WorldWideScience

Sample records for epa home heat

  1. EPA ENERGY STAR: Tackling Growth in Home Electronics and Small Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Marla Christine; Brown, Richard; Homan, Gregory

    2008-11-17

    Over a decade ago, the electricity consumption associated with home electronics and other small appliances emerged onto the global energy policy landscape as one of the fastest growing residential end uses with the opportunity to deliver significant energy savings. As our knowledge of this end use matures, it is essential to step back and evaluate the degree to which energy efficiency programs have successfully realized energy savings and where savings opportunities have been missed.For the past fifteen years, we have quantified energy, utility bill, and carbon savings for US EPA?s ENERGY STAR voluntary product labeling program. In this paper, we present a unique look into the US residential program savings claimed to date for EPA?s ENERGY STAR office equipment, consumer electronics, and other small household appliances as well as EPA?s projected program savings over the next five years. We present a top-level discussion identifying program areas where EPA?s ENERGY STAR efforts have succeeded and program areas where ENERGY STAR efforts did not successfully address underlying market factors, technology issues and/or consumer behavior. We end by presenting the magnitude of ?overlooked? savings.

  2. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2012-01-01

    It saddens us deeply to learn of the passing away of Jean-Paul Diss who died suddenly on 7 June 2012 at his home.  A tribute can be read on the GAC-EPA site. * * * * * Information: http://gac-epa.org/ e-mail: gac-epa@gac-epa.org

  3. 76 FR 9780 - Notification of Deletion of System of Records; EPA Parking Control Office File (EPA-10) and EPA...

    Science.gov (United States)

    2011-02-22

    ... System of Records; EPA Parking Control Office File (EPA-10) and EPA Transit and Guaranteed Ride Home... Environmental Protection Agency (EPA) is deleting the systems of records for EPA Parking Control Office File... through the EPA Internet under the ``Federal Register'' listings at http://www.epa.gov/fedrgstr/ . Dated...

  4. Probabilistic assessment of the potential indoor air impacts of vent-free gas heating appliances in energy-efficient homes in the United States.

    Science.gov (United States)

    Whitmyre, Gary K; Pandian, Muhilan D

    2018-06-01

    Use of vent-free gas heating appliances for supplemental heating in U.S. homes is increasing. However, there is currently a lack of information on the potential impact of these appliances on indoor air quality for homes constructed according to energy-efficient and green building standards. A probabilistic analysis was conducted to estimate the impact of vent-free gas heating appliances on indoor air concentrations of carbon monoxide (CO), nitrogen dioxide (NO 2 ), carbon dioxide (CO 2 ), water vapor, and oxygen in "tight" energy-efficient homes in the United States. A total of 20,000 simulations were conducted for each Department of Energy (DOE) heating region to capture a wide range of home sizes, appliance features, and conditions, by varying a number of parameters, e.g., room volume, house volume, outdoor humidity, air exchange rates, appliance input rates (Btu/hr), and house heat loss factors. Predicted airborne levels of CO were below the U.S. Environmental Protection Agency (EPA) standard of 9 ppm for all modeled cases. The airborne concentrations of NO 2 were below the U.S. Consumer Product Safety Commission (CPSC) guideline of 0.3 ppm and the Health Canada benchmark of 0.25 ppm in all cases and were below the World Health Organization (WHO) standard of 0.11 ppm in 99-100% of all cases. Predicted levels of CO 2 were below the Health Canada standard of 3500 ppm for all simulated cases. Oxygen levels in the room of vent-free heating appliance use were not significantly reduced. The great majority of cases in all DOE regions were associated with relative humidity (RH) levels from all indoor water vapor sources that were less than the EPA-recommended 70% RH maximum to avoid active mold and mildew growth. The conclusion of this investigation is that when installed in accordance with the manufacturer's instructions, vent-free gas heating appliances maintain acceptable indoor air quality in tight energy-efficient homes, as defined by the standards referenced in

  5. Heat penetration and thermocouple location in home canning.

    Science.gov (United States)

    Etzel, Mark R; Willmore, Paola; Ingham, Barbara H

    2015-01-01

    We processed applesauce, tomato juice, and cranberries in pint jars in a boiling water canner to test thermal processing theories against home canning of high-acid foods. For each product, thermocouples were placed at various heights in the jar. Values for f h (heating), f cl (cooling), and F 82.2°C (lethality) were determined for each thermocouple location, and did not depend substantially on thermocouple location in accordance with heat transfer theory. There was a cold spot in the jar, but the cold spot during heating became the hot spot during cooling. During heating, the geometric center was the last to heat, and remained coldest the longest, but during coooling, it was also the last to cool, and remained hottest the longest. The net effect was that calculated lethality in home canning was not affected by thermocouple location. Most of the lethality during home canning occurred during air cooling, making cooling of home canned foods of great importance. Calculated lethality was far greater than the required 5-log reduction of spores in tomato juice and vegetative cells in cranberries, suggesting a wide margin of safety for approved home-canning processes for high-acid foods.

  6. Soybean-derived biofuels and home heating fuels.

    Science.gov (United States)

    Mushrush, George W; Wynne, James H; Willauer, Heather D; Lloyd, Christopher L

    2006-01-01

    It is environmentally enticing to consider replacing or blending petroleum derived heating fuels with biofuels for many reasons. Major considerations include the soaring worldwide price of petroleum products, especially home heating oil, the toxicity of the petroleum-derived fuels and the environmental damage that leaking petroleum tanks afford. For these reasons, it has been suggested that domestic renewable energy sources be considered as replacements, or at the least, as blending stocks for home heating fuels. If recycled soy restaurant cooking oils could be employed for this purpose, this would represent an environmental advantage. Renewable plant sources of energy tend to be less toxic than their petroleum counterparts. This is an important consideration when tank leakage occurs. Home fuel oil storage tanks practically always contain some bottom water. This water environment has a pH value that factors into heating fuel stability. Therefore, the question is: would the biofuel help or exacerbate fuel stability and furnace maintenance issues?

  7. Field Measurements of Heating Efficiency of Electric Forced-Air Furnaces in Six Manufactured Homes.

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Bob; Palmiter, Larry S.; Siegel, Jeff

    1994-07-26

    This report presents the results of field measurements of heating efficiency for six manufactured homes in the Pacific Northwest heated with electric forced-air systems. This is the first in a series of regional and national efforts to measure in detail the heating efficiency of manufactured homes. Only six homes were included in this study because of budgetary constraints; therefore this is not a representative sample. These investigations do provide some useful information on the heating efficiency of these homes. Useful comparisons can be drawn between these study homes and site-built heating efficiencies measured with a similar protocol. The protocol used to test these homes is very similar to another Ecotope protocol used in the study conducted in 1992 and 1993 for the Bonneville Power Administration to test the heating efficiency of 24 homes. This protocol combined real-time power measurements of furnace energy usage with energy usage during co-heat periods. Accessory data such as house and duct tightness measurements and tracer gas measurements were used to describe these homes and their heating system efficiency. Ensuring that manufactured housing is constructed in an energy and resource efficient manner is of increasing concern to manufactured home builders and consumers. No comparable work has been done to measure the heating system efficiency of MCS manufactured homes, although some co-heat tests have been performed on manufactured homes heated with natural gas to validate HUD thermal standards. It is expected that later in 1994 more research of this kind will be conducted, and perhaps a less costly and less time-consuming method for testing efficiencies will be develops.

  8. Low-cost measurement techniques to characterize the influence of home heating fuel on carbon monoxide in Navajo homes.

    Science.gov (United States)

    Casey, Joanna Gordon; Ortega, John; Coffey, Evan; Hannigan, Michael

    2018-06-01

    A large fraction of the global population relies on the inefficient combustion of solid fuels for cooking and home heating, resulting in household exposure to combustion byproducts. In the southwestern United States, unhealthy air quality has been observed in some homes that use solid fuels as a primary source of heat on the Navajo Nation. In order to better understand how home heating fuel choice can influence indoor air quality in this region, we used recently developed low-cost electrochemical sensors to measure carbon monoxide (CO) air mole fractions continuously inside and outside 41 homes in two communities on the Navajo Nation. Using low-cost sensors in this study, which don't require extensive training to operate, enabled collaboration with local Diné College students and faculty in the planning and implementation of home deployments. Households used natural gas, propane, pellets, wood, and/or coal for heating. We developed quantification methods that included uncertainty estimation for Alphasense CO-B4 sensors, for measurements both inside and outside homes. CO concentrations elevated above background were observed in homes in each heating fuel group, but the highest hourly concentrations were observed in wood and coal burning homes, some of which exceeded World Health Organization Guidelines on both an hourly and eight-hourly basis. In order to probe the many factors that can influence indoor pollutant concentrations, we developed and implemented methods that employ CO emission and decay time periods observed in homes during everyday activities to estimate air exchange rates as well as CO emission rates on the basis of a given well-mixed volume of air. The air quality measurement tools and methods demonstrated in this study can be readily extended to indoor air quality studies in other communities around the world to inform how home heating and cooking practices are influencing indoor air quality during normal daily activities. Copyright © 2018 Elsevier

  9. Living in cold homes after heating improvements: Evidence from Warm-Front, England's Home Energy Efficiency Scheme

    International Nuclear Information System (INIS)

    Critchley, Roger; Gilbertson, Jan; Grimsley, Michael; Green, Geoff

    2007-01-01

    Objective: To investigate explanatory factors for persistent cold temperatures in homes which have received heating improvements. Design: Analysis of data from a national survey of dwellings and households (in England occupied by low-income residents) that had received heating improvements or repairs under the Warm Front Scheme. Methods: Over the winters of 2001-02 and 2002-03, householders recorded living room and main bedroom temperatures in a diary. Entries were examined for 888 households, which had received high level heating interventions. Two hundred and twenty-two households were identified as occupying cold homes, with mean bedroom temperature below 16 deg. C or mean living room temperatures below 18 deg. C. Binary logistic regression was used to model dwelling and household features and then occupants' behaviour and attitudes in the 'cold homes' sub-set compared with the remainder of the high intervention group. Seventy-nine supplementary, structured telephone interviews explored reasons given for lower temperatures. Using graphical and tabular methods, householders preferring cooler homes were distinguished from those who felt constrained in some way. Results: Cold homes predominate in pre-1930 properties where the householder remains dissatisfied with the heating system despite major improvements funded by Warm Front. Residents of cold homes are less likely to have long-standing illness or disability, but more likely to experience anxiety or depression. A small sample of telephone interviews reveals those preferring lower temperatures for health or other reasons, report less anxiety and depression than those with limited control over their home environment. Their 'thermal resistance' to higher temperatures challenges orthodox definitions of comfort and fuel poverty

  10. Heating homes and water with the sun. Solar thermal solutions adapted to individual homes

    International Nuclear Information System (INIS)

    Bareau, Helene; Juniere, Olivier; Leplay, Camille

    2016-09-01

    This brochure, edited by ADEME, the French office for energy management and sustainable development, gives a basic outlook of the way to complete the installation of a solar space and hot water heating system in an individual home. After some recall of the key points to be considered before taking the decision to invest in a solar heating system (minimum surface, orientation, etc.) and the main administrative procedures to be respected (in France), this document presents the common individual solar water heating system (which is now reliable and robust), its various equipment and operating principles, the dimensioning of the system, gives recommendations on points such as the panel position and orientation, the risk of overheating and the way to avoid it, etc. It also presents combined solar heating solutions that simultaneously heat water and space, their operating principles and the way to complete their installation for a home. Informations on financing, selection of the equipment and the installer, and installation maintenance are also proposed

  11. Our winters of discontent : addressing the problem of rising home heating costs

    International Nuclear Information System (INIS)

    Hughes, L.; Wysocki, A.

    2006-03-01

    The cost of space heating may soon increase due to rising fuel prices in international energy markets and the absence of federal and provincial energy security policies. This report examined the benefits and disadvantages of 2 approaches to assist those with limited incomes to meet heating requirements: (1) offering Low Income Fuel Assistance (LIFA) as a one-time payment during the heating season; and (2) the elimination of taxes for home heating fuels. The cost of home heating fuels and their impacts on consumers and governments were considered. A review of the Nova Scotia government's Keep the Heat program noted that the program was not responsive to increases in the price of home heating fuel, particularly if increases in a year exceeded the level of assistance. It was suggested that the removal of heating sales taxes could provide unnecessary windfalls to households with large homes, as well as windfall profits for landlords if savings were not passed on to tenants. Using Nova Scotia as a case study, an alternative support system was considered that guaranteed a set price for heating fuel for those in need. It was suggested that this approach could cost less than a lump-sum payment or the elimination of taxes on home-heating fuel. In addition, the approach would provide low-income consumers with predictable and affordable prices. It was concluded that as space heating energy costs continue to rise, all government fuel assistance programs run the risk of becoming larger and more costly. Other solutions included reducing Canada's dependence on fossil fuels through the use of solar energy; the reduction of residential energy demand; and the promotion of district heating. 26 refs., 9 tabs., 3 figs

  12. Electric heating provides a high level of home comfort - economically

    Energy Technology Data Exchange (ETDEWEB)

    Haapakoski, M.

    1997-11-01

    Research and development at IVO in the area of electric heating boasts a tradition going back almost thirty years. Research aimed at further progress is continuing. IVO and power companies launched the `Electrically heated houses of the century` project four years ago. The first results show that electric heating continues to be very competitive with other heating systems. It is an economical way of heating the home and it also increases the comfort of those living there

  13. Heat Islands

    Science.gov (United States)

    EPA's Heat Island Effect Site provides information on heat islands, their impacts, mitigation strategies, related research, a directory of heat island reduction initiatives in U.S. communities, and EPA's Heat Island Reduction Program.

  14. Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

    Energy Technology Data Exchange (ETDEWEB)

    Backman, C. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); German, A. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Dakin, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Springer, D. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2013-12-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  15. Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

    Energy Technology Data Exchange (ETDEWEB)

    Backman, C. [Alliance for Residential Building Innovation, Davis, CA (United States). Davis Energy Group; German, A. [Alliance for Residential Building Innovation, Davis, CA (United States). Davis Energy Group; Dakin, B. [Alliance for Residential Building Innovation, Davis, CA (United States). Davis Energy Group; Springer, D. [Alliance for Residential Building Innovation, Davis, CA (United States). Davis Energy Group

    2013-12-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  16. Solar heating and cooling of mobile homes, Phase II. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, A.A.

    1976-12-01

    The specific objectives of the Phase II program were: (1) through system testing, confirm the feasibility of a solar heated and cooled mobile home; (2) update system performance analysis and provide solar heating and cooling computer model verification; (3) evaluate the performance of both an absorption and a Rankine air conditioning system; (4) perform a consumer demand analysis through field survey to ascertain the acceptance of solar energy into the mobile home market; and (5) while at field locations to conduct the consumer demand analysis, gather test data from various U.S. climatic zones. Results are presented and discussed. (WHK)

  17. Electric radiant heating: A hot item in home comfort

    Energy Technology Data Exchange (ETDEWEB)

    Lemieux, G. [Britech Corp., Toronto, ON (Canada)

    2003-12-01

    Electric radiant heating as a floor warming system and its growing popularity in home comfort are discussed. Price can be as low as $2.00 per square foot; cost of operation may be as little as 30 cents per square foot per year, depending on time of use and local hydro rates. The use of radiant cable heating is said to have surged in popularity; it provides the same warmth and comfort as more expensive hydronic systems. Radiant cable is simple and inexpensive to install since unlike hydronic systems, it requires no complicated mechanical system with boiler, heat exchanger, valves, pumps and extensive controls. Nevertheless, prospective end users are warned to make sure that the cable is sturdy, tough, has multiple layers of protection with a thick grounding system and conductor core. In addition to heating floors, electric heating cables can also be used for snow and ice control and for melting in driveways and gutters. In these type of installations heavy duty cables are used which are installed under asphalt, concrete or interlocking stones. Thirty watts per square foot per hour is the typical requirement for melting snow and ice. Based on average electricity prices in Ontario, melting snow on an 800 square foot driveway would cost about $2.20 per hour. Assuming five hours for the system to clear the driveway, installing a heating system under the driveway could be an economically viable solution for the home owner, providing freedom from ice, the inconvenience of shovelling snow, and saving time and money.

  18. Indirect Solar Water Heating in Single-Family, Zero Energy Ready Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, Robb [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2016-02-17

    Solar water heating systems are not new, but they have not become prevalent in most of the U.S. Most of the country is cold enough that indirect solar thermal systems are required for freeze protection, and average installed cost of these systems is $9,000 to $10,000 for typical systems on single-family homes. These costs can vary significantly in different markets and with different contractors, and federal and regional incentives can reduce these up-front costs by 50% or more. In western Massachusetts, an affordable housing developer built a community of 20 homes with a goal of approaching zero net energy consumption. In addition to excellent thermal envelopes and PV systems, the developer installed a solar domestic water heating system (SDHW) on each home. The Consortium for Advanced Residential Buildings (CARB), a research consortium funded by the U.S. Department of Energy Building America program, commissioned some of the systems, and CARB was able to monitor detailed performance of one system for 28 months.

  19. A pilot effectiveness study of the Enhancing Parenting Skills (EPaS) 2014 programme for parents of children with behaviour problems: study protocol for a randomised controlled trial

    OpenAIRE

    Williams, Margiad Elen; Hutchings, Judy

    2015-01-01

    Background The Enhancing Parenting Skills (EPaS) 2014 programme is a home-based, health visitor-delivered parenting support programme for parents of children with identified behaviour problems. This trial aims to evaluate the effectiveness of the EPaS 2014 programme compared to a waiting-list treatment as usual control group. Methods/Design This is a pragmatic, multicentre randomised controlled trial. Sixty health visitors will each be asked to identify two families that have a child scoring ...

  20. Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes -- Habitat for Humanity The Woods

    Energy Technology Data Exchange (ETDEWEB)

    Lubliner, Michael [Building America Partnership for Improved Residential Construction, Olympia, WA (United States). Washington States Univ. Energy Program; Howard, Luke [Building America Partnership for Improved Residential Construction, Olympia, WA (United States). Washington States Univ. Energy Program; Hales, David [Building America Partnership for Improved Residential Construction, Olympia, WA (United States). Washington States Univ. Energy Program; Kunkle, Rick [Building America Partnership for Improved Residential Construction, Olympia, WA (United States). Washington States Univ. Energy Program; Gordon, Andy [Building America Partnership for Improved Residential Construction, Olympia, WA (United States). Washington States Univ. Energy Program; Spencer, Melinda [Building America Partnership for Improved Residential Construction, Olympia, WA (United States). Washington States Univ. Energy Program

    2016-02-18

    The Woods is a Habitat for Humanity (HFH) community of ENERGY STAR Homes Northwest (ESHNW)-certified homes located in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report, and includes significant billing analysis and cost effectiveness research from a collaborative, ongoing Ductless Heat Pump (DHP)research effort for Tacoma Public Utilities (TPU) and Bonneville Power Administration (BPA). This report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing such as HFH. Tacoma Public Utilities (TPU) and Bonneville Power Administration (BPA). This report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing such as HFH.

  1. A Modified EPA Method 1623 that Uses Tangential Flow Hollow-Fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidum and Giardia spp.

    Science.gov (United States)

    This protocol describes the use of a tangential flow hollow-fiber ultrafiltration sample concentration system and a heat dissociation as alternative steps for the detection of waterborne Cryptosporidium and Giardia species using EPA Method 1623.

  2. Keeping warm? Self-reported housing and home energy efficiency factors impacting on older people heating homes in North Wales

    International Nuclear Information System (INIS)

    Burholt, Vanessa; Windle, Gill

    2006-01-01

    This paper examines a representative sample (N=421) of older people (aged 70+) living in rural North Wales with regard to relationships between fuel poverty, feeling cold in one's home and a range of self-reported housing and home energy efficiency items. In the Welsh context, the combination of poor housing stock and low-level income is likely to increase the chance of older people experiencing fuel poverty, therefore the analyses are relevant to both energy and social policy. The paper hypothesises that: (i) People in 'fuel poor' homes are: low-income households; living in older houses; lacking home energy efficiency measures; (ii) not all people facing difficulties heating their home (i.e. wearing extra clothing to keep warm during cold spells) are identified as 'fuel poor', but there will be an association between taking extra measures to keep warm and low income; older houses and lacking home energy efficiency factors. The results partially support the hypotheses. An estimation is made of the expenditure required to counter the factors associated with fuel poverty and cold homes in the region. The paper concludes with implications for the UK Fuel Poverty Strategy

  3. Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes -- Habitat for Humanity The Woods

    Energy Technology Data Exchange (ETDEWEB)

    Lubliner, Michael [Washington State Univ., Pullman, WA (United States); Howard, Luke [Washington State Univ., Pullman, WA (United States); Hales, David [Washington State Univ., Pullman, WA (United States); Kunkle, Rick [Washington State Univ., Pullman, WA (United States); Gordon, Andy [Washington State Univ., Pullman, WA (United States); Spencer, Melinda [Washington State Univ., Pullman, WA (United States)

    2016-02-23

    This final Building America Partnership report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing.

  4. A pilot effectiveness study of the Enhancing Parenting Skills (EPaS) 2014 programme for parents of children with behaviour problems: study protocol for a randomised controlled trial.

    Science.gov (United States)

    Williams, Margiad Elen; Hutchings, Judy

    2015-05-20

    The Enhancing Parenting Skills (EPaS) 2014 programme is a home-based, health visitor-delivered parenting support programme for parents of children with identified behaviour problems. This trial aims to evaluate the effectiveness of the EPaS 2014 programme compared to a waiting-list treatment as usual control group. This is a pragmatic, multicentre randomised controlled trial. Sixty health visitors will each be asked to identify two families that have a child scoring above the clinical cut-off for behaviour problems using the Eyberg Child Behaviour Inventory (ECBI). Families recruited to the trial will be randomised in a 1:1 ratio into an intervention or waiting-list control group. Randomisation will occur within health visitor to ensure that each health visitor has one intervention family and one control family. The primary outcome is change in child behaviour problems as measured by the parent-reported ECBI. Secondary outcomes include other measures of child behaviour, parent behaviour, and parental depression as measured by parent-reports and an independent observation of parent and child behaviour. Follow-up measures will be collected 6-months after the collection of baseline measures. This is the first rigorous evaluation of the EPaS 2014 programme. The trial will provide important information on the effectiveness of a one-to-one home-based intervention, delivered by health visitors, for pre-school children with behaviour problems. It will also examine potential mediating (improved parent behaviour and/or improved parental depression) and moderating (single parent, teenage parent, poverty, low education level) factors. Current Controlled Trials ISRCTN06867279 (18 June 2014).

  5. STUDY ON THE THERMAL STABILITY OF EPA AND DHA IN MUJAHIR (Oreochromis mossambicus FISH OIL

    Directory of Open Access Journals (Sweden)

    Ngatidjo Hadipranoto

    2010-06-01

    Full Text Available EPA (Eicosapentaenoic acid and DHA (Docosahexaenoic acid content in common fresh water fish : mujahir (Oreochromis mossambicus after indirect heating were analysed. The aims of this study were to determine the effect of indirect heating process and α-tocopherol additions on both fatty acid stability.Lipids content in the mujahir fillets were extracted by Folch method using chloroform-metanol (2:1 mixture. Fatty acids in fish oil were converted to fatty acid methyl esters and then injected into gas chromatography to determine the EPA and DHA concentration. Operating condition of gas chromatography were programmed as follows: injection port temperature at 270 oC, detector at 280 oC, initial column temperature at 200 oC, and the final at 280 oC, the carrier gas was helium with flow rate of 10 ml per minute and temperature of column was increased gradually at 10 oC per minute. The effect of α-tocopherol addition on the stability of EPA and DHA was studied by adding α-tocopherol at 50 to 200 mg per kilogram sample before indirect heating process was carried out.The analysis of mujahir fish oil showed that the content of EPA and DHA in 100 grams fresh sample was 105 and 406,5 mg respectivelly. Indirect heating caused the EPA and DHA content decreased significantly. The addition of α-tocopherol results in a positive corelation between α-tocopherol concentration added and the decrease of EPA and DHA content during the heating process.   Keywords: fatty acid, eicosapentaenoic acid, docosahexaenoic acid

  6. Ultra Low Sulfur Home Heating Oil Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Batey, John E. [Energy Research Center, Inc., Easton, CT (United States); McDonald, Roger [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-09-30

    This Ultra Low Sulfur (ULS) Home Heating Oil Demonstration Project was funded by the New York State Energy Research and Development Authority (NYSERDA) and has successfully quantified the environmental and economic benefits of switching to ULS (15 PPM sulfur) heating oil. It advances a prior field study of Low Sulfur (500 ppm sulfur) heating oil funded by NYSERDA and laboratory research conducted by Brookhaven National Laboratory (BNL) and Canadian researchers. The sulfur oxide and particulate matter (PM) emissions are greatly reduced as are boiler cleaning costs through extending cleaning intervals. Both the sulfur oxide and PM emission rates are directly related to the fuel oil sulfur content. The sulfur oxide and PM emission rates approach near-zero levels by switching heating equipment to ULS fuel oil, and these emissions become comparable to heating equipment fired by natural gas. This demonstration project included an in-depth review and analysis of service records for both the ULS and control groups to determine any difference in the service needs for the two groups. The detailed service records for both groups were collected and analyzed and the results were entered into two spreadsheets that enabled a quantitative side-by-side comparison of equipment service for the entire duration of the ULS test project. The service frequency for the ULS and control group were very similar and did indicate increased service frequency for the ULS group. In fact, the service frequency with the ULS group was slightly less (7.5 percent) than the control group. The only exception was that three burner fuel pump required replacement for the ULS group and none were required for the control group.

  7. Air-To-Water Heat Pumps with Radiant Delivery in Low Load Homes: Tucson, Arizona and Chico, California (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2013-11-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  8. Residential home heating: The potential for air source heat pump technologies as an alternative to solid and liquid fuels

    International Nuclear Information System (INIS)

    Kelly, J. Andrew; Fu, Miao; Clinch, J. Peter

    2016-01-01

    International commitments on greenhouse gases, renewables and air quality warrant consideration of alternative residential heating technologies. The residential sector in Ireland accounts for approximately 25% of primary energy demand with roughly half of primary home heating fuelled by oil and 11% by solid fuels. Displacing oil and solid fuel usage with air source heat pump (ASHP) technology could offer household cost savings, reductions in emissions, and reduced health impacts. An economic analysis estimates that 60% of homes using oil, have the potential to deliver savings in the region of €600 per annum when considering both running and annualised capital costs. Scenario analysis estimates that a grant of €2400 could increase the potential market uptake of oil users by up to 17% points, whilst a higher oil price, similar to 2013, could further increase uptake from heating oil users by 24% points. Under a combined oil-price and grant scenario, CO_2 emissions reduce by over 4 million tonnes per annum and residential PM_2_._5 and NO_X emissions from oil and peat reduce close to zero. Corresponding health and environmental benefits are estimated in the region of €100m per annum. Sensitivity analyses are presented assessing the impact of alternate discount rates and technology performance. This research confirms the potential for ASHP technology and identifies and informs policy design considerations with regard to oil price trends, access to capital, targeting of grants, and addressing transactions costs. - Highlights: • Air Source Heat Pumps can offer substantial savings over oil fired central heating. • Significant residential air and climate emission reductions are possible. • Associated health and environmental benefits are estimated up to €100m per annum. • Results can inform policy interventions in the residential market to support change.

  9. 24 CFR 3280.506 - Heat loss/heat gain.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Heat loss/heat gain. 3280.506... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.506 Heat loss/heat gain. The manufactured home heat loss/heat gain shall be determined by methods outlined in...

  10. Household preferences of hybrid home heating systems – A choice experiment application

    International Nuclear Information System (INIS)

    Ruokamo, Enni

    2016-01-01

    The residential heating sector presents considerable energy savings potential, as numerous heating solutions for reducing electricity consumption and utilizing renewable energy sources are available in the market. The aim of this paper is to examine determinants of household heating system choices and to use this information for policy planning purposes. This paper investigates residential homeowner attitudes regarding innovative hybrid home heating systems (HHHS) with choice experiment. Heating system scenarios are designed to represent the most relevant primary and supplementary heating alternatives currently available in Finland. The choice sets include six main heating alternatives (district heat, solid wood, wood pellet, electric storage heating, ground heat pump and exhaust air heat pump) that are described by five attributes (supplementary heating systems, investment costs, operating costs, comfort of use and environmental friendliness). The results imply that HHHSs generally appear to be accepted among households; however, several factors affect perceptions of these technologies. The results reveal differing household attitudes toward the main heating alternatives and show that such views are affected by socio-demographic characteristics (age, living environment, education, etc.). The results suggest that households view supplementary heating systems (especially solar-based) favorably. The other attributes studied also play a significant role in decision making. - Highlights: •Study of hybrid heating where supplementary and main heating systems are combined. •Choice experiment is applied to study the determinants of hybrid heating adoption. •Hybrid heating appears to be generally accepted among households. •Households exhibit differing attitudes toward hybrid heating. •Policy makers should not underestimate the potential of hybrid heating.

  11. Recommended Ventilation Strategies for Energy-Efficient Production Homes

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, J.; Brown, R.; Koomey, J.; Warner, J.; Greenberg, S.

    1998-12-01

    This report evaluates residential ventilation systems for the U.S. Environmental Protection Agency's (EPA's) ENERGY STAR{reg_sign} Homes program and recommends mechanical ventilation strategies for new, low-infiltration, energy-efficient, single-family, ENERGY STAR production (site-built tract) homes in four climates: cold, mixed (cold and hot), hot humid, and hot arid. Our group in the Energy Analysis Department at Lawrence Berkeley National Lab compared residential ventilation strategies in four climates according to three criteria: total annualized costs (the sum of annualized capital cost and annual operating cost), predominant indoor pressure induced by the ventilation system, and distribution of ventilation air within the home. The mechanical ventilation systems modeled deliver 0.35 air changes per hour continuously, regardless of actual infiltration or occupant window-opening behavior. Based on the assumptions and analysis described in this report, we recommend independently ducted multi-port supply ventilation in all climates except cold because this strategy provides the safety and health benefits of positive indoor pressure as well as the ability to dehumidify and filter ventilation air. In cold climates, we recommend that multi-port supply ventilation be balanced by a single-port exhaust ventilation fan, and that builders offer balanced heat-recovery ventilation to buyers as an optional upgrade. For builders who continue to install forced-air integrated supply ventilation, we recommend ensuring ducts are airtight or in conditioned space, installing a control that automatically operates the forced-air fan 15-20 minutes during each hour that the fan does not operate for heating or cooling, and offering ICM forced-air fans to home buyers as an upgrade.

  12. DOE Zero Energy Ready Home Case Study, Weiss Building & Development, LLC., System Home, River Forest, Illinois

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2013-09-01

    The Passive House Challenge Home located in River Forest, Illinois, is a 5-bedroom, 4.5-bath, 3,600 ft2 two-story home (plus basement) that costs about $237 less per month to operate than a similar sized home built to the 2009 IECC. For a home with no solar photovoltaic panels installed, it scored an amazingly low 27 on the Home Energy Rating System (HERS) score.An ENERGY STAR-rated dishwasher, clothes washer, and refrigerator; an induction cooktop, condensing clothes dryer, and LED lighting are among the energy-saving devices inside the home. All plumbing fixtures comply with EPA WaterSense criteria. The home was awarded a 2013 Housing Innovation Award in the "systems builder" category.

  13. Home automation becomes home entertainment. Emotion replaces function; Hausautomation sucht Naehe zum Home-Entertainment. Emotion verdraengt Funktion

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, W.

    2006-09-15

    Home automation commonly applies to control of lighting, shading, heating, safety etc., i.e. a purely functional concept. Recently, many systems have come to integrate home entertainment as well: Bang and Olufsen and Revox meets heating, light, and ventilation. (orig.)

  14. Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support

    Energy Technology Data Exchange (ETDEWEB)

    Herk, Anastasia [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-01-01

    IBACOS worked with builder Imagine Homes to evaluate the performance of an occupied new construction test house following construction of the house in the hot, humid climate of San Antonio, Texas. The project measures the effectiveness of a space conditioning strategy using a multihead mini-split heat pump (MSHP) system in a reduced-load home to achieve acceptable comfort levels (temperature and humidity) and energy performance. IBACOS collected long-term data and analyzed the energy consumption and comfort conditions of the occupied house after one year of operation. Although measured results indicate that the test system provides comfort both inside and outside the ASHRAE Standard 55-2010 range, the occupants of the house claimed both adequate comfort and appreciation of the ease of use and flexibility of the installed MSHP system. IBACOS also assisted the builder to evaluate design and specification changes necessary to comply with Zero Energy Ready Home, but the builder chose to not move forward with it because of concerns about the 'solar ready' requirements of the program.

  15. Heat Pump Water Heaters and American Homes: A Good Fit?

    Energy Technology Data Exchange (ETDEWEB)

    Franco, Victor; Lekov, Alex; Meyers, Steve; Letschert, Virginie

    2010-05-14

    Heat pump water heaters (HPWHs) are over twice as energy-efficient as conventional electric resistance water heaters, with the potential to save substantial amounts of electricity. Drawing on analysis conducted for the U.S. Department of Energy's recently-concluded rulemaking on amended standards for water heaters, this paper evaluates key issues that will determine how well, and to what extent, this technology will fit in American homes. The key issues include: 1) equipment cost of HPWHs; 2) cooling of the indoor environment by HPWHs; 3) size and air flow requirements of HPWHs; 4) performance of HPWH under different climate conditions and varying hot water use patterns; and 5) operating cost savings under different electricity prices and hot water use. The paper presents the results of a life-cycle cost analysis of the adoption of HPWHs in a representative sample of American homes, as well as national impact analysis for different market share scenarios. Assuming equipment costs that would result from high production volume, the results show that HPWHs can be cost effective in all regions for most single family homes, especially when the water heater is not installed in a conditioned space. HPWHs are not cost effective for most manufactured home and multi-family installations, due to lower average hot water use and the water heater in the majority of cases being installed in conditioned space, where cooling of the indoor environment and size and air flow requirements of HPWHs increase installation costs.

  16. Risk Assessment of Heating, Ventilating, and Air-Conditioning Strategies in Low-Load Homes

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2016-02-17

    "Modern, energy efficient homes conforming to the Zero Energy Ready Home standard face the challenge of meeting high customer expectations for comfort. Traditional heating, ventilation, and air conditioning (HVAC) sizing and control strategies may be insufficient to adequately condition each zone due to unique load patterns in each room caused by a number of factors. These factors include solar heat gains, occupant-related gains, and gains associated with appliances and electronics. Because of shrinking shell loads, these intermittent factors are having an increasingly significant impact on the thermal load in each zone. Consequently, occupant comfort can be compromised. To evaluate the impact of climate and house geometry, as well as HVAC system and control strategies on comfort conditions, IBACOS analyzed the results of 99 TRNSYS multiple-zone simulations. The results of this analysis indicate that for simple-geometry and single-story plans, a single zone and thermostat can adequately condition the entire house. Demanding house geometry and houses with multiple stories require the consideration of multiple thermostats and multiple zones.

  17. Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support

    Energy Technology Data Exchange (ETDEWEB)

    Herk, Anastasia [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-01-01

    This project was created from a partnership between the U.S. Department of Energy’s (DOE’s) Building America research team IBACOS, Inc. and Imagine Homes, a production homebuilder of high-performance homes in San Antonio, Texas—a hot-humid climate. The primary purpose was to evaluate the performance of a multihead mini-split heat pump (MSHP) space-conditioning system, which consists of ducted and ductless indoor units, in maintaining uniform comfort in an occupied test house. The research team evaluated the MSHP space-conditioning strategy for its effectiveness in achieving uniform temperature and relative humidity (RH) levels throughout the test house and for overall constructability and cost. This evaluation was based on data that were collected from short-term tests and monitoring during 1 year of occupancy, as well as from builder and occupant feedback. Design considerations for integrating an MSHP system into the builder’s full range of production home designs were also explored, with a focus on minimizing the cost and complexity of the system design while meeting the thermal loads of the house and providing occupant comfort according to ANSI/ASHRAE Standard 55-2010 (ASHRAE 2010a).

  18. Role of Solar Water Heating in Multifamily Zero Energy Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, Robb [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Williamson, James [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2016-04-08

    Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: 1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads; 2) Because of better scale, SDHW systems in multifamily buildings cost significantly less per dwelling than in single-family homes; 3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating; and 4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support from the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.

  19. A run-around heat exchanger system to improve the energy efficiency of a home appliance using hot water

    International Nuclear Information System (INIS)

    Park, Jae Sung; Jacobi, Anthony M.

    2009-01-01

    A significant portion of the energy consumed by many home appliances using hot water is used to heat cold supply water. Such home appliances generally are supplied water at a temperature lower than the ambient temperature, and the supply water is normally heated to its maximum operating temperature, often using natural gas or an electrical heater. In some cases, it is possible to pre-heat the supply water and save energy that would normally be consumed by the natural gas or electrical heater. In order to save the energy consumed by an appliance using water heater, a run-around heat exchanger system is used to transfer heat from the ambient to the water before an electrical heater is energized. A simple model to predict the performance of this system is developed and validated, and the model is used to explore design and operating issues relevant to the run-around heat exchanger system. Despite the additional power consumption by the fan and pump of the run-around heat exchanger system, the experimental data and analysis show that for some systems the overall energy efficiency of the appliance can be improved, saving about 6% of the energy used by the baseline machine.

  20. Protecting Your Home from Bed Bugs

    Science.gov (United States)

    ... your home: Inspect the luggage rack in your hotel room for bed bugs. Check secondhand furniture, beds, ... with Bed Bug Problems Discover. Accessibility EPA Administrator Budget & Performance Contracting Grants January 19, 2017 Web Snapshot ...

  1. HomePort

    DEFF Research Database (Denmark)

    Madsen, Per Printz

    2009-01-01

    In the last couple of year's computer based home control systems are getting more and more common in modern homes. For instance these systems take care of light control, heat control and security systems.  The latest trend is to use wireless communication like Z-Wave and ZigBee to interconnect...... different components in these systems. One of the characteristics is that each system, like for instance heat and light, has their own specific way of using the communication system.   This paper describes a way to connect different home control systems through an intelligent gateway, called a Home......Port. The HomePort consists of a number of Subsystem communication drivers, a virtual communication layer, an interpreter and a PC- based compiler for a high level control language, called GIL (Gateway intelligence language). The focus in this paper will be on the upper two layers in the Home...

  2. Evaluating Moisture Control of Variable-Capacity Heat Pumps in Mechanically Ventilated, Low-Load Homes in Climate Zone 2A

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Eric [Univ. of Central Florida, Orlando, FL (United States). Florida Solar Energy Center; Withers, Chuck [Univ. of Central Florida, Orlando, FL (United States). Florida Solar Energy Center; McIlvaine, Janet [Univ. of Central Florida, Orlando, FL (United States). Florida Solar Energy Center; Chasar, Dave [Univ. of Central Florida, Orlando, FL (United States). Florida Solar Energy Center; Beal, David [Univ. of Central Florida, Orlando, FL (United States). Florida Solar Energy Center

    2018-02-07

    The well-sealed, highly insulated building enclosures constructed by today's home building industry coupled with efficient lighting and appliances are achieving significantly reduced heating and cooling loads. These low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. Even if fixed-capacity equipment can be properly specified for peak loads, it remains oversized for use during much of the year. During these part-load cooling hours, oversized equipment meets the target dry-bulb temperatures very quickly, often without sufficient opportunity for moisture control. The problem becomes more acute for high-performance houses in humid climates when meeting ASHRAE Standard 62.2 recommendations for wholehouse mechanical ventilation.

  3. New Whole-House Solutions Case Study: Performance and Costs of Ductless Heat Pumps in Marine Climate High-Performance Homes

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-02-24

    The Woods is a sustainable community built by Habitat for Humanity in 2013. This community comprises 30 homes that are high-performance and energy-efficient. With support from Tacoma Public Utilities and the Bonneville Power Administration, the BA-PIRC team is researching the energy performance of these homes and the ductless heat pumps they employ.

  4. Evaluating Moisture Control of Variable-Capacity Heat Pumps in Mechanically Ventilated, Low-Load Homes in Climate Zone 2A

    Energy Technology Data Exchange (ETDEWEB)

    Eric Martin, Chuck Withers, Janet McIlvaine, Dave Chasar, and David Beal

    2018-03-29

    Low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. This report evaluates the performance of variable-capacity comfort systems, with a focus on inverter-driven, variable-capacity systems, as well as proposed system enhancements.

  5. A happy marriage. In his private home, heating systems expert Ulrich Krausscombines photovoltaic power generation and geothermal heat; Eine glueckliche Verbindung. Heizungsfachmann Ulrich Krauss kombiniert in seinem Haus Photovoltaik und Erdwaerme

    Energy Technology Data Exchange (ETDEWEB)

    Simons, Kristina; Krause, Matthias B.

    2010-11-15

    The contribution presents a private home with photovoltaic cells installed on the garage roof and with geothermal heating. In spite of unfavourable boundary conditions, the solar modules produce more electric power than the geothermal heat pump consumes. (orig.)

  6. DOE Zero Energy Ready Home Case Study: TC Legend Homes, Seattle, Washington

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2013-09-01

    This house incorporates slab-on-grade, EPS roof, and radiant heating with an air-to-water heat pump that also preheats domestic hot water. Without counting in the solar panels, the home earns a home energy rating system (HERS) score of 37, with projected utility bills of about $740 a year. With the 6.4-kW photovoltaic power system installed on the roof, the home’s HERS scores drops to -1 and utility bills for the all-electric home drop to zero. This home was awarded a 2013 Housing Innovation Award in the affordable builder category.

  7. Indoor air pollution by different heating systems: coal burning, open fireplace and central heating.

    Science.gov (United States)

    Moriske, H J; Drews, M; Ebert, G; Menk, G; Scheller, C; Schöndube, M; Konieczny, L

    1996-11-01

    Investigations of indoor air pollution by different heating systems in private homes are described. Sixteen homes, 7 with coal burning, 1 with open fireplace (wood burning) and 8 with central heating have been investigated. We measured the concentrations of carbon monoxide, carbon dioxide and sedimented dust in indoor air, of total suspended particulates, heavy metals and of polycyclic aromatic hydrocarbons in indoor and outdoor air. Measurements were taken during winter (heating period) and during summer (non-heating period). Generally, we found higher indoor air pollution in homes with coal burning and open fireplace than in homes with central heating. Especially, the concentrations of carbon monoxide, sedimented dust and of some heavy metals were higher. In one case, we found also high indoor air pollution in a home with central heating. This apartment is on the ground floor of a block of flats, and the central heating system in the basement showed a malfunctioning of the exhaust system.

  8. Living with an autonomous spatiotemporal home heating system: Exploration of the user experiences (UX) through a longitudinal technology intervention-based mixed-methods approach.

    Science.gov (United States)

    Kruusimagi, Martin; Sharples, Sarah; Robinson, Darren

    2017-11-01

    Rising energy demands place pressure on domestic energy consumption, but savings can be delivered through home automation and engaging users with their heating and energy behaviours. The aim of this paper is to explore user experiences (UX) of living with an automated heating system regarding experiences of control, understanding of the system, emerging thermal behaviours, and interactions with the system as this area is not sufficiently researched in the existing homes setting through extended deployment. We present a longitudinal deployment of a quasi-autonomous spatiotemporal home heating system in three homes. Users were provided with a smartphone control application linked to a self-learning heating algorithm. Rich qualitative and quantitative data presented here enabled a holistic exploration of UX. The paper's contribution focuses on highlighting key aspects of UX living with an automated heating systems including (i) adoption of the control interface into the social context, (ii) how users' vigilance in maintaining preferred conditions prevailed as a better indicator of system over-ride than gross deviation from thermal comfort, (iii) limited but motivated proactivity in system-initiated communications as best strategy for soliciting user feedback when inference fails, and (iv) two main motivations for interacting with the interface - managing irregularities when absent from the house and maintaining immediate comfort, latter compromising of a checking behaviour that can transit to a system state alteration behaviour depending on mismatches. We conclude by highlighting the complex socio-technical context in which thermal decisions are made in a situated action manner, and by calling for a more holistic, UX-focused approach in the design of automated home systems involving user experiences. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. DOE Zero Energy Ready Home Case Study: Weiss Building & Development, Downers Grove, Illinois

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2013-09-01

    This single-family home built in a peat bog has underground storage tanks and drainage tanks, blown fiberglass insulation, coated rigid polyisocyanurate, and flashing. The 3,600-square-foot custom home built by Weiss Building & Development LLC is the first home in Illinois certified to the DOE Challenge Home criteria, which requires that homes meet the EPA Indoor airPlus guidelines.The builder won a 2013 Housing Innovation Award in the custom builder category.

  10. Characterizing the occurrence, sources, and variability of radon in Pacific Northwest homes.

    Science.gov (United States)

    Turk, B H; Prill, R J; Grimsrud, D T; Moed, B A; Sextro, R G

    1990-04-01

    A compilation of data from earlier studies of 172 homes in the Pacific Northwest indicated that approximately 65 percent of the 46 homes tested in the Spokane River Valley/Rathdrum Prairie region of eastern Washington/northern Idaho had heating season indoor radon (222Rn) concentrations above the U. S. EPA guideline of 148 Bq m-3 (4 pCi L-1). A subset of 35 homes was selected for additional study. The primary source of indoor radon in the Spokane River Valley/Rathdrum Prairie was pressure-driven flow of soil gas containing moderate radon concentrations (geometric mean concentration of 16,000 Bq m-3) from the highly permeable soils (geometric mean permeability of 5 x 10(-11) m2) surrounding the house substructures. Estimated soil gas entry rates ranged from 0.4 to 39 m3h-1 and 1 percent to 21 percent of total building air infiltration. Radon from other sources, including domestic water supplies and building materials was negligible. In high radon homes, winter indoor levels averaged 13 times higher than summer concentrations, while in low radon homes winter levels averaged only 2.5 times higher. Short-term variations in indoor radon were observed to be dependent upon indoor-outdoor temperature differences, wind speed, and operation of forced-air furnace fans. Forced-air furnace operation, along with leaky return ducts and plenums, and openings between the substructure and upper floors enhanced mixing of radon-laden substructure air throughout the rest of the building.

  11. Characterizing the occurrence, sources, and variability of radon in pacific northwest homes

    International Nuclear Information System (INIS)

    Turk, B.H.; Prill, R.J.; Grimsrud, D.T.; Moed, B.A.; Sextro, R.G.

    1990-01-01

    A compilation of data from earlier studies of 172 homes in the Pacific Northwest indicated that approximately 65 percent of the 46 homes tested in the Spokane River Valley/Rathdrum Prairie region of eastern Washington/northern Idaho had heating season indoor radon ( 222 Rn) concentrations above the U.S. EPA guideline of 148 Bq m -3 (4 pCi L -1 ). A subset of 35 homes was selected for additional study. The primary source of indoor radon in the Spokane River Valley/Rathdrum Prairie was pressure-driven flow of soil gas containing moderate radon concentrations (geometric mean concentration of 16,000 Bq m -3 ) from the highly permeable soils (geometric mean permeability of 5 x 10 -11 m 2 ) surrounding the house substructures. Estimated soil gas entry rates ranged from 0.4 to 39 m 3 h -1 and 1 percent to 21 percent of total building air infiltration. Radon from other sources, including domestic water supplies and building materials was negligible. In high radon homes, winter indoor levels averaged 13 times higher than summer concentrations, while in low radon homes winter levels averaged only 2.5 times higher. Short-term variations in indoor radon were observed to be dependent upon indoor-outdoor temperature differences, wind speed, and operation of forced-air furnace fans. Forced-air furnace operations, along with leaky return ducts and plenums, and openings between the substructure and upper floors enhanced mixing of radon laden substructure air throughout the rest of the building

  12. DOE Zero Energy Ready Home Case Study: Amaris Homes, Afton Model

    Energy Technology Data Exchange (ETDEWEB)

    Pacific Northwest National Laboratory

    2017-09-01

    Amaris Homes built this 3,734-ft2 home in Afton, Minnesota, to the performance criteria of the DOE Zero Energy Ready Home (ZERH) program. A high-efficiency gas boiler provides hot water for the zoned radiant floor system as well as for faucets and showers. A high-efficiency heat pump provides zoned cooling.

  13. 78 FR 62462 - Regulation of Fuels and Fuel Additives: Modifications to Renewable Fuel Standard Program

    Science.gov (United States)

    2013-10-22

    ... renewable fuel is defined as fuel produced from renewable biomass that is used to replace or reduce the quantity of fossil fuel present in home heating oil or jet fuel.\\3\\ In essence, additional renewable fuel... of ``home heating oil.'' EPA determined that this term was ambiguous, and defined it by incorporating...

  14. Measure Guideline: Heat Pump Water Heaters in New and Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, C.; Puttagunta, S.; Owens, D.

    2012-02-01

    This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. This document is intended to explore the issues surrounding heat pump water heaters (HPWHs) to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs. Heat pump water heaters (HPWHs) promise to significantly reduce energy consumption for domestic hot water (DHW) over standard electric resistance water heaters (ERWHs). While ERWHs perform with energy factors (EFs) around 0.9, new HPWHs boast EFs upwards of 2.0. High energy factors in HPWHs are achieved by combining a vapor compression system, which extracts heat from the surrounding air at high efficiencies, with electric resistance element(s), which are better suited to meet large hot water demands. Swapping ERWHs with HPWHs could result in roughly 50% reduction in water heating energy consumption for 35.6% of all U.S. households. This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. While HPWHs promise to significantly reduce energy use for DHW, proper installation, selection, and maintenance of HPWHs is required to ensure high operating efficiency and reliability. This document is intended to explore the issues surrounding HPWHs to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs. Section 1 of this guideline provides a brief description of HPWHs and their operation. Section 2 highlights the cost and energy savings of HPWHs as well as the variables that affect HPWH performance, reliability, and efficiency. Section 3 gives guidelines for proper installation and maintenance of HPWHs, selection criteria for locating HPWHs, and highlights of important differences between ERWH and HPWH installations. Throughout this document, CARB has included results from the evaluation of 14 heat pump water heaters (including three recently released HPWH

  15. DOE Zero Energy Ready Home Case Study: Ithaca Neighborhood Housing Services, Ithaca, New York

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2013-10-01

    Eleven new townhomes comply with EPA's airPLUS criteria and use EPA WaterSense-qualifying features. Foundation walls are insulated on the exterior with XPS insulation. Non-shared walls use wall panels that were produced offsite. This builder was awarded a 2013 Housing Innovation Award in the affordable home category.

  16. How does a Swiss citizen want to heat his home?

    International Nuclear Information System (INIS)

    Stadelmann, M.

    2003-01-01

    This short article presents a summary of the results of representative market research carried out on which forms of energy are the most favoured in Switzerland. Solar energy is the form of energy at the top of the list of the most desired forms of energy for providing hot water. Natural gas is the energy carrier most favoured for space-heating, having for the first time overtaken solar energy in this sector. The article also quotes further findings of the survey, including the roles played by air pollution and other factors that influence energy desires. Also, the survey studied the sources used by the Swiss to obtain information on the subject of energy supply when building, buying or refurbishing their homes. The results are presented in the form of diagrams

  17. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2014-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 4 février de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org. * * * * * Carte de membre de l'Association du personnel du CERN Les membres GAC-EPA qui souhaitent recevoir une carte de membre AP en 2014 doivent  en faire la demande par email à secretariat@gac-epa.org, ou par lettre au secrétaire ...

  18. Short-term effects of instruction in home heating on indoor temperature and blood pressure in elderly people: a randomized controlled trial.

    Science.gov (United States)

    Saeki, Keigo; Obayashi, Kenji; Kurumatani, Norio

    2015-11-01

    Increased mortality from cardiovascular disease in winter is partly explained by increased blood pressure (BP) caused by cold exposure. For physicians, instruction in home heating is feasible option to reduce cold exposure, but the effectiveness remains unknown. To determine whether instruction in home heating increases indoor temperatures and decreases ambulatory BP among elderly people, we conducted an open-label, simply randomized, controlled trial in the winters. As an intervention, the participants were asked to set the heating device in the living room to start 1 h before estimated rising time with target temperature at 24°C, and to stay in the living room until 2 h after rising as long as possible. Repeatedly measured ambulatory BP, physical activity, and indoor temperatures until 4 h after rising were assessed using multilevel linear regression model with random intercept among individual. A total of 359 eligible participants (mean age ± standard deviation: 71.6 ± 6.6) were randomly allocated to the control group (n = 173) and intervention group (n = 186). Intervention significantly increased living room temperature by 2.09°C (95% confidence interval 1.28-2.90), and significantly decreased SBP and DBP by 4.43/2.33 mmHg (95% confidence interval 0.97-7.88/0.08-4.58 mmHg) after adjusting for confounders including age, sex, antihypertensive medication, household income, and physical activity. Short-term effect of instruction in home heating showed larger increase of indoor temperature than that of insulation intervention. Significant reduction of BPsuggests the effectiveness on preventing cardiovascular incidence in winter. To summarize, instruction in heating significantly decreased BP.

  19. "Slicer" for EPA

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    During the design of the Electron-Positron-Accumulator (EPA), there was an apprehension about the stability-limit of positron bunch-intensity in the SPS. In case that EPA would be able to produce bunches with intensities exceeding what the SPS could digest, an electrostatic septum was to slice up the EPA beam over 2 or 4 turns, thus lowering the bunch intensity while maintaining fast filling of LEP. The "slicer" septum was built and installed, but thanks to the good appetite of the SPS its use never became necessary. The slicer was removed from EPA to lower the machine impedance.

  20. An Investigation of the Design Potential of Thermochromic Home Textiles Used with Electric Heating Techniques

    Directory of Open Access Journals (Sweden)

    Hung-Jen Chen

    2015-01-01

    Full Text Available Thermochromic colorants have been developed since before the 1900s. There are a large number of patents in different applications of thermochromic textiles, but many innovations leave the field of aesthetic and functional textile design unexplored in the area of smart materials. This study aims to develop thermochromic home textiles that change colors and patterns by integrating thermochromic pigments and electric conductive yarns into textile structures. Stainless steel conductive yarns were sewed on textile substrates to enable heat generation to increase fabric temperature. The heat generation and temperature rise could be controlled by monitoring the voltage applied. The experiments of this study focused on analyzing electric resistance and heating properties of the conductive yarns and observing color changing time and color changing effects of the thermochromic textiles. By using the technique in this research, an image of “tai chi” was designed and implemented in a backlighting thermochromic fabric. It illustrates a range of opportunities for thermochromic textiles in new design research directions of Chinese calligraphy and traditional Chinese painting.

  1. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : le mardi 29 novembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  2. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2013-01-01

    Carte de membre de l'Association du personnel du CERN Comme cela a été précisé dans le bulletin d'automne n° 43, les membres GAC-EPA qui souhaitent recevoir une carte de membre AP en 2013 devront en faire la demande, avant le 31 janvier, par email à secretariat@gac-epa.org, ou par lettre au secrétaire du GAC-EPA, p/a Association du personnel CERN, CH-1211 GENEVE 23. Il n'y a pas de tacite reconduction de ces cartes et par conséquent une demande doit être faite chaque année par l'intéressé(e).

  3. Michigan: Healthy Homes-Healthy Business Project (A Former EPA CARE Project)

    Science.gov (United States)

    The Healthy Homes-Healthy Business project is a recipient of a Level II CARE cooperative agreement. The communities of focus for this CARE level II project are the adjacent neighborhoods of Southwest Detroit and South Dearborn.

  4. 75 FR 68781 - Workforce Guidelines for Home Energy Upgrades

    Science.gov (United States)

    2010-11-09

    ... as OSHA, EPA, the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE... circulation and the cumulative knowledge gathered throughout the 30-year history of the energy efficiency...

  5. ENERGY STAR Certified Non-AHRI Central Air Conditioner Equipment and Air Source Heat Pump

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Air Source Heat Pump and Central Air Conditioner Equipment that are effective as of September 15, 2015. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=airsrc_heat.pr_crit_as_heat_pumps Listed products have been submitted to EPA by ENERGY STAR partners that do not participate in the AHRI certification program. EPA will continue to update this list with products that are certified by EPA-recognized certification bodies other than AHRI. The majority of ENERGY STAR products, certified by AHRI, can be found on the CEE/AHRI Verified Directory at http://www.ceedirectory.org/

  6. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2015-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 1er décembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  7. EPA eXcats

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA eXcats is an enterprise-level data tracking application that provides management complaint tracking information for the EPA's Office of Civil Rights (OCR)...

  8. Electric heating guidelines: power smart home; 2. ed.

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    Guidelines, for use by B. C. Hydro, were established for proper planning and design of an electric heating system for residential buildings. The guidebook is divided into five sections: (1) comfort and electric heating systems, (2) contractors` guide to heat loss calculation, (3) imperial heat loss factors, (4) metric heat loss factors, and (5) installation guidelines for electric heating systems. Individual topics discussed include heat loss and the human body, heating systems and comfort, heat loss design, air leakage, and soil conductivity factors. Design considerations and equipment standards were described for the following electric heating systems: electric resistance baseboard systems, forced flow unitary heaters, electric radiant cable in-floor systems, radiant ceiling systems, forced warm air heating systems, furnaces, and heat pumps. 68 tabs., 29 figs.

  9. 24 CFR 3280.507 - Comfort heat gain.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Comfort heat gain. 3280.507 Section... gain. Information necessary to calculate the home cooling load shall be provided as specified in this part. (a) Transmission heat gains. Homes complying with this section shall meet the minimum heat loss...

  10. EPA Web Taxonomy

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPA's Web Taxonomy is a faceted hierarchical vocabulary used to tag web pages with terms from a controlled vocabulary. Tagging enables search and discovery of EPA's...

  11. GAC-EPA

    CERN Document Server

    GAC-EPA

    2013-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 1er octobre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 5 novembre et 3 décembre 2013. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  12. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : le mardi 1er novembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel. La permanence suivante aura lieu le mardi 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  13. GAC-EPA

    CERN Document Server

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 4 octobre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 1er et 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  14. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2015-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 3 novembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel La permanence suivante aura lieu le mardi 1er décembre 2015. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  15. EPA Linked Open Data (Collection)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is a collection item referencing the following EPA Linked Data resources: - EPA Facility Registry Service (FRS) - EPA Substance Registry Service (SRS) -...

  16. Home Performance with ENERGY STAR: Utility Bill Analysis on Homes Participating in Austin Energy's Program

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, D.; Mosey, G.; Plympton, P.; Dagher, L.

    2007-07-01

    Home Performance with ENERGY STAR (HPwES) is a jointly managed program of the U.S. Department of Energy (DOE) and the U.S. Environmental Protection Agency (EPA). This program focuses on improving energy efficiency in existing homes via a whole-house approach to assessing and improving a home's energy performance, and helping to protect the environment. As one of HPwES's local sponsors, Austin Energy's HPwES program offers a complete home energy analysis and a list of recommendations for efficiency improvements, along with cost estimates. To determine the benefits of this program, the National Renewable Energy Laboratory (NREL) collaborated with the Pacific Northwest National Laboratory (PNNL) to conduct a statistical analysis using energy consumption data of HPwES homes provided by Austin Energy. This report provides preliminary estimates of average savings per home from the HPwES Loan Program for the period 1998 through 2006. The results from this preliminary analysis suggest that the HPwES program sponsored by Austin Energy had a very significant impact on reducing average cooling electricity for participating households. Overall, average savings were in the range of 25%-35%, and appear to be robust under various criteria for the number of households included in the analysis.

  17. EPA Library Network Communication Strategies

    Science.gov (United States)

    To establish Agency-wide procedures for the EPA National Library Network libraries to communicate, using a range of established mechanisms, with other EPA libraries, EPA staff, organizations and the public.

  18. Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes - Business Case Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D [ORNL

    2007-05-01

    The long range strategic goal of the Department of Energy's Building Technologies (DOE/BT) Program is to create, by 2020, technologies and design approaches that enable the construction of net-zero energy homes at low incremental cost (DOE/BT 2005). A net zero energy home (NZEH) is a residential building with greatly reduced needs for energy through efficiency gains, with the balance of energy needs supplied by renewable technologies. While initially focused on new construction, these technologies and design approaches are intended to have application to buildings constructed before 2020 as well resulting in substantial reduction in energy use for all building types and ages. DOE/BT's Emerging Technologies (ET) team is working to support this strategic goal by identifying and developing advanced heating, ventilating, air-conditioning, and water heating (HVAC/WH) technology options applicable to NZEHs. Although the energy efficiency of heating, ventilating, and air-conditioning (HVAC) equipment has increased substantially in recent years, new approaches are needed to continue this trend. Dramatic efficiency improvements are necessary to enable progress toward the NZEH goals, and will require a radical rethinking of opportunities to improve system performance. The large reductions in HVAC energy consumption necessary to support the NZEH goals require a systems-oriented analysis approach that characterizes each element of energy consumption, identifies alternatives, and determines the most cost-effective combination of options. In particular, HVAC equipment must be developed that addresses the range of special needs of NZEH applications in the areas of reduced HVAC and water heating energy use, humidity control, ventilation, uniform comfort, and ease of zoning. In FY05 ORNL conducted an initial Stage 1 (Applied Research) scoping assessment of HVAC/WH systems options for future NZEHs to help DOE/BT identify and prioritize alternative approaches for further

  19. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 5 avril de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 3 mai, 7 juin, 6 septembre, 4 octobre, 1er et 29 novembre décembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  20. GAC-EPA

    CERN Document Server

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 3 mai de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 7 juin, 6 septembre, 4 octobre, 1er et 29 novembre décembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  1. GAC-EPA

    CERN Document Server

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 5 avril de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 3 mai, 7 juin, 6 septembre, 4 octobre, 1er et 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  2. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 1er mars de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 5 avril, 3 mai, 7 juin, 6 septembre, 4 octobre, 1er et 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  3. Effects of improved home heating on asthma in community dwelling children: randomised controlled trial.

    Science.gov (United States)

    Howden-Chapman, Philippa; Pierse, Nevil; Nicholls, Sarah; Gillespie-Bennett, Julie; Viggers, Helen; Cunningham, Malcolm; Phipps, Robyn; Boulic, Mikael; Fjällström, Pär; Free, Sarah; Chapman, Ralph; Lloyd, Bob; Wickens, Kristin; Shields, David; Baker, Michael; Cunningham, Chris; Woodward, Alistair; Bullen, Chris; Crane, Julian

    2008-09-23

    To assess whether non-polluting, more effective home heating (heat pump, wood pellet burner, flued gas) has a positive effect on the health of children with asthma. Randomised controlled trial. Households in five communities in New Zealand. 409 children aged 6-12 years with doctor diagnosed asthma. Installation of a non-polluting, more effective home heater before winter. The control group received a replacement heater at the end of the trial. The primary outcome was change in lung function (peak expiratory flow rate and forced expiratory volume in one second, FEV(1)). Secondary outcomes were child reported respiratory tract symptoms and daily use of preventer and reliever drugs. At the end of winter 2005 (baseline) and winter 2006 (follow-up) parents reported their child's general health, use of health services, overall respiratory health, and housing conditions. Nitrogen dioxide levels were measured monthly for four months and temperatures in the living room and child's bedroom were recorded hourly. Improvements in lung function were not significant (difference in mean FEV(1) 130.7 ml, 95% confidence interval -20.3 to 281.7). Compared with children in the control group, however, children in the intervention group had 1.80 fewer days off school (95% confidence interval 0.11 to 3.13), 0.40 fewer visits to a doctor for asthma (0.11 to 0.62), and 0.25 fewer visits to a pharmacist for asthma (0.09 to 0.32). Children in the intervention group also had fewer reports of poor health (adjusted odds ratio 0.48, 95% confidence interval 0.31 to 0.74), less sleep disturbed by wheezing (0.55, 0.35 to 0.85), less dry cough at night (0.52, 0.32 to 0.83), and reduced scores for lower respiratory tract symptoms (0.77, 0.73 to 0.81) than children in the control group. The intervention was associated with a mean temperature rise in the living room of 1.10 degrees C (95% confidence interval 0.54 degrees C to 1.64 degrees C) and in the child's bedroom of 0.57 degrees C (0.05 degrees C

  4. Field Evaluation of Highly Insulating Windows in the Lab Homes: Winter Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Graham B.; Widder, Sarah H.; Bauman, Nathan N.

    2012-06-01

    This field evaluation of highly insulating windows was undertaken in a matched pair of 'Lab Homes' located on the Pacific Northwest National Laboratory (PNNL) campus during the 2012 winter heating season. Improving the insulation and solar heat gain characteristics of a home's windows has the potential to significantly improve the home's building envelope and overall thermal performance by reducing heat loss (in the winter), and cooling loss and solar heat gain (in the summer) through the windows. A high quality installation and/or window retrofit will also minimize or reduce air leakage through the window cavity and thus also contribute to reduced heat loss in the winter and cooling loss in the summer. These improvements all contribute to decreasing overall annual home energy use. Occupant comfort (non-quantifiable) can also be increased by minimizing or eliminating the cold 'draft' (temperature) many residents experience at or near window surfaces that are at a noticeably lower temperature than the room air temperature. Lastly, although not measured in this experiment, highly insulating windows (triple-pane in this experiment) also have the potential to significantly reduce the noise transmittance through windows compared to standard double-pane windows. The metered data taken in the Lab Homes and data analysis presented here represent 70 days of data taken during the 2012 heating season. As such, the savings from highly insulating windows in the experimental home (Lab Home B) compared to the standard double-pane clear glass windows in the baseline home (Lab Home A) are only a portion of the energy savings expected from a year-long experiment that would include a cooling season. The cooling season experiment will take place in the homes in the summer of 2012, and results of that experiment will be reported in a subsequent report available to all stakeholders.

  5. Field Evaluation of Advances in Energy-Efficiency Practices for Manufactured Homes

    Energy Technology Data Exchange (ETDEWEB)

    Levy, E. [Advanced Residential Integrated Energy Solutions (ARIES) Collaboration, New York, NY (United States); Dentz, J. [Advanced Residential Integrated Energy Solutions (ARIES) Collaboration, New York, NY (United States); Ansanelli, E. [Advanced Residential Integrated Energy Solutions (ARIES) Collaboration, New York, NY (United States); Barker, G. [Advanced Residential Integrated Energy Solutions (ARIES) Collaboration, New York, NY (United States); Rath, P. [Advanced Residential Integrated Energy Solutions (ARIES) Collaboration, New York, NY (United States); Dadia, D. [Advanced Residential Integrated Energy Solutions (ARIES) Collaboration, New York, NY (United States)

    2016-03-01

    Three side-by-side lab houses were built, instrumented and monitored in an effort to determine through field testing and analysis the relative contributions of select technologies toward reducing energy use in new manufactured homes. The lab houses in Russellville, Alabama compared the performance of three homes built to varying levels of thermal integrity and HVAC equipment: a baseline HUD-code home equipped with an electric furnace and a split system air conditioner; an ENERGY STAR manufactured home with an enhanced thermal envelope and traditional split system heat pump; and a house designed to qualify for Zero Energy Ready Home designation with a ductless mini-split heat pump with transfer fan distribution system in place of the traditional duct system for distribution. Experiments were conducted in the lab houses to evaluate impact on energy and comfort of interior door position, window blind position and transfer fan operation. The report describes results of tracer gas and co-heating tests and presents calculation of the heat pump coefficient of performance for both the traditional heat pump and the ductless mini-split. A series of calibrated energy models was developed based on measured data and run in three locations in the Southeast to compare annual energy usage of the three homes.

  6. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2015-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 3 mars de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 7 avril, 5 mai, 2 juin, 1er septembre, 6 octobre, 3 novembre et 1er décembre 2013. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  7. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 2 février de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 1er mars, 5 avril, 3 mai, 7 juin, 6 septembre, 4 octobre, 1er et 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  8. Effect of home construction on indoor radon in Virginia and Maryland

    International Nuclear Information System (INIS)

    Mushrush, G.W.; Mose, D.G.

    1988-01-01

    The levels of indoor radon in approximately 500 homes located in two contiguous counties of northern Virginia and southern Maryland have been measured during four consecutive, three month seasonal intervals using alpha-track detectors. These two counties represent an area of about 700 square miles. Results from the winter period show that the indoor radon levels were about twice as high as anticipated. In some areas, more than 50% of the homes had winter indoor radon levels above 4 pCi/liter, the EPA's recommended action level. For the spring and fall periods, indoor radon levels showed a considerable drop with approximately 35% of the homes above 4 pCi/L. Summer values were even lower with approximately 25% of the homes above 4 pCi/L.Indoor radon can be related to the weather, but home construction demonstrably determines indoor radon levels

  9. EPA for Businesses and Non-Profits

    Science.gov (United States)

    Information and links to EPA web pages that are meant to help businesses and non-profits adhere to EPA regulations and otherwise protect the environment, take advantage of opportunities to collaborate with the EPA, and find training EPA training programs.

  10. EPA Administrative Enforcement Dockets

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA Administrative Enforcement Dockets database contains the electronic dockets for administrative penalty cases filed by EPA Regions and Headquarters. Visitors...

  11. US EPA Region 4 Brownfields

    Science.gov (United States)

    To improve public health and the environment, the United States Environmental Protection Agency (USEPA) collects information about facilities, sites, or places subject to environmental regulation or of environmental interest. Through the Geospatial Data Download Service, the public is now able to download the EPA Geodata shapefile containing facility and site information from EPA's national program systems. The file is Internet accessible from the Envirofacts Web site (https://www3.epa.gov/enviro/). The data may be used with geospatial mapping applications. (Note: The shapefile omits facilities without latitude/longitude coordinates.) The EPA Geospatial Data contains the name, location (latitude/longitude), and EPA program information about specific facilities and sites. In addition, the file contains a Uniform Resource Locator (URL), which allows mapping applications to present an option to users to access additional EPA data resources on a specific facility or site. This dataset shows Brownfields listed in the 2012 Facility Registry System.

  12. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 31 janvier de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 28 février, 28 mars, 25 avril, 30 mai, 29 août, 26 septembre, 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. e-mail : gac-epa@gac-epa.org.

  13. Climate change and health: Indoor heat exposure in vulnerable populations

    International Nuclear Information System (INIS)

    White-Newsome, Jalonne L.; Sánchez, Brisa N.; Jolliet, Olivier; Zhang, Zhenzhen; Parker, Edith A.; Timothy Dvonch, J.; O'Neill, Marie S.

    2012-01-01

    Introduction: Climate change is increasing the frequency of heat waves and hot weather in many urban environments. Older people are more vulnerable to heat exposure but spend most of their time indoors. Few published studies have addressed indoor heat exposure in residences occupied by an elderly population. The purpose of this study is to explore the relationship between outdoor and indoor temperatures in homes occupied by the elderly and determine other predictors of indoor temperature. Materials and methods: We collected hourly indoor temperature measurements of 30 different homes; outdoor temperature, dewpoint temperature, and solar radiation data during summer 2009 in Detroit, MI. We used mixed linear regression to model indoor temperatures' responsiveness to weather, housing and environmental characteristics, and evaluated our ability to predict indoor heat exposures based on outdoor conditions. Results: Average maximum indoor temperature for all locations was 34.85 °C, 13.8 °C higher than average maximum outdoor temperature. Indoor temperatures of single family homes constructed of vinyl paneling or wood siding were more sensitive than brick homes to outdoor temperature changes and internal heat gains. Outdoor temperature, solar radiation, and dewpoint temperature predicted 38% of the variability of indoor temperatures. Conclusions: Indoor exposures to heat in Detroit exceed the comfort range among elderly occupants, and can be predicted using outdoor temperatures, characteristics of the housing stock and surroundings to improve heat exposure assessment for epidemiological investigations. Weatherizing homes and modifying home surroundings could mitigate indoor heat exposure among the elderly.

  14. Waste-Heat-to-Power Market in the U.S., Heat is Power Annual Meeting (Presentation) – August 15, 2012

    Science.gov (United States)

    This presentation provides information about the EPA CHP Partnership, including an overview of the Partnership's tools and resources, and policy support. The presentation also describes the potential of Waste Heat to Power (WHP) systems.

  15. Michigan residential heating oil and propane price survey: 1995-1996 heating season. Final report

    International Nuclear Information System (INIS)

    Moriarty, C.

    1996-05-01

    This report summarizes the results of a survey of residential No. 2 distillate fuel (home heating oil) and liquefied petroleum gas (propane) prices over the 1995--1996 heating season in Michigan. The Michigan's Public Service Commission (MPSC) conducted the survey under a cooperative agreement with the US Department of Energy's (DOE) Energy Information Administration (EIA). This survey was funded in part by a grant from the DOE. From October 1995 through March 1996, the MPSC surveyed participating distributors by telephone for current residential retail home heating oil and propane prices. The MPSC transmitted the data via a computer modem to the EIA using the Petroleum Electronic Data Reporting Option (PEDRO). Survey results were published in aggregate on the MPSC World Wide Web site at http://ermisweb.state.mi.us/shopp. The page was updated with both residential and wholesale prices immediately following the transmission of the data to the EIA. The EIA constructed the survey using a sample of Michigan home heating oil and propane retailers. The sample accounts for different sales volumes, geographic location, and sources of primary supply

  16. Predictors of summertime heat index levels in New York City apartments.

    Science.gov (United States)

    Quinn, A; Kinney, P; Shaman, J

    2017-07-01

    During heat waves, fatal overexposure to heat most often occurs at home. It is not known how factors such as building size, floor level, and different types of air conditioning (AC) contribute to excess indoor heat. We monitored indoor temperature and humidity in 36 apartments in New York City during summers 2014 and 2015 and used these values to calculate the indoor heat index (HI). We investigated the role of AC type and building-level factors on indoor HI using multilevel regression models. Thirty-four of 36 homes had AC. Central and ductless AC types were associated with the coolest indoor conditions; homes with window and portable AC were significantly warmer. Apartments on the top floor of a building were significantly hotter during heat advisory periods than other apartments regardless of the presence of AC. High indoor HI levels persisted in some homes for approximately 1 day following the end of the two heat advisory periods. We provide concrete evidence of higher heat levels in top floor apartments and in homes with certain types of AC. High heat levels that persist indoors after outdoor heat has subsided may present an underappreciated public health risk. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Residential solar-heating system

    Science.gov (United States)

    1978-01-01

    Complete residential solar-heating and hot-water system, when installed in highly-insulated energy-saver home, can supply large percentage of total energy demand for space heating and domestic hot water. System which uses water-heating energy storage can be scaled to meet requirements of building in which it is installed.

  18. Initial Business Case Analysis of Two Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D [ORNL

    2006-11-01

    The long range strategic goal of the Department of Energy's Building Technologies (DOE/BT) Program is to create, by 2020, technologies and design approaches that enable the construction of net-zero energy homes at low incremental cost (DOE/BT 2005). A net zero energy home (NZEH) is a residential building with greatly reduced needs for energy through efficiency gains, with the balance of energy needs supplied by renewable technologies. While initially focused on new construction, these technologies and design approaches are intended to have application to buildings constructed before 2020 as well resulting in substantial reduction in energy use for all building types and ages. DOE/BT's Emerging Technologies (ET) team is working to support this strategic goal by identifying and developing advanced heating, ventilating, air-conditioning, and water heating (HVAC/WH) technology options applicable to NZEHs. Although the energy efficiency of heating, ventilating, and air-conditioning (HVAC) equipment has increased substantially in recent years, new approaches are needed to continue this trend. Dramatic efficiency improvements are necessary to enable progress toward the NZEH goals, and will require a radical rethinking of opportunities to improve system performance. The large reductions in HVAC energy consumption necessary to support the NZEH goals require a systems-oriented analysis approach that characterizes each element of energy consumption, identifies alternatives, and determines the most cost-effective combination of options. In particular, HVAC equipment must be developed that addresses the range of special needs of NZEH applications in the areas of reduced HVAC and water heating energy use, humidity control, ventilation, uniform comfort, and ease of zoning. In FY05 ORNL conducted an initial Stage 1 (Applied Research) scoping assessment of HVAC/WH systems options for future NZEHs to help DOE/BT identify and prioritize alternative approaches for further

  19. The Pacific Northwest residential consumer: Perceptions and preferences of home heating fuels, major appliances, and appliance fuels

    Energy Technology Data Exchange (ETDEWEB)

    Harkreader, S.A.; Hattrup, M.P.

    1988-09-01

    In 1983 the Bonneville Power Administration contracted with the Pacific Northwest Laboratory (PNL) to conduct an analysis of the marketing environment for Bonneville's conservation activities. Since this baseline residential study, PNL has conducted two follow up market research projects: Phase 2 in 1985, and Phase 3, in 1988. In this report the respondents' perceptions, preferences, and fuel switching possibilities of fuels for home heating and major appliances are examined. To aid in effective target marketing, the report identifies market segments according to consumers' demographics, life-cycle, attitudes, and opinions.

  20. EPA's Information Architecture and Web Taxonomy

    Science.gov (United States)

    EPA's Information Architecture creates a topical organization of our website, instead of an ownership-based organization. The EPA Web Taxonomy allows audiences easy access to relevant information from EPA programs, by using a common vocabulary.

  1. US EPA Region 4 RMP Facilities

    Science.gov (United States)

    To improve public health and the environment, the United States Environmental Protection Agency (USEPA) collects information about facilities, sites, or places subject to environmental regulation or of environmental interest. Through the Geospatial Data Download Service, the public is now able to download the EPA Geodata shapefile containing facility and site information from EPA's national program systems. The file is Internet accessible from the Envirofacts Web site (http://www.epa.gov/enviro). The data may be used with geospatial mapping applications. (Note: The shapefile omits facilities without latitude/longitude coordinates.) The EPA Geospatial Data contains the name, location (latitude/longitude), and EPA program information about specific facilities and sites. In addition, the file contains a Uniform Resource Locator (URL), which allows mapping applications to present an option to users to access additional EPA data resources on a specific facility or site.

  2. Phased Retrofits in Existing Homes in Florida Phase II: Shallow Plus Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, K. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Parker, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Martin, E. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Chasar, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Amos, B. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)

    2016-02-03

    The BAPIRC team and Florida Power and Light (FPL) electric utility pursued a pilot phased energy-efficiency retrofit program in Florida by creating detailed data on the energy and economic performance of two levels of retrofit - simple and deep. For this Phased Deep Retrofit (PDR) project, a total of 56 homes spread across the utility partner's territory in east central Florida, southeast Florida, and southwest Florida were instrumented between August 2012 and January 2013, and received simple pass-through retrofit measures during the period of March 2013 - June 2013. Ten of these homes received a deeper package of retrofits during August 2013 - December 2013. A full account of Phase I of this project, including detailed home details and characterization, is found in Parker et al, 2015 (currently in draft). Phase II of this project, which is the focus of this report, applied the following additional retrofit measures to select homes that received a shallow retrofit in Phase I: a) Supplemental mini-split heat pump (MSHP) (6 homes); b) Ducted and space coupled Heat Pump Water Heater (8 homes); c) Exterior insulation finish system (EIFS) (1 homes); d) Window retrofit (3 homes); e) Smart thermostat (21 homes: 19 NESTs; 2 Lyrics); f) Heat pump clothes dryer (8 homes); g) Variable speed pool pump (5 homes).

  3. Translating exercise interventions to an in-home setting for seniors: preliminary impact on physical activity and function.

    Science.gov (United States)

    Dondzila, Christopher J; Swartz, Ann M; Keenan, Kevin G; Harley, Amy E; Azen, Razia; Strath, Scott J

    2016-12-01

    The purpose of this study is to investigate whether an in-home, individually tailored intervention is efficacious in promoting increases in physical activity (PA) and improvements in physical functioning (PF) in low-active older adults. Participants were randomized to two groups for the 8-week intervention. The enhanced physical activity (EPA) group received individualized exercise programming, including personalized step goals and a resistance band training program, and the standard of care (SoC) group received a general activity goal. Pre- and post-intervention PF measures included choice step reaction time, knee extension/flexion strength, hand grip strength, and 8 ft up and go test completion time. Thirty-nine subjects completed this study (74.6 ± 6.4 years). Significant increases in steps/day were observed for both the EPA and SoC groups, although the improvements in the EPA group were significantly higher when including only those who adhered to weekly step goals. Both groups experienced significant PF improvements, albeit greater in the EPA group for the 8 ft up and go test and knee extension strength. A low cost, in-home intervention elicited improvements in both PA and PF. Future research is warranted to expand upon the size and scope of this study, exploring dose thresholds (and time frames) for PA to improve PF and strategies to further bolster adherence rates to maximize intervention benefits.

  4. EPA scientific integrity policy draft

    Science.gov (United States)

    Showstack, Randy

    2011-08-01

    The U.S. Environmental Protection Agency (EPA) issued its draft scientific integrity policy on 5 August. The draft policy addresses scientific ethical standards, communications with the public, the use of advisory committees and peer review, and professional development. The draft policy was developed by an ad hoc group of EPA senior staff and scientists in response to a December 2010 memorandum on scientific integrity from the White House Office of Science and Technology Policy. The agency is accepting public comments on the draft through 6 September; comments should be sent to osa.staff@epa.gov. For more information, see http://www.epa.gov/stpc/pdfs/draft-scientific-integrity-policy-aug2011.pdf.

  5. US EPA overview

    International Nuclear Information System (INIS)

    Rowe, W.D.

    1976-01-01

    EPA believes that effective and efficient solutions to problems in all radioactive waste disposal areas will require close coordination and cooperation among all agencies involved. In this regard, EPA already has participated in meetings with the Energy Research and Development Administration, the Nuclear Regulatory Commission, the Council on Environmental Quality, the U.S. Geological Survey, and the Office of Management and Budget to lay the groundwork for the development of a consolidated national radioactive waste disposal plan. The EPA program is directed first toward developing goals and requirements; and then, in cooperation with the public, industry, the States and Federal agencies, towards determining by what means these goals can be achieved for each waste management option. In addition, the program will develop criteria for determining when the goals of the waste management options have been achieved. In summary, EPA will provide fundamental environmental criteria and generally applicable environmental standards for permanent disposal of high level radwastes. Concurrently, ERDA will develop the necessary technology; and NRC will conduct necessary studies, develop waste-related regulations, and license specific sites and methods of control. Together, we will be able to manage the disposal of the Nation's radioactive waste in an environmentally adequate manner

  6. EPA perspective on federal facility agreements

    International Nuclear Information System (INIS)

    Grundler, C.

    1988-01-01

    Although DOE's image with Congress and the media concerning environmental compliance may be poor, EPA sees the Department's recent attitude toward the environment as good. DOE and EPA must continue to move forward. In particular, EPA would like to emphasize less study of a problem and more clean-up. Strong, enforceable agreements will allow this goal to be met by letting EPA take more risks in its decision making. Currently EPA is developing an enforcement strategy for Federal facilities. This strategy will address identifying Federal facilities of concern, increasing enforcement and compliance monitoring activities at those facilities, implementing the model agreements, resource planning, and the establishment of an Agency Management System for Federal facilities. There are over 1000 Federal facilities which are listed on the EPA compliance docket. Over 200 Federal facilities are expected to be included on the NPL. Increased EPA attention may increase the ability of the various Federal agencies to obtain the necessary funding. Another subject being addressed by EPA is the liability of government contractors under the environmental statutes. The Agency is developing a GoCo enforcement strategy. In the hazardous waste enforcement program, three criteria are being considered for determining when to proceed against a contractor: Degree of contractor control over the hazardous waste management activity. Who is actually performing the work, and Degree of Departmental cooperation

  7. What is consumer behaviour? Technical and behaviour oriented models with regard to home heating energy consumption; Was ist Nutzerverhalten? Technische und verhaltensorientierte Sichtweisen am Beispiel des Heizenergieverbrauchs von Wohngebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Casties, M.

    2000-07-01

    The lecture presents various approaches to describe and analyze consumer behaviour with regard to home heating energy consumption. Models from both a technical as well as an economic, socio-economic and psychological perspective are taken into consideration. The possibilities and problems of these approaches in forcasting heating energy consumption are discussed. (orig.)

  8. Energy Saver: Tips on Saving Money & Energy at Home

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-09-01

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  9. Energy Savers: Tips on Saving Money & Energy at Home

    Energy Technology Data Exchange (ETDEWEB)

    None

    2011-12-01

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  10. Energy Savers: Tips on Saving Money & Energy at Home

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-05-01

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  11. Energy Savers Tips on Saving Energy& Money at Home

    Energy Technology Data Exchange (ETDEWEB)

    2003-06-01

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances

  12. Household electricity and gas consumption for heating homes

    International Nuclear Information System (INIS)

    Jeong, Jaehoon; Seob Kim, Chang; Lee, Jongsu

    2011-01-01

    Energy consumption has been drastically changed because of energy source depletion, price fluctuations, development and penetration of alternative energy sources, and government policies. Household energy sources are interrelated, and energy price and household characteristics, such as income level and dwelling size, affect the usage. To supply energy consistently and achieve a balance between production and consumption, stakeholders must understand consumer energy-consumption behavior. Therefore, this study identifies household heating energy usage patterns and the substitutive and/or complementary relationships between electricity and gas. Based on a multiple discrete-continuous extreme value model, household utility structure is identified from data on gas-heating usage. Results show greater utility and the smallest satiation values for gas boilers than for electric heaters and electric heating beds. The effects of consumer socioeconomic and environmental characteristics on the choice of heating energy sources were analyzed. Also, for further comparison, the respondents were split into high and low categories for income, heating degree days, dwelling size, and gas usage. Gas was found to be the most economical heating choice for households. - Research highlights: → This study investigates household electricity and gas consumption behavior for heating. → It also studied the relationship between two energy sources. → A research framework is suggested by combining the CDA and the MDCEV models. → It provides quantitative data that might be used for designing efficient energy policies.

  13. A Fleet of Low-Cost Sensor Based Air Quality Monitors Is Used to Measure Carbon Dioxide and Carbon Monoxide in Two Settings: In the Ambient Environment to Explore the Regional-Scale Spatial Variability of These Compounds Via a Distributed Network, and in Homes to Investigate How Heating during Winter Months can Impact Indoor Air Quality.

    Science.gov (United States)

    Casey, J. G.; Hannigan, M.; Collier, A. M.; Coffey, E.; Piedrahita, R.

    2016-12-01

    Affordable, small, portable, quiet tools to measure atmospheric trace gases and air quality enable novel experimental design and new findings. Members of the Hannigan Lab at the University of Colorado in Boulder have been working over the last few years to integrate emerging affordable gas sensors into such an air quality monitor. Presented here are carbon monoxide (CO) and carbon dioxide (CO2) measurements from two field experiments that utilized these tools. In the first experiment, ten air quality monitors were located northeast of Boulder throughout the Denver Julesburg oil and gas basin. The Colorado Department of Health and Environment has several air quality monitoring sites in this broader region, each in an Urban center. One goal of the experiment was to determine whether or not significant spatial variability of EPA criteria pollutants like CO, exists on a sub-regulatory monitoring grid scale. Another goal of the experiment was to compare rural sampling locations with urban sites. The monitors collected continuous data (sampling every 15 seconds) at each location over the course of several months. Our sensor calibration procedures are presented along with our observations and an analysis of the spatial and temporal variability in CO and CO2. In the second experiment, we used eight of our air quality monitors to better understand how home heating fuel type can impact indoor air quality in two communities on the Navajo Nation. We sought to compare air quality in homes using one of four different fuels for heat (wood, wood plus coal, pellet, and gas). There are many factors that contribute to indoor air quality and the impact of an emission source, like a woodstove, within a home. Having multiple, easily deployable, air quality monitors allowed us to account for many of these factors. We sampled four homes at a time, aiming for one home from each of our fuel groups in each sampling period. We sampled inside and outside of each home for a period of 3-4 days

  14. DOE Zero Energy Ready Home Case Study: Nexus EnergyHomes, Frederick, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2013-09-01

    This urban infill community with 24 duplexes, 19 townhomes, and 7 single-family homes features SIP walls, geothermal heat pumps, solar PV, and a proprietary energy management system. The builder won a 2013 Housing Innovation Award in the production builder category.

  15. Experiments Demonstrate Geothermal Heating Process

    Science.gov (United States)

    Roman, Harry T.

    2012-01-01

    When engineers design heat-pump-based geothermal heating systems for homes and other buildings, they can use coil loops buried around the perimeter of the structure to gather low-grade heat from the earth. As an alternative approach, they can drill well casings and store the summer's heat deep in the earth, then bring it back in the winter to warm…

  16. Open Letter from the GAC-EPA to the Chairman of the PFGB EPA

    CERN Multimedia

    GAC-EPA

    2012-01-01

    Following the publication by the Chairman of the Pension Fund Governing Board of  the Spring report of the Pension Fund in the CERN Bulletin issue dated 25 July 2012 (Nos 30 & 31), the GAC-EPA has reacted through an open letter. See www.gac-epa.org under Announcement.

  17. In the Hot Seat--Analyzing Your Heating Options

    Science.gov (United States)

    Palliser, Janna

    2011-01-01

    When winter rolls around, keeping yourself and your home warm is of the utmost importance. Heating your home seems like a simple subject to tackle, but there are many heating systems available, requiring different fuels, installations, and costs. The various fuel types and their environmental footprints will be the focus of this month's column.…

  18. Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders

    Energy Technology Data Exchange (ETDEWEB)

    Kerrigan, P. [Building Science Corporation, Somerville, MA (United States); Loomis, H. [Building Science Corporation, Somerville, MA (United States)

    2014-09-01

    The purpose of this project was to evaluate integrated packages of advanced measures in individual test homes to assess their performance with respect to Building America program goals, specifically compliance with the DOE Challenge Home Program. BSC consulted on the construction of five test houses by three cold climate production builders in three U.S. cities and worked with the builders to develop a design package tailored to the cost-related impacts for each builder. Also, BSC provided support through performance testing of the five test homes. Overall, the builders have concluded that the energy related upgrades (either through the prescriptive or performance path) represent reasonable upgrades. The builders commented that while not every improvement in specification was cost effective (as in a reasonable payback period), many were improvements that could improve the marketability of the homes and serve to attract more energy efficiency discerning prospective homeowners. However, the builders did express reservations on the associated checklists and added certifications. An increase in administrative time was observed with all builders. The checklists and certifications also inherently increase cost due to: adding services to the scope of work for various trades, such as HERS Rater, HVAC contractor; and increased material costs related to the checklists, especially the EPA Indoor airPLUS and EPA WaterSense® Efficient Hot Water Distribution requirement.

  19. Wood as a home heating fuel

    International Nuclear Information System (INIS)

    Wood, K.

    1991-01-01

    This article describes the development of clean-burning technology in three types of wood-burning appliances: catalytic, non-catalytic, and pellet stoves. A recent study by the Washington State Energy Extension Office concluded that in homes that use both electricity and wood, 73 megawatts of electricity/yr were saved by using wood. Since wood-burning stoves can now meet air quality standards, wood could be considered to be a greenhouse-neutral fuel if more trees are planted as they are consumed

  20. Cheminformatics Analysis of EPA ToxCast Chemical Libraries ...

    Science.gov (United States)

    An important goal of toxicology research is the development of robust methods that use in vitro and chemical structure information to predict in vivo toxicity endpoints. The US EPA ToxCast program is addressing this goal using ~600 in vitro assays to create bioactivity profiles on a set of 320 compounds, mostly pesticide actives, that have well characterized in vivo toxicity. These 320 compounds (EPA-320 set evaluated in Phase I of ToxCast) are a subset of a much larger set of ~10,000 candidates that are of interest to the EPA (called here EPA-10K). Predictive models of in vivo toxicity are being constructed from the in vitro assay data on the EPA-320 chemical set. These models require validation on additional chemicals prior to wide acceptance, and this will be carried out by evaluating compounds from EPA-10K in Phase II of ToxCast. We have used cheminformatics approaches including clustering, data visualization, and QSAR to develop models for EPA-320 that could help prioritizing EPA-10K validation chemicals. Both chemical descriptors, as well as calculated physicochemical properties have been used. Compounds from EPA-10K are prioritized based on their similarity to EPA-320 using different similarity metrics, with similarity thresholds defining the domain of applicability for the predictive models built for EPA-320 set. In addition, prioritized lists of compounds of increasing dissimilarity from the EPA-320 have been produced, to test the ability of the EPA-320

  1. Building heating technology in Smart Home using PI System management tools

    Directory of Open Access Journals (Sweden)

    Jan Vanus

    2016-03-01

    Full Text Available For comfortable remote monitoring of some operational and technical functions inside own Smart Home building, it is possible to use a lot of useful programmes and tools. However, not each programme or tool is suited to this purpose, or it does not offer required functionality. The aim of this paper is to describe using an appropriate software tool of PI System for a real-time monitoring of acquired data from real technology parts located at a training centre of the Moravian-Silesian Wood Cluster. Then a superior system including applications of PI Coresight and PI ProcessBook is used for analysis and processing of these acquired data (e.g. by using the Dynamic Time Warping method for specific technological quantities. Each application has own advantages and disadvantages, which are evaluated in conjunction with possibilities of manipulating the data. In an experimental part, there are also applied a technological communication standard of BACnet to controlling heating, cooling and forced ventilation, and a software tool of DESIGO Insight for visualising the data in forms of tables, multi-layer graphs, and screens for a certain technology.

  2. EPA Communications Stylebook: Writing Guide

    Science.gov (United States)

    For the most part, EPA follows the Associated Press (AP) Stylebook. Other requirements of basic punctuation and grammar and usage in EPA writing modify, supplement, or in some cases reiterate AP style.

  3. Housing improvement and home safety Effectiveness Matters

    OpenAIRE

    , Crd; Sphr@, L; , MrcSphsu

    2014-01-01

    The homes we live in impact on health, wellbeing and health inequalities. Treating illnesses directly related to living in cold, damp and dangerous homes costs the NHS £2.5 billion per year. Ensuring affordable warmth through insulation and more efficient heating can improve health and wellbeing. Home safety assessment and modification can reduce falls and risk of falling in older people. Education, promotion of exercise and wearing of appropriate footwear, environmental modifications and tra...

  4. EPA Alternative Dispute Resolution Contacts

    Science.gov (United States)

    The success of EPA's ADR efforts depends on a network of talented and experienced professionals in Headquarters offices and EPA Regions. For Agency-wide ADR information, please contact the Conflict Prevention and Resolution Center.

  5. Use of Low Level of Continuous Heat as an Adjunct to Physical Therapy Improves Knee Pain Recovery and the Compliance for Home Exercise in Patients With Chronic Knee Pain: A Randomized Controlled Trial.

    Science.gov (United States)

    Petrofsky, Jerrold S; Laymon, Michael S; Alshammari, Faris S; Lee, Haneul

    2016-11-01

    Petrofsky, JS, Laymon, MS, Alshammari, FS, and Lee, H. Use of low level of continuous heat as an adjunct to physical therapy improves knee pain recovery and the compliance for home exercise in patients with chronic knee pain: a randomized controlled trial. J Strength Cond Res 30(11): 3107-3115, 2016-This study examined if the use of low level continuous heat (LLCH) wraps at home between physical therapy sessions at a clinic resulted in better therapy outcomes in patients with chronic knee pain. Fifty individuals with chronic nonspecific knee pain was randomly allocated to 2 groups: the LLCH group and the placebo group. All subjects underwent 1 hour of conventional physical therapy twice per week for 2 weeks at the outpatient clinic and they were asked to accomplish 1 hour of therapeutic exercise at home each day between sessions. The LLCH group applied LLCH knee wraps for 6 hours at home before home exercise while placebo group took a placebo ibuprofen. (This was done since placebo heat is impossible to use since subjects would notice that the wraps were cold) Before, during, and after intervention, pain intensity, active range of motion of the knee (AROM), knee strength, and home exercise compliance were measured. The LLCH group showed pain attenuation after 2 weeks of therapy sessions (p ≤ 0.05). AROM and strength of the knee significantly improved over time compared to the placebo group. Home exercise compliance was significantly higher in the LLCH group than placebo group (p ≤ 0.05). These results indicated that the use of LLCH as an adjunct to conventional physical therapy for chronic knee pain significantly improved pain attenuation and recovery of strength and movement in patients with chronic knee pain.

  6. Analyzing Design Heating Loads in Superinsulated Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Arena, Lois [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2015-06-01

    Super-insulated homes offer many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the building envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. During the winter of 2013/2014, CARB monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for super insulated homes.

  7. DOE ZERH Case Study: Evolutionary Home Builders, The Adaptation Home, Geneva, IL

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2015-09-01

    Case study of a DOE 2015 Housing Innovation Award winning custom home in the cold climate that got a HERS 30 without PV, with 2x8 24” on center walls with blown fiberglass and 4” polysio rigid foam; basement with 2” XPS interior, 4” under slab, 4” exterior of foundation wall; vented attic with R-100 blown cellulose; wo air-to-air heat pumps SEER 14.1; HSPF 9.6; heat pump water heater.

  8. Electron-Positron Accumulator (EPA)

    CERN Multimedia

    Photographic Service

    1986-01-01

    After acceleration in the low-current linac LIL-W, the electrons and positrons are accumulated in EPA to obtain a sufficient intensity and a suitable time-structure, before being passed on to the PS for further acceleration to 3.5 GeV. Electrons circulate from right to left, positrons in the other direction. Dipole bending magnets are red, focusing quadrupoles blue, sextupoles for chromaticity-control orange. The vertical tube at the left of the picture belongs to an optical transport system carrying the synchrotron radiation to detectors for beam size measurement. Construction of EPA was completed in spring 1986. LIL-W and EPA were conceived for an energy of 600 MeV, but operation was limited to 500 MeV.

  9. 24 CFR 3280.707 - Heat producing appliances.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Heat producing appliances. 3280.707... Systems § 3280.707 Heat producing appliances. (a) Heat-producing appliances and vents, roof jacks and... appliance, the heating appliance shall be installed by the manufacturer of the manufactured home in...

  10. Locations of Combined Sewer Overflow Outfalls - US EPA Region 3

    Science.gov (United States)

    This data layer identifies the locations of Combined sewer overflow outfalls. Combined sewer systems are sewers that are designed to collect rainwater runoff, domestic sewage, and industrial wastewater in the same pipe. Most of the time, combined sewer systems transport all of their wastewater to a sewage treatment plant, where it is treated and then discharged to a water body. During periods of heavy rainfall or snowmelt, however, the wastewater volume in a combined sewer system can exceed the capacity of the sewer system or treatment plant. For this reason, combined sewer systems are designed to overflow occasionally and discharge excess untreated wastewater directly to nearby streams, rivers, or other water bodies. For further information visit: http://cfpub1.epa.gov/npdes/home.cfm?program_id=5

  11. How does a Swiss citizen want to heat his home?; Wie will der Schweizer heizen ?

    Energy Technology Data Exchange (ETDEWEB)

    Stadelmann, M

    2003-07-01

    This short article presents a summary of the results of representative market research carried out on which forms of energy are the most favoured in Switzerland. Solar energy is the form of energy at the top of the list of the most desired forms of energy for providing hot water. Natural gas is the energy carrier most favoured for space-heating, having for the first time overtaken solar energy in this sector. The article also quotes further findings of the survey, including the roles played by air pollution and other factors that influence energy desires. Also, the survey studied the sources used by the Swiss to obtain information on the subject of energy supply when building, buying or refurbishing their homes. The results are presented in the form of diagrams.

  12. Heat transmission systems for heating and potable water. New requirements and problem solutions for hygiene, safety and improved heat utilization. Waermeuebertragungssysteme fuer Heizung und Trinkwasser. Neue Anforderungen und Problemloesungen bezueglich Hygiene, Sicherheit und besserer Waermenutzung

    Energy Technology Data Exchange (ETDEWEB)

    Kremer, R

    1989-10-01

    In the past, additional demands were made on heat transmission systems regarding hygienic requirements in potable water heating plant for hospitals, hotels, sanatoriums and old-age homes, safety requirements to protect the potable water from the penetration of hazardous substances and requirements for improved heat utilization through return flow cooling and condensate cooling in the district heating. Where potable water heaters are concerned, safety radiators for heat transfer which comply with the requirements of DIN 1988 Part 2 and Part 4, as well as water heaters with permanent disinfection which are legionnaires' disease-proof, are now available for use in hospitals, old age homes and sanatoriums. For the district heating sector, improved range systems with low concentration in the hot water sector as well as condensate heat utilizing systems have been further developed in the steam heating sector. (orig.).

  13. Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders

    Energy Technology Data Exchange (ETDEWEB)

    Kerrigan, P.; Loomis, H.

    2014-09-01

    The purpose of this project was to evaluate integrated packages of advanced measures in individual test homes to assess their performance with respect to Building America Program goals, specifically compliance with the DOE Challenge Home Program. BSC consulted on the construction of five test houses by three Cold Climate production builders in three separate US cities. BSC worked with the builders to develop a design package tailored to the cost-related impacts for each builder. Therefore, the resulting design packages do vary from builder to builder. BSC provided support through this research project on the design, construction and performance testing of the five test homes. Overall, the builders have concluded that the energy related upgrades (either through the prescriptive or performance path) represent reasonable upgrades. The builders commented that while not every improvement in specification was cost effective (as in a reasonable payback period), many were improvements that could improve the marketability of the homes and serve to attract more energy efficiency discerning prospective homeowners. However, the builders did express reservations on the associated checklists and added certifications. An increase in administrative time was observed with all builders. The checklists and certifications also inherently increase cost due to: 1. Adding services to the scope of work for various trades, such as HERS Rater, HVAC contractor; 2. Increased material costs related to the checklists, especially the EPA Indoor airPLUS and EPA WaterSense(R) Efficient Hot Water Distribution requirement.

  14. The possibilities of heat pumps utilisation for family houses and flats fumigation

    Directory of Open Access Journals (Sweden)

    Ján Pinka

    2006-10-01

    Full Text Available Heat pumps (HPs with the help of electricity use a renewable energy source to supply heat for homes or industrial buildings and to heat tap water. HP is a heating unit that will provide us with heat for our home for some 20 to 30 years to come and has a potential to replace traditional heating systems powered by gas, oil or coal. At this time, there is no other heating system that supplies clean heat with the help of up to 80 per cent of the renewable solar energy during all year.

  15. EPA program to demonstrate mitigation measures for indoor radon: initial results

    International Nuclear Information System (INIS)

    Henschel, D.B.; Scott, A.G.

    1986-01-01

    EPA has installed radon mitigation techniques in 18 concrete block basement homes in the Reading Prong region of eastern Pennsylvania. Three alternative active soil ventilation approaches were tested: suction on the void network within the concrete block basement walls; suction on the footing drain tile system; and suction on the aggregate underneath the concrete slab. The initial 18 mitigation installations were designed to demonstrate techniques which would have low to moderate installation and operating costs. Where effective closure of major openings in the block walls is possible, suction on the wall voids has proved to be extremely effective, able to reduce homes having very high radon Working Levels (up to 7 WL) to 0.02 WL and less. However, where inaccessible major openings are concealed within the wall, it is more difficult and/or more expensive to develop adequate suction on the void network, and performance is reduced. Testing is continuing to demonstrate the steps required to achieve high performance with wall suction in homes with such difficult-to close walls. Drain tile suction can be very effective where the drain tiles completely surround the home; drain tile suction is the least expensive and most aesthetic of the active soil ventilation approaches, but appears susceptible to spikes in radon levels when the basement is depressurized. Sub-slab suction as tested in this study - with one or two individual suction points in the slab - does not appear adequate to ensure sustained high levels of reduction on block wall basement homes; it appears to effectively treat slab-related soil gas entry routes so long as a uniform layer of aggregate is present, but it does not appear to effectively treat the wall-related entry routes. Closure of major openings might have improved sub-slab suction performance. 5 figures, 3 tables

  16. EPA Metadata Style Guide Keywords and EPA Organization Names

    Science.gov (United States)

    The following keywords and EPA organization names listed below, along with EPA’s Metadata Style Guide, are intended to provide suggestions and guidance to assist with the standardization of metadata records.

  17. End-of-season heating fuel report

    International Nuclear Information System (INIS)

    1992-01-01

    The year-end report notes that the 1991-92 heating season had lower average oil prices (retail home heating fuel) than the past two winters and prices remained relatively stable throughout the season. This year, the heating season average was $.87 per gallon, $1.05 for kerosene, and $1.33 for propane

  18. Super Energy Efficient Design (S.E.E.D.) Home Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    German, A. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Dakin, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Backman, C. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Weitzel, E. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Springer, D. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2012-12-01

    This report describes the results of evaluation by the Alliance for Residential Building Innovation (ARBI) Building America team of the “Super Energy Efficient Design” (S.E.E.D) home, a 1,935 sq. ft., single-story spec home located in Tucson, AZ. This prototype design was developed with the goal of providing an exceptionally energy efficient yet affordable home and includes numerous aggressive energy features intended to significantly reduce heating and cooling loads such as structural insulated panel (SIP) walls and roof, high performance windows, an ERV, an air-to-water heat pump with mixed-mode radiant and forced air delivery, solar water heating, and rooftop PV. Source energy savings are estimated at 45% over the Building America B10 Benchmark. System commissioning, short term testing, long term monitoring and detailed analysis of results was conducted to identify the performance attributes and cost effectiveness of the whole house measure package.

  19. Information work: solar energy. Home heating, hot water production, cooling, power generation. Volume 1. Informationswerk sonnenenergie. Hausheizung, warmwasserbereitung, kuehlung, stromgewinnung. Band 1

    Energy Technology Data Exchange (ETDEWEB)

    1976-01-01

    Seven articles on various aspects of solar energy utilization are compiled. The topics discussed are solar home heating in modular construction, recommedations for private and industrial new construction, legal aspects in solar energy installations, solar state diagrams as an aid for improving solar planning data for construction, insolation and clouds, network of stations and observation sites for radiation measurements in Germany, and solar collectors for air medium. (JSR)

  20. In-home performance of residential cordwood stoves

    International Nuclear Information System (INIS)

    Houck, J.E.; Barnett, S.G.; Roholt, R.B.

    1991-01-01

    The air quality impacts of residential cordwood stoves have been of concern to regulators, energy planners, and members of the woodstove industry. In addition, the reliability of laboratory certification emission values in predicting 'real world' emissions has been questioned. In response to these concerns, particulate emissions from residential cordwood stoves under actual in-home use have been measured for 5 heating seasons as part of 12 separate studies in Oregon, New York, Vermont, and the Yukon Territory. Monitoring was conducted using an automated emission sampler (AES) system. The system has been deployed in nearly 100 individual homes. Typically, emissions from several 1-week-long integrated sampling periods over the course of the heating season were measured with the AES system at each home. Particulate emission rates in grams of particles per hour of stove operation, grams of particles per kilogram of dry wood burned, and grams of particles per million Joules were calculated. Ancillary data provided by the studies included wood burn rates, homeowner wood loading patterns, wood moisture content and species, hours of operation of auxiliary heating appliances in the study homes, room ambient, flue gas, catalyst, and pre-catalyst temperatures, and hours of catalyst operation. Conventional stoves, high-technology non-catalytic stoves, catalytic stoves, and stoves equipped with retrofit catalytic devices have been studied. In addition to the 12 cordwood stove studies, the AES system has been used in 2 pellet stove studies and 1 fireplace study

  1. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2016-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 1er novembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel La permanence suivante aura lieu le mardi 29 novembre 2016. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php  

  2. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 28 novembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  3. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 30 mai de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  4. EPA Region 1 Environmentally Sensitive Areas

    Data.gov (United States)

    U.S. Environmental Protection Agency — This coverage represents polygon equivalents of environmentally sensitive areas (ESA) in EPA Region I. ESAs were developed as part of an EPA headquarters initiative...

  5. U.S. EPA Metadata Editor (EME)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA Metadata Editor (EME) allows users to create geospatial metadata that meets EPA's requirements. The tool has been developed as a desktop application that...

  6. EPA Facility Registry System (FRS): NCES

    Science.gov (United States)

    This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link to the National Center for Education Statistics (NCES). The primary federal database for collecting and analyzing data related to education in the United States and other Nations, NCES is located in the U.S. Department of Education, within the Institute of Education Sciences. FRS identifies and geospatially locates facilities, sites or places subject to environmental regulations or of environmental interest. Using vigorous verification and data management procedures, FRS integrates facility data from EPA00e2??s national program systems, other federal agencies, and State and tribal master facility records and provides EPA with a centrally managed, single source of comprehensive and authoritative information on facilities. This data set contains the subset of FRS integrated facilities that link to NCES school facilities once the NCES data has been integrated into the FRS database. Additional information on FRS is available at the EPA website http://www.epa.gov/enviro/html/fii/index.html.

  7. 2011 EPA Pesticide General Permit (PGP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The 2011 EPA Pesticide General Permit (PGP) covers discharges of biological pesticides, and chemical pesticides that leave a residue, in areas where EPA is the NPDES...

  8. Geothermal heat pumps as one of possibilities of an alternative energy used for objects heating objects in Czech Republic

    Directory of Open Access Journals (Sweden)

    Jiří Ryška

    2007-06-01

    Full Text Available The use of geothermal energy for more localised energy requirements is becoming more apparent with the use of geothermal heat pumps. The use of heat from the upper portion of the earth's crust can be useful and efficient method of energy saving. At around 50 m below the earth's surface the ambient temperature fluctuates between around 8-12 oC. This heat can be used by being transferred to the surface via a loop system using a high-efficiency refrigerant type of material.These systems are also typically more efficient than gas or oil-fired heating systems. They are more energy efficient than air-source heat pumps because they draw heat from, or release heat to, the earth, which has moderate temperatures all the year, rather than to the air. Geothermal heat pumps use the relatively constant temperature of the ground or water several meters below the earth's surface as source of heating and cooling. Geothermal heat pumps are appropriate for retrofit or new homes, where both heating and cooling are desired. In addition to heating and cooling, geothermal heat pumps can provide domestic hot water. They can be used for virtually any home size or lot in any region of the Czech Republic.

  9. Combination of a gas heat pump with geothermal energy and solar heat utilisation; Kombination einer Gaswaermepumpe mit Geothermie und Solarwaermenutzung

    Energy Technology Data Exchange (ETDEWEB)

    Peter, Andreas [Robur GmbH, Friedrichshafen (Germany)

    2009-01-15

    A home for handicapped persons in Berlin was modernised. This included the installation of a gas-fuelled absorption heat pump combined with geothermal heat supply and solar heating. CO2 emissions and primary energy consumption were reduced considerably by this concept. (orig.)

  10. Survey of residential heat pump owner experience in Canada

    Energy Technology Data Exchange (ETDEWEB)

    Unsoy, J

    1985-11-11

    Heat pump owners in 7 Canadian cities were surveyed to establish installation costs, repair costs and frequencies, and customer satisfaction with heat pump systems as a function of region, installing contractor, manufacturer, model, year of installation and system type. The following summarizes the major findings of the study. Most Canadian heat pumps are retrofit installations in existing homes. The majority of these heat pumps have either supplemented or replaced an oil furnace. The average age of heat pumps is 2.5 years. The median size of heat pumps installed is 2.5 tons. The three most popular brands by order of prevalence are York, Carrier and General Electric. Only about one-fifth of heat pump owners have purchased service contracts. Two-thirds of the heat pumps have never needed repairs. Eighty-three percent of heat pump owners have never incurred any repair costs; and of those that have, about half spent $100 or less. The most frequent repair problems are refrigerant leaks followed by relays and controls. Corrective actions average about 0.3 per unit year. The owners' evaluation of comfort from their heat pump is generally favourable. About 12% of the owners find the outdoor unit noisy and 10% feel maintenance costs are at a disadvantage. Overall, only 7% of heat pump owners indicated that they would not install a heat pump in their next house. Most heat pump owners are satisfied with their heat pump brand and installer. Owners with systems installed in newer homes are more satisfied with their heat pumps than those who have installed heat pumps in older homes. 3 figs., 93 tabs.

  11. 24 CFR 3285.905 - Heating oil systems.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Heating oil systems. 3285.905... Installation Instructions § 3285.905 Heating oil systems. It is recommended that the installation instructions include the following information related to heating oil systems, when applicable: (a) Homes equipped with...

  12. Super Energy Efficiency Design (S.E.E.D.) Home Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    German, A.; Dakin, B.; Backman, C.; Weitzel, E.; Springer, D.

    2012-12-01

    This report describes the results of evaluation by the Alliance for Residential Building Innovation (ARBI) Building America team of the 'Super Energy Efficient Design' (S.E.E.D) home, a 1,935 sq. ft., single-story spec home located in Tucson, AZ. This prototype design was developed with the goal of providing an exceptionally energy efficient yet affordable home and includes numerous aggressive energy features intended to significantly reduce heating and cooling loads such as structural insulated panel (SIP) walls and roof, high performance windows, an ERV, an air-to-water heat pump with mixed-mode radiant and forced air delivery, solar water heating, and rooftop PV. Source energy savings are estimated at 45% over the Building America B10 Benchmark. System commissioning, short term testing, long term monitoring and detailed analysis of results was conducted to identify the performance attributes and cost effectiveness of the whole house measure package.

  13. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 31 octobre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel La permanence suivante aura lieu le mardi 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  14. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 29 août de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php  

  15. Retrofitting Combined Space and Water Heating Systems: Laboratory Tests

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B.; Bohac, D.; Huelman, P.; Olson, R.; Hewitt, M.

    2012-10-01

    Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

  16. Retrofitting Combined Space and Water Heating Systems. Laboratory Tests

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B. [NorthernStar Building America Partnership, St. Paul, MN (United States); Bohac, D. [NorthernStar Building America Partnership, St. Paul, MN (United States); Huelman, P. [NorthernStar Building America Partnership, St. Paul, MN (United States); Olsen, R. [NorthernStar Building America Partnership, St. Paul, MN (United States); Hewett, M. [NorthernStar Building America Partnership, St. Paul, MN (United States)

    2012-10-01

    Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

  17. Purchasing Supplies, Equipment and Services Under EPA Grants

    Science.gov (United States)

    EPA developed this guidance to help ensure you meet EPA requirements when making such necessary purchases. With very few exceptions, you must follow a competitive process when you use EPA grant funds to acquire equipment and professional services.

  18. EPA Environmental Chemistry Laboratory

    Science.gov (United States)

    1993-01-01

    The Environmental Protection Agency's (EPA) Chemistry Laboratory (ECL) is a national program laboratory specializing in residue chemistry analysis under the jurisdiction of the EPA's Office of Pesticide Programs in Washington, D.C. At Stennis Space Center, the laboratory's work supports many federal anti-pollution laws. The laboratory analyzes environmental and human samples to determine the presence and amount of agricultural chemicals and related substances. Pictured, ECL chemists analyze environmental and human samples for the presence of pesticides and other pollutants.

  19. Notification: EPA's Preparedness and Response Efforts to the 2017 Hurricanes in EPA Regions 2, 4 and 6

    Science.gov (United States)

    Project #OPE-FY18-0005, December 13, 2017. The EPA OIG plans to begin preliminary research on the EPA’s preparedness and response efforts to the 2017 hurricanes that impacted EPA Regions 2, 4 and 6.

  20. DOE Zero Energy Ready Home Case Study: Greenhill Contracting, Inc., Hickory Ridge

    Energy Technology Data Exchange (ETDEWEB)

    Pacific Northwest National Laboratory

    2017-09-01

    Greenhill Contracting built this 3,912-ft2 house in Gardiner, New York, to the high-performance criteria of the DOE Zero Energy Ready Home (ZERH) program. A highly efficient air-source heat pump heats and cools the home’s interior, while the roof-mounted photovoltaic system offsets electricity usage to cut energy bills to nearly zero. Many months the home owners see a credit on their utility bill.

  1. EPA Regulation of Bed Bug Pesticides

    Science.gov (United States)

    All pesticides must be registered by EPA before being sold and used in the U.S., other than those that rely on a limited set of active ingredients (so-called minimum risk pesticides). EPA reviews for safety and effectiveness.

  2. Brookfield Homes Passive House Performance Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Herk, A. [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, A. [IBACOS, Inc., Pittsburgh, PA (United States); Beach, R. [IBACOS, Inc., Pittsburgh, PA (United States)

    2016-02-01

    In 2012-2013, IBACOS worked with a builder, Brookfield Homes in Denver, Colorado, to design and construct a Passive House certified model home. IBACOS used several modeling programs and calculation methods to complete the final design package along with Brookfield's architect KGA Studio. This design package included upgrades to the thermal enclosure, basement insulation, windows, and heating, ventilation, and air conditioning. Short-term performance testing in the Passive House was done during construction and after construction.

  3. Energy Savers--Tips on Saving Energy and Money at Home (Fifth Printing)

    International Nuclear Information System (INIS)

    DOE Office of Building Technology, State and Community Programs

    2001-01-01

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances

  4. Energy Savers---Tips on Saving Energy and Money at Home (Fifth Printing)

    Energy Technology Data Exchange (ETDEWEB)

    DOE Office of Building Technology, State and Community Programs

    2001-08-13

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  5. EPA Office Points, Tutuila AS, 2009, US EPA Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA office location in Tutila Island in American Samoa. American Samoa is an unincorporated and unorganized territory of the United States, and administered by...

  6. Building America Case Study: Whole-House Solutions for Existing Homes: Greenbelt Homes, Inc. Pilot Retrofit Program; Whole-House Solutions for Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-06-01

    In the fall of 2010, a multiyear pilot energy efficiency retrofit project was undertaken by Greenbelt Homes, Inc, (GHI) a 1,566 home cooperative of circa 1930 and 1940 homes in Greenbelt, Maryland. GHI established this pilot project to serve as a basis for decision making for the rollout of a decade-long community-wide upgrade program that will incorporate energy efficiency improvements to the building envelope and mechanical equipment. With the community upgrade fully funded by the cooperative through their membership without outside subsidies, this project presents a unique opportunity to evaluate and prioritize the wide-range of benefits of high-performance retrofits based on member experience with and acceptance of the retrofit measures implemented during the pilot project. Addressing the complex interactions between benefits, trade-offs, construction methods, project management implications, realistic upfront costs, financing, and other considerations, serves as a case study for energy retrofit projects to include high-performance technologies based on the long-term value to the homeowner. The pilot project focused on identifying the added costs and energy savings benefits of improvements. Phase 1: baseline evaluation for a representative set of 28 homes sited in seven buildings; Phase 2: installation of the building envelope improvements and continued monitoring of the energy consumption for the heating season and energy simulations supporting recommendations for HVAC and water heating upgrades to be implemented in Phase 3.

  7. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 26 septembre de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/ Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  8. Evaluating the Effectiveness of a Commercial Portable Air Purifier in Homes with Wood Burning Stoves: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Julie F. Hart

    2011-01-01

    Full Text Available Wood burning for residential heating is prevalent in the Rocky Mountain regions of the United States. Studies have shown that wood stoves can be a significant source of PM2.5 within homes. In this study, the effectiveness of an electrostatic filter portable air purifier was evaluated (1 in a home where a wood stove was the sole heat source and (2 in a home where a wood stove was used as a supplemental heat source. Particle count concentrations in six particle sizes and particle mass concentrations in two particle sizes were measured for ten 12-hour purifier on and ten purifier off trials in each home. Particle count concentrations were reduced by 61–85 percent. Similar reductions were observed in particle mass concentrations. These findings, although limited to one season, suggest that a portable air purifier may effectively reduce indoor particulate matter concentrations associated with wood combustion during home heating.

  9. EPA perspective on radionuclide aerosol sampling

    Energy Technology Data Exchange (ETDEWEB)

    Karhnak, J.M. [Environmental Protection Agency, Washington, DC (United States)

    1995-02-01

    The Environmental Protection Agency (EPA) is concerned with radionuclide aerosol sampling primarily at Department of Energy (DOE) facilities in order to insure compliance with national air emission standards, known as NESHAPs. Sampling procedures are specified in {open_quotes}National Emission Standards for Emissions of Radionuclides other than Radon from Department of Energy Sites{close_quotes} (Subpart H). Subpart H also allows alternate procedures to be used if they meet certain requirements. This paper discusses some of the mission differences between EPA and Doe and how these differences are reflected in decisions that are made. It then describes how the EPA develops standards, considers alternate sampling procedures, and lists suggestions to speed up the review and acceptance process for alternate procedures. The paper concludes with a discussion of the process for delegation of Radionuclide NESHAPs responsibilities to the States, and responsibilities that could be retained by EPA.

  10. EPA Envirofacts API

    Data.gov (United States)

    U.S. Environmental Protection Agency — Envirofacts integrates information from a variety of EPA's environmental databases. Each of these databases contains information about facilities that are required...

  11. Thermal design of a fully equipped solar-powered desert home

    KAUST Repository

    Serag-Eldin, M.A.

    2010-03-01

    The paper presents a conceptual design and thermodynamic analysis of a solar-powered desert home. The home is airconditioned and provides all modern comforts and facilities. Electrical power, which drives the entire energy system, is generated by roof mounted photovoltaic modules. A detailed dynamic heat transfer analysis is conducted for the building envelope, coupled with a solar radiation model. A dynamic heat balance for a typical Middle-Eastern desert site, reveals that indeed such a design is feasible with present day technology; and should be even more attractive with future advances in technology.

  12. User needs and home automation infrastructures in industrialized and developing countries

    NARCIS (Netherlands)

    Brink, M.; Bronswijk, van J.E.M.H.

    2010-01-01

    Purpose Home automation systems are meant to improve the performance of a dwelling. Middleware, the ICT infrastructure of a home automation system, connects the different applications (lighting, heating, smoke sensing, etc) by providing the network and defining the technologies used for

  13. Reducing Energy Use in Existing Homes by 30%: Learning From Home Performance with ENERGY STAR

    Energy Technology Data Exchange (ETDEWEB)

    Liaukus, C. [Building America Research Alliance (BARA), Kent, WA (United States)

    2014-12-01

    The improvement of existing homes in the United States can have a much greater impact on overall residential energy use than the construction of highly efficient new homes. There are over 130 million existing housing units in the U.S., while annually new construction represents less than two percent of the total supply (U.S. Census Bureau, 2013). Therefore, the existing housing stock presents a clear opportunity and responsibility for Building America (BA) to guide the remodeling and retrofit market toward higher performance existing homes. There are active programs designed to improve the energy performance of existing homes. Home Performance with ENERGY STAR (HPwES) is a market-rate program among them. BARA's research in this project verified that the New Jersey HPwES program is achieving savings in existing homes that meet or exceed BA's goal of 30%. Among the 17 HPwES projects with utility data included in this report, 15 have actual energy savings ranging from 24% to 46%. Further, two of the homes achieved that level of energy savings without the costly replacement of heating and cooling equipment, which indicates that less costly envelope packages could be offered to consumers unable to invest in more costly mechanical packages, potentially creating broader market impact.

  14. DOE Zero Energy Ready Home Case Study: The Imery Group — Proud Green Home, Serenbe, GA

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-09-01

    The first certified Zero Energy Ready Home in Georgia was honored in the Custom Builder category of the 2014 Housing Innovation Awards. The 2,811-ft2, two-story custom home has 2x6 advanced framed walls filled with R-20 of open-cell spray foam, plus an R-6.6 insulated coated OSB sheathing. Also included is electronic monitoring equipment that tracks the PV, solar thermal water heater, ERV, mini-split heat pump with three indoor heads, solar water heater, and LED and CFL lighting.

  15. EPA Recovery Mapper

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA Recovery Mapper is an Internet interactive mapping application that allows users to discover information about every American Recovery and Reinvestment Act...

  16. EPA requirements for the uranium fuel cycle

    International Nuclear Information System (INIS)

    Dunster, H.J.

    1975-01-01

    The draft Environmental Statement issued by the Environmental Protection Agency (EPA) in the United States in preparation for Proposed Rulemaking Action concerning 'Environmental radiation protection requirements for normal operations of activities in the uranium fuel cycle' is summarized and discussed. The standards proposed by the EPA limit the annual dose equivalents to any member of the public, and also the releases of radionuclides to the 'general environment' for each gigawatt year of electrical energy produced. These standards were based on cost effectiveness arguements and levels and correspond to the ICRP recommendation to keep all exposures as low as reasonably achievable, economic and social factors being taken into account. They should be clearly distinguished from dose limits, although the EPA does not make this at all clear. The EPA seems to have shown an unexpected lack of understanding of the recommendations of ICRP Publication 9 (1965) and an apparent unawareness of ICRP Publication 22 (1973), and has therefore wrongly presented the new standards as a significant change in policy. The EPA has reviewed the information on the likely level of dose equivalents to members of the public and the likely cost reductions, thereby quantifying existing principles as applied to the fuel cycle as a whole. The EPA has stated that its proposals could be achieved as a cost in the region of Pound100,000 per death (or major genetic defect). It is pointed out that the EPA's use of the term 'waste' to exclude liquid and gaseous effluents may cause confusion. (U.K.)

  17. Hispanos en la EPA: Grace Robiou

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  18. Hispanos en la EPA: Fabiola Estrada

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  19. Hispanos en la EPA: Matthew Tejada

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  20. Hispanos en la EPA: Joel Corona

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  1. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 25 avril de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 30 mai, 29 août, 26 septembre, 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  2. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 28 février de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 28 mars, 25 avril, 30 mai, 29 août, 26 septembre, 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  3. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 28 mars de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 25 avril, 30 mai, 29 août, 26 septembre, 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  4. GAC-EPA

    CERN Multimedia

    GAC-EPA

    2017-01-01

    Le GAC organise des permanences avec entretiens individuels qui se tiennent le dernier mardi de chaque mois, sauf en juin, juillet et décembre. La prochaine permanence se tiendra le : Mardi 30 mai de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 29 août, 26 septembre, 31 octobre et 28 novembre 2017. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires. Informations : http://gac-epa.org/. Formulaire de contact : http://gac-epa.org/Organization/ContactForm/ContactForm-fr.php

  5. Solar Energy for Space Heating & Hot Water.

    Science.gov (United States)

    Energy Research and Development Administration, Washington, DC. Div. of Solar Energy.

    This pamphlet reviews the direct transfer of solar energy into heat, particularly for the purpose of providing space and hot water heating needs. Owners of buildings and homes are provided with a basic understanding of solar heating and hot water systems: what they are, how they perform, the energy savings possible, and the cost factors involved.…

  6. EPA Linked Open Data: Substance Registry Service

    Data.gov (United States)

    U.S. Environmental Protection Agency — Substance Registry Services (SRS) is the Environmental Protection Agency's (EPA) central system for information about substances that are tracked or regulated by EPA...

  7. Low-level and narm radioactive wastes. Model documentation: accounting model for PRESTO-EPA-POP, PRESTO-EPA-DEEP, and PRESTO-EPA-BRC. Methodology and users manual. Final report

    International Nuclear Information System (INIS)

    Rogers, V.; Hung, C.

    1987-12-01

    The accounting model was used as a utility model for assessing the cumulative health effects to the general population residing in the downstream regional water basin as a result of the disposal of LLW when a unit response analysis method is used. The utility model is specifically designed to assess the cumulative population health effects in conjunction with the PRESTO-EPA-POP, PRESTO-EPA-BRC, or PRESTO-EPA-DEEP model simply for the purpose of reducing the cost of analysis. Therefore, the assessment of the cumulative population health effects may also be conducted with one of the above appropriate models without the aid of this accounting model

  8. EPA User Personas

    Science.gov (United States)

    Learn how EPA's three web user personas (Information Consumer, Information Intermediary, and Information Interpreter) can help you identify appropriate top audiences and top tasks for a topic or web area.

  9. EPA Nanorelease Dataset

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPA Nanorelease Dataset. This dataset is associated with the following publication: Wohlleben, W., C. Kingston, J. Carter, E. Sahle-Demessie, S. Vazquez-Campos, B....

  10. Perfiles de hispanos en la EPA

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente de todos.

  11. Analyzing Design Heating Loads in Superinsulated Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Arena, Lois [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2015-06-16

    The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings (CARB) worked with the EcoVillage cohousing community in Ithaca, New York, on the Third Residential EcoVillage Experience neighborhood. This communityscale project consists of 40 housing units—15 apartments and 25 single-family residences. Units range in size from 450 ft2 to 1,664 ft2 and cost from $80,000 for a studio apartment to $235,000 for a three- or four-bedroom single-family home. For the research component of this project, CARB analyzed current heating system sizing methods for superinsulated homes in cold climates to determine if changes in building load calculation methodology should be recommended. Actual heating energy use was monitored and compared to results from the Air Conditioning Contractors of America’s Manual J8 (MJ8) and the Passive House Planning Package software. Results from that research indicate that MJ8 significantly oversizes heating systems for superinsulated homes and that thermal inertia and internal gains should be considered for more accurate load calculations.

  12. Home in the heat: Dramatic seasonal variation in home range of desert golden eagles informs management for renewable energy development

    Science.gov (United States)

    Braham, Melissa A.; Miller, Tricia A.; Duerr, Adam E.; Lanzone, Michael J.; Fesnock, Amy; LaPre, Larry; Driscoll, Daniel; Katzner, Todd E.

    2015-01-01

    Renewable energy is expanding quickly with sometimes dramatic impacts to species and ecosystems. To understand the degree to which sensitive species may be impacted by renewable energy projects, it is informative to know how much space individuals use and how that space may overlap with planned development. We used global positioning system–global system for mobile communications (GPS-GSM) telemetry to measure year-round movements of golden eagles (Aquila chrysaetos) from the Mojave Desert of California, USA. We estimated monthly space use with adaptive local convex hulls to identify the temporal and spatial scales at which eagles may encounter renewable energy projects in the Desert Renewable Energy Conservation Plan area. Mean size of home ranges was lowest and least variable from November through January and greatest in February–March and May–August. These monthly home range patterns coincided with seasonal variation in breeding ecology, habitat associations, and temperature. The expanded home ranges in hot summer months included movements to cooler, prey-dense, mountainous areas characterized by forest, grasslands, and scrublands. Breeding-season home ranges (October–May) included more lowland semi-desert and rock vegetation. Overlap of eagle home ranges and focus areas for renewable energy development was greatest when eagle home ranges were smallest, during the breeding season. Golden eagles in the Mojave Desert used more space and a wider range of habitat types than expected and renewable energy projects could affect a larger section of the regional population than was previously thought.

  13. Building America Best Practices Series, Volume 6: High-Performance Home Technologies: Solar Thermal & Photovoltaic Systems

    Energy Technology Data Exchange (ETDEWEB)

    Baechler, Michael C.; Gilbride, Theresa L.; Ruiz, Kathleen A.; Steward, Heidi E.; Love, Pat M.

    2007-06-04

    This guide is was written by PNNL for the US Department of Energy's Building America program to provide information for residential production builders interested in building near zero energy homes. The guide provides indepth descriptions of various roof-top photovoltaic power generating systems for homes. The guide also provides extensive information on various designs of solar thermal water heating systems for homes. The guide also provides construction company owners and managers with an understanding of how solar technologies can be added to their homes in a way that is cost effective, practical, and marketable. Twelve case studies provide examples of production builders across the United States who are building energy-efficient homes with photovoltaic or solar water heating systems.

  14. EPA's role in uranium mining and milling

    International Nuclear Information System (INIS)

    Smith, P.B.

    1980-01-01

    EPA's role and actions in regulating uranium mining and milling are reviewed and updated. Special emphasis is given to EPA's current activities under the Uranium Mill Tailings Radiation Control Act of 1978

  15. Assessment of relative POHC destruction at EPA's incineration research facility

    International Nuclear Information System (INIS)

    Carroll, G.J.; Lee, J.W.

    1992-01-01

    As part of their permitting process, hazardous waste incinerators must undergo demonstration tests, or trial burns, during which their ability to meet EPA performance standards is evaluated. Among the performance standards is a minimum destruction and removal efficiency (DRE) for principal organic hazardous constituents (POHCs) in the incinerator waste feed. In accordance with the regulations promulgated under the Resource Conservation and Recovery Act (RCRA), selection POHCs for incinerator trial burns is to be based on the degree of difficulty of incineration of the organic constituents in the waste and on their concentration or mass in the waste feed. In order to predict the relative difficulty of incineration specific compounds, several incinerability ranking approaches have been proposed, including a system based on POHC heats of combustion and a system based on thermal stability under pyrolytic condition. The latter ranking system was developed by the University of Dayton Research Institute (UDRI) under contract to the US EPA Risk Reduction Engineering Laboratory (RREL). The system is supported largely by non-flame, laboratory-scale data and is based on kinetic calculations indicating that contributor to emissions of undestroyed organic compounds. The subject tests were conducted to develop data on POHC behavior in a larger-scale, conventional incineration environment. 5 refs., 3 tabs

  16. DOE Zero Energy Ready Home Case Study: Alliance Green Builders, Casa Aguila

    Energy Technology Data Exchange (ETDEWEB)

    Pacific Northwest National Laboratory

    2017-09-01

    Alliance Green Builders built this 3,129-ft2 home in the hills above Ramona, California, to the high-performance criteria of the DOE Zero Energy Ready Home (ZERH) program. The home should perform far better than net zero thanks to a super-efficient building shell, a wind turbine, three suntracking solar photovoltaic arrays, and solar thermal water heating.

  17. The changing character of household waste in the Czech Republic between 1999 and 2009 as a function of home heating methods.

    Science.gov (United States)

    Doležalová, Markéta; Benešová, Libuše; Závodská, Anita

    2013-09-01

    The authors of this paper report on the changing character of household waste, in the Czech Republic between 1999 and 2009 in households differentiated by their heating methods. The data presented are the result of two projects, financed by the Czech Ministry of Environment, which were undertaken during this time period with the aim of focusing on the waste characterisation and complete analysis of the physicochemical properties of the household waste. In the Czech Republic, the composition of household waste varies significantly between different types of households based on the methods of home heating employed. For the purposes of these studies, the types of homes were divided into three categories - urban, mixed and rural. Some of the biggest differences were found in the quantities of certain subsample categories, especially fine residue (matter smaller than 20 mm), between urban households with central heating and rural households that primarily employ solid fuel such coal or wood. The use of these solid fuels increases the fraction of the finer categories because of the higher presence of ash. Heating values of the residual household waste from the three categories varied very significantly, ranging from 6.8 MJ/kg to 14.2 MJ/kg in 1999 and from 6.8 MJ/kg to 10.5 MJ/kg in 2009 depending on the type of household and season. The same factors affect moisture of residual household waste which varied from 23.2% to 33.3%. The chemical parameters also varied significantly, especially in the quantities of Tl, As, Cr, Zn, Fe and Mn, which were higher in rural households. Because knowledge about the properties of household waste, as well as its physicochemical characteristics, is very important not only for future waste management, but also for the prediction of the behaviour and influence of the waste on the environment as the country continues to streamline its legislation to the European Union's solid waste mandates, the results of these studies were employed by the

  18. Indirect Solar Water Heating in Single-Family, Zero Energy Ready Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, Robb [Steven Winters Associates, Inc., Norwalk, CT (United States)

    2016-02-01

    In western Massachusetts, an affordable housing developer built a community of 20 homes with the goal of approaching zero energy consumption. In addition to excellent thermal envelopes and photovoltaic systems, the developer installed a solar domestic hot water (SDHW) system on each home. The Consortium for Advanced Residential Buildings (CARB), a U.S. Department of Energy Building America research team, commissioned some of the systems, and CARB was able to monitor detailed performance of one system for 28 months.

  19. Pollution prevention initiatives at US EPA: 'Green Lights'

    International Nuclear Information System (INIS)

    Lawson, J.; Kwartin, R.

    1991-01-01

    US EPA is initiating a pollution prevention approach to supplement its historic command-control, regulatory approach to environmental protection. EPA believes polllution prevention, where applicable and possible, represents a quicker, less expensive and even profitable strategy for environmental protection. Most clearly, energy-efficiency provides an opportunity to prevent significant amounts of pollution related to the inefficeint generation and use of electricity. EPA's first energy productivity and pollution prevention program is Green Lights. Beyond its own merits, Green Lights will also provide important experience to EPA as it develops its Green Machines program to accelerate the market for efficient appliances and equipment

  20. Privacy Act System of Records: EPA Telecommunications Detail Records, EPA-32

    Science.gov (United States)

    Learn more about the EPA Telecommunications Detail Records System, including who is covered in the system, the purpose of data collection, routine uses for the system's records, and other security procedures.

  1. 40 CFR 73.52 - EPA recordation.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false EPA recordation. 73.52 Section 73.52... ALLOWANCE SYSTEM Allowance Transfers § 73.52 EPA recordation. (a) General recordation. Except as provided in...) following receipt of an allowance transfer request pursuant to § 73.50, by moving each allowance from the...

  2. Eco-efficiency of holiday homes; Vapaa-ajan asumisen ekotehokkuus

    Energy Technology Data Exchange (ETDEWEB)

    Rytkoenen, A.; Kirkkari, A.-M. (eds.) (Work Efficiency Inst., Rajamaeki (Finland))

    2010-03-15

    The study is part of the Environmental Cluster Research Programme of the Ministry of the Environment and was done by seven research institutes. The study examined holiday homes in terms of their potential for enhancing sustainable consumption and eco-efficiency. The research focused on: constant heating and frost-proof plumbing, their acceptability, use of services and future needs, the operating requirements for home appliances, travel to cottages, and their macroeconomic effects. Next to construction and repair services summer cottage owners were interested in improvement of transport and health care services, telecommuting and the installation of constant heating systems and frost-proof plumbing. As of 2008, there were approximately 478,000 summer cottages. Each year, 4,000 new cottages are built, while 3,000 old cottages are extended, repaired and partly rebuilt so that they are almost like new buildings. Approximately 76 percent of all cottages are connected to the power grid. Just under one-third of all cottages are fitted for year-round use. Raising the level of cottage amenities increases their utilisation rate and energy consumption. Traditional, primarily summer-use cottages with wood-burning heat, bucket-drawn water and dry toilets are eco-efficient. Heating and travelling to cottages are the largest consumers of energy in cottage living. Travelling to cottages consumes approximately 1,070 GWh per year. The more that various electric appliances are used in the cottages and the more comfortable they become, the more often they are visited also during winter time and the higher are the energy and emission bills. Traffic to the holiday homes increases also because of growing mean distances between peopleAEs main residences and cottages and because of increased visits to friendsAE and relativesAE cottages and to rented holiday housing in Lapland and elsewhere. In 2005 total cottage electricity consumption was approximately 900 GWh/year. The average

  3. Factors of subjective heat stress of urban citizens in contexts of everyday life

    Science.gov (United States)

    Kunz-Plapp, Tina; Hackenbruch, Julia; Schipper, Janus Willem

    2016-04-01

    Heat waves and the consequent heat stress of urban populations have a growing relevance in urban risk management and strategies of urban adaptation to climate change. In this context, social science studies on subjective experiencing of heat as stress by urban citizens are a new emerging field. To contribute to the understanding of self-reported subjective heat stress and its major determinants in a daily life perspective, we conducted a questionnaire survey with 323 respondents in Karlsruhe, Germany, after heat waves in July and August 2013. Statistical data analysis showed that subjective heat stress is an issue permeating everyday activities. Subjective heat stress at home was lower than at work and in general. Subjective heat stress in general, at home, and at work was determined by the health impairments experienced during the heat and the feeling of being helplessly exposed to the heat. For subjective heat stress at home, characteristics of the residential building and the built environment additionally played a role. Although the rate of implemented coping measures was rather high, coping measures showed no uniform effect for the subjective heat stress. We conclude that in terms of urban adaptation strategies, further research is needed to understand how various processes of daily social (work) life enable or limit individual coping and that communication strategies are important for building capacities to better cope with future heat waves.

  4. Electric radiant heating : a hot profitable idea

    Energy Technology Data Exchange (ETDEWEB)

    Lemieux, G. [Britech Corp., Toronto, ON (Canada)

    2006-09-15

    Due to the high cost of heating oil, natural gas and propane, floor mounted radiant heating systems are now proving to be a cost effective method of heating homes. The systems provide evenly distributed heat across the entire floor area. Unlike hydronic floor systems, radiant floor systems require no maintenance, and are easy to control because no mechanical rooms or boilers are required. The system is comprised of a series of resistant heating cables, a thermostat, and a solid state relay. The cables are installed in a poured concrete pad. Separate temperature control devices are used to heat individual areas of floorspace. Building automation systems can also control the heating system by using simple ambient air- and floor-mounted sensors in conjunction with relays to energize the heating cables. The cost of thermostats and heating cables to heat a standard 2000 square foot home are estimated at $9000.00, with an additional 64 hours of installation costs. It was noted that the systems may prove to be less costly in the long-term than hydronic systems, which require additional boilers, pumps and water treatments. Electric radiant heating can be an even more cost-effective application when used with thermal storage heating applications that use lower-cost off-peak electricity to generate and store heat in concrete floor slabs or ceramic bricks contained in insulated cabinets. It was concluded that radiant heating systems are a viable and cost-effective alternative to expensive hydronic systems, which are costly to install and maintain. 4 figs.

  5. EPA Region 1 Sole Source Aquifers

    Science.gov (United States)

    This coverage contains boundaries of EPA-approved sole source aquifers. Sole source aquifers are defined as an aquifer designated as the sole or principal source of drinking water for a given aquifer service area; that is, an aquifer which is needed to supply 50% or more of the drinking water for the area and for which there are no reasonable alternative sources should the aquifer become contaminated.The aquifers were defined by a EPA hydrogeologist. Aquifer boundaries were then drafted by EPA onto 1:24000 USGS quadrangles. For the coastal sole source aquifers the shoreline as it appeared on the quadrangle was used as a boundary. Delineated boundaries were then digitized into ARC/INFO.

  6. Users of electric heating rewarded

    Energy Technology Data Exchange (ETDEWEB)

    Haapakoski, M. [ed.

    1998-07-01

    When the building industry plunged into the deep recession of the early 1990s this did not paralyse research and development work on electric heating. In fact, IVO and power companies launched the `Electrically Heated Homes in the New Millennium` project in 1992. Its purpose was to verify the efficiency, energy economy and residential comfort of model systems using state-of-the-art electric heating technology. The research project launched six years ago is now nearing completion. Its findings indicate that electricity brings ever more unparalleled benefits when it is used for heating. These benefits involve residential comfort, ease of use and economy

  7. Home is where the hearth is: grant recipients' views of England's home energy efficiency scheme (Warm Front).

    Science.gov (United States)

    Gilbertson, Jan; Stevens, Maryjane; Stiell, Bernadette; Thorogood, Nicki

    2006-08-01

    This paper reports the results of research carried out as part of the national health impact evaluation of the Warm Front Scheme, a government initiative aimed at alleviating fuel poverty in England. Semi-structured interviews were carried out in a purposive sample of 49 households which received home energy improvements under the Scheme from five urban areas (Birmingham, Liverpool, Manchester, Newcastle, Southampton). Each household had received installation, replacement or refurbishment of the heating system and, in some cases, also insulation of the cavity wall or loft or both, and draught-proofing measures. Most householders reported improved and more controllable warmth and hot water. Many also reported perceptions of improved physical health and comfort, especially of mental health and emotional well-being and, in several cases, the easing of symptoms of chronic illness. There were reports of improved family relations, an expansion of the domestic space used during cold months, greater use of kitchens and improved nutrition, increased privacy, improved social interaction, and an increase in comfort and atmosphere within the home. Greater warmth and comfort also enhanced emotional security, and recipients were more content and at ease in their homes. However there was little evidence of substantially lower heating bills. These results provide evidence that Warm Front home energy improvements are accompanied by appreciable benefits in terms of use of living space, comfort and quality of life, physical and mental well-being, although there is only limited evidence of change in health behaviour.

  8. Meet EPA Engineer Shawn Ryan, Ph.D.

    Science.gov (United States)

    Shawn Ryan, Ph.D. is a chemical engineer at EPA's National Homeland Security Research Center. He has worked at EPA for 12 years, nine of which have been devoted to leading research to support decontamination and consequence management.

  9. Meet EPA Ecologist Paul Mayer, Ph.D.

    Science.gov (United States)

    EPA ecologist Paul Mayer, Ph.D. works in EPA's Groundwater and Ecosystem Restoration division where he studies riparian zones (the area along rivers and streams where the habitats are influenced by both the land and water) and stream restoration

  10. US EPA Regional Masks Web Service, US, 2015, US EPA, SEGS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web service contains the following map layers: masks and labels for EPA regions 1 through 10. Mask layers are drawn at all scales. Label layers draw at scales...

  11. Proposed Changes to EPA's Transuranic Waste Characterization Approval Process

    International Nuclear Information System (INIS)

    Joglekar, R.D.; Feltcorn, E.M.; Ortiz, A.M.

    2003-01-01

    This paper describes the changes to the waste characterization (WC) approval process proposed in August 2002 by the U.S. Environmental Protection Agency (EPA or the Agency or we). EPA regulates the disposal of transuranic (TRU) waste at the Waste Isolation Pilot Plant (WIPP) repository in Carlsbad, New Mexico. EPA regulations require that waste generator/storage sites seek EPA approval of WC processes used to characterize TRU waste destined for disposal at WIPP. The regulations also require that EPA verify, through site inspections, characterization of each waste stream or group of waste streams proposed for disposal at the WIPP. As part of verification, the Agency inspects equipment, procedures, and interviews personnel to determine if the processes used by a site can adequately characterize the waste in order to meet the waste acceptance criteria for WIPP. The paper discusses EPA's mandate, current regulations, inspection experience, and proposed changes. We expect that th e proposed changes will provide equivalent or improved oversight. Also, they would give EPA greater flexibility in scheduling and conducting inspections, and should clarify the regulatory process of inspections for both Department of Energy (DOE) and the public

  12. Measured Whole-House Performance of TaC Studios Test Home

    Energy Technology Data Exchange (ETDEWEB)

    Butler, T. [Southface Energy Institute, Upper Marlboro, MD (United States); Curtis, O. [Southface Energy Institute, Upper Marlboro, MD (United States); Stephenson, R. [Southface Energy Institute, Upper Marlboro, MD (United States)

    2013-12-01

    As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta-based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA, in the mixed humid climate. This home serves as a residence and home office for the firm's owners, as well as a demonstration of their design approach to potential and current clients. Southface believes the home demonstrates current best practices for the mixed-humid climate, including a building envelope featuring advanced air sealing details and low density spray foam insulation, glazing that exceeds ENERGY STAR requirements, and a high performance heating and cooling system. Construction quality and execution was a high priority for TaC Studios and was ensured by a third party review process. Post-construction testing showed that the project met stated goals for envelope performance, an air infiltration rate of 2.15 ACH50. The homeowners wished to further validate whole house energy savings through the project's involvement with Building America and this long-term monitoring effort. As a Building America test home, this home was evaluated to detail whole house energy use, end use loads, and the efficiency and operation of the ground source heat pump and associated systems. Given that the home includes many non-typical end use loads including a home office, pool, landscape water feature, and other luxury features not accounted for in Building America modeling tools, these end uses were separately monitored to determine their impact on overall energy consumption.

  13. Towards the production of EPA: a developing country perspective

    CSIR Research Space (South Africa)

    Maharajh, Dheepak M

    2015-03-01

    Full Text Available are focussed towards increased production of high purity EPA. This provides a window of opportunity for a supply of competing products that are rich in algal EPA. Recently the CSIR developed a technology for the production of EPA by an indigenous algal isolate...

  14. Can we improve the identification of cold homes for targeted home energy-efficiency improvements?

    International Nuclear Information System (INIS)

    Hutchinson, Emma J.; Wilkinson, Paul; Hong, Sung H.; Oreszczyn, Tadj

    2006-01-01

    Objective: To investigate the extent to which homes with low indoor-temperatures can be identified from dwelling and household characteristics. Design: Analysis of data from a national survey of dwellings, occupied by low-income households, scheduled for home energy-efficiency improvements. Setting: Five urban areas of England: Birmingham, Liverpool, Manchester, Newcastle and Southampton. Methods: Half-hourly living-room temperatures were recorded for two to four weeks in dwellings over the winter periods November to April 2001-2002 and 2002-2003. Regression of indoor on outdoor temperatures was used to identify cold-homes in which standardized daytime living-room and/or nighttime bedroom-temperatures were o C (when the outdoor temperature was 5 o C). Tabulation and logistic regression were used to examine the extent to which these cold-homes can be identified from dwelling and household characteristics. Results: Overall, 21.0% of dwellings had standardized daytime living-room temperatures o C, and 46.4% had standardized nighttime bedroom-temperatures below the same temperature. Standardized indoor-temperatures were influenced by a wide range of household and dwelling characteristics, but most strongly by the energy efficiency (SAP) rating and by standardized heating costs. However, even using these variables, along with other dwelling and household characteristics in a multi-variable prediction model, it would be necessary to target more than half of all dwellings in our sample to ensure at least 80% sensitivity for identifying dwellings with cold living-room temperatures. An even higher proportion would have to be targeted to ensure 80% sensitivity for identifying dwellings with cold-bedroom temperatures. Conclusion: Property and household characteristics provide only limited potential for identifying dwellings where winter indoor temperatures are likely to be low, presumably because of the multiple influences on home heating, including personal choice and

  15. Use of low level of continuous heat and Ibuprofen as an adjunct to physical therapy improves pain relief, range of motion and the compliance for home exercise in patients with nonspecific neck pain: A randomized controlled trial.

    Science.gov (United States)

    Petrofsky, Jerrold S; Laymon, Michael; Alshammari, Faris; Khowailed, Iman Akef; Lee, Haneul

    2017-01-01

    It has been well documented at heat reduces pain and increases healing by increasing blood flow in tissue. The purpose of this study was to see if the use of low level continuous heat (LLCH) and Ibuprofen used as a home therapy between physical therapy sessions at a clinic resulted in better therapy outcomes in people with chronic neck pain. Ninety-two patients with chronic nonspecific neck pain were randomly divided into 4 groups; LLCH group, LLCH with Ibuprofen (IP) group, sham LLCH with sham IP group, and controls. All subjects underwent 45 minutes of conventional physical therapy twice a week for 2 weeks. the neck disability index (NDI), subjective pain, range of motion (ROM), strength of the neck, and home exercise compliance were measured. Both LLCH and IP significantly reduced pain and NDI score, and increased ROM (ppain significantly improved pain attenuation and it causes greater compliance for home.

  16. Variability in Measured Space Temperatures in 60 Homes

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, D.; Lay, K.

    2013-03-01

    This report discusses the observed variability in indoor space temperature in a set of 60 homes located in Florida, New York, Oregon, and Washington. Temperature data were collected at 15-minute intervals for an entire year, including living room, master bedroom, and outdoor air temperature (Arena, et. al). The data were examined to establish the average living room temperature for the set of homes for the heating and cooling seasons, the variability of living room temperature depending on climate, and the variability of indoor space temperature within the homes. The accuracy of software-based energy analysis depends on the accuracy of input values. Thermostat set point is one of the most influential inputs for building energy simulation. Several industry standards exist that recommend differing default thermostat settings for heating and cooling seasons. These standards were compared to the values calculated for this analysis. The data examined for this report show that there is a definite difference between the climates and that the data do not agree well with any particular standard.

  17. How low can the low heating load density district heating be? Environmental aspects on low heating load density district heating of the present generation compared to a domestic oil burner; Hur vaermegles kan den vaermeglesa fjaerrvaermen vara? Miljoeaspekter paa vaermegles fjaerrvaerme med dagens teknik jaemfoerd med villaoljepanna

    Energy Technology Data Exchange (ETDEWEB)

    Froeling, Morgan [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Chemical Environmental Science

    2005-07-01

    In Sweden we can see an increase of district heating networks in residential areas with low heat density. For the customer the economy is normally the most important argument when deciding to choose district heating. For many customers, however, arguments regarding environmental friendliness are important complimentary arguments. When district heating systems are built with decreased heat density, the environmental impacts from use of district heating will increase, depending on such as increased need of pipes and increased heat losses from the distribution system. The purpose of this study is to investigate if there is a limit, a lowest heat density when it is not any longer beneficial to build district heating when district heating replaces local oil furnace heating. Life cycle inventory data for district heating distribution systems in areas with low heat density has been compared with the use of oil furnaces. The environmental impacts are categorized into Global Warming Potential, Acidification Potential, Eutrofication Potential and Use of Finite Resources. To enhance the assessment three single point indicators have also been used: EcoIndicator99, EPS and ExternE. The economics of using district heating in areas with low heat density has not been regarded in this study. A model comparing the space heating of a single family home with an oil furnace or with district heating has been created. The home has an annual heat need of 20 MWh. The district heating distribution network is characterized by its linear heat density. The linear heat density is a rough description of a district heating network, and thus also the results from the model will be general. Still it can give us a general idea of the environmental limit for district heating in areas with low heat density. An assessment of all results indicate that with the type of technology used at present it is not environmentally beneficial to use district heating with lower linear heat density than 0,2 MWh/m. At

  18. EPA Facility Registry Service (FRS): Wastewater Treatment Plants

    Data.gov (United States)

    U.S. Environmental Protection Agency — This GIS dataset contains data on wastewater treatment plants, based on EPA's Facility Registry Service (FRS), EPA's Integrated Compliance Information System (ICIS)...

  19. EPA SCIENCE FORUM - EPA'S TOXICOGENOMICS PARTNERSHIPS ACROSS GOVERNMENT, ACADEMIA AND INDUSTRY

    Science.gov (United States)

    Over the past decade genomics, proteomics and metabonomics technologies have transformed the science of toxicology, and concurrent advances in computing and informatics have provided management and analysis solutions for this onslaught of toxicogenomic data. EPA has been actively...

  20. EPA Scientific Knowledge Management Assessment and Needs

    Science.gov (United States)

    A series of activities have been conducted by a core group of EPA scientists from across the Agency. The activities were initiated in 2012 and the focus was to increase the reuse and interoperability of science software at EPA. The need for increased reuse and interoperability ...

  1. Hispanos en la EPA: Evelyn Rivera-Ocasio

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  2. Hispanos en la EPA: Nadtya Y. Hong

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  3. Evaluation of Cellular Shades in the PNNL Lab Homes

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, Joseph M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sullivan, Greg [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Cort, Katherine A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Metzger, Cheryn E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Merzouk, Massine [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-01

    This report examines the energy performance of cellular shade window coverings in a matched pair of all-electric, factory-built “Lab Homes” located on the Pacific Northwest National Laboratory (PNNL) campus in Richland, Washington. The 1500-square-foot homes were identical in construction and baseline performance, which allowed any difference in energy and thermal performance between the baseline home and the experimental home to be attributed to the retrofit technology installed in the experimental home. To assess the performance of high efficiency window attachments in a residential retrofit application, the building shell air leakage, energy use, and interior temperatures of each home were compared during the 2015 -2016 winter heating and summer cooling seasons. Hunter Douglas Duette® Architella® Trielle™ opaque honeycomb “cellular” shades were installed over double-pane clear-glass, aluminum-frame primary windows in the experimental home and were compared to identical primary windows with no window coverings and with standard typical white vinyl horizontal blind window coverings in the baseline home.

  4. Privacy Act System of Records: EPA Personnel Emergency Contact Files, EPA-44

    Science.gov (United States)

    Learn about the EPA Personnel Emergency Contact Files System, including including who is covered in the system, the purpose of data collection, routine uses for the system's records, and other security procedure.

  5. BIODIESEL BLENDS IN SPACE HEATING EQUIPMENT

    International Nuclear Information System (INIS)

    KRISHNA, C.R.

    2001-01-01

    Biodiesel is a diesel-like fuel that is derived from processing vegetable oils from various sources, such as soy oil, rapeseed or canola oil, and also waste vegetable oils resulting from cooking use. Brookhaven National laboratory initiated an evaluation of the performance of blends of biodiesel and home heating oil in space heating applications under the sponsorship of the Department of Energy (DOE) through the National Renewable Energy Laboratory (NREL). This report is a result of this work performed in the laboratory. A number of blends of varying amounts of a biodiesel in home heating fuel were tested in both a residential heating system and a commercial size boiler. The results demonstrate that blends of biodiesel and heating oil can be used with few or no modifications to the equipment or operating practices in space heating. The results also showed that there were environmental benefits from the biodiesel addition in terms of reductions in smoke and in Nitrogen Oxides (NOx). The latter result was particularly surprising and of course welcome, in view of the previous results in diesel engines where no changes had been seen. Residential size combustion equipment is presently not subject to NOx regulation. If reductions in NOx similar to those observed here hold up in larger size (commercial and industrial) boilers, a significant increase in the use of biodiesel-like fuel blends could become possible

  6. EPA's Final Financial Assistance Conflict of Interest Policy

    Science.gov (United States)

    EPA has established the following revised interim policy governing disclosure of actual and potential conflicts of interest (COI Policy) by applicants for, and recipients of, federal financial assistance awards from EPA.

  7. Emerging large-scale solar heating applications

    International Nuclear Information System (INIS)

    Wong, W.P.; McClung, J.L.

    2009-01-01

    Currently the market for solar heating applications in Canada is dominated by outdoor swimming pool heating, make-up air pre-heating and domestic water heating in homes, commercial and institutional buildings. All of these involve relatively small systems, except for a few air pre-heating systems on very large buildings. Together these applications make up well over 90% of the solar thermal collectors installed in Canada during 2007. These three applications, along with the recent re-emergence of large-scale concentrated solar thermal for generating electricity, also dominate the world markets. This paper examines some emerging markets for large scale solar heating applications, with a focus on the Canadian climate and market. (author)

  8. Emerging large-scale solar heating applications

    Energy Technology Data Exchange (ETDEWEB)

    Wong, W.P.; McClung, J.L. [Science Applications International Corporation (SAIC Canada), Ottawa, Ontario (Canada)

    2009-07-01

    Currently the market for solar heating applications in Canada is dominated by outdoor swimming pool heating, make-up air pre-heating and domestic water heating in homes, commercial and institutional buildings. All of these involve relatively small systems, except for a few air pre-heating systems on very large buildings. Together these applications make up well over 90% of the solar thermal collectors installed in Canada during 2007. These three applications, along with the recent re-emergence of large-scale concentrated solar thermal for generating electricity, also dominate the world markets. This paper examines some emerging markets for large scale solar heating applications, with a focus on the Canadian climate and market. (author)

  9. Energy renovation practices in Danish homes. The influence of energy labels on home renovation practices

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, Toke Haunstrup; Gram-Hanssen, Kirsten [Danish Building Research Institute, Aalborg University, Dr. Neergaards Vej 15, DK-2970 Hoersholm (Denmark); Adjei, Afi [Building Research Establishment Ltd. BRE, Bucknalls Lane, Garston, WD25 9XX Watford (United Kingdom); De Best-Waldhober, Marjolein [Energy research Centre of the Netherlands ECN, Policy Studies, Amsterdam (Netherlands)

    2012-02-15

    Heating of dwellings represents a major policy challenge for the transition to a low carbon society. In Denmark, heating of dwellings represents about 25% of the total Danish final energy consumption and about 13% of the total CO2 emission. The majority of this is related to heating of older dwellings, and as the rate of replacement is low, the main potential for energy saving is to improve the energy efficiency of the existing dwelling stock through energy renovation. This paper provides an analysis of Danish experiences with energy labels (also known as the Energy Performance Certificate, EPC), which indicate the energy efficiency of buildings and include recommendations for improvements. The aim of the EPC is to motivate homeowners to do energy improvements. In Denmark, energy audit schemes date back to the early 1980s and energy rating of houses (energy labelling) was introduced in 1997. The long history of energy audit schemes and energy labelling makes Denmark an interesting case for the study of the experiences with and impact of this kind of policy measure. With the EU Energy Performance of Buildings Directive (EPBD) from 2002, an energy labelling scheme similar to the Danish scheme introduced in 1997 is now in use in all EU member states. The focus of this paper is on the homeowners' experience and use of the EPC and the key research questions are: How do the homeowners understand and use the EPC? Does the EPC have an influence on home energy renovation practices? The analysis is based on results from a survey of Danish homeowners who have purchased a home with an EPC within recent years. The Danish survey is part of the European project IDEAL EPBD, which was funded by the European Commission under the Intelligent Energy Europe programme and run from 2008 to 2011. The results indicate a rather limited influence of the EPC on Danish homeowners' home energy renovation practices. Also, the results show that even though most homeowners find the label

  10. Verification of Generic Ubiquitous Middleware for Smart Home Using Coloured Petri Nets

    OpenAIRE

    Madhusudanan. J; Anand. P; Hariharan. S; V. Prasanna Venkatesan

    2014-01-01

    Smart home is a relatively new technology, where we applied pervasive computing in all the aspects, so as to make our jobs or things that we normally do in-side the home in a very easier way. Originally, a smart home technology was used to control environmental systems such as lighting and heating; but recently the use of smart technology has been developed so that almost any electrical component within the home can be included in the system. Usually in pervasive computing, a middleware is de...

  11. Measured Whole-House Performance of TaC Studios Test Home

    Energy Technology Data Exchange (ETDEWEB)

    Butler, T. [Partnership for Home Innovation (PHI), Upper Marlboro, MD (United States). Southface Energy Inst.; Curtis, O. [Partnership for Home Innovation (PHI), Upper Marlboro, MD (United States). Southface Energy Inst.; Stephenson, R. [Partnership for Home Innovation (PHI), Upper Marlboro, MD (United States). Southface Energy Inst.

    2013-12-01

    As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta-based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA in the mixed humid climate. This home serves as a residence and home office for the firm's owners, as well as a demonstration of their design approach topotential and current clients. Southface believes the home demonstrates current best practices for the mixed-humid climate, including a building envelope featuring advanced air sealing details and low density spray foam insulation, glazing that exceeds ENERGY STAR requirements, and a high performance heating and cooling system. Construction quality and execution was a high priority for TaCStudios and was ensured by a third party review process. Post-construction testing showed that the project met stated goals for envelope performance, an air infiltration rate of 2.15 ACH50. The homeowners wished to further validate whole house energy savings through the project's involvement with Building America and this long-term monitoring effort. As a Building America test home, this homewas evaluated to detail whole house energy use, end use loads, and the efficiency and operation of the ground source heat pump and associated systems. Given that the home includes many non-typical end use loads including a home office, pool, landscape water feature, and other luxury features not accounted for in Building America modeling tools, these end uses were separately monitored todetermine their impact on overall energy consumption.

  12. The changing character of household waste in the Czech Republic between 1999 and 2009 as a function of home heating methods

    International Nuclear Information System (INIS)

    Doležalová, Markéta; Benešová, Libuše; Závodská, Anita

    2013-01-01

    Highlights: • The character of household waste in the three different types of households were assesed. • The quantity, density and composition of household waste were determined. • The physicochemical characteristics were determined. • The changing character of household waste during past 10 years was described. • The potential of energy recovery of household waste in Czech republic was assesed. - Abstract: The authors of this paper report on the changing character of household waste, in the Czech Republic between 1999 and 2009 in households differentiated by their heating methods. The data presented are the result of two projects, financed by the Czech Ministry of Environment, which were undertaken during this time period with the aim of focusing on the waste characterisation and complete analysis of the physicochemical properties of the household waste. In the Czech Republic, the composition of household waste varies significantly between different types of households based on the methods of home heating employed. For the purposes of these studies, the types of homes were divided into three categories – urban, mixed and rural. Some of the biggest differences were found in the quantities of certain subsample categories, especially fine residue (matter smaller than 20 mm), between urban households with central heating and rural households that primarily employ solid fuel such coal or wood. The use of these solid fuels increases the fraction of the finer categories because of the higher presence of ash. Heating values of the residual household waste from the three categories varied very significantly, ranging from 6.8 MJ/kg to 14.2 MJ/kg in 1999 and from 6.8 MJ/kg to 10.5 MJ/kg in 2009 depending on the type of household and season. The same factors affect moisture of residual household waste which varied from 23.2% to 33.3%. The chemical parameters also varied significantly, especially in the quantities of Tl, As, Cr, Zn, Fe and Mn, which were higher in

  13. EPA Region 1 Coast Guard Jurisdictional Boundary - Polygons

    Data.gov (United States)

    U.S. Environmental Protection Agency — Jurisdictional boundary between EPA and Coast Guard for EPA Region I. Created from 1:100000 USGS DLGs with greater detail drawn from 1:24000 commercial street data...

  14. EPA Region 1 Coast Guard Jurisdictional Boundary - Arcs

    Data.gov (United States)

    U.S. Environmental Protection Agency — Jurisdictional boundary between EPA and Coast Guard for EPA Region I. Created from 1:100000 USGS DLGs with greater detail drawn from 1:24000 commercial street data...

  15. Career paths through the U.S. EPA

    Science.gov (United States)

    In a recent survey of employee satisfaction, the U.S. EPA was ranked 6th of the 30 large federal agencies that were surveyed (http://data.bestplacestowork.org). I have been working as a post doc at the EPA since receiving my Ph.D. in ecological physiology from the University of ...

  16. EPA Scientific Knowledge Management Assessment and ...

    Science.gov (United States)

    A series of activities have been conducted by a core group of EPA scientists from across the Agency. The activities were initiated in 2012 and the focus was to increase the reuse and interoperability of science software at EPA. The need for increased reuse and interoperability is linked to the increased complexity of environmental assessments in the 21st century. This complexity is manifest in the form of problems that require integrated multi-disciplinary solutions. To enable the means to develop these solutions (i.e., science software systems) it is necessary to integrate software developed by disparate groups representing a variety of science domains. Thus, reuse and interoperability becomes imperative. This report briefly describes the chronology of activities conducted by the group of scientists to provide context for the primary purpose of this report, that is, to describe the proceedings and outcomes of the latest activity, a workshop entitled “Workshop on Advancing US EPA integration of environmental and information sciences”. The EPA has been lagging in digital maturity relative to the private sector and even other government agencies. This report helps begin the process of improving the agency’s use of digital technologies, especially in the areas of efficiency and transparency. This report contributes to SHC 1.61.2.

  17. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Mittereder, Nick [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season.

  18. Heating ability and biocompatibility study of silica-coated magnetic ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 38; Issue 6. Heating ability and biocompatibility study of silica-coated magnetic nanoparticles as heating mediators for magnetic hyperthermia and magnetically triggered drug delivery systems. Meysam Soleymani Mohammad Edrissi. Volume 38 Issue 6 October 2015 ...

  19. EPA'S strategy to reduce risk of radon

    International Nuclear Information System (INIS)

    Page, S.

    1993-01-01

    The Indoor Radon Abatement Act of 1988 (IRAA) directed EPA to undertake a variety of activities to address the growing public concern over dangers posed by exposure to indoor radon. Among other requirements, the law directed the Agency to study radon levels, evaluate mitigation methods, establish proficiency programs, assist states with program development, develop training centers, and provide public information. EPA has developed and implemented programs to address each of the key provisions of this statute. This paper presents EPA's broad national strategy to reduce radon risks. It combines and reinforces EPA's basic foundation, including its guiding policies and cooperative partnerships, with an overall management approach and focus for the future. The paper starts with an overview that introduces the strategy's four key elements: underlying policies and scientific principles, a decentralized system of states and other partners for targeting the public, multiple strategies for achieving radon risk reduction, and a strong focus on five key program priorities. This paper then discusses each of these elements in more detail and describes how they interact to guide future efforts and directions of the Agency

  20. Nonattainment Areas in Louisiana, Geographic NAD83, EPA (2006) [Nonattainment_LA_EPA_2006

    Data.gov (United States)

    Louisiana Geographic Information Center — EPA Region 6 NonAttainment Areas in Louisiana, current as of May 2006. This shapefile contains parish boundaries and attributes that determine whether the parishes...

  1. Regulation of higher-activity NARM wastes by EPA

    International Nuclear Information System (INIS)

    Bandrowski, M.S.

    1988-01-01

    The US Environmental Protection Agency (EPA) is currently developing standards for the disposal of low-level radioactive waste (LLW). As part of this Standard, EPA is including regulations for the disposal of naturally occurring and accelerator-produced radioactive material (NARM) wastes not covered under the Atomic Energy Act (AEA). The regulations will cover only higher-activity NARM wastes, defined as NARM waste with specific activity exceeding two nanocuries per gram. The proposed regulations will specify that NARM wastes exceeding the above limits, except for specific exempted items, must be disposed of in regulated radioactive waste disposal facilities. The proposed EPA regulations for NARM wastes will be discussed, as well as the costs and benefits of the regulation, how it will be implemented by EPA, and the rationale for covering only higher-activity NARM wastes exceeding two nanocuries per gram

  2. EPA's Efforts in Eurasia

    Science.gov (United States)

    EPA has been collaborating with Russia, Central Asia, the Caucasus and Ukraine for over 20 years and continues to work with their governments and non-governmental organizations on environment, science and technology issues.

  3. DOE Zero Energy Ready Home Case Study: Boulder ZED Design Build - Boulder, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-11-01

    This case study describes a DOE Zero Energy Ready Home in Boulder, Colorado, that scored HERS 38 without PV and 0 with PV. This 2,504 ft2 custom home has advanced framed walls, superior insulation a ground-source heat pump, ERV, and triple-pane windows.

  4. EPA Region 1 Environmentally Sensitive Areas

    Science.gov (United States)

    This coverage represents polygon equivalents of environmentally sensitive areas (ESA) in EPA Region I. ESAs were developed as part of an EPA headquarters initiative based on reviews of various regulatory and guidance documents, as well as phone interviews with federal/state/local government agencies and private organizations. ESAs include, but are not limited to, wetlands, biological resources, habitats, national parks, archaeological/historic sites, natural heritage areas, tribal lands, drinking water intakes, marinas/boat ramps, wildlife areas, etc.

  5. 40 CFR 725.370 - EPA review of the TME application.

    Science.gov (United States)

    2010-07-01

    ... unreasonable risk of injury to health and the environment as a result of test marketing. ... Marketing § 725.370 EPA review of the TME application. General procedures for review of all submissions... with test marketing activities after receipt of EPA approval. (c) In approving a TME application, EPA...

  6. Infant otitis media and the use of secondary heating sources.

    Science.gov (United States)

    Pettigrew, Melinda M; Gent, Janneane F; Triche, Elizabeth W; Belanger, Kathleen D; Bracken, Michael B; Leaderer, Brian P

    2004-01-01

    This prospective study investigated the association of exposure to indoor secondary heating sources with otitis media and recurrent otitis media risk in infants. We enrolled mothers living in nonsmoking households and delivering babies between 1993 and 1996 in 12 Connecticut and Virginia hospitals. Biweekly telephone interviews during the first year of life assessed diagnoses from doctors' office visits and use of secondary home heating sources, air conditioner use, and day care. Otitis media episodes separated by more than 21 days were considered to be unique episodes. Recurrent otitis media was defined as 4 or more episodes of otitis media. Repeated-measures logistic regression modeling evaluated the association of kerosene heater, fireplace, or wood stove use with otitis media episodes while controlling for potential confounders. Logistic regression evaluated the relation of these secondary heating sources with recurrent otitis media. None of the secondary heating sources were associated with otitis media or with recurrent otitis media. Otitis media was associated with day care, the winter heating season, birth in the fall, white race, additional children in the home, and a maternal history of allergies in multivariate models. Recurrent otitis media was associated with day care, birth in the fall, white race, and a maternal history of allergies or asthma. We found no evidence that the intermittent use of secondary home heating sources increases the risk of otitis media or recurrent otitis media. This study confirms earlier findings regarding the importance of day care with respect to otitis media risk.

  7. Privacy Act System of Records: Invention Reports Submitted to the EPA, EPA-38

    Science.gov (United States)

    Learn about the Invention Reports Submitted to the EPA System, including who is covered in the system, the purpose of data collection, routine uses for the system's records, and other security procedures.

  8. US EPA CARE Grants

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is a provisional dataset that contains point locations for the subset of Community Action for a Renewed Environment (CARE) grants given out by the US EPA. CARE...

  9. US EPA EJ Grants

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is a provisional dataset that contains point locations for all Environmental Justice (EJ) grants given out by the US EPA. There are many limitations to the data...

  10. State and development prospects of district heating in the FRG

    International Nuclear Information System (INIS)

    Buch, A.

    1975-12-01

    The study outlines the state of district heating, investigates the preconditions of its increased application and determines the thus obtainable saving in energy consumption. The heat consumption in homes, the energy use and the types of heating for room heating and hot water supply, the covering of the demand for district heating, design of a district heating supply, the regional planning and the production costs of district heating are individually considered. The results are shown clearly in tables, maps and and graphs. (HR/LH) [de

  11. Cooperation and knowledge challenges in realizing smart homes: The case of small installer businesses

    NARCIS (Netherlands)

    Keijzer-Broers, W.J.W.; de Reuver, G.A.

    2016-01-01

    Despite technological advances, smart home concepts are not receiving widespread adoption. Small businesses that install and maintain heating, security and energy-saving systems could play a major role in bringing advanced technologies to home owners. However, the role of such small installer

  12. Brookfield Homes Passive House Performance Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Herk, A. [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, A. [IBACOS, Inc., Pittsburgh, PA (United States); Beach, R. [IBACOS, Inc., Pittsburgh, PA (United States)

    2016-02-04

    In 2012-2013, IBACOS worked with a builder, Brookfield Homes in Denver, Colorado, to design and construct a Passive House certified model home. IBACOS used several modeling programs and calculation methods to complete the final design package along with Brookfield's architect KGA Studio. This design package included upgrades to the thermal enclosure, basement insulation, windows, and heating, ventilation, and air conditioning. Short-term performance testing in the Passive House was done during construction and after construction. Testing with a blower door indicated that whole-building air leakage to the outside was 324 CFM and 0.60 ACH50. The other two test homes had little short-term testing done post-construction by the local energy rater. IBACOS then monitored the energy consumption and whole-house comfort conditions of that occupied Passive House after one year of operation and compared the monitoring results to those for two other occupied test houses in the same area with similar square footage but slightly different floor plans. IBACOS also assisted the builder, Brookfield Homes, in researching design scenarios for Zero Energy Ready Home and ENERGY STAR acceptance levels. IBACOS also assisted Brookfield in conceptualizing product for Denver's Brighton Heights area. Brookfield was considering building to Zero Energy Ready Home standards in that location. IBACOS provided strategies that Brookfield may draw from in the event the builder chooses to pursue a Zero Energy Ready Home plan for that market.

  13. Impact of Natural Gas Appliances on Pollutant Levels in California Homes

    Energy Technology Data Exchange (ETDEWEB)

    Mullen, Nasim A.; Li, Jina; Singer, Brett C.

    2012-12-01

    This report presents results from the first year of a 2-year study, investigating associations of five air pollutants (CO, NO2, NOX, formaldehyde and acetaldehyde) with the presence of natural gas appliances in California homes. From November 2011 to March 2012, pollutant concentration and occupant activity data were collected in 155 homes for 6-day periods. The sample population included both single-family (68%) and multi-family (32%) dwellings, with 87% having at least one gas appliance and 77% having an unvented gas cooking appliance. The geometric mean (GM) NO2 levels measured in the kitchen, bedroom and outside of homes were similar at values of 15, 12 and 11 ppb, respectively. In contrast, the GM NOx levels measured in the kitchen and bedroom of homes were much higher than levels measured outdoors, at levels of 42 and 41 ppb, compared to 19 ppb, respectively. Roughly 10% of sampled homes had 6-day average NO2 levels that exceeded the outdoor annual average limit set by the California Ambient Air Quality Standards (CAAQS) (30 ppb). The GMs of the highest 1-h and 8-h CO level measured in homes were 2.5 and 1.1 ppm, respectively. Four homes had a 1-h or 8-h concentration that exceeded the outdoor limits set by the CAAQS. The GM formaldehyde and acetaldehyde concentrations measured in homes were 15 and 7 ppb, respectively. Roughly 95% of homes had average formaldehyde levels indoors that exceeded the Chronic Reference Exposure Level set by the California EPA (7 ppb). Concentrations of NO2 and NOx, and to a lesser extent CO were associated with use of gas appliances, particularly unvented gas cooking appliances. Based on first principles, it is expected that effective venting of cooking pollutant emissions at the source will lead to a reduction of pollutant concentrations. However, no statistical association was detected between kitchen exhaust fan use and pollutant concentrations in homes in this study where gas cooking occurred frequently. The lack of

  14. Iowa state heating oil and propane program: 1996--1997 winter heating season. Final report

    International Nuclear Information System (INIS)

    1997-05-01

    The objective of the Iowa State Heating Oil and Propane Program is to develop a state-level, company-specific data collection effort so that retail price information on fuel oil and propane is collected by the staff of the Iowa Department of Natural Resources during the winter heating season. The second objective is to provide specific volume and retail price information to the US Department of Energy's (DOE's) Energy Information Administration on No. 2 heating oil and propane on a semi-monthly basis. This report summarizes the results of the residential No. 2 distillate fuel (home heating oil) and liquefied petroleum gas (propane) price survey over the 1996--1997 winter heating season in Iowa. The Iowa Department of Natural Resources conducted the survey under a cooperative financial assistance grant with the DOE Energy Information Administration (EIA)

  15. Science Inventory | US EPA

    Science.gov (United States)

    The Science Inventory is a searchable database of research products primarily from EPA's Office of Research and Development. Science Inventory records provide descriptions of the product, contact information, and links to available printed material or websites.

  16. Bio-Oil Deployment in the Home Heating Market

    Energy Technology Data Exchange (ETDEWEB)

    Butcher, T. A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Trojanowski, R. [Brookhaven National Lab. (BNL), Upton, NY (United States); Mante, O. [Brookhaven National Lab. (BNL), Upton, NY (United States); Wei, G. [Brookhaven National Lab. (BNL), Upton, NY (United States); Celebi, Y. [Brookhaven National Lab. (BNL), Upton, NY (United States); Huber, J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-07-01

    Distillate fuel oil is used in many stationary heating applications, predominantly in the Northeastern part of the United States. Total estimated non-transportation distillate use in 2014 was estimated to be 10.9 billion gallons. This study has focused on potentially displacing part of this petroleum use with biofuel derived from woody biomass. The fuel production route considered is pyrolysis which creates a liquid fuel high in oxygen, organic acids, and water. While this fuel can be used in stationary applications without significant further processing, to do so would require significant upgrades in current heating equipment. Alternatively this raw pyrolysis oil can be upgraded through catalytic hydrogenation to produce a bio-oil with near-negligible oxygen, water, and acidity. The focus of this work has been exploration of such upgraded fuels. The quality of upgraded fuels is affected by process conditions and there is a cost /quality tradeoff.

  17. Poster: Report Fraud Waste and Abuse to the EPA OIG Hotline

    Science.gov (United States)

    The EPA OIG hotline receives complaints of fraud, waste, and abuse in EPA and U.S. Chemical Safety Board programs and operations including mismanagement or violations of law, rules, or regulations by EPA employees or program participants.

  18. Collaborating with EPA through the Federal Technology Transfer Act

    Science.gov (United States)

    Under the Federal Technology Transfer Act (FTTA), EPA can collaborate with external parties on research projects, and share research materials. Learn more about the types of partnerships the EPA offers.

  19. Bio energy heating plant heats municipal buildings in Nord-Odal; Bioenergisentral varmer kommunale bygg i Nord-Odal

    Energy Technology Data Exchange (ETDEWEB)

    2008-07-01

    When Nord-Odal planned to build a new nursing home, they wanted to find a more environmental friendly heating system than based on oil and electricity. Several energy consultants evaluated the task. But when all consultants concluded there would be no cost benefit in this task, local experts looked into it - and because they got a long term agreement, it was possible to finance a local bio energy heat plant. (AG)

  20. Hispanos en la EPA: Elias Rodríguez

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  1. Hispanos en la EPA: Sally Gutiérrez

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  2. EPA's Revised Interim Financial Assistance Conflict of Interest Policy

    Science.gov (United States)

    EPA has established the following revised interim policy governing disclosure of actual and potential conflicts of interest (COI Policy) by applicants for, and recipients of, federal financial assistance awards from EPA.

  3. IG Statement: Arthur A. Elkins, Jr., on OIG report Early Warning Report: Main EPA Headquarters Warehouse in Landover, Maryland, Requires Immediate EPA Attention

    Science.gov (United States)

    Statement of Inspector General Arthur A. Elkins, Jr., on the Office of Inspector General (OIG) report Early Warning Report: Main EPA Headquarters Warehouse in Landover, Maryland, Requires Immediate EPA Attention.

  4. Airborne exposure to trihalomethanes from tap water in homes with refrigeration-type and evaporative cooling systems.

    Science.gov (United States)

    Kerger, Brent D; Suder, David R; Schmidt, Chuck E; Paustenbach, Dennis J

    2005-03-26

    This study evaluates airborne concentrations of common trihalomethane compounds (THM) in selected living spaces of homes supplied with chlorinated tap water containing >85 ppb total THM. Three small homes in an arid urban area were selected, each having three bedrooms, a full bath, and approximately 1000 square feet; two homes had standard (refrigeration-type) central air conditioning and the third had a central evaporative cooling system ("swamp cooler"). A high-end water-use pattern was used at each home in this exposure simulation. THM were concurrently measured on 4 separate test days in tap water and air in the bathroom, living room, the bedroom closest to the bathroom, and outside using Summa canisters. Chloroform (trichloromethane, TCM), bromodichloromethane (BDCM), and dibromochloromethane (DBCM) concentrations were quantified using U.S. EPA Method TO-14. The apparent volatilization fraction consistently followed the order: TCM > BDCM > DBCM. Relatively low airborne THM concentrations (similar to outdoors) were found in the living room and bedroom samples for the home with evaporative cooling, while the refrigeration-cooled homes showed significantly higher THM levels (three- to fourfold). This differential remained after normalizing the air concentrations based on estimated THM throughput or water concentrations. These findings indicate that, despite higher throughput of THM-containing water in homes using evaporative coolers, the higher air exchange rates associated with these systems rapidly clears THM to levels similar to ambient outdoor concentrations.

  5. EPA Region 1 Coast Guard Jurisdictional Boundary - Polygons

    Science.gov (United States)

    Jurisdictional boundary between EPA and Coast Guard for EPA Region I. Created from 1:100000 USGS DLGs with greater detail drawn from 1:24000 commercial street data for Region I.This layer is used to determine which agency will be reponsible in the event of an oil spill.

  6. EPA Region 1 Coast Guard Jurisdictional Boundary - Arcs

    Science.gov (United States)

    Jurisdictional boundary between EPA and Coast Guard for EPA Region I. Created from 1:100000 USGS DLGs with greater detail drawn from 1:24000 commercial street data for Region I.This layer is used to determine which agency will be reponsible in the event of an oil spill.

  7. Notification: EPA Investments in Information Technology Products and Services

    Science.gov (United States)

    Project #OA-FY14-0307, June 10, 2014. The U.S. Environmental Protection Agency (EPA) Office oflnspector General (OIG) plans to begin preliminary research on the EPA's management of information technology (IT) investments.

  8. US EPA's Ecological Risk Assessment Support Center ...

    Science.gov (United States)

    BackgroundThe ERASC provides technical information and addresses scientific questions of concern or interest on topics relevant to ecological risk assessment at hazardous waste sites for EPA's Office of Solid Waste and Emergency Response (OSWER) personnel and the Office of Resource Conservation and Recovery (ORCR) staff. Requests are channeled to ERASC through the Ecological Risk Assessment Forum (ERAF). To assess emerging and complex scientific issues that require expert judgment, the ERASC relies on the expertise of scientists and engineers located throughout EPA's Office of Research and Development (ORD) labs and centers.ResponseERASC develops responses that reflect the state of the science for ecological risk assessment and also provides a communication point for the distribution of the responses to other interested parties. For further information, contact Ecology_ERASC@epa.gov or call 513-569-7940.

  9. 77 FR 10373 - Greenhouse Gas Reporting Program: Electronics Manufacturing: Revisions to Heat Transfer Fluid...

    Science.gov (United States)

    2012-02-22

    ... Greenhouse Gas Reporting Program: Electronics Manufacturing: Revisions to Heat Transfer Fluid Provisions... technical revisions to the electronics manufacturing source category of the Greenhouse Gas Reporting Rule... final rule will also be available through the WWW on the EPA's Greenhouse Gas Reporting Program Web site...

  10. In-home performance of pellet stoves in Medford and Klamath Falls, Oregon

    International Nuclear Information System (INIS)

    Barnett, S.G.; Houck, J.E.; Roholt, R.B.

    1991-01-01

    Pollutant emissions, thermal efficiencies, and heat outputs of pellet stoves operating in homes located in Klamath Falls and Medford, Oregon were documented. Six stoves representing two commercially available, certified models were studied during the 1989-1990 heating season. Three models exempt from certification (a total of six stoves) were studied during the 1990-1991 heating season. An automated emission sampler (AES) system was used to conduct long-term, in-home monitoring of the stoves. The results of the studies have permitted an evaluation of the environmental and energy performance characteristics of the stoves. For the certified stoves, the average overall particulate emissions were 1.05 grams per hour (g/hr), which is about 75% lower than the best-performing cordwood stoves. The in-home particulate emission values were close to their laboratory certification values. Preliminary results for the exempt stoves produced an average particulate emission value of 2.02 g/hr. Also, for the certified stoves, altitude appeared to have little or no effect on particulate emissions and there appeared to be no differences in particulate emission rates between the two models studied. Polycyclic aromatic hydrocarbon (PAH) and carbon monoxide emissions were low. The carbon monoxide emission rates averaged 14 g/hr, the average net thermal efficiency of the stoves was 68%, and the average heat output was 8,747 Btu per hour. Similar data are currently being evaluated for the exempt stoves. Emission and energy performance data obtained for the pellet stoves assessed in this study demonstrated that pellet stoves offer a viable residential biomass-fueled heating option

  11. Optimal synthesis and operation of advanced energy supply systems for standard and domotic home

    International Nuclear Information System (INIS)

    Buoro, Dario; Casisi, Melchiorre; Pinamonti, Piero; Reini, Mauro

    2012-01-01

    Highlights: ► Definition of an optimization model for a home energy supply system. ► Optimization of the energy supply system for standard and domotic home. ► Strong improvement can be achieved adopting the optimal system in standard and domotic home. ► The improvements are consistent if supply side and demand side strategies are applied together. ► Solutions with internal combustion engines are less sensible to market price of electricity and gas. - Abstract: The paper deals with the optimization of an advanced energy supply systems for two dwellings: a standard home and an advanced domotic home, where some demand side energy saving strategies have been implemented. In both cases the optimal synthesis, design and operation of the whole energy supply system have been obtained and a sensitivity analysis has been performed, by introducing different economic constraints. The optimization model is based on a Mixed Integer Linear Program (MILP) and includes different kinds of small-scale cogenerators, geothermal heat pumps, boilers, heat storages, solar thermal and photovoltaic panels. In addition, absorption machines, supplied with cogenerated heat, can be used instead of conventional electrical chiller to face the cooling demand. The aim of the analysis is to address the question if advanced demand strategies and supply strategies have to be regarded as alternatives, or if they have to be simultaneously applied, in order to obtain the maximum energy and economic benefit.

  12. EPA Web Training Classes

    Science.gov (United States)

    Scheduled webinars can help you better manage EPA web content. Class topics include Drupal basics, creating different types of pages in the WebCMS such as document pages and forms, using Google Analytics, and best practices for metadata and accessibility.

  13. DOE ZERH Case Study: Carl Franklin Homes, L.C./Green Extreme Homes, CDC, McKinley Project, Garland TX

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2015-09-01

    Case study of a DOE 2015 Housing Innovation Award winning affordable home in the hot-humid climate that got a HERS 56 without PV or HERS 26 with PV, with 4.5” SIP walls and 8.5” SIP roof; uninsulated slab; ductless minisplit heat pump 15.5 SEER, and tankless hot water.

  14. Discover the benefits of residential wood heating

    International Nuclear Information System (INIS)

    2003-01-01

    This publication described how residential wood-heating systems are being used to reduce energy costs and increase home comfort. Biomass energy refers to all forms are renewable energy that is derived from plant materials. The source of fuel may include sawmills, woodworking shops, forest operations and farms. The combustion of biomass is also considered to be carbon dioxide neutral, and is not considered to be a major producer of greenhouse gases (GHG) linked to global climate change. Wood burning does, however, release air pollutants, particularly if they are incompletely burned. Incomplete combustion of wood results in dense smoke consisting of toxic gases. Natural Resources Canada helped create new safety standards and the development of the Wood Energy Technical Training Program to ensure that all types of wood-burning appliances are installed correctly and safely to reduce the risk of fire and for effective wood heating. In Canada, more than 3 million families heat with wood as a primary or secondary heating source in homes and cottages. Wood heating offers security from energy price fluctuations and electrical power failures. This paper described the benefits of fireplace inserts that can transform old fireplaces into modern heating systems. It also demonstrated how an add-on wood furnace can be installed next to oil furnaces to convert an oil-only heating system to a wood-oil combination system, thereby saving thousands of dollars in heating costs. Wood pellet stoves are another wood burning option. The fuel for the stoves is produced from dried, finely ground wood waste that is compressed into hard pellets that are loaded into a hopper. The stove can run automatically for up to 24 hours. New high-efficiency advanced fireplaces also offer an alternative heating system that can reduce heating costs while preserving Canada's limited supply of fossil fuels such as oil and gas. 13 figs

  15. Solar Energy: Uses for Your Home. The CIRcular: Consumer Information Report 15.

    Science.gov (United States)

    Bank of America NT & SA, San Francisco, CA.

    This report defines active and passive solar energy systems, describes home uses for solar energy, and offers guidelines for choosing and installing a system. Much of the information is specific to the state of California. Uses for solar energy which are presented include passive space heating, passive cooling, active space heating, household…

  16. Manufactured Home Energy Audit (MHEA)Users Manual (Version 7)

    Energy Technology Data Exchange (ETDEWEB)

    Gettings, M.B.

    2003-01-27

    The Manufactured Home Energy Audit (MHEA) is a software tool that predicts manufactured home energy consumption and recommends weatherization retrofit measures. It was developed to assist local weatherization agencies working with the U.S. Department of Energy (DOE) Weatherization Assistance Program. Whether new or experienced, employed within or outside the Weatherization Assistance Program, all users can benefit from incorporating MHEA into their manufactured home weatherization programs. DOE anticipates that the state weatherization assistance programs that incorporate MHEA into their programs will find significant growth in the energy and cost savings achieved from manufactured home weatherization. The easy-to-use MHEA uses a relatively standard Windows graphical interface for entering simple inputs and provides understandable, usable results. The user enters information about the manufactured home construction, heating equipment, cooling equipment appliances, and weather site. MHEA then calculates annual energy consumption using a simplified building energy analysis technique. Weatherization retrofit measures are evaluated based on the predicted energy savings after installation of the measure, the measure cost, and the measure life. Finally, MHEA recommends retrofit measures that are energy and cost effective for the particular home being evaluated. MHEA evaluates each manufactured home individually and takes into account local weather conditions, retrofit measure costs, and fuel costs. The recommended package of weatherization retrofit measures is tailored to the home being evaluated. More traditional techniques apply the same package of retrofit measures to all manufactured homes, often the same set of measures that are installed into site-built homes. Effective manufactured home weatherization can be achieved only by installing measures developed specifically for manufactured homes. The unique manufactured home construction characteristics require that

  17. Drivers and barriers to heat stress resilience.

    Science.gov (United States)

    Hatvani-Kovacs, Gertrud; Belusko, Martin; Skinner, Natalie; Pockett, John; Boland, John

    2016-11-15

    Heatwaves are the most dangerous natural hazard to health in Australia. The frequency and intensity of heatwaves will increase due to climate change and urban heat island effects in cities, aggravating the negative impacts of heatwaves. Two approaches exist to develop population heat stress resilience. Firstly, the most vulnerable social groups can be identified and public health services can prepare for the increased morbidity. Secondly, the population level of adaptation and the heat stress resistance of the built environment can be increased. The evaluation of these measures and their efficiencies has been fragmented across research disciplines. This study explored the relationships between the elements of heat stress resilience and their potential demographic and housing drivers and barriers. The responses of a representative online survey (N=393) about heat stress resilience at home and work from Adelaide, South Australia were analysed. The empirical findings demonstrate that heat stress resistant buildings increased adaptation capacity and decreased the number of health problems. Air-conditioning increased dependence upon it, limited passive adaptation and only people living in homes with whole-house air-conditioning had less health problems during heatwaves. Tenants and respondents with pre-existing health conditions were the most vulnerable, particularly as those with health conditions were not aware of their vulnerability. The introduction of an Energy Performance Certificate is proposed and discussed as an effective incentive to increase the heat stress resistance of and the general knowledge about the built environment. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Notification: Audit of Certain EPA Electronic Records Management Practices

    Science.gov (United States)

    Project #OA-FY13-0113, December 13, 2012. This memorandum is to notify you that the U.S. Environmental Protection Agency (EPA), Office of Inspector General, plans to begin an audit of certain EPA electronic records management practices.

  19. 40 CFR 600.109-78 - EPA driving cycles.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false EPA driving cycles. 600.109-78 Section... Model Year Automobiles-Test Procedures § 600.109-78 EPA driving cycles. (a) The driving cycle to be... driving cycle to be utilized for generation of the highway fuel economy data is specified in this...

  20. CO2 emissions reduction using energy conservation measures: EPA Region IV's experience

    International Nuclear Information System (INIS)

    Berish, C.; Day, R.; Sibold, K.; Tiller, J.

    1994-01-01

    EPA Region 4 concluded in a recent comparative environmental risk evaluation that global climate change could substantially impact the Southeast. To address this risk, Region 4 developed an action plan to promote cost-effective pollution prevention and reduce greenhouse gas emissions, The regional plan contains programs that aye specific to Region 4 as well as geographic components of the national Climate Change Action Plan. Sources of carbon dioxide emissions were targeted for pollution prevention based on an energy model that allows the user to create energy efficiency scenarios in four sectors: residential, commercial, industrial, and transportation. Activities were selected using the modeled information on sector reduction potentials and resource and cost-effectiveness criteria. Given the high level of uncertainty associated with climate change projections, the programs developed are all cost effective, prevent pollution and/or result in sound adaptation policies. Currently, policy makers at national, regional, and local levels are deciding on what types of energy efficiency programs to implement. The region's action plan is composed of several programs and approaches. The authors have developed implemented, and/or participated in the following: energy scenario model. EARTHWALK (residential energy conservation); energy conservation in affordable homes (new residences); Cool Communities Program (strategic tree planting and light colored surfaces); EPA's Green Lights Program; WAVE (water conservation), the Plant Protection Center; QUEST TO SAVE THE EARTH (outreach tools); energy and water use planning for the 1996 Olympic Games, and planning for sea-level rise. Reviewing the practices of the above programs will be the focus of this paper

  1. EPA Collaboration with South Korea

    Science.gov (United States)

    EPA, the Ministry of Environment of Korea, and partner agencies in both countries cooperate to strengthen environmental governance, improve air and water quality, and reduce exposure to toxic chemicals.

  2. Coping with heat in the city: what can we learn from a survey immediately after a hot weather period for future heat waves?

    Science.gov (United States)

    Kunz-Plapp, Tina; Schipper, Hans; Hackenbruch, Julia

    2015-04-01

    Karlsruhe is one of the hottest cities in Germany with a temperature record of 40.2°C in August 2003. In 2013, two hot weather periods with continuous heat warnings by the German Weather Service for 7 and 8 days occurred during the second half of July and first 10 days of August 2013, and in early August the temperatures in Karlsruhe almost reached again the record of 40.2°C. To understand how citizens experienced the heat and what strategies they used to cope with the heat, we conducted a questionnaire survey on subjective heat stress and coping strategies immediately after the hot weather period. Based on a holistic approach the questionnaire included questions on heat stress experience in different contexts of daily life, health impacts of the heat, coping measures, housing conditions, urban environment, living conditions, and socio-demographic characteristics. The responses of the 323 survey participants living and working in Karlsruhe show that they on average experienced the heat as rather stressful event, whereby the heat stress experienced at home was significant lower than heat stress experienced at work or in general. Regression analyses show that, among the factors included in the questionnaire, the health impairments suffered during the heat, the control belief and the coping measures implemented mainly determine heat stress experienced in general and at work. For the subjective heat stress at home, factors of the built urban environment such as heat loading of district, living in the attic or the ground floor, and heat protection elements of the inhabited building also played a role. At the same time, the way the respondents used different coping strategies in context of their daily activities and routines during heat suggests lessons to learn from this event how individual response to heat differs from responses to other types of natural hazards.

  3. 40 CFR 2.205 - Final confidentiality determination by EPA legal office.

    Science.gov (United States)

    2010-07-01

    ..., after consideration of any timely comments submitted by the business, the EPA legal office makes a... is made by the business and approved by the EPA legal office. Except in extraordinary circumstances... determinations; matters to be considered. (1) If the EPA legal office finds that a business has failed to furnish...

  4. Market Potential for Residential Biomass Heating Equipment: Stochastic and Econometric Assessments

    OpenAIRE

    Adee Athiyaman

    2015-01-01

    This paper provides estimates of market potential for biomass-residential-heating equipment in the US: that is, the greatest amount of biomass-residential-heating equipment that can be sold by the industry. The author's analysis is limited to biomass equipment used most to heat the housing unit. Assuming that households equipped with 10+ year old primary heating devices will replace rather than repair the devices he predicts that approximately 1.4 million units of residential home heating equ...

  5. Factors affecting radon levels in homes in British Columbia, Canada

    International Nuclear Information System (INIS)

    Morley, D.R.; Phillips, B.G.; Van Netten, C.

    1992-01-01

    British Columbia, Canada's most westerly province, has diverse geologic and climatic characteristics, making it a region where predicting radon gas level is quite complex. Data recently obtained for eleven (11) communities confirm an association between background terrestrial gamma radiation measurements and indoor radon levels in homes. Direct links between radon levels and other factors such as home design/construction features and heating/ventilation systems were observed in data for some communities, but not necessarily from the overall data. (author)

  6. Work-In-Progress Peer Consult on EPA's Multimedia ...

    Science.gov (United States)

    This document is a compilation of responses from four external peer reviewers on EPA's "Multimedia Exposure Analysis to Inform a Public Health-Based Value for Lead in Drinking Water." It was delivered by Versar, Inc. under contract number EP-C-12-045 Task Order 91. Peer review report compiled, written and delivered by Versar, Inc to EPA.

  7. 40 CFR 600.109-08 - EPA driving cycles.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false EPA driving cycles. 600.109-08 Section... Model Year Automobiles-Test Procedures § 600.109-08 EPA driving cycles. (a) The FTP driving cycle is prescribed in § 86.115 of this chapter. (b) The highway fuel economy driving cycle is specified in this...

  8. National Air Toxics Assessment - 2005, EPA Region 2 (EPA.AIR.NATA99_R2)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data layer is based on the model results of the 1999 National-Scale Assessment (N-SA), a part of the National Air Toxics Assessment (NATA), conducted by EPA's...

  9. National Air Toxics Assessment - 2002, EPA Region 2 (EPA.AIR.NATA99_R2)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data layer is based on the model results of the 1999 National-Scale Assessment (N-SA), a part of the National Air Toxics Assessment (NATA), conducted by EPA's...

  10. National Air Toxics Assessment - 1999, EPA Region 2 (EPA.AIR.NATA99_R2)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data layer is based on the model results of the 1999 National-Scale Assessment (N-SA), a part of the National Air Toxics Assessment (NATA), conducted by EPA's...

  11. CISBAT 2007 - Solar collectors (heat and electricity)

    International Nuclear Information System (INIS)

    2007-01-01

    This is the third part of the proceedings of the 2007 CISBAT conference on Renewables in a changing climate, held in Lausanne, Switzerland. On the subject of Building and urban integration of renewables the following oral contributions are summarised: 'Facade integration of solar thermal collectors: present and future', 'Long term experiences with a versatile PV in roof system', 'Development of a design and performance prediction tool for the ground source heat pump and underground thermal storage system', 'Hygrothermal performance of earth-to-air heat exchanger: long-term data evaluation and short-term simulation' as well as 'The real cost of heating your home: a comparative assessment of home energy systems with external costs'. Poster-sessions on the subject include 'Central solar heating plants with seasonal heat storage', 'Analysis of forced convection for evaporative air flow and heat transfer in PV cooling channels', 'Renewable energy technology in Mali: constraints and options for a sustainable development', 'Effect of duct width in ducted photovoltaic facades', 'Design and actual measurement of a ground source heat pump system using steel foundation piles as ground heat exchangers', 'Development of an integrated water-water heat pump unit for low energy house and its application', 'PV effect in multilayer cells and blending of fullerene/poly (3-hexylthiophene) and phthalocyanine having NIR charge transfer absorption band', 'CdTe photovoltaic systems - an alternative energetic', 'Integration of renewable energy sources in a town, examples in Grenoble', 'A prospective analysis method for the conception of solar integration solutions in buildings' and 'Energy and aesthetic improvements for building integration of cost effective solar energy systems'. Further groups of presentations at the conference are reported on in separate database records. An index of authors completes the proceedings

  12. The relation between the omega-3 index and arachidonic acid is bell shaped : Synergistic at low EPA plus DHA status and antagonistic at high EPA plus DHA status

    NARCIS (Netherlands)

    Luxwolda, Martine F.; Kuipers, Remko S.; Smit, Ella N.; Velzing-Aarts, Francien V.; Dijck-Brouwer, D. A. Janneke; Muskiet, Frits A. J.

    2011-01-01

    Introduction: The relation between docosahexaenoic (DHA) and eicosapentaenoic (EPA) vs. arachidonic acid (AA) seems characterized by both synergism and antagonism. Materials and methods: Investigate the relation between EPA + DHA and AA in populations with a wide range of EPA + DHA status and across

  13. Evaluation of the Impact of Slab Foundation Heat Transfer on Heating and Cooling in Florida

    Energy Technology Data Exchange (ETDEWEB)

    Parker, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Kono, J. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Vieira, R. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Gu, L. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)

    2016-09-01

    During the last three decades of energy-efficiency research, there has been limited study of heat transfer to slab-on-grade foundations in cooling-dominated climates. Most experimental research has focused on the impact of slab-on-grade foundations and insulation schemes on heat losses in heating-dominated climates. This is surprising because the floor area in single-family homes is generally equal to wall area, window area, or attic area, all of which have been extensively evaluated for heat-transfer properties. Moreover, slab foundations are the most common foundation type in cooling-dominated climates. Slab-on-grade construction is very popular in southern states, accounting for 77% of new home floors according to 2014 U.S. Census data. There is a widespread perception that tile flooring, as opposed to carpet, provides a cooler home interior in warm climates. Empirical research is needed because building energy simulation software programs running DOE-2 and EnergyPlus engines often rely on simplified models to evaluate the influence of flooring on interior temperature, even though in some cases more detailed models exist. The U.S. Department of Energy Building America Partnership for Improved Residential Construction (BA-PIRC) performed experiments in the Florida Solar Energy Center’s Flexible Residential Test Facility intended to assess for the first time (1) how slab-on-grade construction influences interior cooling in a cooling-dominated climate and (2) how the difference in a carpeted versus uncarpeted building might influence heating and cooling energy use. Two nominally identical side-by-side residential buildings were evaluated during the course of 1 year, from 2014 to 2015: the east building with a pad and carpet floor and the west building with a bare slab floor. A detailed grid shows temperature measurements taken on the slab surface at various locations as well as at depths of 1.0 ft, 2 ft, 5.0 ft, 10.0 ft, and 20.0 ft below the surface. Temperature

  14. EPA RE-Powering Screening Shapefile

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Center for Program Analysis (CPA) initiated the RE-Powering America’s...

  15. Modifying EPA radiation risk models based on BEIR VII

    International Nuclear Information System (INIS)

    Pawel, D.; Puskin, J.

    2007-01-01

    This paper summarizes a 'draft White Paper' that provides details on proposed changes in EPA's methodology for estimating radiogenic cancer risks. Many of the changes are based on the contents of a recent National Academy of Sciences (NAS) report (BEIR VII), that addresses cancer and genetic risks from low doses of low-LET radiation. The draft White Paper was prepared for a meeting with the EPA's Science Advisory Board's Radiation Advisory Committee (RAC) in September for seeking advice on the application of BEIR VII and on issues relating to these modifications and expansions. After receiving the Advisory review, we plan to implement the changes by publishing the new methodology in an EPA report, which we expect to submit to the RAC for final review. The revised methodology could then be applied to update the cancer risk coefficients for over 800 radionuclides that are published in EPA's Federal Guidance Report 13. (author)

  16. EPA's Green Roof Research

    Science.gov (United States)

    This is a presentation on the basics of green roof technology. The presentation highlights some of the recent ORD research projects on green roofs and provices insight for the end user as to the benefits for green roof technology. It provides links to currently available EPA re...

  17. EPA's Radioactive Source Program

    International Nuclear Information System (INIS)

    Kopsick, D.

    2004-01-01

    The US EPA is the lead Federal agency for emergency responses to unknown radiological materials, not licensed, owned or operated by a Federal agency or an Agreement state (Federal Radiological Emergency Response Plan, 1996). The purpose of EPA's clean materials programme is to keep unwanted and unregulated radioactive material out of the public domain. This is achieved by finding and securing lost sources, maintaining control of existing sources and preventing future losses. The focus is on both, domestic and international fronts. The domestic program concentrates on securing lost sources, preventing future losses, alternative technologies like tagging of radioactive sources in commerce, pilot radioactive source roundup, training programs, scrap metal and metal processing facilities, the demolition industry, product stewardship and alternatives to radioactive devices (fewer radioactive source devices means fewer orphan sources). The international program consists of securing lost sources, preventing future losses, radiation monitoring of scrap metal at ports and the international scrap metal monitoring protocol

  18. Green Roof Research through EPA's Regional Applied Research Effort

    Science.gov (United States)

    ABSTRACT The U.S. Environmental Protection Agency’s (EPA) Regional Applied Research Effort (RARE) allows the Regions of the EPA to choose research projects to be performed in partnership with EPA’s Office of Research and Development (ORD). Over the last decade, several green roo...

  19. Enforcement Alert: Hazardous Waste Management Practices at Mineral Processing Facilities Under Scrutiny by U.S. EPA; EPA Clarifies 'Bevill Exclusion' Wastes and Establishes Disposal Standards

    Science.gov (United States)

    This is the enforcement alert for Hazardous Waste Management Practices at Mineral Processing Facilities Under Scrutiny by U.S. EPA; EPA Clarifies 'Bevill Exclusion' Wastes and Establishes Disposal Standards

  20. Hispanos en la EPA: Rafael DeLeón

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  1. US EPA's SPECIATE 4.4 Database: Development and Uses

    Science.gov (United States)

    SPECIATE is the U.S. Environmental Protection Agency’s (EPA) repository of volatile organic gas and particulate matter (PM) speciation profiles of air pollution sources. EPA released SPECIATE 4.4 in early 2014 and, in total, the SPECIATE 4.4 database includes 5,728 PM, volatile o...

  2. 40 CFR 74.10 - Roles-EPA and permitting authority.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Roles-EPA and permitting authority. 74... (CONTINUED) SULFUR DIOXIDE OPT-INS Permitting Procedures § 74.10 Roles—EPA and permitting authority. (a... end-of-year compliance, determining reduced utilization, approving thermal energy transfer and...

  3. EPA Nonregulatory Nonroad Duty Cycles

    Science.gov (United States)

    EPA nonregulatory, nonroad duty cycles for equipment such as agricultural tractors, backhoe loaders,crawlers tractors, excavators, arc welding skid steer loaders, and wheel loaders. Also,test procedures, laboratory methods, and emissions for this equipmen

  4. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Mittereder, N.; Poerschke, A.

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season. Upon completion of the monitoring phase, measurements revealed that the initial TRNSYS simulated horizontal sub-slab ground loop heat exchanger fluid temperatures and heat transfer rates differed from the measured values. To determine the cause of this discrepancy, an updated model was developed utilizing a new TRNSYS subroutine for simulating sub-slab heat exchangers. Measurements of fluid temperature, soil temperature, and heat transfer were used to validate the updated model.

  5. Greenbelt Homes Pilot Program. Summary of Building Envelope Retrofits, Planned HVAC Equipment Upgrades, and Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Wiehagen, J. [Home Innovation Research Labs, Marlboro, MD (United States); Del Bianco, M. [Home Innovation Research Labs, Marlboro, MD (United States); Mallay, D. [Home Innovation Research Labs, Marlboro, MD (United States)

    2015-05-22

    The U.S. Department of Energy Building America team Partnership for Home Innovation wrote a report on Phase 1 of the project that summarized a condition assessment of the homes and evaluated retrofit options within the constraints of the cooperative provided by GHI. Phase 2 was completed following monitoring in the 2013–2014 winter season; the results are summarized in this report. Phase 3 upgrades of heating equipment will be implemented in time for the 2014–2015 heating season and are not part of this report.

  6. System Security And Monitoring On Smart Home Using Android

    Science.gov (United States)

    Romadhon, A. S.

    2018-01-01

    Home security system is needed for homeowners who have a lot of activities, as a result, they often leave the house without locking the door and even leave the house in a state of lights that are not lit. In order to overcome this case, a system that can control and can monitor the state of the various devices contained in the house or smart home system is urgently required. The working principle of this smart home using android is when the homeowner sends a certain command using android, the command will be forwarded to the microcontroller and then it will be executed based on the parameters that have been determined. For example, it can turn off and on the light using android app. In this study, testing was conducted to a smart home prototype which is equipped with light bulbs, odour sensors, heat sensors, ultrasonic sensors, LDR, buzzer and camera. The test results indicate that the application has been able to control all the sensors of home appliances well.

  7. Clean energy choices: Tips on buying and using renewable energy at home

    International Nuclear Information System (INIS)

    NREL

    2000-01-01

    This brochure provides information on how consumers can use renewable energy in and around the home. Information on buying green power; using renewables to generate power; using passive and active solar and geothermal heat pumps to heat, cool and light buildings; and using alternative fuels and vehicles is included. Resources at the end of each chapter help readers find more information

  8. Clean energy choices: Tips on buying and using renewable energy at home

    Energy Technology Data Exchange (ETDEWEB)

    NREL

    2000-04-07

    This brochure provides information on how consumers can use renewable energy in and around the home. Information on buying green power; using renewables to generate power; using passive and active solar and geothermal heat pumps to heat, cool and light buildings; and using alternative fuels and vehicles is included. Resources at the end of each chapter help readers find more information.

  9. EPA`s program for risk assessment guidelines: Quantification issues

    Energy Technology Data Exchange (ETDEWEB)

    Dourson, M.L. [Environmental Protection Agency, Washington, DC (United States)

    1990-12-31

    The quantitative procedures associated with noncancer risk assessment include reference dose (RfD), benchmark dose, and severity modeling. The RfD, which is part of the EPA risk assessment guidelines, is an estimation of a level that is likely to be without any health risk to sensitive individuals. The RfD requires two major judgments: the first is choice of a critical effect(s) and its No Observed Adverse Effect Level (NOAEL); the second judgment is choice of an uncertainty factor. This paper discusses major assumptions and limitations of the RfD model.

  10. Northwest Energy Efficient Manufactured Housing Program High-Performance Test Homes

    Energy Technology Data Exchange (ETDEWEB)

    Hewes, Tom; Peeks, Brady

    2015-09-15

    ?This project represents the third phase of a multi-year effort to develop and bring to market a High Performance Manufactured Home (HPMH). The scope of this project involved building four HPMH prototypes, resulting in what is expected to be a 30% savings relative to the Building America Benchmark. (The actual % savings varies depending on choice of heating equipment and climate zone). The HPMH home is intended to make significant progress toward performing as zero-net-energy ready. Previous phases of this project created a HPMH specification and prototyped individual measures from the package to obtain engineering approvals and develop preliminary factory construction processes. This report describes the project team's work during 2014 to build prototype homes to the HPMH specifications and to monitor the homes for energy performance and durability during 2014. Monitoring is expected to continue into 2016.

  11. Memorandum of Understanding Between U.S. EPA Superfund and U.S. NRC

    International Nuclear Information System (INIS)

    Walker, Stuart

    2008-01-01

    The Environmental Protection Agency (EPA) Office of Superfund Remediation and Technology Innovation (OSRTI) and the Nuclear Regulatory Commission (NRC) are responsible for implementing the 'Memorandum of Understanding Between the Environmental Protection Agency and the Nuclear Regulatory Commission: Consultation and Finality on Decommissioning and Decontamination of Contaminated Sites'. This paper provides a brief overview of the origin of the Memorandum of Understanding (MOU), the major features of the MOU, and how the MOU has been implemented site specifically. EPA and NRC developed the MOU in response to direction from the House Committee on Appropriations to EPA and NRC to work together to address the potential for dual regulation. The MOU was signed by EPA on September 30, 2002 and NRC on October 9, 2002. The two agencies had worked on the MOU since March 2000. While both EPA and NRC have statutory authority to clean up these sites, the MOU provides consultation procedures between EPA and NRC to eliminate dual regulation. Under the MOU, EPA and NRC identified the interactions of the two agencies for the decommissioning and decontamination of NRC-licensed sites and the ways in which those responsibilities will be exercised. Except for Section VI, which addresses corrective action under the Resource Conservation and Recovery Act (RCRA), this MOU is limited to the coordination between EPA, when acting under its CERCLA authority, and NRC, when a facility licensed by the NRC is undergoing decommissioning, or when a facility has completed decommissioning, and the NRC has terminated its license. EPA believes that implementation of the MOU between the two agencies will ensure that future confusion about dual regulation does not occur regarding the cleanup and reuse of NRC-licensed sites. NRC and EPA have so far exchanged MOU consultation letters on eight NRC-licensed sites. EPA has responded to each consultation request with a letter expressing its views on actions

  12. Supplementation of docosahexaenoic acid (DHA) / Eicosapentaenoic acid (EPA) in a ratio of 1/1.3 during the last trimester of pregnancy results in EPA accumulation in cord blood.

    Science.gov (United States)

    Büyükuslu, Nihal; Ovalı, Sema; Altuntaş, Şükriye Leyla; Batırel, Saime; Yiğit, Pakize; Garipağaoğlu, Muazzez

    2017-10-01

    Omega-3 fatty acids (n-3 FA), specifically DHA, are associated with fetal growth and development. We aimed to determine the levels of DHA and EPA in cord serum after n-3 FA supplementation during the last trimester of pregnancy. Among 55 women, 23 were administered daily one capsule of n-3 FA supplement, involving DHA/EPA in a ratio of 1/1.3. Twenty nine women were enrolled as control group. Blood samples were collected at 22-24 weeks of gestation and at delivery. Fatty acids were analyzed with the method of GC-MS. Cord DHA level increased and EPA level decreased in both groups between the days of 22-24 and delivery. However, decrease in cord EPA level was significant in control group (p 0.05). Supplementation of DHA/EPA in a ratio of 1/1.3 during the last trimester of pregnancy caused higher cord EPA level compared to control group indicating an accumulation in umbilical cord. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Assessment of infiltration heat recovery and its impact on energy consumption for residential buildings

    International Nuclear Information System (INIS)

    Solupe, Mikel; Krarti, Moncef

    2014-01-01

    Highlights: • Five steady-state air infiltration heat recovery or IHR models are described and compared. • IHR models are incorporated within whole-building simulation analysis tool. • IHR can reduce the thermal loads of residential buildings by 5–30%. - Abstract: Infiltration is a major contributor to the energy consumption of buildings, particularly in homes where it accounts for one-third of the heating and cooling loads. Traditionally, infiltration is calculated independent of the building envelope performance, however, it has been established that a thermal coupling exists between the infiltration and conduction heat transfer of the building envelope. This effect is known as infiltration heat recovery (IHR). Experiments have shown that infiltration heat recovery can typically reduce the infiltration thermal load by 10–20%. Currently, whole-building energy simulation tools do not account for the effect of infiltration heat recovery on heating and cooling loads. In this paper, five steady-state IHR models are described to account for the thermal interaction between infiltration air and building envelope components. In particular, inter-model and experimental comparisons are carried out to assess the prediction accuracy of five IHR models. In addition, the results from a series of sensitivity analyses are presented, including an evaluation of the predictions for heating energy use associated with four audited homes obtained from whole-building energy simulation analysis with implemented infiltration heat recovery models. Experimental comparison of the IHR models reveal that the predictions from all the five models are consistent and are within 2% when 1-D flow and heat transfer conditions are considered. When implementing IHR models to a whole-building simulation environment, a reduction of 5–30% in heating consumption is found for four audited residential homes

  14. Air-to-air heat pumps in real-life use

    DEFF Research Database (Denmark)

    Gram-Hanssen, Kirsten; Christensen, Toke Haunstrup; Petersen, Poul Erik

    2012-01-01

    This paper deals with individual air-to-air heat pumps in Danish dwellings and summerhouses and the question of to what extent they actually deliver savings of energy consumption. Results show that 20% of the expected reduction of electricity consumption is converted into increased comfort...... in the homes, including extended heating areas, keeping a higher temperature and a longer heating season and using the heat pump for air conditioning. Data include electricity consumption in 185 households before and after installation of heat pumps together with survey results of 480 households. Furthermore...... heating practices. These results have to be taken into account when making long-term energy planning for a sustainable energy system....

  15. Induction Heating Process Design Using COMSOL Multiphysics Software

    Directory of Open Access Journals (Sweden)

    Andy Triwinarko

    2011-08-01

    Full Text Available Induction heating is clean environmental heating process due to a non-contact heating process. There is lots of the induction heating type that be used in the home appliance but it is still new technology in Indonesia. The main interesting area of the induction heating design is the efficiency of the usage of energy and choice of the plate material. COMSOL Multiphysics Software can be used to simulate and estimate the induction heating process. Therefore, the software can be used to design the induction heating process that will have a optimum efficiency. The properties of the induction heating design were also simulated and analyzed such as effect of inductors width, inductors distance, and conductive plate material. The result was shown that the good design of induction heating must have a short width and distance inductor and used silicon carbide as material plate with high frequency controller.

  16. Labeling and advertising of home insulation

    Energy Technology Data Exchange (ETDEWEB)

    1978-07-01

    This staff report, prepared by the F.T.C.'s Bureau of Consumer Protection for Commission review, includes recommendations as to the final form of a trade regulation rule relating to the labeling and advertising of home insulation. Because of marketing abuses which accompanied the rising demand for home insulation, there has been broad support for a rule requiring information disclosures to help purchasers of home insulation to make an informed decision. The Commission, to provide such rule as quickly as possible, undertook its rulemaking proceeding under its new expedited rulemaking procedure. The rule was proposed on November 18, 1977, and, following a two-month period for written comments, four weeks of hearings were held in Washington, D.C. in February 1978. The record, contributed to by a variety of interests, shows that consumers do not know how to shop for home insulation. The staff-recommended rule, among other things, would require that insulation be tested and R-values (a measure of insulation's ability to retain heat) disclosed on labels and in advertising. To facilitate comparison shopping, the industry would also be required to furnish consumers with fact sheets describing, on a product-to-product basis, factors that can reduce the R-value of insulation.

  17. 40 CFR 147.1703 - EPA-administered program-Indian lands.

    Science.gov (United States)

    2010-07-01

    ... Carolina § 147.1703 EPA-administered program—Indian lands. (a) Contents. The UIC program for all classes of wells on Indian lands in the State of North Carolina is administered by EPA. This program consists of... these requirements. (b) Effective date. The effective date of the UIC program for Indian lands in North...

  18. Feasibility of Achieving a Zero-Net-Energy, Zero-Net-Cost Homes

    Energy Technology Data Exchange (ETDEWEB)

    Al-Beaini, S.; Borgeson, S.; Coffery, B.; Gregory, D.; Konis, K.; Scown, C.; Simjanovic, J.; Stanley, J.; Strogen, B.; Walker, I.

    2009-09-01

    A green building competition, to be known as the Energy Free Home Challenge (EFHC), is scheduled to be opened to teams around the world in 2010. This competition will encourage both design innovation and cost reduction, by requiring design entries to meet 'zero net energy' and 'zero net cost' criteria. For the purposes of this competition, a 'zero net energy' home produces at least as much energy as it purchases over the course of a year, regardless of the time and form of the energy (e.g., electricity, heat, or fuel) consumed or produced. A 'zero net cost' home is no more expensive than a traditional home of comparable size and comfort, when evaluated over the course of a 30-year mortgage. In other words, the 'green premium' must have a payback period less than 30 years, based on the value of energy saved. The overarching goal of the competition is to develop affordable, high-performance homes that can be mass-produced at a large scale, and are able to meet occupant needs in harsh climates (as can be found where the competition will be held in Illinois). This report outlines the goals of the competition, and gauges their feasibility using both modeling results and published data. To ensure that the established rules are challenging, yet reasonable, this report seeks to refine the competition goals after exploring their feasibility through case studies, cost projections, and energy modeling. The authors of this report conducted a survey of the most progressive home energy-efficiency practices expected to appear in competition design submittals. In Appendix A, a summary can be found of recent projects throughout the United States, Canada, Germany, Switzerland, Sweden and Japan, where some of the most progressive technologies have been implemented. As with past energy efficient home projects, EFHC competitors will incorporate a multitude of energy efficiency measures into their home designs. The authors believe that

  19. EPA Region 1 - Map Layers for Valley ID Tool (Hosted Feature Service)

    Science.gov (United States)

    The Valley Service Feature Layer hosts spatial data for EPA Region 1's Valley Identification Tool. These layers contain attribute information added by EPA R1 GIS Center to help identify populated valleys:- Fac_2011NEI: Pollution sources selected from the National Emissions Inventory (EPA, 2011).- NE_Towns_PopValleys: New England Town polygons (courtesy USGS), with Population in Valleys and Population Density in Valleys calculated by EPA R1 GIS, from 2010 US Census blocks. - VT_E911: Vermont residences (courtesy VT Center for Geographic Information E-911).

  20. Wireless ZigBee home automation system

    Science.gov (United States)

    Craciunescu, Razvan; Halunga, Simona; Fratu, Octavian

    2015-02-01

    The home automation system concept existed for many years but in the last decade, due to the rapid development of sensors and wireless technologies, a large number of various such "intelligent homes" have been developed. The purpose of the present paper is to demonstrate the flexibility, reliability and affordability of home automation projects, based on a simple and affordable implementation. A wireless sensing and control system have been developed and tested, having a number of basic functionalities such as switching on/off the light according to ambient lighting and turning on/off the central heating. The system has been built around low power microcontrollers and ZigBee modems for wireless communication, using a set of Vishay 640 thermistor sensors for temperature measurements and Vishay LDR07 photo-resistor for humidity measurements. A trigger is activated when the temperature or light measurements are above/below a given threshold and a command is transmitted to the central unit through the ZigBee radio module. All the data processing is performed by a low power microcontroller both at the sensing device and at the control unit.

  1. BETTER DUCT SYSTEMS FOR HOME HEATING AND COOLING.

    Energy Technology Data Exchange (ETDEWEB)

    ANDREWS,J.

    2001-01-01

    This is a series of six guides intended to provide a working knowledge of residential heating and cooling duct systems, an understanding of the major issues concerning efficiency, comfort, health, and safety, and practical tips on installation and repair of duct systems. These guides are intended for use by contractors, system designers, advanced technicians, and other HVAC professionals. The first two guides are also intended to be accessible to the general reader.

  2. Solar Heating and Cooling of Residential Buildings: Sizing, Installation and Operation of Systems.

    Science.gov (United States)

    Colorado State Univ., Ft. Collins. Solar Energy Applications Lab.

    This training course and a companion course titled "Design of Systems for Solar Heating and Cooling of Residential Buildings," are designed to train home designers and builders in the fundamentals of solar hydronic and air systems for space heating and cooling and domestic hot water heating for residential buildings. Each course, organized in 22…

  3. 40 CFR 13.22 - Salary offset when EPA is the creditor agency.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Salary offset when EPA is the creditor... COLLECTION STANDARDS Administrative Offset § 13.22 Salary offset when EPA is the creditor agency. (a... through salary offset, EPA will first provide the employee with the opportunity to pay in full the amount...

  4. NaKnowBaseTM: The EPA Nanomaterials Research ...

    Science.gov (United States)

    The ability to predict the environmental and health implications of engineered nanomaterials is an important research priority due to the exponential rate at which nanotechnology is being incorporated into consumer, industrial and biomedical applications. To address this need and develop predictive capability, we have created the NaKnowbaseTM, which provides a platform for the curation and dissemination of EPA nanomaterials data to support functional assay development, hazard risk models and informatic analyses. To date, we have combined relevant physicochemical parameters from other organizations (e.g., OECD, NIST), with those requested for nanomaterial data submitted to EPA under the Toxic Substances Control Act (TSCA). Physiochemical characterization data were collated from >400 unique nanomaterials including metals, metal oxides, carbon-based and hybrid materials evaluated or synthesized by EPA researchers. We constructed parameter requirements and table structures for encoding research metadata, including experimental factors and measured response variables. As a proof of concept, we illustrate how SQL-based queries facilitate a range of interrogations including, for example, relationships between nanoparticle characteristics and environmental or toxicological endpoints. The views expressed in this poster are those of the authors and may not reflect U.S. EPA policy. The purpose of this submission for clearance is an abstract for submission to a scientific

  5. Survey of EPA facilities for solar thermal energy applications

    Science.gov (United States)

    Nelson, E. V.; Overly, P. T.; Bell, D. M.

    1980-01-01

    A study was done to assess the feasibility of applying solar thermal energy systems to EPA facilities. A survey was conducted to determine those EPA facilities where solar energy could best be used. These systems were optimized for each specific application and the system/facility combinations were ranked on the basis of greatest cost effectiveness.

  6. Abandoned Uranium Mines (AUM) Site Screening Map Service, 2016, US EPA Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — As described in detail in the Five-Year Report, US EPA completed on-the-ground screening of 521 abandoned uranium mine areas. US EPA and the Navajo EPA are using the...

  7. Advancing Replicable Solutions for High-Performance Homes in the Southeast

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, S. G. [Southface Energy Inst., Upper Marlboro, MD (United States); Sweet, M. L. [Southface Energy Inst., Upper Marlboro, MD (United States); Francisco, A. [Southface Energy Inst., Upper Marlboro, MD (United States)

    2016-03-01

    Southface Energy Institute (Southface) partnered with owners and/or builders with various market constraints and ultimate goals for three projects in different climate zones: Savannah, GA (CZ 2), Clemson, SC (CZ 3), and LaFayette, GA (CZ 4). This report documents the design process, computational energy modeling, construction, envelope performance metrics, long-term monitoring results, and successes and failures of the design and execution of these high performance homes. The three bedroom/two bathroom test home in Savannah Gardens on an elevated slab foundation has a semi-conditioned, encapsulated attic. A neighboring home built to EarthCraft specifications was also monitored as a control for exterior foam insulation and a heat pump water heater (HPWH). For the JMC Patrick Square, a single-story project in Clemson, the small-scale production builder wanted to increase their level of energy efficiency beyond their current green building practices, including bringing ducts into conditioned space. Through a combination of upgrade measures the team met this goal and achieved many Zero Energy Ready Home requirements. LaFayette Housing Authority undertook a development of 30 affordable rental housing units in 15 duplexes in LaFayette, GA. Because they would be long-term owners, their priorities were low utility bills for the residents and durable, maintainable buildings. The team employed BEopt to optimize buildling envelope and systems choices, including 2x6 advanced framed walls, insulated slab, and heat pump water heater in a utility closet which was ducted to/from an encapsulated attic.

  8. Local village heating. Final rapport; Landsby Naervarme. Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    Bojesen, C.

    2012-04-15

    Local Village Heating project relates to smaller villages which are located outside existing or planned district heating areas in Denmark. The analysis phase of Local Village Heating has shown that the concept can be the most feasible common heating system for villages that: 1. has a high building density - the buildings must be placed close together; 2. at least one large heat consumer, school, elder home or company is present in the village; 3. the number of buildings/households in the village is less than approx. 100. The analysis has shown that it is theoretical possible to establish a controlling system for the combined supplier/consumer option and an overall system for prioritizing the primary heat suppliers. A feasible Local Village Heating organisation could be a cooperative similar to other supply systems, such as common water supply and waste water cooperative. (Author)

  9. Documentation of Calculation Methodology, Input data, and Infrastructure for the Home Energy Saver Web Site

    Energy Technology Data Exchange (ETDEWEB)

    Pinckard, Margaret J.; Brown, Richard E.; Mills, Evan; Lutz, James D.; Moezzi, Mithra M.; Atkinson, Celina; Bolduc, Chris; Homan, Gregory K.; Coughlin, Katie

    2005-07-13

    The Home Energy Saver (HES, http://HomeEnergySaver.lbl.gov) is an interactive web site designed to help residential consumers make decisions about energy use in their homes. This report describes the underlying methods and data for estimating energy consumption. Using engineering models, the site estimates energy consumption for six major categories (end uses); heating, cooling, water heating, major appliances, lighting, and miscellaneous equipment. The approach taken by the Home Energy Saver is to provide users with initial results based on a minimum of user input, allowing progressively greater control in specifying the characteristics of the house and energy consuming appliances. Outputs include energy consumption (by fuel and end use), energy-related emissions (carbon dioxide), energy bills (total and by fuel and end use), and energy saving recommendations. Real-world electricity tariffs are used for many locations, making the bill estimates even more accurate. Where information about the house is not available from the user, default values are used based on end-use surveys and engineering studies. An extensive body of qualitative decision-support information augments the analytical results.

  10. Agriculture: About EPA's National Agriculture Center

    Science.gov (United States)

    EPA's National Agriculture Center (Ag Center), with the support of the United States Department of Agriculture, serves growers, livestock producers, other agribusinesses, and agricultural information/education providers.

  11. GET SMART: EPA'S SMARTE INITIATIVE

    Science.gov (United States)

    The EPA's Office of Research and Development with the assistance of the U.S.-German Bilateral Working Group and the Interstate Technology Regulatory Council (ITRC), is developing Site-specific Management Approaches and Revitalization Tools (SMART) that will help stakeholders over...

  12. EPA Principles for Greener Cleanups

    Science.gov (United States)

    A goal of the U.S. Environmental Protection Agency (EPA) Office and Land and Emergency Management (OLEM) and its many partners is to preserve and restore land by promoting and using protective waste management practices and by assessing and cleaning..

  13. USDA-EPA Collaborative Ammonia Research

    Science.gov (United States)

    In 2014, a work group was formed between USDA and EPA to facilitate information exchange on ammonia emissions from agriculture, air quality impacts and emission mitigation options and to identify opportunities for collaboration. This document provides background on the work grou...

  14. US EPA Digital Science: An Evolution

    Science.gov (United States)

    Ziegler, C. R.; Burch, K.; Laniak, G.; Vega, A.; Harten, P.; Kremer, J.; Brookes, A.; Yuen, A.; Subramanian, B.

    2015-12-01

    The United States Environmental Protection Agency's (US EPA) digital science "enterprise" plays a critical role in US EPA's efforts to achieve its mission to protect human health and the environment. This enterprise is an evolving cross-disciplinary research and development construct, with social and institutional dimensions. It has an active development community and produces a portfolio of digital science products including decision support tools, data repositories, Web interfaces, and more. Earth sciences and sustainable development organizations from around the world - including US government agencies - have achieved various levels of success in taking advantage of the rapidly-evolving digital age. Efficiency, transparency and ability to innovate are tied to an organization's digital maturity and related social characteristics. Concepts like participatory web, data and software interoperability, global technology transfer, ontological harmonization, big data, scaling, re-use and open science are no longer "new and emerging." They have emerged and - in some cases - are tied to US government directives. We assess maturity, describe future scenarios, discuss new initiatives and outline steps for better leveraging the information age to more effectively and efficiently achieve US EPA's mission. The views expressed herein are those of the authors and do not necessarily reflect the views or policies of the organizations for which they work and/or represent.

  15. Efficient Solutions for New Homes Case Study: Savannah Gardens

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-03-15

    The Savannah Housing Department is leading sustainable and affordable housing development in Georgia. It partnered with Southface Energy Institute, a member of the U.S. Department of Energy’s Partnership for Home Innovation Building America research team, to seek cost-effective solutions for increasing the energy efficiency of the Savannah Housing Department’s standard single-family home plans in the Savannah Gardens Community. Based on engineering, cost, and constructability analyses, the combined research team chose to pilot two technologies to evaluate efficiency and comfort impacts for homeowners: a heat-pump water heater in an encapsulated attic and an insulated exterior wall sheathing.

  16. Wood energy for residential heating in Alaska: current conditions, attitudes, and expected use

    Science.gov (United States)

    David L. Nicholls; Allen M. Brackley; Valerie. Barber

    2010-01-01

    This study considered three aspects of residential wood energy use in Alaska: current conditions and fuel consumption, knowledge and attitudes, and future use and conditions. We found that heating oil was the primary fuel for home heating in southeast and interior Alaska, whereas natural gas was used most often in south-central Alaska (Anchorage). Firewood heating...

  17. EPA RE-Powering Mapper Region 7

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  18. EPA RE-Powering Mapper Large Scale

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  19. EPA RE-Powering Mapper Region 6

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  20. EPA RE-Powering Mapper Region 8

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  1. EPA RE-Powering Mapper Region 5

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  2. EPA RE-Powering Mapper Region 3

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  3. EPA RE-Powering Mapper Feasibility Studies

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  4. EPA RE-Powering Mapper Completed Installations

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  5. EPA RE-Powering Mapper Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  6. EPA RE-Powering Mapper Region 10

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  7. EPA RE-Powering Mapper Region 4

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  8. EPA RE-Powering Mapper Utility Scale

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  9. EPA RE-Powering Mapper Region 2

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  10. EPA RE-Powering Mapper Region 1

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  11. EPA Facility Registry Service (FRS): RCRA

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of hazardous waste...

  12. EPA-Registered Repellents for Mosquitoes Transmitting Emerging Viral Disease.

    Science.gov (United States)

    Patel, Radha V; Shaeer, Kristy M; Patel, Pooja; Garmaza, Aleksey; Wiangkham, Kornwalee; Franks, Rachel B; Pane, Olivia; Carris, Nicholas W

    2016-12-01

    In many parts of the United States, mosquitoes were previously nuisance pests. However, they now represent a potential threat in the spread of viral diseases. The Aedes aegypti, Aedes albopictus, and Culex species mosquitoes are endemic to the United States and together may transmit a variety of viral diseases of growing concern, including West Nile virus, chikungunya, dengue fever, and Zika virus. The Centers for Disease Control and Prevention and the Environmental Protection Agency (EPA) recommend N,N-diethyl-meta-toluamide (DEET) as a first-line mosquito repellent, but for patients refusing to use DEET or other conventional repellents, guidance is limited to any EPA-registered product. Therefore, we conducted a systematic review of the literature to identify which EPA-registered personal mosquito repellent provides the best protection from A. aegypti, A. albopictus, and Culex spp. mosquitoes. We abstracted data from 62 published reports of EPA-registered mosquito repellents. The conventional repellent picaridin has the strongest data to support its use as a second-line agent, while IR3535 and oil of lemon eucalyptus are reasonably effective natural products. Citronella, catnip, and 2-undecanone offer limited protection or have limited data. These results can be used by pharmacists and other health care professionals to advise patients on the selection of an EPA-registered mosquito repellent. Regardless of the repellent chosen, it is vital for patients to follow all instructions/precautions in the product labeling to ensure safe and effective use. © 2016 Pharmacotherapy Publications, Inc.

  13. Effect of surface etching on condensing heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Seok, Sung Chul; Park, Jae Won; Jung, Jiyeon; Choi, Chonggun; Choi, Gyu Hong; Hwang, Seung Sik; Chung, Tae Yong; Shin, Donghoon [Kookmin University, Seoul (Korea, Republic of); Kim, Jin Jun [Hoseo University, Asan (Korea, Republic of)

    2016-02-15

    This study conducted experiments on humid air condensation during heat transfer in an air preheating exchanger attached to a home condensing boiler to improve thermal efficiency. An etchant composed of sulfuric acid and sodium nitrate was used to create roughness on the heat exchanger surface made from STS430J1L. A counter flow heat exchanger was fabricated to test the performance of heat transfer. Results showed that the overall heat transfer coefficients of all specimens treated with etchant improved with respect to the original specimens (not treated with etchant), and the overall heat transfer coefficient of the 60 s etching specimen increased by up to 15%. However, the increasing rate of the heat transfer coefficient was disproportional to the etching time. When the etching time specifically increased above 60 s, the heat transfer coefficient decreased. This effect was assumed to be caused by surface characteristics such as contact angle. Furthermore, a smaller contact angle or higher hydrophilicity leads to higher heat transfer coefficient.

  14. Development of an Air-Source Heat Pump Integrated with a Water Heating / Dehumidification Module

    Energy Technology Data Exchange (ETDEWEB)

    Rice, C Keith [ORNL; Uselton, Robert B. [Lennox Industries, Inc; Shen, Bo [ORNL; Baxter, Van D [ORNL; Shrestha, Som S [ORNL

    2014-01-01

    A residential-sized dual air-source integrated heat pump (AS-IHP) concept is under development in partnership between ORNL and a manufacturer. The concept design consists of a two-stage air-source heat pump (ASHP) coupled on the air distribution side with a separate novel water heating/dehumidification (WH/DH) module. The motivation for this unusual equipment combination is the forecast trend for home sensible loads to be reduced more than latent loads. Integration of water heating with a space dehumidification cycle addresses humidity control while performing double-duty. This approach can be applied to retrofit/upgrade applications as well as new construction. A WH/DH module capable of ~1.47 L/h water removal and ~2 kW water heating capacity was assembled by the manufacturer. A heat pump system model was used to guide the controls design; lab testing was conducted and used to calibrate the models. Performance maps were generated and used in a TRNSYS sub-hourly simulation to predict annual performance in a well-insulated house. Annual HVAC/WH energy savings of ~35% are predicted in cold and hot-humid U.S. climates compared to a minimum efficiency baseline.

  15. EPA's Benchmark Dose Modeling Software

    Science.gov (United States)

    The EPA developed the Benchmark Dose Software (BMDS) as a tool to help Agency risk assessors facilitate applying benchmark dose (BMD) method’s to EPA’s human health risk assessment (HHRA) documents. The application of BMD methods overcomes many well know limitations ...

  16. EPA Facility Registry Service (FRS): NCDB

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  17. EPA Facility Registry Service (FRS): BRAC

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  18. EPA Facility Registry Service (FRS): BIA

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  19. EPA Facility Registry Service (FRS): RADINFO

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  20. EPA Facility Registry Service (FRS): TRI

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  1. EPA Facility Registry Service (FRS): ICIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  2. EPA Facility Registry Service (FRS): RBLC

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  3. EPA Facility Registry System (FRS): NCES

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  4. EPA Facility Registry Service (FRS): LANDFILL

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of non-hazardous waste...

  5. EPA Facility Registry Service (FRS): NEI

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  6. EPA Facility Registry Service (FRS): CAMDBS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  7. EPA Facility Registry System (FRS): NEPT

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  8. EPA Facility Registry Service (FRS): SDWIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  9. EPA Facility Registry Service (FRS): RMP

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  10. Green Roof Research through EPA's Regional Applied Research Effort - slides

    Science.gov (United States)

    The U.S. Environmental Protection Agency’s (EPA) Regional Applied Research Effort (RARE) allows the Regions of the EPA to choose research projects to be performed in partnership with EPA’s Office of Research and Development (ORD). Over the last decade, several green roof projects...

  11. 40 CFR 70.8 - Permit review by EPA and affected States.

    Science.gov (United States)

    2010-07-01

    ... compatible with EPA's national database management system. (2) The Administrator may waive the requirements... PROGRAMS (CONTINUED) STATE OPERATING PERMIT PROGRAMS § 70.8 Permit review by EPA and affected States. (a...

  12. From Energy Audits to Home Performance: 30 Years of Articles in Home Energy Magazine

    Energy Technology Data Exchange (ETDEWEB)

    Meier, Alan

    2014-08-11

    Home Energy Magazine has been publishing articles about residential energy efficiency for 30 years. Its goal has been to disseminate technically reliable and neutral information to the practitioners, that is, professionals in the business of home energy efficiency. The articles, editorials, letters, and advertisements are a kind of window on the evolution of energy conservation technologies, policies, and organizations. Initially, the focus was on audits and simple retrofits, such as weatherstripping and insulation. Instrumentation was sparse sometimes limited to a ruler to measure depth of attic insulation and a blower door was exotic. CFLs were heavy, awkward bulbs which might, or might not, fit in a fixture. Saving air conditioning energy was not a priority. Solar energy was only for the most adventurous. Thirty years on, the technologies and business have moved beyond just insulating attics to the larger challenge of delivering home performance and achieving zero net energy. This shift reflects the success in reducing space heating energy and the need to create a profitable industry by providing more services. The leading edge of the residential energy services market is becoming much more sophisticated, offering both efficiency and solar systems. The challenge is to continue providing relevant and reliable information in a transformed industry and a revolutionized media landscape.

  13. EPA Pacific Southwest Enforcement Division Inspected Tax Map Key Polygons, Hawaii, 2017, US EPA Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — This feature class contains the 64 tax map key polygons across the state of Hawaii that have been inspected by US EPA Pacific Southwest Enforcement Division as of...

  14. EPA/DOE joint efforts on mixed waste treatment

    International Nuclear Information System (INIS)

    Lee, C.C.; Huffman, G.L.; Nalesnik, R.P.

    1995-01-01

    Under the requirements of the Federal Facility Compliance Act (FFCA), the Department of Energy (DOE) is directed to develop treatment plans for their stockpile of wastes generated at their various sites. As a result, DOE is facing the monumental problem associated with the treatment and ultimate disposal of their mixed (radioactive and hazardous) waste. Meanwhile, the Environmental Protection Agency (EPA) issued a final open-quotes Hazardous Waste Combustion Strategyclose quotes in November 1994. Under the Combustion Strategy, EPA permit writers have been given the authority to use the Omnibus Provision of the Resource Conservation and Recovery Act (RCRA) to impose more stringent emission limits for waste combustors prior to the development of new regulations. EPA and DOE established a multi-year Interagency Agreement (IAG) in 1991. The main objective of the IAG (and of the second IAG that was added in 1993) is to conduct a research program on thermal technologies for treating mixed waste and to establish permit procedures for these technologies particularly under the new requirements of the above-mentioned EPA Combustion Strategy. The objective of this Paper is to summarize the results of the EPA/DOE joint efforts on mixed waste treatment since the establishment of the original Interagency Agreement. Specifically, this Paper will discuss six activities that have been underway; namely: (1) National Technical Workgroup (NTW) on Mixed Waste Treatment, (2) State-of-the-Art Assessment of APC (Air Pollution Control) and Monitoring Technologies for the Rocky Flats Fluidized Bed Unit, (3) Initial Study of Permit open-quotes Roadmapclose quotes Development for Mixed Waste Treatment, (4) Risk Assessment Approach for a Mixed Waste Thermal Treatment Facility, (5) Development and Application of Technology Selection Criteria for Mixed Waste Thermal Treatment, and (6) Performance Testing of Mixed Waste Incineration: In-Situ Chlorine Capture in a Fluidized Bed Unit

  15. Michigan residential No. 2 fuel oil and propane price survey for the 1990/91 heating season

    International Nuclear Information System (INIS)

    1991-10-01

    This report summarizes the results of a survey of home heating oil and propane prices over the 1990/1991 heating season in Michigan. The survey was conducted under a cooperative agreement between the State of Michigan, Michigan Public Service Commission and the US Department of Energy (DOE), Energy Information Administration (EIA), and was funded by a grant from EIA. From October 1990 through May 1991, participating dealers/distributions were called and asked for their current residential retail prices of No. 2 home heating oil and propane. This information was then transmitted to the EIA, bi-monthly using an electronic reporting system called Petroleum Data Reporting Option (PEDRO). The survey was conducted using a sample provided by EIA of home heating oil and propane retailers which supply Michigan households. These retailers were contacted the first and third Mondays of each month. The sample was designed to account for distributors with different sales volumes, geographic distributions and sources of primary supply. It should be noted that this simple is different from the sample used in prior year surveys

  16. Concerns raised over new EPA members

    Science.gov (United States)

    Gwynne, Peter

    2017-12-01

    The Trump administration has nominated three new members of the Environmental Protection Agency (EPA) who critics say are undermining laws and “pampering” the industries they are supposed to regulate.

  17. EPA Facility Registry Service (FRS): OIL

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link to the Oil...

  18. Demonstration of Hydrogen Energy Network and Fuel Cells in Residential Homes

    International Nuclear Information System (INIS)

    Hirohisa Aki; Tetsuhiko Maeda; Itaru Tamura; Akeshi Kegasa; Yoshiro Ishikawa; Ichiro Sugimoto; Itaru Ishii

    2006-01-01

    The authors proposed the setting up of an energy interchange system by establishing energy networks of electricity, hot water, and hydrogen in residential homes. In such networks, some homes are equipped with fuel cell stacks, fuel processors, hydrogen storage devices, and large storage tanks for hot water. The energy network enables the flexible operation of the fuel cell stacks and fuel processors. A demonstration project has been planned in existing residential homes to evaluate the proposal. The demonstration will be presented in a small apartment building. The building will be renovated and will be equipped with a hydrogen production facility, a hydrogen interchange pipe, and fuel cell stacks with a heat recovery device. The energy flow process from hydrogen production to consumption in the homes will be demonstrated. This paper presents the proposed energy interchange system and demonstration project. (authors)

  19. Hispanos en la EPA: Neftalí Hernández-Santiago

    Science.gov (United States)

    La diversidad de la fuerza laboral es importante para la Agencia de Protección Ambiental de EE.UU. (EPA, por sus siglas en inglés). Los empleados hispanos de la EPA contribuyen diariamente hacia la protección de la salud y el medio ambiente.

  20. 78 FR 13872 - Proposed Information Collection Request; Comment Request; EPA's WaterSense Program (Renewal); EPA...

    Science.gov (United States)

    2013-03-01

    ... profanity, threats, information claimed to be Confidential Business Information (CBI) or other information...-efficient products and use water-efficient practices. As part of strategic planning efforts, EPA encourages... Reporting Form Promotional partners 6100-09 Manufacturers (separate forms for plumbing and non- plumbing...

  1. Modelling the formation of heat-induced contaminants during thermal processing of food

    NARCIS (Netherlands)

    Nguyen, H.T.

    2015-01-01

    Many of our food products have undergone a heat-treatment before consumption, either at home or at the food industry. Heat treatments not only bring out desired characteristics of the food products such as flavour, texture, taste and safety aspects but also leads to the formation of undesired

  2. Technical Feasibility Study for Deployment of Ground-Source Heat Pump Systems: Portsmouth Naval Shipyard -- Kittery, Maine

    Energy Technology Data Exchange (ETDEWEB)

    Hillesheim, M.; Mosey, G.

    2014-11-01

    The U.S. Environmental Protection Agency (EPA) Office of Solid Waste and Emergency Response, in accordance with the RE-Powering America's Lands initiative, engaged the U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to conduct feasibility studies to assess the viability of developing renewable energy generating facilities on contaminated sites. Portsmouth Naval Shipyard (PNSY) is a United States Navy facility located on a series of conjoined islands in the Piscataqua River between Kittery, ME and Portsmouth, NH. EPA engaged NREL to conduct a study to determine technical feasibility of deploying ground-source heat pump systems to help PNSY achieve energy reduction goals.

  3. DOE ZERH Case Study: TC Legend Homes, Bellingham Power House, Bellingham, WA

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2015-09-01

    Case study of a DOE 2015 Housing Innovation Award winning custom home in the marine climate that got HERS 34 without PV or HERS -12 with PV, with 6” SIP walls and 10” SIP roof; R-28 ICF around slab, R-20 rigid foam under slab; radiant floor heat and passive design; air-to-water heat pump COP 4.4; HRV; earth tube ventilation; triple-pane windows, 100% LED.

  4. Residents' Coping Strategies in an Extended-Stay Hotel Home

    Science.gov (United States)

    Lewinson, Terri

    2010-01-01

    Some families live in extended-stay hotels as a solution after housing displacement. This temporary accommodation provides a furnished home environment with resources such as a kitchenette, bed, heating/air conditioning, and room services with one payment that can be made weekly or monthly without a credit check or rent deposit. Despite these…

  5. EPA Center for Corporate Climate Leadership

    Science.gov (United States)

    EPA's Center for Corporate Climate Leadership is a comprehensive resource to help organizations measure & manage GHG emissions. The Center provides technical tools, educational resources, opportunities for information sharing & highlights best practices.

  6. EPA CIO Governance Board Membership List

    Science.gov (United States)

    In keeping with OMB guidance on implementing the Federal Information Technology Reform Act (FITARA), EPA is publishing its list of officials who perform the duties or responsibilities of a Bureau CIO.

  7. EPA Administrative Law Judge Legal Documents

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains Decisions and Orders originating from EPAs Office of Administrative Law Judges (OALJ), which is an independent office in the Office of the...

  8. 2013 EPA Vessels General Permit (VGP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Information for any vessel that submitted a Notice of Intent (NOI), Notice of Termination (NOT), or annual report under EPA's 2013 Vessel General Permit (VGP)....

  9. EPA Facility Registry Service (FRS): ACRES

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service consists of location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of sites that link to...

  10. Home safe home: Evaluation of a childhood home safety program.

    Science.gov (United States)

    Stewart, Tanya Charyk; Clark, Andrew; Gilliland, Jason; Miller, Michael R; Edwards, Jane; Haidar, Tania; Batey, Brandon; Vogt, Kelly N; Parry, Neil G; Fraser, Douglas D; Merritt, Neil

    2016-09-01

    The London Health Sciences Centre Home Safety Program (HSP) provides safety devices, education, a safety video, and home safety checklist to all first-time parents for the reduction of childhood home injuries. The objective of this study was to evaluate the HSP for the prevention of home injuries in children up to 2 years of age. A program evaluation was performed with follow-up survey, along with an interrupted time series analysis of emergency department (ED) visits for home injuries 5 years before (2007-2013) and 2 years after (2013-2015) implementation. Spatial analysis of ED visits was undertaken to assess differences in home injury rates by dissemination areas controlling differences in socioeconomic status (i.e., income, education, and lone-parent status) at the neighborhood level. A total of 3,458 first-time parents participated in the HSP (a 74% compliance rate). Of these, 20% (n = 696) of parents responded to our questionnaire, with 94% reporting the program to be useful (median, 6; interquartile range, 2 on a 7-point Likert scale) and 81% learning new strategies for preventing home injuries. The median age of the respondent's babies were 12 months (interquartile range, 1). The home safety check list was used by 87% of respondents to identify hazards in their home, with 95% taking action to minimize the risk. The time series analysis demonstrated a significant decline in ED visits for home injuries in toddlers younger than2 years of age after HSP implementation. The declines in ED visits for home injuries remained significant over and above each socioeconomic status covariate. Removing hazards, supervision, and installing safety devices are key facilitators in the reduction of home injuries. Parents found the HSP useful to identify hazards, learn new strategies, build confidence, and provide safety products. Initial finding suggests that the program is effective in reducing home injuries in children up to 2 years of age. Therapeutic/care management study

  11. Evaluation of mercury speciation by EPA (Draft) Method 29

    Energy Technology Data Exchange (ETDEWEB)

    Laudal, D.L.; Heidt, M.K. [Energy & Environmental Research Center, Grand Forks, ND (United States); Nott, B. [Electric Power Research Institute, Palo Alto, CA (United States)

    1995-11-01

    The 1990 Clean Air Act Amendments require that the U.S. Environmental protection Agency (EPA) assess the health risks associated with mercury emissions. Also, the law requires a separate assessment of health risks posed by the emission of 189 tract chemicals (including mercury) for electric utility steam-generating units. In order to conduct a meaningful assessment of health and environmental effects, we must have, among other things, a reliable and accurate method to measure mercury emissions. In addition, the rate of mercury deposition and the type of control strategies used may depend upon the type of mercury emitted (i.e., whether it is in the oxidized or elemental form). It has been speculated that EPA (Draft) Method 29 can speciate mercury by selective absorption; however, this claim has yet to be proven. The Electric Power Research Institute (EPRI) and the U.S. Department of Energy (DOE) have contracted with the Energy & Environmental Research Center (EERC) at University of North Dakota to evaluate EPA (Draft) Method 29 at the pilot-scale level. The objective of the work is to determine whether EPA (Draft) Method 29 can reliably quantify and speciate mercury in the flue gas from coal-fired boilers.

  12. Scenario sensitivity analyses performed on the PRESTO-EPA LLW risk assessment models

    International Nuclear Information System (INIS)

    Bandrowski, M.S.

    1988-01-01

    The US Environmental Protection Agency (EPA) is currently developing standards for the land disposal of low-level radioactive waste. As part of the standard development, EPA has performed risk assessments using the PRESTO-EPA codes. A program of sensitivity analysis was conducted on the PRESTO-EPA codes, consisting of single parameter sensitivity analysis and scenario sensitivity analysis. The results of the single parameter sensitivity analysis were discussed at the 1987 DOE LLW Management Conference. Specific scenario sensitivity analyses have been completed and evaluated. Scenario assumptions that were analyzed include: site location, disposal method, form of waste, waste volume, analysis time horizon, critical radionuclides, use of buffer zones, and global health effects

  13. 48 CFR 1552.223-71 - EPA Green Meetings and Conferences.

    Science.gov (United States)

    2010-10-01

    ... provision or language substantially the same as the provision in solicitations for meetings and conference services. EPA Green Meetings and Conferences (MAY 2007) (a) The mission of the EPA is to protect human... information about environmentally preferable features and practices your facility will have in place for the...

  14. EPA Region 6 REAP Composite Geodatabse

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Regional Ecological Assessment Protocol (REAP) is a screening level tool created as a way to identify priority ecological resources within the five EPA Region 6...

  15. Meet EPA Researcher Endalkachew Sahle-Demessie

    Science.gov (United States)

    Meet EPA Researcher Endalkachew Sahle-Demessie. Chemical and Environmental Engineer Endalkachew Sahle-Demessie, Ph.D., works on various projects, including nanomaterials and water resources, in EPA’s National Risk Management Research Laboratory.

  16. EPA Region 1 Sole Source Aquifers

    Data.gov (United States)

    U.S. Environmental Protection Agency — This coverage contains boundaries of EPA-approved sole source aquifers. Sole source aquifers are defined as an aquifer designated as the sole or principal source of...

  17. EPA Region 6 REAP Diversity Geodatabase

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Regional Ecological Assessment Protocol (REAP) is a screening level tool created as a way to identify priority ecological resources within the five EPA Region 6...

  18. Electrostatic Plasma Accelerator (EPA)

    Science.gov (United States)

    Brophy, John R.; Aston, Graeme

    1995-01-01

    The application of electric propulsion to communications satellites, however, has been limited to the use of hydrazine thrusters with electric heaters for thrust and specific impulse augmentation. These electrothermal thrusters operate at specific impulse levels of approximately 300 s with heater powers of about 500 W. Low power arcjets (1-3 kW) are currently being investigated as a way to increase specific impulse levels to approximately 500 s. Ion propulsion systems can easily produce specific impulses of 3000 s or greater, but have yet to be applied to communications satellites. The reasons most often given for not using ion propulsion systems are their high level of overall complexity, low thrust with long burn times, and the difficulty of integrating the propulsion system into existing commercial spacecraft busses. The Electrostatic Plasma Accelerator (EPA) is a thruster concept which promises specific impulse levels between low power arcjets and those of the ion engine while retaining the relative simplicity of the arcjet. The EPA thruster produces thrust through the electrostatic acceleration of a moderately dense plasma. No accelerating electrodes are used and the specific impulse is a direct function of the applied discharge voltage and the propellant atomic mass.

  19. Comments on EPA's LLW preproposal

    International Nuclear Information System (INIS)

    Littleton, B.K.; Weinstock, L.

    1995-01-01

    The Environmental Protection Agency (EPA) is currently developing standards for the management, storage, and disposal of Low-Level Radioactive Waste (LLW). The Atomic Energy Act delegated EPA, among other provisions, the authority to establish generally applicable standards for the disposal of radioactive waste to ensure that the public and the environment are adequately protected from potential radiation impacts. As an initial effort to open communications on a standard for LLW, the Agency developed a preproposal draft (Preproposal Draft of 40 CFR Part 193 - 30 Nov 94) and circulated it to interested parties for review and comment. The extended comment period ended April 12, 1995. A summary of the comments received and analyzed to date follows. After all comments have been analyzed, the rule will undergo an Agency clearance process and be sent to the Office of Management and Budget for review. After that review, the formal process of publication of the proposed rule in the Federal Register and the formal public comment period will begin

  20. Existing Whole-House Solutions Case Study: Greenbelt Homes, Inc. Pilot Retrofit Project

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-06-01

    In the fall of 2010, a multiyear pilot energy efficiency retrofit project was undertaken by Greenbelt Homes, Inc., (GHI) a 1,566 home cooperative of circa 1930 and 1940 homes in Greenbelt, Maryland. GHI established this pilot project to serve as a basis for decision making for the rollout of a community-wide upgrade program that will incorporate energy efficiency improvements to the building envelope and mechanical equipment. With the community upgrade fully funded by the cooperative through their membership without outside subsidies, this project presents a unique opportunity to evaluate and prioritize the wide range of benefits of high-performance retrofits based on member experience with and acceptance of the retrofit measures implemented during the pilot project. Addressing the complex interactions between benefits, trade-offs, construction methods, project management implications, realistic upfront costs, financing, and other considerations, serves as a case study for energy retrofit projects that include high-performance technologies based on the long-term value to the homeowner. The pilot project focused on identifying the added costs and energy-savings benefits of improvements. Phase 1—baseline evaluation for a representative set of 28 homes sited in seven buildings; Phase 2—installation of the building envelope improvements and continued monitoring of the energy consumption for the heating season; Phase 3—energy simulations supporting recommendations for HVAC and water heating upgrades.

  1. Effects of home-made boiling of bovine raw milk on its microbiological quality

    Directory of Open Access Journals (Sweden)

    Giampaolo Colavita

    2012-10-01

    Full Text Available The consumption of raw milk in Italy is allowed only “after boiling”. The aim of this research was to bet-ter understand how the heat treatment of raw milk performed at home by consumers assures their mi-crobiological safety. 50 samples of raw milk (each sample 500 ml provided to consumers who regularly buy raw milk from self-service automatic vending machines were followed from delivery till to after do-mestic heat treatment. Heating was performed by consumers according to their habits. The 50 samples were exposed to different heat treatments of which the mildest was at 68.5 °C and the most intense was at 97.8 °C before switching off. The average of temperatures used was 89.5 °C and the mode was 93.2 °C. According to the different parameters of heat treatment observed, 35 samples of raw milk and 35 samples of heated milk were selected for microbiological and process indicator analyses. Total Microbial Count (TMC, total and fecal coliforms, Escherichia coli, Staphylococcus aureus and Bacillus cereus loads were determined. E. coli was isolated only from one sample of raw milk. No B. cereus nor S. aure-us were found in all samples. After heat treatment, 4 samples showed a residual TMC ranging between 1,7 CFU/ml and 3,2 CFU/ml, whilst the count of total and fecal coliforms were irrelevant. The test for alkaline phosphatase has showed negative in all samples of heated milk, while the test of lactoperoxi-dase was positive in 3 samples. Results indicated that the microbiological risk attributable to the consumption of home heated raw milk is low, if the consumer applies regularly a good heating process.

  2. Air pollution prevention through urban heat island mitigation: An update on the urban heat island pilot project

    Energy Technology Data Exchange (ETDEWEB)

    Gorsevski, V.; Taha, H.; Quattrochi, D.; Luvall, J.

    1998-07-01

    Urban heat islands increase the demand for cooling energy and accelerate the formation of smog. They are created when natural vegetation is replaced by heat-absorbing surfaces such as building roofs and walls, parking lots, and streets. Through the implementation of measures designed to mitigate the urban heat island, communities can decrease their demand for energy and effectively cool the metropolitan landscape. In addition to the economic benefits, using less energy leads to reductions in emission of CO{sub 2}--a greenhouse gas--as well as ozone (smog) precursors such as NOx and VOCs. Because ozone is created when NOx and VOCs photochemically combine with heat and solar radiation, actions taken to lower ambient air temperature can significantly reduce ozone concentrations in certain areas. Measures to reverse the urban heat island include afforestation and the widespread use of highly reflective surfaces. To demonstrate the potential benefits of implementing these measures, EPA has teamed up with NASA and LBNL to initiate a pilot project with three US cities. As part of the pilot, NASA will use remotely-sensed data to quantify surface temperature, albedo, the thermal response number and NDVI vegetation of each city. This information will be used by scientists at Lawrence Berkeley National Laboratory (LBNL) along with other data as inputs to model various scenarios that will help quantify the potential benefits of urban heat island mitigation measures in terms of reduced energy use and pollution. This paper will briefly describe this pilot project and provide an update on the progress to date.

  3. Environmental Protection Agency - EPA Pub Central

    Data.gov (United States)

    U.S. Environmental Protection Agency — PubMed Central (PMC) is a full-text, online archive of journal literature operated by the National Library of Medicine. The EPA is using PMC to permanently preserve...

  4. Intelligent Heat System - High-Energy Efficient Wood Stoves with Low Emissions. Field Tests

    DEFF Research Database (Denmark)

    Illerup, Jytte Boll; Nickelsen, Joachim; Hansen, Brian Brun

    2014-01-01

    Wood stoves have the potential of providing CO2-neutral energy without transmission loss—but with the significant drawbacks of high emissions of pollutants and particulate matter at low altitude close to private homes, and with an uneven heat release profile which produces non-optimal heating...

  5. 40 CFR 131.22 - EPA promulgation of water quality standards.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false EPA promulgation of water quality... PROGRAMS WATER QUALITY STANDARDS Procedures for Review and Revision of Water Quality Standards § 131.22 EPA promulgation of water quality standards. (a) If the State does not adopt the changes specified by the Regional...

  6. 76 FR 27315 - EPA Science Advisory Board Staff Invitation to a Session on Public Involvement in EPA Advisory...

    Science.gov (United States)

    2011-05-11

    ... and SAB Three inter-related public access Web sites ( http://www.epa.gov/advisorycouncilcaa , http...) ``Recent Happenings'' and ``Recent Additions'' sections and related ``really simple syndication'' (RSS...

  7. Design of advanced solar homes aimed at net-zero annual energy consumption in Canada

    Energy Technology Data Exchange (ETDEWEB)

    Athienitis, Andreas

    2010-09-15

    This paper overviews the design of three sustainable low or net-zero energy solar homes in Canada. The major features of the houses are: 1. direct gain passive solar design that emphasizes utilization of distributed thermal mass in the equatorial-facing part of the ground floor; 2. a building-integrated photovoltaic-thermal system (BIPV/T); 3. a two-stage ground-source heat pump used to heat/cool air in the house or an air source heat pump using BIPV/T air as the source to heat a storage tank; 4. a floor heating system integrated in the floor mass of the direct gain zone; 5. a multizone programmable thermostat.

  8. Regulatory decision with EPA/NRC/DOE/State Session (Panel)

    Energy Technology Data Exchange (ETDEWEB)

    O`Donnell, E.

    1995-12-31

    This panel will cover the Nuclear Regulatory Commission`s (NRC) proposed radiation limits in the Branch Technical Position on Low-Level Radioactive Waste Performance Assessment and the Environmental Protection Agency`s (EPA) draft regulation in Part 193. Representatives from NRC and EPA will discuss the inconsistencies in these two regulations. DOE and state representatives will discuss their perspective on how these regulations will affect low-level radioactive waste performance assessments.

  9. EPA's analytical methods for water: The next generation

    International Nuclear Information System (INIS)

    Hites, R.A.; Budde, W.L.

    1991-01-01

    By the late 1970s, it had become clear to EPA that organic compounds were polluting many of the nation's waters. By 1977, as a result of a lawsuit by several environmentally concerned plaintiffs, EPA had focused on a list of 114 'priority' organic pollutants. Its long-term goal was the regulation of specific compounds that were found to pose significant environmental problems, a daunting task. Tens of thousands of samples needed to be measured by hundreds of different laboratories. Clearly, there were concerns about the comparability of data among laboratories. The result was a series of laboratory-based analytical 'methods.' These EPA methods are detailed, step-by-step directions (recipes) that describe everything the analyst needs to know to complete a satisfactory analysis. During the 1970s the first set of methods was developed; this was the '600 series' for the analysis of organic compounds in wastewater. In 1979 and the 1980s, a set of '500 series' methods, focusing on drinking water, was developed. By now, many of the 500 and 600 series methods are in widespread use, and it is clear that there are considerably overlaps among the methods in terms of both procedures and analytes. Indiana University was asked by EPA to consider the question, 'Is it possible to revise or eliminate some of the 500 and 600 series methods and effect a savings of time and money?' This and related questions were studied and recommendations were developed

  10. Energy Management strategies for Smart Home Regarding Uncertainties: State of the art, Trends, and Challenges

    DEFF Research Database (Denmark)

    Yousefi, Mojtaba; Hajizadeh, Amin; N. Soltani, Mohsen

    2018-01-01

    The advent of Smart grid and high-energy demand for electricity has provided new opportunities for energy management systems (EMSs) in a smart home (SH). Energy management strategies play a key role in performance and economy of smart homes integrating renewable energy resources, Heat Pumps (HP......), and Plug-in Electrical Vehicle (PEV) energy storages. This paper presents a critical review and analysis of different energy management strategies for SH to handle the uncertainties involved in renewable energy resources, home load demands, PEV charging requirements, and household comfort. In addition...

  11. 77 FR 46089 - Agency Information Collection Activities; Proposed Collection; Comment Request; EPA's ENERGY STAR...

    Science.gov (United States)

    2012-08-02

    ... Activities; Proposed Collection; Comment Request; EPA's ENERGY STAR Program in the Commercial and Industrial... this action are participants in EPA's ENERGY STAR Program in the Commercial and Industrial Sectors. Title: Information Collection Activities Associated with EPA's ENERGY STAR Program in the Commercial and...

  12. 40 CFR 725.17 - Consultation with EPA.

    Science.gov (United States)

    2010-07-01

    ... ACT REPORTING REQUIREMENTS AND REVIEW PROCESSES FOR MICROORGANISMS General Provisions and..., ATTN: Biotechnology Notice Consultation. Persons wishing to consult with EPA by telephone should call...

  13. EPA Communications Stylebook: Training and Education

    Science.gov (United States)

    It is the policy of EPA that our staff should have and develop good communications skills. Besides writing, style, and design skills, we seek to develop audience analysis and targeting, marketing and media selection, and computer skills.

  14. NIEHS/EPA Children's Environmental Health and Disease Prevention Research Centers: 2017 Annual Meeting Proceedings

    Science.gov (United States)

    The 2017 Annual Meeting of the NIEHS/EPA Children’s Environmental Health and Disease Prevention Research Centers was hosted by EPA in collaboration with NIEHS and the Pediatric Environmental Health Specialty Units (PEHSUs). The meeting was held at the EPA Region 9 offices i...

  15. Histamine as an emergent indoor contaminant: Accumulation and persistence in bed bug infested homes.

    Directory of Open Access Journals (Sweden)

    Zachary C DeVries

    Full Text Available Histamine is used in bronchial and dermal provocation, but it is rarely considered an environmental risk factor in allergic disease. Because bed bugs defecate large amounts of histamine as a component of their aggregation pheromone, we sought to determine if histamine accumulates in household dust in bed bug infested homes, and the effects of bed bug eradication with spatial heat on histamine levels in dust. We collected dust in homes and analyzed for histamine before, and up to three months after bed bug eradication. Histamine levels in bed bug infested homes were remarkably high (mean = 54.6±18.9 μg/100 mg of sieved household dust and significantly higher than in control homes not infested with bed bugs (mean < 2.5±1.9 μg/100 mg of sieved household dust. Heat treatments that eradicated the bed bug infestations failed to reduce histamine levels, even three months after treatment. We report a clear association between histamine levels in household dust and bed bug infestations. The high concentrations, persistence, and proximity to humans during sleep suggest that bed bug-produced histamine may represent an emergent contaminant and pose a serious health risk in the indoor environment.

  16. EPA Region 1 Environmentally Sensitive Areas (Points)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This coverage represents point equivalents of environmentally sensitive areas in EPA New England. This coverage represents polygon equivalents of environmentally...

  17. Smart metering gateway works as Smart Home Energy Manager; Smart Metering Gateway als Smart Home Energy Manager

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Klaus-Dieter [SSV Software Systems GmbH, Hannover (Germany)

    2011-07-01

    The installation of smart meters together with real time consumption data visualization doesn't help to save energy CO2 emissions. With regards to refinancing options, the situation in Germany has been quite different since the middle of last year for buildings equipped with a photovoltaic system. If a heat pump system is also present, intelligent energy use in conjunction with smart meters can save considerable amounts of money. A Smart Home Energy Manager (SHEM) automates the energy saving. (orig.)

  18. History of heat pumps - Swiss contributions and international milestones

    Energy Technology Data Exchange (ETDEWEB)

    Zogg, M

    2008-05-15

    Compared to conventional boilers, heating by heat pumps cuts down fuel consumption and CO{sub 2} emissions to about 50%. Compared to electric resistance heating, the energy consumption is even reduced up to 80%. Therefore, the impressive market penetration growth of heat pumps will continue. Swiss pioneers were the first to realize functioning vapour recompression plants. The first European heat pumps were realized in Switzerland. To date it remains one of the heat pump champions. Swiss pioneering work in the development of borehole heat exchangers, sewage heat recovery, oil free piston compressors and turbo compressors is well known. The biggest heat pump ever built comes from Switzerland. Although there is a fairly comprehensive natural gas distribution grid, 75% of the new single-family homes built in Switzerland are currently heated by heat pumps. This paper presents some of the highlights of this success story focusing on Swiss developments and relating them to the international milestones. In order to indicate the direction in which the future development might go to, some recent Swiss research projects are presented as well. (author)

  19. Emission factors of modern wood-pellet heating units under typical heating conditions - Final report; Emissionsfaktoren moderner Pelletkessel unter typischen Heizbedingungen - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Good, J.; Nussbaumer, T.

    2009-12-15

    This final report for the Swiss Federal Office of Energy (SFOE) reports on the results of measurements made concerning the emission factors of two modern wood-pellet heating units under typical heating conditions. Using simulations, typical operation in single-family homes and apartment blocks were examined. Emissions during the different phases of operation were examined. Systems with and without buffer storage were also examined. The minimum running times to be striven for are quoted which would lead to a reduction of emissions to an acceptable level. The characteristic operating modes for the two heating units and the results obtained for various emissions are presented and discussed.

  20. On the Path to Zero Energy Homes

    Energy Technology Data Exchange (ETDEWEB)

    Merrigan, T.

    2001-03-30

    Just imagine living in Florida and your fantasies might turn to swaying palms, fresh orange juice and lots of air-conditioning. For most people, a summer spent in Florida's heat and humidity would be unbearable without it. So air-conditioning is a necessity. But it's also a big energy drain, accounting for about 35% of all electricity used in a typical Florida house. As the largest single source of energy consumption in Florida, a home's air-conditioning load represents the biggest energy challenge. The Florida Solar Energy Center (FSEC) designed a project to answer this challenge. Two homes were built with the same floor plan on near-by lots. The difference was that one (the ''control home'') conformed to local residential building practices, and the other (the ''Zero Energy home'') was designed with energy efficiency in mind and solar technology systems on the roof. The homes were then monitored carefully for energy use. The project's designers were looking to answer two important questions: Could a home in a climate such as central Florida's be engineered and built so efficiently that a relatively small PV system would serve the majority of its cooling needs--and even some of its daytime electrical needs? And, would that home be as comfortable and appealing as the conventional model built alongside it? The answer to both questions turned out to be a resounding yes. And the test was especially rigorous, because it was conducted in the summer of 1998--one of the hottest summers on record in Florida. This news is important for city planners, architects, builders, and homeowners not only in the Sunshine State, but elsewhere, too. The solar/energy efficiency combo worked so well in Florida that it can--and should--be tried in other parts of the country. This brochure describes the Zero Energy Homes concept using a case study.

  1. Flower garden trees' ability to absorb solar radiation heat for local heat reduction

    Science.gov (United States)

    Maulana, Muhammad Ilham; Syuhada, Ahmad; Hamdani

    2017-06-01

    Banda Aceh as an urban area tends to have a high air temperature than its rural surroundings. A simple way to cool Banda Aceh city is by planting urban vegetation such as home gardens or parks. In addition to aesthetics, urban vegetation plays an important role as a reducer of air pollution, oxygen producer, and reducer of the heat of the environment. To create an ideal combination of plants, knowledge about the ability of plants to absorb solar radiation heat is necessary. In this study, some types of flowers commonly grown by communities around the house, such as Michelia Champaka, Saraca Asoka, Oliander, Adenium, Codiaeum Variegatum, Jas Minum Sambac, Pisonia Alba, Variegata, Apium Graveolens, Elephantopus Scaber, Randia, Cordylin.Sp, Hibiscus Rosasinensis, Agave, Lili, Amarilis, and Sesamum Indicum, were examined. The expected benefit of this research is to provide information for people, especially in Banda Aceh, on the ability of each plant relationship in absorbing heat for thermal comfort in residential environments. The flower plant which absorbs most of the sun's heat energy is Hibiscus Rosasinensis (kembang sepatu) 6.2 Joule, Elephantopus Scaber.L (tapak leman) 4.l Joule. On the other hand, the lowest heat absorption is Oliander (sakura) 0.9 Joule.

  2. EPA Region 1 - Map Layers for Valley ID Tool (Hosted Feature Service)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Valley Service Feature Layer hosts spatial data for EPA Region 1's Valley Identification Tool. These layers contain attribute information added by EPA R1 GIS...

  3. Procedures for EPA Libraries to Obtain Materials through Interlibrary Loan/Document Delivery

    Science.gov (United States)

    The purpose of this document is to establish Agency-wide procedures by which EPA libraries obtain materials for Agency employees and authorized EPA contractors through interlibrary loan (ILL) and other document delivery methods.

  4. Current status of and problems in ice heat storage systems contributing to improving load rate. Proliferation of the ice heat storage type air conditioning system and roles of the Heat Pump and Heat Storage Center; Fukaritsu kaizen ni kokensuru kori chikunetsu system no genjo to kadai. Kori chikunetsushiki kucho system no fukyu to heat pump chikunetsu center no yakuwari

    Energy Technology Data Exchange (ETDEWEB)

    Miyata, T.

    1998-02-01

    This paper introduces the roles played by the `Heat Pump and Heat Storage Center`. This foundation had been performing research and development and international information exchange in devices and equipment as the `Heat Pump Technology Development Center`. Development of heat storage type air conditioning systems as a measure for load leveling, and efforts of their proliferation and enlightenment were added to the business activities. As a result, the foundation`s name was changed to the present name. Its activities being planned and performed include: interest supplementing operation for installation of an air conditioning system of the heat pump system using storage of latent heat such as ice heat storage, holding seminars for promoting proliferation of the ice heat storage type air conditioning system, opening the home page, participation in exhibitions of various types, and preparation of different publicity tools. More specifically, carrying series advertisements in newspapers and magazines, holding nation-wide symposiums tying up with Japan Economic Press, publishing an organ newspaper targeted at both of experts and general people, and preparation of general pamphlets to introduce comprehensively the information about heat storage. 3 figs., 1 tab.

  5. 48 CFR 1552.203-71 - Display of EPA Office of Inspector General Hotline poster.

    Science.gov (United States)

    2010-10-01

    ... Inspector General Hotline poster. 1552.203-71 Section 1552.203-71 Federal Acquisition Regulations System... Provisions and Clauses 1552.203-71 Display of EPA Office of Inspector General Hotline poster. As prescribed... all contract options. Display of EPA Office of Inspector General Hotline Poster (AUG 2000) (a) For EPA...

  6. 48 CFR 1552.219-71 - Procedures for Participation in the EPA Mentor-Protege Program.

    Science.gov (United States)

    2010-10-01

    ... Participation in the EPA Mentor-Protege Program. 1552.219-71 Section 1552.219-71 Federal Acquisition Regulations... Texts of Provisions and Clauses 1552.219-71 Procedures for Participation in the EPA Mentor-Protege... EPA Mentor-Protege Program (OCT 2000) (a) This provision sets forth the procedures for participation...

  7. Northwest Energy Efficient Manufactured Housing Program High-Performance Test Homes

    Energy Technology Data Exchange (ETDEWEB)

    Hewes, Tom [Building America Partnership for Improved Residential Construction, Corvallis, OR (United States); Peeks, Brady [Building America Partnership for Improved Residential Construction, Corvallis, OR (United States)

    2015-09-01

    This project represents the third phase of a multi-year effort to develop and bring to market a High Performance Manufactured Home (HPMH), which is intended to make significant progress toward performing as zero-net-energy ready. The scope of this project involved building four HPMH prototypes, resulting in what is expected to be a 30% savings relative to the Building America Benchmark. (The actual percent savings varies depending on choice of heating equipment and climate zone). Previous phases of this project created a HPMH specification and prototyped individual measures from the package to obtain engineering approvals and develop preliminary factory construction processes. This report describes the project team's work during 2014 to build prototype homes to the HPMH specifications and to monitor the homes for energy performance and durability during 2014. Monitoring is expected to continue into 2016.

  8. 76 FR 42707 - Amendment of OIG Hotline Allegation System (EPA-30)

    Science.gov (United States)

    2011-07-19

    ... . The http://www.regulations.gov Web site is an ``anonymous access'' system, which means EPA will not... docket and made available on the Internet. If you submit an electronic comment, EPA recommends that you... the complainant (except for anonymous complainants), date complaint received, program area, nature and...

  9. Impacts of the Japan-Mexico EPA on Bilateral Trade

    OpenAIRE

    ANDO Mitsuyo; URATA Shujiro

    2011-01-01

    This paper examines the impacts of the Japan-Mexico EPA on bilateral trade by using two different types of information, trade statistics and the EPA utilization rate. Using trade data, we found that Japan's exports of built-up cars, auto parts, base metals, electrical machinery, precision machinery, and ballpoint pens to Mexico increased sharply. We also found that Japan's imports of live animals and products, leather, and footwear with leather from Mexico increased significantly. These are s...

  10. EPA RE-Powering Mapper Solar on Landfills

    Data.gov (United States)

    U.S. Environmental Protection Agency — The U.S. Environmental Protection Agency (EPA) Office of Land and Emergency Management (OLEM) Office of Communications, Partnerships and Analysis (OCPA) initiated...

  11. EPA Facility Registry Service (FRS): RCRA_INACTIVE

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of hazardous waste...

  12. EPA Facility Registry Service (FRS): RCRA_ACTIVE

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of active hazardous...

  13. EPA Linked Open Data: Facility Registry Service

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Facility Registry Service (FRS) identifies facilities, sites, or places subject to environmental regulation or of environmental interest to EPA programs or...

  14. EPA Facility Registry Service (FRS): RCRA_TSD

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of Hazardous Waste...

  15. U.S. EPAs Geospatial Data Access Project

    Data.gov (United States)

    U.S. Environmental Protection Agency — To improve public health and the environment, the United States Environmental Protection Agency (EPA) collects information about facilities, sites, or places subject...

  16. Registry of EPA Applications, Models, and Databases

    Data.gov (United States)

    U.S. Environmental Protection Agency — READ is EPA's authoritative source for information about Agency information resources, including applications/systems, datasets and models. READ is one component of...

  17. EPA and DHA in blood cell membranes from acute coronary syndrome patients and controls.

    Science.gov (United States)

    Block, Robert C; Harris, William S; Reid, Kimberly J; Sands, Scott A; Spertus, John A

    2008-04-01

    Increased blood levels of the omega-3 fatty acids (FA) eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) have been inversely associated with risk for sudden cardiac death, but their relationship with acute coronary syndromes (ACS) is unclear. We hypothesized that the EPA+DHA content of blood cell membranes, as a percent of total FAs, is reduced in ACS patients relative to matched controls. We measured the content of EPA+DHA in 768 ACS patients and 768 age-, sex- and race-matched controls. The association with ACS case status of blood cell EPA+DHA [both by a 1 unit change and by category (low, or =8%)] was assessed using multivariate conditional logistic regression models adjusting for matching variables and smoking status, alcohol use, diabetes, body mass index, serum lipids, education, family history of coronary artery disease, personal histories of myocardial infarction and hypertension, and statin, aspirin, and other antiplatelet drug use. The combined groups had a mean age of 61+/-12 years, 66% were male, and 92% were Caucasian. The EPA+DHA content was 20% lower in cases than controls (3.4+/-1.6 vs. 4.25+/-2.0%, pACS event was 0.58 (95% CI 0.42-0.80), in the intermediate EPA+DHA group and was 0.31 (95% CI 0.14-0.67; p for trend ACS case status increased incrementally as the EPA+DHA content decreased suggesting that low EPA+DHA may be associated with increased risk for ACS.

  18. Analysis of high heat flux testing of mock-ups

    International Nuclear Information System (INIS)

    Salavy, J.-F.; Giancarli, L.; Merola, M.; Picard, F.; Roedig, M.

    2003-01-01

    ITER EU Home Team is performing a large R and D effort in support of the development of high heat flux components for ITER. In this framework, this paper describes the thermal analyses, the fatigue lifetime evaluation and the transient VDE with material melting related to the high heat flux thermo-mechanical tests performed in the JUDITH facility. It reports on several mock-ups representative of different proposed component designs based on Be, W and CFC as armour materials

  19. Engineering of EPA/DHA omega-3 fatty acid production by Lactococcus lactis subsp. cremoris MG1363.

    Science.gov (United States)

    Amiri-Jami, Mitra; Lapointe, Gisele; Griffiths, Mansel W

    2014-04-01

    Eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) have been shown to be of major importance in human health. Therefore, these essential polyunsaturated fatty acids have received considerable attention in both human and farm animal nutrition. Currently, fish and fish oils are the main dietary sources of EPA/DHA. To generate sustainable novel sources for EPA and DHA, the 35-kb EPA/DHA synthesis gene cluster was isolated from a marine bacterium, Shewanella baltica MAC1. To streamline the introduction of the genes into food-grade microorganisms such as lactic acid bacteria, unnecessary genes located upstream and downstream of the EPA/DHA gene cluster were deleted. Recombinant Escherichia coli harboring the 20-kb gene cluster produced 3.5- to 6.1-fold more EPA than those carrying the 35-kb DNA fragment coding for EPA/DHA synthesis. The 20-kb EPA/DHA gene cluster was cloned into a modified broad-host-range low copy number vector, pIL252m (4.7 kb, Ery) and expressed in Lactococcus lactis subsp. cremoris MG1363. Recombinant L. lactis produced DHA (1.35 ± 0.5 mg g(-1) cell dry weight) and EPA (0.12 ± 0.04 mg g(-1) cell dry weight). This is believed to be the first successful cloning and expression of EPA/DHA synthesis gene cluster in lactic acid bacteria. Our findings advance the future use of EPA/DHA-producing lactic acid bacteria in such applications as dairy starters, silage adjuncts, and animal feed supplements.

  20. Mortality during a Large-Scale Heat Wave by Place, Demographic Group, Internal and External Causes of Death, and Building Climate Zone.

    Science.gov (United States)

    Joe, Lauren; Hoshiko, Sumi; Dobraca, Dina; Jackson, Rebecca; Smorodinsky, Svetlana; Smith, Daniel; Harnly, Martha

    2016-03-09

    Mortality increases during periods of elevated heat. Identification of vulnerable subgroups by demographics, causes of death, and geographic regions, including deaths occurring at home, is needed to inform public health prevention efforts. We calculated mortality relative risks (RRs) and excess deaths associated with a large-scale California heat wave in 2006, comparing deaths during the heat wave with reference days. For total (all-place) and at-home mortality, we examined risks by demographic factors, internal and external causes of death, and building climate zones. During the heat wave, 582 excess deaths occurred, a 5% increase over expected (RR = 1.05, 95% confidence interval (CI) 1.03-1.08). Sixty-six percent of excess deaths were at home (RR = 1.12, CI 1.07-1.16). Total mortality risk was higher among those aged 35-44 years than ≥ 65, and among Hispanics than whites. Deaths from external causes increased more sharply (RR = 1.18, CI 1.10-1.27) than from internal causes (RR = 1.04, CI 1.02-1.07). Geographically, risk varied by building climate zone; the highest risks of at-home death occurred in the northernmost coastal zone (RR = 1.58, CI 1.01-2.48) and the southernmost zone of California's Central Valley (RR = 1.43, CI 1.21-1.68). Heat wave mortality risk varied across subpopulations, and some patterns of vulnerability differed from those previously identified. Public health efforts should also address at-home mortality, non-elderly adults, external causes, and at-risk geographic regions.

  1. Level III Ecoregions of EPA Region 8

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions for EPA Administrative Regions were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the...

  2. Springs, US EPA Region 9, 2013, SDWIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPAâ??s Safe Drinking Water Information System (SDWIS) databases store information about drinking water. The federal version (SDWIS/FED) stores the information EPA...

  3. Reservoirs, US EPA Region 9, 2013, SDWIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPAâ??s Safe Drinking Water Information System (SDWIS) databases store information about drinking water. The federal version (SDWIS/FED) stores the information EPA...

  4. EPA Facility Registry Service (FRS): ER_TRI

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  5. EPA Facility Registry Service (FRS): ER_TSCA

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  6. EPA Facility Registry Service (FRS): RCRA_LQG

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  7. EPA Facility Registry Service (FRS): AIRS_AFS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  8. EPA Facility Registry Service (FRS): RCRA_TRANS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  9. Level IV Ecoregions of EPA Region 8

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions for EPA Administrative Regions were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the...

  10. Level IV Ecoregions of EPA Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions for EPA Administrative Regions were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the...

  11. Level III Ecoregions of EPA Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions for EPA Administrative Regions were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the...

  12. EPA Facility Registry Service (FRS): ER_RMP

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  13. EPA Facility Registry Service (FRS): ER_RCRATSD

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  14. EPA Facility Registry Service (FRS): ER_EPLAN

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  15. EPA Facility Registry Service (FRS): PCS_NPDES

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  16. EPA Facility Registry Service (FRS): ER_CERCLIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link...

  17. EPA Facility Registry Service (FRS): CERCLIS_NPL

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that are...

  18. EPA Facility Registry Service (FRS): ER_FRP

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains location and facility identification information from EPA's Facility Registry System (FRS) for the subset of facilities that link to Facility...

  19. EPA Facility Registry Service (FRS): AIRS_AQS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  20. Coping with EPA's new petroleum industry storm water permits

    International Nuclear Information System (INIS)

    Veal, S.C.; Whitescarver, J.P.

    1994-01-01

    The United States Environmental Protection Agency has just released for public comment its so-called multi-sector industry specific storm water permit. This permit -- developed in response to the 730 group storm water permit applications submitted in 1992 to EPA -- proposes the establishment of specific runoff sampling and facility design requirements for at least two petroleum industry sectors. This proposed permit establishes specific conditions for the oil and gas extraction section (SIC group 13) and for lubricant manufacturers (SIC 2992). Permit conditions are also established for allied industrial sectors such as the chemical, transportation and asphalt materials industries. By most standards, the proposed permit is much tougher than EPA's baseline general permit for storm water discharges which was released in September of 1992. For example, under the proposal, most industries are required to perform periodic storm water sampling. EPA has also established storm water effluent and performance standards for several industrial categories. This paper will discuss the petroleum industry specific conditions of the new permit. The paper will also discuss the results of the industry-wide storm water sampling efforts undertaken by more than 300 oil patch facilities across the country. In particular, sampling results will be discussed in the context to the permit conditions proposed by EPA. The paper will also discuss strategies for dealing with the new permits

  1. USEPA Geospatial Metadata EPA Region 2 All Regulated Facilities GIS layer PUB.

    Data.gov (United States)

    U.S. Environmental Protection Agency — This ArcGIS 10.2 point feature class (All Regulated Facilities [R2] Public contains a unique record for every EPA Regulated Facility in EPA Region 2 (NYS, NJ, Puerto...

  2. 2004 Toxic Release Inventory Sites in Louisiana, Geographic NAD83, EPA (2006) [toxic_release_inventory_site_LA_EPA_2004

    Data.gov (United States)

    Louisiana Geographic Information Center — Data extracted from the EPA Toxics Release Inventory (TRI) system for reporting year 2004. The dataset contains facility identification, submitted and/or preferred...

  3. Necessity for usage of geothermal heat pump

    International Nuclear Information System (INIS)

    Dimitrov, Konstantin; Armenski, Slave; Gacevski, Marijan

    2004-01-01

    Every day we are witnesses of constantly rapid increase of consumption of Electric energy in R. of Macedonia as so as in the other countries in all the world. This rapid increase of consumption of Electric energy independent of a lot of electrical units, which are applying in human life like: homes, administration and publication objects, as well as in industry. All of this conditions make us to thinking how is possible more rational consumption of electric energy in all areas in human life. One of the possible manners to reduce the consumption of electrical energy for heating and cooling is to use geothermal heat pumps. In this paper will be proposed geothermal heat pump, which is going to use the heat of earth by vertical and horizontal cupper pipe heat exchanger with data from-GHP (Geothermal Heat Pump) NORDIC, factory in Canada. Also, it will be examined all parameters and done comparison with already existing ones. It is analyzed comparison of GHP with other energy units and what it means for rational consumption of electric energy, economic saving and ecology saving. (Author)

  4. Endangered Species Case – Northwest Center for Alternatives to Pesticides v. EPA

    Science.gov (United States)

    EPA is reinstating streamside no-spray buffer zones to protect endangered or threatened Pacific salmon and steelhead in California, Oregon and Washington State, which were originally established in prior litigation brought against EPA by WTC and others.

  5. Level IV Ecoregions of EPA Region 5

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  6. Level IV Ecoregions of EPA Region 10

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  7. Level IV Ecoregions of EPA Region 2

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  8. Level IV Ecoregions of EPA Region 3

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  9. Level III Ecoregions of EPA Region 2

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  10. Level III Ecoregions of EPA Region 4

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  11. Level IV Ecoregions of EPA Region 7

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  12. Level IV Ecoregions of EPA Region 6

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  13. Level IV Ecoregions of EPA Region 1

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  14. Level III Ecoregions of EPA Region 1

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  15. Level III Ecoregions of EPA Region 10

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  16. Level IV Ecoregions of EPA Region 4

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  17. Level III Ecoregions of EPA Region 3

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  18. Level III Ecoregions of EPA Region 7

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  19. EPA Facility Registry Service (FRS): Power Plants

    Data.gov (United States)

    U.S. Environmental Protection Agency — This GIS dataset contains data on power plants, based on the Energy Information Administration's EIA-860 dataset and supplemented with data from EPA's Facility...

  20. Level III Ecoregions of EPA Region 5

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  1. Level III Ecoregions of EPA Region 6

    Data.gov (United States)

    U.S. Environmental Protection Agency — Ecoregions by EPA region were extracted from the seamless national shapefile. Ecoregions denote areas of general similarity in ecosystems and in the type, quality,...

  2. Design and engineering of a gas-engine driven heat pump heating station including heat distribution system and utilization of waste heat from an ice rink for the residential area Dorsten - Maria Lindenhof. Planung eines Gasmotor-Waermepumpenheizwerkes mit angeschlossenem Waermeverteilungsnetz und Abwaermenutzung einer Eisenbahn fuer das zentralstaedtische Gebiet 'Maria-Lindenhof' in Dorsten

    Energy Technology Data Exchange (ETDEWEB)

    Huelsemann, R.

    1984-05-01

    A gas-engine driven heat pump heating station including the required heat destribution system and utilization of waste heat from an ice rink to be realized in the residential area Dorsten - Maria Lindenhof. The total heat capacity was to be reached in two stages, corresponding to the progress of the building and housing structure in this specific area: First stage of construction 5,6 MW, final stage of construction 7,6 MW. With regard to the final stage of construction only a relatively small part of the buildings is provided with heating systems designed for supply and return temperatures of 90/70/sup 0/C respectively. The old people's home built in 1980 was already equipped with low temperature heating systems and all buildings still to be built shall be provided with low-temperature systems. As far as old heating systems are concerned, the required measures must be taken to reduce the temperature in the return lines.

  3. Expanding Horizons with Chameleon: Team Missouri’s Innovative Home Automation System

    Directory of Open Access Journals (Sweden)

    Bryan Glass

    2010-06-01

    Full Text Available Team Missouri’s 2009 Solar Decathlon entry featured a revolutionary home automation system, Chameleon, promoting both convenience and energy savings. This was accomplished using the typical controls of a convenience based automation system, while maintaining user set points, such as a home’s ambient temperature, in the most energy efficient manner. Environmental features of the system include controls for home heating, ventilation and air conditioning, lighting, windows, shades, appliances, indoor air quality, as well as indoor and outdoor irrigation. Further analysis and refinement to the prototype system displayed at the competition is also presented in this paper.

  4. An adopter-centric approach to analyze the diffusion patterns of innovative residential heating systems in Sweden

    International Nuclear Information System (INIS)

    Mahapatra, Krushna; Gustavsson, Leif

    2008-01-01

    Innovation and diffusion of renewable energy technologies play a major role in mitigation of climate change. In Sweden replacing electric and oil heating systems with innovative heating systems such as district heating, heat pumps and wood pellet boilers in detached homes is a significant mitigation option. Using an adopter-centric approach, we analyzed the influence of investment subsidy on conversion of resistance heaters and oil boilers, and the variation in diffusion pattern of district heating, heat pumps and pellet boilers in Swedish detached homes. Results from questionnaire surveys of 1500 randomly selected homeowners in September 2004 and January 2007 showed that more than 80% of the respondents did not intend to install a new heating system. Hence, about 37% of the homeowners still have electric and oil heating systems. The government investment subsidy was important for conversion from a resistance heater, but not from an oil boiler. This is because homeowners currently replacing their oil boilers are the laggards, while those replacing resistance heaters are the 'early adopters'. Economic aspects and functional reliability were the most important factors for the homeowners when considering a new heating system. There is a variation in the perceived advantages associated with each of the innovative heating systems and therefore, the diffusion patterns of such systems vary. Installers and interpersonal sources were the most important communication channels for information on heating systems

  5. An adopter-centric approach to analyze the diffusion patterns of innovative residential heating systems in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Mahapatra, Krushna; Gustavsson, Leif [Ecotechnology, Mid Sweden University, 831 25 Oestersund (Sweden)

    2008-02-15

    Innovation and diffusion of renewable energy technologies play a major role in mitigation of climate change. In Sweden replacing electric and oil heating systems with innovative heating systems such as district heating, heat pumps and wood pellet boilers in detached homes is a significant mitigation option. Using an adopter-centric approach, we analyzed the influence of investment subsidy on conversion of resistance heaters and oil boilers, and the variation in diffusion pattern of district heating, heat pumps and pellet boilers in Swedish detached homes. Results from questionnaire surveys of 1500 randomly selected homeowners in September 2004 and January 2007 showed that more than 80% of the respondents did not intend to install a new heating system. Hence, about 37% of the homeowners still have electric and oil heating systems. The government investment subsidy was important for conversion from a resistance heater, but not from an oil boiler. This is because homeowners currently replacing their oil boilers are the laggards, while those replacing resistance heaters are the 'early adopters'. Economic aspects and functional reliability were the most important factors for the homeowners when considering a new heating system. There is a variation in the perceived advantages associated with each of the innovative heating systems and therefore, the diffusion patterns of such systems vary. Installers and interpersonal sources were the most important communication channels for information on heating systems. (author)

  6. Quality Management Plan for EPA Region 1

    Science.gov (United States)

    The QMP describes policies, procedures & management systems within EPA NE that govern quality assurance & quality control activities supporting the transparency & scientific defensibility of environmental data collected, used & disseminated by the Region.

  7. EPA Linked Open Data: Toxics Release Inventory

    Data.gov (United States)

    U.S. Environmental Protection Agency — TRI is a publicly available EPA database reported annually by certain covered industry groups, as well as federal facilities. It contains information about more than...

  8. Methane Tracking and Mitigation Options - EPA CMOP

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains the sub-model for EPA's MARKAL model, which tracks methane emissions from the energy system, and limited other sources (landfills and manure...

  9. EPA Linked Open Data: Chemical Data Reporting

    Data.gov (United States)

    U.S. Environmental Protection Agency — This resource consists of the Chemical Data Reporting database that supports the Toxic Substances Control Act (TSCA) of 1976, which provides EPA with authority to...

  10. US EPA - A*Star Partnership - Accelerating the Acceptance of ...

    Science.gov (United States)

    The path for incorporating new alternative methods and technologies into quantitative chemical risk assessment poses a diverse set of scientific challenges. Some of these challenges include development of relevant and predictive test systems and computational models to integrate and extrapolate experimental data, and rapid characterization and acceptance of these systems and models. The series of presentations will highlight a collaborative effort between the U.S. Environmental Protection Agency (EPA) and the Agency for Science, Technology and Research (A*STAR) that is focused on developing and applying experimental and computational models for predicting chemical-induced liver and kidney toxicity, brain angiogenesis, and blood-brain-barrier formation. In addressing some of these challenges, the U.S. EPA and A*STAR collaboration will provide a glimpse of what chemical risk assessments could look like in the 21st century. Presentation on US EPA – A*STAR Partnership at international symposium on Accelerating the acceptance of next-generation sciences and their application to regulatory risk assessment in Singapore.

  11. Environmental protection belongs to the public: A vision for citizen science at EPA

    Science.gov (United States)

    Parker, A.; Dosemagen, S.

    2017-12-01

    As a collaborative and open approach to science, citizen science has the potential make science more actionable, applicable, and usable, especially when designed with scientists, communities and decision-makers as partners. In response to recent interest in citizen science from the US Environmental Protection Agency, the National Advisory Council for Environmental Policy and Technology provided EPA with advice and recommendations on how to integrate citizen science into the core work of EPA. The Council's 28 members—representatives of academia; business and industry; nongovernmental organizations; and state, local and tribal governments—identifies citizen science as an invaluable opportunity for EPA to strengthen public support for EPA's mission and the best approach for the Agency to connect with the public on environmental protection. The report recommends that EPA embrace citizen science as a core tenet of environmental protection, invest in citizen science for communities, partners, and the Agency, enable the use of citizen science data at the Agency, integrate citizen science into the full range of work of EPA. This presentation will outline principles and strategy for integrating citizen science into science and policy at the national level, increasing the usability of citizen science data for decision-making and policy, and leveraging citizen science for environmental protection.

  12. Antibacterial and antibiofilm activities of docosahexaenoic acid (DHA) and eicosapentaenoic acid (EPA) against periodontopathic bacteria.

    Science.gov (United States)

    Sun, Mengjun; Zhou, Zichao; Dong, Jiachen; Zhang, Jichun; Xia, Yiru; Shu, Rong

    2016-10-01

    Docosahexaenoic acid (DHA) and eicosapentaenoic acid (EPA) are two major omega-3 polyunsaturated fatty acids (n-3 PUFAs) with antimicrobial properties. In this study, we evaluated the potential antibacterial and antibiofilm activities of DHA and EPA against two periodontal pathogens, Porphyromonas gingivalis (P. gingivalis) and Fusobacterium nucleatum (F. nucleatum). MTT assay showed that DHA and EPA still exhibited no cytotoxicity to human oral tissue cells when the concentration came to 100 μM and 200 μM, respectively. Against P. gingivalis, DHA and EPA showed the same minimum inhibitory concentration (MIC) of 12.5 μM, and a respective minimum bactericidal concentration (MBC) of 12.5 μM and 25 μM. However, the MIC and MBC values of DHA or EPA against F. nucleatum were both greater than 100 μM. For early-stage bacteria, DHA or EPA displayed complete inhibition on the planktonic growth and biofilm formation of P. gingivalis from the lowest concentration of 12.5 μM. And the planktonic growth of F. nucleatum was slightly but not completely inhibited by DHA or EPA even at the concentration of 100 μM, however, the biofilm formation of F. nucleatum at 24 h was significantly restrained by 100 μM EPA. For exponential-phase bacteria, 100 μM DHA or EPA completely killed P. gingivalis and significantly decreased the viable counts of F. nucleatum. Meanwhile, the morphology of P. gingivalis was apparently damaged, and the virulence factor gene expression of P. gingivalis and F. nucleatum was strongly downregulated. Besides, the viability and the thickness of mature P. gingivalis biofilm, together with the viability of mature F. nucleatum biofilm were both significantly decreased in the presence of 100 μM DHA or EPA. In conclusion, DHA and EPA possessed antibacterial activities against planktonic and biofilm forms of periodontal pathogens, which suggested that DHA and EPA might be potentially supplementary therapeutic agents for prevention

  13. Making Heat Visible

    Science.gov (United States)

    Goodhew, Julie; Pahl, Sabine; Auburn, Tim; Goodhew, Steve

    2015-01-01

    Householders play a role in energy conservation through the decisions they make about purchases and installations such as insulation, and through their habitual behavior. The present U.K. study investigated the effect of thermal imaging technology on energy conservation, by measuring the behavioral effect after householders viewed images of heat escaping from or cold air entering their homes. In Study 1 (n = 43), householders who received a thermal image reduced their energy use at a 1-year follow-up, whereas householders who received a carbon footprint audit and a non-intervention control demonstrated no change. In Study 2 (n = 87), householders were nearly 5 times more likely to install draught proofing measures after seeing a thermal image. The effect was especially pronounced for actions that addressed an issue visible in the images. Findings indicate that using thermal imaging to make heat loss visible can promote energy conservation. PMID:26635418

  14. EPA H2O User Manual

    Science.gov (United States)

    EPA H2O is a software tool designed to support research being conducted in the Tampa Bay watershed to provide information, data, and approaches and guidance that communities can use to examine alternatives when making strategic decisions to support a prosperous and environmentall...

  15. Substance Identification Information from EPA's Substance Registry

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Substance Registry Services (SRS) is the authoritative resource for basic information about substances of interest to the U.S. EPA and its state and tribal...

  16. Meet EPA Scientist Jody Shoemaker, Ph.D.

    Science.gov (United States)

    EPA research chemist Jody Shoemaker, Ph.D., works to support Agency efforts to protect drinking water. She helps develop methods for analyzing organic chemicals on the Drinking Water Contaminant Candidate List (CCL).

  17. Report: EPA Does Not Effectively Control or Monitor Imports of Hazardous Waste

    Science.gov (United States)

    Report #15-P-0172, July 6, 2015. The EPA lacks explicit authority to block imported shipments of hazardous waste that lack prior EPA consent. This could lead to improper handling and disposal, resulting in unknown human and environmental exposure to toxic

  18. Visual Analytics for Pattern Discovery in Home Care

    Science.gov (United States)

    Monsen, Karen A.; Bae, Sung-Heui; Zhang, Wenhui

    2016-01-01

    Summary Background Visualization can reduce the cognitive load of information, allowing users to easily interpret and assess large amounts of data. The purpose of our study was to examine home health data using visual analysis techniques to discover clinically salient associations between patient characteristics with problem-oriented health outcomes of older adult home health patients during the home health service period. Methods Knowledge, Behavior and Status ratings at discharge as well as change from admission to discharge that was coded using the Omaha System was collected from a dataset on 988 de-identified patient data from 15 home health agencies. SPSS Visualization Designer v1.0 was used to visually analyze patterns between independent and outcome variables using heat maps and histograms. Visualizations suggesting clinical salience were tested for significance using correlation analysis. Results The mean age of the patients was 80 years, with the majority female (66%). Of the 150 visualizations, 69 potentially meaningful patterns were statistically evaluated through bivariate associations, revealing 21 significant associations. Further, 14 associations between episode length and Charlson co-morbidity index mainly with urinary related diagnoses and problems remained significant after adjustment analyses. Through visual analysis, the adverse association of the longer home health episode length and higher Charlson co-morbidity index with behavior or status outcomes for patients with impaired urinary function was revealed. Conclusions We have demonstrated the use of visual analysis to discover novel patterns that described high-needs subgroups among the older home health patient population. The effective presentation of these data patterns can allow clinicians to identify areas of patient improvement, and time periods that are most effective for implementing home health interventions to improve patient outcomes. PMID:27466053

  19. About Region 3's Laboratory and Field Services at EPA's Environmental Science Center

    Science.gov (United States)

    Mission & contact information for EPA Region 3's Laboratory and Field Services located at EPA's Environmental Science Center: the Office of Analytical Services and Quality Assurance & Field Inspection Program

  20. Histamine as an emergent indoor contaminant: Accumulation and persistence in bed bug infested homes.

    Science.gov (United States)

    DeVries, Zachary C; Santangelo, Richard G; Barbarin, Alexis M; Schal, Coby

    2018-01-01

    Histamine is used in bronchial and dermal provocation, but it is rarely considered an environmental risk factor in allergic disease. Because bed bugs defecate large amounts of histamine as a component of their aggregation pheromone, we sought to determine if histamine accumulates in household dust in bed bug infested homes, and the effects of bed bug eradication with spatial heat on histamine levels in dust. We collected dust in homes and analyzed for histamine before, and up to three months after bed bug eradication. Histamine levels in bed bug infested homes were remarkably high (mean = 54.6±18.9 μg/100 mg of sieved household dust) and significantly higher than in control homes not infested with bed bugs (mean emergent contaminant and pose a serious health risk in the indoor environment.