WorldWideScience

Sample records for environmental surface samples

  1. Rapid extraction and assay of uranium from environmental surface samples

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Christopher A.; Chouyyok, Wilaiwan; Speakman, Robert J.; Olsen, Khris B.; Addleman, Raymond Shane

    2017-10-01

    Extraction methods enabling faster removal and concentration of uranium compounds for improved trace and low-level assay are demonstrated for standard surface sampling material in support of nuclear safeguards efforts, health monitoring, and other nuclear analysis applications. A key problem with the existing surface sampling swipes is the requirement for complete digestion of sample and sampling matrix. This is a time-consuming and labour-intensive process that limits laboratory throughput, elevates costs, and increases background levels. Various extraction methods are explored for their potential to quickly and efficiently remove different chemical forms of uranium from standard surface sampling material. A combination of carbonate and peroxide solutions is shown to give the most rapid and complete form of uranyl compound extraction and dissolution. This rapid extraction process is demonstrated to be compatible with standard inductive coupled plasma mass spectrometry methods for uranium isotopic assay as well as screening techniques such as x-ray fluorescence. The general approach described has application beyond uranium to other analytes of nuclear forensic interest (e.g., rare earth elements and plutonium) as well as heavy metals for environmental and industrial hygiene monitoring.

  2. Environmental sampling

    International Nuclear Information System (INIS)

    Puckett, J.M.

    1998-01-01

    Environmental Sampling (ES) is a technology option that can have application in transparency in nuclear nonproliferation. The basic process is to take a sample from the environment, e.g., soil, water, vegetation, or dust and debris from a surface, and through very careful sample preparation and analysis, determine the types, elemental concentration, and isotopic composition of actinides in the sample. The sample is prepared and the analysis performed in a clean chemistry laboratory (CCL). This ES capability is part of the IAEA Strengthened Safeguards System. Such a Laboratory is planned to be built by JAERI at Tokai and will give Japan an intrinsic ES capability. This paper presents options for the use of ES as a transparency measure for nuclear nonproliferation

  3. Storage Effects on Sample Integrity of Environmental Surface Sampling Specimens with Bacillus anthracis Spores.

    Science.gov (United States)

    Perry, K Allison; O'Connell, Heather A; Rose, Laura J; Noble-Wang, Judith A; Arduino, Matthew J

    The effect of packaging, shipping temperatures and storage times on recovery of Bacillus anthracis . Sterne spores from swabs was investigated. Macrofoam swabs were pre-moistened, inoculated with Bacillus anthracis spores, and packaged in primary containment or secondary containment before storage at -15°C, 5°C, 21°C, or 35°C for 0-7 days. Swabs were processed according to validated Centers for Disease Control/Laboratory Response Network culture protocols, and the percent recovery relative to a reference sample (T 0 ) was determined for each variable. No differences were observed in recovery between swabs held at -15° and 5°C, (p ≥ 0.23). These two temperatures provided significantly better recovery than swabs held at 21°C or 35°C (all 7 days pooled, p ≤ 0.04). The percent recovery at 5°C was not significantly different if processed on days 1, 2 or 4, but was significantly lower on day 7 (day 2 vs. 7, 5°C, 10 2 , p=0.03). Secondary containment provided significantly better percent recovery than primary containment, regardless of storage time (5°C data, p ≤ 0.008). The integrity of environmental swab samples containing Bacillus anthracis spores shipped in secondary containment was maintained when stored at -15°C or 5°C and processed within 4 days to yield the optimum percent recovery of spores.

  4. Sampling methods for recovery of human enteric viruses from environmental surfaces.

    Science.gov (United States)

    Turnage, Nicole L; Gibson, Kristen E

    2017-10-01

    Acute gastroenteritis causes the second highest infectious disease burden worldwide. Human enteric viruses have been identified as leading causative agents of acute gastroenteritis as well as foodborne illnesses in the U.S. and are generally transmitted by fecal-oral contamination. There is growing evidence of transmission occurring via contaminated fomite including food contact surfaces. Additionally, human enteric viruses have been shown to remain infectious on fomites over prolonged periods of time. To better understand viral persistence, there is a need for more studies to investigate this phenomenon. Therefore, optimization of surface sampling methods is essential to aid in understanding environmental contamination to ensure proper preventative measures are being applied. In general, surface sampling studies are limited and highly variable among recovery efficiencies and research parameters used (e.g., virus type/density, surface type, elution buffers, tools). This review aims to discuss the various factors impacting surface sampling of viruses from fomites and to explore how researchers could move towards a more sensitive and standard sampling method. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Surface-enhanced Raman scattering detection of silver nanoparticles in environmental and biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Huiyuan [Stockbridge School of Agriculture, University of Massachusetts, Amherst, MA 01003 (United States); Xing, Baoshan, E-mail: bx@umass.edu [Stockbridge School of Agriculture, University of Massachusetts, Amherst, MA 01003 (United States); Hamlet, Leigh C.; Chica, Andrea [Stockbridge School of Agriculture, University of Massachusetts, Amherst, MA 01003 (United States); He, Lili, E-mail: lilihe@foodsci.umass.edu [Department of Food Science, University of Massachusetts, Amherst, MA 01003 (United States)

    2016-06-01

    Growing concerns over the potential release and threat of silver nanoparticles (AgNPs) to environmental and biological systems urge researchers to investigate their fate and behavior. However, current analytical techniques cannot meet the requirements for rapidly, sensitively and reliably probing AgNPs in complex matrices. Surface-enhanced Raman spectroscopy (SERS) has shown great capability for rapid detection of AgNPs based on an indicator molecule that can bind on the AgNP surface. The objective of this study was to exploit SERS to detect AgNPs in environmental and biological samples through optimizing the Raman indicator for SERS. Seven indicator molecules were selected and determined to obtain their SERS signals at optimal concentrations. Among them, 1,2-di(4-pyridyl)ethylene (BPE), crystal violet and ferric dimethyl-dithiocarbamate (ferbam) produced the highest SERS intensities. Further experiments on binding competition between each two of the three candidates showed that ferbam had the highest AgNPs-binding ability. The underlying mechanism lies in the strong binding affinity of ferbam with AgNPs via multiple sulfur atoms. We further validated ferbam to be an effective indicator for SERS detection of as low as 0.1 mg/L AgNPs in genuine surface water and 0.57 mg/L in spinach juice. Moreover, limited interference on SERS detection of AgNPs was found from environmentally relevant inorganic ions, organic matter, inorganic particles, as well as biologically relevant components, demonstrating the ferbam-assisted SERS is an effective and sensitive method to detect AgNPs in complex environmental and biological samples. - Graphical abstract: SERS signal intensity of ferbam indicates the concentration of AgNPs. - Highlights: • Ferbam was found to be the best indicator for SERS detection of AgNPs. • SERS was able to detect AgNPs in both environmental and biological samples. • Major components in the two matrices had limited effect on AgNP detection.

  6. Surface-enhanced Raman scattering detection of silver nanoparticles in environmental and biological samples

    International Nuclear Information System (INIS)

    Guo, Huiyuan; Xing, Baoshan; Hamlet, Leigh C.; Chica, Andrea; He, Lili

    2016-01-01

    Growing concerns over the potential release and threat of silver nanoparticles (AgNPs) to environmental and biological systems urge researchers to investigate their fate and behavior. However, current analytical techniques cannot meet the requirements for rapidly, sensitively and reliably probing AgNPs in complex matrices. Surface-enhanced Raman spectroscopy (SERS) has shown great capability for rapid detection of AgNPs based on an indicator molecule that can bind on the AgNP surface. The objective of this study was to exploit SERS to detect AgNPs in environmental and biological samples through optimizing the Raman indicator for SERS. Seven indicator molecules were selected and determined to obtain their SERS signals at optimal concentrations. Among them, 1,2-di(4-pyridyl)ethylene (BPE), crystal violet and ferric dimethyl-dithiocarbamate (ferbam) produced the highest SERS intensities. Further experiments on binding competition between each two of the three candidates showed that ferbam had the highest AgNPs-binding ability. The underlying mechanism lies in the strong binding affinity of ferbam with AgNPs via multiple sulfur atoms. We further validated ferbam to be an effective indicator for SERS detection of as low as 0.1 mg/L AgNPs in genuine surface water and 0.57 mg/L in spinach juice. Moreover, limited interference on SERS detection of AgNPs was found from environmentally relevant inorganic ions, organic matter, inorganic particles, as well as biologically relevant components, demonstrating the ferbam-assisted SERS is an effective and sensitive method to detect AgNPs in complex environmental and biological samples. - Graphical abstract: SERS signal intensity of ferbam indicates the concentration of AgNPs. - Highlights: • Ferbam was found to be the best indicator for SERS detection of AgNPs. • SERS was able to detect AgNPs in both environmental and biological samples. • Major components in the two matrices had limited effect on AgNP detection.

  7. Surface-enhanced Raman spectroscopy for uranium detection and analysis in environmental samples

    International Nuclear Information System (INIS)

    Ruan Chuanmin; Luo Wensui; Wang Wei; Gu Baohua

    2007-01-01

    Techniques for rapid screening of uranium in environmental samples are needed, and this study entails the development of surface-enhanced Raman scattering (SERS) for analyzing uranium in aqueous media with improved sensitivity and reproducibility. A new SERS substrate based on (aminomethyl)phosphonic acid (APA)-modified gold nanoparticles was found to give greater than three orders of magnitude SERS enhancement compared with unmodified bare gold nanoparticles. Intensities of uranyl band at about 830 cm -1 were proportional to the concentrations of uranium in solution, especially at relatively low concentrations ( -5 M). A detection limit of ∼8 x 10 -7 M was achieved with a good reproducibility since the measurement was performed directly in dispersed aqueous suspension. Without pretreatment, the technique was successfully employed for detecting uranium in a highly contaminated groundwater with a low pH, high dissolved salts (e.g., nitrate, sulfate, calcium and aluminum) and total organic carbon

  8. Surface-Enhanced Raman Spectroscopy for Uranium Detection and Analysis in Environmental Samples

    International Nuclear Information System (INIS)

    Ruan, Chuanmin; Luo, Wensui; Wang, Wei; Gu, Baohua

    2007-01-01

    Techniques for rapid screening of uranium in environmental samples are needed, and this study entails the development of surface-enhanced Raman scattering (SERS) for analyzing uranium in aqueous media with improved sensitivity and reproducibility. A new SERS substrate based on (aminomethyl)phosphonic acid (APA)-modified gold nanoparticles was found to give greater than three orders of magnitude SERS enhancement compared with unmodified bare gold nanoparticles. Intensities of uranyl band at about 830 cm-1 were proportional to the concentrations of uranium in solution, especially at relatively low concentrations (<10-5 M). A detection limit of ∼8 e10-7 M was achieved with a good reproducibility since the measurement was performed directly in dispersed aqueous suspension. Without pretreatment, the technique was successfully employed for the detection of uranium in a highly contaminated groundwater with a low pH, high dissolved salts (e.g., nitrate, sulfate, calcium and aluminum) and total organic carbon

  9. Radioactivity in environmental samples

    International Nuclear Information System (INIS)

    Fornaro, Laura

    2001-01-01

    The objective of this practical work is to familiarize the student with radioactivity measures in environmental samples. For that were chosen samples a salt of natural potassium, a salt of uranium or torio and a sample of drinkable water

  10. Development of a One-Handed, Environmental Surface-Sampling Device

    Science.gov (United States)

    2016-05-01

    individual packaging, an operator can generate a large amount of waste that needs to be managed during a sampling mission. The U.S. Army Edgewood...prepared and spore spotting was performed in a biological safety cabinet. For the spore- spotting procedures, the surfaces were spotted with 1 mL of...260 nm (A260) and 280 nm (A280). To determine the DNA concentration for each sample, the NanoDrop software used a modified Beer –Lambert equation and

  11. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1993-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). Samples are routinely collected and analyzed to determine the quality of air, surface water, ground water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Drinking Water Project, and Ground-Water Surveillance Project.

  12. Area G perimeter surface-soil and single-stage water sampling: Environmental surveillance for fiscal year 1993

    International Nuclear Information System (INIS)

    Conrad, R.; Childs, M.; Rivera-Dirks, C.; Coriz, F.

    1995-07-01

    Area G, in Technical Area 54, has been the principle facility at Los Alamos National Laboratory for the storage and disposal of low-level and transuranic (TRU) radioactive wastes since 1957. The current environmental investigation consisted of ESH-19 personnel who collected soil and single-stage water samples around the perimeter of Area G to characterize possible contaminant movement through surface-water runoff. These samples were analyzed for tritium, total uranium, isotopic plutonium, americium-241 (soil only), and cesium 137. The metals, mercury, lead, and barium, were analyzed using x-ray fluorescence

  13. Surface water sampling and analysis plan for environmental monitoring in Waste Area Grouping 6 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    This Sampling and Analysis Plan addresses surface water monitoring, sampling, and analysis activities that will be conducted in support of the Environmental Monitoring Plan for Waste Area Grouping (WAG) 6. WAG 6 is a shallow-burial land disposal facility for low-level radioactive waste at the Oak Ridge National Laboratory, a research facility owned by the US Department of Energy and managed by Martin Marietta Energy Systems, Inc. Surface water monitoring will be conducted at nine sites within WAG 6. Activities to be conducted will include the installation, inspection, and maintenance of automatic flow-monitoring and sampling equipment and manual collection of various water and sediment samples. The samples will be analyzed for various organic, inorganic, and radiological parameters. The information derived from the surface water monitoring, sampling, and analysis will aid in evaluating risk associated with contaminants migrating off-WAG, and will be used in calculations to establish relationships between contaminant concentration (C) and flow (Q). The C-Q relationship will be used in calculating the cumulative risk associated with the off-WAG migration of contaminants.

  14. Surface water sampling and analysis plan for environmental monitoring in Waste Area Grouping 6 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program

    International Nuclear Information System (INIS)

    1994-06-01

    This Sampling and Analysis Plan addresses surface water monitoring, sampling, and analysis activities that will be conducted in support of the Environmental Monitoring Plan for Waste Area Grouping (WAG) 6. WAG 6 is a shallow-burial land disposal facility for low-level radioactive waste at the Oak Ridge National Laboratory, a research facility owned by the US Department of Energy and managed by Martin Marietta Energy Systems, Inc. Surface water monitoring will be conducted at nine sites within WAG 6. Activities to be conducted will include the installation, inspection, and maintenance of automatic flow-monitoring and sampling equipment and manual collection of various water and sediment samples. The samples will be analyzed for various organic, inorganic, and radiological parameters. The information derived from the surface water monitoring, sampling, and analysis will aid in evaluating risk associated with contaminants migrating off-WAG, and will be used in calculations to establish relationships between contaminant concentration (C) and flow (Q). The C-Q relationship will be used in calculating the cumulative risk associated with the off-WAG migration of contaminants

  15. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1997-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL)(a) for the US Department of Energy (DOE). This document contains the planned 1997 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. In addition, Section 3.0, Biota, also reflects a rotating collection schedule identifying the year a specific sample is scheduled for collection. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, General Environmental Protection Program, and DOE Order 5400.5, Radiation Protection of the Public and the Environment. The sampling methods will be the same as those described in the Environmental Monitoring Plan, US Department of Energy, Richland Operations Office, DOE/RL91-50, Rev. 1, US Department of Energy, Richland, Washington

  16. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1995-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring onsite drinking water falls outside the scope of the SESP. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control, and reporting. The ground-water sampling schedule identifies ground-water sampling .events used by PNL for environmental surveillance of the Hanford Site. Sampling is indicated as annual, semi-annual, quarterly, or monthly in the sampling schedule. Some samples are collected and analyzed as part of ground-water monitoring and characterization programs at Hanford (e.g. Resources Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or Operational). The number of samples planned by other programs are identified in the sampling schedule by a number in the analysis column and a project designation in the Cosample column. Well sampling events may be merged to avoid redundancy in cases where sampling is planned by both-environmental surveillance and another program

  17. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1995-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring onsite drinking water falls outside the scope of the SESP. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control, and reporting. The ground-water sampling schedule identifies ground-water sampling .events used by PNL for environmental surveillance of the Hanford Site. Sampling is indicated as annual, semi-annual, quarterly, or monthly in the sampling schedule. Some samples are collected and analyzed as part of ground-water monitoring and characterization programs at Hanford (e.g. Resources Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or Operational). The number of samples planned by other programs are identified in the sampling schedule by a number in the analysis column and a project designation in the Cosample column. Well sampling events may be merged to avoid redundancy in cases where sampling is planned by both-environmental surveillance and another program.

  18. Surface Environmental Surveillance Procedures Manual

    International Nuclear Information System (INIS)

    Hanf, Robert W.; Poston, Ted M.

    2000-01-01

    Shows and explains certain procedures needed for surface environmental surveillance. Hanford Site environmental surveillance is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) under the Surface Environmental Surveillance Project (SESP). The basic requirements for site surveillance are set fourth in DOE Order 5400.1, General Environmental Protection Program Requirements. Guidance for the SESP is provided in DOE Order 5484.1, Environmental Protection, Safety, and Health Protection Information Reporting Requirements and DOE Order 5400.5, Radiation Protection of the Public and Environment. Guidelines for environmental surveillance activities are provided in DOE/EH-0173T, Environmental Regulatory Guide for Radiological Effluent Monitoring and Environmental Surveillance. An environmental monitoring plan for the Hanford Site is outlined in DOE/RL 91-50 Rev. 2, Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office. Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual. Personnel training requirements are documented in SESP-TP-01 Rev.2, Surface Environmental Surveillance Project Training Program.

  19. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1994-02-01

    This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of the onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site

  20. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1994-02-01

    This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of the onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site.

  1. Soil sampling for environmental contaminants

    International Nuclear Information System (INIS)

    2004-10-01

    The Consultants Meeting on Sampling Strategies, Sampling and Storage of Soil for Environmental Monitoring of Contaminants was organized by the International Atomic Energy Agency to evaluate methods for soil sampling in radionuclide monitoring and heavy metal surveys for identification of punctual contamination (hot particles) in large area surveys and screening experiments. A group of experts was invited by the IAEA to discuss and recommend methods for representative soil sampling for different kinds of environmental issues. The ultimate sinks for all kinds of contaminants dispersed within the natural environment through human activities are sediment and soil. Soil is a particularly difficult matrix for environmental pollution studies as it is generally composed of a multitude of geological and biological materials resulting from weathering and degradation, including particles of different sizes with varying surface and chemical properties. There are so many different soil types categorized according to their content of biological matter, from sandy soils to loam and peat soils, which make analytical characterization even more complicated. Soil sampling for environmental monitoring of pollutants, therefore, is still a matter of debate in the community of soil, environmental and analytical sciences. The scope of the consultants meeting included evaluating existing techniques with regard to their practicability, reliability and applicability to different purposes, developing strategies of representative soil sampling for cases not yet considered by current techniques and recommending validated techniques applicable to laboratories in developing Member States. This TECDOC includes a critical survey of existing approaches and their feasibility to be applied in developing countries. The report is valuable for radioanalytical laboratories in Member States. It would assist them in quality control and accreditation process

  2. Sampling and chemical analysis in environmental samples around Nuclear Power Plants and some environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Woo; Han, Man Jung; Cho, Seong Won; Cho, Hong Jun; Oh, Hyeon Kyun; Lee, Jeong Min; Chang, Jae Sook [KORTIC, Taejon (Korea, Republic of)

    2002-12-15

    Twelve kinds of environmental samples such as soil, seawater, underground water, etc. around Nuclear Power Plants(NPPs) were collected. Tritium chemical analysis was tried for the samples of rain water, pine-needle, air, seawater, underground water, chinese cabbage, a grain of rice and milk sampled around NPPs, and surface seawater and rain water sampled over the country. Strontium in the soil that sere sampled at 60 point of district in Korea were analyzed. Tritium were sampled at 60 point of district in Korea were analyzed. Tritium were analyzed in 21 samples of surface seawater around the Korea peninsular that were supplied from KFRDI(National Fisheries Research and Development Institute). Sampling and chemical analysis environmental samples around Kori, Woolsung, Youngkwang, Wooljin Npps and Taeduk science town for tritium and strontium analysis was managed according to plans. Succeed to KINS after all samples were tried.

  3. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1991-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. The routine sampling plan for the SESP has been revised this year to reflect changing site operations and priorities. Some sampling previously performed at least annually has been reduced in frequency, and some new sampling to be performed at a less than annual frequency has been added. Therefore, the SESP schedule reflects sampling to be conducted in calendar year 1991 as well as future years. The ground-water sampling schedule is for 1991. This schedule is subject to modification during the year in response to changes in Site operation, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford evirons

  4. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1991-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. The routine sampling plan for the SESP has been revised this year to reflect changing site operations and priorities. Some sampling previously performed at least annually has been reduced in frequency, and some new sampling to be performed at a less than annual frequency has been added. Therefore, the SESP schedule reflects sampling to be conducted in calendar year 1991 as well as future years. The ground-water sampling schedule is for 1991. This schedule is subject to modification during the year in response to changes in Site operation, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford evirons.

  5. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L E

    1992-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. Samples for radiological analyses include Air-Particulate Filter, gases and vapor; Water/Columbia River, Onsite Pond, Spring, Irrigation, and Drinking; Foodstuffs/Animal Products including Whole Milk, Poultry and Eggs, and Beef; Foodstuffs/Produce including Leafy Vegetables, Vegetables, and Fruit; Foodstuffs/Farm Products including Wine, Wheat and Alfalfa; Wildlife; Soil; Vegetation; and Sediment. Direct Radiation Measurements include Terrestrial Locations, Columbia River Shoreline Locations, and Onsite Roadway, Railway and Aerial, Radiation Surveys.

  6. Area G perimeter surface-soil and single-stage water sampling. Environmental surveillance for fiscal year 95. Progress report

    International Nuclear Information System (INIS)

    Childs, M.; Conrad, R.

    1997-09-01

    ESH-19 personnel collected soil and single-stage water samples around the perimeter of Area G at Los Alamos National Laboratory (LANL) during FY 95 to characterize possible radionuclide movement out of Area G through surface water and entrained sediment runoff. Soil samples were analyzed for tritium, total uranium, isotopic plutonium, americium-241, and cesium-137. The single-stage water samples were analyzed for tritium and plutonium isotopes. All radiochemical data was compared with analogous samples collected during FY 93 and 94 and reported in LA-12986 and LA-13165-PR. Six surface soils were also submitted for metal analyses. These data were included with similar data generated for soil samples collected during FY 94 and compared with metals in background samples collected at the Area G expansion area

  7. Hanford Site surface environmental surveillance

    International Nuclear Information System (INIS)

    Dirkes, R.L.

    1998-01-01

    Environmental surveillance of the Hanford Site and the surrounding region is conducted to demonstrate compliance with environmental regulations, confirm adherence to US Department of Energy (DOE) environmental protection policies, support DOE environmental management decisions, and provide information to the public. The Surface Environmental Surveillance Project (SESP) is a multimedia environmental monitoring program conducted to measure the concentrations of radionuclides and chemical contaminants in the environment and assess the integrated effects of these contaminants on the environment and the public. The monitoring program includes sampling air, surface water, sediments, soil, natural vegetation, agricultural products, fish, and wildlife. Functional elements inherent in the operation of the SESP include project management, quality assurance/control, training, records management, environmental sampling network design and implementation, sample collection, sample analysis, data management, data review and evaluation, exposure assessment, and reporting. The SESP focuses on those contaminant/media combinations calculated to have the highest potential for contributing to off-site exposure. Results of the SESP indicate that contaminant concentrations in the Hanford environs are very low, generally below environmental standards, at or below analytical detection levels, and indicative of environmental levels. However, areas of elevated contaminant concentrations have been identified at Hanford. The extent of these areas is generally limited to past operating areas and waste disposal sites

  8. Subsurface seeding of surface harmful algal blooms observed through the integration of autonomous gliders, moored environmental sample processors, and satellite remote sensing in southern California

    KAUST Repository

    Seegers, Bridget N.

    2015-04-01

    An observational study was performed in the central Southern California Bight in Spring 2010 to understand the relationship between seasonal spring phytoplankton blooms and coastal processes that included nutrient input from upwelling, wastewater effluent plumes, and other processes. Multi-month Webb Slocum glider deployments combined with MBARI environmental sample processors (ESPs), weekly pier sampling, and ocean color data provided a multidimensional characterization of the development and evolution of harmful algal blooms (HABs). Results from the glider and ESP observations demonstrated that blooms of toxic Pseudo-nitzschia sp. can develop offshore and subsurface prior to their manifestation in the surface layer and/or near the coast. A significant outbreak and surface manifestation of the blooms coincided with periods of upwelling, or other processes that caused shallowing of the pycnocline and subsurface chlorophyll maximum. Our results indicate that subsurface populations can be an important source for “seeding” surface Pseudo-nitzschia HAB events in southern California.

  9. Micropore-free surface-activated carbon for the analysis of polychlorinated dibenzo-p-dioxins-dibenzofurans and non-ortho-substituted polychlorinated biphenyls in environmental samples.

    Science.gov (United States)

    Kemmochi, Yukio; Tsutsumi, Kaori; Arikawa, Akihiro; Nakazawa, Hiroyuki

    2002-11-22

    2,3,7,8-Substituted polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDD/Fs) and non-ortho-substituted polychlorinated biphenyls (PCBs) account for almost all of the total toxic equivalents (TEQ) in environmental samples. Activated carbon columns are used to fractionate the samples for GC-MS analysis or bioassay. Micropore-free surface-activated carbon is highly selective for PCDD/Fs and non-ortho-PCBs and can improve the conventional activated carbon column clean-up. Along with sulfuric acid-coated diatomaceous earth columns, micropore-free surface-activated carbon provides a rapid, robust, and high-throughput sample preparation method for PCDD/Fs and non-ortho-PCBs analysis.

  10. Mars Surface Environmental Issues

    Science.gov (United States)

    Charles, John

    2002-01-01

    Planetary exploration by astronauts will require extended periods of habitation on a planet's surface, under the influence of environmental factors that are different from those of Earth and the spacecraft that delivered the crew to the planet. Human exploration of Mars, a possible near-term planetary objective, can be considered a challenging scenario. Mission scenarios currently under consideration call for surface habitation periods of from 1 to 18 months on even the earliest expeditions. Methods: Environmental issues associated with Mars exploration have been investigated by NASA and the National Space Biomedical Research Institute (NSBRI) as part of the Bioastronautics Critical Path Roadmap Project (see http ://criticalpath.jsc.nasa.gov). Results: Arrival on Mars will immediately expose the crew to gravity only 38% of that at Earth's surface in possibly the first prolonged exposure to gravity other than the 1G of Earth's surface and the zero G of weightless space flight, with yet unknown effects on crew physiology. The radiation at Mars' surface is not well documented, although the planet's bulk and even its thin atmosphere may moderate the influx of galactic cosmic radiation and energetic protons from solar flares. Secondary radiation from activated components of the soil must also be considered. Ultrafine and larger respirable and nonrespirable particles in Martian dust introduced into the habitat after surface excursions may induce pulmonary inflammation exacerbated by the additive reactive and oxidizing nature of the dust. Stringent decontamination cannot eliminate mechanical and corrosive effects of the dust on pressure suits and exposed machinery. The biohazard potential of putative indigenous Martian microorganisms may be assessed by comparison with analog environments on Earth. Even in their absence, human microorganisms, if not properly controlled, can be a threat to the crew's health. Conclusions: Mars' surface offers a substantial challenge to the

  11. Environmental sampling for trace analysis

    International Nuclear Information System (INIS)

    Markert, B.

    1994-01-01

    Often too little attention is given to the sampling before and after actual instrumental measurement. This leads to errors, despite increasingly sensitive analytical systems. This is one of the first books to pay proper attention to representative sampling. It offers an overview of the most common techniques used today for taking environmental samples. The techniques are clearly presented, yield accurate and reproducible results and can be used to sample -air - water - soil and sediments - plants and animals. A comprehensive handbook, this volume provides an excellent starting point for researchers in the rapidly expanding field of environmental analysis. (orig.)

  12. Hanford site environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1998-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1 open-quotes General Environmental Protection Program,close quotes and DOE Order 5400.5, open-quotes Radiation Protection of the Public and the Environment.close quotes The sampling methods are described in the Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office, DOE/RL91-50, Rev. 2, U.S. Department of Energy, Richland, Washington. This document contains the 1998 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section of this document describes the planned sampling schedule for a specific media (air, surface water, biota, soil and vegetation, sediment, and external radiation). Each section includes the sample location, sample type, and analyses to be performed on the sample. In some cases, samples are scheduled on a rotating basis and may not be planned for 1998 in which case the anticipated year for collection is provided. In addition, a map is included for each media showing sample locations

  13. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    RW Hanf; TM Poston

    2000-09-20

    Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual.

  14. Hanford Site Environmental Surveillance Master Sampling Schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1999-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, ''General Environmental protection Program,'' and DOE Order 5400.5, ''Radiation Protection of the Public and the Environment.'' The sampling methods are described in the Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office, DOE/RL-91-50, Rev.2, U.S. Department of Energy, Richland, Washington. This document contains the CY1999 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes the sampling location, sample type, and analyses to be performed on the sample. In some cases, samples are scheduled on a rotating basis and may not be collected in 1999 in which case the anticipated year for collection is provided. In addition, a map is included for each media showing approximate sampling locations

  15. A Improved Seabed Surface Sand Sampling Device

    Science.gov (United States)

    Luo, X.

    2017-12-01

    In marine geology research it is necessary to obtain a suf fcient quantity of seabed surface samples, while also en- suring that the samples are in their original state. Currently,there are a number of seabed surface sampling devices available, but we fnd it is very diffcult to obtain sand samples using these devices, particularly when dealing with fne sand. Machine-controlled seabed surface sampling devices are also available, but generally unable to dive into deeper regions of water. To obtain larger quantities of seabed surface sand samples in their original states, many researchers have tried to improve upon sampling devices,but these efforts have generally produced ambiguous results, in our opinion.To resolve this issue, we have designed an improved andhighly effective seabed surface sand sampling device that incorporates the strengths of a variety of sampling devices. It is capable of diving into deepwater to obtain fne sand samples and is also suited for use in streams, rivers, lakes and seas with varying levels of depth (up to 100 m). This device can be used for geological mapping, underwater prospecting, geological engineering and ecological, environmental studies in both marine and terrestrial waters.

  16. Subsurface seeding of surface harmful algal blooms observed through the integration of autonomous gliders, moored environmental sample processors, and satellite remote sensing in southern California

    KAUST Repository

    Seegers, Bridget N.; Birch, James M.; Marin, Roman; Scholin, Chris A.; Caron, David A.; Seubert, Erica L.; Howard, Meredith D. A.; Robertson, George L.; Jones, Burton

    2015-01-01

    effluent plumes, and other processes. Multi-month Webb Slocum glider deployments combined with MBARI environmental sample processors (ESPs), weekly pier sampling, and ocean color data provided a multidimensional characterization of the development

  17. Hanford Site Environmental Surveillance Master Sampling Schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    2000-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, General Environmental Protection Program: and DOE Order 5400.5, Radiation Protection of the Public and the Environment. The sampling design is described in the Operations Office, Environmental Monitoring Plan, United States Department of Energy, Richland DOE/RL-91-50, Rev.2, U.S. Department of Energy, Richland, Washington. This document contains the CY 2000 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes sampling locations, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2000 in which case the anticipated year for collection is provided. In addition, a map showing approximate sampling locations is included for each media scheduled for collection

  18. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Hanf, RW; Dirkes, RL

    1990-02-01

    This manual establishes the procedures for the collection of environmental samples and the performance of radiation surveys and other field measurements. Responsibilities are defined for those personnel directly involved in the collection of samples and the performance of field measurements.

  19. Ball assisted device for analytical surface sampling

    Science.gov (United States)

    ElNaggar, Mariam S; Van Berkel, Gary J; Covey, Thomas R

    2015-11-03

    A system for sampling a surface includes a sampling probe having a housing and a socket, and a rolling sampling sphere within the socket. The housing has a sampling fluid supply conduit and a sampling fluid exhaust conduit. The sampling fluid supply conduit supplies sampling fluid to the sampling sphere. The sampling fluid exhaust conduit has an inlet opening for receiving sampling fluid carried from the surface by the sampling sphere. A surface sampling probe and a method for sampling a surface are also disclosed.

  20. Area G perimeter surface-soil and single-stage water sampling: Environmental surveillance for fiscal year 94, Group ESH-19. Progress report

    International Nuclear Information System (INIS)

    Conrad, R.; Childs, M.; Lyons, C.R.; Coriz, F.

    1996-08-01

    ESH-19 personnel collected soil and single-stage water samples around the perimeter of Area G at Los Alamos National Laboratory during FY94 to characterize possible contaminant movement out of Area G through surface-water and sediment runoff. These samples were analyzed for tritium, total uranium, isotopic plutonium, americium-241, and cesium-137. Ten metals were also analyzed on selected soils using analytical laboratory techniques. All radiochemical data are compared with analogous samples collected during FY 93 and reported in LA-12986. Baseline concentrations for future disposal operations were established for metals and radionuclides by a sampling program in the proposed Area G Expansion Area. Considering the amount of radioactive waste that has been disposed at Area G, there is evidence of only low concentrations of radionuclides on perimeter surface soils. Consequently, little radioactivity is leaving the confines of Area G via the surface water runoff pathway

  1. Fallout Concentration Various Environmental Samples in Indonesia

    International Nuclear Information System (INIS)

    Sutarman

    2001-01-01

    The testing of nuclear weapons have been carried out by the advanced countries, such as United States, Russian Federation, United Kingdom, France, China, India and Pakistan, since about 1945 until 1998. Nuclear weapons tests were conducted at various locations, on and above the earth's surface or underground or on and under the ocean's surface. Nuclear explosions caused the radionuclides of fission product, such as 131 l, 89 Sr, 90 Sr, 134 Cs, 137 Cs, and 239 Pu released to the atmospheric layer. In the atmospheric layer, the long-lived radionuclides, i.e, 90 Sr dan 137 Cs will be distributed into the environment as the fallout radionuclides, and deposited in the various environmental samples (soil, water, and biota). In general, at several locations in Indonesia the 90 Sr and 137 Cs in the various environmental samples still can be detected. The data of measurement results of 90 Sr and 137 Cs concentrations were generally lower than that from some countries in the northern hemisphere. (author)

  2. Surface engineering and environmental issues

    International Nuclear Information System (INIS)

    Aguero, A.

    2007-01-01

    Surface engineering addresses the modification of the microstructure and/or composition of the surface of components by mechanical, physical or chemical methods that may imply adding a material in order to change the surface properties of said components. One of its most important consequences is the significant increase of the useful life of a variety of components in a large number of industrial applications. Moreover, it contributes to energy savings by increasing efficiencies as it allows higher combustion temperatures, by allowing the use of lighter components and by significant friction reduction. In this paper, surface engineering is introduced, as well as its different modalities, examples of industrial applications and positive and negative environmental impacts. (Author) 29 refs

  3. Sampling method of environmental radioactivity monitoring

    International Nuclear Information System (INIS)

    1984-01-01

    This manual provides sampling methods of environmental samples of airborne dust, precipitated dust, precipitated water (rain or snow), fresh water, soil, river sediment or lake sediment, discharged water from a nuclear facility, grains, tea, milk, pasture grass, limnetic organisms, daily diet, index organisms, sea water, marine sediment, marine organisms, and that for tritium and radioiodine determination for radiation monitoring from radioactive fallout or radioactivity release by nuclear facilities. This manual aims at the presentation of standard sampling procedures for environmental radioactivity monitoring regardless of monitoring objectives, and shows preservation method of environmental samples acquired at the samplingpoint for radiation counting for those except human body. Sampling techniques adopted in this manual is decided by the criteria that they are suitable for routine monitoring and any special skillfulness is not necessary. Based on the above-mentioned principle, this manual presents outline and aims of sampling, sampling position or object, sampling quantity, apparatus, equipment or vessel for sampling, sampling location, sampling procedures, pretreatment and preparation procedures of a sample for radiation counting, necessary recording items for sampling and sample transportation procedures. Special attention is described in the chapter of tritium and radioiodine because these radionuclides might be lost by the above-mentioned sample preservation method for radiation counting of less volatile radionuclides than tritium or radioiodine. (Takagi, S.)

  4. Isotope dilution analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.; Lesny, J.; Korenova, Z.; Klas, J.; Klehr, E.H.

    1986-01-01

    Isotope dilution analysis has been used for the determination of several trace elements - especially metals - in a variety of environmental samples, including aerosols, water, soils, biological materials and geological materials. Variations of the basic concept include classical IDA, substoichiometric IDA, and more recently, sub-superequivalence IDA. Each variation has its advantages and limitations. A periodic chart has been used to identify those elements which have been measured in environmental samples using one or more of these methods. (author)

  5. Diagnostic herd sensitivity using environmental samples

    DEFF Research Database (Denmark)

    Vigre, Håkan; Josefsen, Mathilde Hartmann; Seyfarth, Anne Mette

    either at farm or slaughter. Three sample matrices were collected; dust samples (5 environmental swabs), nasal swabs (10 pools with 5 animals per pool) and air samples (1 filter). Based on the assumption that MRSA occurred in all 48 herds the overall herd sensitivity was 58% for nasal swabs, 33% for dust....... In our example, the prevalence of infected pigs in each herd was estimated from the pooled samples of nasal swabs. Logistic regression was used to estimate the effect of animal prevalence on the probability to detect MRSA in the dust and air samples at herd level. The results show a significant increase...

  6. Practical reporting times for environmental samples

    International Nuclear Information System (INIS)

    Bayne, C.K.; Schmoyer, D.D.; Jenkins, R.A.

    1993-02-01

    Preanalytical holding times for environmental samples are specified because chemical and physical characteristics may change between sampling and chemical analysis. For example, the Federal Register prescribes a preanalytical holding time of 14 days for volatile organic compounds in soil stored at 4 degrees C. The American Society for Testing Materials (ASTM) uses a more technical definition that the preanalytical holding time is the day when the analyte concentration for an environmental sample falls below the lower 99% confidence interval on the analyte concentration at day zero. This study reviews various holding time definitions and suggest a new preanalytical holding time approach using acceptable error rates for measuring an environmental analyte. This practical reporting time (PRT) approach has been applied to nineteen volatile organic compounds and four explosives in three environmental soil samples. A PRT nomograph of error rates has been developed to estimate the consequences of missing a preanalytical holding time. This nomograph can be applied to a large class of analytes with concentrations that decay linearly or exponentially with time regardless of sample matrices and storage conditions

  7. Practical reporting times for environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Bayne, C.K.; Schmoyer, D.D.; Jenkins, R.A.

    1993-02-01

    Preanalytical holding times for environmental samples are specified because chemical and physical characteristics may change between sampling and chemical analysis. For example, the Federal Register prescribes a preanalytical holding time of 14 days for volatile organic compounds in soil stored at 4{degrees}C. The American Society for Testing Materials (ASTM) uses a more technical definition that the preanalytical holding time is the day when the analyte concentration for an environmental sample falls below the lower 99% confidence interval on the analyte concentration at day zero. This study reviews various holding time definitions and suggest a new preanalytical holding time approach using acceptable error rates for measuring an environmental analyte. This practical reporting time (PRT) approach has been applied to nineteen volatile organic compounds and four explosives in three environmental soil samples. A PRT nomograph of error rates has been developed to estimate the consequences of missing a preanalytical holding time. This nomograph can be applied to a large class of analytes with concentrations that decay linearly or exponentially with time regardless of sample matrices and storage conditions.

  8. Analysis procedure for americium in environmental samples

    International Nuclear Information System (INIS)

    Holloway, R.W.; Hayes, D.W.

    1982-01-01

    Several methods for the analysis of 241 Am in environmental samples were evaluated and a preferred method was selected. This method was modified and used to determine the 241 Am content in sediments, biota, and water. The advantages and limitations of the method are discussed. The method is also suitable for 244 Cm analysis

  9. PIXE - Analysis for environmental and biological samples

    International Nuclear Information System (INIS)

    Baptista, G.B.

    1980-04-01

    The usefulness and accuracy of PIXE as an analytical tool in the study of trace elements in environmental samples of the Brazilian Cerrado are discussed. The report lists actual and forthcoming publications resulting from the study. The mechanism of exchange of elements in solution in water to aerosols has been investigated. For details of the procedure the reader is referred to an earlier report

  10. Surface studies of plasma processed Nb samples

    International Nuclear Information System (INIS)

    Tyagi, Puneet V.; Doleans, Marc; Hannah, Brian S.; Afanador, Ralph; Stewart, Stephen; Mammosser, John; Howell, Matthew P; Saunders, Jeffrey W; Degraff, Brian D; Kim, Sang-Ho

    2015-01-01

    Contaminants present at top surface of superconducting radio frequency (SRF) cavities can act as field emitters and restrict the cavity accelerating gradient. A room temperature in-situ plasma processing technology for SRF cavities aiming to clean hydrocarbons from inner surface of cavities has been recently developed at the Spallation Neutron Source (SNS). Surface studies of the plasma-processed Nb samples by Secondary ion mass spectrometry (SIMS) and Scanning Kelvin Probe (SKP) showed that the NeO_2 plasma processing is very effective to remove carbonaceous contaminants from top surface and improves the surface work function by 0.5 to 1.0 eV.

  11. Determination of Organophosphorous Pesticides in Environmental Water Samples Using Surface-Engineered C18 Functionalized Silica-Coated Core-Shell Magnetic Nanoparticles-Based Extraction Coupled with GC-MS/MS Analysis.

    Science.gov (United States)

    Srivastava, Neha; Kumari, Supriya; Nair, Kishore; Alam, Samsul; Raza, Syed K

    2017-05-01

    The present paper depicts a novel method based on magnetic SPE (MSPE) for the determination of organophosphorus pesticides (OPs) such as phorate, malathion, and chlorpyrifos in environmental water samples. In this study, C18 functionalized silica-coated core-shell iron oxide magnetic nanoparticles (MNPs) were used as a surface-engineered magnetic sorbent for the selective extraction of pesticides from aqueous samples, followed by GC-MS and GC-tandem MS analysis for confirmative determination of the analytes. Various important method parameters, including quantity of MNP adsorbent, volume of sample, effective time for extraction, nature of the desorbing solvent, and pH of the aqueous sample, were investigated and optimized to obtain maximum method performance. Under the optimized instrumental analysis conditions, good linearity (r2 value ≥0.994) was achieved at the concentration range of 0.5-500 μg/L. Recoveries were in the range of 79.2-96.3 and 80.4-97.5% in selective-ion monitoring and multiple reaction monitoring (MRM) modes, respectively, at the spiking concentrations of 1, 5, and 10 μg/L. MRM mode showed better sensitivity, selectivity, and low-level detection (0.5 μg/L) of analytes. The novel MSPE method is a simple, cheap, rapid, and eco-friendly method for the determination of OPs in environmental water samples.

  12. Nuclear techniques for analysis of environmental samples

    International Nuclear Information System (INIS)

    1986-12-01

    The main purposes of this meeting were to establish the state-of-the-art in the field, to identify new research and development that is required to provide an adequate framework for analysis of environmental samples and to assess needs and possibilities for international cooperation in problem areas. This technical report was prepared on the subject based on the contributions made by the participants. A separate abstract was prepared for each of the 9 papers

  13. Environmental sample banking-research and methodology

    International Nuclear Information System (INIS)

    Becker, D.A.

    1976-01-01

    The National Bureau of Standards (NBS), in cooperation with the Environment Protection Agency and the National Science Foundation, is engaged in a research program establishing methodology for environmental sample banking. This program is aimed toward evaluating the feasibility of a National Environment Specimen Bank (NESB). The capability for retrospective chemical analyses to evaluate changes in our environment would provide useful information. Much of this information could not be obtained using data from previously analyzed samples. However, to assure validity for these stored samples, they must be sampled, processed and stored under rigorously evaluated, controlled and documented conditions. The program currently under way in the NBS Analytical Chemistry Division has 3 main components. The first is an extension survey of available literature concerning problems of contamination, losses and storage. The components of interest include trace elements, pesticides, other trace organics (PCBs, plasticizers, etc.), radionuclides and microbiological species. The second component is an experimental evaluation of contamination and losses during sampling and sample handling. Of particular interest here is research into container cleaning methodology for trace elements, with respect to adsorption, desorption, leaching and partial dissolution by various sample matrices. The third component of this program is an evaluation of existing methodology for long-term sample storage

  14. TECHNIQUES WITH POTENTIAL FOR HANDLING ENVIRONMENTAL SAMPLES IN CAPILLARY ELECTROPHORESIS

    Science.gov (United States)

    An assessment of the methods for handling environmental samples prior to capillary electrophoresis (CE) is presented for both aqueous and solid matrices. Sample handling in environmental analyses is the subject of ongoing research at the Environmental Protection Agency's National...

  15. Intrepretation of work area and environmental sampling

    International Nuclear Information System (INIS)

    Ritter, P.D.; Alvarez, J.L.; Novick, V.J.

    1985-01-01

    Meaningful interpretation of widely variable airborne contamination measurements is a difficult problem. Exposure limits, action levels, etc., are rigid interpretations of inherently variable environmental or workplace conditions, and are useful for control and regulatory compliance evaluations. Such limits force actions to reduce contamination, but have limited usefulness as benchmarks for evaluating isolated or nonrepresentative measurements. This paper deals with interpretation of exposure based on nonrepresentative sampling. The use of hard limits for interpreting measurements of legal record simplifies judgment during cursory audits; more aggressive questioning of the validity of these records may effectively invalidate them in a courtroom situation

  16. Determination of strontium-90 in the environmental samples at PINSTECH

    International Nuclear Information System (INIS)

    Perveen, N.; Aziz, A.

    1979-01-01

    Strontium-90 a bone seeking radionuclide and a long lived beta emitter is one of the toxic radionuclides detected in the environment arising mainly from the fall out from nuclear detonations. Its concentration in various environmental media such as air, precipitation, surface water, vegetables and other items of diet was measured. This report describes the method of collection, treatment and radiochemical analyses of environmental samples for the determination of Sr-90. The levels of Sr-90 concentration in these media are also recorded. (authors)

  17. Rapid surface sampling and archival record system

    Energy Technology Data Exchange (ETDEWEB)

    Barren, E.; Penney, C.M.; Sheldon, R.B. [GE Corporate Research and Development Center, Schenectady, NY (United States)] [and others

    1995-10-01

    A number of contamination sites exist in this country where the area and volume of material to be remediated is very large, approaching or exceeding 10{sup 6} m{sup 2} and 10{sup 6} m{sup 3}. Typically, only a small fraction of this material is actually contaminated. In such cases there is a strong economic motivation to test the material with a sufficient density of measurements to identify which portions are uncontaminated, so extensively they be left in place or be disposed of as uncontaminated waste. Unfortunately, since contamination often varies rapidly from position to position, this procedure can involve upwards of one million measurements per site. The situation is complicated further in many cases by the difficulties of sampling porous surfaces, such as concrete. This report describes a method for sampling concretes in which an immediate distinction can be made between contaminated and uncontaminated surfaces. Sample acquisition and analysis will be automated.

  18. Osmium in environmental samples from Northeast Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Rodushkin, Ilia [Division of Applied Geology, Lulea University of Technology, S-971 87 Lulea (Sweden); ALS Laboratory Group, ALS Analytica AB, Aurorum 10, S-977 75 Lulea (Sweden)], E-mail: ilia.rodushkin@alsglobal.com; Engstroem, Emma [Division of Applied Geology, Lulea University of Technology, S-971 87 Lulea (Sweden); Soerlin, Dieke; Ponter, Christer; Baxter, Douglas C. [ALS Laboratory Group, ALS Analytica AB, Aurorum 10, S-977 75 Lulea (Sweden)

    2007-11-01

    Osmium (Os) concentrations and {sup 187}Os/{sup 188}Os isotope abundance ratios are presented for sedimentary materials, soils, humus, plants, mushrooms, mosses and lichens collected in the vicinity of the town of Lulea, Northeast Sweden, the data for biological specimens being the first reported. Contributions from sampling and varying exposure time to the observed environmental variability were evaluated. Sedimentary materials (from both fresh and brackish water) are most elevated in radiogenic {sup 187}Os, followed by inorganic soil horizons, mushrooms and humus. The Os isotopic compositions of plants, mosses and lichens are much less radiogenic, with mean {sup 187}Os/{sup 188}Os lying within a relatively narrow 0.3-0.6 range. Significant temporal variations in Os concentrations and isotopic compositions of plant samples are attributed to integrative uptake of airborne Os with non-radiogenic composition. Measured Os concentrations in biological matrices increase in the order: small shrub leaves (blueberry and lingonberry) {<=} spruce needles {<=} mushrooms {<=} tree leaves {<=} pine needles < mosses << lichens. The concentrations found in three different species of plant were used to provide the first estimates of gaseous osmium tetroxide (OsO{sub 4}) in the environment. Though the Os content of samples from Northeast Sweden does not differ significantly from matrix-matched international reference materials (not certified for Os) of abiotic origin, the estimates of gaseous OsO{sub 4} concentrations are roughly an order of magnitude higher than have been reported for particle-bound Os in other studies. The pronounced spatial variations between relatively closely situated sites in mean {sup 187}Os/{sup 188}Os ratios for samples of the same species (presumably with the same dominating uptake mechanism) point to the presence of different local Os sources. This study therefore demonstrates that emissions of Os from automobile catalytic converters are not the only

  19. Osmium in environmental samples from Northeast Sweden

    International Nuclear Information System (INIS)

    Rodushkin, Ilia; Engstroem, Emma; Soerlin, Dieke; Ponter, Christer; Baxter, Douglas C.

    2007-01-01

    Osmium (Os) concentrations and 187 Os/ 188 Os isotope abundance ratios are presented for sedimentary materials, soils, humus, plants, mushrooms, mosses and lichens collected in the vicinity of the town of Lulea, Northeast Sweden, the data for biological specimens being the first reported. Contributions from sampling and varying exposure time to the observed environmental variability were evaluated. Sedimentary materials (from both fresh and brackish water) are most elevated in radiogenic 187 Os, followed by inorganic soil horizons, mushrooms and humus. The Os isotopic compositions of plants, mosses and lichens are much less radiogenic, with mean 187 Os/ 188 Os lying within a relatively narrow 0.3-0.6 range. Significant temporal variations in Os concentrations and isotopic compositions of plant samples are attributed to integrative uptake of airborne Os with non-radiogenic composition. Measured Os concentrations in biological matrices increase in the order: small shrub leaves (blueberry and lingonberry) ≤ spruce needles ≤ mushrooms ≤ tree leaves ≤ pine needles 4 ) in the environment. Though the Os content of samples from Northeast Sweden does not differ significantly from matrix-matched international reference materials (not certified for Os) of abiotic origin, the estimates of gaseous OsO 4 concentrations are roughly an order of magnitude higher than have been reported for particle-bound Os in other studies. The pronounced spatial variations between relatively closely situated sites in mean 187 Os/ 188 Os ratios for samples of the same species (presumably with the same dominating uptake mechanism) point to the presence of different local Os sources. This study therefore demonstrates that emissions of Os from automobile catalytic converters are not the only source of contemporary environmental contamination

  20. Sorption models and their application in environmental samples

    International Nuclear Information System (INIS)

    Kamel, Nariman H.M.

    2008-01-01

    Full text: Naturally occurring radioactive materials (NORM) were found in some environmental soils not high enough to pose problems for human health. The health may be affected by increasing of NORM at some environmental soils. Four soil samples obtained from certain coastal regions in Egypt. Naturally occurring radioactive materials (NORM) of the uranium ( 238 U) series, thorium ( 232 Th) series and the radioactive isotope of potassium ( 40 K) were measured. The soil samples were selected from the situations where the radionuclide concentrations are significantly higher than the average level of other sites. It were chemically analyzed for the uranium, silicon aluminum and iron. The cation exchange capacity (CEC) were determined, it was found lower in the presence of Fe-silicates suggested that Fe-hydroxide had precipitin at the exchangeable edge sites of the clay minerals. The pH of the solid particles at which the net total surface charge is zero was known as the point of zero charge (PZC). The PZC is very important in determining the affinity of the soil samples for different cations and anions. The aim of this work is to determine the natural radiological hazardous of radionuclide at four environmental coastal soil samples in Egypt. The point of zero surface charge was determined using titration tests. Sorption model was developed for this purpose. (author)

  1. Surface sampling concentration and reaction probe

    Science.gov (United States)

    Van Berkel, Gary J; Elnaggar, Mariam S

    2013-07-16

    A method of analyzing a chemical composition of a specimen is described. The method can include providing a probe comprising an outer capillary tube and an inner capillary tube disposed co-axially within the outer capillary tube, where the inner and outer capillary tubes define a solvent capillary and a sampling capillary in fluid communication with one another at a distal end of the probe; contacting a target site on a surface of a specimen with a solvent in fluid communication with the probe; maintaining a plug volume proximate a solvent-specimen interface, wherein the plug volume is in fluid communication with the probe; draining plug sampling fluid from the plug volume through the sampling capillary; and analyzing a chemical composition of the plug sampling fluid with an analytical instrument. A system for performing the method is also described.

  2. Measurements of plutonium in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    D' Alberti, F; Risposi, L [Instituto di Fisica Applicata, University of Milan, Milan (Italy)

    1996-01-01

    Within the activities connected with the start up of the PETRA Laboratory (Processo per l'Estrazione di Terre Rare ed Attinidi, i.e. process for extraction of rare earths and actinides), the Radiation Protection Unit of the J.R.C.-Ispra has carried out a well planned set of experimental measurements aimed at evaluating the zero point of the isotopes of plutonium in environmental samples by alfa spectrometry. After the International Moratorium in 1963, no release of plutonium has occurred in the environment apart from the burn up of SNAP 9A satellite in April 1964. Since then the plutonium concentration in air and in fallout samples has been continuously decreasing requiring, therefore, optimization of both instrumentation and experimental measurement procedures in order to obtain better sensibilities. In this work, the experimental methodology followed at the J.R.C.-Ispra for measurements of plutonium concentration in air, deposition and soil is described and the plutonium behaviour in these samples is reported and discussed starting from 1961.

  3. Measurements of plutonium in environmental samples

    International Nuclear Information System (INIS)

    D'Alberti, F.; Risposi, L.

    1996-01-01

    Within the activities connected with the start up of the PETRA Laboratory (Processo per l'Estrazione di Terre Rare ed Attinidi, i.e. process for extraction of rare earths and actinides), the Radiation Protection Unit of the J.R.C.-Ispra has carried out a well planned set of experimental measurements aimed at evaluating the zero point of the isotopes of plutonium in environmental samples by alfa spectrometry. After the International Moratorium in 1963, no release of plutonium has occurred in the environment apart from the burn up of SNAP 9A satellite in April 1964. Since then the plutonium concentration in air and in fallout samples has been continuously decreasing requiring, therefore, optimization of both instrumentation and experimental measurement procedures in order to obtain better sensibilities. In this work, the experimental methodology followed at the J.R.C.-Ispra for measurements of plutonium concentration in air, deposition and soil is described and the plutonium behaviour in these samples is reported and discussed starting from 1961

  4. Environmental monitoring master sampling schedule: January--December 1989

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1989-01-01

    Environmental monitoring of the Hanford Site is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for calendar year 1989 for the Surface and Ground-Water Environmental Monitoring Projects. This schedule is subject to modification during the year in response to changes in Site operations, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. This schedule includes routine ground-water sampling performed by PNL for Westinghouse Hanford Company, but does not include samples that may be collected in 1989 to support special studies or special contractor projects, or for quality control. The sampling schedule for Site-wide chemical monitoring is not included here, because it varies each quarter as needed, based on past results and operating needs. This schedule does not include Resource Conservation and Recovery Act ground-water sampling performed by PNL for Hanford Site contractors, nor does it include sampling that may be done by other DOE Hanford contractors

  5. Environmental Sampling, Monitoring and Site Assessment Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — Quality Data Asset includes all current and historical data on environmental quality with regard to the presence of radiological contamination of all kinds regulated...

  6. Program of environmental and bio monitoring sampling

    International Nuclear Information System (INIS)

    Fernandez, H.

    2012-01-01

    This presentation is about the importance of the biological signs to determine the environmental features characteristics.The low level of taxonomic resolution and the environmental perturbation is determined by the bio monitoring techniques

  7. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2006

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2006-01-27

    This document contains the calendar year 2006 schedules for the routine and non-routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes sampling locations, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2006 in which case the anticipated year for collection is provided. The project document package (PDP) for Surface Environmental Surveillance contains the milestone control log for the issuing of CY06 Environmental Surveillance Master Sampling Schedule WBS 4.2.3.21.3.03, milestone: RL00430306 (4830106-12).

  8. Modified electrode voltammetric sensors for trace metals in environmental samples

    Directory of Open Access Journals (Sweden)

    Brett Christopher M.A.

    2000-01-01

    Full Text Available Nafion-modified mercury thin film electrodes have been investigated for the analysis of trace metals in environmental samples of waters and effluent by batch injection analysis with square wave anodic stripping voltammetry. The method, involving injection over the detector electrode of untreated samples of volume of the order of 50 microlitres has fast response, blocking and fouling of the electrode is minimum as shown by studies with surface-active components. Comparison is made between glassy carbon substrate electrodes and carbon fibre microelectrode array substrates, the latter leading to a small sensitivity enhancement. Application to analysis of river water and industrial effluent for labile zinc, cadmium, lead and copper ions is demonstrated in collected samples and after acid digestion.

  9. Application of SIMS to the analysis of environmental samples

    International Nuclear Information System (INIS)

    Seyama, Haruhiko

    2003-01-01

    As an example of surface analysis of environmental samples, SIMS was applied to airborne particulates, fish otoliths (a calcareous ear-stone) and biotites (a rock-forming aluminosilicate mineral). Airborne particulates deposited on leaf surface were analyzed directly by fast atom bombardment (FAB)-SIMS using an O 2 primary neutral beam. Some metal elements, such as Pb, of aerosol origin could be detected. Local areas of a thin section of an otolith were analyzed by FAB-SIMS. Line scans and images of secondary ions revealed seasonal periodicity in Sr, Na and K concentrations in the otolith that corresponded to the annual band structure. Surface alteration of acid-treated and naturally weathered biotites was studied by SIMS depth profiling using an O - primary ion. The depth profile of the acid-treated biotite showed the formation of an altered surface layer rich in Si. In contrast a thick altered surface layer was not observed and Al was held on the surface under natural weathering

  10. EML Surface Air Sampling Program, 1990--1993 data

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, R.J.; Sanderson, C.G.; Kada, J.

    1995-11-01

    Measurements of the concentrations of specific atmospheric radionuclides in air filter samples collected for the Environmental Measurements Laboratory`s Surface Air Sampling Program (SASP) during 1990--1993, with the exception of April 1993, indicate that anthropogenic radionuclides, in both hemispheres, were at or below the lower limits of detection for the sampling and analytical techniques that were used to collect and measure them. The occasional detection of {sup 137}Cs in some air filter samples may have resulted from resuspension of previously deposited debris. Following the April 6, 1993 accident and release of radionuclides into the atmosphere at a reprocessing plant in the Tomsk-7 military nuclear complex located 16 km north of the Siberian city of Tomsk, Russia, weekly air filter samples from Barrow, Alaska; Thule, Greenland and Moosonee, Canada were selected for special analyses. The naturally occurring radioisotopes that the authors measure, {sup 7}Be and {sup 210}Pb, continue to be detected in most air filter samples. Variations in the annual mean concentrations of {sup 7}Be at many of the sites appear to result primarily from changes in the atmospheric production rate of this cosmogenic radionuclide. Short-term variations in the concentrations of {sup 7}Be and {sup 210}Pb continued to be observed at many sites at which weekly air filter samples were analyzed. The monthly gross gamma-ray activity and the monthly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb measured at sampling sites in SASP during 1990--1993 are presented. The weekly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb for samples collected during 1990--1993 are given for 17 sites.

  11. EML Surface Air Sampling Program, 1990--1993 data

    International Nuclear Information System (INIS)

    Larsen, R.J.; Sanderson, C.G.; Kada, J.

    1995-11-01

    Measurements of the concentrations of specific atmospheric radionuclides in air filter samples collected for the Environmental Measurements Laboratory's Surface Air Sampling Program (SASP) during 1990--1993, with the exception of April 1993, indicate that anthropogenic radionuclides, in both hemispheres, were at or below the lower limits of detection for the sampling and analytical techniques that were used to collect and measure them. The occasional detection of 137 Cs in some air filter samples may have resulted from resuspension of previously deposited debris. Following the April 6, 1993 accident and release of radionuclides into the atmosphere at a reprocessing plant in the Tomsk-7 military nuclear complex located 16 km north of the Siberian city of Tomsk, Russia, weekly air filter samples from Barrow, Alaska; Thule, Greenland and Moosonee, Canada were selected for special analyses. The naturally occurring radioisotopes that the authors measure, 7 Be and 210 Pb, continue to be detected in most air filter samples. Variations in the annual mean concentrations of 7 Be at many of the sites appear to result primarily from changes in the atmospheric production rate of this cosmogenic radionuclide. Short-term variations in the concentrations of 7 Be and 210 Pb continued to be observed at many sites at which weekly air filter samples were analyzed. The monthly gross gamma-ray activity and the monthly mean surface air concentrations of 7 Be, 95 Zr, 137 Cs, 144 Ce, and 210 Pb measured at sampling sites in SASP during 1990--1993 are presented. The weekly mean surface air concentrations of 7 Be, 95 Zr, 137 Cs, 144 Ce, and 210 Pb for samples collected during 1990--1993 are given for 17 sites

  12. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2011

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2011-01-21

    This document contains the calendar year 2011 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and the Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2011, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2011.

  13. Surface Environmental Surveillance Procedures Manual, PNL-MA-580, Rev. 5

    Energy Technology Data Exchange (ETDEWEB)

    Hanf, Robert W.; Poston, Ted M.; Bisping, Lynn E.

    2007-07-01

    This manual contains the procedures that are used for the collection of routine Surface Environmental Surveillance Project environmental samples and field measurements on and around the Hanford Site. Specific responsibilities for project personnel are also defined.

  14. Environmental bias and elastic curves on surfaces

    International Nuclear Information System (INIS)

    Guven, Jemal; María Valencia, Dulce; Vázquez-Montejo, Pablo

    2014-01-01

    The behavior of an elastic curve bound to a surface will reflect the geometry of its environment. This may occur in an obvious way: the curve may deform freely along directions tangent to the surface, but not along the surface normal. However, even if the energy itself is symmetric in the curve's geodesic and normal curvatures, which control these modes, very distinct roles are played by the two. If the elastic curve binds preferentially on one side, or is itself assembled on the surface, not only would one expect the bending moduli associated with the two modes to differ, binding along specific directions, reflected in spontaneous values of these curvatures, may be favored. The shape equations describing the equilibrium states of a surface curve described by an elastic energy accommodating environmental factors will be identified by adapting the method of Lagrange multipliers to the Darboux frame associated with the curve. The forces transmitted to the surface along the surface normal will be determined. Features associated with a number of different energies, both of physical relevance and of mathematical interest, are described. The conservation laws associated with trajectories on surface geometries exhibiting continuous symmetries are also examined. (paper)

  15. Quality-control design for surface-water sampling in the National Water-Quality Network

    Science.gov (United States)

    Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.

    2018-04-10

    The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.

  16. Fecal coliforms on environmental surfaces in two day care centers.

    Science.gov (United States)

    Weniger, B G; Ruttenber, A J; Goodman, R A; Juranek, D D; Wahlquist, S P; Smith, J D

    1983-01-01

    A survey of environmental surfaces in two Atlanta area day care centers was conducted to determine the prevalence of fecal coliform bacteria, considered a marker for the presence of fecal contamination which might contain pathogenic parasites, bacteria, or viruses. Fecal coliforms were found in 17 (4.3%) of 398 representative samples of building surfaces, furniture, and other objects. These surfaces may be involved in the chain of transmission of enteric diseases among children. Therefore, disinfection of inanimate objects, in addition to good handwashing, may be important in controlling the spread of enteric diseases in day care centers. PMID:6830225

  17. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2007

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2007-01-31

    This document contains the calendar year 2007 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2007 in which case the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2007.

  18. Radiation Target Area Sample Environmental Chamber (RTASEC), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Payload Systems Inc. proposes the Radiation Target Area Sample Environmental Chamber (RTASEC) as an innovative approach enabling radiobiologists to investigate the...

  19. Applications of Liquid-Phase Microextraction in the Sample Preparation of Environmental Solid Samples

    OpenAIRE

    Helena Prosen

    2014-01-01

    Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc.) published in the last decade. Several...

  20. Total reflection X-ray fluorescence with synchrotron radiation applied to biological and environmental samples

    International Nuclear Information System (INIS)

    Simabuco, S.M.; Matsumoto, E.; Jesus, E.F.O.; Lopes, R.T.; Perez, C.; Nascimento Filho, V.F.; Costa, R.S.S.; Tavares do Carmo, M.G.; Saunders, C.

    2001-01-01

    Full text: The Total Reflection X-ray Fluorescence has been applied for trace elements in water and aqueous solutions, environmental samples and biological materials after sample preparation and to surface analysis of silicon wafers. The present paper shows some results of applications for rainwater, atmospheric particulate material, colostrum and nuclear samples. (author)

  1. Determination of radium-226 in environmental samples

    International Nuclear Information System (INIS)

    Powers, R.P.; Turnage, N.E.; Kanipe, L.G.

    1980-01-01

    The analysis of soil and water samples for 226 Ra by gamma spectrometry with a Ge(Li) detector was compared with that by radiochemical separation followed by 222 Rn de-emanation. Lower limits of detection (LLD) for 226 Ra were calculated for the two analytical techniques. The Ge(Li) system was found to have an LLD for soil comparable to that calculated for the de-emanation procedure, but the Ge(Li) system was found to have a significantly higher LLD for water samples. Cost analysis indicated that the cost of 222 Ra determination with a Ge(Li) system can be less than with the de-emanation procedure if the Ge(Li) system can perform at least one other isotopic anaysis per sample

  2. Sampling quality assurance guidance in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-05-01

    This document introduces quality assurance guidance pertaining to the design and implementation of sampling procedures and processes for collecting environmental data for DOE's Office of EM (Environmental Restoration and Waste Management)

  3. The determination of plutonium isotopes in environmental samples

    International Nuclear Information System (INIS)

    Siripirom, Lopchai.

    1983-01-01

    The concentration of plutonium in environmental samples such as soil, water, and surface air in the middle part of Thailand were studied. The surface air were collected only at the fifth floor of the Office of Atomic Energy for Peace (OAEP). Plutonium-242 was used as a tracer. Soil and air samples were dissolved by pyrosulphate fusion, and plutonium was co-precipitated with barium sulfate. Then dissolved the precipitate in perchloric acid. Plutonium was extracted out by using solvent bis-(2-ethylhexyl) phosphoric acid (HDEHP). Plutonium in water samples were coprecipitated with iron (III) hydroxide and were dissolved in 8 M. nitric acid. Then the plutonium was separated out by using anion exchange resin, Dowex 1x4. After the solvent extraction or the anion exchange, plutonium was coprecipitated with cerous hydroxide. The activities of plutonium were measured by a surface barrier detector for about 24 hours. Lower limit of detection for 1,440 minutes is 0.012 pCi. These studies showed that only plutonium-239, 240 was observed. The range of activities of plutonium-239, 240 in soil were 0.002-0.157 pCi/g (dry), in water were 0.1-81 f Ci/l, and in air were 7-330 a Ci/m 3 . However, the plutonium concentrations in these studies are far below the maximum permissible concentration (MPC) recommended by International Commission on Radiological Protection (ICRP) for general population which is equal to 3x10 8 f Ci/l of water and 5x10 6 a Ci/m 3 of air

  4. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1993-03-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others

  5. DOE methods for evaluating environmental and waste management samples.

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S C; McCulloch, M; Thomas, B L; Riley, R G; Sklarew, D S; Mong, G M; Fadeff, S K [eds.; Pacific Northwest Lab., Richland, WA (United States)

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others.

  6. Analysis of selected phytotoxins and mycotoxins in environmental samples.

    Science.gov (United States)

    Hoerger, Corinne C; Schenzel, Judith; Strobel, Bjarne W; Bucheli, Thomas D

    2009-11-01

    Natural toxins such as phytotoxins and mycotoxins have been studied in food and feed for decades, but little attention has yet been paid to their occurrence in the environment. Because of increasing awareness of the presence and potential relevance of micropollutants in the environment, phytotoxins and mycotoxins should be considered and investigated as part of the chemical cocktail in natural samples. Here, we compile chemical analytical methods to determine important phytotoxins (i.e. phenolic acids, quinones, benzoxazinones, terpenoids, glycoalkaloids, glucosinolates, isothiocyanates, phytosterols, flavonoids, coumestans, lignans, and chalcones) and mycotoxins (i.e. resorcyclic acid lactones, trichothecenes, fumonisins, and aflatoxins) in environmentally relevant matrices such as surface water, waste water-treatment plant influent and effluent, soil, sediment, manure, and sewage sludge. The main problems encountered in many of the reviewed methods were the frequent unavailability of suitable internal standards (especially isotope-labelled analogues) and often absent or fragmentary method optimization and validation.

  7. New trends in sample preparation techniques for environmental analysis.

    Science.gov (United States)

    Ribeiro, Cláudia; Ribeiro, Ana Rita; Maia, Alexandra S; Gonçalves, Virgínia M F; Tiritan, Maria Elizabeth

    2014-01-01

    Environmental samples include a wide variety of complex matrices, with low concentrations of analytes and presence of several interferences. Sample preparation is a critical step and the main source of uncertainties in the analysis of environmental samples, and it is usually laborious, high cost, time consuming, and polluting. In this context, there is increasing interest in developing faster, cost-effective, and environmentally friendly sample preparation techniques. Recently, new methods have been developed and optimized in order to miniaturize extraction steps, to reduce solvent consumption or become solventless, and to automate systems. This review attempts to present an overview of the fundamentals, procedure, and application of the most recently developed sample preparation techniques for the extraction, cleanup, and concentration of organic pollutants from environmental samples. These techniques include: solid phase microextraction, on-line solid phase extraction, microextraction by packed sorbent, dispersive liquid-liquid microextraction, and QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe).

  8. Analysis of mercury in environmental samples

    International Nuclear Information System (INIS)

    Schoester, F.S.

    1992-01-01

    The possibility to determine mercury in sub-ppm levels in biological samples has been studied through neutron activation analysis , using as standards aliquots of mercury nitrate solution, deposited on treated cellulose with thio acetamide and ammonia. Sample and standards were irradiated simultaneously in quartz ampoules during 8 hours at a flux of 5 x 10 13 n/cm 2 s and were counted in a hyper pure germanium detector after 4 weeks of decay. Corrections were made for the interference of 75 Se in the 279 keV photopeak used in the determination. The results obtained for the reference materials IAEA-H-8(horse kidney), IAEA-M A-A2(fish flesh) and IAEA-M A-A-1(cope pod homogenate) were (0.91±0.07), (0.56±0.02) and (0.17±0.02) ppm, versus certified values of (0.91±0.08), (0.47±0.02) and (0.28±0.01) ppm respectively. (EMR). 54 refs., 8 app

  9. Organically bound tritium analysis in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Baglan, N. [CEA/DAM/DIF, Arpajon (France); Kim, S.B. [AECL, Chalk River Laboratories, Chalk River, ON (Canada); Cossonnet, C. [IRSN/PRP-ENV/STEME/LMRE, Orsay (France); Croudace, I.W.; Warwick, P.E. [GAU-Radioanalytical, University of Southampton, Southampton (United Kingdom); Fournier, M. [IRSN/DG/DMQ, Fontenay-aux-Roses (France); Galeriu, D. [IFIN-HH, Horia-Hulubei, Inst. Phys. and Nucl. Eng., Bucharest (Romania); Momoshima, N. [Kyushu University, Radioisotope Ctr., Fukuoka (Japan); Ansoborlo, E. [CEA/DEN/DRCP/CETAMA, Bagnols-sur-Ceze (France)

    2015-03-15

    Organically bound tritium (OBT) has become of increased interest within the last decade, with a focus on its behaviour and also its analysis, which are important to assess tritium distribution in the environment. In contrast, there are no certified reference materials and no standard analytical method through the international organization related to OBT. In order to resolve this issue, an OBT international working group was created in May 2012. Over 20 labs from around the world participated and submitted their results for the first intercomparison exercise results on potato (Sep 2013). The samples, specially-prepared potatoes, were provided in March 2013 to each participant. Technical information and results from this first exercise are discussed here for all the labs which have realised the five replicates necessary to allow a reliable statistical treatment. The results are encouraging as the increased number of participating labs did not degrade the observed dispersion of the results for a similar activity level. Therefore, the results do not seem to depend on the analytical procedure used. From this work an optimised procedure can start to be developed to deal with OBT analysis and will guide subsequent planned OBT trials by the international group.

  10. Near-Surface Engineered Environmental Barrier Integrity

    International Nuclear Information System (INIS)

    Piet, S.J.; Breckenridge, R.P.

    2002-01-01

    The INEEL Environmental Systems Research and Analysis (ESRA) program has launched a new R and D project on Near-Surface Engineered Environmental Barrier Integrity to increase knowledge and capabilities for using engineering and ecological components to improve the integrity of near-surface barriers used to confine contaminants from the public and the environment. The knowledge gained and the capabilities built will help verify the adequacy of past remedial decisions and enable improved solutions for future cleanup decisions. The research is planned to (a) improve the knowledge of degradation mechanisms (weathering, biological, geological, chemical, radiological, and catastrophic) in times shorter than service life, (b) improve modeling of barrier degradation dynamics, (c) develop sensor systems to identify degradation prior to failure, and (d) provide a better basis for developing and testing of new barrier systems to increase reliability and reduce the risk of failure. Our project combine s selected exploratory studies (benchtop and field scale), coupled effects accelerated aging testing and the meso-scale, testing of new monitoring concepts, and modeling of dynamic systems. The performance of evapo-transpiration, capillary, and grout-based barriers will be examined

  11. Ash contents of foodstuff samples in environmental radioactivity analysis

    International Nuclear Information System (INIS)

    Oikawa, Shinji; Ohta, Hiroshi; Hayano, Kazuhiko; Nonaka, Nobuhiro

    2004-01-01

    Statistical data of the ash content in various environmental samples obtained from an environmental radioactivity survey project commissioned by the Japanese government of Science and Technology Agency (at present Ministry of Education, Culture, Sports, Sciences and Technology) during the past 10 years are expressed for establishing a standard of ash content in environmental samples based on radioactivity analysis. The ash content for some kinds of environmental samples such as dietary food, milk, Japanese radish, spinach, fish, green tea and potato was reviewed in the light of statistical and stochastic viewpoints. For all of the samples reviewed in this paper, the coefficient of variation varied from 4.7% for milk to 36.3% for cabbage. Dietary food and milk samples were reviewed more than 1900 and 1400 samples, respectively. Especially, ash content of dietary food depended mainly on the dietary culture reflected on the period. However it showed an almost invariant distribution within 18.7% of coefficient of variation during the past 10 years. Pretreatment of environmental samples especially ashing processes are important from the viewpoint on environmental radioactivity analysis, which is one of the especial fields in analytical chemistry. Statistical reviewed data obtained in this paper may be useful for sample preparation. (author)

  12. Determination of technetium-99 in environmental and radioactive waste samples

    International Nuclear Information System (INIS)

    Ferencova, M.; Peter Tkac, P.

    2007-01-01

    Technetium is known for its high mobility in a soil-water system in non-reducing aerobic condition and also high bio-availability for plants, because the most stable form of technetium in natural surface environment is pertechnetate which is highly soluble. The chemical form of technetium changes with environmental conditions. Concentration of technetium in the environment is very low, therefore many separation steps are needed for technetium determination. It has been developed a method for the routine determination of technetium-99 from environmental matrices and radioactive wastes using technetium-99m as an internal yield monitor. Technetium-99 is extracted from the soil samples with nitric acid. Many contaminants are co-precipitated with ferric hydroxide and technetium in the supernatant is pre-concentrated and further purified using anion exchange chromatography. Final separation of technetium was achieved by extraction with tetraphenylarsonium chloride in chloroform from sulphuric acid or pure water. The chemical yield is determined through the measurement of technetium-99m by scintillation counting system and the technetium-99 activity is measured using proportional counter after decay of the technetium-99m activity. Typical recoveries for this method are in the order 50-60 % (authors)

  13. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2009-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author).

  14. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2013-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author).

  15. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2012-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author).

  16. How to take environmental samples for stable isotope analyses

    International Nuclear Information System (INIS)

    Rogers, K.M.

    2009-01-01

    It is possible to analyse a diverse range of samples for environmental investigations. The main types are soil/sediments, vegetation, fauna, shellfish, waste and water. Each type of samples requires different storage and collection methods. Outlined here are the preferred methods of collection to ensure maximum sample integrity and reliability. (author)

  17. The importance of sound methodology in environmental DNA sampling

    Science.gov (United States)

    T. M. Wilcox; K. J. Carim; M. K. Young; K. S. McKelvey; T. W. Franklin; M. K. Schwartz

    2018-01-01

    Environmental DNA (eDNA) sampling - which enables inferences of species’ presence from genetic material in the environment - is a powerful tool for sampling rare fishes. Numerous studies have demonstrated that eDNA sampling generally provides greater probabilities of detection than traditional techniques (e.g., Thomsen et al. 2012; McKelvey et al. 2016; Valentini et al...

  18. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2005

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2005-01-19

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs. This document contains the calendar year 2005 schedules for the routine and non-routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project.

  19. Methodology of testing environmental samples from the area surrounding radioactive waste deposits

    International Nuclear Information System (INIS)

    Kropikova, S.; Pastuchova, D.

    1979-01-01

    Methods are described of environmental sample investigation in the area surrounding radioactive waste deposits, namely monitoring ground water, surface water, sediments, water flows and catchments, vegetation and soil. Methods of sample preparation, and methods of radionuclides determination in mixtures are also discussed, as are spot activity measurement methods. (author)

  20. Surface reconstruction through poisson disk sampling.

    Directory of Open Access Journals (Sweden)

    Wenguang Hou

    Full Text Available This paper intends to generate the approximate Voronoi diagram in the geodesic metric for some unbiased samples selected from original points. The mesh model of seeds is then constructed on basis of the Voronoi diagram. Rather than constructing the Voronoi diagram for all original points, the proposed strategy is to run around the obstacle that the geodesic distances among neighboring points are sensitive to nearest neighbor definition. It is obvious that the reconstructed model is the level of detail of original points. Hence, our main motivation is to deal with the redundant scattered points. In implementation, Poisson disk sampling is taken to select seeds and helps to produce the Voronoi diagram. Adaptive reconstructions can be achieved by slightly changing the uniform strategy in selecting seeds. Behaviors of this method are investigated and accuracy evaluations are done. Experimental results show the proposed method is reliable and effective.

  1. chemical and microbiological assessment of surface water samples

    African Journals Online (AJOL)

    PROF EKWUEME

    were investigated in this study: Nine samples from different surface water bodies, two samples from two effluent sources ... Ezeagu, Udi, Nkanu, Oji River and some parts of Awgu and Aninri ..... Study of Stream Output from Small Catchments.

  2. Applications of liquid-phase microextraction in the sample preparation of environmental solid samples.

    Science.gov (United States)

    Prosen, Helena

    2014-05-23

    Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc.) published in the last decade. Several innovative liquid-phase microextraction (LPME) techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME), hollow fiber-liquid phase microextraction (HF-LPME), dispersive liquid-liquid microextraction (DLLME). Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  3. Applications of Liquid-Phase Microextraction in the Sample Preparation of Environmental Solid Samples

    Directory of Open Access Journals (Sweden)

    Helena Prosen

    2014-05-01

    Full Text Available Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc. published in the last decade. Several innovative liquid-phase microextraction (LPME techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME, hollow fiber-liquid phase microextraction (HF-LPME, dispersive liquid-liquid microextraction (DLLME. Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  4. Natural Radioactivity Pattern of Surabaya Water Environmental Samples

    International Nuclear Information System (INIS)

    Rosidi; Agus Taftazani

    2007-01-01

    The gross β radioactivity and natural radionuclide of Surabaya environmental samples pattern have been evaluated. The environmental samples were chosen randomly at 12 locations. The environment samples were water (fresh, estuary and coastal), sediment, eichhornia crassipes (Mart) Solms, Mangrove (Rhizophora stylosa), (Moolgarda delicatus) fish and (Johnius (Johnieops) borneensis) (Sharpnose hammer croaker) fish. The water sample was evaporated; the sediment sample was dried and ground; the biotic samples was burnt at the temperature 500 °C ; The gross β measurement using GM detector and the radionuclides has been identified by γ spectrometer. From the investigation results could be concluded that the natural radioactivity of environmental samples was very low. gross-β of water samples were lower than the threshold value of local government regulation of Surabaya no: 2 year 2004 (1 Bq/L). The distribution of gross-β activity of eichhornia crassipes (Mart) Solms was higher than the other biotic, water and sediment samples as well as the accumulation of radionuclides in the water organism was taken place. The result of identification using γ spectrometer has detected 7 of radionuclides, i.e 210 Pb, 212 Pb, 214 Pb, 208 Tl, 214 Bi, 228 Ac, and 40 K in all sample. The distribution factor of sediment F D was less than bioaccumulation factor of biotic F B and it indicates that there the radionuclide accumulation migration follows the pattern of water - sediment - biotic sample. (author)

  5. Gamma spectrometric analyses of environmental samples at PINSTECH

    International Nuclear Information System (INIS)

    Faruq, M.U.; Parveen, N.; Ahmed, B.; Aziz, A.

    1979-01-01

    Gamma spectrometric analyses of air and other environmental samples from PINSTECH were carried out. Air particulate samples were analyzed by a Ge(Li) detector on a computer-based multichannel analyzer. Other environmental samples were analyzed by a Na(T1) scintillation detector spectrometer and a multichannel analyzer with manual analysis. Concentration of radionuclides in the media was determined and the sources of their production were identified. Age of the fall out was estimated from the ratios of the fission products. (authors)

  6. Sampling procedure for lake or stream surface water chemistry

    Science.gov (United States)

    Robert Musselman

    2012-01-01

    Surface waters collected in the field for chemical analyses are easily contaminated. This research note presents a step-by-step detailed description of how to avoid sample contamination when field collecting, processing, and transporting surface water samples for laboratory analysis.

  7. Radiological analyses of Marshall Islands environmental samples, 1974--1976

    International Nuclear Information System (INIS)

    Greenhouse, N.A.; Miltenberger, R.P.; Cua, F.T.

    1977-01-01

    Results are reported from the radiological analysis of environmental samples collected in the Marshall Islands during 1974 through 1976. Most of the samples were collected on or near the Bikini Atoll and included plants, soil, fish, catchment water, and sediments, with emphasis on local marine and terrestrial food items. Data are presented from γ spectral analysis and the content of 90 Sr and transuranic elements in the samples

  8. Screening of IAEA environmental samples for fissile material content

    International Nuclear Information System (INIS)

    Hembree, Doyle M. Jr.; Carter, Joel A.; Devault, Gerald L.; Whitaker, J. Michael; Glasgow, David

    2001-01-01

    Full text: Analysis of environmental samples for the International Atomic Energy Agency (IAEA) Strengthened Safeguards Systems program requires that stringent measures be taken to control contamination. To facilitate contamination control, it is extremely useful to have some estimate of the fissile content of a given sample prior to beginning sample preparation and analysis. This is particularly true for laboratories that employ clean rooms during sample preparation. A review of the analytical results for samples submitted between January 1, 1999 and September 1, 2000 revealed that the total uranium content values ranged from 0.2 to greater than 500,000 ng/sample. Poor estimates of the uranium or plutonium content in the samples have caused some of the laboratories in the IAEA Network of Analytical Laboratories (NWAL) to experience clean laboratory contamination, sample cross contamination, and non-ideal uranium spike additions. This has led to significant increases in analysis costs (e.g., recertification of clean rooms after removing contamination, and rerunning samples) and degradation in data quality. A number of methods have been proposed for screening environmental samples for fissile material content, including gamma spectrometry, x-ray fluorescence, kinetic phosphorimetry (KPA), and inductively coupled plasma-mass spectrometry (ICP-MS). Gamma spectrometry and x-ray fluorescence are suitable for screening samples with microgram or greater quantities of uranium. ICP-MS and KPA are used successfully in some DOE NWAL laboratories to screen environmental samples. A neutron activation analysis (NAA) method that offers numerous advantages over other screening techniques for environmental samples has recently been proposed. Fissile materials such as 239 Pu and 235 U can be made to undergo fission in the intense neutron field to which they are exposed during neutron activation analysis (NAA). Some of the fission products emit neutrons referred to as 'delayed

  9. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2010

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2010-01-08

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by Pacific Northwest National Laboratory for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford Site environs per regulatory requirements. This document contains the calendar year 2010 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and the Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2010, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2010.

  10. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2009

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2009-01-20

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory for the U.S. Department of Energy. Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 450.1 and DOE Order 5400.5. This document contains the calendar year 2009 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2009, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2009.

  11. Determination of Pu, Am and Cm in Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Lujaniene, G. [SRI Centre for Physical Sciences and Technology, Vilnius (Lithuania)

    2013-07-15

    The determination of actinides in the environmental samples at a lower detection limit is required for monitoring purposes and for environmental research. The method for Pu, Am and Cm measurements in soil and sediment samples provides high recoveries and good decontamination from interfering radionuclides. The main steps of the method involve digestion of the samples, separation of radionuclides from matrix using the TOPO /cyclohexane extraction and final purification using extraction Eichrom resins (TEVA, TRU). The accuracy and precision of Pu, Am and Cm analyses were tested using IAEA RM No 135, NIST SRM No 4350b, No 4357 and in intercomparison runs organized by the Riso National Laboratory, Denmark, and in the proficiency tests organized by National Physical Laboratory, UK. The method was applied for measurement of radionuclides in aerosol samples (ashes {approx}30 g), bottom sediments (50-80 g dr. wt) and soil (including Chernobyl soil) samples. (author)

  12. Development of analytical techniques for safeguards environmental samples at JAEA

    International Nuclear Information System (INIS)

    Sakurai, Satoshi; Magara, Masaaki; Usuda, Shigekazu; Watanabe, Kazuo; Esaka, Fumitaka; Hirayama, Fumio; Lee, Chi-Gyu; Yasuda, Kenichiro; Inagawa, Jun; Suzuki, Daisuke; Iguchi, Kazunari; Kokubu, Yoko S.; Miyamoto, Yutaka; Ohzu, Akira

    2007-01-01

    JAEA has been developing, under the auspices of the Ministry of Education, Culture, Sports, Science and Technology of Japan, analytical techniques for ultra-trace amounts of nuclear materials in environmental samples in order to contribute to the strengthened safeguards system. Development of essential techniques for bulk and particle analysis, as well as screening, of the environmental swipe samples has been established as ultra-trace analytical methods of uranium and plutonium. In January 2003, JAEA was qualified, including its quality control system, as a member of the JAEA network analytical laboratories for environmental samples. Since 2004, JAEA has conducted the analysis of domestic and the IAEA samples, through which JAEA's analytical capability has been verified and improved. In parallel, advanced techniques have been developed in order to expand the applicability to the samples of various elemental composition and impurities and to improve analytical accuracy and efficiency. This paper summarizes the trace of the technical development in environmental sample analysis at JAEA, and refers to recent trends of research and development in this field. (author)

  13. Detection of the actinides and cesium from environmental samples

    Science.gov (United States)

    Snow, Mathew Spencer

    Detection of the actinides and cesium in the environment is important for a variety of applications ranging from environmental remediation to safeguards and nuclear forensics. The utilization of multiple different elemental concentrations and isotopic ratios together can significantly improve the ability to attribute contamination to a unique source term and/or generation process; however, the utilization of multiple elemental "signatures" together from environmental samples requires knowledge of the impact of chemical fractionation for various elements under a variety of environmental conditions (including predominantly aqueous versus arid conditions). The research reported in this dissertation focuses on three major areas: 1. Improving the understanding of actinide-mineral interactions at ultra-low concentrations. Chapter 2 reports a batch sorption and modeling study of Np(V) sorption to the mineral goethite from attomolar to micromolar concentrations. 2. Improving the detection capabilities for Thermal Ionization Mass Spectrometry (TIMS) analyses of ultra-trace cesium from environmental samples. Chapter 4 reports a new method which significantly improves the chemical yields, purification, sample processing time, and ultimately, the detection limits for TIMS analyses of femtogram quantities of cesium from a variety of environmental sample matrices. 3. Demonstrating how actinide and cesium concentrations and isotopic ratios from environmental samples can be utilized together to determine a wealth of information including environmental transport mechanisms (e.g. aqueous versus arid transport) and information on the processes which generated the original material. Chapters1, 3 and 5 demonstrate these principles using Pu, Am, Np, and Cs concentrations and isotopic ratios from contaminated soils taken near the Subsurface Disposal Area (SDA) of Idaho National Laboratory (INL) (a low level radioactive waste disposal site in southeastern Idaho).

  14. Determination of technetium-99 in environmental samples: A review

    DEFF Research Database (Denmark)

    Shi, Keliang; Hou, Xiaolin; Roos, Per

    2012-01-01

    Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99Tc is also an important tracer for oceanographic...... research due to the high technetium solubility in seawater as TcO4−. A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99Tc in different environmental samples....... This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99Tc. Due to the extremely low concentration of 99Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal...

  15. Environmental Radionuclides in Surface Soils of Vietnam

    International Nuclear Information System (INIS)

    Hien, P.D.; Hiep, H.T.; Quang, N.H.; Luyen, T.V.; Binh, T.V.; Ngo, N.T.; Long, N.Q.; Bac, V.T.

    2012-01-01

    A database on 238 U, 232 Th, 40 K and 137 Cs in surface soils was established to provide inputs for the assessment of the collective dose to the population of Vietnam and to support soil erosion studies using 137 Cs as a tracer. A total of 292 soil samples were taken from undisturbed sites across the territory and the concentrations of radionuclides were determined by gamma spectrometry method. The multiple regression of 137 Cs inventories against characteristics of sampling locations allowed us to establish the distribution of 137 Cs deposition density and its relationship with latitude and annual rainfall. The 137 Cs deposition density increases northward and varies from 178 Bq m -2 to 1,920 Bq m -2 . High rainfall areas in the northern and central parts of the country have received considerable 137 Cs inputs exceeding 600 Bq m -2 , which is the maximum value that can be expected for Vietnam from the UNSCEAR global pattern. The mean activity concentrations of naturally occurring radionuclides 238 U, 232 Th and 40 K are 45, 59 and 401 Bq kg- 1 , respectively, which entail an average absorbed dose rate in air of 62 nGy h -1 , which is about 7% higher than the world average. (author)

  16. AAS determination of total mercury content in environmental samples

    International Nuclear Information System (INIS)

    Moskalova, M.; Zemberyova, M.

    1997-01-01

    Two methods for determination of total mercury content in environmental samples soils, and sediments, were compared. Dissolution procedure of soils, sediments, and biological material under elevated pressure followed by determination of mercury by cold vapour atomic absorption spectrometry using a MHS-1 system and direct total mercury determination without any chemical pretreatment from soil samples using a Trace Mercury Analyzer TMA-254 were compared. TMA-254 was also applied for the determination of mercury in various further standard reference materials. Good agreement with certified values of environmental reference materials was obtained. (authors)

  17. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2008

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2008-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by Pacific Northwest National Laboratory for the U.S. Department of Energy. Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 450.1, "Environmental Protection Program," and DOE Order 5400.5, "Radiation Protection of the Public and the Environment." The environmental surveillance sampling design is described in the "Hanford Site Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office." This document contains the calendar year 2008 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2008, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2008.

  18. Sample preparation of environmental samples using benzene synthesis followed by high-performance LSC

    International Nuclear Information System (INIS)

    Filippis, S. De; Noakes, J.E.

    1991-01-01

    Liquid scintillation counting (LSC) techniques have been widely employed as the detection method for determining environmental levels of tritium and 14 C. Since anthropogenic and nonanthropogenic inputs to the environment are a concern, sampling the environment surrounding a nuclear power facility or fuel reprocessing operation requires the collection of many different sample types, including agriculture products, water, biota, aquatic life, soil, and vegetation. These sample types are not suitable for the direct detection of tritium of 14 C for liquid scintillation techniques. Each sample type must be initially prepared in order to obtain the carbon or hydrogen component of interest and present this in a chemical form that is compatible with common chemicals used in scintillation counting applications. Converting the sample of interest to chemically pure benzene as a sample preparation technique has been widely accepted for processing samples for radiocarbon age-dating applications. The synthesized benzene is composed of the carbon or hydrogen atoms from the original sample and is ideal as a solvent for LSC with excellent photo-optical properties. Benzene synthesis followed by low-background scintillation counting can be applied to the preparation and measurement of environmental samples yielding good detection sensitivities, high radionuclide counting efficiency, and shorter preparation time. The method of benzene synthesis provides a unique approach to the preparation of a wide variety of environmental sample types using similar chemistry for all samples

  19. Multiwalled Carbon Nanotube Deposition on Model Environmental Surfaces

    Science.gov (United States)

    Deposition of multiwalled carbon nanotubes (MWNTs) on model environmental surfaces was investigated using a quartz crystal microbalance with dissipation monitoring (QCM-D). Deposition behaviors of MWNTs on positively and negatively charged surfaces were in good agreement with Der...

  20. Determination of technetium-99 in environmental samples: A review

    International Nuclear Information System (INIS)

    Shi Keliang; Hou Xiaolin; Roos, Per; Wu Wangsuo

    2012-01-01

    Highlights: ► The source term, physicochemical properties, environmental distribution and behaviour of 99 Tc are presented. ► Various sample pre-treatment and pre-concentration techniques of technetium are discussed. ► Chemical separation and purification techniques for 99 Tc in environmental samples are reviewed. ► Measurement techniques for 99 Tc in environmental level and automated analytical methods are reviewed. ► The reported analytical methods of 99 Tc are critically compared to provide overall information. - Abstract: Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99 Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99 Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO 4 − . A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99 Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99 Tc. Due to the extremely low concentration of 99 Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of 99 Tc are the most important issues governing the accurate determination of 99 Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for 99 Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of 99 Tc using solid extraction or ion exchange chromatography for separation of 99 Tc, employing flow injection or sequential injection approaches are also discussed.

  1. Determination of uranium and its isotopic ratios in environmental samples

    International Nuclear Information System (INIS)

    Flues Szeles, M.S.M.

    1990-01-01

    A method for the determination of uranium and its isotopic ratios ( sup(235)U/ sup(238)U and sup(234U/ sup(238)U) is established in the present work. The method can be applied in environmental monitoring programs of uranium enrichment facilities. The proposed method is based on the alpha spectrometry technique which is applied after a purification of the sample by using an ionic exchange resin. The total yield achieved was (91 + 5)% with a precision of 5%, an accuracy of 8% and a lower limit of detection of 7,9 x 10 sup(-4)Bq. The uranium determination in samples containing high concentration of iron, which is an interfering element present in environmental samples, particularly in soil and sediment, was also studied. The results obtained by using artificial samples containing iron and uranium in the ratio 1000:1, were considered satisfactory. (author)

  2. Preparation, characterization, and applications of a novel solid-phase microextraction fiber by sol-gel technology on the surface of stainless steel wire for determination of poly cyclic aromatic hydrocarbons in aquatic environmental samples

    International Nuclear Information System (INIS)

    Es-haghi, Ali; Hosseininasab, Valiallah; Bagheri, Habib

    2014-01-01

    Graphical abstract: - Highlights: • A novel solid-phase microextraction (SPME) fiber was prepared using sol–gel technology. • Sol–gel coating was performed on stainless steel substrate. • The new fibers are robust and unbreakable with temperature stability. • The fibers were used for extraction of PAHs from aqueous samples. - Abstract: A novel solid-phase microextraction(SPME) fiber was prepared using sol–gel technology with ethoxylated nonylphenol as a fiber coating material. The fiber was employed to develop a headspace SPME–GC–MS method suitable for quantification of 13 polycyclic aromatic hydrocarbons (PAHs) in water samples. Surface characteristics of the fibers were inspected by energy dispersive X-ray (EDX) spectroscopy as well as by scanning electron microscopy (SEM). The SEM measurements showed the presence of highly porous nano-sized particles in the coating. Important parameters affecting the extraction efficiency such as extraction temperature and time, desorption conditions as well as ionic strength have been evaluated and optimized. In the next step, the validation of the new method have been performed, finding it to be specific in the trace analysis of PAHs, with the limit of detection (LOD) ranging from 0.01 to 0.5 μg L −1 and the linear range from the respective LOD to 200 μg L −1 with RSD amounting to less than 8%. The thermal stability of the fibers was investigated as well and they were found to be durable at 280 °C for 345 min. Furthermore, the proposed method was successfully applied for quantification of PAHs in real water samples

  3. Preparation, characterization, and applications of a novel solid-phase microextraction fiber by sol-gel technology on the surface of stainless steel wire for determination of poly cyclic aromatic hydrocarbons in aquatic environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Es-haghi, Ali, E-mail: a.eshaghi@rvsri.ac.ir [Department of Physico Chemistry, Razi Vaccine and Serum Research Institute, PO Box 31975/148, Karaj (Iran, Islamic Republic of); Hosseininasab, Valiallah; Bagheri, Habib [Environmental and Bio-Analytical Laboratories, Department of Chemistry, Sharif University of Technology, PO Box 11365-9516, Tehran (Iran, Islamic Republic of)

    2014-02-01

    Highlights: • A novel solid-phase microextraction (SPME) fiber was prepared using sol–gel technology. • Sol–gel coating was performed on stainless steel substrate. • The new fibers are robust and unbreakable with temperature stability. • The fibers were used for extraction of PAHs from aqueous samples. Abstract: A novel solid-phase microextraction(SPME) fiber was prepared using sol–gel technology with ethoxylated nonylphenol as a fiber coating material. The fiber was employed to develop a headspace SPME–GC–MS method suitable for quantification of 13 polycyclic aromatic hydrocarbons (PAHs) in water samples. Surface characteristics of the fibers were inspected by energy dispersive X-ray (EDX) spectroscopy as well as by scanning electron microscopy (SEM). The SEM measurements showed the presence of highly porous nano-sized particles in the coating. Important parameters affecting the extraction efficiency such as extraction temperature and time, desorption conditions as well as ionic strength have been evaluated and optimized. In the next step, the validation of the new method have been performed, finding it to be specific in the trace analysis of PAHs, with the limit of detection (LOD) ranging from 0.01 to 0.5 μg L⁻¹ and the linear range from the respective LOD to 200 μg L⁻¹with RSD amounting to less than 8%. The thermal stability of the fibers was investigated as well and they were found to be durable at 280 °C for 345 min. Furthermore, the proposed method was successfully applied for quantification of PAHs in real water samples.

  4. Gamma-ray self-attenuation corrections in environmental samples

    International Nuclear Information System (INIS)

    Robu, E.; Giovani, C.

    2009-01-01

    Gamma-spectrometry is a commonly used technique in environmental radioactivity monitoring. Frequently the bulk samples that should be measured differ with respect to composition and density from the reference sample used for efficiency calibration. Correction factors should be applied in these cases for activity measurement. Linear attenuation coefficients and self-absorption correction factors have been evaluated for soil, grass and liquid sources with different densities and geometries.(authors)

  5. Isolation of Arcobacter butzleri in environmental and food samples collected in industrial and artisanal dairy plants

    Directory of Open Access Journals (Sweden)

    Federica Giacometti

    2013-10-01

    Full Text Available This study investigated the presence of Arcobacter species in two cheese factories; a total of 22 environmental samples and 10 food samples were collected from an artisanal and an industrial cheese factory; Arcobacter species were isolated after enrichment, and isolates were identified at species level by multiplex-polymerase chain reaction (PCR assay. In the artisanal cheese factory, Arcobacter spp. were isolated from several environmental samples, cow and water buffalo raw milk and ricotta cheese. In the industrial plant, Arcobacter spp. were isolated from surfaces not in contact with food and from a cleaned surface in contact with food; no Arcobacter spp. was isolated from food. All isolates were identified as A. butzleri. We report of the presence of A. butzleri in a ready-to-eat cheese produced for retail. In addition, the isolation of A. butzleri in food processing surfaces in the two cheese factories could be assessed as a source of potential contamination for cheeses

  6. Data Set for the manuscript entitled, "Sample Processing Approach for Detection of Ricin in Surface Samples."

    Data.gov (United States)

    U.S. Environmental Protection Agency — Figure. This dataset is associated with the following publication: Shah, S., S. Kane, A.M. Erler, and T. Alfaro. Sample Processing Approach for Detection of Ricin in...

  7. Efficient maximal Poisson-disk sampling and remeshing on surfaces

    KAUST Repository

    Guo, Jianwei; Yan, Dongming; Jia, Xiaohong; Zhang, Xiaopeng

    2015-01-01

    Poisson-disk sampling is one of the fundamental research problems in computer graphics that has many applications. In this paper, we study the problem of maximal Poisson-disk sampling on mesh surfaces. We present a simple approach that generalizes the 2D maximal sampling framework to surfaces. The key observation is to use a subdivided mesh as the sampling domain for conflict checking and void detection. Our approach improves the state-of-the-art approach in efficiency, quality and the memory consumption.

  8. Efficient maximal Poisson-disk sampling and remeshing on surfaces

    KAUST Repository

    Guo, Jianwei

    2015-02-01

    Poisson-disk sampling is one of the fundamental research problems in computer graphics that has many applications. In this paper, we study the problem of maximal Poisson-disk sampling on mesh surfaces. We present a simple approach that generalizes the 2D maximal sampling framework to surfaces. The key observation is to use a subdivided mesh as the sampling domain for conflict checking and void detection. Our approach improves the state-of-the-art approach in efficiency, quality and the memory consumption.

  9. Fluoroquinolone antibiotics in environmental waters: sample preparation and determination.

    Science.gov (United States)

    Speltini, Andrea; Sturini, Michela; Maraschi, Federica; Profumo, Antonella

    2010-04-01

    The aim of this review is to provide a general overview on the analytical methods proposed in the last decade for trace fluoroquinolone (FQ) determination in environmental waters. A large number of studies have been developed on this topic in reason of the importance of their monitoring in the studies of environmental mobility and potential degradation pathways. Every step of the analysis has been carefully considered, with a particular attention to sample preparation, in relationship with the problems involved in the analysis of real matrices. The different strategies to minimise interference from organic matter and to achieve optimal sensitivity, especially important in those samples with lower FQ concentrations, were also highlighted. Results and progress in this field have been described and critically commented. Moreover, a worldwide overview on the presence of FQs in the environmental waters has been reported.

  10. Rapid methods for measuring radionuclides in food and environmental samples

    International Nuclear Information System (INIS)

    Perkins, Richard W.

    1995-01-01

    The application of ICP/mass spectrometry for the isotopic analysis of environmental samples, the use of drum assayers for measuring radionuclides in food and a rapid procedure for the measurement of the transuranic elements and thorium, performed at the Pacific Northwest Laboratory are discussed

  11. Tritium analysis in environmental samples around Nuclear Power Plants and nationwide surveillance of radionuclides in some environmental samples(meat and drinking water)

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Woo; Han, Man Jung; Cho, Seong Won; Cho, Hong Jun; Oh, Hyeon Kyun; Lee, Jeong Min; Chang, Jae Sook [KORTIC, Taejon (Korea, Republic of)

    2001-12-15

    12 kind of environmental samples such as soil, underground water, seawater, etc. around the Nuclear Power Plants(NPP) and surface seawater around the Korea peninsula were sampled, For the samples of rain, pine-needle, air, seawater, underground water, chinese cabbage, grain of rice and milk sampled around NPP, and surface seawater and rain sampled all around country, tritium concentration was measured, The tritium concentration in the tap water and the gamma activity in the domestic and imported beef that were sampled at ward in the large city in Korea(Seoul, Pusan, Taegu, Taejun, Inchun, Kwangju) were analyzed for the meat and drinking waters. As the results of analyzing, tritium concentration in rain and tap water were very low all around country, but a little higher around the NPP than general surrounding. At the Wolsung NPP, tritium concentration was descend according to distance from the stack. Tritium activity of surface seawater around the Korea peninsula was also, very low. The measured radioactive elements in the beef is the same as the radioactive elements on the earth surface.

  12. Interpolating and sampling sequences in finite Riemann surfaces

    OpenAIRE

    Ortega-Cerda, Joaquim

    2007-01-01

    We provide a description of the interpolating and sampling sequences on a space of holomorphic functions on a finite Riemann surface, where a uniform growth restriction is imposed on the holomorphic functions.

  13. Capacity constrained blue-noise sampling on surfaces

    KAUST Repository

    Zhang, Sen; Guo, Jianwei; Zhang, Hui; Jia, Xiaohong; Yan, Dongming; Yong, Junhai; Wonka, Peter

    2015-01-01

    regularizer of the Centroidal Voronoi Tessellation (CVT) energy, our approach enforces an exact capacity constraint using the restricted power tessellation on surfaces. Our approach is a generalization of the previous 2D blue noise sampling technique using

  14. Surface Resistance Measurements of LHC Dipole Beam Screen Samples

    CERN Document Server

    Caspers, Friedhelm; Ruggiero, F; Tan, J; Tsutsui, H

    2000-01-01

    An estimate of the resistive losses in the LHC dipole beam screen is given from cold surface resistance measurements using the shielded pair technique. Several beam screen samples have been evaluated, with different copper coating methods, including a sample with ribbed surface envisaged to reduce electron cloud losses thanks to its low reflectivity. Experimental data, derived by a proper analysis of the measured Q-factors and including error estimates are compared with theoretical predictions of the anomalous skin effect.

  15. Analytical techniques for measurement of 99Tc in environmental samples

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Three new methods have been developed for measuring 99 Tc in environmental samples. The most sensitive method is isotope dilution mass spectrometry, which allows measurement of about 1 x 10 -12 grams of 99 Tc. Results on analysis of five samples by this method compare very well with values obtained by a second independent method, which involves counting of beta particles from 99 Tc and internal conversion electrons from /sup 97m/Tc. A third method involving electrothermal atomic absorption has also been developed. Although this method is not as sensitive as the first two techniques, the cost per analysis is expected to be considerably less for certain types of samples

  16. Infrared characterization of environmental samples by pulsed photothermal spectroscopy

    International Nuclear Information System (INIS)

    Seidel, W.; Foerstendorf, H.; Heise, K.H.; Nicolai, R.; Schamlott, A.; Ortega, J.M.; Glotin, F.; Prazeres, R.

    2004-01-01

    Low concentration of toxic radioactive metals in environmental samples often limits the interpretation of results of infrared studies investigating the interaction processes between the metal ions and environmental compartments. For the first time, we could show that photothermal infrared spectroscopy performed with a pulsed free electron laser can provide reliable infrared spectra throughout a distinct spectral range of interest. In this model investigation, we provide vibrational absorption spectra of a rare earth metal salt dissolved in a KBr matrix and a natural calcite sample obtained by photothermal beam deflection (PTBD) technique and FT-IR (Fourier-transform infrared) spectroscopy, respectively. General agreement was found between all spectra of the different recording techniques. Spectral deviations were observed with samples containing low concentration of the rare earth metal salt indicating a lower detection limit of the photothermal method as compared to conventional FT-IR spectroscopy. (authors)

  17. Environmental monitoring master sampling schedule, January--December 1990

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1990-01-01

    Environmental monitoring of the Hanford Site is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for calendar year 1990 for the Environment Surveillance and Ground-Water Monitoring Projects. This schedule is subject to modification during the year in response to changes in Site operations, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs. This schedule includes ground-water sampling performed by PNL for environmental surveillance of the Hanford Site.

  18. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Laboratory Management Division of the DOE. Methods are prepared for entry into DOE Methods as chapter editors, together with DOE and other participants in this program, identify analytical and sampling method needs. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types. open-quotes Draftclose quotes or open-quotes Verified.close quotes. open-quotes Draftclose quotes methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. open-quotes Verifiedclose quotes methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations

  19. Zoonotic pathogens isolated from wild animals and environmental samples at two California wildlife hospitals.

    Science.gov (United States)

    Siembieda, Jennifer L; Miller, Woutrina A; Byrne, Barbara A; Ziccardi, Michael H; Anderson, Nancy; Chouicha, Nadira; Sandrock, Christian E; Johnson, Christine K

    2011-03-15

    To determine types and estimate prevalence of potentially zoonotic enteric pathogens shed by wild animals admitted to either of 2 wildlife hospitals and to characterize distribution of these pathogens and of aerobic bacteria in a hospital environment. Cross-sectional study. Fecal samples from 338 animals in 2 wildlife hospitals and environmental samples from 1 wildlife hospital. Fecal samples were collected within 24 hours of hospital admission. Environmental samples were collected from air and surfaces. Samples were tested for zoonotic pathogens via culture techniques and biochemical analyses. Prevalence of pathogen shedding was compared among species groups, ages, sexes, and seasons. Bacterial counts were determined for environmental samples. Campylobacter spp, Vibrio spp, Salmonella spp, Giardia spp, and Cryptosporidium spp (alone or in combination) were detected in 105 of 338 (31%) fecal samples. Campylobacter spp were isolated only from birds. Juvenile passerines were more likely to shed Campylobacter spp than were adults; prevalence increased among juvenile passerines during summer. Non-O1 serotypes of Vibrio cholerae were isolated from birds; during an oil-spill response, 9 of 10 seabirds screened were shedding this pathogen, which was also detected in environmental samples. Salmonella spp and Giardia spp were isolated from birds and mammals; Cryptosporidium spp were isolated from mammals only. Floors of animal rooms had higher bacterial counts than did floors with only human traffic. Potentially zoonotic enteric pathogens were identified in samples from several species admitted to wildlife hospitals, indicating potential for transmission if prevention is not practiced.

  20. Experience with environmental sampling at gas centrifuge enrichment plants

    International Nuclear Information System (INIS)

    Ekenstam, G. af; Bush, W.; Janov, J.; Kuhn, E.; Ryjinski, M.

    2001-01-01

    Environmental sampling has been used routinely by the IAEA since 1996 after the IAEA Board of Governors approved it in March 1995 as a new technique to strengthen safeguards and improve efficiency. In enrichment plants it is used to confirm that there has been no production of highly enriched uranium (HEU), or production of uranium at above the declared enrichment. The use of environmental sampling is based on the assumption that every process, no matter how leak tight, will release small amounts of process material to the environment. Even though these releases of nuclear material are extremely small in gas centrifuge enrichment plants, and well below levels of concern from a health physics and safety standpoint, they are detectable and their analysis provides an indication of the enrichment of the material that has been processed in the plant. The environmental samples at enrichment plants are collected by swiping selected areas of the plant with squares of cotton cloth (10x10 cm) from sampling kits prepared in ultra clean condition. The squares of cotton cloth sealed in plastic bags are sent for analysis to the Network Analytical Laboratories. The analysis includes the measurement of the uranium isotopic composition in uranium-containing particles by Thermal lonization Mass Spectroscopy (TIMS) or Secondary ION Mass Spectroscopy (SIMS). Since the implementation of environmental sampling, swipes have been collected from 240 sampling points at three gas centrifuge plants of URENCO, which have a total throughput of more than 8,000 tonnes of uranium per year. The particle analysis results generally reflected the known operational history of the plants and confirmed that they had only been operated to produce uranium with enrichment less than 5% 235 U. The information about the content of the minor isotopes 234 U and 236 U also indicates that depleted and recycled uranium were sometimes used as feed materials in some plants. An example is given of the TIMS particle

  1. Adaptive maximal poisson-disk sampling on surfaces

    KAUST Repository

    Yan, Dongming

    2012-01-01

    In this paper, we study the generation of maximal Poisson-disk sets with varying radii on surfaces. Based on the concepts of power diagram and regular triangulation, we present a geometric analysis of gaps in such disk sets on surfaces, which is the key ingredient of the adaptive maximal Poisson-disk sampling framework. Moreover, we adapt the presented sampling framework for remeshing applications. Several novel and efficient operators are developed for improving the sampling/meshing quality over the state-of-theart. © 2012 ACM.

  2. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, open-quotes Draftclose quotes or open-quotes Verifiedclose quotes. open-quotes Draftclose quotes methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. open-quotes Verifiedclose quotes methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy

  3. DOE methods for evaluating environmental and waste management samples

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K. [eds.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, {open_quotes}Draft{close_quotes} or {open_quotes}Verified{close_quotes}. {open_quotes}Draft{close_quotes} methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. {open_quotes}Verified{close_quotes} methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy.

  4. Effects of XPS operational parameters on investigated sample surfaces

    International Nuclear Information System (INIS)

    Mrad, O.; Ismail, I.

    2013-04-01

    In this work, we studied the effects of the operating conditions of the xray photoelectron spectroscopy analysis technique (XPS) on the investigated samples. Firstly, the performances of the whole system have been verified as well as the accuracy of the analysis. Afterwards, the problem of the analysis of insulating samples caused by the charge buildup on the surface has been studied. The use of low-energy electron beam (<100 eV) to compensate the surface charge has been applied. The effect of X-ray on the samples have been assessed and was found to be nondestructive within the analysis time. The effect of low- and high-energy electron beams on the sample surface have been investigated. Highenergy electrons were found to have destructive effect on organic samples. The sample heating procedure has been tested and its effect on the chemical stat of the surface was followed. Finally, the ion source was used to determine the elements distribution and the chemical stat of different depths of the sample. A method has been proposed to determine these depths (author).

  5. Analysis of the Touch-And-Go Surface Sampling Concept for Comet Sample Return Missions

    Science.gov (United States)

    Mandic, Milan; Acikmese, Behcet; Bayard, David S.; Blackmore, Lars

    2012-01-01

    This paper studies the Touch-and-Go (TAG) concept for enabling a spacecraft to take a sample from the surface of a small primitive body, such as an asteroid or comet. The idea behind the TAG concept is to let the spacecraft descend to the surface, make contact with the surface for several seconds, and then ascend to a safe location. Sampling would be accomplished by an end-effector that is active during the few seconds of surface contact. The TAG event is one of the most critical events in a primitive body sample-return mission. The purpose of this study is to evaluate the dynamic behavior of a representative spacecraft during the TAG event, i.e., immediately prior, during, and after surface contact of the sampler. The study evaluates the sample-collection performance of the proposed sampling end-effector, in this case a brushwheel sampler, while acquiring material from the surface during the contact. A main result of the study is a guidance and control (G&C) validation of the overall TAG concept, in addition to specific contributions to demonstrating the effectiveness of using nonlinear clutch mechanisms in the sampling arm joints, and increasing the length of the sampling arms to improve robustness.

  6. Nuclear analytical techniques and their application to environmental samples

    International Nuclear Information System (INIS)

    Lieser, K.H.

    1986-01-01

    A survey is given on nuclear analytical techniques and their application to environmental samples. Measurement of the inherent radioactivity of elements or radionuclides allows determination of natural radioelements (e.g. Ra), man-made radioelements (e.g. Pu) and radionuclides in the environment. Activation analysis, in particular instrumental neutron activation analysis, is a very reliable and sensitive method for determination of a great number of trace elements in environmental samples, because the most abundant main constituents are not activated. Tracer techniques are very useful for studies of the behaviour and of chemical reactions of trace elements and compounds in the environment. Radioactive sources are mainly applied for excitation of characteristic X-rays (X-ray fluorescence analysis). (author)

  7. Results of tritium measurement in environmental samples and drainage

    International Nuclear Information System (INIS)

    Koike, Ryoji; Hirai, Yasuo

    1983-01-01

    In Ibaraki prefecture, the tritium concentration in the drainage from the nuclear facilities has been measured since 1974. Then, with the start of operation of the fuel reprocessing plant in 1977, the tritium concentration in environmental samples was to be measured also in order to examine the effect of the drainage on the environment. The results of the tritium measurement in Ibaraki prefecture up to about 1980 are described: sampling points, sampling and measuring methods, the tritium concentration in the drainage, air, inland water and seawater, respectively. The drainages have been taken from Japan Atomic Power Company, Japan Atomic Energy Research Institute, and Power Reactor and Nuclear Fuel Development Corporation (with the fuel reprocessing plant). The samples of air, inland water and seawater have been taken in the areas concerned. The tritium concentration was measured by a low-background liquid scintillation counter. The measured values in the environment have been generally at low level, not different from other areas. (Mori, K.)

  8. Spectrophotometric Determination of Boron in Environmental Water Samples

    International Nuclear Information System (INIS)

    San San; Khin Win Kyi; Kwaw Naing

    2002-02-01

    The present paper deals with the study on the methods for the determination of boron in the environmental water samples. The standard methods which are useful for this determination are discussed thoroughly in this work. Among the standard methods approved by American Public Health Association, the carmine method was selected for this study. Prior to the determination of boron in the water samples, the precision and accuracy of the methods of choice were examined by using standard boron solutions. The determination of Boron was carried out by using water samples, waste water from Aquaculture Research Centre, University of Yangon, the Ayeyarwady River water near Magway Myathalon Pagoda in Magway Division, ground water from Sanchaung Township, and tap water from Universities' Research Centre, University of Yangon. Analyses of these water samples were done and statistical treatment of the results was carried out. (author)

  9. Development of environmental sample analysis techniques for safeguards

    International Nuclear Information System (INIS)

    Magara, Masaaki; Hanzawa, Yukiko; Esaka, Fumitaka

    1999-01-01

    JAERI has been developing environmental sample analysis techniques for safeguards and preparing a clean chemistry laboratory with clean rooms. Methods to be developed are a bulk analysis and a particle analysis. In the bulk analysis, Inductively-Coupled Plasma Mass Spectrometer or Thermal Ionization Mass Spectrometer are used to measure nuclear materials after chemical treatment of sample. In the particle analysis, Electron Probe Micro Analyzer and Secondary Ion Mass Spectrometer are used for elemental analysis and isotopic analysis, respectively. The design of the clean chemistry laboratory has been carried out and construction will be completed by the end of March, 2001. (author)

  10. Neutron activation analysis for environmental sample in Thailand

    International Nuclear Information System (INIS)

    Busamongkol, Arporn; Nouchpramool, Sunun; Bunprapob, Supamatthree; Sumitra, Tatchai

    2003-01-01

    Neutron Activation Analysis has been applied for the trace elements analysis in environmental samples. Thirty three samples of airborne particulate were collected every week at Ongkharak Nuclear Research Center (ONRC) during the period of June 1998 to March 1999. The Ti, I, Mg, Na, V, K, Cl, Al, Mn, Ca, As, Sm, Sb, Br, La, Ce, Th, Cr, Cs, Sc, Rb, Fe, Zn and Co were analyzed by Neutron Activation Analysis utilizing 2 MW TRIGA MARK III research reactor. The certified reference materials 1632a and 1633a from National Bureau of Standard were select as standard. (author)

  11. Sample test cases using the environmental computer code NECTAR

    International Nuclear Information System (INIS)

    Ponting, A.C.

    1984-06-01

    This note demonstrates a few of the many different ways in which the environmental computer code NECTAR may be used. Four sample test cases are presented and described to show how NECTAR input data are structured. Edited output is also presented to illustrate the format of the results. Two test cases demonstrate how NECTAR may be used to study radio-isotopes not explicitly included in the code. (U.K.)

  12. Environmental sampling accounting at the Savannah River Plant

    International Nuclear Information System (INIS)

    Zeigler, C.C.; Wood, M.B.

    1978-06-01

    At the Savannah River Plant Environmental Monitoring Laboratories, a computer-based systematic accounting method was developed to ensure that all scheduled samples are collected, processed through the laboratory, and counted without delay. The system employs an IBM 360/195 computer with a magnetic tape master file, an on-line disk file, and cathode ray tube (CRT) terminals. Scheduling and accounting are accomplished by using computer-generated schedules, collection labels, and output/input cards. For each scheduled sample and analysis, a printed card is issued for collection, laboratory analysis, and counting. The cards also contain information needed by personnel performing the jobs, such as sample location, aliquot to be processed, or procedure number. Manual entries are made on the cards when each step in the process is completed. Additional pertinent data are also manually entered on the cards; e.g., entries are made explaining why a sample is not collected, the sample aliquot in the event a nonstandard aliquot is processed, field measurement results, and analytical results. These manually entered data are keypunched and read into the computer files. The computer files are audited daily, and summaries of samples not processed in pre-established normal time intervals are issued. The progress of sample analyses can also be readily determined at any time using the CRT terminal. Historic data are also maintained on magnetic tape and workload summaries are issued showing the number of samples and number of determinations per month

  13. Environmental sampling: Issues for the cut-off regime

    International Nuclear Information System (INIS)

    Fearey, B.L.

    1995-01-01

    The fissile material cut-off treaty (FMCT) initiative under the Conference on Disarmament mandate is envisioned to include certain aspects of environmental sampling and monitoring. One of the intents of this treaty is to bring certain non-NPT signatories (e.g., threshold states) under this treaty agreement along with the nuclear weapon states (NWSs). This paper provides a brief overview of some of the relevant issues that may be involved in the implementation and use of environmental monitoring for (1) verification of the cut-off regime declarations, (2) the detection of undeclared activities, and, (3) application in non-routine inspections. The intent is to provide backstopping information important for treaty negotiators. Specific issues addressed within this paper include signature sampling, differences in the proposed detection regime, potential signature integrators, specific examples and spoofing concerns. Many of these issues must be carefully considered and weighed in order to create a credibly verifiable inspection regime. Importantly, the cut-off treaty must enable nondiscriminatory implementation, while carefully assuring that nonproliferation treaty requirements are maintained (i.e., preventing unintentional release of critical weapons design information--potentially through environmental sampling and analysis)

  14. Transuranium analysis methodologies for biological and environmental samples

    International Nuclear Information System (INIS)

    Wessman, R.A.; Lee, K.D.; Curry, B.; Leventhal, L.

    1978-01-01

    Analytical procedures for the most abundant transuranium nuclides in the environment (i.e., plutonium and, to a lesser extent, americium) are available. There is a lack of procedures for doing sequential analysis for Np, Pu, Am, and Cm in environmental samples, primarily because of current emphasis on Pu and Am. Reprocessing requirements and waste disposal connected with the fuel cycle indicate that neptunium and curium must be considered in environmental radioactive assessments. Therefore it was necessary to develop procedures that determine all four of these radionuclides in the environment. The state of the art of transuranium analysis methodology as applied to environmental samples is discussed relative to different sample sources, such as soil, vegetation, air, water, and animals. Isotope-dilution analysis with 243 Am ( 239 Np) and 236 Pu or 242 Pu radionuclide tracers is used. Americium and curium are analyzed as a group, with 243 Am as the tracer. Sequential extraction procedures employing bis(2-ethyl-hexyl)orthophosphoric acid (HDEHP) were found to result in lower yields and higher Am--Cm fractionation than ion-exchange methods

  15. Analysis of polychlorinated n-alkanes in environmental samples.

    Science.gov (United States)

    Santos, F J; Parera, J; Galceran, M T

    2006-10-01

    Polychlorinated n-alkanes (PCAs), also known as chlorinated paraffins (CPs), are highly complex technical mixtures that contain a huge number of structural isomers, theoretically more than 10,000 diastereomers and enantiomers. As a consequence of their persistence, tendency to bioaccumulation, and widespread and unrestricted use, PCAs have been found in aquatic and terrestrial food webs, even in rural and remote areas. Recently, these compounds have been included in regulatory programs of several international organizations, including the US Environmental Protection Agency and the European Union. Consequently, there is a growing demand for reliable methods with which to analyze PCAs in environmental samples. Here, we review current trends and recent developments in the analysis of PCAs in environmental samples such as air, water, sediment, and biota. Practical aspects of sample preparation, chromatographic separation, and detection are covered, with special emphasis placed on analysis of PCAs using gas chromatography-mass spectrometry. The advantages and limitations of these techniques as well as recent improvements in quantification procedures are discussed.

  16. Intelligent sampling for the measurement of structured surfaces

    International Nuclear Information System (INIS)

    Wang, J; Jiang, X; Blunt, L A; Scott, P J; Leach, R K

    2012-01-01

    Uniform sampling in metrology has known drawbacks such as coherent spectral aliasing and a lack of efficiency in terms of measuring time and data storage. The requirement for intelligent sampling strategies has been outlined over recent years, particularly where the measurement of structured surfaces is concerned. Most of the present research on intelligent sampling has focused on dimensional metrology using coordinate-measuring machines with little reported on the area of surface metrology. In the research reported here, potential intelligent sampling strategies for surface topography measurement of structured surfaces are investigated by using numerical simulation and experimental verification. The methods include the jittered uniform method, low-discrepancy pattern sampling and several adaptive methods which originate from computer graphics, coordinate metrology and previous research by the authors. By combining the use of advanced reconstruction methods and feature-based characterization techniques, the measurement performance of the sampling methods is studied using case studies. The advantages, stability and feasibility of these techniques for practical measurements are discussed. (paper)

  17. A Geostatistical Approach to Indoor Surface Sampling Strategies

    DEFF Research Database (Denmark)

    Schneider, Thomas; Petersen, Ole Holm; Nielsen, Allan Aasbjerg

    1990-01-01

    Particulate surface contamination is of concern in production industries such as food processing, aerospace, electronics and semiconductor manufacturing. There is also an increased awareness that surface contamination should be monitored in industrial hygiene surveys. A conceptual and theoretical...... framework for designing sampling strategies is thus developed. The distribution and spatial correlation of surface contamination can be characterized using concepts from geostatistical science, where spatial applications of statistics is most developed. The theory is summarized and particulate surface...... contamination, sampled from small areas on a table, have been used to illustrate the method. First, the spatial correlation is modelled and the parameters estimated from the data. Next, it is shown how the contamination at positions not measured can be estimated with kriging, a minimum mean square error method...

  18. Transport Powder and Liquid Samples by Surface Acoustic Waves

    Science.gov (United States)

    Bao, Xiaoqi; Bar-Cohen, Yoseph; Sherrit, Stewart; Badescu, Mircea; Louyeh, Sahar

    2009-01-01

    Sample transport is an important requirement for In-situ analysis of samples in NASA planetary exploration missions. Tests have shown that powders or liquid drops on a surface can be transported by surface acoustic waves (SAW) that are generated on the surface using interdigital transducers. The phenomena were investigated experimentally and to generate SAWs interdigital electrodes were deposited on wafers of 128 deg rotated Y-cut LiNbO?. Transporting capability of the SAW device was tested using particles of various sizes and drops of various viscosities liquids. Because of different interaction mechanisms with the SAWs, the powders and the liquid drops were observed to move in opposite directions. In the preliminary tests, a speed of 180 mm/s was achieved for powder transportation. The detailed experimental setup and results are presented in this paper. The transporting mechanism can potentially be applied to miniaturize sample analysis system or " lab-on-chip" devices.

  19. Capacity constrained blue-noise sampling on surfaces

    KAUST Repository

    Zhang, Sen

    2015-11-27

    We present a novel method for high-quality blue-noise sampling on mesh surfaces with prescribed cell-sizes for the underlying tessellation (capacity constraint). Unlike the previous surface sampling approach that only uses capacity constraints as a regularizer of the Centroidal Voronoi Tessellation (CVT) energy, our approach enforces an exact capacity constraint using the restricted power tessellation on surfaces. Our approach is a generalization of the previous 2D blue noise sampling technique using an interleaving optimization framework. We further extend this framework to handle multi-capacity constraints. We compare our approach with several state-of-the-art methods and demonstrate that our results are superior to previous work in terms of preserving the capacity constraints.

  20. Composite sampling of a Bacillus anthracis surrogate with cellulose sponge surface samplers from a nonporous surface.

    Directory of Open Access Journals (Sweden)

    Jenia A M Tufts

    Full Text Available A series of experiments was conducted to explore the utility of composite-based collection of surface samples for the detection of a Bacillus anthracis surrogate using cellulose sponge samplers on a nonporous stainless steel surface. Two composite-based collection approaches were evaluated over a surface area of 3716 cm2 (four separate 929 cm2 areas, larger than the 645 cm2 prescribed by the standard Centers for Disease Control (CDC and Prevention cellulose sponge sampling protocol for use on nonporous surfaces. The CDC method was also compared to a modified protocol where only one surface of the sponge sampler was used for each of the four areas composited. Differences in collection efficiency compared to positive controls and the potential for contaminant transfer for each protocol were assessed. The impact of the loss of wetting buffer from the sponge sampler onto additional surface areas sampled was evaluated. Statistical tests of the results using ANOVA indicate that the collection of composite samples using the modified sampling protocol is comparable to the collection of composite samples using the standard CDC protocol (p  =  0.261. Most of the surface-bound spores are collected on the first sampling pass, suggesting that multiple passes with the sponge sampler over the same surface may be unnecessary. The effect of moisture loss from the sponge sampler on collection efficiency was not significant (p  =  0.720 for both methods. Contaminant transfer occurs with both sampling protocols, but the magnitude of transfer is significantly greater when using the standard protocol than when the modified protocol is used (p<0.001. The results of this study suggest that composite surface sampling, by either method presented here, could successfully be used to increase the surface area sampled per sponge sampler, resulting in reduced sampling times in the field and decreased laboratory processing cost and turn-around times.

  1. Sampling, storage and sample preparation procedures for X ray fluorescence analysis of environmental materials

    International Nuclear Information System (INIS)

    1997-06-01

    X ray fluorescence (XRF) method is one of the most commonly used nuclear analytical technique because of its multielement and non-destructive character, speed, economy and ease of operation. From the point of view of quality assurance practices, sampling and sample preparation procedures are the most crucial steps in all analytical techniques, (including X ray fluorescence) applied for the analysis of heterogeneous materials. This technical document covers recent modes of the X ray fluorescence method and recent developments in sample preparation techniques for the analysis of environmental materials. Refs, figs, tabs

  2. A comparison of some radionuclide contents in environmental samples

    International Nuclear Information System (INIS)

    Shiraishi, Kunio; Muramatsu, Yasuyuki; Nakajima, Toshiyuki; Yamamoto, Masayoshi; Los, I.P.; Kamarikov, I.Yu.; Buzinny, M.G.

    1992-01-01

    Global contamination by radionuclides was likely induced through the Chernobyl nuclear accident in 1986. Environmental samples such as fish, milk, total diet samples etc., collected in Kiev, in the vicinity of Chernobyl, and Mito city, Japan, were analyzed for six selected radionuclides. After samples were dry-ashed, radioactivities of Cs-137, Cs-134, K-40, Co-60, and Mn-54 were determined by gamma-ray spectroscopy with a germanium detector. Strontium-90 was determined by low-background beta-spectrometry after chemical separations by fuming nitric acid. Concentrations of radioactivities in the Kiev samples, in the vicinity of the Chernobyl, are shown below. For comparison, values obtained in Japan, including literature values, are shown in parentheses. Radioactivities in airborne dust were: Sr-90, 63 mBq/m 3 (0.001-0.1); Cs-137, 26 mBg/m 3 (0.001-1); Cs-134, 4 mBq/m 3 ; Co-60, 4 mBq/m 3 ; Mn-54, 2 mBq/m 3 . Radioactivities of milk were as follows; Sr-90, 0.25-1.2 Bq/liter (0.01-0.1); Cs-137, 6-77 Bq/liter (0.01-1); Cs-134, 2-8 Bq/liter. Radioactivities of Sr-90 and Cs-137 for fish (carp), were found to be 3-75 Bq/kg-fresh (0.76-0.98) and 46-2130 Bq/kg-fresh (<0.8), respectively. It was observed that the daily intake of Sr-90 and Cs-137 were 0.25 Bq (0.1) and 0.43 Bq (0.1) per person, respectively. Due to the small number of samples analyzed it is premature to draw a firm conclusion from this study. However, the levels of radionuclides in environmental samples were found to differ between Kiev and Mito with wide ranges depending on the samples. (author)

  3. Environmental sample accounting at the Savannah River Plant

    International Nuclear Information System (INIS)

    Zeigler, C.C.; Wood, M.B.

    1978-01-01

    At the Savannah River Plant Environmental Monitoring Laboratories, a computer-based systematic accounting method was developed to ensure that all scheduled samples are collected, processed through the laboratory, and counted without delay. The system employs an IBM 360/195 computer with a magnetic tape master file, an online disk file, and cathode ray tube (CRT) terminals. Scheduling and accounting are accomplished using computer-generated schedules, bottle labels, and output/ input cards. A printed card is issued for the collecting, analyzing, and counting of each scheduled sample. The card also contains information for the personnel who are to perform the work, e.g., sample location, aliquot to be processed, and procedure to be used. Manual entries are made on the card when each step in the process is completed. Additional pertinent data such as the reason a sample is not collected, the need for a nonstandard aliquot, and field measurement results are keypunched and then read into the computer files as required. The computer files are audited daily and summaries showing samples not processed in pre-established normal schedules are provided. The progress of sample analyses is readily determined at any time using the CRT terminal. Historic data are maintained on magnetic tape, and workload summaries showing the number of samples and number of determinations per month are issued. (author)

  4. May 2011 Groundwater and Surface Water Sampling at the Rio Blanco, Colorado, Site (Data Validation Package)

    International Nuclear Information System (INIS)

    2011-01-01

    Annual sampling was conducted at the Rio Blanco, Colorado, site for the Long-Term Hydrologic Monitoring Program May 16-17, 2011, to monitor groundwater and surface water for potential radionuclide contamination. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for the U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). A duplicate sample was collected from location Johnson Artesian WL. Samples were analyzed by the U.S. Environmental Protection Agency (EPA) Radiation&Indoor Environments National Laboratory in Las Vegas, Nevada. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry, and for tritium using the conventional method. Tritium was not measured using the enrichment method because the EPA laboratory no longer offers that service. Results of this monitoring at the Rio Blanco site demonstrate that groundwater and surface water outside the boundaries have not been affected by project-related contaminants.

  5. Computer simulation of RBS spectra from samples with surface roughness

    Energy Technology Data Exchange (ETDEWEB)

    Malinský, P., E-mail: malinsky@ujf.cas.cz [Nuclear Physics Institute of the Academy of Sciences of the Czech Republic, v. v. i., 250 68 Rez (Czech Republic); Department of Physics, Faculty of Science, J. E. Purkinje University, Ceske mladeze 8, 400 96 Usti nad Labem (Czech Republic); Hnatowicz, V., E-mail: hnatowicz@ujf.cas.cz [Nuclear Physics Institute of the Academy of Sciences of the Czech Republic, v. v. i., 250 68 Rez (Czech Republic); Macková, A., E-mail: mackova@ujf.cas.cz [Nuclear Physics Institute of the Academy of Sciences of the Czech Republic, v. v. i., 250 68 Rez (Czech Republic); Department of Physics, Faculty of Science, J. E. Purkinje University, Ceske mladeze 8, 400 96 Usti nad Labem (Czech Republic)

    2016-03-15

    A fast code for the simulation of common RBS spectra including surface roughness effects has been written and tested on virtual samples comprising either a rough layer deposited on a smooth substrate or smooth layer deposited on a rough substrate and simulated at different geometries. The sample surface or interface relief has been described by a polyline and the simulated RBS spectrum has been obtained as the sum of many particular spectra from randomly chosen particle trajectories. The code includes several procedures generating virtual samples with random and regular (periodical) roughness. The shape of the RBS spectra has been found to change strongly with increasing sample roughness and an increasing angle of the incoming ion beam.

  6. Direct separation of plutonium by thermochromatography from environmental samples

    International Nuclear Information System (INIS)

    Wacker, L.; Kraehenbuehl, U.

    2002-01-01

    A thermochromatographic separation was performed on plutonium from environmental soil samples. This procedure was investigated with the goal to measure low concentrations of plutonium by inductively coupled plasma-mass spectrometry (ICP-MS). The soil sample was chlorinated by thionylchloride as reactive gas at a temperature of 1400 K. The volatile chlorides were separated chromatographically and deposited in a temperature gradient tube filled with quartz grains. Results about the deposition behaviour of the elements were obtained. Two different formalisms based on the thermodynamic functions are used to describe the experimental data. One formula is used to describe the deposition behaviour of microscopic amounts of plutonium (adsorption), the other formula for macroamounts of the main matrix elements (desublimation). The calculated values are in a reasonable agreement with the experimental data. A determination of plutonium content was successfully made for a referenced sea sediment (IAEA-135) after the thermochromatographic sample preparation for ICP-MS. (orig.)

  7. The measure of radiocarbon in the drating of environmental samples

    International Nuclear Information System (INIS)

    Ruiz Pessenda, L.C.; Camargo, P.B. de

    1990-01-01

    An analytical system for radiocarbon dating of environmental samples (charcoal, shell, wood, etc.) using low level liquid scintillation spectrometry has been developed and optimized at Center for Nuclear Energy in Agriculture of the University of Sao Paulo. Physical and chemical pretreatment of samples to remove oils, resins, carbonates and fulvic and humic acids; the benzene synthesis of NBS oxalic acid standard, calcium carbonate P.A. and marble and the results of benzene yield; the optimization of radiocarbon counting window; the effect of scintillators PPO-POPOP and butyl PBD on the efficiency of detection and background of radiocarbon, are described. Samples of charcoal, shell and wood, previously dated at the radiocarbon laboratories of Centre des Faibles Radioactives, France, and Instituto de Geociencias of USP, are analysed for preliminary laboratory intercomparison. (author) [pt

  8. Prospects for the introduction of Wide Area Monitoring Using Environmental Sampling

    International Nuclear Information System (INIS)

    Wogman, N.A.

    2013-01-01

    Nuclear proliferation signatures released to the environment must be collected and distinguished from primordial and man-made backgrounds in soils, sediments, air, and surface and underground water. The delay time between the nuclear proliferation emissions and the date of the Wide-Area Environmental Sampling (WAES) analysis will determine which radionuclides would be analyzed based upon their half-lives. Various sampling and analysis technologies have been considered here for application to a WAES. Sampling procedures and equipment discussed are aimed at aquatic, airborne particulate, gas, vegetation, sediment and/or soil, and fauna media. Specific procedures must be selected based upon the application scenario; for example, sampling in the northern latitudes under freezing conditions, sampling at the equator under tropical rain-forest conditions, sampling in the mid-latitudes under desert conditions, and sampling in the marine environment require different equipment and procedures. The paper is followed by the slides of the presentation

  9. Rapid surface sampling and archival record system (RSSAR)

    International Nuclear Information System (INIS)

    Barren, E.; Bracco, A.; Dorn, S.B.

    1997-01-01

    Purpose is to develop a rapid surface (concrete, steel) contamination measurement system that will provide a ''quick-look'' indication of contamination areas, an archival record, and an automated analysis. A bulk sampling oven is also being developed. The sampling device consists of a sampling head, a quick look detector, and an archiving system (sorbent tube). The head thermally desorbs semi-volatiles, such as PCBs, oils, etc., from concrete and steel surfaces; the volatilized materials are passed through a quick-look detector. Sensitivity of the detector can be attenuated for various contaminant levels. Volatilized materials are trapped in a tube filled with adsorbent. The tubes are housed in a magazine which also archives information about sampling conditions. Analysis of the tubes can be done at a later date. The concrete sampling head is fitted with a tungsten-halogen lamp; in laboratory experiments it has extracted model contaminants by heating the top 4mm of the surface to 250 C within 100-200 s. The steel sampling head has been tested on different types of steels and has extracted model contaminants within 30 s. A mathematical model of heat and mass transport in concrete has been developed. Rate of contaminant removal is at maximum when the moisture content is about 100 kg/m 3 . The system will be useful during decontamination and decommissioning operations

  10. Evaluation of surface sampling method performance for Bacillus Spores on clean and dirty outdoor surfaces.

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Mollye C.; Einfeld, Wayne; Boucher, Raymond M.; Brown, Gary Stephen; Tezak, Matthew Stephen

    2011-06-01

    Recovery of Bacillus atrophaeous spores from grime-treated and clean surfaces was measured in a controlled chamber study to assess sampling method performance. Outdoor surfaces investigated by wipe and vacuum sampling methods included stainless steel, glass, marble and concrete. Bacillus atrophaeous spores were used as a surrogate for Bacillus anthracis spores in this study designed to assess whether grime-coated surfaces significantly affected surface sampling method performance when compared to clean surfaces. A series of chamber tests were carried out in which known amounts of spores were allowed to gravitationally settle onto both clean and dirty surfaces. Reference coupons were co-located with test coupons in all chamber experiments to provide a quantitative measure of initial surface concentrations of spores on all surfaces, thereby allowing sampling recovery calculations. Results from these tests, carried out under both low and high humidity conditions, show that spore recovery from grime-coated surfaces is the same as or better than spore recovery from clean surfaces. Statistically significant differences between method performance for grime-coated and clean surfaces were observed in only about half of the chamber tests conducted.

  11. Environmental data for calendar year 1992: Surface and Columbia River

    International Nuclear Information System (INIS)

    Bisping, L.E.; Woodruff, R.K.

    1993-06-01

    Pacific Northwest Laboratory publishes an annual environmental report for the Hanford Site each calendar year. The Hanford Site Environmental Report for Calendar Year 1992 describes the Site mission and activities, general environmental features, radiological and chemical releases from operations, status of compliance with environmental regulations, status of programs to accomplish compliance, and environmental monitoring activities and results. The report includes a summary of offsite and onsite environmental monitoring data collected during 1992 by PNL's Environmental Monitoring Program. Appendix A of that report contains data summaries created from raw surface and river monitoring data. This volume contains the actual raw data used to create the summaries. Ground-water monitoring data are available in a separate volume (Hanford Site Environmental Data for Calendar Year 1992--Ground Water)

  12. Environmental data for calendar year 1992: Surface and Columbia River

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.; Woodruff, R.K.

    1993-06-01

    Pacific Northwest Laboratory publishes an annual environmental report for the Hanford Site each calendar year. The Hanford Site Environmental Report for Calendar Year 1992 describes the Site mission and activities, general environmental features, radiological and chemical releases from operations, status of compliance with environmental regulations, status of programs to accomplish compliance, and environmental monitoring activities and results. The report includes a summary of offsite and onsite environmental monitoring data collected during 1992 by PNL`s Environmental Monitoring Program. Appendix A of that report contains data summaries created from raw surface and river monitoring data. This volume contains the actual raw data used to create the summaries. Ground-water monitoring data are available in a separate volume (Hanford Site Environmental Data for Calendar Year 1992--Ground Water).

  13. Hanford Environmental Monitoring Program schedule for samples, analyses, and measurements for calendar year 1985

    International Nuclear Information System (INIS)

    Blumer, P.J.; Price, K.R.; Eddy, P.A.; Carlile, J.M.V.

    1984-12-01

    This report provides the CY 1985 schedule of data collection for the routine Hanford Surface Environmental Monitoring and Ground-Water Monitoring Programs at the Hanford Site. The purpose is to evaluate and report the levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5484.1. The routine sampling schedule provided herein does not include samples scheduled to be collected during FY 1985 in support of special studies, special contractor support programs, or for quality control purposes. In addition, the routine program outlined in this schedule is subject to modification during the year in response to changes in site operations, program requirements, or unusual sample results

  14. Potential Use of Passive Sampling for Environmental Monitoring of Petroleum E&P Operations

    Science.gov (United States)

    Traditional environmental monitoring relies on water or soil samples being taken at various time increments and sent to offsite laboratories for analysis. Reliance on grab samples generally captures limited “snapshots” of environmental contaminant concentrations, is time intensive, costly, and generates residual waste from excess sample and/or reagents used in the analysis procedures. As an alternative, we are evaluating swellable organosilica sorbents to create passive sampling systems for monitoring applications. Previous work has focused on absorption and detection of fuels, chlorinated solvents, endocrine disruptors, explosives, pesticides, fluorinated chemicals, and metals including Ba, Sr, Hg, Pb, Fe, Cu, and Zn. The advantages of swellable organosilica are that the material cancapture target compounds for an extended periods of time, does not absorb natural organic matter, and resists biofilm formation since the sorbent possesses an animated surface morphology.

  15. Appendix to Health and Safety Laboratory environmental quarterly, March 1, 1976--June 1, 1976. [Tabulated data on content of lead in surface air and /sup 7/Be, /sup 95/Zr, /sup 137/Cs, /sup 144/Ce, and /sup 90/Sr in surface air, milk, drinking water, and foods sampled in USA

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, E.P. Jr.

    1976-07-01

    Tabulated data are presented on: the monthly deposition of /sup 89/Sr and /sup 90/Sr at some 100 world land sites; the content of lead and /sup 7/Be, /sup 95/Zr, /sup 137/Cs, and /sup 144/Ce in samples of surface air from various world sites; and the content of /sup 90/Sr in samples of milk, drinking water, and animal and human diets collected at various locations throughout the USA. (CH)

  16. Use of immunomagnetic separation for the detection of Desulfovibrio vulgaris from environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, R.; Hazen, T.C.; Joyner, D.C.; Kusel, K.; Singer, M.E.; Sitte, J.; Torok, T.

    2011-04-15

    Immunomagnetic separation (IMS) has proved highly efficient for recovering microorganisms from heterogeneous samples. Current investigation targeted the separation of viable cells of the sulfate-reducing bacterium, Desulfovibrio vulgaris. Streptavidin-coupled paramagnetic beads and biotin labeled antibodies raised against surface antigens of this microorganism were used to capture D. vulgaris cells in both bioreactor grown laboratory samples and from extremely low-biomass environmental soil and subsurface drilling samples. Initial studies on detection, recovery efficiency and viability for IMS were performed with laboratory grown D. vulgaris cells using various cell densities. Efficiency of cell isolation and recovery (i.e., release of the microbial cells from the beads following separation) was followed by microscopic imaging and acridine orange direct counts (AODC). Excellent recovery efficiency encouraged the use of IMS to capture Desulfovibrio spp. cells from low-biomass environmental samples. The environmental samples were obtained from a radionuclide-contaminated site in Germany and the chromium (VI)-contaminated Hanford site, an ongoing bioremediation project of the U.S. Department of Energy. Field deployable IMS technology may greatly facilitate environmental sampling and bioremediation process monitoring and enable transcriptomics and proteomics/metabolomics-based studies directly on cells collected from the field.

  17. Benthic foraminiferal census data from Mobile Bay, Alabama--counts of surface samples and box cores

    Science.gov (United States)

    Richwine, Kathryn A.; Osterman, Lisa E.

    2012-01-01

    A study was undertaken in order to understand recent environmental change in Mobile Bay, Alabama. For this study a series of surface sediment and box core samples was collected. The surface benthic foraminiferal data provide the modern baseline conditions of the bay and can be used as a reference for changing paleoenvironmental parameters recorded in the box cores. The 14 sampling locations were chosen in the bay to cover the wide diversity of fluvial and marine-influenced environments on both sides of the shipping channel.

  18. Hydrogen and fluorine in the surfaces of lunar samples

    International Nuclear Information System (INIS)

    Leich, D.A.; Goldberg, R.H.; Burnett, D.S.; Tombrello, T.A.

    1974-04-01

    The resonant nuclear reaction F-19 (p, alpha gamma)O-16 was used to perform depth sensitive analyses for both fluorine and hydrogen in lunar samples. The resonance at 0.83 MeV (center-of-mass) in this reaction was applied to the measurement of the distribution of trapped solar protons in lunar samples to depths of about 1 / 2 micrometer. These results are interpreted in terms of terrestrial H 2 O surface contamination and a redistribution of the implanted solar H which has been influenced by heavy radiation damage in the surface region. Results are also presented for an experiment to test the penetration of H 2 O into laboratory glass samples which have been irradiated with O-16 to simulate the radiation damaged surfaces of lunar glasses. Fluorine determinations were performed in a 1 pm surface layer on lunar samples using the same F-19(alpha gamma)O-16 resonance. The data are discussed from the standpoint of lunar fluorine and Teflon contamination. (U.S.)

  19. Near surface spent fuel storage: environmental issues

    International Nuclear Information System (INIS)

    Nelson, I.C.; Shipler, D.B.; McKee, R.W.; Glenn, R.D.

    1979-01-01

    Interim storage of spent fuel appears inevitable because of the lack of reprocessing plants and spent fuel repositories. This paper examines the environmental issues potentially associated with management of spent fuel before disposal or reprocessing in a reference scenario. The radiological impacts of spent fuel storage are limited to low-level releases of noble gases and iodine. Water needed for water basin storage of spent fuel and transportation accidents are considered; the need to minimize the distance travelled is pointed out. Resource commitments for construction of the storage facilities are analyzed

  20. Middlesex Sampling Plant: Annual environmental report for calendar year 1990, Middlesex, New Jersey

    International Nuclear Information System (INIS)

    1991-09-01

    Environmental monitoring of the US Department of Energy's (DOE) Middlesex Sampling Plant (MSP) and surrounding area began in 1980. MSP is part of the Formerly Utilized Sites Remedial Action Program (FUSRAP), a DOE program to decontaminate or otherwise control sites where residual radioactive materials remain from the early years of the nation's atomic energy program or from commercial operations causing conditions that Congress has authorized DOE to remedy. The environmental monitoring program at MSP includes sampling networks for radon concentrations in air; external gamma radiation exposure; and radium-226, thorium-232, and total uranium concentrations in surface water, sediment, and groundwater. Additionally, several nonradiological parameters were measured in groundwater, surface water, and sediment. 14 refs., 17 figs., 29 tabs

  1. Stability of metal ions in aqueous environmental samples

    International Nuclear Information System (INIS)

    Rattonetti, A.

    1976-01-01

    The time lapse between the collection of aqueous environmental samples and the analysis affects the original ionic concentration. Studies have proven the nonionic species in a water sample have more of an effect on the veracity of an analysis than the ''container wall'' effect, and that adjustment to a pH of 2 at sample collection time is a ''Pyrrhic victory.'' Lead, for example, will commonly increase an order of magnitude when unfiltered samples are adjusted to a pH of 2 upon collection. This effect is greatest when elemental ions are present in the ng ml -1 range and lessens as the original ionic concentration increases. Data are presented that behooves filtration of stream water and rainwater samples prior to any acidification step. The need to acidify the resulting filtrate is also discussed. Lithium, sodium, potassium, cesium, magnesium, calcium, strontium, manganese, iron, copper, silver, zinc, cadmium, aluminum, indium, and lead are examined. The insoluble phase retained on the filter can be digested with acid and also analyzed. The separate analysis of the filtrate and filter will give a true representation of the occurrence of these metals in nature. Flame and flameless atomic aborption and emission are used to perform the trace analyses

  2. Molecular Identification of Gambierdiscus and Fukuyoa (Dinophyceae from Environmental Samples

    Directory of Open Access Journals (Sweden)

    Kirsty F. Smith

    2017-08-01

    Full Text Available Ciguatera Fish Poisoning (CFP is increasing across the Pacific and the distribution of the causative dinoflagellates appears to be expanding. Subtle differences in thecal plate morphology are used to distinguish dinoflagellate species, which are difficult to determine using light microscopy. For these reasons we sought to develop a Quantitative PCR assay that would detect all species from both Gambierdiscus and Fukuyoa genera in order to rapidly screen environmental samples for potentially toxic species. Additionally, a specific assay for F. paulensis was developed as this species is of concern in New Zealand coastal waters. Using the assays we analyzed 31 samples from three locations around New Zealand and the Kingdom of Tonga. Fourteen samples in total were positive for Gambierdiscus/Fukuyoa and two samples were also positive using the F. paulensis assay. Samples from the Kermadec Islands were further characterized using high-throughput sequencing metabarcoding. The majority of reads corresponded to Gambierdiscus species with three species identified at all sites (G. australes, G. honu and G. polynesiensis. This is the first confirmed identification of G. polynesiensis, a known ciguatoxin producer, in New Zealand waters. Other known toxin-producing genera were also detected, included Alexandrium, Amphidinium, Azadinium, Dinophysis, Ostreopsis, and Prorocentrum.

  3. Nonactivation interaction techniques in the analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.

    1986-01-01

    Nonactivation interaction analytical methods are based on the interaction processes of nuclear and X-ray radiation with a sample, leading to their absorption and backscattering, to the ionization of gases or excitation of fluorescent X-ray by radiation, but not to the activation of determined elements. From the point of view of environmental analysis, the most useful nonactivation interaction techniques are X-ray fluorescence by photon or charged particle excitation, ionization of gases by nuclear radiation, elastic scattering of charged particles and backscattering of beta radiation. The significant advantage of these methods is that they are nondestructive. (author)

  4. Concentration and speciation of radionuclides in environmental samples

    International Nuclear Information System (INIS)

    Testa, C.; Desideri, D.; Meli, M.A.; Roselli, C.

    2000-01-01

    The paper will describe three examples dealing with the measure of some natural (U, Th, 2 10Pb, 4 0K) and artificial ( 1 37Cs, 9 0Sr, 2 39 +2 40Pu, 2 41Am) radionuclides in environmental samples such as mosses, sediments, soils. Extraction chromatography, liquid extraction, selective precipitation and electroplating were used to isolate the radionuclides, except for gamma emitters which were detected by gamma spectrometry. Alpha spectrometry were used to measure the alpha emitters and low background beta detector to measure the beta emitters

  5. Spectrophotometric determination of vanadium in environmental and biological samples

    International Nuclear Information System (INIS)

    Rekha, D.; Krishnapriya, B.; Subrahmanyam, P.; Reddyprasad, P.; Dilip Kumar, J.; Chiranjeevi, P.

    2007-01-01

    The method is based on oxidation of p-nitro aniline by vanadium (V) followed by coupling reaction with N-(1-naphthalene-1-y1)ethane-1, 2-diaminedihydrochloride (NEDA) in basic medium of pH 8 to give purple colored derivative. The derivative having an λ max 525nm is stable for 10 days. Beer's law is obeyed for vanadium (V) in the concentration range of 0.03-4.5 μg ml -1 . The proposed method was successfully applied to the analysis of vanadium in environmental and biological samples. (author)

  6. Stability of volatile organics in environmental soil samples. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Maskarinec, M.P.; Bayne, C.K.; Jenkins, R.A.; Johnson, L.H.; Holladay, S.K.

    1992-11-01

    This report focuses on data generated for the purpose of establishing the stability of 19 volatile organic compounds in environmental soil samples. The study was carried out over a 56 day (for two soils) and a 111 day (for one reference soil) time frame and took into account as many variables as possible within the constraints of budget and time. The objectives of the study were: 1) to provide a data base which could be used to provide guidance on pre-analytical holding times for regulatory purposes; and 2) to provide a basis for the evaluation of data which is generated outside of the currently allowable holding times.

  7. Stability of volatile organics in environmental soil samples

    Energy Technology Data Exchange (ETDEWEB)

    Maskarinec, M.P.; Bayne, C.K.; Jenkins, R.A.; Johnson, L.H.; Holladay, S.K.

    1992-11-01

    This report focuses on data generated for the purpose of establishing the stability of 19 volatile organic compounds in environmental soil samples. The study was carried out over a 56 day (for two soils) and a 111 day (for one reference soil) time frame and took into account as many variables as possible within the constraints of budget and time. The objectives of the study were: 1) to provide a data base which could be used to provide guidance on pre-analytical holding times for regulatory purposes; and 2) to provide a basis for the evaluation of data which is generated outside of the currently allowable holding times.

  8. Sampling and measurement of long-lived radionuclides in environmental samples

    International Nuclear Information System (INIS)

    Brauer, F.P.; Goles, R.W.; Kaye, J.H.; Rieck, H.G. Jr.

    1977-01-01

    The volatile and semivolatile long-lived man-made radionuclides 3 H, 14 C, 79 Se, 85 Kr, 99 Tc, 129 I, 135 Cs, and 137 Cs are of concern in operation of nuclear facilities because they are difficult and expensive to contain and once emitted to the environment they become permanent ecological constituents with both local and global distributions. Species-selective sampling and analytical methods (radiochemical, neutron activation, and mass spectrometric) have been developed for many of these nuclides with sensitivities well below those required for radiation protection. These sampling and analytical methods have been applied to the measurement of current environmental levels of some of the more ecologically important radionuclides. The detection and tracing of long-lived radionuclides is being conducted in order to establish base-line values and to study environmental behavior. This paper describes detection and measurement techniques and summarizes current measurement results

  9. Detection of iodine-129 in some environmental samples

    International Nuclear Information System (INIS)

    Ikeda, Nagao

    1981-01-01

    The recent accumulation of the long-lived isotope of iodine, 129 I, which is released in environment by the peaceful use of nuclear energy or nuclear test explosion is becoming important in the view point of the internal exposure by the low level radiation. The studies on the detection of determination of 129 I in environmental samples so far published are still very few. The authors tried to detect 129 I in some Japanese seaweeds and soil samples with the aid of the activation method by using the nuclear reaction of 129 I(n, #betta#) 130 I. The samples analysed in this work are tangle (Laminaria japonica) for daily food grown in Hidaka, Hokkaido and uncultivated soil collected in Tokai, Ibaraki Pref. As the #betta#-ray peak indicator for 130 I, cesium oxide and the aged radioisotope product of 131 I are also subjected to the neutron irradiation. From cesium oxide, 130 I is formed by the reaction of 133 Cs(n, α) 130 I. An aged vial of the 131 I product is expected to contain very minute amounts of 129 I which is also produced both by the fission of uranium and neutron capture reaction of tellurium followed by #betta# - -decay. The #betta#-ray spectra for the soil sample, cesium oxide and the aged 131 I vial are shown in Fig. 1. No appreciable peak was found for the seaweeds sample. In the #betta#-ray spectra for irradiated cesium oxide and the aged 131 I vial, several typical peaks for 130 I were observed. By comparing with these peaks, several small peaks which appear at around 418, 536 and 739 keV in the soil sample can be attributed to those of 130 I. The 129 I content in the soil sample is roughly estimated to be 2 x 10 - 10 Bq/g. (author)

  10. Optimization of sampling for the determination of the mean Radium-226 concentration in surface soil

    International Nuclear Information System (INIS)

    Williams, L.R.; Leggett, R.W.; Espegren, M.L.; Little, C.A.

    1987-08-01

    This report describes a field experiment that identifies an optimal method for determination of compliance with the US Environmental Protection Agency's Ra-226 guidelines for soil. The primary goals were to establish practical levels of accuracy and precision in estimating the mean Ra-226 concentration of surface soil in a small contaminated region; to obtain empirical information on composite vs. individual soil sampling and on random vs. uniformly spaced sampling; and to examine the practicality of using gamma measurements in predicting the average surface radium concentration and in estimating the number of soil samples required to obtain a given level of accuracy and precision. Numerous soil samples were collected on each six sites known to be contaminated with uranium mill tailings. Three types of samples were collected on each site: 10-composite samples, 20-composite samples, and individual or post hole samples; 10-composite sampling is the method of choice because it yields a given level of accuracy and precision for the least cost. Gamma measurements can be used to reduce surface soil sampling on some sites. 2 refs., 5 figs., 7 tabs

  11. An Environmentally Friendly, Cost-Effective Determination of Lead in Environmental Samples Using Anodic Stripping Voltammetry

    Science.gov (United States)

    Goldcamp, Michael J.; Underwood, Melinda N.; Cloud, Joshua L.; Harshman, Sean

    2008-01-01

    Contamination of the environment with heavy metals such as lead presents many health risks. Simple, effective, and field-portable methods for the measurement of toxic metals in environmental samples are vital tools for evaluating the risks that these contaminants pose. This article describes the use of new developments in anodic stripping…

  12. Determination of 241Am and 244Cm in environmental samples

    International Nuclear Information System (INIS)

    Bonino, N.O.; Grinman, A.D.R.; Serdeiro, N.H.

    1998-01-01

    The present technique describes a method to separate, purify and measure low levels of americium and curium in different environmental samples such as sediments, soils, water, vegetables, and air filters. The determination of radionuclides in theses environmental matrices have analytical problems, since a simple method doesn't exist for the purification, which is indispensable for its later measuring alpha spectrometry. The developed technique consist on taking an aliquot of the sample to analyze, to add tracer as americium 243 and curium 242, and to dissolve the matrix in a such way to have a clear solution. For the isolation of the americium and curium of the other actinides ar used as separation techniques: precipitation with Fe 3+ , anionic and cationic exchange, and extraction with a appropriate organic solvent. The purification of the americium and curium is followed by the electrodeposition habitually used. The measurement is carried out by alpha spectrometry with a detector of implanted ion. The detection limit for this techniques is of 0,002 Bq/l or 0,2 mBq in the case of filters. (author)

  13. Environmental impact assessment for surface coal mine - a case study

    International Nuclear Information System (INIS)

    Sen, P.; Chakraborty, K.

    1994-01-01

    Surface coal mines being the largest contributor to the national coal production, the study of environmental impacts due to this becomes mandatory as it will help in proper planning and safe operations of the mine in an environmentally compatible manner. Within the scope of this paper, a model for preparation of comprehensive environmental impact assessment (EIA) by utilising a new evaluation methodology leading to determination of Environmental Quality Designation an index has been developed and this model has been validated by using data from a running surface coal mine in Wardha Valley Coalfield. Based on this exercise, the overall impact of the surface coal mine under consideration on environment indicates a medium level and accordingly the control measures have to be planned. Thus repair to the environment has to be made a concurrent activity with mining i.e. to say we have to design with nature not against it

  14. Sampling free energy surfaces as slices by combining umbrella sampling and metadynamics.

    Science.gov (United States)

    Awasthi, Shalini; Kapil, Venkat; Nair, Nisanth N

    2016-06-15

    Metadynamics (MTD) is a very powerful technique to sample high-dimensional free energy landscapes, and due to its self-guiding property, the method has been successful in studying complex reactions and conformational changes. MTD sampling is based on filling the free energy basins by biasing potentials and thus for cases with flat, broad, and unbound free energy wells, the computational time to sample them becomes very large. To alleviate this problem, we combine the standard Umbrella Sampling (US) technique with MTD to sample orthogonal collective variables (CVs) in a simultaneous way. Within this scheme, we construct the equilibrium distribution of CVs from biased distributions obtained from independent MTD simulations with umbrella potentials. Reweighting is carried out by a procedure that combines US reweighting and Tiwary-Parrinello MTD reweighting within the Weighted Histogram Analysis Method (WHAM). The approach is ideal for a controlled sampling of a CV in a MTD simulation, making it computationally efficient in sampling flat, broad, and unbound free energy surfaces. This technique also allows for a distributed sampling of a high-dimensional free energy surface, further increasing the computational efficiency in sampling. We demonstrate the application of this technique in sampling high-dimensional surface for various chemical reactions using ab initio and QM/MM hybrid molecular dynamics simulations. Further, to carry out MTD bias reweighting for computing forward reaction barriers in ab initio or QM/MM simulations, we propose a computationally affordable approach that does not require recrossing trajectories. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. 135Cs/137Cs isotopic composition of environmental samples across Europe: Environmental transport and source term emission applications

    International Nuclear Information System (INIS)

    Snow, Mathew S.; Snyder, Darin C.

    2016-01-01

    135 Cs/ 137 Cs isotopic analyses represent an important tool for studying the fate and transport of radiocesium in the environment; in this work the 135 Cs/ 137 Cs isotopic composition in environmental samples taken from across Europe is reported. Surface soil and vegetation samples from western Russia, Ukraine, Austria, and Hungary show consistent aged thermal fission product 135 Cs/ 137 Cs isotope ratios of 0.58 ± 0.01 (age corrected to 1/1/15), with the exception of one sample of soil-moss from Hungary which shows an elevated 135 Cs/ 137 Cs ratio of 1.78 ± 0.12. With the exception of the outlier sample from Hungary, surface soil/vegetation data are in quantitative agreement with values previously reported for soils within the Chernobyl exclusion zone, suggesting that radiocesium at these locations is primarily composed of homogenous airborne deposition from Chernobyl. Seawater samples taken from the Irish Sea show 135 Cs/ 137 Cs isotope ratios of 1.22 ± 0.11 (age corrected to 1/1/15), suggesting aged thermal fission product Cs discharged from Sellafield. The differences in 135 Cs/ 137 Cs isotope ratios between Sellafield, Chernobyl, and global nuclear weapons testing fallout indicate that 135 Cs/ 137 Cs isotope ratios can be utilized to discriminate between and track radiocesium transport from different nuclear production source terms, including major emission sources in Europe. - Highlights: • 135 Cs/ 137 Cs useful for tracking anthropogenic environmental radiocesium releases. • European surface soils/vegetation have uniform ratio consistent with Chernobyl. • 135 Cs/ 137 Cs in Irish sea represents thermal fission ratio distinct from Chernobyl. • Can distinguish between major source terms in Europe based on 135 Cs/ 137 Cs.

  16. INTERACTION OF IMPULSE ELECTROMAGNETIC FIELDS WITH SURFACES OF METAL SAMPLES

    Directory of Open Access Journals (Sweden)

    V. V. Pavliouchenko

    2006-01-01

    Full Text Available Measurements of maximum tangential component of magnetic intensity Hτm have been carried out in the paper. The measurements have been taken on the surface of metal samples according to time of single current pulse rise in the form of semi-sinusoid of a linear current wire. Measurements have been made with the purpose to determine a value of the component according to thickness of samples made of aluminium.Temporary resolution ranges of electric and magnetic properties and defects of sample continuity along the depth have been found.Empirical formulae of dependence Hτm on sample thickness have been derived and their relation with efficient depth penetration of magnetic field into metal has been found.

  17. Comparison of Antemortem and Environmental Samples for Zebrafish Health Monitoring and Quarantine

    Science.gov (United States)

    Crim, Marcus J; Lawrence, Christian; Livingston, Robert S; Rakitin, Andrei; Hurley, Shane J; Riley, Lela K

    2017-01-01

    Molecular diagnostic assays offer both exquisite sensitivity and the ability to test a wide variety of sample types. Various types of environmental sample, such as detritus and concentrated water, might provide a useful adjunct to sentinels in routine zebrafish health monitoring. Similarly, antemortem sampling would be advantageous for expediting zebrafish quarantine, without euthanasia of valuable fish. We evaluated the detection of Mycobacterium chelonae, M. fortuitum, M. peregrinum, Pseudocapillaria tomentosa, and Pseudoloma neurophilia in zebrafish, detritus, pooled feces, and filter membranes after filtration of 1000-, 500-, and 150-mL water samples by real-time PCR analysis. Sensitivity varied according to sample type and pathogen, and environmental sampling was significantly more sensitive than zebrafish sampling for detecting Mycobacterium spp. but not for Pseudocapillaria neurophilia or Pseudoloma tomentosa. The results of these experiments provide strong evidence of the utility of multiple sample types for detecting pathogens according to each pathogen's life cycle and ecological niche within zebrafish systems. In a separate experiment, zebrafish subclinically infected with M. chelonae, M. marinum, Pleistophora hyphessobryconis, Pseudocapillaria tomentosa, or Pseudoloma neurophilia were pair-spawned and individually tested with subsets of embryos from each clutch that received no rinse, a fluidizing rinse, or were surface-disinfected with sodium hypochlorite. Frequently, one or both parents were subclinically infected with pathogen(s) that were not detected in any embryo subset. Therefore, negative results from embryo samples may not reflect the health status of the parent zebrafish. PMID:28724491

  18. Adventitious Carbon on Primary Sample Containment Metal Surfaces

    Science.gov (United States)

    Calaway, M. J.; Fries, M. D.

    2015-01-01

    Future missions that return astromaterials with trace carbonaceous signatures will require strict protocols for reducing and controlling terrestrial carbon contamination. Adventitious carbon (AC) on primary sample containers and related hardware is an important source of that contamination. AC is a thin film layer or heterogeneously dispersed carbonaceous material that naturally accrues from the environment on the surface of atmospheric exposed metal parts. To test basic cleaning techniques for AC control, metal surfaces commonly used for flight hardware and curating astromaterials at JSC were cleaned using a basic cleaning protocol and characterized for AC residue. Two electropolished stainless steel 316L (SS- 316L) and two Al 6061 (Al-6061) test coupons (2.5 cm diameter by 0.3 cm thick) were subjected to precision cleaning in the JSC Genesis ISO class 4 cleanroom Precision Cleaning Laboratory. Afterwards, the samples were analyzed by X-ray photoelectron spectroscopy (XPS) and Raman spectroscopy.

  19. Carbapenem-Resistant Acinetobacter baumannii: Concomitant Contamination of Air and Environmental Surfaces.

    Science.gov (United States)

    Shimose, Luis A; Masuda, Eriko; Sfeir, Maroun; Berbel Caban, Ana; Bueno, Maria X; dePascale, Dennise; Spychala, Caressa N; Cleary, Timothy; Namias, Nicholas; Kett, Daniel H; Doi, Yohei; Munoz-Price, L Silvia

    2016-07-01

    OBJECTIVE To concomitantly determine the differential degrees of air and environmental contamination by Acinetobacter baumannii based on anatomic source of colonization and type of ICU layout (single-occupancy vs open layout). DESIGN Longitudinal prospective surveillance study of air and environmental surfaces in patient rooms. SETTING A 1,500-bed public teaching hospital in Miami, Florida. PATIENTS Consecutive A. baumannii-colonized patients admitted to our ICUs between October 2013 and February 2014. METHODS Air and environmental surfaces of the rooms of A. baumannii-colonized patients were sampled daily for up to 10 days. Pulsed-field gel electrophoresis (PFGE) was used to type and match the matching air, environmental, and clinical A. baumannii isolates. RESULTS A total of 25 A. baumannii-colonized patients were identified during the study period; 17 were colonized in the respiratory tract and 8 were colonized in the rectum. In rooms with rectally colonized patients, 38.3% of air samples were positive for A. baumannii; in rooms of patients with respiratory colonization, 13.1% of air samples were positive (P=.0001). In rooms with rectally colonized patients, 15.5% of environmental samples were positive for A. baumannii; in rooms of patients with respiratory colonization, 9.5% of environmental samples were positive (P=.02). The rates of air contamination in the open-layout and single-occupancy ICUs were 17.9% and 21.8%, respectively (P=.5). Environmental surfaces were positive in 9.5% of instances in open-layout ICUs versus 13.4% in single-occupancy ICUs (P=.09). CONCLUSIONS Air and environmental surface contaminations were significantly greater among rectally colonized patients; however, ICU layout did not influence the rate of contamination. Infect Control Hosp Epidemiol 2016;37:777-781.

  20. Evaluation of environmental samples containing heavy hydrocarbon components in environmental forensic investigations

    Energy Technology Data Exchange (ETDEWEB)

    Raia, J.C.; Blakley, C.R.; Fuex, A.N.; Villalanti, D.C.; Fahrenthold, P.D. [Triton Anal Corp, Houston, TX (United States)

    2004-03-01

    This article presents a procedure to evaluate and characterize environmental samples containing mixtures of hydrocarbons over a wide boiling range of materials that include fuels and other products used in commerce. The range of the method extends to the higher boiling and heavier molecular weight hydrocarbon products in the range of motor oil, bunker fuel, and heavier residue materials. The procedure uses the analytical laboratory technique of high-temperature simulated distillation along with mathematical regression of the analytical data to estimate the relative contribution of individual products in mixtures of hydrocarbons present in environmental samples. An analytical technique to determine hydrocarbon-type distributions by gas chromatography-mass spectrometry with nitric oxide ionization spectrometry evaluation is also presented. This type of analysis allows complex hydrocarbon mixtures to be classified by their chemical composition, or types of hydrocarbons that include paraffins, cycloparaffins, monoaromatics, and polycyclic aromatic hydrocarbons. Characteristic hydrocarbon patterns for example, in the relative distribution of polycyclic aromatic hydrocarbons are valuable for determining the potential origin of materials present in environmental samples. These methods provide quantitative data for hydrocarbon components in mixtures as a function of boiling range and 'hydrocarbon fingerprints' of the types of materials present. This information is valuable in assessing environmental impacts of hydrocarbons at contaminated sites and establishing the liabilities and cost allocations for responsible parties.

  1. Separation Techniques for Quantification of Radionuclides in Environmental Samples

    Directory of Open Access Journals (Sweden)

    Dusan Galanda

    2009-01-01

    Full Text Available The reliable and quantitative measurement of radionuclides is important in order to determine environmental quality and radiation safety, and to monitor regulatory compliance. We examined soil samples from Podunajske Biskupice, near the city of Bratislava in the Slovak Republic, for the presence of several natural (238U, 232Th, 40K and anthropogenic (137Cs, 90Sr, 239Pu, 240Pu, 241Am radionuclides. The area is adjacent to a refinery and hazardous waste processing center, as well as the municipal incinerator plant, and so might possess an unusually high level of ecotoxic metals. We found that the levels of both naturally occurring and anthropogenic radionuclides fell within the expected ranges, indicating that these facilities pose no radiological threat to the local environment. During the course of our analysis, we modified existing techniques in order to allow us to handle the unusually large and complex samples that were needed to determine the levels of 239Pu, 240Pu, and 241Am activity. We also rated three commercial techniques for the separation of 90Sr from aqueous solutions and found that two of them, AnaLig Sr-01 and Empore Extraction Disks, were suitable for the quantitative and reliable separation of 90Sr, while the third, Sr-Spec Resin, was less so. The main criterion in evaluating these methods was the chemical recovery of 90Sr, which was less than we had expected. We also considered speed of separation and additional steps needed to prepare the sample for separation.

  2. Radioactive contamination of the environmental samples in Hanoi in 1989

    International Nuclear Information System (INIS)

    Dang Huy Uyen; Bui Van Loat; Dang Phuong Nam; Cao Anh Duc; Pham Quang Dien; Nguyen Hao Quang

    1990-01-01

    More than 30 environmental samples from soil, paddy, rice, fruits, vegetables and beans, sesame, tea, bananas, fishes at Hanoi markets in 1989 were analysed by gamma ray spectrometry with the low background system for studying natural and artificial radioactive elements. Among several samples from Hanoi in such kind as cultivated soils, tea, dried bamboo shoots, isotope Cs 137 that used be generated from nuclear explosives was found with contents (30 - 1000) x 10 -5 Bq/g; Cs 137 contents in Japanese rice (0.4 - 3) x 10 -5 Bq/g. Cs 137 is radioactive so Cs 137 contents in Vietnamese rice are 300 times higher than Cs 137 contents in Japanese rice but they are hundred times lower than international standard. Among vegetables, fruits, shrimps, fishes in Hanoi markets, artificial isotopes were not found and natural isotopes were few. Even radioactive daughter and granddaughter in uranium series in potatoes were not found. In some samples K 40 was also appeared, for example in cultivated soils (0.78 Bq/g), in dried bamboo shoots (0.73 Bq/g). (author). 2 refs., 3 figs

  3. Comparison of DNA preservation methods for environmental bacterial community samples.

    Science.gov (United States)

    Gray, Michael A; Pratte, Zoe A; Kellogg, Christina A

    2013-02-01

    Field collections of environmental samples, for example corals, for molecular microbial analyses present distinct challenges. The lack of laboratory facilities in remote locations is common, and preservation of microbial community DNA for later study is critical. A particular challenge is keeping samples frozen in transit. Five nucleic acid preservation methods that do not require cold storage were compared for effectiveness over time and ease of use. Mixed microbial communities of known composition were created and preserved by DNAgard(™), RNAlater(®), DMSO-EDTA-salt (DESS), FTA(®) cards, and FTA Elute(®) cards. Automated ribosomal intergenic spacer analysis and clone libraries were used to detect specific changes in the faux communities over weeks and months of storage. A previously known bias in FTA(®) cards that results in lower recovery of pure cultures of Gram-positive bacteria was also detected in mixed community samples. There appears to be a uniform bias across all five preservation methods against microorganisms with high G + C DNA. Overall, the liquid-based preservatives (DNAgard(™), RNAlater(®), and DESS) outperformed the card-based methods. No single liquid method clearly outperformed the others, leaving method choice to be based on experimental design, field facilities, shipping constraints, and allowable cost. © 2012 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.

  4. The analysis of uranium in environmental sample by mass spectrometer combined with isotopic dilution

    International Nuclear Information System (INIS)

    Fu Zhonghua; Jia Baoting; Han Jun

    2003-01-01

    Uranium in the environmental sample was analyzed by mass spectrometer combined with isotopic dilution. Before mass spectrometer analysis, samples were dissolved in a concentrated acidic solution containing HNO 3 , HF and HClO 4 and chemically processed to suit the analysis requirement. Analysis results indicated that the uranium content was 0.08 μg/g in river water, 0.1 μg/g in evergreen foliage, and 5-11 μg/g in surface soil respectively. (authors)

  5. Adsorptive stripping voltammetric determination of trace amounts of lead in environmental water samples with complicated matrix

    Directory of Open Access Journals (Sweden)

    Grabarczyk M.

    2013-04-01

    Full Text Available A sensitive, simple and fast adsorptive stripping voltammetric procedure for trace determination of lead in environmental water samples has been developed. The method is based on adsorptive accumulation of the Pb(II-cupferron complex onto a hanging mercury drop electrode, followed by the reduction of the adsorbed species by a voltammetric scan using differential pulse modulation. The interference from surface active substances was eliminated by adsorption of interferents onto an Amberlite XAD-16 resin. Optimumconditions for removing the surfactants by mixing the analysed sample with resin were evaluated. The accuracy of the method was tested by analyzing certified reference material (SPS-WW1 Waste Water.

  6. Sampling for Beryllium Surface Contamination using Wet, Dry and Alcohol Wipe Sampling

    Energy Technology Data Exchange (ETDEWEB)

    Kerr, Kent [Central Missouri State Univ., Warrensburg, MO (United States)

    2004-12-01

    This research project was conducted at the National Nuclear Security Administration's Kansas City Plant, operated by Honeywell Federal Manufacturing and Technologies, in conjunction with the Safety Sciences Department of Central Missouri State University, to compare relative removal efficiencies of three wipe sampling techniques currently used at Department of Energy facilities. Efficiencies of removal of beryllium contamination from typical painted surfaces were tested by wipe sampling with dry Whatman 42 filter paper, with water-moistened (Ghost Wipe) materials, and by methanol-moistened wipes. Test plates were prepared using 100 mm X 15 mm Pyrex Petri dishes with interior surfaces spray painted with a bond coat primer. To achieve uniform deposition over the test plate surface, 10 ml aliquots of solution containing 1 beryllium and 0.1 ml of metal working fluid were transferred to the test plates and subsequently evaporated. Metal working fluid was added to simulate the slight oiliness common on surfaces in metal working shops where fugitive oil mist accumulates over time. Sixteen test plates for each wipe method (dry, water, and methanol) were processed and sampled using a modification of wiping patterns recommended by OSHA Method 125G. Laboratory and statistical analysis showed that methanol-moistened wipe sampling removed significantly more (about twice as much) beryllium/oil-film surface contamination as water-moistened wipes (p< 0.001), which removed significantly more (about twice as much) residue as dry wipes (p <0.001). Evidence for beryllium sensitization via skin exposure argues in favor of wipe sampling with wetting agents that provide enhanced residue removal efficiency.

  7. Radioactive kryptonates in the analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.

    1986-01-01

    The term ''radioactive Kryptonates'' is used for substances into which atoms or ions of the radioactive nuclide 85 Kr are incorporated. The basis of the use of radioactive Kryptonates in analytical chemistry is that during a chemical reaction the crystalline lattice of the kryptonated carrier is destroyed, the carrier consumed, and the radioactive krypton released (radio-release method). Analysis can be made with a calibration curve or by comparison with a standard. Radio-release methods with the aid of radioactive Kryptonates as analytical reagents are very useful for the analysis of environmental samples, e.g. for the determination of air pollutants (ozone, sulphur dioxide, fluorine, hydrogen fluoride, mercury); and water pollutants (oxygen, dichromate, vanadium, hydrochloric acid, sulphur dioxide). (author)

  8. Gamma-spectrometry of extended sources for analysing environmental samples

    International Nuclear Information System (INIS)

    Jarosievitz, B.

    1996-01-01

    Measurements of the environmental activity concentration by gamma spectrometers require the determination of the full-energy-peak efficiency as a function of photon energy over the detector range. This can be done by experiments or by calculation. For simple cases, experiments are straightforward, but if the decay scheme is complex, cascade effects modify detection efficiency. Also, actual detection efficiency depends on the detection geometry. All these effects are treated as corrections or modifications of the simple value cases which are especially relevant when applied to large volume of environmental samples. In this thesis calculations are made, using the GEANT MC program, for realistic experimental situations that have been performed, and these calculations are validated. The calculational and experimental results have been compared, and if it proves to be satisfactory, the results can be relied on even for cases when no direct experimental observation is possible. The general problems of gamma spectroscopy and correction problems are discussed. The two main tools, the experimental setup and the simulation program are described. A careful checking of the simulation results and the consequences are presented. (R.P.)

  9. [DOE method for evaluating environmental and waste management samples: Revision 1, Addendum 1

    International Nuclear Information System (INIS)

    Goheen, S.C.

    1995-04-01

    The US Dapartment of Energy's (DOE's) environmental and waste management (EM) sampling and analysis activities require that large numbers of samples be analyzed for materials characterization, environmental surveillance, and site-remediation programs. The present document, DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), is a supplemental resource for analyzing many of these samples

  10. [DOE method for evaluating environmental and waste management samples: Revision 1, Addendum 1

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S.C.

    1995-04-01

    The US Dapartment of Energy`s (DOE`s) environmental and waste management (EM) sampling and analysis activities require that large numbers of samples be analyzed for materials characterization, environmental surveillance, and site-remediation programs. The present document, DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), is a supplemental resource for analyzing many of these samples.

  11. Conformity Assessment in Nuclear Material and Environmental Sample Analysis

    International Nuclear Information System (INIS)

    Aregbe, Y.; Jakopic, R.; Richter, S.; Venchiarutti, C.

    2015-01-01

    Safeguards conclusions are based to a large extent on comparison of measurement results between operator and safeguards laboratories. Measurement results must state traceability and uncertainties to be comparable. Recent workshops held at the IAEA and in the frame of the European Safeguards Research and Development Association (ESARDA), reviewed different approaches for Nuclear Material Balance Evaluation (MBE). Among those, the ''bottom-up'' approach requires assessment of operators and safeguards laboratories measurement systems and capabilities. Therefore, inter-laboratory comparisons (ILCs) with independent reference values provided for decades by JRC-IRMM, CEA/CETAMA and US DOE are instrumental to shed light on the current state of practice in measurements of nuclear material and environmental swipe samples. Participating laboratories are requested to report the measurement results with associated uncertainties, and have the possibility to benchmark those results against independent and traceable reference values. The measurement capability of both the IAEA Network of Analytical Laboratories (NWAL) and the nuclear operator's analytical services participating in ILCs can be assessed against the independent reference values as well as against internationally agreed quality goals, in compliance with ISO 13528:2005. The quality goals for nuclear material analysis are the relative combined standard uncertainties listed in the ITV2010. Concerning environmental swipe sample analysis, the IAEA defined measurement quality goals applied in conformity assessment. The paper reports examples from relevant inter-laboratory comparisons, looking at laboratory performance according to the purpose of the measurement and the possible use of the result in line with the IUPAC International Harmonized Protocol. Tendencies of laboratories to either overestimate and/or underestimate uncertainties are discussed using straightforward graphical tools to evaluate

  12. Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis

    Science.gov (United States)

    Kovač Viršek, Manca; Palatinus, Andreja; Koren, Špela; Peterlin, Monika; Horvat, Petra; Kržan, Andrej

    2016-01-01

    Microplastic pollution in the marine environment is a scientific topic that has received increasing attention over the last decade. The majority of scientific publications address microplastic pollution of the sea surface. The protocol below describes the methodology for sampling, sample preparation, separation and chemical identification of microplastic particles. A manta net fixed on an »A frame« attached to the side of the vessel was used for sampling. Microplastic particles caught in the cod end of the net were separated from samples by visual identification and use of stereomicroscopes. Particles were analyzed for their size using an image analysis program and for their chemical structure using ATR-FTIR and micro FTIR spectroscopy. The described protocol is in line with recommendations for microplastics monitoring published by the Marine Strategy Framework Directive (MSFD) Technical Subgroup on Marine Litter. This written protocol with video guide will support the work of researchers that deal with microplastics monitoring all over the world. PMID:28060297

  13. Middlesex Sampling Plant annual environmental report for calendar year 1991, Middlesex, New Jersey

    International Nuclear Information System (INIS)

    1992-09-01

    This document describes the environmental monitoring program at the-Middlesex Sampling Plant (MSP) and surrounding area, implementation of the program, and monitoring results for 1991. Environmental monitoring of MSP began in 1980 when Congress added the site to the US Department of Energy's (DOE) Formerly Utilized Sites Remedial Action Program (FUSRAP). FUSRAP is a DOE program to decontaminate or otherwise control sites where residual radioactive materials remain from the early years of the nation's atomic energy program or from commercial operations causing conditions that Congress has authorized DOE to remedy. The environmental monitoring program at MSP includes sampling networks for radon and thoron concentrations in air; external gamma radiation exposure; and radium-226, thorium-232, and total uranium concentrations in surface water, sediment,, and groundwater. Additionally, several nonradiological parameters are measured in groundwater, surface water, and sediment. Results of environmental monitoring during 1991 indicate that most concentrations were well below applicable guidelines. The potential radiation dose calculated for a hypothetical maximally exposed individual, based on a conservative but realistic exposure scenario, is 2.3 mrem (milliroentgen equivalent man) per year, which is less than an individual would receive while traveling in an airplane at 12,000 meters for five hours. During 1991, there were no nonroutine releases from the site; MSP was in compliance with applicable regulations for releases from the site. Site activities included environmental monitoring, site maintenance, onsite characterization for the MSP remedial investigation, and additional sediment sampling at the plant outfall to determine the source of the elevated levels of radium-226 and thorium-232

  14. Aspects of cleaning environmental materials for multi-element analysis, e.g. plant samples

    International Nuclear Information System (INIS)

    Markert, B.

    1992-01-01

    Cleaning of samples is often the first step in the entire procedure of sample preparation in environmental trace element research. The question must generally be raised of whether cleaning is meaningful before chemical investigations with plant material (e.g. for the determination of transfer factors in the soil/plant system) or not (e.g. for food chain analysis in the plant/animal system). The most varied cleaning procedures for plant samples are currently available ranging from dry and wet wiping of the leaf or needle surface up to the complete removal of the cuticule with the aid of chlorofom. There is at present no standardized cleaning procedure for plant samples so that it is frequently not possible to compare analytical data from different working groups studying the same plant species. (orig.)

  15. Detection of Chlamydophila psittaci from feral pigeons in environmental samples: problems with currently available techniques.

    Science.gov (United States)

    Geigenfeind, Ila; Haag-Wackernagel, Daniel

    2010-03-01

    Chlamydophila psittaci (Lillie, 1930) Everett et al., 1999, the pathogenic agent of human ornithosis, is widespread in feral pigeon populations and many cases of transmission from feral pigeons to humans have been reported. The aim of the present study was to detect C. psittaci in environmental samples to find out more about possible transmission routes and, therefore, to assess the zoonotic risk for humans. Fecal samples were collected from nest boxes in a feral pigeon loft. Additionally, samples were taken from the feather dust film covering the water surface of public fountains where pigeons regularly bathe. The samples were tested for the presence of chlamydial antigen using an antigen enzyme-linked immunosorbent assay to prove shedding of C. psittaci by feral pigeons. This test detects a genus specific lipopolysaccharide in the outer membrane of the chlamydial bacteria. Samples were tested using the IDEIA PCE Chlamydia Test kit (DakoCytomation) and positive results were verified with IDEIA Chlamydia Blocking Reagents (DakoCytomation). The IDEIA PCE Chlamydia Test yields a high proportion of positive results. However, when IDEIA Chlamydia Blocking was performed, most of the positive results turned out to be negative or could not be interpreted. We conclude that antigen-enzyme-linked immunosorbent assay tests are not suitable for detecting C. psittaci in environmental samples. Previous publications where no blocking test was used should be reconsidered critically. © 2010 ISZS, Blackwell Publishing and IOZ/CAS.

  16. Technical Note: New methodology for measuring viscosities in small volumes characteristic of environmental chamber particle samples

    Directory of Open Access Journals (Sweden)

    L. Renbaum-Wolff

    2013-01-01

    Full Text Available Herein, a method for the determination of viscosities of small sample volumes is introduced, with important implications for the viscosity determination of particle samples from environmental chambers (used to simulate atmospheric conditions. The amount of sample needed is < 1 μl, and the technique is capable of determining viscosities (η ranging between 10−3 and 103 Pascal seconds (Pa s in samples that cover a range of chemical properties and with real-time relative humidity and temperature control; hence, the technique should be well-suited for determining the viscosities, under atmospherically relevant conditions, of particles collected from environmental chambers. In this technique, supermicron particles are first deposited on an inert hydrophobic substrate. Then, insoluble beads (~1 μm in diameter are embedded in the particles. Next, a flow of gas is introduced over the particles, which generates a shear stress on the particle surfaces. The sample responds to this shear stress by generating internal circulations, which are quantified with an optical microscope by monitoring the movement of the beads. The rate of internal circulation is shown to be a function of particle viscosity but independent of the particle material for a wide range of organic and organic-water samples. A calibration curve is constructed from the experimental data that relates the rate of internal circulation to particle viscosity, and this calibration curve is successfully used to predict viscosities in multicomponent organic mixtures.

  17. Artificial radioactivity in the environmental samples as IAEA reference materials

    International Nuclear Information System (INIS)

    Salagean, M.; Pantelica, A.

    1998-01-01

    . Uncontaminated by nuclear activities: IAEA-327, Podsolic soil collected in 1990 from the Moscow region and considered uncontaminated by radionuclides of the Chernobyl accident or by other nuclear activities. The results obtained by our laboratory are in good agreement with the certified IAEA data. Generally, the concentration of the artificial radionuclides in the investigated samples is higher than that expected from the influence of global fallout in the intercomparison materials distributed before Chernobyl accident. Concerning the nature of these investigated IAEA reference materials, very high values for the concentration levels of cesium radionuclides especially in IAEA-373 (grass) and IAEA-375 (soil) samples collected in the vicinity of Chernobyl Power Station after the nuclear accident in 1986 were found. High levels of radioactivities for the artificial radionuclides were also determined in the samples collected in the neighbourhood of the nuclear installations, especially in marine sediment (IAEA-135). It is of interest to point out the high concentration of cesium radionuclides in IAEA-300 sediment collected in 1992 in the Baltic Sea in comparison with the IAEA-306 sediment collected also in the Baltic Sea in 1986. It seems to be an increase of the Baltic Sea artificial radioactivity by accumulation in time. Marine sediment constitutes an important component of marine ecosystem since it represents the final sink for any releases of wastes into the sea. These certified radioactive materials are very useful to all laboratories engaged in the radioactive pollution investigations on environmental samples. (authors)

  18. Geostatistical integration and uncertainty in pollutant concentration surface under preferential sampling

    Directory of Open Access Journals (Sweden)

    Laura Grisotto

    2016-04-01

    Full Text Available In this paper the focus is on environmental statistics, with the aim of estimating the concentration surface and related uncertainty of an air pollutant. We used air quality data recorded by a network of monitoring stations within a Bayesian framework to overcome difficulties in accounting for prediction uncertainty and to integrate information provided by deterministic models based on emissions meteorology and chemico-physical characteristics of the atmosphere. Several authors have proposed such integration, but all the proposed approaches rely on representativeness and completeness of existing air pollution monitoring networks. We considered the situation in which the spatial process of interest and the sampling locations are not independent. This is known in the literature as the preferential sampling problem, which if ignored in the analysis, can bias geostatistical inferences. We developed a Bayesian geostatistical model to account for preferential sampling with the main interest in statistical integration and uncertainty. We used PM10 data arising from the air quality network of the Environmental Protection Agency of Lombardy Region (Italy and numerical outputs from the deterministic model. We specified an inhomogeneous Poisson process for the sampling locations intensities and a shared spatial random component model for the dependence between the spatial location of monitors and the pollution surface. We found greater predicted standard deviation differences in areas not properly covered by the air quality network. In conclusion, in this context inferences on prediction uncertainty may be misleading when geostatistical modelling does not take into account preferential sampling.

  19. Capability of environmental sampling to detect undeclared cask openings

    International Nuclear Information System (INIS)

    Beckstead, L.W.; Efurd, D.W.; Hemberger, P.H.; Abhold, M.E.; Eccleston, G.W.

    1997-01-01

    The goal of this study is to determine the signatures that would allow monitors to detect diversion of nuclear fuel (by a diverter) from a storage area such as a geological repository. Due to the complexity of operations surrounding disposal of spent nuclear fuel in a geologic repository, there are several places that a diversion of fuel could take place. After the canister that contains the fuel rods is breached, the diverter would require a hot cell to process or repackage the fuel. A reference repository and possible diversion scenarios are discussed. When a canister is breached, or during reprocessing to extract nuclear weapons material (primarily Pu), several important isotopes or signatures including tritium, 85 Kr, and 129 I are released to the surrounding environment and have the potential for analysis. Estimates of release concentrations of the key signatures from the repository under a hypothetical diversion scenario are presented and discussed. Gas analysis data collected from above-ground storage casks at Idaho National Engineering and Environmental Laboratory (INEEL) Test Area North (TAN) are included and discussed in the report. In addition, LANL participated in gas sampling of one TAN cask, the Castor V/21, in July 1997. Results of xenon analysis from the cask gas sample are presented and discussed. The importance of global fallout and recent commercial reprocessing activities and their effects on repository monitoring are discussed. Monitoring and instrumental equipment for analysis of the key signature isotopes are discussed along with limits of detection. A key factor in determining if diversion activities are in progress at a repository is the timeliness of detection and analysis of the signatures. Once a clandestine operation is suspected, analytical data should be collected as quickly as possible to support any evidence of diversion

  20. Capability of environmental sampling to detect undeclared cask openings

    Energy Technology Data Exchange (ETDEWEB)

    Beckstead, L.W.; Efurd, D.W.; Hemberger, P.H.; Abhold, M.E.; Eccleston, G.W.

    1997-12-01

    The goal of this study is to determine the signatures that would allow monitors to detect diversion of nuclear fuel (by a diverter) from a storage area such as a geological repository. Due to the complexity of operations surrounding disposal of spent nuclear fuel in a geologic repository, there are several places that a diversion of fuel could take place. After the canister that contains the fuel rods is breached, the diverter would require a hot cell to process or repackage the fuel. A reference repository and possible diversion scenarios are discussed. When a canister is breached, or during reprocessing to extract nuclear weapons material (primarily Pu), several important isotopes or signatures including tritium, {sup 85}Kr, and {sup 129}I are released to the surrounding environment and have the potential for analysis. Estimates of release concentrations of the key signatures from the repository under a hypothetical diversion scenario are presented and discussed. Gas analysis data collected from above-ground storage casks at Idaho National Engineering and Environmental Laboratory (INEEL) Test Area North (TAN) are included and discussed in the report. In addition, LANL participated in gas sampling of one TAN cask, the Castor V/21, in July 1997. Results of xenon analysis from the cask gas sample are presented and discussed. The importance of global fallout and recent commercial reprocessing activities and their effects on repository monitoring are discussed. Monitoring and instrumental equipment for analysis of the key signature isotopes are discussed along with limits of detection. A key factor in determining if diversion activities are in progress at a repository is the timeliness of detection and analysis of the signatures. Once a clandestine operation is suspected, analytical data should be collected as quickly as possible to support any evidence of diversion.

  1. Voltammetric technique, a panacea for analytical examination of environmental samples

    International Nuclear Information System (INIS)

    Zahir, E.; Mohiuddin, S.; Naqvi, I.I.

    2012-01-01

    Voltammetric methods for trace metal analysis in environmental samples of marine origin like mangrove, sediments and shrimps are generally recommended. Three different electro-analytical techniques i.e. polarography, anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (ADSV) have been used. Cd/sub 2/+, Pb/sub 2/+, Cu/sub 2/+ and Mn/sub 2/+ were determined through ASV, Cr/sub 6/+ was analyzed by ADSV and Fe/sub 2/+, Zn/sub 2/+, Ni/sub 2/+ and Co/sub 2/+ were determined through polarography. Out of which pairs of Fe/sub 2/+Zn/sub 2/+ and Ni/sub 2/+Co/sub 2/+ were determined in two separate runs while Cd/sub 2/+, Pb/sub 2/+, Cu/sub 2/+ were analyzed in single run of ASV. Sensitivity and speciation capabilities of voltammetric methods have been employed. Analysis conditions were optimized that includes selection of supporting electrolyte, pH, working electrodes, sweep rate etc. Stripping voltammetry was adopted for analysis at ultra trace levels. Statistical parameters for analytical method development like selectivity factor, interference, repeatability (0.0065-0.130 macro g/g), reproducibility (0.08125-1.625 macro g/g), detection limits (0.032-5.06 macro g/g), limits of quantification (0.081-12.652 macro g/g), sensitivities (5.636-2.15 nA mL macro g-1) etc. were also determined. The percentage recoveries were found in between 95-105% using certified reference materials. Real samples of complex marine environment from Karachi coastline were also analyzed. The standard addition method was employed where any matrix effect was evidenced. (author)

  2. Surface Sampling Collection and Culture Methods for Escherichia coli in Household Environments with High Fecal Contamination.

    Science.gov (United States)

    Exum, Natalie G; Kosek, Margaret N; Davis, Meghan F; Schwab, Kellogg J

    2017-08-22

    Empiric quantification of environmental fecal contamination is an important step toward understanding the impact that water, sanitation, and hygiene interventions have on reducing enteric infections. There is a need to standardize the methods used for surface sampling in field studies that examine fecal contamination in low-income settings. The dry cloth method presented in this manuscript improves upon the more commonly used swabbing technique that has been shown in the literature to have a low sampling efficiency. The recovery efficiency of a dry electrostatic cloth sampling method was evaluated using Escherichia coli and then applied to household surfaces in Iquitos, Peru, where there is high fecal contamination and enteric infection. Side-by-side measurements were taken from various floor locations within a household at the same time over a three-month period to compare for consistency of quantification of E. coli bacteria. The dry cloth sampling method in the laboratory setting showed 105% (95% Confidence Interval: 98%, 113%) E. coli recovery efficiency off of the cloths. The field application demonstrated strong agreement of side-by-side results (Pearson correlation coefficient for dirt surfaces was 0.83 ( p samples (Pearson (0.53, p method can be utilized in households with high bacterial loads using either continuous (quantitative) or categorical (semi-quantitative) data. The standardization of this low-cost, dry electrostatic cloth sampling method can be used to measure differences between households in intervention and non-intervention arms of randomized trials.

  3. Methods to maximise recovery of environmental DNA from water samples.

    Directory of Open Access Journals (Sweden)

    Rheyda Hinlo

    Full Text Available The environmental DNA (eDNA method is a detection technique that is rapidly gaining credibility as a sensitive tool useful in the surveillance and monitoring of invasive and threatened species. Because eDNA analysis often deals with small quantities of short and degraded DNA fragments, methods that maximize eDNA recovery are required to increase detectability. In this study, we performed experiments at different stages of the eDNA analysis to show which combinations of methods give the best recovery rate for eDNA. Using Oriental weatherloach (Misgurnus anguillicaudatus as a study species, we show that various combinations of DNA capture, preservation and extraction methods can significantly affect DNA yield. Filtration using cellulose nitrate filter paper preserved in ethanol or stored in a -20°C freezer and extracted with the Qiagen DNeasy kit outperformed other combinations in terms of cost and efficiency of DNA recovery. Our results support the recommendation to filter water samples within 24hours but if this is not possible, our results suggest that refrigeration may be a better option than freezing for short-term storage (i.e., 3-5 days. This information is useful in designing eDNA detection of low-density invasive or threatened species, where small variations in DNA recovery can signify the difference between detection success or failure.

  4. Metagenomic covariation along densely sampled environmental gradients in the Red Sea

    Science.gov (United States)

    Thompson, Luke R; Williams, Gareth J; Haroon, Mohamed F; Shibl, Ahmed; Larsen, Peter; Shorenstein, Joshua; Knight, Rob; Stingl, Ulrich

    2017-01-01

    Oceanic microbial diversity covaries with physicochemical parameters. Temperature, for example, explains approximately half of global variation in surface taxonomic abundance. It is unknown, however, whether covariation patterns hold over narrower parameter gradients and spatial scales, and extending to mesopelagic depths. We collected and sequenced 45 epipelagic and mesopelagic microbial metagenomes on a meridional transect through the eastern Red Sea. We asked which environmental parameters explain the most variation in relative abundances of taxonomic groups, gene ortholog groups, and pathways—at a spatial scale of water mass with different physicochemical properties. Temperature explained the most variation in each metric, followed by nitrate, chlorophyll, phosphate, and salinity. That nitrate explained more variation than phosphate suggested nitrogen limitation, consistent with low surface N:P ratios. Covariation of gene ortholog groups with environmental parameters revealed patterns of functional adaptation to the challenging Red Sea environment: high irradiance, temperature, salinity, and low nutrients. Nutrient-acquisition gene ortholog groups were anti-correlated with concentrations of their respective nutrient species, recapturing trends previously observed across much larger distances and environmental gradients. This dataset of metagenomic covariation along densely sampled environmental gradients includes online data exploration supplements, serving as a community resource for marine microbial ecology. PMID:27420030

  5. Environmental performance assessment of a company of aluminum surface treatment

    Directory of Open Access Journals (Sweden)

    Susan Catieri Ramalho

    2013-08-01

    Full Text Available The purpose of this article was to evaluate the environmental performance of a medium-sized company that provides services for surface treatment of aluminum. The treatment is known as anodizing. The research method was qualitative numerical modeling. The environmental performance of the company was organized into five constructs: atmosphere, wastewater, energy and natural resources, solid waste, and legislation and management. Nineteen indicators were chosen to explain the five constructs. Ten employees of the company prioritized the constructs and evaluated the situation of the indicators by means of a scale of assessment. By means of a mathematical model, the general performance of the environmental operation was calculated at 74.5% of the maximum possible. The indicators that most contributed to the performance not to reach 100% were consumption of electricity and water consumption. The construct of worse performance was natural and energy resources. These are the priorities for future environmental improvement actions that the company may promote.

  6. Establishment of a clean laboratory for ultra trace analysis of nuclear materials in safeguards environmental samples

    International Nuclear Information System (INIS)

    Hanzawa, Yukiko; Magara, Masaaki; Watanabe, Kazuo

    2003-01-01

    The Japan Atomic Energy Research Institute has established a cleanroom facility with cleanliness of ISO Class 5: the Clean Laboratory for Environmental Analysis and Research (CLEAR). It was designed to be used for the analysis of nuclear materials in environmental samples mainly for the safeguards, in addition to the Comprehensive Nuclear-Test-Ban Treaty verification and research on environmental sciences. The CLEAR facility was designed to meet conflicting requirements of a cleanroom and for handling of nuclear materials according to Japanese regulations, i.e., to avoid contamination from outside and to contain nuclear materials inside the facility. This facility has been intended to be used for wet chemical treatment, instrumental analysis and particle handling. A fume-hood to provide a clean work surface for handling of nuclear materials was specially designed. Much attention was paid to the selection of construction materials for use to corrosive acids. The performance of the cleanroom and analytical background in the laboratory are discussed. This facility has satisfactory specification required for joining the International Atomic Energy Agency Network of Analytical Laboratories. It can be concluded that the CLEAR facility enables analysis of ultra trace amounts of nuclear materials at sub-pictogram level in environmental samples. (author)

  7. Dielectrophoretic sample preparation for environmental monitoring of microorganisms: Soil particle removal.

    Science.gov (United States)

    Fatoyinbo, Henry O; McDonnell, Martin C; Hughes, Michael P

    2014-07-01

    Detection of pathogens from environmental samples is often hampered by sensors interacting with environmental particles such as soot, pollen, or environmental dust such as soil or clay. These particles may be of similar size to the target bacterium, preventing removal by filtration, but may non-specifically bind to sensor surfaces, fouling them and causing artefactual results. In this paper, we report the selective manipulation of soil particles using an AC electrokinetic microfluidic system. Four heterogeneous soil samples (smectic clay, kaolinitic clay, peaty loam, and sandy loam) were characterised using dielectrophoresis to identify the electrical difference to a target organism. A flow-cell device was then constructed to evaluate dielectrophoretic separation of bacteria and clay in a continous flow through mode. The average separation efficiency of the system across all soil types was found to be 68.7% with a maximal separation efficiency for kaolinitic clay at 87.6%. This represents the first attempt to separate soil particles from bacteria using dielectrophoresis and indicate that the technique shows significant promise; with appropriate system optimisation, we believe that this preliminary study represents an opportunity to develop a simple yet highly effective sample processing system.

  8. Middlesex Sampling Plant environmental report for calendar year 1992, 239 Mountain Avenue, Middlesex, New Jersey

    International Nuclear Information System (INIS)

    1993-05-01

    This report describes the environmental surveillance program at the Middlesex Sampling Plant (MSP) and provides the results for 1992. The site, in the Borough of Middlesex, New Jersey, is a fenced area and includes four buildings and two storage piles that contain 50,800 m 3 of radioactive and mixed hazardous waste. More than 70 percent of the MSP site is paved with asphalt. The MSP facility was established in 1943 by the Manhattan Engineer District (MED) to sample, store, and/or ship uranium, thorium, and beryllium ores. In 1955 the Atomic Energy Commission (AEC), successor to MED, terminated the operation and later used the site for storage and limited sampling of thorium residues. In 1967 AEC activities ceased, onsite structures were decontaminated, and the site was certified for unrestricted use under criteria applicable at that time. In 1980 the US Department of Energy (DOE) initiated a multiphase remedial action project to clean up several vicinity properties onto which contamination from the plant had migrated. Material from these properties was consolidated into the storage piles onsite. Environmental surveillance of MSP began in 1980 when Congress added the site to DOE's Formerly Utilized Sites Remedial Action Program. The environmental surveillance program at MSP includes sampling networks for radon and thoron in air; external gamma radiation exposure; and radium-226, radium-228, thorium-230, thorium-232, and total uranium in surface water, sediment, and groundwater. Additionally, chemical analyses are performed to detect metals and organic compounds in surface water and groundwater and metals in sediments. This program assists in fulfilling th DOE policy of measuring and monitoring effluents from DOE activities and calculating hypothetical doses

  9. New Lipids From Cultured Archaea and Environmental Samples

    Science.gov (United States)

    Summons, R. E.; Meyer-Dombard, D. R.; Bradley, A. S.; Hebting, Y.; Jahnke, L. L.; Embaye, T.; Orphan, V. J.

    2006-12-01

    The intact polar lipids of Archaea comprise cores with isoprenoid hydrocarbon chains with 20, 25 or 40 carbon atoms linked through ether bonds to glycerol. These cores can take the form of diethers or membrane- spanning tetraethers. Together with their wide array of polar head groups, these compounds are structurally diverse and potentially very useful as taxonomic markers for making assessments of microbial diversity independently of genomic approaches. Furthermore, the recalcitrant hydrocarbon chains of these lipids are the only really effective means to identify the presence of Archaea in ancient sedimentary environments. The advent of new LC-MS methods has enabled ready identification and quantification of intact polar lipids in cultures and environmental samples based on comparisons with appropriate standard compounds [1, 2]. However, these LC-MS analyses of intact lipids have also revealed the presence of additional compounds and it is likely that many of these represent chemical structures that are new to science. Elucidating these structures is a major analytical challenge because, generally, only minute amounts of material available for chemical characterization. In order to study these potentially new structures, one layer of information can be obtained by chemical degradation to remove and identify the polar head groups [2]. Cleavage of the ether bonds releases the hydrocarbon chains for their further characterization. One class of core lipids, the 3-hydroxyarchaeols, escaped detection for many years because strong acid treatments in the analysis protocols had destroyed hydroxyl-containing isoprenoid chains. We have now re-examined the lipids of a thermophilic methanogen, M. thermolithotrophicus, using mild procedures and avoiding strong acids. As well as the known compounds archaeol, sn-2-hydroxyarchaeol and sn-3-hydroxyarchaeol, we encountered dihydroxyarchaeol. Moreover, the hydroxylated archaeols were found to exist as a very complex mixture of

  10. Genomic Sequencing of Single Microbial Cells from Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Ishoey, Thomas; Woyke, Tanja; Stepanauskas, Ramunas; Novotny, Mark; Lasken, Roger S.

    2008-02-01

    Recently developed techniques allow genomic DNA sequencing from single microbial cells [Lasken RS: Single-cell genomic sequencing using multiple displacement amplification, Curr Opin Microbiol 2007, 10:510-516]. Here, we focus on research strategies for putting these methods into practice in the laboratory setting. An immediate consequence of single-cell sequencing is that it provides an alternative to culturing organisms as a prerequisite for genomic sequencing. The microgram amounts of DNA required as template are amplified from a single bacterium by a method called multiple displacement amplification (MDA) avoiding the need to grow cells. The ability to sequence DNA from individual cells will likely have an immense impact on microbiology considering the vast numbers of novel organisms, which have been inaccessible unless culture-independent methods could be used. However, special approaches have been necessary to work with amplified DNA. MDA may not recover the entire genome from the single copy present in most bacteria. Also, some sequence rearrangements can occur during the DNA amplification reaction. Over the past two years many research groups have begun to use MDA, and some practical approaches to single-cell sequencing have been developed. We review the consensus that is emerging on optimum methods, reliability of amplified template, and the proper interpretation of 'composite' genomes which result from the necessity of combining data from several single-cell MDA reactions in order to complete the assembly. Preferred laboratory methods are considered on the basis of experience at several large sequencing centers where >70% of genomes are now often recovered from single cells. Methods are reviewed for preparation of bacterial fractions from environmental samples, single-cell isolation, DNA amplification by MDA, and DNA sequencing.

  11. Development of analytical techniques for water and environmental samples (2)

    Energy Technology Data Exchange (ETDEWEB)

    Eum, Chul Hun; Jeon, Chi Wan; Jung, Kang Sup; Song, Kyung Sun; Kim, Sang Yeon [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    The purpose of this study is to develop new analytical methods with good detection limit for toxic inorganic and organic compounds. The analyses of CN, organic acids, particulate materials in environmental samples have been done using several methods such as Ion Chromatography, SPE, SPME, GC/MS, GC/FID, SPLITT (split-flow thin cell fractionation) during the second year of this project. Advantage and disadvantage of several distillation method (by KS, JIS, EPA) for CN analysis in wastewater were investigated. As the results, we proposed new distillation apparatus for CN analysis, which was proved to be simpler, faster and to get better recovery than conventional apparatus. And ion chromatograph/pulsed amperometric detector (IC/PAD) system instead of colorimetry for CN detection was setup to solve matrix interference. And SPE(solid phase extraction) and SPME (solid phase micro extraction) as liquid-solid extraction technique were applied to the analysis of phenols in wastewater. Optimum experimental conditions and factors influencing analytical results were determined. From these results, It could be concluded that C{sub 18} cartridge and polystyrene-divinylbenzene disk in SPE method, polyacrylate fiber in SPME were proper solid phase adsorbent for phenol. Optimum conditions to analyze phenol derivatives simultaneously were established. Also, Continuous SPLITT (Split-flow thin cell) Fractionation (CSF) is a new preparative separation technique that is useful for fractionation of particulate and macromolecular materials. CSF is carried out in a thin ribbon-like channel equipped with two splitters at both inlet and outlet of the channel. In this work, we set up a new CSF system, and tested using polystyrene latex standard particles. And then we fractionated particles contained in air and underground water based on their sedimentation coefficients using CSF. (author). 27 refs., 13 tabs., 31 figs.

  12. A method to combine non-probability sample data with probability sample data in estimating spatial means of environmental variables

    NARCIS (Netherlands)

    Brus, D.J.; Gruijter, de J.J.

    2003-01-01

    In estimating spatial means of environmental variables of a region from data collected by convenience or purposive sampling, validity of the results can be ensured by collecting additional data through probability sampling. The precision of the pi estimator that uses the probability sample can be

  13. Transgenic zebrafish reveal tissue-specific differences in estrogen signaling in response to environmental water samples.

    Science.gov (United States)

    Gorelick, Daniel A; Iwanowicz, Luke R; Hung, Alice L; Blazer, Vicki S; Halpern, Marnie E

    2014-04-01

    Environmental endocrine disruptors (EEDs) are exogenous chemicals that mimic endogenous hormones such as estrogens. Previous studies using a zebrafish transgenic reporter demonstrated that the EEDs bisphenol A and genistein preferentially activate estrogen receptors (ERs) in the larval heart compared with the liver. However, it was not known whether the transgenic zebrafish reporter was sensitive enough to detect estrogens from environmental samples, whether environmental estrogens would exhibit tissue-specific effects similar to those of BPA and genistein, or why some compounds preferentially target receptors in the heart. We tested surface water samples using a transgenic zebrafish reporter with tandem estrogen response elements driving green fluorescent protein expression (5xERE:GFP). Reporter activation was colocalized with tissue-specific expression of ER genes by RNA in situ hybridization. We observed selective patterns of ER activation in transgenic fish exposed to river water samples from the Mid-Atlantic United States, with several samples preferentially activating receptors in embryonic and larval heart valves. We discovered that tissue specificity in ER activation was due to differences in the expression of ER subtypes. ERα was expressed in developing heart valves but not in the liver, whereas ERβ2 had the opposite profile. Accordingly, subtype-specific ER agonists activated the reporter in either the heart valves or the liver. The use of 5xERE:GFP transgenic zebrafish revealed an unexpected tissue-specific difference in the response to environmentally relevant estrogenic compounds. Exposure to estrogenic EEDs in utero was associated with adverse health effects, with the potentially unanticipated consequence of targeting developing heart valves.

  14. Three-phase double-arc plasma for spectrochemical analysis of environmental samples.

    Science.gov (United States)

    Mohamed, M M; Ghatass, Z F; Shalaby, E A; Kotb, M M; El-Raey, M

    2000-12-01

    A new instrument, which uses a three-phase current to support a double-arc argon plasma torch for evaporation, atomization and excitation of solid or powder samples, is described. The sampling arc is ignited between the first and second electrode while the excitation arc is ignited between the second and third electrode. Aerosol generated from the sample (first electrode) is swept by argon gas, through a hole in the second electrode (carbon tubing electrode), into the excitation plasma. A tangential stream of argon gas is introduced through an inlet orifice as a coolant gas for the second electrode. This gas stream forces the excitation arc discharge to rotate reproducibly around the electrode surface. Discharge rotation increases the stability of the excitation plasma. Spectroscopic measurements are made directly in the current-carrying region of the excitation arc. An evaluation of each parameter influencing the device performance was performed. Analytical calibration curves were obtained for Fe, Al, K, and Pb. Finally, the present technique was applied for the analysis of environmental samples. The present method appears to have significant, low cost analytical utility for environmental measurements.

  15. Environmentally Friendly Cleaners for Removing Tar from Metal Surfaces

    Science.gov (United States)

    2009-04-01

    treatment plants that handle phosphate type solu- tions. The terms used by commercial vendors such as environmentally friendly, all natural, green, and...solvents used in relation to diesel fuel, and the procedure can also rank solvents quantitatively. Sacco (2004) has studied the blending of two plant ...other bituminous materials from industrial equipment surfaces. The composition is a mixture of a carrier monocyclic monoterpene and a nonionic

  16. Comparative evaluation of the US Environmental Protection Agency's and the Oak Ridge Institute for Science and Education's environmental survey and site assessment program field sampling procedures

    International Nuclear Information System (INIS)

    Vitkus, T.J.; Bright, T.L.; Roberts, S.A.

    1997-10-01

    At the request of the U.S. Nuclear Regulatory Commission's (NRC's) Headquarters Office, the Environmental Survey and Site Assessment Program (ESSAP) of the Oak Ridge Institute for Science and Education (ORISE) compared the documented procedures that the U.S. Environmental Protection Agency (EPA) and ESSAP use for collecting environmental samples. The project objectives were to review both organizations' procedures applicable to collecting various sample matrices, compare the procedures for similarities and differences, and then to evaluate the reason for any identified procedural differences and their potential impact on ESSAP's sample data quality. The procedures reviewed included those for sampling surface and subsurface soil, surface and groundwater, vegetation, air, and removable surface contamination. ESSAP obtained copies of relevant EPA documents and reviewed and prepared a tabulated summary of each applicable procedure. The methods for collecting and handling each type of sample were evaluated for differences, and where these were identified, the significance and effect of the differences on analytical quality were determined. The results of the comparison showed that, overall, the procedures and methods that EPA and ESSAP use for sample collection are very similar. The number of minor differences noted were the result of restrictions or procedures necessary to ensure sample integrity and prevent the introduction of interfering compounds when samples are to be analyzed for chemical parameters. For most radio nuclide analyses, these additional procedures are not necessary. Another item noted was EPA's inclusion of steps that reduce the potential for sample cross-contamination by preparing (dressing) a location prior to collecting a sample or removing a portion of a sample prior to containerization

  17. Metagenomic covariation along densely sampled environmental gradients in the Red Sea

    KAUST Repository

    Thompson, Luke R

    2016-07-15

    Oceanic microbial diversity covaries with physicochemical parameters. Temperature, for example, explains approximately half of global variation in surface taxonomic abundance. It is unknown, however, whether covariation patterns hold over narrower parameter gradients and spatial scales, and extending to mesopelagic depths. We collected and sequenced 45 epipelagic and mesopelagic microbial metagenomes on a meridional transect through the eastern Red Sea. We asked which environmental parameters explain the most variation in relative abundances of taxonomic groups, gene ortholog groups, and pathways—at a spatial scale of <2000 km, along narrow but well-defined latitudinal and depth-dependent gradients. We also asked how microbes are adapted to gradients and extremes in irradiance, temperature, salinity, and nutrients, examining the responses of individual gene ortholog groups to these parameters. Functional and taxonomic metrics were equally well explained (75–79%) by environmental parameters. However, only functional and not taxonomic covariation patterns were conserved when comparing with an intruding water mass with different physicochemical properties. Temperature explained the most variation in each metric, followed by nitrate, chlorophyll, phosphate, and salinity. That nitrate explained more variation than phosphate suggested nitrogen limitation, consistent with low surface N:P ratios. Covariation of gene ortholog groups with environmental parameters revealed patterns of functional adaptation to the challenging Red Sea environment: high irradiance, temperature, salinity, and low nutrients. Nutrient-acquisition gene ortholog groups were anti-correlated with concentrations of their respective nutrient species, recapturing trends previously observed across much larger distances and environmental gradients. This dataset of metagenomic covariation along densely sampled environmental gradients includes online data exploration supplements, serving as a community

  18. Evaluation of polyethersulfone performance for the microextraction of polar chlorinated herbicides from environmental water samples.

    Science.gov (United States)

    Prieto, Ailette; Rodil, Rosario; Quintana, José Benito; Cela, Rafael; Möder, Monika; Rodríguez, Isaac

    2014-05-01

    In this work, the suitability of bulk polyethersulfone (PES) for sorptive microextraction of eight polar, chlorinated phenoxy acids and dicamba from environmental water samples is assessed and the analytical features of the optimized method are compared to those reported for other microextraction techniques. Under optimized conditions, extractions were performed with samples (18 mL) adjusted at pH 2 and containing a 30% (w/v) of sodium chloride, using a tubular PES sorbent (1 cm length × 0.7 mm o.d., sorbent volume 8 µL). Equilibrium conditions were achieved after 3h of direct sampling, with absolute extraction efficiencies ranging from 39 to 66%, depending on the compound. Analytes were recovered soaking the polymer with 0.1 mL of ethyl acetate, derivatized and determined by gas chromatography-mass spectrometry (GC-MS). Achieved quantification limits (LOQs) varied between 0.005 and 0.073 ng mL(-1). After normalization with the internal surrogate (IS), the efficiency of the extraction was only moderately affected by the particular characteristics of different water samples (surface and sewage water); thus, pseudo-external calibration, using spiked ultrapure water solutions, can be used as quantification technique. The reduced cost of the PES polymer allowed considering it as a disposable sorbent, avoiding variations in the performance of the extraction due to cross-contamination problems and/or surface modification with usage. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Measuring environmental change in forest ecosystems by repeated soil sampling: a North American perspective

    Science.gov (United States)

    Lawrence, Gregory B.; Fernandez, Ivan J.; Richter, Daniel D.; Ross, Donald S.; Hazlett, Paul W.; Bailey, Scott W.; Oiumet, Rock; Warby, Richard A.F.; Johnson, Arthur H.; Lin, Henry; Kaste, James M.; Lapenis, Andrew G.; Sullivan, Timothy J.

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest ecosystems through repeated measurements are largely nascent and uncoordinated. In eastern North America, repeated soil sampling has begun to provide valuable information on environmental problems such as air pollution. This review synthesizes the current state of the science to further the development and use of soil resampling as an integral method for recording and understanding environmental change in forested settings. The origins of soil resampling reach back to the 19th century in England and Russia. The concepts and methodologies involved in forest soil resampling are reviewed and evaluated through a discussion of how temporal and spatial variability can be addressed with a variety of sampling approaches. Key resampling studies demonstrate the type of results that can be obtained through differing approaches. Ongoing, large-scale issues such as recovery from acidification, long-term N deposition, C sequestration, effects of climate change, impacts from invasive species, and the increasing intensification of soil management all warrant the use of soil resampling as an essential tool for environmental monitoring and assessment. Furthermore, with better awareness of the value of soil resampling, studies can be designed with a long-term perspective so that information can be efficiently obtained well into the future to address problems that have not yet surfaced.

  20. chemical and microbiological assessment of surface water samples

    African Journals Online (AJOL)

    PROF EKWUEME

    concentrations and bacteriological content. Evaluation of the results ... and Aninri local government areas of Enugu state. Surface water ... surface water bodies are prone to impacts from ... Coal Measures (Akamigbo, 1987). The geologic map ...

  1. Assessment of the Capability of the NGDS Prototype to Replace the JBAIDS for Environmental Sample Analysis

    Science.gov (United States)

    2016-11-01

    Diagnostic System (JBAIDS) for environmental sample analysis. JUPITR ATD and USAF members analyzed environmental samples using the FilmArray...requires 60+ min for sample preparation, whereas the FilmArray system (right) uses highly multiplexed assay pouches that require ᝺ min for sample...supported the evaluation of the BDCoE by analyzing spiked DFU samples using the Joint Biological Agent Identification and Diagnostic System (JBAIDS) and the

  2. Development of analytical methods for the separation of plutonium, americium, curium and neptunium from environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Salminen, S.

    2009-07-01

    In this work, separation methods have been developed for the analysis of anthropogenic transuranium elements plutonium, americium, curium and neptunium from environmental samples contaminated by global nuclear weapons testing and the Chernobyl accident. The analytical methods utilized in this study are based on extraction chromatography. Highly varying atmospheric plutonium isotope concentrations and activity ratios were found at both Kurchatov (Kazakhstan), near the former Semipalatinsk test site, and Sodankylae (Finland). The origin of plutonium is almost impossible to identify at Kurchatov, since hundreds of nuclear tests were performed at the Semipalatinsk test site. In Sodankylae, plutonium in the surface air originated from nuclear weapons testing, conducted mostly by USSR and USA before the sampling year 1963. The variation in americium, curium and neptunium concentrations was great as well in peat samples collected in southern and central Finland in 1986 immediately after the Chernobyl accident. The main source of transuranium contamination in peats was from global nuclear test fallout, although there are wide regional differences in the fraction of Chernobyl-originated activity (of the total activity) for americium, curium and neptunium. The separation methods developed in this study yielded good chemical recovery for the elements investigated and adequately pure fractions for radiometric activity determination. The extraction chromatographic methods were faster compared to older methods based on ion exchange chromatography. In addition, extraction chromatography is a more environmentally friendly separation method than ion exchange, because less acidic waste solutions are produced during the analytical procedures. (orig.)

  3. Middlesex Sampling Plant environmental report for calendar year 1989, Middlesex, New Jersey

    International Nuclear Information System (INIS)

    1990-05-01

    The environmental monitoring program, which began in 1980, was continued in 1989 at the former Middlesex Sampling Plant (MSP) site, located in the Borough of Middlesex, New Jersey. The MSP site is part of the Formerly Utilized Sites Remedial Action Program (FUSRAP), a Department of Energy (DOE) program to decontaminate or otherwise control sites where residual radioactive materials remain either from the early years of the nation's atomic energy program or from commercial operations causing conditions that Congress has authorized DOE to remedy. The monitoring program at MSP measures radon concentrations in air; external gamma radiation levels; and uranium and radium concentrations in surface water, groundwater, and sediment. Additionally, several nonradiological parameters are measured in groundwater samples. To verify that the site is in compliance with the DOE radiation protection standard (100 mrem/yr) and to assess its potential effect on public health, the radiation dose was calculated for a hypothetical maximally exposed individual. This report presents the findings of the environmental monitoring program conducted in the area of the Middlesex Sampling Plant (MSP) site during calendar year 1989. 17 refs., 16 figs., 16 tabs

  4. Middlesex Sampling Plant environmental report for calendar year 1989, Middlesex, New Jersey

    Energy Technology Data Exchange (ETDEWEB)

    1990-05-01

    The environmental monitoring program, which began in 1980, was continued in 1989 at the former Middlesex Sampling Plant (MSP) site, located in the Borough of Middlesex, New Jersey. The MSP site is part of the Formerly Utilized Sites Remedial Action Program (FUSRAP), a Department of Energy (DOE) program to decontaminate or otherwise control sites where residual radioactive materials remain either from the early years of the nation's atomic energy program or from commercial operations causing conditions that Congress has authorized DOE to remedy. The monitoring program at MSP measures radon concentrations in air; external gamma radiation levels; and uranium and radium concentrations in surface water, groundwater, and sediment. Additionally, several nonradiological parameters are measured in groundwater samples. To verify that the site is in compliance with the DOE radiation protection standard (100 mrem/yr) and to assess its potential effect on public health, the radiation dose was calculated for a hypothetical maximally exposed individual. This report presents the findings of the environmental monitoring program conducted in the area of the Middlesex Sampling Plant (MSP) site during calendar year 1989. 17 refs., 16 figs., 16 tabs.

  5. False negative rate and other performance measures of a sponge-wipe surface sampling method for low contaminant concentrations.

    Energy Technology Data Exchange (ETDEWEB)

    Einfeld, Wayne; Krauter, Paula A.; Boucher, Raymond M.; Tezak, Mathew; Amidan, Brett G. (Pacific Northwest National Laboratory, Richland, WA); Piepel, Greg F. (Pacific Northwest National Laboratory, Richland, WA)

    2011-05-01

    Recovery of spores from environmental surfaces is known to vary due to sampling methodology, techniques, spore size and characteristics, surface materials, and environmental conditions. A series of tests were performed to evaluate a new, validated sponge-wipe method. Specific factors evaluated were the effects of contaminant concentrations and surface materials on recovery efficiency (RE), false negative rate (FNR), limit of detection (LOD) - and the uncertainties of these quantities. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show a roughly linear dependence of surface roughness on RE, where the smoothest surfaces have the highest mean RE values. REs were not influenced by the low spore concentrations tested (3 x 10{sup -3} to 1.86 CFU/cm{sup 2}). The FNR data were consistent with RE data, showing a trend of smoother surfaces resulting in higher REs and lower FNRs. Stainless steel generally had the lowest mean FNR (0.123) and plastic had the highest mean FNR (0.479). The LOD{sub 90} varied with surface material, from 0.015 CFU/cm{sup 2} on stainless steel up to 0.039 on plastic. Selecting sampling locations on the basis of surface roughness and using roughness to interpret spore recovery data can improve sampling. Further, FNR values, calculated as a function of concentration and surface material, can be used pre-sampling to calculate the numbers of samples for statistical sampling plans with desired performance, and post-sampling to calculate the confidence in characterization and clearance decisions.

  6. BAYESIAN ENTROPY FOR SPATIAL SAMPLING DESIGN OF ENVIRONMENTAL DATA

    Science.gov (United States)

    Particulate Matter (PM) has been linked to widespread public health effects, including a range of serious respiratory and cardiovascular problems, and to reduced visibility in may parts of the United States, see the Environmental Protection Agency (EPA) report (2004) and relevant...

  7. a study of predictors of environmental behaviour using us samples

    African Journals Online (AJOL)

    ressed in curriculum development and instructional practice. The ultimate goal of ... lem solving behaviour may not be given due consid- eration because ... ion strategies. Respondents were assessed regard- ing their perceived ability to influence the sol- ution of environmental problems/issues either as an individual or ...

  8. Analysis of environmental samples by roentgen fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Hroncova, E.; Ladomersky, J.

    2004-01-01

    We can use it to analyse nearly all elements of solid and liquid samples. The possibility of analysing solid samples in compact shape, in powder or either under shape of fine layers shortens appreciably the total time of analysis, that is in addition to its no destructiveness, the main reason of as a XRF favourite method. (authors)

  9. Sampling procedure, receipt and conservation of water samples to determine environmental radioactivity

    International Nuclear Information System (INIS)

    Herranz, M.; Navarro, E.; Payeras, J.

    2009-01-01

    The present document informs about essential goals, processes and contents that the subgroups Sampling and Samples Preparation and Conservation believe they should be part of the procedure to obtain a correct sampling, receipt, conservation and preparation of samples of continental, marine and waste water before qualifying its radioactive content.

  10. Determination of uranium in industrial and environmental samples. Vol. 4

    Energy Technology Data Exchange (ETDEWEB)

    El-Sweify, F H; Shehata, M K; Metwally, E M; El-Shazly, E A.A.; El-Naggar, H A [Nuclear Chemistry Department, Hot Laborities Center, Atomic Energy Authority, Cairo (Egypt)

    1996-03-01

    The phosphate ores used at `Abu zaabal fertilizer and chemical company` for the production of some chemicals and fertilizers contain detectable amounts of uranium. In this study, the content of uranium in samples of different products of fertilizers, gypsum, and phosphate ore were determined using NAA, and gamma ray spectroscopy of the irradiated samples. Another method based on measuring the natural radioactivity of {sup 238} U series for non-irradiated samples using gamma-ray spectroscopy was also used for determine uranium content in the samples. In the NAA method, the content of U(ppm) in the samples was been computed from the photopeak activity of the lines = 106.1, 228.2, and 277.5 KeV of {sup 239} Np induced in the irradiated samples, and the uranium standard simultaneously irradiated. the gamma-ray spectra, and the decay curves are given. In the second method the gamma-ray spectra of the natural radioactivity of the samples and uranium standard were measured. The gamma-transition of energies 295.1, 251.9 KeV for {sup 214} Pb; 609.3, 768.4, 1120.3, 1238.1 KeV for {sup 214} Bi were determined. The uranium {sup 23U} traces in drainage water was also determined spectrophotometrically using arsenazo-III after preconcentration of uranium from the pretreated drainage water in column packed with chelex-100 resin. The recovery was found to be 90 {+-} 5%. 11 figs., 3 tabs.

  11. Environmental conditioning on uranium surface distribution in the tropical region

    International Nuclear Information System (INIS)

    Silva, Heitor Evangelista da; Licinio, Marcus V.S.; Miranda, Marcio R.

    2001-01-01

    Based on a high resolution aerogammaspectrometer survey over the State of Rio de Janeiro, it is presented an associative study of equivalent uranium concentration and environmental parameters. The aspects considered in this study included geological domains like Sandys, Gnaisses, Granites, Xists; soils domains like Organic and Alluvial ones, Litolic, Glei, Podzolic, Red-yellow, Latossolo, Planossolo, Red bruizem, Cambissolo, Hidromorphic Podzol, Yellow latossolo; geomorphology (Coast Plains and River Accumulation Land, Coast Tabulators, Pomba-Muriae Rivers Spread Depression, Northern Mantiqueira, main Hills and Coastal Rock Massifs, Steep slopes and Reverses of Serra do Mar Mountain Range ,Serra dos Orgaos Mountain Range and Bocaina Tablelands), Paraiba do Sul Crests Alignment, Medium Paraiba do Sul Depression); influence of mean annual rain intensity and hydrographical categories were also evaluated. Geoprocessing of each environmental data base at the same cartographical base of uranium surface distribution was the basic methodology employed. (author)

  12. Using Environmental Variables for Studying of the Quality of Sampling in Soil Mapping

    Directory of Open Access Journals (Sweden)

    A. Jafari

    2016-02-01

    Full Text Available Introduction: Methods of soil survey are generally empirical and based on the mental development of the surveyor, correlating soil with underlying geology, landforms, vegetation and air-photo interpretation. Since there are no statistical criteria for traditional soil sampling; this may lead to bias in the areas being sampled. In digital soil mapping, soil samples may be used to elaborate quantitative relationships or models between soil attributes and soil covariates. Because the relationships are based on the soil observations, the quality of the resulting soil map depends also on the soil observation quality. An appropriate sampling design for digital soil mapping depends on how much data is available and where the data is located. Some statistical methods have been developed for optimizing data sampling for soil surveys. Some of these methods deal with the use of ancillary information. The purpose of this study was to evaluate the quality of sampling of existing data. Materials and Methods: The study area is located in the central basin of the Iranian plateau (Figure 1. The geologic infrastructure of the area is mainly Cretaceous limestone, Mesozoic shale and sandstone. Air photo interpretation (API was used to differentiate geomorphic patterns based on their formation processes, general structure and morphometry. The patterns were differentiated through a nested geomorphic hierarchy (Fig. 2. A four-level geomorphic hierarchy is used to breakdown the complexity of different landscapes of the study area. In the lower level of the hierarchy, the geomorphic surfaces, which were formed by a unique process during a specific geologic time, were defined. A stratified sampling scheme was designed based on geomorphic mapping. In the stratified simple random sampling, the area was divided into sub-areas referred to as strata based on geomorphic surfaces, and within each stratum, sampling locations were randomly selected (Figure 2. This resulted in 191

  13. Surface Water Sampling Data for BP Spill/Deepwater Horizon

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Deepwater Horizon oil spill (also referred to as the BP oil spill) began on 20 April 2010 in the Gulf of Mexico on the BP-operated Macondo Prospect. Following...

  14. Simultaneous determination of plutonium and uranium in environmental samples

    International Nuclear Information System (INIS)

    Jiao Shufen

    1993-01-01

    Plutonium and uranium in a plant sample ash was simultaneously determined by using anion exchange resin columns, and concentrated hydrochloric acid and nitric acid. At the final stage of the determination of the nuclides, each of them was electrodeposited together with a little amount of molybdenum carrier onto a stainless steel plate and measured by α-ray spectrometer. The recoveries of uranium and plutonium from the plant samples determined by adding internal standard 236 Pu which was 100% and 63%, respectively

  15. Evaluating the reproducibility of environmental radioactivity monitoring data through replicate sample analysis

    International Nuclear Information System (INIS)

    Lindeken, C.L.; White, J.H.; Silver, W.J.

    1978-01-01

    At the Lawrence Livermore Laboratory, about 10% of the sampling effort in the environmental monitoring program represents replicate sample collection. Replication of field samples was initiated as part of the quality assurance program for environmental monitoring to determine the reproducibility of environmental measurements. In the laboratory these replicates are processed along with routine samples. As all components of variance are included in analysis of such field samples, comparison of the analytical data from replicate analyses provides a basis for estimating the overall reproducibility of the measurements. The replication study indicates that the reproducibility of environmental radioactivity monitoring data is subject to considerably more variability than is indicated by the accompanying counting errors. The data are also compared with analyses of duplicate aliquots from a well mixed sample or with duplicate aliquots of samples with known radionuclide content. These comparisons show that most of the variability is associated with the collection and preparation of the sample rather than with the analytical procedures

  16. The application of x-ray fluorescence and diffraction to the characterization of environmental assessment samples

    International Nuclear Information System (INIS)

    Censullo, A.C.; Briden, F.E.

    1982-01-01

    Some of the results of tests on environmental assessment samples are reported on. The utility of the J.W. Criss fundamental parameters computer program is evaluated for samples in which only one standard per element was used and where the standard matrix did not strictly resemble the unknown matrix. The environmental significance of a sample is dependent not only on its elemental composition, but also on the species or phases which the elements comprise. X-ray powder diffraction may be used to advantage for speciation. Multi-phase environmental assessment samples are amenable to XRD interpretation. Some results of the application of the Joint Committee on Power Diffraction Standards computer interpretatin of typical environmental samples are discussed. They were shown to contribute to the specification of the complex samples that are encountered in environmental assessments

  17. 40 CFR 761.306 - Sampling 1 meter square surfaces by random selection of halves.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Sampling 1 meter square surfaces by...(b)(3) § 761.306 Sampling 1 meter square surfaces by random selection of halves. (a) Divide each 1 meter square portion where it is necessary to collect a surface wipe test sample into two equal (or as...

  18. Adaptive maximal poisson-disk sampling on surfaces

    KAUST Repository

    Yan, Dongming; Wonka, Peter

    2012-01-01

    In this paper, we study the generation of maximal Poisson-disk sets with varying radii on surfaces. Based on the concepts of power diagram and regular triangulation, we present a geometric analysis of gaps in such disk sets on surfaces, which

  19. Middlesex Sampling Plant [MSP] annual site environmental report, calendar year 1988

    International Nuclear Information System (INIS)

    1989-04-01

    The environmental monitoring program, which began in 1980, was continued in 1988 at the former Middlesex Sampling Plant (MSP) site, located in the Borough of Middlesex, New Jersey. The MSP site is part of the Formerly Utilized Site Remedial Action Program (FUSRAP), a Department of Energy (DOE) program to decontaminate or otherwise control sites where residual radioactive materials remain either from the early years of the nation's atomic energy program or from commercial operations causing conditions that Congress has mandated DOE to remedy. The environmental monitoring program is carried out by Bechtel National, Inc. (BNI), project management contractor for FUSRAP. The monitoring program at the MSP measures radon concentrations in air; external gamma radiation levels; and uranium and radium concentrations in surface water, groundwater, and sediment. To verify that the site is in compliance with the DOE radiation protection standard (100 mrem/yr) and to assess its potential effect on public health, the radiation dose was calculated for a hypothetical maximally exposed individual. Results of the 1988 monitoring show that the MSP is in compliance with applicable DOE radiation protection standards and with applicable requirements specified by New Jersey Department of Environmental Protection groundwater permits. 17 refs., 15 figs., 21 tabs

  20. Survival and detection of rotaviruses on environmental surfaces in day care centers.

    Science.gov (United States)

    Keswick, B H; Pickering, L K; DuPont, H L; Woodward, W E

    1983-01-01

    Previously, we demonstrated that children in day care centers commonly experience diarrhea due to rotavirus, giardia, and bacterial pathogens. Multiple agents frequently coexist, and the environment is heavily contaminated with enteric bacteria during outbreaks. A study of environmental surface contamination with rotavirus was performed during three non-outbreak periods. Of 25 samples collected from environmental surfaces and teachers hands at a day care center, 4 (16%) were positive for rotavirus antigen when a fluorescence assay was used. We also examined the survival of two animal viruses, rotavirus SA-11 and poliovirus type 1, and bacteriophage 12 on similar environmental surfaces in a laboratory. Poliovirus type 1 and bacteriophage f2 were more resistant to drying than rotavirus SA-11 and could be recovered after a 90-min exposure on a dry surface. Rotavirus SA-11 could be detected for 30 min. All three viruses survived longer when they were suspended in fecal material than when they were suspended in distilled water. These data suggest that several agents, including rotavirus, can remain viable on contaminated surfaces long enough to be transmitted to susceptible children. This finding helps explain why rotavirus shows a mode of spread like that of parasitic and bacterial agents within day care center settings. PMID:6314896

  1. Adsorption of aromatic hydrocarbons and ozone at environmental aqueous surfaces.

    Science.gov (United States)

    Vácha, Robert; Cwiklik, Lukasz; Rezác, Jan; Hobza, Pavel; Jungwirth, Pavel; Valsaraj, Kalliat; Bahr, Stephan; Kempter, Volker

    2008-06-05

    Adsorption of environmentally important aromatic molecules on a water surface is studied by means of classical and ab initio molecular dynamics simulations and by reflection-absorption infrared spectroscopy. Both techniques show strong activity and orientational preference of these molecules at the surface. Benzene and naphthalene, which bind weakly to water surface with a significant contribution of dispersion interactions, prefer to lie flat on water but retain a large degree of orientational flexibility. Pyridine is more rigid at the surface. It is tilted with the nitrogen end having strong hydrogen bonding interactions with water molecules. The degree of adsorption and orientation of aromatic molecules on aqueous droplets has atmospheric implications for heterogeneous ozonolysis, for which the Langmuir-Hinshelwood kinetics mechanism is discussed. At higher coverages of aromatic molecules the incoming ozone almost does not come into contact with the underlying aqueous phase. This may rationalize the experimental insensitivity of the ozonolysis on the chemical nature of the substrate on which the aromatic molecules adsorb.

  2. 3D topography for environmentally friendly machined surfaces

    International Nuclear Information System (INIS)

    Dudas, I; Varga, G

    2005-01-01

    Nowadays more and more scientific paper deals with drilling. In recent years there have been limited changes to the drill design but considerable improvements have been made in the selection of drill materials, drill coatings, flute design and the cutting fluid guiding methods. All of these improvements have been introduced to improve the surface finish of the drilled hole, reduce the energy during drilling process and to reduce ecological damage to the cutting fluids, which carry away heat and debris from the cutting zone. The paper briefly describes the development of surface characterization to its current 3D capability. It shows how selected parameters can assist with drill process analysis and how this can be supported through the introduction of the planned new ISO International Standard for 3D surface characterization. The paper is supported by a sample-drilling test to demonstrate the power of the proposed analysis

  3. Investigation of environmental samples by low-level gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, M [Nuclear Engineering and Analytics Rossendorf, Inc., Dresden (Germany); Niese, S [Nuclear Engineering and Analytics Rossendorf, Inc., Dresden (Germany)

    1997-03-01

    The average sample number in our laboratory is about 200 per month (12% technical solid state, 30% geological solid state, 6% geological solid state with low mass, 12% biological, 11% water directly, 25% water after chemical separation, 4% others). In 54% of the measurements the background continuum, and though the detection limit, is determined only by the detector himself and not by the compton continuum from high energy lines in the sample. Some examples in the presented work aim to prove the advantages of gamma ray spectrometry in the underground laboratory Felsenkeller. (orig./DG)

  4. Natural and anthropogenic {sup 236}U in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Steier, Peter [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria)], E-mail: peter.steier@univie.ac.at; Bichler, Max [Atominstitut der Osterreichischen Universitaeten, Technische Universitaet Wien, Stadionallee 2, Wien A-1020 (Austria); Keith Fifield, L. [Department of Nuclear Physics, RSPhysSE, Australian National University, Canberra, ACT 0200 (Australia); Golser, Robin; Kutschera, Walter; Priller, Alfred [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria); Quinto, Francesca [Dipartimento di Scienze Ambientali, Seconda Universita di Napoli, via Vivaldi 43, Caserta 81100 (Italy); Richter, Stephan [Euopean Commission, Directorate-General Joint Research Centre, Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, B-2440 Geel (Belgium); Srncik, Michaela [Institut fuer Anorganische Chemie, Universitaet Wien, Waehringer Strasse 42, A-1090 Wien (Austria); Terrasi, Philippo [Dipartimento di Scienze Ambientali, Seconda Universita di Napoli, via Vivaldi 43, Caserta 81100 (Italy); Wacker, Lukas [Institute for Particle Physics, HPK H25, Schafmattstrasse 20, CH-8093 Zuerich (Switzerland); Wallner, Anton [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria); Wallner, Gabriele [Institut fuer Anorganische Chemie, Universitaet Wien, Waehringer Strasse 42, A-1090 Wien (Austria); Wilcken, Klaus M. [Scottish Universities Environmental Research Centre, Scottish Enterprise Technology Park, East Kilbride G75 OQF (United Kingdom); Maria Wild, Eva [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria)

    2008-05-15

    The interaction of thermal neutrons with {sup 235}U results in fission with a probability of {approx}85% and in the formation of {sup 236}U (t{sub 1/2} = 2.3 x 10{sup 7} yr) with a probability of {approx}15%. While anthropogenic {sup 236}U is, therefore, present in spent nuclear fuel at levels of {sup 236}U/U up to 10{sup -2}, the expected natural ratios in the pre-anthropogenic environment range from 10{sup -14} to 10{sup -10}. At VERA, systematic investigations suggest a detection limit below {sup 236}U/U = 5 x 10{sup -12} for samples of 0.5 mg U, while chemistry blanks of {approx}2 x 10{sup 7} atoms {sup 236}U per sample limit the sensitivity for smaller samples. We have found natural isotopic ratios in uranium reagents separated before the onset of human nuclear activities, in uranium ores from various origins and in water from a subsurface well in Bad Gastein, Austria. Anthropogenic contamination was clearly visible in soil and rivulet samples from Salzburg, Austria, whereas river sediments from Garigliano river (Southern Italy) were close to the detection limit. Finally, our natural in-house standard Vienna-KkU was calibrated against a certified reference material (IRMM REIMEP-18 A)

  5. Filtration recovery of extracellular DNA from environmental water samples

    Science.gov (United States)

    qPCR methods are able to analyze DNA from microbes within hours of collecting water samples, providing the promptest notification and public awareness possible when unsafe pathogenic levels are reached. Health risk, however, may be overestimated by the presence of extracellular ...

  6. Total Decomposition of Environmental Radionuclide Samples with a Microwave Oven

    International Nuclear Information System (INIS)

    Ramon Garcia, Bernd Kahn

    1998-01-01

    Closed-vessel microwave assisted acid decomposition was investigated as an alternative to traditional methods of sample dissolution/decomposition. This technique, used in analytical chemistry, has some potential advantages over other procedures. It requires less reagents, it is faster, and it has the potential of achieving total dissolution because of higher temperatures and pressures

  7. GY SAMPLING THEORY IN ENVIRONMENTAL STUDIES 2: SUBSAMPLING ERROR MEASUREMENTS

    Science.gov (United States)

    Sampling can be a significant source of error in the measurement process. The characterization and cleanup of hazardous waste sites require data that meet site-specific levels of acceptable quality if scientifically supportable decisions are to be made. In support of this effort,...

  8. Hypercrosslinked particles for the extraction of sweeteners using dispersive solid-phase extraction from environmental samples.

    Science.gov (United States)

    Lakade, Sameer S; Zhou, Qing; Li, Aimin; Borrull, Francesc; Fontanals, Núria; Marcé, Rosa M

    2018-04-01

    This work presents a new extraction material, namely, Q-100, based on hypercrosslinked magnetic particles, which was tested in dispersive solid-phase extraction for a group of sweeteners from environmental samples. The hypercrosslinked Q-100 magnetic particles had the advantage of suitable pore size distribution and high surface area, and showed good retention behavior toward sweeteners. Different dispersive solid-phase extraction parameters such as amount of magnetic particles or extraction time were optimized. Under optimum conditions, Q-100 showed suitable apparent recovery, ranging in the case of river water sample from 21 to 88% for all the sweeteners, except for alitame (12%). The validated method based on dispersive solid-phase extraction using Q-100 followed by liquid chromatography with tandem mass spectrometry provided good linearity and limits of quantification between 0.01 and 0.1 μg/L. The method was applied to analyze samples from river water and effluent wastewater, and four sweeteners (acesulfame, saccharin, cyclamate, and sucralose) were found in both types of sample. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Distribution of {sup 90}Sr activities in the environmental radiation samples of Jeju Island, Korea

    Energy Technology Data Exchange (ETDEWEB)

    Han, Chung Hun; Park, Youn Hyun; Lee, Young Gyu; Park, Jae Woo [Jeju National University, Jeju (Korea, Republic of)

    2016-12-15

    This work was to get information about {sup 90}Sr contamination of the environment by using soil and moss from selected areas in Jeju Island, Korea. The activities of {sup 90}Sr in soil and moss samples were investigated at nine locations of Jeju island, Korea. The soil samples have been collected at 4 sites of Jeju island during June to August of 2013, analyzed for vertical distribution of {sup 90}Sr activities. The moss samples have been collected at 5 sites of Jeju island during November of 2011 to June of 2012, and analyzed for radioactive {sup 90}Sr. The {sup 90}Sr vertical concentrations in the investigated soil samples were 2.77 to 18.24 Bq·kg{sup -1} in eastern part, 1.69 to 18.27 Bq·kg{sup -1} in northern part, 3.76 to 13.46 Bq·kg{sup -1} in the western part and 1.09 to 8.70 Bq·kg{sup -1} in the southern part of the Mt. Halla in Jeju island, respectively. Activities of {sup 90}Sr show the highest value at the surface soil and decrease with depth. The activity concentration measured was in the range of 79.6 to 363 Bq·kg{sup -1} -dry moss. This material is expected to be basis reference for survey of environmental radioactivity in Jeju Island.

  10. ICP-MS applications for the analysis of geological materials and environmental samples

    International Nuclear Information System (INIS)

    Bendl, J.

    1997-01-01

    This work deals with applications of inductively coupled plasma - mass spectrometry applications for the analysis of geological materials and environmental samples. There are instrumentation, calibration, alternatives of sample introduction, interferences, trace elements analysis, rare earth elements and uranium and thorium, precious metals, isotopic analysis and environmental analysis discussed

  11. Surface plasmon resonance biosensors for highly sensitive detection in real samples

    Science.gov (United States)

    Sepúlveda, B.; Carrascosa, L. G.; Regatos, D.; Otte, M. A.; Fariña, D.; Lechuga, L. M.

    2009-08-01

    In this work we summarize the main results obtained with the portable surface plasmon resonance (SPR) device developed in our group (commercialised by SENSIA, SL, Spain), highlighting its applicability for the real-time detection of extremely low concentrations of toxic pesticides in environmental water samples. In addition, we show applications in clinical diagnosis as, on the one hand, the real-time and label-free detection of DNA hybridization and single point mutations at the gene BRCA-1, related to the predisposition in women to develop an inherited breast cancer and, on the other hand, the analysis of protein biomarkers in biological samples (urine, serum) for early detection of diseases. Despite the large number of applications already proven, the SPR technology has two main drawbacks: (i) not enough sensitivity for some specific applications (where pM-fM or single-molecule detection are needed) (ii) low multiplexing capabilities. In order solve such drawbacks, we work in several alternative configurations as the Magneto-optical Surface Plasmon Resonance sensor (MOSPR) based on a combination of magnetooptical and ferromagnetic materials, to improve the SPR sensitivity, or the Localized Surface Plasmon Resonance (LSPR) based on nanostructures (nanoparticles, nanoholes,...), for higher multiplexing capabilities.

  12. FLOQSwabTM: optimisation of procedures for the recovery of microbiological samples from surfaces

    Directory of Open Access Journals (Sweden)

    Guido Finazzi

    2016-08-01

    Full Text Available The FLOQSwabTM is a specimen collection device worldwide recognised for its superior performance in the clinical diagnostics. The aim of this work was to evaluate FLOQSwabTM for the recovery of microbiological samples from surfaces compared to the traditional swab (rayon tipped swab as per ISO 18593:2004 standard. The FLOQSwabTM, thanks to its innovative manufacturing technology, allows improving the efficiency of recovery and release of analyte. The study has been divided into two experiments. In the first experiment the two swabs were evaluated for their capacity to recover and release the analyte (three different bacterial loads of Escherichia coli. In the second experiment, the two swabs were evaluated for their capacity to recover three different bacterial loads of E. coli from two different surface materials (stainless steel and polypropylene. In all experiments the flocked swab demonstrated a higher recovery rate compared to the traditional rayon tipped swab. The data obtained from this preliminary study demonstrated that the FLOQSwabTM could be a good food surfaces collection device, which improves the recovery of the analyte and thus produces accurate results. Based on the outcomes of the study, a larger field study is in progress using the FLOQSwabTM for samples collection to improve both environmental monitoring and the efficacy of the hygiene controls for food safety.

  13. The sampling and analysing methods of radionuclides used in the Nordic countries for environmental samples

    International Nuclear Information System (INIS)

    Taipale, Tarja K.

    1985-01-01

    The Radioecology Group under the Nordic Liaison Committee for Atomic Energy has considered it to be of great importance to improve the comparability of environmental radioactivity measurements in the Nordic countries, a basic requirement for co-ordinated research programmes. In case of emergency, good comparability between the results obtained will be required for mutual assistance. Therefore several intercomparison exercises have been carried out between the laboratories measuring environmental radioactivity. The exercises have proved very useful and have led to a more comprehensive and systematic survey of the environmental measurement methodology used so far by the Nordic laboratories. Furthermore it is considered necessary to make some recommendations or even to reach an agreement on how to present the results in order to make the comparison of, at least, monitoring data easier. This report is based on the answers received from the participating laboratories to a questionnaire sent by the Finnish Centre for Radiation and Nuclear Safety, Helsinki

  14. The sampling and analysing methods of radionuclides used in the Nordic countries for environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Taipale, Tarja K [ed.

    1985-01-01

    The Radioecology Group under the Nordic Liaison Committee for Atomic Energy has considered it to be of great importance to improve the comparability of environmental radioactivity measurements in the Nordic countries, a basic requirement for co-ordinated research programmes. In case of emergency, good comparability between the results obtained will be required for mutual assistance. Therefore several intercomparison exercises have been carried out between the laboratories measuring environmental radioactivity. The exercises have proved very useful and have led to a more comprehensive and systematic survey of the environmental measurement methodology used so far by the Nordic laboratories. Furthermore it is considered necessary to make some recommendations or even to reach an agreement on how to present the results in order to make the comparison of, at least, monitoring data easier. This report is based on the answers received from the participating laboratories to a questionnaire sent by the Finnish Centre for Radiation and Nuclear Safety, Helsinki.

  15. Resonance ionization mass spectrometry system for measurement of environmental samples

    International Nuclear Information System (INIS)

    Pibida, L.; McMahon, C.A.; Noertershaeuser, W.; Bushaw, B.A.

    2002-01-01

    A resonance ionization mass spectrometry (RIMS) system has been developed at the National Institute of Standards and Technology (NIST) for sensitive and selective determination of radio-cesium in the environment. The overall efficiency was determined to be 4x10-7 with a combined (laser and mass spectrometer) selectivity of 108 for both 135Cs and 137Cs with respect to 133Cs. RIMS isotopic ratio measurements of 135Cs/ 137Cs were performed on a nuclear fuel burn-up sample and compared to measurements on a similar system at Pacific Northwest National Laboratory (PNNL) and to conventional thermal ionization mass spectrometry (TIMS). Results of preliminary RIMS investigations on a freshwater lake sediment sample are also discussed

  16. Application of WSP method in analysis of environmental samples

    International Nuclear Information System (INIS)

    Stacho, M.; Slugen, V.; Hinca, R.; Sojak, S.; Krnac, S.

    2014-01-01

    Detection of activity in natural samples is specific especially because of its low level and high background interferences. Reduction of background interferences could be reached using low background chamber. Measurement geometry in shape of Marinelli beaker is commonly used according to low level of activity in natural samples. The Peak Net Area (PNA) method is the world-wide accepted technique for analysis of gamma-ray spectra. It is based on the net area calculation of the full energy peak, therefore, it takes into account only a fraction of measured gamma-ray spectrum. On the other hand, the Whole Spectrum Processing (WSP) approach to the gamma analysis makes possible to use entire information being in the spectrum. This significantly raises efficiency and improves energy resolution of the analysis. A principal step for the WSP application is building up the suitable response operator. Problems are put in an appearance when suitable standard calibration sources are unavailable. It may be occurred in the case of large volume samples and/or in the analysis of high energy range. Combined experimental and mathematical calibration may be a suitable solution. Many different detectors have been used to register the gamma ray and its energy. HPGe detectors produce the highest resolution commonly available today. Therefore they are they the most often used detectors in natural samples activity analysis. Scintillation detectors analysed using PNA method could be also used in simple cases, but for complicated spectra are practically inapplicable. WSP approach improves resolution of scintillation detectors and expands their applicability. WSP method allowed significant improvement of the energetic resolution and separation of "1"3"7Cs 661 keV peak from "2"1"4Bi 609 keV peak. At the other hand the statistical fluctuations in the lower part of the spectrum highlighted by background subtraction causes that this part is still not reliably analyzable. (authors)

  17. Self-attenuation of gamma rays during radioactivity concentration analysis of environmental samples

    International Nuclear Information System (INIS)

    Watson, D.; Dharmasiri, J.; Akber, R.

    2001-01-01

    Gamma spectroscopy using HPGe detector systems is a readily used technique for routine analysis of radioactivity in environmental samples. The systems are generally calibrated using standards of known radioactivity and composition. Radioactivity in environmental samples is generally distributed in the bulk of the material. When a sample of finite thickness is analysed through gamma spectroscopy, a proportion of the gamma rays emitted from the sample is either stopped or scattered from the sample material itself. These processes of self-absorption and self-attenuation depend upon the physical and elemental composition of the sample and the energy of the gamma radiation. Since environmental samples vary in composition, instrument calibration using a fixed matrix composition may not be valid for a diversity of samples. We selected and analysed five sample matrices to investigate the influence of self-absorption and self-attenuation in environmental samples. Our selection consisted of bentonite and kaolin representing clay, quartz representing silica, ash representing prepared biota, and analytical grade MnO 2 representing a co-precipitant used for extractive radioactivity from aqueous samples. Our findings show that within 5% of uncertainty the silica based standards can be used to cover the environmental samples of varying clay (silica content). The detection efficiency for ash and MnO 2 could be different particularly in the 30 - 100 keV energy range. The differences in sample behaviour can be explained on the basis of atomic number, mass number and density

  18. Guidance for establishment and implementation of a national sample management program in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-01-01

    The role of the National Sample Management Program (NSMP) proposed by the Department of Energy's Office of Environmental Management (EM) is to be a resource for EM programs and for local Field Sample Management Programs (FSMPs). It will be a source of information on sample analysis and data collection within the DOE complex. Therefore the NSMP's primary role is to coordinate and function as a central repository for information collected from the FSMPs. An additional role of the NSMP is to monitor trends in data collected from the FSMPs over time and across sites and laboratories. Tracking these trends will allow identification of potential problems in the sampling and analysis process

  19. Evaluation of different methods to recover methicillin-resistant Staphylococcus aureus from hospital environmental surfaces.

    LENUS (Irish Health Repository)

    Dolan, A

    2011-11-01

    The environment is implicated as a source of healthcare-associated infections (HAIs) and there is a need for evidence-based approaches to environmental sampling to assess cleanliness and improve infection prevention and control. We assessed, in vitro, different approaches to sampling the environment for meticillin-resistant Staphylococcus aureus (MRSA). In a laboratory-based investigation, the recovery of MRSA from two common hospital environments using six different sampling methods was evaluated, with a wild-type strain of MRSA. A 100 cm(2) section of mattress and a laboratory bench surface were contaminated with known inocula of MRSA. Bacteria were recovered by sampling at 30 min after inoculation, using either saline-moistened cotton swabs, neutralising buffer swabs, eSwabs or macrofoam swabs, which were all enriched in tryptone soya broth, or by sampling with direct contact plates or chromogenic \\'sweep\\' plates. The sensitivity (i.e. the minimum number of bacteria inoculated on to a surface which subsequently produced a positive result) of each method was determined for each surface. The most sensitive methods were eSwabs and macrofoam swabs, requiring 6.1 × 10(-1) and 3.9 × 10(-1) MRSA\\/cm(2), respectively, to produce a positive result from the bench surface. The least sensitive swabbing method was saline-moistened cotton swabs, requiring 1.1 × 10(3) MRSA\\/cm(2) of mattress. The recovery of bacteria from environmental samples varies with the swabs and methodology used and negative culture results do not exclude a pathogen-free environment. Greater standardisation is required to facilitate the assessment of cleanliness of healthcare environments.

  20. Environmental Sampling FY03 Annual Report - Understanding the Movement of Mercury on the INEEL

    International Nuclear Information System (INIS)

    Michael L. Abbott

    2003-01-01

    Environmental mercury measurements were started in Fy-01 at the Idaho National Engineering Laboratory (INEEL) to monitor downwind impacts from on-going waste treatment operations at the Idaho Nuclear Technology and Engineering Center (INTEC) and to improve our scientific understanding of mercury fate and transport in this region. This document provides a summary of the sampling done in FY04. Continuous total gaseous mercury (TGM) measurements were made using a Tekran Model 2537A mercury vapor analyzer during October 2002 and from February through July 2003. The equipment was deployed in a self-contained field trailer at the Experimental Field Station (EFS) four kilometers downwind (northeast) of INTEC. Mercury surface-to-air flux measurements were made in October 2002 and from February through May 2003 to better understand the fate of the estimated 1500 kg of mercury emitted from 36 years of calciner operations at INTEC and to improve our scientific understanding of mercury environmental cycling in this region. Flux was measured using an INEEL-designed dynamic flux chamber system with a Tekran automated dual sampling (TADS) unit. Diel flux was positively correlated with solar radiation (r = 0.65), air temperature (r = 0.64), and wind speed (r = 0.38), and a general linear model for flux prediction at the INEEL was developed. Reactive gaseous mercury (RGM) was measured at EFS in July using a Tekran Model 1130 mercury speciation unit. Based on comparisons with other published data around the U.S., mercury air concentrations and surface flux rates directly downwind from INTEC were not distinguishable from remote area (non-industrial) background levels during the monitoring period

  1. Specific activity of 129I in environmental samples

    International Nuclear Information System (INIS)

    Ravi, P.M.; Iyer, M.R.; Bhat, I.S.; Somasundaram, S.; Subramanian, M.S.

    1988-01-01

    129 I finds its way into the environment as a result of man-made nuclear operations. It is also formed by the interaction of cosmic rays with xenon isotopes and spontaneous fission of naturally occurring uranium. 129 I and stable 127 I contents of thyroid, milk, seaweed and aplysia cell samples collected from around a fuel reprocessing plant were estimated by neutron activation analysis method. The annual 129 I intake of an individual works out to be about 0.3 Bq as compared to the natural radioactivity content in human body of about 5000 Bq. (author). 3 tabs

  2. Data Validation Package - June 2016 Groundwater and Surface Water Sampling at the Green River, Utah, Disposal Site

    Energy Technology Data Exchange (ETDEWEB)

    Linard, Joshua [USDOE Office of Legacy Management, Washington, DC (United States); Price, Jeffrey [Navarro Research and Engineering, Inc., Las Vegas, NV (United States)

    2016-10-10

    This event included annual sampling of groundwater and surface water locations at the Green River, Utah, Disposal Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for US. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lrnldownloads/sampling-and- analysis-plan-us-department-energy-office-legacy-management-sites). Samples were collected from 15 monitoring wells and two surface locations at the disposal site as specified in the draft 2011 Ground Water Compliance Action Plan for the Green River, Utah, Disposal Site. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. A duplicate sample was collected from location 0179. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. See Attachment 2, Trip Reports for additional details. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that requires additional action or follow-up.

  3. Samples of Asteroid Surface Ponded Deposits in Chondritic Meteorites

    Science.gov (United States)

    Zolensky, M. E.; Lee, R.; Le, L.

    2004-01-01

    One of the many unexpected observations of asteroid 433 Eros by the Near Earth Asteroid Rendezvous (NEAR) mission was the many ponds of fine-grained materials [1-3]. The ponds have smooth surfaces, and define equipotential surfaces up to 10's of meters in diameter [4]. The ponds have a uniformly sub-cm grain size and appear to be cohesive or indurated to some degree, as revealed by slumping. The ponds appear to be concentrated within 30 degrees of the equator of Eros, where gravity is lowest. There is some insight into the mineralogy and composition of the ponds surfaces from NEAR spectroscopy [2,4,5,6]. Compared to the bulk asteroid, ponds: (1) are distinctly bluer (high 550/760 nm ratio), (2) have a deeper 1um mafic band, (3) have reflectance elevated by 5%.

  4. PFAS methods and guidance for sampling and analyzing water and other environmental media (Technical Brief)

    Science.gov (United States)

    EPA's methods for analyzing PFAS in environmental media are in various stages of development. This fact sheet summarizes EPA's analytical methods development for groundwater, surface water, wastewater, and solids, including soils, sediments, and biosolids

  5. PIXE analysis of marine environmental samples from the Pacific Ocean

    International Nuclear Information System (INIS)

    Miyake, Hiroshi; Matsuda, Yasuhiro; Shitashima, Kiminori; Tsubota, Hiroyuki.

    1990-01-01

    Aerosol samples from the western North Pacific Ocean are collected during a cruise of R/V Hakuhomaru from Japan to Hawaii and they are analyzed by PIXE (particle induced X-ray emission). Concentrations of radon daughters are measured with CR-39 track detectors mounted on the impactor to estimate the transport time of air mass from the Asian Continent. Distributions of particulate element concentrations clearly demonstrate the influence of the westerlies. Strong correlations are observed between fine sulphur concentrations and those of heavy metals such as Fe and Zn. Vertical profiles of heavy metal elements contained in marine particulates are also investigated at a trench in the Pacific Ocean and basins in the Japan Sea. Particulate element concentrations determined by PIXE agree well with those determined by chemical analysis of filtered/total water. Remarkable changes in depth profiles of particulate manganese are observed at the trench, which suggest horizontal transport of marine particulates from the trench wall. (N.K.)

  6. A note on {sup 207}Bi in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Bossew, P. [European Commission, DG Joint Research Centre, Institute of Environment and Sustainability, Radioactivity Environmental Monitoring Group. Via Fermi 1, I-21020 Ispra, Vatican City State, Holy See (Italy)]. E-mail: peter.bossew@jrc.it; Lettner, H. [Institute of Physics and Biophysics, University of Salzburg, Hellbrunner Strasse 34, A-5020 Salzburg (Austria)]. E-mail: herbert.lettner@sbg.ac.at; Hubmer, A. [Institute of Physics and Biophysics, University of Salzburg, Hellbrunner Strasse 34, A-5020 Salzburg (Austria)

    2006-07-01

    Traces of the radionuclide {sup 207}Bi were identified in soil and cryoconite (glacier sediment) samples from Alpine regions of Austria. This nuclide has been produced in thermonuclear explosions mainly in the early 1960s and subsequently dispersed in the atmosphere. Activity concentrations up to 22 Bq/kg d.m. have been found. The ratio {sup 207}Bi:{sup 137}Cs(global fallout) equals (1.70 {+-} 0.12)10{sup -3}, which is in accordance with literature data. When low levels of {sup 207}Bi are assessed by gamma spectrometry, corrections must be made for a gamma line produced in the lead shield by neutron activation due to cosmic neutrons.

  7. Pursuit of improvement in uranium bulk analysis at the clear facility for safeguards environmental samples

    International Nuclear Information System (INIS)

    Sakurai, S.; Takahashi, M.; Sakakibara, T.; Magara, M.; Kurosawa, S.; Esaka, F.; Takai, K.; Watanabe, K.; Usuda, S.; Adachi, T.

    2002-01-01

    Full text: In order to contribute to the IAEA strengthened safeguards system, a project started in Japan Atomic Energy Research Institute (JAERI) in 1998. Consequently, a clean room facility called as CLEAR, the Clean Laboratory for Environmental Analysis and Research, was constructed in June 2001 at JAERI Tokai and the analytical techniques of ultra-trace nuclear materials in environmental samples are being developed. As for the bulk analysis, performance of inductively-coupled plasma mass spectrometry (ICP-MS) was mainly examined because sample preparation for ICP-MS is simpler than that for thermal ionization mass spectrometry (TIMS). Interference of polyatomic ion (such as PtAr + ) and coexisting element (such as Na) on the uranium ions, as well as mass bias caused by ICP-MS operating conditions, has been investigated for precise measurement on uranium isotope ratio. The authors have also studied on the uranium blanks during sample treatment process. The blank value below 10 pg uranium per sample treatment was obtained: dominant origins were elution from Teflon vessel surface in acid heating process of the sample to dry up. The work is in progress to minimize the blank. Compared with the process blank and the minimum uranium amount for isotope ratio measurement by ICP-MS (ca. 10 pg for natural uranium), the swipe cotton (Texwipe-304) which is currently used for IAEA Environmental Sampling includes much more amount of natural uranium in several nano-grams. If the amount of uranium collected on Texwipe-304 is small, sensitive and reliable measurement on isotope ratio will be impossible by bulk analysis. The authors are seeking alternative swipe materials with less amount of uranium. Recently, one of the authors devised an effective technique for recovery of uranium-containing particles from Texwipe-304. The technique, named as Vacuum Suction Method, uses a combination of polycarbonate membrane filters and a macro-pipette tip, which is connected to a vacuum pump

  8. Combined Contamination and Space Environmental Effects on Solar Cells and Thermal Control Surfaces

    Science.gov (United States)

    Dever, Joyce A.; Bruckner, Eric J.; Scheiman, David A.; Stidham, Curtis R.

    1994-01-01

    For spacecraft in low Earth orbit (LEO), contamination can occur from thruster fuel, sputter contamination products and from products of silicone degradation. This paper describes laboratory testing in which solar cell materials and thermal control surfaces were exposed to simulated spacecraft environmental effects including contamination, atomic oxygen, ultraviolet radiation and thermal cycling. The objective of these experiments was to determine how the interaction of the natural LEO environmental effects with contaminated spacecraft surfaces impacts the performance of these materials. Optical properties of samples were measured and solar cell performance data was obtained. In general, exposure to contamination by thruster fuel resulted in degradation of solar absorptance for fused silica and various thermal control surfaces and degradation of solar cell performance. Fused silica samples which were subsequently exposed to an atomic oxygen/vacuum ultraviolet radiation environment showed reversal of this degradation. These results imply that solar cells and thermal control surfaces which are susceptible to thruster fuel contamination and which also receive atomic oxygen exposure may not undergo significant performance degradation. Materials which were exposed to only vacuum ultraviolet radiation subsequent to contamination showed slight additional degradation in solar absorptance.

  9. Environmental transformation of 1-nitropyrene on glass surfaces

    International Nuclear Information System (INIS)

    Benson, J.M.; Brooks, A.L.; Cheng, Y.S.; Henderson, T.R.; White, J.E.

    1986-01-01

    Nitro-substituted polycyclic aromatic hydrocarbons are a highly mutagenic class of compounds present in diesel exhaust emissions and in fly ash produced by coal combustion. The photochemistry of nitroaromatic compounds in solution has been the subject of many investigations. The purpose of this study is to provide data to be used to estimate the environmental persistence of nitro-substituted polycyclic aromatic hydrocarbons. The studies reported here focus on the photochemical/chemical transformations of NP as a thin layer of solid material on glass surfaces exposed to natural sunlight. Exposures were for periods from 12 to 670 hours to provide information on the kinetics of transformations. Breakdown products were chemically characterized and evaluated for their mutagenic activities in Salmonella compared to that of unexposed NP

  10. Guidance for establishment and implementation of field sample management programs in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-01-01

    The role of the National Sample Management Program (NSMP) proposed by the Department of Energy's Office of Environmental Management (EM) is to be a resource for EM programs and for local Field Sample Management Programs (FSMPs). It will be a source of information on sample analysis and data collection within the DOE complex. The purpose of this document is to establish the suggested scope of the FSMP activities to be performed under each Operations Office, list the drivers under which the program will operate, define terms and list references. This guidance will apply only to EM sampling and analysis activities associated with project planning, contracting, laboratory selection, sample collection, sample transportation, laboratory analysis and data management

  11. Evaluation of wastewater contaminant transport in surface waters using verified Lagrangian sampling

    Science.gov (United States)

    Antweiler, Ronald C.; Writer, Jeffrey H.; Murphy, Sheila F.

    2014-01-01

    Contaminants released from wastewater treatment plants can persist in surface waters for substantial distances. Much research has gone into evaluating the fate and transport of these contaminants, but this work has often assumed constant flow from wastewater treatment plants. However, effluent discharge commonly varies widely over a 24-hour period, and this variation controls contaminant loading and can profoundly influence interpretations of environmental data. We show that methodologies relying on the normalization of downstream data to conservative elements can give spurious results, and should not be used unless it can be verified that the same parcel of water was sampled. Lagrangian sampling, which in theory samples the same water parcel as it moves downstream (the Lagrangian parcel), links hydrologic and chemical transformation processes so that the in-stream fate of wastewater contaminants can be quantitatively evaluated. However, precise Lagrangian sampling is difficult, and small deviations – such as missing the Lagrangian parcel by less than 1 h – can cause large differences in measured concentrations of all dissolved compounds at downstream sites, leading to erroneous conclusions regarding in-stream processes controlling the fate and transport of wastewater contaminants. Therefore, we have developed a method termed “verified Lagrangian” sampling, which can be used to determine if the Lagrangian parcel was actually sampled, and if it was not, a means for correcting the data to reflect the concentrations which would have been obtained had the Lagrangian parcel been sampled. To apply the method, it is necessary to have concentration data for a number of conservative constituents from the upstream, effluent, and downstream sites, along with upstream and effluent concentrations that are constant over the short-term (typically 2–4 h). These corrections can subsequently be applied to all data, including non-conservative constituents. Finally, we

  12. Evaluation of wastewater contaminant transport in surface waters using verified Lagrangian sampling.

    Science.gov (United States)

    Antweiler, Ronald C; Writer, Jeffrey H; Murphy, Sheila F

    2014-02-01

    Contaminants released from wastewater treatment plants can persist in surface waters for substantial distances. Much research has gone into evaluating the fate and transport of these contaminants, but this work has often assumed constant flow from wastewater treatment plants. However, effluent discharge commonly varies widely over a 24-hour period, and this variation controls contaminant loading and can profoundly influence interpretations of environmental data. We show that methodologies relying on the normalization of downstream data to conservative elements can give spurious results, and should not be used unless it can be verified that the same parcel of water was sampled. Lagrangian sampling, which in theory samples the same water parcel as it moves downstream (the Lagrangian parcel), links hydrologic and chemical transformation processes so that the in-stream fate of wastewater contaminants can be quantitatively evaluated. However, precise Lagrangian sampling is difficult, and small deviations - such as missing the Lagrangian parcel by less than 1h - can cause large differences in measured concentrations of all dissolved compounds at downstream sites, leading to erroneous conclusions regarding in-stream processes controlling the fate and transport of wastewater contaminants. Therefore, we have developed a method termed "verified Lagrangian" sampling, which can be used to determine if the Lagrangian parcel was actually sampled, and if it was not, a means for correcting the data to reflect the concentrations which would have been obtained had the Lagrangian parcel been sampled. To apply the method, it is necessary to have concentration data for a number of conservative constituents from the upstream, effluent, and downstream sites, along with upstream and effluent concentrations that are constant over the short-term (typically 2-4h). These corrections can subsequently be applied to all data, including non-conservative constituents. Finally, we show how data

  13. Computer simulation of RBS spectra from samples with surface roughness

    Czech Academy of Sciences Publication Activity Database

    Malinský, Petr; Hnatowicz, Vladimír; Macková, Anna

    2016-01-01

    Roč. 371, MAR (2016), s. 101-105 ISSN 0168-583X. [22nd International conference on Ion Beam Analysis (IBA). Opatija, 14.06.2015-19.06.2015] R&D Projects: GA MŠk(CZ) LM2011019; GA ČR GA15-01602S Institutional support: RVO:61389005 Keywords : computer simulation * Rutherford backscattering * surface roughness Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.109, year: 2016

  14. o-TOF ICPMS analysis of environmental, food and biological samples

    International Nuclear Information System (INIS)

    Krejcova, A.; Cernohorsky, T.; Ludvikova, I.; Pouzar, M.; Capova, L.

    2009-01-01

    Full text: o-TOF ICPMS was used for inorganic analysis of environmental, food and biological samples. The method validity was proved by analysis of spiked samples, reference materials, by determination without/with internal standards and the standard addition technique. The technique was shown to be powerful, and reliable for analysis of the samples mentioned, and high sample throughput enables environmental or biological screening studies. Independent of the number of elements analyzed, complete analysis and whole mass spectra are gained from a small sample amount in a very short time. (author)

  15. Environmental sampling plan for Kwajalein Atoll Lagoon: 2017 Kwajalein sampling event

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, T. F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-07-01

    Since the early 1980s, the U.S DOE Marshall Islands Program at LLNL has provided radiological monitoring of the marine and terrestrial environment at nuclear affected atolls in the northern Marshall Islands. The fundamental aim of these studies was to identify the level and distribution of key residual fallout radionuclide in the environment, improve understanding of prevalent radiation exposure pathways, and develop predictive dose assessments for resettled and resettling atoll population groups. These data and information were essential in terms of guiding the development of effective and environmentally protective remedial measures, and promoting potential actions to improve on food safety and security.

  16. An overview of sample preparation procedures for LC-MS multiclass antibiotic determination in environmental and food samples.

    Science.gov (United States)

    Moreno-Bondi, María Cruz; Marazuela, María Dolores; Herranz, Sonia; Rodriguez, Erika

    2009-10-01

    Antibiotics are a class of pharmaceuticals that are of great interest due to the large volumes of these substances that are consumed in both human and veterinary medicine, and due to their status as the agents responsible for bacterial resistance. They can be present in foodstuffs and in environmental samples as multicomponent chemical mixtures that exhibit a wide range of mechanisms of action. Moreover, they can be transformed into different metabolites by the action of microorganisms, as well as by other physical or chemical means, resulting in mixtures with higher ecotoxicities and risks to human health than those of the individual compounds. Therefore, there is growing interest in the availability of multiclass methods for the analysis of antimicrobial mixtures in environmental and food samples at very low concentrations. Liquid chromatography (LC) has become the technique of choice for multiclass analysis, especially when coupled to mass spectrometry (LC-MS) and tandem MS (LC-MS(2)). However, due to the complexity of the matrix, in most cases an extraction step for sample clean-up and preconcentration is required before analysis in order to achieve the required sensitivities. This paper reviews the most recent developments and applications of multiclass antimicrobial determination in environmental and food matrices, emphasizing the practical aspects of sample preparation for the simultaneous extraction of antimicrobials from the selected samples. Future trends in the application of LC-MS-based techniques to multiclass antibiotic analysis are also presented.

  17. Biodecontamination of concrete surfaces: Occupational and environmental benefits

    International Nuclear Information System (INIS)

    Johnson, L.; Rogers, R.; Hamilton, M.; Nelson, L.

    1996-01-01

    Managers and engineers around the globe are presently challenged by high estimated costs for the decontamination and decommissioning of nuclear facilities which are no longer needed or are abandoned. It has been estimated that more than 73 Km 2 of contaminated concrete currently exists in the USDOE complex and is increased many fold when similar facilities are accounted for in other countries. Needs for the decontamination of concrete have been identified as: more cost effective decontamination methods, reduction of secondary wastes, minimized worker radiation exposures and, contaminant containment. Recently environmental microbes have been harnessed to remove the surface of concrete as a technique for decontamination and decommissioning (D and D). This biodecontamination technology has been tested by INEL and BNFL scientists and engineers in both US and United Kingdom nuclear facilities. Biodecontamination field tests at a shutdown nuclear reactor facility (EBR-I) have shown radioactively contaminated surface removed at rates of 4--8 mm/yr, thus validating the feasibility of this technology. Engineering economic analyses indicate two attractive benefits embedded in this approach to concrete D and D: (1) due to the passive nature of the technique, a cost savings of more than an order of magnitude is projected compared to the current labor intensive physical decontamination techniques; and (2) the exposure to humans and the natural environment is greatly reduced due to the unattended, highly contained biodecontamination process

  18. Identification and assay of radionuclides in the environmental samples following Chernobyl reactor accident

    International Nuclear Information System (INIS)

    Prakash, S.

    1987-01-01

    In India radioactivity was detected from 2 May 1986 onwards. A variety of samples were assayed for radionuclides in the environmental samples originating from the Chernobyl reactor accident. These are: Cotton swipe samples from aircrafts, air filters, milk, goat thyroids, grass, vegetables and tap waters. The results are presented in the paper

  19. Fast Characterization of Moving Samples with Nano-Textured Surfaces

    DEFF Research Database (Denmark)

    Madsen, Morten Hannibal; Hansen, Poul-Erik; Zalkovskij, Maksim

    2015-01-01

    Characterization of structures using conventional optical microscopy is restricted by the diffraction limit. Techniques like atomic force and scanning electron microscopy can investigate smaller structures but are very time consuming. We show that using scatterometry, a technique based on optical...... diffraction, integrated into a commercial light microscope we can characterize nano-textured surfaces in a few milliseconds. The adapted microscope has two detectors, a CCD camera used to easily find an area of interest and a spectrometer for the measurements. We demonstrate that the microscope has...

  20. Isotope dilution and sampling factors of the quality assurance and TQM of environmental analysis

    International Nuclear Information System (INIS)

    Macasek, F.

    1999-01-01

    Sampling and preparatory treatment of environmental objects is discussed from the view of their information content, functional speciation of the pollutant, statistical distribution treatment and uncertainty assessment. During homogenization of large samples, a substantial information may be lost and validity of environmental information becomes vague. Isotope dilution analysis is discussed as the most valuable tool for both validity of analysis and evaluation of samples variance. Data collection for a non-parametric statistical treatment of series of 'non-representative' sub-samples, and physico-chemical speciation of analyte may actually better fulfill criteria of similarity and representativeness. Large samples are often required due to detection limits of analysis, but the representativeness of environmental samples should by understood not only by the mean analyte concentration, but also by its spatial and time variance. Hence, heuristic analytical scenarios and interpretation of results must be designed by cooperation of environmentalists and analytical chemists. (author)

  1. Qualitative and quantitative analysis of environmental samples by laser-induced breakdown spectrometry

    International Nuclear Information System (INIS)

    Zorov, N B; Popov, A M; Zaytsev, S M; Labutin, T A

    2015-01-01

    The key achievements in the determination of trace amounts of components in environmental samples (soils, ores, natural waters, etc.) by laser-induced breakdown spectrometry are considered. Unique capabilities of this method make it suitable for rapid analysis of metals and alloys, glasses, polymers, objects of cultural heritage, archaeological and various environmental samples. The key advantages of the method that account for its high efficiency are demonstrated, in particular, a small amount of analyzed material, the absence of sample preparation, the possibility of local and remote analysis of either one or several elements. The use of chemometrics in laser-induced breakdown spectrometry for qualitative sample classification is described in detail. Various approaches to improving the figures of merit of quantitative analysis of environmental samples are discussed. The achieved limits of detection for most elements in geochemical samples are critically evaluated. The bibliography includes 302 references

  2. Method validation and uncertainty evaluation of organically bound tritium analysis in environmental sample.

    Science.gov (United States)

    Huang, Yan-Jun; Zeng, Fan; Zhang, Bing; Chen, Chao-Feng; Qin, Hong-Juan; Wu, Lian-Sheng; Guo, Gui-Yin; Yang, Li-Tao; Shang-Guan, Zhi-Hong

    2014-08-01

    The analytical method for organically bound tritium (OBT) was developed in our laboratory. The optimized operating conditions and parameters were established for sample drying, special combustion, distillation, and measurement on a liquid scintillation spectrometer (LSC). Selected types of OBT samples such as rice, corn, rapeseed, fresh lettuce and pork were analyzed for method validation of recovery rate reproducibility, the minimum detection concentration, and the uncertainty for typical low level environmental sample was evaluated. The combustion water recovery rate of different dried environmental sample was kept at about 80%, the minimum detection concentration of OBT ranged from 0.61 to 0.89 Bq/kg (dry weight), depending on the hydrogen content. It showed that this method is suitable for OBT analysis of environmental sample with stable recovery rate, and the combustion water yield of a sample with weight about 40 g would provide sufficient quantity for measurement on LSC. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Determination of natural alpha-emitting isotopes of uranium and thorium in environmental and geological samples

    International Nuclear Information System (INIS)

    Crespo, M.T.

    1996-01-01

    It is described the complete radiochemical procedure used for the determination of uranium and thorium isotopes in environmental and geological samples by alpha spectrometry. Source preparation methods, alpha-counting and spectral analysis are also included

  4. Engineering Task Plan to Expand the Environmental Operational Envelope of Core Sampling

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    This Engineering Task Plan authorizes the development of an Alternative Generation and Analysis (AGA). The AGA will determine how to expand the environmental operating envelope during core sampling operations

  5. Microbial environmental contamination in Italian dental clinics: A multicenter study yielding recommendations for standardized sampling methods and threshold values.

    Science.gov (United States)

    Pasquarella, Cesira; Veronesi, Licia; Napoli, Christian; Castiglia, Paolo; Liguori, Giorgio; Rizzetto, Rolando; Torre, Ida; Righi, Elena; Farruggia, Patrizia; Tesauro, Marina; Torregrossa, Maria V; Montagna, Maria T; Colucci, Maria E; Gallè, Francesca; Masia, Maria D; Strohmenger, Laura; Bergomi, Margherita; Tinteri, Carola; Panico, Manuela; Pennino, Francesca; Cannova, Lucia; Tanzi, Marialuisa

    2012-03-15

    A microbiological environmental investigation was carried out in ten dental clinics in Italy. Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days, for one week per month, for a three-month period. Water and surfaces were sampled before and after clinical activity; air was sampled before, after, and during clinical activity. A wide variation was found in microbial environmental contamination, both within the participating clinics and for the different sampling times. Before clinical activity, microbial water contamination in tap water reached 51,200cfu/mL (colony forming units per milliliter), and that in Dental Unit Water Systems (DUWSs) reached 872,000cfu/mL. After clinical activity, there was a significant decrease in the Total Viable Count (TVC) in tap water and in DUWSs. Pseudomonas aeruginosa was found in 2.38% (7/294) of tap water samples and in 20.06% (59/294) of DUWS samples; Legionella spp. was found in 29.96% (89/297) of tap water samples and 15.82% (47/297) of DUWS samples, with no significant difference between pre- and post-clinical activity. Microbial air contamination was highest during dental treatments, and decreased significantly at the end of the working activity (p<0.05). The microbial buildup on surfaces increased significantly during the working hours. This study provides data for the establishment of standardized sampling methods, and threshold values for contamination monitoring in dentistry. Some very critical situations have been observed which require urgent intervention. Furthermore, the study emphasizes the need for research aimed at defining effective managing strategies for dental clinics. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Alternative to chrome in the aluminium surface finishing industry. Low environmental impact surface treatments

    International Nuclear Information System (INIS)

    Aballe Villero, A.; Bethencourt Nunez, M.; Botana Pedemonte, F. J.; Marco Barcena, M.; Sanchez-Amaya, J. M.

    2001-01-01

    Chromates are one of the most commonly used compounds in anti corrosive protection systems because of its excellent rate efficiency/cost. In the case of aluminium alloys, these compounds are employed as inhibitors as well as in the anti-corrosive pretreatments to develop protective films. However, chromates are highly toxic and its use involves a high risk for health and environment. Consequently, in the last years intensive efforts have been achieved in the surface treatment industry to find ecological alternatives to this kind of compounds. In this work, the main alternatives proposed in literature to substitute chromates in the surface treatments of aluminium alloys are reviewed. To begin with, the role of chromates in these systems and their environmental consequences has been briefly reviewed. (Author) 16 refs

  7. A review of analytical techniques for the determination of carbon-14 in environmental samples

    International Nuclear Information System (INIS)

    Milton, G.M.; Brown, R.M.

    1993-11-01

    This report contains a brief summary of analytical techniques commonly used for the determination of radiocarbon in a variety of environmental samples. Details of the applicable procedures developed and tested in the Environmental Research Branch at Chalk River Laboratories are appended

  8. Utilizing Raman Spectroscopy and Surface-Enhanced Raman Spectroscopy to investigate healthy and cancerous colon samples

    International Nuclear Information System (INIS)

    Barzegar, A.; Rezaei, H.; Malekfar, R.

    2012-01-01

    In this study, spontaneous Raman scattering and surface-enhanced Raman scattering, Surface-Enhanced Raman Spectroscopy spectra have been investigated. The samples which were kept in the formalin solution selected from the human's healthy and cancerous colon tissues. The Surface-Enhanced Raman Spectroscopy spectra were collected by adding colloidal solution contained silver nanoparticles to the top of the samples. The recorded spectra were compared for the spontaneous Raman spectra of healthy and cancerous colon samples. The spontaneous and surface enhanced Raman scattering data were also collected and compared for both healthy and damaged samples.

  9. Hydroxylated PCBs in abiotic environmental matrices. Precipitation and surface waters

    Energy Technology Data Exchange (ETDEWEB)

    Darling, C.; Alaee, M.; Campbell, L.; Pacepavicius, G.; Ueno, D.; Muir, D. [National Water Research Institute, Burlington, ON (Canada)

    2004-09-15

    Hydroxylated PCBs (OH-PCBs) are of great interest environmentally because of their potential thyroidogenic effects. OH-PCBs can compete with thyroxine for binding sites on transthyretin, one of the three main thyroid hormone transport proteins in mammals1. The chemical structures of some OH-PCBs with a para OH group and adjacent chlorine atoms, particularly 4-OH-CB109, 4- OH-CB146, and 4-OH-CB187, share a similar structure to the thyroid hormones (T3 and T4), which have a para OH with adjacent iodine atoms. A number of OH-PCBs have been identified in the blood of humans and biota during the last 5 to 10 years, however, reports on the identity, presence and levels of OH-PCBs are limited. This presentation describes preliminary studies on the presence of OH-PCBs in abiotic samples and comparisons of congener patterns with biological samples. We have previously shown that OHPCBs were present in lake trout from the Great Lakes and nearby large lakes as well as in nearshore environments. We hypothesized that some of the OH-PCB present in fish might be from abiotic formation in water or the atmosphere, or from microbial oxidation of PCBs and/or deconjugation of PCB metabolites in waste treatment plants.

  10. Green Aspects of Techniques for the Determination of Currently Used Pesticides in Environmental Samples

    OpenAIRE

    Maciej Tankiewicz; Jacek Namieśnik; Jolanta Stocka; Marek Biziuk

    2011-01-01

    Pesticides are among the most dangerous environmental pollutants because of their stability, mobility and long-term effects on living organisms. Their presence in the environment is a particular danger. It is therefore crucial to monitor pesticide residues using all available analytical methods. The analysis of environmental samples for the presence of pesticides is very difficult: the processes involved in sample preparation are labor-intensive and time-consuming. To date, it has been standa...

  11. Speciation of organotin compounds in environmental samples by GC-ICPMS

    International Nuclear Information System (INIS)

    Vahcic, M.; Milacic, R.; Scancar, J.

    2009-01-01

    Full text: Analytical procedure using 15 m GC column was applied for simultaneous speciation of OTCs in various environmental samples. Methyl-, butyl-, phenyl- and octyl- tin species were quantitatively determined. different extraction reagents and conditions were studied. OTCs species were derivatized by NaBEt 4 and extracted into isooctane or hexane. The applied analytical procedure considerably shortened analytical time and enabled simultaneous determination of 12 OTCs in environmental samples. (author)

  12. Evaluation of Brazilian intercomparison program data from 1991 to 1995 of radionuclide assays in environmental samples

    International Nuclear Information System (INIS)

    Vianna, Maria Elizabeth Couto M.; Tauhata, Luiz; Oliveira, Antonio Eduardo de; Oliveira, Josue Peter de; Clain, Almir Faria; Ferreira, Ana Cristina M.

    1998-01-01

    Historical radioanalytical data from the Institute of Radiation Protection and Dosimetry (IRD) national intercomparison program from 1991 to 1995 were analyzed to evaluate the performance of sixteen Brazilian laboratories in radionuclide analyses in environmental samples. Data are comprised of measurements of radionuclides in 435 spiked environmental samples distributed in fifteen intercomparison runs comprised of 955 analyses. The general and specific radionuclide performances of the participating laboratories were evaluated relative to the reference value. Data analysis encourages improvements in beta emitter measurements

  13. Sampling and sample handling procedures for priority pollutants in surface coal mining wastewaters. [Detailed list to be analyzed for

    Energy Technology Data Exchange (ETDEWEB)

    Hayden, R. S.; Johnson, D. O.; Henricks, J. D.

    1979-03-01

    The report describes the procedures used by Argonne National Laboratory to sample surface coal mine effluents in order to obtain field and laboratory data on 110 organic compounds or classes of compounds and 14 metals and minerals that are known as priority pollutants, plus 5-day biochemical oxygen demand (BOD/sub 5/), total organic carbon (TOC), chemical oxygen demand (COD), total dissolved solids (TDS), and total suspended solids (TSS). Included are directions for preparation of sampling containers and equipment, methods of sampling and sample preservation, and field and laboratory protocols, including chain-of-custody procedures. Actual analytical procedures are not described, but their sources are referenced.

  14. Joint sampling programme-Verification of data obtained in environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lauria, D.C. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/no., CEP 22780-160, Rio de Janeiro, RJ (Brazil)], E-mail: dejanira@ird.gov.br; Martins, N.S.F.; Vasconcellos, M.L.H.; Zenaro, R.; Peres, S.S.; Pires do Rio, M.A. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/no., CEP 22780-160, Rio de Janeiro, RJ (Brazil)

    2008-11-15

    The objective of the Environmental Radiological Monitoring Control programme carried out by the Institute of Radiation Protection and Dosimetry (IRD) in Brazil is to verify the licensee's compliance with the requirements for environmental monitoring of Brazilian facilities. The Joint Sampling Programme (JSP) is just one part of the control programme. In order to verify that the data reported by the licensees is representative and legitimate, this programme verifies sampling procedures, accuracy and precision of the data and the changes in the environmental conditions. This paper discusses the main findings of this programme that allowed IRD to optimize its available resources to control the monitoring of the eight facilities in Brazil.

  15. Empirical insights and considerations for the OBT inter-laboratory comparison of environmental samples

    International Nuclear Information System (INIS)

    Kim, Sang-Bog; Roche, Jennifer

    2013-01-01

    Organically bound tritium (OBT) is an important tritium species that can be measured in most environmental samples, but has only recently been recognized as a species of tritium in these samples. Currently, OBT is not routinely measured by environmental monitoring laboratories around the world. There are no certified reference materials (CRMs) for environmental samples. Thus, quality assurance (QA), or verification of the accuracy of the OBT measurement, is not possible. Alternatively, quality control (QC), or verification of the precision of the OBT measurement, can be achieved. In the past, there have been differences in OBT analysis results between environmental laboratories. A possible reason for the discrepancies may be differences in analytical methods. Therefore, inter-laboratory OBT comparisons among the environmental laboratories are important and would provide a good opportunity for adopting a reference OBT analytical procedure. Due to the analytical issues, only limited information is available on OBT measurement. Previously conducted OBT inter-laboratory practices are reviewed and the findings are described. Based on our experiences, a few considerations were suggested for the international OBT inter-laboratory comparison exercise to be completed in the near future. -- Highlights: ► Inter-laboratory OBT comparisons would provide a good opportunity for developing reference OBT analytical procedures. ► The measurement of environmental OBT concentrations has a higher associated uncertainty. ► Certified reference materials for OBT in environmental samples are required

  16. A new sampling technique for surface exposure dating using a portable electric rock cutter

    Directory of Open Access Journals (Sweden)

    Yusuke Suganuma

    2012-07-01

    Full Text Available Surface exposure dating using in situ cosmogenic nuclides has contributed to our understanding of Earth-surface processes. The precision of the ages estimated by this method is affected by the sample geometry; therefore, high accuracy measurements of the thickness and shape of the rock sample (thickness and shape is crucial. However, it is sometimes diffi cult to meet these requirements by conventional sampling methods with a hammer and chisel. Here, we propose a new sampling technique using a portable electric rock cutter. This sampling technique is faster, produces more precisely shaped samples, and allows for a more precise age interpretation. A simple theoretical modeldemonstrates that the age error due to defective sample geometry increases as the total sample thickness increases, indicating the importance of precise sampling for surface exposure dating.

  17. Tritium concentrations in environmental water and food samples collected around the vicinity of the PNPP-1

    International Nuclear Information System (INIS)

    Garcia, T.Y.; Enriquez, S.O.; Duran, E.B.

    1986-01-01

    The natural radioactivity levels of tritium in environmental samples collected around the vicinity and more distant environment of the first Philippine Nuclear Power Plant (PNPP-1) in Bataan were assessed. The samples analyzed consisted of water samples such as seawater, freshwater, drinking water, groundwater and rainwater; and food samples such as cereals, vegetables, fruits; meat, milk fish and crustaceans. Tritium concentrations in water samples were determined by distillation and liquid scintillation counting techniques. The food samples were analyzed for tissue-free water tritium by the freezing-drying method followed by liquid scintillation counting techniques. (Auth.) 13 refs

  18. Studies on 129I and 14C in environmental samples by AMS

    International Nuclear Information System (INIS)

    Muramatsu, Yasuyuki

    2010-01-01

    We have carried out studies on 129 I and 14 C in environmental samples by AMS (accelerator mass spectrometry). In this paper summary of our results are described. Iodine is an essential element for humans and it pays an important role in thyroid gland. There are more than 30 isotopes of iodine. Among radioiodines 129 I has the longest half-life (1.57x10 7 y). This nuclide is released into the environment from nuclear weapons test, accidents of nuclear facilities (e.g. Chernobyl accident) and operation of spent fuel reprocessing plants. Since soil accumulates iodine, we have focused on the levels of both 129 I and 127 I in surface soils. In our previous studies, we used NAA (neutron activation analysis) for the determination. However, due to the limitation of its analytical sensitivity we could not detect 129 I in samples from background areas. In this study we have analyzed 129 I/ 127 I ratios by AMS and 127 I concentrations by ICP-MS (inductively coupled plasma spectrometry) after separation of iodine from soil by pyrohydrolysis and solvent extraction techniques. Using these methods, we have analyzed samples collected from different areas in Japan. Analytical results for surface soils collected from background areas were in the ranges 1.4 x 10 -5 - 4.6 x 10 -3 Bq/Kg as 129 I concentrations and 3.9 x 10 -11 - 3.0 x 10 -8 as 129 I/ 127 I ratios. The 129 I levels in Tokaimura, where a spent fuel reprocessing plant is located, were one to three orders of magnitude higher than those in background samples. The levels were higher in forest soils than those in field and rice paddy soils due to the interception effect of atmospheric 129 I by tree canopies. A wide range of stable iodine concentrations (0.4-143ppm) was observed. Rice paddy soils contained significantly lower iodine than forest and upland field soils. This should be explained by the desorption of iodine from the rice paddies due to microbial activities during the cultivation. Vertical distributions of 129 I

  19. Comparing rapid methods for detecting Listeria in seafood and environmental samples using the most probably number (MPN) technique.

    Science.gov (United States)

    Cruz, Cristina D; Win, Jessicah K; Chantarachoti, Jiraporn; Mutukumira, Anthony N; Fletcher, Graham C

    2012-02-15

    The standard Bacteriological Analytical Manual (BAM) protocol for detecting Listeria in food and on environmental surfaces takes about 96 h. Some studies indicate that rapid methods, which produce results within 48 h, may be as sensitive and accurate as the culture protocol. As they only give presence/absence results, it can be difficult to compare the accuracy of results generated. We used the Most Probable Number (MPN) technique to evaluate the performance and detection limits of six rapid kits for detecting Listeria in seafood and on an environmental surface compared with the standard protocol. Three seafood products and an environmental surface were inoculated with similar known cell concentrations of Listeria and analyzed according to the manufacturers' instructions. The MPN was estimated using the MPN-BAM spreadsheet. For the seafood products no differences were observed among the rapid kits and efficiency was similar to the BAM method. On the environmental surface the BAM protocol had a higher recovery rate (sensitivity) than any of the rapid kits tested. Clearview™, Reveal®, TECRA® and VIDAS® LDUO detected the cells but only at high concentrations (>10(2) CFU/10 cm(2)). Two kits (VIP™ and Petrifilm™) failed to detect 10(4) CFU/10 cm(2). The MPN method was a useful tool for comparing the results generated by these presence/absence test kits. There remains a need to develop a rapid and sensitive method for detecting Listeria in environmental samples that performs as well as the BAM protocol, since none of the rapid tests used in this study achieved a satisfactory result. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Rapid filtration separation-based sample preparation method for Bacillus spores in powdery and environmental matrices.

    Science.gov (United States)

    Isabel, Sandra; Boissinot, Maurice; Charlebois, Isabelle; Fauvel, Chantal M; Shi, Lu-E; Lévesque, Julie-Christine; Paquin, Amélie T; Bastien, Martine; Stewart, Gale; Leblanc, Eric; Sato, Sachiko; Bergeron, Michel G

    2012-03-01

    Authorities frequently need to analyze suspicious powders and other samples for biothreat agents in order to assess environmental safety. Numerous nucleic acid detection technologies have been developed to detect and identify biowarfare agents in a timely fashion. The extraction of microbial nucleic acids from a wide variety of powdery and environmental samples to obtain a quality level adequate for these technologies still remains a technical challenge. We aimed to develop a rapid and versatile method of separating bacteria from these samples and then extracting their microbial DNA. Bacillus atrophaeus subsp. globigii was used as a simulant of Bacillus anthracis. We studied the effects of a broad variety of powdery and environmental samples on PCR detection and the steps required to alleviate their interference. With a benchmark DNA extraction procedure, 17 of the 23 samples investigated interfered with bacterial lysis and/or PCR-based detection. Therefore, we developed the dual-filter method for applied recovery of microbial particles from environmental and powdery samples (DARE). The DARE procedure allows the separation of bacteria from contaminating matrices that interfere with PCR detection. This procedure required only 2 min, while the DNA extraction process lasted 7 min, for a total of sample preparation procedure allowed the recovery of cleaned bacterial spores and relieved detection interference caused by a wide variety of samples. Our procedure was easily completed in a laboratory facility and is amenable to field application and automation.

  1. Report for Detection of Biothreat Agents and Environmental Samples using the LLNL Virulence Array for DHS

    Energy Technology Data Exchange (ETDEWEB)

    Jaing, Crystal [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Gardner, Shea [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); McLoughlin, Kevin [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Thissen, James [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Jackson, Paul [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2011-04-18

    The objective of this project is to provide DHS a comprehensive evaluation of the current genomic technologies including genotyping, Taqman PCR, multiple locus variable tandem repeat analysis (MLVA), microarray and high-throughput DNA sequencing in the analysis of biothreat agents from complex environmental samples. This report focuses on the design, testing and results of samples on the Virulence Array.

  2. Demonstration and determination of submicroscopic particles of uranium in environmental samples

    International Nuclear Information System (INIS)

    Sihelska, K.; Lorincik, J.; Sus, F.; Vesela, D.

    2016-01-01

    In this work laboratories of the Centrum vyzkumu Rez, Ltd are presented. Fission track analysis (FTA) is used for analysis of uranium in environmental samples. Treatment of samples for FTA is described and some results ar presented. The method of SIMS is used, too.

  3. Rapid instrumental and separation methods for monitoring radionuclides in food and environmental samples. Progress report

    International Nuclear Information System (INIS)

    Bhat, I.S.; Shukla, V.K.; Singh, A.N.; Nair, C.K.G.; Hingorani, S.B.; Dey, N.N.; Jha, S.K.; Rao, D.D.

    1995-01-01

    surface barrier detector, in close agreement. Presently the liquid scintillation counter is used with discriminator settling adjusted to count Pu alpha pulses and also the output from the liquid scintillator is connected to a 2K MCA to see the alpha spectrum. The unit at present does not have the Pulse Shape Analyser (PSA) unit which is being planned to be incorporated in the system to improve the resolution. The work is in progress for direct extraction to a liquid scintillation cocktail containing extracting reagents like high mol. amine (TIOA) and Di2 ethyl hexyl phosphoric acid and then count by liquid scintillation counting. Solvent extraction using specific reagent and then direct liquid scintillation counting is being investigated as a general rapid method for beta and alpha emitters in environmental samples

  4. Least-squares resolution of gamma-ray spectra in environmental samples

    International Nuclear Information System (INIS)

    Kanipe, L.G.; Seale, S.K.; Liggett, W.S.

    1977-08-01

    The use of ALPHA-M, a least squares computer program for analyzing NaI (Tl) gamma spectra of environmental samples, is evaluated. Included is a comprehensive set of program instructions, listings, and flowcharts. Two other programs, GEN4 and SIMSPEC, are also described. GEN4 is used to create standard libraries for ALPHA-M, and SIMSPEC is used to simulate spectra for ALPHA-M analysis. Tests to evaluate the standard libraries selected for use in analyzing environmental samples are provided. An evaluation of the results of sample analyses is discussed

  5. Evaluation of environmental sampling methods for detection of Salmonella enterica in a large animal veterinary hospital.

    Science.gov (United States)

    Goeman, Valerie R; Tinkler, Stacy H; Hammac, G Kenitra; Ruple, Audrey

    2018-04-01

    Environmental surveillance for Salmonella enterica can be used for early detection of contamination; thus routine sampling is an integral component of infection control programs in hospital environments. At the Purdue University Veterinary Teaching Hospital (PUVTH), the technique regularly employed in the large animal hospital for sample collection uses sterile gauze sponges for environmental sampling, which has proven labor-intensive and time-consuming. Alternative sampling methods use Swiffer brand electrostatic wipes for environmental sample collection, which are reportedly effective and efficient. It was hypothesized that use of Swiffer wipes for sample collection would be more efficient and less costly than the use of gauze sponges. A head-to-head comparison between the 2 sampling methods was conducted in the PUVTH large animal hospital and relative agreement, cost-effectiveness, and sampling efficiency were compared. There was fair agreement in culture results between the 2 sampling methods, but Swiffer wipes required less time and less physical effort to collect samples and were more cost-effective.

  6. Detection and Molecular Characterization of Gemycircularvirus from Environmental Samples in Brazil.

    Science.gov (United States)

    da Silva Assis, Matheus Ribeiro; Vieira, Carmen Baur; Fioretti, Julia Monassa; Rocha, Mônica Simões; de Almeida, Pedro Ivo Neves; Miagostovich, Marize Pereira; Fumian, Tulio Machado

    2016-12-01

    Gemycircularvirus (GemyCV) is a group of viruses which has been recently proposed as a new viral genus detected in fecal and environmental samples around the world. GemyCVs have been detected in human blood, brain tissue, cerebrospinal fluid, and stool sample. In the present study, we demonstrate for the first time, through molecular detection and characterization, the presence of GemyCVs in environmental samples from Brazil. Our results show a percentage of positivity ranging from 69 (25/36) to 97 % (35/36) in river water samples collected in Manaus, Amazon region, and wastewater from a wastewater treatment plant located in Rio de Janeiro, respectively, revealing GemyCVs as an important environmental contaminant.

  7. Lessons learned from surface wipe sampling for lead in three workplaces.

    Science.gov (United States)

    Beaucham, Catherine; Ceballos, Diana; King, Bradley

    2017-08-01

    Surface wipe sampling in the occupational environment is a technique widely used by industrial hygienists. Although several organizations have promulgated standards for sampling lead and other metals, uncertainty still exists when trying to determine an appropriate wipe sampling strategy and how to interpret sampling results. Investigators from the National Institute for Occupational Safety and Health (NIOSH) Health Hazard Evaluation Program have used surface wipe sampling as part of their exposure assessment sampling strategies in a wide range of workplaces. This article discusses wipe sampling for measuring lead on surfaces in three facilities: (1) a battery recycling facility; (2) a firing range and gun store; and (3) an electronic scrap recycling facility. We summarize our findings from the facilities and what we learned by integrating wipe sampling into our sampling plan. Wiping sampling demonstrated lead in non-production surfaces in all three workplaces and that the potential that employees were taking lead home to their families existed. We also found that the presence of metals such as tin can interfere with the colorimetric results. We also discuss the advantages and disadvantages of colorimetric analysis of surface wipe samples and the challenges we faced when interpreting wipe sampling results.

  8. July 2011 Memorandum: Improving EPA Review of Appalachian Surface Coal Mining Operations Under the Clean Water Act, National Environmental Policy Act, and the Environmental Justice Executive Order

    Science.gov (United States)

    Memorandum: Improving EPA Review of Appalachian Surface Coal Mining Operations Under the Clean Water Act, National Environmental Policy Act, and the Environmental Justice Executive Order, July 21, 2011

  9. Radiochemical separation of actinides for their determination in environmental samples and waste products

    Energy Technology Data Exchange (ETDEWEB)

    Gleisberg, B [Nuclear Engineering and Analytics Rossendorf, Inc. (VKTA), Dresden (Germany)

    1997-03-01

    The determination of low level activities of actinides in environmental samples and waste products makes high demands on radiochemical separation methods. Artificial and natural actinides were analyzed in samples form the surrounding areas of NPP and of uranium mines, incorporation samples, solutions containing radioactive fuel, solutions and solids resutling from the process, and in wastes. The activities are measured by {alpha}-spectrometry and {gamma}-spectrometry. (DG)

  10. Multielement fingerprinting for characterization: Earthworm samples from the environmental specimen bank of the FRG

    International Nuclear Information System (INIS)

    Rossbach, M.; Stoeppler, M.

    1988-01-01

    Earthworm samples (Lumbricidae) from three different sampling sites in the Federal Republic of Germany were collected for the German Environmental Specimen Bank (ESB). Subsamples of the cryohomogenized material from two annual samplings were analyzed by Instrumental Neutron Activation Analysis (INAA) and mean values are presented in the logarithmic fingerprint mode. The 'identical matrix reference material concept' of the ESB has been applied and proved to be of particular value for multielement determinations. (orig.)

  11. Improvements to sample processing and measurement to enable more widespread environmental application of tritium

    Energy Technology Data Exchange (ETDEWEB)

    Moran, James; Alexander, Thomas; Aalseth, Craig; Back, Henning; Mace, Emily; Overman, Cory; Seifert, Allen; Freeburg, Wilcox

    2017-08-01

    Previous measurements have demonstrated the wealth of information that tritium (T) can provide on environmentally relevant processes. We present modifications to sample preparation approaches that enable T measurement by proportional counting on small sample sizes equivalent to 120 mg of water and demonstrate the accuracy of these methods on a suite of standardized water samples. This enhanced method should provide the analytical flexibility needed to address persistent knowledge gaps in our understanding of T behavior in the environment.

  12. Nontuberculous Mycobacteria Isolation from Clinical and Environmental Samples in Iran: Twenty Years of Surveillance

    Directory of Open Access Journals (Sweden)

    Ali Akbar Velayati

    2015-01-01

    Full Text Available Nontuberculous mycobacteria (NTM are opportunistic pathogens that are widely distributed in the environment. There is a lack of data on species distribution of these organisms from Iran. This study consists of a review of NTM articles published in Iran between the years 1992 and 2014. In this review, 20 articles and 14 case reports were identified. Among the 20 articles, 13 (65% studies focused on NTM isolates from clinical specimens, 6 (30% studies examined NTM isolates from environmental samples, and one (5% article included both clinical and environmental isolates. M. fortuitum (229/997; 23% was recorded as the most prevalent and rapid growing mycobacteria (RGM species in both clinical (28% and environmental (19% isolated samples (P < 0.05. Among slow growing mycobacteria (SGM, M. simiae (103/494; 21% demonstrated a higher frequency in clinical samples whereas in environmental samples it was M. flavescens (44/503; 9%. These data represent information from 14 provinces out of 31 provinces of Iran. No information is available in current published data on clinical or environmental NTM from the remaining 17 provinces in Iran. These results emphasize the potential importance of NTM as well as the underestimation of NTM frequency in Iran. NTM is an important clinical problem associated with significant morbidity and mortality in Iran. Continued research is needed from both clinical and environmental sources to help clinicians and researchers better understand and address NTM treatment and prevention.

  13. Nontuberculous Mycobacteria Isolation from Clinical and Environmental Samples in Iran: Twenty Years of Surveillance.

    Science.gov (United States)

    Velayati, Ali Akbar; Farnia, Parissa; Mozafari, Mohadese; Mirsaeidi, Mehdi

    2015-01-01

    Nontuberculous mycobacteria (NTM) are opportunistic pathogens that are widely distributed in the environment. There is a lack of data on species distribution of these organisms from Iran. This study consists of a review of NTM articles published in Iran between the years 1992 and 2014. In this review, 20 articles and 14 case reports were identified. Among the 20 articles, 13 (65%) studies focused on NTM isolates from clinical specimens, 6 (30%) studies examined NTM isolates from environmental samples, and one (5%) article included both clinical and environmental isolates. M. fortuitum (229/997; 23%) was recorded as the most prevalent and rapid growing mycobacteria (RGM) species in both clinical (28%) and environmental (19%) isolated samples (P < 0.05). Among slow growing mycobacteria (SGM), M. simiae (103/494; 21%) demonstrated a higher frequency in clinical samples whereas in environmental samples it was M. flavescens (44/503; 9%). These data represent information from 14 provinces out of 31 provinces of Iran. No information is available in current published data on clinical or environmental NTM from the remaining 17 provinces in Iran. These results emphasize the potential importance of NTM as well as the underestimation of NTM frequency in Iran. NTM is an important clinical problem associated with significant morbidity and mortality in Iran. Continued research is needed from both clinical and environmental sources to help clinicians and researchers better understand and address NTM treatment and prevention.

  14. State of the art of environmentally friendly sample preparation approaches for determination of PBDEs and metabolites in environmental and biological samples: A critical review.

    Science.gov (United States)

    Berton, Paula; Lana, Nerina B; Ríos, Juan M; García-Reyes, Juan F; Altamirano, Jorgelina C

    2016-01-28

    Green chemistry principles for developing methodologies have gained attention in analytical chemistry in recent decades. A growing number of analytical techniques have been proposed for determination of organic persistent pollutants in environmental and biological samples. In this light, the current review aims to present state-of-the-art sample preparation approaches based on green analytical principles proposed for the determination of polybrominated diphenyl ethers (PBDEs) and metabolites (OH-PBDEs and MeO-PBDEs) in environmental and biological samples. Approaches to lower the solvent consumption and accelerate the extraction, such as pressurized liquid extraction, microwave-assisted extraction, and ultrasound-assisted extraction, are discussed in this review. Special attention is paid to miniaturized sample preparation methodologies and strategies proposed to reduce organic solvent consumption. Additionally, extraction techniques based on alternative solvents (surfactants, supercritical fluids, or ionic liquids) are also commented in this work, even though these are scarcely used for determination of PBDEs. In addition to liquid-based extraction techniques, solid-based analytical techniques are also addressed. The development of greener, faster and simpler sample preparation approaches has increased in recent years (2003-2013). Among green extraction techniques, those based on the liquid phase predominate over those based on the solid phase (71% vs. 29%, respectively). For solid samples, solvent assisted extraction techniques are preferred for leaching of PBDEs, and liquid phase microextraction techniques are mostly used for liquid samples. Likewise, green characteristics of the instrumental analysis used after the extraction and clean-up steps are briefly discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Hanford Environmental Information System (HEIS). Volume 7: Sample and Data Tracking subject area

    International Nuclear Information System (INIS)

    1994-06-01

    The Hanford Environmental Information System (HEIS) Sample and Data Tracking subject area allows insertion of tracking information into a central repository where the data is immediately available for viewing. For example, a technical coordinator is able to view the current status of a particular sampling effort, from sample collection to data package validation dates. Four major types of data comprise the Sample and Data Tracking subject area: data about the mechanisms that groups a set of samples for a particular sampling effort; data about how constituents are grouped and assigned to a sample; data about when, where, and how samples are sent to a laboratory for analysis; and data bout the status of a sample's constituent analysis requirements, i.e., whether the analysis results have been returned from the laboratory

  16. A Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for In-Situ Mars Surface Sample Analysis

    Science.gov (United States)

    Edmunson, J.; Gaskin, J. A.; Jerman, G. A.; Harvey, R. P.; Doloboff, I. J.; Neidholdt, E. L.

    2016-01-01

    The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) project, funded by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Research Opportunities in Space and Earth Sciences (ROSES), will build upon previous miniaturized SEM designs and recent advancements in variable pressure SEM's to design and build a SEM to complete analyses of samples on the surface of Mars using the atmosphere as an imaging medium. This project is a collaboration between NASA Marshall Space Flight Center (MSFC), the Jet Propulsion Laboratory (JPL), electron gun and optics manufacturer Applied Physics Technologies, and small vacuum system manufacturer Creare. Dr. Ralph Harvery and environmental SEM (ESEM) inventor Dr. Gerry Danilatos serve as advisors to the team. Variable pressure SEMs allow for fine (nm-scale) resolution imaging and micron-scale chemical study of materials without sample preparation (e.g., carbon or gold coating). Charging of a sample is reduced or eliminated by the gas surrounding the sample. It is this property of ESEMs that make them ideal for locations where sample preparation is not yet feasible, such as the surface of Mars. In addition, the lack of sample preparation needed here will simplify the sample acquisition process and allow caching of the samples for future complementary payload use.

  17. Method and system for formation and withdrawal of a sample from a surface to be analyzed

    Science.gov (United States)

    Van Berkel, Gary J.; Kertesz, Vilmos

    2017-10-03

    A method and system for formation and withdrawal of a sample from a surface to be analyzed utilizes a collection instrument having a port through which a liquid solution is conducted onto the surface to be analyzed. The port is positioned adjacent the surface to be analyzed, and the liquid solution is conducted onto the surface through the port so that the liquid solution conducted onto the surface interacts with material comprising the surface. An amount of material is thereafter withdrawn from the surface. Pressure control can be utilized to manipulate the solution balance at the surface to thereby control the withdrawal of the amount of material from the surface. Furthermore, such pressure control can be coordinated with the movement of the surface relative to the port of the collection instrument within the X-Y plane.

  18. Dioxin-like activity of environmental compounds in human blood and environmental samples

    DEFF Research Database (Denmark)

    Long, Manhai; Bonefeld-Jørgensen, Eva Cecilie

    2012-01-01

    and humans. We found that some pesticides, plasticizers and phytoestrogens can activate the AhR, and the combined effect of compounds with no or weak AhR potency cannot be ignored. The significant DL-activity in the wastewater effluent indicates the treatment is not sufficient to prevent contamination...... of surface waters with dioxins. Our results from human studies suggest that the serum DL-activity reflect the complex mixture of persistent organic pollutants (POPs). Greenlandic Inuit had lower serum DL-activity level compared to Europeans, probably due to long distance from the dioxin sources and UV...

  19. The analysis study of plutonium in the environmental sample by mass spectrum combined with isotopic dilution

    International Nuclear Information System (INIS)

    Han Jun; Fu Zhonghua; Mao Xingen; Meng Fanben

    2004-01-01

    The technology of the rhenium filament carbonization was used to increase the ionization efficiency in this paper. The plutonium in the environmental sample was analyzed by Mass Spectrum combined with isotope dilution. Analysis of the 239 Pu blank in the process: The analysis of 239 Pu from the chemical process was carried out in order to establish the influence of the 239 Pu introduced from the process. The analysis results were shown in Table 1 sample 1 was not gone through the process, sample 2 and sample 3 were gone through the process. It was clear that there was no influence of the 239 Pu from the process within the deviation. Results and Discussions: The environmental samples which were dealed with the chemical method were prepared the sample of mass spectrum, The atomic ratio of the 239 Pu and 242 Pu in the environmental samples was measured by Mass Spectrum. The atomic ratio in the tracer 242 Pu was 0.01476±0.00007.The results for nuclide content in environment were given in Table 2. The content of 239 Pu in the tracer was high, so the existing of 239 Pu in the environmental samples can be determined by the changing of the atomic ratio of 242 Pu to 239 Pu. It was clear that there was 239 Pu in the environmental samples except the cypress leaves-2 and the pine leaves-3 within the deviation, and the content of 239 Pu were given in Table 2. Conclusion: a. Plutonium was separated and purified from the impurity by the anion-exchange and the electrodeposition, it was possible to provide the eligible mass spectrum sample. b. The measurement of plutonium in the environmental samples was not influenced by the flow of the background in the experiment. c. As the technology of the rhenium carbonization was used to increase the ionization efficiency, the content of plutonium which was about 10 -13 g in the environmental sample could be quantitatively analyzed by Mass Spectrum combined with isotope dilution. (authors)

  20. Recent advancements and future trends in environmental analysis: Sample preparation, liquid chromatography and mass spectrometry.

    Science.gov (United States)

    Pérez-Fernández, Virginia; Mainero Rocca, Lucia; Tomai, Pierpaolo; Fanali, Salvatore; Gentili, Alessandra

    2017-08-29

    Among the thousands of chemicals having potential to enter the environment, the NORMAN network has identified at least 700 substances categorized into 20 classes in the European surface waters. Pesticides, pharmaceuticals, disinfection by-products, wood preservation and industrial chemicals are the prominent classes. Since the impact of these substances on aquatic life and human health might be dramatic, action is urgently required at multiple levels; one of them is just related to the development of more and more sensible and selective analytical methods. This review highlights the latest advancements and trends in liquid chromatography-mass spectrometry based environmental analysis. Specific sections are dedicated to novelties in sample preparation, chromatographic separation and mass spectrometry detection of emerging pollutants. The review also offers insights on last generation chromatographic and extraction materials, technological progresses and innovative methodological approaches for target and non-target analysis. As numerous papers have been published in this field, this overview covers the most representative and original works published in the 2011-2016 period. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Microextraction Techniques Coupled to Liquid Chromatography with Mass Spectrometry for the Determination of Organic Micropollutants in Environmental Water Samples

    Directory of Open Access Journals (Sweden)

    Mª Esther Torres Padrón

    2014-07-01

    Full Text Available Until recently, sample preparation was carried out using traditional techniques, such as liquid–liquid extraction (LLE, that use large volumes of organic solvents. Solid-phase extraction (SPE uses much less solvent than LLE, although the volume can still be significant. These preparation methods are expensive, time-consuming and environmentally unfriendly. Recently, a great effort has been made to develop new analytical methodologies able to perform direct analyses using miniaturised equipment, thereby achieving high enrichment factors, minimising solvent consumption and reducing waste. These microextraction techniques improve the performance during sample preparation, particularly in complex water environmental samples, such as wastewaters, surface and ground waters, tap waters, sea and river waters. Liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS and time-of-flight mass spectrometric (TOF/MS techniques can be used when analysing a broad range of organic micropollutants. Before separating and detecting these compounds in environmental samples, the target analytes must be extracted and pre-concentrated to make them detectable. In this work, we review the most recent applications of microextraction preparation techniques in different water environmental matrices to determine organic micropollutants: solid-phase microextraction SPME, in-tube solid-phase microextraction (IT-SPME, stir bar sorptive extraction (SBSE and liquid-phase microextraction (LPME. Several groups of compounds are considered organic micropollutants because these are being released continuously into the environment. Many of these compounds are considered emerging contaminants. These analytes are generally compounds that are not covered by the existing regulations and are now detected more frequently in different environmental compartments. Pharmaceuticals, surfactants, personal care products and other chemicals are considered micropollutants. These

  2. Improved detection of multiple environmental antibiotics through an optimized sample extraction strategy in liquid chromatography-mass spectrometry analysis.

    Science.gov (United States)

    Yi, Xinzhu; Bayen, Stéphane; Kelly, Barry C; Li, Xu; Zhou, Zhi

    2015-12-01

    A solid-phase extraction/liquid chromatography/electrospray ionization/multi-stage mass spectrometry (SPE-LC-ESI-MS/MS) method was optimized in this study for sensitive and simultaneous detection of multiple antibiotics in urban surface waters and soils. Among the seven classes of tested antibiotics, extraction efficiencies of macrolides, lincosamide, chloramphenicol, and polyether antibiotics were significantly improved under optimized sample extraction pH. Instead of only using acidic extraction in many existing studies, the results indicated that antibiotics with low pK a values (antibiotics with high pK a values (>7) were extracted more efficiently under neutral conditions. The effects of pH were more obvious on polar compounds than those on non-polar compounds. Optimization of extraction pH resulted in significantly improved sample recovery and better detection limits. Compared with reported values in the literature, the average reduction of minimal detection limits obtained in this study was 87.6% in surface waters (0.06-2.28 ng/L) and 67.1% in soils (0.01-18.16 ng/g dry wt). This method was subsequently applied to detect antibiotics in environmental samples in a heavily populated urban city, and macrolides, sulfonamides, and lincomycin were frequently detected. Antibiotics with highest detected concentrations were sulfamethazine (82.5 ng/L) in surface waters and erythromycin (6.6 ng/g dry wt) in soils. The optimized sample extraction strategy can be used to improve the detection of a variety of antibiotics in environmental surface waters and soils.

  3. Characterization of Drain Surface Water: Environmental Profile, Degradation Level and Geo-statistic Monitoring

    International Nuclear Information System (INIS)

    Mumtaz, M.W.; Raza, M.A.; Ahmed, Z.; Abbas, M.N.; Hussain, M.

    2015-01-01

    The physico-chemical characterization of the surface water. Samples was carried out collected from nine sampling points of drain passing by the territory of Hafizabad city, Punjab, Pakistan. The water of drain is used by farmers for irrigation purposes in nearby agricultural fields. Twenty water quality parameters were evaluated in three turns and the results obtained were compared with the National Environmental Quality Standards (NEQS) municipal and industrial effluents prescribed limits. The highly significant difference (p<0.01) was recorded for the content of phenols, carbonyl compounds, cyanides, dissolved oxygen, biological oxygen demand, total soluble salts, total dissolved salts, nitrates and sulphates, whereas, the concentration of magnesium, potassium and oil and grease differed significantly (p<0.05) with respect to the sampling points on average basis. Non-significant difference (p>0.05) was noted for temperature, pH, electrical conductivity, hardness, calcium, sodium, chemical oxygen demand and chloride among water samples from different sampling points. Furthermore, the experimental results of different water quality parameters studied at nine sampling points of the drain were used and interpolated in ArcGIS 9.3 environment system using kriging techniques to obtain calculated values for the remaining locations of the Drain. (author)

  4. Environmental and emergency response capabilities of Los Alamos Scientific Laboratory's radiological air sampling program

    International Nuclear Information System (INIS)

    Gunderson, T.C.

    1980-05-01

    Environmental and emergency response radiological air sampling capabilities of the Environmental Surveillance Group at Los Alamos Scientific Laboratory are described. The air sampling program provides a supplementary check on the adequacy of containment and effluent controls, determines compliance with applicable protection guides and standards, and assesses potential environmental impacts on site environs. It also allows evaluation of potential individual and total population doses from airborne radionuclides that may be inhaled or serve as a source of external radiation. The environmental program is sufficient in scope to detect fluctuations and long-term trends in atmospheric levels of radioactivity originating onsite. The emergency response capabilities are designed to respond to both onsite unplanned releases and atmospheric nuclear tests

  5. Wet-digestion of environmental sample using silver-mediated electrochemical method

    International Nuclear Information System (INIS)

    Kuwabara, Jun

    2010-01-01

    An application of silver-mediated electrochemical method to environmental samples as the effective digestion method for iodine analysis was tried. Usual digestion method for 129 I in many type of environmental sample is combustion method using quartz glass tube. Chemical yield of iodine on the combustion method reduce depending on the type of sample. The silver-mediated electrochemical method is expected to achieve very low loss of iodine. In this study, dried kombu (Laminaria) sample was tried to digest with electrochemical cell. At the case of 1g of sample, digestion was completed for about 24 hours under the electric condition of <10V and <2A. After the digestion, oxidized species of iodine was reduced to iodide by adding sodium sulfite. And then the precipitate of silver iodide was obtained. (author)

  6. Study on auto-plating process time versus recovery for polonium, Po-210 in environmental sample

    International Nuclear Information System (INIS)

    Jalal Sharib; Zaharudin Ahmad; Abdul Kadir Ishak; Norfaizal Mohamed; Ahmad Sanadi Abu Bakar; Yii Mei Wo; Kamarozaman Ishak; Siti Aminah Yusoff

    2008-08-01

    This study was carried out to evaluate time effectiveness and recovery 16 samples of 4 Kuala Muda stations during auto-plating process procedures for determination Polonium, Po 210 activity concentration in environmental sample. The study was performed using Kuala Muda sediment as sample in the same methodology. The auto-plating process runs for 4, 12, 24 and 30 hours on a silver disc for 4 samples each station, and then counted for one (1) day using an alpha spectrometry counting system. The objectives for this study is to justify on time duration for auto-plating process effecting a chemical yield of Po-209.The results showed recovery are increasing versus time and constantly at 24 hour auto-plating. Its mean, 24 hour is an optimum time for auto-plating process for determination of Polonium, Po 210 activity concentration in environmental sample. (Author)

  7. Evaluation of oxidation techniques for preparing bioassay and environmental samples for liquid scintillation counting

    International Nuclear Information System (INIS)

    Miller, H.H.

    1979-10-01

    In environmental and biological monitoring for carbon-14 and tritium, the presence of color and chemical quenching agents in the samples can degrade the efficiency of liquid scintillation counting. A series of experiments was performed to evaluate the usefulness, under routine conditions, of first oxidizing the samples to improve the counting by removing the color and quenching agents. The scintillation counter was calibrated for the effects of quenching agents on its counting efficiency. Oxidizing apparatus was tested for its ability to accurately recover the 14 C and 3 H in the samples. Scintillation counting efficiences were compared for a variety of oxidized and unoxidized environmental and bioassay samples. The overall conclusion was that, for routine counting, oxidation of such samples is advantageous when they are highly quenched or in solid form

  8. Rapid and Automated Determination of Plutonium and Neptunium in Environmental Samples

    DEFF Research Database (Denmark)

    Qiao, Jixin

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development...... and optimization for rapid determination of plutonium in environmental samples using SIextraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples...... for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including...

  9. Determination of 237Np in environmental and nuclear samples: A review of the analytical method

    International Nuclear Information System (INIS)

    Thakur, P.; Mulholland, G.P.

    2012-01-01

    A number of analytical methods has been developed and used for the determination of neptunium in environmental and nuclear fuel samples using alpha, ICP–MS spectrometry, and other analytical techniques. This review summarizes and discusses development of the radiochemical procedures for separation of neptunium (Np), since the beginning of the nuclear industry, followed by a more detailed discussion on recent trends in the separation of neptunium. This article also highlights the progress in analytical methods and issues associated with the determination of neptunium in environmental samples. - Highlights: ► Determination of Np in environmental and nuclear samples is reviewed. ► Various analytical methods used for the determination of Np are listed. ► Progress and issues associated with the determination of Np are discussed.

  10. AFM fluid delivery/liquid extraction surface sampling/electrostatic spray cantilever probe

    Science.gov (United States)

    Van Berkel, Gary J.

    2015-06-23

    An electrospray system comprises a liquid extraction surface sampling probe. The probe comprises a probe body having a liquid inlet and a liquid outlet, and having a liquid extraction tip. A solvent delivery conduit is provided for receiving solvent liquid from the liquid inlet and delivering the solvent liquid to the liquid extraction tip. An open liquid extraction channel extends across an exterior surface of the probe body from the liquid extraction tip to the liquid outlet. An electrospray emitter tip is in liquid communication with the liquid outlet of the liquid extraction surface sampling probe. A system for analyzing samples, a liquid junction surface sampling system, and a method of analyzing samples are also disclosed.

  11. Analytical laboratory quality assurance guidance in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-05-01

    This document introduces QA guidance pertaining to design and implementation of laboratory procedures and processes for collecting DOE Environmental Restoration and Waste Management (EM) ESAA (environmental sampling and analysis activities) data. It addresses several goals: identifying key laboratory issues and program elements to EM HQ and field office managers; providing non-prescriptive guidance; and introducing environmental data collection program elements for EM-263 assessment documents and programs. The guidance describes the implementation of laboratory QA elements within a functional QA program (development of the QA program and data quality objectives are not covered here)

  12. Rapid and automated determination of plutonium and neptunium in environmental samples

    International Nuclear Information System (INIS)

    Qiao, J.

    2011-03-01

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development in this work consists of 5 subjects stated as follows: 1) Development and optimization of an SI-anion exchange chromatographic method for rapid determination of plutonium in environmental samples in combination of inductively coupled plasma mass spectrometry detection (Paper II); (2) Methodology development and optimization for rapid determination of plutonium in environmental samples using SI-extraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples (Paper IV); (4) Investigation of the suitability and applicability of 242 Pu as a tracer for rapid neptunium determination using anion exchange chromatography in an SI-network coupled with inductively coupled plasma mass spectrometry (Paper V); (5) Exploration of macro-porous anion exchange chromatography for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including environmental risk monitoring and assessment, emergency preparedness and surveillance of contaminated areas. (Author)

  13. Rapid and automated determination of plutonium and neptunium in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Qiao, J.

    2011-03-15

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development in this work consists of 5 subjects stated as follows: 1) Development and optimization of an SI-anion exchange chromatographic method for rapid determination of plutonium in environmental samples in combination of inductively coupled plasma mass spectrometry detection (Paper II); (2) Methodology development and optimization for rapid determination of plutonium in environmental samples using SI-extraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples (Paper IV); (4) Investigation of the suitability and applicability of 242Pu as a tracer for rapid neptunium determination using anion exchange chromatography in an SI-network coupled with inductively coupled plasma mass spectrometry (Paper V); (5) Exploration of macro-porous anion exchange chromatography for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including environmental risk monitoring and assessment, emergency preparedness and surveillance of contaminated areas. (Author)

  14. Note: Radio frequency surface impedance characterization system for superconducting samples at 7.5 GHz.

    Science.gov (United States)

    Xiao, B P; Reece, C E; Phillips, H L; Geng, R L; Wang, H; Marhauser, F; Kelley, M J

    2011-05-01

    A radio frequency (RF) surface impedance characterization (SIC) system that uses a novel sapphire-loaded niobium cavity operating at 7.5 GHz has been developed as a tool to measure the RF surface impedance of flat superconducting material samples. The SIC system can presently make direct calorimetric RF surface impedance measurements on the central 0.8 cm(2) area of 5 cm diameter disk samples from 2 to 20 K exposed to RF magnetic fields up to 14 mT. To illustrate system utility, we present first measurement results for a bulk niobium sample.

  15. Analyses and Comparison of Bulk and Coil Surface Samples from the DWPF Slurry Mix Evaporator

    International Nuclear Information System (INIS)

    Hay, M.; Nash, C.; Stone, M.

    2012-01-01

    Sludge samples from the DWPF Slurry Mix Evaporator (SME) heating coil frame and coil surface were characterized to identify differences that might help identify heat transfer fouling materials. The SME steam coils have seen increased fouling leading to lower boil-up rates. Samples of the sludge were taken from the coil frame somewhat distant from the coil (bulk tank material) and from the coil surface (coil surface sample). The results of the analysis indicate the composition of the two SME samples are very similar with the exception that the coil surface sample shows ∼5-10X higher mercury concentration than the bulk tank sample. Elemental analyses and x-ray diffraction results did not indicate notable differences between the two samples. The ICP-MS and Cs-137 data indicate no significant differences in the radionuclide composition of the two SME samples. Semi-volatile organic analysis revealed numerous organic molecules, these likely result from antifoaming additives. The compositions of the two SME samples also match well with the analyzed composition of the SME batch with the exception of significantly higher silicon, lithium, and boron content in the batch sample indicating the coil samples are deficient in frit relative to the SME batch composition.

  16. Some analytical aspects about determination of Sr89 and Sr90 in environmental samples

    International Nuclear Information System (INIS)

    Gasco, C.; Alvarez Garcia, A.

    1988-01-01

    Some problems about determination of Sr 89 and Sr 90 in environmental samples have been studied. The main difficulties are due to the wide range in the concentration of their components and the contents of chemical and radiochemical interferent elements. The behaviour of strontium on ion exchange resin has been described by some experiments in various media: aqueous media, calcium concentration and matrix variable. The differences of alkaline-earth nitrate and carbonate solubilities have been analyzed in nitric acid. The chemical recovery in environmental samples has been determined. (Author)

  17. Metagenomic analyses of novel viruses and plasmids from a cultured environmental sample of hyperthermophilic neutrophiles

    DEFF Research Database (Denmark)

    Garrett, Roger Antony; Prangishvili, David; Shah, Shiraz Ali

    2010-01-01

    Two novel viral genomes and four plasmids were assembled from an environmental sample collected from a hot spring at Yellowstone National Park, USA, and maintained anaerobically in a bioreactor at 85°C and pH 6. The double-stranded DNA viral genomes are linear (22.7 kb) and circular (17.7 kb...... respectively. Strategies are considered for assembling genomes of smaller genetic elements from complex environmental samples, and for establishing possible host identities on the basis of sequence similarity to host CRISPR immune systems....

  18. Helium-3 mass spectrometry for low-level tritium analysis of environmental samples

    International Nuclear Information System (INIS)

    Surano, K.A.; Hudson, G.B.; Failor, R.A.; Sims, J.M.; Holland, R.C.; MacLean, S.C.; Garrison, J.C.

    1991-04-01

    Helium-3 ( 3 He) mass spectrometry for the analysis of low-level tritium ( 3 H) concentrations in environmental sample matrices was compared with conventional low-level β-decay counting methods. The mass-spectrometry method compared favorably, equaling or surpassing conventional decay-counting methods with respect to most criteria. Additional research and method refinements may make 3 He mass spectrometry the method of choice for routine, low-level to very-low-level 3 H measurements in a wide variety of environmental samples in the future

  19. The role of NAA in the environmental studies. Quantitative determination of heavy metals pollutant on environmental samples

    International Nuclear Information System (INIS)

    Sutisna; Yusuf, Saeful; Fisli, Adel; Rukihati; Wardhani, Sri; Th Rina M

    2003-01-01

    The neutron activation analysis technique was applied in the elemental analysis of environmental samples to solve an environmental pollution problem. We focused our study in the analysis of heavy metal which has potentially become a pollutant. The environmental samples analyzed were some water, sediment and an air particulate matter. The tap water sample was collected from five samplings points located at region of Serpong and Muria. Meanwhile the river water samples were taken from five samplings points of Ciliwung River. Eight samplings points of Cisadane river estuary located at Tanjung Burung were selected to collect sediment samples. Air particulate samples were collected from Jakarta Metropolitan and Serpong using high volume air sampler. Trace elements analyses of water samples were done using a combination of INAA and pre-concentration stage prior irradiation. All samples were irradiated at GA. Siwabessy reactor located at Serpong using a thermal neutron flux of about 10 12 n.cm -2 .sec -1 . After cooling time, the samples irradiated were counted by a high resolution HPGe detector coupled to a multichannel analyzer. The quantitative analyses have been done using a comparative method to a fresh laboratory standard and we used some standard references materials to validate our analytical result. The obtained result from the tap water analysis show that the elements of As, Cr, Co, Cd, Mn, Sb and Zn could be determine quantitatively and they have a concentration range from about 0.02 μg/L to 103.9 μg/L. The analysis result of Ciliwung river water samples show that elements of Ag, As, Co, Cu, Fe, Hg, Mn, V and Zn are present in the range of 2.4 μg/L to about 1365.8 μg/L. Meanwhile some important elements were obtained in the sediments samples taken from Cisadane River estuary such as Ce (40.4 - 63.6 mg/kg), Co (15.2 - 40.2 mg/kg), Cr (21.6 - 57.8 mg/kg), Eu (1.2 - 1.8 mg/kg), Fe (7.0 - 16.8 mg/kg), Mn (887 - 1810 mg/kg) and V (160 - 558 mg/kg). Finally the

  20. The role of NAA in the environmental studies. Quantitative determination of heavy metals pollutant on environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Sutisna; Yusuf, Saeful; Fisli, Adel; Rukihati; Wardhani, Sri; Th Rina M [National Nuclear Energy Agency of Indonesia, Kawasan Puspiptek, Serpong (Indonesia)

    2003-03-01

    The neutron activation analysis technique was applied in the elemental analysis of environmental samples to solve an environmental pollution problem. We focused our study in the analysis of heavy metal which has potentially become a pollutant. The environmental samples analyzed were some water, sediment and an air particulate matter. The tap water sample was collected from five samplings points located at region of Serpong and Muria. Meanwhile the river water samples were taken from five samplings points of Ciliwung River. Eight samplings points of Cisadane river estuary located at Tanjung Burung were selected to collect sediment samples. Air particulate samples were collected from Jakarta Metropolitan and Serpong using high volume air sampler. Trace elements analyses of water samples were done using a combination of INAA and pre-concentration stage prior irradiation. All samples were irradiated at GA. Siwabessy reactor located at Serpong using a thermal neutron flux of about 10{sup 12} n.cm{sup -2}.sec{sup -1}. After cooling time, the samples irradiated were counted by a high resolution HPGe detector coupled to a multichannel analyzer. The quantitative analyses have been done using a comparative method to a fresh laboratory standard and we used some standard references materials to validate our analytical result. The obtained result from the tap water analysis show that the elements of As, Cr, Co, Cd, Mn, Sb and Zn could be determine quantitatively and they have a concentration range from about 0.02 {mu}g/L to 103.9 {mu}g/L. The analysis result of Ciliwung river water samples show that elements of Ag, As, Co, Cu, Fe, Hg, Mn, V and Zn are present in the range of 2.4 {mu}g/L to about 1365.8 {mu}g/L. Meanwhile some important elements were obtained in the sediments samples taken from Cisadane River estuary such as Ce (40.4 - 63.6 mg/kg), Co (15.2 - 40.2 mg/kg), Cr (21.6 - 57.8 mg/kg), Eu (1.2 - 1.8 mg/kg), Fe (7.0 - 16.8 mg/kg), Mn (887 - 1810 mg/kg) and V (160 - 558

  1. Determination of 90Sr in environmental samples by microwave assisted digestion - chromatographic separation

    International Nuclear Information System (INIS)

    Torres, J.M.; Llaurado, M.; Rauret, G.

    1998-01-01

    The stages involved in the determination of 90 Sr in environmental samples are: sample attack, radiochemical separation (of both 90 Sr and its progeny 90 Y) and measurement. For the determination of 90 Sr, the introduction of microwave-assisted digestion methods has improved acid attack by drastically decreasing both digestion time and the volume of acidic reagents. Recent studies describe many applications of microwave-assisted methods for the determination of inorganic and organometallic compounds in several matrices. We have recently studied the microwave-assisted digestion of soils for the 90 Sr determination. The presented work extends the application of microwaves for the 90 Sr determination to other environmental samples such as sediments, vegetation and milk. An open-focused microwave system, which accepts large samples intakes usually required for radioanalytical chemistry due to the low level content of radionuclides in environmental samples, was used. This system can handle up to 10 g of sample intake which, in many cases, is enough to have acceptable limits of detection. Different digestion procedures are optimised for each matrix studied, paying special attention to the microwave power, the time of digestion and the volume of acidic reagents. Once the sample is in solution a new separation procedure using a specific resin -Sr.Spec- is applied and the measurement is performed by liquid scintillation. The results obtained are compared with a previously optimised method based on liquid-liquid extraction of 90 Y and Cerenkov radiation measurement

  2. Study of Efficiency Calibrations of HPGe Detectors for Radioactivity Measurements of Environmental Samples

    International Nuclear Information System (INIS)

    Harb, S.; Salahel Din, K.; Abbady, A.

    2009-01-01

    In this paper, we describe a method of calibrating of efficiency of a HPGe gamma-ray spectrometry of bulk environmental samples (Tea, crops, water, and soil) is a significant part of the environmental radioactivity measurements. Here we will discuss the full energy peak efficiency (FEPE) of three HPGe detectors it as a consequence, it is essential that the efficiency is determined for each set-up employed. Besides to take full advantage at gamma-ray spectrometry, a set of efficiency at several energies which covers the wide the range in energy, the large the number of radionuclides whose concentration can be determined to measure the main natural gamma-ray emitters, the efficiency should be known at least from 46.54 keV ( 210 Pb) to 1836 keV ( 88 Y). Radioactive sources were prepared from two different standards, a first mixed standard QC Y 40 containing 210 Pb, 241 Am, 109 Cd, and Co 57 , and the second QC Y 48 containing 241 Am, 109 Cd, 57 Co, 139 Ce, 113 Sn, 85 Sr, 137 Cs, 88 Y, and 60 Co is necessary in order to calculate the activity of the different radionuclides contained in a sample. In this work, we will study the efficiency calibration as a function of different parameters as:- Energy of gamma ray from 46.54 keV ( 210 Pb) to 1836 keV ( 88 Y), three different detectors A, B, and C, geometry of containers (point source, marinelli beaker, and cylindrical bottle 1 L), height of standard soil samples in bottle 250 ml, and density of standard environmental samples. These standard environmental sample must be measured before added standard solution because we will use the same environmental samples in order to consider the self absorption especially and composition in the case of volume samples.

  3. Health and Safety Laboratory environmental quarterly, March 1--June 1, 1976. [Fallout, natural radioactivity, and lead in environmental samples from USA, India, and Taiwan during 1976

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, E.P. Jr.

    1976-07-01

    This report presents current data from the HASL environmental programs, the Air Monitoring Section of the Bhabha Atomic Research Center in India, the Health Physics Section of the Institute of Nuclear Science in Taiwan and the Radiological and Environmental Research Division at Argonne National Laboratory. The initial section consists of interpretive reports and notes on the history of long-range fallout, cesium-137 in Bombay milk, natural and fallout radioactivity in Indian diet, reporting results of radioactivity measurements at near zero levels of sample activity and background, plutonium in soil northeast of the Nevada Test Site, radon levels at the Lloyd, NY regional station, strontium-90 in New York and San Francisco diets through 1975, plutonium-239, 240 in 1974 diet, up-dating stratospheric radionuclide inventories to July 1975 and a revised table of radionuclides. Subsequent sections include tabulations of radionuclide levels in stratospheric air; lead and radionuclides in surface air; strontium-90 in deposition, milk, diet, tap water, and human bone; cesium-137 in Chicago foods in April 1976; and environmental radioactivity surveys for nuclear power plants in North Taiwan. A bibliography of recent publications related to environmental studies is also presented.

  4. Environmental geochemistry of surface and subsurface water from Dera Ismail Khan Division, Khyber Pakhtunkhwa, Pakistan

    International Nuclear Information System (INIS)

    Shah, M.T.; Alizai, A.H.; Khan, S.D.

    2012-01-01

    The Dera Ismail Khan division is situated in the southern most part of the Khyber-Pakhtunkhwa province in Pakistan. Majority of population in this region obtain domestic water from tube wells, dug wells, ponds, stored run off of the Indus and Gomal rivers and perennial streams. This study is aimed to determine the physio-chemical contaminants in the surface and subsurface water which could cause environmental problem. For this purpose, representative water sample were collected from tube wells, dug wells, streams and rivers. These analyses were performed using Hach DR/2000 spectrophotometer and graphite furnace atomic absorption spectrometer. Chemically both surface and subsurface water samples of the area were classified as alkaline fresh water. The comparison of the data with standard limits set by Word Health Organization (WHO) for drinking water suggested that in certain areas of the division, the drinking water samples have high concentrations of Total Dissolved Solids, NO/sub 3//sup 2-/, SO/sub 4//sup 2-/, F-, Cl-, Fe/sup 2+/, Ca/sup 2+/, Mg/sup 2+/, Pb/sup 2+/, Ni/sup 2+/ and Cd/sup 2+/ while pH, EC, HCO/sub 3/-, PO/sub 4//sup 3-/, Na/sup +/, Mn/sup 2+/, K/sup +/, Cr/sup 3+/ and Zn/sup 2+/ were within the permissible limits. These contaminations could be attributed to the geogenic sources which might be responsible for the health related problems in certain areas of the division. (author)

  5. An intrinsic algorithm for parallel Poisson disk sampling on arbitrary surfaces.

    Science.gov (United States)

    Ying, Xiang; Xin, Shi-Qing; Sun, Qian; He, Ying

    2013-09-01

    Poisson disk sampling has excellent spatial and spectral properties, and plays an important role in a variety of visual computing. Although many promising algorithms have been proposed for multidimensional sampling in euclidean space, very few studies have been reported with regard to the problem of generating Poisson disks on surfaces due to the complicated nature of the surface. This paper presents an intrinsic algorithm for parallel Poisson disk sampling on arbitrary surfaces. In sharp contrast to the conventional parallel approaches, our method neither partitions the given surface into small patches nor uses any spatial data structure to maintain the voids in the sampling domain. Instead, our approach assigns each sample candidate a random and unique priority that is unbiased with regard to the distribution. Hence, multiple threads can process the candidates simultaneously and resolve conflicts by checking the given priority values. Our algorithm guarantees that the generated Poisson disks are uniformly and randomly distributed without bias. It is worth noting that our method is intrinsic and independent of the embedding space. This intrinsic feature allows us to generate Poisson disk patterns on arbitrary surfaces in IR(n). To our knowledge, this is the first intrinsic, parallel, and accurate algorithm for surface Poisson disk sampling. Furthermore, by manipulating the spatially varying density function, we can obtain adaptive sampling easily.

  6. Determination of short-lived trace elements in environmental samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Wardani, S.; Sihombing, E.; Hamzah, A.; Rochidi; Hery, P.S.; Hartaman, S.; Iman, J.

    1998-01-01

    Concentration of a short-lived trace elements in environmental samples were determined by neutron activation analysis, a counting loss often occur due to the high counting rate. A Pile-Up Rejecter (PUR) electric circuit was installed in counting a short-lived trace elements by a γ-ray spectrometer in order to correct a counting loss. The samples were irradiated for 30∼60 seconds at neutron flux of 3.5 x 10 12 n.cm -2 .s -1 , then the samples cooled for 120 second and counted for 180 second using this system. The nuclides concentration in the varieties environmental samples have a difference analysis result, was more accurate and precise, which the measured result would be 30 % more higher by PUR system than the result would be counted using a conventional γ-ray spectrometry method

  7. A semi-empirical approach to calculate gamma activities in environmental samples

    International Nuclear Information System (INIS)

    Palacios, D.; Barros, H.; Alfonso, J.; Perez, K.; Trujillo, M.; Losada, M.

    2006-01-01

    We propose a semi-empirical method to calculate radionuclide concentrations in environmental samples without the use of reference material and avoiding the typical complexity of Monte-Carlo codes. The calculation of total efficiencies was carried out from a relative efficiency curve (obtained from the gamma spectra data), and the geometric (simulated by Monte-Carlo), absorption, sample and intrinsic efficiencies at energies between 130 and 3000 keV. The absorption and sample efficiencies were determined from the mass absorption coefficients, obtained by the web program XCOM. Deviations between computed results and measured efficiencies for the RGTh-1 reference material are mostly within 10%. Radionuclide activities in marine sediment samples calculated by the proposed method and by the experimental relative method were in satisfactory agreement. The developed method can be used for routine environmental monitoring when efficiency uncertainties of 10% can be sufficient.(Author)

  8. An improved combustion apparatus for the determination of organically bound tritium in environmental samples

    International Nuclear Information System (INIS)

    Du, Lin; Shan, Jian; Ma, Yu-Hua; Wang, Ling; Qin, Lai-Lai; Pi, Li; Zeng, You-Shi; Xia, Zheng-Hai; Wang, Guang-Hua; Liu, Wei

    2016-01-01

    This paper reports an improved combustion apparatus for the determination of organically bound tritium in environmental samples. The performance of this apparatus including the recovery rate and reproducibility was investigated by combusting lettuce and pork samples. To determine the factors for the different recovery rates of lettuce and pork and investigate whether the samples were completely oxidized, the ashes and exhaust gases produced by the combustion were analyzed. The results indicate that the apparatus showed an excellent performance in the combustion of environmental samples. Thus, the improvements conducted in this study were effective. - Highlights: • Three major improvements were made to develop the combustion apparatus for OBT. • The recovery is higher and more stable than that of current equipment. • Little hydrogen was present in the ashes and exhaust after combustion.

  9. The determination of arsenic, selenium, antimony, and tin in complex environmental samples by hydride generation AAS

    International Nuclear Information System (INIS)

    Johnson, D.; Beach, C.

    1990-01-01

    Hydride generation techniques are used routinely for the determination of As, Se, Sb and Sn in water samples. Advantages include high sensitivity, simplicity, and relative freedom from interferences. Continuous-flow designs greatly reduce analysis time as well as improve precision and allow for automation. However the accurate analysis of more complex environmental samples such as industrial sludges, soil samples, river sediments, and fly ash remains difficult. Numerous contributing factors influence the accuracy of the hydride technique. Sample digestion methods and sample preparation procedures are of critical importance. The digestion must adequately solubilize the elements of interest without loss by volatilization. Sample preparation procedures that guarantee the proper analyte oxidation state and eliminate the nitric acid and inter-element interferences are needed. In this study, difficult environmental samples were analyzed for As, Se, Sb, and Sn by continuous flow hydride generation. Sample preparation methods were optimized to eliminate interferences. The results of spike recovery studies will be presented. Data from the analysis of the same samples by graphite furnace AAS will be presented for comparison of accuracy, precision, and analysis time

  10. Isotope dilution surface ionization mass spectrometry of silver in environmental materials

    Energy Technology Data Exchange (ETDEWEB)

    Murozumi, M; Nakamura, S; Suga, K [Muroran Inst. of Tech., Hokkaido (Japan)

    1981-03-01

    Surface ionization mass spectrometry has been developed to measure isotopic abundances and concentrations of silver in commercial high-purity metals, environmental materials such as rocks and plants, and /sup 109/Ag and /sup 107/Ag spikes. A minute amount of silver is extracted into a dithizone chloroform solution from a nitric acid solution of above samples. After the silver is back-extracted into 6.0 ml of a 7 mol/l HNO/sub 3/ solution, the solution is evaporated to dryness under the nitrogen atmosphere. Silver nitrate thus formed is dissolved in a mixture of 60 ..mu..l of an 0.003% silica gel suspended water and 5 ..mu..l of a 2% phosphoric acid. An aliquot of this solution is applied to the mass spectrometry using a rhenium single filament as an ion emitter. The proposed method can detect the presence of 10/sup -14/ g of silver on the ion emitter, and measure the /sup 109/Ag//sup 107/Ag isotopic ratio in environmental materials with the accuracy of 0.1 -- 0.2% in the coefficient of variation. Isotope dilution mass spectrometry using a /sup 107/Ag spike has revealed the silver concentration in the environmental standard materials, which were prepared by the National Bureau of Standards, U.S.A. and National Institute of Environmental Studies of Japan, as follows; 27.9 +- 0.2 ppb for the Orchard Leaves and 34.3 +- 0.3 ppb in the Pepper Bush. The determined values of silver in the Granodiorite, JG-1, and Basalt, JB-1 powders made by the Geological Survey of Japan are 25.4 +- 0.4 ppb and 41.3 +- 0.1 ppb respectively. Silver concentration in a coastal sea water sample is found to be at the level of 2.5 +- 0.4 ppt.

  11. Mathematical estimation of the level of microbial contamination on spacecraft surfaces by volumetric air sampling

    Science.gov (United States)

    Oxborrow, G. S.; Roark, A. L.; Fields, N. D.; Puleo, J. R.

    1974-01-01

    Microbiological sampling methods presently used for enumeration of microorganisms on spacecraft surfaces require contact with easily damaged components. Estimation of viable particles on surfaces using air sampling methods in conjunction with a mathematical model would be desirable. Parameters necessary for the mathematical model are the effect of angled surfaces on viable particle collection and the number of viable cells per viable particle. Deposition of viable particles on angled surfaces closely followed a cosine function, and the number of viable cells per viable particle was consistent with a Poisson distribution. Other parameters considered by the mathematical model included deposition rate and fractional removal per unit time. A close nonlinear correlation between volumetric air sampling and airborne fallout on surfaces was established with all fallout data points falling within the 95% confidence limits as determined by the mathematical model.

  12. Determination of carbon-14 environmental samples by mixing 14CO2 with a liquid scintillator

    International Nuclear Information System (INIS)

    Garcia Sanz, M.R.; Gomez, V.; Heras, M.C.; Beltran, M.A.

    1990-01-01

    A method for the determination of Carbon-14 ( 14 CO 2 ) in environmental samples has been developed. The method use the direct absorption of the carbon dioxide into Carbosorb, followed with incorporation of the mixture (Carbosorb-CO 2 ) to the liquid scintillator. The results obtained to apply this method and the benzene synthesis, usual in our laboratory, are discused and compared. The method of collection of atmospheric samples is also described. (Author)

  13. Method for the concentration and separation of actinides from biological and environmental samples

    International Nuclear Information System (INIS)

    Horwitz, E.P.; Dietz, M.L.

    1989-01-01

    A method and apparatus for the quantitative recover of actinide values from biological and environmental sample by passing appropriately prepared samples in a mineral acid solution through a separation column of a dialkyl(phenyl)-N,N-dialylcarbamoylmethylphosphine oxide dissolved in tri-n-butyl phosphate on an inert substrate which selectively extracts the actinide values. The actinide values can be eluted either as a group or individually and their presence quantitatively detected by alpha counting. 3 figs

  14. Determination of Sr-90 in environmental samples using solid phase extraction disk

    International Nuclear Information System (INIS)

    Zal U'yun Wan Mahmood

    2002-01-01

    A method is described for determination of Sr-90 in environmental samples using solid phase extraction disk (Empore TM Strontium Rad Disk) and GM counter. To determine the optimum condition for capacity of Empore TM Strontium Rad Disk, its characterization studies such as the effects Sr content, acidity (molarity) of acids, presence of Ca 2+ and other major ions (Na + , Mg 2+ etc), influence of interference (Pb and Bi) and others were carried out. An optimized the using of Empore TM Strontium Rad Disk for determination of Sr-90 was validated by application to environmental samples. Quantitative recoveries above 95%for Sr (stable) were recorded in 6M HCl condition. Typical environmental samples may contain an assortment of anionic and cationic species, but in general, Empore TM Strontium Rad Disk has enough capacity to effectively separate Sr for wide variety of aqueous solutions. Sr recovery in a matrix-free or the content of matrix less than 300 mg/sample is typically greater than 99% is reported in this research work. In particular, sample, which may contain interference such as Pb and Bi would require an addition separation step before processing to ensure an accurate measurement of Sr. In this research work, radiotracer 85 Sr was used to monitor the behavior of Sr and calculation its recovery. For analytical methods that can count Y-90, the Sr-90 activity/concentration in environmental sample was calculated. The concentration of Sr-90 in ash sample (Quality Controled Sample) of 276 ± 18 Bq/kg ash was determined from Y-90 activity. The relative percent difference of 1.1% was achievable for Empore TM Sr-Rad Disk methods when compared to the conventional method (fumed-HNO 3 method) - 279 ± 11 Bq/kg ash. (Author)

  15. Description of work for routine groundwater sampling at the Environmental Restoration Disposal Facility

    International Nuclear Information System (INIS)

    Ford, B.H.

    1996-09-01

    This document provides a description of work and field implementation guidance for routine (post-baseline) groundwater monitoring sampling program at the Environmental Restoration Disposal Facility. The purpose of this program is to (1) meet the intent of the applicable or relevant and appropriate requirements; (2) document baseline groundwater conditions; (3) monitor those conditions for change; and (4) allow for modifications to groundwater sampling if required by the leachate management program

  16. Determination of Carbon-14 in environmental samples by mixing 14CO2 with a liquid scintillator

    International Nuclear Information System (INIS)

    Garcia, M. R.; Gomez, V.; Heras, M. C.; Beltran, M. A.

    1990-01-01

    A method for the determination of Carbon-14 (14CO2) in environmental samples has been developed. The method use the direct absorption of the carbon dioxide into Carbosorb, followed with incorporation of the mixture (Carbosorb-CO2) to the liquid scintillator. The results obtained to apply this method and the benzene synthesis, usual in our laboratory, are discussed and compared. The method of collection of atmospheric samples is also described. (Author) 10 refs

  17. Determination of artificial and natural radionuclides and others trace elements in environmental samples form Antarctica

    International Nuclear Information System (INIS)

    Schuch, L.A.; Godoy, J.M.; Nordemann, D.J.R.

    1994-01-01

    The results of the radioactive elements concentrations, determined by gamma spectrometry and the others trace elements determined by neutron activation analysis of several environmental samples (soils, marine sediments, algae mosses and lichens) in Comandante Ferraz Antartica Station are presented. The high concentrations of Cs-137 were found in lichens and mosses samples and the soils and sediments showed concentrations of natural radionuclides. (C.G.C.). 8 refs, 1 fig, 3 tabs

  18. Master schedule for CY-1984 Hanford environmental surveillance routine sampling program

    International Nuclear Information System (INIS)

    Blumer, P.J.; Price, K.R.; Eddy, P.A.; Carlile, J.M.V.

    1983-12-01

    This report provides the current schedule of data collection for the routine Hanford environmental surveillance and ground-water Monitoring Programs at the Hanford Site. The purpose is to evaluate and report the levels of radioactive and nonradioactive pollutants in the Hanford environs. The routine sampling schedule provided herein does not include samples that are planned to be collected during FY-1984 in support of special studies, special contractor support programs, or for quality control purposes

  19. Systematic review and consensus guidelines for environmental sampling of Burkholderia pseudomallei.

    Directory of Open Access Journals (Sweden)

    Direk Limmathurotsakul

    Full Text Available Burkholderia pseudomallei, a Tier 1 Select Agent and the cause of melioidosis, is a Gram-negative bacillus present in the environment in many tropical countries. Defining the global pattern of B. pseudomallei distribution underpins efforts to prevent infection, and is dependent upon robust environmental sampling methodology. Our objective was to review the literature on the detection of environmental B. pseudomallei, update the risk map for melioidosis, and propose international consensus guidelines for soil sampling.An international working party (Detection of Environmental Burkholderia pseudomallei Working Party (DEBWorP was formed during the VIth World Melioidosis Congress in 2010. PubMed (January 1912 to December 2011 was searched using the following MeSH terms: pseudomallei or melioidosis. Bibliographies were hand-searched for secondary references. The reported geographical distribution of B. pseudomallei in the environment was mapped and categorized as definite, probable, or possible. The methodology used for detecting environmental B. pseudomallei was extracted and collated. We found that global coverage was patchy, with a lack of studies in many areas where melioidosis is suspected to occur. The sampling strategies and bacterial identification methods used were highly variable, and not all were robust. We developed consensus guidelines with the goals of reducing the probability of false-negative results, and the provision of affordable and 'low-tech' methodology that is applicable in both developed and developing countries.The proposed consensus guidelines provide the basis for the development of an accurate and comprehensive global map of environmental B. pseudomallei.

  20. Empirical insights and considerations for the OBT inter-laboratory comparison of environmental samples.

    Science.gov (United States)

    Kim, Sang-Bog; Roche, Jennifer

    2013-08-01

    Organically bound tritium (OBT) is an important tritium species that can be measured in most environmental samples, but has only recently been recognized as a species of tritium in these samples. Currently, OBT is not routinely measured by environmental monitoring laboratories around the world. There are no certified reference materials (CRMs) for environmental samples. Thus, quality assurance (QA), or verification of the accuracy of the OBT measurement, is not possible. Alternatively, quality control (QC), or verification of the precision of the OBT measurement, can be achieved. In the past, there have been differences in OBT analysis results between environmental laboratories. A possible reason for the discrepancies may be differences in analytical methods. Therefore, inter-laboratory OBT comparisons among the environmental laboratories are important and would provide a good opportunity for adopting a reference OBT analytical procedure. Due to the analytical issues, only limited information is available on OBT measurement. Previously conducted OBT inter-laboratory practices are reviewed and the findings are described. Based on our experiences, a few considerations were suggested for the international OBT inter-laboratory comparison exercise to be completed in the near future. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  1. Rapid Surface Sampling and Archival Record (RSSAR) System. Topical report, October 1, 1993--December 31, 1994

    International Nuclear Information System (INIS)

    1997-01-01

    This report describes the results of Phase 1 efforts to develop a Rapid Surface Sampling and Archival Record (RSSAR) System for the detection of semivolatile organic contaminants on concrete, transite, and metal surfaces. The characterization of equipment and building surfaces for the presence of contaminants as part of building decontamination and decommissioning activities is an immensely large tacks of concern to both government and industry. Contaminated and clean materials must be clearly identified and segregated so that the clean materials can be recycled or reused, if possible, or disposed of more cheaply as nonhazardous waste. Characterization of building and equipment surfaces will be needed during initial investigations, during cleanup operations, and during the final confirmatory process, increasing the total number of samples well beyond that needed for initial characterization. This multiplicity of information places a premium on the ability to handle and track data as efficiently as possible. Aware of the shortcomings of traditional surface characterization technology, GE, with DOE support has undertaken a 12-month effort to complete Phase 1 of a proposed four-phase program to develop the RSSAR system. The objectives of this work are to provide instrumentation to cost-effectively sample concrete and steel surfaces, provide a quick-look indication for the presence or absence of contaminants, and collect samples for later, more detailed analysis in a readily accessible and addressable form. The Rapid Surface Sampling and Archival Record (RSSAR) System will be a modular instrument made up of several components: (1) sampling heads for concrete surfaces, steel surfaces, and bulk samples; (2) quick-look detectors for photoionization and ultraviolet; (3) multisample trapping module to trap and store vaporized contaminants in a manner suitable for subsequent detailed lab-based analyses

  2. Methods for simultaneous detection of the cyanotoxins BMAA, DABA, and anatoxin-a in environmental samples.

    Science.gov (United States)

    Al-Sammak, Maitham Ahmed; Hoagland, Kyle D; Snow, Daniel D; Cassada, David

    2013-12-15

    Blue-green algae, also known as cyanobacteria, can produce several different groups of toxins in the environment including hepatotoxins (microcystins), neurotoxic non-protein amino acids β-methylamino-l-alanine (BMAA), and 2,4-diaminobutyric (DABA), as well as the bicyclic amine alkaloid anatoxin-a. Few studies have addressed the methods necessary for an accurate determination of cyanotoxins in environmental samples, and none have been published that can detect these cyanotoxins together in a single sample. Cyanotoxins occur in a wide range of environmental samples including water, fish, and aquatic plant samples. Using polymeric cation exchange solid phase extraction (SPE) coupled with liquid chromatography and fluorescence detection (HPLC/FD), and liquid chromatography ion trap tandem mass spectrometry (LC/MS/MS), these compounds can for the first time be simultaneously quantified in a variety of environmental sample types. The extraction method for biological samples can distinguish bound and free cyanotoxins. Detection limits for water ranged from 5 to 7 μg/L using HPLC/FD, while detection limits for and LC/MS were in the range of 0.8-3.2 μg/L. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. [Detection of Cryptospordium spp. in environmental water samples by FTA-PCR].

    Science.gov (United States)

    Zhang, Xiao-Ping; Zhu, Qian; He, Yan-Yan; Jiang, Li; Jiang, Shou-Fu

    2011-02-01

    To establish a FTA-polymeras chain reaction (FTA-PCR) method in detection of Cryptospordium spp. in different sources of water. The semi automated immunomagnetic separation (IMS) of Cryptospordium oocysts in environmental water samples was performed firstly, and then genomic DNA of Cryptospordium oocysts was extracted by FTA filters disk. Oligonucleotide primers were designed based on the DNA fragment of the 18 S rRNA gene from C. parvum. Plate DNA was amplified with primers in PCR. The control DNA samples from Toxoplasma gondii,Sarcocystis suihominis, Echinococcus granulosus, and Clonorchis sinensis were amplified simultaneously. All PCR products were detected by agar electrophoresis dyed with ethidium bromide. The 446 bp fragment of DNA was detected in all samples of C. parvum, C. andersoni, and C. baileyi, while it was not detected in control groups in laboratory. No positive samples were found from 10 samples collected from tape water in 5 districts of Shanghai City by FTA-PCR. Nine positive samples were detected totally from 70 different environmental water samples, there were 0 out of 15 samples from the source of tape water, 2 out of 25 from the Huangpu River, 5 out of 15 from rivers around the animal farmers, 1 out of 9 from output water of contaminating water treatment factory, 1 out of 6 from the out gate of living contaminating water. The 446 bp fragment was detected from all the amplified positive water samples. FTA-PCR is an efficient method for gene detection of Cryptospordium oocysts, which could be used in detection of environmental water samples. The contamination degree of Cryptospordium oocysts in the river water around animal farms is high.

  4. Europa's surface radiation environment and considerations for in-situ sampling and biosignature detection

    Science.gov (United States)

    Nordheim, T.; Paranicas, C.; Hand, K. P.

    2017-12-01

    Jupiter's moon Europa is embedded deep within the Jovian magnetosphere and is thus exposed to bombardment by charged particles, from thermal plasma to more energetic particles at radiation belt energies. In particular, energetic charged particles are capable of affecting the uppermost layer of surface material on Europa, in some cases down to depths of several meters (Johnson et al., 2004; Paranicas et al., 2009, 2002). Examples of radiation-induced surface alteration include sputtering, radiolysis and grain sintering; processes that are capable of significantly altering the physical properties of surface material. Radiolysis of surface ices containing sulfur-bearing contaminants from Io has been invoked as a possible explanation for hydrated sulfuric acid detected on Europa's surface (Carlson et al., 2002, 1999) and radiolytic production of oxidants represents a potential source of energy for life that could reside within Europa's sub-surface ocean (Chyba, 2000; Hand et al., 2007; Johnson et al., 2003; Vance et al., 2016). Accurate knowledge of Europa's surface radiation environment is essential to the interpretation of space and Earth-based observations of Europa's surface and exosphere. Furthermore, future landed missions may seek to sample endogenic material emplaced on Europa's surface to investigate its chemical composition and to search for biosignatures contained within. Such material would likely be sampled from the shallow sub-surface, and thus, it becomes crucial to know to which degree this material is expected to have been radiation processed.Here we will present modeling results of energetic electron and proton bombardment of Europa's surface, including interactions between these particles and surface material. In addition, we will present predictions for biosignature destruction at different geographical locations and burial depths and discuss the implications of these results for surface sampling by future missions to Europa's surface.

  5. Estimation of the sensitivity of various environmental sampling methods for detection of Salmonella in duck flocks.

    Science.gov (United States)

    Arnold, Mark E; Mueller-Doblies, Doris; Gosling, Rebecca J; Martelli, Francesca; Davies, Robert H

    2015-01-01

    Reports of Salmonella in ducks in the UK currently rely upon voluntary submissions from the industry, and as there is no harmonized statutory monitoring and control programme, it is difficult to compare data from different years in order to evaluate any trends in Salmonella prevalence in relation to sampling methodology. Therefore, the aim of this project was to assess the sensitivity of a selection of environmental sampling methods, including the sampling of faeces, dust and water troughs or bowls for the detection of Salmonella in duck flocks, and a range of sampling methods were applied to 67 duck flocks. Bayesian methods in the absence of a gold standard were used to provide estimates of the sensitivity of each of the sampling methods relative to the within-flock prevalence. There was a large influence of the within-flock prevalence on the sensitivity of all sample types, with sensitivity reducing as the within-flock prevalence reduced. Boot swabs (individual and pool of four), swabs of faecally contaminated areas and whole house hand-held fabric swabs showed the overall highest sensitivity for low-prevalence flocks and are recommended for use to detect Salmonella in duck flocks. The sample type with the highest proportion positive was a pool of four hair nets used as boot swabs, but this was not the most sensitive sample for low-prevalence flocks. All the environmental sampling types (faeces swabs, litter pinches, drag swabs, water trough samples and dust) had higher sensitivity than individual faeces sampling. None of the methods consistently identified all the positive flocks, and at least 10 samples would be required for even the most sensitive method (pool of four boot swabs) to detect a 5% prevalence. The sampling of dust had a low sensitivity and is not recommended for ducks.

  6. Analytical Methodology for the Determination of Radium Isotopes in Environmental Samples

    International Nuclear Information System (INIS)

    2010-01-01

    Reliable, comparable and 'fit for purpose' results are an essential requirement for any decision based on analytical measurements. For the analyst, the availability of tested and validated analytical procedures is an extremely important tool for production of such analytical measurements. For maximum utility, such procedures should be comprehensive, clearly formulated, and readily available to both the analyst and the customer for reference. Since 2004, the environment programme of the IAEA has included activities aimed at the development of a set of procedures for the determination of radionuclides in terrestrial environmental samples. Measurements of radium isotopes are important for radiological and environmental protection, geochemical and geochronological investigations, hydrology, etc. The suite of isotopes creates and stimulates continuing interest in the development of new methods for determination of radium in various media. In this publication, the four most routinely used analytical methods for radium determination in biological and environmental samples, i.e. alpha spectrometry, gamma spectrometry, liquid scintillation spectrometry and mass spectrometry, are reviewed

  7. Computer system for environmental sample analysis and data storage and analysis

    International Nuclear Information System (INIS)

    Brauer, F.P.; Fager, J.E.

    1976-01-01

    A mini-computer based environmental sample analysis and data storage system has been developed. The system is used for analytical data acquisition, computation, storage of analytical results, and tabulation of selected or derived results for data analysis, interpretation and reporting. This paper discussed the structure, performance and applications of the system

  8. Reproducibility of measurement of the environmental carbon-14 samples prepared by the gel suspension method

    International Nuclear Information System (INIS)

    Ohura, Hirotaka; Wakabayashi, Genichiro; Nakamura, Kouji; Okai, Tomio; Matoba, Masaru; Kakiuchi, Hideki; Momoshima, Noriyuki; Kawamura, Hidehisa.

    1997-01-01

    Simple liquid scintillation counting technique for the assay of 14 C in the environment was developed. This technique was done by using gel suspension method, in which sample preparation is very simple and requires no special equipments. The reproducibility of this technique was considered and it was shown that the gel suspension method had enough reproducibility to monitor the environmental 14 C. (author)

  9. Analysis of trace uranium and plutonium in environmental water sample by ICP-MS

    International Nuclear Information System (INIS)

    Liu Xuemei

    2004-12-01

    The analysis of trace Uranium and Plutonium in environmental water is very important in the environment inspect. The preparation method of water samples are introduced and several common used method are compared. The analysis process and the calibration method with ICP-MS are discussed in detail considering present conditions. (author)

  10. Controlled dehydration of a biological sample using an alternative form of environmental SEM

    Czech Academy of Sciences Publication Activity Database

    Neděla, Vilém

    2010-01-01

    Roč. 237, č. 1 (2010), s. 7-11 ISSN 0022-2720 Institutional research plan: CEZ:AV0Z20650511 Keywords : biological sample * dehydration * environmental SEM * AQUASEM II * hydration system Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.872, year: 2010

  11. Determination of Technetium-99 in Environmental Samples by Solvent Extraction at Controlled Valence

    DEFF Research Database (Denmark)

    Chen, Q.J.; Aarkrog, A.; Dahlgaard, H.

    1989-01-01

    Distribution coefficients of technetium and ruthenium are determined under different conditions with CCl4, cyclohexanone, and 5% tri-isooctylamine (TIOA)/xylene. A method for analyzing 99Tc in environmental samples has been developed by solvent extraction in which the valences of technetium...

  12. Validation of dipslides as a tool for environmental sampling in a real-life hospital setting

    DEFF Research Database (Denmark)

    Ibfelt, T; Foged, Charlotte Bernhardt Laiho; Andersen, L P

    2014-01-01

    Environmental sampling in hospitals is becoming increasingly important because of the rise in nosocomial infections. In order to monitor and track these infections and optimize cleaning and disinfection, we need to be able to locate the fomites with the highest amount of microorganisms, but the o...

  13. A review of electro analytical determinations of some important elements (Zn, Se, As) in environmental samples

    International Nuclear Information System (INIS)

    Lichiang; James, B.D.; Magee, R.J.

    1991-01-01

    This review covers electro analytical methods reported in the literature for the determination of zinc, cadmium, selenium and arsenic in environmental and biological samples. A comprehensive survey of electro analytical techniques used for the determination of four important elements, i.e. zinc, cadmium, selenium and arsenic is reported herein with 322 references up to 1990. (Orig./A.B.)

  14. Self-absorption corrections for gamma ray spectral measurements of 210Pb in environmental samples

    International Nuclear Information System (INIS)

    Miller, K.M.

    1987-01-01

    Theoretical considerations and experimental data are used to demonstrate the basic behaviour of the self-absorption effect of a sample matrix in gamma ray spectrometry, particularly as it relates to the analysis of 210 Pb in environmental media. The results indicate that it may not be appropriate to apply the commonly used self-absorption function in all cases. (orig.)

  15. Fractionation of plutonium in environmental and bio-shielding concrete samples using dynamic sequential extraction

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin

    2010-01-01

    Fractionation of plutonium isotopes (238Pu, 239,240Pu) in environmental samples (i.e. soil and sediment) and bio-shielding concrete from decommissioning of nuclear reactor were carried out by dynamic sequential extraction using an on-line sequential injection (SI) system combined with a specially...

  16. Measuring environmental change in forest ecosystems by repeated soil sampling: A North American perspective

    Science.gov (United States)

    Gregory B. Lawrence; Ivan J. Fernandez; Daniel D. Richter; Donald S. Ross; Paul W. Hazlett; Scott W. Bailey; Rock Ouimet; Richard A. F. Warby; Arthur H. Johnson; Henry Lin; James M. Kaste; Andrew G. Lapenis; Timothy J. Sullivan

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest...

  17. Improved optimum condition for recovery and measurement of 210Po in environmental samples

    International Nuclear Information System (INIS)

    Zal Uyun Wan Mahmood; Norfaizal Mohamed; Nik Azlin Nik Ariffin; Abdul Kadir Ishak

    2012-01-01

    An improved laboratory technique for measurement of polonium-210( 210 Po) in environmental samples has been developed in Radiochemistry and Environmental Laboratory (RAS), Malaysian Nuclear Agency. To further improve this technique, a study with the objectives to determine the optimum conditions for 210 Po deposition and; evaluate the accuracy and precision results for the determination of 210 Po in environmental samples was carried-out. Polonium-210 which is an alpha emitter obtained in acidic solution through total digestion and dissolution of samples has been efficiently plated onto one side of the silver disc in the spontaneous plating process for measurement of its alpha activity. The optimum conditions for deposition of 210 Po were achieved using hydrochloric acid (HCl) media at acidity of 0.5 M with the presence of 1.0 gram hydroxyl ammonium chloride and the plating temperature at 90 degree Celsius. The plating was carried out in 80 ml HCl solution (0.5 M) for 4 hours. The recorded recoveries obtained using 209 Po tracers in the CRM IAEA-385 and environmental samples were 85 % - 98% whereby the efficiency of the new technique is a distinct advantage over the existing techniques. Therefore, optimization of deposition parameters is a prime importance to achieve accuracy and precision results as well as economy and time saving. (author)

  18. A simple and rapid cultural method for detection of Enterobacter sakazakii in environmental samples

    NARCIS (Netherlands)

    Guillaume-Gentil, O.; Sonnard, V.; Kandhai, M.C.; Marugg, J.; Joosten, H.

    2005-01-01

    A method was developed to detect and identify Enterobacter sakazakii in environmental samples. The method is based on selective enrichment at 45 ± 0.5°C in lauryl sulfate tryptose broth supplemented with 0.5 M NaCl and 10 mg/liter vancomycin (mLST) for 22 to 24 h followed by streaking on tryptone

  19. Repurposing environmental DNA samples: Detecting the western pearlshell (Margaritifera falcata) as a proof of concept

    Science.gov (United States)

    Joseph C. Dysthe; Torrey Rodgers; Thomas W. Franklin; Kellie J. Carim; Michael K. Young; Kevin S. McKelvey; Karen E. Mock; Michael K. Schwartz

    2018-01-01

    Information on the distribution of multiple species in a common landscape is fundamental to effective conservation and management. However, distribution data are expensive to obtain and often limited to high-profile species in a system. A recently developed technique, environmental DNA (eDNA) sampling, has been shown to be more sensitive than traditional detection...

  20. Martian Surface Boundary Layer Characterization: Enabling Environmental Data for Science, Engineering and Human Exploration

    Science.gov (United States)

    England, C.

    2000-01-01

    For human or large robotic exploration of Mars, engineering devices such as power sources will be utilized that interact closely with the Martian environment. Heat sources for power production, for example, will use the low ambient temperature for efficient heat rejection. The Martian ambient, however, is highly variable, and will have a first order influence on the efficiency and operation of all large-scale equipment. Diurnal changes in temperature, for example, can vary the theoretical efficiency of power production by 15% and affect the choice of equipment, working fluids, and operating parameters. As part of the Mars Exploration program, missions must acquire the environmental data needed for design, operation and maintenance of engineering equipment including the transportation devices. The information should focus on the variability of the environment, and on the differences among locations including latitudes, altitudes, and seasons. This paper outlines some of the WHY's, WHAT's and WHERE's of the needed data, as well as some examples of how this data will be used. Environmental data for engineering design should be considered a priority in Mars Exploration planning. The Mars Thermal Environment Radiator Characterization (MTERC), and Dust Accumulation and Removal Technology (DART) experiments planned for early Mars landers are examples of information needed for even small robotic missions. Large missions will require proportionately more accurate data that encompass larger samples of the Martian surface conditions. In achieving this goal, the Mars Exploration program will also acquire primary data needed for understanding Martian weather, surface evolution, and ground-atmosphere interrelationships.

  1. Lower-Cost, Relocatable Lunar Polar Lander and Lunar Surface Sample Return Probes

    Science.gov (United States)

    Amato, G. Michael; Garvin, James B.; Burt, I. Joseph; Karpati, Gabe

    2011-01-01

    Key science and exploration objectives of lunar robotic precursor missions can be achieved with the Lunar Explorer (LEx) low-cost, robotic surface mission concept described herein. Selected elements of the LEx concept can also be used to create a lunar surface sample return mission that we have called Boomerang

  2. Occurrence and behavior of butyltins in intertidal and shallow subtidal surface sediments of an estuarine beach under different sampling conditions

    Science.gov (United States)

    Santos, Dayana Moscardi dos; Sant'Anna, Bruno Sampaio; Sandron, Daniela Corsino; Cardoso de Souza, Sara; Cristale, Joyce; Marchi, Mary Rosa Rodrigues de; Turra, Alexander

    2010-07-01

    Contamination by butyltin compounds (BTs) has been reported in estuarine environments worldwide, with serious impacts on the biota of these areas. Considering that BTs can be degraded by varying environmental conditions such as incident light and salinity, the short-term variations in such factors may lead to inaccurate estimates of BTs concentrations in nature. Therefore, the present study aimed to evaluate the possibility that measurements of BTs in estuarine sediments are influenced by different sampling conditions, including period of the day (day or night), tidal zone (intertidal or subtidal), and tides (high or low). The study area is located on the Brazilian southeastern coast, São Vicente Estuary, at Pescadores Beach, where BT contamination was previously detected. Three replicate samples of surface sediment were collected randomly in each combination of period of the day, tidal zone, and tide condition, from three subareas along the beach, totaling 72 samples. BTs were analyzed by GC-PFPD using a tin filter and a VF-5 column, by means of a validated method. The concentrations of tributyltin (TBT), dibutyltin (DBT), and monobutyltin (MBT) ranged from undetectable to 161 ng Sn g -1 (d.w.). In most samples (71%), only MBT was quantifiable, whereas TBTs were measured in only 14, suggesting either an old contamination or rapid degradation processes. DBT was found in 27 samples, but could be quantified in only one. MBT concentrations did not differ significantly with time of day, zones, or tide conditions. DBT and TBT could not be compared under all these environmental conditions, because only a few samples were above the quantification limit. Pooled samples of TBT did not reveal any difference between day and night. These results indicated that, in assessing contamination by butyltin compounds, surface-sediment samples can be collected in any environmental conditions. However, the wide variation of BTs concentrations in the study area, i.e., over a very small

  3. Distribution of Heavy Metal Content Hg and Cr of Environmental Samples at Surabaya Area

    International Nuclear Information System (INIS)

    Agus Taftazani

    2007-01-01

    Determination of Hg and Cr content of Surabaya river and coastal environmental samples using Instrumental Neutron Activation Analysis (INAA) have been done. The environmental samples were water, sediment, Eichhornia crassipes (Mart) Solmms, Rhizophora stylosa, Johnius (Johnieops) borneensis fish, and Moolgarda delicate fish at 12 locations selected of Surabaya area. Dry powder of sediment and biotic samples and concentrate water samples was irradiated by neutron flux 1.05 x 10 11 n.cm -2 .det -1 during 12 hours. The analytical result showed that the concentration of the heavy metals of river water are smaller than Perda Surabaya City No. 02/2004 for the 4 th level water which are Hg (0.005 ppm) and Cr (1.000 ppm). All locations coastal water samples have Hg and Cr concentrations are higher than Kepmen LH No.51/2004 Hg (0.001 ppm) and Cr (0.005 ppm). The Hg concentration of fish samples have exceeded the threshold according to Kep. Dirjen POM No.03725/B/SK/VII/89 about the maximum concentration of metal pollution in food. The concentration of heavy metals in sediment, Eichhornia crassipes (Mart) Solmms and Rhizophora stylosa are not regulated, so then heavy metals pollution can not be referred to. The concentration of Hg and Cr elements of water samples are smaller than that of biotic and sediment samples. The distribution factor (F d ) is bigger than bioaccumulation factor (F b ). (author)

  4. Electrodeposition as an alternate method for preparation of environmental samples for iodide by AMS

    Energy Technology Data Exchange (ETDEWEB)

    Adamic, M.L., E-mail: Mary.Adamic@inl.gov [Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83402 (United States); Lister, T.E.; Dufek, E.J.; Jenson, D.D.; Olson, J.E. [Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83402 (United States); Vockenhuber, C. [Laboratory of Ion Beam Physics, ETH Zurich, Otto-Stern-Weg 5, 8093 Zurich (Switzerland); Watrous, M.G. [Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83402 (United States)

    2015-10-15

    This paper presents an evaluation of an alternate method for preparing environmental samples for {sup 129}I analysis by accelerator mass spectrometry (AMS) at Idaho National Laboratory. The optimal sample preparation method is characterized by ease of preparation, capability of processing very small quantities of iodide, and ease of loading into a cathode. Electrodeposition of iodide on a silver wire was evaluated using these criteria. This study indicates that the electrochemically-formed silver iodide deposits produce ion currents similar to those from precipitated silver iodide for the same sample mass. Precipitated silver iodide samples are usually mixed with niobium or silver powder prior to loading in a cathode. Using electrodeposition, the silver is already mixed with the sample and can simply be picked up with tweezers, placed in the sample die, and pressed into a cathode. The major advantage of this method is that the silver wire/electrodeposited silver iodide is much easier to load into a cathode.

  5. Electrodeposition as an alternate method for preparation of environmental samples for iodide by AMS

    International Nuclear Information System (INIS)

    Adamic, M.L.; Lister, T.E.; Dufek, E.J.; Jenson, D.D.; Olson, J.E.; Vockenhuber, C.; Watrous, M.G.

    2015-01-01

    This paper presents an evaluation of an alternate method for preparing environmental samples for "1"2"9I analysis by accelerator mass spectrometry (AMS) at Idaho National Laboratory. The optimal sample preparation method is characterized by ease of preparation, capability of processing very small quantities of iodide, and ease of loading into a cathode. Electrodeposition of iodide on a silver wire was evaluated using these criteria. This study indicates that the electrochemically-formed silver iodide deposits produce ion currents similar to those from precipitated silver iodide for the same sample mass. Precipitated silver iodide samples are usually mixed with niobium or silver powder prior to loading in a cathode. Using electrodeposition, the silver is already mixed with the sample and can simply be picked up with tweezers, placed in the sample die, and pressed into a cathode. The major advantage of this method is that the silver wire/electrodeposited silver iodide is much easier to load into a cathode.

  6. Current status of JAERI program on development of ultra-trace-analytical technology for safeguards environmental samples

    International Nuclear Information System (INIS)

    Adachi, T.; Usuda, S.; Watanabe, K.

    2001-01-01

    is, therefore, studying on the selective recovery of uranium particles from the swipe samples. Otherwise, alternative swipe materials with less uranium blank would be preferable. The analytical technology for individual particles in the environmental samples is an important issue to develop. Works are continued with total reflection X-ray fluorescence spectrometry (TXRF) for screening, electron-probe microanalysis (EPMA) for elemental composition and morphology of each particle, and secondary ion mass spectrometry (SIMS) for isotopic ratio measurement. A special mount made of glassy carbon was designed in order that the mount could be commonly used among the three apparatuses. The detection limit of uranium in particle screening by TXRF was achieved to 0.4 ng. By combination of TXRF, EPMA and SIMS, the throughput for analysis on uranium particle of 1 μm was one swipe per day, which is to be increased by improvement of the technique for particle mapping. The place of the R and D work will be moved to the CLEAR facility, the construction of which was completed in December 2000. The facility includes clean rooms (215 m 2 ) with cleanliness class 100 for chemical sample treatment and those (480 m 2 ) with class 1,000 and 10,000 for analytical operation, sample storage, etc. The facility performance tests were carried out prior to the installation of analytical equipment, which gave the satisfactory results, e.g., class 10 on working surfaces of clean hoods and benches. The full operation of the facility is scheduled for June 2001. The first phase of the program continues until March 2003. During this period, fundamental technology for ultra-trace analysis for uranium and plutonium will be established with sufficient sensitivity and accuracy for the environmental sample analysis. JAERI will contribute to the strengthened safeguards system of IAEA by joining the community of Network Analytical Laboratories as a first member from the Asian area, as well as contribute to

  7. Classification of Surface and Deep Soil Samples Using Linear Discriminant Analysis

    International Nuclear Information System (INIS)

    Wasim, M.; Ali, M.; Daud, M.

    2015-01-01

    A statistical analysis was made of the activity concentrations measured in surface and deep soil samples for natural and anthropogenic gamma-emitting radionuclides. Soil samples were obtained from 48 different locations in Gilgit, Pakistan covering about 50 km/sup 2/ areas at an average altitude of 1550 m above sea level. From each location two samples were collected: one from the top soil (2-6 cm) and another from a depth of 6-10 cm. Four radionuclides including /sup 226/Ra, /sup 232/Th, /sup 40/K and /sup 137/Cs were quantified. The data was analyzed using t-test to find out activity concentration difference between the surface and depth samples. At the surface, the median activity concentrations were 23.7, 29.1, 4.6 and 115 Bq kg/sup -1/ for 226Ra, 232Th, 137Cs and 40K respectively. For the same radionuclides, the activity concentrations were respectively 25.5, 26.2, 2.9 and 191 Bq kg/sup -1/ for the depth samples. Principal component analysis (PCA) was applied to explore patterns within the data. A positive significant correlation was observed between the radionuclides /sup 226/Ra and /sup 232/Th. The data from PCA was further utilized in linear discriminant analysis (LDA) for the classification of surface and depth samples. LDA classified surface and depth samples with good predictability. (author)

  8. Data Validation Package - June 2015 Groundwater and Surface Water Sampling at the Green River, Utah, Disposal Site

    Energy Technology Data Exchange (ETDEWEB)

    Linard, Joshua [USDOE Office of Legacy Management, Washington, DC (United States); Price, Jeffrey [Navarro Research and Engineering, Inc., Las Vegas, NV (United States)

    2015-08-01

    Groundwater samples were collected during the 2015 sampling event from point-of-compliance (POC) wells 0171, 0173, 0176, 0179, 0181, and 0813 to monitor the disposition of contaminants in the middle sandstone unit of the Cedar Mountain Formation. Groundwater samples also were collected from alluvium monitoring wells 0188, 0189, 0192, 0194, and 0707, and basal sandstone monitoring wells 0182, 0184, 0185, and 0588 as a best management practice. Surface locations 0846 and 0847 were sampled to monitor for degradation of water quality in the backwater area of Brown’s Wash and in the Green River immediately downstream of Brown’s Wash. The Green River location 0801 is upstream from the site and is sampled to determine background-threshold values (BTVs). Sampling and analyses were conducted as specified in Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and- analysis-plan-us-department-energy-office-legacy-management-sites). Water levels were measured at each sampled well. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. All six POC wells are completed in the middle sandstone unit of the Cedar Mountain Formation and are monitored to measure contaminant concentrations for comparison to proposed alternate concentration limits (ACLs), as provided in Table 1. Contaminant concentrations in the POC wells remain below their respective ACLs.

  9. Determination of radiocesium in environmental water samples using copper ferro(II)cyanide and sodium tetraphenylborate

    International Nuclear Information System (INIS)

    Popov, L.; Kuleff, I.; Djingova, R.

    2006-01-01

    A procedure for the radiochemical separation and radiochemical purification of radiocesium ( 134 Cs and 137 Cs) in bulk environmental water samples is proposed. Radiocesium was removed from the water by cation-exchange with copper ferro(II)cyanide and was purified by precipitation with sodium tetraphenylborate. The influence of the concentration of potassium in the water sample on the chemical yield was investigated. The validation of the proposed method was carried out by analyzing reference materials. The application of the method was demonstrated with the determination of the concentration of radiocesium in water samples from rivers around NPP 'Kozloduy', Bulgaria, Danube and Ogosta. (author)

  10. Quantification of uncertainty in gamma spectrometric analysis of food and environmental samples

    International Nuclear Information System (INIS)

    Yii Mei Wo; Zaharudin Ahmad; Norfaizal Mohamed

    2005-01-01

    Gamma Spectrometry is widely used to determine the activity of gamma-ray emitter radionuclide inside a sample. Reporting the activity of the measurement for a sample should not be a single value only but it shall be associated with a reasonable uncertainty value since disintegration of radionuclide is a random/spontaneous process. This paper will focus on how the uncertainty was estimated, quantified and calculated, when measuring the activity of Cs-134 and Cs-137 in food and Ra-226, Ra-228 and K-40 in the environmental samples. (Author)

  11. Design of a Clean Room for Quality Control of an Environmental Sampling in KINAC

    International Nuclear Information System (INIS)

    Yoon, Jongho; Ahn, Gil Hoon; Seo, Hana; Han, Kitek; Park, Il Jin

    2014-01-01

    The objective of environmental sampling and analysis for safeguards is to characterize the nuclear materials handled and the activities conducted at the specific locations. The KINAC is responsible for the conclusions drawn from the analytical results provided by the analytical laboratories. To assure the KINAC of the continuity of the quality of the analytical results provided by the laboratories, the KINAC will implement a quality control(QC) programme. One of the QC programme is to prepare QC samples. The establishment of a clean room is needed to handle QC samples due to stringent control of contamination. The KINAC designed a clean facility with cleanliness of ISO Class 6, the Clean Room for Estimation and Assay of trace Nuclear materials(CREAN) to meet conflicting requirements of a clean room and for handling of nuclear materials according to Korean laws. The clean room will be expected to acquire of a radiation safety license under these conditions in this year and continue to improve it. The construction of the CREAN facility will be completed by the middle of 2015. In terms of QC programme, the establishment of a clean room is essential and will be not only very helpful for setting of quality control system for the national environmental sampling programme but also be applied for the environmental sample analysis techniques to the nuclear forensics

  12. Determination of 36Cl in environmental samples collected in the JCO by AMS

    International Nuclear Information System (INIS)

    Seki, R.; Tsukuba Univ., Ibaraki; Arai, D.; Nagashima, Y.; Takahashi, T.; Matsuhiro, T.; Imanaka, T.

    2003-01-01

    Long-lived chlorine, 36 Cl (T 1/2 = 301,000 y) in environmental samples has been measured by the AMS system installed in Tandem Accelerator Center, University of Tsukuba. A tri-carbon-molecular 12 C 3 - pilot beam method is used to stabilize the terminal voltage of the tandem. A small amount of pure carbon graphite is well mixed into a AgCl target material for creating Cl - and 12 C 3 - in the ion source. A 36 S isobaric interference in the system is eliminated to determine 36 Cl in environmental samples by chemical procedure. Some samples containing chlorine such as soil, chemical reagents and table salt have been collected in the JCO criticality accident site and analyzed to detect neutron-induced 36 Cl. The experimental result has been compared with a theoretical calculation. (author)

  13. Isotope Enrichment Detection by Laser Ablation - Laser Absorption Spectrometry: Automated Environmental Sampling and Laser-Based Analysis for HEU Detection

    International Nuclear Information System (INIS)

    Anheier, Norman C.; Bushaw, Bruce A.

    2010-01-01

    The global expansion of nuclear power, and consequently the uranium enrichment industry, requires the development of new safeguards technology to mitigate proliferation risks. Current enrichment monitoring instruments exist that provide only yes/no detection of highly enriched uranium (HEU) production. More accurate accountancy measurements are typically restricted to gamma-ray and weight measurements taken in cylinder storage yards. Analysis of environmental and cylinder content samples have much higher effectiveness, but this approach requires onsite sampling, shipping, and time-consuming laboratory analysis and reporting. Given that large modern gaseous centrifuge enrichment plants (GCEPs) can quickly produce a significant quantity (SQ ) of HEU, these limitations in verification suggest the need for more timely detection of potential facility misuse. The Pacific Northwest National Laboratory (PNNL) is developing an unattended safeguards instrument concept, combining continuous aerosol particulate collection with uranium isotope assay, to provide timely analysis of enrichment levels within low enriched uranium facilities. This approach is based on laser vaporization of aerosol particulate samples, followed by wavelength tuned laser diode spectroscopy to characterize the uranium isotopic ratio through subtle differences in atomic absorption wavelengths. Environmental sampling (ES) media from an integrated aerosol collector is introduced into a small, reduced pressure chamber, where a focused pulsed laser vaporizes material from a 10 to 20-(micro)m diameter spot of the surface of the sampling media. The plume of ejected material begins as high-temperature plasma that yields ions and atoms, as well as molecules and molecular ions. We concentrate on the plume of atomic vapor that remains after the plasma has expanded and then cooled by the surrounding cover gas. Tunable diode lasers are directed through this plume and each isotope is detected by monitoring absorbance

  14. A sensitive analytical procedure for monitoring acrylamide in environmental water samples by offline SPE-UPLC/MS/MS.

    Science.gov (United States)

    Togola, Anne; Coureau, Charlotte; Guezennec, Anne-Gwenaëlle; Touzé, Solène

    2015-05-01

    The presence of acrylamide in natural systems is of concern from both environmental and health points of view. We developed an accurate and robust analytical procedure (offline solid phase extraction combined with UPLC/MS/MS) with a limit of quantification (20 ng L(-1)) compatible with toxicity threshold values. The optimized (considering the nature of extraction phases, sampling volumes, and solvent of elution) solid phase extraction (SPE) was validated according to ISO Standard ISO/IEC 17025 on groundwater, surface water, and industrial process water samples. Acrylamide is highly polar, which induces a high variability during the SPE step, therefore requiring the use of C(13)-labeled acrylamide as an internal standard to guarantee the accuracy and robustness of the method (uncertainty about 25 % (k = 2) at limit of quantification level). The specificity of the method and the stability of acrylamide were studied for these environmental media, and it was shown that the method is suitable for measuring acrylamide in environmental studies.

  15. MODELING THE INTERACTION OF AGROCHEMICALS WITH ENVIRONMENTAL SURFACES

    Science.gov (United States)

    The interactions between agrochemicals and organo-mineral surfaces were studied using molecular mechanical conformational calculations and molecular dynamics simulations. Atrazine (2-chloro-4-ethylamino-6-isopropylamino-s-triazine), 2,4-D (1, 2-dichlorophenoxyacetic acid), and DD...

  16. Removal of impurities from environmental water samples for tritium measurement by means of liquid scintillation counter

    International Nuclear Information System (INIS)

    Sakuma, Yoichi; Noda, Mitsuyasu

    2000-01-01

    Tritium concentration in environmental water samples is usually measured by means of liquid scintillation counting. Before the counting distillation operation is necessarily required to remove impurities, which have possibility of bad influence on the measurement, from the samples. But the operation usually takes long time and it is also troublesome. If you could simplify the purification process, you would be much easily able to measure it. Then, we have studied the probability of replacement the process by filtration aiming to simplify the procedure. We prepared several environmental water samples and also several water samples added quenching materials. These samples were purified by means of the distillation and the filtration and the impurities in them were examined. The purified samples were mixed with scintillation cocktail and the tritium concentration was measured. We added small amount of tritium in the same samples and investigated their scintillation spectra and their ESCR values in order to compare the two purification methods. Two kinds of filters were used for the filtration: 0.45 μm and 0.1 μm pore sized membrane filters. The liquid scintillation counter was LB-3 produced by Aloka Co. and Ltd. The scintillation cocktail was Ultima Gold LLT made by Packard Instrument Co and Ltd. The vial was Polyvial 145 LSD made by Zinsser Analytic Co. and Ltd. As the result, there was no significant difference between the two purification methods then the filtration method is feasible instead of the distillation. (author)

  17. Intact preservation of environmental samples by freezing under an alternating magnetic field.

    Science.gov (United States)

    Morono, Yuki; Terada, Takeshi; Yamamoto, Yuhji; Xiao, Nan; Hirose, Takehiro; Sugeno, Masaya; Ohwada, Norio; Inagaki, Fumio

    2015-04-01

    The study of environmental samples requires a preservation system that stabilizes the sample structure, including cells and biomolecules. To address this fundamental issue, we tested the cell alive system (CAS)-freezing technique for subseafloor sediment core samples. In the CAS-freezing technique, an alternating magnetic field is applied during the freezing process to produce vibration of water molecules and achieve a stable, super-cooled liquid phase. Upon further cooling, the temperature decreases further, achieving a uniform freezing of sample with minimal ice crystal formation. In this study, samples were preserved using the CAS and conventional freezing techniques at 4, -20, -80 and -196 (liquid nitrogen) °C. After 6 months of storage, microbial cell counts by conventional freezing significantly decreased (down to 10.7% of initial), whereas that by CAS-freezing resulted in minimal. When Escherichia coli cells were tested under the same freezing conditions and storage for 2.5 months, CAS-frozen E. coli cells showed higher viability than the other conditions. In addition, an alternating magnetic field does not impact on the direction of remanent magnetization in sediment core samples, although slight partial demagnetization in intensity due to freezing was observed. Consequently, our data indicate that the CAS technique is highly useful for the preservation of environmental samples. © 2014 Society for Applied Microbiology and John Wiley & Sons Ltd.

  18. Influence of short-term sampling parameters on the uncertainty of the Lden environmental noise indicator

    International Nuclear Information System (INIS)

    Mateus, M; Carrilho, J Dias; Da Silva, M Gameiro

    2015-01-01

    The present study deals with the influence of the sampling parameters on the uncertainty of noise equivalent level in environmental noise measurements. The study has been carried out through the test of different sampling strategies doing resampling trials over continuous monitoring noise files obtained previously in an urban location in the city of Coimbra, in Portugal. On short term measurements, not only the duration of the sampling episodes but also its number have influence on the uncertainty of the result. This influence is higher for the time periods where sound levels suffer a greater variation, such as during the night period. In this period, in case both parameters (duration and number of sampling episodes) are not carefully selected, the uncertainty level can reach too high values contributing to a loss of precision of the measurements. With the obtained data it was investigated the sampling parameters influence on the long term noise indicator uncertainty, calculated according the Draft 1st CD ISO 1996-2:2012 proposed method. It has been verified that this method allows the possibility of defining a general methodology which enables the setting of the parameters once the precision level is fixed. For the three reference periods defined for environmental noise (day, evening and night), it was possible to derive a two variable power law representing the uncertainty of the determined values as a function of the two sampling parameters: duration of sampling episode and number of episodes

  19. Laser gas assisted texturing and formation of nitride and oxynitride compounds on alumina surface: Surface response to environmental dust

    Science.gov (United States)

    Yilbas, B. S.; Ali, H.; Al-Sharafi, A.; Al-Aqeeli, N.

    2018-03-01

    Laser gas assisted texturing of alumina surface is carried out, and formation of nitride and oxynitride compounds in the surface vicinity is examined. The laser parameters are selected to create the surface topology consisting of micro/nano pillars with minimum defect sites including micro-cracks, voids and large size cavities. Morphological and hydrophobic characteristics of the textured surface are examined using the analytical tools. The characteristics of the environmental dust and its influence on the laser textured surface are studied while mimicking the local humid air ambient. Adhesion of the dry mud on the laser textured surface is assessed through the measurement of the tangential force, which is required to remove the dry mud from the surface. It is found that laser texturing gives rise to micro/nano pillars topology and the formation of AlN and AlON compounds in the surface vicinity. This, in turn, lowers the free energy of the textured surface and enhances the hydrophobicity of the surface. The liquid solution resulted from the dissolution of alkaline and alkaline earth metals of the dust particles in water condensate forms locally scattered liquid islands at the interface of mud and textured surface. The dried liquid solution at the interface increases the dry mud adhesion on the textured surface. Some dry mud residues remain on the textured surface after the dry mud is removed by a pressurized desalinated water jet.

  20. A Portable Immunoassay Platform for Multiplexed Detection of Biotoxins in Clinical and Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Chung-Yan [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Piccini, Matthew Ernest [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Cepheid, Sunnyvale, CA (United States); Schaff, Ulrich Y. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Sandstone Diagnostics, Livermore, CA (United States); Stanker, Larry H. [US Dept. of Agriculture, Albany, CA (United States). Western Regional Research Center, Foodborne Contaminants Research Unit; Cheng, Luisa W. [US Dept. of Agriculture, Albany, CA (United States). Western Regional Research Center, Foodborne Contaminants Research Unit; Ravichandran, Easwaran [Univ. of Massachusetts, Dartmouth, MA (United States); Singh, Bal-Ram [Univ. of Massachusetts, Dartmouth, MA (United States); Sommer, Greg J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Sandstone Diagnostics, Livermore, CA (United States); Singh, Anup K. [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2015-01-01

    Multiple cases of attempted bioterrorism events using biotoxins have highlighted the urgent need for tools capable of rapid screening of suspect samples in the field (e.g., mailroom and public events). We present a portable microfluidic device capable of analyzing environmental (e.g., white powder), food (e.g., milk) and clinical (e.g., blood) samples for multiplexed detection of biotoxins. The device is rapid (<15-30 min sample-to-answer), sensitive (< 0.08 pg/mL detection limit for botulinum toxin), multiplexed (up to 64 parallel assays) and capable of analyzing small volume samples (< 20 μL total sample input). The immunoassay approach (SpinDx) is based on binding of toxins in a sample to antibody-laden capture particles followed by sedimentation of particles through a density-media in a microfluidic disk and quantification using a laser-induced fluorescence detector. A direct, blinded comparison with a gold standard ELISA revealed a 5-fold more sensitive detection limit for botulinum toxin while requiring 250-fold less sample volume and a 30 minute assay time with a near unity correlation. A key advantage of the technique is its compatibility with a variety of sample matrices with no additional sample preparation required. Ultrasensitive quantification has been demonstrated from direct analysis of multiple clinical, environmental and food samples, including white powder, whole blood, saliva, salad dressing, whole milk, peanut butter, half and half, honey, and canned meat. We believe that this device can met an urgent need in screening both potentially exposed people as well as suspicious samples in mail-rooms, airports, public sporting venues and emergency rooms. The general-purpose immunodiagnostics device can also find applications in screening of infectious and systemic diseases or serve as a lab device for conducting rapid immunoassays.

  1. An Optimized Method for Quantification of Pathogenic Leptospira in Environmental Water Samples.

    Science.gov (United States)

    Riediger, Irina N; Hoffmaster, Alex R; Casanovas-Massana, Arnau; Biondo, Alexander W; Ko, Albert I; Stoddard, Robyn A

    2016-01-01

    Leptospirosis is a zoonotic disease usually acquired by contact with water contaminated with urine of infected animals. However, few molecular methods have been used to monitor or quantify pathogenic Leptospira in environmental water samples. Here we optimized a DNA extraction method for the quantification of leptospires using a previously described Taqman-based qPCR method targeting lipL32, a gene unique to and highly conserved in pathogenic Leptospira. QIAamp DNA mini, MO BIO PowerWater DNA and PowerSoil DNA Isolation kits were evaluated to extract DNA from sewage, pond, river and ultrapure water samples spiked with leptospires. Performance of each kit varied with sample type. Sample processing methods were further evaluated and optimized using the PowerSoil DNA kit due to its performance on turbid water samples and reproducibility. Centrifugation speeds, water volumes and use of Escherichia coli as a carrier were compared to improve DNA recovery. All matrices showed a strong linearity in a range of concentrations from 106 to 10° leptospires/mL and lower limits of detection ranging from Leptospira in environmental waters (river, pond and sewage) which consists of the concentration of 40 mL samples by centrifugation at 15,000×g for 20 minutes at 4°C, followed by DNA extraction with the PowerSoil DNA Isolation kit. Although the method described herein needs to be validated in environmental studies, it potentially provides the opportunity for effective, timely and sensitive assessment of environmental leptospiral burden.

  2. Automated image analysis for quantitative fluorescence in situ hybridization with environmental samples.

    Science.gov (United States)

    Zhou, Zhi; Pons, Marie Noëlle; Raskin, Lutgarde; Zilles, Julie L

    2007-05-01

    When fluorescence in situ hybridization (FISH) analyses are performed with complex environmental samples, difficulties related to the presence of microbial cell aggregates and nonuniform background fluorescence are often encountered. The objective of this study was to develop a robust and automated quantitative FISH method for complex environmental samples, such as manure and soil. The method and duration of sample dispersion were optimized to reduce the interference of cell aggregates. An automated image analysis program that detects cells from 4',6'-diamidino-2-phenylindole (DAPI) micrographs and extracts the maximum and mean fluorescence intensities for each cell from corresponding FISH images was developed with the software Visilog. Intensity thresholds were not consistent even for duplicate analyses, so alternative ways of classifying signals were investigated. In the resulting method, the intensity data were divided into clusters using fuzzy c-means clustering, and the resulting clusters were classified as target (positive) or nontarget (negative). A manual quality control confirmed this classification. With this method, 50.4, 72.1, and 64.9% of the cells in two swine manure samples and one soil sample, respectively, were positive as determined with a 16S rRNA-targeted bacterial probe (S-D-Bact-0338-a-A-18). Manual counting resulted in corresponding values of 52.3, 70.6, and 61.5%, respectively. In two swine manure samples and one soil sample 21.6, 12.3, and 2.5% of the cells were positive with an archaeal probe (S-D-Arch-0915-a-A-20), respectively. Manual counting resulted in corresponding values of 22.4, 14.0, and 2.9%, respectively. This automated method should facilitate quantitative analysis of FISH images for a variety of complex environmental samples.

  3. Operable Unit 3-13, Group 3, Other Surface Soils (Phase II) Field Sampling Plan

    Energy Technology Data Exchange (ETDEWEB)

    G. L. Schwendiman

    2006-07-27

    This Field Sampling Plan describes the Operable Unit 3-13, Group 3, Other Surface Soils, Phase II remediation field sampling activities to be performed at the Idaho Nuclear Technology and Engineering Center located within the Idaho National Laboratory Site. Sampling activities described in this plan support characterization sampling of new sites, real-time soil spectroscopy during excavation, and confirmation sampling that verifies that the remedial action objectives and remediation goals presented in the Final Record of Decision for Idaho Nuclear Technology and Engineering Center, Operable Unit 3-13 have been met.

  4. May 2013 Groundwater and Surface Water Sampling at the Rio Blanco, Colorado, Site (Data Validation Package)

    Energy Technology Data Exchange (ETDEWEB)

    Hutton, Rick [S.M. Stoller Corporation, Broomfield, CO (United States)

    2013-10-01

    Annual sampling was conducted at the Rio Blanco, Colorado, site for the Long-Term Hydrologic Monitoring Program May 14-16, 2013, to monitor groundwater and surface water for potential radionuclide contamination. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for the U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). A duplicate sample was collected from location CER #1 Black Sulphur. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry and for tritium using the conventional and enrichment methods.

  5. A software for radioactivity measurement of Ra, Th and K in environmental samples

    International Nuclear Information System (INIS)

    Miao Zhengqiang; Bao Min; Chang Yongfu

    2004-01-01

    Radio nuclides of soil, rock, construction material, and almost everything around us. There is growing concern about environmental radioactivity from both scientists and public from an institutional or a common point of view. The regulation and standard on evaluating radioactivity of environmental samples have been issued recently by the authorities. We have developed special purpose Gamma spectra analysis software named ErSpec. The software can effectively process and analyze Gamma spectra measured by a NaI(T1) spectrometry, and can give a relatively precise results of radioactivity of 226 Ra, 232 Th and 40 K in environmental samples. The main functions of ErSpec include, processing and analyzing Gamma spectra, displaying some useful information for users, generating report, managing user's priority, logging user's manipulation, etc. Because environmental samples usually have low radioactivity and have complex measurement conditions, relative method is employed in ErSpec, and Channel-by-Channel Least-Squared Estimation is adopted as spectra analyzing method. The arithmetic make use of information extracted from data of hundreds of channels, then give a rather good result. In ErSpec, by using external call of MatLAB Math Lib in Visual C++, accuracy and speed of calculation and robustness of software are improved distinctly. Object-Oriented Programming Method and ActiveX techniques are also employed in software designing and coding stage. (authors)

  6. Radiochemistry methods in DOE Methods for Evaluating Environmental and Waste Management Samples: Addressing new challenges

    International Nuclear Information System (INIS)

    Fadeff, S.K.; Goheen, S.C.; Riley, R.G.

    1994-01-01

    Radiochemistry methods in Department of Energy Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) add to the repertoire of other standard methods in support of U.S. Department of Energy environmental restoration and waste management (DOE/EM) radiochemical characterization activities. Current standard sources of radiochemistry methods are not always applicable for evaluating DOE/EM samples. Examples of current sources include those provided by the US Environmental Protection Agency, the American Society for Testing and Materials, Standard Methods for the Examination of Water and Wastewater, and Environmental Measurements Laboratory Procedures Manual (HASL-300). The applicability of these methods is generally limited to specific matrices (usually water), low-level radioactive samples, and a limited number of analytes. DOE Methods complements these current standard methods by addressing the complexities of EM characterization needs. The process for determining DOE/EM radiochemistry characterization needs is discussed. In this context of DOE/EM needs, the applicability of other sources of standard radiochemistry methods is defined, and gaps in methodology are identified. Current methods in DOE Methods and the EM characterization needs they address are discussed. Sources of new methods and the methods incorporation process are discussed. The means for individuals to participate in (1) identification of DOE/EM needs, (2) the methods incorporation process, and (3) submission of new methods are identified

  7. Surface Environmental Surveillance Project: Locations Manual Volume 1 – Air and Water Volume 2 – Farm Products, Soil & Vegetation, and Wildlife

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, Brad G.; Patton, Gregory W.; Stegen, Amanda; Poston, Ted M.

    2009-01-01

    This report describes all environmental monitoring locations associated with the Surface Environmental Surveillance Project. Environmental surveillance of the Hanford site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 450.1, Environmental Protection Program, and DOE Order 5400.5, Radiation Protection of the Public and the Environment. The environmental surveillance sampling design is described in the Hanford Site Environmental Monitoring Plan, United States Department of Energy, Richland Operation Office (DOE/RL-91-50). This document contains the locations of sites used to collect samples for the Surface Environmental Surveillance Project (SESP). Each section includes directions, maps, and pictures of the locations. A general knowledge of roads and highways on and around the Hanford Site is necessary to successfully use this manual. Supplemental information (Maps, Gazetteer, etc.) may be necessary if user is unfamiliar with local routes. The SESP is a multimedia environmental surveillance effort to measure the concentrations of radionuclides and chemicals in environmental media to demonstrate compliance with applicable environmental quality standards and public exposure limits, and assessing environmental impacts. Project personnel annually collect selected samples of ambient air, surface water, agricultural products, fish, wildlife, and sediments. Soil and vegetation samples are collected approximately every 5 years. Analytical capabilities include the measurement of radionuclides at very low environmental concentrations and, in selected media, nonradiological chemicals including metals, anions, volatile organic compounds, and total organic carbon.

  8. Environmental assessment of coastal surface sediments at Tarut Island, Arabian Gulf (Saudi Arabia)

    International Nuclear Information System (INIS)

    Youssef, Mohamed; El-Sorogy, Abdelbaset; Al Kahtany, Khaled; Al Otiaby, Naif

    2015-01-01

    Highlights: • The present work deal with the environmental assessment of Tarut Island Coastal area. • Thirty eight surface sediments samples have been chemically analyzed. • Thirteen major and trace metals have been recorded. • The area of study is highly polluted with Arsenic and Mercury. - Abstract: Thirty eight surface sediments samples have been collected in the area around Tarut Island, Saudi Arabian Gulf to determine the spatial distribution of metals, and to assess the magnitude of pollution. Total concentrations of Fe, Mn, As, B, Cd, Co, Cr, Cu, Hg, Mo, Pb, Se, and Zn in the sediments were measured using ICP-MS (Inductively Coupled Plasma-Mass Spectrometer). Nature of sediments and heavy metals distribution reflect marked changes in lithology, biological activities in Tarut bay. Very high arsenic concentrations were reported in all studied locations from Tarut Island. The concentrations of Mercury are generally high comparing to the reported values from the Gulf of Oman, Red Sea. The concentrations of As and Hg exceeded the wet threshold safety values (MEC, PEC) indicating possible As and Hg contamination. Dredging and land filling, sewage, and oil pollution are the most important sources of pollution in the study area

  9. Laser-induced breakdown spectroscopy for detection of heavy metals in environmental samples

    Science.gov (United States)

    Wisbrun, Richard W.; Schechter, Israel; Niessner, Reinhard; Schroeder, Hartmut

    1993-03-01

    The application of LIBS technology as a sensor for heavy metals in solid environmental samples has been studied. This specific application introduces some new problems in the LIBS analysis. Some of them are related to the particular distribution of contaminants in the grained samples. Other problems are related to mechanical properties of the samples and to general matrix effects, like the water and organic fibers content of the sample. An attempt has been made to optimize the experimental set-up for the various involved parameters. The understanding of these factors has enabled the adjustment of the technique to the substrates of interest. The special importance of the grain size and of the laser-induced aerosol production is pointed out. Calibration plots for the analysis of heavy metals in diverse sand and soil samples have been carried out. The detection limits are shown to be usually below the recent regulation restricted concentrations.

  10. A radiochemical procedure for the determination of Po-210 in environmental samples

    International Nuclear Information System (INIS)

    Godoy, J.M.; Schuettelkopf, H.

    1980-07-01

    A radiochemical procedure for the determination of Po-210 in environmental samples was developed. Soil, sediments, filter materials, plants, water and food samples can be analyzed for Po-210. Wet ashing is achieved with HNO 3 + H 2 O 2 or HCl + HNO 3 . To separate disturbing substances, a coprecipitation with Te is used for sample materials containing silica. Po-210 deposition from HCl solution on Ag platelets with other sample materials is possible directly. Deposited Po-210 is counted by α-spectrometry. For chemical yield determination Po-208 is added, yields range between 60% and 100%. A lower detection limit of about 0,002 pCi Po-210/sample is achievable. (orig./HP) [de

  11. Effects of holding time and measurement error on culturing Legionella in environmental water samples.

    Science.gov (United States)

    Flanders, W Dana; Kirkland, Kimberly H; Shelton, Brian G

    2014-10-01

    Outbreaks of Legionnaires' disease require environmental testing of water samples from potentially implicated building water systems to identify the source of exposure. A previous study reports a large impact on Legionella sample results due to shipping and delays in sample processing. Specifically, this same study, without accounting for measurement error, reports more than half of shipped samples tested had Legionella levels that arbitrarily changed up or down by one or more logs, and the authors attribute this result to shipping time. Accordingly, we conducted a study to determine the effects of sample holding/shipping time on Legionella sample results while taking into account measurement error, which has previously not been addressed. We analyzed 159 samples, each split into 16 aliquots, of which one-half (8) were processed promptly after collection. The remaining half (8) were processed the following day to assess impact of holding/shipping time. A total of 2544 samples were analyzed including replicates. After accounting for inherent measurement error, we found that the effect of holding time on observed Legionella counts was small and should have no practical impact on interpretation of results. Holding samples increased the root mean squared error by only about 3-8%. Notably, for only one of 159 samples, did the average of the 8 replicate counts change by 1 log. Thus, our findings do not support the hypothesis of frequent, significant (≥= 1 log10 unit) Legionella colony count changes due to holding. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Contributions for the application of a phoswich detector on the analysis of environmental samples

    International Nuclear Information System (INIS)

    Dalaqua Junior, L.

    1989-01-01

    The characteristics of a phoswich detector and the parameters of the pulse shape descrimination system are evaluated aiming the application on environmental analysis by direct low level gamma ray spectrometry. The calibration curves and adjustments for the pulse discrimination, detector resolution and homogeneity measurements are presented. Background reduction and the 210 Pb detection eficiency on evaporated sources are evaluated. The results obtained demonstrates the application potentiality on the analysis of environmental samples due to a high detection eficiency and good geometry conditions to the measurements. (author) [pt

  13. Amoco-US Environmental Protection Agency, pollution prevention project, Yorktown, Virginia: Surface water data

    International Nuclear Information System (INIS)

    Baloo, S.

    1991-08-01

    The report summarizes the surface water sampling program at the Amoco Refinery at Yorktown, Virginia. This was undertaken as a part of the joint project between Amoco Corporation and the United States Environmental Protection Agency to review pollution prevention alternatives at a petroleum refinery. The surface water data provides a snapshot of surface water pollutant generation and discharge from the refinery. Different process units contribute to the total wastewater flow of 460 GPM in the refinery. Water in the ditch system, which is non-process water, is free of organic contamination. Oil and grease, phenols, ammonia and sulfides are the significant components measured in the process wastewater. The concentrations of organics in most water streams leaving the individual process units are relatively low, in the 1-5 parts per million (ppm) range. A few individual streams such as the crude desalter brine and tank water draws have high pollutant loadings. Concentrations of metals in the refinery wastewater are very low. The wastewater treatment plant is very effective in reducing the pollutant loading in the water with overall removal efficiencies greater than 99% for most organics and inorganics

  14. Radionuclides concentration in marine environmental samples along the coast of Vietnam

    International Nuclear Information System (INIS)

    Nguyen Trong Ngo; Nguyen Thanh Binh; Nguyen Van Phuc; Le Nhu Sieu; Truong Y; Mai Thi Huong; Nguyen Thi Linh; Nguyen Mong Sinh; Phan Son Hai; Le Ngoc Chung; Dang Duc Nhan; Nguyen Quang Long; Nguyen Hao Quang; Tran Tuyet Mai

    2009-01-01

    Studies on radioactivity inventories in environmental samples are necessary as they will serve as baseline data for assessing any environmental impact usage of nuclear-based activities. Approximately 700 data on 238 U, 232 Th, 226 Ra, 90 Sr, 137 Cs, 239,240 Pu activity concentrations in 150 samples i.e. sea water, sediment, fish, mollusc, crustaceans, oyster and weeds samples collected from 7 various locations in Vietnam (Hai Phong, Nghe An, Khanh Hoa, Ninh Thuan, Binh Thuan, Vung Tau, Tien Giang) throughout 1999-2008 are summarised and presented in this paper. Generally, the levels of artificial radionuclides in the studied marine environmental samples are lower as compared to other Asia-Pacific countries while naturally occurred radionuclides activity concentrations obtained were found to be in accordance with respective data from other studies within Pacific region. The radionuclides bioaccumulation factors studied in Red laver and oyster were mostly found to be high; therefore, further reinvestigation should be done for these biota that will be used as bio-fingerprint indicators in monitoring the marine environment from nuclear-based pollutions. The data set obtained from this study is available to the Asia-Pacific Marine Radioactivity Database. (author)

  15. A DOE manual: DOE Methods for Evaluating Environmental and Waste Management Samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Riley, R.G.

    1994-01-01

    Waste Management inherently requires knowledge of the waste's chemical composition. The waste can often be analyzed by established methods; however, if the samples are radioactive, or are plagued by other complications, established methods may not be feasible. The US Department of Energy (DOE) has been faced with managing some waste types that are not amenable to standard or available methods, so new or modified sampling and analysis methods are required. These methods are incorporated into DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), which is a guidance/methods document for sampling and analysis activities in support of DOE sites. It is a document generated by consensus of the DOE laboratory staff and is intended to fill the gap within existing guidance documents (e. g., the Environmental Protection Agency's (EPA's) Test Methods for Evaluating Solid Waste, SW-846), which apply to low-level or non-radioactive samples. DOE Methods fills the gap by including methods that take into account the complexities of DOE site matrices. The most recent update, distributed in October 1993, contained quality assurance (QA), quality control (QC), safety, sampling, organic analysis, inorganic analysis, and radioanalytical guidance as well as 29 methods. The next update, which will be distributed in April 1994, will contain 40 methods and will therefore have greater applicability. All new methods are either peer reviewed or labeled ''draft'' methods. Draft methods were added to speed the release of methods to field personnel

  16. Fluorimetric determination of uranium in certain refractory minerals, environmental samples and industrial waste materials

    International Nuclear Information System (INIS)

    Premadas, A.; Saravanakumar, G.

    2005-01-01

    A simple sample decomposition and laser fluorimetric determination of uranium at trace level is reported in certain refractory minerals, like ilmenite, rutile, zircon and monazite; environmental samples viz. soil and sediments; industrial waste materials, such as, coal fly ash and red mud. Ilmenite sample is decomposed by heating with ammonium fluoride. Rutile, zircon and monazite minerals are decomposed by fusion using a mixture of potassium bifluoride and sodium fluoride. Environmental and industrial waste materials are brought into solution by treating with a mixture of hydrofluoric and nitric acids. The laser induced fluorimetric determination of uranium is carried out directly in rutile, zircon and in monazite minerals and after separation in other samples. The determination limit was 1 μg x g -1 for ilmenite, soil, sediment, coal fly ash and red mud samples, and it is 5 μg x g -1 for rutile, zircon and monazite. The method is also developed for the optical fluorimetric determination of uranium (determination limit 10 μg x g -1 ) in ilmenite, rutile, zircon and monazite minerals. The methods are simple, accurate, and precise and they require small quantity of sample and can be applied for the routine analysis. (author)

  17. Magnetic hydroxyapatite nanoparticles: an efficient adsorbent for the separation and removal of nitrate and nitrite ions from environmental samples.

    Science.gov (United States)

    Ghasemi, Ensieh; Sillanpää, Mika

    2015-01-01

    A novel type of magnetic nanosorbent, hydroxyapatite-coated Fe2O3 nanoparticles was synthesized and used for the adsorption and removal of nitrite and nitrate ions from environmental samples. The properties of synthesized magnetic nanoparticles were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and X-ray powder diffraction. After the adsorption process, the separation of γ-Fe2O3@hydroxyapatite nanoparticles from the aqueous solution was simply achieved by applying an external magnetic field. The effects of different variables on the adsorption efficiency were studied simultaneously using an experimental design. The variables of interest were amount of magnetic hydroxyapatite nanoparticles, sample volume, pH, stirring rate, adsorption time, and temperature. The experimental parameters were optimized using a Box-Behnken design and response surface methodology after a Plackett-Burman screening design. Under the optimum conditions, the adsorption efficiencies of magnetic hydroxyapatite nanoparticles adsorbents toward NO3(-) and NO2(-) ions (100 mg/L) were in the range of 93-101%. The results revealed that the magnetic hydroxyapatite nanoparticles adsorbent could be used as a simple, efficient, and cost-effective material for the removal of nitrate and nitrite ions from environmental water and soil samples. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Ultrasensitive determination of formaldehyde in environmental waters and food samples after derivatization and using silver nanoparticle assisted SERS

    International Nuclear Information System (INIS)

    Ma, Pinyi; Wang, Di; Yang, Qingqing; Song, Daqian; Wang, Xinghua; Liang, Fanghui; Ding, Yaying; Yu, Yong; Gao, Dejiang

    2015-01-01

    A selective and ultrasensitive surface-enhanced Raman spectroscopy (SERS) method was developed for the determination of formaldehyde (HCHO) in environmental waters and food samples. It is based on derivatization of HCHO with 4-amino-5-hydrazino-3-mercapto-1,2,4-triazole (AHMT) with HCHO. One of the products of the derivative reaction, 6-mercapto-5-triazolo[4,3-b]-s-tetrazine (MTT), can be quantified by SERS at 832 cm −1 using silver nanoparticles (AgNPs) as substrates. The incubation time for derivatization, the volume of reagents and the mixing times were optimized. The peak areas of the SERS are linearly related to the concentration of HCHO in the 1 − 1,000 μg L −1 range, the limit of detection is 0.15 μg L −1 , and the limit of quantification is 0.45 μg L −1 . Recoveries obtained by analyzing two spiked samples of environmental water and two spiked food samples were in the range between 91.0 and 108.7 %. There is no significant difference between the results obtained by the present method and the liquid chromatographic method (Chinese industrial standard method, SN/T 1547-2011). (author)

  19. Differential efficiencies of dip-net sampling versus sampling surface-floating pupal exuviae in a biodiversity survey of Chironomidae

    Directory of Open Access Journals (Sweden)

    Leonard Charles Ferrington Jr

    2014-12-01

    Full Text Available Relative efficiencies of standard dip-net sampling (SDN versus collections of surface-floating pupal exuviae (SFPE were determined for detecting Chironomidae at catchment and site scales and at subfamily/tribe-, genus- and species-levels based on simultaneous, equal-effort sampling on a monthly basis for one year during a biodiversity assessment of Bear Run Nature Reserve. Results showed SFPE was more efficient than SDN at catchment scales for detecting both genera and species. At site scales, SDN sampling was more efficient for assessment of a first-order site. No consistent pattern, except for better efficiency of SFPE to detect Orthocladiinae genera, was observed at genus-level for two second-order sites. However, SFPE was consistently more efficient at detecting species of Orthocladiinae, Chironomini and Tanytarsini at the second order sites. SFPE was more efficient at detecting both genera and species at two third-order sites. The differential efficiencies of the two methods are concluded to be related to stream order and size, substrate size, flow and water velocity, depth and habitat heterogeneity, and differential ability to discriminate species among pupal exuviae specimens versus larval specimens. Although both approaches are considered necessary for comprehensive biodiversity assessments of Chironomidae, our results suggest that there is an optimal, but different, allocation of sampling effort for detecting Chironomidae across stream orders and at differing spatial and taxonomic scales.Article submitted 13. August 2014, accepted 31. October 2014, published 22. December 2014.

  20. Cracks and nanodroplets produced on tungsten surface samples by dense plasma jets

    Science.gov (United States)

    Ticoş, C. M.; Galaţanu, M.; Galaţanu, A.; Luculescu, C.; Scurtu, A.; Udrea, N.; Ticoş, D.; Dumitru, M.

    2018-03-01

    Small samples of 12.5 mm in diameter made from pure tungsten were exposed to a dense plasma jet produced by a coaxial plasma gun operated at 2 kJ. The surface of the samples was analyzed using a scanning electron microscope (SEM) before and after applying consecutive plasma shots. Cracks and craters were produced in the surface due to surface tensions during plasma heating. Nanodroplets and micron size droplets could be observed on the samples surface. An energy-dispersive spectroscopy (EDS) analysis revealed that the composition of these droplets coincided with that of the gun electrode material. Four types of samples were prepared by spark plasma sintering from powders with the average particle size ranging from 70 nanometers up to 80 μm. The plasma power load to the sample surface was estimated to be ≈4.7 MJ m-2 s-1/2 per shot. The electron temperature and density in the plasma jet had peak values 17 eV and 1.6 × 1022 m-3, respectively.

  1. Improved explosive collection and detection with rationally assembled surface sampling materials

    Energy Technology Data Exchange (ETDEWEB)

    Chouyyok, Wilaiwan; Bays, J. Timothy; Gerasimenko, Aleksandr A.; Cinson, Anthony D.; Ewing, Robert G.; Atkinson, David A.; Addleman, R. Shane

    2016-01-01

    Sampling and detection of trace explosives is a key analytical process in modern transportation safety. In this work we have explored some of the fundamental analytical processes for collection and detection of trace level explosive on surfaces with the most widely utilized system, thermal desorption IMS. The performance of the standard muslin swipe material was compared with chemically modified fiberglass cloth. The fiberglass surface was modified to include phenyl functional groups. When compared to standard muslin, the phenyl functionalized fiberglass sampling material showed better analyte release from the sampling material as well as improved response and repeatability from multiple uses of the same swipe. The improved sample release of the functionalized fiberglass swipes resulted in a significant increase in sensitivity. Various physical and chemical properties were systematically explored to determine optimal performance. The results herein have relevance to improving the detection of other explosive compounds and potentially to a wide range of other chemical sampling and field detection challenges.

  2. May 2012 Groundwater and Surface Water Sampling at the Rio Blanco, Colorado, Site (Data Validation Package)

    International Nuclear Information System (INIS)

    2012-01-01

    Annual sampling was conducted at the Rio Blanco, Colorado, site for the Long-Term Hydrologic Monitoring Program May 9-10, 2012, to monitor groundwater and surface water for potential radionuclide contamination. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for the U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). A duplicate sample was collected from location Johnson Artesian WL. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry and for tritium using the conventional and enrichment methods. Results of this monitoring at the Rio Blanco site demonstrate that groundwater and surface water outside the site boundaries have not been affected by project-related contaminants.

  3. Environmental DNA method for estimating salamander distribution in headwater streams, and a comparison of water sampling methods.

    Science.gov (United States)

    Katano, Izumi; Harada, Ken; Doi, Hideyuki; Souma, Rio; Minamoto, Toshifumi

    2017-01-01

    Environmental DNA (eDNA) has recently been used for detecting the distribution of macroorganisms in various aquatic habitats. In this study, we applied an eDNA method to estimate the distribution of the Japanese clawed salamander, Onychodactylus japonicus, in headwater streams. Additionally, we compared the detection of eDNA and hand-capturing methods used for determining the distribution of O. japonicus. For eDNA detection, we designed a qPCR primer/probe set for O. japonicus using the 12S rRNA region. We detected the eDNA of O. japonicus at all sites (with the exception of one), where we also observed them by hand-capturing. Additionally, we detected eDNA at two sites where we were unable to observe individuals using the hand-capturing method. Moreover, we found that eDNA concentrations and detection rates of the two water sampling areas (stream surface and under stones) were not significantly different, although the eDNA concentration in the water under stones was more varied than that on the surface. We, therefore, conclude that eDNA methods could be used to determine the distribution of macroorganisms inhabiting headwater systems by using samples collected from the surface of the water.

  4. An integrated high temperature environmental cell for atom probe tomography studies of gas-surface reactions: Instrumentation and results

    International Nuclear Information System (INIS)

    Dumpala, S.; Broderick, S.R.; Bagot, P.A.J.; Rajan, K.

    2014-01-01

    An integrated environmental cell has been designed and developed for the latest generation of Atom Probe Tomography LEAP™ instruments, allowing controlled exposure of samples to gases at high temperatures. Following treatment, samples can be transferred through the LEAP vacuum system for subsequent APT analysis, which provides detailed information on changes to chemical microstructures following the reactions with near-atomic resolution. A full description of the cell is presented, along with some sample results on the oxidation of aluminum and two platinum-group alloys, demonstrating the capability of combining exposure/characterization functionality in a single instrument. - Highlights: • Designed and built atom probe environmental cell for in situ reactions. • Investigated Al oxidation, and demonstrated improvement with new cell. • in situ APT analysis of Pt-alloys showed surface segregation of Rh and Ir

  5. Environmental impact of by pass channel of surface waters

    International Nuclear Information System (INIS)

    Vismara, R.; Renoldi, M.; Torretta, V.

    1996-01-01

    In this paper are analyzed the impacts generated by surface waters drawing on river course. This impacts are generated also by reduction of water flow. This effect is most important for the presence of biological community: algae, fiches, micro invertebrates. Are also reported regional laws, water master plan of Lombardia region

  6. Dynamic Flow-through Methods for Metal Fractionation in Environmental Solid Samples

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald; Petersen, Roongrat

    occurring processes always take place under dynamic conditions, recent trends have been focused on the development of alternative flow-through dynamic methods aimed at mimicking environmental events more correctly than their classical extraction counterparts. In this lecture particular emphasis is paid......Accummulation of metal ions in different compartments of the biosphere and their possible mobilization under changing environmental conditions induce a pertubation of the ecosystem and may cause adverse health effects. Nowadays, it is widely recognized that the information on total content...... the ecotoxicological significance of metal ions in solid environmental samples. The background of end-over-end fractionation for releasing metal species bound to particular soil phases is initially discussed, its relevant features and limitations being thoroughly described. However, taking into account that naturally...

  7. Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

    Energy Technology Data Exchange (ETDEWEB)

    Addleman, Raymond S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Naes, Benjamin E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McNamara, Bruce K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Olsen, Khris B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chouyyok, Wilaiwan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Willingham, David G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Spigner, Angel C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-30

    The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmental sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for

  8. Veterinary antibiotic resistance, residues, and ecological risks in environmental samples obtained from poultry farms, Egypt.

    Science.gov (United States)

    Dahshan, Hesham; Abd-Elall, Amr Mohamed Mohamed; Megahed, Ayman Mohamed; Abd-El-Kader, Mahdy A; Nabawy, Ehab Elsayed

    2015-02-01

    In Egypt, poultry production constitutes one of the main sources of pollution with veterinary antibiotics (VAs) into the environment. About 80 % of meat production in Egypt is of poultry origin, and the potential environmental risks associated with the use of VAs in these farms have not yet been properly evaluated. Thus, the main purpose of this research was to evaluate the prevalence of antibiotic-resistant enteric key bacteria and the incidence of residual antibiotics in poultry farm environmental samples and to determine whether fertilizing soils with poultry litter from farms potentially brings ecological risks. From December 2011 to September 2012, a total of 225 litter, bird dropping, and water samples were collected from 75 randomly selected boiler poultry farms. A high prevalence of Escherichia coli (n = 179; 79.5 %) in contrast to the low prevalence of Salmonella spp. (n = 7; 3.1 %) was detected. Amongst E. coli isolates, serotypes O142:K86, O125:K70, O91:K, and O119:K69 were the most common. Meanwhile, Salmonella enterica serotypes emek and enteritidis were recovered. The antibiograms using the disc diffusion method revealed significantly more common resistant and multi-resistant isolates in broiler poultry farms. Residues of tetracycline and ciprofloxacin were detected at 2.125 and 1.401 mg kg(-1) mean levels, respectively, in environmental samples contaminated with E. coli-resistant strains by HPLC. The risk evaluations highlighted that tetracycline residues in poultry litter significantly display environmental risks with a hazard quotient value above 1 (1.64). Our study implies that ineffective implementation of veterinary laws which guide and guard against incorrect VA usage may potentially bring health and environmental risks.

  9. Specific calibration problems for gammaspectrometric measurements of low-level radioactivity in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, D [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Wershofen, H [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)

    1997-03-01

    Gammaspectrometric measurements of low-level radioactivity in environmental samples are always done in a close source detector geometry. This geometry causes coincidence-summing effects for measurements of multi-photon emitting nuclides. The measurements of radioactivity in environmental samples are also influenced by the absorption of photons in the materials which have to be analysed. Both effects must be taken into account by correction factors with respect to an energy-specific calibration of the detector system for a given geometry and a given composition of the calibration source. The importance of these corrections is emphasized. It is the aim of the present paper to compare different experimental and theoretical methods for the determination of these correction factors published by various authors and to report about efforts to refine them. (orig.)

  10. Determination of uranium isotopes in environmental samples by anion exchange in sulfuric and hydrochloric acid media

    International Nuclear Information System (INIS)

    Popov, L.

    2016-01-01

    Method for determination of uranium isotopes in various environmental samples is presented. The major advantages of the method are the low cost of the analysis, high radiochemical yields and good decontamination factors from the matrix elements, natural and man-made radionuclides. The separation and purification of uranium is attained by adsorption with strong base anion exchange resin in sulfuric and hydrochloric acid media. Uranium is electrodeposited on a stainless steel disk and measured by alpha spectrometry. The analytical method has been applied for the determination of concentrations of uranium isotopes in mineral, spring and tap waters from Bulgaria. The analytical quality was checked by analyzing reference materials. - Highlights: • The method allows cost-effective determination of U isotopes. • High amounts of environmental samples can be analyzed. • High chemical yields, energy resolution and decontamination factors were achieved. • Uranium isotope concentrations in mineral waters from Bulgaria are presented.

  11. Determination and interpretation of environmental water samples contaminated by uranium mining activities

    International Nuclear Information System (INIS)

    Meinrath, G.; Volke, P.; Helling, C.; Merkel, B.J.; Dudel, E.G.

    1999-01-01

    Interpretation of environmental behavior of uranium is based on several steps of data analysis and statistical inference. First step is sampling and analyzing of uranium in field samples by routine laboratory methods. Such methods have to fulfill multiple requirements like robustness, efficiency, low detection limit and precision. A comparison of different approaches in assigning uncertainty to experimentally obtained analytical data shows that classical error estimation is not significantly inferior to more sophisticated modern techniques like inverse regression or orthogonal regression. A second step is the correlation of analytical data with current state of insight into environmental behavior of uranium. Such a correlation furthers the choice of adequate geochemical models and quality of geochemical data base for subsequent detailed analysis, e.g. by geochemical modeling. An appraisal of the individual steps in this complex analysis is given on the basis of statistical procedures for calibration and an E H -pH diagram of uranium for atmospheric conditions. (orig.)

  12. Validated methodology for quantifying infestation levels of dreissenid mussels in environmental DNA (eDNA) samples.

    Science.gov (United States)

    Peñarrubia, Luis; Alcaraz, Carles; Vaate, Abraham Bij de; Sanz, Nuria; Pla, Carles; Vidal, Oriol; Viñas, Jordi

    2016-12-14

    The zebra mussel (Dreissena polymorpha Pallas, 1771) and the quagga mussel (D. rostriformis Deshayes, 1838) are successful invasive bivalves with substantial ecological and economic impacts in freshwater systems once they become established. Since their eradication is extremely difficult, their detection at an early stage is crucial to prevent spread. In this study, we optimized and validated a qPCR detection method based on the histone H2B gene to quantify combined infestation levels of zebra and quagga mussels in environmental DNA samples. Our results show specific dreissenid DNA present in filtered water samples for which microscopic diagnostic identification for larvae failed. Monitoring a large number of locations for invasive dreissenid species based on a highly specific environmental DNA qPCR assay may prove to be an essential tool for management and control plans focused on prevention of establishment of dreissenid mussels in new locations.

  13. Prevalence of L. monocytogenes in environmental samples collected in dairy plants of Sassari Province, Italy

    Directory of Open Access Journals (Sweden)

    Giovanni Terrosu

    2015-09-01

    Full Text Available Listeria (L. monocytogenes is frequently isolated from food production environment and often persists in dairy plants despite vigorous sanitation regimes. In recent years several alert notifications were sent to Rapid Alert System for Food Products system as a consequence of Listeria monocytogenes contamination of ricotta cheese. After the alert of 2012, competent authority (Local Health Unit of Sassari Province organised an environmental monitoring plan with the partnership of the Institute for Experimental Veterinary Medicine of Sardinia to verify analysis of dairy plants own-check according to Regulation (EC N° 2073/05 and further modifications. In 2014 n. 665 processing areas samples of n. 50 dairy plants of Sassari Province were examined. UNI EN ISO 11290-1:2005 for detection of L. monocytogenes was used. Non-compliance in n. 5 diary plants are observed (n. 8 positive samples. Post-non-compliance environmental sanitisation was efficient and own-check plans included appropriate corrective actions.

  14. Revisiting the environmental Kuznets curve and pollution haven hypotheses: MIKTA sample.

    Science.gov (United States)

    Bakirtas, Ibrahim; Cetin, Mumin Atalay

    2017-08-01

    This study aims to examine the validity of the environmental Kuznets curve (EKC) and pollution haven hypotheses in Mexico, Indonesia, South Korea, Turkey, and Australia (MIKTA) countries from 1982 to 2011 by using a panel vector auto regressive (PVAR) model. Empirical findings imply that the EKC hypothesis is rejected by the MIKTA sample. However, PVAR estimations reveal Granger causality from income level, foreign direct investment (FDI) inward, and energy consumption to CO 2 emissions. Orthogonalized impulse-response functions are derived from PVAR estimations. According to the analysis results, the response of CO 2 emissions to a shock on FDI is positive. These results assert that FDI has a detrimental effect on environmental quality in MIKTA countries which means the pollution haven hypothesis is confirmed by the MIKTA sample. Therefore, MIKTA countries should revise their current economic growth plans to provide sustainable development and also re-organize their legal infrastructure to induce usage of renewable energy sources.

  15. Optical molecular fluorescence determination of ultra-trace beryllium in occupational and environmental samples using highly alkaline conditions.

    Science.gov (United States)

    Adams, Lori; Agrawal, Anoop; Cronin, John P; Ashley, Kevin

    2017-01-01

    Exposures to beryllium (Be), even at extremely low levels, can cause severe health effects in a percentage of those exposed; consequently, occupational exposure limits (OELs) promulgated for this element are the lowest established for any element. This work describes the advantages of using highly alkaline dye solutions for determination of Be in occupational hygiene and environmental samples by means of an optical molecular fluorescence technique after sample extraction in 1-3% (w˖w -1 ) aqueous ammonium bifluoride (NH 4 HF 2 ). Improved attributes include the ability to further enhance the detection limits of Be in extraction solutions of high acidity with minimal dilution, which is particularly beneficial when NH 4 HF 2 solutions of higher concentration are used for extraction of Be from soil samples. Significant improvements in Be method detection limits (MDLs) are obtained at levels many-fold below those reported previously for this methodology. Notably, MDLs for Be of health organizations and regulatory agencies in the USA and internationally. Applications of enhanced Be measurements to air filter samples, surface wipe samples, soils and newly-designed occupational air sampler inserts are illustrated.

  16. Measurements of 222Rn and 226Ra Levels in environmental samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Moustafa, A.S.

    2004-01-01

    The advantageous of liquid scintillation counting technique for 6 Ra determination compared with other methods are the high counting efficiency and the easier sample preparation, with no need for sample pre-concentration. In this work, liquid scintillation counting system was used to measure 222 Rn and 226 Ra levels in environmental samples. The liquid scintillation cocktail was prepared in the laboratory and was found efficient for measuring 222 Rn. Soil, sediment and TENORM samples were dried, grind, sieved and added to hydrochloric acid, in a standard scintillation vial, preloaded with the liquid scintillation cocktail. By measuring 222 Rn levels in the prepared vials, at different intervals of time after preparation, 222 Rn and 226 Ra levels were determined

  17. Evaluating the suitability of different environmental samples for tracing atmospheric pollution in industrial areas.

    Science.gov (United States)

    Francová, Anna; Chrastný, Vladislav; Šillerová, Hana; Vítková, Martina; Kocourková, Jana; Komárek, Michael

    2017-01-01

    Samples of lichens, snow and particulate matter (PM 10 , 24 h) are used for the source identification of air pollution in the heavily industrialized region of Ostrava, Upper Silesia, Czech Republic. An integrated approach that uses different environmental samples for metal concentration and Pb isotope analyses was applied. The broad range of isotope ratios in the samples indicates a combination of different pollution sources, the strongest among them being the metallurgical industry, bituminous coal combustion and traffic. Snow samples are proven as the most relevant indicator for tracing metal(loid)s and recent local contamination in the atmosphere. Lichens can be successfully used as tracers of the long-term activity of local and remote sources of contamination. The combination of PM 10 with snow can provide very useful information for evaluation of current pollution sources. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Determination of 90Sr in environmental samples with resonance ionization spectroscopy in collinear geometry

    International Nuclear Information System (INIS)

    Zimmer, K.; Stenner, J.; Kluge, H.J.; Lantzsch, J.; Monz, L.; Otten, E.W.; Passler, G.; Schwalbach, R.; Schwarz, M.; Stevens, H.; Wendt, K.; Herrmann, G.; Niess, S.; Trautmann, N.; Walter, K.; Bushaw, B.A.

    1994-01-01

    A new, fast technique for trace analysis of the radioactive isotopes 89 Sr and 90 Sr in environmental samples has been developed. Conventional mass separation is combined with resonance ionization spectroscopy in collinear geometry, which provides high selectivity and sensitivity. In addition, a chemical separation procedure for sample preparation has been developed. The described technique was used to determine the 90 Sr content in ∼ 870 m 3 air samples collected near Munich during and shortly after the Chernobyl reactor accident in April 1986. The content of 90 Sr was measured to be 1.4 mBq per m 3 , corresponding to 1.6 x 10 9 atoms of 90 Sr per sample. This value is in good agreement with the results of radiochemical measurements. (orig.)

  19. Determination of [sup 90]Sr in environmental samples with resonance ionization spectroscopy in collinear geometry

    Energy Technology Data Exchange (ETDEWEB)

    Zimmer, K. (Inst. fuer Physik, Univ. Mainz (Germany)); Stenner, J. (Inst. fuer Physik, Univ. Mainz (Germany)); Kluge, H.J. (Inst. fuer Physik, Univ. Mainz (Germany)); Lantzsch, J. (Inst. fuer Physik, Univ. Mainz (Germany)); Monz, L. (Inst. fuer Physik, Univ. Mainz (Germany)); Otten, E.W. (Inst. fuer Physik, Univ. Mainz (Germany)); Passler, G. (Inst. fuer Physik, Univ. Mainz (Germany)); Schwalbach, R. (Inst. fuer Physik, Univ. Mainz (Germany)); Schwarz, M. (Inst. fuer Physik, Univ. Mainz (Germany)); Stevens, H. (Inst. fuer Physik, Univ. Mainz (Germany)); Wendt, K. (Inst. fuer Physik, Univ. Mainz (Germany)); Herrmann, G. (Inst. fuer Kernchemie, Univ. Mainz (Germany)); Niess, S. (Inst. fuer Kernchemie, Univ. Mainz (Germany)); Trautmann, N. (Inst. fuer Kernchemie, Univ. Mainz (Germany)); Walter, K. (Inst. fuer Kernchemie, Univ. Mainz (Germany)); Bushaw, B.A. (Pacific Northwest Lab., Richland, WA (United States))

    1994-08-01

    A new, fast technique for trace analysis of the radioactive isotopes [sup 89]Sr and [sup 90]Sr in environmental samples has been developed. Conventional mass separation is combined with resonance ionization spectroscopy in collinear geometry, which provides high selectivity and sensitivity. In addition, a chemical separation procedure for sample preparation has been developed. The described technique was used to determine the [sup 90]Sr content in [approx] 870 m[sup 3] air samples collected near Munich during and shortly after the Chernobyl reactor accident in April 1986. The content of [sup 90]Sr was measured to be 1.4 mBq per m[sup 3], corresponding to 1.6 x 10[sup 9] atoms of [sup 90]Sr per sample. This value is in good agreement with the results of radiochemical measurements. (orig.)

  20. Modern Trends in Neutron Activation Analysis. Applications to some African Environmental Samples

    International Nuclear Information System (INIS)

    Hassan, A.M.

    2009-01-01

    This review covers the results of several published articles which deal with the modern trends in neutron activation analysis techniques using some of African research reactors for some environmental samples. The samples used have been collected from different areas in Egypt, South Africa, Ghana, Morocco, Nigeria, and Algeria. The neutron irradiation facilities and the advanced detection systems in each country are outlined. The prompt and delayed gamma-rays emitted due to neutron capture have been applied for investigation of the elemental constituents of such samples. Covered applications include exploration, mining, industrial environment, pollution of air, foodstuffs, soils and irrigation water samples. Some of the developed software programmes as well as the modern methods of data analysis are presented. The thermal and epithermal neutron activation analysis techniques have been applied for estimation of major, minor and trace elements in each material. Some of these data are presented with several comments.

  1. Improvements to sample processing and measurement to enable more widespread environmental application of tritium.

    Science.gov (United States)

    Moran, James; Alexander, Thomas; Aalseth, Craig; Back, Henning; Mace, Emily; Overman, Cory; Seifert, Allen; Freeburg, Wilcox

    2017-08-01

    Previous measurements have demonstrated the wealth of information that tritium (T) can provide on environmentally relevant processes. We present modifications to sample preparation approaches that enable T measurement by proportional counting on small sample sizes equivalent to 120mg of water and demonstrate the accuracy of these methods on a suite of standardized water samples. We identify a current quantification limit of 92.2 TU which, combined with our small sample sizes, correlates to as little as 0.00133Bq of total T activity. This enhanced method should provide the analytical flexibility needed to address persistent knowledge gaps in our understanding of both natural and artificial T behavior in the environment. Copyright © 2017. Published by Elsevier Ltd.

  2. Basic distribution free identification tests for small size samples of environmental data

    International Nuclear Information System (INIS)

    Federico, A.G.; Musmeci, F.

    1998-01-01

    Testing two or more data sets for the hypothesis that they are sampled form the same population is often required in environmental data analysis. Typically the available samples have a small number of data and often then assumption of normal distributions is not realistic. On the other hand the diffusion of the days powerful Personal Computers opens new possible opportunities based on a massive use of the CPU resources. The paper reviews the problem introducing the feasibility of two non parametric approaches based on intrinsic equi probability properties of the data samples. The first one is based on a full re sampling while the second is based on a bootstrap approach. A easy to use program is presented. A case study is given based on the Chernobyl children contamination data [it

  3. A solid phase extraction-ion chromatography with conductivity detection procedure for determining cationic surfactants in surface water samples.

    Science.gov (United States)

    Olkowska, Ewa; Polkowska, Żaneta; Namieśnik, Jacek

    2013-11-15

    A new analytical procedure for the simultaneous determination of individual cationic surfactants (alkyl benzyl dimethyl ammonium chlorides) in surface water samples has been developed. We describe this methodology for the first time: it involves the application of solid phase extraction (SPE-for sample preparation) coupled with ion chromatography-conductivity detection (IC-CD-for the final determination). Mean recoveries of analytes between 79% and 93%, and overall method quantification limits in the range from 0.0018 to 0.038 μg/mL for surface water and CRM samples were achieved. The methodology was applied to the determination of individual alkyl benzyl quaternary ammonium compounds in environmental samples (reservoir water) and enables their presence in such types of waters to be confirmed. In addition, it is a simpler, less time-consuming, labour-intensive, avoiding use of toxic chloroform and significantly less expensive methodology than previously described approaches (liquid-liquid extraction coupled with liquid chromatography-mass spectrometry). Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Simultaneous analysis of arsenic, antimony, selenium and tellurium in environmental samples using hydride generation ICPMS

    International Nuclear Information System (INIS)

    Jankowski, L.M.; Breidenbach, R.; Bakker, I.J.I.; Epema, O.J.

    2009-01-01

    Full text: A quantitative method for simultaneous analysis of arsenic, antimony, selenium and tellurium in environmental samples is being developed using hydride generation ICPMS. These elements must be first transformed into hydride-forming oxidation states. This is particularly challenging for selenium and antimony because selenium is susceptible to reduction to the non-hydride-forming elemental state and antimony requires strong reducing conditions. The effectiveness of three reducing agents (KI, thiourea, cysteine) is studied. A comparison is made between addition of reducing agent to the sample and addition of KI to the NaBH 4 solution. Best results were obtained with the latter approach. (author)

  5. Application of semiempirical expressions to the alpha and beta radiometry of environmental depositions samples

    International Nuclear Information System (INIS)

    Perez Tamayo, L.

    1996-01-01

    Were applied two semiempirical equations exponential beta absorption and Bragg-Kleeman approximation complementary to experimental corrections for beta backscattering and auto absorption of beta and alpha radiations in measurements of environmental depositions samples In the first case was verified the validity of mentioned corrections with an application boundary to mass greater than 300 Pb-210 (0.015 mg/cm 2 ) In the second case, the Bragg-Kleeman approximation combined with the experimental beta corrections, bring a judgment to determine the fundamental alpha and beta emisors samples which results the Pb-210 group

  6. Solid-phase extraction and determination of trace elements in environmental samples using naphthalene adsorbent

    International Nuclear Information System (INIS)

    Pourreza, N.

    2004-01-01

    Naphthalene co-precipitated with quaternary ammonium salt such as tetraoctyl ammonium bromide and methyltrioctyl ammonium chloride have been used as adsorbent for solid phase extraction of metal ions such as Hg, Cd and Fe. The metal ions are retained on the adsorbent in a column as their complexes with suitable ligands and eluted by an eluent before instrumental measurements. The optimization of the procedures for solid phase extraction and consequent determination of trace elements and application to environmental samples especially water samples will be discussed. (author)

  7. Trace element analysis of environmental samples by multiple prompt gamma-ray analysis method

    International Nuclear Information System (INIS)

    Oshima, Masumi; Matsuo, Motoyuki; Shozugawa, Katsumi

    2011-01-01

    The multiple γ-ray detection method has been proved to be a high-resolution and high-sensitivity method in application to nuclide quantification. The neutron prompt γ-ray analysis method is successfully extended by combining it with the γ-ray detection method, which is called Multiple prompt γ-ray analysis, MPGA. In this review we show the principle of this method and its characteristics. Several examples of its application to environmental samples, especially river sediments in the urban area and sea sediment samples are also described. (author)

  8. Evaluation of the readsorption of plutonium and americium in dynamic fractionations of environmental solid samples

    DEFF Research Database (Denmark)

    Petersen, Roongrat; Hou, Xiaolin; Hansen, Elo Harald

    2008-01-01

    A dynamic extraction system exploiting sequential injection (SI) for sequential extractions incorporating a specially designed extraction column is developed to fractionate radionuclides in environmental solid samples such as soils and sediments. The extraction column can contain a large amount...... of soil sample (up to 5 g), and under optimal operational conditions it does not give rise to creation of back pressure. Attention has been placed on studies of the readsorption problems during sequential extraction using a modified Standards, Measurements and Testing (SM&T) scheme with 4-step sequential...

  9. Practice and experience in traceability of radioactivity measurements of environmental samples

    International Nuclear Information System (INIS)

    Huang Zhijian

    1990-01-01

    This paper discusses some aspects on radioactivity measurement traceability and summarizes the work on quality assurance of radioactivity measurements of environmental samples in the laboratory, including transfer of standards, preparation of reference materials, and calibration of efficiency for volumse surces with Ge(Li) spectrometer. Some practical activitis regarding intercomparison of radioactivity measurements and other traceabillity-related activities are also described. Some sugestions relating to performing quality assurance are made

  10. High efficiency environmental sampling with UV-cured peelable coatings (aka NuGoo project)

    Energy Technology Data Exchange (ETDEWEB)

    Henzl, Vladimir [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Junghans, Sylvia Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lakis, Rollin Evan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-21

    This report presents slides on CA Related Project (FY13-17); Environmental sampling by IAEA (not only) during CA; Decontamination gels; Cotton swipes vs. decon gel (FY15); Contamination removal study; The origins of the NuGoo; NuGoo – proof of concept; NuGoo – FY17 project ($250K); LED lamp – which one works and why; Selecting photoinitiator; Monomers and oligomers; Results.

  11. Preparation of Magnetic Sorbent with Surface Modified by C18for Removal of Selected Organic Pollutants from Aqueous Samples

    Science.gov (United States)

    Kuráň, Pavel; Pilnaj, Dominik; Ciencialová, Lucie; Pšenička, Martin

    2017-12-01

    Magnetic sorbents have great potential in environmental applications due to their simple synthesis and separation in magnetic field, usability in heterogeneous systems and low toxicity. Possible syntheses, surface modifications and characteristics were described by Li et al 2013. This type of solid-phase extraction is being successfully used in various fields as health care, microbiology, biotechnologies or sample preconcentration in analytical chemistry. In this preliminary study we report on the preparation and application of magnetically separable sorbent with surface modified by C18 alkyl chain for purification of water contaminated by environmentally hazardous organic compounds. Magnetic cores were co-precipitated from Fe2+ and Fe3+ chlorides in alkalic aqueous solution. Surface of synthetized Fe3O4 was modified with SiO2 by tetraethylorthosilicate to assure physico-chemical stability. Furthermore, Fe3O4/SiO2 complex has been treated by C18 functional group, which provides good affinity towards hydrophobic substances in water. Efficiency of sorption under various conditions has been examined on benzene, toluene, ethylbenzene and xylenes (BTEX), compounds found in petroleum products which contaminate air, soil and groundwater near of store tanks. Sorption kinetics was followed by gas chromatography with mass spectrometry. The preliminary sorption kinetics data and efficiency of BTEX removal point at the possible application of prepared magnetic sorbent for BTEX removal, especially for ethylbenzene and xylenes.

  12. A very sensitive LSC procedure to determine Ni-63 in environmental samples, steel and concrete

    International Nuclear Information System (INIS)

    Scheuerer, C.; Schupfner, R.; Schuettelkopf, H.

    1995-01-01

    This procedure to determine Ni-63 contributes to a safe and economically reasonable decommissioning of nuclear power plants. Co-60, Fe-55 and Ni-63 are the most abundant long-lived radionuclides associated with contaminated piping, hardware and concrete for a period of several decades of years after shutdown. Samples are carefully ashed leached, or dissolved by suitable mixtures of acids. The analysis starts with the absorption Ni 2+ on the chelating resin CHELEX 100. The next purification steps include an anionic exchange column and a precipitation as Ni-dimethyl-glyoxime, which is extracted into chloroform. After reextraction with sulfuric acid the solution containing Ni 2+ is mixed with a scintillation cocktail and counted in an anticoincidence shielded LSC. The decontamination factors are determined for all important artificially and naturally occurring radionuclides ranging form above 10 4 to 10 9 . The chemical yield adopts a value of (95±5)%. Up to maximum sample amounts of 0.4 g steel, 5 g concrete and about 100 g of environmental samples the detection limits are about 5 mBq per sample or 12 mBq/g steel, 1 mBq/g concrete and 0.05 mBq/g environmental sample at a counting time of 1000 minutes. (author) 16 refs.; 2 figs.; 2 tabs

  13. Application of empore TM strontium rad disks to the analysis of radiostrontium in environmental water samples

    International Nuclear Information System (INIS)

    Smith, L.L.; Seely, D.C.; Shannon, R.T.

    1996-01-01

    A solid phase extraction method for analyzing radioactive strontium in surface, ground, and drinking waters is presented. Strontium is simply isolated by pulling an acidified sample aliquot through an Empore TM strontium rad disk with a vacuum, and the disk is subsequently assayed for beta activity. The method is efficient, safe, reliable, and potentially field deployable. Sample preparation and counting source preparation may be condensed into a single procedure, thereby improving efficiency and eliminating many potential sources of laboratory error. Moreover, many of the hazardous chemicals associated with traditional strontium procedures are eliminated. Samples are easily batched, and a one-liter sample may be prepared with as little as 20 min of effort. For a one-liter aqueous sample, up to 3 mg of strontium can be retained by the disks. Chemical and radiometric interferences are discussed. (orig.)

  14. Laboratory Studies on Surface Sampling of Bacillus anthracis Contamination: Summary, Gaps, and Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Hu, Rebecca

    2011-11-28

    This report summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing, and analyzing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe, and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Other key parameters include the ability to calculate, following contamination incidents, the (1) estimates of Bacillus anthracis contamination, as well as the bias and uncertainties in the estimates, and (2) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed and recommendations are given for future studies.

  15. Calculation of parameter failure probability of thermodynamic system by response surface and importance sampling method

    International Nuclear Information System (INIS)

    Shang Yanlong; Cai Qi; Chen Lisheng; Zhang Yangwei

    2012-01-01

    In this paper, the combined method of response surface and importance sampling was applied for calculation of parameter failure probability of the thermodynamic system. The mathematics model was present for the parameter failure of physics process in the thermodynamic system, by which the combination arithmetic model of response surface and importance sampling was established, then the performance degradation model of the components and the simulation process of parameter failure in the physics process of thermodynamic system were also present. The parameter failure probability of the purification water system in nuclear reactor was obtained by the combination method. The results show that the combination method is an effective method for the calculation of the parameter failure probability of the thermodynamic system with high dimensionality and non-linear characteristics, because of the satisfactory precision with less computing time than the direct sampling method and the drawbacks of response surface method. (authors)

  16. Apparatus for surface treatment of U-Pu carbide fuel samples

    International Nuclear Information System (INIS)

    Fukushima, Susumu; Arai, Yasuo; Handa, Muneo; Ohmichi, Toshihiko; Shiozawa, Ken-ichi.

    1979-05-01

    Apparatus has been constructed for treating the surface of U-Pu carbide fuel samples for EPMA. The treatment is to clean off oxide layer on the surface, then coat with an electric-conductive material. The apparatus, safe in handling plutonium, operates as follows. (1) To avoid oxidation of the analyzing surface by oxygen and water in the air, series of cleaning and coating, i.e. ion-etching and ion-coating or ion-etching and vacuum-evaporation is done at the same time in an inert gas atmosphere. (2) Ion-etching is possible on samples embedded in non-electric-conductive and low heat-conductive resin. (3) Since the temperature rise in (2) is negligible, there is no deterioration of the samples. (author)

  17. Accelerated sampling by infinite swapping of path integral molecular dynamics with surface hopping

    Science.gov (United States)

    Lu, Jianfeng; Zhou, Zhennan

    2018-02-01

    To accelerate the thermal equilibrium sampling of multi-level quantum systems, the infinite swapping limit of a recently proposed multi-level ring polymer representation is investigated. In the infinite swapping limit, the ring polymer evolves according to an averaged Hamiltonian with respect to all possible surface index configurations of the ring polymer and thus connects the surface hopping approach to the mean-field path-integral molecular dynamics. A multiscale integrator for the infinite swapping limit is also proposed to enable efficient sampling based on the limiting dynamics. Numerical results demonstrate the huge improvement of sampling efficiency of the infinite swapping compared with the direct simulation of path-integral molecular dynamics with surface hopping.

  18. Evaluation of the Environmental Supports Scale with a Community Sample of Adolescents.

    Science.gov (United States)

    Risco, Cristina M; Collado, Anahi D; Reynolds, Elizabeth K; Lejuez, Carl W; MacPherson, Laura

    2016-05-01

    Environmental sources of psychosocial support have been found to modulate or protect against the development of psychopathology and risk behavior among adolescents. Capturing sources of environmental support across multiple developmental contexts requires the availability of well-validated, concise assessments-of which there are few in the existing literature. In order to address this need, the current study explored the factor structure, concurrent and convergent validity of the Environmental Supports Scale (ESS; Genetic, Social, and General Psychology Monographs, 117; 395-417, 1991) with a community sample of adolescents. An unconstrained exploratory factor analysis revealed a separate factor for home, school, and neighborhood settings. Internal consistency and test-retest reliability were evaluated for each factor. Concurrent and predictive validity analyses revealed that the ESS was associated in the expected directions across a range of constructs relevant to adolescent development including internalizing symptoms, well-being, external influences, and engagement in risk behavior. Convergent validity for the neighborhood context was established with an assessment of neighborhood environmental adversity. A brief assessment of perceived environmental support across key developmental contexts provides an important tool for research on resilience processes during adolescence and may help illuminate key protective factors and inform intervention and prevention efforts.

  19. New developments in the extraction and determination of parabens in cosmetics and environmental samples. A review

    International Nuclear Information System (INIS)

    Ocaña-González, Juan Antonio; Villar-Navarro, Mercedes; Ramos-Payán, María; Fernández-Torres, Rut; Bello-López, Miguel Angel

    2015-01-01

    Highlights: • The analysis of parabens in cosmetics and environmental samples is reviewed. • Literature in this field from 1980 to 2003 is briefly discussed. • Determination and extraction methods in the last decade are discussed in-depth. - Abstract: Parabens are a family of synthetic esters of p-hydroxibenzoic acid widely used as preservatives in cosmetics and health-care products, among other daily-use commodities. Recently, their potential endocrine disrupting effects have raised concerns about their safety and their potential effects as emerging pollutants, leading to the regulation of the presence of parabens in commercial products by national and trans-national organizations. Also, this has led to an interest in developing sensible and reliable methods for their determination in environmental samples, cosmetics and health-care products. This paper is a comprehensive up-to-date review of the literature concerning the determination of parabens in environmental samples and cosmetic and health-care products. A brief revision of the literature concerning the traditional determination of parabens (1980–2003) is included, followed by an in-depth revision of the recent developments in both measurement and extraction methods for parabens in the last years (2003–2013). Finally, possible future perspectives in this field are proposed

  20. New developments in the extraction and determination of parabens in cosmetics and environmental samples. A review

    Energy Technology Data Exchange (ETDEWEB)

    Ocaña-González, Juan Antonio; Villar-Navarro, Mercedes [Department of Analytical Chemistry, Faculty of Chemistry, Universidad de Sevilla, c/Prof. García González, s/n. 41012 Seville (Spain); Ramos-Payán, María [Department of Analytical Chemistry, Faculty of Chemistry, Universidad de Sevilla, c/Prof. García González, s/n. 41012 Seville (Spain); Department of Analytical Chemistry, Lineberguer Cancer Center, The University of North Carolina at Chapel Hill, NC (United States); Fernández-Torres, Rut [Department of Analytical Chemistry, Faculty of Chemistry, Universidad de Sevilla, c/Prof. García González, s/n. 41012 Seville (Spain); Research Centre of Health and Environment (CYSMA), University of Huelva (Spain); Bello-López, Miguel Angel, E-mail: mabello@us.es [Department of Analytical Chemistry, Faculty of Chemistry, Universidad de Sevilla, c/Prof. García González, s/n. 41012 Seville (Spain)

    2015-02-09

    Highlights: • The analysis of parabens in cosmetics and environmental samples is reviewed. • Literature in this field from 1980 to 2003 is briefly discussed. • Determination and extraction methods in the last decade are discussed in-depth. - Abstract: Parabens are a family of synthetic esters of p-hydroxibenzoic acid widely used as preservatives in cosmetics and health-care products, among other daily-use commodities. Recently, their potential endocrine disrupting effects have raised concerns about their safety and their potential effects as emerging pollutants, leading to the regulation of the presence of parabens in commercial products by national and trans-national organizations. Also, this has led to an interest in developing sensible and reliable methods for their determination in environmental samples, cosmetics and health-care products. This paper is a comprehensive up-to-date review of the literature concerning the determination of parabens in environmental samples and cosmetic and health-care products. A brief revision of the literature concerning the traditional determination of parabens (1980–2003) is included, followed by an in-depth revision of the recent developments in both measurement and extraction methods for parabens in the last years (2003–2013). Finally, possible future perspectives in this field are proposed.

  1. Application of ICP-MS in Environmental Sampling Analysis for Safeguards

    International Nuclear Information System (INIS)

    Eko Pudjadi; Petrus Zacharias; Budi Prayitno

    2004-01-01

    Environmental samples measured by ICP-MS were analyzed for safeguards. There are two isotopes in environmental sampling that is used to find out the origin of nuclear materials and verify undeclared nuclear activities. Uranium isotopes are 234 U, 235 U, 236 U and 238 U and Plutonium isotopes are 239 Pu, 240 Pu, 241 Pu and 242 Pu. Uranium isotopes are used to verify an existing of nuclear power plants, enrichment plants or reprocessing plants. Plutonium isotopes are used to clarify global fallout from nuclear weapon testing and accident of nuclear facility or military purposes. The high sensitivity of ICP-MS can detect the isotopic fingerprint and trace elements in ppb concentration; ICP-MS has been applied to measure 235 U isotopic ratio and 240 Pu/ 239 Pu isotopic ratios. The sensitivity of ICP-MS is high precision and low operational cost in environmental sampling and can be considered in nuclear power design based on safeguards for development countries. (author)

  2. Recovery of diverse microbes in high turbidity surface water samples using dead-end ultrafiltration.

    Science.gov (United States)

    Mull, Bonnie; Hill, Vincent R

    2012-12-01

    Dead-end ultrafiltration (DEUF) has been reported to be a simple, field-deployable technique for recovering bacteria, viruses, and parasites from large-volume water samples for water quality testing and waterborne disease investigations. While DEUF has been reported for application to water samples having relatively low turbidity, little information is available regarding recovery efficiencies for this technique when applied to sampling turbid water samples such as those commonly found in lakes and rivers. This study evaluated the effectiveness of a DEUF technique for recovering MS2 bacteriophage, enterococci, Escherichia coli, Clostridium perfringens, and Cryptosporidium parvum oocysts in surface water samples having elevated turbidity. Average recovery efficiencies for each study microbe across all turbidity ranges were: MS2 (66%), C. parvum (49%), enterococci (85%), E. coli (81%), and C. perfringens (63%). The recovery efficiencies for MS2 and C. perfringens exhibited an inversely proportional relationship with turbidity, however no significant differences in recovery were observed for C. parvum, enterococci, or E. coli. Although ultrafilter clogging was observed, the DEUF method was able to process 100-L surface water samples at each turbidity level within 60 min. This study supports the use of the DEUF method for recovering a wide array of microbes in large-volume surface water samples having medium to high turbidity. Published by Elsevier B.V.

  3. Effects of Spatial Sampling Interval on Roughness Parameters and Microwave Backscatter over Agricultural Soil Surfaces

    Directory of Open Access Journals (Sweden)

    Matías Ernesto Barber

    2016-06-01

    Full Text Available The spatial sampling interval, as related to the ability to digitize a soil profile with a certain number of features per unit length, depends on the profiling technique itself. From a variety of profiling techniques, roughness parameters are estimated at different sampling intervals. Since soil profiles have continuous spectral components, it is clear that roughness parameters are influenced by the sampling interval of the measurement device employed. In this work, we contributed to answer which sampling interval the profiles needed to be measured at to accurately account for the microwave response of agricultural surfaces. For this purpose, a 2-D laser profiler was built and used to measure surface soil roughness at field scale over agricultural sites in Argentina. Sampling intervals ranged from large (50 mm to small ones (1 mm, with several intermediate values. Large- and intermediate-sampling-interval profiles were synthetically derived from nominal, 1 mm ones. With these data, the effect of sampling-interval-dependent roughness parameters on backscatter response was assessed using the theoretical backscatter model IEM2M. Simulations demonstrated that variations of roughness parameters depended on the working wavelength and was less important at L-band than at C- or X-band. In any case, an underestimation of the backscattering coefficient of about 1-4 dB was observed at larger sampling intervals. As a general rule a sampling interval of 15 mm can be recommended for L-band and 5 mm for C-band.

  4. Rapid Surface Sampling and Archival Record (RSSAR) system. Final report, October 1995--May 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    This report describes the results of Phase 2 efforts to develop a Rapid Surface Sampling and Archival Record (RSSAR) System for the detection of semivolatile organic contaminants on concrete, transite, and metal surfaces. The characterization of equipment and building surfaces for the presence of contaminants as part of building decontamination and decommissioning activities is an immensely large task of concern to both government and industry. Because of the high cost of hazardous waste disposal, old, contaminated buildings cannot simply be demolished and scrapped. Contaminated and clean materials must be clearly identified and segregated so that the clean material can be recycled or reused, if possible, or disposed of more cheaply as nonhazardous waste. DOE has a number of sites requiring surface characterization. These sites are large, contain very heterogeneous patterns of contamination (requiring high sampling density), and will thus necessitate an enormous number of samples to be taken and analyzed. Characterization of building and equipment surfaces will be needed during initial investigations, during cleanup operations, and during the final confirmation process, increasing the total number of samples well beyond that needed for initial characterization. This multiplicity of information places a premium on the ability to handle and track data as efficiently as possible.

  5. Rapid Surface Sampling and Archival Record (RSSAR) system. Final report, October 1995 - May 1997

    International Nuclear Information System (INIS)

    1998-01-01

    This report describes the results of Phase 2 efforts to develop a Rapid Surface Sampling and Archival Record (RSSAR) System for the detection of semivolatile organic contaminants on concrete, transite, and metal surfaces. The characterization of equipment and building surfaces for the presence of contaminants as part of building decontamination and decommissioning activities is an immensely large task of concern to both government and industry. Because of the high cost of hazardous waste disposal, old, contaminated buildings cannot simply be demolished and scrapped. Contaminated and clean materials must be clearly identified and segregated so that the clean material can be recycled or reused, if possible, or disposed of more cheaply as nonhazardous waste. DOE has a number of sites requiring surface characterization. These sites are large, contain very heterogeneous patterns of contamination (requiring high sampling density), and will thus necessitate an enormous number of samples to be taken and analyzed. Characterization of building and equipment surfaces will be needed during initial investigations, during cleanup operations, and during the final confirmation process, increasing the total number of samples well beyond that needed for initial characterization. This multiplicity of information places a premium on the ability to handle and track data as efficiently as possible

  6. Onondaga Lake: A Forsaken Superfund Site, or a Sampling Playground for Environmental Geochemistry Classes?

    Science.gov (United States)

    Karmosky, C. C.; Harpp, K. S.

    2004-05-01

    Onondaga Lake, in Syracuse, NY, is described by the EPA as one of the most polluted lakes in the US. High levels of heavy metal and semi-volatile organic contamination provide an excellent case study that serves as the cornerstone for an environmental geochemistry course at Colgate University. Our course is designed to teach students basic environmental analysis skills including experimental design, sample preparation, analytical instrumentation operation, data processing and statistical analysis, and preparation of a collaborative scientific paper. Participating students generally have some background in environmental geology, but rarely more than one semester of chemistry. The Onondaga Lake project is the focus of the course for approximately half the semester. At the outset of the project, students are presented with a driving question that is answered through a series of guided field and lab investigations, such as an assessment of the environmental consequences of a proposed marina along the lakefront. The students' first task is to delve into the lake's environmental history, including identification of contaminants, location of point and non-point pollution sources, and clean-up efforts. Students then participate in 2 field trips to the site. First, students learn the geography of the lake system, collect sediment and water samples, and observe mitigation efforts at the wastewater treatment plant. The second trip is 2-3 weeks later, after students have assessed further sampling needs. Identification and quantification of organic compounds are accomplished by GC-MS, and heavy metal contents are determined by ICP-MS. Students compile their results, perform statistical analyses, and collaboratively draw their conclusions regarding the impact of the proposed project. The final product is a single report written by the entire class, an exercise in organization, cooperation, and planning that is usually the most challenging, but ultimately the most rewarding

  7. Assessment of an action against environmental noise: Acoustic durability of a pavement surface with crumb rubber.

    Science.gov (United States)

    Vázquez, V F; Luong, J; Bueno, M; Terán, F; Paje, S E

    2016-01-15

    Environmental noise is a worldwide problem that has an adverse effect in the quality of life of urban population. Some work has shown that there is a correlation between environmental noise and health issues as sleep disturbance or annoyance. This study presents the time evolution of a test track fabricated with an asphalt mixture with 20% of crumb rubber by weight of bitumen, added by the wet process. A complete surface characterization has been performed by determining tire/pavement sound levels, road texture profiles, in-situ dynamic stiffness and sound absorption of compacted and extracted sample cores. Two measurement campaigns were performed: just after mixture laying and after 3 years in service. This study confirms that the use of crumb rubber as a modifier of bituminous binders (CRMB) can improve the pavement characteristics: gap-graded mixtures with crumb rubber can be used in the action plans as urban rehabilitation measure to fight noise pollution. However, this noise reduction seems to decrease with age at a rate of approximately 0.15 dB(A) per year. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Salmonella isolated from individual reptiles and environmental samples from terraria in private households in Sweden.

    Science.gov (United States)

    Wikström, Veronica O; Fernström, Lise-Lotte; Melin, Lennart; Boqvist, Sofia

    2014-01-24

    This study investigates Salmonella spp. isolated from privately kept reptiles and from environmental samples such as bedding materials or water from the floor of the enclosures (terraria). It also compares isolation of Salmonella using Modified Semisolid Rappaport-Vassiliadis (MSRV) medium or selective enrichment in Rappaport-Vassiliadis-Soya (RVS) pepton broth. Cloacal swabs or swabs from the cloacal area were collected from 63 individual reptiles belonging to 14 households. All reptiles were from different terraria and from 62 of these, environmental samples were also collected. Sampling were done by the reptile owners according to written instructions and sent by mail immediately after sampling. All but three samples were analyzed within 24 h after collection. Colonies suspected for Salmonella were tested for agglutination and serotyped using the White-Kauffmann-Le Minor scheme. The relative sensitivity (se) and specificity (sp) for MSRV compared with RVS, and the agreement coefficient kappa (κ) were calculated. Salmonella was isolated from 50/63 (80%) terraria, either from the reptiles (31/63; 49%) or from bedding material (39/62; 63%). The most common subspecies was Salmonella enterica subspecies enterica followed by S. enterica subspecies diarizonae. In reptiles, the most common S. enterica subspecies enterica serovars were Java (n = 4) and Fluntern (n = 4), compared with the serovars Tennessee (n = 10) and Fluntern (n = 10) in the environmental samples. The exact same set of Salmonella subspecies and serovars were not isolated from the individual reptiles and the environmental samples from any of the households. Isolation using MSRV yielded more Salmonella isolates 61/113 (54%) than enrichment in RVS 57/125 (46%). The se was 97.9% (95% Confidence Interval 93.9-100), the sp 78.5% (95% CI 68.5-88.5) and the κ 0.74, indicating substantial agreement between the tests. Salmonella can be expected to be present in environments where reptiles are

  9. Determination of submicrogram-per-liter concentrations of caffeine in surface water and groundwater samples by solid-phase extraction and liquid chromatography

    Science.gov (United States)

    Burkhardt, M.R.; Soliven, P.P.; Werner, S.L.; Vaught, D.G.

    1999-01-01

    A method for determining submicrogram-per-liter concentrations of caffeine in surface water and groundwater samples has been developed. Caffeine is extracted from a 1 L water sample with a 0.5 g graphitized carbon-based solid-phase cartridge, eluted with methylene chloride-methanol (80 + 20, v/v), and analyzed by liquid chromatography with photodiode-array detection. The single-operator method detection limit for organic-free water samples was 0.02 ??g/L. Mean recoveries and relative standard deviations were 93 ?? 13% for organicfree water samples fortified at 0.04 ??g/L and 84 ?? 4% for laboratory reagent spikes fortified at 0.5 ??g/L. Environmental concentrations of caffeine ranged from 0.003 to 1.44 ??g/L in surface water samples and from 0.01 to 0.08 ??g/L in groundwater samples.

  10. Surface characterization of Nb samples electropolished with real superconducting rf accelerator cavities

    Directory of Open Access Journals (Sweden)

    Xin Zhao

    2010-12-01

    Full Text Available We report the results of surface characterizations of niobium (Nb samples electropolished together with a single cell superconducting radio-frequency accelerator cavity. These witness samples were located in three regions of the cavity, namely at the equator, the iris, and the beam pipe. Auger electron spectroscopy was utilized to probe the chemical composition of the topmost four atomic layers. Scanning electron microscopy with energy dispersive x ray for elemental analysis was used to observe the surface topography and chemical composition at the micrometer scale. A few atomic layers of sulfur (S were found covering the samples nonuniformly. Niobium oxide granules with a sharp geometry were observed on every sample. Some Nb-O granules appeared to also contain sulfur.

  11. Enhanced propellant performance via environmentally friendly curable surface coating

    Directory of Open Access Journals (Sweden)

    Thelma Manning

    2017-06-01

    Full Text Available Surface coating of granular propellants is widely used in a multiplicity of propellants for small, medium and large caliber ammunition. All small caliber ball propellants exhibit burning progressivity due to application of effective deterrent coatings. Large perforated propellant grains have also begun utilizing plasticizing and impregnated deterrent coatings with the purpose of increasing charge weights for greater energy and velocity for the projectile. The deterrent coating and impregnation process utilizes volatile organic compounds (VOCs and hazardous air pollutants (HAPs which results in propellants that need to be forced air dried which impacts air quality. Propellants undergo temperature fluctuations during their life. Diffusion coefficients vary exponentially with variations in temperature. A small temperature increase can induce a faster migration, even over a short period of time, which can lead to large deviations in the concentration. This large concentration change in the ammunition becomes a safety or performance liability. The presence of both polymeric deterrents and nitroglycerin(NG in the nitrocellulose matrix and organic solvents leads to higher diffusion rates. This results in continued emissions of VOCs and HAPs. Conventional polymers tend to partition within the propellant matrix. In other words, localized mixing can occur between the polymer and underlying propellant. This is due to solvent induced softening of the polymer vehicle over the propellant grain. In effect this creates a path where migration can occur. Since nitrate esters, like NG, are relatively small, it can exude to the surface and create a highly unstable and dangerous situation for the warfighter. Curable polymers do not suffer from this partitioning due to “melting” because no VOC solvents are present. They remain surface coated. The small scale characterization testing, such as closed bomb testing, small scale sensitivity, thermal stability, and

  12. Effects of surface roughness, texture and polymer degradation on cathodic delamination of epoxy coated steel samples

    International Nuclear Information System (INIS)

    Khun, N.W.; Frankel, G.S.

    2013-01-01

    Highlights: ► Cathodic delamination of epoxy coated steel samples was studied using SKP. ► Delamination of the coating decreased with increased substrate surface roughness. ► Delamination of the coating was faster on the substrate with parallel surface scratches. ► Delamination of the coating exposed to weathering conditions increased with prolonged exposure. - Abstract: The Scanning Kelvin Probe (SKP) technique was used to investigate the effects of surface roughness, texture and polymer degradation on cathodic delamination of epoxy coated steel. The cathodic delamination rate of the epoxy coatings dramatically decreased with increased surface roughness of the underlying steel substrate. The surface texture of the steel substrates also had a significant effect in that samples with parallel abrasion lines exhibiting faster cathodic delamination in the direction of the lines compared to the direction perpendicular to the lines. The cathodic delamination kinetics of epoxy coatings previously exposed to weathering conditions increased with prolonged exposure due to pronounced polymer degradation. SEM observation confirmed that the cyclic exposure to UV radiation and water condensation caused severe deterioration in the polymer structures with surface cracking and erosion. The SKP results clearly showed that the cathodic delamination of the epoxy coatings was significantly influenced by the surface features of the underlying steel substrates and the degradation of the coatings.

  13. Surface analyses of electropolished niobium samples for superconducting radio frequency cavity

    International Nuclear Information System (INIS)

    Tyagi, P. V.; Nishiwaki, M.; Saeki, T.; Sawabe, M.; Hayano, H.; Noguchi, T.; Kato, S.

    2010-01-01

    The performance of superconducting radio frequency niobium cavities is sometimes limited by contaminations present on the cavity surface. In the recent years extensive research has been done to enhance the cavity performance by applying improved surface treatments such as mechanical grinding, electropolishing (EP), chemical polishing, tumbling, etc., followed by various rinsing methods such as ultrasonic pure water rinse, alcoholic rinse, high pressure water rinse, hydrogen per oxide rinse, etc. Although good cavity performance has been obtained lately by various post-EP cleaning methods, the detailed nature about the surface contaminants is still not fully characterized. Further efforts in this area are desired. Prior x-ray photoelectron spectroscopy (XPS) analyses of EPed niobium samples treated with fresh EP acid, demonstrated that the surfaces were covered mainly with the niobium oxide (Nb 2 O 5 ) along with carbon, in addition a small quantity of sulfur and fluorine were also found in secondary ion mass spectroscopy (SIMS) analysis. In this article, the authors present the analyses of surface contaminations for a series of EPed niobium samples located at various positions of a single cell niobium cavity followed by ultrapure water rinsing as well as our endeavor to understand the aging effect of EP acid solution in terms of contaminations presence at the inner surface of the cavity with the help of surface analytical tools such as XPS, SIMS, and scanning electron microscope at KEK.

  14. Surface analyses of electropolished niobium samples for superconducting radio frequency cavity

    Energy Technology Data Exchange (ETDEWEB)

    Tyagi, P. V.; Nishiwaki, M.; Saeki, T.; Sawabe, M.; Hayano, H.; Noguchi, T.; Kato, S. [GUAS, Tsukuba, Ibaraki 305-0801 (Japan); KEK, Tsukuba, Ibaraki 305-0801 (Japan); KAKEN Inc., Hokota, Ibaraki 311-1416 (Japan); GUAS, Tsukuba, Ibaraki 305-0801 (Japan) and KEK, Tsukuba, Ibaraki 305-0801 (Japan)

    2010-07-15

    The performance of superconducting radio frequency niobium cavities is sometimes limited by contaminations present on the cavity surface. In the recent years extensive research has been done to enhance the cavity performance by applying improved surface treatments such as mechanical grinding, electropolishing (EP), chemical polishing, tumbling, etc., followed by various rinsing methods such as ultrasonic pure water rinse, alcoholic rinse, high pressure water rinse, hydrogen per oxide rinse, etc. Although good cavity performance has been obtained lately by various post-EP cleaning methods, the detailed nature about the surface contaminants is still not fully characterized. Further efforts in this area are desired. Prior x-ray photoelectron spectroscopy (XPS) analyses of EPed niobium samples treated with fresh EP acid, demonstrated that the surfaces were covered mainly with the niobium oxide (Nb{sub 2}O{sub 5}) along with carbon, in addition a small quantity of sulfur and fluorine were also found in secondary ion mass spectroscopy (SIMS) analysis. In this article, the authors present the analyses of surface contaminations for a series of EPed niobium samples located at various positions of a single cell niobium cavity followed by ultrapure water rinsing as well as our endeavor to understand the aging effect of EP acid solution in terms of contaminations presence at the inner surface of the cavity with the help of surface analytical tools such as XPS, SIMS, and scanning electron microscope at KEK.

  15. Adaptive Sampling based 3D Profile Measuring Method for Free-Form Surface

    Science.gov (United States)

    Duan, Xianyin; Zou, Yu; Gao, Qiang; Peng, Fangyu; Zhou, Min; Jiang, Guozhang

    2018-03-01

    In order to solve the problem of adaptability and scanning efficiency of the current surface profile detection device, a high precision and high efficiency detection approach is proposed for surface contour of free-form surface parts based on self- adaptability. The contact mechanical probe and the non-contact laser probe are synthetically integrated according to the sampling approach of adaptive front-end path detection. First, the front-end path is measured by the non-contact laser probe, and the detection path is planned by the internal algorithm of the measuring instrument. Then a reasonable measurement sampling is completed according to the planned path by the contact mechanical probe. The detection approach can effectively improve the measurement efficiency of the free-form surface contours and can simultaneously detect the surface contours of unknown free-form surfaces with different curvatures and even different rate of curvature. The detection approach proposed in this paper also has important reference value for free-form surface contour detection.

  16. 210Pb and 210Po determination in environmental samples using liquid scintillation counting and alpha spectrometry

    International Nuclear Information System (INIS)

    Perez Sanchez, D.; Martin Sanchez, A.; Jurado Vargas, M.

    2003-01-01

    A simple radiochemical procedure has been developed to determine 210 Pb and 210 Po in environmental samples from the same matrix. Sediment samples are decomposed by leaching with mineral acids or by microwave digestion, while water samples are pre-concentrated. One part of the resulting solution, spiked with 209 Po, is used for 210 Po determination by spontaneous deposition onto nickel disks (a-spectrometry). The other part is assayed for 210 Pb, separating the Pb either by anion-exchange (sediment samples), or by solvent extraction (water samples). The 210 Pb source is finally prepared by precipitation as oxalate and the chemical recovery determined by gravimetry. The 210 Pb activity concentration is determined by liquid scintillation. A standard sediment sample supplied by IAEA and spiked water samples were analysed to check the procedure. The 210 Pb and 210 Po measurements agreed well with the certifications, deviations being less than 10%. The mean recoveries for Pb and Po were (70±12)% and (77±8)% for sediments, and (70±10)% and (81±7)% for waters, respectively. (author)

  17. Preparation Of Deposited Sediment Sample By Casting Method For Environmental Study

    International Nuclear Information System (INIS)

    Hutabarat, Tommy; Ristin PI, Evarista

    2000-01-01

    The preparation of deposited sediment sample by c asting m ethod for environmental study has been carried out. This method comprises separation of size fraction and casting process. The deposited sediment samples were wet sieved to separate the size fraction of >500 mum, (250-500) mum, (125-250) mum and (63-125) mum and settling procedures were followed for the separation of (40-63) mum, (20-40) mum, (10-20) mum and o C, ashed at 450 o C, respectively. In the casting process of sample, it was used polyester rapid cure resin and methyl ethyl ketone peroxide (MEKP) hardener. The moulded sediment sample was poured onto caster, allow for 60 hours long. The aim of this method is to get the casted sample which can be used effectively, efficiently and to be avoided from contamination of each other samples. Before casting, samples were grinded up to be fine. The result shows that casting product is ready to be used for natural radionuclide analysis

  18. An Overview of Pesticide Monitoring at Environmental Samples Using Carbon Nanotubes-Based Electrochemical Sensors

    Directory of Open Access Journals (Sweden)

    Ademar Wong

    2017-03-01

    Full Text Available Carbon nanotubes have received enormous attention in the development of electrochemical sensors by promoting electron transfer reactions, decreasing the work overpotential within great surface areas. The growing concerns about environmental health emphasized the necessity of continuous monitoring of pollutants. Pesticides have been successfully used to control agricultural and public health pests; however, intense use can cause a number of damages for biodiversity and human health. In this sense, carbon nanotubes-based electrochemical sensors have been proposed for pesticide monitoring combining different electrode modification strategies and electroanalytical techniques. In this paper, we provide a review of the recent advances in the use of carbon nanotubes for the construction of electrochemical sensors dedicated to the environmental monitoring of pesticides. Future directions, perspectives, and challenges are also commented.

  19. Vibrio parahaemolyticus Strains of Pandemic Serotypes Identified from Clinical and Environmental Samples from Jiangsu, China

    Directory of Open Access Journals (Sweden)

    Jingjiao eLi

    2016-05-01

    Full Text Available Vibrio parahaemolyticus has emerged as a major foodborne pathogen in China, Japan, Thailand and other Asian countries. In this study, 72 strains of V. parahaemolyticus were isolated from clinical and environmental samples between 2006 and 2014 in Jiangsu, China. The serotypes and six virulence genes including thermostable direct hemolysin (TDR and TDR-related hemolysin (TRH genes were assessed among the isolates. Twenty five serotypes were identified and O3:K6 was one of the dominant serotypes. The genetic diversity was assessed by multilocus sequence typing (MLST analysis, and 48 sequence types (STs were found, suggesting this V. parahaemolyticus group is widely dispersed and undergoing rapid evolution. A total of 25 strains of pandemic serotypes such as O3:K6, O5:K17 and O1:KUT were identified. It is worth noting that the pandemic serotypes were not exclusively identified from clinical samples, rather, nine strains were also isolated from environmental samples; and some of these strains harbored several virulence genes, which may render those strains pathogenicity potential. Therefore, the emergence of these environmental pandemic V. parahaemolyticus strains may poses a new threat to the public health in China. Furthermore, six novel serotypes and 34 novel STs were identified among the 72 isolates, indicating that V. parahaemolyticus were widely distributed and fast evolving in the environment in Jiangsu, China. The findings of this study provide new insight into the phylogenic relationship between V. parahaemolyticus strains of pandemic serotypes from clinical and environmental sources and enhance the MLST database; and our proposed possible O- and K- antigen evolving paths of V. parahaemolyticus may help understand how the serotypes of this dispersed bacterial population evolve.

  20. Dehalococcoides as a Potential Biomarker Evidence for Uncharacterized Organohalides in Environmental Samples

    Directory of Open Access Journals (Sweden)

    Qihong Lu

    2017-09-01

    Full Text Available The massive production and improper disposal of organohalides resulted in worldwide contamination in soil and water. However, their environmental survey based on chromatographic methods was hindered by challenges in testing the extremely wide variety of organohalides. Dehalococcoides as obligate organohalide-respiring bacteria exclusively use organohalides as electron acceptors to support their growth, of which the presence could be coupled with organohalides and, therefore, could be employed as a biomarker of the organohalide pollution. In this study, Dehalococcoides was screened in various samples of bioreactors and subsurface environments, showing the wide distribution of Dehalococcoides in sludge and sediment. Further laboratory cultivation confirmed the dechlorination activities of those Dehalococcoides. Among those samples, Dehalococcoides accounting for 1.8% of the total microbial community was found in an anaerobic granular sludge sample collected from a full-scale bioreactor treating petroleum wastewater. Experimental evidence suggested that the influent wastewater in the bioreactor contained bromomethane which support the growth of Dehalococcoides. This study demonstrated that Dehalococcoides could be employed as a promising biomarker to test the present of organohalides in wastestreams or other environmental samples.