 and by the European Development Fund (ERDF) through a research project program 2007 granted by Canary Agency for Research, Innovation and Information Society (ACIISI) of the Canary Islands.

  5. A novel design for construction of dwellings in radon prone areas of Ramsar

    International Nuclear Information System (INIS)

    Mortazavi, S.M.J.; Kazemi, E.; Nowrouzi, S.; Abdollahi, H.; Mortazavi, S.A.

    2010-01-01

    Radon can accumulate in residential places at sufficiently high levels. Indoor radon levels in some regions of Ramsar are up to 3700 Bq m -3 , a concentration that is much higher than US EPA recommended action level of 148 Bq m -3 (4 pCi/L). Radon is the 2 nd leading cause of lung cancer, after cigarette smoking. It is widely believed that there is no threshold for lung cancer from radon exposure. In this study after reviewing the meteorological changes of Ramsar over the past 50 years (1955-2005), a novel design for constructing dwellings in radon prone areas is introduced. Natural ventilation is a type of ventilation that is created by the differences in the distribution of air pressures around a building. The basic element of our design is enhancement of natural ventilation by making wind and chimney effect to move fresh air through dwellings. The buoyancy effect caused by temperature differences makes air flow. The size and location of openings in each dwelling determine the extent of natural ventilation. In our two-storey house model, wind speed and direction, relative humidity, average temperature, and especially the traditional architecture of the northern coastal part of Iran, are taken into account. Furthermore, in this model, windows and skylights, evergreen or deciduous trees and fireplace chimneys as well as construction materials and wall coverings are the key components of the natural ventilation system. (author)

  6. Some results from the demonstration of indoor radon reduction measures in block basement houses

    International Nuclear Information System (INIS)

    Henschel, D.B.; Scott, A.G.

    1989-01-01

    Active soil ventilation techniques have been tested in 26 block-wall basement houses in eastern Pennsylvania with significantly elevated indoor radon concentrations, generally above 740 Bq/m 3 , and the results indicate that radon levels can be reduced substantially often below the U.S. Environmental Protection Agency (EPA) guideline of 148 Bq/m 3 , if effective suction can be drawn on the soil underneath the concrete slabs of these houses. Such effective suction appears achievable when either: (1) the house has a complete loop of drain tile around its footings for water drainage purposes, and suction is drawn on that loop; or (2) a sufficient number of suction pipes can be inserted at the proper locations into the crushed rock or the soil underneath the slab

  7. Construction of radon/radon daughter calibraton chamber

    International Nuclear Information System (INIS)

    Fry, J.; Gan, T.H.; Leach, V.A.; Saddlier, J.; Solomon, S.B.; Tam, K.K.; Travis, E.; Wykes, P.

    1983-01-01

    The radon/radon daughter test chamber is a copper lined room 1.65x1.75x2.75m with an effective volume of 8000 litres. The air residence time is controlled by circulating the air in the chamber through absolute filters which remove 99.9% of particulates. Radon is drawn into the chamber from a 17 μCi 226 RaCl source using the pressure differential across the blowers (<3 psi)

  8. A technical evaluation of the EDA radon gas continuous monitoring system

    International Nuclear Information System (INIS)

    Bigu, J.

    1979-04-01

    Extensive laboratory and underground tests were conducted with a radon gas continuous monitoring system built by EDA Instruments Inc. The system consists of several remote radon gas sensors linked via signal cables to a central control unit that fully controls the operation of the radon monitors. The system enables four operations to be performed: sampling, background, flush and bypass. The sequence and duration of these functions is programmable. Up to 20 functions in any desired pattern each lasting from 1 min to 23 hr 59 min can be programmed. Several programs were used during the experiments in order to obtain radon and thoron gas levels. The performance of the EDA system was quite satisfactory. It is suggested that ruggedization as well as some other modifications be introdouced into the system to: a) better withstand the harsh underground environment; and b) improve its performance

  9. Application of single-chip microcomputer to portable radon and radon daughters monitor

    International Nuclear Information System (INIS)

    Meng Yecheng; Huang Zhanyun; She Chengye

    1992-01-01

    Application of single-chip microcomputer to portable radon and radon daughters monitor is introduced in this paper. With the single-chip microcomputer automation comes into effect in the process from sampling to measuring of radon and radon daughters. The concentrations of radon and radon daughters can be easily shown when the conversion coefficients are pre-settled before the measurement. Moreover, the principle and design are briefly discussed according to the characteristics of the monitor

  10. Compact detector for radon and radon daughter products

    International Nuclear Information System (INIS)

    Alter, H.W.; Oswald, R.A.

    1986-01-01

    This invention provides an improved compact track registration detector for radon gas. The detector comprises a housing having an open mouth, a bottom, and side walls; track registration means, supported inside the housing, which forms damage tracks along paths traversed by alpha particles; a microporous filter positioned across the mouth of the housing to prevent entry of radon daughters and particulate matter; and a cap that may be placed on the mouth of the housing to retain the filter. The housing has internal wall surfaces dimensioned to optimize the registration of alpha particles from radon and radon daughters present in the housing

  11. Theoretical and experimental study of radon measurement with designing and calibration domestic canister with active charcoal

    International Nuclear Information System (INIS)

    Urosevic, V.; Nikezic, D.; Zekic, R.

    2005-01-01

    Radon concentration in air may change significantly large variation due to atmospheric variation. Measurement with active charcoal can be inaccurate because the variation in radon concentration. We made model to simulate radon measurements with active charcoal in order to optimize and improve integration characteristic. A numerical method and computer code based on the method of finite elements is developed for the case of variable radon concentration in air. This program simulates radon adsorption by the activated charcoal bed, enabling determination of sensitivity. The dependence of sensitivity on different parameters, such as temperature, thickness of the charcoal, etc. was studied using this program. Using results of theoretical investigation we designed and calibrated our canister with active charcoal for radon measurements. (author)

  12. The use of soil gas as radon source in radon chambers

    International Nuclear Information System (INIS)

    Al-Azmi, Darwish

    2009-01-01

    A procedure is described in which soil gas is utilized as an alternative to the 226 Ra source for the supply of the radon gas required to fill a radon chamber where radon-measuring devices are calibrated. The procedure offers opportunities to vary the radon concentration within the chamber around an average value of about 500 Bq/m 3 , which is considered to be sufficient for calibrating indoor radon detectors. The procedure is simple and the radon source does not require radiation protection certification (for import and/or use), unlike the commercially produced standard radioactive ( 226 Ra) sources.

  13. Radon in Antarctica

    International Nuclear Information System (INIS)

    Ilic, R.; Rusov, V.D.; Pavlovych, V.N.; Vaschenko, V.M.; Hanzic, L.; Bondarchuk, Y.A.

    2005-01-01

    The paper reviews results of radon measurements obtained in Antarctic research stations in the last 40 years by both active and passive radon monitors. A brief description of the radon laboratory set-up in the Ukrainian Academician Vernadsky station on the Antarctic Peninsula (W 64 o 16 ' , S 65 o 15 ' ), where radon is measured by two types of etched track Rn dosimeter and 4 types of continuous radon monitoring devices is presented. Some selected results of research work are described related to: (i) analysis of radon storms, defined as an abrupt increase of 222 Rn during the occurrence of a cyclone, and its applicability for the study of the transport of air masses of continental origin to Antarctica; (ii) a study of the correlation of changes of radon concentration and geomagnetic field induced by tectonic activity and its application to predicting tectonomagnetic anomalies, and (iii) verification of a newly developed theoretical model based on noise analysis of the measured radon signal for earthquake prediction. Suggestions for future utilization of radon for basic research in Antarctica (and not only in Antarctica) conclude the contribution. conclude the contribution

  14. Radon concentrations in contaminated and uncontaminated premises in two Ontario towns

    International Nuclear Information System (INIS)

    Aitken, J.H.; Baker, E.G.; Chatterjee, R.M.; Kusiak, R.; Tai-Pow, J.

    1977-01-01

    Radon-222 concentrations in air were measured by grab sampling in a large number of private homes and other buildings in the town of Port Hope, Ontario. The purpose of the measurements is to identify places where a health hazard might exist due to improper disposal of radium-contaminated materials. Contaminated fill, rubble, lumber, and other building materials have been found in a number of premises in the town. Radon concentrations up to 750 pCi/l have been found in some homes. The thrust of the program is to identify quickly places where concentrations might be high enough to justify some prompt interim remedial action such as installation of special ventilation systems, pending final remedial work by removal of the contamination. The methods and instrumentation immediately available are those formerly used for radon-in-breath analysis in radium workers. Grab sampling for radon and gamma surveying in every building in town are used together in a screening program. Experience showed that both radon sampling and gamma surveying are required to identify contaminated locations

  15. Radon-Instrumentation; Radon-Instrumentacion

    Energy Technology Data Exchange (ETDEWEB)

    Moreno y Moreno, A. [Departamento de Apoyo en Ciencias Aplicadas, Benemerita Universidad Autonoma de Puebla, 4 Sur 104, Centro Historico 72000 Puebla (Mexico)

    2003-07-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  16. US EPA Region 4 Brownfields

    Science.gov (United States)

    To improve public health and the environment, the United States Environmental Protection Agency (USEPA) collects information about facilities, sites, or places subject to environmental regulation or of environmental interest. Through the Geospatial Data Download Service, the public is now able to download the EPA Geodata shapefile containing facility and site information from EPA's national program systems. The file is Internet accessible from the Envirofacts Web site (https://www3.epa.gov/enviro/). The data may be used with geospatial mapping applications. (Note: The shapefile omits facilities without latitude/longitude coordinates.) The EPA Geospatial Data contains the name, location (latitude/longitude), and EPA program information about specific facilities and sites. In addition, the file contains a Uniform Resource Locator (URL), which allows mapping applications to present an option to users to access additional EPA data resources on a specific facility or site. This dataset shows Brownfields listed in the 2012 Facility Registry System.

  17. Determination of radon activity concentration in drinking water and evaluation of the annual effective dose in Hassan district, Karnataka state, India

    International Nuclear Information System (INIS)

    Srinivasa, E.; Rangaswamy, D.R.; Sannappa, J.

    2015-01-01

    The radon concentration has been determined in 27 drinking water samples of Hassan district and was estimated by using emanometry technique and physicochemical parameters were estimated using standard techniques. The 222 Rn concentrations in water are varying from 0.85 ± 0.2 to 60.74 ± 2.5 Bq l -1 with an average value of 26.5 ± 1.65 Bq l -1 . This study reveals that 66 % of the drinking water samples have radon concentration level in excess of the EPA recommended maximum contamination level of 11.1 Bq l -1 . There is no significant correlation noted between radon concentration and physicochemical parameters. The mean annual effective ingestion doses received from all samples are lower than 0.1 mSv y -1 . (author)

  18. Calendar Year 2007 Program Benefits for U.S. EPA Energy Star Labeled Products: Expanded Methodology

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Marla; Homan, Gregory; Lai, Judy; Brown, Richard

    2009-09-24

    This report provides a top-level summary of national savings achieved by the Energy Star voluntary product labeling program. To best quantify and analyze savings for all products, we developed a bottom-up product-based model. Each Energy Star product type is characterized by product-specific inputs that result in a product savings estimate. Our results show that through 2007, U.S. EPA Energy Star labeled products saved 5.5 Quads of primary energy and avoided 100 MtC of emissions. Although Energy Star-labeled products encompass over forty product types, only five of those product types accounted for 65percent of all Energy Star carbon reductions achieved to date, including (listed in order of savings magnitude)monitors, printers, residential light fixtures, televisions, and furnaces. The forecast shows that U.S. EPA?s program is expected to save 12.2 Quads of primary energy and avoid 215 MtC of emissions over the period of 2008?2015.

  19. 40 CFR 195.20 - Fee payments.

    Science.gov (United States)

    2010-07-01

    ... AGENCY” and sent to: U.S. EPA, Washington Financial Management Center, Radon Proficiency Program User... or individuals who wish to notify EPA of any errors or corrections they wish to make to their listing...

  20. EPA's Information Architecture and Web Taxonomy

    Science.gov (United States)

    EPA's Information Architecture creates a topical organization of our website, instead of an ownership-based organization. The EPA Web Taxonomy allows audiences easy access to relevant information from EPA programs, by using a common vocabulary.

  1. Wind direction correlated measurements of radon and radon progeny in atmosphere: a method for radon source identification

    International Nuclear Information System (INIS)

    Akber, R.A.; Pfitzner, J.; Johnston, A.

    1994-01-01

    This paper describes the basic principles and methodology of a wind direction correlated measurement technique which is used to distinguish the mine-related and background components of radon and radon progeny concentrations in the vicinity of the ERA Ranger Uranium Mine. Simultaneous measurements of atmospheric radon and radon progeny concentrations and wind speed and direction were conducted using automatic sampling stations. The data were recorded as a time series of half hourly averages and grouped into sixteen 22.5 degrees wind sectors. The sampling interval and the wind sector width were chosen considering wind direction variability (σ θ ) over the sampling time interval. The data were then analysed for radon and radon progeny concentrations in each wind sector. Information about the wind frequency wind speed seasonal and diurnal variations in wind direction and radon concentrations was required for proper data analysis and interpretation of results. A comparison with model-based estimates for an identical time period shows agreement within about a factor of two between the two methods. 15 refs., 1 tab., 5 figs

  2. Instruments to measure radon activity concentration or exposure to radon. Interlaboratory comparison 2011

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2011-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by BfS. A radon measuring service is recognized by the competent authority if it proves its organizational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the website www.bfs.de/de/ion/radon/fachinfomessung/vergleichspruefungen.html and from the European Information System on Proficiency Testing Schemes (eptis) available in the internet. (orig.)

  3. Radon programme: presence and future

    International Nuclear Information System (INIS)

    Hulka, J.

    2009-01-01

    In this presentation an overview of radon programme experiences is presented. The paper summarises national radon policy, national programmes, legislation, the role of preventive measures and interventions with respect to existing and future exposure and knowledge of radon risk, problems of remediation strategies, practical protection in dwellings, radon measurements strategies, progress in radon measurement of an individual house (radon diagnosis), radon mapping process and sense of delineation of radon prone areas, natural radioactivity of building materials and radioactivity in public water and their role in the radon programme, public awareness on radon issue and publicity campaign. Some research activities are proposed aiming at effective solutions of radon issues in future

  4. The heightened activity of radon in water analysis from Lounovice area, Czech Republic

    International Nuclear Information System (INIS)

    Thinova, L.; Berka, Z.; Fridrichova, L.; Kaderova, J.; Cernohorska, E.; Pokorna, T.; Kosar, V.; Patak, M.; Kracmarova, I.

    2004-01-01

    The Lounovice area is located approximately 20 km south-east of Prague. Radon activity in fresh water from drilled-wells, used for village water supply, ranges between 700 and 900 Bq/l, which exceeds the standard for drinkable water by a factor higher than 100. Therefore, water is treated by aeration before use. Some residents, however, use drinking water from their own wells. A comprehensive radon and natural radioactivity survey was therefore conducted in this area. Secondary school students were engaged in this survey within the 'Physics Week' scientific program for young physicists, run by the Czech Technical University in Prague every year. in year 2004. The program included the following items: Laboratory gamma spectrometric measurement of the bedrock; Radon activity measurement in water before and after the aeration process; Radon monitoring at workplaces of the water company (the values provided by ionization chamber instruments and semiconductor detector instruments were compared); Radon daughters measurement at workplaces of the water company; In situ gamma spectrometry; In situ effective dose rate measurement; and Determination of a 'radon index' in the neighborhood of a drilled well

  5. Radon

    International Nuclear Information System (INIS)

    1990-01-01

    This leaflet in the At-a-Glance Series, describes what radon is, where it is found, why it presents a risk to health, the official advice, and the remedies that are available to reduce radon levels. (author)

  6. The Montana Radon Study: Social Marketing via Digital Signage Technology for Reaching Families in the Waiting Room

    Science.gov (United States)

    2015-01-01

    Objectives. I tested a social marketing intervention delivered in health department waiting rooms via digital signage technology for increasing radon program participation among priority groups. Methods. I conducted a tri-county, community-based study over a 3-year period (2010–2013) in a high-radon state by using a quasi-experimental design. We collected survey data for eligible participants at the time of radon test kit purchase. Results. Radon program participation increased at the intervention site (t38 = 3.74; P = .001; 95% confidence interval [CI] = 4.8, 16.0) with an increase in renters (χ21,228 = 4.3; P = .039), Special Supplementary Nutrition Program for Women, Infants, and Children families (χ21,166 = 3.13; P = .077) and first-time testers (χ21,228 = 10.93; P = .001). Approximately one third (30.3%; n = 30) attributed participation in the radon program to viewing the intervention message. The intervention crossover was also successful with increased monthly kit sales (t37 = 2.69; P = .01; 95% CI = 1.20, 8.47) and increased households participating (t23 = 4.76; P marketing message was an effective population-based intervention for increasing radon program participation. The results prompted policy changes for Montana radon programming and adoption of digital signage technology by 2 health departments. PMID:25121816

  7. Radon: A health problem and a communication problem

    International Nuclear Information System (INIS)

    Johnson, R.H.

    1992-01-01

    The US Environmental Protection Agency (USEPA) is making great efforts to alert the American public to the potential health risks of radon in homes. The news media have widely publicized radon as a problem; state and local governments are responding to public alarms; and hundreds of radon open-quotes expertsclose quotes are now offering radon detection and mitigation services. Apparently, USEPA's communication program is working, and the public is becoming increasingly concerned with radon. But are they concerned with radon as a open-quotes healthclose quotes problem in the way USEPA intended? The answer is yes, partly. More and more, however, the concerns are about home resale values. Many homebuyers are now deciding whether to buy on the basis of a single radon screening measurement, comparing it with USEPA's action guide of 4 pCi L -1 . They often conclude that 3.9 is OK, but 4.1 is not. Here is where the communication problems begin. The public largely misunderstands the significance of USEPA's guidelines and the meaning of screening measurements. Seldom does anyone inquire about the quality of the measurements, or the results of USEPA performance testing? Who asks about the uncertainty of lifetime exposure assessments based on a 1-hour, 1-day, 3-day, or even 30-day measurement? Who asks about the uncertainty of USEPA's risk estimates? Fortunately, an increasing number of radiation protection professions are asking such questions. They find that USEPA's risk projections are based on many assumptions which warrant further evaluation, particularly with regard to the combined risks of radon and cigarette-smoking. This is the next communication problem. What are these radiation professions doing to understand the bases for radon health-risk projections? Who is willing to communicate a balanced perspective to the public? Who is willing to communicate the uncertainty and conservatism in radon measurements and risk estimates?

  8. Radon in soil gas: distributions and correlations with the lithologies and pedologies of RMBH - Metropolitan region of Belo Horizonte - Minas Gerais - Brazil

    International Nuclear Information System (INIS)

    Lara, Evelise G.; Santos, Talita de O.; Oliveira, Arno Heeren de

    2013-01-01

    The concentration of radon in the soil gas is an important indicator to predict the radon geologic potential, usually indicated by Geological Radon Potential - GEORP, which is defined as the percent number of dwellings with indoor air radon concentration above the U.S.EPA action limit. The objective of this work was to investigate the distribution of radon concentration in soil gas and its relation with the pedologies and lithologies in the RMBH. The radon concentrations in soil gas were determined by using an AlphaGUARD monitor at 150 measurement points over the lithologies and pedologies of the area. The concentrations 226 Ra were determined by gamma spectrometry (HPGe) and U and Th by ICP-MS. The permeabilities of the soil were determined by using the RADON-JOK permeameter. Regarding pedologies, the perferric Red Latosols had the highest concentrations, with arithmetic mean to 60.6 ± 8.7 kBq.m -3 . Regarding lithologies, areas where the bedrocks are predominantly schists and metagraywackes showed the highest radon concentrations, with arithmetic mean to 46.5 ± 9.9 kBq.m -3 . The areas of lithology or pedology, in which the average radon concentrations are the highest also exhibit higher GEORP, e.g. for the perferric Red Latosol pedology shows GEORP of 26,5%. In this pedology, over 50% of the measurement points shows radon concentrations above of 50.0 kBq.m -3 , that, by the 'Swedish Criteria' classifies the area as high radon risk. The correlation with GEORP is even more significant when the radon concentration in soil gas is combined with soil permeability, through the Soil Radon Index indicator. (author)

  9. Radon in soil gas: distributions and correlations with the lithologies and pedologies of RMBH - Metropolitan region of Belo Horizonte - Minas Gerais - Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Lara, Evelise G.; Santos, Talita de O.; Oliveira, Arno Heeren de, E-mail: evelise.lara@gmail.com, E-mail: talitaolsantos@yahoo.com.br, E-mail: heeren@nuclear.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, M.G (Brazil). Dept. de Engenharia Nuclear; Rocha, Zildete; Palmieri, Helena E. Leonhardt; Brito, Walter de; Araujo, Gabriela Bastos D. de, E-mail: rochaz@cdtn.br, E-mail: help@cdtn.br, E-mail: britow@cdtn.br, E-mail: gabibastosdias@hotmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    The concentration of radon in the soil gas is an important indicator to predict the radon geologic potential, usually indicated by Geological Radon Potential - GEORP, which is defined as the percent number of dwellings with indoor air radon concentration above the U.S.EPA action limit. The objective of this work was to investigate the distribution of radon concentration in soil gas and its relation with the pedologies and lithologies in the RMBH. The radon concentrations in soil gas were determined by using an AlphaGUARD monitor at 150 measurement points over the lithologies and pedologies of the area. The concentrations {sup 226}Ra were determined by gamma spectrometry (HPGe) and U and Th by ICP-MS. The permeabilities of the soil were determined by using the RADON-JOK permeameter. Regarding pedologies, the perferric Red Latosols had the highest concentrations, with arithmetic mean to 60.6 ± 8.7 kBq.m{sup -3}. Regarding lithologies, areas where the bedrocks are predominantly schists and metagraywackes showed the highest radon concentrations, with arithmetic mean to 46.5 ± 9.9 kBq.m{sup -3}. The areas of lithology or pedology, in which the average radon concentrations are the highest also exhibit higher GEORP, e.g. for the perferric Red Latosol pedology shows GEORP of 26,5%. In this pedology, over 50% of the measurement points shows radon concentrations above of 50.0 kBq.m{sup -3}, that, by the 'Swedish Criteria' classifies the area as high radon risk. The correlation with GEORP is even more significant when the radon concentration in soil gas is combined with soil permeability, through the Soil Radon Index indicator. (author)

  10. Radon emanation from soils

    International Nuclear Information System (INIS)

    Markkanen, M.; Arvela, H.

    1992-01-01

    The results of gamma spectrometric sample measurements of radon ( 222 Rn) emanation coefficients and radium concentrations ( 226 Ra) from about 800 Finnish soil samples are presented. The radon emanation rate was measured in about 400 soil samples, using radon-tight cans and Lucas cells. The effects of water content and temperature on radon emanation were investigated, using various samples of different soil types. Radon emanation and the effect of water content on radon emanation were investigated separately for different grain sizes (samples of till). The results provide some information on radon emanation in different soil types and relate emanation in laboratory conditions to conditions in ground soil. In routine measurements of radon emanation from soil samples, use of a 5% water content was considered advisable. The correction coefficients of radon emanation varied between 0.3 and 1.5, depending on the water content and soil type. At 5% water content, hardly any difference was found between radon emanation at temperatures of 20 and 1 o C. Radon emanation was found to be an inverse function of grain sizes larger than 0.5 mm in diameter. (author)

  11. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    Energy Technology Data Exchange (ETDEWEB)

    Baumgartner, A. [Vienna Univ. of Technology, Atominstitut, Wien (Austria); Maringer, F.J.; Michai, P.; Kreuziger, M. [BEV-Federal Office of Metrology and Surveying, Wien (Austria)

    2006-07-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  12. US EPA Region 4 RMP Facilities

    Science.gov (United States)

    To improve public health and the environment, the United States Environmental Protection Agency (USEPA) collects information about facilities, sites, or places subject to environmental regulation or of environmental interest. Through the Geospatial Data Download Service, the public is now able to download the EPA Geodata shapefile containing facility and site information from EPA's national program systems. The file is Internet accessible from the Envirofacts Web site (http://www.epa.gov/enviro). The data may be used with geospatial mapping applications. (Note: The shapefile omits facilities without latitude/longitude coordinates.) The EPA Geospatial Data contains the name, location (latitude/longitude), and EPA program information about specific facilities and sites. In addition, the file contains a Uniform Resource Locator (URL), which allows mapping applications to present an option to users to access additional EPA data resources on a specific facility or site.

  13. Radon in geological medium

    Energy Technology Data Exchange (ETDEWEB)

    Hricko, J [GEOCOMPLEX, a.s., Bratislava (Slovakia)

    1996-12-31

    The paper presented deals with behavior of the radon in geological medium and with some results of the radon survey in Bratislava and Kosice regions. 1) The a{sub v} has been detected in the holes 0.80 m deep. The density of observations - 3 reference areas (one represents 20 stations) per 1 km{sup 2}. The radon risk maps in 1:25000 and 1:50000 scales have been compiled. The 56.8% of the project area lies in low radon risk, 37.6% in medium radon risk and 5.6% in high radon risk. Follow-up monitoring of the equivalent volume radon activity (EVRA) at the flats, located in the areas with high radon risk of the surface layer, has showed values several times higher than Slovak limits (Marianka, Raca, Vajnory). The evidence that neotectonic is excellent medium for rising up emanation to the subsurface layer, is shown on the map. The tectonic zone of Liscie udolie in Bratislava-Karlova Ves area has been clearly detected by profile radon survey (a{sub v} > 50 kBq/m{sup 3}). 2) At present, northern half of the area of Kosice in question was covered by radon survey. The low and medium radon risks have been observed here, while localities with high radon risk are small in extent. The part of radon risk and soil permeability map from northern Kosice area is shown. (J.K.) 3 figs., 2 refs.

  14. Radon in geological medium

    International Nuclear Information System (INIS)

    Hricko, J.

    1995-01-01

    The paper presented deals with behavior of the radon in geological medium and with some results of the radon survey in Bratislava and Kosice regions. 1) The a v has been detected in the holes 0.80 m deep. The density of observations - 3 reference areas (one represents 20 stations) per 1 km 2 . The radon risk maps in 1:25000 and 1:50000 scales have been compiled. The 56.8% of the project area lies in low radon risk, 37.6% in medium radon risk and 5.6% in high radon risk. Follow-up monitoring of the equivalent volume radon activity (EVRA) at the flats, located in the areas with high radon risk of the surface layer, has showed values several times higher than Slovak limits (Marianka, Raca, Vajnory). The evidence that neotectonic is excellent medium for rising up emanation to the subsurface layer, is shown on the map. The tectonic zone of Liscie udolie in Bratislava-Karlova Ves area has been clearly detected by profile radon survey (a v > 50 kBq/m 3 ). 2) At present, northern half of the area of Kosice in question was covered by radon survey. The low and medium radon risks have been observed here, while localities with high radon risk are small in extent. The part of radon risk and soil permeability map from northern Kosice area is shown. (J.K.) 3 figs., 2 refs

  15. Radiation exposure due to radon and radon daughters

    International Nuclear Information System (INIS)

    Ullmann, W.

    1976-01-01

    Underground miners working over long periods of time in mines with a high content of radon and radon daughters belong to that group of occupationally exposed persons who are subject to the greatest somatic risk, with values especially high if the permissible dose limits are exceeded. Follwing an overview of the permissible limits currently in use for radon and radon daughters as well as the results of examinations performed in nationally-owned underground mining of the G.D.R., considerations are presented on the measuring quantities requisite for statistical, control and safety measurements in this field. Finally, conclusions are drawn concerning the measuring procedures and instruments to be employed for practical work. (author)

  16. BGS Radon Protective Measures GIS

    International Nuclear Information System (INIS)

    Appleton, D.; Adlam, K.

    2000-01-01

    The British Geological Survey Radon Protective Measures Geographical Information System is described. The following issues are highlighted: Identification of development sites where radon protection is required in new dwellings; Mapping radon potential on the basis of house radon and geology; Radon Protective Measures GIS; Radon site reports; and Follow-up radon protective measures sire reports

  17. Shortening the Miles to the Milestones: Connecting EPA-Based Evaluations to ACGME Milestone Reports for Internal Medicine Residency Programs.

    Science.gov (United States)

    Choe, John H; Knight, Christopher L; Stiling, Rebekah; Corning, Kelli; Lock, Keli; Steinberg, Kenneth P

    2016-07-01

    The Next Accreditation System requires internal medicine training programs to provide the Accreditation Council for Graduate Medical Education (ACGME) with semiannual information about each resident's progress in 22 subcompetency domains. Evaluation of resident "trustworthiness" in performing entrustable professional activities (EPAs) may offer a more tangible assessment construct than evaluations based on expectations of usual progression toward competence. However, translating results from EPA-based evaluations into ACGME milestone progress reports has proven to be challenging because the constructs that underlay these two systems differ.The authors describe a process to bridge the gap between rotation-specific EPA-based evaluations and ACGME milestone reporting. Developed at the University of Washington in 2012 and 2013, this method involves mapping EPA-based evaluation responses to "milestone elements," the narrative descriptions within the columns of each of the 22 internal medicine subcompetencies. As faculty members complete EPA-based evaluations, the mapped milestone elements are automatically marked as "confirmed." Programs can maintain a database that tallies the number of times each milestone element is confirmed for a resident; these data can be used to produce graphical displays of resident progress along the internal medicine milestones.Using this count of milestone elements allows programs to bridge the gap between faculty assessments of residents based on rotation-specific observed activities and semiannual ACGME reports based on the internal medicine milestones. Although potentially useful for all programs, this method is especially beneficial to large programs where clinical competency committee members may not have the opportunity for direct observation of all residents.

  18. Integral measurement system for radon

    International Nuclear Information System (INIS)

    Garcia H, J.M.; Pena E, R.

    1996-01-01

    The Integral measurement system for Radon is an equipment to detect, counting and storage data of alpha particles produced by Radon 222 which is emanated through the terrestrial peel surface. This equipment was designed in the Special Designs Department of the National Institute of Nuclear Research. It supplies information about the behavior at long time (41 days) on each type of alpha radiation that is present into the environment as well as into the terrestrial peel. The program is formed by an User program, where it is possible to determine the operation parameters of a portable probe that contains, a semiconductor detector, a microprocessor as a control central unit, a real time clock and calendar to determine the occurred events chronology, a non-volatile memory device for storage the acquired data and an interface to establish the serial communications with other personal computers. (Author)

  19. Occurrence of radon in the Polish underground tourist routes

    Directory of Open Access Journals (Sweden)

    Jerzy Olszewski

    2015-08-01

    Full Text Available Background: There are about 200 underground tourist routes in Poland. There are caves, mines or underground structures. This paper presents the results of the research intended to identify the extent of the occurrence of radon concentrations in underground areas of tourist routes. Material and Methods: We conducted the measurement of periodic concentrations of radon (1–2 months in the summer using type Tastrak trace detectors. We determined the average concentrations of radon in air in 66 underground tourist routes in Poland. Results: The research results comprise 259 determinations of average radon concentrations in 66 routes. The arithmetic average of the results was 1610 Bqm–3, and the maximum measured concentration was over 20 000 Bqm–3. The minimum concentration was 100 Bqm–3 (threshold method considering the arithmetic average of the measurements. It was found that in 67% of the routes, the average concentration of radon has exceeded 300 Bqm–3 and in 22 underground routes it exceeded 1000 Bqm–3. Conclusions: Radon which occurs in many Polish underground tourist routes may be an organizational, legal and health problem. It is necessary to develop a program of measures to reduce radon concentrations in underground routes, especially routes located in the former mines. Med Pr 2015;66(4:557–563

  20. Radon testing in schools in New York State: a 20-year summary

    International Nuclear Information System (INIS)

    Kitto, Michael

    2014-01-01

    For nearly 20 years the Department of Health has conducted programs to assist in the measurement and reduction of indoor radon concentrations in 186 schools located primarily in Zone 1 areas of New York State. Although many schools had few or no rooms containing radon above 148 Bq/m 3 , some rooms had >740 Bq/m 3 and remediation techniques were utilized to reduce exposure. Short-term radon measurements in the schools showed little correlation to basement and first-floor radon results from single-family homes in the towns. - Highlights: • Relatively few schools in New York State have been tested for indoor radon. • We provide a summary of radon-testing results for measured schools. • The radon potential in schools is often less than in local houses. • Short-term measurement results exceeded their long-term counterparts in nearly every case

  1. Radon and cancer

    International Nuclear Information System (INIS)

    2011-01-01

    This publication proposes an overview on what is known about the carcinogenic effect of radon. It recalls the origin of radon, its presence in the environment, and its radioactivity. It comments data on the relationship between exposure to radon and lung cancer, and with other forms of cancer. It discusses the role of the exposure level, and the cases of professional and domestic exposure with respect to these risks. It indicates the hazardous areas in France which are well identified, outlines that smokers are more likely victims of risks related to radon, that this risk is still underrated and underestimated (notably by the public). It gives an overview of existing regulations regarding exposure to radon, of public health policies and national plans concerning radon, and recalls some WHO recommendations

  2. Risk assessment and control management of radon in drinking water

    International Nuclear Information System (INIS)

    Mills, W.A.

    1990-01-01

    The role of risk assessment and risk management of radon in drinking water was reviewed. It is noted that risk assessments for the public health consequences of radon in drinking water require information on radon concentration in water, exposure pathways, and dose-response relationships. On the other hand, risk management involves assumptions of risk acceptance and the establishment of governmental policies in accord with society's acceptance of these assumptions. Although risk assessment for radon exposures can be reasonably qualitative, risk management is clearly judgmental. The following conclusions/recommendations were made. (1) The presence of radon in drinking water is estimated to have its greatest health impact on the 18% of the US population served by private wells. (2) Although no direct evidence exists associated radon in water with health problems, the diseases that are associated with radon in drinking water are stomach cancer from ingestion and lung cancer from inhalation of radon decay products released during household use of water. (3) Using a number of questionable assumptions, the total number of cancer deaths per year attributable to radon in water is estimated to be about 5,000 as a maximum value, with essentially all cases occurring in the population served by private wells. (4) Promulgating federal regulations to control radon levels in water under the Safe Drinking Water Act seems unwarranted, since private wells would not likely be regulated. (5) Government control programs should be limited to emphasizing an awareness of possible substantially higher than average levels of radon in water in certain geological areas. 12 refs., 4 tabs

  3. Energy deposition and radiation quality of radon and radon daughters. Final report

    International Nuclear Information System (INIS)

    Karam, L.R.; Caswell, R.S.

    1996-01-01

    This program was aimed at creating a quantitative physical description, at the micrometer and nanometer levels, of the physical interactions of the alpha particles from radon and its daughters with cells at risk in the bronchial epithelium. The authors calculated alpha-particle energy spectra incident upon the cells and also energy deposition spectra in micrometer- and nanometer-sized sites as a function of cell depth, site size, airway diameter, activities of 218 Po and 214 Po, and other parameters. These data are now being applied, using biophysical models of radiation effects, to predict cell killing, mutations, and cell transformation. The model predictions are then compared to experimental biophysical, biochemical, and biological information. These studies contribute to a detailed understanding of the mechanisms of the biological effectiveness of the radiations emitted by radon and its progeny

  4. Radon awareness in Ireland: a assessment of the effectiveness of radon road shows

    International Nuclear Information System (INIS)

    Synnott, H.

    2006-01-01

    Full text: In late 2004 the Radiological Protection Institute of Ireland (R.P.I.I.) initiated a series of radon road shows in areas designated as High Radon Areas 1 in the R.P.I.I. s national radon survey of homes. The main objective of these road shows was to provide information to a local audience on the risks of exposure to radon. These road shows target both employers and householders. Each road show has the same general format. A presentation and/or meeting with a major employer representative group within the area. The purpose is to make employers aware of the risks associated with exposure to radon in the workplace and to highlight their obligations under current Irish health and safety legislation regarding radon in the workplace. An information stand on radon manned by R.P.I.I. staff members in a local shopping centre or other similar area. This provides those concerned about radon with accessible information on radon exposure risks, how to measure radon and the steps a home owner could take to reduce radon concentrations where necessary. Where possible R.P.I.I. staff members visit one or more schools in the general area. A short presentation on radon was given to students and students were given an opportunity to asks questions Maximizing media exposure to publicize our visits is vital to the success of these visits. Each visit is preceded by a Press Release whose main aim is to brief local and national media on the radon issue so as to achieve maximum publicity mainly through radio and television coverage. In general the media are very interested in the whole radon area and R.P.I.I. staff members have given 57 radio and 10 television interviews to date since the commencement of this initiative. The four road shows carried out to date have been successful in encouraging householders to carry out radon measurements. Since the start of the road shows to the present, the R.P.I.I. has seen a 44% increase in the number of householders requesting radon

  5. Project Radon

    International Nuclear Information System (INIS)

    Ekholm, S.

    1988-01-01

    The project started in March 1987. The objective is to perform radon monitoring in 2000 dwellings occupied by people employed by State Power Board and to continue to contribute to the development of radon filters. The project participates in developing methods for radon measurement and decontamination and in adapting the methods to large scale application. About 400 so called radon trace measurements (coarse measurement) and about 10 action measurements (decontamination measurement) have been made so far. Experience shows that methods are fully applicable and that the decontamination measures recommended give perfectly satisfactory results. It is also established that most of the houses with high radon levels have poor ventilation Many of them suffer from moisture and mould problems. The work planned for 1988 and 1989 will in addition to measurements be directed towards improvement of the measuring methods. An activity catalogue will be prepared in cooperation with ventilation enterprises. (O.S.)

  6. A Radon Chamber without Radium Source for Detector Calibration and Radon Measurements

    International Nuclear Information System (INIS)

    Al-Azmi, D.; Karunakara, N.

    2008-01-01

    A radon chamber of volume 216 liters was designed and constructed for calibration of radon detectors and radon test measurements. The main feature of this chamber is that the active 226 Ra source, to generate the 222 Rn inside the chamber volume, is not required. Instead, 222 Rn from soil gas is utilized for this purpose. The supply of radon comes from the soil gas. Soil gas is drawn from the soil to fill the chamber with high radon concentration levels (∼ 80 kBq/m3). Desired radon concentration levels can be obtained by drawing the soil gas for different time durations and/or flow rate (author)

  7. Radon reduction in waterworks

    International Nuclear Information System (INIS)

    Raff, O.; Haberer, K.; Wilken, R.D.; Funk, H.; Stueber, J.; Wanitschek, J.; Akkermann-Kubillus, A.; Stauder, S.

    2000-01-01

    The removal of radon from water using water aeration is one of the most effective methods for reducing radon in waterworks. Therefore, this report describes investigations on packed tower columns and shallow aeration devices and a method for mathematical modelling of gas exchange processes for dimensioning packed tower columns for radon removal. Moreover, possibilities for removing radon using active carbon filtration under waterworks typical conditions and for reducing indoor radon levels in waterworks are discussed. Finally, conclusions on the necessity of radon removal in German waterworks are drawn. (orig.) [de

  8. Low-cost Radon Reduction Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Rose, William B. [Univ. of Illinois, Urbana-Champaign, IL (United States); Francisco, Paul W. [Univ. of Illinois, Urbana-Champaign, IL (United States); Merrin, Zachary [Univ. of Illinois, Urbana-Champaign, IL (United States)

    2015-09-01

    The U.S. Department of Energy's Building America research team Partnership for Advanced Residential Retrofits conducted a primary scoping study on the impact of air sealing between the foundation and the living space on radon transport reduction across the foundation and living space floor assembly. Fifteen homes in the Champaign, Illinois, area participated in the study. These homes were instrumented for hourly continuous radon measurements and simultaneous temperature and humidity measurements. Blower door and zone pressure diagnostics were conducted at each house. The treatments consisted of using air-sealing foams at the underside of the floor that separated the living space from the foundation and providing duct sealing on the ductwork that is situated in the foundation area. The hypothesis was that air sealing the floor system that separated the foundation from the living space should better isolate the living space from the foundation; this isolation should lead to less radon entering the living space from the foundation. If the hypothesis had been proven, retrofit energy-efficiency programs may have chosen to adopt these isolation methods for enhanced radon protection to the living space.

  9. Notification: Fiscal Year 2015 Risk Assessment of EPA's Purchase Card and Convenience Check Programs

    Science.gov (United States)

    Project #OA-FY15-0064, August 26, 2015. The U.S. Environmental Protection Agency (EPA) Office oflnspector General (OIG) plans to begin the preliminary research phase ofauditing the agency's purchase card and convenience check programs.

  10. Reasons for increasing radon concentrations in radon remediated houses

    International Nuclear Information System (INIS)

    Clavensjoe, B.

    1997-01-01

    The study comprises 31 single-dwelling houses where remedial actions were carried out in the 1980s. In all of them the radon concentrations have increased more than 30% according to recent control measurements. Radon sources are building material as well as the soil. The remedial actions dealt with ventilation systems, leakage through the basement floor, air cushions, sub-slab suction or radon wells according to the original problems. Causes for the increase varied: In many houses with soil radon problems, the installation of a normal mechanical ventilation system is not a good remedial action. In some houses on a ground with high permeability and high radon content in the soil air, the radon concentration may increase by the lowering of the indoor air pressure. In other houses the increase was a measurement effect, where sites/rooms were confused. Living related causes were identified in a number of cases, where fan speeds were reduced for energy conservation/noise reduction purposes or different use of windows airing had occurred. Extension of the dwelling space without changing the ventilation system caused the increase in one house. 23 refs

  11. Mortality and indoor radon daughter concentrations in 13 Canadian cities

    International Nuclear Information System (INIS)

    Letourneau, E.G.; Wigle, D.T.

    1980-01-01

    A study was carried out to determine if lung cancer and general mortality rates in 13 Canadian cities were significantly correlated with average indoor radon daughter concentrations. The radon daughter measurements were obtained from a study of 10,000 homes chosen in a statistically valid grab sample basis. Cancer deaths by year of death, sex, age, and cause were retrieved for each of the cities for the period 1957-1976. Age specific and age standardized mortality rates were calculated. The results showed no evidence of any substantial association between general or lung cancer mortality rates and indoor radon daughter concentrations. The limitations of this study and the feasibility of a common international program of epidemiology of radon daughter exposure are discussed. A proposal is made for the use of case control studies of lung cancer to assess the relative importance of smoking, occupational and domestic exposure to radon daughters

  12. Report: Ongoing Management Improvements and Further Evaluation Vital to EPA Stewardship and Voluntary Programs

    Science.gov (United States)

    Report #2005-P-00007, February 17, 2005. We asked stakeholders to define stewardship, list motivators and obstacles to participating in stewardship programs, and outline key roles for EPA to play to foster participating in environmental stewardship.

  13. Radon-daughter exposures in energy-efficient buildings

    International Nuclear Information System (INIS)

    Nero, A.V.; Berk, J.V.; Boegel, M.L.; Hollowell, C.D.; Ingersoll, J.G.; Nazaroff, W.W.

    1981-10-01

    A radon concentration of 1 pCi/1 (37 Bq/m 3 ) appears to lie in the range that is typical for air inside US residential buildings. Moreover, some US residences have concentrations higher than 1 pCi/1, sometimes by an order of magnitude, implying significant individual risk to occupants. For typical radon daughter equilibrium ratios, this concentration corresponds to a radon daughter exposure rate of 0.2 working level months (WLM) per year. This exposure rate may account for a significant lung cancer incidence if data on lung cancers per unit exposure in miners are applicable to such low exposures. Reductions in air exchange rates may rise the typical exposure rate and even increase it to unacceptable levels in some cases. Measures that reduce energy use by reducing natural infiltration or mechanical ventilation in new or retrofit buildings are therefore undergoing severe scrutiny. Lawrence Berkeley Laboratory has performed measurements in buildings specifically designed to use energy efficiently or utilize solar heating. In many of these buildings radon concentrations appear to arise primarily from soil underlying the buildings. Measures to control higher levels, e.g., by mechanical ventilation with heat recuperation, appear to be economical. However, to evaluate energy-saving programs adequately requires a much more comprehensive characterization of radon sources (for example, by geographical area) and a much fuller understanding of the dynamics of radon and its daughters indoors than now exist

  14. [Estimation of effective doses derived from radon in selected SPA centers that use geothermal waters based on the information of radon concentrations].

    Science.gov (United States)

    Walczak, Katarzyna; Zmyślony, Marek

    2013-01-01

    Geothermal waters contain, among other components, soluble radon gas. Alpha radioactive radon is a health hazard to humans, especially when it gets into the respiratory tract. SPA facilities that use geothermal water can be a source of an increased radiation dose to people who stay there. Based on the available literature concerning radon concentrations, we assessed exposure to radon among people - workers and visitors of Spa centers that use geothermal waters. Radon concentrations were analyzed in 17 geothermal centers: in Greece (3 centers), Iran (5), China (4) and India (5). Doses recived by people in the SPA were estimated using the formula that 1 hour exposure to 1 Bq/m3 of radon concentration and equilibrium factor F = 0.4 corresponds to an effective dose of 3.2 nSv. We have found that radon levels in SPAs are from a few to several times higher than those in confined spaces, where geothermal waters are not used (e.g., residential buildings). In 82% of the analyzed SPAs, workers may receive doses above 1 mSv/year. According to the relevant Polish regulations, people receiving doses higher than 1 mSv/year are included in category B of radiation exposure and require regular dosimetric monitoring. Doses received by SPA visitors are much lower because the time of their exposure to radon released from geothermal water is rather short. The analysis of radon concentration in SPA facilities shows that the radiological protection of people working with geothermal waters plays an important role. It seems reasonable to include SPA workers staying close to geotermal waters into a dosimetric monitoring program.

  15. Indoor radon measurements and radon prognosis for the province of Kymi, southeastern Finland

    International Nuclear Information System (INIS)

    Pennanen, M.; Maekelaeinen, I.; Voutilainen, A.

    1996-12-01

    The purpose of the regional radon prognosis is to classify areas with different levels of radon risk. The radon prognosis gives the percentages of future homes expected to have indoor radon concentrations exceeding the levels of 200 and 400 Bq/m 3 . It is assumed that no protection against the entry of radon is used in construction. In this study about 5900 indoor radon measurements made in single family houses, semi-detached houses and row houses were used. Data on the location, geology and construction of buildings were determined from maps and questionnaires. An empirical statistical model, the adjusted indoor radon measurements and geological data were used to assess the radon risk from soil and bedrock in different areas. The building sites of the province of Kymi were divided into thirteen sub-areas. The radon prognosis are calculated for the most radon-prone foundation types including 1) houses with a slab-on-grade and 2) houses with a basement or hillside houses with open stairwells between basement and first floor. The radon levels are generally greater in the western part of the area. The radon risk is highest in gravel-dominated esker areas in southwestern, western (in Pyhtaa, Kotka, Anjalankoski, litti, Valkeala) and central (Taipalsaari) parts of the area. The radon risk is also high in some bedrock and till areas, also in southwestern and western parts of the area. In these areas the level of 200 Bq/m 3 will be exceeded in 80 % of new houses. About half of the future houses in these areas will have indoor radon concentrations exceeding 400 Bq/m 3 . The radon risk is lowest in the eastern part of the province of Kymi in every soil type. In this area the level of 200 Bq/m 3 will be exceeded in 30 % of new houses. Below 10 % will exceed 400 Bq/m 3 . (orig.) (14 refs.)

  16. Instruments to measure radon-222 activity concentration or exposure to radon-222. Intercomparison 2014

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2014-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by the Bundesamt fuer Strahlenschutz (BfS). A radon measuring service is recognized by the competent authority if it proves its organisational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the European Information System on Proficiency Testing Schemes (EPTIS) and from the BfS websites.

  17. Radon in workplaces

    International Nuclear Information System (INIS)

    Reichelt, A.; Lehmann, K.-H.; Reineking, A.; Porstendoerfer, J.; Schwedt, J.; Streil, T.

    2000-01-01

    The radiological assessment of the results of radon measurements in dwellings is not automatically applicable to workplaces due to different forms of utilization, constructional conditions, time of exposure, heating and ventilation conditions, additional aerosol sources, aerosol parameters, chemical substances, etc. In order to investigate the peculiarities of the radon situation in workplaces located inside buildings compared with that in dwellings, long-time recordings of radon, attached radon progeny and unattached radon progeny concentrations ( 218 Po, 214 Pb, 214 Bi) are carried out at several categories of workplaces (e.g. offices, social establishments, schools, production rooms, workshops, kitchens, agricultural facilities). 36 workplaces have been investigated. There have been carried out at least 2-3 long-time recordings for each workplace during different seasons. At the same time the gamma dose rate, meteorological conditions, aerosol particle concentrations have been registered. Many special dates from the workplaces and the buildings have been recorded. Activity size distribution of the aerosol-attached and unattached fraction of short-lived radon decay products have been determinated in 20 workplaces. Mainly the following measurement systems were used: Radon- and Radon Progeny Monitor EQF 3020, SARAD GmbH, Germany. Alpha-Track Radon Detectors, BfS Berlin, Germany. Screen Diffusion Batteries with Different Screens, University of Goettingen, Germany. Low-Pressure Cascade Impactor, Type BERNER. Condensation Nuclei Counter, General Electric, USA. PAEC-f p -Rn-Monitor, University of Goettingen, Germany. Through the measurements, many peculiarities in the course of the radon-concentration, the equilibrium factor F, the unattached fraction f p and the activity size distribution have been determined. These amounts are influenced mainly by the working conditions and the working intervals. The influence of these peculiarities in workplaces on the dose have

  18. Public perceptions of radon risk

    International Nuclear Information System (INIS)

    Mainous, A.G. III; Hagen, M.D.

    1993-01-01

    Since 1984, a significant amount of media attention has focused on health threats from radon gas exposure. Using a probability telephone survey of adults (n = 685), we studied public perceptions of risk from radon exposure versus other environmental health risks. The results indicated that 92% of those individuals who had heard of radon believe radon to be a health risk, although only 4% believe they are currently exposed to high levels of radon gas. Perception of risk from radon was positively related to other perceptions of environmental risks. Younger and less educated individuals were more likely to perceive radon as a health risk. Women were three-and-one-half times as likely as men to perceive risk from radon. However, there was no significant relationship between perceived risk from radon and cigarette smoking. Media attention has apparently led to public awareness of radon hazards, but further attention is needed to improve smokers' awareness of their special risks from radon

  19. U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA) ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) PROGRAM: ARSENIC TREATMENT TECHNOLOGIES

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) Environmental Technology Verification (ETV) program evaluates the performance of innovative air, water, pollution prevention and monitoring technologies that have the potential to improve human health and the environment. This techn...

  20. Comparative study of radon concentration in selected modern and traditional building at Kenyatta University

    International Nuclear Information System (INIS)

    Chege, W.M.; Rathore, I.V.S.; Chhabra, S.C.; Mustapha, A.O.

    2010-01-01

    Radon is leading source of radiation exposure to the public and increases risk of cancer (UNSCEAR, 2000). There is general lack of data on indoor radon in Kenya especially on building design-traditional versus modern. In rural Kenya traditional mud huts coexist with modern stone building. Indoor radon found to vary widely in Kenya: Mustapha et al (2002): 5-1200 Bqm3, Maina et al (2004): 5-704 Bqm3. None of previous works indicates radon variation with building design. The aim of the current study is to compare radon concentrations in coexisting stone buildings and mud huts. Such data would be useful in formulation of policies regarding housing, as part of radon data base in Kenya Experimental Techniques Characteristic of selected buildings: Traditional Huts: Single roomed, Wall made of wood and plastered using mud, bare floor and no ceiling, grass-thatched or mud plastered, doors and windows remained open during the sampling period. Modern Buildings: (Classes used to represent modern building). Those made of natural stone, wooden floor, ceiling, doors and windows remained shut during the sampling period. Measurement of Radon Concentration Radon sampling was done using Charcoal canisters (EPA type). They were activated, and then exposed simultaneously at sampling sites for 48 hours. Analysis and data acquisition was done using NaI(Tl) gamma-ray spectrometer. Radon concentration was calculated based on gamma rays emitted by 214Pb (295 and 352 keV) and 214Bi (609 keV). 13 Results and Discussion Radon levels were higher in classrooms and significantly high in huts. Mean (Bqm-3 ) Minimum (Bqm-3 ) Maximum (Bqm-3 ). Traditional huts had 170.3 15.6 30.2 315.4 while modern buildings had 193 ±19.3 115.76 257.2. There were higher levels in classroom despite lower levels of 226Ra (50.18 Bqkg-1) in natural stone. Possible source of high concentrations: - radon seeping in through floor boards building up over time as building more closed up - Radon concentration was more varied

  1. Environmental radon

    International Nuclear Information System (INIS)

    Majumdar, S.K.; Schmalz, R.F.; Miller, E.W.

    1990-01-01

    This book covers many aspects of environmental radon, including: historical perspectives; occurrence and properties; detection, measurement, and mitigation, radon and health; and political, economic, and legislative impacts

  2. Radon discrimination for work place air samples

    International Nuclear Information System (INIS)

    Bratvold, T.

    1994-01-01

    Gross alpha/beta measurement systems are designed solely to identify an incident particle as either an alpha or a beta and register a count accordingly. The tool of choice for radon identification, via decay daughters, is an instrument capable of identifying the energy of incident alpha particles and storing that information separately from detected alpha emissions of different energy. In simpler terms, the desired instrument is an alpha spectroscopy system. K Basins Radiological Control (KBRC) procured an EG ampersand G ORTEC OCTETE PC alpha spectroscopy system to facilitate radon identification on work place air samples. The alpha spectrometer allows for the identification of any alpha emitting isotope based on characteristic alpha emission energies. With this new capability, KBRC will explicitly know whether or not there exists a true airborne concern. Based on historical air quality data, this new information venue will reduce the use of respirators substantially. Situations where an area remains ''on mask'' due solely to the presence of radon daughters on the grab air filter will finally be eliminated. This document serves to introduce a new method for radon daughter detection at the 183KE Health Physics Analytical Laboratory (HPAL). A new work place air sampling analysis program will be described throughout this paper. There is no new technology being introduced, nor any unproven analytical process. The program defined over the expanse of this document simply explains how K Basins Radiological Control will employ their alpha spectrometer

  3. Modelling of radon control and air cleaning requirements in underground uranium mines

    International Nuclear Information System (INIS)

    El Fawal, M.; Gadalla, A.

    2014-01-01

    As a part of a comprehensive study concerned with control workplace short-lived radon daughter concentration in underground uranium mines to safe levels, a computer program has been developed and verified, to calculate ventilation parameters e.g. local pressures, flow rates and radon daughter concentration levels. The computer program is composed of two parts, one part for mine ventilation and the other part for radon daughter levels calculations. This program has been validated in an actual case study to calculate radon concentration levels, pressure and flow rates required to maintain acceptable levels of radon concentrations in each point of the mine. The required fan static pressure and the approximate energy consumption were also estimated. The results of the calculations have been evaluated and compared with similar investigation. It was found that the calculated values are in good agreement with the corresponding values obtained using ''REDES'' standard ventilation modelling software. The developed computer model can be used as an available tool to help in the evaluation of ventilation systems proposed by mining authority, to assist the uranium mining industry in maintaining the health and safety of the workers underground while efficiently achieving economic production targets. It could be used also for regulatory inspection and radiation protection assessments of workers in the underground mining. Also with using this model, one can effectively design, assess and manage underground mine ventilation systems. Values of radon decay products concentration in units of working level, pressures drop and flow rates required to reach the acceptable radon concentration relative to the recommended levels, at different extraction points in the mine and fan static pressure could be estimated which are not available using other software. (author)

  4. Reaching out to multiple stake holders E.P.A.'s public outreach and communications program for the waste isolation pilot plant

    International Nuclear Information System (INIS)

    Ferguson, R.; Malina, C.

    2001-01-01

    In October 1992, Congress enacted the Waste Isolation Pilot Plant (WIPP) Land Withdrawal Act which gave the U.S. Environmental Protection Agency (EPA) significant new responsibilities for overseeing the U.S. Department of Energy's (DOE) activities at the WIPP. The WIPP, which is designed to safely contain radioactive waste for at least 10 000 years, is located near Carlsbad, New Mexico, and is the world's first geological disposal facility for transuranic waste. In May 1998, EPA determined that the WIPP will safely contain transuranic waste, which is generated as a result of the U.S. nuclear weapons program, because DOE demonstrated that the facility will comply with the Agency's radioactive waste disposal standards. EPAS's decision allowed the DOE to begin disposing radioactive waste in the WIPP. As of October 2000, the WIPP has received over 75 shipments of transuranic radioactive waste. In implementing its new responsibilities, EPA committed to conducting an open public process that includes interaction with all interested parties. EPA believes that a successful communications and consultation program facilitates the regulatory oversight process and promotes sound public policy decisions. As a first step in meeting its commitment to an open public process, EPA conducted a public consultation and communication 'needs assessment'. The purpose of this assessment was to obtain input from citizen and environmental groups and the public on their key concerns about EPA's role and responsibilities at the WIPP, as well as to determine the best methods for communicating with them. Throughout the WIPP certification process, EPA provided opportunities for public involvement beyond those required in typical U.S. regulatory programs. Doing this, we believe, increased the public's understanding of EPA's role and responsibilities with respect to the WIPP project, enabled the public to make informed decisions about the project by increasing their knowledge about radiation and it

  5. Radon thematic days - Conference proceedings

    International Nuclear Information System (INIS)

    2011-03-01

    This document brings together the available presentations given at the Radon thematic days organized by the French society of radiation protection (SFRP). Twenty five presentations (slides) are compiled in the document and deal with: 1 - General introduction about radon (Sebastien Baechler, IRA); 2 - Survey of epidemiological studies (Dominique Laurier, IRSN); 3 - Dosimetric model (Eric Blanchardon, Estelle Davesne, IRSN); 4 - Radon issue in Franche-Comte: measurement of the domestic exposure and evaluation of the associated health impact (Francois Clinard, InVS); 5 - WHO's (World Health Organization) viewpoint in limiting radon exposure in homes (Ferid Shannoun, OMS); 6 - Radon measurement techniques (Roselyne Ameon, IRSN); 7 - Quality of radon measurements (Francois Bochud, IRA); 8 - International recommendations (Jean-Francois Lecomte, IRSN); 9 - Radon management strategy in Switzerland - 1994-2014 (Christophe Murith, OFSP); 10 - 2011-2015 action plan for radon risk management (Jean-Luc Godet, Eric Dechaux, ASN); 11 - Radon at work place in Switzerland (Lisa Pedrazzi, SUVA); 12 - Strategies of radiation protection optimization in radon exposure situations (Cynthia Reaud, CEPN); 13 - Mapping of the radon potential of geologic formations in France (Geraldine Ielsch, IRSN); 14 - Radon database in Switzerland (Martha Gruson, OFSP); 15 - Radon 222 in taps water (Jeanne Loyen, IRSN); 16 - Buildings protection methods (Bernard Collignan, CSTB, Roselyne Ameon, IRSN); 17 - Preventive and sanitation measures in Switzerland (Claudio Valsangiacomo, SUPSI); 18 - Training and support approach for building specialists (Joelle Goyette-Pernot, Fribourg engineers and architects' school); 19 - Status of radon bulk activity measurements performed between 2005-2010 in public areas (Cyril Pineau, ASN); 20 - Neuchatel Canton experiments (Didier Racine, SENE); 21 - Montbeliard region experience in the radon risk management (Isabelle Netillard, Pays de Montbeliard Agglomeration); 22

  6. EPA Environmental Chemistry Laboratory

    Science.gov (United States)

    1993-01-01

    The Environmental Protection Agency's (EPA) Chemistry Laboratory (ECL) is a national program laboratory specializing in residue chemistry analysis under the jurisdiction of the EPA's Office of Pesticide Programs in Washington, D.C. At Stennis Space Center, the laboratory's work supports many federal anti-pollution laws. The laboratory analyzes environmental and human samples to determine the presence and amount of agricultural chemicals and related substances. Pictured, ECL chemists analyze environmental and human samples for the presence of pesticides and other pollutants.

  7. Distribution of radon concentration in residences and others buildings of Belo Horizonte city, MG, Brazil

    International Nuclear Information System (INIS)

    Santos, Talita de Oliveira

    2010-01-01

    Human beings are exposed to ionizing radiation from many natural sources. Radon and its progeny have been recognized as the most important contributors to the natural radioactivity dose, accounting for about half of all human exposure to ionizing radiation. Radon is a α-radioactive noble gas derived from the natural series of uranium and thorium, which occurs in a wide concentration range in all geological materials, especially, in rocks, soils and waters. By diffusion and convection, radon migrates from the rocks and soils to atmosphere and through fissures, pipes and holes it may enter the dwellings and other buildings. Another important radon source in dwellings is its emanation from the construction material. The radon progeny concentration in dwellings has been receiving considerable global attention due to its potential effect in causing lung cancer if it deposited in upper respiratory tract when inhaled. This work presents radon concentration distribution in dwellings in Metropolitan Region of Belo Horizonte - RMBH. The geological settings of the area are Archean rocks of Granitic Gneissic Complex and of metasediments sequences of the great Precambrian unit of the Iron Quadrangle of Minas Gerais, Brazil. Radon concentration measurements were carried out with continuous detector AlphaGUARD PQ200PRO (Genitron), in passive mode and with passive detectors E-PERM Electrets Ion Chamber-EIC. The radon progeny concentration was carried out with a solid state alpha spectroscope, the DOSEman PRO (Sarad). It was found an indoor radon concentration varying in a large range from 4 to 2664,0 Bq.m"-"3, with an average value of 108.0 Bq.m"-"3, median of 70 Bq.m"-"3, geometric mean equal to 76 Bq.m"-"3 and standard deviation of 170 Bq.m"-"3. About 15% of the results are over the United States Environmental Protection Agency (U.S. EPA) actions level, which is 148 Bq.m"-"3.The equilibrium factor between radon and its progeny were determined in dwellings, as 0.3 in average

  8. Radon-film-badges by solid radiators to complement track detector-based radon monitors

    International Nuclear Information System (INIS)

    Tommasino, L.; Tommasino, M.C.; Viola, P.

    2009-01-01

    Existing passive radon monitors, based on track detectors, present many shortcomings, such as a limited response sensitivity for one-week-indoor measurements and a limited response linearity for the assessment of large radon exposures indoors, in thermal spa, in caves, and in soil. Moreover, for in-soil measurements these monitors are too bulky and are often conducive to wrong results. For what concerns the radon-in-water measurements, they are just not suitable. A new generation of passive radon monitors is introduced in this paper, which are very similar to the compact badges used in neutron- and gamma-dosimetry and will be referred to as radon-film-badges. These film-badges are formed by thin-film radiators with suitable radon-sorption characteristics, facing track detectors. The key strategy adopted for these radiators is to exploit an equilibrium type of radon sorption in solids. Even though this new generation of passive monitors is at its infancy, it appears already clear that said monitors make it finally possible to overcome most of the shortcomings of existing passive radon monitors. These devices are uniquely simple and can be easily acquired by any existing radon service to complement their presently used passive radon monitors with little or no effort.

  9. Radon in buildings

    International Nuclear Information System (INIS)

    Connell, J.J.

    1991-01-01

    This guide is intended to inform designers, householders and other building owners about the radon problem and to help in deciding if there is need to take any action to reduce radon levels in their homes or other buildings.It explains what radon is, how it enters buildings and what effect it may have on health. Reference is made to some of the usual ways of reducing the level of radon and guidance is given on some sources of assistance

  10. An assessment of ecological and case-control methods for estimating lung cancer risk due to indoor radon

    International Nuclear Information System (INIS)

    Stidley, C.A.; Samet, J.M.

    1992-01-01

    Studies of underground miners indicate that indoor radon is an important cause of lung cancer. This finding has raised concern that exposure to radon also causes lung cancer in the general population. Epidemiological studies, including both case-control and ecological approaches, have directly addressed the risks of indoor residential radon; many more case-control studies are in progress. Ecological studies that associate lung-cancer rates with typical indoor radon levels in various geographic areas have not consistently shown positive associations. The results of purportedly negative ecological studies have been used as a basis for questioning the hazards of indoor radon exposure. Because of potentially serious methodologic flaws for testing hypotheses, we examined the ecological method as a tool for assessing lung-cancer risk from indoor radon exposure. We developed a simulation approach that utilizes the Environmental Protection Agency (EPA) radon survey data to assign exposures to individuals within counties. Using the computer-generated data, we compared risk estimates obtained by ecological regression methods with those obtained from other regression methods and with the open-quotes trueclose quotes risks used to generate the data. For many of these simulations, the ecological models, while fitting the summary data well, gave risk estimates that differed considerably from the true risks. For some models, the risk estimates were negatively correlated with exposure, although the assumed relationship was positive. Attempts to improve the ecological models by adding smoking variables, including interaction terms, did not always improve the estimates of risk, which are easily affected by model misspecification. Because exposure situations used in the simulations are realistic, our results show that ecological methods may not accurately estimate the lung-cancer risk associated with indoor radon exposure

  11. Radon and its hazards

    International Nuclear Information System (INIS)

    Chang Guilan

    2002-01-01

    The author describes basic physical and chemical properties of radon and the emanation, introduces methods of radon measurement, expounds the hazards of non-mine radon accumulation to the health of human being and the protection, as well as the history how the human being recognizes the hazards of radon through the specific data and examples, and finally proposes protecting measures to avoid the hazards of radon to the health of human being, and to do ecologic evaluation of environments

  12. Radon detection system, design, test and performance

    International Nuclear Information System (INIS)

    Balcazar, M.; Chavez, A.; Pina-Villalpando, G.; Navarrete, M.

    1999-01-01

    A portable radon detection system (α-Inin) has been designed and constructed for using it in adverse environmental conditions where humidity, temperature and chemical vaporous are present. The minimum integration time is in periods of 15 min during 41 days. A 12 V battery and a photovoltaic module allow the α-Inin autonomy in field measurements. Data is collected by means of a laptop computer where data processing and α-Inin programming are carried out. α-Inin performance was simultaneously tested in a controlled radon chamber, together with a commercial α-Meter

  13. Seasonal radon measurements in Darbandikhan Lake water resources at Kurdistan region-northeastern of Iraq

    Science.gov (United States)

    Jafir, Adeeb Omer; Ahmad, Ali Hassan; Saridan, Wan Muhamad

    2016-03-01

    A total of 164 water samples were collected from Darbandikhan Lake with their different resources (spring, stream, and lake) during the four seasons, and the measurements were carried out using the electronic RAD 7 detector. For spring water the average radon concentration for spring, summer, autumn and summer were found to be 8.21 Bq/1, 8.94 Bq/1, 7.422 Bq/1, and 8.06 Bq/1, respectively, while for lake and streams the average values were found to be 0.43 Bq/1, 0.877 Bq/1, 0.727 Bq/1, 0.575 Bq/1 respectively. The radon concentration level was higher in summer and lower in spring, and only two samples from spring water have radon concentrations more than 11.1 Bq/1 recommended by the EPA. Total annual effective dose due to ingestion and inhalation has been estimated, the mean annual effective dose during the whole year for spring water was 0.022 mSv/y while for lake with streams was 0.00157 mSv/y. The determined mean annual effective dose in water was lower than the 0.1 mSv/y recommended by WHO. Some physicochemical parameters were measured and no correlation was found between them and radon concentration except for the conductivity of the spring drinking water which reveals a strong correlation for the four seasons.

  14. Radon/radon-daughter measurement methods and instrumentation

    International Nuclear Information System (INIS)

    Rock, R.L.

    1977-01-01

    Radon-daughter measurement equipment and techniques have been continuously improved over the last 25 years. Improvements have been in the areas of accuracy, time and convenience. We now have miniaturized scalers and detectors available for measuring the alpha particle count rates from aerosol samples collected on filter papers. We also have small lightweight efficient pumps for conveniently collecting samples and we have various counting methods which allow us to choose between making very precise measurements or nominal measurements. Radon-daughter measurement methods used in uranium mines and mills are discussed including a personal radon-daughter-exposure integrating device which can be worn by miners

  15. Radon level and radon effective dose rate determination in Moroccan dwellings using SSNTDs

    International Nuclear Information System (INIS)

    Oufni, L.; Misdaq, M.A.; Amrane, M.

    2005-01-01

    Inhalation of radon ( 222 Rn) and its daughter product are a major source of natural radiation exposure. The measurement of radon activity in dwelling is assuming ever increasing importance. It is known from recent surveys in many countries that radon and its progeny contribute significantly to total inhalation dose and it is fairly established that radon when inhaled in large quantity causes lung disorder. Keeping this in view, the indoor radon activity level and radon effective dose rate were carried out in the dwellings of Beni-Mellal, Khouribgra and Ben Guerir cities, Morocco, using the solid state nuclear track detectors (SSNTD) technique. Assuming an indoor occupancy factor of 0.8 and 0.4 for the equilibrium factor of radon indoors, we found that the 222 Rn effective dose rate in the studied dwellings ranges from 1.01 to 7.90mSvy -1 . The radon activity in the corresponding dwellings was found to vary from 40 to 532Bqm -3 . The radon activity has not only been found to vary with seasonal changes, but also with the age, the construction mode of houses, the ventilation conditions and with specific sites and geological materials

  16. Update on radon-mitigation research in schools. Rept. for 1988-Aug 91

    International Nuclear Information System (INIS)

    Leovic, K.W.; Craig, A.B.; Harris, D.B.

    1991-01-01

    The paper is an overview of research by EPA's Air and Energy Engineering Research Laboratory (AEERL) on radon mitigation in 47 schools since 1988. The structural and heating, ventilating, and air-conditioning (HVAC) system characteristics of the research schools are presented, along with the mitigation techniques implemented in the schools. Research discussed includes recent and on-going projects in Colorado, Maine, Maryland, Ohio, South Dakota, Tennessee, and Virginia. Initial research focussed on the application of active subslab depressurization (ASD) to school buildings, and recent research has emphasized the ability and limitations of using HVAC systems to reduce radon levels in schools. A goal of future projects is to compare the effectiveness of the two techniques in the same building. Slab-on-grade is the most prevalent substructure in AEERL's research schools and, depending on pressure field extension, ASD systems have been recommended for radon control in many of them. In schools where they have been installed, ASD systems have performed well and are currently being evaluated for long-term performance. The distribution of HVAC system types in these schools is about a third central air handling systems, a third unit ventilators, and a third that do not supply conditioned outdoor air (i.e., fan coil units or radiant heat)

  17. Tribal Grant Program Area Polygons with Project Officer and Tribal Contact Information, US EPA Region 9, 2015, Regional Tribal Operations Committee

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains information pertaining to EPA Region 9 project officers and their areas of oversight, EPA Region 9 grant program recipients and grant types,...

  18. Radon therapy; Radon in der Therapie

    Energy Technology Data Exchange (ETDEWEB)

    Spruck, Kaija [Technische Hochschule Mittelhessen, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2017-04-01

    Radon therapies are used since more than 100 years in human medicine. Today this method is controversially discussed due to the possible increase of ionizing radiation induced tumor risk. Although the exact mode of biological radiation effect on the cell level is still not known new studies show the efficiency of the radon therapy without side effect for instance for rheumatic/inflammatory or respiratory disorders.

  19. Estimation of effective doses derived from radon in selected SPA centers that use geothermal waters based on the information of radon concentrations

    Directory of Open Access Journals (Sweden)

    Katarzyna Walczak

    2013-04-01

    Full Text Available Background: Geothermal waters contain, among other components, soluble radon gas. Alpha radioactive radon is a health hazard to humans, especially when it gets into the respiratory tract. SPA facilities that use geothermal water can be a source of an increased radiation dose to people who stay there. Based on the available literature concerning radon concentrations, we assessed exposure to radon among people - workers and visitors of Spa centers that use geothermal waters. Material and Methods: Radon concentrations were analyzed in 17 geothermal centers: in Greece (3 centers, Iran (5, China (4 and India (5. Doses recived by people in the SPA were estimated using the formula that 1 hour exposure to 1 Bq/m3 of radon concentration and equilibrium factor F = 0.4 corresponds to an effective dose of 3.2 nSv. Results: We have found that radon levels in SPAs are from a few to several times higher than those in confined spaces, where geothermal waters are not used (e.g., residential buildings. In 82% of the analyzed SPAs, workers may receive doses above 1 mSv/year. According to the relevant Polish regulations, people receiving doses higher than 1 mSv/year are included in category B of radiation exposure and require regular dosimetric monitoring. Doses received by SPA visitors are much lower because the time of their exposure to radon released from geothermal water is rather short. Conclusions: The analysis of radon concentration in SPA facilities shows that the radiological protection of people working with geothermal waters plays an important role. It seems reasonable to include SPA workers staying close to geotermal waters into a dosimetric monitoring program. Med Pr 2013;64(2:193–198

  20. The April 1994 and October 1994 radon intercomparisons at EML

    International Nuclear Information System (INIS)

    Fisenne, I.M.; George, A.C.; Perry, P.M.; Keller, H.W.

    1995-10-01

    Quality assurance/quality control (QA/QC) are the backbone of many commercial and research processes and programs. QA/QC research tests the state of a functioning system, be it the production of manufactured goods or the ability to make accurate and precise measurements. The quality of the radon measurements in the US have been tested under controlled conditions in semi-annual radon gas intercomparison exercises sponsored by the Environmental Measurements Laboratory (EML) since 1981. The two Calendar Year 1994 radon gas intercomparison exercises were conducted in the EML exposure chamber. Thirty-two groups including US Federal facilities, USDOE contractors, national and state laboratories, universities and foreign institutions participated in these exercises. The majority of the participant's results were within ±10% of the EML value at radon concentrations of 570 and 945 Bq m -3

  1. Radon atlas of Finland

    International Nuclear Information System (INIS)

    Voutilainen, A.; Maekelaeinen, I.; Pennanen, M.; Reisbacka, H.; Castren, O.

    1997-11-01

    The most efficient means of reducing indoor radon exposure is to locate and mitigate dwellings with radon concentration exceeding the action level of 400 Bq/m 3 and to build new houses so that radon concentrations do not exceed 200 Bq/m 3 . The maps and tables in this report are useful tools for those who plan and decide what kind of radon mitigation measures are needed in municipalities. STUK (The Radiation and Nuclear Safety Authority) has an indoor radon database of 52 000 dwellings, for which the indoor radon concentration and construction details are known. The building site soil type of about 38 000 dwellings is known. This atlas is a summary of all indoor radon measurements made by STUK in lowrise dwellings and in first-floor flats. The results are shown as arithmetic means of 5- or 10-km squares on maps of the provinces. Three radon maps have been made for each province. On one map the data consist of all measurements the position coordinates of which are known. On the two other maps the building sites of houses are classified into permeable and low-permeable soil types. The tables show statistics for all indoor radon measurements by municipality and building site soil type. (orig.)

  2. Scopingreport radon

    International Nuclear Information System (INIS)

    Blaauboer, R.O.; Vaas, L.H.; Hesse, J.M.; Slooff, W.

    1989-09-01

    This report contains general information on radon concerning the existing standards, sources and emissions, the exposure levels and effect levels. lt serves as a basis for the discussion during the exploratory melting to be held in November/December 1989, aimed at determining the contents of the Integrated Criteria Document Radon. Attention is focussd on Rn-222 (radon) and Rn-220 (thoron), presently of public interest because of radon gas pollution in private homes. In the Netherlands air quality standards nor product standards for the exhalation rate of building materials have been recommended. The major source of radon in the Netherlands is the soil gas (> 97%), minor sources are phosphate residues and building materials (> 2% in total). Hence, the major concern is the transfer through the inhalation of air, the lung being the most critical organ at risk to develop cancer. Compared to risks for humans, the risks of radon and its daughters for aquatic and terrestric organisms, as well as for agricultural crops and livestock, are assumed to be limited. In the Netherlands the average dose for man due to radon and thoron progeny is appr. 1.2 mSv per year, the estimated dose range being 0.1-3.5 mSv per year. This dose contributes for about 50% to rhe total exposure due to all sources of ionizing radiation. Of this dose respectively 80% is caused by radon and about 90% is received indoor. The estimated dose for the general population corresponds to a risk for inducing fatal cancers of about 15 x 10-6 per year, ranging from 1.2 x 10-6 to 44 x 10-6 which exceeds the risk limit of 1 x 10-6 per year -as defined in the standardization policy in the Netherlands for a single source of ionizing radiation-with a factor 15 (1- 44). Reduction of exposure is only possible in the indoor environment. Several techniques have been described to reduce the indoor dose, resulting from exhalation of the soil and building materials. )aut- hor). 37 refs.; 3 figs.; 8 tabs

  3. The effect of natural ventilation on radon and radon progeny levels in houses

    International Nuclear Information System (INIS)

    Cavallo, A.; Gadsby, K.; Reddy, T.A.; Socolow, R.

    1992-01-01

    In contradiction to the widely held assumption that ventilation is ineffective as a means of reducing indoor radon concentrations, experiments in a research house have shown that the basement radon level can be reduced by a factor of 5-10 using only natural ventilation. Measurements of the outdoor-basement pressure differential and the radon entry rate show that this unexpectedly large reduction in indoor radon levels is caused by two complementary physical processes. The first mechanism is the obvious one: dilution. Radon concentrations are lowered by the addition of uncontaminated outdoor air. The second mechanism is less evident: an open basement window reduces basement depressurisation. This decreases the rate at which radon-laden soil gas is drawn into the house. It was also found that the radon entry rate is a linear function of basement depressurisation up to a differential pressure of about 4 Pa, as would be expected for laminar soil gas flow; opening two basement windows approximately doubles the building air exchange rate and reduces the radon entry rate by up to a factor of 5. (author)

  4. Radon og boligen

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    Radon er en radioaktiv og sundhedsskadelig luftart, som ved indånding øger risikoen for lungekræft. Der er ingen dokumenteret nedre grænse for, hvornår radon er ufarligt. Derfor anbefales det, at man tilstræber et så lavt radonindhold i indeluften som muligt. Man kan hverken lugte, se, høre eller...... smage radon, så vil du vide, om du har radon i din bolig, må du måle radonindholdet i indeluften. Radon forekommer naturligt i jorden og kan suges ind sammen med jordluft, hvis der inde er et undertryk, og hvis konstruktionerne mod jord er utætte. Jordluft trænger ind gennem revner og utætte samlinger......, fx omkring rør til kloak, vand og varmeforsyning. Koncentrationen af radon i jorden varierer meget fra sted til sted, også lokalt og gennem året. Tidligere undersøgelser har vist, at der kan forekomme høje koncentrationer i Sydgrønland, specielt i området syd for Narsalik ved Paamiut, 61°30’N....

  5. Radon campaigns. Status report 2008

    International Nuclear Information System (INIS)

    Arvela, H.; Valmari, T.; Reisbacka, H.; Niemelae, H.; Oinas, T.; Maekelaeinen, I.; Laitinen-Sorvari, R.

    2008-12-01

    Radon campaigns aim at activating citizens to make indoor radon measurements and remediation as well as increasing the common awareness of indoor radon questions. Indoor radon increases the risk of lung cancer. Through radon campaigns Radiation and Nuclear Safety Authority (STUK) also promotes the attainment of those goals that the Ministry of Social Affairs and Health has set for municipal authorities in Finland for prevention of the harmful effects of radon. The Ministry of Social Affairs and Health supports this campaign. Radon campaigns were started in autumn 2003. By autumn 2008 the campaigns have been organised already in 64 regions altogether in 160 municipalities. In some municipalities they have already arranged two campaigns. Altogether 14 100 houses have been measured and in 2 100 of these the action limit of radon remediation 400 Bq / m 3 has been exceeded. When participating in radon campaigns the house owners receive a special offer on radon detectors with a reduced price. In 2008 a new practice was introduced where the campaign advertisements were distributed by mail to low-rise residential houses in a certain region. The advertisement includes an order / deposit slip with postage paid that the house owner can send directly to STUK to easily make an order for radon measurement. In the previous radon campaigns in 2003 - 2007 the municipal authorities collected the orders from house owners and distributed later the radon detectors. The radon concentrations measured in the campaign regions have exceeded the action limit of 400 Bq / m 3 in 0 - 39% of houses, depending on the region. The total of 15% of all measurements made exceeded this limit. The remediation activities have been followed by sending a special questionnaire on remedies performed to the house owners. In 2006 - 2007 a questionnaire was sent to those households where the radon concentration of 400 Bq / m 3 was exceeded during the two first campaign seasons. Among the households that replied

  6. EPA ENERGY STAR: Tackling Growth in Home Electronics and Small Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Marla Christine; Brown, Richard; Homan, Gregory

    2008-11-17

    Over a decade ago, the electricity consumption associated with home electronics and other small appliances emerged onto the global energy policy landscape as one of the fastest growing residential end uses with the opportunity to deliver significant energy savings. As our knowledge of this end use matures, it is essential to step back and evaluate the degree to which energy efficiency programs have successfully realized energy savings and where savings opportunities have been missed.For the past fifteen years, we have quantified energy, utility bill, and carbon savings for US EPA?s ENERGY STAR voluntary product labeling program. In this paper, we present a unique look into the US residential program savings claimed to date for EPA?s ENERGY STAR office equipment, consumer electronics, and other small household appliances as well as EPA?s projected program savings over the next five years. We present a top-level discussion identifying program areas where EPA?s ENERGY STAR efforts have succeeded and program areas where ENERGY STAR efforts did not successfully address underlying market factors, technology issues and/or consumer behavior. We end by presenting the magnitude of ?overlooked? savings.

  7. RECOMMENDED HVAC STANDARD OF THE FLORIDA RADON RESEARCH PROGRAM

    Science.gov (United States)

    The report contains the recommended language for the heating, ventilation, and air conditioning (HVAC) section of the "Florida Code for Radon-resistant Construction and Mitigation." t deals with elements of construction that relate to the HVAC of houses. ts primary intent is to p...

  8. Radon and its daughters in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Rundo, J

    1984-05-01

    Prolonged exposure to radon should build up a reservoir of radon in body fat and fluids. Movement of the subject to an environment with a lower radon concentration from an environment with a higher level of radon would result in an exhalation of radon, and the initial exhalation rate of radon should depend on the radon concentration inhaled. This paper describes the behavior of radon and its daughters in vivo and a relationship between the radon exhalation rate and the time after a meal. A major but short-lived postprandial increase in the exhalation rate of radon was observed. We report a similar effect in the exhalation rate of radon by persons containing no radium. It should be noted that the possibility exists that a large amount of radon daughters in the chest may interfere in the investigation of possible internal contamination with plutonium or other actinides by external counting. (author).

  9. Radon in balneology - measurement of radon retention by patients and radiation protection for personell

    International Nuclear Information System (INIS)

    Just, G.; Falkenbach, A.; Grunewald, W.A.; Philipsborn, H. von

    2001-01-01

    In radon balneology patients are exposed to radon either from water or air through the skin or through inhalation. Drinking radon water was not included in the study. Previously, the radon transfer has been determined for an estimate of the medically active amount of radon retained in the patient. A simpler approach of measuring radon in expiration under and after exposure has now been standardised and applied to probands under different conditions of exposure. In addition, radon decay products were measured in sweat, saliva and in the skin. Experimental parameters were evaluated for a comparison of different concentrations observed under different conditions. Results are likely to improve both therapy for patients and radiation protection for members of the personnel. (orig.) [de

  10. US EPA overview

    International Nuclear Information System (INIS)

    Rowe, W.D.

    1976-01-01

    EPA believes that effective and efficient solutions to problems in all radioactive waste disposal areas will require close coordination and cooperation among all agencies involved. In this regard, EPA already has participated in meetings with the Energy Research and Development Administration, the Nuclear Regulatory Commission, the Council on Environmental Quality, the U.S. Geological Survey, and the Office of Management and Budget to lay the groundwork for the development of a consolidated national radioactive waste disposal plan. The EPA program is directed first toward developing goals and requirements; and then, in cooperation with the public, industry, the States and Federal agencies, towards determining by what means these goals can be achieved for each waste management option. In addition, the program will develop criteria for determining when the goals of the waste management options have been achieved. In summary, EPA will provide fundamental environmental criteria and generally applicable environmental standards for permanent disposal of high level radwastes. Concurrently, ERDA will develop the necessary technology; and NRC will conduct necessary studies, develop waste-related regulations, and license specific sites and methods of control. Together, we will be able to manage the disposal of the Nation's radioactive waste in an environmentally adequate manner

  11. Radon Mapping of the Osijek Town

    International Nuclear Information System (INIS)

    Radolic, V.; Faj, Z.; Smit, G.; Culo, D.; Planinic, J.

    1998-01-01

    After ten years investigation of radon seasonal variations at three very different locations, as well as radon concentration measurements in kindergartens and schools, systematical indoor radon measurements were undertaken in dwellings of Osijek. Indoor radon was measured by means of the LR-115 nuclear track detector at 48 town locations that gave the arithmetic mean of 71.6 Bq m -3 , standard deviation of 44.0 Bq m -3 and geometric mean of 60.1 Bq m -3 , for the radon concentration range from 23 to 186 Bq m -3 . The empirical frequency distribution of radon concentrations, with the class width of 20 Bq m -3 , was in accordance with the theoretical log-normal distribution which was shown with χ 2 - test. The radon map pointed out a region of higher radon concentrations (central part of the town) that was ascribed to the geological soil structure. Thus supposition was confirmed by radon measurement in the soil gas using radon emanators with the LR-115 film that showed the positive correlation between radon concentrations in the soil and indoors. Radon measurements in Osijeks primary schools pointed out a school that had the highest radon concentration (300 Bq m -3 ) considering all the former indoor radon measurements. The radon distribution in the school building was investigated afterwards radon mitigation procedures were undertaken. (author)

  12. The effect and the amendment of thermoregulation to the stability of radon concentration in radon chamber

    International Nuclear Information System (INIS)

    Zhang Xiongjie; Wang Renbo; Qu Jinhui; Tang Bin; Zhu Zhifu; Man Zaigang

    2010-01-01

    When the temperature in the airtight radon chamber was adjusted, it would induce the frequent changes of the air pressure in chamber, then the radon concentration in the radon chamber would continuously reduce, which could seriously destroy the stability of the radon concentration in radon chamber. In this paper, on the study of the effect reasons to the stability of radon concentration in airtight radon chamber due to the thermoregulation, a new amendment scheme was put forward, and the solutions of the relevant parameters were discussed. The amendment scheme had been successfully applied to HD-6 radon chamber, and achieved good results. (authors)

  13. Excess bottom radon 222 distribution in deep ocean passages

    International Nuclear Information System (INIS)

    Sarmiento, J.L.; Broecker, W.S.; Biscaye, P.E.

    1978-01-01

    Radon 222 and STD profiles were obtained as part of the Geosecs program in the Vema Channel in the southwest Atlantic Ocean and in the Samoan, Clarion, and Wake Island passages in the Pacific Ocean. The standing crop of excess radon 222 is higher in the passages than at other nearby locations. The most likely explanation for this is that there is a high flux of radon 222 from the floor of the passages. Since much of the floor is covered with manganese nodules and encrustations, the high flux of radon 222 may be attributable to the high concentrations of radium 226 in the outer few millimeters of such deposits. Laboratory measurements of radon 222 emissivity from maganese encrustations obtained in Vema Channel support this hypothesis. The excess radon 222 in the Vema Channel and Wake Island Passage is found in substantial quantities at heights above bottom greatly exceeding the heights at which excess radon 222 is found in nonpassage areas. The horizontal diffusion of radon emanating from the walls of the passages is unlikely to be the cause of the observed concentrations because the ratio of wall surface area to water volume is very low. The profiles must therefore be a result of exceptionally high apparent vertical mixing in the passages. Further work is needed to determine the nature of this apparent vertical mixing. The excess radon 222 and STD data in all four passages have been fit with an empirical model in which it is assumed that the bouyancy flux is constant with distance above bottom. The fits are very good and yield apparent buoyancy fluxes that are between 1 and 3 orders of magnitude greater than those obtained at nearby stations outside the passages for three of the four passages

  14. Application of a radon model to explain indoor radon levels in a Swedish house

    International Nuclear Information System (INIS)

    Font, LL.; Baixeras, C.; Joensson, G.; Enge, W.; Ghose, R.

    1999-01-01

    Radon entry from soil into indoor air and its accumulation indoors depends on several parameters, the values of which normally depend on the specific characteristics of the site. The effect of a specific parameter is often difficult to explain from the result of indoor radon measurements only. The adaptation of the RAGENA (RAdon Generation, ENtry and Accumulation indoors) model to a Swedish house to characterise indoor radon levels and the relative importance of the different radon sources and entry mechanisms is presented. The building is a single-zone house with a naturally-ventilated crawl space in one part and a concrete floor in another part, leading to different radon levels in the two parts of the building. The soil under the house is moraine, which is relatively permeable to radon gas. The house is naturally-ventilated. The mean indoor radon concentration values measured with nuclear track detectors in the crawl-space and concrete parts of the house are respectively 75±30 and 200±80 Bq m -3 . Results of the model adaptation to the house indicate that soil constitutes the most relevant radon source in both parts of the house. The radon concentration values predicted by the model indoors fall into the same range as the experimental results

  15. Evaluation of radon-222 concentrations levels at workplaces of Curitiba, PR, Brazil

    International Nuclear Information System (INIS)

    Del Claro, Flavia; Paschuk, Sergei A.; Correa, Janine N.; Kappke, Jaqueline; Perna, Allan F.N.; Reque, Marilson; Martins Neto, Manoel R.; Denyak, Valeriy

    2013-01-01

    The radon is noble radioactive gas, which when inhaled and undergoing spontaneous decay emits alpha particles that interacting with the cells of biological tissue stimulates the development of lung cancer. The isotope 222 Rn is responsible for approximately half of the effective dose received by the population from natural radiation sources. Current work is focused at the evaluation of the radon concentration levels in air of different workplaces at Curitiba-PR. For this purpose 126 track-etched detectors CR-39 were mounted inside the diffusion chambers that were distributed at workplaces of three enterprises environments for a period of three months approximately. The diffusion chambers were protected by a borosilicate glass fiber filters. After the exposition in air the detectors were submitted to chemical etching using a solution of 6.25M NaOH at 70°C during 14 hours. Such chemical treatment enables to count alpha particle track using an optical microscope with 100x objective magnification. The density of alpha particle tracks in CR-39 was converted to the radon activity concentration in air using the results of previous calibration performed at the National Institute of Radiological Sciences (NIRS) in Japan. Obtained results show that the concentration of 222 Rn in air at studied workplaces varied from 16±2 Bq/m³ to 78±9 Bq/m³. These values are considered within the limits established by international regulatory agencies such as EPA and ICRP, which consider as normal the radon activity up to 200 Bq/m³ and 148 Bq/m³, respectively. (author)

  16. Evaluation of radon-222 concentrations levels at workplaces of Curitiba, PR, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Del Claro, Flavia; Paschuk, Sergei A.; Correa, Janine N.; Kappke, Jaqueline; Perna, Allan F.N.; Reque, Marilson; Martins Neto, Manoel R., E-mail: flavia_delclaro@yahoo.com.br, E-mail: spaschuk@gmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba - PR (Brazil); Denyak, Valeriy, E-mail: denyak@gmail.com [Instituto de Pesquisa Pele Pequeno Principe (FPP), Curitiba - PR (Brazil)

    2013-07-01

    The radon is noble radioactive gas, which when inhaled and undergoing spontaneous decay emits alpha particles that interacting with the cells of biological tissue stimulates the development of lung cancer. The isotope {sup 222}Rn is responsible for approximately half of the effective dose received by the population from natural radiation sources. Current work is focused at the evaluation of the radon concentration levels in air of different workplaces at Curitiba-PR. For this purpose 126 track-etched detectors CR-39 were mounted inside the diffusion chambers that were distributed at workplaces of three enterprises environments for a period of three months approximately. The diffusion chambers were protected by a borosilicate glass fiber filters. After the exposition in air the detectors were submitted to chemical etching using a solution of 6.25M NaOH at 70°C during 14 hours. Such chemical treatment enables to count alpha particle track using an optical microscope with 100x objective magnification. The density of alpha particle tracks in CR-39 was converted to the radon activity concentration in air using the results of previous calibration performed at the National Institute of Radiological Sciences (NIRS) in Japan. Obtained results show that the concentration of {sup 222}Rn in air at studied workplaces varied from 16±2 Bq/m³ to 78±9 Bq/m³. These values are considered within the limits established by international regulatory agencies such as EPA and ICRP, which consider as normal the radon activity up to 200 Bq/m³ and 148 Bq/m³, respectively. (author)

  17. CONTRIBUTION OF RADON FLOWS AND RADON SOURCES TO THE RADON CONCENTRATION IN A DWELLING

    NARCIS (Netherlands)

    DEMEIJER, RJ; STOOP, P; PUT, LW

    1992-01-01

    In this paper a model is presented for analysis of the radon concentrations in a compartment in terms of contributions from transport by flows of air between compartments and from radon sources in the compartment. Measurements were made to study the effect of increased natural ventilation of the

  18. Radon and radon daughter monitoring (including thoron daughter monitoring)

    International Nuclear Information System (INIS)

    Leach, V.A.; Grealy, G.; Gan, W.

    1982-01-01

    Radon/radon daughter and thoron daughter measurement techniques are outlined. The necessary precautions and critical assessments of each method are also presented with a view to providing a better understanding of the various measurement methods

  19. Uranium prospecting through radon detection; La prospection de l'uranium par le radon

    Energy Technology Data Exchange (ETDEWEB)

    Pradel, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    Prospecting rests on the determination of the concentration of ground air in radon. Radon diffusing from deep uranium bearing layers is detected in upper ground layers. (author) [French] La prospection est basee sur l'etude de la concentration en radon dans l'air du sol. Dans les terrains superficiels, on decele le radon qui diffuse a partir des couches profondes uraniferes. (auteur)

  20. Certain problems about radon. Pt.1

    International Nuclear Information System (INIS)

    Wu Huishan

    2005-01-01

    Discussion has been made on certain pointed out problems which presently influence the work and development of radon survey, and certain specific problems have been put forward which should be paid much attention and taken measures. Among the problems, some come from cognition, i.e. two kinds of balance and examination about radon, chief culprit of radon's daughter, multiply control and migration, the significance of radon in the water and soil, important standards for designing and evaluating the sites of construction projects, thoughts on the mechanism of the harm of radon and its daughters, diseases causing of both high and low radon, difficulty of emanation of indoor radon, normal low radon from natural marble; and others must be resolved specifically, i.e. establishment of national radon standards as quickly as possible, improvement of on-the-spot examination technique, national-wide radon survey with multiple disciplines and technology, the research on the mechanism of radon's harm and the establishment national radon study center. (authors)

  1. Radon and its daughters in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Rundo, J

    1984-05-01

    Prolonged exposure to radon should build up a reservoir of radon in body fat and fluids. If the subject moved to an environment with a lower radon concentration from an environment with a higher level of radon, the result would be an exhalation of radon, and the initial exhalation rate of radon should depend of the radon concentration inhaled. This paper describes the behavior of radon and its daughters in vivo and a relationship between the radon exhalation rate and the time after a meal. A major but short-lived postprandial increase in the exhalation rate of radon was observed. The author reports a similar effect in the exhalation rate of radon by persons containing no radium. It should be noted that the possibility exists that a large amount of radon daughters in the chest may interfere in the investigation of possible internal contamination with plutonium or other actinides by external counting. 8 figures.

  2. Measurement of exhalation rate of radon and radon concentration in air using open vial method

    International Nuclear Information System (INIS)

    Horiuchi, Kimiko; Ishii, Tadashi.

    1991-01-01

    It was recognized that more than half of total exposure dose on human subject is caused by radon and its decay products which originate from naturally occurring radioactive substances (1988 UNSCEAR). Since then the exhalation of radon from the ground surface has received increasing attention. The authors have developed a new method for the determination of radon in natural water using toluene extraction of radon and applying a liquid scintillation counter of an integral counting technique which is able to get the absolute counting of radon. During these studies, the authors found out that when a counting vial containing of Liquid scintillator (LS)-toluene solution, without a lid, is exposed to the atmosphere for a while, dissolution of radon clearly occurs due to high solubility of radon into toluene layer. To extend this finding for the determination of radon in the atmosphere, the authors devised a new method to actively collect the atmosphere containing radon in a glass bottle by discharging a definite amount of water in it, which is named as open-vial dynamic method. The radon concentration can be easily calculated after the necessary corrections such as the partition coefficient and others. Applying proposed method to measure the radon exhalation rate from the ground surface and radon concentration in air of the dwelling environment, radioactive mineral spring zone and various geological formation such as granitic or sedimentary rocks. (author)

  3. Pawtucket R.I. Group Selected for EPA Environmental Workforce Development and Job Training Program Grant

    Science.gov (United States)

    Groundwork Rhode Island, a Pawtucket-based organization, was one of 17 groups selected today by the U.S. Environmental Protection Agency (EPA) to share $3.3 million to operate environmental job training programs for local citizens.

  4. Risks from radon

    International Nuclear Information System (INIS)

    Doll, Richard

    1992-01-01

    The best estimate of risk to which everyone is exposed from natural radon in buildings is now obtained by extrapolation from observations on men exposed to radon in mines. The relationship between dose and effect derived by the US National Research Council implies that about 6% of the current life-time risk of developing the disease in the UK is attributable to radon, but for residents of some houses it will be much greater. This estimate is dependent on many assumptions, some of which are certainly wrong, and reliable estimates can be obtained only by direct observations on people living in different houses. It is possible that radon may also cause some risk of other cancers, notably leukaemia, but such risks, if real, are certainly small. Studies in progress should provide reliable estimates of all radon induced risks within a few years. (author)

  5. Study of radon concentration and toxic elements in drinking and irrigated water and its implications in Sungai Petani, Kedah, Malaysia

    Directory of Open Access Journals (Sweden)

    Nisar Ahmad

    2015-07-01

    Full Text Available The radon activity concentration and toxic elements have been assessed in drinking and irrigated water samples collected from different locations of Sungai Petani, Kedah, Malaysia. The water samples were collected from wells, streams and taps. A calibrated alpha spectrometer RAD-7 (Model 2890 and Atomic Absorption Spectrometers (Perkin–Elmer, Model AAnalyst 200, Shimadzu, Model AA-700 were used to estimate radon activity concentration and toxic elements, respectively. Maximum average value of radon concentration among the various types of water sources was found 14.7 ± 1.44 Bq/l in well water used for drinking and irrigation and minimum was found 5.37 ± 0.58 Bq/l in tap water used for drinking. Contribution of radon in drinking water to indoor air and age dependent associated annual effective doses were calculated from the measured radon concentration and were found less than lower limit of recommended action level. The activity concentrations of Ni > Pb > Cd > As > Cr were found higher for streams water as compared to wells and tap water. Values of radon concentration in well water were found higher than EPA recommended level and lower than WHO action level while the annual effective doses and level of toxic elements in water reported in this study were found lower than recommended level.

  6. Radon: Detection and treatment

    International Nuclear Information System (INIS)

    Loken, S.; Loken, T.

    1989-01-01

    Within the last few years, natural radon exposure in non-industrial settings, primarily homes, has become a health concern. Research has demonstrated that many homes throughout the United States have radon concentrations much higher than the legal federal limits set for miners. Thousands of unsuspecting people are being exposed to high levels of radiation. It is estimated that up to 15 percent of lung cancers are caused from radon. This is a significant health risk. With basic knowledge of the current information on radon, a primary health care provider can address patients' radon concerns and make appropriate referrals

  7. Radon at the Mauna Loa Observatory: transport from distant continents

    International Nuclear Information System (INIS)

    Whittlestone, S.; Robinson, E.; Ryan, S.

    1992-01-01

    Continuous measurements of radon have been made at an altitude of 3400m at the Mauna Loa Observatory, Hawaii. Concentrations ranged from about 20 to more than 700mBq m -3 . These were similar to values at remote Macquarie I., some 2000 km south of Australia in the Southern Ocean. At Mauna Loa, the radon concentrations could usually be separated into free tropospheric and island influenced categories on the basis of local meteorological observations. On one occasion a long range transport event from Asia brought relatively high radon concentrations to Mauna Loa and persisted for several days. The Asian origin of this event was supported by wind trajectories. This measurement program demonstrates the value of radon data in evaluating air transport models and the influence of transport from distant continents on baseline atmospheric measurements. (author)

  8. Radon in workplaces

    International Nuclear Information System (INIS)

    Gooding, Tracy

    1995-01-01

    The naturally occurring radioactive gas radon has been found at excessive levels in many workplaces other than mines throughout the country. Prolonged exposure to radon and its decay products increases the risk of developing lung cancer, and controls to protect employees from excessive exposure are included in the Ionising Radiations Regulations 1985. The control of occupational exposure to radon is discussed here. (author)

  9. Radon and radon daughter measurements at and near the former Middlesex Sampling Plant, Middlesex, New Jersey

    International Nuclear Information System (INIS)

    Haywood, F.F.; Perdue, P.T.; Christian, D.J.; Leggett, R.W.; Dickson, H.W.; Myrick, T.E.

    1980-03-01

    The results of the radon and radon daughter measurements made to date (1978) at the Middlesex Sampling Plant in Middlesex, New Jersey, are presented in this report. These measurements were one portion of a more comprehensive radiological survey conducted at this site and the surrounding area from 1976 to 1978. The surveyed property served as a uranium ore sampling plant during the 1940's and early 1950's and as a result contains elevated levels of surface an subsurface contamination. On-site indoor radon daughter and radon concentrations exceeded both the US Surgeon General Guidelines and the Nuclear Regulatory Commission's maximum permissible concentration limits for radon (10 CFR Part 20) in all structures surveyed. Off-site structures showed concentrations of radon and radon daughters at or only slightly above background levels, except for one site where the radon levels were found to be above the 10 CFR Part 20 guidelines. Outdoor radon ad radon daughter concentrations, measured both on and off the site, were well below the guidelines, and the data give no indication of significant radon transport from the site

  10. Geographical associations between radon and cancer: is domestic radon level a marker of socioeconomic status?

    International Nuclear Information System (INIS)

    Wolff, S.P.; Stern, G.

    1991-01-01

    Previous studies showing a geographical association between radon and various cancers, particularly the leukaemias and lymphomas, appear to be confounded by the role of radon levels as a surrogate for socioeconomic status. Higher socioeconomic status (at least at the UK county level) is correlated with higher levels of domestic radon. Controlling for the relationship between socioeconomic status and radon removes the correlation between radon exposure and lymphoproliferative disease. Reported associations between radon and lymphoproliferative disease (and possibly other cancers) may be secondary to socioeconomic variables. (author)

  11. Significance of radon exposures in developing cleanup criteria for radium-contaminated soil at the Weldon Spring Site

    International Nuclear Information System (INIS)

    Blunt, D.L.; Peterson, J.M.; Hillman, D.J.

    1993-10-01

    The Weldon Spring site, located in St. Charles County, Missouri, is included on the National Priorities List (NPL) of the US Environmental Protection Agency (EPA), and the US Department of Energy (DOE) is currently conducting cleanup activities at the site. This paper discusses the significance of radon exposures that may result from radium-contaminated soil and the approach currently being taken at the Weldon Spring site to address this issue

  12. Inverse method for determining radon diffusion coefficient and free radon production rate of fragmented uranium ore

    International Nuclear Information System (INIS)

    Ye, Yong-jun; Wang, Li-heng; Ding, De-xin; Zhao, Ya-li; Fan, Nan-bin

    2014-01-01

    The radon diffusion coefficient and the free radon production rate are important parameters for describing radon migration in the fragmented uranium ore. In order to determine the two parameters, the pure diffusion migration equation for radon was firstly established and its analytic solution with the two parameters to be determined was derived. Then, a self manufactured experimental column was used to simulate the pure diffusion of the radon, the improved scintillation cell method was used to measure the pore radon concentrations at different depths of the column loaded with the fragmented uranium ore, and the nonlinear least square algorithm was used to inversely determine the radon diffusion coefficient and the free radon production rate. Finally, the solution with the two inversely determined parameters was used to predict the pore radon concentrations at some depths of the column, and the predicted results were compared with the measured results. The results show that the predicted results are in good agreement with the measured results and the numerical inverse method is applicable to the determination of the radon diffusion coefficient and the free radon production rate for the fragmented uranium ore. - Highlights: • Inverse method for determining two transport parameters of radon is proposed. • A self-made experimental apparatus is used to simulate radon diffusion process. • Sampling volume and position for measuring radon concentration are optimized. • The inverse results of an experimental sample are verified

  13. Radon exhalation rates corrected for leakage and back diffusion – Evaluation of radon chambers and radon sources with application to ceramic tile

    Directory of Open Access Journals (Sweden)

    M. Abo-Elmagd

    2014-10-01

    Full Text Available The natural radon decay, leakage and back diffusion are the main removal processes of radon from its container. Ignoring these processes leads to underestimate the measured value of radon related parameters like exhalation rate and radium content. This work is aimed to evaluate two different radon chambers through determining their leakage rate λv and evaluation of radon source by determine its back diffusion rate λb inside the evaluated radon chambers as well as a small sealed cup. Two different methods are adapted for measuring both the leakage rate and the back diffusion rate. The leakage rate can be determined from the initial slope of the radon decay curve or from the exponential fitting of the whole decay curve. This can be achieved if a continuous monitoring of radon concentration inside the chamber is available. Also, the back diffusion rate is measured by sealing the radon source in the chamber and used the initial slope of the buildup curve to determine λb and therefore the exhalation rate of the source. This method was compared with simple equation for λb based on the ratio of the source to the chamber volume. The obtained results are applied to ceramic tile as an important radon source in homes. The measurement is targeted the ceramic glaze before and after firing as well as the obtained tile after adhere the glaze on the tile main body. Also, six different tile brands from Egyptian market are subjected to the study for comparison.

  14. Studies of Radon and Radon Progeny in Air Conditioned Rooms in Hospitals

    International Nuclear Information System (INIS)

    Marley, F.; Denman, A.R.; Phillips, P.S.

    1998-01-01

    A series of continuous real-time radon and radon progeny measurements together with passive etched track detector measurements were performed in hospital premises during 1996. In one small room, detailed measurements over several weeks showed that both the radon concentration and the Equilibrium Factor depended on the intermittent operation of a filtered positive pressure displacement air-conditioning system, which was designed to conform to operating theatre standards. The average radon level measured while the air-conditioning was off was almost four times higher than that recorded whilst it was on. The progeny level was over five times higher than that whilst it was on. Thus, the Equilibrium Factor (F), was significantly lower when the air-conditioning was on. Measurements in similar rooms in two hospitals, confirmed that the reduction in radon level was a general finding. Thus staff working in such environments receive significantly lower radiation dose from radon than staff working in nearby normally ventilated rooms. (author)

  15. A comparison of contemporary and retrospective radon gas measurements in high radon dwellings in Ireland

    International Nuclear Information System (INIS)

    Kelleher, K.; McLaughlin, J.P.; Fenton, D.; Colgan, P.A.

    2006-01-01

    Little correlations has been found between contemporary radon gas measurements made in the past and retrospective radon gas measurements in Irish dwellings. This would suggest that these two techniques would result in two significantly different cumulative radon exposure estimates. Contemporary radon gas measurements made a few years apart in the same room of a dwelling were found to be significantly different. None of these differences could be explained by known changes to the rooms themselves., such ventilation or structural alterations to the room. This highlights the limitations of the contemporary radon gas measurements as a surrogate measurement for use in residential radon epidemiology. The contemporary radon gas measurements made by the Radiological Protection Institute of Ireland (R.P.I.I.) and University College of Dublin (U.C.D.) do not cover the same exposure period as the retrospective estimates and so the accuracy of the retrospective measurements cannot be demonstrated. A weak correlation can be seen between the retrospective radon gas estimates and a combination of the two contemporary radon gas estimates. It is not unreasonable to expect improvement in the correlation if further contemporary radon gas measurements were made in these rooms. (N.C.)

  16. Radon in workplaces

    International Nuclear Information System (INIS)

    Markkanen, M.; Annanmaeki, M.; Oksanen, E.

    2000-01-01

    The EU Member States have to implement the new Basic Safety Standards Directive (BSS) by May 2000. The Title VII of the Directive applies in particular to radon in workplaces. The Member States are required to identify workplaces which may be of concern, to set up appropriate means for monitoring radon exposures in the identified workplaces and, as necessary, to apply all or part of the system of radiological protection for practices or interventions. The BSS provisions on natural radiation are based on the ICRP 1990 recommendations. These recommendations were considered in the Finnish radiation legislation already in 1992, which resulted in establishing controls on radon in all types of workplaces. In this paper issues are discussed on the practical implementation of the BSS concerning occupational exposures to radon basing on the Finnish experiences in monitoring radon in workplaces during the past seven years. (orig.) [de

  17. Modeling of indoor radon

    International Nuclear Information System (INIS)

    Paschoa, A.S.

    1990-01-01

    This paper reports on models for radon, which are developed not only to describe the behavior of radon and daughters since the moment that radon is created in natural sources by the alpha decay of 226 Ra up to the point that doses to humans are estimated based on the inhalation of radon and its progeny. The objective of a model should be determinant in defining the model structure and boundaries. Modeling indoors radon is particularly useful when the 226 Ra concentration in building materials and soils can be known before a house will be built with such 226 Ra bearing materials and over 226 Ra rich soils. The reported concentrations of 226 Ra in building materials range from 0.3 Bq · kg -1 in wood to about 2.6 x 10 3 Bq · kg -1 in aerated concrete based on alum shale. 30 In addition, when a house is built on a soil containing a high 226 Ra concentration, radon exhalation from the soil contributes to increase radon concentration indoors. The reported radon exhalation from soils range from 3.4 Bq · m -2 · s -1 in latosolic soil from Osaka, Japan to about 53 mBq · m -2 · s -1 in chernozemic soil from Illinois

  18. Is exposure to over ground radon as dangerous as they say?

    International Nuclear Information System (INIS)

    Krishan Kant

    2007-01-01

    Complete text of publication follows. Natural sources of radioactivity are all around us, and man-made radioactive materials are a vital part of medicine and industry. Exposure to some radiation, natural or man-made, is inevitable. Sixty-eight percent of our exposure to natural sources of radiation usually comes from radon, a colorless, tasteless, and odorless gas that comes from the decay of uranium found in nearly all soils. Radioactive radon gas is widely considered to be a health hazard by environmental agencies in the United States and in Europe. Yet despite the warnings of these agencies, thousands of people annually expose themselves to radon for therapeutic purposes, in facilities ranging from rustic old mines, to upscale spas and clinics. Moreover, while modern biomedicine has been enormously successful in the treatment of acute illnesses, it has dealt less well with chronic illnesses. In living with radiation, we must understand the risks and benefits. In order to assess the risk at high doses, LNT hypothesis of ICRP (and consequently also of IAEA, EU, NCRP, BEIR VI, etc.) is used. Current radiation risk estimates, drawn by linear extrapolation, from high dose and dose rate of radiation from very high and complex miner's data orders of magnitude down to completely different current mining conditions, residential radon doses and dose-rates, and a multitude of other confounding factors, even very careful epidemiological studies have not demonstrated any cancerogenic radon effects up to levels around 1000 Bq/m 3 , or ca. 7 times the EPA limit. This paper addresses the possibility that the LNT model may not be applicable for low doses of radon, and that low doses of radon may in fact be beneficial for certain chronic illnesses. There are growing numbers of studies indicating an inverse relationship between cancer occurrence and low dose environmental radon exposure, as well as numerous studies examining the therapeutic effects of low dose radiation. This

  19. Scopingsreport Radon

    NARCIS (Netherlands)

    Blaauboer RO; Vaas LH; Hesse JM; Slooff W

    1989-01-01

    Dit scopingsrapport vormt een onderdeel van de voorbereiding tot het opstellen van het basisdocument radon. Het doel van dit rapport is het algemene kennisniveau van de deelnemers aan de scopingsbijeenkomst aangaande radon op eenzelfde peil te brengen en discussie- en beslispunten inzake de

  20. Radon in dwellings

    International Nuclear Information System (INIS)

    Erikson, B.E.; Boman, C.A.; Nyblom, L.; Swedjemark, G.A.

    1980-06-01

    The report presents the function of the ventilation by natural draught in three-storey houses. In some cases also the measurement of gamma radiation, radon and radon daughters was made. The investigation took place in Uppsala. The houses were built of light weight concrete made of alum-shale. The measurements showed that the contents of radon daughters were far below the provisional limits. (G.B.)

  1. Application of a radon model to explain indoor radon levels in a Swedish house

    CERN Document Server

    Font, L; Jönsson, G; Enge, W; Ghose, R

    1999-01-01

    Radon entry from soil into indoor air and its accumulation indoors depends on several parameters, the values of which normally depend on the specific characteristics of the site. The effect of a specific parameter is often difficult to explain from the result of indoor radon measurements only. The adaptation of the RAGENA (RAdon Generation, ENtry and Accumulation indoors) model to a Swedish house to characterise indoor radon levels and the relative importance of the different radon sources and entry mechanisms is presented. The building is a single-zone house with a naturally-ventilated crawl space in one part and a concrete floor in another part, leading to different radon levels in the two parts of the building. The soil under the house is moraine, which is relatively permeable to radon gas. The house is naturally-ventilated. The mean indoor radon concentration values measured with nuclear track detectors in the crawl-space and concrete parts of the house are respectively 75+-30 and 200+-80 Bq m sup - sup 3...

  2. Protocol for the estimation of average indoor radon-daughter concentrations: Second edition

    International Nuclear Information System (INIS)

    Langner, G.H. Jr.; Pacer, J.C.

    1988-05-01

    The Technical Measurements Center has developed a protocol which specifies the procedures to be used for determining indoor radon-daughter concentrations in support of Department of Energy remedial action programs. This document is the central part of the protocol and is to be used in conjunction with the individual procedure manuals. The manuals contain the information and procedures required to implement the proven methods for estimating average indoor radon-daughter concentration. Proven in this case means that these methods have been determined to provide reasonable assurance that the average radon-daughter concentration within a structure is either above, at, or below the standards established for remedial action programs. This document contains descriptions of the generic aspects of methods used for estimating radon-daughter concentration and provides guidance with respect to method selection for a given situation. It is expected that the latter section of this document will be revised whenever another estimation method is proven to be capable of satisfying the criteria of reasonable assurance and cost minimization. 22 refs., 6 figs., 3 tabs

  3. Comparing summer and winter indoor radon and radon daughters activity in Campinas, Brazil

    International Nuclear Information System (INIS)

    Guedes, O.S.; Hadler, N.J.C.; Iunes, P.J.; Neman, R.S.; Souza, W.F.; Tello, S.C.A.; Paulo, S.R.

    2002-01-01

    We developed a technique - based on alpha particle track detection using CR-39 - where the activity originated from indoor radon can be potentially separated into three fraction: (i) radon in the air, (ii) radon daughters (RD), 218 Po and 214 Po, in the air and (iii) RD plated-out on the detector surface during exposure. In this work only a partial separation was carried out, then our results are limited to radon plus RD in the air and RD attached to detector surface. These activities can be separated if size and gray level of the round tracks are measured using an automatic optical microscopy system.Our group carried out an indoor radon and radon daughters (RD) survey in Campinas made up by a summer (November, 96 to May, 97) and a winter (May, 97 to November, 97) exposure, where the detectors were placed in the same rooms of the same dwellings (approximately 100) in both cases. Comparing winter and summer alpha activity for the detectors analyzed up to now, approximately 45 dwellings, we observed that: i) it seems that the source of radon is the material (brick and concrete mainly) making up walls, floor and ceiling of the dwellings, ii) there is no clear relationship between intensity of aeration and the activities measured in this work, and iii) the average ratio between winter and summer activity in the air (radon plus RD) is approximately equal to similar ratios observed in other countries, but for radon only. (author)

  4. Application of the can technique and radon gas analyzer for radon exhalation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fazal-ur-Rehman E-mail: fazalr@kfupm.edu.sa; Al-Jarallah, M.I.; Musazay, M.S.; Abu-Jarad, F

    2003-12-01

    A passive 'can technique' and an active radon gas analyzer with an emanation container were applied for radon exhalation rate measurements from different construction materials, viz. five marble seven ceramic and 100 granite tiles used in Saudi Arabia. The marble and ceramic tiles did not show detectable radon exhalation using the active radon gas analyzer system. However the granite tiles showed relatively high radon exhalations, indicating a relatively high uranium content. A comparison of the radon exhalation rates measured by the two techniques showed a linear correlation coefficient of 0.57. The radon exhalation rates from the granites varied from 0.02 to 6.58 Bq m{sup -2} h{sup -1} with an average of 1.35{+-}1.40 Bq m{sup -2} h{sup -1}. The geometric mean and the geometric standard deviation of the frequency distribution were found to be 0.80 and 3.1, respectively. The track density found on the nuclear track detectors in the can technique exposed to the granites, having high exhalation rates, varied linearly with exposure time with a linear correlation coefficient of 0.99. This experimental finding agrees with the theoretical prediction. The can technique showed sensitivity to low radon exhalation rates from ceramic, marble and some granite over a period of 2 months, which were not detectable by the active radon gas analyzer system. The reproducibility of data with both measuring techniques was found to be within a 7% deviation.

  5. Indoor radon and radon daughters survey at Campinas-Brazil using CR-39: First results

    International Nuclear Information System (INIS)

    Guedes, S.; Hadler, J.C.N.; Iunes, P.J.; Navia, L.M.S.; Neman, R.S.; Paulo, S.R.; Rodrigues, V.C.; Souza, W.F.; Tello, C.A.S.; Zuniga, A.

    1999-01-01

    The first results of a radon and radon daughters (RD) survey performed at Campinas-SP, Brazil, are presented. We employed a technique that, potentially, makes possible to measure the radon and RD activity in the air and to separate from this result the activity of radon, alone. In this preliminary paper only the former activity is studied

  6. Indoor radon and radon daughters survey at Campinas-Brazil using CR-39: First results

    CERN Document Server

    Guedes, S; Iunes, P J; Navia, L M S; Neman, R S; Paulo, S R; Rodrigues, V C; Souza, W F; Tello, C A S; Zúñiga, A G

    1999-01-01

    The first results of a radon and radon daughters (RD) survey performed at Campinas-SP, Brazil, are presented. We employed a technique that, potentially, makes possible to measure the radon and RD activity in the air and to separate from this result the activity of radon, alone. In this preliminary paper only the former activity is studied.

  7. Levels of radon gas concentration and progeny in homes of Potosi City, Bolivia to 4000 m; Niveles de concentracion de gas radon y progenie en viviendas de la Ciudad de Potosi, Bolivia a 4000 msnm

    Energy Technology Data Exchange (ETDEWEB)

    Mamani M, R. [Universidad Autonoma Tomas Frias, Carrera de Fisica, Av. del maestro s/n, Edif. Central Potosi, Villa Imperial de Potosi (Bolivia, Plurinational State of); Claros J, J. [Universidad Autonoma Tomas Frias, Facultad de Minas Potosi, Centro de Investigacion, Av. Serrudo y Arce s/n, Villa Imperial de Potosi (Bolivia, Plurinational State of); Vasquez A, R., E-mail: raulm2k13@hotmail.com [Instituto Boliviano de Biologia de Altura, Calle Hoyos 953, La Paz (Bolivia, Plurinational State of)

    2015-10-15

    Full text: In this work the presence of radon gas was determined, which is a radioactive contaminant that comes from underground, able to penetrate the houses. The danger is that when mixed air and when inhaled can cause serious damage to the lungs, for the short life time that has radon and progeny for decay, damaging the pulmonary alveoli and reducing breathing capacity of the habitants, then causing polycythemia in some cases. The study was carried out in homes in the city of Potosi, Bolivia located at 4000 m. The quantification of radon gas and progeny was performed with the equipment Alpha-Zaeller-2 (Az-2), quantification was realized in 6 zones of the city of Potosi, chosen randomly. In each zone were carried out measurements in 40 homes (2 rooms more permanent), both day and night, for a period of 3 days in two different seasons and with concentrations of average humidity of 20, 50 and 80%. The values obtained for each period vary depending on the season and 30 to 50% of the allowable values given by the EPA and Who for housing. (Author)

  8. Pollution prevention initiatives at US EPA: 'Green Lights'

    International Nuclear Information System (INIS)

    Lawson, J.; Kwartin, R.

    1991-01-01

    US EPA is initiating a pollution prevention approach to supplement its historic command-control, regulatory approach to environmental protection. EPA believes polllution prevention, where applicable and possible, represents a quicker, less expensive and even profitable strategy for environmental protection. Most clearly, energy-efficiency provides an opportunity to prevent significant amounts of pollution related to the inefficeint generation and use of electricity. EPA's first energy productivity and pollution prevention program is Green Lights. Beyond its own merits, Green Lights will also provide important experience to EPA as it develops its Green Machines program to accelerate the market for efficient appliances and equipment

  9. Radon as a hydrological indicator

    Energy Technology Data Exchange (ETDEWEB)

    Komae, Takami [National Research Inst. of Agricultural Engineering, Tsukuba, Ibaraki (Japan)

    1997-02-01

    The radon concentration in water is measured by a liquid scintillation method. After the radioactive equilibrium between radon and the daughter nuclides was attained, the radon concentration was determined by the liquid scintillation analyzer. {alpha}-ray from radon, then two {beta}- and two {alpha}-ray from the daughter nuclei group were released, so that 500% of the apparent counting efficiency was obtained. The detector limit is about 0.03 Bq/l, the low value, which corresponds to about 5.4x10{sup -15} ppm. By determining the radon concentration in groundwater, behavior of radon in hydrological process, the groundwater exchange caused by pumping and exchange between river water and groundwater were investigated. The water circulation analysis by means of radon indicator in the environment was shown. By using the large difference of radon concentration between in river water and in groundwater, arrival of injected water to the sampling point of groundwater was detected. (S.Y.)

  10. Control of radon in Finnish workplaces

    International Nuclear Information System (INIS)

    Markkanen, M.

    2002-01-01

    Natural radiation in Finland is regulated in the Finnish Radiation Act from 1992. Occupational exposure to natural radiation is regulated by an amendment of the Radiation Decree in 1998. The most important issues in Finland are radon in workplaces, radioactivity in drinking water and in building materials, and mining and industrial processes. Radon levels in mines have been measured regularly since 1972. Finland has an action level for radon in workplaces of 400 Bq/m 3 . Radon prone areas have been identified primarily from measurements of radon in dwellings. Radon measurements are compulsory in workplaces in radon prone areas unless it can be shown by other means that radon levels are low. A programme focusing on radon in workplaces was initiated in 1992. To date, radon measurements have been carried out in 10,000 workplaces and remedial actions have been taken in 200 of these. The average reduction in radon concentration in remediated buildings is about 1,500 Bq/m 3 . Identification of NORM industries is based on the radionuclide content of the materials used (>1.4 Bq/g U and >0.4 Bq/g Th). The occupational exposure should not exceed 1 mSv/y (excluding radon)

  11. Radon mitigation in schools

    International Nuclear Information System (INIS)

    Leovic, K.W.; Craig, A.B.; Saum, D.W.

    1990-01-01

    This article reports on radon mitigation in school buildings. Subslab depressurization (SSD) has been the most successful and widely used radon reduction method in houses. Thus far, it has also substantially reduced radon levels in a number of schools. Schools often have interior footings or thickened slabs that may create barriers for subslab air flow if a SSD system is the mitigation option. Review of foundation plans and subslab air flow testing will help to determine the presence and effect of such barriers. HVAC systems in schools vary considerable and tend to have a greater influence on pressure differentials (and consequently radon levels) than do heating and air-conditioning systems encountered in the radon mitigation of houses. As part of any radon mitigation method, ASHRAE Standard 62-1989 should be consulted to determine if the installed HVAC system is designed and operated to achieve minimum ventilation standards for indoor air quality

  12. Health effects of radon

    International Nuclear Information System (INIS)

    Easterly, C.

    1994-01-01

    Exposure of people to radon has taken on increased interest during the last decade because of the understanding that buildings can serve to trap radon and its daughters, and thereby build up undesirable concentrations of these radioactive elements. Numerous studies of underground miners (often uranium miners) have shown an increased risk of lung cancer in comparison with nonexposed populations. Laboratory animals exposed to radon daughters also develop lung cancer. The abundant epidemiological and experimental data have established the carcinogenicity of radon progeny. Those observations are of considerable importance, because uranium, from which radon and its progeny arise, is ubiquitous in the earth's crust, including coal mines. Risk estimates of the health effects of long-term exposures at relatively low levels require continued development, especially to address the potential health effects of radon and radon daughters in homes and occupational settings where the exposure levels are less than levels in underground uranium and other metal mines that have been the subject of epidemiological studies. Two approaches can be used to characterize the lung-cancer risks associated with radon-daughter exposure: mathematical representations of the respiratory tract that model radiation doses to target cells and epidemiological investigation of exposed populations, mainly underground uranium miners. The mathematically-based dosimetric approach provides an estimate of lung cancer risk related to radon-daughter exposure based specifically on modeling of the dose to target cells. The various dosimetric models all require assumptions, some of which are not subject to direct verification, as to breathing rates; the deposition of radon daughters in the respiratory tract; and the type, nature, and location of the target cells for cancer induction. The most recent large committee effort drawn together to evaluate this issue was sponsored by the National Research Council

  13. Poster: Report Fraud Waste and Abuse to the EPA OIG Hotline

    Science.gov (United States)

    The EPA OIG hotline receives complaints of fraud, waste, and abuse in EPA and U.S. Chemical Safety Board programs and operations including mismanagement or violations of law, rules, or regulations by EPA employees or program participants.

  14. Radon risk in the house; Il rischio radon nelle abitazioni

    Energy Technology Data Exchange (ETDEWEB)

    Bressa, G. [Padua Univ., Padua (Italy). Dipt. di Farmacologia e Anestesiologia, Lab. di Tossicologia

    2001-04-01

    Radon was discovered in 1900, but its potential dangerousness for man was fully understood only in 1950. Being a radioactive natural gas - and therefore particularly dangerous - radon results from the long decay chain of radionuclides, such as thorium and radium. Some igneous rocks (granite, tufa and lava) as well as coal are considered to be the main sources of this radionuclide. A number of epidemiologic studies have shown the carcinogenicity of this element, particularly among miners and workers subjected to high level exposure in confined spaces such as basements, garages, cellars, etc. There are, however, some techniques to remove radon in order to reduce exposure to minimum values. [Italian] Il radon fu scoperto nel 1900, ma solo nel 1950 si comprese la sua potenziale pericolosita' per l'uomo. Il radon e' particolarmente pericoloso essendo un gas naturale radioattivo. Esso proviene dalla lunga catena di decadimento di radionuclidi come il torio e di radio. Sorgenti di tale radionuclide sono da considerarsi principalmente alcune rocce ignee (graniti, tufi e lave) e il carbone. Diversi studi epidemiologici hanno evidenziato la cancerogenicita' di tale elemento, specie tra i minatori e soggetti esposti ad alti livelli in ambienti confinati quali scantinati, garage sotterranei, ecc.. Esistono comunque tecniche di intervento per la rimozione del gas radon in modo tale da ridurre l'esposizione a valori minimi.

  15. Radon evasion rates in the Atlantic and Pacific oceans as determined during the Geosecs program

    International Nuclear Information System (INIS)

    Peng, T.; Broecker, W.S.; Mathieu, G.G.; Li, Y.; Bainbridge, A.E.

    1979-01-01

    During the Geosecs expedition in the Atlantic and the Pacific oceans, more than 100 stations were occupied for the measurement of surface radon profiles. The radon deficiency in these profiles gives estimates of the gas transfer rate across the sea-air interface. The global mean transfer rate is estimated to be 2.9 m/d (at 20 0 C) which is corresponding to a hypothetical stagnant films thickness of about 36 microns. No clear relationship can be found between the gas exchange rate and wind speed. The CO 2 exchange rate as determined by the radon method is 80% of that given by the distributions of natural and of bomb-produced radiocarbon. One possible explanation may be that the Geosecs radon measurements were made during periods of lower than average wind speed. Another is that the conversion of CO 2 to HCO 3 - is catalyzed within the sea

  16. Radon in Syrian houses

    International Nuclear Information System (INIS)

    Othman, I.; Hushari, M.; Raja, G.; Alsawaf, A.

    1996-01-01

    A nationwide investigation of radon levels in Syrian houses was carried out during the period 1991-1993. Passive radon diffusion dosemeters using polycarbonate detectors were distributed in houses all over Syria. Detectors were subjected to electrochemical etching to reveal latent tracks of alpha particles. The mean radon concentration in Syrian houses was found to be 45 Bq m -3 with some values several times higher. This investigation indicated that there were a few houses in Syria that require remedial action. Most houses that have high levels of radon were found in the southern area, especially in the Damascus governorate. The study also indicated that radon concentrations were higher in old houses built from mud with no tiling. (author)

  17. The therapeutic use of radon; Radon als Heilmittel

    Energy Technology Data Exchange (ETDEWEB)

    Deetjen, P [Innsbruck Univ. (Austria). Inst. fuer Physiologie und Balneologie

    1995-09-01

    Spas with a somewhat elevated concentration of Radon{sup 222} (between 300 and 3000 Bq/l) are described to achieve good clinical results in the treatment of chronic rheumatic diseases. Recently a prospective randomized doubel-blind-study proved the pain reducing efficacy of Radon therapy in patients with cervical pain. Studies in experimental animal models have accumulated remarkable data in tissues and organs that provide a rationale to explain the observed effects of Radon therapy in patients. (orig.) [Deutsch] In verschiedenen europaeischen und asiatischen Laendern werden oft schon seit vielen Jahrhunderten Quellen als besonders heilkraeftig beschrieben, die eine etwas erhoehte Aktivitaet an Radon{sup 222} aufweisen (etwas zwischen 300 und 3000 Bq/l). Neuerdings liegt auch eine prospektive randomisierte Doppelblind-Studie vor, die den klinischen Nachweis der Schmerzlinderung durch eine Radonkur erbringt. In tierexperimentellen Untersuchungen wurden unter Radonexposition zahlreiche stimulierende Effekte auf Zellstoffwechsel, Immunabwehr, Abbau toxischer Radikale, DNA-Reparatur-Systeme oder Synthese von Mediatorsubstanzen gemessen, die rationale Ansaetze fuer das Verstaendnis der Wirkung einer Radonexposition im niedrigen Dosisbereich ergeben. (orig.)

  18. Radon and its measurement

    International Nuclear Information System (INIS)

    Penzo, Silvia

    2006-03-01

    The work reviews the topics concerning the problem of the indoor radon and its measurement. The initial stage deals with the general features of radon, from the historical remarks about its discovery to the formation mechanisms in the soil, then passing to describe the transport processes that lead the radon to enter into the buildings. The mean radon concentration distribution among the Italian regions is reported and compared with the situation in the other countries of the world. A particular importance is given to present the national law concerning the radioprotection from the natural sources of ionizing radiations; a paragraph is completely devoted to this argument and to discuss the differences between the Italian approach and the regulations applied in the Test of Europe for both workplaces and dwellings. Chapter 3 describes the different detectors and methods to measure the radon and its short mean live decay products concentrations, together with the operative procedures and guides provided by the Italian law and by the international bodies. As an example of typical radon passive measurement device. the new ENEA detector developed at the Institute of Radioprotection is presented and discussed. Appendix 1 is entirely devoted to discuss the main remedial actions for decreasing the radon indoor concentration both for old and new buildings; appendix 2 reports the main quantities related to radon and radioprotection [it

  19. Radon in public buildings

    International Nuclear Information System (INIS)

    Schulz, H.; Flesch, K.; Hermann, E.; Loebner, W.; Leissring, B.

    2009-01-01

    From the Free State of Saxony, a study was commissioned to survey how reliable measurements to characterize the radon situation in public buildings at a reasonable financial and human effort can be carried out to reduce radiation exposure in public buildings. The study approach was for 6 objects. To characterize the radon situation the time evolution measurement of radon concentrations of more than 1 to 2 weeks turned out to be sufficient. A novel data analysis enables the identification of a ''typical daily alteration of the radon concentration'' depending on the ventilation conditions and the daily use of the offices or class rooms. The identification of typical diurnal radon variations for the working time and weekends or holidays is of fundamental importance for assessing the exposure situation in public buildings. It was shown that the radon concentration during working time are in general much lower than in the times when the buildings (offices) are unused. It turned out that the long-term radon measurements with nuclear track detectors within distinct time regimes (day / night, working hours / leisure time) by utilizing switch modules are very efficient to estimate the actual exposure. (orig.)

  20. Improved thomas formula for radon measurement

    International Nuclear Information System (INIS)

    Ji Changsong

    1991-06-01

    The FT 648 type portable absolute radon meter has been developed and the designing principle of this instrument is introduced. The absolute radon meter differs from relative radon meter. By using structure parameters, operating parameters and readout of this instrument, the radon content of measured gas is obtained directly without calibration in advance. Normally, the calibration is done by a standard radioactive gaseous source of which the radon concentration is known. The systematic error is removed by adding filter-efficiency Σ, α self-absorption correction β, energy spectrum correction S, geometric factor Ω of probe and gravity dropping correction factor G to the Thomas formula for radon measurement of two-filter method. The atmosphere radon content, which is given in hour-average, in Beijing area was measured by FT 648 type absolute radon meter. The measurement lasted continuously for several days and nights and a 'saddle shape' of radon content-time curve was observed. The day's average radon content was 8.5 Bq·m -3

  1. Technique and equipment for measuring volume activity of radon in the air of radon laboratories and clinics

    International Nuclear Information System (INIS)

    Vorob'ev, I.B.; Krivokhatskij, A.S.; Nekrasov, E.V.; Nikolaev, V.A.; Potapov, V.G.; Terent'ev, M.V.

    1990-01-01

    Usability of a new equipment-technique combination for measuring radon activity in the air of radon laboratories and balneological clinics is studied. The complex includes nitrate-cellulose detector, radon chamber, Aist, Istra type spark counters and technique of spark counting. The method sensitivity is 50 Bqxm 3 , the error is 30%. Usability and advisability of track method in radon laboratories and balneological clinics for simultaneous measurement in several points of integral volumetric radon activities are confirmred. The method permits to carry out rapid and accurate bulk investigations. The results of determining mean volumetric radon activity in the air in different points of radon laboratory and radon clinics are presented

  2. Radon in dwellings the national radon survey Cork and Kerry

    International Nuclear Information System (INIS)

    McGarry, A.T.; Fennell, S.G.; Mackin, G.M.; Madden, J.S.

    1998-07-01

    This report presents the results of the third phase of the National Radon Survey carried out by the Radiological Protection Institute of Ireland. The counties included in this phase are Cork and Kerry. The average radon concentrations for the houses measured in these counties were 76 Bq/m 3 and 70 Bq/m 3 . The measurement data were grouped on the basis of the 10 km grid squares of the Irish National Grid System and used to predict the percentage of dwellings in each grid square which exceeds the Reference Level of 200 Bq/m 3 . Grid squares where this percentage is predicted to be 10% or higher are designated High Radon Areas. The health effects of exposure to high radon levels are discussed and recommendations are made regarding both new and existing dwellings. (author)

  3. Geographical information system for radon gas from soil measurement; Il sistema informativo territoriale per la valutazione del potenziale di esalazione di radon dal suolo

    Energy Technology Data Exchange (ETDEWEB)

    Orlando, P.; Amici, M.; Altieri, A.; Massari, P.; Miccadei, E.; Onofri, A.; Orlando, C.; Paolelli, C.; Paron, P.; Perticaroli, P.; Piacentini, T.; Silvestri, C. [Milan Univ. Sacro Cuore, Milan (Italy). Servizio Centralizzato Radioisotopi; Belli, M.; Marchetti, A.; Petrocchi, A.; Rosamilia, S.; Serva, L.; Singh, G.; Tommasino, L. [Agenzia Nazionale per la Protezione dell' Ambiente, Rome (Italy); Minach, L.; Verdi, L. [Agenzia Provinciale per la Protezione dell' Ambiente, Bolzano (Italy); Bertolo, A.; Trotti, F. [Agenzia Regionale per la Protezione dell' Ambiente, Regione Veneto (Italy)

    2000-07-01

    The working program foresees the realization of an geographical information system for the check in field of the geological parameters and determination of uranium and radium contents in various type of rocks. It is here also pointed out a measuring method for radon concentration in soil. [Italian] In questo documento viene presentato il lavoro svolto fino ad oggi: dalla definizione dei parametri geologici ritenuti piu' significativi per la presenza di radon nel suolo e dalle misure in campo e in laboratorio, fino alla realizzazione del Sistema Informativo Territoriale (SIT) per la gestione dei suddetti parametri. Nel primo capitolo sono descritte le caratteristiche del radon, dal punto di vista chimico-fisico e geologico, per introdurre i criteri adottati nella scelta dei paramentri geologici e del loro peso per la valutazione del PERS (Potenziale di Esalazione Radon dal Suolo). Il secondo capitolo descrive il progetto in generale, mentre i successivi capitoli descrivono piu' in dettaglio la parte informatica e quella delle indagini sperimentali.

  4. U. S. EPA voluntary programs and the oil and gas industry : Natural Gas STAR and Energy STAR Buildings Partnership

    International Nuclear Information System (INIS)

    Gunnung, P.

    2000-01-01

    The structure of two EPA programs directed towards wasted energy in buildings, reducing emissions, increasing energy efficiency and maximizing profits are described. The programs are based on a partnership approach between EPA and participants, and involve elements of plans and performance benchmarks, an integrated approach and communications and demonstration of successful initiatives. EPA provides planning and technical support in the form of a website, software tools, manuals, electronic sources and a purchasing tool kit. The Energy STAR Building Partnership has over 3,000 participants, and can boast of a cumulative saving of over $ 1.4 billion in energy bills and carbon dioxide emission reduction of 44.1 billion pounds, resulting from efficiency upgrades. The Natural Gas Partnership between the EPA and the oil and natural gas industry to cost effectively reduce methane emissions from the production, transmission, and distribution of natural gas also has had a number of successful initiatives such as replacement or retrofit of high bleed pneumatic devices, installation of flash tank separators on glycol dehydrators and other partner-reported projects such as replacement of wet seals with dry seals on compressors and connecting glycol pump to vapour recovery unit. As a results of these and other initiatives, annual methane emission was reduced by 22.2 bcf in 1998 as opposed to 3.4 bcf prior to the beginning of the program in 1993. Approximately 67 per cent of all reductions can be attributed to partner innovation. Overall assessment is that the program is innovative, achieves both economic and environmental goals, facilitates government and industry cooperation and is living proof that non-regulatory, cooperative programs work

  5. Radon programmes and health marketing.

    Science.gov (United States)

    Fojtikova, Ivana; Rovenska, Katerina

    2011-05-01

    Being aware of negative health effects of radon exposure, many countries aim for the reduction of the radon exposure of their population. The Czech radon programme was commenced >20 y ago. Since then experts have gathered a lot of knowledge, necessary legislation has been enacted, tens of thousands of inhabitants have been offered free measurement and subsidy for the mitigation. Despite the effort, the effectiveness of the radon programme seems to be poor. Newly built houses still exhibit elevated radon concentrations and the number of houses mitigated is very low. Is it possible to enhance the effectivity of radon programme while keeping it on a voluntary basis? One possible way is to employ health marketing that draws together traditional marketing theories and science-based strategies to prevention. The potential of using marketing principles in communication and delivery of radon information will be discussed.

  6. Leukaemia risks and radon

    International Nuclear Information System (INIS)

    Wolff, S.P.

    1991-01-01

    A correlation has been established between domestic radon exposure and mutation in peripheral T lymphocytes. Some caution must be exercised, however, in interpreting this result as evidence that levels of domestically encountered radon are sufficient to cause leukaemogenic chromosomal alterations. Radon may simply be acting as a surrogate for some other mutagenic factor. Correlations with Local Authority statistics collected in the United Kingdom 1981 Census appear to show that lower domestic radon levels reflect relatively greater socioeconomic deprivation whereas higher levels reflect greater prosperity. The relative risk of lymphoproliferative disease correlates with the same factors that determine domestic radon levels at the county level. Putative relationships between domestic radon exposure and cancer thus need to be controlled for socioeconomic status and associated factors, at least at the county level. (The correlations may not apply to smaller areas.) Similarly, the causative factors underlying the relationships between higher regional socioeconomic status and leukaemia require closer examination. (author)

  7. Radon in workplaces: First results of an extensive survey and comparison with radon in homes

    International Nuclear Information System (INIS)

    Bucci, S.; Pratesi, G.; Viti, M. L.; Pantani, M.; Bochicchio, F.; Venoso, G.

    2011-01-01

    Extensive radon surveys have been carried out in many countries only in dwellings, whereas surveys in workplaces are rather sparse and generally restricted to specific workplaces/activities, e.g. schools, spas and caves. Moreover, radon-prone areas are generally defined on the basis of radon surveys in dwellings, while radon regulations use this concept to introduce specific requirements in workplaces in such areas. This approach does not take into account that work activities and workplace characteristics can significantly affect radon concentration. Therefore, an extensive survey on radon in different workplaces have been carried out in a large region of Italy (Tuscany), in order to evaluate radon distribution in workplaces over the whole territory and to identify activities and workplace characteristics affecting radon concentration. The results of this extensive survey are compared with the results of the survey carried out in dwellings in the same period. The workplaces monitored were randomly selected among the main work activities in the region, including both public and industrial buildings. The survey monitored over 3500 rooms in more than 1200 buildings for two consecutive periods of ∼6 months. Radon concentration was measured by means of passive nuclear track detectors. (authors)

  8. The significance of radon in radioactive pollution of environment. Pt. 2. Radon effect on living organism

    International Nuclear Information System (INIS)

    Kossakowski, S.; Dziura, A.; Kossakowski, A.

    1998-01-01

    Authors review the history of radon monitoring. Epidemiological studies of lung cancer and its correlation to radon concentration in mines and buildings are described. The influence of radon on animals living in the buildings built from waste materials is described. Authors review plans concerning creation of radon monitoring system in Poland. The necessity of monitoring influence of radon on animals is described

  9. Monitoring of radon concentration in dwellings

    International Nuclear Information System (INIS)

    Kurosawa, Ryuhei

    1991-01-01

    Radon problems in dwellings have recently received much attention. Radon concentration in dwellings, as well as in the general environment, varies with various factors such as meteorological conditions and soil components. Therefore, a long term monitoring of radon concentration is required to obtain an average concentration. This paper reviews a passive type radon monitor that is handy and allows a long term radon monitoring. It provides the structure and principle of the radon monitor, covering the type, filter function, sensitivity of diffusion collecting type (cup type), electrostatic collecting type, adsorption collecting type, and detector of radon monitor. Actual examples of the radon monitor are also given. Radon daughter nuclides will have become major foci of exposure countermeasures. In the future, the development of a passive type monitor for determining potential alpha energy concentration is required. (N.K.)

  10. Intercomparison of active and passive instruments for radon and radon progeny in North America

    International Nuclear Information System (INIS)

    George, A.C.; Tu, Keng-Wu; Knutson, E.O.

    1995-02-01

    An intercomparison exercise for radon and radon progeny instruments and methods was held at the Environmental Measurements Laboratory (EML) from April 22--May 2, 1994. The exercise was conducted in the new EML radon test and calibration facility in which conditions of exposure are very well controlled. The detection systems of the intercompared instruments consisted of. (1) pulse ionization chambers, (2) electret ionization chambers, (3) scintillation detectors, (4) alpha particle spectrometers with silicon diodes, surface barrier or diffused junction detectors, (5) registration of nuclear tracks in solid-state materials, and (6) activated carbon collectors counted by gamma-ray spectrometry or by alpha- and beta-liquid scintillation counting. 23 private firms, government laboratories and universities participated with a 165 passive integrating devices consisting of: Activated carbon collectors, nuclear alpha track detectors and electret ionization chambers, and 11 active and passive continuous radon monitors. Five portable integrating and continuous instruments were intercompared for radon progeny. Forty grab samples for radon progeny were taken by five groups that participated in person to test and evaluate their primary instruments and methods that measure individual radon progeny and the potential alpha energy concentration (PAEC) in indoor air. Results indicate that more than 80% of the measurements for radon performed with a variety of instruments, are within ±10% of actual value. The majority of the instruments that measure individual radon progeny and the PAEC gave results that are in good agreement with the EML reference value. Radon progeny measurements made with continuous and integrating instruments are satisfactory with room for improvement

  11. Program management strategies for following EPA guidance for remedial design/remedial action at DOE sites

    International Nuclear Information System (INIS)

    Hopper, J.P.; Chew, J.R.; Kowalski, T.E.

    1991-01-01

    At the US Department of Energy (DOE) facilities, environmental restoration is being conducted in accordance with Federal Facilities Compliance Agreements (or Interagency Agreements). These agreements establish a cooperative working relationship and often define roles, responsibilities and authorities for conduct and oversight of the Remedial Action Programs. The US Environmental Protection Agency (EPA) has guidelines on how to initiate and perform remedial actions for sites they are remediating under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA) as amended by the Superfund Amendments and Re-Authorization Act (SARA). This paper addresses some of the difference and commonalities between the DOE project management procedures and EPA guidance documents. This report covers only the RD/RA phase of environmental restoration. On the surface, there are many apparent differences between the DOE and EPA project management processes. Upon closer review, however, many of the differences are the result of applying different terminology to the same phase of a project. By looking for the similarities in the two processes rather than hunting for differences, many communication problems are avoided. Understanding both processes also aids in figuring out when, how and to what extent EPA should participate in the RD/RA phase for DOE lead cleanup activities. The DOE Remedial Design and Remedial Action process is discussed in a stepwise manner and compared to the EPA process. Each element of the process is defined. Activities common to both the EPA and DOE are correlated. The annual DOE budget cycle for remediation projects and the four-year cycle for appropriation of remediation funds are discussed, and the constraints of this process examined. DOE orders as well as other requirements for RD/RA activities are summarized and correlated to EPA regulations where this is possible

  12. Workshop on dosimetry for radon and radon daughters

    International Nuclear Information System (INIS)

    Turner, J.E.; Holoway, C.F.; Loebl, A.S.

    1978-05-01

    Emphasis is placed on the dosimetry for radon and daughters, rather than on monitoring and instrumentation. The objectives of the meeting were to exchange scientific information, to identify problem areas in radon-daughter dosimetry, and to make any observations or recommendations by the participants through issuance of this report. The discussion topics included the history of dosimetry for radon and daughters, human data, aerosols, deposition and movement in the respiratory tract, dose calculations, dose-to-working-level-month (WLM) conversion factors, animal experiments, and the development of regulations and remedial criteria for reducing population exposures to radon daughters. This report contains a summary of Workshop discussions plus individual statements contributed by several of the participants. The outstanding problem areas from the standpoint of dosimetry appear to involve the appropriate lung organ mass to be used (average lung-tissue dose vs. high-level local dose); recognition of the discrete, rather than continuous, structure of the mucus; lack of knowledge about lung clearance; the variability of dose with the degree of disequilibrium and the unattached fraction of radon daughters for a given WLM; and questions about the character of uranium mine atmospheres actually breathed in the older mines from which much of the epidemiological information originates. The development of criteria for taking remedial action to reduce exposures involves additional concerns of basing long-term risk assessment on short-term sampling and applying WLM data for miners to general populations

  13. The Montana Radon Study: social marketing via digital signage technology for reaching families in the waiting room.

    Science.gov (United States)

    Larsson, Laura S

    2015-04-01

    I tested a social marketing intervention delivered in health department waiting rooms via digital signage technology for increasing radon program participation among priority groups. I conducted a tri-county, community-based study over a 3-year period (2010-2013) in a high-radon state by using a quasi-experimental design. We collected survey data for eligible participants at the time of radon test kit purchase. Radon program participation increased at the intervention site (t38 = 3.74; P = .001; 95% confidence interval [CI] = 4.8, 16.0) with an increase in renters (χ(2)1,228 = 4.3; P = .039), Special Supplementary Nutrition Program for Women, Infants, and Children families (χ(2)1,166 = 3.13; P = .077) and first-time testers (χ(2)1,228 = 10.93; P = .001). Approximately one third (30.3%; n = 30) attributed participation in the radon program to viewing the intervention message. The intervention crossover was also successful with increased monthly kit sales (t37 = 2.69; P = .01; 95% CI = 1.20, 8.47) and increased households participating (t23 = 4.76; P signage technology by 2 health departments.

  14. The Pennsylvania radon story

    International Nuclear Information System (INIS)

    Gerusky, T.M.

    1987-01-01

    In December 1984, the Pennsylvania Bureau of Radiation Protection found itself confronted with the discovery of a home in eastern Pennsylvania having the highest level of radon daughters ever reported. The Bureau responded with a massive radon monitoring, educational, and remediation effort. As of November, 1986, over 18,000 homes had been screen for radon daughters, of which approximately 59% were found to have levels in excess of the 0.020 Working Level guideline. Pennsylvania's response to the indoor radon problem is detailed in this article

  15. Radon problems

    International Nuclear Information System (INIS)

    Cohen, B.L.

    1985-01-01

    This chapter examines the health hazards resulting from the release of naturally occurring radioactive gas derived from the decay of uranium. It is estimated that random inhalation is now causing about 10,000 fatal lung cancers per year in the US. Radon is constantly being generated in rocks and soils (in which uranium is naturally present) and in materials produced from them (e.g., brick, stone, cement, plaster). It is emphasized that radon levels in buildings are typically 5 times higher than outdoors because radon diffusing up from the ground below or out of bricks, stone, cement, or plaster is trapped inside for a relatively long time

  16. Unattached radon daughter atoms and radon daughter equilibrium ratios in uranium mines. Final report

    International Nuclear Information System (INIS)

    Holaday, D.A.

    1972-01-01

    Uranium mines in Colorado and New Mexico were surveyed for airborne concentrations of radon (10043922) and radon daughters. A procedure for measuring individual daughters and the fraction of each existing as free atoms was developed and used for field monitoring. Samples were taken in working areas and particle counts were made. The data was analyzed to determine the ratio of radon to radon daughters as well as the ratios among the radon daughters. The author concludes that since the radon to working level ratios have not changed much in 20 years, using the ratio as the basis for estimating relative biological hazard is just as uncertain now as then. The large number of daughters present as free atoms indicate that the lung radiation doses calculated using any of the lung models need reexamination

  17. Decommissioning/closeout of Malargue site: measurement of radon daughter

    International Nuclear Information System (INIS)

    Avila Cadena, Guadalberto

    2000-01-01

    In Malargue complex there are about 700,000 mt of uranium tailings disposed off during 32 years of operation of the Malargue facility. The objective of the Malargue Site is to undertake the necessary actions to execute remediation programs. A summary of measurements of concentrations of radon daughter taken in different buildings of the city and in the field shows the influence of radon source. The results obtain for concentrations of radon daughter indicate that they do not differ significantly between each others. The environmental remediation of uranium mill tailings at Malargue Site is a requirement of Nuclear Regulatory Authority (NRA) and of the Mendoza province and a commitment to reduce the doses as low as reasonably achievable, social and economic factors being taken into account (ALARA concept). (author)

  18. Radon - The management of the risk related to radon

    International Nuclear Information System (INIS)

    2010-01-01

    This leaflet briefly explains what radon is, where it comes from, and what it becomes. It indicates and briefly comments its concentrations in French departments, describes how radon can affect our health (lung cancer), describes how the risk can be reduced in buildings, and indicates the existing regulatory provisions

  19. Radon programmes and health marketing

    International Nuclear Information System (INIS)

    Fojtikova, I.; Rovenska, K.

    2011-01-01

    Being aware of negative health effects of radon exposure, many countries aim for the reduction of the radon exposure of their population. The Czech radon programme was commenced >20 y ago. Since then experts have gathered a lot of knowledge, necessary legislation has been enacted, tens of thousands of inhabitants have been offered free measurement and subsidy for the mitigation. Despite the effort, the effectiveness of the radon programme seems to be poor. Newly built houses still exhibit elevated radon concentrations and the number of houses mitigated is very low. Is it possible to enhance the effectivity of radon programme while keeping it on a voluntary basis? One possible way is to employ health marketing that draws together traditional marketing theories and science-based strategies to prevention. The potential of using marketing principles in communication and delivery of radon information will be discussed. (authors)

  20. Simulation model of lung cancer incidence related to smoking and radon daughter exposure

    International Nuclear Information System (INIS)

    Stolowijk, J.A.J.

    1990-01-01

    A mathematical model of lung cancer and radon daughter exposure is presented. It is aimed to provide a quantitative estimate in the form of dose-effect relationship. The nature of the cigarette smoking and radon exposure interaction it is shown to be a multiplicative or sub-multiplicative function rather than a simpler model in which the effect of the two exposures would be summed. The model was written in the SAS programming language. An annotated listing of the program is given. 4 refs

  1. Radon in buildings

    International Nuclear Information System (INIS)

    Ryan, N.M.; Finn, M.

    1995-01-01

    This guide is intended to inform designers, contractors, householders and other building owners about radon in buildings and to provide guidance where it has been decided to take action to reduce radon levels. It gives some pointers to good practice insofar as it relates to non complex buildings of normal design and construction. Reference is made to the usual ways of reducing l;levels of radon and guidance is given on sources of further information. I

  2. Levels of radon gas concentration and progeny in homes of Potosi City, Bolivia to 4000 m

    International Nuclear Information System (INIS)

    Mamani M, R.; Claros J, J.; Vasquez A, R.

    2015-10-01

    Full text: In this work the presence of radon gas was determined, which is a radioactive contaminant that comes from underground, able to penetrate the houses. The danger is that when mixed air and when inhaled can cause serious damage to the lungs, for the short life time that has radon and progeny for decay, damaging the pulmonary alveoli and reducing breathing capacity of the habitants, then causing polycythemia in some cases. The study was carried out in homes in the city of Potosi, Bolivia located at 4000 m. The quantification of radon gas and progeny was performed with the equipment Alpha-Zaeller-2 (Az-2), quantification was realized in 6 zones of the city of Potosi, chosen randomly. In each zone were carried out measurements in 40 homes (2 rooms more permanent), both day and night, for a period of 3 days in two different seasons and with concentrations of average humidity of 20, 50 and 80%. The values obtained for each period vary depending on the season and 30 to 50% of the allowable values given by the EPA and Who for housing. (Author)

  3. Radon in dwellings the national radon survey Galway and Mayo

    International Nuclear Information System (INIS)

    McGarry, A.T.; Fennell, S.G.; Mackin, G.M.; Madden, J.S.; O'Colmain, M.

    1999-07-01

    This report presents the results of the final phase of the National Radon Survey carried out by the Radiological Protection Institute of Ireland. The counties included in this phase are Galway and Mayo. The average radon concentrations for the houses measured in these counties were 112 Bq/m 3 and 100 Bq/m 3 , respectively. The measurement data were grouped on the basis of the 10 km grid squares of the Irish National Grid System and used to predict the percentage of dwellings in each grid square which exceeds the Reference Level of 200 Bq/m 3 . Grid squares where this percentage is predicted to be 10% or higher are designated High Radon Areas. The health effects of exposure to high radon levels are discussed and recommendations are made regarding both new and existing dwellings. (author)

  4. The use of mechanical ventilation with heat recovery for controlling radon and radon-daughter concentrations

    International Nuclear Information System (INIS)

    Nazaroff, W.W.; Boegel, M.L.; Hollowell, C.D.; Roseme, G.D.

    1980-01-01

    An energy research house in Maryland was found to have radon concentrations far in excess of recommended guidelines. A mechanical ventilation system with heat recovery was installed in this house to test its effectiveness as an energy-efficient control technique for indoor radon. Radon concentration was monitored continuously for two weeks under varying ventilation conditions (0.07 to 0.8 air changes per hour (ach)) and radon daughter concentrations were measured by grab-sample techniques about nine times daily during this period. At ventilation rates of 0.6 ach and higher radon and radon daughter levels dropped below guidelines for indoor concentrations. Comparison with other studies indicates that indoor radon buildup may be a problem in a considerable portion of houses characterized by their low infiltration rates. The use of mechanical ventilation systems with air-to-air heat exchangers may offer a practical, cost-effective, and energy-efficient means of alleviating not only the radon problem specifically but also the general deterioration of indoor air quality in houses designed or retrofitted to achieve low infiltration

  5. Measurement of radon concentration in water using the portable radon survey meter.

    Science.gov (United States)

    Yokoyama, S; Mori, N; Shimo, M; Fukushi, M; Ohnuma, S

    2011-07-01

    A measurement method for measuring radon in water using the portable radon survey meter (RnSM) was developed. The container with propeller was used to stir the water samples and release radon from the water into the air in a sample box of the RnSM. In this method, the measurement of error would be water was >20 Bq l(-1).

  6. Determination of radon flux rates in a uranium mine (Cluff Lake, Saskatchewan)

    International Nuclear Information System (INIS)

    1989-12-01

    The Atomic Energy Control Board contracted SENES Consultants Limited to design and implement a field program at Amok Limited's Cluff Lake uranium mine, with the overall objective of obtaining reliable radon flux data applicable for use in the VENTRAD computer model. The VENTRAD model was developed to model underground mine ventilation systems. To avoid the uncertainties inherent in localized flux measurements made on small surfaces, radon flux measurements were determined through measurement of incremental changes in the concentration of radon between the incoming and outgoing air in selected areas of the underground workings. The locations were selected throughout the mine in both ore and sterile rock. Average radon flux rates measured during three field campaigns were as follows: sterile rock decline 4 pCi/m 2 .second; sterile rock mainway 25 pCi/m 2 .second; worked-out stope 100 pCi/m 2 .second; active work stope 240 pCi/m 2 .second; and work face 14,000 pCi/m 2 .second. Data collected during the three field programs were used to validate the VENTRAD computer model. The results of the validation exercise suggest close agreement between predicted and measured air flow rates and radon concentrations were overestimated for areas immediately impacted by auxiliary ventilation fans and ore transfer mill holes which connect the ore extraction and haulage levels of the mine

  7. Investigating Indoor Radon Levels and Influencing Factors in Primary Schools of Zulfi City, Saudi Arabia

    International Nuclear Information System (INIS)

    Al-Ghamdi, S. S.; Al-Garawi, M. S.; Al-Mosa, Tahani M.; Baig, M. R.

    2011-01-01

    Measurement of indoor Concentrations were performed in Zulfi city of Saudi Arabia, using CR-39 track etch detectors. This investigation focused on the influence of different parameters, namely different locations, school categories, school building types, and room type as well as on the existence of differences in radon concentration at floor levels. We divided the Zulfi city into five regions, keeping in mind their geographical locations between Tuwaiq Mountains and Al-Thuwayrat sands. The measured average radon concentrations for regions 1-5 respectively are: 87.0±14.2 Bq/m 3 , 83.4±6.0 Bq/m 3 , 61.6±6.4 Bq/m 3 , 63.7±5.4 Bq/m 3 and 87.5±6.Bq/m 3 and the minimum concentrations are 28.0 Bq/m 3 , 5.5 Bq/m 3 , 1.1 Bq/m 3 , 1.0 Bq/m 3 and 24 Bq/m 3 respectively. These results are still within normal limits and below the action level of 148 Bqm -3 set by the U.S. Environmental Protection Agency (EPA). A test of significance using Minitab program was applied to investigate if radon levels in regions are significantly different from each other. We tried all combinations, and found the following results. The ''within regions''(different location) test yielded, region 2 is not significant versus region ''1''(p = 0.783) and versus region ''5''(P = 0.646), whereas it is significant versus region ''3''(P = 0.0160) and also versus region ''4''(p = 0.018). We investigated government and rented school's building also and none was found significantly different (p = 0.052). Floors of the same building were tested in order to examine the radon concentration as a function of storey level. No significant difference was observed at floor levels (p = 0.009). When girl's schools versus Boys and kindergartens schools were tested they were found significantly different. It is believed that this significant difference is due to geographical nature of the area, since most of the girl's schools were selected from regions 2 and 3, these regions are relatively close to the Tuwaiq

  8. 1981 radon barrier field test at Grand Junction uranium mill tailings pile

    International Nuclear Information System (INIS)

    Hartley, J.N.; Gee, G.W.; Baker, E.G.; Freeman, H.D.

    1983-04-01

    Technologies to reduce radon released from uranium mill tailings are being investigated by Pacific Northwest Laboratory as part of the Department of Energy's Uranium Mill Tailings Remedial Action Project (UMTRAP) Technology development program. These technologies include: (1) earthen cover systems, (2) multilayer cover systems, and (3) asphalt emulsion radon barrier systems. During the summer of 1981, a field test was initiated at the Grand Junction, Colorado, uranium tailings pile to evaluate and compare the effectiveness of each radon barrier system. Test plots cover about 1.2 ha (3 acres). The field test has demonstrated the effectiveness of all three cover systems in reducing radon release to near background levels ( 2 s - 1 ). In conjunction with the field tests, column tests (1.8 m diameter) were initiated with cover systems similar to those in the larger field test plots. The column tests allow a direct comparison of the two test procedures and also provide detailed information on radon transport

  9. Nationwide occurrence of radon and other natural radioactivity in public water supplies

    Energy Technology Data Exchange (ETDEWEB)

    Horton, T. R.

    1985-10-01

    The nationwide study, which began in November of 1980, was designed to systematically sample water supplies in all 48 contiguous states. The results of the study will be used, in cooperation with EPA's Office of Drinking Water, to estimate population exposures nationwide and to support possible future standards for radon, uranium, and other natural radioactivity in public water supplies. Samples from more than 2500 public water supplies representing 35 states were collected. Although we sampled only about five percent of the total number of groundwater supplies in the 48 contiguous states of the US, those samples represent nearly 45 percent of the water consumed by US groundwater users in the 48 contiguous states. Sample results are summarized by arithmetic mean, geometric mean, and population weighted arithmetic mean for each state and the entire US. Results include radon, gross alpha, gross beta, Ra-226, Ra-228, total Ra, U-234, U-238, total U, and U-234/U-238 ratios. Individual public water supply results are found in the appendices. 24 refs., 91 figs., 51 tabs.

  10. Radon and radiation biology of the lung

    International Nuclear Information System (INIS)

    Crameri, R.; Burkart, W.

    1989-01-01

    The main papers presented at the meeting dealt with the behaviour of radon and the indoor environment, radiation biology of the lung, lung dosis and the possible cancer risk caused by radon in homes, contamination of the room air. A series of special papers treated the radon problem in detail: sources and transport mechanisms of radon, geological aspects of the radon radiation burden in Switzerland, radon in homes, search for radon sources, and the Swiss radon-programme RAPROS. 67 figs., 13 tabs., 75 refs

  11. Multivariate signal processing in measurements of radon and radon daughters in air

    International Nuclear Information System (INIS)

    Urbanski, P.; Machaj, B.

    2000-01-01

    Extensive measurements of radon and radon daughters concentration gauge in a radon chamber were carried out. Count rate 'spectra' against time at the output of radiation detectors were measured and registered. The count rate spectra were then processed employing Principal Component Regression (PCR). A root mean square error of the count rate was estimated. It was found that PCR processing removes a great part of count rate random fluctuations originating from the radiation statistics that results in a decrease of count rate random error. The root mean square error of count rate in a radon daughter monitor is about 3 times lower, which is equivalent to the error of the gauge with a 9 times higher air flow rate if no PCR processing is used. In case of the radon concentration gauge the increase of sensitivity is even higher and amounts to 5 times. (author)

  12. Variation of radon levels in US homes with various factors

    International Nuclear Information System (INIS)

    Cohen, B.L.; Gromicko, N.

    1988-01-01

    A program combining 70,000 purchased and 3500 random selection-no charge measurements with extensive questionnaires is described. Methods for reducing biases in purchased measurements have been reasonably successful. Distributions are roughly lognormal with σ/sub g/ ≅ 3.0 but with an excess of very high measurements. Winter and spring-fall measurements average about 60 percent and 40 percent, respectively, higher than summer measurements. Basements average 2.5 times higher radon levels than upper floors. Tightening of homes since 1974 has increased radon levels by less than 10 percent, but well-weatherized houses have ∼ 40 percent higher levels than poorly weatherized houses. Open windows reduce levels by a factor of about 2.5. Low-cost newer houses have much lower levels than more expensive newer houses, but among older houses this is reversed. Low income families have substantially lower radon levels than average. There is little variation with education level. Nonsmokers have higher radon levels than smokers, but this seems to apply mainly to living rooms and dining rooms. Suburban houses have higher levels than urban, and rural houses have still higher levels. Owner-occupied houses have much higher levels than rented houses. Variations of radon levels with weatherization do not seem to be due to cost factors. A strategy for locating areas with high mean radon levels is described

  13. EPA`s program for risk assessment guidelines: Quantification issues

    Energy Technology Data Exchange (ETDEWEB)

    Dourson, M.L. [Environmental Protection Agency, Washington, DC (United States)

    1990-12-31

    The quantitative procedures associated with noncancer risk assessment include reference dose (RfD), benchmark dose, and severity modeling. The RfD, which is part of the EPA risk assessment guidelines, is an estimation of a level that is likely to be without any health risk to sensitive individuals. The RfD requires two major judgments: the first is choice of a critical effect(s) and its No Observed Adverse Effect Level (NOAEL); the second judgment is choice of an uncertainty factor. This paper discusses major assumptions and limitations of the RfD model.

  14. Radon measurements in indoor workplaces

    International Nuclear Information System (INIS)

    Tokonami, S.; Matsumoto, M.; Furukawa, M.; Fujimoto, K.; Fujitaka, K.; Pan, J.; Kurosawa, R.

    1996-01-01

    Radon measurements in several office buildings located in Tokyo were carried out with two types of device to study the time-dependent radon concentration in indoor workplaces. Both types of device use the electrostatic field for the collection of 218 Po onto the electrode of the detector. One provides an average radon concentration throughout the day. The other, in which a weekly timer is installed in the circuit of the electrode of the device, provides an average radon concentration during working hours (9:00-17:00, Monday-Friday). Although radon concentrations in Japanese dwellings have been found to be generally low, relatively high concentrations were observed in the office buildings. No consistent seasonal variation was recognised in this study. Little difference of average radon concentrations between working hours and the whole day was found throughout the year in two offices. On the other hand, a significant difference was observed in other offices. The operation of an air conditioner might change the radon concentration during working hours. From the results of radon measurements the average effective dose in the workplace was estimated to be 0.23 mSv for 2000 working hours in a year. (Author)

  15. Radon studies in Indian dwellings

    International Nuclear Information System (INIS)

    Khan, A.J.

    2000-01-01

    The indoor radon ( 222 Rn) concentration has been measured by Solid State Nuclear Track Detectors (SSNTDs) in large number of Indian dwellings. Radon concentrations were measured in different parts of the country. In the first study, radon concentrations were measured in 143 dwellings of Udaipur, Bikaner and Banswara towns of Rajasthan province. The distributions of the time-averaged indoor radon concentration in these three towns of the Rajasthan fit an approximately log normal distribution. The geometric mean (GM) values of radon concentrations in these three places were found to be 74 Bq m -3 , 46 Bq m -3 and 66 Bq m -3 with a geometric standard deviation (GSD) of 2.2, 2.2 and 2.5 respectively. In another study, radon concentrations were measured in about 150 dwellings of hilly regions of the country. The measurements were carried out in Kohima (Nagaland), Baijnath and Palampur (Himachal Pradesh). The distribution of radon concentration in Kohima dwellings was found to be approximately log normal, however, the radon distribution in Baijnath and Palampur dwellings seems to be bimodal. The GM values of the radon concentrations for 65 dwellings in Kohima and 43 dwellings in Baijnath and Palampur were 88 Bq m -3 and 134 Bq m -3 with GSD of 1.7 and 2.5 respectively. The results are discussed in detail. (author)

  16. Some results from the demonstration of indoor radon reduction measures in block basement houses. Report for June 1985-February 1987

    International Nuclear Information System (INIS)

    Henschel, D.B.; Scott, A.G.

    1987-03-01

    The paper gives results of tests of active soil-ventilation techniques in 24 block-wall basement houses in eastern Pennsylvania having significantly elevated indoor radon concentrations, generally above 740 Bq/cu m. The results indicate that radon levels can be reduced substantially (often below the U.S. EPA guideline of 148 Bq/cu m) if effective suction can be drawn on the soil underneath the concrete slabs of these houses. Such effective suction appears achievable when either: (a) the house has a complete loop of drain tile around its footings for water drainage purposes, and suction is drawn on that loop; or (b) a sufficient number of suction pipes can be inserted at the proper locations into the crushed rock or soil underneath the slab

  17. Radon prevention coating in hot and humid environment

    International Nuclear Information System (INIS)

    Yang Yushan; Dong Faqin; Deng Yuequan; Qu Ruixue

    2013-01-01

    The radon prevention performance of a new self-made radon prevention coating was researched in the radon contamination provided by the releasing radon modules. With coating thickness of 0.8 mm, the radon mitigation efficiency in 1 # radon module concentration is optimal when the addition of defoaming agent is 0.3% (mass fraction). The radon mitigation efficiency increases with the coating thickness when the defoaming agent of 0.3% is added, but the radon mitigation efficiency tends to be stable as the coating thickness is more than 2.0 mm. The radon mitigation efficiency of radon prevention coating appended precipitated barium sulphate decreases obviously, and the addition of ash calcium, white cement and gesso don't decrease radon mitigation efficiency. The addition of white cement and gesso addition affects the radon prevention stability, while radon mitigation efficiency of radon prevention coating with ash calcium keeps a good performance. Under the hot and humid environment, the radon prevention coating still has good radon mitigation efficiency in 2 # radon module concentration. (authors)

  18. Radon in homes: The Alaskan experience

    International Nuclear Information System (INIS)

    Seifert, R.D.

    1990-01-01

    For the past four years, since radon was first found to be a concern in Alaska in 1986, the interest and awareness of radon as a special housing and health concern has continued to grow. This paper will discuss the features of a house in Alaska which would characterize it as at risk for radon, and also those efforts at mitigation which have been most effective in reducing radon under Alaskan conditions. Clearly radon must be able to enter a home in order to be a problem. Riefenstuhl and Kline (personal communication, 1988) have analyzed the conditions for radon transport from soils to home interiors very lucidly through the following scheme: four factors must exist in a house locale for it to be a radon at risk house. Two of the factors are geological in nature: (1) there must be adequate uranium and therefore ample radon to provide a source for transport; (2) there must be enough permeability in the soil to allow rapid soil gas movement to carry radon from its origin to the interior of the home within two half-lives of time (six days) or so. The other two factors are determined by the structure of the house itself and the way in which it is operated: (3) the house must have soil contact and imperfections, holes, cracks, intentional perforations which allow movement of soil gas with radon through the envelope of the basement or crawlspace; (4) there must be a lower pressure inside the house than in the soil so that soil gas flows into the house. All four of these characteristics are required to have radon be a problem. The absence of any single characteristic will eliminate radon (in general). This presents a series of options for mitigation of radon then, since elimination of any of the four characteristics will mitigate radon

  19. Monitoring for radon in water

    International Nuclear Information System (INIS)

    Deininger, R.A.

    1994-01-01

    This article focuses on radionuclides elements of interest to utilities and consumers alike. Each of these groups may be interested in a low-cost radiation detector that can be connected to a laptop or desktop computer through either the serial or the parallel port. A complete set of software comes with the detector, and a detailed manual describes operation of the program and discusses the various forms of common radiation sources in a home. Computer programs can run in the foreground and display a scrolling bar chart or in the background while the incoming data are logged, so the user can continue to work on the computer. Data are automatically stored on a disk file. Data collection times can be set for minutes, hours, days, or weeks, thus allowing long-term trends to be identified. The detector can be connected to the computer by a modular telephone cable and can be placed as far away as several hundred feet. Utilities that use surface water supplies are unlikely to detect any radon. Only those plants that use groundwater supplies from areas where radioactive materials are in the ground will have some radon in the water

  20. A calibration facility for radon fluxmeter

    International Nuclear Information System (INIS)

    Li Xianjie; Qiu Shoukang; Zhou Jianliang; Liu Chunkui; Pan Jialin; Yang Mingli

    1998-01-01

    Calibration facilities for radon fluxmeter with three kinds of different emanation medium have been developed. The stability of radon flux is 5%, 9% (RSD) respectively. The uniformity of radon flux is 4.5%, 8.5% (RSD) respectively. These specifications fulfill the calibration requirement for radon fluxmeter. The determination of radon flux of facility takes full account of eliminating the main error source-attenuation effect (including leakage and back diffusion etc.): not only prevent attenuation and make a relevant correction. Therefore the accuracy of determination is assured. The calibration, intercomparison of radon flux meter and the quantitatively evaluation on the measurement method of radon flux are made to be possible by the successful establishment of this facility. (author)

  1. Automatically processed alpha-track radon monitor

    International Nuclear Information System (INIS)

    Langner, G.H. Jr.

    1993-01-01

    An automatically processed alpha-track radon monitor is provided which includes a housing having an aperture allowing radon entry, and a filter that excludes the entry of radon daughters into the housing. A flexible track registration material is located within the housing that records alpha-particle emissions from the decay of radon and radon daughters inside the housing. The flexible track registration material is capable of being spliced such that the registration material from a plurality of monitors can be spliced into a single strip to facilitate automatic processing of the registration material from the plurality of monitors. A process for the automatic counting of radon registered by a radon monitor is also provided

  2. The householders' guide to radon

    International Nuclear Information System (INIS)

    1988-06-01

    This guide is a follow-up to the leaflet Radon in Houses which was issued previously by the Department of the Environment. It is intended for people who live in areas with high levels of radon. It is written particularly for householders whose homes have already been tested and found to have an appreciable level of radon. It explains what radon is, how it gets into houses and what the effects on health may be. It also outlines some of the ways of reducing the level of radon and gives guidance both on how to get the work done and likely costs. (author)

  3. Radon surveys and their implications

    International Nuclear Information System (INIS)

    Miles, J.C.H.; Cliff, K.D.; Dixon, D.W.; Green, B.M.R.; Strong, J.C.

    1989-01-01

    In the UK, as in other countries, radon daughter inhalation is the most significant cause of human exposure to ionising radiation either at home or at work whether one considers the mean or the maximum dose. Substantial studies of radon are under way in the UK, and the importance of radon is recognised in several spheres. NRPB investigations of the radon levels in buildings and mines are reported, the distributions of doses presented and risk factors calculated. The bases of radon limitation for workers and members of the public are given and the means of compliance discussed. (author)

  4. Radon exposure and lung cancer

    International Nuclear Information System (INIS)

    Planinic, J.; Vukovic, B.; Faj, Z.; Radolic, V.; Suveljak, B.

    2003-01-01

    Although studies of radon exposure have established that Rn decay products are a cause of lung cancer among miners, the lung cancer risk to the general population from indoor radon remains unclear and controversial. Our epidemiological investigation of indoor radon influence on lung cancer incidence was carried out for 201 patients from the Osijek town. Ecological method was applied by using the town map with square fields of 1 km 2 and the town was divided into 24 fields. Multiple regression study for the lung cancer rate on field, average indoor radon exposure and smoking showed a positive linear double regression for the mentioned variables. Case-control study showed that patients, diseased of lung cancer, dwelt in homes with significantly higher radon concentrations, by comparison to the average indoor radon level of control sample. (author)

  5. Radon and radon-daughter concentrations in air in the vicinity of the Anaconda Uranium Mill

    International Nuclear Information System (INIS)

    Momeni, M.H.; Lindstrom, J.B.; Dungey, C.E.; Kisieleski, W.E.

    1979-11-01

    Radon concentration, working level, and meteorological variables were measured continuously from June 1977 through June 1978 at three stations in the vicinity of the Anaconda Uranium Mill with measurements integrated to hourly intervals. Both radon and daughters show strong variations associated with low wind velocities and stable atmospheric conditions, and diurnal variations associated with thermal inversions. Average radon concentration shows seasonal dependence with highest concentrations observed during fall and winter. Comparison of radon concentrations and working levels between three stations shows strong dependence on wind direction and velocity. Radon concentrations and working-level distributions for each month and each station were analyzed. The average maximum, minimum, and modal concentration and working levels were estimated with observed frequencies. The highest concentration is 11,000 pCi/m 3 on the tailings. Working-level variations parallel radon variations but lag by less than one hour. The highest working levels were observed at night when conditions of higher secular radioactive equilibrium for radon daughters exist. Background radon concentration was measured at two stations, each located about 25 km from the mill, and the average is 408 pCi/m 3 . Average working-level background is 3.6 x 10 -3

  6. External gamma exposure to radon progeny in indoor air

    International Nuclear Information System (INIS)

    Fujimoto, Kenzo

    1985-01-01

    The external γ-exposure from radon progeny uniformly distributed in indoor air was estimated by a computer program that was developed. This program can calculate the fluence rate, exposure rate and average energy for any given point in a room of any given size. As numerical example, the exposure rate normalized to unit airborne activity is presented, together with the fluence-weighted and exposure-weighted average photon energies, for a room of representative geometry containing radon progeny in equilibrium. To cover other conditions encountered in practice, quantitative evaluations are additionally presented of the effect on the exposure brought by changes in certain parameters, such as equilibrium factor, wall thickness, room size and receptor position. The study has quantitatively substantiated the prevailing postulate that the effective dose equivalent due to external exposure resulting from normal indoor concentrations of airborne radon progeny in the room of representative geometry should only amount to 0.04 % of that from the internal exposure from the same sources, and that it should be of similarly negligible order compared with internal exposure also in the case of other room geometries. (author)

  7. Consumer's Guide to Radon Reduction

    Science.gov (United States)

    ... Labs and Research Centers Radon Contact Us Share Consumer's Guide to Radon Reduction: How to Fix Your ... See EPA’s About PDF page to learn more. Consumer's Guide to Radon Reduction: How to Fix Your ...

  8. The ORNL Indoor Air Quality Study: Re-cap, Context, and Assessment on Radon

    Energy Technology Data Exchange (ETDEWEB)

    Tonn, Bruce Edward [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rose, Erin M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ternes, Mark P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-10-01

    As part of the retrospective evaluation of the U.S. Department of Energy s low-income Weatherization Assistance Program that was led by Oak Ridge National Laboratory (ORNL), an assessment of the impacts of weatherization on indoor air quality (IAQ) was conducted. This assessment included nearly 500 treatment and control homes across the country. Homes were monitored for carbon monoxide, radon, formaldehyde, temperature and humidity pre- and post-weatherization. This report focuses on the topic of radon and addresses issues not thoroughly discussed in the original IAQ report. The size, scope and rigor of the radon component of the IAQ study are compared to previous studies that assessed the impacts of weatherization on indoor radon levels. It is found that the ORNL study is by far the most extensive study conducted to date, though the ORNL results are consistent with the findings of the other studies. However, the study does have limitations related to its reliance on short-term measurements of radon and inability to attribute changes in radon levels in homes post-weatherization to specific weatherization measures individually or in combination.

  9. Radon programme in the Czech Republic

    International Nuclear Information System (INIS)

    Hulka, J.; Thomas, J.

    2003-01-01

    The framework of the Radon programme in the Czech republic includes both precautionary measures and interventions. The programme informally started in early eighties has been now incorporated in national legislation (Atomic Act, Radiation Protection Decree, etc.). Aim of precautionary measures is to avert construction of building above natural radiation guidance levels (200 Bq/m 3 for indoor radon concentration and 0.5 Sv/h for gamma dose rate) by protection of new buildings against soil radon ingress, by regulation of natural radioactivity in building materials and supplied water. Aim of interventions is to identify buildings affected by enhanced natural radioactivity and help owners to put into effect reasonable remedial measures. Two sets of intervention levels for indoor natural exposure were established: guidance intervention levels 400 Bq/m 3 (indoor radon), 1.0 Sv/h (indoor gamma dose rate) and limit values 4000 Bq/m 3 and 10 Sv/h. The radon programme is based both on governmental and private activities. The governmental activities include representative and targeted indoor radon survey, subsidy for radon mitigation, mitigation test measurements and public information on radon issue. The private activities include radon measurement (radon index of building site, indoor measurements, radon diagnosis) and remedial measures. More than 100 commercial companies were authorised by Radiation Protection Authority (SUJB) to provide these measurements

  10. Radon survey techniques

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    The report reviews radon measurement surveys in soils and in water. Special applications, and advantages and limitations of the radon measurement techniques are considered. The working group also gives some directions for further research in this field

  11. Comparison of retrospective and contemporary indoor radon measurements in a high-radon area of Serbia

    International Nuclear Information System (INIS)

    Zunic, Z.S.; Yarmoshenko, I.V.; Kelleher, K.; Paridaens, J.; Mc Laughlin, J.P.; Celikovic, I.; Ujic, P.; Onischenko, A.D.; Jovanovic, S.; Demajo, A.; Birovljev, A.; Bochicchio, F.

    2007-01-01

    In Niska Banja, Serbia, which is a high-radon area, a comparison was made between two retrospective radon measuring methods and contemporary radon measurements. The two retrospective methods derive the radon concentrations that occurred in dwellings over longer periods in the past, based on the amount of trapped 210 Po on the surface of glass objects (surface traps, ST) or in the bulk of porous materials (volume traps, VT). Both surface implanted 210 Po in glass objects and contemporary radon in air were measured in 46 rooms, distributed in 32 houses of this radon spa-town, using a dual alpha track detector configuration (CR-39 and LR115) and CR-39 track etched detectors, respectively. In addition to the use of surface trap measurements, in 18 rooms (distributed in 15 houses) VT samples of suitable material were also collected, allowing to compare ST and VT retrospective radon concentration estimates. For each room, contemporary annual radon concentrations (CONT) were measured or estimated using seasonal correction factors. The distribution of the radon concentration in all data sets was found to be close to lognormal (Chi-square test > 0.05). Geometric means (GM) are similar, ranging from 1040 to 1380 Bq m -3 , whereas geometric standard deviations (GSD) for both the retrospective methods are greater than for the CONT method, showing reasonable agreement between VT, ST and CONT measurements. A regression analysis, with respect to the lognormal distribution of each data set, shows that for VT-ST the correlation coefficient r is 0.85, for VT-CONT r is 0.82 and for ST-CONT r is 0.73. Comparison of retrospective and contemporary radon concentrations with regard to supposed long-term indoor radon changes further supports the principal agreement between the retrospective and conventional methods

  12. The use of track registration detectors to reconstruct contemporary and historical airborne radon ( sup 2 sup 2 sup 2 Rn) and radon progeny concentrations for a radon-lung cancer epidemiologic study

    CERN Document Server

    Steck, D J

    1999-01-01

    Epidemiologic studies that investigate the relationship between radon and lung cancer require accurate estimates for the long-term average concentrations of radon progeny in dwellings. Year-to-year and home-to-home variations of radon in domestic environments pose serious difficulties for reconstructing an individual's long-term radon-related exposure. The use of contemporary radon gas concentrations as a surrogate for radon-related dose introduces additional uncertainty in dose assessment. Studies of glass exposed in radon chambers and in a home show that radon progeny deposited on, and implanted in, glass hold promise for reconstructing past radon concentrations in a variety of atmospheres. We developed an inexpensive track registration detector for the Iowa Radon Lung Cancer Study (IRLCS) that simultaneously measures contemporary airborne radon concentrations, surface deposited alpha activity density, and implanted sup 2 sup 1 sup 0 Po activity density. The implanted activity is used to reconstruct the cum...

  13. Test Report Emission Test Program EPA Information Collection Request for Delayed Coking Units 736 Coker Unit

    Science.gov (United States)

    ARI Environmental, Inc. (ARI) was retained by Houston Refining LP (HRO) to conduct an emission test program at their refinery located in Houston, Texas. The testing was conducted on on the 736 Delayed Coking Unit (DCU) in response to EPA's ICR.

  14. Quality assurance for radon measurements in Germany

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Foerster, E.; Schmidt, V.

    2005-01-01

    Full text: Radiation protection regarding work activities at workplaces with naturally occurring radiation has been regulated in the German Radiation Protection Ordinance. Regulations refer only to workplaces where the presence of natural radiation leads to a significant increase in the exposure of workers. These workplaces were identified in the following working areas with enhanced exposures to radon-222: underground mines, including visitor mines and show caves; radon-spas and galleries; water supply and distribution industries. Presently, regulations are being initiated by the German government to limit the exposures to radon in homes. For radon measurements at workplaces passive radon devices for individual monitoring as well as active measuring systems for workplace monitoring can be used. However, passive radon devices are preferred for radon measurements in homes because of low costs and availability in large quantities. To assure the quality of radon measurements the German Federal Office for Radiation Protection (BfS) has established annual interlaboratory comparisons for passive radon devices. The comparisons are carried out in the BfS radon calibration laboratory accredited by the German Calibration Service. Passive radon devices which use solid state track detectors, electrets or activated charcoal can be submitted. Approved radon services which offer radon measurements to determine radon exposure in homes and at workplaces have to pass the comparisons successfully. (author)

  15. Metrology of the radon in air volume activity at the italian radon reference chamber

    Energy Technology Data Exchange (ETDEWEB)

    Sciocchetti, G.; Cotellessa, G.; Soldano, E.; Pagliari, M. [Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, ENEA Centro Ricerche Casaccia Roma (Italy)

    2006-07-01

    The approach of the Italian National Institute of Ionising Radiations (I.N.M.R.I.-ENEA) on radon metrology has been based on a complete and integrated system which can be used to calibrate the main types of {sup 222}Rn in air measuring instruments with international traceability. The Italian radon reference chamber is a research and calibration facility developed at the Casaccia Research Center in Roma. This facility has an inner volume of one m{sup 3}. The wall is a cylindrical stainless steel vessel coupled with an automated climate apparatus operated both at steady and dynamic conditions. The control and data acquisition equipment is based on Radotron system, developed to automate the multitasking management of different sets of radon monitors and climatic sensors. A novel approach for testing passive radon monitors with an alpha track detector exposure standard has been developed. It is based on the direct measurement of radon exposure with a set of passive integrating monitors based on the new ENEA piston radon exposure meter. This paper describes the methodological approach on radon metrology, the status-of-art of experimental apparatus and the standardization procedures. (authors)

  16. Metrology of the radon in air volume activity at the italian radon reference chamber

    International Nuclear Information System (INIS)

    Sciocchetti, G.; Cotellessa, G.; Soldano, E.; Pagliari, M.

    2006-01-01

    The approach of the Italian National Institute of Ionising Radiations (I.N.M.R.I.-ENEA) on radon metrology has been based on a complete and integrated system which can be used to calibrate the main types of 222 Rn in air measuring instruments with international traceability. The Italian radon reference chamber is a research and calibration facility developed at the Casaccia Research Center in Roma. This facility has an inner volume of one m 3 . The wall is a cylindrical stainless steel vessel coupled with an automated climate apparatus operated both at steady and dynamic conditions. The control and data acquisition equipment is based on Radotron system, developed to automate the multitasking management of different sets of radon monitors and climatic sensors. A novel approach for testing passive radon monitors with an alpha track detector exposure standard has been developed. It is based on the direct measurement of radon exposure with a set of passive integrating monitors based on the new ENEA piston radon exposure meter. This paper describes the methodological approach on radon metrology, the status-of-art of experimental apparatus and the standardization procedures. (authors)

  17. Radon Survey in Hospitals in Slovenia

    International Nuclear Information System (INIS)

    Vaupotic, J.

    2003-01-01

    In Slovenia, several radon studies at workplaces have been carried out in last years, supported by the Ministry of Education, Science and Sport, and the Ministry of Health. After radon surveys in kindergartens, schools and homes, within which about 2600 buildings were checked for radon and which provided the level of radon problem in the country, next investigations were focused on the workplaces with potentially higher radon risk. Hence, in the Postojna Cave permanent radon monitoring was introduced in 1995 and comprehensive radon studies were performed: in 5 bigger spas during 1996-1998, in major waterworks and wine cellars in 2001, and in major Slovene hospitals in 2002. This paper reports the results of radon study in 26 major Slovene hospitals, comprising radon concentrations in 201 rooms and dose estimates for 1025 persons working in these rooms. Radon survey in 201 rooms of 26 major hospitals in Slovenia revealed only 7 rooms in which monthly average radon concentration in the indoor air exceeded 400 Bqm -3 . Generally, concentrations in basement were on average for about 30% higher than in ground floor, although exceptionally high values have also been found in the ground floor. For 966 persons (94.2%) of the total of 1025 persons working in the rooms surveyed, the annual effective dose, estimated according to the Basic Safety Standards was below 1 mSv, while for 59 it exceeded 1 mSv. In 7 rooms with more than 400 Bqm -3 in which 16 persons receive between 2.1 and 7.3 mSv per year radon monitoring is continued. (author)

  18. ERRICCA radon model intercomparison exercise

    International Nuclear Information System (INIS)

    Andersen, C.E.; Albarracin, D.; Csige, I.; Graaf, E.R. van der; Jiranek, M.; Rehs, B.; Svoboda, Z.; Toro, L.

    1999-04-01

    Numerical models based on finite-difference or finite-element methods are used by various research groups in studies of radon-222 transport through soil and building materials. Applications range from design of radon remediation systems to more fundamental studies of radon transport. To ascertain that results obtained with these models are of good quality, it is necessary that such models are tested. This document reports on a benchmark test organized by the EU project ERRICCA: European Research into Radon in Construction Concerted Action. The test comprises the following cases: 1) Steady-state diffusive radon profiles in dry and wet soils, 2) steady-state entry of soil gas and radon into a house, 3) time-dependent radon exhalation from a building-material sample. These cases cover features such as: soil heterogeneity, anisotropy, 3D-effects, time dependency, combined advective and diffusive transport of radon, flux calculations, and partitioning of radon between air and water in soil pores. Seven groups participated in the intercomparison. All groups submitted results without knowing the results of others. For these results, relatively large group-to-group discrepancies were observed. Because of this, all groups scrutinized their computations (once more) and engaged in follow-up discussions with others. During this debugging process, problems were indeed identified (and eliminated). The accordingly revised results were in better agreement than those reported initially. Some discrepancies, however, still remain. All in all, it seems that the exercise has served its purpose and stimulated improvements relating to the quality of numerical modelling of radon transport. To maintain a high quality of modelling, it is recommended that additional exercises are carried out. (au)

  19. THE REPUBLIC OF BELARUS RADON DANGER MAP

    Directory of Open Access Journals (Sweden)

    L. A. Chunikhin

    2016-01-01

    Full Text Available Radon is the major contributor to the background exposure of the population. In the world practice, the radon risk or radon potential mapping are used for the radon dose assessment.The aim of this work was a radon danger mapping of the Republic of Belarus to assess the radiation situation and determine the radon hazard critical areas.Materials and methods: The mapping is based on measured values of radon volume activity in the living rooms of different buildings on the territory of the six regions of the Republic of Belarus. We have performed more than 4000 measurements. Integral track radon radiometers based on the polymer Kodak LR-115 film were used to evaluate radon volume activity. Exposure time ranged from 90 to 120 days. The cartogram was built with using the MAPINFO software package.Results: The low levels of radon concentrations were determined in the Brest and Gomel regions, as well as in the southern districts of Minsk and south-western districts of the Mogilev region. The high levels radon concentrations were determined in some districts of the Vitebsk and Grodno regions, as well as in the north-eastern districts of the Mogilev region. About 2–5 times nonuniformity of radon distribution in settlements of the Republic was observed. The radon hazard critical areas with radon concentrations in the range of 200–400 Bq/m3 were found in some districts of the Vitebsk, Grodno and Mogilev regions.Conclusions: The radon risk map of the Republic of Belarus gives the possibility to estimate the existing radiation risk. Taking into account the low efficiency of countermeasures long after the Chernobyl accident, it is necessary to increase the level of radiation protection through the radon mitigation activities or to change the radon normative documents.

  20. Indoor radon concentration in Poland

    International Nuclear Information System (INIS)

    Mamont-Ciesla, K.; Jagielak, J.; Rosinski, S.W.; Sosinka, A.; Bysiek, M.; Henschke, J.

    1996-01-01

    Preliminary survey of Rn concentration indoors by means of track detectors and y-ray dose rate with the use of TLD in almost 500 homes in selected areas of Poland was performed in the late 1980s. It was concluded that radon contributes 1.16 mSv i.e. about 46 per cent of the total natural environment ionizing radiation dose to the Polish population. Comparison of the average radon concentrations in 4 seasons of a year and in 3 groups of buildings: masonry, concrete and wood, revealed that the ground beneath the building structure is likely the dominant source of radon indoors. Since the National Atomic Energy Agency in its regulations of 1988-03-31 set up the permissible limit of the equilibrium equivalent concentration of radon in new buildings (equal 100 Bq/m3), the nation-scale survey project for radon in buildings has been undertaken. These regulations were supposed to take effect in 1995-01-01. The project has 3 objectives: to estimate the radiation exposure due to radon daughters received by Polish population to identify radon-prone areas in Poland to investigate dependence of the indoor radon concentrations on such parameters as: type of construction material, presence (or absence) of cellar under the building, number of floor

  1. Airborne geophysical radon hazard mapping

    International Nuclear Information System (INIS)

    Walker, P.

    1993-01-01

    Shales containing uranium pose a radon health hazard even when covered by several meters of overburden. Such an alum shale in southern Norway has been mapped with a joint helicopter borne electromagnetic (HEM) and radiometric survey. Results are compared with ground spectrometer, radon emanometer and radon gas measurements in dwellings, and a model to predict radon gas concentrations from the airborne data is developed. Since the shale is conductive, combining the HEM data with the radiometric channel allows the shale to be mapped with greater reliability than if the radiometric channel were used alone. Radiometrically more active areas which do not pose a radon gas hazard can thus be separated from the shales which do. The ground follow-up work consisted of spectrometer and radon emanometer measurements over a uranium anomaly coinciding with a conductor. The correlation between the airborne uranium channel, the ground uranium channel and emanometry is extremely good, indicating that airborne geophysics can, in this case, be used to predict areas having a high radon potential. Contingency tables comparing both radon exhalation and concentration in dwellings with the airborne uranium data show a strong relationship exists between exhalation and the airborne data and while a relationship between concentration and the airborne data is present, but weaker

  2. Accurate measurement of indoor radon concentration using a low-effective volume radon monitor

    International Nuclear Information System (INIS)

    Tanaka, Aya; Minami, Nodoka; Mukai, Takahiro; Yasuoka, Yumi; Iimoto, Takeshi; Omori, Yasutaka; Nagahama, Hiroyuki; Muto, Jun

    2017-01-01

    AlphaGUARD is a low-effective volume detector and one of the most popular portable radon monitors which is currently available. This study investigated whether AlphaGUARD can accurately measure the variable indoor radon levels. The consistency of the radon-concentration data obtained by AlphaGUARD is evaluated against simultaneous measurements by two other monitors (each ∼10 times more sensitive than AlphaGUARD). When accurately measuring radon concentration with AlphaGUARD, we found that the net counts of the AlphaGUARD were required of at least 500 counts, <25% of the relative percent difference. AlphaGUARD can provide accurate measurements of radon concentration for the world average level (∼50 Bq m -3 ) and the reference level of workplace (1000 Bq m -3 ), using integrated data over at least 3 h and 10 min, respectively. (authors)

  3. Radon measurement waters from different regions of Transylvania

    International Nuclear Information System (INIS)

    Moldovan, M.; Cosma, C.

    2004-01-01

    . There was a difference between the value of k used by Jiri Plch (k = 8) and the value of k that we have used (k = 10) because we measured radon concentration of the samples immediately after stirring and not after 15 minutes, like Plch. The variation domain of our measurements goes from 1 Bq/l to 38 Bq/l, their plot indicating a log-normal distribution. The geometric mean of this log-normal distribution, GM = 8.545 Bq/l, is lower than the same value of the domestic water supplies from Iran (10-20 Bq/l) but comparable with that for the South -Central Texas Water supplies (5 - 8 Bq/l). The average value obtained in different regions is: 14.32 Bq/l for Sibiu with 42 samples, 2.38 Bq/l for Harghita with 5 samples; 6.45 Bq/l for Covasna with 36 samples; 7.34 Bq/l for Bihor with 5 samples; 9.38 for Arad with 9 samples; 6.83 Bq/l for Aries Valley with 19 samples, 11.8 Bq/l Transylvania plateau with 24 samples. Some of our values are higher than EPA proposed drinking water standard of 300 pCi/l (11 Bq/l). We have also put under observation one of the springs in order to find out the temporal fluctuations of radon concentration both in summertime and wintertime and we concluded that rainfalls are an important factor which influences the 222 Rn content. (authors)

  4. Instrumentation for a radon research house

    International Nuclear Information System (INIS)

    Nazaroff, W.W.; Revzan, K.L.; Robb, A.W.

    1981-07-01

    A highly automated monitoring and control system for studying radon and radon-daughter behavior in residences has been designed and built. The system has been installed in a research house, a test space contained in a two-story wood-framed building, which allows us to conduct controlled studies of (1) pollutant transport within and between rooms, (2) the dynamics of radon daughter behavior, and (3) techniques for controlling radon and radon daughters. The system's instrumentation is capable of measuring air-exchange rate, four-point radon concentration, individual radon daughter concentrations, indoor temerature and humidity, and outdoor weather parameters (temperature, humidity, modules, wind speed, and wind direction). It is also equipped with modules that control the injection of radon and tracer gas into the test space, the operation of the forced-air furnace, the mechanical ventilation system, and the mixing fans located in each room. A microcomputer controls the experiments and records the data on magnetic tape and on a printing terminal. The data on tape is transferred to a larger computer system for reduction and analysis. In this paper we describe the essential design and function of the instrumentation system, as a whole, singling out those components that measure ventilation rate, radon concentration, and radon daughter concentrations

  5. Indoor radon pollution: Control and mitigation. June 1978-December 1989 (Citations from the NTIS data base). Report for June 1978-December 1989

    International Nuclear Information System (INIS)

    1990-01-01

    This bibliography contains citations concerning the control and mitigation of radon pollution in homes and commercial buildings. Citations cover radon transport studies in buildings and soils, remedial action proposals on contaminated buildings, soil venting, building ventilation, sealants, filtration systems, water degassing, reduction of radon sources in building materials, and evaluation of existing radon mitigation programs including their cost effectiveness. Analysis and detection of radon and radon toxicity are covered in separate published bibliographies. (Contains 129 citations fully indexed and including a title list.)

  6. Radon in Croatian spas

    International Nuclear Information System (INIS)

    Radolic, V.; Vukovic, B.; Planinic, J.

    2004-01-01

    There are ten thermal spas in Croatia and all of them provide health services for patients and visitors. Radon measurements were performed since there is a lack of data concerning natural radioactivity originated from radon and its short-lived progenies in such environments. The thermal water at two different sites (the indoor swimming pool with geothermal water and the spring) in each spa was sampled and radon concentrations were measured by AlphaGUARD radon measuring system. The obtained values were in the range of 0.7 to 19 Bq.dm -3 and 2 to 94 Bq.dm -3 for indoor swimming pools and springs, respectively. Integrated measurements of radon concentration in air were performed by two solid state nuclear track detectors LR-115 II (open and diffusion one) thus enabling estimation of equilibrium factor between radon and its daughters. The annual effective doses received by spa workers were found to be about 1 mSv/y (below the lower limit value of 3 mSv/y recommended by ICRP 65). The doses of patients and visitors were one or two order of magnitude lower than that of the personnel. (author)

  7. Chemical properties of radon

    International Nuclear Information System (INIS)

    Stein, L.

    1986-01-01

    Radon is frequently regarded as a totally inert element. It is, however, a ''metalloid'' - an element which lies on the diagonal of the Periodic Table between the true metals and nonmetals and which exhibits some of the characteristics of both. It reacts with fluorine, halogen fluorides, dioxygenyl salts, fluoro-nitrogen salts, and halogen fluoride-metal fluoride complexes to form ionic compounds. Several of the solid reagents can be used to collect radon from air but must be protected from moisture, since they hydrolyze readily. Recently, solutions of nonvolatile, cationic radon have been produced in nonaqueous solvents. Ion-exchange studies have shown that the radon can be quantitatively collected on columns packed with either Nafion resins or complex salts. In its ionic state, radon is able to displace H + , Na + , K + , Cs + , Ca 2+ , and Ba 2+ ions from a number of solid materials. 27 refs., 6 figs

  8. The radon: evaluation and risk management; Le radon: evaluation et gestion du risque

    Energy Technology Data Exchange (ETDEWEB)

    Lacoste, A.C. [Direction Generale de la Surete Nucleaire et de la Radioprotection, 75 - Paris (France); Masse, R. [Academie des Technologies, 75 - Paris (France); Aurengo, A. [Hopital Pitie-Salpetriere, Service de Medecine Nucleaire, 75 - Paris (France); Erich Wichmann, H. [Neuberberg Munich Univ. (Germany); Timarche, M.; Laurier, D.; Robe, M.Ch. [Institut de Radioprotection et de Surete Nucleaire (IRSN), 92 - Clamart (France); Baubron, J.C.; Bonijoly, D. [BRGM, 75 - Paris (France); Collignan, B. [Centre Scientifique et Technique du Batiment, (CSTB), 75 - Paris (France); Berrier, H. [Direction Gle de l' Urbanisme de l' Habitat et de la Construction, 75 - Paris (France); Jaouen, J. [Direction Departementale des Affaires Sanitaires et Sociales de la Haute-Vienne (France); Caamano, D. [Direction Departementale des Affaires Sanitaires et Sociales de l' Essonne, 91 (France); Guiot, F. [Direction Departementale des Affaires Sanitaires et Sociales de la Haute-Marne (France); Grall, B. [Direction Departementale des Affaires Sanitaires et Sociales de Bretagne (France); Frutos Vasquez, B.; Olaya Adan, M. [Istituto de Ciencias de la Construction (Italy); Garcia Cadierno, J.P.; Martin Matarranz, J.L.; Serrano Renedo, J.; Suarez Mahou, E. [Consejo de Seguridad Nuclear, Madrid (Spain); Fernandez, J.A. [ENUSA Industrias Avanzadas (Spain); Mjones, L.; Pirard, P. [Institut de veille sanitaire, 94415 - Saint-Maurice (France); Godet, J.L.; Rougy, Ch. [Direction Gle de la Surete Nucleaire et de la Radioprotection, 75 - Paris (France)

    2003-06-15

    The radon exposure constitutes for the French population the first cause of natural irradiation among the different natural sources of irradiation. It is possible to have a significant action on it, either by making draught proof in order to avoid to radon to get inside houses, either by ventilating in order to dispel the radon and improve air quality. (N.C.)

  9. Radon in large buildings

    International Nuclear Information System (INIS)

    Wilson, D.L.; Dudney, C.S.; Gammage, R.B.

    1993-01-01

    Over the past several years, considerable research has been devoted by the U.S. Environmental Protection Agency (USEPA) and others to develop radon sampling protocols for single family residences and schools. However, very little research has been performed on measuring radon in the work place. To evaluate possible sampling protocols, 833 buildings throughout the United States were selected for extensive radon testing. The buildings tested (warehouses, production plants and office buildings) were representative of commercial buildings across the country both in design, size and use. Based on the results, preliminary radon sampling protocols for the work place have been developed. (orig.). (5 refs., 3 figs.)

  10. Radon dose and aerosols

    International Nuclear Information System (INIS)

    Planinic, J.; Radolic, V.; Faj, Z.; Vukovic, B.

    2000-01-01

    The equilibrium factor value (F) was measured in the NRPB radon chamber and the corresponding track density ratio (r = D/D 0 ) of bare (D) and diffusion (D 0 ) LR-115 nuclear track detectors was determined, as well as the regression equation F(r). Experiments with LR-115 nuclear track detectors and aerosol sources (burning candle and cigarette) were carried out in the Osijek University radon chamber and afterwards an empirical relationship between the equilibrium factor and aerosol concentration was derived. For the purpose of radon dose equivalent assessment, procedures for determining the unattached fraction of radon progeny were introduced using two nuclear track detectors. (author)

  11. Radon remediation of a two-storey UK dwelling by active sub-slab depressurization: observations on hourly Radon concentration variations

    International Nuclear Information System (INIS)

    Denman, A.R.

    2008-01-01

    Radon concentration levels in a two-storey detached single-family dwelling in Northamptonshire, UK, were monitored at hourly intervals throughout a 5-week period during which sub-slab depressurization remediation measures, including an active sump system, were installed. Remediation of the property was accomplished successfully, with the mean radon levels upstairs and downstairs greatly reduced and the prominent diurnal variability in radon levels present prior to remediation almost completely removed. Following remediation, upstairs and downstairs radon concentrations were 32% and 16% of their pre-remediation values respectively. The mean downstairs radon concentration was lower than that upstairs, with pre-and post-remediation values of the upstairs/downstairs concentration ratio, R U/D , of 0.93 and 1.76 respectively. Cross-correlation between upstairs and downstairs radon concentration time-series indicates a time-lag of the order of 1 hour or less, suggesting that diffusion of soil-derived radon from downstairs to upstairs either occurs within that time frame or forms a relatively insignificant contribution to the upstairs radon level. Cross-correlation between radon concentration time-series and the corresponding time-series for local atmospheric parameters demonstrated correlation between radon concentrations and internal/external pressure-difference prior to remediation. This correlation disappears following remediation, confirming the effectiveness of the remediation procedure in mitigating radon ingress from the ground via the stack-effect. Overall, these observations provide further evidence that radon emanation from building materials makes a not insignificant contribution to radon concentration levels within the building. Furthermore, since this component remains essentially unaffected by sub-slab depressurization, its proportional contribution to the total radon levels in the home increases following remediation, leading to the conclusion that where

  12. Radon and radon-daughter concentrations in air in the vicinity of the Anaconda Uranium Mill

    Energy Technology Data Exchange (ETDEWEB)

    Momeni, M H; Lindstrom, J B; Dungey, C E; Kisieleski, W E

    1979-11-01

    Radon concentration, working level, and meteorological variables were measured continuously from June 1977 through June 1978 at three stations in the vicinity of the Anaconda Uranium Mill with measurements integrated to hourly intervals. Both radon and daughters show strong variations associated with low wind velocities and stable atmospheric conditions, and diurnal variations associated with thermal inversions. Average radon concentration shows seasonal dependence with highest concentrations observed during fall and winter. Comparison of radon concentrations and working levels between three stations shows strong dependence on wind direction and velocity. Radon concentrations and working-level distributions for each month and each station were analyzed. The average maximum, minimum, and modal concentration and working levels were estimated with observed frequencies. The highest concentration is 11,000 pCi/m/sup 3/ on the tailings. Working-level variations parallel radon variations but lag by less than one hour. The highest working levels were observed at night when conditions of higher secular radioactive equilibrium for radon daughters exist. Background radon concentration was measured at two stations, each located about 25 km from the mill, and the average is 408 pCi/m/sup 3/. Average working-level background is 3.6 x 10/sup -3/.

  13. An investigation into the knowledge and attitudes towards radon testing among residents in a high radon area

    International Nuclear Information System (INIS)

    Clifford, Susan; Menezes, Gerard; Hevey, David

    2012-01-01

    The aim of this study was to investigate the knowledge and attitudes of residents in the Castleisland area to radon. Castleisland in Co. Kerry was described as a high radon area following the discovery of a house in the area with radon levels 245 times that of the national reference level. Residents in this area were then asked to measure their homes for radon in the Castleisland radon survey. The uptake of this measurement was 17%. In order to investigate this response rate further, a questionnaire was designed and distributed to residents in the Castleisland area. This questionnaire measured the testing history of the participants, the reasons for testing/not testing, the factors important to them when considering having their home tested, radon knowledge and finally intentions to measure their home for radon. It was found that the main reason people do not test their home for radon is that they believe their home does not have a problem. Optimistic bias was thought to play a role here. The subjective norm component of the theory of planned behaviour was found to have a significant independent contribution in the variation in intentions to measure one’s home for radon and this in turn could be targeted to increase uptake of radon measurement in the future. (note)

  14. Radon in dwellings the national radon survey Clare, Limerick and Tipperary

    International Nuclear Information System (INIS)

    McGarry, A.T.; Fennell, S.G.; Mackin, G.M.; Madden, J.S.; O'Colmain, M.

    1998-12-01

    This report presents the results of the fourth phase of the National Radon Survey carried out by the Radiological Protection Institute of Ireland. The counties included in this phase are Clare, Limerick and Tipperary. The average radon concentrations for the houses measured in these counties were 88 Bq/m 3 , 77 Bq/m 3 and 79 Bq/m 3 . The measurement data were grouped on the basis of the 10 km grid squares of the Irish National Grid System and used to predict the percentage of dwellings in each grid square which exceeds the Reference Level of 200 Bq/m 3 . Grid squares where this percentage is predicted to be 10% or higher are designated High Radon Areas. The health effects of exposure to high radon levels are discussed and recommendations are made regarding both new and existing dwellings. (author)

  15. Environmental Concentration of Radon and Radon Progeny in a Nuclear Facility in a Decommissioning Stage

    International Nuclear Information System (INIS)

    Ramirez, M. P.; Correa, E.; Sancho, C.

    1999-01-01

    According to the new European Directive 96/29/EURATOM the radiological risk due to natural radionuclides must be consider and the pertinent periodic control must be realized. During the works performed at CIEMAT an estimation of the effective average doses due to Radon inhalation in work places of the installation have been performed. Radon and Radon progeny concentration has been measured in continuous joint whit the meteorological conditions as temperature, pressure and relative humidity. Two different equipment has been used: Alpha-guard whit ionization chamber detector and Eda-wlm-300 whit a semiconductor detector. A passive Radon detector, E-perm has been simultaneously used in the monitoring system. The results obtained during the measuring of Radon and Radon progeny concentrations indoors and estimation of doses have been analyzed and are presented in the paper. (Author) 11 refs

  16. Radon remediation in irish schools

    International Nuclear Information System (INIS)

    Synnott, H.

    2006-01-01

    Full text: Commencing in 1998, the Radiological Protection Institute of Ireland carried out radon measurements in 3826 schools in the Republic of I reland on behalf of the Irish Department of Education and Science (D.E.S.). This represents approximately 97% of all schools in the country. Approximately 25% (984) schools had radon concentrations above the Irish national schools Reference Level for radon of 200 Bq/m 3 and required remedial work. The number of individual rooms with radon concentrations above 200 Bq/m 3 was 3020. Remedial work in schools commenced in early 2000. In general schools with maximum radon concentrations in the range 200 -400 Bq/m 3 in one or more rooms were remediated through the installation of passive systems such as an increase in permanent background ventilation mainly wall vents and trickle vents in windows. Schools with maximum radon concentrations greater than 400 Bq/m 3 were usually remediated through the provision of active systems mainly fan assisted sub -slab de pressurization or where this was not possible fan assisted under floor ventilation. The cost of the remedial programme was funded by central Government. Active systems were installed by specialized remedial contractors working to the specifications of a radon remedial expert appointed by the D.E.S. to design remedial systems for affected schools. Schools requiring increased ventilation were granted aided 190 pounds per affected room and had to organize the work themselves. In most schools radon remediation was successful in reducing existing radon concentrations to below the Reference Level. Average radon concentration reduction factors for sub-slab de pressurization systems and fan assisted fan assisted under floor ventilation ranged from 5 to 40 with greater reduction rates found at higher original radon concentrations. Increasing ventilation in locations with moderately elevated radon concentrations (200 - 400 Bq/m 3 ) while not as effective as active systems produced on

  17. An Alpha spectrometer for measuring radon daughter individual activity concentration

    International Nuclear Information System (INIS)

    Berico, M.; Formignani, M.; Mariotti, F.

    2001-01-01

    In the frame of the program of the Institute for Radiation Protection of ENEA, related to the evaluation of dose from radon and thoron progeny, an alpha spectrometer for the continuous air monitoring (CAM type) of radon and thoron has been realized. The constructive characteristics of the device are here presented together with energy and efficiency calibration. The device allows, by means of a screen type diffusion battery and a filter, to determinate the single radioactivity of each radionuclide of the progeny selecting them in relation to their diffusive behaviour (dichotomous particle size selection). The three-count filter method has been employed to measure the concentrations of 218 Po, 214 Pb and 214 Bi in air. Radon and thoron effective doses using a dosimetric, instead of an epidemiologic approach, will be then evaluated [it

  18. Radon transport modelling: User's guide to RnMod3d

    International Nuclear Information System (INIS)

    Andersen, C.E.

    2000-08-01

    RnMod3d is a numerical computer model of soil-gas and radon transport in porous media. It can be used, for example, to study radon entry from soil into houses in response to indoor-outdoor pressure differences or changes in atmospheric pressure. It can also be used for flux calculations of radon from the soil surface or to model radon exhalation from building materials such as concrete. The finite-volume model is a technical research tool, and it cannot be used meaningfully without good understanding of the involved physical equations. Some understanding of numerical mathematics and the programming language Pascal is also required. Originally, the code was developed for internal use at Risoe only. With this guide, however, it should be possible for others to use the model. Three-dimensional steady-state or transient problems with Darcy flow of soil gas and combined generation, radioactive decay, diffusion and advection of radon can be solved. Moisture is included in the model, and partitioning of radon between air, water and soil grains (adsorption) is taken into account. Most parameters can change in time and space, and transport parameters (diffusivity and permeability) may be anisotropic. This guide includes benchmark tests based on simple problems with known solutions. RnMod3d has also been part of an international model intercomparison exercise based on more complicated problems without known solutions. All tests show that RnMod3d gives results of good quality. (au)

  19. Preventing excessive radon exposure in U.K. housing

    International Nuclear Information System (INIS)

    Miles, J.C.H.; Cliff, K.D.; Green, B.M.R.; Dixon, D.W.

    1992-01-01

    In the United Kingdom (UK) it has been recognized for some years that some members of the population received excessive radiation exposure in their homes from radon and its decay products. To prevent such exposures, an Action Level of 400 Bq m -3 was adopted in 1987. In January, 1990, the National Radiological Protection Board (NRPB) advised that the Action Level should be reduced to 200 Bq m -3 , and this advice was accepted by the Government. It is estimated that exposures in up to 100,000 UK homes exceed this Action Level; this amounts to about 0.5% of the available housing. The UK authorities have developed a strategy for preventing such exposures: (1) Areas in which it is estimated that >1% of homes exceed the Action Level for radon are being designated as Affected Areas, and a program to map such areas is under way. Households in these areas are advised to have radon measurements made by NRPB under a open-quotes freeclose quotes (Government-funded) scheme. (2) Householders found to have whole-house, whole-year average radon concentrations >200 Bq m -3 are advised to take remedial action and are provided with information on how this can be done. Partial grants toward remedial work are available in cases of financial need. So far, around 3000 such households have been identified. (3) Within Affected Areas, localities are being defined where new homes must incorporate precautions against radon exposure. In addition to this strategy, a joint case-control study of the risks of radon in homes is being undertaken by the Imperial Cancer Research Fund and NRPB, supported by the UK Government and the Commission of the European Communities

  20. Radon classification of building ground

    International Nuclear Information System (INIS)

    Slunga, E.

    1988-01-01

    The Laboratories of Building Technology and Soil Mechanics and Foundation Engineering at the Helsinki University of Technology in cooperation with The Ministry of the Environment have proposed a radon classification for building ground. The proposed classification is based on the radon concentration in soil pores and on the permeability of the foundation soil. The classification includes four radon classes: negligible, normal, high and very high. Depending on the radon class the radon-technical solution for structures is chosen. It is proposed that the classification be done in general terms in connection with the site investigations for the planning of land use and in more detail in connection with the site investigations for an individual house. (author)

  1. Investigation of radon level in Chongqing

    International Nuclear Information System (INIS)

    Pan Chunzhen; Liu Jialie; Du Hengyan; Wang Ling; Li Yiwei

    2009-01-01

    Contents of radon in air in the urban district, building fields,diggings and hotel in Chongqing were investigated. Result shows that the mean concentration of radon is 10.8 Bq/m 3 in air in the urban district, and the mean concentration of radon is 1193 Bq/m 3 in soils on building fields. Radon level is obviously different in each of diggings, with the highest being in fluorite mine and the second in plumbum and zinc mine. The statistical mean value of radon concentration of 10 typles of diggings investigated is 65.2 Bq/m 3 , while the mean concentration of radon in fluorite mine is 369 Bq/m 3 , which is 35 times higher than in the urban area. The mean concentration of radon is 32.9 Bq/m 3 in eight hotels. (authors)

  2. Paloma-radon: atmospheric radon 222 as a geochemical probe for water in the martian subsoil

    International Nuclear Information System (INIS)

    Sabroux, J.Ch.; Michielsen, N.; Voisin, V.

    2003-01-01

    Radon exhalation from a porous soil is known to depend strongly on the soil moisture content: a minute amount of water, or water ice, in the pore space increases dramatically the possibility for radon to migrate far from its parent mineral. We propose to take advantage of this characteristic by using atmospheric radon 222 as a geochemical probe for water in the Martian soil, at least one order of magnitude deeper than the current Mars Odyssey neutron data. Strong thermal inversions during the Martian night will accumulate radon in the lowest atmospheric boundary layer, up to measurable levels despite the comparatively high environmental (cosmic and solar) background radiation and the assumed low uranium content of the upper crust of the planet. Preliminary studies and development of an instrument for the measurement of the Martian atmospheric alpha radioactivity is part of the CNES supported PALOMA experiment. Two test benches have been implemented, one of them allowing differential measurements of the diffusion of radon in the Martian soil simulant NASA JSC Mars-1, under relevant temperatures and pressures. The other, a 1 m3 radon-dedicated test bench, aims to characterize the instrument that will measure radon in the Mars environment (7 mb CO 2 ). Tests on several nuclear radiation detectors show that semiconductor alpha-particle detectors (PIPS) are the best option. In addition, the detection volume is left open in order to capitalize upon the long (ca. 4 m) alpha track at this low pressure. A stationary diffusion model was developed in order to assess the radon flux at the Mars soil surface. Diffusion of gas in Martian soil is governed by Knudsen diffusion. The radon Knudsen diffusion coefficient was estimated, depending on the soil moisture and relevant structural properties, leading to a radon diffusion length of the order of 20 m. The landed platform PALOMA-Radon instrument will consist of a set of alpha detectors connected to an electronic spectrometer, a

  3. Paloma-radon: atmospheric radon 222 as a geochemical probe for water in the martian subsoil

    Energy Technology Data Exchange (ETDEWEB)

    Sabroux, J.Ch.; Michielsen, N.; Voisin, V

    2003-07-01

    Radon exhalation from a porous soil is known to depend strongly on the soil moisture content: a minute amount of water, or water ice, in the pore space increases dramatically the possibility for radon to migrate far from its parent mineral. We propose to take advantage of this characteristic by using atmospheric radon 222 as a geochemical probe for water in the Martian soil, at least one order of magnitude deeper than the current Mars Odyssey neutron data. Strong thermal inversions during the Martian night will accumulate radon in the lowest atmospheric boundary layer, up to measurable levels despite the comparatively high environmental (cosmic and solar) background radiation and the assumed low uranium content of the upper crust of the planet. Preliminary studies and development of an instrument for the measurement of the Martian atmospheric alpha radioactivity is part of the CNES supported PALOMA experiment. Two test benches have been implemented, one of them allowing differential measurements of the diffusion of radon in the Martian soil simulant NASA JSC Mars-1, under relevant temperatures and pressures. The other, a 1 m3 radon-dedicated test bench, aims to characterize the instrument that will measure radon in the Mars environment (7 mb CO{sub 2}). Tests on several nuclear radiation detectors show that semiconductor alpha-particle detectors (PIPS) are the best option. In addition, the detection volume is left open in order to capitalize upon the long (ca. 4 m) alpha track at this low pressure. A stationary diffusion model was developed in order to assess the radon flux at the Mars soil surface. Diffusion of gas in Martian soil is governed by Knudsen diffusion. The radon Knudsen diffusion coefficient was estimated, depending on the soil moisture and relevant structural properties, leading to a radon diffusion length of the order of 20 m. The landed platform PALOMA-Radon instrument will consist of a set of alpha detectors connected to an electronic spectrometer

  4. Radon Concentration in Caves of Croatia - Assesing Effective Radon Doses for Occupational Workers and Visitors

    International Nuclear Information System (INIS)

    Radolic, V.; Miklavcic, I.; Poje, M.; Stanic, D.; Vukovic, B.; Paar, D.

    2011-01-01

    Radon monitoring at potentially highly radioactive location such as caves is important to assess the radiological hazards to occupational workers and occasional visitors. In its Publication 65 the ICRP has produced recommendations dealing with exposure to elevated background radiation, in particular, the risk associated with the inhalation of radon and radon progeny. Recommended annual effective dose from radon 222Rn and its short-lived progeny for workers should not exceed 20 mSv and for occasional users (visitors) the same recommendation is 1 mSv. Measurements were performed with series of track etched detectors (LR115 - type II) in several caves in Croatia. The obtained values for the radon concentration ranged from ambient values up to several thousand Bq m -3 . Radon concentration was measured in about 20 caves of Velebit and Zumberak mountains and the highest radon concentration was in Lubuska jama (3.8 kBq m -3 ) and cave Dolaca (21.8 kBq m -3 ), respectively. Djurovica cave is especially interesting because of its huge tourist potential due to its location bellow Dubrovnik airport. Its mean annual radon concentration of 17.6 kBq m -3 classifies Djurovica cave among caves with high radon concentration. A visitor during half an hour visit at summer time would receive an effective dose of 30.6 μSv. Calculated mean dose rate of 44 μSv/h means that workers (mainly tourist guides) should limit their time inside cave to 454 hours per year. Manita pec is the only cave open for tourists on the territory of Paklenica National Park. The preliminary radon measurements performed during summer 2010, gave an average radon concentration of 1.1 kBq m -3 . An exposure to average dose rate of 3.7 μSv/h means that the tourist guides would receive an effective dose of 0.42 mSv during summer period according to their working schedule. A visitor during half an hour visits would receive an effective dose of 1.86 μSv. (author)

  5. Assessing the effectiveness of slab flooring as a barrier to soil gas and radon infiltration

    International Nuclear Information System (INIS)

    Williamson, A.D.; Fowler, C.S.; McDonough, S.E.

    1995-01-01

    Experimental studies on the entry of soil gas and radon into slab-on-grade buildings have been carried out in instrumented, single-zone test structures. This work, as part of the Florida Radon Research Program, focused on the effectiveness of slab flooring variants as barriers to soil gas/radon entry. A second objective was the study of the role of subslab fill soil as both a potential source of and barrier to radon entry. Studies were made in well-sealed (∼ 600 mm 2 ELA) unoccupied test buildings placed on well-characterized, radium-bearing sandy fill soil. The buildings were instrumented with data acquisition systems to continuously monitor indoor radon concentrations, differential pressures at several subsurface locations, weather conditions, and soil moisture. The response of the structures to mechanical depressurization as well as natural driving forces was measured. Limited measurements were made regarding direct diffusive transport of radon through apparently intact concrete slabs, as well as transport through cracks in the floor structure

  6. Measurement of the radon exhalation rate from the medium surface by tracing the radon concentration

    International Nuclear Information System (INIS)

    Yanliang Tan; Detao Xiao

    2013-01-01

    The paper will present a method based on the accumulation chamber technique for measuring of radon exhalation from the medium surface. A radon monitor traces the change of radon concentration in the accumulation chamber, and then the radon exhalation can be obtained accurately through linear fit. Based on our recent experiments, the radon exhalation rate from the medium surface obtained from this method is in good agreement with the actual exhalation rate of our simulation facility. This method is superior to the competition method which obtains the radon exhalation through the exponential fit by an external PC-system. The calculation for the exponential fit is very easy by computer and related software. However, for portable instruments, the single chip microcomputer can't calculate the exponential fit rapidly. Thus, this method is usable for developing the new portable instrument to classify building materials, etc. (author)

  7. Radon emanometry in active volcanoes

    Energy Technology Data Exchange (ETDEWEB)

    Seidel, J.L.; Monnin, M. (CNRS, IN2P3, BP45/F63170 Aubiere (France)); Cejudo, J. (Instituto Nacional de Investigaciones Nucleares, Mexico City)

    1984-01-01

    Radon emission measurements from active volcanoes has, since 1981, been continuously measured at monitoring stations in Mexico and in Costa Rica. Counting of etched alpha tracks on cellulose nitrate LR-115 detectors give varying results at the several stations. Radon emanation at Chichon, where an explosive eruption occurred in 1982, fell down. Radon detection at the active volcano in Colima shows a pattern of very low emission. At the Costa Rica stations located at Poas, Arenal and Irazu, the radon emanation shows regularity.

  8. Radon risk in residential buildings

    International Nuclear Information System (INIS)

    Niewiadomski, T.

    1996-01-01

    The author discusses the risk related to the inhalation of radon decay products. This products are the cause of almost the half of the doses absorbed by the people. The concentration of radon in buildings is much higher than in the open areas and its country average in Poland is 50 Bq/m 3 . It is difficult to predict the concentration of radon in the building without measurement. Author concludes that there are technical means to decrease radon concentration in buildings

  9. An investigation of radon mitigation in Pennsylvania

    International Nuclear Information System (INIS)

    Belanger, W.E.

    1990-01-01

    This paper reports that Radon mitigation contractors were contacted to obtain information on the progress of radon mitigation in Pennsylvania. Information was obtained on the beginning and ending radon concentrations, the cost of the job, the mitigation method used, and the location by zip code. Most radon mitigations achieved reductions below 90 percent, and most achieved 4 pCi/1. 65 percent achieved 2 pCi/1. There was little relationship between the cost of the job and either the percent reduction or the beginning radon. Percent reduction was strongly related to beginning radon, with lower percent reductions associated with low starting radon

  10. Effect of natural ventilation on radon and radon progeny levels in houses. Rept. for Apr 90-Sep 91

    International Nuclear Information System (INIS)

    Cavallo, A.; Gadsby, K.; Reddy, T.A.; Socolow, R.

    1991-01-01

    The paper discusses the effect of natural ventilation on radon and radon progeny levels in houses. Contradicting the widely held assumption that ventilation is ineffective in reducing indoor radon concentrations, experiments in a research house have shown that the basement radon level can be reduced by a factor of 5 to 10 using only natural ventilation. Measurement of the outdoor-basement pressure differential and the radon entry rate shows that this unexpectedly large reduction in indoor radon levels is caused by two complementary physical processes: (1) the obvious one, dilution, which lowers radon concentrations by adding uncontaminated outdoor air; and (2) although less evident, introducing a pressure break in the system through an open basement window which, in turn, reduces the outdoor-basement pressure differential and the rate at which radon-laden soil gas is drawn into the house. The radon entry rate was found to be a linear function of basement depressurization up to a differential pressure of about 4 Pa, as would be expected for laminar soil gas flow; opening two basement windows approximately doubled the building air exchange rate and reduced the radon entry rate by up to a factor of 5

  11. Uranium City radiation reduction program: further studies on remedial measures and radon infiltration routes for houses with block walls

    International Nuclear Information System (INIS)

    Leung, M.K.

    1980-01-01

    This report describes the results of tests of partial sealing of concrete block walls to prevent radon infiltration into houses in Uranium City, and gives the results of studies of radon migration through concrete block walls. Results of some laboratory tests on the effectiveness of concrete blocks as a radon barrier are included

  12. A perspective on risks from radon

    International Nuclear Information System (INIS)

    Higson, D. J.

    2010-10-01

    In its Statement on Radon (November 2009), the International Commission on Radiological Protection (ICRP) has reduced the upper reference level for radon gas in dwellings to 300 Bq m -3 . The recommended level for workplaces is 1000 Bq m -3 . A risk coefficient of 8 x 10 -10 per Bq h m -3 is recommended without reference to smoking habits. On the basis of these figures: 1) The estimated risk of fatal cancer from exposure to radon at home and at work could be greater than the observed risk of accidental death from travelling by car, which would be surprising if true. 2) The estimated risk of lung cancer from radon could be greater than the observed risk of lung cancer from all causes, which is actually known to be dominated by smoking. The author is not aware of any direct evidence of risks from inhaling radon in Australian dwellings, 99% of which have radon levels below 50 Bq m -3 . Evidence available from other countries shows that: 1) The effects of radon in the incidences of lung cancer are uncertain at levels less then about 50-100 Bq m -3 . 2) The estimation of risks at levels below 200 Bq m -3 depends on extrapolation from risks observed at higher levels. 3) Risks to non-smokers from radon are 25 times less than risks to smokers. Its concluded that the ICRP Statement on Radon and radon policies in the US and UK have the potential to cause unwarranted concern. Some people may be made to feel they need to spend money modifying their homes and workplaces to protect occupants from exposure to radon when there is no compelling reason to show that this is necessary. The vast majority of non-smokers do not need to be protected from radon. (Author)

  13. A perspective on risks from radon

    International Nuclear Information System (INIS)

    Higson, D.J.

    2011-01-01

    In its Statement on Radon (November 2009), the ICRP has reduced the upper reference level for radon gas in dwellings to 300 Bq m -3 . The recommended level for workplaces is 1000 Bq m -3 . A risk coefficient of 8x10 -10 per Bq h m is recommended without reference to smoking habits. On the basis of these figures,the estimated risk of fatal cancer from exposure to radon at home and at work could be greater than the observed risk of accidental death from travelling by car, which would be surprising if true. Also the estimated risk of lung cancer from radon could be greater than the observed risk of lung cancer from all causes, which is actually known to be dominated by smoking. The author is not aware of any direct evidence of risks from inhaling radon in Australian dwellings, 99% of which have radon levels below 50 Bq m -3 . Evidence available from other countries shows that: effects on the incidences of lung cancer are uncertain at radon levels below 100 Bq m -3 ; the estimation of risks at levels below 200 Bq m -3 depends on extrapolation from risks observed at higher levels, and risks to non-smokers from radon are 25 times less than risks to smokers. It is concluded that the ICRP Statement on Radon and radon policies in the US and UK have the potential to cause unwarranted concern. Some people may be made to feel they need to spend money modifying their homes and workplaces to protect occupants from exposure to radon when there is no compelling reason to show that this is necessary. The vast majority of non-smokers do not need to be protected from radon.

  14. A perspective on risks from radon

    Energy Technology Data Exchange (ETDEWEB)

    Higson, D. J., E-mail: higsond@bigpond.net.a [Australasian Radiation Protection Society, PO Box 7108, Upper Ferntree Gully, Victoria 3156 (Australia)

    2010-10-15

    In its Statement on Radon (November 2009), the International Commission on Radiological Protection (ICRP) has reduced the upper reference level for radon gas in dwellings to 300 Bq m{sup -3}. The recommended level for workplaces is 1000 Bq m{sup -3}. A risk coefficient of 8 x 10{sup -10} per Bq h m{sup -3} is recommended without reference to smoking habits. On the basis of these figures: 1) The estimated risk of fatal cancer from exposure to radon at home and at work could be greater than the observed risk of accidental death from travelling by car, which would be surprising if true. 2) The estimated risk of lung cancer from radon could be greater than the observed risk of lung cancer from all causes, which is actually known to be dominated by smoking. The author is not aware of any direct evidence of risks from inhaling radon in Australian dwellings, 99% of which have radon levels below 50 Bq m{sup -3}. Evidence available from other countries shows that: 1) The effects of radon in the incidences of lung cancer are uncertain at levels less then about 50-100 Bq m{sup -3}. 2) The estimation of risks at levels below 200 Bq m{sup -3} depends on extrapolation from risks observed at higher levels. 3) Risks to non-smokers from radon are 25 times less than risks to smokers. Its concluded that the ICRP Statement on Radon and radon policies in the US and UK have the potential to cause unwarranted concern. Some people may be made to feel they need to spend money modifying their homes and workplaces to protect occupants from exposure to radon when there is no compelling reason to show that this is necessary. The vast majority of non-smokers do not need to be protected from radon. (Author)

  15. Discussion on the source of radon in uranium exploration method using radon-released thermal effect in minerals

    International Nuclear Information System (INIS)

    Su Shoutian.

    1985-01-01

    This paper considers the problem of the source of radon in uranium exploration method using radon-released thermal effect. In minerals by means of scintillation emanometry, we have carried out the measurement on radon content in minerals at various temperature in barren and ore-bearing granites of the granite-type uranium deposit No. 752, and inclusion decrepitation method has also been used to determine the temperature of decrepitation and its relative frequency. It was found from experiments that heated samples may release most of radon prior to inclusion decrepitation, radon released from thermal effect was, on the contrary, very little at temperature intervals of inclusion decrepitation on a large scale basis. When inclusions were ground after radon releasing, it would still release from inclusions after reheating. The radon content calculated from uranium content in inclusions is lower than the sensitivity of the determination method, so it is too difficult to be determined, indicating that the radon content released is not related to inclusions. Samples were determined by uranium chemical analysis and radium radiochemical analysis and it is obvious to note that the radon content released from thermal effect in minerals is positively correlated to the uranium and radium content. Various kinds of experiments suggest that radon is not derived from inclusions but from the whole mineral

  16. 77 FR 46089 - Agency Information Collection Activities; Proposed Collection; Comment Request; EPA's ENERGY STAR...

    Science.gov (United States)

    2012-08-02

    ... Activities; Proposed Collection; Comment Request; EPA's ENERGY STAR Program in the Commercial and Industrial... this action are participants in EPA's ENERGY STAR Program in the Commercial and Industrial Sectors. Title: Information Collection Activities Associated with EPA's ENERGY STAR Program in the Commercial and...

  17. Second workshop on radon and radon daughters in urban communities associated with uranium mining and processing

    International Nuclear Information System (INIS)

    1979-01-01

    A second meeting of Atomic Energy Control Board staff, federal and provincial government representatives, and consultants was held to discuss progress in reducing the concentrations of radon and its daughter products in houses in communities like Bancroft, Elliot Lake, Port Hope, and Uranium City. Participants discussed successful and unsuccessful remedial techniques, possible sources of radon, and methods of measuring radon and radon daughters in buildings

  18. Locating and limiting radon in dwellings

    International Nuclear Information System (INIS)

    Hildingson, O.; Gustafsson, J.; Nilsson, I.

    1984-01-01

    More than 3,300 Swedish dwellings have an indoor radon daughter concentration above 400 Bq.m -3 (or 0.108 WL). It is considered to be unsafe to live in any of these dwellings and the radon daughter concentration has to be reduced. Before deciding what measures to take, it is important to determine the radon sources. Possible sources are exhalation from building materials and/or radon transport from the ground into the building through cracks and joints in the slab. Different methods of locating the sources have been developed. To locate cracks and joints in slabs the ventilation rate and the air pressure difference relative to the ground are changed while monitoring radon/radon daughter concentration. The effect of five different measures to reduce the indoor radon daughter concentration have also been evaluated: increased ventilation rate by mechanical ventilation, ventilation of the small spaces between the floor and the slab, sealing the surface of radon exhaling walls, sealing joints and cracks in the slab, and ventilation of the drainage under the slab. (author)

  19. Legal issues in radon affairs

    International Nuclear Information System (INIS)

    Massuelle, M.H.

    1999-01-01

    In France, it was only recently that cases related to high radon concentrations in dwellings received substantial publicity. This irruption of radon as a public health issue came with the general progress of scientific knowledge and the availability of a research capacity in France able to develop expertise. We are interested here in the legal implications of issues that arise from the lag between the activity of experts and the regulatory activity in the domain of radon. We use the term expertise very broadly, to cover the practical application of research findings, the relation of the researchers with the community, and finally the acts by which experts provide their knowledge to the community. We first examine the course by which science developed the radon issue and the way they organized to move from research to expertise; here we try to characterize the various needs for radon expertise. We then discuss the legal difficulties associated with radon expertise

  20. Legal issues in radon affairs

    Energy Technology Data Exchange (ETDEWEB)

    Massuelle, M.H. [Inst. de Protection et de Surete Nucleaire, Fontenay aux Roses (France)

    1999-12-01

    In France, it was only recently that cases related to high radon concentrations in dwellings received substantial publicity. This irruption of radon as a public health issue came with the general progress of scientific knowledge and the availability of a research capacity in France able to develop expertise. We are interested here in the legal implications of issues that arise from the lag between the activity of expertsand the regulatory activity in the domain of radon. We use the term expertise very broadly, to cover the practical application of research findings, the relation of the researchers with the community, and finally the acts by which experts provide their knowledge to the community. We first examine the course by which science developed the radon issue and the way they organized to move from research to expertise; here we try to characterize the various needs for radon expertise. We then discuss the legal difficulties associated with radon expertise.