WorldWideScience

Sample records for environmental trace analysis

  1. Environmental sampling for trace analysis

    International Nuclear Information System (INIS)

    Markert, B.

    1994-01-01

    Often too little attention is given to the sampling before and after actual instrumental measurement. This leads to errors, despite increasingly sensitive analytical systems. This is one of the first books to pay proper attention to representative sampling. It offers an overview of the most common techniques used today for taking environmental samples. The techniques are clearly presented, yield accurate and reproducible results and can be used to sample -air - water - soil and sediments - plants and animals. A comprehensive handbook, this volume provides an excellent starting point for researchers in the rapidly expanding field of environmental analysis. (orig.)

  2. Trace-element analysis in environmental sciences

    International Nuclear Information System (INIS)

    Valkovic, V.; Moschini, G.

    1988-01-01

    The use of charged-particle accelerators in trace-element analysis in the field of environmental sciences is described in this article. Nuclear reactions, charged-particle-induced X-ray emission as well as other nuclear and atomic processes can be used individually, or combined, in developing adequate analytical systems. In addition to concentration levels, concentration levels, concentration profiles can be measured, resulting in unique information. Some examples of experiments performed are described together with the suggestions for future measurements [pt

  3. Trace analysis

    International Nuclear Information System (INIS)

    Warner, M.

    1987-01-01

    What is the current state of quantitative trace analytical chemistry? What are today's research efforts? And what challenges does the future hold? These are some of the questions addressed at a recent four-day symposium sponsored by the National Bureau of Standards (NBS) entitled Accuracy in Trace Analysis - Accomplishments, Goals, Challenges. The two plenary sessions held on the first day of the symposium reviewed the history of quantitative trace analysis, discussed the present situation from academic and industrial perspectives, and summarized future needs. The remaining three days of the symposium consisted of parallel sessions dealing with the measurement process; quantitation in materials; environmental, clinical, and nutrient analysis; and advances in analytical techniques

  4. Instrumental neutron activation analysis in environmental studies of trace elements

    International Nuclear Information System (INIS)

    Salmon, L.

    1975-06-01

    The application of a routine instrumental nuclear method is described in relation to environmental surveys and studies. A working rather than formal review is made of the techniques applied with particular reference to the data processing methods involved. The elements measured by instrumental activation analysis were: Ag, Al, As, Au, Ba, Br, Ca, Ce, Cl, Cd, Co, Cr, Cs, Cu, Fe, Hg, I, In, La, Mn, Na, Ni, Pb, Rb, Sb, Sc, Se, Th, Ti, U, V, W, Zn. (author)

  5. Analysis of trace uranium and plutonium in environmental water sample by ICP-MS

    International Nuclear Information System (INIS)

    Liu Xuemei

    2004-12-01

    The analysis of trace Uranium and Plutonium in environmental water is very important in the environment inspect. The preparation method of water samples are introduced and several common used method are compared. The analysis process and the calibration method with ICP-MS are discussed in detail considering present conditions. (author)

  6. Determination of short-lived trace elements in environmental samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Wardani, S.; Sihombing, E.; Hamzah, A.; Rochidi; Hery, P.S.; Hartaman, S.; Iman, J.

    1998-01-01

    Concentration of a short-lived trace elements in environmental samples were determined by neutron activation analysis, a counting loss often occur due to the high counting rate. A Pile-Up Rejecter (PUR) electric circuit was installed in counting a short-lived trace elements by a γ-ray spectrometer in order to correct a counting loss. The samples were irradiated for 30∼60 seconds at neutron flux of 3.5 x 10 12 n.cm -2 .s -1 , then the samples cooled for 120 second and counted for 180 second using this system. The nuclides concentration in the varieties environmental samples have a difference analysis result, was more accurate and precise, which the measured result would be 30 % more higher by PUR system than the result would be counted using a conventional γ-ray spectrometry method

  7. Preconcentration of traces of radionuclides and elements with foamed polyurethane sorbents in the analysis of environmental samples

    International Nuclear Information System (INIS)

    Palagyi, S.; Braun, T.

    1986-01-01

    The importance of preconcentration and the permanent need of efficient preconcentrating agents in environmental analysis are pointed out. Foamed polyurethane sorbents draw attention as novel agents in separation chemistry. A survey is presented of recent applications of unloaded and reagent-loaded open-cell type resilient polyurethane foams in the separation and preconcentration of radionuclides from environmental samples, and of the latest uses of these foams in the preconcentration and detection of traces of some, mainly inorganic materials in environmental samples, using radioanalytical techniques. Possible future uses of polyurethane foams in trace element detection in environmental analysis are outlined. (author)

  8. Establishment of a clean laboratory for ultra trace analysis of nuclear materials in safeguards environmental samples

    International Nuclear Information System (INIS)

    Hanzawa, Yukiko; Magara, Masaaki; Watanabe, Kazuo

    2003-01-01

    The Japan Atomic Energy Research Institute has established a cleanroom facility with cleanliness of ISO Class 5: the Clean Laboratory for Environmental Analysis and Research (CLEAR). It was designed to be used for the analysis of nuclear materials in environmental samples mainly for the safeguards, in addition to the Comprehensive Nuclear-Test-Ban Treaty verification and research on environmental sciences. The CLEAR facility was designed to meet conflicting requirements of a cleanroom and for handling of nuclear materials according to Japanese regulations, i.e., to avoid contamination from outside and to contain nuclear materials inside the facility. This facility has been intended to be used for wet chemical treatment, instrumental analysis and particle handling. A fume-hood to provide a clean work surface for handling of nuclear materials was specially designed. Much attention was paid to the selection of construction materials for use to corrosive acids. The performance of the cleanroom and analytical background in the laboratory are discussed. This facility has satisfactory specification required for joining the International Atomic Energy Agency Network of Analytical Laboratories. It can be concluded that the CLEAR facility enables analysis of ultra trace amounts of nuclear materials at sub-pictogram level in environmental samples. (author)

  9. Contribution of neutron activation analysis and radioanalytical techniques to trace element speciation in environmental analysis

    International Nuclear Information System (INIS)

    Gallorini, M.; Orvini, E.; Sabbioni, E.; Pietra, R.

    1984-01-01

    The feasibility of the NAA in contributing to trace element speciation in environmental and biological samples is shown by a few selected applications. They are: (i) the determination of different species of vanadium, arsenic and selenium in freshwater. The pre-irradiation treatments in which the different chemical species are selectively isolated are critically evaluated. Problems arising from possible contaminations or losses and from blanks are discussed; (ii) the use of NAA in metallobiochemical speciation once biochemical methods of cellular fractionation for the isolation of metallobiocomplexes are developed. Examples concern the biochemical speciation of vanadium in human blood and the development of a method for speciation of inorganic and organic arsenic compounds in biological samples. The use of radioanalytical techniques in developing the separation procedures of different trace metal chemical and biochemical species is also briefly discussed. 24 references, 5 figures, 4 tables

  10. Activation analysis of hair as an indicator of contamination of man by environmental trace element pollutants

    International Nuclear Information System (INIS)

    Ryabukhin, Yu.S.

    1976-10-01

    The burning of fossil fuel, discharges from metallurgical and chemical plants, the wide use of chemicals, and other human activities, result in releasing into the biosphere large quantities of elements which are found in relatively low concentrations in the human organism. The pollution of the biosphere by such trace elements, and in particular heavy metals, has reached such proportions that on the scale of significance of the factors causing the 'stressed' state of the environment of heavy metals occupy the second place and, according to forecasts, may in the future move on to the first. In the problem of pollution of the biosphere, man himself undoubtedly occupies the central position as a target. The pollution of air, soil and water, the contamination of micro-organisms, plants and animals are certainly growing into a serious threat and leading to heavy losses. However, it would be a real disaster if man himself became contaminated to levels giving rise to large scale harmful somatic or genetic effects. It is therefore an urgent problem today to determine the initial levels of trace elements in man and the extent of his contamination in areas where these elements are expected to show anomalous concentrations. Attention should be paid in the first place to those trace elements which probably play no physiological role, are particularly abundant in the environment, and have high toxicity (arsenic, mercury, lead, cadmium, etc.). Moreover, it should be born in mind that in anomalously high concentrations even the physiologically necessary trace elements (copper, zinc, manganese, fluorine, etc.) cause harmful effects. This paper justifies the use of hair samples as a biological indicator of environmental pollutants from physiological and morphological aspect and recommends on sample preparation and analysis methods

  11. Activation analysis of hair as an indicator of contamination of man by environmental trace element pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Ryabukhin, Yu S [ed.

    1976-10-01

    The burning of fossil fuel, discharges from metallurgical and chemical plants, the wide use of chemicals, and other human activities, result in releasing into the biosphere large quantities of elements which are found in relatively low concentrations in the human organism. The pollution of the biosphere by such trace elements, and in particular heavy metals, has reached such proportions that on the scale of significance of the factors causing the 'stressed' state of the environment of heavy metals occupy the second place and, according to forecasts, may in the future move on to the first. In the problem of pollution of the biosphere, man himself undoubtedly occupies the central position as a target. The pollution of air, soil and water, the contamination of micro-organisms, plants and animals are certainly growing into a serious threat and leading to heavy losses. However, it would be a real disaster if man himself became contaminated to levels giving rise to large scale harmful somatic or genetic effects. It is therefore an urgent problem today to determine the initial levels of trace elements in man and the extent of his contamination in areas where these elements are expected to show anomalous concentrations. Attention should be paid in the first place to those trace elements which probably play no physiological role, are particularly abundant in the environment, and have high toxicity (arsenic, mercury, lead, cadmium, etc.). Moreover, it should be born in mind that in anomalously high concentrations even the physiologically necessary trace elements (copper, zinc, manganese, fluorine, etc.) cause harmful effects. This paper justifies the use of hair samples as a biological indicator of environmental pollutants from physiological and morphological aspect and recommends on sample preparation and analysis methods.

  12. Liquid membrane extraction techniques for trace metal analysis and speciation in environmental and biological matrices

    Energy Technology Data Exchange (ETDEWEB)

    Ndungu, Kuria

    1999-04-01

    In this thesis, liquid-membrane-based methods for the analysis of trace metal species in samples of environmental and biological origin were developed. By incorporating extracting reagents in the membrane liquid, trace metal ions were selectively separated from humic-rich natural waters and urine samples, prior to their determination using various instrumental techniques. The extractions were performed in closed flow systems thus allowing easy automation of both the sample clean-up and enrichment. An acidic organophosphorus reagent (DEHPA) and a basic tetraalkylammonium reagent (Aliquat-336) were used as extractants in the membrane liquid to selectively extract and enrich cationic and anionic metal species respectively. A speciation method for chromium species was developed that allowed the determination of cationic Cr(III) species and anionic CR(VI) species in natural water samples without the need of a chromatographic separation step prior to their detection. SLM was also coupled on-line to potentiometric stripping analysis providing a fast and sensitive method for analysis of Pb in urine samples. A microporous membrane liquid-liquid extraction (MMLLE) method was developed for the determination of organotin compounds in natural waters that reduced the number of manual steps involved in the LLE of organotin compounds prior to their CC separation. Clean extracts obtained after running unfiltered humic-rich river water samples through the MMLLE flow system allowed selective determination of all the organotin compounds in a single run using GC-MS in the selected ion monitoring mode (SIM) 171 refs, 9 figs, 4 tabs

  13. Preconcentration of traces of radionuclides with sorbents based on spherical polyurethane membrane systems in the analysis of environmental samples

    International Nuclear Information System (INIS)

    Palagyi, S.; Braun, T.

    1986-01-01

    In the paper the importance of preconcentration and a permanent need for efficient preconcentrating agents in environmental analysis are pointed out. The increased attention is devoted to the foamed polyurethane sorbents as a novel advance in the separation chemistry. The paper has two main aims. The first is to present a survey of recent applications of unloaded and reagent loaded open-cell type resilient polyurethane foams to the separation and preconcentration of radionuclides from environmental samples. The second is to show the newest results in the use of these foams for the preconcentration and determination of traces of some mainly inorganic species in environmental samples by radioanalytical techniques. Some future possibilities of the use of polyurethane foams in trace elemental determinations in environmental analysis are also outlined. (author)

  14. Trace element analysis of environmental samples by multiple prompt gamma-ray analysis method

    International Nuclear Information System (INIS)

    Oshima, Masumi; Matsuo, Motoyuki; Shozugawa, Katsumi

    2011-01-01

    The multiple γ-ray detection method has been proved to be a high-resolution and high-sensitivity method in application to nuclide quantification. The neutron prompt γ-ray analysis method is successfully extended by combining it with the γ-ray detection method, which is called Multiple prompt γ-ray analysis, MPGA. In this review we show the principle of this method and its characteristics. Several examples of its application to environmental samples, especially river sediments in the urban area and sea sediment samples are also described. (author)

  15. The complementary use of radioanalytical methods and trace analysis methods for the characterisation of environmental IAEA reference materials

    International Nuclear Information System (INIS)

    De Regge, P.; Burns, K.; Campbell, M.; Makarewicz, M.; Markowicz, A.; Mattiuzzi, M.; Tajani, A.; Toervenyi, A.; Zeiller, E.

    2001-01-01

    The IAEA laboratories have access to both nuclear analytical methods and conventional instrumental methods for trace analysis for the characterisation of its environmental and biological reference materials. A technical concept integrating the homogeneity data, the recommended test portion mass and the uncertainty on the trace element concentrations is explored using a combination of INAA, XRF, ICP-MS, ICP-AES, and AAS. The above approach is illustrated by selected examples of reference materials currently under evaluation for their trace element content. They include some or all of the following elements Al, As, Br, Ca, Cd, Co, Cr, Cs, Cu, Fe, Hg, K, Mg, Mn, Mo, Na, Ni, Pb, Rb, Se, Sr, Th, U, Zn in environmental biomonitor organisms (lichen, algae) and air dust filters. (author)

  16. Resonant laser mass spectrometry for environmental and industrial chemical trace analysis

    International Nuclear Information System (INIS)

    Boesl, Ulrich; Rink, Joerg; Distelrath, Volker; Pueffel, Peter

    2001-01-01

    A promising new method for pollutant trace analysis is resonant laser mass spectrometry. It combines selectivity, sensitivity, and speed of measurement. In this paper, two examples of application are presented: exhaust analysis of combustion engines and analysis of polycylcic aromatic compounds in soil samples. The sensitivity of small, mobile instruments is discussed as well as alternative laser-based techniques in the case formation of cations by nanosecond lasers is improbable

  17. Tracing footprints of environmental events in tree ring chemistry using neutron activation analysis

    Science.gov (United States)

    Sahin, Dagistan

    The aim of this study is to identify environmental effects on tree-ring chemistry. It is known that industrial pollution, volcanic eruptions, dust storms, acid rain and similar events can cause substantial changes in soil chemistry. Establishing whether a particular group of trees is sensitive to these changes in soil environment and registers them in the elemental chemistry of contemporary growth rings is the over-riding goal of any Dendrochemistry research. In this study, elemental concentrations were measured in tree-ring samples of absolutely dated eleven modern forest trees, grown in the Mediterranean region, Turkey, collected and dated by the Malcolm and Carolyn Wiener Laboratory for Aegean and Near Eastern Dendrochronology laboratory at Cornell University. Correlations between measured elemental concentrations in the tree-ring samples were analyzed using statistical tests to answer two questions. Does the current concentration of a particular element depend on any other element within the tree? And, are there any elements showing correlated abnormal concentration changes across the majority of the trees? Based on the detailed analysis results, the low mobility of sodium and bromine, positive correlations between calcium, zinc and manganese, positive correlations between trace elements lanthanum, samarium, antimony, and gold within tree-rings were recognized. Moreover, zinc, lanthanum, samarium and bromine showed strong, positive correlations among the trees and were identified as possible environmental signature elements. New Dendrochemistry information found in this study would be also useful in explaining tree physiology and elemental chemistry in Pinus nigra species grown in Turkey. Elemental concentrations in tree-ring samples were measured using Neutron Activation Analysis (NAA) at the Pennsylvania State University Radiation Science and Engineering Center (RSEC). Through this study, advanced methodologies for methodological, computational and

  18. Improvenments in environmental trace analysis by GC-IR and LC-IR.

    NARCIS (Netherlands)

    Visser, T.; Vredenbregt, M.J.; Jong, A.P.J.M.; Somsen, G.W.; Hankemeier, T.; Velthorst, N.H.; Gooijer, C.; Brinkman, U.A.T.

    1997-01-01

    Research has been carried out to enlarge the potential of infrared (IR) spectrometry as a detector in gas and liquid chromatography (GC and LC). The study has been directed to applications in environmental analysis. Examples of recently obtained results are presented. The analyte detectability of

  19. Recent Improvements at CEA on Trace Analysis of Actinides in Environmental Samples

    International Nuclear Information System (INIS)

    Pointurier, F.; Hubert, A.; Faure, A.L.; Pottin, A.C.; Mourier, W.; Marie, O.

    2010-01-01

    In this paper, we present some results of R and D works conducted at CEA to improve on the one side the performance of the techniques already in use for detection of undeclared activities, and on the other side to develop new capabilities, either as alternative to the existing techniques or new methods that bring new information, complementary to the isotopic composition. For the trace analysis of plutonium in swipe samples by ICP-MS, we demonstrate that a thorough knowledge of the background in the actinide mass range is highly desirable. In order to avoid false plutonium detection in the femtogram range, correction from polyatomic interferences including mercury, lead or iridium atoms are in some case necessary. Efforts must be put on improving the purification procedure. Micro-Raman spectrometry allows determining the chemical composition of uranium compound at the scale of the microscopic object using a pre-location of the particles thanks to SEM and a relocation of these particles thanks to mathematical calculations. However, particles below 5 μm are hardly relocated and a coupling device between the SEM and the micro-Raman spectrometer for direct Raman analysis after location of a particle of interest is currently under testing. Lastly, laser ablation - ICP-MS is an interesting technique for direct isotopic or elemental analysis of various solid samples and proves to be a suitable alternative technique for particle analysis, although precision over isotopic ratio measurement is strongly limited by the short duration and irregularity of the signals. However, sensitivity and sample throughput are high and more developments are in progress to validate and improve this method. (author)

  20. Atom trap trace analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Z.-T.; Bailey, K.; Chen, C.-Y.; Du, X.; Li, Y.-M.; O' Connor, T. P.; Young, L.

    2000-05-25

    A new method of ultrasensitive trace-isotope analysis has been developed based upon the technique of laser manipulation of neutral atoms. It has been used to count individual {sup 85}Kr and {sup 81}Kr atoms present in a natural krypton sample with isotopic abundances in the range of 10{sup {minus}11} and 10{sup {minus}13}, respectively. The atom counts are free of contamination from other isotopes, elements,or molecules. The method is applicable to other trace-isotopes that can be efficiently captured with a magneto-optical trap, and has a broad range of potential applications.

  1. Atom trap trace analysis

    International Nuclear Information System (INIS)

    Lu, Z.-T.; Bailey, K.; Chen, C.-Y.; Du, X.; Li, Y.-M.; O'Connor, T. P.; Young, L.

    2000-01-01

    A new method of ultrasensitive trace-isotope analysis has been developed based upon the technique of laser manipulation of neutral atoms. It has been used to count individual 85 Kr and 81 Kr atoms present in a natural krypton sample with isotopic abundances in the range of 10 -11 and 10 -13 , respectively. The atom counts are free of contamination from other isotopes, elements,or molecules. The method is applicable to other trace-isotopes that can be efficiently captured with a magneto-optical trap, and has a broad range of potential applications

  2. Development for ultra-trace analysis method of U and Pu in safeguards environmental samples at the clean facility

    International Nuclear Information System (INIS)

    Takahashi, Masato; Magara, Masaaki; Sakurai, Satoshi

    2002-01-01

    Based on the strengthen safeguard program of the IAEA to detect undeclared nuclear activities and nuclear materials, the method of precise and accurate isotope ratio determination for uranium and plutonium in the environmental samples (cotton swipes) has been developed at JAERI. The samples should be treated in clean environment in order to secure the analytical reliability by eliminating external contamination from the samples containing trace amount of uranium and plutonium. Since the measurement by ICP-MS is favorable to bulk analysis from view points of analytical capacity and operation simplicity, we have studied sample preparation procedures for the trace amount of uranium and plutonium to be applied to ICP-MS. Up to the present, interfering factors involved during analytical processes and the ICP-MS measurement of uranium and plutonium were examined. As a result, uranium isotope measurement more than 100 pg became possible at JAERI clean facility by diminishing uranium blank introduced in the entire sample treatment procedure. And also, the estimation of plutonium recovery yield and uranium decontamination factor suggested the possibility in plutonium isotope measurement more than 100 fg. (author)

  3. Determination of traces of lithium in biological, environmental and metal samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Yang, J.Y.; Tseng, C.L.; Lo, J.M.; Yang, M.H.

    1985-01-01

    Lithium in environmental, biological and metal samples was determined by neutron activation analysis via the 6 Li(n,α)T and 16 O(T,n) 18 F reactions. The samples were converted to aqueous solutions either by dissolution or by digestion and their aliquots were irradiated in a nuclear reactor for 2 h. The irradiated sample solution, was placed in a ZrO 2 column on which the 18 F nuclide was adsorbed. Most of the coexisting nuclides 24 Na, 82 Br, 38 Cl, 64 Cu, etc. were separated by elution with pH 1proportional3 solution. The column was subjected to a Ge(Li) detector for γ-ray spectrometry. The lithium content in the sample was estimated from the 18 F activity obtained. The matrix effect can be eliminated by either strong dilution of the samples in aqueous medium or by the method of standard addition. Lithium can be determined with high precision and accuracy in sub-ppm samples. (orig.) [de

  4. Trace analysis of plutonium in environmental samples by resonance ionization mass spectroscopy (RIMS)

    International Nuclear Information System (INIS)

    Erdmann, N.; Herrmann, G.; Huber, G.; Koehler, S.; Kratz, J.V.; Mansel, A.; Nunnemann, M.; Passler, G.; Trautmann, N.; Waldek, A.

    1997-01-01

    Trace amounts of plutonium in the environment can be detected by resonance ionization mass spectroscopy (RIMS). An atomic beam of plutonium is produced after its chemical separation and deposition on a filament. The atoms are ionized by a three-step excitation using pulsed dye-lasers. The ions are mass-selectively detected in a time-of-flight (TOF) mass spectrometer. With this setup a detection limit of 1·10 6 atoms of plutonium has been achieved. Furthermore, the isotopic composition can be determined. Different samples, including soil from the Chernobyl area, IAEA-certified sediments from the Mururoa Atoll and urine, have been investigated. copyright 1997 American Institute of Physics

  5. Determination of trace elements in Tillandsia usneoides by neutron activation analysis for environmental biomonitoring

    International Nuclear Information System (INIS)

    Figueiredo, A.M.G.; Saiki, M.; Ticianelli, R.B.; Domingos, M.; Alves, E.S.; Markert, B.

    2001-01-01

    Neutron activation analysis was applied to the determination of the elements Al, As, Ba, Br, Cl, Co, Cr, Fe, K, Mg, Mn, Mo, Na, Rb, Sb, Sc, Ti, Th, V, Zn and the rare earths La, Ce, Nd, Sm, Eu, Tb and Yb in the epiphytic bromeliad Tillandsia usneoides. The samples were collected at an unpolluted area and exposed in different sites of the city of Sao Paulo, Brazil, and in a control site outside Sao Paulo. The results obtained showed an accumulation of Al, As, Cr, Fe, Mo, Sb, Ti, V and Zn elements in Tillandsia usneoides exposed in polluted sites, indicating a promising potential of this species as a biomonitor of air pollution in Sao Paulo. (author)

  6. Trace analysis of semiconductor materials

    CERN Document Server

    Cali, J Paul; Gordon, L

    1964-01-01

    Trace Analysis of Semiconductor Materials is a guidebook concerned with procedures of ultra-trace analysis. This book discusses six distinct techniques of trace analysis. These techniques are the most common and can be applied to various problems compared to other methods. Each of the four chapters basically includes an introduction to the principles and general statements. The theoretical basis for the technique involved is then briefly discussed. Practical applications of the techniques and the different instrumentations are explained. Then, the applications to trace analysis as pertaining

  7. Implementation trial of high performance trace analysis/environmental sampling (HPTA/ES) in uranium centrifuge enrichment plants

    International Nuclear Information System (INIS)

    Nackaerts, H.; Kloeckner, W.; Landresse, G.; MacLean, F.; Betti, M.; Forcina, V.; Hiernaut, T.; Tamborini, G.; Koch, L.; Schenkel, R.

    1999-01-01

    Field trials have demonstrated that the analysis of particles upon swipes obtained from inside nuclear installations provides clear signatures of past operations in that installation. This can offer a valuable tool for gaining assurance regarding the compliance with declared activities and the absence of undeclared activities (e.g. enrichment, reprocessing, and reactor operation) at such sites. This method, known as 'Environmental Sampling' (ES) or 'High Performance Trace Analysis' (HPTA) in EURATOM terminology, is at present being evaluated by the EURATOM Safeguards Directorate (ESD) in order to assess its possible use in nuclear installations within the European Union. It is expected that incorporation of HPTA/ES of sample collection and analysis into routine inspection activities will allow EURATOM to improve the effectiveness of safeguards in these installations and hopefully save inspection resources as well. The EURATOM Safeguards Directorate has therefore performed implementation trials involving the collection of particles by the so-called swipe sampling method in uranium centrifuge enrichment plants and hot cells in the European Union. These samples were subsequently analysed by the Joint Research Centre, Institute for Transuranium Elements (ITU) in Karlsruhe. Sampling points were chosen on the basis of the activities performed in the vicinity and by considering the possible ways through which particles are released, diffused and transported. The aim was to test the efficiency of the method as regards: the collection of enough representative material; the identification of a large enough number of uranium particles; the accurate measurement of the enrichment of the uranium particles found on the swipe; the representativity of the results in respect of past activities in the plant; the capability of detecting whether highly enriched uranium has been produced, used or occasionally transported in a location where low enriched uranium is routinely produced in

  8. Trace elements distribution in environmental compartments

    International Nuclear Information System (INIS)

    Queiroz, Juliana C. de; Peres, Sueli da Silva; Godoy, Maria Luiza D.P.

    2017-01-01

    Trace elements term defines the presence of low concentrations metals at environment. Some of them are considered biologically essential, as Co, Cu and Mn. Others can cause detriment to environment and human health, as Pb, Cd, Hg, As, Ti and U. A large number of them have radioactive isotopes, implying the evaluation of risks for human health should be done considering the precepts of environmental radiological protection. The ecosystem pollution with trace elements generates changes at the geochemistry cycle of these elements and in environmental quality. Soils have single characteristics when compared with another components of biosphere (air, water and biota), cause they introduce themselves not only as a drain towards contaminants, but also as natural buffer that control the transport of chemical elements and other substances for atmosphere, hydrosphere and biota. The main purpose of environmental monitoring program is to evaluate the levels of contaminants in the various compartments of the environment: natural or anthropogenic, and to assess the contribution of a potential contaminant source on the environment. Elemental Composition for the collected samples was determined by inductively coupled plasma mass spectroscopy. The main objective of this work was to evaluate the map baseline of concentration of interest trace elements in environmental samples of water, sediment and soil from Environmental Monitoring Program of Instituto de Radioprotecao e Dosimetria (IRD). The samples were analyzed using an inductively coupled plasma mass spectrometer (ICP-MS) at IRD. >From the knowledge of trace elements concentrations, could be evaluated the environmental quality parameters at the studied ecosystems. The data allowed evaluating some relevant aspects of the study of trace elements in soil and aquatic systems, with emphasis at the distribution, concentration and identification of main anthropic sources of contamination at environment. (author)

  9. Trace elements distribution in environmental compartments

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Juliana C. de; Peres, Sueli da Silva; Godoy, Maria Luiza D.P., E-mail: suelip@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-11-01

    Trace elements term defines the presence of low concentrations metals at environment. Some of them are considered biologically essential, as Co, Cu and Mn. Others can cause detriment to environment and human health, as Pb, Cd, Hg, As, Ti and U. A large number of them have radioactive isotopes, implying the evaluation of risks for human health should be done considering the precepts of environmental radiological protection. The ecosystem pollution with trace elements generates changes at the geochemistry cycle of these elements and in environmental quality. Soils have single characteristics when compared with another components of biosphere (air, water and biota), cause they introduce themselves not only as a drain towards contaminants, but also as natural buffer that control the transport of chemical elements and other substances for atmosphere, hydrosphere and biota. The main purpose of environmental monitoring program is to evaluate the levels of contaminants in the various compartments of the environment: natural or anthropogenic, and to assess the contribution of a potential contaminant source on the environment. Elemental Composition for the collected samples was determined by inductively coupled plasma mass spectroscopy. The main objective of this work was to evaluate the map baseline of concentration of interest trace elements in environmental samples of water, sediment and soil from Environmental Monitoring Program of Instituto de Radioprotecao e Dosimetria (IRD). The samples were analyzed using an inductively coupled plasma mass spectrometer (ICP-MS) at IRD. >From the knowledge of trace elements concentrations, could be evaluated the environmental quality parameters at the studied ecosystems. The data allowed evaluating some relevant aspects of the study of trace elements in soil and aquatic systems, with emphasis at the distribution, concentration and identification of main anthropic sources of contamination at environment. (author)

  10. Urban environmental geochemistry of trace metals

    International Nuclear Information System (INIS)

    Wong, Coby S.C.; Li Xiangdong; Thornton, Iain

    2006-01-01

    As the world's urban population continues to grow, it becomes increasingly imperative to understand the dynamic interactions between human activities and the urban environment. The development of urban environmental geochemistry has yielded a significant volume of scientific information about geochemical phenomena found uniquely in the urban environment, such as the distribution, dispersion, and geochemical characteristics of some toxic and potentially toxic trace metals. The aim of this paper is to provide an overview of the development of urban environmental geochemistry as a field of scientific study and highlight major transitions during the course of its development from its establishment to the major scientific interests in the field today. An extensive literature review is also conducted of trace metal contamination of the urban terrestrial environment, in particular of urban soils, in which the uniqueness of the urban environment and its influences on trace metal contamination are elaborated. Potential areas of future development in urban environmental geochemistry are identified and discussed. - Urban environmental geochemistry as a scientific discipline provides valuable information on trace metal contamination of the urban environment and its associated health effects

  11. Trace element content of human hair determined using neutron activation analysis as monitor of exposure effects to environmental metals

    International Nuclear Information System (INIS)

    Dutkiewicz, T.; Paprotny, W.; Sokolowska, D.; Kulka, E.; Woyciechowska, E.; Dybczynski, R.; Sterlinski, S.

    1978-01-01

    Determination of 17 trace elements, mainly metals, in small hair samples by neutron activation analysis was elaborated. The number of elements determined in one sample made it possible to assess quickly the exposure of human population in a given region. The hair samples after careful washing according to procedure elaborated previously were irradiated in high reactor neutron flux (approximately 10 14 n.cm -2 .s -1 ). The activities of samples were measured three times (for different decay times) by means of Ge(Li) gamma-ray spectrometer. A new version of the comparator technique, called a triple-single comparator method, was applied for quantitative analysis. The statistical methods used for planning of sampling and preliminary results on evaluation of analytical data are also described. (author)

  12. Neutron activation analysis for environmental trace element research determination of elemental composition of sediments in the Sea of Galillee, Israel

    Energy Technology Data Exchange (ETDEWEB)

    Lavi, N; Ne` eman, E; Brenner, S; Butenko, V [Tel Aviv Univ. (Israel). Medical School

    1996-12-01

    The aims of this work were to: a) demonstrate the effectiveness of instrumental neutron activation analysis for determining the background concentrations of trace elements in the sediments collected from the Sea of Gallile. b) determine the advantage factors for epithermal neutron irradiation. c) determine the contribution of silicon to the total {sup 28}Al activity by the {sup 28}Si(n,p){sup 28}Al reaction. c) check the validity of the method by determining the elemental content of U.S. NBS Standard Reference Material SRM-1633a (fly ash). d) calculate the average enrichment factors for the elements in sediments . e) determine the concentrations of the artificial radionuclides {sup 134}Cs, {sup 137}Cs and the naturally occurring radionuclides {sup 40}K, {sup 226}Ra and {sup 232}Th (authors).

  13. Trace Chemical Analysis Methodology

    Science.gov (United States)

    1980-04-01

    147 65 Modified DR/2 spectrophotometer face ........... ... 150 66 Colorimetric oil analysis field test kit ......... .. 152 67 Pictorial step...Assisted Pattern Recognitio Perhaps the most promising application of pattern recogntiontechniques for this research effort is the elucidation ".f the...large compartment on the spectrophotomer face . The screwdriver is used to adjust the zero adjust and light ad- just knobs, and the stainless steel

  14. Cork-based activated carbons as supported adsorbent materials for trace level analysis of ibuprofen and clofibric acid in environmental and biological matrices.

    Science.gov (United States)

    Neng, N R; Mestre, A S; Carvalho, A P; Nogueira, J M F

    2011-09-16

    In this contribution, powdered activated carbons (ACs) from cork waste were supported for bar adsorptive micro-extraction (BAμE), as novel adsorbent phases for the analysis of polar compounds. By combining this approach with liquid desorption followed by high performance liquid chromatography with diode array detection (BAμE(AC)-LD/HPLC-DAD), good analytical performance was achieved using clofibric acid (CLOF) and ibuprofen (IBU) model compounds in environmental and biological matrices. Assays performed on 30 mL water samples spiked at the 25.0 μg L(-1) level yielded recoveries around 80% for CLOF and 95% for IBU, under optimized experimental conditions. The ACs textural and surface chemistry properties were correlated with the results obtained. The analytical performance showed good precision (0.9922) from 1.0 to 600.0 μg L(-1). By using the standard addition methodology, the application of the present approach to environmental water and urine matrices allowed remarkable performance at the trace level. The proposed methodology proved to be a viable alternative for acidic pharmaceuticals analysis, showing to be easy to implement, reliable, sensitive and requiring low sample volume to monitor these priority compounds in environmental and biological matrices. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Environmental aspects of coal trace elements

    International Nuclear Information System (INIS)

    Swaine, D.J.

    1992-01-01

    The increasing use of coal, especially for power production, means that more attention is being given to environmental aspects. Some matters, for example, acid mine drainage, acid deposition and the relevance of coal-derived carbon and nitrogen oxides to the greenhouse effect are still being investigated in order to find methods of mitigation. However, much less attention has been given to possible untoward effects from trace elements in coal during mining, preparation and use. Occasional emotional outbursts, based on insufficient evidence, focus attention on arsenic, lead, cadmium, mercury and uranium. The best way to counter such claims is to provide proper information as a basis for more informed judgments. The comments contained in this article are mostly based on work done at the Commonwealth Science and Industrial Research Organization (CSIRO)

  16. Network application of PIXE trace element analysis

    International Nuclear Information System (INIS)

    Niizeki, T.; Kawasaki, K.; Hattori, T.

    2003-01-01

    Particle Induced X-ray Emission (PIXE) is a very sensitive analytical technique for determinations of trace elements. But the number of users is limited because there are not so much accelerators which can be used easily. On the other hand, PIXE is a typical machine analysis which can easily analyze automatically and make online data acquisition system. If there is useful online data handling system then PIXE analysis should be more useful for many persons. Therefore we develop to online PIXE facility at Tokyo Institute of Technology VdG laboratory and use it for environmental educations. (author)

  17. Application of environmental isotope tracing technology to geothermal geochemistry

    International Nuclear Information System (INIS)

    Shang Yingnan

    2006-01-01

    This paper reviews the recent application and development of environmental isotope tracing technology to geothermal geochemistry in the following aspects: gas isotopes (He, C) tracing of warm springs; H, O isotope tracing on the origin and cause of geothermal water, environmental isotope dating of geothermal water, and the advantage of excess parameter of deuterium (d) in geothermal research. The author also suggests that isotope method should combine with other geological methods to expand its advantage. (authors)

  18. Comparison of leaves of Nerium oleander collected the monitoring trace elements in environmental pollution in Rio de Janeiro and Campinas Cities using of synchrotron radiation fluorescence analysis

    International Nuclear Information System (INIS)

    Simabuco, Silvana M.; Ferreira Pinto, Jefferson; Dos Anjos, Marcelino J.

    1999-01-01

    These works describes the use of synchrotron radiation fluorescence analysis as a technique for monitoring trace elements in bio-indicators for environmental pollution control. The analyses were made on leaves of Nerium oleander collected in streets with different traffic flow in Rio de Janeiro and Campinas Cities, Brazil, with one sample from rural zone. Part of the leaves were cleaned with 0,1% v/v detergent in deionized water and than all were dry at 60o C until constant weight. The leaves were than cut in small pieces and submitted to a nitric digestion in a open system. The liquid residue was pre-concentrated with ammonium pirrrolidine dithiocarbamate and filtrated by vacuum pump in cellulose membrane. The measurement was made with a white beam of synchrotron radiation calibrated with thin film standards. The results indicate that same metals like Ti, V, Fe and Zn have major content in sample that came from places with high traffic flow even in leaves that have been washed. The levels of Mn, Co, Cu and Ni did not show significant difference between the samples. The Pb level also did not vary significantly what was expected because in Brazil the gasoline did not use plumb as a additive from many years. The results seems to indicate that the leaves from Nerium oleander absorb metals from the atmosphere and may be used as one environmental indicator

  19. Gene expression analysis of 4 biomarker candidates in Eisenia fetida exposed to an environmental metallic trace elements gradient: A microcosm study

    Energy Technology Data Exchange (ETDEWEB)

    Brulle, Franck; Lemiere, Sebastien [Univ Lille Nord de France, F-59000 Lille (France); LGCgE, Equipe Ecologie Numerique et Ecotoxicologie, Lille 1, F-59650 Villeneuve d' Ascq (France); Waterlot, Christophe; Douay, Francis [Univ Lille Nord de France, F-59000 Lille (France); LGCgE, Equipe Sols et Environnement, Groupe ISA, 48 boulevard Vauban, F-59046 Lille Cedex (France); Vandenbulcke, Franck, E-mail: franck.vandenbulcke@univ-lille1.fr [Univ Lille Nord de France, F-59000 Lille (France); LGCgE, Equipe Ecologie Numerique et Ecotoxicologie, Lille 1, F-59650 Villeneuve d' Ascq (France)

    2011-11-15

    Past activities of 2 smelters (Metaleurop Nord and Nyrstar) led to the accumulation of high amounts of Metal Trace Elements (TEs) in top soils of the Noyelles-Godault/Auby area, Northern France. Earthworms were exposed to polluted soils collected in this area to study and better understand the physiological changes, the mechanisms of acclimation, and detoxification resulting from TE exposure. Previously we have cloned and transcriptionally characterized potential biomarkers from immune cells of the ecotoxicologically important earthworm species Eisenia fetida exposed in vivo to TE-spiked standard soils. In the present study, analysis of expression kinetics of four candidate indicator genes (Cadmium-metallothionein, coactosin like protein, phytochelatin synthase and lysenin) was performed in E. fetida after microcosm exposures to natural soils exhibiting an environmental cadmium (Cd) gradient in a kinetic manner. TE body burdens were also measured. This microcosm study provided insights into: (1) the ability of the 4 tested genes to serve as expression biomarkers, (2) detoxification processes through the expression analysis of selected genes, and (3) influence of land uses on the response of potential biomarkers (gene expression or TE uptake). - Highlights: {yields} Expression biomarkers in animals exposed to Cadmium-contaminated field soils. {yields} Expression kinetics to test the ability of genes to serve as expression biomarkers. {yields} Study of detoxification processes through the expression analysis of selected genes.

  20. Covalent triazine framework-1 as adsorbent for inline solid phase extraction-high performance liquid chromatographic analysis of trace nitroimidazoles in porcine liver and environmental waters.

    Science.gov (United States)

    Zhong, Cheng; Chen, Beibei; He, Man; Hu, Bin

    2017-02-03

    In this study, covalent triazine framework-1 (CTF-1) was adopted as solid phase extraction (SPE) sorbents, and a method of SPE inline coupled with high performance liquid chromatography-ultraviolet (HPLC-UV) detection was developed for trace analysis of three nitroimidazolaes (including metronidazole, ronidazole and dimetridazole) in porcine liver and environmental water samples. CTF-1 has rich π-electron and N containing triazine, thus can form π-π interaction and intermolecular hydrogen bond with three target polar nitroimidazoles, resulting in high extraction efficiency (87%-98%). Besides, CTF-1 has large specific area, which benefits rapid mass transfer and low column pressure, leading to fast adsorption/desorption dynamics. Several parameters affecting inline SPE including pH, sample flow rate, sample volume, desorption reagents, elution flow rate, elution volume, and ionic strength were investigated. Under the optimal experimental conditions, the limits of detection (S/N=3) were found to be in the range of 0.11-0.13μg/L. The enrichment factors (EFs) ranged from 52 to 59 fold (theoretical EF was 60-fold). The relative standard deviations were in the range of 4.3-9.4% (n=7, c=1μg/L), and the linear range was 0.5-500μg/L for three target analytes. The sample throughput is 7/h. The proposed method was successfully applied to the analysis of nitroimidazoles in porcine liver and environmental water samples with good recoveries for the spiked samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. TraceContract: A Scala DSL for Trace Analysis

    Science.gov (United States)

    Barringer, Howard; Havelund, Klaus

    2011-01-01

    In this paper we describe TRACECONTRACT, an API for trace analysis, implemented in the SCALA programming language. We argue that for certain forms of trace analysis the best weapon is a high level programming language augmented with constructs for temporal reasoning. A trace is a sequence of events, which may for example be generated by a running program, instrumented appropriately to generate events. The API supports writing properties in a notation that combines an advanced form of data parameterized state machines with temporal logic. The implementation utilizes SCALA's support for defining internal Domain Specific Languages (DSLs). Furthermore SCALA's combination of object oriented and functional programming features, including partial functions and pattern matching, makes it an ideal host language for such an API.

  2. Ultra-Trace Analysis of Krypton-85

    International Nuclear Information System (INIS)

    Daerr, H.; Kalinowski, M.; Kohler, M.; Sahling, P.

    2010-01-01

    To strengthen the efficiency and effectiveness of nuclear safeguards for detecting undeclared nuclear material and activities we propose to use the radioactive krypton isotope Krypton-85 as a tracer for clandestine plutonium production. The main idea is to detect inexplicable atmospheric Kr85 concentration using the novel technology atom trap trace analysis (ATTA) in order to detect an undeclared reprocessing facility. The Additional Protocol (INFCIRC/540, 1997) establishes the possibility to take environmental samples. Krypton-85 has a combination of unique features which makes it an ideal tracer for plutonium separation activities anywhere in the world. It is always generated along with plutonium and 99.9% remains within the fuel cladding. Due to its half-life of 10.76 years, significant amounts of krypton-85 still remain in the spent fuel even after long cooling times. Krypton is not removed from the atmosphere by any processes like chemical reactions or wash-out. Furthermore, there are no other relevant sources of krypton-85 besides of reprocessing. The novel technology of atom trap trace analysis (ATTA) has been demonstrated by the physics group at Argonne National Laboratory in 1999. This is an ultra-sensitive trace analysis technique able to detect single krypton atoms. We are setting up an ATTA apparatus in our laboratory, which is designed to fulfill all requirements to detect clandestine plutonium production. Our goal is to determine Krypton-85 concentration of one liter samples of atmospheric air with an analysis time of 3 hours. This sample volume reduction is a significant step, since one liter can be taken as a grab sample by sucking it directly into pre-evacuated bottles at atmospheric pressure. The small samples size and the short analysis time of ATTA will make it possible to use krypton-85 as a tracer for clandestine plutonium production with routine operation. (author)

  3. Modified electrode voltammetric sensors for trace metals in environmental samples

    Directory of Open Access Journals (Sweden)

    Brett Christopher M.A.

    2000-01-01

    Full Text Available Nafion-modified mercury thin film electrodes have been investigated for the analysis of trace metals in environmental samples of waters and effluent by batch injection analysis with square wave anodic stripping voltammetry. The method, involving injection over the detector electrode of untreated samples of volume of the order of 50 microlitres has fast response, blocking and fouling of the electrode is minimum as shown by studies with surface-active components. Comparison is made between glassy carbon substrate electrodes and carbon fibre microelectrode array substrates, the latter leading to a small sensitivity enhancement. Application to analysis of river water and industrial effluent for labile zinc, cadmium, lead and copper ions is demonstrated in collected samples and after acid digestion.

  4. Diagnosing MOV problems using comparative trace analysis

    International Nuclear Information System (INIS)

    Leon, R.L.

    1992-01-01

    The paper presents the concept of comparative trace analysis and shows it to be very effective in diagnosing motor operated valve (MOV) problems. Comparative trace analysis is simply the process of interpreting simultaneously gathered traces, each presenting a different perspective on the same series of events. The opening and closing of a motor operated valve is such a series of events. The simultaneous traces are obtained using Liberty Technologies' Valve Operation Test and Evaluation System (VOTES)reg-sign. The traces include stem thrust, motor current, motor power factor, motor power, switch actuations, vibration in three different frequency bands, spring pack displacement, and spring pack force. Spare and auxiliary channels enable additional key parameters to be measured, such as differential pressure and stem displacement. Though not specifically illustrated in this paper, the VOTES system also provides for FFT analysis on all traces except switches

  5. Polyaniline/cyclodextrin composite coated stir bar sorptive extraction combined with high performance liquid chromatography-ultraviolet detection for the analysis of trace polychlorinated biphenyls in environmental waters.

    Science.gov (United States)

    Lei, Yun; He, Man; Chen, Beibei; Hu, Bin

    2016-04-01

    A novel polyaniline/α-cyclodextrin (PANI/α-CD) composite coated stir bar was prepared by sol-gel process for the analysis of polychlorinated biphenyls (PCBs) in this work. The preparation reproducibility of the PANI/α-CD-coated stir bar was good, with relative standard deviations (RSDs) ranging from 2.3% to 3.7% (n=7) and 2.0% to 3.8% (n=7) for bar to bar and batch to batch, respectively. Based on it, a novel method of PANI/α-CD-coated stir bar sorptive extraction (SBSE) followed by high performance liquid chromatography-ultraviolet (HPLC-UV) detection was developed for the determination of trace PCBs in environmental waters. To obtain the best extraction performance for target PCBs, several parameters affecting SBSE, such as extraction time, stirring rate, and ionic strength were investigated. Under optimal experimental conditions, the limits of detection (LODs) of the proposed method for seven PCBs were in the range of 0.048-0.22 μg/L, and the RSDs were 5.3-9.8% (n=7, c=1 μg/L). Enrichment factors (EFs) ranging from 39.8 to 68.4-fold (theoretical EF, 83.3-fold) for target analytes were achieved. The proposed method was successfully applied for the determination of seven target PCBs in Yangtze River water and East Lake water, and the recoveries were in the range of 73.0-120% for the spiked East Lake water samples and 82.7-121% for the spiked Yangtze River water samples, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Trace Element Analysis of Selenium

    International Nuclear Information System (INIS)

    Soliman, M.S.A.

    2010-01-01

    The present thesis divided into four chapters as follows:Chapter (1):This chapter contains an introduction on different oxidation states of organic and inorganic species for selenium in environmental and biological samples, the process for separation of selenium from these samples and the importance of selenium as a component for these samples. Also gives notes about the techniques which are used in the elemental analysis for selenium species and the detection limits for selenium in these techniques, selenium species in human body and the importance of these species in protecting the body from the different types of cancer and the sources of selenium in environmental samples (soil and water) and distribution levels of selenium in these samples.Chapter (2):This chapter is divided into two parts :The first part deals with the sample collection process for environmental samples (underground water, soil) and the wet digestion ( microwave digestion ) process of soil samples. It also contains the theory of work of the closed microwave digestion system.The second part contains detailed information concerning the theoretical considerations of the used analytical techniques. These techniques include Hydride generation - Atomic Absorption Spectrometer (HG-AAS), Inductively Coupled Plasma Mass Spectrometer (ICP-MS) and Neutron Activation Analysis (NAA).Chapter (3): This chapter includes the methods of sampling, sample preparation, and sample digesition. The measures of quality assurance are disscused in this chapter. It describes in details the closed microwave digestion technique and the analytical methods used in this study which are present in Central Laboratory for Elemental and Isotopic Analysis (CLEIA) and the Egypt Second Research Reactor (ETRR-2). The described techniques are Atomic Absorption Spectrometer (AAS 6 vario, Analytical Jena GmbH, Germany), JMS-PLASMAX2 Mass Spectrometer (ICP-MS) and the Egypt Second Research Reactor (NAA).

  7. Present and Future Challenges in Trace and Ultra-Trace Analysis

    International Nuclear Information System (INIS)

    Toulhoat, P.

    2005-01-01

    The analysis of trace and ultra-trace elements is continuously stimulating the progress in analytical chemistry. Environmental chemistry, radiochemistry, biology, health, agri-food are prescribers of trace analyses, with continuously increasing exigencies: lowering detection limits, lowering costs and analysis time, improving the quality of analytical information. Precise data about the chemical identity and chemical environment of analytes are now requested. Such pieces of information, beyond simple numerical data and confidence intervals, are necessary to understand studied systems, and to predict their evolution. From environmental contamination cases, one can envisage the various aspects of a problem, with for each of them its own exigencies and specificities in terms of analytical methods and approaches. The detection of traces and ultra-traces of actinides and fission products has been recently revisited and stimulates new technological developments (non proliferation issues, waste management). Data on their speciation in geological and biological media are essential for evaluating the safety of nuclear waste repositories. Various techniques are now used to determine speciation in liquid samples or on surfaces, with tremendous spatial resolutions or sensitivities. A new revolution in analytical chemistry is expected with the development of micro- or nano-analytical technologies. (author)

  8. Application of trace element analysis to determine trace element concentrations in the field of medicine

    International Nuclear Information System (INIS)

    Kasperek, K.; Feinendegen, L.E.

    1976-01-01

    Applied trace elements research in medicine requires a sensitive and efficient technique of trace elements analysis such as, e.g., neutron activation analysis. Essential trace elements act as stabilisators (iron in haem), structural elements (silicium in fibrous tissue), in hormones (iodine in thyroid hormone), in vitamins (cobalt in vitamin B 12), and in enzymes. Most of the essential trace elements act as coenzymes or in coenzymes or directly as metabolic catalysators. For example, selenium deficiency in PKU and maple syrup patients receiving dietary treatment can be detected by determining the selenium content of the serum, while low selenium values in the whole blood indicate liver cirrhosis. Acrodermatitis enteropathica can be diagnosed by determinig zinc in the serum, and pancreatic insufficiency by determining zinc in the pancreatic juice. Zinc also plays a part in disturbances of growth, in the healing of wounds, and in the insulin metabolism. Cobalt is important in some types of anaemia and in myocardiopathies. Trace elements are also necessary in the treatment of diseases, e.g. iron cobalt in some types of anaemia, and zinc in the delayed healing of wounds in the postoperative phase and in acrodermatitis enteropathica. Chromium is now being tested for the treatment of diabetes mellitus, and fluorides may be of interest in the treatment of osteoporosis. Finally, trace elements are important in the aetiology of acute poisoning, in nutrition, and in environmental protection. (orig./AK) [de

  9. Application of trace element analysis to determine trace element concentrations in the field of medicine. [Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Kasperek, K; Feinendegen, L E

    1976-01-01

    Applied trace elements research in medicine requires a sensitive and efficient technique of trace elements analysis, such as neutron activation analysis. Essential trace elements act as stabilizators (iron in haem), structural elements (silicon in fibrous tissue), in hormones (iodine in thyroid hormone), in vitamins (cobalt in vitamin B 12), and in enzymes. Most of the essential trace elements act as coenzymes or in coenzymes or directly as metabolic catalyzers. For example, selenium deficiency in PKU and maple syrup patients receiving dietary treatment can be detected by determining the selenium content of the serum, while low selenium values in the whole blood indicate liver cirrhosis. Acrodermatitis enteropathica can be diagnosed by determinig zinc in the serum, and pancreatic insufficiency by determining zinc in the pancreatic juice. Zinc also plays a part in disturbances of growth, in the healing of wounds, and in the insulin metabolism. Cobalt is important in some types of anaemia and in myocardiopathies. Trace elements are also necessary in the treatment of diseases, e.g. iron cobalt in some types of anaemia, and zinc in the delayed healing of wounds in the postoperative phase and in acrodermatitis enteropathica. Chromium is now being tested for the treatment of diabetes mellitus, and fluorides may be of interest in the treatment of osteoporosis. Finally, trace elements are important in the aetiology of acute poisoning, in nutrition, and in environmental protection.

  10. Trace amount analysis using spark mass spectrometry

    International Nuclear Information System (INIS)

    Stefani, Rene

    1975-01-01

    Characteristics of spark mass spectrometers (ion source, properties of the ion beam, ion optics, and performance) and their use in qualitative and quantitative analysis are described. This technique is very interesting for the semi-quantitative analysis of trace amounts, down to 10 -8 atoms. Examples of applications such as the analysis of high purity materials and non-conducting mineral samples, and determination of carbon and gas trace amounts are presented. (50 references) [fr

  11. Environmental Analysis

    Science.gov (United States)

    1980-01-01

    Burns & McDonnell Engineering's environmental control study is assisted by NASA's Computer Software Management and Information Center's programs in environmental analyses. Company is engaged primarily in design of such facilities as electrical utilities, industrial plants, wastewater treatment systems, dams and reservoirs and aviation installations. Company also conducts environmental engineering analyses and advises clients as to the environmental considerations of a particular construction project. Company makes use of many COSMIC computer programs which have allowed substantial savings.

  12. Trace analysis of total naphthenic acids in aqueous environmental matrices by liquid chromatography/mass spectrometry-quadrupole time of flight mass spectrometry direct injection.

    Science.gov (United States)

    Brunswick, Pamela; Shang, Dayue; van Aggelen, Graham; Hindle, Ralph; Hewitt, L Mark; Frank, Richard A; Haberl, Maxine; Kim, Marcus

    2015-07-31

    A rapid and sensitive liquid chromatography quadrupole time of flight method has been established for the determination of total naphthenic acid concentrations in aqueous samples. This is the first methodology that has been adopted for routine, high resolution, high throughput analysis of total naphthenic acids at trace levels in unprocessed samples. A calibration range from 0.02 to 1.0μgmL(-1) total Merichem naphthenic acids was validated and demonstrated excellent accuracy (97-111% recovery) and precision (1.9% RSD at 0.02μgmL(-1)). Quantitative validation was also demonstrated in a non-commercial oil sands process water (OSPW) acid extractable organics (AEOs) fraction containing a higher percentage of polycarboxylic acid isomers than the Merichem technical mix. The chromatographic method showed good calibration linearity of ≥0.999 RSQ to 0.005μgmL(-1) total naphthenic acids with a precision <3.1% RSD and a calculated detection limit of 0.0004μgmL(-1) employing Merichem technical mix reference material. The method is well suited to monitoring naturally occurring and industrially derived naphthenic acids (and other AEOs) present in surface and ground waters in the vicinity of mining developments. The advantage of the current method is its direct application to unprocessed environmental samples and to examine natural naphthenic acid isomer profiles. It is noted that where the isomer profile of samples differs from that of the reference material, results should be considered semi-quantitative due to the lack of matching isomer content. The fingerprint profile of naphthenic acids is known to be transitory during aging and the present method has the ability to adapt to monitoring of these changes in naphthenic acid content. The method's total ion scan approach allows for data previously collected to be examined retrospectively for specific analyte mass ions of interest. A list of potential naphthenic acid isomers that decrease in response with aging is proposed

  13. Environmental responsibilities of livestock feeding using trace mineral supplements

    Directory of Open Access Journals (Sweden)

    Daniel Brugger

    2015-09-01

    Full Text Available Trace elements are essential dietary components for livestock species. However, they also exhibit a strong toxic potential. Therefore, their fluxes through the animal organism are tightly regulated by a complex molecular machinery that controls the rate of absorption from the gut lumen as well as the amount of excretion via faeces, urine and products (e.g., milk in order to maintain an internal equilibrium. When supplemented in doses above the gross requirement trace elements accumulate in urine and faeces and, hence, manure. Thereby, trace element emissions represent a potential threat to the environment. This fact is of particular importance in regard to the widely distributed feeding practice of pharmacological zinc and copper doses for the purpose of performance enhancement. Adverse environmental effects have been described, like impairment of plant production, accumulation in edible animal products and the water supply chain as well as the correlation between increased trace element loads and antimicrobial resistance. In the light of discussions about reducing the allowed upper limits for trace element loads in feed and manure from livestock production in the European Union excessive dosing needs to be critically reconsidered. Moreover, the precision in trace element feeding has to be increased in order to avoid unnecessary supplementation and, thereby, heavy metal emissions from livestock production. Keywords: Trace element, Livestock, Homeostasis, Pharmacological supplementation, Accumulation, Environment

  14. Trace element analysis of human hair by neutron activation technique. Part of a coordinated programme on health-related environmental research, using nuclear techniques

    International Nuclear Information System (INIS)

    Kim, N.B.

    1982-10-01

    Hair mineral analysis was performed to measure population exposure to a number of environmental elemental pollutants. A total of 44 scalp hair samples from young Korean army recruits living in Seoul were analysed by INAA for 26 elements, including such elements of environmental health interest as As, Cd, and Hg. The levels reported were comparable with those reported in open literature. These results indicated that there was no evidence of any harmful exposure of the individuals studied to the metal pollutants monitored

  15. Trace element analysis of nail polishes

    International Nuclear Information System (INIS)

    Misra, G.; Mittal, V.K.; Sahota, H.S.

    1999-01-01

    Instrumental neutron activation analysis (INAA) technique was used to measure the concentrations of various trace elements in nail polishes of popular Indian and foreign brands. The aim of the present experiment was to see whether trace elements could distinguish nail polishes of different Indian and foreign brands from forensic point of view. It was found that cesium can act as a marker to differentiate foreign and Indian brands. (author)

  16. 5th colloquium on atomic spectrometric trace analysis

    International Nuclear Information System (INIS)

    Welz, B.

    1989-01-01

    This book deals with apparatus, use-oriented and theoretical aspects of trace analysis and spectroscopy. General articles are concerned with the analysis of environmentally relevant samples; a comparison of modern spectroscopic techniques, the coupling of hydride production, chromatography and spectrometry; chemical modifiers for graphite tube furnace atomic absorption spectroscopy (AAS), and possible applications of flow injection to atomic spectrometric trace analysis - one of the outstanding subjects of the colloquium. About one quarter of the 85 contributions deals with new techniques including flow injection. Other priority subjects are the theory and application of graphite tube furnace AAS, and a comparison between different dissolution methods and direct solid analysis. Medicine and toxicology, analysis of biological materials and environmentally relevant samples are in the foreground of use-oriented papers. (orig./BBR) [de

  17. Loess as an environmental archive of atmospheric trace element deposition

    Science.gov (United States)

    Blazina, T.; Winkel, L. H.

    2013-12-01

    Environmental archives such as ice cores, lake sediment cores, and peat cores have been used extensively to reconstruct past atmospheric deposition of trace elements. These records have provided information about how anthropogenic activities such as mining and fossil fuel combustion have disturbed the natural cycles of various atmospherically transported trace elements (e.g. Pb, Hg and Se). While these records are invaluable for tracing human impacts on such trace elements, they often provide limited information about the long term natural cycles of these elements. An assumption of these records is that the observed variations in trace element input, prior to any assumed anthropogenic perturbations, represent the full range of natural variations. However, records such as those mentioned above which extend back to a maximum of ~400kyr may not capture the potentially large variations of trace element input occurring over millions of years. Windblown loess sediments, often representing atmospheric deposition over time scales >1Ma, are the most widely distributed terrestrial sediments on Earth. These deposits have been used extensively to reconstruct continental climate variability throughout the Quaternary and late Neogene periods. In addition to being a valuable record of continental climate change, loess deposits may represent a long term environmental archive of atmospheric trace element deposition and may be combined with paleoclimate records to elucidate how fluctuations in climate have impacted the natural cycle of such elements. Our research uses the loess-paleosol deposits on the Chinese Loess Plateau (CLP) to quantify how atmospheric deposition of trace elements has fluctuated in central China over the past 6.8Ma. The CLP has been used extensively to reconstruct past changes of East Asian monsoon system (EAM). We present a suite of trace element concentration records (e.g. Pb, Hg, and Se) from the CLP which exemplifies how loess deposits can be used as an

  18. Spatial analysis of trace elements in a moss bio-monitoring data over France by accounting for source, protocol and environmental parameters.

    Science.gov (United States)

    Lequy, Emeline; Saby, Nicolas P A; Ilyin, Ilia; Bourin, Aude; Sauvage, Stéphane; Leblond, Sébastien

    2017-07-15

    Air pollution in trace elements (TE) remains a concern for public health in Europe. For this reasons, networks of air pollution concentrations or exposure are deployed, including a moss bio-monitoring programme in Europe. Spatial determinants of TE concentrations in mosses remain unclear. In this study, the French dataset of TE in mosses is analyzed by spatial autoregressive model to account for spatial structure of the data and several variables proven or suspected to affect TE concentrations in mosses. Such variables include source (atmospheric deposition and soil concentrations), protocol (sampling month, collector, and moss species), and environment (forest type and canopy density, distance to the coast or the highway, and elevation). Modeled atmospheric deposition was only available for Cd and Pb and was one of the main explanatory variables of the concentrations in mosses. Predicted soil content was also an important explanatory variable except for Cr, Ni, and Zn. However, the moss species was the main factor for all the studied TE. The other environmental variables affected differently the TE. In particular, the forest type and canopy density were important in most cases. These results stress the need for further research on the effect of the moss species on the capture and retention of TE, as well as for accounting for several variables and the spatial structure of the data in statistical analyses. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Analytical quality assessment and interpretation of the trace element data obtained in the frame of the IAEA Co-ordinated Research Programme on the significance of hair mineral analysis as a means for assessing internal body burdens of environmental pollutants

    International Nuclear Information System (INIS)

    Goeij, J.J.M. de; Blaauw, M.; Zegers, C.

    1993-01-01

    At the request of the IAEA, the authors have performed an assessment of the analytical quality and the interpretation of the trace element data obtained within the framework of the IAEA Co-ordinated Research Programme (CRP) on The Significance of Hair Mineral Analysis as a Means of Assessing Internal Body Burdens of Environmental Pollutants. In this CRP research groups from various countries participated, using different analytical procedures, based on NAA, XRF and AAS. Data have been collected for Zn, CU, Pb, Cd, As, Hg, and Se in male human hair, liver, kidney, lung, brain, and bone. The samples analyzed originated from China, Hungary, Bulgaria, Japan, the former GDR, Sweden and Norway. The analytical quality of the data has been assessed on basis of the calculated limits of quantitation per trace element determined, per tissue analyzed and per participant, as well as from the trace element values found for reference materials and ''blind'' materials. The analytical quality of the data differs widely, from generally good to reasonable (Zn, Cu, and Se) to generally inadequate to strongly inadequate (Pb, Cd, As, and Hg). 15 refs, 29 tabs

  20. Environmental lichenology: Biomonitoring of trace element air pollution

    International Nuclear Information System (INIS)

    Sukhodub, L.S.; Sulkio-Cleff, B.

    2001-01-01

    The review of application of lichens and mosses as biomonitors of air pollution have been presented. The neutron activation analysis and atomic absorption spectroscopy have been used for trace element content determination in lichens and mosses taken from different regions of Europe

  1. Monitoring environmental pollution of trace elements in tree-rings by synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    International Nuclear Information System (INIS)

    Moreira, Silvana; Vives, Ana Elisa S. de; Brienza, Sandra Maria B.; Medeiros, Jean Gabriel S.; Tomazello Filho, Mario; Zucchi, Orgheda L.A.D.; Nascimento Filho, Virgilio F.

    2005-01-01

    This paper aims to study the environmental pollution in the tree development, as a manner to evaluate its use as bioindicator in urban and country sides. The sample collecting was carry out in Piracicaba city, Sao Paulo State, that presents high level of environmental contamination of the water, soil and air, due industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. It was selected the Caesalpinia peltophoroides ('Sibipiruna') specie because its very used in urban arborization. It was employed the analytical technique named total reflection X-ray fluorescence (TXRF) to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was done in the Brazilian Synchrotron Light Laboratory, using a white beam for excitation and a Si(Li) detector for characteristic X-ray detection. It was quantified the P, K, Ca, Ti, Fe, Sr, Ba e Pb elements. (author)

  2. Monitoring environmental pollution of trace elements in tree-rings by synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo]. E-mail: Silvana@fec.unicamp.br; Vives, Ana Elisa S. de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Brienza, Sandra Maria B. [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil) Faculdade de Ciencias Matematicas, da Natureza e de Tecnologia da Informacao]. E-mail: sbrienza@unimep.br; Medeiros, Jean Gabriel S.; Tomazello Filho, Mario [Sao Paulo Univ., Piracicaba, SP (Brazil). Escola Superior de Agricultura Luiz de Queiroz]. E-mail: jeangm@esalq.usp.br; mtomazel@esalq.usp.br; Zucchi, Orgheda L.A.D. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: olzucchi@fcfrp.usp.br; Nascimento Filho, Virgilio F. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Instrumentacao Nuclear]. E-mail: virgilio@cena.usp.br

    2005-07-01

    This paper aims to study the environmental pollution in the tree development, as a manner to evaluate its use as bioindicator in urban and country sides. The sample collecting was carry out in Piracicaba city, Sao Paulo State, that presents high level of environmental contamination of the water, soil and air, due industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. It was selected the Caesalpinia peltophoroides ('Sibipiruna') specie because its very used in urban arborization. It was employed the analytical technique named total reflection X-ray fluorescence (TXRF) to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was done in the Brazilian Synchrotron Light Laboratory, using a white beam for excitation and a Si(Li) detector for characteristic X-ray detection. It was quantified the P, K, Ca, Ti, Fe, Sr, Ba e Pb elements. (author)

  3. Software for computerised analysis of cardiotocographic traces.

    Science.gov (United States)

    Romano, M; Bifulco, P; Ruffo, M; Improta, G; Clemente, F; Cesarelli, M

    2016-02-01

    Despite the widespread use of cardiotocography in foetal monitoring, the evaluation of foetal status suffers from a considerable inter and intra-observer variability. In order to overcome the main limitations of visual cardiotocographic assessment, computerised methods to analyse cardiotocographic recordings have been recently developed. In this study, a new software for automated analysis of foetal heart rate is presented. It allows an automatic procedure for measuring the most relevant parameters derivable from cardiotocographic traces. Simulated and real cardiotocographic traces were analysed to test software reliability. In artificial traces, we simulated a set number of events (accelerations, decelerations and contractions) to be recognised. In the case of real signals, instead, results of the computerised analysis were compared with the visual assessment performed by 18 expert clinicians and three performance indexes were computed to gain information about performances of the proposed software. The software showed preliminary performance we judged satisfactory in that the results matched completely the requirements, as proved by tests on artificial signals in which all simulated events were detected from the software. Performance indexes computed in comparison with obstetricians' evaluations are, on the contrary, not so satisfactory; in fact they led to obtain the following values of the statistical parameters: sensitivity equal to 93%, positive predictive value equal to 82% and accuracy equal to 77%. Very probably this arises from the high variability of trace annotation carried out by clinicians. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Speciation of trace elements in the environmental studies

    International Nuclear Information System (INIS)

    Reddy, A.V.R.

    2012-01-01

    Elements present at trace levels, often referred as trace elements, play an important role in the environment and in the functioning of life on our planet. Trace elements in environment present as free metal ions or incorporated into colloids or attached to particulate matter or exist in different physical and chemical forms. It is well established that some elements are highly toxic and some are essential, but can become toxic at higher doses. It is also now known that the forms of elements (speciation) and their amounts are more important than the chemical dose of the elements as their interaction depends on different species. For example, Cr(VI) ions are considered far more toxic than Cr(III), whereas As(III) is more toxic than As(V). Similarly, in the case of mercury, both methylmercury and inorganic mercury are toxic but they show different levels of toxicity. Thus the adverse effects depend on the nature of species of the elements and therefore speciation studies are of paramount importance in many areas like toxicology, environmental chemistry and geochemisty. In view of this, speciation studies is a challenge to analytical chemists as the measurement methodologies have to be carefully developed, validated and applied. The grand challenge is to obtain quality data ensuring traceability, as the data obtained will be used in modeling for predicting the environmental impacts. In this talk importance of speciation and challenges to environmental analytical chemists will be discussed along with the following three speciation studies on Cr, U and Hg which were carried out in our laboratories

  5. Trace and ultratrace level elemental and speciation analysis

    International Nuclear Information System (INIS)

    Arunachalam, J.

    2012-01-01

    Accurate determination of elements present at parts per million and billion levels in various matrices is a growing requirement in different fields. In environmental sciences various trace elements need to be analyzed so as establish the dispersal models of pollutants or the adequacy of effluent treatment prior to discharge into water bodies. The issues of bioaccumulation and magnification are important in aquatic systems. In nutrition and biochemistry one has to establish the bio-availability of essential and toxic elemental species as toxic elements prevent assimilation of essential elements. Fission and fusion technologies use a variety of structural materials requiring many trace elements to be present at levels strictly below the specified levels. Ultra-pure bulk semiconductor materials are required for fabrication devices. In metallurgy and materials sciences too, various trace elements are known to influence the properties. In the emerging fields like nanotechnology, it is necessary to understand the passage and accumulation of nano-particles inside the cells, through trace analysis. Many analytical techniques exist which can provide the concentration information in the bulk materials with good accuracy. They include ICP-AES, FAAS, and ICP-MS, which are solution based techniques. Direct solid state analytical techniques are Glow Discharge Mass Spectrometry (GDMS) and XRF. Accelerator based ion-beam analysis techniques can provide information on concentration and depth profiles of different elements in layered structures. Hyphenated techniques such as HPLC/lC-ICPMS, are helpful in identifying various chemical oxidation states in which a given element might be present in a matrix, which is termed as speciation analysis. This presentation will include the existing analytical competencies and the laboratory requirements for trace and ultra trace element elemental and speciation analyses and their applications. (author)

  6. Monitoring of the environmental pollution by trace element analysis in tree-rings using synchrotron radiation total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Sirito de Vives, Ana Elisa [School of Civil Engineering, Architecture and Urban Design Methodist University of Piracicaba, Rodovia Santa Barbara D' Oeste/Iracemapolis, km 01, 13450-000 Santa Barbara D' Oeste, SP (Brazil)]. E-mail: aesvives@unimep.br; Moreira, Silvana [State University of Campinas - UNICAMP/FEC (Brazil); Brienza, Sandra Maria Boscolo [School of Civil Engineering, Architecture and Urban Design Methodist University of Piracicaba, Rodovia Santa Barbara D' Oeste/Iracemapolis, km 01, 13450-000 Santa Barbara D' Oeste, SP (Brazil); Silva Medeiros, Jean Gabriel [University of Sao Paulo - USP/ ESALQ (Brazil); Tomazello Filho, Mario Tomazello [University of Sao Paulo - USP/ ESALQ (Brazil); Araujo Domingues Zucchi, Orgheda Luiza [University of Sao Paulo - USP/FCFRP (Brazil); Nascimento Filho, Virgilio Franco do [University of Sao Paulo - USP/CENA (Brazil)

    2006-11-15

    This paper aims to study the environmental pollution in the tree development, in order to evaluate its use as bioindicator in urban and country sides. The sample collection was carried out in Piracicaba city, Sao Paulo State, which presents high level of environmental contamination in water, soil and air, due to industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. The species Caesalpinia peltophoroides ('Sibipiruna') was selected because it is widely used in urban forestation. Synchrotron Radiation Total Reflection X-ray Fluorescence technique (SR-TXRF) was employed to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was performed in the Brazilian Synchrotron Light Source Laboratory, using a white beam for excitation and a Si(Li) detector for X-ray detection. In several samples, P, K, Ca, Ti, Fe, Sr, Ba and Pb were quantified. The K/Ca, K/P and Pb/Ca ratios were found to decrease towards the bark.

  7. Monitoring of the environmental pollution by trace element analysis in tree-rings using synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Sirito de Vives, Ana Elisa; Moreira, Silvana; Brienza, Sandra Maria Boscolo; Silva Medeiros, Jean Gabriel; Tomazello Filho, Mario Tomazello; Araujo Domingues Zucchi, Orgheda Luiza; Nascimento Filho, Virgilio Franco do

    2006-01-01

    This paper aims to study the environmental pollution in the tree development, in order to evaluate its use as bioindicator in urban and country sides. The sample collection was carried out in Piracicaba city, Sao Paulo State, which presents high level of environmental contamination in water, soil and air, due to industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. The species Caesalpinia peltophoroides ('Sibipiruna') was selected because it is widely used in urban forestation. Synchrotron Radiation Total Reflection X-ray Fluorescence technique (SR-TXRF) was employed to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was performed in the Brazilian Synchrotron Light Source Laboratory, using a white beam for excitation and a Si(Li) detector for X-ray detection. In several samples, P, K, Ca, Ti, Fe, Sr, Ba and Pb were quantified. The K/Ca, K/P and Pb/Ca ratios were found to decrease towards the bark

  8. Determination of artificial and natural radionuclides and others trace elements in environmental samples form Antarctica

    International Nuclear Information System (INIS)

    Schuch, L.A.; Godoy, J.M.; Nordemann, D.J.R.

    1994-01-01

    The results of the radioactive elements concentrations, determined by gamma spectrometry and the others trace elements determined by neutron activation analysis of several environmental samples (soils, marine sediments, algae mosses and lichens) in Comandante Ferraz Antartica Station are presented. The high concentrations of Cs-137 were found in lichens and mosses samples and the soils and sediments showed concentrations of natural radionuclides. (C.G.C.). 8 refs, 1 fig, 3 tabs

  9. Method development for trace and ultratrace analysis

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Method development, that is, selection of a mode of chromatography and the right column and mobile-phase combination for trace and ultratrace analysis, requires several main considerations. The method should be useful for resolving various trace and ultratrace components present in the sample. If the nature of these components is known, the choice of method may be straightforward, that is, a selection can be made from the following modes of HPLC: (1) adsorption chromatography; (2) normal-phase chromatography; (3) reversed-phase chromatography; (4) ion-pair chromatography; (5) ion-exchange chromatography; (6) ion chromatography. Unfortunately, the nature of all of the components is frequently unknown. However, several intelligent judgments can be made on the nature of impurities. This chapter deals with some basic approaches to mobile-phase selection and optimization. More detailed information may be found in basic texts. Techniques for separation of high-molecular-weight compounds (macromolecules) and chiral compounds may be found elsewhere. Mainly compounds with molecular weight lower than 2,000 are discussed here. 123 refs

  10. Development of a selective and pH-independent method for the analysis of ultra trace amounts of nitrite in environmental water samples after dispersive magnetic solid phase extraction by spectrofluorimetry.

    Science.gov (United States)

    Daneshvar Tarigh, Ghazale; Shemirani, Farzaneh

    2014-10-01

    This paper describes an innovative and rapidly dispersive magnetic solid phase extraction spectrofluorimetry (DMSPE-FL) method for the analysis of trace amounts of nitrite in some environmental water samples. The method includes derivatization of aqueous nitrite with 2, 3-diaminonaphthalene (DAN), analysis of highly fluorescent 2, 3-naphthotriazole (NAT) derivative using spectrofluorimetry after DSPME. The novelty of our method is based on forming NAT that was independent with the pH-responsive and was adsorbed on MMWCNT by hydrophobic attractions in both acidic and basic media. The extraction efficiency of the sorbent was investigated by extraction of nitrite. The optimum extraction conditions for NO2(-) were obtained as of extraction time, 1.5 min; 10mg sorbent from 160 mL of the sample solution, and elution with 1 mL of acetone/KOH. Under the optimal conditions, the calibration curves were obtained in the range of 0.1-80 µg L(-1) (R(2)=0.999) and LOD (S/N=3) was obtained in 34 ng L(-1). Relative standard deviations (RSD) were 0.6 % (five replicates at 5 μg L(-1)). In addition, the feasibility of the method was demonstrated with extraction and determination of nitrite from some real samples containing tap, mineral, sea, rain, snow and ground waters, with the recovery in standard addition to real matrix of 94-102 % and RSDs of 1.8-10.6%. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Multivariant analyses of trace element patterns for environmental tracking

    International Nuclear Information System (INIS)

    Jervis, R.E.; Ko, M.M.C.; Junliang Tian; Puling Liu

    1993-01-01

    Nuclear-based analytical techniques: INAA, PIXE and photon activation permit simultaneous multielemental determination of concentrations in environmental materials, which data are often found sufficiently precise and free of uncontrolled, random errors among the various elements such that the data sets can yield valuable information on elemental communality through multi-variant statistical 'factor' analysis. Characteristic factor patterns obtained in this way can provide clues to the likely sources in the environment of various components. Recent studies in three different environmental situations: solid waste incinerators , Chinese soils, and iron and steel industry, involving measurements of 30-35 elements, have yielded distinct elemental patterns or, environmental signatures, with factor loading coefficients ranging mostly in the ranges: 0.7-0.96. (author) 10 refs.; 2 figs.; 9 tabs

  12. Trace element analysis of soy sauce

    International Nuclear Information System (INIS)

    Tomita, Michio; Haruyama, Yoichi; Saito, Manabu

    1994-01-01

    Trace elements in soy sauce have been measured by means of in-air PIXE. Six kinds of trace elements were detected, such as Mu, Fe, Ni, Zn, Cu and Br. Concentrations of Mn, Fe, Zn and Br which were observed in all samples, have been determined. Each analyzed sample contained considerable amount of bromine about 160 ppm. (author)

  13. Environmental lichenology: Biomonitoring trace-element air pollution

    International Nuclear Information System (INIS)

    Sloof, J.E.

    1993-01-01

    Chapter 1 describes the possibilities to study trace-element air pollution in order to get insight in the character and element levels of such pollution. Chapter 2 describes two monitoring surveys using Parmelia sulcata Taylor on a national scale, in which spatial and temporal patterns of heavy metals were investigated. The surveys were carried out in 1982-1983 at 110 sampling sites and in 1986-1987 at 210 sampling sites. From these studies it was concluded that lichens are at least good qualitative biomonitors for atmospheric trace-element levels. Chapter 3 describes the response of lichens to the cesium-137 activity as a result of the Chernobyl accident, deposited by rainfall in the Netherlands. From this study it was concluded that lichens are good biomonitors for atmospheric cesium-137 activity too. Chapter 4 describes the application of factor analysis to a lichen data set from a monitoring survey on a national scale (1986-1987), for source apportionment. In Chapter 5 a field study is described on the contribution of a possible influence from the soil to element concentrations in Parmelia sulcata Taylor growing on trees in a an area with polluted soil. Chapter 6 describes a field study on the interchangeability of two tolerant lichen species (Parmelia sulcata Taylor and Lecanora conizaeoides Nyl.) in a polluted area. In Chapter 7 a field study is described in which the quantitative relationships between concentrations of cobalt, scandium and zinc in lichens and concentrations in air particulate matter and total deposition (wet and dry) were investigated. Chapter 8 describes a laboratory study on the kinetics of the uptake-and release of cadmium in a green algae species (Selenastrum capricornutum Printz), which is regarded to be representative for the algal symboint in the lichens used in this thesis. Chapter 9 presents the central conclusions of this thesis for the lichen species, elements and conditions under study. (orig./MG)

  14. Environmental lichenology: Biomonitoring trace-element air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Sloof, J E

    1993-09-27

    Chapter 1 describes the possibilities to study trace-element air pollution in order to get insight in the character and element levels of such pollution. Chapter 2 describes two monitoring surveys using Parmelia sulcata Taylor on a national scale, in which spatial and temporal patterns of heavy metals were investigated. The surveys were carried out in 1982-1983 at 110 sampling sites and in 1986-1987 at 210 sampling sites. From these studies it was concluded that lichens are at least good qualitative biomonitors for atmospheric trace-element levels. Chapter 3 describes the response of lichens to the cesium-137 activity as a result of the Chernobyl accident, deposited by rainfall in the Netherlands. From this study it was concluded that lichens are good biomonitors for atmospheric cesium-137 activity too. Chapter 4 describes the application of factor analysis to a lichen data set from a monitoring survey on a national scale (1986-1987), for source apportionment. In Chapter 5 a field study is described on the contribution of a possible influence from the soil to element concentrations in Parmelia sulcata Taylor growing on trees in a an area with polluted soil. Chapter 6 describes a field study on the interchangeability of two tolerant lichen species (Parmelia sulcata Taylor and Lecanora conizaeoides Nyl.) in a polluted area. In Chapter 7 a field study is described in which the quantitative relationships between concentrations of cobalt, scandium and zinc in lichens and concentrations in air particulate matter and total deposition (wet and dry) were investigated. Chapter 8 describes a laboratory study on the kinetics of the uptake-and release of cadmium in a green algae species (Selenastrum capricornutum Printz), which is regarded to be representative for the algal symboint in the lichens used in this thesis. Chapter 9 presents the central conclusions of this thesis for the lichen species, elements and conditions under study. (orig./MG).

  15. Matrix effect on the detection limit and accuracy in total reflection X-ray fluorescence analysis of trace elements in environmental and biological samples

    International Nuclear Information System (INIS)

    Karjou, J.

    2007-01-01

    The effect of matrix contents on the detection limit of total reflection X-ray fluorescence analysis was experimentally investigated using a set of multielement standard solutions (500 ng/mL of each element) in variable concentrations of NH 4 NO 3 . It was found that high matrix concentration, i.e. 0.1-10% NH 4 NO 3 , had a strong effect on the detection limits for all investigated elements, whereas no effect was observed at lower matrix concentration, i.e. 0-0.1% NH 4 NO 3 . The effect of soil and blood sample masses on the detection limit was also studied. The results showed decreasing the detection limit (in concentration unit, μg/g) with increasing the sample mass. However, the detection limit increased (in mass unit, ng) with increasing sample mass. The optimal blood sample mass of ca. 200 μg was sufficient to improve the detection limit of Se determination by total reflection X-ray fluorescence. The capability of total reflection X-ray fluorescence to analyze different kinds of samples was discussed with respect to the accuracy and detection limits based on certified and reference materials. Direct analysis of unknown water samples from several sources was also presented in this work

  16. Analysis of trace gases at ppb levels by proton transfer reaction mass spectrometry (PTR-MS)

    International Nuclear Information System (INIS)

    Lindinger, W.; Hansel, A.

    1996-01-01

    A proton transfer reaction mass spectrometry (PTR-MS) system has been developed which allows for on-line measurements of trace gas components with concentrations as low as 1 ppb. The method is based on reactions of H 3 O + ions, which perform non-dissociative proton transfer to most of the common organic trace constituents but do not react with any of the components present in clean air. Examples of medical information obtained by means of breath analysis, of environmental trace analysis, and examples in the field of food chemistry demonstrate the wide applicability of the method. (Authors)

  17. Automated computer analysis of plasma-streak traces from SCYLLAC

    International Nuclear Information System (INIS)

    Whitman, R.L.; Jahoda, F.C.; Kruger, R.P.

    1977-01-01

    An automated computer analysis technique that locates and references the approximate centroid of single- or dual-streak traces from the Los Alamos Scientific Laboratory SCYLLAC facility is described. The technique also determines the plasma-trace width over a limited self-adjusting region. The plasma traces are recorded with streak cameras on Polaroid film, then scanned and digitized for processing. The analysis technique uses scene segmentation to separate the plasma trace from a reference fiducial trace. The technique employs two methods of peak detection; one for the plasma trace and one for the fiducial trace. The width is obtained using an edge-detection, or slope, method. Timing data are derived from the intensity modulation of the fiducial trace. To smooth (despike) the output graphs showing the plasma-trace centroid and width, a technique of ''twicing'' developed by Tukey was employed. In addition, an interactive sorting algorithm allows retrieval of the centroid, width, and fiducial data from any test shot plasma for post analysis. As yet, only a limited set of sixteen plasma traces has been processed using this technique

  18. Automated computer analysis of plasma-streak traces from SCYLLAC

    International Nuclear Information System (INIS)

    Whiteman, R.L.; Jahoda, F.C.; Kruger, R.P.

    1977-11-01

    An automated computer analysis technique that locates and references the approximate centroid of single- or dual-streak traces from the Los Alamos Scientific Laboratory SCYLLAC facility is described. The technique also determines the plasma-trace width over a limited self-adjusting region. The plasma traces are recorded with streak cameras on Polaroid film, then scanned and digitized for processing. The analysis technique uses scene segmentation to separate the plasma trace from a reference fiducial trace. The technique employs two methods of peak detection; one for the plasma trace and one for the fiducial trace. The width is obtained using an edge-detection, or slope, method. Timing data are derived from the intensity modulation of the fiducial trace. To smooth (despike) the output graphs showing the plasma-trace centroid and width, a technique of ''twicing'' developed by Tukey was employed. In addition, an interactive sorting algorithm allows retrieval of the centroid, width, and fiducial data from any test shot plasma for post analysis. As yet, only a limited set of the plasma traces has been processed with this technique

  19. Trace element analysis: a diagnostic tool

    International Nuclear Information System (INIS)

    Qureshi, I.H.; Cheema, M.N.

    1976-09-01

    The human mody continuously assimilates a variety of elements from the environment, and the concentration of these elements in the blood is regulated by means of various homeostatic mechanisms. Some of the elements, though present in very small amounts, have highly specialized functions in initiating many biochemical reactions. These elements, known as essential trace elements, are closely related to human diseases since their deficiency or excess induces physiological changes. Many diseases such as hypertension, atherosclerosis, diabetes, etc., are related to an imbalance in trace element. The measurement of trace elements in body fluids and tissues can, therefore, be effectively employed for diagnostic tests

  20. TRACE Assessment for BWR ATWS Analysis

    International Nuclear Information System (INIS)

    Cheng, L.Y.; Diamond, D.; Cuadra, Arantxa; Raitses, Gilad; Aronson, Arnold

    2010-01-01

    A TRACE/PARCS input model has been developed in order to be able to analyze anticipated transients without scram (ATWS) in a boiling water reactor. The model is based on one developed previously for the Browns Ferry reactor for doing loss-of-coolant accident analysis. This model was updated by adding the control systems needed for ATWS and a core model using PARCS. The control systems were based on models previously developed for the TRAC-B code. The PARCS model is based on information (e.g., exposure and moderator density (void) history distributions) obtained from General Electric Hitachi and cross sections for GE14 fuel obtained from an independent source. The model is able to calculate an ATWS, initiated by the closure of main steam isolation valves, with recirculation pump trip, water level control, injection of borated water from the standby liquid control system and actuation of the automatic depressurization system. The model is not considered complete and recommendations are made on how it should be improved.

  1. Trace metals analysis in molybdenite mineral sample

    International Nuclear Information System (INIS)

    Tamrakar, Praveen Kumar; Pitre, K.S.

    2000-01-01

    DC polarography and other related techniques, viz., DPP and DPASV have been successfully used for the simultaneous determination of trace metals in molybdenite mineral sample. The polarograms and voltammograms of sample solution have been recorded in 0.1 M (NH 4 ) 2 tartrate supporting electrolyte at two different pH values i.e., 2.7±0.1 and 9.0±0.1. The results indicate the presence of Cu 2+ , Mo 6+ , Cd 2+ , Ni 2+ , In 3+ , Fe 3+ and W 6+ metal ions in the sample. For the determination of tungsten(VI), 11 M HCl has been used as supporting electrolyte. Tungsten(VI) produces a well defined wave/peak with E 1/2 /Ep=-0.42V/-0.48V vs SCE in 11 M HCl. The quantitative analysis by the method of standard addition shows the mineral sample to have the following composition, Cu 2+ ( 14.83), Mo 6+ (253.70), Cd 2+ (41.36), Ni 2+ (16.08), In 3+ (3.06), Fe 3+ (83.00)and W 6+ (4.14 )mg/g of the sample. Statistical treatment of the observed voltammetric data reveals high accuracy and good precision of determination. The observed voltammetric results are comparable with those obtained using AAS method. (author)

  2. Assessing the risks of trace elements in environmental materials under selected greenhouse vegetable production systems of China

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yong [Key Laboratory of Soil Environment and Pollution Remediation, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Huang, Biao, E-mail: bhuang@issas.ac.cn [Key Laboratory of Soil Environment and Pollution Remediation, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Hu, Wenyou [Key Laboratory of Soil Environment and Pollution Remediation, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Weindorf, David C.; Liu, Xiaoxiao [Department of Plant and Soil Science, Texas Tech University, Lubbock, TX (United States); Niedermann, Silvana [Department of Environmental Systems Science, Institute of Agricultural Science, ETH Zurich, 8092 Zurich (Switzerland)

    2014-02-01

    The risk assessment of trace elements of different environmental media in conventional and organic greenhouse vegetable production systems (CGVPS and OGVPS) can reveal the influence of different farming philosophy on the trace element accumulations and their effects on human health. These provide important basic data for the environmental protection and human health. This paper presents trace element accumulation characteristics of different land uses; reveals the difference of soil trace element accumulation both with and without consideration of background levels; compares the trace element uptake by main vegetables; and assesses the trace element risks of soils, vegetables, waters and agricultural inputs, using two selected greenhouse vegetable systems in Nanjing, China as examples. Results showed that greenhouse vegetable fields contained significant accumulations of Zn in CGVPS relative to rice–wheat rotation fields, open vegetable fields, and geochemical background levels, and this was the case for organic matter in OGVPS. The comparative analysis of the soil medium in two systems with consideration of geochemical background levels and evaluation of the geo-accumulation pollution index achieved a more reasonable comparison and accurate assessment relative to the direct comparison analysis and the evaluation of the Nemerow pollution index, respectively. According to the Chinese food safety standards and the value of the target hazard quotient or hazard index, trace element contents of vegetables were safe for local residents in both systems. However, the spatial distribution of the estimated hazard index for producers still presented certain specific hotspots which may cause potential risk for human health in CGVPS. The water was mainly influenced by nitrogen, especially for CGVPS, while the potential risk of Cd and Cu pollution came from sediments in OGVPS. The main inputs for trace elements were fertilizers which were relatively safe based on relevant

  3. Assessing the risks of trace elements in environmental materials under selected greenhouse vegetable production systems of China

    International Nuclear Information System (INIS)

    Chen, Yong; Huang, Biao; Hu, Wenyou; Weindorf, David C.; Liu, Xiaoxiao; Niedermann, Silvana

    2014-01-01

    The risk assessment of trace elements of different environmental media in conventional and organic greenhouse vegetable production systems (CGVPS and OGVPS) can reveal the influence of different farming philosophy on the trace element accumulations and their effects on human health. These provide important basic data for the environmental protection and human health. This paper presents trace element accumulation characteristics of different land uses; reveals the difference of soil trace element accumulation both with and without consideration of background levels; compares the trace element uptake by main vegetables; and assesses the trace element risks of soils, vegetables, waters and agricultural inputs, using two selected greenhouse vegetable systems in Nanjing, China as examples. Results showed that greenhouse vegetable fields contained significant accumulations of Zn in CGVPS relative to rice–wheat rotation fields, open vegetable fields, and geochemical background levels, and this was the case for organic matter in OGVPS. The comparative analysis of the soil medium in two systems with consideration of geochemical background levels and evaluation of the geo-accumulation pollution index achieved a more reasonable comparison and accurate assessment relative to the direct comparison analysis and the evaluation of the Nemerow pollution index, respectively. According to the Chinese food safety standards and the value of the target hazard quotient or hazard index, trace element contents of vegetables were safe for local residents in both systems. However, the spatial distribution of the estimated hazard index for producers still presented certain specific hotspots which may cause potential risk for human health in CGVPS. The water was mainly influenced by nitrogen, especially for CGVPS, while the potential risk of Cd and Cu pollution came from sediments in OGVPS. The main inputs for trace elements were fertilizers which were relatively safe based on relevant

  4. Development of methods for the neutron activation analysis to the determination of essential and toxic trace elements of biological and environmental samples: application of enzyme activity of raw hides

    International Nuclear Information System (INIS)

    Sipos, T.; Nagy, L.G.; Toeroek, G.; Kollar, J.

    1974-01-01

    Investigations on the post mortem enzymatic processes pointed out the fact, that significant deviations can be observed in the extent and in the results of the autolytic transformations occurring during the storage of raw hide. A neutron activation analysis procedure, based on a semiautomated radiochemical separation procedure and scintillation gamma spectrometry, was selected for the determination of some trace elements. Six trace elements, Cu, Mn, Zn, Au, As, and Cr, and one minor component,Br, were detected and/or determined in the concentration region of 0,1-10 3 ppM. According to preliminary investigations evaluated at the time being, concentration differences of some orders of magnitude were obtained for some trace elements: copper, zinc and manganese, whereas the concentration of bromine remained practically constant. These findings seem to correlate with large differences in appearance due to different enzyme activities in the raw hides

  5. Isotope dilution analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.; Lesny, J.; Korenova, Z.; Klas, J.; Klehr, E.H.

    1986-01-01

    Isotope dilution analysis has been used for the determination of several trace elements - especially metals - in a variety of environmental samples, including aerosols, water, soils, biological materials and geological materials. Variations of the basic concept include classical IDA, substoichiometric IDA, and more recently, sub-superequivalence IDA. Each variation has its advantages and limitations. A periodic chart has been used to identify those elements which have been measured in environmental samples using one or more of these methods. (author)

  6. Establishment of ultra trace nuclear material analysis system

    International Nuclear Information System (INIS)

    Song, Kyuseok; Jee, Kwangyong; Lee, Changheon

    2012-05-01

    Highly accurate and precise analysis of ultra trace nuclear materials contained in swipe samples and environmental samples is required to improve the national nuclear transparency and the international nuclear security. The objectives of the first stage of this project are to develop the techniques for bulk analysis of environmental samples and the elemental techniques for particle analysis using FT-TIMS. To accomplish the objectives, state-of-the-art analytical instruments were set up followed by the development of the techniques for screening of nuclear materials, chemical treatement, particle handling, isotopic measurements using TIMS and ICP-MS, and fabrication of uranium microparticles. The verifications of the developed techniques were carried out by measurement of reference materials, and by participation to interlaboratory comparison programs. In additon, the establishement of a quality management system and the performance of the analysis of QC samples for IAEA-NWAL qualification were carried out to obtain the international accreditation for the related analytical system. In this report, the results of research and developments, and the achievements to obtain the international accreditation were summarized

  7. Survey of reference materials. V. 2: Environmentally related reference materials for trace elements, nuclides and microcontaminants

    International Nuclear Information System (INIS)

    1996-05-01

    The present report presently contains over 250 reference materials with trace element and organic contaminant information on fuel, geological and mineral, anthropogenic disposal, soil reference and miscellaneous reference materials. Not included in the current report is information on most biological and environmental reference materials with trace element, stable isotope, radioisotope and organic contaminant information. 8 refs, tabs

  8. Instrumental trace element analysis of California market milk

    International Nuclear Information System (INIS)

    Ragaini, R.C.; Langhorst, A.L.; Ralston, H.R.; Heft, R.

    1975-01-01

    Trace element analysis for 15 elements (Zn, Na, Br, Rb, Sr, Mg, Al, Ca, Cl, I, K, Fe, Co, Se, Cs) was carried out on 32 samples of California market milk and 6 samples of Colorado milk in a pilot study of toxic and nutrient trace elements in the soil-forage-cow-milk food chain. The techniques of instrumental neutron activation analysis and x-ray fluorescence analysis are described. Sample collection, preparation, analysis, and data reduction procedures are discussed. The mean values and variations of trace element concentrations in milk are compared to data from other studies. (U.S.)

  9. Trace element analysis in soy sauce. 2

    International Nuclear Information System (INIS)

    Haruyama, Yoichi; Saito, Manabu; Tomita, Michio; Yoshida, Koji.

    1994-01-01

    Trace elements in four kinds of soybean and three kinds of salt have been measured by means of in-air PIXE. In soybeans, which were made in Japan, America, Canada and China, six kinds of trace elements were detected, such as Mn, Fe, Ni, Cu, Zn and Br. The concentration of these elements varied depending on the place they were made. American soybean showed characteristic feature compared with other soybeans. As to the bromine concentration, American soybean contains ten times as much as Japanese one. In salts Br and Sr were detected. (author)

  10. Trace element analysis in soy sauce

    International Nuclear Information System (INIS)

    Haruyama, Yoichi; Saito, Manabu; Tomiya, Michio

    1993-01-01

    Trace elements in soy sauce have been measured by means of in-air PIXE. Six kinds of trace elements were detected, such as Mn, Fe, Ni, Zn, Cu and Br. Concentrations of Mn, Fe, Zn and Br which were observed in all samples, have been determined. Each analyzed sample contained considerable amount of Br about 160 ppm. Comparison of Br content of the imported raw materials with those of the domestic ones suggested that the large amount of Br was the residual fumigation chemicals in the imported raw materials. (author)

  11. Trace elements in Australian opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Fardy, J.J.

    1994-01-01

    Neutron activation analysis was used to determine the concentration of trace elements in 42 samples of black, grey and white opals taken from a number of recognised Australian field. The results were evaluated to determine if a relationship exited between trace element content and opal colour. (author) 12 refs.; 12 figs.; 3 tabs

  12. Probing Trace-elements in Bitumen by Neutron Activation Analysis

    NARCIS (Netherlands)

    Nahar, S.N.; Schmets, A.J.M.; Scarpas, Athanasios

    Trace elements and their concentrations play an important role in both chemical and physical properties of bitumen. Instrumental Neutron Activation Analysis (INAA) has been applied to determine the concentration of trace elements in bitumen. This method requires irradiation of the material with

  13. Linking Environmental Magnetism to Geochemical Studies and Management of Trace Metals. Examples from Fluvial, Estuarine and Marine Systems

    Directory of Open Access Journals (Sweden)

    Michael Scoullos

    2014-07-01

    Full Text Available Among the diverse research fields and wide range of studies encompassed by environmental magnetism, the present work elaborates on critical aspects of the geochemistry of trace metals that emerged through years of original research in a variety of environmental compartments. This review aims at sharing the insights gained on (a tracing metal pollution sources; and (b identifying processes and transport pathways from sources to depositional environments. Case studies on the Elefsis Gulf (Greece and the Gulf of Lions (France demonstrate the potential of combined magnetic measurements and chemical analysis to trace pollution signals resulting from land-based sources and atmospheric deposition. Case studies on estuarine environments, namely the Louros, Acheloos, and Asopos Estuaries (Greece, address modes of trace metal behavior under the influence of different hydrological regimes and elucidate in situ processes within the transitional estuarine zone, that define their ultimate fate. As sources, transport pathways, and processes of trace metals are fundamental in environmental management assessments, the involvement of magnetic measurements in the policy cycle could facilitate the development and implementation of appropriate regulatory measures for the integrated management of river basins, coastal, and marine areas.

  14. Trace-element speciation and partitioning in environmental geochemistry and health

    Energy Technology Data Exchange (ETDEWEB)

    Farmer, J.G.; Gibson, M.J.; Lovell, M.A.

    1983-09-01

    Establishment of the chemical form and associations of trace elements is important in the scientifc and medical fields related to environmental geochemistry and health. Fundamental understanding of trace-element behavior, the realistic formulation of historical perspectives of trace-element contamination, an assessment of environmental transformation processes and a thorough appraisal of environment-related ill health and disease all depend on knowledge of the chemical speciation and partitioning of trace elements. These topics and the development of analytical speciation techniques and procedures are discussed with reference to trace-element studies in the Department of Forensic Medicine and Science, University of Glasgow, on lacustrine sediments and water, the atmosphere, soil and street dirt of an urban environment, and human biological fluids. 206 references, 4 figures.

  15. Biological and environmental reference materials for trace elements, nuclides and organic microcontaminants

    International Nuclear Information System (INIS)

    Cortes Toro, E.; Parr, R.M.; Clements, S.A.

    1990-01-01

    This report has been produced from a database on analytical reference materials of biological and environmental origin, which is maintained at the International Atomic Energy Agency. It is an updated version of an earlier report, published in 1985, which focussed mainly on reference materials for trace elements. In the present version of the report, reference materials for trace elements still constitute the major part of the data; however, information is also now included on a number of other selected analytes of relevance to IAEA programmes, i.e. radionuclides, stable isotopes and organic microcontaminants. The database presently contains 2,694 analyte values for 117 analytes in 116 biological and 77 environmental (non-biological) reference materials produced by 20 different suppliers. Additional information on the cost of the material, the unit size supplied, (weight or volume), and the minimum weight of material recommended for analysis is also provided (if available to the authors). It is expected that this report will help analysts to select the reference material that matches as closely as possible, with respect to matrix type and concentrations of the analytes of interest, the ''real'' samples that are to be analysed. Refs, 12 tabs

  16. TCP Packet Trace Analysis. M.S. Thesis

    Science.gov (United States)

    Shepard, Timothy J.

    1991-01-01

    Examination of a trace of packets collected from the network is often the only method available for diagnosing protocol performance problems in computer networks. This thesis explores the use of packet traces to diagnose performance problems of the transport protocol TCP. Unfortunately, manual examination of these traces can be so tedious that effective analysis is not possible. The primary contribution of this thesis is a graphical method of displaying the packet trace which greatly reduce, the tediousness of examining a packet trace. The graphical method is demonstrated by the examination of some packet traces of typical TCP connections. The performance of two different implementations of TCP sending data across a particular network path is compared. Traces many thousands of packets long are used to demonstrate how effectively the graphical method simplifies examination of long complicated traces. In the comparison of the two TCP implementations, the burstiness of the TCP transmitter appeared to be related to the achieved throughput. A method of quantifying this burstiness is presented and its possible relevance to understanding the performance of TCP is discussed.

  17. Environmental policy analysis

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    The Environmental Policy Analysis Program was established to improve the formation of energy development and environmental policies with due mutual regard for national environmental and energy development needs. As a separate office under the Assistant Secretary for Environment, the program is implemented by the Director and by Offices of Environmental Policy Analysis in the eight DOE multiprogram laboratories. The program provides the Assistant Secretary with information on alternatives for decision making and early warning of environmental problems and considerations that may affect energy policy decisions. The program is intended to be a continuing activity, with its scope determined progressively as issues are defined. During FY-1977 the program focused on information compilation on levels of Pu and other transuranic elements in soils that would render the area unsafe for unlimited use; the impact of water pollution control laws on energy technologies; an analysis of the comparative health risks associated with various energy technologies; and the cost and related impacts on the nuclear industry arising from changes in radiation standards during the past 15 years

  18. Trace elements in termites by PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimura, T. E-mail: tsuyoshi@termite.kuwri.kyoto-u.ac.jp; Kagemori, N.; Kawai, S.; Sera, K.; Futatsugawa, S

    2002-04-01

    Trace elements in a Japanese subterranean xylophagous termite, Coptotermes formosanus Shiraki, were analyzed by the PIXE method. The total amount of the 14 predominant elements out of 27 detected in an intact termite was higher in a soldier termite (23 000 {mu}g/g) than in a worker termite (10 000 {mu}g/g). A block of wood (Pinus densiflora Sieb. et Zucc.) for termite feed had a much lower concentration (3600 {mu}g/g) compared with that in an intact termite. This probably relates the functional bio-condensation and/or bio-recycling of trace elements in C. formosanus. When a termite was separated into three anatomical parts, head, degutted body and gut, the worker gut contained the highest total amount of the 14 predominant measured elements (31 000 {mu}g/g). This might be correlated with the higher activity of food digestion and energy production in the worker gut. Moreover, the mandible of the soldier head, with an exoskeleton that is intensely hardened, showed a preferential distribution of Mn and Fe. These results suggest that the characteristic localization of elements will be closely related to the functional role of the individual anatomical part of C. formosanus.

  19. Health Risk Assessment of Trace Metals in Various Environmental Media, Crops and Human Hair from a Mining Affected Area

    Directory of Open Access Journals (Sweden)

    Wushuang Xie

    2017-12-01

    Full Text Available Long term exposure to trace metals in various media is of great concern for people living in known pollution sources, such as mining and industrial activities. Health risk assessment and human hair analysis can provide important information for local environmental management. Information on distribution characteristics of trace metals in soil, water, sediment, air, local crops, and human hair from a typical mining area in southern China was collected. Results show there exists severely trace metal contamination in soil, sediment, and air. Arsenic and Pb contents in the local children’s hair are higher than the upper reference values, and the accumulation of residents’ hair trace metals shows great correlation with the ingestion and inhalation pathways. Arsenic contributes 52.27% and 58.51% to the total non-cancer risk of adults and children, respectively. The cancer risk of Cd in adults and children are 4.66 and 3.22 times higher than the safe level, respectively. Ingestion exposure pathway of trace metals largely contributes to the total non-cancer and cancer effect. The metals As, Cd, and Pb are major risk sources and pollutants that should be given priority for management, and ingestion pathway exposure to trace metals through soil and crops should be controlled.

  20. Applications of stable isotope analysis to atmospheric trace gas budgets

    Directory of Open Access Journals (Sweden)

    Brenninkmeijer C. A.M.

    2009-02-01

    Full Text Available Stable isotope analysis has become established as a useful method for tracing the budgets of atmospheric trace gases and even atmospheric oxygen. Several new developments are briefly discussed in a systematic way to give a practical guide to the scope of recent work. Emphasis is on applications and not on instrumental developments. Processes and reactions are less considered than applications to resolve trace gas budgets. Several new developments are promising and applications hitherto not considered to be possible may allow new uses.

  1. PIXE analysis of trace elements in cetacean teeth

    International Nuclear Information System (INIS)

    Mitani, Yoko; Arai, Nobuaki; Sakamoto, Wataru; Yoshida, Koji

    1997-01-01

    PIXE was adopted for analysis of trace elements in teeth of two species of cetaceans, sperm whale (Physeter microcephalus) and pantropical spotted dolphin (Stenella attenuata). The analyses were performed along with the growth layer of the teeth, which is formed annually, suitable for age determination. Mn, Fe, Cu, Zu and Sr were detected in the teeth of sperm whale and pantropical spotted dolphin. Among these trace elements, gradual increase was observed for Zn/Ca ratio in the sperm whale's teeth. (author)

  2. Trace elements in coloured opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1995-01-01

    Neutron activation analysis was used to determine the concentration of trace elements in 50 samples of orange, yellow, honey, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were evaluated to determine the relationship between trace elements content and opal colour. (author). 10 refs., 10 figs., 3 tabs

  3. The reliability of radiochemical and chemical trace analyses in environmental materials

    International Nuclear Information System (INIS)

    Heinonen, Jorma.

    1977-12-01

    After theoretically exploring the factors which influence the quality of analytical data as well as the means by which a sufficient quality can be assured and controlled, schemes of different kinds have been developed and applied in order to demonstrate the analytical quality assurance and control in practice. Methods have been developed for the determination of cesium, bromine and arsenic by neutron activation analysis at the natural ''background'' concentration level in environmental materials. The calibration of methods is described. The methods were also applied on practical routine analysis, the results of which are briefly reviewed. In the case of Ce the precision of a comprehensive calibration was found to vary between 5.2-9.2% as a relative standard deviation, which agrees well with the calculated statistical random error 5.7-8.7%. In the case of Br the method showed a reasonable precision, about 11% on the average, and accuracy. In employing the method to analyze died samples containing Br from 3 to 12 ppm a continuous control of precison was performed. The analysis of As demonstrates the many problems and difficulties associated with environmental analysis. In developing the final method four former intercomparison materials of IAEA were utilized in the calibration. The tests performed revealed a systematic error. In this case a scheme was developed for the continuous control of both precision and accuracy. The results of radiochemical analyses in environmental materials show a reliability somewhat better than that occuring in the determination of stable trace elements. According to a rough classification, 15% of the results of radiochemical analysis show excellent reliability, whereas 60% show a reliability adequate for certain purposes. The remaining 15% are excellent, 60% adequate for some purposes and 30% good-for-nothing. The reasons for often insufficient reliability of results are both organizational and technical. With reasonable effort and

  4. Derivative flame atomic absorption spectrometry and its application in trace analysis

    International Nuclear Information System (INIS)

    Sun, H. W.; Li, L. Q.

    2005-01-01

    Flame atomic absorption spectrometry is an accepted and widely used method for the determination of trace elements in a great variety of samples. But its sensitivity doesn't meet the demands of trace and ultra-trace analysis for some samples. The derivative signal processing technique, with a very high capability for enhancing sensitivity, was developed for flame atomic absorption spectrometry. The signal models of conventional flame atomic absorption spectrometry are described. The equations of derivative signals are established for flame atomic absorption spectrometry, flow injection atomic absorption spectrometry (FI-FAAS) and atom trapping flame atomic absorption spectrometry (AT-FAAS). The principle and performance of the derivative atomic absorption spectrometry are evaluated. The derivative technique based on determination of variation rate of signal intensity with time (dl/dt) is different from the derivative spectrophotometry based on determination of variation rate of signal intensity with wavelength (dl/dhλ). Derivative flame atomic absorption spectrometry has higher sensitivity, lower detection limits and better accuracy. It has been applied to the direct determination of trace elements without preconcentration. If the derivative technique was combined with several preconcentration techniques, the sensitivity would be enhanced further for ultra-trace analysis with good linearity. The applications of derivative flame atomic absorption spectroscopy are reviewed for trace element analysis in biological, pharmaceutical, environmental and food samples

  5. Using the ion microprobe mass analyser for trace element analysis

    International Nuclear Information System (INIS)

    Schilling, J.H.

    1978-01-01

    Most techniques for the analysis of trace elements are capable of determining the concentrations in a bulk sample or solution, but without reflecting their distribution. In a bulk analysis therefore elements which occur in high concentration in a few precipitates would still be considered trace elements even though their local concentration greatly exceed the normally accepted trace elements concentration limit. Anomalous distribution is also shown by an oxide layer, a few hundred Angstrom thick, on an aluminium sample. A low oxide concentration would be reported if it were included in the bulk analysis, which contradicts the high surface concentration. The importance of a knowledge of the trace element distribution is therefore demonstrated. Distributional trace element analysis can be carried out using the ion microprobe mass analyser (IMMA). Since the analytical technique used in this instrument, namely secondary ion mass spectrometry (SIMS), is not universally appreciated, the instrument and its features will be described briefly followed by a discussion of quantitative analysis and the related subjects of detection limit and sample consumption. Finally, a few examples of the use of the instrument are given

  6. Column: The Science of Digital Forensics: Analysis of Digital Traces

    Directory of Open Access Journals (Sweden)

    Fred Cohen

    2012-09-01

    Full Text Available In part 1 of this series (Cohen, 2011a, Analysis of digital traces is a foundational process by which the examiner, typically using computer software tools, comes to understand and answer basic questions regarding digital traces.“Input sequences to digital systems produce outputs and state changes as a function of the previous state. To the extent that the state or outputs produce stored and/or captured bit sequences, these form traces of the event sequences that caused them. Thus the definition of a trace may be stated as: "A set of bit sequences produced from the execution of a finite state machine."(see PDF for full column

  7. Field sampling of soil pore water to evaluate trace element mobility and associated environmental risk

    Energy Technology Data Exchange (ETDEWEB)

    Moreno-Jimenez, Eduardo, E-mail: eduardo.moreno@uam.es [Departamento de Quimica Agricola, Universidad Autonoma de Madrid, 28049 Madrid (Spain); Beesley, Luke [James Hutton Institute, Craigiebuckler, Aberdeen AB15 8QH (United Kingdom); Lepp, Nicholas W. [35, Victoria Road, Formby, Liverpool L37 7DH (United Kingdom); Dickinson, Nicholas M. [Department of Ecology, Lincoln University, Lincoln 7647, PO Box 84 (New Zealand); Hartley, William [School of Computing, Science and Engineering, University of Salford, Cockcroft Building, Salford, M5 4WT (United Kingdom); Clemente, Rafael [Dep. of Soil and Water Conservation and Organic Waste Management, CEBAS-CSIC, Campus Universitario de Espinardo, PO Box 164, 30100 Espinardo, Murcia (Spain)

    2011-10-15

    Monitoring soil pollution is a key aspect in sustainable management of contaminated land but there is often debate over what should be monitored to assess ecological risk. Soil pore water, containing the most labile pollutant fraction in soils, can be easily collected in situ offering a routine way to monitor this risk. We present a compilation of data on concentration of trace elements (As, Cd, Cu, Pb, and Zn) in soil pore water collected in field conditions from a range of polluted and non-polluted soils in Spain and the UK during single and repeated monitoring, and propose a simple eco-toxicity test using this media. Sufficient pore water could be extracted for analysis both under semi-arid and temperate conditions, and eco-toxicity comparisons could be effectively made between polluted and non-polluted soils. We propose that in-situ pore water extraction could enhance the realism of risk assessment at some contaminated sites. - Highlights: > In situ pore water sampling successfully evaluates trace elements mobility in soils. > Field sampling proved robust for different soils, sites and climatic regimes. > Measurements may be directly related to ecotoxicological assays. > Both short and long-term monitoring of polluted lands may be achieved. > This method complements other widely used assays for environmental risk assessment. - In situ pore water sampling from a wide variety of soils proves to be a beneficial application to monitor the stability of pollutants in soils and subsequent risk through mobility.

  8. Environmental risk analysis

    International Nuclear Information System (INIS)

    Lima-e-Silva, Pedro Paulo de

    1996-01-01

    The conventional Risk Analysis (RA) relates usually a certain undesired event frequency with its consequences. Such technique is used nowadays in Brazil to analyze accidents and their consequences strictly under the human approach, valuing loss of human equipment, human structures and human lives, without considering the damage caused to natural resources that keep life possible on Earth. This paradigm was developed primarily because of the Homo sapiens' lack of perception upon the natural web needed to sustain his own life. In reality, the Brazilian professionals responsible today for licensing, auditing and inspecting environmental aspects of human activities face huge difficulties in making technical specifications and procedures leading to acceptable levels of impact, furthermore considering the intrinsic difficulties to define those levels. Therefore, in Brazil the RA technique is a weak tool for licensing for many reasons, and of them are its short scope (only accident considerations) and wrong a paradigm (only human direct damages). A paper from the author about the former was already proposed to the 7th International Conference on Environmetrics, past July'96, USP-SP. This one discusses the extension of the risk analysis concept to take into account environmental consequences, transforming the conventional analysis into a broader methodology named here as Environmental Risk Analysis. (author)

  9. [Trace analysis of aristolochic acid A].

    Science.gov (United States)

    Liu, Yalin; Gao, Huimin; Wang, Zhimin; Zhang, Qiwei

    2010-12-01

    A HPLC method for limit detection of aristolochic acid A in the Chinese herbs containing aristolochic acid or suspected-containing aristolochic acid and their preparations was established. The samples were analyzed on an Alltima C18 column eluted with methanol-water-acetic acid (68:32:1.5) as the mobile phase. Flow rate was at 1.0 mL x min(-1) and the detection wavelength was at 390 nm. The calibration curve was linear over the range from 0.016 to 0.51 g (r = 0.9993) and LOD was 4 ng. The average recovery was 101.2% with RSD of 2.01%. The procedures of sample preparation were systematically investigated. The contents of aristolochic acid A in Radix et Rhizoma Asari bought from market or drugstore were fluctuated from 3.1 to 26.6 microg x g(-1) and 3 of 11 samples accorded with the quality requirement of current Chinese Pharmacopoeia. Among 15 batches samples of Chinese medicaments, only one sample was found to contain aristolochic acid A. The present investigation shows that the method is sensitive and repeatable and it could be used for the limit detection of aristolochic acid A in the Chinese herbal medicines containing trace amount of aristolochic acid A or suspected-containing aristolochic acid A and their preparations.

  10. Analysis of trace elements in opal using PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Ruth, E-mail: ruth.hinrichs@ufrgs.br [Instituto de Geociências, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil); Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Bertol, A.P.L. [Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Vasconcellos, M.A.Z. [Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Instituto de Física, UFRGS, Porto Alegre, RS (Brazil)

    2015-11-15

    Particle induced X-ray emission (PIXE) analysis is particularly important for the analysis of trace elements of precious samples, being one of the few methods to determine elements with ppm concentration that does not affect sample integrity. A PIXE methodology for trace element analysis in opal was developed. To avoid detector count saturation due to the high number of Si-Kα X-rays generated in the sample, several filters were employed to optimize the reduction of the Si-Kα signal, while maintaining acceptable intensities of the other relevant X-ray lines. Two proton beam energies were tested, to establish the signal to noise ratio in different X-ray energies. Spectra were fitted with the software GUPIX, using a matrix composition determined with electron beam excited energy dispersive X-ray spectrometry. Above the energy of the silicon X-ray, several trace elements were quantified.

  11. Environmental analysis support

    International Nuclear Information System (INIS)

    Miller, R.L.

    1994-01-01

    Activities in environmental analysis support included assistance to the Morgantown and Pittsburgh Energy Technology Centers (METC and PETC) in reviewing and preparing documents required by the National Environmental Policy Act (NEPA) for several projects selected for the Clean Coal Technology (CCT) Program. A key milestone was the completion for PETC of the final Environmental Impact Statement (EIS) for the Healy Clean Coal Project (HCCP) in Healy, Alaska. This work is notable because it is the first site-specific EIS completed for the CCT Program. Another important activity was the preparation for METC of a draft Environmental Assessment (EA) for the Externally Fired Combined Cycle (EFCC) Project in Warren, Pennsylvania. Also, the final EA was completed for the Gasification Product Improvement Facility (GPIF), a proposed project near Morgantown, West Virginia, which is part of METC's R ampersand D Program. In addition, ORNL staff members published a Technical Memorandum entitled open-quotes Potential Effects of Clean Coal Technologies on Acid Precipitation, Greenhouse Gases, and Solid Waste Disposalclose quotes which documents the findings of three open-quotes white papersclose quotes prepared for DOE/FE

  12. Analysis of trace elements in human hair by PIXE

    International Nuclear Information System (INIS)

    Baptista, G.B.; Montenegro, E.C.; Paschoa, A.S.; Barros Leite, C.V. de.

    1980-10-01

    The PIXE method was applied to the analysis of trace elements in scalp hair using two methods for target preparation. In the first method eigth hair strands each with nearly cylindrical geommetry and approximately the same diameter were selected and placed on an aluminum frame. In the second method a given mass of hair was dissolved with nitric acid and a known amount of strontium was added to the solution and dripped on a membrane filter using a micropipet. The results for the concentrations of trace elements in hair obtained by the two methods are compared and several aspects of the analysis is discussed. (Author) [pt

  13. X-ray fluorescence method for trace analysis and imaging

    International Nuclear Information System (INIS)

    Hayakawa, Shinjiro

    2000-01-01

    X-ray fluorescence analysis has a long history as conventional bulk elemental analysis with medium sensitivity. However, with the use of synchrotron radiation x-ray fluorescence method has become a unique analytical technique which can provide tace elemental information with the spatial resolution. To obtain quantitative information of trace elemental distribution by using the x-ray fluorescence method, theoretical description of x-ray fluorescence yield is described. Moreover, methods and instruments for trace characterization with a scanning x-ray microprobe are described. (author)

  14. Inorganic trace analysis by laser ionization mass spectrometry

    International Nuclear Information System (INIS)

    Becker, S.; Dietze, H.J.

    1991-01-01

    Among the different spectrometric techniques for trace analysis Laser Ionization Mass Spectrometry (LIMS) is well established as a trace analytic method with a wide coverage. In the LIMS the sample material is evaporated and ionized by means of a focused pulsed laser beam in a laser microplasma, which is formed in the spot area of the irradiated sample. All chemical elements in the sample materials are evaporated and ionized in the laser plasma. The formed ions are separated according to mass and energy by a time-of-flight, quadrupole or double focusing mass spectrometer. In this review the characteristics and analytical features, some recent developments, and applications of laser ionization mass spectrometry in inorganic trace analysis are described. (orig.)

  15. Laser ionization mass spectrometry in inorganic trace analysis

    International Nuclear Information System (INIS)

    Becker, J.S.; Dietze, H.J.

    1992-01-01

    Among the different spectrometric techniques for trace analysis Laser Ionization Mass Spectrometry (LIMS) is well established as a trace analytical method. With the LIMS technique the sample material is evaporated and ionized by means of a focused pulsed laser in a laser microplasma, which is formed in the spot area of the irradiated sample. All chemical elements in the sample materials are evaporated and ionized in the laser plasma. The ions formed are separated according to their mass and energy by a time-of-flight, quadrupole or double focusing mass spectrometer. In this review the characteristics and analytical features, some recent developments and applications of laser ionization mass spectrometry in inorganic trace analysis are described. (orig.)

  16. Liquid phase microextraction for the analysis of trace elements and their speciation

    International Nuclear Information System (INIS)

    Hu, Bin; He, Man; Chen, Beibei; Xia, Linbo

    2013-01-01

    Trace/ultra-trace elements and their speciation analysis in complex matrices usually require sample preparation procedures to achieve sample clean-up and analyte preconcentration. Sample preparation is often the bottleneck in trace elements and their speciation analysis which has a direct impact on accuracy, precision and limits of detection and is often the rate-determining step of the analytical process. Recent trends in sample preparation include miniaturization, automation, high-throughput performance and reduction in solvent/sample consumption and operation time. Liquid-phase microextraction (LPME) technique as a novel and promising alternative in sample preparation can meet these requirements and has become a very efficient sample preparation technique. This review updates the state of art of LPME for trace elements and their speciation analysis and discusses its promising prospects. The major thrust of the article highlights the applications of LPME including single-drop microextraction (SDME), hollow fiber-liquid phase microextraction (HF-LPME), dispersive liquid liquid microextraction (DLLME) and solidified floating organic drop microextraction (SFODME) to the fields of elemental and their speciation analysis by atomic spectrometry-based methods, especially inductively coupled plasma mass spectrometry. General and specific concepts, different extraction formats and characteristics of LPME are described and compared, along with examples of recent innovations and applications presented to demonstrate its potential for trace elements and their speciation analysis in biological and environmental fields. Moreover, the application potential and an outlook on the combination of LPME and atomic spectrometry-based techniques for inorganic analysis are commentated. - Highlights: • The state of art of LPME for trace elements and their speciation analysis is updated. • Different extraction formats of LPME are described. • The application potential and future

  17. Trace Elements in Dominant Species of the Fenghe River, China: Their Relations to Environmental Factors.

    Science.gov (United States)

    Yang, Yang; Zhou, Zhengchao; Bai, Yanying; Jiao, Wentao; Chen, Weiping

    2016-07-01

    The distribution of trace elements (TEs) in water, sediment, riparian soil and dominant plants was investigated in the Fenghe River, Northwestern China. The Fenghe River ecosystem was polluted with Cd, Cr, Hg and Pb. There was a high pollution risk in the midstream and downstream regions and the risk level for Cd was much higher than that of the other elements. The average values of bioconcentration coefficient for Cd and Zn were 2.21 and 1.75, respectively, indicating a large accumulation of Cd and Zn in the studied species. With broad ecological amplitudes, L. Levl. et Vant. Trin., and L. had the greatest TE concentrations in aboveground and belowground biomass of the studied species and were potential biomonitors or phytoremediators for the study area. Multivariate techniques including cluster analysis, correlation analysis, principal component analysis, and canonical correspondence analysis were used to analyze the relations between TE concentrations in plants and various environmental factors. The soil element concentration is the main factor determining the accumulation of TEs in plants. The co-release behavior of common pollutants and TEs drove the accumulation of Hg, Cd, and As in the studied plants. Significant enrichment of some elements in the Fenghe River has led to a decline in the biodiversity of plants. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  18. Multivariate statistical analysis of major and trace element data for ...

    African Journals Online (AJOL)

    Multivariate statistical analysis of major and trace element data for niobium exploration in the peralkaline granites of the anorogenic ring-complex province of Nigeria. PO Ogunleye, EC Ike, I Garba. Abstract. No Abstract Available Journal of Mining and Geology Vol.40(2) 2004: 107-117. Full Text: EMAIL FULL TEXT EMAIL ...

  19. Analysis of Trace Elements in South African Clinkers using Latent ...

    African Journals Online (AJOL)

    The trace element content of clinkers (and possibly of cements) can be used to identify the manufacturing factory. The Mg, Sr, Ba, Mn, Ti, Zr, Zn and V content of clinkers give detailed information for the determination of the origin of clinkers produced in different factories. However, for the analysis of such complex data there ...

  20. Possibilities of High Resolution Inductively Coupled Plasma Optical Emission Spectrometry in the Determination of Trace Elements in Environmental Materials

    Directory of Open Access Journals (Sweden)

    Nikolaya Velitchkova

    2013-01-01

    Full Text Available This paper presents new quantitative data for the spectral interferences obtained by high resolution 40.68 MHz radial viewing inductively coupled plasma optical emission spectrometry (HR-ICP-OES in the determination of Zn, Cd, Sb, Cu, Mn, Pb, Sn, Cr, U, and Ba in environmental materials in the presence of a complex matrix, containing Al, Ca, Fe, Mg, and Ti. The -concept for quantification of spectral interferences was used. The optimum line selection for trace analysis of a variety of multicomponent matrices requires the choice of prominent lines, which are free or negligibly influenced by line interference problems. The versatility of -concept as basic methodology was experimentally demonstrated in the determination of trace of elements in soil and drinking water. The detection limits are lower in comparison with corresponding threshold concentration levels for soil and drinking water in accordance with environmental regulations. This paper shows the possibilities of present day ICP-OES equipment in the direct determination of trace elements (without preconcentration of impurities in environmental samples.

  1. Analysis of trace metals in various brands of cigarettes

    International Nuclear Information System (INIS)

    Iqbal, M.

    1996-01-01

    The present work deals with the analysis of trace metals in various brands of cigarettes belonging to four different countries. In the present research seven trace elements have been determined spectrophotometrically by the use of suitable analytical reagent of the respective metal ions. The metals which has been analysed quantitatively in forty one brand of cigarettes are aluminium, copper, chromium, nickel, iron titanium and zinc. The concentration per cigarette of these metals are in tolerable range. The concentration of above mentioned metal ions is highest in Pakistani cigarettes tobacco while the concentration of nickel is highest in American cigarettes. (author) 221 refs

  2. Trace element analysis in rheumatoid arthritis under chrysotherapy

    International Nuclear Information System (INIS)

    Lecomte, R.; Paradis, P.; Monaro, S.; Barrette, M.; Lamoureux, G.; Menard, H.A.

    1981-01-01

    Proton induced X-ray emission (PIXE) analysis is used to measure trace element concentrations in blood serum from patients with rheumatoid arthritis. Initially trace element contaminations in blood-collecting and storing devices are determined. Then mean values and nyctemeral cycles are measured both in normal subjects and patients with rheumatoid arthritis and other similar pathologies. Abnormal concentrations of Cu and Zn and anomalies in the nyctemeral cycle are found in the patients. In the second phase of the project, the special case of chrysotherapeutically treated (gold salt treatment) rheumatoid arthritis patients is studied for extended periods of time (up to 53 weeks). (orig.)

  3. Applicability of analytical instrument in trace evidence analysis

    International Nuclear Information System (INIS)

    Sharma, Mukesh; Jha, Shailendra

    2014-01-01

    In the present paper, we explain the importance of the analytical instrument used in the field of forensic science for the analysis of the trace evidences collected from the scene of occurrence. The forensic scientist has to rely upon these instrumental analyses of trace amounts of materials like drugs, toxicological specimens, GSR, fibres, glass, paints, soil etc. Through this paper, reviews on these techniques which are extensively used in forensic sciences are reported. Our report summaries on the basis of analytical problem facing for a forensic expert and techniques employed to tackle them like XRD/XRF, inductively coupled plasma (ICP) techniques, Raman spectroscopy and microscopy (optical, GRIM, electron microscopy, TEM). (author)

  4. Computer compensation for NMR quantitative analysis of trace components

    International Nuclear Information System (INIS)

    Nakayama, T.; Fujiwara, Y.

    1981-01-01

    A computer program has been written that determines trace components and separates overlapping components in multicomponent NMR spectra. This program uses the Lorentzian curve as a theoretical curve of NMR spectra. The coefficients of the Lorentzian are determined by the method of least squares. Systematic errors such as baseline/phase distortion are compensated and random errors are smoothed by taking moving averages, so that there processes contribute substantially to decreasing the accumulation time of spectral data. The accuracy of quantitative analysis of trace components has been improved by two significant figures. This program was applied to determining the abundance of 13C and the saponification degree of PVA

  5. Trace elements in coloured opals using neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    McOrist, G.D.; Smallwood, A. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1996-12-31

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs.

  6. Trace elements in coloured opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1996-01-01

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs

  7. Trace elements in coloured opals using neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    McOrist, G D; Smallwood, A [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1997-12-31

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs.

  8. PIXE trace element analysis of a selection of wines

    International Nuclear Information System (INIS)

    Houdayer, A.; Hinrichsen, P.F.; Martin, J.P.; Belhadfa, A.

    1987-01-01

    The University of Montreal EN Tandem accelerator and a Si (Li) X-ray detector were used for a PIXE (Proton Induced X-ray emission) trace element analysis of a selection of wines. Quantitative measurements of the concentrations of the sixteen trace elements Na, Mg, Al, Si, P, S, Cl, K, Ca, Cr, Mn, Fe, Co, Cu, Zn, and Br were made. To optimize the sensitivity, spectra were recorded at 1.0 MeV proton energy for elements with Z 19. The absolute concentrations of the trace elements were determined by doping the samples of wine with 1000 ppm of vanadium for the 1.0 MeV bombardments, and 1000 ppm of yttrium for the 3.0 MeV irradiations. The targets were prepared by depositing a few microliters of the wine onto a Nuclepore filter

  9. Application of neutron activation analysis to the development of a monitoring system for trace metals in coastal waters

    International Nuclear Information System (INIS)

    Karbe, L.; Schnier, C.

    1976-03-01

    In view of the development of monitoring systems for trace metals in coastal waters, a research program has been started for a better understanding of interrelationships between input of trace metals, water chemistry, suspended matter, sediment and organisms. For multielement determinations neutron activation analysis has been chosen. Since environmental studies require the analysis of a large number of samples, the efficiency of the method is improved by automation of the acquisition and analysis of the γ-spectra from the Ge(Li) detectors. An automatic sample changer with counting device is described. First applications of the method in environmental research are presented. (orig.) [de

  10. Geochemistry of environmentally sensitive trace elements in Permian coals from the Huainan coalfield, Anhui, China

    Science.gov (United States)

    Chen, J.; Liu, Gaisheng; Jiang, M.; Chou, C.-L.; Li, H.; Wu, B.; Zheng, Lingyun; Jiang, D.

    2011-01-01

    To study the geochemical characteristics of 11 environmentally sensitive trace elements in the coals of the Permian Period from the Huainan coalfield, Anhui province, China, borehole samples of 336 coals, two partings, and four roof and floor mudstones were collected from mineable coal seams. Major elements and selected trace elements were determined by inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS), and hydride generation atomic absorption spectrometry (HAAS). The depositional environment, abundances, distribution, and modes of occurrence of trace elements were investigated. Results show that clay and carbonate minerals are the principal inorganic constituents in the coals. A lower deltaic plain, where fluvial channel systems developed successively, was the likely depositional environment of the Permian coals in the Huainan coalfield. All major elements have wider variation ranges than those of Chinese coals except for Mg and Fe. The contents of Cr, Co, Ni, and Se are higher than their averages for Chinese coals and world coals. Vertical variations of trace elements in different formations are not significant except for B and Ba. Certain roof and partings are distinctly higher in trace elements than underlying coal bench samples. The modes of occurrence of trace elements vary in different coal seams as a result of different coal-forming environments. Vanadium, Cr, and Th are associated with aluminosilicate minerals, Ba with carbonate minerals, and Cu, Zn, As, Se, and Pb mainly with sulfide minerals. ?? 2011 Elsevier B.V.

  11. An image analyzer system for the analysis of nuclear traces

    International Nuclear Information System (INIS)

    Cuapio O, A.

    1990-10-01

    Inside the project of nuclear traces and its application techniques to be applied in the detection of nuclear reactions of low section (non detectable by conventional methods), in the study of accidental and personal neutron dosemeters, and other but, are developed. All these studies are based on the fact that the charged particles leave latent traces of dielectric that if its are engraved with appropriate chemical solutions its are revealed until becoming visible to the optical microscope. From the analysis of the different trace forms, it is possible to obtain information of the characteristic parameters of the incident particles (charge, mass and energy). Of the density of traces it is possible to obtain information of the flow of the incident radiation and consequently of the received dose. For carry out this analysis has been designed and coupled different systems, that it has allowed the solution of diverse outlined problems. Notwithstanding it has been detected that to make but versatile this activity is necessary to have an Image Analyzer System that allow us to digitize, to process and to display the images with more rapidity. The present document, presents the proposal to carry out the acquisition of the necessary components for to assembling an Image Analyzing System, like support to the mentioned project. (Author)

  12. Tracing freshwater nitrate sources in pre-alpine groundwater catchments using environmental tracers

    Science.gov (United States)

    Stoewer, M. M.; Knöller, K.; Stumpp, C.

    2015-05-01

    Groundwater is one of the main resources for drinking water. Its quality is still threatened by the widespread contaminant nitrate (NO3-). In order to manage groundwater resources in a sustainable manner, we need to find options of lowering nitrate input. Particularly, a comprehensive knowledge of nitrate sources is required in areas which are important current and future drinking water reservoirs such as pre-alpine aquifers covered with permanent grassland. The objective of the present study was to identify major sources of nitrate in groundwater with low mean nitrate concentrations (8 ± 2 mg/L). To achieve the objective, we used environmental tracer approaches in four pre-alpine groundwater catchments. The stable isotope composition and tritium content of water were used to study the hydrogeology and transit times. Furthermore, nitrate stable isotope methods were applied to trace nitrogen from its sources to groundwater. The results of the nitrate isotope analysis showed that groundwater nitrate was derived from nitrification of a variety of ammonium sources such as atmospheric deposition, mineral and organic fertilizers and soil organic matter. A direct influence of mineral fertilizer, atmospheric deposition and sewage was excluded. Since temporal variation in stable isotopes of nitrate were detected only in surface water and locally at one groundwater monitoring well, aquifers appeared to be well mixed and influenced by a continuous nitrate input mainly from soil derived nitrogen. Hydrogeological analysis supported that the investigated aquifers were less vulnerable to rapid impacts due to long average transit times, ranging from 5 to 21 years. Our study revealed the importance of combining environmental tracer approaches and a comprehensive sampling campaign (local sources of nitrate, soil water, river water, and groundwater) to identify the nitrate sources in groundwater and its vulnerability. In future, the achieved results will help develop targeted

  13. Trace-element geochemistry of coal resource development related to environmental quality and health

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    This report assesses for decision makers and those involved in coal resource development the environmental and health impacts of trace-element effects arising from significant increases in the use of coal, unless unusual precautions are invoked. Increasing demands for energy and the pressing need for decreased dependence of the United States on imported oil require greater use of coal to meet the nation's energy needs during the next decade. If coal production and consumption are increased at a greatly accelerated rate, concern arises over the release, mobilization, transportation, distribution, and assimilation of certain trace elements, with possible adverse effects on the environment and human health. It is, therefore, important to understand their geochemical pathways from coal and rocks via air, water, and soil to plants, animals, and ultimately humans, and their relation to health and disease. To address this problem, the Panel on Trace Element Geochemistry of Coal Resource Development Related to Health (PECH) was established. Certain assumptions were made by the Panel to highlight the central issues of trace elements and health and to avoid unwarranted duplication of other studies. Based on the charge to the Panel and these assumptions, this report describes the amounts and distribution of trace elements related to the coal source; the various methods of coal extraction, preparation, transportation, and use; and the disposal or recycling of the remaining residues or wastes. The known or projected health effects are discussed at the end of each section.

  14. PIXE analysis for bioaccumulation studies of trace elements

    International Nuclear Information System (INIS)

    Iwata, Y.; Satoh, A.; Sasaki, Y.; Ito, R.; Kuramachi, K.

    2005-01-01

    Bioaccumulation by micro-alga in the ocean was simulated in nutritive seawater containing known amounts of trace metals, and the concentration factors for Fe, Zn and Cd were measured by PIXE. Trace transition metals in nearshore seawater were removed by Chelex-100. Then a culture solution was prepared by adding known amounts of trace metals and nutritive salts to the purified seawater. Marine micro-algae (Nannochloropsis sp., and Phaeodactylum sp.,) were purely cultured in the culture solution. An interested metal ion was added to the culture solution (0.01-5.0 mg/l). Alga in 10 ml of the culture solution was collected on a polycarbonate filter (pore size: 1.0 ) by suction filtration and subjected to 2.9 MeV proton bombardment. Na, Mg, Al, Si, P, S, Cl, K, Ca, Cr, Mn, Fe, Zn and Cd were simultaneously determined. PIXE multi-element analysis was possible using less than 1 mg of analytical sample. The quantity of the metal in the alga was increased in proportion to the concentration in the culture solution. The concentration factors for Zn, Fe and Cd were measured, e.g., 10200 ± 300 ml/g to Zn for Phaeodactylum. The trend of the affinity for the trace metals in the case of Nannochloropsis was Fe 3+ > Zn 2+ > Pb 2+ > Cd 2+ . (author)

  15. Separation of trace uranium from plutonium for subsequent analysis

    International Nuclear Information System (INIS)

    Marsh, S.F.

    1980-08-01

    Trace uranium quantities are separated from plutonium metal and plutonium oxide for subsequent analysis. Samples are dissolved in hydrobromic acid or a hydrobromic acid-hydrofluoric acid mixture. The U(VI)-halide complex is separated from nonsorbed Pu(III) on an anion exchange column using sequential washes of 9M HBr, a 0.1M HI-12M HCl mixture and 0.1M HCl

  16. Internal Versus External DSLs for Trace Analysis: Extended Abstract

    Science.gov (United States)

    Barringer, Howard; Havelund, Klaus

    2011-01-01

    This tutorial explores the design and implementation issues arising in the development of domain-specific languages for trace analysis. It introduces the audience to the general concepts underlying such special-purpose languages building upon the authors' own experiences in developing both external domain specific languages and systems, such as EAGLE, HAWK, RULER and LOGSCOPE, and the more recent internal domain-specific language and system TRACECONTRACT within the SCALA language.

  17. Preparation of hair and nail samples for trace element analysis

    International Nuclear Information System (INIS)

    Scoble, H.A.; Litman, R.

    1978-01-01

    The method of washing of human hair and nail samples is examined by neutron activation and γ-ray analysis. The amounts of Na, K, Br, Au, Zn, and La that are removed by successive washings determine the optimum number of washing for removing these trace elements as surface contaminants. A total solution contact time with the nails is 5 minutes, and leaching effcts are observed after 6 washings

  18. Audit and trace log management consolidation and analysis

    CERN Document Server

    Maier, Phillip Q

    2006-01-01

    As regulation and legislation evolve, the critical need for cost-effective and efficient IT audit and monitoring solutions will continue to grow. Audit and Trace Log Management: Consolidation and Analysis offers a comprehensive introduction and explanation of requirements and problem definition, and also delivers a multidimensional solution set with broad applicability across a wide range of organizations. Itprovidesa wealth of information in the form of processwalkthroughs. These include problem determination, requirements gathering,scope definition, risk assessment, compliance objectives,

  19. Neutron activation analysis of trace elements in IAEA reference materials

    International Nuclear Information System (INIS)

    Cheema, M.N.; Hasany, S.M.; Hanif, I.; Chaudhry, M.S.; Qureshi, I.H.

    1978-09-01

    Analytical Chemistry Group of Nuclear Chemistry Division at PINSTECH has been participating in IAEA Intercomparison programme of analytical quality control since 1972. So far fifteen samples of a variety of materials received from the Agency have been analyzed for different minor and trace elements. Mostly destructive and non-destructive neutron activation analysis techniques have been used for elemental analysis. In this report the description of the samples and the experimental procedures employed have been mentioned. The results of elemental analysis have been reported and compared with IAEA values which are based on the average computed from the results of different participating laboratories. (authors)

  20. PIXE analysis of caries related trace elements in tooth enamel

    International Nuclear Information System (INIS)

    Annegarn, H.J.; Jodaikin, A.; Cleaton-Jones, P.E.; Sellschop, J.P.F.; Madiba, C.C.P.; Bibby, D.; University of the Witwatersrand, Johannesburg

    1981-01-01

    PIXE analysis has been applied to a set of twenty human teeth to determine trace element concentration in enamel from areas suceptible to dental caries (mesial and distal contact points) and in areas less susceptible to the disease (buccal surface), with the aim of determining the possible roles of trace elements in the carious process. The samples were caries-free anterior incisors extracted for periodontal reasons from subjects 10-30 years of age. Prior to extraction of the sample teeth, a detailed dental history and examination was carried out in each individual. PIXE analysis, using a 3 MeV proton beam of 1 mm diameter, allowed the determination of Ca, Mn, Fe, Cu, Zn, Sr and Pb above detection limits. As demonstrated in this work, the enhanced sensitivity of PIXE analysis over electron microprobe analysis, and capability of localised surface analysis compared with the pooled samples require for neutron activation analysis, makes it a powerful and useful technique in dental analysis. (orig.)

  1. PIXE analysis of caries related trace elements in tooth enamel

    Energy Technology Data Exchange (ETDEWEB)

    Annegarn, H J; Jodaikin, A; Cleaton-Jones, P E; Sellschop, J P.F.; Madiba, C C.P.; Bibby, D [University of the Witwatersrand, Johannesburg (South Africa). Nuclear Physics Research Unit; University of the Witwatersrand, Johannesburg (South Africa). Dental Research Unit)

    1981-03-01

    PIXE analysis has been applied to a set of twenty human teeth to determine trace element concentration in enamel from areas suceptible to dental caries (mesial and distal contact points) and in areas less susceptible to the disease (buccal surface), with the aim of determining the possible roles of trace elements in the carious process. The samples were caries-free anterior incisors extracted for periodontal reasons from subjects 10-30 years of age. Prior to extraction of the sample teeth, a detailed dental history and examination was carried out in each individual. PIXE analysis, using a 3 MeV proton beam of 1 mm diameter, allowed the determination of Ca, Mn, Fe, Cu, Zn, Sr and Pb above detection limits. As demonstrated in this work, the enhanced sensitivity of PIXE analysis over electron microprobe analysis, and capability of localised surface analysis compared with the pooled samples require for neutron activation analysis, makes it a powerful and useful technique in dental analysis.

  2. Neutron activation analysis of trace elements in biological tissue

    Energy Technology Data Exchange (ETDEWEB)

    Velandia, J A; Perkons, A K

    1974-01-01

    Thermal Neutron Activation Analysis with Instrumental Ge(Li) Gamma Spectrometry was used to determine the amounts of more than 30 trace constituents in heart tissue of rats and kidney tissue of rabbits. The results were confirmed by a rapid ion-exchange group separation method in the initial stages of the experiments. The samples were exposed to thermal neutrons for periods between 3 minutes and 14 hours. Significant differences in the amounts and types of trace elements in the two different tissue types are apparent, however, are probably due to specific diets. Tables of relevant nuclear data, standard concentrations, radiochemical separation recoveries, and quantitative analytical results are presented. The ion-exchange group separation scheme and typical examples of the instrumental gamma ray spectra are shown. The techniques developed in this study are being used for a large scale constituent survey of various diseased and healthy human tissues.

  3. Trace elemental analysis of the aerosol particulates in northern Punjab

    International Nuclear Information System (INIS)

    Iqbal, M.Z.

    2002-01-01

    Trace elemental analysis of the aerosol particulates was studied in the atmosphere of Lahore, Faisalabad, Islamabad, Sheikhupura, Wah Cantt. And Khanispur. The amount of the aerosol particulates in the above mentioned areas was compared to the U.S. EPA maximum permissible limits. Scavenging mechanism of the aerosol particulates through precipitation was studied in the atmosphere of Lahore and Sheikhupura by using HPLC and ICP-AES techniques. The site distribution and morphological structure of the aerosol particulates was studied by using Scanning Electron Microscope model JSM-35CF. Trace elemental composition of the aerosol particulates in the atmosphere of the selected areas of Pakistan was carried out by using NAA. The elements thus studied were Ce, Yb, Se, Cr, Hf, Cs, Sc, Fe, Co, Eu, Sb, Mo, Ba, Zn, Hg, Br, Na, Gd, Sm, Nd and In while Pb and Cd were estimated by using ASS technique. (author)

  4. Neutron-activation analysis of trace elements in thyroids

    International Nuclear Information System (INIS)

    Boulyga, S.F.; Petri, H.; Kanash, N.V.; Malenchenko, A.F.

    1999-01-01

    Neutron activation analysis was used for routine measurement of trace elements in thyroids of inhabitants of Belarus as well as in thyroids of people operated for thyroid cancer. The method chosen allowed the analysis of 28 elements, among them essential and toxic ones, with a good accuracy. The results obtained showed significant differences in the elemental composition of thyroid from the different regions. The changes of elemental composition of thyroids of inhabitants of the Gomel region, where goiter is endemic, seem to be identical to those in the tumor tissue. (author)

  5. Study on correlation of trace elements in human hair and internal organs by nuclear methods. A final report of the co-ordinated research programme on the significance of hair mineral analysis as a means for assessing internal body burdens of environmental mineral pollutants. Final report for the period October 1985 - October 1988

    Energy Technology Data Exchange (ETDEWEB)

    Yuandi, Cheng [Academia Sinica, Shanghai, SH (China). Shanghai Inst. of Nuclear Research

    1988-12-31

    Autopsy samples of hair, kidney-cortex, liver and lung were analysed by radiochemical neutron activation analysis to determine the trace elements As, Cd, Hg, Cu and Zn, by instrumental neutron activation analysis to determine the trace elements Se, Na, Mg, Cl, Br, S, Cr, Co, and Rb and by PIXE to determine Fe, Ca and Mn. 15 refs, 22 figs, 10 tabs.

  6. Study on correlation of trace elements in human hair and internal organs by nuclear methods. A final report of the co-ordinated research programme on the significance of hair mineral analysis as a means for assessing internal body burdens of environmental mineral pollutants. Final report for the period October 1985 - October 1988

    International Nuclear Information System (INIS)

    Cheng Yuandi

    1988-01-01

    Autopsy samples of hair, kidney-cortex, liver and lung were analysed by radiochemical neutron activation analysis to determine the trace elements As, Cd, Hg, Cu and Zn, by instrumental neutron activation analysis to determine the trace elements Se, Na, Mg, Cl, Br, S, Cr, Co, and Rb and by PIXE to determine Fe, Ca and Mn. 15 refs, 22 figs, 10 tabs

  7. Assessment of both environmental cytotoxicity and trace metal pollution using Populus simonii Carr. as a bioindicator.

    Science.gov (United States)

    Sluchyk, Victor; Sluchyk, Iryna; Shyichuk, Alexander

    2014-10-01

    The level of environmental pollution in the city of Ivano-Frankivsk (Western Ukraine) has been assessed by means of roadside poplar trees as bioindicators. Dividable apical meristem cells of rudimentary leaves were quantitatively analysed for mitotic activity and distribution. Anaphases were further examined for chromosomal aberrations. Male catkins were also examined for sterile pollens. Accumulation of trace elements in vegetative buds was also evaluated in order to reveal source(s) of environmental pollution. Poplar trees growing in the urban environment proved to have increased chromosomal aberrations (up to 4-fold) and increased pollen sterility (up to 4-fold) as well as decreased mitotic activity (by factor 1.5) as compared to control sampling site. The biomarker data correlate moderately with increased (up to 4-fold) concentrations of Ni, Zn, Pb, Cd and Cu in vegetative tissues suggesting that probable cause of the environmental cytotoxicity may be vehicle emissions. The maximum increase in chromosomal aberrations (7-fold) and the minimum mitotic activity (half of the control one) were recorded in poplar trees growing in industrial suburb in vicinity of large cement production plant. Taking in mind insignificant bioaccumulation of trace elements in the industrial suburb, the high environmental toxicity has been ascribed to contamination in cement and asbestos particulates.

  8. Assurance and control of quality in trace element analysis

    International Nuclear Information System (INIS)

    Heinonen, J.

    1979-01-01

    The study demonstrates in practice the assurance and control of the quality of results from trace analysis in biological materials. The performance of three analytical methods is studied: one involving the determination of Cs and two the determination of As by neutron activation techniques in biological materials at the natural background level. In the case of Cs, the validity of the analytical procedure was investigated by the means available in the laboratory of the Institute and by utilizing the specific properties of the determinant. In the establishment and control of accuracy, the analysis of precision was essential. The investigation of the two different methods applied for the determination of arsenic demonstrates the many problems connected with trace analysis. For the control of accuracy a number of different kinds of reference materials (RMs) were used, namely four former intercomparison materials of the IAEA and two certified RMs of the NBS. The various tests performed revealed two different types of systematic errors. The scheme applied for the long-term surveillance of systematic and random errors is found to be suitable for the continuous control of quality of results from routine analysis. (author)

  9. Checking Flight Rules with TraceContract: Application of a Scala DSL for Trace Analysis

    Science.gov (United States)

    Barringer, Howard; Havelund, Klaus; Morris, Robert A.

    2011-01-01

    Typically during the design and development of a NASA space mission, rules and constraints are identified to help reduce reasons for failure during operations. These flight rules are usually captured in a set of indexed tables, containing rule descriptions, rationales for the rules, and other information. Flight rules can be part of manual operations procedures carried out by humans. However, they can also be automated, and either implemented as on-board monitors, or as ground based monitors that are part of a ground data system. In the case of automated flight rules, one considerable expense to be addressed for any mission is the extensive process by which system engineers express flight rules in prose, software developers translate these requirements into code, and then both experts verify that the resulting application is correct. This paper explores the potential benefits of using an internal Scala DSL for general trace analysis, named TRACECONTRACT, to write executable specifications of flight rules. TRACECONTRACT can generally be applied to analysis of for example log files or for monitoring executing systems online.

  10. Trace element fluxes in sediments of an environmentally impacted river from a coastal zone of Brazil.

    Science.gov (United States)

    da Silva, Yuri Jacques Agra Bezerra; Cantalice, José Ramon Barros; Singh, Vijay P; do Nascimento, Clístenes Williams Araújo; Piscoya, Victor Casimiro; Guerra, Sérgio M S

    2015-10-01

    Data regarding trace element concentrations and fluxes in suspended sediments and bedload are scarce. To fill this gap and meet the international need to include polluted rivers in future world estimation of trace element fluxes, this study aimed to determine the trace element fluxes in suspended sediment and bedload of an environmentally impacted river in Brazil. Water, suspended sediment, and bedload from both the upstream and the downstream cross sections were collected. To collect both the suspended sediment and water samples, we used the US DH-48. Bedload measurements were carried out using the US BLH 84 sampler. Concentrations of Cd, Cr, Cu, Fe, Mn, Ni, Pb, and Zn were determined by inductively coupled plasma (ICP-OES). As and Hg were determined by an atomic absorption spectrophotometer (AA-FIAS). The suspended sediments contributed more than 99 % of the trace element flux. By far Pb and to a less extent Zn at the downstream site represents major concerns. The yields of Pb and Zn in suspended sediments were 4.20 and 2.93 kg km(2) year(-1), respectively. These yields were higher than the values reported for Pb and Zn for Tuul River (highly impacted by mining activities), 1.60 and 1.30 kg km(2) year(-1), respectively, as well as the Pb yield (suspended + dissolved) to the sea of some Mediterranean rivers equal to 3.4 kg km(2) year(-1). Therefore, the highest flux and yield of Pb and Zn in Ipojuca River highlighted the importance to include medium and small rivers-often overlooked in global and regional studies-in the future estimation of world trace element fluxes in order to protect estuaries and coastal zones.

  11. TXRF analysis of trace metals in thin silicon nitride films

    International Nuclear Information System (INIS)

    Vereecke, G.; Arnauts, S.; Verstraeten, K.; Schaekers, M.; Heyrts, M.M.

    2000-01-01

    As critical dimensions of integrated circuits continue to decrease, high dielectric constant materials such as silicon nitride are being considered to replace silicon dioxide in capacitors and transistors. The achievement of low levels of metal contamination in these layers is critical for high performance and reliability. Existing methods of quantitative analysis of trace metals in silicon nitride require high amounts of sample (from about 0.1 to 1 g, compared to a mass of 0.2 mg for a 2 nm thick film on a 8'' silicon wafer), and involve digestion steps not applicable to films on wafers or non-standard techniques such as neutron activation analysis. A novel approach has recently been developed to analyze trace metals in thin films with analytical techniques currently used in the semiconductor industry. Sample preparation consists of three steps: (1) decomposition of the silicon nitride matrix by moist HF condensed at the wafer surface to form ammonium fluosilicate. (2) vaporization of the fluosilicate by a short heat treatment at 300 o C. (3) collection of contaminants by scanning the wafer surface with a solution droplet (VPD-DSC procedure). The determination of trace metals is performed by drying the droplet on the wafer and by analyzing the residue by TXRF, as it offers the advantages of multi-elemental analysis with no dilution of the sample. The lower limits of detection for metals in 2 nm thick films on 8'' silicon wafers range from about 10 to 200 ng/g. The present study will focus on the matrix effects and the possible loss of analyte associated with the evaporation of the fluosilicate salt, in relation with the accuracy and the reproducibility of the method. The benefits of using an internal standard will be assessed. Results will be presented from both model samples (ammonium fluoride contaminated with metallic salts) and real samples (silicon nitride films from a production tool). (author)

  12. ATTA - A new method of ultrasensitive isotope trace analysis

    International Nuclear Information System (INIS)

    Bailey, K.; Chen, C.Y.; Du, X.; Li, Y.M.; Lu, Z.-T.; O'Connor, T.P.; Young, L.

    2000-01-01

    A new method of ultrasensitive isotope trace analysis has been developed. This method, based on the technique of laser manipulation of neutral atoms, has been used to count individual 85 Kr and 81 Kr atoms present in a natural krypton gas sample with isotopic abundances in the range of 10 -11 and 10 -13 , respectively. This method is free of contamination from other isotopes and elements and can be applied to various different isotope tracers for a wide range of applications. The demonstrated detection efficiency is 1x10 -7 . System improvements could increase the efficiency by many orders of magnitude

  13. Evaluation of NAA laboratory results in inter-comparison on determination of trace elements in food and environmental samples

    International Nuclear Information System (INIS)

    Diah Dwiana Lestiani; Syukria Kurniawati; Natalia Adventini

    2012-01-01

    Inter-comparison program is a good tool for improving quality and to enhance the accuracy and precision of the analytical techniques. By participating in this program, laboratories could demonstrate their capability and ensuring the quality of analysis results generated by analytical laboratories. The Neutron Activation Analysis (NAA) laboratory at National Nuclear Energy Agency of Indonesia (BATAN), Nuclear Technology Center for Materials and Radiometry-PTNBR laboratory participated in inter-comparison tests organized by NAA working group. Inter-comparison BATAN 2009 was the third inter-laboratory analysis test within that project. The participating laboratories were asked to analyze for trace elements using neutron activation analysis as the primary technique. Three materials were distributed to the participants representing foodstuff, and environmental material samples. Samples were irradiated in rabbit facility of G.A. Siwabessy reactor with neutron flux ~ 10 13 n.cm -2 .s -1 , and counted with HPGe detector of gamma spectrometry. Several trace elements in these samples were detected. The accuracy and precision evaluation based on International Atomic Energy Agency (IAEA) criteria was applied. In this paper the PTNBR NAA laboratory results is evaluated. (author)

  14. ICP-MS applications for the analysis of geological materials and environmental samples

    International Nuclear Information System (INIS)

    Bendl, J.

    1997-01-01

    This work deals with applications of inductively coupled plasma - mass spectrometry applications for the analysis of geological materials and environmental samples. There are instrumentation, calibration, alternatives of sample introduction, interferences, trace elements analysis, rare earth elements and uranium and thorium, precious metals, isotopic analysis and environmental analysis discussed

  15. Adsorptive stripping voltammetric determination of trace amounts of lead in environmental water samples with complicated matrix

    Directory of Open Access Journals (Sweden)

    Grabarczyk M.

    2013-04-01

    Full Text Available A sensitive, simple and fast adsorptive stripping voltammetric procedure for trace determination of lead in environmental water samples has been developed. The method is based on adsorptive accumulation of the Pb(II-cupferron complex onto a hanging mercury drop electrode, followed by the reduction of the adsorbed species by a voltammetric scan using differential pulse modulation. The interference from surface active substances was eliminated by adsorption of interferents onto an Amberlite XAD-16 resin. Optimumconditions for removing the surfactants by mixing the analysed sample with resin were evaluated. The accuracy of the method was tested by analyzing certified reference material (SPS-WW1 Waste Water.

  16. Solid-phase extraction and determination of trace elements in environmental samples using naphthalene adsorbent

    International Nuclear Information System (INIS)

    Pourreza, N.

    2004-01-01

    Naphthalene co-precipitated with quaternary ammonium salt such as tetraoctyl ammonium bromide and methyltrioctyl ammonium chloride have been used as adsorbent for solid phase extraction of metal ions such as Hg, Cd and Fe. The metal ions are retained on the adsorbent in a column as their complexes with suitable ligands and eluted by an eluent before instrumental measurements. The optimization of the procedures for solid phase extraction and consequent determination of trace elements and application to environmental samples especially water samples will be discussed. (author)

  17. XRF analysis of portland cement for major and trace elements

    International Nuclear Information System (INIS)

    Abdunnabi, A. R.

    2012-12-01

    Libyan portland cement produced in several factories around the country, in Lip tis, Zoltan, Souq-Elkamis, Dernah and El-Fatach, were analyzed for quantitative major and trace elements and mineral content, which were compered with those imported from Spain, Romania, Cyprus, and Egypt. X-ray fluorescence spectro X lab 2000 spectrometer equipped with Rh-and X-ray tube was used for the analysis of various samples. The detector Si(Li) with a resolution of 148 eV at Mn K-a=5.9 keV facilitates the determination of a wide range of elements from sodium to uranium, with a detection limit at sub levels. Cement samples in the powder form were analyzed using the pellet-technique. The pellets were prepared by mixing 4g of the cement powder with 0.9 g of binder (HWC) and pressed at high pressure. A ful analysis including, background counting, matrix correction and all relevant corrections were achieved automatically by XLAB 2000 software package. For major and trace elements X RF results were higher for most of the elements than those analyzed with atomic absorption spectrometry. The mineral content showed that Libyan cement is comparable to the imported ones, also the Libyan cement meets the requirements of the international specifications of the portland cement. (Author)

  18. Activation analysis in a multitechnique study of trace element imbalances in age-related neurological diseases

    International Nuclear Information System (INIS)

    Ehmann, W.D.; Ding, X.X.; Khare, S.S.; Lovell, M.A.; Ni, B.F.; Tandon, L.; Vance, D.E.; Wenstrup, D.E.

    1993-01-01

    It has been suggested that several age-related neurological diseases such as Alzheimer's disease and amyotrophic lateral sclerosis may be related to environmental toxins. Bulk sample multielemental analyses by INAA alone are not adequate to define the role of trace elements in these diseases. A multitechnique approach has been developed that incorporates 14 MeV, instrumental reactor, radiochemical, and pre-irradiation chemical neutron activation analysis, together with laser microprobe mass spectrometry. The analytical scheme is able to provide bulk or protein normalized elemental concentrations, as well as microstructural, cellular, and subcellular localization information. (author) 21 refs.; 3 figs.; 3 tabs

  19. Environmental conditions analysis program

    International Nuclear Information System (INIS)

    Holten, J.

    1991-01-01

    The PC-based program discussed in this paper has the capability of determining the steady state temperatures of environmental zones (rooms). A program overview will be provided along with examples of formula use. Required input and output from the program will also be discussed. Specific application of plant monitored temperatures and utilization of this program will be offered. The presentation will show how the program can project individual room temperature profiles without continual temperature monitoring of equipment. A discussion will also be provided for the application of the program generated data. Evaluations of anticipated or planned plant modifications and the use of the subject program will also be covered

  20. Current status of JAERI program on development of ultra-trace-analytical technology for safeguards environmental samples

    International Nuclear Information System (INIS)

    Adachi, T.; Usuda, S.; Watanabe, K.

    2001-01-01

    Full text: In order to contribute to the strengthened safeguards system based on the Program 93+2 of the IAEA, Japan Atomic Energy Research Institute (JAERI) is developing analytical technology for ultra-trace amounts of nuclear materials in environmental samples, and constructed the CLEAR facility (Clean Laboratory for Environmental Analysis and Research) for this purpose. The development of the technology is carried out, at existing laboratories for time being, in the following fields: screening, bulk analysis and particle analysis. The screening aims at estimating the amounts of nuclear materials in environmental samples to be introduced into the clean rooms, and is the first step to avoid cross-contamination among the samples and contamination of the clean rooms themselves. In addition to ordinary radiation spectrometry, Compton suppression technique was applied to low energy γ- and X-ray measurements, and sufficient reduction in background level has been demonstrated. Another technique in examination is imaging-plate method, which is a kind of autoradiography and suitable for determination of radioactive-particle distribution in the samples as well as for semiquantitative determination. As for the bulk analysis, the efforts are temporally made on uranium in swipe samples. Preliminary examination for optimization of sample pre-treatment conditions is in progress. At present, ashing by low-temperature-plasma method gives better results than high-temperature ashing or acid leaching. For the isotopic ratio measurement, instrumental performance of inductively-coupled plasma mass spectrometry (ICP-MS) are mainly examined because sample preparation for ICP-MS is simpler than that for thermal ionization mass spectrometry (TIMS). It was found by our measurement that the swipe material (TexWipe TX304, usually used by IAEA) contains un-negligible uranium blank with large deviation (2-6 ng/sheet). This would introduce significant uncertainty in the trace analysis. JAERI

  1. Neutron activation analysis for bulk and trace elements in urine

    International Nuclear Information System (INIS)

    Cornelis, R.; Speecke, A.; Hoste, J.

    1975-01-01

    Problems in sampling urine for trace element analysis by neutron activation are systematically examined. Collection, storage, sample preparation and contamination hazards during irradiation are studied in detail. Three different sizes of urine samples are prepared for analysis, depending on the concentration and nuclear properties of the elements, and suitable multielement doped urine standards are used. As, Br, Ca, Cl, Co, Cr, Cs, Cu, Hg, I, K, Mg, Mn, Na, Rb, Se and Zn are determined. The extreme care given to sample collection, use of ''ultra-clean'' vials, and work in a dust-free room allows consistent values to be obtained over long periods of time. A literature review of the amounts of forty elements present in urine per day is also given

  2. Study of trace impurities in heroin by neutron activation analysis

    International Nuclear Information System (INIS)

    Zhang, Z.Y.; Yang, J.H.; Ouyang, H.; Li, Z.J.; Chai, Z.F.; Zhu, J.; Xi'an JiaoTong Univ., Shaanxi; Zhao, J.Z.; Yu, Z.S.; Wang, J.

    2004-01-01

    Sixty-two heroin samples were analyzed for their contents of 15 trace elements (Au, Ba, Br, Ca, Ce, Co, Cr, Fe, La, Na, Sb, Sc, Sm, Th, and Zn) by neutron activation analysis (NAA). Large variations of elemental concentrations between samples were found to possess statistical significance. Of all the elements calcium was the most abundant element, followed by zinc and sodium. The concentrations of Au, Ce, Co, La, Sb, Sc, Sm, and Th in all the samples were below 1 μg x g -1 . Classification of these heroin samples was achieved by the application of hierarchical cluster analysis. The results show that NAA can provide useful information on the origin of the illicit drugs. (author)

  3. Neutron activation analysis of trace elements in foodstuffs

    International Nuclear Information System (INIS)

    Schelenz, R.; Fischer, E.

    1976-05-01

    A neutron activation method for multielement determination in biological material was developed. The individual steps of the method include radiochemical processing as well as nondestructive techniques. In order to develop a high resolution gamma spectrometric method the indispensable assumptions were the application of Ge(Li)-semiconductor detectors, multi-channel pulse height analyzers and the use of electronic data evaluation with mini-computers for the automatic evaluation of complex gamma spectra. After radiochemical separation (RNAA) 33 elements can be determined in biological materials and by application of nondestructive, purely instrumental techniques (INAA) 25 elements. The time required for the analysis of 33 elements can be determined in biological materials and by application of nondestructive, purely instrumental techniques (INAA) 25 elements. The time required for the analysis of 33 elements is 4 days. The neutron activation method is used routinely for the determination of trace elements in foodstuffs and in the field of nutrition research. (orig.) [de

  4. Contribution to improving extreme trace analysis for platinum in biotic and environmentally relevant materials; Beitrag zur Verbesserung der extremen Spurenanalytik der Platinmetalle in biotischen und umweltrelevanten Materialien (VPT 01)

    Energy Technology Data Exchange (ETDEWEB)

    Alt, F [Institut fuer Spektrochemie und Angewandte Spektroskopie, Dortmund (Germany)

    1998-12-31

    The declared aim of the present project was to develop reliable and powerful detection methods for platinum metals and in particular platinum. Special emphasis was placed on practicability and transferability to other applications. This meant that the sample preparation techniques and detection methods employed would have to be available to other laboratories without significant prior investment costs. On the hand the analysis method had to meet very exacting requirements because platinum metals are among the rarest substances contained in the Earth`s crust (1x10-7%-10x10-7%) and the element quantities and concentrations to be detected are in range of 10-12g or 10-9g/kg(L), respectively. These levels are approximately three orders of magnitude smaller than those relevant to other environmentally consequential elements (e.g., lead, cadmium). [Deutsch] Die Entwicklung zuverlaessiger und nachweisstarker Bestimmungsmethoden fuer Platinmetalle, besonders Platin, war das erklaerte Ziel dieses Vorhabens. Besonderer Wert sollte allerdings auch auf die Durchfuehrbarkeit und Uebertragbarkeit fuer andere Anwender gelegt werden. Dies bedeutete, dass moeglichst nur Probenvorbereitungstechniken und Bestimmungsmethoden integriert werden sollten, die ohne grosse Investitionskosten auch anderen Laboratorien zur Verfuegung stehen. Andererseits werden an die Analytik sehr hohe Anforderungen gestellt, da die Platinmetalle zu den seltensten Elementen in der Erdkruste gehoeren (1x10{sup -7}%-10x10{sup -7}%). Die Elementmengen bzw. -konzentrationen, die nachgewiesen und bestimmt werden muessen, liegen im Bereich von 10{sup -12} g, respektive 10{sup -9} g/kg(L). Im Vergleich zum Vorkommen anderer umweltrelevanter Elemente (z.B. Blei, Cadmium) sind dies um etwa drei Groessenordnungen niedrigere Konzentrationen. (orig.)

  5. Contribution to improving extreme trace analysis for platinum in biotic and environmentally relevant materials; Beitrag zur Verbesserung der extremen Spurenanalytik der Platinmetalle in biotischen und umweltrelevanten Materialien (VPT 01)

    Energy Technology Data Exchange (ETDEWEB)

    Alt, F. [Institut fuer Spektrochemie und Angewandte Spektroskopie, Dortmund (Germany)

    1997-12-31

    The declared aim of the present project was to develop reliable and powerful detection methods for platinum metals and in particular platinum. Special emphasis was placed on practicability and transferability to other applications. This meant that the sample preparation techniques and detection methods employed would have to be available to other laboratories without significant prior investment costs. On the hand the analysis method had to meet very exacting requirements because platinum metals are among the rarest substances contained in the Earth`s crust (1x10-7%-10x10-7%) and the element quantities and concentrations to be detected are in range of 10-12g or 10-9g/kg(L), respectively. These levels are approximately three orders of magnitude smaller than those relevant to other environmentally consequential elements (e.g., lead, cadmium). [Deutsch] Die Entwicklung zuverlaessiger und nachweisstarker Bestimmungsmethoden fuer Platinmetalle, besonders Platin, war das erklaerte Ziel dieses Vorhabens. Besonderer Wert sollte allerdings auch auf die Durchfuehrbarkeit und Uebertragbarkeit fuer andere Anwender gelegt werden. Dies bedeutete, dass moeglichst nur Probenvorbereitungstechniken und Bestimmungsmethoden integriert werden sollten, die ohne grosse Investitionskosten auch anderen Laboratorien zur Verfuegung stehen. Andererseits werden an die Analytik sehr hohe Anforderungen gestellt, da die Platinmetalle zu den seltensten Elementen in der Erdkruste gehoeren (1x10{sup -7}%-10x10{sup -7}%). Die Elementmengen bzw. -konzentrationen, die nachgewiesen und bestimmt werden muessen, liegen im Bereich von 10{sup -12} g, respektive 10{sup -9} g/kg(L). Im Vergleich zum Vorkommen anderer umweltrelevanter Elemente (z.B. Blei, Cadmium) sind dies um etwa drei Groessenordnungen niedrigere Konzentrationen. (orig.)

  6. Determination of trace elements in airborne particulates by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Jung, Yong Sam; Jung, Yung Joo; Jung, Eui Sik; Cho, Seung Yun

    1995-01-01

    Trace elements in airborne particulates were analyzed by instrumental neutron activation analysis(INAA) under the optimum analytical condition. Neutron irradiation for sample was done at the irradiation hole(neutron flux, 1 x 10 13 n/cm 2 s) of TRIGA MARK-III research reactor in the Korea Atomic Energy Research Institute. For the verification of the analytical method, NIST SRM-1648 and NIES CRM No.8 were chosen and analyzed. The accuracy and precision of the analysis of 40 and 24 trace elements in the samples were compared with the certified and reported values, respectively. The analytical method was found to be reliable enough when the analytical data of NIES sample were compared with those of different countries. In the analytical result of two or both of standard reference materials, relative standard deviation was within the 15% except a few elements and the relative error was within the 10%. We used this method to analyze 30 trace elements in airborne particulates collected with the high volume air sampler(PM-10) at two different locations and also confirmed the possibility to use this method as a routine monitoring tool to find out environmental pollution sources. 3 figs., 8 tabs., 19 refs. (Author)

  7. Investigation of trace elements in Elbe water by means of instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Motamedi, K.

    1977-01-01

    Investigations of trace elements in Elbe water were carried out as a contribution to environmental research, hydrology, and geochemistry. The method applied - instrumental neutron activation analysis - is described, and problems connected with the course of analysis - sample taking, handling and preparation as well as optimization of in-pile irradiation and measurement by means of γ spectrometry - are discussed and presented one by one. The computer programme set up for automatic evaluation is described in more detail. This programme AKAN has a very general concept which makes it applicable for general use. The reliability of the evaluation procedure - monostandard method - and the reproducibility of the results are discussed. For the studies, samples were taken at different times, every time from 8 positions along a long section of the Elbe. The content of solids was analyzed; in a number of samples, this was done by separating suspended and dissolved materials. Up to 38 elements were analyzed, whose local and time-dependent concentration curves are given. The contents of some elements are compared with the few available data from literature. Correlation calculations indicate a similar behaviour of single element groups and yield information on the natural origin of the trace elements and on anthropogenic influence to be noticed in the trace element contents. (orig.) [de

  8. Chemical analysis of useful trace elements in sea water

    International Nuclear Information System (INIS)

    Katoh, Shunsaku; Fujii, Ayako; Miyai, Yoshitaka; Sakane, Kohji; Ogata, Noboru.

    1983-01-01

    The methods for the analysis of useful trace elements in sea water which have been tried so far are reviewed, and these methods are described briefly from the standpoint of studying the collection of resources. Ag and Au can be determined by concentrating sea water by ion-exchange method, solvent extraction method and electrodeposition method, then the elements are measured quantitatively by activation analysis and atomic absorption spectrochemical analysis. Sr, B and Li, which exist in relatively high concentration in sea water, are determined easily by atomic absorption spectrochemical analysis and absorption spectrometry. U, Mo and V are measured suitably by concentrating the elements by coprecipitation or solvent extraction method, and measuring by fluorescence analysis and arsenazo-3 method for U and through graphite-atomic absorption analysis for Mo and V. It has been revealed that the concentration of Ag and Au in sea water is extremely low, accordingly the recovery study is not conducted recently. On the other hand, the adsorption method using hydrated titanium oxide and amidoxim adsorbents for U, Mo and V, the adsorption method using aluminum adsorbent for Li, and the adsorption method using magnesium oxide and zirconium hydroxide and the solvent extraction method for B are hopeful to recover these elements. (Yoshitake, I.)

  9. Use of activation analysis of hair in environmental protection

    International Nuclear Information System (INIS)

    Obrusnik, I.

    1982-01-01

    Human hair is very suitable for use in environmental control monitoring because trace elements concentrate in it at higher levels than in most other organs. Unlike in other biological materials, the trace element contents in hair can be determined by instrumental neutron activation analysis (INAA), as the interference by 24 Na can be eliminated by appropriate washing of hair, e.g., using the procedure recommended by IAEA. The methods of sampling, washing and sample analysis using INAA and neutron activation analysis with radiochemical separation are described including the recommended way of the presentation of results. The results are presented of analyses for trace elements in hair from both little and highly polluted areas. (Ha)

  10. Historical economic and environmental policies influencing trace metal inputs in Montevideo Bay, Río de la Plata

    International Nuclear Information System (INIS)

    Bueno, C.; Brugnoli, E.; Figueira, R.C.L.; Muniz, P.; Ferreira, P.A.L.

    2016-01-01

    Montevideo Bay is located in the middle zone of the Rio de la Plata, and since the foundation of the city, several key economic and environmental policies affected the industry, and thus, metal inputs into this ecosystem. The aim of this study is to evaluate the sedimentary geochemical record of Montevideo Bay, in order to determine the historical inputs of anthropogenic metals to the system. In addition, environmental and economic policies of the country were taken into account to infer the relationship between them and the historic metal input. Concentrations of aluminum, chromium, copper, lead, scandium and zinc were analyzed and the EF and SPI indices were calculated. The analysis showed that since Montevideo foundation, metal concentrations increased in accordance with industry development, and the indices as well as the metal concentration represent a reliable footprint of the history of different economic and environmental policies influencing historical industrial activities. - Highlights: • Trace metal record of a sediment core of Montevideo Bay/harbor was studied. • The historic inputs of metals in the area were inferred. • System degradation evolved from anthropogenic impacts. • A relationship between pollution and environmental/economic policies was discussed.

  11. Analysis of environmental sounds

    Science.gov (United States)

    Lee, Keansub

    Environmental sound archives - casual recordings of people's daily life - are easily collected by MPS players or camcorders with low cost and high reliability, and shared in the web-sites. There are two kinds of user generated recordings we would like to be able to handle in this thesis: Continuous long-duration personal audio and Soundtracks of short consumer video clips. These environmental recordings contain a lot of useful information (semantic concepts) related with activity, location, occasion and content. As a consequence, the environment archives present many new opportunities for the automatic extraction of information that can be used in intelligent browsing systems. This thesis proposes systems for detecting these interesting concepts on a collection of these real-world recordings. The first system is to segment and label personal audio archives - continuous recordings of an individual's everyday experiences - into 'episodes' (relatively consistent acoustic situations lasting a few minutes or more) using the Bayesian Information Criterion and spectral clustering. The second system is for identifying regions of speech or music in the kinds of energetic and highly-variable noise present in this real-world sound. Motivated by psychoacoustic evidence that pitch is crucial in the perception and organization of sound, we develop a noise-robust pitch detection algorithm to locate speech or music-like regions. To avoid false alarms resulting from background noise with strong periodic components (such as air-conditioning), a new scheme is added in order to suppress these noises in the domain of autocorrelogram. In addition, the third system is to automatically detect a large set of interesting semantic concepts; which we chose for being both informative and useful to users, as well as being technically feasible. These 25 concepts are associated with people's activities, locations, occasions, objects, scenes and sounds, and are based on a large collection of

  12. Atom Trap Trace Analysis for radiokrypton and radioargon dating

    Science.gov (United States)

    Williams, William; Jiang, Wei; Sun, Yun; Bailey, Kevin; Davis, Andrew; Hu, Shuiming; Lu, Zheng-Tian; Mueller, Peter; O'Connor, Thomas; Purtschert, Roland; Sturchio, Neil

    2011-05-01

    Atom Trap Trace Analysis (ATTA), a MOT-based atom counting method, is used to analyze three noble gas radioisotopes (81Kr, 85Kr, 39Ar) covering a wide range of geological ages and applications in the earth sciences. Their isotopic abundances are extremely low, in the range of 10-16 - 10-11. Yet, ATTA can trap and unmistakably detect these rare isotopes one atom at a time. The system is currently limited by the excitation efficiency of the RF discharge that produces the metastable atoms (Kr* & Ar*) needed for laser trapping. To further improve the MOT loading rate, we plan to replace the RF discharge with a photon excitation scheme that employs a VUV light source at 124 nm. The VUV source can be a lamp or a free electron laser. This work is supported by DOE, Office of Nuclear Physics and by NSF, Division of Earth Sciences.

  13. LineVISAR. A fringe-trace data analysis program

    Energy Technology Data Exchange (ETDEWEB)

    Furnish, Michael D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-02-01

    The line-imaging ORVIS or VISAR provides velocity as a function of position and time for a line on an experimental setup via a streak camera record of interference fringes. This document describes a Matlab-based program which guides the user through the process of converting these fringe data to a velocity surface. The data reduction is of the "fringe trace" type, wherein the changes in velocity at a given position on the line are calculated based on fringe motion past that point. The analyst must establish the fringe behavior up front, aided by peak-finding routines in the program. However, the later work of using fringe jumps to compensate for phase problems in other analysis techniques is greatly reduced. This program is not a standard GUI construction, and is prescriptive. At various points it saves the progress, allowing later restarts from those points.

  14. Computation and analysis of backward ray-tracing in aero-optics flow fields.

    Science.gov (United States)

    Xu, Liang; Xue, Deting; Lv, Xiaoyi

    2018-01-08

    A backward ray-tracing method is proposed for aero-optics simulation. Different from forward tracing, the backward tracing direction is from the internal sensor to the distant target. Along this direction, the tracing in turn goes through the internal gas region, the aero-optics flow field, and the freestream. The coordinate value, the density, and the refractive index are calculated at each tracing step. A stopping criterion is developed to ensure the tracing stops at the outer edge of the aero-optics flow field. As a demonstration, the analysis is carried out for a typical blunt nosed vehicle. The backward tracing method and stopping criterion greatly simplify the ray-tracing computations in the aero-optics flow field, and they can be extended to our active laser illumination aero-optics study because of the reciprocity principle.

  15. Sample handling and chemical procedures for efficacious trace analysis of urine by neutron activation analysis

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Rack, E.P.; Roman, F.R.

    1988-01-01

    Important for the determination of trace elements, ions, or compounds in urine by chemical neutron activation analysis is the optimization of sample handling, preirradiation chemistry, and radioassay procedures necessary for viable analysis. Each element, because of its natural abundance in the earth's crust and, hence, its potential for reagent and environmental contamination, requires specific procedures for storage, handling, and preirradiation chemistry. Radioassay techniques for radionuclides vary depending on their half-lives and decay characteristics. Described in this paper are optimized procedures for aluminum and selenium. While 28 Al (T 1/2 = 2.24 min) and 77m Se(T 1/2 = 17.4s) have short half-lives, their gamma-ray spectra are quite different. Aluminum-28 decays by a 1779-keV gamma and 77m Se by a 162-keV gamma. Unlike selenium, aluminum is a ubiquitous element in the environment requiring special handling to minimize contamination in all phases of its analytical determination

  16. Trace elements detection in whole food samples by Neutron Activation Analysis, k0-method

    International Nuclear Information System (INIS)

    Sathler, Márcia Maia; Menezes, Maria Ângela de Barros Correia; Salles, Paula Maria Borges de

    2017-01-01

    Inorganic elements, from natural and anthropogenic sources are present in foods in different concentrations. With the increase in anthropogenic activities, there was also a considerable increase in the emission of these elements in the environment, leading to the need of monitoring the elemental composition of foods available for consumption. Numerous techniques have been used to detect inorganic elements in biological and environmental matrices, always aiming at reaching lower detection limits in order to evaluate the trace element content in the sample. Neutron activation analysis (INAA), applying the k 0 -method, produces accurate and precise results without the need of chemical preparation of the samples – that could cause their contamination. This study evaluated the presence of inorganic elements in whole foods samples, mainly elements on trace levels. For this purpose, seven samples of different types of whole foods were irradiated in the TRIGA MARK I IPR-R1 research reactor - located at CDTN/CNEN, in Belo Horizonte, MG. It was possible to detect twenty two elements above the limit of detection in, at least, one of the samples analyzed. This study reaffirms the INAA, k 0 - method, as a safe and efficient technique for detecting trace elements in food samples. (author)

  17. Trace elements detection in whole food samples by Neutron Activation Analysis, k{sub 0}-method

    Energy Technology Data Exchange (ETDEWEB)

    Sathler, Márcia Maia; Menezes, Maria Ângela de Barros Correia, E-mail: maia.sathler@gmail.com, E-mail: menezes@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Salles, Paula Maria Borges de, E-mail: pauladesalles@yahoo.com.br [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    Inorganic elements, from natural and anthropogenic sources are present in foods in different concentrations. With the increase in anthropogenic activities, there was also a considerable increase in the emission of these elements in the environment, leading to the need of monitoring the elemental composition of foods available for consumption. Numerous techniques have been used to detect inorganic elements in biological and environmental matrices, always aiming at reaching lower detection limits in order to evaluate the trace element content in the sample. Neutron activation analysis (INAA), applying the k{sub 0}-method, produces accurate and precise results without the need of chemical preparation of the samples – that could cause their contamination. This study evaluated the presence of inorganic elements in whole foods samples, mainly elements on trace levels. For this purpose, seven samples of different types of whole foods were irradiated in the TRIGA MARK I IPR-R1 research reactor - located at CDTN/CNEN, in Belo Horizonte, MG. It was possible to detect twenty two elements above the limit of detection in, at least, one of the samples analyzed. This study reaffirms the INAA, k{sub 0} - method, as a safe and efficient technique for detecting trace elements in food samples. (author)

  18. Trace fossil analysis of lacustrine facies and basins

    Science.gov (United States)

    Buatois, L.A.; Mangano, M.G.

    1998-01-01

    Two ichnofacies are typical of lacustrine depositional systems. The Scoyenia ichnofacies characterizes transitional terrestrial/nonmarine aquatic substrates, periodically inundated or desiccated, and therefore is commonly present in lake margin facies. The Mermia ichnofacies is associated with well oxygenated, permanent subaqueous, fine-grained substrates of hydrologically open, perennial lakes. Bathymetric zonations within the Mermia ichnofacies are complicated by the wide variability of lacustrine systems. Detected proximal-distal trends are useful within particular lake basins, but commonly difficult to extrapolate to other lakes. Other potential ichnofacies include the typically marine Skolithos ichnofacies for high-energy zones of lakes and substrate-controlled, still unnamed ichnofacies, associated to lake margin deposits. Trace fossils are useful for sedimentologic analysis of event beds. Lacustrine turbidites are characterized by low-diversity suites, reflecting colonization by opportunistic organisms after the turbidite event. Underflow current beds record animal activity contemporaneous with nearly continuous sedimentation. Ichnologic studies may also help to distinguish between marine and lacustrine turbidites. Deep-marine turbidites host the Nereites ichnofacies that consists of high diversity of ornate grazing traces and graphoglyptids, recording highly specialized feeding strategies developed to solve the problem of the scarcity of food in the deep sea. Deep lacustrine environments contain the Mermia ichnofacies, which is dominated by unspecialized grazing and feeding traces probably related to the abundance and accessibility of food in lacustrine systems. The lower diversity of lacustrine ichnofaunas in comparison with deep-sea assemblages more likely reflects lower species diversity as a consequence of less stable conditions. Increase of depth and extent of bioturbation through geologic time produced a clear signature in the ichnofabric record of

  19. Mapping of Trace Elements in Coal and Ash Research Based on a Bibliometric Analysis Method Spanning 1971–2017

    Directory of Open Access Journals (Sweden)

    Liu Yang

    2018-02-01

    Full Text Available Coal is the most important fossil energy used in China. The environmental impact of trace elements released in coal combustion has become one of the hottest issues in recent years. Based on a software named CiteSpace, and social network analysis (SNA, a bibliometric analysis of research into trace elements in coal and ash field during 1971–2017 is presented with the information of authors, countries, institutions, journals, hot issues and research trends in the present study. The study results indicate that: (1 Shifeng Dai, Robert B Finkelman, Guijian Liu and James C Hower have a large number of publications with great influence. (2 China (29.8% and USA (22.2% have high productivity in total publications. China and the USA correlate closely in the cooperative web system. (3 China University of Mining and Technology and Chinese Academy of Sciences take the leading position in the quantity of publications among all research institutions. (4 Energy and fuels, engineering and environmental science are three disciplines with the most studies in this field. (5 International Journal of Coal Geology, Fuel, Energy and Fuels and Fuel Processing Technology are the top four journals with the most publications in this field. (6 The enrichment origin and modes of occurrence of trace elements are the mainstream research related to trace elements in coal and ash. The environmental problems caused by coal combustion have promoted the development of trace elements in coal research, and human health is getting more and more popular in recent years. The study findings provide a better understanding of features of trace elements in coal and ash research, which could be taken as a reference for future studies in this field.

  20. Trace analysis of actinides in the environment using resonance ionization mass spectrometry

    International Nuclear Information System (INIS)

    Raeder, Sebastian

    2011-01-01

    In this work the resonant ionization of neutral atoms using laser radiation was applied and optimized for ultra-trace analysis of the actinides thorium, uranium, neptunium and plutonium. The sensitive detection of these actinides is a challange for the monitoring and quantification of radioactive releases from nuclear facilities. Using resonance ionization spectroscopy combined with a newly developed quadrupole-mass-spectrometer, numerous energy levels in the atomic structure of these actinides could be identified. With this knowledge efficient excitation schemes for the mentioned actinides could be identified and characterised. The applied in-source-ionization ensures for a high detection efficiency due to the good overlap of laser radiation with the atomic beam and allows therefore for a low sample consumption which is required for the analysis of radio nuclides. The selective excitation processes in the resonant ionization method supresses unwanted contaminations and was optimized for analytical detection of ultra-trace amounts in environmental samples as well as for determination of isotopic compositions. The efficient in-source-ionization combined with high power pulsed laser radiation allows for detections efficiency up to 1%. For plutonium detection limits in the range of 10 4 -10 5 atoms could be demonstrated for synthetic samples as well as for first environmental samples. The usage of narrow bandwidth continuous wave lasers in combination with a transversal overlap of the laser radiation and the free propagating atomic beam enable for resolving individual isotopic shifts of the resonant transitions. This results in a high selectivity against dominant neighboring isotopes but with a significant loss in detection efficiency. For the ultra-trace isotope 236 U a detection limit down to 10 -9 for the isotope ratio N ( 236 U)/N ( 238 U) could be determined.

  1. Medical and health-related trace element analysis by TXRF

    International Nuclear Information System (INIS)

    Greaves, E.D.

    2000-01-01

    The advantages offered with TXRF analysis by direct irradiation with monochromatic X-rays of tissue homogenates and body fluids make the technique appropriate for a number of medical and health related applications. The ability to detect low levels of toxic heavy elements is being used as an aid in accidental poisoning diagnosis and treatment, in treatment-induced toxicity control and as an accessory in medical and health research. Thus lead-in-whole-blood analysis is used in confirmation of diagnosis of victims of poisoning, or monitoring the evolution and efficiency of the clinical treatment. Measurement and control of plasma platinum levels of cancer patients undergoing chemotherapy with Pt-containing drugs includes: establishment of the drug level-tumor remission response, measurement of Pt plasma level curves and establishment of optimum dosage to minimize the nephrotoxicity of platinum, and bioequivalence comparisons of different commercially available platinum containing anticancer drugs. Analysis as an aid in clinical research applications includes: trace element determination of amniotic fluid in fetus malformation studies; analysis of brain specimens and cerebrospinal fluid in diagnosis of central nervous system disorders; the influence of trace elements in cataract genesis and the influence of heavy elements in semen quality in human reproduction studies. Human body samples require the use of monochromatized beams of x-rays in order to derive the special advantage of its use: i) The reduction in the spectrum background allowing direct irradiation of organic matter specimens. Hence human tissue and body fluids are prepared by simple procedures involving dilution, homogenization and standard addition avoiding the need for specimen digestion. This results in faster, cheaper methods that decrease sample contamination problems. ii) The presence of a large Compton scattered signal in the spectrum and its use as an internal standard reference allows further

  2. Neutron activation analysis of trace elements in rain water

    International Nuclear Information System (INIS)

    Luten, J.B.

    1977-01-01

    In this thesis the principles and practical aspects of activation analysis which are of direct importance in the analysis of rain water, are presented together with recent literature data on other techniques. Problems due to the storage of rain water samples are discussed. A multi-element method for the determination of trace elements in rain water by instrumental neutron activation analysis is described. Gamma ray spectrometry using Ge(Li) detectors offers the possibility to determine Na, Al, Cl, V, Mn, Co, Cu, Br and I in rain water samples of 2.5 ml after a 4-min irradiation in a thermal neutron flux of 5 x 10 13 n cm -2 s -1 . In residues of rain water samples of 100 ml, irradiated during 2 days in a thermal neutron flux of >5 x 10 13 n cm -2 s -1 Cr, Fe, Co, Zn and Sb can be determined after a cooling period of approximately 21 days. The detection limits are lower than those reported in previous investigations except for Cu. The precision is about 10% or better, except for Co, Cu and I. A routine method for the determination of bromine and iodine in rain water by n.a.a. is presented. The elements are isolated by isotope exchange between the irradiated sample and a solution of Br 2 or I 2 in CCl 4 . The method is not sensitive to the chemical species in which the halogen is present. Irradiation of solutions of iodine compounds in a high thermal neutron flux gives rise to the formation of iodate. Results of a further investigation of this phenomenon are given, as well as the determination of iodate in rain water by n.a.a. Iodate is separated by anion exchange. The combination of n.a.a. and solvent extraction is used for the determination of five trace elements (V, Co, Cu, Zn and In) in 10-ml rain water samples. For V, Co and Cu this method is more sensitive and reproducible than instrumental n.a.a. The results of the analysis of eleven sequential 30-ml samples from the beginning of the shower are presented as an illustration of possible applications of the

  3. Trace element analysis of common salt using neutron activation analysis

    International Nuclear Information System (INIS)

    Usman, K.

    1993-01-01

    Instrumental Fast Neutron Activation Analysis (IFNAA) technique has been used in the qualitative and quantitative determination of the impurity elements in common salt. Samples of the different types of common salt processed in Nigeria and some of those imported into the country were used. The type A711 KAMAN neutron generator and a high-purity Germanium (HpGe) gamma spectrometer available at the Centre for Energy Research and Training, Ahmadu Bello University, Zaria has been used. The ORTEC ADCAM 100 Emulation Software (Maestro) was used in the qualitative measurement of the detected elements. The G.R.G Activation Analysis System by G. R. Gilmore, 1987, was used in the quantitative determination of the elements detected by relative method. Aluminium and arsenic were detected and measured

  4. Contribution to optimisation of Environmental Isotopes tracing in Hydrogeology. Case study of Madagascar

    International Nuclear Information System (INIS)

    RAJAOBELISON, J.

    2003-01-01

    The aim of this work is to suggest some improvements on the theory of interpretation and on the methodological approach for the optimum use of environmental isotopes tracing applied to hydrogeological investigation. A review of the theory of environmental isotopes used in hydrogeology has been made. The main constraints have been highlighted and led to some comments and proposals of improvement, in particular with regard to the continental effect on stable isotopes, to the seasonal variation of groundwater 1 4C content, and to the appropriate model for fractured crystalline aquifers. A literature survey on ten specific scientific papers, dealing with isotopic hydrology in miscellaneous types of aquifers and catchments, allowed to draw a synthesis of the hydrogeological, geochemical and isotopic constraints. A proposal of optimum methodological approach, taking into account the above mentioned constraints, have been inferred. The results of an on-going hydrogeological investigation carried out in the Southern crystalline basement and coastal sedimentary aquifers of Madagascar highlights an unusual methodological approach based on the lack of initial basic hydrogeological data. Besides, it shows to what extent the experience of the above mentioned research works can apply in the specific case of the complex aquifers of Madagascar. The lessons gained from this study contribute to enrich the synthesis of environmental isotopes constraints in hydrogeology and lead to a more realistic methodological approach proposal wich is likely to better make profitable the isotope hydrology technology

  5. Evaluating the suitability of different environmental samples for tracing atmospheric pollution in industrial areas.

    Science.gov (United States)

    Francová, Anna; Chrastný, Vladislav; Šillerová, Hana; Vítková, Martina; Kocourková, Jana; Komárek, Michael

    2017-01-01

    Samples of lichens, snow and particulate matter (PM 10 , 24 h) are used for the source identification of air pollution in the heavily industrialized region of Ostrava, Upper Silesia, Czech Republic. An integrated approach that uses different environmental samples for metal concentration and Pb isotope analyses was applied. The broad range of isotope ratios in the samples indicates a combination of different pollution sources, the strongest among them being the metallurgical industry, bituminous coal combustion and traffic. Snow samples are proven as the most relevant indicator for tracing metal(loid)s and recent local contamination in the atmosphere. Lichens can be successfully used as tracers of the long-term activity of local and remote sources of contamination. The combination of PM 10 with snow can provide very useful information for evaluation of current pollution sources. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Storage and pre-neutron-activation-analysis treatment for trace-element analysis in urine

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Rack, E.P.

    1985-01-01

    The problems regarding storage and pre-neutron-activation-analysis treatment for the elements aluminum, calcium, vanadium, selenium, copper, iodine, zinc, manganese, and magnesium in a urine matrix are reviewed. The type of collection and storage procedure and pre-neutron activation analysis treatment of urine depend on the specific trace element; that is, its inherent physical and chemical properties. Specifically polyethylene in teflon containers are the most suitable for general determinations. Whether any preservative is added would depend upon the stability of the trace element and its tendency for surface adsorption. Preferably, preservatives should contain no radioactivatable elements for maximum efficacy. Freeze drying or packing urine shipments under dry ice needs to be explored on an individual basis. Each pre- or post-neutron activation analysis treatment is specific and optimized for the trace element analyzed

  7. Neutron activation analysis of trace elements in foodstuffs

    International Nuclear Information System (INIS)

    Schelenz, R.; Bayat, I.; Fischer, E.

    1976-05-01

    For the determination of trace elements in foodstuffs with the aid of neutron activation analysis the separation of volatile radionuclides after digestion of the sample is of special interest for radiochemical processing. A distillation procedure was developed to give reproducable results, however optimal conditions were not found for all volatile radionuclides studied. The required selective separation of Br-82 from the distillate was best achieved by the application of an ion-exchange column-chromatography technique. The computer programs for the evaluation of complex gamma spectra have been developed further. The automatic peak search and peak area determination is based on a computer program using the correlation technique and carried out with a mini-computer coupled with a multi-channel gamma spectrometer. The results, which are presented in 3 earlier reports relating to this research program, reveal the advantages and disadvantages of the individual steps of the radiochemical separation scheme. Before neutron activation analysis can be introduced on a routine basis, some aspects of the radiochemical process remain to be tested; these studies will be published in a fourth and final report. (orig.) [de

  8. Express-analysis of Radiocaesium Traces in Natural Water

    International Nuclear Information System (INIS)

    Remez, V.P.; Belyakova, E.G.

    1999-01-01

    To determine traces of radiocaesium in water solution, the sorbent on the base of ferric potassium hexacyanoferrate on cellulose carrier ANFEZH was worked out. The sorbent is capable to extract effectively the isotopes of caesium from various natural solutions (fresh and sea water, milk, juices and so on). The usage of sorbent allows practically completely concentrate the isotopes of caesium from water samples with the volume of tens and hundreds litres. The sorbent in quantity of 50-500 grams allows to extract 98±1% of caesium from natural water samples with the volume up to 1000 litres during 1-5 hours. The usage of this sorbent allowed to conduct the express analysis of multiple bore holes within the area of 30 km of Chernobyl Skaya NPP , drinking water and milk in the regions of Belorussia, Ukraine and Russia, hit by Chernobyl disaster and around NPP in Russia and America. The use of this express analysis reduced the time and required labour as compared with to precipitation methods

  9. X-ray trace element analysis with positive ion beams

    International Nuclear Information System (INIS)

    Davis, R.H.

    1973-01-01

    A new trace element analysis having the advantage that many elements may be detected in a single measurement, based on positive charged particle induced X-ray florescence and on the production of X-rays by heavy ions, is described. Because of the large cross-sections for the production of discrete X-ray and the low yield of continuum radiation, positive charged particle X-ray florescence is a competitive, fast, analytic tool. In the experiment a beam of positive charged particles from an accelerator was directed toward a target. X-rays induced by the bombardment were detected by a Si(Li) detector the ouput from which was amplified and sorted in a multichannel analyzer. For rapid data handling and analysis, the multichannel analyzer or ADC unit was connected to an on-line computer. A large variety of targets prepared in collaboration with the oceanographers have been studied and spectra obtained for different particles having the same velocity are presented to show that the yield of discrete X-rays increases at least as rapidly as Z 2 . While protons of several MeV appear to be already competitive further advantage may be gained by heavy ions at lower energies since the continuum is reduced while the peak ''signals'' retain strength due to the Z 2 dependence. (S.B.)

  10. Application of the neutron activation analysis technique in trace elements analysis

    International Nuclear Information System (INIS)

    Khamis, I.; Sarheel, A.; Al-Somel, N.

    2006-12-01

    The main objective in this study is the implementation k 0 -standardization method (single comparator method) using gold comparator as a routine method in neutron activation analysis laboratory in Engineering Nuclear Department. Cadmium ratio Rcd; Cd-ratio = [A s p/(A s p) C d] and the nuclear reactor constants (f=φ t h/φ e pi subcadimum thermal- to- epithermal neutron flux ratio and α with describing the φ e (E)∼ 1/E 1+α neutron flux distribution) were determined in the inner and outer irradiation sites at MNS Reactor. K 0 -IAEA software, which provided by the Agency, has been installed and applied in our laboratory. Trace elements in many kinds of samples (biological, environmental, alloy ...etc) were determined using K 0 -IAEA software. The results of standard reference materials (SRM's) obtained in this work show a good agreement with the certified values, and we got these results with a good accuracy closer to results which we got from relative NAA method. (author)

  11. Uncertainty analysis of environmental models

    International Nuclear Information System (INIS)

    Monte, L.

    1990-01-01

    In the present paper an evaluation of the output uncertainty of an environmental model for assessing the transfer of 137 Cs and 131 I in the human food chain are carried out on the basis of a statistical analysis of data reported by the literature. The uncertainty analysis offers the oppotunity of obtaining some remarkable information about the uncertainty of models predicting the migration of non radioactive substances in the environment mainly in relation to the dry and wet deposition

  12. Environmental analysis for pipeline gas demonstration plants

    Energy Technology Data Exchange (ETDEWEB)

    Stinton, L.H.

    1978-09-01

    The Department of Energy (DOE) has implemented programs for encouraging the development and commercialization of coal-related technologies, which include coal gasification demonstration-scale activities. In support of commercialization activities the Environmental Analysis for Pipeline Gas Demonstration Plants has been prepared as a reference document to be used in evaluating potential environmental and socioeconomic effects from construction and operation of site- and process-specific projects. Effluents and associated impacts are identified for six coal gasification processes at three contrasting settings. In general, impacts from construction of a high-Btu gas demonstration plant are similar to those caused by the construction of any chemical plant of similar size. The operation of a high-Btu gas demonstration plant, however, has several unique aspects that differentiate it from other chemical plants. Offsite development (surface mining) and disposal of large quantities of waste solids constitute important sources of potential impact. In addition, air emissions require monitoring for trace metals, polycyclic aromatic hydrocarbons, phenols, and other emissions. Potential biological impacts from long-term exposure to these emissions are unknown, and additional research and data analysis may be necessary to determine such effects. Possible effects of pollutants on vegetation and human populations are discussed. The occurrence of chemical contaminants in liquid effluents and the bioaccumulation of these contaminants in aquatic organisms may lead to adverse ecological impact. Socioeconomic impacts are similar to those from a chemical plant of equivalent size and are summarized and contrasted for the three surrogate sites.

  13. LASER SPECTROSCOPY AND TRACE ELEMENT ANALYSIS Chapter from the Energy and Environment Division Annual Report 1980

    Energy Technology Data Exchange (ETDEWEB)

    Various, Authors

    1981-05-01

    In order to control pollutants resulting from energy production and utilization, adequate methods are required for monitoring the level of various substances often present at low concentrations. The Energy and Environment Division Applied Research in Laser Spectroscopy & Analytical Techniques Program is directed toward meeting these needs, Emphasis is on the development of physical methods, as opposed to conventional chemical analysis techniques. The advantages, now widely recognized, include ultra-high sensitivity coupled with minimal sample preparation. In some instances physical methods provide multi-parameter measurements which often provide the only means of achiev·ing the sensitivity necessary for the detection of trace contaminants. Work is reported in these areas: APPLIED PHYSICS AND LASER SPECTROSCOPY RESEARCH; MICROPROCESSOR CONTROLLER ANODIC STRIPPING VOLTAMETER FOR TRACE METALS ANALYSIS IN WATER; THE SURVEY OF INSTRUMENTATION FOR ENVIRONMENTAL MONITORING; THE POSSIBLE CHRONDRITIC NATURE OF THE DANISH CRETACEOUS~TERTIARY BOUNDARY; IMPROVEMENT OF THE SENSITIVITY AND PRECISION OF NEUTRON ACTIVATION ANALYSIS OF SOME ELEMENTS IN PLANKTON AND PLANKTONIC FISH; and SOURCES OF SOME SECONDARILY WORKED OBSIDIAN ARTIFACTS FROM TIKAL, GUATEMALA.

  14. Timor-Leste : Country Environmental Analysis

    OpenAIRE

    World Bank

    2009-01-01

    The Country Environmental Analysis (CEA) for Timor-Leste identifies environmental priorities through a systematic review of environmental issues in natural resources management and environmental health in the context of the country's economic development and environmental institutions. Lack of data has been the main limitation in presenting a more rigorous analysis. Nevertheless, the repor...

  15. Preconcentration and Speciation of Trace Elements and Trace-Element Analogues of Radionuclides by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Chatt, A.

    1999-01-01

    We have developed a number of preconcentration neutron activation analysis (PNAA) methods in our laboratory for the determination of trace elements in a variety of complex sample matrices. We developed a number of cocrystallization and coprecipitation methods for the determination of trace elements in water samples. We developed several methods for the determination of I in foods and diets. We have developed a number of PNAA methods in our laboratory We determined As and Sb in geological materials and natural waters by coprecipitation with Se and Au in silicate rocks and ores by coprecipitation with Te followed by NAA. We developed an indirect NAA method for the determination of B in leachates of borosilicate glass. We have been interested in studying the speciation of Am, Tc, and Np in simulated vitrified groundwater leachates of high-level wastes under oxid and anoxic conditions using a number of techniques. We then used PNAA methods to study speciation of trace-element analogues of radionuclides. We have been able to apply biochemical techniques and NAA for the separation, preconcentration, and characterization of metalloprotein and protein-bound trace-element species in subcellular fractions of bovine kidneys. Lately, we have concentrated our efforts to develop chemical and biochemical methods in conjunction with NAA, NMR, and MS for the separation and identification of extractable organohalogens (EOX) in tissues of beluga whales, cod, and northern pink shrimp

  16. Application of resonance ionization mass spectrometry for trace analysis and in fundamental research

    International Nuclear Information System (INIS)

    Passler, G.

    1997-01-01

    Resonance ionization mass spectrometry (RIMS) has been used for ultra-trace analysis on long-lived radioisotopes like Pu, Tc and 89,90 Sr in various environmental samples. The experimental approaches cover pulsed laser spectroscopy on a thermal atomic beam and subsequent time-of-flight mass analysis, a pulsed laser ion source combined with conventional mass spectrometry, and collinear resonance ionization on a mass-separated fast atomic beam. The high sensitivity of RIMS also enables atomic spectroscopy on rare isotopes. For the first time experimental values for the ionization potential of actinides up to Cf have been determined. The paper reviews the dependency of the different experimental approaches on the analytical problem. copyright 1997 American Institute of Physics

  17. Trace element analysis of silicate rocks by XRF. Pt. 2

    International Nuclear Information System (INIS)

    Orihashi, Yuji; Yuhara, Masaki; Kagami, Hiroo; Honma, Hiroji

    1993-01-01

    Quantitative X-ray fluorescence analysis of six trace elements (Ce, Ba, Ga, Co, Cr, V) in silicate rocks has been investigated, using pressed powder pellets. Ga analysis was performed using a Cr tube, whereas a Au tube was used for the remaining five elements. Corrections were made for the interference of BaKα on CeKα, FeKβ on CoKα, CrKα on VKβ and VKα on TiKβ. Mass absorption functions were estimated from background intensities at 2θ=35.5deg and that of FeKα at wavelengths longer than the iron absorption edge for a Au tube, and from the value of net intensity/background one for a Cr tube. Calibration lines were constructed using twenty-four U.S. Geological Survey and Geological Survey of Japan igneous rock reference samples. For each line, the correction coefficient is greater than 0.993 except for Ga and Ce (>0.985), indicating that the correction and calibration procedures are appropriate for accurate analysis over a wide compositional range. Analytical results for igneous, sedimentary and metamorphic reference samples (U. S. Geological Survey, Institute of Geophysical and Geochemical Exploration, South-African Bureau of Standards) accord well with recommended or proposed values, respectively. The results of this study and those of Orihashi et al. (1993) show Ce, Ba, Nb, Zr, Y, Sr, Rb, Th, Ga, Zn, Cu, Ni, Co, Cr and V in silicate rocks can be quantitatively determined by XRF at ISEI. (author)

  18. MOLECULARLY IMPRINTED SOLID PHASE EXTRACTION FOR TRACE ANALYSIS OF DIAZINON IN DRINKING WATER

    Directory of Open Access Journals (Sweden)

    M. Rahiminejad ، S. J. Shahtaheri ، M. R. Ganjali ، A. Rahimi Forushani ، F. Golbabaei

    2009-04-01

    Full Text Available Amongst organophosphate pesticides, the one most widely used and common environmental contaminant is diazinon; thus methods for its trace analysis in environmental samples must be developed. Use of diazinon imprinted polymers such as sorbents in solid phase extraction, is a prominent and novel application area of molecular imprinted polymers. For diazinon extraction, high performance liquid chromatography analysis was demonstrated in this study. During optimization of the molecular imprinted solid phase extraction procedure for efficient solid phase extraction of diazinon, Plackett-Burman design was conducted. Eight experimental factors with critical influence on molecular imprinted solid phase extraction performance were selected, and 12 different experimental runs based on Plackett-Burman design were carried out. The applicability of diazinon imprinted polymers as the sorbent in solid phase extraction, presented obtained good recoveries of diazinon from LC-grade water. An increase in pH caused an increase in the recovery on molecular imprinted solid phase extraction. From these results, the optimal molecular imprinted solid phase extraction procedure was as follows: solid phase extraction packing with 100 mg diazinon imprinted polymers; conditioning with 5 mL of methanol and 6 mL of LC-grade water; sample loading containing diazinon (pH=10; washing with 1 mL of LC-grade water, 1 mL LC- grade water containing 30% acetonitrile and 0.5 mL of acetonitrile, respectively; eluting with 1 mL of methanol containing 2% acetic acid. The percentage recoveries obtained by the optimized molecular imprinted solid phase extraction were more than 90% with drinking water spiked at different trace levels of diazinon. Generally speaking, the molecular imprinted solid phase extraction procedure and subsequent high performance liquid chromatography analysis can be a relatively fast and proper approach for qualitative and quantitative analysis of diazinon in

  19. Tracing overhead transmission line corridors with regard to environmental and spatial qualities

    Directory of Open Access Journals (Sweden)

    Alenka Cof

    2005-01-01

    Full Text Available The article deals with possibilities for running the proposed overhead transmission line Okroglo-Italian border. The Slovene and Italian methods are shown as methods enabling consideration of environmental and spatial impact within the process of planning overhead transmission line corridors. The Slovene method consists of analyses of attractiveness and vulnerability, whereby the first considers those functional and economic factors that affect spatial attractiveness for overhead transmission lines. Thus we can assess the level of economic and functional suitability of alternative routes of the proposed 400 kilovolt overhead transmission line from transformation station Okroglo (Slovenia to Srednje, Golo Brdo and Vrtojba, three potential contact points on the Slovene–Italian border. In accordance with stipulations of the Law on spatial management vulnerability models were prepared, which were used to simulate the development’s potential negative environmental effects and to analyse suitability, which implies harmonisation of development and protection demands. Their result is a possible corridor that can be developed without significant conflicts. The Italian procedure was developed to trace the transmission line corridor from the Slovenian border to the transformation station in Udine. It was also applied on the Slovenian side. Three groups of factors were considered in the procedure: exclusion, repulsion, and attraction. The much simpler procedure enables comparisons, since it uses the same or at least similar spatial data. In conclusion a short commentary is added about the corridor concept as a planning tool.

  20. Hyperspectral imaging for non-contact analysis of forensic traces

    NARCIS (Netherlands)

    Edelman, G. J.; Gaston, E.; van Leeuwen, T. G.; Cullen, P. J.; Aalders, M. C. G.

    2012-01-01

    Hyperspectral imaging (HSI) integrates conventional imaging and spectroscopy, to obtain both spatial and spectral information from a specimen. This technique enables investigators to analyze the chemical composition of traces and simultaneously visualize their spatial distribution. HSI offers

  1. Nuclear reaction analysis (NRA) for trace element detection

    Energy Technology Data Exchange (ETDEWEB)

    Doebeli, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Noll, K. [Bern Univ. (Switzerland)

    1997-09-01

    Ion beam induced nuclear reactions can be used to analyse trace element concentrations in materials. The method is especially suited for the detection of light contaminants in heavy matrices. (author) 3 figs., 2 refs.

  2. Modified interstitial water squeezer for trace metal analysis

    Digital Repository Service at National Institute of Oceanography (India)

    Nath, B.N.; Rajaraman, V.S.; Mudholkar, A.V.

    Hydraulic squeezer of Manheim, used in the extraction of pore water of sediments, has been modified by providing teflon inner lining and increasing the volume of squeezer. The modified version facilitates collection of pore water sample, for trace...

  3. Selected environmental applications of neutron activation analysis

    International Nuclear Information System (INIS)

    Kucera, J.

    2001-01-01

    NAA is very useful for the determination of trace and minor elements in many environmental applications. While instrumental NAA (INAA) has a number of valid applications in this field, radiochemical NAA (RNAA) prior to, or post irradiation provides some significant advantages. One of the major focus points for environmental applications of NAA is to assess the magnitude of various pollutants. This paper discusses doing this via two methods, namely air monitoring and biological monitoring. (author)

  4. PIXE - Analysis for environmental and biological samples

    International Nuclear Information System (INIS)

    Baptista, G.B.

    1980-04-01

    The usefulness and accuracy of PIXE as an analytical tool in the study of trace elements in environmental samples of the Brazilian Cerrado are discussed. The report lists actual and forthcoming publications resulting from the study. The mechanism of exchange of elements in solution in water to aerosols has been investigated. For details of the procedure the reader is referred to an earlier report

  5. Relationship between trace element content in human organs and hair - significance of hair mineral analysis as a means for assessing internal body burdens of environmental mineral pollutants. Final report for the period October 1984 - September 1988

    Energy Technology Data Exchange (ETDEWEB)

    Kinova, L [Bulgarian Academy of Sciences, Sofia (Bulgaria). Inst. of Nuclear Research and Nuclear Energy

    1988-12-31

    The purpose of the project was to establish a possibility to use hair as a monitor for internal body burden with toxic metals. For this purpose samples of human organs (heart, spleen, liver, kidney) and hair were analysed by neutron activation analysis and radiochemical techniques for the determination of As, Cd, Hg, Cu, Zn, Se, Ca, K, Mg, Mn, Na, S. 6 refs, 4 tabs.

  6. The effects of trace elements, cations, and environmental conditions on protocatechuate 3,4-dioxygenase activity

    Directory of Open Access Journals (Sweden)

    Andréa Scaramal da Silva

    2013-04-01

    Full Text Available Phenanthracene is a highly toxic organic compound capable of contaminating water and soils, and biodegradation is an important tool for remediating polluted environments. This study aimed to evaluate the effects of trace elements, cations, and environmental conditions on the activity of the protocatechol 3,4-dioxygenase (P3,4O enzyme produced by the isolate Leifsonia sp. in cell-free and immobilized extracts. The isolate was grown in Luria Bertani broth medium (LB amended with 250 mg L-1 of phenanthrene. Various levels of pH (4.0-9.0, temperature (5-80 °C, time (0-90 min, trace elements (Cu2+, Hg2+ and Fe3+, and cations (Mg2+, Mn2+, K+ and NH4+ were tested to determine which conditions optimized enzyme activity. In general, the immobilized extract exhibited higher enzyme activity than the cell-free extract in the presence of trace elements and cations. Adding iron yielded the highest relative activity for both cell-free and immobilized extracts, with values of 16 and 99 %, respectively. Copper also increased enzyme activity for both cell-free and immobilized extracts, with values of 8 and 44 %, respectively. Enzyme activity in the phosphate buffer was high across a wide range of pH, reaching 80 % in the pH range between 6.5 and 8.0. The optimum temperatures for enzyme activity differed for cell-free and immobilized extracts, with maximum enzyme activity observed at 35 ºC for the cell-free extract and at 55 ºC for the immobilized extract. The cell-free extract of the P3,4O enzyme exhibited high activity only during the first 3 min of incubation, when it showed 50 % relative activity, and dropped to 0 % after 60 min of incubation. By contrast, activity in the immobilized extract was maintained during 90 min of incubation. This isolate has important characteristics for phenanthrene biodegradation, producing high quantities of the P3,4O enzyme that forms part of the most important pathway for PAH biodegradation.

  7. Statistical analysis of environmental data

    International Nuclear Information System (INIS)

    Beauchamp, J.J.; Bowman, K.O.; Miller, F.L. Jr.

    1975-10-01

    This report summarizes the analyses of data obtained by the Radiological Hygiene Branch of the Tennessee Valley Authority from samples taken around the Browns Ferry Nuclear Plant located in Northern Alabama. The data collection was begun in 1968 and a wide variety of types of samples have been gathered on a regular basis. The statistical analysis of environmental data involving very low-levels of radioactivity is discussed. Applications of computer calculations for data processing are described

  8. The role of neutron activation analysis for trace elements characterization, analysis and certification in atmospheric particulates

    International Nuclear Information System (INIS)

    Rizzio, Enrico; Gallorini, Mario

    2002-01-01

    The Neutron Activation Analysis (NAA) owns these requirements and is universally accepted as one of the most reliable analytical tools for trace and ultratrace elements determination. Its use in trace elements atmospheric pollution related studies has been and is still extensive as can be demonstrate by several specific works and detailed reviews. In this work, the application of this nuclear technique, in solving a series of different analytical problems related to trace elements in air pollution processes is reported. Examples and results are given on the following topics: characterization of urban and rural airborne particulate samples; particles size distribution in the different inhalable and respirable fractions (PM10 and PM 2.5); certification of related Standard Reference Materials for data quality assurance. (author)

  9. Trace analysis for 300 MM wafers and processes with TXRF

    International Nuclear Information System (INIS)

    Nutsch, A.; Erdmann, V.; Zielonka, G.; Pfitzner, L.; Ryssel, H.

    2000-01-01

    Efficient fabrication of semiconductor devices is combined with an increasing size of silicon wafers. The contamination level of processes, media, and equipment has to decrease continuously. A new test laboratory for 300 mm was installed in view of the above mentioned aspects. Aside of numerous processing tools this platform consist electrical test methods, particle detection, vapor phase decomposition (VPD) preparation, and TXRF. The equipment is installed in a cleanroom. It is common to perform process or equipment control, development, evaluation and qualification with monitor wafers. The evaluation and the qualification of 300 mm equipment require direct TXRF on 300 mm wafers. A new TXRF setup was installed due to the wafer size of 300 mm. The 300 mm TXRF is equipped with tungsten and molybdenum anode. This combination allows a sensitive detection of elements with fluorescence energy below 10 keV for tungsten excitation. The molybdenum excitation enables the detection of a wide variety of elements. The detection sensitivity for the tungsten anode excited samples is ten times higher than for molybdenum anode measured samples. The system is calibrated with 1 ng Ni. This calibration shows a stability within 5 % when monitored to control system stability. Decreasing the amount of Ni linear results in a linear decrease of the measured Ni signal. This result is verified for a range of elements by multielement samples. New designs demand new processes and materials, e.g. ferroelectric layers and copper. The trace analysis of many of these materials is supported by the higher excitation energy of the molybdenum anode. Reclaim and recycling of 300 mm wafers demand for an accurate contamination control of the processes to avoid cross contamination. Polishing or etching result in modified surfaces. TXRF as a non-destructive test method allows the simultaneously detection of a variety of elements on differing surfaces in view of contamination control and process

  10. Simultaneous speciation neutron activation analysis for trace elements

    International Nuclear Information System (INIS)

    Chatt, A.; Kiceniuk, J.W.; Menendez Sanchez, W.; Bottaro, C.

    2006-01-01

    Among the various forms of neutron activation technique being developed in our laboratory, much emphasis has been placed over the last ten years or so on the development of simultaneous speciation neutron activation analysis (SSNAA). This technique can now be used for the simultaneous determination of various species of a number of elements. Almost all speciation techniques consist of two steps. The first step involves the separation of species from the sample followed by the second step of element-specific detection. A number of characteristic features of NAA, which other techniques normally do not possess, can be advantageously exploited in SSNAA. For example, SSNAA can be used for: (i) multielement speciation with high specificity, (ii) speciation of chemically dissimilar elements such as Cd, Mn and Se, (iii) speciation of elements such as Cl, Br and I which are rather difficult to determine by most other techniques, etc. We have developed SSNAA methods for assaying various arsenic species, namely As(III), As(V), dimethyl arsonic acid (DMA), monomethylarsinic acid (MMA), arsenobetaine (AsB), organically bound arsenic (OBAs), and lipid-soluble arsenic (LSAs) in marine fish samples. We have extended these methods to include simultaneous determination of various species of As, Sb and Se in water. We have also developed SSNAA methods employing biochemical techniques for the simultaneous separation, preconcentration and characterization of metalloproteins and protein-bound trace element species of As, Br, Cd, Cu, Mn, Se, and Zn. We have developed methods for the simultaneous separation and characterization of organohalogen compounds in fish. An overview of the SSNAA methods being developed in our laboratory will be presented. (author)

  11. Application of micro-PIXE to fish life history analyses: trace element analysis of otoliths

    International Nuclear Information System (INIS)

    Elfman, M.; Limburg, K.E.; Kristiansson, P.; Malmqvist, K.; Pallon, J.

    1999-01-01

    Otoliths are biogenic, carbonate concretions which form part of the hearing/balance system in fishes. The radial growth of otoliths and the variation of trace elements along the radius appear to capture important aspects of fishes' environmental history. At the Lund Nuclear Microprobe Laboratory, we have begun to use Proton-Induced X-ray Emission spectroscopy (PIXE) for micro-elemental analysis of otoliths. The experimental procedure is discussed and a number of examples of what can be investigated are presented. In particular, movement of diadromous species (eel, menhaden, and anadromous brown trout) can be detected between fresh and brackish water by Sr/Ca ratio. This technique has also been used to identify fish that were raised in freshwater hatcheries and then released to brackish water (pike-perch example)

  12. Nanomolar Trace Metal Analysis of Copper at Gold Microband Arrays

    Science.gov (United States)

    Wahl, A.; Dawson, K.; Sassiat, N.; Quinn, A. J.; O'Riordan, A.

    2011-08-01

    This paper describes the fabrication and electrochemical characterization of gold microband electrode arrays designated as a highly sensitive sensor for trace metal detection of copper in drinking water samples. Gold microband electrodes have been routinely fabricated by standard photolithographic methods. Electrochemical characterization were conducted in 0.1 M H2SO4 and found to display characteristic gold oxide formation and reduction peaks. The advantages of gold microband electrodes as trace metal sensors over currently used methods have been investigated by employing under potential deposition anodic stripping voltammetry (UPD-ASV) in Cu2+ nanomolar concentrations. Linear correlations were observed for increasing Cu2+ concentrations from which the concentration of an unknown sample of drinking water was estimated. The results obtained for the estimation of the unknown trace copper concentration in drinking was in good agreement with expected values.

  13. Nanomolar Trace Metal Analysis of Copper at Gold Microband Arrays

    International Nuclear Information System (INIS)

    Wahl, A; Dawson, K; Sassiat, N; Quinn, A J; O'Riordan, A

    2011-01-01

    This paper describes the fabrication and electrochemical characterization of gold microband electrode arrays designated as a highly sensitive sensor for trace metal detection of copper in drinking water samples. Gold microband electrodes have been routinely fabricated by standard photolithographic methods. Electrochemical characterization were conducted in 0.1 M H 2 SO 4 and found to display characteristic gold oxide formation and reduction peaks. The advantages of gold microband electrodes as trace metal sensors over currently used methods have been investigated by employing under potential deposition anodic stripping voltammetry (UPD-ASV) in Cu 2+ nanomolar concentrations. Linear correlations were observed for increasing Cu 2+ concentrations from which the concentration of an unknown sample of drinking water was estimated. The results obtained for the estimation of the unknown trace copper concentration in drinking was in good agreement with expected values.

  14. Analysis of trace elements in chicken embryo cells

    International Nuclear Information System (INIS)

    Qiu Zhijun; Wang Jiqing; Guo Panlin; Li Xiaolin; Zhu Jieqing; Lu Rongrong

    2002-01-01

    A scanning proton microprobe (SPM) with high resolution and high sensitivity was applied to analyze trace elements in chicken embryo forebrain neutron cell and skeletal muscle myotube cell. The absorption of the two different cells to zinc ions, correlation of elements and trace elemental distributions in the cells were studied. The results indicate that the absorptive capacity of the chicken embryo forebrain neuron cell to zinc ions is larger than that of the chicken embryo skeletal muscle myotube cell, and the concentrations of intracellular trace elements such as Cr, Fe, Ni are explicitly higher. The correlations of elements such as S and Zn or Fe and Zn are positive, but the correlations of P and Ni or Cr and Fe are negative. From the maps of cellular elemental distribution the contents of the different elements are different in the intracellular parts, for example, the contents of the elements phosphorus, sulfur, potassium in the cell membranes are higher than that in the cells

  15. Instrumental neutron activation analysis in environmental research

    International Nuclear Information System (INIS)

    Bruin, M. de.

    1985-01-01

    The main characteristics of instrumental neutron activation analysis (INAA),relevant for environmental research and monitoring, was reviewed and discussed-sensitivity, suitable for detection of many toxic elements, the low risks of contamination of element loss, lack of matrix effects, lack of light element interference except for 24 Na, capability for multi-element determination, comparatively low costs. A detailed description of the IRI analysis system for routine INAA is given. The system is based on the single comparator method of standartization to take full advantage of multi-element without preparation and use the trace element standards. Zinc was used as mono element standard, the element concentrations are calculated on the basis of 65 Zn and 69m Zn-activities. The irradiations were carried out in a thermal neutron flux of 1.10 13 n/cm 2 .s. The gamma spectra is converted into element concentrations using a set of dedicated software, performing the following functions: spectrum analysis and interpretation, comparison and combination of the intermediate results from different decay times, generation of the final report, bookkeeping of the results obtained. The main applications of the INAA system mentioned are: identification of sources of heavy metal air pollution using air filters or biological indicators such as mosses, lichens, toe-nails, bird feathers, molusks and waterplants; and study of the uptake and translocation of heavy element in plants. Special attention was paid to mathematical techniques for a reliable interpretation of the element concentration patterns observed in sets of lichen samples. Future developments in INAA in environmental science are briefly mentioned

  16. Neutron activation analysis for environmental sample in Thailand

    International Nuclear Information System (INIS)

    Busamongkol, Arporn; Nouchpramool, Sunun; Bunprapob, Supamatthree; Sumitra, Tatchai

    2003-01-01

    Neutron Activation Analysis has been applied for the trace elements analysis in environmental samples. Thirty three samples of airborne particulate were collected every week at Ongkharak Nuclear Research Center (ONRC) during the period of June 1998 to March 1999. The Ti, I, Mg, Na, V, K, Cl, Al, Mn, Ca, As, Sm, Sb, Br, La, Ce, Th, Cr, Cs, Sc, Rb, Fe, Zn and Co were analyzed by Neutron Activation Analysis utilizing 2 MW TRIGA MARK III research reactor. The certified reference materials 1632a and 1633a from National Bureau of Standard were select as standard. (author)

  17. Reconstruction of baseline time-trace under changing environmental and operational conditions

    International Nuclear Information System (INIS)

    Aryan, P; Kotousov, A; Ng, C T; Wildy, S

    2016-01-01

    Compensation of changing environmental and operational conditions (EOC) is often necessary when using guided-wave based techniques for structural health monitoring in real-world applications. Many studies have demonstrated that the effect of changing EOC can mask damage to a degree that a critical defect might not be detected. Several effective strategies, specifically for compensating the temperature variations, have been developed in recent years. However, many other factors, such as changing humidity and boundary conditions or degradation of material properties, have not received much attention. This paper describes a practical method for reconstruction of the baseline time-trace corresponding to the current EOC. Thus, there is no need for differentiation or compensation procedures when using this method for damage diagnosis. It is based on 3D surface measurements of the velocity field near the actuator using laser vibrometry, in conjunction with high-fidelity finite element simulations of guided wave propagation in free from defects structure. To demonstrate the feasibility and efficiency of the proposed method we provide several examples of the reconstruction and damage detection. (paper)

  18. Reconstruction of baseline time-trace under changing environmental and operational conditions

    Science.gov (United States)

    Aryan, P.; Kotousov, A.; Ng, C. T.; Wildy, S.

    2016-03-01

    Compensation of changing environmental and operational conditions (EOC) is often necessary when using guided-wave based techniques for structural health monitoring in real-world applications. Many studies have demonstrated that the effect of changing EOC can mask damage to a degree that a critical defect might not be detected. Several effective strategies, specifically for compensating the temperature variations, have been developed in recent years. However, many other factors, such as changing humidity and boundary conditions or degradation of material properties, have not received much attention. This paper describes a practical method for reconstruction of the baseline time-trace corresponding to the current EOC. Thus, there is no need for differentiation or compensation procedures when using this method for damage diagnosis. It is based on 3D surface measurements of the velocity field near the actuator using laser vibrometry, in conjunction with high-fidelity finite element simulations of guided wave propagation in free from defects structure. To demonstrate the feasibility and efficiency of the proposed method we provide several examples of the reconstruction and damage detection.

  19. The use of stable isotopes to trace the impact of landfill gases on environmental waters

    International Nuclear Information System (INIS)

    Kennel, P.; Hendy, C.H.

    1997-01-01

    The process of anaerobic fermentation leading to methanogenisis in landfills produces isotopically depleted methane and isotopically enriched carbon dioxide. While the inflammability of methane is a recognised environmental hazard, the impact of the carbon dioxide produced has not been recognised. Unlike methane, the carbon dioxide is very soluble in waters it comes in contact with and unlike leachates it is not contained by the engineered structure of modern landfills. The carbon dioxide gas has the potential of dissolving in ground waters, lowering their pH and degrading their water quality. We have used up to +13 per thousand delta/sup 13/C values of the CO/sub 2/ gas to trace and quantify the effect of the enhanced P/sub CO2/ on groundwater. The downstream consequences of enhanced P/sub CO2/ on groundwater quality also depend on matrix lithology, being more significant for basaltic environments such as those typical of Auckland landfills than for the rhyolitic sands and gravels common in Waikato landfills. (author)

  20. Applied research on environmental pollution using INAA. A study on the environmental indicator analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Nak Bae; Lee, Gil Yong; Yoon, Yoon Yul; Chon, Sang Ki [Korea Institute of Geology Mining and Research, Taejon (Korea, Republic of)

    1995-08-01

    Among the many kinds of environmental indicator samples such as moss, lichen, pine needle, pine needle was selected as a bio-monitor and collected sample was divided two groups and one was washed with 1% hydrochloric acid to remove the elements deposited on surface. Trace elements in pine needle were analyzed by the decay time of each nuclide. Analytical accuracy was tested by analyzing NIST SRM 1575 pine needle. Results are follows: (1) Environmental indicator as a bio-monitor pine needle was selected. (2) The content difference of the trace elements between sampling period was monitored. And as content was varied with sampling time. (3) To monitor the influence of atmospheric deposition the surface of pine needle was washed with 1% hydrochloric acid. Therefore, As, Ce, La, Na, W, and Zn contents were decreased by washing. (4) Non-destructive INAA (Instrumental Neutron Activation Analysis) technique was developed for the determination of trace elements in environmental samples. (5) Analytical accuracy was tested by analyzing NIST SRM 1575 pine needle, and the accuracy was well agreed within 10% deviation. summarized. (author). 18 refs., 8 figs., 5 tabs.

  1. Screen-printed electro grafted electrode for trace uranium analysis

    Energy Technology Data Exchange (ETDEWEB)

    Betelu, St.; Vautrin-Ui, Ch.; Chausse, A. [Univ Evry Val Essonne, LAMBE, CNRS CEA, UMR 8587, F-91025 Evry, (France); Ly, J. [CEA, L3MR, Ctr Etud Saclay, DEN DANS DPC SECR, F-91191 Gif Sur Yvette, (France)

    2009-07-01

    This paper reports the interest of the novel 4-carboxyphenyl-grafted screen-printed electrodes (4-CP-SPEs) for sub-nano-molar analysis of uranium in water samples. Electrodes were easily prepared via electrochemically reduction of the corresponding diazonium salt. The stability of the grafted layer has been clearly demonstrated. Uranium detection was then achieved by immersing the grafted electrode into the sample solution, followed by the electrochemical measurement of adsorbed U(VI) by square wave voltammetry. Adsorption time was investigated so as to find the best compromise between analysis time, repeatability and reproducibility. Limit of detection and quantitation reached 7 * 10{sup -10} and 2 * 10{sup -9} mol L{sup -1} respectively. Moreover, interference study was conducted with Zn(II), Cd(II), Pb(II) and Cu(II); no major interference was established. 4-CP-SPEs were finally applied for uranium determination in estuarine water demonstrating the convenience of these electrodes for environmental analysis. (authors)

  2. Trace element analysis in silicon by accelerator SIMS

    Energy Technology Data Exchange (ETDEWEB)

    Ender, R.M.; Suter, M. [Eidgenoessische Technische Hochschule, Zurich (Switzerland); Doebeli, M.; Synal, H.A. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    The accelerator SIMS technique has been applied to Si samples implanted with different elements. It has been shown that concentrations of several trace elements can be analysed down to about 1 ppb in depth profiling mode. (author) 2 figs., 1 ref.

  3. Multivariate cluster analysis of some major and trace elements ...

    African Journals Online (AJOL)

    UFUOMA

    The chemical composition of water infiltrating ... Major and trace metals determined in soil and water from a ... The soil samples were air-dried at 29°C in a dust-free place for ... compact 3K5 X-ray generator (Ital IS Structures, Italy) was used for.

  4. Trace determination of 10 beta-lactam antibiotics in environmental and food samples by capillary liquid chromatography.

    Science.gov (United States)

    Bailón-Pérez, M I; García-Campaña, A M; del Olmo-Iruela, M; Gámiz-Gracia, L; Cruces-Blanco, C

    2009-11-20

    A sensitive and reliable method using capillary HPLC with UV-diode array detection (DAD) has been developed and validated for the trace determination of residues of 10 beta-lactam antibiotics of human and veterinary use, in milk, chicken meat and environmental water samples. The analytes included ampicillin, amoxicillin, penicillin V, penicillin G, cloxacillin, oxacillin, dicloxacillin, nafcillin, piperacillin and clavulanic acid. Legal levels are regulated by the EU Council regulation 2377/90 in animal edible tissues for these compounds. For food analysis, a solid-phase extraction (SPE) procedure consisting in a tandem of Oasis HLB and Alumina N cartridges was applied for off-line preconcentration and cleanup. For water analysis, the first step was only necessary. The limits of detection for the studied compounds were between 0.04-0.06 microg l(-1) for water samples and 0.80-1.40 microg l(-1) (or microg kg(-1)) in the case of foods derived from animals. Average recoveries for fortified samples at different concentration levels ranged between 82.9% and 98.2%, with relative standard deviations (RSDs) lower than 9%. The method showed the advantages of capillary HPLC for the detection of these widely applied antibiotics in different samples at very low concentration levels.

  5. Environmental trace analysis by means of supersensitive GC-IMS

    International Nuclear Information System (INIS)

    Leonhardt, J.W.

    1997-01-01

    The effective control of pollutants in ambient air requires their fast in situ identification and concentration determination of chemical compounds in the range of micrograms per m 3 . There are attempts to use conventional analytical techniques as portable GC and GC-MS. These systems are relatively expensive. A new supersensitive ion Mobility Sensor (IMS) was developed and checked by IUT Ltd, which meets the new demands. The use of tritium sources is an advantage in comparison with other IMS being equipped by nickel-63, the application of which is rather critical in respect of the radiation protection. On the other hand an integrated separation column allows to reduce interferences by matrix effects. The technical parameters of the IUT GC- IMS and some of its most important applications are briefly presented

  6. Environmental trace analysis by means of supersensitive GC-IMS

    Energy Technology Data Exchange (ETDEWEB)

    Leonhardt, J.W. [IUTLimited, Berlin, (Germany)

    1997-10-01

    The effective control of pollutants in ambient air requires their fast in situ identification and concentration determination of chemical compounds in the range of micrograms per m{sup 3}. There are attempts to use conventional analytical techniques as portable GC and GC-MS. These systems are relatively expensive. A new supersensitive ion Mobility Sensor (IMS) was developed and checked by IUT Ltd, which meets the new demands. The use of tritium sources is an advantage in comparison with other IMS being equipped by nickel-63, the application of which is rather critical in respect of the radiation protection. On the other hand an integrated separation column allows to reduce interferences by matrix effects. The technical parameters of the IUT GC- IMS and some of its most important applications are briefly presented 6 refs., 1 tab., 5 figs.

  7. Trace metals in corals--hind casting environmental chemical changes in the tropical Atlantic waters

    Science.gov (United States)

    Holmes, C. W.; Koenig, A.; Ridley, W. I.; Wilson, S. A.

    2002-12-01

    As corals grow, they secrete a calcareous skeleton with the aid of photosynthetic activity of endosymbiotic dinoflagellates (zooxanthellae). The rate of this secretion varies inter-annually. Entrapped with the carbonate are trace substances that record the chemistry of the surrounding ocean. Detailing changes in chemistry requires careful and very tedious high-resolution sampling. The advent of laser ablation inductive couple plasma/mass spectroscopy (LA-ICP/MS) circumvents this sampling problem. This method also permits a continuous scan of the entire coral skeleton. Another problem has been the lack of a carbonate standard which appears to be resolved with the creation of an artificial carbonate standard (USGS MAC-1). This standard is presently undergoing rigorous analysis, but preliminary results are very positive. The LA-ICP/MS data of three Atlantic corals reveals an intriguing distribution of trace metals and boron that may be related to climatic driven chemical changes during the last hundred years. The distribution of the trace metals appears to have an association with three climate signals: 1. the strength of the North Atlantic Oscillation (NAO), 2. the local effects of El Nino in the Florida region and 3. change in oceanic chemistry, possibly due to rising CO2. Aluminum and titanium levels vary with the strength of the NAO. The highest concentrations occur at the time of strong positive NOA when there is large amount of sediment transported off the deserts of North Africa. This relationship is particularly strong in the coral from the Cape Verde Islands. Along the eastern seaboard of the Atlantic, the relationship is not as pronounced but still observable. Nutrients and anthropogenic trace metals, such as zinc, lead, and mercury appear to correlate with local conditions and show a weak correspondence to the El Nino as it affects south Florida. Boron variation is directly related to the high-density bands of the corals. The long-term record of boron

  8. Intercomparison and determination of trace elements in urban dust by neutron activation analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Moon, Jong Hwa; Kim, Sun Ha; Park, Kwang Won; Kang, Sang Hun

    2000-01-01

    Trace elements in air samples artificially loaded on filters with urban dust and the bulk material of urban dust as an environmental sample were determined non-destructively using instrumental neutron activation analysis. Standard reference material (Urban Dust, SRM 1648) of the National Institute of Standard and Technology was used for the analytical quality control. The relative error for 37 elements was less than 15% and the standard deviation was less than 10%. 29 elements in the urban dust and 21 elements in the loaded filter sample were determined respectively. To evaluate the proficiency and reliability of the measurement, data intercomparison was performed and 39 analytical laboratories participated in the analysis using different analytical methods; neutron activation analysis, particle induced X-ray emission analysis, X-ray fluorescence analysis and atomic absorption spectrometry. Z-scores were calculated using the standard deviation of the laboratory's mean as target standard deviation, and a good result was obtained that the values fall between-1 and +1 except some elements. (author)

  9. Trace gas absorption spectroscopy using laser difference-frequency spectrometer for environmental application

    Science.gov (United States)

    Chen, W.; Cazier, F.; Boucher, D.; Tittel, F. K.; Davies, P. B.

    2001-01-01

    A widely tunable infrared spectrometer based on difference frequency generation (DFG) has been developed for organic trace gas detection by laser absorption spectroscopy. On-line measurements of concentration of various hydrocarbons, such as acetylene, benzene, and ethylene, were investigated using high-resolution DFG trace gas spectroscopy for highly sensitive detection.

  10. Application of ray-traced tropospheric slant delays to geodetic VLBI analysis

    Science.gov (United States)

    Hofmeister, Armin; Böhm, Johannes

    2017-08-01

    The correction of tropospheric influences via so-called path delays is critical for the analysis of observations from space geodetic techniques like the very long baseline interferometry (VLBI). In standard VLBI analysis, the a priori slant path delays are determined using the concept of zenith delays, mapping functions and gradients. The a priori use of ray-traced delays, i.e., tropospheric slant path delays determined with the technique of ray-tracing through the meteorological data of numerical weather models (NWM), serves as an alternative way of correcting the influences of the troposphere on the VLBI observations within the analysis. In the presented research, the application of ray-traced delays to the VLBI analysis of sessions in a time span of 16.5 years is investigated. Ray-traced delays have been determined with program RADIATE (see Hofmeister in Ph.D. thesis, Department of Geodesy and Geophysics, Faculty of Mathematics and Geoinformation, Technische Universität Wien. http://resolver.obvsg.at/urn:nbn:at:at-ubtuw:1-3444, 2016) utilizing meteorological data provided by NWM of the European Centre for Medium-Range Weather Forecasts (ECMWF). In comparison with a standard VLBI analysis, which includes the tropospheric gradient estimation, the application of the ray-traced delays to an analysis, which uses the same parameterization except for the a priori slant path delay handling and the used wet mapping factors for the zenith wet delay (ZWD) estimation, improves the baseline length repeatability (BLR) at 55.9% of the baselines at sub-mm level. If no tropospheric gradients are estimated within the compared analyses, 90.6% of all baselines benefit from the application of the ray-traced delays, which leads to an average improvement of the BLR of 1 mm. The effects of the ray-traced delays on the terrestrial reference frame are also investigated. A separate assessment of the RADIATE ray-traced delays is carried out by comparison to the ray-traced delays from the

  11. Ray-tracing toroidal axisymmetric devices. 1. theoretical analysis

    International Nuclear Information System (INIS)

    Cardinali, A.; Brambilla, M.

    1981-06-01

    Ray tracing technique for lower hybrid waves is used to obtain informations about accessibility, power deposition profiles and eventually electric field distribution. In the first part a critical discussion to establish the meaning and validity of this technique is presented, while in the second part of this work applications to small and to large, fat tokamaks are presented, which support and explain the theoretical arguments

  12. Neutron activation analysis as applied to instrumental analysis of trace elements from seawater

    International Nuclear Information System (INIS)

    Boniforti, R.; Moauro, A.; Madaro, M.

    1983-01-01

    Particulate matter collected from the coastal area delimited by the mouth of the river Volturno and the Sabaudia lake has been analyzed by instrumental neutron activation analysis for its content of twenty-two trace elements. The results for surface water and bottom water are reported separately, thus evidencing the effect of sampling depth on the concentration of many elements. The necessity of accurately 'cleaning' the filters before use is stressed

  13. [Determination and correlation analysis of trace elements in Boletus tomentipes].

    Science.gov (United States)

    Li, Tao; Wang, Yuan-zhong; Zhang, Ji; Zhao, Yan-li; Liu, Hong-gao

    2011-07-01

    The contents of eleven trace elements in Boletus tomentipes were determined by inductively coupled plasma atomic emission spectroscopy (ICP-AES). The results showed that the fruiting bodies of B. tomentipes were very rich in Mg and Fe (>100 mg x kg(-1)) and rich in Mn, Zn and Cu (>10 mg x kg(-1)). Cr, Pb, Ni, Cd, and As were relatively minor contents (0.1-10.0 mg x kg(-1)) of this species, while Hg occurred at the smallest content (< 0.1 mg x kg(-1)). Among the determined 11 trace elements, Zn-Cu had significantly positive correlation (r = 0.659, P < 0.05), whereas, Hg-As, Ni-Fe, and Zn-Mg had significantly negative correlation (r = -0.672, -0.610, -0.617, P < 0.05). This paper presented the trace elements properties of B. tomentipes, and is expected to be useful for exploitation and quality evaluation of this species.

  14. Polymers on the crime scene forensic analysis of polymeric trace evidence

    CERN Document Server

    Causin, Valerio

    2015-01-01

    This book approaches the analysis of forensic contact traces from a polymer science perspective. The development of characterization methods of new or unusual traces and the improvement of existing protocols is described. The book starts with a general introduction to polymers and the issues related to transfer, persistence and recovery of polymeric traces. The chapters present a distinctive feature of polymers, discussing how it can be measured, what the practical difficulties which can be encountered in the analysis, and how useful that information is for comparison or identification purposes. Practical tips for the realization of the forensic analyses are included.

  15. Cloud point extraction and spectrophotometric determination of mercury species at trace levels in environmental samples.

    Science.gov (United States)

    Ulusoy, Halil İbrahim; Gürkan, Ramazan; Ulusoy, Songül

    2012-01-15

    A new micelle-mediated separation and preconcentration method was developed for ultra-trace quantities of mercury ions prior to spectrophotometric determination. The method is based on cloud point extraction (CPE) of Hg(II) ions with polyethylene glycol tert-octylphenyl ether (Triton X-114) in the presence of chelating agents such as 1-(2-pyridylazo)-2-naphthol (PAN) and 4-(2-thiazolylazo) resorcinol (TAR). Hg(II) ions react with both PAN and TAR in a surfactant solution yielding a hydrophobic complex at pH 9.0 and 8.0, respectively. The phase separation was accomplished by centrifugation for 5 min at 3500 rpm. The calibration graphs obtained from Hg(II)-PAN and Hg(II)-TAR complexes were linear in the concentration ranges of 10-1000 μg L(-1) and 50-2500 μg L(-1) with detection limits of 1.65 and 14.5 μg L(-1), respectively. The relative standard deviations (RSDs) were 1.85% and 2.35% in determinations of 25 and 250 μg L(-1) Hg(II), respectively. The interference effect of several ions were studied and seen commonly present ions in water samples had no significantly effect on determination of Hg(II). The developed methods were successfully applied to determine mercury concentrations in environmental water samples. The accuracy and validity of the proposed methods were tested by means of five replicate analyses of the certified standard materials such as QC Metal LL3 (VWR, drinking water) and IAEA W-4 (NIST, simulated fresh water). Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Assessment of the environmental fate of cycloxaprid in flooded and anaerobic soils by radioisotopic tracing

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xuanqi; Xu, Xiaoyong; Li, Chao [Shanghai Key Laboratory of Chemical Biology, School of Pharmacy, East China, University of Science and Technology, Shanghai 200237 (China); Zhang, Hanxue; Fu, Qiuguo [Institute of Nuclear Agricultural Sciences, Zhejiang University, Hangzhou 310029 (China); Shao, Xusheng [Shanghai Key Laboratory of Chemical Biology, School of Pharmacy, East China, University of Science and Technology, Shanghai 200237 (China); Ye, Qingfu, E-mail: qfye@zju.edu.cn [Institute of Nuclear Agricultural Sciences, Zhejiang University, Hangzhou 310029 (China); Li, Zhong, E-mail: lizhong@ecust.edu.cn [Shanghai Key Laboratory of Chemical Biology, School of Pharmacy, East China, University of Science and Technology, Shanghai 200237 (China)

    2016-02-01

    Cycloxaprid (CYC) is a novel broad-spectrum neonicotinoid insecticide that has been developed for agricultural pest control. The fate of the {sup 14}C-labeled racemic and enantio-pure CYC isomers in flooded and anaerobic soil was investigated using radioisotope tracing techniques. After 100 d of incubation, only a minor portion (< 1%) of the applied CYC isomers is mineralized by each of the four tested soil types. The fraction of initially applied radioactive CYC dissipated into the bound or non-extractable residues (BR) increases with increase in the length of the incubation period, reaching up to 53.0–81.6%. The dissipation of the CYC through mineralization or formation of BR is strongly influenced by soil properties, such as humic content, pH value, and retained microbial activity. Amongst the soils studied, the fluvio-marine yellow loamy soil displayed the highest tendency to mineralize CYC while the coastal saline soil exhibited the strongest tendency to form BR. The observation that the water phase retained the large portion(> 60%) of the radioactivity attributed to the total extractable residue suggested that under the experimental condition, the initially applied {sup 14}C-labeled CYC residues were readily available for leaching or offsite transport. Additionally, no enantiomer-specific behaviors are observed. The results from this study provide a framework for assessing the environmental impact resulting from the use of this pesticide. - Highlights: • Only a minor portion (<1%) of the applied CYC was mineralized. • The bound residue increased over time, reaching up to 53.0-81.6%. • CYC residues were readily available for leaching. • No enantiomer-specific behaviors were observed.

  17. Particle induced X-ray emission for quantitative trace-element analysis using the Eindhoven cyclotron

    International Nuclear Information System (INIS)

    Kivits, H.

    1980-01-01

    Development of a multi-elemental trace analysis technique using PIXE (Particle Induced X-ray Emission), was started almost five years ago at the Eindhoven University of Technology, in the Cyclotron Applications Group of the Physics Department. The aim of the work presented is to improve the quantitative aspects of trace-element analysis with PIXE, as well as versatility, speed and simplicity. (Auth.)

  18. Determination of trace amounts of rare earth elements in various environmental samples by spark source mass spectrography

    International Nuclear Information System (INIS)

    Sugimae, Akiyoshi

    1978-01-01

    A chemical concentration-mass spectrographic procedure was described for the determination of trace amounts of rare earth elements in various environmental samples: airborne particulate matter, dustfall, soil and so forth. A 0.5 to 1 gram of sample material was decomposed by fusion with sodium carbonate. The silica dehydrated in the usual way was filtered off and the filtrate from the silica was then treated with ammonium hydroxide to precipitate the rare earth elements. After ignition of the precipitate, two ml of internal standard solution containing 20 μg/ml of silver were added and the mixture was then evaporated to dryness. The residue was mixed with an equal amount of graphite powder and then pressed into electrodes. Relative sensitivity coefficients (Ag=1.0) were determined by using Spex Mix and U. S. Geological Survey rock standard G-2. U. S. Geological Survey rock standard GSP-1 and N.B.S. coal fly ash SRM 1633 were analysed to evaluate the accuracy of the proposed method. Comparison of the mass spectral values with literature ones indicated a good agreement. The coefficient of variation obtained by replicate analysis of SRM 1633 was better than 25%. The proposed method was applied to the determination of rare earth elements in airborne particulate matter and dustfall collected on polystyrene filter and in dustjars, respectively. Results for the rare earth elements in the blank of glass fiber filter which was widely used for the collection of airborne particulate matter were also presented. (auth.)

  19. Concentration of 24 Trace Elements in Human Heart Tissue Determined by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wester, P O

    1964-06-15

    By means of neutron-activation analysis, human heart tissue from autopsy of 20 victims of traumatic accidents has been investigated with respect to the concentration of 24 different trace elements. A recently developed ion-exchange technique combined with gamma spectrometry has been used, which permits simultaneous determination of a large number of trace elements. The following trace elements have been determined quantitatively: Ag, As, Au, Ba, Br; Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Pt, Rb, Sb, Se, Se, Sm, Zn, W. In some heart samples, Hf and Os were determined qualitatively. The mean and standard deviation are given for the elements Cu, Fe, Se and Zn, Since none of the other quantitatively determined trace elements were normally distributed, the median is given as the central value. When possible, comparisons with values from other investigations have been made. No marked differences in the trace-element concentrations with age or sex could be detected.

  20. Concentration of 24 Trace Elements in Human Heart Tissue Determined by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Wester, P.O.

    1964-06-01

    By means of neutron-activation analysis, human heart tissue from autopsy of 20 victims of traumatic accidents has been investigated with respect to the concentration of 24 different trace elements. A recently developed ion-exchange technique combined with gamma spectrometry has been used, which permits simultaneous determination of a large number of trace elements. The following trace elements have been determined quantitatively: Ag, As, Au, Ba, Br; Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Pt, Rb, Sb, Se, Se, Sm, Zn, W. In some heart samples, Hf and Os were determined qualitatively. The mean and standard deviation are given for the elements Cu, Fe, Se and Zn, Since none of the other quantitatively determined trace elements were normally distributed, the median is given as the central value. When possible, comparisons with values from other investigations have been made. No marked differences in the trace-element concentrations with age or sex could be detected

  1. Visualizing data for environmental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Benson, J.

    1997-04-01

    The Environmental Restoration Project at Los Alamos National Laboratory (LANL) has over 11,000 sampling locations in a 44 square mile area. The sample analyses contain raw analytical chemistry values for over 2,300 analytes and compounds used to define and remediate contaminated areas at LANL. The data consist of 2.5 million records in an oracle database. Maps are often used to visualize the data. Problems arise when a client specifies a particular kind of map without fully understanding the limitations of the data or the map. The ability of maps to convey information is dependent on many factors, though all maps are data dependent. The quantity, spatial distribution, and numerical range of the data can limit use with certain kinds of maps. To address these issues and educate the clients, several types of statistical maps (e.g., choropleth, isarithm, and graduated symbol such as bubble and spike) used for environmental analysis were chosen to show the advantages, disadvantages, and data limitations of each. By examining both the complexity of the analytical data and the limitations of the map type, it is possible to consider how reality has been transformed through the map, and if that transformation accurately conveys the information present.

  2. Visualizing data for environmental analysis

    International Nuclear Information System (INIS)

    Benson, J.

    1997-01-01

    The Environmental Restoration Project at Los Alamos National Laboratory (LANL) has over 11,000 sampling locations in a 44 square mile area. The sample analyses contain raw analytical chemistry values for over 2,300 analytes and compounds used to define and remediate contaminated areas at LANL. The data consist of 2.5 million records in an oracle database. Maps are often used to visualize the data. Problems arise when a client specifies a particular kind of map without fully understanding the limitations of the data or the map. The ability of maps to convey information is dependent on many factors, though all maps are data dependent. The quantity, spatial distribution, and numerical range of the data can limit use with certain kinds of maps. To address these issues and educate the clients, several types of statistical maps (e.g., choropleth, isarithm, and graduated symbol such as bubble and spike) used for environmental analysis were chosen to show the advantages, disadvantages, and data limitations of each. By examining both the complexity of the analytical data and the limitations of the map type, it is possible to consider how reality has been transformed through the map, and if that transformation accurately conveys the information present

  3. Analysis of trace elements in serum from human eating irradiated food

    International Nuclear Information System (INIS)

    Huang Zongzhi; Zhou Hongdi; Chen Shijie; Gao Sumei

    1987-01-01

    A method of trace element analysis by Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AEC) in serum from human eating food preserved by irradiation is described. Trace element analysis in human serum is one of the research projects concerning the wholesomeness. 78 serum samples of the human eating food preserved by irradiation were collected. After ashing and solving ICP-AES analysis of serum is performed for detecting 12 trace elements in specimen solution. The detection limitations are in the range of 10 -2 - 10 -3 ppm for differemt elements. The recoveries of elements are over 73%. Concentrations of 12 trace elements in 78 human serum has been calculated with F and t tests at PDP 11/70 computer and it was concluded that there is no significant difference between testing group and control group

  4. Environmental impact of some trace elements emission from the work environment of Atbara Cement Factory and Atbara Railway Foundry

    Energy Technology Data Exchange (ETDEWEB)

    Nimir, S A.M. [University of Khartoum, Faculty of Education, Department of Chemistry, Khartoum (Sudan)

    2006-06-15

    This work was performed to evaluate the chemical pollution level by some trace elements at the work environment of Atbara Cement Factory (ACF) and Atbara Railway Foundry (ARF). Samples of soil and air were collected from the two sites study, ACF and ARF. To assess the environmental impact of these industrial complexes, the samples were collected from sites expected to be free from industrial emission to serve as control. Plant samples were also collected from (ACF) and the control site. The samples were analyzed and the concentrations of K, Na, Mn, Fe, Cu, Zu and Pb were determined using three analytical techniques: Atomic absorption spectroscopy (AAS), X-ray fluorescence (X RF), and flame emission photometry (FEP). Soil samples were chemically fractionated using separation methods and the solutions were analyzed using AAS methods and FEP to determine the chemical form of the elements. The quality of the data was achieved through the analysis of certified reference materials. The results of this study were compared with previous literature. The data were treated by calculating enrichment factor and statistically by multivariate analysis such as, principle component analysis and cluster analysis. The findings of the study were concluded as follows. The effect of emission from both sites is very clear when the concentrations of the studied trace elements in soil and air samples are compared with the respective concentrations at the control site. Higher values of these elements are found at ARF and slightly high at ACF. The elements which can be attributed to industrial emission are noticeably higher at ARF, for example Cu is forty times as higher as compared to the control site. While Zn is slightly high and Pb is very high. The same remarks are further confirmed by enrichment factor calculation. For soil samples enrichment factor was obtained for two groups of elements, the enriched group includes the elements Pb, Cu and Zn which have enrichment factors higher in

  5. Environmental impact of some trace elements emission from the work environment of Atbara Cement Factory and Atbara Railway Foundry

    International Nuclear Information System (INIS)

    Nimir, S.A.M.

    2006-06-01

    This work was performed to evaluate the chemical pollution level by some trace elements at the work environment of Atbara Cement Factory (ACF) and Atbara Railway Foundry (ARF). Samples of soil and air were collected from the two sites study, ACF and ARF. To assess the environmental impact of these industrial complexes, the samples were collected from sites expected to be free from industrial emission to serve as control. Plant samples were also collected from (ACF) and the control site. The samples were analyzed and the concentrations of K, Na, Mn, Fe, Cu, Zu and Pb were determined using three analytical techniques: Atomic absorption spectroscopy (AAS), X-ray fluorescence (X RF), and flame emission photometry (FEP). Soil samples were chemically fractionated using separation methods and the solutions were analyzed using AAS methods and FEP to determine the chemical form of the elements. The quality of the data was achieved through the analysis of certified reference materials. The results of this study were compared with previous literature. The data were treated by calculating enrichment factor and statistically by multivariate analysis such as, principle component analysis and cluster analysis. The findings of the study were concluded as follows. The effect of emission from both sites is very clear when the concentrations of the studied trace elements in soil and air samples are compared with the respective concentrations at the control site. Higher values of these elements are found at ARF and slightly high at ACF. The elements which can be attributed to industrial emission are noticeably higher at ARF, for example Cu is forty times as higher as compared to the control site. While Zn is slightly high and Pb is very high. The same remarks are further confirmed by enrichment factor calculation. For soil samples enrichment factor was obtained for two groups of elements, the enriched group includes the elements Pb, Cu and Zn which have enrichment factors higher in

  6. Reference material for trace analysis by radioanalytical methods: Bowen's Kale

    International Nuclear Information System (INIS)

    Wainerdi, R.E.

    1979-01-01

    A fairly large volume of published data on 'Bowen's Kale' has been examined critically in order to develop recommendations for the use of this preparation as a 'reference material' in the standardisation and evaluation of the reliability of analytical procedures. Values are now recommended for the contents of twelve elements present in major to trace concentrations in 'Bowen's Kale'. 'Indicated values' for another 16 elements are provided. Values for 15 more elements are listed with no recommendation. The criteria adopted in categorising elements into these groups are discussed. (author)

  7. X-ray fluorescent analysis of iodin traces in urine

    International Nuclear Information System (INIS)

    Mikhajlov, I.F.; Baturin, A.A.; Mikhajlov, A.I.; Borisova, S.S.; Reshetnyak, M.V.; Shlyakhova, N.V.; Budrejko, E.A.; Galata, D.I.

    2015-01-01

    Using XFA method, determination of iodine concentration in urine for 35 children of 10-15 with endocrine pathology (delay of sexual development, diffuse goiter, obesity) and 10 practically healthy children being observed under conditions of the consultative polyclinic and the department of endocrinology of SI ''ISHCJ NAMSU''. The proposed optimized XFA method allows by 1-2 orders increasing detection sensitivity for micro-elements measurements in biology objects and attaining the iodine trace contents in urine in the range from 50 to 200 gg/dm 3

  8. Neutron activation analysis of trace elements in Japanese hormesis cosmetics

    International Nuclear Information System (INIS)

    Furuta, E.; Nakahara, H.; Hatsukawa, Y.; Matsue, H.; Sakane, H.

    2008-01-01

    In Japan, cosmetics claiming hormesis effect are available through Internet. Although these cosmetics show the contents, they never mention the minor elements and radioactive sources. The existence of radioisotopes, however, was observed by measurements of the gamma-rays with a HPGe detector. In this study, in order to clarify the contents of trace elements, the hormesis cosmetics including radioactive sources were analyzed using INAA, PGAA and NAA with multiple gamma-ray detection (NAAMG). Nineteen elements were analyzed quantitatively in hormesis cosmetics by INAA, PGAA and NAAMG and 16 elements were detected qualitatively by SEM-EPMA. (author)

  9. Major and trace elements assessment in sediment from Ituparanga reservoir, by activation analysis and ICP OES

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Sharlleny A., E-mail: sharllenya@cetesbnet.sp.gov.br [Companhia de Tecnologia de Saneamento Ambiental (CETESB), Sao Paulo, SP (Brazil). Lab. de Quimica Inorganica; Bevilacqua, Jose Eduardo [Companhia de Tecnologia de Saneamento Ambiental (CETESB), Sao Paulo, SP (Brazil). Diretoria de Tecnologia, Qualidade e Avaliacao Ambiental; Favaro, Deborah I.T., E-mail: defavaro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Lab. de Analise por Ativacao Neutronica

    2011-07-01

    The Ituparanga reservoir was built to generate electric power by the LIGHT Company and started its operation in 1912. It is fed by the Una, Sorocamirim and Sorocabucu rivers. This reservoir supplies water to a population of 600.000. This water system is affected by irregular soil occupation and urban development which has caught CETESB's (Environmental Company of Sao Paulo State) attention. In this study four geo-referenced sampling points were used and bottom sediment samples were collected. The sediment samples were dried at 400 deg C, ground in an agate mortar, sieved (200 mesh) and again homogenized. The instrumental neutron activation analysis was applied to the sediment samples in order to determine some major elements (Fe, K and Na), trace (As, Ba, Br, Co, Cr, Cs, Hf, Rb, Sb, Sc, Ta, Tb, Th, U and Zn) and rare earth (Ce, Eu, La, Lu, Nd, Sm, Tb and Yb) elements. By using ICP OES metals determination for Cd, Cr, Cu, Pb and Ni was undertaken after digestion procedure according to the 3051 method from US EPA. The methodology validation for precision and accuracy was carried out by reference material analyses. For metals Cd, Cr, Cu, Pb and Ni the concentration values were compared to the oriented values from Environmental Canada (TEL and PEL). The Enrichment Factor (EF) was calculated for sediment contamination assessment. (author)

  10. Major and trace elements assessment in sediment from Ituparanga reservoir, by activation analysis and ICP OES

    International Nuclear Information System (INIS)

    Silva, Sharlleny A.; Bevilacqua, Jose Eduardo; Favaro, Deborah I.T.

    2011-01-01

    The Ituparanga reservoir was built to generate electric power by the LIGHT Company and started its operation in 1912. It is fed by the Una, Sorocamirim and Sorocabucu rivers. This reservoir supplies water to a population of 600.000. This water system is affected by irregular soil occupation and urban development which has caught CETESB's (Environmental Company of Sao Paulo State) attention. In this study four geo-referenced sampling points were used and bottom sediment samples were collected. The sediment samples were dried at 400 deg C, ground in an agate mortar, sieved (200 mesh) and again homogenized. The instrumental neutron activation analysis was applied to the sediment samples in order to determine some major elements (Fe, K and Na), trace (As, Ba, Br, Co, Cr, Cs, Hf, Rb, Sb, Sc, Ta, Tb, Th, U and Zn) and rare earth (Ce, Eu, La, Lu, Nd, Sm, Tb and Yb) elements. By using ICP OES metals determination for Cd, Cr, Cu, Pb and Ni was undertaken after digestion procedure according to the 3051 method from US EPA. The methodology validation for precision and accuracy was carried out by reference material analyses. For metals Cd, Cr, Cu, Pb and Ni the concentration values were compared to the oriented values from Environmental Canada (TEL and PEL). The Enrichment Factor (EF) was calculated for sediment contamination assessment. (author)

  11. Dendro-analysis: the study of trace elements in tree rings

    International Nuclear Information System (INIS)

    Gilboy, W.B.; Tout, R.E.; Spyrou, N.M.

    1976-01-01

    In attempts to study environmental contamination over long time scales into the past, the levels of trace and minor elements in individual tree rings have been measured using instrumental neutron activation analysis. Most measurements so far have been done on elm tree samples which are widely available due to a current epidemic of Dutch Elm disease in southern England. Samples taken from every growth ring were individually activated for ten minutes in a thermal neutron flux of 1.5 x 10 12 n cm -2 sec -1 in the 100 kW London University research reactor. The activated samples were counted for ten minutes on a 42 cm 3 Ge(Li) gamma ray detector. These procedures enabled the following radioisotopes to be monitored for a large number of samples: 19 0, 24 Na, 27 Mg, 28 Al, 38 Cl, 42 K, 49 Ca, 56 Mn, 66 Cu, 80 Br, 87 /sup m/Sr, 41 Ar, 128 I, 139 Ba. Some of the above isotopes show striking systematic variations both from ring to ring in a radial direction, and also around individual rings. Results are described in detail for samples taken from trees grown in various locations and assesses the potential of this technique for studying past environmental conditions

  12. Using portable X-ray fluorescence spectrometry and GIS to assess environmental risk and identify sources of trace metals in soils of peri-urban areas in the Yangtze Delta region, China.

    Science.gov (United States)

    Ran, Jing; Wang, Dejian; Wang, Can; Zhang, Gang; Yao, Lipeng

    2014-08-01

    Portable X-ray fluorescence (PXRF) spectrometry may be very suitable for a fast and effective environmental assessment and source identification of trace metals in soils. In this study, topsoils (0-10 cm) at 139 sites were in situ scanned for total trace metals (Cr, Cu, Ni, Pb and Zn) and arsenic concentrations by PXRF in a typical town in Yangtze Delta region of Jiangsu province, China. To validate the utility of PXRF, 53 samples were collected from the scanning sites for the determination of selected trace metals using conventional methods. Based on trace metal concentrations detected by in situ PXRF, the contamination extent and sources of trace metals were studied via geo-accumulation index, multivariate analysis and geostatistics. The trace metal concentrations determined by PXRF were similar to those obtained via conventional chemical analysis. The median concentration of As, Cr, Cu, Ni, Pb and Zn in soils were 10.8, 56.4, 41.5, 43.5, 33.5, and 77.7 mg kg(-1), respectively. The distribution patterns of Cr, Cu, Ni, Pb, and Zn were mostly affected by anthropogenic sources, while As was mainly derived from lithogenic sources. Overall, PXRF has been successfully applied to contamination assessment and source identification of trace metals in soils.

  13. Analysis of an XADS Target with the System Code TRACE

    International Nuclear Information System (INIS)

    Jaeger, Wadim; Sanchez Espinoza, Victor H.; Feng, Bo

    2008-01-01

    Accelerator-driven systems (ADS) present an option to reduce the radioactive waste of the nuclear industry. The experimental Accelerator-Driven System (XADS) has been designed to investigate the feasibility of using ADS on an industrial scale to burn minor actinides. The target section lies in the middle of the subcritical core and is bombarded by a proton beam to produce spallation neutrons. The thermal energy produced from this reaction requires a heat removal system for the target section. The target is cooled by liquid lead-bismuth-eutectics (LBE) in the primary system which in turn transfers the heat via a heat exchanger (HX) to the secondary coolant, Diphyl THT (DTHT), a synthetic diathermic fluid. Since this design is still in development, a detailed investigation of the system is necessary to evaluate the behavior during normal and transient operations. Due to the lack of experimental facilities and data for ADS, the analyses are mostly done using thermal hydraulic codes. In addition to evaluating the thermal hydraulics of the XADS, this paper also benchmarks a new code developed by the NRC, TRACE, against other established codes. The events used in this study are beam power switch-on/off transients and a loss of heat sink accident. The obtained results from TRACE were in good agreement with the results of various other codes. (authors)

  14. Trace elements in precious and common opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1997-01-01

    Neutron activation analysis (NAA) was used to determine the concentration of trace elements in 44 precious and 52 common opals sampled from a number of recognised fields within Australia. The purpose of this study was to determine if precious and common opals of the same colour and location have the same or a different trace element profile. Similar numbers of black, white and grey samples were studied in each case. In most cases, common opals had a significantly higher concentration of certain trace elements when compared with precious opals. (author)

  15. Trace element evaluation of different varieties of chewing gum by radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Zaidi, J.H.; Arif, M.; Fatima, I.; Ahmad, S.; Qureshi, I.H.

    2000-01-01

    Extensive use of chewing gums, by children in particular, entails the evaluation of trace element contents in them. Radiochemical neutron activation analysis (RNAA) was successfully employed to determine the concentration of 35 trace elements (essential, toxic and nonessential) in eight different brands of chewing gum generally consumed in Rawalpindi/Islamabad area. Comparison of trace element data of our work with literature has been presented. None of the elements detected in the brands of chewing gum examined was found to be present at a level representing a substantial contribution to the total dietary intake of the element. (author)

  16. Trace element determination study in human hair by neutron activation analysis

    International Nuclear Information System (INIS)

    Frazao, Selma Violato

    2008-01-01

    Human hair analysis studies have been subject of continuous interest due to the fact that they can be used as an important tool to evaluate trace element levels in the human body. These determinations have been carried out to use hair for environmental and occupational monitoring, to identify intoxication or poisoning by toxic metals, to assess nutritional status, to diagnose and to prevent diseases and in forensic sciences. Although hair analysis presents several advantages over other human tissue or fluid analyses, such as organ tissue, blood, urine and saliva, there are some controversies regarding the use of hair analysis data. These controversies arise from the fact that it is difficult to establish reliable reference values for trace elements in hair. The purpose of this study was to evaluate the factors that affect element concentrations in hair samples from a population considered healthy and residing in the Sao Paulo metropolitan area. The collected human head hair was cut in small pieces, washed, dried and analyzed by neutron activation analysis (NAA). Aliquots of hair samples and synthetic elemental standards were irradiated at the IEA-R1 nuclear research reactor for 16 h under a thermal neutron flux of about 5x10 12 n cm -2 s -1 for As, Br, Ca, Co, Cr, Cs, Cu, Fe, K, La, Na, Sb, Sc, Se and Zn determinations. The induced gamma activities of the standards and samples were measured using a gamma ray spectrometer coupled to an hiperpure Ge detector. For quality control of the results, IAEA- 85 Human Hair and INCT-TL-1 Tea Leaves certified reference materials (CRMs) were analyzed. Results obtained in these CRMs presented for most of elements, good agreement with the values of the certificates (relative errors less than 10%) and good precision (variation coefficients less than 13.6%). Results of replicate hair sample analysis showed good reproducibility indicating homogeneity of the prepared sample. Results obtained in the analyses of dyed and non-dyed hair

  17. Effect of sample digestion, air filter contamination, and post-adsorption on the analysis of trace elements in air particulate matter

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiao Jin [Department of Environment and Climate Change, Environmental Forensic and Analytical Science Section, New South Wales (Australia); Department of Applied Chemistry, College of Chemical Engineering, Beijing University of Chemical Technology, Beijing (China); Wan, Pingyu [Department of Applied Chemistry, College of Chemical Engineering, Beijing University of Chemical Technology, Beijing (China); Foley, Roy [Department of Environment and Climate Change, Environmental Forensic and Analytical Science Section, New South Wales (Australia)

    2012-11-15

    Inductively coupled plasma atomic emission spectrometry and inductively coupled plasma MS are the major analytical tools for trace elements in environmental matrices, however, the underestimate of certain trace elements in analysis of air particulate matter by these two techniques has long been observed. This has been attributed to incomplete sample digestion. Here, we demonstrate that the combined effects of sample digestion, air filter impurities, and post-adsorption of the analytes contribute to the interference of the analysis. Particular attention should be paid to post-adsorption of analytes onto air filters after acid digestion. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  18. Effect of sample digestion, air filter contamination, and post-adsorption on the analysis of trace elements in air particulate matter

    International Nuclear Information System (INIS)

    Yang, Xiao Jin; Wan, Pingyu; Foley, Roy

    2012-01-01

    Inductively coupled plasma atomic emission spectrometry and inductively coupled plasma MS are the major analytical tools for trace elements in environmental matrices, however, the underestimate of certain trace elements in analysis of air particulate matter by these two techniques has long been observed. This has been attributed to incomplete sample digestion. Here, we demonstrate that the combined effects of sample digestion, air filter impurities, and post-adsorption of the analytes contribute to the interference of the analysis. Particular attention should be paid to post-adsorption of analytes onto air filters after acid digestion. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  19. Metal and trace element assessment of sediments from Guarapiranga reservoir, Sao Paulo State, by neutron activation analysis

    International Nuclear Information System (INIS)

    Guimaraes, Guilherme M.; Favaro, Deborah I.T.; Franklin, Robson L.; Ferreira, Francisco J.; Bevilacqua, Jose E.

    2009-01-01

    Guarapiranga Reservoir is extremely important due to the fact that it is one of the main water reservoirs for South America's largest city, Sao Paulo, Brazil. Guarapiranga Basin is located within the Metropolitan Region of Sao Paulo - RMSP, and occupies an area of approximately 630 km 2 , and the reservoir itself is located in the northern part of the basin occupying approximately 26 km 2 . This reservoir is characterized by environmental impacts from urban invasion, industrial and sewage wastes, all of which seriously affect its water quality. Due to its vulnerability CETESB (Environmental Control Agency of the Sao Paulo State) regularly monitors the contamination levels of waters and once a year sediment samples. In order to better understand geochemical and environmental processes and their possible changes due to anthropogenic activities trace metals analyses and their distribution in sediments are commonly undertaken. The present study reports results concerning the distribution of some major (Fe, K and Na), trace (As, Ba, Br, Co, Cr, Cs, Hf, Hg, Rb, Sb, Sc, Ta, Tb, Th, U and Zn) and rare earth (Ce, Eu, La, Lu, Nd, Sm, Tb and Yb) elements in sediments from the Guarapiranga Reservoir. Multielementar analysis was carried out by instrumental neutron activation analysis (INAA). Multielemental concentrations in the sediment samples were compared to NASC (North American Shale Composite) values. The concentration values for metals As, Cr and Zn in the sediment samples were compared to the Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL values) and adopted by CETESB. (author)

  20. Trends and applications of integrated automated ultra-trace sample handling and analysis (T9)

    International Nuclear Information System (INIS)

    Kingston, H.M.S.; Ye Han; Stewart, L.; Link, D.

    2002-01-01

    Full text: Automated analysis, sub-ppt detection limits, and the trend toward speciated analysis (rather than just elemental analysis) force the innovation of sophisticated and integrated sample preparation and analysis techniques. Traditionally, the ability to handle samples at ppt and sub-ppt levels has been limited to clean laboratories and special sample handling techniques and equipment. The world of sample handling has passed a threshold where older or 'old fashioned' traditional techniques no longer provide the ability to see the sample due to the influence of the analytical blank and the fragile nature of the analyte. When samples require decomposition, extraction, separation and manipulation, application of newer more sophisticated sample handling systems are emerging that enable ultra-trace analysis and species manipulation. In addition, new instrumentation has emerged which integrate sample preparation and analysis to enable on-line near real-time analysis. Examples of those newer sample-handling methods will be discussed and current examples provided as alternatives to traditional sample handling. Two new techniques applying ultra-trace microwave energy enhanced sample handling have been developed that permit sample separation and refinement while performing species manipulation during decomposition. A demonstration, that applies to semiconductor materials, will be presented. Next, a new approach to the old problem of sample evaporation without losses will be demonstrated that is capable of retaining all elements and species tested. Both of those methods require microwave energy manipulation in specialized systems and are not accessible through convection, conduction, or other traditional energy applications. A new automated integrated method for handling samples for ultra-trace analysis has been developed. An on-line near real-time measurement system will be described that enables many new automated sample handling and measurement capabilities. This

  1. Santos estuarine sediments, Brazil - metal and trace element assessment by neutron activation analysis

    International Nuclear Information System (INIS)

    Amorim, Eduardo P.; Favaro, Deborah I.T.; Berbel, Glaucia; Braga, Elisabete S.

    2009-01-01

    The Santos estuary system is an intricate pattern of tidal channels and small rivers originating from the adjacent Pre-Cambrian slopes. These two major estuaries share a common area in the upper portion of the region which interacts with each other. The largest harbor in Latin America is located at the eastern outlet of the Santos estuary. This intricate and sensitive ecosystem is highly susceptible to human impact from industrial activities, urban sewage and polluted solid wastes disposal. Due to its high vulnerability CETESB (Environmental Control Agency of the Sao Paulo State) sporadically monitors the contamination levels of water, sediment and marine organisms in this region. The present study reports results concerning the distribution of some major, trace and rare earth elements in the Santos estuarine marine sediments. Thirty two bottom sediment samples (SS0601 to SS0616 (summer) and SW0601 to SW0616 (winter) were collected in this estuary, including regions of Sao Vicente, Santos, Cubatao and Vicente de Carvalho, by a vanVeen sampler in the summer and winter of 2006. Multielemental analysis was carried out by instrumental neutron activation analysis (INAA). The concentration values obtained for As and metals Cr and Zn in the sediment samples were compared to Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL values) and are adopted by CETESB. (author)

  2. Santos estuarine sediments, Brazil - metal and trace element assessment by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Amorim, Eduardo P.; Favaro, Deborah I.T., E-mail: ducamorim@yahoo.com.b, E-mail: defavaro@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP) Sao Paulo, SP (Brazil); Berbel, Glaucia; Braga, Elisabete S., E-mail: edsbraga@usp.b [Universidade de Sao Paulo (USP), SP (Brazil). Inst. Oceanografico. Lab. de Nutrientes, Micronutrientes e Tracos nos Oceanos (LABNUT)

    2009-07-01

    The Santos estuary system is an intricate pattern of tidal channels and small rivers originating from the adjacent Pre-Cambrian slopes. These two major estuaries share a common area in the upper portion of the region which interacts with each other. The largest harbor in Latin America is located at the eastern outlet of the Santos estuary. This intricate and sensitive ecosystem is highly susceptible to human impact from industrial activities, urban sewage and polluted solid wastes disposal. Due to its high vulnerability CETESB (Environmental Control Agency of the Sao Paulo State) sporadically monitors the contamination levels of water, sediment and marine organisms in this region. The present study reports results concerning the distribution of some major, trace and rare earth elements in the Santos estuarine marine sediments. Thirty two bottom sediment samples (SS0601 to SS0616 (summer) and SW0601 to SW0616 (winter) were collected in this estuary, including regions of Sao Vicente, Santos, Cubatao and Vicente de Carvalho, by a vanVeen sampler in the summer and winter of 2006. Multielemental analysis was carried out by instrumental neutron activation analysis (INAA). The concentration values obtained for As and metals Cr and Zn in the sediment samples were compared to Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL values) and are adopted by CETESB. (author)

  3. Cadmium (II) imprinted 3-mercaptopropyltrimethoxysilane coated stir bar for selective extraction of trace cadmium from environmental water samples followed by inductively coupled plasma mass spectrometry detection

    International Nuclear Information System (INIS)

    Zhang Nan; Hu Bin

    2012-01-01

    analysis of trace Cd(II) in rain water, East Lake and Yangtze River water. To validate the proposed method, certified reference material of GSBZ 50009-88 environmental water was analyzed and the determined value is in a good agreement with the certified value. The developed method is rapid, selective, sensitive and applicable for the analysis of trace Cd(II) in environmental water samples.

  4. Cadmium (II) imprinted 3-mercaptopropyltrimethoxysilane coated stir bar for selective extraction of trace cadmium from environmental water samples followed by inductively coupled plasma mass spectrometry detection

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Nan [Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072 (China); Hu Bin, E-mail: binhu@whu.edu.cn [Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072 (China)

    2012-04-20

    deviation (RSD) was 3.38% (c = 1 {mu}g L{sup -1}, n = 7). The proposed method was successfully applied for the analysis of trace Cd(II) in rain water, East Lake and Yangtze River water. To validate the proposed method, certified reference material of GSBZ 50009-88 environmental water was analyzed and the determined value is in a good agreement with the certified value. The developed method is rapid, selective, sensitive and applicable for the analysis of trace Cd(II) in environmental water samples.

  5. Characterization of atmospheric trace elements in the Puruogangri ice core: a preliminary account of Tibetan Plateau environmental and contamination histories

    Science.gov (United States)

    Beaudon, E.; Gabrielli, P.; Sierra Hernandez, R.; Wegner, A.; Thompson, L. G.

    2014-12-01

    Asia is facing enormous challenges including large-scale environmental changes, rapid population growth and industrialization. The inherent generated pollution contributes to half of all Earth's anthropogenic trace metals emissions that, when deposited to glaciers of the surrounding mountains of the Third Pole region, leave a characteristic chemical fingerprint. Records of past atmospheric deposition preserved in snow and ice from Third Pole glaciers provide unique insights into changes of the chemical composition of the atmosphere and into the nature and intensity of the regional atmospheric circulation systems. The determination of the elemental composition of aeolian dust stored in Himalayan and Tibetan Plateau glaciers can help to qualify the potential contamination of glacial meltwater as a part of the greater fresh Asian water source. The 215 m long Puruogangri ice core retrieved in 2000 at 6500 m a.s.l. in central Tibetan Plateau (Western Tanggula Shan, China) provides one of the first multi-millennium-long environmental archives (spanning the last 7000 years and annually resolved for the last 400 years) obtained from the Tibetan Plateau region. The Puruogangri's area is climatologically of particular interest because of its location at the boundary between the monsoon (wet) and the westerly (dry) dominated atmospheric circulation. The major objective of this study is to determine the concentration of trace and ultra-trace elements in the Puruogangri ice core between 1600 and 2000 AD in order to characterize the atmospheric aerosols entrapped in the ice. Particular attention is given to assess the amount of trace elements originating from anthropogenic sources during both the pre-industrial and industrial periods. The distinction between the anthropogenic contribution and the crustal background may rely on the precise decoupling of the dry and wet seasons signals, the former being largely influenced by dust contribution.

  6. Determination of trace gold in rocks and minerals by neutron activation analysis

    International Nuclear Information System (INIS)

    Zhao Yunlong; Zhou Suqing; Liang Yutang

    1988-05-01

    The determination of trace gold in rocks and minerals by neutron activation analysis is described. Two methods are used for pre-separating and concentrating the trace gold in geological samples. one of the methods is that the samples are dissolved in aqua regia solution; activated carbon paper pulp filter is used for pre-separating and concentrating trace gold by dynamic adsorption method; then the activated carbon containing gold was ashed at 650 ∼ 700 deg c. The other method is that the samples are dissolved in aqua regia solution; the polyurethane foam plastic filled with activated carbon is used for pre-separating and concentrating trace gold by dynamic adsorption method; then the foam plastic containing gold was ashed at 650 deg c. The gold in ashes is determinated by neutron activation analysis. The detection limit is 0.004ng/g. The accuracy of the method is examined by gold in reference standard material. The results of this method are in good agreement with the recommended value. For analysis of the trace gold by the methods of instrumental neutron activation analysis and epithermal neutron activation analysis, the interference of 411.8 keV γ-ray from 153 Sm, 152 Eu and fission products of uranium and the correction methods are discussed

  7. Elemental analysis of biological materials. Current problems and techniques with special reference to trace elements

    International Nuclear Information System (INIS)

    1980-01-01

    Selected techniques were reviewed for the assay of trace and minor elements in biological materials. Other relevant information is also presented on the need for such analyses, sampling, sample preparation and analytical quality control. In order to evaluate and compare the applicability of the various analytical techniques on a meaningful and objective basis, the materials chosen for consideration were intended to be typical of a wide range of biological matrics of different elemental compositions, namely Bowen's kale, representing a plant material, and NBS bovine liver, IAEA animal muscle, and blood serum, representing animal tissues. The subject is reviewed under the following headings: on the need for trace element analyses in the life sciences (4 papers); sampling and sample preparation for trace element analysis (2 papers); analytical techniques for trace and minor elements in biological materials (7 papers); analytical quality control (2 papers)

  8. Trace element determination in beauty products by k0-instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Sneyers, L.; Verheyen, L.; Vermaercke, P.; Bruggeman, M.

    2009-01-01

    A recent study on trace elements in beauty products and cosmetics sold on the Asian market has shown the presence of high levels of U, Th and rare earth elements in so called 'Hormesis cosmetics'. For the purpose of comparison, some more information about trace elements in European cosmetics would be useful. In this paper the results obtained using k 0 -standardised Instrumental Neutron Activation Analysis (k 0 -INAA) for more than 20 trace elements in 20 different beauty products collected from the European market are presented. We found traces of Ba, As and Sb which is in breach with European legislation. For some of the other elements like Cr and Co further speciation is needed in order to evaluate their presence in beauty products. (author)

  9. A Geographic Information System (GIS) analysis for trace metal assessment of sediments in the Gulf of Paria, Trinidad

    International Nuclear Information System (INIS)

    Ragbirsingh, Y.; Norville, W.

    2005-01-01

    The Gulf of Paria is a semi-enclosed shallow basin with increasing coastal development activities along Trinidad's west coast. Sediments present a host for trace metal pollutants from overlying waters, therefore determination of their content is critical in evaluating and detecting sources of marine pollution. This paper presents a Geographic Information System (GIS) analysis of geochemical assessment for trace metals in coastal sediments of the Gulf of Paria. This GIS approach facilitates interpretation of the spatial relationships among key environmental processes. The GIS development involves the integration of spatial and attribute data pertaining to bathymetry, current systems, topography, rivers, land use/land cover and coastal sediments. It employs spatial interpolation and retrieval operations to analyze the total trace metal concentrations of aluminum, copper and lead in the sediments and the clay-enriched sediments, to determine whether they are related to sediment type or are affected by the discharge from anthropogenic sources. Spatial distribution modeling of element concentrations are produced to indicate contamination plumes from possible anthropogenic sources such as rivers entering the Gulf of Paria, and to reveal potential hot spots and dispersion patterns. A direct spatial correlation between clay-enriched sediments and high concentrations of aluminum and lead is detected, however regions of high concentrations of copper and lead indicate a relationship to anthropogenic sources. The effectiveness of GIS for visualization, spatial query and overlay of geochemical analysis is demonstrated [es

  10. Analysis of traces at ORNL's new high-flux neutron activation laboratory

    International Nuclear Information System (INIS)

    Ricci, E.; Handley, T.H.; Dyer, F.F.

    1974-01-01

    The investigations are outlined, which are carried out in order to develop (preferably instrumental) methods for multielement analysis of various trace elements. For this reason a new High-Flux NAA Laboratory was constructed at ORNL's. A general review is given on the Laboratory, further some methods and applications are shown. In the field of comparator activation analysis comparative data are given on mercury determinations in various matrices, and on arsenic determination in grasshoppers. This later method was used to trace the transport of arsenic containing pesticides. Some data are given on absolute activation analysis of Na, Ci, Mn, Br, and Au, too. (K.A.)

  11. Metals in environmental media: A study of trace and platinum group ...

    African Journals Online (AJOL)

    A detailed study has been conducted to determine the contamination of Thohoyandou roadside soils, vegetation, sewage and river waters by Zn, Cu, Cr, Pb, Cd, Fe, Pt and Pd. The study further investigated the correlation between these trace metals in roadside soils and vegetation in order to infer the potential impacts of ...

  12. Optical selection of trace elements for discriminant analysis

    International Nuclear Information System (INIS)

    Rasmussen, S.E.; Erasmus, C.S.; Watterson, J.I.W.; Sellschop, J.P.F.

    This report describes different methods of element selection; a combination of stepwise multivariate analysis of variance for primary element selection, and principle component analysis regression for the element interrelationship analysis. These offer a satisfactory solution to the problem of element selection

  13. Present status of neutron activation analysis in environmental research

    International Nuclear Information System (INIS)

    Steinnes, E.

    1984-01-01

    Neutron activation analysis, in spite of its many advantageous features, is less widely used than some alternative trace element techniques, and has been losing ground during the last decade. In the environmental field however there are still many problems which can be solved in a better way by the contribution of NAA. The combination of multi-element capability and high accuracy is of great importance in many studies related to atmospheric trace elements. Also in aquatic studies NAA still has a significant role to play. Applications to soils, sediments, and plant material have so far been limited, but there is a place for further development. The scope of NAA in environmental research may be extended by further use of pre-irradiation separations. NAA is particularly important in the certification of analytical reference materials in the environmental field. In future applications of NAA an appropriate combination with other analytical techniques will often be a requisite for success. The general future of NAA is dependent on the availability of nuclear reactors, radiochemical laboratoties and appropriate competence. 21 references

  14. Activation analysis of trace metals in several kinds of tissues of even-toed ungulates

    International Nuclear Information System (INIS)

    Fukushima, M.; Tamate, H.; Sato, S.; Terui, S.; Mitsugashira, T.

    1999-01-01

    The normal concentration levels of trace metals in several kinds of tissues of even-toed ungulates have been determined by instrumental neutron activation analysis, photon activation analysis, and flame atomic absorption spectrometry. In the present work the concentrations of 13 elements (Ag, Br, Ca, Co, Cu, Fe, Mg, Mn, Mo, Na, Rb, Se, and Zn) were analyzed. (author)

  15. TRACE ANALYSIS BY LASER-EXCITED ATOMIC FLUORESCENCE WITH ATOMIZATION IN A PULSED PLASMA

    OpenAIRE

    Lunyov , O.; Oshemkov , S.; Petrov , A.

    1991-01-01

    The possibilities of plasma atomization for laser fluorescence trace analysis are discussed. Pulsed hot hollow cathode discharge was used for analysis of solutions and powdered samples. The high voltage spark and laser-induced breakdown (laser spark) were used as atomizers of metal-containing atmospheric aerosols. Detection limits were improved by means of temporal background selection.

  16. Clean laboratories and clean rooms for analysis of radionuclides and trace elements

    International Nuclear Information System (INIS)

    2003-01-01

    requirements are summarized of clean laboratory environments, for construction materials as well as for materials used during routine analysis, maintenance, and pitfalls in the analysis of radionuclides and elements at trace- and ultra trace levels. Current methodologies and practices are described for planning the installation of a clean environment as well as protocols for maximizing the benefit-to-cost ratio and for achieving QA/QC. Special emphasis is given to the analysis of radionuclides, and measurement of trace, minor and major elements using nuclear and related analytical techniques such as NAA and XRF. Also included are papers contributed by experts from India, the Netherlands, the United States of America and the IAEA Laboratories, Seibersdorf

  17. Evaluations of the CCFL and critical flow models in TRACE for PWR LBLOCA analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jung-Hua; Lin, Hao Tzu [National Tsing Hua Univ., HsinChu, Taiwan (China). Dept. of Engineering and System Science; Wang, Jong-Rong [Atomic Energy Council, Taoyuan County, Taiwan (China). Inst. of Nuclear Energy Research; Shih, Chunkuan [National Tsing Hua Univ., HsinChu, Taiwan (China). Inst. of Nuclear Engineering and Science

    2012-12-15

    This study aims to develop the Maanshan Pressurized Water Reactor (PWR) analysis model by using the TRACE (TRAC/RELAP Advanced Computational Engine) code. By analyzing the Large Break Loss of Coolant Accident (LBLOCA) sequence, the results are compared with the Maanshan Final Safety Analysis Report (FSAR) data. The critical flow and Counter Current Flow Limitation (CCFL) play an important role in the overall performance of TRACE LBLOCA prediction. Therefore, the sensitivity study on the discharge coefficients of critical flow model and CCFL modeling among different regions are also discussed. The current conclusions show that modeling CCFL in downcomer has more significant impact on the peak cladding temperature than modeling CCFL in hot-legs does. No CCFL phenomena occurred in the pressurizer surge line. The best value for the multipliers of critical flow model would be 0.5 and the TRACE could consistently predict the break flow rate in the LBLOCA analysis as shown in FSAR. (orig.)

  18. Digital Stratigraphy: Contextual Analysis of File System Traces in Forensic Science.

    Science.gov (United States)

    Casey, Eoghan

    2017-12-28

    This work introduces novel methods for conducting forensic analysis of file allocation traces, collectively called digital stratigraphy. These in-depth forensic analysis methods can provide insight into the origin, composition, distribution, and time frame of strata within storage media. Using case examples and empirical studies, this paper illuminates the successes, challenges, and limitations of digital stratigraphy. This study also shows how understanding file allocation methods can provide insight into concealment activities and how real-world computer usage can complicate digital stratigraphy. Furthermore, this work explains how forensic analysts have misinterpreted traces of normal file system behavior as indications of concealment activities. This work raises awareness of the value of taking the overall context into account when analyzing file system traces. This work calls for further research in this area and for forensic tools to provide necessary information for such contextual analysis, such as highlighting mass deletion, mass copying, and potential backdating. © 2017 American Academy of Forensic Sciences.

  19. ICP-AES analysis of trace elements in serum from animals fed with irradiated food

    International Nuclear Information System (INIS)

    Huang Zongzhi; Zhou Hongdi

    1986-01-01

    A method of trace element analysis by ICP-AES in serum from animals fed with irradiated food is described. In order to demonstrate that irradiated food is suitable for human consumption, it is necessary to perform an experiment of animal feeding with these food before use for human. Trace element analysis in animal serum could provide an actual evidence for further human consumption study. 53 serum samples of the rats fed with irradiated food were obtained. After ashed and solved, ICP-AES analysis has been used for determining 20 trace elements in specimen solution. The detection limitation is in the range of 10 -2 -10 -3 ppm for different elements. The recovery of elements is from 70.08% to 98.28%. The relative standard deviation is found to be 0.71% to 11.52%

  20. A Trace-Driven Analysis of Wireless Group Communication Mechanisms

    Directory of Open Access Journals (Sweden)

    Surendar Chandra

    2012-08-01

    Full Text Available Wireless access is increasingly ubiquitous while mobile devices that use them are resource rich. These trends allow wireless users to collaborate with each other. We investigate various group communication paradigms that underly collaboration applications. We synthesize durations when members collaborate using wireless device availability traces. Wireless users operate from a variety of locations. Hence, we analyzed the behavior of wireless users in universities, corporations, conference venues, and city-wide hotspots. We show that the availability durations are longer in corporations followed by university and then in hotspots. The number of simultaneously available wireless users is small in all the scenarios. The session lengths are becoming smaller while the durations between sessions are becoming larger. We observed user churn in all the scenarios. We show that synchronous mechanisms require less effort to maintain update synchronicity among the group members. However, distributed mechanisms require a large number of replicas in order to propagate updates among the users. For asynchronous mechanisms, we show that pull-based mechanisms naturally randomize the times when updates are propagated and thus achieve better performance than push based mechanisms.We develop an adaptive approach that customizes the update frequency using the last session duration and show that this mechanism exhibits good performance when the required update frequency intervals are large. We also show that for a given number of gossips, it is preferable to propagate updates to all available nodes rather than increasing the frequency while correspondingly reducing the number of nodes to propagate updates.We develop a middleware to illustrate the practicality of our approach.

  1. Trace element profiles in modern horse molar enamel as tracers of seasonality: Evidence from micro-XRF, LA-ICP-MS and stable isotope analysis

    Science.gov (United States)

    de Winter, Niels; Goderis, Steven; van Malderen, Stijn; Vanhaecke, Frank; Claeys, Philippe

    2016-04-01

    A combination of laboratory micro-X-ray Fluorescence (μXRF) and stable carbon and oxygen isotope analysis shows that trace element profiles from modern horse molars reveal a seasonal pattern that co-varies with seasonality in the oxygen isotope records of enamel carbonate from the same teeth. A combination of six cheek teeth (premolars and molars) from the same individual yields a seasonal isotope and trace element record of approximately three years recorded during the growth of the molars. This record shows that reproducible measurements of various trace element ratios (e.g., Sr/Ca, Zn/Ca, Fe/Ca, K/Ca and S/Ca) lag the seasonal pattern in oxygen isotope records by 2-3 months. Laser Ablation-ICP-Mass Spectrometry (LA-ICP-MS) analysis on a cross-section of the first molar of the same individual is compared to the bench-top tube-excitation μXRF results to test the robustness of the measurements and to compare both methods. Furthermore, trace element (e.g. Sr, Zn, Mg & Ba) profiles perpendicular to the growth direction of the same tooth, as well as profiles parallel to the growth direction are measured with LA-ICP-MS and μXRF to study the internal distribution of trace element ratios in two dimensions. Results of this extensive complementary line-scanning procedure shows the robustness of state of the art laboratory micro-XRF scanning for the measurement of trace elements in bioapatite. The comparison highlights the advantages and disadvantages of both methods for trace element analysis and illustrates their complementarity. Results of internal variation within the teeth shed light on the origins of trace elements in mammal teeth and their potential use for paleo-environmental reconstruction.

  2. Activation analysis of several species of marine invertebrates as indicators of environmental conditions

    International Nuclear Information System (INIS)

    Fukushima, M.; Tamate, H.; Nakano, Y.

    2000-01-01

    Marine invertebrates are well known to accumulate trace metals from seawater, plankton, sea plants, and sediments. To test the usefulness of such organisms as a bio-indicator of environmental conditions, we have determined levels of trace elements in tissue of twelve species of marine invertebrates by photon and neutron activation analysis. Relatively higher concentration of elements were observed for Ni and Sn in mid-gut gland, for Cu and Zn in oyster tissues, for Se in swimming crabs, for Cu, Fe, and Se in gills of swimming crabs. Our results indicate that mid-gut gland of ear-shell will be useful as the indicator of environmental conditions. (author)

  3. Predicting Individual Characteristics from Digital Traces on Social Media: A Meta-Analysis.

    Science.gov (United States)

    Settanni, Michele; Azucar, Danny; Marengo, Davide

    2018-04-01

    The increasing utilization of social media provides a vast and new source of user-generated ecological data (digital traces), which can be automatically collected for research purposes. The availability of these data sets, combined with the convergence between social and computer sciences, has led researchers to develop automated methods to extract digital traces from social media and use them to predict individual psychological characteristics and behaviors. In this article, we reviewed the literature on this topic and conducted a series of meta-analyses to determine the strength of associations between digital traces and specific individual characteristics; personality, psychological well-being, and intelligence. Potential moderator effects were analyzed with respect to type of social media platform, type of digital traces examined, and study quality. Our findings indicate that digital traces from social media can be studied to assess and predict theoretically distant psychosocial characteristics with remarkable accuracy. Analysis of moderators indicated that the collection of specific types of information (i.e., user demographics), and the inclusion of different types of digital traces, could help improve the accuracy of predictions.

  4. Solid phase extraction for sample preparation in trace analysis of ionogenic compounds by capillary isotachophoresis

    International Nuclear Information System (INIS)

    Hutta, M.; Kaniansky, D.; Simunicova, E.; Zelenska, V.; Madajova, V.; Siskova, A.

    1992-01-01

    Various sorbents recommended for solid phase extraction (SPE) in sample preparation procedures were studied for use in combination with capillary isotachophoresis (ITP). They were very efficient in achieving trace concentration levels (low ppb, i.e., low parts per 10 9 ) for different types of ITP analytes present in environmental and biological matrices. A macroporous carbon sorbent was convenient for sample preparation in ITP analysis of short chain fatty acids (C 4 -C 9 ) in drinking water. Chelating sorbents based on hydroxyalkyl methacrylate matrix with salicylate, thioglycolate and 8-hydroxyquinolinate functionalities were found to be very suitable for preconcentration of heavy metals with an inherent sample clean-up. An octadecyl-bonded silica sorbent enabled in ITP a photometric detection of γ-aminobutyrate (labeled with a 2,4,6-trinitrophenyl group) at concentrations considerably lower than required for the determination of this amino acid in cerebrospinal fluid (∼5*10 -8 mol/l). (author) 34 refs.; 3 figs.; 1 tab

  5. Trace element analysis of soil type collected from the Manjung and central Perak

    Energy Technology Data Exchange (ETDEWEB)

    Azman, Muhammad Azfar, E-mail: m-azfar@nuclearmalaysia.gov.my; Hamzah, Suhaimi; Rahman, Shamsiah Abdul; Elias, Md Suhaimi; Abdullah, Nazaratul Ashifa; Hashim, Azian; Shukor, Shakirah Abd; Kamaruddin, Ahmad Hasnulhadi Che [Blok 18, Makmal Analisis Kimia (Aca/Bas), Agensi Nuklear Malaysia, 43000 Kajang, Selangor (Malaysia)

    2015-04-29

    Trace elements in soils primarily originated from their parent materials. Parents’ material is the underlying geological material that has been undergone different types of chemical weathering and leaching processes. Soil trace elements concentrations may be increases as a result of continuous input from various human activities, including power generation, agriculture, mining and manufacturing. This paper describes the Neutron Activation Analysis (NAA) method used for the determination of trace elements concentrations in part per million (ppm) present in the terrestrial environment soil in Perak. The data may indicate any contamination of trace elements contributed from human activities in the area. The enrichment factors were used to check if there any contamination due to the human activities (power plants, agricultural, mining, etc.) otherwise the values would serve as a baseline data for future study. The samples were collected from 27 locations of different soil series in the area at two different depths: the top soil (0-15cm) and the sub soil (15-30cm). The collected soil samples were air dried at 60°C and passed through 2 µm sieve. Instrumental Neutron Activation Analysis (NAA) has been used for the determination of trace elements. Samples were activated in the Nuclear Malaysia TRIGA Mark II reactor followed by gamma spectrometric analysis. By activating the stable elements in the samples, the elements can be determined from the intensities of gamma energies emitted by the respected radionuclides.

  6. Application of micro-PIXE analysis to investigate trace elements in deciduous teeth enamel

    International Nuclear Information System (INIS)

    Igari, K.; Takahashi, A.; Ando, H.

    2010-01-01

    The early life environment has widespread consequences for later health and disease. To prevent the disease in later life, the assessment of fetal environment is very important. In Japan, birthweight has fallen rapidly during recent two decades. The reduction of birthweight represents reduced fetal nutrition. Deciduous tooth enamel contains pre- and postnatal enamel and its chemical composition reflects the status of metabolism of trace elements during formation period. Deciduous tooth enamel is considered to be a suitable indicator of trace elements exposure in utero. We applied micro-PIXE analysis to investigate the trace elemental content in deciduous tooth enamel. Two deciduous canines from one healthy Japanese boy were used for this study. The enamel section including pre- and postnatal enamel was prepared for micro-PIXE analysis. Five trace elements (Na, Mg, Cl, Zn, and Sr) were detected in the scanning area of tooth. The distribution profiles of 5 elements were obtained as X-ray maps. The distribution profiles of zinc and chlorine were specific, and showed higher concentration in surface enamel. No elements showed different profiles of X-ray maps between pre- and postnatal enamel in this sample. The results of this study suggested that micro-PIXE analysis would be able to estimate the trace elements in prenatal and postnatal enamel, respectively. (author)

  7. Ar39 Detection at the 10-16 Isotopic Abundance Level with Atom Trap Trace Analysis

    Science.gov (United States)

    Jiang, W.; Williams, W.; Bailey, K.; Davis, A. M.; Hu, S.-M.; Lu, Z.-T.; O'Connor, T. P.; Purtschert, R.; Sturchio, N. C.; Sun, Y. R.; Mueller, P.

    2011-03-01

    Atom trap trace analysis, a laser-based atom counting method, has been applied to analyze atmospheric Ar39 (half-life=269yr), a cosmogenic isotope with an isotopic abundance of 8×10-16. In addition to the superior selectivity demonstrated in this work, the counting rate and efficiency of atom trap trace analysis have been improved by 2 orders of magnitude over prior results. The significant applications of this new analytical capability lie in radioisotope dating of ice and water samples and in the development of dark matter detectors.

  8. Trace elements evaluation of some medicinal herbs by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Zaidi, J.H.; Fatima, I.; Qureshi, I.H.; Subhani, M.S.

    2004-01-01

    Instrumental neutron activation analysis has been used for the analysis of seven varieties of medicinal herbs generally used by the people of South Asian region. Twenty-one trace elements (essential, toxic and non-essential) were determined. This data should not only be helpful in establishing the base-line values in these medicinal herbs but also in correlating their role as therapeutic agents. A comparison of our data with literature values shows variation in trace element contents of same species of different origin which can be attributed to ecological and geographical variations to some extent; however an exact interpretation demands further extensive investigations. (orig.)

  9. Biomonitoring of air pollution through trace element analysis

    International Nuclear Information System (INIS)

    Bamford, S.A.; Osae, E.K.; Aboh, I.J.; Serfor-Armah, Y.; Nyarko, B.; Odamtten, G.T.

    1999-01-01

    Studies are being carried out to determine the potential and reliability in the use of local lichen species for biomonitoring air pollution in Ghana. The location of most of the gold mines in forest areas of the country presents the gold mining industry as a suitable setting for such investigations. The nuclear-related techniques being used in the multielement analysis of lichen samples and air filter samples are instrumental neutron activation analysis (Miniature Neutron Source Reactor) and energy dispersive x-ray fluorescence analysis (tube-excitation). Validation of the quantitative methods of the INAA through analysis of standard and certified reference materials of orchard leaves NBS SRM 1571 and BCR-CRM No. 279 gave very good results for most elements analyzed. Elemental analysis of identified lichen samples will be done beating in mind microclimatic factors, specie type and nature of soil. (author)

  10. Biomonitoring of air pollution through trace element analysis

    International Nuclear Information System (INIS)

    Bamford, S.A.; Osae, E.K.; Aboh, I. J.; Serfor-Armah, Y.; Nyarko, B.; Ofosu, F.; Odamtten, G.T.

    1999-04-01

    Studies are being carried out to determine the potential and reliability in the use of local lichen species for biomonitoring air pollution in Ghana. The location of most of the gold mines in forest areas of the country presents the gold mining industry as a suitable setting for such investigations. The nuclear-related techniques being used in the multielement analysis of lichen samples and air filter samples are instrumental neutron activation analysis (Miniature Neutron Source Reactor) and energy dispersive x-ray fluorescence analysis (tube-excitation). Validation of the quantitative methods of the INAA through analysis of standard certified reference materials of orchard leaves NBS SRM 1571 and BCR-CRM No. 279 gave very good results for most elements analyzed. Elemental analysis of identified lichen samples will be done bearing in mind microclimatic factors, specie type and nature of soil. (author)

  11. All-Optical Atom Trap Trace Analysis: Potential Use of 85Kr in Safeguards Activities

    International Nuclear Information System (INIS)

    Kohler, M.; Sahling, P.; Sieveke, C.; Kirchner, G.

    2015-01-01

    Sensitive measurement techniques for the detection of anthropogenic tracers demand measurement resolutions down to single atoms, as it has been demonstrated by the first atom trap trace analysis experiments. However, technical limitations had lowered the sample throughput to about 200 per year per machine. We have developed an all-optical apparatus which allows higher sample throughput and small sample sizes at the same time. Krypton-85 as anthropogenic isotope is an ideal tracer for nuclear activities since the only relevant source term is fission. An increased 85Kr concentration in an air sample indicates, that a plume was passing by during sampling. In practice, however, its applicability may be limited by the global and regional background concentrations caused by the emissions of nuclear fuel reprocessing plants. The potential of 85Kr monitoring for safeguards applications has been discussed extensively. Among these is the short range detection of elevated concentrations of 85Kr in the vicinity of reprocessing plants. Our ATTA technique needs sample sizes of about 1 l of air only and thus for the first time will allow simple environmental sampling of 85Kr with high spatial and temporal resolution. The design of such a study including local sampling and tracer transport modelling in proximity to a reprocessing plants is outlined. In addition, such a study could be used also for validating near-field atmospheric dispersion models if the 85Kr source term is known. The potential of environmental analyzes of 85Kr during an IAEA short-notice access is discussed. It is shown that it crucially depends on the emission dynamics after shut-down of fuel dissolution which needs further study. (author)

  12. The ultimate response guideline simulation and analysis by using (TRACE) for Lungmen ABWR nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Hao-Tzu [Atomic Energy Council, Inst. of Nuclear Energy Research, Taoyuan City, Taiwan (China); Yang, Shu-Ming; Chen, Shao-Wen; Wang, Jong-Rong; Shih, Chunkuan [National Tsing Hua Univ., Inst. of Nuclear Engineering and Science, HsinChu, Taiwan (China)

    2015-07-15

    In this research, the TRACE/SNAP model of Lungmen ABWR nuclear power plant (NPP) has been established for the simulation and analysis of ultimate response guideline (URG). The main actions of URG are depressurization and low pressure water injection of reactor and containment venting. This research focuses to assess the URG utility of Lungmen NPP under Fukushima-like conditions. This study consists of three steps. The first step is the establishment of Lungmen NPP TRACE/SNAP model. In order to evaluate the system response of TRACE/SNAP model, FSAR data (MSIV closure and loss of feedwater flow transient) were used to compare with the results of TRACE. The second step is the URG simulation and analysis under Fukushima-like conditions by using Lungmen NPP TRACE/SNAP model. In this step, the no URG case was also performed in order to evaluate the URG effectiveness of Lungmen NPP. In order to confirm the mechanical property and integrity of fuel rods, the final step is FRAPTRAN analysis. According to TRACE analysis results, the URG can keep the peak cladding temperature (PCT) below the criteria 1088.7 K under Fukushima-like conditions which indicates that Lungmen NPP can be controlled in a safe situation. Nevertheless, if Lungmen NPP does not perform the URG under Fukushima-like conditions, the water level may drop lower than TAF after 1100 s which means a safety issue about the fuel rods may be generated. The analysis results of FRAPTRAN also indicate the integrity of fuel rods cannot be kept under the above conditions.

  13. From consumption to harvest: Environmental fate prediction of excreted ionizable trace organic chemicals

    DEFF Research Database (Denmark)

    Polesel, Fabio; Plósz, Benedek G.; Trapp, Stefan

    2015-01-01

    Excreted trace organic chemicals, e.g., pharmaceuticals and biocides, typically undergo incomplete elimination in municipal wastewater treatment plants (WWTPs) and are released to surface water via treated effluents and to agricultural soils through sludge amendment and/or irrigation with freshwa......Excreted trace organic chemicals, e.g., pharmaceuticals and biocides, typically undergo incomplete elimination in municipal wastewater treatment plants (WWTPs) and are released to surface water via treated effluents and to agricultural soils through sludge amendment and/or irrigation...... with freshwater or reclaimed wastewater. Recent research has shown the tendency for these substances to accumulate in food crops. In this study, we developed and applied a simulation tool to predict the fate of three ionizable trace chemicals (triclosan-TCS, furosemide-FUR, ciprofloxacin-CIP) from human...... and a recently developed dynamic soil-plant uptake model. The simulation tool was tested using country-specific (e.g., consumption/emission rates, precipitation and temperature) input data. A Monte Carlo-based approach was adopted to account for the uncertainty associated to physico-chemical and biokinetic model...

  14. Environmental analysis in small and medium enterprises

    International Nuclear Information System (INIS)

    Luciani, R.; Andriola, L.; Di Franco, N.

    2001-01-01

    An environmental analysis is considered to be one of the primary goals for an enterprise environmental management. Nevertheless the complexity of the environmental problems and of its regulations prevents the small enterprises the possibility to perform an environmental policy (EMAS, ISO 14001). One of the most correct evaluation instrument for creating a datum-point standard could be the filling up a questionnaire, built up in according to the industrial enterprises need. It has the function of creating a primary step for a subsequent environmental management [it

  15. Illustration and analysis of a coordinated approach to an effective forensic trace evidence capability.

    Science.gov (United States)

    Stoney, David A; Stoney, Paul L

    2015-08-01

    An effective trace evidence capability is defined as one that exploits all useful particle types, chooses appropriate technologies to do so, and directly integrates the findings with case-specific problems. Limitations of current approaches inhibit the attainment of an effective capability and it has been strongly argued that a new approach to trace evidence analysis is essential. A hypothetical case example is presented to illustrate and analyze how forensic particle analysis can be used as a powerful practical tool in forensic investigations. The specifics in this example, including the casework investigation, laboratory analyses, and close professional interactions, provide focal points for subsequent analysis of how this outcome can be achieved. This leads to the specification of five key elements that are deemed necessary and sufficient for effective forensic particle analysis: (1) a dynamic forensic analytical approach, (2) concise and efficient protocols addressing particle combinations, (3) multidisciplinary capabilities of analysis and interpretation, (4) readily accessible external specialist resources, and (5) information integration and communication. A coordinating role, absent in current approaches to trace evidence analysis, is essential to achieving these elements. However, the level of expertise required for the coordinating role is readily attainable. Some additional laboratory protocols are also essential. However, none of these has greater staffing requirements than those routinely met by existing forensic trace evidence practitioners. The major challenges that remain are organizational acceptance, planning and implementation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Study on trace element determination in liver samples of great-white-egret Ardea alba Linnaeus, 1758 (Ardeidae, Aves) for environmental contamination biomionitoring

    International Nuclear Information System (INIS)

    Silva, Rita de Cassia A.; Saiki, Mitiko

    2009-01-01

    Predatory birds such as herons have been used as bioindicators of pollution since they are at the top of their food webs. The tissues of these animals are analyzed for assessing environmental pollution caused by toxic elements. In the present study, adequate experimental conditions were established for determination of trace elements concentrations in the liver samples of Great-white-egret (Ardea alba Linnaeus, 1758) for further application of this specimens as a bioindicator of environmental contamination. Four liver samples were collected from Greatwhite- egrets found in the metropolitan region of Sao Paulo and were they analyzed by the method of neutron activation analysis (NAA). Concentrations of the elements Br, Co, Cs, Fe, Na, Rb, Se and Zn were measured in these liver tissues. The findings of this present study demonstrated that the established procedure for liver sample treatment was appropriate to obtain a homogeneous sample. The method of neutron activation analysis (NAA) was very promising for liver sample analysis for evaluation of environmental contamination. (author)

  17. Study on trace element determination in liver samples of great-white-egret Ardea alba Linnaeus, 1758 (Ardeidae, Aves) for environmental contamination biomionitoring

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rita de Cassia A.; Saiki, Mitiko, E-mail: rcsilva@ipen.b, E-mail: mitiko@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    Predatory birds such as herons have been used as bioindicators of pollution since they are at the top of their food webs. The tissues of these animals are analyzed for assessing environmental pollution caused by toxic elements. In the present study, adequate experimental conditions were established for determination of trace elements concentrations in the liver samples of Great-white-egret (Ardea alba Linnaeus, 1758) for further application of this specimens as a bioindicator of environmental contamination. Four liver samples were collected from Greatwhite- egrets found in the metropolitan region of Sao Paulo and were they analyzed by the method of neutron activation analysis (NAA). Concentrations of the elements Br, Co, Cs, Fe, Na, Rb, Se and Zn were measured in these liver tissues. The findings of this present study demonstrated that the established procedure for liver sample treatment was appropriate to obtain a homogeneous sample. The method of neutron activation analysis (NAA) was very promising for liver sample analysis for evaluation of environmental contamination. (author)

  18. Correlation analysis of trace elemental data obtained from blood sera of ovarian cancer patients using PIXE

    International Nuclear Information System (INIS)

    Naidu, B.G.; Sarita, P.; Naga Raju, G.J.

    2017-01-01

    Proton induced X-ray emission (PIXE) technique is used for analysis of trace elements present in the blood sera of ovarian cancer patients and healthy controls. This work is also intended to establish the role played by trace elements in carcinogenic process. It is observed that the concentrations of elements Ti, V, Cr, Mn, Fe, Ni, Rb and Sr are lower and the concentration of Cu is higher in the cancer patients when compared to controls. However, no change in concentration is found in the elements Co, Zn, As, Se and Br. Correlation analysis of the data using SPSS 16.0 has revealed a strong positive correlation between Ti-V, Ni-Co, Cu-Fe, As-Ti, Br-Ti, Br-V and Sr-Fe while strong negative correlations are observed for Cu-Ti, As-Cu and Br-Cu. Changes in trace elemental content are probably associated with ovarian carcinogenesis. (author)

  19. Determination of trace elements in cigarette and tobacco by neutron activation analysis

    International Nuclear Information System (INIS)

    Nouchpramool, S.

    1988-01-01

    The objective of this work is to determine the concentration of 22 trace elements in cigarette and tobacco by instrumental neutron activation analysis in which multielements can be analyzed simultaneously with high sensitivity and reliability as well as easy and rapid. It is well known that, trace toxic elements with high concentration may be harmful for health of smokers. Since they might damage the respiratory system and might cause other diseases. The finding for this report can be used as the basis of further study on toxic of trace elements to the smoker. The results of this analysis show that the bromine content in all samples is significantly high, but the concentration of the other elements are varying from one to another. Bromine concentration might come from soil and/or smoked tobacco leaves with methyl bromide as fungicide

  20. Biomonitoring of air pollution in Jamaica through trace-element analysis of epiphytic plants using nuclear and related analytical techniques

    International Nuclear Information System (INIS)

    Vutchkov, Mitko

    2001-01-01

    The main goal of the Coordinated Research Project (No:9937/R0), entitled 'Biomonitoring of Air Pollution in Jamaica Through Trace-Element Analysis of Epiphytic Plants Using Nuclear and Related Analytical Techniques', is to identify and validate site specific epiphytic plants for biomonitoring the atmospheric pollution in Jamaica using nuclear analytical techniques at the International Centre for Environmental and Nuclear Sciences (ICENS). The specific objectives for the second year of the project were: Development of HOP for sampling epiphytic plants in Jamaica; Sampling design and sample collection; Sample preparation and analysis; Development of an in-house SRM and participation in the NAT-5 inter-laboratory study; Data analysis and interpretation of the results; Development of a work plan of the third year of the project

  1. Magnetic sulfur-doped porous carbon for preconcentration of trace mercury in environmental water prior to ICP-MS detection.

    Science.gov (United States)

    Peng, Chuyu; He, Man; Chen, Beibei; Huang, Lijin; Hu, Bin

    2017-11-20

    A novel magnetic sulfur-doped porous carbon (MSPC) was fabricated via a simple one-step carbonization of a mixture of sucrose, basic magnesium sulfate whiskers and Fe 3 O 4 @SiO 2 nanoparticles. Due to the high S content, the prepared MSPC possessed high adsorption capacity for Hg 2+ (343 mg g -1 ) with good selectivity. Based on this, a method coupling magnetic solid phase extraction (MSPE) with inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of trace Hg 2+ in environmental water samples. Various parameters such as pH, desorption solvent and its concentration, desorption volume and time, sample volume, and adsorption time that affect the determination have been optimized. Under the optimal conditions, a high enrichment factor of 100-fold was obtained, the limit of detection (LOD) was found to be 0.52 pg mL -1 with a relative standard deviation (c = 10 pg mL -1 , n = 7) of 7.1%, and a good linearity was obtained within the concentration range of 2-5000 pg mL -1 for Hg 2+ . Besides, the proposed method has very fast adsorption/desorption kinetics, target Hg 2+ could be rapidly adsorbed on the prepared MSPC in 2 min and desorbed from the MSPC in 2 min with the assistance of a permanent magnet. Therefore, the proposed method of MSPE-ICP-MS exhibits good application potential in the determination of trace Hg 2+ in environmental water samples.

  2. Mass spectrometric methods for trace analysis of metals

    International Nuclear Information System (INIS)

    Bahr, U.; Schulten, H.R.

    1981-01-01

    A brief outline is given of the principles of mass spectrometry (MS) and the fundamentals of qualitative and quantitative mass spectrometric analysis emphasizing recent developments and results. Classical methods of the analysis of solids, i.e. spark-source MS and thermal ionization MS, as well as recent methods of metal analysis are described. Focal points in this survey of recently developed techniques include secondary ion MS, laser probe MS, plasma ion source MS, gas discharge MS and field desorption MS. Here, a more detailed description is given and the merits of these emerging methods are discussed more explicitly. In particular, the results of the field desorption techniques in elemental analyses are reviewed and critically evaluated

  3. Nuclear analysis techniques and environmental sciences

    International Nuclear Information System (INIS)

    1997-10-01

    31 theses are collected in this book. It introduced molecular activation analysis micro-PIXE and micro-probe analysis, x-ray fluorescence analysis and accelerator mass spectrometry. The applications about these nuclear analysis techniques are presented and reviewed for environmental sciences

  4. Formal analysis of empirical traces in incident management

    International Nuclear Information System (INIS)

    Hoogendoorn, Mark; Jonker, Catholijn M.; Maanen, Peter-Paul van; Sharpanskykh, Alexei

    2008-01-01

    Within the field of incident management split second decisions have to be made, usually on the basis of incomplete and partially incorrect information. As a result of these conditions, errors occur in such decision processes. In order to avoid repetition of such errors, historic cases, disaster plans, and training logs need to be thoroughly analysed. This paper presents a formal approach for such an analysis that pays special attention to spatial and temporal aspects, to information exchange, and to organisational structure. The formal nature of the approach enables automation of analysis, which is illustrated by case studies of two disasters

  5. Improved PIXE analysis of micro- and trace elements in dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Ciortea, C.; Fluerasu, D.; Enescu, S. E.; Preoteasa, E.

    2001-01-01

    Due to the interactions occurring at the solid-solid and solid-liquid interfaces of a tooth's filling, the mineral elements of the restorative composite may induce a complex response of the organism. To study such problems, sensitive surface trace element analysis is required. Particle-induced X-ray emission (PIXE) has a detection limit one order of magnitude lower than XRF and has been used for hard dental tissues, but not yet for dental composites. We evaluated the potential of PIXE in a study of ten types of composites used in restorative dentistry, some of them with two color shades each. The samples were prepared as described for XRF. The measurements were performed with 3 MeV protons from a van de Graaff tandem linear accelerator, using a hyper pure Ge detector and collecting the spectra for 1.5-4 hours. The spectra were processed with the program Leone. The proton route in the sample calculated with the Trim program (∼ 50-100 μm) exceeded the size of mineral particles (0.02-30 μm), thus granularity did not affect the analysis. The PIXE analysis detected Z ≥ 19 elements in all composites, and Z≥14 elements in only one low Z material. PIXE detected generally the same dominant elements, but many more trace elements than XRF. Thus both Charisma (Kulzer) and Pekafill (Bayer) contained Ba as the major element, but trace elements were Ni, Zn, In, in the first, and Fe, Cu, Zn, Sr, Ag in the second. In other glass- and ceramics-based materials we found: Ca, Zr, Ba, Yb and traces of Sr, In, and possibly Ti in Tetric Ceram and in Ariston (both from Vivadent); Ca, Zr, Ba, Hf, possibly Mn, and traces of Ni, Ho, Ti, Fe, Cr in Valux Plus (3M Dental); Sr, Ba (major), K, Fe, Mn (minor), and traces of Ni, Zn, In, in F2000 Compomer (3M Dental); Ba (major) and traces of Fe, Ni, Sr in Surefil (Dentsply). In quartz-based materials we detected: Si, Ca, Ti, Fe and traces of K, Cl, Cr, Ni, Cu, Zn in Evicrol (Spofa); low and trace levels of Ca, Ti, Cr, Mn, Fe, Cu in

  6. Trace element analysis of archaeological artefacts from Pella, Jordan

    International Nuclear Information System (INIS)

    Clayton, E.

    1985-01-01

    A brief history of the site at Pella, Jordan is presented, as a prelude to an analysis of the element composition of 82 pottery sherds. Statistical results from this data support the archaeological evidence for occupation during the Late Bronze and Early Iron Age

  7. Trace element analysis at the Livermore pool-type reactor using neutron activation techniques

    International Nuclear Information System (INIS)

    Ragaini, R.C.; Ralston, R.; Garvis, D.

    1975-01-01

    The capabilities of trace element analysis at the Livermore Pool-Type Reactor (LPTR) using instrumental neutron activation analysis (INAA) are discussed. A description is given of the technology and the methods employed, including sample preparation, irradiation, and analysis. Applications of the INAA technique in past and current projects are described. A computer program, GAMANAL, has been used for nuclide identification and quantification. (U.S.)

  8. Environmental exposure of Atlantic horseshoe crab (Limulus polyphemus) early life stages to essential trace elements.

    Science.gov (United States)

    Bakker, Aaron K; Dutton, Jessica; Sclafani, Matthew; Santangelo, Nicholas

    2016-12-01

    This study investigated the accumulation Co, Cu, Fe, Mn, Ni, Se, and Zn in Atlantic horseshoe crab (Limulus polyphemus) early life stages (egg, embryo and larvae) and compared the concentrations to the concentration of each element in sediment, pore water and overlying water for 5 sites across Long Island, NY. For the majority of the sites, all essential trace elements accumulated in the embryos and larvae. However, many of the embryos and larvae at specific sites presented different concentration patterns which had no apparent relationship with the local habitat sediment and water values. Generally, Cu, Fe, and Se sequentially increased from egg stage through larval stages for the majority of sites, while Co, Mn, and Ni only did for a few sites. Zinc also showed an increase across sites from embryo to larval stage, however was the only one to show a decrease in concentration from egg to embryo stage at all sites. Interestingly, Mn at Manhasset Bay presented embryo and larval stages to be 50 fold greater than all other sites while the egg stage showed similar values to other sites; this high degree of uptake could be due to a high concentration in the overlying water. All essential trace elements can be accumulated from the environment but greater concentrations may be influenced by abiotic factors and the predominant uptake route (aqueous versus diet) at each life stage. Future laboratory experiments are required to investigate factors that influence essential trace element accumulation and loss in horseshoe crab early life stages. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Biomonitoring of air pollution through trace element analysis

    International Nuclear Information System (INIS)

    Akoto Bamford, Samuel; Osae, E.K.; Serfor-Armah, Y.; Nyarko, B.; Ofosu, F.; Aboh, I.J.; Odamtten, G.T.

    2001-01-01

    Research work is currently going on to determine the suitability in the use of local lichen species for biomonitoring air pollution in Ghana. The study areas being investigated are the gold-mining areas situated in the Moist Evergreen and Semi-Deciduous forests in Ghana. The nuclear analytical techniques being used in this work are instrumental neutron activation analysis and tube-excited x-ray fluorescence spectrometry. The present report covers results of quality control exercise carried out to validate the quantitative methods being used. This includes our participation in an intercomparison exercise carried out among participants of the IAEA coordinated research project. The samples analyzed were two lichen samples from two completely different areas using neutron activation analysis. Only short- and medium-lived irradiations were carried out. Satisfactory results were obtained for most of the elements identified and quantified. (author)

  10. Trace elemental analysis of bituminous coals using the Heidelberg proton microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Chen, J R; Kneis, H; Martin, B; Nobiling, R; Traxel, K [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany, F.R.); Heidelberg Univ. (Germany, F.R.). Physikalisches Inst.); Chao, E C.T.; Minkin, J A [Geological Survey, Reston, VA (USA)

    1981-03-01

    Trace elements in coal can occur as components of either the organic constituents (macerals) or the inorganic constituents (minerals). Studies of the concentrations and distribution of the trace elements are vital to understanding the geochemical milieu in which the coal was formed and in evaluating the attempts to recover rare but technologically valuable metals. In addition, information on the trace element concentrations is important in predicting the environmental impact of burning particular coals, as many countries move toward greater utilization of coal reserves for energy production. Traditionally, the optical and the electron microscopes and more recently the electron microprobe have been used in studying the components of coal. The proton-induced X-ray emission (PIXE) microprobe offers a new complementary approach with an order of magnitude or more better minimum detection limit. We present the first measurements with a PIXE microprobe of the trace element concentrations of bituminous coal samples. Elemental analyses of the coal macerals-vitrinite, exinite, and inertinite - are discussed for three coal samples from the Eastern U.S.A., three samples from the Western U.S.A., and one sample from the Peoples Republic of China.

  11. Trace analysis in the food and beverage industry by capillary gas chromatography: system performance and maintenance.

    Science.gov (United States)

    Hayes, M A

    1988-04-01

    Gas chromatography (GC) is the most widely used analytical technique in the food and beverage industry. This paper addresses the problems of sample preparation and system maintenance to ensure the most sensitive, durable, and efficient results for trace analysis by GC in this industry.

  12. Archaeological significance of trace element analysis of South West African potsherds

    International Nuclear Information System (INIS)

    Boule, G.J.; Peisach, M.; Jacobson, L.

    1979-01-01

    The archaeological study of early population movements in South West Africa/Namibia has been aided by trace element analysis of potsherds. The results suggest that the central areas of the country were populated by mobile groups of pastoralists and hunter-gatherers, while the northern areas were settled by sedentary peoples [af

  13. Potential interferences inherent in neutron-activation analysis of trace elements in biological materials

    International Nuclear Information System (INIS)

    Cornells, R.; Hoste, J.; Versieck, J.

    1982-01-01

    A comprehensive review is given of how neutron-activation analysis for trace elements in biological matrices can be jeopardized by radiation damage, by the impurities present in the packing material or by nuclear interferences of major elements. Systematic errors during the counting process and the quantitative interpretation of the γ-ray spectra should not be disregarded. (author)

  14. Pixe analysis of trace elements in tissues of rats treated with anticonvulsants

    Science.gov (United States)

    Hurd, R. W.; Van Rinsvelt, H. A.; Kinyua, A. M.; O'Neill, M. P.; Wilder, B. J.; Houdayer, A.; Hinrichsen, P. F.

    1987-04-01

    Several lines of evidence implicate metals in epilepsy. Anticonvulsant drugs are noted to alter levels of metals in humans and animals. PIXE analysis was used to investigate effects of three anticonvulsant drugs on tissue and brain cortex trace elements. The content of zinc and copper was increased in liver and spleen of rats treated with anticonvulsants while selenium was decreased in cortex.

  15. PIXE analysis of trace elements in tissues of rats treated with anticonvulsants

    Energy Technology Data Exchange (ETDEWEB)

    Hurd, R.W.; Van Rinsvelt, H.A.; Kinyua, A.M.; O' Neill, M.P.; Wilder, B.J.; Houdayer, A.; Hinrichsen, P.F.

    1987-04-01

    Several lines of evidence implicate metals in epilepsy. Anticonvulsant drugs are noted to alter levels of metals in humans and animals. PIXE analysis was used to investigate effects of three anticonvulsant drugs on tissue and brain cortex trace elements. The content of zinc and copper was increased in liver and spleen of rats treated with anticonvulsants while selenium was decreased in cortex.

  16. PIXE analysis of trace elements in tissues of rats treated with anticonvulsants

    International Nuclear Information System (INIS)

    Hurd, R.W.; Van Rinsvelt, H.A.; Kinyua, A.M.; O'Neill, M.P.; Wilder, B.J.; Florida Univ., Gainesville; Houdayer, A.; Hinrichsen, P.F.

    1987-01-01

    Several lines of evidence implicate metals in epilepsy. Anticonvulsant drugs are noted to alter levels of metals in humans and animals. PIXE analysis was used to investigate effects of three anticonvulsant drugs on tissue and brain cortex trace elements. The content of zinc and copper was increased in liver and spleen of rats treated with anticonvulsants while selenium was decreased in cortex. (orig.)

  17. Trace elements in Turkish tobacco determined by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Guelovali, M.C.; Guenduez, G.

    1983-01-01

    The concentration of 20 trace elements in nine brands of Turkish cigarette tobacco and in a brand of pipe tobacco ash has been determined by instrumental neutron activation analysis. The percent transference of elements into smoke has been estimated from the amounts remaining in the ash. (author)

  18. Application of neutron activation analysis to trace elements determinations in lung samples

    International Nuclear Information System (INIS)

    Rogero, S.O.

    1991-01-01

    The purpose of this work was to apply the instrumental neutron activation analysis method to determine trace elements in lung samples from smokers and non smokers. Samples of lung tissues and lymph nodes from pulmonary hilum analyzed were collected from autopsies by researchers from Faculdade de Medicina da USP. (author)

  19. Analysis of multiple single nucleotide polymorphisms (SNP) on DNA traces from plasma and dried blood samples

    NARCIS (Netherlands)

    Catsburg, Arnold; van der Zwet, Wil C.; Morre, Servaas A.; Ouburg, Sander; Vandenbroucke-Grauls, Christina M. J. E.; Savelkoul, Paul H. M.

    2007-01-01

    Reliable analysis of single nucleotide polymorphisms (SNPs) in DNA derived from samples containing low numbers of cells or from suboptimal sources can be difficult. A new procedure to characterize multiple SNPs in traces of DNA from plasma and old dried blood samples was developed. Six SNPs in the

  20. Trace element concentrations in human bone using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    El-Amri, F.A.; El-Kabroun, M.A.R.

    1997-01-01

    Instrumental neutron activation analysis has been applied to analyze 23 bone samples obtained from Libyan patient aged (3-80) years for the study of the concentration levels of trace elements Ba, Br, Ca, Fe, Sr and Zn and their concentration patterns regarding to the age and sex of the patients. (author)

  1. Trace elements monitored with neutron activation analysis durig neurodegeneration in brains of mutant mice

    Czech Academy of Sciences Publication Activity Database

    Kranda, Karel; Kučera, Jan; Bäurle, J.

    2006-01-01

    Roč. 269, č. 3 (2006), s. 555-559 ISSN 0236-5731 Institutional research plan: CEZ:AV0Z10480505 Keywords : trace elements * neutron activation analysis * brain neurodegeneration * mutant mice Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.509, year: 2006

  2. Characterization of elements in trace amounts in imperial topaz through neutron activation analysis

    International Nuclear Information System (INIS)

    Oliveira, Ester Figueiredo de; Sabioni, Antonio C. S.; Ferreira, Cesar M.

    2000-01-01

    This work deals with the mineral characterization of the elements in trace amounts of imperial topaz, original form Mina Capao da Lama, Ouro Preto, MG, Brazil, through the neutron activation analysis. Recent results have permitted to quantify Cr, Cs, Mn, Na, Ga, Sb and Au. The main goal of this study is the contribution to the mineral and gemological research of the imperial topaz

  3. Determination of trace elements in biological material by neutron activation analysis

    International Nuclear Information System (INIS)

    Tran Van, L.; Teherani, D.K.

    1989-01-01

    Eighteen trace elements in biological materials [grass (Imperata cylindrica), mimosa plant (Mimosa pudica), rice] by neutron activation method were determined. In the comparative analysis the content of the same element was different in each material, although they were collected at the same place and the same sampling method was applied. (author) 4 refs.; 1 fig.; 1 tab

  4. Radiotracer investigation of the cold-vapour atomic absorption method of analysis for trace mercury

    International Nuclear Information System (INIS)

    Stuart, D.C.

    1978-01-01

    Because of certain problems found in application of the atomic absorption method for trace analysis of mercury, a careful check of the procedures used was undertaken, with radiotracer mercury to facilitate the investigation. The results obtained, in conjunction with those of sample ashing procedures, indicate that the method is less straightforward than its simplicity suggests. (Auth.)

  5. Environmental Management Strategy: Four Forces Analysis

    Science.gov (United States)

    Doyle, Martin W.; Von Windheim, Jesko

    2015-01-01

    We develop an analytical approach for more systematically analyzing environmental management problems in order to develop strategic plans. This approach can be deployed by agencies, non-profit organizations, corporations, or other organizations and institutions tasked with improving environmental quality. The analysis relies on assessing the underlying natural processes followed by articulation of the relevant societal forces causing environmental change: (1) science and technology, (2) governance, (3) markets and the economy, and (4) public behavior. The four forces analysis is then used to strategize which types of actions might be most effective at influencing environmental quality. Such strategy has been under-used and under-valued in environmental management outside of the corporate sector, and we suggest that this four forces analysis is a useful analytic to begin developing such strategy.

  6. Environmental management strategy: four forces analysis.

    Science.gov (United States)

    Doyle, Martin W; Von Windheim, Jesko

    2015-01-01

    We develop an analytical approach for more systematically analyzing environmental management problems in order to develop strategic plans. This approach can be deployed by agencies, non-profit organizations, corporations, or other organizations and institutions tasked with improving environmental quality. The analysis relies on assessing the underlying natural processes followed by articulation of the relevant societal forces causing environmental change: (1) science and technology, (2) governance, (3) markets and the economy, and (4) public behavior. The four forces analysis is then used to strategize which types of actions might be most effective at influencing environmental quality. Such strategy has been under-used and under-valued in environmental management outside of the corporate sector, and we suggest that this four forces analysis is a useful analytic to begin developing such strategy.

  7. Principle of neutron activation analysis and its use for determination of trace elements in sediment

    International Nuclear Information System (INIS)

    Verma, Rakesh

    2012-01-01

    Neutron Activation analysis (NAA) is a multi element analysis technique, often non-destructive in nature where approximately 75 elements can be measured with the detection limits ranging from 10 -6 to 10 -12 g of element in a sample. Typical sample sizes range from 1 mg to 1 g, however in principle much larger samples can be activated and the size is only limited by the capacity of the neutron irradiation facility. In NAA, a sample (solid or liquid or gas) is exposed to neutrons and radiations emitted by the radioactive products, formed during the nuclear reaction, are measured using a suitable detector. The energy of the emitted radiation is a characteristic of a radioisotope whereas the intensity of the emitted radiation is proportional to the mass of the analyte. NAA can be carried out by measurement of (i) prompt gamma rays emitted by compound nucleus, called prompt gamma ray NAA (PGNAA) and (ii) β rays emitted from radioactive product or delayed gamma rays emitted subsequent to β decay, called conventional NAA or simply NAA. PGNAA is an online measurement method. PGNAA is complementary to conventional NAA in terms of analyzing low Z elements. Conventional NAA is an offline method and is easy to perform. Depending upon the nature of matrix and analyte to be determined, three approaches are possible in NAA namely, (i) instrumental neutron activation analysis (INAA), (ii) radiochemical neutron activation analysis (RNAA), and (iii) chemical neutron activation analysis (CNAA). Quantification is accomplished by any of the three standardisation methodologies namely (i) absolute method (ii) relative method and (iii) single comparator method. The relative method is most precise and simple to perform. Natural processes responsible for the formation of bottom sediments can be altered by anthropogenic activities. Bottom sediments are a sink as well as a source of contaminants in the aquatic environment. Analysis of-sediments provides environmentally significant

  8. Neutron activation analysis as analytical tool of environmental issue

    International Nuclear Information System (INIS)

    Otoshi, Tsunehiko

    2004-01-01

    Neutron activation analysis (NAA) ia applicable to the sample of wide range of research fields, such as material science, biology, geochemistry and so on. However, respecting the advantages of NAA, a sample with small amounts or a precious sample is the most suitable samples for NAA, because NAA is capable of trace analysis and non-destructive determination. In this paper, among these fields, NAA of atmospheric particulate matter (PM) sample is discussed emphasizing on the use of obtained data as an analytical tool of environmental issue. Concentration of PM in air is usually very low, and it is not easy to get vast amount of sample even using a high volume air sampling devise. Therefore, high sensitive NAA is suitable to determine elements in PM samples. Main components of PM is crust oriented silicate, and so on in rural/remote area, and carbonic materials and heavy metals are concentrated in PM in urban area, because of automobile exhaust and other anthropogenic emission source. Elemental pattern of PM reflects a condition of air around the monitoring site. Trends of air pollution can be traced by periodical monitoring of PM by NAA method. Elemental concentrations in air change by season. For example, crustal elements increase in dry season, and sea salts components increase their concentration when wind direction from sea is dominant. Elements that emitted from anthropogenic sources are mainly contained in fine portion of PM, and increase their concentration during winter season, when emission from heating system is high and air is stable. For further analysis and understanding of environmental issues, indicator elements for various emission sources, and elemental concentration ratios of some environmental samples and source portion assignment techniques are useful. (author)

  9. Trace element analysis in liquids by proton induced x-ray emission

    International Nuclear Information System (INIS)

    Deconninck, G.

    Proton induced x-ray emission (PIXE) from liquid has been developed for quantitative and simultaneous analysis of trace elements. Liquid drops and trickles are bombarded at atmospheric pressure, x-rays are detected in a non dispersive Si(Li) solid state detector. Absolute determinations are made by comparison with standard solutions. Detection limits in a 5 minutes run are in the ppm range for a single drop (0.05 ml). The application of this technique to the determination of trace elements in biological liquids is investigated (Cr, Mn, Fe, Co, Ni, Cu, Zn, in plant extracts, haemocyanine, albumins...). (author)

  10. Automatic data acquisition and on-line analysis of trace element concentration in serum samples

    International Nuclear Information System (INIS)

    Lecomte, R.; Paradis, P.; Monaro, S.

    1978-01-01

    A completely automated system has been developed to determine the trace element concentration in biological samples by measuring charged particle induced X-rays. A CDC-3100 computer with ADC and CAMAC interface is employed to control the data collection apparatus, acquire data and perform simultaneously the analysis. The experimental set-up consists of a large square plexiglass chamber in which a commercially available 750H Kodak Carousel is suitably arranged as a computer controlled sample changer. A method of extracting trace element concentrations using reference spectra is presented and an on-line program has been developed to easily and conveniently obtain final results at the end of each run. (Auth.)

  11. Fuzzy cluster analysis on trace elements of Hangzhou Jiaotan Guan Porcelain

    International Nuclear Information System (INIS)

    Gao Zhengyao; Liu Youe; Chen Songhua

    1997-01-01

    Forty samples of South Song 'Jiaotan Guankiln' are analyzed by neutron activation analysis (NAA). The 36 trace element contents in every sample are determined. This trace elements are analyzed by fuzzy cluster method. The result shows that the source of glaze raw material of South Song Guan porcelain is clearly different from that of the body raw material. For Guan kiln of South Song dynasty there was a very stable and lasting source of raw material of glaze and body. The archaeological problems are clarified. The glaze material and body material of modern Guan porcelain are different from those of the ancient Guan Porcelain

  12. Analysis of Hair Trace Elements in Children with Autism Spectrum Disorders and Communication Disorders.

    Science.gov (United States)

    Skalny, Anatoly V; Simashkova, Natalia V; Klyushnik, Tatiana P; Grabeklis, Andrei R; Radysh, Ivan V; Skalnaya, Margarita G; Tinkov, Alexey A

    2017-06-01

    The primary objective of the present study is analysis of hair trace elements content in children with communication disorder (CD) and autism spectrum disorder (ASD). A total of 99 children from control, CD, and ASD groups (n = 33) were examined. All children were additionally divided into two subgroups according to age. Hair levels of trace elements were assessed using inductively coupled plasma mass spectrometry. The difference was considered significant at p elements including the toxic ones, it can be proposed that children suffering from ASD are characterized by more profound alteration of metal handling and excretion in comparison to CD.

  13. Detecting errors in micro and trace analysis by using statistics

    DEFF Research Database (Denmark)

    Heydorn, K.

    1993-01-01

    By assigning a standard deviation to each step in an analytical method it is possible to predict the standard deviation of each analytical result obtained by this method. If the actual variability of replicate analytical results agrees with the expected, the analytical method is said...... to be in statistical control. Significant deviations between analytical results from different laboratories reveal the presence of systematic errors, and agreement between different laboratories indicate the absence of systematic errors. This statistical approach, referred to as the analysis of precision, was applied...

  14. 23 CFR 710.305 - Environmental analysis.

    Science.gov (United States)

    2010-04-01

    ... FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RIGHT-OF-WAY AND ENVIRONMENT RIGHT-OF-WAY AND REAL ESTATE Project Development § 710.305 Environmental analysis. The National Environmental Policy Act... agreement for acquisition of right-of-way. Where applicable, a State also must complete Clean Air Act (42 U...

  15. Determination of trace impurities in iron-based alloy using neutron activation analysis

    International Nuclear Information System (INIS)

    Zaidi, J.H.; Waheed, S.; Ahmad, S.

    2000-01-01

    A radiochemical neutron activation analysis procedure has been developed and applied to investigate 40 major, minor, and trace impurities in iron-based alloy. A comparison of RNAA and INAA indicated a significant improvement in the detection limits. The extensive use of these alloys in the heavy mechanical industry, manufacturing of aircraft engines, nuclear applications, medical devices and chemical equipment requires their precise characterization. The concentration of iron in the iron-based alloy was found to be 86.7%, whereas Ca, Cr, K, Mg, Mn, V and W were the other constituents of the alloy, which constituted to around 12.89%. The rest of the elements were present in minor or trace levels. Most of the rare earth elements were also present in trace amounts. (orig.)

  16. Charting the trends in nuclear techniques for analysis of inorganic environmental pollutants

    International Nuclear Information System (INIS)

    Braun, T.

    1986-01-01

    Publications in Analytical Abstracts in the period 1975-1984 and papers presented at the Modern Trends in Activation Analysis international conferences series in the period 1961-1986 have been used as an empirical basis for assessing general trends in research and publication activity. Some ebbs and flows in the speciality of instrumental techniques for analysis of environmental trace pollutants are revealed by a statistical analysis of the publications. (author)

  17. The trace element analysis in freshwater fish species, water and sediment in Iyidere stream (Rize-Turkey).

    Science.gov (United States)

    Verep, Bulent; Mutlu, Cengiz; Apaydin, Gokhan; Cevik, Ugur

    2012-07-15

    Many environmental problems like dam construction, agricultural debris, flooding and industrial establishments threaten Iyidere stream (Rize, Turkey) on the southeastern coast of the Black Sea (Turkey). The trace element concentrations in water, fish and sediments in lyidere stream (Rize, Turkey) were investigated in this study. The concentration of six different elements in ten freshwater fish species and sediment was determined using energy dispersive X-ray fluorescence method. A radioisotope excited X-ray fluorescence analysis using the method of multiple standard addition is applied for the elemental analysis of fish and sediments. Water samples for trace metals were analyzed using standard spectrophotometry methods. A qualitative analysis of spectral peaks showed that ten different freshwater fish samples (Chondrostoma colchicum, Chalcalburnus chalcoides, Salmo trutta labrax, Alburnoides bipunctatus, Leuciscus cephalus, Barbus taurus escherichia, Capoeta tinca, Neogobius kessleri, Rutilus frisii, Lampetra lanceolata) and sediment contained phosphorus (P), sulphur (S), chlorine (Cl), potassium (K), calcium (Ca) and titanium (Ti). Heavy metals as toxic elements for biota (Pb, Cd, Hg, Zn and Mn etc.) were not detected in fish, water and sediments. Thus, It can be declared that freshwater fish of Iyidere does not contains health risks for consumers in terms of metal pollution.

  18. Development of a new method for hydrogen isotope analysis of trace hydrocarbons in natural gas samples

    Directory of Open Access Journals (Sweden)

    Xibin Wang

    2016-12-01

    Full Text Available A new method had been developed for the analysis of hydrogen isotopic composition of trace hydrocarbons in natural gas samples by using solid phase microextraction (SPME combined with gas chromatography-isotope ratio mass spectrometry (GC/IRMS. In this study, the SPME technique had been initially introduced to achieve the enrichment of trace content of hydrocarbons with low abundance and coupled to GC/IRMS for hydrogen isotopic analysis. The main parameters, including the equilibration time, extraction temperature, and the fiber type, were systematically optimized. The results not only demonstrated that high extraction yield was true but also shows that the hydrogen isotopic fractionation was not observed during the extraction process, when the SPME device fitted with polydimethylsiloxane/divinylbenzene/carbon molecular sieve (PDMS/DVB/CAR fiber. The applications of SPME-GC/IRMS method were evaluated by using natural gas samples collected from different sedimentary basins; the standard deviation (SD was better than 4‰ for reproducible measurements; and also, the hydrogen isotope values from C1 to C9 can be obtained with satisfying repeatability. The SPME-GC/IRMS method fitted with PDMS/DVB/CAR fiber is well suited for the preconcentration of trace hydrocarbons, and provides a reliable hydrogen isotopic analysis for trace hydrocarbons in natural gas samples.

  19. Trace element analysis of teeth from pre-Columbian population groups in Mexico

    International Nuclear Information System (INIS)

    Solis, C.; Oliver, A.; Andrade, E.; Macias, R.; Mansilla, J.; Chavez-Lomeli, M.E.

    1999-01-01

    Human teeth from pre-Columbian and recent population groups have been analyzed by PIXE. Ancient teeth corresponding to children and adults were obtained from archaeological burials located in five geographic areas of Mexico. Inter-specific and inter-site differences in the trace element contents of enamel were compared in order to get some insight into differences in diet, environmental conditions, teeth health, disease state and post mortem alteration among the co-occurring populations. For permanent teeth from adults, small variations in trace element levels were found depending on the collection site or tooth health, but for deciduous teeth from children, the concentration of elements such as Mn, Fe and Sr varied considerably. In this work, the possible sources of variation are discussed. (author)

  20. Trace element analysis of old exposed air filters: a feasibility study

    International Nuclear Information System (INIS)

    Pattenden, N.J.; Fisher, E.M.R.; Bones, E.M.

    1979-10-01

    A limited number of old exposed air filters from a network of sampling stations extending the length of North and South America have been analysed for many trace elements. (The network is run by the United States Department of Energy Environmental Measurements Laboratory). The objective was to assess the possible value of a large program of such measurements for providing information on the trace element concentrations in airborne particulates existing at the time of sample collection. On the basis of the evidence obtained, it is considered that valid information could be extracted in this way. In view of the extent of the store of old filters, which cover about a 10 year period up to the present day from stations spread over the North and South American continents and elsewhere, such a program appears to be well worthwhile. (author)

  1. Trace drug analysis by surface-enhanced Raman spectroscopy

    Science.gov (United States)

    Farquharson, Stuart; Lee, Vincent Y.

    2000-12-01

    Drug overdose involves more than 10 percent of emergency room (ER) cases, and a method to rapidly identify and quantify the abused drug is critical to the ability of the ER physician to administer the appropriate care. To this end, we have been developing a surface-enhanced Raman (SER) active material capable of detecting target drugs at physiological concentrations in urine. The SER-active material consists of a metal-doped sol-gel that provides not only a million fold increase in sensitivity but also reproducible measurements. The porous silica network offers a unique environment for stabilizing SER active metal particles and the high surface area increase the interaction between the analyte and metal particles. The sol-gel has been coated on the inside walls of glass samples vials, such that urine specimens may simply be introduced for analysis. Here we present the surface-enhanced Raman spectra of a series of barbiturates, actual urine specimens, and a drug 'spiked' urine specimen. The utility of pH adjustment to suppress dominant biochemicals associated with urine is also presented.

  2. Essential trace elements in edible mushrooms by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Patricia L.C.; Maihara, Vera A.; Castro, Lilian P. de [Instituto de Pesquisa e Energetica e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: patricialandim@ig.com.br; vmaihara@ipen.br; lilian.Pavanelli@terra.com.br; Figueira, Rubens C.L. [Universidade Cruzeiro do Sul, Sao Paulo, SP (Brazil)]. E-mail: figueiraru@yahoo.com.br

    2007-07-01

    Mushrooms are excellent nutritional sources since they provide proteins, fibers and mineral, such as K, P, Fe. They have also been the focus of medical research. In Brazil mushrooms are not consumed in large quantities by the general population since people know little about the nutritional and medicinal benefits that mushrooms offer. Hence, this study intends to contribute to a better understanding of the essential element content in edible mushrooms, which are currently commercialized in Sao Paulo state. Br Fe, K, Na and Zn concentrations were determined by Instrumental Neutron Activation Analysis in the following mushroom species: Shitake (Lentinus edodes), Shimeji (Pleurotus ssp), Paris Champignon (Agaricus bisporus), Hiratake ( Pleurotus ssp) and Eringue (Pleurotus Eryngu. The mushroom samples were acquired from commercial establishments in the city of Sao Paulo and directly from the producers. Essential element contents in mushrooms varied between Br 0.03 to 4.1 mg/kg; Fe 20 to 267 mg/kg; K 1.2 to 5.3 g/kg, Na 10 to 582 mg/kg and Zn 60 to 120 mg/kg. The results confirm that mushrooms can be considered a good source of K, Fe and Zn. The low Na level is a good nutritional benefit for the consumer. (author)

  3. Application of the neutron activation analysis method for determing trace elements in Brazilian food sample

    International Nuclear Information System (INIS)

    Maihara, V.A.; Vasconcellos, M.B.A.

    1988-01-01

    Recently there has been an increase of consciousness about the importance of trace elements in human health and disease as well as rising concern about food contamination. The development of sensitive, accurate and price methods is one of the most important of the knowledge of trace elements contents in foods and in biological samples. Neutron activation analysis is one of the most suitable tecniques because a great number of elements can be determined in concentrations in the range of μg/g to ng/g. The present work is a part of an AIEA Co-ordinated Research Programme on the applications of nuclear techniques for toxic elements in foodstuffs. Neutron activation analysis is applied to analysis of bread, milk powder and rice that are considered essential foods in the Brazilian diet. Some aspects of the activation analysis of biological matrices are discussed. (author) [pt

  4. Preconcentration of trace elements

    International Nuclear Information System (INIS)

    Zolotov, Yu. A.; Kuz'min, N.M.

    1990-01-01

    This monograph deals with the theory and practical applications of trace metals preconcentration. It gives general characteristics of the process and describes in detail the methods of preconcentration: solvent extraction, sorption, co-precipitation, volatilization, and others. Special attention is given to preconcentration in combination with subsequent determination methods. The use of preconcentration in analysis of environmental and biological samples, mineral raw materials, high purity substances, and various industrial materials is also considered

  5. High precision analysis of trace lithium isotope by thermal ionization mass spectrometry

    International Nuclear Information System (INIS)

    Tang Lei; Liu Xuemei; Long Kaiming; Liu Zhao; Yang Tianli

    2010-01-01

    High precision analysis method of ng lithium by thermal ionization mass spectrometry is developed. By double-filament measurement,phosphine acid ion enhancer and sample pre-baking technique,the precision of trace lithium analysis is improved. For 100 ng lithium isotope standard sample, relative standard deviation is better than 0.086%; for 10 ng lithium isotope standard sample, relative standard deviation is better than 0.90%. (authors)

  6. Extraction of trace nitrophenols in environmental water samples using boronate affinity sorbent

    International Nuclear Information System (INIS)

    Zhang, Yong; Mei, Meng; Huang, Xiaojia; Yuan, Dongxing

    2015-01-01

    In this research, the applicability of a new sorbent based on boronate affinity material is demonstrated. For this purpose, six strong polar nitrophenols were selected as models which are difficult to be extracted in neutral form (only based on hydrophobic interactions). The extracted nitrophenols were separated and determined by high-performance liquid chromatography with diode array detection. The sorbent was synthesized by in situ copolymerization of 3-acrylamidophenylboronic acid and divinylbenzene using dimethyl sulfoxide and azobisisobutyronitrile as porogen solvent and initiator, respectively. The effect of the preparation parameters in the polymerization mixture on extraction performance was investigated in detail. The size and morphology of the sorbent have been characterized via different techniques such as infrared spectroscopy, elemental analysis, scanning electron microscopy and mercury intrusion porosimetry. The important parameters influencing the extraction efficiency were studied and optimized thoroughly. Under the optimum extraction conditions, the limits of detection (S/N = 3) and limits of quantification (S/N = 10) for the target nitrophenols were 0.097–0.28 and 0.32–0.92 μg/L, respectively. The precision of the proposed method was evaluated in terms of intra- and inter-assay variability calculated as RSD, and it was found that the RSDs were all below 9%. Finally, the developed method was successfully applied for environmental water samples such as wastewater, tap, lake and river water. The recoveries varied within the range of 71.2–115% with RSD below 11% in all cases. The results well demonstrate that the new boronate affinity sorbent can extract nitrophenols effectively through multi-interactions including boron–nitrogen coordination, hydrogen-bond and hydrophobic interactions between sorbent and analytes. - Highlights: • A new boronate affinity sorbent (BAS) was prepared. • The BAS was used as the extractive medium of stir

  7. Neutron activation analysis applied to the determination of trace elements in human nails

    International Nuclear Information System (INIS)

    Aguiar, Amilton Reinaldo

    2001-01-01

    There is a considerable interest in the determination of trace elements in human nails in order to use this tissue as a monitor of nutritional and healthy status of individuals, of occupational exposure diseases and of the environmental contamination. In this work, instrumental neutron activation analysis was applied to determine trace elements in finger nail clippings to make comparisons between the elemental concentrations obtained in nails from healthy individuals of a control group and those from cystic fibrosis (CF) patients. Firstly, a protocol for sample collection and preparation for analysis was established. Finger and toe nail samples from CF patients were collected at the Instituto da Crianca of Medicine School, University of Sao Paulo, SP. The nail samples from control group were collected from healthy adults and from children living in Sao Paulo city, SP. These samples were cleaned by stirring them witha a diluted Triton X100 solution and then by washing with distilled water and acetone. The analytical procedure consisted of irradiation nail samples and elemental standards in the IEA-R1m nuclear reactor under thermal neutro flux of about 10 12 n cm -2 s -1 , for short and long period irradiations. The activities of the radionuclides were measured using a gamma-ray spectrometer comprising an hyperpure Ge detector and associated electronic system. The biological reference materials Bovine Liver 1577b and Oyster Tissue 1566a, both from National Institute of Standards and Technology, USA were analysed in order to evaluate the accuracy and precision of the results. The analysis of variance (ANOVA) and F-test at the significance level of 5% were used to make a comparison between the sets of results obtained in this work. In the comparison of the results obtained for finger and toe nails from CF patients, the Br concentrations were higher in finger nails that those obtained for toe nails. For the control group of children, the finger nails presented different

  8. Comparing Distributions of Environmental Outcomes for Regulatory Environmental Justice Analysis

    Directory of Open Access Journals (Sweden)

    Glenn Sheriff

    2011-05-01

    Full Text Available Economists have long been interested in measuring distributional impacts of policy interventions. As environmental justice (EJ emerged as an ethical issue in the 1970s, the academic literature has provided statistical analyses of the incidence and causes of various environmental outcomes as they relate to race, income, and other demographic variables. In the context of regulatory impacts, however, there is a lack of consensus regarding what information is relevant for EJ analysis, and how best to present it. This paper helps frame the discussion by suggesting a set of questions fundamental to regulatory EJ analysis, reviewing past approaches to quantifying distributional equity, and discussing the potential for adapting existing tools to the regulatory context.

  9. The Determination Of Trace Element Levels In Diet By Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Kukuh, Ratnawati; Djojosubroto, Harjoto

    2002-01-01

    Trace element levels in foodstuff are normally low. Although the levels are low, certain trace elements which are called essential trace elements have an important role in metabolism process. Deficiency or intoxication of essential trace elements may lead to abnormal health. In this study the levels of Zn, Fe, AI, Mn, and Co in diet samples were determined by neutron activation analysis, and then the daily intakes of these elements were estimated. The samples were prepared by duplicate diet method, representing those that were consumed by population from West, Central and East Java. Following the collection the respective samples were blended, then were freeze dried at-54 o c. The elemental quantification were performed by neutron activation analysis. The traceability of the determination was ensured using standard reference material NIST-SRM-1548a. The results show that the daily intake for Zn were 2.8-22.8 mg/day (reference value were 5- 40 mg/day), Fe were 3.1-26.5 mg/day (reference value were 6-40 mg/day), AI were 4,2-32.9 mg/day (reference value were 2-45 mg/day), Mn were 1.0-5,6 mg/day (reference value were 0.4-10,0 mg/day), and Co were 0,005-0,074 mg/day (reference value were 0.005 -1.8 mg/day

  10. Trace metals of an acid mine drainage stream using a chemical model (WATEQ) and sediment analysis

    International Nuclear Information System (INIS)

    West, K.A.; Wilson, T.P.

    1992-01-01

    The high metal contents common to the discharge of acid-mine drainage (AMD) from mines and mine spoils is an environmental concern to both government and industry. This paper reports the results of investigation of the behavior of metals in an AMD system at a former surface coal mine in Tuscarawas County, Oh. AMD discharges from seeps travels, in respective order through a laminar flow stream; a Typha-dominated wetland; a turbulent flow stream; and a sediment retention pond. Dissolved metals (Fe, Mn, Zn, Cr, Cd, Cu, and Al) major and minor components, and other parameters (pH, dissolved oxygen and Eh) were measured in the AMD water at each sample location. A chemical mineral equilibrium model (WATEQ) was used to predict the minerals which should precipitate at each site. Results suggest that the seeps are supersaturated and should be precipitating hematite, goethite and magnetite (iron oxides), and siderite (iron carbonate), whereas water of the other downstream sites were at or below equilibrium conditions for these minerals. The hydrogeochemistry of the AMD was further studied using sequential chemical attacks on the precipitate sediment surface coatings, in order to determine metal concentrations in the exchangeable, carbonate, Fe-Mn oxyhydroxide, and oxidizable fractions. The carbonate and exchangeable fractions of the precipitate are dominated by Ca and Fe, as well as Mg in the carbonate fraction. The Fe-Mn oxyhydroxide fraction contained Fe, Al, Mn, Mg, and trace metals, and also contained the greatest concentration of total elements in the system. The Fe-Mn oxyhydroxide is therefore, the major sink for metals of this AMD system. The decrease in the concentration of metals in the sediment precipitates in the downstream locations, is consistent with WATEQ and water analysis results

  11. Full spectrum analysis in environmental monitoring

    International Nuclear Information System (INIS)

    Reinhardt, Sascha; Hartmann, Soeren; Pimpl, Richard

    2015-01-01

    In the environmental monitoring spectroscopic gamma detectors are frequently used. The motivation to use spectroscopic gamma detectors is the higher sensitivity and specific spectral information. For the analysis often the photo peaks of the gamma spectrum are used to identify the nuclide. These methods are very reliable, robust and well developed but using only the photo peak means also to use only a fraction of the available information. Doing a full spectrum analysis based on principle components obtained from NASVD for description of the radiation background and adjustment calculations are a possible analysis method which may provide advantages compared to a peak based analysis when used for a continuous environmental monitoring. An analysis example is shown and discussed with a measured time series of gamma spectra obtained from a spectroscopic gamma detector SARA IGS710 with a NaI(Tl) scintillator as it is used in the environmental monitoring.

  12. Full spectrum analysis in environmental monitoring

    International Nuclear Information System (INIS)

    Reinahrdt, S.; Hartmann, S.; Pimpl, R.

    2014-01-01

    In the environmental monitoring spectroscopic gamma detectors are frequently used. The motivation to use spectroscopic gamma detectors is the higher sensitivity and specific spectral information. For the analysis often the photo peaks of the gamma spectrum are used to identify the nuclide. These methods are very reliable, robust and well developed but using only the photo peak means also to use only a fraction of the available information. Doing a full spectrum analysis based on principal components obtained from NASVD for description of the radiation background and adjustment calculations are a possible analysis method, which may provide advantages compared to a peak based analysis when used for a continuous environmental monitoring. An analysis example is shown and discussed with a measured time series of gamma spectra obtained from a spectroscopic gamma detector SARA IGS710 with a NaI(Tl) scintillator as it is used in the environmental monitoring. (authors)

  13. Graphene-based solid-phase extraction disk for fast separation and preconcentration of trace polycyclic aromatic hydrocarbons from environmental water samples.

    Science.gov (United States)

    Wang, Zonghua; Han, Qiang; Xia, Jianfei; Xia, Linhua; Ding, Mingyu; Tang, Jie

    2013-06-01

    Graphene has great potentials for the use in sample preparation due to its ultra high specific surface area, superior chemical stability, and excellent thermal stability. In our work, a novel graphene-based SPE disk was developed for separation and preconcentration of trace polycyclic aromatic hydrocarbons from environmental water samples. Based on the strong π-π stacking interaction between the analytes and graphene, the analytes extracted by graphene were eluted by cyclohexane and then determined by GC-MS. Under the optimized conditions, high flow rate (30 mL/min) and sensitivity (0.84-13 ng/L) were achieved. The proposed method was successfully applied to the analysis of real environmental water samples with recoveries ranging from 72.8 to 106.2%. Furthermore, the property of anticlogging and reusability was also improved. This work reveals great potentials of graphene-based SPE disk in environmental analytical. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Food for Thought: A Critical Overview of Current Practical and Conceptual Challenges in Trace Element Analysis in Natural Waters

    Directory of Open Access Journals (Sweden)

    Montserrat Filella

    2013-07-01

    Full Text Available The practical and conceptual challenges faced by the analysis of trace elements present in natural waters are not merely, as is often thought, an endless race towards lower detection limits or to the development of techniques allowing the determination of any possible chemical species formed by all chemical elements. Rather, as discussed in this paper, they include the development of (i robust, cheap, and reliable methods that could also be used by laypeople (the experience gained in the development of field kits for As is discussed as an example from which similar developments for other elements may be drawn; (ii more environmentally-friendly methods (the current guiding criteria probably being too simplistic; and (iii methods making it possible to follow diel concentration changes and sharp concentration variations caused by the probable increase of heavy rainfall events. This paper also claims that neither the measurement of total concentrations (reliable methods are lacking for many elements of the periodic table of trace elements, as illustrated through the cases of Bi, Te, and Sb, nor chemical speciation analysis, are as mature as often thought. In particular, chemical speciation studies demand the development of a better, comprehensive conceptual framework. A trial is carried out to lay the basis of such a framework.

  15. Trace elements in several species of crustaceans of Amami Island Group in Japan determined by activation analysis

    International Nuclear Information System (INIS)

    Fukushima, M.; Tamate, H.; Nakano, Y.

    2001-01-01

    Concentration levels of trace elements were determined in several species of subtropical crustaceans from Amami Islands in Japan in order to evaluate the levels of specific accumulation of elements among species. Tissue samples prepared from gill, muscle, hepatopancreas, and testis were irradiated for photon activation analysis (PAA) and neutron activation analysis (NAA). By PAA and NAA, eighteen elements could be determined. The levels of Br and I were extremely high in gills of spiny lobster and shovel-nosed lobster, respectively. A high concentration of Ag was found in the hepatopancreas of spiny lobsters collected from the Amami Island, while this element was not detected in the same species collected from Toba. The results suggest that the distribution of the trace elements in different tissues and species varies according to both species and environmental differences. To study the molecular forms of the elements in tissue, fractions that contained protein-bound elements from the hepatopancreas of spiny lobsters were separated by ultracentrifugation and gel filtration chromatography. Elution profiles of the chromatography suggest that Cu, Fe, and Se were bound to proteins, while Ag was not. (author)

  16. Carbon Dioxide Information Analysis Center and World Data Center-A for atmospheric trace gases: FY 1993 activities

    Energy Technology Data Exchange (ETDEWEB)

    Cushman, R.M. [Oak Ridge National Lab., TN (United States). Carbon Dioxide Information Analysis Center; Stoss, F.W. [Oak Ridge National Lab., TN (United States). Carbon Dioxide Information Analysis Center]|[Univ. of Tennessee, Knoxville, TN (United States). Energy, Environment, and Resources Center

    1994-01-01

    During the course of a fiscal year, Oak Ridge National Laboratory`s Carbon Dioxide Information Analysis Center (CDIAC) distributes thousands of specialty publications-numeric data packages (NDPs), computer model packages (CMPs), technical reports, public communication publications, newsletters, article reprints, and reference books-in response to requests for information related to global environmental issues, primarily those pertaining to climate change. CDIAC`s staff also provide technical responses to specific inquiries related to carbon dioxide (CO{sub 2}), other trace gases, and climate. Hundreds of referrals to other researchers, policy analysts, information specialists, or organizations are also facilitated by CDIAC`s staff. This report provides an account of the activities accomplished by CDIAC (including World Data Center-A for Atmospheric Trace Gases) during the period October 1, 1992, to September 30, 1993. An organizational overview of CDIAC and its staff is supplemented by a detailed description of inquiries received and CDIAC`s response to those inquiries. An analysis and description of the preparation and distribution of NDPS, CMPS, technical reports, newsletters, fact sheets, specialty publications, and reprints are provided. Comments and descriptions of CDIAC`s information management systems, professional networking, and special bilateral agreements are also presented.

  17. Carbon Dioxide Information Analysis Center and World Data Center-A for atmospheric trace gases: FY 1993 activities

    International Nuclear Information System (INIS)

    Cushman, R.M.; Stoss, F.W.; Univ. of Tennessee, Knoxville, TN

    1994-01-01

    During the course of a fiscal year, Oak Ridge National Laboratory's Carbon Dioxide Information Analysis Center (CDIAC) distributes thousands of specialty publications-numeric data packages (NDPs), computer model packages (CMPs), technical reports, public communication publications, newsletters, article reprints, and reference books-in response to requests for information related to global environmental issues, primarily those pertaining to climate change. CDIAC's staff also provide technical responses to specific inquiries related to carbon dioxide (CO 2 ), other trace gases, and climate. Hundreds of referrals to other researchers, policy analysts, information specialists, or organizations are also facilitated by CDIAC's staff. This report provides an account of the activities accomplished by CDIAC (including World Data Center-A for Atmospheric Trace Gases) during the period October 1, 1992, to September 30, 1993. An organizational overview of CDIAC and its staff is supplemented by a detailed description of inquiries received and CDIAC's response to those inquiries. An analysis and description of the preparation and distribution of NDPS, CMPS, technical reports, newsletters, fact sheets, specialty publications, and reprints are provided. Comments and descriptions of CDIAC's information management systems, professional networking, and special bilateral agreements are also presented

  18. Fast and sensitive trace analysis of malachite green using a surface-enhanced Raman microfluidic sensor.

    Science.gov (United States)

    Lee, Sangyeop; Choi, Junghyun; Chen, Lingxin; Park, Byungchoon; Kyong, Jin Burm; Seong, Gi Hun; Choo, Jaebum; Lee, Yeonjung; Shin, Kyung-Hoon; Lee, Eun Kyu; Joo, Sang-Woo; Lee, Kyeong-Hee

    2007-05-08

    A rapid and highly sensitive trace analysis technique for determining malachite green (MG) in a polydimethylsiloxane (PDMS) microfluidic sensor was investigated using surface-enhanced Raman spectroscopy (SERS). A zigzag-shaped PDMS microfluidic channel was fabricated for efficient mixing between MG analytes and aggregated silver colloids. Under the optimal condition of flow velocity, MG molecules were effectively adsorbed onto silver nanoparticles while flowing along the upper and lower zigzag-shaped PDMS channel. A quantitative analysis of MG was performed based on the measured peak height at 1615 cm(-1) in its SERS spectrum. The limit of detection, using the SERS microfluidic sensor, was found to be below the 1-2 ppb level and this low detection limit is comparable to the result of the LC-Mass detection method. In the present study, we introduce a new conceptual detection technology, using a SERS microfluidic sensor, for the highly sensitive trace analysis of MG in water.

  19. Trace elements in high purity materials for advanced technology: contribution of neutron activation analysis and radioanalytical technique

    International Nuclear Information System (INIS)

    Gallorini, M.; Pietra, R.; Sabbioni, E.

    1991-01-01

    Neutron activation analysis and radioanalytical techniques have been employed to investigate problems related to trace elements and high purity technology materials. Applications of these techniques are overviewed: semiconductor technology as in the case of As and In ion implantation in high purity silicon; problems related to trace elements impurities in thermometric measurements; coating materials to prevent trace elements contamination in biological sampling and metals release from human prostheses. (author) 8 refs.; 2 figs.; 8 tabs

  20. Tracing distant environmental impacts of agricultural products from a consumer perspective

    NARCIS (Netherlands)

    Kastner, Thomas; Kastner, Michael; Nonhebel, Sanderine

    2011-01-01

    Globally, trade flows of agricultural products are increasing. While value is typically added along the whole production chain, certain environmental impacts, such as land and water use, biomass appropriation, and soil degradation, are intrinsically linked to where the primary products originate

  1. Data analysis and interpretation for environmental surveillance

    International Nuclear Information System (INIS)

    1992-06-01

    The Data Analysis and Interpretation for Environmental Surveillance Conference was held in Lexington, Kentucky, February 5--7, 1990. The conference was sponsored by what is now the Office of Environmental Compliance and Documentation, Oak Ridge National Laboratory. Participants included technical professionals from all Martin Marietta Energy Systems facilities, Westinghouse Materials Company of Ohio, Pacific Northwest Laboratory, and several technical support contractors. Presentations at the conference ranged the full spectrum of issues that effect the analysis and interpretation of environmental data. Topics included tracking systems for samples and schedules associated with ongoing programs; coalescing data from a variety of sources and pedigrees into integrated data bases; methods for evaluating the quality of environmental data through empirical estimates of parameters such as charge balance, pH, and specific conductance; statistical applications to the interpretation of environmental information; and uses of environmental information in risk and dose assessments. Hearing about and discussing this wide variety of topics provided an opportunity to capture the subtlety of each discipline and to appreciate the continuity that is required among the disciplines in order to perform high-quality environmental information analysis

  2. Trace substances in landfill gases. Evaluation and meaningful analysis. Spurenstoffe in Deponiegasen. Bewertung und sinnvolle Analyse

    Energy Technology Data Exchange (ETDEWEB)

    Eisenmann, R [Karlsruhe Univ. (T.H.) (Germany, F.R.). Engler-Bunte-Institut

    1989-06-01

    Many of the innumerable substances which may occur in landfill gases are to be considered as possibly dangerous; they lead to environmental problems due to their malodour or noxious combustion products. With respect to the evaluation of the traces of substances there is great unsecurity and often extreme requirements as to volume and quality of gas analyses have to be met. Generally it can be noticed that there are hazards emanating from landfill gases, but in comparison to other risks they are not excessive. The contribution shall help to clarify questions and furnish a basis for the practice-oriented and appropriate landfill gas analytics. (orig.).

  3. Trace determination of 90Sr and 89Sr in environmental samples by collinear resonance ionization spectroscopy

    International Nuclear Information System (INIS)

    Lantzsch, J.; Bushaw, B. A.; Bystrow, V. A.; Herrmann, G.; Kluge, H.-J.; Niess, S.; Otten, E. W.; Passler, G.; Schwalbach, R.; Schwarz, M.; Stenner, J.; Trautmann, N.; Wendt, K.; Yushkevich, Y. V.; Zimmer, K.

    1995-01-01

    Collinear resonance ionization spectroscopy has been developed as a sensitive technique for fast trace detection of 90 Sr and 89 Sr in the environment. A detection limit for 90 Sr of 10 7 atoms in the presence of 10 17 atoms in the presence of 10 17 atoms of stable Strontium has been achieved, while the applicability of the method has been demonstrated on real world samples. After collection and chemical separation, strontium is surface ionized, accelerated to 33keV and mass separated. The ions are neutralized and the emerging fast atoms interact with an argon ion laser beam (γ=364 nm) in a quasi-collinear geometry. Optical excitation starts from the long-lived 5s4d 3 D2 state of strontium, which is populated in the charge exchange process, and the fast atoms are selectively excited into the high-lying 5s23f 3 F3 Rydberg state. The Rydberg-atoms are subsequently field-ionized and detected by a channeltron detector after energy selection. The described method was successfully used to determine the 90 Sr-content in air samples collected near Munich during the Chernobyl reactor accident in April 1986

  4. Analysis procedure for americium in environmental samples

    International Nuclear Information System (INIS)

    Holloway, R.W.; Hayes, D.W.

    1982-01-01

    Several methods for the analysis of 241 Am in environmental samples were evaluated and a preferred method was selected. This method was modified and used to determine the 241 Am content in sediments, biota, and water. The advantages and limitations of the method are discussed. The method is also suitable for 244 Cm analysis

  5. Major and Trace Element Analysis of Natural and Experimental Igneous Systems using LA-ICP-MS

    Science.gov (United States)

    Jenner, Frances E.; Arevalo, Ricardo D., Jr.

    2016-01-01

    Major- and trace-element compositions of minerals provide valuable information on a variety of global Earth-system processes, including melting of distinct mantle reservoirs, the growth and evolution of the Earths crust and the formation of economically viable ore deposits. In the mid-1980s and early 1990s, attempts were made to couple laser ablation (LA) systems to inductively coupled plasma mass spectrometry (ICPMS) instruments (e.g. Fryer et al. 1995; Jackson et al. 1992). The goal was to develop a rapid, highly sensitive in situ analytical technique to measure abundances and spatial distributions of trace elements in minerals and other geological samples. Elemental analysis using LAICPMS was envisaged as a quicker and less destructive means of chemical analysis (requiring only g quantities) than labour-intensive sample digestion and solution analysis (requiring mg-levels of material); and it would be a more cost-effective method than secondary ion mass spectrometry (SIMS) for the routine analysis of trace elements from solid samples. Furthermore, it would have lower limits-of-detection than electron probe microanalysis (EPMA) (e.g. Jackson et al. 1992; Eggins 2003).

  6. Determination of trace elements in dried sea-plant homogenate (SP-M-1) and in dried copepod homogenate (MA-A-1) by means of neutron activation analysis

    International Nuclear Information System (INIS)

    Tjioe, P.S.; Goeij, J.J.M. de; Bruin, M. de.

    1977-07-01

    Two marine environmental reference materials were investigated in an intercalibration study of trace elements. According to the specifications from the International Laboratory of Marine Radioactivity at Monaco two samples, a sea-plant homogenate and a copepod homogenate, were analysed by neutron activation analysis. The results of the trace-element analyses were based on dry weight. The moisture content was measured on separate aliquots. For the intercalibration study the following elements were listed as elements of primary interest: mercury, cadmium, lead, manganese, zinc, copper, chromium, silver, iron and nickel. For the 14 elements normally analysed with the routine destructive method, the element gold could not be measured in the two marine samples. This was due to the high residual bromine-82 activity in fraction 13, which contains gold that distills over. With the nondestructive method, nine elements could be assessed, of which only three coincide with the 14 elements of the destructive method. A survey of all measured (trace) elements is presented. The 20 (trace) elements measured in the sea-plant homogenate and in the copepod homogenate comprise 8 out of the 10 trace elements of primary interest, all 5 trace elements of secondary interest (arsenic, cobalt, antimony, selenium and vanadium), and 5 additional (trace) elements. The trace-element determination in both marine biological materials via the destructive procedure was carried out in twelve-fold. In the nondestructive procedure quadruple measurements were performed. For all trace-element levels analysed an average value was calculated

  7. Critical review of forensic trace evidence analysis and the need for a new approach.

    Science.gov (United States)

    Stoney, David A; Stoney, Paul L

    2015-06-01

    The historical development, contributions and limitations of the two traditional approaches to trace evidence analysis are reviewed. The first approach was as generalist practitioner, looking broadly at an assemblage of many different particle types. The second was that of specialist practitioner, with attention focused on one specific particle type. Four factors have significantly impacted the effectiveness of these approaches: (1) increasing technological capabilities, (2) increasing complexity in the character of manufactured materials, (3) changes in forensic laboratory management, and (4) changing scientific and legal expectations. The effectiveness of each approach is assessed within the context of these changes. More recently, new technologies have been applied to some trace evidence problems, intended to address one or more limitations. This has led to a third approach founded on discrete, highly technical methods addressing specific analytical problems. After evaluating the contributions and limitations of this third approach, we consider the different ways that technologies could be developed to address unmet needs in forensic trace evidence analysis. The route toward effective use of new technologies is contrasted with how forensic science laboratories are currently choosing and employing them. The conclusion is that although new technologies are contributing, we are not on a path that will result in their most effective and appropriate use. A new approach is required. Based on an analysis of the contributions of each of the three exisiting approaches, seven characteristics of an effective trace evidence analysis capability were determined: (1) particle traces should be a major problem-solving tool, (2) there should be readily available, straightforward methods to enable their use, (3) all available and potentially useful particle types should be considered, (4) decisions to use them should be made in the context of each case, guided by what they can

  8. Alleviation of environmental risks associated with severely contaminated mine tailings using amendments: Modeling of trace element speciation, solubility, and plant accumulation.

    Science.gov (United States)

    Pardo, Tania; Bes, Cleménce; Bernal, Maria Pilar; Clemente, Rafael

    2016-11-01

    Tailings are considered one of the most relevant sources of contamination associated with mining activities. Phytostabilization of mine spoils may need the application of the adequate combination of amendments to facilitate plant establishment and reduce their environmental impact. Two pot experiments were set up to assess the capability of 2 inorganic materials (calcium carbonate and a red mud derivate, ViroBind TM ), alone or in combination with organic amendments, for the stabilization of highly acidic trace element-contaminated mine tailings using Atriplex halimus. The effects of the treatments on tailings and porewater physico-chemical properties and trace-element accumulation by the plants, as well as the processes governing trace elements speciation and solubility in soil solution and their bioavailability were modeled. The application of the amendments increased tailings pH and decreased (>99%) trace elements solubility in porewater, but also changed the speciation of soluble Cd, Cu, and Pb. All the treatments made A. halimus growth in the tailings possible; organic amendments increased plant biomass and nutritional status, and reduced trace-element accumulation in the plants. Tailings amendments modified trace-element speciation in porewater (favoring the formation of chlorides and/or organo-metallic forms) and their solubility and plant uptake, which were found to be mainly governed by tailing/porewater pH, electrical conductivity, and organic carbon content, as well as soluble/available trace-element concentrations. Environ Toxicol Chem 2016;35:2874-2884. © 2016 SETAC. © 2016 SETAC.

  9. Trace element analysis in the serum and hair of Antarctic leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Rachael [Faculty of Veterinary Science, University of Sydney, NSW 2006 Australia (Australia); Australian Marine Mammal Research Centre PO Box 20 Mosman, NSW 2088 (Australia)], E-mail: rgray@vetsci.usyd.edu.au; Canfield, Paul [Faculty of Veterinary Science, University of Sydney, NSW 2006 (Australia); Rogers, Tracey [Australian Marine Mammal Research Centre PO Box 20 Mosman, NSW 2088 (Australia); Evolution and Ecology Research Centre and School of Biological Earth and Environmental Sciences, University of New South Wales, NSW 2052 (Australia)

    2008-07-25

    Leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii, occupy an upper trophic level within the Antarctic ecosystem and are useful indicator species in the Southern Ocean of trace element concentrations. Reference values for the concentration of 19 trace elements were determined in the serum and hair of leopard and Weddell seals sampled in Eastern Antarctica. These reference values can be used as 'baseline' levels for monitoring trace element concentrations in these species. Greater trace element concentrations were determined in hair compared to serum, indicating different time scales of trace element accumulation in these samples. For the majority of trace elements, except for Se in the leopard seal samples and Cr in the Weddell seal samples, significant regression relationships for trace element concentrations in hair and serum were not elucidated. Significant differences were determined in the concentrations of seven out of 15 elements with hair type, moult and new, in the leopard seal; concentrations in moult hair were determined to be greater than in new hair for all elements except Zn. Hair analysis was determined to be useful for monitoring exposure to trace elements and when collected off the ice from moulting seals, hair can be employed as a non-invasive sample for trace element analysis in leopard and Weddell seals.

  10. Trace elemental composition of Nigerian coal measured by neutron activation analysis

    International Nuclear Information System (INIS)

    Ndiokwere, Ch.L.; Guinn, V.P.; Burtner, D.

    1983-01-01

    The instrumental neutron activation analysis (INAA) technique has been used to determine 17 major, minor and trace elements in samples of the three major sources of Nigerian coal. The NBS Standard Reference Material, Coal SRM 1632, was also analyzed, for the purpose of verifying the accuracy of the method. The concentrations of the major elements determined for the Nigerian coal were found to be much lower than the mean values of those reported for coal samples from other parts of the world. (author)

  11. Determination of trace elements in a cigarette paper by neutron activation analysis

    International Nuclear Information System (INIS)

    Abedinzadeh, Z.; Khalkhali, Zh.; Razeghi, M.; Parsa, B.

    The concentration of 19 trace elements in a cigarette paper (Zig-Zag Paper Company, France) which is used in making different brands of Iranian cigarettes, has been measured by neutron activation analysis, employing a high-resolution Ge(Li) detector. They include Na, K, Ca, Sc, Cr, Mn, Fe, Co, Zn, Br, Sr, Sb, Ba, Ce, Eu, Gd, Au, Hg, and Th. (author)

  12. Determination of trace element impurities in aspirin tablets by neutron activation analysis

    International Nuclear Information System (INIS)

    Iskander, F.Y.; Klein, D.E.; Bauer, T.L.

    1986-01-01

    Twenty-five trace and minor elements in five different Egyptian aspirin brands (Aspo, Askin, Aspocid, Aspeol and Rivo) were determined by instrumental neutron activation analysis. It was concluded that the concentration of As, Ba, Br, Co, Cr, Fe (except in Aspocid), Mg, Mn, Rb, Se, Sr and Zn in the Egyptian brands is below or within the concentration range reported for these elements in 16 American aspirin and aspirin-like brands. (author)

  13. An Angiotensin II type 1 receptor activation switch patch revealed through Evolutionary Trace analysis

    DEFF Research Database (Denmark)

    Bonde, Marie Mi; Yao, Rong; Ma, Jian-Nong

    2010-01-01

    to be completely resolved. Evolutionary Trace (ET) analysis is a computational method, which identifies clusters of functionally important residues by integrating information on evolutionary important residue variations with receptor structure. Combined with known mutational data, ET predicted a patch of residues......) displayed phenotypes associated with changed activation state, such as increased agonist affinity or basal activity, promiscuous activation, or constitutive internalization highlighting the importance of testing different signaling pathways. We conclude that this evolutionary important patch mediates...

  14. X-ray fluorescence analysis for trace element determination in foodstuff chemistry

    International Nuclear Information System (INIS)

    Wildanger, W.

    The physical fundamentals of X-ray fluorescence analysis are given and the routine spectrometers described. The basic principles are given of analytical methods used in qualitative and quantitative fluorescence analyses. Examples are given of the use of the method in a number of fields and the possibility and usefulness is discussed for the determination of trace elements in foodstuffs. The preparation of samples, preliminary concentration of components and calibration methods are discussed. (M.K.)

  15. Determination of trace elements in chewing gum by neutron activation analysis

    International Nuclear Information System (INIS)

    Dietz, M.L.

    1990-01-01

    Six trace elements of nutritional or toxicological interest (Al, Ca, Cl, Mn, Na and Sr) were determined in three different brands of chewing gum by instrumental neutron activation analysis. For the particular brands of gum examined, none of the detected elements was found to be present at a level representing a substantial contribution to the total dietary intake of the element for an American adult. (author) 11 refs.; 3 tabs

  16. Correction for interelement effect in X-Ray fluorescence analysis of trace elements in geological materials

    International Nuclear Information System (INIS)

    El-Behay, A.Z.; Attawiya, M.Y.; Khattab, F.M.

    1984-01-01

    In a trial to obtain accurate results from X-ray fluorescence technique for the analysis of trace elements in geological materials, two corrections were used for the obtained data, namely, correction for the observed x-ray intensities for absorption and/or enhancement effects due to the presence of other elements in the system and correction for spectral deconvolution to account for the overlapping lines. Significant improvement in the precision and accuracy was obtained and evaluated

  17. Analysis of trace elements by means of accelerator secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Ender, R.M.

    1997-01-01

    The analysis of material composition and trace element concentration is of increasing interest primarily in semiconductor technology but also in metallurgy, geology, biology and medicine. At present, Secondary Ion Mass Spectrometry (SIMS) is in many respects the best technique to provide 3-dimensional information on the distribution of trace elements with concentrations below 1 ppm. However, due to the presence of molecular ions the detectability of many trace elements it restricted because of molecular mass interferences. In addition, detectors used in SIMS have a background counting rate of 0.1-1 Hz, which further limits trace element analysis. In Accelerator Mass Spectrometry (AMS) long-lived radionuclides are detected free of molecular interferences and detector background at isotopic ratios as low as 10 -15 . Moreover, isobaric interferences can be reduced as well. In order to benefit from these advantages a combination of SIMS and AMS (Accelerator SIMS) has been proposed almost 20 years ago, but no facility has ever been fully developed. It has been the aim of this work to add a new sputtering chamber for AMS measurements of ultrapure semiconductor material to the existing PSI/ETH AMS facility. To fulfill the requirements of material analysis, an UHV chamber with special precautions against contamination has been built and adapted to the existing AMS setup. For sputtering, a commercial Cs gun with an ExB filter and a 1 o beam bend for neutral particle suppression is used to obtain a pure Cs ion beam. The gun is equipped with different apertures for varying the diameter of the beam spot. With the integrated scanning unit the 10 keV Cs beam can be rastered over approximately 1 mm 2 . This allows different applications such as bulk analysis, depth profiling and imaging. The secondary ion extraction is matched to the ion optical and geometrical requirements of the existing accelerator mass spectrometer. (author) figs., tabs., 67 refs

  18. Determination of trace elements in seawater using Mg-scavenger as preconcentration agent, and neutron activation analysis

    International Nuclear Information System (INIS)

    Andersen, B.

    1986-01-01

    In order to determine trace elements in seawater, a preconsentration method based on coprecipitation on Mg(OH) 2 is presented. Different parameters influencing the carrying effects have been investigated using model solutions and radioactive tracers. The deposit and solution are separated by filtration. Filter with deposit is stored in quarts ampules for later determination of trace elements by means of neutron activation analysis

  19. State of the art in sample preparation for trace element analysis (M1)

    International Nuclear Information System (INIS)

    Barnes, R.M.

    2002-01-01

    Full text: The accelerated capabilities of modern trace element analysis techniques, especially inductively coupled plasma mass spectrometry (ICP-MS), have challenged the sample preparation competence of most laboratories. Exceptional analytical sensitivity, remarkable analysis speed, automated sample presentation, and intelligent sample sequencing of modern spectroscopic instrumentation have lead to demanding requirements for appropriate sample preparation steps needed for ultra trace concentration and speciation measurements. Contamination control, reliable digestion and extraction techniques, presentation of chemical forms, sample matrix management, and intelligent sample processing available today are often inadequate for the most demanding measurements. Some commercial instrumentation provides convenient implementation of well-established contamination control measures, and reagent and container purity are steadily being improved. Direct sample introduction approaches offer alternatives to conventional solution samples, but achieving calibration reliability is difficult. Developing new sample preparation chemistry is especially arduous and rare, yet progress exists in characterizing microwave-assisted reactions. This presentation will describe contemporary targets for modern sample preparation approaches for ultra trace elemental analysis and the likelihood that they can be reasonably achieved. (author)

  20. Volatile trace compounds released from municipal solid waste at the transfer stage: Evaluation of environmental impacts and odour pollution.

    Science.gov (United States)

    Zhao, Yan; Lu, Wenjing; Wang, Hongtao

    2015-12-30

    Odour pollution caused by municipal solid waste is a public concern. This study quantitatively evaluated the concentration, environmental impacts, and olfaction of volatile trace compounds released from a waste transfer station. Seventy-six compounds were detected, and ethanol presented the highest releasing rate and ratio of 14.76 kg/d and 12.30 g/t of waste, respectively. Life cycle assessment showed that trichlorofluoromethane and dichlorodifluoromethane accounted for more than 99% of impact potentials to global warming and approximately 70% to human toxicity (non-carcinogenic). The major contributor for both photochemical ozone formation and ecotoxicity was ethanol. A detection threshold method was also used to evaluate odour pollution. Five compounds including methane thiol, hydrogen sulphide, ethanol, dimethyl disulphide, and dimethyl sulphide, with dilution multiples above one, were considered the critical compounds. Methane thiol showed the highest contribution to odour pollution of more than 90%, as indicated by its low threshold. Comparison of the contributions of the compounds to different environmental aspects indicated that typical pollutants varied based on specific evaluation targets and therefore should be comprehensively considered. This study provides important information and scientific methodology to elucidate the impacts of odourant compounds to the environment and odour pollution. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Distribution of trace elements in whole blood of Syrian lymphomas patients using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Bakir, M. A.; Serhil, A.; Mohammad, A.; Habil, K.

    2013-12-01

    In recent years, there had been much interest in the concentrations of trace metals occurring in human and animal tissues and in the manner in which these concentrations may alter in malignant and other diseases. Neutron activation analysis is consider one of several methods that have been described for the determination of trace elements in biological materials. This method possesses the sensitivity and specificity necessary for the estimation at the concentrations existing naturally in most tissues, particularly when only small samples are available for analysis. The purpose of this study was to compare blood concentrations of trace elements Co, Cr, Fe, Rb, Sc, Se, Th, and Zn of lymphomas Syrian patients with those of healthy volunteers. Also, determine the relationships between trace elements concentration and the histological type of lymphomas. The blood samples were collected from 39 healthy volunteers and 49 patients with histologically confirmed lymphomas (29 Hodgkin's HL and 20 non-Hodgkin's lymphomas NHL), and analyzed to obtain the concentration of the trace elements in blood. Then, comparison between the healthy volunteers and lymphomas patients (both HL and NHL) was made to elucidate differences of the concentration distributions of the elements in blood. However, statistical analysis using Student's t test revealed significantly high concentrations of Co, Cr, Sc, and Th in lymphoma patients. Whereas Fe and Rb were found significantly decreased in lymphomas patient comparing to control group. Increasing or decreasing concentrations of Se and Zn in lymphoma patients was found not significant. Comparison between the healthy volunteers and non-Hodgkin's lymphomas patients reveled that Co, Cr, Sc, and Th were significantly elevated whereas, Rb only one trace element was decreased and all change in concentrations (elevating or decreasing) of Se and Zn were not significant. Comparison between the healthy volunteers and Hodgkin

  2. Resonance ionization and time-of-flight mass spectrometry for the analysis of trace substances in complex gas mixtures

    International Nuclear Information System (INIS)

    Nagel, Holger; Weickhardt, Christian; Boesl, Ulrich; Frey, Ruediger

    1995-01-01

    The analysis of mixtures of technical gases still comprises a lot of problems: the large number of components with very different and often rapidly varying concentrations makes great demands on analytical methods. By use of conventional analytical methods, signals of trace substances may interfere with signals of main components, whereas small signals representing low concentrations are covered by signals of main substances.The resonant-enhanced multiphoton ionization (REMPI) makes use of excited intermediate states of molecules. As these states are characteristic of each substance, one or more components of interest can be ionized with high efficiency without interference of other molecules by using a special laser-wavelength. The combination of the above mentioned ionization method with a reflectron time-of-flight mass spectrometer permits a very fast and sensitive detection of preselected trace substances.As ionization processes of higher order strongly depend on the laser intensity, there is no direct relation between ion signals and concentrations of exhaust components. Quantitative assessments are based on an especially developed calibration technique that makes use of internal standards. Applied under environmental aspects, this new analytical method helps to analyze a large number of components extracted from exhaust gases of combustion engines with high time resolution (<20 ms motor synchronously), high sensitivity (1 ppm) and high quantitative accuracy (more than 10%). A preliminary list of detectable compounds contains 30 substances

  3. Speciation analysis of 129I and its applications in environmental research

    DEFF Research Database (Denmark)

    Zhang, Luyuan; Hou, Xiaolin

    2013-01-01

    129I, a long-lived radionuclide, is important in view of geological repository of nuclear waste, and environmental tracing applications related to diverse natural processes of iodine. The environmental behaviors and bioavailability of 129I are highly related to its species. A number of methods have...... been reported for speciation analysis of 129I in a variety of environmental samples. These methods have been applied in many researches, including conversion processes of iodine species in marine and terrestrial systems, migration and retention of iodine in soil and sediment, geochemical cycling...

  4. Soil, climate and the environment - an indissociable threesome. Soil carbon and global changes: reciprocal impacts; Carbon in all its forms; Echomicadas, a new tool to analyse carbon 14; Biotransformation of metallic trace elements by soil micro-organisms; Absorption and distribution of metallic elements in plants; Dynamics of metallic contaminants in agricultural systems; Is photo-remediation for tomorrow? Hyper-accumulator plants; Sediments, tell me the Seine history... The complex history of plant feeding by the soil; The environmental analysis

    International Nuclear Information System (INIS)

    Hatte, Christine; Tisnerat-Laborde, Nadine; Ayrault, Sophie; Balesdent, Jerome; Chapon, Virginie; Bourguignon, Jacques; Alban, Claude; Ravanel, Stephane; Denaix, Laurence; Nguyen, Christophe; Vavasseur, Alain; Sarrobert, Catherine; Gasperi, Johnny; Latrille, Christelle; Savoye, Sebastien; Augusto, Laurent; Conan Labbe, Annie; Bernard Michel, Bruno; Douysset, Guilhem; Toqnelli, Antoine; Vailhen, Dominique; Moulin, Christophe

    2016-01-01

    The articles of this file on the relationships between soils, climate and the environment discuss the reciprocal impacts of soil carbon and global changes with the objective of reduction of greenhouse effect and of increase of carbon sequestration; the various forms of carbon are presented and their properties commented ; a compact radiocarbon system (ECHoMiCADAS) is presented, developed by the Laboratory of sciences of climate and environment (LSCE) and designed for the analysis of carbon 14; an article describes how micro-organisms can play a crucial role in the transformation of soil pollutants by modifying their chemical speciation and thus their toxicity; strategies based on the absorption of metallic trace elements present in the soil to control physiological processes in plants are discussed, with applications to agriculture, food supply and to the environment; researches related to the study of effects of metallic contaminants in agricultural systems are evoked, and the reasons for a slow development of phyto-technologies, notably phyto-remediation, for pollution control and decontamination of soils and liquid media, are explained. Other themes are presented : hyper-accumulator plants which present very high contents of non-essential (As, Cd, Hg, Pb, Se) or essential (Co, Cu, Fe, Mn, Mo, Ni) elements, are slowly growing, and display a limited biomass, but could be used for a phyto-extraction of metals from contaminated soils; how analysis and dating of sediments can reveal the presence of contaminants, and therefore give an insight into human activities and regulations, and into their impact on the river; how plants are able to develop strategies in their search for nutrients in different types of soils, even poor ones, and presentation of the various disciplines, methods and techniques used for environmental analysis with their applications to installation and site control, or to the study of pollutant migration

  5. Environmentally based Cost-Benefit Analysis

    International Nuclear Information System (INIS)

    Magnell, M.

    1993-11-01

    The fundamentals of the basic elements of a new comprehensive economic assessment, MILA, developed in Sweden with inspiration from the Total Cost Assessment-model are presented. The core of the MILA approach is an expanded cost and benefit inventory. But MILA also includes a complementary addition of an internal waste stream analysis, a tool for evaluation of environmental conflicts in monetary terms, an extended time horizon and direct allocation of costs and revenues to products and processes. However, MILA does not ensure profitability for environmentally sound projects. Essentially, MILA is an approach of refining investment and profitability analysis of a project, investment or product. 109 refs., 38 figs

  6. Establishment of a clean chemistry laboratory at JAERI. Clean laboratory for environmental analysis and research (CLEAR)

    Energy Technology Data Exchange (ETDEWEB)

    Hanzawa, Yukiko; Magara, Masaaki; Watanabe, Kazuo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; and others

    2003-02-01

    The JAERI has established a facility with a cleanroom: the Clean Laboratory for Environmental Analysis and Research (CLEAR). This report is an overview of the design, construction and performance evaluation of the CLEAR in the initial stage of the laboratory operation in June 2001. The CLEAR is a facility to be used for analyses of ultra trace amounts of nuclear materials in environmental samples for the safeguards, for the CTBT verification and for researches on environmental sciences. One of the special features of the CLEAR is that it meets double requirements of a cleanroom and for handling of nuclear materials. As another feature of the CLEAR, much attention was paid to the construction materials of the cleanroom for trace analysis of metal elements using considerable amounts of corrosive acids. The air conditioning and purification system, specially designed experimental equipment to provide clean work surfaces, utilities and safety systems are also demonstrated. The potential contamination from the completed cleanroom atmosphere during the analytical procedure was evaluated. It can be concluded that the CLEAR has provided a suitable condition for reliable analysis of ultra trace amounts of nuclear materials and other heavy elements in environmental samples. (author)

  7. Experimental and molecular docking investigation on metal-organic framework MIL-101(Cr) as a sorbent for vortex assisted dispersive micro-solid-phase extraction of trace 5-nitroimidazole residues in environmental water samples prior to UPLC-MS/MS analysis.

    Science.gov (United States)

    Lu, Nan; Wang, Ting; Zhao, Pan; Zhang, Lianjun; Lun, Xiaowen; Zhang, Xueli; Hou, Xiaohong

    2016-11-01

    In the presented work, metal-organic framework (MOF) material MIL-101(Cr) (MIL, Matérial Institute Lavoisier) was used as a sorbent for vortex assisted dispersive micro-solid-phase extraction (VA-D-μ-SPE) of trace amount of metronidazole (MNZ), ronidazole (RNZ), secnidazole (SNZ), dimetridazole (DMZ), tinidazole (TNZ), and ornidazole (ONZ) in different environmental water samples. Ultra-high-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) was used to quantify the target analytes. The extraction conditions, including type of sorbents, amount of MIL-101(Cr), solution pH, extraction method, extraction time, effect of salt, and elution conditions were investigated. Upon the optimal conditions, the developed method showed an excellent extraction performance with the average recovery ranging from 75.2 to 98.8 %. Good sensitivity levels were achieved with the detection limits of 0.03∼0.06 μg/L and the quantitation limits of 0.09∼0.20 μg/L. The linear ranges were varied from 0.1 to 20 for SNZ and ONZ and from 0.2 to 40 μg/L for MNZ, RNZ, DMZ, and TNZ (r 2  > 0.992), and repeatability of the method was satisfactory with the relative standard deviations (RSD) extraction and determination of 5-nitroimidazoles (5-NDZs) in 12 real water samples, showing the positive findings of MNZ and TNZ ranging from 0.3 to 1.0 μg/L. Furthermore, molecular docking was applied to explain the molecular interactions and free binding energies between MIL-101(Cr) and 5-NDZs, providing a deep insight into the adsorption mechanism. The proposed method exhibited the advantages of simplicity, rapidly, less solvent consumption, ease of operation, higher sensitivity, and lower matrix effect. Graphical abstract Schematic diagram of the extraction process and molecular docking investigation.

  8. Trace determinations of individual organic pollutants - 25 years of research at the Swiss Federal Institute for Environmental Science and Technology (EAWAG)

    Energy Technology Data Exchange (ETDEWEB)

    Giger, W. [Swiss Federal Inst. for Environmental Science and Technology (EAWAG), Duebendorf (Switzerland)

    1997-12-01

    An overview is given on analytical developments and applications for the determination of organic trace pollutants which have been performed at EAWAG since 1972. Gas and liquid chromatographic methods are of crucial importance. The presented examples include environmental hydrocarbons, semivolatile compounds and detergent-derived chemicals. (author) 4 figs., 1 tab., 6 refs.

  9. Trace-Element Analysis by Use of PIXE Technique on Agricultural Products

    Science.gov (United States)

    Takagi, A.; Yokoyama, R.; Makisaka, K.; Kisamori, K.; Kuwada, Y.; Nishimura, D.; Matsumiya, R.; Fujita, Y.; Mihara, M.; Matsuta, K.; Fukuda, M.

    2009-10-01

    In order to examine whether a trace-element analysis by PIXE (Particle Induced X-ray Emission) gives a clue to identify production area of agricultural products, we carried out a study on soy beans as an example. In the present study, a proton beam at the energy of 2.3MeV was provided by Van de Graaff accelerator at Osaka University. We used a Ge detector with Be window to measure X-ray spectra. We prepared sample soy beans from China, Thailand, Taiwan, and 7 different areas in Japan. As a result of PIXE analysis, 5 elements, potassium, iron, zinc, arsenic and rubidium, have been identified. There are clear differences in relative amount of trace-elements between samples from different international regions. Chinese beans contain much more Rb than the others, while there are significant differences in Fe and Zn between beans of Thailand and Taiwan. There are relatively smaller differences among Japanese beans. This result shows that trace-elements bring us some practical information of the region where the product grown.

  10. New method for mass spectrometric trace analysis of metals in biology and medicine

    International Nuclear Information System (INIS)

    Schulten, H.R.; Bahr, U.; Palavinskas, R.

    1984-01-01

    A first survey on the basic aspects and applications of a novel method for trace analyses of metals is given. The advantages of this methodology for analyses of trace metals which was developed by our group are: small sample amount, high sensitivity and selectivity, simple sample preparation for the measurement (no ashing) and reliability and precision of the results. The time consumption for one complete quantitative analysis lies below 30 min. The concentration of monoisotopic metals, as for example aluminium, cesium, manganese etc. is determined using a calibration curve. Using stable isotope dilution analysis quantification of metals with at least two stable isotopes further improved the precision of the results. If this technique is utilized, on one hand contamination of the environment by radioactive substances is avoided, on the other even the smallest changes in concentrations of trace metals are detected unambigeously. The accuracy of the resulting quantitative data has been confirmed test measurements with other analytical methods such as atomic absorption spectroscopy and thermal ionization mass spectrometry. Although there is no doubt that the greatest analytical capacity of field desorption mass spectrometry is in the field of high-molecular weight natural products, it has been possible in the last years to modify the method for qualitative and quantitative investigations of more than 60 metals. (orig./EF) [de

  11. Method to determine trace elements in water samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Kueppers, G.; Erdtmann, G.

    1981-05-01

    For the determination of trace elements in water by neutron activation analysis irradiation porcedures and chemical separation procedures have been developed. Irradiation in melted quarz glass ampoules in the presence of a platinum wire (for recombination of the oxyhydrogen gas produced by radiolysis) proved successfull with different variants of the irradiation methods, as long irradiation periods without pressure build-up could be achieved. Possible falsifications of the analysis results were investigated in detail (losses by absorption on vessel walls etc.). The irradiated samples can be measured directly with a gamma ray spectrometer and from the radionuclides found the trace element contents may be calculated. More sensitive determinations are possible if the radionuclides are chemically separated. Procedures for removing the matrix activities, for the separation of the radionuclides in groups of elements and for the isolation of single elements have been developed. For especially sensitive determination of some elements selective separation procedures for antimony, cadmium, selenium, mercury and uranium have been developed. The analytical procedures described have been applied to trace element determinations in river water, glacier ice and water solutions from technical processes. (orig./RB) [de

  12. Metal and trace element sediment assessment from Ribeira do Iguape river, Sao Paulo state, Brazil, by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Francisco J.V. de; Quinaglia, Gilson A., E-mail: franciscovc@cetesbnet.sp.gov.br, E-mail: gilsonn@cetesbnet.sp.gov.br [CETESB - Companhia Ambiental do Estado de Sao Paulo, SP (Brazil). ELTA - Setor de Analises Toxicologicas; Favaro, Deborah I.T., E-mail: defavaro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (LAN/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Laboratorio de Analise por Ativacao Neutronica; Franklin, Robson L.; Ferreira, Francisco J., E-mail: robsonf@cetesbnet.sp.gov.br, E-mail: franciscoj@cetesbnet.sp.gov.br [CETESB - Companhia Ambiental do Estado de Sao Paulo, SP (Brazil). ELAI - Setor de Quimica Inorganica

    2011-07-01

    The watershed region of the Ribeira do Iguape River and the estuarine complex of the Paranagua-Iguape- Cananeia and the various river basins located between this region and the Atlantic Ocean, is known as the Ribeira Valley. The Ribeira do Iguape River runs a total length of approximately 470 km, being the main source of fresh water in the Estuarine Complex of the Iguape-Cananeia-Paranagua (Lagamar). The Ribeira do Iguape River is the last major river in the State of Sao Paulo that has not been altered by dams. During virtually the entire 20th century, the region of the Ribeira Valley was the scene of constant environmental degradation resulting from the intense exploration and refining of lead, zinc and silver ores that were processed in the mines of the region, in a rudimentary way and without any control over environmental impacts. Since 1996, all such activities ceased, however, leaving behind a huge amount of environmental liabilities. This study aims to investigate the presence and concentration levels of metals and semi-metals arsenic (As), cadmium (Cd) and lead (Pb) in the sediment and water of aquatic systems of Ribeira do Iguape River and its tributaries, for an environmental assessment and monitoring of the region. The determination of these elements was carried out by GF AAS technique for water samples and ICP OES for the sediment samples. This study also assessed the occurrence of some major (Ca, Fe, K and Na), trace (As, Ba, Br, Co, Cs, Hf, Rb, Sb, Sc, Se, Ta, Th, U, Zn) and rare earth elements (La, Ce, Eu, Nd, Sm, Lu, Tb and Yb) by Neutron Activation Analysis (NAA). Validation of both methodologies, according to precision and accuracy, was done by reference material analyses. The results obtained for As, Cd and Pb were compared to the Canadian Environmental oriented values (TEL and PEL). The results obtained for multielemental analyses in the sediment samples were compared to UCC values (Upper Continental Crust). (author)

  13. Metal and trace element sediment assessment from Ribeira do Iguape river, Sao Paulo state, Brazil, by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Castro, Francisco J.V. de; Quinaglia, Gilson A.; Favaro, Deborah I.T.; Franklin, Robson L.; Ferreira, Francisco J.

    2011-01-01

    The watershed region of the Ribeira do Iguape River and the estuarine complex of the Paranagua-Iguape- Cananeia and the various river basins located between this region and the Atlantic Ocean, is known as the Ribeira Valley. The Ribeira do Iguape River runs a total length of approximately 470 km, being the main source of fresh water in the Estuarine Complex of the Iguape-Cananeia-Paranagua (Lagamar). The Ribeira do Iguape River is the last major river in the State of Sao Paulo that has not been altered by dams. During virtually the entire 20th century, the region of the Ribeira Valley was the scene of constant environmental degradation resulting from the intense exploration and refining of lead, zinc and silver ores that were processed in the mines of the region, in a rudimentary way and without any control over environmental impacts. Since 1996, all such activities ceased, however, leaving behind a huge amount of environmental liabilities. This study aims to investigate the presence and concentration levels of metals and semi-metals arsenic (As), cadmium (Cd) and lead (Pb) in the sediment and water of aquatic systems of Ribeira do Iguape River and its tributaries, for an environmental assessment and monitoring of the region. The determination of these elements was carried out by GF AAS technique for water samples and ICP OES for the sediment samples. This study also assessed the occurrence of some major (Ca, Fe, K and Na), trace (As, Ba, Br, Co, Cs, Hf, Rb, Sb, Sc, Se, Ta, Th, U, Zn) and rare earth elements (La, Ce, Eu, Nd, Sm, Lu, Tb and Yb) by Neutron Activation Analysis (NAA). Validation of both methodologies, according to precision and accuracy, was done by reference material analyses. The results obtained for As, Cd and Pb were compared to the Canadian Environmental oriented values (TEL and PEL). The results obtained for multielemental analyses in the sediment samples were compared to UCC values (Upper Continental Crust). (author)

  14. Trace analysis of irradiated steel samples from hiroshima by laser ablation inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Helal, A.I.; Zahran, N.F.

    2000-01-01

    A double focusing (JEOL, PLASMAX2) and quadrupole (ELAN6000, Perkin Elmer) mass spectrometers were used for the quantitative analysis of trace elements in steel samples from Hiroshima. The quantification of the analytical results was carried out using steel 468 as a standard reference material. The relative sensitivity coefficients (RSC's) for most of the elements varied between 0.12 and 2.93. The effect of iron as a matrix and the non-spectroscopic interferences are studied. Comparison of the results obtained on two steel samples from Hiroshima with that obtained on steel 468 standard reference materials demonstrated that there is no significant difference between them. Therefore, it is possible to say that the irradiated steel samples from Hiroshima have nearly the same specifications of trace element content as those of the normal steel samples

  15. Vertical distribution of particulate trace elements in a street canyon determined by PIXE analysis

    International Nuclear Information System (INIS)

    Raunemaa, T.; Hautojaervi, A.; Kaisla, K.; Gerlander, M.

    1981-01-01

    Suspended particles in a street canyon were investigated by collecting air particulate matter on thin filters at heigths 2.3 to 20.5 m. The weather parameters and traffic characteristics were registered during the collection. Quantitative analysis of 15 trace elements from AI to Pb was carried out by the PIXE method using 1.8-2.0 MeV protons. The concentration of lead was found to decrease exponentially when going from street level to roof level. Almost all the trace elements analyzed were found to fall into two groups with different vertical distributions. The collected matter above 10 m height was found to be due mainly to combustion originated motor vehicle exhaust, the matter below 10 m to soil originated dust. (orig.)

  16. Trace elements in Turkish tobacco determined by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Gulovali, M.C.

    1977-01-01

    This study was undertaken to determine the concentration of trace elements in nine different brands of Turkish cigarette tobacco, pipe tobacco and tobacco ash. Instrumental neutron activation analysis was employed, and a gamma-ray spectrometer consisting of 40 cm 3 Ge(Li) detector coupled to 1024 and 4096-channel analyzers were used. Samples were irradiated at a thermal neutron flux of about 10 13 cm -2 sec -1 . Concentrations of Na, K, Sc, Cr, Fe, Co, Zn, As, Se, Br, Rb, Sb, Cs, Ba, La, Ce, Eu, Hf, Hg and Th were determined in tobacco and ash; percent transference of these elements into ash were calculated. It was found out that trace elements in cigarette tobacco are left in the ash but only a small percentage is transferred into the smoke

  17. Analytical analysis of soil-moisture and trace-contaminant transport

    International Nuclear Information System (INIS)

    Larson, N.M.; Reeves, M.

    1976-03-01

    A transport model is presented which predicts the coupled movement of both water and trace contaminants through a layered and unsaturated soil-moisture zone. In order to achieve computation speeds suitable for watershed implementations, moisture properties are approximated as exponential functions of pressure head, and lateral flows are treated as sinks in a basically vertical one-dimensional analysis. In addition, only advection by the Darcy-flow velocities and linear adsorption by the soil matrix are considered in depicting movement of the trace contaminant. Formal solution of the resulting transport equations is obtained through use of both eigenfunction-expansion and coordinate-transformation methods. Numerical solution is effected by means of a program written in FORTRAN IV and implemented on an IBM 360/91 computer. Two example calculations illustrate both strengths and weaknesses of our model

  18. Problems of accuracy and sources of error in trace analysis of elements

    International Nuclear Information System (INIS)

    Porat, Ze'ev.

    1995-07-01

    The technological developments in the field of analytical chemistry in recent years facilitates trace analysis of materials in sub-ppb levels. This provides important information regarding the presence of various trace elements in the human body, in drinking water and in the environment. However, it also exposes the measurements to more severe problems of contamination and inaccuracy due to the high sensitivity of the analytical methods. The sources of error are numerous and can be included in three main groups: (a) impurities of various sources; (b) loss of material during sample processing; (c) problems of calibration and interference. These difficulties are discussed here in detail, together with some practical solutions and examples.(authors) 8 figs., 2 tabs., 18 refs.,

  19. Radiochemical neutron activation analysis for trace elements of basic ingredients of pan

    International Nuclear Information System (INIS)

    Zaidi, J.H.; Arif, M.; Fatima, I; Qureshi, I.H.

    2002-01-01

    Extensive use of pan, by one-tenth of world's population, entails the evaluation of trace element contents in its ingredients. Radiochemical neutron activation analysis (RNAA) was developed and successfully employed to determine the concentration of 36 trace elements (essential, toxic and nonessential) in its four basic ingredients, leaf of betel pepper, betel nut, catechu and lime. The radiochemical separation methodology has significantly improved the detection limits of most of these elements due to suppression of Compton background. Base-line values of certain toxic and essential elements in these ingredients is provided. The daily intake of essential and toxic elements through pan was estimated and compared with the recommended values. The cumulative intake of Mn is four times higher than the recommended value and that of toxic elements is well below the tolerance limits. (author)

  20. Problems of accuracy and sources of error in trace analysis of elements

    Energy Technology Data Exchange (ETDEWEB)

    Porat, Ze` ev

    1995-07-01

    The technological developments in the field of analytical chemistry in recent years facilitates trace analysis of materials in sub-ppb levels. This provides important information regarding the presence of various trace elements in the human body, in drinking water and in the environment. However, it also exposes the measurements to more severe problems of contamination and inaccuracy due to the high sensitivity of the analytical methods. The sources of error are numerous and can be included in three main groups: (a) impurities of various sources; (b) loss of material during sample processing; (c) problems of calibration and interference. These difficulties are discussed here in detail, together with some practical solutions and examples.(authors) 8 figs., 2 tabs., 18 refs.,.

  1. Determination of trace elements by neutron activation analysis using dinonylnaphtalene sulfonic acid as a preconcentrating agent

    International Nuclear Information System (INIS)

    Yang, M.H.; Chen, P.Y.; Tseng, C.L.; Yeh, S.J.; Weng, P.S.

    1977-01-01

    Dinonylnaphthalene sulfonic acid (HD) has been used as a preconcentrating agent to enrich trace metal ions and to separate the interfering elements such as Na, K, Cl and Br, which normally exist in the natural aqueous systems. Experiments were performed by extracting the ions in the aqueous medium with HD in n-hexane and subsequently backextracted into a minimal volume of acid solution. Factors influencing the extraction efficiency of the ions of interest were investigated. The preconcentration technique has been successfully applied to the determination by neutron activation analysis of trace elements in natural water and biological materials. Both short-lived nuclides (Mg, Al, Ca, Mn) and long-lived nuclides (Sm, Eu, Zn, La, Cr, Sc, Fe, Co) in the ppb-level concentrations were determined. (T.G.)

  2. Conditional Probability Analysis: A Statistical Tool for Environmental Analysis.

    Science.gov (United States)

    The use and application of environmental conditional probability analysis (CPA) is relatively recent. The first presentation using CPA was made in 2002 at the New England Association of Environmental Biologists Annual Meeting in Newport. Rhode Island. CPA has been used since the...

  3. Survey of currently available reference materials for use in connection with the determination of trace elements in biological and environmental materials

    International Nuclear Information System (INIS)

    Muramatsu, Y.; Parr, R.M.

    1985-12-01

    This report focuses on analytical reference materials which have been developed for use in connection with the determination of toxic and essential trace elements in biomedical and health-related environmental samples. Data are reported on 60 biological and 40 environmental (non-biological) reference materials from 11 suppliers. Certified concentration values (or their equivalents) and non-certified concentration values (or information values) are presented in various tables which are intended to help the user select a reference material that matches as closely as possible (i.e. with respect to matrix type and concentration of the element of interest) the ''real'' samples that are to be analysed. These tables have been generated from a database characterized by the following parameters: total number of reference materials=100; total number of elements recorded=69; total number of concentration values recorded=1771. Also included in the report is information (where available) on the cost of each material, the unit weight or volume supplied, and the minimum weight of material recommended for analysis. (author)

  4. Significant improvement of accuracy and precision in the determination of trace rare earths by fluorescence analysis

    International Nuclear Information System (INIS)

    Ozawa, L.; Hersh, H.N.

    1976-01-01

    Most of the rare earths in yttrium, gadolinium and lanthanum oxides emit characteristic fluorescent line spectra under irradiation with photons, electrons and x rays. The sensitivity and selectivity of the rare earth fluorescences are high enough to determine the trace amounts (0.01 to 100 ppM) of rare earths. The absolute fluorescent intensities of solids, however, are markedly affected by the synthesis procedure, level of contamination and crystal perfection, resulting in poor accuracy and low precision for the method (larger than 50 percent error). Special care in preparation of the samples is required to obtain good accuracy and precision. It is found that the accuracy and precision for the determination of trace (less than 10 ppM) rare earths by fluorescence analysis improved significantly, while still maintaining the sensitivity, when the determination is made by comparing the ratio of the fluorescent intensities of the trace rare earths to that of a deliberately added rare earth as reference. The variation in the absolute fluorescent intensity remains, but is compensated for by measuring the fluorescent line intensity ratio. Consequently, the determination of trace rare earths (with less than 3 percent error) is easily made by a photoluminescence technique in which the rare earths are excited directly by photons. Accuracy is still maintained when the absolute fluorescent intensity is reduced by 50 percent through contamination by Ni, Fe, Mn or Pb (about 100 ppM). Determination accuracy is also improved for fluorescence analysis by electron excitation and x-ray excitation. For some rare earths, however, accuracy by these techniques is reduced because indirect excitation mechanisms are involved. The excitation mechanisms and the interferences between rare earths are also reported

  5. Enhancing effect of marine oligotrophy on environmental concentrations of particle-reactive trace elements

    International Nuclear Information System (INIS)

    Jeffree, R.A.; Szymczak, R.

    2000-01-01

    A biogeochemical model has been previously developed that explains the inverse and nonlinear relationship between Po-210 concentration in zooplankton and their biomass, under oligotrophic conditions in French Polynesia. In this study the model structure was reviewed to determine a set of biogeochemical behaviors of Po-210, proposed to be critical to its environmental enhancement under oligotrophy: this set was then used to identify 25 other elements with comparable behaviors to Po-210. Field investigation in the Timor Sea showed that four of these a priori identified elements, viz. Cd, Co, Pb, and Mn as well as Cr and Ni, showed elevated water concentrations with reduced particle removal rates in the euphotic zone, results that are consistent with those previously obtained for Po-210 and the proposed explanatory model. These findings point to the enhanced susceptibility to contamination with particle-reactive elements of oligotrophic marine systems, whose degree and geographic extent may be enhanced by projected increases in sea surface temperatures from global warming

  6. Trace element determination in soft tissues of marine bivalves by activation analysis

    International Nuclear Information System (INIS)

    Fukushima, M.; Tamate, H.; Nakano, Y.

    2003-01-01

    Trace elements in soft tissues of marine bivalves were determined by neutron activation analysis (NAA) and photon activation analysis (PAA). Elemental levels of Ag, As, Br, Co, Cu, Fe, I, Mn, Ni, Rb, Se, and Zn in the organs of giant ezoscallos, rock oysters, and giant crams were obtained. The metal-bound proteins were extracted from the mantles and hepatopancreases of rock oysters. By irradiating the fraction obtained by HPLC gel chromatography, the possibility for the existence of an Ag bound protein in the mantles was found. (author)

  7. Microcalorimeter Q-spectroscopy for rapid isotopic analysis of trace actinide samples

    Energy Technology Data Exchange (ETDEWEB)

    Croce, M.P., E-mail: mpcroce@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM (United States); Bond, E.M.; Hoover, A.S.; Kunde, G.J.; Mocko, V.; Rabin, M.W.; Weisse-Bernstein, N.R.; Wolfsberg, L.E. [Los Alamos National Laboratory, Los Alamos, NM (United States); Bennett, D.A.; Hays-Wehle, J.; Schmidt, D.R.; Ullom, J.N. [National Institute of Standards and Technology, Boulder, CO (United States)

    2015-06-01

    We are developing superconducting transition-edge sensor (TES) microcalorimeters that are optimized for rapid isotopic analysis of trace actinide samples by Q-spectroscopy. By designing mechanically robust TESs and simplified detector assembly methods, we have developed a detector for Q-spectroscopy of actinides that can be assembled in minutes. We have characterized the effects of each simplification and present the results. Finally, we show results of isotopic analysis of plutonium samples with Q-spectroscopy detectors and compare the results to mass spectrometry.

  8. Sampling and sample preparation methods for the analysis of trace elements in biological material

    International Nuclear Information System (INIS)

    Sansoni, B.; Iyengar, V.

    1978-05-01

    The authors attempt to give a most systamtic possible treatment of the sample taking and sample preparation of biological material (particularly in human medicine) for trace analysis (e.g. neutron activation analysis, atomic absorption spectrometry). Contamination and loss problems are discussed as well as the manifold problems of the different consistency of solid and liquid biological materials, as well as the stabilization of the sample material. The process of dry and wet ashing is particularly dealt with, where new methods are also described. (RB) [de

  9. Retention of 32P activity interfering with the neutron activation analysis of trace elements in biosamples

    International Nuclear Information System (INIS)

    Sziklai-Laszlo, I.; Ordogh, M.

    1978-06-01

    Experiments were performed to eliminate the disturbing effect of 32 P when neutron activation analysis is used for the trace element analysis of biological materials. For this reason amorphous zirconium phosphate was selected and prepared by the authors. Retention factors better than 10 2 were obtained using conventional batch techniques. The retention of Cr, Sb, Sc, Zn, Rb, Co and Fe were investigated in nitric acid media, and it was found to be less than 5%. Bowen's kale, dry potato powder and animal bone were analyzed. Some numerical results are given and gamma spectra are shown. (T.G.)

  10. Microcalorimeter Q-spectroscopy for rapid isotopic analysis of trace actinide samples

    International Nuclear Information System (INIS)

    Croce, M.P.; Bond, E.M.; Hoover, A.S.; Kunde, G.J.; Mocko, V.; Rabin, M.W.; Weisse-Bernstein, N.R.; Wolfsberg, L.E.; Bennett, D.A.; Hays-Wehle, J.; Schmidt, D.R.; Ullom, J.N.

    2015-01-01

    We are developing superconducting transition-edge sensor (TES) microcalorimeters that are optimized for rapid isotopic analysis of trace actinide samples by Q-spectroscopy. By designing mechanically robust TESs and simplified detector assembly methods, we have developed a detector for Q-spectroscopy of actinides that can be assembled in minutes. We have characterized the effects of each simplification and present the results. Finally, we show results of isotopic analysis of plutonium samples with Q-spectroscopy detectors and compare the results to mass spectrometry

  11. Analysis and characterization of trace elements in shale oil and shale oil products by instrumental neutron activation analysis. Master's thesis

    International Nuclear Information System (INIS)

    Shaw, P.

    1978-12-01

    Trace elements and their mobilization constitute an important consideration in the development of new fossil fuel technologies. Shale oil produced by in situ retorting of oil shale is an alternative fossil energy source. This study deals with the analysis of trace elements in various shale oil products using instrumental neutron activation analysis (INAA). INAA offers several advantages for those elements for which it is applicable. The greatest advantage is the lack of sample preparation prior to analysis, which greatly simplifies the process and prevents sample contamination. The elements for which analyses are reported in this study are aluminum, antimony, arsenic, bromine, cerium, chlorine, chromium, cobalt, copper, gallium, gold, iodine, iron, manganese, mercury, molybdenum, potassium, selenium, sodium, sulfur, tungsten, vanadium, and zinc

  12. Uncertainties in measuring trace amounts of cobalt and europium with low-flux neutron activation analysis

    Directory of Open Access Journals (Sweden)

    Burnham Steven

    2017-01-01

    Full Text Available Neutron activation analysis is widely used for identification of elements and their quantities even in trace amounts in the samples of almost any type. The challenges in detecting trace amounts of particular elements are often associated with the neutron flux produced at the research reactors. Low-flux neutron activation analysis usually presents the biggest challenge when analyzing trace quantities of elements with lower magnitude of radiative capture cross-sections. In this paper, we present the methodology and the quantified uncertainties associated with the detection of trace amounts of cobalt and europium, using as an example concrete aggregates. Recent growing interest is in improving structural concrete (increasing its strength but reducing its activation in nuclear power plant environments. Aside from buildings, structural concrete is also used as a biological shield in nuclear power plant that become radioactive after exposure to neutron flux. Due to radiative capture interactions, artificial radionuclides are generated to high enough concentrations that classify concrete as low-level radioactive waste at the time of the plant's decommissioning. Disposal of this concrete adds to the expense of nuclear power plant financing and its construction. Three radionuclides, 60Co, 152Eu, and 154Eu, account for 99 % of total residual radioactivity of nuclear power plant decommissioned concrete. IAEA document RS-G-1.7, Application of the Concepts of Exclusion, Exemption, and Clearance, specifies clearance levels of radionuclides specific activities: a specific activity lower than 0.1 Bqg-1 for 60Co and 152Eu, and 154Eu allows for a concrete to be recycled after decommissioning of the nuclear power plant. Therefore, low-flux neutron activation analysis is used to test the detection limits of trace elements in samples of cement, coarse, and fine concrete aggregates. These samples are irradiated at the University of Utah's 100 kW TRIGA Reactor at

  13. Trace element analysis of human blood serum by neutron activation analysis

    International Nuclear Information System (INIS)

    Nakahara, H.; Nagame, Y.; Yoshizawa, Y.; Oda, H.; Gotoh, S.; Murakami, Y.

    1979-01-01

    An attempt was made to determine if there is any correlation between trace element concentrations in human blood serum and some specific diseases. The serum samples of the patients suffering from cancer, Down syndrome, and Banti syndrome were analyzed by the neutron activation method and compared with the trace element concentrations observed among clinically healthy men. The cancer patients had concentrations in Rb, Mn, Fe, Co, Cu, Zn, Al and Se below normal. The Down syndrome patients were found to have similar deficiencies in Cr, Mn, Fe, Co, Zn, Cu and Sb. (author)

  14. Trace Elements in Human Myocardial Infarction Determined by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Wester, P.O.

    1965-05-01

    By means of neutron activation analysis, injured and adjacent uninjured human heart tissue from 12 autopsy cases with myocardial infarction are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent y-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, Zn and W. In the injured tissue compared to the uninjured, calculation on a wet weight basis showed a decrease in Co, Cs, K, Mo, P, Rb and Zn, and an increase in Br, Ca, Ce, La, Na, Sb and Sm. The differences in Ca, La, Mo, P and Zn are dependent on the age of the myocardial infarction, and the regression lines for these elements are given. The concentration of the trace elements in uninjured tissue from infarcted hearts is compared to the concentration of these elements in normal heart tissue, determined in a previous study. In the uninjured tissue from infarcted hearts a decrease is found in Cu and Mo, and an increase in As and Ce

  15. Trace Elements in Human Myocardial Infarction Determined by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wester, P O

    1965-05-15

    By means of neutron activation analysis, injured and adjacent uninjured human heart tissue from 12 autopsy cases with myocardial infarction are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent y-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, Zn and W. In the injured tissue compared to the uninjured, calculation on a wet weight basis showed a decrease in Co, Cs, K, Mo, P, Rb and Zn, and an increase in Br, Ca, Ce, La, Na, Sb and Sm. The differences in Ca, La, Mo, P and Zn are dependent on the age of the myocardial infarction, and the regression lines for these elements are given. The concentration of the trace elements in uninjured tissue from infarcted hearts is compared to the concentration of these elements in normal heart tissue, determined in a previous study. In the uninjured tissue from infarcted hearts a decrease is found in Cu and Mo, and an increase in As and Ce.

  16. Trace analysis of loss of feedwater flow event in Lungmen ABWR

    International Nuclear Information System (INIS)

    Wang Jongrong; Lin Haotzu; Wang Weichen; Yang Shuming; Shih Chunkuan

    2009-01-01

    TRACE (TRAC/RELAP Advanced Computational Engine) model of Lungmen Nuclear Power Plant was used to analyze the Loss of Feedwater Flow transient as defined in Lungmen FSAR Chapter 15. The results were compared with those from FSAR and RETRAN02. Lungmen TRACE model will have two models: In model A, vessel is divided into 11 axial levels, 4 radial rings and 1 azimuthal sectors; In model B, vessel is divided into 11 axial levels, 4 radial rings, and 6 azimuthal sectors. The above models include feedwater control system, narrow range water level control system, and wide range water level control system. The loss of feedwater flow (LOFW) transient began with the trip of two operating feedwater pumps either from the pump mechanical/electric failure, or the operator human error, or high water level signal. Feedwater flow was assumed to descend to 0 in 5 seconds and led to the decrease of reactor water level. At L3 low water level setpoint, the system actuated reactor scram signal and RIP trip signal for RIPs not connected to the M/G set. At L2 low-low water level setpoint, the system would trip the other six RIPs. This paper compares those important thermal parameters at steady state, such as the dome pressure and temperature of reactor vessel, steam flow, feedwater flow, core flow, and RIP flow, etc.. It also compares system parameters under transient conditions, such as core thermal power, core flow, steam flow, feedwater flow, Narrow Range Water Level (NRWL), Wide Range Water Level (WRWL) and RIP flow, etc.. It was concluded that the steady state and transient results of TRACE calculations are in good agreement with those from RETRAN02. In summary, our studies concluded that Lungmen TRACE model is correct and accurate enough for future safety analysis applications. (author)

  17. PIXE analysis of trace and other mineral elements in phytopharmaceutical drugs

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Harangus, Livia; Iordan, Andreea; Gugiu, M.

    2002-01-01

    Despite of ongoing progress in the biochemistry of phytopharmaceutical drugs, their mineral micro- and trace elements have not been studied in detail. These elements may have therapeutic or toxic activity which should be assessed by sensitive investigations. The latter can be done by multielemental analysis with nuclear and atomic methods. We previously found 28 elements in some Romanian plant drugs by nuclear activation analysis. The availability of this method is, however, limited by the access to a nuclear reactor. Particle-induced X-ray emission (PIXE) is an alternative method with high performances in biomedicine and requiring no sample preparation for drugs' studies. We applied PIXE in the qualitative analysis of three plant drugs - Liv52, Mentat, and Geriforte - used as invigorators, protectors and prophylactics in oxidative stress diseases. Measurements with 3 MeV protons at the 8.5 MV NIPNE-HH (Horia Hulubei National Institute for Physics and Nuclear Engineering) tandem accelerator, using a hyper-pure Ge detector and no additional absorber foil, evidenced unusually complex elemental compositions of drugs. Up to 31 elements with Z > 15 were found: P, S, Cl, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Br, Rb, Sr, Y, Zr, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu, Hg, and As and/or Pb, from major to trace levels. The three drugs' qualitative composition were found to be rather similar. Relative concentrations were well evaluated with X-ray yields calculated for another kind of light element thick target. Drug's toxic elements - As and/or Pb, Hg, and possibly Ga - were all at trace levels, but their accumulation might be harmful. Some essential elements like K, Ca, Cr, Fe, Cu, Zn, Br, Rb, Sr can be biologically useful. X-ray yields improvement and other ways for PIXE quantitative analysis of the phytotherapeutic drugs are outlined. (authors)

  18. Proton induced X-Ray fluorescence study as a tool trace element analysis

    International Nuclear Information System (INIS)

    El-Kady, Ahmed A.

    1978-01-01

    Usefulness and limitations of trace elemental analysis by high energy charged particles and photon induced X-ray have been discussed. Comparison with the well established neutron activation analysis technique is also given. Back-ground radiation due to bremsstrahlung from secondary electrons and due to charged particle bremsstrahlung have been reviewed for different projectiles. The sensitivity of elemental analysis by proton induced X-ray fluorescence have been examined by measuring the characteristic X-ray emission cross section for K and L transitions of many elements and for different proton energies and compared with theroretical values. The discussion given in this report show that with suitable proton generator and a high resolution X-ray detector, proton X-ray fluorescence technique is capable of analyzing many elements simultaneously at the part per million level and offers a rapid and reliable method for trace element analysis. Data on water, blood and tissue samples given in this report are few examples of many possible applications

  19. Integrating health and environmental impact analysis

    DEFF Research Database (Denmark)

    Reis, S; Morris, G.; Fleming, L. E.

    2015-01-01

    which addresses human activity in all its social, economic and cultural complexity. The new approach must be integral to, and interactive, with the natural environment. We see the continuing failure to truly integrate human health and environmental impact analysis as deeply damaging, and we propose...... while equally emphasizing the health of the environment, and the growing calls for 'ecological public health' as a response to global environmental concerns now suffusing the discourse in public health. More revolution than evolution, ecological public health will demand new perspectives regarding...... the interconnections among society, the economy, the environment and our health and well-being. Success must be built on collaborations between the disparate scientific communities of the environmental sciences and public health as well as interactions with social scientists, economists and the legal profession...

  20. Sensitive trace enrichment of environmental andiandrogen vinclozolin from natural waters and sediment samples using hollow-fiber liquid-phase microextraction.

    Science.gov (United States)

    Lambropoulou, Dimitra A; Albanis, Triantafyllos A

    2004-12-17

    The presence of vinclozolin in the environment as far as the endocrine disruption effects in biota are concerned has raised interest in the environmental fate of this compound. In this respect, the present study attempts to investigate the feasibility of applying a novel quantitative method, liquid-phase microextraction (LPME), so as to determine this environmental andiandrogen in environmental samples such as water and sediment samples. The technique involved the use of a small amount (3 microL) of organic solvent impregnated in a hollow fiber membrane, which was attached to the needle of a conventional GC syringe. The extracted samples were analyzed by gas chromatography coupled with electron-capture detection. Experimental LPME conditions such as extraction solvent, stirring rate, content of NaCl and pH were tested. Once LPME was optimized, the performance of the proposed technique was evaluated for the determination of vinclozolin in different types of natural water samples. The recovery of spiked water samples was from 80 to 99%. The procedure was adequate for quantification of vinclozolin in waters at levels of 0.010 to 50 microg/L (r> 0.994) with a detection limit of 0.001 microg/L (S/N= 3). Natural sediment samples from the Aliakmonas River area (Macedonia, Greece) spiked with the target andiandrogen compound were liquid-liquid extracted and analyzed by the methodology developed in this work. No significant interferences from the samples matrix were noticed, indicating that the reported methodology is an innovative tactic for sample preparation in sediment analysis, with a considerable improvement in the achieved detection limits. The results demonstrated that apart from analyte enrichment, the proposed LPME procedure also serves as clean-up method and could be successfully performed to determine trace amounts of vinclozolin in water and sediment samples.

  1. Historical economic and environmental policies influencing trace metal inputs in Montevideo Bay, Río de la Plata.

    Science.gov (United States)

    Bueno, C; Brugnoli, E; Figueira, R C L; Muniz, P; Ferreira, P A L; García Rodríguez, F

    2016-12-15

    Montevideo Bay is located in the middle zone of the Rio de la Plata, and since the foundation of the city, several key economic and environmental policies affected the industry, and thus, metal inputs into this ecosystem. The aim of this study is to evaluate the sedimentary geochemical record of Montevideo Bay, in order to determine the historical inputs of anthropogenic metals to the system. In addition, environmental and economic policies of the country were taken into account to infer the relationship between them and the historic metal input. Concentrations of aluminum, chromium, copper, lead, scandium and zinc were analyzed and the EF and SPI indices were calculated. The analysis showed that since Montevideo foundation, metal concentrations increased in accordance with industry development, and the indices as well as the metal concentration represent a reliable footprint of the history of different economic and environmental policies influencing historical industrial activities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. TRACE analysis of Phenix core response to an increase of the core inlet sodium temperature

    Energy Technology Data Exchange (ETDEWEB)

    Chenu, A., E-mail: aurelia.chenu@psi.ch [Paul Scherrer Inst., Villigen PSI (Switzerland); Ecole Polytechnique Federale (Switzerland); Mikityuk, K., E-mail: konstantin.mikityuk@psi.ch [Paul Scherrer Inst., Villigen PSI (Switzerland); Adams, R., E-mail: robert.adams@psi.ch [Paul Scherrer Inst., Villigen PSI (Switzerland); Eidgenossische Technische Hochschule, Zurich (Switzerland); Chawla, R., E-mail: rakesh.chawla@epfl.ch [Paul Scherrer Inst., Villigen PSI (Switzerland); Ecole Polytechnique Federale (Switzerland)

    2011-07-01

    This work presents the analysis, using the TRACE code, of the Phenix core response to an inlet sodium temperature increase. The considered experiment was performed in the frame of the Phenix End-Of-Life (EOL) test program of the CEA, prior to the final shutdown of the reactor. It corresponds to a transient following a 40°C increase of the core inlet temperature, which leads to a power decrease of 60%. This work focuses on the first phase of the transient, prior to the reactor scram and pump trip. First, the thermal-hydraulic TRACE model of the core developed for the present analysis is described. The kinetic parameters and feedback coefficients for the point kinetic model were first derived from a 3D static neutronic ERANOS model developed in a former study. The calculated kinetic parameters were then optimized, before use, on the basis of the experimental reactivity in order to minimize the error on the power calculation. The different reactivity feedbacks taken into account include various expansion mechanisms that have been specifically implemented in TRACE for analysis of fast-neutron spectrum systems. The point kinetic model has been used to study the sensitivity of the core response to the different feedback effects. The comparison of the calculated results with the experimental data reveals the need to accurately calculate the reactivity feedback coefficients. This is because the reactor response is very sensitive to small reactivity changes. This study has enabled us to study the sensitivity of the power change to the different reactivity feedbacks and define the most important parameters. As such, it furthers the validation of the FAST code system, which is being used to gain a more in-depth understanding of SFR core behavior during accidental transients. (author)

  3. Evaluation of trace elements in different species of lichens by neutron activation analysis

    International Nuclear Information System (INIS)

    Coccaro, D.M.B.; Saiki, M.; Vasconcellos, M.B.A.

    2000-01-01

    Instrumental neutron activation analysis has been applied for the determination of trace elements in five epiphytic lichens: Canoparmelia texana, Canoparmelia caroliniana, Parmotrema tinctorum, Parmotrema sancti-angeli and Usnea sp. that were collected at the same sampling area of the Botanic Institute, Sao Paulo, Brazil. The elemental concentration results showed that these five lichens can be chosen in the species intercalibration for biomonitoring studies. Also, some aspects related to the occurrence, tolerance to pollution, treatment and ease of sampling of the species are presented. (author)

  4. Ar-39 Detection at the 10^-16 Isotopic Abundance Level with Atom Trap Trace Analysis

    OpenAIRE

    Jiang, W.; Williams, W. D.; Bailey, K.; Davis, A. M.; Hu, S. -M.; Lu, Z. -T.; O'Connor, T. P.; Purtschert, R.; Sturchio, N. C.; Sun, Y. R.; Mueller, P.

    2011-01-01

    Atom Trap Trace Analysis (ATTA), a laser-based atom counting method, has been applied to analyze atmospheric Ar-39 (half-life = 269 yr), a cosmogenic isotope with an isotopic abundance of 8x10^-16. In addition to the superior selectivity demonstrated in this work, counting rate and efficiency of ATTA have been improved by two orders of magnitude over prior results. Significant applications of this new analytical capability lie in radioisotope dating of ice and water samples and in the develop...

  5. Determination of trace elements in poly(methyl methacrylate) by neutron activation analysis

    International Nuclear Information System (INIS)

    Kobayashi, M.

    1979-01-01

    The results are reported of the neutron activation analysis of poly(methyl methacrylate) polymerized with a redox system of chromium (II) acetate and p-chlorobenzyl peroxide in dimethylformamide at 30 0 C. Since the polymer was originally synthesized in experiments for kinetic studies, the results indicate an arbitrary background of purity of polymers obtained in a laboratory. Samples were irradiated for 28m and gamma spectra detected trace amounts of chlorine, aluminum, vanadium, magnesium, manganese, potassium, copper, zinc, sodium, bromine, lanthanum, gold, and chromium. 2 figures, 1 table

  6. Photon activation analysis of trace metals in the livers and spleens of pigs

    International Nuclear Information System (INIS)

    Fukushima, M.

    1995-01-01

    Nondestructive photon activation analysis with 30 MeV bremsstrahlung was applied to determine trace element concentrations in the livers and spleens of five pigs. Samples were freeze-dried, pulverized and fractionated into four groups corresponding mesh size ; smaller than 60 mesh, 60-100 mesh, 100-200 mesh and larger than 200 mesh. Up to 9 elements in each fraction were analyzed. The concentrations of Br, Fe, Mg, Mn, Mo, Na, Rb and Zn in each liver fractions were almost constant, as were concentrations of Mg and Rb in spleens. (author). 10 refs., 7 tabs

  7. Application of synchrotron radiation to x-ray fluorescence analysis of trace elements

    International Nuclear Information System (INIS)

    Gordon, B.M.; Jones, K.W.; Hanson, A.L.

    1986-08-01

    The development of synchrotron radiation x-ray sources has provided the means to greatly extend the capabilities of x-ray fluorescence analysis for determinations of trace element concentrations. A brief description of synchrotron radiation properties provides a background for a discussion of the improved detection limits compared to existing x-ray fluorescence techniques. Calculated detection limits for x-ray microprobes with micrometer spatial resolutions are described and compared with experimental results beginning to appear from a number of laboratories. The current activities and future plans for a dedicated x-ray microprobe beam line at the National Synchrotron Light Source (NSLS) of Brookhaven National Laboratory are presented

  8. Determination of trace elements in human brain tissues using neutron activation analysis

    International Nuclear Information System (INIS)

    Leite, R.E.P.; Jacob-Filho, W.; Grinberg, L.T.; Ferretti, R.E.L.

    2008-01-01

    Neutron activation analysis was applied to assess trace element concentrations in brain tissues from normal (n = 21) and demented individuals (n = 21) of both genders aged more than 50 years. Concentrations of the elements Br, Fe, K, Na, Rb, Se and Zn were determined. Comparisons were made between the results obtained for the hippocampus and frontal cortex tissues, as well as, those obtained in brains of normal and demented individuals. Certified reference materials, NIST 1566b Oyster Tissue and NIST 1577b Bovine Liver were analyzed for quality of the analytical results. (author)

  9. Trace elements in cigarette tobacco by a method of instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Noordin Ibrahim

    1986-01-01

    A total of ten cigarette brands were investigated for determining the trace elemental concentrations in tobacco so as to assess their role in the induction of related diseases through smoking. A method instrumental Neutron Activation analysis was employed due to high sensitivity, speed and ability to analyse sample for a wide spectrum of elements simultaneously. A total of 18 elements were detected of which the majority are toxic elements. A full result and conclusion will be reported in the forthcoming paper. (A.J.)

  10. Neutron activation analysis of trace metals in the livers of Japanese sika deer (cervus Nippon)

    International Nuclear Information System (INIS)

    Fukushima, Michiko; Tamate, Hidetoshi; Sasaki, Yoshiro; Mitsugasira, Satoaki; Masumoto, Kazuyoshi.

    1997-01-01

    Neutron activation analysis facilities at the JMTR reactor was used to determine the levels of trace metals in the livers of nine Japanese sika deer. The samples were cut into pieces, pulverized in liquid nitrogen, freeze-dried, and finally fractionated through a stainless steel sieve of 200 mesh. Then the samples were irradiated for 6 or 24 hours by a neutron flux of 1.0x10 14 n·cm -2 ·sec -1 . In the present work, we analysed the concentrations of six elements (Ag, Co, Fe, Rb, Se, and Zn) in the livers of nine deer. (author)

  11. Trace aluminium determination and sampling problems of archeological bone employing destructive neutron activation analysis

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Rack, E.P.; Recker, R.R.; Leffler, J.A.; Teitelbaum, S.

    1978-01-01

    A destructive neutron activation analysis procedure was developed for determining trace aluminium content in bone. The method is based on a carefully planned sample preparation, irradiation at a neutron flux for 3.1x10 11 nxcm -2 xs -1 for 5 minutes, and chemical separation based on ion exchange. It was found that bone samples soaked in aluminium containing soil gave highly elevated aluminium values as a result of the aluminium adsorption into the bone matrix. The maximum aluminium content values for prehistoric bones are larger than those of modern bones and comparable to aluminium levels present in bone from renal patients. (T.G.)

  12. The determination of trace elements in new food grain SRM's using neutron activation analysis

    International Nuclear Information System (INIS)

    Gills, T.E.; Gallorini, M.; Rook, H.L.

    1978-01-01

    Potentially toxic metals in the food chain that can lead to deleterious effects on human health have been well documented. Because of the toxicity of some metals, levels of 1 ppm or less must be routinely monitored in foods to ensure human safety. To ensure the accuracy of measurement, NBS in a cooperative interagency agreement with the Food and Drug Administration is involved in developing and certifying selected elements in food grain as a part of the Standard Reference Material program. Both instrumental and radiochemical neutron activation analysis were used to analyze two food grain standard reference materials (Rice and Wheat Flours) for trace element certification. (author)

  13. Determination of trace metals and analysis of arsenic species in tropical marine fishes from Spratly islands.

    Science.gov (United States)

    Li, Jingxi; Sun, Chengjun; Zheng, Li; Jiang, Fenghua; Wang, Shuai; Zhuang, Zhixia; Wang, Xiaoru

    2017-09-15

    Trace metal contents in 38 species of tropical marine fishes harvested from the Spratly islands of China were determined by microwave digestion and inductively coupled plasma mass spectrometry analysis. Arsenic species were determined by high-performance liquid chromatography and inductively coupled plasma mass spectrometry analysis. The average levels of Al, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Mo, Cd, Pb, and U in the fish samples were 1.683, 0.350, 0.367, 2.954, 36.615, 0.087, 0.319, 1.566, 21.946, 20.845, 2.526, 3.583, 0.225, 0.140, and 0.061mg·kg -1 , respectively; Fe, Zn, and As were found at high concentrations. The trace metals exhibited significant positive correlation between each other, with r value of 0.610-0.852. Further analysis indicated that AsB (8.560-31.020mg·kg -1 ) was the dominant arsenic species in the fish samples and accounted for 31.48% to 47.24% of the total arsenic. As(III) and As(V) were detected at low concentrations, indicating minimal arsenic toxicity. Copyright © 2017. Published by Elsevier Ltd.

  14. High fidelity analysis of BWR fuel assembly with COBRA-TF/PARCS and trace codes

    International Nuclear Information System (INIS)

    Abarca, A.; Miro, R.; Barrachina, T.; Verdu, G.; Soler, A.

    2013-01-01

    The growing importance of detailed reactor core and fuel assembly description for light water reactors (LWRs) as well as the sub-channel safety analysis requires high fidelity models and coupled neutronic/thermalhydraulic codes. Hand in hand with advances in the computer technology, the nuclear safety analysis is beginning to use a more detailed thermal hydraulics and neutronics. Previously, a PWR core and a 16 by 16 fuel assembly models were developed to test and validate our COBRA-TF/PARCS v2.7 (CTF/PARCS) coupled code. In this work, a comparison of the modeling and simulation advantages and disadvantages of modern 10 by 10 BWR fuel assembly with CTF/PARCS and TRACE codes has been done. The objective of the comparison is making known the main advantages of using the sub-channel codes to perform high resolution nuclear safety analysis. The sub-channel codes, like CTF, permits obtain accurate predictions, in two flow regime, of the thermalhydraulic parameters important to safety with high local resolution. The modeled BWR fuel assembly has 91 fuel rods (81 full length and 10 partial length fuel rods) and a big square central water rod. This assembly has been modeled with high level of detail with CTF code and using the BWR modeling parameters provided by TRACE. The same neutronic PARCS's model has been used for the simulation with both codes. To compare the codes a coupled steady state has be performed. (author)

  15. Application of neutron activation analysis to the monitoring of trace elements in Brazilian foodstuffs

    International Nuclear Information System (INIS)

    Vasconcellos, M.B.A.; Maihara, V.A.; Munita, C.J.A.S.; Favaro, D.I.T.; Armelin, M.J.A.

    1994-01-01

    Due to lack of data on trace element levels in Brazilian foodstuffs, nuclear analytical techniques were used to determine about twenty elements in foods samples collected from local markets of the city of Sao Paulo. Drinking water was also analyzed. The methods employed were mainly instrumental and radiochemical neutron activation analysis. In the case of the analysis of toxic elements, such as mercury, selenium, arsenic and antimony, the purely instrumental approach failed in yielding results for very low concentrations of these elements. For INAA, samples and multielemental synthetic standards were irradiated in the IEA R1 research reactor for periods of time ranging from minutes to several hours, under thermal neutron fluxes from 10 11 to 10 13 n·cm -2 ·s -1 ; after suitable cooling times, γ-ray spectra were measured using a Ge(Li) or Ge solid state detector. The RNAA approach involved the distillation of mercury and selenium in HBr medium; selenium was then reduced to the metal form with sodium metabisulphide and mercury was precipitated as sulphide with thioacetamide. For water analysis, a preconcentration procedure based on retention of several elements in a Chelex-100 resin was employed. The elements retained were Hg, Cr, Zn, Fe, Co while Se was measured in the effluent after absorption on active charcoal. The levels of the trace inorganic elements determined in the Brazilian foodstuffs analyzed were always below the levels established by the existing regulations in our country. (author). 16 refs, 18 tabs

  16. Trace element analysis by EPMA in geosciences: detection limit, precision and accuracy

    Science.gov (United States)

    Batanova, V. G.; Sobolev, A. V.; Magnin, V.

    2018-01-01

    Use of the electron probe microanalyser (EPMA) for trace element analysis has increased over the last decade, mainly because of improved stability of spectrometers and the electron column when operated at high probe current; development of new large-area crystal monochromators and ultra-high count rate spectrometers; full integration of energy-dispersive / wavelength-dispersive X-ray spectrometry (EDS/WDS) signals; and the development of powerful software packages. For phases that are stable under a dense electron beam, the detection limit and precision can be decreased to the ppm level by using high acceleration voltage and beam current combined with long counting time. Data on 10 elements (Na, Al, P, Ca, Ti, Cr, Mn, Co, Ni, Zn) in olivine obtained on a JEOL JXA-8230 microprobe with tungsten filament show that the detection limit decreases proportionally to the square root of counting time and probe current. For all elements equal or heavier than phosphorus (Z = 15), the detection limit decreases with increasing accelerating voltage. The analytical precision for minor and trace elements analysed in olivine at 25 kV accelerating voltage and 900 nA beam current is 4 - 18 ppm (2 standard deviations of repeated measurements of the olivine reference sample) and is similar to the detection limit of corresponding elements. To analyse trace elements accurately requires careful estimation of background, and consideration of sample damage under the beam and secondary fluorescence from phase boundaries. The development and use of matrix reference samples with well-characterised trace elements of interest is important for monitoring and improving of the accuracy. An evaluation of the accuracy of trace element analyses in olivine has been made by comparing EPMA data for new reference samples with data obtained by different in-situ and bulk analytical methods in six different laboratories worldwide. For all elements, the measured concentrations in the olivine reference sample

  17. Analysis of Uncertainty and Sensitivity with TRACE-SUSA and TRACE-DAKOTA. Application to NUPEC BFTB; Analisis de Incertidumbre y Sensibilidad con TRACE-SUSA y TRACE-DAKOTA. Aplicacion a NUPEC BFTB

    Energy Technology Data Exchange (ETDEWEB)

    Montero-Mayorga, J.; Wadim, J.; Sanchez, V. H.

    2012-07-01

    The aim of this work is to test the capabilities of the new tool of uncertainty incorporated into SNAP by simulating experiments with TRACE code and compare these with the results obtained by the same simulations with uncertainty calculation performed with the tool SUSA.

  18. Nuclear techniques for analysis of environmental samples

    International Nuclear Information System (INIS)

    1986-12-01

    The main purposes of this meeting were to establish the state-of-the-art in the field, to identify new research and development that is required to provide an adequate framework for analysis of environmental samples and to assess needs and possibilities for international cooperation in problem areas. This technical report was prepared on the subject based on the contributions made by the participants. A separate abstract was prepared for each of the 9 papers

  19. Limnological aspects and trace element analysis of some selected Kenyan natural inland waters

    International Nuclear Information System (INIS)

    Ochieng, E.O.

    1987-01-01

    This thesis reports the study of trace elements, Ag, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sn, and Zn, and some limnological factors in surface water and sediments in some selected natural inland waters in Kenya. The observed levels are compared with those that are reported in literature to cause interference in biological processes in aquatic environments and human beings. There are little previous data and none that are coherent. These allow for a preliminary assessment of the significance of each element and limnological parameters in the long term stability of the environments in which they occur. XRFA and AAs have been used in the trace elements analysis and the former proved superior in the sediment (solid) samples analysis due to better accuracy and precision of less than 10%. Trace metals concentration (ppb) in the surface inland waters (rivers and lakes ) ranged as follows: Ag (1-75), Cd (2-8), Co (6-23.2), Cr (25-50), Cu (5-57.6), Mn (50-3276±450), Ni (13-34.1), Pb (7-93.6), Sn (300-500) and Zn (25-124.8). Lake sediments had the following concentration (ppm) ranges: Ag (o.098-20.58), Cd (0.188-1.345), Co (0.166-1.632), Cr (1.462-57.310), Cu (1.949-44.350), Mn (667.670-4713), Ni (11.694-56.710), Pb (10.920-192), Sn 17.210-234) and Zn (76.210-229.60). Results show that, a part from the Rift Valley saline lakes, Kenya inland water meet the WHO (1971) drinking water standards related to aquatic living environments. Concentration of some trace metals: Ag, Cd, Cu, Mn and Zn change upon raw water treatments. Preconcentration techniques have been attempted in which preconcentration by evaporation followed by lyophilization of the liquid (water) samples was found more suitable. Bioavailable (total exchangeable) metal concentrations compared very well with the concentrations in the fish muscles. Comparison with the analysis made by earlier investigators indicated a remarkable constancy over time in the chemistry of Lake Victoria and its affluent rivers. Kenyan natural

  20. Trace elemental analysis of carcinoma kidney and stomach by PIXE method

    International Nuclear Information System (INIS)

    Reddy, S. Bhuloka; John Charles, M.; Naga Raju, G.J.; Vijayan, V.; Seetharami Reddy, B.; Ravi Kumar, M.; Sundareswar, B.

    2003-01-01

    Trace elemental analysis was carried out in the biological samples of carcinoma kidney and stomach using particle induced X-ray emission technique. A 2 MeV proton beam was employed to excite the samples. From the present results, the levels of elements K, Ca, Fe, Ni and Se are lower and those of the elements Ti, Co, Zn, As and Cd are higher in the cancer tissue of kidney than those observed in the normal tissue. In the case of stomach, the concentrations of elements Cl, K, Ca, Ti, Mn, Fe, Co, Cu and Zn are lower while concentrations of elements Cr, Ni, As and Br are higher in the cancer tissue of stomach than those observed in the normal tissue. The observed deficiency or excess of certain elements is correlated to carcinogenesis of that organ. The present results of carcinoma stomach support the previous observations that nickel and chromium are carcinogenic agents. The low levels of selenium observed in the carcinoma tissue of kidney and the low levels of manganese observed in the carcinoma tissue of stomach support the view that selenium and manganese inhibit the growth of cancer in kidney and stomach respectively. The observed high levels of zinc in the cancer tissue of kidney suggest that zinc is involved in the tumor growth and development of neoplastic transformation in kidney while the observed low levels of zinc in the carcinoma tissue of stomach suggest that zinc inhibits the growth of cancer in this organ. For correctly assessing the role played by the trace elements in initiating, promoting or inhibiting cancer in various organs, there is a need for acquisition of more data by trace elemental analysis from several investigations of this type undertaken in different regions

  1. Determination of Trace Elements In Soil and Plants In Coastal Basin of Syria By Using Instrumental Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Kassem, A.

    2004-01-01

    Instrumental neutron activation analysis (INAA) methods have been used for the determination of some major, minor and trace elements (As, Cr, Co, Ni, Zn, Sb, Sc Ce, Ti, Fe, Mn and V) in some kinds of plant leaves with their soil. Accuracy of measurements have been evaluated by analyzing a number of plant and soil reference materials, precision have been estimated by triplicate the sample as well as the reference. The obtained accurate and reliable data in microgram quantities of some trace elements in plants and soil will serve as baseline values and will be helpful to monitor the changes in the trace elements content of soil and plant leaves. (Author)

  2. Instrumental neutron activation analysis of site-dependent uptake and distribution of trace elements in the saltmarsh plant Aster tripolium from marsh fields in the Schelde estuary, Netherlands

    International Nuclear Information System (INIS)

    Rossbach, M.

    1986-07-01

    As part of an environmental chemical investigation the uptake of heavy metals by a saltmarsh plant Aster tripolium from two differently polluted salt marsh sites of the North Sea between 20 to 30 trace elements were determined in soil and plant organs. A sensitive gamma ray counting system was installed and tested for instrumental activation analyses (INAA). Installations to improve sensitivity as well as conditions necessary for reliable trace element analysis with the aid of Anticompton spectrometers (ACS) are described. The accuracy and reproducibility of the method was determined by the analysis of reference- and control materials of the german environmental specimen bank. In order to characterise the state of pollution of the salt marsh soils pollution-factors for single elements as well as interelemental correlations were evaluated. In addition, uptake and translocation factors of the biological samples were calculated. The many highly significant correlations between elements within the plant organs indicated that uptake appears to be physiologicaly controlled and not dependent on soil concentration. In order to detect further consequences of differing pollution influences within these plants biochemical separation techniques were applied and trace element levels in selected extracts were determined. For the specification of heavy metals gelpermeation chromatography of ethanolic extracts proved to be the most promising method. Furthermore, propositions for the use of trace elements as a fingerprint for pollution status and characterisation of species for referenz- and specimenbank materials have been developed. Aster tripolium as a cadmium accumulating plant can probably be used as an indicator in the monitoring of cadmium polluted salt marsh areas. (orig.) [de

  3. Space-resolved analysis of trace elements in fresh vegetables using ultraviolet nanosecond laser-induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    Juve, Vincent; Portelli, Richard; Boueri, Myriam; Baudelet, Matthieu; Yu Jin

    2008-01-01

    Laser-induced breakdown spectroscopy (LIBS) has been applied to analyze trace elements contained in fresh vegetables. A quadrupled Nd:YAG laser is used in the experiments for ablation. Analyzed samples come from local markets and represent frequently consumed vegetables. For a typical root vegetable, such as potato, spectral analysis of the plasma emission reveals more than 400 lines emitted by 27 elements and 2 molecules, C 2 and CN. Among these species, one can find trace as well as ultra-trace elements. A space-resolved analysis of several trace elements with strong emissions is then applied to typical root, stem and fruit vegetables. The results from this study demonstrate the potential of an interesting tool for botanical and agricultural studies as well for food quality/safety and environment pollution assessment and control

  4. Ambient analysis of trace compounds in gaseous media by SIFT-MS.

    Science.gov (United States)

    Smith, David; Spaněl, Patrik

    2011-05-21

    The topic of ambient gas analysis has been rapidly developed in the last few years with the evolution of the exciting new techniques such as DESI, DART and EESI. The essential feature of all is that analysis of trace gases can be accomplished either in the gas phase or those released from surfaces, crucially avoiding sample collection or modification. In this regard, selected ion flow tube mass spectrometry, SIFT-MS, also performs ambient analyses both accurately and rapidly. In this focused review we describe the underlying ion chemistry underpinning SIFT-MS through a discourse on the reactions of different classes of organic and inorganic molecules with H(3)O(+), NO(+) and O(2)(+)˙ studied using the SIFT technique. Rate coefficients and ion products of these reactions facilitate absolute SIFT-MS analyses and can also be useful for the interpretation of data obtained by the other ambient analysis methods mentioned above. The essential physics and flow dynamics of SIFT-MS are described that, together with the reaction kinetics, allow SIFT-MS to perform absolute ambient analyses of trace compounds in humid atmospheric air, exhaled breath and the headspace of aqueous liquids. Several areas of research that, through pilot experiments, are seen to benefit from ambient gas analysis using SIFT-MS are briefly reviewed. Special attention is given to exhaled breath and urine headspace analysis directed towards clinical diagnosis and therapeutic monitoring, and some other areas researched using SIFT-MS are summarised. Finally, extensions to current areas of application and indications of other directions in which SIFT-MS can be exploited for ambient analysis are alluded to.

  5. Dynamic leaching and fractionation of trace elements from environmental solids exploiting a novel circulating-flow platform.

    Science.gov (United States)

    Mori, Masanobu; Nakano, Koji; Sasaki, Masaya; Shinozaki, Haruka; Suzuki, Shiho; Okawara, Chitose; Miró, Manuel; Itabashi, Hideyuki

    2016-02-01

    A dynamic flow-through microcolumn extraction system based on extractant re-circulation is herein proposed as a novel analytical approach for simplification of bioaccessibility tests of trace elements in sediments. On-line metal leaching is undertaken in the format of all injection (AI) analysis, which is a sequel of flow injection analysis, but involving extraction under steady-state conditions. The minimum circulation times and flow rates required to determine the maximum bioaccessible pools of target metals (viz., Cu, Zn, Cd, and Pb) from lake and river sediment samples were estimated using Tessier's sequential extraction scheme and an acid single extraction test. The on-line AIA method was successfully validated by mass balance studies of CRM and real sediment samples. Tessier's test in on-line AI format demonstrated to be carried out by one third of extraction time (6h against more than 17 h by the conventional method), with better analytical precision (15% by the conventional method) and significant decrease in blank readouts as compared with the manual batch counterpart. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Dual-Section DFB-QCLs for Multi-Species Trace Gas Analysis

    Directory of Open Access Journals (Sweden)

    Martin J. Süess

    2016-04-01

    Full Text Available We report on the dynamic behavior of dual-wavelength distributed feedback (DFB quantum cascade lasers (QCLs in continuous wave and intermittent continuous wave operation. We investigate inherent etaloning effects based on spectrally resolved light-current-voltage (LIV characterization and perform time-resolved spectral analysis of thermal chirping during long (>5 µs current pulses. The theoretical aspects of the observed behavior are discussed using a combination of finite element method simulations and transfer matrix method calculations of dual-section DFB structures. Based on these results, we demonstrate how the internal etaloning can be minimized using anti-reflective (AR coatings. Finally, the potential and benefits of these devices for high precision trace gas analysis are demonstrated using a laser absorption spectroscopic setup. Thereby, the atmospherically highly relevant compounds CO2 (including its major isotopologues, CO and N2O are simultaneously determined with a precision of 0.16 ppm, 0.22 ppb and 0.26 ppb, respectively, using a 1-s integration time and an optical path-length of 36 m. This creates exciting new opportunities in the development of compact, multi-species trace gas analyzers.

  7. Status of GeoTASO Trace Gas Data Analysis for the KORUS-AQ Campaign

    Science.gov (United States)

    Janz, S. J.; Nowlan, C. R.; Lamsal, L. N.; Kowalewski, M. G.; Judd, L. M.; Wang, J.

    2017-12-01

    The Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) instrument measures spectrally resolved backscattered solar radiation at high spatial resolution. The instrument completed 30 sorties on board the NASA LaRC UC-12 aircraft during the KORUS-AQ deployment in May-June of 2016. GeoTASO collects spatially resolved spectra with sufficient sensitivity to retrieve column amounts of the trace gas molecules NO2, SO2, H2CO, O3, and C2H2O2 as well as aerosol products. Typical product retrievals are done in 250 m2 bins with multiple overpasses of key ground sites, allowing for detailed spatio-temporal analysis. Flight patterns consisted of both contiguous overlapping grid patterns to simulate satellite observational strategies in support of future geostationary satellite algorithm development, and "race-track" sampling to perform calibration and validation with the in-situ DC-8 platform as well as ground based assets. We will summarize the status of the radiance data set as well as ongoing analysis from our co-Investigators.

  8. Quantitative trace element analysis of individual fly ash particles by means of X-ray microfluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Vincze, L.; Somogyi, A.; Osan, J.; Vekemans, B.; Torok, S.; Janssens, K.; Adams, F. [Universitaire of Instelling Antwerp, Wilrijk (Belgium). Dept. of Chemistry

    2002-07-01

    A new quantification procedure was developed for the evaluation of X-ray microfluorescence (XRF) data sets obtained from individual particles, based on iterative Monte Carlo (MC) simulation. Combined with the high sensitivity of synchrotron radiation-induced XRF spectroscopy, the method was used to obtain quantitative information down to trace-level concentrations from micrometer-sized particulate matter. The detailed XRF simulation model was validated by comparison of calculated and experimental XRF spectra obtained for glass microsphere standards, resulting in uncertainties in the range of 3-10% for the calculated elemental sensitivities. The simulation model was applied for the quantitative analysis of X-ray tube and synchrotron radiation-induced scanning micro-XRF spectra of individual coal and wood fly ash particles originating from different Hungarian power plants. By measuring the same particles by both methods the major, minor, and trace element compositions of the particles were determined. The uncertainty of the MC based quantitative analysis scheme is estimated to be in the range of 5-30%.

  9. Trace element analysis of single synthetic fibres by proton induced X-ray analysis in a helium atmosphere

    International Nuclear Information System (INIS)

    Ahmed, M.; Cookson, J.A.

    1976-10-01

    A technique for measuring the trace element content of synthetic fibres by detecting X-rays produced by 3 MeV proton bombardment has been developed. Largely to reduce the problems of removing heat from the fibres, an arrangement was used in which the beam was brought out of the vacuum into air or helium. Kapton, aluminium, nickel and molybdenum were tested for suitability as exit windows. Of these, aluminium produced significantly the most background in X-ray spectra while helium was found to be significantly better than air as the medium around the targets. With a kapton window, helium in the target chamber, and suitable collimation, trace element concentration down to a few parts per million could be measured when quantities of fibre of only a few times 10 -5 g were available for analysis. (author)

  10. Next Generation Offline Approaches to Trace Gas-Phase Organic Compound Speciation: Sample Collection and Analysis

    Science.gov (United States)

    Sheu, R.; Marcotte, A.; Khare, P.; Ditto, J.; Charan, S.; Gentner, D. R.

    2017-12-01

    Intermediate-volatility and semi-volatile organic compounds (I/SVOCs) are major precursors to secondary organic aerosol, and contribute to tropospheric ozone formation. Their wide volatility range, chemical complexity, behavior in analytical systems, and trace concentrations present numerous hurdles to characterization. We present an integrated sampling-to-analysis system for the collection and offline analysis of trace gas-phase organic compounds with the goal of preserving and recovering analytes throughout sample collection, transport, storage, and thermal desorption for accurate analysis. Custom multi-bed adsorbent tubes are used to collect samples for offline analysis by advanced analytical detectors. The analytical instrumentation comprises an automated thermal desorption system that introduces analytes from the adsorbent tubes into a gas chromatograph, which is coupled with an electron ionization mass spectrometer (GC-EIMS) and other detectors. In order to optimize the collection and recovery for a wide range of analyte volatility and functionalization, we evaluated a variety of commercially-available materials, including Res-Sil beads, quartz wool, glass beads, Tenax TA, and silica gel. Key properties for optimization include inertness, versatile chemical capture, minimal affinity for water, and minimal artifacts or degradation byproducts; these properties were assessed with a diverse mix of traditionally-measured and functionalized analytes. Along with a focus on material selection, we provide recommendations spanning the entire sampling-and-analysis process to improve the accuracy of future comprehensive I/SVOC measurements, including oxygenated and other functionalized I/SVOCs. We demonstrate the performance of our system by providing results on speciated VOCs-SVOCs from indoor, outdoor, and chamber studies that establish the utility of our protocols and pave the way for precise laboratory characterization via a mix of detection methods.

  11. Trace element analysis of wild rodent tissues using the PIXE method

    International Nuclear Information System (INIS)

    Hill, M.W.; Mangelson, N.F.; Ryder, J.F.; Atwood, N.D.; Wood, B.W.

    1980-01-01

    Five species of rodents have been collected in an area near Lake Powell Utah. Common names of the five species are: Long-tailed Mouse, Small Pocket Mouse, Deer Mouse, Antelope Ground Squirrel and Kangaroo Rat. Liver, lung, kidney and hair tissues from each animal were analyzed for trace element content by proton particle-induced x-ray emission (proton PIXE) analysis. Mean concentrations for the following elements were established for the tissues of each animal type: K, Ca, Ti, Mn, Fe, Ni, Cu, Zn, Se, Br, Rb and Pb. Analyses of variance were performed on the set of elements common to all tissues. Some significant differences in element concentrations were found between animal species and between tissue types. These differences lead to the following orders based on element concentration: Long-tailed Mouse greater than or equal to Antelope Ground Squirrel greater than or equal to Kangaroo Rat greater than or equal to Small Pocket Mouse and liver greater than or equal to kidney greater than or equal to lung greater than or equal to hair. Linear regression analyses were also performed on mean elemental concentrations in tissues. These analyses lead to several conclusions. First, the pattern of trace element concentrations in each of the four tissues is the same in all five species. Second, the pattern of trace element concentrations is the same in all four tissues of one species with the exception of Ti and Fe in hair. Third, the variation of an element in the hair cannot predict the variation of that same element in the other three tissues. Only K, Ca, Ti, Mn, Fe, Cu, and Zn were included in the third study

  12. Environmental systems analysis of wastewater management

    International Nuclear Information System (INIS)

    Kaerrman, Erik

    2000-01-01

    The history of wastewater management tells us that efforts have been made at solving only one problem at the time; sanitation during the first half of the 20th Century followed by eutrophication of lakes and sea and, for the past ten years, recycling of nutrients. After the 'Brundtland Report', 1987, a reversal of the debate occurred where water management was discussed in a more holistic manner than before. The concept sustainable development became widely accepted and was put into practice. This thesis suggests a framework for evaluating the sustainability of wastewater systems, which contains the use of criteria and system analytical evaluation methods matching each criterion. The main categories of criteria are identified as: Health and Hygiene, Social and Cultural, Environmental, Economic and Functional and Technical. The usability of different concepts of Environmental Systems Analysis for evaluating environmental criteria of wastewater systems is also investigated. These studies show that a substance-flow model combined with evaluation methods from Life Cycle Assessment (LCA), sometimes complemented with Exergy Analysis or Analysis of Primary Energy, is a beneficial approach for evaluating environmental impacts and the usage of resources. The substance-flow model ORWARE (ORganic WAste REsearch) combined with LCA was used to compare four systems structures for the management of household wastewater and solid organic waste, namely Conventional System, Irrigation of Energy Forests, Liquid Composting and Urine Separation. This study shows a potential for further development of the three alternative systems. The comparative study also included some development of system analytical methods. This thesis shows how the contribution from oxidation of ammonia should be included in the eutrophication impact category. Furthermore, a method is given for prioritization of the most relevant impacts from wastewater management by using normalisation of these impacts in

  13. Determination of trace elements in wool fibre by instrumental neutron activation analysis and relation between trace element contents and quality of wool

    International Nuclear Information System (INIS)

    Eozyol, H.

    1990-01-01

    Wool samples were analyzed by neutron activation analysis and 17 elements, Al, Ag, Au, As, Br, Ca, Co, Cr, Cu, Fe, La, Mg, Mn, Na, Sb, Se and Zn were measured quantitatively. The presence of seven others, Ce, Eu, I, Mo, Te and W was noted. Since several elements, such as Cd, Hg and Pb could not be conveniently determined by NAA, Atomic Absorption Spectroscopy (AAS) was used instead. Cu and Zn were also analyzed by NAA and AAS to compare these two methods. Mechanical properties of samples were measured and the relations between the trace element contents and properties were investigated. (author) 16 refs.; 7 tabs

  14. Multivariate statistical analysis to characterize/discriminate between anthropogenic and geogenic trace elements occurrence in the Campania Plain, Southern Italy.

    Science.gov (United States)

    Busico, Gianluigi; Cuoco, Emilio; Kazakis, Nerantzis; Colombani, Nicolò; Mastrocicco, Micòl; Tedesco, Dario; Voudouris, Konstantinos

    2018-03-01

    Shallow aquifers are the most accessible reservoirs of potable groundwater; nevertheless, they are also prone to various sources of pollution and it is usually difficult to distinguish between human and natural sources at the watershed scale. The area chosen for this study (the Campania Plain) is characterized by high spatial heterogeneities both in geochemical features and in hydraulic properties. Groundwater mineralization is driven by many processes such as, geothermal activity, weathering of volcanic products and intense human activities. In such a landscape, multivariate statistical analysis has been used to differentiate among the main hydrochemical processes occurring in the area, using three different approaches of factor analysis: (i) major elements, (ii) trace elements, (iii) both major and trace elements. The elaboration of the factor analysis approaches has revealed seven distinct hydrogeochemical processes: i) Salinization (Cl - , Na + ); ii) Carbonate rocks dissolution; iii) Anthropogenic inputs (NO 3 - , SO 4 2- , U, V); iv) Reducing conditions (Fe 2+ , Mn 2+ ); v) Heavy metals contamination (Cr and Ni); vi) Geothermal fluids influence (Li + ); and vii) Volcanic products contribution (As, Rb). Results from this study highlight the need to separately apply factor analysis when a large data set of trace elements is available. In fact, the impact of geothermal fluids in the shallow aquifer was identified from the application of the factor analysis using only trace elements. This study also reveals that the factor analysis of major and trace elements can differentiate between anthropogenic and geogenic sources of pollution in intensively exploited aquifers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Analysis of DOE international environmental management activities

    Energy Technology Data Exchange (ETDEWEB)

    Ragaini, R.C.

    1995-09-01

    The Department of Energy`s (DOE) Strategic Plan (April 1994) states that DOE`s long-term vision includes world leadership in environmental restoration and waste management activities. The activities of the DOE Office of Environmental Management (EM) can play a key role in DOE`s goals of maintaining U.S. global competitiveness and ensuring the continuation of a world class science and technology community. DOE`s interest in attaining these goals stems partly from its participation in organizations like the Trade Policy Coordinating Committee (TPCC), with its National Environmental Export Promotion Strategy, which seeks to strengthen U.S. competitiveness and the building of public-private partnerships as part of U.S. industrial policy. The International Interactions Field Office task will build a communication network which will facilitate the efficient and effective communication between DOE Headquarters, Field Offices, and contractors. Under this network, Headquarters will provide the Field Offices with information on the Administration`s policies and activities (such as the DOE Strategic Plan), interagency activities, as well as relevant information from other field offices. Lawrence Livermore National Laboratory (LLNL) will, in turn, provide Headquarters with information on various international activities which, when appropriate, will be included in reports to groups like the TPCC and the EM Focus Areas. This task provides for the collection, review, and analysis of information on the more significant international environmental restoration and waste management initiatives and activities which have been used or are being considered at LLNL. Information gathering will focus on efforts and accomplishments in meeting the challenges of providing timely and cost effective cleanup of its environmentally damaged sites and facilities, especially through international technical exchanges and/or the implementation of foreign-development technologies.

  16. Metal and trace element sediment assessment from Salto Grande reservoir, Sao Paulo state, Brazil, by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Walace A.A., E-mail: walace@usp.br [Setor de Analises Toxicologicas. CETESB, Sao Paulo, SP (Brazil); Favaro, Deborah I.T., E-mail: defavaro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Lab. de Analise por Ativacao com Neutrons

    2011-07-01

    The Salto Grande Reservoir is used for electric generation, irrigation, fish farming, recreation and water supply for the region's cities. The reservoir belongs to the city of Americana, located in on the eastern region of Sao Paulo State, Brazil. It belongs to the Piracicaba River Hydrographic Basin, the second most important economic and populated region and one of the most polluted areas in the State. This basin is located in a highly industrialized and agricultural region. Due to urban, industrial and agricultural activities as well as sewage wastes the water and sediments of this reservoir and surroundings are extremely contaminated, mainly by metals, according to CETESB (Environmental Control Agency of the Sao Paulo State). In order to obtain better information about its sediment contamination the present study reports results of the concentration of some major (Ca, Fe, K and Na), trace (As, Ba, Br, Co, Cr, Cs, Hf, Rb, Sb, Se, Ta, Th, U, Zn and rare earth (Ce, Eu, La, Lu, Nd, Sc, Sm, Tb and Yb)) elements in sediments and Cd, Cr, Cu, Ni and Pb concentration in sediments and water from the Salto Grande Reservoir. Multielementar analysis was carried out by Instrumental Neutron Activation Analysis (INAA). Multielemental concentrations in the sediment samples were compared to NASC (North American Shale Composite) values. The concentration values for metals As, Cd, Cr, Cu, Pb, Ni and Zn were compared to the Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL) and adopted by CETESB, (author)

  17. Trace lead analysis based on carbon-screen-printed-electrodes modified via 4-carboxy-phenyl diazonium salt electroreduction

    International Nuclear Information System (INIS)

    Bouden, Sarra; Chausse, Annie; Dorbes, Stephane; El Tall, Omar; Bellakhal, Nizar; Dachraoui, Mohamed; Vautrin-Ul, Christine

    2013-01-01

    This paper describes the use of 4-carboxyphenyl-grafted screen-printed carbon electrodes (4-CP-SPEs) for trace lead analysis.These novel and simple use of electrodes were easily prepared by the electrochemical reduction of the corresponding diazonium salt. Pb detection was then performed by a three-steps method in order to avoid oxygen interference:(i)immersion of the grafted screen-printed electrode (SPE) in the sample and adsorption of Pb(II), (ii)reduction of adsorbed Pb(II) by chrono-amperometry (CA), and (iii) oxidation of Pb by Anodic Square Wave Voltammetry (SWV).The re-oxidation response was exploited for lead detection and quantification. In order to optimize the analytical responses, the influence of the adsorption medium pH and the adsorption time were investigated. Moreover, an interference study was carried out with Cu(II), Hg(II), Al(III), Mn(II), Zn(II), Cd(II) and no major interference can be expected to quantify Pb(II). The described method provided a limit of detection and a limit of quantification of 1.2*10 9 M and 4.1*10 9 M, respectively. These performances indicate that the 4-CP-SPE could be considered as an efficient tool for environmental analysis. (authors)

  18. Metal and trace element sediment assessment from Salto Grande reservoir, Sao Paulo state, Brazil, by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Soares, Walace A.A.; Favaro, Deborah I.T.

    2011-01-01

    The Salto Grande Reservoir is used for electric generation, irrigation, fish farming, recreation and water supply for the region's cities. The reservoir belongs to the city of Americana, located in on the eastern region of Sao Paulo State, Brazil. It belongs to the Piracicaba River Hydrographic Basin, the second most important economic and populated region and one of the most polluted areas in the State. This basin is located in a highly industrialized and agricultural region. Due to urban, industrial and agricultural activities as well as sewage wastes the water and sediments of this reservoir and surroundings are extremely contaminated, mainly by metals, according to CETESB (Environmental Control Agency of the Sao Paulo State). In order to obtain better information about its sediment contamination the present study reports results of the concentration of some major (Ca, Fe, K and Na), trace (As, Ba, Br, Co, Cr, Cs, Hf, Rb, Sb, Se, Ta, Th, U, Zn and rare earth (Ce, Eu, La, Lu, Nd, Sc, Sm, Tb and Yb)) elements in sediments and Cd, Cr, Cu, Ni and Pb concentration in sediments and water from the Salto Grande Reservoir. Multielementar analysis was carried out by Instrumental Neutron Activation Analysis (INAA). Multielemental concentrations in the sediment samples were compared to NASC (North American Shale Composite) values. The concentration values for metals As, Cd, Cr, Cu, Pb, Ni and Zn were compared to the Canadian Council of Minister of the Environment (CCME) oriented values (TEL and PEL) and adopted by CETESB, (author)

  19. Quantitative trace analysis of polyfluorinated alkyl substances (PFAS) in ambient air samples from Mace Head (Ireland): A method intercomparison

    Science.gov (United States)

    Jahnke, Annika; Barber, Jonathan L.; Jones, Kevin C.; Temme, Christian

    A method intercomparison study of analytical methods for the determination of neutral, volatile polyfluorinated alkyl substances (PFAS) was carried out in March, 2006. Environmental air samples were collected in triplicate at the European background site Mace Head on the west coast of Ireland, a site dominated by 'clean' westerly winds coming across the Atlantic. Extraction and analysis were performed at two laboratories active in PFAS research using their in-house methods. Airborne polyfluorinated telomer alcohols (FTOHs), fluorooctane sulfonamides and sulfonamidoethanols (FOSAs/FOSEs) as well as additional polyfluorinated compounds were investigated. Different native and isotope-labelled internal standards (IS) were applied at various steps in the analytical procedure to evaluate the different quantification strategies. Field blanks revealed no major blank problems. European background concentrations observed at Mace Head were found to be in a similar range to Arctic data reported in the literature. Due to trace-levels at the remote site, only FTOH data sets were complete and could therefore be compared between the laboratories. Additionally, FOSEs could partly be included. Data comparison revealed that despite the challenges inherent in analysis of airborne PFAS and the low concentrations, all methods applied in this study obtained similar results. However, application of isotope-labelled IS early in the analytical procedure leads to more precise results and is therefore recommended.

  20. Analysis of results obtained from field tracing test under natural rain condition

    International Nuclear Information System (INIS)

    Mukai, M.; Kamiyama, H.; Tanaka, T.; Wang Zhiming; Zhao Yingjie; Li Zhengtang

    1993-01-01

    As one of the tests arranged by the cooperative research between CIRP and JAERI, field tracing tests using 3 H, 60 Co, 85 Sr and 134 Cs were conducted in pits at the CIRP's field test site located on a loess tableland under natural rain condition. Precipitation amount and evaporation rate were measured to study complicated spatial-temporal behavior of soil water movement under that condition. The evaporation rate was obtained through an analysis on the measured data by a combined method of heat balance and eddy correlation. Numerical model, that is based on piston flow assumption of soil water movement, was developed and applied to determine the behavior of the soil water movement in the pits. Using the determined water movement, 3 H migration was evaluated by numerical simulation. Change of 3 H distribution as a function of elapsed time as well explained by careful evaluation of the soil water movement that carried out before the analysis. (5 figs.)

  1. Sample preparation techniques in trace element analysis by X-ray emission spectroscopy

    International Nuclear Information System (INIS)

    Valkovic, V.

    1983-11-01

    The report, written under a research contract with the IAEA, contains a detailed presentation of the most difficult problem encountered in the trace element analysis by methods of the X-ray emission spectroscopy, namely the sample preparation techniques. The following items are covered. Sampling - with specific consideration of aerosols, water, soil, biological materials, petroleum and its products, storage of samples and their handling. Pretreatment of samples - preconcentration, ashing, solvent extraction, ion exchange and electrodeposition. Sample preparations for PIXE - analysis - backings, target uniformity and homogeneity, effects of irradiation, internal standards and specific examples of preparation (aqueous, biological, blood serum and solid samples). Sample preparations for radioactive sources or tube excitation - with specific examples (water, liquid and solid samples, soil, geological, plants and tissue samples). Finally, the problem of standards and reference materials, as well as that of interlaboratory comparisons, is discussed

  2. Interfering line in trace analysis by X-ray spectrometry: Radiative auger satellites

    International Nuclear Information System (INIS)

    Maeda, Kuniko; Kawai, Jun.

    1994-01-01

    Strong characteristic X-ray lines (e.g. Kα and Kβ) are accompanied by broad low-energy satellites caused by the radiative Auger effect (RAE). In order to prove how the RAE satellites interfere the analysis of minor elements, low-energy side spectra of Ca and Ti Kβ, and Ca-Fe Kα were measured. The obtained RAE intensities are summarized together with published experimental and theoretical data. The integrated intensities of satellites due to K → MM, K → LM and K → LL RAE relative to that of Kα are determined to be of the order of 0.01-0.1%. This warns that the neglecting of the RAE satellites will introduce a serious error in trace analysis. (author)

  3. Proton induced x-ray emission analysis of trace elements in thick bread samples

    International Nuclear Information System (INIS)

    Mohamed Baker Al-bedri; Ikram Jameel Abdul Ghani; Ibrahim Abdul Rahman Al-aghil

    2009-01-01

    Proton induced X-ray emission (PIXE) technique has been used for identification and quantitative analysis of the elemental concentration in thick bread samples. Bread samples were air-oven dried at 60degC and milled in a clean agate mortar to homogenize the sample and pressed into a pellet. PIXE technique relies on the analysis of the energy spectra of the characteristic X-ray emitted from the thick bread sample and the orchard leaf standard (NIST-SRM-1571) bombarded with 2.0 MeV protons. The concentration of the elements (Cl, K, Ca, Mn, Fe, Cu, and Zn) in the bread samples was determined by comparison with NIST orchard leaf standard. The accuracy of the measurements ranged between ±2% and ±10% for the most elements detected in this method. The aim of this study is to establish the reference concentration of trace elements in the Iraqi bread using PIXE technique. (author)

  4. Determination of trace elements of Egyptian crops by neutron activation analysis Pt. 3

    International Nuclear Information System (INIS)

    Sherif, M.K.; Awadallah, R.M.; Amrallah, A.H.

    1980-01-01

    Multielemental neutron activation analysis was used for the determination of Al, As, Au, Br, Ca, Cd, Co, Cr, Cu, Fe, La, Mn, Mo, Sb, Se, W and Zn in African tea and lady's fingers (Malvaceae Family), ginger (Zingiperanceae Family), canella bark (Laureceae Family), black pepper (Piperaceae Family), cucumber seeds and vegetable marrow seeds (Cucurbitaceae Family), tomatos seed (Solanaceae Family), safflower seeds (Compositae Family), jew's mallow seed (Tiliaceae Family) and sesame (Pedaliaceae Family). Trace elements determination was made for the analysis of destructive (using super pure nitric acid and adsorbing the metal-APDC and metal-Dz complexes on activated charcoal) and nondestructive (dry seeds) samples. The method is simple, precise and sensitive for the determination of microamounts of the elements (ppm to ppb). (author)

  5. Tracing transfer processes of metal pollutants from soils to surface water using environmental magnetic techniques - results from Paris suburbia (France)

    Science.gov (United States)

    Franke, Christine; Lamy, Isabelle; van Oort, Folkert; Thiesson, Julien; Barsalini, Luca

    2015-04-01

    Major river systems in Europe are potential sinks for environmental pollutions and therefore reflect the consequences of European industrialization and urbanization. Surface water pollution is a major concern for the health of the population and its related ecosystems as well as for the water quality. Within the variety of different typical pollutants in a river watershed, the metallic fraction embraces many toxic/dangerous contaminants. Each of these elements comprises different sources and follows specific processes throughout its pathways from its origin to and within the river system. But the detection, estimation and follow up of the different contaminants is highly complex. Physico-chemical techniques such as environmental and rock magnetics are powerful complementary tools to traditional methods because they comprise the possibility to trace the entire metal fraction and do offer the possibility to perform spatio-temporal analyze campaigns directly in the field and on a relative high number of samples from both the river and the adjacent areas (suspended particular matter, soils, dust, sediments, etc). In this study, we took advantages of the recent results on the Seine river (France) that have shown the high potential of environmental magnetic methods to estimate the metal fraction in suspended particular matter samples, and to allow the discrimination of its natural detrital, biogenic or anthropogenic origin (see parallel EGU abstract of Kayvantash et al. in this session). We focused on a suburban agricultural area west of Paris (Pierrelaye-Bessancourt) adjacent to the Seine river, which suffers from a high accumulation of heavy metal pollutants caused by long-term historical irrigation with urban waste waters. For the time being, these heavy metals seem to be geochemically fixed in the surface layer mainly by the soil organic matter. Future land use planning, however, arises questions on the fate of these pollutants and their potential remobilization by

  6. Qualitative and quantitative analysis of environmental samples by laser-induced breakdown spectrometry

    International Nuclear Information System (INIS)

    Zorov, N B; Popov, A M; Zaytsev, S M; Labutin, T A

    2015-01-01

    The key achievements in the determination of trace amounts of components in environmental samples (soils, ores, natural waters, etc.) by laser-induced breakdown spectrometry are considered. Unique capabilities of this method make it suitable for rapid analysis of metals and alloys, glasses, polymers, objects of cultural heritage, archaeological and various environmental samples. The key advantages of the method that account for its high efficiency are demonstrated, in particular, a small amount of analyzed material, the absence of sample preparation, the possibility of local and remote analysis of either one or several elements. The use of chemometrics in laser-induced breakdown spectrometry for qualitative sample classification is described in detail. Various approaches to improving the figures of merit of quantitative analysis of environmental samples are discussed. The achieved limits of detection for most elements in geochemical samples are critically evaluated. The bibliography includes 302 references

  7. Trace elements controlling the atmospheric circulation. Atmospheric environmental research as part of future FhG research

    Energy Technology Data Exchange (ETDEWEB)

    1986-11-01

    Atmospheric trace substances such as methane (CH/sub 4/), ozone and nitrogen oxides (NO/sub x/) essentially influence the biosphere. FhG research work will be consisting in the long-term measurement of trace substance concentrations in different places (e.g. South Africa, Italy, Thailand or China). An air container packed with measuring instruments and data storage equipment was sent to South America with scientists on board measuring the distribution of trace substances over the northern and southern hemisphere.

  8. Analysis of internal doses to Mole voles inhabiting the East-Ural radioactive trace

    Energy Technology Data Exchange (ETDEWEB)

    Malinovsky, G.; Yarmoshenko, I. [Institute of Industrial Ecology UB RAS (Russian Federation); Chibiryak, M.; Vasil' ev, A. [Institute of Plant and Animal Ecology UB RAS (Russian Federation)

    2014-07-01

    Substantial task of development of approaches to radiation protection of non-human biota is investigation of relationships of exposure to dose, and dose to effects. Small mammals inhabiting territory of the East-Ural Radioactive Trace (EURT) are affected to ionizing radiation for many generations after accident at Mayak plutonium production in 1957. According to results of numerous studies a number of effects of exposure are observed. It is remarkable that the revealed effects are both negative and adaptive. In particular, the analysis of the variability of morphological structures of the axial skull and lower jaw in the population of northern mole vole (Ellobius talpinus Pall.), the burrowing rodent inhabiting the EURT, is of great interest. At the same time there is no reliable assessment of the radiation doses to these animals. Earlier we developed the approach to assess internal doses to mouse-like rodents (mice and voles) caused by incorporated {sup 90}Sr, which is the main dose contributing radionuclide at the EURT. Dose assessments are based on the results of beta-radiometry of intact bone. Routine methods for measuring the activity concentration of {sup 90}Sr in skeleton require ashing of samples, however in morphometric studies the destruction of material should be avoided: the skulls of mole voles are stored in the environmental samples depository of IPAE. Coefficients linking results of beta-radiometry of intact bone and activity concentration of {sup 90}Sr in skull of mouse was obtained basing on comparison of results of beta-radiometry of intact bone and bone ash. Obtained coefficients cannot be directly applied for calculating activity concentration of {sup 90}Sr in mole vole skulls because they are significantly larger. Therefore the additional study is required to assess proper coefficient of conversion from beta-radiometry to activity concentration of {sup 90}Sr. Developed dose assessment procedure includes application of the published values of

  9. A multi-element solid-phase extraction method for trace metals determination in environmental samples on Amberlite XAD-2000

    International Nuclear Information System (INIS)

    Bulut, Volkan Numan; Gundogdu, Ali; Duran, Celal; Senturk, Hasan Basri; Soylak, Mustafa; Elci, Latif; Tufekci, Mehmet

    2007-01-01

    A method for the preconcentration of some transition elements at trace level was proposed using a column filled with Amberlite XAD-2000 resin. Metal ions were adsorbed on XAD-2000 as their diethyldithiocarbamate chelates, then analytes retained on the resin were eluted by 1 mol L -1 nitric acid in acetone and determined by flame atomic absorption spectrometry (FAAS). The influences of some analytical parameters including pH of sample solution, ligand amount, the type, concentration and volume of elution solution, flow rates of the sample and eluent solutions, adsorption capacity of the resin and sample volume on the preconcentration efficiency have been investigated. The influences of some matrix elements were also examined. The detection limit (N = 20, 3 sigma) for Mn(II), Fe(II), Co(II), Cu(II), Cd(II), Zn(II), Pb(II) and Ni(II) were found as 0.20, 0.35, 0.25, 0.20, 0.20, 0.15, 0.45 and 0.25 μg L -1 , respectively. The validation of the procedure was carried out by analysis of certified reference materials. The proposed method was applied to natural waters and kale vegetable (Brassica oleracea var. acephala)

  10. A multi-element solid-phase extraction method for trace metals determination in environmental samples on Amberlite XAD-2000

    Energy Technology Data Exchange (ETDEWEB)

    Bulut, Volkan Numan [Department of Chemistry, Giresun Faculty of Arts and Sciences, Karadeniz Technical University, 28049 Giresun (Turkey); Gundogdu, Ali [Department of Chemistry, Faculty of Arts and Sciences, Karadeniz Technical University, 61080 Trabzon (Turkey); Duran, Celal [Department of Chemistry, Faculty of Arts and Sciences, Karadeniz Technical University, 61080 Trabzon (Turkey); Senturk, Hasan Basri [Department of Chemistry, Faculty of Arts and Sciences, Karadeniz Technical University, 61080 Trabzon (Turkey); Soylak, Mustafa [Department of Chemistry, Faculty of Arts and Sciences, Erciyes University, 38039 Kayseri (Turkey)]. E-mail: msoylak@gmail.com; Elci, Latif [Department of Chemistry, Faculty of Arts and Sciences, Pamukkale University, 20020 Denizli (Turkey); Tufekci, Mehmet [Department of Chemistry, Faculty of Arts and Sciences, Karadeniz Technical University, 61080 Trabzon (Turkey)

    2007-07-19

    A method for the preconcentration of some transition elements at trace level was proposed using a column filled with Amberlite XAD-2000 resin. Metal ions were adsorbed on XAD-2000 as their diethyldithiocarbamate chelates, then analytes retained on the resin were eluted by 1 mol L{sup -1} nitric acid in acetone and determined by flame atomic absorption spectrometry (FAAS). The influences of some analytical parameters including pH of sample solution, ligand amount, the type, concentration and volume of elution solution, flow rates of the sample and eluent solutions, adsorption capacity of the resin and sample volume on the preconcentration efficiency have been investigated. The influences of some matrix elements were also examined. The detection limit (N = 20, 3 sigma) for Mn(II), Fe(II), Co(II), Cu(II), Cd(II), Zn(II), Pb(II) and Ni(II) were found as 0.20, 0.35, 0.25, 0.20, 0.20, 0.15, 0.45 and 0.25 {mu}g L{sup -1}, respectively. The validation of the procedure was carried out by analysis of certified reference materials. The proposed method was applied to natural waters and kale vegetable (Brassica oleracea var. acephala)

  11. TRACE/PARCS analysis of the OECD/NEA Oskarshamn-2 BWR stability benchmark

    Energy Technology Data Exchange (ETDEWEB)

    Kozlowski, T. [Univ. of Illinois, Urbana-Champaign, IL (United States); Downar, T.; Xu, Y.; Wysocki, A. [Univ. of Michigan, Ann Arbor, MI (United States); Ivanov, K.; Magedanz, J.; Hardgrove, M. [Pennsylvania State Univ., Univ. Park, PA (United States); March-Leuba, J. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Hudson, N.; Woodyatt, D. [Nuclear Regulatory Commission, Rockville, MD (United States)

    2012-07-01

    On February 25, 1999, the Oskarshamn-2 NPP experienced a stability event which culminated in diverging power oscillations with a decay ratio of about 1.4. The event was successfully modeled by the TRACE/PARCS coupled code system, and further analysis of the event is described in this paper. The results show very good agreement with the plant data, capturing the entire behavior of the transient including the onset of instability, growth of the oscillations (decay ratio) and oscillation frequency. This provides confidence in the prediction of other parameters which are not available from the plant records. The event provides coupled code validation for a challenging BWR stability event, which involves the accurate simulation of neutron kinetics (NK), thermal-hydraulics (TH), and TH/NK. coupling. The success of this work has demonstrated the ability of the 3-D coupled systems code TRACE/PARCS to capture the complex behavior of BWR stability events. The problem was released as an international OECD/NEA benchmark, and it is the first benchmark based on measured plant data for a stability event with a DR greater than one. Interested participants are invited to contact authors for more information. (authors)

  12. Trace Elements in the Conductive Tissue of Beef Heart Determined by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Wester, P.O.

    1965-08-01

    By means of neutron activation analysis, samples of four beef hearts taken from the bundle of His and adjacent ventricular muscle, the AV node and adjacent atrial muscle are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent γ-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, .Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, W and Zn. In the conductive tissue compared to adjacent muscle tissue, calculations on a wet weight basis show a lower concentration of Cs, Cu, Fe, K, P, Rb and Zn in the former, and a higher concentration of Ag, Au, Br, Ca and Na. The mean differences (μg/g wet tissue), as well as their degree of significance, between the bundle of His and adjacent tissue from the ventricular septum, between the AV node and adjacent atrial muscle, between the ventricular septum and the right atrium, and between the bundle of His and the AV node are given for the elements Cu, Fe, K, Na, P and Zn

  13. Trace Elements in the Conductive Tissue of Beef Heart Determined by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wester, P O

    1965-08-15

    By means of neutron activation analysis, samples of four beef hearts taken from the bundle of His and adjacent ventricular muscle, the AV node and adjacent atrial muscle are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent {gamma}-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, .Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, W and Zn. In the conductive tissue compared to adjacent muscle tissue, calculations on a wet weight basis show a lower concentration of Cs, Cu, Fe, K, P, Rb and Zn in the former, and a higher concentration of Ag, Au, Br, Ca and Na. The mean differences ({mu}g/g wet tissue), as well as their degree of significance, between the bundle of His and adjacent tissue from the ventricular septum, between the AV node and adjacent atrial muscle, between the ventricular septum and the right atrium, and between the bundle of His and the AV node are given for the elements Cu, Fe, K, Na, P and Zn.

  14. Development of Ray Tracing Algorithms for Scanning Plane and Transverse Plane Analysis for Satellite Multibeam Application

    Directory of Open Access Journals (Sweden)

    N. H. Abd Rahman

    2014-01-01

    Full Text Available Reflector antennas have been widely used in many areas. In the implementation of parabolic reflector antenna for broadcasting satellite applications, it is essential for the spacecraft antenna to provide precise contoured beam to effectively serve the required region. For this purpose, combinations of more than one beam are required. Therefore, a tool utilizing ray tracing method is developed to calculate precise off-axis beams for multibeam antenna system. In the multibeam system, each beam will be fed from different feed positions to allow the main beam to be radiated at the exact direction on the coverage area. Thus, detailed study on caustics of a parabolic reflector antenna is performed and presented in this paper, which is to investigate the behaviour of the rays and its relation to various antenna parameters. In order to produce accurate data for the analysis, the caustic behaviours are investigated in two distinctive modes: scanning plane and transverse plane. This paper presents the detailed discussions on the derivation of the ray tracing algorithms, the establishment of the equations of caustic loci, and the verification of the method through calculation of radiation pattern.

  15. Determination of trace elements: Neutron-activation analysis in geochemistry and cosmochemistry

    International Nuclear Information System (INIS)

    Kolesov, G.M.

    1994-01-01

    Geochemistry, like cosmochemistry, open-quotes studies chemical elements hor-ellipsis of the crust and hor-ellipsis the Earth hor-ellipsis their history, their distribution hor-ellipsis their genetic hor-ellipsis connectionsclose quotes and is based on data on the abundance and distribution of elements obtained by various analytical methods. Neutron-activation analysis (NAA) plays a particular role in this respect. This is due to its high sensitivity (detection limit as small as 10 -14 g), which makes possible the use of samples of arbitrary mass, and also due to the possibility of obtaining information about composition without destruction of the object, conserving, if required, the unique material under investigation. Of the most interest are the data on the contents for a number of trace elements (at a level of 10 -7 - 10 -4 %), among which are rare-earth elements (REE), U, Th, Zr, Hf, Ta, W, Ga, Ni, Rb, Cs, platinum-group metals, Ag, Au, etc. These elements are considered as indicators of geochemical processes associated with the genesis and evolution of solar system bodies in early and more recent stages of evolution; they are also used to study processes and phenomena at zone boundaries: river-sea, ocean-atmosphere, and so on. The aim of this work is to show the capabilities of NAA in the determination of trace elements

  16. Microbial population analysis improves the evidential value of faecal traces in forensic investigations.

    Science.gov (United States)

    Quaak, Frederike C A; de Graaf, Mei-Lan M; Weterings, Rob; Kuiper, Irene

    2017-01-01

    The forensic science community has a growing interest in microbial population analysis, especially the microbial populations found inside and on the human body. Both their high abundance, microbes outnumber human cells by a factor 10, and their diversity, different sites of the human body harbour different microbial communities, make them an interesting tool for forensics. Faecal material is a type of trace evidence which can be found in a variety of criminal cases, but is often being ignored in forensic investigations. Deriving a human short tandem repeat (STR) profile from a faecal sample can be challenging. However, the microbial communities within faecal material can be of additional criminalistic value in linking a faecal trace to the possible donor. We present a microarray technique in which the faecal microbial community is used to differentiate between faecal samples and developed a decision model to predict the possible common origin of questioned samples. The results show that this technique may be a useful additional tool when no or only partial human STR profiles can be generated.

  17. Trace elements determinations in cancerous and non-cancerous human tissues using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Choi, Insup.

    1989-01-01

    Recent improvements in analyzing techniques when coupled to the growing knowledge of trace element biochemistry provide a powerful tool to investigate the relationship between trace elements and cancer. It is hoped that selective delivery or restriction of specific minerals may aid in cancer prevention or treatment. Tissues were collected at the time of surgery of various cancer patients including colon cancer and breast cancer. Three kinds of tissues were taken from a patient; cancerous, noncancerous, and transitional tissue obtained from a region located between the cancer and healthy tissues. A total of 57 tissues were obtained from 19 cancer patients. Seven of them were colon cancer patients, and 5 of them were breast cancer patients. Nine elements were determined using instrumental activation analysis. Cancerous colon tissue had significantly higher concentrations of selenium and iron than healthy tissues. Cancerous breast tissue had significantly higher concentrations of selenium, iron, manganese, and rubidium than healthy tissues. Iron can be enriched in cancer tissue because cancer tissue retains more blood vessels. Selenium is enriched in cancer tissue, possibly in an effort of the body to inhibit the growth of tumors. The manganese enrichment can be explained in the same manner as selenium considering its suspected anticarcinogenicity. It is not certain why rubidium was enriched in cancer tissue. It could be that this is the result of alteration of cell membrane permeability, change in extracellular matrix, or increased metabolism in cancer tissue

  18. Trace element contents in atmospheric suspended particles: inferences from instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Querol, X.; Alastuey, A.; Lopez-Soler, A.; Boix, A.; Sanfeliu, T.; Martynov, V.V.; Piven, P.I.; Kabina, L.P.; Souschov, P.A.

    1997-01-01

    This study focuses on the determination of trace element concentrations in total suspended particles by instrumental neutron activation analysis (INAA) in two different areas in Northeastern Spain (a rural area influenced by the emissions of a large coal-fired power station, and the urban and industrial areas of Castellon). Total suspended particles were sampled by means of standard MCV high- and medium-volume captors, using cellulose membrane filters of 0.8 and 0.45 μm pore size. Preliminary research was performed on the homogeneous distribution of elements in the sample filters and on the study of blank filters for the calculations of the background average element contents. The results obtained allowed to distinguish different major anthropogenic sources of trace elements in the atmosphere at the sampling sites: (a) Zr, Hf, Sc, U and Th are related to atmospheric pollution derived from the ceramic industry of the Castellon area; (b) As, Cr, Cs, Rb, Sb, Se, Zn are related to traffic and other industrial emission in the Castellon area, and As, Cr, Sb and Zn to power generation emissions in the rural area. (orig.). With 3 figs., 5 tabs

  19. Determination of minor-and trace elements in magnesite samples, by activation analysis

    International Nuclear Information System (INIS)

    Sepulveda Munita, C.J.A.

    1979-01-01

    A method employing activation analysis with thermal neutron was developed for the determination of minor and trace elements in magnesite samples from the states of Ceara and Bahia (Brazil). Ten samples were analyzed. A qualitative analysis of the samples indicated the presence of Mn, Fe, Sc, Ca, Cu, Co and some of the lanthanides. The experimental part includes a non-destructive analysis of manganese and analysis with chemical separation of the other elements, individually or in groups, after sample dissolution, The dissolutions were made with concentrated HCl and the further separations were carried out in 8 N HCl medium. Iron was separated by means of an extraction of HFeCl 4 with isopropyl ether. Scandium and calcium were determined by retention of scandium with di-(2-ehylhexyl) phosphoric acid (HDEHP). The activities of 46 Sc and 47 Sc (a 47 Ca descendant) were employed for the analysis of scandium and calcium in the sample. In the effluent of the kieselguhr column copper and cobalt were determined, after retention in an anionic resin of the CuCl - 3 and CoCl - 3 complexes. Finally, in the effluent of the resin, the lanthanide group was separated by oxalate precipitation. In the gamma-ray spectrum of this precipitate the elements europium, cerium, samarium and lanthanum were determined. A detailed study of the possible interferences in the neutron activation analysis of the elements analysed was also made. The precision and accuracy of the results obtained and the sensitivity of the method are discussed. (Author) [pt

  20. Stripping voltammetry in environmental and food analysis.

    Science.gov (United States)

    Brainina, K Z; Malakhova, N A; Stojko, N Y

    2000-10-01

    The review covers over 230 papers published mostly in the last 5 years. The goal of the review is to attract the attention of researchers and users to stripping voltammetry in particular, its application in environmental monitoring and analysis of foodstuffs. The sensors employed are impregnated graphite, carbon paste, thick film carbon/graphite and thin film metallic electrodes modified in-situ or beforehand. Hanging mercury drop electrodes and mercury coated glassy carbon electrodes are also mentioned. Strip and long-lived sensors for portable instruments and flow through systems are discussed as devices for future development and application of stripping voltammetry.

  1. Trace analysis of auxiliary feedwater capacity for Maanshan PWR loss-of-normal-feedwater transient

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Che-Hao; Shih, Chunkuan [National Tsing Hua Univ., Taiwan (China). Inst. of Nuclear Engineering and Science; Wang, Jong-Rong; Lin, Hao-Tzu [Atomic Energy Council, Taiwan (China). Inst. of Nuclear Energy Research

    2013-07-01

    Maanshan nuclear power plant is a Westinghouse PWR of Taiwan Power Company (Taipower, TPC). A few years ago, TPC has made many assessments in order to uprate the power of Maanshan NPP. The assessments include NSSS (Nuclear Steam Supply System) parameters calculation, uncertainty acceptance, integrity of pressure vessel, reliability of auxiliary systems, and transient analyses, etc. Since the Fukushima Daiichi accident happened, it is necessary to consider transients with multiple-failure. Base on the analysis, we further study the auxiliary feedwater capability for Loss-of-Normal-Feedwater (LONF) transient. LONF is the limiting transient of non-turbine trip initiated event for ATWS (Anticipated Transient Without Scram) which results in a reduction in capability of the secondary system to remove the heat generated in the reactor core. If the turbine fails to trip immediately, the secondary water inventory will decrease significantly before the actuation of auxiliary feedwater (AFW) system. The heat removal from the primary side decreases, and this leads to increases of primary coolant temperature and pressure. The water level of pressurizer also increases subsequently. The heat removal through the relief valves and the auxiliary feedwater is not sufficient to fully cope with the heat generation from primary side. The pressurizer will be filled with water finally, and the RCS pressure might rise above the set point of relief valves for water discharge. RCS pressure depends on steam generator inventory, primary coolant temperature, negative reactivity feedback, and core power, etc. The RCS pressure may reach its peak after core power reduction. According to ASME Code Level C service limit criteria, the Reactor Coolant System (RCS) pressure must be under 22.06 MPa. The USNRC is developing an advanced thermal hydraulic code named TRACE for nuclear power plant safety analysis. The development of TRACE is based on TRAC and integrating with RELAP5 and other programs. SNAP

  2. Trace analysis of auxiliary feedwater capacity for Maanshan PWR loss-of-normal-feedwater transient

    International Nuclear Information System (INIS)

    Chen, Che-Hao; Shih, Chunkuan; Wang, Jong-Rong; Lin, Hao-Tzu

    2013-01-01

    Maanshan nuclear power plant is a Westinghouse PWR of Taiwan Power Company (Taipower, TPC). A few years ago, TPC has made many assessments in order to uprate the power of Maanshan NPP. The assessments include NSSS (Nuclear Steam Supply System) parameters calculation, uncertainty acceptance, integrity of pressure vessel, reliability of auxiliary systems, and transient analyses, etc. Since the Fukushima Daiichi accident happened, it is necessary to consider transients with multiple-failure. Base on the analysis, we further study the auxiliary feedwater capability for Loss-of-Normal-Feedwater (LONF) transient. LONF is the limiting transient of non-turbine trip initiated event for ATWS (Anticipated Transient Without Scram) which results in a reduction in capability of the secondary system to remove the heat generated in the reactor core. If the turbine fails to trip immediately, the secondary water inventory will decrease significantly before the actuation of auxiliary feedwater (AFW) system. The heat removal from the primary side decreases, and this leads to increases of primary coolant temperature and pressure. The water level of pressurizer also increases subsequently. The heat removal through the relief valves and the auxiliary feedwater is not sufficient to fully cope with the heat generation from primary side. The pressurizer will be filled with water finally, and the RCS pressure might rise above the set point of relief valves for water discharge. RCS pressure depends on steam generator inventory, primary coolant temperature, negative reactivity feedback, and core power, etc. The RCS pressure may reach its peak after core power reduction. According to ASME Code Level C service limit criteria, the Reactor Coolant System (RCS) pressure must be under 22.06 MPa. The USNRC is developing an advanced thermal hydraulic code named TRACE for nuclear power plant safety analysis. The development of TRACE is based on TRAC and integrating with RELAP5 and other programs. SNAP

  3. PIXE analysis of trace and other mineral elements in Romanian dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Iordan, Andreea; Harangus, Livia; Ciortea, C.; Moldovan, Maria

    2002-01-01

    Dental composites made of silicates and oxides particles embedded in an organic polymer, show a dynamic evolution but are rather expensive. Recently, the Romanian biomaterial 'Restacril' offered a low-cost alternative. Because the durability of the composite dental fillings depends both on the main chemical composition and on the impurities that may influence the inorganic particles' properties and thus modifying the bio material clinical behaviour, the elemental analysis of the material is necessary for improving its quality. Particle-induced X-ray emission (PIXE), a sensitive method for multielemental trace detection widely used in biomedical applications, allowed us to evidence 21 mineral elements with Z > 14 in some commercial dental composites. Here we evaluate the performances of PIXE for the control of dental composites by carrying out qualitative analysis of three Romanian biomaterials. PIXE measurements on thick composite samples with a flat surface were done with 3 MeV protons at the NIPNE-HH (Horia Hulubei National Institute for Physics and Nuclear Engineering) tandem accelerator, using a hyper-pure Ge detector, 30 mm thick Al absorber foil and integration of beam current. Up to 21 elements with Z > 19 were detected: K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Ga, Sr, Zr, Nb, Ru, Ag, Ba, Yb, Nd, Hf, Au, As and Pb. The orders of magnitude of relative concentrations were evaluated using X-ray yields obtained for another light element thick composite target. The Romanian composites have specific and diverse compositions, containing a great number of minor and trace elements, many of whom are impurities. Use of higher purity raw materials is suggested to reduce the latter and improve the materials' quality. Refinement of X-ray yields by better matching matrixes calculations and use of concentration standards are proposed for quantitative PIXE analysis of the dental composites. (authors)

  4. Tracing diffuse anthropogenic Pb sources in rural soils by means of Pb isotope analysis

    NARCIS (Netherlands)

    Walraven, N.; Gaans, P.F.M. van; Veer, G. van der; Os, B.J.H. van; Klaver, G.T.; Vriend, S.P.; Middelburg, J.J.; Davies, G.R.

    2013-01-01

    Knowledge of the cause and source of Pb pollution is important to abate environmental Pb pollution by taking source-related actions. Lead isotope analysis is a potentially powerful tool to identify anthropogenic Pb and its sources in the environment. Spatial information on the variation of

  5. Collection and preparation of bottom sediment samples for analysis of radionuclides and trace elements

    International Nuclear Information System (INIS)

    2003-07-01

    The publication is the first in a series of TECDOCs on sampling and sample handling as part of the IAEA support to improve reliability of nuclear analytical techniques (NATs) in Member State laboratories. The purpose of the document is to provide information on the methods for collecting sediments, the equipment used, and the sample preparation techniques for radionuclide and elemental analysis. The most appropriate procedures for defining the strategies and criteria for selecting sampling locations, for sample storage and transportation are also given. Elements of QA/QC and documentation needs for sampling and sediment analysis are discussed. Collection and preparation of stream and river bottom sediments, lake bottom sediments, estuary bottom sediments, and marine (shallow) bottom sediments are covered. The document is intended to be a comprehensive manual for the collection and preparation of bottom sediments as a prerequisite to obtain representative and meaningful results using NATs. Quality assurance and quality control (QA/QC) is emphasized as an important aspect to ensure proper collection, transportation, preservation, and analysis since it forms the basis for interpretation and legislation. Although there are many approaches and methods available for sediment analyses, the scope of the report is limited to sample preparation for (1) analysis of radionuclides (including sediment dating using radionuclides such as Pb-210 and Cs-137) and (2) analysis of trace, minor and major elements using nuclear and related analytical techniques such as NAA, XRF and PIXE

  6. Trace Analysis of Irradiated Granite Samples from Hiroshima by Laser Ablation Inductively Coupled Plasma Mass Spectrometry

    International Nuclear Information System (INIS)

    Amr, M.A.; Helal, N.F.; Zahran, N.F.; Becker, J.S.; Pickhardt, C.; Dietze, H.J.

    1999-01-01

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is widely accepted as a rapid and sensitive technique for trace elemental analysis of solid materials and for local analysis of inhomogeneous materials (such as geological samples). Due to its direct solid sample analysis capability, LA-ICP-MS (using a quadrupole based ICP-MS and at the Research Center Juelich developed laser ablation system: Nd-YAG-laser, 226 nm, 10 Hz and 5 ns) is applied for the analysis of geological (granite) samples from Hiroshima. In order to prepare homogeneous targets, these samples were melted together with a lithium-borate mixture in a muffle furnace at 1050 degree c. Furthermore, for investigating of matrix effects the powder of these samples is mixed with graphite and pressed as targets for laser ablation. The quantification of the analysis results was carried out using granite (GM) as standard reference material. The relative sensitivity coefficients (RSCs) for most elements, which were determined for correction of the measured values, varied between 0.3 and 3

  7. Collection and preparation of bottom sediment samples for analysis of radionuclides and trace elements

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    The publication is the first in a series of TECDOCs on sampling and sample handling as part of the IAEA support to improve reliability of nuclear analytical techniques (NATs) in Member State laboratories. The purpose of the document is to provide information on the methods for collecting sediments, the equipment used, and the sample preparation techniques for radionuclide and elemental analysis. The most appropriate procedures for defining the strategies and criteria for selecting sampling locations, for sample storage and transportation are also given. Elements of QA/QC and documentation needs for sampling and sediment analysis are discussed. Collection and preparation of stream and river bottom sediments, lake bottom sediments, estuary bottom sediments, and marine (shallow) bottom sediments are covered. The document is intended to be a comprehensive manual for the collection and preparation of bottom sediments as a prerequisite to obtain representative and meaningful results using NATs. Quality assurance and quality control (QA/QC) is emphasized as an important aspect to ensure proper collection, transportation, preservation, and analysis since it forms the basis for interpretation and legislation. Although there are many approaches and methods available for sediment analyses, the scope of the report is limited to sample preparation for (1) analysis of radionuclides (including sediment dating using radionuclides such as Pb-210 and Cs-137) and (2) analysis of trace, minor and major elements using nuclear and related analytical techniques such as NAA, XRF and PIXE.

  8. Adaptation and implementation of the TRACE code for transient analysis in designs lead cooled fast reactors

    International Nuclear Information System (INIS)

    Lazaro, A.; Ammirabile, L.; Martorell, S.

    2015-01-01

    Lead-Cooled Fast Reactor (LFR) has been identified as one of promising future reactor concepts in the technology road map of the Generation IVC International Forum (GIF)as well as in the Deployment Strategy of the European Sustainable Nuclear Industrial Initiative (ESNII), both aiming at improved sustainability, enhanced safety, economic competitiveness, and proliferation resistance. This new nuclear reactor concept requires the development of computational tools to be applied in design and safety assessments to confirm improved inherent and passive safety features of this design. One approach to this issue is to modify the current computational codes developed for the simulation of Light Water Reactors towards their applicability for the new designs. This paper reports on the performed modifications of the TRACE system code to make it applicable to LFR safety assessments. The capabilities of the modified code are demonstrated on series of benchmark exercises performed versus other safety analysis codes. (Author)

  9. Epithermal neutron activation analysis of major and trace elements in Red Sea scleractinian corals

    International Nuclear Information System (INIS)

    Abdo, S.Y.; Sherif, M.M.; Frontasyeva, M.V.

    2017-01-01

    Five corals belonging to common scleractinian reef-building species, and collected from Gulf of Suez, Egypt were subjected to neutron activation analysis. The content of 26 elements: Na, Mg, Cl, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Zn, As, Br, Rb, Sr, Sb, I, Cs, Ba, La, Ce, Gd, Hf, Th, and U was experimentally determined. Ca and Sr have the highest content i.e. 38.4-39.5% and 0.73-0.78% respectively while, the content of all other elements was within the ranges reported for the worldwide corals. For a better understanding of the coral exoskeleton elemental content, the partition coefficient calculated for all determined elements showed a wide range of values varying from 2 × 10 -4 in the case of Cl to 2 × 10 3 for Ce and other insoluble elements. Although all corals were collected in the vicinity of the Port Suez no traces of anthropogenic contamination were evidenced. (author)

  10. Procedure of trace element analysis in oyster tissues by using X-ray fluorescence

    International Nuclear Information System (INIS)

    Vo Thi Tuong Hanh; Dinh Thi Bich Lieu; Dinh Thien Lam and Nguyen Manh Hung

    2004-01-01

    The procedure of trace element analysis such as Ca, Mn, Fe, Zn, Cu, Pb in molluscs (oyster tissues) was established by using X-ray fluorescence techniques. The procedure was investigated from the sample collection, drying, ashing ratio to the analytical techniques by using Cd-109, detector Si (Li) and the peak processing MCAPLUS program was applied for this study. The procedure is based on direct comparison with certified concentrations of international standard reference SRM 1566b Oyster Tissue of National Institute of Standards and Technology, Department of commerce, United States of America for Ca, Mn, Fe, Zn, Cu and the Standard Addition Methods for Pb. The accuracy of the Standard Addition Methods was estimated by CRM281 Rye Grass of Community Bureau of Reference-BCR, European Commission. The results of 10 samples which were collected from several markets in Hanoi are shown. (author)

  11. Study of the trace element content in human cataractous lenses by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Kouris, T.; Theodossiadis, G.; Papadopoulou, C.; Kanias, G.D.; Baikraktari-Kouri, E.

    1986-01-01

    Cataract is a very common disease of the eye lens known since the ancient times. Different mechanisms are responsible for the biogenesis of cataract but the greater number of scientists agree with the theory that cataract formation can be attributed to metabolism disorders in the lens. Instrumental neutron activation analysis has been applied in this work for the determination of the following trace elements: antimony, cobalt, iron, rubidium, selenium and zinc in human lenses with mature cataract. The obtained results are statistically treated and correlated with age and sex of patients. Based on these findings the concentration of each studied element does not have any correlation with the age and/or sex of the patients i.e. when the lens becomes totally opaque. (author)

  12. Neutron activation analysis in forensic investigations. Trace elements characterization of cigarettes

    International Nuclear Information System (INIS)

    Giordani, L.; Rizzio, E.; Brandone, A.

    2005-01-01

    Police investigations of the Italian Ministry of Treasury Police involving the illicit sale of tobacco lead to the confiscation of large quantities of smuggled cigarettes. Thousands of tons of cigarettes of different manufacturers are sequestrated yearly in many regions of Italy and different criminal organizations have been identified as unlawful importers. In order to verify whether the recovered smuggled lots of cigarettes come from the official manufacturers, or they have produced illicitly, usually chemical analysis are carried out. By the determination of trace elements content, specific information can be obtained by comparing different brands of cigarettes and different batches of tobacco. Samples of tobacco of cigarettes manufactured by the Italian State Monopoly, taken as 'reference samples', have been compared with those of illicit origin. Elements such as Co, Br, Cr and Sc have been found to be useful for the selective characterization. The results, submitted to statistical elaboration, provided important information on the origin of smuggled cigarettes. (author)

  13. Integrating Paper Chromatography with Electrochemical Detection for the Trace Analysis of TNT in Soil

    Directory of Open Access Journals (Sweden)

    Patrick Ryan

    2015-07-01

    Full Text Available We report on the development of an electrochemical probe for the trace analysis of 2,4,6-trinitrotoluene (TNT in soil samples. The probe is a combination of graphite electrodes, filter paper, with ethylene glycol and choline chloride as the solvent/electrolyte. Square wave chromatovoltammograms show the probes have a sensitivity for TNT of 0.75 nA/ng and a limit of detection of 100 ng. In addition, by taking advantage of the inherent paper chromatography step, TNT can be separated in both time and cathodic peak potential from 4-amino-dinitrotolene co-spotted on the probe or in soil samples with the presence of methyl parathion as a possible interferent.

  14. Investigation of different types of filters for atmospheric trace elements analysis by three analytical techniques

    International Nuclear Information System (INIS)

    Ali, A.E.; Bacso, J.

    1996-01-01

    Different atmospheric aerosol samples were collected on three types of filters. Disks of both loaded and clean areas of each kind of filter were investigated by XRF, PIXE and Scanning Electron Microscope (SEM) methods. The blank concentration values of the elements Al, Si, P, S, Cl, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Br and Pb in the three types of filters are discussed. It is found that for trace elemental analysis, the Nuclepore membrane filters are the most suitable for sampling. These have much lower blank element concentration values than the glass fibres and ash free filters. It was found also that the PIXE method is a more reliable analytical technique for atmospheric aerosol particles than the other methods. (author). 20 refs., 3 figs., 3 tabs

  15. Radiochemical neutron activation analysis for trace elements evaluation of human milk

    International Nuclear Information System (INIS)

    Gill, K.P.; Zaidi, J.H.; Ahmad, S.

    2003-01-01

    The principal objective pursued in this study is to establish the base-line data on the status of elemental composition in human milk from Pakistani subjects of Rawalpindi/Islamabad area. Radiochemical neutron activation analysis (RNAA) methodology was developed and successfully employed to determine the concentration of 18 minor and trace elements (essential, toxic and nonessential) in human milk. This methodology has significantly improved the detection limits of most of these elements due to suppression of Compton background. The data provide the base-line values of these elements in human milk of low- and medium-income group subjects of the region. The results obtained show good compatibility with the data reported by the WHO on elemental composition of human milk from different geological regions. (orig.)

  16. Analysis of trace elements in scalp hair of mentally retarded children

    International Nuclear Information System (INIS)

    Man, C.K.; Zheng, Y.H.

    2002-01-01

    Hair samples of mildly mentally retarded (LR), moderately mentally retarded (MR), severely mentally retarded (SR) and normal children were collected and measured, using neutron activation analysis and X-ray fluorescence to determine the concentrations of Al, Sb, As, Ca, Cu, I, Fe Pb, Mg, Mn, Hg, K, Sr, S, V and Zn. The groups of children were of ages between 5 and 13. Difference in the mean concentration of each element between groups was tested by Student's t-test. No trend, either decreasing or increasing, has been established as the degree of severity increased from normal to SR children, except for the case of Cu. The present work may shed some light in the interpretation of findings on the effects of trace elements on neurobehavioral functions. (author)

  17. Diode laser based resonance ionization mass spectrometry for spectroscopy and trace analysis of uranium isotopes

    International Nuclear Information System (INIS)

    Hakimi, Amin

    2013-01-01

    In this doctoral thesis, the upgrade and optimization of a diode laser system for high-resolution resonance ionization mass spectrometry is described. A frequency-control system, based on a double-interferometric approach, allowing for absolute stabilization down to 1 MHz as well as frequency detunings of several GHz within a second for up to three lasers in parallel was optimized. This laser system was used for spectroscopic studies on uranium isotopes, yielding precise and unambiguous level energies, total angular momenta, hyperfine constants and isotope shifts. Furthermore, an efficient excitation scheme which can be operated with commercial diode lasers was developed. The performance of the complete laser mass spectrometer was optimized and characterized for the ultra-trace analysis of the uranium isotope 236 U, which serves as a neutron flux dosimeter and tracer for radioactive anthropogenic contaminations in the environment. Using synthetic samples, an isotope selectivity of ( 236 U)/( 238 U) = 4.5(1.5) . 10 -9 was demonstrated.

  18. Statistically sound evaluation of trace element depth profiles by ion beam analysis

    International Nuclear Information System (INIS)

    Schmid, K.; Toussaint, U. von

    2012-01-01

    This paper presents the underlying physics and statistical models that are used in the newly developed program NRADC for fully automated deconvolution of trace level impurity depth profiles from ion beam data. The program applies Bayesian statistics to find the most probable depth profile given ion beam data measured at different energies and angles for a single sample. Limiting the analysis to % level amounts of material allows one to linearize the forward calculation of ion beam data which greatly improves the computation speed. This allows for the first time to apply the maximum likelihood approach to both the fitting of the experimental data and the determination of confidence intervals of the depth profiles for real world applications. The different steps during the automated deconvolution will be exemplified by applying the program to artificial and real experimental data.

  19. Applications of mass spectrometry in the trace element analysis of biological materials

    International Nuclear Information System (INIS)

    Moens, L.

    1997-01-01

    The importance of mass spectrometry for the analysis of biological material is illustrated by reviewing the different mass spectrometric methods applied and describing some typical applications published recently. Though atomic absorption spectrometry is used in the majority of analyses of biological material, most mass spectrometric methods have been used to some extent for trace element determination in biomedical research. The relative importance of the different methods is estimated by reviewing recent research papers. It is striking that especially inductively coupled plasma mass spectrometry is increasingly being applied, partly because the method can be used on-line after chromatographic separation, in speciation studies. Mass spectrometric methods prove to offer unique possibilities in stable isotope tracer studies and for this purpose also experimentally demanding methods such as thermal ionization mass spectrometry and accelerator mass spectrometry are frequently used. (orig.)

  20. Trace and surface analysis of ceramic layers of solid oxide fuel cells by mass spectrometry.

    Science.gov (United States)

    Becker, J S; Breuer, U; Westheide, J; Saprykin, A I; Holzbrecher, H; Nickel, H; Dietze, H J

    1996-06-01

    For the trace analysis of impurities in thick ceramic layers of a solid oxide fuel cell (SOFC) sensitive solid-state mass spectrometric methods, such as laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and radiofrequency glow discharge mass spectrometry (rf-GDMS) have been developed and used. In order to quantify the analytical results of LA-ICP-MS, the relative sensitivity coefficients of elements in a La(0.6)Sr(0.35)MnO(3) matrix have been determined using synthetic standards. Secondary ion mass spectrometry (SIMS) - as a surface analytical method - has been used to characterize the element distribution and diffusion profiles of matrix elements on the interface of a perovskite/Y-stabilized ZrO(2) layer. The application of different mass spectrometric methods for process control in the preparation of ceramic layers for the SOFC is described.